WorldWideScience

Sample records for oxygen intake vo2

  1. Improving the Accuracy of Predicting Maximal Oxygen Consumption (VO2pk)

    Science.gov (United States)

    Downs, Meghan E.; Lee, Stuart M. C.; Ploutz-Snyder, Lori; Feiveson, Alan

    2016-01-01

    Maximal oxygen (VO2pk) is the maximum amount of oxygen that the body can use during intense exercise and is used for benchmarking endurance exercise capacity. The most accurate method to determineVO2pk requires continuous measurements of ventilation and gas exchange during an exercise test to maximal effort, which necessitates expensive equipment, a trained staff, and time to set-up the equipment. For astronauts, accurate VO2pk measures are important to assess mission critical task performance capabilities and to prescribe exercise intensities to optimize performance. Currently, astronauts perform submaximal exercise tests during flight to predict VO2pk; however, while submaximal VO2pk prediction equations provide reliable estimates of mean VO2pk for populations, they can be unacceptably inaccurate for a given individual. The error in current predictions and logistical limitations of measuring VO2pk, particularly during spaceflight, highlights the need for improved estimation methods.

  2. Factors determining the oxygen consumption rate (VO2) on-kinetics in skeletal muscles.

    Science.gov (United States)

    Korzeniewski, Bernard; Zoladz, Jerzy A

    2004-05-01

    Using a computer model of oxidative phosphorylation developed previously [Korzeniewski and Mazat (1996) Biochem. J. 319, 143-148; Korzeniewski and Zoladz (2001) Biophys. Chem. 92, 17-34], we analyse the effect of several factors on the oxygen-uptake kinetics, especially on the oxygen consumption rate (VO2) and half-transition time t(1/2), at the onset of exercise in skeletal muscles. Computer simulations demonstrate that an increase in the total creatine pool [PCr+/-Cr] (where Cr stands for creatine and PCr for phosphocreatine) and in glycolytic ATP supply lengthen the half-transition time, whereas increase in mitochondrial content, in parallel activation of ATP supply and ATP usage, in oxygen concentration, in proton leak, in resting energy demand, in resting cytosolic pH and in initial alkalization decrease this parameter. Theoretical studies show that a decrease in the activity of creatine kinase (CK) [displacement of this enzyme from equilibrium during on-transient (rest-to-work transition)] accelerates the first stage of the VO2 on-transient, but slows down the second stage of this transient. It is also demonstrated that a prior exercise terminated a few minutes before the principal exercise shortens the transition time. Finally, it is shown that at a given ATP demand, and under conditions where CK works near the thermodynamic equilibrium, the half-transition time of VO2 kinetics is determined by the amount of PCr that has to be transformed into Cr during rest-to-work transition; therefore any factor that diminishes the difference in [PCr] between rest and work at a given energy demand will accelerate the VO2 on-kinetics. Our conclusions agree with the general idea formulated originally by Easterby [(1981) Biochem. J. 199, 155-161] that changes in metabolite concentrations determine the transition times between different steady states in metabolic systems.

  3. Stoichiometric and Oxygen-Deficient VO2 as Versatile Hole Injection Electrode for Organic Semiconductors.

    Science.gov (United States)

    Fu, Keke; Wang, Rongbin; Katase, Takayoshi; Ohta, Hiromichi; Koch, Norbert; Duhm, Steffen

    2018-03-28

    Using photoemission spectroscopy, we show that the surface electronic structure of VO 2 is determined by the temperature-dependent metal-insulator phase transition and the density of oxygen vacancies, which depends on the temperature and ultrahigh vacuum (UHV) conditions. The atomically clean and stoichiometric VO 2 surface is insulating at room temperature and features an ultrahigh work function of up to 6.7 eV. Heating in UHV just above the phase transition temperature induces the expected metallic phase, which goes in hand with the formation of oxygen defects (up to 6% in this study), but a high work function >6 eV is maintained. To demonstrate the suitability of VO 2 as hole injection contact for organic semiconductors, we investigated the energy-level alignment with the prototypical organic hole transport material N, N'-di(1-naphthyl)- N, N'-diphenyl-(1,1'-biphenyl)-4,4'-diamine (NPB). Evidence for strong Fermi-level pinning and the associated energy-level bending in NPB is found, rendering an Ohmic contact for holes.

  4. Factors determining the oxygen consumption rate (VO2) on-kinetics in skeletal muscles.

    OpenAIRE

    Korzeniewski, Bernard; Zoladz, Jerzy A

    2004-01-01

    Using a computer model of oxidative phosphorylation developed previously [Korzeniewski and Mazat (1996) Biochem. J. 319, 143-148; Korzeniewski and Zoladz (2001) Biophys. Chem. 92, 17-34], we analyse the effect of several factors on the oxygen-uptake kinetics, especially on the oxygen consumption rate (VO2) and half-transition time t(1/2), at the onset of exercise in skeletal muscles. Computer simulations demonstrate that an increase in the total creatine pool [PCr+/-Cr] (where Cr stands for c...

  5. Physiological background of the change point in VO2 and the slow component of oxygen uptake kinetics.

    Science.gov (United States)

    Zoładź, J A; Korzeniewski, B

    2001-06-01

    It is generally believed that oxygen uptake during incremental exercise--until VO2max, increases linearly with power output (see eg. Astrand & Rodahl, 1986). On the other hand, it is well established that the oxygen uptake reaches a steady state only during a low power output exercise, but during a high power output exercise, performed above the lactate threshold (LT), the oxygen uptake shows a continuous increase until the end of the exercise. This effect has been called the slow component of VO2 kinetics (Whipp & Wasserman, 1972). The presence of a slow component in VO2 kinetics implies that during an incremental exercise test, after the LT has been exceeded, the VO2 to power output relationship has to become curvilinear. Indeed, it has recently been shown that during the incremental exercise, the exceeding of the power output, at which blood lactate begins to accumulate (LT), causes a non-proportional increase in VO2 (Zoladz et al. 1995) which indicates a drop in muscle mechanical efficiency. The power output at which VO2 starts to rise non-proportionally to the power output has been called "the change point in VO2" (Zoladz et al. 1998). In this paper, the significance of the factors most likely involved in the physiological mechanism responsible for the change point in oxygen uptake (CP-VO2) and for the slow component of VO2 kinetics, including: increase of activation of additional muscle groups, intensification of the respiratory muscle activity, recruitment of type II muscle fibres, increase of muscle temperature, increase of the basal metabolic rate, lactate and hydrogen ion accumulation, proton leak through the inner mitochondrial membrane, slipping of the ATP synthase and a decrease in the cytosolic phosphorylation potential, are discussed. Finally, an original own model describing the sequence of events leading to the non-proportional increase of oxygen cost of work at a high exercise intensity is presented.

  6. Relation of oxygen uptake to work rate in prepubertal healthy children - reference for VO2/W-slope and effect on cardiorespiratory fitness assessment.

    Science.gov (United States)

    Tompuri, Tuomo; Lintu, Niina; Laitinen, Tomi; Lakka, Timo A

    2017-08-09

    Exercise testing by cycle ergometer allows to observe the interaction between oxygen uptake (VO 2 ) and workload (W), and VO 2 /W-slope can be used as a diagnostic tool. Respectively, peak oxygen uptake (VO 2 PEAK ) can be estimated by maximal workload. We aim to determine reference for VO 2 /W-slope among prepubertal children and define agreement between estimated and measured VO 2 PEAK . A total of 38 prepubertal children (20 girls) performed a maximal cycle ergometer test with respiratory gas analysis. VO 2 /W-slopes were computed using linear regression. Agreement analysis by Bland and Altman for estimated and measured VO 2 PEAK was carried out including limits of agreement (LA). Determinants for VO 2 /W-slopes and estimation bias were defined. VO2/W-slope was in both girls and boys ≥9·4 and did not change with exercise level, but the oxygen cost of exercise was higher among physically more active children. Estimated VO 2 PEAK had 6·4% coefficient of variation, and LA varied from 13% underestimation to 13% overestimation. Bias had a trend towards underestimation along lean mass proportional VO 2 PEAK . The primary determinant for estimation bias was VO2/W-slope (β = -0·65; PW-slope among healthy prepubertal children were similar to those published for adults and among adolescents. Estimated and measured VO 2 PEAK should not be considered to be interchangeable because of the variation in the relationship between VO 2 and W. On other hand, variation in the relationship between VO 2 and W enables that VO 2 /W-slope can be used as a diagnostic tool. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  7. Room Temperature Optical Constants and Band Gap Evolution of Phase Pure M1-VO2 Thin Films Deposited at Different Oxygen Partial Pressures by Reactive Magnetron Sputtering

    Directory of Open Access Journals (Sweden)

    Meng Jiang

    2014-01-01

    Full Text Available Spectroscopic ellipsometry study was employed for phase pure VO2(M1 thin films grown at different oxygen partial pressures by reactive magnetron sputtering. The optical constants of the VO2(M1 thin films have been determined in a photon energy range between 0.73 and 5.05 eV. The near-infrared extinction coefficient and optical conductivity of VO2(M1 thin films rapidly increase with decreasing O2-Ar ratios. Moreover, two electronic transitions can be uniquely assigned. The energy gaps correlated with absorption edge (E1 at varied O2-Ar ratios are almost the same (~2.0 eV; consequently, the absorption edge is not significantly changed. However, the optical band gap corresponding to semiconductor-to-metal phase transition (E2 decreases from 0.53 to 0.18 eV with decreasing O2-Ar ratios.

  8. Oxygen source-oriented control of atmospheric pressure chemical vapor deposition of VO2 for capacitive applications

    Directory of Open Access Journals (Sweden)

    Dimitra Vernardou

    2016-06-01

    Full Text Available Vanadium dioxides of different crystalline orientation planes have successfully been fabricated by chemical vapor deposition at atmospheric pressure using propanol, ethanol and O2 gas as oxygen sources. The thick a-axis textured monoclinic vanadium dioxide obtained through propanol presented the best electrochemical response in terms of the highest specific discharge capacity of 459 mAh g-1 with a capacitance retention of 97 % after 1000 scans under constant specific current of 2 A g-1. Finally, the electrochemical impedance spectroscopy indicated that the charge transfer of Li+ through the vanadium dioxide / electrolyte interface was easier for this sample enhancing significantly its capacitance performance.

  9. Time limit and VO2 slow component at intensities corresponding to VO2max in swimmers.

    Science.gov (United States)

    Fernandes, R J; Cardoso, C S; Soares, S M; Ascensão, A; Colaço, P J; Vilas-Boas, J P

    2003-11-01

    The purpose of this study was to measure, in swimming pool conditions and with high level swimmers, the time to exhaustion at the minimum velocity that elicits maximal oxygen consumption (TLim at vVO(2)max), and the corresponding VO(2) slow component (O(2)SC). The vVO(2)max was determined through an intermittent incremental test (n = 15). Forty-eight hours later, TLim was assessed using an all-out swim at vVO(2)max until exhaustion. VO(2) was measured through direct oximetry and the swimming velocity was controlled using a visual light-pacer. Blood lactate concentrations and heart rate values were also measured. Mean VO(2)max for the incremental test was 5.09 +/- 0.53 l/min and the corresponding vVO(2)max was 1.46 +/- 0.06 m/s. Mean TLim value was 260.20 +/- 60.73 s and it was inversely correlated with the velocity of anaerobic threshold (r = -0.54, p energy cost of the respiratory muscles (r = 0.51), for p swimming pool, in high level swimmers performing at vVO(2)max, and that higher TLim seems to correspond to higher expected O(2)SC amplitude. These findings seem to bring new data with application in middle distance swimming.

  10. Ab Initio Metadynamics Study of the VO2+/VO2+ Redox Reaction Mechanism at the Graphite Edge/Water Interface.

    Science.gov (United States)

    Jiang, Zhen; Klyukin, Konstantin; Alexandrov, Vitaly

    2018-06-08

    Redox flow batteries (RFBs) are promising electrochemical energy storage systems, for which development is impeded by a poor understanding of redox reactions occurring at electrode/electrolyte interfaces. Even for the conventional all-vanadium RFB chemistry employing V 2+ /V 3+ and VO 2 + /VO 2+ couples, there is still no consensus about the reaction mechanism, electrode active sites, and rate-determining step. Herein, we perform Car-Parrinello molecular dynamics-based metadynamics simulations to unravel the mechanism of the VO 2 + /VO 2+ redox reaction in water at the oxygen-functionalized graphite (112̅0) edge surface serving as a representative carbon-based electrode. Our results suggest that during the battery discharge aqueous VO 2 + /VO 2+ species adsorb at the surface C-O groups as inner-sphere complexes, exhibiting faster adsorption/desorption kinetics than V 2+ /V 3+ , at least at low vanadium concentrations considered in our study. We find that this is because (i) VO 2 + /VO 2+ conversion does not involve the slow transfer of an oxygen atom, (ii) protonation of VO 2 + is spontaneous and coupled to interfacial electron transfer in acidic conditions to enable VO 2+ formation, and (iii) V 3+ found to be strongly bound to oxygen groups of the graphite surface features unfavorable desorption kinetics. In contrast, the reverse process taking place upon charging is expected to be more sluggish for the VO 2 + /VO 2+ redox couple because of both unfavorable deprotonation of the VO 2+ water ligands and adsorption/desorption kinetics.

  11. Effects of daily activity recorded by pedometer on peak oxygen consumption (VO2peak), ventilatory threshold and leg extension power in 30- to 69-year-old Japanese without exercise habit.

    Science.gov (United States)

    Zhang, Jian-Guo; Ohta, Toshiki; Ishikawa-Takata, Kazuko; Tabata, Izumi; Miyashita, Mitsumasa

    2003-09-01

    The relationships among walk steps, exercise habits and peak oxygen consumption (VO2peak), ventilatory threshold (VT) and leg extension power (LEP) were examined in 709 apparently healthy Japanese subjects (male 372, female 337) aged 30-69 years. Walk steps were evaluated using a pedometer. VO2peak and VT were assessed by a cycle ergometer test, while LEP was measured with an isokinetic leg extension system (Combi, Anaero Press 3500, Japan). Subjects who participated in exercise three times or more a week demonstrated significantly greater VO2peak and VT when compared with subjects without exercise habits. When a separate analysis was conducted on subjects who exercised fewer than three times per week, we found that the subgroup with the highest number of walk steps showed significantly greater VT in all male subjects and female subjects aged 30-49 years, but a significantly greater VO2peak only in females aged 30-49 years, when compared to the subgroup with the fewest walk steps. These results suggest that although some people exercise less than three times a week, if they are quite active in daily life, such activities might also confer benefits upon their fitness.

  12. New Methods for Processing and Quantifying VO2 Kinetics to Steady State: VO2 Onset Kinetics

    Directory of Open Access Journals (Sweden)

    Craig R. McNulty

    2017-09-01

    Full Text Available Current methods of oxygen uptake (VO2 kinetics data handling may be too simplistic for the complex physiology involved in the underlying physiological processes. Therefore, the aim of this study was to quantify the VO2 kinetics to steady state across the full range of sub-ventilatory threshold work rates, with a particular focus on the VO2 onset kinetics. Ten healthy, moderately trained males participated in five bouts of cycling. Each bout involved 10 min at a percentage of the subject's ventilation threshold (30, 45, 60, 75, 90% from unloaded cycling. The VO2 kinetics was quantified using the conventional mono-exponential time constant (tau, τ, as well as the new methods for VO2 onset kinetics. Compared to linear modeling, non-linear modeling caused a deterioration of goodness of fit (main effect, p < 0.001 across all exercise intensities. Remainder kinetics were also improved using a modified application of the mono-exponential model (main effect, p < 0.001. Interestingly, the slope from the linear regression of the onset kinetics data is similar across all subjects and absolute exercise intensities, and thereby independent of subject fitness and τ. This could indicate that there are no functional limitations between subjects during this onset phase, with limitations occurring for the latter transition to steady state. Finally, the continuing use of mono-exponential modeling could mask important underlying physiology of more instantaneous VO2 responses to steady state. Consequently, further research should be conducted on this new approach to VO2 onset kinetics.

  13. Improving the electrocatalytic performance of carbon nanotubes for VO"2"+/VO_2"+ redox reaction by KOH activation

    International Nuclear Information System (INIS)

    Dai, Lei; Jiang, Yingqiao; Meng, Wei; Zhou, Huizhu; Wang, Ling; He, Zhangxing

    2017-01-01

    Highlights: • KOH-activated carbon nanotubes (CNTs) was investigated as superior catalyst for VO"2"+/VO_2"+ redox reaction for vanadium redox flow battery (VRFB) for the first time. • KOH activation for CNTs can result in the chemical etching of surface and improved wettability, accelerating the mass transfer of vanadium ions. • KOH activation can introduce many oxygen-containing groups as active sites on the surface of CNTs. • KOH-activated CNTs as positive catalyst could increase the comprehensive energy storage performance of VRFB. - Abstract: In this paper, carbon nanotubes (CNTs) was activated by KOH treatment at high temperature and investigated as catalyst for VO"2"+/VO_2"+ redox reaction for vanadium redox flow battery (VRFB). X-ray photoelectron spectroscopy results suggest that the oxygen-containing groups can be introduced on CNTs by KOH activation. The mass transfer of vanadium ions can be accelerated by chemical etching by KOH activation and improved wettability due to the introduction of hydrophilic groups. The electrochemical properties of VO"2"+/VO_2"+ redox reaction can be enhanced by introduced oxygen-containing groups as active sites. The sample treated at 900 °C with KOH/CNTs mass ratio of 3:1 (CNTs-3) exhibits the highest electrocatalytic activity for VO"2"+/VO_2"+ redox reaction. The cell using CNTs-3 as positive catalyst demonstrates the smallest electrochemical polarization, the highest capacity and efficiency among the samples. Using KOH-activated CNTs-3 can increase the average energy efficiency of the cell by 4.4%. This work suggests that KOH-activated CNTs is a low-cost, efficient and promising catalyst for VO"2"+/VO_2"+ redox reaction for VRFB system.

  14. Feed intake and oxygen consumption in fish

    NARCIS (Netherlands)

    Subramanian, S.

    2013-01-01

    In fish, the voluntary feed intake is influenced by dietary, environmental and/or physiological factors. It is well known that under hypoxia the concentration of oxygen in the water (DO) determines the feed intake of fish. However at non-limiting water DO levels (normoxia), several other

  15. VO2(B conversion to VO2(A and VO2(M and their oxidation resistance and optical switching properties

    Directory of Open Access Journals (Sweden)

    Zhang Yifu

    2016-03-01

    Full Text Available Vanadium dioxide VO2 has been paid in recent years increasing attention because of its various applications, however, its oxidation resistance properties in air atmosphere have rarely been reported. Herein, VO2(B nanobelts were transformed into VO2(A and VO2(M nanobelts by hydrothermal route and calcination treatment, respectively. Then, we comparatively studied the oxidation resistance properties of VO2(B, VO2(A and VO2(M nanobelts in air atmosphere by thermo-gravimetric analysis and differential thermal analysis (TGA/DTA. It was found that the nanobelts had good thermal stability and oxidation resistance below 341 °C, 408 °C and 465 °C in air, respectively, indicating that they were stable in air at room temperature. The fierce oxidation of the nanobelts occurred at 426, 507 and 645 °C, respectively. The results showed that the VO2(M nanobelts had the best thermal stability and oxidation resistance among the others. Furthermore, the phase transition temperatures and optical switching properties of VO2(A and VO2(M were studied by differential scanning calorimetry (DSC and variable temperature infrared spectra. It was found that the VO2(A and VO2(M nanobelts had outstanding thermochromic character and optical switching properties.

  16. Selective formation of VO2(A) or VO2(R) polymorph by controlling the hydrothermal pressure

    International Nuclear Information System (INIS)

    Ji Shidong; Zhang Feng; Jin Ping

    2011-01-01

    Missing VO 2 (A) usually occurs during the preparation of VO 2 polymorphs. This leads to an ambiguous understanding of the transformation between VO 2 polymorphs. The calculation of the ground state energies for different VO 2 polymorphs indicated that there is only a small energy gap between VO 2 (A) and VO 2 (R), which destined that the transformation from VO 2 (A) to VO 2 (R) should be pressure sensitive. This hypothesis was verified during the synthesizing of VO 2 polymorphs by reducing V 2 O 5 with oxalic acid through hydrothermal treatment process. Selective formation of pure phase VO 2 (A) or VO 2 (R) was achieved by controlling the hydrothermal pressure through varying the filling ratio at 270 deg. C. It was found that a filling ratio over 0.5 favors the formation of pure VO 2 (R) while a reduced filling ratio to 0.4 or lower results in the formation of VO 2 (A). Based on our experiments, VO 2 (B) nanobelts were always first formed and then it transformed to VO 2 (A) by assembling process at increased temperature or extended reaction time. Under further higher pressure, the VO 2 (A) transformed spontaneously to VO 2 (R) initialized from the volume shrinkage due to the formation of denser VO 2 (R). - Graphical abstract: Selective formation of VO 2 (A) or VO 2 (R) could be achieved by controlling the system pressure through varying the filling ratio during hydrothermal treatment. Highlights: → Selective formation of VO 2 polymorphs by controlling hydrothermal pressure. → Ground state energy characteristics were revealed for the first time. → Phase transformation mechanism was clearly elucidated.

  17. Time limit and time at VO2max' during a continuous and an intermittent run.

    Science.gov (United States)

    Demarie, S; Koralsztein, J P; Billat, V

    2000-06-01

    The purpose of this study was to verify, by track field tests, whether sub-elite runners (n=15) could (i) reach their VO2max while running at v50%delta, i.e. midway between the speed associated with lactate threshold (vLAT) and that associated with maximal aerobic power (vVO2max), and (ii) if an intermittent exercise provokes a maximal and/or supra maximal oxygen consumption longer than a continuous one. Within three days, subjects underwent a multistage incremental test during which their vVO2max and vLAT were determined; they then performed two additional testing sessions, where continuous and intermittent running exercises at v50%delta were performed up to exhaustion. Subject's gas exchange and heart rate were continuously recorded by means of a telemetric apparatus. Blood samples were taken from fingertip and analysed for blood lactate concentration. In the continuous and the intermittent tests peak VO2 exceeded VO2max values, as determined during the incremental test. However in the intermittent exercise, peak VO2, time to exhaustion and time at VO2max reached significantly higher values, while blood lactate accumulation showed significantly lower values than in the continuous one. The v50%delta is sufficient to stimulate VO2max in both intermittent and continuous running. The intermittent exercise results better than the continuous one in increasing maximal aerobic power, allowing longer time at VO2max and obtaining higher peak VO2 with lower lactate accumulation.

  18. Multiple variables explain the variability in the decrement in VO2max during acute hypobaric hypoxia.

    Science.gov (United States)

    Robergs, R A; Quintana, R; Parker, D L; Frankel, C C

    1998-06-01

    We used multiple regression analyses to determine the relationships between the decrement in sea level (SL, 760 Torr) VO2max during hypobaric hypoxia (HH) and variables that could alter or be related to the decrement in VO2max. HH conditions consisted of 682 Torr, 632 Torr, and 566 Torr, and the measured independent variables were SL-VO2max, SL lactate threshold (SL-LT), the change in hemoglobin saturation at VO2max between 760 and 566 Torr (delta SaO2max), lean body mass (LBM), and gender. Male (N = 14) and female (N = 14) subjects of varied fitness, training status, and residential altitude (1,640-2,460 m) completed cycle ergometry tests of VO2max at each HH condition under randomized and single-blinded conditions. VO2max decreased significantly from 760 Torr after 682 Torr (approximately 915 m) (3.5 +/- 0.9 to 3.4 +/- 0.8 L.min-1, P = 0.0003). Across all HH conditions, the slope of the relative decrement in VO2max (%VO2max) during HH was -9.2%/100 mm Hg (-8.1%/1000 m) with an initial decrease from 100% estimated to occur below 705 Torr (610 m). Step-wise multiple regression revealed that SL-VO2max, SL-LT, delta SaO2max, LBM, and gender each significantly combined to account for 89.03% of the variance in the decrement in VO2max (760-566 Torr) (P decrement in VO2max during HH. The unique variance explanation afforded by SL-LT, LBM, and gender suggests that issues pertaining to oxygen diffusion within skeletal muscle may add to the explanation of between subjects variability in the decrement in VO2max during HH.

  19. MAXIMAL OXIGEN UPTAKE (VO2 MAX AS THE INDICATOR OF PHYSICAL WORKING CAPACITY IN SPORTSMEN

    Directory of Open Access Journals (Sweden)

    Zvezdana Rajkovaca

    2005-12-01

    Full Text Available The term “aerobic capacity” represents the sum of aerobic metabolic processes in human organism. It is the basis of the physical working capacity. Value of the maximal oxygen uptake (VO2max is the best indicator for the aerobic capacity evaluation.The purpose of this study was to check the possibility of using VO2max as the indicator of aerobic capacity in sportsmen and to check differences in VO2max values in regard to non-sportsmen.The goals were: 1.Analyses of the VO2max values in sportsmen of various sports 2. Comparison of values of sportsmen with the values of non-sportsmen.This study included 67 sportsmen (rowers, football players and judoists and 28 nonsportsmen. VO2max was measured by using a direct method.The results obtained show statistically higher VO2max values in rowers (4,52 L/min - 55,8 mL/kg/min in regard to football players (4,2 L/min – 53,6 mL/kg/min, judoists (3,58 L/min - 47,2 mL/ kg/min and non-sportsmen (3,28 L/min – 42,3 mL/kg/min. Successful rowing requires high anaerobic capacity and, therefore, high VO2max.These results show higher values of VO2max in sportsmen in regard to non-sportsmen, which is the result of training only.

  20. Human mitochondrial haplogroup H: the highest VO2max consumer--is it a paradox?

    Science.gov (United States)

    Martínez-Redondo, Diana; Marcuello, Ana; Casajús, José A; Ara, Ignacio; Dahmani, Yahya; Montoya, Julio; Ruiz-Pesini, Eduardo; López-Pérez, Manuel J; Díez-Sánchez, Carmen

    2010-03-01

    Mitochondrial background has been demonstrated to influence maximal oxygen uptake (VO(2max), in mLkg(-1)min(-1)), but this genetic influence can be compensated for by regular exercise. A positive correlation among electron transport chain (ETC) coupling, ATP and reactive oxygen species (ROS) production has been established, and mitochondrial variants have been reported to show differences in their ETC performance. In this study, we examined in detail the VO(2max) differences found among mitochondrial haplogroups. We recruited 81 healthy male Spanish Caucasian individuals and determined their mitochondrial haplogroup. Their VO(2max) was determined using incremental cycling exercise (ICE). VO(2max) was lower in J than in non-J haplogroup individuals (P=0.04). The H haplogroup was responsible for this difference (VO(2max); J vs. H; P=0.008) and this group also had significantly higher mitochondrial oxidative damage (mtOD) than the J haplogroup (P=0.04). In agreement with these results, VO(2max) and mtOD were positively correlated (P=0.01). Given that ROS production is the major contributor to mtOD and consumes four times more oxygen per electron than the ETC, our results strongly suggest that ROS production is responsible for the higher VO(2max) found in the H variant. These findings not only contribute to a better understanding of the mechanisms underneath VO(2max), but also help to explain some reported associations between mitochondrial haplogroups and mtOD with longevity, sperm motility, premature aging and susceptibility to different pathologies.

  1. Electrochemical catalytic activity of tungsten trioxide- modified graphite felt toward VO2+/VO2+ redox reaction

    International Nuclear Information System (INIS)

    Shen, Yang; Xu, Hongfeng; Xu, Pengcheng; Wu, Xiaoxin; Dong, Yiming; Lu, Lu

    2014-01-01

    A novel graphite felt electrode modified with tungsten trioxide (WO 3 ) was developed to improve the electrochemical performance of graphite felt toward the VO 2 + /VO 2+ redox pair. WO 3 was prepared using a hydrothermal method, and the morphology of WO 3 structures was investigated by scanning electron microscopy (SEM) and X-ray diffraction (XRD). The electrochemical property of WO 3 -modified graphite felt toward VO 2 + /VO 2+ was carefully characterized using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements. The hydrogen-vanadium redox flow battery (H-VRFB) test indicates that single cells using 1.1 mg cm −2 WO 3 -modified graphite felt exhibited excellent performance at 70 mA cm −2 , and the corresponding coulombic, voltage, and energy efficiencies were 99.1%, 88.66% and 87.86%, respectively

  2. Increases in .VO2max with "live high-train low" altitude training: role of ventilatory acclimatization.

    Science.gov (United States)

    Wilhite, Daniel P; Mickleborough, Timothy D; Laymon, Abigail S; Chapman, Robert F

    2013-02-01

    The purpose of this study was to estimate the percentage of the increase in whole body maximal oxygen consumption (.VO(2max)) that is accounted for by increased respiratory muscle oxygen uptake after altitude training. Six elite male distance runners (.VO(2max) = 70.6 ± 4.5 ml kg(-1) min(-1)) and one elite female distance runner (.VO(2max)) = 64.7 ml kg(-1) min(-1)) completed a 28-day "live high-train low" training intervention (living elevation, 2,150 m). Before and after altitude training, subjects ran at three submaximal speeds, and during a separate session, performed a graded exercise test to exhaustion. A regression equation derived from published data was used to estimate respiratory muscle .VO(2) (.VO(2RM)) using our ventilation (.VE) values. .VO(2RM) was also estimated retrospectively from a larger group of distance runners (n = 22). .VO(2max) significantly (p altitude (196 ± 59 ml min(-1)), while (.VE) at .VO(2max) also significantly (p altitude (201 ± 36 ml min(-1)), along with a 10.8 ± 2.1 l min(-1) increase in (.VE), thus requiring an estimated 27 % of Δ .VO(2max) Our data suggest that a substantial portion of the improvement in .VO(2max) with chronic altitude training goes to fuel the respiratory muscles as opposed to the musculature which directly contributes to locomotion. Consequently, the time-course of decay in ventilatory acclimatization following return to sea-level may have an impact on competitive performance.

  3. Slow VO2 off-kinetics in skeletal muscle is associated with fast PCr off-kinetics--and inversely.

    Science.gov (United States)

    Korzeniewski, Bernard; Zoladz, Jerzy A

    2013-09-01

    The computer model of the bioenergetic system in skeletal muscle, developed previously, was used to study the effect of the characteristic decay time of the parallel activation of oxidative phosphorylation [τ(OFF)] during muscle recovery on the muscle oxygen consumption rate (Vo2) and phosphocreatine (PCr) work-to-rest transition (off)-kinetics and on the relationship between the Vo2 and PCr rest-to-work transition (on)- and off-kinetics in moderate and heavy exercise. An increase in τ(OFF) slows down the initial phase of the muscle Vo2 off-kinetics and accelerates the PCr off-kinetics. As a result, the relationship between the initial phase of the Vo2 off-kinetics (lasting approximately 3-60 s in computer simulations) and the PCr off-kinetics is inverse: the slower the former, the faster the latter. A faster initial phase of the Vo2 off-kinetics is associated with a slower late phase of the Vo2 off-kinetics, and as a result, the integral of Vo2 above baseline during recovery, representing the oxygen debt, is identical in all cases [values of τ(OFF)] for a given PCr decrease. Depending on τ(OFF), the muscle Vo2 on-kinetics was either equally fast or slower than the Vo2 off-kinetics in moderate exercise and always slower in heavy exercise. PCr on-kinetics was always faster than PCr off-kinetics. This study clearly demonstrates that τ(OFF) has a pronounced impact on the mutual relations between the muscle Vo2 and PCr on- and off-kinetics.

  4. Observation of reduced phase transition temperature in N-doped thermochromic film of monoclinic VO_2

    International Nuclear Information System (INIS)

    Wan, Meinan; Xiong, Mo; Li, Neng; Liu, Baoshun; Wang, Shuo; Ching, Wai-Yim; Zhao, Xiujian

    2017-01-01

    Highlights: • N-doped VO_2(M1) thin films have been synthesized by annealing in NH_3 atmosphere. • The phase purity, microstructure and optical property of VO_2 thin film can be regulated by NH_3 concentration. • First-principles calculations have been carried out to study the mechanism of N-doping on energy band structures of VO_2(M1). • The energy band gaps of VO_2(M1) are tuned by substitution N-doping or interstitial N-doping. - Abstract: Research on monoclinic (M1) phase of VO_2 has attracted a great of interest for smart coating applications due to its exceptional thermochromic property. Herein, we report the results using a novel approach to synthesize N-doped VO_2(M1) thin films with high purity by heat treatment in NH_3 atmosphere. The N dopant in the film can be regulated by varying NH_3 concentration during the annealing process. We find that the N atoms are located at the interstitial sites or substitute oxygen atoms, and the V-N bonds in the VO_2 thin films increase with NH_3 concentration. The metal to insulator transition (MIT) temperature (τ_c_,_h) of the VO_2 thin film is effectively reduced from 80.0 to 62.9 °C, while the solar modulation efficiency (ΔT_s_o_l) and the modulation efficiency at 2000 nm (ΔT_2_0_0_0_n_m) are 7.36% and 55.6% respectively. The band gap of N-doped VO_2 thin films related to MIT (E_g_1) is estimated to be as low as 0.18–0.25 eV whereas the band gap associated with the visible transparency (E_g_2) is about 1.50–1.58 eV. Based on the highly accurate first-principles calculations, the E_g_1 of VO_2 (M1) is reduced after substituted or interstitial N-doping, while the E_g_2 alters with the mode of N-doping, which is excellent agreement with experimental measurement.

  5. Electrocatalytic activity of cobalt phosphide-modified graphite felt toward VO2+/VO2+ redox reaction

    Science.gov (United States)

    Ge, Zhijun; Wang, Ling; He, Zhangxing; Li, Yuehua; Jiang, Yingqiao; Meng, Wei; Dai, Lei

    2018-04-01

    A novel strategy for improving the electro-catalytic properties of graphite felt (GF) electrode in vanadium redox flow battery (VRFB) is designed by depositing cobalt phosphide (CoP) onto GF surface. The CoP powder is synthesized by direct carbonization of Co-based zeolitic imidazolate framework (ZIF-67) followed by phosphidation. Cyclic voltammetry results confirm that the CoP-modified graphite felt (GF-CoP) electrode has excellent reversibility and electro-catalytic activity to the VO2+/VO2+ cathodic reaction compared with the pristine GF electrode. The cell using GF-CoP electrode shows apparently higher discharge capacity over that based on GF electrode. The cell using GF-CoP electrode has the capacity of 67.2 mA h at 100 mA cm-2, 32.7 mA h larger than that using GF electrode. Compared with cell using GF electrode, the voltage efficiency of the cell based on GF-CoP electrode increases by 5.9% and energy efficiency by 5.4% at a current density of 100 mA cm-2. The cell using GF-CoP electrode can reach 94.31% capacity retention after 50 cycles at a current density of 30 mA cm-2. The results show that the CoP can effectively promote the VO2+/VO2+ redox reaction, implying that metal phosphides are a new kind of potential catalytic materials for VRFB.

  6. Low-level laser therapy improves the VO2 kinetics in competitive cyclists.

    Science.gov (United States)

    Lanferdini, Fábio J; Krüger, Renata L; Baroni, Bruno M; Lazzari, Caetano; Figueiredo, Pedro; Reischak-Oliveira, Alvaro; Vaz, Marco A

    2018-04-01

    Some evidence supports that low-level laser therapy (LLLT) reduces neuromuscular fatigue, so incrementing sports performance. A previous randomized controlled trial of our group showed increased exercise tolerance in male competitive cyclists treated with three different LLLT doses (3, 6, and 9 J/diode; or 135, 270, and 405 J/thigh) before time-to-exhaustion cycling tests. Now, the present study was designed to evaluate the effects of these LLLT doses on the VO 2 kinetics of athletes during cycling tests. Twenty male competitive cyclists (29 years) participated in a crossover, randomized, double-blind, and placebo-controlled trial. On the first day, the participants performed an incremental cycling test to exhaustion to determine maximal oxygen uptake (VO 2MAX ) and maximal power output (PO MAX ), as well as a familiarization with the time-to-exhaustion test. In the following days (2 to 5), all participants performed time-to-exhaustion tests at PO MAX . Before the exhaustion test, different doses of LLLT (3, 6, and 9 J/diode; or 135, 270, and 405 J/thigh, respectively) or placebo were applied bilaterally to the quadriceps muscle. All exhaustion tests were monitored online by an open-circuit spirometry system in order to analyze the VO 2 amplitude, VO 2 delay time, time constant (tau), and O 2 deficit. Tau and O 2 deficit were decreased with LLLT applications compared to the placebo condition (p  0.05) were found between the experimental conditions for VO 2 amplitude and VO 2 delay time. In conclusion, LLLT decreases tau and O 2 deficit during time-to-exhaustion tests in competitive cyclists, and these changes in VO 2 kinetics response can be one of the possible mechanisms to explain the ergogenic effect induced by LLLT.

  7. Relationship between running kinematic changes and time limit at vVO2max

    Directory of Open Access Journals (Sweden)

    Leonardo De Lucca

    2012-06-01

    Exhaustive running at maximal oxygen uptake velocity (vVO2max can alter running kinematic parameters and increase energy cost along the time. The aims of the present study were to compare characteristics of ankle and knee kinematics during running at vVO2max and to verify the relationship between changes in kinematic variables and time limit (Tlim. Eleven male volunteers, recreational players of team sports, performed an incremental running test until volitional exhaustion to determine vVO2max and a constant velocity test at vVO2max. Subjects were filmed continuously from the left sagittal plane at 210 Hz for further kinematic analysis. The maximal plantar flexion during swing (p<0.01 was the only variable that increased significantly from beginning to end of the run. Increase in ankle angle at contact was the only variable related to Tlim (r=0.64; p=0.035 and explained 34% of the performance in the test. These findings suggest that the individuals under study maintained a stable running style at vVO2max and that increase in plantar flexion explained the performance in this test when it was applied in non-runners.

  8. Influence of nitrate supplementation on VO(2) kinetics and endurance of elite cyclists

    DEFF Research Database (Denmark)

    Christensen, Peter Møller; Nyberg, Michael Permin; Bangsbo, Jens

    2013-01-01

    The present study examined if an elevated nitrate intake would improve VO(2) kinetics, endurance, and repeated sprint capacity in elite endurance athletes. Ten highly trained cyclists (72¿±¿4¿mL O(2) /kg/min, mean¿±¿standard deviation) underwent testing for VO(2) kinetics (3¿×¿6¿min at 298¿±¿28¿W...... juice. Plasma NOx (nitrate¿+¿nitrite) levels were higher (P¿......The present study examined if an elevated nitrate intake would improve VO(2) kinetics, endurance, and repeated sprint capacity in elite endurance athletes. Ten highly trained cyclists (72¿±¿4¿mL O(2) /kg/min, mean¿±¿standard deviation) underwent testing for VO(2) kinetics (3¿×¿6¿min at 298¿±¿28¿W......), endurance (120¿min preload followed by a 400-kcal time trial), and repeated sprint capacity (6¿×¿20¿s sprints, recovery 100¿s) during two 6-day periods in randomized order with a daily ingestion of either 0.5¿L beetroot (BR) juice to increase nitrate levels or a 0.5¿L placebo (PLA) drink with blackcurrant...

  9. Insulator-metal transition in substrate-independent VO2 thin film for phase-change devices.

    Science.gov (United States)

    Taha, Mohammad; Walia, Sumeet; Ahmed, Taimur; Headland, Daniel; Withayachumnankul, Withawat; Sriram, Sharath; Bhaskaran, Madhu

    2017-12-20

    Vanadium has 11 oxide phases, with the binary VO 2 presenting stimuli-dependent phase transitions that manifest as switchable electronic and optical features. An elevated temperature induces an insulator-to-metal transition (IMT) as the crystal reorients from a monoclinic state (insulator) to a tetragonal arrangement (metallic). This transition is accompanied by a simultaneous change in optical properties making VO 2 a versatile optoelectronic material. However, its deployment in scalable devices suffers because of the requirement of specialised substrates to retain the functionality of the material. Sensitivity to oxygen concentration and larger-scale VO 2 synthesis have also been standing issues in VO 2 fabrication. Here, we address these major challenges in harnessing the functionality in VO 2 by demonstrating an approach that enables crystalline, switchable VO 2 on any substrate. Glass, silicon, and quartz are used as model platforms to show the effectiveness of the process. Temperature-dependent electrical and optical characterisation is used demonstrating three to four orders of magnitude in resistive switching, >60% chromic discrimination at infrared wavelengths, and terahertz property extraction. This capability will significantly broaden the horizon of applications that have been envisioned but remained unrealised due to the lack of ability to realise VO 2 on any substrate, thereby exploiting its untapped potential.

  10. Prognostic impact of peakVO2-changes in stable CHF on chronic beta-blocker treatment.

    Science.gov (United States)

    Frankenstein, L; Nelles, M; Hallerbach, M; Dukic, D; Fluegel, A; Schellberg, D; Katus, H A; Remppis, A; Zugck, C

    2007-11-15

    Peak oxygen uptake (pVO2) is used for risk stratification in chronic heart failure (CHF), but little is known about the prognostic impact of pVO2-changes in patients on chronic beta-blocker (BBL) therapy. We therefore prospectively evaluated individual pVO2-changes at a 6-month interval in patients all receiving BBL. 194 patients with stable CHF on stable medication were included (V1) and underwent clinical evaluation and exercise testing. Testing was repeated (V2) at 5.7+/-1.5 months after V1 and patients were followed >12 months after V2. Death or hospitalisation due to cardiac reasons was the predefined EP (EPP, end-point positive; n=62; EPN, end-point negative; n=113). Initial characteristics did not differ between EPP and EPN. Multivariate cox regression analysis revealed that change of pVO2 (EPP: -0.6+/-2.6 ml/kg min; EPN: +2.5+/-3.3 ml/kg min; p<0.001) was independent to pVO2, LVEF, NTproBNP and NYHA at V2 for prediction of the combined end-point during follow-up. An increase of pVO2 by 10% was identified as an adequate cut-off value for risk stratification and ROC-analysis showed the significant incremental prognostic value of the determination of pVO2 changes in combination with pVO2. Serial measurements of pVO2 yield additional information for risk stratification in clinically homogenous CHF patients receiving BBL. This is the first study demonstrating this fact within a narrow predefined interval with all patients on BBL.

  11. HEART RATE VARIABILITY AND BODY COMPOSITION AS VO2MAX DETERMINANTS

    Directory of Open Access Journals (Sweden)

    Henry Humberto León-Ariza

    Full Text Available ABSTRACT Introduction: The maximum oxygen consumption (VO2max is the gold standard in the cardiorespiratory endurance assessment. Objective: This study aimed to develop a mathematical model that contains variables to determine the VO2max of sedentary people. Methods: Twenty participants (10 men and 10 women with a mean age of 19.8±1.77 years were included. For each participant, body composition (percentage of fat and muscle, heart rate variability (HRV at rest (supine and standing, and VO2max were evaluated through an indirect test on a cycloergometer. A multivariate linear regression model was developed from the data obtained, and the model assumptions were verified. Results: Using the data obtained, including percentage of fat (F, percentage of muscle (M, percentage of power at very low frequency (VLF, α-value of the detrended fluctuation analysis (DFAα1, heart rate (HR in the resting standing position, and age of the participants, a model was established for men, which was expressed as VO2max = 4.216 + (Age*0.153 + (F*0.110 - (M*0.053 - (VLF*0.649 - (DFAα1*2.441 - (HR*0.014, with R2 = 0.965 and standard error = 0.146 L/min. For women, the model was expressed as VO2max = 1.947 - (Age*0.047 + (F*0.024 + (M*0.054 + (VLF*1.949 - (DFAα1*0.424 - (HR*0.019, with R2 = 0.987 and standard error = 0.077 L/min. Conclusion: The obtained model demonstrated the influence exerted by body composition, the autonomic nervous system, and age in the prediction of VO2max.

  12. Estimated Prestroke Peak VO2 Is Related to Circulating IGF-1 Levels During Acute Stroke.

    Science.gov (United States)

    Mattlage, Anna E; Rippee, Michael A; Abraham, Michael G; Sandt, Janice; Billinger, Sandra A

    2017-01-01

    Background Insulin-like growth factor-1 (IGF-1) is neuroprotective after stroke and is regulated by insulin-like binding protein-3 (IGFBP-3). In healthy individuals, exercise and improved aerobic fitness (peak oxygen uptake; peak VO 2 ) increases IGF-1 in circulation. Understanding the relationship between estimated prestroke aerobic fitness and IGF-1 and IGFBP-3 after stroke may provide insight into the benefits of exercise and aerobic fitness on stroke recovery. Objective The purpose of this study was to determine the relationship of IGF-1 and IGFBP-3 to estimated prestroke peak VO 2 in individuals with acute stroke. We hypothesized that (1) estimated prestroke peak VO 2 would be related to IGF-1 and IGFBP-3 and (2) individuals with higher than median IGF-1 levels will have higher estimated prestroke peak VO 2 compared to those with lower than median levels. Methods Fifteen individuals with acute stroke had blood sampled within 72 hours of hospital admission. Prestroke peak VO 2 was estimated using a nonexercise prediction equation. IGF-1 and IGFBP-3 levels were quantified using enzyme-linked immunoassay. Results Estimated prestroke peak VO 2 was significantly related to circulating IGF-1 levels (r = .60; P = .02) but not IGFBP-3. Individuals with higher than median IGF-1 (117.9 ng/mL) had significantly better estimated aerobic fitness (32.4 ± 6.9 mL kg -1 min -1 ) than those with lower than median IGF-1 (20.7 ± 7.8 mL kg -1 min -1 ; P = .03). Conclusions Improving aerobic fitness prior to stroke may be beneficial by increasing baseline IGF-1 levels. These results set the groundwork for future clinical trials to determine whether high IGF-1 and aerobic fitness are beneficial to stroke recovery by providing neuroprotection and improving function. © The Author(s) 2016.

  13. Estimated VO2max and its corresponding velocity predict performance of amateur runners

    Directory of Open Access Journals (Sweden)

    Bruno Ribeiro Ramalho Oliveira

    2012-03-01

    Full Text Available In recent years, there has been a substantial increase in the number of runners, with a proportional increase in their involvement in amateur street competition. Identification of the determinants of performance in this population appears necessary for optimization of time devoted to training. The objective of this study was to ascertain the association between estimated maximal oxygen uptake (VO2max, critical velocity (CV and VO2max velocity (VVO2max and athletic performance in the 3.6 km (uphill and 10 and 21.1 km (flatland events. Twelve amateur runners (nine male, mean age 36 ± 5 years underwent five tests: 1 and 5 km race on level ground, 3.6 km race with slope (≈8%, and indirect VO2max measurement. CV was determined from the linear relationship between distance and run time on the first two tests. The subjects then took part in two official 10 km and 21.1 km (half marathon races. VVO2max was calculated from the VO2max through a metabolic equation. VO2max showed the best association with running performance in the 10 and 21.1 km events. For the uphill race, VVO2max showed a better association. Overall, the variable with the highest average association was VO2max (0.91±0.07, followed by VVO2max (0.90±0.04 and VC (0.87±0.06. This study showed strong associations between physiological variables established by low-cost, user-friendly indirect methods and running performance in the 10 and 21.1 km (flatland and 3.6 km (uphill running events.

  14. Why is VO2 max after altitude acclimatization still reduced despite normalization of arterial O2 content?

    DEFF Research Database (Denmark)

    Calbet, J A L; Boushel, Robert Christopher; Radegran, G

    2003-01-01

    Acute hypoxia (AH) reduces maximal O2 consumption (VO2 max), but after acclimatization, and despite increases in both hemoglobin concentration and arterial O2 saturation that can normalize arterial O2 concentration ([O2]), VO2 max remains low. To determine why, seven lowlanders were studied at VO2......% of the cardiac output perfused the legs, in CH the legs received only 67%. Pulmonary VO2 max (4.1 +/- 0.3 l/min at SL) fell to 2.2 +/- 0.1 l/min in AH (P normalization...... of arterial [O2] is explained by two circulatory effects of altitude: 1) failure of cardiac output to normalize and 2) preferential redistribution of cardiac output to nonexercising tissues. Oxygen transport from blood to muscle mitochondria, on the other hand, appears unaffected by CH....

  15. Luminous transmittance and phase transition temperature of VO 2 ...

    African Journals Online (AJOL)

    The phase transition temperature (τc) of the films was obtained from both the transmittance and sheet resistance against temperature curves. A change in sheet resistance of 2 to 3 orders of magnitude was observed for both undoped and Ce-doped VO2 films. Comparison between undoped and doped VO2 films revealed ...

  16. A acurácia da determinação do VO2max e do limiar anaeróbio La exactitud en la determinacion del VO2máx y del umbral anaerobico Accuracy of VO2max and anaerobic threshold determination

    Directory of Open Access Journals (Sweden)

    Paulo Cesar N Granja Filho

    2005-06-01

    Full Text Available São raros estudos que tratam da acurácia de parâmetros de trocas gasosas durante o esforço, com a população brasileira. OBJETIVO: Determinar a confiabilidade do consumo máximo de oxigênio (VO2max e do limiar anaeróbio (LAn, assim como, a objetividade do segundo (LAn em adultos jovens saudáveis. MÉTODOS: Foram aplicados dois testes de esforço máximo, a partir dos quais dois observadores independentes determinaram o LAn através do método de inspeção visual. Os dados foram tratados por meio da análise de regressão, coeficiente de correlação intraclasse (CCI, ANOVA com dois fatores com teste post hoc de Tukey e teste t pareado para alfa Son raros los estudios que tratan de la exactitud de los parámetros de cambios gaseosos durante el esfuerzo con la población brasileña. OBJETIVO: Determinar la confiabilidad del consumo máximo de oxigeno (VO2max y del umbral anaeróbico (LAn, así como la objetividad del segundo, (LAn en adultos jovenes saludables. MÉTODOS: Fueron aplicados dos tests de esfuerzo máximo, a partir de los cuales dos observadores independientes determinaron el LAn a través del método de inspección visual. Los datos fueron tratados por medio del análisis de regresión, coeficiente de relación intraclase (CCI, ANOVA com dos factores con test post hoc de Tukey y el test t apareado para alfa Studies on the accuracy of the gas exchange and ventilation parameters during exertion involving the Brazilian population are scarce in literature. OBEJCTIVE: To determine the reliability of the maximal oxygen intake (VO2max and anaerobic threshold (AnT, as well as the objectivity of the AnT determination in Brazilian healthy youth adults. METHODS: Two tests of maximal exertion were applied. Two independent observers applied the visual inspection method for the AnT determination. The data were compared by means of the regression analysis, intraclass correlation coefficient (ICC, two-way ANOVA and the paired t-test for an

  17. Is Recreational Soccer Effective for Improving VO2max A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Milanović, Zoran; Pantelić, Saša; Čović, Nedim; Sporiš, Goran; Krustrup, Peter

    2015-09-01

    Soccer is the most popular sport worldwide, with a long history and currently more than 500 million active participants, of whom 300 million are registered football club members. On the basis of scientific findings showing positive fitness and health effects of recreational soccer, FIFA (Fédération Internationale de Football Association) introduced the slogan "Playing football for 45 min twice a week-best prevention of non-communicable diseases" in 2010. The objective of this paper was to perform a systematic review and meta-analysis of the literature to determine the effects of recreational soccer on maximal oxygen uptake (VO2max). Six electronic databases (MEDLINE, PubMed, SPORTDiscus, Web of Science, CINAHL and Google Scholar) were searched for original research articles. A manual search was performed to cover the areas of recreational soccer, recreational physical activity, recreational small-sided games and VO2max using the following key terms, either singly or in combination: recreational small-sided games, recreational football, recreational soccer, street football, street soccer, effect, maximal oxygen uptake, peak oxygen uptake, cardiorespiratory fitness, VO2max. The inclusion criteria were divided into four sections: type of study, type of participants, type of interventions and type of outcome measures. Probabilistic magnitude-based inferences for meta-analysed effects were based on standardised thresholds for small, moderate and large changes (0.2, 0.6 and 1.2, respectively) derived from between-subject standard deviations for baseline fitness. Seventeen studies met the inclusion criteria and were included in the systematic review and meta-analysis. Mean differences showed that VO2max increased by 3.51 mL/kg/min (95 % CI 3.07-4.15) over a recreational soccer training programme in comparison with other training models. The meta-analysed effects of recreational soccer on VO2max compared with the controls of no exercise, continuous running and strength

  18. PENGEMBANGAN PERSAMAAN VO2 MAX DAN EVALUASI HR MAX (STUDI AWAL PADA PEKERJA PRIA

    Directory of Open Access Journals (Sweden)

    Purnawan Adi Wicaksono

    2012-10-01

    berganda memberikan hasil persamaan sebagai berikut :VO2 Max = 3,996 - 0,046 usia. Sedangkan untuk evaluasi persamaan HR Max memberikan hasil bahwa persamaan terpilih yang memprediksi nilai HR Max pekerja industri pria Indonesia lebih baik adalah persamaan Tanaka et al. (2001. Penelitian memberikan hasil lain yaitu mencoba untuk mengembangkan persamaan HR Max untuk pekerja industri pria Indonesia. Dengan menggunakan regresi linier berganda memberikan hasil persamaan sebagai berikut: HR Max = 202,71 – 0,541 usia. VO2 Max dan HR Max yang dikaji dapat dijadikan sebagai referensi kriteria justifikasi kemampuan maksimum seseorang sehingga dapat dijadikan sebagai dasar perancangan sistem kerja agar beban kerja yang diterima pekerja tidak melebihi kapasitas maksimumnya. Penelitian yang mengembangkan persamaan prediksi VO2 Max dan evaluasi persamaan HR Max di Indonesia masih terbatas, sehingga dirasa perlu untuk mengembangkan persamaan prediksi VO2 Max dan evaluasi HR Max karena manfaatnya besar bagi dunia industri.. Dalam dunia pendidikan, penelitian kali ini dapat dijadikan sebagai studi awal yang dapat dikembangkan untuk penelitian – penelitian selanjutnya. Kata Kunci : VO2 max, kapasitas aerobik,kapasitas fisik maksimum, model prediksi, evaluasi HR Max   Abstract Maximum physical capacity of a person represented by the maximum oxygen consumption (VO2 Max and the maximum pulse rate (HR Max which gives a maximum of information limits a person's physical ability to do the job. The current study has the objective to find the value of VO2 Max Indonesia for male workers will be developed a prediction equation VO2 Max is approximated by a linear relationship between pulse rate (Heart Rate as that of Astrand (2003, height (Chatterjee et al, 2006 , weight (deceivingly et al, 2008, age (Magrani et al, 2009 and evaluate HR Max Which equation can be applied to approximate the value of the maximum pulse rate of Indonesian workers. Respondents in the study was 12 male industrial

  19. Cinética do consumo de oxigênio e tempo limite na vvo2max: comparação entre homens e mulheres Oxygen uptake kinetics and threshold time at the vVO2max: tomparison between men and women

    Directory of Open Access Journals (Sweden)

    Paulo Henrique Silva Marques de Azevedo

    2010-08-01

    Full Text Available Foi investigada a influência do gênero no tempo limite (Tlim e na cinética do VO2 durante corrida na velocidade associada ao VO2max (vVO2max em nove homens e nove mulheres, todos adultos, jovens e sedentários, com idades entre 20 e 30 anos. Homens e mulheres realizaram dois testes em esteira rolante, sendo um teste incremental para determinar VO2max (42,66 ± 4,50 vs. 32,92 ± 6,03mL.kg-1.min-1 e vVO2max (13.2 ± 1.5 vs. 10,3 ± 2,0km.h-1, respectivamente. Um segundo teste com carga constante na vVO2max até a exaustão. O Tlim e a cinética do VO2 foram determinados. Não houve diferença significante entre homens e mulheres para constante de tempo (τ (35,76 ± 21,03 vs. 36,5 ± 6,21s, respectivamente; P = 0,29; Tlim (308 ± 84,3 vs. 282,11 ± 57,19s, respectivamente; P = 0,68, tempo para atingir o VO2max (TAVO2max (164,48 ± 96,73 vs. 167,88 ± 28,59s, respectivamente; P = 0,29, tempo para atingir o VO2max em percentual do Tlim (%Tlim (50,24 ± 16,93 vs. 62,63 ± 16,60%, respectivamente; P = 0,19, tempo mantido no VO2max (TMVO2max (144,08 ± 42,55 vs. 114,23 ± 76,96s, respectivamente; P = 0,13. Estes resultados sugerem que a cinética do VO2 e o Tlim são similares entre homens e mulheres sedentários na vVO2max.The aim of this study was to investigate the influence of gender on Tthre and VO2 response during running exercise performed at vVO2max. Therefore, eighteen untrained individuals (9 male and 9 female with normal weight and aged between 20 - 30 years (VO2max = 42.66 ± 4.50 vs 32.92 ± 6.03 mL.kg-1.min-1 and vVO2max = 13.2 ± 1.5 vs 10.3 ± 2.0 km.h-1, for male and female, respectively were assessed. Subjects performed two exercise tests on treadmill. First one was an incremental test to determine VO2max, velocity at VO2max (vVO2max and second test was performed at steady velocity - vVO2max - until exhaustion. The threshold time (Tthre and VO2 kinetics response was determined. No significant differences were observed between men

  20. A comparison of VO2max and metabolic variables between treadmill running and treadmill skating.

    Science.gov (United States)

    Koepp, Kriston K; Janot, Jeffrey M

    2008-03-01

    The purpose of this study was to determine differences in VO2max and metabolic variables between treadmill running and treadmill skating. This study also examined VO2max responses during a continuous skating treadmill protocol and a discontinuous skating treadmill protocol. Sixteen male high school hockey players, who had a mean age of 16 +/- 1 years and were of an above-average fitness level, participated in this study. All subjects completed 4 exercise trials: a 1-hour skating treadmill familiarization trial, a treadmill running trial, and 2 randomized skating treadmill trials. Minute ventilation (VE), oxygen consumption VO2), carbon dioxide production VCO2), respiratory exchange ratio (RER), and heart rate were averaged every 15 seconds up to VO2max for each exercise test. The results showed that there was a significant difference (P skating treadmill protocol. There was also a significant difference for maximal RER between the discontinuous and continuous skating treadmill protocol and between the discontinuous skating treadmill protocol and running treadmill protocol. In conclusion, the running treadmill elicited a greater VO2max (mL.kg.min) than the skating treadmill did, but when it comes to specificity of ice skating, the skating treadmill may be ideal. Also, there was no significant difference between the discontinuous and continuous skating treadmill protocols. Therefore, a continuous protocol is possible on the skating treadmill without compromising correct skating position and physiologic responses. However, the continuous skating treadmill protocol should undergo validation before other scientists, coaches, and strength and conditioning professionals can apply it correctly.

  1. Seasonal variation of VO 2 max and the VO2-work rate relationship in elite Alpine skiers.

    Science.gov (United States)

    Gross, Micah A; Breil, Fabio A; Lehmann, Andrea D; Hoppeler, Hans; Vogt, Michael

    2009-11-01

    Alpine ski performance relates closely to both anaerobic and aerobic capacities. During their competitive season, skiers greatly reduce endurance and weight training, and on-snow training becomes predominant. To typify this shift, we compared exhaustive ramp cycling and squat (SJ) and countermovement jumping (CMJ) performance in elite males before and after their competitive season. In postseason compared with preseason: 1) maximal oxygen uptake (VO 2 max) normalized to bodyweight was higher (55.2 +/- 5.2 vs 52.7 +/- 3.6 mL x kg(-1) x min(-1), P jump height was greater in SJ (47.4 +/- 4.4 vs 44.7 +/- 4.3 cm, P skiing seemingly provides an ample cardiovascular training stimulus for skiers to maintain their aerobic capacities during the racing season. We conclude that aerobic fitness and leg explosiveness can be maintained in-season but may be compromised by heavy or excessive preseason training. In addition, ramp test V O2/W slope analysis could be useful for monitoring both positive and negative responses to training.

  2. Hydrothermal synthesis and electrochemical characterization of VO2 (B) with controlled crystal structures

    International Nuclear Information System (INIS)

    Jiang Wentao; Ni Juan; Yu Ke; Zhu Ziqiang

    2011-01-01

    Three different VO 2 (B) nanostructures, including urchin-like VO 2 (B), VO 2 (B) honeycombs and VO 2 (B) nanorods have been successfully fabricated through hydrothermal process by adjusting the concentrations of the oxalic acid. The microstructure and morphology of the VO 2 nanostructures were evaluated by using X-ray diffraction and scanning and transmission electron microscopies. Electrochemical properties measurements of urchin-like VO 2 (B) and VO 2 (B) honeycombs showed excellent cycling performance, especially the urchin-like VO 2 (B) exhibited higher discharge capacity and better capacity retention.

  3. A novel inorganic precipitation-peptization method for VO2 sol and VO2 nanoparticles preparation: Synthesis, characterization and mechanism.

    Science.gov (United States)

    Li, Yao; Jiang, Peng; Xiang, Wei; Ran, Fanyong; Cao, Wenbin

    2016-01-15

    In this paper, a simple, safe and cost-saving precipitation-peptization method was proposed to prepare VO2 sol by using inorganic VOSO4-NH3⋅H2O-H2O2 reactants system in air under room temperature. In this process, VOSO4 was firstly precipitated to form VO(OH)2, then monometallic species of VO(O2)(OH)(-) were formed through the coordination between VO(OH)2 and H2O2. The rearrangement of VO(O2)(OH)(-) in a nonplanar pattern and intermolecular condensation reactions result in multinuclear species. Finally, VO2 sol is prepared through the condensation reactions between the multinuclear species. After drying the obtained sol at 40°C, VO2 xerogel exhibiting monoclinic crystal structure with the space group of C2/m was prepared. The crystal structure of VO2 nanoparticles was transferred to monoclinic crystal structure with the space group of P21/c (VO2(M)) by annealing the xerogel at 550°C. Both XRD and TEM analysis indicated that the nanoparticles possess good crystallinity with crystallite size of 34.5nm as estimated by Scherrer's method. These results suggest that the VO2 sol has been prepared successfully through the proposed simple method. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Biochemical background of the VO2 on-kinetics in skeletal muscles.

    Science.gov (United States)

    Korzeniewski, Bernard; Zoladz, Jerzy A

    2006-02-01

    This review discusses the present knowledge on the oxygen uptake kinetics at the onset of exercise in skeletal muscle and the contribution of a previously developed computer model of oxidative phosphorylation in intact skeletal muscle to the understanding of the factors determining this kinetics on the biochemical level. It has been demonstrated recently that an increase in the total creatine pool [PCr + Cr] and in glycolytic ATP supply lengthen the half-transition time of the VO2 on-kinetics, while an increase in mitochondria content, in parallel activation of ATP supply and ATP usage, in muscle oxygen concentration, in proton leak, in resting energy demand, in resting cytosolic pH, and in initial alkalization diminish this parameter. It has also been shown that the half-transition time is near-linearly proportional to the absolute difference between the phosphocreatine concentration during work and at rest (deltaPCr). The present review discusses whether the V/O2 on-kinetics on the muscle level is strictly or only approximately exponential. Finally, it is postulated that a short transition time of the VO2 on-kinetics in itself does not need be profitable for the skeletal muscle functioning during exercise, but usually a short transition time is correlated with factors that improve exercise capacity. The transition time is a phenomenological parameter resulting from the biochemical properties of the system and not a physical factor that can cause anything in the system.

  5. Running Performance, VO2max, and Running Economy: The Widespread Issue of Endogenous Selection Bias.

    Science.gov (United States)

    Borgen, Nicolai T

    2018-05-01

    Studies in sport and exercise medicine routinely use samples of highly trained individuals in order to understand what characterizes elite endurance performance, such as running economy and maximal oxygen uptake VO 2max . However, it is not well understood in the literature that using such samples most certainly leads to biased findings and accordingly potentially erroneous conclusions because of endogenous selection bias. In this paper, I review the current literature on running economy and VO 2max , and discuss the literature in light of endogenous selection bias. I demonstrate that the results in a large part of the literature may be misleading, and provide some practical suggestions as to how future studies may alleviate endogenous selection bias.

  6. The electrochemical catalytic activity of single-walled carbon nanotubes towards VO2+/VO2+ and V3+/V2+ redox pairs for an all vanadium redox flow battery

    International Nuclear Information System (INIS)

    Li Wenyue; Liu Jianguo; Yan Chuanwei

    2012-01-01

    Highlights: ► SWCNT shows excellent electrochemical catalytic activity towards VO 2 + /VO 2+ and V 3+ /V 2+ redox couples. ► The anodic reactions are more sensitive to the surface oxygen atom content change compared with the cathodic reactions. ► The enhanced battery performance clearly demonstrated that the SWCNT is suitable to be used as an electrode catalyst for VRFB. - Abstract: Single-walled carbon nanotube (SWCNT) was used as an electrode catalyst for an all vanadium redox flow battery (VRFB). The electrochemical property of SWCNT towards VO 2 + /VO 2+ and V 3+ /V 2+ was carefully characterized by cyclic voltammetric (CV) and electrochemical impedance spectroscopy (EIS) measurements. The peak current values for these redox pairs were significantly higher on the modified glassy carbon electrode compared with those obtained on the bare electrode, suggesting the excellent electrochemical activity of the SWCNT. Moreover, it was proved that the anodic process was more dependent on the surface oxygen of the SWCNT than the cathodic process through changing its surface oxygen content. Detailed EIS analysis of different modified electrodes revealed that the charge and mass transfer processes were accelerated at the modified electrode–electrolyte interface, which could be ascribed to the large specific surface area, the surface defects and the oxygen functional groups of the SWCNT. The enhanced battery performance effectively demonstrated that the SWCNT was suitable to serve as an electrode catalyst for the VRFB.

  7. Effects of three warm-up regimens of equal distance on VO2 kinetics during supramaximal exercise in Thoroughbred horses.

    Science.gov (United States)

    Mukai, K; Hiraga, A; Takahashi, T; Ohmura, H; Jones, J H

    2010-11-01

    Several studies have indicated that even low-intensity warm-up increases O(2) transport kinetics and that high-intensity warm-up may not be needed in horses. However, conventional warm-up exercise for Thoroughbred races is more intense than those utilised in previous studies of equine warm-up responses. To test the hypothesis that warm-up exercise at different intensities alters the kinetics and total contribution of aerobic power to total metabolic power in subsequent supramaximal (sprint) exercise in Thoroughbred horses. Nine well-trained Thoroughbreds ran until fatigue at 115% of maximal oxygen consumption (VO2max) 10 min after warming-up under each of 3 protocols of equal running distance: 400 s at 30% VO2max (LoWU), 200 s at 60% VO2max (MoWU) and 120 s at 100% VO2max (HiWU). Variables measured during exercise were rates of O(2) and CO(2) consumption/production (VO2,VO2), respiratory exchange ratio (RER), heart rate, blood lactate concentration and accumulation rate and blood gas variables. VO2 was significantly higher in HiWU than in LoWU at the onset of the sprint exercise and HR was significantly higher in HiWU than in LoWU throughout the sprint. Accumulation of blood lactate, RER, P(a)CO(2) and PvCO2 in the first 60 s were significantly lower in HiWU than in LoWU and MoWU. There were no significant differences in stroke volume, run time or arterial-mixed venous O(2) concentration. These results suggest HiWU accelerates kinetics and reduces reliance on net anaerobic power compared with LoWU at the onset of the subsequent sprint. © 2010 EVJ Ltd.

  8. Variação diurna e resposta da cinética do VO2 de ciclistas durante exercício muito intenso Diurnal variation and Vo2 kinetic response of cyclists during heavy exercis e

    Directory of Open Access Journals (Sweden)

    Marcos G. Santana

    2008-06-01

    Full Text Available O objetivo do presente estudo foi avaliar a influência da hora do dia nos parâmetros da cinética do consumo de oxigênio de ciclistas durante exercício muito intenso. Nove voluntários do sexo masculino realizaram exercícios de carga constante às 08:00, 13:00 e 18:00 h, em dias diferentes. Estes exercícios foram realizados duas vezes em cada visita, com um intervalo de 1 h entre eles. A intensidade usada foi de 75%Δ (75% da diferença entre o VO2 no limiar de lactato e o VO2max. A amplitude do componente primário do VO2 (2597 ± 273 ml.min-1, 2513 ± 268 ml.min-1 e 2609 ± 370 ml.min-1, a constante de tempo do componente primário do VO2 (19.3 ± 2.5 s, 18.4 ± 3.0 s e 19.7 ± 3.9 s, o componente lento do VO2 (735 ± 81 ml.min-1, 764 ± 99 ml.min-1 e 680 ± 121 ml.min-1 e o tempo de resposta média (51.8 ± 4.2 s, 51.2 ± 4.2 s e 51.4 ± 3.4 s não apresentaram diferenças significativas entre os diferentes horários do dia (08:00, 13:00 e 18:00 h, assim como os demais parâmetros da cinética do VO2. Estes resultados sugerem que a resposta da cinética do VO2 de ciclistas durante exercício muito intenso (75%Δ não é influenciada pela hora do dia.The objective of the present study was to evaluate the influence of the time of day on the parameters of oxygen uptake kinetics of trained cyclists during high intensity exercise. Nine male volunteers repeated bouts at constant loads at 08:00, 13:00 and 18:00 h on different days. These exercise bouts were performed twice on each occasion, with an interval of 1 h between them. The load intensity used was 75%Δ (75% of the difference between the VO2 at the lactate threshold and the VO2max. The primary VO2 amplitude (2597 ± 273 ml.min-1, 2513 ± 268 ml.min-1 and 2609 ± 370 ml.min-1, the primary VO2 time constant (19.3 ± 2.5 s, 18.4 ± 3.0 s and 19.7 ± 3.9 s, the VO2 slow component (735 ± 81 ml.min-1, 764 ± 99 ml.min-1 and 680 ± 121 ml.min-1 and the mean response time (51.8 ± 4.2 s, 51

  9. Synthesis, characterization and formation mechanism of metastable phase VO2(A) nanorods

    International Nuclear Information System (INIS)

    Cheng, X.H.; Xu, H.F.; Wang, Z.Z.; Zhu, K.R.; Li, G.; Jin, Shaowei

    2013-01-01

    Graphical abstract: - Highlights: • Pure phases of VO 2 (B) and VO 2 (A) were prepared by a facile hydrothermal method. • Belt-like particles prepared at 180 °C was indexed as monoclinic VO 2 (B) phase. • Rod-like particles prepared at 230 °C was indexed as tetragonal VO 2 (A) phase. • VO 2 (A) nanorods resulted from VO 2 (B) nanobelts by assembly and crystal adjustment. - Abstract: Pure phase VO 2 (A) nanorods were synthesized via the reduction of V 2 O 5 by oxalic acid during the hydrothermal treatment. Two sets of samples were prepared by varying both system temperature and reaction time under a filling ratio of 0.40 for observing the formation and evolution of VO 2 (A) nanorods. Structures were characterized by X-ray diffraction, scanning and transmission electron microscopies, respectively. It was found that VO 2 (B) was firstly formed and then transformed into VO 2 (A) as the increasing system temperature or extending reaction time. An assembling and following crystal adjustment was proposed for explanation the formation process of VO 2 (A) from VO 2 (B). For VO 2 (A) nanorods, the phase transition temperature of 169.7 °C was higher than that of the VO 2 (A) bulk, it might be ascribed to the lower crystallinity or nonstoichiometry in VO 2 (A) nanorods. VO 2 nanostructures with controllable phases and properties should find their promising applications in a single VO 2 nanodevice

  10. Electronic structure and insulating gap in epitaxial VO2 polymorphs

    Directory of Open Access Journals (Sweden)

    Shinbuhm Lee

    2015-12-01

    Full Text Available Determining the origin of the insulating gap in the monoclinic V O2(M1 is a long-standing issue. The difficulty of this study arises from the simultaneous occurrence of structural and electronic transitions upon thermal cycling. Here, we compare the electronic structure of the M1 phase with that of single crystalline insulating V O2(A and V O2(B thin films to better understand the insulating phase of VO2. As these A and B phases do not undergo a structural transition upon thermal cycling, we comparatively study the origin of the gap opening in the insulating VO2 phases. By x-ray absorption and optical spectroscopy, we find that the shift of unoccupied t2g orbitals away from the Fermi level is a common feature, which plays an important role for the insulating behavior in VO2 polymorphs. The distinct splitting of the half-filled t2g orbital is observed only in the M1 phase, widening the bandgap up to ∼0.6 eV. Our approach of comparing all three insulating VO2 phases provides insight into a better understanding of the electronic structure and the origin of the insulating gap in VO2.

  11. Exercise-induced prostacyclin release positively correlates with VO(2max) in young healthy men.

    Science.gov (United States)

    Zoladz, J A; Majerczak, J; Duda, K; Chłopicki, S

    2009-01-01

    In this study we have evaluated the effect of maximal incremental cycling exercise (IE) on the systemic release of prostacyclin (PGI(2)), assessed as plasma 6-keto-PGF(1alpha) concentration in young healthy men. Eleven physically active - untrained men (mean +/- S.D.) aged 22.7 +/- 2.1 years; body mass 76.3 +/- 9.1 kg; BMI 23.30 +/- 2.18 kg . m(-2); maximal oxygen uptake (VO(2max)) 46.5 +/- 3.9 ml . kg(-1) . min(-1), performed an IE test until exhaustion. Plasma concentrations of 6-keto-PGF(1alpha), lactate, and cytokines were measured in venous blood samples taken prior to the exercise and at the exhaustion. The net exercise-induced increase in 6-keto-PGF(1alpha) concentration, expressed as the difference between the end-exercise minus pre-exercise concentration positively correlated with VO(2max) (r=0.78, p=0.004) as well as with the net VO(2) increase at exhaustion (r=0.81, p=0.003), but not with other respiratory, cardiac, metabolic or inflammatory parameters of the exercise (minute ventilation, heart rate, plasma lactate, IL-6 or TNF-alpha concentrations). The exercise-induced increase in 6-keto-PGF(1alpha) concentration?? was significantly higher (p=0.008) in a group of subjects (n=5) with the highest VO(2max) when compared to the group of subjects with the lowest VO(2max), in which no increase in 6-keto-PGF(1alpha) concentration was found. In conclusion, we demonstrated, to our knowledge for the first time, that exercise-induced release of PGI(2) in young healthy men correlates with VO(2max), suggesting that vascular capacity to release PGI(2) in response to physical exercise represents an important factor characterizing exercise tolerance. Moreover, we postulate that the impairment of exercise-induced release of PGI(2) leads to the increased cardiovascular hazard of vigorous exercise.

  12. Mechanisms of Attenuation of Pulmonary V'O2 Slow Component in Humans after Prolonged Endurance Training.

    Directory of Open Access Journals (Sweden)

    Jerzy A Zoladz

    Full Text Available In this study we have examined the effect of prolonged endurance training program on the pulmonary oxygen uptake (V'O2 kinetics during heavy-intensity cycling-exercise and its impact on maximal cycling and running performance. Twelve healthy, physically active men (mean±SD: age 22.33±1.44 years, V'O2peak 3198±458 mL ∙ min-1 performed an endurance training composed mainly of moderate-intensity cycling, lasting 20 weeks. Training resulted in a decrease (by ~5%, P = 0.027 in V'O2 during prior low-intensity exercise (20 W and in shortening of τp of the V'O2 on-kinetics (30.1±5.9 s vs. 25.4±1.5 s, P = 0.007 during subsequent heavy-intensity cycling. This was accompanied by a decrease of the slow component of V'O2 on-kinetics by 49% (P = 0.001 and a decrease in the end-exercise V'O2 by ~5% (P = 0.005. An increase (P = 0.02 in the vascular endothelial growth factor receptor 2 mRNA level and a tendency (P = 0.06 to higher capillary-to-fiber ratio in the vastus lateralis muscle were found after training (n = 11. No significant effect of training on the V'O2peak was found (P = 0.12. However, the power output reached at the lactate threshold increased by 19% (P = 0.01. The power output obtained at the V'O2peak increased by 14% (P = 0.003 and the time of 1,500-m performance decreased by 5% (P = 0.001. Computer modeling of the skeletal muscle bioenergetic system suggests that the training-induced decrease in the slow component of V'O2 on-kinetics found in the present study is mainly caused by two factors: an intensification of the each-step activation (ESA of oxidative phosphorylation (OXPHOS complexes after training and decrease in the ''additional" ATP usage rising gradually during heavy-intensity exercise.

