  1. Design of pulse oximetry signal based on personal computer for detection oxygen saturation

    International Nuclear Information System (INIS)

    Umi Salamah; Margi Sasono

    2015-01-01

    The lack or excess of oxygen in the blood will cause healthy and body system disorder. At certain level, the disease can lead to death. For that reason, the information about oxygen saturation in blood becomes important to be identified. One of the devices used to monitor the blood oxygen saturation is pulse oximetry. This research attempt to designed Pulse Oximetry based on personal computer using red LED and infrared as its light source, while the light sensor using photodiode. The designed Pulse Oximetry is a non-invasive instrumentation which LED drivers is placed on the fingertips. The LED light goes through the finger will be a signal that is fed to the photodiode and will be converted into digital signals by ADC (Analog to Digital Converter) and will be processed further by a personal computer to display the pulse oximetry graphics. This study uses Delphi 7, Microsoft Excel, and Mt Lab as its software.This designed pulse oximetry has been tested in two peoples: sample A, male 38 years; and sample B, a woman 23 years old. Oxygen saturation of sample A is 80.75, while the sample B is 90.75. (author)

  2. Reliable monitoring of oxygen saturation via pulse oximetry: Which ...

    African Journals Online (AJOL)

    This study focuses on identifying the best site for placement of pulse oximeter probe accurate measuring of oxygen saturation. Twenty-three healthy male volunteers aged 20 to 40 years old were recruited in this study. Cold pressor test was done to stim 460 measurements of SpO2level were obtained throughout the study.

  3. Assessment of Arterial Oxygen Saturation by Pulse Oximetry Before, During and After Electroconvulsive Therapy

    Directory of Open Access Journals (Sweden)

    SH Tarig

    2006-07-01

    Full Text Available Introduction & Objective: Electroconvulsive therapy (ECT is used widely in psychiatric practice. The goal of anesthesia for ECT is the prevention of complications such as discomfort, fractures, aspiration of gastric contents and hypoxia. However, general anesthesia can cause some adverse effects as hypoxia. Prevention and treatment of hypoxia is important due to its undesirable effects on seizure duration and cardiovascular system. This study was designed to detect the incidence and probable times of desaturation in patients receiving ECT. Materials & Methods: This prospective randomized clinical trial was carried out on 100 patients (18-50 y/o with ASA I or II who were scheduled for ECT. After pre-oxygenation and similar anesthesia induction the patients received ECT. The patients were ventilated by oxygen and face masked until the return of their spontaneous respiration with adequate tidal volume and respiratory rate. Then they were transferred to recovery room where there was no oxygen supplementation. Oxygen saturation was measured by a Nell core pulse oximeter and was recorded at six stages: before and after anesthesia induction, during ECT, after ECT, 5 minutes after entering recovery room and before leaving there. The data were analyzed by standard statistical tests using SPSS software Results: Data analysis revealed that desaturation was not noticed at any stage except for the 5th stage (5 minutes after entering recovery room, when 13% of patients developed Sao2% less than 90%. Also there was a significant difference between Sao2% of patients between this stage (5th and other stages (p<0.001. Conclusion: According to our findings, appropriate oxygen supplementation and pulse oximetry monitoring during recovery period after ECT can be recommend

  4. Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering

    Science.gov (United States)

    James, Jyotsna; Tiwari, Lokesh; Upadhyay, Pramod; Sreenivas, Vishnubhatla; Bhambhani, Vikas; Puliyel, Jacob M

    2006-01-01

    Background The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. Methods POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. Results The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. Conclusion Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method. PMID:16677394

  5. Comparison of oxygen saturation values and measurement times by pulse oximetry in various parts of the body.

    Science.gov (United States)

    Yönt, Gülendam Hakverdioğlu; Korhan, Esra Akin; Khorshid, Leyla

    2011-11-01

    The aim of this study, which included 40 patients, was to compare the values pulse oximetry and the measurement times in various regions of the body. Data were analyzed using intraclass correlation coefficient test and paired-sample test. The confidence power value was found to be .81 for the comparison of oxygen saturation values by arterial blood gas analysis and measurement by the forehead probe. It was found that the time for oxygen saturation measurement using the forehead probe was shorter than those using the finger and toe probes. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Performance evaluation of photoacoustic oximetry imaging systems using a dynamic blood flow phantom with tunable oxygen saturation

    Science.gov (United States)

    Vogt, William C.; Zhou, Xuewen; Andriani, Rudy; Wear, Keith A.; Garra, Brian S.; Pfefer, Joshua

    2018-02-01

    Photoacoustic Imaging (PAI) is an emerging technology with strong potential for broad clinical applications from breast cancer detection to cerebral monitoring due to its ability to compute maps of blood oxygen saturation (SO2) distribution in deep tissues using multispectral imaging. However, no well-validated consensus test methods currently exist for evaluating oximetry-specific performance characteristics of PAI devices. We have developed a phantombased flow system capable of rapid SO2 adjustment to serve as a test bed for elucidation of factors impacting SO2 measurement and quantitative characterization of device performance. The flow system is comprised of a peristaltic pump, membrane oxygenator, oxygen and nitrogen gas, and in-line oxygen, pH, and temperature sensors that enable real-time estimation of SO2 reference values. Bovine blood was delivered through breast-relevant tissue phantoms containing vessel-mimicking fluid channels, which were imaged using a custom multispectral PAI system. Blood was periodically drawn for SO2 measurement in a clinical-grade CO-oximeter. We used this flow phantom system to evaluate the impact of device parameters (e.g.,wavelength-dependent fluence corrections) and tissue parameters (e.g. fluid channel depth, blood SO2, spectral coloring artifacts) on oximetry measurement accuracy. Results elucidated key challenges in PAI oximetry and device design trade-offs, which subsequently allowed for optimization of system performance. This approach provides a robust benchtop test platform that can support PAI oximetry device optimization, performance validation, and clinical translation, and may inform future development of consensus test methods for performance assessment of photoacoustic oximetry imaging systems.

  7. Theoretical model for optical oximetry at the capillary level: exploring hemoglobin oxygen saturation through backscattering of single red blood cells

    Science.gov (United States)

    Liu, Rongrong; Spicer, Graham; Chen, Siyu; Zhang, Hao F.; Yi, Ji; Backman, Vadim

    2017-02-01

    Oxygen saturation (sO2) of red blood cells (RBCs) in capillaries can indirectly assess local tissue oxygenation and metabolic function. For example, the altered retinal oxygenation in diabetic retinopathy and local hypoxia during tumor development in cancer are reflected by abnormal sO2 of local capillary networks. However, it is far from clear whether accurate label-free optical oximetry (i.e., measuring hemoglobin sO2) is feasible from dispersed RBCs at the single capillary level. The sO2-dependent hemoglobin absorption contrast present in optical scattering signal is complicated by geometry-dependent scattering from RBCs. We present a numerical study of backscattering spectra from single RBCs based on the first-order Born approximation, considering practical factors: RBC orientations, size variation, and deformations. We show that the oscillatory spectral behavior of RBC geometries is smoothed by variations in cell size and orientation, resulting in clear sO2-dependent spectral contrast. In addition, this spectral contrast persists with different mean cellular hemoglobin content and different deformations of RBCs. This study shows for the first time the feasibility of, and provides a theoretical model for, label-free optical oximetry at the single capillary level using backscattering-based imaging modalities, challenging the popular view that such measurements are impossible at the single capillary level.

  8. Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes.

    Science.gov (United States)

    Seifi, Sohila; Khatony, Alireza; Moradi, Gholamreza; Abdi, Alireza; Najafi, Farid

    2018-01-01

    Heart surgery patients are more at risk of poor peripheral perfusion, and peripheral capillary oxygen saturation (SpO2) measurement is regular care for continuous analysis of blood oxygen saturation in these patients. With regard to controversial studies on accuracy of the current pulse oximetry probes and lack of data related to patients undergoing heart surgery, the present study was conducted to determine accuracy of pulse oximetry probes of finger, toe, forehead and earlobe in detection of oxygen saturation in patients admitted to intensive care units for coronary artery bypass surgery. In this clinical trial, 67 patients were recruited based on convenience sampling method among those admitted to intensive care units for coronary artery bypass surgery. The SpO2 value was measured using finger, toe, forehead and earlobe probes and then compared with the standard value of arterial oxygen saturation (SaO2). Data were entered into STATA-11 software and analyzed using descriptive, inferential and Bland-Altman statistical analyses. Highest and lowest correlational mean values of SpO2 and SaO2 were related to finger and earlobe probes, respectively. The highest and lowest agreement of SpO2 and SaO2 were related to forehead and earlobe probes. The SpO2 of earlobe probes due to lesser mean difference, more limited confidence level and higher agreement ration with SaO2 resulted by arterial blood gas (ABG) analysis had higher accuracy. Thus, it is suggested to use earlobe probes in patients admitted to the intensive care unit for coronary artery bypass surgery. Registration of this trial protocol has been approved in Iranian Registry of Clinical Trials at 2018-03-19 with reference IRCT20100913004736N22. "Retrospectively registered."

  9. New hybrid reflectance optical pulse oximetry sensor for lower oxygen saturation measurement and for broader clinical application

    Science.gov (United States)

    Nogawa, Masamichi; Ching, Chong Thong; Ida, Takeyuki; Itakura, Keiko; Takatani, Setsuo

    1997-06-01

    A new reflectance pulse oximeter sensor for lower arterial oxygen saturation (Sa)2) measurement has been designed and evaluated in animals prior to clinical trials. The new sensor incorporates ten light emitting diode chips for each wavelength of 730 and 880 nm mounted symmetrically and at the radial separation distance of 7 mm around a photodiode chip. The separation distance of 7 mm was chosen to maximize the ratio of the pulsatile to the average plethysmographic signal level at each wavelength. The 730 and 880 wavelength combination was determined to obtain a linear relationship between the reflectance ratio of the 730 and 880 nm wavelengths and Sa)2. In addition to these features of the sensor, the Fast Fourier Transform method was employed to compute the pulsatile and average signal level at each wavelength. The performance of the new reflectance pulse oximeter sensor was evaluated in dogs in comparison to the 665/910 nm sensor. As predicted by the theoretical simulation based on a 3D photon diffusion theory, the 730/880 nm sensor demonstrated an excellent linearity over the SaO2 range from 100 to 30 percent. For the SaO2 range between 100 and 70 percent, the 665/910 and 730/880 sensors showed the standard error of around 3.5 percent and 2.1 percent, respectively, in comparison to the blood samples. For the range between 70 and 30 percent, the standard error of the 730/880 nm sensor was only 2.7 percent, while that of the 665/910 nm sensor was 9.5 percent. The 730/880 sensor showed improved accuracy for a wide range of SaO2 particularly over the range between 70 and 30 percent. This new reflectance sensor can provide noninvasive measurement of SaO2 accurately over the wide saturation range from 100 to 30 percent.

  10. Pulse Oximetry for the Detection of Obstructive Sleep Apnea Syndrome: Can the Memory Capacity of Oxygen Saturation Influence Their Diagnostic Accuracy?

    Directory of Open Access Journals (Sweden)

    Carlos A. Nigro

    2011-01-01

    Full Text Available Objective. To assess the diagnostic ability of WristOx 3100 using its three different recording settings in patients with suspected obstructive sleep apnea syndrome (OSAS. Methods. All participants (135 performed the oximetry (three oximeters WristOx 3100 and polysomnography (PSG simultaneously in the sleep laboratory. Both recordings were interpreted blindly. Each oximeter was set to one of three different recording settings (memory capabilities 0.25, 0.5, and 1 Hz. The software (nVision 5.1 calculated the adjusted O2 desaturation index-mean number of O2 desaturation per hour of analyzed recording ≥2, 3, and 4% (ADI2, 3, and 4. The ADI2, 3, and 4 cutoff points that better discriminated between subjects with or without OSAS arose from the receiver-operator characteristics (ROCs curve analysis. OSAS was defined as a respiratory disturbance index (RDI ≥ 5. Results. 101 patients were included (77 men, mean age 52, median RDI 22.6, median BMI 27.4 kg/m2. The area under the ROCs curves (AUC-ROCs of ADI2, 3, and 4 with different data storage rates were similar (AUC-ROCs with data storage rates of 0.25/0.5/1 Hz: ADI2: 0.958/0.948/0.965, ADI3: 0.961/0.95/0.966, and ADI4: 0.957/0.949/0.963, P NS. Conclusions. The ability of WristOx 3100 to detect patients with OSAS was not affected by the data storage rate of the oxygen saturation signal. Both memory capacity of 0.25, 0.5, or 1 Hz showed a similar performance for the diagnosis of OSAS.

  11. Independent component analysis applied to pulse oximetry in the estimation of the arterial oxygen saturation (SpO2) - a comparative study

    DEFF Research Database (Denmark)

    Jensen, Thomas; Duun, Sune Bro; Larsen, Jan

    2009-01-01

    We examine various independent component analysis (ICA) digital signal processing algorithms for estimating the arterial oxygen saturation (SpO2) as measured by a reflective pulse oximeter. The ICA algorithms examined are FastICA, Maximum Likelihood ICA (ICAML), Molgedey and Schuster ICA (ICAMS......), and Mean Field ICA (ICAMF). The signal processing includes pre-processing bandpass filtering to eliminate noise, and post-processing by calculating the SpO2. The algorithms are compared to the commercial state-of-the-art algorithm Discrete Saturation Transform (DST) by Masimo Corporation...

  12. Oxygen general saturation after bronchography under general ...

    African Journals Online (AJOL)

    Thirty-six patients undergoing bronchography or bronchoscopy under general anaesthesia were continuously monitored by pulse oximetry for 5 hours after these procedures. Significant falls in oxygen saturation were observed in the first hour and were of most clinical relevance in patients with preexisting pulmonary ...

  13. TECHNIQUES OF EVALUATION OF HEMOGLOBIN OXYGEN SATURATION IN CLINICAL OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2016-01-01

    Full Text Available Oxygen content in body fluids and tissues is an important indicator of life support functions. A number of ocular pathologies, e.g. glaucoma, are of presumable vascular origin which means altered blood supply and oxygen circulation. Most oxygen is transported in the blood in the association with hemoglobin. When passing through the capillaries, hemoglobin releases oxygen, converting from oxygenated form to deoxygenated form. This process is accompanied by the changes in spectral characteristics of hemoglobin which result in different colors of arterial and venous blood. Photometric technique for the measurement of oxygen saturation in blood is based on the differences in light absorption by different forms of hemoglobin. The measurement of saturation is called oximetry. Pulse oximetry with assessment of tissue oxygenation is the most commonly used method in medicine. The degree of hemoglobin oxygen saturation in the eye blood vessels is the most accessible for noninvasive studies during ophthalmoscopy and informative. Numerous studies showed the importance of this parameter for the diagnosis of retinopathy of various genesis, metabolic status analysis in hyperglycemia, diagnosis and control of treatment of glaucoma and other diseases involving alterations in eye blood supply. The specific method for evaluation of oxygen concentration is the measurement of pressure of oxygen dissolved in the blood, i.e. partial pressure of oxygen. In ophthalmological practice, this parameter is measured in anterior chamber fluid evaluating oxygen level for several ophthalmopathies including different forms of glaucoma, for instillations of hypotensive eye drops as well as in vitreous body near to the optic disc under various levels of intraocular pressure. Currently, monitoring of oxygen saturation in retinal blood vessels, i.e. retinal oximetry, is well developed. This technique is based on the assessment of light absorption by blood depending on

  14. Rejection of Erroneous Saturation Data in Optical Pulse Oximetry in Newborn Patients

    Science.gov (United States)

    Scalise, L.; Marchionni, Paolo; Carnielli, Virgilio P.

    2011-08-01

    Pulse oximetry (PO) is extensively used in intensive care unit (ICU); this is mainly due to the fact that it is a non-invasive and real-time monitoring method. PO allows to measure arterial oxygen saturation (SaO2) and in particular hemoglobin oxygenation. Optical PO is typically realized by the use of a clip (to be applied on the ear or on the finger top) containing a couple of monochromatic LED sources and a photodiode. The main drawback with the use of PO is the presence of movement artifacts or disturbance due to optical sources and skin, causing erroneous saturation data. The aim of this work is to present the measurement procedure based on a specially developed algorithm able to reject erroneous oxygen saturation data during long lasting monitoring of patients in ICU and to compare measurement data with reference data provided by EGA. We have collected SaO2 data from a standard PO and used an intensive care unit monitor to collect data. This device was connected to our acquisition system and heart rate (HR) and SaO2 data were acquired and processed by our specially developed algorithm and directly reproduced on the PC screen for use by the clinicians. The algorithm here used for the individuation and rejection of erroneous saturation data is based on the assessment of the difference between the Heart Rate (HR) measured by respectively by the ECG and PO. We have used an emogasanalyzer (EGA) for comparison of the measured data. The study was carried out in a neonatal intensive care unit (NICU), using 817 data coming from 24 patients and the observation time was of about 10000 hours. Results show a reduction in the maximum difference between the SaO2 data measured, simultaneously, on the same patient by the EGA and by the proposed method of 14.20% and of the 4.76% in average over the 817 samples. The measurement method proposed is therefore able to individuate and eliminate the erroneous saturation data due to motion artifacts and reported by the pulse oxymeter

  15. Misconceptions in Reporting Oxygen Saturation

    NARCIS (Netherlands)

    Toffaletti, John; Zijlstra, Willem G.

    2007-01-01

    BACKGROUND: We describe some misconceptions that have become common practice in reporting blood gas and cooximetry results. In 1980, oxygen saturation was incorrectly redefined in a report of a new instrument for analysis of hemoglobin (Hb) derivatives. Oxygen saturation (sO(2)) was redefined as the

  16. The evaluation of cerebral oxygenation by oximetry in patients with ischaemic stroke.

    Directory of Open Access Journals (Sweden)

    Demet G

    2000-04-01

    Full Text Available AIMS: To evaluate the clinical significance of estimation of the regional cerebral oxygen saturation (rSO2 in the patients with ischaemic stroke by the cerebral oximetry during acute, sub-acute and chronic phases. SUBJECTS AND METHODS: In this prospective study, 24 patients with ischaemic stroke in the middle cerebral artery territory were included. A detailed clinical examination and appropriate laboratory investigations were carried out. The rSO2 was determined by oximetery (INVOS 3100-SD bilaterally on the first, third, seventh, and fifteenth days. The blood pressure, the peripheral capillary oxygen saturation and the arterial blood gas values were noted too. the changes were evaluated along with Glasgow coma scale (GCS using unpaired student t-test and one way ANOVA test. RESULTS: There were significant differences between the rSO2 values in acute, subacute and chronic phases on the side of the lesion (p value < 0.05. The values of oxygen saturation gradually increased throughout the chronic phase. These values showed a positive correlation with GCS, but the results were not significant statistically. The rSO2 values were also significantly higher on the non-lesional side than those on the lesion side in the acute phase (p= 0.0034, the discrepancy disappeared during the sub-acute and chronic phases. CONCLUSION: Cerebral oximetry can be used as a measure to evaluate the cerebral oxygenation during the various phases of ischaemic stroke. It has a potential to serve as a useful marker for detection of cerebral oxygenation imbalances, to judge the effectiveness of the management and for the follow-up of patients with ischaemic stroke.

  17. The relation between oxygen saturation level and retionopathy of prematurity

    Directory of Open Access Journals (Sweden)

    Mohammad Gharavi Fard

    2016-03-01

    Full Text Available Introduction: Oxygen therapy used for preterm infant disease might be associated with oxygen toxicity or oxidative stress. The exact oxygen concentration to control and maintain the arterial oxygen saturation balance is not certainly clear. We aimed to compare the efficacy of higher or lower oxygen saturations on the development of severe retinopathy of prematurity which is a major cause of blindness in preterm neonates. Methods: PubMed was searched for obtaining the relevant articles. A total of seven articles were included after studying the titles, abstracts, and the full text of retrieved articles at initial search. Inclusion criteria were all the English language human clinical randomized controlled trials with no time limitation, which studied the efficacy of low versus high oxygen saturation measured by pulse oximetry in preterm infants.Result: It can be suggested that lower limits of oxygen saturations have higher efficacy at postmesetural age of ≤28 weeks in preterm neonates. This relation has been demonstrated in five large clinical trials including three Boost trials, COT, and Support.Discussion: Applying higher concentrations of oxygen supplementations at mesentural age ≥32 weeks reduced the development of retinopathy of prematurity. Lower concentrations of oxygen saturation decreased the incidence and the development of retinopathy of prematurity in preterm neonates while applied soon after the birth.Conclusions: Targeting levels of oxygen saturation in the low or high range should be performed cautiously with attention to the postmesentural age in preterm infants at the time of starting the procedures.

  18. Spectrophotometric retinal oximetry in pigs

    DEFF Research Database (Denmark)

    Traustason, Sindri; Kiilgaard, Jens Folke; Karlsson, Robert

    2013-01-01

    PURPOSE: To assess the validity of spectrophotometric retinal oximetry, by comparison to blood gas analysis and intra-vitreal measurements of partial pressure of oxygen (pO2). METHODS: Female domestic pigs were used for all experiments (n=8). Oxygen fraction in inspired air was changed using...... a mixture of room air, pure oxygen and pure nitrogen, ranging from 5% to 100% oxygen. Femoral arterial blood gas analysis and retinal oximetry was performed at each level of inspiratory oxygen fraction. Retinal oximetry was performed using a commercial instrument, the Oxymap Retinal Oximeter T1 (Oxymap ehf...... arterial oxygen saturation and the optical density ratio over retinal arteries revealed an approximately linear relationship (R(2) = 0.74, p = 3.4 x 10(-9)). In order to test the validity of applying the arterial calibration to veins, we compared non-invasive oximetry measurements to invasive pO2...

  19. Saturação de oxigênio fetal medida pela oximetria de pulso durante o trabalho de parto: relações com o ph da artéria umbilical Fetal oxygen saturation measured by pulse oximetry during labor: relation to umbilical artery pH

    Directory of Open Access Journals (Sweden)

    Edson Nunes de Morais

    1999-04-01

    Full Text Available Objetivos: estudar os níveis de saturação de oxigênio fetal (SpO2 durante o trabalho de parto pela técnica da oximetria de pulso e sua relação com o pH da artéria umbilical (AU. Pacientes e Métodos: a SpO2 fetal foi medida durante o parto por meio da técnica da oximetria de pulso em 50 casos. Comparou-se a média dos valores de SpO2 entre os dois períodos do trabalho de parto, sendo o primeiro subdividido em fases, segundo a dilatação cervical ( ou = 7,20 e ou = 30,0%. Resultados: as médias da SpO2 fetal no primeiro período do parto foram de 53,0 ± 7,3% e 44,2 ± 6,8%, e no segundo 46,8 ± 7,7% e 38,4 ± 7,1% (pH da AU > ou = 7,20 e ou = 7,20 foram de 55,1 ± 5,1% (Purpose: to study fetal oxygen saturation (SpO2 levels during labor by continuous pulse oximetry tecnique, and its relation to umbilical artery (UA pH. Patients and Methods: fetal SpO2 levels were measured during labor by the pulse oximetry technique in 50 subjects. Average values of SpO2 were compared between the first and second stage of labor, with the first stage further subdivided into phases, according to cervical dilatation of ( or = 7.20 and or = 30.0% was considered normal. Results: fetal SpO2 averages during the first stage were 53.0 ± 7.3% and 44.2 ± 6.8% (UA pH > or = 7.20 and or = 7.20 were 55.1 ± 5.1% (<=4 cm, 52.3 ± 4.6% (5-7 cm and 51.5 ± 7.2% (8-9 cm; for UA pH <7.20, the fetal SpO2 averages were 46.3 ± 5.1% (<=4 cm, 43.6 ± 6.7% (5-7 cm and 42.8 ± 5.8% (8-9 cm. Considering the UA pH, these differences were statistically significant (p<0.01. Conclusion: a significant decrease of oxygen saturation values was observed during labor when fetal pulse oximetry was used.

  20. Retrievable micro-inserts containing oxygen sensors for monitoring tissue oxygenation using EPR oximetry

    International Nuclear Information System (INIS)

    Dinguizli, M; Beghein, N; Gallez, B

    2008-01-01

    Tissue oxygenation is a crucial parameter in various physiopathological situations and can influence the therapeutic response of tumours. EPR oximetry is a reliable method for assessing and monitoring oxygen levels in vivo over long periods of time. Among the different paramagnetic oxygen sensors available for EPR oximetry, lithium phthalocyanine (LiPc) is a serious candidate for in vivo applications because of its narrow linewidth and its high signal-to-noise ratio. To enhance the biocompatibility of the sensors, fluoropolymer Teflon AF2400 was used to make cylindrical micro-inserts containing LiPc crystals. This new micro-pellet design has several advantages for in vivo studies, including the possibility of being able to choose the implant size, a high sensor content, the facility of in vivo insertion and complete protection with preservation of the oxygen sensor's characteristics. The response to oxygen and the kinetics of this response were tested using in vivo EPR: no differences were observed between micro-inserts and uncoated LiPc crystals. Pellets implanted in vivo in muscles conserved their responsiveness over a long period of time (∼two months), which is much longer than the few days of stability observed using LiPc crystals without protection by the implant. Finally, evaluation of the biocompatibility of the implants revealed no inflammatory reaction around the implantation area

  1. Assessment of oxygen saturation in dental pulp of permanent teeth with periodontal disease.

    Science.gov (United States)

    Giovanella, Larissa Bergesch; Barletta, Fernando Branco; Felippe, Wilson Tadeu; Bruno, Kely Firmino; de Alencar, Ana Helena Gonçalves; Estrela, Carlos

    2014-12-01

    In individuals with periodontal disease, dental pulp status should be determined before a treatment plan is made. Pulse oximeters are promising diagnostic tools to evaluate pulp vascularization. This study used pulse oximetry to determine the level of oxygen saturation in dental pulp of intact permanent teeth with periodontal attachment loss (PAL) and gingival recession (GR) and to evaluate the correlation between periodontal disease and level of oxygen saturation in the pulp. This study included 67 anterior teeth of 35 patients; all teeth showed intact crowns, PAL, a periodontal pocket (PP), and GR. The teeth underwent periodontal examination, cold and electric pulp testing, and pulse oximetry measurements. The Pearson correlation coefficient and a linear regression coefficient were calculated to evaluate the degree of correlation between periodontal disease markers (PAL, PP, and GR) and the level of oxygen saturation in dental pulp. These tests also evaluated possible associations between oxygen saturation and cold and electric pulp testing. PAL, PP, and GR had negative correlations with oxygen saturation in dental pulp. Conversely, no statistically significant association was found between oxygen saturation in dental pulp and the response to electric sensibility testing. Oxygen saturation was lower in the pulp of permanent teeth with PAL, PP, and GR, indicating that periodontal disease correlates with the level of oxygen saturation in the pulp. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve.

    Science.gov (United States)

    Collins, Julie-Ann; Rudenski, Aram; Gibson, John; Howard, Luke; O'Driscoll, Ronan

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content), saturation (S O2 ) and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin-oxygen dissociation curve, a graphical representation of the relationship between oxygen satur-ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the S O2 in blood from patients with normal pH and S O2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (S pO2 ) is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (S aO2 ) as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable S pO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  3. Relating oxygen partial pressure, saturation and content: the haemoglobin–oxygen dissociation curve

    Directory of Open Access Journals (Sweden)

    Julie-Ann Collins

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content, saturation (SO2 and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin–oxygen dissociation curve, a graphical representation of the relationship between oxygen satur­ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the SO2 in blood from patients with normal pH and SO2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (SpO2 is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (SaO2 as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable SpO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  4. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    International Nuclear Information System (INIS)

    Kyriacou, P A; Shafqat, K; Pal, S K

    2007-01-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO 2 ) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO 2 ) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO 2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  5. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Shafqat, K [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Pal, S K [St Andrew' s Centre for Plastic Surgery and Burns, Broomfield Hospital, Chelmsford, CM1 7ET (United Kingdom)

    2007-10-15

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO{sub 2}) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO{sub 2}) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO{sub 2} sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures

  6. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Science.gov (United States)

    Kyriacou, P. A.; Shafqat, K.; Pal, S. K.

    2007-10-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  7. High or low oxygen saturation and severe retinopathy of prematurity: a meta-analysis.

    Science.gov (United States)

    Chen, Minghua L; Guo, Lei; Smith, Lois E H; Dammann, Christiane E L; Dammann, Olaf

    2010-06-01

    Low oxygen saturation appears to decrease the risk of severe retinopathy of prematurity (ROP) in preterm newborns when administered during the first few weeks after birth. High oxygen saturation seems to reduce the risk at later postmenstrual ages (PMAs). However, previous clinical studies are not conclusive individually. To perform a systematic review and meta-analysis to report the association between severe ROP incidence of premature infants with high or low target oxygen saturation measured by pulse oximetry. Studies were identified through PubMed and Embase literature searches through May 2009 by using the terms "retinopathy of prematurity and oxygen" or "retinopathy of prematurity and oxygen therapy." We selected 10 publications addressing the association between severe ROP and target oxygen saturation measured by pulse oximetry. Using a random-effects model we calculated the summary-effect estimate. We visually inspected funnel plots to examine possible publication bias. Low oxygen saturation (70%-96%) in the first several postnatal weeks was associated with a reduced risk of severe ROP (risk ratio [RR]: 0.48 [95% confidence interval (CI): 0.31-0.75]). High oxygen saturation (94%-99%) at > or = 32 weeks' PMA was associated with a decreased risk for progression to severe ROP (RR: 0.54 [95% CI: 0.35-0.82]). Among preterm infants with a gestational age of large randomized clinical trial with long-term developmental follow-up is warranted to confirm this meta-analytic result.

  8. Retinal Vessel Oxygen Saturation during 100% Oxygen Breathing in Healthy Individuals.

    Directory of Open Access Journals (Sweden)

    Olof Birna Olafsdottir

    Full Text Available To detect how systemic hyperoxia affects oxygen saturation in retinal arterioles and venules in healthy individuals.Retinal vessel oxygen saturation was measured in 30 healthy individuals with a spectrophotometric retinal oximeter (Oxymap T1. Oximetry was performed during breathing of room air, 100% oxygen (10 minutes, 6L/min and then again room air (10 minutes recovery.Mean oxygen saturation rises modestly in retinal arterioles during 100% oxygen breathing (94.5%±3.8 vs. 92.0%±3.7% at baseline, p<0.0001 and dramatically in retinal venules (76.2%±8.0% vs. 51.3%±5.6%, p<0.0001. The arteriovenous difference decreased during 100% oxygen breathing (18.3%±9.0% vs. 40.7%±5.7%, p<0.0001. The mean diameter of arterioles decreased during 100% oxygen breathing compared to baseline (9.7±1.4 pixels vs. 10.3±1.3 pixels, p<0.0001 and the same applies to the mean venular diameter (11.4±1.2 pixels vs. 13.3±1.5 pixels, p<0.0001.Breathing 100% oxygen increases oxygen saturation in retinal arterioles and more so in venules and constricts them compared to baseline levels. The dramatic increase in oxygen saturation in venules reflects oxygen flow from the choroid and the unusual vascular anatomy and oxygen physiology of the eye.

  9. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriëtte; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michaël A.; Spronk, Peter E.

    2012-01-01

    Objective: The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design: Prospective observational controlled study. Setting: Nonacademic university-affiliated

  10. Nocturnal oxygen saturation profiles of healthy term infants.

    Science.gov (United States)

    Terrill, Philip Ian; Dakin, Carolyn; Hughes, Ian; Yuill, Maggie; Parsley, Chloe

    2015-01-01

    Pulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2 values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen saturation values from a prospective longitudinal cohort of healthy infants. Prospective longitudinal cohort study. Sleep-laboratory. 34 healthy term infants were enrolled, and studied at 2 weeks, 3, 6, 12 and 24 months of age (N=30, 25, 27, 26, 20, respectively). Full overnight polysomnography, including 2 s averaging pulse oximetry (Masimo Radical). Summary SpO2 statistics (mean, median, 5th and 10th percentiles) and SpO2 CF plots were calculated for each recording. CF reference-curves were then generated for each study age. Analyses were repeated with sleep-state stratifications and inclusion of manual artefact removal. Median nocturnal SpO2 values ranged between 98% and 99% over the first 2 years of life and the CF reference-curves shift right by 1% between 2 weeks and 3 months. CF reference-curves did not change with manual artefact removal during sleep and did not vary between rapid eye movement (REM) and non-REM sleep. Manual artefact removal did significantly change summary statistics and CF reference-curves during wake. SpO2 CF curves provide an intuitive visual tool for evaluating whether an individual's nocturnal SpO2 distribution falls within the range of healthy age-matched infants, thereby complementing summary statistics in the interpretation of extended oximetry recordings in infants. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Oximetry using multispectral imaging: theory and application

    Science.gov (United States)

    MacKenzie, Lewis E.; Harvey, Andrew R.

    2018-06-01

    Multispectral imaging (MSI) is a technique for measurement of blood oxygen saturation in vivo that can be applied using various imaging modalities to provide new insights into physiology and disease development. This tutorial aims to provide a thorough introduction to the theory and application of MSI oximetry for researchers new to the field, whilst also providing detailed information for more experienced researchers. The optical theory underlying two-wavelength oximetry, three-wavelength oximetry, pulse oximetry, and multispectral oximetry algorithms are described in detail. The varied challenges of applying MSI oximetry to in vivo applications are outlined and discussed, covering: the optical properties of blood and tissue, optical paths in blood vessels, tissue auto-fluorescence, oxygen diffusion, and common oximetry artefacts. Essential image processing techniques for MSI are discussed, in particular, image acquisition, image registration strategies, and blood vessel line profile fitting. Calibration and validation strategies for MSI are discussed, including comparison techniques, physiological interventions, and phantoms. The optical principles and unique imaging capabilities of various cutting-edge MSI oximetry techniques are discussed, including photoacoustic imaging, spectroscopic optical coherence tomography, and snapshot MSI.

  12. Oxygenation of saturated and unsaturated hydrocarbons with ...

    Indian Academy of Sciences (India)

    Unknown

    Oxygenation of saturated and unsaturated hydrocarbons with sodium periodate. 431. Table 1. Competitive oxygenation of tetralin and cyclooctene with sodium periodate catalyzed by different manga- .... Teacher Education University. My grateful thanks also extend to Dr D Mohajer for his useful sugges- tions. References. 1.

  13. Optimal oxygen saturation in premature infants

    Directory of Open Access Journals (Sweden)

    Meayoung Chang

    2011-09-01

    Full Text Available There is a delicate balance between too little and too much supplemental oxygen exposure in premature infants. Since underuse and overuse of supplemental oxygen can harm premature infants, oxygen saturation levels must be monitored and kept at less than 95% to prevent reactive oxygen species-related diseases, such as retinopathy of prematurity and bronchopulmonary dysplasia. At the same time, desaturation below 80 to 85% must be avoided to prevent adverse consequences, such as cerebral palsy. It is still unclear what range of oxygen saturation is appropriate for premature infants; however, until the results of further studies are available, a reasonable target for pulse oxygen saturation (SpO2 is 90 to 93% with an intermittent review of the correlation between SpO2 and the partial pressure of arterial oxygen tension (PaO2. Because optimal oxygenation depends on individuals at the bedside making ongoing adjustments, each unit must define an optimal target range and set alarm limits according to their own equipment or conditions. All staff must be aware of these values and adjust the concentration of supplemental oxygen frequently.

  14. Retinal oxygen saturation in relation to retinal thickness in diabetic macular edema

    DEFF Research Database (Denmark)

    Blindbæk, Søren Leer; Peto, Tunde; Grauslund, Jakob

    to retinal thickness in patients with diabetic macular edema (DME). Methods: We included 18 patients with DME that all had central retinal thickness (CRT) >300 µm and were free of active proliferative diabetic retinopathy. Optical coherence tomography (Topcon 3D OCT-2000 spectral domain OCT) was used...... for paracentral edema, the oxygen saturation in the upper and lower temporal arcade branches were compared to the corresponding upper and lower subfield thickness. Spearman’s rank was used to calculate correlation coefficients between CRT and retinal oximetry. Results: Median age and duration of diabetes was 59....... 92.3%, p=0.52). We found no correlation between CRT and retinal oxygen saturation, even when accounting for paracentral edema (p>0.05). Furthermore, there was no difference in retinal oxygen saturation between the macular hemisphere that was more or less affected by DME (p>0.05). Conclusion: Patients...

  15. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriette; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michael A.; Spronk, Peter E.

    2012-01-01

    Objective:  The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design:  Prospective observational controlled study. Setting:  Nonacademic university-affiliated

  16. Oxygen Saturation in the Dental Pulp of Maxillary Premolars in Different Age Groups - Part 1.

    Science.gov (United States)

    Estrela, Carlos; Serpa, Giuliano C; Alencar, Ana Helena G; Bruno, Kely F; Barletta, Fernando B; Felippe, Wilson T; Estrela, Cyntia R A; Souza, João B

    2017-01-01

    The aim of this study was to determine oxygen saturation levels in the dental pulp of maxillary premolars in different age groups. A total of 120 human maxillary premolars with normal dental pulps were selected covering the following age groups: 20-24, 25-29, 30-34, 35-39 and 40-44 years (n=24 each group). Oxygen saturation was assessed using pulse oximetry. Analysis of variance was used to assess differences in oxygen saturation levels and Tukey's test was used to identify the age groups that differed from each other. Significance was set at 0.05. Mean oxygen saturation of 120 premolars was 86.20% considering all age groups. Significantly reduced levels were found in the oldest group compared to the other groups: 40 to 44 years - 80.00% vs. 89.71, 87.67, 88.71, and 84.80% for age groups 20-24, 25-29, 30-34, 35-39 years, respectively. The mean oxygen saturation levels were similar between 20 and 39 years of age (86.20%) in the whole sample, but reduced significantly in the 40-44-year age group, suggesting that older patients present lower oxygen saturation results even in the absence of pulp tissue injury.

  17. A flexible infrared sensor for tissue oximetry

    DEFF Research Database (Denmark)

    Petersen, Søren Dahl; Thyssen, Anders; Engholm, Mathias

    2013-01-01

    We present a flexible infrared sensor for use in tissue oximetry with the aim of treating prematurely born infants. The sensor will detect the oxygen saturation in brain tissue through near infrared spectroscopy. The sensor itself consists of several individual silicon photo detectors fully...

  18. Oxygen saturation index and severity of hypoxic respiratory failure.

    Science.gov (United States)

    Rawat, Munmun; Chandrasekharan, Praveen K; Williams, Ashley; Gugino, Sylvia; Koenigsknecht, Carmon; Swartz, Daniel; Ma, Chang Xing; Mathew, Bobby; Nair, Jayasree; Lakshminrusimha, Satyan

    2015-01-01

    The oxygenation index (OI = mean airway pressure, MAP × FiO2 × 100 : PaO2) is used to assess the severity of hypoxic respiratory failure (HRF) and persistent pulmonary hypertension of the newborn (PPHN). An indwelling arterial line or arterial punctures are necessary to obtain PaO2 for the calculation of OI. Oxygenation can be continuously and noninvasively assessed using pulse oximetry. The use of the oxygen saturation index (OSI = MAP × FiO2 × 100 : SpO2) can be an alternate method of assessing the severity of HRF. To evaluate the correlation between OSI and OI in the following: (1) neonates with HRF and (2) a lamb model of meconium aspiration syndrome. Human neonates: a retrospective chart review of 74 ventilated late preterm/term neonates with indwelling arterial access and SpO2 values in the first 24 h of life was conducted. OSI and OI were calculated and correlated. Lamb model: arterial blood gases were drawn and preductal SpO2 was documented in 40 term newborn lambs with asphyxia and meconium aspiration. OI and OSI were calculated and correlated with pulmonary vascular resistance (PVR). Mean values of OSI and OI showed a correlation coefficient of 0.952 in neonates (mean value of 308 observations in 74 neonates) and 0.948 in lambs (mean value of 743 observations in 40 lambs). In lambs, with increasing PVR, there was a decrease in OI and OSI. OSI correlates significantly with OI in infants with HRF. This noninvasive measure may be used to assess the severity of HRF and PPHN in neonates without arterial access. © 2015 S. Karger AG, Basel

  19. Improvement in retinal venous oxygen saturation after panretinal photocoagulation is predictive of progression of proliferative diabetic retinopathy

    DEFF Research Database (Denmark)

    Torp, Thomas Lee; Kawasaki, Ryo; Wong, Tien Yin

    blood pressure was 152/84mmHg. Retinal arterial and venous saturation was 96.7% and 67.4%, respectively. Patients in Group 1 and 2 did not differ in baseline retinal arterial and venous oxygen saturation, number of laser spots delivered, total laser energy delivered, or change in retinal arterial oxygen...... patients with diagnosed PDR were included. We performed wide-field fluorescein angiography (WFA) (Optomap; Optos PLC., Dunfermline, Scotland, UK) and retinal oximetry (Oxymap model T1; Oxymap, software version 2.4.2, Reykjavik, Iceland) at baseline and three months after PRP by a navigated laser (NAVILAS...

  20. Comparison of pulseoximetry oxygen saturation and arterial oxygen saturation in open heart intensive care unit

    Directory of Open Access Journals (Sweden)

    Alireza Mahoori

    2013-08-01

    Full Text Available Background: Pulseoximetry is widely used in the critical care setting, currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SPO2 (puls-eoximetry oxygen saturation in intensive care unit after cardiac surgery. Our objective was to compare pulseoximetry with arterial oxygen saturation (SaO2 during clinical routine in such patients, and to examine the effect of mild acidosis on this relationship.Methods: In an observational prospective study 80 patients were evaluated in intensive care unit after cardiac surgery. SPO2 was recorded and compared with SaO2 obtained by blood gas analysis. One or serial arterial blood gas analyses (ABGs were performed via a radial artery line while a reliable pulseoximeter signal was present. One hundred thirty seven samples were collected and for each blood gas analyses, SaO2 and SPO2 we recorded.Results: O2 saturation as a marker of peripheral perfusion was measured by Pulseoxim-etry (SPO2. The mean difference between arterial oxygen saturation and pulseoximetry oxygen saturation was 0.12%±1.6%. A total of 137 paired readings demonstrated good correlation (r=0.754; P<0.0001 between changes in SPO2 and those in SaO2 in samples with normal hemoglobin. Also in forty seven samples with mild acidosis, paired readings demonstrated good correlation (r=0.799; P<0.0001 and the mean difference between SaO2 and SPO2 was 0.05%±1.5%.Conclusion: Data showed that in patients with stable hemodynamic and good signal quality, changes in pulseoximetry oxygen saturation reliably predict equivalent changes in arterial oxygen saturation. Mild acidosis doesn’t alter the relation between SPO2 and SaO2 to any clinically important extent. In conclusion, the pulse oximeter is useful to monitor oxygen saturation in patients with stable hemodynamic.

  1. Comparison of oxygen saturation values obtained from fingers on physically restrained or unrestrained sides of the body.

    Science.gov (United States)

    Korhan, Esra Akin; Yönt, Gülendam Hakverdioğlu; Khorshid, Leyla

    2011-01-01

    The aim of this study was to compare semiexperimentally the pulse oximetry values obtained from a finger on restrained or unrestrained sides of the body. The pulse oximeter provides a noninvasive measurement of the oxygen saturation of hemoglobin in arterial blood. One of the procedures most frequently applied to patients in intensive care units is the application of physical restraint. Circulation problems are the most important complication in patients who are physically restrained. Evaluation of oxygen saturation from body parts in which circulation is impeded or has deteriorated can cause false results. The research sample consisted of 30 hospitalized patients who participated in the study voluntarily and who were concordant with the inclusion criteria of the study. Patient information and patient follow-up forms were used for data collection. Pulse oximetry values were measured simultaneously using OxiMax Nellcor finger sensors from fingers on the restrained and unrestrained sides of the body. Numeric and percentile distributions were used in evaluating the sociodemographic properties of patients. A significant difference was found between the oxygen saturation values obtained from a finger of an arm that had been physically restrained and a finger of an arm that had not been physically restrained. The mean oxygen saturation value measured from a finger of an arm that had been physically restrained was found to be 93.40 (SD, 2.97), and the mean oxygen saturation value measured from a finger of an arm that had not been physically restrained was found to be 95.53 (SD, 2.38). The results of this study indicate that nurses should use a finger of an arm that is not physically restrained when evaluating oxygen saturation values to evaluate them correctly.

  2. Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry.

    Directory of Open Access Journals (Sweden)

    Laura M Langan

    Full Text Available Advanced in vitro culture from tissues of different origin includes three-dimensional (3D organoid micro structures that may mimic conditions in vivo. One example of simple 3D culture is spheroids; ball shaped structures typically used as liver and tumour models. Oxygen is critically important in physiological processes, but is difficult to quantify in 3D culture: and the question arises, how small does a spheroid have to be to have minimal micro-environment formation? This question is of particular importance in the growing field of 3D based models for toxicological assessment. Here, we describe a simple non-invasive approach modified for the quantitative measurement and subsequent evaluation of oxygen gradients in spheroids developed from a non-malignant fish cell line (i.e. RTG-2 cells using Electron Paramagnetic Resonance (EPR oximetry. Sonication of the paramagnetic probe Lithium phthalocyanine (LiPc allows for incorporation of probe particulates into spheroid during its formation. Spectra signal strength after incorporation of probe into spheroid indicated that a volume of 20 μl of probe (stock solution: 0.10 mg/mL is sufficient to provide a strong spectra across a range of spheroid sizes. The addition of non-toxic probes (that do not produce or consume oxygen report on oxygen diffusion throughout the spheroid as a function of size. We provide evidence supporting the use of this model over a range of initial cell seeding densities and spheroid sizes with the production of oxygen distribution as a function of these parameters. In our spheroid model, lower cell seeding densities (∼2,500 cells/spheroid and absolute size (118±32 μm allow control of factors such as pre-existing stresses (e.g. ∼ 2% normoxic/hypoxic interface for more accurate measurement of treatment response. The applied methodology provides an elegant, widely applicable approach to directly characterize spheroid (and other organoid cultures in biomedical and

  3. Pulse oximetry: fundamentals and technology update

    Directory of Open Access Journals (Sweden)

    Nitzan M

    2014-07-01

    Full Text Available Meir Nitzan,1 Ayal Romem,2 Robert Koppel31Department of Physics/Electro-Optics, Jerusalem College of Technology, Jerusalem, Israel; 2Pulmonary Institute, Shaare Zedek Medical Center, Jerusalem, Israel; 3Neonatal/Perinatal Medicine, Cohen Children's Medical Center of New York/North Shore-LIJ Health System, New Hyde Park, NY, United StatesAbstract: Oxygen saturation in the arterial blood (SaO2 provides information on the adequacy of respiratory function. SaO2 can be assessed noninvasively by pulse oximetry, which is based on photoplethysmographic pulses in two wavelengths, generally in the red and infrared regions. The calibration of the measured photoplethysmographic signals is performed empirically for each type of commercial pulse-oximeter sensor, utilizing in vitro measurement of SaO2 in extracted arterial blood by means of co-oximetry. Due to the discrepancy between the measurement of SaO2 by pulse oximetry and the invasive technique, the former is denoted as SpO2. Manufacturers of pulse oximeters generally claim an accuracy of 2%, evaluated by the standard deviation (SD of the differences between SpO2 and SaO2, measured simultaneously in healthy subjects. However, an SD of 2% reflects an expected error of 4% (two SDs or more in 5% of the examinations, which is in accordance with an error of 3%–4%, reported in clinical studies. This level of accuracy is sufficient for the detection of a significant decline in respiratory function in patients, and pulse oximetry has been accepted as a reliable technique for that purpose. The accuracy of SpO2 measurement is insufficient in several situations, such as critically ill patients receiving supplemental oxygen, and can be hazardous if it leads to elevated values of oxygen partial pressure in blood. In particular, preterm newborns are vulnerable to retinopathy of prematurity induced by high oxygen concentration in the blood. The low accuracy of SpO2 measurement in critically ill patients and newborns

  4. Retinal hemodynamic oxygen reactivity assessed by perfusion velocity, blood oximetry and vessel diameter measurements

    DEFF Research Database (Denmark)

    Klefter, Oliver Niels; Lauritsen, Anne Øberg; Larsen, Michael

    2015-01-01

    PURPOSE: To test the oxygen reactivity of a fundus photographic method of measuring macular perfusion velocity and to integrate macular perfusion velocities with measurements of retinal vessel diameters and blood oxygen saturation. METHODS: Sixteen eyes in 16 healthy volunteers were studied at two...... is a valid method for assessing macular perfusion. Results were consistent with previous observations of hyperoxic blood flow reduction using blue field entoptic and laser Doppler velocimetry. Retinal perfusion seemed to be regulated around individual set points according to blood glucose levels. Multimodal...

  5. False positive rate of carbon monoxide saturation by pulse oximetry of emergency department patients.

    Science.gov (United States)

    Weaver, Lindell K; Churchill, Susan K; Deru, Kayla; Cooney, Darryl

    2013-02-01

    Symptoms of carbon monoxide (CO) poisoning are non-specific. Diagnosis requires suspicion of exposure, confirmed by measuring ambient CO levels or carboxyhemoglobin (COHb). An FDA-approved pulse oximeter (Rad-57) can measure CO saturation (S(pCO)). The device accuracy has implications for clinical decision-making. From April 1 to August 15, 2008, study personnel measured S(pCO) and documented demographic factors at time of clinical blood draw, in a convenience sample of 1,363 subjects presenting to the emergency department at Intermountain Medical Center, Murray, Utah. The technician then assayed COHb. COHb and S(pCO) values were compared by subject; false positive or negative values were defined as S(pCO) at least 3 percentage points greater or less than COHb level, reported by the manufacturer to be ± 1 SD in performance. In 1,363 subjects, 613 (45%) were male, 1,141 (84%) were light-skinned, 14 in shock, 4 with CO poisoning, and 122 (9%) met the criteria for a false positive value (range 3-19 percentage points), while 247 (18%) met the criteria for a false negative value (-13 to -3 percentage points). Risks for a false positive S(pCO) reading included being female and having a lower perfusion index. Methemoglobin, body temperature, and blood pressure also appear to influence the S(pCO) accuracy. There was variability among monitors, possibly related to technician technique, as rotation of monitors among technicians was not enforced. While the Rad-57 pulse oximeter functioned within the manufacturer's specifications, clinicians using the Rad-57 should expect some S(pCO) readings to be significantly higher or lower than COHb measurements, and should not use S(pCO) to direct triage or patient management. An elevated S(pCO) could broaden the diagnosis of CO poisoning in patients with non-specific symptoms. However, a negative S(pCO) level in patients suspected of having CO poisoning should never rule out CO poisoning, and should always be confirmed by COHb. © 2013

  6. The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit.

    Science.gov (United States)

    Prasetyono, Theddeus O H; Adianto, Senja

    2013-09-01

    The aim of this study was to collect important data on the time of oxygen saturation change in relation to skin flap color alteration using non-invasive pulse oximetry to evaluate its ability to provide continuous monitoring of skin flap perfusion. An experimental study on the monitoring of blood perfusion of 20 tube-island groin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animals were randomly assigned to one of two groups representing a blockage of either arterial or venous blood flow. The oxygen saturation change and clinical color alteration were monitored from the beginning of vessel clamping until the saturation became undetectable. The result was analyzed by the t-test using SSPS ver. 10.0. The mean times from the vessel clamping until the saturation became undetectable were 20.19±2.13 seconds and 74.91±10.57 seconds for the artery and vein clamping groups, respectively. The mean time of the clinical alteration from the beginning of vein clamping was 34.5±11.72 minutes, while the alteration in flaps with artery clamping could not be detected until 2.5 hours after clamping. The use of neonate-type reusable flex sensor-pulse oximetry is objective and effective in early detection of arterial and vein blockage. It provides real-time data on vessel occlusion, which in turn will allow for early salvaging. The detection periods of both arterial occlusion and venous congestion are much earlier than the color alteration one may encounter clinically.

  7. The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit

    Directory of Open Access Journals (Sweden)

    Theddeus O. H. Prasetyono

    2013-09-01

    Full Text Available BackgroundThe aim of this study was to collect important data on the time of oxygen saturation change in relation to skin flap color alteration using non-invasive pulse oximetry to evaluate its ability to provide continuous monitoring of skin flap perfusion.MethodsAn experimental study on the monitoring of blood perfusion of 20 tube-island groin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animals were randomly assigned to one of two groups representing a blockage of either arterial or venous blood flow. The oxygen saturation change and clinical color alteration were monitored from the beginning of vessel clamping until the saturation became undetectable. The result was analyzed by the t-test using SSPS ver. 10.0.ResultsThe mean times from the vessel clamping until the saturation became undetectable were 20.19±2.13 seconds and 74.91±10.57 seconds for the artery and vein clamping groups, respectively. The mean time of the clinical alteration from the beginning of vein clamping was 34.5±11.72 minutes, while the alteration in flaps with artery clamping could not be detected until 2.5 hours after clamping.ConclusionsThe use of neonate-type reusable flex sensor-pulse oximetry is objective and effective in early detection of arterial and vein blockage. It provides real-time data on vessel occlusion, which in turn will allow for early salvaging. The detection periods of both arterial occlusion and venous congestion are much earlier than the color alteration one may encounter clinically.

