  1. Novel Membranes and Processes for Oxygen Enrichment

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Haiqing

    2011-11-15

    The overall goal of this project is to develop a membrane process that produces air containing 25-35% oxygen, at a cost of $25-40/ton of equivalent pure oxygen (EPO2). Oxygen-enriched air at such a low cost will allow existing air-fueled furnaces to be converted economically to oxygen-enriched furnaces, which in turn will improve the economic and energy efficiency of combustion processes significantly, and reduce the cost of CO{sub 2} capture and sequestration from flue gases throughout the U.S. manufacturing industries. During the 12-month Concept Definition project: We identified a series of perfluoropolymers (PFPs) with promising oxygen/nitrogen separation properties, which were successfully made into thin film composite membranes. The membranes showed oxygen permeance as high as 1,200 gpu and oxygen/nitrogen selectivity of 3.0, and the permeance and selectivity were stable over the time period tested (60 days). We successfully scaled up the production of high-flux PFP-based membranes, using MTR's commercial coaters. Two bench-scale spiral-wound modules with countercurrent designs were made and parametric tests were performed to understand the effect of feed flow rate and pressure, permeate pressure and sweep flow rate on the membrane module separation properties. At various operating conditions that modeled potential industrial operating conditions, the module separation properties were similar to the pure-gas separation properties in the membrane stamps. We also identified and synthesized new polymers [including polymers of intrinsic microporosity (PIMs) and polyimides] with higher oxygen/nitrogen selectivity (3.5-5.0) than the PFPs, and made these polymers into thin film composite membranes. However, these membranes were susceptible to severe aging; pure-gas permeance decreased nearly six-fold within two weeks, making them impractical for industrial applications of oxygen enrichment. We tested the effect of oxygen-enriched air on NO{sub x} emissions

  2. Oxygen enriched air using membrane for palm oil wastewater treatment

    Directory of Open Access Journals (Sweden)

    Ramlah Mohd Tajuddin

    2002-11-01

    Full Text Available A research aimed to explore new method of aeration using oxygen enriched air performance on BOD reduction of palm oil wastewater was conducted. The oxygen enriched air was obtained from an Oxygen Enriched System (OES developed using asymmetric polysulfone hollow fiber membrane with composition consisting of PSF: 22%, DMAc: 31.8%, THF: 31.8%, EtOH: 14.4%. Palm oil wastewater samples were taken from facultative pond effluent. These samples were tested for its initial biochemical oxygen demand (BOD, total suspended solids (TSS, pH, conductivity, turbidity, dissolved oxygen (DO, suspended solids (SS, and total dissolved solids (TDS before being subjected to two modes of aeration system, that is diffused air and oxygen enriched air. These water quality concentrations were tested for every 20 minutes for two-hour period during the aeration process. Results of BOD, TSS, pH, conductivity, DO, SS and TDS concentrations against time of samples from the two modes of aeration were then compared. It was found that DO concentration achieved in oxygen enriched air aeration was better than aeration using diffused air system. Aeration using OES improve the DO concentration in the wastewater and thus improve the BOD reduction and also influence other physical characteristics of wastewater. This phenomenon indicates the advantage of using air with higher oxygen concentration for wastewater aeration instead of diffused air system.

  3. Review of Membrane Oxygen Enrichment for Efficient Combustion

    Science.gov (United States)

    Ariono, Danu; Kusuma Wardani, Anita

    2017-07-01

    Oxygen enrichment from air is a simple way of increasing the efficiency of combustion process, as in oxy-combustion. Oxy-combustion has become one of the most attracting combustion technologies because of its potential to address both pollutant reduction and CO2 capture. In oxy-combustion, the fuel and recycled flue gas are combusted with oxygen enriched air (OEA). By using OEA, many benefits can be obtained, such as increasing available heat, improving ignition characteristics, flue gas reduction, increasing productivity, energy efficiency, turndown ratio, and flame stability. Membrane-based gas separation for OEA production becomes an attractive technology over the conventional technology due to the some advantages, including low capital cost, low energy consumption, compact size, and modularity. A single pass through membrane usually can enrich O2 concentration in the air up to 35% and a 50% concentration can be achieved with a double pass of membrane. The use of OEA in the combustion process eliminates the presence of nitrogen in the flue gas. Hence, the flue gas is mainly composed of CO2 and condensable water that can be easily separated. This paper gives an overview of oxy-combustion with membrane technology for oxygen enrichment process. Special attention is given to OEA production and the effect of OEA to the efficiency of combustion.

  4. Primary study of ethyl cellulose nanofiber for oxygen-enrichment membrane

    Directory of Open Access Journals (Sweden)

    Shen Jing

    2016-01-01

    Full Text Available Ethyl cellulose is widely used for oxygen-enrichment membrane, however, its nanofiber membrane was rarely developed though it behaves more excellent performance. This paper gives a preliminary study to produce oxygen-enrichment membrane by bubbfil spinning.

  5. Development of Nanofiller-Modulated Polymeric Oxygen Enrichment Membranes for Reduction of Nitrogen Oxides in Coal Combustion

    Energy Technology Data Exchange (ETDEWEB)

    Jianzhong Lou; Shamsuddin Ilias

    2010-12-31

    North Carolina A&T State University in Greensboro, North Carolina, has undertaken this project to develop the knowledge and the material to improve the oxygen-enrichment polymer membrane, in order to provide high-grade oxygen-enriched streams for coal combustion and gasification applications. Both experimental and theoretical approaches were used in this project. The membranes evaluated thus far include single-walled carbon nano-tube, nano-fumed silica polydimethylsiloxane (PDMS), and zeolite-modulated polyimide membranes. To document the nanofiller-modulated polymer, molecular dynamics simulations have been conducted to calculate the theoretical oxygen molecular diffusion coefficient and nitrogen molecular coefficient inside single-walled carbon nano-tube PDMS membranes, in order to predict the effect of the nano-tubes on the gas-separation permeability. The team has performed permeation and diffusion experiments using polymers with nano-silica particles, nano-tubes, and zeolites as fillers; studied the influence of nano-fillers on the self diffusion, free volume, glass transition, oxygen diffusion and solubility, and perm-selectivity of oxygen in polymer membranes; developed molecular models of single-walled carbon nano-tube and nano-fumed silica PDMS membranes, and zeolites-modulated polyimide membranes. This project partially supported three graduate students (two finished degrees and one transferred to other institution). This project has resulted in two journal publications and additional publications will be prepared in the near future.

  6. Cascades for natural water enrichment in deuterium and oxygen-18 using membrane permeation

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Matuszak, A.; Zakrzewska-Trznadel, G.; Van Hook, A.

    1991-01-01

    The enrichment of water in heavy isotopes by permeation through a hydrophobic membrane is described. Simple counter - current cascades are of no practical interest because of their high energy demand. A better solution is to employ a double counter - current cascade re-utilizing part of the heat of condensation. Currently employed methods of natural water enrichment in heavy isotopes are compared to the proposed membrane process. (author). 18 refs, 14 tabs, 21 figs

  7. Oxygen enrichment incineration

    International Nuclear Information System (INIS)

    Kim, Jeong Guk; Yang, Hee Chul; Park, Geun Il; Kim, Joon Hyung

    2000-10-01

    Oxygen enriched combustion technology has recently been used in waste incineration. To apply the oxygen enrichment on alpha-bearing waste incineration, which is being developed, a state-of-an-art review has been performed. The use of oxygen or oxygen-enriched air instead of air in incineration would result in increase of combustion efficiency and capacity, and reduction of off-gas product. Especially, the off-gas could be reduced below a quarter, which might reduce off-gas treatment facilities, and also increase an efficiency of off-gas treatment. However, the use of oxygen might also lead to local overheating and high nitrogen oxides (NOx) formation. To overcome these problems, an application of low NOx oxy-fuel burner and recycling of a part of off-gas to combustion chamber have been suggested

  8. Oxygen enrichment incineration

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong Guk; Yang, Hee Chul; Park, Geun Il; Kim, Joon Hyung

    2000-10-01

    Oxygen enriched combustion technology has recently been used in waste incineration. To apply the oxygen enrichment on alpha-bearing waste incineration, which is being developed, a state-of-an-art review has been performed. The use of oxygen or oxygen-enriched air instead of air in incineration would result in increase of combustion efficiency and capacity, and reduction of off-gas product. Especially, the off-gas could be reduced below a quarter, which might reduce off-gas treatment facilities, and also increase an efficiency of off-gas treatment. However, the use of oxygen might also lead to local overheating and high nitrogen oxides (NOx) formation. To overcome these problems, an application of low NOx oxy-fuel burner and recycling of a part of off-gas to combustion chamber have been suggested.

  9. Oxygen transport membrane

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to a novel composite oxygen transport membrane as well as its preparation and uses thereof.......The present invention relates to a novel composite oxygen transport membrane as well as its preparation and uses thereof....

  10. The method of water enrichment in oxygen-18

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Zakrzewska-Trznadel, G.; Van Hook, A.; Milievic, N.R.

    1996-01-01

    The process of membrane distillation has been used for water enrichment in oxygen-18. The hydrophobic PTFE membranes has been used as a boundary for liquids being at different temperatures on the each side of membrane. Example of obtained results have been shown

  11. Integration of oxygen membranes for oxygen production in cement plants

    DEFF Research Database (Denmark)

    Puig Arnavat, Maria; Søgaard, Martin; Hjuler, Klaus

    2015-01-01

    The present paper describes the integration of oxygen membranes in cement plants both from an energy, exergy and economic point of view. Different configurations for oxygen enrichment of the tertiary air for combustion in the pre-calciner and full oxy-fuel combustion in both pre-calciner and kiln...

  12. Extracorporeal membrane oxygenation (ECMO)

    African Journals Online (AJOL)

    Extracorporeal membrane oxygenation (ECMO) is not a novel therapy in the true sense of the ... Intention-to-treat analysis showed benefit for ECMO, with a relative risk ... no doubt that VV-ECMO is an advance in medical technology, and that.

  13. OXYGEN TRANSPORT CERAMIC MEMBRANES

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Sukumar Bandopadhyay; Dr. Nagendra Nagabhushana

    2000-10-01

    This is the third quarterly report on oxygen Transport Ceramic Membranes. In the following, the report describes the progress made by our university partners in Tasks 1 through 6, experimental apparatus that was designed and built for various tasks of this project, thermodynamic calculations, where applicable and work planned for the future. (Task 1) Design, fabricate and evaluate ceramic to metal seals based on graded ceramic powder/metal braze joints. (Task 2) Evaluate the effect of defect configuration on ceramic membrane conductivity and long term chemical and structural stability. (Task 3) Determine materials mechanical properties under conditions of high temperatures and reactive atmospheres. (Task 4) Evaluate phase stability and thermal expansion of candidate perovskite membranes and develop techniques to support these materials on porous metal structures. (Task 5) Assess the microstructure of membrane materials to evaluate the effects of vacancy-impurity association, defect clusters, and vacancy-dopant association on the membrane performance and stability. (Task 6) Measure kinetics of oxygen uptake and transport in ceramic membrane materials under commercially relevant conditions using isotope labeling techniques.

  14. OXYGEN TRANSPORT CERAMIC MEMBRANES

    International Nuclear Information System (INIS)

    Dr. Sukumar Bandopadhyay; Dr. Nagendra Nagabhushana

    2001-01-01

    Conversion of natural gas to liquid fuels and chemicals is a major goal for the Nation as it enters the 21st Century. Technically robust and economically viable processes are needed to capture the value of the vast reserves of natural gas on Alaska's North Slope, and wean the Nation from dependence on foreign petroleum sources. Technologies that are emerging to fulfill this need are all based syngas as an intermediate. Syngas (a mixture of hydrogen and carbon monoxide) is a fundamental building block from which chemicals and fuels can be derived. Lower cost syngas translates directly into more cost-competitive fuels and chemicals. The currently practiced commercial technology for making syngas is either steam methane reforming (SMR) or a two-step process involving cryogenic oxygen separation followed by natural gas partial oxidation (POX). These high-energy, capital-intensive processes do not always produce syngas at a cost that makes its derivatives competitive with current petroleum-based fuels and chemicals. This project has the following 6 main tasks: Task 1--Design, fabricate and evaluate ceramic to metal seals based on graded ceramic powder/metal braze joints. Task 2--Evaluate the effect of defect configuration on ceramic membrane conductivity and long term chemical and structural stability. Task 3--Determine materials mechanical properties under conditions of high temperatures and reactive atmospheres. Task 4--Evaluate phase stability and thermal expansion of candidate perovskite membranes and develop techniques to support these materials on porous metal structures. Task 5--Assess the microstructure of membrane materials to evaluate the effects of vacancy-impurity association, defect clusters, and vacancy-dopant association on the membrane performance and stability. Task 6--Measure kinetics of oxygen uptake and transport in ceramic membrane materials under commercially relevant conditions using isotope labeling techniques

  15. Oxygen Transport Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay

    2008-08-30

    The focus of this research was to develop new membrane materials by synthesizing different compounds and determining their defect structures, crystallographic structures and electrical properties. In addition to measuring electrical conductivity, oxygen vacancy concentration was also evaluated using thermogravimetry, Neutron diffraction and Moessbauer Spectroscopy. The reducing conditions (CO{sub 2}/CO/H{sub 2} gas mixtures with steam) as encountered in a reactor environment can be expected to have significant influence on the mechanical properties of the oxides membranes. Various La based materials with and without Ti were selected as candidate membrane materials for OTM. The maximum electrical conductivity of LSF in air as a function of temperature was achieved at < 600 C and depends on the concentration of Sr (acceptor dopant). Oxygen occupancy in LSF was estimated using Neutron diffractometry and Moessbauer Spectroscopy by measuring magnetic moment changes depending on the Fe{sup 3+} and Fe{sup 4+} ratio. After extensive studies of candidate materials, lanthanum ferrites (LSF and LSFT) were selected as the favored materials for the oxygen transport membrane (OTM). LSF is a very good material for an OTM because of its high electronic and oxygen ionic conductivity if long term stability and mechanical strength are improved. LSFT not only exhibits p-type behavior in the high oxygen activity regime, but also has n-type conduction in reducing atmospheres. Higher concentrations of oxygen vacancies in the low oxygen activity regime may improve the performance of LSFT as an OTM. The hole concentration is related to the difference in the acceptor and donor concentration by the relation p = [Sr'{sub La}]-[Ti{sm_bullet}{sub Fe}]. The chemical formulation predicts that the hole concentration is, p = 0.8-0.45 or 0.35. Experimental measurements indicated that p is about {approx} 0.35. The activation energy of conduction is 0.2 eV which implies that LSCF conducts via the

  16. Oxygen Transport Ceramic Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay; N. Nagabhushana; X.-D Zhou; Q. Cai; J. Yang; W.B. Yelon; W.J. James; H.U. Anderson; Alan Jacobson; C.A. Mims

    2004-05-01

    the LSCrF-2828 membrane to produce the gradients which exist under syngas generation conditions. The CO-CO{sub 2} mixtures have normal isotopic {sup 18}O abundances. The evolution of {sup 18}O on the delivery side in these experiments after an {sup 18}O pulse on the air side reveals a wealth of information about the oxygen transport processes.

  17. RECENT PROGRESS OF OXYGEN/NITROGEN SEPARATION USING MEMBRANE TECHNOLOGY

    OpenAIRE

    K. C. CHONG; S. O. LAI; H. S. THIAM; H. C. TEOH; S. L. HENG

    2016-01-01

    The oxygen-enriched air is highly demanded for various industrial applications such as medical, chemical and enhanced combustion processes. The conventional oxygen/nitrogen production is either cryogenic distillation or pressure swing adsorption (PSA). Both of these techniques possess the production capability of 20 to 300 tonnes of oxygen per day and oxygen purity of more than 95%. However, these techniques are energy intensive. Alternatively, membrane technology is an emerging technology...

  18. OXYGEN TRANSPORT CERAMIC MEMBRANES

    International Nuclear Information System (INIS)

    Dr. Sukumar Bandopadhyay; Dr. Nagendra Nagabhushana

    2002-01-01

    Conversion of natural gas to liquid fuels and chemicals is a major goal for the Nation as it enters the 21st Century. Technically robust and economically viable processes are needed to capture the value of the vast reserves of natural gas on Alaska's North Slope, and wean the Nation from dependence on foreign petroleum sources. Technologies that are emerging to fulfill this need are all based syngas as an intermediate. Syngas (a mixture of hydrogen and carbon monoxide) is a fundamental building block from which chemicals and fuels can be derived. Lower cost syngas translates directly into more cost-competitive fuels and chemicals. The currently practiced commercial technology for making syngas is either steam methane reforming (SMR) or a two-step process involving cryogenic oxygen separation followed by natural gas partial oxidation (POX). These high-energy, capital-intensive processes do not always produce syngas at a cost that makes its derivatives competitive with current petroleum-based fuels and chemicals

  19. Catalyst containing oxygen transport membrane

    Science.gov (United States)

    Christie, Gervase Maxwell; Wilson, Jamie Robyn; van Hassel, Bart Antonie

    2012-12-04

    A composite oxygen transport membrane having a dense layer, a porous support layer and an intermediate porous layer located between the dense layer and the porous support layer. Both the dense layer and the intermediate porous layer are formed from an ionic conductive material to conduct oxygen ions and an electrically conductive material to conduct electrons. The porous support layer has a high permeability, high porosity, and a high average pore diameter and the intermediate porous layer has a lower permeability and lower pore diameter than the porous support layer. Catalyst particles selected to promote oxidation of a combustible substance are located in the intermediate porous layer and in the porous support adjacent to the intermediate porous layer. The catalyst particles can be formed by wicking a solution of catalyst precursors through the porous support toward the intermediate porous layer.

  20. The development of zirconia membrane oxygen separation technology

    International Nuclear Information System (INIS)

    Chiacchi, F.T.; Badwal, S.P.S.; Velizko, V.

    2000-01-01

    The oxygen separation technology based on ceramic membranes constructed from stabilised zirconia is currently under development for applications ranging from oxygen generation or air enrichment for medical use to control of oxygen concentration or oxygen removal from gas streams and enclosures for semiconductor, food packaging and process control instrumentation industries. The technology is based on a rugged tubular design with extensive thermal cycling capability. Several single and three tube devices have been operated for periods up to 5000h. An eight tube module, as a building block for larger scale oxygen production or removal devices, has been constructed and is being evaluated. In this paper, the construction of the device, oxygen generating capacity, life time tests and performance of the ceramic membrane device under development at CSIRO will be discussed. Copyright (2000) The Australian Ceramic Society

  1. Ceria Based Composite Membranes for Oxygen Separation

    DEFF Research Database (Denmark)

    Gurauskis, Jonas; Ovtar, Simona; Kaiser, Andreas

    2014-01-01

    Mixed ionic-electronic conducting membranes for oxygen gas separation are attracting a lot of interest due to their promising potential for the pure oxygen and the syngas production. Apart from the need for a sufficiently high oxygen permeation fluxes, the prolonged stability of these membranes...... under the large oxygen potential gradients at elevated temperatures is decisive for the future applications. The gadolinium doped cerium oxide (CGO) based composite membranes are considered as promising candidates due to inherent stability of CGO phase. The CGO matrix is a main oxygen ion transporter......; meanwhile the primary role of a secondary phase in this membrane is to compensate the low electronic conductivity of matrix at intended functioning conditions. In this work thin film (15-20 μm) composite membranes based on CGO matrix and LSF electronic conducting phase were fabricated and evaluated...

  2. Blood conservation with membrane oxygenators and dipyridamole.

    Science.gov (United States)

    Teoh, K H; Christakis, G T; Weisel, R D; Madonik, M M; Ivanov, J; Wong, P Y; Mee, A V; Levitt, D; Benak, A; Reilly, P

    1987-07-01

    Cardiopulmonary bypass induces platelet activation and dysfunction, which result in platelet deposition and depletion. Reduced platelet numbers and abnormal platelet function may contribute to postoperative bleeding. A membrane oxygenator may preserve platelets and reduce bleeding more than a bubble oxygenator, and the antiplatelet agent dipyridamole may protect platelets intraoperatively and reduce bleeding postoperatively. A prospective randomized trial was performed in 44 patients undergoing elective coronary artery bypass grafting to assess the effects of the membrane oxygenator and dipyridamole on platelet counts, platelet activation products, and postoperative bleeding. Patients who were randomized to receive a bubble oxygenator and no dipyridamole had the lowest postoperative platelet counts, the greatest blood loss, and the most blood products transfused. Platelet counts were highest and blood loss was least in patients randomized to receive a membrane oxygenator and dipyridamole (p less than .05). A bubble oxygenator with dipyridamole and a membrane oxygenator without dipyridamole resulted in intermediate postoperative platelet counts and blood loss. Arterial thromboxane B2 and platelet factor 4 concentrations were elevated on cardiopulmonary bypass in all groups. Both the membrane oxygenator and dipyridamole were independently effective (by multivariate analysis) in preserving platelets. Optimal blood conservation was achieved with a membrane oxygenator and dipyridamole.

  3. Neuroradiology of extracorporeal membrane oxygenation

    International Nuclear Information System (INIS)

    Fitz, C.R.; Taylor, G.A.

    1986-01-01

    Extracorporeal membrane oxygenation (ECMO) is a new method of treating respiratory diseases, especially meconium aspiration, in newborns. It requires continued heparinization of the infant and carries the risk of intracranial bleeding. At the author's institution this risk is monitored with daily US examinations. CT is routinely performed at the end of treatment, or at other times to confirm the presence of any pathology that might require the cessation of ECMO treatment. Of the first 62 newborns receiving ECMO therapy, all underwent daily US examinations; 48 underwent CT. In ten patients (16%) hemorrhages developed that were detected on US; the incidence was evenly distributed between primary intraventricular and parenchymal bleeding. Five of these patients died without CT having been performed. Follow-up CT scans in another five also showed hemorrhage. In five patients CT scans showed definite small punctate areas of bleeding in unusual locations, not visible on US. CT scans in another four patients were suspicious for similar bleeding. One subarachnoid hemorrhage was found. In three infants performed widening of the interhemispheric fissure was seen, and six others had probable abnormal widening of the fissure. Overall, 14 (29%) CT scans were definitely abnormal and 21% probably abnormal. Follow-up has not been significantly long enough to allow evaluation the significance of the smaller bleeding areas and interhemispheric fissure widening seen on CT. At this time, both US and CT have a definite role in the care of newborn infants undergoing ECMO

  4. Cheap Thin Film Oxygen Membranes

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention provides a membrane, comprising a porous support layer a gas tight electronically and ionically conducting membrane layer and a catalyst layer, characterized in that the electronically and ionically conducting membrane layer is formed from a material having a crystallite...... structure with a crystal size of about 1 to 100 nm, and a method for producing same....

  5. Ceramic oxygen transport membrane array reactor and reforming method

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Sean M.; Christie, Gervase Maxwell; Robinson, Charles; Wilson, Jamie R.; Gonzalez, Javier E.; Doraswami, Uttam R.

    2016-11-08

    The invention relates to a commercially viable modular ceramic oxygen transport membrane reforming reactor configured using repeating assemblies of oxygen transport membrane tubes and catalytic reforming reactors.

  6. GSL-enriched membrane microdomains in innate immune responses.

    Science.gov (United States)

    Nakayama, Hitoshi; Ogawa, Hideoki; Takamori, Kenji; Iwabuchi, Kazuhisa

    2013-06-01

    Many pathogens target glycosphingolipids (GSLs), which, together with cholesterol, GPI-anchored proteins, and various signaling molecules, cluster on host cell membranes to form GSL-enriched membrane microdomains (lipid rafts). These GSL-enriched membrane microdomains may therefore be involved in host-pathogen interactions. Innate immune responses are triggered by the association of pathogens with phagocytes, such as neutrophils, macrophages and dendritic cells. Phagocytes express a diverse array of pattern-recognition receptors (PRRs), which sense invading microorganisms and trigger pathogen-specific signaling. PRRs can recognize highly conserved pathogen-associated molecular patterns expressed on microorganisms. The GSL lactosylceramide (LacCer, CDw17), which binds to various microorganisms, including Candida albicans, is expressed predominantly on the plasma membranes of human mature neutrophils and forms membrane microdomains together with the Src family tyrosine kinase Lyn. These LacCer-enriched membrane microdomains can mediate superoxide generation, migration, and phagocytosis, indicating that LacCer functions as a PRR in innate immunity. Moreover, the interactions of GSL-enriched membrane microdomains with membrane proteins, such as growth factor receptors, are important in mediating the physiological properties of these proteins. Similarly, we recently found that interactions between LacCer-enriched membrane microdomains and CD11b/CD18 (Mac-1, CR3, or αMβ2-integrin) are significant for neutrophil phagocytosis of non-opsonized microorganisms. This review describes the functional role of LacCer-enriched membrane microdomains and their interactions with CD11b/CD18.

  7. RECENT PROGRESS OF OXYGEN/NITROGEN SEPARATION USING MEMBRANE TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    K. C. CHONG

    2016-07-01

    Full Text Available The oxygen-enriched air is highly demanded for various industrial applications such as medical, chemical and enhanced combustion processes. The conventional oxygen/nitrogen production is either cryogenic distillation or pressure swing adsorption (PSA. Both of these techniques possess the production capability of 20 to 300 tonnes of oxygen per day and oxygen purity of more than 95%. However, these techniques are energy intensive. Alternatively, membrane technology is an emerging technology in gas separation as it requires low energy consumption and relatively moderate production volume, if compared to the conventional gas production techniques. These advantages have spurred much interest from industries and academics to speed up the commercial viability of the O2/N2 separation via membrane technology. In this review, the conventional and membrane technologies in O2/N2 separation, as well as recent development of membrane fabrication techniques and materials are reviewed. The latest membrane performance in O2/N2 separation is also tabulated and discussed.

  8. Hybrid membrane--PSA system for separating oxygen from air

    Science.gov (United States)

    Staiger, Chad L [Albuquerque, NM; Vaughn, Mark R [Albuquerque, NM; Miller, A Keith [Albuquerque, NM; Cornelius, Christopher J [Blackburg, VA

    2011-01-25

    A portable, non-cryogenic, oxygen generation system capable of delivering oxygen gas at purities greater than 98% and flow rates of 15 L/min or more is described. The system consists of two major components. The first component is a high efficiency membrane capable of separating argon and a portion of the nitrogen content from air, yielding an oxygen-enriched permeate flow. This is then fed to the second component, a pressure swing adsorption (PSA) unit utilizing a commercially available, but specifically formulated zeolite compound to remove the remainder of the nitrogen from the flow. The system is a unique gas separation system that can operate at ambient temperatures, for producing high purity oxygen for various applications (medical, refining, chemical production, enhanced combustion, fuel cells, etc . . . ) and represents a significant advance compared to current technologies.

  9. Extracorporeal Membrane Oxygenation for Complicated Scrub Typhus

    Directory of Open Access Journals (Sweden)

    Eun Sun Kim

    Full Text Available Scrub typhus is a mite-borne infectious disease caused by Orientia tsutsugamushi . Although early diagnosis and appropriate antibiotic therapy improve the prognosis for the majority of patients, life-threatening complications are not uncommon. Here, we present a case of successful veno-veno-type extracorporeal membrane oxygenation for scrub typhus-induced complications, including acute respiratory distress syndrome, myocarditis and multi-organ dysfunction. To our knowledge, this is the first case report of successful extracorporeal membrane oxygenation in complicated scrub typhus in Korea.

  10. Experimental study on ceramic membrane technology for onboard oxygen generation

    OpenAIRE

    Jiang Dongsheng; Bu Xueqin; Sun Bing; Lin Guiping; Zhao Hongtao; Cai Yan; Fang Ling

    2016-01-01

    The ceramic membrane oxygen generation technology has advantages of high concentration of produced oxygen and potential nuclear and biochemical protection capability. The present paper studies the ceramic membrane technology for onboard oxygen generation. Comparisons are made to have knowledge of the effects of two kinds of ceramic membrane separation technologies on oxygen generation, namely electricity driven ceramic membrane separation oxygen generation technology (EDCMSOGT) and pressure d...

  11. Centrifugation. A theoretical study of oxygen enrichment by centrifugation

    Energy Technology Data Exchange (ETDEWEB)

    Kierkegaard, P.; Raetz, E.

    1998-12-01

    In the present paper we first investigate what happens if we fill a cylinder with air, close it and rotate it. The results show that no matter which peripheral speed is used, it is not possible by means of the radial separation effect alone, to enrich the oxygen concentration from the previous 21% to more then 23.3%, which is of no practical value. In case of a too low enrichment in one centrifuge, the wanted material from this centrifuge can be used as an input for a second centrifuge and so on, in this way forming a cascade of centrifuges. Oxygen will be enriched in each step, until the desired concentration is reached. Cascading was the technology in the very beginning by enrichment plants for uraniumhexaflouride, used for atomic weapons and nuclear power plants. In this study we try to avoid cascading by aiming for higher separation factors. Therefore, we next investigate the possibilities of using a countercurrent centrifuge where in principle the enriched gas is subjected to several centrifugation in the same centrifuge. The calculations show, that in this way it is possible to produce nearly a 100% pure oxygen (polluted with some heavier molecules like argon) in one machine. Our third step was to calculate the amount of oxygen produced per hour. Using a countercurrent centrifuge of the Zippe type, 100 cm high and 20 cm in diameter, it is or will be possible in the near future to produce 17 g enriched air per hour enriched to 50% oxygen. That corresponds to processing 1 m{sup 3} atmospherical air in the period of approximately 24 hours. This is not very impressive. Our fourth step was to estimate the amount of power used for producing this amount of oxygen. A rough, but complicated, estimate shows that the power consumption at the production level will be about the double of the consumption used today. The overall conclusion is, that centrifugation as a production method for oxygen (or nitrogen) will not be competitive with the currently used method in the

  12. HIGH PERFORMANCE CERIA BASED OXYGEN MEMBRANE

    DEFF Research Database (Denmark)

    2014-01-01

    The invention describes a new class of highly stable mixed conducting materials based on acceptor doped cerium oxide (CeO2-8 ) in which the limiting electronic conductivity is significantly enhanced by co-doping with a second element or co- dopant, such as Nb, W and Zn, so that cerium and the co......-dopant have an ionic size ratio between 0.5 and 1. These materials can thereby improve the performance and extend the range of operating conditions of oxygen permeation membranes (OPM) for different high temperature membrane reactor applications. The invention also relates to the manufacturing of supported...

  13. Experimental Validation of a Permeability Model for Enrichment Membranes

    International Nuclear Information System (INIS)

    Orellano, Pablo; Brasnarof, Daniel; Florido Pablo

    2003-01-01

    An experimental loop with a real scale diffuser, in a single enrichment-stage configuration, was operated with air at different process conditions, in order to characterize the membrane permeability.Using these experimental data, an analytical geometric-and-morphologic-based model was validated.It is conclude that a new set of independent measurements, i.e. enrichment, is necessary in order to fully characterize diffusers, because of its internal parameters are not univocally determinated with permeability experimental data only

  14. Decommissioning Combustible Waste Treatment using Oxygen-Enriched Incinerator

    Energy Technology Data Exchange (ETDEWEB)

    Min, Byungyoun; Lee, Yoonji; Yun, Gyoungsu; Lee, Kiwon; Moon, Jeikwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The aim of the paper is current status of treatment for the decommissioning combustible waste in KAERI and for the purpose of the volume reduction and clearance for decommissioning combustible wastes generated by the decommissioning projects. The incineration technology has been selected for the treatment of combustible wastes. About 34 tons of decommissioning combustible waste has been treated using Oxygen Enriched incineration. Temperature, pressure of major components, stack gas concentration, i. e., SOx, NOx, CO, CO{sub 2} and HCl, and the residual oxygen were measured. Measured major parameters during normal operation were sustained on a stable status within a criteria operation condition. Oxygen enriched air, 22vol. % (dry basis) was used for stable incineration. The volume reduction ratio has achieved about 1/117. The incineration with decommissioning radioactive combustible waste is possible with moderate oxygen enrichment of 22 vol.% (dry basis) into the supply air. The incineration facility operated quite smoothly through the analysis major critical parameters of off-gas. The pressure, off-gas flow and temperature of major components remained constant within the range specified. The measures gases and particulate materials in stack were considerably below the regulatory limits. The achieved volume reduction ratio through incineration is about 1/117.

  15. Experimental study on ceramic membrane technology for onboard oxygen generation

    Directory of Open Access Journals (Sweden)

    Jiang Dongsheng

    2016-08-01

    Full Text Available The ceramic membrane oxygen generation technology has advantages of high concentration of produced oxygen and potential nuclear and biochemical protection capability. The present paper studies the ceramic membrane technology for onboard oxygen generation. Comparisons are made to have knowledge of the effects of two kinds of ceramic membrane separation technologies on oxygen generation, namely electricity driven ceramic membrane separation oxygen generation technology (EDCMSOGT and pressure driven ceramic membrane separation oxygen generation technology (PDCMSOGT. Experiments were conducted under different temperatures, pressures of feed air and produced oxygen flow rates. On the basis of these experiments, the flow rate of feed air, electric power provided, oxygen recovery rate and concentration of produced oxygen are compared under each working condition. It is concluded that the EDCMSOGT is the oxygen generation means more suitable for onboard conditions.

  16. Studies of MHD generator performance with oxygen enriched coal combustion

    Science.gov (United States)

    Wormhoudt, J.; Yousefian, V.; Kolb, C. E.; Martinez-Sanchez, M.

    1980-07-01

    This paper presents calculations made using the Aerodyne PACKAGE (Plasma Analysis, Chemical Kinetics, and Generator Efficiency) computer code which bear on two questions which arise in connection with choices between oxygen enrichment and air preheating to attain the high combustion temperatures needed for open-cycle, coal-fired MHD power generation. The first question is which method produces the highest enthalpy extraction per unit channel length. The second is, in test facilities intended to study tradeoffs between oxygen enrichment and preheated air, can good generator performance be obtained from the same physical channel for different combustor compositions. The answer to the first question is found to depend on what combustor conditions are taken to be comparable. As for the second question, it is found that operation with channel input from off-design combustor conditions can cause serious problems, which can be partially alleviated by changing the channel load factors.

  17. Oxygen enriched combustion system performance study. Phase 2: 100 percent oxygen enriched combustion in regenerative glass melters, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Tuson, G.B.; Kobayashi, H.; Campbell, M.J.

    1994-08-01

    The field test project described in this report was conducted to evaluate the energy and environmental performance of 100% oxygen enriched combustion (100% OEC) in regenerative glass melters. Additional objectives were to determine other impacts of 100% OEC on melter operation and glass quality, and to verify on a commercial scale that an on-site Pressure Swing Adsorption oxygen plant can reliably supply oxygen for glass melting with low electrical power consumption. The tests constituted Phase 2 of a cooperative project between the United States Department of Energy, and Praxair, Inc. Phase 1 of the project involved market and technical feasibility assessments of oxygen enriched combustion for a range of high temperature industrial heating applications. An assessment of oxygen supply options for these applications was also performed during Phase 1, which included performance evaluation of a pilot scale 1 ton per day PSA oxygen plant. Two regenerative container glass melters were converted to 100% OEC operation and served as host sites for Phase 2. A 75 ton per day end-fired melter at Carr-Lowrey Glass Company in Baltimore, Maryland, was temporarily converted to 100% OEC in mid- 1990. A 350 tpd cross-fired melter at Gallo Glass Company in Modesto, California was rebuilt for permanent commercial operation with 100% OEC in mid-1991. Initially, both of these melters were supplied with oxygen from liquid storage. Subsequently, in late 1992, a Pressure Swing Adsorption oxygen plant was installed at Gallo to supply oxygen for 100% OEC glass melting. The particular PSA plant design used at Gallo achieves maximum efficiency by cycling the adsorbent beds between pressurized and evacuated states, and is therefore referred to as a Vacuum/Pressure Swing Adsorption (VPSA) plant.

  18. High Pressure and High Temperature State of Oxygen Enriched Ice

    Science.gov (United States)

    LI, M.; Zhang, S.; Jeanloz, R.; Militzer, B.

    2016-12-01

    Interior models for Uranus and Neptune include a hydrogen/helium/water outer envelope and a core of rock and metal at the center, with superionic water-rich ice proposed as comprising an intermediate layer. Here we consider an oxygen-enriched ice, such as H2O2 hydrogen peroxide (± water), that could form through chemical reaction between water-rich and underlying rocky (i.e., oxygen-rich) layers. As oxygen and its compounds (e.g., H2O, SiO2) form metallic fluids at pressures above 100-150 GPa, the problem amounts to considering oxygen alloying of semiconducting or metallic water. The density of H2O2 is 1.45 g/cc at ambient pressure and 0° C, increasing to 1.71 g/cc in the solid state at about -20° C. There are no Hugoniot data beyond 30 GPa, so we estimated Hugoniots for H2O2 with different initial densities, using both a mixing model based on Hugoniot data for H2O2 and 1/2 O2 (molar volume summation under pressure) and ab initio calculations for unreacted H2O2. The results agree with each other to pressures of about 200 GPa, and the ab initio calculations show evidence of a superionic state at temperatures as low as 500 K, much lower than for water ice. Hydrogen peroxide is expected to be liquid along planetary isentropes for Uranus and Neptune, suggesting that H2O2 may not be present as a pure compound in these planets. Instead, oxygen-enriched H2O ice may be the relevant form of water and oxygen, and might be produced in the laboratory by way of dynamic compression of H2O2 or laser-heating of statically compressed H2O + O2 and/or H2O2.

  19. Ceramic oxygen transport membrane array reactor and reforming method

    Science.gov (United States)

    Kelly, Sean M.; Christie, Gervase Maxwell; Robinson, Charles; Wilson, Jamie R; Gonzalez, Javier E.; Doraswami, Uttam R.

    2017-10-03

    The invention relates to a commercially viable modular ceramic oxygen transport membrane system for utilizing heat generated in reactively-driven oxygen transport membrane tubes to generate steam, heat process fluid and/or provide energy to carry out endothermic chemical reactions. The system provides for improved thermal coupling of oxygen transport membrane tubes to steam generation tubes or process heater tubes or reactor tubes for efficient and effective radiant heat transfer.

  20. Characterization of oxygen dimer-enriched silicon detectors

    CERN Document Server

    Boisvert, V; Moll, M; Murin, L I; Pintilie, I

    2005-01-01

    Various types of silicon material and silicon p+n diodes have been treated to increase the concentration of the oxygen dimer (O2i) defect. This was done by exposing the bulk material and the diodes to 6 MeV electrons at a temperature of about 350 °C. FTIR spectroscopy has been performed on the processed material confirming the formation of oxygen dimer defects in Czochralski silicon pieces. We also show results from TSC characterization on processed diodes. Finally, we investigated the influence of the dimer enrichment process on the depletion voltage of silicon diodes and performed 24 GeV/c proton irradiations to study the evolution of the macroscopic diode characteristics as a function of fluence.

  1. Factors Determining the Oxygen Permeability of Biological Membranes: Oxygen Transport Across Eye Lens Fiber-Cell Plasma Membranes.

    Science.gov (United States)

    Subczynski, Witold Karol; Widomska, Justyna; Mainali, Laxman

    2017-01-01

    Electron paramagnetic resonance (EPR) spin-label oximetry allows the oxygen permeability coefficient to be evaluated across homogeneous lipid bilayer membranes and, in some cases, across coexisting membrane domains without their physical separation. The most pronounced effect on oxygen permeability is observed for cholesterol, which additionally induces the formation of membrane domains. In intact biological membranes, integral proteins induce the formation of boundary and trapped lipid domains with a low oxygen permeability. The effective oxygen permeability coefficient across the intact biological membrane is affected not only by the oxygen permeability coefficients evaluated for each lipid domain but also by the surface area occupied by these domains in the membrane. All these factors observed in fiber cell plasma membranes of clear human eye lenses are reviewed here.

  2. Optimal time for initiating extracorporeal membrane oxygenation.

    Science.gov (United States)

    Haile, Dawit T; Schears, Gregory J

    2009-09-01

    The technical evolution of extracorporeal membrane oxygenation (ECMO) coincides with the vast improvement in intensive care medicine of the past 4 decades. Extracorporeal circulatory technology substitutes for acutely failed cardiac or pulmonary function until these organs regain sustainable function through goal-oriented intensive care practice. The technology has been validated to improve survival in select patients who would otherwise have 100% mortality. This is by far the most complex life-sustaining technology employed and thus can contribute significant risks such that the decision to institute ECMO requires prompt risk and benefit analysis. Delaying the institution of ECMO may cause irreversible pulmonary and cardiac injuries in addition to other organs. Therefore, the optimal time of initiating ECMO support is crucial to the survival of a critically ill patient.

  3. Separation of gases through gas enrichment membrane composites

    Science.gov (United States)

    Swedo, Raymond J.; Kurek, Paul R.

    1988-01-01

    Thin film composite membranes having as a permselective layer a film of a homopolymer of certain vinyl alkyl ethers are useful in the separation of various gases. Such homopolymers have a molecular weight of greater than 30,000 and the alkyl group of the vinyl alkyl monomer has from 4 to 20 carbon atoms with branching within the alkyl moiety at least at the carbon atom bonded to the ether oxygen or at the next adjacent carbon atom. These membranes show excellent hydrolytic stability, especially in the presence of acidic or basic gaseous components.

  4. Volume Reduction of Decommissioning Burnable Waste with Oxygen Enrich Incinerator

    Energy Technology Data Exchange (ETDEWEB)

    Min, B. Y.; Yang, D. S.; Lee, K. W.; Choi, J. W. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The incineration technology is an effective treatment method that contains hazardous chemicals as well as radioactive contamination. The volume reduction of the combustible wastes through the incineration technologies has merits from the view point of a decrease in the amount of waste to be disposed of resulting in a reduction of the disposal cost. Incineration is generally accepted as a method of reducing the volume of radioactive waste. The incineration technology is an effective treatment method that contains hazardous chemicals as well as radioactive contamination. This paper covers the general facility operation of an oxygen-enriched incinerator for the treatment of decommissioning wastes generated from a decommissioning project. The combustible wastes have been treated by the utilization of incinerator the capacity of the average 20 kg/hr. The decommissioning combustible waste of about 31 tons has been treated using Oxygen Enriched incinerator by at the end of 2016. The off-gas flow and temperature were maintained constant or within the desired range. The measured gases and particulate materials in the stack were considerably below the regulatory limits.

  5. Volume Reduction of Decommissioning Burnable Waste with Oxygen Enrich Incinerator

    International Nuclear Information System (INIS)

    Min, B. Y.; Yang, D. S.; Lee, K. W.; Choi, J. W.

    2016-01-01

    The incineration technology is an effective treatment method that contains hazardous chemicals as well as radioactive contamination. The volume reduction of the combustible wastes through the incineration technologies has merits from the view point of a decrease in the amount of waste to be disposed of resulting in a reduction of the disposal cost. Incineration is generally accepted as a method of reducing the volume of radioactive waste. The incineration technology is an effective treatment method that contains hazardous chemicals as well as radioactive contamination. This paper covers the general facility operation of an oxygen-enriched incinerator for the treatment of decommissioning wastes generated from a decommissioning project. The combustible wastes have been treated by the utilization of incinerator the capacity of the average 20 kg/hr. The decommissioning combustible waste of about 31 tons has been treated using Oxygen Enriched incinerator by at the end of 2016. The off-gas flow and temperature were maintained constant or within the desired range. The measured gases and particulate materials in the stack were considerably below the regulatory limits.

  6. Modeling the effects of late cycle oxygen enrichment on diesel engine combustion and emissions

    International Nuclear Information System (INIS)

    Mather, D. K.; Foster, D. E.; Poola, R. B.; Longman, D. E.; Chanda, A.; Vachon, T. J.

    2002-01-01

    A multidimensional simulation of Auxiliary Gas Injection (AGI) for late cycle oxygen enrichment was exercised to assess the merits of AGI for reducing the emissions of soot from heavy duty diesel engines while not adversely affecting the NO(sub x) emissions of the engine. Here, AGI is the controlled enhancement of mixing within the diesel engine combustion chamber by high speed jets of air or another gas. The engine simulated was a Caterpillar 3401 engine. For a particular operating condition of this engine, the simulated soot emissions of the engine were reduced by 80% while not significantly affecting the engine-out NO(sub x) emissions compared to the engine operating without AGI. The effects of AGI duration, timing, and orientation are studied to confirm the window of opportunity for realizing lower engine-out soot while not increasing engine out NO(sub x) through controlled enhancement of in-cylinder mixing. These studies have shown that this window occurs during the late combustion cycle, from 20 to 60 crank angle degrees after top-dead-center. During this time, the combustion chamber temperatures are sufficiently high that soot oxidation increases in response in increased mixing, but the temperature is low enough that NO(sub x) reactions are quenched. The effect of the oxygen composition of the injected air is studied for the range of compositions between 21% and 30% oxygen by volume. This is the range of oxygen enrichment that is practical to produce from an air separation membrane. Simulations showed that this level of oxygen enrichment is insufficient to provide an additional benefit by either increasing the level of soot oxidation or prolonging the window of opportunity for increasing soot oxidation through enhanced mixing

  7. Ultramicroelectrode studies of oxygen reduction in polyelectrolyte membranes

    Energy Technology Data Exchange (ETDEWEB)

    Holdcroft, S.; Abdou, M.S.; Beattie, P.; Basura, V. [Simon Fraser Univ., Burnaby, BC (Canada). Dept. of Chemistry

    1997-12-31

    A study on the oxygen reduction reaction in a solid state electrochemical cell was presented. The oxygen reduction reaction is a rate limiting reaction in the operation of solid polymer electrolyte fuel cells which use H{sub 2} and O{sub 2}. Interest in the oxygen reduction reaction of platinum electrodes in contact with Nafion electrolytes stems from its role in fuel cell technology. The kinetics of the oxygen reduction reaction in different polyelectrolyte membranes, such as Nafion and non-Nafion membranes, were compared. The electrode kinetics and mass transport parameters of the oxygen reduction reaction in polyelectrolyte membranes were measured by ultramicroelectrode techniques. The major difference found between these two classes of membrane was the percentage of water, which is suggestive of superior electrochemical mass transport properties of the non-Nafion membranes. 2 refs. 1 fig.

  8. Oxygen transport membranes for biomass gasification and cement industry

    DEFF Research Database (Denmark)

    Cheng, Shiyang

    .1Ce0.9-xO1.95-δ increases with increasing concentration of Pr. The drastic decline of activation energy of electron hole migration (10-15 at.%) indicates a drastic decrease of hopping energy as continuous percolating “Pr-path” forms in the Face-Centred Cubic (FCC) Unit Cell. This provides a new...... of structural supports. An asymmetric (thin dense layer on a porous support) dual phase composite membrane of 70 vol.% Gd0.1Ce0.9O1.95-δ-30 vol.% La0.6Sr0.4FeO3-δ (GCO-LSF) was fabricated by a “one step” phase-inversion tape casting. Oxygen flux measurement as well as electrical conductivity relaxation......-1 at 850°C was measured over 300 hours in O2/N2. Segregation of barium sulphate and cobalt oxide was found on the surface of the dense membranes, which is ascribed to the reaction between sulphur-containing binder (PESF) and BSCFZ powder. Significant loss of Co, Sr and Fe and enrichment of BaSO4...

  9. Extracorporeal membrane oxygenation for refractory cardiac arrest

    Directory of Open Access Journals (Sweden)

    Steven A Conrad

    2017-01-01

    Full Text Available Extracorporeal cardiopulmonary resuscitation (ECPR is the use of rapid deployment venoarterial (VA extracorporeal membrane oxygenation to support systemic circulation and vital organ perfusion in patients in refractory cardiac arrest not responding to conventional cardiopulmonary resuscitation (CPR. Although prospective controlled studies are lacking, observational studies suggest improved outcomes compared with conventional CPR when ECPR is instituted within 30-60 min following cardiac arrest. Adult and pediatric patients with witnessed in-hospital and out-of-hospital cardiac arrest and good quality CPR, failure of at least 15 min of conventional resuscitation, and a potentially reversible cause for arrest are candidates. Percutaneous cannulation where feasible is rapid and can be performed by nonsurgeons (emergency physicians, intensivists, cardiologists, and interventional radiologists. Modern extracorporeal systems are easy to prime and manage and are technically easy to manage with proper training and experience. ECPR can be deployed in the emergency department for out-of-hospital arrest or in various inpatient units for in-hospital arrest. ECPR should be considered for patients with refractory cardiac arrest in hospitals with an existing extracorporeal life support program, able to provide rapid deployment of support, and with resources to provide postresuscitation evaluation and management.

  10. Mechanical ventilation during extracorporeal membrane oxygenation.

    Science.gov (United States)

    Schmidt, Matthieu; Pellegrino, Vincent; Combes, Alain; Scheinkestel, Carlos; Cooper, D Jamie; Hodgson, Carol

    2014-01-21

    The timing of extracorporeal membrane oxygenation (ECMO) initiation and its outcome in the management of respiratory and cardiac failure have received considerable attention, but very little attention has been given to mechanical ventilation during ECMO. Mechanical ventilation settings in non-ECMO studies have been shown to have an effect on survival and may also have contributed to a treatment effect in ECMO trials. Protective lung ventilation strategies established for non-ECMO-supported respiratory failure patients may not be optimal for more severe forms of respiratory failure requiring ECMO support. The influence of positive end-expiratory pressure on the reduction of the left ventricular compliance may be a matter of concern for patients receiving ECMO support for cardiac failure. The objectives of this review were to describe potential mechanisms for lung injury during ECMO for respiratory or cardiac failure, to assess the possible benefits from the use of ultra-protective lung ventilation strategies and to review published guidelines and expert opinions available on mechanical ventilation-specific management of patients requiring ECMO, including mode and ventilator settings. Articles were identified through a detailed search of PubMed, Ovid, Cochrane databases and Google Scholar. Additional references were retrieved from the selected studies. Growing evidence suggests that mechanical ventilation settings are important in ECMO patients to minimize further lung damage and improve outcomes. An ultra-protective ventilation strategy may be optimal for mechanical ventilation during ECMO for respiratory failure. The effects of airway pressure on right and left ventricular afterload should be considered during venoarterial ECMO support of cardiac failure. Future studies are needed to better understand the potential impact of invasive mechanical ventilation modes and settings on outcomes.

  11. Simulation training for extracorporeal membrane oxygenation

    Directory of Open Access Journals (Sweden)

    Roberta Brum

    2015-01-01

    Full Text Available Background: Extracorporeal membrane oxygenation (ECMO is a complex treatment. Despite this, there are a lack of training programs designed to develop relevant clinical and nonclinical skills required for ECMO specialists. The aim of the current study was to describe the design, implementation and evaluation of a 1-day simulation course for delivering training in ECMO. Methods: A 1-day simulation course was developed with educational and intensive care experts. First, the delegates received a lecture on the principles of simulation training and the importance of human factors. This was, followed by a practical demonstration and discussion of the ECMO circuit, console components, circuit interactions effects and potential complications. There were then five ECMO simulation scenarios with debriefing that covered technical and nontechnical issues. The course culminated in a knowledge-based assessment. Course outcomes were assessed using purpose-designed questionnaires. Results: We held 3 courses with a total of 14 delegates (9 intensive care nurses, 3 adult intensive care consultants and 2 ECMO technicians. Following the course, 8 (57% gained familiarity in troubleshooting an ECMO circuit, 6 (43% increased their familiarity with the ECMO pump and circuit, 8 (57% perceived an improvement in their communication skills and 7 (50% perceived an improvement in their leadership skills. At the end of the course, 13 (93% delegates agreed that they felt more confident in dealing with ECMO. Conclusions: Simulation-training courses may increase knowledge and confidence in dealing with ECMO emergencies. Further studies are indicated to determine whether simulation training improves clinical outcomes and translates to reduced complication rates in patients receiving ECMO.

  12. Neonatal respiratory extracorporeal membrane oxygenation (ECMO) referrals.

    LENUS (Irish Health Repository)

    El-Khuffash, A

    2011-03-01

    Extracorporeal membrane oxygenation (ECMO) is a complex technique for providing life support in neonatal respiratory failure. T UK Collaborative ECMO trial demonstrated cost-effectiveness and substantial improvements in neurological morbidity and mortality. Currently, infants requiring ECMO in Ireland are referred to one of various centres in the UK and Scandinavia. We aimed to review the number of infants referred from Ireland for respiratory ECMO. All infants with a non-cardiac condition referred from Ireland for ECMO were reviewed for diagnosis and outcomes. Eleven infants required ECMO between June 2006 and January 2009 and were referred to the Scandinavian team for ECMO transport although one infant improved and did not require ECMO following the arrival of the team. Four infants died: one infant died prior to arrival of the ECMO team, 3 infants had fatal diagnoses and one infant with congenital diaphragmatic hernia received pre-op ECMO. The median (inter-quartile range) gestational age was 39.7 (38.3-40.7) weeks and birth weight of 3.7 (3.2-4.0) kg. The median age at the decision to transfer for ECMO was 13h (4-123) and the team arrived at 23 h (12-132). All infants had a normal cranial ultrasound and echo prior to ECMO and 2 infants had an abnormal MRI post-ECMO. The time on ECMO was 9 days (3-17) and total length of hospital stay was 32 d (23-36). There were no pre-ECMO clinical or biochemical

  13. Collateral flow after extracorporeal membrane oxygenation

    International Nuclear Information System (INIS)

    Smith, A.S.; Wiznitzer, M.; Haacke, E.M.

    1990-01-01

    MR angiography was used to evaluate collateral flow after extracorporal membrane oxygenation (ECMO) in patients with permanent ligation of the right common carotid artery (RCCA). One year after ECMO, MR angiography of the cerebral circulation was performed in 11 survivors and MR angiography of the neck in seven. The diameters of the left common carotid (LCCA) and vertebral (Vert) arteries in the neck and of the basilar (Bas) and internal carotid arteries in the head were measured. Ratios of the artery diameters were compared with those of seven children (aged 6 months - 17 years) who had normal MR angiographic and brain MR imaging studies. Compared with carotid artery diameter, the ECMO population had proportionately larger vertebral (RVert/LCCA, -0.82 ± 0.12 vs 0.56 ± 0.20 [<.02], LVert/LCCA, -0.86 ± 0.15 vs 0.67 ± 0.05 [P < .02] and basilar artery diameters (LICA/Bas, -0.91 ± 0.15 vs 1.49 ± 0.48 [p < .003]) than did control subjects. Ratios in five children with enlarged RPComA after ECMO were not significantly different from those in controls. The RICA was present and smaller than the LICA in the ECMO population, but not in control subjects (RICA/LICA, -0.75 ± 0.06 vs 0.91 ± 0.23 [p < .05]). Increased vertebral and basilar artery flow is a response to RCCA ligation in the neonate and is independent of RPComA collateral flow. This suggests the presence of more extensive parenchymal collaterals from posterior cerebral arteries, from the vertebrobasilar circulation to the external carotid artery or other collaterals. Consequently, later abnormalities of vertebrobasilar flow might adversely affect right hemispheric function in this children

  14. Cerebral aspects of neonatal extracorporeal membrane oxygenation: a review.

    NARCIS (Netherlands)

    Mol, A.C. de; Liem, K.D.; Heijst, A.F.J. van

    2013-01-01

    Background: Neonatal extracorporeal membrane oxygenation (ECMO) is a lifesaving therapeutic approach in newborns suffering from severe, but potentially reversible, respiratory insufficiency, mostly complicated by neonatal persistent pulmonary hypertension. However, cerebral damage, intracerebral

  15. Processing of membranes for oxygenation using the Bellhouse-effect

    Directory of Open Access Journals (Sweden)

    Neußer C.

    2015-09-01

    Full Text Available State-of-the-art lung support systems are limited to short time application because of a lack of long term hemocompatibility and protein absorption on the membrane surfaces. In a highly interdisciplinary project at RWTH Aachen University a biohybrid lung assist system with endothelialised gas exchange flat membranes is developed to improve long term compatibility of oxygenators. To increase the gas exchange performance of flat membranes hollows are imprinted in the membrane surfaces. This approach is based on the research of B. J. Bell-house et al. [1], who discovered this effect, now known as Bellhouse-effect, around 1960. In this paper a processes to manufacture membrane assemblies for oxygenation with imprinted hollows on the flat membrane surfaces is reviewed.

  16. Steel reinforced composite silicone membranes and its integration to microfluidic oxygenators for high performance gas exchange.

    Science.gov (United States)

    Matharoo, Harpreet; Dabaghi, Mohammadhossein; Rochow, Niels; Fusch, Gerhard; Saraei, Neda; Tauhiduzzaman, Mohammed; Veldhuis, Stephen; Brash, John; Fusch, Christoph; Selvaganapathy, P Ravi

    2018-01-01

    Respiratory distress syndrome (RDS) is one of the main causes of fatality in newborn infants, particularly in neonates with low birth-weight. Commercial extracorporeal oxygenators have been used for low-birth-weight neonates in neonatal intensive care units. However, these oxygenators require high blood volumes to prime. In the last decade, microfluidics oxygenators using enriched oxygen have been developed for this purpose. Some of these oxygenators use thin polydimethylsiloxane (PDMS) membranes to facilitate gas exchange between the blood flowing in the microchannels and the ambient air outside. However, PDMS is elastic and the thin membranes exhibit significant deformation and delamination under pressure which alters the architecture of the devices causing poor oxygenation or device failure. Therefore, an alternate membrane with high stability, low deformation under pressure, and high gas exchange was desired. In this paper, we present a novel composite membrane consisting of an ultra-thin stainless-steel mesh embedded in PDMS, designed specifically for a microfluidic single oxygenator unit (SOU). In comparison to homogeneous PDMS membranes, this composite membrane demonstrated high stability, low deformation under pressure, and high gas exchange. In addition, a new design for oxygenator with sloping profile and tapered inlet configuration has been introduced to achieve the same gas exchange at lower pressure drops. SOUs were tested by bovine blood to evaluate gas exchange properties. Among all tested SOUs, the flat design SOU with composite membrane has the highest oxygen exchange of 40.32 ml/min m 2 . The superior performance of the new device with composite membrane was demonstrated by constructing a lung assist device (LAD) with a low priming volume of 10 ml. The LAD was achieved by the oxygen uptake of 0.48-0.90 ml/min and the CO 2 release of 1.05-2.27 ml/min at blood flow rates ranging between 8 and 48 ml/min. This LAD was shown to increase the

  17. Simulation and experiment for oxygen-enriched combustion engine using liquid oxygen to solidify CO2

    Science.gov (United States)

    Liu, Yongfeng; Jia, Xiaoshe; Pei, Pucheng; Lu, Yong; Yi, Li; Shi, Yan

    2016-01-01

    For capturing and recycling of CO2 in the internal combustion engine, Rankle cycle engine can reduce the exhaust pollutants effectively under the condition of ensuring the engine thermal efficiency by using the techniques of spraying water in the cylinder and optimizing the ignition advance angle. However, due to the water spray nozzle need to be installed on the cylinder, which increases the cylinder head design difficulty and makes the combustion conditions become more complicated. In this paper, a new method is presented to carry out the closing inlet and exhaust system for internal combustion engines. The proposed new method uses liquid oxygen to solidify part of cooled CO2 from exhaust system into dry ice and the liquid oxygen turns into gas oxygen which is sent to inlet system. The other part of CO2 is sent to inlet system and mixed with oxygen, which can reduce the oxygen-enriched combustion detonation tendency and make combustion stable. Computing grid of the IP52FMI single-cylinder four-stroke gasoline-engine is established according to the actual shape of the combustion chamber using KIVA-3V program. The effects of exhaust gas recirculation (EGR) rate are analyzed on the temperatures, the pressures and the instantaneous heat release rates when the EGR rate is more than 8%. The possibility of enclosing intake and exhaust system for engine is verified. The carbon dioxide trapping device is designed and the IP52FMI engine is transformed and the CO2 capture experiment is carried out. The experimental results show that when the EGR rate is 36% for the optimum EGR rate. When the liquid oxygen of 35.80-437.40 g is imported into the device and last 1-20 min, respectively, 21.50-701.30 g dry ice is obtained. This research proposes a new design method which can capture CO2 for vehicular internal combustion engine.

  18. Heat-induced reorganization of the structure of photosystem II membranes: role of oxygen evolving complex.

    Science.gov (United States)

    Busheva, Mira; Tzonova, Iren; Stoitchkova, Katerina; Andreeva, Atanaska

    2012-12-05

    The sensitivity of the green plants' photosystem II (PSII) to high temperatures is investigated in PSII enriched membranes and in membranes, from which the oxygen evolving complex is removed. Using steady-state 77 K fluorescence and resonance Raman spectroscopy we analyze the interdependency between the temperature-driven changes in structure and energy distribution in the PSII supercomplex. The results show that the heat treatment induces different reduction of the 77 K fluorescence emission in both types of investigated membranes: (i) an additional considerable decrease of the overall fluorescence emission in Tris-washed membranes as compared to the native membranes; (ii) a transition point at 42°C(,) observed only in native membranes; (iii) a sharp reduction of the PSII core fluorescence in Tris-washed membranes at temperatures higher than 50°C; (iv) a 3 nm red-shift of F700 band's maximum in Tris-washed membranes already at 20°C and its further shift by 1 nm at temperature increase. Both treatments intensified their action by increasing the aggregation and dissociation of the peripheral light harvesting complexes. The oxygen-evolving complex, in addition to its main function to produce O(2), increases the thermal stability of PSII core by strengthening the connection between the core and the peripheral antenna proteins and by keeping their structural integrity. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Silicon Micropore-Based Parallel Plate Membrane Oxygenator.

    Science.gov (United States)

    Dharia, Ajay; Abada, Emily; Feinberg, Benjamin; Yeager, Torin; Moses, Willieford; Park, Jaehyun; Blaha, Charles; Wright, Nathan; Padilla, Benjamin; Roy, Shuvo

    2018-02-01

    Extracorporeal membrane oxygenation (ECMO) is a life support system that circulates the blood through an oxygenating system to temporarily (days to months) support heart or lung function during cardiopulmonary failure until organ recovery or replacement. Currently, the need for high levels of systemic anticoagulation and the risk for bleeding are main drawbacks of ECMO that can be addressed with a redesigned ECMO system. Our lab has developed an approach using microelectromechanical systems (MEMS) fabrication techniques to create novel gas exchange membranes consisting of a rigid silicon micropore membrane (SμM) support structure bonded to a thin film of gas-permeable polydimethylsiloxane (PDMS). This study details the fabrication process to create silicon membranes with highly uniform micropores that have a high level of pattern fidelity. The oxygen transport across these membranes was tested in a simple water-based bench-top set-up as well in a porcine in vivo model. It was determined that the mass transfer coefficient for the system using SµM-PDMS membranes was 3.03 ± 0.42 mL O 2 min -1 m -2 cm Hg -1 with pure water and 1.71 ± 1.03 mL O 2 min -1 m -2 cm Hg -1 with blood. An analytic model to predict gas transport was developed using data from the bench-top experiments and validated with in vivo testing. This was a proof of concept study showing adequate oxygen transport across a parallel plate SµM-PDMS membrane when used as a membrane oxygenator. This work establishes the tools and the equipoise to develop future generations of silicon micropore membrane oxygenators. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Development of a Novel Intravenous Membrane Oxygenator

    National Research Council Canada - National Science Library

    Heinrich, Shelly

    1997-01-01

    .... The current IMO device consists of several hundred hollow fiber membranes (H:FMs) manifolded to gas supply lines for O2 delivery, CO2 removal, and helium supply to a balloon integer located within the fiber bundle...

  1. Influence of oxygen enrichment on compression ignition engines using biodiesel blends

    Directory of Open Access Journals (Sweden)

    Vaiyapuri Senthil Murugan

    2017-01-01

    Full Text Available The influence of oxygen enrichment on performance and emission characteristics of a single cylinder diesel engine operated with biodiesel blends have been investigated in this work. The methyl ester of jatropha biodiesel was selected as bio-diesel and four blends (B10, B20, B30, and B40 were selected for experimental investigations. The performance and emission characteristics were obtained for the these blends along with three oxygen enrichment flow rates (1, 3, and 5 L per minute using an oxygen cylinder at the air intake in the diesel engine. The performance and emission characteristics were studied and compared with the diesel and biodiesel. It was observed that, oxygen enrichment enhances the brake thermal efficiency, HC, CO, and smoke. B10 biodiesel with 5 L per minute oxygen enrichment was found to be the best fuel for biodiesel operation.

  2. Surface oxygen vacancy and oxygen permeation flux limits of perovskite ion transport membranes

    KAUST Repository

    Hunt, Anton; Dimitrakopoulos, Georgios; Ghoniem, Ahmed F.

    2015-01-01

    © 2015 Elsevier B.V. The mechanisms and quantitative models for how oxygen is separated from air using ion transport membranes (ITMs) are not well understood, largely due to the experimental complexity for determining surface exchange reactions

  3. Effect of oxygen enrichment in air on acid gas combustion under Claus conditions

    KAUST Repository

    Ibrahim, Salisu

    2013-09-01

    Results are presented to examine the combustion of acid gas (H2S and CO2) in hydrogen-fueled flames using a mixture of oxygen and nitrogen under Claus conditions (Φ = 3). Specifically the effect of oxygen enrichment in the above flames is examined. The compositions of acid gas examined are100% H2S and 50% H2S/50% CO2 with different percentages of oxygen enrichment (0%, 19.3% and 69.3%) in the oxygen/nitrogen mixtures. The results revealed that combustion of acid gas formed SO2 wherein the mole fraction of SO2 increased to an asymptotic value at all the oxygen concentrations examined. In addition, increase in oxygen enrichment of the air resulted in increased amounts of SO2 rather than the formation of more desirable elemental sulfur. In case of 50% H2S/50% CO2 acid gas, carbon monoxide mole fraction increased with oxygen enrichment which is an indicator to the availability of additional amounts of oxygen into the reaction pool. This gas mixture resulted in the formation of other sulfurous–carbonaceous compounds (COS and CS2) due to the presence of carbon monoxide. The results showed that the rate of COS formation increased with oxygen enrichment due to the availability of higher amounts of CO while that of CS2 reduced. The global reactions responsible for this observed phenomenon are presented.

  4. Dense pulmonary opacification in neonates treated with extracorporeal membrane oxygenation

    Energy Technology Data Exchange (ETDEWEB)

    Schlesinger, A.E.; Cornish, J.D.; Null, D.M.

    1986-09-01

    Chest radiographic findings in three neonates with respiratory failure secondary to meconium aspiration treated with extracorporeal membrane oxygenation (ECMO) are described. The degree of pulmonary opacification on the chest radiographs failed to correlate with the patients' clinical status as measured by the arterial oxygen levels but correlated well with the peak airway pressure (PAP) and continuous positive airway pressure (CPAP) settings on the mechanical ventilator. Because a variable portion of the arterial blood oxygenation is performed by the extracorporeal membrane oxygenator and unusually large fluctuations in airway pressure settings can occur in these patients while on ECMO, it is important to realize that the chest radiography may not be an accurate predictor of the patients' clinical status.

  5. Dense pulmonary opacification in neonates treated with extracorporeal membrane oxygenation

    International Nuclear Information System (INIS)

    Schlesinger, A.E.; Cornish, J.D.; Null, D.M.

    1986-01-01

    Chest radiographic findings in three neonates with respiratory failure secondary to meconium aspiration treated with extracorporeal membrane oxygenation (ECMO) are described. The degree of pulmonary opacification on the chest radiographs failed to correlate with the patients' clinical status as measured by the arterial oxygen levels but correlated well with the peak airway pressure (PAP) and continuous positive airway pressure (CPAP) settings on the mechanical ventilator. Because a variable portion of the arterial blood oxygenation is performed by the extracorporeal membrane oxygenator and unusually large fluctuations in airway pressure settings can occur in these patients while on ECMO, it is important to realize that the chest radiography may not be an accurate predictor of the patients' clinical status. (orig.)

  6. Cupriavidus pauculus bacteremia in a child on extracorporeal membrane oxygenation.

    Science.gov (United States)

    Uzodi, Adaora S; Schears, Gregory J; Neal, James R; Henry, Nancy K

    2014-01-01

    We report a case of bacteremia secondary to Cupriavidus pauculus in a 15-month-old boy on extracorporeal membrane oxygenation (ECMO). The source of the organism was water in the thermoregulator reservoir. The child responded well to cefepime and ciprofloxacin, a delayed oxygenator change out and replacement of the thermoregulator reservoir with a unit that was cleaned and decontaminated with sodium hypochlorite. Isolation of Cupriavidus pauculus from a patient on ECMO support should raise suspicion of the reservoir as a source.

  7. Monitoring of the Adult Patient on Venoarterial Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Mabel Chung

    2014-01-01

    Full Text Available Venoarterial extracorporeal membrane oxygenation (VA ECMO provides mechanical support to the patient with cardiac or cardiopulmonary failure. This paper reviews the physiology of VA ECMO including the determinants of ECMO flow and gas exchange. The efficacy of this therapy may be determined by assessing patient hemodynamics and device flow, overall gas exchange support, markers of adequate oxygen delivery, and pulsatility of the arterial blood pressure waveform.

  8. Prospects and problems of dense oxygen permeable membranes

    DEFF Research Database (Denmark)

    Hendriksen, P.V.; Larsen, P.H.; Mogensen, Mogens Bjerg

    2000-01-01

    The prospects of using mixed ionic/electronic conducting ceramics for syngas production in a catalytic membrane reactor are analysed. Problems relating to limited thermodynamic stability and poor dimensional stability of candidate materials are addressed, The consequences for these problems......, of flux improving measures like minimization of membrane thickness and minimization of the losses due to oxygen exchange over the membrane surfaces, are discussed. The analysis is conducted on two candidate materials: La0.6Sr0.4Co0.2Fe0.8O3-delta and SrFeCo0.5Ox. Finally. experimental investigations...

  9. High Temperature Oxidation of Steel in an Oxygen-enriched Low NOX Furnace Environment

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, D.; Grandmaison, E.W. [Department of Chemical Engineering, Queen' s University, Kingston, ON K7L 3N6 (Canada); Matovic, M.D. [Department of Mechanical and Materials Engineering, Queen' s University, Kingston, ON K7L 3N6 (Canada); Barnes, K.R. [KB Technical Services, Inc (formerly) Stelco Inc, Research Manager, Stelco Inc., P.O. Box 2030, Hamilton, ON L8N 3T1 (Canada); Nelson, B.D. [Department of Chemical Engineering, Senior Researcher, Dofasco Inc., P.O. Box 2460, Hamilton, ON L8N 3J5 (Canada)

    2006-09-15

    Steel scaling tests have been performed in a research furnace utilizing an oxygen-enriched, low NOX, burner. This work was performed in conjunction with a study of the combustion characteristics for the Canadian Gas Research Institute (CGRI) low NOX burner. The furnace (a facility of the Centre for Advanced Gas Combustion Technology (CAGCT)) was fired with the burner mounted in a sidewall configuration similar to the geometry encountered in steel reheat furnaces. Scale habit, intactness, adhesion and oxidation rates were examined for five grades of steel over a range of stack oxygen concentrations ({approx}0.8% - {approx}4.3%) and oxygen enrichment levels (0-90%) at 1100C. Steel grade had the largest effect on scaling properties examined in this work. Within the tests for each grade, stack oxygen concentration had the largest effect on the scaling properties while oxygen enrichment level had only a small effect.

  10. Development of thin film inorganic membranes for oxygen separation

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Hyo Jeong

    2012-08-22

    Membrane-based gas separation systems are noteworthy among technological options for carbon capture and storage (CCS), which is an important strategy to reduce CO{sub 2} emitted from point sources, e.g. mainly fossil power plants. In Oxyfuel-Combustion and Pre-Combustion of CCS power plant concepts oxygen separation from air is required. To meet this requirement oxygen transport membranes (OTM) consisting of gastight mixed ionic electronic conductors (MIEC) are proposed, which are associated with significantly lower efficiency losses compared with conventional air separation technologies. For cost effective application a maximum oxygen flux has to be achieved to reduce the membrane area. This can be met by reduction of membrane thickness. Therefore, the reduction of the membrane thickness to the micrometer range or even below is aimed in the present thesis. Ce{sub 0.8}Gd{sub 0.2}O{sub 2-{delta}} (CGO) with fluorite crystal structure and La{sub 0.58}Sr{sub 0.4}Co{sub 0.2}Fe{sub 0.8}O{sub 3-{delta}} (LSCF) with perovskite crystal structure were developed as thin film membrane. CGO is expected to be more stable than other potential MIEC membranes in reducing atmospheres and to achieve sufficient oxygen permeation, e.g. in syngas production or petrol chemistry. LSCF is expected to be highly permeable with an acceptable chemical stability in Oxyfuel-combustion. Various porous ceramic substrates were prepared by vacuum-slip-casting and warm-pressing, and then characterized for porosity, gas-permeability and surface roughness. Subsequently, two approaches to fabrication of thin film membranes were investigated, which are wetchemical deposition (WCD) and physical vapor deposition (PVD). For WCD, nano-dispersions and colloidal sols were prepared for membrane top-layer and/or interlayer. When CGO nano-dispersion (NDCGO) was spin-coated as thin film membrane, the gastightness of sintered membranes was increased with decrease in spinning time and increase in concentration of

  11. Nosocomial transmission of Cupriavidus pauculus during extracorporeal membrane oxygenation.

    Science.gov (United States)

    Stovall, S H; Wisdom, C; McKamie, W; Ware, W; Dedman, H; Fiser, R T

    2010-01-01

    Patients undergoing extracorporeal membrane oxygenation (ECMO) are at increased risk of infection. We present the first known report of nosocomial infection with Cupriavidus pauculus attributable to contamination from ECMO equipment and describe the measures taken to halt subsequent infections. A cluster of infections in ECMO patients should prompt team members to consider contamination of equipment with environmental pathogens as a possible cause.

  12. Extracorporeal membrane oxygenation after intravenous injection of paraffin oil

    DEFF Research Database (Denmark)

    Pasgaard, Thomas; Huynh, Anh-Nhi Thi; Gjedsted, Jakob

    2016-01-01

    We present a rare cause of acute respiratory distress syndrome (ARDS) due to an accidental intravascular injection of paraffin oil. While there is no specific therapy, we decided to support the patient with veno-venous extracorporeal membrane oxygenation (V-V ECMO) to allow the ARDS to resolve. A...

  13. A route for oxygen isotope enrichment of α-COOH groups in amino acids

    International Nuclear Information System (INIS)

    Steinschneidner, A.; St Armour, T.; Valentine, B.; Burgar, M.I.; Fiat, D.

    1981-01-01

    Oxygen-17 was introduced into leucine, proline, phenylalanine and tyrosine. The corresponding tert-butyloxycarbonyl amino acids were first converted to their O-methyl esters. Following saponification with Na 17 OH, the tert-butyloxycarbonyl group was removed to yield free amino acid enriched with oxygen-17 by approximately 1000-fold. Oxygen-17 NMR revealed well-resolved peaks for the labelled amino acids. The chemical shifts are reported. (author)

  14. Numeric Simulation of Oxygen Enriched Combustion in a Frit Melting Kiln

    Directory of Open Access Journals (Sweden)

    Bernardo A. Herrera-Múnera

    2013-11-01

    Full Text Available In this paper, a numerical study of air enriched combustion on a natural gas rotary furnace for frita melting is presented. This study was done with the aim of determining an oxygen concentration to ensure economic feasibility of the process without affecting quality requirements. The simulations were conducted using the commercial software ANSYS FLUENT as a design tool to predict the behavior of the thermal system and to establish operations conditions with different oxygen enrichment levels. Finite Rate / Eddy Dissipation model was used for combustion simulation, while k - ε Realizable and Discrete Ordinates models were utilized for turbulence and radiation simulation, respectively. It was found that an enrichment level close to 31% of oxygen in the air allows for reaching temperatures for frita melting larger than 1700 K. In this way, current consumption of high purity oxygen can be diminished without affecting the production levels and the quality of the product.