  13. Mechanisms of Attenuation of Pulmonary V'O2 Slow Component in Humans after Prolonged Endurance Training.

    Science.gov (United States)

    Zoladz, Jerzy A; Majerczak, Joanna; Grassi, Bruno; Szkutnik, Zbigniew; Korostyński, Michał; Gołda, Sławomir; Grandys, Marcin; Jarmuszkiewicz, Wiesława; Kilarski, Wincenty; Karasinski, Janusz; Korzeniewski, Bernard

    2016-01-01

    In this study we have examined the effect of prolonged endurance training program on the pulmonary oxygen uptake (V'O2) kinetics during heavy-intensity cycling-exercise and its impact on maximal cycling and running performance. Twelve healthy, physically active men (mean±SD: age 22.33±1.44 years, V'O2peak 3198±458 mL ∙ min-1) performed an endurance training composed mainly of moderate-intensity cycling, lasting 20 weeks. Training resulted in a decrease (by ~5%, P = 0.027) in V'O2 during prior low-intensity exercise (20 W) and in shortening of τp of the V'O2 on-kinetics (30.1±5.9 s vs. 25.4±1.5 s, P = 0.007) during subsequent heavy-intensity cycling. This was accompanied by a decrease of the slow component of V'O2 on-kinetics by 49% (P = 0.001) and a decrease in the end-exercise V'O2 by ~5% (P = 0.005). An increase (P = 0.02) in the vascular endothelial growth factor receptor 2 mRNA level and a tendency (P = 0.06) to higher capillary-to-fiber ratio in the vastus lateralis muscle were found after training (n = 11). No significant effect of training on the V'O2peak was found (P = 0.12). However, the power output reached at the lactate threshold increased by 19% (P = 0.01). The power output obtained at the V'O2peak increased by 14% (P = 0.003) and the time of 1,500-m performance decreased by 5% (P = 0.001). Computer modeling of the skeletal muscle bioenergetic system suggests that the training-induced decrease in the slow component of V'O2 on-kinetics found in the present study is mainly caused by two factors: an intensification of the each-step activation (ESA) of oxidative phosphorylation (OXPHOS) complexes after training and decrease in the ''additional" ATP usage rising gradually during heavy-intensity exercise.

  14. Escala de VO2pico em adolescentes obesos e não-Obesos por diferentes métodos Escala de VO2pico en adolescentes obesos y no obesos por diferentes métodos Scale of VO2peak in obese and non-obese adolescents by different methods

    Directory of Open Access Journals (Sweden)

    Gerusa Eisfeld Milano

    2009-12-01

    estrategia atractiva para comparar individuos con grandes diferencias en la masa corporal. OBJETIVO: Investigar el VO2pico en individuos obesos y no obesos usando el método de corrección de masa corporal (convencional y la escala alométrica (método alométrico y cómo esos métodos se aplican cuando individuos de ambos sexos se ejercitan en una cinta ergométrica. MÉTODOS: El VO2pico relativo al peso corporal y por el método alométrico fue comparado en 54 adolescentes obesos y 33 no obesos (10-16 años. Para evaluar el VO2pico durante un test máximo se utilizó calorimetría indirecta. El exponente alométrico fue calculado considerando la masa corporal individual. Así, el VO2pico fue corregido mediante el exponente alométrico. Las comparaciones se realizaron utilizando two-way ANOVA para medidas repetidas (p0,05. Sin embargo, el VO2pico calculado por el método convencional fue mayor (p0.05 entre los grupos. CONCLUSIÓN: Los individuos obesos presentaron VO2pico más bajo que los no obesos, al ser evaluados mediante el método convencional. Sin embargo, las diferencias desaparecieron cuando se aplicó el método de la escala alométrica.BACKGROUND: Peak oxygen uptake (VO2peak can be defined as the highest oxygen rate consumed during exhaustive or maximal exercise. The evaluation of the aerobic fitness can be expressed as relative to body mass, but this procedure may not fully remove differences when heavy subjects are assessed. Thus, the allometric scaling procedure is an attractive strategy to compare individuals with large differences in body mass. OBJECTIVE: Investigate VO2peak in obese and non-obese individuals using body mass correction (conventional and allometric scaling (allometric methods and how these methods apply when subjects of different genders exercise on a treadmill. METHODS: VO2peak relative to body weight and measured by the allometric method were compared in 54 obese and 33 non-obese adolescents (10 a 16 years. Indirect calorimetry was used to

  15. Comprehensive picture of VO2 from band theory

    KAUST Repository

    Zhu, Zhiyong; Schwingenschlö gl, Udo

    2012-01-01

    The structural, electronic, and magnetic features of the metal-insulator transition from the tetragonal rutile (R) to the monoclinic (M1) phase of VO2 are well reproduced by band theory using the modified Becke-Johnson exchange potential. Based

  16. Initial Weekly HRV Response is Related to the Prospective Change in VO2max in Female Soccer Players.

    Science.gov (United States)

    Esco, M R; Flatt, A A; Nakamura, F Y

    2016-06-01

    The aim of this study was to determine whether the early response in weekly measures of HRV, when derived from a smartphone application, were related to the eventual change in VO2max following an off-season training program in female soccer athletes. 9 female collegiate soccer players participated in an 11-week off-season conditioning program. In the week immediately before and after the training program, each participant performed a test on a treadmill to determine maximal oxygen consumption (VO2max). Daily measures of the log-transformed root mean square of successive R-R intervals (lnRMSSD) were performed by the participants throughout week 1 and week 3 of the conditioning program. The mean and coefficient of variation (CV) lnRMSSD values of week 1 showed small (r=- 0.13, p=0.74) and moderate (r=0.57, p=0.11), respectively, non-significant correlations to the change in VO2max at the end of the conditioning program (∆VO2max). Significant and near-perfect correlation was found between the change in the weekly mean lnRMSSD values from weeks 1 and 3 (∆lnRMSSDM) and ∆VO2max (r=0.90, p=0.002). The current results have identified that the initial change in weekly mean lnRMSSD from weeks 1 to 3 of a conditioning protocol was strongly associated with the eventual adaptation of VO2max. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Lithiation-driven structural transition of VO2F into disordered rock-salt LixVO2F

    Czech Academy of Sciences Publication Activity Database

    Chen, R.; Maawad, E.; Knapp, M.; Ren, S.; Beran, Přemysl; Witter, R.; Hempelmann, R.

    2016-01-01

    Roč. 6, č. 69 (2016), s. 65112-65118 ISSN 2046-2069 R&D Projects: GA MŠk(CZ) LM2011019 EU Projects: European Commission(XE) 283883 - NMI3-II Institutional support: RVO:61389005 Keywords : Li- Ion batteries * rechargeble lithium batteries * VO2F Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.108, year: 2016

  18. Structure of Co(2), Ni(2) and VO(2) complexes with 4-phenylthiosemicarbaziddiacetic acid

    International Nuclear Information System (INIS)

    Kravtsov, V.Kh.; Kipkovskij, Ya.; Bologa, O.A.; Lozan, V.I.; Simonov, Yu.A.; Gehrbehlehu, N.V.; Malinovskij, T.I.; AN Moldavskoj SSR, Kishinev

    1995-01-01

    Structure of complex compounds VO(2)(3) with 4-phyenylthiosemicarbaziddiacetic acid is determined through X-ray diffraction method. Monocrystal compounds are monoclinic, sp.gr. P2 1 /n (a=6.703(2), b=12.470(7), c=1695(6) A, γ=95.10(4) deg). The organic molecule in the complexes is expressed in form of twofold deprotonated tetradentate, ligand joining to metal according to the tripod type with application of donor atoms S, N, O, O and forming three metallocycles. The coordination surrounding of the central atom is supplemented by one oxygen vanadyl atom and one water molecule. 17 refs.; 4 figs.; 5 tabs

  19. Possible factors determining the non-linearity in the VO2-power output relationship in humans: theoretical studies.

    Science.gov (United States)

    Korzeniewski, Bernard; Zoladz, Jerzy A

    2003-08-01

    At low power output exercise (below lactate threshold), the oxygen uptake increases linearly with power output, but at high power output exercise (above lactate threshold) some additional oxygen consumption causes a non-linearity in the overall VO(2) (oxygen uptake rate)-power output relationship. The functional significance of this phenomenon for human exercise tolerance is very important, but the mechanisms underlying it remain unknown. In the present work, a computer model of oxidative phosphorylation in intact skeletal muscle developed previously is used to examine the background of this relationship in different modes of exercise. Our simulations demonstrate that the non-linearity in the VO(2)-power output relationship and the difference in the magnitude of this non-linearity between incremental exercise mode and square-wave exercise mode (constant power output exercise) can be generated by introducing into the model some hypothetical factor F (group of associated factors) that accumulate(s) in time during exercise. The performed computer simulations, based on this assumption, give proper time courses of changes in VO(2) and [PCr] after an onset of work of different intensities, including the slow component in VO(2), well matching the experimental results. Moreover, if it is assumed that the exercise terminates because of fatigue when the amount/intensity of F exceed some threshold value, the model allows the generation of a proper shape of the well-known power-duration curve. This fact suggests that the phenomenon of the non-linearity of the VO(2)-power output relationship and the magnitude of this non-linearity in different modes of exercise is determined by some factor(s) responsible for muscle fatigue.

  20. VO2 thermochromic smart window for energy savings and generation

    Science.gov (United States)

    Zhou, Jiadong; Gao, Yanfeng; Zhang, Zongtao; Luo, Hongjie; Cao, Chuanxiang; Chen, Zhang; Dai, Lei; Liu, Xinling

    2013-10-01

    The ability to achieve energy saving in architectures and optimal solar energy utilisation affects the sustainable development of the human race. Traditional smart windows and solar cells cannot be combined into one device for energy saving and electricity generation. A VO2 film can respond to the environmental temperature to intelligently regulate infrared transmittance while maintaining visible transparency, and can be applied as a thermochromic smart window. Herein, we report for the first time a novel VO2-based smart window that partially utilises light scattering to solar cells around the glass panel for electricity generation. This smart window combines energy-saving and generation in one device, and offers potential to intelligently regulate and utilise solar radiation in an efficient manner.

  1. Gate-tunable gigantic lattice deformation in VO2

    International Nuclear Information System (INIS)

    Okuyama, D.; Hatano, T.; Nakano, M.; Takeshita, S.; Ohsumi, H.; Tardif, S.; Shibuya, K.; Yumoto, H.; Koyama, T.; Ohashi, H.; Takata, M.; Kawasaki, M.; Tokura, Y.; Iwasa, Y.; Arima, T.

    2014-01-01

    We examined the impact of electric field on crystal lattice of vanadium dioxide (VO 2 ) in a field-effect transistor geometry by in-situ synchrotron x-ray diffraction measurements. Whereas the c-axis lattice parameter of VO 2 decreases through the thermally induced insulator-to-metal phase transition, the gate-induced metallization was found to result in a significant increase of the c-axis length by almost 1% from that of the thermally stabilized insulating state. We also found that this gate-induced gigantic lattice deformation occurs even at the thermally stabilized metallic state, enabling dynamic control of c-axis lattice parameter by more than 1% at room temperature

  2. Preparation and modification of VO2 thin film on R-sapphire substrate by rapid thermal process

    Science.gov (United States)

    Zhu, Nai-Wei; Hu, Ming; Xia, Xiao-Xu; Wei, Xiao-Ying; Liang, Ji-Ran

    2014-04-01

    The VO2 thin film with high performance of metal-insulator transition (MIT) is prepared on R-sapphire substrate for the first time by magnetron sputtering with rapid thermal process (RTP). The electrical characteristic and THz transmittance of MIT in VO2 film are studied by four-point probe method and THz time domain spectrum (THz-TDS). X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and search engine marketing (SEM) are employed to analyze the crystalline structure, valence state, surface morphology of the film. Results indicate that the properties of VO2 film which is oxidized from the metal vanadium film in oxygen atmosphere are improved with a follow-up RTP modification in nitrogen atmosphere. The crystallization and components of VO2 film are improved and the film becomes compact and uniform. A better phase transition performance is shown that the resistance changes nearly 3 orders of magnitude with a 2-°C hysteresis width and the THz transmittances are reduced by 64% and 60% in thermal and optical excitation respectively.

  3. Preparation and modification of VO2 thin film on R-sapphire substrate by rapid thermal process

    International Nuclear Information System (INIS)

    Zhu Nai-Wei; Hu Ming; Xia Xiao-Xu; Wei Xiao-Ying; Liang Ji-Ran

    2014-01-01

    The VO 2 thin film with high performance of metal–insulator transition (MIT) is prepared on R-sapphire substrate for the first time by magnetron sputtering with rapid thermal process (RTP). The electrical characteristic and THz transmittance of MIT in VO 2 film are studied by four-point probe method and THz time domain spectrum (THz-TDS). X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and search engine marketing (SEM) are employed to analyze the crystalline structure, valence state, surface morphology of the film. Results indicate that the properties of VO 2 film which is oxidized from the metal vanadium film in oxygen atmosphere are improved with a follow-up RTP modification in nitrogen atmosphere. The crystallization and components of VO 2 film are improved and the film becomes compact and uniform. A better phase transition performance is shown that the resistance changes nearly 3 orders of magnitude with a 2-°C hysteresis width and the THz transmittances are reduced by 64% and 60% in thermal and optical excitation respectively. (interdisciplinary physics and related areas of science and technology)

  4. Positron annihilation in single crystals of TiO2, VO2, Pb, and U

    International Nuclear Information System (INIS)

    Blau, M.

    1982-09-01

    Two positron annihilation set-ups for Doppler broadening correlation measurements are described. The Doppler broadening spectra were measured in different directions of single crystals of TiO 2 and VO 2 , at room temperature. The anisotropy was explained using two models in which the positron behaves as a free or bounded particle, and was related to the effective charge on the oxygen ion. The changes in the spectra in VO 2 , on passing from the insulator to the metal phase, were found to be gradual and small. The results indicate that the main contribution to the metal-insulator transition is due to changes in the relative occupation of the oxygen p-states and not to changes in covalency or screening. Angular correlations were measured in single crystals of lead in three crystallographic directions. The derivatives of the spectra were compared with the Fermi surface obtained from dHvA measurements, using plane-wave electrons. Most of the features of the experimental derivatives were explained with this simple model. Angular correlation measurements were made on single crystals of uranium in two crystallographic directions. The derivates of the spectra were very wide with a few peaks. (Author)

  5. Supercapacitors based on two dimensional VO2 nanosheet electrodes in organic gel electrolyte

    KAUST Repository

    Baby, Rakhi Raghavan; Nagaraju, Doddahalli H.; Beaujuge, Pierre; Alshareef, Husam N.

    2016-01-01

    VO2 is a low band-gap semiconductor with relatively high conductivity among transition metal oxides, which makes it an interesting material for supercapacitor electrode applications. The performance of VO2 as supercapacitor electrode in organic

  6. HIGHER PRECISION OF HEART RATE COMPARED WITH VO2 TO PREDICT EXERCISE INTENSITY IN ENDURANCE-TRAINED RUNNERS

    Directory of Open Access Journals (Sweden)

    Victor M. Reis

    2011-03-01

    Full Text Available The aim of the present study was to assess the precision of oxygen uptake with heart rate regression during track running in highly-trained runners. Twelve national and international level male long-distance road runners (age 30.7 ± 5.5 yrs, height 1.71 ± 0.04 m and mass 61.2 ± 5.8 kg with a personal best on the half marathon of 62 min 37 s ± 1 min 22 s participated in the study. Each participant performed, in an all-weather synthetic track five, six min bouts at constant velocity with each bout at an increased running velocity. The starting velocity was 3.33 m·s-1 with a 0.56 m·s-1 increase on each subsequent bout. VO2 and heart rate were measured during the runs and blood lactate was assessed immediately after each run. Mean peak VO2 and mean peak heart rate were, respectively, 76.2 ± 9.7 mL·kg-1·min-1 and 181 ± 13 beats·min-1. The linearity of the regressions between heart rate, running velocity and VO2 were all very high (r > 0.99 with small standard errors of regression (i.e. Sy.x < 5% at the velocity associated with the 2 and 4 mmol·L-1 lactate thresholds. The strong relationships between heart rate, running velocity and VO2 found in this study show that, in highly trained runners, it is possible to have heart rate as an accurate indicator of energy demand and of the running speed. Therefore, in this subject cohort it may be unnecessary to use VO2 to track changes in the subjects' running economy during training periods.

  7. Effects of chronic nitric oxide synthase inhibition on V'O2max and exercise capacity in mice.

    Science.gov (United States)

    Wojewoda, M; Przyborowski, K; Sitek, B; Zakrzewska, A; Mateuszuk, L; Zoladz, J A; Chlopicki, S

    2017-03-01

    Acute inhibition of NOS by L-NAME (N ω -nitro-L-arginine methyl ester) is known to decrease maximal oxygen consumption (V'O 2max ) and impair maximal exercise capacity, whereas the effects of chronic L-NAME treatment on V'O 2max and exercise performance have not been studied so far. In this study, we analysed the effect of L-NAME treatment, (LN2 and LN12, respectively) on V'O 2max and exercise capacity (in maximal incremental running and prolonged sub-maximal incremental running tests), systemic NO bioavailability (plasma nitrite (NO 2 - ) and nitrate (NO 3 - )) and prostacyclin (PGI 2 ) production in C57BL6/J mice. Mice treated with L-NAME for 2 weeks (LN2) displayed higher V'O 2max and better running capacity than age-matched control mice. In LN2 mice, NO bioavailability was preserved, as evidenced by maintained NO 2 - plasma concentration. PGI 2 production was activated (increased 6-keto-PGF 1α plasma concentration) and the number of circulating erythrocytes (RBC) and haemoglobin concentration were increased. In mice treated with L-NAME for 12 weeks (LN12), NO bioavailability was decreased (lower NO 2 - plasma concentration), and 6-keto-PGF 1α plasma concentration and RBC number were not elevated compared to age-matched control mice. However, LN12 mice still performed better during the maximal incremental running test despite having lower V'O 2max . Interestingly, the LN12 mice showed poorer running capacity during the prolonged sub-maximal incremental running test. To conclude, short-term (2 weeks) but not long-term (12 weeks) treatment with L-NAME activated robust compensatory mechanisms involving preservation of NO2- plasma concentration, overproduction of PGI 2 and increased number of RBCs, which might explain the fully preserved exercise capacity despite the inhibition of NOS.

  8. Endurance training increases exercise-induced prostacyclin release in young, healthy men--relationship with VO2max.

    Science.gov (United States)

    Zoladz, Jerzy A; Majerczak, Joanna; Duda, Krzysztof; Chłopicki, Stefan

    2010-01-01

    In the present study, we evaluated the effect of 5 weeks of moderate-intensity endurance training on the basal and exercise-induced systemic release of prostacyclin (PGI(2)), as assessed by plasma 6-keto-PGF(1 alpha) concentration. Twelve physically active young men with the following characteristics participated in this study (the mean +/- SD): age, 22.7 +/- 2.0 years; body mass, 76.8 +/- 8.9 kg; BMI, 23.48 +/- 2.17 kg x m(-2); and maximal oxygen uptake (VO(2 max)), 46.1 +/- 4.0 ml x kg(-1) x min(-1). Plasma 6-keto-PGF(1 alpha) concentrations were measured in venous blood samples taken prior to the exercise and at exhaustion (at VO(2 max)) before and after completing the training protocol. On average, the training resulted in a significant increase in VO(2 max) (p = 0.03), power output at VO(2 max) (p = 0.001) and a significant increase (p = 0.05) in the net-exercise-induced increase in plasma 6-keto-PGF(1 alpha) concentration (Delta 6-keto-PGF(1 alpha) i.e., the difference between the end-exercise and pre-exercise 6-keto-PGF(1 alpha) concentrations). No effect of training on the basal PGI(2) concentration was found. Interestingly, within the study sample (n = 12), two subgroups could be defined with a differential pattern of response with respect to Delta 6-keto-PGF(1 alpha) concentrations. In one subgroup (n = 7), a significant increase in Delta 6-keto-PGF(1 alpha) concentration after training was found (p < 0.02) (responders). This enhancement in the exercise-induced PGI(2) release was accompanied by a significant (p < 0.05) increase in VO(2 max) after training. In contrast, in another subgroup (n = 5), there was no observed effect of training on the Delta 6-keto-PGF(1 alpha) concentration and the VO(2 max) after training (non-responders). In both of these subgroups, training did not influence the basal PGI(2) concentration. In conclusion, the endurance training resulted in the adaptive augmentation of the systemic release of PGI(2) in response to exercise

  9. Ultrafast dynamics during the photoinduced phase transition in VO2

    Science.gov (United States)

    Wegkamp, Daniel; Stähler, Julia

    2015-12-01

    The phase transition of VO2 from a monoclinic insulator to a rutile metal, which occurs thermally at TC = 340 K, can also be driven by strong photoexcitation. The ultrafast dynamics during this photoinduced phase transition (PIPT) have attracted great scientific attention for decades, as this approach promises to answer the question of whether the insulator-to-metal (IMT) transition is caused by electronic or crystallographic processes through disentanglement of the different contributions in the time domain. We review our recent results achieved by femtosecond time-resolved photoelectron, optical, and coherent phonon spectroscopy and discuss them within the framework of a selection of latest, complementary studies of the ultrafast PIPT in VO2. We show that the population change of electrons and holes caused by photoexcitation launches a highly non-equilibrium plasma phase characterized by enhanced screening due to quasi-free carriers and followed by two branches of non-equilibrium dynamics: (i) an instantaneous (within the time resolution) collapse of the insulating gap that precedes charge carrier relaxation and significant ionic motion and (ii) an instantaneous lattice potential symmetry change that represents the onset of the crystallographic phase transition through ionic motion on longer timescales. We discuss the interconnection between these two non-thermal pathways with particular focus on the meaning of the critical fluence of the PIPT in different types of experiments. Based on this, we conclude that the PIPT threshold identified in optical experiments is most probably determined by the excitation density required to drive the lattice potential change rather than the IMT. These considerations suggest that the IMT can be driven by weaker excitation, predicting a transiently metallic, monoclinic state of VO2 that is not stabilized by the non-thermal structural transition and, thus, decays on ultrafast timescales.

  10. Comprehensive picture of VO2 from band theory

    KAUST Repository

    Zhu, Zhiyong

    2012-08-28

    The structural, electronic, and magnetic features of the metal-insulator transition from the tetragonal rutile (R) to the monoclinic (M1) phase of VO2 are well reproduced by band theory using the modified Becke-Johnson exchange potential. Based on this description, we identify a tendency for monoclinic charge ordering in the R phase due to electronic correlations as the origin of the phase transition. Whereas, the structural changes are crucial for the gap opening in the M1 phase, spin degeneracy in both phases is stabilized by correlation-induced delocalization of the V3d electrons.

  11. The impact of acute bouts of interval and continuous walking on energy-intake and appetite regulation in subjects with type 2 diabetes

    DEFF Research Database (Denmark)

    Müller, Ida A; Wedell-Neergaard, Anne-Sophie; Solomon, Thomas P J

    2017-01-01

    In healthy subjects, it has been suggested that exercise may acutely suppress energy-intake and appetite, with peak intensity being an important determinant for this effect. In subjects with type 2 diabetes (T2D), the effect of exercise on appetite-related variables is, however, virtually unknown....... We aimed to assess the effects of two exercise interventions, differing with regards to peak intensity, on energy-intake, satiety and appetite-related hormones in subjects with T2D. Thirteen subjects with T2D completed three 60-min interventions with continuous measurement of oxygen consumption...... in a randomized and counterbalanced order: (1) Control, (2) Continuous walking (CW; intended 73% of VO2peak), (3) Interval-walking (IW; repeated cycles of 3 min slow [54% of VO2peak] and 3 min fast walking [89% of VO2peak]). Forty-five minutes after completion of the intervention, a 3-h liquid mixed meal...

  12. Elevated transition temperature in Ge doped VO2 thin films

    Science.gov (United States)

    Krammer, Anna; Magrez, Arnaud; Vitale, Wolfgang A.; Mocny, Piotr; Jeanneret, Patrick; Guibert, Edouard; Whitlow, Harry J.; Ionescu, Adrian M.; Schüler, Andreas

    2017-07-01

    Thermochromic GexV1-xO2+y thin films have been deposited on Si (100) substrates by means of reactive magnetron sputtering. The films were then characterized by Rutherford backscattering spectrometry (RBS), four-point probe electrical resistivity measurements, X-ray diffraction, and atomic force microscopy. From the temperature dependent resistivity measurements, the effect of Ge doping on the semiconductor-to-metal phase transition in vanadium oxide thin films was investigated. The transition temperature was shown to increase significantly upon Ge doping (˜95 °C), while the hysteresis width and resistivity contrast gradually decreased. The precise Ge concentration and the film thickness have been determined by RBS. The crystallinity of phase-pure VO2 monoclinic films was confirmed by XRD. These findings make the use of vanadium dioxide thin films in solar and electronic device applications—where higher critical temperatures than 68 °C of pristine VO2 are needed—a viable and promising solution.

  13. Higher Precision of Heart Rate Compared with VO2 to Predict Exercise Intensity in Endurance-Trained Runners.

    Science.gov (United States)

    Reis, Victor M; den Tillaar, Roland Van; Marques, Mario C

    2011-01-01

    The aim of the present study was to assess the precision of oxygen uptake with heart rate regression during track running in highly-trained runners. Twelve national and international level male long-distance road runners (age 30.7 ± 5.5 yrs, height 1.71 ± 0.04 m and mass 61.2 ± 5.8 kg) with a personal best on the half marathon of 62 min 37 s ± 1 min 22 s participated in the study. Each participant performed, in an all-weather synthetic track five, six min bouts at constant velocity with each bout at an increased running velocity. The starting velocity was 3.33 m·s(-1) with a 0.56 m·s(-1) increase on each subsequent bout. VO2 and heart rate were measured during the runs and blood lactate was assessed immediately after each run. Mean peak VO2 and mean peak heart rate were, respectively, 76.2 ± 9.7 mL·kg(-1)·min(-1) and 181 ± 13 beats·min(-1). The linearity of the regressions between heart rate, running velocity and VO2 were all very high (r > 0.99) with small standard errors of regression (i.e. Sy.x at the velocity associated with the 2 and 4 mmol·L(-1) lactate thresholds). The strong relationships between heart rate, running velocity and VO2 found in this study show that, in highly trained runners, it is possible to have heart rate as an accurate indicator of energy demand and of the running speed. Therefore, in this subject cohort it may be unnecessary to use VO2 to track changes in the subjects' running economy during training periods. Key pointsHeart rate is used in the control of exercise intensity in endurance sports.However, few studies have quantified the precision of its relationship with oxygen uptake in highly trained runners.We evaluated twelve elite half-marathon runners during track running at various intensities and established three regressions: oxygen uptake / heart rate; heart rate / running velocity and oxygen uptake / running velocity.The three regressions presented, respectively, imprecision of 4,2%, 2,75% and 4,5% at the velocity

  14. Crystallization Mechanism and Phase Transition Properties of W-doped VO2 Synthesized by Hydrothermal Method

    Directory of Open Access Journals (Sweden)

    LI Yao

    2017-11-01

    Full Text Available VO2 sol was firstly prepared using vanadyl sulfate as a vanadium source by precipitation-peptization method. Then tungsten(W doping vanadium dioxide(W-VO2 was prepared by hydrothermal crystallization of prepared sol with the presence of ammonium metatungstate. The morphologies, crystal structure of the as-prepared samples and phase transition properties were studied by X-ray diffraction(XRD, field emission scanning electron microscope(FESEMand differential scanning calorimetry(DSC analysis. The results indicate that rod-like W-VO2(B crystal with length of 1-2μm and radius of 100-200nm is firstly formed during hydrothermal treatment for 4-48h at 280℃, then the rod-like crystal dissolves gradually and sheet-like or snowflake-like crystal is formed with the phase transition from W-VO2(B to W-VO2(M and eventually, the W-VO2(M crystals can further grow up while the W-VO2(B gradually dissolves; the phase transition temperature of VO2 decreases with the increase in W doping content, and the phase transition temperature of W-VO2(M reduces to about 28℃ when the nominal dopant concentration is 6.0%(atom fraction.The "nucleation-growth-transformation-ripening" mechanism is proposed as the formation mechanism based on the hydrothermal crystallization and morphological evolution process of W-VO2(M.

  15. The role of haemoglobin mass on VO(2)max following normobaric 'live high-train low' in endurance-trained athletes

    DEFF Research Database (Denmark)

    Robach, Paul; Siebenmann, Christoph; Jacobs, Robert A

    2012-01-01

    It remains unclear by which mechanism 'live high-train low' (LHTL) altitude training increases exercise performance. Haematological and skeletal muscle adaptations have both been proposed. To test the hypotheses that (i) LHTL improves maximal oxygen uptake (VO(2)max) and (ii) this improvement is ...

  16. Progressive recruitment of muscle fibers is not necessary for the slow component of VO2 kinetics.

    Science.gov (United States)

    Zoladz, Jerzy A; Gladden, L Bruce; Hogan, Michael C; Nieckarz, Zenon; Grassi, Bruno

    2008-08-01

    The "slow component" of O2 uptake (VO2) kinetics during constant-load heavy-intensity exercise is traditionally thought to derive from a progressive recruitment of muscle fibers. In this study, which represents a reanalysis of data taken from a previous study by our group (Grassi B, Hogan MC, Greenhaff PL, Hamann JJ, Kelley KM, Aschenbach WG, Constantin-Teodosiu D, Gladden LB. J Physiol 538: 195-207, 2002) we evaluated the presence of a slow component-like response in the isolated dog gastrocnemius in situ (n=6) during 4 min of contractions at approximately 60-70% of peak VO2. In this preparation all muscle fibers are maximally activated by electrical stimulation from the beginning of the contraction period, and no progressive recruitment of fibers is possible. Muscle VO2 was calculated as blood flow multiplied by arteriovenous O2 content difference. The muscle fatigued (force decreased by approximately 20-25%) during contractions. Kinetics of adjustment were evaluated for 1) VO2, uncorrected for force development; 2) VO2 normalized for peak force; 3) VO2 normalized for force-time integral. A slow component-like response, described in only one muscle out of six when uncorrected VO2 was considered, was observed in all muscles when VO2/peak force and VO2/force-time were considered. The amplitude of the slow component-like response, expressed as a fraction of the total response, was higher for VO2/peak force (0.18+/-0.06, means+/-SE) and for VO2/force-time (0.22+/-0.05) compared with uncorrected VO2 (0.04+/-0.04). A progressive recruitment of muscle fibers may not be necessary for the development of the slow component of VO2 kinetics, which may be caused by the metabolic factors that induce muscle fatigue and, as a consequence, reduce the efficiency of muscle contractions.

  17. Voluntary feed intake in rainbow trout is regulated by diet-induced differences in oxygen use.

    Science.gov (United States)

    Saravanan, Subramanian; Geurden, Inge; Figueiredo-Silva, A Cláudia; Kaushik, Sadasivam; Verreth, Johan; Schrama, Johan W

    2013-06-01

    This study investigated the hypothesis that the voluntary feed intake in fish is regulated by diet-induced differences in oxygen use. Four diets were prepared with a similar digestible protein:digestible energy ratio (18 mg/kJ), but which differed in the composition of nonprotein energy source. This replacement of fat (F) by starch (S) was intended to create a diet-induced difference in oxygen use (per unit of feed): diets F30-S70, F50-S50, F65-S35, and F80-S20 with digestible fat providing 28, 49, 65, and 81% of the nonprotein digestible energy (NPDE), respectively. Each diet was fed to satiation to triplicate groups of 20 rainbow trout for 6 wk. As expected, diet-induced oxygen use decreased linearly (R(2) = 0.89; P digestible and metabolizable energy intakes of trout slightly increased with increasing NPDE as fat (i.e., decreasing starch content) (R(2) = 0.30, P = 0.08; and R(2) = 0.34, P = 0.05, respectively). Oxygen consumption of trout fed to satiation declined with increasing dietary NPDE as fat (R(2) = 0.48; P = 0.01). The inverse relation between digestible energy intake of trout and the diet-induced oxygen use (R(2) = 0.33; P = 0.05) suggests a possible role of diet-induced oxygen use in feed intake regulation as shown by the replacement of dietary fat by starch.

  18. Research progress of VO2 thin film as laser protecting material

    Science.gov (United States)

    Liu, Zhiwei; Lu, Yuan; Hou, Dianxin

    2018-03-01

    With the development of laser technology, the battlefield threat of directional laser weapons is becoming more and more serious. The blinding and destruction caused by laser weapons on the photoelectric equipment is an important part of the current photo-electronic warfare. The research on the defense technology of directional laser weapons based on the phase transition characteristics of VO2 thin films is an important subject. The researches of VO2 thin films are summarized based on review these points: the preparation methods of VO2 thin films, phase transition mechanism, phase transition temperature regulating, interaction between VO2 thin films and laser, and the application prospect of vo2 thin film as laser protecting material. This paper has some guiding significance for further research on the VO2 thin films in the field of defense directional laser weapons.

  19. The effect of urinary cadmium on cardiovascular fitness as measured by VO2 max in white, black and Mexican Americans

    International Nuclear Information System (INIS)

    Egwuogu, Heartley; Shendell, Derek G.; Okosun, Ike S.; Goodfellow, Lynda

    2009-01-01

    Objectives: We explored potential effects of cadmium exposure on cardiovascular fitness measures, including gender and racial/ethnic differences. Methods: Data were from the 1999 to 2000 National Health and Nutrition Examination Survey (NHANES); 1963 participating subjects were included in our analysis. Volume of oxygen consumed at sub-maximum activity (VO 2 max) were recorded in a series of graded exercises; the goal was to elicit 75% of predetermined age-specific heart rates. Cadmium from urine samples was measured in the laboratory using standard methods. Multivariate linear regression analyses were performed to determine potential relationships. Results: Increased urinary cadmium concentrations were generally associated with decreased estimated VO 2 max values. Gender and racial/ethnic differences were also observed. Specifically, associations were statistically significant for white males and Mexican American females. Conclusion: Inverse associations between urinary cadmium concentrations and estimated VO 2 max values were observed, including racial and gender differences. The implications of such gender and racial/ethnic differences on long-term cardiovascular health and health disparities of present public health concern warrant further investigation

  20. The effect of a peer on VO2 and game choice in 6-10 year old children

    Directory of Open Access Journals (Sweden)

    Lee Anne Siegmund

    2014-06-01

    Full Text Available Relative to sedentary video games (e.g., Playstation 2 (PS2, playing physically active video games (e.g., Nintendo Wii (Wii significantly increases caloric expenditure in children. Studies have demonstrated that the presence of a peer increases physical activity in children. We sought to determine if children would expend more energy and find playing Wii more motivating than PS2 when with a peer. Seventeen children (age 8.5 ± 0.4 years rested, played PS2 and Wii Sports Boxing for 10 minutes each, in two conditions: one in which the children rested/played the games alone (alone condition and another in which they played with a peer (peer condition. Oxygen consumption (VO2, and liking (visual analog scale was assessed for each 10-minute condition. After three 10-minute resting/gaming conditions, motivation was assessed using a relative reinforcing value task (RRV in which children performed computer mouse presses to gain additional access for either PS2 or Wii. VO2 was greater (p Conclusion: The presence of a peer increased VO2 during Wii play for boys but not girls. Surprisingly, the presence of a peer decreased children’s motivation to play Wii versus PS2.

  1. Anti-biofouling function of amorphous nano-Ta2O5 coating for VO2-based intelligent windows

    Science.gov (United States)

    Li, Jinhua; Guo, Geyong; Wang, Jiaxing; Zhou, Huaijuan; Shen, Hao; Yeung, Kelvin W. K.

    2017-04-01

    From environmental and health perspectives, the acquisition of a surface anti-biofouling property holds important significance for the usability of VO2 intelligent windows. Herein, we firstly deposited amorphous Ta2O5 nanoparticles on VO2 film by the magnetron sputtering method. It was found that the amorphous nano-Ta2O5 coating possessed a favorable anti-biofouling capability against Pseudomonas aeruginosa as an environmental microorganism model, behind which lay the mechanism that the amorphous nano-Ta2O5 could interrupt the microbial membrane electron transport chain and significantly elevate the intracellular reactive oxygen species (ROS) level. A plausible relationship was established between the anti-biofouling activity and physicochemical nature of amorphous Ta2O5 nanoparticles from the perspective of defect chemistry. ROS-induced oxidative damage gave rise to microbial viability loss. In addition, the amorphous nano-Ta2O5 coating can endow VO2 with favorable cytocompatibility with human skin fibroblasts. This study may provide new insights into understanding the anti-biofouling and antimicrobial actions of amorphous transition metal oxide nanoparticles, which is conducive to expanding their potential applications in environmental fields.

  2. Potassium vanadium selenite, K(VO2)3(SeO3)2

    International Nuclear Information System (INIS)

    Harrison, W.T.A.; Dussack, L.L.; Jacobson, A.J.

    1995-01-01

    The hydrothermal synthesis and single-crystal structure of potassium vanadium(V) selenite, K(VO 2 ) 3 (SeO 3 ) 2 , are reported. K(VO 2 ) 3 (SeO 3 ) 2 is a layered phase based on a hexagonal tungsten-oxide-like array of corner-sharing VO 6 octahedra capped by Se atoms, and is isostructural with NH 4 (VO 2 ) 3 (SeO 3 ) 2 . (orig.)

  3. Temperature-agile and structure-tunable optical properties of VO2/Ag thin films

    International Nuclear Information System (INIS)

    Zhang, X.R.; Hu, X.; Wang, W.; Zhao, Y.; Reinhardt, K.; Knize, R.J.; Lu, Yalin

    2012-01-01

    By integrating together VO 2 's unique near-room-temperature (RT) semiconductor-metal (S-M) phase transition with a thin silver (Ag) layer's plasmonic properties, VO 2 /Ag multilayers could present a much enhanced optical transmission change when increasing the temperature from RT to over VO 2 's S-M phase-transition temperature. Changing VO 2 and Ag layer thicknesses can also significantly tune their transmission and absorption properties, which could lead to a few useful designs in optoelectronic and energy-saving industries. (orig.)

  4. Phase coexistence in the metal-insulator transition of a VO2 thin film

    International Nuclear Information System (INIS)

    Chang, Y.J.; Koo, C.H.; Yang, J.S.; Kim, Y.S.; Kim, D.H.; Lee, J.S.; Noh, T.W.; Kim, Hyun-Tak; Chae, B.G.

    2005-01-01

    Vanadium dioxide (VO 2 ) shows a metal-insulator transition (MIT) near room temperature, accompanied by an abrupt resistivity change. Since the MIT of VO 2 is known to be a first order phase transition, it is valuable to check metallic and insulating phase segregation during the MIT process. We deposited (100)-oriented epitaxial VO 2 thin films on R-cut sapphire substrates. From the scanning tunneling spectroscopy (STS) spectra, we could distinguish metallic and insulating regions by probing the band gap. Optical spectroscopic analysis also supported the view that the MIT in VO 2 occurs through metal and insulator phase coexistence

  5. Optimization of thermochromic VO2-based structures with tunable thermal emissivity

    International Nuclear Information System (INIS)

    Li Voti, R.; Larciprete, M.C.; Leahu, G.L.; Bertolotti, M.; Sibilia, C.

    2013-01-01

    In this paper we design and simulate VO 2 /metal multilayers to obtain a large tunability of the thermal emissivity of IR filters in the typical MWIR window of many infrared cameras. The multilayer structure is optimized to realise a low-emissivity filter at high temperatures useful for military purposes. The values of tunability found for VO 2 /metal multilayers are larger than the value for a single thick layer of VO 2 . Innovative SiO 2 /VO 2 synthetic opals are also investigated to enhance the optical tunability by combining the properties of a 3D periodic structure and the specific optical properties of vanadium dioxide.

  6. Predição da potência aeróbia (VO2máx de crianças e adolescentes em teste incremental na esteira rolante Prediction of aerobic power (VO2max of children and adolescents during an incremental treadmill test

    Directory of Open Access Journals (Sweden)

    Fabiana Andrade Machado

    2013-03-01

    Full Text Available O consumo máximo de oxigênio (VO2máx é a quantidade máxima de energia que pode ser produzida pelo metabolismo aeróbio em determinada unidade de tempo, podendo ser determinado direta ou indiretamente através de equações preditivas. O objetivo deste trabalho foi elaborar uma equação preditiva específica para determinar o VO2máx de meninos de 10 a 16 anos. Quarenta e dois meninos realizaram teste ergoespirométrico de corrida em esteira rolante com velocidade inicial de 9 km/h até exaustão voluntária. Através da regressão linear múltipla foi possível desenvolver a seguinte equação para a determinação indireta do VO2máx: VO2máx (ml/min = -1574,06 + (141,38 x Vpico + (48,34 * Massa corporal, com erro padrão de estimativa = 191,5 ml/min (4,10 ml/kg/min e o coeficiente de determinação = 0,934. Sugerimos que esta é uma fórmula adequada para predizer o VO2máx para esta população.The maximal oxygen uptake (VO2max is the maximal quantity of energy that can be produced by the aerobic metabolism in certain time unity. It can be determined direct or indirectly by predictive equations. The objective of this study was to make a specific predictive equation to determine the VO2max from boys aged 10-16 years-old. Forty-two boys underwent a treadmill running ergospirometric test, with the initial velocity set at 9 km/h, until voluntary exhaustion. By the multiple linear regression was possible to develop the following equation for the indirect determination of the VO2max: VO2max (ml/min = -1574.06 + (141.38 x Vpeak + (48.34 * Body mass, with standard error of estimate = 191.5 ml/min (4.10 ml/kg/min and coefficient of determination = 0.934. We suggest that this formula is appropriate to predict VO2max for this population.

  7. Estimativa das contribuições dos sistemas anaeróbio lático e alático durante exercícios de cargas constantes em intensidades abaixo do VO2max Estimation of contributions of the anaerobic lactic and alactic systems during constant-load exercises at intensities below the VO2max

    Directory of Open Access Journals (Sweden)

    Marcos David Silva-Cavalcante

    2013-01-01

    Full Text Available O objetivo do estudo foi estimar as contribuições do metabolismo anaeróbio lático (MAL e alático (MAA em intensidades abaixo do consumo máximo de oxigênio (VO2max. Dez homens (23 ± 4 anos, 176,4 ± 6,8 cm, 72,4 ± 8,2 kg, 12,0 ± 4,5 % de gordura corporal realizaram um teste progressivo até a exaustão voluntária para identificação do VO2max, da potência correspondente ao VO2max (WVO2max e do segundo limiar ventilatório (LV2. Na segunda e na terceira visita foram realizados seis testes de cargas constantes (três testes por sessão com intensidades abaixo do VO2max. Houve uma predominância do MAL sobre o MAA durante os exercícios submáximos a partir da intensidade correspondente ao LV2, sendo significativamente maior em 90% VO2max (p The purpose this study was that estimated contributions of the anaerobic lactic (MAL and alactic (MAA metabolism during constant load exercises at intensities below the maximal oxygen capacity uptake (VO2max. Ten males (23 ± 4 years, 176.4 ± 6.8 cm, 72.4 ± 8.2 kg, 12.0 ± 4.5 % of fat body performed in the first visit a progressive test until exhaustion to identification of VO2max, power output corresponding to the VO2max (WVO2max and second ventilatory threshold (LV2. On the second and third visit, the participants performed six constant workload tests (3 per session with intensities below VO2max. There was a predominance of MAL about MAA during the exercises sub-maximal from intensity corresponding to the LV2, being significantly higher at 90% VO2max (p < 0.05. Thus, these results may help coaches to implement training loads appropriate to their athletes, according to the metabolic demand of the competition.

  8. Oxygen Consumption Constrains Food Intake in Fish Fed Diets Varying in Essential Amino Acid Composition

    NARCIS (Netherlands)

    Subramanian, S.; Geurden, I.; Figueiredo-Silva, A.C.; Nusantoro, S.; Kaushik, S.J.; Verreth, J.A.J.; Schrama, J.W.

    2013-01-01

    Compromisation of food intake when confronted with diets deficient in essential amino acids is a common response of fish and other animals, but the underlying physiological factors are poorly understood. We hypothesize that oxygen consumption of fish is a possible physiological factor constraining

  9. Using carbon emissions, oxygen consumption, and retained energy to calculate dietary ME intake by beef steers

    Science.gov (United States)

    Eight cross-bred beef steers (initial BW = 241 ± 4.10 kg) were used in a 77-d feeding experiment to determine if ME intake can be determined from carbon emissions, oxygen consumption, and energy retention estimates. Steers were housed in a pen equipped with individual feed bunks and animal access w...

  10. Synthesis of sub-10 nm VO2 nanoparticles films with plasma-treated glass slides by aqueous sol–gel method

    International Nuclear Information System (INIS)

    Lan, Shi-Di; Cheng, Chih-Chia; Huang, Chi-Hsien; Chen, Jem-Kun

    2015-01-01

    Highlights: • Sub-10 nm VO 2 nanoparticles (VNPs) are synthesized on a plasma-treated glass. • Glass slides generate negative charges sites after plasma treatment to attract VO 2 + . • Doping tungsten with 1 wt% in VNPs did not change particle size significantly. • The particle size of VNP can be tuned by the density of negative charge sites. • Sub-10 nm structured VO 2 particle films exhibited high visible transmittance. - Abstract: This paper describes an aqueous sol–gel synthesis of thermochromic thin films consisted of vanadium dioxide nanoparticles (VNPs) on glass slides. The glass slides were treated by argon/oxygen plasma to generate dispersedly negative charge sites on the surface to attract VO 2 + from a sol–gel solution. After heat treatment in a low-pressure carbon monoxide/carbon dioxide (CO/CO 2 ) atmosphere, the VNPs could be generated in sub-10 nm of particle size on the surface. Various levels of doping were achieved by adding small quantities of a water-soluble tungsten compound to the sol; however, the particle size increased slightly with the tungsten doping levels. The change in electrical conductivity with temperature for VNP films were measured and compared to VO 2 crystalline films. VNP films exhibited the lower transition temperature of the semiconductor to metal phase change; at a doping level of 4 wt% the transition temperature was measured at 32.2 ± 1.2 and 24.1 ± 1.2 °C for the VO 2 and VNP films, respectively. The VNP films showed excellent visible transparency and a large change in transmittance at near-infrared (NIR) wavelengths before and after the metal–insulator phase transition (MIT). The current method is a landmark in the development of nanostructured material toward applications in energy-saving smart windows.

  11. Epitaxial growth of higher transition-temperature VO2 films on AlN/Si

    Directory of Open Access Journals (Sweden)

    Tetiana Slusar

    2016-02-01

    Full Text Available We report the epitaxial growth and the mechanism of a higher temperature insulator-to-metal-transition (IMT of vanadium dioxide (VO2 thin films synthesized on aluminum nitride (AlN/Si (111 substrates by a pulsed-laser-deposition method; the IMT temperature is TIMT ≈ 350 K. X-ray diffractometer and high resolution transmission electron microscope data show that the epitaxial relationship of VO2 and AlN is VO2 (010 ‖ AlN (0001 with VO2 [101] ‖   AlN   [ 2 1 ̄ 1 ̄ 0 ] zone axes, which results in a substrate-induced tensile strain along the in-plane a and c axes of the insulating monoclinic VO2. This strain stabilizes the insulating phase of VO2 and raises TIMT for 10 K higher than TIMT single crystal ≈ 340 K in a bulk VO2 single crystal. Near TIMT, a resistance change of about four orders is observed in a thick film of ∼130 nm. The VO2/AlN/Si heterostructures are promising for the development of integrated IMT-Si technology, including thermal switchers, transistors, and other applications.

  12. Body fat, abdominal fat and body fat distribution related to VO(2PEAK) in young children

    DEFF Research Database (Denmark)

    Dencker, Magnus; Wollmer, Per; Karlsson, Magnus K

    2011-01-01

    as a percentage of body mass (BF%) and body fat distribution as AFM/TBF. VO(2PEAK) was assessed by indirect calorimetry during maximal exercise test. Results. Significant relationships existed between body fat measurements and VO(2PEAK) in both boys and girls, with Pearson correlation coefficients for absolute...

  13. VO2 /TiN Plasmonic Thermochromic Smart Coatings for Room-Temperature Applications.

    Science.gov (United States)

    Hao, Qi; Li, Wan; Xu, Huiyan; Wang, Jiawei; Yin, Yin; Wang, Huaiyu; Ma, Libo; Ma, Fei; Jiang, Xuchuan; Schmidt, Oliver G; Chu, Paul K

    2018-03-01

    Vanadium dioxide/titanium nitride (VO 2 /TiN) smart coatings are prepared by hybridizing thermochromic VO 2 with plasmonic TiN nanoparticles. The VO 2 /TiN coatings can control infrared (IR) radiation dynamically in accordance with the ambient temperature and illumination intensity. It blocks IR light under strong illumination at 28 °C but is IR transparent under weak irradiation conditions or at a low temperature of 20 °C. The VO 2 /TiN coatings exhibit a good integral visible transmittance of up to 51% and excellent IR switching efficiency of 48% at 2000 nm. These unique advantages make VO 2 /TiN promising as smart energy-saving windows. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Componente lento do VO2 em crianças durante exercício pesado de corrida: análise com base em diferentes modelos matemáticos Componente lento de VO2 en niños durante ejercicio arduo de carrera: análisis con base en diferentes modelos matemáticos Slow component of VO2 in children during running exercise performed at heavy intensity domain: analysis with different mathematical models

    Directory of Open Access Journals (Sweden)

    Fabiana Andrade Machado

    2006-12-01

    . Participaron del estudio 8 niños del sexo masculino (11,92 ± 0,63 años; 44,06 ± 13,01 kg; 146,63 ± 7,25 cm; y niveles de madurez sexual 1 y 2, aparentemente saludables, no entrenados, que realizaron en diferentes días: 1 Test incremental en la cinta rodante para determinar el consumo de oxígeno de pico (VO2pico y del límite de lactato (LL; y 2 Dos tests de carga constante en cinta rodante durante seis minutos a intensidad de 75%delta [75%delta = LL + 0,75 x (VO2pico - LL]. Para determinar el CL usamos: a modelo matemático de tres términos (Exp3; y b la diferencia en el VO2 entre el sexto y el tercer minuto de ejercicio (deltaVO2 6-3 min. El CL fue expresado en valores absolutos (ml/min y también como contribución porcentual de CL para el aumento de VO2 al final del ejercicio (%CL. El CL determinado por el modelo Exp3 (129,69 ± 75,71 ml/min y 8,4 ± 2,92% fue significativamente mayor al que fue obtenido por el modelo deltaVO2 6-3 min (68,69 ± 102,54 ml/min y 3,6 ± 7,34%. Por tanto, los valores de CL obtenidos en niños durante el ejercicio de carrera realizado en dominio pesado (75%delta son dependientes del modelo de análisis (Exp3 x deltaVO2 6-3 min.The purpose of this study was to identify and quantify the magnitude of the slow component of VO2 (SC in children during running exercise, performed at heavy intensity domain (75%delta, using two different mathematical models: a three-exponential model and; b deltaVO2 6-3 min. Eight healthy male children (11.92 ± 0.63 years; 44.06 ± 13.01 kg; 146.63 ± 7.25 cm; and sexual maturity levels 1 and 2, not trained, performed in different days the following tests: 1 incremental running treadmill test to determine the peak oxygen uptake (VO2peak and the lactate threshold (LT; and 2 two transitions from baseline to 75%delta [75%D = LT + 0.75 x (VO2 peak - LT] for six minutes on treadmill. The SC was deter mined by two models: a three-exponential model (Exp3; and b the VO2 difference between the sixth and the third

  15. Graphene/VO2 hybrid material for high performance electrochemical capacitor

    International Nuclear Information System (INIS)

    Deng, Lingjuan; Zhang, Gaini; Kang, Liping; Lei, Zhibin; Liu, Chunling; Liu, Zong-Huai

    2013-01-01

    Graphical abstract: Graphene/VO 2 hybrid materials are prepared by one-step simultaneous hydrothermal reduction technology. The prepared graphene (1.0)/VO 2 hybrid material shows a specific capacitances of 225 F g −1 in 0.5 mol L −1 K 2 SO 4 solution. Furthermore, an asymmetric electrochemical capacitor with graphene (1.0)/VO 2 as a positive electrode and graphene as a negative electrode is assembled, and it can work in a cell voltage of 1.7 V and show excellent capacitive property. - Highlights: • Graphene/VO 2 hybrid material has been prepared by one-step hydrothermal reduction. • Graphene/VO 2 hybrid material exhibits high specific capacitance. • An asymmetric capacitor working at 1.7 V in aqueous solution is assembled based on graphene/VO 2 electrode. • The asymmetric capacitor exhibits high energy density. - Abstract: Vanadium oxides have attracted significant attention for electrochemical capacitor because of their extensive multifunctional properties. In the present work, graphene/VO 2 (RG/VO 2 ) hybrid materials with different RG amounts are prepared in a mixture of ammonium vanadate, formic acid and graphite oxide (GO) nanosheets by one-step simultaneous hydrothermal reduction technology. The hydrothermal treatment makes the reduction of GO into RG and the formation of VO 2 particles with starfruit morphology. The starfruit-like VO 2 particles are uniformly embedded in the hole constructed by RG nanosheets, which makes the electrode–electrolyte contact better. A high specific capacitance of 225 F g −1 has been achieved for RG(1.0)/VO 2 electrode with RG content of 26 wt% in 0.5 mol L −1 K 2 SO 4 electrolyte. An asymmetrical electrochemical capacitor is assembled by using RG(1.0)/VO 2 as positive electrode and RG as negative electrode, and it can be reversibly charged–discharged at a cell voltage of 1.7 V in 0.5 mol L −1 K 2 SO 4 electrolyte. The asymmetrical capacitor can deliver an energy density of 22.8 Wh kg −1 at a power density

  16. The effect of a peer on VO2 and game choice in 6–10 year old children

    Science.gov (United States)

    Siegmund, Lee A.; Naylor, Jonathan B.; Santo, Antonio S.; Barkley, Jacob E.

    2014-01-01

    Relative to sedentary video games (e.g., Playstation 2®), playing physically active video games (e.g., Nintendo Wii Sports Boxing®) significantly increases caloric expenditure in children. Studies have demonstrated that the presence of a peer increases physical activity in children. We sought to determine if children would expend more energy and find playing the “exergame” (Wii) more motivating than the sedentary video game (Playstation 2) when with a peer. Seventeen children (age 8.5 ± 0.4 years) rested, played the sedentary video game and “exergame” for 10 min each, in two conditions: one in which the children rested/played the games alone (alone condition) and another in which they played with a peer (peer condition). Oxygen consumption (VO2), and liking (visual analog scale) was assessed for each 10-min condition. After three 10-min resting/gaming conditions, motivation was assessed using a relative reinforcing value task in which children performed computer mouse presses to gain additional access for either the sedentary video game or “exergame.” VO2 was greater (p 4.1 ml·kg−1·min−1) vs. rest (mean = 5.14 ± 1.46 ml·kg−1·min−1) and the sedentary video game (mean = 5.83 ± 2.1 ml·kg−1·min−1). During the peer condition, there were no significant differences (p > 0.05) in VO2 relative to the alone condition. In an exploratory analysis boys exhibited a greater (p = 0.02) increase in VO2 from rest to “exergame” (Δ 9.0 ± 3.7 ml·kg−1·min−1), relative to girls (Δ 4.9 ± 2.9 ml·kg−1·min−1). Boys showed a significantly greater increase (p = 0.05) in VO2 from the resting condition to “exergame” in the presence of a peer (Δ 11.1 ± 5.3 ml·kg−1·min−1) vs. the alone condition (Δ 6.8 ± 3.1 ml·kg−1 ·min−1). Liking was significantly (p 4.0 ± 2.8 cm). Motivation for “exergame” significantly decreased (p = 0.03) from alone (340.8 ± 106.8 presses) to the peer condition (147.8 ± 81.6 presses). Conclusion

  17. The effect of a peer on VO2 and game choice in 6-10 year old children.

    Science.gov (United States)

    Siegmund, Lee A; Naylor, Jonathan B; Santo, Antonio S; Barkley, Jacob E

    2014-01-01

    Relative to sedentary video games (e.g., Playstation 2®), playing physically active video games (e.g., Nintendo Wii Sports Boxing®) significantly increases caloric expenditure in children. Studies have demonstrated that the presence of a peer increases physical activity in children. We sought to determine if children would expend more energy and find playing the "exergame" (Wii) more motivating than the sedentary video game (Playstation 2) when with a peer. Seventeen children (age 8.5 ± 0.4 years) rested, played the sedentary video game and "exergame" for 10 min each, in two conditions: one in which the children rested/played the games alone (alone condition) and another in which they played with a peer (peer condition). Oxygen consumption (VO2), and liking (visual analog scale) was assessed for each 10-min condition. After three 10-min resting/gaming conditions, motivation was assessed using a relative reinforcing value task in which children performed computer mouse presses to gain additional access for either the sedentary video game or "exergame." VO2 was greater (p 4.1 ml·kg(-1)·min(-1)) vs. rest (mean = 5.14 ± 1.46 ml·kg(-1)·min(-1)) and the sedentary video game (mean = 5.83 ± 2.1 ml·kg(-1)·min(-1)). During the peer condition, there were no significant differences (p > 0.05) in VO2 relative to the alone condition. In an exploratory analysis boys exhibited a greater (p = 0.02) increase in VO2 from rest to "exergame" (Δ 9.0 ± 3.7 ml·kg(-1)·min(-1)), relative to girls (Δ 4.9 ± 2.9 ml·kg(-1)·min(-1)). Boys showed a significantly greater increase (p = 0.05) in VO2 from the resting condition to "exergame" in the presence of a peer (Δ 11.1 ± 5.3 ml·kg(-1)·min(-1)) vs. the alone condition (Δ 6.8 ± 3.1 ml·kg(-1) ·min(-1)). Liking was significantly (p 4.0 ± 2.8 cm). Motivation for "exergame" significantly decreased (p = 0.03) from alone (340.8 ± 106.8 presses) to the peer condition (147.8 ± 81.6 presses). VO2 was greater during "exergame

  18. The influence of VO2(B nanobelts on thermal decomposition of ammonium perchlorate

    Directory of Open Access Journals (Sweden)

    Zhang Yifu

    2015-09-01

    Full Text Available The influence of vanadium dioxide VO2(B on thermal decomposition of ammonium perchlorate (AP has not been reported before. In this contribution, the effect of VO2(B nanobelts on the thermal decomposition of AP was investigated by the Thermo- Gravimetric Analysis and Differential Thermal Analysis (TG/DTA. VO2(B nanobelts were hydrothermally prepared using peroxovanadium (V complexes, ethanol and water as starting materials. The thermal decomposition temperatures of AP in the presence of I wt.%, 3 wt.% and 6 wt.% of as-obtained VO2VO2(B nanobelts had a great influence on the thermal decomposition temperature of AP Furthermore, the influence of the corresponding V2Os, which was obtained by thermal treatment of VO2(B nanobelts, on the thermal decomposition of AP was also investigated. The resufs showed that VO2(B nanobelts had a greater influence on the thermal decomposition temperature of AP than that of V2Os.

  19. Compare the phase transition properties of VO2 films from infrared to terahertz range

    Science.gov (United States)

    Liang, Shan; Shi, Qiwu; Huang, Wanxia; Peng, Bo; Mao, Zhenya; Zhu, Hongfu

    2018-06-01

    VO2 with reversible semiconductor-metal phase transition properties is particularly available for the application in smart opto-electrical devices. However, there are rare reports on comparing its phase transition properties at different ranges. In this study, the VO2 films are designed with the similar crystalline structure and stoichiometry, but different morphologies by inorganic and organic sol-gel methods, and their phase transition characteristics are compared both at infrared and terahertz range. The results indicate that the VO2 film prepared by inorganic sol-gel method shows more compact nanostructure. It results in larger resistivity change, infrared and terahertz switching ratio in the VO2 film. Moreover, it presents that the phase transition intensity of VO2 film in terahertz range is more sensitive to its microstructure. This work is helpful for understanding the susceptibility of terahertz switching properties of VO2 to its microstructure. And it can provide insights for the applications of VO2 in terahertz smart devices.

  20. Validation of a ramp running protocol for determination of the true VO2max in mice

    Directory of Open Access Journals (Sweden)

    Mohamed Ayachi

    2016-08-01

    Full Text Available In the field of comparative physiology, it remains to be established whether the concept of VO2max is valid in the mouse and, if so, how this value can be accurately determined. In humans, VO2max is generally considered to correspond to the plateau observed when VO2 no longer rises with an increase in workload. In contrast, the concept of VO2peak tends to be used in murine studies. The objectives of the present study were to determine whether (i a continuous ramp protocol yielded a higher VO2peak than a stepwise, incremental protocol, and (ii the VO2peak measured in the ramp protocol corresponded to VO2max. The three protocols (based on intensity-controlled treadmill running until exhaustion with eight female FVB/N mice were performed in random order: (a an incremental protocol that begins at 10 m.min-1 speed and increases by 3 m.min-1 every 3 min. (b a ramp protocol with slow acceleration (3 m.min-2, and (c a ramp protocol with fast acceleration (12 m.min-2. Each protocol was performed with two slopes (0° and 25°. Hence, each mouse performed six exercise tests. We found that the value of VO2peak was protocol-dependent (p 8 mmol.l-1 and a respiratory exchange ratio >1. The total duration of the 3 m.min-2 0° ramp protocol was shorter than that of the incremental protocol. Taken as a whole, our results suggest that VO2max in the mouse is best determined by applying a ramp exercise protocol with slow acceleration and no treadmill slope.

  1. Efek minuman kombinasi maltodekstrin dan vitamin C terhadap VO2maks atlet sepak bola

    Directory of Open Access Journals (Sweden)

    Desty Ervira Puspaningtyas

    2015-07-01

    Full Text Available Background: VO2max is one of win determiner in a game. Athletes receive training to improve technical skills, tactical skills, and physiology functions that can support the improvement of VO2max, so they can improve their achievement. Maltodextrin and vitamin C can be used as an ingredient for beverage products which can improve VO2max. Objective: To assess the effect of maltodextrin and vitamin C combination drink on VO2max in soccer athletes. Method: Type of this study was experimental design with the same subject design. The study was conducted from January 2014 until June 2014 at Culinary Laboratory Universitas Gadjah Mada (UGM and Stadium of Universitas Negeri Yogyakarta (UNY. Subjects of this study were 14 soccer players coming from Universitas Negeri Yogyakarta (UNY. Every subject had to fulfill the inclusion and exclusion criteria, and the subjects were chosen by purposive sampling. In the first treatment, subjects received the combination drink―a drink with a composition 15% of maltodextrin and 250 mg of vitamin C in 300 mL. After 6 days washout period, subjects received 300 mL plain water. Drinks were given 30 minutes before VO2max test. VO2max test method used in this study was yo-yo intermittent recovery test level 2 (IR-2. Results: VO2max when subjects consumed maltodextrin and vitamin C combination drink was significantly lower than VO2max when athletes consumed plain water (p=0,0000. Conclusion: Maltodextrin and vitamin C combination drink was less effective than plain water to enhance VO2max.

  2. VV and VO2 defects in silicon studied with hybrid density functional theory

    KAUST Repository

    Christopoulos, Stavros Richard G

    2014-12-07

    The formation of VO (A-center), VV and VO2 defects in irradiated Czochralski-grown silicon (Si) is of technological importance. Recent theoretical studies have examined the formation and charge states of the A-center in detail. Here we use density functional theory employing hybrid functionals to analyze the formation of VV and VO2 defects. The formation energy as a function of the Fermi energy is calculated for all possible charge states. For the VV and VO2 defects double negatively charged and neutral states dominate, respectively.

  3. Thin-film VO2 submillimeter-wave modulators and polarizers

    International Nuclear Information System (INIS)

    Fan, J.C.C.; Fetterman, H.R.; Bachner, F.J.; Zavracky, P.M.; Parker, C.D.

    1977-01-01

    Submillimeter-wave modulators and switchable polarizers have been fabricated from VO 2 thin films deposited on sapphire substrates. By passing electric current pulses through elements made from these films, the films can be thermally cycled through the insulator-to-metal transition that occurs in VO 2 at about 65 degreeC. In the insulating state, the films are found to have negligible effect on the transmission at submillimeter wavelengths, while above the phase transition the transmission is strongly reduced by the free-electron effects characteristic of a metal. Other possible applications of such switchable VO 2 elements include variable bandpass filters and diffraction grating beam-steering devices

  4. Effects of oxygen delivery, dietary nitrate, intensified training and prior exercise on oxygen uptake kinetics and performance in humans

    DEFF Research Database (Denmark)

    Christensen, Peter Møller

    benefits from supplementing with nitrate to improve exercise efficiency and performance in endurance trained subjects. Furthermore it appears difficult to improve VO2 kinetics with intensified training in trained athletes; however intense exercise can amplify the VO2 response during subsequent high......In response to an increase in the metabolic demand the oxygen uptake (VO2) increases in an exponential fashion in exercising muscles and stabilizes after 1-2 min eventually reaching a plateau or steady state where the energy demand is matched by the l vel of VO2. VO2 kinetics describes the distinct...... phases of the VO2 response at the onset of exercise. Fast VO2 kinetics are considered to be beneficial in intense endurance sports with competitions lasting ~2-8 min, whereas low VO2 at steady state (high efficiency) is considered beneficial especially in events of longer duration. To improve...

  5. Predicted VO2max and effectiveness of external chest compression by Chinese nurses.

    Science.gov (United States)

    Ho, Leo S T; Jones, Alice Y M; Rainer, Timothy H

    2017-08-01

    The aims of this study were to assess the influence of sex and body position on external chest compression (ECC) to a manikin by Chinese nurses and to determine the relationship between rescuer's predicted VO2max and ECC depth. A total of 40 nurses performed ECC on a manikin for 5 min in the standing (S) and bed-mount kneeling (K) position, then completed a Chester step-test, in 3 separate days. The rate and depth of compressions and oxygen consumption during ECC were measured. Mean compression rate recorded was above 100/min in both positions throughout ECC. Mean compression depth for male participants was more than 38 mm for 5 min in the K-position but only 3 min in the S-position. Female participants achieved this compression depth for less than 90 s in the K-position but not at all in the S-position. Irrespective of sex, the K-position appears to facilitate effective ECC. The relationship between aerobic fitness of female nurses and their ability to perform effective cardiopulmonary resuscitation warrants further investigation.

  6. High performance of solvothermally prepared VO2(B as anode for aqueous rechargeable lithium batteries

    Directory of Open Access Journals (Sweden)

    Milošević Sanja

    2015-01-01

    Full Text Available The VO2 (B was synthesized via a simple solvothermal route at 160oC in ethanol. The initial discharge capacity of VO2 (B anode, in saturated aqueous solution of LiNO3, was 177 mAh g-1 at a current rate of 50 mA g-1. After 50 cycles capacity fade was 4%, but from 20th-50th cycle no capacity drop was observed. The VO2 (B has shown very good cyclability at current rate of even 1000 mA g-1 with initial discharge capacity of 92 mAh g-1. The excellent electrochemical performance of VO2 (B was attributed to the stability of micro-nano structures to repeated intercalation /deintercalation process, very good electronic conductivity as well as the very low charge transfer resistance in the aqueous electrolyte. [Projekat Ministarstva nauke Republike Srbije, br. III45014

  7. Selective scanning tunneling microscope light emission from rutile phase of VO2.

    Science.gov (United States)

    Sakai, Joe; Kuwahara, Masashi; Hotsuki, Masaki; Katano, Satoshi; Uehara, Yoichi

    2016-09-28

    We observed scanning tunneling microscope light emission (STM-LE) induced by a tunneling current at the gap between an Ag tip and a VO2 thin film, in parallel to scanning tunneling spectroscopy (STS) profiles. The 34 nm thick VO2 film grown on a rutile TiO2 (0 0 1) substrate consisted of both rutile (R)- and monoclinic (M)-structure phases of a few 10 nm-sized domains at room temperature. We found that STM-LE with a certain photon energy of 2.0 eV occurs selectively from R-phase domains of VO2, while no STM-LE was observed from M-phase. The mechanism of STM-LE from R-phase VO2 was determined to be an interband transition process rather than inverse photoemission or inelastic tunneling processes.

  8. Predictors of VO2Peak in children age 6- to 7-years-old

    DEFF Research Database (Denmark)

    Dencker, Magnus; Hermansen, Bianca; Bugge, Anna

    2011-01-01

    This study investigated the predictors of aerobic fitness (VO2PEAK) in young children on a population-base. Participants were 436 children (229 boys and 207 girls) aged 6.7 ± 0.4 yrs. VO2PEAK was measured during a maximal treadmill exercise test. Physical activity was assessed by accelerometers....... Total body fat and total fat free mass were estimated from skinfold measurements. Regression analyses indicated that significant predictors for VO2PEAK per kilogram body mass were total body fat, maximal heart rate, sex, and age. Physical activity explained an additional 4-7%. Further analyses showed...... the main contributing factors for absolute values of VO2PEAK were fat free mass, maximal heart rate, sex, and age. Physical activity explained an additional 3-6%....

  9. VO2 nanoparticles on edge orientated graphene foam for high rate lithium ion batteries and supercapacitors

    Science.gov (United States)

    Ren, Guofeng; Zhang, Ruibo; Fan, Zhaoyang

    2018-05-01

    With the fully exposed graphene edges, high conductivity and large surface area, edge oriented graphene foam (EOGF), prepared by deposition of perpendicular graphene network encircling the struts of Ni foam, is a superior scaffold to support active materials for electrochemical applications. With VO2 as an example, EOGF loaded VO2 nanoparticle (VO2/EOGF) electrode has high rate performance as cathode in lithium ion batteries (LIBs). In addition to the Li+ intercalation into the lattice, contribution of non-diffusion-limited pseudocapacitance to the capacity is prominent at high rates. VO2/EOGF based supercapacitor also exhibits fast response, with a characteristic frequency of 15 Hz when the phase angle reaches -45°, or a relaxation time constant of 66.7 ms. These results suggest the promising potential of EOGF as a scaffold in supporting active nanomaterials for electrochemical energy storage and other applications.

  10. Epitaxial growth and electronic structure of oxyhydride SrVO2H thin films

    Science.gov (United States)

    Katayama, Tsukasa; Chikamatsu, Akira; Yamada, Keisuke; Shigematsu, Kei; Onozuka, Tomoya; Minohara, Makoto; Kumigashira, Hiroshi; Ikenaga, Eiji; Hasegawa, Tetsuya

    2016-08-01

    Oxyhydride SrVO2H epitaxial thin films were fabricated on SrTiO3 substrates via topotactic hydridation of oxide SrVO3 films using CaH2. Structural and composition analyses suggested that the SrVO2H film possessed one-dimensionally ordered V-H--V bonds along the out-of-plane direction. The synthesis temperature could be lowered by reducing the film thickness, and the SrVO2H film was reversible to SrVO3 by oxidation through annealing in air. Photoemission and X-ray absorption spectroscopy measurements revealed the V3+ valence state in the SrVO2H film, indicating that the hydrogen existed as hydride. Furthermore, the electronic density of states was highly suppressed at the Fermi energy, consistent with the prediction that tetragonal distortion induces metal to insulation transition.

  11. Supercritical temperature synthesis of fluorine-doped VO2(M) nanoparticle with improved thermochromic property

    Science.gov (United States)

    Riapanitra, Anung; Asakura, Yusuke; Cao, Wenbin; Noda, Yasuto; Yin, Shu

    2018-06-01

    Fluorine-doped VO2(M) nanoparticles have been successfully synthesized using the hydrothermal method at a supercritical temperature of 490 °C. The pristine VO2(M) has the critical phase transformation temperature of 64 °C. The morphology and homogeneity of the monoclinic structure VO2(M) were adopted by the fluorine-doped system. The obtained particle size of the samples is smaller at the higher concentration of anion doping. The best reduction of critical temperature was achieved by fluorine doping of 0.13% up to 48 °C. The thin films of the fluorine-doped VO2(M) showed pronounced thermochromic property and therefore are suitable for smart window applications.

  12. Thermally tunable VO2-SiO2 nanocomposite thin-film capacitors

    Science.gov (United States)

    Sun, Yifei; Narayanachari, K. V. L. V.; Wan, Chenghao; Sun, Xing; Wang, Haiyan; Cooley, Kayla A.; Mohney, Suzanne E.; White, Doug; Duwel, Amy; Kats, Mikhail A.; Ramanathan, Shriram

    2018-03-01

    We present a study of co-sputtered VO2-SiO2 nanocomposite dielectric thin-film media possessing continuous temperature tunability of the dielectric constant. The smooth thermal tunability is a result of the insulator-metal transition in the VO2 inclusions dispersed within an insulating matrix. We present a detailed comparison of the dielectric characteristics of this nanocomposite with those of a VO2 control layer and of VO2/SiO2 laminate multilayers of comparable overall thickness. We demonstrated a nanocomposite capacitor that has a thermal capacitance tunability of ˜60% between 25 °C and 100 °C at 1 MHz, with low leakage current. Such thermally tunable capacitors could find potential use in applications such as sensing, thermal cloaks, and phase-change energy storage devices.

  13. EVALUATION AND DEVELOPMENT OF THE VO2 OF ATHLETES THAT ATTEND A SOCCER SCHOOL

    Directory of Open Access Journals (Sweden)

    Felipe Bittencourt Oliveira

    2012-11-01

    Full Text Available The goal of this study was to identify the effects from technical and physical activities on the VO2, of male athletes aged 14 to 15, participants of a soccer school, in the municipality of Rio Pardo - RS. The semi-experimental research involved 10 male adolescents. For the VO2 evaluation the 12 minute Cooper test was used. Interval-training work was applied, at which the athletes exercised 75% of their maximum speed, in 60-meter runs. After training for two months (at least two sessions a week the Cooper post-test was applied to check the improvement of the VO2. As results of this study, we can draw the conclusion that all adolescents involved in this training showed considerable improvement in their maximum VO2, especially the 15-year-old teens, who managed to obtain a much higher percentage level.

  14. Preexercise metabolic alkalosis induced via bicarbonate ingestion accelerates Vo2 kinetics at the onset of a high-power-output exercise in humans.

    Science.gov (United States)

    Zoladz, Jerzy A; Szkutnik, Zbigniew; Duda, Krzysztof; Majerczak, Joanna; Korzeniewski, Bernard

    2005-03-01

    The present study investigated the effect of preexercise metabolic alkalosis on the primary component of oxygen uptake (Vo(2)) kinetics, characterized by tau(1). Seven healthy physically active nonsmoking men, aged 22.4 +/- 1.8 (mean +/- SD) yr, maximum Vo(2) (Vo(2 max)) 50.4 +/- 4 ml.min(-1).kg(-1), performed two bouts of cycling, corresponding to 40 and 87% of Vo(2 max), lasting 6 min each, separated by a 20-min pause, once as a control study and a few days later at approximately 90 min after ingestion of 3 mmol/kg body wt of NaHCO(3). Blood samples for measurements of bicarbonate concentration and hydrogen ion concentration were taken from antecubital vein via catheter. Pulmonary Vo(2) was measured continuously breath by breath. The values of tau(1) were calculated by using six various approaches published in the literature. Preexercise level of bicarbonate concentration after ingestion of NaHCO(3) was significantly elevated (P < 0.01) compared with the control study (28.96 +/- 2.11 vs. 24.84 +/- 1.18 mmol/l; P < 0.01), and [H(+)] was significantly (P < 0.01) reduced (42.79 +/- 3.38 nmol/l vs. 46.44 +/- 3.51 nmol/l). This shift (P < 0.01) was also present during both bouts of exercise. During cycling at 40% of Vo(2 max), no significant effect of the preexercise alkalosis on the magnitude of tau(1) was found. However, during cycling at 87% of Vo(2 max), the tau(1) calculated by all six approaches was significantly (P < 0.05) reduced, compared with the control study. The tau(1) calculated as in Borrani et al. (Borrani F, Candau R, Millet GY, Perrey S, Fuchsloscher J, and Rouillon JD. J Appl Physiol 90: 2212-2220, 2001) was reduced on average by 7.9 +/- 2.6 s, which was significantly different from zero with both the Student's t-test (P = 0.011) and the Wilcoxon's signed-ranks test (P = 0.014).