  8. Brain oxygen saturation assessment in neonates using T2-prepared blood imaging of oxygen saturation and near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Alderliesten, Thomas; De Vis, Jill B; Lemmers, Petra Ma

    2017-01-01

    saturation in the sagittal sinus (R(2 )= 0.49, p = 0.023), but no significant correlations could be demonstrated with frontal and whole brain cerebral blood flow. These results suggest that measuring oxygen saturation by T2-prepared blood imaging of oxygen saturation is feasible, even in neonates. Strong...... sinus. A strong linear relation was found between the oxygen saturation measured by magnetic resonance imaging and the oxygen saturation measured by near-infrared spectroscopy (R(2 )= 0.64, p ..., and magnetic resonance imaging measures of frontal cerebral blood flow, whole brain cerebral blood flow and venous oxygen saturation in the sagittal sinus (R(2 )= 0.71, 0.50, 0.65; p 

  9. Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers

    International Nuclear Information System (INIS)

    Shafique, M; Kyriacou, P A

    2012-01-01

    Pulse oximetry utilizes the technique of photoplethysmography to estimate arterial oxygen saturation (SpO 2 ) values. During hypothermia, the amplitude of the photoplethysmograph (PPG) is compromised which can lead to inaccurate estimation of SpO 2 . A new mutlimode PPG/pulse oximeter sensor was developed to investigate the behaviour of PPGs during conditions of induced hypothermia (hand immersed in an ice bath). PPG measurements from 20 volunteers were conducted and SpO 2 values were estimated at all stages of the experiment. Good quality PPG signals were observed from the majority of the volunteers at almost all hand temperatures. At low temperature ranges, from 13 to 21 °C, the failure rate to estimate SpO 2 values from the multimode transreflectance PPG sensor was 2.4% as compared to the commercial pulse oximeter with a failure rate of 70%. (paper)

  10. The relationship between cerebral oxygen saturation changes and post operative neurologic complications in patients undergoing cardiac surgery

    International Nuclear Information System (INIS)

    Negargar, S.; Mahmoudpour, A.; Taheri, R.; Sarvin, S.

    2007-01-01

    To study the relationship between cerebral oxygen saturation changes and postoperative neurologic complications. Seventy two adult patients with ASA class II, III who were scheduled for elective cardiac surgery, were randomized into three groups: Group I: with CPB (on -pump) Group II: without CPB (off- pump) Group III: valve surgery. Neuropsychological outcome was assessed by the Mini-Mental State Examination (MMSE). Cerebral oxygen saturation was also measured. There was no statistical difference in desaturation of more than 20% among three groups (P=0.113) but it was significant between group I and II (P=0.042). Changes of rSo/sub 2/ in different hours of surgery was significant in group I and group II (P=0.0001 in both) but it was not significant in group III ( P=0.075) . Although cerebral oximetry is a noninvasive and useful method of monitoring during cardiac surgery, it has low accuracy to determine postoperative neurologic complications. (author)

  11. Pulse oximetry in bronchiolitis: is it needed?

    Directory of Open Access Journals (Sweden)

    Hendaus MA

    2015-10-01

    Full Text Available Mohamed A Hendaus,1,2 Fatima A Jomha,3 Ahmed H Alhammadi,1,2 1Department of Pediatrics, General Pediatrics Division, Hamad Medical Corporation, 2Weill-Cornell Medical College, Doha, Qatar; 3School of Pharmacy, Lebanese International University, Khiara, Lebanon Abstract: Infants admitted to health-care centers with acute bronchiolitis are frequently monitored with a pulse oximeter, a noninvasive method commonly used for measuring oxygen saturation. The decision to hospitalize children with bronchiolitis has been largely influenced by pulse oximetry, despite its questionable diagnostic value in delineating the severity of the illness. Many health-care providers lack the appropriate clinical fundamentals and limitations of pulse oximetry. This deficiency in knowledge might have been linked to changes in the management of bronchiolitis. The aim of this paper is to provide the current evidence on the role of pulse oximetry in bronchiolitis. We discuss the history, fundamentals of operation, and limitations of the apparatus. A search of the Google Scholar, Embase, Medline, and PubMed databases was carried out for published articles covering the use of pulse oximetry in bronchiolitis. Keywords: bronchiolitis, children, monitor, oxygen

  12. Retinal oxygen saturation before and after glaucoma surgery.

    Science.gov (United States)

    Nitta, Eri; Hirooka, Kazuyuki; Shimazaki, Takeru; Sato, Shino; Ukegawa, Kaori; Nakano, Yuki; Tsujikawa, Akitaka

    2017-08-01

    This study compared retinal vessel oxygen saturation before and after glaucoma surgery. Retinal oxygen saturation in glaucoma patients was measured using a non-invasive spectrophotometric retinal oximeter. Adequate image quality was found in 49 of the 108 consecutive glaucoma patients recruited, with 30 undergoing trabeculectomy, 11 EX-PRESS and eight trabeculotomy. Retinal oxygen saturation measurements in the retinal arterioles and venules were performed at 1 day prior to and at approximately 10 days after surgery. Statistical analysis was performed using a Student's t-test. After glaucoma surgery, intraocular pressure (IOP) decreased from 19.8 ± 7.7 mmHg to 9.0 ± 5.7 mmHg (p glaucoma surgery had an effect on the retinal venous oxygen saturation. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Renal vein oxygen saturation in renal artery stenosis

    DEFF Research Database (Denmark)

    Nielsen, K; Rehling, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Renal vein oxygen-saturation was measured in 56 patients with arterial hypertension and unilateral stenosis or occlusion of the renal artery. Oxygen-saturation in blood from the ischaemic kidney (84.4%, range 73-93%) was significantly higher than that from the 'normal' contralateral kidney (81...... than its blood flow. This is probably due to decreased filtration fraction and filtered sodium with subsequent reduction in absolute tubular re-absorption of sodium ions....

  14. Rapid determination of oxygen saturation and vascularity for cancer detection.

    Directory of Open Access Journals (Sweden)

    Fangyao Hu

    Full Text Available A rapid heuristic ratiometric analysis for estimating tissue hemoglobin concentration and oxygen saturation from measured tissue diffuse reflectance spectra is presented. The analysis was validated in tissue-mimicking phantoms and applied to clinical measurements in head and neck, cervical and breast tissues. The analysis works in two steps. First, a linear equation that translates the ratio of the diffuse reflectance at 584 nm and 545 nm to estimate the tissue hemoglobin concentration using a Monte Carlo-based lookup table was developed. This equation is independent of tissue scattering and oxygen saturation. Second, the oxygen saturation was estimated using non-linear logistic equations that translate the ratio of the diffuse reflectance spectra at 539 nm to 545 nm into the tissue oxygen saturation. Correlations coefficients of 0.89 (0.86, 0.77 (0.71 and 0.69 (0.43 were obtained for the tissue hemoglobin concentration (oxygen saturation values extracted using the full spectral Monte Carlo and the ratiometric analysis, for clinical measurements in head and neck, breast and cervical tissues, respectively. The ratiometric analysis was more than 4000 times faster than the inverse Monte Carlo analysis for estimating tissue hemoglobin concentration and oxygen saturation in simulated phantom experiments. In addition, the discriminatory power of the two analyses was similar. These results show the potential of such empirical tools to rapidly estimate tissue hemoglobin in real-time spectral imaging applications.

  15. Diffuse reflectance spectroscopy for the measurement of tissue oxygen saturation

    International Nuclear Information System (INIS)

    Sircan-Kucuksayan, A; Canpolat, M; Uyuklu, M

    2015-01-01

    Tissue oxygen saturation (StO 2 ) is a useful parameter for medical applications. A spectroscopic method has been developed to detect pathologic tissues, due to a lack of normal blood circulation, by measuring StO 2 . In this study, human blood samples with different levels of oxygen saturation have been prepared and spectra were acquired using an optical fiber probe to investigate the correlation between the oxygen saturation levels and the spectra. A linear correlation between the oxygen saturation and ratio of the intensities (760 nm to 790 nm) of the spectra acquired from blood samples has been found. In a validation study, oxygen saturations of the blood samples were estimated from the spectroscopic measurements with an error of 2.9%. It has also been shown that the linear dependence between the ratio and the oxygen saturation of the blood samples was valid for the blood samples with different hematocrits. Spectra were acquired from the forearms of 30 healthy volunteers to estimate StO 2 prior to, at the beginning of, after 2 min, and at the release of total vascular occlusion. The average StO 2 of a forearm before and after the two minutes occlusion was significantly different. The results suggested that optical reflectance spectroscopy is a sensitive method to estimate the StO 2 levels of human tissue. The technique developed to measure StO 2 has potential to detect ischemia in real time. (paper)

  16. Evaluation of Nd:YAG laser on partial oxygen saturation of pulpal blood in anterior hypersensitive teeth.

    Science.gov (United States)

    Birang, Reza; Kaviani, Naser; Mohammadpour, Mehdi; Abed, Ahmad Moghareh; Gutknecht, Norbert; Mir, Maziar

    2008-07-01

    Dentine hypersensitivity has of long been known to be a common clinical problem in dental practices. Lasers have recently come to play a prominent role in the treatment of this disorder. They might, however, cause dental pulp damage. This study was conducted to evaluate the effect of Nd:yttrium-aluminum-garnet (YAG) laser on partial oxygen saturation of pulpal blood in sensitive anterior teeth. In this clinical trial, 65 hypersensitive teeth were selected and randomly allocated to two groups. The study group involved Nd:YAG laser treatment, while no treatment was employed for the control group. Using a pulse oximetry system, evaluations were preformed of the partial oxygen saturation in the pulpal blood before, immediately after, 1 week after, and 1 month after the treatment. The results were analyzed using the SPSS software and repeated-measures analysis of variance and paired-samples t tests. The mean partial oxygen saturation of the blood was found to be 85.4% in the study group, which was not significantly different from that of the control group. No significant differences were observed in the control group between the means obtained from pretreatment and post-treatment intervals (P > 0.05). The Post-treatment partial oxygen saturation mean rose to 89.3% (P = 0.001) and remained constant throughout the following week after it. However, no significant differences were found between the pretreatment partial oxygen saturation mean and the same measurement 1 month after treatment (P = 0.702). Nd:YAG laser therapy for dentine desensitization of anterior teeth caused no persistent changes in the partial oxygen saturation of pulpal blood. It may, therefore, be concluded that the diffusion of heat induced by the Nd:YAG laser into the pulp within the limit of the desensitization parameters cause no irreversible damages in the dental pulp.

  17. COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE

    Directory of Open Access Journals (Sweden)

    Muhaji

    2017-12-01

    Full Text Available Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU, which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube. Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube. Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis. Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05. The mean difference of oxygen saturation between both groups was 13.157. Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT.

  18. Investigating tissue respiration and skin microhaemocirculation under adaptive changes and the synchronization of blood flow and oxygen saturation rhythms

    International Nuclear Information System (INIS)

    Dunaev, A V; Palmer, S G; Stewart, N A; Sokolovski, S G; Rafailov, E U; Sidorov, V V; Krupatkin, A I; Rafailov, I E

    2014-01-01

    Multi-functional laser non-invasive diagnostic systems allow the study of a number of microcirculatory parameters, including index of blood microcirculation (I m ) (by laser Doppler flowmetry, LDF) and oxygen saturation (S t O 2 ) of skin tissue (by tissue reflectance oximetry, TRO). This research aimed to use such a system to investigate the synchronization of microvascular blood flow and oxygen saturation rhythms under normal and adaptive change conditions. Studies were conducted on eight healthy volunteers of 21–49 years. These volunteers were observed between one and six months, totalling 422 basic tests (3 min each). Measurements were performed on the palmar surface of the right middle finger and the lower forearm's medial surface. Rhythmic oscillations of LDF and TRO were studied using wavelet analysis. Combined tissue oxygen consumption data for all volunteers during ‘adaptive changes’ increased relative to normal conditions with and without arteriovenous anastomoses. Data analysis revealed resonance and synchronized rhythms in microvascular blood flow and oxygen saturation as an adaptive change in myogenic oscillation (vasomotion) resulting from exercise and possibly psychoemotional stress. Synchronization of myogenic rhythms during adaptive changes may lead to increased oxygen consumption as a result of increased microvascular blood flow velocity. (paper)

  19. Lung vital capacity and oxygen saturation in adults with cerebral palsy

    Directory of Open Access Journals (Sweden)

    Lampe R

    2014-12-01

    saturation, and between chest expansion and oxygen saturation was found. The scoliotic deformities of the spine were associated with an additional decrease in the vital capacity, but this did not affect blood oxygen supply. Conclusion: Despite the decreased chest expansion and the significantly reduced lung volume in adults with cerebral palsy, sufficient oxygen supply was registered. Keywords: disability, lung function, spirometry, chest expansion, pulse oximetry

  20. Central venous oxygen saturation during hypovolaemic shock in humans

    DEFF Research Database (Denmark)

    Madsen, P; Iversen, H; Secher, N H

    1993-01-01

    We compared central venous oxygen saturation and central venous pressure (CVP) as indices of the effective blood volume during 50 degrees head-up tilt (anti-Trendelenburg's position) induced hypovolaemic shock in eight healthy subjects. Head-up tilt increased thoracic electrical impedance from 31...... (28-36) (median and range) to 34 (30-40) Ohm, mean arterial pressure (MAP) from 79 (70-88) to 86 (80-99) mmHg, heart rate (HR) from 67 (56-71) to 99 (78-119) beats min-1 (p ....05) but thereafter remained stable. In contrast, central venous oxygen saturation showed a linear decrease with time from 0.75 (0.69-0.78) at rest to 0.60 (0.49-0.67) (p measurement of central venous oxygen saturation...

  1. Changes in retinal venular oxygen saturation predict activity of proliferative diabetic retinopathy 3 months after panretinal photocoagulation.

    Science.gov (United States)

    Torp, Thomas Lee; Kawasaki, Ryo; Wong, Tien Yin; Peto, Tunde; Grauslund, Jakob

    2018-03-01

    Proliferative diabetic retinopathy (PDR) is a severe blinding condition. We investigated whether retinal metabolism, measured by retinal oximetry, may predict PDR activity after panretinal laser photocoagulation (PRP). We performed a prospective, interventional, clinical study of patients with treatment-naive PDR. Wide-field fluorescein angiography (OPTOS, Optomap) and global and focal retinal oximetry (Oxymap T1) were performed at baseline (BL), and 3 months (3M) after PRP. Angiographic findings were used to divide patients according to progression or non-progression of PDR after PRP. We evaluated differences in global and focal retinal oxygen saturation between patients with and without progression of PDR after PRP treatment. We included 45 eyes of 37 patients (median age and duration of diabetes were 51.6 and 20 years). Eyes with progression of PDR developed a higher retinal venous oxygen saturation than eyes with non-progression at 3M (global: +5.9% (95% CI -1.5 to 12.9), focal: +5.4%, (95% CI -4.1 to 14.8)). Likewise, progression of PDR was associated with a lower arteriovenular (AV) oxygen difference between BL and 3M (global: -6.1%, (95% CI -13.4 to -1.4), focal: -4.5% (95% CI -12.1 to 3.2)). In a multiple logistic regression model, increment in global retinal venular oxygen saturation (OR 1.30 per 1%-point increment, p=0.017) and decrement in AV oxygen saturation difference (OR 0.72 per 1%-point increment, p=0.016) at 3M independently predicted progression of PDR. Development of higher retinal venular and lower AV global oxygen saturation independently predicts progression of PDR despite standard PRP and might be a potential non-invasive marker of angiogenic disease activity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Poincaré analysis of an overnight arterial oxygen saturation signal applied to the diagnosis of sleep apnea hypopnea syndrome

    International Nuclear Information System (INIS)

    Morillo, Daniel S; Rojas, Juan L; Crespo, Luis F; León, Antonio; Gross, Nicole

    2009-01-01

    The analysis of oxygen desaturations is a basic variable in polysomnographic studies for the diagnosis of sleep apnea. Several algorithms operating in the time domain already exist for sleep apnea detection via pulse oximetry, but in a disadvantageous way—they achieve either a high sensitivity or a high specificity. The aim of this study was to assess whether an alternative analysis of arterial oxygen saturation (SaO 2 ) signals from overnight pulse oximetry could yield essential information on the diagnosis of sleep apnea hypopnea syndrome (SAHS). SaO 2 signals from 117 subjects were analyzed. The population was divided into a learning dataset (70 patients) and a test set (47 patients). The learning set was used for tuning thresholds among the applied Poincaré quantitative descriptors. Results showed that the presence of apnea events in SAHS patients caused an increase in the SD 1 Poincaré parameter. This conclusion was assessed prospectively using the test dataset. 90.9% sensitivity and 84.0% specificity were obtained in the test group. We conclude that Poincaré analysis could be useful in the study of SAHS, contributing to reduce the demand for polysomnographic studies in SAHS screening

  3. In vivo evidence of methamphetamine induced attenuation of brain tissue oxygenation as measured by EPR oximetry

    International Nuclear Information System (INIS)

    Weaver, John; Yang, Yirong; Purvis, Rebecca; Weatherwax, Theodore; Rosen, Gerald M.; Liu, Ke Jian

    2014-01-01

    Abuse of methamphetamine (METH) is a major and significant societal problem in the US, as a number of studies have suggested that METH is associated with increased cerebrovascular events, hemorrhage or vasospasm. Although cellular and molecular mechanisms involved in METH-induced toxicity are not completely understood, changes in brain O 2 may play an important role and contribute to METH-induced neurotoxicity including dopaminergic receptor degradation. Given that O 2 is the terminal electron acceptor for many enzymes that are important in brain function, the impact of METH on brain tissue pO 2 in vivo remains largely uncharacterized. This study investigated striatal tissue pO 2 changes in male C57BL/6 mice (16–20 g) following METH administration using EPR oximetry, a highly sensitive modality to measure pO 2 in vivo, in situ and in real time. We demonstrate that 20 min after a single injection of METH (8 mg/kg i.v.), the striatal pO 2 was reduced to 81% of the pretreatment level and exposure to METH for 3 consecutive days further attenuated striatal pO 2 to 64%. More importantly, pO 2 did not recover fully to control levels even 24 h after administration of a single dose of METH and continual exposure to METH exacerbates the condition. We also show a reduction in cerebral blood flow associated with a decreased brain pO 2 indicating an ischemic condition. Our findings suggests that administration of METH can attenuate brain tissue pO 2 , which may lead to hypoxic insult, thus a risk factor for METH-induced brain injury and the development of stroke in young adults. - Highlights: • Explored striatal tissue pO 2 in vivo after METH administration by EPR oximetry. • pO 2 was reduced by 81% after a single dose and 64% after 3 consecutive daily doses. • pO 2 did not recover fully to control levels even 24 h after a single dose. • Decrease in brain tissue pO 2 may be associated with a decrease in CBF. • Administration of methamphetamine may lead to hypoxic

  4. In vivo evidence of methamphetamine induced attenuation of brain tissue oxygenation as measured by EPR oximetry

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, John, E-mail: jmweaver@salud.unm.edu [Center of Biomedical Research Excellence, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Yang, Yirong [Center of Biomedical Research Excellence, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Purvis, Rebecca [Center of Biomedical Research Excellence, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Department of Neurology, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Weatherwax, Theodore [Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Rosen, Gerald M. [Center for Biomedical Engineering and Technology, University of Maryland, Baltimore, MD 21201 (United States); Center for EPR Imaging In Vivo Physiology, University of Maryland, Baltimore, MD 21201 (United States); Department of Pharmaceutical Sciences, University of Maryland School of Pharmacy, Baltimore, MD 21201 (United States); Liu, Ke Jian [Center of Biomedical Research Excellence, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Department of Neurology, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States)

    2014-03-01

    Abuse of methamphetamine (METH) is a major and significant societal problem in the US, as a number of studies have suggested that METH is associated with increased cerebrovascular events, hemorrhage or vasospasm. Although cellular and molecular mechanisms involved in METH-induced toxicity are not completely understood, changes in brain O{sub 2} may play an important role and contribute to METH-induced neurotoxicity including dopaminergic receptor degradation. Given that O{sub 2} is the terminal electron acceptor for many enzymes that are important in brain function, the impact of METH on brain tissue pO{sub 2}in vivo remains largely uncharacterized. This study investigated striatal tissue pO{sub 2} changes in male C57BL/6 mice (16–20 g) following METH administration using EPR oximetry, a highly sensitive modality to measure pO{sub 2}in vivo, in situ and in real time. We demonstrate that 20 min after a single injection of METH (8 mg/kg i.v.), the striatal pO{sub 2} was reduced to 81% of the pretreatment level and exposure to METH for 3 consecutive days further attenuated striatal pO{sub 2} to 64%. More importantly, pO{sub 2} did not recover fully to control levels even 24 h after administration of a single dose of METH and continual exposure to METH exacerbates the condition. We also show a reduction in cerebral blood flow associated with a decreased brain pO{sub 2} indicating an ischemic condition. Our findings suggests that administration of METH can attenuate brain tissue pO{sub 2}, which may lead to hypoxic insult, thus a risk factor for METH-induced brain injury and the development of stroke in young adults. - Highlights: • Explored striatal tissue pO{sub 2}in vivo after METH administration by EPR oximetry. • pO{sub 2} was reduced by 81% after a single dose and 64% after 3 consecutive daily doses. • pO{sub 2} did not recover fully to control levels even 24 h after a single dose. • Decrease in brain tissue pO{sub 2} may be associated with a decrease in

  5. Reliability of pulse oximetry during cardiopulmonary resuscitation in a piglet model of neonatal cardiac arrest.

    Science.gov (United States)

    Hassan, Mohammad Ahmad; Mendler, Marc; Maurer, Miriam; Waitz, Markus; Huang, Li; Hummler, Helmut D

    2015-01-01

    Pulse oximetry is widely used in intensive care and emergency conditions to monitor arterial oxygenation and to guide oxygen therapy. To study the reliability of pulse oximetry in comparison with CO-oximetry in newborn piglets during cardiopulmonary resuscitation (CPR). In a prospective cohort study in 30 healthy newborn piglets, cardiac arrest was induced, and thereafter each piglet received CPR for 20 min. Arterial oxygen saturation was monitored continuously by pulse oximetry (SpO2). Arterial blood was analyzed for functional oxygenation (SaO2) every 2 min. SpO2 was compared with coinciding SaO2 values and bias considered whenever the difference (SpO2 - SaO2) was beyond ±5%. Bias values were decreased at the baseline measurements (mean: 2.5 ± 4.6%) with higher precision and accuracy compared with values across the experiment. Two minutes after cardiac arrest, there was a marked decrease in precision and accuracy as well as an increase in bias up to 13 ± 34%, reaching a maximum of 45.6 ± 28.3% after 10 min over a mean SaO2 range of 29-58%. Pulse oximetry showed increased bias and decreased accuracy and precision during CPR in a model of neonatal cardiac arrest. We recommend further studies to clarify the exact mechanisms of these false readings to improve reliability of pulse oximetry during the marked desaturation and hypoperfusion found during CPR. © 2014 S. Karger AG, Basel.

  6. Effects of targeting lower versus higher arterial oxygen saturations on death or disability in preterm infants.

    Science.gov (United States)

    Askie, Lisa M; Darlow, Brian A; Davis, Peter G; Finer, Neil; Stenson, Ben; Vento, Maximo; Whyte, Robin

    2017-04-11

    The use of supplemental oxygen in the care of extremely preterm infants has been common practice since the 1940s. Despite this, there is little agreement regarding which oxygen saturation (SpO₂) ranges to target to maximise short- or long-term growth and development, while minimising harms. There are two opposing concerns. Lower oxygen levels (targeting SpO₂ at 90% or less) may impair neurodevelopment or result in death. Higher oxygen levels (targeting SpO₂ greater than 90%) may increase severe retinopathy of prematurity or chronic lung disease.The use of pulse oximetry to non-invasively assess neonatal SpO₂ levels has been widespread since the 1990s. Until recently there were no randomised controlled trials (RCTs) that had assessed whether it is better to target higher or lower oxygen saturation levels in extremely preterm infants, from birth or soon thereafter. As a result, there is significant international practice variation and uncertainty remains as to the most appropriate range to target oxygen saturation levels in preterm and low birth weight infants. 1. What are the effects of targeting lower versus higher oxygen saturation ranges on death or major neonatal and infant morbidities, or both, in extremely preterm infants?2. Do these effects differ in different types of infants, including those born at a very early gestational age, or in those who are outborn, without antenatal corticosteroid coverage, of male sex, small for gestational age or of multiple birth, or by mode of delivery? We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2016, Issue 4), MEDLINE via PubMed (1966 to 11 April 2016), Embase (1980 to 11 April 2016) and CINAHL (1982 to 11 April 2016). We also searched clinical trials databases, conference proceedings and the reference lists of retrieved articles for randomised controlled trials. Randomised controlled trials that enrolled babies born at less than 28

  7. In vivo evidence of methamphetamine induced attenuation of brain tissue oxygenation as measured by EPR oximetry

    Science.gov (United States)

    Weaver, John; Yang, Yirong; Purvis, Rebecca; Weatherwax, Theodore; Rosen, Gerald M.; Liu, Ke Jian

    2014-01-01

    Abuse of methamphetamine (METH) is a major and significant societal problem in the US, as a number of studies have suggested that METH is associated with increased cerebrovascular events, hemorrhage or vasospasm. Although cellular and molecular mechanisms involved in METH-induced toxicity are not completely understood, changes in brain O2 may play an important role and contribute to METH-induced neurotoxicity including dopaminergic receptor degradation. Given that O2 is the terminal electron acceptor for many enzymes that are important in brain function, the impact of METH on brain tissue pO2 in vivo remains largely uncharacterized. This study investigated striatal tissue pO2 changes in male C57BL/6 mice (16–20g) following METH administration using EPR oximetry, a highly sensitive modality to measure pO2 in vivo, in situ and in real time. We demonstrate that 20 min after a single injection of METH (8 mg/kg i.v.), the striatal pO2 was reduced to 81% of the pretreatment level and exposure to METH for 3 consecutive days further attenuated striatal pO2 to 64%. More importantly, pO2 did not recover fully to control levels even 24 hrs after administration of a single dose of METH. and continual exposure to METH exacerbates the condition. We also show a reduction in cerebral blood flow associated with a decreased brain pO2 indicating an ischemic condition. Our findings suggests that administration of METH can attenuate brain tissue pO2, which may lead to hypoxic insult, thus a risk factor for METH-induced brain injury and the development of stroke in young adults. PMID:24412707

  8. In vivo detection of hemoglobin oxygen saturation and carboxyhemoglobin saturation with multiwavelength photoacoustic microscopy.

    Science.gov (United States)

    Chen, Zhongjiang; Yang, Sihua; Xing, Da

    2012-08-15

    A method for noninvasively detecting hemoglobin oxygen saturation (SO2) and carboxyhemoglobin saturation (SCO) in subcutaneous microvasculature with multiwavelength photoacoustic microscopy is presented. Blood samples mixed with different concentrations of carboxyhemoglobin were used to test the feasibility and accuracy of photoacoustic microscopy compared with the blood-gas analyzer. Moreover, fixed-point detection of SO2 and SCO in mouse ear was obtained, and the changes from normoxia to carbon monoxide hypoxia were dynamically monitored in vivo. Experimental results demonstrate that multiwavelength photoacoustic microscopy can detect SO2 and SCO, which has future potential clinical applications.

  9. Advanced Pulse Oximetry System for Remote Monitoring and Management

    Science.gov (United States)

    Pak, Ju Geon; Park, Kee Hyun

    2012-01-01

    Pulse oximetry data such as saturation of peripheral oxygen (SpO2) and pulse rate are vital signals for early diagnosis of heart disease. Therefore, various pulse oximeters have been developed continuously. However, some of the existing pulse oximeters are not equipped with communication capabilities, and consequently, the continuous monitoring of patient health is restricted. Moreover, even though certain oximeters have been built as network models, they focus on exchanging only pulse oximetry data, and they do not provide sufficient device management functions. In this paper, we propose an advanced pulse oximetry system for remote monitoring and management. The system consists of a networked pulse oximeter and a personal monitoring server. The proposed pulse oximeter measures a patient's pulse oximetry data and transmits the data to the personal monitoring server. The personal monitoring server then analyzes the received data and displays the results to the patient. Furthermore, for device management purposes, operational errors that occur in the pulse oximeter are reported to the personal monitoring server, and the system configurations of the pulse oximeter, such as thresholds and measurement targets, are modified by the server. We verify that the proposed pulse oximetry system operates efficiently and that it is appropriate for monitoring and managing a pulse oximeter in real time. PMID:22933841

  10. REFLECTANCE PULSE OXIMETRY AT THE FOREHEAD IMPROVES BY PRESSURE ON THE PROBE

    NARCIS (Netherlands)

    DASSEL, ACM; GRAAFF, R; SIKKEMA, M; ZIJLSTRA, WG; AARNOUDSE, JG

    In this study, we investigated the possibility of improving reflectance (back-scatter) pulse oximetry measurements by pressure applied to the probe. Optimal signal detection, with the probe applied to an easily accessible location, is important to prevent erroneous oxygen saturation readouts. At the

  11. The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit

    Directory of Open Access Journals (Sweden)

    Theddeus O. H. Prasetyono

    2013-09-01

    Full Text Available Background The aim of this study was to collect important data on the time of oxygensaturation change in relation to skin flap color alteration using non-invasive pulse oximetryto evaluate its ability to provide continuous monitoring of skin flap perfusion.Methods An experimental study on the monitoring of blood perfusion of 20 tube-islandgroin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animalswere randomly assigned to one of two groups representing a blockage of either arterial orvenous blood flow. The oxygen saturation change and clinical color alteration were monitoredfrom the beginning of vessel clamping until the saturation became undetectable. The resultwas analyzed by the t-test using SSPS ver. 10.0.Results The mean times from the vessel clamping until the saturation became undetectablewere 20.19±2.13 seconds and 74.91±10.57 seconds for the artery and vein clamping groups,respectively. The mean time of the clinical alteration from the beginning of vein clampingwas 34.5±11.72 minutes, while the alteration in flaps with artery clamping could not bedetected until 2.5 hours after clamping.Conclusions The use of neonate-type reusable flex sensor-pulse oximetry is objective andeffective in early detection of arterial and vein blockage. It provides real-time data on vesselocclusion, which in turn will allow for early salvaging. The detection periods of both arterialocclusion and venous congestion are much earlier than the color alteration one may encounterclinically.

  12. In-vivo continuous monitoring of mixed venous oxygen saturation by photoacoustic transesophageal echocardiography (Conference Presentation)

    Science.gov (United States)

    Li, Li; Subramaniam, Balachundhar; Aguirre, Aaron D.; Andrawes, Michael N.; Tearney, Guillermo J.

    2016-02-01

    Mixed venous oxygen saturation (SvO2), measured from pulmonary arteries, is a gold-standard measure of the dynamic balance between the oxygen supply and demand in the body. In critical care, continuous monitoring of SvO2 plays a vital role in early detection of circulatory shock and guiding goal-oriented resuscitation. In current clinical practice, SvO2 is measured by invasive pulmonary artery catheters (PAC), which are associated with a 10% risk of severe complications. To address the unmet clinical need for a non-invasive SvO2 monitor, we are developing a new technology termed photoacoustic transesophageal echocardiography (PA-TEE). PA-TEE integrates transesophageal echocardiography with photoacoustic oximetry, and enables continuous assessment of SvO2 through an esophageal probe that can be inserted into the body in a minimally invasive manner. We have constructed a clinically translatable PA-TEE prototype, which features a mobile OPO laser, a modified ultrasonography console and a dual-modality esophageal probe. Comprised of a rotatable acoustic array detector, a flexible optical fiber bundle and a light-integrating acoustic lens, the oximetric probe has an outer diameter smaller than 15 mm and will be tolerable for most patients. Through custom-made C++/Qt software, our device acquires and displays ultrasonic and photoacoustic images in real time to guide the deployment of the probe. SvO2 is calculated on-line and updated every second. PA-TEE has now been used to evaluate SvO2 in living swine. Our findings show that changing the fraction of oxygen in the inspired gas modulates SvO2 measured by PA-TEE. Statistic comparison between SvO2 measurements from PA-TEE in vivo the gold-standard laboratorial analysis on blood samples drawn from PACs will be presented.

  13. Prediction of saturation using the carbon/oxygen log

    Energy Technology Data Exchange (ETDEWEB)

    Horner, S.C.; Sanyal, S.K.

    1984-09-01

    This project investigates the nature of Dresser-Atlas Carbon/Oxygen Log gamma ray spectra. It presents an attempt to improve the signal-to-noise ratio of the C/O and Si/Ca parameters used by Dresser-Atlas to determine oil saturation. Two techniques were developed to subtract the Compton background from the spectral data. Neither technique significantly improves the accuracy of the cased-hole prediction of oil saturation. However, it has been shown that it is possible to develop a satisfactory correlation for oil saturation on a well-by-well basis. This correlation can then be used to generate oil-in-place from the C/O and Si/Ca ratios. 17 references.

  14. [Association between oxygen saturation and cognitive function in older adults from longevity areas in China].

    Science.gov (United States)

    Su, L Q; Yin, Z X; Xu, N; Lyu, Y B; Luo, J S; Shi, X M

    2016-07-06

    To explore the relationship between oxygen saturation (SpO2) and cognitive function in older adults from longevity areas in China. A total of 2 285 participants aged ≥65 years according to the 2012 Chinese Longitudinal Healthy Longevity Survey were included in this study. Among them, 1 739 participants aged 65-99 years were randomly selected, and 546 participants aged ≥100 years were totally involved. A standardized questionaire was used to collect the information of demographic characteristics, life styles, disease history, etc. Cognitive function was evaluated using the Mini Mental State Examination Scale. Arterial oxygen saturation and heart rate were measured by pulse oximetry. Differences in cognitive function between the low SpO2 group (cognitive function. The total score of cognitive function was 22.6±9.7 for the 1 922 participants in the normal SpO2 group, and 18.8 ± 11.0 for the 363 participants in the low SpO2 group (t=6.11, Pcognitive impairment in the low SpO2 group was 36.6% (n=133), and 22.9% (n=441) in the normal SpO2 group (χ(2)=30.44, Pcognitive impairment increased with each year of increased age (OR 1.07; (95% CI: 1.05-1.09), Pcognitive impairment (OR 1.64; (95% CI: 1.11-2.43), OR 1.73; (95% CI: 1.27-2.35), OR 3.54; (95% CI: 2.62-4.79), OR 1.38; (95% CI: 1.02-1.86), OR 2.05; (95% CI: 1.34-3.13), OR 1.83; (95% CI: 1.13-2.97), respectively, Page group showed that the association between SpO2 and cognitive impairment was most significant in participants aged ≥90 years (OR 1.58; (95% CI: 1.09-2.28), P=0.016). Low oxygen saturation was associated with higher risk of cognitive impairment in our population of elderly adults.

  15. In vivo integrated photoacoustic and confocal microscopy of hemoglobin oxygen saturation and oxygen partial pressure.

    Science.gov (United States)

    Wang, Yu; Hu, Song; Maslov, Konstantin; Zhang, Yu; Xia, Younan; Wang, Lihong V

    2011-04-01

    We developed dual-modality microscope integrating photoacoustic microscopy (PAM) and fluorescence confocal microscopy (FCM) to noninvasively image hemoglobin oxygen saturation (sO₂) and oxygen partial pressure (pO₂) in vivo in single blood vessels with high spatial resolution. While PAM measures sO₂ by imaging hemoglobin optical absorption at two wavelengths, FCM quantifies pO₂ using phosphorescence quenching. The variations of sO₂ and pO₂ values in multiple orders of vessel branches under hyperoxic (100% oxygen) and normoxic (21% oxygen) conditions correlate well with the oxygen-hemoglobin dissociation curve. In addition, the total concentration of hemoglobin is imaged by PAM at an isosbestic wavelength.

  16. Pulse oximetry recorded from the Phone Oximeter for detection of obstructive sleep apnea events with and without oxygen desaturation in children.

    Science.gov (United States)

    Garde, Ainara; Dehkordi, Parastoo; Wensley, David; Ansermino, J Mark; Dumont, Guy A

    2015-01-01

    Obstructive sleep apnea (OSA) disrupts normal ventilation during sleep and can lead to serious health problems in children if left untreated. Polysomnography, the gold standard for OSA diagnosis, is resource intensive and requires a specialized laboratory. Thus, we proposed to use the Phone Oximeter™, a portable device integrating pulse oximetry with a smartphone, to detect OSA events. As a proportion of OSA events occur without oxygen desaturation (defined as SpO2 decreases ≥ 3%), we suggest combining SpO2 and pulse rate variability (PRV) analysis to identify all OSA events and provide a more detailed sleep analysis. We recruited 160 children and recorded pulse oximetry consisting of SpO2 and plethysmography (PPG) using the Phone Oximeter™, alongside standard polysomnography. A sleep technician visually scored all OSA events with and without oxygen desaturation from polysomnography. We divided pulse oximetry signals into 1-min signal segments and extracted several features from SpO2 and PPG analysis in the time and frequency domain. Segments with OSA, especially the ones with oxygen desaturation, presented greater SpO2 variability and modulation reflected in the spectral domain than segments without OSA. Segments with OSA also showed higher heart rate and sympathetic activity through the PRV analysis relative to segments without OSA. PRV analysis was more sensitive than SpO2 analysis for identification of OSA events without oxygen desaturation. Combining SpO2 and PRV analysis enhanced OSA event detection through a multiple logistic regression model. The area under the ROC curve increased from 81% to 87%. Thus, the Phone Oximeter™ might be useful to monitor sleep and identify OSA events with and without oxygen desaturation at home.

  17. Lack of differences in the regional variation of oxygen saturation in larger retinal vessels in diabetic maculopathy and proliferative diabetic retinopathy.

    Science.gov (United States)

    Jørgensen, Christina Mørup; Bek, Toke

    2017-06-01

    Diabetic retinopathy is characterised by morphological lesions in the ocular fundus related to disturbances in retinal blood flow. The two vision threatening forms of retinopathy show specific patterns of distribution of retinal lesions with proliferative diabetic retinopathy (PDR) developing secondary to ischaemia and hypoxia in the retinal periphery and diabetic maculopathy (DM) developing secondary to hyperperfusion and increased vascular permeability in the macular area. These differences in the distribution of retinal lesions might be reflected in regional differences in oxygen saturation in the larger retinal vessels. Dual-wavelength retinal oximetry was performed in 30 normal persons, 30 patients with DM and 30 patients with PDR, and the oxygen saturation was measured in peripapillary vessels supplying the four retinal quadrants and in branches from the upper temporal arcades supplying, respectively, the macular area and the retinal periphery. The overall oxygen saturation was significantly higher in diabetic patients than in normal persons and the arteriovenous (AV) saturation difference significantly lower in the patients with DM. The regional variation in oxygen saturation was similar in the three studied groups with a decreasing saturation from the upper nasal through the lower nasal, lower temporal and the upper temporal peripapillary vessels, and with a significantly higher oxygen saturation in venules draining the macular area than in venules draining the retinal periphery. The regional differences in retinal lesions in vision threatening diabetic retinopathy are not reflected in regional differences in the oxygen saturation of larger retinal vessels. The development of vision threatening diabetic retinopathy depends on other factors, such as, for example, regional differences in the retinal microcirculation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Optical noninvasive calculation of hemoglobin components concentrations and fractional oxygen saturation using a ring-scattering pulse oximeter

    Science.gov (United States)

    Abdallah, Omar; Stork, Wilhelm; Muller-Glaser, Klaus

    2004-06-01

    The deficiencies of the currently used pulse oximeter are discussed in diverse literature. A hazardous pitfalls of this method is that the pulse oximeter will not detect carboxyhemoglobin (COHb) and methemoglobin (metHb) concentrations. This leads to incorrect measurement of oxygen saturation by carbon monoxide poisoning and methemoglobinemia. Also the total hemoglobin concentration will not be considered and can only be measured in-vitro up to now. A second pitfall of the standard pulse oximetry is that it will not be able to show a result by low perfusion of tissues. This case is available inter alia when the patient is under shock or has a low blood pressure. The new non-invasive system we designed measures the actual (fractional) oxygen saturation and hemoglobin concentration. It will enable us also to measure COHb and metHb. The measurement can be applied at better perfused body central parts. Four or more light emitting diodes (LEDs) or laser diodes (LDs) and five photodiodes (PDs) are used. The reflected light signal detected by photodiodes is processed using a modified Lambert-Beer law (I=I0×e-α.d ). According to this law, when a non scattering probe is irradiated with light having the incident intensity I0, the intensity of transmitted light I decays exponentially with the absorption coefficient a of that probe and its thickness d. Modifications of this law have been performed following the theoretical developed models in literature, Monte Carlo simulation and experimental measurement.

  19. Cerebral Oximetry in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    A. N. Shepelyuk

    2012-01-01

    Full Text Available Based on the data of numerous current references, the review describes different neuromonitoring methods during cardiac surgery under extracorporeal circulation. It shows that it is important and necessary to make neuromonitoring for the early diagnosis and prevention of neurological complications after cardiac surgery. Particular attention is given to cerebral oximetry; the possibilities and advantages of this technique are described. Correction of cerebral oximetric values is shown to improve survival rates and to reduce the incidence of postoperative complications. Lack of cerebral oximetry monitoring denudes a clinician of important information and possibilities to optimize patient status and to prevent potentially menacing complications, which allows one to conclude that it is necessary to use cerebral oximetry procedures within neu-romonitoring in cardiac surgery. Key words: extracorporeal circulation, cerebral oximetry, neurological dysfunction, cerebral oxygenation.

  20. An applicable approach for extracting human heart rate and oxygen saturation during physical movements using a multi-wavelength illumination optoelectronic sensor system

    Science.gov (United States)

    Alharbi, Samah; Hu, Sijung; Mulvaney, David; Blanos, Panagiotis

    2018-02-01

    The ability to gather physiological parameters such as heart rate (HR) and oxygen saturation (SpO2%) during physical movement allows to continuously monitor personal health status without disrupt their normal daily activities. Photoplethysmography (PPG) based pulse oximetry and similar principle devices are unable to extract the HR and SpO2% reliably during physical movement due to interference in the signals that arise from motion artefacts (MAs). In this research, a flexible reflectance multi-wavelength optoelectronic patch sensor (OEPS) has been developed to overcome the susceptibility of conventional pulse oximetry readings to MAs. The OEPS incorporates light embittered diodes as illumination sources with four different wavelengths, e.g. green, orange, red, and infrared unlike the conventional pulse oximetry devices that normally measure the skin absorption of only two wavelengths (red and infrared). The additional green and orange wavelengths were found to be distinguish to the absorption of deoxyhemoglobin (RHb) and oxyhemoglobin (HbO2). The reliability of extracting physiological parameters from the green and orange wavelengths is due to absorbed near to the surface of the skin, thereby shortening the optical path and so effectively reducing the influence of physical movements. To compensate of MAs, a three-axis accelerometer was used as a reference with help of adaptive filter to reduce MAs. The experiments were performed using 15 healthy subjects aged 20 to 30. The primary results show that there are no significant difference of heart rate and oxygen saturation measurements between commercial devices and OEPS Green (r=0.992), Orange(r=0.984), Red(r=0.952) and IR(r=0.97) and SpO2% (r = 0.982, p = 0.894).

  1. Dynamic changes in oxygenation of intracranial tumor and contralateral brain during tumor growth and carbogen breathing: A multisite EPR oximetry with implantable resonators

    Science.gov (United States)

    Hou, Huagang; Dong, Ruhong; Li, Hongbin; Williams, Benjamin; Lariviere, Jean P.; Hekmatyar, S.K.; Kauppinen, Risto A.; Khan, Nadeem; Swartz, Harold

    2013-01-01

    Introduction Several techniques currently exist for measuring tissue oxygen; however technical difficulties have limited their usefulness and general application. We report a recently developed electron paramagnetic resonance (EPR) oximetry approach with multiple probe implantable resonators (IRs) that allow repeated measurements of oxygen in tissue at depths of greater than 10 mm. Methods The EPR signal to noise (S/N) ratio of two probe IRs was compared with that of LiPc deposits. The feasibility of intracranial tissue pO2 measurements by EPR oximetry using IRs was tested in normal rats and rats bearing intracerebral F98 tumors. The dynamic changes in the tissue pO2 were assessed during repeated hyperoxia with carbogen breathing. Results A 6–10 times increase in the S/N ratio was observed with IRs as compared to LiPc deposits. The mean brain pO2 of normal rats was stable and increased significantly during carbogen inhalation in experiments repeated for 3 months. The pO2 of F98 glioma declined gradually, while the pO2 of contralateral brain essentially remained the same. Although a significant increase in the glioma pO2 was observed during carbogen inhalation, this effect declined in experiments repeated over days. Conclusion EPR oximetry with IRs provides a significant increase in S/N ratio. The ability to repeatedly assess orthotopic glioma pO2 is likely to play a vital role in understanding the dynamics of tissue pO2 during tumor growth and therapies designed to modulate tumor hypoxia. This information could then be used to optimize chemoradiation by scheduling treatments at times of increased glioma oxygenation. PMID:22033225

  2. Clinical score and arterial oxygen saturation in children with wheezing associated respiratory illness (WARI).

    Science.gov (United States)

    Sritippayawan, S; Deerojanawong, J; Prapphal, N

    2000-10-01

    To determine the correlation between clinical score (based on respiratory rate, chest wall retractions, air entry, wheezing, consciousness and audible wheezing) and arterial oxygen saturation (SaO2: measured by pulse oximetry) as well as the most appropriate total score for predicting hypoxemia (SaO2 WARI). 70 children (1 month-5 years old) hospitalized in the Department of Pediatrics, Chulalongkorn Hospital with the diagnosis of WARI from January 1, 1996 to December 31, 1996 were studied. Half of them were diagnosed to have acute lower respiratory tract infection (LRI) with wheezing while the remainder had reactive airway disease (RAD). Cross sectional, analytical study. In each group of patients, the clinical score and SaO2 were assessed by the same pediatrician throughout the study. The correlation between the clinical signs and SaO2 as well as the cut off point of total score for predicting hypoxemia were analyzed. The sensitivity, specificity and accuracy of that total score in predicting hypoxemia were also calculated. In both groups of patients (acute LRI with wheezing and RAD group), the clinical signs correlated with SaO2 were wheezing (rs = -0.67 and -0.47 respectively) and chest wall retractions (rs = -0.57 and -0.59 respectively). Total score was also correlated with SaO2 (rs = -0.68 and -0.5 respectively). The cut off point of total score in predicting hypoxemia was 4 providing 80 per cent sensitivity in both groups with accuracy 74.3 per cent and 80 per cent respectively. This clinical score may be used to assess the severity of hypoxemia in WARI patients. Wheezing, chest wall retractions and total score correlated well with SaO2. The total score > 4 was most appropriate in predicting hypoxemia in both children with RAD and wheezing associated with LRI.

  3. EFFECTIVENESS OF AUTOGENIC DRAINAGE VERSUS POSTURAL DRAINAGE ON OXYGEN SATURATION IN PATIENTS WITH CHRONIC BRONCHITIS WITH 15 MINUTES POST THERAPY

    Directory of Open Access Journals (Sweden)

    V. Kiran

    2014-12-01

    Full Text Available Background: Patients with COPD will have more amount of secretions. To clear the secretions by using of different bronchial hygiene techniques like postural drainage and autogenic drainage technique, manual hyperventilation technique ,active cycle breathing technique .Hence in this study to compare the short-term effects of postural drainage with clapping (PD and autogenic drainage (AD on level of oxygen saturation in blood, and amount of sputum recovery. Methodology: The study was done on 60 patients with COPD. Dividing Patients into two group and patients were treated with PD or AD in separate Groups. The effectiveness of the treatment was measured up to 6 days. Pulse oximetry was monitored and sputum was collected immediately after treatment and 15 minutes following each treatment. Results: The results of the study shown that there was significant difference in the amount of sputum recovered with AD (14.0±3.5 g vs PD (24.4±3.0 g and significant differences in Oxygen saturation; during PD fell from 93.3±0.7% to 91.2±0.8% (p<0.01 and required 15 min following treatment to return to baseline. Oxygen saturation did not fall during AD and increased to gradually following complete treatment days (baseline, 93.3±0.8%; p<0.01. Conclusion: Hence this study concludes that Autogenic drainage is more effective in improving spo2 in COPD & does not cause a sudden fall in spo2 as occurs in Postural drainage immediately after therapy. And it can be better tolerated by patients with COPD while producing fewer benefits in sputum clearance. In concern to mean amount of secretion removal Postural is found to be more effective

  4. Developmental Effects Determine Submaximal Arterial Oxygen Saturation in Peruvian Quechua.

    Science.gov (United States)

    Kiyamu, Melisa; León-Velarde, Fabiola; Rivera-Chira, María; Elías, Gianpietro; Brutsaert, Tom D

    2015-06-01

    Kiyamu, Melisa, Fabiola León-Velarde, María Rivera-Chira, Gianpietro Elías, and Tom D. Brutsaert. Developmental effects determine submaximal arterial oxygen saturation in Peruvian Quechua. High Alt Med Biol 16, 138-146, 2015.--Andean high altitude natives show higher arterial oxygen saturation (Sao(2)) during exercise in hypoxia, compared to acclimatized sojourners. In order to evaluate the effects of life-long exposure to high altitude on Sao(2), we studied two groups of well-matched, self-identified Peruvian Quechua natives who differed in their developmental exposure to hypoxia before and after a 2-month training period. Male and female volunteers (18-35 years) were recruited in Lima, Peru (150 m). The two groups were: a) Individuals who were born and raised at sea-level (BSL, n=34) and b) Individuals who were born and raised at high altitude (BHA, n=32), but who migrated to sea-level as adults (>16 years old). Exercise testing was conducted using a submaximal exercise protocol in normobaric hypoxia in Lima (BP=750 mmHg, Fio(2)=0.12), in order to measure Sao(2) (%), ventilation (VE L/min) and oxygen consumption (Vo(2), L/min). Repeated-measures ANOVA, controlling for VE/VO(2) (L/min) and sex during the submaximal protocol showed that BHA maintained higher Sao(2) (%) compared to BSL at all workloads before (p=0.005) and after training (p=0.017). As expected, both groups showed a decrease in Sao(2) (%) (p<0.001), as workload increased. Resting Sao(2) levels were not found to be different between groups. The results suggest that developmental exposure to altitude contributes to the maintenance of higher Sao(2) levels during submaximal exercise at hypoxia.

  5. Investigating Functional Extension of Optical Coherence Tomography for Spectroscopic Analysis of Blood Oxygen Saturation

    Science.gov (United States)

    Chen, Siyu

    Over the past two decades, optical coherence tomography (OCT) has been successfully applied to various fields of biomedical researching and clinical studies, including cardiology, urology, dermatology, dentistry, oncology, and most successfully, ophthalmology. This dissertation seeks to extend the current OCT practice, which is still largely morphology-based, into a new dimension, functional analysis of metabolic activities in vivo. More specifically, the investigation is focused on retrieving blood oxygen saturation (sO2) using intrinsic hemoglobin optical absorption contrast. Most mammalian cells rely on aerobic respiration to support cellular function, which means they consume oxygen to create adenosine triphosphate (ATP). Metabolic rate of oxygen (MRO2), a key hemodynamic parameter, characterizes how much oxygen is consumed during a given period of time, reflecting the metabolic activity of the target tissue. For example, retinal neurons are highly active and almost entirely rely on the moment-to-moment oxygen supply from retinal circulations. Thus, variation in MRO2 reveals the instantaneous activity of these neurons, shedding light on the physiological and pathophysiological change of cellular functions. Eventually, measuring MRO2 can potentially provide a biomarker for early-stage disease diagnosis, and serve as one benchmark for evaluating effectiveness of medical intervention during disease management. Essential in calculating MRO2, blood sO2 measurements using spectroscopic OCT analysis has been attempted as early as 2003. OCT is intrinsically sensitive to the blood optical absorption spectrum due to its wide-band illumination and detection scheme relying on back-scattered photon. However, accurate retrieval of blood sO2 using conventional near infrared (NIR) OCT systems in vivo has remained challenging. It was not until the development of OCT systems using visible light illumination (vis-OCT) when accurate measurement of blood sO2 was reported in live

  6. [Tissue oxygen saturation in the critically ill patient].