  15. Development of thin film oxygen transport membranes on metallic supports

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Ye

    2012-04-25

    Asymmetric membrane structure has an attractive potential in the application of O{sub 2}/N{sub 2} gas separation membrane for the future membrane-based fossil fuel power plant using oxyfuel technology, which will reduce the carbon dioxide emission. The aim of this study is the development of a metal supported multi-layer membrane structure with a thin film top membrane layer and porous ceramic interlayers. Four perovskite materials were studied as candidate membrane materials. Material properties of these perovskite materials were investigated and compared. La{sub 0.58}Sr{sub 0.4}Co{sub 0.2}Fe{sub 0.8}O{sub 3-{delta}} (LSCF58428) showed sufficient oxygen permeability, an acceptable thermal expansion coefficient and a moderate sintering temperature. Alternatively, Ba{sub 0.5}Sr{sub 0.5}Co{sub 0.8}Fe{sub 0.2}O{sub 3-{delta}} (BSCF5582) is considered obtaining very high oxygen permeability but a higher thermal expansion and a lower thermal stability than LSCF58428. Four different Ni-based alloys were studied as candidate substrate materials in the asymmetric membrane structure. The chromia-scale alloys (Hastelloy X, Inconel 600 and Haynes 214) caused Cr poisoning of the membrane layer material LSCF58428 during high-temperature co-firing in air. NiCoCrAlY with a high Al content (12.7 wt%) was found to be the most promising substrate material. It showed a good chemical compatibility with perovskite materials at high temperatures. In order to bridge the highly porous substrate and the thin top membrane layer interlayers were developed. Two interlayers were coated by screen printing on the porous NiCoCrAlY substrate which was sintered at 1225 C in flowing H{sub 2} atmosphere. Screen printing pastes were optimized by investigating various solvent and binder combinations and various ceramic powder contents. The first interlayer significantly improved the surface quality and the surface pore size has been reduced from 30-50{mu}m on the substrate to few {mu}m on the first

  16. Nano-Enriched and Autonomous Sensing Framework for Dissolved Oxygen

    Directory of Open Access Journals (Sweden)

    Nader Shehata

    2015-08-01

    Full Text Available This paper investigates a nano-enhanced wireless sensing framework for dissolved oxygen (DO. The system integrates a nanosensor that employs cerium oxide (ceria nanoparticles to monitor the concentration of DO in aqueous media via optical fluorescence quenching. We propose a comprehensive sensing framework with the nanosensor equipped with a digital interface where the sensor output is digitized and dispatched wirelessly to a trustworthy data collection and analysis framework for consolidation and information extraction. The proposed system collects and processes the sensor readings to provide clear indications about the current or the anticipated dissolved oxygen levels in the aqueous media.

  17. Nano-Enriched and Autonomous Sensing Framework for Dissolved Oxygen.

    Science.gov (United States)

    Shehata, Nader; Azab, Mohammed; Kandas, Ishac; Meehan, Kathleen

    2015-08-14

    This paper investigates a nano-enhanced wireless sensing framework for dissolved oxygen (DO). The system integrates a nanosensor that employs cerium oxide (ceria) nanoparticles to monitor the concentration of DO in aqueous media via optical fluorescence quenching. We propose a comprehensive sensing framework with the nanosensor equipped with a digital interface where the sensor output is digitized and dispatched wirelessly to a trustworthy data collection and analysis framework for consolidation and information extraction. The proposed system collects and processes the sensor readings to provide clear indications about the current or the anticipated dissolved oxygen levels in the aqueous media.

  18. Prolonged Extracorporeal Membrane Oxygenation Support for Acute Respiratory Distress Syndrome

    Directory of Open Access Journals (Sweden)

    Wen-Je Ko

    2006-01-01

    Full Text Available When all conventional treatments for respiratory failure in patients with acute respiratory distress syndrome (ARDS have failed, extracorporeal membrane oxygenation (ECMO can provide a chance of survival in these desperately ill patients. A 49-year-old male patient developed septic shock and progressive ARDS after liver abscess drainage. Venovenous ECMO was given due to refractory respiratory failure on postoperative day 6. Initially, two heparin-binding hollow-fiber microporous membrane oxygenators in parallel were used in the ECMO circuit. Twenty-two oxygenators were changed in the first 22 days of ECMO support because of plasma leak in the oxygenators. Each oxygenator had an average life of 48 hours. Thereafter, a single silicone membrane oxygenator was used in the ECMO circuit, which did not require change during the remaining 596 hours of ECMO. The patient's tidal volume was only 90 mL in the nadir and less than 300 mL for 26 days during the ECMO course. The patient required ECMO support for 48 days and survived despite complications, including septic shock, ARDS, acute renal failure, drug-induced leukopenia, and multiple internal bleeding. This patient received an unusually long duration of ECMO support. However, he survived, recovered well, and was in New York Heart Association functional class I-II, with a forced expiratory volume in 1 second of 81% of the predicted level 18 months later. In conclusion, ECMO can provide a chance of survival for patients with refractory ARDS. The reversibility of lung function is possible in ARDS patients regardless of the severity of lung dysfunction at the time of treatment.

  19. Dual phase oxygen transport membrane for efficient oxyfuel combustion

    International Nuclear Information System (INIS)

    Ramasamy, Madhumidha

    2016-01-01

    Oxygen transport membranes (OTMs) are attracting great interest for the separation of oxygen from air in an energy efficient way. A variety of solid oxide ceramic materials that possess mixed ionic and electronic conductivity (MIEC) are being investigated for efficient oxygen separation (Betz '10, Skinner '03). Unfortunately these materials do not exhibit high degradation stability under harsh ambient conditions such as flue gas containing CO_2, SO_x, H_2O and dust, pressure gradients and high temperatures that are typical in fossil fuel power plants. For this reason, dual phase composite membranes are developed to combine the best characteristics of different compounds to achieve high oxygen permeability and sufficient chemical and mechanical stability at elevated temperatures. In this thesis, the dual phase membrane Ce_0_._8Gd_0_._2O_2_-_δ - FeCo_2O_4 (CGO-FCO) was developed after systematic investigation of various combinations of ionic and electronic conductors. The phase distribution of the composite was investigated in detail using electron microscopes and this analysis revealed the phase interaction leading to grain boundary rock salt phase and formation of perovskite secondary phase. A systematic study explored the onset of phase interactions to form perovskite phase and the role of this unintended phase as pure electronic conductor was identified. Additionally optimization of conventional sintering process to eliminate spinel phase decomposition into rock salt was identified. An elaborate study on the absolute minimum electronic conductor requirement for efficient percolation network was carried out and its influence on oxygen flux value was measured. Oxygen permeation measurements in the temperature range of 600 C - 1000 C under partial pressure gradient provided by air and argon as feed and sweep gases are used to identify limiting transport processes. The dual phase membranes are much more prone to surface exchange limitations because of the limited

  20. Dual phase oxygen transport membrane for efficient oxyfuel combustion

    Energy Technology Data Exchange (ETDEWEB)

    Ramasamy, Madhumidha

    2016-07-01

    Oxygen transport membranes (OTMs) are attracting great interest for the separation of oxygen from air in an energy efficient way. A variety of solid oxide ceramic materials that possess mixed ionic and electronic conductivity (MIEC) are being investigated for efficient oxygen separation (Betz '10, Skinner '03). Unfortunately these materials do not exhibit high degradation stability under harsh ambient conditions such as flue gas containing CO{sub 2}, SO{sub x}, H{sub 2}O and dust, pressure gradients and high temperatures that are typical in fossil fuel power plants. For this reason, dual phase composite membranes are developed to combine the best characteristics of different compounds to achieve high oxygen permeability and sufficient chemical and mechanical stability at elevated temperatures. In this thesis, the dual phase membrane Ce{sub 0.8}Gd{sub 0.2}O{sub 2-δ} - FeCo{sub 2}O{sub 4} (CGO-FCO) was developed after systematic investigation of various combinations of ionic and electronic conductors. The phase distribution of the composite was investigated in detail using electron microscopes and this analysis revealed the phase interaction leading to grain boundary rock salt phase and formation of perovskite secondary phase. A systematic study explored the onset of phase interactions to form perovskite phase and the role of this unintended phase as pure electronic conductor was identified. Additionally optimization of conventional sintering process to eliminate spinel phase decomposition into rock salt was identified. An elaborate study on the absolute minimum electronic conductor requirement for efficient percolation network was carried out and its influence on oxygen flux value was measured. Oxygen permeation measurements in the temperature range of 600 C - 1000 C under partial pressure gradient provided by air and argon as feed and sweep gases are used to identify limiting transport processes. The dual phase membranes are much more prone to surface

  1. Severe myocardial injury and extracorporeal membrane oxygenation following perinatal asphyxia

    Directory of Open Access Journals (Sweden)

    P. Benson Ham

    2015-05-01

    Full Text Available Perinatal asphyxia is a common cause of morbidity and mortality in the newborn and is associated with myocardial injury in a significant proportion of cases. Biomarkers, echocardiography, and rhythm disturbances are sensitive indicators of myocardial ischemia and may predict mortality. We present a case of severe myocardial dysfunction immediately after delivery managed with extracorporeal membrane oxygenation (ECMO and discuss the role of cardiac biomarkers, echocardiography, electrocardiography, and ECMO in the asphyxiated newborn.

  2. Technical-and-Economic Efficiency of Draft Enriched with Oxygen in Small-Capacity Heating Boilers

    Directory of Open Access Journals (Sweden)

    P. Ratnikov

    2013-01-01

    Full Text Available Data on complex experimental and theoretical investigations pertaining to efficiency of oxygen-enriched draft in the small-capacity heating boilers as exemplified by the plant HEIZA (HW-S-10/K have been presented in the paper. The paper provides a calculation model of heating processes in heat generator burner (as exemplified by HEIZA plant. Simulation of heating processes in the operational zone has been executed in paper. The experimental data have proved model adequacy. The calculation scheme of the plant will be used in future for determination of power and ecological efficiency of draft enrichment with oxygen.

  3. Study on Characteristics of Co-firing Ammonia/Methane Fuels under Oxygen Enriched Combustion Conditions

    Science.gov (United States)

    Xiao, Hua; Wang, Zhaolin; Valera-Medina, Agustin; Bowen, Philip J.

    2018-06-01

    Having a background of utilising ammonia as an alternative fuel for power generation, exploring the feasibility of co-firing ammonia with methane is proposed to use ammonia to substitute conventional natural gas. However, improvement of the combustion of such fuels can be achieved using conditions that enable an increase of oxygenation, thus fomenting the combustion process of a slower reactive molecule as ammonia. Therefore, the present study looks at oxygen enriched combustion technologies, a proposed concept to improve the performance of ammonia/methane combustion. To investigate the characteristics of ammonia/methane combustion under oxygen enriched conditions, adiabatic burning velocity and burner stabilized laminar flame emissions were studied. Simulation results show that the oxygen enriched method can help to significantly enhance the propagation of ammonia/methane combustion without changing the emission level, which would be quite promising for the design of systems using this fuel for practical applications. Furthermore, to produce low computational-cost flame chemistry for detailed numerical analyses for future combustion studies, three reduced combustion mechanisms of the well-known Konnov's mechanism were compared in ammonia/methane flame simulations under practical gas turbine combustor conditions. Results show that the reduced reaction mechanisms can provide good results for further analyses of oxygen enriched combustion of ammonia/methane. The results obtained in this study also allow gas turbine designers and modellers to choose the most suitable mechanism for further combustion studies and development.

  4. An Elementary Overview of the Selection of Materials for Service in Oxygen-Enriched Environments

    Science.gov (United States)

    Davis, Samuel Eddie

    2012-01-01

    The process for selecting materials for use in oxygen or oxygen-enriched environments is one that continues to be investigated by many industries due to the importance to those industries of oxygen systems. There are several excellent resources available to assist oxygen systems design engineers and end-users, with the most comprehensive being ASTM MNL-36, Safe Use of Oxygen and Oxygen Systems: Handbook for Design, Operation and Maintenance, 2nd Edition. ASTM also makes available several standards for oxygen systems. However, the ASTM publications are extremely detailed, and typically designed for professionals who already possess a working knowledge of oxygen systems. No notable resource exists, whether an ASTM or other organizational publication, which can be used to educate engineers or technicians who have no prior knowledge of the nuances of oxygen system design and safety. This paper will fill the void for information needed by organizations that design or operate oxygen systems. The information in this paper is not new information, but is a concise and easily understood summary of selecting materials for oxygen systems. This paper will serve well as an employee s first introduction to oxygen system materials selection, and probably the employee s first introduction to ASTM.

  5. Effects of oxygen enriched combustion on pollution and performance characteristics of a diesel engine

    Directory of Open Access Journals (Sweden)

    P. Baskar

    2016-03-01

    Full Text Available Oxygen enriched combustion is one of the attractive combustion technologies to control pollution and improve combustion in diesel engines. An experimental test was conducted on a single cylinder direct injection diesel engine to study the impact of oxygen enrichment on pollution and performance parameters by increasing the oxygen concentration of intake air from 21 to 27% by volume. The tests results show that the combustion process was improved as there is an increase in thermal efficiency of 4 to 8 percent and decrease in brake specific fuel consumption of 5 to 12 percent. There is also a substantial decrease in unburned hydro carbon, carbon mono-oxide and smoke density levels to the maximum of 40, 55 and 60 percent respectively. However, there is a considerable increase in nitrogen oxide emissions due to increased combustion temperature and extra oxygen available which needs to be addressed.

  6. Characterization and quantitation of concanavalin A binding by plasma membrane enriched fractions from soybean root

    International Nuclear Information System (INIS)

    Berkowitz, R.L.; Travis, R.L.

    1981-01-01

    The binding of concanavalin A (Con A) to soybean root membranes in plasma membrane enriched fractions (recovered from the 34/45% interface of simplified discontinuous sucrose density gradients) was studied using a radiochemical assay employing tritated ( 3 H)-Con A. The effect of lectin concentration, time, and membrane protein concentration on the specific binding of 3 H-Con A by the membranes was evaluated. Kinetic analyses showed that Con A will react with membranes in that fraction in a characteristic and predictable manner. The parameters for an optimal and standard binding assay were established. Maximal binding occurred with Con A concentrations in the range of 8 to 16% of the total membrane protein with incubation times greater than 40 min at 22 C. Approximately 10 15 molecules of 3 H-Con A were bound per microgram of membrane protein at saturation. Binding was reversible. Greater than 92% of the total Con A bound at saturation was released by addition of α-methyl mannoside. A major peak of 3 H-Con A binding was also observed in fractions recovered from the 25/30% interface of a complex discontinuous sucrose density gradient when membranes were isolated in the absence of Mg 2+ . When high Mg 2+ was present in the isolation and gradient media, the peak was shifted to a fraction recovered from the 34/38% sucrose interface. These results suggest that Con A binding sites are also present on membranes of the endoplasmic reticulum. The amount of Con A bound by endoplasmic reticulum membranes was at least twice the amount bound by membranes in plasma membrane enriched fractions when binding was compared on a per unit membrane protein basis. In contrast, mitochondrial inner membranes, which equilibrate at the same density as plasma membranes, had little ability to bind the lectin

  7. Oxygen transport by oxygen potential gradient in dense ceramic oxide membranes

    Energy Technology Data Exchange (ETDEWEB)

    Maiya, P.S.; Balachandran, U.; Dusek, J.T.; Mieville, R.L. [Argonne National Lab., IL (United States). Energy Technology Div.; Kleefisch, M.S.; Udovich, C.A. [Amoco Exploration/Production, Naperville, IL (United States)

    1996-05-01

    Numerous studies have been conducted in recent years on the partial oxidation of methane to synthesis gas (syngas: CO + H{sub 2}) with air as the oxidant. In partial oxidation, a mixed-oxide ceramic membrane selectively transports oxygen from the air; this transport is driven by the oxygen potential gradient. Of the several ceramic materials the authors have tested, a mixed oxide based on the Sr-Fe-Co-O system has been found to be very attractive. Extensive oxygen permeability data have been obtained for this material in methane conversion experiments carried out in a reactor. The data have been analyzed by a transport equation based on the phenomenological theory of diffusion under oxygen potential gradients. Thermodynamic calculations were used to estimate the driving force for the transport of oxygen ions. The results show that the transport equation deduced from the literature describes the permeability data reasonably well and can be used to determine the diffusion coefficients and the associated activation energy of oxygen ions in the ceramic membrane material.

  8. Examinations of the process of hard coal and biomass blend combustion in OEA (oxygen enriched atmosphere)

    International Nuclear Information System (INIS)

    Pawlak-Kruczek, Halina; Ostrycharczyk, Michał; Czerep, Michał; Baranowski, Marcin; Zgóra, Jacek

    2015-01-01

    The benefits of oxygen enrichment have been demonstrated in a variety of industrial combustion applications, but to date no implementation of oxygen enrichment in boilers has been reported, primarily due to their already high thermal efficiencies and a very large scale of such systems, which require significant amounts of oxygen. But recently, oxygen combustion in boilers has become one of the CCS technologies which can be an effective tool for reducing greenhouse gases emissions, and oxygen enriched combustion is suitable for low-calorific fuels, including biomass. This paper analyses the use of oxygen enrichment in a furnace for co-firing of different kinds of biomass with hard coal in terms of emission and burnout impact (LOI). As a part of this research, the effect of injection oxygen mode and total oxygen concentration on the flue gas emission (SO_2, NO_x) and burnout from co-firing of straw and wooden biomass in different proportions (20% and 40%) with hard coal were studied. The co-firing tests were carried out in an isothermal flow reactor. One of the benefits from the OEA (oxygen enriched atmosphere) technology is more effective separation of CO_2 owing to the higher CO_2 concentration in the flue gas. The additional advantage of the OEA combustion technology in comparison with oxy-fuel combustion is that the OEA process needs lower O_2 purities and therefore it is cost-effective. Experimental tests on co-firing of 20% straw-hard coal blend were conducted in oxygen enriched (up to 25 and 30%) atmospheres with three variants of O_2 injection modes. NO_x, SO_2 emissions and burnout for the various atmospheres in the combustion chamber were studied. Moreover, co-firing tests were performed with 40% share of wooden biomass to examine the effect of the biomass share and a type on emission of NO_x and SO_2 in OEA. The two O_2 injection modes were investigated. In each case, the emission of SO_2 increases alongside an increase of oxygen concentration in

  9. Dietary free fatty acids form alkaline phosphatase-enriched microdomains in the intestinal brush border membrane

    DEFF Research Database (Denmark)

    Hansen, Gert H; Rasmussen, Karina; Niels-Christiansen, Lise-Lotte

    2011-01-01

    this membrane passage in organ cultured intestinal mucosal explants. We found that in addition to a rapid uptake into the cytoplasm, a fraction of the fatty acid analogs were inserted directly into the brush border membrane. Furthermore, a brief exposure of microvillar membrane vesicles to a fat mixture...... mimicking a physiological solution of dietary mixed micelles, rearranged the lipid raft microdomain organization of the membranes. Thus, the fat mixture generated a low-density subpopulation of microvillar detergent resistant membranes (DRMs) highly enriched in alkaline phosphatase (AP). Since this GPI-linked...... enzyme is the membrane protein in the brush border with the highest affinity for lipid rafts, this implies that free fatty acids selectively insert stably into these membrane microdomains. We have previously shown that absorption of dietary lipids transiently induce a selective endocytosis of AP from...

  10. Thermogravimetric analysis of rice and wheat straw catalytic combustion in air- and oxygen-enriched atmospheres

    International Nuclear Information System (INIS)

    Yu Zhaosheng; Ma Xiaoqian; Liu Ao

    2009-01-01

    By thermogravimetric analysis (TGA) study, the influences of different catalysts on the ignition and combustion of rice and wheat straw in air- and oxygen-enriched atmospheres have been investigated in this paper. Straw combustion is divided into two stages. One is the emission and combustion of volatiles and the second is the combustion of fixed carbon. The existence of catalysts in the first step enhances the emission of volatiles from the straw. The action of catalysts in the second step of straw combustion may be as a carrier of oxygen to the fixed carbon. Two parameters have been used to compare the characteristics of ignition and combustion of straw under different catalysts and in various oxygen concentrations. One is the temperature when the conversion degree combustible (CDC) of straw is 5%, the other is the CDC when the temperature is 900 deg. C. By comparing the different values of the two parameters, the different influences of the catalysts and oxygen concentration on the ignition and combustion of straw have been studied, the action of these catalysts for straw ignition and combustion in air and oxygen-enriched atmosphere is effective except the oxygen-enriched catalytic combustion of wheat straw fixed carbon

  11. Improving Hemocompatibility of Membranes for Extracorporeal Membrane Oxygenators by Grafting Nonthrombogenic Polymer Brushes.

    Science.gov (United States)

    Obstals, Fabian; Vorobii, Mariia; Riedel, Tomáš; de Los Santos Pereira, Andres; Bruns, Michael; Singh, Smriti; Rodriguez-Emmenegger, Cesar

    2018-03-01

    Nonthrombogenic modifications of membranes for extracorporeal membrane oxygenators (ECMOs) are of key interest. The absence of hemocompatibility of these membranes and the need of anticoagulation of patients result in severe and potentially life-threatening complications during ECMO treatment. To address the lack of hemocompatibility of the membrane, surface modifications are developed, which act as barriers to protein adsorption on the membrane and, in this way, prevent activation of the coagulation cascade. The modifications are based on nonionic and zwitterionic polymer brushes grafted directly from poly(4-methyl-1-pentene) (TPX) membranes via single electron transfer-living radical polymerization. Notably, this work introduces the first example of well-controlled surface-initiated radical polymerization of zwitterionic brushes. The antifouling layers markedly increase the recalcification time (a proxy of initiation of coagulation) compared to bare TPX membranes. Furthermore, platelet and leukocyte adhesion is drastically decreased, rendering the ECMO membranes hemocompatible. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. 99 Tc NMR determination of the oxygen isotope content in 18 O-enriched water.

    Science.gov (United States)

    Tarasov, Valerii P; Kirakosyan, Gayana А; German, Konstantin E

    2018-03-01

    99 Tc NMR has been suggested as an original method of evaluating the content of oxygen isotopes in oxygen-18-enriched water, a precursor for the production of radioisotope fluorine-18 used in positron emission tomography. To this end, solutions of NH 4 TcO 4 or NaTcO 4 (up to 0.28 mol/L) with natural abundance of oxygen isotopes in virgin or recycled 18 O-enriched water have been studied by 99 Tc NMR. The method is based on 16 O/ 17 O/ 18 O intrinsic isotope effects in the 99 Tc NMR chemical shifts, and the statistical distribution of oxygen isotopes in the coordination sphere of TcO 4 - and makes it possible to quantify the composition of enriched water by measuring the relative intensities of the 99 Tc NMR signals of the Tc 16 O 4-n 18 O n - isotopologues. Because the oxygen exchange between TcO 4 - and enriched water in neutral and alkaline solutions is characterized by slow kinetics, gaseous HCl was bubbled through a solution for a few seconds to achieve the equilibrium distribution of oxygen isotopes in the Tc coordination sphere without distortion of the oxygen composition of the water. Pertechnetate ion was selected as a probe due to its high stability in solutions and the significant 99 Tc NMR shift induced by a single 16 O→ 18 O substitution (-0.43 ± 0.01 ppm) in TcO 4 - and spin coupling constant 1 J( 99 Tc- 17 O) (131.46 Hz) favourable for the observation of individual signals of Tc 16 O 4-n 18 O n - isotopologues. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Extracorporeal Membrane Oxygenation for Adult Community-Acquired Pneumonia: Outcomes and Predictors of Mortality.

    Science.gov (United States)

    Ramanathan, Kollengode; Tan, Chuen Seng; Rycus, Peter; MacLaren, Graeme

    2017-05-01

    Extracorporeal membrane oxygenation is a rescue therapy used to support severe cardiorespiratory failure. Data on outcomes from severe community-acquired pneumonia in adults receiving rescue extracorporeal membrane oxygenation are mainly confined to single-center experiences or specific pathogens. We examined data from the Extracorporeal Life Support Organisation registry to identify risk factors for poor outcomes in adult patients with community-acquired pneumonia. Retrospective data analysis. Extracorporeal Life Support Organization Registry database. We collected deidentified data on adult patients (> 18 yr) receiving extracorporeal membrane oxygenation for community-acquired pneumonia between 2002 and 2012. Patients with incomplete data or brain death were excluded. The primary outcome measure was in-hospital mortality. Other measurements included demographic information, pre-extracorporeal membrane oxygenation mechanical ventilation and biochemical variables, inotrope requirements, extracorporeal membrane oxygenation mode, duration, and complications. Initial univariate analysis assessed potential associations between survival and various pre-extracorporeal membrane oxygenation and extracorporeal membrane oxygenation factors. Variables with p values of less than 0.1 were considered for logistic regression analysis to identify predictors of mortality. None. One thousand fifty-five patients, who satisfied inclusion criteria, were included in the final analysis. There was an increase in the number of patients cannulated per annum over the 10-year period studied. Univariate analysis identified pre-extracorporeal membrane oxygenation and extracorporeal membrane oxygenation variables associated with high mortality. Further multiple regression analysis identified certain pre-extracorporeal membrane oxygenation factors as predictors of mortality, including duration of mechanical ventilation prior to extracorporeal membrane oxygenation, lower arterial pressure, fungal

  14. Constraining the Final Fates of Massive Stars by Oxygen and Iron Enrichment History in the Galaxy

    Science.gov (United States)

    Suzuki, Akihiro; Maeda, Keiichi

    2018-01-01

    Recent observational studies of core-collapse supernovae suggest that only stars with zero-age main-sequence masses smaller than 16–18 {M}ȯ explode when they are red supergiants, producing Type IIP supernovae. This may imply that more massive stars produce other types of supernovae or they simply collapse to black holes without giving rise to bright supernovae. This failed supernova hypothesis can lead to significantly inefficient oxygen production because oxygen abundantly produced in inner layers of massive stars with zero-age main-sequence masses around 20–30 {M}ȯ might not be ejected into the surrounding interstellar space. We first assume an unspecified population of oxygen injection events related to massive stars and obtain a model-independent constraint on how much oxygen should be released in a single event and how frequently such events should happen. We further carry out one-box galactic chemical enrichment calculations with different mass ranges of massive stars exploding as core-collapse supernovae. Our results suggest that the model assuming that all massive stars with 9–100 {M}ȯ explode as core-collapse supernovae is still most appropriate in explaining the solar abundances of oxygen and iron and their enrichment history in the Galaxy. The oxygen mass in the Galaxy is not explained when assuming that only massive stars with zero-age main-sequence masses in the range of 9–17 {M}ȯ contribute to the galactic oxygen enrichment. This finding implies that a good fraction of stars more massive than 17 {M}ȯ should eject their oxygen layers in either supernova explosions or some other mass-loss processes.

  15. Extracorporeal membrane oxygenation: current clinical practice, coding, and reimbursement.

    Science.gov (United States)

    Schuerer, Douglas J E; Kolovos, Nikoleta S; Boyd, Kayla V; Coopersmith, Craig M

    2008-07-01

    Extracorporeal membrane oxygenation (ECMO) is a technique for providing life support for patients experiencing both pulmonary and cardiac failure by maintaining oxygenation and perfusion until native organ function is restored. ECMO is used routinely at many specialized hospitals for infants and less commonly for children with respiratory or cardiac failure from a variety of causes. Its usage is more controversial in adults, but select medical centers have reported favorable findings in patients with ARDS and other causes of severe pulmonary failure. ECMO is also rarely used as a rescue therapy in a small subset of adult patients with cardiac failure. This article will review the current uses and techniques of ECMO in the critical care setting as well as the evidence supporting its usage. In addition, current practice management related to coding and reimbursement for this intensive therapy will be discussed.

  16. Technological advances in extracorporeal membrane oxygenation for respiratory failure.

    Science.gov (United States)

    Rehder, Kyle J; Turner, David A; Bonadonna, Desiree; Walczak, Richard J; Rudder, Robert J; Cheifetz, Ira M

    2012-08-01

    Extracorporeal membrane oxygenation (ECMO) for neonatal and pediatric cardiac and/or respiratory failure is well established, and its use for adult respiratory failure is rapidly increasing. Management strategies developed over the past 30 years coupled with significant recent technological advances have led to improved ECMO survival. These new technologies are expanding the potential applications for ECMO in exciting ways, including new patient populations and the ability to make ECMO mobile for both intra- and inter-hospital transport. In this article, we highlight some of the recent technological advances and their impact on the utilization of ECMO in increasingly diverse patient populations.

  17. Laser photochemical studies on di-isopropyl ether for oxygen-18 enrichment

    International Nuclear Information System (INIS)

    Mathi, P.; Kumar, Awadhesh; Ghosh, Ayan; Nayak, A.K.; Parthasarathy, V.; Nataraju, V.; Jadhav, K.A.; Babu, K.Rajendra; Sarkar, S.K.

    2013-05-01

    Oxygen-18 is needed for the production of Fluorine-18 in medical cyclotron for use in positron emission tomography. This report deals with our work on Oxygen-18 selective photo dissociation of natural di-isopropyl ether under various conditions leading to various oxygen bearing products having different levels of 18 O enrichment. Apart from obtaining 18 O enrichment in products 2-propanol and acetaldehyde, we have observed unusually high enrichment (about 39%) in another photoproduct, acetone, as measured by mass spectrometry. This new finding is attributed to 18 O selective secondary reaction channels which is supported by molecular orbital calculations. The investigation required characterization and quantitative estimation of various chemical species, viz., di-isopropyl ether, acetaldehyde, acetone and isopropanol by various instrumental methods of analysis. These methods include gas chromatography, Fourier transform infrared spectrometry and quadrupole mass spectrometry. Detailed Gas Chromatographic (GC) studies summarize the interference problems encountered for quantitatively identifying different photo-products and establish the right experimental conditions for optimum separation. This exercise is extremely useful for an isotope enrichment scheme as it generates a valuable database to understand the processes involved for both selectivity enhancement and degradation. (author)

  18. Extracorporeal membrane oxygenation: experience in an adult medical ICU.

    Science.gov (United States)

    Hermans, G; Meersseman, W; Wilmer, A; Meyns, B; Bobbaers, H

    2007-06-01

    Extracorporeal membrane oxygenation (ECMO) is a technology that can provide extracorporeal gas exchange to patients with severe pulmonary or cardiac dysfunction. We report on our clinical experience with ECMO in critically ill patients. We performed a retrospective analysis of 23 patients treated with ECMO in a medical intensive care unit in a tertiary referral academic centre. 13 patients were considered immunocompetent and 10 were immunocompromised when extracorporeal membrane oxygenation was started. 16 patients presented with acute respiratory distress syndrome (ARDS), 2 patients had intractable cardiac failure, and 5 patients had combined respiratory and cardiac failure. In 16 patients, a veno-venous bypass was constructed; in 7 patients, the initial bypass was venoarterial. 11 patients survived. In 2 patients technical complications were fatal. Our data indicate that patients with community-acquired pneumonia and no underlying disease will benefit most from this technique. However, long-term survival is possible in immunocompromised patients. Venoarterial bypass can carry a higher risk for technical complications. Increasing experience apparently also reduces the risk of technical complications.

  19. From nitrogen enrichment to oxygen depletion: a mechanistic model of coastal marine ecosystems response

    DEFF Research Database (Denmark)

    Cosme, Nuno Miguel Dias; Koski, Marja; Hauschild, Michael Zwicky

    Nitrogen (N) emissions from anthropogenic sources may enrich coastal waters and lead to marine eutrophication impacts. Processes describing N-limited primary production (PP), zooplankton grazing, and bacterial respiration of sinking organic carbon, were modelled to quantify the potential dissolved...... oxygen (DO) consumption as a function of N input. Such indicator is the basis for an eXposure Factor (XF) applied in Life Cycle Impact Assessment (LCIA) to estimate impacts from N enrichment. The Large Marine Ecosystems (LME) biogeographical classification system was adopted to address the spatial...

  20. Oxygen permeation and thermo-chemical stability of oxygen separation membrane materials for the oxyfuel process

    Energy Technology Data Exchange (ETDEWEB)

    Ellett, Anna Judith

    2009-07-01

    The reduction of CO{sub 2} emissions, generally held to be one of the most significant contributors to global warming, is a major technological issue. CO{sub 2} Capture and Storage (CCS) techniques applied to large stationary sources such as coal-fired power plants could efficiently contribute to the global carbon mitigation effort. The oxyfuel process, which consists in the burning of coal in an oxygen-rich atmosphere to produce a flue gas highly concentrated in CO{sub 2}, is a technology considered for zero CO{sub 2} emission coal-fired power plants. The production of this O{sub 2}-rich combustion gas from air can be carried out using high purity oxygen separation membranes. Some of the most promising materials for this application are mixed ionic-electronic conducting (MIEC) materials with perovskite and K{sub 2}NiF{sub 4} perovskite-related structures. The present work examines the selection of La{sub 0.58}Sr{sub 0.4}Co{sub 0.2}Fe{sub 0.8}O{sub 3-{delta}} (LSCF58), La{sub 2}NiO{sub 4+{delta}}, Pr{sub 0.58}Sr{sub 0.4}Co{sub 0.2}Fe{sub 0.8}O{sub 3-{delta}} (PSCF58) and Ba{sub 0.5}Sr{sub 0.5}Co{sub 0.8}Fe{sub 0.2}O{sub 3-{delta}} (BSCF50) as membrane materials for the separation of O{sub 2} and N{sub 2} in the framework of the oxyfuel process with flue gas recycling. Annealing experiments were carried out on pellets exposed to CO{sub 2}, water vapour, O{sub 2} and Cr{sub 2}O{sub 3} in order to determine the thermo-chemical resistance to the atmospheres and the high temperature conditions present during membrane operation in a coal-fired power plant. The degradation of their microstructure was investigated using Scanning Electron Microscopy (SEM) in combination with electron dispersive spectroscopy (EDS) as well as X-Ray Diffraction (XRD). Also, the oxygen permeation fluxes of selected membranes were investigated as a function of temperature. The membrane materials selected were characterised using thermo-analytical techniques such as precision thermogravimetric

  1. Surface monofunctionalized polymethyl pentene hollow fiber membranes by plasma treatment and hemocompatibility modification for membrane oxygenators

    Science.gov (United States)

    Huang, Xin; Wang, Weiping; Zheng, Zhi; Fan, Wenling; Mao, Chun; Shi, Jialiang; Li, Lei

    2016-01-01

    The hemocompatibility of polymethyl pentene (PMP) hollow fiber membranes (HFMs) was improved through surface modification for membrane oxygenator applications. The modification was performed stepwise with the following: (1) oxygen plasma treatment, (2) functionalization of monosort hydroxyl groups through NaBH4 reduction, and (3) grafting 2-methacryloyloxyethyl phosphorylcholine (MPC) or heparin. SEM, ATR-FTIR, and XPS analyses were conducted to confirm successful grafting during the modification. The hemocompatibility of PMP HFMs was analyzed and compared through protein adsorption, platelet adhesion, and coagulation tests. Pure CO2 and O2 permeation rates, as well as in vitro gas exchange rates, were determined to evaluate the mass transfer properties of PMP HFMs. SEM results showed that different nanofibril topographies were introduced on the HFM surface. ATR-FTIR and XPS spectra indicated the presence of functionalization of monosort hydroxyl group and the grafting of MPC and heparin. Hemocompatibility evaluation results showed that the modified PMP HFMs presented optimal hemocompatibility compared with pristine HFMs. Gas permeation results revealed that gas permeation flux increased in the modified HFMs because of dense surface etching during the plasma treatment. The results of in vitro gas exchange rates showed that all modified PMP HFMs presented decreased gas exchange rates because of potential surface fluid wetting. The proposed strategy exhibits a potential for fabricating membrane oxygenators for biomedical applications to prevent coagulation formation and alter plasma-induced surface topology and composition.

  2. Tetraspanin-enriched microdomains: a functional unit in cell plasma membranes.

    Science.gov (United States)

    Yáñez-Mó, María; Barreiro, Olga; Gordon-Alonso, Mónica; Sala-Valdés, Mónica; Sánchez-Madrid, Francisco

    2009-09-01

    Membrane lipids and proteins are non-randomly distributed and are unable to diffuse freely in the plane of the membrane. This is because of multiple constraints imposed both by the cortical cytoskeleton and by the preference of lipids and proteins to cluster into diverse and specialized membrane domains, including tetraspanin-enriched microdomains, glycosylphosphatidyl inositol-linked proteins nanodomains and caveolae, among others. Recent biophysical characterization of tetraspanin-enriched microdomains suggests that they might be specially suited for the regulation of avidity of adhesion receptors and the compartmentalization of enzymatic activities. Moreover, modulation by tetraspanins of the function of adhesion receptors involved in inflammation, lymphocyte activation, cancer and pathogen infection suggests potential as therapeutic targets. This review explores this emerging picture of tetraspanin microdomains and discusses the implications for cell adhesion, proteolysis and pathogenesis.

  3. Proteomic characterization of golgi membranes enriched from Arabidopsis suspension cell cultures

    DEFF Research Database (Denmark)

    Hansen, Sara Fasmer; Ebert, Berit; Rautengarten, Carsten

    2016-01-01

    The plant Golgi apparatus has a central role in the secretory pathway and is the principal site within the cell for the assembly and processing of macromolecules. The stacked membrane structure of the Golgi apparatus along with its interactions with the cytoskeleton and endoplasmic reticulum has...... historically made the isolation and purification of this organelle difficult. Density centrifugation has typically been used to enrich Golgi membranes from plant microsomal preparations, and aside from minor adaptations, the approach is still widely employed. Here we outline the enrichment of Golgi membranes...... from an Arabidopsis cell suspension culture that can be used to investigate the proteome of this organelle. We also provide a useful workflow for the examination of proteomic data as the result of multiple analyses. Finally, we highlight a simple technique to validate the subcellular localization...

  4. Oxygen transport membrane system and method for transferring heat to catalytic/process reactors

    Science.gov (United States)

    Kelly, Sean M; Kromer, Brian R; Litwin, Michael M; Rosen, Lee J; Christie, Gervase Maxwell; Wilson, Jamie R; Kosowski, Lawrence W; Robinson, Charles

    2014-01-07

    A method and apparatus for producing heat used in a synthesis gas production is provided. The disclosed method and apparatus include a plurality of tubular oxygen transport membrane elements adapted to separate oxygen from an oxygen containing stream contacting the retentate side of the membrane elements. The permeated oxygen is combusted with a hydrogen containing synthesis gas stream contacting the permeate side of the tubular oxygen transport membrane elements thereby generating a reaction product stream and radiant heat. The present method and apparatus also includes at least one catalytic reactor containing a catalyst to promote the stream reforming reaction wherein the catalytic reactor is surrounded by the plurality of tubular oxygen transport membrane elements. The view factor between the catalytic reactor and the plurality of tubular oxygen transport membrane elements radiating heat to the catalytic reactor is greater than or equal to 0.5.

  5. Oxygen transport membrane system and method for transferring heat to catalytic/process reactors

    Science.gov (United States)

    Kelly, Sean M.; Kromer, Brian R.; Litwin, Michael M.; Rosen, Lee J.; Christie, Gervase Maxwell; Wilson, Jamie R.; Kosowski, Lawrence W.; Robinson, Charles

    2016-01-19

    A method and apparatus for producing heat used in a synthesis gas production process is provided. The disclosed method and apparatus include a plurality of tubular oxygen transport membrane elements adapted to separate oxygen from an oxygen containing stream contacting the retentate side of the membrane elements. The permeated oxygen is combusted with a hydrogen containing synthesis gas stream contacting the permeate side of the tubular oxygen transport membrane elements thereby generating a reaction product stream and radiant heat. The present method and apparatus also includes at least one catalytic reactor containing a catalyst to promote the steam reforming reaction wherein the catalytic reactor is surrounded by the plurality of tubular oxygen transport membrane elements. The view factor between the catalytic reactor and the plurality of tubular oxygen transport membrane elements radiating heat to the catalytic reactor is greater than or equal to 0.5

  6. Test Operation of Oxygen-Enriched Incinerator for Wastes From Nuclear Fuel Fabrication Facility

    International Nuclear Information System (INIS)

    Kim, J.-G.; Yang, H.cC.; Park, G.-I.; Kim, I.-T.; Kim, J.-K.

    2002-01-01

    The oxygen-enriched combustion concept, which can minimize off-gas production, has been applied to the incineration of combustible uranium-containing wastes from a nuclear fuel fabrication facility. A simulation for oxygen combustion shows the off-gas production can be reduced by a factor of 6.7 theoretically, compared with conventional air combustion. The laboratory-scale oxygen enriched incineration (OEI) process with a thermal capacity of 350 MJ/h is composed of an oxygen feeding and control system, a combustion chamber, a quencher, a ceramic filter, an induced draft fan, a condenser, a stack, an off-gas recycle path, and a measurement and control system. Test burning with cleaning paper and office paper in this OEI process shows that the thermal capacity is about 320 MJ/h, 90 % of design value and the off-gas reduces by a factor of 3.5, compared with air combustion. The CO concentration for oxygen combustion is lower than that of air combustion, while the O2 concentration in off-gas is kept above 25 vol % for a simple incineration process without any grate. The NOx concentration in an off-gas stream does not reduce significantly due to air incoming by leakage, and the volume and weight reduction factors are not changed significantly, which suggests a need for an improvement in sealing

  7. System and method for air temperature control in an oxygen transport membrane based reactor

    Science.gov (United States)

    Kelly, Sean M

    2016-09-27

    A system and method for air temperature control in an oxygen transport membrane based reactor is provided. The system and method involves introducing a specific quantity of cooling air or trim air in between stages in a multistage oxygen transport membrane based reactor or furnace to maintain generally consistent surface temperatures of the oxygen transport membrane elements and associated reactors. The associated reactors may include reforming reactors, boilers or process gas heaters.

  8. Astrocytic mitochondrial membrane hyperpolarization following extended oxygen and glucose deprivation.

    Directory of Open Access Journals (Sweden)

    Andrej Korenić

    Full Text Available Astrocytes can tolerate longer periods of oxygen and glucose deprivation (OGD as compared to neurons. The reasons for this reduced vulnerability are not well understood. Particularly, changes in mitochondrial membrane potential (Δψ(m in astrocytes, an indicator of the cellular redox state, have not been investigated during reperfusion after extended OGD exposure. Here, we subjected primary mouse astrocytes to glucose deprivation (GD, OGD and combinations of both conditions varying in duration and sequence. Changes in Δψ(m, visualized by change in the fluorescence of JC-1, were investigated within one hour after reconstitution of oxygen and glucose supply, intended to model in vivo reperfusion. In all experiments, astrocytes showed resilience to extended periods of OGD, which had little effect on Δψ(m during reperfusion, whereas GD caused a robust Δψ(m negativation. In case no Δψ(m negativation was observed after OGD, subsequent chemical oxygen deprivation (OD induced by sodium azide caused depolarization, which, however, was significantly delayed as compared to normoxic group. When GD preceded OD for 12 h, Δψ(m hyperpolarization was induced by both GD and subsequent OD, but significant interaction between these conditions was not detected. However, when GD was extended to 48 h preceding OGD, hyperpolarization enhanced during reperfusion. This implicates synergistic effects of both conditions in that sequence. These findings provide novel information regarding the role of the two main substrates of electron transport chain (glucose and oxygen and their hyperpolarizing effect on Δψ(m during substrate deprivation, thus shedding new light on mechanisms of astrocyte resilience to prolonged ischemic injury.

  9. Oxygen activation at the plasma membrane: relation between superoxide and hydroxyl radical production by isolated membranes.

    Science.gov (United States)

    Heyno, Eiri; Mary, Véronique; Schopfer, Peter; Krieger-Liszkay, Anja

    2011-07-01

    Production of reactive oxygen species (hydroxyl radicals, superoxide radicals and hydrogen peroxide) was studied using EPR spin-trapping techniques and specific dyes in isolated plasma membranes from the growing and the non-growing zones of hypocotyls and roots of etiolated soybean seedlings as well as coleoptiles and roots of etiolated maize seedlings. NAD(P)H mediated the production of superoxide in all plasma membrane samples. Hydroxyl radicals were only produced by the membranes of the hypocotyl growing zone when a Fenton catalyst (FeEDTA) was present. By contrast, in membranes from other parts of the seedlings a low rate of spontaneous hydroxyl radical formation was observed due to the presence of small amounts of tightly bound peroxidase. It is concluded that apoplastic hydroxyl radical generation depends fully, or for the most part, on peroxidase localized in the cell wall. In soybean plasma membranes from the growing zone of the hypocotyl pharmacological tests showed that the superoxide production could potentially be attributed to the action of at least two enzymes, an NADPH oxidase and, in the presence of menadione, a quinone reductase.

  10. Oxygen-transfer performance of a newly designed, very low-volume membrane oxygenator.

    Science.gov (United States)

    Burn, Felice; Ciocan, Sorin; Carmona, Natalia Mendez; Berner, Marion; Sourdon, Joevin; Carrel, Thierry P; Tevaearai Stahel, Hendrik T; Longnus, Sarah L

    2015-09-01

    Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Methods of staining and visualization of sphingolipid enriched and non-enriched plasma membrane regions of Arabidopsis thaliana with fluorescent dyes and lipid analogues

    Directory of Open Access Journals (Sweden)

    Blachutzik Jörg O

    2012-08-01

    Full Text Available Abstract Background Sterols and Sphingolipids form lipid clusters in the plasma membranes of cell types throughout the animal and plant kingdoms. These lipid domains provide a medium for protein signaling complexes at the plasma membrane and are also observed to be principal regions of membrane contact at the inception of infection. We visualized different specific fluorescent lipophilic stains of the both sphingolipid enriched and non-sphingolipid enriched regions in the plasma membranes of live protoplasts of Arabidopsis thaliana. Results Lipid staining protocols for several fluorescent lipid analogues in plants are presented. The most emphasis was placed on successful protocols for the single and dual staining of sphingolipid enriched regions and exclusion of sphingolipid enriched regions on the plasma membrane of Arabidopsis thaliana protoplasts. A secondary focus was placed to ensure that these staining protocols presented still maintain cell viability. Furthermore, the protocols were successfully tested with the spectrally sensitive dye Laurdan. Conclusion Almost all existing staining procedures of the plasma membrane with fluorescent lipid analogues are specified for animal cells and tissues. In order to develop lipid staining protocols for plants, procedures were established with critical steps for the plasma membrane staining of Arabidopsis leaf tissue and protoplasts. The success of the plasma membrane staining protocols was additionally verified by measurements of lipid dynamics by the fluorescence recovery after photobleaching technique and by the observation of new phenomena such as time dependent lipid polarization events in living protoplasts, for which a putative physiological relevance is suggested.

  12. Effect of Oxygen Enrichment in Propane Laminar Diffusion Flames under Microgravity and Earth Gravity Conditions

    Science.gov (United States)

    Bhatia, Pramod; Singh, Ravinder

    2017-06-01

    Diffusion flames are the most common type of flame which we see in our daily life such as candle flame and match-stick flame. Also, they are the most used flames in practical combustion system such as industrial burner (coal fired, gas fired or oil fired), diesel engines, gas turbines, and solid fuel rockets. In the present study, steady-state global chemistry calculations for 24 different flames were performed using an axisymmetric computational fluid dynamics code (UNICORN). Computation involved simulations of inverse and normal diffusion flames of propane in earth and microgravity condition with varying oxidizer compositions (21, 30, 50, 100 % O2, by mole, in N2). 2 cases were compared with the experimental result for validating the computational model. These flames were stabilized on a 5.5 mm diameter burner with 10 mm of burner length. The effect of oxygen enrichment and variation in gravity (earth gravity and microgravity) on shape and size of diffusion flames, flame temperature, flame velocity have been studied from the computational result obtained. Oxygen enrichment resulted in significant increase in flame temperature for both types of diffusion flames. Also, oxygen enrichment and gravity variation have significant effect on the flame configuration of normal diffusion flames in comparison with inverse diffusion flames. Microgravity normal diffusion flames are spherical in shape and much wider in comparison to earth gravity normal diffusion flames. In inverse diffusion flames, microgravity flames were wider than earth gravity flames. However, microgravity inverse flames were not spherical in shape.

  13. Quantification of Postmembrane Gaseous Microembolization During Venoarterial Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Jiao, York; Gipson, Keith E; Bonde, Pramod; Mangi, Abeel; Hagberg, Robert; Rosinski, David J; Gross, Jeffrey B; Schonberger, Robert B

    Prolonged use of venoarterial extracorporeal membrane oxygenation (VA ECMO) may be complicated by end-organ dysfunction. Although gaseous microemboli (GME) are thought to damage end organs during cardiopulmonary bypass, patient exposures to GME have not been well characterized during VA ECMO. We therefore performed an observational study of GME in adult VA ECMO patients, with correlation to clinical events during routine patient care. After institutional review board (IRB) approval, we used two Doppler probes to detect GME noninvasively in extracorporeal membrane oxygenation (ECMO) circuits on four patients for 15 hours total while also recording patient care events. We then conducted in vitro trials to compare Doppler signals with gold-standard measurements using an Emboli Detection and Classification EDAC quantifier (Luna Innnovations, Inc. Roanoke, VA) (Terumo Cardiovascular, Ann Arbor, MI) during simulated clinical interventions. Correlations between Doppler and EDAC data were used to estimate GME counts and volumes represented by clinical Doppler data. A total of 503 groups of Doppler peaks representing GME showers were observed, including 194 statistically larger showers during patient care activities containing 92% of total Doppler peaks. Intravenous injections accounted for an estimated 68% of GME and 88% of GME volume, whereas care involving movement accounted for an estimated 6% of GME and 3% of volume. Overall estimated embolic rates of 24,000 GME totaling 4 μl/hr rivals reported GME rates during cardiopulmonary bypass. Numerous GME are present in the postmembrane circuit during VA ECMO, raising concern for effects on microcirculation and organ dysfunction. Strategies to detect and minimize GME may be warranted to limit embolic exposures experienced by VA ECMO patients.

  14. A conceptual design of catalytic gasification fuel cell hybrid power plant with oxygen transfer membrane

    Science.gov (United States)

    Shi, Wangying; Han, Minfang

    2017-09-01

    A hybrid power generation system integrating catalytic gasification, solid oxide fuel cell (SOFC), oxygen transfer membrane (OTM) and gas turbine (GT) is established and system energy analysis is performed. In this work, the catalytic gasifier uses steam, recycled anode off-gas and pure oxygen from OTM system to gasify coal, and heated by hot cathode off-gas at the same time. A zero-dimension SOFC model is applied and verified by fitting experimental data. Thermodynamic analysis is performed to investigate the integrated system performance, and system sensitivities on anode off-gas back flow ratio, SOFC fuel utilization, temperature and pressure are discussed. Main conclusions are as follows: (1) System overall electricity efficiency reaches 60.7%(HHV) while the gasifier operates at 700 °C and SOFC at 850 °C with system pressure at 3.04 bar; (2) oxygen enriched combustion simplify the carbon-dioxide capture process, which derives CO2 of 99.2% purity, but results in a penalty of 6.7% on system electricity efficiency; (3) with SOFC fuel utilization or temperature increasing, the power output of SOFC increases while GT power output decreases, and increasing system pressure can improve both the performance of SOFC and GT.

  15. The effect of ultraviolet radiation on wheat root vesicles enriched in plasma membrane

    International Nuclear Information System (INIS)

    Wright, L.A. Jr.; Murphy, T.M.; Travis, R.L.

    1981-01-01

    The irradiation of plant cells with UV radiation (254 nm) causes various solutes to leak from the cells. Vesicles enriched in plasma membranes were prepared from wheat roots. These were used to determine whether UV radiation alters membrane function by direct action on the membranes and to distinguish between the chemical effects produced by high and low fluences of UV. The plasma membrane-associated K + -stimulated ATPase was very sensitive to UV radiation (100% inhibition with 2 ). ATPase activity measured in the absence of K + and K + -stimulated ATPase activity measured in the presence of diethylstilbestrol were much less sensitive. Lipid breakdown, as measured by malondialdehyde production, occurred only at UV fluences greater than 1.8 kJ/m 2 . (author)

  16. Hydrogen enrichment and separation from synthesis gas by the use of a membrane reactor

    International Nuclear Information System (INIS)

    Sanchez, J.M.; Barreiro, M.M.; Marono, M.

    2011-01-01

    One of the objectives of the CHRISGAS project was to study innovative gas separation and gas upgrading systems that have not been developed sufficiently yet to be tested at a demonstration scale within the time frame of the project, but which show some attractive merits and features for further development. In this framework CIEMAT studied, at bench scale, hydrogen enrichment and separation from syngas by the use of membranes and membrane catalytic reactors. In this paper results about hydrogen separation from synthesis gas by means of selective membranes are presented. Studies dealt with the evaluation of permeation and selectivity to hydrogen of prepared and pre-commercial Pd-based membranes. Whereas prepared membranes turned out to be non-selective, due to discontinuities of the palladium layer, studies conducted with the pre-commercial membrane showed that by means of a membrane reactor it is possible to completely separate hydrogen from the other gas components and produce pure hydrogen as a permeate stream, even in the case of complex reaction system (H 2 /CO/CO 2 /H 2 O) under WGS conditions gas mixtures. The advantages of using a water-gas shift membrane reactor (MR) over a traditional fixed bed reactor (TR) have also been studied. The experimental device included the pre-commercial Pd-based membrane and a commercial high temperature Fe-Cr-based, WGS catalyst, which was packed in the annulus between the membrane and the reactor outer shell. Results show that in the MR concept, removal of H 2 from the reaction side has a positive effect on WGS reaction, reaching higher CO conversion than in a traditional packed bed reactor at a given temperature. On increasing pressure on the reaction side permeation is enhanced and hence carbon monoxide conversion increases. -- Highlights: → H 2 enrichment and separation using a bench-scale membrane reactor MR is studied. → Permeation and selectivity to H 2 of Pd-based membranes was determined. → Complete separation

  17. Mechanical ventilation in patients subjected to extracorporeal membrane oxygenation (ECMO).

    Science.gov (United States)

    López Sanchez, M

    2017-11-01

    Mechanical ventilation (MV) is a crucial element in the management of acute respiratory distress syndrome (ARDS), because there is high level evidence that a low tidal volume of 6ml/kg (protective ventilation) improves survival. In these patients with refractory respiratory insufficiency, venovenous extracorporeal membrane oxygenation (ECMO) can be used. This salvage technique improves oxygenation, promotes CO 2 clearance, and facilitates protective and ultraprotective MV, potentially minimizing ventilation-induced lung injury. Although numerous trials have investigated different ventilation strategies in patients with ARDS, consensus is lacking on the optimal MV settings during venovenous ECMO. Although the concept of "lung rest" was introduced years ago, there are no evidence-based guidelines on its use in application to MV in patients supported by ECMO. How MV in ECMO patients can promote lung recovery and weaning from ventilation is not clear. The purpose of this review is to describe the ventilation strategies used during venovenous ECMO in clinical practice. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  18. Amine Enrichment of Thin-Film Composite Membranes via Low Pressure Plasma Polymerization for Antimicrobial Adhesion.

    Science.gov (United States)

    Reis, Rackel; Dumée, Ludovic F; He, Li; She, Fenghua; Orbell, John D; Winther-Jensen, Bjorn; Duke, Mikel C

    2015-07-15

    Thin-film composite membranes, primarily based on poly(amide) (PA) semipermeable materials, are nowadays the dominant technology used in pressure driven water desalination systems. Despite offering superior water permeation and salt selectivity, their surface properties, such as their charge and roughness, cannot be extensively tuned due to the intrinsic fabrication process of the membranes by interfacial polymerization. The alteration of these properties would lead to a better control of the materials surface zeta potential, which is critical to finely tune selectivity and enhance the membrane materials stability when exposed to complex industrial waste streams. Low pressure plasma was employed to introduce amine functionalities onto the PA surface of commercially available thin-film composite (TFC) membranes. Morphological changes after plasma polymerization were analyzed by SEM and AFM, and average surface roughness decreased by 29%. Amine enrichment provided isoelectric point changes from pH 3.7 to 5.2 for 5 to 15 min of plasma polymerization time. Synchrotron FTIR mappings of the amine-modified surface indicated the addition of a discrete 60 nm film to the PA layer. Furthermore, metal affinity was confirmed by the enhanced binding of silver to the modified surface, supported by an increased antimicrobial functionality with demonstrable elimination of E. coli growth. Essential salt rejection was shown minimally compromised for faster polymerization processes. Plasma polymerization is therefore a viable route to producing functional amine enriched thin-film composite PA membrane surfaces.

  19. Effectiveness of oxygen enriched hydrogen-HHO gas addition on DI diesel engine performance, emission and combustion characteristics

    Directory of Open Access Journals (Sweden)

    Premkartikkumar S.R.

    2014-01-01

    Full Text Available Nowadays, more researches focus on protecting the environment. Present investigation concern with the effectiveness of Oxygen Enriched hydrogen- HHO gas addition on performance, emission and combustion characteristics of a DI diesel engine. Here the Oxygen Enriched hydrogen-HHO gas was produced by the process of water electrolysis. When potential difference is applied across the anode and cathode electrodes of the electrolyzer, water is transmuted into Oxygen Enriched hydrogen-HHO gas. The produced gas was aspirated into the cylinder along with intake air at the flow rates of 1 lpm and 3.3 lpm. The results show that when Oxygen Enriched hydrogen-HHO gas was inducted, the brake thermal efficiency of the engine increased by 11.06%, Carbon monoxide decreased by 15.38%, Unburned hydrocarbon decreased by 18.18%, Carbon dioxide increased by 6.06%, however, the NOX emission increased by 11.19%.

  20. BLOOD COMPATIBILITY OF 2 DIFFERENT TYPES OF MEMBRANE-OXYGENATOR DURING CARDIOPULMONARY BYPASS IN INFANTS

    NARCIS (Netherlands)

    GU, YJ; BOONSTRA, PW; AKKERMAN, C; MUNGROOP, H; TIGCHELAAR, [No Value; VANOEVEREN, W

    1994-01-01

    The contact of blood with the artificial extracorporeal circuit causes a systemic inflammatory response due to blood activation. In this study, we compared two different paediatric membrane oxygenators used for extracorporeal circulation: a hollow fibre membrane oxygenator (Dideco Masterflo D-701,

  1. Oxygenation and hemodynamics in left and right cerebral hemispheres during induction of veno-arterial extracorporeal membrane oxygenation.

    NARCIS (Netherlands)

    Heyst, A.F.J. van; Liem, D.; Hopman, J.C.W.; Staak, F.H.J.M. van der; Sengers, R.C.A.

    2004-01-01

    OBJECTIVE: Oxygenation and hemodynamics in the left and right cerebral hemispheres were measured during induction of veno-arterial extracorporeal membrane oxygenation (VA-ECMO). STUDY DESIGN: Using near infrared spectrophotometry, effects of right common carotid artery (RCCA) and right internal

  2. Ductus arteriosus with left-to-right shunt during venoarterial extracorporeal membrane oxygenation: effects on cerebral oxygenation and hemodynamics.

    NARCIS (Netherlands)

    Heyst, A.F.J. van; Staak, F.H.J.M. van der; Hopman, J.C.W.; Tanke, R.B.; Sengers, R.C.A.; Liem, K.D.

    2003-01-01

    OBJECTIVE: To investigate the effect on cerebral oxygenation and hemodynamics of a patent ductus arteriosus with left-to-right shunt during venoarterial extracorporeal membrane oxygenation in a lamb model. DESIGN: Prospective intervention study in animals. SETTING: Animal research laboratory of a

  3. Textural properties of chars as determined by petrographic analysis: comparison between air-blown, oxygen-blown and oxygen-enriched gasification

    CSIR Research Space (South Africa)

    Oboirien, BO

    2012-11-01

    Full Text Available In this study, the textural properties of chars generated from a vitrinite, high ash coal in a fluidised bed gasifier under air-blown, oxygen-blown and oxygen-enriched conditions were determined by detailed petrographic analysis. The char samples...

  4. The effect of temperature and pressure on the oxygen reduction reactions in polyelectrolyte membranes

    Energy Technology Data Exchange (ETDEWEB)

    Holdcroft, S.; Abdou, M.S.; Beattie, P.; Basura, V. [Simon Fraser Univ., Burnaby, BC (Canada). Dept. of Chemistry

    1997-12-31

    The effect of temperature and pressure on the oxygen reduction reaction in polyelectrolyte membranes was described. Polyelectrolytes chosen for the experiment differed in composition, weight and flexibility of the polymer chains. The study was conducted in a solid state electrochemical cell at temperatures between 30 and 95 degrees C and in the pressure range of 1 to 5 atm. The solubility of oxygen in these membranes was found to follow Henry`s Law, while the diffusion coefficient decreased with pressure. The effect of temperature on the solubility of oxygen and the diffusion coefficient of oxygen in the membranes was similar to that observed in solution electrolytes. 2 refs., 3 figs.

  5. Monoolein lipid phases as incorporation and enrichment materials for membrane protein crystallization.

    Directory of Open Access Journals (Sweden)

    Ellen Wallace

    Full Text Available The crystallization of membrane proteins in amphiphile-rich materials such as lipidic cubic phases is an established methodology in many structural biology laboratories. The standard procedure employed with this methodology requires the generation of a highly viscous lipidic material by mixing lipid, for instance monoolein, with a solution of the detergent solubilized membrane protein. This preparation is often carried out with specialized mixing tools that allow handling of the highly viscous materials while minimizing dead volume to save precious membrane protein sample. The processes that occur during the initial mixing of the lipid with the membrane protein are not well understood. Here we show that the formation of the lipidic phases and the incorporation of the membrane protein into such materials can be separated experimentally. Specifically, we have investigated the effect of different initial monoolein-based lipid phase states on the crystallization behavior of the colored photosynthetic reaction center from Rhodobacter sphaeroides. We find that the detergent solubilized photosynthetic reaction center spontaneously inserts into and concentrates in the lipid matrix without any mixing, and that the initial lipid material phase state is irrelevant for productive crystallization. A substantial in-situ enrichment of the membrane protein to concentration levels that are otherwise unobtainable occurs in a thin layer on the surface of the lipidic material. These results have important practical applications and hence we suggest a simplified protocol for membrane protein crystallization within amphiphile rich materials, eliminating any specialized mixing tools to prepare crystallization experiments within lipidic cubic phases. Furthermore, by virtue of sampling a membrane protein concentration gradient within a single crystallization experiment, this crystallization technique is more robust and increases the efficiency of identifying productive

  6. Oxygen-enriched fermentation of sodium gluconate by Aspergillus niger and its impact on intracellular metabolic flux distributions.

    Science.gov (United States)

    Shen, Yuting; Tian, Xiwei; Zhao, Wei; Hang, Haifeng; Chu, Ju

    2018-01-01

    Different concentrations of oxygen-enriched air were utilized for sodium gluconate (SG) fermentation by Aspergillus niger. The fermentation time shortened from 20 to 15.5 h due to the increase of volumetric oxygen transfer coefficient (K L a) and the formation of more dispersed mycelia when inlet oxygen concentration ascended from 21 to 32%. According to metabolic flux analysis, during the growth phase, extracellular glucose for SG synthesis accounted for 79.0 and 85.3% with air and oxygen-enriched air (25%), respectively, whereas the proportions were 89.4 and 93.0% in the stationary phase. Intracellular glucose consumption decreased in oxygen-enriched fermentation, as cell respiration was more high-efficiently performed. Metabolic profiling indicated that most intermediates in TCA cycle and EMP pathway had smaller pool sizes in oxygen-enriched fermentations. Moreover, the main by-product of citric acid dramatically decreased from 1.36 to 0.34 g L -1 in oxygen-enriched fermentation. And the sodium gluconate yield increased from 0.856 to 0.903 mol mol -1 .

  7. The use of oxygen-enriched air for biomass gasification: initial scoping study

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-07-01

    The article reports an initial scoping study which is aimed at assessing the potential impact of using non-cryogenic oxygen, or oxygen-enriched air, for biomass gasification with respect to cost, design and operation of stationary biomass-fuelled generators in the range 5 to 15 MW(e). The study is expected to lead to identification of options worthy of more detailed study. The format of the scoping study is as follows: (i) using data on performance and cost from the manufacturers, minimum cost-saving potential is assessed; (ii) the performance and component costs of various gasifier types and engine types are reviewed to identify possible savings in monetary cost; (iii) an assessment of the likely impact of low-cost fuels is made and (iv) areas for detailed investigation are highlighted.

  8. Continuous Renal Replacement Therapy Applications on Extracorporeal Membrane Oxygenation Circuit.

    Science.gov (United States)

    Yetimakman, Ayse Filiz; Tanyildiz, Murat; Kesici, Selman; Kockuzu, Esra; Bayrakci, Benan

    2017-06-01

    Continuous venovenous hemofiltration or hemodiafiltration is used frequently in pediatric patients, but experience of continuous renal replacement therapy (CRRT) application on extracorporeal membrane oxygenation (ECMO) circuit is still limited. Among several methods used for applying CRRT on ECMO patients, we aim to share our experience on inclusion of a CRRT device in the ECMO circuit which we believe is easier and safer to apply. The data were collected on demographics, outcomes, and details of the treatment of ECMO patients who had CRRT. During the study period of 3 years, venous cannula of ECMO circuit before pump was used for CRRT access for both the filter inlet and outlet of CRRT machine to minimize the thromboembolic complications. The common indication for CRRT was fluid overload. CRRT was used in 3.68% of a total number of patients admitted and 43% of patients on ECMO. The patients have undergone renal replacement therapy for periods of time ranging between 24 h and 25 days (260 h mean). The survival rate of this group of patients with multiorgan failure was 33%. Renal recovery occurred in all of the survivors. Complications such as electrolyte imbalance, hypothermia, and bradykinin syndrome were easily managed. Adding a CRRT device on ECMO circuit is a safe and effective technique. The major advantages of this technique are easy to access, applying CRRT without extra anticoagulation process, preventing potential hemodynamic disturbances, and increased clearance of solutes and fluid overload using larger hemofilter.

  9. Extracorporeal membrane oxygenation for the treatment of postcardiotomy shock.

    Science.gov (United States)

    Whitman, Glenn J R

    2017-01-01

    Use of extracorporeal membrane oxygenation (ECMO), one of an increasing variety of mechanical circulatory support strategies, was first used close to 50 years ago. For decades, it was mostly applied to the pediatric population. However, during the past several years, its use has dramatically increased as therapy for pulmonary and cardiac failure in the adult. In particular, ECMO is being used more and more for postcardiotomy shock. Unfortunately, despite its increased application in this setting, improved outcomes have been hard to come by. Improved results must be grounded on an approach that honors the tenets of myocardial recovery, minimizing the work done by the heart during the recovery period. Left ventricular decompression should be a tenet of ECMO support in the setting of postcardiotomy shock, universally applied if we are to see any significant improvement in our results. Furthermore, the point is made that surgeons should play a leadership role in the immediate counseling of patients' families to assure realistic expectations on their part. To address the need for family support during this very difficult time, ECMO centers should design a programmatic approach to care for patients and their families so as to provide them with education, guidance, and emotional support. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  10. Blood Transfusion Strategies in Patients Undergoing Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Hyoung Soo Kim

    2017-02-01

    Full Text Available Extracorporeal membrane oxygenation (ECMO is frequently associated with bleeding and coagulopathy complications, which may lead to the need for transfusion of multiple blood products. However, blood transfusions are known to increase morbidity and mortality, as well as hospital cost, in critically ill patients. In current practice, patients on ECMO receive a transfusion, on average, of 1-5 packed red blood cells (RBCs/day, with platelet transfusion accounting for the largest portion of transfusion volume. Generally, adult patients require more transfusions than neonates or children, and patients receiving venovenous ECMO for respiratory failure tend to need smaller transfusion volumes compared to those receiving venoarterial ECMO for cardiac failure. Observation studies have reported that a higher transfusion volume was associated with increased mortality. To date, the evidence for transfusion in patients undergoing ECMO is limited; most knowledge on transfusion strategies was extrapolated from studies in critically ill patients. However, current data support a restrictive blood transfusion strategy for ECMO patients, and a low transfusion trigger seems to be safe and reasonable.

  11. Mechanical ventilation during extracorporeal membrane oxygenation. An international survey.

    Science.gov (United States)

    Marhong, Jonathan D; Telesnicki, Teagan; Munshi, Laveena; Del Sorbo, Lorenzo; Detsky, Michael; Fan, Eddy

    2014-07-01

    In patients with severe, acute respiratory failure undergoing venovenous extracorporeal membrane oxygenation (VV-ECMO), the optimal strategy for mechanical ventilation is unclear. Our objective was to describe ventilation practices used in centers registered with the Extracorporeal Life Support Organization (ELSO). We conducted an international cross-sectional survey of medical directors and ECMO program coordinators from all ELSO-registered centers. The survey was distributed using a commercial website that collected information on center characteristics, the presence of a mechanical ventilator protocol, ventilator settings, and weaning practices. E-mails were sent out to medical directors or coordinators at each ELSO center and their responses were pooled for analysis. We analyzed 141 (50%) individual responses from the 283 centers contacted across 28 countries. Only 27% of centers reported having an explicit mechanical ventilation protocol for ECMO patients. The majority of these centers (77%) reported "lung rest" to be the primary goal of mechanical ventilation, whereas 9% reported "lung recruitment" to be their ventilation strategy. A tidal volume of 6 ml/kg or less was targeted by 76% of respondents, and 58% targeted a positive end-expiratory pressure of 6-10 cm H2O while ventilating patients on VV-ECMO. Centers prioritized weaning VV-ECMO before mechanical ventilation. Although ventilation practices in patients supported by VV-ECMO vary across ELSO centers internationally, the majority of centers used a strategy that targeted lung-protective thresholds and prioritized weaning VV-ECMO over mechanical ventilation.

  12. Highlighting Indication of extracorporeal membrane oxygenation in endocrine emergencies.

    Science.gov (United States)

    Chao, Anne; Wang, Chih-Hsien; You, Hao-Chun; Chou, Nai-Kwoun; Yu, Hsi-Yu; Chi, Nai-Hsin; Huang, Shu-Chien; Wu, I-Hui; Tseng, Li-Jung; Lin, Ming-Hsien; Chen, Yih-Sharng

    2015-08-24

    Extracorporeal membrane oxygenation (ECMO) has been repeatedly used to rescue patients with cardiopulmonary arrest. However, its clinical utility in endocrine emergencies remains unclear. Herein, we describe a case series of 12 patients presenting with refractory shock secondary to endocrine emergencies who were rescued by ECMO support. Patients were identified between 2005 and 2012 from our ECMO registry. The diagnostic distribution was as follows: pheochromocytoma crisis (n = 4), thyroid storm (n = 5), and diabetic ketoacidosis (n = 3). The initial presentation of pheochromocytoma crisis was indistinguishable from acute myocardial infarction (AMI) and frequently accompanied by paroxysmal hypertension and limb ischemia. Thyroid storm was characterized by hyperbilirubinemia and severe gastrointestinal bleeding, whereas neurological symptoms were common in diabetic ketoacidosis. The clinical outcomes of patients with endocrine emergencies were compared with those of 80 cases with AMI who received ECMO because of cardiogenic shock. The cardiac function and the general conditions showed a significantly faster recovery in patients with endocrine emergencies than in those with AMI. We conclude that ECMO support can be clinically useful in endocrine emergencies. The screening of endocrine diseases should be considered during the resuscitation of patients with refractory circulatory shock.

  13. Extracorporeal Membrane Oxygenation in Premature Infants With Congenital Diaphragmatic Hernia.

    Science.gov (United States)

    Cuevas Guamán, Milenka; Akinkuotu, Adesola C; Cruz, Stephanie M; Griffiths, Pamela A; Welty, Stephen E; Lee, Timothy C; Olutoye, Oluyinka O

    2017-11-14

    Prematurity and low birth weight have been exclusion criteria for extracorporeal membrane oxygenation (ECMO); however, these criteria are not evidence based. With advances in anticoagulation, improved technology, and surgical expertise, it is difficult to deny a potential therapy based on these criteria alone. We report the outcome of three neonates who were ineligible based on traditional criteria but were offered ECMO as a life-saving measure. We highlight the interdisciplinary nature of modern decision-making. All three neonates had severe congenital diaphragmatic hernia diagnosed prenatally, had normal fetal karyotypes, were born prematurely, and weighed less than 2 kg. All three neonates underwent cervical venoarterial cannulation, stabilization on ECMO, and repair of their congenital diaphragmatic hernia early in their ECMO courses. All three infants had long courses of respiratory support attributable to lung hypoplasia, but there were no short- or long-term complications attributable to ECMO support directly. All three are alive at 2 years of age and were making progress developmentally. In conclusion, with interdisciplinary collaboration and clinical guidelines uniformly implemented, low birth weight infants may benefit from ECMO and should not be denied the therapy arbitrarily based on gestational age or size alone. Further research is essential to determine appropriate patient selection in premature infants.

  14. Two decades' experience with interfacility transport on extracorporeal membrane oxygenation.

    Science.gov (United States)

    Bryner, Benjamin; Cooley, Elaine; Copenhaver, William; Brierley, Kristin; Teman, Nicholas; Landis, Denise; Rycus, Peter; Hemmila, Mark; Napolitano, Lena M; Haft, Jonathan; Park, Pauline K; Bartlett, Robert H

    2014-10-01

    Interfacility transport of patients on extracorporeal membrane oxygenation (ECMO) has been performed in large numbers at only a few programs. Limited data are available on outcomes after ECMO transport to justify expanding or discontinuing these programs. This was a retrospective review of a 20-year, single-institution experience with interhospital ECMO transport as well as a systematic review of reports of transfers of patients on ECMO. Results of both were compared with historical data from the international registry of the Extracorporeal Life Support Organization (ELSO). Between 1990 and 2012, ECMO was used to facilitate transport of 221 patients to our institution, and 135 (62%) survived to discharge. Review of an additional 27 case series describing ECMO transport of 643 patients showed an overall survival of 61%. After stratifying by age and primary indication for ECMO, survival of transported patients was not significantly different compared with all ECMO patients in the ELSO registry, with the exception of pediatric patients treated for respiratory failure (transported patients in this category had higher survival than those in the ELSO registry). Interfacility transport on ECMO is feasible and can be accomplished safely in the critically ill. Survival of transported patients is comparable to age-matched and treatment-matched ECMO patients at large. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Clinical and billing review of extracorporeal membrane oxygenation.

    Science.gov (United States)

    Blum, James M; Lynch, William R; Coopersmith, Craig M

    2015-06-01

    Extracorporeal membrane oxygenation (ECMO) is a temporary technique for providing life support for cardiac dysfunction, pulmonary dysfunction, or both. The two forms of ECMO, veno-arterial (VA) and veno-venous (VV), are used to support cardiopulmonary and pulmonary dysfunction, respectively. Historically, ECMO was predominantly used in the neonatal and pediatric populations, as early adult studies failed to improve outcomes. ECMO has become far more common in the adult population because of positive results in published case series and clinical trials during the 2009 influenza A(H1N1) pandemic in 2009 to 2010. Advances in technology that make the technique much easier to implement likely fueled the renewed interest. Although exact criteria for ECMO are not available, patients who are good candidates are generally considered to be relatively young and suffering from acute illness that is believed to be reversible or organ dysfunction that is otherwise treatable. With the increase in the use in the adult population, a number of different codes have been generated to better identify the method of support with distinctly different relative value units assigned to each code from a very simple prior coding scheme. To effectively be reimbursed for use of the technique, it is imperative that the clinician understands the new coding scheme and works with payers to determine what is incorporated into each specific code.

  16. Surface strontium enrichment on highly active perovskites for oxygen electrocatalysis in solid oxide fuel cells

    KAUST Repository

    Crumlin, Ethan J.; Mutoro, Eva; Liu, Zhi; Grass, Michael E.; Biegalski, Michael D.; Lee, Yueh-Lin; Morgan, Dane; Christen, Hans M.; Bluhm, Hendrik; Shao-Horn, Yang

    2012-01-01

    Perovskite oxides have high catalytic activities for oxygen electrocatalysis competitive to platinum at elevated temperatures. However, little is known about the oxide surface chemistry that influences the activity near ambient oxygen partial pressures, which hampers the design of highly active catalysts for many clean-energy technologies such as solid oxide fuel cells. Using in situ synchrotron-based, ambient pressure X-ray photoelectron spectroscopy to study the surface chemistry changes, we show that the coverage of surface secondary phases on a (001)-oriented La 0.8Sr 0.2CoO 3-δ (LSC) film becomes smaller than that on an LSC powder pellet at elevated temperatures. In addition, strontium (Sr) in the perovskite structure enriches towards the film surface in contrast to the pellet having no detectable changes with increasing temperature. We propose that the ability to reduce surface secondary phases and develop Sr-enriched perovskite surfaces of the LSC film contributes to its enhanced activity for O 2 electrocatalysis relative to LSC powder-based electrodes. © 2012 The Royal Society of Chemistry.

  17. Preliminary analysis of 500 MWt MHD power plant with oxygen enrichment

    Science.gov (United States)

    1980-04-01

    An MHD Engineering Test Facility design concept is analyzed. A 500 MWt oxygen enriched MHD topping cycle integrated for combined cycle operation with a 400 MWe steam plant is evaluated. The MHD cycle uses Montana Rosebud coal and air enriched to 35 mole percent oxygen preheated to 1100 F. The steam plant is a 2535 psia/1000 F/1000 F reheat recycle that was scaled down from the Gilbert/Commonwealth Reference Fossil Plant design series. Integration is accomplished by blending the steam generated in the MHD heat recovery system with steam generated by the partial firing of the steam plant boiler to provide the total flow requirement of the turbine. The major MHD and steam plant auxiliaries are driven by steam turbines. When the MHD cycle is taken out of service, the steam plant is capable of stand-alone operation at turbine design throttle flow. This operation requires the full firing of the steam plant boiler. A preliminary feasibility assessment is given, and results on the system thermodynamics, construction scheduling, and capital costs are presented.