  15. Broadband terahertz generation using the semiconductor-metal transition in VO2

    Directory of Open Access Journals (Sweden)

    Nicholas A. Charipar

    2016-01-01

    Full Text Available We report the design, fabrication, and characterization of broadband terahertz emitters based on the semiconductor-metal transition in thin film VO2 (vanadium dioxide. With the appropriate geometry, picosecond electrical pulses are generated by illuminating 120 nm thick VO2 with 280 fs pulses from a femtosecond laser. These ultrafast electrical pulses are used to drive a simple dipole antenna, generating broadband terahertz radiation.

  16. Size and composition-controlled fabrication of VO2 nanocrystals by terminated cluster growth

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Andre; Slack, Jonathan

    2013-05-14

    A physical vapor deposition-based route for the fabrication of VO2 nanoparticles is demonstrated, consisting of reactive sputtering and vapor condensation at elevated pressures. The oxidation of vanadium atoms is an efficient heterogeneous nucleation method, leading to high nanoparticle throughtput. Fine control of the nanoparticle size and composition is obtained. Post growth annealing leads to crystalline VO2 nanoparticles with optimum thermocromic and plasmonic properties.

  17. VO2 OFF TRANSIENT KINETICS IN EXTREME INTENSITY SWIMMING

    Directory of Open Access Journals (Sweden)

    Ana Sousa

    2011-09-01

    Full Text Available Inconsistencies about dynamic asymmetry between the on- and off- transient responses in oxygen uptake are found in the literature. Therefore, the purpose of this study was to characterize the oxygen uptake off-transient kinetics during a maximal 200-m front crawl effort, as examining the degree to which the on/off regularity of the oxygen uptake kinetics response was preserved. Eight high level male swimmers performed a 200-m front crawl at maximal speed during which oxygen uptake was directly measured through breath-by-breath oxymetry (averaged every 5 s. This apparatus was connected to the swimmer by a low hydrodynamic resistance respiratory snorkel and valve system. Results: The on- and off-transient phases were symmetrical in shape (mirror image once they were adequately fitted by a single-exponential regression models, and no slow component for the oxygen uptake response was developed. Mean (± SD peak oxygen uptake was 69.0 (± 6.3 mL·kg-1·min-1, significantly correlated with time constant of the off- transient period (r = 0.76, p < 0.05 but not with any of the other oxygen off-transient kinetic parameters studied. A direct relationship between time constant of the off-transient period and mean swimming speed of the 200-m (r = 0.77, p < 0.05, and with the amplitude of the fast component of the effort period (r = 0.72, p < 0.05 were observed. The mean amplitude and time constant of the off-transient period values were significantly greater than the respective on- transient. In conclusion, although an asymmetry between the on- and off kinetic parameters was verified, both the 200-m effort and the respectively recovery period were better characterized by a single exponential regression model

  18. [Ambient air interference in oxygen intake measurements in liquid incubating media with the use of open polarographic cells].

    Science.gov (United States)

    Miniaev, M V; Voronchikhina, L I

    2007-01-01

    A model of oxygen intake by aerobic bio-objects in liquid incubating media was applied to investigate the influence air-media interface area on accuracy of measuring the oxygen intake and error value. It was shown that intrusion of air oxygen increases the relative error to 24% in open polarographic cells and to 13% in cells with a reduced interface area. Results of modeling passive media oxygenation laid a basis for proposing a method to reduce relative error by 66% for open cells and by 15% for cells with a reduced interface area.

  19. Broadband modulation of terahertz waves through electrically driven hybrid bowtie antenna-VO2 devices.

    Science.gov (United States)

    Han, Chunrui; Parrott, Edward P J; Humbert, Georges; Crunteanu, Aurelian; Pickwell-MacPherson, Emma

    2017-10-05

    Broadband modulation of terahertz (THz) light is experimentally realized through the electrically driven metal-insulator phase transition of vanadium dioxide (VO 2 ) in hybrid metal antenna-VO 2 devices. The devices consist of VO 2 active layers and bowtie antenna arrays, such that the electrically driven phase transition can be realized by applying an external voltage between adjacent metal wires extended to a large area array. The modulation depth of the terahertz light can be initially enhanced by the metal wires on top of VO 2 and then improved through the addition of specific bowties in between the wires. As a result, a terahertz wave with a large beam size (~10 mm) can be modulated within the measurable spectral range (0.3-2.5 THz) with a frequency independent modulation depth as high as 0.9, and the minimum amplitude transmission down to 0.06. Moreover, the electrical switch on/off phase transition depends very much on the size of the VO 2 area, indicating that smaller VO 2 regions lead to higher modulation speeds and lower phase transition voltages. With the capabilities in actively tuning the beam size, modulation depth, modulation bandwidth as well as the modulation speed of THz waves, our study paves the way in implementing multifunctional components for terahertz applications.

  20. VO2 microcrystals as an advanced smart window material at semiconductor to metal transition

    Science.gov (United States)

    Basu, Raktima; Magudapathy, P.; Sardar, Manas; Pandian, Ramanathaswamy; Dhara, Sandip

    2017-11-01

    Textured VO2(0 1 1) microcrystals are grown in the monoclinic, M1 phase which undergoes a reversible first order semiconductor to metal transition (SMT) accompanied by a structural phase transition to rutile tetragonal, R phase. Around the phase transition, VO2 also experiences noticeable change in its optical and electrical properties. A change in color of the VO2 micro crystals from white to cyan around the transition temperature is observed, which is further understood by absorption of red light using temperature dependent ultraviolet-visible spectroscopic analysis and photoluminescence studies. The absorption of light in the red region is explained by the optical transition between Hubbard states, confirming the electronic correlation as the driving force for SMT in VO2. The thermochromism in VO2 has been studied for smart window applications so far in the IR region, which supports the opening of the band gap in semiconducting phase; whereas there is hardly any report in the management of visible light. The filtering of blue light along with reflection of infrared above the semiconductor to metal transition temperature make VO2 applicable as advanced smart windows for overall heat management of a closure.

  1. VO2 microcrystals as an advanced smart window material at semiconductor to metal transition

    International Nuclear Information System (INIS)

    Basu, Raktima; Pandian, Ramanathaswamy; Dhara, Sandip; Magudapathy, P; Sardar, Manas

    2017-01-01

    Textured VO 2 (0 1 1) microcrystals are grown in the monoclinic, M1 phase which undergoes a reversible first order semiconductor to metal transition (SMT) accompanied by a structural phase transition to rutile tetragonal, R phase. Around the phase transition, VO 2 also experiences noticeable change in its optical and electrical properties. A change in color of the VO 2 micro crystals from white to cyan around the transition temperature is observed, which is further understood by absorption of red light using temperature dependent ultraviolet–visible spectroscopic analysis and photoluminescence studies. The absorption of light in the red region is explained by the optical transition between Hubbard states, confirming the electronic correlation as the driving force for SMT in VO 2 . The thermochromism in VO 2 has been studied for smart window applications so far in the IR region, which supports the opening of the band gap in semiconducting phase; whereas there is hardly any report in the management of visible light. The filtering of blue light along with reflection of infrared above the semiconductor to metal transition temperature make VO 2 applicable as advanced smart windows for overall heat management of a closure. (paper)

  2. Familial aggregation of VO(2max) response to exercise training: results from the HERITAGE Family Study.

    Science.gov (United States)

    Bouchard, C; An, P; Rice, T; Skinner, J S; Wilmore, J H; Gagnon, J; Pérusse, L; Leon, A S; Rao, D C

    1999-09-01

    The aim of this study was to test the hypothesis that individual differences in the response of maximal O(2) uptake (VO(2max)) to a standardized training program are characterized by familial aggregation. A total of 481 sedentary adult Caucasians from 98 two-generation families was exercise trained for 20 wk and was tested for VO(2max) on a cycle ergometer twice before and twice after the training program. The mean increase in VO(2max) reached approximately 400 ml/min, but there was considerable heterogeneity in responsiveness, with some individuals experiencing little or no gain, whereas others gained >1.0 l/min. An ANOVA revealed that there was 2.5 times more variance between families than within families in the VO(2max) response variance. With the use of a model-fitting procedure, the most parsimonious models yielded a maximal heritability estimate of 47% for the VO(2max) response, which was adjusted for age and sex with a maternal transmission of 28% in one of the models. We conclude that the trainability of VO(2max) is highly familial and includes a significant genetic component.

  3. Thermochromic VO2 thin films deposited by magnetron sputtering for smart window applications

    Science.gov (United States)

    Fortier, Jean-Philippe

    "Smart" windows are a perfect innovative example of technology that reduces our energy dependence and our impact on the environment while saving on the economical point of view. With the use of vanadium dioxide (VO2), a thermochromic compound, and this, as a thin coating, it would in fact be possible to control the sun's transmission of infrared light (heat) as a function of the surrounding environment temperature. In other words, its optical behavior would allow a more effective management of heat exchanges between a living venue and the outdoor environment. However, this type of window is still in a developmental stage. First, the oxide's deposition is not simple in nature. Based on a conventional deposition technique called magnetron sputtering mainly used in the fenestration industry, several factors such as the oxygen concentration and the substrate temperature during deposition can affect the coating's thermochromic behavior, and this, by changing its composition and crystallinity. Other control parameters such as the deposition rate, the pressure in the sputtering chamber and the choice of substrate may also modify the film microstructure, thereby varying its optical and electrical properties. In addition, several issues still persist as to its commercial application. For starters, the material's structural transition, related to the change of its optical properties, only occurs around 68°C. In addition, its low transparency and natural greenish colour are not visually appealing. Then, to this day, the deposition temperature required to crystallize and form the thermochromic oxide remains an obstacle for a possible large-scale application. Ultimately, although the material's change in temperature has been shown to be advantageous in situations of varying climate, the existing corrective solutions to these issues generate a deterioration of the thermochromic behavior. With no practical expertise on the material, this project was undertaken with certain

  4. Associations between VO2max and vitality in older workers: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    van der Beek Allard J

    2010-11-01

    Full Text Available Abstract Background To prevent early exit from work, it is important to study which factors contribute to healthy ageing. One concept that is assumed to be closely related to, and therefore may influence healthy ageing, is vitality. Vitality consists of both a mental and a physical component, and is characterised by a perceived high energy level, decreased feelings of fatigue, and feeling fit. Since VO2max gives an indication of one's aerobic fitness, which can be improved by increased levels of physical activity, and because feeling fit is one of the main characteristics of vitality, it is hypothesised that VO2max is related to vitality. Therefore, the aim of this study was to investigate the associations between VO2max and vitality. Methods In 427 older workers (aged 45 + years participating in the Vital@Work study, VO2max was estimated at baseline using the 2-km UKK walk test. Vitality was measured by both the UWES Vitality Scale and the RAND-36 Vitality Scale. Associations were analysed using linear regression analyses. Results The linear regression models, adjusted for age, showed a significant association between VO2max and vitality measured with the RAND-36 Vitality Scale (β = 0.446; 95% CI: 0.220-0.673. There was no significant association between VO2max and vitality measured with the UWES (β = -0.006; 95% CI:-0.017 - 0.006, after adjusting for age, gender and chronic disease status. Conclusions VO2max was associated with a general measure of vitality (measured with the RAND-36 Vitality Scale, but not with occupational health related vitality (measured with the UWES Vitality Scale. The idea that physical exercise can be used as an effective tool for improving vitality was supported in this study. Trial registration NTR1240

  5. Associations between VO2max and vitality in older workers: a cross-sectional study.

    Science.gov (United States)

    Strijk, Jorien E; Proper, Karin I; Klaver, Linda; van der Beek, Allard J; van Mechelen, Willem

    2010-11-09

    To prevent early exit from work, it is important to study which factors contribute to healthy ageing. One concept that is assumed to be closely related to, and therefore may influence healthy ageing, is vitality. Vitality consists of both a mental and a physical component, and is characterised by a perceived high energy level, decreased feelings of fatigue, and feeling fit. Since VO2max gives an indication of one's aerobic fitness, which can be improved by increased levels of physical activity, and because feeling fit is one of the main characteristics of vitality, it is hypothesised that VO2max is related to vitality. Therefore, the aim of this study was to investigate the associations between VO2max and vitality. In 427 older workers (aged 45 + years) participating in the Vital@Work study, VO2max was estimated at baseline using the 2-km UKK walk test. Vitality was measured by both the UWES Vitality Scale and the RAND-36 Vitality Scale. Associations were analysed using linear regression analyses. The linear regression models, adjusted for age, showed a significant association between VO2max and vitality measured with the RAND-36 Vitality Scale (β = 0.446; 95% CI: 0.220-0.673). There was no significant association between VO2max and vitality measured with the UWES (β = -0.006; 95% CI:-0.017 - 0.006), after adjusting for age, gender and chronic disease status. VO2max was associated with a general measure of vitality (measured with the RAND-36 Vitality Scale), but not with occupational health related vitality (measured with the UWES Vitality Scale). The idea that physical exercise can be used as an effective tool for improving vitality was supported in this study. NTR1240.

  6. Sex differences in the effects of 12 weeks sprint interval training on body fat mass and the rates of fatty acid oxidation and VO2max during exercise.

    Science.gov (United States)

    Bagley, Liam; Slevin, Mark; Bradburn, Steven; Liu, Donghui; Murgatroyd, Chris; Morrissey, George; Carroll, Michael; Piasecki, Mathew; Gilmore, William S; McPhee, Jamie S

    2016-01-01

    The purpose of this study was to examine whether very short duration, very high intensity sprint interval training (SIT) leads to loss of body fat mass in association with improvements to VO 2 max and fatty acid oxidation, and to assess the extent of sex dimorphism in these physiological responses. A total of 24 men and 17 women (mean (SEM) age: 39 (±2) years; body mass index 24.6 (0.6)) completed measurements of the maximal rate of oxygen uptake (VO 2 max) and fatty acid oxidation (FATmax). Body fat and lean mass were measured by dual emission x-ray absorptiometry, and fasting blood lipid, glucose and insulin profiles were assessed before and after training. SIT consisted of 4×20 s sprints on a cycle ergometer at approximately 175% VO 2 max, three times per week for 12 weeks. Fat mass decreased by 1.0 kg, although men lost statistically significantly more fat than women both when expressed in Kg and as % body fat. VO 2 max increased by around 9%, but women improved VO 2 max significantly more than men. FATmax improved by around 13%, but fasting plasma glucose, insulin, total triglyceride, total cholesterol and high-density lipoprotein (HDL) did not change after training, while low-density lipoprotein decreased by 8% (p=0.028) and the HDL:Total Cholesterol ratio improved by 6%. There were no sex differences in these metabolic responses to training. These results show lower body fat %, and higher rates of fatty acid oxidation and VO 2 max after 12 weeks of training for just 4 min per week. Notably, women improved VO 2 max more than men, while men lost more fat than women.

  7. Sex differences in the effects of 12 weeks sprint interval training on body fat mass and the rates of fatty acid oxidation and VO2max during exercise

    Science.gov (United States)

    Bagley, Liam; Slevin, Mark; Bradburn, Steven; Liu, Donghui; Murgatroyd, Chris; Morrissey, George; Carroll, Michael; Piasecki, Mathew; Gilmore, William S; McPhee, Jamie S

    2016-01-01

    Background The purpose of this study was to examine whether very short duration, very high intensity sprint interval training (SIT) leads to loss of body fat mass in association with improvements to VO2max and fatty acid oxidation, and to assess the extent of sex dimorphism in these physiological responses. Methods A total of 24 men and 17 women (mean (SEM) age: 39 (±2) years; body mass index 24.6 (0.6)) completed measurements of the maximal rate of oxygen uptake (VO2max) and fatty acid oxidation (FATmax). Body fat and lean mass were measured by dual emission x-ray absorptiometry, and fasting blood lipid, glucose and insulin profiles were assessed before and after training. SIT consisted of 4×20 s sprints on a cycle ergometer at approximately 175% VO2max, three times per week for 12 weeks. Results Fat mass decreased by 1.0 kg, although men lost statistically significantly more fat than women both when expressed in Kg and as % body fat. VO2max increased by around 9%, but women improved VO2max significantly more than men. FATmax improved by around 13%, but fasting plasma glucose, insulin, total triglyceride, total cholesterol and high-density lipoprotein (HDL) did not change after training, while low-density lipoprotein decreased by 8% (p=0.028) and the HDL:Total Cholesterol ratio improved by 6%. There were no sex differences in these metabolic responses to training. Conclusions These results show lower body fat %, and higher rates of fatty acid oxidation and VO2max after 12 weeks of training for just 4 min per week. Notably, women improved VO2max more than men, while men lost more fat than women. PMID:27900150

  8. Supercapacitors based on two dimensional VO2 nanosheet electrodes in organic gel electrolyte

    KAUST Repository

    Rakhi, R.B.

    2016-10-16

    VO2 is a low band-gap semiconductor with relatively high conductivity among transition metal oxides, which makes it an interesting material for supercapacitor electrode applications. The performance of VO2 as supercapacitor electrode in organic electrolytes has never been reported before. Herein, two-dimensional nanosheets of VO2 are prepared by the simultaneous solution reduction and exfoliation from bulk V2O5 powder by hydrothermal method. A specific capacitance of 405 Fg−1 is achieved for VO2 based supercapacitor in an organic electrolyte, in three electrode configuration. The symmetric capacitor based on VO2 nanosheet electrodes and the liquid organic electrolyte exhibits an energy density of 46 Wh kg−1 at a power density of 1.4 kW kg−1 at a constant current density of 1 Ag−1. Furthermore, flexible solid-state supercapacitors are fabricated using same electrode material and Alumina-silica based gel electrolyte. The solid-state device delivers a specific capacitance of 145 Fg−1 and a device capacitance of 36 Fg−1 at a discharge current density of 1 Ag−1. Series combination of three solid state capacitors is capable of lighting up a red LED for more than 1 minute.

  9. The effect of Iron Supplying on VO2 MAX and Haematology Parameter on Menstrual Woman

    Science.gov (United States)

    Nailuvar Sinaga, Rika; Sari Harahap, Novita; Mediyana Sari, Rima

    2018-03-01

    One of the supporting factors to have good aerobic endurance requires high VO2 max levels supported by good quality and quantity level of Haematology parameter especially such as erythrocytes, hematocrit and hemoglobin. One of the components in hemoglobin is iron which functions as theoxygen transport to parts of all body required in the process of metabolism. The objective of this research was to find out the difference between VO2 Max and Haematology parameter between iron supplying and no iron supplyingonmenstrual woman. The type of this research is quasi experimental research with non-randomized control group Pretest-Postest Design. The subjectsarethe studentsat faculty of Sports Sciences, Medan State University with the criteria of female gender, monthly regular menstrual cycle, having the level of health and the level of training, willing to be a sample by filling out informed consent. The total number of research subjectsis twenty students, divided into two groups namely the treatment group and the control group. The hematology parameter was measuredby Haemotology analyzer and VO2 Max was measured by multi-stage run. The result showed that there was a significant effect of iron supplyingon the increase of erythrocyte level on menstrual women, hemotocrit, haemoglobin and an increase in VO2 Max. Iron supplying on menstrual woman has the effect on the increase of erythrocyte, hematocrit, hemoglobin level and VO2 Max

  10. Optical switching properties of VO2 films driven by using WDM-aligned lasers

    International Nuclear Information System (INIS)

    Tsai, K.Y.; Wu, F.-H.; Shieh, H.-P.D.; Chin, T.-S.

    2006-01-01

    Vanadium dioxide (VO 2 ) film had been demonstrated a high speed IR shutter driven by total optical modulation. However, it usually required a higher power heating laser of high power and precise optical systems to cover the probe beam on the sample with a heating beam of larger area. A new optical system, simply composed of wavelength division multiplexing (WDM), fiber lens or convex lens system, and a glass sheet with VO 2 thin film on it, was easily assembled to utilize VO 2 film as an IR shutter, implying the possibility to highly miniaturize the VO 2 -based optical shutter. A permanent low-transmittance (PLT) region forms on the film within the probe beam, resulting in a decrease in average power of the probe beam. Another ring-type switching area (switching ring) forms around the PLT region, resulting in the transmittance switching of the probe beam synchronously with the heating signal. VO 2 films can be switched with the highest rate of a continuous square heating signal of 3 mW at 120 kHz. A heating pulse of 0.7 ns and 13 mW can be used to stimulate an IR pulse with fiber lens

  11. Effects of erythrocyte infusion on VO2max at high altitude

    DEFF Research Database (Denmark)

    Young, Jette Feveile; Sawka, M N; Muza, S R

    1996-01-01

    This study investigated whether autologous erythrocyte infusion would ameliorate the decrement in maximal O2 uptake (VO2max) experienced by lowlanders when they ascend to high altitude. VO2max was measured in 16 men (treadmill running) at sea level (SL) and on the 1st (HA1) and 9th (HA9) days...... of high-altitude (4,300 m) residence. After VO2max was measured at SL, subjects were divided into two matched groups (n = 8). Twenty-four hours before ascent to high altitude, the experimental group received a 700-ml infusion of autologous erythrocytes and saline (42% hematocrit), whereas the control...... group received only saline. The VO2max of erythrocyte-infused [54 +/- 1 (SE) ml.kg-1.min-1] and control subjects (52 +/- 2 ml.kg-1.min-1) did not differ at SL before infusion. The decrement in VO2max on HA1 did not differ between groups, averaging 26% overall, despite higher (P

  12. The effect of short-term dimethylglycine treatment on oxygen consumption in cytochrome oxidase deficiency: a double-blind randomized crossover clinical trial.

    Science.gov (United States)

    Liet, Jean-Michel; Pelletier, Véronique; Robinson, Brian H; Laryea, Maurice D; Wendel, Udo; Morneau, Sylvain; Morin, Charles; Mitchell, Grant; Lacroix, Jacques

    2003-01-01

    To study the effectiveness of dimethylglycine (DMG) on oxygen consumption (VO(2)) in children with Saguenay-Lac-Saint-Jean cytochrome-c oxidase (SLSJ-COX) deficiency (OMIM 220111). In a crossover randomized double-blind clinical trial, 5 children with SLSJ-COX deficiency, who were stable and old enough to comply with VO(2) measurement, were treated with placebo or DMG for 3 days, and with the alternate treatment after a 2-week washout period. VO(2) was measured by indirect calorimetry before and after treatment. Dietary caloric intake was calculated for 3 days before each measurement. Mean caloric intakes per day were 1562 and 1342 kcal x m(-2) before and during placebo, 1,336 and 1,380 before and during DMG, respectively. DMG was well tolerated and, in all cases, resulted in markedly increased blood DMG levels (617 + 203 mmol x L(-1)), versus 0 to 2 mmol x L(-1) without treatment. Mean VO(2) was lower after administration of either DMG (-1 +/- 3 mL x min(-1) x m(-2)) or placebo (-6 +/- 4), but neither difference was statistically significant. There was no detectable effect of DMG treatment on blood levels of lactate, pyruvate, bicarbonate, or pH. VO(2) values of patients (range, 101-135 mL x min(-1) x m(-2)) were lower than published norms (150-160 mL x min(-1) x m(-2)). This study suggests that treatment with DMG does not substantially change VO(2) in children with SLSJ-COX deficiency.

  13. Relationship between running kinematic changes and time limit at vVO2max. DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n4p428

    Directory of Open Access Journals (Sweden)

    Sebastião Iberes Lopes Melo

    2012-07-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n4p428Exhaustive running at maximal oxygen uptake velocity (vVO2max can alter running kinematic parameters and increase energy cost along the time. The aims of the present study were to compare characteristics of ankle and knee kinematics during running at vVO2max and to verify the relationship between changes in kinematic variables and time limit (Tlim. Eleven male volunteers, recreational players of team sports, performed an incremental running test until volitional exhaustion to determine vVO2max and a constant velocity test at vVO2max. Subjects were filmed continuously from the left sagittal plane at 210 Hz for further kinematic analysis. The maximal plantar flexion during swing (p<0.01 was the only variable that increased significantly from beginning to end of the run. Increase in ankle angle at contact was the only variable related to Tlim (r=0.64; p=0.035 and explained 34% of the performance in the test. These findings suggest that the individuals under study maintained a stable running style at vVO2max and that increase in plantar flexion explained the performance in this test when it was applied in non-runners.

  14. Thermally tunable broadband omnidirectional and polarization-independent super absorber using phase change material VO2

    Directory of Open Access Journals (Sweden)

    Zhejun Liu

    Full Text Available In this letter, we numerically demonstrate a thermally tunable super absorber by using phase change material VO2 as absorbing layer in metal-insulator-metal structure. An omnidirectional super absorption at λ=2.56μm can be realized by heating the patterned grating VO2 film due to magnetic resonance mechanism. Furthermore, a broadband super absorption higher than 0.8 in the entire 1.6μm–4μm region is achieved when VO2 film is patterned chessboard structure and transformed to metal phase beyond transition temperature. This broadband super absorption can be fulfilled in a wide range of incident angle (0°–70° and under all polarization conditions. Keywords: Phase change material, Metal-insulator-metal, Super absorption, Magnetic resonance

  15. Tunable subwavelength hot spot of dipole nanostructure based on VO2 phase transition.

    Science.gov (United States)

    Park, Jun-Bum; Lee, Il-Min; Lee, Seung-Yeol; Kim, Kyuho; Choi, Dawoon; Song, Eui Young; Lee, Byoungho

    2013-07-01

    We propose a novel approach to generate and tune a hot spot in a dipole nanostructure of vanadium dioxide (VO2) laid on a gold (Au) substrate. By inducing a phase transition of the VO2, the spatial and spectral distributions of the hot spot generated in the feed gap of the dipole can be tuned. Our numerical simulation based on a finite-element method shows a strong intensity enhancement difference and tunability near the wavelength of 678 nm, where the hot spot shows 172-fold intensity enhancement when VO2 is in the semiconductor phase. The physical mechanisms of forming the hot spots at the two-different phases are discussed. Based on our analysis, the effects of geometric parameters in our dipole structure are investigated with an aim of enhancing the intensity and the tunability. We hope that the proposed nanostructure opens up a practical approach for the tunable near-field nano-photonic devices.

  16. Microwave assisted growth of nanorods vanadium dioxide VO2 (R): structural and electrical properties

    Science.gov (United States)

    Derkaoui, I.; Khenfouch, M.; Mothudi, B. M.; Moloi, S. J.; Zorkani, I.; Jorio, A.; Maaza, M.

    2018-03-01

    Nanostructured metal oxides have attracted a lot of attention recently owning to their unique structural advantages and demonstrated promising chemical and physical properties for various applications. In this study, we report the structural and electrical properties of vanadium dioxide VO2 (R) prepared via a single reaction microwave (SRC) synthesis. Our results are revealing that the components of VO2 (R) films have a rod-like shape with a uniform size distribution. The nanorods with very smooth and flat surfaces have a typical length of up to 2μm and a width of about several nanometers. The structural investigations reveal the high crystallinity of VO2 (R) ensuring good electrical contact and showing a high conductivity as a function of temperature. This synthesis method provides a new simple route to fabricate one-dimensional nanostructured metal oxides which is suitable for a large field of applications especially for smart windows.

  17. Gate voltage controlled humidity sensing using MOSFET of VO2 particles

    CSIR Research Space (South Africa)

    Akande, Amos A

    2017-01-01

    Full Text Available (A), VO2 (AH) [4], [5] and M2 the intermediate phase between M1 and R phase. These phases have been generally useful in technologies such as thermal switch (thermochromic window), thermal/infrared sensors, A.A Akande holds PhD studentship...) is 272.1, A1 and A2 are respectively 0.118 and 12096 with a correlation coefficient, R2, of 0.925. These results suggest that the VO2 sensor is very resilient to humidity such that it does not saturate even when humidity approaches 100%. This sensor...

  18. Impact of growth temperature on the crystal habits, forms and structures of VO2 nanocrystals

    International Nuclear Information System (INIS)

    Loeffler, Stefan; Auer, Erwin; Lugstein, Alois; Bertagnolli, Emmerich; Weil, Matthias

    2011-01-01

    We investigated the impact of the process temperature on the habits, forms and crystal structure of VO 2 nanocrystals grown by a vapor-transport method on (0001) quartz substrates. Four distinct growth regimes were discerned: orthorhombic nanowires, sheets, hemispheres, and nanowires with a monoclinic structure. The nanostructures were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), and transmission electron microscopy (TEM). I/V characterization of individual nanowires was enabled by Ti/Au contact formation via electron beam lithography and lift-off techniques. The expected metal-insulator transition (MIT) was found in monoclinic VO 2 nanowires. (orig.)

  19. Metal-insulator phase transition in a VO2 thin film observed with terahertz spectroscopy

    DEFF Research Database (Denmark)

    Jepsen, Peter Uhd; Fischer, Bernd M.; Thoman, Andreas

    2006-01-01

    We investigate the dielectric properties of a thin VO2 film in the terahertz frequency range in the vicinity of the semiconductor-metal phase transition. Phase-sensitive broadband spectroscopy in the frequency region below the phonon bands of VO2 gives insight into the conductive properties...... of the film during the phase transition. We compare our experimental data with models proposed for the evolution of the phase transition. The experimental data show that the phase transition occurs via the gradual growth of metallic domains in the film, and that the dielectric properties of the film...

  20. VV and VO2 defects in silicon studied with hybrid density functional theory

    KAUST Repository

    Christopoulos, Stavros Richard G; Wang, Hao; Chroneos, Alexander I.; Londos, Charalampos A.; Sgourou, Efstratia N.; Schwingenschlö gl, Udo

    2014-01-01

    The formation of VO (A-center), VV and VO2 defects in irradiated Czochralski-grown silicon (Si) is of technological importance. Recent theoretical studies have examined the formation and charge states of the A-center in detail. Here we use density

  1. Femtosecond Near Edge X-ray Absorption Measurement of the VO2 Phase Transition

    International Nuclear Information System (INIS)

    Cavalleri, A.; Chong, H.H.W.; Fourmaux, S.; Glover, T.E.; Heimann, P.A; Kieffer, J.C.; Padmore, H.A.; Schoenlein, R.W.

    2004-01-01

    The authors measure the insulator-to-metal transition in VO 2 using femtosecond Near-Edge X-ray Absorption. Sliced pulses of synchrotron radiation are used to detect the photo-induced dynamics at the 516-eV Vanadium L 3 edge

  2. Hydrothermal route to VO2 (B) nanorods: controlled synthesis and characterization

    Science.gov (United States)

    Song, Shaokun; Huang, Qiwei; Zhu, Wanting

    2017-10-01

    One-dimensional vanadium dioxides have attracted intensive attention owing to their distinctive structure and novel applications in catalysis, high energy lithium-ion batteries, chemical sensors/actuators and electrochemical devices etc. In this paper, large-scale VO2 (B) nanorods have been successfully synthesized via a versatile and environment friendly hydrothermal strategy using V2O5 as vanadium source and carbohydrates/alcohols as reductant. The obtained samples are characterized by XRD, FT-IR, TEM, and XPS techniques to investigate the effects of chemical parameters such as reductants, temperature, and time of synthesis on the structure and morphology of products. Results show that pure B phase VO2 with homogeneous nanorod-like morphology can be prepared easily at 180 °C for 3 days with glycerol as reluctant. Typically, the nanorod-like products are 0.5-1 μm long and 50 nm width. Furthermore, it is also confirmed that the products are consisted of VO2, corresponding to the B phase. More importantly, this novel approach is efficient, free of any harmful solvents and surfactants. Therefore, this efficient, green, and cost-saving route will have great potential in the large-scale fabrication of 1D VO2 (B) nanorods from the economic and environmental point of view.

  3. Metal-Insulator Phase Transition in Quasi-One-Dimensional VO2 Structures

    Directory of Open Access Journals (Sweden)

    Woong-Ki Hong

    2015-01-01

    Full Text Available The metal-insulator transition (MIT in strongly correlated oxides has attracted considerable attention from both theoretical and experimental researchers. Among the strongly correlated oxides, vanadium dioxide (VO2 has been extensively studied in the last decade because of a sharp, reversible change in its optical, electrical, and magnetic properties at approximately 341 K, which would be possible and promising to develop functional devices with advanced technology by utilizing MITs. However, taking the step towards successful commercialization requires the comprehensive understanding of MIT mechanisms, enabling us to manipulate the nature of transitions. In this regard, recently, quasi-one-dimensional (quasi-1D VO2 structures have been intensively investigated due to their attractive geometry and unique physical properties to observe new aspects of transitions compared with their bulk counterparts. Thus, in this review, we will address recent research progress in the development of various approaches for the modification of MITs in quasi-1D VO2 structures. Furthermore, we will review recent studies on realizing novel functional devices based on quasi-1D VO2 structures for a wide range of applications, such as a gas sensor, a flexible strain sensor, an electrical switch, a thermal memory, and a nonvolatile electrical memory with multiple resistance.

  4. Characteristics of the Current-Controlled Phase Transition of VO2 Microwires for Hybrid Optoelectronic Devices

    Directory of Open Access Journals (Sweden)

    Arash Joushaghani

    2015-08-01

    Full Text Available The optical and electrical characteristics of the insulator-metal phase transition of vanadium dioxide (VO2 enable the realization of power-efficient, miniaturized hybrid optoelectronic devices. This work studies the current-controlled, two-step insulator-metal phase transition of VO2 in varying microwire geometries. Geometry-dependent scaling trends extracted from current-voltage measurements show that the first step induced by carrier injection is delocalized over the microwire, while the second, thermally-induced step is localized to a filament about 1 to 2 μm wide for 100 nm-thick sputtered VO2 films on SiO2. These effects are confirmed by direct infrared imaging, which also measures the change in optical absorption in the two steps. The difference between the threshold currents of the two steps increases as the microwires are narrowed. Micron- and sub-micron-wide VO2 structures can be used to separate the two phase transition steps in photonic and electronic devices.

  5. Ultrafast electron-lattice coupling dynamics in VO2 and V2O3 thin films

    Science.gov (United States)

    Abreu, Elsa; Gilbert Corder, Stephanie N.; Yun, Sun Jin; Wang, Siming; Ramírez, Juan Gabriel; West, Kevin; Zhang, Jingdi; Kittiwatanakul, Salinporn; Schuller, Ivan K.; Lu, Jiwei; Wolf, Stuart A.; Kim, Hyun-Tak; Liu, Mengkun; Averitt, Richard D.

    2017-09-01

    Ultrafast optical pump-optical probe and optical pump-terahertz probe spectroscopy were performed on vanadium dioxide (VO2) and vanadium sesquioxide (V2O3 ) thin films over a wide temperature range. A comparison of the experimental data from these two different techniques and two different vanadium oxides, in particular a comparison of the spectral weight oscillations generated by the photoinduced longitudinal acoustic modulation, reveals the strong electron-phonon coupling that exists in both materials. The low-energy Drude response of V2O3 appears more amenable than VO2 to ultrafast strain control. Additionally, our results provide a measurement of the temperature dependence of the sound velocity in both systems, revealing a four- to fivefold increase in VO2 and a three- to fivefold increase in V2O3 across the insulator-to-metal phase transition. Our data also confirm observations of strong damping and phonon anharmonicity in the metallic phase of VO2, and suggest that a similar phenomenon might be at play in the metallic phase of V2O3 . More generally, our simple table-top approach provides relevant and detailed information about dynamical lattice properties of vanadium oxides, paving the way to similar studies in other complex materials.

  6. Adhesion characteristics of VO2 ink film sintered by intense pulsed light for smart window

    Science.gov (United States)

    Youn, Ji Won; Lee, Seok-Jae; Kim, Kwang-Seok; Kim, Dae Up

    2018-05-01

    Progress in the development of energy-efficient coatings on glass has led to the research of smart windows that can modulate solar energy in response to an external stimulus like light, heat, or electricity. Thermochromic smart windows have attracted great interest because they provide highly visible transparency and intelligently controllable solar heat. VO2 has been widely used as coating material for thermochromism owing to its reversible metal-to-insulator transition near room temperature. However, unstable crystalline phases and expensive fabrication processes of VO2 films limit their facile application in smart windows. To overcome these restrictions, we manufactured nanoinks based on VO2 nanoparticles and fabricated films using spin coating and intense pulsed light (IPL) sintering on a quartz substrate. We examined adhesion between the VO2 nanoink films and the quartz substrate by varying the applied voltages and the number of pulses. The average adhesion of thin films increased to 83 and 108 N/m as the applied voltage during IPL sintering increased from 1400 to 2000 V. By increasing the number of pulses from 5 to 20, the adhesive strength increased from 83 to 94 N/m at 1400 V, and decreased from 108 to 96 N/m at 2000 V voltage.

  7. VO2-based radiative thermal transistor with a semi-transparent base

    Science.gov (United States)

    Prod'homme, Hugo; Ordonez-Miranda, Jose; Ezzahri, Younès; Drévillon, Jérémie; Joulain, Karl

    2018-05-01

    We study a radiative thermal transistor analogous to an electronic one made of a VO2 base placed between two silica semi-infinite plates playing the roles of the transistor collector and emitter. The fact that VO2 exhibits an insulator to metal transition is exploited to modulate and/or amplify heat fluxes between the emitter and the collector, by applying a thermal current on the VO2 base. We extend the work of precedent studies considering the case where the base can be semi-transparent so that heat can be exchanged directly between the collector and the emitter. Both near and far field cases are considered leading to 4 typical regimes resulting from the fact that the emitter-base and base-collector separation distances can be larger or smaller than the thermal wavelength for a VO2 layer opaque or semi-transparent. Thermal currents variations with the base temperatures are calculated and analyzed. It is found that the transistor can operate in an amplification mode as already stated in [1] or in a switching mode as seen in [2]. An optimum configuration for the base thickness and separation distance maximizing the thermal transistor modulation factor is found.

  8. Gate-tunable gigantic changes in lattice parameters and optical properties in VO2

    Science.gov (United States)

    Nakano, Masaki; Okuyama, Daisuke; Shibuya, Keisuke; Ogawa, Naoki; Hatano, Takafumi; Kawasaki, Masashi; Arima, Taka-Hisa; Iwasa, Yoshihiro; Tokura, Yoshinori

    2014-03-01

    The field-effect transistor provides an electrical switching function of current flowing through a channel surface by external gate voltage (VG). We recently reported that an electric-double-layer transistor (EDLT) based on vanadium dioxide (VO2) enables electrical switching of the metal-insulator phase transition, where the low-temperature insulating state can be completely switched to the metallic state by application of VG. Here we demonstrate that VO2-EDLT enables electrical switching of lattice parameters and optical properties as well as electrical current. We performed in-situ x-ray diffraction and optical transmission spectroscopy measurements, and found that the c-axis length and the infrared transmittance of VO2 can be significantly modulated by more than 1% and 40%, respectively, by application of VG. We emphasize that these distinguished features originate from the electric-field induced bulk phase transition available with VO2-EDLT. This work was supported by the Japan Society for the Promotion of Science (JSPS) through its ``Funding Program for World-Leading Innovative R&D on Science and Technology (FIRST Program).''

  9. Surface charge sensing by altering the phase transition in VO2

    Science.gov (United States)

    Kumar, S.; Esfandyarpour, R.; Davis, R.; Nishi, Y.

    2014-08-01

    Detection of surface charges has various applications in medicine, electronics, biotechnology, etc. The source of surface charge induction may range from simple charge-polarized molecules like water to complicated proteins. It was recently discovered that surface charge accumulation can alter the temperature at which VO2 undergoes a Mott transition. Here, we deposited polar molecules onto the surface of two-terminal thin-film VO2 lateral devices and monitored the joule-heating-driven Mott transition, or conductance switching. We observed that the power required to induce the conductance switching reduced upon treatment with polar molecules and, using in-situ blackbody-emission direct measurement of local temperature, we show that this reduction in power was accompanied by reduction in the Mott transition temperature. Further evidence suggested that this effect has specificity to the nature of the species used to induce surface charges. Using x-ray absorption spectroscopy, we also show that there is no detectable change in oxidation state of vanadium or structural phase in the bulk of the 40 nm VO2 thin-film even as the phase transition temperature is reduced by up to 20 K by the polar molecules. The ability to alter the phase transition parameters by depositing polar molecules suggests a potential application in sensing surface charges of different origins and this set of results also highlights interesting aspects of the phase transition in VO2.

  10. Impact of hypothalamic reactive oxygen species in the control of energy metabolism and food intake

    Directory of Open Access Journals (Sweden)

    Anne eDrougard

    2015-02-01

    Full Text Available Hypothalamus is a key area involved in the control of metabolism and food intake via the integrations of numerous signals (hormones, neurotransmitters, metabolites from various origins. These factors modify hypothalamic neurons activity and generate adequate molecular and behavioral responses to control energy balance. In this complex integrative system, a new concept has been developed in recent years, that includes reactive oxygen species (ROS as a critical player in energy balance. ROS are known to act in many signaling pathways in different peripheral organs, but also in hypothalamus where they regulate food intake and metabolism by acting on different types of neurons, including proopiomelanocortin (POMC and agouti-related protein (AgRP/neuropeptide Y (NPY neurons. Hypothalamic ROS release is under the influence of different factors such as pancreatic and gut hormones, adipokines (leptin, apelin,..., neurotransmitters and nutrients (glucose, lipids,.... The sources of ROS production are multiple including NADPH oxidase, but also the mitochondria which is considered as the main ROS producer in the brain. ROS are considered as signaling molecules, but conversely impairment of this neuronal signaling ROS pathway contributes to alterations of autonomic nervous system and neuroendocrine function, leading to metabolic diseases such as obesity and type 2 diabetes.In this review we focus our attention on factors that are able to modulate hypothalamic ROS release in order to control food intake and energy metabolism, and whose deregulations could participate to the development of pathological conditions. This novel insight reveals an original mechanism in the hypothalamus that controls energy balance and identify hypothalamic ROS signaling as a potential therapeutic strategy to treat metabolic disorders.

  11. Impact of hypothalamic reactive oxygen species in the regulation of energy metabolism and food intake.

    Science.gov (United States)

    Drougard, Anne; Fournel, Audren; Valet, Philippe; Knauf, Claude

    2015-01-01

    Hypothalamus is a key area involved in the control of metabolism and food intake via the integrations of numerous signals (hormones, neurotransmitters, metabolites) from various origins. These factors modify hypothalamic neurons activity and generate adequate molecular and behavioral responses to control energy balance. In this complex integrative system, a new concept has been developed in recent years, that includes reactive oxygen species (ROS) as a critical player in energy balance. ROS are known to act in many signaling pathways in different peripheral organs, but also in hypothalamus where they regulate food intake and metabolism by acting on different types of neurons, including proopiomelanocortin (POMC) and agouti-related protein (AgRP)/neuropeptide Y (NPY) neurons. Hypothalamic ROS release is under the influence of different factors such as pancreatic and gut hormones, adipokines (leptin, apelin,…), neurotransmitters and nutrients (glucose, lipids,…). The sources of ROS production are multiple including NADPH oxidase, but also the mitochondria which is considered as the main ROS producer in the brain. ROS are considered as signaling molecules, but conversely impairment of this neuronal signaling ROS pathway contributes to alterations of autonomic nervous system and neuroendocrine function, leading to metabolic diseases such as obesity and type 2 diabetes. In this review we focus our attention on factors that are able to modulate hypothalamic ROS release in order to control food intake and energy metabolism, and whose deregulations could participate to the development of pathological conditions. This novel insight reveals an original mechanism in the hypothalamus that controls energy balance and identify hypothalamic ROS signaling as a potential therapeutic strategy to treat metabolic disorders.

  12. Metal-semiconductor phase transition of order arrays of VO2 nanocrystals

    Science.gov (United States)

    Lopez, Rene; Suh, Jae; Feldman, Leonard; Haglund, Richard

    2004-03-01

    The study of solid-state phase transitions at nanometer length scales provides new insights into the effects of material size on the mechanisms of structural transformations. Such research also opens the door to new applications, either because materials properties are modified as a function of particle size, or because the nanoparticles interact with a surrounding matrix material, or with each other. In this paper, we describe the formation of vanadium dioxide nanoparticles in silicon substrates by pulsed laser deposition of ion beam lithographically selected sites and thermal processing. We observe the collective behavior of 50 nm diameter VO2 oblate nanoparticles, 10 nm high, and ordered in square arrays with arbitrary lattice constant. The metal-semiconductor-transition of the VO2 precipitates shows different features in each lattice spacing substrate. The materials are characterized by electron microscopy, x-ray diffraction, Rutherford backscattering. The features of the phase transition are studied via infrared optical spectroscopy. Of particular interest are the enhanced scattering and the surface plasmon resonance when the particles reach the metallic state. This resonance amplifies the optical contrast in the range of near-infrared optical communication wavelengths and it is altered by the particle-particle coupling as in the case of noble metals. In addition the VO2 nanoparticles exhibit sharp transitions with up to 50 K of hysteresis, one of the largest values ever reported for this transition. The optical properties of the VO2 nanoarrays are correlated with the size of the precipitates and their inter-particle distance. Nonlinear and ultra fast optical measurements have shown that the transition is the fastest known solid-solid transformation. The VO2 nanoparticles show the same bulk property, transforming in times shorter than 150 fs. This makes them remarkable candidates for ultrafast optical and electronic switching applications.

  13. Effects of training status and exercise intensity on phase II VO2 kinetics.

    Science.gov (United States)

    Koppo, Katrien; Bouckaert, Jacques; Jones, Andrew M

    2004-02-01

    To test the hypotheses that: 1) the time constant for the fast component of .VO2 kinetics (tau1) at exercise onset would be faster in trained than in untrained subjects for both moderate and heavy exercise, and that 2) tau1 would become progressively slower in untrained subjects at higher power outputs but be invariant in trained subjects. Eight untrained subjects (.VO2peak: 42.9 +/- 5.1 mL.kg-1.min-1) and seven trained cyclists (.VO2peak: 66.6 +/- 2.5 mL.kg-1.min-1) completed square-wave transitions to power outputs requiring 60% and 80% of gas exchange threshold (GET), and 50% of the difference between GET and .VO2 peak (50%Delta) from a baseline of "unloaded" cycling. .VO2 was measured breath-by-breath and individual responses were modeled using nonlinear regression techniques. A repeated measures ANOVA revealed that the tau1 was significantly smaller (i.e., the kinetics were faster) in the trained compared with the untrained subjects and that tau1 became significantly greater (i.e., the kinetics were slowed) at higher power outputs both in the untrained (60%GET: 17.8 +/- 3.8 s, 80%GET: 21.5 +/- 6.6 s, and 50%Delta: 23.5 +/- 2.8 s) and the trained (60%GET: 8.9 +/- 1.3 s, 80%GET: 11.7 +/- 2.5 s, and 50%Delta: 15.2 +/- 2.0 s) subjects (P exercise intensity domain (recruitment of higher threshold motor units.

  14. Hydrothermal Synthesis of VO2 Polymorphs: Advantages, Challenges and Prospects for the Application of Energy Efficient Smart Windows.

    Science.gov (United States)

    Li, Ming; Magdassi, Shlomo; Gao, Yanfeng; Long, Yi

    2017-09-01

    Vanadium dioxide (VO 2 ) is a widely studied inorganic phase change material, which has a reversible phase transition from semiconducting monoclinic to metallic rutile phase at a critical temperature of τ c ≈ 68 °C. The abrupt decrease of infrared transmittance in the metallic phase makes VO 2 a potential candidate for thermochromic energy efficient windows to cut down building energy consumption. However, there are three long-standing issues that hindered its application in energy efficient windows: high τ c , low luminous transmittance (T lum ), and undesirable solar modulation ability (ΔT sol ). Many approaches, including nano-thermochromism, porous films, biomimetic surface reconstruction, gridded structures, antireflective overcoatings, etc, have been proposed to tackle these issues. The first approach-nano-thermochromism-which is to integrate VO 2 nanoparticles in a transparent matrix, outperforms the rest; while the thermochromic performance is determined by particle size, stoichiometry, and crystallinity. A hydrothermal method is the most common method to fabricate high-quality VO 2 nanoparticles, and has its own advantages of large-scale synthesis and precise phase control of VO 2 . This Review focuses on hydrothermal synthesis, physical properties of VO 2 polymorphs, and their transformation to thermochromic VO 2 (M), and discusses the advantages, challenges, and prospects of VO 2 (M) in energy-efficient smart windows application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Synthesis of vanadium oxides 5 wt.%VO2–MxOy by sol–gel process ...

    Indian Academy of Sciences (India)

    Experimental results indicated that the VO2–SiO2 catalysts .... crucible, which was supported by the beam of a balance in the oven. ... Epoxidation of cyclohexene on VO2–Mx Oy (M = Si, Al, Ti). 1189 ... tially amorphous nature of silica.

  16. Graphene-Nanowall-Decorated Carbon Felt with Excellent Electrochemical Activity Toward VO2+/VO2+ Couple for All Vanadium Redox Flow Battery.

    Science.gov (United States)

    Li, Wenyue; Zhang, Zhenyu; Tang, Yongbing; Bian, Haidong; Ng, Tsz-Wai; Zhang, Wenjun; Lee, Chun-Sing

    2016-04-01

    3D graphene-nanowall-decorated carbon felts (CF) are synthesized via an in situ microwave plasma enhanced chemical vapor deposition method and used as positive electrode for vanadium redox flow battery (VRFB). The carbon fibers in CF are successfully wrapped by vertically grown graphene nanowalls, which not only increase the electrode specific area, but also expose a high density of sharp graphene edges with good catalytic activities to the vanadium ions. As a result, the VRFB with this novel electrode shows three times higher reaction rate toward VO 2 + /VO 2+ redox couple and 11% increased energy efficiency over VRFB with an unmodified CF electrode. Moreover, this designed architecture shows excellent stability in the battery operation. After 100 charging-discharging cycles, the electrode not only shows no observable morphology change, it can also be reused in another battery and practical with the same performance. It is believed that this novel structure including the synthesis procedure will provide a new developing direction for the VRFB electrode.

  17. Synthesis of boron and nitrogen co-doped carbon nanofiber as efficient metal-free electrocatalyst for the VO"2"+/VO_2"+ Redox Reaction

    International Nuclear Information System (INIS)

    Shi, Lang; Liu, Suqin; He, Zhen; Yuan, Hao; Shen, Junxi

    2015-01-01

    Boron or nitrogen mono-doped carbon nanofiber (CNF), and boron, nitrogen co-doped CNF are intentionally prepared as positive electrodes in a vanadium redox flow battery (VRFB). The structures and electrochemical properties of the materials are investigated by Scanning electron microscopy, Raman spectroscopy, X-ray photoelectron spectroscopy, cyclic voltammetry and electrochemical impendence spectroscopy. The experimental results indicate that either B or N mono-doped CNF shown better electrochemical performance than untreated one. Interestingly, for the B and N co-doped CNF, the separated case exhibited an outstanding electrochemical activity better than either B or N mono-doped case, while the bonded case leading to a sharp drop in conductivity and shown poor electrochemical performances. These results demonstrated that not the total amount of incorporated B and N but how the B and N are incorporated into carbon nanostructures determines the catalytic activity toward VO"2"+/VO_2"+ reaction. Moreover, the individual mechanism of the nitrogen and boron containing functional groups act as active sites have been analyzed.

  18. Graphene‐Nanowall‐Decorated Carbon Felt with Excellent Electrochemical Activity Toward VO2 +/VO2+ Couple for All Vanadium Redox Flow Battery

    Science.gov (United States)

    Li, Wenyue; Zhang, Zhenyu; Bian, Haidong; Ng, Tsz‐Wai

    2015-01-01

    3D graphene‐nanowall‐decorated carbon felts (CF) are synthesized via an in situ microwave plasma enhanced chemical vapor deposition method and used as positive electrode for vanadium redox flow battery (VRFB). The carbon fibers in CF are successfully wrapped by vertically grown graphene nanowalls, which not only increase the electrode specific area, but also expose a high density of sharp graphene edges with good catalytic activities to the vanadium ions. As a result, the VRFB with this novel electrode shows three times higher reaction rate toward VO2 +/VO2+ redox couple and 11% increased energy efficiency over VRFB with an unmodified CF electrode. Moreover, this designed architecture shows excellent stability in the battery operation. After 100 charging–discharging cycles, the electrode not only shows no observable morphology change, it can also be reused in another battery and practical with the same performance. It is believed that this novel structure including the synthesis procedure will provide a new developing direction for the VRFB electrode. PMID:27774399

  19. Hypoxia, but not an electrolyte-imbalanced diet, reduces feed intake, growth and oxygen consumption in rainbow trout (Oncorhynchus mykiss)

    NARCIS (Netherlands)

    Magnoni, Leonardo J.; Eding, Ep; Leguen, Isabelle; Prunet, Patrick; Geurden, Inge; Ozório, Rodrigo O.A.; Schrama, Johan W.

    2018-01-01

    Oxygen limitation and dietary imbalances are key aspects influencing feed intake (FI) and growth performance in cultured fish. This study investigated the combined effects of hypoxia and dietary electrolyte balance on the growth performance, body composition and nutrient utilization in a rainbow

  20. Anomalous optical switching and thermal hysteresis during semiconductor-metal phase transition of VO2 films on Si substrate

    International Nuclear Information System (INIS)

    Leahu, G.; Li Voti, R.; Sibilia, C.; Bertolotti, M.

    2013-01-01

    We present a detailed infrared study of the semiconductor-to-metal transition (SMT) in a vanadium dioxide (VO 2 ) film deposited on silicon wafer. The VO 2 phase transition is studied in the mid-infrared region by analyzing the transmittance and the reflectance measurements, and the calculated emissivity. The reflectance has been measured in two configurations: from the side of the VO 2 film and from that of Si wafer. The results show a strong asymmetry between the emissivity in the two configurations, and the fact that the emissivity dynamic range from the silicon side is twice as large than that from the VO 2 side. The temperature behaviour of the emissivity during the SMT put into evidence the phenomenon of the anomalous absorption in VO 2 , which has been explained by applying the Maxwell Garnett effective medium approximation theory

  1. Effects of temperature and hypoxic stress on the oxygen ...

    African Journals Online (AJOL)

    The specific oxygen consumption rate (VO2lMb) of Labeo capensis, the freshwater mudsucker, was determined for small and large fish at winter (8°C) and summer (23°C) temperatures. VO2lMb was also determined during hypoxic conditions of the experimental water. It was found that VO2lMb does not differ substantially ...

  2. Morphology-control of VO2 (B) nanostructures in hydrothermal synthesis and their field emission properties

    International Nuclear Information System (INIS)

    Yin Haihong; Yu Ke; Zhang Zhengli; Zhu Ziqiang

    2011-01-01

    VO 2 (B) nanostructures were synthesized via a facile hydrothermal process using V 2 O 5 as source material and oxalic acid as reductant. Three nanostructures of nanorods, nanocarambolas and nanobundles were found existing in the products, and a continuous changing of morphology was found in the synthesis process, during which the proportion of these three types of nanostructures can be adjusted by altering the concentrations of oxalic acid. The microstructures were evaluated using X-ray diffraction and scanning and transmission electron microscopies, respectively. FE properties measurement of these three types of nanostructures showed that the nanobundles have the best field emission performance with a turn-on field of ∼1.4 V/μm and a threshold field of ∼5.38 V/μm. These characteristics make VO 2 (B) nanostructures a competitive cathode material in field emission devices.

  3. Complex Quasi-Two-Dimensional Crystalline Order Embedded in VO2 and Other Crystals

    Science.gov (United States)

    Lovorn, Timothy; Sarker, Sanjoy K.

    2017-07-01

    Metal oxides such as VO2 undergo structural transitions to low-symmetry phases characterized by intricate crystalline order, accompanied by rich electronic behavior. We derive a minimal ionic Hamiltonian based on symmetry and local energetics which describes structural transitions involving all four observed phases, in the correct order. An exact analysis shows that complexity results from the symmetry-induced constraints of the parent phase, which forces ionic displacements to form multiple interpenetrating groups using low-dimensional pathways and distant neighbors. Displacements within each group exhibit independent, quasi-two-dimensional order, which is frustrated and fragile. This selective ordering mechanism is not restricted to VO2 : it applies to other oxides that show similar complex order.

  4. Local Peltier-effect-induced reversible metal–insulator transition in VO2 nanowires

    International Nuclear Information System (INIS)

    Takami, Hidefumi; Kanki, Teruo; Tanaka, Hidekazu

    2016-01-01

    We report anomalous resistance leaps and drops in VO 2 nanowires with operating current density and direction, showing reversible and nonvolatile switching. This event is associated with the metal–insulator phase transition (MIT) of local nanodomains with coexistence states of metallic and insulating phases induced by thermoelectric cooling and heating effects. Because the interface of metal and insulator domains has much different Peltier coefficient, it is possible that a significant Peltier effect would be a source of the local MIT. This operation can be realized by one-dimensional domain configuration in VO 2 nanowires because one straight current path through the electronic domain-interface enables theoretical control of thermoelectric effects. This result will open a new method of reversible control of electronic states in correlated electron materials.

  5. VO2 kinetics and performance in soccer players after intense training and inactivity

    DEFF Research Database (Denmark)

    Christensen, Peter Møller; Krustrup, Peter; Gunnarsson, Thomas P.

    2011-01-01

    18 elite soccer players were, for a two-week period, assigned to a high intensity training group (HI, n=7) performing 10 training sessions mainly consisting of aerobic high intensity training (8×2 min) and speed endurance training (10-12×30-s sprints) or a training cessation group (TC, n=11......PURPOSE:: To examine the effects of a short-term period with intensified training or training cessation of trained soccer players on VO2 kinetics at 75% maximal aerobic speed (MAS), oxidative enzymes and performance in repeated high intensity exercise. METHODS:: After the last match of the season......) that refrained from training. RESULTS:: For TC, VO2 kinetics became slower (P...

  6. Eu-emission quenching by electron screening in VO2 thin films

    International Nuclear Information System (INIS)

    Liu, H.; Lysenko, S.; Rua, A.; Vikhnin, V.; Vasquez, O.; Fernandez, F.E.

    2006-01-01

    As a kind of phase transition functional material, Vanadium dioxide (VO 2 ) thin films deposited on fused quartz substrate were fabricated using pulsed laser deposition (PLD) technique. Europium was introduced for structure study. By laser excitation at 526 nm, VO 2 thin film undergoes a reversible and ultrafast phase transition from semiconductor to metallic state, which results in a change of optical properties. In fluorescence measurement, Eu emission was found severely quenched in all as-grown thin films. After annealing the sample in air, a red Eu-emission appeared. The emission spectrum is characterized by a pronounced twin peak, centered at 617 nm ( 5 D - 7 F 2 ), surrounded by a set of broad, but relatively weaker bands (emission from 5 D to 7 F j manifold). The emission lifetime increased when the sample annealed at higher temperature for longer time. Each spectral component is actually a doublet which is the spectral overlap of emissions from Eu 3+ situated in two sites with different configurations. One is a linear h-Eu 3+ -h, where h stands for holes. Another is a right-angle configuration of h-Eu 3+ -h with Eu 3+ in the corner. In as-grown VO 2 film, Eu 3+ ions can either substitute V 4+ , leaving a negative charge around (Eu 3+ -O) - , or substitute V 5+ , leaving two negative charges around (Eu 3+ -O) -- . Due to trapped electrons in a large radius state, it covers Eu 3+ V 4+ -V 5+ complexes. It suggests that the screening by degenerate electronic gas may result in switching off the Eu-related optical response for a wide spectral region, causing emission quenching in VO 2 films

  7. Crystal Structure and Spectroscopic Characterization of K8(VO)2O(SO4)6:

    DEFF Research Database (Denmark)

    Rasmussen, Søren Birk; Rasmussen, Rikke Christina; Fehrmann, Rasmus

    2003-01-01

    Red and yellow dichroistic crystals of a vanadium(V) compound, potassium (mu-oxo, di-mu-suifato)bis(oxodisulfato-vanadate), K-8(VO)(2)O(SO4)(6), have been obtained from the ternary catalytic model melt system K2S2O7-K2SO4-V2O5. By slow cooling of the melt from 420 to 355 degreesC, crystal growth...

  8. The highest velocity and the shortest duration permitting attainment of VO2max during running

    Directory of Open Access Journals (Sweden)

    Tiago Turnes

    2015-02-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2015v17n2p226   The severe-intensity domain has important applications for the prescription of running training and the elaboration of experimental designs. The objectives of this study were: 1 to investigate the validity of a previously proposed model to estimate the shortest exercise duration (TLOW and the highest velocity (VHIGH at which VO2max is reached during running, and 2 to evaluate the effects of aerobic training status on these variables. Eight runners and eight physically active subjects performed several treadmill running exercise tests to fatigue in order to mathematically estimate and to experimentally determine TLOW and VHIGH. The relationship between the time to achieve VO2max and time to exhaustion (Tlim was used to estimate TLOW. VHIGH was estimated using the critical velocity model. VHIGH was assumed to be the highest velocity at which VO2 was equal to or higher than the average VO2max minus one standard deviation. TLOW was defined as Tlim associated with VHIGH. Runners presented better aerobic fitness and higher VHIGH (22.2 ± 1.9 km.h-1 than active subjects (20.0 ± 2.1 km.h-1. However, TLOW did not differ between groups (runners: 101 ± 39 s; active subjects: 100 ± 35 s. TLOW and VHIGH were not well estimated by the model proposed, with high coefficients of variation (> 6% and a low correlation coefficient (r<0.70, a fact reducing the validity of the model. It was concluded that aerobic training status positively affected only VHIGH. Furthermore, the model proposed presented low validity to estimate the upper boundary of the severe-intensity domain (i.e., VHIGH, irrespective of the subjects’ training status.

  9. Light-induced ultrafast phase transitions in VO2 thin film

    International Nuclear Information System (INIS)

    Lysenko, S.; Rua, A.J.; Vikhnin, V.; Jimenez, J.; Fernandez, F.; Liu, H.

    2006-01-01

    Vanadium dioxide shows a passive and reversible change from a monoclinic insulator phase to a metallic tetragonal rutile structure when the sample temperature is close to and over 68 deg. C. As a kind of functional material, VO 2 thin films deposited on fused quartz substrates were successfully prepared by the pulsed laser deposition (PLD) technique. With laser illumination at 400 nm on the obtained films, the phase transition (PT) occurred. The observed light-induced PT was as fast as the laser pulse duration of 100 fs. Using a femtosecond laser system, the relaxation processes in VO 2 were studied by optical pump-probe spectroscopy. Upon a laser excitation an instantaneous response in the transient reflectivity and transmission was observed followed by a relatively longer relaxation process. The alteration is dependent on pump power. The change in reflectance reached a maximum value at a pump pulse energy between 7 and 14 mJ/cm 2 . The observed PT is associated with the optical interband transition in VO 2 thin film. It suggests that with a pump laser illuminating on the film, excitation from the d θ,ε - state of valence band to the unoccupied excited mixed d θ,ε -π* - state of the conduction band in the insulator phase occurs, followed by a resonant transition to an unoccupied excited mixed d θ,ε -π* - state of the metallic phase band

  10. Atomic Origins of Monoclinic-Tetragonal (Rutile) Phase Transition in Doped VO2 Nanowires.

    Science.gov (United States)

    Asayesh-Ardakani, Hasti; Nie, Anmin; Marley, Peter M; Zhu, Yihan; Phillips, Patrick J; Singh, Sujay; Mashayek, Farzad; Sambandamurthy, Ganapathy; Low, Ke-Bin; Klie, Robert F; Banerjee, Sarbajit; Odegard, Gregory M; Shahbazian-Yassar, Reza

    2015-11-11

    There has been long-standing interest in tuning the metal-insulator phase transition in vanadium dioxide (VO2) via the addition of chemical dopants. However, the underlying mechanisms by which doping elements regulate the phase transition in VO2 are poorly understood. Taking advantage of aberration-corrected scanning transmission electron microscopy, we reveal the atomistic origins by which tungsten (W) dopants influence the phase transition in single crystalline WxV1-xO2 nanowires. Our atomically resolved strain maps clearly show the localized strain normal to the (122̅) lattice planes of the low W-doped monoclinic structure (insulator). These strain maps demonstrate how anisotropic localized stress created by dopants in the monoclinic structure accelerates the phase transition and lead to relaxation of structure in tetragonal form. In contrast, the strain distribution in the high W-doped VO2 structure is relatively uniform as a result of transition to tetragonal (metallic) phase. The directional strain gradients are furthermore corroborated by density functional theory calculations that show the energetic consequences of distortions to the local structure. These findings pave the roadmap for lattice-stress engineering of the MIT behavior in strongly correlated materials for specific applications such as ultrafast electronic switches and electro-optical sensors.

  11. Electronic transport in VO2—Experimentally calibrated Boltzmann transport modeling

    International Nuclear Information System (INIS)

    Kinaci, Alper; Rosenmann, Daniel; Chan, Maria K. Y.; Kado, Motohisa; Ling, Chen; Zhu, Gaohua; Banerjee, Debasish

    2015-01-01

    Materials that undergo metal-insulator transitions (MITs) are under intense study, because the transition is scientifically fascinating and technologically promising for various applications. Among these materials, VO 2 has served as a prototype due to its favorable transition temperature. While the physical underpinnings of the transition have been heavily investigated experimentally and computationally, quantitative modeling of electronic transport in the two phases has yet to be undertaken. In this work, we establish a density-functional-theory (DFT)-based approach with Hubbard U correction (DFT + U) to model electronic transport properties in VO 2 in the semiconducting and metallic regimes, focusing on band transport using the Boltzmann transport equations. We synthesized high quality VO 2 films and measured the transport quantities across the transition, in order to calibrate the free parameters in the model. We find that the experimental calibration of the Hubbard correction term can efficiently and adequately model the metallic and semiconducting phases, allowing for further computational design of MIT materials for desirable transport properties

  12. o-Iminobenzosemiquinonate and o-imino-p-methylbenzosemiquinonate anion radicals coupled VO2+ stabilization.

    Science.gov (United States)

    Roy, Amit Saha; Saha, Pinaki; Adhikary, Nirmal Das; Ghosh, Prasanta

    2011-03-21

    The diamagnetic VO(2+)-iminobenzosemiquinonate anion radical (L(R)(IS)(•-), R = H, Me) complexes, (L(-))(VO(2+))(L(R)(IS)(•-)): (L(1)(-))(VO(2+))(L(H)(IS)(•-))•3/2MeOH (1•3/2MeOH), (L(2)(-))(VO(2+))(L(H)(IS)(•-)) (2), and (L(2)(-))(VO(2+))(L(Me)(IS)(•-))•1/2 L(Me)(AP) (3•1/2 L(Me)(AP)), incorporating tridentate monoanionic NNO-donor ligands {L = L(1)(-) or L(2)(-), L(1)H = (2-[(phenylpyridin-2-yl-methylene)amino]phenol; L(2)H = 1-(2-pyridylazo)-2-naphthol; L(H)(IS)(•-) = o-iminobenzosemiquinonate anion radical; L(Me)(IS)(•-) = o-imino-p-methylbenzosemiquinonate anion radical; and L(Me)(AP) = o-amino-p-methylphenol} have been isolated and characterized by elemental analyses, IR, mass, NMR, and UV-vis spectra, including the single-crystal X-ray structure determinations of 1•3/2MeOH and 3•1/2 L(Me)(AP). Complexes 1•3/2MeOH, 2, and 3•1/2 L(Me)(AP) absorb strongly in the visible region because of intraligand (IL) and ligand-to-metal charge transfers (LMCT). 1•3/2MeOH is luminescent (λ(ext), 333 nm; λ(em), 522, 553 nm) in frozen dichloromethane-toluene glass at 77 K due to π(diimine→)π(diimine)* transition. The V-O(phenolato) (cis to the V═O) lengths, 1.940(2) and 1.984(2) Å, respectively, in 1•3/2MeOH and 3•1/2 L(Me)(AP) are consistent with the VO(2+) description. The V-O(iminosemiquinonate) (trans to the V═O) lengths, 2.1324(19) in 1•3/2MeOH and 2.083(2) Å in 3•1/2 L(Me)(AP), are expectedly ∼0.20 Å longer due to the trans influence of the V═O bond. Because of the stronger affinity of the paramagnetic VO(2+) ion to the L(H)(IS)(•-) or L(Me)(IS)(•-), the V-N(iminosemiquinonate) lengths, 1.908(2) and 1.921(2) Å, respectively, in 1•3/2MeOH and 3•1/2 L(Me)(AP), are unexpectedly shorter. Density functional theory (DFT) calculations using B3LYP, B3PW91, and PBE1PBE functionals on 1 and 2 have established that the closed shell singlet (CSS) solutions (VO(3+)-amidophenolato (L(R)(AP)(2-)) coordination) of these

  13. EVALUATION AND COMPARISON OF VO2MAX ASSESSMENT MODELS IN HIGH SCHOOL STUDENTS

    Directory of Open Access Journals (Sweden)

    Bolboli Lotfali

    2013-04-01

    Full Text Available The purpose of this study was to evaluation and comparison of VO2max assessment models in students. Thirty students from high schools of Ardabil city were selected randomly and served as subjects in this study (age: 15.73±0.69 year, height: 169.46±8.1 cm, weight: 61.70±9.32 kg. Subjects were divided into two groups. In one group Rockport test was used to estimate their VO2 max and in other group Balk test was used for the same purpose. Also, the VO2max of both groups were examined by a standard treadmill test and the results were compared with the results of field tests. The one way of ANOVA and Tukey's post-hoc tests were used for data analysis (p>0/05. The results showed that there were significant differences between the results of the field tests and standard treadmill test (Bruce: 40.93±5.83 vs. Rockport: 58.71±2.73 and Balke: 52.09± 6.18. As a result of these findings it was concluded that the regression equations used in this study used is not suitable for 15-17 (yr boys and does not estimate their aerobic power correctly.

  14. Pengaruh metode latihan dan daya tahan otot tungkai terhadap hasil peningkatan kapasitas VO2Max pemain bola basket

    Directory of Open Access Journals (Sweden)

    Gregorius Pito Wahyu Prakoso

    2017-09-01

    Abstract This study aims to determine: (1 differences in the influence of methods of circuit training and interval method of training on the increase in capacity VO2Max basketball (2 the difference of increase in capacity VO2Max basketball resilient tall limb muscle and muscular endurance leg lower the increase in capacity VO2Max basketball, and (3 the interaction between exercise and limb muscle endurance against the increase in capacity VO2Max basketball. This research method used experiments with 2 x 2 factorial design study. The research sample of 20 children trained were taken with purposive sampling technique. Data were analyzed using analysis of variants (ANOVA. The results of this study indicate that: (1 there is no significant difference between exercise training method circuit training and training methods interval training against the increase in capacity VO2Max basketball, (2 There are no significant differences in increase in capacity VO2Max basketball among students who have the endurance of leg muscle and durability of  low leg muscle, (3 there is no interaction between the method of training (circuit training and interval training and leg muscle endurance against the increase in capacity VO2Max basketball.

  15. Tuning the work function of VO_2(1 0 0) surface by Ag adsorption and incorporation: Insights from first-principles calculations

    International Nuclear Information System (INIS)

    Chen, Lanli; Wang, Xiaofang; Shi, Siqi; Cui, Yuanyuan; Luo, Hongjie; Gao, Yanfeng

    2016-01-01

    Graphical abstract: - Highlights: • After adsorption, there is a charge transfer from Ag to VO_2(1 0 0) surface, which thus increases the electron concentration in VO_2 thin film. • Ag adsorption on VO_2(1 0 0) surface process is an exothermic chemical process, and the adsorption system is stable. • The work function can be tuned by Ag adsorption on and incorporation into the VO_2(1 0 0) surface, which in turn regulates the phase transition temperature of VO_2. - Abstract: VO_2 is an attractive material for application to thermochromic optoelectronic devices such as smart windows, and Ag/VO_2 double-layered structure can effectively decrease the phase transition temperature (T_c) of VO_2 thin film, which is very important for practical application of VO_2. Previous works has shown that the decrease in phase transition temperature (T_c) seems to be relevant with the work function of VO_2 in Ag/VO_2 double-layered thin film, although the underlying mechanism of tuning its T_c by Ag incorporation and adsorption on the VO_2(1 0 0) surface has been rarely investigated. Our first-principles calculations reveal that the adsorption of Ag atoms on the VO_2(1 0 0) surface rather than incorporation of Ag exhibits a lower work function, which is ascribed to an integrated effect of charge transfer from Ag to VO_2(1 0 0) surface and enhanced surface dipole moment. The results suggest that the decrease in work function of VO_2 with Ag adsorption favors the reduction in T_c. The current findings are helpful to understand the fundamental mechanism for yielding high-efficiency VO_2-based optoelectronic devices.

  16. Potential benefits of oxygen-enriched intake air in a vehicle powered by a spark-ignition engine

    Science.gov (United States)

    Ng, H. K.; Sekar, R. R.

    1994-04-01

    A production vehicle powered by a spark-ignition engine (3.1-L Chevrolet Lumina, model year 1990) was tested. The test used oxygen-enriched intake air containing 25 and 28% oxygen by volume to determine (1) if the vehicle would run without difficulties and (2) if emissions benefits would result. Standard Federal Test Procedure (FTP) emissions test cycles were run satisfactorily. Test results of catalytic converter-out emissions (emissions out of the converter) showed that both carbon monoxide and hydrocarbons were reduced significantly in all three phases of the emissions test cycle. Test results of engine-out emissions (emissions straight out of the engine, with the converter removed) showed that carbon monoxide was significantly reduced in the cold phase. All emission test results were compared with those for normal air (21% oxygen). The catalytic converter also had an improved carbon monoxide conversion efficiency under the oxygen-enriched-air conditions. Detailed results of hydrocarbon speciation indicated large reductions in 1,3-butadiene, formaldehyde, acetaldehyde, and benzene from the engine with the oxygen-enriched air. Catalytic converter-out ozone was reduced by 60% with 25%-oxygen-content air. Although NO(x) emissions increased significantly, both for engine-out and catalytic converter-out emissions, we anticipate that they can be ameliorated in the near future with new control technologies. The automotive industry currently is developing exhaust-gas control technologies for an oxidizing environment; these technologies should reduce NO(x) emissions more efficiently in vehicles that use oxygen-enriched intake air. On the basis of estimates made from current data, several production vehicles that had low NO(x) emissions could meet the 2004 Tier 2 emissions standards with 25%-oxygen-content air.

  17. VO2/TiO2 Nanosponges as Binder-Free Electrodes for High-Performance Supercapacitors

    Science.gov (United States)

    Hu, Chenchen; Xu, Henghui; Liu, Xiaoxiao; Zou, Feng; Qie, Long; Huang, Yunhui; Hu, Xianluo

    2015-11-01

    VO2/TiO2 nanosponges with easily tailored nanoarchitectures and composition were synthesized by electrostatic spray deposition as binder-free electrodes for supercapacitors. Benefiting from the unique interconnected pore network of the VO2/TiO2 electrodes and the synergistic effect of high-capacity VO2 and stable TiO2, the as-formed binder-free VO2/TiO2 electrode exhibits a high capacity of 86.2 mF cm-2 (~548 F g-1) and satisfactory cyclability with 84.3% retention after 1000 cycles. This work offers an effective and facile strategy for fabricating additive-free composites as high-performance electrodes for supercapacitors.

  18. Fourier transform infrared study of the phase transitions in (NH4)3VO2FO4

    Science.gov (United States)

    de Waal, D.; Heyns, A. M.