    Science.gov (United States)

    Gruartmoner, G; Mesquida, J; Baigorri, F

    2014-05-01

    Hemodynamic resuscitation seeks to correct global macrocirculatory parameters of pressure and flow. However, current evidence has shown that despite the normalization of these global parameters, microcirculatory and regional perfusion alterations can persist, and these alterations have been independently associated with a poorer patient prognosis. This in turn has lead to growing interest in new technologies for exploring regional circulation and microcirculation. Near infra-red spectroscopy allows us to monitor tissue oxygen saturation, and has been proposed as a noninvasive, continuous and easy-to-obtain measure of regional circulation. The present review aims to summarize the existing evidence on near infra-red spectroscopy and its potential clinical role in the resuscitation of critically ill patients in shock. Copyright © 2013 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  7. Low FEV1, smoking history, and obesity are factors associated with oxygen saturation decrease in an adult population cohort

    Directory of Open Access Journals (Sweden)

    Vold ML

    2014-10-01

    Full Text Available Monica Linea Vold,1,3 Ulf Aasebø,1,2 Hasse Melbye3 1Department of Respiratory Medicine, University Hospital of North Norway, 2Department of Clinical Medicine, 3Department of Community Medicine, University of Tromsø, Tromsø, Norway Background: Worsening of pulmonary diseases is associated with a decrease in oxygen saturation (SpO2. Such a decrease in SpO2 and associated factors has not been previously evaluated in a general adult population. Aim: We sought to describe SpO2 in a sample of adults, at baseline and after 6.3 years, to determine whether factors predicting low SpO2 in a cross-sectional study were also associated with a decrease in SpO2 in this cohort. Methods: As part of the Tromsø Study, 2,822 participants were examined with pulse oximetry in Tromsø 5 (2001/2002 and Tromsø 6 (2007/2008. Low SpO2 by pulse oximetry was defined as an SpO2 ≤95%, and SpO2 decrease was defined as a ≥2% decrease from baseline to below 96%. Results: A total of 139 (4.9% subjects had a decrease in SpO2. Forced expiratory volume in 1 second (FEV1 <50% of the predicted value and current smoking with a history of ≥10 pack-years were the baseline characteristics most strongly associated with an SpO2 decrease in multivariable logistic regression (odds ratio 3.55 [95% confidence interval (CI 1.60–7.89] and 2.48 [95% CI 1.48–4.15], respectively. Male sex, age, former smoking with a history of ≥10 pack-years, body mass index ≥30 kg/m2, and C-reactive protein ≥5 mg/L were also significantly associated with an SpO2 decrease. A significant decrease in FEV1 and a new diagnosis of asthma or chronic obstructive pulmonary disease during the observation period most strongly predicted a fall in SpO2. A lower SpO2 decrease was observed in those who quit smoking and those who lost weight, but these tendencies were not statistically significant. Conclusion: A decrease in SpO2 was most strongly associated with severe airflow limitation and a history of

  8. Cerebral Oxygenation of the Cortex and Striatum following Normobaric Hyperoxia and Mild Hypoxia in Rats by EPR Oximetry using Multi-Probe Implantable Resonators

    Science.gov (United States)

    Hou, Huagang; Li, Hongbin; Dong, Ruhong; Mupparaju, Sriram; Khan, Nadeem; Swartz, Harold

    2013-01-01

    Multi-site electron paramagnetic resonance (EPR) oximetry, using multi-probe implantable resonators, was used to measure the partial pressure of oxygen (pO2) in the brains of rats following normobaric hyperoxia and mild hypoxia. The cerebral tissue pO2 was measured simultaneously in the cerebral cortex and striatum in the same rats before, during, and after normobaric hyperoxia and mild hypoxia challenges. The baseline mean tissue pO2 values (±SE) were not significantly different between the cortex and striatum. During 30 min of 100% O2 inhalation, a statistically significant increase in tissue pO2 of all four sites was observed, however, the tissue pO2 of the striatum area was significantly higher than in the forelimb area of the cortex. Brain pO2 significantly decreased from the baseline value during 15 min of 15% O2 challenge. No differences in the recovery of the cerebral cortex and striatum pO2 were observed when the rats were allowed to breathe 30% O2. It appears that EPR oximetry using implantable resonators can provide information on pO2 under the experimental conditions needed for such a study. The levels of pO2 that occurred in these experiments are readily resolvable by multi-site EPR oximetry with multi-probe resonators. In addition, the ability to simultaneously measure the pO2 in several areas of the brain provides important information that could potentially help differentiate the pO2 changes that can occur due to global or local mechanisms. PMID:21445770

  9. Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.

    Directory of Open Access Journals (Sweden)

    Wouter B Vehmeijer

    Full Text Available Dual wavelength retinal oximetry has been developed for adults, but is not available for infants. Retinal oximetry may provide insight into the pathophysiology of oxygen-mediated diseases like retinopathy of prematurity. More insight in the oxygen metabolism of the retina in infants may provide valuable clues for better understanding and subsequent prevention or treatment of the disease. The measurements of oxygen saturation are obtained with two fundus images simultaneously captured in two different wavelengths of light. The comparison in light absorption of oxygenated and deoxygenated hemoglobin can be used to estimate the oxygen saturation within the retinal vessels by means of a software algorithm. This study aims to make retinal oximetry available for neonates. The first step towards estimating retinal oxygen saturation is determining the optical density ratio. Therefore, the purpose of this study is to image healthy newborn infants with a scanning laser ophthalmoscope and determine the optical density ratio for retinal oximetry analysis.Images of the retina of full-term healthy infants were obtained with an SLO, Optomap 200Tx (Optos, with two laser wavelengths (532nm and 633nm. The infant lay face down on the lower arm of the parent, while the parent supported the chest and chin with one hand, and stabilized the back with the other hand. No mydriatics or eyelid specula were used during this study. The images were analyzed with modified Oxymap Analyzer software for calculation of the Optical Density Ratio (ODR and vessel width. The ODR is inversely and approximately linearly related to the oxygen saturation. Measurements were included from the superotemporal vessel pair. A paired t-test was used for statistical analysis.Fifty-nine infants, (58% female, were included with mean gestational age of 40 ± 1.3 weeks (mean ± SD and mean post-natal age of 16 ± 4.8 days. A total of 28 images were selected for retinal oximetry analysis. The ODR was

  10. Closed Loop Control of Oxygen Delivery and Oxygen Generation

    Science.gov (United States)

    2017-08-01

    were used for this study and were connected via a USB cable to allow communication. The ventilator was modified to allow closed loop control of oxygen...connected via a USB cable to allow communication. The ventilator was modified to allow closed loop control of oxygen based on the oxygen saturation...2017-4119, 28 Aug 2017. oximetry (SpO2) and intermittent arterial blood sampling for arterial oxygen tension (partial pressure of oxygen [PaO2]) and

  11. Compliance in oxygen saturation targeting in preterm infants : a systematic review

    NARCIS (Netherlands)

    van Zanten, Henriëtte A; Tan, Ratna N G B; van den Hoogen, Agnes; Lopriore, Enrico; te Pas, Arjan B

    2015-01-01

    UNLABELLED: During oxygen therapy in preterm infants, targeting oxygen saturation is important for avoiding hypoxaemia and hyperoxaemia, but this can be very difficult and challenging for neonatal nurses. We systematically reviewed the qualitative and quantitative studies investigating the

  12. Cerebral oximetry in preterm infants

    DEFF Research Database (Denmark)

    Greisen, Gorm; Andresen, Bjørn; Plomgaard, Anne Mette

    2016-01-01

    Preterm birth constitutes a major cause of death before 5 years of age and it is a major cause of neurodevelopmental impairment across the world. Preterm infants are most unstable during the transition between fetal and newborn life during the first days of life and most brain damage occurs...... in this period. The brain of the preterm infant is accessible for tissue oximetry by near-infrared spectroscopy. Cerebral oximetry has the potential to improve the long-term outcome by helping to tailor the support of respiration and circulation to the individual infant's needs, but the evidence is still lacking....... The goals for research include testing the benefit and harms of cerebral oximetry in large-scale randomized trials, improved definition of the hypoxic threshold, better understanding the effects of intensive care on cerebral oxygenation, as well as improved precision of oximeters and calibration among...

  13. Correlation between Oxygen Saturation and Hemoglobin and Hematokrit Levels in Tetralogy of Fallot Patients

    Directory of Open Access Journals (Sweden)

    Farhatul Inayah Adiputri

    2016-03-01

    Full Text Available Background: Hemoglobin and hematocrit levels increase in Tetralogy of Fallot (TOF but the oxygen saturation declines. Reduced hemoglobin in circulating blood as a parameter of cyanosis does not indicate rising hemoglobin due to the ‘not-working’ hemoglobins that affect the oxygen saturation. Increasing hematocrit is the result of secondary erythrocytosis caused by declining oxygen level in blood, which is related to the oxygen saturation. This study was conducted to find the correlation between oxygen saturation and hemoglobin and hematocrite levels in TOF patients. Methods: This study was undertaken at Dr. Hasan Sadikin General Hospital in the period of January 2011 to December 2012 using the cross-sectional analytic method with total sampling technique. Inclusion criteria were medical records of TOF patients diagnosed based on echocardiography that included data on oxygen saturation, hemoglobin, and hematocrite. Exclusion criteria was the history of red blood transfusion. Results: Thirty medical records of TOF patiens from Dr. Hasan Sadikin General Hospital Bandung were included in this study. Due to skewed data distribution, Spearman correlation test was used to analyze the data. There was a significant negative correlation between oxygen saturation and hematocrit level (r= -0.412; p=0.024 and insignificant correlation between oxygen saturation and hemoglobin (r=-0.329; p= 0.076. Conclusions: There is a weak negative correlation between oxygen saturation and hematocrite levels

  14. Photonic textiles for pulse oximetry.

    Science.gov (United States)

    Rothmaier, Markus; Selm, Bärbel; Spichtig, Sonja; Haensse, Daniel; Wolf, Martin

    2008-08-18

    Biomedical sensors, integrated into textiles would enable monitoring of many vitally important physiological parameters during our daily life. In this paper we demonstrate the design and performance of a textile based pulse oximeter, operating on the forefinger tip in transmission mode. The sensors consisted of plastic optical fibers integrated into common fabrics. To emit light to the human tissue and to collect transmitted light the fibers were either integrated into a textile substrate by embroidery (producing microbends with a nominal diameter of 0.5 to 2 mm) or the fibers inside woven patterns have been altered mechanically after fabric production. In our experiments we used a two-wavelength approach (690 and 830 nm) for pulse wave acquisition and arterial oxygen saturation calculation. We have fabricated different specimens to study signal yield and quality, and a cotton glove, equipped with textile based light emitter and detector, has been used to examine movement artifacts. Our results show that textile-based oximetry is feasible with sufficient data quality and its potential as a wearable health monitoring device is promising.

  15. The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation

    International Nuclear Information System (INIS)

    Budidha, K; Kyriacou, P A

    2014-01-01

    For the last two decades, pulse oximetry has been used as a standard procedure for monitoring arterial oxygen saturation (SpO 2 ). However, SpO 2 measurements made from extremities such as the finger, ear lobe and toes become susceptible to inaccuracies when peripheral perfusion is compromised. To overcome these limitations, the external auditory canal has been proposed as an alternative monitoring site for estimating SpO 2 , on the hypothesis that this central site will be better perfused. Therefore, a dual wavelength optoelectronic probe along with a processing system was developed to investigate the suitability of measuring photoplethysmographic (PPG) signals and SpO 2 in the human auditory canal. A pilot study was carried out in 15 healthy volunteers to validate the feasibility of measuring PPGs and SpO 2  from the ear canal (EC), and comparative studies were performed by acquiring the same signals from the left index finger (LIF) and the right index finger (RIF) in conditions of induced peripheral vasoconstriction (right hand immersion in ice water). Good quality baseline PPG signals with high signal-to-noise ratio were obtained from the EC, the LIF and the RIF sensors. During the ice water immersion, significant differences in the amplitude of the red and infrared PPG signals were observed from the RIF and the LIF sensors. The average drop in amplitude of red and infrared PPG signals from the RIF was 52.7% and 58.3%. Similarly, the LIF PPG signal amplitudes have reduced by 47.52% and 46.8% respectively. In contrast, no significant changes were seen in the red and infrared EC PPG amplitude measurements, which changed by +2.5% and −1.2% respectively. The RIF and LIF pulse oximeters have failed to estimate accurate SpO 2  in seven and four volunteers respectively, while the EC pulse oximeter has only failed in one volunteer. These results suggest that the EC may be a suitable site for reliable monitoring of PPGs and SpO 2 s even in the presence of

  16. Low pO2 Contributes to Potential Error in Oxygen Saturation Calculations Using a Point-of-Care Assay.

    Science.gov (United States)

    Gunsolus, Ian L; Love, Sara A; Kohl, Louis P; Schmidt, Martin; Apple, Fred S

    2017-12-20

    The present study addressed the accuracy of calculated oxygen saturation (sO2) using point-of-care (POC) testing compared with measured values on a blood gas analyzer. In total, 3,323 sO2 values were measured in 1,180 patients using a CO-oximeter (ABL 800 Flex; Radiometer, Copenhagen, Denmark). Measured parameters were then used to calculate an expected sO2 for the POC method (Abbott i-STAT; Abbott POC, Princeton, NJ). Cases in which calculated sO2 differed from measured sO2 by 10% or more were analyzed. Of the 3,323 comparisons performed, 260 (8%) showed discrepancies (± ≥10%) between measured and calculated sO2 values. Ninety-four of discrepant measurements (245 of 260) occurred when pO2 was less than 50 mm Hg. pH and bicarbonate distributions shifted to lower values in discrepant vs nondiscrepant cases. Our results suggest that the likelihood of discrepant sO2 is 27% among patients with pO2 less than 50 mm Hg. Direct measurement of sO2 by CO-oximetry is strongly suggested in this clinical scenario. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  17. [Regional cerebral oxygen saturation as a marker of hemodynamic state following cardiac surgery].

    Science.gov (United States)

    García-Hernández, J A; Aldemira-Liz, A; Martínez-López, A I; Cayuela, A; Charlo-Molina, M T; Cano-Franco, J; Loscertales-Abril, M

    2013-10-01

    Regional cerebral oxygen saturation (rSO₂) is a measure of the general state of perfusion and oxygenation. We aim to analyze the relationship between this and various hemodynamic and respiratory parameters. Forty-three patients, operated on between October 2011 and July 2012, were included in this prospective observational descriptive study. The following parameters were measured: mean arterial pressure, both arterial and central venous oxygen saturation and partial pressures of oxygen and carbon dioxide, and lactate levels. From these parameters, the oxygenation index and the oxygen extraction ratio were calculated. These measurements were studied to evaluate whether rSO₂ correlated significantly with the other parameters. The average age and weight of the patients were 27.3 months and 9.2 kg, respectively. The rSO₂ correlated positively with both central venous oxygen saturation (r=0.73, P 0.4) between the rSO₂ and central venous oxygen saturation, and between the rSO₂ and oxygen extraction ratio. Regional cerebral oxygen saturation correlates well with hemodynamic parameters - mean arterial pressure, venous saturation, and the tissue oxygen extraction. However, it does not correlate with respiratory parameters. Copyright © 2012 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  18. Monitor hemoglobin concentration and oxygen saturation in living mouse tail using photoacoustic CT scanner

    Science.gov (United States)

    Liu, Bo; Kruger, Robert; Reinecke, Daniel; Stantz, Keith M.

    2010-02-01

    Purpose: The purpose of this study is to use PCT spectroscopy scanner to monitor the hemoglobin concentration and oxygen saturation change of living mouse by imaging the artery and veins in a mouse tail. Materials and Methods: One mouse tail was scanned using the PCT small animal scanner at the isosbestic wavelength (796nm) to obtain its hemoglobin concentration. Immediately after the scan, the mouse was euthanized and its blood was extracted from the heart. The true hemoglobin concentration was measured using a co-oximeter. Reconstruction correction algorithm to compensate the acoustic signal loss due to the existence of bone structure in the mouse tail was developed. After the correction, the hemoglobin concentration was calculated from the PCT images and compared with co-oximeter result. Next, one mouse were immobilized in the PCT scanner. Gas with different concentrations of oxygen was given to mouse to change the oxygen saturation. PCT tail vessel spectroscopy scans were performed 15 minutes after the introduction of gas. The oxygen saturation values were then calculated to monitor the oxygen saturation change of mouse. Results: The systematic error for hemoglobin concentration measurement was less than 5% based on preliminary analysis. Same correction technique was used for oxygen saturation calculation. After correction, the oxygen saturation level change matches the oxygen volume ratio change of the introduced gas. Conclusion: This living mouse tail experiment has shown that NIR PCT-spectroscopy can be used to monitor the oxygen saturation status in living small animals.

  19. Optimal spacing between transmitting and receiving optical fibres in reflectance pulse oximetry

    International Nuclear Information System (INIS)

    Hickey, M; Kyriacou, P A

    2007-01-01

    Splanchnic ischaemia can ultimately lead to cellular hypoxia and necrosis, and may well contribute to the development of multiple organ failures and increased mortality. Therefore, it is of utmost importance to monitor abdominal organ blood oxygen saturation (SpO 2 ). Pulse oximetry has been widely accepted as a reliable method for monitoring oxygen saturation of arterial blood. Animal studies have also shown it to be effective in the monitoring of blood oxygen saturation in the splanchnic region. However, commercially available pulse oximeter probes are not suitable for the continuous assessment of SpO 2 in the splanchnic region. Therefore, there is a need for a new sensor technology that will allow the continuous measurement of SpO 2 in the splanchnic area pre-operatively, operatively and post-operatively. For this purpose, a new fibre optic sensor and processing system utilising the principle of reflectance pulse oximetry has been developed. The accuracy in the estimation of SpO 2 in pulse oximetry depends on the quality and amplitude of the photoplethysmographic (PPG) signal and for this reason an experimental procedure was carried out to examine the effect of the source-detector separation distance on the acquired PPG signals, and to ultimately select an optimal separation for the final design of the fibre-optic probe. PPG signals were obtained from the finger for different separation distances between the emitting and detecting fibres. Good quality PPG signals with large amplitudes and high signal-to-noise ratio were detected in the range of 3mm to 6mm. At separation distances between 1mm and 2mm, PPG signals were erratic with no resemblance to a conventional PPG signal. At separation distances greater than 6mm, the amplitudes of PPG signals were very small and not appropriate for processing. This investigation indicates the suitability of optical fibres as a new pulse oximetry sensor for estimating blood oxygen saturation (SpO 2 ) in the splanchnic region

  20. Optimal spacing between transmitting and receiving optical fibres in reflectance pulse oximetry

    Science.gov (United States)

    Hickey, M.; Kyriacou, P. A.

    2007-10-01

    Splanchnic ischaemia can ultimately lead to cellular hypoxia and necrosis, and may well contribute to the development of multiple organ failures and increased mortality. Therefore, it is of utmost importance to monitor abdominal organ blood oxygen saturation (SpO2). Pulse oximetry has been widely accepted as a reliable method for monitoring oxygen saturation of arterial blood. Animal studies have also shown it to be effective in the monitoring of blood oxygen saturation in the splanchnic region. However, commercially available pulse oximeter probes are not suitable for the continuous assessment of SpO2 in the splanchnic region. Therefore, there is a need for a new sensor technology that will allow the continuous measurement of SpO2 in the splanchnic area pre-operatively, operatively and post-operatively. For this purpose, a new fibre optic sensor and processing system utilising the principle of reflectance pulse oximetry has been developed. The accuracy in the estimation of SpO2 in pulse oximetry depends on the quality and amplitude of the photoplethysmographic (PPG) signal and for this reason an experimental procedure was carried out to examine the effect of the source-detector separation distance on the acquired PPG signals, and to ultimately select an optimal separation for the final design of the fibre-optic probe. PPG signals were obtained from the finger for different separation distances between the emitting and detecting fibres. Good quality PPG signals with large amplitudes and high signal-to-noise ratio were detected in the range of 3mm to 6mm. At separation distances between 1mm and 2mm, PPG signals were erratic with no resemblance to a conventional PPG signal. At separation distances greater than 6mm, the amplitudes of PPG signals were very small and not appropriate for processing. This investigation indicates the suitability of optical fibres as a new pulse oximetry sensor for estimating blood oxygen saturation (SpO2) in the splanchnic region.

  1. Non-invasive evaluation of blood oxygen saturation and hematocrit from T1 and T2 relaxation times: In-vitro validation in fetal blood.

    Science.gov (United States)

    Portnoy, Sharon; Seed, Mike; Sled, John G; Macgowan, Christopher K

    2017-12-01

    We propose an analytical method for calculating blood hematocrit (Hct) and oxygen saturation (sO 2 ) from measurements of its T 1 and T 2 relaxation times. Through algebraic substitution, established two-compartment relationships describing R1=T1-1 and R2=T2-1 as a function of hematocrit and oxygen saturation were rearranged to solve for Hct and sO 2 in terms of R 1 and R 2 . Resulting solutions for Hct and sO 2 are the roots of cubic polynomials. Feasibility of the method was established by comparison of Hct and sO 2 estimates obtained from relaxometry measurements (at 1.5 Tesla) in cord blood specimens to ground-truth values obtained by blood gas analysis. Monte Carlo simulations were also conducted to assess the effect of T 1 , T 2 measurement uncertainty on precision of Hct and sO 2 estimates. Good agreement was observed between estimated and ground-truth blood properties (bias = 0.01; 95% limits of agreement = ±0.13 for Hct and sO 2 ). Considering the combined effects of biological variability and random measurement noise, we estimate a typical uncertainty of ±0.1 for Hct, sO 2 estimates. Results demonstrate accurate quantification of Hct and sO 2 from T 1 and T 2 . This method is applicable to noninvasive fetal vessel oximetry-an application where existing oximetry devices are unusable or require risky blood-sampling procedures. Magn Reson Med 78:2352-2359, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. Monitoring Oxygen Levels in Orthotopic Human Glioma Xenograft Following Carbogen Inhalation and Chemotherapy by Implantable Resonator Based Oximetry

    Science.gov (United States)

    Hou, Huagang; Nemani, Venkata Krishnamurthy; Du, Gaixin; Montano, Ryan; Song, Rui; Gimi, Barjor; Swartz, Harold M.; Eastman, Alan; Khan, Nadeem

    2014-01-01

    Hypoxia is a critical hallmark of glioma, and significantly compromises treatment efficacy. Unfortunately, techniques for monitoring glioma pO2 to facilitate translational research are lacking. Furthermore, poor prognoses of patients with malignant glioma, in particular glioblastoma multiforme, warrant effective strategies that can inhibit hypoxia and improve treatment outcome. EPR oximetry using implantable resonators was implemented for monitoring pO2 in normal cerebral tissue and U251 glioma in mice. Breathing carbogen (95% O2 + 5% CO2) was tested for hyperoxia in the normal brain and glioma xenografts. A new strategy to inhibit glioma growth by rationally combining gemcitabine and MK-8776, a cell cycle checkpoint inhibitor, was also investigated. The mean pO2 of left and right hemisphere were approximately 56 – 69 mmHg in the normal cerebral tissue of mice. The mean baseline pO2 of U251 glioma on the first and fifth day of measurement was 21.9 ± 3.7 and 14.1 ± 2.4 mmHg, respectively. The mean brain pO2 including glioma increased by at least 100% on carbogen inhalation, although the response varied between the animals over days. Treatment with gemcitabine + MK-8776 significantly increased pO2 and inhibited glioma growth assessed by MRI. In conclusion, EPR oximetry with implantable resonators can be used to monitor the efficacy of carbogen inhalation and chemotherapy on orthotopic glioma in mice. The increase in glioma pO2 of mice breathing carbogen can be used to improve treatment outcome. The treatment with gemcitabine + MK-8776 is a promising strategy that warrants further investigation. PMID:25111969

  3. Monitoring oxygen levels in orthotopic human glioma xenograft following carbogen inhalation and chemotherapy by implantable resonator-based oximetry.

    Science.gov (United States)

    Hou, Huagang; Krishnamurthy Nemani, Venkata; Du, Gaixin; Montano, Ryan; Song, Rui; Gimi, Barjor; Swartz, Harold M; Eastman, Alan; Khan, Nadeem

    2015-04-01

    Hypoxia is a critical hallmark of glioma, and significantly compromises treatment efficacy. Unfortunately, techniques for monitoring glioma pO2 to facilitate translational research are lacking. Furthermore, poor prognosis of patients with malignant glioma, in particular glioblastoma multiforme, warrant effective strategies that can inhibit hypoxia and improve treatment outcome. EPR oximetry using implantable resonators was implemented for monitoring pO2 in normal cerebral tissue and U251 glioma in mice. Breathing carbogen (95% O2 + 5% CO2 ) was tested for hyperoxia in the normal brain and glioma xenografts. A new strategy to inhibit glioma growth by rationally combining gemcitabine and MK-8776, a cell cycle checkpoint inhibitor, was also investigated. The mean pO2 of left and right hemisphere were ∼56-69 mmHg in the normal cerebral tissue of mice. The mean baseline pO2 of U251 glioma on the first and fifth day of measurement was 21.9 ± 3.7 and 14.1 ± 2.4 mmHg, respectively. The mean brain pO2 including glioma increased by at least 100% on carbogen inhalation, although the response varied between the animals over days. Treatment with gemcitabine + MK-8776 significantly increased pO2 and inhibited glioma growth assessed by MRI. In conclusion, EPR oximetry with implantable resonators can be used to monitor the efficacy of carbogen inhalation and chemotherapy on orthotopic glioma in mice. The increase in glioma pO2 of mice breathing carbogen can be used to improve treatment outcome. The treatment with gemcitabine + MK-8776 is a promising strategy that warrants further investigation. © 2014 UICC.

  4. Repeated assessment of orthotopic glioma pO2 by multi-site EPR oximetry: A technique with the potential to guide therapeutic optimization by repeated measurements of oxygen

    Science.gov (United States)

    Khan, Nadeem; Mupparaju, Sriram; Hou, Huagang; Williams, Benjamin B.; Swartz, Harold

    2011-01-01

    Tumor hypoxia plays a vital role in therapeutic resistance. Consequently, measurements of tumor pO2 could be used to optimize the outcome of oxygen-dependent therapies, such as, chemoradiation. However, the potential optimizations are restricted by the lack of methods to repeatedly and quantitatively assess tumor pO2 during therapies, particularly in gliomas. We describe the procedures for repeated measurements of orthotopic glioma pO2 by multi-site electron paramagnetic resonance (EPR) oximetry. This oximetry approach provides simultaneous measurements of pO2 at more than one site in the glioma and contralateral cerebral tissue. The pO2 of intracerebral 9L, C6, F98 and U251 tumors, as well as contralateral brain, were measured repeatedly for five consecutive days. The 9L glioma was well oxygenated with pO2 of 27 - 36 mm Hg, while C6, F98 and U251 glioma were hypoxic with pO2 of 7 - 12 mm Hg. The potential of multi-site EPR oximetry to assess temporal changes in tissue pO2 was investigated in rats breathing 100% O2. A significant increase in F98 tumor and contralateral brain pO2 was observed on day 1 and day 2, however, glioma oxygenation declined on subsequent days. In conclusion, EPR oximetry provides the capability to repeatedly assess temporal changes in orthotopic glioma pO2. This information could be used to test and optimize the methods being developed to modulate tumor hypoxia. Furthermore, EPR oximetry could be potentially used to enhance the outcome of chemoradiation by scheduling treatments at times of increase in glioma pO2. PMID:22079559

  5. Development of an oxygen saturation measuring system by using near-infrared spectroscopy

    Science.gov (United States)

    Kono, K.; Nakamachi, E.; Morita, Y.

    2017-08-01

    Recently, the hypoxia imaging has been recognized as the advanced technique to detect cancers because of a strong relationship with the biological characterization of cancer. In previous studies, hypoxia imaging systems for endoscopic diagnosis have been developed. However, these imaging technologies using the visible light can observe only blood vessels in gastric mucous membrane. Therefore, they could not detect scirrhous gastric cancer which accounts for 10% of all gastric cancers and spreads rapidly into submucous membrane. To overcome this problem, we developed a measuring system of blood oxygen saturation in submucous membrane by using near-infrared (NIR) spectroscopy. NIR, which has high permeability for bio-tissues and high absorbency for hemoglobin, can image and observe blood vessels in submucous membrane. NIR system with LED lights and a CCD camera module was developed to image blood vessels. We measured blood oxygen saturation using the optical density ratio (ODR) of two wavelengths, based on Lambert-Beer law. To image blood vessel clearly and measure blood oxygen saturation accurately, we searched two optimum wavelengths by using a multilayer human gastric-like phantom which has same optical properties as human gastric one. By using Monte Carlo simulation of light propagation, we derived the relationship between the ODR and blood oxygen saturation and elucidated the influence of blood vessel depth on measuring blood oxygen saturation. The oxygen saturation measuring methodology was validated with experiments using our NIR system. Finally, it was confirmed that our system can detect oxygen saturation in various depth blood vessels accurately.

  6. Measuring arterial oxygenation in a high altitude field environment: comparing portable pulse oximetry with blood gas analysis.

    Science.gov (United States)

    Ross, Elliot M; Matteucci, Michael J; Shepherd, Matthew; Barker, Matthew; Orr, Lance

    2013-06-01

    High altitude environments present unique medical treatment challenges. Medical providers often use small portable pulse oximetry devices to help guide their clinical decision making. A significant body of high altitude research is based on the use of these devices to monitor hypoxia, yet there is a paucity of evidence that these devices are accurate in these environments. We studied whether these devices perform accurately and reliably under true mountain conditions. Healthy unacclimatized active-duty military volunteers participating in mountain warfare training at 2100 m (6900 feet) above sea level were evaluated with several different pulse oximetry devices while in a cold weather, high altitude field environment and then had arterial blood gases (ABG) drawn using an i-STAT for comparison. The pulse oximeter readings were compared with the gold standard ABG readings. A total of 49 individuals completed the study. There was no statistically significant difference between any of the devices and the gold standard of ABG. The best performing device was the PalmSAT (PS) 8000SM finger probe with a mean difference of 2.17% and SD of 2.56 (95% CI, 1.42% to 2.92%). In decreasing order of performance were the PS 8000AA finger probe (mean ± SD, 2.54% ± 2.68%; 95% CI, 1.76% to 3.32%), the PS 8000Q ear probe (2.47% ± 4.36%; 95% CI, 1.21% to 3.75%), the Nonin Onyx 9500 (3.29% ± 3.12%; 95% CI, 2.39% to 4.20%), and finally the PS 8000R forehead reflectance sensor (5.15% ± 2.97%; 95% CI, 4.28% to 6.01%). Based on the results of this study, results of the newer portable pulse oximeters appear to be closely correlated to that of the ABG measurements when tested in true mountain conditions. Copyright © 2013 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  7. Pulse Oximetry

    Science.gov (United States)

    ... This is important to know because when your oxygen level is low, the cells in your body can have a hard time ... level of at least 89% to keep their cells healthy. Having an oxygen level lower than this for a short time is ...

  8. The influence of systemic hemodynamics and oxygen transport on cerebral oxygen saturation in neonates after the Norwood procedure.

    Science.gov (United States)

    Li, Jia; Zhang, Gencheng; Holtby, Helen; Guerguerian, Anne-Marie; Cai, Sally; Humpl, Tilman; Caldarone, Christopher A; Redington, Andrew N; Van Arsdell, Glen S

    2008-01-01

    Ischemic brain injury is an important morbidity in neonates after the Norwood procedure. Its relationship to systemic hemodynamic oxygen transport is poorly understood. Sixteen neonates undergoing the Norwood procedure were studied. Continuous cerebral oxygen saturation was measured by near-infrared spectroscopy. Continuous oxygen consumption was measured by respiratory mass spectrometry. Pulmonary and systemic blood flow, systemic vascular resistance, oxygen delivery, and oxygen extraction ratio were derived with measurements of arterial, and superior vena cava and pulmonary venous gases and pressures at 2- to 4-hour intervals during the first 72 hours in the intensive care unit. Mean cerebral oxygen saturation was 66% +/- 12% before the operation, reduced to 51% +/- 13% on arrival in the intensive care unit, and remained low during the first 8 hours; it increased to 56% +/- 9% at 72 hours, still significantly lower than the preoperative level (P blood flow and oxygen delivery (P blood flow (P = .001) and hemoglobin (P = .02) and negatively correlated with systemic vascular resistance (P = .003). It was not correlated with oxygen consumption (P > .05). Cerebral oxygen saturation decreased significantly in neonates during the early postoperative period after the Norwood procedure and was significantly influenced by systemic hemodynamic and metabolic events. As such, hemodynamic interventions to modify systemic oxygen transport may provide further opportunities to reduce the risk of cerebral ischemia and improve neurodevelopmental outcomes.

  9. Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples

    Science.gov (United States)

    Malik, W. M.

    1967-01-01

    Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.

  10. Low oxygen saturation and severe anemia in compound heterozygous Hb Louisville [β42(CD1)Phe→Leu] and Hb La Desirade [β129(H7)Ala→Val].

    Science.gov (United States)

    Kamseng, Parin; Trakulsrichai, Satariya; Trachoo, Objoon; Yimniam, Walaiporn; Panthan, Bhakbhoom; Jittorntam, Paisan; Niparuck, Pimjai; Sanguanwit, Pitsucha; Wananukul, Winai; Jindadamrongwech, Sumalee

    2017-03-01

    To investigate the cause(s) of a Thai male proband presenting low oxygen saturation by pulse oximetry (SpO 2 ) and severe anemia. As Hb variant was suspected, Hb typing was determined by high-performance liquid chromatography and capillary electrophoresis, and subsequently Hb variant was identified by DNA sequencing. Complete blood counts were performed using automated blood cell counter and oxygen saturation was measured by pulse oximetry. Proband was compound heterozygous for Hb Louisville [β42(CD1)Phe→Leu] and Hb La Desirade [β129(H7)Ala→Val]. Of the proband's two sons, one was compound heterozygous for Hb Louisville and Hb E and the other for Hb La Desirade and Hb E. The former son had similar clinical features and laboratory findings with those of the proband while the latter showed had no abnormal clinical manifestations. This the first report of compound heterozygosity of Hb Louisville and Hb La Desirade in an individual of Southeast Asian ethnicity. Hb variant identification is crucial for genetic counseling and appropriate treatment in regions where hemoglobinopathies are common.

  11. Cerebral tissue oxygen saturation and extraction in preterm infants before and after blood transfusion

    NARCIS (Netherlands)

    van Hoften, Jacorina C. R.; Verhagen, Elise A.; Keating, Paul; ter Horst, Hendrik J.; Bos, Arend F.

    Objective Preterm infants often need red blood cell (RBC) transfusions. The aim of this study was to determine whether haemoglobin levels before transfusion were associated with regional cerebral tissue oxygen saturation (r(c)SO(2)) and fractional tissue oxygen extraction (FTOE) and whether RBC

  12. Reliability of Pulse Oximetry during Progressive Hypoxia, Cardiopulmonary Resuscitation, and Recovery in a Piglet Model of Neonatal Hypoxic Cardiac Arrest.

    Science.gov (United States)

    Hassan, Mohammad Ahmad; Weber, Claudia; Waitz, Markus; Huang, Li; Hummler, Helmut D; Mendler, Marc Robin

    2017-01-01

    Pulse oximetry is widely used in intensive care and emergency conditions to monitor arterial oxygenation and to guide oxygen therapy. To study the reliability of pulse oximetry in comparison with CO-oximetry in newborn piglets during progressive hypoxia, cardiac arrest, cardiopulmonary resuscitation (CPR), and after return of spontaneous circulation (ROSC). Thirty-three newborn piglets were exposed to hypoxia until asystole occurred and then resuscitated until ROSC. Arterial oxygen saturation was monitored continuously by pulse oximetry (SpO2) with one sensor applied to the wrist of the right forelimb (FL) and another to the thigh of the left hind limb (HL). Arterial functional oxygen saturation (SaO2) was measured at baseline and at predefined intervals during each phase of the experiment. SpO2 was compared with coinciding SaO2 values and bias considered whenever the difference (SpO2 - SaO2) was beyond ±5%. Bias values were lower at the baseline measurements (-3.7 ± 2.3% in FL and -4.1 ± 3.4% in HL) as well as after ROSC (1.5 ± 4.2% in FL and 0.2 ± 4.6% in HL) with higher precision and accuracy than during other experiment phases. During hypoxia induction, cardiac arrest, and CPR, there was a marked decrease in precision and accuracy as well as an increase in bias up to 43 ± 26 and 56 ± 27% in FL and HL, respectively, over a range of SaO2 from 13 to 51%. Pulse oximetry showed increased bias and decreased accuracy and precision during marked hypoxemia in a model of neonatal hypoxic cardiac arrest. © 2017 S. Karger AG, Basel.

  13. Prognostic value of cerebral tissue oxygen saturation during neonatal extracorporeal membrane oxygenation.

    Directory of Open Access Journals (Sweden)

    Marie-Philippine Clair

    Full Text Available Extracorporeal membrane oxygenation support is indicated in severe and refractory respiratory or circulatory failures. Neurological complications are typically represented by acute ischemic or hemorrhagic lesions, which induce higher morbidity and mortality. The primary goal of this study was to assess the prognostic value of cerebral tissue oxygen saturation (StcO2 on mortality in neonates and young infants treated with ECMO. A secondary objective was to evaluate the association between StcO2 and the occurrence of cerebral lesions.This was a prospective study in infants < 3 months of age admitted to a pediatric intensive care unit and requiring ECMO support.The assessment of cerebral perfusion was made by continuous StcO2 monitoring using near-infrared spectroscopy (NIRS sensors placed on the two temporo-parietal regions. Neurological lesions were identified by MRI or transfontanellar echography.Thirty-four infants <3 months of age were included in the study over a period of 18 months. The ECMO duration was 10±7 days. The survival rate was 50% (17/34 patients, and the proportion of brain injuries was 20% (7/34 patients. The mean StcO2 during ECMO in the non-survivors was reduced in both hemispheres (p = 0.0008 right, p = 0.03 left compared to the survivors. StcO2 was also reduced in deceased or brain-injured patients compared to the survivors without brain injury (p = 0.002.StcO2 appears to be a strong prognostic factor of survival and of the presence of cerebral lesions in young infants during ECMO.

  14. The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

    Science.gov (United States)

    Laing, R. A.; Danisch, L. A.; Young, L. R.

    1975-01-01

    The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

  15. Effects of spinal immobilization at a 20° angle on cerebral oxygen saturations measured by INVOS™.

    Science.gov (United States)

    Aksel, Gökhan

    2018-01-01

    In this study, we aimed to investigate whether performing the immobilization at 20° instead of 0° changes cerebral oxygenation. 33 volunteers were put in a hard cervical collar and backboard at 0° and immobilized for 30min. The cerebral oxygen saturations of the volunteers were measured at 1, 5, and 30min after the start of the procedure (Group 1). The volunteers were asked to return the day after the Group 1 procedure but at the same time. Serial cerebral oxygen saturations were obtained at the same time intervals as in Group 1, but for Group 2, the backboard was set to 20°. When the cerebral oxygen saturations of the two groups were compared, there was a slight decrease when the backboard position was changed from 0° to 20°, but it was not statistically significant (P=0.220 and P=0.768, respectively). The results revealed that immobilizing the patients with a spinal backboard at 20° instead of 0° did not alter the cerebral oxygen saturations. Our study results revealed that spinal immobilization at 20°, which was a new suggestion for spinal immobilization following a report that this position reduced the decrease in pulmonary function secondary to spinal immobilization, did not alter the cerebral oxygenation, so this suggestion is safe at least from the standpoint of cerebral oxygenation. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Systematic instrumental errors between oxygen saturation analysers in fetal blood during deep hypoxemia.

    Science.gov (United States)

    Porath, M; Sinha, P; Dudenhausen, J W; Luttkus, A K

    2001-05-01

    During a study of artificially produced deep hypoxemia in fetal cord blood, systematic errors of three different oxygen saturation analysers were evaluated against a reference CO oximeter. The oxygen tensions (PO2) of 83 pre-heparinized fetal blood samples from umbilical veins were reduced by tonometry to 1.3 kPa (10 mm Hg) and 2.7 kPa (20 mm Hg). The oxygen saturation (SO2) was determined (n=1328) on a reference CO oximeter (ABL625, Radiometer Copenhagen) and on three tested instruments (two CO oximeters: Chiron865, Bayer Diagnostics; ABL700, Radiometer Copenhagen, and a portable blood gas analyser, i-STAT, Abbott). The CO oximeters measure the oxyhemoglobin and the reduced hemoglobin fractions by absorption spectrophotometry. The i-STAT system calculates the oxygen saturation from the measured pH, PO2, and PCO2. The measurements were performed in duplicate. Statistical evaluation focused on the differences between duplicate measurements and on systematic instrumental errors in oxygen saturation analysis compared to the reference CO oximeter. After tonometry, the median saturation dropped to 32.9% at a PO2=2.7 kPa (20 mm Hg), defined as saturation range 1, and to 10% SO2 at a PO2=1.3 kPa (10 mm Hg), defined as range 2. With decreasing SO2, all devices showed an increased difference between duplicate measurements. ABL625 and ABL700 showed the closest agreement between instruments (0.25% SO2 bias at saturation range 1 and -0.33% SO2 bias at saturation range 2). Chiron865 indicated higher saturation values than ABL 625 (3.07% SO2 bias at saturation range 1 and 2.28% SO2 bias at saturation range 2). Calculated saturation values (i-STAT) were more than 30% lower than the measured values of ABL625. The disagreement among CO oximeters was small but increasing under deep hypoxemia. Calculation found unacceptably low saturation.

  17. Quantitative impact of small angle forward scatter on whole blood oximetry using a Beer-Lambert absorbance model.

    Science.gov (United States)

    LeBlanc, Serge Emile; Atanya, Monica; Burns, Kevin; Munger, Rejean

    2011-04-21

    It is well known that red blood cell scattering has an impact on whole blood oximetry as well as in vivo retinal oxygen saturation measurements. The goal of this study was to quantify the impact of small angle forward scatter on whole blood oximetry for scattering angles found in retinal oximetry light paths. Transmittance spectra of whole blood were measured in two different experimental setups: one that included small angle scatter in the transmitted signal and one that measured the transmitted signal only, at absorbance path lengths of 25, 50, 100, 250 and 500 µm. Oxygen saturation was determined by multiple linear regression in the 520-600 nm wavelength range and compared between path lengths and experimental setups. Mean calculated oxygen saturation differences between setups were greater than 10% at every absorbance path length. The deviations to the Beer-Lambert absorbance model had different spectral dependences between experimental setups, with the highest deviations found in the 520-540 nm range when scatter was added to the transmitted signal. These results are consistent with other models of forward scatter that predict different spectral dependences of the red blood cell scattering cross-section and haemoglobin extinction coefficients in this wavelength range.

  18. Lower early postnatal oxygen saturation target and risk of ductus arteriosus closure failure.

    Science.gov (United States)

    Inomata, Kei; Taniguchi, Shinji; Yonemoto, Hiroki; Inoue, Takeshi; Kawase, Akihiko; Kondo, Yuichi

    2016-11-01

    Early postnatal hyperoxia is a major risk factor for retinopathy of prematurity (ROP) in extremely premature infants. To reduce the occurrence of ROP, we adopted a lower early postnatal oxygen saturation (SpO 2 ) target range (85-92%) from April 2011. Lower SpO 2 target range, however, may lead to hypoxemia and an increase in the risk of ductus arteriosus (DA) closure failure. The aim of this study was therefore to determine whether a lower SpO 2 target range, during the early postnatal stage, increases the risk of DA closure failure. Infants born at closure failure in period 2 (21%) was significantly higher than that in period 1 (1%). On multivariate logistic regression analysis, the lower oxygen saturation target range was an independent risk factor for DA closure failure. Lower early postnatal oxygen saturation target range increases the risk of DA closure failure. © 2016 Japan Pediatric Society.

  19. Pulse oximetry findings in newborns with antenatally diagnosed congenital heart disease.

    Science.gov (United States)

    Mawson, Isabel E; Babu, Pratusha L; Simpson, John M; Fox, Grenville F

    2018-05-01

    A retrospective review of admission preductal oxygen saturations of neonates with antenatally diagnosed critical congenital heart disease (CCHD) was performed to investigate the differences in newborn pulse oximetry (Pulsox) by specific CCHD diagnosis. Saturations were recorded at median of  34 weeks and birth weight > 1.8 kg. A statistically significant increase in the proportion with low admission saturations was seen using ≤ 95% saturation threshold (72% (95% CI 66-78)) compared to ≤ 92% (52% (95% CI 46-59)) and ≤ 90% (46% (95% CI 39-52)). Sub-group analysis found the proportion of neonates with low saturations varied according to the specific CCHD diagnosis with only 20-42% of neonates with aortic stenosis, coarctation of the aorta and pulmonary stenosis having saturations ≤ 95%. The proportion of neonates with low admission oxygen saturation varied by CCHD diagnosis with those without critically reduced pulmonary blood flow not having low admission saturations, in general, even using the ≤ 95% threshold which had the highest proportions of abnormal saturations. This data may assist developing Pulsox screening policies. What is Known: • The addition of pulse oximetry (Pulsox) screening to the routine newborn examination increases the sensitivity of CCHD detection. Pulsox screening is also highly specific for CCHD in asymptomatic neonates, with low false-positive rates. • Early diagnosis of CCHD improves patient outcomes in relation to both morbidity and mortality. What is New: • The proportion of affected infants with an abnormal Pulsox result varies by CCHD diagnosis and screening threshold. In our study using the ≤ 95% threshold gave the highest proportion of neonates with abnormal saturations at admission. • In general, Pulsox yield of abnormal results is low for CCHD diagnoses not associated with critically reduced pulmonary blood flow; however, increasing the Pulsox threshold increased the proportion of infants with an

  20. Detection of cerebral arterial gas embolism using regional cerebral oxygen saturation, quantitative electroencephalography, and brain oxygen tension in the swine

    NARCIS (Netherlands)

    Weenink, R. P.; Hollmann, M. W.; Stevens, M. F.; Kager, J.; van Gulik, T. M.; van Hulst, R. A.

    2014-01-01

    Cerebral air emboli occur as a complication of invasive medical procedures. The sensitivity of cerebral monitoring methods for the detection of air emboli is not known. This study investigates the utility of electroencephalography and non-invasively measured cerebral oxygen saturation in the

  1. Tissue oximetry: a comparison of mean values of regional tissue saturation, reproducibility and dynamic range of four NIRS-instruments on the human forearm

    DEFF Research Database (Denmark)

    Hyttel-Sørensen, Simon; Sorensen, Line C; Riera, Joan

    2011-01-01

    We compared absolute values of regional tissue hemoglobin saturation (StO(2)), reproducibility, and dynamic range of four different instruments on the forearm of adults. The sensors were repositioned 10 times on each subject. Dynamic range was estimated by exercise with subsequent arterial occlus...

  2. Sodium addition and/or oxygen saturation of iohexol during normal and reduced perfusion pressure

    International Nuclear Information System (INIS)

    Baath, L.

    1990-01-01

    The influence on contractile force (CF) and the propensity for ventricular fibrillation (VF) from infusing the non-ionic contrast medium iohexol during normal (75 cm H 2 O) and reduced perfusion pressure (35 cm H 2 O) were investigated in the isolated rabbit heart. Both during normal and reduced perfusion pressure iohexol (150 mg I/ml) with oxygen saturation caused a smaller reduction of CF than iohexol without oxygen. During reduced pressure iohexol with sodium addition (28 mM NaCl) caused less depression of CF than iohexol without sodium. The combination of sodium addition and oxygen saturation had the least influence on CF. Iohexol (350 mg I/ml) without sodium had a similar fibrillatory propensity during both normal and reduced pressure. Enriching iohexol with 28 mM NaCl decreased the risk of VF. The decrease was similar during both normal and reduced pressure. The risk of VF from oxygen saturation of iohexol (350 mg I/ml, without sodium) was similar during both normal and reduced pressure. It is concluded that a small addition of sodium and/or oxygen saturation of a non-ionic monomeric contrast medium have beneficial effects on the heart both during normal perfusion pressure and during ischemia. (orig.)

  3. Cerebral near infrared spectroscopy oximetry in extremely preterm infants

    DEFF Research Database (Denmark)

    Hyttel-Sorensen, Simon; Pellicer, Adelina; Alderliesten, Thomas

    2015-01-01

    OBJECTIVE: To determine if it is possible to stabilise the cerebral oxygenation of extremely preterm infants monitored by cerebral near infrared spectroscopy (NIRS) oximetry. DESIGN: Phase II randomised, single blinded, parallel clinical trial. SETTING: Eight tertiary neonatal intensive care unit...

  4. Changes in retinal oxygen saturation after intravitreal aflibercept in patients with diabetic macular edema

    DEFF Research Database (Denmark)

    Blindbæk, Søren Leer; Peto, Tunde; Grauslund, Jakob

    2017-01-01

    Design of study: Three months prospective interventional study. Purpose: To evaluate changes in retinal arterial and venous oxygen saturation after intravitreal aflibercept in patients with diabetic macular edema (DME). Methods: We included 17 patients with DME, central retinal thickness (CRT) >300...

  5. In vivo EPR oximetry using an isotopically-substituted nitroxide: Potential for quantitative measurement of tissue oxygen

    Science.gov (United States)

    Weaver, John; Burks, Scott R.; Liu, Ke Jian; Kao, Joseph P.Y.; Rosen, Gerald M.

    2017-01-01

    Variations in brain oxygen (O2) concentration can have profound effects on brain physiology. Thus, the ability to quantitate local O2 concentrations noninvasively in vivo could significantly enhance understanding of several brain pathologies. However, quantitative O2 mapping in the brain has proven difficult. The electron paramagnetic resonance (EPR) spectra of nitroxides are sensitive to molecular O2 and can be used to estimate O2 concentrations in aqueous media. We recently synthesized labile-ester-containing nitroxides, such as 3-acetoxymethoxycarbonyl-2,2,5,5-tetramethyl-1-pyrrolidinyloxyl (nitroxide 4), which accumulate in cerebral tissue after in situ hydrolysis, and thus enable spatial mapping of O2 concentrations in the mouse brain by EPR imaging. In an effort to improve O2 quantitation, we prepared 3-acetoxymethox ycarbonyl-2,2,5,5-tetra(2H3)methyl-1-(3,4,4-2H3,1-15N)pyrrolidinyloxyl (nitroxide 2), which proved to be a more sensitive probe than its normo-isotopic version for quantifying O2 in aqueous solutions of various O2 concentrations. We now demonstrate that this isotopically substituted nitroxide is ~2-fold more sensitive in vivo than the normo-isotopic nitroxide 4. Moreover, in vitro and in vivo EPR spectral-spatial imaging results with nitroxide 2 demonstrate significant improvement in resolution, reconstruction and spectral response to local O2 concentrations in cerebral tissue. Thus, isotopic-substituted nitroxides, such as 2, are excellent sensors for in vivo O2 quantitation in tissues, such as the brain. PMID:27567323

  6. Oxygen diffusion-concentration in phospholipidic model membranes. An ESR-saturation study

    International Nuclear Information System (INIS)

    Vachon, A.; Lecomte, C.; Berleur, F.

    1986-04-01

    Fully hydrated liposomes of dipalmitoyl-phosphatidylcholine were labelled with 5 (or 7, 10, 12, 16)-doxyl stearic acid at pH 6 and 8, and studied by the continuous wave ESR-saturation technique. The ESR spectral magnitude depends on the hyperfrequency power P and on both T 1 and T 2 relaxation times. Saturation, i.e. the non linearity of the spectral magnitude plotted versus √P can be quantified by a P1/2 parameter (power at which the signal is half as great as it would be without saturation). If we assume T 2 weakly modified by spin exchange between paramagnetic spin probe and oxygen in triplet state, P1/2 is inversely proportional to T 1 , and becomes a sensitive parameter to appreciate the oxygen transport (oxygen diffusion-concentration product) inside the bilayers. According to the DPPC bilayer phase transition diagrams, P1/2 (oxygen diffusion-concentration) is related to the thermodynamic state of the membrane. This technique provides further informations on a particular property of a radioprotective agent, cysteamine, which seems to inhibit spin-triplet exchange and hence maximizes T 1 (minimizes P1/2). Since radioprotective agents are known to act by scavenging radiation-induced free radicals and by inhibiting oxygen-dependent free radical processes, such a result may contribute to elucidate radioprotecting mechanisms

  7. Validation of the Nonin 8600V Pulse Oximeter for heart rate and oxygen saturation measurements in rats.

    Science.gov (United States)

    Bernard, Susan L; An, Dowon; Glenny, Robb W

    2004-05-01

    This report validates the use and limitations of the Nonin Pulse Oximeter for measuring heart rate and oxygen saturation in rats. Eight anesthetized Sprague-Dawley rats were intubated and catheterized. Oxygen saturation was directly measured from arterial blood by using a Radiometer OSM3 Hemoximeter adjusted for rat blood as well as indirectly by using the Nonin Pulse Oximeter. Oxygen saturation was changed by varying the level of inhaled oxygen. Heart rate was measured in two ways: 1) by using the signal from the Nonin Pulse Oximeter and 2) by counting the pressure pulses from the transduced blood pressure. There was excellent agreement between heart rate values measured by the Nonin Pulse Oximeter and that measured by counting the pulses from the arterial blood pressure recording. The Nonin Pulse Oximeter underestimated oxygen saturations by about 3% to 5% compared to the Hemoximeter. Overall, the pulse oximeter reflected important trends in oxygen saturations, making it a useful tool for laboratory animal medicine.

  8. A technique for measuring oxygen saturation in biological tissues based on diffuse optical spectroscopy

    Science.gov (United States)

    Kleshnin, Mikhail; Orlova, Anna; Kirillin, Mikhail; Golubiatnikov, German; Turchin, Ilya

    2017-07-01

    A new approach to optical measuring blood oxygen saturation was developed and implemented. This technique is based on an original three-stage algorithm for reconstructing the relative concentration of biological chromophores (hemoglobin, water, lipids) from the measured spectra of diffusely scattered light at different distances from the probing radiation source. The numerical experiments and approbation of the proposed technique on a biological phantom have shown the high reconstruction accuracy and the possibility of correct calculation of hemoglobin oxygenation in the presence of additive noise and calibration errors. The obtained results of animal studies have agreed with the previously published results of other research groups and demonstrated the possibility to apply the developed technique to monitor oxygen saturation in tumor tissue.