  18. Surface oxygen vacancy and oxygen permeation flux limits of perovskite ion transport membranes

    KAUST Repository

    Hunt, Anton

    2015-09-01

    © 2015 Elsevier B.V. The mechanisms and quantitative models for how oxygen is separated from air using ion transport membranes (ITMs) are not well understood, largely due to the experimental complexity for determining surface exchange reactions at extreme temperatures (>800°C). This is especially true when fuels are present at the permeate surface. For both inert and reactive (fuels) operations, solid-state oxygen surface vacancies (δ) are ultimately responsible for driving the oxygen flux, JO2. In the inert case, the value of δ at either surface is a function of the local PO2 and temperature, whilst the magnitude of δ dictates both the JO2 and the inherent stability of the material. In this study values of δ are presented based on experimental measurements under inert (CO2) sweep: using a permeation flux model and local PO2 measurements, collected by means of a local gas-sampling probe in our large-scale reactor, we can determine δ directly. The ITM assessed was La0.9Ca0.1FeO3-δ (LCF); the relative resistances to JO2 were quantified using the pre-defined permeation flux model and local PO2 values. Across a temperature range from 825°C to 1056°C, δ was found to vary from 0.007 to 0.029 (<1%), safely within material stability limits, whilst the permeate surface exchange resistance dominates. An inert JO2 limit was identified owing to a maximum sweep surface δ, δmaxinert. The physical presence of δmaxinert is attributed to a rate limiting step shift from desorption to associative electron transfer steps on the sweep surface as PO2 is reduced. Permeate surface exchange limitations under non-reactive conditions suggest that reactive (fuel) operation is necessary to accelerate surface chemistry for future work, to reduce flux resistance and push δpast δmaxinert in a stable manner.

  19. Effect of administration of water enriched in O2 by injection or electrolysis on transcutaneous oxygen pressure in anesthetized pigs.

    Science.gov (United States)

    Charton, Antoine; Péronnet, François; Doutreleau, Stephane; Lonsdorfer, Evelyne; Klein, Alexis; Jimenez, Liliana; Geny, Bernard; Diemunsch, Pierre; Richard, Ruddy

    2014-01-01

    Oral administration of oxygenated water has been shown to improve blood oxygenation and could be an alternate way for oxygen (O2) supply. In this experiment, tissue oxygenation was compared in anesthetized pigs receiving a placebo or water enriched in O2 by injection or a new electrolytic process. Forty-two pigs randomized in three groups received either mineral water as placebo or water enriched in O2 by injection or the electrolytic process (10 mL/kg in the stomach). Hemodynamic parameters, partial pressure of oxygen in the arterial blood (PaO2), skin blood flow, and tissue oxygenation (transcutaneous oxygen pressure, or TcPO2) were monitored during 90 minutes of general anesthesia. Absorption and tissue distribution of the three waters administered were assessed using dilution of deuterium oxide. Mean arterial pressure, heart rate, PaO2, arteriovenous oxygen difference, and water absorption from the gut were not significantly different among the three groups. The deuterium to protium ratio was also similar in the plasma, skin, and muscle at the end of the protocol. Skin blood flow decreased in the three groups. TcPO2 slowly decreased over the last 60 minutes of the experiment in the three groups, but when compared to the control group, the values remained significantly higher in animals that received the water enriched in O2 by electrolysis. In this protocol, water enriched in O2 by electrolysis lessened the decline of peripheral tissue oxygenation. This observation is compatible with the claim that the electrolytic process generates water clathrates which trap O2 and facilitate O2 diffusion along pressure gradients. Potential applications of O2-enriched water include an alternate method of oxygen supply.

  20. Enriched glucose and dextrin mannitol-based media modulates fibroblast behavior on bacterial cellulose membranes

    International Nuclear Information System (INIS)

    Stumpf, Taisa R.; Pértile, Renata A.N.; Rambo, Carlos R.; Porto, Luismar M.

    2013-01-01

    Bacterial cellulose (BC) produced by Gluconacetobacter hansenii is a suitable biopolymer for biomedical applications. In order to modulate the properties of BC and expand its use as substrate for tissue engineering mainly in the form of biomembranes, glucose or dextrin were added into a BC fermentation mannitol-based medium (BCGl and BCDe, respectively) under static culture conditions. SEM images showed effects on fiber density and porosity on both sides of the BC membranes. Both enriched media decreased the BET surface area, water holding capacity, and rehydration rate. Fourier transform infrared (attenuated total reflectance mode) spectroscopy (FTIR-ATR) analysis revealed no change in the chemical structure of BC. L929 fibroblast cells were seeded on all BC-based membranes and evaluated in aspects of cell adhesion, proliferation and morphology. BCG1 membranes showed the highest biological performance and hold promise for the use in tissue engineering applications. - Highlights: • Glucose and dextrin were used to modify culture media for BC production. • Microarchitecture of BC was different depending on the enriching agent. • Fibroblasts adhered on the surface of BC modified microarchitectures. • Fibroblasts adhered on glucose modified BC exhibited healthy cell morphology

  1. Enriched glucose and dextrin mannitol-based media modulates fibroblast behavior on bacterial cellulose membranes

    Energy Technology Data Exchange (ETDEWEB)

    Stumpf, Taisa R.; Pértile, Renata A.N. [Integrated Technologies Laboratory, Department of Chemical and Food Engineering (Brazil); Rambo, Carlos R., E-mail: rambo@intelab.ufsc.br [Department of Electrical Engineering, Federal University of Santa Catarina, Florianópolis 88040-900 (Brazil); Porto, Luismar M. [Integrated Technologies Laboratory, Department of Chemical and Food Engineering (Brazil)

    2013-12-01

    Bacterial cellulose (BC) produced by Gluconacetobacter hansenii is a suitable biopolymer for biomedical applications. In order to modulate the properties of BC and expand its use as substrate for tissue engineering mainly in the form of biomembranes, glucose or dextrin were added into a BC fermentation mannitol-based medium (BCGl and BCDe, respectively) under static culture conditions. SEM images showed effects on fiber density and porosity on both sides of the BC membranes. Both enriched media decreased the BET surface area, water holding capacity, and rehydration rate. Fourier transform infrared (attenuated total reflectance mode) spectroscopy (FTIR-ATR) analysis revealed no change in the chemical structure of BC. L929 fibroblast cells were seeded on all BC-based membranes and evaluated in aspects of cell adhesion, proliferation and morphology. BCG1 membranes showed the highest biological performance and hold promise for the use in tissue engineering applications. - Highlights: • Glucose and dextrin were used to modify culture media for BC production. • Microarchitecture of BC was different depending on the enriching agent. • Fibroblasts adhered on the surface of BC modified microarchitectures. • Fibroblasts adhered on glucose modified BC exhibited healthy cell morphology.

  2. Oxygen Transport Membranes: A Material Science and Process Engineering Approach

    NARCIS (Netherlands)

    Chen, Wei

    2014-01-01

    This thesis describes several fundamental aspects on the membrane-integrated oxy-fuel combustion process and can be divided in two parts: 1) The development and characterization of membrane materials; 2) The design, simulation and evaluation of a coal-fired power plant, coupled with a membrane

  3. Logistics and safety of extracorporeal membrane oxygenation in medical retrieval.

    Science.gov (United States)

    Burns, Brian J; Habig, Karel; Reid, Cliff; Kernick, Paul; Wilkinson, Chris; Tall, Gary; Coombes, Sarah; Manning, Ron

    2011-01-01

    This article reviews the logistics and safety of extracorporeal membrane oxygenation (ECMO) medical retrieval in New South Wales, Australia. We describe the logistics involved in ECMO road and rotary-wing retrieval by a multidisciplinary team during the H1N1 influenza epidemic in winter 2009 (i.e., June 1 to August 31, 2009). Basic patient demographics and key retrieval time lines were analyzed. There were 17 patients retrieved on ECMO, with their ages ranging from 22 to 55 years. The median weight was 110 kg. Four critical events were recorded during retrieval, with no adverse outcomes. The retrieval distance varied from 20.8 to 430 km. There were delays in times from retrieval booking to both retrieval tasking and retrieval team departure in 88% of retrievals. The most common reasons cited were "patient not ready" 23.5% (4/17); "vehicle not available," 23.5% (4/17); and "complex retrieval," 41.2% (7/17). The median time (hours:minutes) from booking with the medical retrieval unit (MRU) to tasking was 4:35 (interquartile range [IQR] 3:27-6:15). The median time lag from tasking to departure was 1:00 (IQR 00:10-2:20). The median stabilization time was 1:30 (IQR 1:20-1:55). The median retrieval duration was 7:35 (IQR 5:50-10:15). The process of development of ECMO retrieval was enabled by the preexistence of a high-volume experienced medical retrieval service. Although ECMO retrieval is not a new concept, we describe an entire process for ECMO retrieval that we believe will benefit other retrieval service providers. The increased workload of ECMO retrieval during the swine flu pandemic has led to refinement in the system and process for the future.

  4. Extracorporeal membranous oxygenation (ecmo in children – 12 years experience

    Directory of Open Access Journals (Sweden)

    Janez Primožič

    2006-02-01

    Full Text Available Background: Extracorporeal membranous oxigenation (ECMO is an established treatment of children with severe yet amenable lung or heart failure.Methods: Retrospective analysis of 12 years of experience (1994–2005 includes: a ECMO treatment type, b selection and status of children upon connection, c percentage and quality of survival, d influence of pre-ECMO risk factors on survival, and e complications.Results: ECMO was applied in 18 children: veno-venous type in 6 (33%, veno-arterial in 12 (66% children. All children had deep hipoxy and 80% probability of dying. There were 12 boys (66% and 6 girls (34%. The majority were newborns – there were 12 (66% while the other 6 children (34% were aged 2 to 24 months. Average duration of ECMO in newborns was 131 hours (SD 83; range 27–288, and in older children 253 hours (151; 45–434. Average birth weight of newborns was 3190 g (654; 2320–4360, average gestation age 38.5 weeks (2.2; 34–41. Of the 18 children treated with ECMO, 11 survived (61%, while 4 died subsequently. Observed 24 hours after ECMO survival rate was higher in newborns (67% than in older children (50%, but the difference was not statistically significant (p = 0.627. Up to the present, 7 of the 11 have survived, five reached normal mental and physical development at final check-up, one has moderate motor disturbances with behavioural disorders, one has severe disability. It can be inferred that in addition to oxygenation index, plasma HCO3 level, mean arterial blood pressure and mean airway pressure before ECMO treatment are potential prognostic factors for newborn survival.Conclusions: The results of ECMO treatment justify the use and continuation of the ECMO programme in Slovenia.

  5. Deposition of Lanthanum Strontium Cobalt Ferrite (LSCF) Using Suspension Plasma Spraying for Oxygen Transport Membrane Applications

    Science.gov (United States)

    Fan, E. S. C.; Kesler, O.

    2015-08-01

    Suspension plasma spray deposition was utilized to fabricate dense lanthanum strontium cobalt ferrite oxygen separation membranes (OSMs) on porous metal substrates for mechanical support. The as-sprayed membranes had negligible and/or reversible material decomposition. At the longer stand-off distance (80 mm), smooth and dense membranes could be manufactured using a plasma with power below approximately 81 kW. Moreover, a membrane of 55 μm was observed to have very low gas leakage rates desirable for OSM applications. This thickness could potentially be decreased further to improve oxygen diffusion by using metal substrates with finer surface pores.

  6. Influence of Cholesterol on the Oxygen Permeability of Membranes: Insight from Atomistic Simulations.

    Science.gov (United States)

    Dotson, Rachel J; Smith, Casey R; Bueche, Kristina; Angles, Gary; Pias, Sally C

    2017-06-06

    Cholesterol is widely known to alter the physical properties and permeability of membranes. Several prior works have implicated cell membrane cholesterol as a barrier to tissue oxygenation, yet a good deal remains to be explained with regard to the mechanism and magnitude of the effect. We use molecular dynamics simulations to provide atomic-resolution insight into the influence of cholesterol on oxygen diffusion across and within the membrane. Our simulations show strong overall agreement with published experimental data, reproducing the shapes of experimental oximetry curves with high accuracy. We calculate the upper-limit transmembrane oxygen permeability of a 1-palmitoyl,2-oleoylphosphatidylcholine phospholipid bilayer to be 52 ± 2 cm/s, close to the permeability of a water layer of the same thickness. With addition of cholesterol, the permeability decreases somewhat, reaching 40 ± 2 cm/s at the near-saturating level of 62.5 mol % cholesterol and 10 ± 2 cm/s in a 100% cholesterol mimic of the experimentally observed noncrystalline cholesterol bilayer domain. These reductions in permeability can only be biologically consequential in contexts where the diffusional path of oxygen is not water dominated. In our simulations, cholesterol reduces the overall solubility of oxygen within the membrane but enhances the oxygen transport parameter (solubility-diffusion product) near the membrane center. Given relatively low barriers to passing from membrane to membrane, our findings support hydrophobic channeling within membranes as a means of cellular and tissue-level oxygen transport. In such a membrane-dominated diffusional scheme, the influence of cholesterol on oxygen permeability is large enough to warrant further attention. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  7. Minerals in the Ash and Slag from Oxygen-Enriched Underground Coal Gasification

    Directory of Open Access Journals (Sweden)

    Shuqin Liu

    2016-03-01

    Full Text Available Underground coal gasification (UCG is a promising option for the recovery of low-rank and inaccessible coal resources. Detailed mineralogical information is essential to understand underground reaction conditions far from the surface and optimize the operation parameters during the UCG process. It is also significant in identifying the environmental effects of UCG residue. In this paper, with regard to the underground gasification of lignite, UCG slag was prepared through simulation tests of oxygen-enriched gasification under different atmospheric conditions, and the minerals were identified by X-Ray diffraction (XRD and a scanning electron microscope coupled to an energy-dispersive spectrometer (SEM-EDS. Thermodynamic calculations performed using FactSage 6.4 were used to help to understand the transformation of minerals. The results indicate that an increased oxygen concentration is beneficial to the reformation of mineral crystal after ash fusion and the resulting crystal structures of minerals also tend to be more orderly. The dominant minerals in 60%-O2 and 80%-O2 UCG slag include anorthite, pyroxene, and gehlenite, while amorphous substances almost disappear. In addition, with increasing oxygen content, mullite might react with the calcium oxide existed in the slag to generate anorthite, which could then serve as a calcium source for the formation of gehlenite. In 80%-O2 UCG slag, the iron-bearing mineral is transformed from sekaninaite to pyroxene.

  8. Determinants of oxygen and carbon dioxide transfer during extracorporeal membrane oxygenation in an experimental model of multiple organ dysfunction syndrome.

    Science.gov (United States)

    Park, Marcelo; Costa, Eduardo Leite Vieira; Maciel, Alexandre Toledo; Silva, Débora Prudêncio E; Friedrich, Natalia; Barbosa, Edzangela Vasconcelos Santos; Hirota, Adriana Sayuri; Schettino, Guilherme; Azevedo, Luciano Cesar Pontes

    2013-01-01

    Extracorporeal membrane oxygenation (ECMO) has gained renewed interest in the treatment of respiratory failure since the advent of the modern polymethylpentene membranes. Limited information exists, however, on the performance of these membranes in terms of gas transfers during multiple organ failure (MOF). We investigated determinants of oxygen and carbon dioxide transfer as well as biochemical alterations after the circulation of blood through the circuit in a pig model under ECMO support before and after induction of MOF. A predefined sequence of blood and sweep flows was tested before and after the induction of MOF with fecal peritonitis and saline lavage lung injury. In the multivariate analysis, oxygen transfer had a positive association with blood flow (slope = 66, Pmembrane PaCO(2) (slope = -0.96, P = 0.001) and SatO(2) (slope = -1.7, Ptransfer had a positive association with blood flow (slope = 17, Pmembrane PaCO(2) (slope = 1.2, Ptransfers were significantly determined by blood flow. Oxygen transfer was modulated by the pre-membrane SatO(2) and CO(2), while carbon dioxide transfer was affected by the gas flow, pre-membrane CO(2) and hemoglobin.

  9. Interactions between oxygen permeation and homogeneous-phase fuel conversion on the sweep side of an ion transport membrane

    KAUST Repository

    Hong, Jongsup; Kirchen, Patrick; Ghoniem, Ahmed F.

    2013-01-01

    concentration enhances oxygen permeation substantially. This is accomplished through promoting oxidation reactions (oxygen consumption) and the transport of the products and reaction heat towards the membrane, which lowers the oxygen concentration and increases

  10. Prognostic value of cerebral tissue oxygen saturation during neonatal extracorporeal membrane oxygenation.

    Directory of Open Access Journals (Sweden)

    Marie-Philippine Clair

    Full Text Available Extracorporeal membrane oxygenation support is indicated in severe and refractory respiratory or circulatory failures. Neurological complications are typically represented by acute ischemic or hemorrhagic lesions, which induce higher morbidity and mortality. The primary goal of this study was to assess the prognostic value of cerebral tissue oxygen saturation (StcO2 on mortality in neonates and young infants treated with ECMO. A secondary objective was to evaluate the association between StcO2 and the occurrence of cerebral lesions.This was a prospective study in infants < 3 months of age admitted to a pediatric intensive care unit and requiring ECMO support.The assessment of cerebral perfusion was made by continuous StcO2 monitoring using near-infrared spectroscopy (NIRS sensors placed on the two temporo-parietal regions. Neurological lesions were identified by MRI or transfontanellar echography.Thirty-four infants <3 months of age were included in the study over a period of 18 months. The ECMO duration was 10±7 days. The survival rate was 50% (17/34 patients, and the proportion of brain injuries was 20% (7/34 patients. The mean StcO2 during ECMO in the non-survivors was reduced in both hemispheres (p = 0.0008 right, p = 0.03 left compared to the survivors. StcO2 was also reduced in deceased or brain-injured patients compared to the survivors without brain injury (p = 0.002.StcO2 appears to be a strong prognostic factor of survival and of the presence of cerebral lesions in young infants during ECMO.

  11. Evaluation of furosemide regimens in neonates treated with extracorporeal membrane oxygenation

    NARCIS (Netherlands)

    M.M.J. van der Vorst (Maria); E.D. Wildschut (Enno); R.J.M. Houmes (Robert Jan); S.J. Gischler (Saskia); J.E. Kist-Van Holthe (Joana); J. Burggraaf (Jacobus); A.J. van der Heijden (Bert); D. Tibboel (Dick)

    2006-01-01

    textabstractIntroduction: Loop diuretics are the most frequently used diuretics in patients treated with extracorporeal membrane oxygenation (ECMO). In patients after cardiopulmonary bypass (CPB) surgery, the use of continuous furosemide infusion is increasingly documented. Because ECMO and CPB are

  12. Neonatal and pediatric extracorporeal membrane oxygenation in developing Latin American countries

    OpenAIRE

    Kattan, Javier; González, Álvaro; Castillo, Andrés; Caneo, Luiz Fernando

    2017-01-01

    Objective: To review the principles of neonatal‐pediatric extracorporeal membrane oxygenation therapy, prognosis, and its establishment in limited resource‐limited countries in Latino America. Sources: The PubMed database was explored from 1985 up to the present, selecting from highly‐indexed and leading Latin American journals, and Extracorporeal Life Support Organization reports. Summary of the findings: Extracorporeal membrane oxygenation provides “time” for pulmonary and cardiac res...

  13. Neonatal and pediatric extracorporeal membrane oxygenation in developing Latin American countries

    Directory of Open Access Journals (Sweden)

    Javier Kattan

    2017-03-01

    Conclusions: The best results in short‐ and long‐term survival are in patients with isolated respiratory diseases. Today extracorporeal membrane oxygenation therapy is a standard therapy in some Latin American referral centers. It is hoped that these new extracorporeal membrane oxygenation centers will have a positive impact on the survival of newborns and children with respiratory or cardiac failure, and that they will be available for an increasing number of patients from this region in the near future.

  14. Effects of radiation on the physical properties of PP membrane for the removal of dissolved oxygen

    International Nuclear Information System (INIS)

    Kang, D. W.; Song, Y. W.; Kim, M. S.; Ji, J. H.; Kim, S. I.

    2003-01-01

    The physical properties of polypropylene (PP) hollow fiber membranes and its deoxygenation efficiency were investigated. We supposed the conditions of PP hollow fiber membranes under radiation field and irradiated the PP membranes using differential scanning calorimetry(DSC), thermal gravimetric analyzer (TGA), fourier transform infrared (FT-IR), and contact angle. In addition, the deoxygenation efficiency of the exposed PP membranes was estimated by using an oxygen removal test kit. From the results, we found that the physical properties and deoxygenation efficiency of PP membrane was still keep good condition under the simulated radiation field

  15. Extracorporeal membrane oxygenation in a Scottish intensive care unit.

    Science.gov (United States)

    Berryman, Sean

    2010-01-01

    I reflected on the training I had on an extraordinary treatment for profound respiratory failure. The result of training enabled us to successfully treat a young female with the influenza A virus with extracorporeal membrane oxygenation (ECMO). I report the positive outcome that occurred, while continuing to run a busy general intensive care unit (ICU). She was the first of six patients who were all successfully treated with ECMO. Ten trained and experienced critical care nurses and two doctors attended the ECMO training course provided by the national centre in the UK. Five patients had already received ECMO therapy in the Scottish specialist unit (over the period of 8 years). As our Scottish specialist unit purchased exactly the same equipment as the national centre, it was easier for the multidisciplinary team to utilize their new-found knowledge and treat future patients with ECMO. With the predicted swine flu (H1N1) pandemic and the subsequent demand for critical care beds, funding was obtained to facilitate ECMO training. The potential need for increased provision of ECMO therapies was highlighted by recent events in Australia and New Zealand. Their most recent winter produced 68 patients requiring ECMO, whereas the previous year had manifested only three. Using our new equipment and adapted protocols from the national centre, we used these new skills to treat our first patient in October 2009. Johns' reflective practice tool was used to evaluate the care provided. Our patient was on ECMO for 9 days. She went on to make a remarkable recovery and was discharged from the ICU 1 week after ECMO was discontinued. She was discharged to the cardiothoracic high-dependency unit, where she was successfully rehabilitated. We were able to successfully treat a young lady, while providing the care for all other patients. This was a complex treatment, one that uses many resources including time and finance. Now that we have all the equipment, the necessary training and the

  16. Trough Concentrations of Vancomycin in Patients Undergoing Extracorporeal Membrane Oxygenation.

    Directory of Open Access Journals (Sweden)

    So Jin Park

    Full Text Available To investigate the appropriateness of the current vancomycin dosing strategy in adult patients with extracorporeal membrane oxygenation (ECMO, between March 2013 and November 2013, patients who were treated with vancomycin while on ECMO were enrolled. Control group consisted of 60 patients on vancomycin without ECMO, stayed in medical intensive care unit during the same study period and with the same exclusion criteria. Early trough levels were obtained within the fourth dosing, and maintenance levels were measured at steady state. A total of 20 patients were included in the analysis in ECMO group. Sixteen patients received an initial intravenous dose of 1.0 g vancomycin followed by 1.0 g every 12 hours. The non-steady state trough level of vancomycin after starting administration was subtherapeutic in 19 patients (95.00% in ECMO group as compared with 40 patients (66.67% in the control group (p = 0.013. Vancomycin clearance was 1.27±0.51 mL/min/kg, vancomycin clearance/creatinine clearance ratio was 0.90 ± 0.37, and elimination rate constant was 0.12 ± 0.04 h-1. Vancomycin dosingfrequency and total daily dose were significantly increased after clinical pharmacokinetic services of the pharmacist based on calculated pharmacokinetic parameters (from 2.10 ± 0.72 to 2.90 ± 0.97 times/day, p = 0.002 and from 32.54 ± 8.43 to 42.24 ± 14.62mg/kg, p = 0.014 in ECMO group in contrast with those (from 2.11 ± 0.69 to 2.37 ± 0.86 times/day, p = 0.071 and from 33.91 ± 11.85 to 31.61 ± 17.50 mg/kg, p = 0.350 in the control group.Although the elimination rate for vancomycin was similar with population parameter of non ECMO patients, the current dosing strategy of our institution for vancomycinin our ICU was not sufficient to achieve the target trough in the initial period in most patients receiving ECMO.

  17. Experience and needs of family members of patients treated with extracorporeal membrane oxygenation.

    Science.gov (United States)

    Tramm, Ralph; Ilic, Dragan; Murphy, Kerry; Sheldrake, Jayne; Pellegrino, Vincent; Hodgson, Carol

    2017-06-01

    To explore the experiences of family members of patients treated with extracorporeal membrane oxygenation. Sudden onset of an unexpected and severe illness is associated with an increased stress experience of family members. Only one study to date has explored the experience of family members of patients who are at high risk of dying and treated with extracorporeal membrane oxygenation. A qualitative descriptive research design was used. A total of 10 family members of patients treated with extracorporeal membrane oxygenation were recruited through a convenient sampling approach. Data were collected using open-ended semi-structured interviews. A six-step process was applied to analyse the data thematically. Four criteria were employed to evaluate methodological rigour. Family members of extracorporeal membrane oxygenation patients experienced psychological distress and strain during and after admission. Five main themes (Going Downhill, Intensive Care Unit Stress and Stressors, Carousel of Roles, Today and Advice) were identified. These themes were explored from the four roles of the Carousel of Roles theme (decision-maker, carer, manager and recorder) that participants experienced. Nurses and other staff involved in the care of extracorporeal membrane oxygenation patients must pay attention to individual needs of the family and activate all available support systems to help them cope with stress and strain. An information and recommendation guide for families and staff caring for extracorporeal membrane oxygenation patients was developed and needs to be applied cautiously to the individual clinical setting. © 2016 John Wiley & Sons Ltd.

  18. Analysis of heterogeneous oxygen exchange and fuel oxidation on the catalytic surface of perovskite membranes

    KAUST Repository

    Hong, Jongsup

    2013-10-01

    The catalytic kinetics of oxygen surface exchange and fuel oxidation for a perovskite membrane is investigated in terms of the thermodynamic state in the immediate vicinity of or on the membrane surface. Perovskite membranes have been shown to exhibit both oxygen perm-selectivity and catalytic activity for hydrocarbon conversion. A fundamental description of their catalytic surface reactions is needed. In this study, we infer the kinetic parameters for heterogeneous oxygen surface exchange and catalytic fuel conversion reactions, based on permeation rate measurements and a spatially resolved physical model that incorporates detailed chemical kinetics and transport in the gas-phase. The conservation equations for surface and bulk species are coupled with those of the gas-phase species through the species production rates from surface reactions. It is shown that oxygen surface exchange is limited by dissociative/associative adsorption/desorption of oxygen molecules onto/from the membrane surface. On the sweep side, while the catalytic conversion of methane to methyl radical governs the overall surface reactions at high temperature, carbon monoxide oxidation on the membrane surface is dominant at low temperature. Given the sweep side conditions considered in ITM reactor experiments, gas-phase reactions also play an important role, indicating the significance of investigating both homogeneous and heterogeneous chemistry and their coupling when examining the results. We show that the local thermodynamic state at the membrane surface should be considered when constructing and examining models of oxygen permeation and heterogeneous chemistry. © 2013 Elsevier B.V.

  19. Analysis of heterogeneous oxygen exchange and fuel oxidation on the catalytic surface of perovskite membranes

    KAUST Repository

    Hong, Jongsup; Kirchen, Patrick; Ghoniem, Ahmed F.

    2013-01-01

    The catalytic kinetics of oxygen surface exchange and fuel oxidation for a perovskite membrane is investigated in terms of the thermodynamic state in the immediate vicinity of or on the membrane surface. Perovskite membranes have been shown to exhibit both oxygen perm-selectivity and catalytic activity for hydrocarbon conversion. A fundamental description of their catalytic surface reactions is needed. In this study, we infer the kinetic parameters for heterogeneous oxygen surface exchange and catalytic fuel conversion reactions, based on permeation rate measurements and a spatially resolved physical model that incorporates detailed chemical kinetics and transport in the gas-phase. The conservation equations for surface and bulk species are coupled with those of the gas-phase species through the species production rates from surface reactions. It is shown that oxygen surface exchange is limited by dissociative/associative adsorption/desorption of oxygen molecules onto/from the membrane surface. On the sweep side, while the catalytic conversion of methane to methyl radical governs the overall surface reactions at high temperature, carbon monoxide oxidation on the membrane surface is dominant at low temperature. Given the sweep side conditions considered in ITM reactor experiments, gas-phase reactions also play an important role, indicating the significance of investigating both homogeneous and heterogeneous chemistry and their coupling when examining the results. We show that the local thermodynamic state at the membrane surface should be considered when constructing and examining models of oxygen permeation and heterogeneous chemistry. © 2013 Elsevier B.V.

  20. Enrichment and proteomic analysis of plasma membrane from rat dorsal root ganglions

    Directory of Open Access Journals (Sweden)

    Lin Yong

    2009-11-01

    Full Text Available Abstract Background Dorsal root ganglion (DRG neurons are primary sensory neurons that conduct neuronal impulses related to pain, touch and temperature senses. Plasma membrane (PM of DRG cells plays important roles in their functions. PM proteins are main performers of the functions. However, mainly due to the very low amount of DRG that leads to the difficulties in PM sample collection, few proteomic analyses on the PM have been reported and it is a subject that demands further investigation. Results By using aqueous polymer two-phase partition in combination with high salt and high pH washing, PMs were efficiently enriched, demonstrated by western blot analysis. A total of 954 non-redundant proteins were identified from the plasma membrane-enriched preparation with CapLC-MS/MS analysis subsequent to protein separation by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE or shotgun digestion. 205 (21.5% of the identified proteins were unambiguously assigned as PM proteins, including a large number of signal proteins, receptors, ion channel and transporters. Conclusion The aqueous polymer two-phase partition is a simple, rapid and relatively inexpensive method. It is well suitable for the purification of PMs from small amount of tissues. Therefore, it is reasonable for the DRG PM to be enriched by using aqueous two-phase partition as a preferred method. Proteomic analysis showed that DRG PM was rich in proteins involved in the fundamental biological processes including material exchange, energy transformation and information transmission, etc. These data would help to our further understanding of the fundamental DRG functions.

  1. Prospective longitudinal evaluation of lung function during the first year of life after extracorporeal membrane oxygenation

    NARCIS (Netherlands)

    Hofhuis, W.; Hanekamp, M.N.; Ijsselstijn, H.; Nieuwhof, E.M.; Hop, W.C.J.; Tibboel, D.; Jongste, J.C. de; Merkus, P.J.F.M.

    2011-01-01

    OBJECTIVE: To collect longitudinal data on lung function in the first year of life after extracorporeal membrane oxygenation and to evaluate relationships between lung function and perinatal factors. Longitudinal data on lung function in the first year of life after extracorporeal membrane

  2. Quantitative membrane proteomics reveals a role for tetraspanin enriched microdomains during entry of human cytomegalovirus.

    Directory of Open Access Journals (Sweden)

    Kasinath Viswanathan

    Full Text Available Human cytomegalovirus (HCMV depends on and modulates multiple host cell membrane proteins during each stage of the viral life cycle. To gain a global view of the impact of HCMV-infection on membrane proteins, we analyzed HCMV-induced changes in the abundance of membrane proteins in fibroblasts using stable isotope labeling with amino acids (SILAC, membrane fractionation and protein identification by two-dimensional liquid chromatography and tandem mass spectrometry. This systematic approach revealed that CD81, CD44, CD98, caveolin-1 and catenin delta-1 were down-regulated during infection whereas GRP-78 was up-regulated. Since CD81 downregulation was also observed during infection with UV-inactivated virus we hypothesized that this tetraspanin is part of the viral entry process. Interestingly, additional members of the tetraspanin family, CD9 and CD151, were also downregulated during HCMV-entry. Since tetraspanin-enriched microdomains (TEM cluster host cell membrane proteins including known CMV receptors such as integrins, we studied whether TEMs are required for viral entry. When TEMs were disrupted with the cholesterol chelator methyl-β-cylcodextrin, viral entry was inhibited and this inhibition correlated with reduced surface levels of CD81, CD9 and CD151, whereas integrin levels remained unchanged. Furthermore, simultaneous siRNA-mediated knockdown of multiple tetraspanins inhibited viral entry whereas individual knockdown had little effect suggesting essential, but redundant roles for individual tetraspanins during entry. Taken together, our data suggest that TEM act as platforms for receptors utilized by HCMV for entry into cells.

  3. ExtraCorporeal Membrane Oxygenation in Newborns. Implications for Brain and Lung.

    NARCIS (Netherlands)

    Heyst, A.F.J. van

    2004-01-01

    Extracorporeal membrane oxygenation (ECMO) is a rescue treatment for newborns with severe respiratory insufficiency. In veno-arterial ECMO, venous blood is drained from the right atrium, oxygenated in an artificial lung and reinfused in the aorta. For vascular access the right internal jugular vein

  4. Oxygen Transfer Model for a Flow-Through Hollow-Fiber Membrane Biofilm Reactor

    DEFF Research Database (Denmark)

    Gilmore, K. R.; Little, J. C.; Smets, Barth F.

    2009-01-01

    overpredicted the oxygen transfer by a factor of 1.3 relative to the result calculated from the outlet gas oxygen concentration, which was considered the most accurate of the measured benchmarks. A mass transfer coefficient derived from the clean water testing with oxygen sensors at the membrane......-liquid interface was the most accurate of the predictive models (overpredicted by a factor of 1.1) while a coefficient determined by measuring bulk liquid dissolved oxygen underpredicted the oxygen transfer by a factor of 3. The mechanistic model was found to be an adequate tool for design because it used...

  5. Review of 1,000 consecutive extracorporeal membrane oxygenation runs as a quality initiative.

    Science.gov (United States)

    Lovvorn, Harold N; Hardison, Daphne C; Chen, Heidi; Westrick, Ashly C; Danko, Melissa E; Bridges, Brian C; Walsh, William F; Pietsch, John B

    2017-08-01

    Extracorporeal membrane oxygenation is a resource-intensive mode of life-support potentially applicable when conventional therapies fail. Given the initial success of extracorporeal membrane oxygenation to support neonates and infants in the 1980s, indications have expanded to include adolescents, adults, and selected moribund patients during cardiopulmonary resuscitation. This single-institution analysis was conducted to evaluate programmatic growth, outcomes, and risk for death despite extracorporeal membrane oxygenation across all ages and diseases. Beginning in 1989, we registered prospectively all extracorporeal membrane oxygenation patient data with the Extracorporeal Life Support Organization. We queried this registry for our institution-specific data to compare the parameter of "discharge alive" between age groups (neonatal, pediatric, adult), disease groups (respiratory, cardiac, cardiopulmonary resuscitation), and modes of extracorporeal membrane oxygenation (veno-venous; veno-arterial). Extracorporeal membrane oxygenation-specific complications (mechanical, hemorrhagic, neurologic, renal, cardiovascular, pulmonary, infectious, metabolic) were analyzed similarly. Descriptive statistics, Kaplan-Meier, and linear regression analyses were conducted. After 1,052 extracorporeal membrane oxygenation runs, indications have expanded to include adults, to supplement cardiopulmonary resuscitation, to support hemodialysis in neonates and plasmapheresis in children, and to bridge all age patients to heart and lung transplant. Overall survival to discharge was 52% and was better for respiratory diseases (P < .001). Probability of individual survival decreased to <50% if pre-extracorporeal membrane oxygenation mechanical ventilation exceeded respectively 123 hours for cardiac, 166 hours for cardiopulmonary resuscitation, and 183 hours for respiratory diseases (P = .013). Complications occurred most commonly among cardiac and cardiopulmonary resuscitation runs

  6. Potential benefits of oxygen-enriched intake air in a vehicle powered by a spark-ignition engine

    Science.gov (United States)

    Ng, H. K.; Sekar, R. R.

    1994-04-01

    A production vehicle powered by a spark-ignition engine (3.1-L Chevrolet Lumina, model year 1990) was tested. The test used oxygen-enriched intake air containing 25 and 28% oxygen by volume to determine (1) if the vehicle would run without difficulties and (2) if emissions benefits would result. Standard Federal Test Procedure (FTP) emissions test cycles were run satisfactorily. Test results of catalytic converter-out emissions (emissions out of the converter) showed that both carbon monoxide and hydrocarbons were reduced significantly in all three phases of the emissions test cycle. Test results of engine-out emissions (emissions straight out of the engine, with the converter removed) showed that carbon monoxide was significantly reduced in the cold phase. All emission test results were compared with those for normal air (21% oxygen). The catalytic converter also had an improved carbon monoxide conversion efficiency under the oxygen-enriched-air conditions. Detailed results of hydrocarbon speciation indicated large reductions in 1,3-butadiene, formaldehyde, acetaldehyde, and benzene from the engine with the oxygen-enriched air. Catalytic converter-out ozone was reduced by 60% with 25%-oxygen-content air. Although NO(x) emissions increased significantly, both for engine-out and catalytic converter-out emissions, we anticipate that they can be ameliorated in the near future with new control technologies. The automotive industry currently is developing exhaust-gas control technologies for an oxidizing environment; these technologies should reduce NO(x) emissions more efficiently in vehicles that use oxygen-enriched intake air. On the basis of estimates made from current data, several production vehicles that had low NO(x) emissions could meet the 2004 Tier 2 emissions standards with 25%-oxygen-content air.

  7. Myocardial Oxidative Metabolism and Protein Synthesis during Mechanical Circulatory Support by Extracorporeal Membrane Oxygenation

    Energy Technology Data Exchange (ETDEWEB)

    Priddy, MD, Colleen M.; Kajimoto, Masaki; Ledee, Dolena; Bouchard, Bertrand; Isern, Nancy G.; Olson, Aaron; Des Rosiers, Christine; Portman, Michael A.

    2013-02-01

    Extracorporeal membrane oxygenation (ECMO) provides mechanical circulatory support essential for survival in infants and children with acute cardiac decompensation. However, ECMO also causes metabolic disturbances, which contribute to total body wasting and protein loss. Cardiac stunning can also occur which prevents ECMO weaning, and contributes to high mortality. The heart may specifically undergo metabolic impairments, which influence functional recovery. We tested the hypothesis that ECMO alters oxidative. We focused on the amino acid leucine, and integration with myocardial protein synthesis. We used a translational immature swine model in which we assessed in heart (i) the fractional contribution of leucine (FcLeucine) and pyruvate (FCpyruvate) to mitochondrial acetyl-CoA formation by nuclear magnetic resonance and (ii) global protein fractional synthesis (FSR) by gas chromatography-mass spectrometry. Immature mixed breed Yorkshire male piglets (n = 22) were divided into four groups based on loading status (8 hours of normal circulation or ECMO) and intracoronary infusion [13C6,15N]-L-leucine (3.7 mM) alone or with [2-13C]-pyruvate (7.4 mM). ECMO decreased pulse pressure and correspondingly lowered myocardial oxygen consumption (~ 40%, n = 5), indicating decreased overall mitochondrial oxidative metabolism. However, FcLeucine was maintained and myocardial protein FSR was marginally increased. Pyruvate addition decreased tissue leucine enrichment, FcLeucine, and Fc for endogenous substrates as well as protein FSR. Conclusion: The heart under ECMO shows reduced oxidative metabolism of substrates, including amino acids, while maintaining (i) metabolic flexibility indicated by ability to respond to pyruvate, and (ii) a normal or increased capacity for global protein synthesis, suggesting an improved protein balance.

  8. Microbial activity catalyzes oxygen transfer in membrane-aerated nitritating biofilm reactors

    DEFF Research Database (Denmark)

    Pellicer i Nàcher, Carles; Domingo Felez, Carlos; Lackner, Susanne

    2013-01-01

    The remarkable oxygen transfer efficiencies attainable in membrane-aerated biofilm reactors (MABRs) are expected to favor their prompt industrial implementation. However, tests in clean water, currently used for the estimation of their oxygen transfer potential, lead to wrong estimates once biofilm...... is present, significantly complicating reactor modelling and control. This study shows for the first time the factors affecting oxygen mass transfer across membranes during clean water tests and reactor operation via undisturbed microelectrode inspection and bulk measurements. The mass transfer resistance...... of the liquid boundary layer developed at the membrane-liquid interface during clean water tests accounted for two thirds of the total mass transfer resistance, suggesting a strong underestimation of the oxygen transfer rates when it is absent (e.g. after biofilm growth). Reactor operation to attain partial...

  9. Hybrid membrane using polyethersulfone-modification of multiwalled carbon nanotubes with silane agent to enhance high performance oxygen separation

    Directory of Open Access Journals (Sweden)

    Tutuk Djoko Kusworo

    2014-04-01

    Full Text Available Mixed matrix membrane comprising carbon nanotubes embedded in polymer matrix have become one of the emerging technologies. This study was investigated in order to study the effect of silane agent modification towards carbon nanotubes (CNT surface at different concentration on oxygen enrichment performances of asymmetric mixed matrix membrane. The modified carbon nanotubes were prepared by treating the carbon nanotubes with chemical modification using Dynasylan Ameo (DA silane agent to allow PES chains to be grafted on carbon nanotubes surface. The results from the FESEM, DSC and FTIR analysis confirmed that chemical modification on carbon nanotubes surface had taken place. Sieve-in-a-cage’ morphology observed shows the poor adhesion between polymer and unmodified CNT. The gas separation performance of the asymmetric flat sheet mixed matrix membranes with modified CNT were relatively higher compared to the unmodified CNT. Hence, coated hollow fiber mixed matrix membrane with chemical modification on CNT surface using (3-aminopropyl-triethoxy methyl silane agent can potentially enhance the gas separation performance of O2 and N2.

  10. Oxygen permeation through Nafion 117 membrane and its impact on efficiency of polymer membrane ethanol fuel cell

    Science.gov (United States)

    Jablonski, Andrzej; Kulesza, Pawel J.; Lewera, Adam

    2011-05-01

    We investigate oxygen permeation through Nafion 117 membrane in a direct ethanol fuel cell and elucidate how it affects the fuel cell efficiency. An obvious symptom of oxygen permeation is the presence of significant amounts of acetaldehyde and acetic acid in the mixture leaving anode when no current was drawn from the fuel cell (i.e. under the open circuit conditions). This parasitic process severely lowers efficiency of the fuel cell because ethanol is found to be directly oxidized on the surface of catalyst by oxygen coming through membrane from cathode in the absence of electric current flowing in the external circuit. Three commonly used carbon-supported anode catalysts are investigated, Pt, Pt/Ru and Pt/Sn. Products of ethanol oxidation are determined qualitatively and quantitatively at open circuit as a function of temperature and pressure, and we aim at determining whether the oxygen permeation or the catalyst's activity limits the parasitic ethanol oxidation. Our results strongly imply the need to develop more selective membranes that would be less oxygen permeable.

  11. Enhancing oxygen transport through Mixed-Ionic-and-Electronic-Conducting ceramic membranes

    Science.gov (United States)

    Yu, Anthony S.

    Ceramic membranes based on Mixed-Ionic-and-Electronic-Conducting (MIEC) oxides are capable of separating oxygen from air in the presence of an oxygen partial-pressure gradient. These MIEC membranes show great promise for oxygen consuming industrial processes, such as the production of syngas from steam reforming of natural gas (SRM), as well as for electricity generation in Solid Oxide Fuel Cells (SOFC). For both applications, the overall performance is dictated by the rate of oxygen transport across the membrane. Oxygen transport across MIEC membranes is composed of a bulk oxygen-ion diffusion process and surface processes, such as surface reactions and adsorption/desorption of gaseous reactants/products. The main goal of this thesis was to determine which process is rate-limiting in order to significantly enhance the overall rate of oxygen transport in MIEC membrane systems. The rate-limiting step was determined by evaluating the total resistance to oxygen transfer, Rtot. Rtot is the sum of a bulk diffusion resistance in the membrane itself, Rb, and interfacial loss components, Rs. Rb is a function of the membrane's ionic conductivity and thickness, while Rs arises primarily from slow surface-exchange kinetics that cause the P(O2) at the surfaces of the membrane to differ from the P(O 2) in the adjacent gas phases. Rtot can be calculated from the Nernst potential across the membrane and the measured oxygen flux. The rate-limiting process can be determined by evaluating the relative contributions of the various losses, Rs and Rb, to Rtot. Using this method, this thesis demonstrates that for most membrane systems, Rs is the dominating factor. In the development of membrane systems with high oxygen transport rates, thin membranes with high ionic conductivities are required to achieve fast bulk oxygen-ion diffusion. However, as membrane thickness is decreased, surface reaction kinetics become more important in determining the overall transport rate. The two

  12. Membrane alternatives in worlds without oxygen: Creation of an azotosome.

    Science.gov (United States)

    Stevenson, James; Lunine, Jonathan; Clancy, Paulette

    2015-02-01

    The lipid bilayer membrane, which is the foundation of life on Earth, is not viable outside of biology based on liquid water. This fact has caused astronomers who seek conditions suitable for life to search for exoplanets within the "habitable zone," the narrow band in which liquid water can exist. However, can cell membranes be created and function at temperatures far below those at which water is a liquid? We take a step toward answering this question by proposing a new type of membrane, composed of small organic nitrogen compounds, that is capable of forming and functioning in liquid methane at cryogenic temperatures. Using molecular simulations, we demonstrate that these membranes in cryogenic solvent have an elasticity equal to that of lipid bilayers in water at room temperature. As a proof of concept, we also demonstrate that stable cryogenic membranes could arise from compounds observed in the atmosphere of Saturn's moon, Titan, known for the existence of seas of liquid methane on its surface.

  13. Radiation hardness of silicon detectors manufactured on epitaxial material and FZ bulk enriched with oxygen, carbon, tin and platinum

    CERN Document Server

    Ruzin, A; Glaser, M; Lemeilleur, F; Talamonti, R; Watts, S; Zanet, A

    1999-01-01

    Recent results on the radiation hardness of silicon detectors fabricated on epitaxial and float zone bulk silicon enriched by various impurities, such as carbon, oxygen, tin and platinum are reported. A new methodology of measurements of electrical properties of the devices has been utilized in the experiment. It has been shown that in the case of irradiation by protons, oxygen enriched silicon has better radiation hardness than standard float zone silicon. The carbon enriched silicon detectors, on the other hand, exhibited significantly inferior radiation hardness compared to standard detectors. This study shows for the first time, a violation of the widely used normalization technique of the various particle irradiations by NIEL coefficients. The study has been carried out in the framework of the RD48 (ROSE) collaboration, which studies the radiation hardening of silicon detectors. (5 refs).

  14. Oxygen Transport Membrane Reactors for Oxy-Fuel Combustion and Carbon Capture Purposes

    Science.gov (United States)

    Falkenstein-Smith, Ryan L.

    This thesis investigates oxygen transport membrane reactors (OTMs) for the application of oxy-fuel combustion. This is done by evaluating the material properties and oxygen permeability of different OTM compositions subjected to a variety of operating conditions. The scope of this work consists of three components: (1) evaluate the oxygen permeation capabilities of perovskite-type materials for the application of oxy-fuel combustion; (2) determine the effects of dual-phase membrane compositions on the oxygen permeation performance and membrane characteristics; and (3) develop a new method for estimating the oxygen permeation performance of OTMs utilized for the application of oxy-fuel combustion. SrSc0.1Co0.9O3-delta (SSC) is selected as the primary perovskite-type material used in this research due to its reported high ionic and electronic conductive properties and chemical stability. SSC's oxygen ion diffusivity is investigated using a conductivity relaxation technique and thermogravimetric analysis. Material properties such as chemical structure, morphology, and ionic and electronic conductivity are examined by X-ray diffraction (XRD), Scanning Electron Microscope (SEM), and conductivity testing using a four-probe method, respectively. Oxygen permeation tests study the oxygen permeability OTMs under modified membrane temperatures, sweeping gas flow rates, sweeping gas compositions, membrane configurations, and membrane compositions. When utilizing a pure CO2 sweeping gas, the membrane composition was modified with the addition of Sm0.2Ce0.8O1.9-delta (SDC) at varying wt.% to improve the membranes mechanical stability. A newly developed method to evaluate the oxygen permeation performance of OTMs is also presented by fitting OTM's oxygen permeability to the methane fraction in the sweeping gas composition. The fitted data is used to estimate the overall performance and size of OTMs utilized for the application of oxy-fuel combustion. The findings from this

  15. Developmental distribution of the plasma membrane-enriched proteome in the maize primary root growth zone

    Directory of Open Access Journals (Sweden)

    Zhe eZhang

    2013-03-01

    Full Text Available Within the growth zone of the maize primary root, there are well-defined patterns of spatial and temporal organization of cell division and elongation. However, the processes underlying this organization remain poorly understood. To gain additional insights into the differences amongst the defined regions, we performed a proteomic analysis focusing on fractions enriched for plasma membrane (PM proteins. The PM is the interface between the plant cell and the apoplast and/or extracellular space. As such, it is a key structure involved in the exchange of nutrients and other molecules as well as in the integration of signals that regulate growth and development. Despite the important functions of PM-localized proteins in mediating these processes, a full understanding of dynamic changes in PM proteomes is often impeded by low relative concentrations relative to total proteins. Using a relatively simple strategy of treating microsomal fractions with Brij-58 detergent to enrich for PM proteins, we compared the developmental distribution of proteins within the root growth zone which revealed a number of previously known as well as novel proteins with interesting patterns of abundance. For instance, the quantitative proteomic analysis detected a gradient of PM aquaporin proteins similar to that previously reported using immunoblot analyses, confirming the veracity of this strategy. Cellulose synthases increased in abundance with increasing distance from the root apex, consistent with expected locations of cell wall deposition. The similar distribution pattern for Brittle-stalk-2-like protein 3 implicate that this protein may also have cell wall related functions. These results show that the simplified PM enrichment method previously demonstrated in Arabidopsis can be successfully applied to completely unrelated plant tissues and provide insights into differences in the PM proteome throughout growth and development zones of the maize primary root.

  16. Developmental distribution of the plasma membrane-enriched proteome in the maize primary root growth zone.

    Science.gov (United States)

    Zhang, Zhe; Voothuluru, Priyamvada; Yamaguchi, Mineo; Sharp, Robert E; Peck, Scott C

    2013-01-01

    Within the growth zone of the maize primary root, there are well-defined patterns of spatial and temporal organization of cell division and elongation. However, the processes underlying this organization remain poorly understood. To gain additional insights into the differences amongst the defined regions, we performed a proteomic analysis focusing on fractions enriched for plasma membrane (PM) proteins. The PM is the interface between the plant cell and the apoplast and/or extracellular space. As such, it is a key structure involved in the exchange of nutrients and other molecules as well as in the integration of signals that regulate growth and development. Despite the important functions of PM-localized proteins in mediating these processes, a full understanding of dynamic changes in PM proteomes is often impeded by low relative concentrations relative to total proteins. Using a relatively simple strategy of treating microsomal fractions with Brij-58 detergent to enrich for PM proteins, we compared the developmental distribution of proteins within the root growth zone which revealed a number of previously known as well as novel proteins with interesting patterns of abundance. For instance, the quantitative proteomic analysis detected a gradient of PM aquaporin proteins similar to that previously reported using immunoblot analyses, confirming the veracity of this strategy. Cellulose synthases increased in abundance with increasing distance from the root apex, consistent with expected locations of cell wall deposition. The similar distribution pattern for Brittle-stalk-2-like protein implicates that this protein may also have cell wall related functions. These results show that the simplified PM enrichment method previously demonstrated in Arabidopsis can be successfully applied to completely unrelated plant tissues and provide insights into differences in the PM proteome throughout growth and development zones of the maize primary root.

  17. Oxygen transport membranes for biomass gasification and cement industry

    OpenAIRE

    Cheng, Shiyang; Hendriksen, Peter Vang; Kaiser, Andreas; Søgaard, Martin

    2015-01-01

    I dette projekt er udviklet keramiske ilt-membraner til anvendelse ved fremstilling af ren ilt. Membranerne egner sig endvidere til at levere ilt til en række høj-temperatur processer så som ilt-blæst termisk forgasning af biomasse, cement fremstilling og diverse ”oxyfuel” processer til omsætning af kul med CO2-indfagning. De udviklede membraner er alle baseret på Gd0.1Ce0.9O1.95-δ (GCO). Betydningen af diverse substituenter (f.eks. Pr og Co), der kan øge materialets elektronledningsevne, og ...

  18. Prospective longitudinal evaluation of lung function during the first year of life after extracorporeal membrane oxygenation.

    Science.gov (United States)

    Hofhuis, Ward; Hanekamp, Manon N; Ijsselstijn, Hanneke; Nieuwhof, Eveline M; Hop, Wim C J; Tibboel, Dick; de Jongste, Johan C; Merkus, Peter J F M

    2011-03-01

    To collect longitudinal data on lung function in the first year of life after extracorporeal membrane oxygenation and to evaluate relationships between lung function and perinatal factors. Longitudinal data on lung function in the first year of life after extracorporeal membrane oxygenation are lacking. Prospective longitudinal cohort study. Outpatient clinic of a tertiary level pediatric hospital. The cohort consisted of 64 infants; 33 received extracorporeal membrane oxygenation for meconium aspiration syndrome, 14 for congenital diaphragmatic hernia, four for sepsis, six for persistent pulmonary hypertension of the neonate, and seven for respiratory distress syndrome of infancy. Evaluation was at 6 mos and 12 mos; 39 infants were evaluated at both time points . None. Functional residual capacity and forced expiratory flow at functional residual capacity were measured and expressed as z score. Mean (sem) functional residual capacities in z score were 0.0 (0.2) and 0.2 (0.2) at 6 mos and 12 mos, respectively. Mean (sem) forced expiratory flow was significantly below average (z score = 0) (p capacity significantly above normal: mean (sem) z score = 1.2 (0.5). Infants treated with extracorporeal membrane oxygenation have normal lung volumes and stable forced expiratory flows within normal range, although below average, within the first year of life. There is reason to believe, therefore, that extracorporeal membrane oxygenation either ameliorates the harmful effects of mechanical ventilation or somehow preserves lung function in the very ill neonate.

  19. Oxygen- and Nitrogen-Enriched 3D Porous Carbon for Supercapacitors of High Volumetric Capacity.

    Science.gov (United States)

    Li, Jia; Liu, Kang; Gao, Xiang; Yao, Bin; Huo, Kaifu; Cheng, Yongliang; Cheng, Xiaofeng; Chen, Dongchang; Wang, Bo; Sun, Wanmei; Ding, Dong; Liu, Meilin; Huang, Liang

    2015-11-11

    Efficient utilization and broader commercialization of alternative energies (e.g., solar, wind, and geothermal) hinges on the performance and cost of energy storage and conversion systems. For now and in the foreseeable future, the combination of rechargeable batteries and electrochemical capacitors remains the most promising option for many energy storage applications. Porous carbonaceous materials have been widely used as an electrode for batteries and supercapacitors. To date, however, the highest specific capacitance of an electrochemical double layer capacitor is only ∼200 F/g, although a wide variety of synthetic approaches have been explored in creating optimized porous structures. Here, we report our findings in the synthesis of porous carbon through a simple, one-step process: direct carbonization of kelp in an NH3 atmosphere at 700 °C. The resulting oxygen- and nitrogen-enriched carbon has a three-dimensional structure with specific surface area greater than 1000 m(2)/g. When evaluated as an electrode for electrochemical double layer capacitors, the porous carbon structure demonstrated excellent volumetric capacitance (>360 F/cm(3)) with excellent cycling stability. This simple approach to low-cost carbonaceous materials with unique architecture and functionality could be a promising alternative to fabrication of porous carbon structures for many practical applications, including batteries and fuel cells.

  20. Thermodynamic Analysis of Oxygen-Enriched Direct Smelting of Jamesonite Concentrate

    Science.gov (United States)

    Zhang, Zhong-Tang; Dai, Xi; Zhang, Wen-Hai

    2017-12-01

    Thermodynamic analysis of oxygen-enriched direct smelting of jamesonite concentrate is reported in this article. First, the occurrence state of lead, antimony and other metallic elements in the smelting process was investigated theoretically. Then, the verification test was carried out. The results indicate that lead and antimony mainly exist in the alloy in the form of metallic lead and metallic antimony. Simultaneously, lead and antimony were also oxidized into the slag in the form of lead-antimony oxide. Iron and copper could be oxidized into the slag in the form of oxides in addition to combining with antimony in the alloy, while zinc was mainly oxidized into the slag in the form of zinc oxide. The verification test indicates that the main phases in the alloy contain metallic lead, metallic antimony and a small amount of Cu2Sb, FeSb2 intermetallic compounds, and the slag is mainly composed of kirschsteinite, fayalite and zinc oxide, in agreement with the thermodynamic analysis.

  1. Significant social events and increasing use of life-sustaining treatment: trend analysis using extracorporeal membrane oxygenation as an example.

    Science.gov (United States)

    Chen, Yen-Yuan; Chen, Likwang; Huang, Tien-Shang; Ko, Wen-Je; Chu, Tzong-Shinn; Ni, Yen-Hsuan; Chang, Shan-Chwen

    2014-03-04

    Most studies have examined the outcomes of patients supported by extracorporeal membrane oxygenation as a life-sustaining treatment. It is unclear whether significant social events are associated with the use of life-sustaining treatment. This study aimed to compare the trend of extracorporeal membrane oxygenation use in Taiwan with that in the world, and to examine the influence of significant social events on the trend of extracorporeal membrane oxygenation use in Taiwan. Taiwan's extracorporeal membrane oxygenation uses from 2000 to 2009 were collected from National Health Insurance Research Dataset. The number of the worldwide extracorporeal membrane oxygenation cases was mainly estimated using Extracorporeal Life Support Registry Report International Summary July 2012. The trend of Taiwan's crude annual incidence rate of extracorporeal membrane oxygenation use was compared with that of the rest of the world. Each trend of extracorporeal membrane oxygenation use was examined using joinpoint regression. The measurement was the crude annual incidence rate of extracorporeal membrane oxygenation use. Each of the Taiwan's crude annual incidence rates was much higher than the worldwide one in the same year. Both the trends of Taiwan's and worldwide crude annual incidence rates have significantly increased since 2000. Joinpoint regression selected the model of the Taiwan's trend with one joinpoint in 2006 as the best-fitted model, implying that the significant social events in 2006 were significantly associated with the trend change of extracorporeal membrane oxygenation use following 2006. In addition, significantly social events highlighted by the media are more likely to be associated with the increase of extracorporeal membrane oxygenation use than being fully covered by National Health Insurance. Significant social events, such as a well-known person's successful extracorporeal membrane oxygenation use highlighted by the mass media, are associated with the use of

  2. Severe hypoxemia during veno-venous extracorporeal membrane oxygenation: exploring the limits of extracorporeal respiratory support

    Directory of Open Access Journals (Sweden)

    Liane Brescovici Nunes

    2014-03-01

    Full Text Available OBJECTIVE: Veno-venous extracorporeal oxygenation for respiratory support has emerged as a rescue alternative for patients with hypoxemia. However, in some patients with more severe lung injury, extracorporeal support fails to restore arterial oxygenation. Based on four clinical vignettes, the aims of this article were to describe the pathophysiology of this concerning problem and to discuss possibilities for hypoxemia resolution. METHODS: Considering the main reasons and rationale for hypoxemia during veno-venous extracorporeal membrane oxygenation, some possible bedside solutions must be considered: 1 optimization of extracorporeal membrane oxygenation blood flow; 2 identification of recirculation and cannula repositioning if necessary; 3 optimization of residual lung function and consideration of blood transfusion; 4 diagnosis of oxygenator dysfunction and consideration of its replacement; and finally 5 optimization of the ratio of extracorporeal membrane oxygenation blood flow to cardiac output, based on the reduction of cardiac output. CONCLUSION: Therefore, based on the pathophysiology of hypoxemia during veno-venous extracorporeal oxygenation support, we propose a stepwise approach to help guide specific interventions.

  3. Neonatal and pediatric extracorporeal membrane oxygenation in developing Latin American countries.

    Science.gov (United States)

    Kattan, Javier; González, Álvaro; Castillo, Andrés; Caneo, Luiz Fernando

    To review the principles of neonatal-pediatric extracorporeal membrane oxygenation therapy, prognosis, and its establishment in limited resource-limited countries in Latino America. The PubMed database was explored from 1985 up to the present, selecting from highly-indexed and leading Latin American journals, and Extracorporeal Life Support Organization reports. Extracorporeal membrane oxygenation provides "time" for pulmonary and cardiac rest and for recovery. It is used in the neonatal-pediatric field as a rescue therapy for more than 1300 patients with respiratory failure and around 1000 patients with cardiac diseases per year. The best results in short- and long-term survival are among patients with isolated respiratory diseases, currently established as a standard therapy in referral centers for high-risk patients. The first neonatal/pediatric extracorporeal membrane oxygenation Program in Latin America was established in Chile in 2003, which was also the first program in Latin America to affiliate with the Extracorporeal Life Support Organization. New extracorporeal membrane oxygenation programs have been developed in recent years in referral centers in Argentina, Colombia, Brazil, Mexico, Perú, Costa Rica, and Chile, which are currently funding the Latin American Extracorporeal Life Support Organization chapter. The best results in short- and long-term survival are in patients with isolated respiratory diseases. Today extracorporeal membrane oxygenation therapy is a standard therapy in some Latin American referral centers. It is hoped that these new extracorporeal membrane oxygenation centers will have a positive impact on the survival of newborns and children with respiratory or cardiac failure, and that they will be available for an increasing number of patients from this region in the near future. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  4. Neonatal and pediatric extracorporeal membrane oxygenation in developing Latin American countries

    Directory of Open Access Journals (Sweden)

    Javier Kattan

    Full Text Available Abstract Objective: To review the principles of neonatal-pediatric extracorporeal membrane oxygenation therapy, prognosis, and its establishment in limited resource-limited countries in Latino America. Sources: The PubMed database was explored from 1985 up to the present, selecting from highly-indexed and leading Latin American journals, and Extracorporeal Life Support Organization reports. Summary of the findings: Extracorporeal membrane oxygenation provides “time” for pulmonary and cardiac rest and for recovery. It is used in the neonatal-pediatric field as a rescue therapy for more than 1300 patients with respiratory failure and around 1000 patients with cardiac diseases per year. The best results in short- and long-term survival are among patients with isolated respiratory diseases, currently established as a standard therapy in referral centers for high-risk patients. The first neonatal/pediatric extracorporeal membrane oxygenation Program in Latin America was established in Chile in 2003, which was also the first program in Latin America to affiliate with the Extracorporeal Life Support Organization. New extracorporeal membrane oxygenation programs have been developed in recent years in referral centers in Argentina, Colombia, Brazil, Mexico, Perú, Costa Rica, and Chile, which are currently funding the Latin American Extracorporeal Life Support Organization chapter. Conclusions: The best results in short- and long-term survival are in patients with isolated respiratory diseases. Today extracorporeal membrane oxygenation therapy is a standard therapy in some Latin American referral centers. It is hoped that these new extracorporeal membrane oxygenation centers will have a positive impact on the survival of newborns and children with respiratory or cardiac failure, and that they will be available for an increasing number of patients from this region in the near future.

  5. Simplified Enrichment of Plasma Membrane Proteins from Arabidopsis thaliana Seedlings Using Differential Centrifugation and Brij-58 Treatment.

    Science.gov (United States)

    Collins, Carina A; Leslie, Michelle E; Peck, Scott C; Heese, Antje

    2017-01-01

    The plasma membrane (PM) forms a barrier between a plant cell and its environment. Proteins at this subcellular location play diverse and complex roles, including perception of extracellular signals to coordinate cellular changes. Analyses of PM proteins, however, are often limited by the relatively low abundance of these proteins in the total cellular protein pool. Techniques traditionally used for enrichment of PM proteins are time consuming, tedious, and require extensive optimization. Here, we provide a simple and reproducible enrichment procedure for PM proteins from Arabidopsis thaliana seedlings starting from total microsomal membranes isolated by differential centrifugation. To enrich for PM proteins, total microsomes are treated with the nonionic detergent Brij-58 to decrease the abundance of contaminating organellar proteins. This protocol combined with the genetic resources available in Arabidopsis provides a powerful tool that will enhance our understanding of proteins at the PM.

  6. Annexins as organizers of cholesterol- and sphingomyelin-enriched membrane microdomains in Niemann-Pick type C disease.

    Science.gov (United States)

    Domon, Magdalena; Nasir, Mehmet Nail; Matar, Gladys; Pikula, Slawomir; Besson, Françoise; Bandorowicz-Pikula, Joanna

    2012-06-01

    Growing evidence suggests that membrane microdomains enriched in cholesterol and sphingomyelin are sites for numerous cellular processes, including signaling, vesicular transport, interaction with pathogens, and viral infection, etc. Recently some members of the annexin family of conserved calcium and membrane-binding proteins have been recognized as cholesterol-interacting molecules and suggested to play a role in the formation, stabilization, and dynamics of membrane microdomains to affect membrane lateral organization and to attract other proteins and signaling molecules onto their territory. Furthermore, annexins were implicated in the interactions between cytosolic and membrane molecules, in the turnover and storage of cholesterol and in various signaling pathways. In this review, we focus on the mechanisms of interaction of annexins with lipid microdomains and the role of annexins in membrane microdomains dynamics including possible participation of the domain-associated forms of annexins in the etiology of human lysosomal storage disease called Niemann-Pick type C disease, related to the abnormal storage of cholesterol in the lysosome-like intracellular compartment. The involvement of annexins and cholesterol/sphingomyelin-enriched membrane microdomains in other pathologies including cardiac dysfunctions, neurodegenerative diseases, obesity, diabetes mellitus, and cancer is likely, but is not supported by substantial experimental observations, and therefore awaits further clarification.

  7. Development of metal catalyst impregnation technology for membrane-based oxygen removal system

    International Nuclear Information System (INIS)

    Kim, Mun Soo; Lee, Doo Ho; Kang, Duk Won

    2005-01-01

    Dissolved oxygen(DO) is a primary cause of PWSCC and its content in reactor coolant system in NPPs has been strictly controlled by various DO removal methods. There are several removal methods of DO, such as vacuum degasification, thermal deaeration, and reductive removal by oxygen scavengers. Although the operation principles of vacuum degasification and thermal deaeration are simple, these methods require a lot of energy for operation and show lower efficiency. And these methods have a few handicaps such as temperature, pH, toxicity, high cost of installation and so on. For the purpose of developing the best method for DO removal from make-up water storage tank, it is necessary to overcome the disadvantages of hydrazine treatment. From this point of view, membrane-based oxygen removal system (MORS) has many advantages than other methods for example, friendly environmental process, versatility of operation conditions with high temperature and low pressure, small space, low cost, etc. Recently de-gassing membrane is widely used in power plant's feed water system for DO removal. De-gassing membrane has some advantages; it removes other dissolved gases such as CO2, N2, as well as O2, and is more economical than Catalytic resin-based Oxygen Removal System. In this study, to obtain better efficiency of MORS, we modified the polypropylene (PP) hollow fiber membrane by plasma treatment and ion beam irradiation supported platinum(Pt), palladium(Pd) as metal catalyst on the surface of the membrane

  8. A novel CO>2- and SO>2-tolerant dual phase composite membrane for oxygen separation

    DEFF Research Database (Denmark)

    Cheng, Shiyang; Søgaard, Martin; Han, Li

    2015-01-01

    A novel dual phase composite oxygen membrane (Al0.02Ga0.02Zn0.96O1.02 – Gd0.1Ce0.9O1.95-δ) was successfully prepared and tested. The membrane shows chemical stability against CO2 and SO2, and a stable oxygen permeation over 300 hours in CO2 was demonstrated. ZnO is cheap and non-toxic...... and is therefore highly advantageous compared to other common materials used for the purpose....

  9. Numerical simulation of ion transport membrane reactors: Oxygen permeation and transport and fuel conversion

    KAUST Repository

    Hong, Jongsup

    2012-07-01

    Ion transport membrane (ITM) based reactors have been suggested as a novel technology for several applications including fuel reforming and oxy-fuel combustion, which integrates air separation and fuel conversion while reducing complexity and the associated energy penalty. To utilize this technology more effectively, it is necessary to develop a better understanding of the fundamental processes of oxygen transport and fuel conversion in the immediate vicinity of the membrane. In this paper, a numerical model that spatially resolves the gas flow, transport and reactions is presented. The model incorporates detailed gas phase chemistry and transport. The model is used to express the oxygen permeation flux in terms of the oxygen concentrations at the membrane surface given data on the bulk concentration, which is necessary for cases when mass transfer limitations on the permeate side are important and for reactive flow modeling. The simulation results show the dependence of oxygen transport and fuel conversion on the geometry and flow parameters including the membrane temperature, feed and sweep gas flow, oxygen concentration in the feed and fuel concentration in the sweep gas. © 2012 Elsevier B.V.

  10. CESAR: conventional ventilatory support vs extracorporeal membrane oxygenation for severe adult respiratory failure

    Directory of Open Access Journals (Sweden)

    Mugford Miranda

    2006-12-01

    Full Text Available Abstract Background An estimated 350 adults develop severe, but potentially reversible respiratory failure in the UK annually. Current management uses intermittent positive pressure ventilation, but barotrauma, volutrauma and oxygen toxicity can prevent lung recovery. An alternative treatment, extracorporeal membrane oxygenation, uses cardio-pulmonary bypass technology to temporarily provide gas exchange, allowing ventilator settings to be reduced. While extracorporeal membrane oxygenation is proven to result in improved outcome when compared to conventional ventilation in neonates with severe respiratory failure, there is currently no good evidence from randomised controlled trials to compare these managements for important clinical outcomes in adults, although evidence from case series is promising. Methods/Design The aim of the randomised controlled trial of Conventional ventilatory support vs extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR is to assess whether, for patients with severe, but potentially reversible, respiratory failure, extracorporeal membrane oxygenation will increase the rate of survival without severe disability ('confined to bed' and 'unable to wash or dress' by six months post-randomisation, and be cost effective from the viewpoints of the NHS and society, compared to conventional ventilatory support. Following assent from a relative, adults (18–65 years with severe, but potentially reversible, respiratory failure (Murray score ≥ 3.0 or hypercapnea with pH Discussion Analysis will be based on intention to treat. A concurrent economic evaluation will also be performed to compare the costs and outcomes of both treatments.

  11. Nutrient utilization and oxygen production by Chlorella Vulgaris in a hybrid membrane bioreactor and algal membrane photobioreactor system

    KAUST Repository

    Najm, Yasmeen Hani Kamal

    2017-02-17

    This work studied oxygen production and nutrient utilization by Chlorella Vulgaris at different organic/inorganic carbon (OC/IC) and ammonium/nitrate (NH4+-N/NO3--N) ratios to design a hybrid aerobic membrane bioreactor (MBR) and membrane photobioreactor (MPBR) system. Specific oxygen production by C. vulgaris was enough to support the MBR if high growth is accomplished. Nearly 100% removal (or utilization) of PO43--P and IC was achieved under all conditions tested. Optimal growth was achieved at mixotrophic carbon conditions (0.353 d-1) and the highest NH4+-N concentration (0.357 d-1), with preferable NH4+-N utilization rather than NO3--N. The results indicate the potential of alternative process designs to treat domestic wastewater by coupling the hybrid MBR - MPBR systems.

  12. Nutrient utilization and oxygen production by Chlorella Vulgaris in a hybrid membrane bioreactor and algal membrane photobioreactor system

    KAUST Repository

    Najm, Yasmeen Hani Kamal; Jeong, Sanghyun; Leiknes, TorOve

    2017-01-01

    This work studied oxygen production and nutrient utilization by Chlorella Vulgaris at different organic/inorganic carbon (OC/IC) and ammonium/nitrate (NH4+-N/NO3--N) ratios to design a hybrid aerobic membrane bioreactor (MBR) and membrane photobioreactor (MPBR) system. Specific oxygen production by C. vulgaris was enough to support the MBR if high growth is accomplished. Nearly 100% removal (or utilization) of PO43--P and IC was achieved under all conditions tested. Optimal growth was achieved at mixotrophic carbon conditions (0.353 d-1) and the highest NH4+-N concentration (0.357 d-1), with preferable NH4+-N utilization rather than NO3--N. The results indicate the potential of alternative process designs to treat domestic wastewater by coupling the hybrid MBR - MPBR systems.

  13. Coronavirus and influenza virus proteolytic priming takes place in tetraspanin-enriched membrane microdomains.

    Science.gov (United States)

    Earnest, James T; Hantak, Michael P; Park, Jung-Eun; Gallagher, Tom

    2015-06-01

    Coronaviruses (CoVs) and low-pathogenicity influenza A viruses (LP IAVs) depend on target cell proteases to cleave their viral glycoproteins and prime them for virus-cell membrane fusion. Several proteases cluster into tetraspanin-enriched microdomains (TEMs), suggesting that TEMs are preferred virus entry portals. Here we found that several CoV receptors and virus-priming proteases were indeed present in TEMs. Isolated TEMs, when mixed with CoV and LP IAV pseudoparticles, cleaved viral fusion proteins to fusion-primed fragments and potentiated viral transductions. That entering viruses utilize TEMs as a protease source was further confirmed using tetraspanin antibodies and tetraspanin short hairpin RNAs (shRNAs). Tetraspanin antibodies inhibited CoV and LP IAV infections, but their virus-blocking activities were overcome by expressing excess TEM-associated proteases. Similarly, cells with reduced levels of the tetraspanin CD9 resisted CoV pseudoparticle transductions but were made susceptible by overproducing TEM-associated proteases. These findings indicated that antibodies and CD9 depletions interfere with viral proteolytic priming in ways that are overcome by surplus proteases. TEMs appear to be exploited by some CoVs and LP IAVs for appropriate coengagement with cell receptors and proteases. Enveloped viruses use their surface glycoproteins to catalyze membrane fusion, an essential cell entry step. Host cell components prime these viral surface glycoproteins to catalyze membrane fusion at specific times and places during virus cell entry. Among these priming components are proteases, which cleave viral surface glycoproteins, unleashing them to refold in ways that catalyze virus-cell membrane fusions. For some enveloped viruses, these proteases are known to reside on target cell surfaces. This research focuses on coronavirus and influenza A virus cell entry and identifies TEMs as sites of viral proteolysis, thereby defining subcellular locations of virus

  14. Catalytic reforming of methane to syngas in an oxygen-permeative membrane reactor

    Energy Technology Data Exchange (ETDEWEB)

    Urano, Takeshi; Kubo, Keiko; Saito, Tomoyuki; Hitomi, Atsushi, E-mail: turano@jp.tdk.com [Materials and Process Development Center, TDK Corporation 570-2, Matsugashita, Minamihatori, Narita, Chiba 286-8588 (Japan)

    2011-05-15

    For fuel cell applications, partial oxidative reforming of methane to syngas, hydrogen and carbon monoxide, was performed via a dense oxygen-permeative ceramic membrane composed by both ionic and electronic conductive materials. The modification of Ni-based catalyst by noble metals was investigated to increase oxygen permeation flux and decrease carbon deposition during reforming reaction. The role of each component in catalyst was also discussed.

  15. Surface characterization of the chitosan membrane after oxygen plasma treatment and its aging effect

    International Nuclear Information System (INIS)

    Wang Yingjun; Yin Shiheng; Ren Li; Zhao Lianna

    2009-01-01

    Chitosan has received considerable attention for biomedical applications in recent years because of its biocompatibility and biodegradability. In this paper, angle-resolved x-ray photoelectron spectroscopy (ARXPS) was carried out to investigate the chemical groups' spatial orientation on the chitosan membrane surface. Oxygen plasma treatment was also employed to improve the surface hydrophilicity of the chitosan membrane. The results of ARXPS revealed the distribution of surface polar groups, such as-OH and O=CNH 2 toward the membrane bulk, which was the origin of the chitosan membrane surface hydrophobicity. The contact angle measurements and XPS results indicated that oxygen plasma treatment can markedly improve the surface hydrophilicity and surface energy of the chitosan membrane by incorporating oxygen-containing polar groups. With the existence of the aging process, the influence of plasma treatment was not permanent, it faded with storage time. The ARXPS result discovered that the reorientation of polar functional groups generated by plasma treatment toward the membrane bulk was primarily responsible for the aging effect.

  16. [Biocompatibility of poly-L-lactic acid/Bioglass-guided bone regeneration membranes processed with oxygen plasma].