    1994-01-01

    Ammonium oxofluorovanadate compounds are known to show some potential as ferroelectric materials. The whole series of ammonium and sodium oxofluorovanadate compounds including Na3VO2F4 have already been prepared and investigated by means of various techniques including x-ray diffraction, EPR, and vibrational spectroscopy. It was established that the pure ammonium compound shows the two above mentioned transitions from phase A (below 200 K) to phase B (between 200 and 400 K) and phase C (above 400 K) while Na(NH4)2VO2F4 has only one transition from phase A to phase B around 400 K4. In the present study various aspects regarding the nature of the structures of (NH4)3VO2F3 and Na(NH4)2VO2F4 and its influence on the phase transitions have been investigated.

  19. VO2/TiO2 Nanosponges as Binder-Free Electrodes for High-Performance Supercapacitors.

    Science.gov (United States)

    Hu, Chenchen; Xu, Henghui; Liu, Xiaoxiao; Zou, Feng; Qie, Long; Huang, Yunhui; Hu, Xianluo

    2015-11-04

    VO2/TiO2 nanosponges with easily tailored nanoarchitectures and composition were synthesized by electrostatic spray deposition as binder-free electrodes for supercapacitors. Benefiting from the unique interconnected pore network of the VO2/TiO2 electrodes and the synergistic effect of high-capacity VO2 and stable TiO2, the as-formed binder-free VO2/TiO2 electrode exhibits a high capacity of 86.2 mF cm(-2) (~548 F g(-1)) and satisfactory cyclability with 84.3% retention after 1000 cycles. This work offers an effective and facile strategy for fabricating additive-free composites as high-performance electrodes for supercapacitors.

  20. A cost-effective process to prepare VO2 (M) powder and films with superior thermochromic properties

    International Nuclear Information System (INIS)

    Xiao, Xiudi; Zhang, Hua; Chai, Guanqi; Sun, Yaoming; Yang, Tao; Cheng, Haoliang; Chen, Lihua; Miao, Lei; Xu, Gang

    2014-01-01

    Graphical abstract: Combining codeposition and short time post annealing, VO 2 (M) with high quality and excellent phase transition performance is obtained. After mixing the VO 2 powder with acrylic resin, the composite films deposited on glass show superior visible transmission and solar modulation, which can be used as an excellent candidate of low cost smart window in energy saving field. - Highlights: • The VO 2 powder obtained by short time thermolysis method is high purity and crystallinity with superior phase transition performance. • The maximum decreasing efficiency of phase transition temperature is about −30 K/at% with w = 0.4 at%. • After mixing VO 2 powder with acrylic resin, the maximal visible transmission of the composite films is 48% and the transmission modulation at 2000 nm is 37.3% with phase transition temperature of 66.2 °C. • Though the phase transition performance is weakened by tungsten doping, the film prepared by 1.3 at% tungsten doped VO 2 still show superior transmission modulation about 26.4%, which means that it is a potential candidate as smart windows. - Abstract: VO 2 powder with superior phase transition performance was prepared by convenient thermolysis method. The results illustrated that VO 2 powder show high purity and crystallinity. VO 2 particles are transformed from cluster to quasi-sphere with the increase of annealing temperature. The DSC analysis proves that VO 2 show superior phase transition performance around 68 °C. The phase transition temperature can be reduced to 33.5 °C by 1.8 at% tungsten doping. The maximum decreasing efficiency of phase transition temperature is about −30 K/at% with w = 0.4 at%. After mixing VO 2 powder with acrylic resin, the maximal visible transmission of the composite thin films on glass is 48% and the transmission modulation at 2000 nm is 37.3% with phase transition temperature of 66.2 °C. Though the phase transition performance is weakened by tungsten doping, the film

  1. Relationship between level of forage intake, blood flow and oxygen consumption by splanchnic tissues of sheep fed a tropical grass forage.

    Science.gov (United States)

    Hentz, F; Kozloski, G V; Zeni, D; Brun, M V; Stefanello, S

    2017-02-01

    Four Polwarth castrated male sheep (42 ± 4.4 kg live weight (LW) surgically implanted with chronic indwelling catheters into the mesenteric, portal and hepatic veins, housed in metabolism cages and offered Cynodon sp. hay at rates (g of dry matter (DM)/kg LW) of 7, 14, 21 or ad libitum, were used in a 4 × 4 Latin square experiment to evaluate the effect of the level of forage intake on blood flow and oxygen consumption by the portal-drained viscera (PDV), liver and total splanchnic tissues (ST). The portal blood flow and the oxygen consumption by PDV linearly increased at increased organic matter (OM) intake. No effect of level of OM intake was obtained for the hepatic artery blood flow and oxygen consumption by liver. As a consequence, the level of OM intake only tended to directly affect hepatic blood flow and oxygen consumption by total ST. Oxygen consumption was linearly and positively related to blood flow across PDV, liver and total ST. The heat production by PDV and total ST, as proportion of metabolizable energy (ME) intake, decreased curvilinearly at increased ME intake. In conclusion, the oxygen consumption by PDV, but not by liver, was directly related to the level of forage intake by sheep. Moreover, when ingested at levels below maintenance, most of ME was spent as heat produced by ST. Journal of Animal Physiology and Animal Nutrition © 2016 Blackwell Verlag GmbH.

  2. Applicability of an Indirect VO2max Test: Its Association with the 400 Meters Freestyle Performance

    Directory of Open Access Journals (Sweden)

    Adalberto Veronese da Costa

    Full Text Available Abstract The aim of this study was to evaluate the VO2max using a previously validated indirect test for non-expert adult swimmers and to verify its connection with the 400 meters freestyle test. A total of 17 non-expert male swimmers (21.5 ± 3.12 years were evaluated. Body composition measurements included body weight (74 ± 9.41 kg, height (172.9 ± 5.21 cm and body fat percentage (15.2 ± 4.15 %. Two tests were conducted on different days; the 400 meters freestyle (400 MF and the Progressive Swim Test (PSwT, respectively. The participant's heart rate frequency before and after the test (BHR and AHR was analyzed, as well as the subjective perception of effort (RPE, the number of laps covered (NLP, and the time of test execution measured in minutes. Significant differences were identified in all variables (p - 0.60 was found between AHR and execution time (r > - 0.70, as well as between the VO2max estimated by the PSwT and the 400 MF performance test (r > - 0.70. The Bland-Altman Plot showed that the values discovered were within the established concordance limits of 95% (±1.96 SD. A negative correlation between a swimming test and a test that estimates the VO2max occurred, and the PSwT showed results of greater approximation of the aerobic power of non-expert swimmers. In conclusion, the PSwT is applicable for non-expert adult swimmers.

  3. SnO2@C@VO2 Composite Hollow Nanospheres as an Anode Material for Lithium-Ion Batteries.

    Science.gov (United States)

    Guo, Wenbin; Wang, Yong; Li, Qingyuan; Wang, Dongxia; Zhang, Fanchao; Yang, Yiqing; Yu, Yang

    2018-05-02

    Porous SnO 2 @C@VO 2 composite hollow nanospheres were ingeniously constructed through the combination of layer-by-layer deposition and redox reaction. Moreover, to optimize the electrochemical properties, SnO 2 @C@VO 2 composite hollow nanospheres with different contents of the external VO 2 were also studied. On the one hand, the elastic and conductive carbon as interlayer in the SnO 2 @C@VO 2 composite can not only buffer the huge volume variation during repetitive cycling but also effectively improve electronic conductivity and enhance the utilizing rate of SnO 2 and VO 2 with high theoretical capacity. On the other hand, hollow nanostructures of the composite can be consolidated by the multilayered nanocomponents, resulting in outstanding cyclic stability. In virtue of the above synergetic contribution from individual components, SnO 2 @C@VO 2 composite hollow nanospheres exhibit a large initial discharge capacity (1305.6 mAhg -1 ) and outstanding cyclic stability (765.1 mAhg -1 after 100 cycles). This design of composite hollow nanospheres may be extended to the synthesis of other nanomaterials for electrochemical energy storage.

  4. Dynamic Control of Light Emission Faster than the Lifetime Limit Using VO2 Phase-Change

    Science.gov (United States)

    2015-10-22

    2D colour plot of the calculated modulation amplitude of the MD contribution to Er3þ emission at 1.5mm upon the VO2 phase-change, as a function of TiO2...metallic state. Experimental spectra are shown in shaded red and blue colour , respectively, whereas theoretically predicted spectra are shown as black...model in Rakić et al.31. References 1. Loke, D. et al. Breaking the speed limits of phase-change memory . Science 336, 1566–1569 (2012). 2. Cavalleri

  5. Spectroscopic and optical properties of the VO2+ ion doped TeO2-TiO2-ZnO-Nb2O5 glass system

    Science.gov (United States)

    Swapna; Upender, G.; Sreenivasulu, V.; Prasad, M.

    2016-04-01

    Studies such as optical absorption, Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, Electron paramagnetic resonance (EPR) spectroscopy and Differential scanning calorimetry (DSC) were carried out on VO2+ ion doped TeO2-TiO2-ZnO-Nb2O5 glass system. Raman and FTIR spectra of the glasses revealed the presence of [TeO3], [TeO4] and [NbO6] structural units in the glass network. The Urbach energy (Δ E), cut-off wavelength (λ c ), optical band gap ( E opt ), optical basicity (Λ) and electron polarizability ( α) of the glasses were determined from optical absorption studies. The density ( ρ), molar volume ( V m ), oxygen molar volume ( V o ) and refractive index ( n) were also measured. Spin-Hamiltonian parameters were calculated from the EPR studies. When Nb2O5 was increased at the expense of ZnO, the density, optical band gap and Urbach energy of the glasses increased, and the electronic polarizability and optical basicity decreased. The EPR spectra clearly showed that vanadium was in the glass as VO2+ and occupied octahedral sites with tetrahedral compression. Spin-Hamiltonian parameters g‖ and g⊥ decreased as Nb2O5 content increased in the glass. The glass transition temperature ( T g ) also increased with increasing Nb2O5 content in the glass.

  6. THE RELATIONSHIP BETWEEN AEROBIC POWER AND REPEATED SPRINT ABILITY IN YOUNG SOCCER PLAYERS WITH DIFFERENT LEVELS OF VO2 MAX

    Directory of Open Access Journals (Sweden)

    Rostam Alizadeh

    2010-06-01

    Full Text Available In some team sports such as soccer which is interval, athletes need to prepare themselves immediatelyfor the next activity. Therefore it is very important to have enough information on characteristics of recovery phase and quick recovery to the first situation and to have the minimum speed reduction. The purpose of this study was to determine the relationship between aerobic power and repeated sprint ability (RSA or decrementindex in young soccer players in three different levels of Vo2max. Methods: For this reason 41 volunteers were divided in to three groups with different levels of Vo2max ml.kg-1.min-1 low 37.22 ± 2.3 (n= 18, age 17.1 ± 0.9 year, height 170.6 ± 0.76 cm, weight 67.1 ± 5.05 kg medium 46.46± 1.97 ml.kg-1.min-1 (n= 13, age 17.6± 0.76year, height 173.8 ± 4.84 cm, weight 65.9 ± 4.92 kg and high 55.63 ± 1.52 ml.kg-1.min-1 (n=10, age 17.4 ±0.69 year, height 177 ± 3.23 cm, weight 71.4 ± 3.94 kg. To determine Vo2max a graded exercise test until volitional exhaustion on treadmill was used, and also RAST was used to measure RSA. The lactate accumulation was measured before and after RSA protocol. Pearson's correlation was used to determine the correlation between the aerobic power and RSA. The results indicated that there are significant relationship between Vo2max anddecremental index in low Vo2max group (r= 0.86, p= 0.001, no significant relationship medium Vo2max group (r= 0.14, p= 0.63 and negative significant relationship in high Vo2max group (r= - 0.64, p= 0.04. There are no significant relationship between Lactate accumulation and decremental index in medium (r= 0.005, p= 0.98 and high Vo2max groups (r=0.27, p= 0.45. Discussion: It is possible that the recovery of inter muscular resources relates to aerobic ability, but there are other factors effective in RSA rather than Vo2max and Lactate accumulation. The current study showed a normal curved relationship between Vo2max and RSA.

  7. Exercise tolerance during VO2max testing is a multifactorial psychobiological phenomenon.

    Science.gov (United States)

    Midgley, Adrian W; Earle, Keith; McNaughton, Lars R; Siegler, Jason C; Clough, Peter; Earle, Fiona

    2017-01-01

    Fifty-nine men completed a VO 2max test and a questionnaire to establish reasons for test termination, perceived exercise reserve (difference between actual test duration and the duration the individual perceived could have been achieved if continued until physical limitation), and perception of verbal encouragement. Participants gave between 1 and 11 factors as reasons for test termination, including leg fatigue, various perceptions of physical discomfort, safety concerns, and achievement of spontaneously set goals. The two most common main reasons were leg fatigue and breathing discomfort, which were predicted by pre-to-post test changes in pulmonary function (p = 0.038) and explosive leg strength (p = 0.042; R 2  = 0.40). Median (interquartile range) perceived exercise reserve, was 45 (50) s. Two-thirds of participants viewed verbal encouragement positively, whereas one-third had a neutral or negative perception. This study highlights the complexity of exercise tolerance during VO 2max testing and more research should explore these novel findings.

  8. Nanoscale Engineering in VO2 Nanowires via Direct Electron Writing Process.

    Science.gov (United States)

    Zhang, Zhenhua; Guo, Hua; Ding, Wenqiang; Zhang, Bin; Lu, Yue; Ke, Xiaoxing; Liu, Weiwei; Chen, Furong; Sui, Manling

    2017-02-08

    Controlling phase transition in functional materials at nanoscale is not only of broad scientific interest but also important for practical applications in the fields of renewable energy, information storage, transducer, sensor, and so forth. As a model functional material, vanadium dioxide (VO 2 ) has its metal-insulator transition (MIT) usually at a sharp temperature around 68 °C. Here, we report a focused electron beam can directly lower down the transition temperature of a nanoarea to room temperature without prepatterning the VO 2 . This novel process is called radiolysis-assisted MIT (R-MIT). The electron beam irradiation fabricates a unique gradual MIT zone to several times of the beam size in which the temperature-dependent phase transition is achieved in an extended temperature range. The gradual transformation zone offers to precisely control the ratio of metal/insulator phases. This direct electron writing technique can open up an opportunity to precisely engineer nanodomains of diversified electronic properties in functional material-based devices.

  9. Determinants of time limit at velocity corresponding to VO2max in physically active individuals

    Directory of Open Access Journals (Sweden)

    Leonardo Gonçalves Ribeiro

    2008-07-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2008v10n1p69 The objective of the present study was to determine the relationship between time limit (Tlim at VO2Máx velocity (VVO2Máx and the variables VO2Máx, VVO2Máx, running economy (RE, ventilatory threshold (VT, strength test (9-10 maximum repetitions, velocity at maximal anaerobic running test (VMART, vertical jump test and body fat percentage. The sample was composed of 18 male volunteers, aged between 18 and 45 years old, non-athletes, but physically active. The study was carried out during fi ve visits, on non-consecutive days and at approximately the same time each day: visit 1 - signature of informed consent form, medical history, anthropometric assessment, aerobic power test and familiarization with Tlim test; visit 2 - RE test and Tlim test; visit 3 - familiarization with VMART test; visit 4 - familiarization with vertical jump and 9-10 maximum repetition tests and VMART test; visit 5 - vertical jump and 9-10 maximum repetition tests. Low (r = 0.220 to – 0.359 and non-signifi cant correlations (p = 0.281 to 0.935 were observed between Tlim and the selected variables, characterizing the low predictive value of Tlim for the sample studied. Thus, and because of the considerable inter-individual variability in Tlim, no variable was identifi ed that was capable of satisfactorily predicting Tlim.

  10. The Effect of a Moderately Low and High Carbohydrate Intake on Crossfit Performance.

    Science.gov (United States)

    Escobar, Kurt A; Morales, Jacobo; Vandusseldorp, Trisha A

    2016-01-01

    CrossFit is a metabolically demanding strength and conditioning method which performance may benefit from a carbohydrate (CHO)-rich diet. This study investigated the effect of three consecutive days of high CHO intake on CrossFit performance and corresponding metabolically -related variables in strength trained individuals. Eighteen subjects with a CHO intake of CrossFit workout. Oxygen consumption (VO 2 ), respiratory exchange ratio (RER), and blood lactate (BL) were also measured. Days 6-8, the CHO group increased CHO intake from CrossFit workouts followed by a day of rest prior to day 9. There was a significant increase in repetitions completed in both groups in day 9 (vs. means score of day 1 + 5) (p = 0.002), but no differences between C and CHO groups (p = 0.111). However, the CHO group displayed a 15.2 repetition increase (+10.9%) in day 9, compared to 5.7 (+4.2%) by the C group. VO 2 , RER, and BL were not influenced by the experimental intervention. Our results suggest that the CrossFit-embraced practice of moderately-low CHO diets may be adequate in CHO during short periods of training, however, given the noted trend, extended training periods may be effected.

  11. Hydrothermal encapsulation of VO2(A) nanorods in amorphous carbon by carbonization of glucose for energy storage devices.

    Science.gov (United States)

    Zheng, Jiqi; Zhang, Yifu; Wang, Qiushi; Jiang, Hanmei; Liu, Yanyan; Lv, Tianming; Meng, Changgong

    2018-01-02

    In recent decades, tremendous attention has been paid to the development of new electrode materials with high capacitance to meet the requirements of electrode materials in supercapacitors. Among vanadium oxides, VO 2 (A) has recently received increasing attention due to its unique layered structure, phase transformation and applications in Li-ion batteries. However, few studies have focused on the electrochemical properties of VO 2 (A) as electrochemical capacitors. Herein, we develop a facile hydrothermal method to prepare VO 2 (A)@C core-shell structured composites by carbonization of glucose in the presence of V 2 O 5 nanowires. The electrochemical properties of the VO 2 (A)@C core-shell composites are investigated as a supercapacitor electrode material for the first time; the composites show excellent pseudocapacitive behavior and display a specific capacitance as high as 179 F g -1 at 1 A g -1 . A flexible asymmetric supercapacitor device is fabricated using VO 2 (A)@C composites and activated carbon and delivers an excellent capacitance of 0.5 F cm -2 at a scan rate of 5 mV s -1 . Replacing the aqueous electrolyte with a LiCl/PVA gel electrolyte can efficiently improve the cycling performance to 85% retention after 1600 cycles. The good electrochemical performance of the composites indicates their high potential as electrode materials for supercapacitors.

  12. Enhanced Visible Transmittance of Thermochromic VO2 Thin Films by SiO2 Passivation Layer and Their Optical Characterization

    Directory of Open Access Journals (Sweden)

    Jung-Hoon Yu

    2016-07-01

    Full Text Available This paper presents the preparation of high-quality vanadium dioxide (VO2 thermochromic thin films with enhanced visible transmittance (Tvis via radio frequency (RF sputtering and plasma enhanced chemical vapor deposition (PECVD. VO2 thin films with high Tvis and excellent optical switching efficiency (Eos were successfully prepared by employing SiO2 as a passivation layer. After SiO2 deposition, the roughness of the films was decreased 2-fold and a denser structure was formed. These morphological changes corresponded to the results of optical characterization including the haze, reflectance and absorption spectra. In spite of SiO2 coating, the phase transition temperature (Tc of the prepared films was not affected. Compared with pristine VO2, the total layer thickness after SiO2 coating was 160 nm, which is an increase of 80 nm. Despite the thickness change, the VO2 thin films showed a higher Tvis value (λ 650 nm, 58% compared with the pristine samples (λ 650 nm, 43%. This enhancement of Tvis while maintaining high Eos is meaningful for VO2-based smart window applications.

  13. Mg-doped VO2 nanoparticles: hydrothermal synthesis, enhanced visible transmittance and decreased metal-insulator transition temperature.

    Science.gov (United States)

    Zhou, Jiadong; Gao, Yanfeng; Liu, Xinling; Chen, Zhang; Dai, Lei; Cao, Chuanxiang; Luo, Hongjie; Kanahira, Minoru; Sun, Chao; Yan, Liuming

    2013-05-28

    This paper reports the successful preparation of Mg-doped VO2 nanoparticles via hydrothermal synthesis. The metal-insulator transition temperature (T(c)) decreased by approximately 2 K per at% Mg. The Tc decreased to 54 °C with 7.0 at% dopant. The composite foils made from Mg-doped VO2 particles displayed excellent visible transmittance (up to 54.2%) and solar modulation ability (up to 10.6%). In addition, the absorption edge blue-shifted from 490 nm to 440 nm at a Mg content of 3.8 at%, representing a widened optical band gap from 2.0 eV for pure VO2 to 2.4 eV at 3.8 at% doping. As a result, the colour of the Mg-doped films was modified to increase their brightness and lighten the yellow colour over that of the undoped-VO2 film. A first principle calculation was conducted to understand how dopants affect the optical, Mott phase transition and structural properties of VO2.

  14. EPR and optical absorption studies of paramagnetic molecular ion (VO2+) in Lithium Sodium Acid Phthalate single crystal

    Science.gov (United States)

    Subbulakshmi, N.; Kumar, M. Saravana; Sheela, K. Juliet; Krishnan, S. Radha; Shanmugam, V. M.; Subramanian, P.

    2017-12-01

    Electron Paramagnetic Resonance (EPR) spectroscopic studies of VO2+ ions as paramagnetic impurity in Lithium Sodium Acid Phthalate (LiNaP) single crystal have been done at room temperature on X-Band microwave frequency. The lattice parameter values are obtained for the chosen system from Single crystal X-ray diffraction study. Among the number of hyperfine lines in the EPR spectra only two sets are reported from EPR data. The principal values of g and A tensors are evaluated for the two different VO2+ sites I and II. They possess the crystalline field around the VO2+ as orthorhombic. Site II VO2+ ion is identified as substitutional in place of Na1 location and the other site I is identified as interstitial location. For both sites in LiNaP, VO2+ are identified in octahedral coordination with tetragonal distortion as seen from the spin Hamiltonian parameter values. The ground state of vanadyl ion in the LiNaP single crystal is dxy. Using optical absorption data the octahedral and tetragonal parameters are calculated. By correlating EPR and optical data, the molecular orbital bonding parameters have been discussed for both sites.

  15. The acidic transformed nano-VO2 causes macrophage cell death by the induction of lysosomal membrane permeabilization and Ca2+ efflux

    Directory of Open Access Journals (Sweden)

    Shaohai Xu

    2015-01-01

    Full Text Available Because of its outstanding thermochromic characteristics and metal-insulator transition (MIT property, nano-vanadium dioxide (abbreviated as nano-VO2 or nVO2 has been applied widely in electrical/optical devices and design of intelligent window. However, the biological effect of nVO2 is not well understood, especially when affected by environmental factors or living organisms. For VO2 is an amphoteric oxide, we simulated pH's influence to nVO2’s physicochemical properties by exposure nVO2 in water of different pH values. We found that nVO2 transformed to a new product after exposure in acidic water for two weeks, as revealed by physicochemical characterization such as SEM, TEM, XRD, and DLS. This transformation product formed in acidic water was referred as (acidic transformed nVO2. Both pristine/untransformed and transformed nVO2 displayed no obvious toxicity to common epithelial cells; however, the acidic transformed nVO2 rapidly induced macrophage cell death. Further investigation demonstrated that transformed nVO2 caused macrophage apoptosis by the induction of Ca2+ efflux and the following mitochondrial membrane permeabilization (MMP process. And a more detailed time course study indicated that transformed nVO2 caused lysosomal membrane permeabilization (LMP at the earlier stage, indicating LMP could be chosen as an earlier and sensitive end point for nanotoxicological study. We conclude that although nVO2 displays no acute toxicity, its acidic transformation product induces macrophage apoptosis by the induction of LMP and Ca2+ efflux. This report suggests that the interplay with environmental factors or living organisms can results in physicochemical transformation of nanomaterials and the ensuing distinctive biological effects.

  16. Seasonal variations in VO2max, O2-cost, O2-deficit, and performance in elite cross-country skiers.

    Science.gov (United States)

    Losnegard, Thomas; Myklebust, Håvard; Spencer, Matt; Hallén, Jostein

    2013-07-01

    Long-term effects of training are important information for athletes, coaches, and scientists when associating changes in physiological indices with changes in performance. Therefore, this study monitored changes in aerobic and anaerobic capacities and performance in a group of elite cross-country skiers during a full sport season. Thirteen men (age, 23 ± 2 years; height, 182 ± 6 cm; body mass, 76 ± 8 kg; V2 roller ski skating VO2max, 79.3 ± 4.4 ml·kg·min or 6.0 ± 0.5 L·min) were tested during the early, middle, and late preparation phase: June (T1), August (T2), and October (T3); during the competition phase: January/February (T4); and after early precompetition phase: June (T5). O2-cost during submaximal efforts, V[Combining Dot Above]O2peak, accumulated oxygen deficit (ΣO2-deficit), and performance during a 1,000-m test were determined in the V2 ski skating technique on a roller ski treadmill. Subjects performed their training on an individual basis, and detailed training logs were categorized into different intensity zones and exercise modes. Total training volume was highest during the summer months (early preseason) and decreased toward and through the winter season, whereas the volume of high-intensity training increased (all p size; ES = 0.63-1.37, moderate to large, all p country skiers induced no significant changes in V[Combining Dot Above]O2peak but improved performance, O2-cost, and ΣO2-deficit.

  17. Why the Heyd-Scuseria-Ernzerhof hybrid functional description of VO2 phases is not correct

    KAUST Repository

    Grau-Crespo, Ricardo; Schwingenschlö gl, Udo; Wang, Hao

    2012-01-01

    In contrast with recent claims that the Heyd-Scuseria-Ernzerhof (HSE) screened hybrid functional can provide a good description of the electronic and magnetic structures of VO2 phases, we show here that the HSE lowest-energy solutions for both the low-temperature monoclinic (M1) phase and the high-temperature rutile (R) phase, which are obtained upon inclusion of spin polarization, are at odds with experimental observations. For the M1 phase the ground state is (but should not be) magnetic, while the ground state of the R phase, which is also spin polarized, is not (but should be) metallic. The energy difference between the low-temperature and high-temperature phases has strong discrepancies with the experimental latent heat.

  18. Why the Heyd-Scuseria-Ernzerhof hybrid functional description of VO2 phases is not correct

    KAUST Repository

    Grau-Crespo, Ricardo

    2012-08-06

    In contrast with recent claims that the Heyd-Scuseria-Ernzerhof (HSE) screened hybrid functional can provide a good description of the electronic and magnetic structures of VO2 phases, we show here that the HSE lowest-energy solutions for both the low-temperature monoclinic (M1) phase and the high-temperature rutile (R) phase, which are obtained upon inclusion of spin polarization, are at odds with experimental observations. For the M1 phase the ground state is (but should not be) magnetic, while the ground state of the R phase, which is also spin polarized, is not (but should be) metallic. The energy difference between the low-temperature and high-temperature phases has strong discrepancies with the experimental latent heat.

  19. Determinants of time limit at velocity corresponding to VO2max in physically active individuals

    Directory of Open Access Journals (Sweden)

    Jefferson da Silva Novaes

    2008-01-01

    Full Text Available The objective of the present study was to determine the relationship between time limit (Tlim at VO2Máx velocity (VVO2Máx and the variables VO2Máx, VVO2Máx, running economy (RE, ventilatory threshold (VT, strength test (9-10 maximum repetitions, velocity at maximal anaerobic running test (VMART, vertical jump test and body fat percentage. The sample was composed of 18 male volunteers, aged between 18 and 45 years old, non-athletes, but physically active. The study was carried out during fi ve visits, on non-consecutive days and at approximately the same time each day: visit 1 - signature of informed consent form, medical history, anthropometric assessment, aerobic power test and familiarization with Tlim test; visit 2 - RE test and Tlim test; visit 3 - familiarization with VMART test; visit 4 - familiarization with vertical jump and 9-10 maximum repetition tests and VMART test; visit 5 - vertical jump and 9-10 maximum repetition tests. Low (r = 0.220 to – 0.359 and non-significant correlations (p = 0.281 to 0.935 were observed between Tlim and the selected variables, characterizing the low predictive value of Tlim for the sample studied. Thus, and because of the considerable inter-individual variability in Tlim, no variable was identified that was capable of satisfactorily predicting Tlim. Resumo O objetivo do presente estudo foi determinar a relação do tempo limite (Tlim na velocidade do VO2Máx (VVO2Máx com as variáveis VO2Máx, VVO2Máx, economia de corrida (EC, limiar ventilatório (LV, força isotônica (determinada pelo teste de 9-10 RM, velocidade no teste máximo de corrida anaeróbica (VMART, impulsão vertical e percentual de gordura (%G . A amostra foi composta por 18 voluntários do sexo masculino, com idade entre 18 e 45 anos, não atletas, regularmente ativos. O estudo foi realizado em cinco visitas, em dias não consecutivos e aproximadamente no mesmo horário, compostas de: visita 1 - assinatura do termo de

  20. Study of substitution reactions of ligands in VO2+ complexes in toluene solutions by ESR method

    International Nuclear Information System (INIS)

    Lundkvist, R.; Panfilov, A.T.; Kalinichenko, N.B.; Marov, I.N.; AN SSSR, Moscow. Inst. Geokhimii i Analiticheskoj Khimii)

    1976-01-01

    Kinetics and equilibrium of stepwise substitution of ligands have been investigated at different temperatures for the complexes of oxovanadium (4) with salicylaldoxime, 8-oxyquinoline, acetylacetone, benzoylacetone, and tenoyltrifluoroacetone. The relative complexability of these ligands in toluene has been studied. The parameters of spin-Hamiltonian of EPR spectra of the VO 2+ complexes have been determined. The equilibrium constants, the rate constants, and activation energy have been found for the substitution reactions of ligands in the complexes VOA 2 : VOA 2 +HB=VOAB+HA; VOAB+HB=VOB 2 +HA, where HA and HB are the ligands with different donor atoms. The mixed complexes have been detected of the general formula VOAB, where HA is salicylaldoxime or 8-oxyquinoline and HB is β-diketone

  1. The ergogenic effect of recombinant human erythropoietin on VO2max depends on the severity of arterial hypoxemia

    DEFF Research Database (Denmark)

    Robach, Paul; Calbet, Jose A L; Thomsen, Jonas J

    2008-01-01

    degrees of acute hypoxia in eight rhEpo-treated subjects. Following prolonged rhEpo treatment, the gain in systemic VO(2)max observed in normoxia (6-7%) persisted during mild hypoxia (8% at inspired O(2) fraction (F(I)O(2)) of 0.173) and was even larger during moderate hypoxia (14-17% at F(I)O(2) = 0...... redistribution of cardiac output toward the exercising legs, whereas this advantageous effect disappeared during severe hypoxia, leaving augmented CaO(2) alone insufficient for improving peak leg O(2) delivery and VO(2). Finally, that VO(2)max was largely dependent on CaO(2) during moderate hypoxia but became...

  2. Excitations and possible bound states in the S = 1/2 alternating chain compound (VO)2P2O7

    International Nuclear Information System (INIS)

    Tennant, D.A.; Nagler, S.E.; Sales, B.C.

    1997-01-01

    Magnetic excitations in an array of (VO) 2 P 2 O 7 single crystals have been measured using inelastic neutron scattering. Until now, (VO) 2 P 2 O 7 has been thought of as a two-leg antiferromagnetic Heisenberg spin ladder with chains running in the a-direction. The present results show unequivocally that (VO) 2 P 2 O 7 is best described as an alternating spin-chain directed along the crystallographic b-direction. In addition to the expected magnon with magnetic zone-center energy gap Δ = 3.1 meV, a second excitation is observed at an energy just below 2Δ. The higher mode may be a triplet two-magnon bound state. Numerical results in support of bound modes are presented

  3. EPR and optical absorption studies of VO2+ doped L-alanine (C3H7NO2) single crystals

    International Nuclear Information System (INIS)

    Biyik, Recep

    2009-01-01

    VO 2+ doped L-alanine (C 3 H 7 NO 2 ) single crystals and powders are examined by electron paramagnetic resonance (EPR) and optical absorption spectroscopy. Three magnetically different sites are resolved from angular variations of L-alanine single crystal EPR spectra. In some specific orientations each VO 2+ line splits into three superhyperfine lines with intensities of 1:2:1 and maximum splitting value of 2.23 mT. The local symmetries of VO 2+ complex sites are nearly axial. The optical absorption spectra show three bands. Spin Hamiltonian parameters are measured and molecular orbital coefficients are calculated by correlating EPR and optical absorption data for the central vanadyl ion.

  4. Effects of prior heavy exercise on VO(2) kinetics during heavy exercise are related to changes in muscle activity.

    Science.gov (United States)

    Burnley, Mark; Doust, Jonathan H; Ball, Derek; Jones, Andrew M

    2002-07-01

    We hypothesized that the elevated primary O(2) uptake (VO(2)) amplitude during the second of two bouts of heavy cycle exercise would be accompanied by an increase in the integrated electromyogram (iEMG) measured from three leg muscles (gluteus maximus, vastus lateralis, and vastus medialis). Eight healthy men performed two 6-min bouts of heavy leg cycling (at 70% of the difference between the lactate threshold and peak VO(2)) separated by 12 min of recovery. The iEMG was measured throughout each exercise bout. The amplitude of the primary VO(2) response was increased after prior heavy leg exercise (from mean +/- SE 2.11 +/- 0.12 to 2.44 +/- 0.10 l/min, P exercise (491 +/- 108 vs. 604 +/- 151% increase above baseline values, P exercise is related to a greater recruitment of motor units at the onset of exercise.

  5. Plasma volume expansion does not increase maximal cardiac output or VO2 max in lowlanders acclimatized to altitude

    DEFF Research Database (Denmark)

    Calbet, José A L; Rådegran, Göran; Boushel, Robert Christopher

    2004-01-01

    liter of 6% dextran 70 (BV = 6.32 +/- 0.34 liters). PV expansion had no effect on Qmax, maximal O2 consumption (VO2), and exercise capacity. Despite maximal systemic O2 transport being reduced 19% due to hemodilution after PV expansion, whole body VO2 was maintained by greater systemic O2 extraction (P...... VO2 during exercise regardless of PV. Pulmonary ventilation, gas exchange, and acid-base balance were essentially unaffected by PV expansion. Sea......With altitude acclimatization, blood hemoglobin concentration increases while plasma volume (PV) and maximal cardiac output (Qmax) decrease. This investigation aimed to determine whether reduction of Qmax at altitude is due to low circulating blood volume (BV). Eight Danish lowlanders (3 females, 5...

  6. Sharpness and intensity modulation of the metal-insulator transition in ultrathin VO2 films by interfacial structure manipulation

    Science.gov (United States)

    McGee, Ryan; Goswami, Ankur; Pal, Soupitak; Schofield, Kalvin; Bukhari, Syed Asad Manzoor; Thundat, Thomas

    2018-03-01

    Vanadium dioxide (VO2) undergoes a structural transformation from monoclinic (insulator) to tetragonal (metallic) upon heating above 340 K, accompanied by abrupt changes to its electronic, optical, and mechanical properties. Not only is this transition scientifically intriguing, but there are also numerous applications in sensing, memory, and optoelectronics. Here we investigate the effect different substrates and the processing conditions have on the characteristics metal-insulator transition (MIT), and how the properties can be tuned for specific applications. VO2 thin films were grown on c -plane sapphire (0001) and p-type silicon by pulsed laser deposition. High-resolution x-ray diffraction along with transmission electron microscopy reveals textured epitaxial growth on sapphire by domain-matching epitaxy, while the presence of a native oxide layer on silicon prevented any preferential growth resulting in a polycrystalline film. An orientation relationship of (010)VO2|| (0001)Al 2O3 was established for VO2 grown on sapphire, while no such relationship was found for VO2 grown on silicon. Surface-energy minimization is the driving force behind grain growth, as the lowest energy VO2 plane grew on silicon, while on sapphire the desire for epitaxial growth was dominant. Polycrystallinity of films grown on silicon caused a weaker and less prominent MIT than observed on sapphire, whose MIT was higher in magnitude and steeper in slope. The position of the MIT was shown to depend on the competing effects of misfit strain and grain growth. Higher deposition temperatures caused an increase in the MIT, while compressive strain resulted in a decreased MIT.

  7. VO2 Kinetics in All-out Arm Stroke, Leg Kick and Whole Stroke Front Crawl 100-m Swimming.

    Science.gov (United States)

    Rodríguez, F A; Lätt, E; Jürimäe, J; Maestu, J; Purge, P; Rämson, R; Haljaste, K; Keskinen, K L; Jürimäe, T

    2016-03-01

    The VO2 response to extreme-intensity exercise and its relationship with sports performance are largely unexplored. This study investigated the pulmonary VO2 kinetics during all-out 100-m front crawl whole stroke swimming (S), arm stroke (A) and leg kick (L). 26 male and 10 female competitive swimmers performed an all-out S trial followed by A and L of equal duration in random order. Breath-by-breath VO2 was measured using a snorkel attached to a portable gas analyzer. Mean (±SD) primary component parameters and peak blood lactate (Lapeak) during S, A, and L were, respectively: time delay (s), 14.2 ± 4.7, 14.3 ± 4.5, 15.6 ± 5.1; amplitude (ml·kg(-1)·min(-1)), 46.8 ± 6.1, 37.3 ± 6.9, 41.0 ± 4.7; time constant (τ, s): 9.2 ± 3.2, 12.4 ± 4.7, 10.1 ± 3.2; Lapeak (mmol·l(-1)), 6.8 ± 3.1, 6.3 ± 2.5, 7.9 ± 2.8. During A and L respectively, 80% and 87% of amplitude in S was reached, whereas A+L were 68% greater than in S. 100-m performance was associated to shorter cardiodynamic phase and greater VO2 amplitude and Lapeak (accounting up to 61% of performance variance), but not to τ. We conclude that (i) VO2 gain was proportional to exercise intensity and muscle mass involved, (ii) kicking is metabolically less efficient, and (iii) the main limiting factor of peak VO2 appears to be O2 delivery and not muscle extraction. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Metal-Insulator Phase Transition in thin VO2 films: A Look from the Far Infrared Side

    DEFF Research Database (Denmark)

    Jepsen, Peter Uhd; Fischer, B. M.; Thoman, A.

    Vanadium dioxide (VO2) displays a well-known metal-insulator (MI) transition at atemperature of 68oC. The MI transition in VO2 has been studied extensively by a widerange of optical, electrical, structural, and magnetic measurements. In spite of this there isstill some controversy about the nature...... temperature hysteresis of the far-infrared transmission through thethin film with temperature. Interestingly the temperature-dependent transmissionamplitude shows a markedly different switching temperature than the transmission phase.This effect has not been observed before, and is very important...

  9. ARTICLES: Nonlinear interaction of infrared waves on a VO2 surface at a semiconductor-metal phase transition

    Science.gov (United States)

    Berger, N. K.; Zhukov, E. A.; Novokhatskiĭ, V. V.

    1984-04-01

    The use of a semiconductor-metal phase transition for wavefront reversal of laser radiation was proposed. An investigation was made of nonlinear reflection of CO2 laser radiation at a phase transition in VO2. A three-wave interaction on a VO2 surface was achieved using low-power cw and pulsed CO2 lasers. In the first case, the intensity reflection coefficient was 0.5% for a reference wave intensity of 0.9 W/cm2 and in the second case, it was 42% for a threshold reference wave energy density of 0.6-0.8 mJ/cm2.

  10. A COMPARISON BETWEEN VENTILATION AND HEART RATE AS INDICATOR OF OXYGEN UPTAKE DURING DIFFERENT INTENSITIES OF EXERCISE

    Directory of Open Access Journals (Sweden)

    Jacques Prioux

    2010-03-01

    Full Text Available The aim of this study is to compare the relation between ventilation (VE and oxygen uptake (VO2 [VO2=ƒ(VE] and between heart rate (HR and VO2 [VO2=ƒ(HR]. Each one of the subjects performed three types of activities of different intensities (walking without load, walking with load and intermittent work. VO2, VE, and HR were measured continuously by using indirect calorimetry and an electrocardiogram. Linear regressions and coefficients of determination (r² were calculated to compare the relation VO2 =ƒ(VE and VO2 =ƒ(HR for two different regroupings: by session duration (r²session and by subject (r²subject. Results showed that r²session of the relation VO2 =ƒ(VE were significantly higher than those of the relation VO2 =ƒ(HR for steady state activities (walking with or without load during 3 or 6 min, p < 0.01 and for activities without oxygen consumption steady state (walking with or without load during 1 min, p < 0.01 and intermittent work, p < 0.05. VE is more strongly correlated with VO2 than with HR. This is a very promising approach to develop a new method to estimate energy expenditure

  11. Effectiveness of High-Intensity Interval Training (HIT) and Continuous Endurance Training for VO2max Improvements: A Systematic Review and Meta-Analysis of Controlled Trials.

    Science.gov (United States)

    Milanović, Zoran; Sporiš, Goran; Weston, Matthew

    2015-10-01

    Enhancing cardiovascular fitness can lead to substantial health benefits. High-intensity interval training (HIT) is an efficient way to develop cardiovascular fitness, yet comparisons between this type of training and traditional endurance training are equivocal. Our objective was to meta-analyse the effects of endurance training and HIT on the maximal oxygen consumption (VO2max) of healthy, young to middle-aged adults. Six electronic databases were searched (MEDLINE, PubMed, SPORTDiscus, Web of Science, CINAHL and Google Scholar) for original research articles. A search was conducted and search terms included 'high intensity', 'HIT', 'sprint interval training', 'endurance training', 'peak oxygen uptake', and 'VO2max'. Inclusion criteria were controlled trials, healthy adults aged 18-45 years, training duration ≥2 weeks, VO2max assessed pre- and post-training. Twenty-eight studies met the inclusion criteria and were included in the meta-analysis. This resulted in 723 participants with a mean ± standard deviation (SD) age and initial fitness of 25.1 ± 5 years and 40.8 ± 7.9 mL·kg(-1)·min(-1), respectively. We made probabilistic magnitude-based inferences for meta-analysed effects based on standardised thresholds for small, moderate and large changes (0.2, 0.6 and 1.2, respectively) derived from between-subject SDs for baseline VO2max. The meta-analysed effect of endurance training on VO2max was a possibly large beneficial effect (4.9 mL·kg(-1)·min(-1); 95 % confidence limits ±1.4 mL·kg(-1)·min(-1)), when compared with no-exercise controls. A possibly moderate additional increase was observed for typically younger subjects (2.4 mL·kg(-1)·min(-1); ±2.1 mL·kg(-1)·min(-1)) and interventions of longer duration (2.2 mL·kg(-1)·min(-1); ±3.0 mL·kg(-1)·min(-1)), and a small additional improvement for subjects with lower baseline fitness (1.4 mL·kg(-1)·min(-1); ±2.0 mL·kg(-1)·min(-1)). When compared with no-exercise controls

  12. Voltage- and current-activated metal–insulator transition in VO2-based electrical switches: a lifetime operation analysis

    Directory of Open Access Journals (Sweden)

    Aurelian Crunteanu, Julien Givernaud, Jonathan Leroy, David Mardivirin, Corinne Champeaux, Jean-Christophe Orlianges, Alain Catherinot and Pierre Blondy

    2010-01-01

    Full Text Available Vanadium dioxide is an intensively studied material that undergoes a temperature-induced metal–insulator phase transition accompanied by a large change in electrical resistivity. Electrical switches based on this material show promising properties in terms of speed and broadband operation. The exploration of the failure behavior and reliability of such devices is very important in view of their integration in practical electronic circuits. We performed systematic lifetime investigations of two-terminal switches based on the electrical activation of the metal–insulator transition in VO2 thin films. The devices were integrated in coplanar microwave waveguides (CPWs in series configuration. We detected the evolution of a 10 GHz microwave signal transmitted through the CPW, modulated by the activation of the VO2 switches in both voltage- and current-controlled modes. We demonstrated enhanced lifetime operation of current-controlled VO2-based switching (more than 260 million cycles without failure compared with the voltage-activated mode (breakdown at around 16 million activation cycles. The evolution of the electrical self-oscillations of a VO2-based switch induced in the current-operated mode is a subtle indicator of the material properties modification and can be used to monitor its behavior under various external stresses in sensor applications.

  13. Phase transition in LiVO2 studied by near-edge x-ray-absorption spectroscopy

    NARCIS (Netherlands)

    Pen, HF; Tjeng, LH; Pellegrin, E; deGroot, FMF; Sawatzky, GA; vanVeenendaal, MA; Chen, CT

    1997-01-01

    We present temperature-dependent V-2p and O-1s x-ray-absorption spectra of LiVO2. The aim of this study is to monitor changes in electronic structure on going through the phase transition. The spectral changes turn out to be very small: the V-3d-O-2p hybridization does not change considerably, and

  14. Low-intensity training increases peak arm VO2 by enhancing both convective and diffusive O2 delivery

    DEFF Research Database (Denmark)

    Boushel, R; Ara, I; Gnaiger, E

    2014-01-01

    in prolonged low-intensity training of a small muscle group when the cardiac output capacity is not directly limiting. The purpose of this study was to investigate the relative roles of circulatory and muscle metabolic mechanisms by which prolonged low-intensity exercise training alters regional muscle VO2 ....

  15. Effect of blood haemoglobin concentration on V(O2,max) and cardiovascular function in lowlanders acclimatised to 5260 m

    DEFF Research Database (Denmark)

    Calbet, J A L; Rådegran, G; Boushel, Robert Christopher

    2002-01-01

    not alter peak CO. However, LBF and vascular conductance are higher at altitude when [Hb] is lowered to sea level values, with both relating closely to catecholamine and potassium concentrations. This suggests that the lack of effect of [Hb] on V(O(2),max) may involve reciprocal changes in LBF via local...

  16. Phase-field model of insulator-to-metal transition in VO2 under an electric field

    Science.gov (United States)

    Shi, Yin; Chen, Long-Qing

    2018-05-01

    The roles of an electric field and electronic doping in insulator-to-metal transitions are still not well understood. Here we formulated a phase-field model of insulator-to-metal transitions by taking into account both structural and electronic instabilities as well as free electrons and holes in VO2, a strongly correlated transition-metal oxide. Our phase-field simulations demonstrate that in a VO2 slab under a uniform electric field, an abrupt universal resistive transition occurs inside the supercooling region, in sharp contrast to the conventional Landau-Zener smooth electric breakdown. We also show that hole doping may decouple the structural and electronic phase transitions in VO2, leading to a metastable metallic monoclinic phase which could be stabilized through a geometrical confinement and the size effect. This work provides a general mesoscale thermodynamic framework for understanding the influences of electric field, electronic doping, and stress and strain on insulator-to-metal transitions and the corresponding mesoscale domain structure evolution in VO2 and related strongly correlated systems.

  17. Structural, thermal and optical properties of TeO2-ZnO-CdO-BaO glasses doped with VO(2+).

    Science.gov (United States)

    Sreenivasulu, V; Upender, G; Chandra Mouli, V; Prasad, M

    2015-09-05

    The glasses with composition 64TeO2-15ZnO-(20-x)CdO-xBaO-1V2O5 (0⩽x⩽20 mol%) were prepared by conventional melt quenching technique. X-ray diffraction analysis was used to confirm the amorphous nature of the glasses. The optical absorption studies revealed that the cut-off wavelength (λα) decreases while optical band gap energy (Eopt) and Urbach energy (ΔE) values increase with an increase of BaO content. Refractive index (n) evaluated from Eopt was found to decrease with an increase of BaO content. The physical parameters such as density (ρ), molar volume (Vm), oxygen packing density (OPD), optical basicity (Λ), molar refraction (Rm), and metallization criterion (M) evaluated and discussed. FTIR and Raman spectroscopic studies showed that the glass network consists of TeO4, TeO3+1/TeO3 and ZnO4 units as basic structural units. The glass transition temperature (Tg) of glass sample, onset crystallization temperature (To) and thermal stability ΔT were determined from Differential Scanning Calorimetry (DSC). Using electron paramagnetic resonance (EPR) spectra of vanadium glasses the spin Hamiltonian parameters and dipolar hyperfine coupling parameters of VO(2+) ions were calculated. It was found that V(4+) ions in these glasses exist as VO(2+) in octahedral coordination with a tetragonal distortion and have C4V symmetry with ground state dxy. Tetragonality (Δg∥/Δg⊥) of vanadium ion sites exhibited non-linear variation with BaO content. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Efeito da intensidade do exercício de corrida intermitente 30s:15s no tempo de manutenção no ou próximo do VO2max Effect of intensity of intermittent running exercise 30s:15s at the time maintenance at or near VO2max

    Directory of Open Access Journals (Sweden)

    Rafael Alves de Aguiar

    2013-03-01

    Full Text Available O presente estudo comparou o tempo mantido acima de 90% (t90VO2max e de 95% VO2max (t95VO2max em três diferentes intensidades de exercício. Após a realização de um teste incremental para determinar o VO2max, oito estudantes de educação física ativos (23 ± 3 anos executaram três sessões de exercícios intermitentes (100, 110 e 120% da velocidade do VO2max (vVO2max com razão esforço:recuperação de 30s:15s. O t95VO2max foi significantemente maior em 110%vVO2max (EI110% (218,1 ± 81,6 s quando comparado a 100%vVO2max (EI100% (91,9 ± 75,2s e a 120%vVO2max (EI120% (126,3 ± 29,4 s, porém sem diferença entre EI100% e EI120%. O t90VO2max somente apresentou diferença significante entre EI110% e EI120%. Portanto, conclui-se que durante exercício intermitente com razão 30s:15s, a intensidade de 110%vVO2max apresenta-se mais adequada para manter o VO2 próximo ou no VO2max por um tempo maior.The present study compared the time maintained above 90% (t90VO2max or 95% VO2max (t95VO2max in three different exercise intensities. After performing an incremental test to determine VO2max, eight physical education active students (23 ± 3 years performed three intermittent exercise sessions (100, 110 e 120% velocity of VO2max (vVO2max with ratio effort:recovery of 30s:15s. The t95%VO2max was significantly higher at 110%vVO2max (EI110% (218.1 ± 81.6s compared to 100% vVO2max (EI100% (91.9 ± 75.2s and 120%vVO2max (EI120% (126.3 ± 29.4s, but without differences between EI100% and EI120%. The t90%vVO2max was significantly different only between EI110% and 120%. Therefore, we conclude that during intermittent exercise with ratio 30s:15s, the intensity of 110%vVO2max appears more appropriate to maintain VO2max for a longer time.

  19. Effects of V2O3 buffer layers on sputtered VO2 smart windows: Improved thermochromic properties, tunable width of hysteresis loops and enhanced durability

    Science.gov (United States)

    Long, Shiwei; Cao, Xun; Sun, Guangyao; Li, Ning; Chang, Tianci; Shao, Zewei; Jin, Ping

    2018-05-01

    Vanadium dioxide (VO2) is one of the most well-known thermochromic materials, which exhibits a notable optical change from transparent to reflecting in the infrared region upon a metal-insulator phase transition. For practical applications, VO2 thin films should be in high crystalline quality to obtain a strong solar modulation ability (ΔTsol). Meanwhile, narrow hysteresis loops and robust ambient durability are also indispensable for sensitivity and long-lived utilization, respectively. In this work, a series of high-quality V2O3/VO2 bilayer structures were grown on quartz glass substrates by reactive magnetron sputtering. Basically, the bottom V2O3 acts as the buffer layer to improve the crystallinity of the top VO2, while the VO2 serves as the thermochromic layer to guarantee the solar modulation ability for energy-saving. We observed an obvious increase in ΔTsol of 76% (from 7.5% to 13.2%) for VO2 films after introducing V2O3 buffer layers. Simultaneously, a remarkable reduction by 79% (from 21.9 °C to 4.7 °C) in width of hysteresis loop was obtained when embedding 60 nm V2O3 buffer for 60 nm VO2. In addition, VO2 with non-stoichiometry of V2O3±x buffer demonstrates a broadening hysteresis loops width, which is derived from the lattice distortion caused by lattice imperfection. Finally, durability of VO2 has been significantly improved due to positive effects of V2O3 buffer layer. Our results lead to a comprehensive enhancement in crystallinity of VO2 and shed new light on the promotion of thermochromic property by homologous oxides for VO2.

  20. Modeling of thermal coupling in VO2-based oscillatory neural networks

    Science.gov (United States)

    Velichko, Andrey; Belyaev, Maksim; Putrolaynen, Vadim; Perminov, Valentin; Pergament, Alexander

    2018-01-01

    In this study, we have demonstrated the possibility of using the thermal coupling to control the dynamics of operation of coupled VO2 oscillators. Based on the example of a 'switch-microheater' pair, we have explored the synchronization and dissynchronization modes of a single oscillator with respect to an external harmonic heat impact. The features of changes in the spectra are shown, in particular, the effect of the natural frequency attraction to the affecting signal frequency and the self-oscillation noise reduction effects at synchronization. The time constant of the temperature effect for the considered system configuration is in the range 7-140 μs, which allows operation in the oscillation frequency range of up to ∼70 kHz. A model estimate of the minimum temperature sensitivity of the switch is δTswitch ∼ 0.2 K, and the effective action radius RTC of the switch-to-switch thermal coupling is not less than 25 μm. Nevertheless, as the simulation shows, the frequency range can be significantly extended up to the values of 1-30 GHz if using nanometer-scale switches (heaters). article>

  1. Hydrogen Treatment for Superparamagnetic VO2 Nanowires with Large Room-Temperature Magnetoresistance.

    Science.gov (United States)

    Li, Zejun; Guo, Yuqiao; Hu, Zhenpeng; Su, Jihu; Zhao, Jiyin; Wu, Junchi; Wu, Jiajing; Zhao, Yingcheng; Wu, Changzheng; Xie, Yi

    2016-07-04

    One-dimensional (1D) transition metal oxide (TMO) nanostructures are actively pursued in spintronic devices owing to their nontrivial d electron magnetism and confined electron transport pathways. However, for TMOs, the realization of 1D structures with long-range magnetic order to achieve a sensitive magnetoelectric response near room temperature has been a longstanding challenge. Herein, we exploit a chemical hydric effect to regulate the spin structure of 1D V-V atomic chains in monoclinic VO2 nanowires. Hydrogen treatment introduced V(3+) (3d(2) ) ions into the 1D zigzag V-V chains, triggering the formation of ferromagnetically coupled V(3+) -V(4+) dimers to produce 1D superparamagnetic chains and achieve large room-temperature negative magnetoresistance (-23.9 %, 300 K, 0.5 T). This approach offers new opportunities to regulate the spin structure of 1D nanostructures to control the intrinsic magnetoelectric properties of spintronic materials. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. F-doped VO2 nanoparticles for thermochromic energy-saving foils with modified color and enhanced solar-heat shielding ability.

    Science.gov (United States)

    Dai, Lei; Chen, Shi; Liu, Jianjun; Gao, Yanfeng; Zhou, Jiadong; Chen, Zhang; Cao, Chuanxiang; Luo, Hongjie; Kanehira, Minoru

    2013-07-28

    F-doped VO2 (M1) nanoparticles were prepared via one-pot hydrothermal synthesis. The F-doping can minimise the size of the VO2 (M1) nanoparticles, induce a homogeneous size distribution and effectively decrease the phase transition temperature to 35 °C at 2.93% F in VO2. VO2 smart glass foils obtained by casting these nanoparticles exhibit excellent thermochromism in the near-infrared region, which suggests that these foils can be used for energy-efficient glass. Compared to a pure VO2 foil, the 2.93% F-doped VO2 foil exhibits an increased solar-heat shielding ability (35.1%) and a modified comfortable colour, while still retaining an excellent solar modulation ability (10.7%) and an appropriate visible transmittance (48.7%). The F-doped VO2 foils are the first to simultaneously meet the requirements of a reduced phase transition temperature, diluted colour and excellent thermochromic properties, and these properties make the further improved F-doped VO2 foils suitable for commercial applications in energy efficient glass.

  3. Oxygen uptake kinetics during and after exercise are useful markers of coronary artery disease in patients with exercise electrocardiography suggesting myocardial ischemia

    International Nuclear Information System (INIS)

    Tajima, Akihiko; Ohkoshi, Nobuyuki; Kawara, Tokuhiro; Aizawa, Tadanori; Itoh, Haruki; Maeda, Tomoko; Osada, Naohiko; Omiya, Kazuto; Wasserman, K.

    2009-01-01

    The aim of the current study was to determine if the slowed exercise oxygen uptake (VO 2 ) kinetics, which is developed by myocardial ischemia, would be accompanied by delayed recovery VO 2 kinetics in patients with coronary artery disease (CAD). Thirty-seven patients with significant ST depression during treadmill exercise underwent cardiopulmonary exercise testing with cycle ergometer. Measurements performed are the ratios of change in increase in oxygen (O 2 ) uptake relative to increase in work rate (ΔVO 2 /ΔWR) across anaerobic threshold (AT) and 1 mm ST depression point (ST-dep), the time constants of VO 2 during recovery (T 1/2 VO 2 ), stress radio-isotope scintigraphy and coronary angiography. Patients were divided into CAD positive (CAD+) and CAD negative (CAD-) groups, based on coronary angiography. In CAD+, ΔVO 2 /ΔWR decreased above AT and ST-dep, in contrast to CAD- patients. The T 1/2 VO 2 in CAD+ (103.1±13.0 s) was greater than that of CAD- (76.5±8.7 s) and showed negative correlations to the ratios of ΔVO 2 /ΔWR across AT and ST-dep. These parameters improved in the patients who underwent coronary bypass surgery. Exercise and recovery VO 2 kinetics were slowed when myocardial ischemia was provoked by exercise. Measurement of exercise and recovery VO 2 kinetics improve the accuracy of the exercise electrocardiogram diagnosis of CAD. (author)

  4. Dietary calcium intake and Renin Angiotensin System polymorphisms alter the blood pressure response to aerobic exercise: a randomized control design

    Directory of Open Access Journals (Sweden)

    Tsongalis Gregory J

    2007-01-01

    Full Text Available Abstract Background Dietary calcium intake and the renin angiotensin system (RAS regulate blood pressure (BP by modulating calcium homeostasis. Despite similar BP regulatory effects, the influence of dietary calcium intake alone and combined with RAS polymorphisms on the BP response following acute aerobic exercise (i.e., postexercise hypotension has not been studied. Thus, we examined the effect of dietary calcium intake and selected RAS polymorphisms on postexercise hypotension. Methods Subjects were men (n = 50, 43.8 ± 1.3 yr with high BP (145.3 ± 1.5/85.9 ± 1.1 mm Hg. They completed three experiments: non-exercise control and two cycle bouts at 40% and 60% of maximal oxygen consumption (VO2max. Subjects provided 3 d food records on five protocol-specific occasions. Dietary calcium intake was averaged and categorized as low (1R A/C were analyzed with molecular methods. Genotypes were reduced from three to two: ACE II/ID and ACE DD; or AT1R AA and AT1R CC/AC. Repeated measure ANCOVA tested if BP differed among experiments, dietary calcium intake level and RAS polymorphisms. Results Systolic BP (SBP decreased 6 mm Hg after 40% and 60% VO2max compared to non-exercise control for 10 h with LowCa (p 2max versus non-exercise control for 10 h among ACE II/ID (6 mm Hg and AT1R AA (8 mm Hg; and by 8 mm Hg after 40% VO2max among ACE DD and AT1R CC/CA (p 2max compared to non-exercise control for 10 h (p 2max (p ≥ 0.05. Conclusion SBP decreased after exercise compared to non-exercise control among men with low but not high dietary calcium intake. Dietary calcium intake interacted with the ACE I/D and AT1R A/C polymorphisms to further modulate postexercise hypotension. Interactions among dietary calcium intake, exercise intensity and RAS polymorphisms account for some of the variability in the BP response to exercise.

  5. Changes in Running Economy, Respiratory Exchange Ratio and VO2max in Runners following a 10-day Altitude Training Camp.

    Science.gov (United States)

    Diebel, Sebastian R; Newhouse, Ian; Thompson, David S; Johnson, Vineet B K

    2017-01-01

    Running economy (RE) and VO 2 max are important predictors of endurance performance for elite and semi-elite endurance athletes, with RE being an appropriate predictor in a homogenous running population. Altitude training has been observed to change RE (mL.kg -1 .min -1 ), and VO 2 max due to alterations resulting from acclimatization. This study tracked changes in RE and VO 2 max before and after a 10-day altitude training camp at 1828 meters. VO 2 max, RE expressed calorically, and respiratory exchange ratio (RER), were measured below anaerobic threshold (AT) to observe differences between pre-and post-altitude training. Eight varsity cross-country runners between the ages of 18 and 22 years performed an incremental treadmill test, pre- and post-10-day altitude training. Paired samples t-tests were used to statistically analyze the data. Average RE (VO 2 mL.kg -1 .min -1 ) improved following altitude intervention ( M = 56.44 ± 4.28) compared to pre-altitude training (61.30 ± 7.56). These differences were statistically significant t ( 7 )= 2.71, p =.014. RE expressed as kcals.kg -1 .km -1 improved following altitude training (16.73 ± 2.96) compared to (18.44 ± 4.04) pre-altitude training and was statistically significant t( 7 ) =3.08, p = .008. RER taken during the last minute of steady-state was higher (0.97, ± .019) post-altitude training, compared to (0.90 ± .043) pre-altitude. These differences were statistically significant t ( 7 ) -3.62, p =.008. VO 2 max (mL.kg -1 .min -1 ) was lower in 6 out of 8 participants (63.91, ± 8.65) post-altitude compared to (69.90, ± 10.80) pre-altitude and was statistically significant t( 7 ) = 2.33, p =.026. The observed improvements in RE may be beneficial for endurance athletes competing and/or training at moderate altitudes near 1828 meters.

  6. Spanish genetic admixture is associated with larger V(O2) max decrement from sea level to 4338 m in Peruvian Quechua.

    Science.gov (United States)

    Brutsaert, Tom D; Parra, Esteban J; Shriver, Mark D; Gamboa, Alfredo; Palacios, Jose-Antonio; Rivera, Maria; Rodriguez, Ivette; León-Velarde, Fabiola

    2003-08-01

    Quechua in the Andes may be genetically adapted to altitude and able to resist decrements in maximal O2 consumption in hypoxia (DeltaVo2 max). This hypothesis was tested via repeated measures of Vo2 max (sea level vs. 4338 m) in 30 men of mixed Spanish and Quechua origins. Individual genetic admixture level (%Spanish ancestry) was estimated by using ancestry-informative DNA markers. Genetic admixture explained a significant proportion of the variability in DeltaVo2 max after control for covariate effects, including sea level Vo2 max and the decrement in arterial O2 saturation measured at Vo2 max (DeltaSpO2 max) (R2 for admixture and covariate effects approximately 0.80). The genetic effect reflected a main effect of admixture on DeltaVo2 max (P = 0.041) and an interaction between admixture and DeltaSpO2 max (P = 0.018). Admixture predicted DeltaVo2 max only in subjects with a large DeltaSpO2 max (P = 0.031). In such subjects, DeltaVo2 max was 12-18% larger in a subgroup of subjects with high vs. low Spanish ancestry, with least squares mean values (+/-SE) of 739 +/- 71 vs. 606 +/- 68 ml/min, respectively. A trend for interaction (P = 0.095) was also noted between admixture and the decrease in ventilatory threshold at 4338 m. As previously, admixture predicted DeltaVo2 max only in subjects with a large decrease in ventilatory threshold. These findings suggest that the genetic effect on DeltaVo2 max depends on a subject's aerobic fitness. Genetic effects may be more important (or easier to detect) in athletic subjects who are more likely to show gas-exchange impairment during exercise. The results of this study are consistent with the evolutionary hypothesis and point to a better gas-exchange system in Quechua.

  7. Effect of limb cooling on peripheral and global oxygen consumption in neonates.

    Science.gov (United States)

    Hassan, I A-A; Wickramasinghe, Y A; Spencer, S A

    2003-03-01

    To evaluate peripheral oxygen consumption (VO(2)) measurements using near infrared spectroscopy (NIRS) with arterial occlusion in healthy term neonates by studying the effect of limb cooling on peripheral and global VO(2). Twenty two healthy term neonates were studied. Peripheral VO(2) was measured by NIRS using arterial occlusion and measurement of the oxyhaemoglobin (HbO(2)) decrement slope. Global VO(2) was measured by open circuit calorimetry. Global and peripheral VO(2) was measured in each neonate before and after limb cooling. In 10 neonates, a fall in forearm temperature of 2.2 degrees C (mild cooling) decreased forearm VO(2) by 19.6% (p forearm temperature of 4 degrees C (moderate cooling) decreased forearm VO(2) by 34.7% (p cooling. The changes are more pronounced with moderate limb cooling when a concomitant rise in global VO(2) is observed. Change in peripheral temperature must be taken into consideration in the interpretation of peripheral VO(2) measurements in neonates.

  8. Thermal coupling and effect of subharmonic synchronization in a system of two VO2 based oscillators

    Science.gov (United States)

    Velichko, Andrey; Belyaev, Maksim; Putrolaynen, Vadim; Perminov, Valentin; Pergament, Alexander

    2018-03-01

    We explore a prototype of an oscillatory neural network (ONN) based on vanadium dioxide switching devices. The model system under study represents two oscillators based on thermally coupled VO2 switches. Numerical simulation shows that the effective action radius RTC of coupling depends both on the total energy released during switching and on the average power. It is experimentally and numerically proved that the temperature change ΔT commences almost synchronously with the released power peak and T-coupling reveals itself up to a frequency of about 10 kHz. For the studied switching structure configuration, the RTC value varies over a wide range from 4 to 45 μm, depending on the external circuit capacitance C and resistance Ri, but the variation of Ri is more promising from the practical viewpoint. In the case of a "weak" coupling, synchronization is accompanied by attraction effect and decrease of the main spectra harmonics width. In the case of a "strong" coupling, the number of effects increases, synchronization can occur on subharmonics resulting in multilevel stable synchronization of two oscillators. An advanced algorithm for synchronization efficiency and subharmonic ratio calculation is proposed. It is shown that of the two oscillators the leading one is that with a higher main frequency, and, in addition, the frequency stabilization effect is observed. Also, in the case of a strong thermal coupling, the limit of the supply current parameters, for which the oscillations exist, expands by ∼10%. The obtained results have a universal character and open up a new kind of coupling in ONNs, namely, T-coupling, which allows for easy transition from 2D to 3D integration. The effect of subharmonic synchronization hold promise for application in classification and pattern recognition.

  9. Bidirectional current triggering in planar devices based on serially connected VO2 thin films using 965 nm laser diode.

    Science.gov (United States)

    Kim, Jihoon; Park, Kyongsoo; Kim, Bong-Jun; Lee, Yong Wook

    2016-08-08

    By incorporating a 965 nm laser diode, the bidirectional current triggering of up to 30 mA was demonstrated in a two-terminal planar device based on serially connected vanadium dioxide (VO2) thin films grown by pulsed laser deposition. The bidirectional current triggering was realized by using the focused beams of laser pulses through the photo-thermally induced phase transition of VO2. The transient responses of laser-triggered currents were also investigated when laser pulses excited the device at a variety of pulse widths and repetition rates of up to 4.0 Hz. A switching contrast between off- and on-state currents was obtained as ~8333, and rising and falling times were measured as ~39 and ~29 ms, respectively, for 50 ms laser pulses.

  10. Thickness dependence of optical properties of VO2 thin films epitaxially grown on sapphire (0 0 0 1)

    International Nuclear Information System (INIS)

    Xu Gang; Jin Ping; Tazawa, Masato; Yoshimura, Kazuki

    2005-01-01

    Vanadium dioxide (VO 2 ) films were epitaxially grown on α-Al 2 O 3 (0 0 0 1) by rf reactive magnetron sputtering. The effects of film thickness ranging from 3 to 150 nm on optical properties were investigated. It revealed that the semiconductor--metal phase transition temperature considerably decreases as film thickness decreases, in particular for the film with thickness less than 10 nm. On the other hand, we found that the difference in visible transmittance between the two phases of VO 2 also varies with film thickness. For the films with thickness less than 50 nm, the semiconductor phase exhibits lower visible transmittance than its metallic phase, while for those with thickness larger than 50 nm the situation is reversed

  11. High-Impact Aerobic and Zumba Fitness on Increasing VO2MAX, Heart Rate Recovery and Skinfold Thickness

    Science.gov (United States)

    Suminar, T. J.; Kusnanik, N. W.; Wiriawan, O.

    2018-01-01

    Purpose of this study is to determine the significant effect of high-impact aerobics exercise, and Zumba fitness on increasing VO2Max, decreasing of heart rate recovery, and decreasing of skinfold thickness. A sample of this study is 30 members aerobics of student activity unit. Type of this study was quantitative by using a quasi-experimental design method. The design of this study used Matching-Only Design. Data were Analyzed by using the t test (paired t-test). The samples divided into three groups consisted of experimental group I, experimental group II, and control group. They were given a treatment for 8 weeks or 24 meeting. For the data, retrieval is done by MFT test, heart rate recovery test, and skinfold thickness test. Furthermore, the result was analyzed by using SPSS 21 series. In conclusion, significant effect of high-impact aerobics and Zumba fitness on increasing VO2Max, heart rate recovery, skinfold thickness.

  12. VO2 Thermochromic Films on Quartz Glass Substrate Grown by RF-Plasma-Assisted Oxide Molecular Beam Epitaxy

    Directory of Open Access Journals (Sweden)

    Dong Zhang

    2017-03-01

    Full Text Available Vanadium dioxide (VO2 thermochromic thin films with various thicknesses were grown on quartz glass substrates by radio frequency (RF-plasma assisted oxide molecular beam epitaxy (O-MBE. The crystal structure, morphology and chemical stoichiometry were investigated systemically by X-ray diffraction (XRD, atomic force microscopy (AFM, Raman spectroscopy and X-ray photoelectron spectroscopy (XPS analyses. An excellent reversible metal-to-insulator transition (MIT characteristics accompanied by an abrupt change in both electrical resistivity and optical infrared (IR transmittance was observed from the optimized sample. Remarkably, the transition temperature (TMIT deduced from the resistivity-temperature curve was reasonably consistent with that obtained from the temperature-dependent IR transmittance. Based on Raman measurement and XPS analyses, the observations were interpreted in terms of residual stresses and chemical stoichiometry. This achievement will be of great benefit for practical application of VO2-based smart windows.

  13. Effects of long or short duration stimulus during high-intensity interval training on physical performance, energy intake, and body composition.

    Science.gov (United States)

    Alves, Elaine Domingues; Salermo, Gabriela Pires; Panissa, Valéria Leme Gonçalves; Franchini, Emerson; Takito, Monica Yuri

    2017-08-01

    To compare the effects of 6 weeks of long or short high-intensity interval training (long- or short-HIIT) on body composition, hunger perception, food intake and rating of perceived exertion (RPE). Twenty previously untrained women (25±5 years) were randomly assigned to do a long-HIIT (n=10) or a short-HIIT (n=10). The long-HIIT group performed fifteen 1-min bouts at 90% of maximum heart rate (HRmax), interspersed by 30-sec active recovery (60% HRmax). The short-HIIT group performed forty-five 20-sec bouts at 90% of HRmax, interspersed by 10-sec active recovery (60% HRmax). The training for both groups was conducted 3 times a week for 6 weeks. All subjects performed the Astrand cycle ergometer test to estimate maximal oxygen consumption (VO 2max ) 1 week before and after the training period, as well as body composition, which was estimated through circumferences and skinfold thicknesses. For all training sessions, the heart rate, visual scale of hunger, internal load, and RPE were recorded. In the first and last week of training, subjects were asked to record a 24-hr food diary for 3 days. Both training induced significant pre to post decreases for fat mass, fat percentage, waist circumference, sum of seven skinfolds and RPE. As expected estimated, the VO 2max increased in both groups. There were no differences for hunger perception, energy intake, and body mass. Long and short-HIIT resulted in fat loss, without altering the energy intake.

  14. Allometric modelling of peak oxygen uptake in male soccer players of 8-18 years of age

    NARCIS (Netherlands)

    Valente-dos-Santos, Joao; Coelho-e-Silva, Manuel J.; Tavares, Oscar M.; Brito, Joao; Seabra, Andre; Rebelo, Antonio; Sherar, Lauren B.; Elferink-Gemser, Marije T.; Malina, Robert M.

    Background: Peak oxygen uptake (VO2peak) is routinely scaled as mL O-2 per kilogram body mass despite theoretical and statistical limitations of using ratios. Aim: To examine the contribution of maturity status and body size descriptors to ageassociated inter-individual variability in VO2peak and to

  15. Theoretical study of the local structures and the EPR parameters for RLNKB glasses with VO2+ and Cu2+ dopants

    Science.gov (United States)

    Ding, Chang-Chun; Wu, Shao-Yi; Wu, Li-Na; Zhang, Li-Juan; Peng, Li; Wu, Ming-He; Teng, Bao-Hua

    2018-02-01

    The electron paramagnetic resonance (EPR) parameters and local structures for impurities VO2+ and Cu2+ in RO-Li2O-Na2O-K2O-B2O3 (RLNKB; R = Zn, Mg, Sr and Ba) glasses are theoretically investigated by using the perturbation formulas of the EPR parameters for tetragonally compressed octahedral 3d1 and tetragonally elongated octahedral 3d9 clusters, respectively. The VO2+ and Cu2+ dopants are found to undergo the tetragonal compression (characterized by the negative relative distortion ratios ρ ≈ -3%, -0.98%, -1% and -0.8% for R = Zn, Mg, Sr and Ba) and elongation (characterized by the positive relative distortion ratios ρ ≈ 29%, 17%, 16% and 28%), respectively, due to the Jahn-Teller effect. Both dopants show similar overall decreasing trends of cubic field parameter Dq and covalency factor N with decreasing electronegativity of alkali earth cation R. The conventional optical basicities Λth and local optical basicities Λloc are calculated for both systems, and the local Λloc are higher for Cu2+ than for VO2+ in the same RLNKB glass, despite the opposite relationship for the conventional Λth. This point is supported by the weaker covalency or stronger ionicity for Cu2+ than VO2+ in the same RLNKB system, characterized by the larger N in the former. The above comparative analysis on the spectral and local structural properties would be helpful to understand structures and spectroscopic properties for the similar oxide glasses with transition-metal dopants of complementary electronic configurations.

  16. Ultrafast Dynamics of the VO2 Insulator-to-Metal Transition Observed by Nondegenerate Pump-Probe Spectroscopy

    Directory of Open Access Journals (Sweden)

    Haglund R. F.

    2013-03-01

    Full Text Available Non-degenerate pump (1.5 eV-probe (0.4 eV transmission spectroscopy on vanadium dioxide films grown on glass and three different sapphire substrates shows systematic variations with substrate that correlate with VO2 grain size and laser fluence. Temperature dependent measurements showed changes in the electronic response that is proportional to the metallic fraction.

  17. Carbon Quantum Dot Surface-Engineered VO2 Interwoven Nanowires: A Flexible Cathode Material for Lithium and Sodium Ion Batteries.

    Science.gov (United States)

    Balogun, Muhammad-Sadeeq; Luo, Yang; Lyu, Feiyi; Wang, Fuxin; Yang, Hao; Li, Haibo; Liang, Chaolun; Huang, Miao; Huang, Yongchao; Tong, Yexiang

    2016-04-20

    The use of electrode materials in their powdery form requires binders and conductive additives for the fabrication of the cells, which leads to unsatisfactory energy storage performance. Recently, a new strategy to design flexible, binder-, and additive-free three-dimensional electrodes with nanoscale surface engineering has been exploited in boosting the storage performance of electrode materials. In this paper, we design a new type of free-standing carbon quantum dot coated VO2 interwoven nanowires through a simple fabrication process and demonstrate its potential to be used as cathode material for lithium and sodium ion batteries. The versatile carbon quantum dots that are vastly flexible for surface engineering serve the function of protecting the nanowire surface and play an important role in the diffusion of electrons. Also, the three-dimensional carbon cloth coated with VO2 interwoven nanowires assisted in the diffusion of ions through the inner and the outer surface. With this unique architecture, the carbon quantum dot nanosurface engineered VO2 electrode exhibited capacities of 420 and 328 mAh g(-1) at current density rate of 0.3 C for lithium and sodium storage, respectively. This work serves as a milestone for the potential replacement of lithium ion batteries and next generation postbatteries.