  9. Relationship Between Cerebral Oxygenation and Hemodynamic and Oxygen Transport Parameters in Surgery for Acquired Heart Diseases

    Directory of Open Access Journals (Sweden)

    A. I. Lenkin

    2012-01-01

    Full Text Available Objective: to evaluate the relationship between cerebral oxygenation and hemodynamic and oxygen transport parameters in surgical correction of concomitant acquired heart diseases. Subjects and methods. Informed consent was received from 40 patients who required surgery because of concomitant (two or more acquired heart defects. During procedure, perioperative monitoring of oxygen transport and cerebral oxygenation was performed with the aid of PiCCO2 monitor (Pulsion Medical Systems, Germany and a Fore-Sight cerebral oximeter (CASMED, USA. Anesthesia was maintained with propofol and fen-tanyl, by monitoring the depth of anesthesia. Early postoperative intensive therapy was based on the protocol for early targeted correction of hemodynamic disorders. Oxygen transport and cerebral oxygenation parameters were estimated intraopera-tively and within 24 postoperative hours. A statistical analysis including evaluation of Spearman correlations was performed with the aid of SPSS 15.0. Results. During perfusion, there was a relationship between cerebral oximetry values and hemat-ocrit levels, and oxygen partial pressure in the venous blood. Furthermore, a negative correlation between cerebral oximetry values and blood lactate levels was found 30 minutes after initiation of extracorporeal circulation (EC. During the study, there was a positive correlation between cerebral oxygenation and values of cardiac index, central venous saturation, and oxygen delivery index. There was a negative relationship between cerebral oxygenation and extravascular lung water at the beginning of surgery and a correlation between cerebral oximetry values and oxygenation index by the end of the first 24 postoperative hours. Conclusion. The cerebral oxygenation values correlate -with the main determinants of oxygen transport during EC and after cardiac surgical procedures. Cerebral oximetry may be used in early targeted therapy for the surgical correction of acquired combined

  10. New laser system for highly sensitive clinical pulse oximetry

    Science.gov (United States)

    Hamza, Mostafa; Hamza, Mohammad

    1996-04-01

    This paper describes the theory and design of a new pulse oximeter in which laser diodes and other compact laser sources are used for the measurement of oxygen saturation in patients who are at risk of developing hypoxemia. The technique depends upon illuminating special sites of the skin of the patient with radiation from modulated laser sources at selected wavelengths. The specific laser wavelengths are chosen based on the absorption characteristics of oxyhemoglobin, reduced hemoglobin and other interfering sources for obtaining more accurate measurements. The laser radiation transmitted through the tissue is detected and signal processing based on differential absorption laser spectroscopy is done in such a way to overcome the primary performance limitations of the conventionally used pulse oximetry. The new laser pulse oximeter can detect weak signals and is not affected by other light sources such as surgical lamps, phototherapy units, etc. The detailed description and operating characteristics of this system are presented.

  11. Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.

    Science.gov (United States)

    Shafique, M; Kyriacou, P A; Pal, S K

    2012-06-01

    Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values (SpO₂). In poorly perfused tissues, SpO₂ readings may be compromised due to the poor quality of the PPG signals. A multimode finger PPG probe that operates simultaneously in reflectance, transmittance and a combined mode called "transreflectance" was developed, in an effort to improve the quality of the PPG signals in states of hypoperfusion. Experiments on 20 volunteers were conducted to evaluate the performance of the multimode PPG sensor and compare the results with a commercial transmittance pulse oximeter. A brachial blood pressure cuff was used to induce artificial hypoperfusion. Results showed that the amplitude of the transreflectance AC PPG signals were significantly different (p signals obtained from the other two conventional PPG sensors (reflectance and transmittance). At induced brachial pressures between 90 and 135 mmHg, the reflectance finger pulse oximeter failed 25 times (failure rate 42.2 %) to estimate SpO₂ values, whereas the transmittance pulse oximeter failed 8 times (failure rate 15.5 %). The transreflectance pulse oximeter failed only 3 times (failure rate 6.8 %) and the commercial pulse oximeter failed 17 times (failure rate 29.4 %).

  12. Optimization measurement of muscle oxygen saturation under isometric studies using FNIRS

    Science.gov (United States)

    Halim, A. A. A.; Laili, M. H.; Salikin, M. S.; Rusop, M.

    2018-05-01

    Development of functional near infrared spectroscopy (fNIRS) technologies has advanced quantification signal using multiple wavelength and detector to investigate hemodynamic response in human muscle. These non-invasive technologies have been widely used to solve the propagation of light inside the tissues including the absorption, scattering coefficient and to quantify the oxygenation level of haemoglobin and myoglobin in human muscle. The goal of this paper is to optimize the measurement of muscle oxygen saturation during isometric exercise using functional near infrared spectroscopy (fNIRS). The experiment was carried out on 15 sedentary healthy male volunteers. All volunteers are required to perform an isometric exercise at three assessment of muscular fatigue's level on flexor digitalis (FDS) muscle in the human forearm using fNIRS. The slopes of the signals have been highlighted to evaluate the muscle oxygen saturation of regional muscle fatigue. As a result, oxygen saturation slope from 10% exercise showed steeper than the first assessment at 30%-50% of fatigues level. The hemodynamic signal response showed significant value (p=0.04) at all three assessment of muscular fatigue's level which produce a p-value (p<0.05) measured by fNIRS. Thus, this highlighted parameter could be used to estimate fatigue's level of human and could open other possibilities to study muscle performance diagnosis.

  13. Optimal spacing between transmitting and receiving optical fibres in reflectance pulse oximetry

    Energy Technology Data Exchange (ETDEWEB)

    Hickey, M; Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, Northampton Square, London, EC1V 0HB (United Kingdom)

    2007-10-15

    Splanchnic ischaemia can ultimately lead to cellular hypoxia and necrosis, and may well contribute to the development of multiple organ failures and increased mortality. Therefore, it is of utmost importance to monitor abdominal organ blood oxygen saturation (SpO{sub 2}). Pulse oximetry has been widely accepted as a reliable method for monitoring oxygen saturation of arterial blood. Animal studies have also shown it to be effective in the monitoring of blood oxygen saturation in the splanchnic region. However, commercially available pulse oximeter probes are not suitable for the continuous assessment of SpO{sub 2} in the splanchnic region. Therefore, there is a need for a new sensor technology that will allow the continuous measurement of SpO{sub 2} in the splanchnic area pre-operatively, operatively and post-operatively. For this purpose, a new fibre optic sensor and processing system utilising the principle of reflectance pulse oximetry has been developed. The accuracy in the estimation of SpO{sub 2} in pulse oximetry depends on the quality and amplitude of the photoplethysmographic (PPG) signal and for this reason an experimental procedure was carried out to examine the effect of the source-detector separation distance on the acquired PPG signals, and to ultimately select an optimal separation for the final design of the fibre-optic probe. PPG signals were obtained from the finger for different separation distances between the emitting and detecting fibres. Good quality PPG signals with large amplitudes and high signal-to-noise ratio were detected in the range of 3mm to 6mm. At separation distances between 1mm and 2mm, PPG signals were erratic with no resemblance to a conventional PPG signal. At separation distances greater than 6mm, the amplitudes of PPG signals were very small and not appropriate for processing. This investigation indicates the suitability of optical fibres as a new pulse oximetry sensor for estimating blood oxygen saturation (SpO{sub 2}) in

  14. Oxygen breathing accelerates decompression from saturation at 40 msw in 70-kg swine.

    Science.gov (United States)

    Petersen, Kyle; Soutiere, Shawn E; Tucker, Kathryn E; Dainer, Hugh M; Mahon, Richard T

    2010-07-01

    Submarine disaster survivors can be transferred from a disabled submarine at a pressure of 40 meters of seawater (msw) to a new rescue vehicle; however, they face an inherently risky surface interval before recompression and an enormous decompression obligation due to a high likelihood of saturation. The goal was to design a safe decompression protocol using oxygen breathing and a trial-and-error methodology. We hypothesized that depth, timing, and duration of oxygen breathing during decompression from saturation play a role to mitigate decompression outcomes. Yorkshire swine (67-75 kg), compressed to 40 msw for 22 h, underwent one of three accelerated decompression profiles: (1) 13.3 h staged air decompression to 18 msw, followed by 1 h oxygen breathing, then dropout; (2) direct decompression to 18 msw followed by 1 h oxygen breathing then dropout; and (3) 1 h oxygen prebreathe at 40 msw followed by 1 h mixed gas breathing at 26 msw, 1 h oxygen breathing at 18 msw, and 1 h ascent breathing oxygen. Animals underwent 2-h observation for signs of DCS. Profile 1 (14.3 h total) resulted in no deaths, no Type II DCS, and 20% Type I DCS. Profile 2 (2.1 h total) resulted in 13% death, 50% Type II DCS, and 75% Type I DCS. Profile 3 (4.5 h total) resulted in 14% death, 21% Type II DCS, and 57% Type I DCS. No oxygen associated seizures occurred. Profile 1 performed best, shortening decompression with no death or severe DCS, yet it may still exceed emergency operational utility in an actual submarine rescue.

  15. Photoirradiation system with depth optical dosimetry control in initial oxygen saturation measurement

    International Nuclear Information System (INIS)

    Quintanar, L.; Stolik, S.; Rosa, J. de la; Moreno, E.

    2012-01-01

    Photodynamic Therapy is a technique in which a photosensitizing substance is applied that is activated by light and it generates reactive oxygen species which cause selective cell destruction. The efficiency of the therapy is affected by the parameters dose. In this work it is shown a photo-irradiation system for superficial Photodynamic Therapy, using as a light source a light emitting diode with an automatic control of optical power based on a model of the distribution of light in depth that was tested in tissue phantoms. It also has a reflective pulse oximeter for the measurement of the initial oxygen saturation. (Author)

  16. Degradation of phospholipids under different types of irradiation and varying oxygen saturation

    Czech Academy of Sciences Publication Activity Database

    Vyšín, Luděk; Tomanová, K.; Pavelková, T.; Wagner, Richard; Davídková, Marie; Múčka, V.; Čuba, V.; Juha, Libor

    2017-01-01

    Roč. 56, č. 3 (2017), s. 241-247 ISSN 0301-634X R&D Projects: GA ČR GA13-28721S; GA ČR(CZ) GBP108/12/G108; GA MŠk LM2015056 Institutional support: RVO:68378271 ; RVO:61389005 Keywords : lipid peroxidation * DOPC * gamma rays * eectrons * protons * oxygen saturation Subject RIV: BO - Biophysics OBOR OECD: Biophysics Impact factor: 2.398, year: 2016

  17. Cerebral oxygen saturation and cardiac output during anaesthesia in sitting position for neurosurgical procedures: a prospective observational study.

    Science.gov (United States)

    Schramm, P; Tzanova, I; Hagen, F; Berres, M; Closhen, D; Pestel, G; Engelhard, K

    2016-10-01

    Neurosurgical operations in the dorsal cranium often require the patient to be positioned in a sitting position. This can be associated with decreased cardiac output and cerebral hypoperfusion, and possibly, inadequate cerebral oxygenation. In the present study, cerebral oxygen saturation was measured during neurosurgery in the sitting position and correlated with cardiac output. Perioperative cerebral oxygen saturation was measured continuously with two different monitors, INVOS ® and FORE-SIGHT ® . Cardiac output was measured at eight predefined time points using transoesophageal echocardiography. Forty patients were enrolled, but only 35 (20 female) were eventually operated on in the sitting position. At the first time point, the regional cerebral oxygen saturation measured with INVOS ® was 70 (sd 9)%; thereafter, it increased by 0.0187% min -1 (P<0.01). The cerebral tissue oxygen saturation measured with FORE-SIGHT ® started at 68 (sd 13)% and increased by 0.0142% min -1 (P<0.01). The mean arterial blood pressure did not change. Cardiac output was between 6.3 (sd 1.3) and 7.2 (1.8) litre min -1 at the predefined time points. Cardiac output, but not mean arterial blood pressure, showed a positive and significant correlation with cerebral oxygen saturation. During neurosurgery in the sitting position, the cerebral oxygen saturation slowly increases and, therefore, this position seems to be safe with regard to cerebral oxygen saturation. Cerebral oxygen saturation is stable because of constant CO and MAP, while the influence of CO on cerebral oxygen saturation seems to be more relevant. NCT01275898. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Monitoring mixed venous oxygen saturation in patients with obstructive shock after massive pulmonary embolism.

    Science.gov (United States)

    Krivec, Bojan; Voga, Gorazd; Podbregar, Matej

    2004-05-31

    Patients with massive pulmonary embolism and obstructive shock usually require hemodynamic stabilization and thrombolysis. Little is known about the optimal and proper use of volume infusion and vasoactive drugs, or about the titration of thrombolytic agents in patients with relative contraindication for such treatment. The aim of the study was to find the most rapidly changing hemodynamic variable to monitor and optimize the treatment of patients with obstructive shock following massive pulmonary embolism. Ten consecutive patients hospitalized in the medical intensive care unit in the community General Hospital with obstructive shock following massive pulmonary embolism were included in the prospective observational study. Heart rate, systolic arterial pressure, central venous pressure, mean pulmonary-artery pressure, cardiac index, total pulmonary vascular-resistance index, mixed venous oxygen saturation, and urine output were measured on admission and at 1, 2, 3, 4, 8, 12, and 16 hours. Patients were treated with urokinase through the distal port of a pulmonary-artery catheter. At 1 hour, mixed venous oxygen saturation, systolic arterial pressure and cardiac index were higher than their admission values (31+/-10 vs. 49+/-12%, p<0.0001; 86+/-12 vs. 105+/-17 mmHg, p<0.01; 1.5+/-0.4 vs. 1.9+/-0.7 L/min/m2, p<0.05; respectively), whereas heart rate, central venous pressure, mean pulmonary-artery pressure and urine output remained unchanged. Total pulmonary vascular-resistance index was lower than at admission (29+/-10 vs. 21+/-12 mmHg/L/min/m2, p<0.05). The relative change of mixed venous oxygen saturation at hour 1 was higher than the relative changes of all other studied variables (p<0.05). Serum lactate on admission and at 12 hours correlated to mixed venous oxygen saturation (r=-0.855, p<0.001). In obstructive shock after massive pulmonary embolism, mixed venous oxygen saturation changes more rapidly than other standard hemodynamic variables.

  19. TH-AB-209-05: Validating Hemoglobin Saturation and Dissolved Oxygen in Tumors Using Photoacoustic Computed Tomographic Spectroscopic Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, J; Sick, J; Liu, B [Purdue University, West Lafayette, IN (United States); Cao, N [University of Washington Medical Center, Seattle, WA (United States); Nakshatri, H; Mendonca, M [Indiana University - Purdue University Indianapolis, Indianapolis, IN (United States); Stantz, K [Purdue University, West Lafayette, IN (United States); Indiana University - Purdue University Indianapolis, Indianapolis, IN (United States)

    2016-06-15

    Purpose: Photoacoustic computed tomographic spectroscopy (PCT-S) provides intra-tumor measurements of oxygenation with high spatial resolution (0.2mm) and temporal fidelity (1–2 minutes) without the need for exogenous agents or ionizing radiation, thus providing a unique in vivo assay to measure SaO{sub 2} and investigate acute and chronic forms of hypoxia. The goal of this study is to validate in vivo SaO{sub 2} levels within tail artery of mice and the relationship between SaO{sub 2} and pO{sub 2} within subcutaneous breast tumors using PCT-S imaging, pulse oximetry and an OxyLite probe. Methods: A closed circuit phantom was fabricated to control blood oxygenation levels, where SaO{sub 2} was measured using a co-oximeter and pO{sub 2} using an Oxylite probe. Next, SaO{sub 2} levels within the tail arteries of mice (n=3) were measured using PCT-S and pulse oximetry while breathing high-to-low oxygen levels (6-cycles). Finally, PCT-S was used to measure SaO{sub 2} levels in MCF-7, MCF-7-VEGF165, and MDA-MB-231 xenograft breast tumors and compared to Oxylite pO{sub 2} levels values. Results: SaO{sub 2} and pO{sub 2} data obtained from the calibration phantom was fit to Hill’s equation: aO{sub 2} levels between 88 and 52% demonstrated a linear relationship (r2=0.96) and a 3.2% uncertainty between PCT-S values relative to pulse oximetry. Scatter plots of localized PCT-S measured SaO2 and Oxylite pO{sub 2} levels in MCF-7/MCF-7-VEGF165 and MDA-MD-231 breast tumors were fit to Hill’s equation: P50=17.2 and 20.7mmHg, and n=1.76 and 1.63. These results are consistent with sigmoidal form of Hill’s equation, where the lower P{sub 50} value is indicative of an acidic tumor microenvironment. Conclusion: The results demonstrate photoacoustic imaging can be used to measure SaO{sub 2} cycling and intra-tumor oxygenation, and provides a powerful in vivo assay to investigate the role of hypoxia in radiation, anti-angiogenic, and immunotherapies.

  20. First day of life pulse oximetry screening to detect congenital heart defects.

    Science.gov (United States)

    Meberg, Alf; Brügmann-Pieper, Sabine; Due, Reidar; Eskedal, Leif; Fagerli, Ingebjørg; Farstad, Teresa; Frøisland, Dag Helge; Sannes, Catharina Hovland; Johansen, Ole Jakob; Keljalic, Jasmina; Markestad, Trond; Nygaard, Egil Andre; Røsvik, Alet; Silberg, Inger Elisabeth

    2008-06-01

    To evaluate the efficacy of first day of life pulse oximetry screening to detect congenital heart defects (CHDs). We performed a population-based prospective multicenter study of postductal (foot) arterial oxygen saturation (SpO(2)) in apparently healthy newborns after transfer from the delivery suite to the nursery. SpO(2) < 95% led to further diagnostic evaluations. Of 57,959 live births, 50,008 (86%) were screened. In the screened population, 35 CHDs were [corrected] classified as critical (ductus dependent, cyanotic). CHDs were prospectively registered and diagnosed in 658/57,959 (1.1%) [corrected] Of the infants screened, 324 (0.6%) failed the test. Of these, 43 (13%) had CHDs (27 critical), and 134 (41%) had pulmonary diseases or other disorders. The remaining 147 infants (45%) were healthy with transitional circulation. The median age for babies with CHDs at failing the test was 6 hours (range, 1-21 hours). For identifying critical CHDs, the pulse oximetry screening had a sensitivity rate of 77.1% (95% CI, 59.4-89.0), specificity rate of 99.4% (95% CI, 99.3-99.5), and a false-positive rate of 0.6% (95% CI, 0.5-0.7). Early pulse oximetry screening promotes early detection of critical CHDs and other potentially severe diseases. The sensitivity rate for detecting critical CHDs is high, and the false-positive rate is low.

  1. An Electronic Patch for wearable health monitoring by reflectance pulse oximetry.

    Science.gov (United States)

    Haahr, Rasmus G; Duun, Sune B; Toft, Mette H; Belhage, Bo; Larsen, Jan; Birkelund, Karen; Thomsen, Erik V

    2012-02-01

    We report the development of an Electronic Patch for wearable health monitoring. The Electronic Patch is a new health monitoring system incorporating biomedical sensors, microelectronics, radio frequency (RF) communication, and a battery embedded in a 3-dimensional hydrocolloid polymer. In this paper the Electronic Patch is demonstrated with a new optical biomedical sensor for reflectance pulse oximetry so that the Electronic Patch in this case can measure the pulse and the oxygen saturation. The reflectance pulse oximetry solution is based on a recently developed annular backside silicon photodiode to enable low power consumption by the light emitting components. The Electronic Patch has a disposable part of soft adhesive hydrocolloid polymer and a reusable part of hard polylaurinlactam. The disposable part contains the battery. The reusable part contains the reflectance pulse oximetry sensor and microelectronics. The reusable part is 'clicked' into the disposable part when the patch is prepared for use. The patch has a size of 88 mm by 60 mm and a thickness of 5 mm.

  2. [Near-infrared spectroscopy in sepsis therapy : predictor of a low central venous oxygen saturation].

    Science.gov (United States)

    Lichtenstern, C; Koch, C; Röhrig, R; Rosengarten, B; Henrich, M; Weigand, M A

    2012-10-01

    Early goal-directed hemodynamic optimization has become a cornerstone of sepsis therapy. One major defined goal is to achieve adequate central venous oxygen saturation (SO(2)). This study aimed to investigate the correlation between central venous SO(2) and frontal cerebral near-infrared spectroscopy (NIRS) measurement in patients with severe sepsis and septic shock. The NIRS method provides non-invasive measurement of regional oxygen saturation (rSO(2)) in tissues approximately 2 cm below the optical NIRS sensors which depends on arterial, capillary and venous blood. Thus this system gives site-specific real-time data about the balance of oxygen supply and demand. This was a secondary analysis from a prospective study of surgical intensive care (ICU) patients in the early phase of severe sepsis or septic shock. Bilateral cerebral rSO(2), central venous SO(2), arterial oxygen saturation (S(a)O(2)) and other surrogate parameters of oxygen supply, such as hemoglobin, partial pressure of oxygen and oxygen content in arterial blood were recorded. A total of 16 ICU patients (4 women, median age 65.5 years) were included in the study. As sepsis focus an intra-abdominal infection was detected in 62.5 % of patients, severe pneumonia was determined in 31.3 % and skin and soft tissue infections were recognized in 12.5 %. At study inclusion 50 % of patients had septic shock, the median sequential organ failure assessment (SOFA) score was 10.2 (interquartile range 5.25-8.75) and the median acute physiology and chronic health evaluation II (APACHE II) score was 26 (range 23.25-29.75). Mortality at day 28 was 37.5 %. Minimum rSO(2) (median 58) and right-sided rSO(2) (median 58) values showed a significant correlation in the analysis of receiver operating characteristics (area under the curve 0.844, p= 0.045). A central venous SO(2)< 70 % was indicated by rSO(2)< 56.5 with sensitivity and specificity of 75 % and 100 %, respectively. Cerebral NIRS could provide a fast and easily

  3. Mental abilities and performance efficacy under a simulated 480 meters helium-oxygen saturation diving

    Directory of Open Access Journals (Sweden)

    gonglin ehou

    2015-07-01

    Full Text Available Stress in extreme environment severely disrupts human physiology and mental abilities. The present study investigated the cognition and performance efficacy of four divers during a simulated 480 meters helium-oxygen saturation diving. We analyzed the spatial memory, 2D/3D mental rotation functioning, grip strength, and hand-eye coordination ability in four divers during the 0 – 480 meters compression and decompression processes of the simulated diving. The results showed that except for its mild decrease on grip strength, the high atmosphere pressure condition significantly impaired the hand-eye coordination (especially at 300 meters, the reaction time and correct rate of mental rotation, as well as the spatial memory (especially as 410 meters, showing high individual variability. We conclude that the human cognition and performance efficacy are significantly affected during deep water saturation diving.

  4. [The source and factors that influence tracheal pulse oximetry signal].

    Science.gov (United States)

    Fan, Xiao-hua; Wei, Wei; Wang, Jian; Mu, Ling; Wang, Li

    2010-03-01

    To investigate the source and factors that influence tracheal pulse oximetry signal. The adult mongrel dog was intubated after anesthesia. The tracheal tube was modified by attaching a disposable pediatric pulse oximeter to the cuff. The chest of the dog was cut open and a red light from the tracheal oximeter was aligned with the deeper artery. The changes in tracheal pulse oxygen saturation (SptO2) signal were observed after the deeper artery was blocked temporarily. The photoplethysmography (PPG) and readings were recorded at different intracuff pressures. The influence of mechanical ventilation on the signal was also tested and compared with pulse oxygen saturation (SpO2). The SptO2 signal disappeared after deeper artery was blocked. The SptO2 signal changed with different intracuff pressures (P signal appeared under 20-60 cm H2O of intracuff pressure than under 0-10 cm H2O of intracuff pressure(P signal under a condition with mechanical ventilation differed from that without mechanical ventilation (P signal is primarily derived from deeper arteries around the trachea, not from the tracheal wall. Both intracuff pressures and mechanical ventilation can influence SptO2 signal. The SptO2 signal under 20-60 cm H2O of intracuff pressure is stronger than that under 0-10 em H2O of intracuff pressure. Mechanical ventilation mainly changes PPG.

  5. [Design of Oxygen Saturation, Heart Rate, Respiration Rate Detection System Based on Smartphone of Android Operating System].

    Science.gov (United States)

    Zhu, Mingshan; Zeng, Bixin

    2015-03-01

    In this paper, we designed an oxygen saturation, heart rate, respiration rate monitoring system based on smartphone of android operating system, physiological signal acquired by MSP430 microcontroller and transmitted by Bluetooth module.

  6. An efficient optimization method to improve the measuring accuracy of oxygen saturation by using triangular wave optical signal

    Science.gov (United States)

    Li, Gang; Yu, Yue; Zhang, Cui; Lin, Ling

    2017-09-01

    The oxygen saturation is one of the important parameters to evaluate human health. This paper presents an efficient optimization method that can improve the accuracy of oxygen saturation measurement, which employs an optical frequency division triangular wave signal as the excitation signal to obtain dynamic spectrum and calculate oxygen saturation. In comparison to the traditional method measured RMSE (root mean square error) of SpO2 which is 0.1705, this proposed method significantly reduced the measured RMSE which is 0.0965. It is notable that the accuracy of oxygen saturation measurement has been improved significantly. The method can simplify the circuit and bring down the demand of elements. Furthermore, it has a great reference value on improving the signal to noise ratio of other physiological signals.

  7. Principle study on the signal connection at transabdominal fetal pulse oximetry

    Directory of Open Access Journals (Sweden)

    Böttrich Marcel

    2016-09-01

    Full Text Available Transabdominal fetal pulse oximetry is an approach to measure oxygen saturation of the unborn child non-invasively. The principle of pulse oximetry is applied to the abdomen of a pregnant woman, such that the measured signal includes both, the maternal and the fetal pulse curve. One of the major challenges is to extract the shape of the fetal pulse curve from the mixed signal for computation of the oxygen saturation. In this paper we analyze the principle kind of connection of the fetal and maternal pulse curves in the measured signal. A time varying finite element model is used to rebuild the basic measurement environment, including a bulk tissue and two independently pulsing arteries to model the fetal and maternal blood circuit. The distribution of the light fluence rate in the model is computed by applying diffusion equation. From the detectors we extracted the time dependent fluence rate and analyzed the signal regarding its components. The frequency spectra of the signals show peaks at the fetal and maternal basic frequencies. Additional signal components are visible in the spectra, indicating multiplicative coupling of the fetal and maternal pulse curves. We conclude that the underlying signal model of algorithms for robust extraction of the shape of the fetal pulse curve, have to consider additive and multiplicative signal coupling.

  8. The Feasibility and Validity of a Remote Pulse Oximetry System for Pulmonary Rehabilitation: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Jonathan Tang

    2012-01-01

    Full Text Available Pulmonary rehabilitation is an effective treatment for people with chronic obstructive pulmonary disease. However, access to these services is limited especially in rural and remote areas. Telerehabilitation has the potential to deliver pulmonary rehabilitation programs to these communities. The aim of this study was threefold: to establish the technical feasibility of transmitting real-time pulse oximetry data, determine the validity of remote measurements compared to conventional face-to-face measures, and evaluate the participants’ perception of the usability of the technology. Thirty-seven healthy individuals participated in a single remote pulmonary rehabilitation exercise session, conducted using the eHAB telerehabilitation system. Validity was assessed by comparing the participant's oxygen saturation and heart rate with the data set received at the therapist’s remote location. There was an 80% exact agreement between participant and therapist data sets. The mean absolute difference and Bland and Altman’s limits of agreement fell within the minimum clinically important difference for both oxygen saturation and heart rate values. Participants found the system easy to use and felt confident that they would be able to use it at home. Remote measurement of pulse oximetry data for a pulmonary rehabilitation exercise session was feasible and valid when compared to conventional face-to-face methods.

  9. The effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing total knee replacement surgery

    OpenAIRE

    Song, Inkyung; Kim, Dong Yeon; Kim, Youn Jin

    2012-01-01

    Background Inflation and deflation of a pneumatic tourniquet used in total knee replacement surgery induces various changes in patient's hemodynamic and metabolic status, which may result in serious complications, especially in aged patients. Near-infrared spectroscopy (NIRS) is a monitoring device designed to estimate the regional cerebral oxygen saturation. We evaluated the effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing tot...

  10. Changes in retinal venular oxygen saturation predict activity of proliferative diabetic retinopathy 3 months after panretinal photocoagulation

    DEFF Research Database (Denmark)

    Torp, Thomas Lee; Kawasaki, Ryo; Wong, Tien Yin

    2018-01-01

    .4 to -1.4), focal: -4.5% (95% CI -12.1 to 3.2)). In a multiple logistic regression model, increment in global retinal venular oxygen saturation (OR 1.30 per 1%-point increment, p=0.017) and decrement in AV oxygen saturation difference (OR 0.72 per 1%-point increment, p=0.016) at 3M independently predicted...

  11. Neural networks and wavelet analysis in the computer interpretation of pulse oximetry data

    Energy Technology Data Exchange (ETDEWEB)

    Dowla, F.U.; Skokowski, P.G.; Leach, R.R. Jr.

    1996-03-01

    Pulse oximeters determine the oxygen saturation level of blood by measuring the light absorption of arterial blood. The sensor consists of red and infrared light sources and photodetectors. A method based on neural networks and wavelet analysis is developed for improved saturation estimation in the presence of sensor motion. Spectral and correlation functions of the dual channel oximetry data are used by a backpropagation neural network to characterize the type of motion. Amplitude ratios of red to infrared signals as a function of time scale are obtained from the multiresolution wavelet decomposition of the two-channel data. Motion class and amplitude ratios are then combined to obtain a short-time estimate of the oxygen saturation level. A final estimate of oxygen saturation is obtained by applying a 15 s smoothing filter on the short-time measurements based on 3.5 s windows sampled every 1.75 s. The design employs two backpropagation neural networks. The first neural network determines the motion characteristics and the second network determines the saturation estimate. Our approach utilizes waveform analysis in contrast to the standard algorithms that are based on the successful detection of peaks and troughs in the signal. The proposed algorithm is numerically efficient and has stable characteristics with a reduced false alarm rate with a small loss in detection. The method can be rapidly developed on a digital signal processing platform.

  12. Identifying individual sleep apnea/hypoapnea epochs using smartphone-based pulse oximetry.

    Science.gov (United States)

    Garde, Ainara; Dekhordi, Parastoo; Ansermino, J Mark; Dumont, Guy A

    2016-08-01

    Sleep apnea, characterized by frequent pauses in breathing during sleep, poses a serious threat to the healthy growth and development of children. Polysomnography (PSG), the gold standard for sleep apnea diagnosis, is resource intensive and confined to sleep laboratories, thus reducing its accessibility. Pulse oximetry alone, providing blood oxygen saturation (SpO2) and blood volume changes in tissue (PPG), has the potential to identify children with sleep apnea. Thus, we aim to develop a tool for at-home sleep apnea screening that provides a detailed and automated 30 sec epoch-by-epoch sleep apnea analysis. We propose to extract features characterizing pulse oximetry (SpO2 and pulse rate variability [PRV], a surrogate measure of heart rate variability) to create a multivariate logistic regression model that identifies epochs containing apnea/hypoapnea events. Overnight pulse oximetry was collected using a smartphone-based pulse oximeter, simultaneously with standard PSG from 160 children at the British Columbia Children's hospital. The sleep technician manually scored all apnea/hypoapnea events during the PSG study. Based on these scores we labeled each epoch as containing or not containing apnea/hypoapnea. We randomly divided the subjects into training data (40%), used to develop the model applying the LASSO method, and testing data (60%), used to validate the model. The developed model was assessed epoch-by-epoch for each subject. The test dataset had a median area under the receiver operating characteristic (ROC) curve of 81%; the model provided a median accuracy of 74% sensitivity of 75%, and specificity of 73% when using a risk threshold similar to the percentage of apnea/hypopnea epochs. Thus, providing a detailed epoch-by-epoch analysis with at-home pulse oximetry alone is feasible with accuracy, sensitivity and specificity values above 73% However, the performance might decrease when analyzing subjects with a low number of apnea/hypoapnea events.

  13. Neuroprotection of hyperbaric oxygen therapy in sub-acute traumatic brain injury: not by immediately improving cerebral oxygen saturation and oxygen partial pressure.

    Science.gov (United States)

    Zhou, Bao-Chun; Liu, Li-Jun; Liu, Bing

    2016-09-01

    Although hyperbaric oxygen (HBO) therapy can promote the recovery of neural function in patients who have suffered traumatic brain injury (TBI), the underlying mechanism is unclear. We hypothesized that hyperbaric oxygen treatment plays a neuroprotective role in TBI by increasing regional transcranial oxygen saturation (rSO 2 ) and oxygen partial pressure (PaO 2 ). To test this idea, we compared two groups: a control group with 20 healthy people and a treatment group with 40 TBI patients. The 40 patients were given 100% oxygen of HBO for 90 minutes. Changes in rSO 2 were measured. The controls were also examined for rSO 2 and PaO 2 , but received no treatment. rSO 2 levels in the patients did not differ significantly after treatment, but levels before and after treatment were significantly lower than those in the control group. PaO 2 levels were significantly decreased after the 30-minute HBO treatment. Our findings suggest that there is a disorder of oxygen metabolism in patients with sub-acute TBI. HBO does not immediately affect cerebral oxygen metabolism, and the underlying mechanism still needs to be studied in depth.

  14. Study of Al-Si Alloy Oxygen Saturation on Its Microstructure and Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Arkady Finkelstein

    2017-07-01

    Full Text Available One of the main goals of modern materials research is obtaining different microstructures and studying their influence on the mechanical properties of metals; aluminum alloys are particularly of interest due to their advanced performance. Traditionally, their required properties are obtained by alloying process, modification, or physical influence during solidification. The present work describes a saturation of the overheated AlSi7Fe1 casting alloy by oxides using oxygen blowing approach in overheated alloy. Changes in metals’ microstructural and mechanical properties are also described in the work. An Al10SiFe intermetallic complex compound was obtained as a preferable component to Al2O3 precipitation on it, and its morphology was investigated by scanning electron microscopy. The mechanical properties of the alloy after the oxygen blowing treatment are discussed in this work.

  15. Study of Al-Si Alloy Oxygen Saturation on Its Microstructure and Mechanical Properties.

    Science.gov (United States)

    Finkelstein, Arkady; Schaefer, Arseny; Chikova, Оlga; Borodianskiy, Konstantin

    2017-07-11

    One of the main goals of modern materials research is obtaining different microstructures and studying their influence on the mechanical properties of metals; aluminum alloys are particularly of interest due to their advanced performance. Traditionally, their required properties are obtained by alloying process, modification, or physical influence during solidification. The present work describes a saturation of the overheated AlSi₇Fe₁ casting alloy by oxides using oxygen blowing approach in overheated alloy. Changes in metals' microstructural and mechanical properties are also described in the work. An Al 10 SiFe intermetallic complex compound was obtained as a preferable component to Al₂O₃ precipitation on it, and its morphology was investigated by scanning electron microscopy. The mechanical properties of the alloy after the oxygen blowing treatment are discussed in this work.

  16. Classification methods to detect sleep apnea in adults based on respiratory and oximetry signals: a systematic review.

    Science.gov (United States)

    Uddin, M B; Chow, C M; Su, S W

    2018-03-26

    Sleep apnea (SA), a common sleep disorder, can significantly decrease the quality of life, and is closely associated with major health risks such as cardiovascular disease, sudden death, depression, and hypertension. The normal diagnostic process of SA using polysomnography is costly and time consuming. In addition, the accuracy of different classification methods to detect SA varies with the use of different physiological signals. If an effective, reliable, and accurate classification method is developed, then the diagnosis of SA and its associated treatment will be time-efficient and economical. This study aims to systematically review the literature and present an overview of classification methods to detect SA using respiratory and oximetry signals and address the automated detection approach. Sixty-two included studies revealed the application of single and multiple signals (respiratory and oximetry) for the diagnosis of SA. Both airflow and oxygen saturation signals alone were effective in detecting SA in the case of binary decision-making, whereas multiple signals were good for multi-class detection. In addition, some machine learning methods were superior to the other classification methods for SA detection using respiratory and oximetry signals. To deal with the respiratory and oximetry signals, a good choice of classification method as well as the consideration of associated factors would result in high accuracy in the detection of SA. An accurate classification method should provide a high detection rate with an automated (independent of human action) analysis of respiratory and oximetry signals. Future high-quality automated studies using large samples of data from multiple patient groups or record batches are recommended.

  17. Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock

    OpenAIRE

    Mo?ina, Hugo; Podbregar, Matej

    2010-01-01

    Introduction Discrepancies of 5-24% between superior vena cava oxygen saturation (ScvO2) and mixed venous oxygen saturation (SvO2) have been reported in patients with severe heart failure. Thenar muscle tissue oxygenation (StO2) measured with near-infrared spectroscopy (NIRS) during arterial occlusion testing decreases slower in sepsis/septic shock patients (lower StO2 deoxygenation rate). The StO2 deoxygenation rate is influenced by dobutamine. The aim of this study was to determine the rela...

  18. [Sedation with intravenous midazolam during upper gastrointestinal endoscopy--changes in hemodynamics, oxygen saturation and memory].

    Science.gov (United States)

    Mizuno, Ju; Matsuki, Michiko; Gouda, Yoshinori; Nishiyama, Tomoki; Hanaoka, Kazuo

    2003-09-01

    Cardiorespiratory adverse effects are often observed in patients undergoing upper gastrointestinal endoscopy with sedation. In this study, we examined hemodynamics, oxygen saturation and memory during upper gastrointestinal endoscopy under sedation with intravenous midazolam. Eight healthy outpatients without any obvious complications received intravenous midazolam 5 mg for sedation for upper gastrointestinal endoscopy. Blood pressure, heart rate and percutaneous arterial oxygen saturation (SpO2) were measured before, during and after endoscopy. After the arousal by intravenous flumazenil, we inquired the patients about the level of memory during the endoscopy. Blood pressure decreased significantly two minutes after midazolam administration, but increased significantly after the insertion of an endoscope which was not different from the control value. Heart rate increased significantly one and three minutes after the insertion of the endoscope. SpO2 decreased significantly after midazolam administration and stayed at around 95%. No patients remembered the procedure. Sedation with intravenous midazolam during upper gastrointestinal endoscopy is useful to control the cardiovascular responses, and to obtain amnesia. However, a decrease in SpO2 should be watched carefully.

  19. Macular Retinal Vessel Oxygen Saturation Elevation in Chinese Central Serous Chorioretinopathy

    Directory of Open Access Journals (Sweden)

    Cheng Li

    2017-01-01

    Full Text Available Purpose. To evaluate the retinal vessel oxygen saturation in central serous chorioretinopathy (CSC cases among the Chinese. Methods. Relative oxygen saturation of retinal blood vessels was measured in 33 Chinese patients with single-eye CSC using the Oxymap T1 retinal oximeter. The contralateral eyes were the control. The mean saturation of the retinal arteriole (AS and venule (VS, arteriovenous difference (AVS, and arteriole and venule diameters (AD, VD was analyzed in the optic disc area and macular region. Results. In the optic disc area, the inferotemporal quadrant (TI AS (93.2 ± 10.2% and inferonasal quadrant (NI VS (61.3 ± 7.3% were higher in the affected eyes than in the contralateral eyes (88.7 ± 7.7% and 56.9 ± 6.5% and AVS in NI (36.7 ± 10.4% decreased compared to the contralateral eyes (41.5 ± 11.2%. The VD in TI was expanded (19.9 ± 2.5 pixels versus 18.1 ± 3.4 pixels. Around the macular region, AS was 93.6 ± 7.6%, higher than in the contralateral eyes (89.5 ± 6.3%. No other significant changes were found. Conclusions. AS increased in the TI, and VS decreased in the NI in the eyes with CSC. In addition, AS also increased around the macular region, suggesting that these are contributors to CSC pathophysiology.

  20. Central venous oxygen saturation in septic shock - a marker of cardiac output, microvascular shunting and/or dysoxia?

    DEFF Research Database (Denmark)

    Haase, Nicolai; Perner, Anders

    2011-01-01

    Shock therapy aims at increasing central venous oxygen saturation (ScvO2), which is a marker of inadequate oxygen delivery. In this issue of Critical Care, Textoris and colleagues challenge this notion by reporting that high levels of ScvO2 are associated with mortality in patients with septic sh...

  1. Growth of the microalgae Neochloris oleoabundans at high partial oxygen pressures and sub-saturating light intensity

    NARCIS (Netherlands)

    Sousa, C.A.; Winter, de L.; Janssen, M.G.J.; Vermue, M.H.; Wijffels, R.H.

    2012-01-01

    The effect of partial oxygen pressure on growth of Neochloris oleoabundans was studied at sub-saturating light intensity in a fully-controlled stirred tank photobioreactor. At the three partial oxygen pressures tested (PO2=0.24; 0.63; 0.84 bar), the specific growth rate was 1.38; 1.36 and 1.06

  2. The effect of sensory stimulation provided by family on arterial blood oxygen saturation in critical care patients.

    Science.gov (United States)

    Yousefi, Hojatollah; Naderi, Mojgan; Daryabeigi, Reza

    2015-01-01

    Stressors in the intensive care unit (ICU) impair patients' comfort, excite the stress response, and increase oxygen consumption in their body. Non-medical interventions are recommended by several studies as a treatment to improve comfort in the ICU patients. Sensory stimulation is one of the most important interventions. Since arterial blood oxygen saturation is an important index of patients' clinical and respiratory condition, this study aimed to investigate the effect of sensory stimulation provided by family on arterial blood oxygen saturation in critical care patients. This study is a clinical trial conducted on 64 patients hospitalized in the ICU wards of Al-Zahra and Kashani hospitals in Isfahan, Iran in 2012 and 2013. The patients were selected by simple sampling method and were randomly assigned to two groups (study and control). Patients' arterial blood oxygen saturations were measured 10 min before, immediately after, 10 min and 30 min after sensory stimulation in the study group, and simultaneously in the control group without any intervention. Repeated measures analysis of variance (ANOVA) showed a significant difference in the mean of arterial blood oxygen saturation levels 10 min before, immediately after, 10 min and 30 min after sensory stimulation in the study group (P 0.18). Application of sensory stimulations as a nursing and non-medical intervention by the family members improves comfort and increases the level of blood oxygen saturation in critical care patients.

  3. Validation of NIRS in measuring tissue hemoglobin concentration and oxygen saturation on ex vivo and isolated limb models

    Science.gov (United States)

    Xu, Xiaorong; Zhu, Wen; Padival, Vikram; Xia, Mengna; Cheng, Xuefeng; Bush, Robin; Christenson, Linda; Chan, Tim; Doherty, Tim; Iatridis, Angelo

    2003-07-01

    Photonify"s tissue spectrometer uses Near-Infrared Spectroscopy for real-time, noninvasive measurement of hemoglobin concentration and oxygen saturation [SO2] of biological tissues. The technology was validated by a series of ex vivo and animal studies. In the ex vivo experiment, a close loop blood circulation system was built, precisely controlling the oxygen saturation and the hemoglobin concentration of a liquid phantom. Photonify"s tissue spectrometer was placed on the surface of the liquid phantom for real time measurement and compared with a gas analyzer, considered the gold standard to measure oxygen saturation and hemoglobin concentration. In the animal experiment, the right hind limb of each dog accepted onto the study was surgically removed. The limb was kept viable by connecting the femoral vein and artery to a blood-primed extracorporeal circuit. Different concentrations of hemoglobin were obtained by adding designated amount of saline solution into the perfusion circuit. Photonify"s tissue spectrometers measured oxygen saturation and hemoglobin concentration at various locations on the limb and compared with gas analyzer results. The test results demonstrated that Photonify"s tissue spectrometers were able to detect the relative changes in tissue oxygen saturation and hemoglobin concentration with a high linear correlation compared to the gas analyzer

  4. An in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor.

    Science.gov (United States)

    Hickey, Michelle; Samuels, Neal; Randive, Nilesh; Langford, Richard M; Kyriacou, Panayiotis A

    2011-05-01

    The continuous monitoring of splanchnic organ oxygen saturation could make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischemia, multiple organ failure, and, ultimately, death. Current methods for assessing splanchnic perfusion have not been widely accepted for use in the clinical care environment. In an attempt to overcome the limitations of the current techniques, a new fiberoptic photoplethysmographic (PPG)/pulse oximetry sensor was developed as a means of assessing splanchnic organ perfusion during surgery in humans. A new fiberoptic splanchnic pulse oximeter and an optically identical fiberoptic finger pulse oximeter have been developed. Simultaneous PPG signals and preliminary estimates of arterial oxygen saturation from the bowel (small and large) and finger were obtained in 17 patients (3 men and 14 women) undergoing open laparotomy. Good quality PPG signals were obtained from the small and large bowel and from the finger in all patients (lower 95% confidence limit for the proportion was 0.64). Comparisons of blood oxygen saturation values acquired when using the splanchnic and the finger fiberoptic sensors and a commercial finger pulse oximeter indicated that there was no statistically significant difference between them (all P>0.454). A Bland and Altman plot of the difference between blood oxygen saturation values from the bowel fiberoptic pulse oximeter and the fiberoptic finger pulse oximeter against their mean showed that the limits of agreement between the 2 pulse oximeters were -3.8% and 4.2% for small bowel measurements, and -3.4% and 4.3% for large bowel measurements. The 95% prediction interval for the difference between the 2 devices was between -4.2% and 4.7%. This study demonstrated that good quality PPG signals can be obtained from the bowel using a new fiberoptic sensor. Further evaluation is required to determine whether fiberoptic pulse oximetry of the bowel may provide a

  5. Oxygen saturation in children with and without obstructive sleep apnea using the phone-oximeter.

    Science.gov (United States)

    Garde, Ainara; Karlen, Walter; Dehkordi, Parastoo; Wensley, David; Ansermino, J Mark; Dumont, Guy A

    2013-01-01

    Obstructive sleep apnea (OSA) in children can lead to daytime sleepiness, growth failure and developmental delay. Polysomnography (PSG), the gold standard to diagnose OSA is highly resource intensive and is confined to the sleep laboratory. In this study we propose to identify children with OSA using blood oxygen saturation (SpO2) obtained from the Phone Oximeter. This portable, in-home device is able to monitor patients over multiple nights, causes less sleep disturbance and facilitates a more natural sleep pattern. The proposed algorithm analyzes the SpO2 signal in the time and frequency domain using a 90-s sliding window. Three spectral parameters are calculated from the power spectral density (PSD) to evaluate the modulation in the SpO2 due to the oxyhemoblobin desaturations. The power P, slope S in the discriminant band (DB), and ratio R between P and total power are calculated for each window. Tendency and variability indices, number of SpO2 desaturations and time spent under 2% or 3% of baseline saturation level are computed for each time window. The statistical distribution of the temporal evolution of all parameters is analyzed to identify 68 children, 30 with OSA and 38 without OSA (nonOSA). This characterization was evaluated by a feature selection based on a linear discriminant. The combination of temporal and spectral parameters provided the best leave one out crossvalidation results with an accuracy of 86.8%, a sensitivity of 80.0%, and a specificity of 92.1% using only 5 parameters. The median of R, mean of P and S and mean and standard deviation of the number of desaturations below 3% of baseline saturation level, were the most representative parameters. Hence, a better knowledge of SpO2 dynamics could help identifying children with OSA with the Phone Oximeter.

  6. Examination of Pulse Oximetry Tracings to Detect Obstructive Sleep Apnea in Patients with Advanced Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Adrienne S Scott

    2014-01-01

    Full Text Available Nocturnal hypoxemia and obstructive sleep apnea (OSA are common comorbidities in patients with chronic obstructive pulmonary disease (COPD. The authors sought to develop a strategy to interpret nocturnal pulse oximetry and assess its capacity for detection of OSA in patients with stage 3 to stage 4 COPD. A review of consecutive patients with COPD who were clinically prescribed oximetry and polysomnography was conducted. OSA was diagnosed if the polysomnographic apnea-hypopnea index was >15 events/h. Comprehensive criteria were developed for interpretation of pulse oximetry tracings through iterative validation and interscorer concordance of ≥80%. Criteria consisted of visually identified desaturation ‘events’ (sustained desaturation ≥4%, 1 h time scale, ‘patterns’ (≥3 similar desaturation/saturation cycles, 15 min time scale and the automated oxygen desaturation index. The area under the curve (AUC, sensitivity, specificity and accuracy were calculated. Of 59 patients (27 male, 31 had OSA (53%. The mean forced expiratory volume in 1 s was 46% of predicted (range 21% to 74% of predicted and 52% of patients were on long-term oxygen therapy. Among 59 patients, 35 were correctly identified as having OSA or not having OSA, corresponding to an accuracy of 59%, with a sensitivity and specificity of 59% and 60%, respectively. The AUC was 0.57 (95% CI 0.55 to 0.59. Using software-computed desaturation events (hypoxemia ≥4% for ≥10 s indexed at ≥15 events/h of sleep as diagnostic criteria, sensitivity was 60%, specificity was 63% and the AUC was 0.64 (95%CI 0.62 to 0.66. No single criterion demonstrated important diagnostic utility. Pulse oximetry tracing interpretation had a modest diagnostic value in identifying OSA in patients with moderate to severe COPD.

  7. Near-simultaneous hemoglobin saturation and oxygen tension maps in mouse brain using an AOTF microscope.

    Science.gov (United States)

    Shonat, R D; Wachman, E S; Niu, W; Koretsky, A P; Farkas, D L

    1997-09-01

    A newly developed microscope using acousto-optic tunable filters (AOTFs) was used to generate in vivo hemoglobin saturation (SO2) and oxygen tension (PO2) maps in the cerebral cortex of mice. SO2 maps were generated from the spectral analysis of reflected absorbance images collected at different wavelengths, and PO2 maps were generated from the phosphorescence lifetimes of an injected palladium-porphyrin compound using a frequency-domain measurement. As the inspiratory O2 was stepped from hypoxia (10% O2), through normoxia (21% O2), to hyperoxia (60% O2), measured SO2 and PO2 levels rose accordingly and predictably throughout. A plot of SO2 versus PO2 in different arterial and venous regions of the pial vessels conformed to the sigmoidal shape of the oxygen-hemoglobin dissociation curve, providing further validation of the two mapping procedures. The study demonstrates the versatility of the AOTF microscope for in vivo physiologic investigation, allowing for the generation of nearly simultaneous SO2 and PO2 maps in the cerebral cortex, and the frequency-domain detection of phosphorescence lifetimes. This class of study opens up exciting new possibilities for investigating the dynamics of hemoglobin and O2 binding during functional activation of neuronal tissues.

  8. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation.

    Science.gov (United States)

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-09-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C.Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland-Altman method was used to assess agreement between them.The devices showed agreement in overall tracking of changes in SO2. Test-retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range.Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative.

  9. Inspiratory Muscle Training and Arterial Blood Oxygen Saturation in Patients With Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Bakhshandeh Bavarsad

    2015-01-01

    Full Text Available Background One of the problems of the patients with chronic obstructive pulmonary disease (COPD is the weakness of the respiratory muscles that causes oxygen desaturation at rest and activity and decreases exercise tolerance. Objectives This study aimed to investigate the effect of inspiratory muscle training on arterial oxygen saturation (SPO2. Patients and Methods Forty patients with mild to very severe COPD were recruited for this study, which is a randomized control trail. The patients were randomized to IMT (inspiratory muscle training and control group. Training was performed with Respivol (a kind of inspiratory muscle trainer for 8 weeks (15 min/d for 6 d/week. SPSS software version 16 was used to analyze the data by performing independent t test, paired t test, and Fisher exact test. Results Results showed that, after 8 weeks of inspiratory muscle training, there was a little increase (but not statistically significant improvement in SPO2 (from 92.6 ± 8.71 % to 95.13 ± 7.08 %, with P = 0.06, whereas it remained unchanged in the control group (from 96.0 ± 3.46 % to 96.4 ± 3.35 % with P = 0.51. No statistically significant difference was seen between the two groups (P > 0.05. Conclusions Although inspiratory muscles training can prevent desaturation, which is caused by activity, it fails to improve it.

  10. Nanoparticle-enhanced spectral photoacoustic tomography: effect of oxygen saturation and tissue heterogeneity

    Science.gov (United States)

    Vogt, William C.; Jia, Congxian; Wear, Keith A.; Garra, Brian S.; Pfefer, T. Joshua

    2016-03-01

    Molecular imaging for breast cancer detection, infectious disease diagnostics and preclinical animal research may be achievable through combined use of targeted exogenous agents - such as nanoparticles - and spectral Photoacoustic Tomography (PAT). However, tissue heterogeneity can alter fluence distributions and acoustic propagation, corrupting measured PAT absorption spectra and complicating in vivo nanoparticle detection and quantitation. Highly absorptive vascular structures represent a common confounding factor, and variations in vessel hemoglobin saturation (SO2) may alter spectral content of signals from adjacent/deeper regions. To evaluate the impact of this effect on PAT nanoparticle detectability, we constructed heterogeneous phantoms with well-characterized channel-inclusion geometries and biologically relevant optical and acoustic properties. Phantoms contained an array of tubes at several depths filled with hemoglobin solutions doped with varying concentrations of gold nanorods with an absorption peak at 780 nm. Both overlying and target network SO2 was tuned using sodium dithionite. Phantoms were imaged from 700 to 900 nm using a custom PAT system comprised of a tunable pulsed laser and a research-grade ultrasound system. Recovered nanoparticle spectra were analyzed and compared with results from both spectrophotometry and PAT data from waterimmersed tubes containing blood and nanoparticle solutions. Results suggested that nanoparticle selection for a given PAT application should take into account expected oxygenation states of both target blood vessel and background tissue oxygenation to achieve optimal performance.

  11. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation

    International Nuclear Information System (INIS)

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-01-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C. Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland–Altman method was used to assess agreement between them. The devices showed agreement in overall tracking of changes in SO2. Test–retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range. Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative. (paper)

  12. Investigation of spatial resolution dependent variability in transcutaneous oxygen saturation using point spectroscopy system

    Science.gov (United States)

    Philimon, Sheena P.; Huong, Audrey K. C.; Ngu, Xavier T. I.