    Science.gov (United States)

    Fang, Wei; Zeng, Shu-Guang; Gao, Wen-Feng

    2015-04-01

    To prepare and characterize a nano-scale fibrous hydrophilic poly-L-lactic acid/ Bioglass (PLLA/BG) composite membrane and evaluate its biocompatibility as a composite membrane for guiding bone regeneration (GBR). PLLA/BG-guided bone regeneration membrane was treated by oxygen plasma to improved its hydrophilicity. The growth of MG-63 osteoblasts on the membrane was observed using Hoechst fluorescence staining, and the biocompatibility of the membrane was evaluated by calculating the cells adhesion rate and proliferation rate. Osteogenesis of MG-63 cells was assessed by detecting alkaline phosphatase (ALP), and the formation of calcified nodules and cell morphology changes were observed using scanning electron microscope (SEM). The cell adhesion rates of PLLA/BG-guided bone regeneration membrane treated with oxygen plasma were (30.570±0.96)%, (47.27±0.78)%, and (66.78±0.69)% at 1, 3, and 6 h, respectively, significantly higher than those on PLLA membrane and untreated PLLA/BG membrane (Pmembranes increased with time, but highest on oxygen plasma-treated PLLA/BG membrane (Pplasma treatment of the PLLA/BG membrane promoted cell adhesion. The membranes with Bioglass promoted the matrix secretion of the osteoblasts. Under SEM, the formation of calcified nodules and spindle-shaped cell morphology were observed on oxygen plasma-treated PLLA/BG membrane. Oxygen plasma-treated PLLA/BG composite membrane has good biocompatibility and can promote adhesion, proliferation and osteogenesis of the osteoblasts.

  17. Measurement of Soot Volume Fraction and Temperature for Oxygen-Enriched Ethylene Combustion Based on Flame Image Processing

    Directory of Open Access Journals (Sweden)

    Weijie Yan

    2017-05-01

    Full Text Available A method for simultaneously visualizing the two-dimensional distributions of temperature and soot volume fraction in an ethylene flame was presented. A single-color charge-coupled device (CCD camera was used to capture the flame image in the visible spectrum considering the broad-response spectrum of the R and G bands of the camera. The directional emissive power of the R and G bands were calibrated and used for measurement. Slightly increased temperatures and reduced soot concentration were predicted in the central flame without self-absorption effects considered, an iterative algorithm was used for eliminating the effect of self-absorption. Nine different cases were presented in the experiment to demonstrate the effects of fuel mass flow rate and oxygen concentration on temperature and soot concentration in three different atmospheres. For ethylene combustion in pure-air atmosphere, as the fuel mass flow rate increased, the maximum temperature slightly decreased, and the maximum soot volume fraction slightly increased. For oxygen fractions of 30%, 40%, and 50% combustion in O2/N2 oxygen-enhanced atmospheres, the maximum flame temperatures were 2276, 2451, and 2678 K, whereas combustion in O2/CO2 atmospheres were 1916, 2322, and 2535 K. The maximum soot volume fractions were 4.5, 7.0, and 9.5 ppm in oxygen-enriched O2/N2 atmosphere and 13.6, 15.3, and 14.8 ppm in oxygen-enriched O2/CO2 atmosphere. Compared with the O2/CO2 atmosphere, combustion in the oxygen-enriched O2/N2 atmosphere produced higher flame temperature and larger soot volume fraction. Preliminary results indicated that this technique is reliable and can be used for combustion diagnosis.

  18. Interactions between oxygen permeation and homogeneous-phase fuel conversion on the sweep side of an ion transport membrane

    KAUST Repository

    Hong, Jongsup

    2013-02-01

    The interactions between oxygen permeation and homogeneous fuel oxidation reactions on the sweep side of an ion transport membrane (ITM) are examined using a comprehensive model, which couples the dependency of the oxygen permeation rate on the membrane surface conditions and detailed chemistry and transport in the vicinity of the membrane. We assume that the membrane surface is not catalytic to hydrocarbon or syngas oxidation. Results show that increasing the sweep gas inlet temperature and fuel concentration enhances oxygen permeation substantially. This is accomplished through promoting oxidation reactions (oxygen consumption) and the transport of the products and reaction heat towards the membrane, which lowers the oxygen concentration and increases the gas temperature near the membrane. Faster reactions at higher fuel concentration and higher inlet gas temperature support substantial fuel conversion and lead to a higher oxygen permeation flux without the contribution of surface catalytic activity. Beyond a certain maximum in the fuel concentration, extensive heat loss to the membrane (and feed side) reduces the oxidation kinetic rates and limits oxygen permeation as the reaction front reaches the membrane. The sweep gas flow rate and channel height have moderate impacts on oxygen permeation and fuel conversion due to the residence time requirements for the chemical reactions and the location of the reaction zone relative to the membrane surface. © 2012 Elsevier B.V.

  19. CESAR: conventional ventilatory support vs extracorporeal membrane oxygenation for severe adult respiratory failure.

    Science.gov (United States)

    Peek, Giles J; Clemens, Felicity; Elbourne, Diana; Firmin, Richard; Hardy, Pollyanna; Hibbert, Clare; Killer, Hilliary; Mugford, Miranda; Thalanany, Mariamma; Tiruvoipati, Ravin; Truesdale, Ann; Wilson, Andrew

    2006-12-23

    An estimated 350 adults develop severe, but potentially reversible respiratory failure in the UK annually. Current management uses intermittent positive pressure ventilation, but barotrauma, volutrauma and oxygen toxicity can prevent lung recovery. An alternative treatment, extracorporeal membrane oxygenation, uses cardio-pulmonary bypass technology to temporarily provide gas exchange, allowing ventilator settings to be reduced. While extracorporeal membrane oxygenation is proven to result in improved outcome when compared to conventional ventilation in neonates with severe respiratory failure, there is currently no good evidence from randomised controlled trials to compare these managements for important clinical outcomes in adults, although evidence from case series is promising. The aim of the randomised controlled trial of Conventional ventilatory support vs extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR) is to assess whether, for patients with severe, but potentially reversible, respiratory failure, extracorporeal membrane oxygenation will increase the rate of survival without severe disability ('confined to bed' and 'unable to wash or dress') by six months post-randomisation, and be cost effective from the viewpoints of the NHS and society, compared to conventional ventilatory support. Following assent from a relative, adults (18-65 years) with severe, but potentially reversible, respiratory failure (Murray score >/= 3.0 or hypercapnea with pH service will minimise by type of conventional treatment centre, age, duration of high pressure ventilation, hypoxia/hypercapnea, diagnosis and number of organs failed, to ensure balance in key prognostic variables. Extracorporeal membrane oxygenation will not be available for patients meeting entry criteria outside the trial. 180 patients will be recruited to have 80% power to be able to detect a one third reduction in the primary outcome from 65% at 5% level of statistical significance

  20. Syndecans reside in sphingomyelin-enriched low-density fractions of the plasma membrane isolated from a parathyroid cell line.

    Directory of Open Access Journals (Sweden)

    Katarzyna A Podyma-Inoue

    Full Text Available BACKGROUND: Heparan sulfate proteoglycans (HSPGs are one of the basic constituents of plasma membranes. Specific molecular interactions between HSPGs and a number of extracellular ligands have been reported. Mechanisms involved in controlling the localization and abundance of HSPG on specific domains on the cell surface, such as membrane rafts, could play important regulatory roles in signal transduction. METHODOLOGY/PRINCIPAL FINDINGS: Using metabolic radiolabeling and sucrose-density gradient ultracentrifugation techniques, we identified [(35S]sulfate-labeled macromolecules associated with detergent-resistant membranes (DRMs isolated from a rat parathyroid cell line. DRM fractions showed high specific radioactivity ([(35S]sulfate/mg protein, implying the specific recruitment of HSPGs to the membrane rafts. Identity of DRM-associated [(35S]sulfate-labeled molecules as HSPGs was confirmed by Western blotting with antibodies that recognize heparan sulfate (HS-derived epitope. Analyses of core proteins by SDS-PAGE revealed bands with an apparent MW of syndecan-4 (30-33 kDa and syndecan-1 (70 kDa suggesting the presence of rafts with various HSPG species. DRM fractions enriched with HSPGs were characterized by high sphingomyelin content and found to only partially overlap with the fractions enriched in ganglioside GM1. HSPGs could be also detected in DRMs even after prior treatment of cells with heparitinase. CONCLUSIONS/SIGNIFICANCE: Both syndecan-1 and syndecan-4 have been found to specifically associate with membrane rafts and their association seemed independent of intact HS chains. Membrane rafts in which HSPGs reside were also enriched with sphingomyelin, suggesting their possible involvement in FGF signaling. Further studies, involving proteomic characterization of membrane domains containing HSPGs might improve our knowledge on the nature of HSPG-ligand interactions and their role in different signaling platforms.

  1. Fabrication of Novel Hydrogel with Berberine-Enriched Carboxymethylcellulose and Hyaluronic Acid as an Anti-Inflammatory Barrier Membrane

    Directory of Open Access Journals (Sweden)

    Yu-Chih Huang

    2016-01-01

    Full Text Available An antiadhesion barrier membrane is an important biomaterial for protecting tissue from postsurgical complications. However, there is room to improve these membranes. Recently, carboxymethylcellulose (CMC incorporated with hyaluronic acid (HA as an antiadhesion barrier membrane and drug delivery system has been reported to provide excellent tissue regeneration and biocompatibility. The aim of this study was to fabricate a novel hydrogel membrane composed of berberine-enriched CMC prepared from bark of the P. amurense tree and HA (PE-CMC/HA. In vitro anti-inflammatory properties were evaluated to determine possible clinical applications. The PE-CMC/HA membranes were fabricated by mixing PE-CMC and HA as a base with the addition of polyvinyl alcohol to form a film. Tensile strength and ultramorphology of the membrane were evaluated using a universal testing machine and scanning electron microscope, respectively. Berberine content of the membrane was confirmed using a UV-Vis spectrophotometer at a wavelength of 260 nm. Anti-inflammatory property of the membrane was measured using a Griess reaction assay. Our results showed that fabricated PE-CMC/HA releases berberine at a concentration of 660 μg/ml while optimal plasticity was obtained at a 30 : 70 PE-CMC/HA ratio. The berberine-enriched PE-CMC/HA had an inhibited 60% of inflammation stimulated by LPS. These results suggest that the PE-CMC/HA membrane fabricated in this study is a useful anti-inflammatory berberine release system.

  2. Applicability of a liquid membrane in enrichment and determination of nickel traces from natural waters

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez-Lledo, F.C.; Diaz-Lopez, I.C. [University of Havana, Department of Analytical Chemistry, Faculty of Chemistry, Havana (Cuba); Galindo-Riano, Maria D.; Garcia-Vargas, M.; Granado-Castro, M.D. [University of Cadiz, Department of Analytical Chemistry, Faculty of Sciences, Cadiz (Spain)

    2007-09-15

    In this work, a bulk liquid membrane method has been applied for Ni enrichment and separation from natural waters. The carrier-mediated transport was accomplished by pyridine-2-acetaldehyde benzoylhydrazone dissolved in toluene as a complexing agent. The preconcentration was achieved through pH control of source and receiving solutions via a counterflow of protons. The main variables were optimized by using a modified simplex technique. High transport efficiencies (101.2 {+-} 1.8-99.7 {+-} 4.2%) were provided by the carrier for nickel ions in a receiving phase of 0.31 mol L{sup -1} nitric acid after 9-13 h depending on sample salinity. The precision of the method was 2.05% (without a saline matrix) and 4.04% (with 40 g L{sup -1} NaCl) at the 95% confidence level and the detection limit of the blank was 0.015 {mu}g L{sup -1} Ni for detection by atomic absorption spectroscopy. The applicability of the method was tested on certified reference and real water samples with successful results, even for saline samples. The relative errors were -0.60% for certified reference materials and ranged from -0.39 to 2.90% and from 0.3 to 11.05% for real samples, obtained by comparison of inductively coupled plasma mass spectrometry and adsorptive cathodic stripping voltammetry measurements, respectively. (orig.)

  3. Verbal and visual-spatial memory problems at adolescent age after neonatal extracorporeal membrane oxygenation

    NARCIS (Netherlands)

    M.J. Madderom (Marlous); F.K. Aarsen (Femke); R.M. Schiller (Raisa); S.J. Gischler (Saskia); A.F.J. van Heijst (Arno); D. Tibboel (Dick); H. IJsselstijn (Hanneke)

    2018-01-01

    markdownabstract__Objectives__ To assess neuropsychological outcome in 17- and 18-year–old neonatal extracorporeal membrane oxygenation survivors. __Design__ A prospective longitudinal follow-up study. __Setting__ Follow-up program at the Erasmus MC-Sophia Children’s Hospital in Rotterdam, The

  4. Non-intubated recovery from refractory cardiogenic shock on percutaneous VA-extracorporeal membrane oxygenation

    NARCIS (Netherlands)

    van Houte, J; Donker, D W; Wagenaar, L J; Slootweg, A P; Kirkels, J H; van Dijk, D

    We report on the use of percutaneous femoral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) in a fully awake, non-intubated and spontaneously breathing patient suffering from acute, severe and refractory cardiogenic shock due to a (sub)acute anterior myocardial infarction. Intensified

  5. Motor performance in five-year-old extracorporeal membrane oxygenation survivors: A population-based study

    NARCIS (Netherlands)

    M.W.G. Nijhuis-van der Sanden (Maria); M.H.M. van der Cammen-van Zijp (Monique); A.J.W.M. Janssen (Anjo); J.J.C.M. Reuser (Jolanda); P. Mazer (Petra); A.F.J. van Heijst (Arno); S.J. Gischler (Saskia); D. Tibboel (Dick); L.A. Kollee

    2009-01-01

    textabstractIntroduction: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a cardio-pulmonary bypass technique to provide life support in acute reversible cardio-respiratory failure when conventional management is not successful. Most neonates receiving ECMO suffer from meconium

  6. In vitro and in vivo phosphorylation of polypeptides in plasma membrane and tonoplast-enriched fractions from barley roots

    International Nuclear Information System (INIS)

    Garbarino, J.E.; Hurkman, W.J.; Tanaka, C.K.; DuPont, F.M.

    1991-01-01

    Phosphorylation of polypeptides in membrane fractions from barley (Hordeum vulgare L. cv CM 72) roots was compared in in vitro and in vivo assays to assess the potential role of protein kinases in modification of membrane transport. Membrane fractions enriched in endoplasmic reticulum, tonoplast, and plasma membrane were isolated using sucrose gradients and the membrane polypeptides separated using sodium dodecyl sulfate polyacrylamide gel electrophoresis. When the membrane fractions were incubated with γ[p 32 P]ATP, phosphorylation occurred almost exclusively in the plasma membrane fraction. Phosphorylation of a band at 38 kilodaltons increased as the concentration of Mg 2+ was decreased from millimolar to micromolar levels. Phosphorylation of bands at 125, 86, 58, 46 and 28 kilodaltons required millimolar Mg 2+ concentrations and was greatly enhanced by Ca 2+ . When roots of intact plants were labeled with [ 32 P]orthophosphate, polypeptides at approximately 135, 166, 90, 46 to 53, 32, 28, and 19 kilodaltons were labeled in the plasma membrane fraction and polypeptides at approximately 73, 66, and 48 kilodaltons were labeled in the tonoplast fraction. Treatment of the roots of intact plants with 150 millimolar NaCl resulted in increased phosphorylation of some polypeptides while treatment with 100 mM NaCl had no effect

  7. (Ce,Gd)O2−δ-based dual phase membranes for oxygen separation

    DEFF Research Database (Denmark)

    Samson, Alfred Junio; Søgaard, Martin; Hendriksen, Peter Vang

    2014-01-01

    and characterized with respect to sinterability, oxygen permeation rate, phase interaction, and microstructure. These factors are important when considering the development of composite membranes with CGO as the oxide ion conducting phase. Composite membranes with relative densities >91% were fabricated using....... The results indicate a promising prospect for further tailoring and optimization of CGO-based composites for application in oxygen separation....

  8. Endoscopic Resection of Tracheal Tumor in an Elderly Woman Under Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Yi-Ying Chiang

    2011-03-01

    Full Text Available Anesthetic management of patients with difficult airway is challenging, especially in patients who present with near total occlusion of the airway. Tracheal tumors occur more frequently in elderly patients who are more prone to hypoxic injury. Reliable ventilation and oxygenation are mandatory for a safe and sound intervention. Herein, we report on a 71-year-old woman with a large tracheal tumor occluding approximately 90% of the tracheal lumen. Extracorporeal membrane oxygenation under local anesthesia was used during electrocautery resection of the tumor because of the possibility of fatal airway collapse due to the degree of occlusion and location of the tumor. After the tumor had been successfully resected by means of bronchoscopy, an endotracheal tube was inserted, and the patient was weaned from extracorporeal membrane oxygenation.

  9. Towards a Biohybrid Lung: Endothelial Cells Promote Oxygen Transfer through Gas Permeable Membranes.

    Science.gov (United States)

    Menzel, Sarah; Finocchiaro, Nicole; Donay, Christine; Thiebes, Anja Lena; Hesselmann, Felix; Arens, Jutta; Djeljadini, Suzana; Wessling, Matthias; Schmitz-Rode, Thomas; Jockenhoevel, Stefan; Cornelissen, Christian Gabriel

    2017-01-01

    In patients with respiratory failure, extracorporeal lung support can ensure the vital gas exchange via gas permeable membranes but its application is restricted by limited long-term stability and hemocompatibility of the gas permeable membranes, which are in contact with the blood. Endothelial cells lining these membranes promise physiological hemocompatibility and should enable prolonged application. However, the endothelial cells increase the diffusion barrier of the blood-gas interface and thus affect gas transfer. In this study, we evaluated how the endothelial cells affect the gas exchange to optimize performance while maintaining an integral cell layer. Human umbilical vein endothelial cells were seeded on gas permeable cell culture membranes and cultivated in a custom-made bioreactor. Oxygen transfer rates of blank and endothelialized membranes in endothelial culture medium were determined. Cell morphology was assessed by microscopy and immunohistochemistry. Both setups provided oxygenation of the test fluid featuring small standard deviations of the measurements. Throughout the measuring range, the endothelial cells seem to promote gas transfer to a certain extent exceeding the blank membranes gas transfer performance by up to 120%. Although the underlying principles hereof still need to be clarified, the results represent a significant step towards the development of a biohybrid lung.

  10. Effect of oxygen enriched combustion and water–diesel emulsion on the performance and emissions of turbocharged diesel engine

    International Nuclear Information System (INIS)

    Liang, Youcai; Shu, Gequn; Wei, Haiqiao; Zhang, Wei

    2013-01-01

    Highlights: • Emulsion is effective to mitigate increased NOx caused by OEC. • OEC and WDE have significant influence on particle mode formation. • OEC and WDE have significant influence on combustion characteristics. • The application potential of combination of OEC and WDE has been proved. - Abstract: Oxygen enriched combustion (OEC) is potential to improve emissions, thermal efficiency and brake power output of diesel engine. The purpose of this investigation is to study whether it is feasible to apply water diesel emulsion to mitigate the increasing NOx caused by OEC with comparable BSFC and power output. Effect of OEC on particle size and number concentration was also analyzed in this paper. Oxygen concentration of intake air varied from 21% to 24% by volume. Water content in tested fuels was 0%, 10%, 20%, and 30% by volume respectively. The result indicated that lower BSFC, higher cylinder pressure and shorter ignition delay were observed when OEC was applied, while opposite trends were found when using WDE. Reduction of PM and NOx can be realized simultaneously by applying OE combined with WDE. Particle number concentration of nucleation mode increases with increasing oxygen concentration, while that of accumulation mode decreases. Optimal operating condition was realized when water content in emulsion was below 20% along with low oxygen enrichment

  11. Apparent Km of mitochondria for oxygen computed from Vmax measured in permeabilized muscle fibers is lower in water enriched in oxygen by electrolysis than injection.

    Science.gov (United States)

    Zoll, Joffrey; Bouitbir, Jamal; Sirvent, Pascal; Klein, Alexis; Charton, Antoine; Jimenez, Liliana; Péronnet, François R; Geny, Bernard; Richard, Ruddy

    2015-01-01

    It has been suggested that oxygen (O2) diffusion could be favored in water enriched in O2 by a new electrolytic process because of O2 trapping in water superstructures (clathrates), which could reduce the local pressure/content relationships for O2 and facilitate O2 diffusion along PO2 gradients. Mitochondrial respiration was compared in situ in saponin-skinned fibers isolated from the soleus muscles of Wistar rats, in solution enriched in O2 by injection or the electrolytic process 1) at an O2 concentration decreasing from 240 µmol/L to 10 µmol/L (132 mmHg to 5 mmHg), with glutamate-malate or N, N, N', N'-tetramethyl-p-phenylenediamine dihydrochloride (TMPD)-ascorbate (with antimycin A) as substrates; and 2) at increasing adenosine diphosphate (ADP) concentration with glutamate-malate as substrate. As expected, maximal respiration decreased with O2 concentration and, when compared to glutamate-malate, the apparent Km O2 of mitochondria for O2 was significantly lower with TMPD-ascorbate with both waters. However, when compared to the water enriched in O2 by injection, the Km O2 was significantly lower with both electron donors in water enriched in O2 by electrolysis. This was not associated with any increase in the sensitivity of mitochondria to ADP; no significant difference was observed for the Km ADP between the two waters. In this experiment, a higher affinity of the mitochondria for O2 was observed in water enriched in O2 by electrolysis than by injection. This observation is consistent with the hypothesis that O2 diffusion can be facilitated in water enriched in O2 by the electrolytic process.

  12. The obtaining and properties of asymmetric ion transport membrane for separating of oxygen from air

    Science.gov (United States)

    Solovieva, A. A.; Kulbakin, I. V.

    2018-04-01

    The bilayer oxygen-permeable membrane, consisting of a thin-film dense composite based on Co3O4 - 36 wt. % Bi2O3, and of a porous ceramic substrate of Co2SiO4, was synthesized and characterized. The way for obtaining of porous ceramic based on cobalt silicate was found, while the microstructure and the mechanical properties of porous ceramic were studied. Layered casting with post-pressing was used to cover the surface of porous support of Co2SiO4 by the Co3O4 - 36 wt. % Bi2O3 - based film. Transport properties of the asymmetric membrane have been studied, the kinetic features of oxygen transport have been established, and the characteristic thickness of the membrane has been estimated. The methods to prevent the high-temperature creep of ion transport membranes based on solid/molten oxides, which are the promising ones for obtaining of pure oxygen from air, are proposed and discussed.

  13. Radiation-induced lipid peroxidation: influence of oxygen concentration and membrane lipid composition

    International Nuclear Information System (INIS)

    Wolters, H.; Tilburg, C.A.M. van; Konings, A.W.T.

    1987-01-01

    Radiation -induced lipid peroxidation phospholipid liposomes was investigated in terms of its dependence on lipid composition and oxygen concentration. Non-peroxidizable lipid incorporated in the liposomes reduced the rate of peroxidation of the peroxidizable phospholipid acyl chains, possibly by restricting the length of chain reactions. The latter effect is believed to be caused by interference of the non-peroxidizable lipids in the bilayer. At low oxygen concentration lipid peroxidation was reduced. The cause of this limited peroxidation may be a reduced number of radical initiation reactions possibly involving oxygen-derived superoxide radicals. Killing of proliferating mammalian cells, irradiated at oxygen concentrations ranging from 0 to 100%, appeared to be independent of the concentration of peroxidizable phospholipids in the cell membranes. This indicates that lipid peroxidation is not the determining process in radiation-induced reproductive cell death. (author)

  14. Oxygen Permeation and Stability Study of (La0.6Ca0.4)0.98(Co0.8Fe0.2)O3-δ Membranes

    DEFF Research Database (Denmark)

    Salehi, Mehdi; Søgaard, Martin; Esposito, Vincenzo

    2017-01-01

    ) was tested. A small decrease in the flux was observed over 48 h in CO2 at 850 °C. SEM examinations of the cross-section of the tested membrane showed that the Ca rich phase in the membrane showed a tendency to migrate to the feed side. Whereas the material shows a CO2 stability superior to that of Sr or Ba......The perovskite-type oxide (La0.6Ca0.4)0.98(Co0.8Fe0.2)O3-δ (LCCF) was investigated for use as oxygen separation membrane. A 25 µm thick dense membrane on a porous LCCF support with a thickness of around 175 µm was prepared by a tape casting and lamination process. The optimum sintering temperature...... of the component was established to be 1050 °C by analysis of microstructures of membranes sintered at different temperatures. Scanning electron microscopy (SEM) examination of cross-sections of the sintered membrane showed that it consisted of two phases, the main phase being enriched in calcium (Ca) and depleted...

  15. Experimental investigation on performance characteristics of a diesel engine using diesel-water emulsion with oxygen enriched air

    Directory of Open Access Journals (Sweden)

    P. Baskar

    2017-03-01

    Full Text Available Diesel engines occupy a crucial position in automobile industry due to their high thermal efficiency and high power to weight ratio. However, they lag behind in controlling air polluting components coming out of the engine exhaust. Therefore, diesel consumption should be analyzed for future energy consumption and this can be primarily controlled by the petroleum fuel substitution techniques for existing diesel engines, which include biodiesel, alcohol-diesel emulsions and diesel water emulsions. Among them the diesel water emulsion is found to be most suitable fuel due to reduction in particulate matter and NOx emission, besides that it also improves the brake thermal efficiency. But the major problem associated with emulsions is the ignition delay, since this is responsible for the power and torque loss. A reduction in NOx emission was observed due to reduction in combustion chamber temperature as the water concentration increases. However the side effect of emulsified diesel is a reduction in power which can be compensated by oxygen enrichment. The present study investigates the effects of oxygen concentration on the performance characteristics of a diesel engine when the intake air is enriched to 27% of oxygen and fueled by 10% of water diesel emulsion. It was found that the brake thermal efficiency was enhanced, combustion characteristics improved and there is also a reduction in HC emissions.

  16. Toward enhanced hydrogen generation from water using oxygen permeating LCF membranes

    KAUST Repository

    Wu, Xiao-Yu

    2015-01-01

    © the Owner Societies. Hydrogen production from water thermolysis can be enhanced by the use of perovskite-type mixed ionic and electronic conducting (MIEC) membranes, through which oxygen permeation is driven by a chemical potential gradient. In this work, water thermolysis experiments were performed using 0.9 mm thick La0.9Ca0.1FeO3-δ (LCF-91) perovskite membranes at 990 °C in a lab-scale button-cell reactor. We examined the effects of the operating conditions such as the gas species concentrations and flow rates on the feed and sweep sides on the water thermolysis rate and oxygen flux. A single step reaction mechanism is proposed for surface reactions, and three-resistance permeation models are derived. Results show that water thermolysis is facilitated by the LCF-91 membrane especially when a fuel is added to the sweep gas. Increasing the gas flow rate and water concentration on the feed side or the hydrogen concentration on the sweep side enhances the hydrogen production rate. In this work, hydrogen is used as the fuel by construction, so that a single-step surface reaction mechanism can be developed and water thermolysis rate parameters can be derived. Both surface reaction rate parameters for oxygen incorporation/dissociation and hydrogen-oxygen reactions are fitted at 990 °C. We compare the oxygen fluxes in water thermolysis and air separation experiments, and identify different limiting steps in the processes involving various oxygen sources and sweep gases for this 0.9 mm thick LCF-91 membrane. In the air feed-inert sweep case, the bulk diffusion and sweep side surface reaction are the two limiting steps. In the water feed-inert sweep case, surface reaction on the feed side dominates the oxygen permeation process. Yet in the water feed-fuel sweep case, surface reactions on both the feed and sweep sides are rate determining when hydrogen concentration in the sweep side is in the range of 1-5 vol%. Furthermore, long term studies show that the surface

  17. Applicability of a Supported Liquid Membrane in the Enrichment and Determination of Cadmium from Complex Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Núria Pont

    2018-04-01

    Full Text Available A supported liquid membrane is developed for the separation of Cd from either high in salinity or acidity aqueous media. The membrane consisted of a durapore (polyvinylidene difluoride polymeric support impregnated with a 0.5 M Aliquat 336 solution in decaline. The effect of carrier concentration, organic solvent and feed and receiving solutions on the metal permeability is studied. This system allows the effective transport of trace levels of Cd through the formation of CdCl42−, which is the predominant species responsible for the extraction process, in both NaCl and HCl solutions. The supported liquid membrane system in a hollow fibre configuration allows the enrichment and separation of trace levels of Cd from spiked seawater samples, facilitating the analytical determination of this toxic metal.

  18. Accelerating the design of molecularly imprinted nanocomposite membranes modified by Au@polyaniline for selective enrichment and separation of ibuprofen

    Science.gov (United States)

    Wu, Xiuling; Wu, Yilin; Dong, Hongjun; Zhao, Juan; Wang, Chen; Zhou, Shi; Lu, Jian; Yan, Yongsheng; Li, He

    2018-01-01

    A novel system for harvesting molecularly imprinted nanocomposite membranes (MINcMs) with Au-modified polyaniline (Au@polyaniline) nanocomposite structure was developed for selective enrichment and separation of ibuprofen. This unique nanocomposite structure obviously enhanced the adsorption capacity, perm-selectivity performance, and regeneration ability of MINcMs. The as-prepared MINcMs showed outstanding adsorption capacity (22.02 mg g-1) of ibuprofen, which was four times higher than that of non-imprinted nanocomposite membranes (NINcMs). Furthermore, the selectivity factor of MINcMs for ibuprofen reached up to 4.67 and the perm-selectivity factor β was about 8.74, which indicated MINcMs had a good selective separation performance of ibuprofen. We envision that this novel synthesis method will open a new direction to manipulation of molecularly imprinted membrane materials and provide a simple yet convenient way to selective separation of ibuprofen.

  19. Successful Use of Extracorporeal Membrane Oxygenation for the Treatment of Cardiogenic Shock due to Scorpion Envenomation

    Directory of Open Access Journals (Sweden)

    Amine Tarmiz

    2017-01-01

    Full Text Available Introduction. The occurrence of a cardiogenic shock is a rare presentation after scorpion envenomation. The treatment includes classically the use of inotropes and specific vasodilators. Case Presentation. We report a case of an 11-year-old boy presenting with cardiogenic shock and pulmonary edema after a scorpion sting. Despite adequate management at the emergency department and intensive care unit, the patient’s hemodynamic status worsened rapidly, justifying his transfer to our department for ventricular mechanical assistance by venoarterial extracorporeal membrane oxygenation. The following outcomes were favorable and the boy was discharged home on day 29 without aftereffects. Conclusion. This is the first report of successful use of extracorporeal membrane oxygenation for the treatment of cardiogenic shock after scorpion envenomation.

  20. Role of Epinephrine and Extracorporeal Membrane Oxygenation in the Management of Ischemic Refractory Ventricular Fibrillation

    Directory of Open Access Journals (Sweden)

    Jason A. Bartos, MD, PhD

    2017-06-01

    Full Text Available Summary: Extracorporeal membrane oxygenation (ECMO is used in cardiopulmonary resuscitation (CPR of refractory cardiac arrest. The authors used a 2 × 2 study design to compare ECMO versus CPR and epinephrine versus placebo in a porcine model of ischemic refractory ventricular fibrillation (VF. Pigs underwent 5 min of untreated VF and 10 min of CPR, and were randomized to receive epinephrine versus placebo for another 35 min. Animals were further randomized to left anterior descending artery (LAD reperfusion at minute 45 with ongoing CPR versus venoarterial ECMO cannulation at minute 45 of CPR and subsequent LAD reperfusion. Four-hour survival was improved with ECMO whereas epinephrine showed no effect. Key Words: advanced cardiopulmonary life support, cardiac arrest, cardiopulmonary resuscitation, ECMO, extracorporeal membrane oxygenation, ischemic refractory ventricular fibrillation, ST-segment elevation myocardial infarction, ventricular fibrillation

  1. Growing experience with extracorporeal membrane oxygenation as a bridge to lung transplantation.

    Science.gov (United States)

    Shafii, Alexis E; Mason, David P; Brown, Chase R; Vakil, Nakul; Johnston, Douglas R; McCurry, Kenneth R; Pettersson, Gosta B; Murthy, Sudish C

    2012-01-01

    Extracorporeal membrane oxygenation (ECMO) is rarely used as a bridge to lung transplantation (BTT) because of its associated morbidity and mortality. However, recent advancements in perfusion technology and critical care have revived interest in this application of ECMO. We retrospectively reviewed our utilization of ECMO as BTT and evaluated our early and midterm results. Nineteen patients were placed on ECMO with the intent to transplant of which 14 (74%) were successfully transplanted. Early and midterm survival of transplanted patients was 75% (1 year) and 63% (3 years), respectively, with the most favorable results observed in interstitial lung disease patients supported in the venovenous configuration. Extracorporeal membrane oxygenation-bridged transplant survival rates were equivalent to nonbridged recipients, but early morbidity and mortality are high and the failure to bridge to transplant is significant. Overall, successfully bridged patients can derive a tangible benefit, albeit with considerable consumption of resources.

  2. Transfusion Associated Hyperkalemia and Cardiac Arrest in an Infant after Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Do Wan Kim

    2015-05-01

    Full Text Available Cardiac arrest associated with hyperkalemia during red blood cell transfusion is a rare but fatal complication. Herein, we report a case of transfusion-associated cardiac arrest following the initiation of extracorporeal membrane oxygenation support in a 9-month old infant. Her serum potassium level was increased to 9.0 mEq/L, soon after the newly primed circuit with pre-stored red blood cell (RBC was started and followed by sudden cardiac arrest. Eventually, circulation was restored and the potassium level decreased to 5.1 mEq/L after 5 min. Extracorporeal membrane oxygenation (ECMO priming is a relatively massive transfusion into a pediatric patient. Thus, to prevent cardiac arrest during blood-primed ECMO in neonates and infants, freshly irradiated and washed RBCs should be used when priming the ECMO circuit, to minimize the potassium concentration. Also, physicians should be aware of all possible complications associated with transfusions during ECMO.

  3. Laminar oxy-fuel diffusion flame supported by an oxygen-permeable-ion-transport membrane

    KAUST Repository

    Hong, Jongsup

    2013-03-01

    A numerical model with detailed gas-phase chemistry and transport was used to predict homogeneous fuel conversion processes and to capture the important features (e.g., the location, temperature, thickness and structure of a flame) of laminar oxy-fuel diffusion flames stabilized on the sweep side of an oxygen permeable ion transport membrane (ITM). We assume that the membrane surface is not catalytic to hydrocarbon or syngas oxidation. It has been demonstrated that an ITM can be used for hydrocarbon conversion with enhanced reaction selectivity such as oxy-fuel combustion for carbon capture technologies and syngas production. Within an ITM unit, the oxidizer flow rate, i.e., the oxygen permeation flux, is not a pre-determined quantity, since it depends on the oxygen partial pressures on the feed and sweep sides and the membrane temperature. Instead, it is influenced by the oxidation reactions that are also dependent on the oxygen permeation rate, the initial conditions of the sweep gas, i.e., the fuel concentration, flow rate and temperature, and the diluent. In oxy-fuel combustion applications, the sweep side is fuel-diluted with CO2, and the entire unit is preheated to achieve a high oxygen permeation flux. This study focuses on the flame structure under these conditions and specifically on the chemical effect of CO2 dilution. Results show that, when the fuel diluent is CO2, a diffusion flame with a lower temperature and a larger thickness is established in the vicinity of the membrane, in comparison with the case in which N2 is used as a diluent. Enhanced OH-driven reactions and suppressed H radical chemistry result in the formation of products with larger CO and H2O and smaller H2 concentrations. Moreover, radical concentrations are reduced due to the high CO2 fraction in the sweep gas. CO2 dilution reduces CH3 formation and slows down the formation of soot precursors, C2H2 and C2H4. The flame location impacts the species diffusion and heat transfer from the

  4. Left Atrial Decompression by Percutaneous Left Atrial Venting Cannula Insertion during Venoarterial Extracorporeal Membrane Oxygenation Support

    Directory of Open Access Journals (Sweden)

    Ha Eun Kim

    2016-06-01

    Full Text Available Patients with venoarterial extracorporeal membrane oxygenation (ECMO frequently suffer from pulmonary edema due to left ventricular dysfunction that accompanies left heart dilatation, which is caused by left atrial hypertension. The problem can be resolved by left atrium (LA decompression. We performed a successful percutaneous LA decompression with an atrial septostomy and placement of an LA venting cannula in a 38-month-old child treated with venoarterial ECMO for acute myocarditis.

  5. Extracorporeal Circulation Using an Extracorporeal Membrane Oxygenation System and an Autotransfusion System

    Directory of Open Access Journals (Sweden)

    Yu. A. Bakhareva

    2010-01-01

    Full Text Available The authors draw attention to the fact that complete cardiopulmonary bypass can be made in the emergency situation in order to perform an extracorporeal membrane oxygenation (ECMO procedure in a 5-year-old boy weighing 15 kg, diagnosed as having Fallot tetrad. By taking into account the technological features of the system for ECMO, there is an additional need for a blood cell separator to be applied.

  6. Adjunctive Therapies During Extracorporeal Membrane Oxygenation to Enhance Multiple Organ Support in Critically Ill Children

    Directory of Open Access Journals (Sweden)

    Marguerite Orsi Canter

    2018-04-01

    Full Text Available Since the advent of extracorporeal membrane oxygenation (ECMO over 40 years ago, there has been increasing interest in the use of the extracorporeal circuit as a platform for providing multiple organ support. In this review, we will examine the evidence for the use of continuous renal replacement therapy, therapeutic plasma exchange, leukopheresis, adsorptive therapies, and extracorporeal liver support in conjunction with ECMO.

  7. Dually Fluorescent Sensing of pH and Dissolved Oxygen Using a Membrane Made from Polymerizable Sensing Monomers

    OpenAIRE

    Tian, Yanqing; Shumway, Bradley R.; Youngbull, A. Cody; Li, Yongzhong; Jen, Alex K.-Y.; Johnson, Roger H.; Meldrum, Deirdre R.

    2010-01-01

    Using a thermal polymerization approach and polymerizable pH and oxygen sensing monomers with green and red emission spectra, respectively, new pH, oxygen, and their dual sensing membranes were prepared using poly(2-hydroxyethyl methacrylate)-co-poly(acrylamide) as a matrix. The sensors were grafted on acrylate-modified quartz glass and characterized under different pH values, oxygen concentrations, ion strengths, temperatures and cell culture media. The pH and oxygen sensors were excited usi...

  8. Enhancement of oxygen transfer and nitrogen removal in a membrane separation bioreactor for domestic wastewater treatment.

    Science.gov (United States)

    Chiemchaisri, C; Yamamoto, K

    2005-01-01

    Biological nitrogen removal in a membrane separation bioreactor developed for on-site domestic wastewater treatment was investigated. The bioreactor employed hollow fiber membrane modules for solid-liquid separation so that the biomass could be completely retained within the system. Intermittent aeration was supplied with 90 minutes on and off cycle to achieve nitrification and denitrification reaction for nitrogen removal. High COD and nitrogen removal of more than 90% were achieved under a moderate temperature of 25 degrees C. As the temperature was stepwise decreased from 25 to 5 degrees C, COD removal in the system could be constantly maintained while nitrogen removal was deteriorated. Nevertheless, increasing aeration supply could enhance nitrification at low temperature with benefit from complete retention of nitrifying bacteria within the system by membrane separation. At low operating temperature range of 5 degrees C, nitrogen removal could be recovered to more than 85%. A mathematical model considering diffusion resistance of limiting substrate into the bio-particle is applied to describe nitrogen removal in a membrane separation bioreactor. The simulation suggested that limitation of the oxygen supply was the major cause of inhibition of nitrification during temperature decrease. Nevertheless, increasing aeration could promote oxygen diffusion into the bio-particle. Sufficient oxygen was supplied to the nitrifying bacteria and the nitrification could proceed. In the membrane separation bioreactor, biomass concentration under low temperature operation was allowed to increase by 2-3 times of that of moderate temperature to compensate for the loss of bacterial activities so that the temperature effect was masked.

  9. Freestanding eggshell membrane-based electrodes for high-performance supercapacitors and oxygen evolution reaction

    Science.gov (United States)

    Geng, Jing; Wu, Hao; Al-Enizi, Abdullah M.; Elzatahry, Ahmed A.; Zheng, Gengfeng

    2015-08-01

    A type of freestanding, light-weight eggshell membrane-based electrode is demonstrated for supercapacitors and for oxygen evolution reaction (OER) catalysis. As a widely available daily waste, eggshell membranes have unique porous three-dimensional grid-like fibrous structures with relatively high surface area and abundant macropores, allowing for effective conjugation of carbon nanotubes and growth of NiCo2O4 nanowire arrays, an effective supercapacitor material and OER catalyst. The three-dimensional fibrous eggshell membrane frameworks with carbon nanotubes offer efficient pathways for charge transport, and the macropores between adjacent fibers are fully accessible for electrolytes and bubble evolution. As a supercapacitor, the eggshell membrane/carbon nanotube/NiCo2O4 electrode shows high specific capacitances at current densities from 1 to 20 A g-1, with excellent capacitance retention (>90%) at 10 A g-1 for over 10 000 cycles. When employed as an OER catalyst, this eggshell membrane-based electrode exhibits an OER onset potential of 1.53 V vs. the reversible hydrogen electrode (RHE), and a stable catalytic current density of 20 mA cm-2 at 1.65 V vs. the RHE.A type of freestanding, light-weight eggshell membrane-based electrode is demonstrated for supercapacitors and for oxygen evolution reaction (OER) catalysis. As a widely available daily waste, eggshell membranes have unique porous three-dimensional grid-like fibrous structures with relatively high surface area and abundant macropores, allowing for effective conjugation of carbon nanotubes and growth of NiCo2O4 nanowire arrays, an effective supercapacitor material and OER catalyst. The three-dimensional fibrous eggshell membrane frameworks with carbon nanotubes offer efficient pathways for charge transport, and the macropores between adjacent fibers are fully accessible for electrolytes and bubble evolution. As a supercapacitor, the eggshell membrane/carbon nanotube/NiCo2O4 electrode shows high specific

  10. Design of a mixed ionic/electronic conducting oxygen transport membrane pilot module

    Energy Technology Data Exchange (ETDEWEB)

    Pfaff, E.M.; Kaletsch, A.; Broeckmann, C. [RWTH Aachen University, IWM, Aachen (Germany)

    2012-03-15

    In the last years, a lot of ceramic materials were developed that, at higher temperatures, have a high electrical conductivity and a high conductivity of oxygen ions. Such mixed ionic/electronic conductors can be used to produce high-purity oxygen. This work focuses on the realization of a pilot membrane module, with BSCF (Ba{sub 0.5}Sr{sub 0.5}Co{sub 0.8}Fe{sub 0.2}O{sub 3-{delta}}) perovskite selected as the membrane material. An amount of 500 kg of powder was industrially fabricated, spray-granulized and pressed into tubes. The best operation conditions concerning energy consumption were calculated, and a module reactor was designed operating at 850 C, with an air pressure of 15-20 bar on the feed site and a low vacuum of about 0.8 bar on the permeate site. Special emphasis was placed on joining alternatives for ceramic tubes in metallic bottoms. A first laboratory module was tested with a membrane area of 1 m{sup 2} and then advanced to a pilot module with 570 tubes and a capability of more than 300 000 L of pure oxygen per day. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. Hemodynamic deterioration during extracorporeal membrane oxygenation weaning in a patient with a total artificial heart.

    Science.gov (United States)

    Hosseinian, Leila; Levin, Matthew A; Fischer, Gregory W; Anyanwu, Anelechi C; Torregrossa, Gianluca; Evans, Adam S

    2015-01-01

    The Total Artificial Heart (Syncardia, Tucson, AZ) is approved for use as a bridge-to-transplant or destination therapy in patients who have irreversible end-stage biventricular heart failure. We present a unique case, in which the inferior vena cava compression by a total artificial heart was initially masked for days by the concurrent placement of an extracorporeal membrane oxygenation cannula. This is the case of a 33-year-old man admitted to our institution with recurrent episodes of ventricular tachycardia requiring emergent total artificial heart and venovenous extracorporeal membrane oxygenation placement. This interesting scenario highlights the importance for critical care physicians to have an understanding of exact anatomical localization of a total artificial heart, extracorporeal membrane oxygenation, and their potential interactions. In total artificial heart patients with hemodynamic compromise or reduced device filling, consideration should always be given to venous inflow compression, particularly in those with smaller body surface area. Transesophageal echocardiogram is a readily available diagnostic tool that must be considered standard of care, not only in the operating room but also in the ICU, when dealing with this complex subpopulation of cardiac patients.

  12. Electrospinning fabrication and oxygen sensing properties of Cu(I) complex-polystyrene composite microfibrous membranes

    Energy Technology Data Exchange (ETDEWEB)

    Wang Liyan, E-mail: wanglykmmc@163.co [Department of Orthodontics, School of Stomatology, Fourth Military Medical University, XiAn (China); Xu Yun [Department of Orthodontics, School of Stomatology, KunMing Medical College, Kunming (China); Lin Zhu [Department of Orthodontics, School of Stomatology, Fourth Military Medical University, XiAn (China); Zhao Ning [Department of Orthodontics, School of Stomatology, West China College, SiChuan University, ChengDu (China); Xu Yanhua [Department of Orthodontics, School of Stomatology, KunMing Medical College, Kunming (China)

    2011-07-15

    In this paper, a phosphorescent Cu(I) complex of [Cu(POP)(ECI-Phen)]BF{sub 4}, where POP=bis[2-(diphenylphosphino)phenyl]ether, and ECI-Phen=1-ethyl-2-(N-ethyl-carbazole-yl-4-)imidazo[4,5-f]1,10-phenanthroline, is incorporated into a polystyrene matrix of polystyrene (PS) to form microfibers membranes. The possibility of using the resulted composite microfibrous membranes as an optical oxygen sensor is explored. Good linearity and short response time are obtained with a sensitivity of 9.8. These results suggest that phosphorescent [Cu(POP)(ECI-Phen)]BF{sub 4} is a promising candidate for oxygen-sensors and PS is an excellent matrix for oxygen sensing material because it owns a large surface-area-to-volume ratio and can supply a homogeneous matrix for probe molecules. Further analysis suggests that the molecular structure of diamine ligand in Cu(I) complexes is critical for sensitivity due to the characteristic electronic structure of excited state Cu(I) complexes. - Highlights: {yields} Cu(I) complex is incorporated into polystyrene matrix to form nanofibers. {yields} Resulted sample exhibit good linearity and short response time. {yields} PS is an excellent matrix for oxygen sensing material for probe molecules. {yields} Molecular structure of diamine ligand is critical for sensitivity.

  13. Electrospinning fabrication and oxygen sensing properties of Cu(I) complex-polystyrene composite microfibrous membranes

    International Nuclear Information System (INIS)

    Wang Liyan; Xu Yun; Lin Zhu; Zhao Ning; Xu Yanhua

    2011-01-01

    In this paper, a phosphorescent Cu(I) complex of [Cu(POP)(ECI-Phen)]BF 4 , where POP=bis[2-(diphenylphosphino)phenyl]ether, and ECI-Phen=1-ethyl-2-(N-ethyl-carbazole-yl-4-)imidazo[4,5-f] 1,10-phenanthroline, is incorporated into a polystyrene matrix of polystyrene (PS) to form microfibers membranes. The possibility of using the resulted composite microfibrous membranes as an optical oxygen sensor is explored. Good linearity and short response time are obtained with a sensitivity of 9.8. These results suggest that phosphorescent [Cu(POP)(ECI-Phen)]BF 4 is a promising candidate for oxygen-sensors and PS is an excellent matrix for oxygen sensing material because it owns a large surface-area-to-volume ratio and can supply a homogeneous matrix for probe molecules. Further analysis suggests that the molecular structure of diamine ligand in Cu(I) complexes is critical for sensitivity due to the characteristic electronic structure of excited state Cu(I) complexes. - Highlights: → Cu(I) complex is incorporated into polystyrene matrix to form nanofibers. → Resulted sample exhibit good linearity and short response time. → PS is an excellent matrix for oxygen sensing material for probe molecules. → Molecular structure of diamine ligand is critical for sensitivity.

  14. Central extracorporeal membrane oxygenation requiring pulmonary arterial venting after near-drowning.

    Science.gov (United States)

    Kimura, Mitsutoshi; Kinoshita, Osamu; Fujimoto, Yoshifumi; Murakami, Arata; Shindo, Takahiro; Kashiwa, Koichi; Ono, Minoru

    2014-02-01

    Extracorporeal membrane oxygenation (ECMO) is an effective respiratory and circulatory support in patients in refractory cardiogenic shock or cardiac arrest. Peripheral ECMO sometimes requires left heart drainage; however, few reports state that pulmonary arterial (PA) venting is required during ECMO support. We present a case of a 14-year-old boy who required PA venting during ECMO support after resuscitation from near-drowning in freshwater. A biventricular assist device with an oxygenator implantation was intended on day 1; however, we were unable to proceed because of increasing of pulmonary vascular resistance from the acute lung injury. Central ECMO with PA venting was then performed. On day 13, central ECMO was converted to biventricular assist device with an oxygenator, which was removed on day 16. This case suggests that PA venting during ECMO support may be necessary in some cases of respiratory and circulatory failure with high pulmonary vascular resistance after near-drowning.

  15. Numerical analysis of the effects of a high gradient magnetic field on flowing erythrocytes in a membrane oxygenator

    International Nuclear Information System (INIS)

    Mitamura, Yoshinori; Okamoto, Eiji

    2015-01-01

    This study was carried out to clarify the effect of a high gradient magnetic field on pressure characteristics of blood in a hollow fiber membrane oxygenator in a solenoid coil by means of numerical analysis. Deoxygenated erythrocytes are paramagnetic, and oxygenated erythrocytes are diamagnetic. Blood changes its magnetic susceptibility depending on whether it is carrying oxygen or not. Motion of blood was analyzed by solving the continuous equation and the Navier–Stokes equation. It was confirmed that oxygenation of deoxygenated blood in the downstream side of the applied magnetic field was effective for pressure rise in a non-uniform magnetic field. The pressure rise was enhanced greatly by an increase in magnetic field intensity. The results suggest that a membrane oxygenator works as an actuator and there is a possibility of self-circulation of blood through an oxygenator in a non-uniform magnetic field. - Highlights: • Effects of a gradient magnetic field on erythrocytes in an oxygenator were analyzed. • Blood changes magnetic susceptibility depending on if it is carrying oxygen or not. • Oxygenation of deoxygenated blood is effective for pressure rise in a magnetic field. • A membrane oxygenator works as an actuator. • There is a possibility of self-circulation of blood through an oxygenator

  16. Numerical analysis of the effects of a high gradient magnetic field on flowing erythrocytes in a membrane oxygenator

    Energy Technology Data Exchange (ETDEWEB)

    Mitamura, Yoshinori, E-mail: ymitamura@par.odn.ne.jp; Okamoto, Eiji, E-mail: okamoto@tspirit.tokai-u.jp

    2015-04-15

    This study was carried out to clarify the effect of a high gradient magnetic field on pressure characteristics of blood in a hollow fiber membrane oxygenator in a solenoid coil by means of numerical analysis. Deoxygenated erythrocytes are paramagnetic, and oxygenated erythrocytes are diamagnetic. Blood changes its magnetic susceptibility depending on whether it is carrying oxygen or not. Motion of blood was analyzed by solving the continuous equation and the Navier–Stokes equation. It was confirmed that oxygenation of deoxygenated blood in the downstream side of the applied magnetic field was effective for pressure rise in a non-uniform magnetic field. The pressure rise was enhanced greatly by an increase in magnetic field intensity. The results suggest that a membrane oxygenator works as an actuator and there is a possibility of self-circulation of blood through an oxygenator in a non-uniform magnetic field. - Highlights: • Effects of a gradient magnetic field on erythrocytes in an oxygenator were analyzed. • Blood changes magnetic susceptibility depending on if it is carrying oxygen or not. • Oxygenation of deoxygenated blood is effective for pressure rise in a magnetic field. • A membrane oxygenator works as an actuator. • There is a possibility of self-circulation of blood through an oxygenator.

  17. Freestanding eggshell membrane-based electrodes for high-performance supercapacitors and oxygen evolution reaction.

    Science.gov (United States)

    Geng, Jing; Wu, Hao; Al-Enizi, Abdullah M; Elzatahry, Ahmed A; Zheng, Gengfeng

    2015-09-14

    A type of freestanding, light-weight eggshell membrane-based electrode is demonstrated for supercapacitors and for oxygen evolution reaction (OER) catalysis. As a widely available daily waste, eggshell membranes have unique porous three-dimensional grid-like fibrous structures with relatively high surface area and abundant macropores, allowing for effective conjugation of carbon nanotubes and growth of NiCo2O4 nanowire arrays, an effective supercapacitor material and OER catalyst. The three-dimensional fibrous eggshell membrane frameworks with carbon nanotubes offer efficient pathways for charge transport, and the macropores between adjacent fibers are fully accessible for electrolytes and bubble evolution. As a supercapacitor, the eggshell membrane/carbon nanotube/NiCo2O4 electrode shows high specific capacitances at current densities from 1 to 20 A g(-1), with excellent capacitance retention (>90%) at 10 A g(-1) for over 10,000 cycles. When employed as an OER catalyst, this eggshell membrane-based electrode exhibits an OER onset potential of 1.53 V vs. the reversible hydrogen electrode (RHE), and a stable catalytic current density of 20 mA cm(-2) at 1.65 V vs. the RHE.

  18. Mechanical ventilation management during extracorporeal membrane oxygenation for acute respiratory distress syndrome: a retrospective international multicenter study.

    Science.gov (United States)

    Schmidt, Matthieu; Stewart, Claire; Bailey, Michael; Nieszkowska, Ania; Kelly, Joshua; Murphy, Lorna; Pilcher, David; Cooper, D James; Scheinkestel, Carlos; Pellegrino, Vincent; Forrest, Paul; Combes, Alain; Hodgson, Carol

    2015-03-01

    To describe mechanical ventilation settings in adult patients treated for an acute respiratory distress syndrome with extracorporeal membrane oxygenation and assess the potential impact of mechanical ventilation settings on ICU mortality. Retrospective observational study. Three international high-volume extracorporeal membrane oxygenation centers. A total of 168 patients treated with extracorporeal membrane oxygenation for severe acute respiratory distress syndrome from January 2007 to January 2013. We analyzed the association between mechanical ventilation settings (i.e. plateau pressure, tidal volume, and positive end-expiratory pressure) on ICU mortality using multivariable logistic regression model and Cox-proportional hazards model. We obtained detailed demographic, clinical, daily mechanical ventilation settings and ICU outcome data. One hundred sixty-eight patients (41 ± 14 years old; PaO2/FIO2 67 ± 19 mm Hg) fulfilled our inclusion criteria. Median duration of extracorporeal membrane oxygenation and ICU stay were 10 days (6-18 d) and 28 days (16-42 d), respectively. Lower positive end-expiratory pressure levels and significantly lower plateau pressures during extracorporeal membrane oxygenation were used in the French center than in both Australian centers (23.9 ± 1.4 vs 27.6 ± 3.7 and 27.8 ± 3.6; p Protective mechanical ventilation strategies were routinely used in high-volume extracorporeal membrane oxygenation centers. However, higher positive end-expiratory pressure levels during the first 3 days on extracorporeal membrane oxygenation support were independently associated with improved survival. Further prospective trials on the optimal mechanical ventilation strategy during extracorporeal membrane oxygenation support are warranted.

  19. Oxygen diffusion-concentration in phospholipidic model membranes. An ESR-saturation study

    International Nuclear Information System (INIS)

    Vachon, A.; Lecomte, C.; Berleur, F.

    1986-04-01

    Fully hydrated liposomes of dipalmitoyl-phosphatidylcholine were labelled with 5 (or 7, 10, 12, 16)-doxyl stearic acid at pH 6 and 8, and studied by the continuous wave ESR-saturation technique. The ESR spectral magnitude depends on the hyperfrequency power P and on both T 1 and T 2 relaxation times. Saturation, i.e. the non linearity of the spectral magnitude plotted versus √P can be quantified by a P1/2 parameter (power at which the signal is half as great as it would be without saturation). If we assume T 2 weakly modified by spin exchange between paramagnetic spin probe and oxygen in triplet state, P1/2 is inversely proportional to T 1 , and becomes a sensitive parameter to appreciate the oxygen transport (oxygen diffusion-concentration product) inside the bilayers. According to the DPPC bilayer phase transition diagrams, P1/2 (oxygen diffusion-concentration) is related to the thermodynamic state of the membrane. This technique provides further informations on a particular property of a radioprotective agent, cysteamine, which seems to inhibit spin-triplet exchange and hence maximizes T 1 (minimizes P1/2). Since radioprotective agents are known to act by scavenging radiation-induced free radicals and by inhibiting oxygen-dependent free radical processes, such a result may contribute to elucidate radioprotecting mechanisms

  20. Palmitoylated claudin7 captured in glycolipid-enriched membrane microdomains promotes metastasis via associated transmembrane and cytosolic molecules

    OpenAIRE

    Thuma, Florian; Heiler, Sarah; Schn?lzer, Martina; Z?ller, Margot

    2016-01-01

    In epithelial cells claudin7 (cld7) is a major component of tight junctions, but is also recovered from glycolipid-enriched membrane microdomains (GEM). In tumor cells, too, cld7 exists in two stages. Only GEM-located cld7, which is palmitoylated, promotes metastasis. Searching for the underlying mechanism(s) revealed the following. The metastatic capacity of the rat pancreatic adenocarcinoma cell line ASML is lost by a knockdown (kd) of cld7 and is not regained by rescuing cld7 with a mutate...

  1. Graphene oxide enrichment of collagen membranes improves DPSCs differentiation and controls inflammation occurrence.

    Science.gov (United States)

    Radunovic, Milena; De Colli, Marianna; De Marco, Patrizia; Di Nisio, Chiara; Fontana, Antonella; Piattelli, Adriano; Cataldi, Amelia; Zara, Susi

    2017-08-01

    Collagen membranes are used in oral surgery for bone defects treatment acting as a barrier that does not allow the invasion of soft tissue into the growing bone. To improve biocompatibility collagen membranes were coated with graphene oxide (GO), a graphene derivative. The aim of this study was to investigate the biocompatibility of GO coated collagen membranes on human dental pulp stem cells (DPSCs) focusing on biomaterial cytotoxicity, ability to promote DPSCs differentiation process and to control inflammation event induction. DPSCs were cultured on uncoated membranes and on both 2 and 10 μg mL -1 GO coated membranes up to 28 days. Alamar blue and LDH cytotocicity assay, PGE2 ELISA assay, real time RT-PCR for RUNX2, BMP2, SP7, TNFα and COX2 genes expression were performed. Proliferation is higher on GO coated membranes at days 14 and 28. LDH assay evidences no cytotoxicity. BMP2 and RUNX2 expression is higher on coated membranes, BMP2 at early and RUNX2 and SP7 at late experimental times. PGE2 levels are lower on GO coated membranes at days 14 and 28, both TNFα and COX2 expression is significantly decreased when GO is applied. GO coated membranes are not toxic for DPSCs, induce a faster DPSCs differentiation into odontoblasts/osteoblasts and may represent good alternative to conventional membranes thus ensuring more efficient bone formation and improving the clinical performance. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2312-2320, 2017. © 2017 Wiley Periodicals, Inc.

  2. Application of Electron Structure Calculations to the Migration of Oxygen through a Perovskite Membrane

    Science.gov (United States)

    Wood, Douglas A.

    The focus of this thesis is the application of electron structure calculations, particularly density functional theory, to the analysis of the process by which oxygen is able to migrate through a perovskite crystal. This property creates the possibility of using perovskite membranes to separate oxygen from air. This could be applied to the generation of syngas directly from natural gas without the need for a separate air separation unit. A perovskite has the nominal formula ABO3 where A is a rare earth type cation and B is a transition type cation. The structure consists of the B cations arranged in a cube with the A cation in the center. The oxygen ions are located at the midpoint of each B-B cube edge and form an octahedron centered on each B cation. Any real perovskite crystal will contain a certain fraction of vacancies at the oxygen sites. Oxygen migrates through the crystal by jumping from a neighboring site to the vacancy. The permeability of the crystal is thus a function of the concentration of vacancies and the activation energy of the jump from a neighboring site to the vacancy. These properties can be modified by adding dopants for the A and B cations. The literature contains a substantial amount of experimental work on the effect of such dopants. The overall migration process can be divided into components (i) the concentration of oxygen vacancies, (ii) the activation energy for a neighboring on-site oxygen atom to jump to the vacant site, (iii) the concentration of surface vacancies, and (iv) the processes by which oxygen ions transfer back and forth between the perovskite surface and the contiguous vapor space. Using SrTiO3 and LaCoO3 as model compounds, DFT calculations have been used to (i) calculate various properties of the perovskite crystal, (ii) estimate the activation energy of a jump between an occupied oxygen site and an adjacent vacant oxygen site, (iii) predict the effects of various dopants at the A and B site and (iv) analyze the

  3. Topology and immersion depth of an integral membrane protein by paramagnetic rates from dissolved oxygen.

    Science.gov (United States)

    Al-Abdul-Wahid, M Sameer; Verardi, Raffaello; Veglia, Gianluigi; Prosser, R Scott

    2011-09-01

    In studies of membrane proteins, knowledge of protein topology can provide useful insight into both structure and function. In this work, we present a solution NMR method for the measurement the tilt angle and average immersion depth of alpha helices in membrane proteins, from analysis of the paramagnetic relaxation rate enhancements arising from dissolved oxygen. No modification to the micelle or protein is necessary, and the topology of both transmembrane and amphipathic helices are readily determined. We apply this method to the measure the topology of a monomeric mutant of phospholamban (AFA-PLN), a 52-residue membrane protein containing both an amphipathic and a transmembrane alpha helix. In dodecylphosphocholine micelles, the amphipathic helix of AFA-PLN was found to have a tilt angle of 87° ± 1° and an average immersion depth of 13.2 Å. The transmembrane helix was found to have an average immersion depth of 5.4 Å, indicating residues 41 and 42 are closest to the micelle centre. The resolution of paramagnetic relaxation rate enhancements from dissolved oxygen compares favourably to those from Ni (II), a hydrophilic paramagnetic species.

  4. Topology and immersion depth of an integral membrane protein by paramagnetic rates from dissolved oxygen

    International Nuclear Information System (INIS)

    Al-Abdul-Wahid, M. Sameer; Verardi, Raffaello; Veglia, Gianluigi; Prosser, R. Scott

    2011-01-01

    In studies of membrane proteins, knowledge of protein topology can provide useful insight into both structure and function. In this work, we present a solution NMR method for the measurement the tilt angle and average immersion depth of alpha helices in membrane proteins, from analysis of the paramagnetic relaxation rate enhancements arising from dissolved oxygen. No modification to the micelle or protein is necessary, and the topology of both transmembrane and amphipathic helices are readily determined. We apply this method to the measure the topology of a monomeric mutant of phospholamban (AFA-PLN), a 52-residue membrane protein containing both an amphipathic and a transmembrane alpha helix. In dodecylphosphocholine micelles, the amphipathic helix of AFA-PLN was found to have a tilt angle of 87° ± 1° and an average immersion depth of 13.2 Å. The transmembrane helix was found to have an average immersion depth of 5.4 Å, indicating residues 41 and 42 are closest to the micelle centre. The resolution of paramagnetic relaxation rate enhancements from dissolved oxygen compares favourably to those from Ni (II), a hydrophilic paramagnetic species.

  5. Amorphous metallic alloys for oxygen reduction reaction in a polymer electrolyte membrane fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Huerta, R.; Guerra-Martinez, I.; Lopez, J.S. [Inst. Politecnico Nacional, ESIQIE, Mexico City (Mexico). Lab. de Electroquimica; Pierna, A.R. [Basque Country Univ., San Sebastian (Spain). Dept. of Chemical Engineering and Environment; Solorza-Feria, O. [Inst. Politenico Nacional, Centro de Investigacion y de Estudios Avanzados, Mexico City (Mexico). Dept. de Quimica

    2010-07-15

    Direct methanol fuel cells (DMFC) and polymer electrolyte membrane fuel cells (PEMFC) represent an important, environmentally clean energy source. This has motivated extensive research on the synthesis, characterization and evaluation of novel and stable oxygen reduction electrocatalysts for the direct four-electron transfer process to water formation. Studies have shown that amorphous alloyed compounds can be used as electrode materials in electrochemical energy conversion devices. Their use in PEMFCs can optimize the electrocatalyst loading in the membrane electrode assembly (MEA). In this study, amorphous metallic PtSn, PtRu and PtRuSn alloys were synthesized by mechanical milling and used as cathodes for the oxygen reduction reaction (ORR) in sulphuric acid and in a single PEM fuel cell. Two different powder morphologies were observed before and after the chemical activation in a hydrofluoric acid (HF) solution at 25 degrees C. The kinetics of the ORR on the amorphous catalysts were investigated. The study showed that the amorphous metallic PtSn electrocatalyst was the most active of the 3 electrodes for the cathodic reaction. Fuel cell experiments were conducted at various temperatures at 30 psi for hydrogen (H{sub 2}) and at 34 psi for oxygen (O{sub 2}). MEAs made of Nafion 115 and amorphous metallic PtSn dispersed on carbon powder in a PEMFC had a power density of 156 mW per cm{sup 2} at 0.43V and 80 degrees C. 12 refs., 1 tab., 5 figs.

  6. Artificial membrane-binding proteins stimulate oxygenation of stem cells during engineering of large cartilage tissue

    Science.gov (United States)

    Armstrong, James P. K.; Shakur, Rameen; Horne, Joseph P.; Dickinson, Sally C.; Armstrong, Craig T.; Lau, Katherine; Kadiwala, Juned; Lowe, Robert; Seddon, Annela; Mann, Stephen; Anderson, J. L. Ross; Perriman, Adam W.; Hollander, Anthony P.

    2015-06-01

    Restricted oxygen diffusion can result in central cell necrosis in engineered tissue, a problem that is exacerbated when engineering large tissue constructs for clinical application. Here we show that pre-treating human mesenchymal stem cells (hMSCs) with synthetic membrane-active myoglobin-polymer-surfactant complexes can provide a reservoir of oxygen capable of alleviating necrosis at the centre of hyaline cartilage. This is achieved through the development of a new cell functionalization methodology based on polymer-surfactant conjugation, which allows the delivery of functional proteins to the hMSC membrane. This new approach circumvents the need for cell surface engineering using protein chimerization or genetic transfection, and we demonstrate that the surface-modified hMSCs retain their ability to proliferate and to undergo multilineage differentiation. The functionalization technology is facile, versatile and non-disruptive, and in addition to tissue oxygenation, it should have far-reaching application in a host of tissue engineering and cell-based therapies.

  7. A novel approach to the management of critically ill neonatal Ebstein's anomaly: Veno-venous extracorporeal membrane oxygenation to promote right ventricular recovery.

    Science.gov (United States)

    Bauser-Heaton, Holly; Nguyen, Charles; Tacy, Theresa; Axelrod, David

    2015-01-01

    This is the first report of the use of veno-venous extracorporeal membrane oxygenation in a neonate with severe Ebstein's anomaly. The report suggests the use of veno-venous extracorporeal membrane oxygenation in the immediate neonatal period may be a useful therapy in severe Ebstein's anomaly. By providing adequate oxygenation independent of the patient's native pulmonary blood flow, veno-venous extracorporeal membrane oxygenation allows the pulmonary vascular resistance to decrease and may promote right ventricular recovery.

  8. Research and Development on Oxygen Transport Membranes at the Technical University of Denmark from Materials to Modules

    DEFF Research Database (Denmark)

    Kiebach, Wolff-Ragnar; Pirou, Stéven; Ovtar, Simona

    2016-01-01

    Oxygen transport membranes (OTMs) are inorganic, high temperature devices that have the potential to efficiently supply oxygen to combustion processes, for example for oxy-fired (biomass) gasification or in the cement and steel industry. This work reviews aspects of material selection, design...

  9. Productivity variations, oxygen minimum zone and their impact on organic enrichment in the sediments

    Digital Repository Service at National Institute of Oceanography (India)

    Paropkari, A.L.

    of Somalia, the Arabian Peninsula, Iran, Pakistan and Eastern and Western shelves of India (except a part of inner shelf), irrespective of primary productivity variation (Fig. 3), is mainly ascribed to decomposition of organic matter in contact.... Nevertheless, moderate to very high concentrations of organic carbon (Fig. 1) are invariably associated with the entire slope sediments, forming a long and wide band in contact with oxygen minima from Saurashtra to the southern tip of India. It may...

  10. Factors associated with blood oxygen partial pressure and carbon dioxide partial pressure regulation during respiratory extracorporeal membrane oxygenation support: data from a swine model.

    Science.gov (United States)

    Park, Marcelo; Mendes, Pedro Vitale; Costa, Eduardo Leite Vieira; Barbosa, Edzangela Vasconcelos Santos; Hirota, Adriana Sayuri; Azevedo, Luciano Cesar Pontes

    2016-01-01

    The aim of this study was to explore the factors associated with blood oxygen partial pressure and carbon dioxide partial pressure. The factors associated with oxygen - and carbon dioxide regulation were investigated in an apneic pig model under veno-venous extracorporeal membrane oxygenation support. A predefined sequence of blood and sweep flows was tested. Oxygenation was mainly associated with extracorporeal membrane oxygenation blood flow (beta coefficient = 0.036mmHg/mL/min), cardiac output (beta coefficient = -11.970mmHg/L/min) and pulmonary shunting (beta coefficient = -0.232mmHg/%). Furthermore, the initial oxygen partial pressure and carbon dioxide partial pressure measurements were also associated with oxygenation, with beta coefficients of 0.160 and 0.442mmHg/mmHg, respectively. Carbon dioxide partial pressure was associated with cardiac output (beta coefficient = 3.578mmHg/L/min), sweep gas flow (beta coefficient = -2.635mmHg/L/min), temperature (beta coefficient = 4.514mmHg/ºC), initial pH (beta coefficient = -66.065mmHg/0.01 unit) and hemoglobin (beta coefficient = 6.635mmHg/g/dL). In conclusion, elevations in blood and sweep gas flows in an apneic veno-venous extracorporeal membrane oxygenation model resulted in an increase in oxygen partial pressure and a reduction in carbon dioxide partial pressure 2, respectively. Furthermore, without the possibility of causal inference, oxygen partial pressure was negatively associated with pulmonary shunting and cardiac output, and carbon dioxide partial pressure was positively associated with cardiac output, core temperature and initial hemoglobin.

  11. Oxygen Selective Membranes for Li-Air (O2 Batteries

    Directory of Open Access Journals (Sweden)

    Mark Salomon

    2012-05-01

    Full Text Available Lithium-air (Li-air batteries have a much higher theoretical energy density than conventional lithium batteries and other metal air batteries, so they are being developed for applications that require long life. Water vapor from air must be prevented from corroding the lithium (Li metal negative electrode during discharge under ambient conditions, i.e., in humid air. One method of protecting the Li metal from corrosion is to use an oxygen selective membrane (OSM that allows oxygen into the cell while stopping or slowing the ingress of water vapor. The desired properties and some potential materials for OSMs for Li-air batteries are discussed and the literature is reviewed.

  12. Three-dimensional MR angiography of the intracranial circulation in neonates following extracorporeal membrane oxygenation

    International Nuclear Information System (INIS)

    Lewin, J.S.; Masaryk, T.J.; Wiznitzer, M.; Ross, J.S.; Modic, M.T.; Stork, E.K.; Bryan, P.J.; Butler, H.

    1988-01-01

    Extracorporeal membrane oxygenation (ECMO) is a neonatal systemic oxygenation technique that involves cannulation and subsequent ligation of the right internal jugular vein and common carotid artery. The purpose of this study was to implement a comprehensive neurovascular evaluation in these patients by means of a new three-dimensional MR angiography technique that used reduced echo time and voxel size, gradient refocusing, and time-of-flight effects to maximize vascular contrast. A standard T2-weighted multiecho MR imaging study was also performed. The patient population consisted of 12 infants who had undergone ECMO. Vascular examinations of diagnostic quality were performed in 80% of patients. The findings indicate that MR angiography is a reliable method for evaluation of the intracranial circulation in patients following ECMO therapy

  13. [Traumatic tricuspid valve insufficiency with right-to-left shunt: bridging using extracorporeal venovenous membrane oxygenation].

    Science.gov (United States)

    Weber, S U; Hammerstingl, C; Mellert, F; Baumgarten, G; Putensen, C; Knuefermann, P

    2012-01-01

    The case of a young male motor vehicle driver is reported who suffered multiple trauma in a car accident with pulmonary and cardiac contusions. In the course of severe pneumonia and traumatic tricuspid valve insufficiency a right-to-left shunt with refractory hypoxemia developed across a pre-existing atrial septal defect (ASD). The patient could be successfully treated by the combination of extracorporeal membrane oxygenation for bridging, interventional ASD occlusion and in the long-term by operative reconstruction of the tricuspid valve.

  14. Design and optimization of porous ceramic supports for asymmetric ceria-based oxygen transport membranes

    DEFF Research Database (Denmark)

    Kaiser, Andreas; Foghmoes, Søren Preben Vagn; Pećanac, G.

    2016-01-01

    The microstructure, mechanical properties and gas permeability of porous supports of Ce0.9Gd0.1O1.95−δ (CGO) were investigated as a function of sintering temperature and volume fraction of pore former for use in planar asymmetric oxygen transport membranes (OTMs). With increasing the pore former...... content from 11 vol% to 16 vol%, the gas permeabilities increased by a factor of 5 when support tapes were sintered to comparable densities. The improved permeabilities were due to a more favourable microstructure with larger interconnected pores at a porosity of 45% and a fracture strength of 47±2 MPa (m...

  15. Enrichment of Thermophilic Syntrophic Anaerobic Glutamate-Degrading Consortia using a Dialysis Membrane Reactor

    NARCIS (Netherlands)

    Plugge, C.M.; Stams, A.J.M.

    2002-01-01

    A dialysis cultivation system was used to enrich slow-growing moderately thermophilic anaerobic bacteria at high cell densities. Bicarbonate buffered mineral salts medium with 5 mM glutamate as the sole carbon and energy source was used and the incubation temperature was 55 degrees C. The reactor

  16. A novel zincum-doped perovskite-type ceramic membrane for oxygen separation

    Energy Technology Data Exchange (ETDEWEB)

    Chen Xinzhi; Liu Hongfei; Wei Yanying [School of Chemistry and Chemical Engineering, South China University of Technology, No. 381 Wushan Road, 510640 Guangzhou (China); Caro Juergen [Institute of Physical Chemistry and Electrochemistry, Leibniz University Hannover, Callinstr. 3-3A D-30179 Hannover (Germany); Wang Haihui, E-mail: hhwang@scut.edu.c [School of Chemistry and Chemical Engineering, South China University of Technology, No. 381 Wushan Road, 510640 Guangzhou (China)

    2009-09-18

    Zincum-doped ceramic membrane materials based on BaCo{sub 0.4}Fe{sub 0.4}Zn{sub x}Zr{sub (0.2-x)}O{sub 3-delta} with 0 <= x <= 0.2 were synthesized by combining citric acid and ethylene-diamine-tetraacetic acid (EDTA) complexing method. X-ray diffraction (XRD) patterns show that the BaCo{sub 0.4}Fe{sub 0.4}Zn{sub 0.2}O{sub 3-delta} ceramic oxide exhibits a pure cubic perovskite structure. Oxygen temperature-programmed desorption (O{sub 2}-TPD) profile indicates that BaCo{sub 0.4}Fe{sub 0.4}Zn{sub 0.2}O{sub 3-delta} possesses a good phase reversibility. An oxygen permeation flux of 0.65 ml/min cm{sup 2} was obtained at 950 deg. C and a single activation energy of 67 kJ/mol was observed for the oxygen permeation in the temperature range of 600-950 deg. C. No decline was found during more than 100 h oxygen permeation.

  17. Simultaneous enrichment of denitrifying anaerobic methane-oxidizing microorganisms and anammox bacteria in a hollow-fiber membrane biofilm reactor.

    Science.gov (United States)

    Ding, Zhao-Wei; Lu, Yong-Ze; Fu, Liang; Ding, Jing; Zeng, Raymond J

    2017-01-01

    In this study, the coculture system of denitrifying anaerobic methane oxidation (DAMO) microbes and anaerobic ammonium oxidation (anammox) bacteria was successfully enriched in a hollow-fiber membrane biofilm reactor (HfMBR) using freshwater sediment as the inoculum. The maximal removal rates of nitrate and ammonium were 78 mg N/L/day (131 mg N/m 2 /day) and 26 mg N/L/day (43 mg N/m 2 /day), respectively. Due to the high rate of methane mass transfer in HfMBR, the activity of DAMO archaea continued to increase during the enrichment period, indicating that HfMBR could be a powerful tool to enrich DAMO microorganisms. Effects of partial methane pressure, temperature, and pH on the cocultures were obvious. However, the microbial activity in HfMBR could be recovered quickly after the shock change of environmental factors. Furthermore, the result also found that DAMO bacteria likely had a stronger competitive advantage than anammox bacteria under the operating conditions in this study. High-throughput sequencing 16S rRNA genes illustrated that the dominant microbes were NC10, Euryarchaeota, Proteobacteria, Planctomycetes, and Chlorobi with relative abundance of 38.8, 26.2, 13.78, 6.2, and 3.6 %, respectively.