  18. Effect of Omega-3 PUFAs Supplementation with Lifestyle Modification on Anthropometric Indices and Vo2 max in Overweight Women.

    Science.gov (United States)

    Haghravan, Simin; Keshavarz, Seyed Ali; Mazaheri, Reza; Alizadeh, Zahra; Mansournia, Mohammad Ali

    2016-05-01

    Despite the fact that the recommendations of counteracting obesity advocate for changing lifestyle and physical activity habits, the prevalence of obesity continues to rise. The aim of the study was to investigate the effect of omega-3 PUFAs supplementation with lifestyle modification on anthropometric indices and Vo2max in overweight women. Fifty overweight women aged between 20 to 45 years were recruited in this interventional study. Women randomly were divided into two experimental groups (n = 25). Group 1 received omega-3 supplement, aerobic exercise program, and a healthy diet education. Group 2 was similar to group 1, except in that patients received placebo instead of omega-3 capsules. Experimental and placebo group subjects were asked to take one supplementary capsule every day, for 8 weeks. Anthropometric indices were measured in the fourth and eighth weeks of the trial. The maximum aerobic capacity (Vo2max) was determined using a gas analysis device. The level of significance for comparing the results before and after the trial was considered at P study (P modification has positive effects on anthropometric indices and Vo2max in overweight women.

  19. Mesoscopic structural phase progression in photo-excited VO2 revealed by time-resolved x-ray diffraction microscopy

    Science.gov (United States)

    Zhu, Yi; Cai, Zhonghou; Chen, Pice; Zhang, Qingteng; Highland, Matthew J.; Jung, Il Woong; Walko, Donald A.; Dufresne, Eric M.; Jeong, Jaewoo; Samant, Mahesh G.; Parkin, Stuart S. P.; Freeland, John W.; Evans, Paul G.; Wen, Haidan

    2016-02-01

    Dynamical phase separation during a solid-solid phase transition poses a challenge for understanding the fundamental processes in correlated materials. Critical information underlying a phase transition, such as localized phase competition, is difficult to reveal by measurements that are spatially averaged over many phase separated regions. The ability to simultaneously track the spatial and temporal evolution of such systems is essential to understanding mesoscopic processes during a phase transition. Using state-of-the-art time-resolved hard x-ray diffraction microscopy, we directly visualize the structural phase progression in a VO2 film upon photoexcitation. Following a homogenous in-plane optical excitation, the phase transformation is initiated at discrete sites and completed by the growth of one lattice structure into the other, instead of a simultaneous isotropic lattice symmetry change. The time-dependent x-ray diffraction spatial maps show that the in-plane phase progression in laser-superheated VO2 is via a displacive lattice transformation as a result of relaxation from an excited monoclinic phase into a rutile phase. The speed of the phase front progression is quantitatively measured, and is faster than the process driven by in-plane thermal diffusion but slower than the sound speed in VO2. The direct visualization of localized structural changes in the time domain opens a new avenue to study mesoscopic processes in driven systems.

  20. Van der Waals MoS2/VO2 heterostructure junction with tunable rectifier behavior and efficient photoresponse.

    Science.gov (United States)

    Oliva, Nicoló; Casu, Emanuele Andrea; Yan, Chen; Krammer, Anna; Rosca, Teodor; Magrez, Arnaud; Stolichnov, Igor; Schueler, Andreas; Martin, Olivier J F; Ionescu, Adrian Mihai

    2017-10-27

    Junctions between n-type semiconductors of different electron affinity show rectification if the junction is abrupt enough. With the advent of 2D materials, we are able to realize thin van der Waals (vdW) heterostructures based on a large diversity of materials. In parallel, strongly correlated functional oxides have emerged, having the ability to show reversible insulator-to-metal (IMT) phase transition by collapsing their electronic bandgap under a certain external stimulus. Here, we report for the first time the electronic and optoelectronic characterization of ultra-thin n-n heterojunctions fabricated using deterministic assembly of multilayer molybdenum disulphide (MoS 2 ) on a phase transition material, vanadium dioxide (VO 2 ). The vdW MoS 2 /VO 2 heterojunction combines the excellent blocking capability of an n-n junction with a high conductivity in on-state, and it can be turned into a Schottky rectifier at high applied voltage or at temperatures higher than 68 °C, exploiting the metal state of VO 2 . We report tunable diode-like current rectification with a good diode ideality factor of 1.75 and excellent conductance swing of 120 mV/dec. Finally, we demonstrate unique tunable photosensitivity and excellent junction photoresponse in the 500/650 nm wavelength range.

  1. Flexible 3D Fe@VO2 core-shell mesh: A highly efficient and easy-recycling catalyst for the removal of organic dyes.

    Science.gov (United States)

    Li, Jing; Wang, Ruoqi; Su, Zhen; Zhang, Dandan; Li, Heping; Yan, Youwei

    2018-10-01

    Nowadays, it is extremely urgent to search for efficient and effective catalysts for water purification due to the severe worldwide water-contamination crises. Here, 3D Fe@VO 2 core-shell mesh, a highly efficient catalyst toward removal of organic dyes with excellent recycling ability in the dark is designed and developed for the first time. This novel core-shell structure is actually 304 stainless steel mesh coated by VO 2 , fabricated by an electrophoretic deposition method. In such a core-shell structure, Fe as the core allows much easier separation from the water, endowing the catalyst with a flexible property for easy recycling, while VO 2 as the shell is highly efficient in degradation of organic dyes with the addition of H 2 O 2 . More intriguingly, the 3D Fe@VO 2 core-shell mesh exhibits favorable performance across a wide pH range. The 3D Fe@VO 2 core-shell mesh can decompose organic dyes both in a light-free condition and under visible irradiation. The possible catalytic oxidation mechanism of Fe@VO 2 /H 2 O 2 system is also proposed in this work. Considering its facile fabrication, remarkable catalytic efficiency across a wide pH range, and easy recycling characteristic, the 3D Fe@VO 2 core-shell mesh is a newly developed high-performance catalyst for addressing the universal water crises. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Preparation, Characterization and Thermo-Chromic Properties of EVA/VO2 Laminate Films for Smart Window Applications and Energy Efficiency in Building

    Directory of Open Access Journals (Sweden)

    Onruthai Srirodpai

    2017-01-01

    Full Text Available Thermochromic films based on vanadium dioxide (VO2/ethylene vinyl acetate copolymer (EVA composite were developed. The monoclinic VO2 particles was firstly prepared via hydrothermal and calcination processes. The effects of hydrothermal time and tungsten doping agent on crystal structure and morphology of the calcined metal oxides were reported. After that, 1 wt % of the prepared VO2 powder was mixed with EVA compound, using two different mixing processes. It was found that mechanical properties of the EVA/VO2 films prepared by the melt process were superior to those of which prepared by the solution process. On the other hand, percentage visible light transmittance of the solution casted EVA/VO2 film was greater than that of the melt processed composite film. This was related to the different gel content of EVA rubber and state of dispersion and distribution of VO2 within the polymer matrix phase. Thermochromic behaviors and heat reflectance of the EVA/VO2 film were also verified. In overall, this study demonstrated that it was possible to develop a thermochromic film using the polymer composite approach. In this regard, the mixing condition was found to be one of the most important factors affecting morphology and thermo-mechanical properties of the films.

  3. Preparation and Characterization of Epitaxial VO2 Films on Sapphire Using Postepitaxial Topotaxy Route via Epitaxial V2O3 Films

    Science.gov (United States)

    Yamaguchi, Iwao; Manabe, Takaaki; Tsuchiya, Tetsuo; Nakajima, Tomohiko; Sohma, Mitsugu; Kumagai, Toshiya

    2008-02-01

    Epitaxial VO2 films were prepared on the C-planes of α-Al2O3 substrates by a metal organic deposition (MOD) process. It was difficult to obtain the single phase of (010)M-oriented VO2 films, in which the subscript M refers to the monoclinic indices, by the heat treatment of amorphous precursor films in the VO2-stable region after the pyrolysis of the coating solution. The product films consisted of discontinuous circular grains of 1-2 µm size on the substrate surface. Therefore, we prepared the (010)M-oriented epitaxial VO2 films using postepitaxial topotaxy (PET), that is, topotactic oxidation of (0001)-oriented epitaxial V2O3 films. First, epitaxial V2O3(0001) films were obtained by MOD starting with a vanadium naphthenate solution. Second, the epitaxial V2O3(0001) films were topotactically oxidized at 500 °C in an Ar-O2 gas mixture with pO2 = 10-4 atm to obtain (010)M-oriented epitaxial VO2 films. The epitaxial relationships were VO2(010)M ∥ α-Al2O3(0001) and VO2[100]M ∥ α-Al2O3[0110], [1010], [1100]. The VO2(010)M films exhibited metal-semiconductor transitions with hysteresis loops at 60-80 °C. The resistivity change before and after the transition of the VO2(010)M film oxidized for 6 h was three orders of magnitude.

  4. X-ray absorption spectroscopy of single-crystalline (VO)2P2O7: Electronic structure and possible exchange paths

    International Nuclear Information System (INIS)

    Gerhold, S.; Nu''cker, N.; Kuntscher, C. A.; Schuppler, S.; Stadler, S.; Idzerda, Y. U.; Prokofiev, A. V.; Bu''llesfeld, F.; Assmus, W.

    2001-01-01

    Using polarization-dependent V2p and O1s near-edge x-ray absorption spectroscopy, we studied the unoccupied electronic structure of single-crystalline (VO) 2 P 2 O 7 . It is highly anisotropic, and shows similarities to vanadium oxides like VO 2 and V 2 O 5 at the V2p edge and at the O1s threshold. The contributions from V-O and P-O orbitals could be identified. The results rule out the spin ladder model for the magnetic behavior of (VO) 2 P 2 O 7 , but are consistent with the alternating chain scenario

  5. Análise do consumo de oxigênio, freqüência cardíaca e dispêndio energético, durante as aulas do Jump Fit Análisis del consumo de oxígeno, frecuencia cardiaca y dispendio energético en las clases de Jump Fit Analysis of the oxygen intake, cardiac frequency and energetic expenditure during Jump Fit lessons

    Directory of Open Access Journals (Sweden)

    Elen Furtado

    2004-10-01

    identificar y evaluar el comportamiento de las variables funcionales, como: frecuencia cardiaca (FC, consumo de oxígeno (VO2, producción de dióxido de carbono (VCO2, cuociente respiratorio (QR, equivalente metabólico (MET y dispendio energético a través de la medición por espirometría de la rutina de una clase de Jump Fit. Las pruebas se realizaron en cuatro visitas por 10 mujeres que practican Jump Fit, con edad de 26,8 años (± 7,2, masa corporal de 57,6kg (± 6,8, altura de 162,2cm (± 3,9. La evaluación espirométrica de las diversas etapas de la clase reveló los siguientes resultados promedios: FC de 160,3bpm (± 8,9, VO2 de 1,59L.min-1 (± 0,45, QR 0,87 (± 0,10 y dispendio energético total 386,4kcal (± 13,8. El promedio de intensidad de la clase de Jump Fit correspondió al 75% (± 7,7 del VO2máximo. Para el análisis del comportamiento de las variables metabólicas en las distintas etapas de las clases se utilizó la ANOVA para medidas repetidas, con verificación de Bonferroni. Se empleó la prueba t para determinar se hubo diferencia entre las respuestas funcionales en las fases de reposo y del EPOC. Se adoptó el nivel de significancia de p Jump Fit lessons further the improvement of the general physical fitness through choreographies performed on an elastic surface with rhythm and movements variation with intervals and low impact. However, not much is known about the actual energetic expenditure and the behavior of the metabolic variables related to Jump Fit lessons. The objective of this study was to identify and to evaluate the behavior of the functional variables such as: heart rate (HR, oxygen intake (VO2, metabolic equivalent (MET and energetic expenditure through routine spirometry measurement of a Jump Fit lesson. The tests were performed in four visits by 10 women who practice Jump Fit with age of 26.8 (± 7.2, body mass of 57.6 kg (± 6.8 and height of 162.2 cm (± 3.9. The spirometric evaluation of the several stages of the lesson revealed

  6. Facile and Low-Temperature Fabrication of Thermochromic Cr2O3/VO2 Smart Coatings: Enhanced Solar Modulation Ability, High Luminous Transmittance and UV-Shielding Function.

    Science.gov (United States)

    Chang, Tianci; Cao, Xun; Li, Ning; Long, Shiwei; Gao, Xiang; Dedon, Liv R; Sun, Guangyao; Luo, Hongjie; Jin, Ping

    2017-08-09

    In the pursuit of energy efficient materials, vanadium dioxide (VO 2 ) based smart coatings have gained much attention in recent years. For smart window applications, VO 2 thin films should be fabricated at low temperature to reduce the cost in commercial fabrication and solve compatibility problems. Meanwhile, thermochromic performance with high luminous transmittance and solar modulation ability, as well as effective UV shielding function has become the most important developing strategy for ideal smart windows. In this work, facile Cr 2 O 3 /VO 2 bilayer coatings on quartz glasses were designed and fabricated by magnetron sputtering at low temperatures ranging from 250 to 350 °C as compared with typical high growth temperatures (>450 °C). The bottom Cr 2 O 3 layer not only provides a structural template for the growth of VO 2 (R), but also serves as an antireflection layer for improving the luminous transmittance. It was found that the deposition of Cr 2 O 3 layer resulted in a dramatic enhancement of the solar modulation ability (56.4%) and improvement of luminous transmittance (26.4%) when compared to single-layer VO 2 coating. According to optical measurements, the Cr 2 O 3 /VO 2 bilayer structure exhibits excellent optical performances with an enhanced solar modulation ability (ΔT sol = 12.2%) and a high luminous transmittance (T lum,lt = 46.0%), which makes a good balance between ΔT sol and T lum for smart windows applications. As for UV-shielding properties, more than 95.8% UV radiation (250-400 nm) can be blocked out by the Cr 2 O 3 /VO 2 structure. In addition, the visualized energy-efficient effect was modeled by heating a beaker of water using infrared imaging method with/without a Cr 2 O 3 /VO 2 coating glass.

  7. Use of ZnO as antireflective, protective, antibacterial, and biocompatible multifunction nanolayer of thermochromic VO2 nanofilm for intelligent windows

    International Nuclear Information System (INIS)

    Zhou, Huaijuan; Li, Jinhua; Bao, Shanhu; Li, Jian; Liu, Xuanyong; Jin, Ping

    2016-01-01

    Graphical abstract: - Highlights: • A multifunctional VO 2 /ZnO bilayer film is designed and deposited by magnetron sputtering apparatus. • The ZnO top layer can enhance the antireflective, antioxidative and anti-corrosion functions of the VO 2 film. • The ZnO top layer can endow VO 2 film with excellent antibacterial performance. • The ZnO top layer can attenuate the cytotoxicity of VO 2 thin film. - Abstract: A multifunctional VO 2 /ZnO bilayer film is designed and deposited by magnetron sputtering apparatus. The integration of the antireflective, antioxidative and anti-corrosion functions, and antibacterial performance makes the heterostructure film a promising candidate in the energy-saving smart window. The ZnO thin film as the antireflection layer can markedly boost the solar regulation efficiency (ΔT sol ) from 7.7% to 12.2% and possesses excellent luminous transmittance (T lum-L = 50.3%) in the low-temperature semiconductor phase. The ZnO layer as the protection barrier can not only protect VO 2 thin film from oxidation to much toxic V 2 O 5 , but also decrease the release of V ions. Besides, the synergistic effect of releasing killing by Zn 2+ ions and contact killing by ZnO NPs makes ZnO thin film an outstanding antibacterial coating. In terms of the biological safety, ZnO coating with appropriate film thickness can effectively attenuate the cytotoxicity of VO 2 on human HIBEpiC cells. We hope this work can provide new insights for better designing of novel multifunctional VO 2 -based intelligent energy-saving windows.

  8. Effects of exercise and group counselling on body composition and VO2max in overweight women with polycystic ovary syndrome.

    Science.gov (United States)

    Roessler, Kirsten K; Birkebaek, Camilla; Ravn, Pernille; Andersen, Marianne S; Glintborg, Dorte

    2013-03-01

    Polycystic ovary syndrome (PCOS) is often associated with an increased waist circumference and with lower cardio-respiratory fitness as a consequence of obesity, which may be improved by physical activity. To investigate the effect of high-intensity aerobic training combined with group counselling sessions on anthropometry and cardio-respiratory fitness in women with PCOS. Seventeen sedentary, overweight women with PCOS were randomized in a cross-over design to 16 weeks of intervention: eight weeks high-intensity aerobic exercise was followed by eight weeks of group counselling (n = 8) or vice versa (n = 9). Fourteen of the women completed the tests. Waist circumference, body mass index and maximal aerobic capacity (VO(2max) ) were measured at baseline, cross-over and post-intervention. There was a decrease in waist circumference (119.9 vs. 106.5 cm) and body mass index (34.9 vs. 34.4 kg/m(2) ) and an increase in VO(2max) (2554.9 vs. 2807.9 mL/min) during the intervention period (t = 16 weeks, n = 14), all p group which started with group counselling (2.9 vs. 0.6 kg, t = 16 weeks, n = 14, p = 0.055). Exercise in groups followed by counselling or vice versa had beneficial effects on waist circumference, weight, and VO(2max) in women with PCOS. Future studies should examine possible beneficial effects of combined group counselling and exercise on weight loss and adherence to exercise protocols among women with PCOS. © 2013 The Authors Acta Obstetricia et Gynecologica Scandinavica © 2013 Nordic Federation of Societies of Obstetrics and Gynecology.

  9. Augmentation of thermoelectric performance of VO2 thin films irradiated by 200 MeV Ag9+-ions

    International Nuclear Information System (INIS)

    Khan, G.R.; Kandasami, A.; Bhat, B.A.

    2016-01-01

    Swift Heavy Ion (SHI) irradiation with 200 MeV Ag 9+ -ion beam at ion fluences of 1E11, 5E11, 1E12, and 5E12 for tuning of electrical transport properties of VO 2 thin films fabricated by so–gel technique on alumina substrates has been demonstrated in the present paper. The point defects created by SHI irradiation modulate metal to insulator phase transition temperature, carrier concentration, carrier mobility, electrical conductivity, and Seebeck coefficient of VO 2 thin films. The structural properties of the films were characterized by XRD and Raman spectroscopy and crystallite size was found to decrease upon irradiation. The atomic force microscopy revealed that the surface roughness of specimens first decreased and then increased with increasing fluence. Both resistance as well as Seebeck coefficient measurements demonstrated that all the samples exhibit metal–insulator phase transition and the transition temperatures decreases with increasing fluence. Hall effect measurements exhibited that carrier concentration increased continuously with increasing fluence which resulted in an increase of electrical conductivity by several orders of magnitude in the insulating phase. Seebeck coefficient in insulating phase remained almost constant in spite of an increase in the electrical conductivity by several orders of magnitude making SHI irradiation an alternative stratagem for augmentation of thermoelectric performance of the materials. The carrier mobility at room temperature decreased up to the beam fluence of 5E11 and then started increasing whereas Seebeck coefficient in metallic state first increased with increasing ion beam fluence up to 5E11 and thereafter decreased. Variation of these electrical transport parameters has been explained in detail. - Highlights: • Thermoelectric properties of VO 2 thin films enhance upon SHI irradiation. • Structural properties show that crystallite size decrease upon SHI irradiation. • Metal–insulator phase

  10. Effects of exercise and group counselling on body composition and VO(2max) in overweight women with polycystic ovary syndrome

    DEFF Research Database (Denmark)

    Roessler, Kirsten Kaya; Birkebaek, Camilla; Ravn, Pernille

    2013-01-01

    with group counselling sessions on anthropometry and cardio-respiratory fitness in women with PCOS. DESIGN: Seventeen sedentary, overweight women with PCOS were randomized in a cross-over design to 16 weeks of intervention: Eight weeks high intensity aerobic exercise was followed by eight weeks group...... counselling (n=8) or vice versa (n=9). Fourteen of the women completed the tests. MAIN OUTCOME MEASURES: Waist circumference, body mass index and maximal aerobic capacity (VO(2max) ) were measured at baseline, cross-over and post-intervention. RESULTS: Waist circumference (119.9 vs. 106.5 cm) and body mass...

  11. Desenvolvimento de equações para estimativa do VO2PICO pelo teste de 9 minutos

    Directory of Open Access Journals (Sweden)

    Ana Carolina Paludo

    2014-06-01

    Full Text Available OBJETIVO: Desenvolver e validar modelos matemáticos para predição do VO2pico em crianças e adolescentes, por meio da utilização do teste de campo de corrida/caminhada de 9 minutos. MÉTODOS: Foram avaliados 211 escolares, de sete a 12 anos de idade, de ambos os sexos, regularmente matriculados em duas escolas do Município de Londrina - PR, sendo 141 escolares separados para amostra de desenvolvimento e 70 para validação das equações desenvolvidas. As medidas avaliadas foram: massa corporal, estatura, espessuras de dobras cutâneas (tricipital e subescapular, além da maturação biológica. Os testes de corrida/caminha de 9 minutos foram realizados em pista de atletismo e a análise direta do VO2pico (mL/kg/min realizada em laboratório, com analisador de gás portátil, através um teste incremental em esteira rolante. O desenvolvimento das equações foi realizado através da análise de regressão linear pelo método stepwise e a validação foi realizada pelos testes matemáticos específicos levando em consideração uma significância de 5% para todas as análises. RESULTADOS: A equação geral para a amostra total foi VO2pico= 24,506+16,672 (maturação, 0=pré e 1=púbere e pós - 0,346 (Σ DC + 5,187 (sexo, 0=F e 1=M + 0,009 (distância com um r=0,742 e EPE=9,149 mL/kg/min e sua validação apresentou r=0,570, CCI= 0,68, limites de concordância de -1,4 mL/kg/min, EPE=8,39 mL/kg/min e CV= 21,94%. CONCLUSÃO: Conclui-se que a equação generalizada desenvolvida fornece uma estimativa válida do VO2pico em crianças e adolescentes de sete a 12 anos de idade.

  12. Silver Vanadium Phosphorous Oxide, Ag(2)VO(2)PO(4): Chimie Douce Preparation and Resulting Lithium Cell Electrochemistry.

    Science.gov (United States)

    Kim, Young Jin; Marschilok, Amy C; Takeuchi, Kenneth J; Takeuchi, Esther S

    2011-08-15

    Recently, we have shown silver vanadium phosphorous oxide (Ag(2)VO(2)PO(4), SVPO) to be a promising cathode material for lithium based batteries. Whereas the first reported preparation of SVPO employed an elevated pressure, hydrothermal approach, we report herein a novel ambient pressure synthesis method to prepare SVPO, where our chimie douce preparation is readily scalable and provides material with a smaller, more consistent particle size and higher surface area relative to SVPO prepared via the hydrothermal method. Lithium electrochemical cells utilizing SVPO cathodes made by our new process show improved power capability under constant current and pulse conditions over cells containing cathode from SVPO prepared via the hydrothermal method.

  13. Nonlinear interaction of infrared waves on a VO2 surface at a semiconductor-metal phase transition

    Science.gov (United States)

    Berger, N. K.; Zhukov, E. A.; Novokhatskii, V. V.

    1984-04-01

    Nonlinear interactions (including wavefront reversal) of light from CW or pulsed 10.6-micron CO2 lasers at the semiconductor-metal phase transition in a VO2 film are investigated experimentally. The results are presented in graphs and characterized in detail. The intensity reflection coefficients of the three-wave interactions are found to be 0.5 percent for a CW reference wave of intensity 900 mW/sq cm and 42 percent for a pulsed reference wave of threshold density 600-800 microjoule/sq cm.

  14. Duration of effects of acute environmental changes on food anticipatory behaviour, feed intake, oxygen consumption, and cortisol release in Atlantic salmon parr.

    Science.gov (United States)

    Folkedal, Ole; Torgersen, Thomas; Olsen, Rolf Erik; Fernö, Anders; Nilsson, Jonatan; Oppedal, Frode; Stien, Lars H; Kristiansen, Tore S

    2012-01-18

    We compared behavioural and physiological responses and recovery time after different acute environmental challenges in groups of salmon parr. The fish were prior to the study conditioned to a flashing light signalling arrival of food 30 s later to study if the strength of Pavlovian conditioned food anticipatory behaviour can be used to assess how salmon parr cope with various challenges. The effect on anticipatory behaviour was compared to the effect on feed intake and physiological responses of oxygen hyper-consumption and cortisol excretion. The challenges were temperature fluctuation (6.5C° over 4 h), hyperoxia (up to 380% O(2) saturation over 4 h), and intense chasing for 10 min. Cortisol excretion was only elevated after hyperoxia and chasing, and returned to baseline levels after around 3 h or less. Oxygen hyper-consumption persisted for even shorter periods. Feed intake was reduced the first feeding after all challenges and recovered within 3 h after temperature and hyperoxia, but was reduced for days after chasing. Food anticipatory behaviour was reduced for a longer period than feed intake after hyperoxia and was low at least 6 h after chasing. Our findings suggest that a recovery of challenged Atlantic salmon parr to baseline levels of cortisol excretion and oxygen consumption does not mean full recovery of all psychological and physiological effects of environmental challenges, and emphasise the need for measuring several factors including behavioural parameters when assessing fish welfare. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Heart rate during basketball game play and volleyball drills accurately predicts oxygen uptake and energy expenditure.

    Science.gov (United States)

    Scribbans, T D; Berg, K; Narazaki, K; Janssen, I; Gurd, B J

    2015-09-01

    There is currently little information regarding the ability of metabolic prediction equations to accurately predict oxygen uptake and exercise intensity from heart rate (HR) during intermittent sport. The purpose of the present study was to develop and, cross-validate equations appropriate for accurately predicting oxygen cost (VO2) and energy expenditure from HR during intermittent sport participation. Eleven healthy adult males (19.9±1.1yrs) were recruited to establish the relationship between %VO2peak and %HRmax during low-intensity steady state endurance (END), moderate-intensity interval (MOD) and high intensity-interval exercise (HI), as performed on a cycle ergometer. Three equations (END, MOD, and HI) for predicting %VO2peak based on %HRmax were developed. HR and VO2 were directly measured during basketball games (6 male, 20.8±1.0 yrs; 6 female, 20.0±1.3yrs) and volleyball drills (12 female; 20.8±1.0yrs). Comparisons were made between measured and predicted VO2 and energy expenditure using the 3 equations developed and 2 previously published equations. The END and MOD equations accurately predicted VO2 and energy expenditure, while the HI equation underestimated, and the previously published equations systematically overestimated VO2 and energy expenditure. Intermittent sport VO2 and energy expenditure can be accurately predicted from heart rate data using either the END (%VO2peak=%HRmax x 1.008-17.17) or MOD (%VO2peak=%HRmax x 1.2-32) equations. These 2 simple equations provide an accessible and cost-effective method for accurate estimation of exercise intensity and energy expenditure during intermittent sport.

  16. Children-Adult Comparisons of VO2 and HR Kinetics during Submaximum Exercise.

    Science.gov (United States)

    Sady, Stanley P.; And Others

    1983-01-01

    Oxygen uptake and heart rate kinetics for submaximum exercise (bicycle riding) were compared in prepubescent boys and adult men. Resulting data suggest that children and adults do not differ significantly in cardiorespiratory adjustments during low-intensity exercise. (Authors/PP)

  17. Resolving the chicken-and-egg problem in VO2: a new paradigm for the Mott transition

    Science.gov (United States)

    Najera, Oscar; Civelli, Marcello; Dobrosavljevi, Vladimir; Rozenberg, Marcelo

    We consider a minimal model to investigate the metal-insulator transition in VO2. We adopt a Hubbard model with two orbital per unit cell, which captures the competition between Mott and singlet-dimer localization. We solve the model within Dynamical Mean Field Theory, characterizing in detail the metal-insulator transition and finding new features in the electronic states. We compare our results with available experimental data obtaining good agreement in the relevant model parameter range. Crucially, we can account for puzzling optical conductivity data obtained within the hysteresis region, which we associate to a novel metallic state characterized by a split heavy quasiparticle band. Our results show that the thermal-driven insulator-to-metal transition in VO2 is entirely compatible with a Mott electronic mechanism, solving a long standing ''chicken-and-egg'' debate and calling for further research of ``Mottronics'' applications of this system. This work was partially supported by public Grants from the French National Research Agency (ANR), project LACUNES No ANR-13-BS04-0006-01, the NSF DMR-1005751 and DMR-1410132.

  18. Formation of different micro-morphologies from VO2 and ZnO crystallization using macro-porous silicon substrates

    Science.gov (United States)

    Salazar-Kuri, U.; Antúnez, E. E.; Estevez, J. O.; Olive-Méndez, Sion F.; Silva-González, N. R.; Agarwal, V.

    2017-05-01

    Square-shaped macropores produced by electrochemical anodization of n- and p-type Si wafers have been used as centers of nucleation to crystallize VO2 and ZnO. Substrate roughness dependent formation of different morphologies is revealed in the form of squared particles, spheres, bars and ribbons in the case of VO2 and hexagonal piles and spheres in the case of ZnO, have been observed.The presence of nano-/micro-metric crystals was studied through field emission scanning electron microscopy and energy dispersive X-ray spectroscopy mapping. Crystal structure of metal oxides was confirmed by micro-Raman spectroscopy. The growth of the different morphologies has been explained in terms of the surface free energy of a bare Si/SiO2 substrate and its modification originated from the roughness of the surface and of the walls of the porous substrates. This energy plays a crucial role on the minimization of the required energy to induce heterogeneous nucleation and crystal growth. Present work strengthens and provides an experimental evidence of roughness dependent metal oxide crystal growth with well-defined habits from pore corners and rough sides of the pore walls, similar to already reported protein crystals.

  19. Opposing effects of nitric oxide and prostaglandin inhibition on muscle mitochondrial VO2 during exercise

    DEFF Research Database (Denmark)

    Boushel, Robert C; Fuentes, Teresa; Hellsten, Ylva

    2012-01-01

    Nitric oxide (NO) and prostaglandins (PG) together play a role in regulation blood flow during exercise. NO also regulates mitochondrial oxygen consumption through competitive binding to cytochrome c oxidase. Indomethacin both uncouples and inhibits the electron transport chain in a concentration......-dependent manner, and thus inhibition of NO and PG may regulate both muscle oxygen delivery and utilization. The purpose of this study was to examine the independent and combined effects of NO and PG blockade (L-NMMA and indomethacin respectively) on mitochondrial respiration in human muscle following knee...... extension (KE) exercise. Mitochondrial respiration was measured ex-vivo by high resolution respirometry in saponin-permeabilized fibers following 6 min KE in control (CON, n=8), arterial infusion of LNMMA (n=4) and Indo (n=4) followed by combined inhibition of NO and PG (L-NMMA + Indo, n=8). ADP...

  20. Changes in Peak Oxygen Uptake and Plasma Volume in Fit and Unfit Subjects Following Exposure to a Simulation of Microgravity

    National Research Council Canada - National Science Library

    Convertino, Victor

    1997-01-01

    To test the hypothesis that the magnitude of reduction in plasma volume and work capacity following exposure to simulated microgravity is dependent on the initial level of aerobic fitness, peak oxygen uptake (VO2peak...

  1. The effect of neuromuscular blockade on oxygen consumption in sedated and mechanically ventilated pediatric patients after cardiac surgery.

    NARCIS (Netherlands)

    Lemson, J.; Driessen, J.J.; Hoeven, J.G. van der

    2008-01-01

    OBJECTIVE: To measure the effect of intense neuromuscular blockade (NMB) on oxygen consumption (VO(2)) in deeply sedated and mechanically ventilated children on the first day after complex congenital cardiac surgery. DESIGN: Prospective clinical interventional study. SETTING: Pediatric intensive

  2. Simultaneous sampling of tissue oxygenation and oxygen consumption in skeletal muscle.

    Science.gov (United States)

    Nugent, William H; Song, Bjorn K; Pittman, Roland N; Golub, Aleksander S

    2016-05-01

    Under physiologic conditions, microvascular oxygen delivery appears to be well matched to oxygen consumption in respiring tissues. We present a technique to measure interstitial oxygen tension (PISFO2) and oxygen consumption (VO2) under steady-state conditions, as well as during the transitions from rest to activity and back. Phosphorescence Quenching Microscopy (PQM) was employed with pneumatic compression cycling to achieve 1 to 10 Hz sampling rates of interstitial PO2 and simultaneous recurrent sampling of VO2 (3/min) in the exteriorized rat spinotrapezius muscle. The compression pressure was optimized to 120-130 mmHg without adverse effect on the tissue preparation. A cycle of 5s compression followed by 15s recovery yielded a resting VO2 of 0.98 ± 0.03 ml O2/100 cm(3)min while preserving microvascular oxygen delivery. The measurement system was then used to assess VO2 dependence on PISFO2 at rest and further tested under conditions of isometric muscle contraction to demonstrate a robust ability to monitor the on-kinetics of tissue respiration and the compensatory changes in PISFO2 during contraction and recovery. The temporal and spatial resolution of this approach is well suited to studies seeking to characterize microvascular oxygen supply and demand in thin tissues. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Non-linear relationship between oxygen uptake and power output in the Astrand nomogram-old data revisited.

    Science.gov (United States)

    Zoladz, J A; Szkutnik, Z; Majerczak, J; Duda, K; Pedersen, P K

    2007-06-01

    For the last decade there have been considerable discussion concerning the linearity / non-linearity of the oxygen uptake (V(O2)) - power output (W) relationship with strong experimental evidence of non-linearity provided mainly by breath-by-breath measurements. In this study, we attempted to answer the question whether the V(O2) - W relationship in the Astrand nomogram, as presented in the Textbook of Work Physiology, P.-O. Astrand et al. (2003), page 281, based on the Douglas bag method, is indeed linear, as stated by the authors before, or if a change point in V(O2), described by Zoladz et al. (1998) Eur J Appl Physiol 78: 369-377, can possibly be detected in those data. The V(O2) - W data were taken from the Astrand nomogram referenced above and from the Table 9.5 on page 282 in the same reference and tested for the presence of the change point in V(O2), using our two-phase model (see the reference above). In the first phase, a linear V(O2) - W relationship was assumed, whereas in the second one (above the so-called change point) an additional increase in V(O2) above the values expected from the linear model was allowed. It was found that in the data taken from the Astrand nomogram (data for men), as well as in the data taken from the Table 9.5, statistically significant change points in V(O2) were present at the power output of 150 W. The documentation of the presence of a change point in the V(O2) - W relationship in the Astrand data provides further evidence for the existence of a non-linearity in the V(O2) - W relationship in incremental exercise tests of humans, also in V(O2) data based upon the Douglas bag method.

  4. PELATIHAN LARI SIRKUIT 2 X 10 MENIT DAN PELATIHAN LARI KONTINYU 2 X 10 MENIT DAPAT MENINGKATKAN VO2 MAX TAEKWONDOIN PUTRA KABUPATEN MANGGARAI - NTT

    Directory of Open Access Journals (Sweden)

    Regina Sesilia Noy

    2014-08-01

    Full Text Available VO2 max is very important in everyday life, so as to facilitate any physicalactivity, specially for athletes in order to achieve maximum performance. In aneffort to increase VO2 max training should be carried out regularly, measured andplanned. This study aims to determine the increase in VO2 max through circuittraining run and run continuously. The sample is taekwondoin son Manggarai-NTTwith an average age of 15 years. This study is an experimental study with the studydesign used was Randomized Pre and Post Test Group desigen. With a totalsample of 7 people in each group. Samples were randomly selected. Treatmentgroup 1 (KP1 given training run circuit 2 x 10 minute and Treatment Group 2(KP2 are given continuous training run 2 x 10 minute. Training carried out for 6weeks with a frequency of four times a week starting at 17:00 to 18:00 pm locatedat Frans Sales Lega Airport Manggarai-NTT. The analysis showed an increase inVO2 max was significantly (p <0.05 against both groups fled. In both groups thecircuit run by Pulse Oxymeter and Norma Cooper an increase in VO2 max with p<0.05, as well as a continuous run either by Pulse Oxymeter and Norma Cooperwith an increase in VO2 max value of p <0.05. The results of this analysis meansthat either the training or circuit training run run continuously to improve VO2max. Based on a comparison of test data by an independent test after training inboth groups either by Pulse Oxymeter and Norma Cooper in get p values > 0.05, orthere is no significant difference. Based on these results it can be concluded thatthe run circuit training and continuous training run together can increase VO2 maxand there was no significant difference. The results of this study are expected toincrease the knowledge of coaches, teachers and taekwondoin to perform trainingon a regular basis and are also expected to do similar research that examines VO2max with different training.

  5. Metal-semiconductor transition materials. FeS and VO2 thin films by RF reactive sputtering

    International Nuclear Information System (INIS)

    Fu, Ganhua

    2007-06-01

    In the present work, two MST systems, FeS and VO 2 thin films were investigated. Iron sulfide thin films over a range of composition were prepared by reactive sputtering. The influence of the substrate, sputter power, substrate temperature and stoichiometry on the structure and MST of iron sulfide films was investigated. Iron sulfide films deposited at different temperatures show temperature dependent structure and MST. FeS films on float glass show (110) and (112) orientations when the substrate temperature is 200 and 500 C, respectively. The transition temperature and width of the hysteresis loop determined from the temperature dependent conductivity curves of iron sulfide films decrease with the substrate temperature. Fe and S excess in FeS films both result in the decrease of the transition temperature and width of the hysteresis loop. The vacuum-annealing affects the MST of FeS films significantly. When FeS films were annealed below the deposition temperature, the transition temperature decreases; otherwise increases. The residual stress plays an important role during the annealing process. The higher the residual stress inside the FeS films is, the higher the transition temperature of FeS films. With the increase of the annealing temperature, the residual stress in FeS films is first released and then enhances, which gives rise first to the decrease and then increase of the transition temperature of FeS films. At high substrate temperatures, the residual stress is higher. In addition, the MST of FeS films was influenced by the ambient aging. With the increase of the aging time, the transition temperature first increases and then decreases. FeS films with different thicknesses were prepared. The correlation between the film thickness (grain size) and the MST switching characteristics of FeS films was established. With the decrease of the grain size, the density of grain boundaries increases, causing the increase of the conductivity of the semiconducting phase

  6. Fabrication and electrical resistivity of Mo-doped VO2 thin films coated on graphite conductive plates by a sol-gel method

    Energy Technology Data Exchange (ETDEWEB)

    Choi, W.; Jung, H.M.; Um, S. [Hanyang Univ., Seoul (Korea, Republic of). School of Mechanical Engineering

    2008-07-01

    Vanadium oxides (VO2) can be used in optical devices, thermochromic smart windows and sensors. This paper reported on a study in which vanadium pentoxide (V2O5) powder was prepared and mixed with Molybdenum Oxides (MoO3) to form Mo-doped and -undoped VO2 thin films by a sol-gel method on graphite conductive substrates. The micro-structure and chemical compositions of the Mo-doped and -undoped VO2 thin films was investigated using X-Ray diffraction and scanning electron microscopy. Changes in electrical resistivity were measured as a function of the stoichiometric compositions between vanadium and molybdenum. In this study. Mo-doped and -undoped VO2 thin films showed the typical metal to insulator transition (MIT), where temperature range could be adjusted by modifying the dopant atomic ratio. The through-plane substrate structure of the Mo-doped layer influences the electrical resistivity of the graphite substrate. As the amount of the molybdenum increases, the electrical resistivity of the graphite conductive substrate decreases in the lower temperature range below the freezing point of water. The experimental results showed that if carefully controlled, thermal dissipation of VO2 thin films can be used as a self-heating source to melt frozen water with the electrical current flowing through the graphite substrate. 3 refs., 3 figs.

  7. Two-Dimensional SiO2/VO2 Photonic Crystals with Statically Visible and Dynamically Infrared Modulated for Smart Window Deployment.

    Science.gov (United States)

    Ke, Yujie; Balin, Igal; Wang, Ning; Lu, Qi; Tok, Alfred Iing Yoong; White, Timothy J; Magdassi, Shlomo; Abdulhalim, Ibrahim; Long, Yi

    2016-12-07

    Two-dimensional (2D) photonic structures, widely used for generating photonic band gaps (PBG) in a variety of materials, are for the first time integrated with the temperature-dependent phase change of vanadium dioxide (VO 2 ). VO 2 possesses thermochromic properties, whose potential remains unrealized due to an undesirable yellow-brown color. Here, a SiO 2 /VO 2 core/shell 2D photonic crystal is demonstrated to exhibit static visible light tunability and dynamic near-infrared (NIR) modulation. Three-dimensional (3D) finite difference time domain (FDTD) simulations predict that the transmittance can be tuned across the visible spectrum, while maintaining good solar regulation efficiency (ΔT sol = 11.0%) and high solar transmittance (T lum = 49.6%). Experiments show that the color changes of VO 2 films are accompanied by NIR modulation. This work presents a novel way to manipulate VO 2 photonic structures to modulate light transmission as a function of wavelength at different temperatures.

  8. Oxygen uptake efficiency slope and peak oxygen consumption predict prognosis in children with tetralogy of Fallot.

    Science.gov (United States)

    Tsai, Yun-Jeng; Li, Min-Hui; Tsai, Wan-Jung; Tuan, Sheng-Hui; Liao, Tin-Yun; Lin, Ko-Long

    2016-07-01

    Oxygen uptake efficiency slope (OUES) and peak oxygen consumption (VO2peak) are exercise parameters that can predict cardiac morbidity in patients with numerous heart diseases. But the predictive value in patients with tetralogy of Fallot is still undetermined, especially in children. We evaluated the prognostic value of OUES and VO2peak in children with total repair of tetralogy of Fallot. Retrospective cohort study. Forty tetralogy of Fallot patients younger than 12 years old were recruited. They underwent a cardiopulmonary exercise test during the follow-up period after total repair surgery. The results of the cardiopulmonary exercise test were used to predict the cardiac related hospitalization in the following two years after the test. OUES normalized by body surface area (OUES/BSA) and the percentage of predicted VO2peak appeared to be predictive for two-year cardiac related hospitalization. Receiver operating characteristic curve analysis demonstrated that the best threshold value for OUES/BSA was 1.029 (area under the curve = 0.70, p = 0.03), and for VO2peak was 74% of age prediction (area under the curve = 0.72, p = 0.02). The aforementioned findings were confirmed by Kaplan-Meier plots and log-rank test. OUES/BSA and VO2peak are useful predictors of cardiac-related hospitalization in children with total repair of tetralogy of Fallot. © The European Society of Cardiology 2015.

  9. High content of MYHC II in vastus lateralis is accompanied by higher VO2/power output ratio during moderate intensity cycling performed both at low and at high pedalling rates.

    Science.gov (United States)

    Majerczak, J; Szkutnik, Z; Karasinski, J; Duda, K; Kolodziejski, L; Zoladz, J A

    2006-06-01

    The aim of this study was to examine the relationship between the content of various types of myosin heavy chain isoforms (MyHC) in the vastus lateralis muscle and pulmonary oxygen uptake during moderate power output incremental exercise, performed at low and at high pedalling rates. Twenty one male subjects (mean +/- SD) aged 24.1 +/- 2.8 years; body mass 72.9 +/- 7.2 kg; height 179.1 +/- 4.8 cm; BMI 22.69 +/- 1.89 kg.m(-2); VO2max 50.6 +/- 5.3 ml.kg.min(-1), participated in this study. On separate days, they performed two incremental exercise tests at 60 rev.min(-1) and at 120 rev.min(-1), until exhaustion. Gas exchange variables were measured continuously breath by breath. Blood samples were taken for measurements of plasma lactate concentration prior to the exercise test and at the end of each step of the incremental exercise. Muscle biopsies were taken from the vastus lateralis muscle, using Bergström needle, and they were analysed for the content of MyHC I and MyHC II using SDS--PAGE and two groups (n=7, each) were selected: group H with the highest content of MyHC II (60.7 % +/- 10.5 %) and group L with the lowest content of MyHC II (27.6 % +/- 6.1 %). We have found that during incremental exercise at the power output between 30-120 W, performed at 60 rev.min(-1), oxygen uptake in the group H was significantly greater than in the group L (ANCOVA, p=0.003, upward shift of the intercept in VO2/power output relationship). During cycling at the same power output but at 120 rev.min(-1), the oxygen uptake was also higher in the group H, when compared to the group L (i.e. upward shift of the intercept in VO2/power output relationship, ANCOVA, p=0.002). Moreover, the increase in pedalling rate from 60 to 120 rev.min(-1) was accompanied by a significantly higher increase of oxygen cost of cycling and by a significantly higher plasma lactate concentration in subjects from group H. We concluded that the muscle mechanical efficiency, expressed by the VO2/PO ratio

  10. Pemberian minuman kombinasi maltodekstrin dan vitamin C terhadap mood negatif dan VO2 maks atlet sepak bola

    Directory of Open Access Journals (Sweden)

    Yuni Afriani

    2017-04-01

    Full Text Available Background: Stress during the match can influence the change of mood and performance of athletes. Physical exercise can improve the ability of physiologically and psychologically, but lead to fatigue, dehydration and hypoglycemia. Maltodextrin has a lower osmolarity to improve emotional and performance. Vitamin C as a cofactor of neurotransmitters can support the performance of athletes. Objective: This study aimed to determine the effectiveness of a combination drinks of maltodextrin and vitamin C on mood and the correlation with VO2 max of football athletes. Method: This research is a quasi experimental with same subject design. The subjects were 14 University state of Yogyakarta football athlete. Subjects received a drink of 15% maltodextrin and 250 mg of vitamin C in 300 ml given 30 minutes before and 5 minutes after the performance test using yo-yo intermittent test continued by physical exercise. Measurement of mood would be done in 3 times; before cardiorespiratory test, 5 minutes after physical exercise, and 15 minutes after drink. Results: There are significant changes after consuming a combination of maltodextrin and vitamin C on the confusion (p0.05. There are significant changes after consuming plain water on fatigue and tension (p0.05. There are no significant differences in every components of mood between two treatments. There is a correlation between anger and confusion with cardiorespiratory after consuming a combination of maltodextrin and vitamin C. Conclusion: Maltodextrin and vitamin C has the potential effect to improve the mood condition and have a correlation with VO2 Max improvement in football athletes.

  11. Høyintensiv aerob intervalltrening utført som ekstrembolk fører ikke til endringer i VO2max hos elitesyklister og ??riatleter

    OpenAIRE

    Pedersen, Frank-Gøran

    2014-01-01

    HENSIKT: Studien hadde til hensikt å undersøke virkningen av høyintensiv aerob intervalltrening (HAIT) på maksimalt oksygenopptak (VO2max) og tid på Time trial (TT) hos elitesyklister og triatleter. METODE: 11 forsøkspersoner, n=7 HAIT (31±9) og n=4 kontroll (27±11), VO2max HAIT 62.6±6.4, VO2max 65.6±5.7 gjennomførte denne studien. HAIT gjennomførte 14 intervalløkter (4x4 løpeintervaller på tredemølle, 3-5%stigning, 90-95% av Hfmax, 3 minutter aktiv hvile på ca. 70% av Hfmax) over ti dager,et...

  12. Muscle mitochondrial capacity exceeds maximal oxygen delivery in humans

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Gnaiger, Erich; Calbet, Jose A L

    2011-01-01

    Across a wide range of species and body mass a close matching exists between maximal conductive oxygen delivery and mitochondrial respiratory rate. In this study we investigated in humans how closely in-vivo maximal oxygen consumption (VO(2) max) is matched to state 3 muscle mitochondrial respira...

  13. New intelligent multifunctional SiO2/VO2 composite films with enhanced infrared light regulation performance, solar modulation capability, and superhydrophobicity.

    Science.gov (United States)

    Wang, Chao; Zhao, Li; Liang, Zihui; Dong, Binghai; Wan, Li; Wang, Shimin

    2017-01-01

    Highly transparent, energy-saving, and superhydrophobic nanostructured SiO 2 /VO 2 composite films have been fabricated using a sol-gel method. These composite films are composed of an underlying infrared (IR)-regulating VO 2 layer and a top protective layer that consists of SiO 2 nanoparticles. Experimental results showed that the composite structure could enhance the IR light regulation performance, solar modulation capability, and hydrophobicity of the pristine VO 2 layer. The transmittance of the composite films in visible region ( T lum ) was higher than 60%, which was sufficient to meet the requirements of glass lighting. Compared with pristine VO 2 films and tungsten-doped VO 2 film, the near IR control capability of the composite films was enhanced by 13.9% and 22.1%, respectively, whereas their solar modulation capability was enhanced by 10.9% and 22.9%, respectively. The water contact angles of the SiO 2 /VO 2 composite films were over 150°, indicating superhydrophobicity. The transparent superhydrophobic surface exhibited a high stability toward illumination as all the films retained their initial superhydrophobicity even after exposure to 365 nm light with an intensity of 160 mW . cm -2 for 10 h. In addition, the films possessed anti-oxidation and anti-acid properties. These characteristics are highly advantageous for intelligent windows or solar cell applications, given that they can provide surfaces with anti-fogging, rainproofing, and self-cleaning effects. Our technique offers a simple and low-cost solution to the development of stable and visible light transparent superhydrophobic surfaces for industrial applications.

  14. The Impact of Firefighter Personal Protective Equipment and Treadmill Protocol on Maximal Oxygen Uptake

    Science.gov (United States)

    Lee, Joo-Young; Bakri, Ilham; Kim, Jung-Hyun; Son, Su-Young; Tochihara, Yutaka

    2015-01-01

    This study investigated the effects of firefighter personal protective equipment (PPE) on the determination of maximal oxygen uptake (VO2max) while using two different treadmill protocols: a progressive incline protocol (PIP) and a progressive speed protocol (PSP), with three clothing conditions (Light-light clothing; Boots-PPE with rubber boots; Shoes-PPE with running shoes). Bruce protocol with Light was performed for a reference test. Results showed there was no difference in VO2max between Bruce Light, PIP Light, and PSP Light. However, VO2max was reduced in Boots and Shoes with shortened maximal performance time (7 and 6 min reduced for PIP Boots and Shoes, respectively; 11 and 9 min reduced for PSP Boots and Shoes, respectively), whereas the increasing rate of VO2 in Boots and Shoes during submaximal exercise was greater compared with Light. Wearing firefighter boots compared with wearing running shoes also significantly affected submaximal VO2 but not VO2max. These results suggest that firefighters’ maximal performance determined from a typical VO2max test without wearing PPE may overestimate the actual performance capability of firefighters wearing PPE. PMID:23668854

  15. Rates of oxygen uptake increase independently of changes in heart rate in late stages of development and at hatching in the green iguana, Iguana iguana.

    Science.gov (United States)

    Sartori, Marina R; Abe, Augusto S; Crossley, Dane A; Taylor, Edwin W

    2017-03-01

    Oxygen consumption (VO 2 ), heart rate (f H ), heart mass (M h ) and body mass (M b ) were measured during embryonic incubation and in hatchlings of green iguana (Iguana iguana). Mean f H and VO 2 were unvarying in early stage embryos. VO 2 increased exponentially during the later stages of embryonic development, doubling by the end of incubation, while f H was constant, resulting in a 2.7-fold increase in oxygen pulse. Compared to late stage embryos, the mean inactive level of VO 2 in hatchlings was 1.7 fold higher, while f H was reduced by half resulting in a further 3.6 fold increase in oxygen pulse. There was an overall negative correlation between mean f H and VO 2 when data from hatchlings was included. Thus, predicting metabolic rate as VO 2 from measurements of f H is not possible in embryonic reptiles. Convective transport of oxygen to supply metabolism during embryonic incubation was more reliably indicated as an index of cardiac output (CO i ) derived from the product of f H and M h . However, a thorough analysis of factors determining rates of oxygen supply during development and eclosion in reptiles will require cannulation of blood vessels that proved impossible in the present study, to determine oxygen carrying capacity by the blood and arteriovenous oxygen content difference (A-V diff), plus patterns of blood flow. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. A prospective population study of resting heart rate and peak oxygen uptake (the HUNT Study, Norway.

    Directory of Open Access Journals (Sweden)

    Javaid Nauman

    Full Text Available OBJECTIVES: We assessed the prospective association of resting heart rate (RHR at baseline with peak oxygen uptake (VO(2peak 23 years later, and evaluated whether physical activity (PA could modify this association. BACKGROUND: Both RHR and VO(2peak are strong and independent predictors of cardiovascular morbidity and mortality. However, the association of RHR with VO(2peak and modifying effect of PA have not been prospectively assessed in population studies. METHODS: In 807 men and 810 women free from cardiovascular disease both at baseline (1984-86 and follow-up 23 years later, RHR was recorded at both occasions, and VO(2peak was measured by ergospirometry at follow-up. We used Generalized Linear Models to assess the association of baseline RHR with VO(2peak, and to study combined effects of RHR and self-reported PA on later VO(2peak. RESULTS: There was an inverse association of RHR at baseline with VO(2peak (p<0.01. Men and women with baseline RHR greater than 80 bpm had 4.6 mL.kg(-1.min(-1 (95% confidence interval [CI], 2.8 to 6.3 and 1.4 mL.kg(-1.min(-1 (95% CI, -0.4 to 3.1 lower VO(2peak at follow-up compared with men and women with RHR below 60 bpm at baseline. We found a linear association of change in RHR with VO(2peak (p=0.03, suggesting that a decrease in RHR over time is likely to be beneficial for cardiovascular fitness. Participants with low RHR and high PA at baseline had higher VO(2peak than inactive people with relatively high RHR. However, among participants with relatively high RHR and high PA at baseline, VO(2peak was similar to inactive people with relatively low RHR. CONCLUSION: RHR is an important predictor of VO(2peak, and serial assessments of RHR may provide useful and inexpensive information on cardiovascular fitness. The results suggest that high levels of PA may compensate for the lower VO(2peak associated with a high RHR.

  17. Endurance training decreases the non-linearity in the oxygen uptake-power output relationship in humans.

    Science.gov (United States)

    Majerczak, Joanna; Korostynski, Michal; Nieckarz, Zenon; Szkutnik, Zbigniew; Duda, Krzysztof; Zoladz, Jerzy A

    2012-03-01

    In this study, we hypothesized that 5 weeks of cycling endurance training can decrease the magnitude of the non-proportional increase in oxygen uptake (V(O(2))) to power output relationship (V(O(2)) 'excess') at exercise intensities exceeding the lactate threshold (LT). Ten untrained, physically active men performed a bout of incremental cycling exercise until exhaustion before and after training. The mitochondrial DNA copy number, myosin heavy chain composition and content of uncoupling protein 3 and sarcoplasmic reticulum Ca(2+)-ATPases (SERCAs) were analysed in muscle biopsies taken from vastus lateralis before and after training. The training resulted in an enhancement of the power-generating capabilities at maximal oxygen uptake (V(O(2)max)) by ∼7% (P = 0.002) despite there being no changes in V(O(2)max) (P = 0.49). This effect was due to a considerable reduction in the magnitude of the V(O(2)) 'excess' (P 0.05) were found after training. We conclude that the training-induced increase in power-generating capabilities at V(O(2)max) was due to attenuation of the V(O(2)) 'excess' above the LT. This adaptive response seems to be related to the improvement of muscle metabolic stability, as judged by a lowering of plasma ammonia concentration. The enhancement of muscle metabolic stability after training could be caused by a decrease in ATP usage at a given power output owing to downregulation of SERCA2 pumps.

  18. Effect of training in the fasted state on metabolic responses during exercise with carbohydrate intake

    DEFF Research Database (Denmark)

    De Bock, K; Derave, W; Eijnde, B O

    2008-01-01

    program (6 wk, 3 day/wk, 1-2 h, 75% of peak Vo(2)) in moderately active males. They trained in the fasted (F; n = 10) or carbohydrate-fed state (CHO; n = 10) while receiving a standardized diet [65 percent of total energy intake (En) from carbohydrates, 20%En fat, 15%En protein]. Before and after...... the training period, substrate use during a 2-h exercise bout was determined. During these experimental sessions, all subjects were in a fed condition and received extra carbohydrates (1 g.kg body wt(-1) .h(-1)). Peak Vo(2) (+7%), succinate dehydrogenase activity, GLUT4, and hexokinase II content were...... adaptations in peak Vo(2) whether carried out in the fasted or carbohydrate-fed state. Although there was a decrease in exercise-induced glycogen breakdown and an increase in proteins involved in fat handling after fasting training, fat oxidation during exercise with carbohydrate intake was not changed....

  19. Decoupling the Lattice Distortion and Charge Doping Effects on the Phase Transition Behavior of VO2 by Titanium (Ti4+) Doping

    Science.gov (United States)

    Wu, Yanfei; Fan, Lele; Liu, Qinghua; Chen, Shi; Huang, Weifeng; Chen, Feihu; Liao, Guangming; Zou, Chongwen; Wu, Ziyu

    2015-01-01

    The mechanism for regulating the critical temperature (TC) of metal-insulator transition (MIT) in ions-doped VO2 systems is still a matter of debate, in particular, the unclear roles of lattice distortion and charge doping effects. To rule out the charge doping effect on the regulation of TC, we investigated Ti4+-doped VO2 (TixV1-xO2) system. It was observed that the TC of TixV1-xO2 samples first slightly decreased and then increased with increasing Ti concentration. X-ray absorption fine structure (XAFS) spectroscopy was used to explore the electronic states and local lattice structures around both Ti and V atoms in TixV1-xO2 samples. Our results revealed the local structure evolution from the initial anatase to the rutile-like structure around the Ti dopants. Furthermore, the host monoclinic VO2 lattice, specifically, the VO6 octahedra would be subtly distorted by Ti doping. The distortion of VO6 octahedra and the variation of TC showed almost the similar trend, confirming the direct effect of local structural perturbations on the phase transition behavior. By comparing other ion-doping systems, we point out that the charge doping is more effective than the lattice distortion in modulating the MIT behavior of VO2 materials. PMID:25950809

  20. Intracellular [Ca2+] and Vo2 after manipulation of the free-energy of the Na+/Ca(2+)-exchanger in isolated rat ventricular myocytes

    NARCIS (Netherlands)

    Fiolet, J. W.; Baartscheer, A.; Schumacher, C. A.

    1995-01-01

    We have investigated whether the Na+/Ca(2+)-exchanger has a functional regulatory role in the control of oxidative metabolism in suspensions of isolated rat ventricular myocytes. Therefore we simultaneously measured intracellular [Ca2+] ([Ca2+]i) with Indo-1 and respiratory rate (Vo2) after abrupt

  1. Room-temperature subnanosecond waveguide lasers in Nd:YVO4 Q-switched by phase-change VO2: A comparison with 2D materials.

    Science.gov (United States)

    Nie, Weijie; Li, Rang; Cheng, Chen; Chen, Yanxue; Lu, Qingming; Romero, Carolina; Vázquez de Aldana, Javier R; Hao, Xiaotao; Chen, Feng

    2017-04-06

    We report on room-temperature subnanosecond waveguide laser operation at 1064 nm in a Nd:YVO 4 crystal waveguide through Q-switching of phase-change nanomaterial vanadium dioxide (VO 2 ). The unique feature of VO 2 nanomaterial from the insulating to metallic phases offers low-saturation-intensity nonlinear absorptions of light for subnanosecond pulse generation. The low-loss waveguide is fabricated by using the femtosecond laser writing with depressed cladding geometry. Under optical pump at 808 nm, efficient pulsed laser has been achieved in the Nd:YVO 4 waveguide, reaching minimum pulse duration of 690 ps and maximum output average power of 66.7 mW. To compare the Q-switched laser performances by VO 2 saturable absorber with those based on two-dimensional materials, the 1064-nm laser pulses have been realized in the same waveguide platform with either graphene or transition metal dichalcogenide (in this work, WS 2 ) coated mirror. The results on 2D material Q-switched waveguide lasers have shown that the shortest pulses are with 22-ns duration, whilst the maximum output average powers reach ~161.9 mW. This work shows the obvious difference on the lasing properties based on phase-change material and 2D materials, and suggests potential applications of VO 2 as low-cost saturable absorber for subnanosecond laser generation.

  2. Growth of VO2 Nano wires from Supercooled Liquid Nano droplets and E-beam Irradiation for Ultra-sensitive sensor

    International Nuclear Information System (INIS)

    Byun, Ji Won; Baik, Jeong Min; Lee, Sang Hyun; Lee, Byung Cheol

    2011-01-01

    Vanadium dioxide is an interesting material on account of its easily accessible and sharp Mott metal-insulator transition at ∼ 68 .deg. C in the bulk, which is of great interest in sensing and catalytic applications. In this Paper, we describe the synthesis and properties of VO 2 nano wires as novel catalytic and gas sensor materials based on electron beam irradiation. High yields of single crystalline VO 2 nano wires are synthesized by atmospheric-pressure, physical vapor deposition using V 2 O 5 layer. Pd-decorated VO 2 nano wire sensors show extraordinary sensitivity towards hydrogen, an almost 3 order-of-magnitude increase in the current through the nano wire. By the Eb irradiation, the conductance of the nano wires significantly increased up to 5 times, reducing the response time by half and the operating temperature. The metal nanoparticles-VO 2 nano wire system will be very promising for high-sensitivity and high-selectivity under low temperature less than 100. deg. C

  3. Raman spectroscopy of WO3 nano-wires and thermo-chromism study of VO2 belts produced by ultrasonic spray and laser pyrolysis techniques

    CSIR Research Space (South Africa)

    Mwakikunga, BW

    2008-01-01

    Full Text Available . This was carried out us- ing MathmatcaTM. Electrical resistances of the VO2 (R) nanobelts (NBs) were measured at different points on the sample using a digital multi-meter and heated base coupled with a tem- perature controller. The Varian Cary 500...

  4. Body composition, VO2máx. and the lifestyle of young students of the higher education

    Directory of Open Access Journals (Sweden)

    R.M. Antúnez

    2008-01-01

    Full Text Available OBJECTIVE: The purpose of this study was to characterize the subjects of the sample in what concerns their corporal composition, through the index of corporal mass and of the percentage of fat mass, their cardiorespiratory capacity, their eating and smoking habits, and indexes of practice of physical activity. It also aimed to verify if there were statistically relevant relationships between these variables. METHODS: The study was carried out in 2006 and 2007, in Beja, a city in the South of Portugal. The sample comprised 183 students attending the first year of all the courses of a higher education institution in the school year of 2006/07, with ages ranging from 18 to 40 years old. Through a questionnaire, the Astrand Test, and the technique of electric bioimpedance, we obtained the results that allowed us to reach the intended objectives. We used the program Bodygram to obtain the data related to the index of corporal mass and the percentage of fat mass, and the program SPSS, version 14.0, to accomplish the descriptive analysis of the data, a variance analysis and also a correlational analysis. RESULTS: We found evidence that 62.8% of the subjects of the sample presented values of percentage of fat mass above the recommended limits and that 55.7% obtained very low values of VO2max. We also found that 61.7% didn't consider themselves active subjects in what concerns the regular practice of physical activity, and that this variable was correlated with VO2máx. (p=0.01 CONCLUSIONS: We could conclude that most of the subjects of our sample presented low indexes of physical activity, deficient cardiorespiratory capacity and high values in what concerns the percentage of fat mass. The practice of physical activity showed to be positively correlated with the cardiorespiratory capacity. It is necessary to implement more effective campaigns to combat obesity and to sensitize for the regular practice of physical activity and for good eating habits.

  5. Effects of acute L-carnitine intake on metabolic and blood lactate levels of elite badminton players.

    Science.gov (United States)

    Eroğlu, Hüseyin; Senel, Omer; Güzel, Nevin A

    2008-04-01

    Purpose of this study is to research the effects of acute L-Carnitine intake on badminton players' metabolic and blood lactate values. A total of 16 Turkish national badminton players (8 male, 8 female) were voluntarily participated into study. MaxVO2, MET, energy consumption, HR (heart rate), VE (minute ventilation), R (respiratory exchange ratio), AT (anaerobic threshold), oxygen pulse and blood lactate (LA) of subjects were measured by Sensormedics VmaxST and Accutrend Lactate Analyzer. The participants were subjected to the test protocol twice before and after 2g of L-Carnitine intake. The data were evaluated by the use of SPSS 13.0 for Windows. No significant differences were found between 1st. (without L-Carnitine intake) and 2nd. (with L-Carnitine intake) measurements of female participants as regards to all measured parameters. There was a significant difference in EMHR (exercise maximum heart rate) of males between two measurements (p0.05). Respiratory exchange ratio of males was significantly different at anaerobic threshold (pbadminton players.

  6. Machine learning and statistical methods for the prediction of maximal oxygen uptake: recent advances

    Directory of Open Access Journals (Sweden)

    Abut F

    2015-08-01

    Full Text Available Fatih Abut, Mehmet Fatih AkayDepartment of Computer Engineering, Çukurova University, Adana, TurkeyAbstract: Maximal oxygen uptake (VO2max indicates how many milliliters of oxygen the body can consume in a state of intense exercise per minute. VO2max plays an important role in both sport and medical sciences for different purposes, such as indicating the endurance capacity of athletes or serving as a metric in estimating the disease risk of a person. In general, the direct measurement of VO2max provides the most accurate assessment of aerobic power. However, despite a high level of accuracy, practical limitations associated with the direct measurement of VO2max, such as the requirement of expensive and sophisticated laboratory equipment or trained staff, have led to the development of various regression models for predicting VO2max. Consequently, a lot of studies have been conducted in the last years to predict VO2max of various target audiences, ranging from soccer athletes, nonexpert swimmers, cross-country skiers to healthy-fit adults, teenagers, and children. Numerous prediction models have been developed using different sets of predictor variables and a variety of machine learning and statistical methods, including support vector machine, multilayer perceptron, general regression neural network, and multiple linear regression. The purpose of this study is to give a detailed overview about the data-driven modeling studies for the prediction of VO2max conducted in recent years and to compare the performance of various VO2max prediction models reported in related literature in terms of two well-known metrics, namely, multiple correlation coefficient (R and standard error of estimate. The survey results reveal that with respect to regression methods used to develop prediction models, support vector machine, in general, shows better performance than other methods, whereas multiple linear regression exhibits the worst performance

  7. Inclusão do equivalente energético do lactato na regressão VO2-intensidade em corrida horizontal e inclinada (10,5%

    Directory of Open Access Journals (Sweden)

    Victor Machado REIS

    Full Text Available Resumo O estudo teve por objetivo analisar o efeito da adição do equivalente energético do lactato sanguíneo com a medida de VO2 durante a corrida em esteira horizontal (0% e inclinada (10,5%, como forma de estimativa do custo energético da corrida. Treze corredores de meia e longa distância (idade 28,1 ± 4,2 anos; estatura 1,75 ± 0,07 m; massa corporal 65,2 ± 4,9 kg; VO2max 70,3 ± 4,9 ml·kg-1·min-1 cumpriram dois testes em esteira rolante (0% e 10,5% que incluíram vários estágios em intensidade constante. Foram calculadas para cada atleta as regressões VO2-velocidade, bem como regressões alternativas com a adição de um equivalente energético de 3 ml O2 Eq·kg-1·mM [La-] às medições de VO2. Não se verificou interação significativa entre a adição do equivalente do lactato e a inclinação da esteira. A ANOVA indicou um efeito significativo da adição do equivalente do lactato na inclinação da reta de regressão e na estimativa do custo energético. Os tamanhos do efeito obtidos indicam que este efeito é mais forte na corrida horizontal. Estes resultados sugerem que em testes laboratoriais com corredores treinados se deverá considerar a adição dos valores de VO2 com os equivalentes energéticos do lactato.

  8. Peak Exercise Oxygen Uptake Predicts Recurrent Admissions in Heart Failure With Preserved Ejection Fraction.

    Science.gov (United States)

    Palau, Patricia; Domínguez, Eloy; Núñez, Eduardo; Ramón, José María; López, Laura; Melero, Joana; Sanchis, Juan; Bellver, Alejandro; Santas, Enrique; Bayes-Genis, Antoni; Chorro, Francisco J; Núñez, Julio

    2018-04-01

    Heart failure with preserved ejection fraction (HFpEF) is a highly prevalent syndrome with an elevated risk of morbidity and mortality. To date, there is scarce evidence on the role of peak exercise oxygen uptake (peak VO 2 ) for predicting the morbidity burden in HFpEF. We sought to evaluate the association between peak VO 2 and the risk of recurrent hospitalizations in patients with HFpEF. A total of 74 stable symptomatic patients with HFpEF underwent a cardiopulmonary exercise test between June 2012 and May 2016. A negative binomial regression method was used to determine the association between the percentage of predicted peak VO 2 (pp-peak VO 2 ) and recurrent hospitalizations. Risk estimates are reported as incidence rate ratios. The mean age was 72.5 ± 9.1 years, 53% were women, and all patients were in New York Heart Association functional class II to III. Mean peak VO 2 and median pp-peak VO 2 were 10 ± 2.8mL/min/kg and 60% (range, 47-67), respectively. During a median follow-up of 276 days [interquartile range, 153-1231], 84 all-cause hospitalizations in 31 patients (41.9%) were registered. A total of 15 (20.3%) deaths were also recorded. On multivariate analysis, accounting for mortality as a terminal event, pp-peak VO 2 was independently and linearly associated with the risk of recurrent admission. Thus, and modeled as continuous, a 10% decrease of pp-peak VO 2 increased the risk of recurrent hospitalizations by 32% (IRR, 1.32; 95%CI, 1.03-1.68; P = .028). In symptomatic elderly patients with HFpEF, pp-peak VO 2 predicts all-cause recurrent admission. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  9. Preliminary observations in systemic oxygen consumption during targeted temperature management after cardiac arrest.

    Science.gov (United States)

    Uber, Amy; Grossestreuer, Anne V; Ross, Catherine E; Patel, Parth V; Trehan, Ambica; Donnino, Michael W; Berg, Katherine M

    2018-06-01

    Limited data suggests low oxygen consumption (VO 2 ), driven by mitochondrial injury, is associated with mortality after cardiac arrest. Due to the challenges of measurement in the critically ill, post-arrest metabolism remains poorly characterized. We monitored VO 2 , carbon dioxide production (VCO 2 ) and the respiratory quotient (RQ) in post-arrest patients and explored associations with outcome. Using a gas exchange monitor, we measured continuous VO 2 and VCO 2 in post- arrest patients treated with targeted temperature management. We used area under the curve and medians over time to evaluate the association between VO 2 , VCO 2 , RQ and the VO 2 :lactate ratio with survival. In 17 patients, VO 2 in the first 12 h after return of spontaneous circulation (ROSC) was associated with survival (median in survivors 3.35 mL/kg/min [2.98,3.88] vs. non-survivors 2.61 mL/kg/min [2.21,2.94], p = .039). This did not persist over 24 h. The VO 2 :lactate ratio was associated with survival (median in survivors 1.4 [IQR: 1.1,1.7] vs. non-survivors 0.8 [IQR: 0.6,1.2] p  0.7 (p = .131). VCO 2 was not associated with survival. There was a significant association between VO 2 and mortality in the first 12 h after ROSC, but not over 24 h. Lower VO 2: lactate ratio was associated with mortality. A large percentage of patients had RQs below physiologic norms. Further research is needed to explore whether these parameters could have true prognostic value or be a potential treatment target. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Effect of wearing clothes on oxygen uptake and ratings of perceived exertion while swimming.

    Science.gov (United States)

    Choi, S W; Kurokawa, T; Ebisu, Y; Kikkawa, K; Shiokawa, M; Yamasaki, M

    2000-07-01

    For a comparative study between swimming in swimwear (control-sw) and swimming in clothes (clothes-sw), oxygen uptake (VO2) and ratings of perceived exertion (RPE) were measured. The subjects were six male members of a university swimming team. Three swimming strokes--the breaststroke, the front crawl stroke and the elementary backstroke--were applied. With regards to clothes-sw, swimmers wore T-shirts, sportswear (shirt and pants) over swimwear and running shoes. In both cases of control-sw and clothes-sw, the VO2 was increased exponentially with increased swimming speed. The VO2 of the subjects during the clothed tests did not exceed 1.4 times of that in the case of control-sw at swimming speeds below 0.3 m/s. As swimming speeds increased, VO2 difference in both cases increased. Consequently, VO2 in the clothed tests was equal to 1.5-1.6 times and 1.5-1.8 times of that in the swimwear tests at speeds of 0.5 and 0.7 m/s, respectively. At speeds below 0.6 m/s in clothes-sw, the breaststroke showed lower VO2 than the front crawl stroke, and the elementary backstroke showed higher VO2 than the other two swimming strokes. RPE increased linearly with %peak VO2. In addition, any RPE differences among the three swimming strokes were not shown in the control-sw tests. At an exercise intensity above 60 %peak VO2, clothed swimmers showed slightly higher RPE in the front crawl stroke compared to that in the two other swimming strokes.

  11. Critical evaluation of oxygen-uptake assessment in swimming.

    Science.gov (United States)

    Sousa, Ana; Figueiredo, Pedro; Pendergast, David; Kjendlie, Per-Ludvik; Vilas-Boas, João P; Fernandes, Ricardo J

    2014-03-01

    Swimming has become an important area of sport science research since the 1970s, with the bioenergetic factors assuming a fundamental performance-influencing role. The purpose of this study was to conduct a critical evaluation of the literature concerning oxygen-uptake (VO2) assessment in swimming, by describing the equipment and methods used and emphasizing the recent works conducted in ecological conditions. Particularly in swimming, due to the inherent technical constraints imposed by swimming in a water environment, assessment of VO2max was not accomplished until the 1960s. Later, the development of automated portable measurement devices allowed VO2max to be assessed more easily, even in ecological swimming conditions, but few studies have been conducted in swimming-pool conditions with portable breath-by-breath telemetric systems. An inverse relationship exists between the velocity corresponding to VO2max and the time a swimmer can sustain it at this velocity. The energy cost of swimming varies according to its association with velocity variability. As, in the end, the supply of oxygen (whose limitation may be due to central-O2 delivery and transportation to the working muscles-or peripheral factors-O2 diffusion and utilization in the muscles) is one of the critical factors that determine swimming performance, VO2 kinetics and its maximal values are critical in understanding swimmers' behavior in competition and to develop efficient training programs.

  12. Influence of cerebrovascular arteriosclerosis on cerebral oxygenation during exercise

    International Nuclear Information System (INIS)

    Nagayama, Osamu; Koike, Akira; Hoshimoto, Masayo; Yamaguchi, Kaori; Tajima, Akihiko; Goda, Ayumi; Uejima, Tokuhisa; Aizawa, Tadanori; Itoh, Haruki

    2007-01-01

    Although it is assumed that cerebral oxygenation during exercise is influenced by both cardiopulmonary function and cerebrovascular arteriosclerosis, the latter factor has not been fully clarified. In the present study the relationship between the degree of cerebrovascular arteriosclerosis and cerebral oxygenation during exercise was investigated. A total of 109 patients (69 patients with coronary artery disease, 40 patients with hypertensive heart disease) (61.7±9.7 years) performed a symptom-limited exercise test with respiratory gas measurements (CPX). From the respiratory gas analysis, peak O 2 uptake (VO 2 ), the slope of the increase in VO 2 to the increase in work rate (ΔVO 2 /ΔWR), and the slope of the increase in ventilation to the increase in CO 2 output (VE/VCO 2 slope) were calculated. Oxyhemoglobin (O 2 Hb) at the forehead was monitored using near-infrared spectroscopy. The brain ischemic score was counted based upon fluid-attenuated inversion recovery images of magnetic resonance imaging and expressed from 0 to 4. When compared with patients with a lower ischemic score ( 2 Hb during exercise (-1.08±2.7 vs 0.77±4.1 μmol/L, p=0.011). Of brain ischemic score, left ventricular ejection fraction, peak VO 2 , ΔVO 2 /ΔWR, and the VE/VCO 2 slope, ΔVO 2 /ΔWR was found to be the sole independent index determining cerebral O 2 Hb during exercise. The CPX parameters were also significantly related to the degree of cerebrovascular arteriosclerosis. Although cerebral oxygenation during exercise is mainly related to cardiopulmonary function, the degree of cerebrovascular arteriosclerosis partly influences cerebral oxygenation in patients with risk factors for atherosclerosis. (author)

  13. Oscillation of tissue oxygen index in non-exercising muscle during exercise.

    Science.gov (United States)

    Yano, T; Afroundeh, R; Shirakawa, K; Lian, C-S; Shibata, K; Xiao, Z; Yunoki, T

    2015-09-01

    The purpose of the present study was to examine how oscillation of tissue oxygen index (TOI) in non-exercising exercise is affected during high-intensity and low-intensity exercises. Three exercises were performed with exercise intensities of 30% and 70% peak oxygen uptake (Vo(2)peak) for 12 min and with exercise intensity of 70% Vo(2)peak for 30 s. TOI in non-exercising muscle (biceps brachii) during the exercises for 12 min was determined by nearinfrared spectroscopy. TOI in the non-exercising muscle during the exercises was analyzed by fast Fourier transform (FFT) to obtain power spectra density (PSD). The frequency at which maximal PSD appeared (Fmax) during the exercise with 70% Vo(2)peak for 12 min (0.00477 ± 0.00172 Hz) was significantly lower than that during the exercise with 30% Vo2peak for 12 min (0.00781 ± 0.00338 Hz). There were significant differences in blood pH and blood lactate between the exercise with 70% Vo(2)peak and the exercise with 30% Vo(2)peak. It is concluded that TOI in nonexercising muscle oscillates during low-intensity exercise as well as during high-intensity exercise and that the difference in Fmax between the two exercises is associated with the difference in increase in blood lactate derived from the exercise.