    2017-08-01

    This paper aims to investigate the variation in one’s percent mean transcutaneous oxygen saturation (StO2) with differences in spatial resolution of data. This work required the knowledge of extinction coefficient of hemoglobin derivatives in the wavelength range of 520 - 600 nm to solve for the StO2 value via an iterative fitting procedure. A pilot study was conducted on three healthy subjects with spectroscopic data collected from their right index finger at different arbitrarily selected distances. The StO2 value estimated by Extended Modified Lambert Beer (EMLB) model revealed a higher mean StO2 of 91.1 ± 1.3% at a proximity distance of 30 mm compared to 60.83 ± 2.8% at 200 mm. The results showed a high correlation between data spatial resolution and StO2 value, and revealed a decrease in StO2 value as the sampling distance increased. The preliminary findings from this study contribute to the knowledge of the appropriate distance range for consistent and high repeatability measurement of skin oxygenation.

  13. A new fibre optic pulse oximeter probe for monitoring splanchnic organ arterial blood oxygen saturation.

    Science.gov (United States)

    Hickey, M; Samuels, N; Randive, N; Langford, R; Kyriacou, P A

    2012-12-01

    A new, continuous method of monitoring splanchnic organ oxygen saturation (SpO(2)) would make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischaemia, and, ultimately, death. In an attempt to provide such a device, a new fibre optic based reflectance pulse oximeter probe and processing system were developed followed by an in vivo evaluation of the technology on seventeen patients undergoing elective laparotomy. Photoplethysmographic (PPG) signals of good quality and high signal-to-noise ratio were obtained from the small bowel, large bowel, liver and stomach. Simultaneous peripheral PPG signals from the finger were also obtained for comparison purposes. Analysis of the amplitudes of all acquired PPG signals indicated much larger amplitudes for those signals obtained from splanchnic organs than those obtained from the finger. Estimated SpO(2) values for splanchnic organs showed good agreement with those obtained from the finger fibre optic probe and those obtained from a commercial device. These preliminary results suggest that a miniaturized 'indwelling' fibre optic sensor may be a suitable method for pre-operative and post-operative evaluation of splanchnic organ SpO(2) and their health. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. Evaluation of arterial oxygen saturation using RGB camera-based remote photoplethysmography

    Science.gov (United States)

    Nishidate, Izumi; Nakano, Kazuya; McDuff, Daniel; Niizeki, Kyuichi; Aizu, Yoshihisa; Haneishi, Hideaki

    2018-02-01

    Plethysmogram is the periodic variation in blood volume due to the cardiac pulse traveling through the body. Photo-plethysmograph (PPG) has been widely used to assess the cardiovascular system such as heart rate, blood pressure, cardiac output, vascular compliance. We have previously proposed a non-contact PPG imaging method using a digital red-green-blue camera. In the method, the Monte Carlo simulation for light transport is used to specify a relationship among the RGB-values and the concentrations of oxygenated hemoglobin (CHbO) and deoxygenated hemoglobin (CHbR). The total hemoglobin concentration (CHbT) can be calculated as a sum of CHbO and CHbR. Applying the fast Fourier transform (FFT) band pass filters to each pixel of the sequential images for CHbT along the time line, two-dimentional plethysmogram can be reconstructed. In this study, we further extend the method to imaging the arterial oxygen saturation (SaO2). The PPG signals for both CHbO and CHbR are extracted by the FFT band pass filter and the pulse wave amplitudes (PWAs) of CHbO and CHbR are calculated. We assume that the PWA for CHbO and that for CHbR are decreased and increased as SaO2 is decreased. The ratio of PWA for CHbO and that for CHbR are associated to the reference value of SaO2 measured by a commercially available pulse oximeter, which provide an empirical formula to estimate SaO2 from the PPG signal at each pixel of RGB image. In vivo animal experiments with rats during varying the fraction of inspired oxygen (FiO2) demonstrated the feasibility of the proposed method.

  15. Nitric oxide formation from the reaction of nitrite with carp and rabbit hemoglobin at intermediate oxygen saturations

    DEFF Research Database (Denmark)

    Jensen, Frank Bo

    2008-01-01

    The nitrite reductase activity of deoxyhemoglobin has received much recent interest because the nitric oxide produced in this reaction may participate in blood flow regulation during hypoxia. The present study used spectral deconvolution to characterize the reaction of nitrite with carp and rabbit...... hemoglobin at different constant oxygen tensions that generate the full range of physiological relevant oxygen saturations. Carp is a hypoxia-tolerant species with very high hemoglobin oxygen affinity, and the high R-state character and low redox potential of the hemoglobin is hypothesized to promote...... NO generation from nitrite. The reaction of nitrite with deoxyhemoglobin leads to a 1 : 1 formation of nitrosylhemoglobin and methemoglobin in both species. At intermediate oxygen saturations, the reaction with deoxyhemoglobin is clearly favored over that with oxyhemoglobin, and the oxyhemoglobin reaction...

  16. The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources.

    Science.gov (United States)

    Mou, Ling; Gong, Quan; Wei, Wei; Gao, Bo

    2013-06-01

    The photoplethysmography (PPG) signals detected by transesophageal oximetry sensor toward aorta arch (AA), descending aorta (DA), and left ventricle (LV) under the guidance of transesophageal echocardiography (TEE) were investigated, and the effects of filter application on PPG signals were evaluated. Eleven cardiac surgical patients were involved. After anesthesia was induced, the TEE probe with a modified pulse oximetry sensor was inserted. Under the guidance of TEE, the AA PPG, DA PPG and LV PPG were detected respectively when ventilator was on and off. The mean alternating current (AC) amplitudes and direct current (DC) values of original and filtered PPG signals were measured. The ratio of AC and DC value (AC/DC) and ventilation-induced AC variations were calculated. Satisfactory PPG waveforms were obtained in all patients under the guidance of TEE. The AC amplitude in LV PPG was significant larger than in AA and DA PPG, and both AC/DC and ventilation-induced AC variation in LV PPG were significantly higher than in AA PPG or DA PPG either. There were no significant differences of AC amplitude between filtered and ventilation off PPG signals. The AC amplitudes and AC/DC toward LV are significantly higher than transesophageal oximeter toward AA or DA, and the effect of mechanical ventilation on transesophageal PPG can be obviously reduced by filtering techniques.

  17. [transcutaneous oximetry--between theory and practice].

    Science.gov (United States)

    Zulec, Mirna

    2014-10-01

    Transcutaneous oximetry is a procedure used to measure the pressure of oxygen in tissue and to determine oxygenation level. It is essential to determine the state of microcirculation and is used to assess the necessity and level of amputation and the effect of revascularization procedures, as a predictor of wound healing and hyperbaric oxygen therapy (HBOT) effectiveness tool. The measurement is done by the application electrode measuring point and the result is measured in mm Hg. Tissue with adequate oxygen level has a value greater than 50 mm Hg. Values between 20 and 40 mm Hg are considered hypoxic, while those below 20 mm Hg indicate extreme hypoxia. In Croatia, TcPO2 is commonly used for HBOT assessment but there is the need of broader application to objectify and facilitate procedures in the care of persons with impaired microcirculation.

  18. Intrauterine Methylene Blue Injection Influences the Accuracy of Pulse Oximetry Readings

    Directory of Open Access Journals (Sweden)

    Fuh-Cheng Yeh

    2005-12-01

    Conclusions: Intraoperative administration of methylene blue may induce false low readings on pulse oximetry. The patient was not hypoxemic. If there is any doubt, arterial blood gas analysis should be done to ensure that the patient is well oxygenated.

  19. Comparison of emissions and performance between saturated cyclic oxygenates and aromatics in a heavy-duty diesel engine

    NARCIS (Netherlands)

    Zhou, L.; Boot, M.D.; Johansson, B.H.

    2013-01-01

    Emissions and fuel economy are evaluated for two types of biofuels, namely 2-phenyl ethanol and cyclohexaneethanol. Both are derived from lignin, a form of lignocellulosic biomass. The former and latter oxygenates have an aromatic and aliphatic (i.e. saturated) ring structure, respectively. Two

  20. The effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing total knee replacement surgery.

    Science.gov (United States)

    Song, Inkyung; Kim, Dong Yeon; Kim, Youn Jin

    2012-11-01

    Inflation and deflation of a pneumatic tourniquet used in total knee replacement surgery induces various changes in patient's hemodynamic and metabolic status, which may result in serious complications, especially in aged patients. Near-infrared spectroscopy (NIRS) is a monitoring device designed to estimate the regional cerebral oxygen saturation. We evaluated the effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing total knee replacement surgery, using NIRS. Twenty-eight American Society of Anesthesiologists physical status I or II patients, over the age of sixty-five years undergoing total knee replacement surgery, were included. Under general anesthesia, the mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), stroke volume (SV), and regional cerebral oxygen saturation (rSO(2)) were recorded before induction of anesthesia and every 2 min after tourniquet deflation for 20 min. Arterial blood gas analysis was performed 5 min before, in addition to 0, and 10 min after tourniquet deflation. The decrease of rSO(2) was not significant during 20-min deflation period. MAP, CO and SV showed significant decrease during 2 to 12, 4 to 6 and 2 to 6-min period after tourniquet deflation, respectively (P deflation caused significant changes in hemodynamic and metabolic status, but not in regional cerebral oxygen saturation. It is recommended to monitor neurologic status, as well as hemodynamic and metabolic status to avoid serious complications, especially in aged patients.

  1. Short-term Effects of Air Pollution on Oxygen Saturation in a Cohort of Senior Adults in Steubenville, OH

    Science.gov (United States)

    Luttmann-Gibson, Heike; Sarnat, Stefanie Ebelt; Suh, Helen H.; Coull, Brent A.; Schwartz, Joel; Zanobetti, Antonella; Gold, Diane R.

    2014-01-01

    Objective We examine whether ambient air pollution is associated with oxygen saturation in 32 elderly subjects in Steubenville. Methods We used linear mixed models to examine the effects of fine particles (PM2.5), sulfate (SO42-), elemental carbon (EC), and gases on median oxygen saturation. Results An interquartile range (IQR) increase of 13.4 μg/m3 in PM2.5 on the previous day was associated with a decrease of -0.18% (95% CI: -0.31 to -0.06), and a 5.1 μg/m3 IQR increase in SO42- on the previous day was associated with a decrease of -0.16% (95% CI: -0.27 to -0.04) in oxygen saturation during the initial 5-min rest period of the protocol. Conclusions Increased exposure to air pollution, including the non-traffic pollutant SO42- from industrial sources, led to changes in oxygen saturation that may reflect particle-induced pulmonary inflammatory or vascular responses. PMID:24451609

  2. Short-term effects of air pollution on oxygen saturation in a cohort of senior adults in Steubenville, Ohio.

    Science.gov (United States)

    Luttmann-Gibson, Heike; Sarnat, Stefanie Ebelt; Suh, Helen H; Coull, Brent A; Schwartz, Joel; Zanobetti, Antonella; Gold, Diane R

    2014-02-01

    We examine whether ambient air pollution is associated with oxygen saturation in 32 elderly subjects in Steubenville, Ohio. We used linear mixed models to examine the effects of fine particulate matter less than 2.5 μm (PM(2.5)), sulfate (SO(4)(-2)), elemental carbon, and gases on median oxygen saturation. An interquartile range increase of 13.4 μg/m in PM(2.5) on the previous day was associated with a decrease of -0.18% (95% confidence interval: -0.31 to -0.06) and a 5.1 μg/m(3) interquartile range increase in SO(4)(-2) on the previous day was associated with a decrease of -0.16% (95% confidence interval: -0.27 to -0.04) in oxygen saturation during the initial 5-minute rest period of the protocol. Increased exposure to air pollution, including the nontraffic pollutant SO(4)(-2) from industrial sources, led to changes in oxygen saturation that may reflect particle-induced pulmonary inflammatory or vascular responses.

  3. T2-prepared velocity selective labelling : A novel idea for full-brain mapping of oxygen saturation

    NARCIS (Netherlands)

    Alderliesten, Thomas; De Vis, Jill B; Lemmers, Petra M A; van Bel, Frank; Benders, Manon J N L; Hendrikse, Jeroen; Petersen, Esben T

    2016-01-01

    BACKGROUND AND AIM: Disturbances in cerebral oxygenation saturation (SO2) have been linked to adverse outcome in adults, children, and neonates. In intensive care, the cerebral SO2 is increasingly being monitored by Near-InfraRed Spectroscopy (NIRS). Unfortunately NIRS has a limited penetration

  4. Higher cerebral oxygen saturation may provide higher urinary output during continuous regional cerebral perfusion

    Directory of Open Access Journals (Sweden)

    Tomoyasu Takahiro

    2008-10-01

    Full Text Available Abstract Objective We examined the hypothesis that higher cerebral oxygen saturation (rSO2 during RCP is correlated with urinary output. Methods Between December 2002 and August 2006, 12 patients aged 3 to 61 days and weighing 2.6 to 3.4 kg underwent aortic arch repair with RCP. Urinary output and rSO2 were analyzed retrospectively. Data were assigned to either of 2 groups according to their corresponding rSO2: Group A (rSO2 ≦ 75% and Group B (rSO2 Results Seven and 5 patients were assigned to Group A and Group B, respectively. Group A was characterized by mean radial arterial pressure (37.9 ± 9.6 vs 45.8 ± 7.8 mmHg; P = 0.14 and femoral arterial pressure (6.7 ± 6.1 vs 20.8 ± 14.6 mmHg; P = 0.09 compared to Group B. However, higher urinary output during CPB (1.03 ± 1.18 vs 0.10 ± 0.15 ml·kg-1·h-1; P = 0.03. Furthermore our results indicate that a higher dose of Chlorpromazine was used in Group A (2.9 ± 1.4 vs 1.7 ± 1.0 mg/kg; P = 0.03. Conclusion Higher cerebral oxygenation may provide higher urinary output due to higher renal blood flow through collateral circulation.

  5. Reduced deep regional cerebral venous oxygen saturation in hemodialysis patients using quantitative susceptibility mapping.

    Science.gov (United States)

    Chai, Chao; Liu, Saifeng; Fan, Linlin; Liu, Lei; Li, Jinping; Zuo, Chao; Qian, Tianyi; Haacke, E Mark; Shen, Wen; Xia, Shuang

    2018-02-01

    Cerebral venous oxygen saturation (SvO 2 ) is an important indicator of brain function. There was debate about lower cerebral oxygen metabolism in hemodialysis patients and there were no reports about the changes of deep regional cerebral SvO 2 in hemodialysis patients. In this study, we aim to explore the deep regional cerebral SvO 2 from straight sinus using quantitative susceptibility mapping (QSM) and the correlation with clinical risk factors and neuropsychiatric testing . 52 hemodialysis patients and 54 age-and gender-matched healthy controls were enrolled. QSM reconstructed from original phase data of 3.0 T susceptibility-weighted imaging was used to measure the susceptibility of straight sinus. The susceptibility was used to calculate the deep regional cerebral SvO 2 and compare with healthy individuals. Correlation analysis was performed to investigate the correlation between deep regional cerebral SvO 2 , clinical risk factors and neuropsychiatric testing. The deep regional cerebral SvO 2 of hemodialysis patients (72.5 ± 3.7%) was significantly lower than healthy controls (76.0 ± 2.1%) (P deep regional cerebral SvO 2 in patients. The Mini-Mental State Examination (MMSE) scores of hemodialysis patients were significantly lower than healthy controls (P deep regional cerebral SvO 2 did not correlate with MMSE scores (P = 0.630). In summary, the decreased deep regional cerebral SvO 2 occurred in hemodialysis patients and dialysis duration, parathyroid hormone, hematocrit, hemoglobin and red blood cell may be clinical risk factors.

  6. Hyperspectral imaging with near-infrared-enabled mobile phones for tissue oximetry

    Science.gov (United States)

    Lin, Jonathan L.; Ghassemi, Pejhman; Chen, Yu; Pfefer, Joshua

    2018-02-01

    Hyperspectral reflectance imaging (HRI) is an emerging clinical tool for characterizing spatial and temporal variations in blood perfusion and oxygenation for applications such as burn assessment, wound healing, retinal exams and intraoperative tissue viability assessment. Since clinical HRI-based oximeters often use near-infrared (NIR) light, NIR-enabled mobile phones may provide a useful platform for future point-of-care devices. Furthermore, quantitative NIR imaging on mobile phones may dramatically increase the availability and accessibility of medical diagnostics for low-resource settings. We have evaluated the potential for phone-based NIR oximetry imaging and elucidated factors affecting performance using devices from two different manufacturers, as well as a scientific CCD. A broadband light source and liquid crystal tunable filter were used for imaging at 10 nm bands from 650 to 1000 nm. Spectral sensitivity measurements indicated that mobile phones with standard NIR blocking filters had minimal response beyond 700 nm, whereas one modified phone showed sensitivity to 800 nm and another to 1000 nm. Red pixel channels showed the greatest sensitivity up to 800 nm, whereas all channels provided essentially equivalent sensitivity at longer wavelengths. Referencing of blood oxygenation levels was performed with a CO-oximeter. HRI measurements were performed using cuvettes filled with hemoglobin solutions of different oxygen saturation levels. Good agreement between absorbance spectra measured with mobile phone and a CCD cameras were seen for wavelengths below 900 nm. Saturation estimates showed root-mean-squared-errors of 5.2% and 4.5% for the CCD and phone, respectively. Overall, this work provides strong evidence of the potential for mobile phones to provide quantitative spectral imaging in the NIR for applications such as oximetry, and generates practical insights into factors that impact performance as well as test methods for performance assessment.

  7. Assessment of muscle tissue oxygen saturation after out-of-hospital cardiac arrest.

    Science.gov (United States)

    Orban, Jean-Christophe; Scarlatti, Audrey; Danin, Pierre-Eric; Dellamonica, Jean; Bernardin, Gilles; Ichai, Carole

    2015-12-01

    Pathophysiology of cardiac arrest corresponds to an ischemia-reperfusion syndrome with deep impairment of microcirculation. Muscular tissue oxygen saturation (StO2) is a noninvasive method of evaluation of microcirculation. Our study was aimed at assessing the prognosis value of muscular StO2 in patients admitted for out-of-hospital cardiac arrest (OHCA) and treated with hypothermia. We conducted a prospective bicentric observational study including OHCA patients treated with therapeutic hypothermia. Baseline StO2, derived variables (desaturation and resaturation slopes), and lactate levels were compared at different times between patients with good and poor outcomes. Prognosis was assessed by the Cerebral Performance Category (CPC) score at 6 months after admission (CPC 1-2, good outcome; CPC 3-5, poor outcome). Forty-four patients were included, 17 good and 27 poor outcomes at 6 months. At admission, StO2 and lactate levels were lower in good outcome patients. Desaturation and resaturation slopes did not differ between groups. After an OHCA treated with therapeutic hypothermia, StO2 was correlated with outcome. Further research is needed to better understand the pathophysiological process underlying our results. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Development of theoretical oxygen saturation calibration curve based on optical density ratio and optical simulation approach

    Science.gov (United States)

    Jumadi, Nur Anida; Beng, Gan Kok; Ali, Mohd Alauddin Mohd; Zahedi, Edmond; Morsin, Marlia

    2017-09-01

    The implementation of surface-based Monte Carlo simulation technique for oxygen saturation (SaO2) calibration curve estimation is demonstrated in this paper. Generally, the calibration curve is estimated either from the empirical study using animals as the subject of experiment or is derived from mathematical equations. However, the determination of calibration curve using animal is time consuming and requires expertise to conduct the experiment. Alternatively, an optical simulation technique has been used widely in the biomedical optics field due to its capability to exhibit the real tissue behavior. The mathematical relationship between optical density (OD) and optical density ratios (ODR) associated with SaO2 during systole and diastole is used as the basis of obtaining the theoretical calibration curve. The optical properties correspond to systolic and diastolic behaviors were applied to the tissue model to mimic the optical properties of the tissues. Based on the absorbed ray flux at detectors, the OD and ODR were successfully calculated. The simulation results of optical density ratio occurred at every 20 % interval of SaO2 is presented with maximum error of 2.17 % when comparing it with previous numerical simulation technique (MC model). The findings reveal the potential of the proposed method to be used for extended calibration curve study using other wavelength pair.

  9. White Matter Damage Relates to Oxygen Saturation in Children With Sickle Cell Anemia Without Silent Cerebral Infarcts.

    Science.gov (United States)

    Kawadler, Jamie M; Kirkham, Fenella J; Clayden, Jonathan D; Hollocks, Matthew J; Seymour, Emma L; Edey, Rosanna; Telfer, Paul; Robins, Andrew; Wilkey, Olu; Barker, Simon; Cox, Tim C S; Clark, Chris A

    2015-07-01

    Sickle cell anemia is associated with compromised oxygen-carrying capability of hemoglobin and a high incidence of overt and silent stroke. However, in children with no evidence of cerebral infarction, there are changes in brain morphometry relative to healthy controls, which may be related to chronic anemia and oxygen desaturation. A whole-brain tract-based spatial statistics analysis was carried out in 25 children with sickle cell anemia with no evidence of abnormality on T2-weighted magnetic resonance imaging (13 male, age range: 8-18 years) and 14 age- and race-matched controls (7 male, age range: 10-19 years) to determine the extent of white matter injury. The hypotheses that white matter damage is related to daytime peripheral oxygen saturation and steady-state hemoglobin were tested. Fractional anisotropy was found to be significantly lower in patients in the subcortical white matter (corticospinal tract and cerebellum), whereas mean diffusivity and radial diffusivity were higher in patients in widespread areas. There was a significant negative relationship between radial diffusivity and oxygen saturation (Plevel negative relationship between radial diffusivity and hemoglobin (Pcell anemia, and provides for the first time direct evidence of a relationship between brain microstructure and markers of disease severity (eg, peripheral oxygen saturation and steady-state hemoglobin). This study suggests that diffusion tensor imaging metrics may serve as a biomarker for future trials of reducing hypoxic exposure. © 2015 American Heart Association, Inc.

  10. Agreement between arterial partial pressure of carbon dioxide and saturation of hemoglobin with oxygen values obtained by direct arterial blood measurements versus noninvasive methods in conscious healthy and ill foals.

    Science.gov (United States)

    Wong, David M; Alcott, Cody J; Wang, Chong; Bornkamp, Jennifer L; Young, Jessica L; Sponseller, Brett A

    2011-11-15

    To determine agreement between indirect measurements of end-tidal partial pressure of carbon dioxide (PetCO(2)) and saturation of hemoglobin with oxygen as measured by pulse oximetry (SpO(2)) with direct measurements of PaCO(2) and calculated saturation of hemoglobin with oxygen in arterial blood (SaO(2)) in conscious healthy and ill foals. Validation study. 10 healthy and 21 ill neonatal foals. Arterial blood gas analysis was performed on healthy and ill foals examined at a veterinary teaching hospital to determine direct measurements of PaCO(2) and PaO(2) along with SaO(2). Concurrently, PetCO(2) was measured with a capnograph inserted into a naris, and SpO(2) was measured with a reflectance probe placed at the base of the tail. Paired values were compared by use of Pearson correlation coefficients, and level of agreement was assessed with the Bland-Altman method. Mean ± SD difference between PaCO(2) and PetCO(2) was 0.1 ± 5.0 mm Hg. There was significant strong correlation (r = 0.779) and good agreement between PaCO(2) and PetCO(2). Mean ± SD difference between SaO(2) and SpO(2) was 2.5 ± 3.5%. There was significant moderate correlation (r = 0.499) and acceptable agreement between SaO(2) and SpO(2). Both PetCO(2) obtained by use of nasal capnography and SpO(2) obtained with a reflectance probe are clinically applicable and accurate indirect methods of estimating and monitoring PaCO(2) and SaO(2) in neonatal foals. Indirect methods should not replace periodic direct measurement of corresponding parameters.

  11. Intraoperative colonic pulse oximetry in left-sided colorectal surgery: can it predict anastomotic leak?

    Science.gov (United States)

    Salusjärvi, Johannes M; Carpelan-Holmström, Monika A; Louhimo, Johanna M; Kruuna, Olli; Scheinin, Tom M

    2018-03-01

    An anastomotic leak is a fairly common and a potentially lethal complication in colorectal surgery. Objective methods to assess the viability and blood circulation of the anastomosis could help in preventing leaks. Intraoperative pulse oximetry is a cheap, easy to use, fast, and readily available method to assess tissue viability. Our aim was to study whether intraoperative pulse oximetry can predict the development of an anastomotic leak. The study was a prospective single-arm study conducted between the years 2005 and 2011 in Helsinki University Hospital. Patient material consisted of 422 patients undergoing elective left-sided colorectal surgery. The patients were operated by one of the three surgeons. All of the operations were partial or total resections of the left side of the colon with a colorectal anastomosis. The intraoperative colonic oxygen saturation was measured with pulse oximetry from the colonic wall, and the values were analyzed with respect to post-operative complications. 2.3 times more operated anastomotic leaks occurred when the colonic StO 2 was ≤ 90% (11/129 vs 11/293). The mean colonic StO 2 was 91.1 in patients who developed an operated anastomotic leak and 93.0 in patients who did not. With logistic regression analysis, the risk of operated anastomotic leak was 4.2 times higher with StO 2 values ≤ 90%. Low intraoperative colonic StO 2 values are associated with the occurrence of anastomotic leak. Despite its handicaps, the method seems to be useful in assessing anastomotic viability.

  12. In-vitro model for evaluation of pulse oximetry

    Science.gov (United States)

    Vegfors, Magnus; Lindberg, Lars-Goeran; Lennmarken, Claes; Oberg, P. Ake

    1991-06-01

    An in vitro model with blood circulating in a silicon tubing system and including an artificial arterial bed is an important tool for evaluation of the pulse oximetry technique. The oxygen saturation was measured on an artificial finger using a pulse oximeter (SpO2) and on blood samples using a hemoximeter (SaO2). Measurements were performed at different blood flows and at different blood hematocrits. An increase in steady as well as in pulsatile blood flow was followed by an increase in pulse oximeter readings and a better agreement between SpO2 and SaO2 readings. After diluting the blood with normal saline (decreased hematocrit) the agreement was further improved. These results indicate that the pulse oximeter signal is related to blood hematocrit and the velocity of blood. The flow-related dependance of SpO2 was also evaluated in a human model. These results provided evidence that the pulse oximeter signal is dependent on vascular changes.

  13. Determination of blood volume by pulse CO-oximetry

    International Nuclear Information System (INIS)

    Lalande, S; Kelsey, J W; Joyner, M J; Johnson, B D

    2012-01-01

    The objective of this study was to determine whether changes in carboxyhaemoglobin (COHb) saturation following carbon monoxide (CO) rebreathing can be accurately detected by pulse CO-oximetry in order to determine blood volume. Noninvasive measurements of carboxyhaemoglobin saturation (SpCO) were continuously monitored by pulse CO-oximetry before, during and following 2 min of CO rebreathing. Reproducibility and accuracy of noninvasive blood volume measurements were determined in 16 healthy non-smoking individuals (15 males, age: 28 ± 2 years, body mass index: 25.4 ± 0.6 kg m −2 ) through comparison with blood volume measurements calculated from invasive measurements of COHb saturation. The coefficient of variation for noninvasive blood volume measurements performed on separate days was 15.1% which decreases to 9.1% when measurements were performed on the same day. Changes in COHb saturation and SpCO following CO rebreathing were strongly correlated (r = 0.90, p < 0.01), resulting in a significant correlation between invasive and noninvasive blood volume measurements (r = 0.83, p = 0.02). Changes in SpCO following CO rebreathing can be accurately detected by pulse CO-oximetry, which could potentially provide a simplified, convenient and reproducible method to rapidly determine blood volume in healthy individuals

  14. Correlation of results obtained by in-vivo optical spectroscopy with measured blood oxygen saturation using a positive linear regression fit

    Science.gov (United States)

    McCormick, Patrick W.; Lewis, Gary D.; Dujovny, Manuel; Ausman, James I.; Stewart, Mick; Widman, Ronald A.

    1992-05-01

    Near infrared light generated by specialized instrumentation was passed through artificially oxygenated human blood during simultaneous sampling by a co-oximeter. Characteristic absorption spectra were analyzed to calculate the ratio of oxygenated to reduced hemoglobin. A positive linear regression fit between diffuse transmission oximetry and measured blood oxygenation over the range 23% to 99% (r2 equals .98, p signal was observed in the patient over time. The procedure was able to be performed clinically without difficulty; rSO2 values recorded continuously demonstrate the usefulness of the technique. Using the same instrumentation, arterial input and cerebral response functions, generated by IV tracer bolus, were deconvoluted to measure mean cerebral transit time. Date collected over time provided a sensitive index of changes in cerebral blood flow as a result of therapeutic maneuvers.

  15. Noncontact simultaneous dual wavelength photoplethysmography: A further step toward noncontact pulse oximetry

    International Nuclear Information System (INIS)

    Humphreys, Kenneth; Ward, Tomas; Markham, Charles

    2007-01-01

    We present a camera-based device capable of capturing two photoplethysmographic (PPG) signals at two different wavelengths simultaneously, in a remote noncontact manner. The system comprises a complementary metal-oxide semiconductor camera and dual wavelength array of light emitting diodes (760 and 880 nm). By alternately illuminating a region of tissue with each wavelength of light, and detecting the backscattered photons with the camera at a rate of 16 frames/wavelength s, two multiplexed PPG wave forms are simultaneously captured. This process is the basis of pulse oximetry, and we describe how, with the inclusion of a calibration procedure, this system could be used as a noncontact pulse oximeter to measure arterial oxygen saturation (S p O 2 ) remotely. Results from an experiment on ten subjects, exhibiting normal S p O 2 readings, that demonstrate the instrument's ability to capture signals from a range of subjects under realistic lighting and environmental conditions are presented. We compare the signals captured by the noncontact system to a conventional PPG signal captured concurrently from a finger, and show by means of a J. Bland and D. Altman [Lancet 327, 307 (1986); Statistician 32, 307 (1983)] test, the noncontact device to be comparable to a contact device as a monitor of heart rate. We highlight some considerations that should be made when using camera-based ''integrative'' sampling methods and demonstrate through simulation, the suitability of the captured PPG signals for application of existing pulse oximetry calibration procedures

  16. Noncontact simultaneous dual wavelength photoplethysmography: A further step toward noncontact pulse oximetry

    Science.gov (United States)

    Humphreys, Kenneth; Ward, Tomas; Markham, Charles

    2007-04-01

    We present a camera-based device capable of capturing two photoplethysmographic (PPG) signals at two different wavelengths simultaneously, in a remote noncontact manner. The system comprises a complementary metal-oxide semiconductor camera and dual wavelength array of light emitting diodes (760 and 880nm). By alternately illuminating a region of tissue with each wavelength of light, and detecting the backscattered photons with the camera at a rate of 16frames/wavelengths, two multiplexed PPG wave forms are simultaneously captured. This process is the basis of pulse oximetry, and we describe how, with the inclusion of a calibration procedure, this system could be used as a noncontact pulse oximeter to measure arterial oxygen saturation (SpO2) remotely. Results from an experiment on ten subjects, exhibiting normal SpO2 readings, that demonstrate the instrument's ability to capture signals from a range of subjects under realistic lighting and environmental conditions are presented. We compare the signals captured by the noncontact system to a conventional PPG signal captured concurrently from a finger, and show by means of a J. Bland and D. Altman [Lancet 327, 307 (1986); Statistician 32, 307 (1983)] test, the noncontact device to be comparable to a contact device as a monitor of heart rate. We highlight some considerations that should be made when using camera-based "integrative" sampling methods and demonstrate through simulation, the suitability of the captured PPG signals for application of existing pulse oximetry calibration procedures.

  17. Retinopathy of prematurity and induced changes in arterial oxygen saturation with near infrared spectrophotometry: a retrospective cohort study

    Science.gov (United States)

    von Siebenthal, K.; Keel, M.; Dietz, V.; Fauchere, J. C.; Martin, X.; Wolf, Martin; Duc, G.; Bucher, H. U.

    1996-10-01

    Near-infrared spectrophotometry (NIRS) is a noninvasive method for measuring oxygenated and deoxygenated hemoglobin in the neonatal brain. Using oxygen as a tracer, it is possible to calculate cerebral blood flow (cbf) and hemoglobin concentration (cHbc), which corresponds to cerebral blood volume, by inducing small changes in arterial oxygen saturation. Variability of tcpO2 is considered to be associated with severe retinopathy of prematurity (ROP). A preliminary analysis without control found a 51 percent incidence of ROP in infants subjected to NIRS measurements whereas among infants who were not exposed to oxygen changes, only 29 percent developed ROP. A controlled study with matched pairs was performed. Thirty-nine premature newborns who had received NIRS recordings were matched with 39 out of 172 infants who had not received NIRS. Using this controlled study design there was no difference in the incidence and severity of ROP between the two groups. The conclusions are that: 1) small changes in oxygen saturation of 3 to 10 percent to measure cbf and cHbc did not increase the incidence or the degree of severity of ROP. 2) A controlled study design is important. Analyses of uncontrolled data would have led to the conclusion that oxygen changes as used with NIRS increase the risk of ROP.

  18. Photoacoustic measurements of red blood cell oxygen saturation in blood bags in situ

    Science.gov (United States)

    Pinto, Ruben N.; Bagga, Karan; Douplik, Alexandre; Acker, Jason P.; Kolios, Michael C.

    2017-03-01

    Red blood cell (RBC) transfusion is a critical component of the health care services. RBCs are stored in blood bags in hypothermic temperatures for a maximum of 6 weeks post donation. During this in vitro storage period, RBCs have been documented to undergo changes in structure and function due to mechanical and biochemical stress. Currently, there are no assessment methods that monitor the quality of RBCs within blood bags stored for transfusion. Conventional assessment methods require the extraction of samples, consequently voiding the sterility of the blood bags and potentially rendering them unfit for transfusions. It is hypothesized that photoacoustic (PA) technology can provide a rapid and non-invasive indication of RBC quality. In this study, a novel PA setup was developed for the acquisition of oxygen saturation (SO2) of two blood bags in situ. These measurements were taken throughout the lifespan of the blood bags (42 days) and compared against the clinical gold standard method of the blood gas analyzer (BGA). SO2 values of the blood bags increased monotonically throughout the storage period. A strong correlation between PA SO2 and BGA SO2 was found, however, PA values were on average 3.5% lower. Both techniques found the bags to increase by an SO2 of approximately 20%, and measured very similar rates of SO2 change. Future work will be focused on determining the cause of discrepancy between SO2 values acquired from PA versus BGA, as well as establishing links between the measured SO2 increase and other changes in RBC in situ.

  19. Effects of salmeterol on sleeping oxygen saturation in chronic obstructive pulmonary disease.

    LENUS (Irish Health Repository)

    Ryan, Silke

    2012-02-01

    BACKGROUND: Sleep is associated with important adverse effects in patients with chronic obstructive pulmonary disease (COPD), such as disturbed sleep quality and gas exchange, including hypoxemia and hypercapnia. The effects of inhaled long-acting beta(2)-agonist therapy (LABA) on these disturbances are unclear. OBJECTIVES: The aim of the study was to assess the effect of inhaled salmeterol on nocturnal sleeping arterial oxygen saturation (SaO(2)) and sleep quality. METHODS: In a randomized, double-blind, placebo-controlled, crossover study of moderate\\/severe stable COPD patients, we compared the effects of 4 weeks of treatment with salmeterol 50 microg b.d. and matching placebo on sleeping SaO(2) and sleep quality. Overnight polysomnography (PSG) was performed at baseline, and after 4 and 8 weeks in addition to detailed pulmonary function testing. Of 15 patients included, 12 completed the trial (median age 69 years, forced expiratory volume in 1 s, FEV(1): 39%). RESULTS: Both mean SaO(2) [salmeterol vs. placebo: 92.9% (91.2, 94.7) vs. 91.0% (88.9, 94.8); p = 0.016] and the percentage of sleep spent below 90% of SaO(2) [1.8% (0.0, 10.8) vs. 25.6% (0.5, 53.5); p = 0.005] improved significantly with salmeterol. Sleep quality was similar with both salmeterol and placebo on PSG. Static lung volumes, particularly trapped gas volume, tended to improve with salmeterol. CONCLUSION: We conclude that inhaled LABA therapy improves sleeping SaO(2) without significant change in sleep quality.

  20. Intra-dialytic blood oxygen saturation (SO2): association with dialysis hypotension (the SOGLIA Study).

    Science.gov (United States)

    Mancini, E; Perazzini, C; Gesualdo, L; Aucella, F; Limido, A; Scolari, F; Savoldi, S; Tramonti, M; Corazza, L; Atti, M; Severi, S; Bolasco, P; Santoro, A

    2017-12-01

    Intradialytic hypotension (IDH) has a dramatic impact on the main outcomes of dialysis patients. Early warning of hemodynamic worsening during dialysis would enable preventive measures to be taken. Blood oxygen saturation (SO 2 ) is used for hemodynamic monitoring in the critical care setting and may provide useful information about IDH onset. To evaluate whether short- and medium-term variations in the SO 2 signal (ST-SO 2var , MT-SO 2var ,) during dialysis are a predictor of IDH. In this 3-month observational cohort study, 51 hypotension-prone chronic hemodialysis (HD) patients, with vascular access by arteriovenous fistula (AVF) or central venous catheter (CVC), were enrolled. Continuous non-invasive blood SO 2 was monitored (fc = 0.2 Hz) by an optical sensor on the arterial line of the extracorporeal circulation; blood pressure (every 30 min), symptoms and their time of appearance were noted. Predictive power of IDH was expressed by the area under curve (AUC) sensitivity and specificity based on intradialytic variations in SO 2 . A total of 1290 HD sessions were analyzed. Overall, off-line ST-SO 2var analysis proved able to correctly predict IDH in 67 % of the sessions where IDH occurred. The best predictive performance was found in the presence of highly arterialized AVF (SO 2  > 95 %) (75 % sensitivity; AUC 0.825; p < 0.05). On the contrary, in sessions with CVC, IDH prediction proved more efficient by MT-SO 2var (AUC 0.575; p = 0.01). Intradialytic SO 2 variability could be a valid parameter to detect in advance the hemodynamic worsening that precedes IDH. Appropriate timely intervention could help prevent IDH onset.

  1. High-affinity hemoglobin and blood oxygen saturation in diving emperor penguins.

    Science.gov (United States)

    Meir, Jessica U; Ponganis, Paul J

    2009-10-01

    The emperor penguin (Aptenodytes forsteri) thrives in the Antarctic underwater environment, diving to depths greater than 500 m and for durations longer than 23 min. To examine mechanisms underlying the exceptional diving ability of this species and further describe blood oxygen (O2) transport and depletion while diving, we characterized the O2-hemoglobin (Hb) dissociation curve of the emperor penguin in whole blood. This allowed us to (1) investigate the biochemical adaptation of Hb in this species, and (2) address blood O2 depletion during diving, by applying the dissociation curve to previously collected partial pressure of O2 (PO2) profiles to estimate in vivo Hb saturation (SO2) changes during dives. This investigation revealed enhanced Hb-O2 affinity (P50=28 mmHg, pH 7.5) in the emperor penguin, similar to high-altitude birds and other penguin species. This allows for increased O2 at low blood PO2 levels during diving and more complete depletion of the respiratory O2 store. SO2 profiles during diving demonstrated that arterial SO2 levels are maintained near 100% throughout much of the dive, not decreasing significantly until the final ascent phase. End-of-dive venous SO2 values were widely distributed and optimization of the venous blood O2 store resulted from arterialization and near complete depletion of venous blood O2 during longer dives. The estimated contribution of the blood O2 store to diving metabolic rate was low and highly variable. This pattern is due, in part, to the influx of O2 from the lungs into the blood during diving, and variable rates of tissue O2 uptake.

  2. Dual-wavelength photothermal optical coherence tomography for blood oxygen saturation measurement

    Science.gov (United States)

    Yin, Biwei; Kuranov, Roman V.; McElroy, Austin B.; Milner, Thomas E.

    2013-03-01

    We report design and demonstration of a dual wavelength photothermal (DWP) optical coherence tomography (OCT) system for imaging of a phantom microvessel and measurement of hemoglobin oxygen saturation (SO2) level. The DWP-OCT system contains a swept-source (SS) two-beam phase-sensitive (PhS) OCT system (1060 nm) and two intensity modulated photothermal excitation lasers (770 nm and 800 nm). The PhS-OCT probe beam (1060 nm) and photothermal excitation beams are combined into one single-mode optical fiber. A galvanometer based two-dimensional achromatic scanning system is designed to provide 14 μm lateral resolution for the PhS-OCT probe beam (1060 nm) and 13 μm lateral resolution for photothermal excitation beams. DWP-OCT system's sensitivity is 102 dB, axial resolution is 13 μm in tissue and uses a real-time digital dispersion compensation algorithm. Noise floor for optical pathlength measurements is 300 pm in the signal frequency range (380-400 Hz) of photothermal modulation frequencies. Blood SO2 level is calculated from measured optical pathlength (op) signal in a 300 μm diameter microvessel phantom introduced by the two photothermal excitation beams. En-face and B-scan images of a phantom microvessel are recorded, and six blood samples' SO2 levels are measured using DWP-OCT and compared with values provided by a commercial blood oximeter. A mathematical model indicates thermal diffusion introduces a systematic artifact that over-estimates SO2 values and is consistent with measured data.

  3. Effect of bupivacaine and adjuvant drugs for regional anesthesia on nerve tissue oximetry and nerve blood flow

    Directory of Open Access Journals (Sweden)

    Wiesmann T

    2018-01-01

    Full Text Available Thomas Wiesmann,1 Stefan Müller,1,2 Hans-Helge Müller,3 Hinnerk Wulf,1 Thorsten Steinfeldt1,4 1Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine, University Hospital Marburg, Philipps University, Marburg, 2Department of Anesthesiology and Intensive Care Medicine, University Hospital Giessen, Justus-Liebig-University, Giessen, 3Institute of Medical Biometry and Epidemiology, Philipps University, Marburg, 4Department of Anesthesiology and Intensive Care Medicine, Diakoniekrankenhaus Schwäbisch Hall, Schwäbisch Hall, Germany Background: Nerve blood flow has a critical role in acute and chronic pathologies in peripheral nerves. Influences of local anesthetics and adjuvants on tissue perfusion and oxygenation are deemed as relevant factors for nerve damage after peripheral regional anesthesia. The link between low tissue perfusion due to local anesthetics and resulting tissue oxygenation is unclear.Methods: Combined tissue spectrophotometry and laser-Doppler flowmetry were used to assess nerve blood flow in 40 surgically exposed median nerves in pigs, as well as nerve tissue oximetry for 60 min. After baseline measurements, test solutions saline (S, bupivacaine (Bupi, bupivacaine with epinephrine (BupiEpi, and bupivacaine with clonidine (BupiCloni were applied topically.Results: Bupivacaine resulted in significant decrease in nerve blood flow, as well as tissue oximetry values, compared with saline control. Addition of epinephrine resulted in a rapid, but nonsignificant, reduction of nerve blood flow and extensive lowering of tissue oximetry levels. The use of clonidine resulted in a reduction of nerve blood flow, comparable to bupivacaine alone (relative blood flow at T60 min compared with baseline, S: 0.86 (0.67–1.18, median (25th–75th percentile; Bupi: 0.33 (0.25–0.60; BupiCloni: 0.43 (0.38–0.63; and BupiEpi: 0.41(0.30–0.54. The use of adjuvants did not result in any relevant impairment of tissue oximetry

  4. Advances in Probes and Methods for Clinical EPR Oximetry

    Science.gov (United States)

    Hou, Huagang; Khan, Nadeem; Jarvis, Lesley A.; Chen, Eunice Y.; Williams, Benjamin B.; Kuppusamy, Periannan

    2015-01-01

    EPR oximetry, which enables reliable, accurate, and repeated measurements of the partial pressure of oxygen in tissues, provides a unique opportunity to investigate the role of oxygen in the pathogenesis and treatment of several diseases including cancer, stroke, and heart failure. Building on significant advances in the in vivo application of EPR oximetry for small animal models of disease, we are developing suitable probes and instrumentation required for use in human subjects. Our laboratory has established the feasibility of clinical EPR oximetry in cancer patients using India ink, the only material presently approved for clinical use. We now are developing the next generation of probes, which are both superior in terms of oxygen sensitivity and biocompatibility including an excellent safety profile for use in humans. Further advances include the development of implantable oxygen sensors linked to an external coupling loop for measurements of deep-tissue oxygenations at any depth, overcoming the current limitation of 10 mm. This paper presents an overview of recent developments in our ability to make meaningful measurements of oxygen partial pressures in human subjects under clinical settings. PMID:24729217

  5. Finger blood content, light transmission, and pulse oximetry errors.

    Science.gov (United States)

    Craft, T M; Lawson, R A; Young, J D

    1992-01-01

    The changes in light emitting diode current necessary to maintain a constant level of light incident upon a photodetector were measured in 20 volunteers at the two wavelengths employed by pulse oximeters. Three states of finger blood content were assessed; exsanguinated, hyperaemic, and normal. The changes in light emitting diode current with changes in finger blood content were small and are not thought to represent a significant source of error in saturation as measured by pulse oximetry.

  6. An in vivo evaluation of the change in the pulpal oxygen saturation after administration of preoperative anxiolytics and local anesthesia

    Directory of Open Access Journals (Sweden)

    Krishna P. Shetty

    2016-03-01

    Full Text Available Background. Given the influence of systemic blood pressure on pulpal blood flow, anxiolytics prescribed may alter the pulpal blood flow along with the local anesthetic solution containing a vasoconstrictor. This study evaluated the impact of preoperative anxiolytics and vasoconstrictors in local anesthetic agents on pulpal oxygen saturation. Methods. Thirty anxious young healthy individuals with a mean age of 24 years were randomly selected using the Corah’s Dental Anxiety Scale (DAS. After checking the vital signs the initial pulpal oxygen saturation (initial SpO2 was measured using a pulse oximeter. Oral midzolam was administered at a dose of 7.5 mg. After 30 min, the vital signs were monitored and the pulpal oxygen saturation (anxiolytic SpO2 was measured. A total of 1.5 mL of 2% lidocaine with 1:200000 epinephrine was administered as buccal infiltration anesthesia and 10 min the final pulpal oxygen saturation (L.A SpO2 was measured. Results. The mean initial (SpO2 was 96.37% which significantly decreased to 90.76% (SpO2 after the administration of the anxiolytic agent. This drop was later accentuated to 85.17% (SpO2 after administration of local anesthetic solution. Statistical significance was set at P<0.0001. Conclusion. High concentrations of irritants may permeate dentin due to a considerable decrease in the pulpal blood flow from crown or cavity preparation. Therefore, maintaining optimal blood flow during restorative procedures may prevent pulpal injury.

  7. EFFECTIVENESS OF AUTOGENIC DRAINAGE VERSUS POSTURAL DRAINAGE ON OXYGEN SATURATION IN PATIENTS WITH CHRONIC BRONCHITIS WITH 15 MINUTES POST THERAPY

    OpenAIRE

    V. Kiran; Dr. Bhimasen .S; E. Mastanaiah; A. Thiruppathi

    2014-01-01

    Background: Patients with COPD will have more amount of secretions. To clear the secretions by using of different bronchial hygiene techniques like postural drainage and autogenic drainage technique, manual hyperventilation technique ,active cycle breathing technique .Hence in this study to compare the short-term effects of postural drainage with clapping (PD) and autogenic drainage (AD) on level of oxygen saturation in blood, and amount of sputum recovery. Methodology: The study was done ...

  8. A comparison of oxygen saturation measurements obtained from a 'blue sensor' with a standard sensor.

    Science.gov (United States)

    Mawson, Isabel E; Dawson, Jennifer A; Donath, Susan M; Davis, Peter G

    2011-10-01

    The study aims to investigate pulse oximetry measurements from a 'blue' pulse oximeter sensor against measurements from a 'standard' pulse oximeter sensor in newly born infants. Immediately after birth, both sensors were attached to the infant, one to each foot. SpO₂ measurements were recorded simultaneously from each sensor for 10 min. Agreement between pairs of SpO₂ measurements were calculated using Bland-Altman analysis. Thirty-one infants were studied. There was good correlation between simultaneous SpO₂ measurements from both sensors (r² = 0.75). However, the mean difference between 'blue' and 'standard' sensors was -1.6%, with wide 95% limits of agreement +18.4 to -21.6%. The range of mean difference between sensors from each infant ranged from -20 to +20. The mean difference between the blue and standard sensor SpO₂ measurements is not clinically important. © 2011 The Authors. Journal of Paediatrics and Child Health © 2011 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  9. Angiotensin-converting enzyme genotype and arterial oxygen saturation at high altitude in Peruvian Quechua.

    Science.gov (United States)

    Bigham, Abigail W; Kiyamu, Melisa; León-Velarde, Fabiola; Parra, Esteban J; Rivera-Ch, Maria; Shriver, Mark D; Brutsaert, Tom D

    2008-01-01

    The I-allele of the angiotensin-converting enzyme (ACE) gene insertion/deletion (I/D) polymorphism has been associated with performance benefits at high altitude (HA). In n = 142 young males and females of largely Quechua origins in Peru, we evaluated 3 specific hypotheses with regard to the HA benefits of the I-allele: (1) the I-allele is associated with higher arterial oxygen saturation (Sa(O(2))) at HA, (2) the I-allele effect depends on the acclimatization state of the subjects, and (3) the putative I-allele effect on Sa(O(2)) is mediated by the isocapnic hypoxic ventilatory response (HVR, l/min(1)/% Sa(O(2))(1)). The subject participants comprised two different study groups including BLA subjects (born at low altitude) who were lifelong sea-level residents transiently exposed to hypobaric hypoxia (<24 h) and BHA subjects (born at HA) who were lifelong residents of HA. To control for the possibility of population stratification, Native American ancestry proportion (NAAP) was estimated as a covariate for each individual using a panel of 70 ancestry-informative molecular markers (AIMS). At HA, resting and exercise Sa(O(2)) was strongly associated with the ACE genotype, p = 0.008 with approximately 4% of the total variance in Sa(O(2)) attributed to ACE genotype. Moreover, I/I individuals maintained approximately 2.3 percentage point higher Sa(O(2)) compared to I/D and D/D. This I-allele effect was evident in both BLA and BHA groups, suggesting that acclimatization state has little influence on the phenotypic expression of the ACE gene. Finally, ACE genotype was not associated with the isocapnic HVR, although HVR had a strong independent effect on Sa(O(2)) (p = 0.001). This suggests that the I-allele effect on Sa(O(2)) is not mediated by the peripheral control of breathing, but rather by some other central cardiopulmonary effect of the ACE gene on the renin-angiotensin-aldosterone system (RAAS).

  10. Prognostic value of brachioradialis muscle oxygen saturation index and vascular occlusion test in septic shock patients.

    Science.gov (United States)

    Marín-Corral, J; Claverias, L; Bodí, M; Pascual, S; Dubin, A; Gea, J; Rodriguez, A

    2016-05-01

    To compare rSO2 (muscle oxygen saturation index) static and dynamic variables obtained by NIRS (Near Infrared Spectroscopy) in brachioradialis muscle of septic shock patients and its prognostic implications. Prospective and observational study. Intensive care unit. Septic shock patients and healthy volunteers. The probe of a NIRS device (INVOS 5100) was placed on the brachioradialis muscle during a vascular occlusion test (VOT). Baseline, minimum and maximum rSO2 values, deoxygenation rate (DeOx), reoxygenation slope (ReOx) and delta value. Septic shock patients (n=35) had lower baseline rSO2 (63.8±12.2 vs. 69.3±3.3%, p<0.05), slower DeOx (-0.54±0.31 vs. -0.91±0.35%/s, p=0.001), slower ReOx (2.67±2.17 vs. 9.46±3.5%/s, p<0.001) and lower delta (3.25±5.71 vs. 15.1±3.9%, p<0.001) when compared to healthy subjects (n=20). Among septic shock patients, non-survivors showed lower baseline rSO2 (57.0±9.6 vs. 69.8±11.3%, p=0.001), lower minimum rSO2 (36.0±12.8 vs. 51.3±14.8%, p<0.01) and lower maximum rSO2 values (60.6±10.6 vs. 73.3±11.2%, p<0.01). Baseline rSO2 was a good mortality predictor (AUC 0.79; 95%CI: 0.63-0.94, p<0.01). Dynamic parameters obtained with VOT did not improve the results. Septic shock patients present an important alteration of microcirculation that can be evaluated by NIRS with prognostic implications. Monitoring microvascular reactivity in the brachioradialis muscle using VOT with our device does not seem to improve the prognostic value of baseline rSO2. Copyright © 2015 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  11. Pulse oximetry for perioperative monitoring

    DEFF Research Database (Denmark)

    Pedersen, Tom; Nicholson, Amanda; Hovhannisyan, Karen

    2014-01-01

    or infectious complications were detected in the two groups. The duration of hospital stay was a median of five days in both groups, and equal numbers of in-hospital deaths were reported in the two groups. Continuous pulse oximetry has the potential to increase vigilance and decrease pulmonary complications...

  12. [Monitorization of the effects of spinal anaesthesia on cerebral oxygen saturation in elder patients using near-infrared spectroscopy].