  18. High sensitivity of Lobelia dortmanna to sediment oxygen depletion following organic enrichment

    DEFF Research Database (Denmark)

    Møller, Claus Lindskov; Jensen, Kaj Sand

    2011-01-01

    • Lobelia dortmanna thrives in oligotrophic, softwater lakes thanks to O(2) and CO(2) exchange across roots and uptake of sediment nutrients. We hypothesize that low gas permeability of leaves constrains Lobelia to pristine habitats because plants go anoxic in the dark if O(2) vanishes from...... sediments. • We added organic matter to sediments and followed O(2) dynamics in plants and sediments using microelectrodes. To investigate plant stress, nutrient content and photosynthetic capacity of leaves were measured. • Small additions of organic matter triggered O(2) depletion and accumulation of NH(4......)(+), Fe(2+) and CO(2) in sediments. O(2) in leaf lacunae fluctuated from above air saturation in the light to anoxia late in the dark in natural sediments, but organic enrichment prolonged anoxia because of higher O(2) consumption and restricted uptake from the water. Leaf N and P dropped below minimum...

  19. Dually Fluorescent Sensing of pH and Dissolved Oxygen Using a Membrane Made from Polymerizable Sensing Monomers.

    Science.gov (United States)

    Tian, Yanqing; Shumway, Bradley R; Youngbull, A Cody; Li, Yongzhong; Jen, Alex K-Y; Johnson, Roger H; Meldrum, Deirdre R

    2010-06-03

    Using a thermal polymerization approach and polymerizable pH and oxygen sensing monomers with green and red emission spectra, respectively, new pH, oxygen, and their dual sensing membranes were prepared using poly(2-hydroxyethyl methacrylate)-co-poly(acrylamide) as a matrix. The sensors were grafted on acrylate-modified quartz glass and characterized under different pH values, oxygen concentrations, ion strengths, temperatures and cell culture media. The pH and oxygen sensors were excited using the same excitation wavelength and exhibited well-separated emission spectra. The pH-sensing films showed good response over the pH range 5.5 to 8.5, corresponding to pK(a) values in the biologically-relevant range between 6.9 and 7.1. The oxygen-sensing films exhibited linear Stern-Volmer quenching responses to dissolved oxygen. As the sensing membranes were prepared using thermally initiated polymerization of sensing moiety-containing monomers, no leaching of the sensors from the membranes to buffers or medium was observed. This advantageous characteristic accounts in part for the sensors' biocompatibility without apparent toxicity to HeLa cells after 40 hours incubation. The dual-sensing membrane was used to measure pH and dissolved oxygen simultaneously. The measured results correlated with the set-point values.

  20. Highly Efficient Single-Step Enrichment of Low Abundance Phosphopeptides from Plant Membrane Preparations

    Directory of Open Access Journals (Sweden)

    Xu Na Wu

    2017-09-01

    Full Text Available Mass spectrometry (MS-based large scale phosphoproteomics has facilitated the investigation of plant phosphorylation dynamics on a system-wide scale. However, generating large scale data sets for membrane phosphoproteins usually requires fractionation of samples and extended hands-on laboratory time. To overcome these limitations, we developed “ShortPhos,” an efficient and simple phosphoproteomics protocol optimized for research on plant membrane proteins. The optimized workflow allows fast and efficient identification and quantification of phosphopeptides, even from small amounts of starting plant materials. “ShortPhos” can produce label-free datasets with a high quantitative reproducibility. In addition, the “ShortPhos” protocol recovered more phosphorylation sites from membrane proteins, especially plasma membrane and vacuolar proteins, when compared to our previous workflow and other membrane-based data in the PhosPhAt 4.0 database. We applied “ShortPhos” to study kinase-substrate relationships within a nitrate-induction experiment on Arabidopsis roots. The “ShortPhos” identified significantly more known kinase-substrate relationships compared to previous phosphoproteomics workflows, producing new insights into nitrate-induced signaling pathways.

  1. The assembly of GM1 glycolipid- and cholesterol-enriched raft-like membrane microdomains is important for giardial encystation.

    Science.gov (United States)

    De Chatterjee, Atasi; Mendez, Tavis L; Roychowdhury, Sukla; Das, Siddhartha

    2015-05-01

    Although encystation (or cyst formation) is an important step of the life cycle of Giardia, the cellular events that trigger encystation are poorly understood. Because membrane microdomains are involved in inducing growth and differentiation in many eukaryotes, we wondered if these raft-like domains are assembled by this parasite and participate in the encystation process. Since the GM1 ganglioside is a major constituent of mammalian lipid rafts (LRs) and known to react with cholera toxin B (CTXB), we used Alexa Fluor-conjugated CTXB and GM1 antibodies to detect giardial LRs. Raft-like structures in trophozoites are located in the plasma membranes and on the periphery of ventral discs. In cysts, however, they are localized in the membranes beneath the cyst wall. Nystatin and filipin III, two cholesterol-binding agents, and oseltamivir (Tamiflu), a viral neuraminidase inhibitor, disassembled the microdomains, as evidenced by reduced staining of trophozoites with CTXB and GM1 antibodies. GM1- and cholesterol-enriched LRs were isolated from Giardia by density gradient centrifugation and found to be sensitive to nystatin and oseltamivir. The involvement of LRs in encystation could be supported by the observation that raft inhibitors interrupted the biogenesis of encystation-specific vesicles and cyst production. Furthermore, culturing of trophozoites in dialyzed medium containing fetal bovine serum (which is low in cholesterol) reduced raft assembly and encystation, which could be rescued by adding cholesterol from the outside. Our results suggest that Giardia is able to form GM1- and cholesterol-enriched lipid rafts and these raft domains are important for encystation. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  2. Apparent Km of mitochondria for oxygen computed from Vmax measured in permeabilized muscle fibers is lower in water enriched in oxygen by electrolysis than injection

    Directory of Open Access Journals (Sweden)

    Zoll J

    2015-07-01

    Full Text Available Joffrey Zoll,1 Jamal Bouitbir,1 Pascal Sirvent,2 Alexis Klein,3 Antoine Charton,1,4 Liliana Jimenez,3 François R Péronnet,5 Bernard Geny,1 Ruddy Richard61Physiology Department, Faculty of Medicine and EA3072, Université de Strasbourg, Strasbourg, 2Clermont Université, Université Blaise Pascal, EA 3533, Laboratoire des Adaptations Métaboliques à l’Exercice en Conditions Physiologiques et Pathologiques, Clermont-Ferrand, 3Danone Research, Centre Daniel Carasso, Palaiseau, 4Department of Anesthesia and Critical Care and EA3072, Hôpital de Hautepierre, Université de Strasbourg, France; 5Kinesiology Department, Université de Montréal, Montréal, QC, Canada; 6Department of Sport Medicine and Functional Explorations and INRA UMR 1019, Faculty of Medicine, Université d’Auvergne, Clermont-Ferrand, FranceBackground: It has been suggested that oxygen (O2 diffusion could be favored in water enriched in O2 by a new electrolytic process because of O2 trapping in water superstructures (clathrates, which could reduce the local pressure/content relationships for O2 and facilitate O2 diffusion along PO2 gradients.Materials and methods: Mitochondrial respiration was compared in situ in saponin-skinned fibers isolated from the soleus muscles of Wistar rats, in solution enriched in O2 by injection or the electrolytic process 1 at an O2 concentration decreasing from 240 µmol/L to 10 µmol/L (132 mmHg to 5 mmHg, with glutamate–malate or N, N, N', N'-tetramethyl-p-phenylenediamine dihydrochloride (TMPD–ascorbate (with antimycin A as substrates; and 2 at increasing adenosine diphosphate (ADP concentration with glutamate–malate as substrate.Results: As expected, maximal respiration decreased with O2 concentration and, when compared to glutamate–malate, the apparent Km O2 of mitochondria for O2 was significantly lower with TMPD–ascorbate with both waters. However, when compared to the water enriched in O2 by injection, the Km O2 was

  3. Oxygen transport membrane reactor based method and system for generating electric power

    Science.gov (United States)

    Kelly, Sean M.; Chakravarti, Shrikar; Li, Juan

    2017-02-07

    A carbon capture enabled system and method for generating electric power and/or fuel from methane containing sources using oxygen transport membranes by first converting the methane containing feed gas into a high pressure synthesis gas. Then, in one configuration the synthesis gas is combusted in oxy-combustion mode in oxygen transport membranes based boiler reactor operating at a pressure at least twice that of ambient pressure and the heat generated heats steam in thermally coupled steam generation tubes within the boiler reactor; the steam is expanded in steam turbine to generate power; and the carbon dioxide rich effluent leaving the boiler reactor is processed to isolate carbon. In another configuration the synthesis gas is further treated in a gas conditioning system configured for carbon capture in a pre-combustion mode using water gas shift reactors and acid gas removal units to produce hydrogen or hydrogen-rich fuel gas that fuels an integrated gas turbine and steam turbine system to generate power. The disclosed method and system can also be adapted to integrate with coal gasification systems to produce power from both coal and methane containing sources with greater than 90% carbon isolation.

  4. Extracorporeal membrane oxygenation (ECMO as salvage treatment for pulmonary Echinococcus granulosus infection with acute cyst rupture

    Directory of Open Access Journals (Sweden)

    Sören L. Becker

    2017-11-01

    Full Text Available Extracorporeal membrane oxygenation (ECMO has been used successfully for the treatment of patients with respiratory failure due to severe infections. Although rare, parasites can also cause severe pulmonary disease. Tapeworms of the genus Echinococcus give rise to the development of cystic structures in the liver, lungs, and other organs. Acute cyst rupture leads to potentially life-threatening infection, and affected patients may deteriorate rapidly. The case of a young woman from Bulgaria who was admitted to hospital with severe dyspnoea, progressive chest pain, and haemoptysis is described. Computed tomography of the chest was pathognomonic for cystic echinococcosis with acute cyst rupture. Following deterioration on mechanical ventilation, she was cannulated for veno-venous ECMO. The patient’s condition improved considerably, and she was weaned successfully from ECMO and mechanical ventilation. Following lobectomy of the affected left lower lobe, the patient was discharged home in good condition. This appears to be the first report of the successful use of ECMO as salvage treatment for a severe manifestation of a helminthic disease. Due to recent migration to Western Europe, the number of patients presenting with respiratory failure due to pulmonary echinococcosis with cyst rupture is likely to increase. Keywords: Extracorporeal membrane oxygenation (ECMO, Infection, Echinococcosis, Echinococcus granulosus, Hydatid disease, Infection

  5. Membrane transporters mediating root signalling and adaptive responses to oxygen deprivation and soil flooding.

    Science.gov (United States)

    Shabala, Sergey; Shabala, Lana; Barcelo, Juan; Poschenrieder, Charlotte

    2014-10-01

    This review provides a comprehensive assessment of a previously unexplored topic: elucidating the role that plasma- and organelle-based membrane transporters play in plant-adaptive responses to flooding. We show that energy availability and metabolic shifts under hypoxia and anoxia are critical in regulating membrane-transport activity. We illustrate the high tissue and time dependence of this regulation, reveal the molecular identity of transporters involved and discuss the modes of their regulation. We show that both reduced oxygen availability and accumulation of transition metals in flooded roots result in a reduction in the cytosolic K(+) pool, ultimately determining the cell's fate and transition to programmed cell death (PCD). This process can be strongly affected by hypoxia-induced changes in the amino acid pool profile and, specifically, ϒ-amino butyric acid (GABA) accumulation. It is suggested that GABA plays an important regulatory role, allowing plants to proceed with H2 O2 signalling to activate a cascade of genes that mediate plant adaptation to flooding while at the same time, preventing the cell from entering a 'suicide program'. We conclude that progress in crop breeding for flooding tolerance can only be achieved by pyramiding the numerous physiological traits that confer efficient energy maintenance, cytosolic ion homeostasis, and reactive oxygen species (ROS) control and detoxification. © 2014 John Wiley & Sons Ltd.

  6. Creation of oxygen-enriched layers at the surface of GaAs single crystal

    International Nuclear Information System (INIS)

    Kulik, M.; Maczka, D.; Kobzev, A.P.

    1999-01-01

    The optical properties and the element depth profiles at the (100) plane high resistant and noncomposite GaAs single crystals implanted with In ions were investigated. The results have been compared with those obtained for virgin samples. The optic properties for all of the samples (implanted and not implanted, annealed and not annealed) have been measured using the ellipsometric method. The element depth profiles for the same samples have been obtained by the RBS and NRA techniques. It has been shown that the post-implantation annealing at a temperature more than 600 deg C leads to a ten time increase in contents of oxygen atoms in the implanted layer with respect to the not annealed sample. The thickness of the transparence layer at the surface of GaAs single crystal increases also after implantation with In ions and subsequent annealing

  7. Effect of Long Time Oxygen Exposure on Power Generation of Microbial Fuel Cell with Enriched Mixed Culture

    International Nuclear Information System (INIS)

    Mimi Hani Abu Bakar; Mimi Hani Abu Bakar; Mimi Hani Abu Bakar; Pasco, N.F.; Gooneratne, R.; Hong, K.B.; Hong, K.B.; Hong, K.B.

    2016-01-01

    In this study, we are interested in the effect of long time exposure of the microbial fuel cells (MFCs) to air on the electrochemical performance. Here, MFCs enriched using an effluent from a MFC operated for about eight months. After 30 days, the condition of these systems was reversed from aerobic to anaerobic and vice versa, and their effects were observed for 11 days. The results show that for anaerobic MFCs, power generation was reduced when the anodes were exposed to dissolved oxygen of 7.5 ppm. The long exposure of anodic biofilm to air led to poor electrochemical performance. The power generation recovered fully when air supply stopped entering the anode compartment with a reduction of internal resistance up to 53 %. The study was able to show that mixed facultative microorganism able to strive through the aerobic condition for about a month at 7.5 ppm oxygen or less. The anaerobic condition was able to turn these microbes into exoelectrogen, producing considerable power in relative to their aerobic state. (author)

  8. Seasonal transfer of oxygen isotopes from precipitation and soil to the tree ring: source water versus needle water enrichment.

    Science.gov (United States)

    Treydte, Kerstin; Boda, Sonja; Graf Pannatier, Elisabeth; Fonti, Patrick; Frank, David; Ullrich, Bastian; Saurer, Matthias; Siegwolf, Rolf; Battipaglia, Giovanna; Werner, Willy; Gessler, Arthur

    2014-05-01

    For accurate interpretation of oxygen isotopes in tree rings (δ(18) O), it is necessary to disentangle the mechanisms underlying the variations in the tree's internal water cycle and to understand the transfer of source versus leaf water δ(18) O to phloem sugars and stem wood. We studied the seasonal transfer of oxygen isotopes from precipitation and soil water through the xylem, needles and phloem to the tree rings of Larix decidua at two alpine sites in the Lötschental (Switzerland). Weekly resolved δ(18) O records of precipitation, soil water, xylem and needle water, phloem organic matter and tree rings were developed. Week-to-week variations in needle-water (18) O enrichment were strongly controlled by weather conditions during the growing season. These short-term variations were, however, not significantly fingerprinted in tree-ring δ(18) O. Instead, seasonal trends in tree-ring δ(18) O predominantly mirrored trends in the source water, including recent precipitation and soil water pools. Modelling results support these findings: seasonal tree-ring δ(18) O variations are captured best when the week-to-week variations of the leaf water signal are suppressed. Our results suggest that climate signals in tree-ring δ(18) O variations should be strongest at temperate sites with humid conditions and precipitation maxima during the growing season. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  9. Impact of Right Ventricular Performance in Patients Undergoing Extracorporeal Membrane Oxygenation Following Cardiac Surgery.

    Science.gov (United States)

    Bartko, Philipp E; Wiedemann, Dominik; Schrutka, Lore; Binder, Christina; Santos-Gallego, Carlos G; Zuckermann, Andreas; Steinlechner, Barbara; Koinig, Herbert; Heinz, Gottfried; Niessner, Alexander; Zimpfer, Daniel; Laufer, Günther; Lang, Irene M; Distelmaier, Klaus; Goliasch, Georg

    2017-07-28

    Extracorporeal membrane oxygenation following cardiac surgery safeguards end-organ oxygenation but unfavorably alters cardiac hemodynamics. Along with the detrimental effects of cardiac surgery to the right heart, this might impact outcome, particularly in patients with preexisting right ventricular (RV) dysfunction. We sought to determine the prognostic impact of RV function and to improve established risk-prediction models in this vulnerable patient cohort. Of 240 patients undergoing extracorporeal membrane oxygenation support following cardiac surgery, 111 had echocardiographic examinations at our institution before implantation of extracorporeal membrane oxygenation and were thus included. Median age was 67 years (interquartile range 60-74), and 74 patients were male. During a median follow-up of 27 months (interquartile range 16-63), 75 patients died. Fifty-one patients died within 30 days, 75 during long-term follow-up (median follow-up 27 months, minimum 5 months, maximum 125 months). Metrics of RV function were the strongest predictors of outcome, even stronger than left ventricular function ( P <0.001 for receiver operating characteristics comparisons). Specifically, RV free-wall strain was a powerful predictor univariately and after adjustment for clinical variables, Simplified Acute Physiology Score-3, tricuspid regurgitation, surgery type and duration with adjusted hazard ratios of 0.41 (95%CI 0.24-0.68; P =0.001) for 30-day mortality and 0.48 (95%CI 0.33-0.71; P <0.001) for long-term mortality for a 1-SD (SD=-6%) change in RV free-wall strain. Combined assessment of the additive EuroSCORE and RV free-wall strain improved risk classification by a net reclassification improvement of 57% for 30-day mortality ( P =0.01) and 56% for long-term mortality ( P =0.02) compared with the additive EuroSCORE alone. RV function is strongly linked to mortality, even after adjustment for baseline variables and clinical risk scores. RV performance improves

  10. A novel membrane inlet mass spectrometer method to measure ¹⁵NH4₄⁺ for isotope-enrichment experiments in aquatic ecosystems.

    Science.gov (United States)

    Yin, Guoyu; Hou, Lijun; Liu, Min; Liu, Zhanfei; Gardner, Wayne S

    2014-08-19

    Nitrogen (N) pollution in aquatic ecosystems has attracted much attention over the past decades, but the dynamics of this bioreactive element are difficult to measure in aquatic oxygen-transition environments. Nitrogen-transformation experiments often require measurement of (15)N-ammonium ((15)NH4(+)) ratios in small-volume (15)N-enriched samples. Published methods to determine N isotope ratios of dissolved ammonium require large samples and/or costly equipment and effort. We present a novel ("OX/MIMS") method to determine N isotope ratios for (15)NH4(+) in experimental waters previously enriched with (15)N compounds. Dissolved reduced (15)N (dominated by (15)NH4(+)) is oxidized with hypobromite iodine to nitrogen gas ((29)N2 and/or (30)N2) and analyzed by membrane inlet mass spectrometry (MIMS) to quantify (15)NH4(+) concentrations. The N isotope ratios, obtained by comparing the (15)NH4(+) to total ammonium (via autoanalyzer) concentrations, are compared to the ratios of prepared standards. The OX/MIMS method requires only small sample volumes of water (ca. 12 mL) or sediment slurries and is rapid, convenient, accurate, and precise (R(2) = 0.9994, p < 0.0001) over a range of salinities and (15)N/(14)N ratios. It can provide data needed to quantify rates of ammonium regeneration, potential ammonium uptake, and dissimilatory nitrate reduction to ammonium (DNRA). Isotope ratio results agreed closely (R = 0.998, P = 0.001) with those determined independently by isotope ratio mass spectrometry for DNRA measurements or by ammonium isotope retention time shift liquid chromatography for water-column N-cycling experiments. Application of OX/MIMS should simplify experimental approaches and improve understanding of N-cycling rates and fate in a variety of freshwater and marine environments.

  11. Membrane culture and reduced oxygen tension enhances cartilage matrix formation from equine cord blood mesenchymal stromal cells in vitro.

    Science.gov (United States)

    Co, C; Vickaryous, M K; Koch, T G

    2014-03-01

    Ongoing research is aimed at increasing cartilage tissue yield and quality from multipotent mesenchymal stromal cells (MSC) for the purpose of treating cartilage damage in horses. Low oxygen culture has been shown to enhance chondrogenesis, and novel membrane culture has been proposed to increase tissue yield and homogeneity. The objective of this study was to evaluate and compare the effect of reduced oxygen and membrane culture during in vitro chondrogenesis of equine cord blood (CB) MSC. CB-MSC (n = 5 foals) were expanded at 21% oxygen prior to 3-week differentiation in membrane or pellet culture at 5% and 21% oxygen. Assessment included histological examination (H&E, toluidine Blue, immunohistochemistry (IHC) for collagen type I and II), protein quantification by hydroxyproline assay and dimethylmethylene assay, and mRNA analysis for collagen IA1, collagen IIA1, collagen XA1, HIF1α and Sox9. Among treatment groups, 5% membrane culture produced neocartilage most closely resembling hyaline cartilage. Membrane culture resulted in increased wet mass, homogenous matrix morphology and an increase in total collagen content, while 5% oxygen culture resulted in higher GAG and type II collagen content. No significant differences were observed for mRNA analysis. Membrane culture at 5% oxygen produces a comparatively larger amount of higher quality neocartilage. Matrix homogeneity is attributed to a uniform diffusion gradient and reduced surface tension. Membrane culture holds promise for scale-up for therapeutic purposes, for cellular preconditioning prior to cytotherapeutic applications, and for modeling system for gas-dependent chondrogenic differentiation studies. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  12. Extracellular ultrathin fibers sensitive to intracellular reactive oxygen species: Formation of intercellular membrane bridges

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Se-Hui; Park, Jin-Young; Joo, Jung-Hoon; Kim, Young-Myeong; Ha, Kwon-Soo, E-mail: ksha@kangwon.ac.kr

    2011-07-15

    Membrane bridges are key cellular structures involved in intercellular communication; however, dynamics for their formation are not well understood. We demonstrated the formation and regulation of novel extracellular ultrathin fibers in NIH3T3 cells using confocal and atomic force microscopy. At adjacent regions of neighboring cells, phorbol 12-myristate 13-acetate (PMA) and glucose oxidase induced ultrathin fiber formation, which was prevented by Trolox, a reactive oxygen species (ROS) scavenger. The height of ROS-sensitive ultrathin fibers ranged from 2 to 4 nm. PMA-induced formation of ultrathin fibers was inhibited by cytochalasin D, but not by Taxol or colchicine, indicating that ultrathin fibers mainly comprise microfilaments. PMA-induced ultrathin fibers underwent dynamic structural changes, resulting in formation of intercellular membrane bridges. Thus, these fibers are formed by a mechanism(s) involving ROS and involved in formation of intercellular membrane bridges. Furthermore, ultrastructural imaging of ultrathin fibers may contribute to understanding the diverse mechanisms of cell-to-cell communication and the intercellular transfer of biomolecules, including proteins and cell organelles.

  13. Lipid engineering reveals regulatory roles for membrane fluidity in yeast flocculation and oxygen-limited growth

    Energy Technology Data Exchange (ETDEWEB)

    Degreif, Daniel [Joint BioEnergy Inst. (JBEI), Emeryville, CA (United States); Technical Univ. of Darmstadt (Germany); de Rond, Tristan [Joint BioEnergy Inst. (JBEI), Emeryville, CA (United States); Univ. of California, Berkeley, CA (United States); Bertl, Adam [Technical Univ. of Darmstadt (Germany); Keasling, Jay D. [Joint BioEnergy Inst. (JBEI), Emeryville, CA (United States); Univ. of California, Berkeley, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Technical Univ. of Denmark, Lyngby (Denmark); Budin, Itay [Joint BioEnergy Inst. (JBEI), Emeryville, CA (United States); Univ. of California, Berkeley, CA (United States)

    2017-03-18

    Cells modulate lipid metabolism in order to maintain membrane homeostasis. In this paper, we use a metabolic engineering approach to manipulate the stoichiometry of fatty acid unsaturation, a regulator of cell membrane fluidity, in Saccharomyces cerevisiae. Unexpectedly, reduced lipid unsaturation triggered cell-cell adhesion (flocculation), a phenomenon characteristic of industrial yeast but uncommon in laboratory strains. We find that ER lipid saturation sensors induce expression of FLO1 – encoding a cell wall polysaccharide binding protein – independently of its canonical regulator. In wild-type cells, Flo1p-dependent flocculation occurs under oxygen-limited growth, which reduces unsaturated lipid synthesis and thus serves as the environmental trigger for flocculation. Transcriptional analysis shows that FLO1 is one of the most highly induced genes in response to changes in lipid unsaturation, and that the set of membrane fluidity-sensitive genes is globally activated as part of the cell's long-term response to hypoxia during fermentation. Finally, our results show how the lipid homeostasis machinery of budding yeast is adapted to carry out a broad response to an environmental stimulus important in biotechnology.

  14. Metallic substrate materials for thin film oxygen transport membranes for application in a fossil power plant

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Y.; Baumann, S.; Sebold, D.; Meulenberg, W.A.; Stoever, D. [Forschungszentrum Juelich GmbH (DE). Inst. fuer Energieforschung (IEF) - IEF-1 Materials Synthesis and Processing

    2010-07-01

    La{sub 0.58}Sr{sub 0.4}CO{sub 0.2}Fe{sub 0.8}O{sub 3-{delta}} (LSCF58428) and Ba{sub 0.5}Sr{sub 0.5}CO{sub 0.8}Fe{sub 3-{delta}} (BSCF5582) exhibit high oxygen permeability due to their high ionic and electronic conductivity. For this reason they are under discussion for application in oxygen transport membranes (OTMs) in zero-emission power plants using oxyfuel technology. A thin film membrane which can increase the oxygen flux is beneficial and a structural substrate is required. Two types of Ni-base alloys were studied as substrate material candidates with a number of advantages, such as high strength, high temperature stability, easy joining and similar thermal expansion coefficient to the selected perovskite materials. Chemical compositions and thermal expansion coefficients of Ni-base alloys were measured in this study. LSCF58428 and BSCF5582 layers were screen printed on Ni-based alloys and co-fired at high temperature in air. The microstructure and element analysis of samples were characterized by scanning electron microscopy (SEM and EDX). A Ni-base alloy, MCrAlY, with a high Al content was the most suitable substrate material, and showed better chemical compatibility with perovskite materials at high temperature than Hastelloy X, which is a chromia-forming Ni-base alloy. A reaction occurred between Sr in the perovskite and the alumina surface layers on MCr-AlY. However, the reaction zone did not increase in thickness during medium-term annealing at 800 C in air. Hence, it is expected that this reaction will not prevent the application of MCr-AlY as a substrate material. (orig.)

  15. Local experience with extracorporeal membrane oxygenation in children with acute fulminant myocarditis.

    Directory of Open Access Journals (Sweden)

    Botao Ning

    Full Text Available To analyze the clinical effect of extracorporeal membrane oxygenation (ECMO in children with acute fulminant myocarditis, we retrospectively analyzed the data of five children with acute fulminant myocarditis in the intensive care unit (ICU at the Affiliated Children's Hospital, Zhejiang University from February 2009 to November 2012. The study group included two boys and three girls ranging in age from 9 to 13 years (median 10 years. Body weight ranged from 25 to 33 kg (mean 29.6 kg. They underwent extracorporeal membrane oxygenation (ECMO through a venous-arterial ECMO model with an average ECMO supporting time of 89.8 h (40-142 h. Extracorporeal circulation was established in all five children. After treatment with ECMO, the heart rate, blood pressure, and oxygen saturation were greatly improved in the four children who survived. These four children were successfully weaned from ECMO and discharged from hospital machine-free, for a survival rate of 80% (4/5. One child died still dependent on the machine. Cause of death was irrecoverable cardiac function and multiple organ failure. Complications during ECMO included three cases of suture bleeding, one case of acute hemolytic renal failure and suture bleeding, and one case of hyperglycemia. During the follow-up period of 4-50 months, the four surviving children recovered with normal cardiac function and no abnormal functions of other organs. The application of ECMO in acute fulminant myocarditis, even in local centers that experience low incidence of this disease, remains an effective approach. Larger studies to determine optimal timing of placement on ECMO to guide local centers are warranted.

  16. Hybrid configurations via percutaneous access for extracorporeal membrane oxygenation: a single-center experience.

    Science.gov (United States)

    Biscotti, Mauer; Lee, Alison; Basner, Robert C; Agerstrand, Cara; Abrams, Darryl; Brodie, Daniel; Bacchetta, Matthew

    2014-01-01

    Use of extracorporeal membrane oxygenation (ECMO) in adults has surged in recent years. Typical configurations are venovenous (VV), which provides respiratory support, or venoarterial (VA), which provides both respiratory and circulatory support. In patients supported with VV ECMO who develop hemodynamic compromise, an arterial limb can be added (venovenous-arterial ECMO) to provide additional circulatory support. For patients on VA ECMO who develop concomitant respiratory failure in the setting of some residual cardiac function, an oxygenated reinfusion limb can be added to the internal jugular vein (venoarterial-venous ECMO) to improve oxygen delivery to the cerebral and coronary circulation. Such hybrid configurations can provide differential support for various forms of cardiopulmonary failure. We describe 21 patients who ultimately received a hybrid configuration at our institution between 2012 and 2013. Eight patients (38.1%) died during ECMO support, four patients (19.0%) died after decannulation but before hospital discharge, and nine patients (42.9%) survived to hospital discharge. Our modest survival rate is likely related to the complexity and severity of illness of these patients, and this relative success suggests that hybrid configurations can be effective. It serves patients well to maintain a flexible and adaptable approach to ECMO configurations for their variable cardiopulmonary needs.

  17. Successful Treatment of Severe Carbon Monoxide Poisoning and Refractory Shock Using Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Teerapuncharoen, Krittika; Sharma, Nirmal S; Barker, Andrew B; Wille, Keith M; Diaz-Guzman, Enrique

    2015-09-01

    Carbon monoxide (CO) is the most common cause of poisoning and poisoning-related death in the United States. It is a tasteless and odorless poisonous gas produced from incomplete combustion of hydrocarbons, such as those produced by cars and heating systems. CO rapidly binds to hemoglobin to form carboxyhemoglobin, leading to tissue hypoxia, multiple-organ failure, and cardiovascular collapse. CO also binds to myocardial myoglobin, preventing oxidative phosphorylation in cardiac mitochondria and resulting in cardiac ischemia or stunning and cardiogenic pulmonary edema. Treatment of CO poisoning is mainly supportive, and supplemental oxygen remains the cornerstone of therapy, whereas hyperbaric oxygen therapy is considered for patients with evidence of neurological and myocardial injury. Extracorporeal membrane oxygenation (ECMO) has been utilized effectively in patients with respiratory failure and hemodynamic instability, but its use has rarely been reported in patients with CO poisoning. We report the successful use of venoarterial ECMO in a patient with severe CO poisoning and multiple-organ failure. Copyright © 2015 by Daedalus Enterprises.

  18. Nanoporous MoS2 monolayer as a promising membrane for purifying hydrogen and enriching methane

    Science.gov (United States)

    Zhang, Yadong; Meng, Zhaoshun; Shi, Qi; Gao, Haiqi; Liu, Yuzhen; Wang, Yunhui; Rao, Dewei; Deng, Kaiming; Lu, Ruifeng

    2017-09-01

    We present a theoretical prediction of a highly efficient membrane for hydrogen purification and natural gas upgrading, i.e. laminar MoS2 material with triangular sulfur-edged nanopores. We calculated from first principles the diffusion barriers of H2 and CO2 across monolayer MoS2 to be, respectively, 0.07 eV and 0.17 eV, which are low enough to warrant their great permeability. The permeance values for H2 and CO2 far exceed the industrially accepted standard. Meanwhile, such a porous MoS2 membrane shows excellent selectivity in terms of H2/CO, H2/N2, H2/CH4, and CO2/CH4 separation (>103, >  103, >  106, and  >  104, respectively) at room temperature. We expect that the findings in this work will expedite theoretical or experimental exploration on gas separation membranes based on transition metal dichalcogenides.

  19. Basic technology for {sup 6}Li enrichment using an ionic-liquid impregnated organic membrane

    Energy Technology Data Exchange (ETDEWEB)

    Hoshino, Tsuyoshi, E-mail: hoshino.tsuyoshi@jaea.go.jp [Blanket Irradiation and Analysis Group, Fusion Research and Development Directorate, Japan Atomic Energy Agency, 4002, Narita-cho, Oarai-machi, Higashi Ibaraki-gun, Ibaraki 311-1393 (Japan); Terai, Takayuki [The Institute of Engineering Innovation and Department of Nuclear Engineering and Management School of Engineering, The University of Tokyo, 2-11-16 Yayoi, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2011-10-01

    The tritium needed as a fuel for fusion reactors is produced by the neutron capture reaction of lithium-6 ({sup 6}Li) in tritium breeding materials. However, natural Li contains only about 7.6 at.% {sup 6}Li. In this paper, a new lithium isotope separation technique using an ionic-liquid impregnated organic membrane is proposed. In order to separate and concentrate lithium isotopes, only lithium ions are able to move through the membrane by electrodialysis between the cathode and the anode in lithium solutions. Preliminary experiments of lithium isotope separation were conducted using this phenomenon. Organic membranes impregnated with TMPA-TFSI and PP13-TFSI as ionic liquids were prepared, and the relationship between the {sup 6}Li separation coefficient and the applied electrodialytic conditions was evaluated using them. The results showed that the {sup 6}Li isotope separation coefficient in this method (about 1.1-1.4) was larger than that in the mercury amalgam method (about 1.06).

  20. Ceramide-Enriched Membrane Domains in Red Blood Cells and the Mechanism ofSphingomyelinase-Induced Hot-Cold Hemolysis

    DEFF Research Database (Denmark)

    Montes, Ruth; Lopez, David; Sot, Jesus

    2008-01-01

    Hot-cold hemolysis is the phenomenon whereby red blood cells, preincubated at 37 °C in the presence of certain agents, undergo rapid hemolysis when transferred to 4 °C. The mechanism of this phenomenon is not understood. PlcHR2, a phospholipase C/sphingomyelinase from Pseudomonas aeruginosa......) but also in goat erythrocytes, which lack PC. However, in horse erythrocytes, with a large proportion of PC and almost no SM, hot-cold hemolysis induced by PlcHR2 is not observed. Fluorescence microscopy observations confirm the formation of ceramide-enriched domains as a result of PlcHR2 activity. After......-cold hemolysis. Differential scanning calorimetry of erytrocyte membranes treated with PlcHR2 demonstrates the presence of ceramide-rich domains that are rigid at 4 °C but fluid at 37 °C. Ceramidase treatment causes the disapperance of the calorimetric signal assigned to ceramide-rich domains. Finally...

  1. Accurate control of oxygen level in cells during culture on silicone rubber membranes with application to stem cell differentiation.

    Science.gov (United States)

    Powers, Daryl E; Millman, Jeffrey R; Bonner-Weir, Susan; Rappel, Michael J; Colton, Clark K

    2010-01-01

    Oxygen level in mammalian cell culture is often controlled by placing culture vessels in humidified incubators with a defined gas phase partial pressure of oxygen (pO(2gas)). Because the cells are consuming oxygen supplied by diffusion, a difference between pO(2gas) and that experienced by the cells (pO(2cell)) arises, which is maximal when cells are cultured in vessels with little or no oxygen permeability. Here, we demonstrate theoretically that highly oxygen-permeable silicone rubber membranes can be used to control pO(2cell) during culture of cells in monolayers and aggregates much more accurately and can achieve more rapid transient response following a disturbance than on polystyrene and fluorinated ethylene-propylene copolymer membranes. Cell attachment on silicone rubber was achieved by physical adsorption of fibronectin or Matrigel. We use these membranes for the differentiation of mouse embryonic stem cells to cardiomyocytes and compare the results with culture on polystyrene or on silicone rubber on top of polystyrene. The fraction of cells that are cardiomyocyte-like increases with decreasing pO(2) only when using oxygen-permeable silicone membrane-based dishs, which contract on silicone rubber but not polystyrene. The high permeability of silicone rubber results in pO(2cell) being equal to pO(2gas) at the tissue-membrane interface. This, together with geometric information from histological sections, facilitates development of a model from which the pO(2) distribution within the resulting aggregates is computed. Silicone rubber membranes have significant advantages over polystyrene in controlling pO(2cell), and these results suggest they are a valuable tool for investigating pO(2) effects in many applications, such as stem cell differentiation. Copyright 2009 American Institute of Chemical Engineers

  2. Polymerization of Phenylacetylene-Based Monodendrons with Alkoxy Peripheral Groups and Oxygen/Nitrogen Permeation Behavior of Their Membranes

    Directory of Open Access Journals (Sweden)

    Takashi Kaneko

    2012-01-01

    Full Text Available Monodendron monomers with alkoxy peripheral groups were synthesized, and the focal point of monodendrons, terminal acetylene, was polymerized with rhodium catalyst to yield corresponding polydendrons with a high molecular weight. The polydendrons were soluble in common organic solvents and readily formed membranes. Oxygen permselectivity was improved in the polydendrons with a space-persistent dendritic crowd. It was found that the well-defined dendritic and rod-like structure of the polydendrons was useful for permselective membrane.

  3. Preparation of rat gastric heavy and light microsomal membranes enriched in (H+-K+)-ATPase using 2H2O and Percoll gradients

    International Nuclear Information System (INIS)

    Im, W.B.; Davis, J.P.; Blakeman, D.P.

    1985-01-01

    Gastric heavy microsomal membranes highly enriched in (H + -K + )-ATPase were obtained from cimetidine- or carbachol-treated rats through 2 H 2 O and Percoll gradient centrifugations. Both the resting (cimetidine-treated) and the stimulated (carbachol-treated) heavy membranes which presumably represent the apical membrane of gastric parietal cells were enriched with the polypeptides of 81,000 and 45,000 besides that of 93,000 representing (H + -K + )-ATPase. No apparent differences could be detected between the resting and the stimulated heavy membranes in their polypeptide profiles or their specific activity of (H + -K + )-ATPase. Nevertheless, the level of 86 RbCl uptake was greater in the stimulated than the resting heavy microsomal membrane vesicles. The light gastric microsomes which abound in intracellular tubulovesicles containing reserve (H + -K + )-ATPase as isolated from cimetidine-treated rats were similarly purified with respect to (H + -K + )-ATPase. The purified light gastric membranes were largely devoid of the polypeptides of 81,000 and 45,000 found in the heavy gastric membranes. These observations further support the current hypothesis that secretagogues bring about changes in the environment of (H + -K + )-ATPase and induce KCl permeability in the apical membrane of the parietal cells, although at present the authors have been unable to identify the polypeptide(s) responsible for the KCl pathway

  4. Undressing of Waddlia chondrophila to enrich its outer membrane proteins to develop a new species-specific ELISA

    Directory of Open Access Journals (Sweden)

    J. Lienard

    2014-01-01

    Full Text Available Waddlia chondrophila, an obligate intracellular bacterium of the Chlamydiales order, is considered as an agent of bovine abortion and a likely cause of miscarriage in humans. Its role in respiratory diseases was questioned after the detection of its DNA in clinical samples taken from patients suffering from pneumonia or bronchiolitis. To better define the role of Waddlia in both miscarriage and pneumonia, a tool allowing large-scale serological investigations of Waddlia seropositivity is needed. Therefore, enriched outer membrane proteins of W. chondrophila were used as antigens to develop a specific ELISA. After thorough analytical optimization, the ELISA was validated by comparison with micro-immunofluorescence and it showed a sensitivity above 85% with 100% specificity. The ELISA was subsequently applied to human sera to specify the role of W. chondrophila in pneumonia. Overall, 3.6% of children showed antibody reactivity against W. chondrophila but no significant difference was observed between children with and without pneumonia. Proteomic analyses were then performed using mass spectrometry, highlighting members of the outer membrane protein family as the dominant proteins. The major Waddlia putative immunogenic proteins were identified by immunoblot using positive and negative human sera. The new ELISA represents an efficient tool with high throughput applications. Although no association with pneumonia and Waddlia seropositivity was observed, this ELISA could be used to specify the role of W. chondrophila in miscarriage and in other diseases.

  5. Oxygen permeation properties of dense Bi1.5Er0.5O3-Ag cermet membranes

    NARCIS (Netherlands)

    ten Elshof, Johan E.; Nguyen, N.Q.; den Otter, M.W.; Bouwmeester, Henricus J.M.

    1997-01-01

    Oxygen permeation experiments were performed on dense mixed-conducting ceramic-metal composite membranes (thickness 0.2 to 2 mm) Bi1.5Er0.5O3-Ag with 10.0, 27.8, and 40.0 volume percent (v/o) silver, respectively, in the temperature range 873 to 993 K and oxygen partial pressure range 10–3.5 to 1

  6. Salvage intraosseous thrombolysis and extracorporeal membrane oxygenation for massive pulmonary embolism

    Directory of Open Access Journals (Sweden)

    Luke Cameron Northey

    2015-01-01

    Full Text Available Intraosseous access is an alternative route of pharmacotherapy during cardiopulmonary resuscitation. Extracorporeal membrane oxygenation (ECMO provides cardiac and respiratory support when conventional therapies fail. This case reports the use of intraosseous thrombolysis and ECMO in a patient with acute massive pulmonary embolism (PE. A 34-year-old female presented to the emergency department with sudden onset severe shortness of breath. Due to difficulty establishing intravenous access, an intraosseous needle was inserted into the left tibia. Echocardiography identified severe right ventricular dilatation with global systolic impairment and failure, indicative of PE. Due to the patient′s hemodynamic compromise a recombinant tissue plasminogen activator (Alteplase bolus was administered through the intraosseous route. After transfer to the intensive care unit, venous-arterial ECMO was initiated as further therapy. The patient recovered and was discharged 36 days after admission. This is the first report of combination intraosseous thrombolysis and ECMO as salvage therapy for massive PE.

  7. The Use of Extracorporeal Membrane Oxygenation in the Surgical Repair of Bronchial Rupture

    Directory of Open Access Journals (Sweden)

    Ju-Hee Park

    2016-02-01

    Full Text Available Extracorporeal membrane oxygenation (ECMO has been used successfully in critically ill patients with traumatic lung injury and offers an additional treatment modality. ECMO is mainly used as a bridge treatment to delayed surgical management; however, only a few case reports have presented the successful application of ECMO as intraoperative support during the surgical repair of traumatic bronchial injury. A 38-year-old man visited our hospital after a blunt chest trauma. His chest imaging showed hemopneumothorax in the left hemithorax and a finding suspicious for left main bronchus rupture. Bronchoscopy was performed and confirmed a tear in the left main bronchus and a congenital tracheal bronchus. We decided to provide venovenous ECMO support during surgery for bronchial repair. We successfully performed main bronchial repair in this traumatic patient with a congenital tracheal bronchus. We suggest that venovenous ECMO offers a good option for the treatment of bronchial rupture when adequate ventilation is not possible.

  8. Refractory Septic Shock Treated with Nephrectomy under the Support of Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Young Kun Lee

    2015-08-01

    Full Text Available Conventional medical therapies have not been very successful in treating adults with refractory septic shock. The effects of direct hemoperfusion using polymyxin B and veno-arterial extracorporeal membrane oxygenation (ECMO for refractory septic shock remain uncertain. A 66-year-old man was admitted to the emergency department and suffered from sepsis-induced hemodynamic collapse. For hemodynamic improvement, we performed direct hemoperfusion using polymyxin B. Computed tomography scan of this patient revealed emphysematous pyelonephritis (EPN, for which he underwent emergent nephrectomy with veno-arterial ECMO support. To the best of our knowledge, this is the first report of successful treatment of EPN with refractory septic shock using polymyxin B hemoperfusion and nephrectomy under the support of ECMO.

  9. H3N2 Virus as Causative Agent of ARDS Requiring Extracorporeal Membrane Oxygenation Support

    Directory of Open Access Journals (Sweden)

    Adriano Peris

    2014-01-01

    Full Text Available Pandemic influenza virus A(H1N1 2009 was associated with a higher risk of viral pneumonia in comparison with seasonal influenza viruses. The influenza season 2011-2012 was characterized by the prevalent circulation of influenza A(H3N2 viruses. Whereas most H3N2 patients experienced mild, self-limited influenza-like illness, some patients were at increased risk for influenza complications because of age or underlying medical conditions. Cases presented were patients admitted to the Intensive Care Unit (ICU of ECMO referral center (Careggi Teaching Hospital, Florence, Italy. Despite extracorporeal membrane oxygenation treatment (ECMO, one patient with H3N2-induced ARDS did not survive. Our experience suggests that viral aetiology is becoming more important and hospitals should be able to perform a fast differential diagnosis between bacterial and viral aetiology.

  10. Cerebral Pathophysiology in Extracorporeal Membrane Oxygenation: Pitfalls in Daily Clinical Management

    Directory of Open Access Journals (Sweden)

    Syed Omar Kazmi

    2018-01-01

    Full Text Available Extracorporeal membrane oxygenation (ECMO is a life-saving technique that is widely being used in centers throughout the world. However, there is a paucity of literature surrounding the mechanisms affecting cerebral physiology while on ECMO. Studies have shown alterations in cerebral blood flow characteristics and subsequently autoregulation. Furthermore, the mechanical aspects of the ECMO circuit itself may affect cerebral circulation. The nature of these physiological/pathophysiological changes can lead to profound neurological complications. This review aims at describing the changes to normal cerebral autoregulation during ECMO, illustrating the various neuromonitoring tools available to assess markers of cerebral autoregulation, and finally discussing potential neurological complications that are associated with ECMO.

  11. Ethical Considerations for Care of the Child Undergoing Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Carter, Martha A

    2017-02-01

    Extracorporeal membrane oxygenation (ECMO) is a complex, highly technical surgical procedure that can offer hope for children born with congenital heart defects. The procedure may only briefly prolong a life, has limited potential for decreasing mortality, and may lead to serious complications, however. Perioperative nurses play an important role in caring for the child who requires ECMO. They are involved in assessing the child, implementing the plan of care, and facilitating communication between the child's family members and the health care team. Thus, perioperative nurses have a responsibility to consider the broad range of ethical issues associated with the procedure. By examining the ethical concepts of beneficence, nonmaleficence, autonomy, justice, and moral distress, the perioperative nurse can better understand the dilemmas that can affect the care and outcome of the critically ill child who requires ECMO. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  12. A brief clinical case of monitoring of oxygenator performance and patient-machine interdependency during prolonged veno-venous extracorporeal membrane oxygenation.

    Science.gov (United States)

    Belliato, Mirko; Degani, Antonella; Buffa, Antonino; Sciutti, Fabio; Pagani, Michele; Pellegrini, Carlo; Iotti, Giorgio Antonio

    2017-10-01

    Monitoring veno-venous extracorporeal membrane oxygenation (vvECMO) during 76 days of continuous support in a 42-years old patient with end-stage pulmonary disease, listed for double-lung transplantation. Applying a new monitor (Landing ® , Eurosets, Medolla, Italy) and describing how measured and calculated parameters can be used to understand the variable interdependency between artificial membrane lung (ML) and patient native lung (NL). During vvECMO, in order to understand how the respiratory function is shared between ML and NL, ideally we should obtain data about oxygen transfer and CO 2 removal, both by ML and NL. Measurements for NL can be made on the mechanical ventilator. Measurements for ML are typically made from gas analysis on blood samples drawn from the ECMO system before and after the oxygenator, and therefore are non-continuous. Differently, the Landing monitor provides a continuous measurement of the oxygen transfer from the ML, combined with hemoglobin level, saturation of drained blood and saturation of reinfused blood. Moreover, the Landing monitor provides hemodynamics data about circulation through the ECMO system, with blood flow, pre-oxygenator pressure and post-oxygenator pressure. Of note, measurements include the drain negative pressure, whose monitoring may be particularly useful to prevent hemolysis. Real-time monitoring of vvECMO provides data helpful to understand the complex picture of a patient with severely damaged lungs on one side and an artificial lung on the other side. Data from vvECMO monitoring may help to adapt the settings of both mechanical ventilator and vvECMO. Data about oxygen transfer by the oxygenator are important to evaluate the performance of the device and may help to avoid unnecessary replacements, thus reducing risks and costs.

  13. Dose-rate and oxygen effects in models of lipid membranes: linoleic acid

    Energy Technology Data Exchange (ETDEWEB)

    Raleigh, J A; Kremers, W; Gaboury, B [Atomic Energy of Canada Ltd., Pinawa, Manitoba. Whiteshell Nuclear Research Establishment

    1977-03-01

    Cellular membranes have been suggested as possible loci for the development of the oxygen effect in radiobiology. Unsaturated lipids from membranes are subject to very efficient radiation-induced peroxidation, and the deleterious effects generally associated with lipid autoxidation could be initiated by ionizing radiation. Oxidative damage in lipids was characterized not only by high yields but also by a profound dose-rate effect. At dose-rates of x irradiation below 100 rad/min, a very sharp rise occurred in oxidative damage. This damage has been quantified spectrophotometrically in terms of diene conjugation (O.D. 234 mm) and chromatographically in terms of specific 9- and 13-hydroperoxide formation in linoleic acid micelles. Radical scavenging experiments indicated that hydroxyl radical attack initiated the oxidative damage. Dimethyl sulphoxide is exceptional in that it did not protect, but sensitized, linoleic acid to radiation-induced peroxidation. The yields of hydroperoxides were substantial (G = 10 to 40) and could be related to biological changes known to be effected by autoxidizing lipids.

  14. Mobile Extracorporeal Membrane Oxygenation Teams: The North American Versus the European Experience.

    Science.gov (United States)

    Nwozuzu, Adambeke; Fontes, Manuel L; Schonberger, Robert B

    2016-12-01

    To evaluate differences in the inclusion of anesthesiologists in mobile extracorporeal membrane oxygenation (ECMO) teams between North American and European centers. A retrospective review of North American versus European mobile ECMO teams. The search terms used to identify relevant articles were the following: "extracorporeal membrane transport," "mobile ECMO," and "interhospital transport." MEDLINE review of articles. None. None. Between 1986 and 2015, 25 articles were published that reported the personnel makeup of mobile ECMO teams in North America and Europe: 6 from North American centers and 19 from European centers. The included articles reported a total of 1,329 cases: 389 (29%) adult-only cohorts and 940 (71%) mixed-age cohorts. Among North American studies, 0 of 6 (0%) reported the presence of an anesthesiologist on the mobile ECMO team in contrast to European studies, in which 10 of 19 (53%) reported the inclusion of an anesthesiologist (Fisher exact p for difference = 0.05). In terms of number of cases, this discrepancy translated to 543 total cases in North America (all without an anesthesiologist) and 499 cases in Europe (37%) including an anesthesiologist on the team (Fisher exact p for difference<0.001). This study demonstrated significant geographic discrepancies in the inclusion of anesthesiologists on mobile ECMO teams, with European centers more likely to incorporate an anesthesiologist into the mobile ECMO process compared with North American centers. Copyright © 2016. Published by Elsevier Inc.

  15. Effects of oxygen-enriched air on cognitive performance during SCUBA-diving - an open-water study.

    Science.gov (United States)

    Brebeck, Anne-Kathrin; Deussen, Andreas; Schmitz-Peiffer, Henning; Range, Ursula; Balestra, Costantino; Cleveland, Sinclair; Schipke, Jochen D

    2017-01-01

    Backround: Nitrogen narcosis impairs cognitive function, a fact relevant during SCUBA-diving. Oxygen-enriched air (nitrox) became popular in recreational diving, while evidence of its advantages over air is limited. Compare effects of nitrox28 and air on two psychometric tests. In this prospective, double-blind, open-water study, 108 advanced divers (38 females) were randomized to an air or a nitrox-group for a 60-min dive to 24 m salt water. Breathing gas effects on cognitive performance were assessed during the dive using a short- and long-term memory test and a number connection test. Nitrox28 divers made fewer mistakes only on the long-term memory test (p = 0.038). Female divers remembered more items than male divers (p < 0.001). There were no significant differences in the number connection test between the groups. Likely owing to the comparatively low N 2 reduction and the conservative dive, beneficial nitrox28 effects to diver performance were moderate but could contribute to diving safety.

  16. The effect of intraoral suction on oxygen-enriched surgical environments: a mechanism for reducing the risk of surgical fires.

    Science.gov (United States)

    VanCleave, Andrea M; Jones, James E; McGlothlin, James D; Saxen, Mark A; Sanders, Brian J; Vinson, LaQuia A

    2014-01-01

    In this study, a mechanical model was applied in order to replicate potential surgical fire conditions in an oxygen-enriched environment with and without high-volume suction typical for dental surgical applications. During 41 trials, 3 combustion events were measured: an audible pop, a visible flash of light, and full ignition. In at least 11 of 21 trials without suction, all 3 conditions were observed, sometimes with an extent of fire that required early termination of the experimental trial. By contrast, in 18 of 20 with-suction trials, ignition did not occur at all, and in the 2 cases where ignition did occur, the fire was qualitatively a much smaller, candle-like flame. Statistically comparing these 3 combustion events in the no-suction versus with-suction trials, ignition (P = .0005), audible pop (P = .0211), and flash (P = .0092) were all significantly more likely in the no-suction condition. These results suggest a possible significant and new element to be added to existing surgical fire safety protocols toward making surgical fires the "never-events" they should be.

  17. Effect of hydrophobic additive on oxygen transport in catalyst layer of proton exchange membrane fuel cells

    Science.gov (United States)

    Wang, Shunzhong; Li, Xiaohui; Wan, Zhaohui; Chen, Yanan; Tan, Jinting; Pan, Mu

    2018-03-01

    Oxygen transport resistance (OTR) is a critical factor influencing the performance of proton exchange membrane fuel cells (PEMFCs). In this paper, an effective method to reduce the OTR of catalyst layers (CLs) by introducing a hydrophobic additive into traditional CLs is proposed. A low-molecular-weight polytetrafluoroethylene (PTFE) is selected for its feasibility to prepare an emulsion, which is mixed with a traditional catalyst ink to successfully fabricate the CL with PTFE of 10 wt%. The PTFE film exists in the mesopores between the carbon particles. The limiting current of the hydrophobic CL was almost 4000 mA/cm2, which is 500 mA/cm2 higher than that of the traditional CL. PTFE reduces the OTR of the CL in the dry region by as much as 24 s/m compared to the traditional CL and expands the dry region from 2000 mA/cm2 in the traditional CL to 2500 mA/cm2. Furthermore, the CL with the hydrophobic agent can improve the oxygen transport in the wet region (>2000 mA/cm2) more effectively than that in the dry region. All these results indicate that the CL with the hydrophobic agent shows a superior performance in terms of optimizing water management and effectively reduces the OTR in PEMFCs.

  18. Macro- and micronutrient disposition in an ex vivo model of extracorporeal membrane oxygenation.

    Science.gov (United States)

    Estensen, Kristine; Shekar, Kiran; Robins, Elissa; McDonald, Charles; Barnett, Adrian G; Fraser, John F

    2014-12-01

    Extracorporeal membrane oxygenation (ECMO) circuits have been shown to sequester circulating blood compounds such as drugs based on their physicochemical properties. This study aimed to describe the disposition of macro- and micronutrients in simulated ECMO circuits. Following baseline sampling, known quantities of macro- and micronutrients were injected post oxygenator into ex vivo ECMO circuits primed with the fresh human whole blood and maintained under standard physiologic conditions. Serial blood samples were then obtained at 1, 30 and 60 min and at 6, 12 and 24 h after the addition of nutrients, to measure the concentrations of study compounds using validated assays. Twenty-one samples were tested for thirty-one nutrient compounds. There were significant reductions (p single-dose ex vivo circuit study. Most significantly, there is potential for circuit loss of essential amino acid isoleucine and lipid soluble vitamins (A and E) in the ECMO circuit, and the mechanisms for this need further exploration. While the reductions in glucose concentrations and an increase in other macro- and micronutrient concentrations probably reflect cellular metabolism and breakdown, the decrement in arginine and glutamine concentrations may be attributed to their enzymatic conversion to ornithine and glutamate, respectively. While the results are generally reassuring from a macronutrient perspective, prospective studies in clinical subjects are indicated to further evaluate the influence of ECMO circuit on micronutrient concentrations and clinical outcomes.

  19. CoPd x oxygen reduction electrocatalysts for polymer electrolyte membrane and direct methanol fuel cells

    International Nuclear Information System (INIS)

    Mustain, William E.; Kepler, Keith; Prakash, Jai

    2007-01-01

    The electrochemical activity of carbon-supported cobalt-palladium alloy electrocatalysts of various compositions have been investigated for the oxygen reduction reaction in a 5 cm 2 single cell polymer electrolyte membrane fuel cell. The polarization experiments have been conducted at various temperatures between 30 and 60 deg. C and the reduction performance compared with data from a commercial Pt catalyst under identical conditions. Investigation of the catalytic activity of the CoPd x PEMFC system with varying composition reveals that a nominal cobalt-palladium atomic ratio of 1:3, CoPd 3 , exhibits the best performance of all studied catalysts, exhibiting a catalytic activity comparable to the commercial Pt catalyst. The ORR on CoPd 3 has a low activation energy, 52 kJ/mol, and a Tafel slope of approximately 60 mV/decade, indicating that the rate-determining step is a chemical step following the first electron transfer step and may involve the breaking of the oxygen bond. The CoPd 3 catalyst also exhibits excellent chemical stability, with the open circuit cell voltage decreasing by only 3% and the observed current decreasing by only 10% at 0.8 V over 25 h. The CoPd 3 catalyst also exhibits superior tolerance to methanol crossover poisoning than Pt

  20. Adult venovenous extracorporeal membrane oxygenation for severe respiratory failure: Current status and future perspectives

    Directory of Open Access Journals (Sweden)

    Ayan Sen

    2016-01-01

    Full Text Available Extracorporeal membrane oxygenation (ECMO for severe acute respiratory failure was proposed more than 40 years ago. Despite the publication of the ARDSNet study and adoption of lung protective ventilation, the mortality for acute respiratory failure due to acute respiratory distress syndrome has continued to remain high. This technology has evolved over the past couple of decades and has been noted to be safe and successful, especially during the worldwide H1N1 influenza pandemic with good survival rates. The primary indications for ECMO in acute respiratory failure include severe refractory hypoxemic and hypercarbic respiratory failure in spite of maximum lung protective ventilatory support. Various triage criteria have been described and published. Contraindications exist when application of ECMO may be futile or technically impossible. Knowledge and appreciation of the circuit, cannulae, and the physiology of gas exchange with ECMO are necessary to ensure lung rest, efficiency of oxygenation, and ventilation as well as troubleshooting problems. Anticoagulation is a major concern with ECMO, and the evidence is evolving with respect to diagnostic testing and use of anticoagulants. Clinical management of the patient includes comprehensive critical care addressing sedation and neurologic issues, ensuring lung recruitment, diuresis, early enteral nutrition, treatment and surveillance of infections, and multisystem organ support. Newer technology that delinks oxygenation and ventilation by extracorporeal carbon dioxide removal may lead to ultra-lung protective ventilation, avoidance of endotracheal intubation in some situations, and ambulatory therapies as a bridge to lung transplantation. Risks, complications, and long-term outcomes and resources need to be considered and weighed in before widespread application. Ethical challenges are a reality and a multidisciplinary approach that should be adopted for every case in consideration.

  1. Adult venovenous extracorporeal membrane oxygenation for severe respiratory failure: Current status and future perspectives.

    Science.gov (United States)

    Sen, Ayan; Callisen, Hannelisa E; Alwardt, Cory M; Larson, Joel S; Lowell, Amelia A; Libricz, Stacy L; Tarwade, Pritee; Patel, Bhavesh M; Ramakrishna, Harish

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) for severe acute respiratory failure was proposed more than 40 years ago. Despite the publication of the ARDSNet study and adoption of lung protective ventilation, the mortality for acute respiratory failure due to acute respiratory distress syndrome has continued to remain high. This technology has evolved over the past couple of decades and has been noted to be safe and successful, especially during the worldwide H1N1 influenza pandemic with good survival rates. The primary indications for ECMO in acute respiratory failure include severe refractory hypoxemic and hypercarbic respiratory failure in spite of maximum lung protective ventilatory support. Various triage criteria have been described and published. Contraindications exist when application of ECMO may be futile or technically impossible. Knowledge and appreciation of the circuit, cannulae, and the physiology of gas exchange with ECMO are necessary to ensure lung rest, efficiency of oxygenation, and ventilation as well as troubleshooting problems. Anticoagulation is a major concern with ECMO, and the evidence is evolving with respect to diagnostic testing and use of anticoagulants. Clinical management of the patient includes comprehensive critical care addressing sedation and neurologic issues, ensuring lung recruitment, diuresis, early enteral nutrition, treatment and surveillance of infections, and multisystem organ support. Newer technology that delinks oxygenation and ventilation by extracorporeal carbon dioxide removal may lead to ultra-lung protective ventilation, avoidance of endotracheal intubation in some situations, and ambulatory therapies as a bridge to lung transplantation. Risks, complications, and long-term outcomes and resources need to be considered and weighed in before widespread application. Ethical challenges are a reality and a multidisciplinary approach that should be adopted for every case in consideration.

  2. A highly phosphorylated subpopulation of insulin-like growth factor II/mannose 6-phosphate receptors is concentrated in a clathrin-enriched plasma membrane fraction

    International Nuclear Information System (INIS)

    Corvera, S.; Folander, K.; Clairmont, K.B.; Czech, M.P.

    1988-01-01

    Insulin-like growth factor II (IGF-II)/mannose 6-phosphate (Man-6-P) receptors immunoprecipitated from purified plasma membranes of 32 P-labeled rat adipocytes are markedly heterogenous in their phosphorylation state. Approximately 80% of the plasma membrane receptors are solubilized in 1% (vol/vol) Triton X-100 and are phosphorylated on serine residues at a stoichiometry of ∼ 0.1-0.2 mol of phosphate per mol of receptor. In contrast, 15-20% of the receptors are Triton X-100-insoluble and are phosphorylated on serine and threonine residues at ∼ 4 or 5 mol of phosphate per mol of receptor. This Triton X-100-insoluble membrane subfraction contains only 5% of the total plasma membrane protein and yet contains all of the clathrin heavy chain associated with plasma membrane. Based on the relative yields of protein in the detergent-insoluble material, IGF-II/Man-6-P receptors are concentrated ∼ 3-fold in this clathrin-enriched subfraction. Taken together, these results indicate that insulin decreases the phosphorylation state of a highly phosphorylated subpopulation of IGF-II/Man-6-P receptors on the plasma membrane. In addition, insulin action may prevent the concentration of these receptors in a clathrin-enriched membrane subfraction

  3. A novel ion transport membrane reactor for fundamental investigations of oxygen permeation and oxy-combustion under reactive flow conditions

    KAUST Repository

    Kirchen, Patrick

    2013-01-01

    Ion transport membrane (ITM) reactors present an attractive technology for combined air separation and fuel conversion in applications such as syngas production, oxidative coupling or oxy-combustion, with the promise of lower capital and operating costs, as well higher product selectivities than traditional technologies. The oxygen permeation rate through a given ITM is defined by the membrane temperature and oxygen chemical potential difference across it. Both of these parameters can be strongly influenced by thermochemical reactions occurring in the vicinity of the membrane, though in the literature they are often characterized in terms of the well mixed product stream at the reactor exit. This work presents the development of a novel ITM reactor for the fundamental investigation of the coupling between fuel conversion and oxygen permeation under well defined fluid dynamic and thermodynamic conditions, including provisions for spatially resolved, in-situ investigations. A planar, finite gap stagnation flow reactor with optical and probe access to the reaction zone is used to facilitate in-situ measurements and cross-validation with detailed numerical simulations. Using this novel reactor, baseline measurements are presented to elucidate the impact of the sweep gas fuel (CH4) fraction on the oxygen permeation and fuel conversion. In addition, the difference between well-mixed gas compositions measured at the reactor outlet and those measured in the vicinity of the membrane surface are discussed, demonstrating the unique utility of the reactor. © 2012 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

  4. Tailoring the porosity and shrinkage of extruded MgO support tubes for oxygen separation membranes by thermoplastic feedstock development

    DEFF Research Database (Denmark)

    Kothanda Ramachandran, Dhavanesan; Kaiser, Andreas; Glasscock, Julie

    for co-extrusion and co-sintering of a porous Magnesium oxide (MgO) support with a thin film of cerium gadolinium oxide (Ce0.9Gd0.1O1.95-δ, CGO) as active oxygen transport membrane layer has been developed using a thermoplastic ceramic system and graphite as pore former. The feedstocks have been...

  5. Tailoring the microstructure of porous MgO supports for asymmetric oxygen separation membranes: Optimization of thermoplastic feedstock systems

    DEFF Research Database (Denmark)

    Kothanda Ramachandran, Dhavanesan; Clemens, F.; Glasscock, Julie

    2014-01-01

    Porous magnesium oxide (MgO) structures were prepared by thermoplastic processing for use as supports in asymmetric thin film oxygen transport membranes (OTMs). The open porosity, pore size distribution, and resulting gas permeability of the MgO structures were measured for different feedstock...

  6. Growing Up After Critical Illness: Verbal, Visual-Spatial, and Working Memory Problems in Neonatal Extracorporeal Membrane Oxygenation Survivors

    NARCIS (Netherlands)

    Madderom, M.J.; Schiller, R.M.; Gischler, S.J.; Heijst, A.F.J. van; Tibboel, D.; Aarsen, F.K.; Ijsselstijn, H.

    2016-01-01

    OBJECTIVES: To assess neuropsychologic outcome in 17- and 18-year-old neonatal extracorporeal membrane oxygenation survivors. DESIGN: A prospective longitudinal follow-up study. SETTING: Follow-up program at the Erasmus MC-Sophia Children's Hospital in Rotterdam, The Netherlands. PATIENTS: Thirty

  7. An exploratory study with an adaptive continuous intravenous furosemide regimen in neonates treated with extracorporeal membrane oxygenation

    NARCIS (Netherlands)

    M.M.J. van der Vorst (Maria); J. den Hartigh (Jan); E.D. Wildschut (Enno); D. Tibboel (Dick); J. Burggraaf (Jacobus)

    2007-01-01

    textabstractIntroduction: The objective of the present study was to explore a continuous intravenous furosemide regimen that adapts to urine output in neonates treated with extracorporeal membrane oxygenation (ECMO). Methods: Seven neonates admitted to a paediatric surgical intensive care unit for

  8. Tympanic membrane bleeding complications during hyperbaric oxygen treatment in patients with or without antiplatelet and anticoagulant drug treatment

    NARCIS (Netherlands)

    Fijen, Valerie A.; Westerweel, Peter E.; van Ooij, Pieter Jan A. M.; van Hulst, Rob A.

    2016-01-01

    Middle ear barotrauma (MEBt) is a frequently occurring complication of hyperbaric oxygen treatment (HBOT). High-grade MEBt may involve tympanic membrane (TM) haemorrhaging. Although many patients undergoing HBOT use antiplatelet or anticoagulant drugs, it is unknown whether these drugs increase the

  9. A novel approach to the management of critically ill neonatal Ebstein′s anomaly: Veno-venous extracorporeal membrane oxygenation to promote right ventricular recovery

    Directory of Open Access Journals (Sweden)

    Holly Bauser-Heaton

    2015-01-01

    Full Text Available This is the first report of the use of veno-venous extracorporeal membrane oxygenation in a neonate with severe Ebstein′s anomaly. The report suggests the use of veno-venous extracorporeal membrane oxygenation in the immediate neonatal period may be a useful therapy in severe Ebstein′s anomaly. By providing adequate oxygenation independent of the patient′s native pulmonary blood flow, veno-venous extracorporeal membrane oxygenation allows the pulmonary vascular resistance to decrease and may promote right ventricular recovery.

  10. Numerical simulation of kinetic demixing and decomposition in a LaCoO3-δ oxygen membrane under an oxygen potential gradient

    DEFF Research Database (Denmark)

    Ta, Na; Chen, Ming; Zhang, Lijun

    2018-01-01

    A composition- and temperature-dependent mobility database of all ionic species in the LaCoO3-δ phase was developed and combined with a La-Co-O thermodynamic database to simulate kinetic demixing and partial decomposition in LaCoO3-δ oxygen membranes operated under a 0.0001/0.21 bar oxygen partial...... pressure difference at 1073 K for 1 year. Formation of La2O3, Co3O4 and CoO phases across the membrane is predicted. The kinetic demixing process can be divided into two stages, namely, establishment of the oxygen potential gradient (fast) and demixing of the cations (slow); the former is controlled...... by the mobility of oxygen ions, and the latter is determined by the higher mobility of Co ions as compared to the La ion in the ABO3-type perovskite. A drift motion of both oxide surfaces towards the high PO2 side occurs with the movement of cations....

  11. Preparation and characterization of structures of oxygen-ion-conductive thin-film membranes; Herstellung und Charakterisierung von sauerstoffionenleitenden Duennschichtmembranstrukturen

    Energy Technology Data Exchange (ETDEWEB)

    Betz, Michael

    2010-07-01

    In power plants using Oxyfuel technology, fossil fuels are combusted with pure oxygen. This leads to carbon dioxide of high purity, which is necessary for its transport and storage. Oxygen separation by means of perovskitic membranes have great potential to decrease the efficiency losses caused by the allocation of the enormous amounts of oxygen. The aim of this work is the preparation and characterisation of thin film membranes on porous substrates and the analysis of their oxygen permeation properties. Therefore the material system A{sub 0,68}Sr{sub 0,3}Fe{sub 0,8}Co{sub 0,2}O{sub 3-{delta}} (A68SFC) was analysed, where the A-site was substituted with Lanthanides (La, Pr, Nd, Eu, Sm, Gd, Dy, Er) or alkaline earth metals (Ba, Ca). After an extensive characterisation, the selection was reduced to the substitutions with La, Pr and Nd. Other compounds could not meet the demands with regard to phase purity, chemical stability or extension behaviour. All analyses were conducted in comparison to Ba{sub 0,5}Sr{sub 0,5}Co{sub 0,8}Fe{sub 0,2}O{sub 3-{delta}} (BSCF) which is known to exhibit higher permeation rates, but is more sensitive to stability issues. The dependency of permeation rates on membrane thickness or oxygen partial pressures on both membrane surfaces is discussed by means of permeation measurements conducted on bulk BSCF membranes. These cannot be described completely by the Wagner equation. This is due to changes of the driving force originating from influences of the surface reaction kinetics and concentration polarisation on the membrane surface, which are not considered. Porous substrates for asymmetric membranes were manufactured by tape casting and warm pressing. The application of the functional layer was performed via screen printing. Permeation measurements show that the asymmetric structures exhibit higher permeation rates in comparison to bulk membranes with L=1 mm. The moderate increase can be attributed to the low gas permeability of the

  12. Triiodothyronine activates lactate oxidation without impairing fatty acid oxidation and improves weaning from extracorporeal membrane oxygenation.

    Science.gov (United States)

    Kajimoto, Masaki; Ledee, Dolena R; Xu, Chun; Kajimoto, Hidemi; Isern, Nancy G; Portman, Michael A

    2014-01-01

    Extracorporeal membrane oxygenation (ECMO) provides a rescue for children with severe cardiac failure. It has previously been shown that triiodothyronine (T3) improves cardiac function by modulating pyruvate oxidation during weaning. This study focused on fatty acid (FA) metabolism modulated by T3 for weaning from ECMO after cardiac injury. METHODS AND RESULTS: Nineteen immature piglets (9.1-15.3 kg) were separated into 3 groups with ECMO (6.5 h) and wean: normal circulation (Group-C); transient coronary occlusion (10 min) for ischemia-reperfusion (IR) followed by ECMO (Group-IR); and IR with T3 supplementation (Group-IR-T3). 13-Carbon ((13)C)-labeled lactate, medium-chain and long-chain FAs, was infused as oxidative substrates. Substrate fractional contribution (FC) to the citric acid cycle was analyzed by(13)C-nuclear magnetic resonance. ECMO depressed circulating T3 levels to 40% of the baseline at 4 h and were restored in Group-IR-T3. Group-IR decreased cardiac power, which was not fully restorable and 2 pigs were lost because of weaning failure. Group-IR also depressed FC-lactate, while the excellent contractile function and energy efficiency in Group-IR-T3 occurred along with a marked FC-lactate increase and [adenosine triphosphate]/[adenosine diphosphate] without either decreasing FC-FAs or elevating myocardial oxygen consumption over Group-C or -IR. T3 releases inhibition of lactate oxidation following IR injury without impairing FA oxidation. These findings indicate that T3 depression during ECMO is maladaptive, and that restoring levels improves metabolic flux and enhances contractile function during weaning.

  13. Extracorporeal membrane oxygenation in near-drowning patients with cardiac or pulmonary failure.

    Science.gov (United States)

    Kim, Kun Il; Lee, Won Yong; Kim, Hyoung Soo; Jeong, Jae Han; Ko, Ho Hyun

    2014-12-12

    The aim of this study was to determine the early outcomes of using extracorporeal membrane oxygenation (ECMO) in near-drowning patients with cardiac or pulmonary failure. This study was based on data from 9 patients including 2 children (mean age 33; 8 males, 1 female) who received ECMO after near-drowning between 2008 and 2013. Veno-arterial or veno-arteriovenous ECMO was used in 2 patients with sustained cardiac arrest and veno-venous ECMO was used in 7 patients with severe acute respiratory distress syndrome (ARDS). The means of the partial arterial oxygen pressure (PaO2), Murray score, sequential organ failure assessment (SOFA) score, and simplified acute physiology score II (SAPS-II) prior to ECMO were 59.7 ± 9.9 mmHg on 100% oxygen, 3.5 ± 0.6, 11.4 ± 1.9, and 73.0 ± 9.2, respectively. The PaO2 mean improved to 182 ± 152 mmHg within 2 h post-ECMO. The mean of SOFA score and SAPS-II decreased significantly to 8.6 ± 3.2 (p = 0.013) and 46.4 ± 5.1 (p = 0.008), respectively, at 24 h post-ECMO with mean flow rate of 3.9 ± 0.8 l/min. ECMO was weaned at a mean duration of 188 (range, 43-672) h in all patients. Seven patients were discharged home without neurological sequelae, while 2 patients who had hypoxic brain damage died after further referral. The overall survival with favourable neurological outcomes at 3 months was 77.8%. There were no complications related to ECMO. ECMO was safe and effective for patients with ongoing cardiac arrest or ARDS after a near-drowning incident and can be used as a resuscitative strategy in near-drowning patients with cardiac or pulmonary failure resistant to conventional ventilator therapy.

  14. Enhanced response of microbial fuel cell using sulfonated poly ether ether ketone membrane as a biochemical oxygen demand sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ayyaru, Sivasankaran; Dharmalingam, Sangeetha, E-mail: sangeetha@annauniv.edu

    2014-03-01

    Graphical abstract: - Highlights: • Sulfonated poly ether ether ketone (SPEEK) membrane in SCMFC used to determine the BOD. • The biosensor produces a good linear relationship with the BOD concentration up to 650 ppm. • This sensing range was 62.5% higher than that of Nafion{sup ®}. • SPEEK exhibited one order lesser oxygen permeability than Nafion{sup ®}. • Nafion{sup ®} shows high anodic internal resistance (67 Ω) than the SPEEK (39 Ω). - Abstract: The present study is focused on the development of single chamber microbial fuel cell (SCMFC) using sulfonated poly ether ether ketone (SPEEK) membrane to determine the biochemical oxygen demand (BOD) matter present in artificial wastewater (AW). The biosensor produces a good linear relationship with the BOD concentration up to 650 ppm when using artificial wastewater. This sensing range was 62.5% higher than that of Nafion{sup ®}. The most serious problem in using MFC as a BOD sensor is the oxygen diffusion into the anode compartment, which consumes electrons in the anode compartment, thereby reducing the coulomb yield and reducing the electrical signal from the MFC. SPEEK exhibited one order lesser oxygen permeability than Nafion{sup ®}, resulting in low internal resistance and substrate loss, thus improving the sensing range of BOD. The system was further improved by making a double membrane electrode assembly (MEA) with an increased electrode surface area which provide high surface area for electrically active bacteria.

  15. Mechanical Ventilation during Extracorporeal Membrane Oxygenation in Patients with Acute Severe Respiratory Failure

    Directory of Open Access Journals (Sweden)

    Zhongheng Zhang

    2017-01-01

    Full Text Available Conventionally, a substantial number of patients with acute respiratory failure require mechanical ventilation (MV to avert catastrophe of hypoxemia and hypercapnia. However, mechanical ventilation per se can cause lung injury, accelerating the disease progression. Extracorporeal membrane oxygenation (ECMO provides an alternative to rescue patients with severe respiratory failure that conventional mechanical ventilation fails to maintain adequate gas exchange. The physiology behind ECMO and its interaction with MV were reviewed. Next, we discussed the timing of ECMO initiation based on the risks and benefits of ECMO. During the running of ECMO, the protective ventilation strategy can be employed without worrying about catastrophic hypoxemia and carbon dioxide retention. There is a large body of evidence showing that protective ventilation with low tidal volume, high positive end-expiratory pressure, and prone positioning can provide benefits on mortality outcome. More recently, there is an increasing popularity on the use of awake and spontaneous breathing for patients undergoing ECMO, which is thought to be beneficial in terms of rehabilitation.