  14. For progress in natural science: Materials international investigations of structural phase transformation and THz properties across metal–insulator transition in VO2/Al2O3 epitaxial films

    Directory of Open Access Journals (Sweden)

    Mengmeng Yang

    2015-10-01

    Full Text Available Vanadium dioxide (VO2 epitaxial thin films on (0001-oriented Al2O3 substrates were prepared using radio frequency (RF magnetron sputtering techniques. To study the metal-insulator-transition (MIT mechanism and extend the applications of VO2 epitaxial films at terahertz (THz band, temperature-dependent X-ray diffraction (XRD and THz time domain spectroscopy of the VO2 epitaxial films were performed. Both the lattice constants and THz transmission exhibited a similar and sharp transition that was similar to that observed for the electrical resistance. Consequently, the MIT of the VO2/Al2O3 epitaxial films should be co-triggered by the structural phase transition and electronic transition. Moreover, the very large resistance change (on the order of ~103 and THz response (with a transmission modulation ratio of ~87% in the VO2/Al2O3 epitaxial heterostructures are promising for electrical switch and electro-optical device applications.

  15. Machine learning and statistical methods for the prediction of maximal oxygen uptake: recent advances.

    Science.gov (United States)

    Abut, Fatih; Akay, Mehmet Fatih

    2015-01-01

    Maximal oxygen uptake (VO2max) indicates how many milliliters of oxygen the body can consume in a state of intense exercise per minute. VO2max plays an important role in both sport and medical sciences for different purposes, such as indicating the endurance capacity of athletes or serving as a metric in estimating the disease risk of a person. In general, the direct measurement of VO2max provides the most accurate assessment of aerobic power. However, despite a high level of accuracy, practical limitations associated with the direct measurement of VO2max, such as the requirement of expensive and sophisticated laboratory equipment or trained staff, have led to the development of various regression models for predicting VO2max. Consequently, a lot of studies have been conducted in the last years to predict VO2max of various target audiences, ranging from soccer athletes, nonexpert swimmers, cross-country skiers to healthy-fit adults, teenagers, and children. Numerous prediction models have been developed using different sets of predictor variables and a variety of machine learning and statistical methods, including support vector machine, multilayer perceptron, general regression neural network, and multiple linear regression. The purpose of this study is to give a detailed overview about the data-driven modeling studies for the prediction of VO2max conducted in recent years and to compare the performance of various VO2max prediction models reported in related literature in terms of two well-known metrics, namely, multiple correlation coefficient (R) and standard error of estimate. The survey results reveal that with respect to regression methods used to develop prediction models, support vector machine, in general, shows better performance than other methods, whereas multiple linear regression exhibits the worst performance.

  16. COMPARISON OF OXYGEN UPTAKE KINETICS AND OXYGEN DEFICIT IN SEVERELY OVERWEIGHT AND NORMAL WEIGHT ADOLESCENT FEMALES

    Directory of Open Access Journals (Sweden)

    Mark Loftin

    2005-12-01

    Full Text Available The purpose of this study was to determine if differences in oxygen uptake kinetics and oxygen deficit existed between normal weight and severely overweight adolescent girls. Subjects included 10 normal weight and 8 severely overweight girls. The participants performed a leg cycling VO2 peak test and a constant load leg cycling test at 80% of the ventilatory threshold (T-vent. In the constant workload test O2 kinetics as indicated by Phase I (VO2 L at 20 sec and Phase II time constants (t were determined. Also, the O2 deficit (VO2 L was measured. As expected significant differences were noted in body composition and VO2 peak relative to mass with normal weight body mass averaging 55.3 ± 7.0 kg, severely overweight 90.5 ± 18.0 kg, % fat normal weight 27.3 ± 3.9%, severely overweight 49.7 ± 4.9% and VO2 peak (ml·kg-1·min-1 normal weight 32.0 ± 2.7 and severely overweight 22.0 ± 5.3. VO2 peak (l·min-1 and T-vent (%VO2 max were similar between groups. Results revealed similar O2 kinetic responses between groups; phase I kinetics normal weight 0.72 ± 0.15 L; severely overweight 0.75 ± 0.13L, phase II (t normal weight 41.5 ± 21.3 sec; severely overweight 33.9 ± 22.7 sec. However, the O2 deficit was significantly higher in the severely overweight (0.75 ± 0.15L when compared to the normal weight group (0.34 ± 0.13L. Correlations ranged from r = -0.15 to 0.51 between VO2 peak (L·min-1 or fat weight and phase I, t and O2 deficit. These data generally support previous research concerning the independence of O2 uptake response and body size

  17. Maximal exercise test is a useful method for physical capacity and oxygen consumption determination in streptozotocin-diabetic rats

    Directory of Open Access Journals (Sweden)

    Irigoyen Maria-Cláudia

    2007-12-01

    Full Text Available Abstract Background The aim of the present study was to investigate the relationship between speed during maximum exercise test (ET and oxygen consumption (VO2 in control and STZ-diabetic rats, in order to provide a useful method to determine exercise capacity and prescription in researches involving STZ-diabetic rats. Methods Male Wistar rats were divided into two groups: control (CG, n = 10 and diabetic (DG, n = 8. The animals were submitted to ET on treadmill with simultaneous gas analysis through open respirometry system. ET and VO2 were assessed 60 days after diabetes induction (STZ, 50 mg/Kg. Results VO2 maximum was reduced in STZ-diabetic rats (72.5 ± 1 mL/Kg/min-1 compared to CG rats (81.1 ± 1 mL/Kg/min-1. There were positive correlations between ET speed and VO2 (r = 0.87 for CG and r = 0.8 for DG, as well as between ET speed and VO2 reserve (r = 0.77 for CG and r = 0.7 for DG. Positive correlations were also obtained between measured VO2 and VO2 predicted values (r = 0.81 for CG and r = 0.75 for DG by linear regression equations to CG (VO2 = 1.54 * ET speed + 52.34 and DG (VO2 = 1.16 * ET speed + 51.99. Moreover, we observed that 60% of ET speed corresponded to 72 and 75% of VO2 reserve for CG and DG, respectively. The maximum ET speed was also correlated with VO2 maximum for both groups (CG: r = 0.7 and DG: r = 0.7. Conclusion These results suggest that: a VO2 and VO2 reserve can be estimated using linear regression equations obtained from correlations with ET speed for each studied group; b exercise training can be prescribed based on ET in control and diabetic-STZ rats; c physical capacity can be determined by ET. Therefore, ET, which involves a relatively simple methodology and low cost, can be used as an indicator of cardio-respiratory capacity in future studies that investigate the physiological effect of acute or chronic exercise in control and STZ-diabetic male rats.

  18. Maximal exercise test is a useful method for physical capacity and oxygen consumption determination in streptozotocin-diabetic rats

    Science.gov (United States)

    Rodrigues, Bruno; Figueroa, Diego M; Mostarda, Cristiano T; Heeren, Marcelo V; Irigoyen, Maria-Cláudia; De Angelis, Kátia

    2007-01-01

    Background The aim of the present study was to investigate the relationship between speed during maximum exercise test (ET) and oxygen consumption (VO2) in control and STZ-diabetic rats, in order to provide a useful method to determine exercise capacity and prescription in researches involving STZ-diabetic rats. Methods Male Wistar rats were divided into two groups: control (CG, n = 10) and diabetic (DG, n = 8). The animals were submitted to ET on treadmill with simultaneous gas analysis through open respirometry system. ET and VO2 were assessed 60 days after diabetes induction (STZ, 50 mg/Kg). Results VO2 maximum was reduced in STZ-diabetic rats (72.5 ± 1 mL/Kg/min-1) compared to CG rats (81.1 ± 1 mL/Kg/min-1). There were positive correlations between ET speed and VO2 (r = 0.87 for CG and r = 0.8 for DG), as well as between ET speed and VO2 reserve (r = 0.77 for CG and r = 0.7 for DG). Positive correlations were also obtained between measured VO2 and VO2 predicted values (r = 0.81 for CG and r = 0.75 for DG) by linear regression equations to CG (VO2 = 1.54 * ET speed + 52.34) and DG (VO2 = 1.16 * ET speed + 51.99). Moreover, we observed that 60% of ET speed corresponded to 72 and 75% of VO2 reserve for CG and DG, respectively. The maximum ET speed was also correlated with VO2 maximum for both groups (CG: r = 0.7 and DG: r = 0.7). Conclusion These results suggest that: a) VO2 and VO2 reserve can be estimated using linear regression equations obtained from correlations with ET speed for each studied group; b) exercise training can be prescribed based on ET in control and diabetic-STZ rats; c) physical capacity can be determined by ET. Therefore, ET, which involves a relatively simple methodology and low cost, can be used as an indicator of cardio-respiratory capacity in future studies that investigate the physiological effect of acute or chronic exercise in control and STZ-diabetic male rats. PMID:18078520

  19. Consumo máximo de oxígeno (vo2max en bomberos: revisión sistemática de estudios

    Directory of Open Access Journals (Sweden)

    Jimmy Rojas Quirós

    2013-07-01

    Full Text Available Consumo máximo de oxígeno (VO2max en bomberos: revisión sistemática de estudios. El trabajo de bombero es catalogada como una profesión de riesgo, con alto requerimiento físico; en los últimos años el bombero ha adquirido más competencias que la propia de apagar incendios, entre ellas las intervenciones en accidentes de tránsito, incidentes con materiales peligrosos, rescates, fuegos forestales, entre otros. La imagen del bombero tradicional ha dado paso a nuevos profesionales preparados para afrontar todo tipo de desastres por lo que se habla en la actualidad del bombero completo. El objetivo de este estudio fue revisar sistemáticamente la evidencia científica sobre los valores de consumo máximo de oxígeno (VO2max que presentan los bomberos. Se incluyeron un total de 19 estudios, publicados entre los años 2002 y 2012, de las bases de datos de EBSCOhost, SpringerLink, SPORTDiscus, Medline, Embase y Scielo; además de revistas como Journal of Sports Science & Medicine, Occupational Medicine y Psicothema. Se concluye con esta revisión, con base a los resultados de los estudios, que las diferentes poblaciones de bomberos, oscilan un VO2max de 39,20 a 58,21 ml/kg/min, que varía según la condición inicial que tienen los bomberos en los diferentes estudios que proponen los autores; en general se determina que un bombero debe poseer valores de VO2max por encima de los 43 ml/kg/min, lo cual es lo mínimo recomendable para al menos poseer una buena capacidad aeróbica que le permita desenvolverse en sus funciones básicas como bombero.

  20. Oxygen uptake and body composition after aquatic physical training in women with fibromyalgia: a randomized controlled trial.

    Science.gov (United States)

    Andrade, Carolina P; Zamunér, Antonio R; Forti, Meire; França, Thalita F; Tamburús, Nayara Y; Silva, Ester

    2017-10-01

    Aquatic physical training (APT) has been strongly recommended to improve symptoms in fibromyalgia syndrome (FMS). However, its effects on body composition and whether lean body mass (LBM) directly influences the aerobic functional capacity of this population are still not clear. To investigate whether APT can help improve body composition and increase the aerobic functional capacity in women with FMS, and whether oxygen uptake (VO2) related to LBM can better quantify the functional capacity of this population. Randomized controlled trial. The Federal University of São Carlos, São Paulo, Brazil. Fifty-four women with FMS were randomly assigned to trained group (TG, N.=27) or control group (CG, N.=27). All women underwent cardiopulmonary exercise test (CPET) to assess oxygen consumption at ventilatory anaerobic threshold (VAT) and at peak exercise, and also to assess body composition. The TG was submitted to APT program, held twice a week for 16 weeks. The exercise intensity was adapted throughout the sessions in order to keep heart rate and ratings of perceived exertion achieved at VAT. After APT, body composition was not significantly different between groups (TG and CG). In VAT only TG showed increased VO2 related to LBM, since in peak CPET, VO2 in absolute units, VO2 related to total body mass (TBM), VO2 related to LBM and power showed significant differences. Significant difference between VO2 related to TBM and VO2 related to baseline LBM and after 16 weeks of follow-up, both in VAT as in peak CPET in both groups. Significant difference between VO2 related to TBM and VO2 related to LBM at VAT and at peak CPET in both groups at baseline and after 16 weeks of follow-up was observed. APT with standardized intensities did not cause significant changes in body composition, but was effective in promoting increased VO2 at peak CPET in women with FMS. However, VO2 related to LBM more accurately reflected changes in aerobic functional capacity at VAT level after to

  1. Ambiguous Role of Growth-Induced Defects on the Semiconductor-to-Metal Characteristics in Epitaxial VO2/TiO2 Thin Films.

    Science.gov (United States)

    Mihailescu, Cristian N; Symeou, Elli; Svoukis, Efthymios; Negrea, Raluca F; Ghica, Corneliu; Teodorescu, Valentin; Tanase, Liviu C; Negrila, Catalin; Giapintzakis, John

    2018-04-25

    Controlling the semiconductor-to-metal transition temperature in epitaxial VO 2 thin films remains an unresolved question both at the fundamental as well as the application level. Within the scope of this work, the effects of growth temperature on the structure, chemical composition, interface coherency and electrical characteristics of rutile VO 2 epitaxial thin films grown on TiO 2 substrates are investigated. It is hereby deduced that the transition temperature is lower than the bulk value of 340 K. However, it is found to approach this value as a function of increased growth temperature even though it is accompanied by a contraction along the V 4+ -V 4+ bond direction, the crystallographic c-axis lattice parameter. Additionally, it is demonstrated that films grown at low substrate temperatures exhibit a relaxed state and a strongly reduced transition temperature. It is suggested that, besides thermal and epitaxial strain, growth-induced defects may strongly affect the electronic phase transition. The results of this work reveal the difficulty in extracting the intrinsic material response to strain, when the exact contribution of all strain sources cannot be effectively determined. The findings also bear implications on the limitations in obtaining the recently predicted novel semi-Dirac point phase in VO 2 /TiO 2 multilayer structures.

  2. Determinants of maximal oxygen uptake in severe acute hypoxia

    DEFF Research Database (Denmark)

    Calbet, J A L; Boushel, Robert Christopher; Rådegran, G

    2003-01-01

    To unravel the mechanisms by which maximal oxygen uptake (VO2 max) is reduced with severe acute hypoxia in humans, nine Danish lowlanders performed incremental cycle ergometer exercise to exhaustion, while breathing room air (normoxia) or 10.5% O2 in N2 (hypoxia, approximately 5,300 m above sea......: 1) reduction of PiO2, 2) impairment of pulmonary gas exchange, and 3) reduction of maximal cardiac output and peak leg blood flow, each explaining about one-third of the loss in VO2 max....

  3. Raman scattering and x-ray diffractometry studies of epitaxial TiO2 and VO2 thin films and multilayers on α-Al2O3(11 bar 20)

    International Nuclear Information System (INIS)

    Foster, C.M.; Chiarello, R.P.; Chang, H.L.M.; You, H.; Zhang, T.J.; Frase, H.; Parker, J.C.; Lam, D.J.

    1993-01-01

    Epitaxial thin films of TiO 2 and VO 2 single layers and TiO 2 /VO 2 multilayers were grown on (11 bar 20) sapphire (α-Al 2 O 3 ) substrates using the metalorganic chemical vapor deposition technique and were characterized using Raman scattering and four x-ray diffractometry. X-ray diffraction results indicate that the films are high quality single crystal material with well defined growth plane and small in-plane and out-of-plane mosaic. Single-layer films are shown to obey the Raman selection rules of TiO 2 and VO 2 single crystals. The close adherence to the Raman selection rules indicates the high degree of orientation of the films, both parallel and perpendicular to the growth plane. Selection rule spectra of two and three layer TiO 2 /VO 2 multilayers are dominated by the VO 2 layers with only minimal signature of the TiO 2 layers. Due to the low band gap of semiconducting vanadium dioxide, we attribute the strong signature of the VO 2 layers to resonant enhancement of the VO 2 Raman component accompanied with absorption of the both the incident and scattered laser light from the TiO 2 layers

  4. Response profiles of oxygen uptake efficiency during exercise in healthy children

    NARCIS (Netherlands)

    Bongers, Bart C.; Hulzebos, Erik H J; Helbing, Willem A.; Ten Harkel, Arend D J; Van Brussel, Marco; Takken, Tim

    2015-01-01

    Background Oxygen uptake efficiency (OUE), the relation between oxygen uptake (VO2) and minute ventilation (VE), differs between healthy children and children with heart disease. This study aimed to investigate the normal response profiles of OUE during a progressive cardiopulmonary exercise test.

  5. Oxygen-saving effect of a new cardiotonic agent, MCI-154, in diseased human hearts.

    Science.gov (United States)

    Mori, M; Takeuchi, M; Takaoka, H; Hata, K; Hayashi, Y; Yamakawa, H; Yokoyama, M

    1997-03-01

    The aim of this study was to examine the left ventricular mechanoenergetic effects of a novel Ca2+ sensitizing agent, MCI-154, on diseased human hearts compared with dobutamine. Unlike conventional cardiotonic agents, a Ca2+ sensitizer that could produce a positive inotropic action by altering the responsiveness of myofilament to Ca2+ could generate force with smaller amounts of Ca2+; thus, it may potentially save energy expenditure. The left ventricular pressure-volume relation and myocardial oxygen consumption per beat (Vo2) were measured by a conductance (volume) catheter and a Webster catheter. Left ventricular contractility (Emax), systolic pressure-volume area (PVA [index of left ventricular total mechanical energy]) and Vo2 were assessed before and after infusion of MCI-154 or dobut-amine. The PVA-independent Vo2 (Vo2 mainly for excitation-contraction coupling) was assessed as the Vo2 at zero PVA. Both agents increased Emax comparably (dobutamine: from 3.55 +/- 1.10 [mean +/- SD] to 5.04 +/- 1.16 mm Hg/ml per m2, p delta PVA-independent Vo2/delta Emax) was less with MCI-154 than with dobutamine (0.14 +/- 0.18 vs. 1.10 +/- 0.80 J/mm Hg per ml per m2, p action mediated by MCI-154 could provide an energetic advantage over the conventional cardiotonic action with currently used inotropic agents.

  6. THE CONTRIBUTION OF 'RESTING' BODY MUSCLES TO THE SLOW COMPONENT OF PULMONARY OXYGEN UPTAKE DURING HIGH-INTENSITY CYCLING

    Directory of Open Access Journals (Sweden)

    Susan A. Ward

    2012-12-01

    Full Text Available Oxygen uptake (VO2 kinetics during moderate constant- workrate (WR exercise (>lactate-threshold (ӨL are well described as exponential. AboveӨL, these kinetics are more complex, consequent to the development of a delayed slow component (VO2sc, whose aetiology remains controversial. To assess the extent of the contribution to the VO2sc from arm muscles involved in postural stability during cycling, six healthy subjects completed an incremental cycle-ergometer test to the tolerable limit for estimation of ӨL and determination of peak VO2. They then completed two constant-WR tests at 90% of ӨL and two at 80% of ∆ (difference between ӨL and VO2peak. Gas exchange variables were derived breath-by-breath. Local oxygenation profiles of the vastus lateralis and biceps brachii muscles were assessed by near-infrared spectroscopy, with maximal voluntary contractions (MVC of the relevant muscles being performed post-exercise to provide a frame of reference for normalising the exercise-related oxygenation responses across subjects. Above supra-ӨL, VO2 rose in an exponential-like fashion ("phase 2, with a delayed VO2sc subsequently developing. This was accompanied by an increase in [reduced haemoglobin] relative to baseline (∆[Hb], which attained 79 ± 13 % (mean, SD of MVC maximum in vastus lateralis at end-exercise and 52 ± 27 % in biceps brachii. Biceps brachii ∆[Hb] was significantly correlated with VO2 throughout the slow phase. In contrast, for sub- L exercise, VO2 rose exponentially to reach a steady state with a more modest increase in vastus lateralis ∆[Hb] (30 ± 11 %; biceps brachii ∆[Hb] was minimally affected (8 ± 2 %. That the intramuscular O2 desaturation profile in biceps brachii was proportional to that for VO2sc during supra-ӨL cycle ergometry is consistent with additional stabilizing arm work contributing to the VO2sc

  7. Physical activity as a long-term predictor of peak oxygen uptake: the HUNT Study.

    Science.gov (United States)

    Aspenes, Stian Thoresen; Nauman, Javaid; Nilsen, Tom Ivar Lund; Vatten, Lars Johan; Wisløff, Ulrik

    2011-09-01

    A physically active lifestyle and a relatively high level of cardiorespiratory fitness are important for longevity and long-term health. No population-based study has prospectively assessed the association of physical activity levels with long-term peak oxygen uptake (VO(2peak)). 1843 individuals (906 women and 937 men) who were between 18 and 66 yr at baseline and were free from known lung or heart diseases at both baseline (1984-1986) and follow-up (2006-2008) were included in the study. Self-reported physical activity was recorded at both occasions, and VO(2peak) was measured at follow-up. The association of physical activity levels and VO(2peak) was adjusted for age, level of education, smoking status, and weight change from baseline to follow-up, using ANCOVA statistics. The level of physical activity at baseline was strongly associated with VO(2peak) at follow-up 23 yr later in both men and women (Ptrends active at baseline had higher (3.3 and 4.6 mL·kg(-1)·min(-1)) VO(2peak) at follow-up. Women who were inactive at baseline but highly active at follow-up had 3.7 mL·kg(-1)·min(-1) higher VO(2peak) compared with women who were inactive both at baseline and at follow-up. The corresponding comparison in men showed a difference of 5.2 mL·kg(-1)·min(-1) (95% confidence interval = 3.1-7.3) in VO(2peak). Physical activity level at baseline was positively associated with directly measured cardiorespiratory fitness (VO(2peak)) 23 yr later. People who changed from low to high activity during the observation period had substantially higher V˙O(2peak) at follow-up compared with people whose activity remained low.

  8. Increased cardiac output and maximal oxygen uptake in response to ten sessions of high intensity interval training.

    Science.gov (United States)

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael M; Namm, Samantha; Fischer, Anthony; Wood, Kimi A

    2018-01-01

    Increases in maximal oxygen uptake (VO2max) are widely reported in response to completion of high intensity interval training (HIIT), yet the mechanism explaining this result is poorly understood. This study examined changes in VO2max and cardiac output (CO) in response to 10 sessions of low-volume HIIT. Participants included 30 active men and women (mean age and VO2max=22.9±5.4 years and 39.6±5.6 mL/kg/min) who performed HIIT and 30 men and women (age and VO2max=25.7±4.5 years and 40.7±5.2 mL/kg/min) who served as non-exercising controls (CON). High intensity interval training consisted of 6-10 s bouts of cycling per session at 90-110 percent peak power output (PPO) interspersed with 75 s recovery. Before and after training, progressive cycling to exhaustion was completed during which CO, stroke volume (SV), and heart rate (HR) were estimated using thoracic impedance. To confirm VO2max attainment, a verification test was completed after progressive cycling at a work rate equal to 110%PPO. Data demonstrated significant improvements in VO2max (2.71±0.63 L/min to 2.86±0.63 L/min, Psessions of HIIT is due to improvements in oxygen delivery.

  9. Submaximal oxygen uptake kinetics, functional mobility, and physical activity in older adults with heart failure and reduced ejection fraction.

    Science.gov (United States)

    Hummel, Scott L; Herald, John; Alpert, Craig; Gretebeck, Kimberlee A; Champoux, Wendy S; Dengel, Donald R; Vaitkevicius, Peter V; Alexander, Neil B

    2016-07-01

    Submaximal oxygen uptake measures are more feasible and may better predict clinical cardiac outcomes than maximal tests in older adults with heart failure (HF). We examined relationships between maximal oxygen uptake, submaximal oxygen kinetics, functional mobility, and physical activity in older adults with HF and reduced ejection fraction. Older adults with HF and reduced ejection fraction (n = 25, age 75 ± 7 years) were compared to 25 healthy age- and gender-matched controls. Assessments included a maximal treadmill test for peak oxygen uptake (VO2peak), oxygen uptake kinetics at onset of and on recovery from a submaximal treadmill test, functional mobility testing [Get Up and Go (GUG), Comfortable Gait Speed (CGS), Unipedal Stance (US)], and self-reported physical activity (PA). Compared to controls, HF had worse performance on GUG, CGS, and US, greater delays in submaximal oxygen uptake kinetics, and lower PA. In controls, VO2peak was more strongly associated with functional mobility and PA than submaximal oxygen uptake kinetics. In HF patients, submaximal oxygen uptake kinetics were similarly associated with GUG and CGS as VO2peak, but weakly associated with PA. Based on their mobility performance, older HF patients with reduced ejection fraction are at risk for adverse functional outcomes. In this population, submaximal oxygen uptake measures may be equivalent to VO2 peak in predicting functional mobility, and in addition to being more feasible, may provide better insight into how aerobic function relates to mobility in older adults with HF.

  10. An electrochemical study of the systems Li1+-xV2O4 and Li1-xVO2 (0≤x≤1)

    International Nuclear Information System (INIS)

    De Picciotto, L.A.; Thackeray, M.M.; Pistoia, G.

    1988-01-01

    Electrochemical properties of the systems Li 1±x V 2 O 4 (0≤x≤1), Li 1-x VO 2 (0≤x 2 O 4 is reversible, which confirms that lithium may be cycled, topotactically, in and out of the Li 1+x V 2 O 4 spinel structure. Delithiation of the LiV 2 O 4 spinel is irreversible; during this process the vanadium ions migrate through the oxide layers. This results in a defect rocksalt phase, which can, in turn, be relithiated by a different mechanism. Lithium extraction for the layered compound LiVO 2 yields a structure similar to the delithiated LiV 2 O 4 product. The spinel-derived compounds Li 1 +-x/V 2 O 4 (0 -3 Ω -1 cm -1 at x=0 and 10 -6 Ω -1 cm -1 at x=1. Lithium diffusion rates in Li 1±x V 2 O 4 samples increase with lithiation from D=4x10 -10 cm 2 /s in LiV 2 O 4 to D=6x10 -8 cm 2 /s in Li 2 V 2 O 4 . Intermediate values of D are obtained in the delithiated compound Li 0.28 V 2 O 4 and in the layered oxide LiVO 2 ; significantly lower values of D, viz. 1x10 -11 cm 2 /s and 4x10 -11 cm 2 /s , are found in the spinels LiMn 2 O 4 and Fe 3 O 4 respectively. 28 refs.; 5 figs.; 1 table

  11. Observation of the spin gap in a S=1/2 alternating chain compound, high pressure phase of (VO)2P2O7

    International Nuclear Information System (INIS)

    Saito, Takashi; Azuma, Masaki; Fujita, Masaki; Takano, Mikio

    2001-01-01

    Inelastic neutron scattering data were collected on the high pressure phase of (VO) 2 P 2 O 7 , a S=1/2 Heisenberg antiferromagnetic alternating chain compound. The existence of a spin gap was confirmed, and the size was determined to be Δ=2.15(6) meV (=25.0(7) K). The theoretically predicted second gap (Δ'=2Δ) owing to a 2-magnon bound state was not observed. This is consistent with the high field magnetization measurement reported previously. (author)

  12. High-intensity interval training improves VO2peak, maximal lactate accumulation, time trial and competition performance in 9?11-year-old swimmers

    OpenAIRE

    Sperlich, Billy; Zinner, Christoph; Heilemann, Ilka; Kjendlie, Per-Ludvik; Holmberg, Hans-Christer; Mester, Joachim

    2010-01-01

    Training volume in swimming is usually very high when compared to the relatively short competition time. High-intensity interval training (HIIT) has been demonstrated to improve performance in a relatively short training period. The main purpose of the present study was to examine the effects of a 5-week HIIT versus high-volume training (HVT) in 9?11-year-old swimmers on competition performance, 100 and 2,000?m time (T 100?m and T 2,000?m), VO2peak and rate of maximal lactate accumulation (La...

  13. Survey of Synergistic Effect of L-carnitine with Glutamine on Body Composition and Dietary Intake in Soccer Players: A Double-blind, Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Hozoori

    2016-10-01

    Full Text Available Background: The present study was conducted to investigate the possible effects of L-carnitine and glutamine and their synergistic effects on male soccer athletes. Methods: 28 male soccer players (21.1 ± 0.7 y were enrolled in a randomized pre and post intervention, double-blind design. Before the intervention, their performances were assessed by Bruce protocol, and their body composition was measured with the body composition analyzer. Then, athletes were randomly allocated into four groups: 2 g L-glutamine, 2 g L-carnitine, 2 g L-carnitine + 2 g L-glutamine and placebo. Supplements were prescribed for 21 days and after three weeks, athletes' performances and body composition were re-evaluated. Results: The results showed that body weight, body fat percentage, lean muscle mass, and dietary intake made no significant changes in different groups of athletes. In between groups comparison, results did not significantly change in any performance indices. However, in L-carnitine supplement group, the results of pre and post intervention showed that the running distance and maximal oxygen uptake (VO2max increased significantly while the subjective sense of fatigue decreased significantly. Conclusions: Based on our findings, a three-week prescription of separateor combined glutamine and L-carnitine, had no effects on body composition or dietary intake in soccer players. But, the athletes' energy intake was more than the one reported in other studies. Although further studies are required to assess these effects on athletic performance.

  14. Oxygen uptake response to cycle ergometry in post-acute stroke patients with different severity of hemiparesis.

    Science.gov (United States)

    Chen, Chun-Kai; Weng, Ming-Cheng; Chen, Tien-Wen; Huang, Mao-Hsiung

    2013-11-01

    This study evaluated the impact of severity of hemiparesis on oxygen uptake (VO2) response in post-acute stroke patients. Sixty-four patients with a mean poststroke interval of 8.6 ± 3.8 days underwent a ramp cardiopulmonary exercise test on a cycling ergometer to volitional termination. Mean peak VO2 (VO2peak) and work efficiency (ΔVO2/ΔWR) were measured by open-circuit spirometry during standard upright ergometer cycling. Severity of the hemiparetic lower limb was assessed by Brunnstrom's motor recovery stages lower extremity (BMRSL). VO2peak was 10% lower in hemiparetic leg with BMRSL V than in that with BMRSL VI, 20% lower in BMRSL IV, and 50% lower in BMRSL III. ΔVO2/ΔWR was higher for the group with increased BMRSL. The relations were consistent after adjustment for age, sex, body mass index, stroke type, hemiparetic side, modified Ashworth Scale, time poststroke, comorbidities, and medications. Our findings revealed that O2peak is dependent on the severity of hemiparesis in leg, and along with ΔO2/ΔWR closely related to the severity of hemiparesis in post-acute stroke patients, regardless of the types and locations of lesion after stroke, as well as the differences in comorbidities and medications. Copyright © 2013. Published by Elsevier B.V.

  15. Relationship between oxygen uptake slow component and surface EMG during heavy exercise in humans: influence of pedal rate.

    Science.gov (United States)

    Vercruyssen, Fabrice; Missenard, Olivier; Brisswalter, Jeanick

    2009-08-01

    The aim of this study was to test the hypothesis that extreme pedal rates contributed to the slow component of oxygen uptake (VO(2) SC) in association with changes in surface electromyographic (sEMG) during heavy-cycle exercise. Eight male trained cyclists performed two square-wave transitions at 50 and 110 rpm at a work rate that would elicit a VO(2) corresponding to 50% of the difference between peak VO(2) and the ventilatory threshold. Pulmonary gas exchange was measured breath-by-breath and sEMG was obtained from the vastus lateralis and medialis muscles. Integrated EMG flow (QiEMG) and mean power frequency (MPF) were computed. The relative amplitude of the VO(2) SC was significantly higher during the 110-rpm bout (556+/-186 ml min(-1), Pexercise only during the 110-rpm bout and were associated with the greater amplitude of the VO(2) SC observed for this condition (Pmotor units recruitment pattern, muscle energy turnover and muscle temperature have been suggested to explain the different VO(2) SC to heavy pedal rate bouts.

  16. Influence of VO2+ ions on structural and optical properties of potassium succinate-succinic acid single crystal for non-linear optical applications

    Science.gov (United States)

    Juliet sheela, K.; Subramanian, P.

    2018-04-01

    A transparent and good optical quality semi organic single crystal of vanadium doped potassium succinate-succinic acid (KSSA) was synthesized by slow evaporation technique at room temperature. The structural perfection was supported by the powder XRD of the KSSA-VO2+ single crystal. Optical behavior of the material was discovered from the absorption and transmission spectra of UV-vis-NIR characterization. Functional group and presence of metal ion in the specimen are depicted from FTIR traces. From the photoluminescence studies, emission of wavelength in the violet region (418 nm) at the excitation of 243 nm could be ascertained. EDAX, SEM measurements identify presence of elements and pictures the step-line growth and the imperfection presents in the grown crystal. EPR analysis extracts the information about the local site symmetry around the impurity ion, molecular orbital coefficients, admixture coefficients and ground state wave function of VO2+ doped KSSA single crystal. Second harmonic generation (SHG) efficiency of the grown crystal was investigated to explore the NLO characteristic of the material.

  17. Nature of phase transitions in ammonium oxofluorovanadates, a vibrational spectroscopy study of (NH4)3VO2F4 and (NH4)3VOF5.

    Science.gov (United States)

    Gerasimova, Yu V; Oreshonkov, A S; Laptash, N M; Vtyurin, A N; Krylov, A S; Shestakov, N P; Ershov, A A; Kocharova, A G

    2017-04-05

    Two ammonium oxofluorovanadates, (NH 4 ) 3 VO 2 F 4 and (NH 4 ) 3 VOF 5 , have been investigated by temperature-dependent infrared and Raman spectroscopy methods to determine the nature of phase transitions (PT) in these compounds. Dynamics of quasioctahedral groups was simulated within the framework of semi-empirical approach, which justified the cis-conformation of VO 2 F 4 3- (C 2v ) and the C 4v geometry of VOF 5 3- . The observed infrared and Raman spectra of both compounds at room temperature (RT) revealed the presence at least of two crystallographically independent octahedral groups. The first order PT at elevated temperatures is connected with a complete dynamic disordering of these groups with only single octahedral state. At lower temperatures, the octahedra are ordered and several octahedral states appear. This PT is the most pronounced in the case of (NH 4 ) 3 VOF 5 , when at least seven independent VOF 5 3- octahedra are present in the structure below 50K, in accordance with the Raman spectra. Ammonium groups do not take part in PTs at higher and room temperatures but their reorientational motion freezes at lower temperatures. Copyright © 2017. Published by Elsevier B.V.

  18. Training induced decrease in oxygen cost of cycling is accompanied by down-regulation of SERCA expression in human vastus lateralis muscle.

    Science.gov (United States)

    Majerczak, J; Karasinski, J; Zoladz, J A

    2008-09-01

    We have examined the effect of 5 week cycling endurance training program on the sarco(endo)plasmic reticulum Ca2+ ATPase isoforms (SERCA1 and 2) and myosin heavy chain (MyHC) in the vastus lateralis muscle as well as on the oxygen uptake to power output ratio (VO2/PO) during incremental cycling. Fifteen untrained men performed an incremental cycling exercise until exhaustion before and after moderate intensity training. Muscle biopsies were taken from vastus lateralis before and after training program. Training resulted in higher (P = 0.048) maximal oxygen uptake (VO(2max)) as well as in higher power output reached at VO(2max) (P = 0.0001). Moreover, lower (P = 0.02) VO2/PO ratio determined during incremental moderate intensity cycling (i.e. 30-120 W) as well as lower (P = 0.003) VO2/PO ratio reached at VO(2max) were observed after the training. A significant down regulation of SERCA2 protein (P = 0.03) and tendency (P = 0.055) to lower SERCA1 content accompanied by lower (P<10(-4)) plasma thyroid hormone concentration, with no changes (P = 0.67) in MyHC composition in vastus lateralis muscle were found after training. We have concluded that the increase in mechanical efficiency of cycling occurring during first weeks of endurance training is not related to changes in MyHC composition but it may be due to down-regulation of SERCA pumps.

  19. Oxygen pressure manipulations on the metal-insulator transition characteristics of highly (011)-oriented vanadium dioxide films grown by magnetron sputtering

    International Nuclear Information System (INIS)

    Yu Qian; Li Wenwu; Duan Zhihua; Hu Zhigao; Chu Junhao; Liang Jiran; Chen Hongda; Liu Jian

    2013-01-01

    The metal-insulator transition behaviour of vanadium dioxide (VO 2 ) films grown at different oxygen pressures is investigated. With the aid of temperature-dependent electrical and infrared transmittance experiments, it is found that the transition temperature in the heating process goes up with increasing argon-oxygen ratio, whereas the one in the cooling process shows an inverse variation trend. It is found that the hysteresis width of the phase transition is narrowed at a lower argon-oxygen ratio because the defects introduced by excess oxygen lower the energy requirement of transformation. Furthermore, the defects reduce the forbidden gap of the VO 2 system due to the generation of a V 5+ ion. The present results are valuable for the achievement of VO 2 -based optoelectronic devices.

  20. Using carbon emissions, oxygen consumption, and energy retention estimates to calculate dietary energy partitioning and estimate forage intake by beef steers

    Science.gov (United States)

    Take home Message: Estimating ME intake by grazing cattle seems possible using respiration gas exchange estimates. Introduction: We hypothesized that carbon dioxide, methane, and oxigen exchange estimates in breath clouds could be used as biomarkers to ultimately estimate dry matter intake in grazi...

  1. THE COMBINATION OF α-LIPOIC ACID INTAKE WITH ECCENTRIC EXERCISE MODULATES ERYTHROPOIETIN RELEASE

    Directory of Open Access Journals (Sweden)

    B. Morawin

    2014-08-01

    Full Text Available The generation of reactive nitrogen/oxygen species (RN/OS represents an important mechanism in erythropoietin (EPO expression and skeletal muscle adaptation to physical and metabolic stress. RN/OS generation can be modulated by intense exercise and nutrition supplements such as α-lipoic acid, which demonstrates both anti- and pro-oxidative action. The study was designed to show the changes in the haematological response through the combination of α-lipoic acid intake with running eccentric exercise. Sixteen healthy young males participated in the randomised and placebo-controlled study. The exercise trial involved a 90-min run followed by a 15-min eccentric phase at 65% VO2max (-10% gradient. It significantly increased serum concentrations of nitric oxide (NO, hydrogen peroxide (H2O2 and pro-oxidative products such as 8-isoprostanes (8-iso, lipid peroxides (LPO and protein carbonyls (PC. α-Lipoic acid intake (Thiogamma: 1200 mg daily for 10 days prior to exercise resulted in a 2-fold elevation of serum H2O2 concentration before exercise, but it prevented the generation of NO, 8-iso, LPO and PC at 20 min, 24 h, and 48 h after exercise. α-Lipoic acid also elevated serum EPO level, which highly correlated with NO/H2O2 ratio (r=0.718, P<0.01. Serum total creatine kinase (CK activity, as a marker of muscle damage, reached a peak at 24 h after exercise (placebo 732 ± 207 IU · L-1, α-lipoic acid 481 ± 103 IU · L-1, and correlated with EPO (r = 0.478, P<0.01 in the α-lipoic acid group. In conclusion, the intake of high α-lipoic acid modulates RN/OS generation, enhances EPO release and reduces muscle damage after running eccentric exercise.

  2. Measurement of oxygen consumption with the Cosmed K2: a comparative study

    NARCIS (Netherlands)

    Forkink, A.; Frings-Dresen, M. H.

    1994-01-01

    An instrument that accurately measures oxygen consumption (VO2) during field performance is valuable for investigations of physiological workload. Cosmed (Rome, Italy) has introduced such an instrument, the Cosmed K2. In this study the Cosmed K2 was compared with the Oxyconbeta (Jaeger, Breda, The

  3. Effects of Hemopure on maximal oxygen uptake and endurance performance in healthy humans.

    Science.gov (United States)

    Ashenden, M J; Schumacher, Y O; Sharpe, K; Varlet-Marie, E; Audran, M

    2007-05-01

    Haemoglobin-based oxygen carriers (HBOCs) such as Hemopure are touted as a tenable substitute for red blood cells and therefore potential doping agents, although the mechanisms of oxygen transport of HBOCs are incompletely understood. We investigated whether infusion of Hemopure increased maximal oxygen uptake (V.O 2max) and endurance performance in healthy subjects. Twelve male subjects performed two 4-minute submaximal exercise bouts equivalent to 60 % and 75 % of V.O (2max) on a cycle ergometer, followed by a ramped incremental protocol to elicit V.O (2max). A crossover design tested the effect of infusing either 30 g (6 subjects) or 45 g (6 subjects) of Hemopure versus a placebo. Under our study conditions, Hemopure did not increase V.O (2max) nor endurance performance. However, the infusion of Hemopure caused a decrease in heart rate of approximately 10 bpm (p=0.009) and an average increase in mean ( approximately 7 mmHg) and diastolic blood pressure ( approximately 8 mmHg) (p=0.046) at submaximal and maximal exercise intensities. Infusion of Hemopure did not bestow the same physiological advantages generally associated with infusion of red blood cells. It is conceivable that under exercise conditions, the hypertensive effects of Hemopure counter the performance-enhancing effect of improved blood oxygen carrying capacity.

  4. Theoretical studies of the optical and EPR spectra for VO^{2+} in Na_3C_6H_5O_7·2H_2O single crystal

    Directory of Open Access Journals (Sweden)

    Ch.-Y. Li

    2015-06-01

    Full Text Available On the basis of the perturbation formulas for a d^1 configuration ion in a tetragonal crystal field, the three optical absorption bands and electron paramagnetic resonance (EPR parameters (g factors g_i and hyperfine structure constants A_i for i = || and ⊥, respectively of VO^{2+} in Na_3C_6H_5O_7·2H_2O (TSCD single crystals were studied using the perturbation theory method. By simulating the calculated optical and EPR spectra to the observed values, local structure parameters and negative signs of the hyperfine structure constants A_i of the octahedral (VO_6^{8-} cluster in TSCD single crystal can be obtained.

  5. Relação entre a variabilidade da frequência cardíaca e VO 2pico em mulheres ativas

    OpenAIRE

    Tamburús, Nayara Yamada; Rebelo, Ana Cristina Silva; César, Marcelo de Castro; Catai, Aparecida Maria; Takahashi, Anielle Cristhine de Medeiros; Andrade, Carolina Pieroni; Porta, Alberto; Silva, Ester da

    2014-01-01

    OBJETIVO: Ava+liar a associação entre os índices da variabilidade da frequência cardíaca (VFC) e a aptidão cardiorrespiratória.MÉTODOS: Sessenta e duas mulheres (idade 22,1 ± 3,3 anos) foram divididas em quatro grupos: treinamento aeróbio (AER, n = 15), treinamento de força (FOR, n = 13), treinamento combinado (aeróbio e força) (AER+FOR, n = 15) e controle (C, n = 19). O teste cardiopulmonar foi realizado para avaliar a aptidão cardiorrespiratória a partir do consumo de oxigênio pico (VO2pico...

  6. Self Assembly and Properties of C:WO3 Nano-Platelets and C:VO2/V2O5 Triangular Capsules Produced by Laser Solution Photolysis

    Directory of Open Access Journals (Sweden)

    Sideras-Haddad E

    2009-01-01

    Full Text Available Abstract Laser photolysis of WCl6 in ethanol and a specific mixture of V2O5 and VCl3 in ethanol lead to carbon modified vanadium and tungsten oxides with interesting properties. The presence of graphene’s aromatic rings (from the vibrational frequency of 1,600 cm−1 together with C–C bonding of carbon (from the Raman shift of 1,124 cm−1 present unique optical, vibrational, electronic and structural properties of the intended tungsten trioxide and vanadium dioxide materials. The morphology of these samples shows nano-platelets in WO x samples and, in VO x samples, encapsulated spherical quantum dots in conjunction with fullerenes of VO x . Conductivity studies revealed that the VO2/V2O5 nanostructures are more sensitive to Cl than to the presence of ethanol, whereas the C:WO3 nano-platelets are more sensitive to ethanol than atomic C.

  7. Imaging Nanometer Phase Coexistence at Defects During the Insulator-Metal Phase Transformation in VO2 Thin Films by Resonant Soft X-ray Holography.

    Science.gov (United States)

    Vidas, Luciana; Günther, Christian M; Miller, Timothy A; Pfau, Bastian; Perez-Salinas, Daniel; Martínez, Elías; Schneider, Michael; Gührs, Erik; Gargiani, Pierluigi; Valvidares, Manuel; Marvel, Robert E; Hallman, Kent A; Haglund, Richard F; Eisebitt, Stefan; Wall, Simon

    2018-05-18

    We use resonant soft X-ray holography to image the insulator-metal phase transition in vanadium dioxide with element and polarization specificity and nanometer spatial resolution. We observe that nanoscale inhomogeneity in the film results in spatial-dependent transition pathways between the insulating and metallic states. Additional nanoscale phases form in the vicinity of defects which are not apparent in the initial or final states of the system, which would be missed in area-integrated X-ray absorption measurements. These intermediate phases are vital to understand the phase transition in VO 2 , and our results demonstrate how resonant imaging can be used to understand the electronic properties of phase-separated correlated materials obtained by X-ray absorption.

  8. Self assembly and properties of C:WO3 nano-platelets and C:VO2/V2O5 triangular capsules produced by laser solution photolysis

    CSIR Research Space (South Africa)

    Mwakikunga, BW

    2010-01-01

    Full Text Available -Structured Materials, P. O. Box 395, Pretoria, South Africa 123 Nanoscale Res Lett (2010) 5:389–397 DOI 10.1007/s11671-009-9494-4 coherent, intense and almost monochromatic laser light allows it to be tuned to selectively dissociate specific bonds in a precursor... in the current set of experiments. 390 Nanoscale Res Lett (2010) 5:389–397 123 2WðO � C2H5Þ6��! 248nm CxWO3�y þ . . . 2VðO � C2H5Þ4��! 248nm CxVO2þy þ . . . ð3Þ When the same precursors are irradiated with the 248-nm beam from the KrF excimer laser, the W(OR)6...

  9. Comparison of structured and unstructured physical activity training on predicted VO2max and heart rate variability in adolescents - a randomized control trial.

    Science.gov (United States)

    Sharma, Vivek Kumar; Subramanian, Senthil Kumar; Radhakrishnan, Krishnakumar; Rajendran, Rajathi; Ravindran, Balasubramanian Sulur; Arunachalam, Vinayathan

    2017-05-01

    Physical inactivity contributes to many health issues. The WHO-recommended physical activity for adolescents encompasses aerobic, resistance, and bone strengthening exercises aimed at achieving health-related physical fitness. Heart rate variability (HRV) and maximal aerobic capacity (VO2max) are considered as noninvasive measures of cardiovascular health. The objective of this study is to compare the effect of structured and unstructured physical training on maximal aerobic capacity and HRV among adolescents. We designed a single blinded, parallel, randomized active-controlled trial (Registration No. CTRI/2013/08/003897) to compare the physiological effects of 6 months of globally recommended structured physical activity (SPA), with that of unstructured physical activity (USPA) in healthy school-going adolescents. We recruited 439 healthy student volunteers (boys: 250, girls: 189) in the age group of 12-17 years. Randomization across the groups was done using age and gender stratified randomization method, and the participants were divided into two groups: SPA (n=219, boys: 117, girls: 102) and USPA (n=220, boys: 119, girls: 101). Depending on their training status and gender the participants in both SPA and USPA groups were further subdivided into the following four sub-groups: SPA athlete boys (n=22) and girls (n=17), SPA nonathlete boys (n=95) and girls (n=85), USPA athlete boys (n=23) and girls (n=17), and USPA nonathlete boys (n=96) and girls (n=84). We recorded HRV, body fat%, and VO2 max using Rockport Walk Fitness test before and after the intervention. Maximum aerobic capacity and heart rate variability increased significantly while heart rate, systolic blood pressure, diastolic blood pressure, and body fat percentage decreased significantly after both SPA and USPA intervention. However, the improvement was more in SPA as compared to USPA. SPA is more beneficial for improving cardiorespiratory fitness, HRV, and reducing body fat percentage in terms of

  10. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis.

    Science.gov (United States)

    Baumgart, Julia Kathrin; Brurok, Berit; Sandbakk, Øyvind

    2018-01-01

    Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Systematic literature review and meta-analysis. PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in sports with few

  11. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis.

    Directory of Open Access Journals (Sweden)

    Julia Kathrin Baumgart

    Full Text Available Peak oxygen uptake (VO2peak in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested.To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak.Systematic literature review and meta-analysis.PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean.Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included.Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak.Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in

  12. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis

    Science.gov (United States)

    Brurok, Berit; Sandbakk, Øyvind

    2018-01-01

    Background Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. Objectives To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Design Systematic literature review and meta-analysis. Data sources PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Eligibility criteria Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data synthesis Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Results Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1

  13. The Effects of Food Labelling on Postexercise Energy Intake in Sedentary Women

    OpenAIRE

    Lafrenière, Jacynthe; McNeil, Jessica; Provencher, Véronique; Doucet, Éric

    2017-01-01

    Food labelling has been previously reported to influence energy intake (EI). Whether food labels influence postexercise EI remains to be determined. We assessed how food labelling and exercise (Ex) interact to influence food perception and postexercise EI. In this randomized crossover design, 14 inactive women participated in 4 experimental conditions: Ex (300?kcal at 70% of VO2peak) and lunch labelled as low in fat (LF), Ex and lunch labelled as high in fat (HF), Rest and LF, and Rest and HF...

  14. 'Multi-associations': predisposed to misinterpretation of peripheral tissue oxygenation and circulation in neonates

    International Nuclear Information System (INIS)

    Pichler, Gerhard; Pocivalnik, Mirjam; Pichler-Stachl, Elisabeth; Morris, Nicholas; Zotter, Heinz; Müller, Wilhelm; Urlesberger, Berndt; Riedl, Regina

    2011-01-01

    Interpretation of peripheral circulation in ill neonates is crucial but difficult. The aim was to analyse parameters potentially influencing peripheral oxygenation and circulation. In a prospective observational cohort study in 116 cardio-circulatory stable neonates, peripheral muscle near-infrared spectroscopy (NIRS) with venous occlusion was performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO 2 ), fractional oxygen extraction (FOE), fractional tissue oxygen extraction (FTOE), haemoglobin flow (Hbflow), oxygen delivery (DO 2 ), oxygen consumption (VO 2 ), and vascular resistance (VR) were assessed. Correlation coefficients between NIRS parameters and demographic parameters (gestational age, birth weight, age, actual weight, diameter of calf, subcutaneous adipose tissue), monitoring parameters (heart rate, arterial oxygen saturation (SaO 2 ), mean blood pressure (MAP), core/peripheral temperature, central/peripheral capillary refill time) and laboratory parameters (haemoglobin concentration (Hb-blood), pCO 2 ) were calculated. All demographic parameters except for Hbflow and DO 2 correlated with NIRS parameters. Heart rate correlated with TOI, SvO 2 , VO 2 and VR. SaO 2 correlated with FOE/FTOE. MAP correlated with Hbflow, DO 2 , VO 2 and VR. Core temperature correlated with FTOE. Peripheral temperature correlated with all NIRS parameters except VO 2 . Hb-blood correlated with FOE and VR. pCO 2 levels correlated with TOI and SvO 2 . The presence of multiple interdependent factors associated with peripheral oxygenation and circulation highlights the difficulty in interpreting NIRS data. Nevertheless, these findings have to be taken into account when analysing peripheral oxygenation and circulation data

  15. 'Multi-associations': predisposed to misinterpretation of peripheral tissue oxygenation and circulation in neonates.

    Science.gov (United States)

    Pichler, Gerhard; Pocivalnik, Mirjam; Riedl, Regina; Pichler-Stachl, Elisabeth; Morris, Nicholas; Zotter, Heinz; Müller, Wilhelm; Urlesberger, Berndt

    2011-08-01

    Interpretation of peripheral circulation in ill neonates is crucial but difficult. The aim was to analyse parameters potentially influencing peripheral oxygenation and circulation. In a prospective observational cohort study in 116 cardio-circulatory stable neonates, peripheral muscle near-infrared spectroscopy (NIRS) with venous occlusion was performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO(2)), fractional oxygen extraction (FOE), fractional tissue oxygen extraction (FTOE), haemoglobin flow (Hbflow), oxygen delivery (DO(2)), oxygen consumption (VO(2)), and vascular resistance (VR) were assessed. Correlation coefficients between NIRS parameters and demographic parameters (gestational age, birth weight, age, actual weight, diameter of calf, subcutaneous adipose tissue), monitoring parameters (heart rate, arterial oxygen saturation (SaO(2)), mean blood pressure (MAP), core/peripheral temperature, central/peripheral capillary refill time) and laboratory parameters (haemoglobin concentration (Hb-blood), pCO(2)) were calculated. All demographic parameters except for Hbflow and DO(2) correlated with NIRS parameters. Heart rate correlated with TOI, SvO(2), VO(2) and VR. SaO(2) correlated with FOE/FTOE. MAP correlated with Hbflow, DO(2), VO(2) and VR. Core temperature correlated with FTOE. Peripheral temperature correlated with all NIRS parameters except VO(2). Hb-blood correlated with FOE and VR. pCO(2) levels correlated with TOI and SvO(2). The presence of multiple interdependent factors associated with peripheral oxygenation and circulation highlights the difficulty in interpreting NIRS data. Nevertheless, these findings have to be taken into account when analysing peripheral oxygenation and circulation data.

  16. The relationship between heart rate and rate of oxygen consumption in Galapagos marine iguanas (Amblyrhynchus cristatus) at two different temperatures.

    Science.gov (United States)

    Butler, Patrick J; Frappell, Peter B; Wang, Tobias; Wikelski, Martin

    2002-07-01

    To enable the use of heart rate (fH) for estimating field metabolic rate (FMR) in free-ranging Galapagos marine iguanas Amblyrhynchus cristatus, we determined the relationships between fH and mass-specific rate of oxygen consumption (sVO2) in seven iguanas before and during exercise on a treadmill and during the post-exercise period. The experiments were conducted at 27 and 35 degrees C, which are the temperatures that represent the lowest and highest average body temperatures of these animals in the field during summer. There were linear and significant relationships between fH and sVO2 at both temperatures (r(2)=0.86 and 0.91 at 27 degrees C and 36 degrees C, respectively). The slopes of the two regression lines did not differ, but there were significant differences in their intercepts. Thus, while heart rate can be used to predict FMR, the effects of temperature on the intercept of the regression must be taken into account when converting fH to sVO2. On the basis of our data, this can be achieved by applying the following formula: sVO2=0.0113fH-0.2983Q(10)((T(b)-27)/10). The increase in sVO2 with elevated body temperature results from an increase in fH, with no significant change in mass-specific oxygen pulse (sO(2) pulse; cardiac stroke volume times the difference in oxygen content between arterial and mixed venous blood). However, during exercise at both temperatures, increases in fH are insufficient to provide all of the additional O(2) required and there are also significant increases in the sO(2) pulses. This creates the situation whereby the same fH at the two temperatures can represent different values of sVO2.

  17. The effect of acute L-Carnitine supplementation on the blood lactate, glucose, VO2max and power in trained men: a brief report

    Directory of Open Access Journals (Sweden)

    Arazi H

    2013-04-01

    Full Text Available Background: Probably L-Carnitine can induce increasing of Pyruvate dehydrogenase activity, decreasing of lactic acid production and performance improvements due to the reinforcement of long chain fatty acid oxidation and stabilize of Coenzyme A (CoASH to free Coenzyme A (COA. Based on this, the aim of this study was to investigate the effect of acute L-Carnitine supplementation on blood lactate, glucose, VO2max and anaerobic power in trained men.Methods: Sixteen trained men (aged 19-23 volunteers from University of Guilan, facul-ty of Physical Education and Sport Sciences participated as subjects in this investiga-tion. Subjects divided to aerobic (A and anaerobic (An group randomly. In a double blind design, subjects participated in two separated tests by one week. Subjects ingested 3 grams of L-Carnitine supplementation or placebo (maltodextrin 90 minute before aerobic and anaerobic exercise. For aerobic activity used shuttle run 20 meter and for anaerobic activity used RAST test. Blood samples were collected 5 minute prior at rest and 4 minute post tests. Participants were asked in the morning to obtain fasting blood samples and perform tests. A t-test was used to detect differences between supplementa-tion and placebo groups in each exercise.Results: L-Carnitine group ((A 141.25±20.62 and (An 145.38±55.47 significantly had lower lactate concentration than placebo ((A 151.00±20.85 and (An 152.50±28.59 after tests (P≤0.05. L-Carnitine group ((A 136.00±19.74 and (An 115.50±13.64 had significa-ntly higher blood glucose compared to placebo ((A 121.62±15.65 and (An 110.12±12.63 too (P≤0.05. Also, VO2max, mean and maximum anaerobic power in L-Carnitine group were significantly more than ones in placebo (P<0.05.Conclusion: These findings indicate that acute oral supplementation of L-Carnitine can induce fatigue decreasing and improvement of aerobic and anaerobic performance.

  18. Relationship between protein intake and dynapenia in postmenopausal women.

    Science.gov (United States)

    Filion, M E; Barbat-Artigas, S; Dupontgand, S; Fex, A; Karelis, A D; Aubertin-Leheudre, M

    2012-07-01

    The purpose of this study was to investigate the relationship between protein intake and dynapenia. A cross-sectional/observational study. Department of Kinanthropology at the University of Quebec at Montreal. Seventy-two non-frail postmenopausal women aged between 50 to 75 years were recruited. Body weight (BW), lean body mass (LBM; %) and skeletal muscle mass (bio-electrical impedancemetry analysis), maximum voluntary handgrip strength (using hand dynamometer), aerobic capacity (VO2peak) and dietary intake were measured. Women were divided according to dynapenia criteria. The strongest correlation between muscle strength and protein intake was observed when we express the amount of protein in g/d/BW. No differences for age, BMI, status of menopause, fat mass and VO2peak were observed between non-dynapenic, type I dynapenic and type II dynapenic women, independently of the criteria used. We observed significant differences in protein intake (g/d/BW) between non-dynapenic and type II dynapenic (p<0.01) as well as between type I dynapenic and type II dynapenic (p<0.01) when dynapenia was expressed in kg/BW and in kg/LBM, respectively. It should be noted that no differences in LBM between the three groups were observed when dynapenia was expressed in kg/BW and kg/LBM. Protein intake for all groups respected the RDA of 0.8 to 1.2 g/d/BW (non-dynapenic: 1.44/1.38; type I dynapenic: 1.30/1.33; type II dynapenic: 1.05/1.08 g/d/BW). Protein intake seems to play a role in the development of dynapenia particularly at the level of type II dynapenia. Therefore, an increase in the recommended daily allowance for protein intake may be warranted.

  19. Intake port

    Science.gov (United States)

    Mendler, Edward Charles

    2005-02-01

    The volumetric efficiency and power of internal combustion engines is improved with an intake port having an intake nozzle, a venturi, and a surge chamber. The venturi is located almost halfway upstream the intake port between the intake valves and the intake plenum enabling the venturi throat diameter to be exceptionally small for providing an exceptionally high ram velocity and an exceptionally long and in turn high efficiency diffuser flowing into the surge chamber. The intake port includes an exceptionally large surge chamber volume for blow down of the intake air into the working cylinder of the engine.

  20. THE COMBINATION OF α-LIPOIC ACID INTAKE WITH ECCENTRIC EXERCISE MODULATES ERYTHROPOIETIN RELEASE.

    Science.gov (United States)

    Morawin, B; Turowski, D; Naczk, M; Siatkowski, I; Zembron-Lacny, A

    2014-08-01

    The generation of reactive nitrogen/oxygen species (RN/OS) represents an important mechanism in erythropoietin (EPO) expression and skeletal muscle adaptation to physical and metabolic stress. RN/OS generation can be modulated by intense exercise and nutrition supplements such as α-lipoic acid, which demonstrates both anti- and pro-oxidative action. The study was designed to show the changes in the haematological response through the combination of α-lipoic acid intake with running eccentric exercise. Sixteen healthy young males participated in the randomised and placebo-controlled study. The exercise trial involved a 90-min run followed by a 15-min eccentric phase at 65% VO2max (-10% gradient). It significantly increased serum concentrations of nitric oxide (NO), hydrogen peroxide (H2O2) and pro-oxidative products such as 8-isoprostanes (8-iso), lipid peroxides (LPO) and protein carbonyls (PC). α-Lipoic acid intake (Thiogamma: 1200 mg daily for 10 days prior to exercise) resulted in a 2-fold elevation of serum H2O2 concentration before exercise, but it prevented the generation of NO, 8-iso, LPO and PC at 20 min, 24 h, and 48 h after exercise. α-Lipoic acid also elevated serum EPO level, which highly correlated with NO/H2O2 ratio (r = 0.718, P exercise (placebo 732 ± 207 IU · L(-1), α-lipoic acid 481 ± 103 IU · L(-1)), and correlated with EPO (r = 0.478, P release and reduces muscle damage after running eccentric exercise.

  1. Estimation of peak oxygen uptake from maximal power output among 9-10 year-old children in Lhasa, Tibet

    DEFF Research Database (Denmark)

    Bianba, B; Berntsen, S; Andersen, Lars Bo

    2010-01-01

    with the equations from the present study. None of the three could accurately predict the direct measured V.O2peak, and predictions differed in an unsystematic manner, including over- or underestimation and no differentiation between genders. CONCLUSION: Peak oxygen uptake could be estimated from Wmax and sex...

  2. Comparison of the Danish step test and the watt-max test for estimation of maximal oxygen uptake

    DEFF Research Database (Denmark)

    Aadahl, Mette; Zacho, Morten; Linneberg, Allan René

    2013-01-01

    . Altogether, 795 eligible participants (response rate 35.8%) performed the watt max and the Danish step test. Correlation and agreement between the two VO(2max) test results was explored by Pearson's rho, Bland-Altman plots, Kappa(w), and gamma coefficients.Results: The correlation between VO(2max) (ml......Introduction: There is a need for simple and feasible methods for estimation of cardiorespiratory fitness (CRF) in large study populations, as existing methods for valid estimation of maximal oxygen consumption are generally time consuming and relatively expensive to administer. The Danish step...

  3. Effects of high dose coffee intake on aerobic power in dragon female athletes

    Directory of Open Access Journals (Sweden)

    Shabani Ramin

    2016-08-01

    Full Text Available Background : There are few studies that consider the effect of high doses of caffeine on aerobic power (VO2max. Also, to date, no study examined the effect of coffee intake on dragon boat paddler specifically on women. The purpose of this study was to investigate the effect of espresso coffee on improvement of aerobic power of dragon boat paddler. Material : Twenty women athletes of Guilan dragon bout team members of Malavan club of port city of Anzali (mean ±SD age, 23.60± 3.49 years; BMI,23.77±1.88kg/m2; body fat, 30.32±4.65% were recruited to this study, after they completed a primary test without consuming any coffee, they consumed 6mg/kg of coffee (espresso or decaffeinated and following that they completed two experimental trials. A randomized, double-blind, repeated-measures, design was employed whereby paddlers complete a 2000m paddling dragon boat ergo-meter. Results : Coffee could improve VO2max (Without coffee =74.40± QUOTE 4.99, Espresso coffee =90.10± QUOTE 6.19, Decaffeinated coffee =91.00± QUOTE 5.67, P≤ QUOTE 0.05. VO2max amount after exercise were significantly higher for both espresso coffee and decaffeinated coffee, when compared with without coffee condition. No significant differences were observed between espresso coffee and decaffeinated coffee (P≤ QUOTE 0.05. Conclusion : The present study shows that both high doses of caffeine (espresso coffee and decaffeinated coffee can enhance VO2max during aerobic exercise including 2000m dragon boat paddling. It seems that some compounds except caffeine in decaffeinated coffee can act improve VO2max. Further studies needed for considering the effect of high doses of coffee on endurance exercises. Also in other age ranges of women athletes and other sport athletes.

  4. Fine hierarchy of the V-O bonds by advanced solid state NMR: novel Pb4(VO2)(PO4)3 structure as a textbook case.

    Science.gov (United States)

    Tricot, Grégory; Mentré, Olivier; Cristol, Sylvain; Delevoye, Laurent

    2012-12-17

    We report here a complete structural characterization of a new lead Pb(4)(VO(2))(PO(4))(3) vanadophosphate compound by single crystal X-ray diffraction and (51)V and (31)P solid-state NMR spectroscopy. Although structural data are commonly used for the estimation of bond lengths and further delimitation of the true coordination number (e.g., octahedral: 6 versus 5 + 1 versus 4 + 2), we show here for the first time by solid-state NMR a more accurate appreciation of the V-O bonding scheme in this complex oxide which appears well adapted to the full series of vanado-phosphate materials. The direct characterization of V-O-P bridges through the J-mediated correlation (51)V{(31)P} heteronuclear multiple quantum coherence (J-HMQC) technique allows a contrasted hierarchy of the V-O electronic delocalization and indirectly supports the presence or not of the V-O bond. In the reported lead vanado-phosphate structure, the two vanadium polyhedra that have been assigned to octahedra from a bond length point of view have been finally reclassified as tetra- and penta-coordinated units on the basis of the solid-state NMR results. More generally, we believe that the improved characterization of interatomic bonds in various vanado-phosphate structures by solid-state NMR will contribute to a better understanding of the structure/property relationships in this important class of materials.

  5. Health-Related Physical Fitness in Healthy Untrained Men: Effects on VO2max, Jump Performance and Flexibility of Soccer and Moderate-Intensity Continuous Running

    Science.gov (United States)

    Milanović, Zoran; Pantelić, Saša; Sporiš, Goran; Mohr, Magni; Krustrup, Peter

    2015-01-01

    The purpose of this study was to determine the effects of recreational soccer (SOC) compared to moderate-intensity continuous running (RUN) on all health-related physical fitness components in healthy untrained men. Sixty-nine participants were recruited and randomly assigned to one of three groups, of which sixty-four completed the study: a soccer training group (SOC; n = 20, 34±4 (means±SD) years, 78.1±8.3 kg, 179±4 cm); a running group (RUN; n = 21, 32±4 years, 78.0±5.5 kg, 179±7 cm); or a passive control group (CON; n = 23, 30±3 years, 76.6±12.0 kg, 178±8 cm). The training intervention lasted 12 weeks and consisted of three 60-min sessions per week. All participants were tested for each of the following physical fitness components: maximal aerobic power, minute ventilation, maximal heart rate, squat jump (SJ), countermovement jump with arm swing (CMJ), sit-and-reach flexibility, and body composition. Over the 12 weeks, VO2max relative to body weight increased more (psoccer training and moderate-intensity running, partly due to large decreases in body mass. Additionally soccer training induced pronounced positive effects on jump performance and flexibility, making soccer an effective broad-spectrum fitness training intervention. PMID:26305880

  6. Cardiorespiratory Responses and Prediction of Peak Oxygen Uptake during the Shuttle Walking Test in Healthy Sedentary Adult Men

    Science.gov (United States)

    Neves, Camila D. C.; Lacerda, Ana Cristina Rodrigues; Lage, Vanessa K. S.; Lima, Liliana P.; Fonseca, Sueli F.; de Avelar, Núbia C. P.; Teixeira, Mauro M.; Mendonça, Vanessa A.

    2015-01-01

    Background The application of the Shuttle Walking Test (SWT) to assess cardiorespiratory fitness and the intensity of this test in healthy participants has rarely been studied. This study aimed to assess and correlate the cardiorespiratory responses of the SWT with the cardiopulmonary exercise testing (CEPT) and to develop a regression equation for the prediction of peak oxygen uptake (VO2 peak) in healthy sedentary adult men. Methods In the first stage of this study, 12 participants underwent the SWT and the CEPT on a treadmill. In the second stage, 53 participants underwent the SWT twice. In both phases, the VO2 peak, respiratory exchange ratio (R), and heart rate (HR) were evaluated. Results Similar results in VO2 peak (P>0.05), R peak (P>0.05) and predicted maximum HR (P>0.05) were obtained between the SWT and CEPT. Both tests showed strong and significant correlations of VO2 peak (r = 0.704, P = 0.01) and R peak (r = 0.737, P0.05) was found. Conclusions The SWT produced maximal cardiorespiratory responses comparable to the CEPT, and the developed equation showed viability for the prediction of VO2 peak in healthy sedentary men. PMID:25659094

  7. Oxygen cost and physiological responses of recreational badminton match play.

    Science.gov (United States)

    Deka, Pallav; Berg, Kris; Harder, Jeanette; Batelaan, Herman; McGRATH, Melanie

    2017-06-01

    Badminton, as an Olympic sport, is popular worldwide. However, the benefits of recreational badminton match play are not well known. The purpose of the study was to determine the oxygen cost of recreational badminton match play. Heart rate (HR), blood lactate (BL), rating of perceived exertion (RPE), step count and energy expenditure were also assessed. Fourteen male recreational badminton players aged 35.9±6.62 years participated in test sessions to assess oxygen uptake (VO2) and the related physiological responses of match play. During the match play sessions, participants played singles badminton matches for 30 min while wearing a portable metabolic system. VO2 and HR were continuously recorded while blood lactate and RPE were determined following warm-up, at 15 minutes and 30 minutes of match play. Step count was recorded at 15 minutes and 30 minutes of play. VO2 over 30 minutes was 34.4±5.8 mL/kg/min which was 76.1% of maximal oxygen uptake. Across three 10-minute periods of play, VO2 was not significantly different while HR was higher in the third 10-minute period than the first and second 10-minute periods (P=0.001). Mean HR over 30 minutes was 167.9±9.4 bpm. BL was significantly higher at 15 and 30 minutes than following warm-up while RPE of 17.57±1.91 after 30 minutes was significantly higher (P=0.009) than RPE of 15.79±1.63 at 15 minutes. Step count did not vary between the two 15-minute periods of play with a total of 2404±360 steps while energy expenditure over 30 minutes of play was 391.7±66 kcal. Recreational badminton match play can be categorized as vigorous intensity suggesting that it can be a viable means of achieving recommended physical activity and improving aerobic fitness.

  8. OXYGEN UPTAKE KINETICS DURING INCREMENTAL- AND DECREMENTAL-RAMP CYCLE ERGOMETRY

    Directory of Open Access Journals (Sweden)

    Fadıl Özyener

    2011-09-01

    Full Text Available The pulmonary oxygen uptake (VO2 response to incremental-ramp cycle ergometry typically demonstrates lagged-linear first-order kinetics with a slope of ~10-11 ml·min-1·W-1, both above and below the lactate threshold (ӨL, i.e. there is no discernible VO2 slow component (or "excess" VO2 above ӨL. We were interested in determining whether a reverse ramp profile would yield the same response dynamics. Ten healthy males performed a maximum incremental -ramp (15-30 W·min-1, depending on fitness. On another day, the work rate (WR was increased abruptly to the incremental maximum and then decremented at the same rate of 15-30 W.min-1 (step-decremental ramp. Five subjects also performed a sub-maximal ramp-decremental test from 90% of ӨL. VO2 was determined breath-by-breath from continuous monitoring of respired volumes (turbine and gas concentrations (mass spectrometer. The incremental-ramp VO2-WR slope was 10.3 ± 0.7 ml·min-1·W-1, whereas that of the descending limb of the decremental ramp was 14.2 ± 1.1 ml·min-1·W-1 (p < 0.005. The sub-maximal decremental-ramp slope, however, was only 9. 8 ± 0.9 ml·min-1·W-1: not significantly different from that of the incremental-ramp. This suggests that the VO2 response in the supra-ӨL domain of incremental-ramp exercise manifest not actual, but pseudo, first-order kinetics

  9. Lactate, endothelin, and central venous oxygen saturation as predictors of mortality in patients with Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Poonam Malhotra Kapoor

    2016-01-01

    Full Text Available Background: Lactate and central venous oxygen saturation (ScVO2 are well known biomarkers for adequacy of tissue oxygenation. Endothelin, an inflammatory marker has been associated with patient′s nutritional status and degree of cyanosis. The aim of this study was to explore the hypothesis that lactate, ScVO2 and endothelin before induction may be predictive of mortality in pediatric cardiac surgery. Methods: We conducted a prospective observational study of 150 pediatric (6 months to 12 years patients who were posted for intracardiac repair for tetralogy of fallot and measured lactate, ScVO2 and endothelin before induction (T1, 20 minutes after protamine administration (T2 and 24 hours after admission to ICU (T3. Results: Preinduction lactate and endothelin levels were found to predict mortality in patients of tetralogy of fallot with an odds ratio of 6.020 (95% CI 2.111-17.168 and 1.292(95% CI 1.091-1.531 respectively. In the ROC curve analysis for lactate at T1, the AUC was 0.713 (95% CI 0.526-0.899 P = 0.019. At the cutoff value of 1.750mmol/lt, the sensitivity and specificity for the prediction of mortality was 63.6% and 65.5%, respectively. For endothelin at T1, the AUC was 0.699 (95% CI 0.516-0.883, P = 0.028 and the cutoff value was ≤2.50 (sensitivity, 63.6%; specificity, 58.3 %. ScVO2 (odds ratio 0.85 at all three time intervals, suggested that improving ScVO2 can lead to 15% reduction in mortality. Conclusions: Lactate, ScVO2 and endothelin all showed association with mortality with lactate having the maximum prediction. Lactate was found to be an independent, reliable and cost-effective measure of prediction of mortality in patients with tetralogy of fallot.