    Science.gov (United States)

    Kusku, Aysegul; Demir, Guray; Cukurova, Zafer; Eren, Gulay; Hergunsel, Oya

    2014-01-01

    Central blockage provided by spinal anaesthesia enables realization of many surgical procedures, whereas hemodynamic and respiratory changes influence systemic oxygen delivery leading to the potential development of series of problems such as cerebral ischemia, myocardial infarction and acute renal failure. This study was intended to detect potentially adverse effects of hemodynamic and respiratory changes on systemic oxygen delivery using cerebral oxymetric methods in patients who underwent spinal anaesthesia. Twenty-five ASA I-II Group patients aged 65-80 years scheduled for unilateral inguinal hernia repair under spinal anaesthesia were included in the study. Following standard monitorization baseline cerebral oxygen levels were measured using cerebral oximetric methods. Standardized Mini Mental Test (SMMT) was applied before and after the operation so as to determine the level of cognitive functioning of the cases. Using a standard technique and equal amounts of a local anaesthetic drug (15mg bupivacaine 5%) intratechal blockade was performed. Mean blood pressure (MBP), maximum heart rate (MHR), peripheral oxygen saturation (SpO2) and cerebral oxygen levels (rSO2) were preoperatively monitored for 60min. Pre- and postoperative haemoglobin levels were measured. The variations in data obtained and their correlations with the cerebral oxygen levels were investigated. Significant changes in pre- and postoperative measurements of haemoglobin levels and SMMT scores and intraoperative SpO2 levels were not observed. However, significant variations were observed in intraoperative MBP, MHR and rSO2 levels. Besides, a correlation between variations in rSO2, MBP and MHR was determined. Evaluation of the data obtained in the study demonstrated that post-spinal decline in blood pressure and also heart rate decreases systemic oxygen delivery and adversely effects cerebral oxygen levels. However, this downward change did not result in deterioration of cognitive functioning

  13. Monitorization of the effects of spinal anaesthesia on cerebral oxygen saturation in elder patients using near-infrared spectroscopy.

    Science.gov (United States)

    Kusku, Aysegul; Demir, Guray; Cukurova, Zafer; Eren, Gulay; Hergunsel, Oya

    2014-01-01

    Central blockage provided by spinal anaesthesia enables realization of many surgical procedures, whereas hemodynamic and respiratory changes influence systemic oxygen delivery leading to the potential development of series of problems such as cerebral ischemia, myocardial infarction and acute renal failure. This study was intended to detect potentially adverse effects of hemodynamic and respiratory changes on systemic oxygen delivery using cerebral oxymetric methods in patients who underwent spinal anaesthesia. Twenty-five ASA I-II Group patients aged 65-80 years scheduled for unilateral inguinal hernia repair under spinal anaesthesia were included in the study. Following standard monitorization baseline cerebral oxygen levels were measured using cerebral oximetric methods. Standardized Mini Mental Test (SMMT) was applied before and after the operation so as to determine the level of cognitive functioning of the cases. Using a standard technique and equal amounts of a local anaesthetic drug (15mg bupivacaine 5%) intratechal blockade was performed. Mean blood pressure (MBP), maximum heart rate (MHR), peripheral oxygen saturation (SpO2) and cerebral oxygen levels (rSO2) were preoperatively monitored for 60min. Pre- and postoperative haemoglobin levels were measured. The variations in data obtained and their correlations with the cerebral oxygen levels were investigated. Significant changes in pre- and postoperative measurements of haemoglobin levels and SMMT scores and intraoperative SpO2 levels were not observed. However, significant variations were observed in intraoperative MBP, MHR and rSO2 levels. Besides, a correlation between variations in rSO2, MBP and MHR was determined. Evaluation of the data obtained in the study demonstrated that post-spinal decline in blood pressure and also heart rate decreases systemic oxygen delivery and adversely effects cerebral oxygen levels. However, this downward change did not result in deterioration of cognitive functioning

  14. Growth of the microalgae Neochloris oleoabundans at high partial oxygen pressures and sub-saturating light intensity.

    Science.gov (United States)

    Sousa, Cláudia; de Winter, Lenneke; Janssen, Marcel; Vermuë, Marian H; Wijffels, René H

    2012-01-01

    The effect of partial oxygen pressure on growth of Neochloris oleoabundans was studied at sub-saturating light intensity in a fully-controlled stirred tank photobioreactor. At the three partial oxygen pressures tested (P(O)₂= 0.24; 0.63; 0.84 bar), the specific growth rate was 1.38; 1.36 and 1.06 day(-1), respectively. An increase of the P(CO)₂from 0.007 to 0.02 bar at P(O₂) of 0.84 bar resulted in an increase in the growth rate from 1.06 to 1.36 day(-1). These results confirm that the reduction of algal growth at high oxygen concentrations at sub-saturating light conditions is mainly caused by competitive inhibition of Rubisco. This negative effect on growth can be overcome by restoring the O(2)/CO(2) ratio by an increase in the partial carbon dioxide pressure. In comparison to general practice (P(O(2)) = 0.42 bar), working at partial O(2) pressure of 0.84 bar could reduce the energy requirement for degassing by a factor of 3-4. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test.

    Science.gov (United States)

    Steenhaut, Kevin; Lapage, Koen; Bové, Thierry; De Hert, Stefan; Moerman, Annelies

    2017-12-01

    An increasing number of NIRS devices are used to provide measurements of peripheral tissue oxygen saturation (S t O 2 ). The aim of the present study is to test the hypothesis that despite technological differences between devices, similar trend values will be obtained during a vascular occlusion test. The devices compared are NIRO-200NX, which measures S t O 2 and oxyhemoglobin by spatially resolved spectroscopy and the Beer-Lambert law, respectively, and INVOS 5100C and Foresight Elite, which both measure S t O 2 with the Beer-Lambert law, enhanced with the spatial resolution technique. Forty consenting adults scheduled for CABG surgery were recruited. The respective sensors of the three NIRS devices were applied over the brachioradial muscle. Before induction of anesthesia, 3 min of ischemia were induced by inflating a blood pressure cuff at the upper arm, whereafter cuff pressure was rapidly released. Tissue oxygenation measurements included baseline, minimum and maximum values, desaturation and resaturation slopes, and rise time. Comparisons between devices were performed with the Kruskal-Wallis test with post hoc Mann-Whitney pairwise comparisons. Agreement was evaluated using Bland-Altman plots. Oxyhemoglobin measured with NIRO responded faster than the other NIRS technologies to changes in peripheral tissue oxygenation (20 vs. 27-40 s, p ≤ 0.01). When comparing INVOS with Foresight, oxygenation changes were prompter (upslope 311 [92-523]%/min vs. 114[65-199]%/min, p ≤ 0.01) and more pronounced (minimum value 36 [21-48] vs. 45 [40-51]%, p ≤ 0.01) with INVOS. Significant differences in tissue oxygen saturation measurements were observed, both within the same device as between different devices using the same measurement technology.

  16. Do dental procedures affect lung function and arterial oxygen saturation in asthmatic patients?

    Directory of Open Access Journals (Sweden)

    Magdy Mahmoud Emara

    2013-04-01

    Conclusion: Asthmatic patients may be at a higher risk of developing oxygen desaturation after dental procedures regardless of their type with and without local anesthesia and a decrease in PEF after dental procedures with local anesthesia.

  17. Detection of Hb Rothschild HBB: c.[112T>A or 112T>C], Through High Index of Suspicion on Abnormal Pulse Oximetry.

    Science.gov (United States)

    Alli, Nazeer A; Wessels, Piet; Rampersad, Narisha; Clark, Barnaby E; Thein, Swee Lay

    2017-03-01

    We describe a case with a low oxygen affinity hemoglobin (Hb) variant who presented with cyanosis in the absence of cardiopulmonary disease. The patient, a 27-year-old pregnant female (P1G2), complained of a productive cough and bluish discoloration of the lips that started 3 days prior to seeking attention. She had no previous episodes and has generally been in good health. A positive family history of cyanosis was obtained in one sibling. Systematic examination, notably the cardiorespiratory system, revealed no abnormalities. The arterial Hb oxygen saturation (SpO 2 ) on pulse oximetry was 81.0% and Hb separation studies revealed an Hb variant identified as Hb Rothschild [β37(C3)Trp→Arg] (HBB: c.[112 T>A or 112 T>C]) by gene sequencing. The amino acid substitution (Trp→Arg) is an important contact point at the α1β2 interface and favors a T-quaternary state of the Hb tetramer. This leads to a low oxygen affinity state, which results in premature release of oxygen and drop in oxygen saturation. In the absence of cardiopulmonary disease, a decreased oxygen saturation reading, with or without cyanosis, should arouse suspicion for a possible dysHb.

  18. Peripheral tissue oximetry

    DEFF Research Database (Denmark)

    Hyttel-Sorensen, Simon; Hessel, Trine Witzner; Greisen, Gorm

    2014-01-01

    Estimation of regional tissue oxygenation (rStO2) by near infrared spectroscopy enables non-invasive end-organ oxygen balance monitoring and could be a valuable tool in intensive care. However, the diverse absolute values and dynamics of different devices, and overall poor repeatability of measur......Estimation of regional tissue oxygenation (rStO2) by near infrared spectroscopy enables non-invasive end-organ oxygen balance monitoring and could be a valuable tool in intensive care. However, the diverse absolute values and dynamics of different devices, and overall poor repeatability......, and response to changing oxygenation by the down slope of rStO2 during vascular occlusion in the respective arm. 10 healthy adults, 21-29 years old, with double skinfolds on the forearm less than 10 mm participated. The median rStO2 was 70.7% (interquartile range (IQR) 7.7%), 68.4% (IQR 8.4%), and 64.6% (IQR 4...

  19. Skeletal Muscle Oxygen Saturation (StO2 Measured by Near-Infrared Spectroscopy in the Critically Ill Patients

    Directory of Open Access Journals (Sweden)

    J. Mesquida

    2013-01-01

    Full Text Available According to current critical care management guidelines, the overall hemodynamic optimization process seeks to restore macrocirculatory oxygenation, pressure, and flow variables. However, there is increasing evidence demonstrating that, despite normalization of these global parameters, microcirculatory and regional perfusion alterations might occur, and persistence of these alterations has been associated with worse prognosis. Such observations have led to great interest in testing new technologies capable of evaluating the microcirculation. Near-infrared spectroscopy (NIRS measures tissue oxygen saturation (StO2 and has been proposed as a noninvasive system for monitoring regional circulation. The present review aims to summarize the existing evidence on NIRS and its potential clinical utility in different scenarios of critically ill patients.

  20. Assessment of the oxygen consumption in the backfill. Geochemical modelling in a saturated backfill

    International Nuclear Information System (INIS)

    Grandia, Fidel; Domenech, Cristina; Arcos, David; Duro, Lara

    2006-11-01

    The consumption of oxygen in the deep disposal is a major concern due to the ability of this element to corrode the canisters where high level nuclear wastes (HLNW) are disposed. The anoxic conditions initially present in a deep geologic environment are disturbed by the excavation of the repository facilities. After sealing the deposition holes and tunnels using clay-based materials, oxygen remains dissolved in porewater or as a gas phase in the unsaturated pores. The main mechanisms of oxygen depletion that can be considered in the backfill materials are: (1) diffusion into the surrounding rock and (2) kinetic reactions with accessory minerals and organic matter existing in the backfill. In this report, a set of numerical simulations are carried out in one and two dimensions in order to test the effect on the oxygen concentration in the pore water of all these mechanisms. The backfill considered is a 0/70 mixture of MX-80 bentonite and crushed material from the excavation itself. In addition to organic matter, the solid phases with reducing capacity in the backfill are Fe(II)-bearing minerals: pyrite (FeS 2 ) and siderite (FeCO) (as accessory minerals in the bentonite) and Fe-biotite (from the crushed granite). In the simulations, other chemical processes like cation exchange and surface complexation onto clay surfaces, and thermodynamic equilibrium with calcite, gypsum and quartz are considered. Initial composition of porewater is obtained by equilibrating the Forsmark groundwater with the backfill material. The 1D simulation consists of a number of cells with no reactive minerals or organic matter representing granite. The central cell, however, contains oxygen and reactive minerals resembling a backfill. Oxygen is allowed to move only by diffusion. The 2D model simulates the interaction with a backfill of a granitic groundwater flowing through a fracture. Like in the 1D model, the backfill contains oxygen and reactive solids. The results are very similar in

  1. Assessment of the oxygen consumption in the backfill. Geochemical modelling in a saturated backfill

    Energy Technology Data Exchange (ETDEWEB)

    Grandia, Fidel; Domenech, Cristina; Arcos, David; Duro, Lara [Enviros Spain S.L., Barcelona (Spain)

    2006-11-15

    The consumption of oxygen in the deep disposal is a major concern due to the ability of this element to corrode the canisters where high level nuclear wastes (HLNW) are disposed. The anoxic conditions initially present in a deep geologic environment are disturbed by the excavation of the repository facilities. After sealing the deposition holes and tunnels using clay-based materials, oxygen remains dissolved in porewater or as a gas phase in the unsaturated pores. The main mechanisms of oxygen depletion that can be considered in the backfill materials are: (1) diffusion into the surrounding rock and (2) kinetic reactions with accessory minerals and organic matter existing in the backfill. In this report, a set of numerical simulations are carried out in one and two dimensions in order to test the effect on the oxygen concentration in the pore water of all these mechanisms. The backfill considered is a 0/70 mixture of MX-80 bentonite and crushed material from the excavation itself. In addition to organic matter, the solid phases with reducing capacity in the backfill are Fe(II)-bearing minerals: pyrite (FeS{sub 2}) and siderite (FeCO) (as accessory minerals in the bentonite) and Fe-biotite (from the crushed granite). In the simulations, other chemical processes like cation exchange and surface complexation onto clay surfaces, and thermodynamic equilibrium with calcite, gypsum and quartz are considered. Initial composition of porewater is obtained by equilibrating the Forsmark groundwater with the backfill material. The 1D simulation consists of a number of cells with no reactive minerals or organic matter representing granite. The central cell, however, contains oxygen and reactive minerals resembling a backfill. Oxygen is allowed to move only by diffusion. The 2D model simulates the interaction with a backfill of a granitic groundwater flowing through a fracture. Like in the 1D model, the backfill contains oxygen and reactive solids. The results are very similar in

  2. Hypercapnic Acidosis Preserves Gastric Mucosal Microvascular Oxygen Saturation in a Canine Model of Hemorrhage.

    NARCIS (Netherlands)

    Schwartges, Ingo; Picker, Olaf; Beck, Christopher; Scheeren, Thomas W. L.; Schwarte, Lothar A.

    2010-01-01

    The authors aimed to clarify the effects of hypercapnic acidosis and its timing on gastric mucosal oxygenation in a canine model of hemorrhage. This was designed as a prospective, controlled, randomized animal study set in a university research laboratory. Five chronically instrumented dogs were

  3. Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteers

    NARCIS (Netherlands)

    Bezemer, R.; Lima, A.; Myers, D.; Klijn, E.; Heger, M.; Goedhart, P.T.; Bakker, J.; Ince, C.

    2009-01-01

    INTRODUCTION: To assess potential metabolic and microcirculatory alterations in critically ill patients, near-infrared spectroscopy (NIRS) has been used, in combination with a vascular occlusion test (VOT), for the non-invasive measurement of tissue oxygen saturation (StO2), oxygen consumption, and

  4. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges

    International Nuclear Information System (INIS)

    Abay, T Y; Kyriacou, P A

    2016-01-01

    Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p  <  0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG. (paper)

  5. The influence of stellate ganglion transcutaneous electrical nerve stimulation on signal quality of pulse oximetry in prehospital trauma care.

    Science.gov (United States)

    Barker, Renate; Lang, Thomas; Hager, Helmut; Steinlechner, Barbara; Hoerauf, Klaus; Zimpfer, Michael; Kober, Alexander

    2007-05-01

    Accurate monitoring of the peripheral arterial oxygen saturation has become an important tool in the prehospital emergency medicine. This monitoring requires an adequate plethysmographic pulsation. Signal quality is diminished by cold ambient temperature due to vasoconstriction. Blockade of the stellate ganglion can improve peripheral vascular perfusion and can be achieved by direct injection or transcutaneous electrical nerve stimulation (TENS) stimulation. We evaluated whether TENS on the stellate ganglion would reduce vasoconstriction and thereby improve signal detection quality of peripheral pulse oximetry. In our study, 53 patients with minor trauma who required transport to the hospital were enrolled. We recorded vital signs, including core and skin temperature before and after transport to the hospital. Pulse oximetry sensors were attached to the patient's second finger on both hands. TENS of the stellate ganglion was started on one side after the beginning of the transport. Pulse oximeter alerts, due to poor signal detection, were recorded for each side separately. On the hand treated with TENS we detected a significant reduction of alerts compared to the other side (mean alerts TENS 3.1 [1-15] versus control side 8.8 [1-28] P signal quality of pulse oximeters in the prehospital setting.

  6. Optimal filter bandwidth for pulse oximetry

    Science.gov (United States)

    Stuban, Norbert; Niwayama, Masatsugu

    2012-10-01

    Pulse oximeters contain one or more signal filtering stages between the photodiode and microcontroller. These filters are responsible for removing the noise while retaining the useful frequency components of the signal, thus improving the signal-to-noise ratio. The corner frequencies of these filters affect not only the noise level, but also the shape of the pulse signal. Narrow filter bandwidth effectively suppresses the noise; however, at the same time, it distorts the useful signal components by decreasing the harmonic content. In this paper, we investigated the influence of the filter bandwidth on the accuracy of pulse oximeters. We used a pulse oximeter tester device to produce stable, repetitive pulse waves with digitally adjustable R ratio and heart rate. We built a pulse oximeter and attached it to the tester device. The pulse oximeter digitized the current of its photodiode directly, without any analog signal conditioning. We varied the corner frequency of the low-pass filter in the pulse oximeter in the range of 0.66-15 Hz by software. For the tester device, the R ratio was set to R = 1.00, and the R ratio deviation measured by the pulse oximeter was monitored as a function of the corner frequency of the low-pass filter. The results revealed that lowering the corner frequency of the low-pass filter did not decrease the accuracy of the oxygen level measurements. The lowest possible value of the corner frequency of the low-pass filter is the fundamental frequency of the pulse signal. We concluded that the harmonics of the pulse signal do not contribute to the accuracy of pulse oximetry. The results achieved by the pulse oximeter tester were verified by human experiments, performed on five healthy subjects. The results of the human measurements confirmed that filtering out the harmonics of the pulse signal does not degrade the accuracy of pulse oximetry.

  7. Simultaneous estimation of arterial and venous oxygen saturation using a camera

    Science.gov (United States)

    van Gastel, Mark; Liang, Hangbing; Stuijk, Sander; de Haan, Gerard

    2018-02-01

    Optical monitoring of arterial blood oxygenation, SpO2, using cameras has recently been shown feasible by measuring the relative amplitudes of the remotely sensed PPG waveforms captured at different wavelengths. SvO2 measures the venous blood oxygenation which together with SpO2 provides an indication of tissue oxygen consumption. In contrast to SpO2 it usually still requires a blood sample from a pulmonary artery catheter. In this work we present a method which suggests simultaneous estimation of SpO2 and SvO2 with a camera. Contrary to earlier work, our method does not require external cuffs leading to better usability and improved comfort. Since the arterial blood varies synchronously with the heart rate, all frequencies outside the heart rate band are typically filtered out for SpO2 measurements. For SvO2 estimation, we include intensity variations in the respiratory frequency range since respiration modulates venous blood due to intrathoracic pressure variations in the chest and abdomen. Consequently, under static conditions, the two dominant components in the PPG signals are respiration and pulse. By measuring the amplitude ratios of these components, it seems possible to monitor both SpO2 and SvO2 continuously. We asked healthy subjects to follow an auditory breathing pattern while recording the face and hand. Results show a difference in estimated SpO2 and SvO2 values in the range 5-30 percent for both anatomical locations, which is normal for healthy people. This continuous, non-contact, method shows promise to alert the clinician to a change in patient condition sooner than SpO2 alone.

  8. Intelligent Approach for Analysis of Respiratory Signals and Oxygen Saturation in the Sleep Apnea/Hypopnea Syndrome

    Science.gov (United States)

    Moret-Bonillo, Vicente; Alvarez-Estévez, Diego; Fernández-Leal, Angel; Hernández-Pereira, Elena

    2014-01-01

    This work deals with the development of an intelligent approach for clinical decision making in the diagnosis of the Sleep Apnea/Hypopnea Syndrome, SAHS, from the analysis of respiratory signals and oxygen saturation in arterial blood, SaO2. In order to accomplish the task the proposed approach makes use of different artificial intelligence techniques and reasoning processes being able to deal with imprecise data. These reasoning processes are based on fuzzy logic and on temporal analysis of the information. The developed approach also takes into account the possibility of artifacts in the monitored signals. Detection and characterization of signal artifacts allows detection of false positives. Identification of relevant diagnostic patterns and temporal correlation of events is performed through the implementation of temporal constraints. PMID:25035712

  9. Corrosion Resistance of Steels and Armco-Fe in Lead Melt Saturated by Oxygen at 550 degree C

    International Nuclear Information System (INIS)

    Tsisar, V.P.; Fedirko, V.N.; Eliseeva, O.I.

    2007-01-01

    Corrosion resistance of stainless steels and Armco-Fe in static lead melt saturated by oxygen at 550 degree C for 2000 h was investigated. It was determined that double oxide layer was formed on the surface of investigated materials. Outer part of double oxide growths from the initial interface 'solid metal/liquid lead' towards the melt and consists of Fe 3 O 4 . Inner part of double oxide based on the matrix is composed of Fe 3 O 4 for Armco-Fe, Fe 1+x Cr 2-x O 4 for martensitic 0.2 C-13 Cr and ferritic-martensitic EP823 steels and Fe 1+x Cr 2- xO 4 +Ni for austenitic 18Cr-10Ni-1Ti. Lead did not penetrate into the matrix of tested materials and was detected only in the scale formed on austenitic steel

  10. Effects of blood transfusion on oxygen extraction ratio and central venous saturation in children after cardiac surgery.

    Science.gov (United States)

    Nasser, Bana; Tageldein, Mohmad; AlMesned, Abdulrahman; Kabbani, Mohammad

    2017-01-01

    Red blood cell transfusion is common in critically ill children after cardiac surgery. Since the threshold for hemoglobin (Hb) transfusion need is not well defined, the threshold Hb level at which dependent critical oxygen uptake-to-delivery (VO2-DO2) status compensation is uncertain. To assess the effects of blood transfusion on the oxygen extraction ratio (O2ER) and central venous oxygen saturation (ScvO2) to identify a critical O2ER value that could help us determine the critical need for blood transfusion. Prospective, observational cohort study. Cardiac Surgical Intensive Care Unit at Prince Sultan Cardiac Center in Qassim, Saudi Arabia. Between January 2013 and December 2015, we included all children with cardiac disease who underwent surgery and needed a blood transfusion. Demographic and laboratory data with physiological parameters before and 1 and 6 hours after transfusion were recorded and O2ER before and 6 hours after transfusion was computed. Cases were divided into two groups based on O2ER: Patients with increased O2ER (O2ER > 40%) and normal patients without increased O2ER (O2ER transfusion. Changes in O2ER and ScvO2 following blood transfusion. Of 103 patients who had blood transfusion, 75 cases had normal O2ER before transfusion while 28 cases had increased O2ER before transfusion. Following blood transfusion, O2ER and ScvO2 improved in the group that had increased O2ER before transfusion, but not in the group that had normal O2ER before transfusion. The clinical and hemodynamic indicators O2ER and ScvO2 may be considered as markers that can indicate a need for blood transfusion. The limitation of this study is the small number of patients that had increased O2ER before transfusion. There were few available variables to assess oxygen consumption.

  11. Inter-eye comparison of retinal oximetry and vessel caliber between eyes with asymmetrical glaucoma severity in different glaucoma subtypes

    Directory of Open Access Journals (Sweden)

    Cheng CS

    2016-07-01

    differences in oximetric parameters or vessel calibers between the worse and the better eyes in POAG and NTG groups. Conclusion: Eyes with PACG showed increased arteriolar oxygen saturation and increased AV difference. This was not observed in POAG and NTG eyes. Arteriolar diameter in PACG and venular diameter in all three glaucoma groups were reduced. The difference observed in PACG eyes may be due to an increased metabolic demand in the disease process compared to open-angle glaucoma. Keywords: glaucoma, oximetry, retinal vessels, imaging

  12. Influence of the depth of sedation on regional cerebral oxygen saturation monitoring in neurosurgery of supratentorial gliomas

    Directory of Open Access Journals (Sweden)

    ZHANG Kai⁃ying

    2012-12-01

    Full Text Available Objective To investigate the influence on regional cerebral oxygen saturation (rScO2 of sedation depth during anesthesia induction and maintenance in supratentorial glioma resections. Methods Thirty patients with Ⅰ - Ⅱ supratentorial glioma (graded by American Society of Anesthesiologists underwent elective supratentorial glioma resection were included in this study. Rocuronium, sufentanil and propofol were used for anesthesia induction. After trachea cannula, total intravenous anesthesia (TIVA was maintained with plasma concentration of propofol 2.80-3.20 μg/ml and remifentanil 0.10-0.20 μg/(kg·min. Thirty groups of rScO2, bispectral index (BIS, mean arterial pressure (MAP and heart rate (HR were recorded continuously till the incision. Results During anesthesia induction, BIS decreased along with the infusion of anesthetics, and there was significant negative correlation between BIS and rScO2 (r = ⁃0.803, P = 0.001. During anesthesia maintenance, rScO2 and BIS were not significantly related (r = 0.147, P = 0.396. Conclusion The rScO2 monitoring can reflect the influence of sedation depth on cerebral oxygen delivery and consumption balance during supratentorial glioma resection under TIVA.

  13. RAPID COMMUNICATION: A novel time frequency-based 3D Lissajous figure method and its application to the determination of oxygen saturation from the photoplethysmogram

    Science.gov (United States)

    Addison, Paul S.; Watson, James N.

    2004-11-01

    We present a novel time-frequency method for the measurement of oxygen saturation using the photoplethysmogram (PPG) signals from a standard pulse oximeter machine. The method utilizes the time-frequency transformation of the red and infrared PPGs to derive a 3D Lissajous figure. By selecting the optimal Lissajous, the method provides an inherently robust basis for the determination of oxygen saturation as regions of the time-frequency plane where high- and low-frequency signal artefacts are to be found are automatically avoided.

  14. EVALUATION OF CONDITION OF THE PULP BY PULSE OXIMETRY.

    Directory of Open Access Journals (Sweden)

    Dimitar Kosturkov

    2015-12-01

    Full Text Available Purpose: To conduct pulse oximetry (PO and electric pulp test (EPT on intact frontal teeth in clinically healthy patients aged between 18 and 25 years who do not have periodontal disease. Material/Methods: To achieve the aim 1058 teeth of 31 patients were studied. The following inclusion criteria for the study were set: 1. Age – 18-25 years. 2. Clinically healthy patient, who does not have any systemic diseases, do not take any medicine systematically. 3. Intact frontal teeth – without carious lesions, restorations or root canal treatment. 4. Lack of periodontal disease. Research was conducted with a pulse oximeter Contec™ - CMS60D and a custom made probe holder. Results: Average values obtained by pulse oximetry in upper jaw vary between 83% and 85%. In lower jaw – between 82% and 85%. 99% is the maximum and 48% is the minimum registered value. The average value of the measurement of all the teeth is 84%. The average saturation measured on the small finger of the right hand of the patient is 98%. The average value of EPT for all teeth is 4 μA. The maximum measured value is 20 μA, and the minimum - 1 μA. Conclusions: 1. Adequate study of the pulp includes two complementary methods – electric pulp test (evaluation of innervation and pulse oximetry (assessment of pulp microcirculation. 2. Teeth that are larger in size have larger values of PO and EPT, which is in direct relation to the size of their pulp chamber. 3. The total saturation, measured in the little finger of the right hand is greater than the one of the teeth.

  15. Evaluation of Masimo signal extraction technology pulse oximetry in anaesthetized pregnant sheep.

    Science.gov (United States)

    Quinn, Christopher T; Raisis, Anthea L; Musk, Gabrielle C

    2013-03-01

    Evaluation of the accuracy of Masimo signal extraction technology (SET) pulse oximetry in anaesthetized late gestational pregnant sheep. Prospective experimental study. Seventeen pregnant Merino ewes. Animals included in study were late gestation ewes undergoing general anaesthesia for Caesarean delivery or foetal surgery in a medical research laboratory. Masimo Radical-7 pulse oximetry (SpO(2) ) measurements were compared to co-oximetry (SaO(2) ) measurements from arterial blood gas analyses. The failure rate of the pulse oximeter was calculated. Accuracy was assessed by Bland & Altman's (2007) limits of agreement method. The effect of mean arterial blood pressure (MAP), perfusion index (PI) and haemoglobin (Hb) concentration on accuracy were assessed by regression analysis. Forty arterial blood samples paired with SpO(2) and blood pressure measurements were obtained. SpO(2) ranged from 42 to 99% and SaO(2) from 43.7 to 99.9%. MAP ranged from 24 to 82 mmHg, PI from 0.1 to 1.56 and Hb concentration from 71 to 114 g L(-1) . Masimo pulse oximetry measurements tended to underestimate oxyhaemoglobin saturation compared to co-oximetry with a bias (mean difference) of -2% and precision (standard deviation of the differences) of 6%. Accuracy appeared to decrease when SpO(2) was oximeter function during extreme hypotension and hypoxaemia. © 2012 The Authors. Veterinary Anaesthesia and Analgesia. © 2012 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.

  16. Oxygen titration strategies in chronic neonatal lung disease.

    Science.gov (United States)

    Primhak, Robert

    2010-09-01

    The history of oxygen therapy in neonatology has been littered with error. Controversies remain in a number of areas of oxygen therapy, including targets and strategies in supplemental oxygen therapy in Chronic Neonatal Lung Disease (CNLD). This article reviews some of these controversies, and makes some recommendations based on the available evidence. In graduates of neonatal units who are left with CNLD, oxygen saturation should be kept above 93-95%, with levels below 90% being avoided as far as possible. Titration of oxygen should be done using oximetry recordings which include periods of different activities. Weaning of oxygen supplementation should only be done based on satisfactory recordings during a trial of a lower flow. There is insufficient evidence to say whether weaning for increasing hours a day or stepwise weaning to a continuous lower flow is a better method. Copyright 2010 Elsevier Ltd. All rights reserved.

  17. The Effects of Massage with Coconut and Sunflower Oils on Oxygen Saturation of Premature Infants with Respiratory Distress Syndrome Treated With Nasal Continuous Positive Airway Pressure

    Directory of Open Access Journals (Sweden)

    Sousan Valizadeh

    2012-11-01

    Full Text Available Introduction: Nowadays particular emphasis is placed on the developmental aspects of premature infants care. Massage therapy is one of the best-known methods of caring. Due to the minimal touch policy in neonatal intensive care units (NICUs, massaging is not usually performed on premature infants. However, there is not sufficient evidence to support the claim that newborn infants with complex medical conditions should not be massaged. This study aimed to determine the effects of massage with coconut and sunflower oils on oxygen saturation of infants with respiratory distress syndrome (RDS treated with nasal continuous positive airway pressure (NCPAP. Methods: This was a randomized controlled trial on 90 newborns who were admitted to Alzahra Hospital (Tabriz, Iran. The infants were divided into control and massage therapy groups (massage with coconut and sunflower oils. Data was collected using a hospital documentation form. A 15-minute daily massage was performed for 3 days. Respiratory rate (RR, fraction of inspired oxygen (FiO2 and oxygen saturation were measured 5 minutes before the massage, 3 times during the massage, and 5 minutes after the massage. The collected data was analyzed using a mixed model. Results: In comparison to coconut oil and control groups, mean oxygen saturation of sunflower oil group was improved. In addition, the coconut massage group showed lower oxygen saturation than the control group but was all values were within the normal range. Although massage decreased oxygen saturation, there was no need to increase FiO2. Conclusion: Massage therapy can provide developmental care for infants treated with NCPAP.

  18. The Effect of Non-nutritive Sucking on Transcutaneous Oxygen Saturation in Neonates under the Nasal Continuous Positive Airway Pressure (CPAP

    Directory of Open Access Journals (Sweden)

    Mousa Ahmadpour-kacho

    2017-03-01

    Full Text Available BackgroundSeveral beneficial effects of non-nutritive sucking in infants, including the physiological stability, relaxation, better transition from tube feeding to oral feeding have been reported. But its effect on oxygen saturation in neonates under the Nasal Continuous Positive Airway Pressure (NCPAPو (is not so clear. This study aimed to investigate the effects of non-nutritive sucking on transcutaneous oxygen saturation levels of neonates treated with NCPAP.Materials and MethodsThis quasi-experimental study was done on 25 preterm neonates, hospitalized with a diagnosis of respiratory distress, required NCPAP, in the neonatal intensive care unit (NICU at the Ayatollah Rouhani Hospital and Babol Clinic, North of Iran. Non-nutritive sucking was elicited by a standard pacifier appropriate to their age one hour a day, and the mean oxygen saturation was measured before and after intervention by cardiopulmonary monitoring (Saadat Co., Iran. Data analyzed using SPSS-18.0 software.ResultsIn the 25 cases studied, the mean oxygen saturation values ​​before performing non-nutritive sucking was 96.31±2.88%, which was changed to 98.35±1.6% after intervention, and this increase was statistically significant (P = 0.004.Results showed that the gender, birth weight and gestational age of neonates had no effect on mean Blood oxygen saturation (SpO2level.ConclusionAccording to the results, using the non-nutritive sucking in premature neonates under the NCPAP, can improve oxygenation.

  19. Cerebral near infrared spectroscopy oximetry in extremely preterm infants : Phase II randomised clinical trial

    NARCIS (Netherlands)

    Hyttel-Sorensen, Simon; Pellicer, Adelina; Alderliesten, Thomas; Austin, Topun; Van Bel, Frank; Benders, Manon; Claris, Olivier; Dempsey, Eugene; Franz, Axel R.; Fumagalli, Monica; Gluud, Christian; Grevstad, Berit; Hagmann, Cornelia; Lemmers, Petra; Van Oeveren, Wim; Pichler, Gerhard; Plomgaard, Anne Mette; Riera, Joan; Sanchez, Laura; Winkel, Per; Wolf, Martin; Greisen, Gorm

    2015-01-01

    Objective: To determine if it is possible to stabilise the cerebral oxygenation of extremely preterm infants monitored by cerebral near infrared spectroscopy (NIRS) oximetry. Design: Phase II randomised, single blinded, parallel clinical trial. Setting Eight tertiary neonatal intensive care units in

  20. Lactate, endothelin, and central venous oxygen saturation as predictors of mortality in patients with Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Poonam Malhotra Kapoor

    2016-01-01

    Full Text Available Background: Lactate and central venous oxygen saturation (ScVO2 are well known biomarkers for adequacy of tissue oxygenation. Endothelin, an inflammatory marker has been associated with patient′s nutritional status and degree of cyanosis. The aim of this study was to explore the hypothesis that lactate, ScVO2 and endothelin before induction may be predictive of mortality in pediatric cardiac surgery. Methods: We conducted a prospective observational study of 150 pediatric (6 months to 12 years patients who were posted for intracardiac repair for tetralogy of fallot and measured lactate, ScVO2 and endothelin before induction (T1, 20 minutes after protamine administration (T2 and 24 hours after admission to ICU (T3. Results: Preinduction lactate and endothelin levels were found to predict mortality in patients of tetralogy of fallot with an odds ratio of 6.020 (95% CI 2.111-17.168 and 1.292(95% CI 1.091-1.531 respectively. In the ROC curve analysis for lactate at T1, the AUC was 0.713 (95% CI 0.526-0.899 P = 0.019. At the cutoff value of 1.750mmol/lt, the sensitivity and specificity for the prediction of mortality was 63.6% and 65.5%, respectively. For endothelin at T1, the AUC was 0.699 (95% CI 0.516-0.883, P = 0.028 and the cutoff value was ≤2.50 (sensitivity, 63.6%; specificity, 58.3 %. ScVO2 (odds ratio 0.85 at all three time intervals, suggested that improving ScVO2 can lead to 15% reduction in mortality. Conclusions: Lactate, ScVO2 and endothelin all showed association with mortality with lactate having the maximum prediction. Lactate was found to be an independent, reliable and cost-effective measure of prediction of mortality in patients with tetralogy of fallot.

  1. A multiplexed electronic architecture for opto-electronic patch sensor to effectively monitor heart rate and oxygen saturation

    Science.gov (United States)

    Yan, Liangwen; Hu, Sijung; Alharbi, Samah; Blanos, Panagiotis

    2018-02-01

    To effectively capture human vital signs, a multi-wavelength optoelectronic patch sensor (MOEPS), together with a schematic architecture of electronics, was developed to overcome the drawbacks of present photoplethysmographic (PPG) sensors. To obtain a better performance of in vivo physiological measurement, the optimal illuminations, i.e., light emitting diodes (LEDs) in the MOEPS, whose wavelength is automatically adjusted to each specific subject, were selected to capture better PPG signals. A multiplexed electronic architecture has been well established to properly drive the MOEPS and effectively capture pulsatile waveforms at rest. The protocol was designed to investigate its performance with the participation of 11 healthy subjects aged between 18 and 30. The signals obtained from green (525nm) and orange (595nm) illuminations were used to extract heart rate (HR) and oxygen saturation (SpO2%). These results were compared with data, simultaneously acquired, from a commercial ECG and a pulse oximeter. Considering the difficulty for current devices to attain the SpO2%, a new computing method, to obtain the value of SpO2%, is proposed depended on the green and orange wavelength illuminations. The values of SpO2% between the MOEPS and the commercial Pulse Oximeter devics showed that the results were in good agreement. The values of HR showed close correlation between commercial devices and the MOEPS (HR: r1=0.994(Green); r2=0.992(Orange); r3=0.975(Red); r4=0.990(IR)).

  2. Cardiac function and oxygen saturation during maximal breath-holding in air and during whole-body surface immersion.

    Science.gov (United States)

    Marabotti, Claudio; Piaggi, Paolo; Menicucci, Danilo; Passera, Mirko; Benassi, Antonio; Bedini, Remo; L'Abbate, Antonio

    2013-09-01

    The magnitude of the oxygen-sparing effect induced by the diving response in humans is still under debate. We wished to compare cardiovascular changes during maximal breath-holding (BH) in air and during whole-body immersion at the surface in a group of BH divers. Twenty-one divers performed a maximal static apnea in air or during whole-body immersion. Dopplerechocardiography, arterial blood pressure and haemoglobin saturation (SaO₂) were obtained at the beginning of, and at 1/3, 2/3 and maximal BH time. BH time was on the average 3.6 ± 0.4 min, with no differences between the two conditions. SaO₂ significantly decreased during BH in both conditions, but was significantly higher during immersion as compared to the dry (P = 0.04). In both conditions, BH induced a significant linear increase in right ventricular diameter (P whole-body immersion, associated with reduced LV ejection fraction and progressive hindrance to diastolic filling. For a similar apnea duration, SaO₂ decreased less during immersed BH, indicating an O₂-sparing effect of diving, suggesting that interruption of apnea was not triggered by a threshold critical value of blood O₂ desaturation.

  3. A graphical method for comparing nocturnal oxygen saturation profiles in individuals and populations: Application to healthy infants and preterm neonates.

    Science.gov (United States)

    Terrill, Philip I; Dakin, Carolyn; Edwards, Bradley A; Wilson, Stephen J; MacLean, Joanna E

    2018-05-01

    Pulse-oximetry (SpO 2 ) allows the identification of important clinical physiology. However, summary statistics such as mean values and desaturation incidence do not capture the complexity of the information contained within continuous recordings. The aim of this study was to develop an objective method to quantify important SpO 2 characteristics; and assess its utility in healthy infant and preterm neonate cohorts. An algorithm was developed to calculate the desaturation incidence, depth, and duration. These variables are presented using three plots: SpO 2 cumulative-frequency relationship; desaturation-depth versus incidence; desaturation-duration versus incidence. This method was applied to two populations who underwent nocturnal pulse-oximetry: (1) thirty-four healthy term infants studied at 2-weeks, 3, 6, 12, and 24-months of age and (2) thirty-seven neonates born <26 weeks and studied at discharge from NICU (37-44 weeks post-conceptual age). The maturation in healthy infants was characterized by reduced desaturation index (27.2/h vs 3.3/h at 2-weeks and 24-months, P < 0.01), and increased percentage of desaturation events ≥6-s in duration (27.8% vs 43.2% at 2-weeks and 3-months, P < 0.01). Compared with term-infants, preterm infants had a greater desaturation incidence (54.8/h vs 27.2/h, P < 0.01), and these desaturations were deeper (52.9% vs 37.6% were ≥6% below baseline, P < 0.01). The incidence of longer desaturations (≥14-s) in preterm infants was correlated with healthcare utilization over the first 24-months (r = 0.63, P < 0.01). This tool allows the objective comparison of extended oximetry recordings between groups and for individuals; and serves as a basis for the development of reference ranges for populations. © 2018 Wiley Periodicals, Inc.

  4. In vivo electron paramagnetic resonance oximetry and applications in the brain

    Directory of Open Access Journals (Sweden)

    John M Weaver

    2017-01-01

    Full Text Available Molecular oxygen (O2 is essential to brain function and mechanisms necessary to regulate variations in delivery or utilization of O2 are crucial to support normal brain homeostasis, physiology and energy metabolism. Any imbalance in cerebral tissue partial pressure of O2 (pO2 levels may lead to pathophysiological complications including increased reactive O2 species generation leading to oxidative stress when tissue O2 level is too high or too low. Accordingly, the need for oximetry methods, which assess cerebral pO2 in vivo and in real time, is imperative to understand the role of O2 in various metabolic and disease states, including the effects of treatment and therapy options. In this review, we provide a brief overview of the common in vivo oximetry methodologies for measuring cerebral pO2 . We discuss the advantages and limitations of oximetry methodologies to measure cerebral pO2 in vivo followed by a more in-depth review of electron paramagnetic resonance oximetry spectroscopy and imaging using several examples of current electron paramagnetic resonance oximetry applications in the brain.

  5. Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution

    Directory of Open Access Journals (Sweden)

    Zhang Yuan-ting

    2005-03-01

    Full Text Available Abstract Background The pulse oximeter, a medical device capable of measuring blood oxygen saturation (SpO2, has been shown to be a valuable device for monitoring patients in critical conditions. In order to incorporate the technique into a wearable device which can be used in ambulatory settings, the influence of motion artifacts on the estimated SpO2 must be reduced. This study investigates the use of the smoothed psuedo Wigner-Ville distribution (SPWVD for the reduction of motion artifacts affecting pulse oximetry. Methods The SPWVD approach is compared with two techniques currently used in this field, i.e. the weighted moving average (WMA and the fast Fourier transform (FFT approaches. SpO2 and pulse rate were estimated from a photoplethysmographic (PPG signal recorded when subject is in a resting position as well as in the act of performing four types of motions: horizontal and vertical movements of the hand, and bending and pressing motions of the finger. For each condition, 24 sets of PPG signals collected from 6 subjects, each of 30 seconds, were studied with reference to the PPG signal recorded simultaneously from the subject's other hand, which was stationary at all times. Results and Discussion The SPWVD approach shows significant improvement (p Conclusion The results suggested that the SPWVD approach could potentially be used to reduce motion artifact on wearable pulse oximeters.

  6. Predicting blood transfusion using automated analysis of pulse oximetry signals and laboratory values.

    Science.gov (United States)

    Shackelford, Stacy; Yang, Shiming; Hu, Peter; Miller, Catriona; Anazodo, Amechi; Galvagno, Samuel; Wang, Yulei; Hartsky, Lauren; Fang, Raymond; Mackenzie, Colin

    2015-10-01

    Identification of hemorrhaging trauma patients and prediction of blood transfusion needs in near real time will expedite care of the critically injured. We hypothesized that automated analysis of pulse oximetry signals in combination with laboratory values and vital signs obtained at the time of triage would predict the need for blood transfusion with accuracy greater than that of triage vital signs or pulse oximetry analysis alone. Continuous pulse oximetry signals were recorded for directly admitted trauma patients with abnormal prehospital shock index (heart rate [HR] / systolic blood pressure) of 0.62 or greater. Predictions of blood transfusion within 24 hours were compared using Delong's method for area under the receiver operating characteristic (AUROC) curves to determine the optimal combination of triage vital signs (prehospital HR + systolic blood pressure), pulse oximetry features (40 waveform features, O2 saturation, HR), and laboratory values (hematocrit, electrolytes, bicarbonate, prothrombin time, international normalization ratio, lactate) in multivariate logistic regression models. We enrolled 1,191 patients; 339 were excluded because of incomplete data; 40 received blood within 3 hours; and 14 received massive transfusion. Triage vital signs predicted need for transfusion within 3 hours (AUROC, 0.59) and massive transfusion (AUROC, 0.70). Pulse oximetry for 15 minutes predicted transfusion more accurately than triage vital signs for both time frames (3-hour AUROC, 0.74; p = 0.004) (massive transfusion AUROC, 0.88; p transfusion prediction (3-hour AUROC, 0.84; p transfusion AUROC, 0.91; p blood transfusion during trauma resuscitation more accurately than triage vital signs or pulse oximetry analysis alone. Results suggest automated calculations from a noninvasive vital sign monitor interfaced with a point-of-care laboratory device may support clinical decisions by recognizing patients with hemorrhage sufficient to need transfusion. Epidemiologic

  7. Retinal oximetry in patients with ischaemic retinal diseases

    DEFF Research Database (Denmark)

    Rilvén, Sandra; Torp, Thomas Lee; Grauslund, Jakob

    2017-01-01

    The retinal oximeter is a new tool for non-invasive measurement of retinal oxygen saturation in humans. Several studies have investigated the associations between retinal oxygen saturation and retinal diseases. In the present systematic review, we examine whether there are associations between...... retinal oxygen saturation and retinal ischaemic diseases. We used PubMed and Embase to search for retinal oxygen saturation and retinal ischaemic diseases. Three separate searches identified a total of 79 publications. After two levels of manual screening, 10 studies were included: six about diabetic...... retinopathy (DR) and four about retinal vein occlusion. No studies about retinal artery occlusion were included. In diabetes, all studies found that increases in retinal venous oxygen saturation (rvSatO2 ) were associated with present as well as increasing levels of DR. Four of six studies also found...

  8. One hour effects of salbutamol and formoterol on blood pressure, heart rate and oxygen saturation in asthmatics

    Directory of Open Access Journals (Sweden)

    Geraldo Andrade Capuchinho-Júnior

    2008-05-01

    Full Text Available Aim: To analyse systolic (SBP and diastolic blood pressure (DBP, partial oxygen saturation (SpO2 and heart rate (HR disorders for an hour after short and long acting ß2-agonists. Material and methods: Twenty-four severe persistent asthma Pulmonology outpatients at Hospital Universitario Gaffree e Guinle were selected. SBP, DBP, SpO2 and HR values were determined before and after 400 μg of salbutamol and 12 μg of formoterol, on different days, with a minimum interval of 24 hours. Results: All patients showed ventilatory obstruction, as seen by a reduced FEV1/FVC ratio. There was no statistical SBP/DBP/HR difference after bronchodilator agents, but SpO2 increased with salbutamol. Conclusion: A standard dose of salbutamol and formoterol does not cause haemodynamic disorder. Resumo: Objectivo: Analisar os possíveis efeitos do uso de β-2-agonistas, de curta e longa duração, nas pressões arteriais sistólica (PAS e diastólica (PAD, na saturação parcial de oxigénio (SpO2 e na frequência cardíaca (FC, durante o período de uma hora. Material e métodos: Vinte e quatro doentes com asma persistente grave, em tratamento no ambulatório de Pneumologia do Hospital Universitário Gaffrée e Guinle, foram seleccionados para um ensaio clínico sequencial e cruzado. Os valores da PAS, PAD, SpO2 e FC foram registados antes e após o uso de broncodilatadores, salbutamol 400 μg e formoterol 12 μg, em dias diferentes, com intervalo mínimo de 24 horas. Resultados: Todos os doentes apresentaram distúrbio ventilatório obstrutivo, identificado pela redução da relação entre o volume expiratório forçado no primeiro segundo (VEMS e a capacidade vital forçada (CVF. Após o uso de substância broncodilatadora, não houve variação significativa nas PAS e PAD, nem na FC; porém, a SpO2 aumentou com o uso de salbutamol. Conclusão: Não foram observadas

  9. Relationship between intraoperative regional cerebral oxygen saturation trends and cognitive decline after total knee replacement: a post-hoc analysis.

    Science.gov (United States)

    Salazar, Fátima; Doñate, Marta; Boget, Teresa; Bogdanovich, Ana; Basora, Misericordia; Torres, Ferran; Gracia, Isabel; Fàbregas, Neus

    2014-01-01

    Bilateral regional brain oxygen saturation (rSO2) trends, reflecting intraoperative brain oxygen imbalance, could warn of brain dysfunction. Various types of cognitive impairment, such as memory decline, alterations in executive function or subjective complaints, have been described three months after surgery. Our aim was to explore the potential utility of rSO2 values as a warning sign for the development of different types of decline in postoperative psychological function. Observational post-hoc analysis of data for the patient sample (n = 125) of a previously conducted clinical trial in patients over the age of 65 years undergoing total knee replacement under spinal anesthesia. Demographic, hemodynamic and bilateral rSO2 intraoperative values were recorded. An absolute rSO2 value of 20% or >25% below baseline were chosen as relevant cutoffs. Composite function test scores were created from baseline to three months for each patient and adjusted for the mean (SD) score changes for a control group (n = 55). Tests were used to assess visual-motor coordination and executive function (VM-EF) (Wechsler Digit Symbol-Coding and Visual Reproduction, Trail Making Test) and memory (Auditory Verbal Learning, Wechsler Memory Scale); scales were used to assess psychological symptoms. We observed no differences in baseline rSO2 values; rSO2 decreased significantly in all patients during surgery (P Left and right rSO2 values were asymmetric in patients who had memory decline (mean [SD] left-right ratio of 95.03 [8.51] vs 101.29 [6.7] for patients with no changes, P = 0.0012). The mean right-left difference in rSO2 was also significant in these patients (-2.87% [4.73%], lower on the right, P = 0.0034). Detection of a trend to asymmetry in rSO2 values can warn of possible postoperative onset of memory decline. Psychological symptoms and memory decline were common three months after knee replacement in our patients over the age of 65 years.

  10. Dependence of diameters and oxygen saturation of retinal vessels on visual field damage and age in primary open-angle glaucoma.

    Science.gov (United States)

    Ramm, Lisa; Jentsch, Susanne; Peters, Sven; Sauer, Lydia; Augsten, Regine; Hammer, Martin

    2016-05-01

    To investigate the interrelationship between the oxygen supply of the retina and its regulation with the severity of primary open-angle glaucoma (POAG). Central retinal artery (CRAE) and vein (CRVE) diameters and oxygen saturation of peripapillary retinal vessels in 41 patients suffering from POAG (64.1 ± 12.9 years) and 40 healthy volunteers (63.6 ± 14.1 years) were measured using the retinal vessel analyzer. All measures were taken before and during flicker light stimulation. The mean retinal nerve fiber layer thickness (RNFLT) was determined by OCT and the visual field mean defect (MD) was identified using perimetry. In glaucoma patients, CRAE (r = -0.48 p = 0.002) and CRVE (r = -0.394 p = 0.014) at baseline were inversely related to MD, while arterial and venous oxygen saturation showed no significant dependence on the severity of the damage. However, the flicker light-induced change in arterio-venous difference in oxygen saturation was correlated with the MD (r = 0.358 p = 0.027). The diameters of arteries and veins at baseline decreased with reduction of the mean RNFLT (arteries: r = 0.718 p field loss, may be explained by a reduction of the retinal metabolic demand with progressive loss of neuronal tissue in glaucoma. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  11. Effects of beach-chair position and induced hypotension on cerebral oxygen saturation in patients undergoing arthroscopic shoulder surgery.

    Science.gov (United States)

    Lee, Jae Hoon; Min, Kyeong Tae; Chun, Yong-Min; Kim, Eun Jung; Choi, Seung Ho

    2011-07-01

    We investigated the effects of the beach-chair position and induced hypotension on regional cerebral oxygen saturation (rSO(2)) in patients undergoing arthroscopic shoulder surgery by using near-infrared spectroscopy. Twenty-eight patients scheduled for arthroscopic shoulder surgery were enrolled prospectively. After induction of anesthesia, mechanical ventilation was controlled to maintain Paco(2) at 35 to 40 mm Hg. Anesthesia was maintained with sevoflurane and remifentanil. After radial artery cannulation, mean arterial pressure (MAP) was measured at the external auditory meatus level and maintained between 60 and 65 mm Hg. The rSO(2) was measured by use of near-infrared spectroscopy. MAP and rSO(2) were recorded at the following times: before induction (T(0)), immediately after induction (T(1) [baseline]), after beach-chair position (T(2)), immediately after induced hypotension (T(3)), 1 hour after induced hypotension (T(4)), and after supine position at the end of surgery (T(5)). Cerebral desaturation was defined as a reduction in rSO(2) to less than 80% of baseline value for 15 seconds or greater. A total of 27 patients were evaluated until the end of this study. The MAP at T(2) was significantly lower than that at T(1). The MAP values at T(3) and T(4) were significantly lower than those at T(1) and T(2). The rSO(2) at T(2) was significantly lower than that at T(1). Unlike the pattern of change in the MAP, there was no additional decrease in rSO(2) at T(3) and T(4). There were 2 patients who had an episode of cerebral desaturation. The beach-chair position combined with induced hypotension significantly decreases rSO(2) in patients undergoing shoulder arthroscopic surgery under general anesthesia. Level IV, study of nonconsecutive patients without consistently applied reference gold standard. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Improving pulse oximetry accuracy by removing motion artifacts from photoplethysmograms using relative sensor motion: a preliminary study

    NARCIS (Netherlands)

    Wijshoff, R.W.C.G.R.; Mischi, M.; Woerlee, P.H.; Aarts, R.M.; Van Huffel, S.; Naelaers, G.; Caicedo, A.; Bruley, D.F.; Harrison, D.K.