  16. Extracorporeal membrane oxygenation causes loss of intestinal epithelial barrier in the newborn piglet.

    Science.gov (United States)

    Kurundkar, Ashish R; Killingsworth, Cheryl R; McIlwain, R Britt; Timpa, Joseph G; Hartman, Yolanda E; He, Dongning; Karnatak, Rajendra K; Neel, Mary L; Clancy, John P; Anantharamaiah, G M; Maheshwari, Akhil

    2010-08-01

    Extracorporeal membrane oxygenation (ECMO) is an important life-support system used in neonates and young children with intractable cardiorespiratory failure. In this study, we used our porcine neonatal model of venoarterial ECMO to investigate whether ECMO causes gut barrier dysfunction. We subjected 3-wk-old previously healthy piglets to venoarterial ECMO for up to 8 h and evaluated gut mucosal permeability, bacterial translocation, plasma levels of bacterial products, and ultrastructural changes in gut epithelium. We also measured plasma lipopolysaccharide (LPS) levels in a small cohort of human neonates receiving ECMO. In our porcine model, ECMO caused a rapid increase in gut mucosal permeability within the first 2 h of treatment, leading to a 6- to 10-fold rise in circulating bacterial products. These changes in barrier function were associated with cytoskeletal condensation in epithelial cells, which was explained by phosphorylation of a myosin II regulatory light chain. In support of these findings, we also detected elevated plasma LPS levels in human neonates receiving ECMO, indicating a similar loss of gut barrier function in these infants. On the basis of these data, we conclude that ECMO is an independent cause of gut barrier dysfunction and bacterial translocation may be an important contributor to ECMO-related inflammation.

  17. Mechanical Ventilation during Extracorporeal Membrane Oxygenation in Patients with Acute Severe Respiratory Failure.

    Science.gov (United States)

    Zhang, Zhongheng; Gu, Wan-Jie; Chen, Kun; Ni, Hongying

    2017-01-01

    Conventionally, a substantial number of patients with acute respiratory failure require mechanical ventilation (MV) to avert catastrophe of hypoxemia and hypercapnia. However, mechanical ventilation per se can cause lung injury, accelerating the disease progression. Extracorporeal membrane oxygenation (ECMO) provides an alternative to rescue patients with severe respiratory failure that conventional mechanical ventilation fails to maintain adequate gas exchange. The physiology behind ECMO and its interaction with MV were reviewed. Next, we discussed the timing of ECMO initiation based on the risks and benefits of ECMO. During the running of ECMO, the protective ventilation strategy can be employed without worrying about catastrophic hypoxemia and carbon dioxide retention. There is a large body of evidence showing that protective ventilation with low tidal volume, high positive end-expiratory pressure, and prone positioning can provide benefits on mortality outcome. More recently, there is an increasing popularity on the use of awake and spontaneous breathing for patients undergoing ECMO, which is thought to be beneficial in terms of rehabilitation.

  18. Alveolar and serum concentrations of imipenem in two lung transplant recipients supported with extracorporeal membrane oxygenation.

    Science.gov (United States)

    Welsch, C; Augustin, P; Allyn, J; Massias, L; Montravers, P; Allou, N

    2015-02-01

    Venovenous extracorporeal membrane oxygenation (ECMO) is increasingly used in patients with respiratory failure who fail conventional treatment. Postoperative pneumonia is the most common infection after lung transplantation (40%). Imipenem is frequently used for empirical treatment of nosocomial pneumonia in the intensive care unit. Nevertheless, few data are available on the impact of ECMO on pharmacokinetics, and no data on imipenem dosing during ECMO. Currently, no guidelines exist for antibiotic dosing during ECMO support. We report the cases of 2 patients supported with venovenous ECMO for refractory acute respiratory distress syndrome following single lung transplantation for pulmonary fibrosis, treated empirically with 1 g of imipenem intravenously every 6 h. Enterobacter cloacae was isolated from the respiratory sample of Patient 1 and Klebsiella pneumoniae was isolated from the respiratory sample of Patient 2. Minimum inhibitory concentrations of the 2 isolated strains were 0.125 and 0.25 mg/L, respectively. Both patients were still alive on day 28. This is the first report, to our knowledge, of imipenem concentrations in lung transplantation patients supported with ECMO. This study confirms high variability in imipenem trough concentrations in patients on ECMO and with preserved renal function. An elevated dosing regimen (4 g/24 h) is more likely to optimize drug exposure, and therapeutic drug monitoring is recommended, where available. Population pharmacokinetic studies are indicated to develop evidence-based dosing guidelines for ECMO patients. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Roller and Centrifugal Pumps: A Retrospective Comparison of Bleeding Complications in Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Halaweish, Ihab; Cole, Adam; Cooley, Elaine; Lynch, William R; Haft, Jonathan W

    2015-01-01

    Centrifugal pumps are increasingly used for extracorporeal membrane oxygenation (ECMO) rather than roller pumps. However, shear forces induced by these types of continuousflow pumps are associated with acquired von Willebrand factor deficiency and bleeding complications. This study was undertaken to compare adverse bleeding complications with the use of centrifugal and roller pumps in patients on prolonged ECMO support. The records of all adult ECMO patients from June 2002 to 2013 were retrospectively reviewed using the University of Michigan Health System database and the Extracorporeal Life Support Organization registry, focusing on patients supported for at least 5 days. Ninety-five ECMO patients met criteria for inclusion (48 roller vs. 47 centrifugal pump). Indications included pulmonary (79%), cardiac (15%), and extracorporeal cardiopulmonary resuscitation (6%), without significant difference between the two groups. Despite lower heparin anticoagulation (10.9 vs. 13.7 IU/kg/hr) with centrifugal pumps, there was a higher incidence of nonsurgical bleeding (gastrointestinal, pulmonary, and neurological) in centrifugal pump patients (26.1 vs. 9.0 events/1,000 patient-days, p = 0.024). In conclusion, in our historical comparison, despite reduced anticoagulation, ECMO support using centrifugal pumps was associated with a higher incidence of nonsurgical bleeding. The mechanisms behind this are multifactorial and require further investigation.

  20. The neutrophil to lymphocyte ratio in patients supported with extracorporeal membrane oxygenation.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Pappas, Patroklos; Tatooles, Antone

    2018-04-01

    The neutrophil to lymphocyte ratio (NLR) has proven to be a robust predictor of mortality in a wide range of cardiovascular diseases. This study investigated the predictive value of the NLR in patients supported by extracorporeal membrane oxygenation (ECMO) systems. This study included 107 patients who underwent ECMO implantation for cardiogenic shock. Median preoperative NLR was used to divide the cohort, with Group 1 NLR <14.2 and Group 2 with NLR ≥14.2. Survival, the primary outcome, was compared between groups. The study cohort was composed of 64 (60%) males with an average age 53.1 ± 14.9 years. Patients in Group 1 had an average NLR of 7.5 ± 3.5 compared to 27.1 ± 19.9 in Group 2. Additionally, those in Group 2 had significantly higher preoperative blood urea nitrogen (BUN) and age. Survival analysis indicated a thirty-day survival of 56.2%, with significantly worsened mortality in patients with NLR greater than 14.2, p=0.047. Our study shows the NLR has prognostic value in patients undergoing ECMO implantation. Leukocytes are known contributors to myocardial damage and neutrophil infiltration is associated with damage caused by myocardial ischemia.

  1. Rapid resolution of hyperammonemia in neonates using extracorporeal membrane oxygenation as a platform to drive hemodialysis.

    Science.gov (United States)

    Robinson, Jamie R; Conroy, Patricia C; Hardison, Daphne; Hamid, Rizwan; Grubb, Peter H; Pietsch, John B; Lovvorn, Harold N

    2018-02-21

    We aimed to clarify the impact of extracorporeal membrane oxygenation (ECMO) as a platform to drive hemodialysis (HD) for ammonia clearance on outcomes of neonates with severe hyperammonemia. All neonates treated for hyperammonemia at a single children's hospital between 1992 and 2016 were identified. Patient characteristics and outcomes were compared between those receiving medical management or ECMO/HD. Twenty-five neonates were treated for hyperammonemia, of which 13 (52%) received ECMO/HD. Peak ammonia levels among neonates treated with ECMO/HD were significantly higher than those medically managed (1041 [IQR 902-1581] μmol/L versus 212 [IQR 110-410] μmol/L; p = 0.009). Serum ammonia levels in the ECMO/HD cohort declined to the median of medically managed within 4.5 (IQR 2.9-7.0) hours and normalized within 7.3 (IQR 3.6-13.5) hours. All neonates survived ECMO/HD, and nine (69.2%) survived to discharge. ECMO/HD is an effective adjunct to rapidly clear severe hyperammonemia in newborns, reducing potential neurodevelopmental morbidity.

  2. Triiodothyronine facilitates weaning from extracorporeal membrane oxygenation by improved mitochondrial substrate utilization.

    Science.gov (United States)

    Files, Matthew D; Kajimoto, Masaki; O'Kelly Priddy, Colleen M; Ledee, Dolena R; Xu, Chun; Des Rosiers, Christine; Isern, Nancy; Portman, Michael A

    2014-03-20

    Extracorporeal membrane oxygenation (ECMO) provides a bridge to recovery after myocardial injury in infants and children, yet morbidity and mortality remain high. Weaning from the circuit requires adequate cardiac contractile function, which can be impaired by metabolic disturbances induced either by ischemia-reperfusion and/or by ECMO. We tested the hypothesis that although ECMO partially ameliorates metabolic abnormalities induced by ischemia-reperfusion, these abnormalities persist or recur with weaning. We also determined if thyroid hormone supplementation (triiodothyronine) during ECMO improves oxidative metabolism and cardiac function. Neonatal piglets underwent transient coronary ischemia to induce cardiac injury then were separated into 4 groups based on loading status. Piglets without coronary ischemia served as controls. We infused into the left coronary artery [2-(13)C]pyruvate and [(13)C6, (15)N]l-leucine to evaluate oxidative metabolism by gas chromatography-mass spectroscopy and nuclear magnetic resonance methods. ECMO improved survival, increased oxidative substrate contribution through pyruvate dehydrogenase, reduced succinate and fumarate accumulation, and ameliorated ATP depletion induced by ischemia. The functional and metabolic benefit of ECMO was lost with weaning, yet triiodothyronine supplementation during ECMO restored function, increased relative pyruvate dehydrogenase flux, reduced succinate and fumarate, and preserved ATP stores. Although ECMO provides metabolic rest by decreasing energy demand, metabolic impairments persist, and are exacerbated with weaning. Treating ECMO-induced thyroid depression with triiodothyronine improves substrate flux, myocardial oxidative capacity and cardiac contractile function. This translational model suggests that metabolic targeting can improve weaning.

  3. Long-term neurodevelopmental outcomes of congenital diaphragmatic hernia survivors not treated with extracorporeal membrane oxygenation.

    Science.gov (United States)

    Frisk, Virginia; Jakobson, Lorna S; Unger, Sharon; Trachsel, Daniel; O'Brien, Karel

    2011-07-01

    Although there has been a marked improvement in the survival of children with congenital diaphragmatic hernia (CDH) in the past 2 decades, there are few reports of long-term neurodevelopmental outcome in this population. The present study examined neurodevelopmental outcomes in 10- to 16-year-old CDH survivors not treated with extracorporeal membrane oxygenation (ECMO). Parents of 27 CDH survivors completed questionnaires assessing medical problems, daily living skills, educational outcomes, behavioral problems, and executive functioning. Fifteen CDH survivors and matched full-term controls completed standardized intelligence, academic achievement, phonological processing, and working memory tests. Non-ECMO-treated CDH survivors demonstrated high rates of clinically significant difficulties on standardized academic achievement measures, and 14 of the 27 survivors had a formal diagnosis of specific learning disability, attention deficit hyperactivity disorder, or developmental disability. Specific problems with executive function, cognitive and attentional weaknesses, and social difficulties were more common in CDH patients than controls. Perioperative hypocapnia was linked to executive dysfunction, behavioral problems, lowered intelligence, and poor achievement in mathematics. Non-ECMO-treated CDH survivors are at substantial risk for neurodevelopmental problems in late childhood and adolescence. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Emerging indications for extracorporeal membrane oxygenation in adults with respiratory failure.

    Science.gov (United States)

    Abrams, Darryl; Brodie, Daniel

    2013-08-01

    Recent advances in technology have spurred the increasing use of extracorporeal membrane oxygenation (ECMO) in patients with severe hypoxemic respiratory failure. However, this accounts for only a small percentage of patients with respiratory failure. We envision the application of ECMO in many other forms of respiratory failure in the coming years. Patients with less severe forms of acute respiratory distress syndrome, for instance, may benefit from enhanced lung-protective ventilation with the very low tidal volumes made possible by direct carbon dioxide removal from the blood. For those in whom hypercapnia predominates, extracorporeal support will allow for the elimination of invasive mechanical ventilation in some cases. The potential benefits of ECMO may be further enhanced by improved techniques, which facilitate active mobilization. Although ECMO for these and other expanded applications is under active investigation, it has yet to be proven beneficial in these settings in rigorous controlled trials. Ultimately, with upcoming and future technological advances, there is the promise of true destination therapy, which could lead to a major paradigm shift in the management of respiratory failure.

  5. The Complex Relationship of Extracorporeal Membrane Oxygenation and Acute Kidney Injury: Causation or Association?

    Science.gov (United States)

    Kilburn, Daniel J; Shekar, Kiran; Fraser, John F

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) is a modified cardiopulmonary bypass (CPB) circuit capable of providing prolonged cardiorespiratory support. Recent advancement in ECMO technology has resulted in increased utilisation and clinical application. It can be used as a bridge-to-recovery, bridge-to-bridge, bridge-to-transplant, or bridge-to-decision. ECMO can restitute physiology in critically ill patients, which may minimise the risk of progressive multiorgan dysfunction. Alternatively, iatrogenic complications of ECMO clearly contribute to worse outcomes. These factors affect the risk : benefit ratio of ECMO which ultimately influence commencement/timing of ECMO. The complex interplay of pre-ECMO, ECMO, and post-ECMO pathophysiological processes are responsible for the substantial increased incidence of ECMO-associated acute kidney injury (EAKI). The development of EAKI significantly contributes to morbidity and mortality; however, there is a lack of evidence defining a potential benefit or causative link between ECMO and AKI. This area warrants investigation as further research will delineate the mechanisms involved and subsequent strategies to minimise the risk of EAKI. This review summarizes the current literature of ECMO and AKI, considers the possible benefits and risks of ECMO on renal function, outlines the related pathophysiology, highlights relevant investigative tools, and ultimately suggests an approach for future research into this under investigated area of critical care.

  6. The Complex Relationship of Extracorporeal Membrane Oxygenation and Acute Kidney Injury: Causation or Association?

    Directory of Open Access Journals (Sweden)

    Daniel J. Kilburn

    2016-01-01

    Full Text Available Extracorporeal membrane oxygenation (ECMO is a modified cardiopulmonary bypass (CPB circuit capable of providing prolonged cardiorespiratory support. Recent advancement in ECMO technology has resulted in increased utilisation and clinical application. It can be used as a bridge-to-recovery, bridge-to-bridge, bridge-to-transplant, or bridge-to-decision. ECMO can restitute physiology in critically ill patients, which may minimise the risk of progressive multiorgan dysfunction. Alternatively, iatrogenic complications of ECMO clearly contribute to worse outcomes. These factors affect the risk : benefit ratio of ECMO which ultimately influence commencement/timing of ECMO. The complex interplay of pre-ECMO, ECMO, and post-ECMO pathophysiological processes are responsible for the substantial increased incidence of ECMO-associated acute kidney injury (EAKI. The development of EAKI significantly contributes to morbidity and mortality; however, there is a lack of evidence defining a potential benefit or causative link between ECMO and AKI. This area warrants investigation as further research will delineate the mechanisms involved and subsequent strategies to minimise the risk of EAKI. This review summarizes the current literature of ECMO and AKI, considers the possible benefits and risks of ECMO on renal function, outlines the related pathophysiology, highlights relevant investigative tools, and ultimately suggests an approach for future research into this under investigated area of critical care.

  7. The Evaluation of Nosocomial Infections in Pediatric Patients with Extracorporeal Membrane Oxygenation Support

    Directory of Open Access Journals (Sweden)

    Pelin Ayyıldız

    Full Text Available Abstract Introduction: Extracorporeal membrane oxygenation (ECMO has become a standard technique over the past few decades in intensive care unit (ICU. Objective: A review of pediatric patients who received ECMO support in the pediatric cardiac ICU was conducted to determine the incidence, risk factors and causal organisms related to acquired infections and assess the survival rates of ECMO patients with nosocomial infections. Methods: Sixty-six patients who received ECMO support in the pediatric cardiac ICU between January 2011 and June 2014 were included in the study. Demographic, echocardiographic, hemodynamic features and surgical procedures were reviewed. Results: Sixty-six patients received a total of 292.5 days of venoarterial ECMO support. Sixty were postoperative patients. Forty-five patients were weaned from ECMO support with an ECMO survival rate of 68.2%. The rate of infection was 116.2/1000 ECMO days. Prolonged ICU stay, duration of ventilation and ECMO were found associated with development of nosocomial infection and only the duration of ECMO was an independent risk factor for nosocomial infections in ECMO patients. Conclusion: The correction of the underlying process leading to ECMO support and shortening the length of ECMO duration together with stricter application of ECMO indications would improve the infection incidence and hospital surveillance of the patient group.

  8. Hemocompatibility and oxygenation performance of polysulfone membranes grafted with polyethylene glycol and heparin by plasma-induced surface modification.

    Science.gov (United States)

    Wang, Weiping; Zheng, Zhi; Huang, Xin; Fan, Wenling; Yu, Wenkui; Zhang, Zhibing; Li, Lei; Mao, Chun

    2017-10-01

    Polyethylene glycol (PEG) and heparin (Hep) were grafted onto polysulfone (PSF) membrane by plasma-induced surface modification to prepare PSF-PEG-Hep membranes used for artificial lung. The effects of plasma treatment parameters, including power, gas type, gas flow rate, and treatment time, were investigated, and different PEG chains were bonded covalently onto the surface in the postplasma grafting process. Membrane surfaces were characterized by water contact angle, PEG grafting degree, attenuated total reflectance-Fourier transform infrared spectroscopy, ultraviolet-visible spectrophotometry, X-ray photoelectron spectroscopy, critical water permeability pressure, and scanning electron microscopy. Protein adsorption, platelet adhesion, and coagulation tests showed significant improvement in the hemocompatibility of PSF-PEG-Hep membranes compared to pristine PSF membrane. Gas exchange tests through PSF-PEG6000-Hep membrane showed that when the flow rate of porcine blood reached 5.0 L/min, the permeation fluxes of O 2 and CO 2 reached 192.6 and 166.9 mL/min, respectively, which were close to the gas exchange capacity of a commercial membrane oxygenator. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1737-1746, 2017. © 2016 Wiley Periodicals, Inc.

  9. [Impact of oxygen toxic action on the erythrocyte membrane and possibility of estimating central nervous system function disturbances].

    Science.gov (United States)

    Belić, Branislava; Cincović, Marko R

    2011-07-01

    BACKGROUND/AIM; Prolonged exposure to hyperbaric oxygen leads to changes of erythrocytes shape as a consequence of toxic effects of oxygen on the erythrocyte membrane. The aim of this study was to examine the association between occurance of pathological forms of erythrocytes at different time from the start of hyperbaric oxygenation and the moment of convulsions occurrence, an interrelationship of different pathological forms of erythrocytes during exposure to hyperbaric oxygenation, as well as the correlation between the presence of ruptured erythrocytes and function of central nervous system (CNS) after completion of hyperbaric treatment. Sixty laboratory mice, Mus musculus, were exposed to the wholly-oxygen pressure of 3.5 absolute atmospheres (ATA). Blood was collected at the 32nd, 34th, 36th, 38th and 40th minutes after the exposure to oxygen. Pathological forms of erythrocytes were examined by electron microscopy. A moment of convulsions occurrence was registered in all animals. After decompression neurological examinations of experimental animals were perfomed. The Pearson's coefficient of correlation, and linear regression equations for the parameters outlined in the aim of the study were calculated. Hyperbaric oxygen caused damages of erythrocytes at the 34th minute after beginning of the treatment. Various forms of abnormal red blood cells occured, and immediately before the occurrence of irreversible changes (erythrocyte membrane rupture) echinocyte shape was dominated. A significant correlation between the number of damaged red blood cells at 34th minute and their number at the 36th, 38th and 40th minute was found. Convulsions were diagnosed significantly earlier in mice with a greater number of damaged red blood cells (p potential burden of CNS after cessation of hyperbaric oxygenation.

  10. Fabrication and performance of a tubular ceria based oxygen transport membrane on a low cost MgO support

    DEFF Research Database (Denmark)

    Kothanda Ramachandran, Dhavanesan; Søgaard, Martin; Clemens, F.

    2015-01-01

    A 30 μm thin-film tubular CGO (Ce0.9Gd0.1O1.95−δ) membrane with catalytic layers on both sides has been prepared by dip-coating on a low cost, porous magnesium oxide (MgO) support. The MgO support was fabricated through a thermoplastic extrusion process. Support, thin membrane and catalytic layer...... atmospheric air and N2, H2 for the feed and sweep side respectively. The oxygen permeation was 4 N ml min−1 cm−2 at 850 °C using H2 on one side and air on the other side....

  11. Arabidopsis dynamin-related protein 1E in sphingolipid-enriched plasma membrane domains is associated with the development of freezing tolerance.

    Science.gov (United States)

    Minami, Anzu; Tominaga, Yoko; Furuto, Akari; Kondo, Mariko; Kawamura, Yukio; Uemura, Matsuo

    2015-08-01

    The freezing tolerance of Arabidopsis thaliana is enhanced by cold acclimation, resulting in changes in the compositions and function of the plasma membrane. Here, we show that a dynamin-related protein 1E (DRP1E), which is thought to function in the vesicle trafficking pathway in cells, is related to an increase in freezing tolerance during cold acclimation. DRP1E accumulated in sphingolipid and sterol-enriched plasma membrane domains after cold acclimation. Analysis of drp1e mutants clearly showed that DRP1E is required for full development of freezing tolerance after cold acclimation. DRP1E fused with green fluorescent protein was visible as small foci that overlapped with fluorescent dye-labelled plasma membrane, providing evidence that DRP1E localizes non-uniformly in specific areas of the plasma membrane. These results suggest that DRP1E accumulates in sphingolipid and sterol-enriched plasma membrane domains and plays a role in freezing tolerance development during cold acclimation. © 2015 The Authors The Plant Journal © 2015 John Wiley & Sons Ltd.

  12. High-throughput simultaneous determination of plasma water deuterium and 18-oxygen enrichment using a high-temperature conversion elemental analyzer with isotope ratio mass spectrometry.

    Science.gov (United States)

    Richelle, M; Darimont, C; Piguet-Welsch, C; Fay, L B

    2004-01-01

    This paper presents a high-throughput method for the simultaneous determination of deuterium and oxygen-18 (18O) enrichment of water samples isolated from blood. This analytical method enables rapid and simple determination of these enrichments of microgram quantities of water. Water is converted into hydrogen and carbon monoxide gases by the use of a high-temperature conversion elemental analyzer (TC-EA), that are then transferred on-line into the isotope ratio mass spectrometer. Accuracy determined with the standard light Antartic precipitation (SLAP) and Greenland ice sheet precipitation (GISP) is reliable for deuterium and 18O enrichments. The range of linearity is from 0 up to 0.09 atom percent excess (APE, i.e. -78 up to 5725 delta per mil (dpm)) for deuterium enrichment and from 0 up to 0.17 APE (-11 up to 890 dpm) for 18O enrichment. Memory effects do exist but can be avoided by analyzing the biological samples in quintuplet. This method allows the determination of 1440 samples per week, i.e. 288 biological samples per week. Copyright 2004 John Wiley & Sons, Ltd.

  13. Acute kidney injury and renal replacement therapy independently predict mortality in neonatal and pediatric noncardiac patients on extracorporeal membrane oxygenation.

    Science.gov (United States)

    Askenazi, David J; Ambalavanan, Namasivayam; Hamilton, Kiya; Cutter, Gary; Laney, Debbie; Kaslow, Richard; Georgeson, Keith; Barnhart, Douglas C; Dimmitt, Reed A

    2011-01-01

    To determine the independent impact of acute kidney injury (AKI) and renal replacement therapy (RRT) in infants and children who receive extracorporeal membrane oxygenation. Despite continued expertise/technological advancement, patients who receive extracorporeal membrane oxygenation have high mortality. AKI and RRT portend poor outcomes independent of comorbidities and illness severity in several critically ill populations. Retrospective cohort study. The primary variables explored are AKI (categorical complication code for serum creatinine > 1.5 mg/dL or International Statistical Classification of Diseases and Related Health Problems, Revision 9 for acute renal failure), and RRT (complication/Current Procedural Terminology code for dialysis or hemofiltration). Multiple variables previously associated with mortality in this population were controlled, using logistic stepwise regression. Decision tree modeling was performed to determine optimal variables and cut points to predict mortality. Critically ill neonates (0-30 days old) and children (> 30 days but optimizing the timing/delivery of RRT may positively impact survival.

  14. Lipid engineering reveals regulatory roles for membrane fluidity in yeast flocculation and oxygen-limited growth

    DEFF Research Database (Denmark)

    Degreif, Daniel; de Rond, Tristan; Bertl, Adam

    2017-01-01

    Cells modulate lipid metabolism in order to maintain membrane homeostasis. Here we use a metabolic engineering approach to manipulate the stoichiometry of fatty acid unsaturation, a regulator of cell membrane fluidity, in Saccharomyces cerevisiae. Unexpectedly, reduced lipid unsaturation triggere...

  15. U enrichment and Th/U fractionation in Archean boninites: Implications for paleo-ocean oxygenation and U cycling at juvenile subduction zones

    Science.gov (United States)

    Manikyamba, C.; Said, Nuru; Santosh, M.; Saha, Abhishek; Ganguly, Sohini; Subramanyam, K. S. V.

    2018-05-01

    Phanerozoic boninites record enrichments of U over Th, giving Th/U: 0.5-1.6, relative to intraoceanic island arc tholeiites (IAT) where Th/U averages 2.6. Uranium enrichment is attributed to incorporation of shallow, oxidized fluids, U-rich but Th-poor, from the slab into the melt column of boninites which form in near-trench to forearc settings of suprasubduction zone ophiolites. Well preserved Archean komatiite-tholeiite, plume-derived, oceanic volcanic sequences have primary magmatic Th/U ratios of 4.4-3.6, and Archean convergent margin IAT volcanic sequences, having REE and HFSE compositions similar to Phanerozoic IAT equivalents, preserve primary Th/U of 4-3.6. The best preserved Archean boninites of the 3.0 Ga Olondo and 2.7 Ga Gadwal greenstone belts, hosted in convergent margin ophiolite sequences, also show relative enrichments of U over Th, with low average Th/U ∼3 relative to coeval IAT, and Phanerozoic counterparts which are devoid of crustal contamination and therefore erupted in an intraoceanic setting, with minimal contemporaneous submarine hydrothermal alteration. Later enrichment of U is unlikely as Th-U-Nb-LREE patterns are coherent in these boninites whereas secondary effects induce dispersion of Th/U ratios. The variation in Th/U ratios from Archean to Phanerozoic boninites of greenstone belts to ophiolitic sequences reflect on genesis of boninitic lavas at different tectono-thermal regimes. Consequently, if the explanation for U enrichment in Phanerozoic boninites also applies to Archean examples, the implication is that U was soluble in oxygenated Archean marine water up to 600 Ma before the proposed great oxygenation event (GOE) at ∼2.4 Ga. This interpretation is consistent with large Ce anomalies in some hydrothermally altered Archean volcanic sequences aged 3.0-2.7 Ga.

  16. Cerebral and lower limb near-infrared spectroscopy in adults on extracorporeal membrane oxygenation.

    Science.gov (United States)

    Wong, Joshua K; Smith, Thomas N; Pitcher, Harrison T; Hirose, Hitoshi; Cavarocchi, Nicholas C

    2012-08-01

    Percutaneous femoral venoarterial (VA) or jugular venovenous (VV) extracorporeal membrane oxygenation (ECMO) can result in delivery of hypoxic blood to the brain, coronaries, and upper extremities. Additionally, VA-ECMO by percutaneous femoral artery cannulation may compromise perfusion to the lower limbs. Use of near-infrared spectroscopy (NIRS) detects regional ischemia and warns of impending hypoxic damage. We report the first known series with standardized monitoring of this parameter in adults on ECMO. This is an institutional review board-approved single institution retrospective review of patients with NIRS monitoring on ECMO from July 2010 until June 2011. Patients were analyzed for drops in NIRS tracings below 40 or >25% from baseline. VA-ECMO and VV-ECMO were initiated by percutaneous cannulation of the femoral vessels and the internal jugular vein, respectively. Sensors were placed on the patients' foreheads and on the lower limbs. NIRS tracings were recorded, analyzed, and correlated with clinical events. Twenty patients were analyzed (median age: 47.5 years): 17 patients were placed on VA-ECMO, and three patients on VV-ECMO. The median duration on ECMO was 7 days (range 2-26). One hundred percent of patients had a significant drop in bilateral cerebral oximetry tracings resulting in hemodynamic interventions, which involved increasing pressure, oxygenation, and/or ECMO flow. In 16 patients (80%), these interventions corrected the underlying ischemia. Four patients (20%) required further diagnostic intervention for persistent decreased bilateral and/or unilateral cerebral oximetry tracings, and were found to have a cerebrovascular accident (CVA). Six (30%) patients had persistent unilateral lower limb oximetry events, which resolved upon placement or replacement of a distal perfusion cannula. No patient was found to have either lower limb ischemia or a CVA with normal NIRS tracings. Use of NIRS with ECMO is important in detecting ischemic cerebral and

  17. Extracorporeal membrane oxygenation as a bridge to lung transplantation: A single-center experience in the present era.

    Science.gov (United States)

    Todd, Emily M; Biswas Roy, Sreeja; Hashimi, A Samad; Serrone, Rosemarie; Panchanathan, Roshan; Kang, Paul; Varsch, Katherine E; Steinbock, Barry E; Huang, Jasmine; Omar, Ashraf; Patel, Vipul; Walia, Rajat; Smith, Michael A; Bremner, Ross M

    2017-11-01

    Extracorporeal membrane oxygenation has been used as a bridge to lung transplantation in patients with rapid pulmonary function deterioration. The reported success of this modality and perioperative and functional outcomes are varied. We retrospectively reviewed all patients who underwent lung transplantation at our institution over 1 year (January 1, 2015, to December 31, 2015). Patients were divided into 2 groups depending on whether they required extracorporeal membrane oxygenation support as a bridge to transplant; preoperative characteristics, lung transplantation outcomes, and survival were compared between groups. Of the 93 patients, 12 (13%) received bridge to transplant, and 81 (87%) did not. Patients receiving bridge to transplant were younger, had higher lung allocation scores, had lower functional status, and were more often on mechanical ventilation at listing. Most patients who received bridge to transplant (n = 10, 83.3%) had pulmonary fibrosis. Mean pretransplant extracorporeal membrane oxygenation support was 103.6 hours in duration (range, 16-395 hours). All patients who received bridge to transplant were decannulated immediately after lung transplantation but were more likely to return to the operating room for secondary chest closure or rethoracotomy. Grade 3 primary graft dysfunction within 72 hours was similar between groups. Lung transplantation success and hospital discharge were 100% in the bridge to transplant group; however, these patients experienced longer hospital stays and higher rates of discharge to acute rehabilitation. The 1-year survival was 100% in the bridge to transplant group and 91% in the non-bridge to transplant group (log-rank, P = .24). The 1-year functional status was excellent in both groups. Extracorporeal membrane oxygenation can be used to safely bridge high-acuity patients with end-stage lung disease to lung transplantation with good 30-day, 90-day, and 1-year survival and excellent 1-year functional status

  18. Graphite and PMMA as pore formers for thermoplastic extrusion of porous 3Y-TZP oxygen transport membrane supports

    DEFF Research Database (Denmark)

    Bjørnetun Haugen, Astri; Gurauskis, Jonas; Kaiser, Andreas

    2016-01-01

    A gas permeable porous support is a crucial part of an asymmetric oxygen transport membrane (OTM). Here, we develop feedstocks for thermoplastic extrusion of tubular, porous 3Y-TZP (partially stabilized zirconia polycrystals, (Y2O3)0.03(ZrO2)0.97)) ceramics, using graphite and/or polymethyl....... This demonstrates the suitability of thermoplastic extrusion for fabrication of porous 3Y-TZP OTM supports, or for other technologies requiring porous ceramics....

  19. Chronic mould exposure as a risk factor for severe community acquired pneumonia in a patient requiring extra corporeal membrane oxygenation

    Directory of Open Access Journals (Sweden)

    Stephanie Thomas

    2015-01-01

    Full Text Available A previously fit and well man developed acute respiratory failure due to environmental mould exposure from living in damp rental accommodation. Despite aggressive intensive care management he rapidly deteriorated and required respiratory and cardiac Extracorporeal Membrane Oxygenation. We hypothesize that poor domiciliary conditions may make an underestimated contribution to community respiratory disease. These conditions may present as acute and severe illness with non-typical pathogens identified.

  20. Scaling laws for oxygen transport across the space-filling system of respiratory membranes in the human lung

    Science.gov (United States)

    Hou, Chen

    Space-filling fractal surfaces play a fundamental role in how organisms function at various levels and in how structure determines function at different levels. In this thesis, we develop a quantitative theory of oxygen transport to and across the surface of the highly branched, space-filling system of alveoli, the fundamental gas exchange unit (acinar airways), in the human lung. Oxygen transport in the acinar airways is by diffusion, and we treat the two steps---diffusion through the branched airways, and transfer across the alveolar membranes---as a stationary diffusion-reaction problem, taking into account that there may be steep concentration gradients between the entrance and remote alveoli (screening). We develop a renormalization treatment of this screening effect and derive an analytic formula for the oxygen current across the cumulative alveolar membrane surface, modeled as a fractal, space-filling surface. The formula predicts the current from a minimum of morphological data of the acinus and appropriate values of the transport parameters, through a number of power laws (scaling laws). We find that the lung at rest operates near the borderline between partial screening and no screening; that it switches to no screening under exercise; and that the computed currents agree with measured values within experimental uncertainties. From an analysis of the computed current as a function of membrane permeability, we find that the space-filling structure of the gas exchanger is simultaneously optimal with respect to five criteria. The exchanger (i) generates a maximum oxygen current at minimum permeability; (ii) 'wastes' a minimum of surface area; (iii) maintains a minimum residence time of oxygen in the acinar airways; (iv) has a maximum fault tolerance to loss of permeability; and (v) generates a maximum current increase when switching from rest to exercise.

  1. Point-of-Care Ultrasound-Guided Percutaneous Cannulation of Extracorporeal Membrane Oxygenation: Make it Simple.

    Science.gov (United States)

    Ahn, Hong Joon; Lee, Jun Wan; Joo, Ki Hyuk; You, Yeon Ho; Ryu, Seung; Lee, Jin Woong; Kim, Seung Whan

    2017-12-30

    Cannulation of the great vessels is required for extracorporeal membrane oxygenation (ECMO). Currently, there is no guideline for optimal imaging modalities during percutaneous cannulation of ECMO. The purpose of this study was to describe percutaneous cannulation guided by point-of-care ultrasound (POCUS) for ECMO and compare it with fluoroscopy and landmark guidance. Three groups (POCUS-, fluoroscopy-, and landmark-guided) of percutaneous cannulation for ECMO were analyzed retrospectively in a tertiary academic hospital. In the POCUS-guided group, visual confirmation of guidewire and cannula by ultrasound in both the access and return cannula were essential for successful cannulation. Fluoroscopy- and landmark-guided groups were cannulated with the conventional technique. A total of 128 patients were treated by ECMO during the study period, of which 94 (73.4%) cases were venoarterial ECMO. This included 56 cases of extracorporeal cardiopulmonary resuscitation. Also, there were 30 (23.4%) cases of venovenous ECMO and 4 (3.1%) cases of venoarteriovenous ECMO. A total of 71 (55.5%) patients were cannulated under POCUS guidance, and 43 (33.6%) patients were cannulated under fluoroscopy guidance and 14 (10.9%) patients were cannulated by landmark guidance. No surgical cut downs were required. Misplacement of cannula occurred in 3 (2.3%) cases. All three occurred in the landmark-guided group. POCUS-guided cannulation is comparable to fluoroscopy-guided cannulation in terms of avoiding cannula misplacement. In our experience, POCUS-guided cannulation is a useful strategy over fluoroscopy- and landmark-guided cannulation during peripheral ECMO. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Factors Associated with Bleeding and Thrombosis in Children Receiving Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Dalton, Heidi J; Reeder, Ron; Garcia-Filion, Pamela; Holubkov, Richard; Berg, Robert A; Zuppa, Athena; Moler, Frank W; Shanley, Thomas; Pollack, Murray M; Newth, Christopher; Berger, John; Wessel, David; Carcillo, Joseph; Bell, Michael; Heidemann, Sabrina; Meert, Kathleen L; Harrison, Richard; Doctor, Allan; Tamburro, Robert F; Dean, J Michael; Jenkins, Tammara; Nicholson, Carol

    2017-09-15

    Extracorporeal membrane oxygenation (ECMO) is used for respiratory and cardiac failure in children but is complicated by bleeding and thrombosis. (1) To measure the incidence of bleeding (blood loss requiring transfusion or intracranial hemorrhage) and thrombosis during ECMO support; (2) to identify factors associated with these complications; and (3) to determine the impact of these complications on patient outcome. This was a prospective, observational cohort study in pediatric, cardiac, and neonatal intensive care units in eight hospitals, carried out from December 2012 to September 2014. ECMO was used on 514 consecutive patients under age 19 years. Demographics, anticoagulation practices, severity of illness, circuitry components, bleeding, thrombotic events, and outcome were recorded. Survival was 54.9%. Bleeding occurred in 70.2%, including intracranial hemorrhage in 16%, and was independently associated with higher daily risk of mortality. Circuit component changes were required in 31.1%, and patient-related clots occurred in 12.8%. Laboratory sampling contributed to transfusion requirement in 56.6%, and was the sole reason for at least one transfusion in 42.2% of patients. Pump type was not associated with bleeding, thrombosis, hemolysis, or mortality. Hemolysis was predictive of subsequent thrombotic events. Neither hemolysis nor thrombotic events increased the risk of mortality. The incidences of bleeding and thrombosis are high during ECMO support. Laboratory sampling is a major contributor to transfusion during ECMO. Strategies to reduce the daily risk of bleeding and thrombosis, and different thresholds for transfusion, may be appropriate subjects of future trials to improve outcomes of children requiring this supportive therapy.

  3. Intestinal epithelial apoptosis initiates gut mucosal injury during extracorporeal membrane oxygenation in the newborn piglet.

    Science.gov (United States)

    MohanKumar, Krishnan; Killingsworth, Cheryl R; McIlwain, R Britt; Timpa, Joseph G; Jagadeeswaran, Ramasamy; Namachivayam, Kopperuncholan; Kurundkar, Ashish R; Kelly, David R; Garzon, Steven A; Maheshwari, Akhil

    2014-02-01

    Neonates and young infants exposed to extracorporeal circulation during extracorporeal membrane oxygenation (ECMO) and cardiopulmonary bypass are at risk of developing a systemic inflammatory response syndrome with multi-organ dysfunction. We used a piglet model of ECMO to investigate the hypothesis that epithelial apoptosis is an early event that precedes villous damage during ECMO-related bowel injury. Healthy 3-week-old piglets were subjected to ECMO for up to 8 h. Epithelial apoptosis was measured in histopathological analysis, nuclear imaging, and terminal deoxynucleotidyl transferase dUTP nick end labeling. Plasma intestinal fatty acid-binding protein (I-FABP) levels were measured by enzyme immunoassay. Intestinal mast cells were isolated by fluorescence-assisted cell sorting. Cleaved caspase-8, caspase-9, phospho-p38 MAPK, and fas ligand expression were investigated by immunohistochemistry, western blots, and reverse transcriptase-quantitative PCR. Piglet ECMO was associated with increased gut epithelial apoptosis. Extensive apoptotic changes were noted on villus tips and in scattered crypt cells after 2 h of ECMO. After 8 h, the villi were denuded and apoptotic changes were evident in a majority of crypt cells. Increased circulating I-FABP levels, a marker of gut epithelial injury, showed that epithelial injury occurred during ECMO. We detected increased cleaved caspase-8, but not cleaved caspase-9, in epithelial cells indicating that the extrinsic apoptotic pathway was active. ECMO was associated with increased fas ligand expression in intestinal mast cells, which was induced through activation of the p38 mitogen-activated protein kinase. We conclude that epithelial apoptosis is an early event that initiates gut mucosal injury in a piglet model of ECMO.

  4. Neonatal extracorporeal membrane oxygenation: Initial experience of Hospital de São João

    Directory of Open Access Journals (Sweden)

    G. Rocha

    2014-11-01

    Full Text Available The purpose of this series is to report the initial ECMO experience of the Neonatal Intensive Care Unit of Hospital de São João. The first three clinical cases are reported. Case report 1: a 39 weeks gestational age girl with severe lung hypoplasia secondary to a bilateral congenital diaphragmatic hernia. Case report 2: a 39 weeks gestational age girl with a right congenital diaphragmatic hernia and a tracheal stenosis. Case report 3: a 34 weeks gestational age boy, with 61 days of life, with a Bordetella pertussis pneumonia, severe pulmonary hypertension, shock, hyperleukocytosis and seizures. Resumo: O objetivo desta série é apresentar a experiência inicial da Unidade de Cuidados Intensivos Neonatais do Hospital de São João com ECMO no recém-nascido. São apresentados os 3 primeiros casos. Caso 1: recém-nascido de 39 semanas de idade gestacional, com hipoplasia pulmonar severa secundária a hérnia diafragmática congénita bilateral. Caso 2: recém-nascido de 39 semanas de idade gestacional, com hérnia diafragmática congénita direita e estenose traqueal. Caso 3: pré-termo de 34 semanas de idade gestacional, sexo masculino, com 61 dias de vida, com pneumonia por Bordetella pertussis, hipertensão pulmonar severa, choque, hiperleucocitose e convulsões. Keywords: Extracorporeal membrane oxygenation, Newborn, Congenital diaphragmatic hernia, Tracheal stenosis, Bordetella pertussis infection, Palavras-chave: Oxigenação por membrana extracorporal, Recém-nascido, Hérnia diafragmática congénita, Estenose traqueal, Infeção por Bordetella pertussis

  5. Successful application of extracorporeal membrane oxygenation due to pulmonary hemorrhage secondary to granulomatosis with polyangiitis

    Directory of Open Access Journals (Sweden)

    Hohenforst-Schmidt W

    2013-07-01

    Full Text Available Wolfgang Hohenforst-Schmidt,1 Arndt Petermann,2 Aikaterini Visouli,3 Paul Zarogoulidis,4 Kaid Darwiche,5 Ioanna Kougioumtzi,6 Kosmas Tsakiridis,3 Nikolaos Machairiotis,6 Markus Ketteler,2 Konstantinos Zarogoulidis,4 Johannes Brachmann11II Medical Clinic, Coburg Clinic, University of Wuerzburg, Coburg, Germany; 2Division of Nephrology, Coburg Clinic, University of Wuerzburg, Coburg, Germany; 3Cardiothoracic Surgery Department, “Saint Luke” Private Hospital, Thessaloniki, Greece; 4Pulmonary Department, “G Papanikolaou” General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece; 5Department of Interventional Pneumology, Ruhrlandklinik, West German Lung Center, University Hospital, University of Duisburg-Essen, Essen, Germany; 6Surgery Department (National Health System, University General Hospital of Alexandroupolis, Alexandroupolis, GreeceAbstract: Extracorporeal membrane oxygenation (ECMO is increasingly applied in adults with acute refractory respiratory failure that is deemed reversible. Bleeding is the most frequent complication during ECMO support. Severe pre-existing bleeding has been considered a contraindication to ECMO application. Nevertheless, there are cases of successful ECMO application in patients with multiple trauma and hemorrhagic shock or head trauma and intracranial hemorrhage. ECMO has proved to be life-saving in several cases of life-threatening respiratory failure associated with pulmonary hemorrhage of various causes, including granulomatosis with polyangiitis (Wegener’s disease. We successfully applied ECMO in a 65-year-old woman with acute life-threatening respiratory failure due to diffuse massive pulmonary hemorrhage secondary to granulomatosis with polyangiitis, manifested as severe pulmonary-renal syndrome. ECMO sustained life and allowed disease control, together with plasmapheresis, cyclophosphamide, corticoids, and renal replacement therapy. The patient was successfully weaned from ECMO

  6. Contemporary Outcomes of Extracorporeal Membrane Oxygenation Used as Bridge to Lung Transplantation.

    Science.gov (United States)

    Hakim, Ali H; Ahmad, Usman; McCurry, Kenneth R; Johnston, Douglas R; Pettersson, Gosta B; Budev, Marie; Murthy, Sudish; Blackstone, Eugene H; Tong, Michael Z

    2018-07-01

    Extracorporeal membrane oxygenation (ECMO), when used as bridge to lung transplantation, (BTT) identifies high-risk candidates. Recent advances in cannula design and patient selection fosters "awake ambulatory ECMO" as a viable option for critically ill candidates in an attempt to retard deconditioning while awaiting allografts. From 2012 to 2015, 30 patients underwent ECMO as BTT. Candidacy for ECMO was determined before listing for transplant. A dual-lumen single cannula was used first in 13 of 30 patients (43%). Of the remaining 30 patients, 6 (20%) were supported with venoarterial ECMO and 11 (37%) with venovenous ECMO, with double-site cannulation in 11 (37%), and 6 of 11 converted to a dual-lumen single cannula. All ECMO patients were managed in a dedicated heart/lung failure intensive care unit, and early aggressive physical therapy, ambulation, and spontaneous breathing trials were emphasized. BTT was successful in 26 patients (87%). In the 19 patients with dual-lumen single cannula, 5 (26%) were successfully ambulated, and 6 (32%) achieved spontaneous ventilation. Median (25th, 75th percentile) lengths of stay in the intensive care unit and hospital were 33 days (20, 46 days) and 56 days (28, 78 days), respectively, and were 20 and 31 days, respectively, in patients successfully ambulated (intensive care unit: p = 0.5; hospital: p = 0.4). Among all patients who received a transplant, 30-day, 1-year, and 3-year survival were 92%, 85%, and 80%, respectively. Among patients undergoing primary transplants, 3-year survival was 91%. ECMO as BTT has led to encouraging perioperative outcomes and early survival. Careful patient selection and early use of ECMO seems to allow for preservation of vitality while these critically ill candidates await donor organs, which may improve outcomes. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Evaluation of Altered Drug Pharmacokinetics in Critically Ill Adults Receiving Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Ha, Michael A; Sieg, Adam C

    2017-02-01

    Extracorporeal membrane oxygenation (ECMO) is a life-support modality used in patients with refractory cardiac and/or respiratory failure. A significant resurgence in the use ECMO has been seen in recent years as a result of substantial improvements in technology and survival benefit. With expanding ECMO use, a better understanding of how ECMO affects drug pharmacokinetics (PK) is necessary. The vast majority of PK studies in patients receiving ECMO have been conducted within neonatal or pediatric populations or within a controlled environment (e.g., in vitro or ex vivo). Because of significant differences in absorption, distribution, metabolism, and excretion, it may be inappropriate to extrapolate these PK data to adults. Thus, the aims of this review are to evaluate the changes in drug PK during ECMO and to summarize the available PK data for common drugs used in the adult critically ill patients during ECMO support. A search of the PubMed (1965-July 2016), EMBASE (1965-July 2016), and Cochrane Controlled Trial Register databases was performed. All relevant studies describing PK alterations during ECMO in ex vivo experiments and in adults were included. Evaluation of the data indicated that drug PK in adults receiving ECMO support may be significantly altered. Factors influencing these alterations are numerous and have intricate relationships with each other but can generally be classified as ECMO circuit factors, drug factors, and patient factors. Commonly used drugs in these patients include antimicrobials, sedatives, and analgesics. PK data for most of these drugs are generally lacking; however, recent research efforts in this patient population have provided some limited guidance in drug dosing. With an improved understanding of altered drug PK secondary to ECMO therapy, optimization of pharmacotherapy within this critically ill population continues to move forward. © 2016 Pharmacotherapy Publications, Inc.

  8. The influence of advanced age on venous-arterial extracorporeal membrane oxygenation outcomes.

    Science.gov (United States)

    Salna, Michael; Takeda, Koji; Kurlansky, Paul; Ikegami, Hirohisa; Fan, Liqiong; Han, Jiho; Stein, Samantha; Topkara, Veli; Yuzefpolskaya, Melana; Colombo, Paolo C; Karmpaliotis, Dimitrios; Naka, Yoshifumi; Kirtane, Ajay J; Garan, Arthur R; Takayama, Hiroo

    2018-01-22

    Ethical and health care economic concerns surround the use of venous-arterial extracorporeal membrane oxygenation (VA-ECMO) in elderly patients. Patients requiring VA-ECMO are often in critical condition and the decision to cannulate is time-sensitive. We investigated the relationship between age and VA-ECMO outcomes to better inform this decision. This is a retrospective study of 355 patients placed on VA-ECMO between March 2007 and August 2016 at our institution. Using piecewise modelling, age became associated with in-hospital mortality after 63 years. Based on further analysis with the χ2 statistic maximization, patients were divided into 2 age groups: ≤72 years old [Group Y (Young), n = 310] and >72 years old [Group O (Old), n = 45]. Multivariable logistic regression was performed to identify preoperative predictors of in-hospital mortality. Patients over the age of 72 had a significantly higher prevalence of comorbidities, including coronary disease, previous strokes and chronic kidney disease. Weaning from ECMO was achieved in 76% of Group Y and 47% of Group O (P 72 years as independent predictors of mortality (age >72 years: odds ratio 2.71, 95% confidence interval 1.22-6.00; P = 0.01). VA-ECMO in-hospital mortality is considerable across all age groups. However, age only becomes associated with mortality after 63 years and rises dramatically after 72 years. This study provides useful insight into these time-sensitive decisions for the development of possible practice guidelines. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Effect of breathing oxygen-enriched air on exercise performance in patients with precapillary pulmonary hypertension: randomized, sham-controlled cross-over trial.

    Science.gov (United States)

    Ulrich, Silvia; Hasler, Elisabeth D; Saxer, Stéphanie; Furian, Michael; Müller-Mottet, Séverine; Keusch, Stephan; Bloch, Konrad E

    2017-04-14

    The purpose of the current trial was to test the hypothesis that breathing oxygen-enriched air increases exercise performance of patients with pulmonary arterial or chronic thrombo-embolic pulmonary hypertension (PAH/CTEPH) and to investigate involved mechanisms. Twenty-two patients with PAH/CTEPH, eight women, means ± SD 61 ± 14 years, resting mPAP 35 ± 9mmHg, PaO2 ambient air >7.3 kPa, underwent four bicycle ergospirometries to exhaustion on different days, while breathing oxygen-enriched (FiO2 0.50, hyperoxia) or ambient air (FiO2 0.21, normoxia) using progressively increased or constant load protocols (with 75% maximal work rate under FiO2 0.21), according to a randomized, sham-controlled, single-blind, cross-over design. ECG, pulmonary gas-exchange, arterial blood gases, cerebral and quadriceps muscle tissue oxygenation (CTO and QMTO) by near-infrared spectroscopy were measured. In ramp exercise, maximal work rate increased from 113 ± 38 W with normoxia to 132 ± 48 W with hyperoxia, mean difference 19.7 (95% CI 10.5-28.9) W, P endurance increased from 571 ± 443 to 1242 ± 514 s, mean difference 671 (95% CI 392-951) s, P < 0.001. At end-exercise with hyperoxia PaO2, CTO, QMTO, and PaCO2 were increased, and ventilatory equivalents for CO2 were reduced while the physiological dead space/tidal volume ratio remained unchanged. In patients with PAH/CTEPH, breathing oxygen-enriched air provides major increases in exercise performance. This is related to an improved arterial oxygenation that promotes oxygen availability in muscles and brain and to a reduction of the excessive ventilatory response to exercise thereby enhancing ventilatory efficiency. Patients with PAH/CTEPH may therefore benefit from oxygen therapy during daily physical activities and training. clinicaltrials.gov Identifier: NCT01748474. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions

  10. Species specificity of resistance to oxygen diffusion in thin cuticular membranes from amphibious plants

    DEFF Research Database (Denmark)

    Frost-Christensen, Henning; Jørgensen, Lise Bolt; Floto, Franz

    2003-01-01

    oxygen, diffusion, cuticula, amphibious plants, Hygrophila, Berula, Lobelia, Mentha, Potamogeton, Veronica, aquatic plants, submerged plants......oxygen, diffusion, cuticula, amphibious plants, Hygrophila, Berula, Lobelia, Mentha, Potamogeton, Veronica, aquatic plants, submerged plants...

  11. Pressure balanced type membrane covered polarographic oxygen detectors for use in high temperature-high pressure water, (1)

    International Nuclear Information System (INIS)

    Nakayama, Norio; Uchida, Shunsuke

    1984-01-01

    A pressure balanced type membrane covered polarographic oxygen detector was developed to determine directly oxygen concentrations in high temperature, high pressure water without cooling and pressure reducing procedures. The detector is characterized by the following features: (1) The detector body and the membrane for oxygen penetration are made of heat resistant resin. (2) The whole detector body is contained in a pressure chamber where interior and exterior pressures of the detector are balanced. (3) Thermal expansion of the electrolyte is absorbed by deformation of a diaphragm attached to the detector bottom. (4) The effect of dissolved Ag + on the signal current is eliminated by applying a guard electrode. As a result of performance tests at elevated temperature, it was demonstrated that a linear relationship between oxygen concentration and signal current was obtained up to 285 0 C, which was stabilized by the guard electrode. The minimum O 2 concentration detectable was 0.03ppm (9.4 x 10 -7 mol/kg). (author)

  12. Impact of oxygen toxic action on the erythrocyte membrane and possibility of estimating central nervous system function disturbances

    Directory of Open Access Journals (Sweden)

    Belić Branislava

    2011-01-01

    Full Text Available Background/Aim. Prolonged exposure to hyperbaric oxygen leads to changes of erythrocytes shape as a consequence of toxic effects of oxygen on the erythrocyte membrane. The aim of this study was to examine the association between occurance of pathological forms of erythrocytes at different time from the start of hyperbaric oxygenation and the moment of convulsions occurrence, an interrelationship of different pathological forms of erythrocytes during exposure to hyperbaric oxygenation, as well as the correlation between the presence of ruptured erythrocytes and function of central nervous system (CNS after completion of hyperbaric treatment. Methods. Sixty laboratory mice, Mus musculus, were exposed to the wholly-oxygen pressure of 3.5 absolute atmospheres (ATA. Blood was collected at the 32nd, 34th, 36th, 38th and 40th minutes after the exposure to oxygen. Pathological forms of erythrocytes were examined by electron microscopy. A moment of convulsions occurrence was registered in all animals. After decompression neurological examinations of experimental animals were perfomed. The Pearson's coefficient of correlation, and linear regression equations for the parameters outlined in the aim of the study were calculated. Results. Hyperbaric oxygen caused damages of erythrocytes at the 34th minute after beginning of the treatment. Various forms of abnormal red blood cells occured, and immediately before the occurrence of irreversible changes (erythrocyte membrane rupture echinocyte shape was dominated. A significant correlation between the number of damaged red blood cells at 34th minute and their number at the 36th, 38th and 40th minute was found. Convulsions were diagnosed significantly earlier in mice with a greater number of damaged red blood cells (p < 0.01. There was a negative correlation between the number of irreversiblly damaged red blood cells (ruptured at the 40th minute and neurological score in the studied animals (p < 0.05. Conclusion

  13. Extracorporeal Membrane Oxygenation Cannula Malposition in the Azygos Vein in a Neonate with Right-Sided Congenital Diaphragmatic Hernia

    Directory of Open Access Journals (Sweden)

    Seung Jun Choi

    2016-05-01

    Full Text Available Malposition of the extracorporeal membrane oxygenation (ECMO venous cannula in the azygos vein is not frequently reported. We hereby present such a case, which occurred in a neonate with right-sided congenital diaphragmatic hernia. Despite ECMO application, neither adequate flow nor sufficient oxygenation was achieved. On the cross-table lateral chest radiograph, the cannula tip was identified posterior to the heart silhouette, which implied malposition of the cannula in the azygos vein. After repositioning the cannula, the target flow and oxygenation were successfully achieved. When sufficient venous flow is not achieved, as in our case, clinicians should be alerted so they can identify the cannula tip location on lateral chest radiograph and confirm whether malposition in the azygos vein is the cause of the ineffective ECMO.

  14. Long term analysis of the biomass content in the feed of a waste-to-energy plant with oxygen-enriched combustion air.

    Science.gov (United States)

    Fellner, Johann; Cencic, Oliver; Zellinger, Günter; Rechberger, Helmut

    2011-10-01

    Thermal utilization of municipal solid waste and commercial wastes has become of increasing importance in European waste management. As waste materials are generally composed of fossil and biogenic materials, a part of the energy generated can be considered as renewable and is thus subsidized in some European countries. Analogously, CO(2) emissions of waste incinerators are only partly accounted for in greenhouse gas inventories. A novel approach for determining these fractions is the so-called balance method. In the present study, the implementation of the balance method on a waste-to-energy plant using oxygen-enriched combustion air was investigated. The findings of the 4-year application indicate on the one hand the general applicability and robustness of the method, and on the other hand the importance of reliable monitoring data. In particular, measured volume flows of the flue gas and the oxygen-enriched combustion air as well as corresponding O(2) and CO(2) contents should regularly be validated. The fraction of renewable (biogenic) energy generated throughout the investigated period amounted to between 27 and 66% for weekly averages, thereby denoting the variation in waste composition over time. The average emission factor of the plant was approximately 45 g CO(2) MJ(-1) energy input or 450 g CO(2) kg(-1) waste incinerated. The maximum error of the final result was about 16% (relative error), which was well above the error (<8%) of the balance method for plants with conventional oxygen supply.

  15. Biodegradation of Various Aromatic Compounds by Enriched Bacterial Cultures: Part B--Nitrogen-, Sulfur-, and Oxygen-Containing Heterocyclic Aromatic Compounds.

    Science.gov (United States)

    Oberoi, Akashdeep Singh; Philip, Ligy; Bhallamudi, S Murty

    2015-07-01

    Present study focused on the biodegradation of various heterocyclic nitrogen, sulfur, and oxygen (NSO) compounds using naphthalene-enriched culture. Target compounds in the study were pyridine, quinoline, benzothiophene, and benzofuran. Screening studies were carried out using different microbial consortia enriched with specific polycyclic aromatic hydrocarbon (PAH) and NSO compounds. Among different microbial consortia, naphthalene-enriched culture was the most efficient consortium based on high substrate degradation rate. Substrate degradation rate with naphthalene-enriched culture followed the order pyridine > quinoline > benzofuran > benzothiophene. Benzothiophene and benzofuran were found to be highly recalcitrant pollutants. Benzothiophene could not be biodegraded when concentration was above 50 mg/l. It was observed that 2-(1H)-quinolinone, benzothiophene-2-one, and benzofuran-2,3-dione were formed as metabolic intermediates during biodegradation of quinoline, benzothiophene, and benzofuran, respectively. Quinoline-N and pyridine-N were transformed into free ammonium ions during the biodegradation process. Biodegradation pathways for various NSO compounds are proposed. Monod inhibition model was able to simulate single substrate biodegradation kinetics satisfactorily. Benzothiophene and benzofuran biodegradation kinetics, in presence of acetone, was simulated using a generalized multi-substrate model.

  16. Possible central nervous system oxygen toxicity seizures among US recreational air or enriched air nitrox open circuit diving fatalities 2004-2013.

    Science.gov (United States)

    Buzzacott, P; Denoble, P J

    2017-01-01

    The first diver certification programme for recreational 'enriched air nitrox' (EAN) diving was released in 1985. Concerns were expressed that many EAN divers might suffer central nervous system (CNS) oxygen toxicity seizures and drown. US fatalities on open-circuit scuba occurring between 2004-2013, where the breathing gas was either air or EAN, were identified. Causes of death and preceding circumstances were examined by a medical examiner experienced in diving autopsies. Case notes were searched for witnessed seizures at elevated partial pressures of oxygen. The dataset comprised 344 air divers (86%) and 55 divers breathing EAN (14%). EAN divers' fatal dives were deeper than air divers' (28 msw vs 18 msw, p < 0.0001). Despite this, of the 249 cases where a cause of death was established, only three EAN divers were considered to have possibly died following CNS oxygen toxicity seizures at depth (ppO2 132, 142 and 193 kPa). The analysis of recreational diving fatalities in the US over 10 years found just one death likely from CNS oxygen toxicity among EAN divers. A further two possible, although unlikely, cases were also found. Fears of commonplace CNS oxygen toxicity seizures while EAN diving have not apparently been realized.

  17. Seawater-driven forward osmosis for enriching nitrogen and phosphorous in treated municipal wastewater: effect of membrane properties and feed solution chemistry.

    Science.gov (United States)

    Xue, Wenchao; Tobino, Tomohiro; Nakajima, Fumiyuki; Yamamoto, Kazuo

    2015-02-01

    Seawater-driven forward osmosis (FO) is considered to be a novel strategy to concentrate nutrients in treated municipal wastewater for further recovery as well as simultaneous discharge of highly purified wastewater into the sea with low cost. As a preliminary test, the performance of FO membranes in concentrating nutrients was investigated by both batch experiments and model simulation approaches. With synthetic seawater as the draw solution, the dissolved organic carbon, phosphate, and ammonia in the effluent from a membrane bioreactor (MBR) treating municipal wastewater were 2.3-fold, 2.3-fold, and 2.1-fold, respectively, concentrated by the FO process with approximately 57% of water reduction. Most of the dissolved components, including trace metals in the MBR effluent, were highly retained (>80%) in the feed side, indicating high water quality of permeate to be discharged. The effect of membrane properties on the nutrient enrichment performance was investigated by comparing three types of FO membranes. Interestingly, a polyamide membrane possessing a high negative charge demonstrated a poor capability of retaining ammonia, which was hypothesized because of an ion exchange-like mechanism across the membrane prompted by the high ionic concentration of the draw solution. A feed solution pH of 7 was demonstrated to be an optimum condition for improving the overall retention of nutrients, especially for ammonia because of the pH-dependent speciation of ammonia/ammonium forms. The modeling results showed that higher than 10-fold concentrations of ammonia and phosphate are achievable by seawater-driven FO with a draw solution to feed solution volume ratio of 2:1. The enriched municipal wastewater contains nitrogen and phosphorous concentrations comparable with typical animal wastewater and anaerobic digestion effluent, which are used for direct nutrient recovery. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Oxygen permeation in thin, dense Ce0.9Gd0.1O 1.95- membranes I. Model study

    DEFF Research Database (Denmark)

    Chatzichristodoulou, Christodoulos; Søgaard, Martin; Hendriksen, Peter Vang

    2011-01-01

    at the feed and permeate side of the membrane, related to the gaseous oxygen reduction and fuel oxidation, respectively, as well as the gas conversion and gas diffusion resistances in the porous support structure at the permeate side. The temperature and oxygen activity dependence of the oxide ionic...... was analyzed by a separation of the various losses. The chemical expansion of Ce 0.9Gd0.1O1.95-δ under operation was estimated from the calculated oxygen activity and nonstoichiometry profiles inside the membrane. © 2011 The Electrochemical Society.......A model of a supported planar Ce0.9Gd0.1O 1.95-δ oxygen membrane in a plug-flow setup was constructed and a sensitivity analysis of its performance under varying operating conditions and membrane parameters was performed. The model takes into account the driving force losses at the catalysts...

  19. Lung transplantation for idiopathic pulmonary arterial hypertension on intraoperative and postoperatively prolonged extracorporeal membrane oxygenation provides optimally controlled reperfusion and excellent outcome.

    Science.gov (United States)

    Moser, Bernhard; Jaksch, Peter; Taghavi, Shahrokh; Muraközy, Gabriella; Lang, Georg; Hager, Helmut; Krenn, Claus; Roth, Georg; Faybik, Peter; Bacher, Andreas; Aigner, Clemens; Matilla, José R; Hoetzenecker, Konrad; Hacker, Philipp; Lang, Irene; Klepetko, Walter

    2018-01-01

    Lung transplantation for idiopathic pulmonary arterial hypertension has the highest reported postoperative mortality of all indications. Reasons lie in the complexity of treatment of these patients and the frequent occurrence of postoperative left ventricular failure. Transplantation on intraoperative extracorporeal membrane oxygenation support instead of cardiopulmonary bypass and even more the prolongation of extracorporeal membrane oxygenation into the postoperative period helps to overcome these problems. We reviewed our experience with this concept. All patients undergoing bilateral lung transplantation for idiopathic pulmonary arterial hypertension on intraoperative extracorporeal membrane oxygenation with or without prophylactic extracorporeal membrane oxygenation prolongation into the postoperative period between January 2000 and December 2014 were retrospectively analysed. Forty-one patients entered the study. Venoarterial extracorporeal membrane oxygenation support was prolonged into the postoperative period for a median of 2.5 days (range 1-40). Ninety-day, 1-, 3- and 5-year survival rates for the patient collective were 92.7%, 90.2%, 87.4% and 87.4%, respectively. When compared with 31 patients with idiopathic pulmonary arterial hypertension transplanted in the same period of time without prolongation of extracorporeal membrane oxygenation into the postoperative period, the results compared favourably (83.9%, 77.4%, 77.4%, and 77.4%; P = 0.189). Furthermore, these results are among the best results ever reported for this particularly difficult patient population. Bilateral lung transplantation for idiopathic pulmonary arterial hypertension with intraoperative venoarterial extracorporeal membrane oxygenation support seems to provide superior outcome compared with the results reported about the use of cardiopulmonary bypass. Prophylactic prolongation of venoarterial extracorporeal membrane oxygenation into the early postoperative period provides

  20. Improved Outcome of Cardiac Extracorporeal Membrane Oxygenation in Infants and Children Using Magnetic Levitation Centrifugal Pumps.

    Science.gov (United States)

    Luciani, Giovanni Battista; Hoxha, Stiljan; Torre, Salvatore; Rungatscher, Alessio; Menon, Tiziano; Barozzi, Luca; Faggian, Giuseppe

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) has traditionally been and, for the most part, still is being performed using roller pumps. Use of first-generation centrifugal pumps has yielded controversial outcomes, perhaps due to mechanical properties of the same and the ensuing risk of hemolysis and renal morbidity. Latest-generation centrifugal pumps, using magnetic levitation (ML), exhibit mechanical properties which may have overcome limitations of first-generation devices. This retrospective study aimed to assess the safety and efficacy of veno-arterial (V-A) ECMO for cardiac indications in neonates, infants, and children, using standard (SP) and latest-generation ML centrifugal pumps. Between 2002 and 2014, 33 consecutive neonates, infants, and young children were supported using V-A ECMO for cardiac indications. There were 21 males and 12 females, with median age of 29 days (4 days-5 years) and a median body weight of 3.2 kg (1.9-18 kg). Indication for V-A ECMO were acute circulatory collapse in ICU or ward after cardiac repair in 16 (49%) patients, failure to wean after repair of complex congenital heart disease in 9 (27%), fulminant myocarditis in 4 (12%), preoperative sepsis in 2 (6%), and refractory tachy-arrhythmias in 2 (6%). Central cannulation was used in 27 (81%) patients and peripheral in 6. Seven (21%) patients were supported with SP and 26 (79%) with ML centrifugal pumps. Median duration of support was 82 h (range 24-672 h), with 26 (79%) patients weaned from support. Three patients required a second ECMO run but died on support. Seventeen (51%) patients required peritoneal dialysis for acute renal failure. Overall survival to discharge was 39% (13/33 patients). All patients with fulminant myocarditis and with refractory arrhythmias were weaned, and five (83%) survived, whereas no patient supported for sepsis survived. Risk factors for hospital mortality included lower (pumps in infants and children yields outcomes absolutely comparable to

  1. U.S. and International In-Hospital Costs of Extracorporeal Membrane Oxygenation: a Systematic Review.

    Science.gov (United States)

    Harvey, Michael J; Gaies, Michael G; Prosser, Lisa A

    2015-08-01

    The in-hospital costs of extracorporeal membrane oxygenation (ECMO) have not been well established. To evaluate the in-hospital costs of ECMO technology in both US and non-US settings for all patient types. Systematic review of English-language articles, using the PubMed, Embase, Web of Science and EconLit databases. Searches consisted of the terms 'ECMO' AND 'health expenditures' or 'resource use' or 'costs' or 'cost analysis' or 'cost(-)effectiveness' or 'cost(-)benefit' or 'cost(-)utility' or 'economic(-)evaluation' or 'economic' or 'QALY' or 'cost per quality-adjusted life year'. Only full scientific research articles were included. The exclusion criteria included papers that focused on pumpless ECMO, simulation training or decision support systems; papers that did not include human subjects or were not written in English; papers that did not mention ECMO, costs, economics or resource utilization; and papers that included only outside-hospital, infrastructure capital or device capital costs. Data extraction was completed by one author, using predefined criteria. From the database searches, 1371 results were returned, 226 records underwent a full review and 18 studies were included in the final review. Three papers studied adult populations, two studied adult and paediatric populations, five studied only paediatric populations, one studied a paediatric and neonatal population, and the remaining seven exclusively examined ECMO in neonatal populations. The sample sizes ranged from 8 to 8753 patients. ECMO for respiratory conditions was the most common diagnosis category, followed by congenital diaphragmatic hernia (CDH) and then cardiac conditions. Most papers (n = 14) used retrospective cost collection. Only eight papers stated the perspective of the cost analysis. The results show a large variation in the cost of ECMO over multiple cost categories (e.g., range of total in-hospital costs of treatment: USD 42,554-537,554 [in 2013 values]). In the U.S.A., the

  2. Nanotexture Optimization by Oxygen Plasma of Mesoporous Silica Thin Film for Enrichment of Low Molecular Weight Peptides Captured from Human Serum

    Science.gov (United States)

    Hu, Ye; Peng, Yang; Brousseau, Louis; Bouamrani, Ali; Liu, Xuewu; Ferrari, Mauro

    2010-01-01

    This study investigated the optimization of mesoporous silica thin films by nanotexturing using oxygen plasma versus thermal oxidation. Calcination in oxygen plasma provides superior control over pore formation with regard to the pore surface and higher fidelity to the structure of the polymer template. The resulting porous film offers an ideal substrate for the selective partitioning of peptides from complex mixtures. The improved chemico-physical characteristics of porous thin films (pore size distribution, nanostructure, surface properties and pore connectivity) were systematically characterized with XRD, Ellipsometry, FTIR, TEM and N2 adsorption/desorption. The enrichment of low molecular weight proteins captured from human serum on mesoporous silica thin films fabricated by both methodologies were investigated by comparison of their MALDI-TOF MS profiles. This novel on-chip fractionation technology offers advantages in recovering the low molecular weight peptides from human serum, which has been recognized as an informative resource for early diagnosis of cancer and other diseases. PMID:21179395

  3. Methodologies For Characterising Mixed Conducting Oxides For Oxygen Membrane And SOFC Cathode Application

    DEFF Research Database (Denmark)

    Hendriksen, Peter Vang; Søgaard, Martin; Plonczak, Pawel

    2012-01-01

    Two methods for detailed characterization of the process of oxygen exchange between the gas phase and a mixed conducting solid oxide are discussed. First, the use of solid electrolyte probes for measuring the change in oxygen activity over the surface of a mixed conductor is presented and advanta......Two methods for detailed characterization of the process of oxygen exchange between the gas phase and a mixed conducting solid oxide are discussed. First, the use of solid electrolyte probes for measuring the change in oxygen activity over the surface of a mixed conductor is presented...

  4. Biofilm spatial organization by the emerging pathogen Campylobacter jejuni: comparison between NCTC 11168 and 81-176 strains under microaerobic and oxygen-enriched conditions.

    Science.gov (United States)

    Turonova, Hana; Briandet, Romain; Rodrigues, Ramila; Hernould, Mathieu; Hayek, Nabil; Stintzi, Alain; Pazlarova, Jarmila; Tresse, Odile

    2015-01-01

    During the last years, Campylobacter has emerged as the leading cause of bacterial foodborne infections in developed countries. Described as an obligate microaerophile, Campylobacter has puzzled scientists by surviving a wide range of environmental oxidative stresses on foods farm to retail, and thereafter intestinal transit and oxidative damage from macrophages to cause human infection. In this study, confocal laser scanning microscopy (CLSM) was used to explore the biofilm development of two well-described Campylobacter jejuni strains (NCTC 11168 and 81-176) prior to or during cultivation under oxygen-enriched conditions. Quantitative and qualitative appraisal indicated that C. jejuni formed finger-like biofilm structures with an open ultrastructure for 81-176 and a multilayer-like structure for NCTC 11168 under microaerobic conditions (MAC). The presence of motile cells within the biofilm confirmed the maturation of the C. jejuni 81-176 biofilm. Acclimation of cells to oxygen-enriched conditions led to significant enhancement of biofilm formation during the early stages of the process. Exposure to these conditions during biofilm cultivation induced an even greater biofilm development for both strains, indicating that oxygen demand for biofilm formation is higher than for planktonic growth counterparts. Overexpression of cosR in the poorer biofilm-forming strain, NCTC 11168, enhanced biofilm development dramatically by promoting an open ultrastructure similar to that observed for 81-176. Consequently, the regulator CosR is likely to be a key protein in the maturation of C. jejuni biofilm, although it is not linked to oxygen stimulation. These unexpected data advocate challenging studies by reconsidering the paradigm of fastidious requirements for C. jejuni growth when various subpopulations (from quiescent to motile cells) coexist in biofilms. These findings constitute a clear example of a survival strategy used by this emerging human pathogen.

  5. Biofilm spatial organization by the emerging pathogen Campylobacter jejuni: comparison between NCTC 11168 and 81-176 strains under microaerobic and oxygen-enriched conditions

    Directory of Open Access Journals (Sweden)

    Hana eTuronova

    2015-07-01

    Full Text Available During the last years, Campylobacter has emerged as the leading cause of bacterial foodborne infections in developed countries. Described as an obligate microaerophile, Campylobacter has puzzled scientists by surviving a wide range of environmental oxidative stresses on foods farm to retail, and thereafter intestinal transit and oxidative damage from macrophages to cause human infection. In this study, confocal laser scanning microscopy was used to explore the biofilm development of two well-described Campylobacter jejuni strains (NCTC 11168 and 81-176 prior to or during cultivation under oxygen-enriched conditions. Quantitative and qualitative appraisal indicated that C. jejuni formed finger-like biofilm structures with an open ultrastructure for 81-176 and a multilayer-like structure for NCTC 11168 under microaerobic conditions. The presence of motile cells within the biofilm confirmed the maturation of the C. jejuni 81-176 biofilm. Acclimation of cells to oxygen-enriched conditions led to significant enhancement of biofilm formation during the early stages of the process. Exposure to these conditions during biofilm cultivation induced an even greater biofilm development for both strains, indicating that oxygen demand for biofilm formation is higher than for planktonic growth counterparts. Overexpression of cosR in the poorer biofilm-forming strain, NCTC 11168, enhanced biofilm development dramatically by promoting an open ultrastructure similar to that observed for 81-176. Consequently, the regulator CosR is likely to be a key protein in the maturation of C. jejuni biofilm, although it is not linked to oxygen stimulation. These unexpected data advocate challenging studies by reconsidering the paradigm of fastidious requirements for C. jejuni growth when various subpopulations (from quiescent to motile cells coexist in biofilms. These findings constitute a clear example of a survival strategy used by this emerging human pathogen.