  10. Estimation of maximal oxygen uptake via submaximal exercise testing in sports, clinical, and home settings.

    Science.gov (United States)

    Sartor, Francesco; Vernillo, Gianluca; de Morree, Helma M; Bonomi, Alberto G; La Torre, Antonio; Kubis, Hans-Peter; Veicsteinas, Arsenio

    2013-09-01

    Assessment of the functional capacity of the cardiovascular system is essential in sports medicine. For athletes, the maximal oxygen uptake [Formula: see text] provides valuable information about their aerobic power. In the clinical setting, the (VO(2max)) provides important diagnostic and prognostic information in several clinical populations, such as patients with coronary artery disease or heart failure. Likewise, VO(2max) assessment can be very important to evaluate fitness in asymptomatic adults. Although direct determination of [VO(2max) is the most accurate method, it requires a maximal level of exertion, which brings a higher risk of adverse events in individuals with an intermediate to high risk of cardiovascular problems. Estimation of VO(2max) during submaximal exercise testing can offer a precious alternative. Over the past decades, many protocols have been developed for this purpose. The present review gives an overview of these submaximal protocols and aims to facilitate appropriate test selection in sports, clinical, and home settings. Several factors must be considered when selecting a protocol: (i) The population being tested and its specific needs in terms of safety, supervision, and accuracy and repeatability of the VO(2max) estimation. (ii) The parameters upon which the prediction is based (e.g. heart rate, power output, rating of perceived exertion [RPE]), as well as the need for additional clinically relevant parameters (e.g. blood pressure, ECG). (iii) The appropriate test modality that should meet the above-mentioned requirements should also be in line with the functional mobility of the target population, and depends on the available equipment. In the sports setting, high repeatability is crucial to track training-induced seasonal changes. In the clinical setting, special attention must be paid to the test modality, because multiple physiological parameters often need to be measured during test execution. When estimating VO(2max), one has

  11. Cadetes of the Academia do Polícia Militar do Estado do Rio de Janeiro Correlación entre VO2 max, gordura relativa y perfil lipídico, en cadetes de la Academia de Policía Militar del Estado de Río de Janeiro

    Directory of Open Access Journals (Sweden)

    E. H. M. Dantas

    2010-09-01

    Full Text Available The objective of the present study was to verify the correlation level among the max, the relative fat and the profile lipídico of 51 Cadets (Age = 23.63 3.58 years; Weight = 74.13 ± 10.46 kg; Height = 1.76 ± 0.06 m; IMC = 23.99 2.76 kg/m2, of the masculine gender, of the Academy of the Military police of the State of Rio de Janeiro, of the year of 2007. The subjects were active and participants of the military physical training (TFM accomplished five times a week, with duration of 60 minutes for session. They were appraised: the max for ergoespirometria (I record of progressive effort, with constant inclination of 3% and initial speed of 4,0km/h, the relative fat (% G - I record of three cutaneous folds and the profile lipídico, through the method Enzymatic Calorimétrico in the variables: total cholesterol (CT, triglicérides (TG, lipoproteína of density high-cholesterol (HDL-C and lipoproteína of density low-cholesterol (LDL-C. The test of correlation of Spearman presented correlation significant between max and TG (r = -0,289; p = 0,04,  max and HDL-C (r = 0,277; p = 0,049,% G and TG (r = 0,296; p = 0,035,% G and HDL-C (r = 0,338; p = 0,015. Like this, these discoveries point a discreet relationship between the profile lipídico and the maximum consumption of oxygen corroborating the need to consider other factors as the feeding and the intensity of the exercises in the investigation of this relationship.

    Key Words: training,  VO2 max, relative fat, lipidic profile.

     

    El objetivo del presente estudio es establecer el nivel de correlación entre el  VO2 max, la grasa relativa y el perfil lipídico de 51 cadetes varones (Edad = 23.63 ± 3.58 años; Peso = 74.13 ± 10.46 Kg.; Talla = 1.76  ± 0.06 m; IMC = 23.99 ± 2.76 Kg. /m2 de la Academia de la Policía Militar del Estado de Río de Janeiro, del año de 2007. Los sujetos son f

  12. Ammonia producing engine utilizing oxygen separation

    Science.gov (United States)

    Easley, Jr., William Lanier; Coleman, Gerald Nelson [Petersborough, GB; Robel, Wade James [Peoria, IL

    2008-12-16

    A power system is provided having a power source, a first power source section with a first intake passage and a first exhaust passage, a second power source section with a second intake passage and a second exhaust passage, and an oxygen separator. The second intake passage may be fluidly isolated from the first intake passage.

  13. A comparison of methods of predicting maximum oxygen uptake.

    OpenAIRE

    Grant, S; Corbett, K; Amjad, A M; Wilson, J; Aitchison, T

    1995-01-01

    The aim of this study was to compare the results from a Cooper walk run test, a multistage shuttle run test, and a submaximal cycle test with the direct measurement of maximum oxygen uptake on a treadmill. Three predictive tests of maximum oxygen uptake--linear extrapolation of heart rate of VO2 collected from a submaximal cycle ergometer test (predicted L/E), the Cooper 12 min walk, run test, and a multi-stage progressive shuttle run test (MST)--were performed by 22 young healthy males (mean...

  14. Maximum oxygen uptake and objectively measured physical activity in Danish children 6-7 years of age: the Copenhagen school child intervention study

    DEFF Research Database (Denmark)

    Eiberg, Stig; Hasselstrøm, Henriette; Grønfeldt, Vivian

    2005-01-01

    Objectives: To provide normative data on maximum oxygen uptake (V·O2MAX) and physical activity in children 6-7 years of age and analyse the association between these variables. Methods: VO2MAX was measured in 366 boys (mean (SD) 6.8 (0.4) years of age) and 332 girls (6.7 (0.4) years of age) from.......5 (6.0) v 44.8 (5.6) ml/kg/min (+8%); pgirls. The difference in VO2MAX between boys and girls decreased to +2% when expressed relative to lean body mass (LBM). Absolute VO2MAX was related to LBM, body mass, and stature (all pBoys were more physically active than girls (mean counts...... +9.4%, pboys and girls with the same VO2MAX were compared, boys were more active. The difference in physical activity between the sexes was higher when sustained activity of higher intensity was compared. Conclusions: VO2MAX is higher in boys than girls (+11%), even when...

  15. Do individuals with intellectual disability have a lower peak heart rate and maximal oxygen uptake?

    Science.gov (United States)

    Hilgenkamp, Thessa Irena Maria; Baynard, Tracy

    2017-12-12

    Individuals with intellectual disability (ID) have very low physical activity and low peak oxygen uptake (VO 2peak ), potentially explained by physiologically lower peak heart rates (HR peak ). The present authors performed a retrospective analysis of a large data set of individuals with intellectual disability (n = 100), with Down syndrome (DS) (n = 48) and without intellectual disability (n = 224) using multiple linear regression analyses, to determine if individuals with intellectual disability exhibit lower HR peak and VO 2peak than individuals without intellectual disability, controlling for age, sex and body mass index (BMI). Individuals with intellectual disability on average have significantly lower HR peak and VO 2peak than individuals without intellectual disability, even when controlling VO 2peak for the lower HR peak . This study suggests potential physiological differences in individuals with intellectual disability and warrants further investigation to determine their relevance to physical activity promotion and exercise testing in individuals with intellectual disability. © 2017 John Wiley & Sons Ltd.

  16. Thermodynamic studies at the low-dimensional spin systems HP-(VO)2P2O7, SrCu2(BO3)2, and azurite

    International Nuclear Information System (INIS)

    Bruehl, Andreas

    2007-01-01

    The present thesis deals with the low-temperature properties of three low-dimensional spin systems. The main experimental topic lies on measurements on the thermal expansion and on the specific heat, which were performed with a high-resolution capacitative dilatometer respectively an AC calorimeter facility. Because the so-called magnetic Grueneisen parameters, which describe the strength of the coupling of the magnetic partial system to the lattice, are throughout very large, especially the thermal-expansion measurements yield valuable information on the understanding of the treated systems. The central result of this thesis represent measurements on the high-pressure phase of (VO) 2 P 2 O 7 , briefly PP-VOPO. This system consists of alternating spin chains, whereby both exchange constants have similar values, i. e. only a weak alternation is present. In the thermal expansion an anomaly especially pronounced in chain direction at about 13 K. From the Grueneisen parameters determined by application of this model it can be concluded that the pronounced low-temperature anomaly in HP-VOPO is partly caused by the strong deformation dependence of the smaller of the two exchange constants, but partly also on the neighbourhood to a quantum critical point. The two-dimensional dimer system SrCu 2 (BO 3 ) 2 has gotten fame by the localization of the triplet excitations and the magnetization plateaus at certain fractions of the saturation magnetization conditioned by this. In the thermal expansion a distinct anomaly at the same temperature (T=8 K) is observed, as it also occurs in the specific heat. Finally measurements at the natural mineral azurite are presented, in which the spin are arranged in so-called diamond chains. In the magnetic susceptibility, the specific heat, and the thermal expansion a remarkable double structure occurs. Also the Λ-shaped antiferromagnetic order transition was studied and the phase diagram, consisting of paramagnetic, antiferromagnetic, and

  17. Effect of music-movement synchrony on exercise oxygen consumption.

    Science.gov (United States)

    Bacon, C J; Myers, T R; Karageorghis, C I

    2012-08-01

    Past research indicates that endurance is improved when exercise movements are synchronised with a musical beat, however it is unclear whether such benefits are associated with reduced metabolic cost. We compared oxygen consumption (.VO2) and related physiological effects of exercise conducted synchronously and asynchronously with music. Three music tracks, each recorded at three different tempi (123, 130, and 137 beats.min-1), accompanied cycle ergometry at 65 pedal revolutions.min-1. Thus three randomly-assigned experimental conditions were administered: slow tempo asynchronous, synchronous, and fast tempo asynchronous. Exercise response of .VO2, HR, and ratings of perceived exertion (RPE), to each condition was monitored in 10 untrained male participants aged 21.7±0.8 years (mean±SD) who cycled for 12 min at 70% maximal heart rate (HR). Mean .VO2 differed among conditions (P=0.008), being lower in the synchronous (1.80±0.22 L.min-1) compared to the slow tempo asynchronous condition (1.94±0.21 L.min-1; Pmusic than when musical tempo is slightly slower than the rate of cyclical movement.

  18. Oxygen consumption of elite distance runners on an anti-gravity treadmill®.

    Science.gov (United States)

    McNeill, David K P; Kline, John R; de Heer, Hendrick D; Coast, J Richard

    2015-06-01

    Lower body positive pressure (LBPP), or 'anti-gravity' treadmills® have become increasingly popular among elite distance runners. However, to date, few studies have assessed the effect of body weight support (BWS) on the metabolic cost of running among elite runners. This study evaluated how BWS influenced the relationship between velocity and metabolic cost among 6 elite male distance runners. Participants ran three- 16 minute tests consisting of 4 stages of 4 minutes at 8, 7, 6 and 5 min·mile(-1) pace (3.35, 3.84, 4.47 and 5.36 m·s(-1)), while maintaining an aerobic effort (Respiratory Exchange Ratio ≤1.00). One test was run on a regular treadmill, one on an anti-gravity treadmill with 40% BWS and one with 20% BWS being provided. Expired gas data were collected and regression equations used to determine and compare slopes. Significant decreases in oxygen uptake (V̇O2) were found with each increase in BWS (p rate, perceived exertion or directly measured oxygen uptake) should be used to guide training intensity when training on the LBPP treadmill. Key pointsWith increasing amounts of body weight-support (BWS), the slope of the relationship between velocity and oxygen consumption (ΔVO2/Δv) decreases significantly. This means the change in oxygen consumption (VO2) is significantly smaller over a given change in velocity at higher amounts of BWS.There is a non-linear decrease in VO2 with increasing BWS. As such, with each increment in the amount of BWS provided, the reduction in VO2 becomes increasingly smaller.This paper provides first of its kind data on the effects of BWS on the cost of running among highly trained, elite runners. The outcomes of this study are in line with previous findings among non-elite runners.

  19. Locomotor muscle fatigue does not alter oxygen uptake kinetics during high-intensity exercise

    Directory of Open Access Journals (Sweden)

    James Hopker

    2016-10-01

    Full Text Available The slow component (VO2sc that develops during high-intensity aerobic exercise is thought to be strongly associated with locomotor muscle fatigue. We sought to experimentally test this hypothesis by pre-fatiguing the locomotor muscles used during subsequent high-intensity cycling exercise. Over two separate visits, eight healthy male participants were asked to either perform a non-metabolically stressful 100 intermittent drop-jumps protocol (pre fatigue condition or rest for 33 minutes (control condition according to a random and counterbalanced order. Locomotor muscle fatigue was quantified with 6-second maximal sprints at a fixed pedaling cadence of 90 rev·min-1. Oxygen kinetics and other responses (heart rate, capillary blood lactate concentration and rating of perceived exertion, RPE were measured during two subsequent bouts of 6 min cycling exercise at 50% of the delta between the lactate threshold and VO2max determined during a preliminary incremental exercise test. All tests were performed on the same cycle ergometer. Despite significant locomotor muscle fatigue (P = 0.03, the VO2sc was not significantly different between the pre fatigue (464 ± 301 mL·min-1 and the control (556 ± 223 mL·min-1 condition (P = 0.50. Blood lactate response was not significantly different between conditions (P = 0.48 but RPE was significantly higher following the pre-fatiguing exercise protocol compared with the control condition (P < 0.01 suggesting higher muscle recruitment. These results demonstrate experimentally that locomotor muscle fatigue does not significantly alter the VO2 kinetic response to high intensity aerobic exercise, and challenge the hypothesis that the VO2sc is strongly associated with locomotor muscle fatigue.

  20. Training-induced acceleration of oxygen uptake kinetics in skeletal muscle: the underlying mechanisms.

    Science.gov (United States)

    Zoladz, J A; Korzeniewski, B; Grassi, B

    2006-11-01

    It is well known that the oxygen uptake kinetics during rest-to-work transition (V(O2) on-kinetics) in trained subjects is significantly faster than in untrained individuals. It was recently postulated that the main system variable that determines the transition time (t(1/2)) of the V(O2) on-kinetics in skeletal muscle, at a given moderate ATP usage/work intensity, and under the assumption that creatine kinase reaction works near thermodynamic equilibrium, is the absolute (in mM) decrease in [PCr] during rest-to-work transition. Therefore we postulate that the training-induced acceleration of the V(O2) on-kinetics is a marker of an improvement of absolute metabolic stability in skeletal muscles. The most frequently postulated factor responsible for enhancement of muscle metabolic stability is the training-induced increase in mitochondrial proteins. However, the mechanism proposed by Gollnick and Saltin (1982) can improve absolute metabolic stability only if training leads to a decrease in resting [ADP(free)]. This effect is not observed in many examples of training causing an acceleration of the V(O2) on-kinetics, especially in early stages of training. Additionally, this mechanism cannot account for the significant training-induced increase in the relative (expressed in % or as multiples of the resting values) metabolic stability at low work intensities, condition in which oxidative phosphorylation is not saturated with [ADP(free)]. Finally, it was reported that in the early stage of training, acceleration in the V(O2) on-kinetics and enhancement of muscle metabolic stability may precede adaptive responses in mitochondrial enzymes activities or mitochondria content. We postulate that the training-induced acceleration in the V(O2) on-kinetics and the improvement of the metabolite stability during moderate intensity exercise in the early stage of training is mostly caused by an intensification of the "parallel activation" of ATP consumption and ATP supply pathways

  1. EFECTO DE UN PLAN DE ENTRENAMIENTO FÍSICO EN EL CONSUMO MÁXIMO DE OXÍGENO (VO2MÁX Y EL PESO EN PACIENTES HIPERTENSOS ADULTOS MAYORES ADSCRITOS A LA IPS CAJASAN (BUCARAMANGA

    Directory of Open Access Journals (Sweden)

    Jorge Luis Pérez Sierra

    2014-11-01

    Full Text Available El ejercicio físico adquiere cada vez más importancia en el tratamiento de los pacientes con hipertensión arterial, sobrepeso y obesidad. Desde hace más de cinco décadas se sabe que el ejercicio físico tiene efectos favorables en el tratamiento de la hipertensión arterial y otros factores de riesgo, es coadyuvante en el tratamiento de las enfermedades cardiovasculares y favorece el consumo máximo de oxígeno (VO2máx. El objetivo de este trabajo fue determinar el efecto de un plan de entrenamiento físico sobre el VO2máx y el peso en adultos mayores hipertensos adscritos a la IPS Cajasan Bucaramanga. Es una investigación cuasiexperimental, se tomaron cuarenta pacientes entre 60 y 75 años, en dos grupos iguales, uno con entrenamiento aeróbico, fuerza y flexibilidad (intervención, el otro, caminata diaria, (control, con duración de doce semanas. Se tomó pretest y postest con prueba de esfuerzo, peso, índice de masa corporal, perímetro de cintura. Se compararon los resultados. En el grupo intervención, el VO2máx aumentó 27%, el peso disminuyó 2,2 %, el perímetro de cintura bajó el 2%. En el grupo control no hubo cambios significativos.

  2. Phthalate Intakes

    Data.gov (United States)

    U.S. Environmental Protection Agency — Compilation of literature-reported intake values of phthalates; specifically dibutyl phthalate (DBP), bis(2-ethylhexyl) phthalate, and diisononyl phthalate (DiNP)....

  3. Efeito do tempo de intervalo da amostra ventilatória na variabilidade do consumo máximo de oxigênio (VO2 máx em jogadores de futebol profissional

    Directory of Open Access Journals (Sweden)

    Paulo Roberto Santos Silva

    1999-04-01

    Full Text Available O propósito deste estudo foi verificar, em futebolistas profissionais, o impacto de sete intervalos de tempo sobre a variável fisiológica consumo máximo de oxigênio (VO2 máx. Dezoito jogadores de futebol com média de idade de 24 ± 4 anos (18-31, peso de 72,5 ± 5,9kg (62-83 e estatura de 176,5 ± 7,0cm (164-188 foram submetidos a teste ergométrico máximo em esteira rolante, utilizando-se protocolo escalonado contínuo. A resposta de freqüência cardíaca (FC foi registrada por meio de um eletrocardiógrafo computadorizado de 12 derivações simultâneas. A ventilação pulmonar (V E, o consumo de oxigênio (VO2, a produção de dióxido de carbono (VCO2 e a razão de troca respiratória (RER foram calculadas a partir de valores medidos por um sistema espirométrico computadorizado. Os resultados deste estudo demonstraram que houve variabilidade significante do VO2 máx (p < 0,05 somente quando se comparou a resposta instantânea respiração-a-respiração (breath-by-breath em relação aos outros intervalos de tempos analisados (10, 20, 30, 40, 50 e 60 segundos, respectivamente. Concluindo, durante o exercício de intensidade progressiva, observou-se que o aumento do VO2 foi proporcional à diminuição do intervalo de tempo da coleta ventilatória. O tempo de intervalo maior subestimou esse aumento. Assim, sugere-se que o avaliador utilize intervalos médios na faixa de tempo entre 10 e 60 segundos, pois não foi verificada diferença estatística significante entre esses intervalos.

  4. Effect of preexercise soup ingestion on water intake and fluid balance during exercise in the heat.

    Science.gov (United States)

    Johannsen, Neil M; Sullivan, Zebblin M; Warnke, Nicole R; Smiley-Oyen, Ann L; King, Douglas S; Sharp, Rick L

    2013-06-01

    To determine whether chicken noodle soup before exercise increases ad libitum water intake, fluid balance, and physical and cognitive performance compared with water. Nine trained men (age 25 ± 3 yr, VO2peak 54.2 ± 5.1 ml · kg-1 · min-1; M ± SD) performed cycle exercise in the heat (wet bulb globe temperature = 25.9 ± 0.4 °C) for 90 min at 50% VO2peak, 45 min after ingesting 355 ml of either commercially available bottled water (WATER) or chicken noodle soup (SOUP). The same bottled water was allowed ad libitum throughout both trials. Participants then completed a time trial to finish a given amount of work (10 min at 90% VO2peak; n = 8). Cognitive performance was evaluated by the Stroop color-word task before, every 30 min during, and immediately after the time trial. Ad libitum water intake throughout steady-state exercise was greater in SOUP than with WATER (1,435 ± 593 vs. 1,163 ± 427 g, respectively; p SOUP than in WATER (87.7% ± 7.6% vs. 74.9% ± 21.7%, respectively; p = .09), possibly due to a change in free water clearance (-0.32 ± 1.22 vs. 0.51 ± 1.06 ml/min, respectively; p = .07). Fluid balance tended to be improved with SOUP (-106 ± 603 vs. -478 ± 594 g, p = .05). Likewise, change in plasma volume tended to be reduced in SOUP compared with WATER (p = .06). Only mild dehydration was achieved (SOUP throughout the entire trial (treatment effect; p = .04). SOUP before exercise increased ad libitum water intake and may alter kidney function.

  5. [Oxygen peak consumption is a better predictor of cardiovascular risk than handgrip strength in older Chilean women].

    Science.gov (United States)

    Farías-Valenzuela, Claudio; Pérez-Luco, Cristian; Ramírez-Campillo, Rodrigo; Álvarez, Cristian; Castro-Sepúlveda, Mauricio

    Handgrip strength (HS) and peak oxygen consumption (Vo2peak) are powerful predictors of cardiovascular risk, although it is unknown which of the two variables is the better predictor. The objective of the following study was to relate HS and Vo2peak to cardiovascular risk markers in older Chilean women. Physically active adult women (n=51; age, 69±4.7years) participated in this study. The HS and Vo2peak were evaluated and related to the anthropometric variables of body mass, body mass index (BMI), waist circumference (WC), hip circumference (HC), waist ratio (WR), and waist height ratio (WHR), as well as with the cardiovascular variables systolic (SBP) and diastolic (DBP) and cardiac recovery in one minute (RHR1). A multilinear regression model was used for the analysis of the associated variables (Pcardiovascular risk markers associated (Pcardiovascular risk markers, Vo2peak offers greater associative power with these cardiovascular risk factors. Copyright © 2017 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Neuromuscular blockade of slow twitch muscle fibres elevates muscle oxygen uptake and energy turnover during submaximal exercise in humans.

    Science.gov (United States)

    Krustrup, Peter; Secher, Niels H; Relu, Mihai U; Hellsten, Ylva; Söderlund, Karin; Bangsbo, Jens

    2008-12-15

    We tested the hypothesis that a greater activation of fast-twitch (FT) fibres during dynamic exercise leads to a higher muscle oxygen uptake (VO2 ) and energy turnover as well as a slower muscle on-kinetics. Subjects performed one-legged knee-extensor exercise for 10 min at an intensity of 30 W without (CON) and with (CUR) arterial injections of the non-depolarizing neuromuscular blocking agent cisatracurium. In CUR, creatine phosphate (CP) was unaltered in slow twitch (ST) fibres and decreased (P fibres, whereas in CON, CP decreased (P fibres, respectively. From 127 s of exercise, muscle VO2 was higher (P muscle VO2 response was slower (P muscle homogenate CP was lowered (P muscle lactate production was similar in CUR and CON (37.8 +/- 4.1 versus 35.2 +/- 6.2 mmol). Estimated total muscle ATP turnover was 19% higher (P fibres are less efficient than ST fibres in vivo at a contraction frequency of 1 Hz, and that the muscle VO2 kinetics is slowed by FT fibre activation.

  7. Myosin heavy chain composition in the vastus lateralis muscle in relation to oxygen uptake and heart rate during cycling in humans.

    Science.gov (United States)

    Majerczak, J; Nieckarz, Z; Karasinski, J; Zoladz, J A

    2014-04-01

    In this study we examined the relationship between fast myosin heavy chain (MyHC2) content in the vastus lateralis and the rate of oxygen uptake (VO2) and heart rate (HR) increase during an incremental exercise in 38, young, healthy men. Prior to the exercise test, muscle biopsies were taken in order to evaluate the MyHC composition. It was found that during cycling performed below the lactate threshold (LT), a positive relationship between MyHC2 and the intercept of the oxygen uptake and power output (VO2-PO) relationship existed (r=0.49, P=0.002), despite no correlation between MyHC2 and the slope value of the VO2-PO relationship (r= -0.18, P=0.29). During cycling performed above the LT, MyHC2 correlated positively with the magnitude of the nonlinearity in the VO2-PO relationship; i.e. with the accumulated VO2'excess' (r=0.44, P=0.006) and peak VO2'excess' (r=0.44, P=0.006), as well as with the slope of the HR-PO relationship (r=0.49, P=0.002). We have concluded that a greater MyHC2 content in the vastus lateralis is accompanied by a higher oxygen cost of cycling during exercise performed below the LT. This seems to be related to the higher energy cost of the non-cross-bridge activities in the muscles possessing a greater proportion of MyHC2 content. In the case of heavy-intensity exercise, a higher MyHC2 content in the vastus lateralis is accompanied by greater non-linearity in the VO2-PO relationship, as well as a steeper increase in HR in the function of an increase of PO. This relationship can be explained by greater disturbances in metabolic stability in type II muscle fibres during exercise, resulting in a decrease of muscle mechanical efficiency and greater increase of heart rate at a given power output. Therefore, MyHC composition has an impact on the oxygen cost of cycling both below and above the LT.

  8. Effect of single physical exercise at 35% VO2 max. intensity on secretion activity of pancreas β-cells and 125J-insulin binding and degradation ability by erythrocyte receptors in children with diabetes mellitus

    International Nuclear Information System (INIS)

    Szczesniak, L.; Rychlewski, T.; Banaszak, F.; Kasprzak, Z.; Walczak, M.

    1994-01-01

    In this report we showed research results of effect of single physical exercise on cycloergometer at 35% VO 2 max. intensity on 125 J-insulin binding and degradation ability by erythrocyte receptors in children with diabetes mellitus, secreting and non-secreting endogenous insulin. Insulin secretion was evaluated by measurement of C-peptide by Biodet test (Serono) of sensitivity threshold at 0.3 μg/ml. We indicated in children non-secreting endogenous insulin (n=32) there is statistically essential lower 125 J-insulin binding with erythrocyte receptor in comparison to children group with C-peptide. Physical exercise on cycloergometer at 35% VO 2 max. intensity caused different reaction in range of physiological indices, like acid-base parameters, level of glucose and 125 J-insulin binding and degradation. In children devoid of endogenous insulin we indicated statistically nonessential changes in 125 J-insulin degradation by non-impaired erythrocytes and by hemolizate, as well. 125 J-insulin binding after physical exercise increased in both groups, though change amplitude was different. Obtained research results allowed us to conclude, in children with I-type diabetes, that in dependence of impairment degree of pancreas βcells sensitivity of insulin receptor and/or number of receptors on erythrocyte surface is different

  9. Oxygen consumption rates in hovering hummingbirds reflect substrate-dependent differences in P/O ratios: carbohydrate as a 'premium fuel'.

    Science.gov (United States)

    Welch, Kenneth C; Altshuler, Douglas L; Suarez, Raul K

    2007-06-01

    The stoichiometric relationship of ATP production to oxygen consumption, i.e. the P/O ratio, varies depending on the nature of the metabolic substrate used. The latest estimates reveal a P/O ratio approximately 15% higher when glucose is oxidized compared with fatty acid oxidation. Because the energy required to produce aerodynamic lift for hovering is independent of the metabolic fuel oxidized, we hypothesized that the rate of oxygen consumption, VO2, should decline as the respiratory quotient, RQ (VCO2/VO2), increases from 0.71 to 1.0 as hummingbirds transition from a fasted to a fed state. Here, we show that hovering VO2 values in rufous (Selasphorus rufus) and Anna's hummingbirds (Calypte anna) are significantly greater when fats are metabolized (RQ=0.71) than when carbohydrates are used (RQ=1.0). Because hummingbirds gained mass during our experiments, making mass a confounding variable, we estimated VO2 per unit mechanical power output. Expressed in this way, the difference in VO2 when hummingbirds display an RQ=0.71 (fasted) and an RQ=1.0 (fed) is between 16 and 18%, depending on whether zero or perfect elastic energy storage is assumed. These values closely match theoretical expectations, indicating that a combination of mechanical power estimates and ;indirect calorimetry', i.e. the measurement of rates of gas exchange, enables precise estimates of ATP turnover and metabolic flux rates in vivo. The requirement for less oxygen when oxidizing carbohydrate suggests that carbohydrate oxidation may facilitate hovering flight in hummingbirds at high altitude.

  10. Effect of Conjugated Linoleic Acid Intake on Endurance Exercise Performance and Anti-fatigue in Student Athletes.

    Science.gov (United States)

    Terasawa, Naoko; Okamoto, Ken; Nakada, Kenta; Masuda, Kazumi

    2017-07-01

    Conjugated linoleic acids (CLA) intake has been reported to reduce body fat mass or increase lean body mass and to improve exercise outcome by modulating testosterone in humans. These reports have studied mostly overweight subjects; few were athletes. Therefore, in this study, the effect of CLA intake on endurance performance and anti-fatigue in student athletes was investigated. A double-blind, crossover study was conducted with 10 male student athletes. Each subject was administered with either CLA (net 0.9 g/day) or a placebo for 14 days. They were subjected to an exercise tolerance test (steady loading) using a cycle ergometer on days 0 and 14. Peak VO 2 was determined for each subject using a graded loading test. The steady loading test was performed with a pedaling exercise load of 50% peak VO 2 for 40 min and then with a load of 70% peak VO 2 until exhaustion. Blood sampling and measurement of critical flicker frequency (CFF) were performed before and after exercise. The rate of perceived exertion (RPE) was measured serially during exercise. In the results, amount of body weight variation significantly increased and amount of body fat percentage variation tended to decrease by CLA intake, it might have an effect by increase in muscle mass. In addition, amount of exercise time variation significantly increased, amount of variation of CFF before and after exercise tended to increase, that of RPE during exercise tended to decrease, and that of creatine phosphokinase before and after exercise tended to decrease in the CLA group. These results suggested that CLA intake for 14 days might have an effect on endurance performance and anti-fatigue in student athletes.

  11. Serum Tumor Necrosis Factor-alpha associates with Myocardial Oxygen Demand and Exercise Tolerance in Postmenopausal Women.

    Science.gov (United States)

    Carter, Stephen J; Bryan, David R; Neumeier, William H; Glasser, Stephen P; Hunter, Gary R

    2018-01-01

    The functional implications of serum tumor necrosis factor-alpha (TNF-α), a marker of oxidative stress, on hemodynamic parameters at rest and during physical exertion are unclear. The aims of this investigation were to examine the independent associations of TNF-α on myocardial oxygen demand at rest and during submaximal exercise, while also evaluating the association of TNF-α on exercise tolerance. Forty, postmenopausal women, provided blood samples and completed a modified-Balke protocol to measure maximal oxygen uptake (VO 2max ). Large artery compliance was measured by pulse contour analyses while rate-pressure product (RPP), an index of myocardial oxygen demand, was measured at rest and during two submaximal workloads (i.e., ≈55% and ≈75% VO 2max ). RPP was calculated by dividing the product of heart rate and systolic blood pressure (via auscultation) by 100. Exercise tolerance corresponded with the cessation of the graded exercise test. During higher-intensity exertion, ≈75% VO 2max , multiple linear regression revealed a positive association ( r = 0.43; p = 0.015) between TNF-α and RPP while adjusting for maximal heart rate, VO 2max , large artery compliance, and percent body fat. Path analyses revealed a significant indirect effect of large artery compliance on exercise tolerance through TNF-α, β = 0.13, CI [0.03, 0.35], indicating greater levels of TNF-α associated with poorer exercise tolerance. These data suggest TNF-α independently associates with myocardial oxygen demand during physical exertion, thus highlighting the utility of higher-intensity efforts to expose important phenomena not apparent at rest. TNF-α also appears to be indirectly associated with the link between large artery compliance and exercise tolerance.

  12. A REVIEW OF STATURE, BODY MASS AND MAXIMAL OXYGEN UPTAKE PROFILES OF U17, U20 AND FIRST DIVISION PLAYERS IN BRAZILIAN SOCCER

    Directory of Open Access Journals (Sweden)

    Cristiano Diniz Da Silva

    2008-09-01

    Full Text Available Investigations in the physiological demands of soccer have identified that a significant percentage of energy production in match performance is provided through the aerobic pathways. It is therefore important to assess maximal oxygen uptake (VO2Max of players in order to evaluate their aerobic fitness status and optimize their physical conditioning. However, it is also important to consider the variation of (VO2Max profiles for soccer players, with differences having been identified in terms of playing position as well as playing style. This paper reviews the academic literature between 1996 and 2006 and reports on the methodologies employed and the values obtained for stature, body mass and (VO2Max profiles of soccer players of different positions in professional Brazilian clubs at U-17, U-20 and First Division levels. Indirect measurements accounted for the majority of tests conducted at U-17 (70% and U-20 (84.6% levels whereas at First Division level almost half of the (VO2Max evaluations were performed by direct measurements (47.8%. The mean (VO2Max profiles obtained for outfield players in U-17 was 56.95 ± 3.60 ml·kg-1·min-1, 58.13 ± 3.21 ml·kg-1·min-1 for U-20 players and 56.58 ± 5.03 ml·kg-1·min-1 for First Division players. In Brazil, the U-20 players appear to have highest VO2Max values, however the profiles reported for all outfield positions in U-17 and First Division levels are often lower than those reported for the same category of players from other countries. This may be a reflection of the style of play used in Brazilian soccer. This is further emphasized by the fact that the playing position with the highest VO2Max values was the external defenders whereas most findings from studies performed in European soccer indicate that midfielders require the highest VO2Max values.

  13. Oxygen delivery and consumption during on-bypass cabg in htea and central analgesia

    Directory of Open Access Journals (Sweden)

    Віталій Олексійович Собокарь

    2015-04-01

    Full Text Available Objective. Despite some advantages, the use of high thoracic epidural anesthesia (HTEA during on-bypass cardiac surgery may be discouraged by fear of adverse hemodynamic effects and associated disturbances of oxygen delivery.Aim. To compare oxygen delivery and consumption during on-bypass coronary artery bypass grafting in settings of HTEA and central analgesia (CA.Methods. 132 patients were assigned into two groups – study group (n=85, where the surgery was performed under HTEA and control group (n=47 - where the surgery was carried out under CA. Using data of transesophageal cardiac ultrasound and blood oximetry blood oxygen delivery (DO2, oxygen consumption (VO2, oxygen extraction coefficient (CEO2 were calculated at four stages of the surgery: after induction, sternotomy, cardiopulmonary bypass and at the end of the surgery.Results. In the initial stages of the surgery DO2 and VO2 were reduced relative to reference values with a tendency to increase in the course of the operation and achievement of the normal or supernormal level (VO2, study group in the final stage. The decrease was due to moderate hypodynamic circulation and hemodilution. After sternotomy DO2 in the study group was higher than that of the control: 356 (279; 458 vs 317±89 ml·min-1·m-2, (р=0,021. After cardiopulmonary bypass oxygen saturation of venous blood (SatvO2, in the study group was 71 ± 9 % compared with 68 ± 10 % in the control group. At the end of the surgery SatvO2 in the study group was 71 (66; 75 vs 59 (53; 70 % in the control (р = 0,005 and oxygen tension of venous blood (РvО2 was correspondingly 39 ± 6 and 33 (30; 38 mm Hg (р = 0,027. Despite the decrease in DO2 and VO2, oxygen extraction indices - CEO2, pvO2, SatvO2, and remained within the reference range, except that of the control group at the end of the surgery. Furthermore, at no stage lactate rise or acid-base deviations was observed in the both groups.Conclusions. In patients operated

  14. No impaired hemoglobin oxygenation in forearm muscles of patients with chronic CRPS-1.

    Science.gov (United States)

    Brunnekreef, Jaap J J; Oosterhof, Jan; Wolff, André P; Crul, Ben J P; Wilder-Smith, Oliver H G; Oostendorp, Rob A B

    2009-01-01

    Physiotherapy is considered an important treatment option in patients with upper limb complex regional pain syndrome type-1 (CRPS-1). In case of chronic CRPS-1, exercise therapy of the affected limb forms an important part of the physiotherapeutic program. We investigated whether muscle loading in chronic CRPS-1 patients is associated with impairments in muscle circulation of the forearm of the affected limb. Thirty patients with chronic CRPS-1 unilaterally affecting their upper limbs, and 30 age-matched and sex-matched control participants were included in this study. Local muscle blood flow and hemoglobin oxygenation were measured by near infrared spectroscopy within the muscles of the forearm at rest, after 1-minute isometric handgrip exercises, and after arterial occlusion. Main outcome parameters were: local muscle blood flow, O2 consumption (mVO2), and postischemic reoxygenation (ReOx). We found no differences in baseline muscle blood flow, mVO2, and ReOx between the affected CRPS-1, unaffected CRPS-1, and control arms. After exercise, mVO2 of the affected CRPS-1 arms was not different from the clinically unaffected CRPS-1 arms. Furthermore, in comparison with the control arms, unaffected CRPS-1 arms showed no difference in mVO2 or ReOx. Muscle loading does not seems to be related to impairments in muscle oxygen uptake in forearm muscles of upper limbs affected by chronic CRPS-1. Our results suggest that exercise therapy can be safely used in physiotherapeutic training programs for chronic CRPS-1 of the upper limb.

  15. [Pregnancy toxemia. Oxygen input/extraction in preeclampsia-eclampsia].

    Science.gov (United States)

    Rodríguez-Badillo, R F; Noriega-R, T; Audifred-Salomón, J R; García-Lara, E

    1996-07-01

    We tried to determine if the toxemia of pregnancy has during its clinical evolution a dependent DO2/VO2 relationship and determine its critical DO2 and finally define if this has a prognostic value. There were included patients with diagnosis of preeclampsia/eclampsia that were enter at the Intensive Care Unit for treatment and monitoring. It was placed a catheter in the pulmonary artery and it was determine the cardiac output and by means of standard formulas the DO2, VO2 and EO2 were calculated. The critical delivery of oxygen was stablished in agree at the Gutiérrez's method. At the same time it was monitorised the base excess which was gotten from arterial and venous blood gases. 36 patients (29 with preclampsia and 7 with eclampsia) were included, with a mean age of 26.3 years old. The mean gestational age was 36.1 weeks. The critical delivery for preeclamptic patients was stablished in 924 mL/min and at the eclamptic patients in 830 mL/min: both values had prognostic correlation with survival and nonsurvival patients (p 30%. The toxemia of pregnancy had a behaviour like state accompaniment of a dependent DO2/VO2 relationship causing an important oxygen deficient that was improved was improved in the survival patients that reach values over the critical delivery. These facts suggesting the presence of a metabolic blockade in variable degree that can improve or increase agree a therapeutic manipulations in the critic DO2.

  16. Análise de lesão muscular e comportamento do vo2máx entre um programa de treinamento de corrida em piscina funda e corrida em terra

    Directory of Open Access Journals (Sweden)

    Alecsandra Pinheiro Vendrusculo

    2014-12-01

    Full Text Available Objetivo: avaliar e comparar a ocorrência de lesão muscular e o comportamento do consumo máximo de oxigênio (VO2máx entre um programa de treinamento de corrida em terra (CT e um programa de treinamento de corrida em piscina funda (CPF. Método: participaram do estudo 14 indivíduos não treinados. O treinamento durou 12 semanas, três vezes na semana. Analisou-se o comportamento do VO2máx pré e pós-treinamento. Para a análise de lesão muscular utilizou-se a enzima creatina quinase (CK pré, logo após, pós 24h e 48h da sessão, a cada quatro semanas e a ultrassonografia (US a cada quatro semanas. Resultados: Quando se analisou o comportamento do VO2máx, verificou-se diferença entre os valores pré e pós-treinamento, mas não houve diferença entre os grupos. Quanto à CK, verificou-se diferença entre os grupos na medida 24hs após, o que não foi verificado nas outras medidas. Para o grupo CT, somente nas coletas dois e quatro verificou-se diferença entre as medidas 24hs após e 48hs após, mas não ocorreram diferenças significativas entre as medidas e nem entre os grupos. Na US, nenhum dos grupos apresentou diferença significativa entre os exames, mas no grupo CT apareceram duas lesões na terceira coleta. Considerações finais: concluiu-se que as duas modalidades de treinamento proporcionam uma melhora na aptidão cardiorrespiratória e, embora não tenha ocorrido diferença significativa em algumas coletas de CK entre os grupos, a CT provocou maiores aumentos na concentração sanguínea de CK, sugerindo que o meio líquido pode ser o mais indicado para proteger o sistema musculoesquelético.

  17. Aerobic fitness and metabolic health in children: A clinical validation of directly measured maximal oxygen consumption versus performance measures as markers of health.

    Science.gov (United States)

    Aadland, Eivind; Kvalheim, Olav Martin; Rajalahti, Tarja; Skrede, Turid; Resaland, Geir Kåre

    2017-09-01

    High aerobic fitness is consistently associated with a favorable metabolic health profile in children. However, measurement of oxygen uptake, regarded as the gold standard for evaluating aerobic fitness, is often not feasible. Thus, the aim of the present study was to perform a clinical validation of three measures of aerobic fitness (peak oxygen consumption [VO 2peak ] and time to exhaustion [TTE] determined from a graded treadmill protocol to exhaustion, and the Andersen intermittent running test) with clustered metabolic health in 10-year-old children. We included 93 children (55 boys and 38 girls) from Norway during 2012-2013 in the study. Associations between aerobic fitness and three different composite metabolic health scores (including lipoprotein subgroup particle concentrations, triglyceride, glucose, systolic blood pressure, and waist-to-height ratio) were determined by regression analyses adjusting for sex. The relationships among the measures of aerobic fitness were r  = 0.78 for VO 2peak vs. TTE, r  = 0.63 for VO 2peak vs. the Andersen test, and r  = 0.67 for TTE vs. the Andersen test. The Andersen test showed the strongest associations across all markers of metabolic health ( r  = - 0.45 to - 0.31, p  fitness do not stand back as markers of metabolic health status in children, compared to VO 2peak . This is of great importance as good field tests provide opportunities for measuring aerobic fitness in many settings where measuring VO 2peak are impossible.

  18. Electrostimulation improves muscle perfusion but does not affect either muscle deoxygenation or pulmonary oxygen consumption kinetics during a heavy constant-load exercise.

    Science.gov (United States)

    Layec, Gwenael; Millet, Grégoire P; Jougla, Aurélie; Micallef, Jean-Paul; Bendahan, David

    2008-02-01

    Electromyostimulation (EMS) is commonly used as part of training programs. However, the exact effects at the muscle level are largely unknown and it has been recently hypothesized that the beneficial effect of EMS could be mediated by an improved muscle perfusion. In the present study, we investigated rates of changes in pulmonary oxygen consumption (VO(2p)) and muscle deoxygenation during a standardized exercise performed after an EMS warm-up session. We aimed at determining whether EMS could modify pulmonary O(2) uptake and muscle deoxygenation as a result of improved oxygen delivery. Nine subjects performed a 6-min heavy constant load cycling exercise bout preceded either by an EMS session (EMS) or under control conditions (CONT). VO(2p) and heart rate (HR) were measured while deoxy-(HHb), oxy-(HbO(2)) and total haemoglobin/myoglobin (Hb(tot)) relative contents were measured using near infrared spectroscopy. EMS significantly increased (P < 0.05) the Hb(tot) resting level illustrating a residual hyperaemia. The EMS priming exercise did not affect either the HHb time constant (17.7 +/- 14.2 s vs. 13.1 +/- 2.3 s under control conditions) or the VO(2p) kinetics (time-constant = 18.2 +/- 5.2 s vs. 15.4 +/- 4.6 s under control conditions). Likewise, the other VO(2p) parameters were unchanged. Our results further indicated that EMS warm-up improved muscle perfusion through a residual hyperaemia. However, neither VO(2p) nor [HHb] kinetics were modified accordingly. These results suggest that improved O(2) delivery by residual hyperaemia induced by EMS does not accelerate the rate of aerobic metabolism during heavy exercise at least in trained subjects.

  19. Physico - chemical investigation on Co(II), Ni(II), Cu(II), Zn(II), Cd(II), UO2+2 and VO+2 ions-O-(-N-3,5-dichloro-α-pyridone imino)

    International Nuclear Information System (INIS)

    Mathur, Praveen; Trivedi, Pradeep; Mehta, R.K.

    1983-01-01

    Studies on the interaction of newly synthesised ligand, O-(N-3, 5-dichloro-α-pyridone imino) benzene sulphonic acid (H 2 PB) with Co(II), Ni(II), Cu(II), Zn(II), Cd(II), UO 2 +2 and VO +2 have been carried out potentiometrically. Many physico-chemical studies on thermodynamics, elemental analysis, molecular weight, magnetic moment, conductance, electronic and IR spectra have also been made on the solid chelates and their adducts. The dissociation constants of H 2 PB and stabilities of its bivalent chelates have been evaluated potentiometrically at 25deg, 35deg and 45degC in aqueous medium (0.01M, 0.05M and 0.1M NaClO 4 ) by Bjerrum's method. The stability sequence is in agreement with the Irving-William's rule. (author)

  20. Oxygen uptake during peak graded exercise and single-stage fatigue tests of wheelchair propulsion in manual wheelchair users and the able-bodied.

    Science.gov (United States)

    Keyser, R E; Rodgers, M M; Gardner, E R; Russell, P J

    1999-10-01

    To determine if a single-stage, submaximal fatigue test on a wheelchair ergometer would result in higher than expected energy expenditure. An experimental survey design contrasting physiologic responses during peak graded exercise tests and fatigue tests. A rehabilitation science laboratory that included a prototypical wheelchair ergometer, open-circuit spirometry system, and heart rate monitor. Nine able-bodied non-wheelchair users (the NWC group: 6 men and 3 women, mean +/- SD age 30 +/- 7yrs) and 15 manual wheelchair users (the WC group: 12 men and 3 women, age 40 +/- 9yrs, time in wheelchair 16 +/- 9yrs). No subject had any disease, medication regimen, or upper body neurologic, orthopedic, or other condition that would limit wheelchair exercise. Peak oxygen uptake (VO2) for graded exercise testing and during fatigue testing, using a power output corresponding to 75% peak aerobic capacity on graded exercise test. In the WC group, VO2 at 6 minutes of fatigue testing was not significantly different from peak VO2. In the NWC group, VO2 was similar to the expected level throughout fatigue testing. Energy expenditure was higher than expected in the WC group but not in the NWC group. Fatigue testing may provide a useful evaluation of cardiorespiratory status in manual wheelchair users.

  1. Hepatic blood flow and splanchnic oxygen consumption in patients with liver failure. Effect of high-volume plasmapheresis.

    Science.gov (United States)

    Clemmesen, J O; Gerbes, A L; Gülberg, V; Hansen, B A; Larsen, F S; Skak, C; Tygstrup, N; Ott, P

    1999-02-01

    Liver failure represents a major therapeutic challenge, and yet basic pathophysiological questions about hepatic perfusion and oxygenation in this condition have been poorly investigated. In this study, hepatic blood flow (HBF) and splanchnic oxygen delivery (DO2, sp) and oxygen consumption (VO2,sp) were assessed in patients with liver failure defined as hepatic encephalopathy grade II or more. Measurements were repeated after high-volume plasmapheresis (HVP) with exchange of 8 to 10 L of plasma. HBF was estimated by use of constant infusion of D-sorbitol and calculated according to Fick's principle from peripheral artery and hepatic vein concentrations. In 14 patients with acute liver failure (ALF), HBF (1.78 +/- 0.78 L/min) and VO2,sp (3.9 +/- 0.9 mmol/min) were higher than in 11 patients without liver disease (1.07 +/- 0.19 L/min, P HVP, HBF increased from 1.67 +/- 0.72 to 2.07 +/- 1.11 L/min (n=11) in ALF, and from 1.89 +/- 1.32 to 2.34 +/- 1.54 L/min (n=7) in AOCLD, P HVP. Blood flow was redirected to the liver as the systemic vascular resistance index increased (1,587 +/- 650 vs. 2, 020 +/- 806 Dyne. s. cm-5. m2, P HVP, but as cardiac output increased from 9.1 +/- 2.8 to 10.1 +/- 2.9 L/min (P HVP (n=18), DO2,sp increased by 15% (P HVP. Changes of ET-1 were positively correlated with changes in HBF (P HVP (P HVP did not correlate. Our data suggest that liver failure is associated with increased HBF and VO2, sp. HVP further increased HBF and DO2,sp but VO2,sp was unchanged, indicating that splanchnic hypoxia was not present.

  2. Effect of germanium doping on the annealing characteristics of oxygen and carbon-related defects in Czochralski silicon

    International Nuclear Information System (INIS)

    Londos, C. A.; Andrianakis, A.; Sgourou, E. N.; Emtsev, V.; Ohyama, H.

    2010-01-01

    This paper is devoted to the annealing studies of defects produced in carbon-rich Ge-doped Czochralski-grown Si (Cz-Si) by 2 MeV electron irradiation. The annealing temperature of vacancy-oxygen (VO) complexes, carbon interstitial-oxygen interstitial (C i O i ), and carbon interstitial-carbon substitutional (C i C s ) pairs as well as the formation temperature of vacancy-two oxygen (VO 2 ) complexes are monitored as a function of Ge concentration. It has been established that the annealing of C i O i and C i C s defects remains practically unaffected by the Ge presence, whereas the annealing temperature of VO defects and the formation temperature of VO 2 complexes are substantially lowered at Ge concentrations larger than 1x10 19 cm -3 . The hydrostatic component of elastic strains introduced by Ge atoms in the Si crystal lattice was calculated. It appears to be very small, at least insufficient to exert a pronounced effect upon the annealing behavior of radiation-produced defects. This conclusion is in line with what is observed for the C i O i and C i C s species. In the case of VO, whose annealing process in Cz-Si is concurrently conducted by two reaction paths VO+O i →VO 2 and VO+Si I →O i , we suggest that the latter reaction in Ge-doped Cz-Si is enhanced by emitting self-interstitials (Si I ) from loosely bound self-interstitial clusters predominantly formed around Ge impurity atoms. As a result, the liberation of self-interstitials at lower annealing temperatures leads to an enhanced annealing of VO defects. An enhanced formation of VO 2 complexes at lower temperatures is also discussed in terms of other reactions running in parallel with the reaction VO+Si I →O i .

  3. The effects of swimming and running on energy intake during 2 hours of recovery.

    Science.gov (United States)

    Lambert, C P; Flynn, M G; Braun, W A; Boardley, D J

    1999-12-01

    To determine energy intake in the 2 hrs after swimming (S) and running (R) at the same relative exercise intensity and duration (71.8 +/- 2.5% VO2max; 45 min) to evaluate whether a difference in recovery energy intake could explain the greater body fat observed in swimmers relative to runners. this was a randomized crossover design. running exercise was conducted on a motorized treadmill (Quinton) while swimming was conducted in a 45.7 m pool. eight well-trained competitive male triathletes participated in this investigation. subjects were blinded to the purpose of the study and swam and ran on separate occasions for 45 min at 71.8 +/- 2.5% of VO2max. Subjects were then placed in a room with a variety of foods and beverages for 2 hrs after R and S. energy intake (kJ/2 hrs and kcal/2 hrs) was determined by weighing and measuring the food remaining in the room after 2 hrs of postexercise recovery. Expired gases, heart rates, and Ratings of Perceived Exertion were obtained at 15 min intervals throughout exercise. Blood samples for serum glucose and lactate were obtained preexercise and immediately, 15 min, and 135 min postexercise. Perceived hunger and thirst ratings were obtained after the subjects were seated in the room containing the food. Serum glucose was significantly (p energy intake (4584 +/- 611 kJ/2 hrs; 1095 +/- 146 kcal/2 hrs for R and 4383 +/- 484 kJ/2 hrs; 1047 +/- 116 kcal for S) or blood lactate. The type of exercise, swimming or running, did not significantly influence energy intake during 2 hours of postexercise recovery.

  4. Oxygen consumption during exercise in a heated pool.

    Science.gov (United States)

    Kirby, R L; Sacamano, J T; Balch, D E; Kriellaars, D J

    1984-01-01

    The heated hydrotherapy pool is a common exercise site for patients with painful musculoskeletal conditions. Oxygen consumption of swimming is 87 to 89% of maximum in postmyocardial infarction patients according to one recent investigation. We studied 13 able-bodied subjects to test the hypothesis that enough energy could be expended during various forms of hydrotherapy to produce both an aerobic training effect and a risk to patients with coronary artery disease. Oxygen consumption (VO2) was measured in six settings: resting supine; resting seated shoulder deep in the pool (36C); walking at comfortable speed in chest-deep water; running at the fastest speed possible in chest-deep water; using hand paddles; and running in place at shoulder depth. The mean VO2 expressed in ml/kg/min (and metabolic equivalents) were 4.91 (1.00), 4.93 (1.02), 9.34 (2.01), 27.79 (6.23), 18.25 (4.30) and 29.11 (7.09) respectively, suggesting that the more vigorous exercises stress aerobic capacity heavily but not excessively.

  5. Comparison of oxygen uptake during and after the execution of resistance exercises and exercises performed on ergometers, matched for intensity

    Directory of Open Access Journals (Sweden)

    Vilaça-Alves José

    2016-12-01

    Full Text Available The aim of this study was to compare the values of oxygen uptake (VO2 during and after strength training exercises (STe and ergometer exercises (Ee, matched for intensity and exercise time. Eight men (24 ± 2.33 years performed upper and lower body cycling Ee at the individual’s ventilatory threshold (VE/VCO2. The STe session included half squats and the bench press which were performed with a load at the individual blood lactate concentration of 4 mmol/l. Both sessions lasted 30 minutes, alternating 50 seconds of effort with a 10 second transition time between upper and lower body work. The averaged overall VO2 between sessions was significantly higher for Ee (24.96 ± 3.6 ml·kg·min-1 compared to STe (21.66 ± 1.77 ml·kg·min-1 (p = 0.035, but this difference was only seen for the first 20 minutes of exercise. Absolute VO2 values between sessions did not reveal differences. There were more statistically greater values in Ee compared to STe, regarding VO2 of lower limbs (25.44 ± 3.84 ml·kg·min-1 versus 21.83 ± 2·24 ml·kg·min-1; p = 0.038 and upper limbs (24.49 ± 3.84 ml·kg·min-1 versus 21.54 ± 1.77 ml·kg·min-1; p = 0.047. There were further significant differences regarding the moment effect (p<0.0001 of both STe and Ee sessions. With respect to the moment × session effect, only VO2 5 minutes into recovery showed significant differences (p = 0.017. In conclusion, although significant increases in VO2 were seen following Ee compared to STe, it appears that the load/intensity, and not the material/equipment used for the execution of an exercise, are variables that best influence oxygen uptake.

  6. Effect of FiO2 in the measurement of VO2 and VCO2 using the E-COXV metabolic monitor.

    Science.gov (United States)

    Ferreruela, M; Raurich, J M; Llompart-Pou, J A; Colomar, A; Ayestarán, I

    2017-11-01

    We evaluated the effect of changes in FiO 2 on the bias and accuracy of the determination of oxygen consumption (V˙O 2 ) and carbon dioxide production (V˙CO 2 ) using the E-COVX monitor in patients with mechanical ventilation. Descriptive of concordance. Intensive Care Unit. Patients with mechanical ventilation. We measured V˙O 2 and V˙CO 2 using the E-COVX monitor. Values recorded were the average in 5min. Two groups of 30 patients. We analyzed: 1) the reproducibility in the measurement of V˙O 2 and V˙CO 2 at FiO 2 0.4, and 2) the effect of the changes in FiO 2 on the measurement of V˙O 2 and V˙CO 2 . Statistical analysis was performed using Bland and Altman test. Bias and accuracy. 1) FiO 2 0.4 reproducibility: The bias in the measurement of V˙O 2 and V˙CO 2 was 1.6 and 2.1mL/min, respectively, and accuracy was 9.7 to -8.3% and 7.2 to -5.2%, respectively, and 2) effect of FiO 2 on V˙O 2 : The bias of V˙O 2 measured at FiO 2 0.4 and 0.6 was -4.0mL/min and FiO 2 0.4 and 0.8 was 5.2mL/min. Accuracy between FiO 2 0.4 and 0.6 was 11.9 to -14.1%, and between FiO 2 0.4 and 0.8 was 43.9 to -39.7%. The E-COVX monitor evaluates V˙O 2 and V˙CO 2 in critical patients with mechanical ventilation with a clinically acceptable accuracy until FiO 2 0.6. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  7. Neuromuscular blockade of slow twitch muscle fibres elevates muscle oxygen uptake and energy turnover during submaximal exercise in humans

    DEFF Research Database (Denmark)

    Krustrup, Peter; Secher, Niels; Relu, Mihai U.

    2008-01-01

    We tested the hypothesis that a greater activation of fast-twitch (FT) fibres during dynamic exercise leads to a higher muscle oxygen uptake (VO2 ) and energy turnover as well as a slower muscle on-kinetics. Subjects performed one-legged knee-extensor exercise for 10 min at an intensity of 30 W...... without (CON) and with (CUR) arterial injections of the non-depolarizing neuromuscular blocking agent cisatracurium. In CUR, creatine phosphate (CP) was unaltered in slow twitch (ST) fibres and decreased (P fibres, whereas in CON, CP decreased (P ... at a contraction frequency of 1 Hz, and that the muscle VO2 kinetics is slowed by FT fibre activation....

  8. Coffee intake.

    Science.gov (United States)

    Cornelis, Marilyn C

    2012-01-01

    Coffee is one of the most widely consumed beverages in the world. Its widespread popularity and availability has fostered public health concerns of the potential health consequences of regular coffee consumption. Epidemiological studies of coffee intake and certain health outcomes have been inconsistent. The precise component of coffee potentially contributing to development of these conditions also remains unclear. One step toward addressing the challenges in studying the impact coffee has on health is a better understanding of the factors contributing to its consumption and physiological effects. This chapter focuses on those factors that are genetically determined and briefly summarizes progress in applying this knowledge to epidemiological studies of coffee and disease. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Clinical safety and parameters of maximum oxygen uptake (Vo/sub 2/ max) testing in pakistani patients with heart failure

    International Nuclear Information System (INIS)

    Hussain, S.; Kayani, A.M.

    2015-01-01

    To determine the parameters of maximum oxygen uptake (VO2 max) in a Pakistani systolic heart failure cohort and its safety in a clinical setting. Study Design: Descriptive study. Place and Duration of Study: Armed Forces Institute of Cardiology, National Institute of Heart Diseases, Rawalpindi, from June 2011 to January 2013. Methodology: Maximum oxygen uptake test was performed in patients with severe heart failure, who could perform the VO2 max treadmill test. Age, Body Mass Index (BMI) ejection fraction, VO2 max and respiratory exchange ratios and their correlations were determined. Results: Out of 135 patients, 77% (n=104) were males, with a mean age of 45.9 ± 15.7 years. Weight of patients ranged from 30 kg to 107 kg (mean 63.29 ± 13.6 kg); mean BMI was 23.16 ± 4.56 kg/m2. All patients presented with either NYHA class of III (50.3%; n=68) or IV (49.7%; n=67); mean ejection fraction was 22.54 ± 5.7% (10 - 35%, IQ:20 - 25). The VO2 max of the patients ranged from 3 to 32 ml/kg/minute (mean 12.85 ± 4.49 ml/kg/minute). Respiratory exchange ratio was over 1 for all patients (1.12 - 1.96, mean = 1.36 ± 0.187). There was a negative correlation with age (r = -0.204; p = 0.028) whereas a positive correlation was found with exercise time (r = 0.684; p = 0.000), hemoglobin (r = 0.190; p = 0.047) and ejection fraction (r = 0.187 ; p = 0.044). Conclusion: Cardiopulmonary exercise testing in a high-risk heart failure cohort is safe and provides information beyond the routine clinical evaluation of heart failure patients. (author)

  10. The effect of post-exercise drink macronutrient content on appetite and energy intake.

    Science.gov (United States)

    Clayton, David J; Stensel, David J; Watson, Phillip; James, Lewis J

    2014-11-01

    Carbohydrate and protein ingestion post-exercise are known to facilitate muscle glycogen resynthesis and protein synthesis, respectively, but the effects of post-exercise nutrient intake on subsequent appetite are unknown. This study aimed to investigate whether protein induced satiety that has been reported at rest was still evident when pre-loads were consumed in a post-exercise context. Using a randomised, double blind, crossover design, 12 unrestrained healthy males completed 30 min of continuous cycling exercise at ~60% VO2peak, followed by five, 3 min intervals at ~85% VO2peak. Ten min post-exercise, subjects consumed 500 ml of either a low energy placebo (15 kJ) (PLA); a 6% whey protein isolate drink (528 kJ) (PRO); or a 6% sucrose drink (528 kJ) (CHO). Sixty min after drink ingestion, a homogenous ad-libitum pasta lunch was provided and energy intake at this lunch was quantified. Subjective appetite ratings were measured at various stages of the protocol. Energy consumed at the ad-libitum lunch was lower after PRO (5831 ± 960 kJ) than PLA (6406 ± 492 kJ) (P0.315). Considering the post-exercise drink, total energy intake was not different between trials (P=0.383). There were no differences between trials for any of the subjective appetite ratings. The results demonstrate that where post-exercise liquid protein ingestion may enhance the adaptive response of skeletal muscle, this may be possible without affecting gross energy intake relative to consuming a low energy drink. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Pain severity is associated with muscle strength and peak oxygen uptake in adults with fibromyalgia

    Directory of Open Access Journals (Sweden)

    Hooten WM

    2014-05-01

    Full Text Available W Michael Hooten,1,2 Jolene M Smith,3 Jason S Eldrige,1 David A Olsen,3 W David Mauck,1 Susan M Moeschler11Department of Anesthesiology, 2Department of Psychiatry and Psychology, Mayo Clinic College of Medicine, 3Mayo School of Graduate Medical Education, Rochester, MN, USABackground: The associations between pain, lower extremity strength, and aerobic conditioning have not been widely investigated in adults with fibromyalgia (FM. The principle objective of this study was to investigate the relationship between pain severity and knee strength in patients seeking treatment for FM. A secondary objective was to investigate the relationship between pain scores and aerobic conditioning.Methods: Three measures of knee strength (isokinetic extensor, isokinetic flexor, isometric extensor were quantified in the dominant leg of 69 adults with FM using a dynamometer at speeds of 60 degrees per second (60°/s and 180°/s. Peak oxygen uptake (VO2 was assessed using a cycle ergometer, and pain was assessed using the pain severity subscale of the Multidimensional Pain Inventory.Results: In univariable linear regression analyses using pain severity as the dependent variable, lesser values of isokinetic knee extensor strength at 60°/s (P=0.041 and 180°/s (P=0.010, isokinetic knee flexor strength at 60°/s (P=0.028 and 180°/s (P=0.003, and peak VO2 uptake (P=0.031 were predictive of greater pain severity scores. In multiple variable linear regression models adjusted for age, sex, body mass index, and opioid use, the following associations retained statistical significance; isokinetic knee extensor strength at 60°/s (P=0.020 and 180°/s (P=0.003, isokinetic knee flexor strength at 60°/s (P=0.015 and 180°/s (P=0.001, and peak VO2 uptake (P=0.014. However, no significant associations were found between pain severity and isometric knee extensor strength.Conclusion: The main findings from this study were that lesser values of isokinetic knee strength and peak VO

  12. Measurement of Diaphragmatic Blood Flow and Oxygen Consumption in the Dog by the Kety-Schmidt Technique

    Science.gov (United States)

    Rochester, Dudley F.

    1974-01-01

    To assess energy expenditure of the diaphragm directly, a method was devised for percutaneous catheterization of the left inferior phrenic vein in dogs. Necropsy studies, including retrograde injection of india ink and measurement of radioactivity in diaphragmatic muscle strips, suggested that the territory drained by the inferior phrenic vein was uniformly perfused, and that there were no major anastomoses between this bed and adjacent ones. Diaphragmatic blood flow (˙Q di) was calculated from the integrated diaphragmatic arteriovenous difference of 85Kr by the Kety-Schmidt technique. Diaphragmatic oxygen consumption (˙Vo2 di) was determined as the product of ˙Q di and the diaphragmatic arteriovenous oxygen content difference [(A-V)O2 di]. When lightly anesthetized dogs breathed quietly, ˙Q di was 22±SD 6 ml/min/100 g, (A-V)O2 di was 6.1±SD 2.5 ml/100 ml, and ˙VO2 di averaged 1.2±SD 0.3 ml/min/100 g. This represented 1.0±SD 0.2% of total body oxygen consumption. ˙VO2 di remained relatively constant during quiet breathing, whereas ˙Q di varied directly with cardiac output and reciprocally with (A-V)O2 di. The oxygen consumption of the noncontracting diaphragm was 60±SD 20% of the level measured during quiet breathing. The energy expended by the diaphragm to support simple hyperventilation was small. A 100% increase in minute ventilation, induced by inhalation of 5% CO2 in 21% or 14% O2, increased ˙Q di 13%, (A-V)O2 di 19%, and ˙VO2 di 40%. The diaphragm consumed 0.13±SD 0.09 ml O2 for each additional liter of ventilation. In four dogs, pneumonia appeared to increase ˙VO2 both by increasing minute ventilation and by increasing the energy cost per liter of ventilation. PMID:4825221

  13. In healthy elderly postmenopausal women variations in BMD and BMC at various skeletal sites are associated with differences in weight and lean body mass rather than by variations in habitual physical activity, strength or VO2max.

    Science.gov (United States)

    Schöffl, I; Kemmler, W; Kladny, B; Vonstengel, S; Kalender, W A; Engelke, K

    2008-01-01

    The objective of this study was an integrated cross-sectional investigation for answering the question whether differences in bone mineral density in elderly postmenopausal women are associated with differences in habitual physical activity and unspecific exercise levels. Two hundred and ninety nine elderly women (69-/+3 years), without diseases or medication affecting bone metabolism were investigated. The influence of weight, body composition and physical activity on BMD was measured at multiple sites using different techniques (DXA, QCT, and QUS). Physical activity and exercise level were assessed by questionnaire, maximum strength of the legs and aerobic capacity. Variations in physical activity or habitual exercise had no effect on bone. The only significant univariate relation between strength/VO(2)max and BMD/BMC that remained after adjusting for confounding variables was between arm BMD (DXA) and hand-grip strength. The most important variable for explaining BMD was weight and for cortical BMC of the femur (QCT) lean body mass. Weight and lean body mass emerge as predominant predictors of BMD in normal elderly women, whereas the isolated effect of habitual physical activity, unspecific exercise participation, and muscle strength on bone parameters is negligible. Thus, an increase in the amount of habitual physical activity will probably have no beneficial impact on bone.

  14. Nanoscale Phase Separation and Lattice Complexity in VO2: The Metal–Insulator Transition Investigated by XANES via Auger Electron Yield at the Vanadium L23-Edge and Resonant Photoemission

    Directory of Open Access Journals (Sweden)

    Augusto Marcelli

    2017-12-01

    Full Text Available Among transition metal oxides, VO2 is a particularly interesting and challenging correlated electron material where an insulator to metal transition (MIT occurs near room temperature. Here we investigate a 16 nm thick strained vanadium dioxide film, trying to clarify the dynamic behavior of the insulator/metal transition. We measured (resonant photoemission below and above the MIT transition temperature, focusing on heating and cooling effects at the vanadium L23-edge using X-ray Absorption Near-Edge Structure (XANES. The vanadium L23-edges probe the transitions from the 2p core level to final unoccupied states with 3d orbital symmetry above the Fermi level. The dynamics of the 3d unoccupied states both at the L3- and at the L2-edge are in agreement with the hysteretic behavior of this thin film. In the first stage of the cooling, the 3d unoccupied states do not change while the transition in the insulating phase appears below 60 °C. Finally, Resonant Photoemission Spectra (ResPES point out a shift of the Fermi level of ~0.75 eV, which can be correlated to the dynamics of the 3d// orbitals, the electron–electron correlation, and the stability of the metallic state.

  15. An experimental and theoretical study on the interaction of DNA and BSA with novel Ni2 +, Cu2 + and VO2 + complexes derived from vanillin bidentate Schiff base ligand

    Science.gov (United States)

    Dostani, Morteza; Kianfar, Ali Hossein; Mahmood, Wan Ahmad Kamil; Dinari, Mohammad; Farrokhpour, Hossein; Sabzalian, Mohammad R.; Abyar, Fatemeh; Azarian, Mohammad Hossein

    2017-06-01

    In this investigation, the structure of bidentate N,N-Schiff base ligand of vanillin, (E)-4-(((2-amino-5-nitrophenyl)imino)methyl)-2-methoxyphenol (HL) was determined by single crystal X-ray diffraction. The interaction of new [CuL2], [NiL2] and [VOL2] complexes with DNA and BSA was explored through UV-Vis and fluorescence spectroscopy. The electronic spectra changes displayed an isosbestic point for the complexes upon titration with DNA. The Kb values for the complexes [CuL2], [NiL2] and [VOL2] were 2.4 × 105, 1.9 × 105 and 4.2 × 104, respectively. [CuL2] complex was bound more toughly than [NiL2] and [VOL2] complexes. These complexes had a significant interaction with Bovine Serum Albumin (BSA) and the results demonstrated that the quenching mechanism was a static procedure. Also, the complexes interacted with BSA by more than one binding site (n > 1). Finally, the theoretical studies were performed using the docking method to calculate the binding constants and recognize the binding site of the DNA and BSA with the complexes. The ligand and complexes including Ni2 +, Cu2 + and VO2 + ions were colonized by fungal growth.

  16. Arm Crank and Wheelchair Ergometry Produce Similar Peak Oxygen Uptake but Different Work Economy Values in Individuals with Spinal Cord Injury

    Directory of Open Access Journals (Sweden)

    Tom Tørhaug

    2016-01-01

    Full Text Available Objective. To study whether values for peak oxygen uptake (VO2peak and work economy (WE at a standardized workload are different when tested by arm crank ergometry (ACE and wheelchair ergometry (WCE. Methods. Twelve paraplegic men with spinal cord injury (SCI in stable neurological condition participated in this cross-sectional repeated-measures study. We determined VO2peak and peak power output (POpeak values during ACE and WCE in a work-matched protocol. Work economy was tested at a standardized workload of 30 Watts (W for both ACE and WCE. Results. There were no significant differences in VO2peak (mL·kg−1·min−1 between ACE (27.3±3.2 and WCE (27.4±3.8 trials, and a Bland-Altman plot shows that findings are within 95% level of agreement. WE or oxygen consumption at 30 W (VO2-30W was significantly lower during WCE compared to ACE (P<0.039. Mean (95% CI POpeak (W were 130 (111–138 and 100 (83–110 during ACE and WCE, respectively. Conclusion. The findings in the present study support the use of both ACE and WCE for testing peak oxygen uptake. However, WE differed between the two test modalities, meaning that less total energy is used to perform external work of 30 W during wheelchair exercise when using this WCE (VP100 Handisport ergometer. Clinical Trials Protocol Record is NCT00987155/4.2007.2271.

  17. Oxygen toxicity

    Directory of Open Access Journals (Sweden)

    C. A. van der Westhuizen

    1990-07-01

    Full Text Available Oxygen has been discovered about 200 years ago. Since then the vital physiological involvement of oxygen in various biologi­cal processes, mainly energy production, has been established. However, in the body molecular oxygen can be converted to toxic oxygen metabolites such as superoxide anion, hydrogen peroxide, the hydroxyl radical and singlet oxygen. These toxic metabolites are produced mainly in the mitochondria, plasma membranes and endoplasmic reticulum.

  18. Oxygen Consumption of Elite Distance Runners on an Anti-Gravity Treadmill®

    Directory of Open Access Journals (Sweden)

    David K.P. McNeill, John R. Kline, Hendrick D. de Heer, J. Richard Coast

    2015-06-01

    Full Text Available Lower body positive pressure (LBPP, or ‘anti-gravity’ treadmills® have become increasingly popular among elite distance runners. However, to date, few studies have assessed the effect of body weight support (BWS on the metabolic cost of running among elite runners. This study evaluated how BWS influenced the relationship between velocity and metabolic cost among 6 elite male distance runners. Participants ran three- 16 minute tests consisting of 4 stages of 4 minutes at 8, 7, 6 and 5 min·mile−1 pace (3.35, 3.84, 4.47 and 5.36 m·s−1, while maintaining an aerobic effort (Respiratory Exchange Ratio ≤1.00. One test was run on a regular treadmill, one on an anti-gravity treadmill with 40% BWS and one with 20% BWS being provided. Expired gas data were collected and regression equations used to determine and compare slopes. Significant decreases in oxygen uptake (V̇O2 were found with each increase in BWS (p < 0.001. At 20% BWS, the average decrease in net VO2 was greater than proportional (34%, while at 40% BWS, the average net reduction in VO2 was close to proportional (38%. Across velocities, the slope of the relationship between VO2 and velocity (ΔV̇O2/Δv was steeper with less support. The slopes at both the 20% and 40% BWS conditions were similar, especially when compared to the regular treadmill. Variability in VO2 between athletes was much greater on the LBPP treadmill and was greater with increased levels of BWS. In this study we evaluated the effect of body weight support on V̇O2 among elite distance runners. We have shown that oxygen uptake decreased with support, but not in direct proportion to that support. Further, because of the high variability in oxygen uptake between athletes on the LBPP treadmill, prediction equations may not be reliable and other indicators (heart rate, perceived exertion or directly measured oxygen uptake should be used to guide training intensity when training on the LBPP treadmill.

  19. Força muscular como determinante da eficiência do consumo de oxigênio e da máxima resposta metabólica ao exercício em pacientes com DPOC leve/moderada Muscle strength as a determinant of oxygen uptake efficiency and maximal metabolic response in patients with mild-to-moderate COPD

    Directory of Open Access Journals (Sweden)

    Paulo de Tarso Guerrero Müller

    2012-10-01

    Full Text Available OBJETIVO: Comparar o comportamento de oxygen uptake efficiency slope (OUES, inclinação da eficiência do consumo de oxigênio com o do consumo de oxigênio no pico do exercício (VO2pico. MÉTODOS: Estudo prospectivo transversal envolvendo 21 pacientes (15 homens com DPOC leve/moderada que foram submetidos a espirometria, dinamometria de preensão palmar (DIN, teste cardiopulmonar de exercício e medida de lactato no pico do exercício (LACpico. RESULTADOS: A média de peso foi 66,7 ± 13,6 kg, e a de idade foi 60,7 ± 7,8 anos. Com exceção de VEF1 e relação VEF1/CVF (75,8 ± 18,6 do previsto e 56,6 ± 8,8, respectivamente, as demais variáveis espirométricas foram normais, assim como DIN. As médias, em % do previsto, para VO2pico (93,1 ± 15,4, FC máxima (92,5 ± 10,4 e OUES (99,4 ± 24,4, assim como a da taxa de troca respiratória (1,2 ± 0,1, indicaram estresse metabólico e hemodinâmico importante. A correlação entre o VO2pico e a OUES foi elevada (r = 0,747; p OBJECTIVE: To compare the behavior of the oxygen uptake efficiency slope (OUES with that of oxygen uptake at peak exertion (VO2peak. METHODS: This was a prospective cross-sectional study involving 21 patients (15 men with mild-to-moderate COPD undergoing spirometry, handgrip strength (HGS testing, cardiopulmonary exercise testing, and determination of lactate at peak exertion (LACpeak. RESULTS: Mean weight was 66.7 ± 13.6 kg, and mean age was 60.7 ± 7.8 years. With the exception of FEV1 and FEV1/FVC ratio (75.8 ± 18.6 of predicted and 56.6 ± 8.8, respectively, all spirometric variables were normal, as was HGS. The patients exhibited significant metabolic and hemodynamic stress, as evidenced by the means (% of predicted for VO2peak (93.1 ± 15.4, maximum HR (92.5 ± 10.4, and OUES (99.4 ± 24.4, as well as for the gas exchange rate (1.2 ± 0.1. The correlation between VO2peak and OUES was significant (r = 0.747; p < 0.0001. The correlation between HGS and VO2peak (r

  20. [Oxidative power and intracellular distribution of mitochondria control cell oxygen regime when arterial hypoxemia occurs].

    Science.gov (United States)

    Liabakh, E G; Lissov, P N

    2012-01-01

    The regulatory impact of the mitochondria spatial distribution and enlargement in their oxidative power qO2 on the tissue oxygenation of skeletal muscle during hypoxia were studied. Investigations were performed by the mathematical modeling of 3D O2 diffusion-reaction in muscle fiber. The oxygen consumption rate VO2 and tissue pO2 were analyzed in response to a decrease in arterial blood oxygen concentration from 19.5 to 10 vol. % at a moderate load (3.5 ml/min per 100 g). The cells with evenly (case 1) and unevenly (case 2) distributed mitochondria were considered. According to calculations due to a rise in mitochondria oxidative power from 3.5 to 6.5 ml/min. per 100 g of tissue it is possible to maintain muscle oxygen V(O2) at constant level of 3.5 ml/min per 100 g despite a decrease in O2 delivery. Minimum value of tissue pO2 was about 0 and an area of hypoxia appeared inside the cell in case 1. But hypoxia disappeared and minimum value of pO2 increased from 0 to 4 mm Hg if mitochondria were distributed unevenly (case 2). It is shown that the possibilities of such regulation were limited and depended on the ratio of "the degree of hypoxemia--the level of oxygen delivery." It was assumed that an increase in mitochondria enzyme activity and mitochondria migration to the places of the greatest oxygen consumption rate can improve oxygen regime in the cells in terms of their adaptation to hypoxia. It is possible that changes in mitochondrial oxidative power and their intracellular redistribution may be considered as a new dimension in regulation of cell oxygen regime.