    2013-01-01

    To expand applicability of pulse oximetry in low-acuity ambulatory settings, the impact of motion on extracted parameters as saturation (SpO2) and pulse rate (PR) needs to be reduced. We hypothesized that sensor motion relative to the skin can be used as an artifact reference in a correlation

  13. Vagal activity and oxygen saturation response to hypoxia: Effects of aerobic fitness and rating of hypoxia tolerance

    Directory of Open Access Journals (Sweden)

    Tomáš Macoun

    2017-10-01

    Full Text Available Background: A reduction in the inspired oxygen fraction (FiO2 induces a decline in arterial oxygen saturation (SpO2 and changes of heart rate variability (HRV. It has been shown that SpO2 and HRV responses to similar levels of acute normobaric hypoxia are inter-individual variable. Variable response may be influenced by normoxia reached maximal oxygen uptake (VO2max value. Objective: The primary aim was to assess HRV and the SpO2 response to hypoxia, and examine the association with normoxic VO2max. Methods: Supine HRV and SpO2 were monitored during normobaric hypoxia (FiO2 = 9.6% for 10 minutes in 28 subjects, aged 23.7 ± 1.7 years. HRV was evaluated by using both spectral and time domain HRV analysis. Low frequency (LF, 0.05-0.15 Hz and high frequency (HF, 0.15-0.50 Hz power together with square root of the mean of the squares of the successive differences (rMSSD were calculated and transformed by natural logarithm (Ln. Based on the SpO2 in hypoxia, subjects were divided into Resistant (RG, SpO2 ≥ 70.9%, n = 14 and Sensitive (SG, SpO2 < 70.9%, n = 14 groups. Perceived hypoxia tolerance was self-scored on a 4-level scale. Results: VO2max was higher in SG (62.4 ± 7.2 ml ⋅ kg-1 ⋅ min-1 compared with RG (55.5 ± 7.1 ml ⋅ kg-1 ⋅ min-1, p = .017, d = 0.97. A significant relationship (r = -.45, p = .017 between hypoxic-normoxic difference in SpO2 and normoxic VO2max level was found. Vagal activity (Ln rMSSD was significantly decreased (SG: p < .001, d = 2.64; RG: p < .001, d = 1.22, while sympathetic activity (Ln LF/HF was relatively increased (p < .001, d = -1.40 in only the SG during hypoxia. Conclusions: Results show that subjects with a higher aerobic capacity exhibited a greater decline in SpO2, accompanied by greater autonomic cardiac disturbances during hypoxia. The SpO2 reduction was associated with perceived hypoxia comfort/discomfort. The hypoxia

  14. Cerebral time domain-NIRS: Reproducibility analysis, optical properties, hemoglobin species and tissue oxygen saturation in a cohort of adult subjects

    OpenAIRE

    Giacalone, Giacomo; Zanoletti, Marta; Contini, Davide; Rebecca, Re; Spinelli, Lorenzo; Roveri, Luisa; Torricelli, Alessandro

    2017-01-01

    The reproducibility of cerebral time-domain near-infrared spectroscopy (TD-NIRS) has not been investigated so far. Besides, reference intervals of cerebral optical properties, of absolute concentrations of deoxygenated-hemoglobin (HbR), oxygenated-hemoglobin (HbO), total hemoglobin (HbT) and tissue oxygen saturation (StO2) and their variability have not been reported. We have addressed these issues on a sample of 88 adult healthy subjects. TD-NIRS measurements at 690, 785, 830 nm were fitted ...

  15. Blood gases and oxygen saturation response to active cycle of breathing techniques in COPD patients during phase I of cardiac rehabilitation

    International Nuclear Information System (INIS)

    Sheraz, S.; Siddiqi, F.A.

    2015-01-01

    Objective: To determine the effectiveness of active cycle of breathing techniques (ACBTs) on arterial blood gases (ABG), oxygen saturation and other vitals including chest expansion, heart rate, and respiratory rate in COPD patients during phase I of cardiac rehabilitation program after open heart surgery. Methodology: In this experimental study, sample size chosen was 100 patients, randomly divided into experimental (n=50) and control (n=50) groups. Pre-test values of ABG, oxygen saturation, chest expansion, respiratory rate, and heart rate of the participants were taken. Then, conventional physical therapy including spirometry was performed 2 hourly by the control group whereas the experimental group performed ACBTs along with spirometry twice a day for a period of one week. Participants were re-assessed after one week treatment. Results: There was highly significant difference (p<0.01) in pre-test and post-test values of PCO/sub 2/ and oxygen saturation in experimental group as compared to control group. The results of bicarbonate values, base excess and heart rate were statistically significant (p<0.01) in control group and there was no significant difference (p>0.05) in experimental group. The values of pH, chest expansion and respiratory rate were highly significant (p<0.01) in both control as well as experimental group. Conclusion: ACBT was more effective to decrease post CABG complication as compared to conventional chest physical therapy. Some parameters like bicarbonate values, base excess and heart rate did not show improvement with ACBT. (author)

  16. Hypoxemia Episodes during Day and Night and Their Impact on Oxygen Saturation Targeting in Mechanically Ventilated Preterm Infants.

    Science.gov (United States)

    Jain, Deepak; D'Ugard, Carmen; Bello, Jose; Bancalari, Eduardo; Claure, Nelson

    2018-01-01

    Hypoxemia episodes (HE) occur frequently in ventilated preterm infants and hinder the achievement of arterial oxygen saturation (SpO2) targets. These episodes may increase the risk for retinopathy of prematurity and neurodevelopmental disability. There are no data on the variation in HE and SpO2 targeting between day and night. The aim of this study was to evaluate the difference between day and night on the frequency and severity of HE and achievement of SpO2 targets. Twenty-four mechanically ventilated preterm infants with ≥4 episodes of SpO2 day (9 a.m. to 5 p.m.) were compared to the night (9 p.m. to 5 a.m.) for the frequency of HE and proportion of time within and outside the target SpO2 range (90-95%). The frequency of severe HE (SpO2 night compared to the day (1.6 ± 1.0 vs. 2.4 ± 1.3 episodes/h, p = 0.008, and 0.53 ± 0.35 vs. 0.90 ± 0.54 episodes/h, p = 0.018). There was no difference in mean episode duration. The frequency and duration of mild HE (SpO2 night compared to the day (5.9 ± 2.7 vs. 7.1 ± 2.5 episodes/h, p = 0.003, and 72 ± 15 vs. 87 ± 25 s, p = 0.01, respectively). The proportion of time in severe hypoxemia (SpO2 95%) was greater, during the night compared to the day. The mean FiO2 did not differ between day and night. In this group of infants with frequent HE, nighttime was associated with fewer episodes when compared to daytime. This is likely due to less handling and sensory stimulation during the night. The increase in time spent with hyperoxemia during the night is likely to be due to more tolerance of high SpO2 with less proactive weaning of FiO2. © 2017 S. Karger AG, Basel.

  17. Heart Rate and Oxygen Saturation Change Patterns During 6-min Walk Test in Subjects With Chronic Thromboembolic Pulmonary Hypertension.

    Science.gov (United States)

    Inagaki, Takeshi; Terada, Jiro; Yahaba, Misuzu; Kawata, Naoko; Jujo, Takayuki; Nagashima, Kengo; Sakao, Seiichiro; Tanabe, Nobuhiro; Tatsumi, Koichiro

    2017-12-26

    The 6-min walk test (6MWT) is commonly performed to assess functional status in patients with chronic thromboembolic pulmonary hypertension. However, changes in heart rate and oxygen saturation ( S pO 2 ) patterns during 6MWT in patients with chronic thromboembolic pulmonary hypertension remain unclear. Thirty-one subjects with chronic thromboembolic pulmonary hypertension were retrospectively evaluated to examine the relationships between the change in heart rate (Δheart rate), heart rate acceleration time, slope of heart rate acceleration, heart rate recovery during the first minute after 6MWT (HRR1), change in S pO 2 (Δ S pO 2 ), S pO 2 reduction time, and S pO 2 recovery time during 6MWT, and the severity of pulmonary hemodynamics assessed by right heart catheterization and echocardiography. Subjects with severe chronic thromboembolic pulmonary hypertension had significantly longer heart rate acceleration time (144.9 ± 63.9 s vs 96.0 ± 42.5 s, P = .033), lower Δheart rate (47.4 ± 16.9 vs 61.8 ± 13.6 beats, P = .02), and lower HRR1 (13.3 ± 9.0 beats vs 27.1 ± 9.2 beats, P pulmonary hypertension. Subjects with severe chronic thromboembolic pulmonary hypertension also had significantly longer S pO 2 reduction time (178.3 ± 70.3 s vs 134.3 ± 58.4 s, P = .03) and S pO 2 recovery time (107.6 ± 35.3 s vs 69.8 ± 32.7 s, P = .004) than did subjects with mild chronic thromboembolic pulmonary hypertension. Multivariate linear regression analysis showed only mean pulmonary arterial pressure independently was associated with heart rate acceleration time and slope of heart rate acceleration. Heart rate and S pO 2 change patterns during 6MWT is predominantly associated with pulmonary hemodynamics in subjects with chronic thromboembolic pulmonary hypertension. Evaluating heart rate and S pO 2 change patterns during 6MWT may serve a safe and convenient way to follow the change in pulmonary hemodynamics. Copyright © 2017 by Daedalus Enterprises.

  18. Near-Infrared Spectroscopic Measurement of the Effect of Leg Dominance on Muscle Oxygen Saturation During Cycling

    Science.gov (United States)

    Ellerby, Gwenn E. C.; Lee, Stuart M. C.; Paunescu, Lelia Adelina; Pereira, Chelsea; Smith, Charles P.; Soller, Babs R.

    2011-01-01

    The effect of leg dominance on the symmetry of the biomechanics during cycling remains uncertain -- asymmetries have been observed in kinematics and kinetics, while symmetries were found in muscle activation. No studies have yet investigated the symmetry of muscle metabolism during cycling. Near-infrared spectroscopy (NIRS) provides a non-invasive method to investigate the metabolic responses of specific muscles during cycling. PURPOSE: To determine whether there was an effect of leg dominance on thigh muscle oxygen saturation (SmO2) during incrementally loaded submaximal cycling using NIRS. METHODS: Eight right leg dominant, untrained subjects (5 men, 3 women; 31+/-2 yrs; 168.6+/-1.0 cm; 67.2+/-1.8 kg, mean +/- SE) volunteered to participate. Spectra were collected bilaterally from the vastus lateralis (VL) during supine rest and cycling. SmO2 was calculated using previously published methods. Subjects pedaled at 65 rpm while resistance to pedaling was increased in 0.5 kp increments from 0.5 kp every 3 min until the subject reached 80% of age-predicted maximal heart rate. SmO2 was averaged over 3 min for each completed stage. A two-way ANOVA was performed to test for leg differences. A priori contrasts were used to compare work levels to rest. RESULTS: VL SmO2 was not different between the dominant and non-dominant legs at rest and during exercise (p=0.57). How SmO2 changed with workload was also not different between legs (p=0.32). SmO2 at 0.5 kp (60.3+/-4.0, p=0.12) and 1.0 kp (59.5+/-4.0, p=0.10) was not different from rest (69.1+/-4.0). SmO2 at 1.5 kp (55.4 4.0, p=0.02), 2.0 kp (55.7+/-5.0, p=0.04), and 2.5 kp (43.4+/-7.9, p=0.01) was significantly lower than rest. CONCLUSION: VL SmO2 during cycling is not different between dominant and non-dominant legs and decreases with moderate workload in untrained cyclists. Assuming blood flow is directed equally to both legs, similar levels of oxygen extraction (as indicated by SmO2) suggests the metabolic load of

  19. Effects of Changes in Arterial Carbon Dioxide and Oxygen Partial Pressures on Cerebral Oximeter Performance.

    Science.gov (United States)

    Schober, Andrew; Feiner, John R; Bickler, Philip E; Rollins, Mark D

    2018-01-01

    Cerebral oximetry (cerebral oxygen saturation; ScO2) is used to noninvasively monitor cerebral oxygenation. ScO2 readings are based on the fraction of reduced and oxidized hemoglobin as an indirect estimate of brain tissue oxygenation and assume a static ratio of arterial to venous intracranial blood. Conditions that alter cerebral blood flow, such as acute changes in PaCO2, may decrease accuracy. We assessed the performance of two commercial cerebral oximeters across a range of oxygen concentrations during normocapnia and hypocapnia. Casmed FORE-SIGHT Elite (CAS Medical Systems, Inc., USA) and Covidien INVOS 5100C (Covidien, USA) oximeter sensors were placed on 12 healthy volunteers. The fractional inspired oxygen tension was varied to achieve seven steady-state levels including hypoxic and hyperoxic PaO2 values. ScO2 and simultaneous arterial and jugular venous blood gas measurements were obtained with both normocapnia and hypocapnia. Oximeter bias was calculated as the difference between the ScO2 and reference saturation using manufacturer-specified weighting ratios from the arterial and venous samples. FORE-SIGHT Elite bias was greater during hypocapnia as compared with normocapnia (4 ± 9% vs. 0 ± 6%; P oxygen saturation and mixed venous oxygen tension, as well as increased oxygen extraction across fractional inspired oxygen tension levels (P oxygen extraction (P < 0.0001). Changes in PaCO2 affect cerebral oximeter accuracy, and increased bias occurs with hypocapnia. Decreased accuracy may represent an incorrect assumption of a static arterial-venous blood fraction. Understanding cerebral oximetry limitations is especially important in patients at risk for hypoxia-induced brain injury, where PaCO2 may be purposefully altered.

  20. Comparison between fluorimetry and oximetry techniques to measure photosynthesis in the diatom Skeletonema costatum cultivated under simulated seasonal conditions.

    Science.gov (United States)

    Lefebvre, Sébastien; Mouget, Jean-Luc; Loret, Pascale; Rosa, Philippe; Tremblin, Gérard

    2007-02-01

    This study reports comparison of two techniques measuring photosynthesis in the ubiquitous diatom Skeletonema costatum, i.e., the classical oximetry and the recent modulated fluorimetry. Microalgae in semi-continuous cultures were exposed to five different environmental conditions simulating a seasonal effect with co-varying temperature, photoperiod and incident light. Photosynthesis was assessed by gross rate of oxygen evolution (P(B)) and the electron transport rate (ETR) measurements. The two techniques were linearly related within seasonal treatments along the course of the P/E curves. The light saturation intensity parameters (Ek and Ek(ETR)), and the maximum electron transport rate increased significantly with the progression of the season while the maximum light utilization efficiency for ETR (alpha(ETR)) was constant. By contrast, the maximum gross oxygen photosynthetic capacity (Pmax(B)) and the maximum light utilization efficiency for P(B) (alpha(B)) increased from December to May treatment but decreased from May to July treatment. Both techniques showed clear photoacclimation in microalgae with the progression of the season, as illustrated by changes in photosynthetic parameters. The relationship between the two techniques changed when high temperature, photoperiod and incident light were combined, possibly due to an overestimation of the PAR--averaged chlorophyll-specific absorption cross-section. Despite this change, our results illustrate the strong suitability of in vivo chlorophyll fluorimetry to estimate primary production in the field.

  1. The 30-second rule: the effects of prolonged intubation attempts on oxygen saturation and heart rate in preterm infants in the delivery room.

    Science.gov (United States)

    Wozniak, Madeline; Arnell, Kathy; Brown, Melissa; Gonzales, Sarah; Lazarus, Danielle; Rich, Wade; Katheria, Anup

    2018-04-01

    A duration of 30 seconds has been shown to improve the success rate of intubation attempts without any decompensation. There is limited data regarding the detrimental effects of prolonged intubation attempts in preterm infants. The aim was to determine the effect of prolonged intubation attempts on heart rate and oxygen saturation in preterm infants. We retrospectively reviewed videos and physiologic data collected during delivery room (DR) resuscitations. Infants who had a functioning pulse oximeter at the time of intubation in the delivery room were analyzed using video and analog recordings. The duration of the intubation attempt was defined as the time the laryngoscope blade was in the infant's mouth. Prolonged intubations were defined as intubations over 30 seconds. Baseline heart rate and saturations were defined as the heart rate and saturation immediately prior to the intubation attempt. Video recording was used to determine time laryngoscope was in the mouth, what other procedures were performed, and whether there was recovery between attempts. Analog data including heart rate, airway pressure and saturation was also recorded. There were 52 intubation attempts in 28 infants. The median (IQR) birth weight and gestational age were 795 (705, 972) grams and 25 (25, 27) weeks. The duration of an intubation attempt was 35 (27, 46) seconds with number of attempts 2 (1, 2). There were 34 intubation attempts greater than 30 seconds (prolonged group) and 18 attempts less than or equal to 30 seconds (short group). Longer attempts did not affect intubation success (successful 34 [25,37] seconds vs. unsuccessful 41[29, 53] seconds; P=0.05). Infants in the prolonged group had a greater decrease in oxygen saturation percentage from baseline (5±8 percent, short intubation group and 13±27 prolonged intubation group; P=0.004). There was also a significant decrease in heart rate beats per minute between the two groups (6±9 in the short intubation group and 23±29

  2. Oxygen Saturation Surrounding Deep Water Formation Events in the Labrador Sea From Argo-O2 Data

    Science.gov (United States)

    Wolf, Mitchell K.; Hamme, Roberta C.; Gilbert, Denis; Yashayaev, Igor; Thierry, Virginie

    2018-04-01

    Deep water formation supplies oxygen-rich water to the deep sea, spreading throughout the ocean by means of the global thermohaline circulation. Models suggest that dissolved gases in newly formed deep water do not come to equilibrium with the atmosphere. However, direct measurements during wintertime convection are scarce, and the controls over the extent of these disequilibria are poorly quantified. Here we show that, when convection reached deeper than 800 m, oxygen in the Labrador Sea was consistently undersaturated at -6.1% to -7.6% at the end of convection. Deeper convection resulted in greater undersaturation, while convection ending later in the year resulted in values closer to equilibrium, from which we produce a predictive relationship. We use dissolved oxygen data from six profiling Argo floats in the Labrador Sea between 2003 and 2016, allowing direct observations of wintertime convection. Three of the six optode oxygen sensors displayed substantial average in situ drift of -3.03 μmol O2 kg-1 yr-1 (-0.94% O2 yr-1), which we corrected to stable deepwater oxygen values from repeat ship surveys. Observations of low oxygen intrusions during restratification and a simple mixing calculation demonstrate that lateral processes act to lower the oxygen inventory of the central Labrador Sea. This suggests that the Labrador Sea is a net sink for atmospheric oxygen, but uncertainties in parameterizing gas exchange limit our ability to quantify the net uptake. Our results constrain the oxygen concentration of newly formed Labrador Sea Water and allow more precise estimates of oxygen utilization and nutrient regeneration in this water mass.

  3. Comparison of oxygen saturation levels in patients receiving Technegas by the conventional unassisted method vs. the positive ventilation delivery system (PVDS)

    International Nuclear Information System (INIS)

    Dobson, M.P.; Leiper, C.A.; Lee, K.; Dixson, H.

    2000-01-01

    Full text: The purpose of this study is to compare oxygen saturation levels (SaO 2 ) in 289 patients undergoing conventional lung ventilation scintigraphy (control group) and 27 patients undergoing Positive Ventilation Delivery System (PVDS). The 27 patients where selected as their conventional method of inhalation proved to be inadequate or non-diagnostic. The patients underwent a second ventilation using PVDS, which improved the diagnostic quality of the ventilation image and assisted in clinical management decisions. Some patients in both the PVDS and the control group experienced a transient lowering in their SaO 2 . The mean initial SaO 2 in the control group did not fall below 94.9% and in the PVDS group measured 90.6%. 93% (25/27) of patients in the PVDS group were assessed as non CO 2 retaining, and received oxygen at 10L/min during Technegas inhalation. The mean trough saturation in the PVDS group was 91.7% which was significantly higher than that of the control group (86.9%). No patient in either group experienced any significant complication attributed to the transient tall in SaO 2 during technegas administration. We conclude that oxygen supplied as part of the PVDS system ameliorates the transient reduction in SaO 2 seen during standard Technegas administration. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  4. The effects of arterial carbon dioxide partial pressure and sevoflurane on capillary venous cerebral blood flow and oxygen saturation during craniotomy.

    Science.gov (United States)

    Klein, Klaus Ulrich; Glaser, Martin; Reisch, Robert; Tresch, Achim; Werner, Christian; Engelhard, Kristin

    2009-07-01

    Intraoperative routine monitoring of cerebral blood flow and oxygenation remains a technological challenge. Using the physiological principle of carbon dioxide reactivity of cerebral vasculature, we investigated a recently developed neuromonitoring device (oxygen-to-see, O2C device) for simultaneous measurements of regional cerebral blood flow (rvCBF), blood flow velocity (rvVelo), oxygen saturation (srvO2), and hemoglobin amount (rvHb) at the capillary venous level in patients subjected to craniotomy. Twenty-six neurosurgical patients were randomly assigned to anesthesia with 1.4% or 2.0% sevoflurane end-tidal concentration. After craniotomy, a fiberoptic probe was applied on a macroscopically healthy surface of cerebral tissue next to the site of surgery. Simultaneous measurements in 2 and 8 mm cerebral depth were performed in each patient during lower (35 mm Hg) and higher (45 mm Hg) levels (random order) of arterial carbon dioxide partial pressure (PaCO2). The principle of these measurements relies on the combination of laser-Doppler flowmetry (rvCBF, rvVelo) and photo-spectrometry (srvO2, rvHb). Linear models were fitted to test changes of end points (rvCBF, rvVelo, srvO2, rvHb) in response to lower and higher levels of PaCO2, 1.4% and 2.0% sevoflurane end-tidal concentration, and 2 and 8 mm cerebral depth. RvCBF and rvVelo were elevated by PaCO2 independent of sevoflurane concentration in 2 and 8 mm depth of cerebral tissue (P oxygen was decreased by elevated PaCO2. Unchanged levels of rvHb signify that there was no blood loss during measurements. Data suggest that the device allows detection of local changes in blood flow and oxygen saturation in response to different PaCO2 levels in predominant venous cerebral microvessels.

  5. Barley seed radiosensitivity following post-hydration in oxygen-, nitrogen- and nitrous oxide-saturated water, 1

    International Nuclear Information System (INIS)

    Singh, S.P.; Kesavan, P.C.

    1990-01-01

    Dry (∼3.5 and 4.0 per cent moisture content) barley seeds were exposed to 350 Gy of 60 Co-γ-rays in vacuo and post-hydrated at 4degC for 8 h in O 2 -, N 2 -, or N 2 O-saturated water. The effect of caffeine and t-butyl alcohol (t-BuOH) dissolved in the post-hydration medium on the magnitude of damage developing under these three different gaseous circumstances was studied. The post-irradiation damage and its modification by caffeine and t-BuOH was assessed in terms of 8-day-old seedling injury, peroxidase activity and total peroxides in the 8-day-old seedlings. Post-irradiation O 2 -saturated hydration caused maximal 8-day-old seedling injury, and increased peroxidase activity with concomitant reduction in total peroxides. Both caffeine and t-BuOH afforded significant radioprotection against post-irradiation O 2 -dependent damage. Post-irradiation N 2 O-saturated hydration was even more significantly radioprotective than the N 2 -saturated post-hydration. Under these circumstances, t-BuOH exerted no effect whatsoever on the N 2 - and N 2 O-mediated post-irradiation damage. Caffeine, on the other hand, significantly potentiated these two components of damage. A brief consideration of the physicochemical events which possibly account for the observed effects is presented. (author)

  6. Calibration-free technique for the measurement of oxygen saturation changes in muscles of marine mammals and its proof of concept

    Science.gov (United States)

    Ortega-Martinez, Antonio; Goenka, Chhavi; Booker, Marloes; Grange, Robert M. H.; Hindle, Allyson G.; Franco, Walfre

    2018-02-01

    Marine mammals possess impressive breath-holding capabilities made possible by physiological adjustments during dives. Studying marine mammals in their natural environment unravels vital information about these physiological adjustments particularly when we can monitor altered dive behavior in response to stressful situations such as human-induced oceanic disturbances, presence of predators and altered prey distributions. An important indicator of physiological status during submergence is the change in oxygen saturation in the muscles and blood of these mammals. In this work, we aim to investigate oxygen storage and consumption in the muscles of free-diving elephant seals when exposed to disturbances such as sonar or predator sounds while they are at sea. Optical oxygen sensors are a mature technology with multiple medical applications that provide a way to measure oxygenation changes in biological tissues in a minimally invasive manner. While these sensors are well calibrated and readily available for humans, they are still inadequate for marine mammals primarily due to a very small number of test candidates and therefore little data is available for validation and calibration. We propose a probe geometry and associated mathematical model for measuring muscle oxygenation in seals based on near infrared diffuse transport with no need for calibration. A prototype based on this concept has been designed and tested on humans and rats. We use the test results to discuss the advantages and limitations of the approach. We also detail the constraints on size, sensor location, electronics, light source properties and detector characteristics posed by the unique biology of seals.

  7. [Study of blood oxygen saturation, heart rate changes and plateau reaction of the Antarctic Kunlun station investigation team in different plateau environments].

    Science.gov (United States)

    Zhao, Shun-yun; Wu, Xin-min; Guo, Ya-min; Zhang, Shu-shun; An, Yan-ming; Li, Bing; Wang, Hao

    2013-06-11

    To explore the blood oxygen saturation and heart rate changes of the Antarctic explorers. During August 2010 to April 2011, the changes in blood oxygen saturation, heart rate and plateau reaction of 16 Antarctic expedition team in different plateau environments (Tibetan plateau versus Antarctic plateau) were monitored with the noninvasive pulse oximeter MD300-C. The extent of acute mountain sickness was determined according to the Lake Louise Consensus acute mountain reaction symptom scores and judgment method. The changes of blood oxygen saturation, heart rate at different altitudes of 110, 3650, 4300 m (96.8% ± 1.2%,89.1% ± 1.2%, 86.1% ± 2.0%, (75.0 ± 5.4) times/min, (104.0 ± 4.3) times/min, (113.0 ± 5.2) times/min,F = 214.155, 240.088,both P rate at different altitudes of 2000, 2500, 3000, 3500 and 4087 m(91.9% ± 1.3%,90.5% ± 1.3%,87.6% ± 1.4%,85.0% ± 1.8%,81.5% ± 2.2%, (85.9 ± 3.2) times/min, (90.6 ± 2.8) times/min, (97.8 ± 4.1) times/min, (102.0 ± 3.4) times/min, (106.3 ± 3.9) times/min, F = 105.418, 90.174, both P rate were both correlated with the risk of altitude sickness (r = -0.446 and 0.565, both P rate of the Antarctic explorers. And with the increases of altitude, the risk of altitude sickness gradually increases.

  8. Association between minor loading vein architecture and light- and CO2-saturated rates of photosynthetic oxygen evolution among Arabidopsis thaliana ecotypes from different latitudes

    Directory of Open Access Journals (Sweden)

    Christopher M Cohu

    2013-07-01

    Full Text Available Through microscopic analysis of veins and assessment of light- and CO2-saturated rates of photosynthetic oxygen evolution, we investigated the relationship between minor loading vein anatomy and photosynthesis of mature leaves in three ecotypes of Arabidopsis thaliana grown under four different combinations of temperature and photon flux density (PFD. All three ecotypes exhibited greater numbers and cross-sectional area of phloem cells as well as higher photosynthesis rates in response to higher PFD and especially lower temperature. The Swedish ecotype exhibited the strongest response to these conditions, the Italian ecotype the weakest response, and the Col-0 ecotype exhibited an intermediate response. Among all three ecotypes, strong linear relationships were found between light- and CO2-saturated rates of photosynthetic oxygen evolution and the number and area of either sieve elements or of companion and phloem parenchyma cells in foliar minor loading veins, with the Swedish ecotype showing the highest number of cells in minor loading veins (and largest minor veins coupled with unprecedented high rates of photosynthesis. Linear, albeit less significant, relationships were also observed between number and cross-sectional area of tracheids per minor loading vein versus light- and CO2-saturated rates of photosynthetic oxygen evolution. We suggest that sugar distribution infrastructure in the phloem is co-regulated with other features that set the upper limit for photosynthesis. The apparent genetic differences among Arabidopsis ecotypes should allow for future identification of the gene(s involved in augmenting sugar-loading and -transporting phloem cells and maximal rates of photosynthesis.

  9. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges

    OpenAIRE

    Abay, T. Y.; Kyriacou, P. A.

    2016-01-01

    © 2016 Institute of Physics and Engineering in Medicine. Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of...

  10. Corrosion behavior of austenitic and ferritic/martensitic steels in oxygen-saturated liquid Pb-Bi eutectic at 450circC and 550circC

    OpenAIRE

    倉田 有司; 二川 正敏; 斎藤 滋

    2005-01-01

    Static corrosion tests of various austenitic and ferritic/martensitic steels were conducted in oxygen-saturated liquid Pb-Bi at 450circC and 550circC for 3000h to study the effects of temperature and alloying elements on corrosion behavior. Oxidation, grain boundary corrosion, dissolution and penetration were observed. The corrosion depth decreases at 450circC with increasing Cr content in steels regardless of ferritic/martensitic or austenitic steels. Appreciable dissolution of Ni and Cr doe...

  11. Improved Apnea-Hypopnea Index and Lowest Oxygen Saturation After Maxillomandibular Advancement With or Without Counterclockwise Rotation in Patients With Obstructive Sleep Apnea

    DEFF Research Database (Denmark)

    Knudsen, Torben B.; Laulund, Anne Sofie; Ingerslev, Janne

    2015-01-01

    - and postsurgical values of pharyngeal volume measured on computed tomogram or cone-beam computed tomogram and changes in Apnea-Hypopnea Index (AHI) and lowest oxygen saturation (LSAT) values after surgery. Datawere subjected to a meta-analysis based on odds ratios (OR) with 95% confidence intervals (CIs) and P...... between pharyngeal volume changes and surgical method used. Postoperative parameters included an AHI lower than 5 (OR = 14.9; 95% CI, 2.7-83.5; P = .002), an AHI lower than 20 (OR = 114.8; 95% CI, 23.5-561.1; P

  12. Correlation between near-infrared spectroscopy and magnetic resonance imaging of rat brain oxygenation modulation

    International Nuclear Information System (INIS)

    Chen Yu; Tailor, Dharmesh R; Intes, Xavier; Chance, Britton

    2003-01-01

    We measure the tissue oxygen and haemoglobin concentrations in the rat brain during modulation of inhaled oxygen concentration (FiO 2 ), using non-invasive frequency domain near-infrared oximetry. The rise in oxygenated haemoglobin concentration and the decline in deoxygenated haemoglobin concentration are demonstrated in correspondence with the modulation of FiO 2 , which is changed from 20% to 100% in increments of 20%. Furthermore, the tissue oxygenation saturation also shows the corresponding trend and changes ranging from approximately 70% to 90%. The relative changes in deoxygenated haemoglobin concentration are compared to the blood-oxygenation-level-dependent (BOLD) MRI signal recorded during a similar FiO 2 protocol. A linear relationship with high correlation coefficient between the relative changes in the BOLD MRI signal and the NIRS signal is observed

  13. Correlation between near-infrared spectroscopy and magnetic resonance imaging of rat brain oxygenation modulation

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yu [Department of Biochemistry and Biophysics, University of Pennsylvania, Philadelphia, PA (United States); Tailor, Dharmesh R [Department of Bioengineering, University of Pennsylvania, Philadelphia, PA (United States); Intes, Xavier [Department of Biochemistry and Biophysics, University of Pennsylvania, Philadelphia, PA (United States); Chance, Britton [Department of Biochemistry and Biophysics, University of Pennsylvania, Philadelphia, PA (United States)

    2003-02-21

    We measure the tissue oxygen and haemoglobin concentrations in the rat brain during modulation of inhaled oxygen concentration (FiO{sub 2}), using non-invasive frequency domain near-infrared oximetry. The rise in oxygenated haemoglobin concentration and the decline in deoxygenated haemoglobin concentration are demonstrated in correspondence with the modulation of FiO{sub 2}, which is changed from 20% to 100% in increments of 20%. Furthermore, the tissue oxygenation saturation also shows the corresponding trend and changes ranging from approximately 70% to 90%. The relative changes in deoxygenated haemoglobin concentration are compared to the blood-oxygenation-level-dependent (BOLD) MRI signal recorded during a similar FiO{sub 2} protocol. A linear relationship with high correlation coefficient between the relative changes in the BOLD MRI signal and the NIRS signal is observed.

  14. In-vivo quantitative measurement of tissue oxygen saturation of human webbing using a transmission type continuous-wave near-infrared spectroscopy

    Science.gov (United States)

    Aizimu, Tuerxun; Adachi, Makoto; Nakano, Kazuya; Ohnishi, Takashi; Nakaguchi, Toshiya; Takahashi, Nozomi; Nakada, Taka-aki; Oda, Shigeto; Haneishi, Hideaki

    2018-02-01

    Near-infrared spectroscopy (NIRS) is a noninvasive method for monitoring tissue oxygen saturation (StO2). Many commercial NIRS devices are presently available. However, the precision of those devices is relatively poor because they are using the reflectance-model with which it is difficult to obtain the blood volume and other unchanged components of the tissue. Human webbing is a thin part of the hand and suitable to measure spectral transmittance. In this paper, we present a method for measuring StO2 of human webbing from a transmissive continuous-wave nearinfrared spectroscopy (CW-NIRS) data. The method is based on the modified Beer-Lambert law (MBL) and it consists of two steps. In the first step, we give a pressure to the upstream region of the measurement point to perturb the concentration of deoxy- and oxy-hemoglobin as remaining the other components and measure the spectral signals. From the measured data, spectral absorbance due to the components other than hemoglobin is calculated. In the second step, spectral measurement is performed at arbitrary time instance and the spectral absorbance obtained in the step 1 is subtracted from the measured absorbance. The tissue oxygen saturation (StO2) is estimated from the remained data. The method was evaluated on an arterial occlusion test (AOT) and a venous occlusion test (VOT). In the evaluation experiment, we confirmed that reasonable values of StO2 were obtained by the proposed method.

  15. Baseline cerebral oximetry values depend on non-modifiable patient characteristics.

    Science.gov (United States)

    Valencia, Lucía; Rodríguez-Pérez, Aurelio; Ojeda, Nazario; Santana, Romen Yone; Morales, Laura; Padrón, Oto

    2015-12-01

    The aim of the present study was to evaluate baseline regional cerebral oxygen saturation (rSO2) values and identify factors influencing preoperative rSO2 in elective minor surgery. Observational analysis post-hoc. Observational post-hoc analysis of data for the patient sample (n=50) of a previously conducted clinical trial in patients undergoing tumourectomy for breast cancer or inguinal hernia repair. Exclusion criteria included pre-existing cerebrovascular diseases, anaemia, baseline pulse oximetry values were recorded while the patient breathed room air, using the INVOS 5100C monitor™ (Covidien, Dublin, Ireland). Thirty-seven women (72%) and 13 men (28%) 48 ± 13 years of age were enrolled in this study. Baseline rSO2 was 62.01 ± 10.38%. Baseline rSO2 was significantly different between men (67.6 ± 11.2%) and women (60 ± 9.4%), (P=0.023). There were also differences between baseline rSO2 and ASA physical status (ASA I: 67.6 ± 10.7%, ASA II: 61.6 ± 8.4%, ASA III: 55.8 ± 13.9%, P=0.045). Baseline rSO2 had a positive correlation with body weight (r=0.347, P=0.014) and height (r=0.345, P=0.014). We also found significant differences in baseline rSO2 among patients with and without chronic renal failure (P=0.005). No differences were found in any other studied variables. Non-modifiable patient characteristics (ASA physical status, sex, chronic renal failure, body weight and height) influence baseline rSO2. Copyright © 2015 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  16. Detecting obstructive sleep apnea in children by self-affine visualization of oximetry.

    Science.gov (United States)

    Garde, Ainara; Dekhordi, Parastoo; Petersen, Christian L; Ansermino, J Mark; Dumont, Guy A

    2017-07-01

    Obstructive sleep apnea (OSA), characterized by cessations of breathing during sleep due to upper airway collapse, can affect the healthy growth and development of children. The gold standard for OSA diagnosis, polysomnography(PSG), is expensive and resource intensive, resulting in long waiting lists to perform a PSG. Previously, we investigated the time-frequency analysis of blood oxygen saturation (SpO 2 ) to screen for OSA. We used overnight pulse oximetry from 146 children, collected using a smartphone-based pulse oximeter (Phone Oximeter), simultaneously with standard PSG. Sleep technicians manually scored PSG and provided the average of apnea/hypoapnea events per hour (AHI). In this study, we proposed an alternative method for analyzing SpO 2 , in which a set of contracting transformations form a self-affine set with a 2D attractor, previously developed for qualitative visualization of the photoplethysmogram and electroencephalogram. We applied this technique to the overnight SpO 2 signal from individual patients and extracted features based on the distribution of points (radius and angle) in the visualization. The cloud of points in children without OSA (NonOSA) was more confined than in children with OSA, which was reflected by more empty pixels (radius and angles). The maximum value, skewness and standard deviation of the distribution of points located at different radius and angles were significantly (Bonferroni corrected) higher in NonOSA compared to OSA children. To detect OSA defined at different levels (AHI≥5, AHI≥10 and AHI≥15), three multivariate logistic regression models were implemented using a stepwise feature selection and internally validated through bootstrapping. The models (AHI≥5, AHI≥10, AHI≥15), consisting of 3, 4 and 1 features respectively, provided a bootstrap-corrected AUC of 73%, 81%, 73%. Thus, applying this visualization to nocturnal SpO 2 could yield both visual and quantitative information that might be useful for

  17. SU-E-T-326: The Oxygen Saturation (SO2) and Breath-Holding Time Variation Applied Active Breathing Control (ABC)

    Energy Technology Data Exchange (ETDEWEB)

    Gong, G; Yin, Y [Shandong Cancer Hospital, Jinan, Shandong (China)

    2014-06-01

    Purpose: To study the oxygen saturation (SO2) and breath-holding time variation applied active breathing control (ABC) in radiotherapy of tumor. Methods: 24 volunteers were involved in our trials, and they all did breath-holding motion assisted by ELEKTA Active Breathing Coordinator 2.0 for 10 times respectively. And the patient monitor was used to observe the oxygen saturation (SO2) variation. The variation of SO2, and length of breath-holding time and the time for recovering to the initial value of SO2 were recorded and analyzed. Results: (1) The volunteers were divided into two groups according to the SO2 variation in breath-holding: A group, 14 cases whose SO2 reduction were more than 2% (initial value was 97% to 99%, while termination value was 91% to 96%); B group, 10 cases were less than 2% in breath-holding without inhaling oxygen. (2) The interfraction breath holding time varied from 8 to 20s for A group compared to the first breath-holding time, and for B group varied from 4 to 14s. (3) The breathing holding time of B group prolonged mean 8s, compared to A group. (4) The time for restoring to the initial value of SO2 was from 10s to 30s. And the breath-holding time shortened obviously for patients whose SO2 did not recover to normal. Conclusion: It is very obvious that the SO2 reduction in breath-holding associated with ABC for partial people. It is necessary to check the SO2 variation in breath training, and enough time should be given to recover SO2.

  18. Single-cell measurement of red blood cell oxygen affinity.

    Science.gov (United States)

    Di Caprio, Giuseppe; Stokes, Chris; Higgins, John M; Schonbrun, Ethan

    2015-08-11

    Oxygen is transported throughout the body by hemoglobin (Hb) in red blood cells (RBCs). Although the oxygen affinity of blood is well-understood and routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of RBC volume and Hb concentration are taken millions of times per day by clinical hematology analyzers, and they are important factors in determining the health of the hematologic system. To better understand the variability and determinants of oxygen affinity on a cellular level, we have developed a system that quantifies the oxygen saturation, cell volume, and Hb concentration for individual RBCs in high throughput. We find that the variability in single-cell saturation peaks at an oxygen partial pressure of 2.9%, which corresponds to the maximum slope of the oxygen-Hb dissociation curve. In addition, single-cell oxygen affinity is positively correlated with Hb concentration but independent of osmolarity, which suggests variation in the Hb to 2,3-diphosphoglycerate (2-3 DPG) ratio on a cellular level. By quantifying the functional behavior of a cellular population, our system adds a dimension to blood cell analysis and other measurements of single-cell variability.

  19. Electron paramagnetic resonance and dynamic nuclear polarization of char suspensions: surface science and oximetry

    International Nuclear Information System (INIS)

    Clarkson, R.B.; Odintsov, B.M.; Ceroke, P.J.; Ardenkjaer-Larsen, J.H.; Fruianu, M.; Belford, R.L.

    1998-01-01

    Carbon chars have been synthesized in our laboratory from a variety of starting materials, by means of a highly controlled pyrolysis technique. These chars exhibit electron paramagnetic resonance (EPR) line shapes which change with the local oxygen concentration in a reproducible and stable fashion; they can be calibrated and used for oximetry. Biological stability and low toxicity make chars good sensors for in vivo measurements. Scalar and dipolar interactions of water protons at the surfaces of chars may be utilized to produce dynamic nuclear polarization (DNP) of the 1 H nuclear spin population in conjunction with electron Zeeman pumping. Low-frequency EPR, DNP and DNP-enhanced MRI all show promise as oximetry methods when used with carbon chars. (author)

  20. Safety in the use of compressed air versus oxygen for the ophthalmic patient.

    Science.gov (United States)

    Rodgers, Laura A; Kulwicki, Anahid

    2002-02-01

    Oxygen, routinely administered during surgery to avoid hypoxia, poses risks including increased likelihood of surgical room fires and predisposition to retinal phototoxicity in patients. Compressed air to supplement ventilation may be safer than oxygen. The purpose of this study was to determine whether hypoxia occurs more frequently when compressed air replaces supplemental oxygen during ophthalmic surgery. A convenience sample of 111 patients was randomly assigned to receive supplemental oxygen (group 1) or compressed air (group 2). Patients with serious cardiac or pulmonary disease were excluded. Blood oxygen levels were monitored during surgery by pulse oximetry. Oxygen was administered to all group 2 patients whose oxygen saturation fell to less than 90% or by more than 5% below baseline. No differences were observed between groups in age, ASA classification, type of surgery, or anesthetic drugs or doses. Minor, but statistically higher oxygen values were observed in group 1. The frequency with which oxygen saturation decreased below 90% or below 5% of baseline was similar in both groups. Supplemental oxygen is not required routinely in selected patients undergoing ophthalmic surgery. By using compressed air, the risk of operating room fires and retinal phototoxicity may be reduced.

  1. A general model to calculate the spin-lattice (T1) relaxation time of blood, accounting for haematocrit, oxygen saturation and magnetic field strength.

    Science.gov (United States)

    Hales, Patrick W; Kirkham, Fenella J; Clark, Christopher A

    2016-02-01

    Many MRI techniques require prior knowledge of the T1-relaxation time of blood (T1bl). An assumed/fixed value is often used; however, T1bl is sensitive to magnetic field (B0), haematocrit (Hct), and oxygen saturation (Y). We aimed to combine data from previous in vitro measurements into a mathematical model, to estimate T1bl as a function of B0, Hct, and Y. The model was shown to predict T1bl from in vivo studies with a good accuracy (± 87 ms). This model allows for improved estimation of T1bl between 1.5-7.0 T while accounting for variations in Hct and Y, leading to improved accuracy of MRI-derived perfusion measurements. © The Author(s) 2015.

  2. Laser Doppler imaging, thermographic imaging, and tissue oxygen saturation measurements detect early skin reactions during breast radiotherapy

    Science.gov (United States)

    Harrison, David K.; Harrison, Eileen M.; Newton, David J.; Windsor, Phyllis M.

    2001-05-01

    A range of acute skin reactions, ranging from mild erythema to moist desquamation, can be seen in patients receiving standard fractionated radiotherapy to the breast for conservation therapy of breast carcinoma. In a number of cases these reactions can cause considerable discomfort and seriously affect the patient's quality of life. In previous studies we have used the techniques of laser Doppler imaging, digital thermographic imaging and lightguide spectrophotometry to study oxygen supply and blood flow in inflammatory reactions induced experimentally in forearm skin. The present study is an attempt to use the same techniques to investigate whether any or all of them can detect changes in breast skin very early on in the course of radiotherapy treatment. A further aim of the longer term study is to investigate to what extent these early changes may be able to predict the occurrence later of severe acute or delayed reactions.

  3. Vitamin D Depletion in Pregnancy Decreases Survival Time, Oxygen Saturation, Lung Weight and Body Weight in Preterm Rat Offspring

    DEFF Research Database (Denmark)

    Lykkedegn, Sine; Sorensen, Grith Lykke; Beck-Nielsen, Signe Sparre

    2016-01-01

    Animal studies suggest a role of vitamin D in fetal lung development although not studied in preterm animals. We tested the hypothesis that vitamin D depletion aggravates respiratory insufficiency in preterm rat offspring. Furthermore, the effects of vitamin D depletion on growth and lung...... surfactant were investigated. Female Sprague-Dawley rats were randomly assigned low vitamin D (VDL) or control diet before mating and followed with serum 25-hydroxyvitamin D (s-25(OH)D) determinations. After cesarean section at gestational day 19 (E19) or day 22 (E22), placental weight, birth weight, crown......-rump-length (CRL), oxygenation (SaO2) at 30 min and survival time were recorded. The pup lungs were analyzed for phospholipid levels, surfactant protein A-D mRNA and the expression of the vitamin D receptor (VDR). S-25(OH)D was significantly lower in the VDL group at cesarean section (12 vs. 30nmol/L, p

  4. Vitamin D Depletion in Pregnancy Decreases Survival Time, Oxygen Saturation, Lung Weight and Body Weight in Preterm Rat Offspring.

    Directory of Open Access Journals (Sweden)

    Sine Lykkedegn

    Full Text Available Animal studies suggest a role of vitamin D in fetal lung development although not studied in preterm animals. We tested the hypothesis that vitamin D depletion aggravates respiratory insufficiency in preterm rat offspring. Furthermore, the effects of vitamin D depletion on growth and lung surfactant were investigated. Female Sprague-Dawley rats were randomly assigned low vitamin D (VDL or control diet before mating and followed with serum 25-hydroxyvitamin D (s-25(OHD determinations. After cesarean section at gestational day 19 (E19 or day 22 (E22, placental weight, birth weight, crown-rump-length (CRL, oxygenation (SaO2 at 30 min and survival time were recorded. The pup lungs were analyzed for phospholipid levels, surfactant protein A-D mRNA and the expression of the vitamin D receptor (VDR. S-25(OHD was significantly lower in the VDL group at cesarean section (12 vs. 30nmol/L, p<0.0001. Compared to the controls, E19 VDL pups had lower birth weight (2.13 vs. 2.29g, p<0.001, lung weight (0.09 vs. 0.10g, p = 0.002, SaO2 (54% vs. 69%, p = 0.002 as well as reduced survival time (0.50 vs. 1.25h, p<0.0001. At E22, the VDL-induced pulmonary differences were leveled out, but VDL pups had lower CRL (4.0 vs. 4.5cm, p<0.0001. The phospholipid levels and the surfactant protein mRNA expression did not differ between the dietary groups. In conclusion, Vitamin D depletion led to lower oxygenation and reduced survival time in the preterm offspring, associated with reduced lung weight and birth weight. Further studies of vitamin D depletion in respiratory insufficiency in preterm neonates are warranted.

  5. Fiberoptic monitoring of central venous oxygen saturation (PediaSat in small children undergoing cardiac surgery: continuous is not continuous [v3; ref status: indexed, http://f1000r.es/3qt

    Directory of Open Access Journals (Sweden)

    Francesca G. Iodice

    2014-06-01

    Full Text Available Background: Monitoring of superior vena cava saturation (ScvO2 has become routine in the management of pediatric patients undergoing cardiac surgery. The objective of our study was to evaluate the correlation between continuous ScvO2 by the application of a fiber-optic oximetry catheter (PediaSat and intermittent ScvO2 by using standard blood gas measurements. These results were compared to those obtained by cerebral near infrared spectroscopy (cNIRS. Setting: Tertiary pediatric cardiac intensive care unit (PCICU. Methods and main results: A retrospective study was conducted in consecutive patients who were monitored with a 4.5 or 5.5 F PediaSat catheter into the right internal jugular vein. An in vivo calibration was performed once the patient was transferred to the PCICU and re-calibration took place every 24 hours thereafter. Each patient had a NIRS placed on the forehead. Saturations were collected every 4 hours until extubation. Ten patients with a median age of 2.2 (0.13-8.5 years and a weight of 12.4 (3.9-24 kg were enrolled. Median sampling time was 32 (19-44 hours: 64 pairs of PediaSat and ScVO2 saturations showed a poor correlation (r=0.62, 95% CI 44-75; p<0.0001 and Bland Altman analysis for repeated measures showed an average difference of 0.34 with a standard deviation of 7,9 and 95% limits of agreement from -15 to 16. Thirty-six pairs of cNIRS and ScVO2 saturations showed a fair correlation (r=0.79, 95% CI 0.60-0.89; p<0.0001 an average difference of -1.4 with a standard deviation of 6 and 95% limits of agreement from -13 to 10. Analysis of median percentage differences between PediaSat and ScvO2 saturation over time revealed that, although not statistically significant, the change in percentage saturation differences was clinically relevant after the 8th hour from calibration (from -100 to +100%. Conclusion: PediaSat catheters showed unreliable performance in our cohort. It should be further investigated whether repeating

  6. Pulse oximetry: a potential aid in endodontic diagnosis?

    Science.gov (United States)

    Caplan, Dan

    2010-06-01

    Pulse oximetry: review of a potential aid in endodontic diagnosis. Jafarzadeh H, Rosenberg PA. J Endod 2009;35(3):329-33. Dan Caplan, DDS, PhD. This article provided a description of pulse oximetry, its use in patient care settings, and its potential for use in endodontic diagnosis. Information not available. Comprehensive literature review. Level 3: Other evidence. Not applicable.

  7. Carbon dioxide narcosis due to inappropriate oxygen delivery: a case report.

    Science.gov (United States)

    Herren, Thomas; Achermann, Eva; Hegi, Thomas; Reber, Adrian; Stäubli, Max

    2017-07-28

    Oxygen delivery to patients with chronic obstructive pulmonary disease may be challenging because of their potential hypoxic ventilatory drive. However, some oxygen delivery systems such as non-rebreathing face masks with an oxygen reservoir bag require high oxygen flow for adequate oxygenation and to avoid carbon dioxide rebreathing. A 72-year-old Caucasian man with severe chronic obstructive pulmonary disease was admitted to the emergency department because of worsening dyspnea and an oxygen saturation of 81% measured by pulse oximetry. Oxygen was administered using a non-rebreathing mask with an oxygen reservoir bag attached. For fear of removing the hypoxic stimulus to respiration the oxygen flow was inappropriately limited to 4L/minute. The patient developed carbon dioxide narcosis and had to be intubated and mechanically ventilated. Non-rebreathing masks with oxygen reservoir bags must be fed with an oxygen flow exceeding the patient's minute ventilation (>6-10 L/minute.). If not, the amount of oxygen delivered will be too small to effectively increase the arterial oxygen saturation. Moreover, the risk of carbon dioxide rebreathing dramatically increases if the flow of oxygen to a non-rebreathing mask is lower than the minute ventilation, especially in patients with chronic obstructive pulmonary disease and low tidal volumes. Non-rebreathing masks (with oxygen reservoir bags) must be used cautiously by experienced medical staff and with an appropriately high oxygen flow of 10-15 L/minute. Nevertheless, arterial blood gases must be analyzed regularly for early detection of a rise in partial pressure of carbon dioxide in arterial blood in patients with chronic obstructive pulmonary disease and a hypoxic ventilatory drive. These patients are more safely managed using a nasal cannula with an oxygen flow of 1-2L/minute or a simple face mask with an oxygen flow of 5L/minute.

  8. Metabolism of Citrate and Other Carboxylic Acids in Erythrocytes As a Function of Oxygen Saturation and Refrigerated Storage

    Directory of Open Access Journals (Sweden)

    Travis Nemkov

    2017-10-01

    Full Text Available State-of-the-art proteomics technologies have recently helped to elucidate the unanticipated complexity of red blood cell metabolism. One recent example is citrate metabolism, which is catalyzed by cytosolic isoforms of Krebs cycle enzymes that are present and active in mature erythrocytes and was determined using quantitative metabolic flux analysis. In previous studies, we reported significant increases in glycolytic fluxes in red blood cells exposed to hypoxia in vitro or in vivo, an observation relevant to transfusion medicine owing to the potential benefits associated with hypoxic storage of packed red blood cells. Here, using a combination of steady state and quantitative tracing metabolomics experiments with 13C1,2,3-glucose, 13C6-citrate, 13C515N2-glutamine, and 13C1-aspartate via ultra-high performance liquid chromatography coupled on line with mass spectrometry, we observed that hypoxia in vivo and in vitro promotes consumption of citrate and other carboxylates. These metabolic reactions are theoretically explained by the activity of cytosolic malate dehydrogenase 1 and isocitrate dehydrogenase 1 (abundantly represented in the red blood cell proteome, though moonlighting functions of additional enzymes cannot be ruled out. These observations enhance understanding of red blood cell metabolic responses to hypoxia, which could be relevant to understand systemic physiological and pathological responses to high altitude, ischemia, hemorrhage, sepsis, pulmonary hypertension, or hemoglobinopathies. Results from this study will also inform the design and testing of novel additive solutions that optimize red blood cell storage under oxygen-controlled conditions.

  9. Cerebral time domain-NIRS: reproducibility analysis, optical properties, hemoglobin species and tissue oxygen saturation in a cohort of adult subjects.