  6. Inhibitory effects of polyphenol-enriched extract from Ziyang tea against human breast cancer MCF-7 cells through reactive oxygen species-dependent mitochondria molecular mechanism

    Directory of Open Access Journals (Sweden)

    Wenfeng Li

    2016-07-01

    Full Text Available A polyphenol-enriched extract from selenium-enriched Ziyang green tea (ZTP was selected to evaluate its antitumor effects against human breast cancer MCF-7 cells. In ZTP, (−-epigallocatechin gallate (28.2% was identified as the major catechin, followed by (−-epigallocatechin (5.7% and (−-epicatechin gallate (12.6%. ZTP was shown to inhibit MCF-7 cell proliferation (half maximal inhibitory concentration, IC50 = 172.2 μg/mL by blocking cell-cycle progression at the G0/G1 phase and inducing apoptotic death. Western blotting assay indicated that ZTP induced cell-cycle arrest by upregulation of p53 and reduced the expression of CDK2 in MCF-7 cells. ZTP-caused cell apoptosis was associated with an increase in Bax/Bcl-2 ratio, and activation of caspase-3 and -9. MCF-7 cells treated with ZTP also showed an overproduction of reactive oxygen species, suggesting that reactive oxygen species played an important role in the induction of apoptosis in MCF-7 cells. This is the first report showing that ZTP is a potential novel dietary agent for cancer chemoprevention or chemotherapy.

  7. Plasma Deposited Thin Iron Oxide Films as Electrocatalyst for Oxygen Reduction Reaction in Proton Exchange Membrane Fuel Cells

    Directory of Open Access Journals (Sweden)

    Lukasz JOZWIAK

    2017-02-01

    Full Text Available The possibility of using plasma deposited thin films of iron oxides as electrocatalyst for oxygen reduction reaction (ORR in proton exchange membrane fuel cells (PEMFC was examined. Results of energy-dispersive X-ray spectroscopy (EDX and X-ray photoelectron spectroscopy (XPS analysis indicated that the plasma deposit consisted mainly of FeOX structures with the X parameter close to 1.5. For as deposited material iron atoms are almost exclusively in the Fe3+ oxidation state without annealing in oxygen containing atmosphere. However, the annealing procedure can be used to remove the remains of carbon deposit from surface. The single cell test (SCT was performed to determine the suitability of the produced material for ORR. Preliminary results showed that power density of 0.23 mW/cm2 could be reached in the tested cell.DOI: http://dx.doi.org/10.5755/j01.ms.23.1.14406

  8. The role of sacrificial fugitives in thermoplastic extrusion feedstocks onproperties of MgO supports for oxygen transport membranes

    DEFF Research Database (Denmark)

    Kothanda Ramachandran, Dhavanesan; Kwok, Kawai; Søgaard, Martin

    2015-01-01

    2014AbstractThree different compositions of MgO compounds were investigated for use in oxygen transport membranes. Porous MgO supports were extruded using different kind (size, morphology and chemistry) of pore formers: A flaky graphite, a spherical graphite and ideal spheres of PMMA. The influence...... of the pore former on microstructure, gas permeation and the mechanical properties for various sintering temperatures were investigated.The gas permeation behavior of the MgO supports was highly dependent on pore neck size and total open porosity. MgO substrate, with 20% spherical graphite as a pore former...

  9. Fatal air embolism as complication of percutaneous dilatational tracheostomy on venovenous extracorporeal membrane oxygenation, two case reports.

    Science.gov (United States)

    Lother, Achim; Wengenmayer, Tobias; Benk, Christoph; Bode, Christoph; Staudacher, Dawid L

    2016-07-11

    Tracheostomy is recommended in case of prolonged mechanical ventilation. Therefore, most patients with an indication for venovenous extracorporeal membrane oxygenation (ECMO) will also have an indication for tracheostomy. We report 2 cases of fatal air embolism into the ECMO system as complication of percutaneous dilatational tracheostomy. Both patients had an AVALON ELITE® bi-caval cannula implanted draining blood from the vena cava superior and inferior. Since there is limited safety data on this specific group of patients, a routine early dilatational tracheostomy might be associated with a significant risk.

  10. Successful Left-Heart Decompression during Extracorporeal Membrane Oxygenation in an Adult Patient by Percutaneous Transaortic Catheter Venting

    Directory of Open Access Journals (Sweden)

    Tae Hee Hong

    2015-06-01

    Full Text Available Venoarterial extracorporeal membrane oxygenation (VA ECMO is widely used in patients with cardiogenic shock. Insufficient decompression of the left ventricle (LV is considered a major factor preventing adequate LV recovery. A 40-year-old male was diagnosed with acute myocardial infarction, and revascularization was performed using percutaneous stenting. However, cardiogenic shock occurred, and VA ECMO was initiated. Severe LV failure developed, and percutaneous transaortic catheter venting (TACV was incorporated into the venous circuit of VA ECMO under transthoracic echocardiography guidance. The patient was successfully weaned from VA ECMO. Percutaneous TACV is an effective, relatively noninvasive, and rapid method of LV decompression in patients undergoing VA ECMO.

  11. Right ventricular rupture and tamponade caused by malposition of the Avalon cannula for venovenous extracorporeal membrane oxygenation

    Directory of Open Access Journals (Sweden)

    Hirose Hitoshi

    2012-04-01

    Full Text Available Abstract Placement of the Avalon Elite bicaval dual lumen cannula for venovenous extracorporeal membrane oxygenation (VV-ECMO via the internal jugular vein requires precise positioning of the cannula tip in the inferior vena cava with echocardiography or fluoroscopy guidance. Correct guidewire placement is clearly the key first step in assuring proper advancement of the cannula. We report a case of unexpected wire migration into the right ventricle at the time of final cannula advancement, resulting in right ventricular rupture and tamponade. Transesophageal echocardiography is an important monitoring modality for appropriate placement of the VV-ECMO guidewire and Avalon cannula, and in particular, for early identification of potential complications.

  12. In reply to: "Intra-aortic balloon pump protects against hydrostatic pulmonary oedema during peripheral venoarterial-extracorporeal membrane oxygenation".

    Science.gov (United States)

    Privratsky, Jamie R; Diaz, Sebastian; Nicoara, Alina; Daneshmand, Mani A

    2018-05-01

    Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is an increasingly utilized life-saving measure. However, left-ventricular distention from inadequate left-ventricular off-loading can lead to unwanted pulmonary and cardiac complications. We are writing to indicate our agreement with a recent article by Brechot et al. published in the June 2017 issue where the authors demonstrated that intra-aortic balloon pump provides mechanical support to off-load the left ventricle during VA-ECMO, which prevents pulmonary edema.

  13. Stent Placement in a Neonate with Sano Modification of the Norwood using Semi-Elective Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Mustafa Gulgun

    Full Text Available Abstract Extracorporeal membrane oxygenation (ECMO is a well-established tool of cardiopulmonary circulatory support for cardiopulmonary failure in children and adults. It has been used as a supportive strategy during interventional procedures in neonates with congenital heart disease. Herein, we describe a neonate with hypoplastic left heart syndrome who underwent stenting of the Sano shunt and left pulmonary artery after Norwood Sano operation using intra-procedural ECMO support. The use of ECMO as a bridge to recovery might be a feasible and reasonably safe adjunctive approach in the treatment of complications in selective case of neonates having undergone the Norwood Sano procedure.

  14. Numerical simulation of ion transport membrane reactors: Oxygen permeation and transport and fuel conversion

    KAUST Repository

    Hong, Jongsup; Kirchen, Patrick; Ghoniem, Ahmed F.

    2012-01-01

    Ion transport membrane (ITM) based reactors have been suggested as a novel technology for several applications including fuel reforming and oxy-fuel combustion, which integrates air separation and fuel conversion while reducing complexity

  15. The influence of selected parameters on the efficiency and economic charactersistics of the oxy-type coal unit with a membrane-cryogenic oxygen separator

    Directory of Open Access Journals (Sweden)

    Kotowicz Janusz

    2016-03-01

    Full Text Available In this paper a 600 MW oxy-type coal unit with a pulverized bed boiler and a membrane-cryogenic oxygen separator and carbon capture installation was analyzed. A membrane-cryogenic oxygen separation installation consists of a membrane module and two cryogenic distillation columns. In this system oxygen is produced with the purity equal to 95%. Installation of carbon capture was based on the physical separation method and allows to reduce the CO2 emission by 90%. In this work the influence of the main parameter of the membrane process – the selectivity coefficient, on the efficiency of the coal unit was presented. The economic analysis with the use of the break-even point method was carried out. The economic calculations were realized in view of the break-even price of electricity depending on a coal unit availability.

  16. Toward enhanced hydrogen generation from water using oxygen permeating LCF membranes

    KAUST Repository

    Wu, Xiao-Yu; Chang, Le; Uddi, Mruthunjaya; Kirchen, Patrick; Ghoniem, Ahmed F.

    2015-01-01

    and flow rates on the feed and sweep sides on the water thermolysis rate and oxygen flux. A single step reaction mechanism is proposed for surface reactions, and three-resistance permeation models are derived. Results show that water thermolysis

  17. Gag induces the coalescence of clustered lipid rafts and tetraspanin-enriched microdomains at HIV-1 assembly sites on the plasma membrane.

    Science.gov (United States)

    Hogue, Ian B; Grover, Jonathan R; Soheilian, Ferri; Nagashima, Kunio; Ono, Akira

    2011-10-01

    The HIV-1 structural protein Gag associates with two types of plasma membrane microdomains, lipid rafts and tetraspanin-enriched microdomains (TEMs), both of which have been proposed to be platforms for HIV-1 assembly. However, a variety of studies have demonstrated that lipid rafts and TEMs are distinct microdomains in the absence of HIV-1 infection. To measure the impact of Gag on microdomain behaviors, we took advantage of two assays: an antibody-mediated copatching assay and a Förster resonance energy transfer (FRET) assay that measures the clustering of microdomain markers in live cells without antibody-mediated patching. We found that lipid rafts and TEMs copatched and clustered to a greater extent in the presence of membrane-bound Gag in both assays, suggesting that Gag induces the coalescence of lipid rafts and TEMs. Substitutions in membrane binding motifs of Gag revealed that, while Gag membrane binding is necessary to induce coalescence of lipid rafts and TEMs, either acylation of Gag or binding of phosphatidylinositol-(4,5)-bisphosphate is sufficient. Finally, a Gag derivative that is defective in inducing membrane curvature appeared less able to induce lipid raft and TEM coalescence. A higher-resolution analysis of assembly sites by correlative fluorescence and scanning electron microscopy showed that coalescence of clustered lipid rafts and TEMs occurs predominantly at completed cell surface virus-like particles, whereas a transmembrane raft marker protein appeared to associate with punctate Gag fluorescence even in the absence of cell surface particles. Together, these results suggest that different membrane microdomain components are recruited in a stepwise manner during assembly.

  18. Gag Induces the Coalescence of Clustered Lipid Rafts and Tetraspanin-Enriched Microdomains at HIV-1 Assembly Sites on the Plasma Membrane

    Science.gov (United States)

    Hogue, Ian B.; Grover, Jonathan R.; Soheilian, Ferri; Nagashima, Kunio; Ono, Akira

    2011-01-01

    The HIV-1 structural protein Gag associates with two types of plasma membrane microdomains, lipid rafts and tetraspanin-enriched microdomains (TEMs), both of which have been proposed to be platforms for HIV-1 assembly. However, a variety of studies have demonstrated that lipid rafts and TEMs are distinct microdomains in the absence of HIV-1 infection. To measure the impact of Gag on microdomain behaviors, we took advantage of two assays: an antibody-mediated copatching assay and a Förster resonance energy transfer (FRET) assay that measures the clustering of microdomain markers in live cells without antibody-mediated patching. We found that lipid rafts and TEMs copatched and clustered to a greater extent in the presence of membrane-bound Gag in both assays, suggesting that Gag induces the coalescence of lipid rafts and TEMs. Substitutions in membrane binding motifs of Gag revealed that, while Gag membrane binding is necessary to induce coalescence of lipid rafts and TEMs, either acylation of Gag or binding of phosphatidylinositol-(4,5)-bisphosphate is sufficient. Finally, a Gag derivative that is defective in inducing membrane curvature appeared less able to induce lipid raft and TEM coalescence. A higher-resolution analysis of assembly sites by correlative fluorescence and scanning electron microscopy showed that coalescence of clustered lipid rafts and TEMs occurs predominately at completed cell surface virus-like particles, whereas a transmembrane raft marker protein appeared to associate with punctate Gag fluorescence even in the absence of cell surface particles. Together, these results suggest that different membrane microdomain components are recruited in a stepwise manner during assembly. PMID:21813604

  19. Outcome of organs procured from donors on extracorporeal membrane oxygenation support: an analysis of kidney and liver allograft data.

    Science.gov (United States)

    Carter, Timothy; Bodzin, Adam S; Hirose, Hitoshi; West, Sharon; Hasz, Richard; Maley, Warren R; Cavarocchi, Nicholas C

    2014-07-01

    Extracorporeal membrane oxygenation has become rescue therapy for adults with overwhelming cardiac and/or respiratory failure. Not all patients are saved, creating a new cohort of potential organ donors. This study examines the outcomes of liver and kidney allografts procured from donors on extracorporeal membrane oxygenation (ECMO). A retrospective review was conducted through the local organ procurement organization. Donors on ECMO prior to notification were classified into donation after brain death (DBD) and donation after cardiac death (DCD). We compared short-term outcome data against published standards. Between 1995 and 2012, 97 organs were procured from 41 donors supported on ECMO. There were 68 kidneys donated, 51 were transplanted and 17 discarded. Excluding extended criteria donors, 29 DBD and 13 DCD kidneys were transplanted from donors supported on ECMO. Delayed graft function occurred in 34% of DBD kidneys and 38% of DCD kidneys. Kidney allograft survival at one yr was 93%. Twenty-four livers were procured, nine discarded, and 15 transplanted. Ninety-three percent of liver transplant recipients were alive with graft function at one yr. Donation after brain death kidneys procured from donors on ECMO perform similarly to non-ECMO organs with regard to delayed graft function (DGF), one-yr graft survival and function. Livers from ECMO donors have a higher discard rate than non-ECMO donors, but function similarly at six months and one yr. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Use of Extracorporeal Membrane Oxygenation in a Fulminant Course of Amniotic Fluid Embolism Syndrome Immediately after Cesarean Delivery

    Directory of Open Access Journals (Sweden)

    Jae Ha Lee

    2016-08-01

    Full Text Available Amniotic fluid embolism is rare but is one of the most catastrophic complications in the peripartum period. This syndrome is caused by a maternal anaphylactic reaction to the introduction of fetal material into the pulmonary circulation. When amniotic fluid embolism is suspected, the immediate application of extracorporeal mechanical circulatory support such as veno-arterial extracorporeal membrane oxygenation (ECMO or cardiopulmonary bypass should be considered. Without the application of extracorporeal mechanical circulatory support, medical supportive care might not be sufficient to maintain cardiopulmonary stabilization in severe cases of amniotic fluid embolism. In this report, we present the case of a 36-year-old pregnant woman who developed an amniotic fluid embolism immediately after a cesarean section. Her catastrophic event started with the sudden onset of severe hypoxia, followed by circulatory collapse within 8 minutes. The veno-arterial mode of extracorporeal membrane oxygenation was initiated immediately. She was successfully resuscitated but with impaired cognitive function. Thus, urgent ECMO should be considered when amniotic fluid embolism syndrome is suspected in patients presenting acute cardiopulmonary collapse.

  1. Deep defect levels in standard and oxygen enriched silicon detectors before and after **6**0Co-gamma-irradiation

    CERN Document Server

    Stahl, J; Lindström, G; Pintilie, I

    2003-01-01

    Capacitance Deep Level Transient Spectroscopy (C-DLTS) measurements have been performed on standard and oxygen-doped silicon detectors manufactured from high-resistivity n-type float zone material with left angle bracket 111 right angle bracket and left angle bracket 100 right angle bracket orientation. Three different oxygen concentrations were achieved by the so-called diffusion oxygenated float zone (DOFZ) process initiated by the CERN-RD48 (ROSE) collaboration. Before the irradiation a material characterization has been performed. In contrast to radiation damage by neutrons or high- energy charged hadrons, were the bulk damage is dominated by a mixture of clusters and point defects, the bulk damage caused by **6**0Co-gamma-radiation is only due to the introduction of point defects. The dominant electrically active defects which have been detected after **6**0Co-gamma-irradiation by C-DLTS are the electron traps VO//i, C//iC//s, V//2( = /-), V //2(-/0) and the hole trap C//i O//i. The main difference betwe...

  2. Perovskite-related oxide materials for oxygen-permeable electrochemical membrans

    OpenAIRE

    Naumovich, E. N.; Yaremchenko, A. A.; Viskup, A. P.; Kharton, V. V.

    2003-01-01

    This brief review is focused on the studies of mixed ionic-electronic conductors on the basis of lanthanum gallate doped with transition metal cations in the В sublattice. The substitution of gallium with iron, cobalt or nickel results in greater electronic conductivity, simultaneously keeping high level of the oxy-gen ionic transport. In particular, La0 90Sr0 10Ga0 65Ni0 20Mg0 1503d perovskite exhib-its attractive oxygen permeability, which is quite similar to that of La2Ni04- and (...

  3. A safe procedure for connecting a continuous renal replacement therapy device into an extracorporeal membrane oxygenation circuit.

    Science.gov (United States)

    Suga, Natsumi; Matsumura, Yosuke; Abe, Ryuzo; Hattori, Noriyuki; Nakada, Taka-Aki; Oda, Shigeto

    2017-06-01

    Patients receiving extracorporeal membrane oxygenation (ECMO) often require continuous renal replacement therapy (CRRT). The intra-circuit pressure of adult ECMO usually deviates from the physiological range. We investigated the use of CRRT connected to an ECMO circuit with physiological intra-circuit pressures (0-150 mmHg, defined as the "safety range") using an in vitro experiment involving a water-filled ECMO circuit. The intra-circuit pressure pre-pump, post-pump, and post-oxygenator were measured while varying the height of the pump or ECMO flow. The bypass conduit pressure and distance from the post-oxygenator port were measured to find the "safety point", where the bypass pressure remained within the safety range. Both drainage and return limbs of the CRRT machine were connected to the safety point and the inlet and outlet pressures of the hemofilter were recorded while varying the ECMO and CRRT flow. The pre-pump pressure only remained within the safety range for heights >75 cm (ECMO flow = 4 L/min) or ECMO flow machine safely under physiological pressures in adult patients receiving ECMO.

  4. Growth of the obligate anaerobe Desulfovibrio vulgaris Hildenborough under continuous low oxygen concentration sparging: impact of the membrane-bound oxygen reductases.

    Science.gov (United States)

    Ramel, Fanny; Brasseur, Gael; Pieulle, Laetitia; Valette, Odile; Hirschler-Réa, Agnès; Fardeau, Marie Laure; Dolla, Alain

    2015-01-01

    Although obligate anaerobe, the sulfate-reducing bacterium Desulfovibrio vulgaris Hildenborough (DvH) exhibits high aerotolerance that involves several enzymatic systems, including two membrane-bound oxygen reductases, a bd-quinol oxidase and a cc(b/o)o3 cytochrome oxidase. Effect of constant low oxygen concentration on growth and morphology of the wild-type, single (Δbd, Δcox) and double deletion (Δcoxbd) mutant strains of the genes encoding these oxygen reductases was studied. When both wild-type and deletion mutant strains were cultured in lactate/sulfate medium under constant 0.02% O2 sparging, they were able to grow but the final biomasses and the growth yield were lower than that obtained under anaerobic conditions. At the end of the growth, lactate was not completely consumed and when conditions were then switched to anaerobic, growth resumed. Time-lapse microscopy revealed that a large majority of the cells were then able to divide (over 97%) but the time to recover a complete division event was longer for single deletion mutant Δbd than for the three other strains. Determination of the molar growth yields on lactate suggested that a part of the energy gained from lactate oxidation was derived toward cells protection/repairing against oxidative conditions rather than biosynthesis, and that this part was higher in the single deletion mutant Δbd and, to a lesser extent, Δcox strains. Our data show that when DvH encounters oxidative conditions, it is able to stop growing and to rapidly resume growing when conditions are switched to anaerobic, suggesting that it enters active dormancy sate under oxidative conditions. We propose that the pyruvate-ferredoxin oxidoreductase (PFOR) plays a central role in this phenomenon by reversibly switching from an oxidative-sensitive fully active state to an oxidative-insensitive inactive state. The oxygen reductases, and especially the bd-quinol oxidase, would have a crucial function by maintaining reducing conditions

  5. Growth of the obligate anaerobe Desulfovibrio vulgaris Hildenborough under continuous low oxygen concentration sparging: impact of the membrane-bound oxygen reductases.

    Directory of Open Access Journals (Sweden)

    Fanny Ramel

    Full Text Available Although obligate anaerobe, the sulfate-reducing bacterium Desulfovibrio vulgaris Hildenborough (DvH exhibits high aerotolerance that involves several enzymatic systems, including two membrane-bound oxygen reductases, a bd-quinol oxidase and a cc(b/oo3 cytochrome oxidase. Effect of constant low oxygen concentration on growth and morphology of the wild-type, single (Δbd, Δcox and double deletion (Δcoxbd mutant strains of the genes encoding these oxygen reductases was studied. When both wild-type and deletion mutant strains were cultured in lactate/sulfate medium under constant 0.02% O2 sparging, they were able to grow but the final biomasses and the growth yield were lower than that obtained under anaerobic conditions. At the end of the growth, lactate was not completely consumed and when conditions were then switched to anaerobic, growth resumed. Time-lapse microscopy revealed that a large majority of the cells were then able to divide (over 97% but the time to recover a complete division event was longer for single deletion mutant Δbd than for the three other strains. Determination of the molar growth yields on lactate suggested that a part of the energy gained from lactate oxidation was derived toward cells protection/repairing against oxidative conditions rather than biosynthesis, and that this part was higher in the single deletion mutant Δbd and, to a lesser extent, Δcox strains. Our data show that when DvH encounters oxidative conditions, it is able to stop growing and to rapidly resume growing when conditions are switched to anaerobic, suggesting that it enters active dormancy sate under oxidative conditions. We propose that the pyruvate-ferredoxin oxidoreductase (PFOR plays a central role in this phenomenon by reversibly switching from an oxidative-sensitive fully active state to an oxidative-insensitive inactive state. The oxygen reductases, and especially the bd-quinol oxidase, would have a crucial function by maintaining

  6. Development of Dual-Phase Oxygen Transport Membranes for Carbon Capture Processes

    DEFF Research Database (Denmark)

    Pirou, Stéven

    Fossil fuel based power plants and industrial production of cement and steel are major sources of anthropogenic CO2 emissions. One of the most promising approaches to capture and store CO2 from such large point sources is the oxy-fuel combustion route, where pure oxygen instead of air is used...

  7. High performance electrode for electrochemical oxygen generator cell based on solid electrolyte ion transport membrane

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Wei; Shao, Zongping; Ran, Ran; Chen, Zhihao; Zeng, Pingying; Gu, Hongxia; Jin, Wanqin; Xu, Nanping [College of Chemistry and Chemical Engineering, Nanjing University of Technology, No. 5 Xin Mofan Road, Nanjing 210009, JiangSu (China)

    2007-06-30

    A double-layer composite electrode based on Ba{sub 0.5}Sr{sub 0.5}Co{sub 0.8}Fe{sub 0.2}O{sub 3-{delta}} + Sm{sub 0.2}Ce{sub 0.8}O{sub 1.9} (BSCF + SDC) and BSCF + SDC + Ag was investigated to be a promising cathode and also anode for the electrochemical oxygen generator based on samaria doped ceria electrolyte. The Ag particles in the second layer were not only the current collector but also the improver for the oxygen adsorption at the electrode. a.c. impedance results indicated that the electrode polarization resistance, as low as 0.0058 {omega} cm{sup 2} was reached at 800 C under air. In oxygen generator cell performance test, the electrode resistance dropped to half of the value at zero current density under an applied current density of 2.34 A cm{sup -2} at 700 C, and on the same conditions the oxygen generator cell was continual working for more than 900 min with a Faradic efficiency of {proportional_to}100%. (author)

  8. Numerical simulation of physicochemical interactions between oxygen atom and phosphatidylcholine due to direct irradiation of atmospheric pressure nonequilibrium plasma to biological membrane with quantum mechanical molecular dynamics

    Science.gov (United States)

    Uchida, Satoshi; Yoshida, Taketo; Tochikubo, Fumiyoshi

    2017-10-01

    Plasma medicine is one of the most attractive applications using atmospheric pressure nonequilibrium plasma. With respect to direct contact of the discharge plasma with a biological membrane, reactive oxygen species play an important role in induction of medical effects. However, complicated interactions between the plasma radicals and membrane have not been understood well. In the present work, we simulated elemental processes at the first stage of physicochemical interactions between oxygen atom and phosphatidylcholine using the quantum mechanical molecular dynamics code in a general software AMBER. The change in the above processes was classified according to the incident energy of oxygen atom. At an energy of 1 eV, the abstraction of a hydrogen atom and recombination to phosphatidylcholine were simultaneously occurred in chemical attachment of incident oxygen atom. The exothermal energy of the reaction was about 80% of estimated one based on the bond energies of ethane. An oxygen atom over 10 eV separated phosphatidylcholine partially. The behaviour became increasingly similar to physical sputtering. The reaction probability of oxygen atom was remarkably high in comparison with that of hydrogen peroxide. These results suggest that we can uniformly estimate various physicochemical dynamics of reactive oxygen species against membrane lipids.

  9. Experimental study on the mechanism of SO2 emission and calcium-based desulfurization in the coal oxygen-enriched combustion

    International Nuclear Information System (INIS)

    Tian, Luning; Chen, Hanping; Yang, Haiping; Wang, Xianhua; Zhang, Shihong

    2010-01-01

    Full text: The emission of SO 2 , CO 2 brings serious harm to the ecological environment, human health and the global climate change. The largest source of SO 2 , CO 2 is the combustion of fossil fuels for power generation. So developing the new technology for controlling pollutants emissions from coal combustion was imperative. Oxygen-enriched combustion technology is such a new technology which can realize CO 2 zero emission, enhance the combustion efficiency and reduce pollutants emission. Due to the high concentration of CO 2 , it has many different aspects in the SO 2 emission and calcium-based desulfurization compare with the conventional combustion. In this article, experiments have been done to investigate the behavior and mechanism of SO 2 emissions and removal in oxygen-enriched combustion. First, in TGA and fixed bed reactor, the SO 2 emission characteristics were investigated under various bed temperature, particle size and O 2 / CO 2 concentration. It was observed that SO 2 released faster and the emission peak was higher than air atmosphere. SO 2 emission concentration increased with the reaction temperature increasing. Simultaneously, the mechanism of SO 2 emission was obtained by analyzing the sulfur compounds in the gas products and solid products in different reaction times. Then, the impacts of reaction temperature, particle size, O 2 / CO 2 concentration and SO 2 concentration etc. on the efficiency of SO 2 removal were analyzed. The phase analysis, pore diameter distribution and microstructure of the solid product were investigated. The experimental results showed that the sulphur capture takes place by direct sulphation reaction at high CO 2 concentration which attributes to light sinter, better porous structure, higher optimal desulfurization temperature and high desulfurization efficiency of calcium-based sorbent. (author)

  10. Optimisation of oxygen ion transport in materials for ceramic membrane devices.

    Science.gov (United States)

    Kilner, J A

    2007-01-01

    Oxygen transport in ceramic oxide materials has received much attention over the past few decades. Much of this interest has stemmed from the desire to construct high temperature electrochemical devices for energy conversion, an example being the solid oxide fuel cell. In order to achieve high performance for these devices, insights are needed in how to achieve optimum performance from the functional components such as the electrolytes and electrodes. This includes the optimisation of oxygen transport through the crystal lattice of electrode and electrolyte materials and across the homogeneous (grain boundary) and heterogeneous interfaces that exist in real devices. Strategies are discussed for the optimisation of these quantities and current problems in the characterisation of interfacial transport are explored.

  11. Molten salt synthesis of nitrogen and oxygen enriched hierarchically porous carbons derived from biomass via rapid microwave carbonization for high voltage supercapacitors

    Science.gov (United States)

    Cheng, Yinfeng; Li, Baoqiang; Huang, Yanjuan; Wang, Yaming; Chen, Junchen; Wei, Daqing; Feng, Yujie; Jia, Dechang; Zhou, Yu

    2018-05-01

    Nitrogen and oxygen enriched hierarchically porous carbons (NOHPCs) derived from biomass have been successfully prepared by rapid microwave carbonization coupled with molten salt synthesis method in only 4 min. ZnCl2 plays important roles as microwave absorber, chemical activation agent and porogen in this process. NOHPC-1:10 sample possesses the maximum specific surface area of 1899 m2 g-1 with a pore volume of 1.16 cm3 g-1 and mesopore ratio of 70%, as well as nitrogen content of 5.30 wt% and oxygen content of 14.12 wt%. When evaluated as an electrode in a three-electrode system with 6 M KOH electrolyte, the material exhibits a high specific capacitance of 276 F g-1 at 0.2 A g-1, with a good rate capability of 90.9% retention at 10 A g-1. More importantly, the symmetric supercapacitor based on NOHPC-1:10 in 1 M Na2SO4 electrolyte exhibits a high energy density of 13.9 Wh kg-1 at a power density of 120 W kg-1 in a wide voltage window of 0-1.6 V, an excellent cycling stability with 95% of capacitance retention after 10,000 cycles. Our strategy provides a facile and rapid way for the preparation of advanced carbon materials derived from biomass towards energy storage applications.

  12. Improved wound management by regulated negative pressure-assisted wound therapy and regulated, oxygen- enriched negative pressure-assisted wound therapy through basic science research and clinical assessment

    Directory of Open Access Journals (Sweden)

    Moris Topaz

    2012-01-01

    Full Text Available Regulated negative pressure-assisted wound therapy (RNPT should be regarded as a state-of-the-art technology in wound treatment and the most important physical, nonpharmaceutical, platform technology developed and applied for wound healing in the last two decades. RNPT systems maintain the treated wound′s environment as a semi-closed, semi-isolated system applying external physical stimulations to the wound, leading to biological and biochemical effects, with the potential to substantially influence wound-host interactions, and when properly applied may enhance wound healing. RNPT is a simple, safe, and affordable tool that can be utilized in a wide range of acute and chronic conditions, with reduced need for complicated surgical procedures, and antibiotic treatment. This technology has been shown to be effective and safe, saving limbs and lives on a global scale. Regulated, oxygen-enriched negative pressure-assisted wound therapy (RO-NPT is an innovative technology, whereby supplemental oxygen is concurrently administered with RNPT for their synergistic effect on treatment and prophylaxis of anaerobic wound infection and promotion of wound healing. Understanding the basic science, modes of operation and the associated risks of these technologies through their fundamental clinical mechanisms is the main objective of this review.

  13. Effect of membranes on oxygen transfer rate and consumption within a newly developed three-compartment bioartificial liver device: Advanced experimental and theoretical studies.

    Science.gov (United States)

    Hilal-Alnaqbi, Ali; Mourad, Abdel-Hamid I; Yousef, Basem F

    2014-01-01

    A mathematical model is developed to predict oxygen transfer in the fiber-in-fiber (FIF) bioartificial liver device. The model parameters are taken from the constructed and tested FIF modules. We extended the Krogh cylinder model by including one more zone for oxygen transfer. Cellular oxygen uptake was based on Michaelis-Menten kinetics. The effect of varying a number of important model parameters is investigated, including (1) oxygen partial pressure at the inlet, (2) the hydraulic permeability of compartment B (cell region), (3) the hydraulic permeability of the inner membrane, and (4) the oxygen diffusivity of the outer membrane. The mathematical model is validated by comparing its output against the experimentally acquired values of an oxygen transfer rate and the hydrostatic pressure drop. Three governing simultaneous linear differential equations are derived to predict and validate the experimental measurements, e.g., the flow rate and the hydrostatic pressure drop. The model output simulated the experimental measurements to a high degree of accuracy. The model predictions show that the cells in the annulus can be oxygenated well even at high cell density or at a low level of gas phase PG if the value of the oxygen diffusion coefficient Dm is 16 × 10(-5) . The mathematical model also shows that the performance of the FIF improves by increasing the permeability of polypropylene membrane (inner fiber). Moreover, the model predicted that 60% of plasma has access to the cells in the annulus within the first 10% of the FIF bioreactor axial length for a specific polypropylene membrane permeability and can reach 95% within the first 30% of its axial length. © 2013 International Union of Biochemistry and Molecular Biology, Inc.

  14. The use of alteplase for the resolution of an intravesical clot in a neonate receiving extracorporeal membrane oxygenation.

    Science.gov (United States)

    Olarte, J L; Glover, M L; Totapally, B R

    2001-01-01

    We present a case of the use of alteplase for the lysis of a large urinary bladder clot. A neonate presented with respiratory failure, secondary to a left diaphragmatic hernia necessitating the need for extracorporeal membrane oxygenation (ECMO) support. On day 3 of ECMO support, hematuria was noted, and a subsequent urinary bladder ultrasound revealed a significant urinary bladder clot. Alteplase (0.5-1 mg) was instilled into the urinary bladder via a 10 French Foley catheter (Sherwood Medical, St. Louis, MO). The catheter was clamped for 1 hour, followed by irrigation with normal saline. Multiple doses of alteplase were administered, resulting in complete resolution of the bladder clot. No adverse effects were attributed to the use of the intravesical alteplase. Alteplase seems to be safe and effective for the resolution of bladder clots, thereby potentially avoiding more invasive surgical procedures.

  15. Biomass characterization by dielectric monitoring of viability and oxygen uptake rate measurements in a novel membrane bioreactor.

    Science.gov (United States)

    Shariati, Farshid Pajoum; Heran, Marc; Sarrafzadeh, Mohammad Hossein; Mehrnia, Mohammad Reza; Sarzana, Gabriele; Ghommidh, Charles; Grasmick, Alain

    2013-07-01

    The application of permittivity and oxygen uptake rate (OUR) as biological process control parameters in a wastewater treatment system was evaluated. Experiments were carried out in a novel airlift oxidation ditch membrane bioreactor under different organic loading rates (OLR). Permittivity as representative of activated sludge viability was measured by a capacitive on-line sensor. OUR was also measured as a representative for respirometric activity. Results showed that the biomass concentration increases with OLR and all biomass related measurements and simulators such as MLSS, permittivity, OUR, ASM1 and ASM3 almost follow the same increasing trends. The viability of biomass decreased when the OLR was reduced from 5 to 4 kg COD m(-3)d(-1). During decreasing of OLR, biomass related parameters generally decreased but not in a similar manner. Also, protein concentration in the system during OLR decreasing changed inversely with the activated sludge viability. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Extra-corporeal membrane oxygenation in the management of 2009 influenza A (H1N1) refractory respiratory failure.

    LENUS (Irish Health Repository)

    Das, J P

    2012-02-01

    Rapidly progressive acute respiratory failure attributed to 2009 H1N1 influenza A infection has been reported worldwide-3. Refractory hypoxaemia despite conventional mechanical ventilation and lung protective strategies has resulted in the use a combination of rescue therapies, such as conservative fluid management, prone positioning, inhaled nitric oxide, high frequency oscillatory ventilation and extracorporeal membrane oxygenation (ECMO)4. ECMO allows for pulmonary or cardiopulmonary support as an adjunct to respiratory and cardiac failure, minimising ventilator-associated lung injury (VALI). This permits treatment of the underlying disease process, while concurrently allowing for recovery of the acute lung injury. This case documents a previously healthy twenty-two year old Asian male patient with confirmed pandemic (H 1N1) 2009 influenza A who was successfully managed with ECMO in the setting of severe refractory hypoxaemia and progressive hypercapnia.

  17. Extra-corporeal membrane oxygenation in the management of 2009 influenza A (H1N1) refractory respiratory failure.

    LENUS (Irish Health Repository)

    Das, J P

    2011-03-01

    Rapidly progressive acute respiratory failure attributed to 2009 H1N1 influenza A infection has been reported worldwide-3. Refractory hypoxaemia despite conventional mechanical ventilation and lung protective strategies has resulted in the use a combination of rescue therapies, such as conservative fluid management, prone positioning, inhaled nitric oxide, high frequency oscillatory ventilation and extracorporeal membrane oxygenation (ECMO)4. ECMO allows for pulmonary or cardiopulmonary support as an adjunct to respiratory and cardiac failure, minimising ventilator-associated lung injury (VALI). This permits treatment of the underlying disease process, while concurrently allowing for recovery of the acute lung injury. This case documents a previously healthy twenty-two year old Asian male patient with confirmed pandemic (H 1N1) 2009 influenza A who was successfully managed with ECMO in the setting of severe refractory hypoxaemia and progressive hypercapnia.

  18. Extracorporeal Membrane Oxygenation for the Support of a Potential Organ Donor with a Fatal Brain Injury before Brain Death Determination

    Directory of Open Access Journals (Sweden)

    Sung Wook Chang

    2016-05-01

    Full Text Available The shortage of available organ donors is a significant problem and various efforts have been made to avoid the loss of organ donors. Among these, extracorporeal membrane oxygenation (ECMO has been introduced to help support and manage potential donors. Many traumatic brain injury patients have healthy organs that might be eligible for donation for transplantation. However, the condition of a donor with a fatal brain injury may rapidly deteriorate prior to brain death determination; this frequently results in the loss of eligible donors. Here, we report the use of venoarterial ECMO to support a potential donor with a fatal brain injury before brain death determination, and thereby preserve donor organs. The patient successfully donated his liver and kidneys after brain death determination.

  19. Venovenous Extracorporeal Membrane Oxygenation in an Adult Patient With Prader-Willi Syndrome: A Nutrition Case Report.

    Science.gov (United States)

    Pelekhaty, Stacy; Menaker, Jay

    2018-03-12

    Prader-Willi Syndrome (PWS) is a genetic condition that results in a constellation of symptoms and typically results in hyperphagia and obesity in adulthood. Critically ill adults with PWS present a unique challenge to the nutrition professional, particularly when they require support modalities such as extracorporeal membrane oxygenation (ECMO). The purpose of this case study is to review the nutrition care of a critically ill adult patient with PWS who required venovenous ECMO. The patient was successfully managed with a hypocaloric, high-protein approach, which did not result in the diagnosis of malnutrition during his hospitalization. The patient was ultimately transitioned off extracorporeal life support and discharged to a rehabilitation facility. © 2018 American Society for Parenteral and Enteral Nutrition.

  20. A polygeneration from a dual-gas partial catalytic oxidation coupling with an oxygen-permeable membrane reactor

    International Nuclear Information System (INIS)

    Hao, Yanhong; Huang, Yi; Gong, Minhui; Li, Wenying; Feng, Jie; Yi, Qun

    2015-01-01

    Highlights: • A new polygeneration system (PL-PCO-OPMR) to DME/methanol/power is proposed. • Exergeo-economic analysis is adopted to disclose the performance of systems. • Key technological conditions and parameters for PL-PCO-OPMR are optimized. • PL-PCO-OPMR shows high energy efficiency and low CO_2 emission. • PL-PCO-OPMR is an attractive way for high efficient and clean use of COG and CGG. - Abstract: Polygeneration system, typically involving chemicals/fuels and electricity co-production, is a promising technology for the sustainable development of energy and environment. In this study, a new polygeneration system based on coal and coke oven gas (COG) inputs for co-production of dimethyl ether (DME)/methanol and electricity is proposed. In the new system, an appropriate syngas for the synthesis of DME is from coal gasified gas (CGG) reforming of COG coupled with an oxygen-permeable membrane reactor, in which both COG and CGG reforming process and fuel combustion process are incorporated, which reduces exergy destruction in the whole reforming process. In order to obtain the best performance of CO_2 reduction, energy saving and economic benefit, the key operation parameters of the proposed process are analyzed and optimized. The new system is compared with the process based on CH_4/CO_2 dry reforming, in terms of exergy efficiency, exergy cost and CO_2 emissions. Through the new system, the exergy efficiency can be increased by 7.8%, the exergy cost can be reduced by 0.88 USD/GJ and the CO_2 emission can be reduced by 0.023 kg/MJ. These results suggest that the polygeneration system from CGG and COG partial catalytic oxidation coupling with an oxygen-permeable membrane reactor (PL-PCO-OPMR) would be a more attractive way for highly efficient and clean use of CGG and COG.

  1. Oxygen toxicity

    Directory of Open Access Journals (Sweden)

    C. A. van der Westhuizen

    1990-07-01

    Full Text Available Oxygen has been discovered about 200 years ago. Since then the vital physiological involvement of oxygen in various biologi­cal processes, mainly energy production, has been established. However, in the body molecular oxygen can be converted to toxic oxygen metabolites such as superoxide anion, hydrogen peroxide, the hydroxyl radical and singlet oxygen. These toxic metabolites are produced mainly in the mitochondria, plasma membranes and endoplasmic reticulum.

  2. Oxygen- and hydrogen-permeation measurements on-mixed conducting SrFeCo{sub 0.5}O{sub y} ceramic membrane material

    Energy Technology Data Exchange (ETDEWEB)

    Serra, E.; Casagrande, E.; La Barbera, A. [ENEA UTS MAT, CR Casaccia, 00060 S.M. di Galeria, Roma (Italy); Alvisi, M. [ENEA UTS MAT, CR Brindisi, 72100 Brindisi (Italy); Bezzi, G.; Mingazzini, C. [ENEA UTS MAT, CR Faenza, 48018 Faenza (Italy)

    2008-02-15

    The SrFeCo{sub 0.5}O{sub y} system combines high electronic/ionic conductivity with appreciable oxygen permeability at elevated temperatures. This system has potential use in high-temperature electrochemical applications such as solid oxide fuel cells, batteries, sensors, and oxygen separation membranes. Dense ceramic membranes of SrFeCo{sub 0.5}O{sub y} are prepared by pressing a ceramic powder prepared by using a sol-gel combustion technique. Oxygen and hydrogen permeation at high temperature on this material are studied. Measurements are conducted using a time-dependent permeation method at the temperature in the range of 1073-1273 K with oxygen- and hydrogen-driving pressures in the range (3 x 10{sup 2})-(1 x 10{sup 5}) Pa (300-1000 mbar). The maximum oxygen-permeated flux at 1273 K is 6.5 x 10{sup -3} mol m{sup -2} s{sup -1}. The activation energies for the O{sub 2}-permeation fluxes and diffusivities are 240 and 194 kJ/mol, respectively. Due to the high fragility, the high temperature for the measurements and the high oxygen permeation through such material, a special membrane holder, and compression sealing system have been designed and realized for the permeation apparatus. (author)

  3. Interfacial microstructure and shear strength of reactive air brazed oxygen transport membrane ceramic-metal alloy joints

    Science.gov (United States)

    FR, Wahid Muhamad; Yoon, Dang-Hyok; Raju, Kati; Kim, Seyoung; Song, Kwang-sup; Yu, Ji Haeng

    2018-01-01

    To fabricate a multi-layered structure for maximizing oxygen production, oxygen transport membrane (OTM) ceramics need to be joined or sealed hermetically metal supports for interfacing with the peripheral components of the system. Therefore, in this study, Ag-10 wt% CuO was evaluated as an effective filler material for the reactive air brazing of dense Ce0.9Gd0.1O2-δ-La0.7Sr0.3MnO3±δ (GDC-LSM) OTM ceramics. Thermal decomposition in air and wetting behavior of the braze filler was performed. Reactive air brazing was performed at 1050 °C for 30 min in air to join GDC-LSM with four different commercially available high temperature-resistant metal alloys, such as Crofer 22 APU, Inconel 600, Fecralloy, and AISI 310S. The microstructure and elemental distribution of the ceramic-ceramic and ceramic-metal interfaces were examined from polished cross-sections. The mechanical shear strength at room temperature for the as-brazed and isothermally aged (800 °C for 24 h) joints of all the samples was compared. The results showed that the strength of the ceramic-ceramic joints was decreased marginally by aging; however, in the case of metal-ceramic joints, different decreases in strengths were observed according to the metal alloy used, which was explained based on the formation of different oxide layers at the interfaces.

  4. Novel Combination of Impella and Extra Corporeal Membrane Oxygenation as a Bridge to Full Recovery in Fulminant Myocarditis

    Directory of Open Access Journals (Sweden)

    Sachin Narain

    2012-01-01

    Full Text Available A 31-year-old male was transferred to our hospital with severe heart failure due to viral myocarditis. He progressed to multiorgan failure requiring intubation and maximal doses of multiple vasopressors. Circulatory support was provided with an Impella device as a bridge to an extracorporeal membrane oxygenation (ECMO system. On full mechanical cardiovascular support, the patient's hemodynamic status improved and ECMO and Impella were explanted after 48 hours. Three days later, he was extubated and continued on to a full recovery. There are no specific therapies for fulminant myocarditis but first-line treatment is supportive care. ECMO is commonly used in patients with severe heart failure. In severe systolic dysfunction, left ventricular decompression is required to reduce myocardial wall stress, decrease myocardial oxygen requirements, and enhance the chances of recovery. The Impella, an active support system, is less invasive than classical decompressive techniques and is associated with lower requirements for blood products with fewer thromboembolic complications. This is the only case reported of the contemporary use of Impella and ECMO as a bridge to full recovery in an adult with myocarditis. It also presents a novel use of the Impella device in decompressing the left ventricle of an adult patient on ECMO.

  5. Catalytic combustion of the retentate gas from a CO2/H2 separation membrane reactor for further CO2 enrichment and energy recovery

    International Nuclear Information System (INIS)

    Hwang, Kyung-Ran; Park, Jin-Woo; Lee, Sung-Wook; Hong, Sungkook; Lee, Chun-Boo; Oh, Duck-Kyu; Jin, Min-Ho; Lee, Dong-Wook; Park, Jong-Soo

    2015-01-01

    The CCR (catalytic combustion reaction) of the retentate gas, consisting of 90% CO 2 and 10% H 2 obtained from a CO 2 /H 2 separation membrane reactor, was investigated using a porous Ni metal catalyst in order to recover energy and further enrich CO 2 . A disc-shaped porous Ni metal catalyst, namely Al[0.1]/Ni, was prepared by a simple method and a compact MCR (micro-channel reactor) equipped with a catalyst plate was designed for the CCR. CO 2 and H 2 concentrations of 98.68% and 0.46%, respectively, were achieved at an operating temperature of 400 °C, GHSV (gas-hourly space velocity) of 50,000 h −1 and a H 2 /O 2 ratio (R/O) of 2 in the unit module. In the case of the MCR, a sheet of the Ni metal catalyst was easily installed along with the other metal plates and the concentration of CO 2 in the retentate gas increased up to 96.7%. The differences in temperatures measured before and after the CCR were 31 °C at the product outlet and 19 °C at the N 2 outlet in the MCR. The disc-shaped porous metal catalyst and MCR configuration used in this study exhibit potential advantages, such as high thermal transfer resulting in improved energy recovery rate, simple catalyst preparation, and easy installation of the catalyst in the MCR. - Highlights: • The catalytic combustion of a retentate gas obtained from the H 2 /CO 2 separation membrane. • A disc-shaped porous nickel metal catalyst and a micro-channel reactor for catalytic hydrogen combustion. • CO 2 enrichment up to 98.68% at 400 °C, 50,000 h −1 and H 2 /O 2 ratio of 2.

  6. Optimization of the Pd-Fe-Mo Catalysts for Oxygen Reduction Reaction in Proton-Exchange Membrane Fuel Cells

    International Nuclear Information System (INIS)

    Lee, Yeayeon; Jang, Jeongseok; Lee, Jin Goo; Jeon, Ok Sung; Kim, Hyeong Su; Hwang, Ho Jung; Shul, Yong Gun

    2016-01-01

    Highlights: • Pd-Mo-Fe catalysts show high catalytic activity and stability for oxygen-reduction reactions in acid media. • The optimum compositions were 7.5:1.5:1.0 for Pd-Fe-Mo, and the optimum temperatures were 500 °C. • The Pd-Fe-Mo catalysts were successfully applied to the PEMFC cathode, showing ∼500 mA cm −1 at 0.6 V. • The lattice constant was strongly related to the activity and stability of the catalysts for oxygen-reduction reactions. - Abstract: Highly active and durable non-platinum catalysts for oxygen-reduction reaction (ORR) have been developed for energy conversion devices such as proton-exchange membrane fuel cells (PEMFCs). In this study, Pd-Fe-Mo catalyst is reported as a non-platinum catalyst for ORR. The atomic ratio and annealing temperatures are controlled on the catalysts to understand interplay between their physical and chemical properties and electrochemical activities. The Pd-Fe-Mo catalyst optimized with 7.5:1.5:1.0 of the atomic ratio and 500 °C of the annealing temperature shows 32.18 mA mg −1 PGM (PGM: platinum group metal) of the kinetic current density at 0.9 V for ORR, which is comparable to that of commercial Pt/C catalyst. The current density is degraded to 6.20 mA mg −1 PGM after 3000 cycling of cyclic voltammetry, but it is greatly enhanced value compared to other non-platinum catalysts. In actual application to PEMFCs, the 20% Pd-Fe-Mo catalyst supported on carbons exhibits a high performance of 506 mA cm −2 at 0.6 V. The results suggest that the Pd-Fe-Mo catalyst can be a good candidate for non-platinum ORR catalysts.

  7. Sodium Lauryl Sulfate Stimulates the Generation of Reactive Oxygen Species through Interactions with Cell Membranes.

    Science.gov (United States)

    Mizutani, Taeko; Mori, Ryota; Hirayama, Misaki; Sagawa, Yuki; Shimizu, Kenji; Okano, Yuri; Masaki, Hitoshi

    2016-12-01

    Sodium lauryl sulfate (SLS), a representative anionic surfactant, is well-known to induce rough skin following single or multiple topical applications. The mechanism by which SLS induces rough skin is thought to result from the disruption of skin moisture function consisting of NMF and epidermal lipids. However, a recent study demonstrated that topically applied SLS easily penetrates into the living cell layers of the epidermis, which suggests that physiological alterations of keratinocytes might cause the SLS-induced rough skin. This study was conducted to clarify the effects of SLS on keratinocytes to demonstrate the contribution of SLS to the induction of rough skin. In addition, the potentials of other widely used anionic surfactants to induce rough skin were evaluated. HaCaT keratinocytes treated with SLS had increased levels of intracellular ROS and IL-1α secretion. Application of SLS on the surface of a reconstructed epidermal equivalent also showed the increased generation of ROS. Further, SLS-treated cells showed an increase of intracellular calpain activity associated with the increase of intracellular Ca 2+ concentration. The increase of intracellular ROS was abolished by the addition of BAPTA-AM, a specific chelator of Ca 2+ . In addition, IL-1α also stimulated ROS generation by HaCaT keratinocytes. An ESR spin-labeling study demonstrated that SLS increased the fluidity of membranes of liposomes and cells. Together, those results indicate that SLS initially interacts with cell membranes, which results in the elevation of intracellular Ca 2+ influx. Ca 2+ stimulates the secretion of IL-1α due to the activation of calpain, and also increases ROS generation. IL-1α also stimulates ROS generation by HaCaT keratinocytes. We conclude from these results that the elevation of intracellular ROS levels is one of the causes of SLS-induced rough skin. Finally, among the other anionic surfactants tested, sodium lauryl phosphate has less potential to induce rough

  8. Formation of chondrules in a moderately high dust enriched disk: Evidence from oxygen isotopes of chondrules from the Kaba CV3 chondrite

    Science.gov (United States)

    Hertwig, Andreas T.; Defouilloy, Céline; Kita, Noriko T.

    2018-03-01

    Oxygen three-isotope analysis by secondary ion mass spectrometry of chondrule olivine and pyroxene in combination with electron microprobe analysis were carried out to investigate 24 FeO-poor (type I) and 2 FeO-rich (type II) chondrules from the Kaba (CV) chondrite. The Mg#'s of olivine and pyroxene in individual chondrules are uniform, which confirms that Kaba is one of the least thermally metamorphosed CV3 chondrites. The majority of chondrules in Kaba contain olivine and pyroxene that show indistinguishable Δ17O values (= δ17O - 0.52 × δ18O) within analytical uncertainties, as revealed by multiple spot analyses of individual chondrules. One third of chondrules contain olivine relict grains that are either 16O-rich or 16O-poor relative to other indistinguishable olivine and/or pyroxene analyses in the same chondrules. Excluding those isotopically recognized relicts, the mean oxygen isotope ratios (δ18O, δ17O, and Δ17O) of individual chondrules are calculated, which are interpreted to represent those of the final chondrule melt. Most of these isotope ratios plot on or slightly below the primitive chondrule mineral (PCM) line on the oxygen three-isotope diagram, except for the pyroxene-rich type II chondrule that plots above the PCM and on the terrestrial fractionation line. The Δ17O values of type I chondrules range from ∼-8‰ to ∼-4‰; the pyroxene-rich type II chondrule yields ∼0‰, the olivine-rich type II chondrule ∼-2‰. In contrast to the ungrouped carbonaceous chondrite Acfer 094, the Yamato 81020 CO3, and the Allende CV3 chondrite, type I chondrules in Kaba only possess Δ17O values below -3‰ and a pronounced bimodal distribution of Δ17O values, as evident for those other chondrites, was not observed for Kaba. Investigation of the Mg#-Δ17O relationship revealed that Δ17O values tend to increase with decreasing Mg#'s, similar to those observed for CR chondrites though data from Kaba cluster at the high Mg# (>98) and the low Δ17O

  9. Effects of Glucomannan-Enriched, Aronia Juice-Based Supplement on Cellular Antioxidant Enzymes and Membrane Lipid Status in Subjects with Abdominal Obesity

    Directory of Open Access Journals (Sweden)

    Nevena Kardum

    2014-01-01

    Full Text Available The aim of this study was to analyze the effects of a 4-week-long consumption of glucomannan-enriched, aronia juice-based supplement on anthropometric parameters, membrane fatty acid profile, and status of antioxidant enzymes in erythrocytes obtained from postmenopausal women with abdominal obesity. Twenty women aged 45–65 with a mean body mass index (BMI of 36.1 ± 4.4 kg/m2 and waist circumference of 104.8 ± 10.1 cm were enrolled. Participants were instructed to consume 100 mL of supplement per day as part of their regular diet. A significant increase in the content of n-3 (P<0.05 polyunsaturated fatty acids in membrane phospholipids was observed, with a marked increase in the level of docosahexaenoic fatty acid (P<0.05. Accordingly, a decrease in the n-6 and n-3 fatty acids ratio was observed (P<0.05. The observed effects were accompanied with an increase in glutathione peroxidase activity (P<0.05. Values for BMI (P<0.001, waist circumference (P<0.001, and systolic blood pressure (P<0.05 were significantly lower after the intervention. The obtained results indicate a positive impact of tested supplement on cellular oxidative damage, blood pressure, and anthropometric indices of obesity.

  10. Oxygen permeation flux through 10Sc1YSZ-MnCo2O4 asymmetric membranes prepared by two-step sintering

    DEFF Research Database (Denmark)

    Pirou, Stéven; Gurauskis, Jonas; Gil, Vanesa

    2016-01-01

    Asymmetric membranes based on a dual phase composite consisting of (Y2O3)0.01(Sc2O3)0.10(ZrO2)0.89 (10Sc1YSZ) as ionic conductor and MnCo2O4 as electronic conductor were prepared and characterized with respect to sinterability, microstructure and oxygen transport properties. The composite membranes...... were prepared by tape casting, lamination and fired in a two-step sintering process. Microstructural analysis showed that a gastight thin membrane layer with the desired ratio of ionic/electronic conducting phases could be fabricated. Oxygen permeation fluxes across the 10SclYSZ/MnCo2O4 (70/30 vol......%) composite membrane were measured from 750 to 940 degrees C using air or pure oxygen as feed gases and N2 or CO2 as sweep gases. Fluxes up to 2.3 mlN min-1 cm-2 were obtained for the 7 μm thick membrane. A degradation test over 1730 h showed an initial degradation of 21% during the first 1100 h after which...

  11. Long-term operation of oxygen-limiting membrane bioreactor (MBR) for the development of simultaneous partial nitrification, anammox and denitrification (SNAD) process.

    Science.gov (United States)

    Zhao, Chuanqi; Wang, Gang; Xu, Xiaochen; Yang, Yuesuo; Yang, Fenglin

    2017-07-18

    In this study, an oxygen-limiting membrane bioreactor (MBR) with recirculation of biogas for relieving membrane fouling was successfully operated to realize the simultaneous partial nitrification, anammox and denitrification (SNAD) process. The MBR operation was considered effective in the long-term test with total nitrogen (TN) and chemical oxygen demand (COD) removal efficiencies of 94.86% and 98.91%, respectively. Membrane fouling was significantly alleviated due to the recirculation of biogas and the membrane had been cleaned four times with a normal filtration period of 52 days. The co-existence of ammonia-oxidizing bacteria (AOB), anammox and denitrifying bacteria in MBR was confirmed by scanning electron microscopy (SEM) and fluorescence in situ hybridizations (FISH) analysis. Furthermore, AOB were found close to the granule surface, while denitrifying bacteria and anammox were in the deeper layer of granules. Potential in excellent TN and COD removal, operational stability and sustainability, as well as in alleviating membrane fouling is expected by using this oxygen-limiting MBR.

  12. Overexpression of MicA induces production of OmpC-enriched outer membrane vesicles that protect against Salmonella challenge.

    Science.gov (United States)

    Choi, Hyun-Il; Kim, Moonjeong; Jeon, Jinseong; Han, Jin Kwan; Kim, Kwang-Sun

    2017-08-26

    Outer membrane vesicles (OMVs) derived from bacteria are promising candidates for subunit vaccines. Stresses that modulate the composition of outer membrane proteins (OMPs) are important for OMV synthesis. Small RNAs (sRNAs) expressed in response to stress regulate OMPs, although the mechanism underlying sRNA-mediated OMV biogenesis and its utility for developing vaccine platforms remains to be elucidated. Here, we characterized the role of a sRNA, MicA, which regulates OmpA, a major OMP involved in both production of OMVs and reactive immunity against Salmonella challenge. A Salmonella strain overexpressing MicA generated more OMVs than a control strain. In addition, OmpC was the major component of MicA-derived OMV proteins. MicA-derived OMVs induced Th1- and Th17-type immune responses in vitro and reduced Salmonella-mediated lethality in a mouse model. Thus, OmpA-regulatory sRNA-derived OMVs may facilitate production of Salmonella-protective vaccines. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Sensitive determination of trace mercury by UV-visible diffuse reflectance spectroscopy after complexation and membrane filtration-enrichment.

    Science.gov (United States)

    Yin, Changhai; Iqbal, Jibran; Hu, Huilian; Liu, Bingxiang; Zhang, Lei; Zhu, Bilin; Du, Yiping

    2012-09-30

    A simple, sensitive and selective solid phase reflectometry method is proposed for the determination of trace mercury in aqueous samples. The complexation reagent dithizone was firstly injected into the properly buffered solution with vigorous stirring, which started a simultaneous formation of nanoparticles suspension of dithizone and its complexation reaction with the mercury(II) ions to make Hg-dithizone nanoparticles. After a definite time, the mixture was filtered with membrane, and then quantified directly on the surface of the membrane by using integrating sphere accessory of the UV-visible spectrophotometer. The quantitative analysis was carried out at a wavelength of 485 nm since it yielded the largest difference in diffuse reflectance spectra before and after reaction with mercury(II).A good linear correlation in the range of 0.2-4.0 μg/L with a squared correlation coefficient (R(2)) of 0.9944 and a detection limit of 0.12 μg/L were obtained. The accuracy of the method was evaluated by the analysis of spiked mercury(II) concentrations determined using this method along with those determined by the atomic fluorescence mercury vapourmeter and the results obtained were in good agreement. The proposed method was applied to the determination of mercury in tap water and river water samples with the recovery in an acceptable range (95.7-105.3%). Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Avaliação de oxigenador de membrana infantil em ovinos Evaluation of infant membrane oxygenator in sheep

    Directory of Open Access Journals (Sweden)

    Renata Geron Finoti

    2008-09-01

    Full Text Available OBJETIVO: Analisar a segurança e a eficácia de um novo oxigenador de membrana denominado OXM -1500. MÉTODOS: No período de maio de 2005 a setembro de 2006, foram estudados seis ovinos da raça Santa Inês, sendo cinco machos e uma fêmea, com peso corpóreo médio de 14,1 (±5 kg, superfície corpórea de 0,6 (±0,2 m² e idade média de 3,8 (±1,5 meses. Todos foram submetidos a circulação extracorpórea (CEC com avaliação nos tempos 10, 30, 60, 120, 180 e 240 minutos, obtendo-se os valores de taxa de transferência de oxigênio (TTO2 e de taxa de transferência de gás carbônico (TTCO2, hemoglobina sérica (HBS e livre (HBL, plaquetometria, leucometria e taxa de transferência de calor. RESULTADOS: Houve adequadas TTO2 e TTCO2. A lesão da maioria dos elementos figurados do sangue foi insignificante, sem alterações dos níveis de HBS, HBL, plaquetas e o número de leucócitos diminuíram com o tempo. A troca de calor foi efetiva (p OBJECTIVE: To analyze the security and efficacy of a new membrane oxygenator, the so-called OXM - 1500. METHODS: From May 2005 to September 2006, six sheep of Santa Inês breed (five male and one female, respectively were studied. The average body weight was 14.1 (±5 kg, body surface 0.6 (±0.2 m² and a mean age 3.8 (±1.5 months. All of them were submitted to extracorporeal circulation (CEC with evaluation at 10, 30, 60, 120, 180 and 240 minutes. The following values were obtained: values of oxygen transference (TTO2 and carbon dioxide transference (TTCO2, haemoglobin (HBS and free haemoglobin (HBL, the score of platelets and of leucocytes, and heat transference rate. RESULTS: TTO2 and TTCO2 were adequate. Lesion of the majority formed blood elements was insignificant; there no modifications in HBS, HBL levels; platelets and leucocytes decreased over time. Heat exchange was effective (p < 0.05. CONCLUSIONS: The membrane OXM - 1500 infant oxygenator, tested in sheep, showed adequate oxygenation capacity

  15. Oxygen permeation in thin, dense Ce0.9Gd0.1O 1.95- membranes II. experimental determination

    DEFF Research Database (Denmark)

    Chatzichristodoulou, Christodoulos; Søgaard, Martin; Glasscock, Julie

    2011-01-01

    Thin (∼30 m), dense Ce0.9Gd0.1O1.95- (CGO10) membranes (5 5 cm2+) supported on a porous NiO/YSZ substrate were fabricated by tape casting, wet powder spraying and lamination. A La 0.58Sr0.4Co0.2Fe0.8O 3-δ/Ce0.9Gd0.1O1.95- (LSCF/CGO10) composite cathode was applied by screen printing. Oxygen...... compartment. The performance of the membrane was also investigated under varying CH 4 and H2O gas mixtures at 1106 K. The oxygen flux increased with decreasing steam to carbon ratio and was found to exceed 10 N mL min-1 cm-2 of O2 for steam to carbon ratios below 4:3. Post-test analysis of the tested membrane...

  16. [Determination of Trace Lead in Water by UV-Visible Diffuse Reflectance Spectroscopy Combined with Surfactant and Membrane Filtration-Enrichment].

    Science.gov (United States)

    Zhang, Xiao-fang; Zhu, Bi-lin; Li, Wei; Wang, Lei; Zhang, Lei; Wu, Ting; Du, Yi-ping

    2015-07-01

    In this paper, a method of determination of trace lead in water by UV-Visible diffuse reflectance spectroscopy combined with surfactant and membrane filtration enrichment was proposed. In the NH3 x H2O-NH4Cl buffer solution with pH 8.5, the lead(II) ion would react with dithizone to form the red complex under vigorous stirring, which is hydrophobic and can be enriched by the mixed cellulose ester membrane. In addition, the nonionic surfactant Polyoxyethylene lauryl ether (Brij-30) was added into the solution to improve the enrichment efficiency, then visible diffuse reflectance spectra of the membrane were measured directly after the membrane were naturally dried. We also optimized the reaction conditions which may affect the complexation reaction process, such as type of surfactants, the concentration of the surfactant, the reaction acidity, the concentration of dithizone as well as the reaction time. The research results show that under the optimum conditions, a good linear correlation between absorbance at 485 nm and concentration of lead in the range of 5.0-100.0 microg x L(-1) was obtained with a squared correlation coefficient (R2) of 0.9906, and the detection limit was estimated accordingly to be 2.88 microg x L(-1). To determine real water sample, the interference from some potential coexisting ions was also studied at the optimal conditions when the concentration of lead (II) ion standard solution was fixed to 20 microg x L(-1). The results indicate that the following ions cannot interfere in the determination of lead with the proposed method: 500 times of the K+, Na+, Ca2+, Mg2+, NH4+, NO3-, Cl-, CH3COO-, SO4(2-); 10 times of the Al3+ (using 10% NaF as a masking reagent to avoid the interference); 10 times of the Fe3+ (using 10% NaF and 10% sodium potassium tartrate as masking reagents); 10 times of Hg2+ or Zn2+ (using 10% NaSCN and 10% potassium sodium tartrate as masking reagents); the same amount of Cd2+, Cu2+. The proposed method was applied to the

  17. Chalcone inhibitors of the NorA efflux pump in Staphylococcus aureus whole cells and enriched everted membrane vesicles.

    Science.gov (United States)

    Holler, Jes Gitz; Slotved, Hans-Christian; Mølgaard, Per; Olsen, Carl Erik; Christensen, Søren Brøgger

    2012-07-15

    A library of 117 chalcones was screened for efflux pump inhibitory (EPI) activity against NorA mediated ethidium bromide efflux. Five of the chalcones (5-7, 9, and 10) were active and two chalcones (9 and 10) were equipotent to reserpine with IC(50)-values of 9.0 and 7.7 μM, respectively. Twenty chalcones were subsequently proved to be inhibitors of the NorA efflux pump in everted membrane vesicles. Compounds 5, 7, and 9 synergistically increased the effect of ciprofloxacin on Staphylococcus aureus. Our results suggest that chalcones might be developed into drugs for overcoming multidrug resistance based on efflux transporters of microorganisms. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Characterization of NaA Zeolite Oxygen Permeable Membrane on TiO2/α-Al2O3 Composite Support

    Directory of Open Access Journals (Sweden)

    Zhu Mengfu

    2016-01-01

    Full Text Available The NaA zeolite membrane was synthesized on the surface of TiO2/α-Al2O3 composite support with TiO2 as modifier of α-Al2O3 porous tubular ceramic membrane support by crystallization method. The structure characterization indicated that the TiO2 of the support surface could effectively improve the surface properties of the support. It didn’t affect the crystallization of NaA synthesis liquid and synthesis process of NaA zeolite membrane. There were no obvious defects between the crystal particles with size of approximate 6μm. The perfect and complete membrane with thickness of approximate 15μm combined closely with support to connection together by TiO2 modified. The oxygen permeability of the membrane on TiO2/α-Al2O3 composite support improves of 47% compared with that of α-Al2O3 support. So the process of TiO2 modifying the surface of α-Al2O3 support should increase the oxygen permeability of the NaA zeolite membrane.

  19. THz spectroscopy of the 29 cm{sup -1} oxygen vibrational line in natural silicon and isotopically enriched {sup 28}Si

    Energy Technology Data Exchange (ETDEWEB)

    Lassmann, Kurt; Dressel, Martin [1. Physikalisches Inst., Univ. Stuttgart (Germany); Gorshunov, Boris; Zhukova, E.S. [1. Physikalisches Inst., Univ. Stuttgart (Germany); A.M. Prokhorov Gen. Phys. Inst., RAS, Moscow (Russian Federation); Moscow Inst. Physics and Technology (Russian Federation); Korolev, P.S. [A.M. Prokhorov Gen. Phys. Inst., RAS, Moscow (Russian Federation); Lomonosov Moscow State Univ. (Russian Federation); Kalinsuhkin, V.P. [A.M. Prokhorov Gen. Phys. Inst., RAS, Moscow (Russian Federation); Abrosimov, N.V. [Leibniz Inst. Kristallzuechtung, Berlin (Germany); Sennikov, P.G. [Inst. Chem. High-Purity Substances, Nizhny Novgorod (Russian Federation); Pohl, H.J. [PTB, Braunschweig (Germany); Zakel, S. [VITCON-Projektconsult, Jena (Germany)

    2012-07-01

    Looking for a possible host-isotope effect on the low-energy two-dimensional motion of interstitial oxygen in silicon we have measured the resonance parameters of the lowest transition of the 30 cm{sup -1} band of the Si-O-Si complex in natural Si and in isotopically enriched {sup 28}Si at temperatures between 5 K and 22 K by means of coherent-source terahertz spectroscopy. At 5.5 K we obtain for the resonance maxima 29.24 {+-} 0.003 cm{sup -1} and 29.22 {+-} 0.003 cm{sup -1} and for the line widths 0.09 {+-} 0.01 cm{sup -1} and 0.11 {+-} 0.01 cm{sup -1} for {sup 28}Si and {sup nat}Si, respectively. Both lines can be fitted by single Lorentzians, so, no obvious isotopic structure or asymmetry of the line in {sup nat}Si due to the Si neighbors in the Si-O-Si complex is detected. We therefore conclude that down-shift and broadening of the {sup nat}Si-resonance is not due to the Si isotopes in the isolated Si-O-Si complex but to an average effect of the isotopically inhomogeneous lattice.

  20. Green synthesized silver nanoparticles destroy multidrug resistant bacteria via reactive oxygen species mediated membrane damage

    Directory of Open Access Journals (Sweden)

    Balaram Das

    2017-09-01

    Full Text Available The growing need of antimicrobial agent for novel therapies against multi-drug resistant bacteria has drawn researchers to green nanotechnology. Especially, eco-friendly biosynthesis of silver nanoparticles (Ag NPs has shown its interesting impact against bacterial infection in laboratory research. In this study, a simple method was developed to form Ag NPs at room temperature, bio-reduction of silver ions from silver nitrate salt by leaf extract from Ocimum gratissimum. The Ag NPs appear to be capped with plant proteins, but are otherwise highly crystalline and pure. The Ag NPs have a zeta potential of −15 mV, a hydrodynamic diameter of 31 nm with polydispersity index of 0.65, and dry sizes of 18 ± 3 nm and 16 ± 2 nm, based on scanning and transmission electron microscopy respectively. The minimum inhibitory concentration (MIC of the Ag NPs against a multi-drug resistant Escherichia coli was 4 μg/mL and the minimum bactericidal concentration (MBC was 8 μg/mL, while the MIC and MBC against a resistant strain of Staphylococcus aureus were slightly higher at 8 μg/mL and 16 μg/mL respectively. Further, the Ag NPs inhibited biofilm formation by both Escherichia coli and S. aureus at concentrations similar to the MIC for each strain. Treatment of E. coli and S. aureus with Ag NPs resulted in damage to the surface of the cells and the production of reactive oxygen species. Both mechanisms likely contribute to bacterial cell death. In summary, this new method appears promising for green biosynthesis of pure Ag NPs with potent antimicrobial activity.

  1. Oxygen permeability of transition metal-containing La(Sr,PrGa(MgO3-δ ceramic membranes

    Directory of Open Access Journals (Sweden)

    Frade, J. R.

    2004-08-01

    Full Text Available Acceptor-type doping of perovskite-type La1-xSrxGa0.80-yMgyM0.20O3-δ (x = 0-0.20, y = 0.15-0.20, M = Fe, Co, Ni leads to significant enhancement of ionic conductivity and oxygen permeability due to increasing oxygen vacancy concentration. The increase in strontium and magnesium content is accompanied, however, with increasing role of surface exchange kinetics as permeation-limiting factor. At temperatures below 1223 K, the oxygen permeation fluxes through La(SrGa(Mg,MO3-δ membranes with thickness less than 1.5 mm are predominantly limited by the exchange rates at membrane surface. The oxygen transport in transition metal-containing La(SrGa(MgO3-δ ceramics increase in the sequence Co El dopado aceptor de cerámicas tipo perovskita La1-xSrxGa0.80-yMgyM0.20O3-δ (x = 0-0.20, y = 0.15-0.20, M = Fe, Co, Ni da lugar a una mejora significativa de la conductividad iónica y de la permeabilidad al oxígeno debido al aumento de la concentración de vacantes de oxígeno. Sin embargo, el aumento de la cantidad de estroncio y magnesio viene acompañado de un aumento de la participación de las cinéticas de intercambio superficial como factor limitante de la permeabilidad. A temperaturas por debajo de 1223 K la permeabilidad al flujo de oxígeno a través de las membranas de La(SrGa(Mg,MO3-δ con espesor menor de 1.5 mm está limitado principalmente por las velocidades de intercambio en la superficie de la membrana. El transporte de oxígeno en las cerámicas La(SrGa(MgO3-δ que contienen M aumenta en la secuencia Co < Fe < Ni. La conductividad iónica en estas fases es, sin embargo, menor que en la de los compuestos La1-xSrxGa1-yMgyO3-δ. El mayor nivel de permeabilidad de oxígeno, comparable a la de las fases basadas en La(SrFe(CoO3 y La2NiO4, se observa para las membranas de La0.90Sr0.10Ga0.65Mg0.15Ni0.20O3-δ. Los coeficientes de dilatación térmica medios de las cerámicas La(SrGa(Mg,MO3-δ en aire son del orden de (11.6–18.4 × 10-6 K-1 a 373

  2. Differential Effects Of Octanoate And Heptanoate On Myocardial Metabolism During Extracorporeal Membrane Oxygenation In An Infant Swine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kajimoto, Masaki; Ledee, Dolena R.; Isern, Nancy G.; Olson, Aaron; Des Rosiers, Christine; Portman, Michael A.

    2015-10-01

    Background: Nutritional energy support during extracorporeal membrane oxygenation (ECMO) should promote successful myocardial adaptation and eventual weaning from the ECMO circuit. Fatty acids (FAs) are a major myocardial energy source, and medium-chain FAs (MCFAs) are easily taken up by cell and mitochondria without membrane transporters. Oddnumbered MCFAs supply carbons to the citric acid cycle (CAC) via anaplerotic propionyl-CoA as well as acetyl-CoA, the predominant betaoxidation product for even-numbered MCFA. Theoretically, this anaplerotic pathway enhances carbon entry into the CAC, and provides superior energy state and preservation of protein synthesis. We tested this hypothesis in an immature swine model undergoing ECMO. Methods: Fifteen male Yorkshire pigs (26-45 days old) with 8-hour ECMO were received either normal saline, heptanoate (odd-numbered MCFA) or octanoate (even-numbered MCFA) at 2.3 μmol/kg body wt/min as MCFAs systemically during ECMO (n = 5 per group). The 13-Carbon (13C)-labeled substrates ([2-13C]lactate, [5,6,7-13C3]heptanoate and [U-13C6]leucine) were systemically infused as metabolic markers for the final 60 minutes before left ventricular tissue extraction. Extracted tissues were analyzed for the 13C-labeled and absolute concentrations of metabolites by nuclear magnetic resonance and gas chromatography-mass spectrometry. Results: Octanoate produced markedly higher myocardial citrate concentration, and led to a higher [ATP]/[ADP] ratio compared with other http://mc.manuscriptcentral.com/jpen Journal of Parenteral and Enteral Nutrition For Peer Review groups. Unexpectedly, octanoate increased the flux of propionyl-CoA relative to acetyl-CoA into the CAC as well as heptanoate. MCFAs promoted increases in leucine oxidation, but were not associated with a difference in fractional protein synthesis rate. Conclusion: Octanoate provides energetic advantages to the heart over heptanoate, while preserving protein synthesis.

  3. A Case Report of Churg-Strauss Syndrome Presenting With Cardiogenic Shock Treated With Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Cui, Na; Su, Longxiang; Wang, Hao; Long, Yun; Pang, Cheng; Yang, Fei; Liu, Dawei

    2015-10-01

    Churg-Strauss Syndrome (CSS) complicated with cardiogenic shock is rare. Few case reports have described successful treatment of this rare disease. However, no one has reported on the application of mechanical life support with extracorporeal membrane oxygenation (ECMO) to treat this life-threatening disease.A 36-year-old female with limb numbness for >10 days, chest tightness for 2 days, and worsening dyspnea for 5 h presented in the emergency room. Vital signs showed a low blood pressure (104/60 mm Hg), increased heart rate (158 bpm), and respiration rate (28 bpm). Laboratory tests revealed that eosinophil was significantly increased (WBC: 34.46 × 10/L, neutrophil: 7.56 × 10/L[21.9%], eosinophil: 23.84 × 10/L[69.2%]), and serum myocardial enzymes was abnormal (CK 1049U/L, CKMB-mass 145.1 μg/L, cTnI 16.24 μg/L). Myocardial injury (tachycardia with ST elevation) and poor heart function (LVEF 31%) were found by electrocardiogram and transthoracic echocardiography. On the next day, cardiogenic shock had been developed as demonstrated by deteriorating the perfusion index.Churg-Strauss Syndrome with cardiogenic shock.A series of conservative therapy with drugs such as corticosteroids, anticoagulant, antiplatelet, nitrates, calcium antagonists, inotrope, and vasopressors were initiated on the day of admission. The treatment was ineffective and a cardiogenic shock developed on the next day. Thus, ECMO was initiated immediately to stabilize circulation and perfusion. At the same time, high-dose corticosteroids combined with immunosuppressive therapy were continuously used.Symptoms of cardiogenic shock were gradually improved after ECMO treatment. Elevated values of cardiac enzymes were decreased and the dose of vasoactive drugs was reduced. Extracorporeal membrane oxygenation was discontinued after 8 days, and the patient was eventually weaned off the ventilator. The patient was discharged after 40 days treatment.Once a CSS develops into a

  4. Safety and efficacy of distal perfusion catheterization to prevent limb ischemia after common femoral artery cannulation for extracorporeal membrane oxygenation

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Chang Ho; Seong, Nak Jong; Yoon, Chang Jin [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-06-15

    The extracorporeal membrane oxygenation (ECMO) cannula has the potential for obstructing flow to the lower limb, thus causing severe ischemia and possible limb loss. We evaluated the safety and clinical efficacy of percutaneous distal perfusion catheterization in preventing limb ischemia. Between March 2013 and February 2015, 28 patients with distal perfusion catheterization after ECMO were included in this retrospective study. The technical success was evaluated by Doppler ultrasound at the popliteal level after saline injection via distal perfusion catheter. Clinical success was assessed when at least one of the following conditions was met: restoration of continuous peripheral limb oximetry value or presence of distal arterial pulse on Doppler ultrasound evaluation or resolution of early ischemic sign after connecting the catheter with ECMO. Twenty-six patients with early ischemia were successfully cannulated with a distal perfusion catheter (92.8%). Clinical success was achieved in 12/28 (42.8%) patients; 8/10 (80.0%) patients with survival duration exceeding 7 days and 4/18 (22.2%) patients with survival duration less than 7 days, respectively. A percutaneous distal perfusion catheter placement was a feasible tool with safety and efficacy in preventing lower limb ischemia for patients with prolonged common femoral arterial cannulation for ECMO.