  1. Effect of Breakfast Omission on Energy Intake and Evening Exercise Performance.

    Science.gov (United States)

    Clayton, David J; Barutcu, Asya; Machin, Claire; Stensel, David J; James, Lewis J

    2015-12-01

    Breakfast omission may reduce daily energy intake. Exercising fasted impairs performance compared with exercising after breakfast, but the effect breakfast omission has on evening exercise performance is unknown. This study assessed the effect of omitting breakfast on evening exercise performance and within-day energy intake. Ten male, habitual breakfast eaters completed two trials in a randomized, counterbalanced order. Subjects arrived at the laboratory in an overnight-fasted state and either consumed or omitted a 733 ± 46 kcal (3095 ± 195 kJ) breakfast. Ad libitum energy intake was assessed at 4.5 h (lunch) and 11 h (dinner). At 9 h, subjects completed a 30-min cycling exercise at approximately 60% VO2peak, followed by a 30-min maximal cycling performance test. Food was not permitted for subjects once they left the laboratory after dinner until 0800 h the following morning. Acylated ghrelin, GLP-1(7-36), glucose, and insulin were assessed at 0, 4.5, and 9 h. Subjective appetite sensations were recorded throughout. Energy intake was 199 ± 151 kcal greater at lunch (P daily energy intake but may impair performance later that day, even after consuming lunch.

  2. Oxygen uptake in water polo, comparison and agreement in cycle ergometer and eggbeater kick: A pilot study

    Directory of Open Access Journals (Sweden)

    Ligia Ignêz Engelmann

    Full Text Available Abstract The aim of this study was to compare and verify the agreement of maximal oxygen uptake (VO2 max values obtained from tests on land and in water. Twelve recreational water polo players (30.5 ± 7.7 years; 79.2 ± 7.2 kg body mass; 179.1 ± 5.9 cm height were assessed in two phases: (1 in laboratory with maximal test on a cycle ergometer and (2 in a swimming pool with maximal test in eggbeater kick. Maximum values obtained in the two tests (respectively, cycle ergometer, and eggbeater kick: VO2 max = 40.2 ± 2.7 ml.kg-1.min-1 and 38.4 ± 5.7 ml.kg-1.min-1; RER = 1.17 ± 0.08 and 1.19 ± 0.12; HR max = 181.4 ± 11.7 bpm and 179 ± 11.7 bpm; IEP = 20 and 20 did not show significant differences. According to the Bland-Altman analyses, there were acceptable limits of agreement between the two tests (land and water. Therefore, it can be concluded that the eggbeater kick test is a specific and valid protocol to asses VO2 max in water polo players.

  3. Exertional oxygen uptake kinetics: a stamen of stamina?

    Science.gov (United States)

    Whipp, Brian J; Rossiter, H B; Ward, S A

    2002-04-01

    The fundamental pulmonary O(2) uptake (.VO(2)) response to moderate, constant-load exercise can be characterized as (d.VO(2)/dt)(tau)+Delta.VO(2) (t)=Delta.VO(2SS) where Delta.VO(2SS) is the steady-state response, and tau is the time constant, with the .VO(2) kinetics reflecting intramuscular O(2) uptake (.QO(2)) kinetics, to within 10%. The role of phosphocreatine (PCr) turnover in .QO(2) control can be explored using (31)P-MR spectroscopy, simultaneously with .VO(2). Although tau.VO(2) and tauPCr vary widely among subjects (approx. 20-65 s), they are not significantly different from each other, either at the on- or off-transient. A caveat to interpreting the "well-fit" exponential is that numerous units of similar Delta.VO(2SS) but with a wide tau distribution can also yield a .VO(2) response with an apparent single tau. This tau is, significantly, inversely correlated with lactate threshold and .VO(2max)(but is poorly predictive; a frail stamen, therefore), consistent with tau not characterizing a compartment with uniform kinetics. At higher intensities, the fundamental kinetics become supplemented with a slowly-developing phase, setting .VO(2)on a trajectory towards maximum .VO(2). This slow component is also demonstrable in Delta[PCr]: the decreased efficiency thereby reflecting a predominantly high phosphate-cost of force production rather than a high O(2)-cost of phosphate production. We also propose that the O(2)-deficit for the slow-component is more likely to reflect shifting Delta.VO(2SS) rather than a single one with a single tau.

  4. Developmental Effects Determine Submaximal Arterial Oxygen Saturation in Peruvian Quechua.

    Science.gov (United States)

    Kiyamu, Melisa; León-Velarde, Fabiola; Rivera-Chira, María; Elías, Gianpietro; Brutsaert, Tom D

    2015-06-01

    Kiyamu, Melisa, Fabiola León-Velarde, María Rivera-Chira, Gianpietro Elías, and Tom D. Brutsaert. Developmental effects determine submaximal arterial oxygen saturation in Peruvian Quechua. High Alt Med Biol 16, 138-146, 2015.--Andean high altitude natives show higher arterial oxygen saturation (Sao(2)) during exercise in hypoxia, compared to acclimatized sojourners. In order to evaluate the effects of life-long exposure to high altitude on Sao(2), we studied two groups of well-matched, self-identified Peruvian Quechua natives who differed in their developmental exposure to hypoxia before and after a 2-month training period. Male and female volunteers (18-35 years) were recruited in Lima, Peru (150 m). The two groups were: a) Individuals who were born and raised at sea-level (BSL, n=34) and b) Individuals who were born and raised at high altitude (BHA, n=32), but who migrated to sea-level as adults (>16 years old). Exercise testing was conducted using a submaximal exercise protocol in normobaric hypoxia in Lima (BP=750 mmHg, Fio(2)=0.12), in order to measure Sao(2) (%), ventilation (VE L/min) and oxygen consumption (Vo(2), L/min). Repeated-measures ANOVA, controlling for VE/VO(2) (L/min) and sex during the submaximal protocol showed that BHA maintained higher Sao(2) (%) compared to BSL at all workloads before (p=0.005) and after training (p=0.017). As expected, both groups showed a decrease in Sao(2) (%) (p<0.001), as workload increased. Resting Sao(2) levels were not found to be different between groups. The results suggest that developmental exposure to altitude contributes to the maintenance of higher Sao(2) levels during submaximal exercise at hypoxia.

  5. Biosensors for EVA: Muscle Oxygen and pH During Walking, Running and Simulated Reduced Gravity

    Science.gov (United States)

    Lee, S. M. C.; Ellerby, G.; Scott, P.; Stroud, L.; Norcross, J.; Pesholov, B.; Zou, F.; Gernhardt, M.; Soller, B.

    2009-01-01

    During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO2 on the leg during cycling. Our NSBRI-funded project is looking to extend this methodology to examine activities which more appropriately represent EVA activities, such as walking and running and to better understand factors that determine the metabolic cost of exercise in both normal and lunar gravity. Our 4 year project specifically addresses risk: ExMC 4.18: Lack of adequate biomedical monitoring capability for Constellation EVA Suits and EPSP risk: Risk of compromised EVA performance and crew health due to inadequate EVA suit systems.

  6. Effect of tin doping on oxygen- and carbon-related defects in Czochralski silicon

    International Nuclear Information System (INIS)

    Chroneos, A.; Londos, C. A.; Sgourou, E. N.

    2011-01-01

    Experimental and theoretical techniques are used to investigate the impact of tin doping on the formation and the thermal stability of oxygen- and carbon-related defects in electron-irradiated Czochralski silicon. The results verify previous reports that Sn doping reduces the formation of the VO defect and suppresses its conversion to the VO 2 defect. Within experimental accuracy, a small delay in the growth of the VO 2 defect is observed. Regarding carbon-related defects, it is determined that Sn doping leads to a reduction in the formation of the C i O i , C i C s , and C i O i (Si I ) defects although an increase in their thermal stability is observed. The impact of strain induced in the lattice by the larger tin substitutional atoms, as well as their association with intrinsic defects and carbon impurities, can be considered as an explanation to account for the above observations. The density functional theory calculations are used to study the interaction of tin with lattice vacancies and oxygen- and carbon-related clusters. Both experimental and theoretical results demonstrate that tin co-doping is an efficient defect engineering strategy to suppress detrimental effects because of the presence of oxygen- and carbon-related defect clusters in devices.

  7. Oxygen Therapy

    Science.gov (United States)

    ... their breathing to dangerously low levels. Will I need oxygen when I sleep? Usually if you use supplemental oxygen during the ... your health care provider tells you you only need to use oxygen for exercise or sleep. Even if you feel “fine” off of your ...

  8. The oxygen consumption rates of different life stages of the endoparasitic nematode

    Directory of Open Access Journals (Sweden)

    Willie van Aardt

    2010-01-01

    Full Text Available The oxygen consumption rates of different life stages of the endoparasitic nematode, Pratylenchus zeae (Nematoda: Tylenchida during non- and post-anhydrobiosisPratylenchus zeae, widely distributed in tropical and subtropical regions, is an endoparasite in roots of maize and other crop plants. The nematode is attracted to plant roots by CO2 and root exudates and feeds primarily on cells of the root cortex, making channels and openings where the eggs are deposited, with the result that secondary infection occurs due to bacteria and fungi. Nothing is known about the respiration physiology of this nematode and how it manages to survive during dry seasons. To measure the oxygen consumption rate (VO2 of individual P. zeae (less than half a millimeter long, a special measuring technique namely Cartesian diver micro-respirometry was applied. The Cartesian divers were machined from Perspex, and proved to be more accurate to measure VO2 compared with heavier glass divers used in similar experiments on free living nematodes. An accuracy of better than one nanoliter of oxygen consumed per hour was achieved with a single P. zeae inside the diver. Cartesian diver micro-respirometry measurements are based in principle on the manometric changes that occur in a fl otation tube in a manometer set-up when oxygen is consumed by P. zeae and CO2 from the animal is chemically absorbed. VO2 was measured for eggs (length: < 0.05 mm, larvae (length: 0.36 mm and adults (length: 0.47 mm before induction to anhydrobiosis. P. zeae from infected maize roots were extracted and exposed aseptically to in vitro maize root cultures in a grow cabinet at 50 % to 60% relative humidity at 28 ºC using eggs, larvae and adults. VO2 was also measured for post-anhydrobiotic eggs, larvae and adults by taking 50 individuals, eggs and larvae from the culture and placing them in Petri-dishes with 1% agar/water to dry out for 11 days at 28 ºC and 50% relative humidity. The VO2 was measured

  9. Oxygen consumption and heart rate responses to isolated ballet exercise sets.

    Science.gov (United States)

    Rodrigues-Krause, Josianne; Dos Santos Cunha, Giovani; Alberton, Cristine Lima; Follmer, Bruno; Krause, Mauricio; Reischak-Oliveira, Alvaro

    2014-01-01

    Ballet stage performances are associated with higher cardiorespiratory demand than rehearsals and classes. Hence, new interest is emerging to create periodized training that enhances dancers' fitness while minimizing delayed exercise-induced fatigue and possible injuries. Finding out in what zones of intensity dancers work during different ballet movements may support the use of supplemental training adjusted to the needs of the individual dancer. Therefore, the main purpose of this study was to describe dancers' oxygen consumption (VO2) and heart rate (HR) responses during the performance of nine isolated ballet exercise sets, as correlated with their first and second ventilatory thresholds (VT1 and VT2). Twelve female ballet dancers volunteered for the study. Their maximum oxygen consumption (VO2max), VT1, and VT2 were determined by use of an incremental treadmill test. Nine sets of ballet movements were assessed: pliés, tendus, jetés, rond de jambes, fondus, grand adage (adage), grand battements, temps levés, and sautés. The sets were randomly executed and separated by 5 minute rest periods. ANOVA for repeated measurements followed by the Bonferroni Post-hoc test were applied (p ballet sets. This stratification followed closely, but not exactly, the variation in HR. For example, rond de jambes (156.8 ± 19 b·min(-1)) did not show any significant difference from all the other ballet sets, nor VT1 or VT2. It is concluded that the workloads of isolated ballet sets, based on VO2 responses, vary between low and moderate aerobic intensity in relation to dancers' VT1 and VT2. However, ballet set workloads may be higher when based on HR responses, due to the intermittent and isometric components of dance.

  10. Maximal oxygen consumption, respiratory volume and some related factors in fire-fighting personnel

    Directory of Open Access Journals (Sweden)

    Touraj Khazraee

    2017-01-01

    Full Text Available Background: Firefighters for difficult activities and rescue of damaged people must be in appropriate physical ability. Maximal oxygen capacity is an indicator for diagnosis of physical ability of workers. This study aimed to assess the cardiorespiratory system and its related factors in firefighters. Methods: This study was conducted on 110 firefighters from various stations. An self-administered questionnaire (respiratory disorders questionnaire, Tuxworth-Shahnavaz step test, and pulmonary function test was used to collection of required data. Average of humidity and temperature was 52% and 17°C, respectively. Background average noise levels were between 55 and 65 dB. Data were analyzed using SPSS software (version 19. Results: The mean age of the study participants was 32 ± 6.2 years. The means of forced vital capacity (FVC, forced expiratory volume in 1 s (FEV1, and FEV1/FVC were 92% ±9.4%, 87% ±9.2%, and 80% ±6.1%, respectively. The participants' mean VO2-max was 2.79 ± 0.29 L/min or 37.34 ± 4.27 ml/kg body weight per minute. The results revealed that weight has a direct association with vital capacity (VC, FVC, and peak expiratory flow. In addition, height was directly associated with VC, FVC, and VO2-max (P < 0.05. However, there was an inverse and significant association between height and FEV1/FVC (r = −0.23,P< 0.05. Height, weight, body mass index, and waist circumference were directly associated with VO2-max. Conclusions: The findings of this study showed that the amount of maximum oxygen consumption is close with the proposed range of this parameter among firefighters in other studies. Furthermore, the results of the study revealed that individuals had normal amounts of lung volume index. This issue can be attributed to the appropriate usage of respiratory masks.

  11. A fast-start pacing strategy speeds pulmonary oxygen uptake kinetics and improves supramaximal running performance.

    Directory of Open Access Journals (Sweden)

    Tiago Turnes

    Full Text Available The focus of the present study was to investigate the effects of a fast-start pacing strategy on running performance and pulmonary oxygen uptake (VO2 kinetics at the upper boundary of the severe-intensity domain. Eleven active male participants (28±10 years, 70±5 kg, 176±6 cm, 57±4 mL/kg/min visited the laboratory for a series of tests that were performed until exhaustion: 1 an incremental test; 2 three laboratory test sessions performed at 95, 100 and 110% of the maximal aerobic speed; 3 two to four constant speed tests for the determination of the highest constant speed (HS that still allowed achieving maximal oxygen uptake; and 4 an exercise based on the HS using a higher initial speed followed by a subsequent decrease. To predict equalized performance values for the constant pace, the relationship between time and distance/speed through log-log modelling was used. When a fast-start was utilized, subjects were able to cover a greater distance in a performance of similar duration in comparison with a constant-pace performance (constant pace: 670 m±22%; fast-start: 683 m±22%; P = 0.029; subjects also demonstrated a higher exercise tolerance at a similar average speed when compared with constant-pace performance (constant pace: 114 s±30%; fast-start: 125 s±26%; P = 0.037. Moreover, the mean VO2 response time was reduced after a fast start (constant pace: 22.2 s±28%; fast-start: 19.3 s±29%; P = 0.025. In conclusion, middle-distance running performances with a duration of 2-3 min are improved and VO2 response time is faster when a fast-start is adopted.

  12. Seasonal variations in body composition, maximal oxygen uptake, and gas exchange threshold in cross-country skiers.

    Science.gov (United States)

    Polat, Metin; Korkmaz Eryılmaz, Selcen; Aydoğan, Sami

    2018-01-01

    In order to ensure that athletes achieve their highest performance levels during competitive seasons, monitoring their long-term performance data is crucial for understanding the impact of ongoing training programs and evaluating training strategies. The present study was thus designed to investigate the variations in body composition, maximal oxygen uptake (VO 2max ), and gas exchange threshold values of cross-country skiers across training phases throughout a season. In total, 15 athletes who participate in international cross-country ski competitions voluntarily took part in this study. The athletes underwent incremental treadmill running tests at 3 different time points over a period of 1 year. The first measurements were obtained in July, during the first preparation period; the second measurements were obtained in October, during the second preparation period; and the third measurements were obtained in February, during the competition period. Body weight, body mass index (BMI), body fat (%), as well as VO 2max values and gas exchange threshold, measured using V-slope method during the incremental running tests, were assessed at all 3 time points. The collected data were analyzed using SPSS 20 package software. Significant differences between the measurements were assessed using Friedman's twoway variance analysis with a post hoc option. The athletes' body weights and BMI measurements at the third point were significantly lower compared with the results of the second measurement ( p exchange threshold, running speed at the gas exchange threshold, VO 2max , amount of oxygen consumed at gas exchange threshold level (VO 2GET ), maximal heart rate (HR max ), and heart rate at gas exchange threshold level (HR GET ) values did not significantly differ between the measurement time points ( p >0.05). VO 2max and gas exchange threshold values recorded during the third measurements, the timing of which coincided with the competitive season of the cross-country skiers

  13. Oxygen Therapy

    Directory of Open Access Journals (Sweden)

    Bonnie Solmes

    2000-01-01

    Full Text Available LTOT is prescribed for people with chronic lung disease in whom there is a decrease in the ability of the lungs to supply enough oxygen to the body. The heart is obliged to pump faster to meet the body's oxygen requirements. This may place undue stress on the heart, resulting in palpitations, dizziness and fatigue. A low oxygen level in arterial blood is also harmful to the heart, the brain and the pulmonary blood vessels. Oxygen therapy is used to break this cycle. A person with low blood oxygen will often be able to accomplish more with less fatigue with the help of supplemental oxygen therapy. Shortness of breath is a mechanical problem resulting from the effects of chronic obstructive pulmonary disease. Oxygen therapy may or may not reduce shortness of breath, but it will help the lungs and heart to function with less stress.

  14. The effect of salinity on resting metabolism in Eurasian perch (Perca fluviathlis L.)

    DEFF Research Database (Denmark)

    Ern, R.; Cong, N.; Houng, D.

    2008-01-01

    to properly maintain ion balance even with minor increases in the environmental salinity. The elevated resting VO2 in 10 ppt is equivalent to an increased energy consumption of 975 extra calories per day, and since food intake was unaffected, it is reasonable to assume that the reduced growth seen...... in a freshwater population of P. fluviatilis. Food intake was unaffected and we, therefore, measured resting oxygen uptake (VO2) in fish maintained for 21 days in either fresh or brackish (10 ppt) water using intermittent closed respirometry. VO2 of all fish reached stable levels within 5 h of entering...

  15. Structure and catalytic properties of metal β-diketonate complexes with oxygen-containing compounds

    International Nuclear Information System (INIS)

    Nizel'skij, Yu.N.; Ishchenko, S.S.; Lipatova, T.Eh.

    1985-01-01

    The results of researches published in recent 15-20 years of complexes of metal β-diketonates (including Cr 3+ , VO 2+ , MoOΛ2 2+ , Co 3+ , Mn 3+ , Ni 2+ , Fe 3+ ) with oxygen-containing compounds (alcohols, glycols, phenols, hydroperoxides, aldehydes, esters, etc.) playing an important role in catalytic processes of oxidation, addition, polymerization and copolymerization are reviewed. Data on the nature of chemical bond of oxygen-containing reacting agents with metal β-diketonates, on structure of metal β-diketonate complexes with oxygen-containing reacting agents and thermodynamics of complexing as well as on activation of reacting agents in complexes and catalytic properties of metal β-diketonates are discussed. Stored materials make it possible to exercise directed control of metal β-diketonate activity

  16. Appetite, food intake and gut hormone responses to intense aerobic exercise of different duration.

    Science.gov (United States)

    Holliday, Adrian; Blannin, Andrew

    2017-12-01

    The purpose of the study is to investigate the effect of acute bouts of high-intensity aerobic exercise of differing durations on subjective appetite, food intake and appetite-associated hormones in endurance-trained males. Twelve endurance-trained males (age = 21 ± 2 years; BMI = 21.0 ± 1.6 kg/m 2 ; VO 2max  = 61.6 ± 6.0 mL/kg/min) completed four trials, within a maximum 28 day period, in a counterbalanced order: resting (REST); 15 min exercise bout (15-min); 30 min exercise bout (30-min) and 45 min exercise bout (45-min). All exercise was completed on a cycle ergometer at an intensity of ~76% VO 2max Sixty minutes post exercise, participants consumed an ad libitum meal. Measures of subjective appetite and blood samples were obtained throughout the morning, with plasma analyzed for acylated ghrelin, total polypeptide tyrosine-tyrosine (PYY) and total glucagon-like peptide 1 (GLP-1) concentrations. The following results were obtained: Neither subjective appetite nor absolute food intake differed between trials. Relative energy intake (intake - expenditure) was significantly greater after REST (2641 ± 1616 kJ) compared with both 30-min (1039 ± 1520 kJ) and 45-min (260 ± 1731 kJ), and significantly greater after 15-min (2699 ± 1239 kJ) compared with 45-min (condition main effect, P  exercise in 30-min and 45-min, respectively (condition × time interaction, P  exercise trials (condition × time interaction, P  = 0.011); the greatest, most enduring suppression, was observed in 45-min. PYY concentration was unchanged with exercise. In conclusion, high-intensity aerobic cycling lasting up to 45 min did not suppress subjective appetite or affect absolute food intake, but did reduce relative energy intake, in well-trained endurance athletes. Findings question the role of appetite hormones in regulating subjective appetite in the acute post-exercise period. © 2017 Society for Endocrinology.

  17. Agricultural Drainage Well Intakes

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Locations of surface intakes for registered agriculture drainage wells according to the database maintained by IDALS. Surface intakes were located from their...

  18. Oxygen diffusion coefficient in isolated chicken red and white skeletal muscle fibers in ontogenesis.

    Science.gov (United States)

    Baranov, V I; Belichenko, V M; Shoshenko, C A

    2000-09-01

    Oxygen diffusion from medium to cultured isolated muscle fibers from red gastrocnemius muscle (deep part) (RGM) and white pectoralis muscle (WPM) of embryonic and postnatal chickens (about 6 months) was explored. The intracellular effective O(2) diffusion coefficient (D(i)) in muscle fiber was calculated from a model of a cylindrical fiber with a uniform distribution of an oxygen sink based on these experimentally measured parameters: critical tension of O(2) (PO(2)) on the surface of a fiber, specific rate of O(2) consumption by a weight unit of muscle fibers (;VO(2)), and average diameter of muscle fibers. The results document the rapid hypertrophic growth of RGM fibers when compared to WPM fibers in the second half of the embryonic period and the higher values of;VO(2) and critical PO(2) during the ontogenetic period under study. The oxygen D(i) in RGM fibers of embryos and 1-day chickens was two to three times higher than observed for WPM fibers. For senior chickens, the oxygen D(i) value in RGM and WPM fibers does not differ. The D(i) of O(2) in both RGM and WPM fibers increased from 1.4-2.7 x 10(-8) to 90-95 x 10(-8) cm(2)/s with an ontogenetic increase in fiber diameter from 7. 5 to 67.0 microm. At all stages the oxygen D(i) values in RGM and WPM fibers are significantly lower than the O(2) diffusion coefficient in water: for 11-day embryos they are 889 and 1714 times lower and for adult individuals 25 and 27 times lower, respectively. Why oxygen D(i) values in RGM and WPM fibers are so low and why they are gradually increasing during the course of hypertrophic ontogenetic growth are still unclear. Copyright 2000 Academic Press.

  19. Comparação entre diferentes métodos de análise do componente lento do consumo de oxigênio: uma abordagem no domínio muito intenso de exercício Comparison between different methods of analysis of slow component of oxygen uptake: a view in severe exercise domain

    Directory of Open Access Journals (Sweden)

    Marcos G. Santana

    2007-08-01

    Full Text Available O objetivo do presente estudo foi comparar, em domínio muito intenso de exercício, diferentes técnicas utilizadas para medir a amplitude do componente lento (CL da cinética do consumo de oxigênio. Dez ciclistas treinados, do gênero masculino [média ± DP (idade: 25 ± 3,6 anos, massa corporal: 67,2 ± 4,5kg, altura: 174,8 ± 6,5cm e VO2max: 62,4 ± 3,1ml.kg¹.min¹], realizaram duas idênticas transições de carga constante (intensidade de 75%delta: 75% da diferença entre o VO2 no limiar de lactato e o VO2max em dias diferentes. O CL foi calculado a partir de diferentes métodos: (1 modelo biexponencial [VO2(t = VO2base + A1 (1 e-(t-TA1/t1 + A2 (1 e(tTA2/t2], (2 intervalos predeterminados (o deltaVO26-2: diferença do VO2 entre o segundo e o sexto minuto de exercício e o deltaVO263: diferença do VO2 entre o terceiro e o sexto minuto de exercício e (3 diferença entre o VO2 obtido no final do exercício e o valor obtido a partir de um ajuste monoexponencial do "componente primário" (tempo predeterminado de 120s (CL6"CP". Todos os métodos foram comparados entre si. Os resultados demonstraram significante subestimação do CL obtido pelo método de intervalos predeterminados (deltaVO26-2: 432 ± 126ml.min¹ e deltaVO263: 279 ± 88ml.min¹ quando comparado com o modelo biexponencial (676 ± 136ml.min¹ e ao CL6"CP" [(719 ± 265ml.min¹ (p The objective of the present study was to compare in severe exercise domain, different techniques used for measuring the amplitude of the slow component (SC of oxygen uptake kinetics. Ten trained cyclists, male (age: 25 ± 3.6 years, body mass: 67.2 ± 4.5 kg, height: 174.8 ± 6.5 cm and VO2max: 62.4 ± 3.1 mL.kg¹.min¹, performed two identical bouts transitions at constant load [mean ± SD (intensity 75%delta: 75% of the difference between the VO2 lactate threshold and the VO2max] in different days. The SC was calculated from different methods: (1 bi-exponential model [VO2(t = VO2base + A1 (1 e(tTA1

  20. High-dose inhaled salbutamol has no acute effects on aerobic capacity or oxygen uptake kinetics in healthy trained men

    DEFF Research Database (Denmark)

    Elers, J; Mørkeberg, Jakob; Jansen, T

    2012-01-01

    enrolled nine healthy well-trained men in a randomized, blinded, placebo-controlled crossover study. Subjects were randomized to inhalation of 40 puffs of 0.2 mg salbutamol or two placebo tablets and performed an incremental test to exhaustion and three submaximal tests at 75% of peak power to determine...... oxygen uptake kinetics. During the incremental test, there were no effects of inhaled salbutamol on VO(2max) in absolute or relative terms, and no effect on peak power and lactate threshold. During the submaximal test, we found no effects on the time constant, time delay, the mean response time or O(2...

  1. Changes in cardiac activity, oxygen uptake and perfusion indices in Carcinus maenas (L. ) exposed to crude oil and dispersant

    Energy Technology Data Exchange (ETDEWEB)

    Depledge, M.H.

    1984-01-01

    Cardiac activity and oxygen consumption increased when C. maenas were exposed to a 20% solution of the water-soluble fraction of Fortes crude oil, a 10% solution of the dispersant BP1100WD or a combination of both. Normal feeding behaviour was disrupted. Perfusion indices (Q/VO2) decreased as locomotor activity increased following exposure to crude oil. However, exposure to dispersant or dispersant + crude oil resulted in elevation of perfusion index despite crabs becoming active. All test animals survived for at least 6 weeks following exposure to the pollutants. The acute, sublethal effects of dispersant and dispersant + crude oil were more severe than the effects of crude oil alone.

  2. Effect of Aerobic Training on Peak Oxygen Uptake Among Seniors Aged 70 or Older: A Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Bouaziz, Walid; Kanagaratnam, Lukshe; Vogel, Thomas; Schmitt, Elise; Dramé, Moustapha; Kaltenbach, Georges; Geny, Bernard; Lang, Pierre Olivier

    2018-01-02

    Older adults undergo a progressive decline in cardiorespiratory fitness and functional capacity. This lower peak oxygen uptake (VO 2peak ) level is associated with increased risk of frailty, dependency, loss of autonomy, and mortality from all causes. Regular physical activity and particularly aerobic training (AT) have been shown to contribute to better and healthy aging. We conducted a meta-analysis to measure the exact benefit of AT on VO 2peak in seniors aged 70 years or older. A comprehensive, systematic database search for articles was performed in Embase, Medline, PubMed Central, Science Direct, Scopus, and Web of Science using key words. Two reviewers independently assessed interventional studies for potential inclusion. Ten randomized controlled trials (RCTs) were included totaling 348 seniors aged 70 years or older. Across the trials, no high risk of bias was measured and all considered open-label arms for controls. With significant heterogeneity between the RCTs (all p seniors were, respectively, 1.72 (95% CI: 0.34-3.10) and 1.47 (95% CI: 0.60-2.34). This meta-analysis confirms the AT-associated benefits on VO 2peak in healthy and unhealthy seniors.

  3. A comparison of normal versus low dietary carbohydrate intake on substrate oxidation during and after moderate intensity exercise in women.

    Science.gov (United States)

    Patterson, Rachel; Potteiger, Jeffrey A

    2011-12-01

    We compared the effects of consuming a 2-day low-carbohydrate (CHO) diet (low-CHO; 20% CHO, 40% protein, 40% fat) versus an isocaloric 2-day moderate-CHO diet (mod-CHO; 55% CHO, 15% protein, 30% fat) on substrate oxidation during and after exercise in ten active, young women. Subjects were 24.9 ± 6.2% body fat with a VO(2max) of 68.8 ± 13.8 ml/kg FFM/min. For 2 days prior to exercise, subjects consumed either the mod-CHO or the low-CHO diet and then completed treadmill exercise at 55% of VO(2max) until 350 kcal of energy was expended. During exercise and for 2 h post-exercise, expired gases were analyzed to determine oxidation rates for CHO (CHO-OX) and fat (FAT-OX). Significant differences (p FAT-OX (mg/kg FFM/min) during exercise, 1 h post-ex, and 2 h post-ex. During exercise, FAT-OX was higher (low-CHO 8.7 ± 2.2 vs. mod-CHO 6.2 ± 2.2) and CHO-OX was lower (low-CHO 25.1 ± 5.6 vs. mod-CHO 31.1 ± 6.2) following the low-CHO diet. A similar trend was observed during 1 h post-ex for FAT-OX (low-CHO 2.2 ± 0.5 vs. mod-CHO 1.6 ± 0.5) and CHO-OX (low-CHO 2.5 ± 1.2 vs. mod-CHO 4.1 ± 1.9), as well as 2 h post-ex for FAT-OX (low-CHO vs. 1.9 ± 0.5 mod-CHO 1.7 ± 0.4) and CHO-OX (low-CHO 2.5 ± 0.9 vs. mod-CHO 3.1 ± 1.1). Significant positive correlations were observed between VO(2max) and CHO-OX during exercise and post-exercise, as well as significant negative correlations between VO(2max) and FAT-OX post-exercise in the low-CHO condition. Waist circumference and FAT-OX exhibited a significant negative correlation during exercise in the low-CHO condition. Dietary macronutrient intake influenced substrate oxidation in active young women during and after moderate intensity exercise.

  4. Application of the allometric scale for the submaximal oxygen uptake in runners and rowers

    Directory of Open Access Journals (Sweden)

    M.P. Tartaruga

    2010-12-01

    Full Text Available Background: The aim of the current study was to determine the allometric exponents for runners and rower’s metabolic cost, while also verifying the relation of performance with and without the allometric application. Methods: Eleven runners (age: 22.3±10.4 years; height: 174±8.8 cm; body mass: 61.7±9.3 kg; maximum oxygen uptake ( •VO2max: 56.3±3.9 ml.kg[sup]-1[/sup].min[sup]-1[/sup] and fifteen rowers (age: 24±5.4 years; height: 185.5±6.5 cm; body mass: 83.5±7.2 kg; •VO2max: 61.2±3.4 ml.kg[sup]-1[/sup].min[sup]-1[/sup] carried out a specific progressive maximum test. The allometric exponent was determined from the logarithmic equation Log y = Log b Log x, where x is the mass, y is the VO2max (l.min[sup]-1[/sup], a is one constant and b is the allometric exponent. The data were analyzed using descriptive and comparative statistics (independent T test of the Student, with p<0.05 (SPSS version 13.0. Results: The allometric exponent of the rowers was 0.70 and that of the runners was 1.00. Significant differences were found between the fat mass percentage, with higher value for rowers, suggesting that this variable may influence the behavior of the allometric exponent and consequently of the basal metabolic rate. Conclusions: Scaling may help in understanding variation in aerobic power and in defining the physiological limitations of work capacity.

  5. Pre- and post-season dietary intake, body composition, and performance indices of NCAA division I female soccer players.

    Science.gov (United States)

    Clark, Mandy; Reed, Debra B; Crouse, Stephen F; Armstrong, Robert B

    2003-09-01

    Little published data describe the dietary and physiological profiles of intercollegiate female soccer players; therefore, the purpose of this investigation was to report baseline dietary data, anthropometrics, and performance indices of soccer women during rigorous pre-season training (2 sessions/day) and then during the post-competitive season. Members of a NCAA Division I women's soccer squad completed 3-day diet records, anthropometrics, and physical tests, including VO2peak. Average body mass was 62 kg with 16% body fat, and no significant pre to post differences were observed. Total energy, carbohydrate (CHO), protein, and fat intakes were significantly greater during the pre-season. Pre-season energy intake met the DRI for females with an "active" lifestyle (37 kcal/kg). While CHO intake failed to meet minimum recommendations to promote glycogen repletion (7-10 g/kg), protein and fat intakes were above minimum recommendations. Pre- and post-season intakes of several micronutrients were marginal (failed to meet minimum CHO and micronutrient recommendations. Foods higher in protein and fat displaced more CHO-rich and nutrient-dense foods within athletes' energy requirements and satiety limits.

  6. The effects of altitude/hypoxic training on oxygen delivery capacity of the blood and aerobic exercise capacity in elite athletes - a meta-analysis.

    Science.gov (United States)

    Park, Hun-Young; Hwang, Hyejung; Park, Jonghoon; Lee, Seongno; Lim, Kiwon

    2016-03-31

    This study was designed as a meta-analysis of randomized controlled trials comparing effectiveness of altitude/hypoxic training (experimental) versus sea-level training (control) on oxygen delivery capacity of the blood and aerobic exercise capacity of elite athletes in Korea. Databases (Research Information Service System, Korean studies Information Service System, National Assembly Library) were for randomized controlled trials comparing altitude/hypoxic training versus sea-level training in elite athletes. Studies published in Korea up to December 2015 were eligible for inclusion. Oxygen delivery capacity of the blood was quantified by red blood cell (RBC), hemoglobin (Hb), hematocrit (Hct), erythropoietin (EPO); and aerobic exercise capacity was quantified by maximal oxygen consumption (VO2max). RBC, Hb, Hct, VO2max represented heterogeneity and compared post-intervention between altitude/hypoxic training and sea-level training in elite athletes by a random effect model meta-analysis. EPO represented homogeneity and meta-analysis performed by a fixed effect model. Eight independent studies with 156 elite athletes (experimental: n = 82, control: n = 74) were included in the metaanalysis. RBC (4.499×10(5) cell/ul, 95 % CI: 2.469 to 6.529), Hb (5.447 g/dl, 95 % CI: 3.028 to 7.866), Hct (3.639 %, 95 % CI: 1.687 to 5.591), EPO (0.711 mU/mL, 95% CI: 0.282 to 1.140), VO2max (1.637 ml/kg/min, 95% CI: 0.599 to 1.400) showed significantly greater increase following altitude/hypoxic training, as compared with sea-level training. For elite athletes in Korea, altitude/ hypoxic training appears more effective than sea-level training for improvement of oxygen delivery capacity of the blood and aerobic exercise capacity.

  7. The effects of altitude/hypoxic training on oxygen delivery capacity of the blood and aerobic exercise capacity in elite athletes – a meta-analysis

    Science.gov (United States)

    Park, Hun-young; Hwang, Hyejung; Park, Jonghoon; Lee, Seongno; Lim, Kiwon

    2016-01-01

    [Purpose] This study was designed as a meta-analysis of randomized controlled trials comparing effectiveness of altitude/hypoxic training (experimental) versus sea-level training (control) on oxygen delivery capacity of the blood and aerobic exercise capacity of elite athletes in Korea. [Methods] Databases (Research Information Service System, Korean studies Information Service System, National Assembly Library) were for randomized controlled trials comparing altitude/hypoxic training versus sea-level training in elite athletes. Studies published in Korea up to December 2015 were eligible for inclusion. Oxygen delivery capacity of the blood was quantified by red blood cell (RBC), hemoglobin (Hb), hematocrit (Hct), erythropoietin (EPO); and aerobic exercise capacity was quantified by maximal oxygen consumption (VO2max). RBC, Hb, Hct, VO2max represented heterogeneity and compared post-intervention between altitude/hypoxic training and sea-level training in elite athletes by a random effect model meta-analysis. EPO represented homogeneity and meta-analysis performed by a fixed effect model. Eight independent studies with 156 elite athletes (experimental: n = 82, control: n = 74) were included in the metaanalysis. [Results] RBC (4.499×105 cell/ul, 95 % CI: 2.469 to 6.529), Hb (5.447 g/dl, 95 % CI: 3.028 to 7.866), Hct (3.639 %, 95 % CI: 1.687 to 5.591), EPO (0.711 mU/mL, 95% CI: 0.282 to 1.140), VO2max (1.637 ml/kg/min, 95% CI: 0.599 to 1.400) showed significantly greater increase following altitude/hypoxic training, as compared with sea-level training. [Conclusion] For elite athletes in Korea, altitude/ hypoxic training appears more effective than sea-level training for improvement of oxygen delivery capacity of the blood and aerobic exercise capacity. PMID:27298808

  8. The relationship between body temperature, heart rate, breathing rate, and rate of oxygen consumption, in the tegu lizard (Tupinambis merianae) at various levels of activity.

    Science.gov (United States)

    Piercy, Joanna; Rogers, Kip; Reichert, Michelle; Andrade, Denis V; Abe, Augusto S; Tattersall, Glenn J; Milsom, William K

    2015-12-01

    The present study determined whether EEG and/or EMG recordings could be used to reliably define activity states in the Brazilian black and white tegu lizard (Tupinambis merianae) and then examined the interactive effects of temperature and activity states on strategies for matching O2 supply and demand. In a first series of experiments, the rate of oxygen consumption (VO2), breathing frequency (fR), heart rate (fH), and EEG and EMG (neck muscle) activity were measured in different sleep/wake states (sleeping, awake but quiet, alert, or moving). In general, metabolic and cardio-respiratory changes were better indictors of the transition from sleep to wake than were changes in the EEG and EMG. In a second series of experiments, the interactive effects of temperature (17, 27 and 37 °C) and activity states on fR, tidal volume (VT), the fraction of oxygen extracted from the lung per breath (FIO2-FEO2), fH, and the cardiac O2 pulse were quantified to determine the relative roles of each of these variables in accommodating changes in VO2. The increases in oxygen supply to meet temperature- and activity-induced increases in oxygen demand were produced almost exclusively by increases in fH and fR. Regression analysis showed that the effects of temperature and activity state on the relationships between fH, fR and VO2 was to extend a common relationship along a single curve, rather than separate relationships for each metabolic state. For these lizards, the predictive powers of fR and fH were maximized when the effects of changes in temperature, digestive state and activity were pooled. However, the best r(2) values obtained were 0.63 and 0.74 using fR and fH as predictors of metabolic rate, respectively.

  9. Critical oxygen tension and the effect of hypoxia on the oxygen consumption of the striped catfish, Pangasius hypophthaimos (Pangasiidae)

    DEFF Research Database (Denmark)

    Lefevre, S.; Bayley, Mark; Wang, Tobias

    2008-01-01

    The striped catfish (Pangasius hypophthalmus) is an air-breathing teleost that uses a modified swim bladder for aerial gas exchange. Pangasius is of enormous importance for aquaculture industry in the Mekong Delta(Vietnam), but little is known about its physiology. We have initiated a series...... consumption (VO2), measured with intermittent closed respirometry, was 67.8 ± 5.1 mLO2/kg/h when the fish were maintained without access to air at 27 °C. The critical oxygen tension (Pcrit) at these conditions was 57.9 ± 8.9 mmHg (N = 7). The metabolic response to aquatic hypoxia was studied in fish subjected....... The ontogenetic effect of environmental PO2 on metabolism is currently under investigation with fish being reared in 30%, 60% and 100% saturation. Data on resting VO2and Pcrit will be presented and discussed for these animals....

  10. Efeitos agudos de diferentes intensidades de exercício sobre a ingestão alimentar pós-exercício Acute effects of exercise intensity on pos-exercise food intake in young men

    Directory of Open Access Journals (Sweden)

    Tatiana Acioli Lins

    2011-06-01

    Full Text Available O objetivo do presente estudo foi verificar os efeitos agudos de diferentes intensidades de exercício aerróbio (40 e 80% do VO2pico sobre a ingestão alimentar pós-exercício. Participaram do estudo 18 adultos jovens, eutróficos (22,20 ± 1,72 kg/m² e fisicamente ativos. Todos os sujeitos foram submetidos aleatoriamente a três condições experimentais: controle (sem exercício; EBI, exercício de baixa intensidade (40% doVO2pico e EAI, exercício de alta intensidade (80% do VO2pico. As sessões de exercício foram isocalróricas (350 kcal. Após 120 minutos de recuperação passiva, os voluntários tinham livre acesso a um "buffet" variado de alimentos, a ingestão alimentar foi determinada atravéz da pesagem dos alimentos ingeridos. Os dados alimentares obtidos foram então tabulados e analisados por meio do "software" Nutwin 6.0 (UNIFESP, 2002, para estimativa do consumo energético total (kcal e ingestão dos macronutrientes (carboidratos, proteínas e lipídeos em gramas. Os resultados não demonstram nenhuma diferença na ingesto alimentar entre as condições experimentais analisadas. Dessa forma, podemos concluir que a ingestão alimentar pós-exercício não se mostrou dependente da intensidade do esforóo em curto prazo em indivíduos adultos jovens fisicamente ativos.The aim of this study was to investigate the acute effects of different aerobic exercise intensities (40 and 80% do VO2peak on post-exercise food intake. The sample was composed of eighteen healthy, physically active young men, of normal weight (22.20 ± 1.72 kg/m². Subjects were randomly submitted to three experimental conditions: control (no exercise; low-intensity exercise (LIE -40% of VO2peak and high-intensity exercise (HIE- 80% of VO2peak. Exercise trials were iso-caloric (350 Kcal. After 120 minutes of passive recovery, the volunteers had free access to a variety food buffet, and food intake was determined thru food weight. Data was analyzed by the software

  11. [The effect of prophylactically administered n-acetylcysteine on clinical indicators for tissue oxygenation during hyperoxic ventilation in cardiac risk patients].

    Science.gov (United States)

    Spies, C; Giese, C; Meier-Hellmann, A; Specht, M; Hannemann, L; Schaffartzik, W; Reinhart, K

    1996-04-01

    Hyperoxic ventilation, used to prevent hypoxia during potential periods of hypoventilation, has been reported to paradoxically decrease whole-body oxygen consumption (VO2). Reduction in nutritive blood flow due to oxygen radical production is one possible mechanism. We investigated whether pretreatment with the sulfhydryl group donor and O2 radical scavenger N-acetylcysteine (NAC) would preserve VO2 and other clinical indicators of tissue oxygenation in cardiac risk patients. Thirty patients, requiring hemodynamic monitoring (radial and pulmonary artery catheters) because of cardiac risk factors, were included in this randomized investigation. All patients exhibited stable clinical conditions (hemodynamics, body temperature, hemoglobin, F1O2 depression ( > 0.2 mV) was significantly less marked in the NAC group (NAC: -0.02 +/- 0.17 vs placebo: -0.23 +/- 0.15; P depression if patients were prophylactically treated with NAC. This suggests that pretreatment with NAC could be considered to attenuate impaired tissue oxygenation and to preserve myocardial performance better in cardiac risk patients during hyperoxia.

  12. Influence of oxygen uptake kinetics on physical performance in youth soccer.

    Science.gov (United States)

    Doncaster, Greg; Marwood, Simon; Iga, John; Unnithan, Viswanath

    2016-09-01

    To examine the relationship between oxygen uptake kinetics (VO2 kinetics) and physical measures associated with soccer match play, within a group of highly trained youth soccer players. Seventeen highly trained youth soccer players (age: 13.3 ± 0.4 year, self-assessed Tanner stage: 3 ± 1) volunteered for the study. Players initially completed an incremental treadmill protocol to exhaustion, to establish gaseous exchange threshold (GET) and VO2max (59.1 ± 5.4 mL kg(-1) min(-1)). On subsequent visits, players completed a step transition protocol from rest-moderate-intensity exercise, followed by an immediate transition, and from moderate- to severe-intensity exercise (moderate: 95 % GET, severe: 60 %∆), during which VO2 kinetics were determined. Physical soccer-based performance was assessed using a maximal Yo-Yo intermittent recovery test level 1 (Yo-Yo IR1) and via GPS-derived measures of physical soccer performance during soccer match play, three 2 × 20 min, 11 v 11 matches, to gain measures of physical performance during soccer match play. Partial correlations revealed significant inverse relationships between the unloaded-to-moderate transition time constant (tau) and: Yo-Yo IR1 performance (r = -0.58, P = 0.02) and GPS variables [total distance (TD): r = -0.64, P = 0.007, high-speed running (HSR): r = -0.64, P = 0.008 and high-speed running efforts (HSReff): r = -0.66, P = 0.005]. Measures of VO2 kinetics are related to physical measures associated with soccer match play and could potentially be used to distinguish between those of superior physical performance, within a group of highly trained youth soccer players.

  13. Exercise and diet enhance fat oxidation and reduce insulin resistance in older obese adults

    DEFF Research Database (Denmark)

    Solomon, Thomas; Sistrun, Sakita N; Krishnan, Raj K

    2008-01-01

    oxygen consumption (Vo(2max))] with either normal caloric intake (eucaloric group, 1,901 +/- 277 kcal/day, n = 12) or a reduced-calorie diet (hypocaloric group, 1,307 +/- 70 kcal/day, n = 11), as dictated by nutritional counseling. Body composition (decreased fat mass; maintained fat-free mass), aerobic...... fitness (Vo(2max)), leptinemia, insulin sensitivity, and intramyocellular lipid accumulation (IMCL) in skeletal muscle improved in both groups (P hypocaloric group. Following the intervention...

  14. Dietary intake of phytoestrogens

    NARCIS (Netherlands)

    Bakker MI; SIR

    2004-01-01

    The dietary intake of phytoestrogens supposedly influences a variety of diseases, both in terms of beneficial and adverse effects. This report describes current knowledge on dietary intakes of phytoestrogens in Western countries, and briefly summarizes the evidence for health effects. The

  15. Long-term fasting decreases mitochondrial avian UCP-mediated oxygen consumption in hypometabolic king penguins.

    Science.gov (United States)

    Rey, Benjamin; Halsey, Lewis G; Dolmazon, Virginie; Rouanet, Jean-Louis; Roussel, Damien; Handrich, Yves; Butler, Patrick J; Duchamp, Claude

    2008-07-01

    In endotherms, regulation of the degree of mitochondrial coupling affects cell metabolic efficiency. Thus it may be a key contributor to minimizing metabolic rate during long periods of fasting. The aim of the present study was to investigate whether variation in mitochondrial avian uncoupling proteins (avUCP), as putative regulators of mitochondrial oxidative phosphorylation, may contribute to the ability of king penguins (Aptenodytes patagonicus) to withstand fasting for several weeks. After 20 days of fasting, king penguins showed a reduced rate of whole animal oxygen consumption (Vo2; -33%) at rest, together with a reduced abundance of avUCP and peroxisome proliferator-activated receptor-gamma coactivator-1alpha (PGC1-alpha) mRNA in pectoralis muscle (-54%, -36%, respectively). These parameters were restored after the birds had been refed for 3 days. Furthermore, in recently fed, but not in fasted penguins, isolated muscle mitochondria showed a guanosine diphosphate-inhibited, fatty acid plus superoxide-activated respiration, indicating the presence of a functional UCP. It was calculated that variation in mitochondrial UCP-dependent respiration in vitro may contribute to nearly 20% of the difference in resting Vo2 between fed or refed penguins and fasted penguins measured in vivo. These results suggest that the lowering of avUCP activity during periods of long-term energetic restriction may contribute to the reduction in metabolic rate and hence the ability of king penguins to face prolonged periods of fasting.

  16. Oxygen safety

    Science.gov (United States)

    ... sure you have working smoke detectors and a working fire extinguisher in your home. If you move around the house with your oxygen, you may need more than one fire extinguisher in different locations. Smoking can be very dangerous. No one should smoke ...

  17. Oxygen therapy - infants

    Science.gov (United States)

    ... breathe increased amounts of oxygen to get normal levels of oxygen in their blood. Oxygen therapy provides babies with the extra oxygen. Information Oxygen is a gas that the cells in your body need to work properly. The ...

  18. Iodine intake in Denmark

    International Nuclear Information System (INIS)

    Pedersen, K.M.; Noehr, S.B.; Laurberg, P.

    1997-01-01

    Iodine deficiency with a high frequency of goitre and, in severely affected areas, cretinism is common in some areas of the world. In Denmark the iodine intake as evaluated by urinary iodine excretion has been at a stable low level for many years, except for the part of the population now taking iodine supplementation as part of vitamin/mineral preparations. The iodine intake is lowest in the western part to the country where an epidemiological study of elderly subjects has demonstrated a high frequency of goitre and hyperthyroidism in women. This supports the suggestion of a controlled moderate increase in iodine intake via an iodine supplementation program. (au) 40 refs

  19. Effects of a high-intensity interval training program versus a moderate-intensity continuous training program on maximal oxygen uptake and blood pressure in healthy adults: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Arboleda Serna, Víctor Hugo; Arango Vélez, Elkin Fernando; Gómez Arias, Rubén Darío; Feito, Yuri

    2016-08-18

    Participation in aerobic exercise generates increased cardiorespiratory fitness, which results in a protective factor for cardiovascular disease and all-cause mortality. High-intensity interval training might cause higher increases in cardiorespiratory fitness in comparison with moderate-intensity continuous training; nevertheless, current evidence is not conclusive. To our knowledge, this is the first study to test the effect of high-intensity interval training with total load duration of 7.5 min per session. A randomized controlled trial will be performed on two groups of healthy, sedentary male volunteers (n = 44). The study protocol will include 24 exercise sessions, three times a week, including aerobic training on a treadmill and strength training exercises. The intervention group will perform 15 bouts of 30 s, each at an intensity between 90 % and 95 % of maximal heart rate. The control group will complete 40 min of continuous exercise, ranging between 65 % and 75 % of maximal heart rate. The primary outcome measure to be evaluated will be maximal oxygen uptake (VO2max), and systolic and diastolic blood pressure will be evaluated as secondary outcome measures. Waist circumference, body mass index, and body composition will also be evaluated. Epidemiological evidence shows the link between VO2max and its association with chronic conditions that trigger CVD. Therefore, finding ways to improve VO2max and reduce blood pressure it is of vital importance to public health. NCT02288403 . Registered on 4 November 2014.

  20. Peak oxygen uptake in swimmers and pupils

    Directory of Open Access Journals (Sweden)

    Emilson Colantonio

    2008-01-01

    The objectives of this study were: a to analyze the behavior of VO2MAX (absolute and relative of males of different age groups sex; b to compare VO2MAX (absolute and relative, of swimmers (SWM and schoolchildren (SCH in the same age groups. Seventy-one boys aged 7-17 years were evaluated (35 SWM and 36 SCH and distributed into the age groups 7-10, 11-14 and 15-17 years. Anthropometric measurements were taken (height, body mass and sum of skin folds and the metabolic (VO2MAX tests were carried out using VO2000® gas analysis and an Inbrasport ATL® treadmill, using a modified version of the Bruce protocol. Statistical analysis: ANOVA for repeated measures, followed by Tukey’s post hoc test (p<0.05. Absolute VO2MAX: there were statistically significant differences between all age groups and between SWM (0.99 + 0.20 and 1.27 + 0.21 L.min-1 and SCH (0.98 + 0.36 and 0.80 + 0.12 L.min-1. Relative VO2MAX: there were statistically significant differences between SWM1 and SWM2 (10.88 + 0.09 and 0.75 + 0.47 ml.kg-1.min-1 and between SCH1 and SCH3 (6.96 + 1.23 and 0.98 + 2.29 ml.kg-1.min-1, although SWM and SCH were different. The results indicate that VO2MAX increased as the subjects got older, which is the result of natural development. However, the effect of swimming training predominated. Although the behavior of the variable was similar for the 11-14 and 15-17 age groups, the figures for SWM and SCH are different at these ages, with the swimmers having higher VO2MAX.

  1. Hyperbaric oxygen therapy in periodontal diseases

    Directory of Open Access Journals (Sweden)

    Swapna A. Mahale

    2013-01-01

    Full Text Available Hyperbaric oxygen (HBO 2 has been successfully used in several medical fields. The therapeutic effect is related to elevated partial oxygen pressure in the tissues. The pressure itself enhances oxygen solubility in the tissue fluids. HBO 2 has shown to affect angiogenesis, bone metabolism and bone turnover. Studies have been conducted to analyze the effects of HBO 2 therapy on periodontal disease. HBO 2 increases local oxygen distribution, especially at the base of the periodontal pocket, which inhibits the growth of anaerobic bacteria and allows the ischemic tissues to receive an adequate intake of oxygen sufficient for a rapid recovery of cell metabolism. It is increasingly being accepted as a beneficial adjunct to diverse clinical conditions. Nonhealing ulcers, chronic wounds and refractory osteomyelitis are a few conditions for which HBO therapy (HBOT has been extensively tried out. The dental surgeons have found a good ally in HBOT in managing dental condition.

  2. Effects of exercise mode on the peak oxygen uptake and blood lactate response in boys aged 11-12 years

    Directory of Open Access Journals (Sweden)

    Fabiana Andrade Machado

    2006-09-01

    Full Text Available The objective of this study was to analyze the effects of exercise mode (running x cycling on the indexesrelated to aerobic fitness (VO2peak and blood lactate response to exercise in children. Participated of this study 20 active boys apparently healthy (age = 11.48 + 0.41 yr.; body mass = 41.38 + 10.45 kg; stature = 147.45 + 6.56 cm, with sexual maturational level 1 and 2 (pubic hair, which performed two incremental tests, with stages of 3 minutes until voluntary exhaustion, in treadmill (TR and cycle ergometer (CE, to the determination of peak oxygen uptake (VO2peak and lactate threshold (LT. The VO2peak was determined through the higher value obtained at intervals of 15 seconds. The LT was determined as the exercise intensity where the first and sustained increase of blood lactate above rest level occurred. The VO2peak (45.16 + 5.98 x 42.93 + 7.51 ml/kg/min, maximal heart rate (196.5 + 6.98 x 187.3 + 9.27 bpm, VO2 at LL (31.82 + 10.09 x 25.19 + 7.36 ml/kg/min and HR at LL (150.5 + 17.75 x 131.3 + 12.98 bpm were significantly higher in TR than CE, respectively. Thus, similar to adults, boys of 11 to 12 years present higher aerobic indexes (submaximal and maximal in running than cycling, which can haveimportant implications for healthy professionals that utilize exercise for the healthy promotion, rehabilitation and experimental designs. RESUMO O objetivo deste estudo foi analisar os efeitos do modo de exercício (corrida x ciclismo sobre os índices relacionados com a aptidão aeróbia (VO2pico e resposta de lactato ao exercício em crianças. Participaram doestudo 20 meninos, aparentemente saudáveis e ativos (idade = 11,48 + 0,41 anos; massa corporal = 41,38 + 10,45 kg; estatura = 147,45 + 6,56 cm, com níveis de maturação sexual 1 e 2 (pilosidade pubiana, que realizaram dois testes incrementais, com estágios de 3 minutos até a exaustão voluntária, em esteira rolante (ER e bicicleta ergométrica (BE, para a determinação do pico do

  3. Asymmetry of quadriceps muscle oxygenation during elite short-track speed skating.

    Science.gov (United States)

    Hesford, Catherine Mary; Laing, Stewart J; Cardinale, Marco; Cooper, Chris E

    2012-03-01

    It has been suggested that, because of the low sitting position in short-track speed skating, muscle blood flow is restricted, leading to decreases in tissue oxygenation. Therefore, wearable wireless-enabled near-infrared spectroscopy (NIRS) technology was used to monitor changes in quadriceps muscle blood volume and oxygenation during a 500-m race simulation in short-track speed skaters. Six elite skaters, all of Olympic standard (age = 23 ± 1.8 yr, height = 1.8 ± 0.1 m, mass = 80.1 ± 5.7 kg, midthigh skinfold thickness = 7 ± 2 mm), were studied. Subjects completed a 500-m race simulation time trial (TT). Whole-body oxygen consumption was simultaneously measured with muscle oxygenation in right and left vastus lateralis as measured by NIRS. Mean time for race completion was 44.8 ± 0.4 s. VO2 peaked 20 s into the race. In contrast, muscle tissue oxygen saturation (TSI%) decreased and plateaued after 8 s. Linear regression analysis showed that right leg TSI% remained constant throughout the rest of the TT (slope value = 0.01), whereas left leg TSI% increased steadily (slope value = 0.16), leading to a significant asymmetry (P skating has implications for training and performance.

  4. Effect of a High-intensity Interval Training method on maximum oxygen consumption in Chilean schoolchildren

    Directory of Open Access Journals (Sweden)

    Sergio Galdames-Maliqueo

    2017-12-01

    Full Text Available Introduction: The low levels of maximum oxygen consumption (VO2max evaluated in Chilean schoolchildren suggest the startup of trainings that improve the aerobic capacity. Objective: To analyze the effect of a High-intensity Interval Training method on maximum oxygen consumption in Chilean schoolchildren. Materials and methods: Thirty-two high school students from the eighth grade, who were divided into two groups, were part of the study (experimental group = 16 students and control group = 16 students. The main analyzed variable was the maximum oxygen consumption through the Course Navette Test. A High-intensity Interval training method was applied based on the maximum aerobic speed obtained through the Test. A mixed ANOVA was used for statistical analysis. Results: The experimental group showed a significant increase in the Maximum Oxygen Consumption between the pretest and posttest when compared with the control group (p < 0.0001. Conclusion: The results of the study showed a positive effect of the High-intensity Interval Training on the maximum consumption of oxygen. At the end of the study, it is concluded that High-intensity Interval Training is a good stimulation methodology for Chilean schoolchildren.

  5. Appetite, appetite hormone and energy intake responses to two consecutive days of aerobic exercise in healthy young men.

    Science.gov (United States)

    Douglas, Jessica A; King, James A; McFarlane, Ewan; Baker, Luke; Bradley, Chloe; Crouch, Nicole; Hill, David; Stensel, David J

    2015-09-01

    Single bouts of exercise do not cause compensatory changes in appetite, food intake or appetite regulatory hormones on the day that exercise is performed. It remains possible that such changes occur over an extended period or in response to a higher level of energy expenditure. This study sought to test this possibility by examining appetite, food intake and appetite regulatory hormones (acylated ghrelin, total peptide-YY, leptin and insulin) over two days, with acute bouts of exercise performed on each morning. Within a controlled laboratory setting, 15 healthy males completed two, 2-day long (09:00-16:00) experimental trials (exercise and control) in a randomised order. On the exercise trial participants performed 60 min of continuous moderate-high intensity treadmill running (day one: 70.1 ± 2.5% VO2peak, day two: 70.0 ± 3.2% VO2max (mean ± SD)) at the beginning of days one and two. Across each day appetite perceptions were assessed using visual analogue scales and appetite regulatory hormones were measured from venous blood samples. Ad libitum energy and macronutrient intakes were determined from meals provided two and six hours into each day and from a snack bag provided in-between trial days. Exercise elicited a high level of energy expenditure (total = 7566 ± 635 kJ across the two days) but did not produce compensatory changes in appetite or energy intake over two days (control: 29,217 ± 4006 kJ; exercise: 28,532 ± 3899 kJ, P > 0.050). Two-way repeated measures ANOVA did not reveal any main effects for acylated ghrelin or leptin (all P > 0.050). However a significant main effect of trial (P = 0.029) for PYY indicated higher concentrations on the exercise vs. control trial. These findings suggest that across a two day period, high volume exercise does not stimulate compensatory appetite regulatory changes. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Metabolic changers in oxygen transport in patients with diabetes mellitus type 2. Possibilities for correction

    Directory of Open Access Journals (Sweden)

    I Z Bondarenko

    2009-06-01

    Full Text Available Diabetes mellitus type 2 (DM2 - is an independent predictor of development of heart failure (HF. Spiroergometry - is a method for studying blood gas exchange parameters, commonly used for specification of HF. The purpose: 1. To study features of gas exchange at patients with DM2 without cardiovascular diseases in comparison with healthy control. 2. To estimate efficiency of metoprolol for correction of metabolic disturbances in patients with DM2. Materials and methods: 12 patients with DM2, aged 48,4±8, without history of cardiovascular diseases and 15 control subjects, aged 43,6±8 underwent cardio-pulmonary exercise test on treadmill, according to Bruce protocol. Exercise energy, VO2 peak, MET, VE max, VCO2 production were observed. Results: Patients with DM2 had a reduced exercise duration (p<0,001, lower peak oxygen consumption (p<0,001, VCO2 production and MET (p<0,005, than controls, representing the same state of hypoxia as in patients with ischemic heart disease (IHD of functional class 2. The introduction of metoprolol to patients with DM2 significantly increased exercise duration time and VCO2 production (p<0,005. Conclusions: 1. VO2 consumption in patients with DM2 is decreased to the same levels as in persons without DM2, who have IHD and HF. 2. Changes in oxygen-transport in persons with DM2 may serve as a marker of negative influence of the disease on cardiovascular system status. 3. Metoprolol improves parameters of cardio-respiratory system in patients with DM2.

  7. Effect of high-intensity training versus moderate training on peak oxygen uptake and chronotropic response in heart transplant recipients

    DEFF Research Database (Denmark)

    Dall, C H; Snoer, M; Christensen, S

    2014-01-01

    In heart transplant (HTx) recipients, there has been reluctance to recommend high-intensity interval training (HIIT) due to denervation and chronotropic impairment of the heart. We compared the effects of 12 weeks' HIIT versus continued moderate exercise (CON) on exercise capacity and chronotropic...... response in stable HTx recipients >12 months after transplantation in a randomized crossover trial. The study was completed by 16 HTx recipients (mean age 52 years, 75% males). Baseline peak oxygen uptake (VO2peak ) was 22.9 mL/kg/min. HIIT increased VO2peak by 4.9 ± 2.7 mL/min/kg (17%) and CON by 2.6 ± 2.......2 mL/kg/min (10%) (significantly higher in HIIT; p HIIT, systolic blood pressure decreased significantly (p = 0.037) with no significant change in CON (p = 0.241; between group difference p = 0.027). Peak heart rate (HRpeak ) increased significantly by 4.3 beats per minute (p = 0...

  8. Concurrent validity of the PAM accelerometer relative to the MTI Actigraph using oxygen consumption as a reference.

    Science.gov (United States)

    Slootmaker, S M; Chin A Paw, M J M; Schuit, A J; van Mechelen, W; Koppes, L L J

    2009-02-01

    The purpose of this study was to examine the concurrent validity of the Personal Activity Monitor (PAM) accelerometer relative to the Actigraph accelerometer using oxygen consumption as a reference, and to assess the test-retest reliability of the PAM. Thirty-two fit, normal weight adults (aged 21-54) performed two activities, treadmill walking and stair walking, while wearing the PAM, the Actigraph and the Cosmed K4b(2). Correlation coefficients and agreement in absolute energy expenditure (EE) levels between PAM, Actigraph and Cosmed were calculated. The test-retest reliability was examined among 296 PAM's using a laboratory shaker. Intraclass correlation coefficients (ICC) and coefficient of variation (CV) were determined. Correlations for treadmill walking and stair walking, respectively, were r(2)=0.95 and r(2)=0.65 for PAM with Actigraph, r(2)=0.82 and r(2)=0.93 for PAM with VO(2) and r(2)=0.64 and 0.74 for Actigraph with VO(2). Both the PAM and Actigraph underestimated EE during treadmill and stair walking by a substantial amount. The test-retest reliability of the PAM was high [ICC=0.80; 95% confidence interval (CI) (0.28;0.92) and intra-CV=1.5%]. The PAM and Actigraph accelerometer are comparable in assessing bodily movement during treadmill and stair walking. The PAM is a valid device to rank subjects in EE and can be useful in collecting objective data to monitor habitual physical activity.

  9. Excess postexercise oxygen consumption is unaffected by the resistance and aerobic exercise order in an exercise session.

    Science.gov (United States)

    Oliveira, Norton L; Oliveira, Jose

    2011-10-01

    The main purpose of this study was to compare the magnitude and duration of excess postexercise oxygen consumption (EPOC) after 2 exercise sessions with different exercise mode orders, resistance followed by aerobic exercise (R-A); aerobic by resistance exercise (A-R). Seven young men (19.6 ± 1.4 years) randomly underwent the 2 sessions. Aerobic exercise was performed on a treadmill for 30 minutes (80-85% of reserve heart rate). Resistance exercise consisted of 3 sets of 10 repetition maximum on 5 exercises. Previous to the exercise sessions, V(O2), heart rate, V(CO2), and respiratory exchange rate (RER) were measured for 15 minutes and again during recovery from exercise for 60 minutes. The EPOC magnitude was not significantly different between R-A (5.17 ± 2.26 L) and A-R (5.23 ± 2.48 L). Throughout the recovery period (60 minutes), V(O2) and HR values were significantly higher than those observed in the pre-exercise period (p better to start a training session.

  10. HIIT Augments Muscle Carnosine in the Absence of Dietary Beta-Alanine Intake.

    Science.gov (United States)

    Salles Painelli, Vitor de; Nemezio, Kleiner Márcio; Jéssica, Ana; Franchi, Mariana; Andrade, Isabel; Riani, Luiz Augusto; Saunders, Bryan; Sale, Craig; Harris, Roger Charles; Gualano, Bruno; Artioli, Guilherme Giannini

    2018-06-21

    Cross-sectional studies suggest that training can increase muscle carnosine (MCarn), although longitudinal studies have failed to confirm this. A lack of control for dietary β-alanine intake or muscle fibre type shifting may have hampered their conclusions. The purpose of the present study was to investigate the effects of high-intensity interval training (HIIT) on MCarn. Twenty vegetarian men were randomly assigned to a control (CON; n=10) or HIIT (n=10) group. HIIT was carried out on a cycle ergometer for 12 weeks, with progressive volume (6-12 series) and intensity (140-170% lactate threshold [LT]). MCarn was quantified in whole-muscle and individual fibres; expression of selected genes (CARNS, CNDP2, ABAT, TauT and PAT1) and muscle buffering capacity in vitro (βmin vitro) were also determined. Exercise tests were performed to evaluate total work done (TWD), VO2max, ventilatory thresholds (VT) and LT. TWD, VT, LT, VO2max and βmin vitro were improved in the HIIT group (all P0.05). MCarn (in mmol·kg dry muscle) increased in the HIIT (15.8±5.7 to 20.6±5.3; p=0.012) but not the CON group (14.3±5.3 to 15.0±4.9; p=0.99). In type I fibres, MCarn increased in the HIIT (from 14.4±5.9 to 16.8±7.6; p=0.047) but not the CON group (from 14.0±5.5 to 14.9±5.4; p=0.99). In type IIa fibres, MCarn increased in the HIIT group (from 18.8±6.1 to 20.5±6.4; p=0.067) but not the CON group (from 19.7±4.5 to 18.8±4.4; p=0.37). No changes in gene expression were shown. In the absence of any dietary intake of β-alanine, HIIT increased MCarn content. The contribution of increased MCarn to the total increase in βmin vitro appears to be small.

  11. Effects of Exercise Training under Hyperbaric Oxygen on Oxidative Stress Markers and Endurance Performance in Young Soccer Players: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Carlos Burgos

    2016-01-01

    Full Text Available The aim of the present study was to determine the effects of three weeks of hyperbaric oxygen (HBO2 training on oxidative stress markers and endurance performance in young soccer players. Participants (18.6±1.6 years were randomized into hyperbaric-hyperoxic (HH training (n=6 and normobaric normoxic (NN training (n=6 groups. Immediately before and after the 5th, 10th, and 15th training sessions, plasma oxidative stress markers (lipid hydroperoxides and uric acid, plasma antioxidant capacity (6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid [TROLOX], arterial blood gases, acid-base balance, bases excess (BE, and blood lactate analyses were performed. Before and after intervention, maximal oxygen uptake (VO2max and peak power output (PPO were determined. Neither HH nor NN experienced significant changes on oxidative stress markers or antioxidant capacity during intervention. VO2max and PPO were improved (moderate effect size after HH training. The results suggest that HBO2 endurance training does not increase oxidative stress markers and improves endurance performance in young soccer players. Our findings warrant future investigation to corroborate that HBO2 endurance training could be a potential training approach for highly competitive young soccer players.

  12. Low- and high-volume of intensive endurance training significantly improves maximal oxygen uptake after 10-weeks of training in healthy men.

    Directory of Open Access Journals (Sweden)

    Arnt Erik Tjønna

    Full Text Available Regular exercise training improves maximal oxygen uptake (VO2max, but the optimal intensity and volume necessary to obtain maximal benefit remains to be defined. A growing body of evidence suggests that exercise training with low-volume but high-intensity may be a time-efficient means to achieve health benefits. In the present study, we measured changes in VO2max and traditional cardiovascular risk factors after a 10 wk. training protocol that involved three weekly high-intensity interval sessions. One group followed a protocol which consisted of 4×4 min at 90% of maximal heart rate (HRmax interspersed with 3 min active recovery at 70% HRmax (4-AIT, the other group performed a single bout protocol that consisted of 1×4 min at 90% HRmax (1-AIT. Twenty-six inactive but otherwise healthy overweight men (BMI: 25-30, age: 35-45 y were randomized to either 1-AIT (n = 11 or 4-AIT (n = 13. After training, VO2max increased by 10% (∼5.0 mL⋅kg(-1⋅min(-1 and 13% (∼6.5 mL⋅kg(-1⋅min(-1 after 1-AIT and 4-AIT, respectively (group difference, p = 0.08. Oxygen cost during running at a sub-maximal workload was reduced by 14% and 13% after 1-AIT and 4-AIT, respectively. Systolic blood pressure decreased by 7.1 and 2.6 mmHg after 1-AIT and 4-AIT respectively, while diastolic pressure decreased by 7.7 and 6.1 mmHg (group difference, p = 0.84. Both groups had a similar ∼5% decrease in fasting glucose. Body fat, total cholesterol, LDL-cholesterol, and ox-LDL cholesterol only were significantly reduced after 4-AIT. Our data suggest that a single bout of AIT performed three times per week may be a time-efficient strategy to improve VO2max and reduce blood pressure and fasting glucose in previously inactive but otherwise healthy middle-aged individuals. The 1-AIT type of exercise training may be readily implemented as part of activities of daily living and could easily be translated into programs designed to improve public health

  13. Skeletal muscle-specific expression of PGC-1α-b, an exercise-responsive isoform, increases exercise capacity and peak oxygen uptake.

    Directory of Open Access Journals (Sweden)

    Miki Tadaishi

    Full Text Available Maximal oxygen uptake (VO(2max predicts mortality and is associated with endurance performance. Trained subjects have a high VO(2max due to a high cardiac output and high metabolic capacity of skeletal muscles. Peroxisome proliferator-activated receptor γ coactivator 1α (PGC-1α, a nuclear receptor coactivator, promotes mitochondrial biogenesis, a fiber-type switch to oxidative fibers, and angiogenesis in skeletal muscle. Because exercise training increases PGC-1α in skeletal muscle, PGC-1α-mediated changes may contribute to the improvement of exercise capacity and VO(2max. There are three isoforms of PGC-1α mRNA. PGC-1α-b protein, whose amino terminus is different from PGC-1α-a protein, is a predominant PGC-1α isoform in response to exercise. We investigated whether alterations of skeletal muscle metabolism by overexpression of PGC-1α-b in skeletal muscle, but not heart, would increase VO(2max and exercise capacity.Transgenic mice showed overexpression of PGC-1α-b protein in skeletal muscle but not in heart. Overexpression of PGC-1α-b promoted mitochondrial biogenesis 4-fold, increased the expression of fatty acid transporters, enhanced angiogenesis in skeletal muscle 1.4 to 2.7-fold, and promoted exercise capacity (expressed by maximum speed by 35% and peak oxygen uptake by 20%. Across a broad range of either the absolute exercise intensity, or the same relative exercise intensities, lipid oxidation was always higher in the transgenic mice than wild-type littermates, suggesting that lipid is the predominant fuel source for exercise in the transgenic mice. However, muscle glycogen usage during exercise was absent in the transgenic mice.Increased mitochondrial biogenesis, capillaries, and fatty acid transporters in skeletal muscles may contribute to improved exercise capacity via an increase in fatty acid utilization. Increases in PGC-1α-b protein or function might be a useful strategy for sedentary subjects to perform exercise

  14. [Study of oxygen consumption in infants of diabetic mothers].

    Science.gov (United States)

    Courpotin, C; Keenan, W J; Sutherland, J M; Gerbeaux, J

    1975-01-01

    The energy expenditure (VO2) was measured during the first 36 hours of life in 10 infants of diabetic mothers (IDM) and in 16 normal newborns (NB). The mean VO2 was 5,72 ml/kg/min +/- 0,4 for the NB and 4,94 ml/kg/min. +/- 0,3 for the IDM. The respiratory quotients were similar for both groups. Blood glucose determination from all IDM were greater than 44 mg%. Although the low VO2 for IDM is unexplained, several hypothesis might be anticipated: either lack of utilization of abundant endogenous glycogen stores or increased metabolism of glucose by the cells.

  15. Applied Sports Nutrition Support, Dietary Intake and Body Composition Changes of a Female Athlete Completing 26 Marathons in 26 Days: A Case Study.

    Science.gov (United States)

    McManus, Chris J; Murray, Kelly A; Parry, David A

    2017-03-01

    The aim of this case study is to describe the nutrition practices of a female recreational runner (VO 2 max 48.9 ml · kg -1 · min -1 ) who completed 26 marathons (42.195 km) in 26 consecutive days. Information relating to the nutritional intake of female runners during multi-day endurance events is extremely limited, yet the number of people participating year-on-year continues to increase. This case study reports the nutrition intervention, dietary intake, body composition changes and performance in the lead-up and during the 26 days. Prior to undertaking the 26 marathon challenge, three consultations were held between the athlete and a sports nutrition advisor; planning and tailoring the general diet and race-specific strategies to the endurance challenge. During the marathons, the mean energy and fluid intake was 1039.7 ± 207.9 kcal (607.1 - 1453.2) and 2.39 ± 0.35 L (1.98 - 3.19). Mean hourly carbohydrate intake was 38.9 g·hr -1 . 11 days following the completion of the 26 marathons, body mass had reduced by 4.6 kg and lean body mass increasing by 0.53 kg when compared with 20 days prior. This case study highlights the importance of providing general and event-specific nutrition education when training for such an event. This is particularly prudent for multi-day endurance running events.

  16. Applied Sports Nutrition Support, Dietary Intake and Body Composition Changes of a Female Athlete Completing 26 Marathons in 26 Days: A Case Study

    Directory of Open Access Journals