  5. Safety and efficacy of distal perfusion catheterization to prevent limb ischemia after common femoral artery cannulation for extracorporeal membrane oxygenation

    International Nuclear Information System (INIS)

    Jeon, Chang Ho; Seong, Nak Jong; Yoon, Chang Jin

    2016-01-01

    The extracorporeal membrane oxygenation (ECMO) cannula has the potential for obstructing flow to the lower limb, thus causing severe ischemia and possible limb loss. We evaluated the safety and clinical efficacy of percutaneous distal perfusion catheterization in preventing limb ischemia. Between March 2013 and February 2015, 28 patients with distal perfusion catheterization after ECMO were included in this retrospective study. The technical success was evaluated by Doppler ultrasound at the popliteal level after saline injection via distal perfusion catheter. Clinical success was assessed when at least one of the following conditions was met: restoration of continuous peripheral limb oximetry value or presence of distal arterial pulse on Doppler ultrasound evaluation or resolution of early ischemic sign after connecting the catheter with ECMO. Twenty-six patients with early ischemia were successfully cannulated with a distal perfusion catheter (92.8%). Clinical success was achieved in 12/28 (42.8%) patients; 8/10 (80.0%) patients with survival duration exceeding 7 days and 4/18 (22.2%) patients with survival duration less than 7 days, respectively. A percutaneous distal perfusion catheter placement was a feasible tool with safety and efficacy in preventing lower limb ischemia for patients with prolonged common femoral arterial cannulation for ECMO

  6. Identifying neonates at a very high risk for mortality among children with congenital diaphragmatic hernia managed with extracorporeal membrane oxygenation.

    Science.gov (United States)

    Haricharan, Ramanath N; Barnhart, Douglas C; Cheng, Hong; Delzell, Elizabeth

    2009-01-01

    The purpose of this study was to identify mortality risk factors in children with congenital diaphragmatic hernia (CDH) treated with extracorporeal membrane oxygenation (ECMO) and generate a prediction score for those at a very high risk for mortality. Data on first ECMO runs of all neonates with CDH, between January 1997 and June 2007, were obtained from the Extracorporeal Life Support Organization registry (N = 2678). The data were split into "training data (TD)" (n = 2006) and "validation data" (n = 672). The primary outcome analyzed was in-hospital mortality. Modified Poisson regression was used for analyses. Overall in-hospital mortality among 2678 neonates (males, 57%; median age at ECMO, 1 day) was 52%. The univariate and multivariable analyses were performed using TD. An empirically weighted mortality prediction score was generated with possible scores ranging from 0 to 35 points. Of 69 who scored 14 or higher in the TD, 62 died (positive predictive value [PPV], 90%), of 37 with 15 or higher, 35 died (PPV, 95%), of 23 with 16 or higher, 22 died (PPV, 96%). A cut-off point of 15 was chosen and was tested using the separate validation dataset. In validation data, the cut-off point 15 had a PPV of 96% (23 died of 24). Scoring 15 or higher on the prediction score identifies neonates with CDH at a very high risk for mortality among those managed with ECMO and could be used in surgical decision making and counseling.

  7. Management benefits and safety of computed tomography in patients undergoing extracorporeal membrane oxygenation therapy: experience of a single centre

    International Nuclear Information System (INIS)

    Jepson, S.L.; Harvey, C.; Entwisle, J.J.; Peek, G.J.

    2010-01-01

    Aim: To evaluate the benefits and logistical safety of computed tomography (CT) imaging in patients undergoing extracorporeal membrane oxygenation (ECMO) therapy in a single institution. Materials and methods: Over a period of 25 months, 134 patients (80 neonates, 19 children, and 35 adults) underwent ECMO therapy at this institution. The imaging of these patients was reviewed to identify patients who had undergone CT imaging whilst on ECMO. Patient notes were retrospectively reviewed. CT findings and subsequent decisions were analysed to assess the benefit of CT imaging. Complications arising due to the logistics of performing the scan were analysed to assess the safety of performing CT in ECMO patients. Results: Of 134 patients, 14 (10%) had a total of 15 CT examinations whilst undergoing ECMO therapy. Indications for CT included new neurology, increased respiratory demand, and increasing requirement for high ECMO flows. There were no major complications and two minor complications associated with the logistics of performing a CT examination on an ECMO patient. Significant findings resulted from 73.3% (11/15) of the CT examinations, and in all 15 examinations information was provided that was used in making further management decisions, including, in some cases, withdrawal of ECMO therapy. Conclusion: With an experienced team, CT imaging of patients on ECMO can be performed safely. CT provides valuable information for subsequent management of patients undergoing ECMO therapy.

  8. Modeling the performance of hydrogen-oxygen unitized regenerative proton exchange membrane fuel cells for energy storage

    Science.gov (United States)

    Guarnieri, Massimo; Alotto, Piergiorgio; Moro, Federico

    2015-11-01

    Thanks to the independent sizing of power and energy, hydrogen-based energy storage is one of the very few technologies capable of providing long operational times in addition to the other advantages offered by electrochemical energy storage, for example scalability, site versatility, and mobile service. The typical design consists of an electrolyzer in charge mode and a separate fuel cell in discharge mode. Instead, a unitized regenerative fuel cell (URFC) is a single device performing both energy conversions, achieving a higher compactness and power-to-weight ratio. This paper presents a performance model of a URFC based on a proton exchange membrane (PEM) electrolyte and working on hydrogen and oxygen, which can provide high energy and power densities (>0.7 W cm-2). It provides voltage, power, and efficiency at varying load conditions as functions of the controlling physical quantities: temperature, pressure, concentration, and humidification. The model constitutes a tool for designing the interface and control sub-system as well as for exploring optimized cell/stack designs and operational conditions. To date, only a few of such analyses have been carried out and more research is needed in order to explore the true potential of URFCs.

  9. [Extracorporeal membrane oxygenation in primary graft dysfunction in a paediatric double lung transplant: presentation of a case].

    Science.gov (United States)

    López-Cantero, M; Grisolía, A L; Vicente, R; Moreno, I; Ramos, F; Porta, J; Torregrosa, S

    2014-04-01

    Primary graft dysfunction is a leading cause of morbimortality in the immediate postoperative period of patients undergoing lung transplantation. Among the treatment options are: lung protective ventilatory strategies, nitric oxide, lung surfactant therapy, and supportive treatment with extracorporeal membrane oxygenation (ECMO) as a bridge to recovery of lung function or re-transplant. We report the case of a 9-year-old girl affected by cystic fibrosis who underwent double-lung transplantation complicated with a severe primary graft dysfunction in the immediate postoperative period and refractory to standard therapies. Due to development of multiple organ failure, it was decided to insert arteriovenous ECMO catheters (pulmonary artery-right atrium). The postoperative course was satisfactory, allowing withdrawal of ECMO on the 5th post-surgical day. Currently the patient survives free of rejection and with an excellent quality of life after 600 days of follow up. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  10. Chest computed tomography in children undergoing extra-corporeal membrane oxygenation: a 9-year single-centre experience

    Energy Technology Data Exchange (ETDEWEB)

    Goodwin, Susie J.; Calder, Alistair D. [Great Ormond Street Hospital for Children NHS Foundation Trust, Radiology Department, London (United Kingdom); Randle, Elise; Iguchi, Akane; Brown, Katherine; Hoskote, Aparna [Great Ormond Street Hospital for Children NHS Foundation Trust, Cardiac Intensive Care and ECMO, London (United Kingdom)

    2014-06-15

    We retrospectively reviewed the imaging findings, indications, technique and clinical impact in children who had undergone chest CT while undergoing extra-corporeal membrane oxygenation (ECMO). Radiology and ECMO databases were searched to identify all 19 children who had undergone chest CT (20 scans in total) while on ECMO at our institution between May 2003 and May 2012. We reviewed all CT scans for imaging findings. Chest CT is performed in a minority of children on ECMO (4.5% in our series). Timing of chest CT following commencement of ECMO varied among patient groups but generally it was performed earlier in the neonatal group. Clinically significant imaging findings were found in the majority of chest CT scans. Many scans contained several findings, with most cases demonstrating parenchymal or pleural abnormalities. Case examples illustrate the spectrum of imaging findings, including underlying pathology such as necrotising pneumonia and severe barotrauma, and ECMO-related complications such as tension haemothoraces and cannula migration. The results of chest CT led to a change in patient management in 16 of 19 children (84%). There were no adverse events related to patient transfer. An understanding of scan technique and awareness of potential findings is important for the radiologist to provide prompt and optimal image acquisition and interpretation in appropriate patients. (orig.)

  11. Flow Rate Through Pigtail Catheter Used for Left Heart Decompression in an Artificial Model of Extracorporeal Membrane Oxygenation Circuit.

    Science.gov (United States)

    Kim, Won Ho; Hong, Tae Hee; Byun, Joung Hun; Kim, Jong Woo; Kim, Sung Hwan; Moon, Sung Ho; Park, Hyun Oh; Choi, Jun Young; Yang, Jun Ho; Jang, In Seok; Lee, Chung Eun; Yun, Jeong Hee

    In refractory cardiogenic shock, veno-arterial extracorporeal membrane oxygenation (ECMO) can be initiated. Although left heart decompression can be accomplished by insertion of a left atrial (LA) or left ventricular (LV) cannula using a percutaneous pigtail catheter, the venting flow rate according to catheter size and ECMO flow rate is unknown. We developed an artificial ECMO circuit. One liter saline bag with its pressure set to 20 mm Hg was connected to ECMO to mimic LV failure. A pigtail catheter was inserted into the 1 L saline bag to simulate LV unloading. For each pigtail catheter size (5-8 Fr) and ECMO flow rate (2.0-4.0 L/min), the moving distance of an air bubble that was injected through a three-way stopcock was measured in the arterial pressure line between the pigtail catheter and ECMO inflow limb. The flow rate was then calculated. We obtained the following equation to estimate the pigtail catheter flow rate.Pigtail vent catheter flow rate (ml/min) = 8×ECMOflow rate(L /min)+9×pigtail catheter size(Fr)- 57This equation would aid in designing of a further study to determine optimal venting flow rate. To achieve optimal venting flow, our equation would enable selection of an adequate catheter size.

  12. Valero Refinery Oxygen Enrichment Project

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  13. Development of novel CO{sub 2}-stable oxygen permeable dual phase membranes for CO{sub 2} capture in an oxy-fuel process

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Huixia

    2012-07-19

    The combustion of fossil fuels in power stations with pure oxygen following the oxy-fuel process allows the Sequestration of CO{sub 2}. The pure oxygen needed can be separated from air by oxygen transporting ceramics like single phase perovskites. However, most of the so far developed single phase perovskites have stability problems in a CO{sub 2} containing atmosphere. Dual phase membranes are micro-scale mixtures of an electron conducting phase and an oxygen ion conducting phase and their compositions can be tailored according to practical requirements, which are considered to be promising substitutes for the single phase perovskite materials. In my thesis the issues of phase stability for perovskite-type material with the common composition Ba{sub 0.5}Sr{sub 0.5}Co{sub 0.8}Fe{sub 3-{delta}} (BSCF) as weil as the development of a series of novel CO{sub 2}-stable dual phase membranes were studied. In Chapter 2, the phase stability and permeation behavior of a dead-end BSCF tube membrane in high-purity oxygen at temperatures below 750 C, were elucidated using powder X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDXS), high-angle annular dark-field (HAADF) and scanning transmission electron microscopy (STEM). lt was found that parts of the cubic perovskite BSCF transformed into a hexagonal perovskite Ba{sub 0.5{+-}x}Sr{sub 0.5{+-}x}CoO{sub 3-{delta}} (x {approx} 0.1) and a trigonal mixed oxide Ba{sub 1-x}Sr{sub x}CO{sub 2-y}Fe{sub y}O{sub 5{+-}{delta}} (x {approx} 0.15, y {approx} 0.25) in high-purity oxygen at 750 C. On the other hand, it was found that the partial degradation of cubic BSCF perovskite at 750 C was more pronounced under the strongly oxidizing conditions on the oxygen supply (feed) side than on the oxygen release (permeate) side of the membrane. The structural instability of BSCF is attributed to an oxidation of cobalt from Co{sup 2+} to Co{sup 3+} and Co{sup 4+}, which exhibits an ionic radius that is too small to be tolerated by

  14. An investigation of co-combustion municipal sewage sludge with biomass in a 20kW BFB combustor under air-fired and oxygen-enriched condition.

    Science.gov (United States)

    Kumar, Rajesh; Singh, Ravi Inder

    2017-12-01

    The behavior of municipal sewage sludge (MSS) with biomass (Guar stalks (GS), Mustard Husk (MH), Prosopis Juliflora Wood (PJW)) has been investigated in a 20kW bubbling fluidized bed (BFB) combustor under both air-fired (A-F) and oxygen-enriched (O-E) conditions. The work presented is divided into three parts, first part cover the thermogravimetric analysis (TGA), second part cover the experimental investigation of BFB combustor, and third part covers the ash analysis. TGA was performed with a ratio of 50%MSS/50%biomass (GS, MH, PJW) and results show that 50%MSS/50%GS has highest combustion characteristic factor (CCF). The experimental investigation of BFB combustor was performed for two different ratios of MSS/biomass (50%/50% and 25%/75%) and the combustion characteristics of blends were distinctive under both A-F and O-E condition. Despite 50%MSS/50%GS showing the highest combustion performance in TGA analysis, it formed agglomerates during burning in BFB. Due to this formation of large amount of agglomerates, de-fluidization was observed in the combustor bed after 65-75min in A-F conditions. The rate of de-fluidization increased under O-E condition. The de-fluidization problem disappeared when the share of MSS was reduced to 25%, but small amounts of the agglomerate were still present in the bed. With oxygen enhancement, the combustion efficiency of BFB combustor was improved and flue gasses were found within permissible limit. The maximum conceivable combustion efficiency (97.1%) for BFB combustor was accomplished by using 50% MSS/50%PJW under O-E condition. Results show that a ratio of 25%MSS/75%biomass combusted successfully inside the BFB combustor and extensive work is required for efficient utilization of significant share of MSS with biomass. SEM/EDS analyses were performed for agglomerate produced and for the damaged heater to study the surface morphology and compositions. The elemental heterogeneity of fly ash generated during MSS/biomass combustion

  15. In Vitro Comparative Study of Oxygen Plasma Treated Poly(Lactic⁻Co⁻Glycolic) (PLGA) Membranes and Supported Nanostructured Oxides for Guided Bone Regeneration Processes.

    Science.gov (United States)

    Torres-Lagares, Daniel; Castellanos-Cosano, Lizett; Serrera-Figallo, Maria-Angeles; López-Santos, Carmen; Barranco, Angel; Rodríguez-González-Elipe, Agustín; Gutierrez-Perez, Jose-Luis

    2018-05-08

    (1) Background: The use of physical barriers to prevent the invasion of gingival and connective tissue cells into bone cavities during the healing process is called guided bone regeneration. The objective of this in-vitro study was to compare the growth of human osteoblasts on Poly(Lactic⁻co⁻Glycolic) (PLGA) membranes modified with oxygen plasma and Hydroxyapatite (HA), silicon dioxide (SiO₂), and titanium dioxide (TiO₂) composite nanoparticles, respectively. (2) Methods: All the membranes received a common treatment with oxygen plasma and were subsequently treated with HA nanostructured coatings (n = 10), SiO₂ (n = 10) and TiO₂ (n = 10), respectively and a PLGA control membrane (n = 10). The assays were performed using the human osteoblast line MG-63 acquired from the Center for Scientific Instrumentation (CIC) from the University of Granada. The cell adhesion and the viability of the osteoblasts were analyzed by means of light-field microphotographs of each condition with the inverted microscope Axio Observer A1 (Carl Zeiss). For the determination of the mitochondrial energy balance, the MitoProbe™ JC-1 Assay Kit was employed. For the determination of cell growth and the morphology of adherent osteoblasts, two techniques were employed: staining with phalloidin-TRITC and staining with DAPI. (3) Results: The modified membranes that show osteoblasts with a morphology more similar to the control osteoblasts follow the order: PLGA/PO₂/HA > PLGA/PO₂/SiO₂ > PLGA/PO₂/TiO₂ > PLGA ( p membranes was observed as follows: PLGA/PO₂/SiO₂ > PLGA/PO₂/HA > PLGA/PO₂/TiO₂ > PLGA ( p membranes PLGA/PO₂/HA and PLGA/PO₂/SiO₂. (4) Conclusion: The membrane in which osteoblasts show characteristics more similar to the control osteoblasts is the PLGA/PO₂/HA, followed by the PLGA/PO₂/SiO₂.

  16. Usefulness of extracorporeal membrane oxygenation using double roller pumps in a low body weight newborn: A novel strategy for mechanical circulatory support in an infant

    Directory of Open Access Journals (Sweden)

    Keisuke Nakanishi

    2016-01-01

    Full Text Available Extracorporeal membrane oxygenation (ECMO with a centrifugal pump requires a certain flow rate; therefore, its application for low body weight infants is frequently accompanied by oxygenator membrane malfunction and/or inadequate perfusion. To prevent low-flow associated complications, we report a case in which a novel system of dual roller pumps was used. A baby girl with a body mass index 0.25 m 2 , who experienced difficulty weaning from cardiopulmonary bypass after a Norwood-like operation, required an ECMO. Concerns for the tube lifespan reduction due to roller pump friction led to the use of a double roller pump circulation. The termination of ECMO during tube exchange is not needed, because circulation is maintained by another roller pump. The novel strategy of ECMO with double roller pumps will allow low perfusion rate to provide adequate circulatory support for low body weight patients.

  17. Transcriptional responses of Leptospira interrogans to host innate immunity: significant changes in metabolism, oxygen tolerance, and outer membrane.

    Directory of Open Access Journals (Sweden)

    Feng Xue

    Full Text Available BACKGROUND: Leptospira interrogans is the major causative agent of leptospirosis. Phagocytosis plays important roles in the innate immune responses to L. interrogans infection, and L. interrogans can evade the killing of phagocytes. However, little is known about the adaptation of L. interrogans during this process. METHODOLOGY/PRINCIPAL FINDINGS: To better understand the interaction of pathogenic Leptospira and innate immunity, we employed microarray and comparative genomics analyzing the responses of L. interrogans to macrophage-derived cells. During this process, L. interrogans altered expressions of many genes involved in carbohydrate and lipid metabolism, energy production, signal transduction, transcription and translation, oxygen tolerance, and outer membrane proteins. Among them, the catalase gene expression was significantly up-regulated, suggesting it may contribute to resisting the oxidative pressure of the macrophages. The expressions of several major outer membrane protein (OMP genes (e.g., ompL1, lipL32, lipL41, lipL48 and ompL47 were dramatically down-regulated (10-50 folds, consistent with previous observations that the major OMPs are differentially regulated in vivo. The persistent down-regulations of these major OMPs were validated by immunoblotting. Furthermore, to gain initial insight into the gene regulation mechanisms in L. interrogans, we re-defined the transcription factors (TFs in the genome and identified the major OmpR TF gene (LB333 that is concurrently regulated with the major OMP genes, suggesting a potential role of LB333 in OMPs regulation. CONCLUSIONS/SIGNIFICANCE: This is the first report on global responses of pathogenic Leptospira to innate immunity, which revealed that the down-regulation of the major OMPs may be an immune evasion strategy of L. interrogans, and a putative TF may be involved in governing these down-regulations. Alterations of the leptospiral OMPs up interaction with host antigen

  18. Extracorporeal Membrane Oxygenation and Modern Detoxification Techniques in a Puerpera with Viral and Bacterial Pneumonia Caused by Flu A(H1N1 Virus

    Directory of Open Access Journals (Sweden)

    R. A. Kornelyuk

    2017-01-01

    Full Text Available Outbreaks of viral infections have become a global healthcare challenge over the last decade. The 2009—2010 flu A (H1N1 outbreak resulted in global pandemia, associated with high morbidity and mortality reaching 31%. Another flu A (H1N1 outbreak occurred in 2015—2016. There is a strong probability that it may be repeated in the future. This infection is associated with its high incidence among pregnant women. There are some published reports describing the efficacy and safety of veno%venous extracorporeal membrane oxygenation (ECMO in patients with severe acute respiratory distress syndrome that is refractory to standard therapeutic options. The article presents a clinical case of a successful use of extracorporeal membrane oxygenation and intermittent renal replacement therapy in a puerpera with acute respiratory distress syndrome caused by flu A (H1N1-related severe viral and bacterial pneumonia. The positive effects of the combination of veno%venous extracorporeal membrane oxygenation and modern detoxification techniques have been demonstrated. Revealed organizational problemswere related to selection criteria for prescription of extracorporeal gas exchange, as well as to carrying out the procedure in an institution in the deficiency of the experienced staff and corresponding equipment.

  19. Idiopathic pulmonary fibrosis patient supported with extracorporeal membrane oxygenation for 403 days while waiting for a lung transplant: A case report

    Directory of Open Access Journals (Sweden)

    Nao Umei, M.D.

    Full Text Available According to the Extracorporeal Life Support Organization, the average duration of veno-venous extracorporeal membrane oxygenation (V-V ECMO in adults with acute respiratory failure is 10.5–13.5 days. Some patients on V-V ECMO may not recover in such a short period of time, and recently, there have been more reports of prolonged V-V ECMO. However, we do not know how long it is feasible to wait for native lung recovery or lung transplant (LTx with the use of ECMO. We describe a patient with acute exacerbation of idiopathic pulmonary fibrosis supported by ECMO for 403 days while waiting for a LTx. In this case, we kept the patient awake, and he was communicating frequently with his family. We changed the membrane oxygenator 23 times and the cannula 10 times without complication. However, we terminated the treatment on day 403 of ECMO because there was no access site for cannula insertion due to blockage by a venous thrombotic occlusion, making it impossible to continue this bridge to lung transplantation. It has become possible to maintain patients on ECMO for extended periods of time, but it is difficult to manage ECMO for more than one year without the development of a more durable lung support system. Keywords: Lung transplantation, Extracorporeal membrane oxygenation, Idiopathic pulmonary fibrosis

  20. Extracorporeal Membrane Oxygenation (ECMO) for Severe Toxicological Exposures: Review of the Toxicology Investigators Consortium (ToxIC).

    Science.gov (United States)

    Wang, G S; Levitan, R; Wiegand, T J; Lowry, J; Schult, R F; Yin, S

    2016-03-01

    Although there have been many developments related to specific strategies for treating patients after poisoning exposures, the mainstay of therapy remains symptomatic and supportive care. One of the most aggressive supportive modalities is extracorporeal membrane oxygenation (ECMO). Our goal was to describe the use of ECMO for toxicological exposures reported to the American College of Medical Toxicology (ACMT) Toxicology Investigators Consortium (ToxIC). We performed a retrospective review of the ACMT ToxIC Registry from January 1, 2010 to December 31, 2013. Inclusion criteria included patients aged 0 to 89 years, evaluated between January 2010 through December 2013, and received ECMO for toxicological exposure. There were 26,271 exposures (60 % female) reported to the ToxIC Registry, 10 (0.0004 %) received ECMO: 4 pediatric (18 years). Time of initiation of ECMO ranged from 4 h to 4 days, with duration from 15 h to 12 days. Exposures included carbon monoxide/smoke inhalation (2), bitter almonds, methanol, and several medications including antihistamines (2), antipsychotic/antidepressant (2), cardiovascular drugs (2), analgesics (2), sedative/hypnotics (2), and antidiabetics (2). Four ECMO patients received cardiopulmonary resuscitation (CPR) during their hospital course, and the overall survival rate was 80 %. ECMO was rarely used for poisoning exposures in the ACMT ToxIC Registry. ECMO was utilized for a variety of ages and for pharmaceutical and non-pharmaceutical exposures. In most cases, ECMO was administered prior to cardiovascular failure, and survival rate was high. If available, ECMO may be a valid treatment modality.

  1. Simultaneous evaluation of substrate-dependent oxygen consumption rates and mitochondrial membrane potential by TMRM and safranin in cortical mitochondria.

    Science.gov (United States)

    Chowdhury, Subir Roy; Djordjevic, Jelena; Albensi, Benedict C; Fernyhough, Paul

    2015-12-08

    Mitochondrial membrane potential (mtMP) is critical for maintaining the physiological function of the respiratory chain to generate ATP. The present study characterized the inter-relationship between mtMP, using safranin and tetramethyl rhodamine methyl ester (TMRM), and mitochondrial respiratory activity and established a protocol for functional analysis of mitochondrial bioenergetics in a multi-sensor system. Coupled respiration was decreased by 27 and 30-35% in the presence of TMRM and safranin respectively. Maximal respiration was higher than coupled with Complex I- and II-linked substrates in the presence of both dyes. Safranin showed decreased maximal respiration at a higher concentration of carbonyl cyanide-4-(trifluoromethoxy)phenylhydrazone (FCCP) compared with TMRM. FCCP titration revealed that maximal respiration in the presence of glutamate and malate was not sustainable at higher FCCP concentrations as compared with pyruvate and malate. Oxygen consumption rate (OCR) and mtMP in response to mitochondrial substrates were higher in isolated mitochondria compared with tissue homogenates. Safranin exhibited higher sensitivity to changes in mtMP than TMRM. This multi-sensor system measured mitochondrial parameters in the brain of transgenic mice that model Alzheimer's disease (AD), because mitochondrial dysfunction is believed to be a primary event in the pathogenesis of AD. The coupled and maximal respiration of electron transport chain were decreased in the cortex of AD mice along with the mtMP compared with age-matched controls. Overall, these data demonstrate that safranin and TMRM are suitable for the simultaneous evaluation of mtMP and respiratory chain activity using isolated mitochondria and tissue homogenate. However, certain care should be taken concerning the selection of appropriate substrates and dyes for specific experimental circumstances. © 2016 Authors.

  2. High-performance Platinum-free oxygen reduction reaction and hydrogen oxidation reaction catalyst in polymer electrolyte membrane fuel cell.

    Science.gov (United States)

    Chandran, Priji; Ghosh, Arpita; Ramaprabhu, Sundara

    2018-02-26

    The integration of polymer electrolyte membrane fuel cell (PEMFC) stack into vehicles necessitates the replacement of high-priced platinum (Pt)-based electrocatalyst, which contributes to about 45% of the cost of the stack. The implementation of high-performance and durable Pt metal-free catalyst for both oxygen reduction reaction (ORR) and hydrogen oxidation reaction (HOR) could significantly enable large-scale commercialization of fuel cell-powered vehicles. Towards this goal, a simple, scalable, single-step synthesis method was adopted to develop palladium-cobalt alloy supported on nitrogen-doped reduced graphene oxide (Pd 3 Co/NG) nanocomposite. Rotating ring-disk electrode (RRDE) studies for the electrochemical activity towards ORR indicates that ORR proceeds via nearly four-electron mechanism. Besides, the mass activity of Pd 3 Co/NG shows an enhancement of 1.6 times compared to that of Pd/NG. The full fuel cell measurements were carried out using Pd 3 Co/NG at the anode, cathode in conjunction with Pt/C and simultaneously at both anode and cathode. A maximum power density of 68 mW/cm 2 is accomplished from the simultaneous use of Pd 3 Co/NG as both anode and cathode electrocatalyst with individual loading of 0.5 mg/cm 2 at 60 °C without any backpressure. To the best of our knowledge, the present study is the first of its kind of a fully non-Pt based PEM full cell.

  3. Iridium-decorated palladium-platinum core-shell catalysts for oxygen reduction reaction in proton exchange membrane fuel cell.

    Science.gov (United States)

    Wang, Chen-Hao; Hsu, Hsin-Cheng; Wang, Kai-Ching

    2014-08-01

    Carbon-supported Pt, Pd, Pd-Pt core-shell (Pt(shell)-Pd(core)/C) and Ir-decorated Pd-Pt core-shell (Ir-decorated Pt(shell)-Pd(core)/C) catalysts were synthesized, and their physical properties, electrochemical behaviors, oxygen reduction reaction (ORR) characteristics and proton exchange membrane fuel cell (PEMFC) performances were investigated herein. From the XRD patterns and TEM images, Ir-decorated Pt(shell)-Pd(core)/C has been confirmed that Pt was deposited on the Pd nanoparticle which had the core-shell structure. Ir-decorated Pt(shell)-Pd(core)/C has more positive OH reduction peak than Pt/C, which is beneficial to weaken the binding energy of Pt-OH during the ORR. Thus, Ir-decorated Pt(shell)-Pd(core)/C has higher ORR activity than Pt/C. The maximum power density of H2-O2 PEMFC using Ir-decorated Pt(shell)-Pd(core)/C is 792.2 mW cm(-2) at 70°C, which is 24% higher than that using Pt/C. The single-cell accelerated degradation test of PEMFC using Ir-decorated Pt(shell)-Pd(core)/C shows good durability by the potential cycling of 40,000 cycles. This study concludes that Ir-decorated Pt(shell)-Pd(core)/C has the low Pt content, but it can facilitate the low-cost and high-efficient PEMFC. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Micro-Membrane Electrode Assembly Design to Precisely Measure the in Situ Activity of Oxygen Reduction Reaction Electrocatalysts for PEMFC.

    Science.gov (United States)

    Long, Zhi; Li, Yankai; Deng, Guangrong; Liu, Changpeng; Ge, Junjie; Ma, Shuhua; Xing, Wei

    2017-06-20

    An in situ micro-MEA technique, which could precisely measure the performance of ORR electrocatalyst using Nafion as electrolyte, was designed and compared with regular thin-film rotating-disk electrode (TFRDE) (0.1 M HClO 4 ) and normal in situ membrane electrode assembly (MEA) tests. Compared to the traditional TFRDE method, the micro-MEA technique makes the acquisition of catalysts' behavior at low potential values easily achieved without being limited by the solubility of O 2 in water. At the same time, it successfully mimics the structure of regular MEAs and obtains similar results to a regular MEA, thus providing a new technique to simply measure the electrode activity without being bothered by complicated fabrication of regular MEA. In order to further understand the importance of in situ measurement, Fe-N-C as a typical oxygen reduction reaction (ORR) free-Pt catalyst was evaluated by TFRDE and micro-MEA. The results show that the half wave potential of Fe-N-C only shifted negatively by -135 mV in comparison with state-of-the-art Pt/C catalysts from TFRDE tests. However, the active site density, mass transfer of O 2 , and the proton transfer conductivity are found to strongly influence the catalyst activity in the micro-MEA, thereby resulting in a much lower limiting current density than Pt/C (8.7 times lower). Hence, it is suggested that the micro-MEA is better in evaluating the in situ ORR performance, where the catalysts are characterized more thoroughly in terms of intrinsic activity, active site density, proton transfer, and mass transfer properties.

  5. The HAT Score-A Simple Risk Stratification Score for Coagulopathic Bleeding During Adult Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Lonergan, Terence; Herr, Daniel; Kon, Zachary; Menaker, Jay; Rector, Raymond; Tanaka, Kenichi; Mazzeffi, Michael

    2017-06-01

    The study objective was to create an adult extracorporeal membrane oxygenation (ECMO) coagulopathic bleeding risk score. Secondary analysis was performed on an existing retrospective cohort. Pre-ECMO variables were tested for association with coagulopathic bleeding, and those with the strongest association were included in a multivariable model. Using this model, a risk stratification score was created. The score's utility was validated by comparing bleeding and transfusion rates between score levels. Bleeding also was examined after stratifying by nadir platelet count and overanticoagulation. Predictive power of the score was compared against the risk score for major bleeding during anti-coagulation for atrial fibrillation (HAS-BLED). Tertiary care academic medical center. The study comprised patients who received venoarterial or venovenous ECMO over a 3-year period, excluding those with an identified source of surgical bleeding during exploration. None. Fifty-three (47.3%) of 112 patients experienced coagulopathic bleeding. A 3-variable score-hypertension, age greater than 65, and ECMO type (HAT)-had fair predictive value (area under the receiver operating characteristic curve [AUC] = 0.66) and was superior to HAS-BLED (AUC = 0.64). As the HAT score increased from 0 to 3, bleeding rates also increased as follows: 30.8%, 48.7%, 63.0%, and 71.4%, respectively. Platelet and fresh frozen plasma transfusion tended to increase with the HAT score, but red blood cell transfusion did not. Nadir platelet count less than 50×10 3 /µL and overanticoagulation during ECMO increased the AUC for the model to 0.73, suggesting additive risk. The HAT score may allow for bleeding risk stratification in adult ECMO patients. Future studies in larger cohorts are necessary to confirm these findings. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Lysosomal membrane permeabilization: Carbon nanohorn-induced reactive oxygen species generation and toxicity by this neglected mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Mei, E-mail: happy_deercn@163.com [Nanotube Research Center, National Institute of Advanced Industrial Science and Technology 5-2, 1-1-1 Higashi, Tsukuba 305-8565 (Japan); Zhang, Minfang; Tahara, Yoshio; Chechetka, Svetlana; Miyako, Eijiro [Nanotube Research Center, National Institute of Advanced Industrial Science and Technology 5-2, 1-1-1 Higashi, Tsukuba 305-8565 (Japan); Iijima, Sumio [Nanotube Research Center, National Institute of Advanced Industrial Science and Technology 5-2, 1-1-1 Higashi, Tsukuba 305-8565 (Japan); Faculty of Science and Technology, Meijo University, 1-501 Shiogamaguchi, Tenpaku, Nagoya 468-8502 (Japan); Yudasaka, Masako, E-mail: m-yudasaka@aist.go.jp [Nanotube Research Center, National Institute of Advanced Industrial Science and Technology 5-2, 1-1-1 Higashi, Tsukuba 305-8565 (Japan)

    2014-10-01

    Understanding the molecular mechanisms responsible for the cytotoxic effects of carbon nanomaterials is important for their future biomedical applications. Carbon nanotubular materials induce the generation of reactive oxygen species (ROS), which causes cell death; however, the exact details of this process are still unclear. Here, we identify a mechanism of ROS generation that is involved in the apoptosis of RAW264.7 macrophages caused by excess uptake of carbon nanohorns (CNHs), a typical type of carbon nanotubule. CNH accumulated in the lysosomes, where they induced lysosomal membrane permeabilization (LMP) and the subsequent release of lysosomal proteases, such as cathepsins, which in turn caused mitochondrial dysfunction and triggered the generation of ROS in the mitochondria. The nicotinamide adenine dinucleotide phosphate oxidase was not directly involved in CNH-related ROS production, and the ROS generation cannot be regulated by mitochondrial electron transport chain. ROS fed back to amplify the mitochondrial dysfunction, leading to the subsequent activation of caspases and cell apoptosis. Carbon nanotubules commonly accumulate in the lysosomes after internalization in cells; however, lysosomal dysfunction has not attracted much attention in toxicity studies of these materials. These results suggest that LMP, a neglected mechanism, may be the primary reason for carbon nanotubule toxicity. - Highlights: • We clarify an apoptotic mechanism of RAW264.7 cells caused by carbon nanohorns. • In the meantime, the mechanism of CNH-induced ROS generation is identified. • LMP is the initial factor of CNH-induced ROS generation and cell death. • Cathepsins work as mediators that connect LMP and mitochondrial dysfunction.

  7. The "basic" approach: a single-centre experience with a cost-reducing model for paediatric cardiac extracorporeal membrane oxygenation.

    Science.gov (United States)

    Padalino, Massimo A; Tessari, Chiara; Guariento, Alvise; Frigo, Anna C; Vida, Vladimiro L; Marcolongo, Andrea; Zanella, Fabio; Harvey, Michael J; Thiagarajan, Ravi R; Stellin, Giovanni

    2017-04-01

    Extracorporeal membrane oxygenation (ECMO) is a lifesaving but expensive therapy in terms of financial, technical and human resources. We report our experience with a 'basic' ECMO support model, consisting of ECMO initiated and managed without the constant presence of a bedside specialist, to assess safety, clinical outcomes and financial impact on our health system. We did a retrospective single-centre study of paediatric cardiac ECMO between January 2001 and March 2014. Outcomes included postimplant complications and survival at weaning and at discharge. We used activity based costing to compare the costs of current basic ECMO with those of a 'full optional' dedicated ECMO team (hypothesis 1); ECMO with a bedside nurse and perfusionist (hypothesis 2), and ECMO with a bedside perfusionist (hypothesis 3). Basic cardiac ECMO was required for 121 patients (median age 75 days, median weight 4.4 kg). A total of 107 patients (88%) had congenital heart disease; 37 had univentricular physiology. The median duration of ECMO was 7 days (interquartile range [IQR], 4-15 days). Overall survival at weaning and at 30 days in the neonatal and paediatric age groups was 58.6% and 30.6%, respectively; these results were not significantly different from Extracorporeal Life Support Organization data. Cost analysis revealed a saving of €30 366, €22 144 and €13 837 for each patient on basic ECMO for hypotheses 1, 2 and 3, respectively. Despite reduced human, technical and economical resources, a basic ECMO model without a bedside specialist was associated with satisfactory survival and lower costs. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. OXYGEN TRANSPORT CERAMIC MEMBRANES

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Sukumar Bandopadhyay; Dr. Nagendfra Nagabhushana

    2001-07-01

    The mechanical properties of model systems were analyzed. A reasonably accurate finite element model was implemented and a rational metric to predict the strength of ceramic/metal concentrical joints was developed. The mode of failure of the ceramic/metal joints was determined and the importance of the mechanical properties of the braze material was assessed. Thermal cycling experiments were performed on the model systems and the results were discussed. Additionally, experiments using the concept of placing diffusion barriers on the ceramic surface to limit the extent of the reaction with the braze were performed. It was also observed that the nature and morphology of the reaction zone depends greatly on the nature of the perovskite structure being used. From the experiments, it is observed that the presence of Cr in the Fe-occupied sites decreases the tendency of Fe to segregate and to precipitate out of the lattice. In these new experiments, Ni was observed to play a major role in the decomposition of the ceramic substrate.

  9. Uranium enrichment. Enrichment processes

    International Nuclear Information System (INIS)

    Alexandre, M.; Quaegebeur, J.P.

    2009-01-01

    Despite the remarkable progresses made in the diversity and the efficiency of the different uranium enrichment processes, only two industrial processes remain today which satisfy all of enriched uranium needs: the gaseous diffusion and the centrifugation. This article describes both processes and some others still at the demonstration or at the laboratory stage of development: 1 - general considerations; 2 - gaseous diffusion: physical principles, implementation, utilisation in the world; 3 - centrifugation: principles, elementary separation factor, flows inside a centrifuge, modeling of separation efficiencies, mechanical design, types of industrial centrifuges, realisation of cascades, main characteristics of the centrifugation process; 4 - aerodynamic processes: vortex process, nozzle process; 5 - chemical exchange separation processes: Japanese ASAHI process, French CHEMEX process; 6 - laser-based processes: SILVA process, SILMO process; 7 - electromagnetic and ionic processes: mass spectrometer and calutron, ion cyclotron resonance, rotating plasmas; 8 - thermal diffusion; 9 - conclusion. (J.S.)

  10. Thermal Behavior and Hydrogen Production of Methanol Autothermal Reforming Performed Using Oxygen Enrichment and Cu/ZnO/Al2O3/Cr2O3/CeO2 Catalyst

    Directory of Open Access Journals (Sweden)

    Donny Lesmana

    2015-07-01

    Full Text Available A fixed-bed reactor designed for the autothermal reforming (ATR of methanol under adiabatic conditions was constructed to experimentally determine the profile of temperature and catalyst activity generated using the Cu/ZnO/Al2O3/Cr2O3/CeO2 catalyst. The effect of oxygen enrichment in this experiment was investigated, and the experimental results showed that an increase in oxygen concentration correlated with an increase in the temperature of the catalytic bed; by contrast, this increase in oxygen concentration resulted in a reduction of the startup time of the catalyst. Moreover, the reaction temperature was determined to vary with the position within the catalytic fixed bed. © 2015 BCREC UNDIP. All rights reservedReceived: 29th August 2014; Revised: 19th March 2015; Accepted: 19th March 2015

  11. Regional perfusion by extracorporeal membrane oxygenation of abdominal organs from donors after circulatory death: a systematic review.

    Science.gov (United States)

    Shapey, Iestyn M; Muiesan, Paolo

    2013-12-01

    Organs from donors after circulatory death (DCDs) are particularly susceptible to the effects of warm ischemia injury. Regional perfusion (RP) by extracorporeal membrane oxygenation (ECMO) is increasingly being advocated as a useful remedy to the effects of ischemia/reperfusion injury, and it has been reported to enable the transplantation of organs from donors previously deemed unsuitable. The MEDLINE, Embase, and Cochrane databases were searched, and articles published between 1997 and 2013 were obtained. A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Two hundred ten articles were identified, and 11 were eligible for inclusion. Four hundred eighty-two kidneys and 79 livers were transplanted from regional perfusion-supported donor after circulatory death (RP-DCD) sources. One-year graft survival was lower with uncontrolled RP-DCD liver transplantation, whereas 1-year patient survival was similar. Primary nonfunction and ischemic cholangiopathy were significantly more frequent with RP-DCDs versus donors after brain death (DBDs), but there was no difference in postoperative mortality between the 2 groups. The 1-year patient and graft survival rates for RP-DCD kidney transplantation were better than the rates with standard DCDs and were comparable to, if not better than, the rates with DBDs. At experienced centers, delayed graft function (DGF) for kidney transplantation from RP-DCDs was much less frequent in comparison with all other donor types. In conclusion, RP aids the recovery of DCD organs from ischemic injury and enables transplantation with acceptable survival. RP may help to increase the donor pool, but its benefits must still be balanced with the recognition of significantly higher rates of complications in liver transplantation. In kidney transplantation, significant reductions in DGF can be obtained with RP, and there are potentially important implications for long

  12. National review of use of extracorporeal membrane oxygenation as respiratory support in thoracic surgery excluding lung transplantation.

    Science.gov (United States)

    Rinieri, Philippe; Peillon, Christophe; Bessou, Jean-Paul; Veber, Benoît; Falcoz, Pierre-Emmanuel; Melki, Jean; Baste, Jean-Marc

    2015-01-01

    Extracorporeal membrane oxygenation (ECMO) for respiratory support is increasingly used in intensive care units (ICU), but rarely during thoracic surgical procedures outside the transplantation setting. ECMO can be an alternative to cardiopulmonary bypass for major trachea-bronchial surgery and single-lung procedures without in-field ventilation. Our aim was to evaluate the intraoperative use of ECMO as respiratory support in thoracic surgery: benefits, indications and complications. This was a multicentre retrospective study (questionnaire) of use of ECMO as respiratory support during the thoracic surgical procedure. Lung transplantation and lung resection for tumour invading the great vessels and/or the left atrium were excluded, because they concern respiratory and circulatory support. From March 2009 to September 2012, 17 of the 34 centres in France applied ECMO within veno-venous (VV) (n=20) or veno-arterial (VA) (n=16) indications in 36 patients. Ten VA ECMO were performed with peripheral cannulation and 6 with central cannulation; all VV ECMO were achieved through peripheral cannulation. Group 1 (total respiratory support) was composed of 28 patients without mechanical ventilation, involving 23 tracheo-bronchial and 5 single-lung procedures. Group 2 (partial respiratory support) was made up of 5 patients with respiratory insufficiency. Group 3 was made up of 3 patients who underwent thoracic surgery in a setting of acute respiratory distress syndrome (ARDS) with preoperative ECMO. Mortality at 30 days in Groups 1, 2 and 3 was 7, 40 and 67%, respectively (P<0.05). In Group 1, ECMO was weaned intraoperatively or within 24 h in 75% of patients. In Group 2, ECMO was weaned in ICU over several days. In Group 1, 2 patients with VA support were converted to VV support for chronic respiratory indications. Bleeding was the major complication with 17% of patients requiring return to theatre for haemostasis. There were two cannulation-related complications (6%). VV or

  13. The use of extracorporeal membrane oxygenation in blunt thoracic trauma: A study of the Extracorporeal Life Support Organization database.

    Science.gov (United States)

    Jacobs, Jordan V; Hooft, Nicole M; Robinson, Brenton R; Todd, Emily; Bremner, Ross M; Petersen, Scott R; Smith, Michael A

    2015-12-01

    Reports documenting the use of extracorporeal membrane oxygenation (ECMO) after blunt thoracic trauma are scarce. We used a large, multicenter database to examine outcomes when ECMO was used in treating patients with blunt thoracic trauma. We performed a retrospective analysis of ECMO patients in the Extracorporeal Life Support Organization database between 1998 and 2014. The diagnostic code for blunt pulmonary contusion (861.21, DRG International Classification of Diseases-9th Rev.) was used to identify patients treated with ECMO after blunt thoracic trauma. Variations of pre-ECMO respiratory support were also evaluated. The primary outcome was survival to discharge; the secondary outcome was hemorrhagic complication associated with ECMO. Eighty-five patients met inclusion criteria. The mean ± SEM age of the cohort was 28.9 ± 1.1 years; 71 (83.5%) were male. The mean ± SEM pre-ECMO PaO2/FIO2 ratio was 59.7 ± 3.5, and the mean ± SEM pre-ECMO length of ventilation was 94.7 ± 13.2 hours. Pre-ECMO support included inhaled nitric oxide (15 patients, 17.6%), high-frequency oscillation (10, 11.8%), and vasopressor agents (57, 67.1%). The mean ± SEM duration of ECMO was 207.4 ± 23.8 hours, and 63 patients (74.1%) were treated with venovenous ECMO. Thirty-two patients (37.6%) underwent invasive procedures before ECMO, and 12 patients (14.1%) underwent invasive procedures while on ECMO. Hemorrhagic complications occurred in 25 cases (29.4%), including 12 patients (14.1%) with surgical site bleeding and 16 (18.8%) with cannula site bleeding (6 patients had both). The rate of survival to discharge was 74.1%. Multivariate analysis showed that shorter duration of ECMO and the use of venovenous ECMO predicted survival. Outcomes after the use of ECMO in blunt thoracic trauma can be favorable. Some trauma patients are appropriate candidates for this therapy. Further study may discern which subpopulations of trauma patients will benefit most from ECMO. Therapeutic

  14. Constants of the Alper and Howard-Flanders oxygen equation for damage to bacterial membrane, deduced from observations on the radiation-induced penicillin-sensitive lesion

    International Nuclear Information System (INIS)

    Obioha, F.I.; Gillies, N.E.; Cullen, B.M.; Walker, H.C.; Alper, T.

    1984-01-01

    E. coli were irradiated in the presence of 100% oxygen, oxygen-free nitrogen and mixtures of 1.01, 0.59, 0.3, 0.1 and 0.06% oxygen in nitrogen. Changes in sensitivity with pO 2 conformed with the Alper and Howard-Flanders equation for bacteria treated after irradiation by penicillin as well as for the untreated ones. Values of m were respectively 4.8 and 3.3; values of K were identical, within experimental error, (4.4 mmHg). Sensitivity to induction of the bacterial membrane penicillin-sensitive lesion was calculated from the difference in the reciprocals of D 0 values proper to untreated and treated bacteria, for every gas used. The value of m could not be directly calculated because the effect of penicillin on anoxically irradiated bacteria was not detectable. For that reason, a transformation of the oxygen equation was used, allowing estimates to be made of both m and K, provided the results conformed with the equation. Within experimental error they did. Calculated values of m and K for induction of the penicillin-sensitive lesion were respectively 8 and 5.9 mmHg, but it is shown that the oxygen enhancement ratio was probably underestimated and the value overestimated. (author)

  15. DEVELOPMENT OF REACTION-DRIVEN IONIC TRANSPORT MEMBRANES (ITMs) TECHNOLOGY: PHASE IV/BUDGET PERIOD 6 “Development of ITM Oxygen Technology for Integration in IGCC and Other Advanced Power Generation Systems”

    Energy Technology Data Exchange (ETDEWEB)

    David, Studer

    2012-03-01

    Air Products and Chemicals, along with development participants and in association with the U.S. Department of Energy, has made substantial progress in developing a novel air separation technology. Unlike conventional cryogenic processes, this method uses high-temperature ceramic membranes to produce high-purity oxygen. The membranes selectively transport oxygen ions with high flux and infinite theoretical selectivity. Reaction-driven ceramic membranes are fabricated from non-porous, multi-component metallic oxides, operate at temperatures typically over 700°C, and have exceptionally high oxygen flux and selectivity. Oxygen from low-pressure air permeates as oxygen ions through the ceramic membrane and is consumed through chemical reactions, thus creating a chemical driving force that pulls oxygen ions across the membrane at high rates. The oxygen reacts with a hydrocarbon fuel in a partial oxidation process to produce a hydrogen and carbon monoxide mixture – synthesis gas. This project expands the partial-oxidation scope of ITM technology beyond natural gas feed and investigates the potential for ITM reaction-driven technology to be used in conjunction with gasification and pyrolysis technologies to provide more economical routes for producing hydrogen and synthesis gas. This report presents an overview of the ITM reaction-driven development effort, including ceramic materials development, fabrication and testing of small-scale ceramic modules, ceramic modeling, and the investigation of gasifier integration schemes

  16. Inkjet printing of nanoporous gold electrode arrays on cellulose membranes for high-sensitive paper-like electrochemical oxygen sensors using ionic liquid electrolytes.

    Science.gov (United States)

    Hu, Chengguo; Bai, Xiaoyun; Wang, Yingkai; Jin, Wei; Zhang, Xuan; Hu, Shengshui

    2012-04-17

    A simple approach to the mass production of nanoporous gold electrode arrays on cellulose membranes for electrochemical sensing of oxygen using ionic liquid (IL) electrolytes was established. The approach, combining the inkjet printing of gold nanoparticle (GNP) patterns with the self-catalytic growth of these patterns into conducting layers, can fabricate hundreds of self-designed gold arrays on cellulose membranes within several hours using an inexpensive inkjet printer. The resulting paper-based gold electrode arrays (PGEAs) had several unique properties as thin-film sensor platforms, including good conductivity, excellent flexibility, high integration, and low cost. The porous nature of PGEAs also allowed the addition of electrolytes from the back cellulose membrane side and controllably produced large three-phase electrolyte/electrode/gas interfaces at the front electrode side. A novel paper-based solid-state electrochemical oxygen (O(2)) sensor was therefore developed using an IL electrolyte, 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF(6)). The sensor looked like a piece of paper but possessed high sensitivity for O(2) in a linear range from 0.054 to 0.177 v/v %, along with a low detection limit of 0.0075% and a short response time of less than 10 s, foreseeing its promising applications in developing cost-effective and environment-friendly paper-based electrochemical gas sensors.

  17. Structural stability and oxygen permeability of BaCo{sub 1−x}Nb{sub x}O{sub 3−δ} ceramic membranes for air separation

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Chengzhang, E-mail: wucz@shu.edu.cn [Shanghai Key Laboratory of Modern Metallurgy and Materials Processing, Shanghai University, Shanghai 200072 (China); Gai, Yongqian; Zhou, Jianfang; Tang, Xia; Zhang, Yunwen; Ding, Weizhong [Shanghai Key Laboratory of Modern Metallurgy and Materials Processing, Shanghai University, Shanghai 200072 (China); Sun, Chenghua [School of Chemistry, Monash University, Clayton, VIC 3800 (Australia)

    2015-07-25

    Highlights: • BCNx membranes with high oxygen permeation flux were prepared. • Oxygen permeability of BCNx membranes is stable at 900 °C. • Phase transition is governed by oxygen partial pressure and temperature. • Degradation mechanism of BCNx membrane is suggested. - Abstract: BaCo{sub 1−x}Nb{sub x}O{sub 3−δ} (BCNx, x = 0.1–0.2) membranes were synthesized through conventional solid-phase reactions. The introduction of niobium facilitates the formation of the cubic perovskite structure and decreases oxygen nonstoichiometry. BCNx membranes possess higher oxygen permeation flux compared with BaCo{sub 0.7}Fe{sub 0.2}Nb{sub 0.1}O{sub 3−δ} membrane at the same condition. A stable permeation flux as high as 2.61 ml cm{sup −2} min{sup −1} is obtained through BaCo{sub 0.9}Nb{sub 0.1}O{sub 3−δ} membrane at 900 °C under the Air/He gradient. Long-time permeation study shows that the oxygen fluxes of BCNx membranes are stable at 900 °C but degrade slowly with time at 850 °C. XRD and TG–DSC results indicate that the degradation behavior occured at 850 °C is due to the phase transition from the cubic perovskite to monoclinic or orthorhombic structure, which is governed by the oxygen partial pressure and temperature. The oxidation of cobalt ion is considered to be the nature for the phase transition, which makes the tolerance factor increasing and results in structural destabilization.

  18. In Vitro Comparative Study of Oxygen Plasma Treated Poly(Lactic–Co–Glycolic (PLGA Membranes and Supported Nanostructured Oxides for Guided Bone Regeneration Processes

    Directory of Open Access Journals (Sweden)

    Daniel Torres-Lagares

    2018-05-01

    Full Text Available (1 Background: The use of physical barriers to prevent the invasion of gingival and connective tissue cells into bone cavities during the healing process is called guided bone regeneration. The objective of this in-vitro study was to compare the growth of human osteoblasts on Poly(Lactic–co–Glycolic (PLGA membranes modified with oxygen plasma and Hydroxyapatite (HA, silicon dioxide (SiO2, and titanium dioxide (TiO2 composite nanoparticles, respectively. (2 Methods: All the membranes received a common treatment with oxygen plasma and were subsequently treated with HA nanostructured coatings (n = 10, SiO2 (n = 10 and TiO2 (n = 10, respectively and a PLGA control membrane (n = 10. The assays were performed using the human osteoblast line MG-63 acquired from the Center for Scientific Instrumentation (CIC from the University of Granada. The cell adhesion and the viability of the osteoblasts were analyzed by means of light-field microphotographs of each condition with the inverted microscope Axio Observer A1 (Carl Zeiss. For the determination of the mitochondrial energy balance, the MitoProbe™ JC-1 Assay Kit was employed. For the determination of cell growth and the morphology of adherent osteoblasts, two techniques were employed: staining with phalloidin-TRITC and staining with DAPI. (3 Results: The modified membranes that show osteoblasts with a morphology more similar to the control osteoblasts follow the order: PLGA/PO2/HA > PLGA/PO2/SiO2 > PLGA/PO2/TiO2 > PLGA (p < 0.05. When analysing the cell viability, a higher percentage of viable cells bound to the membranes was observed as follows: PLGA/PO2/SiO2 > PLGA/PO2/HA > PLGA/PO2/TiO2 > PLGA (p < 0.05, with a better energy balance of the cells adhered to the membranes PLGA/PO2/HA and PLGA/PO2/SiO2. (4 Conclusion: The membrane in which osteoblasts show characteristics more similar to the control osteoblasts is the PLGA/PO2/HA, followed by the PLGA/PO2/SiO2.

  19. Free-Flow Electrophoresis of Plasma Membrane Vesicles Enriched by Two-Phase Partitioning Enhances the Quality of the Proteome from Arabidopsis Seedlings.

    Science.gov (United States)

    de Michele, Roberto; McFarlane, Heather E; Parsons, Harriet T; Meents, Miranda J; Lao, Jeemeng; González Fernández-Niño, Susana M; Petzold, Christopher J; Frommer, Wolf B; Samuels, A Lacey; Heazlewood, Joshua L

    2016-03-04

    The plant plasma membrane is the interface between the cell and its environment undertaking a range of important functions related to transport, signaling, cell wall biosynthesis, and secretion. Multiple proteomic studies have attempted to capture the diversity of proteins in the plasma membrane using biochemical fractionation techniques. In this study, two-phase partitioning was combined with free-flow electrophoresis to produce a population of highly purified plasma membrane vesicles that were subsequently characterized by tandem mass spectroscopy. This combined high-quality plasma membrane isolation technique produced a reproducible proteomic library of over 1000 proteins with an extended dynamic range including plasma membrane-associated proteins. The approach enabled the detection of a number of putative plasma membrane proteins not previously identified by other studies, including peripheral membrane proteins. Utilizing multiple data sources, we developed a PM-confidence score to provide a value indicating association to the plasma membrane. This study highlights over 700 proteins that, while seemingly abundant at the plasma membrane, are mostly unstudied. To validate this data set, we selected 14 candidates and transiently localized 13 to the plasma membrane using a fluorescent tag. Given the importance of the plasma membrane, this data set provides a valuable tool to further investigate important proteins. The mass spectrometry data are available via ProteomeXchange, identifier PXD001795.

  20. Enhancing co-production of H2 and syngas via water splitting and POM on surface-modified oxygen permeable membranes

    KAUST Repository

    Wu, Xiao-Yu

    2016-09-26

    In this article, we report a detailed study on co-production of H2 and syngas on La0.9Ca0.1FeO3−δ (LCF-91) membranes via water splitting and partial oxidation of methane, respectively. A permeation model shows that the surface reaction on the sweep side is the rate limiting step for this process on a 0.9 mm-thick dense membrane at 990°C. Hence, sweep side surface modifications such as adding a porous layer and nickel catalysts were applied; the hydrogen production rate from water thermolysis is enhanced by two orders of magnitude to 0.37 μmol/cm2•s compared with the results on the unmodified membrane. At the sweep side exit, syngas (H2/CO = 2) is produced and negligible solid carbon is found. Yet near the membrane surface on the sweep side, methane can decompose into solid carbon and hydrogen at the surface, or it may be oxidized into CO and CO2, depending on the oxygen permeation flux.

  1. The Use of Extracorporeal Membrane Oxygenation-Cardiopulmonary Resuscitation in Prolonged Cardiac Arrest in Pediatric Patients: Is it Time to Expand It?

    Science.gov (United States)

    Absi, Mohammed; Kumar, Susheel Tk; Sandhu, Hitesh

    2017-09-01

    Extracorporeal membrane oxygenation was instituted as an aid to in-hospital cardiopulmonary resuscitation (E-CPR) nearly 23 years ago, this led to remarkable improvement in survival considering the mortality rate associated with conventional cardiopulmonary resuscitation (CPR). Given this success, one begins to wonder whether the time has come for expanding the use of E-CPR to outside hospital cardiac arrests especially in the light of development of newer extracorporeal life support devices that are small, mobile, and easy to assemble. This editorial will review recent studies on this subject and address some key guidelines and limitations of this evolving and promising technology.

  2. Ethical dilemma: offering short-term extracorporeal membrane oxygenation support for terminally ill children who are not candidates for long-term mechanical circulatory support or heart transplantation.

    Science.gov (United States)

    Shankar, Venkat; Costello, John P; Peer, Syed M; Klugman, Darren; Nath, Dilip S

    2014-04-01

    The use of extracorporeal membrane oxygenation (ECMO) in terminally ill pediatric patients who are not candidates for long-term mechanical circulatory support or heart transplantation requires careful deliberation. We present the case of a 16-year-old female with a relapse of acute lymphoid leukemia and acute-on-chronic cardiomyopathy who received short-term ECMO therapy. In addition, we highlight several ethical considerations that were crucial to this patient's family-centered care and demonstrate that this therapy can be accomplished in a manner that respects patient autonomy and family wishes.

  3. Influence of singlet oxygen (1O2) generated by a lipophilic photosensitizer (Pyropheophorbide-a, PPa) on membrane and firing properties of cultured hippocampus neurons

    DEFF Research Database (Denmark)

    Breitenbach, Thomas; Ogilby, Peter Remsen; Lambert, John D. C.

    2008-01-01

    . The spiking pattern was altered significantly, reflected by changes in spike threshold, frequency and tendency for fast APs to be followed by a plateau phase. These effects were correlated with the intensity and/or duration of illumination. Since we have previously documented that the lifetime and diffusion...... range of singlet oxygen are very small, its effects will be restricted. The intra-membrane generated 1O2 alters the composition of the lipid and also proteins or channels. This is reflected both in the immediate response to low irradiation-dose and in formation of long plateaus, which could be caused...

  4. Veno-arterial extracorporeal membrane oxygenation as a bridge for enabling surgery in a patient under cardiogenic shock due to acute mitral prosthesis dysfunction

    Directory of Open Access Journals (Sweden)

    María Elena Arnáiz-García

    2018-04-01

    Full Text Available A 52-year-old male patient, who underwent mitral replacement with a mechanical prosthesis as a child, sustained a cardiac arrest which was successfully resuscitated. Further investigation showed prosthesis malfunction with significant regurgitation in the context of multi-organ failure. In such a life-threatening condition, veno-arterial extracorporeal membrane oxygenation was considered as a rescue procedure to achieve optimisation of clinical status to allow definitive surgical treatment. An unusual complete fracture of the prosthesis was subsequently identified as the cause of acute dysfunction. Keywords: VA-ECMO, Mitral, Prosthesis, Dysfunction, Cardiogenic shock

  5. Oxygen transport properties of tubular Ce0.9Gd0.1O1.95-La0.6Sr0.4FeO3−d composite asymmetric oxygen permeation membranes supported on magnesium oxide

    DEFF Research Database (Denmark)

    Ovtar, Simona; Gurauskis, Jonas; Bjørnetun Haugen, Astri

    2017-01-01

    The oxygen permeation through dense Ce0.9Gd0.1O1.95-La0.6Sr0.4FeO3−d  dual-phase composite asymmetric membranes supported on a porous MgO tube was studied. The membranes were prepared by thermoplastic extrusion, dip coating, co-sintering and infiltration of a catalyst. Oxygen permeation measureme...

  6. A novel ion transport membrane reactor for fundamental investigations of oxygen permeation and oxy-combustion under reactive flow conditions

    KAUST Repository

    Kirchen, Patrick; Apo, Daniel J.; Hunt, Anton; Ghoniem, Ahmed F.

    2013-01-01

    Ion transport membrane (ITM) reactors present an attractive technology for combined air separation and fuel conversion in applications such as syngas production, oxidative coupling or oxy-combustion, with the promise of lower capital and operating

  7. Electronic and ionic transport in Ce0.8PrxTb0.2-xO2-δ and evaluation of performance as oxygen permeation membranes

    DEFF Research Database (Denmark)

    Chatzichristodoulou, Christodoulos; Hendriksen, Peter Vang

    2012-01-01

    is significantly enhanced relative to that of a Ce0.9Gd0.1O1.95-δ membrane at high oxygen activities of the permeate gas (aO2 an > 10-15) due to the enhanced electronic conductivity of the Ce0.8PrxTb0.2-xO2-δ compounds. Interference between the ionic and electronic flows has a significant positive effect......The electronic conductivity of Ce0.8PrxTb0.2-xO2-δ (x = 0, 0.05, 0.10, 0.15, 0.20) was determined in the oxygen activity range aO2 ≈ 103 to aO2 ≈ 10-17 at 700- 900 °C by means of Hebb-Wagner polarisation. The electronic conductivity of all the Ce0.8PrxTb0.2-xO2-δ compositions was significantly...... enhanced as compared to that of Ce0.9Gd0.1O1.95-δ, and its value was found to increase with increasing Pr/Tb ratio. The ionic mobility of Ce0.8PrxTb0.2-xO2-δ is similar to that of Ce1- 2δGd2δO2-δ at the same oxygen vacancy concentration. The calculated oxygen flux of a Ce0.8PrxTb0.2-xO2-δ membrane...

  8. Oxygen transport and degradation properties of high-temperature membranes for CO{sub 2}-free power plants; Sauerstofftransport und Degradationsverhalten von Hochtemperaturmembranen fuer CO{sub 2}-freie Kraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Schlehuber, Dominic

    2010-07-01

    This thesis deals with membranes for oxygen separation from air for high temperature application in fossil power plants within the scope of the oxyfuel-process. Different perovskite membrane materials (ABO3-ae) were investigated concerning the oxygen transport and their chemical stability under operation condition. The association between oxygen transport properties and both the thermodynamic boundary conditions as well as the material properties (membrane thickness and surface properties) was studied. One possibility to achieve higher oxygen fluxes through the membrane is to reduce the thickness. In this case the influence of surface processes on the overall permeation becomes noteworthy. The effect of different membrane surface modifications on the permeation rate was investigated. For example it could be confirmed, that a porous layer on the membrane surface significantly increases the permeation flux due to the compensation of surface exchange limitations. Beyond that, degradation processes during the operation under power plant condition were investigated. Special attention was attached to the influence of degradation on the permeation flux during long term operation. Thereby kinetic demixing of the membrane material was observed. (orig.)

  9. Promising monolayer membranes for CO{sub 2}/N{sub 2}/CH{sub 4} separation: Graphdiynes modified respectively with hydrogen, fluorine, and oxygen atoms

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Lianming, E-mail: lmzhao@upc.edu.cn; Sang, Pengpeng; Guo, Sheng; Liu, Xiuping; Li, Jing; Zhu, Houyu; Guo, Wenyue, E-mail: wyguo@upc.edu.cn

    2017-05-31

    Graphical abstract: Graphdiyne monolayer membrane modified by fluorine or oxygen can effectively separate CO{sub 2}/N{sub 2}/CH{sub 4} mixtures. - Highlights: • Three graphdiyne-like membranes were designed and their stabilities were confirmed. • The DFT and MD results claimed a tunable gas separation property of the membranes. • Graphdiyne modified with F or O can effectively separate CO{sub 2}/N{sub 2}/CH{sub 4} mixtures. - Abstract: Three graphdiyne-like monolayers were designed by substituting one-third diacetylenic linkages with heteroatoms hydrogen, fluorine, and oxygen (GDY-X, X = H, F, and O), respectively. The CO{sub 2}/N{sub 2}/CH{sub 4} separation performance of the designed graphdiyne-like monolayers was investigated by using both first-principle density functional theory (DFT) and molecular dynamic (MD) simulations. The stabilities of GDY-X monolayers were confirmed by the calculated cohesive energies and phonon dispersion spectra. Both the DFT and MD calculations demonstrated that although the GDY-H membrane has poor selectivity for CO{sub 2}/N{sub 2}/CH{sub 4} gases, the GDY-F and GDY-O membranes can excellently separate CO{sub 2} and N{sub 2} from CH{sub 4} in a wide temperature range. Moreover, the CO{sub 2}/N{sub 2} mixture can be effectively separated by GDY-O at temperatures lower than 300 K. Based on the kinetic theory, extremely high permeances were found for CO{sub 2} and N{sub 2} passing through the GDY-X membranes (10{sup −4}–10{sup −2} mol/m{sup 2} s Pa at 298 K). In addition, the influence of relative concentration on selectivity was also investigated for gases in the binary mixtures. This work provides an effective way to modify graphdiyne for the separation of large molecular gases, which is quite crucial in the gas separation industry.

  10. Free-flow electrophoresis of plasma membrane vesicles enriched by two-phase partitioning enhances the quality of the proteome from Arabidopsis seedlings

    DEFF Research Database (Denmark)

    de Michele, Roberto; McFarlane, Heather E; Parsons, Harriet Tempé

    2016-01-01

    The plant plasma membrane is the interface between the cell and its environment undertaking a range of important functions related to transport, signaling, cell wall biosynthesis, and secretion. Multiple proteomic studies have attempted to capture the diversity of proteins in the plasma membrane...... using biochemical fractionation techniques. In this study, two-phase partitioning was combined with free-flow electrophoresis to produce a population of highly purified plasma membrane vesicles that were subsequently characterized by tandem mass spectroscopy. This combined high-quality plasma membrane...... isolation technique produced a reproducible proteomic library of over 1000 proteins with an extended dynamic range including plasma membrane-associated proteins. The approach enabled the detection of a number of putative plasma membrane proteins not previously identified by other studies, including...

  11. A proposed agglomerate model for oxygen reduction in the catalyst layer of proton exchange membrane fuel cells

    International Nuclear Information System (INIS)

    Zhang, Xiaoxian; Gao, Yuan; Ostadi, Hossein; Jiang, Kyle; Chen, Rui

    2014-01-01

    Highlights: • We developed a new agglomerate model to describe oxygen reduction reaction. • We showed how to calculate the model parameters from catalyst layer structure. • We verified the agglomerate model. - Abstract: Oxygen diffusion and reduction in the catalyst layer of PEM fuel cell is an important process in fuel cell modelling, but models able to link the reduction rate to catalyst-layer structure are lack; this paper makes such an effort. We first link the average reduction rate over the agglomerate within a catalyst layer to a probability that an oxygen molecule, which is initially on the agglomerate surface, will enter and remain in the agglomerate at any time in the absence of any electrochemical reaction. We then propose a method to directly calculate distribution function of this probability and apply it to two catalyst layers with contrasting structures. A formula is proposed to describe these calculated distribution functions, from which the agglomerate model is derived. The model has two parameters and both can be independently calculated from catalyst layer structures. We verify the model by first showing that it is an improvement and able to reproduce what the spherical model describes, and then testing it against the average oxygen reductions directly calculated from pore-scale simulations of oxygen diffusion and reaction in the two catalyst layers. The proposed model is simple, but significant as it links the average oxygen reduction to catalyst layer structures, and its two parameters can be directly calculated rather than by calibration

  12. 'Pre-prosthetic use of poly(lactic-co-glycolic acid) membranes treated with oxygen plasma and TiO2 nanocomposite particles for guided bone regeneration processes'.

    Science.gov (United States)

    Castillo-Dalí, Gabriel; Castillo-Oyagüe, Raquel; Terriza, Antonia; Saffar, Jean-Louis; Batista-Cruzado, Antonio; Lynch, Christopher D; Sloan, Alastair J; Gutiérrez-Pérez, José-Luis; Torres-Lagares, Daniel

    2016-04-01

    Guided bone regeneration (GBR) processes are frequently necessary to achieve appropriate substrates before the restoration of edentulous areas. This study aimed to evaluate the bone regeneration reliability of a new poly-lactic-co-glycolic acid (PLGA) membrane after treatment with oxygen plasma (PO2) and titanium dioxide (TiO2) composite nanoparticles. Circumferential bone defects (diameter: 10mm; depth: 3mm) were created on the parietal bones of eight experimentation rabbits and were randomly covered with control membranes (Group 1: PLGA) or experimental membranes (Group 2: PLGA/PO2/TiO2). The animals were euthanized two months afterwards, and a morphologic study was then performed under microscope using ROI (region of interest) colour analysis. Percentage of new bone formation, length of mineralised bone formed in the grown defects, concentration of osteoclasts, and intensity of osteosynthetic activity were assessed. Comparisons among the groups and with the original bone tissue were made using the Kruskal-Wallis test. The level of significance was set in advance at a=0.05. The experimental group recorded higher values for new bone formation, mineralised bone length, and osteoclast concentration; this group also registered the highest osteosynthetic activity. Bone layers in advanced formation stages and low proportions of immature tissue were observed in the study group. The functionalised membranes showed the best efficacy for bone regeneration. The addition of TiO2 nanoparticles onto PLGA/PO2 membranes for GBR processes may be a promising technique to restore bone dimensions and anatomic contours as a prerequisite to well-supported and natural-appearing prosthetic rehabilitations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Targeting the expression of glutathione- and sulfate-dependent detoxification enzymes in HepG2 cells by oxygen in minimal and amino acid enriched medium.

    Science.gov (United States)

    Usarek, Ewa; Graboń, Wojciech; Kaźmierczak, Beata; Barańczyk-Kuźma, Anna

    2016-02-01

    Cancer cells exhibit specific metabolism allowing them to survive and proliferate in various oxygen conditions and nutrients' availability. Hepatocytes are highly active metabolically and thus very sensitive to hypoxia. The purpose of the study was to investigate the effect of oxygen on the expression of phase II detoxification enzymes in hepatocellular carcinoma cells (HepG2) cultured in minimal and rich media (with nonessential amino acids and GSH). The cells were cultured at 1% hypoxia, 10% tissue normoxia, and 21% atmospheric normoxia. The total cell count was determined by trypan blue exclusion dye and the expression on mRNA level by RT-PCR. The result indicated that the expression of glutathione-dependent enzymes (GSTA, M, P, and GPX2) was sensitive to oxygen and medium type. At 1% hypoxia the enzyme expression (with the exception of GSTA) was higher in minimal compared to rich medium, whereas at 10% normoxia it was higher in the rich medium. The expression was oxygen-dependent in both types of medium. Among phenol sulfotransferase SULT1A1 was not sensitive to studied factors, whereas the expression of SULT1A3 was depended on oxygen only in minimal medium. It can be concluded that in HepG2 cells, the detoxification by conjugation with glutathione and, to a lower extent with sulfate, may be affected by hypoxia and/or limited nutrients' availability. Besides, because the data obtained at 10% oxygen significantly differ from those at 21%, the comparative studies on hypoxia should be performed in relation to 10% but not 21% oxygen. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Amperometric NOx-sensor for Combustion Exhaust Gas Control. Studies on transport properties and catalytic activity of oxygen permeable ceramic membranes

    International Nuclear Information System (INIS)

    Romer, E.W.J.

    2001-01-01

    The aim of the research described in this thesis is the development of a mixed conducting oxide layer, which can be used as an oxygen permselective membrane in an amperometric NOx sensor. The sensor will be used in exhaust gas systems. The exhaust gas-producing engine will run in the lean mix mode. The preparation of this sensor is carried out using screen-printing technology, in which the different layers of the sensor are applied successively. Hereafter, a co-firing step is applied in which all layers are sintered together. This co-firing step imposes several demands on the selection of materials. The design specifications of the sensor further include requirements concerning the operating temperature, measurement range and overall stability. The operating temperature of the sensor varies between 700 and 850C, enabling measurement of NOx concentrations between 50 and 1200 ppm with a measurement accuracy of 10 ppm. Concerning the stability of the sensor, it must withstand the exhaust gas atmosphere containing, amongst others, smoke, acids, abrasive particles and sulphur. Because of the chosen lean-mix engine concept, in which the fuel/air mixture switches continuously between lean (excess oxygen) and fat (excess fuel) mixtures, the sensor must withstand alternately oxidising and reducing atmospheres. Besides, it should be resistant to thermal shock and show no cross-sensitivity of NOx with other exhaust gas constituents like oxygen and hydrocarbons. The response time should be short, typically less than 500 ms. Because of the application in combustion engines of cars, the operational lifetime should be longer than 10 years. Demands on the mixed conducting oxide layer include the following ones. The layer should show minimal catalytic activity towards NOx-reduction. The oxygen permeability must be larger than 6.22 10 -8 mol/cm 2 s at a layer thickness between 3-50 μm. Since the mixed conducting oxide layer is coated on the YSZ electrolyte embodiment, the two

  15. Fabrication and characterization of cubic Ba{sub 0.5}Sr{sub 0.5}Co{sub 0.8}Fe{sub 0.2}O{sub 3−δ} perovskite for a novel “star-shaped” oxygen membrane with a developed surface

    Energy Technology Data Exchange (ETDEWEB)

    Borhan, Adrian Iulian [Institute of Power Engineering, Ceramic Department CEREL, Research Institute, 1 Techniczna St., 36-040 Boguchwała (Poland); Gromada, Magdalena, E-mail: gromada@cerel.pl [Institute of Power Engineering, Ceramic Department CEREL, Research Institute, 1 Techniczna St., 36-040 Boguchwała (Poland); Samoila, Petrisor [Petru Poni Institute of Macromolecular Chemistry, 41A, Gr. Ghica Voda Alley, 700487 Iasi (Romania); Gherca, Daniel [Alexandru Ioan Cuza University of Iasi, Faculty of Chemistry, 11 Carol 1 Boulevard, R-700506 Iasi (Romania)

    2016-07-15

    Highlights: • Innovative fabrication technology was elaborated for BSCF membrane with developed surface. • The tool for membranes forming with developed surface was designed and execu