    Science.gov (United States)

    Giacalone, Giacomo; Zanoletti, Marta; Contini, Davide; Re, Rebecca; Spinelli, Lorenzo; Roveri, Luisa; Torricelli, Alessandro

    2017-11-01

    The reproducibility of cerebral time-domain near-infrared spectroscopy (TD-NIRS) has not been investigated so far. Besides, reference intervals of cerebral optical properties, of absolute concentrations of deoxygenated-hemoglobin (HbR), oxygenated-hemoglobin (HbO), total hemoglobin (HbT) and tissue oxygen saturation (StO 2 ) and their variability have not been reported. We have addressed these issues on a sample of 88 adult healthy subjects. TD-NIRS measurements at 690, 785, 830 nm were fitted with the diffusion model for semi-infinite homogenous media. Reproducibility, performed on 3 measurements at 5 minutes intervals, ranges from 1.8 to 6.9% for each of the hemoglobin species. The mean ± SD global values of HbR, HbO, HbT, StO 2 are respectively 24 ± 7 μM, 33.3 ± 9.5 μM, 57.4 ± 15.8 μM, 58 ± 4.2%. StO 2 displays the narrowest range of variability across brain regions.

  10. The role of central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference as a goal and prognosis of sepsis treatment.

    Science.gov (United States)

    Wittayachamnankul, Borwon; Chentanakij, Boriboon; Sruamsiri, Kamphee; Chattipakorn, Nipon

    2016-12-01

    The current practice in treatment of severe sepsis and septic shock is to ensure adequate oxygenation and perfusion in patients, along with prompt administration of antibiotics, within 6 hours from diagnosis, which is considered the "golden hour" for the patients. One of the goals of treatment is to restore normal tissue perfusion. With this goal in mind, some parameters have been used to determine the success of treatment and mortality rate; however, none has been proven to be the best predictor of mortality rate in sepsis patients. Despite growing evidence regarding the prognostic indicators for mortality in sepsis patients, inconsistent reports exist. This review comprehensively summarizes the reports regarding the frequently used parameters in sepsis including central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference, as prognostic indicators for clinical outcomes in sepsis patients. Moreover, consistent findings and inconsistent reports for their pathophysiology and the potential mechanisms for their use as well as their limitations in sepsis patients are presented and discussed. Finally, a schematic strategy for potential management and benefits in sepsis patients is proposed based upon these current available data. There is currently no ideal biomarker that can indicate prognosis, predict progression of the disease, and guide treatment in sepsis. Further studies are needed to be carried out to identify the ideal biomarker that has all the desired properties. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Tackling the Saturation of Oxygen: The Use of Phosphorus and Sulfur as Proxies within the Neutral Interstellar Medium of Star-forming Galaxies

    Science.gov (United States)

    James, B.; Aloisi, A.

    2018-02-01

    The abundance of oxygen in galaxies is widely used in furthering our understanding of galaxy formation and evolution. Unfortunately, direct measurements of O/H in the neutral gas are extremely difficult to obtain, as the only O I line available within the Hubble Space Telescope (HST) UV wavelength range (1150–3200 Å) is often saturated. As such, proxies for oxygen are needed to indirectly derive O/H via the assumption that solar ratios based on local Milky Way sight lines hold in different environments. In this paper we assess the validity of using two such proxies, P II and S II, within more typical star-forming environments. Using HST-Cosmic Origins Spectrograph (COS) far-UV (FUV) spectra of a sample of nearby star-forming galaxies (SFGs) and the oxygen abundances in their ionized gas, we demonstrate that both P and S are mildly depleted with respect to O and follow a trend, log(P II/S II) = -1.73 +/- 0.18, in excellent agreement with the solar ratio of {log}{({{P}}/{{S}})}ȯ =-1.71 +/- 0.04 over the large range of metallicities (0.03–3.2 Z ⊙) and H I column densities ({log}[N(H I)/cm‑2] =18.44–21.28) spanned by the sample. From literature data we show evidence that both elements individually trace oxygen according to their respective solar ratios across a wide range of environments. Our findings demonst-rate that the solar ratios of {log}{({{P}}/{{O}})}ȯ =-3.28+/- 0.06 and {log}{({{S}}/{{O}})}ȯ =-1.57+/- 0.06 can both be used to derive reliable O/H abundances in the neutral gas of local and high-redshift SFGs. The difference between O/H in the ionized- and neutral gas phases is studied with respect to metallicity and H I content. The observed trends are consistent with galactic outflows and/or star formation inefficiency affecting the most metal-poor galaxies, with the possibility of primordial gas accretion at all metallicities.

  12. Interplay of crystal fractionation, sulfide saturation and oxygen fugacity on the iron isotope composition of arc lavas: An example from the Marianas

    Science.gov (United States)

    Williams, H. M.; Prytulak, J.; Woodhead, J. D.; Kelley, K. A.; Brounce, M.; Plank, T.

    2018-04-01

    Subduction zone systems are central to a multitude of processes from the evolution of the continental crust to the concentration of metals into economically viable deposits. The interplay between oxygen fugacity, sulfur saturation, fluid exsolution and fractionating mineral assemblages that gives rise to typical arc magma chemical signatures is, however, still poorly understood and novel geochemical approaches are required to make further progress. Here we examine a well-characterized suite of arc lavas from the Marianas (W. Pacific) for their stable Fe isotope composition. In agreement with previous work and mass balance considerations, contributions from sediments and/or fluids are shown to have negligible effect on Fe isotopes. Instead, we focus on disentangling processes occurring during basalt through dacite differentiation using a sample suite from the island of Anatahan. Anatahan whole rock Fe isotope compositions (δ57Fe) range from -0.05 ± 0.05 to 0.17 ± 0.03 (2 S.D.)‰. A fractionation model is constructed, where three distinct stages of differentiation are required to satisfy the combined major and trace element and isotopic observations. In particular, the sequestration of isotopically heavy Fe into magnetite and isotopically light Fe into sulfide melts yields important constraints. The data require that lavas are first undersaturated with respect to crystalline or molten sulfide, followed by the crystallisation of magnetite, which then triggers late sulfide saturation. The model demonstrates that the final stage of removal of liquid or crystalline sulfide can effectively sequester Cu (and presumably other chalcophiles) and that late stage exsolution of magmatic fluids or brines may not be required to do this, although these processes are not mutually exclusive. Finally, the new Fe isotope data are combined with previous Tl-Mo-V stable isotope determinations on the same samples. Importantly, the multi-valent transition metal stable isotope systems of

  13. Pre-clinical evaluation of OxyChip for long-term EPR oximetry.

    Science.gov (United States)

    Hou, Huagang; Khan, Nadeem; Gohain, Sangeeta; Kuppusamy, M Lakshmi; Kuppusamy, Periannan

    2018-03-16

    Tissue oxygenation is a critical parameter in various pathophysiological situations including cardiovascular disease and cancer. Hypoxia can significantly influence the prognosis of solid malignancies and the efficacy of their treatment by radiation or chemotherapy. Electron paramagnetic resonance (EPR) oximetry is a reliable method for repeatedly assessing and monitoring oxygen levels in tissues. Lithium octa-n-butoxynaphthalocyanine (LiNc-BuO) has been developed as a probe for biological EPR oximetry, especially for clinical use. However, clinical applicability of LiNc-BuO crystals is hampered by potential limitations associated with biocompatibility, biodegradation, or migration of individual bare crystals in tissue. To overcome these limitations, we have embedded LiNc-BuO crystals in polydimethylsiloxane (PDMS), an oxygen-permeable biocompatible polymer and developed an implantable/retrievable form of chip, called OxyChip. The chip was optimized for maximum spin density (40% w/w of LiNc-BuO in PDMS) and fabricated in a form suitable for implantation using an 18-G syringe needle. In vitro evaluation of the OxyChip showed that it is robust and highly oxygen sensitive. The dependence of its EPR linewidth to oxygen was linear and highly reproducible. In vivo efficacy of the OxyChip was evaluated by implanting it in rat femoris muscle and following its response to tissue oxygenation for up to 12 months. The results revealed preservation of the integrity (size and shape) and calibration (oxygen sensitivity) of the OxyChip throughout the implantation period. Further, no inflammatory or adverse reaction around the implantation area was observed thereby establishing its biocompatibility and safety. Overall, the results demonstrated that the newly-fabricated high-sensitive OxyChip is capable of providing long-term measurements of oxygen concentration in a reliable and repeated manner under clinical conditions.

  14. Cerebral and Renal Oxygen Saturation Are Not Compromised in the Presence of Retrograde Blood Flow in either the Ascending or Descending Aorta in Term or Near-Term Infants with Left-Sided Obstructive Lesions

    NARCIS (Netherlands)

    van der Laan, Michelle E.; Mebius, Mirthe J.; Roofthooft, Marcus T. R.; Bos, Arend F.; Berger, Rolf M. F.; Kooi, Elisabeth M. W.

    2017-01-01

    Background: In infants with left-sided obstructive lesions (LSOL), the presence of retrograde blood flow in either the ascending or descending aorta may lead to diminished cerebral and renal blood flow, respectively. Objectives: Our aim was to compare cerebral and renal tissue oxygen saturation

  15. Society of cardiovascular anesthesiologists: the effect of blood pressure regulation during aortic coarctation repair on brain, kidney, and muscle oxygen saturation measured by near-infrared spectroscopy: a randomized, clinical trial

    NARCIS (Netherlands)

    Moerman, Annelies; Bové, Thierry; François, Katrien; Jacobs, Stefan; Deblaere, Isabel; Wouters, Patrick; de Hert, Stefan

    2013-01-01

    In this study, we compared the effects of 3 frequently used arterial blood pressure-regulating agents on brain (rScO2), renal (SrO2), and muscle (SmO2) oxygen saturation, during aortic coarctation repair in children. Based on the reported adverse effect of sodium nitroprusside (SNP) on left-sided

  16. Toward translating near-infrared spectroscopy oxygen saturation data for the non-invasive prediction of spatial and temporal hemodynamics during exercise

    Science.gov (United States)

    Ellwein, Laura; Samyn, Margaret M.; Danduran, Michael; Schindler-Ivens, Sheila; Liebham, Stacy; LaDisa, John F.

    2016-01-01

    Image-based computational fluid dynamics (CFD) studies conducted at rest have shown that atherosclerotic plaque in the thoracic aorta (TA) correlates with adverse wall shear stress (WSS), but there is a paucity of such data under elevated flow conditions. We developed a pedaling exercise protocol to obtain phase contrast magnetic resonance imaging (PC-MRI) blood flow measurements in the TA and brachiocephalic arteries during three-tiered supine pedaling at 130%, 150%, and 170% of resting heart rate (HR), and relate these measurements to noninvasive tissue oxygen saturation (StO2) acquired by near-infrared spectroscopy (NIRS) while conducting the same protocol. Local quantification of WSS indices by CFD revealed low time-averaged WSS on the outer curvature of the ascending aorta and the inner curvature of the descending aorta (dAo) that progressively increased with exercise, but that remained low on the anterior surface of brachiocephalic arteries. High oscillatory WSS observed on the inner curvature of the aorta persisted during exercise as well. Results suggest locally continuous exposure to potentially deleterious indices of WSS despite benefits of exercise. Linear relationships between flow distributions and tissue oxygen extraction calculated from StO2 were found between the left common carotid versus cerebral tissue (r2=0.96) and the dAo versus leg tissue (r2=0.87). A resulting six-step procedure is presented to use NIRS data as a surrogate for exercise PC-MRI when setting boundary conditions for future CFD studies of the TA under simulated exercise conditions. Relationships and ensemble averaged PC-MRI inflow waveforms are provided in an online repository for this purpose. PMID:27376865

  17. Improvement of Infrared Detectors for Tissue Oximetry using Black Silicon Nanostructures

    DEFF Research Database (Denmark)

    Petersen, Søren Dahl; Davidsen, Rasmus Schmidt; Alcala, Lucia R.

    2014-01-01

    We present a nanostructured surface, made of dry etched black silicon, which lowers the reflectance for light incident at all angles. This surface is fabricated on infrared detectors used for tissue oximetry, where the detection of weak diffuse light signals is important. Monte Carlo simulations...... performed on a model of a neonatal head shows that approximately 60% of the injected light will be diffuse reflected. However, the change in diffuse reflected light due to the change in cerebral oxygenation is very low and the light will be completely isotropic scattered. The reflectance of the black...... in quantum efficiency for both normal incident light and light incident at 38°....

  18. Healthy Dental Pulp Oxygen Saturation Rates in Subjects with Homozygous Sickle Cell Anemia: A Cross-Sectional Study Nested in a Cohort.

    Science.gov (United States)

    Souza, Soraia de Fátima Carvalho; Thomaz, Erika Bárbara Abreu Fonseca; Costa, Cyrene Piazera Silva

    2017-12-01

    To compare the percentage of arterial oxygen saturation (SpO 2 ) in healthy teeth with confirmed pulp vitality between individuals with sickle cell anemia (HbSS) and normal hemoglobin A (HbAA). This is a cross-sectional study nested within a cohort. Samples (n = 2543) comprised teeth with intact crowns and pulp vitality confirmed by thermal sensitivity tests and no history of caries, periodontal disease, or dental trauma. A total of 728 teeth of 113 individuals with HbSS and 1815 teeth of 246 individuals with HbAA were evaluated. Data analysis was performed using the χ 2 and Mann-Whitney tests and Spearman correlation analysis (α = 0.05). The study groups were comparable in terms of age, race, and sex (P > .05). Subjects with HbSS exhibited lower median SpO 2 levels in the body and upper teeth, excluding canines, than subjects with HbAA (P  .05). Compared with individuals with HbAA, those with HbSS exhibited lower SpO 2 in maxillary teeth with confirmed pulp vitality, except in the canines. There was no correlation between SpO 2 levels of the body and dental pulp in individuals with HbSS or HbAA. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Combining central venous-to-arterial partial pressure of carbon dioxide difference and central venous oxygen saturation to guide resuscitation in septic shock.

    Science.gov (United States)

    Du, Wei; Liu, Da-Wei; Wang, Xiao-Ting; Long, Yun; Chai, Wen-Zhao; Zhou, Xiang; Rui, Xi

    2013-12-01

    Central venous oxygen saturation (Scvo2) is a useful therapeutic target when treating septic shock. We hypothesized that combining Scvo2 and central venous-to-arterial partial pressure of carbon dioxide difference (△Pco2) may provide additional information about survival. We performed a retrospective analysis of 172 patients treated for septic shock. All patients were treated using goal-directed therapy to achieve Scvo2 ≥ 70%. After 6 hours of treatment, we divided patients into 4 groups based on Scvo2 (<70% or ≥ 70%) and △Pco2 (<6 mm Hg or ≥ 6 mm Hg). Overall, 28-day mortality was 35.5%. For patients in whom the Scvo2 target was not achieved at 6 hours, mortality was 50.0%, compared with 29.5% in those in whom Scvo2 exceeded 70% (P = .009). In patients with Scvo2 ≥ 70%, mortality was lower if △Pco2 was <6 mm Hg than if △Pco2 was ≥ 6 mm Hg (56.1% vs 16.1%, respectively; P < .001) and 6-hour lactate clearance was superior (0.01 ± 0.61 vs 0.21 ± 0.31, respectively; P = .016). The combination of Scvo2 and △Pco2 appears to predict outcome in critically ill patients resuscitated from septic shock better than Scvo2 alone. Patients who meet both targets appear to clear lactate more efficiently. © 2013.

  20. Inaccurate pulse CO-oximetry of carboxyhemoglobin due to digital clubbing: case report.

    Science.gov (United States)

    Harlan, Nicole; Weaver, Lindell K; Deru, Kayla

    2016-01-01

    Newer pulse CO-oximeters provide a non-invasive and quick means of measuring oxyhemoglobin, carboxyhemoglobin and methemoglobin. Clubbing has been reported to cause inaccuracy in pulse oximeters. We present a case of inaccurate carboxy-hemoglobin measurement by pulse CO-oximetry due to digital clubbing. An 18-year-old man with a history of cystic fibrosis presented after a suicide attempt by inhalation of exhaust. At the initial emergency department evaluation, his blood carboxyhemoglobin was 33%. He was intubated, placed on 100% oxygen and transferred to our facility. Upon arrival, we placed three different pulse CO-oximeters on different fingers and toes. Carboxyhemoglobin levels measured by these meters ranged from 9%-11%. A venous blood gas drawn on arrival showed a carboxyhemoglobin level of 2.3% after four hours on 100% oxygen by endotracheal tube. Thirty minutes later, we checked arterial blood gas, which revealed a COHb level of 0.9%. Again, non-invasive carboxyhemoglobin measurements read 10%. The patient was treated with hyperbaric oxygen for carbon monoxide poisoning. This case suggests that non-invasive measurements of carboxyhemoglobin should be correlated with the clinic history and with an arterial or venous blood gas oximetry analysis.

  1. Cutaneous Mitochondrial PO2, but Not Tissue Oxygen Saturation, Is an Early Indicator of the Physiologic Limit of Hemodilution in the Pig.

    Science.gov (United States)

    Römers, Luuk H L; Bakker, Charlotte; Dollée, Nathalie; Hoeks, Sanne E; Lima, Alexandre; Raat, Nicolaas J H; Johannes, Tanja; Stolker, Robert J; Mik, Egbert G

    2016-07-01

    Hemodilution is a consequence of fluid replacement during blood loss and is limited by the individual ability to compensate for decreasing hemoglobin level. We tested the ability of a novel noninvasive method for measuring cutaneous mitochondrial PO2 (mitoPO2) to detect this threshold early. Anesthetized and ventilated pigs were hemodynamically monitored and randomized into a hemodilution (n = 12) or a time control (TC) group (n = 14). MitoPO2 measurements were done by oxygen-dependent delayed fluorescence of protoporphyrin IX after preparation of the skin with 20% 5-aminolevulinic acid cream. Tissue oxygen saturation (StO2) was measured with near infrared spectroscopy on the thoracic wall. After baseline measurements, progressive normovolemic hemodilution was performed in the hemodilution group in equal steps (500 ml blood replaced by 500 ml Voluven; Fresenius Kabi AG, Germany). Consecutive measurements were performed after 20-min stabilization periods and repeated 8 times or until the animal died. The TC animals remained stable with regard to hemodynamics and mitoPO2. In the hemodilution group, mitoPO2 became hemoglobin-dependent after reaching a threshold of 2.6 ± 0.2 g/dl. During hemodilution, hemoglobin and mitoPO2 decreased (7.9 ± 0.2 to 2.1 ± 0.2 g/dl; 23.6 ± 2 to 9.9 ± 0.8 mmHg), but StO2 did not. Notably, mitoPO2 dropped quite abruptly (about 39%) at the individual threshold. We observed that this decrease in mitoPO2 occurred at least one hemodilution step before changes in other conventional parameters. Cutaneous mitoPO2 decreased typically one hemodilution step before occurrence of significant alterations in systemic oxygen consumption and lactate levels. This makes mitoPO2 a potential early indicator of the physiologic limit of hemodilution and possibly a physiologic trigger for blood transfusion.

  2. Multisite EPR oximetry from multiple quadrature harmonics.

    Science.gov (United States)

    Ahmad, R; Som, S; Johnson, D H; Zweier, J L; Kuppusamy, P; Potter, L C

    2012-01-01

    Multisite continuous wave (CW) electron paramagnetic resonance (EPR) oximetry using multiple quadrature field modulation harmonics is presented. First, a recently developed digital receiver is used to extract multiple harmonics of field modulated projection data. Second, a forward model is presented that relates the projection data to unknown parameters, including linewidth at each site. Third, a maximum likelihood estimator of unknown parameters is reported using an iterative algorithm capable of jointly processing multiple quadrature harmonics. The data modeling and processing are applicable for parametric lineshapes under nonsaturating conditions. Joint processing of multiple harmonics leads to 2-3-fold acceleration of EPR data acquisition. For demonstration in two spatial dimensions, both simulations and phantom studies on an L-band system are reported. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Feasibility of Pulse Oximetry Pre-discharge Screening ...

    African Journals Online (AJOL)

    Feasibility of Pulse Oximetry Pre-discharge Screening Implementation for detecting Critical Congenital heart Lesions in newborns in a secondary-level maternity hospital in the Western Cape, South Africa: The 'POPSICLe' study.

  4. Nano-emulsions of fluorinated trityl radicals as sensors for EPR oximetry

    Science.gov (United States)

    Charlier, N.; Driesschaert, B.; Wauthoz, N.; Beghein, N.; Préat, V.; Amighi, K.; Marchand-Brynaert, J.; Gallez, B.

    2009-04-01

    This article reports the development and evaluation of two nano-emulsions (F45T-03/HFB and F15T-03/PFOB) containing fluorinated trityl radicals dissolved in perfluorocarbons. Preparation with a high-pressure homogenizer conferred sub-micronic size to both nano-emulsions. In vitro and in vivo EPR spectroscopy showed that the nano-emulsions had much greater oxygen sensitivity than the hydrophilic trityl, CT-03. In vivo experiments in rodents confirmed the ability of the nano-emulsions to follow the changes in oxygen concentration after induced ischemia. Histological evaluation of the tissue injected with the nano-emulsions revealed some acute toxicity for the F45T-03/HFB nano-emulsion but none for the F15T-03/PFOB nano-emulsion. These new formulations should be considered for further EPR oximetry experiments in pathophysiological situations where subtle changes in tissue oxygenation are expected.

  5. Regional oxygen saturation index (rSO2) in brachioradialis and deltoid muscle. Correlation and prognosis in patients with respiratory sepsis.

    Science.gov (United States)

    Rodríguez, A; Claverias, L; Marín, J; Magret, M; Rosich, S; Bodí, M; Trefler, S; Pascual, S; Gea, J

    2015-03-01

    To compare oxygen saturation index (rSO2) obtained simultaneously in two different brachial muscles. Prospective and observational study. Intensive care unit. Critically ill patients with community-acquired pneumonia. Two probes of NIRS device (INVOS 5100) were simultaneously placed on the brachioradialis (BR) and deltoid (D) muscles. rSO2 measurements were recorded at baseline (ICU admission) and at 24h. Demographic and clinical variables were registered. Pearson's correlation coefficient was used to assess the association between continuous variables. The consistency of the correlation was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman plot. The predictive value of the rSO2 for mortality was calculated by ROC curve. Nineteen patients were included with an ICU mortality of 21.1%. The rSO2 values at baseline and at 24h were significantly higher in D than in BR muscle. Values obtained simultaneously in both limbs showed a strong correlation and adequate consistency: BR (r=0.95; p0.001) but a wide limit of agreement. Non-survivors had rSO2 values significantly lower than survivors at all times of the study. No patient with rSO2 >60% in BR died, and only 17.6% died with an rSO2 value >60% in D. Both muscles showed consistent discriminatory power for mortality. Both BR and D muscles were appropriate for measuring rSO2. Copyright © 2013 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  6. A confocal scanning laser ophthalmoscope for retinal vessel oximetry

    Science.gov (United States)

    Lompado, Arthur

    Measurement of a person's blood oxygen saturation has long been recognized as a useful metric for the characterizing ailments ranging from chronic respiratory disorders to acute, potentially life threatening, traumas. The ubiquity of oxygen saturation monitors in the medical field, including portable pulse oximeters and laboratory based CO-oximeters, is a testament to the importance of this technique. The work presented here documents the design, fabrication and development of a unique type of oxygen saturation monitor, a confocal scanning retinal vessel oximeter, with the potential to expand the usefulness of the present devices. A large part of the knowledge base required to construct the instrument comes from the consideration of light scattering by red blood cells in a blood vessel. Therefore, a substantial portion of this work is devoted to the process of light scattering by whole human blood and its effects on the development of a more accurate oximeter. This light scattering effect has been both measured and modeled stochastically to determine its contribution to the measured oximeter signal. It is shown that, although well accepted in the published literature, the model only correlates marginally to the measurements due to inherent limitations imposed by the model assumptions. Nonetheless, enough material has been learned about the scattering to allow development of a mathematical model for the interaction of light with blood in a vessel, and this knowledge has been applied to the data reduction of the present oximeter. This data reduction technique has been tested in a controlled experiment employing a model eye with a blood filled mock retinal vessel. It will be shown that the presently developed technique exhibited strong correlation between the known blood oxygen saturation and that calculated by the new system.

  7. Assessment of anastomotic reliability with pulse oximetry in graded intestinal ischemia: an experimental study in dogs.

    Science.gov (United States)

    Türkyilmaz, Z; Sönmez, K; Başaklar, A C; Demiroğullari, B; Numanoğlu, V; Ekingen, G; Dursun, A; Altin, M A; Kale, N

    1997-12-01

    groups with average preanastomotic pulse measurements of 96% and 85%, respectively is not statistically significant enables us to suggest that a saturation of at least 85% is necessary for a reliable anastomosis. These results suggest clearly that anastomotic reliability can be predicted objectively with pulse oximetry.

  8. Carbogen Enhanced Femto Oximetry Breast Cancer Diagnosis Method with High Specificity

    Science.gov (United States)

    Maglich, Bogdan C.; Shultis, J. K.; Solomon, C. J.

    2011-03-01

    As large malignant tumors are oxygen deficient (hypoxic), cancer could be diagnosed in vivo and online, by non-invasive measurement of oxygen difference between tumor and adjacent tissue. Computer simulations of noninvasive diagnosis by Femto Oximetry (FO) of hypoxia in 1 cm tumor in 10 cm breast shows that background γ 's from non hypoxic tissue will mask hypoxia. To amplify the hypoxic-to-normal O difference, air breathing will be replaced with carbogen (O2 95 % , CO2 5 %) using vasco-constrictive property whereby carbogen breathing increases O in normal tissue, while not in malignant hypoxic tumors. 90% hypoxia will be detectable by FO with specificity 99%. Our method will be tested on R3230 tumors in Fischer rats at UCI.

  9. Interleaved quantitative BOLD: Combining extravascular R2' - and intravascular R2-measurements for estimation of deoxygenated blood volume and hemoglobin oxygen saturation.

    Science.gov (United States)

    Lee, Hyunyeol; Englund, Erin K; Wehrli, Felix W

    2018-03-23

    Quantitative BOLD (qBOLD), a non-invasive MRI method for assessment of hemodynamic and metabolic properties of the brain in the baseline state, provides spatial maps of deoxygenated blood volume fraction (DBV) and hemoglobin oxygen saturation (HbO 2 ) by means of an analytical model for the temporal evolution of free-induction-decay signals in the extravascular compartment. However, mutual coupling between DBV and HbO 2 in the signal model results in considerable estimation uncertainty precluding achievement of a unique set of solutions. To address this problem, we developed an interleaved qBOLD method (iqBOLD) that combines extravascular R 2 ' and intravascular R 2 mapping techniques so as to obtain prior knowledge for the two unknown parameters. To achieve these goals, asymmetric spin echo and velocity-selective spin-labeling (VSSL) modules were interleaved in a single pulse sequence. Prior to VSSL, arterial blood and CSF signals were suppressed to produce reliable estimates for cerebral venous blood volume fraction (CBV v ) as well as venous blood R 2 (to yield HbO 2 ). Parameter maps derived from the VSSL module were employed to initialize DBV and HbO 2 in the qBOLD processing. Numerical simulations and in vivo experiments at 3 T were performed to evaluate the performance of iqBOLD in comparison to the parent qBOLD method. Data obtained in eight healthy subjects yielded plausible values averaging 60.1 ± 3.3% for HbO 2 and 3.1 ± 0.5 and 2.0 ± 0.4% for DBV in gray and white matter, respectively. Furthermore, the results show that prior estimates of CBV v and HbO 2 from the VSSL component enhance the solution stability in the qBOLD processing, and thus suggest the feasibility of iqBOLD as a promising alternative to the conventional technique for quantifying neurometabolic parameters. Copyright © 2018. Published by Elsevier Inc.

  10. The association between lactate, mean arterial pressure, central venous oxygen saturation and peripheral temperature and mortality in severe sepsis: a retrospective cohort analysis.

    Science.gov (United States)

    Houwink, Aletta P I; Rijkenberg, Saskia; Bosman, Rob J; van der Voort, Peter H J

    2016-03-12

    During resuscitation in severe sepsis and septic shock, several goals are set. However, usually not all goals are equally met. The aim of this study is to determine the relative importance of the different goals, such as mean arterial pressure (MAP), lactate, central venous oxygen saturation (ScvO2) and central to forefoot temperature (delta-T), and how they relate to intensive care unit (ICU) and hospital mortality. In a retrospective cohort study in a 20-bed mixed medical and surgical ICU of a teaching hospital we studied consecutive critically ill patients who were admitted for confirmed infection and severe sepsis or septic shock between 2008 and 2014. All validated MAP, lactate levels, ScvO2 and delta-T for the first 24 hours of ICU treatment were extracted from a clinical database. Logistic regression analyses were performed on validated measurements in the first hour after admission and on mean values over 24 hours. Patients were categorized by MAP (24-hour mean below or above 65 mmHg) and lactate (24-hour mean below or above 2 mmol/l) for Cox regression analysis. From 837 patients, 821 were eligible for analysis. All had MAP and lactate measurements. The delta-T was available in 812 (99%) and ScvO2 was available for 193 out of these patients (23.5%). Admission lactate (p < 0.001) and admission MAP (p < 0.001) were independent predictors of ICU and hospital mortality. The 24-hour mean values for lactate, MAP and delta-T were all independent predictors of ICU mortality. Hospital mortality was independently predicted by the 24-hour mean lactate (odds ratio (OR) 1.34, 95% confidence interval (CI) 1.30-1.40, p = 0.001) mean MAP (OR 0.96, 95% CI 0.95-0.97, p = 0.001) and mean delta-T (OR 1.09, 95% CI 1.06-1.12, p = 0.001). Patients with a 24-hour mean lactate below 2 mmol/l and a 24-hour mean MAP above 65 mmHg had the best survival, followed by patients with a low lactate and a low MAP. Admission MAP and lactate independently predicted ICU and hospital mortality

  11. Simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in humans and other animal models using a single light source

    Science.gov (United States)

    Dent, Paul; Tun, Sai Han; Fillioe, Seth; Deng, Bin; Satalin, Josh; Nieman, Gary; Wilcox, Kailyn; Searles, Quinn; Narsipur, Sri; Peterson, Charles M.; Goodisman, Jerry; Mostrom, James; Steinmann, Richard; Chaiken, J.

    2018-02-01

    We previously reported a new algorithm "PV[O]H" for continuous, noninvasive, in vivo monitoring of hematocrit changes in blood and have since shown its utility for monitoring in humans during 1) hemodialysis, 2) orthostatic perturbations and 3) during blood loss and fluid replacement in a rat model. We now show that the algorithm is sensitive to changes in hemoglobin oxygen saturation. We document the phenomenology of the effect and explain the effect using new results obtained from humans and rat models. The oxygen sensitivity derives from the differential absorption of autofluorescence originating in the static tissues by oxy and deoxy hemoglobin. Using this approach we show how to perform simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in mammals using a single light source. We suspect that monitoring of changes in this suite of vital signs can be provided with improved time response, sensitivity and precision compared to existing methodologies. Initial results also offer a more detailed glimpse into the systemic oxygen transport in the circulatory system of humans.

  12. Oxygen supplementation in anesthetized brown bears (Ursus arctos)-how low can you go?

    Science.gov (United States)

    Fahlman, Åsa; Arnemo, Jon M; Pringle, John; Nyman, Görel

    2014-07-01

    Hypoxemia is anticipated during wildlife anesthesia and thus should be prevented. We evaluated the efficacy of low flow rates of supplemental oxygen for improvement of arterial oxygenation in anesthetized brown bears (Ursus arctos). The study included 32 free-ranging brown bears (yearlings, subadults, and adults; body mass 12-250 kg) that were darted with medetomidine-zolazepam-tiletamine (MZT) from a helicopter in Sweden. During anesthesia, oxygen was administered intranasally from portable oxygen cylinders at different flow rates (0.5-3 L/min). Arterial blood samples were collected before (pre-O2), during, and after oxygen therapy and immediately processed with a portable analyzer. Rectal temperature, respiratory rate, heart rate, and pulse oximetry-derived hemoglobin oxygen saturation were recorded. Intranasal oxygen supplementation at the evaluated flow rates significantly increased the partial pressure of arterial oxygen (PaO2) from pre-O2 values of 9.1 ± 1.3 (6.3-10.9) kPa to 20.4 ± 6.8 (11.1-38.7) kPa during oxygen therapy. When oxygen therapy was discontinued, the PaO2 decreased to values not significantly different from the pre-O2 values. In relation to the body mass of the bears, the following oxygen flow rates are recommended: 0.5 L/min to bears bears 51-100 kg, 2 L/min to bears 101-200 kg, and 3 L/min to bears 201-250 kg. In conclusion, low flow rates of intranasal oxygen were sufficient to improve arterial oxygenation in brown bears anesthetized with MZT. Because hypoxemia quickly recurred when oxygen was discontinued, oxygen supplementation should be provided continuously throughout anesthesia.

  13. Development and initial testing of a pulse oximetry prototype for measuring dental pulp vitality

    Science.gov (United States)

    Cerqueira, M.; Ferreira, M.; Caramelo, F.

    2015-05-01

    The guiding principle of endodontic treatment is to preserve teeth while maintaining its aesthetic and functional roles. To accomplish this goal the assessment of teeth pulp vitality is very important since it will determine the procedures that should be adopted and define the therapy strategy. Currently, the most commonly tests for determining dental pulp state are the thermal and the electrical tests, which are based on nerve response and, because of that, have a relatively high rate of false positives and false negatives cases. In this work we present a simple test to be used in the clinical setting for evaluating noninvasively the existence of blood perfusion in dental pulp. This test is based on pulse oximetry principle that was devised to indirectly measure the amount of oxygen in blood. Although pulse oximetry has already demonstrated its usefulness in clinical environment its usage for the determination of dental pulp vitality has been frustrated by several factors, notably the absence of a suitable sensor to the complex shape of the various coronary teeth. We developed a suitable sensor and present the first trials with promising results, regarding the ability for distinguish teeth with and without blood perfusion.

  14. Simulation based investigation of source-detector configurations for non-invasive fetal pulse oximetry

    Directory of Open Access Journals (Sweden)

    Böttrich Marcel

    2015-09-01

    Full Text Available Transabdominal fetal pulse oximetry is a method to monitor the oxygen supply of the unborn child non-invasively. Due to the measurement setup, the received signal of the detector is composed of photons coding purely maternal and photons coding mixed fetal-maternal information. To analyze the wellbeing of the fetus, the fetal signal is extracted from the mixed component. In this paper we assess source-detector configurations, such that the mixed fetal-maternal components of the acquired signals are maximized. Monte-Carlo method is used to simulate light propagation and photon distribution in tissue. We use a plane layer and a spherical layer geometry to model the abdomen of a pregnant woman. From the simulations we extracted the fluence at the detector side for several source-detector distances and analyzed the ratio of the mixed fluence component to total fluence. Our simulations showed that the power of the mixed component depends on the source-detector distance as expected. Further we were able to visualize hot spot areas in the spherical layer model where the mixed fluence ratio reaches the highest level. The results are of high importance for sensor design considering signal composition and quality for non-invasive fetal pulse oximetry.

  15. Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy La capnografía es superior a la pulsioximetría en la detección de depresión respiratoria durante las colonoscopias

    Directory of Open Access Journals (Sweden)

    G. Cacho

    2010-02-01

    Full Text Available Background: pulse oximetry is a widely accepted procedure for ventilatory monitoring during gastrointestinal endoscopy, but this method provides an indirect measurement of the respiratory function. In addition, detection of abnormal ventilatory activity can be delayed, especially if supplemental oxygen is provided. Capnography offers continuous real-time measurement of expiratory carbon dioxide. Objective: we aimed at prospectively examining the advantages of capnography over the standard pulse oximetry monitoring during sedated colonoscopies. Patients and methods:fifty patients undergoing colonoscopy were simultaneously monitored with pulse oximetry and capnography by using two different devices in each patient. Several sedation regimens were administered. Episodes of apnea or hypoventilation detected by capnography were compared with the occurrence of hypoxemia. Results: twenty-nine episodes of disordered respiration occurred in 16 patients (mean duration 54.4 seconds. Only 38% of apnea or hypoventilation episodes were detected by pulse oximetry. A mean delay of 38.6 seconds was observed in the events detected by pulse oximetry (two episodes of disturbed ventilation were simultaneously detected by capnography and pulse oximetry. Conclusions: apnea or hypoventilation commonly occurs during colonoscopy with sedation. Capnography is more reliable than pulse oximetry in early detection of respiratory depression in this setting.

  16. Harnessing color vision for visual oximetry in central cyanosis.

    Science.gov (United States)

    Changizi, Mark; Rio, Kevin

    2010-01-01

    Central cyanosis refers to a bluish discoloration of the skin, lips, tongue, nails, and mucous membranes, and is due to poor arterial oxygenation. Although skin color is one of its characteristic properties, it has long been realized that by the time skin color signs become visible, oxygen saturation is dangerously low. Here we investigate the visibility of cyanosis in light of recent discoveries on what color vision evolved for in primates. We elucidate why low arterial oxygenation is visible at all, why it is perceived as blue, and why it can be so difficult to perceive. With a better understanding of the relationship between color vision and blood physiology, we suggest two simple techniques for greatly enhancing the clinician's ability to detect cyanosis and other clinical color changes. The first is called "skin-tone adaptation", wherein sheets, gowns, walls and other materials near a patient have a color close to that of the patient's skin, thereby optimizing a color-normal viewer's ability to sense skin color modulations. The second technique is called "biosensor color tabs", wherein adhesive tabs with a color matching the patient's skin tone are placed in several spots on the skin, and subsequent skin color changes have the effect of making the initially-invisible tabs change color, their hue and saturation indicating the direction and magnitude of the skin color shift.

  17. First-in-human pilot study of a spatial frequency domain oxygenation imaging system

    Science.gov (United States)

    Gioux, Sylvain; Mazhar, Amaan; Lee, Bernard T.; Lin, Samuel J.; Tobias, Adam M.; Cuccia, David J.; Stockdale, Alan; Oketokoun, Rafiou; Ashitate, Yoshitomo; Kelly, Edward; Weinmann, Maxwell; Durr, Nicholas J.; Moffitt, Lorissa A.; Durkin, Anthony J.; Tromberg, Bruce J.; Frangioni, John V.

    2011-08-01

    Oxygenation measurements are widely used in patient care. However, most clinically available instruments currently consist of contact probes that only provide global monitoring of the patient (e.g., pulse oximetry probes) or local monitoring of small areas (e.g., spectroscopy-based probes). Visualization of oxygenation over large areas of tissue, without a priori knowledge of the location of defects, has the potential to improve patient management in many surgical and critical care applications. In this study, we present a clinically compatible multispectral spatial frequency domain imaging (SFDI) system optimized for surgical oxygenation imaging. This system was used to image tissue oxygenation over a large area (16×12 cm) and was validated during preclinical studies by comparing results obtained with an FDA-approved clinical oxygenation probe. Skin flap, bowel, and liver vascular occlusion experiments were performed on Yorkshire pigs and demonstrated that over the course of the experiment, relative changes in oxygen saturation measured using SFDI had an accuracy within 10% of those made using the FDA-approved device. Finally, the new SFDI system was translated to the clinic in a first-in-human pilot study that imaged skin flap oxygenation during reconstructive breast surgery. Overall, this study lays the foundation for clinical translation of endogenous contrast imaging using SFDI.

  18. A Comparative Evaluation of EPR and OxyLite Oximetry Using a Random Sampling of pO2 in a Murine Tumor

    Science.gov (United States)

    Vikram, Deepti S.; Bratasz, Anna; Ahmad, Rizwan; Kuppusamy, Periannan

    2015-01-01

    Methods currently available for the measurement of oxygen concentrations (oximetry) in viable tissues differ widely from each other in their methodological basis and applicability. The goal of this study was to compare two novel methods, particulate-based electron paramagnetic resonance (EPR) and OxyLite oximetry, in an experimental tumor model. EPR oximetry uses implantable paramagnetic particulates, whereas OxyLite uses fluorescent probes affixed on a fiber-optic cable. C3H mice were transplanted with radiation-induced fibrosarcoma (RIF-1) tumors in their hind limbs. Lithium phthalocyanine (LiPc) microcrystals were used as EPR probes. The pO2 measurements were taken from random locations at a depth of ~3 mm within the tumor either immediately or 48 h after implantation of LiPc. Both methods revealed significant hypoxia in the tumor. However, there were striking differences between the EPR and OxyLite readings. The differences were attributed to the volume of tissue under examination and the effect of needle invasion at the site of measurement. This study recognizes the unique benefits of EPR oximetry in terms of robustness, repeatability and minimal invasiveness. PMID:17705635

  19. Non-invasive tissue oximetry following unilateral DIEP-flap reconstruction: A pilot evaluation

    Directory of Open Access Journals (Sweden)

    N.P.A. Vranken

    2017-06-01

    Conclusion: Continuous non-invasive tissue oxygen saturation is suitable for postoperative monitoring of DIEP-flaps, and StO2 pattern may aid in early identification of vascular compromise in DIEP-flaps.

  20. Pulse oximetry : technology to reduce child mortality in developing countries

    NARCIS (Netherlands)

    Duke, T.; Subhi, R.; Peel, D.; Frey, B.

    The causes of hypoxaemia in children include the commonest causes of childhood illness: pneumonia and other acute respiratory infections, and neonatal illness, particularly sepsis, low birthweight, birth asphyxia and aspiration syndromes. The systematic use of pulse oximetry to monitor and treat

  1. Vessel calibre and haemoglobin effects on pulse oximetry

    International Nuclear Information System (INIS)

    McEwen, M P; Reynolds, K J; Bull, G P

    2009-01-01

    Despite its success as a clinical monitoring tool, pulse oximetry may be improved with respect to the need for empirical calibration and the reports of biases in readings associated with peripheral vasoconstriction and haemoglobin concentration. To effect this improvement, this work aims to improve the understanding of the photoplethysmography signal—as used by pulse oximeters—and investigates the effect of vessel calibre and haemoglobin concentration on pulse oximetry. The digital temperature and the transmission of a wide spectrum of light through the fingers of 57 people with known haemoglobin concentrations were measured and simulations of the transmission of that spectrum of light through finger models were performed. Ratios of pulsatile attenuations of light as used in pulse oximetry were dependent upon peripheral temperature and on blood haemoglobin concentration. In addition, both the simulation and in vivo results showed that the pulsatile attenuation of light through fingers was approximately proportional to the absorption coefficients of blood, only when the absorption coefficients were small. These findings were explained in terms of discrete blood vessels acting as barriers to light transmission through tissue. Due to the influence of discrete blood vessels on light transmission, pulse oximeter outputs tend to be dependent upon haemoglobin concentration and on the calibre of pulsing blood vessels—which are affected by vasoconstriction/vasodilation. The effects of discrete blood vessels may account for part of the difference between the Beer–Lambert pulse oximetry model and empirical calibration

  2. Quantitative evaluation of photoplethysmographic artifact reduction for pulse oximetry

    Science.gov (United States)

    Hayes, Matthew J.; Smith, Peter R.

    1999-01-01

    Motion artefact corruption of pulse oximeter output, causing both measurement inaccuracies and false alarm conditions, is a primary restriction in the current clinical practice and future applications of this useful technique. Artefact reduction in photoplethysmography (PPG), and therefore by application in pulse oximetry, is demonstrated using a novel non-linear methodology recently proposed by the authors. The significance of these processed PPG signals for pulse oximetry measurement is discussed, with particular attention to the normalization inherent in the artefact reduction process. Quantitative experimental investigation of the performance of PPG artefact reduction is then utilized to evaluate this technology for application to pulse oximetry. While the successfully demonstrated reduction of severe artefacts may widen the applicability of all PPG technologies and decrease the occurrence of pulse oximeter false alarms, the observed reduction of slight artefacts suggests that many such effects may go unnoticed in clinical practice. The signal processing and output averaging used in most commercial oximeters can incorporate these artefact errors into the output, while masking the true PPG signal corruption. It is therefore suggested that PPG artefact reduction should be incorporated into conventional pulse oximetry measurement, even in the absence of end-user artefact problems.

  3. Six-minute walking distance and decrease in oxygen saturation during the six-minute walk test in pediatric pulmonary arterial hypertension

    NARCIS (Netherlands)

    Douwes, Johannes M.; Hegeman, Anneke K.; van der Krieke-van der Horst, Merel; Roofthooft, Marcus T. R.; Hillege, Hans L.; Berger, Rolf M. F.

    2016-01-01

    Objective: To investigate the prognostic value of the 6-minute walking distance (6-MWD), transcutaneous saturation (tcSO2) and heart rate (HR) obtained during the 6-minute walk test (6-MWT) in pediatric pulmonary arterial hypertension (PAH). Methods: This was an observational study with forty-seven

  4. Absolute measurement of cerebral optical coefficients, hemoglobin concentration and oxygen saturation in old and young adults with near-infrared spectroscopy

    Science.gov (United States)

    We present near-infrared spectroscopy measurement of absolute cerebral hemoglobin concentration and saturation in a large sample of 36 healthy elderly (mean age, 85 ± 6 years) and 19 young adults (mean age, 28 ± 4 years). Non-invasive measurements were obtained on the forehead using a commercially a...

  5. Barley seed radiosensitivity following post-hydration in oxygen-, nitrogen- and nitrous oxide-saturated water, 1; Influence of caffeine and t-butyl alcohol

    Energy Technology Data Exchange (ETDEWEB)

    Singh, S.P.; Kesavan, P.C. (Jawaharlal Nehru Univ., New Delhi (India). School of Life Sciences)

    1990-06-01

    Dry ({approx}3.5 and 4.0 per cent moisture content) barley seeds were exposed to 350 Gy of {sup 60}Co-{gamma}-rays in vacuo and post-hydrated at 4degC for 8 h in O{sub 2}-, N{sub 2}-, or N{sub 2}O-saturated water. The effect of caffeine and t-butyl alcohol (t-BuOH) dissolved in the post-hydration medium on the magnitude of damage developing under these three different gaseous circumstances was studied. The post-irradiation damage and its modification by caffeine and t-BuOH was assessed in terms of 8-day-old seedling injury, peroxidase activity and total peroxides in the 8-day-old seedlings. Post-irradiation O{sub 2}-saturated hydration caused maximal 8-day-old seedling injury, and increased peroxidase activity with concomitant reduction in total peroxides. Both caffeine and t-BuOH afforded significant radioprotection against post-irradiation O{sub 2}-dependent damage. Post-irradiation N{sub 2}O-saturated hydration was even more significantly radioprotective than the N{sub 2}-saturated post-hydration. Under these circumstances, t-BuOH exerted no effect whatsoever on the N{sub 2}- and N{sub 2}O-mediated post-irradiation damage. Caffeine, on the other hand, significantly potentiated these two components of damage. A brief consideration of the physicochemical events which possibly account for the observed effects is presented. (author).

  6. Regional Cerebral Oximetry During Cardiopulmonary Resuscitation: Useful or Useless?

    Science.gov (United States)

    Genbrugge, Cornelia; Dens, Jo; Meex, Ingrid; Boer, Willem; Eertmans, Ward; Sabbe, Marc; Jans, Frank; De Deyne, Cathy

    2016-01-01

    Approximately 375,000 people annually experience sudden cardiac arrest (CA) in Europe. Most patients who survive the initial hours and days after CA die of postanoxic brain damage. Current monitors, such as electrocardiography and end-tidal capnography, provide only indirect information about the condition of the brain during cardiopulmonary resuscitation (CPR). In contrast, cerebral near-infrared spectroscopy provides continuous, noninvasive, real-time information about brain oxygenation without the need for a pulsatile blood flow. It measures transcutaneous cerebral tissue oxygen saturation (rSO2). This information could supplement currently used monitors. Moreover, an evolution in rSO2 monitoring technology has made it easier to assess rSO2 in CA conditions. We give an overview of the literature regarding rSO2 measurements during CPR and the current commercially available devices. We highlight the feasibility of cerebral saturation measurement during CPR, its role as a quality parameter of CPR, predictor of return of spontaneous circulation (ROSC) and neurologic outcome, and its monitoring function during transport. rSO2 is feasible in the setting of CA and has the potential to measure the quality of CPR, predict ROSC and neurologic outcome, and monitor post-CA patients during transport. The literature shows that rSO2 has the potential to serve multiple roles as a neuromonitoring tool during CPR and also to guide neuroprotective therapeutic strategies. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Retinal vascular oximetry during ranibizumab treatment of central retinal vein occlusion

    DEFF Research Database (Denmark)

    Traustason, Sindri; la Cour, Morten; Larsen, Michael

    2014-01-01

    PURPOSE: To investigate the effect of intravitreal injections of the vascular endothelial growth factor inhibitor ranibizumab on retinal oxygenation in patients with central retinal vein occlusion (CRVO). METHODS: Retinal oxygen saturation in patients with CRVO was analysed using the Oxymap Retin...

  8. [Values of mixed venous oxygen saturation and difference of mixed venous-arterial partial pressure of carbon dioxide in monitoring of oxygen metabolism and treatment after open-heart operation].

    Science.gov (United States)

    Pan, Chuanliang; Zhang, Haiying; Liu, Jianping

    2014-10-01

    To explore the clinic values of early goal directed treatment (EGDT) with the target of mixed venous oxygen saturation (SvO₂) and difference of mixed venous-arterial partial pressure of carbon dioxide (Pv-aCO₂) in monitoring of oxygen metabolism and treatment for patients post open-heart operation. A prospective study was conducted. The adult patients admitted to Third People's Hospital of Chengdu from December 2011 to March 2014 with SvO₂2 mmol/L when admitted in intensive care unit (ICU) were selected on whom elective open-heart operation and pulmonary artery catheter examination were done. All patients received EGDT with the target of SvO₂≥0.65 and Pv-aCO₂<6 mmHg (1 mmHg=0.133 kPa) and were divided into three groups by the values of SvO₂and Pv-aCO₂at 6-hour after ICU admission: A group with SvO₂≥0.65 and Pv-aCO₂<6 mmHg, B group with SvO₂≥0.65 and Pv-aCO₂≥6 mmHg, and C group with SvO₂<0.65. Then the changes and prognosis of the patients in different groups were observed. 103 cases were included, 44 in A group, 31 in B group and 28 in C group. The acute physiology and chronic health evaluation II (APACHEII) score in group A were significantly lower than that in group B or C at 6, 24, 48 and 72 hours (T6, T24, T48, T72) of ICU admission (T6: 11.4 ± 5.8 vs. 13.9 ± 5.4, 13.7 ± 6.4; T24: 8.8 ± 3.7 vs. 10.8 ± 4.8, 11.8 ± 5.4; T48: 8.7 ± 4.1 vs. 9.6 ± 4.2, 10.2 ± 5.1; T72: 7.5 ± 3.4 vs. 8.6 ± 2.9, 9.2 ± 4.2, all P<0.05), and the sequential organ failure assessment (SOFA) showed the same tendency (T6: 6.5 ± 4.3 vs. 8.0 ± 3.8, 9.1 ± 4.5; T24: 6.6 ±3.6 vs. 8.6 ± 3.9, 8.5 ± 3.3; T48: 5.2 ± 3.4 vs. 7.0 ± 3.6, 7.6 ± 5.1; T72: 4.6 ± 2.4 vs. 5.8 ± 2.5, 6.8 ± 3.5, all P<0.05). The values of blood lactic acid (mmol/L) in group A and B were significant lower than that in group C at T6, T24, T48 and T72 (T6: 1.60 ± 0.95, 2.20 ± 1.02 vs. 2.55 ± 1.39; T24: 2.26 ± 1.26, 2.70 ± 1.36 vs. 3.34 ± 2.36; T48: 2.01 ± 1.15, 2.17

  9. Oxygen concentrators performance with nitrous oxide at 50:50 volume

    Directory of Open Access Journals (Sweden)

    Jorge Ronaldo Moll

    2014-06-01

    Full Text Available Background and objectives: Few investigations have addressed the safety of oxygen from concentrators for use in anesthesia in association with nitrous oxide. This study evaluated the percent of oxygen from a concentrator in association with nitrous oxide in a semi-closed rebreathing circuit. Methods: Adult patients undergoing low risk surgery were randomly allocated into two groups, receiving a fresh gas flow of oxygen from concentrators (O293 or of oxygen from concentrators and nitrous oxide (O293N2O. The fraction of inspired oxygen and the percentage of oxygen from fresh gas flow were measured every 10 min. The ratio of FiO2/oxygen concentration delivered was compared at various time intervals and between the groups. Results: Thirty patients were studied in each group. There was no difference in oxygen from concentrators over time for both groups, but there was a significant improvement in the FiO2 (p < 0.001 for O293 group while a significant decline (p < 0.001 for O293N2O. The FiO2/oxygen ratio varied in both groups, reaching a plateau in the O293 group. Pulse oximetry did not fall below 98.5% in either group. Conclusion: The FiO2 in the mixture of O293 and nitrous oxide fell during the observation period although oxygen saturation was higher than 98.5% throughout the study. Concentrators can be considered a stable source of oxygen for use during short anesthetic procedures, either pure or in association with nitrous oxide at 50:50 volume.

  10. Synergistic combination of hyperoxygenation and radiotherapy by repeated assessments of tumor pO2 with EPR oximetry

    International Nuclear Information System (INIS)

    Hou, H.; Dong, R.; Lariviere, J.P.; Mupparaju, S.P.; Swartz, H.M.; Khan, N.

    2011-01-01

    The effect of hyperoxygenation with carbogen (95% O 2 +5% CO 2 ) inhalation on radiation-induced fibrosarcoma (RIF-1) tumor pO 2 and its consequence on growth inhibition with fractionated radiotherapy is reported. The temporal changes in the tumor pO 2 were assessed by in vivo Electron Paramagnetic Resonance (EPR) oximetry in mice breathing 30% O 2 or carbogen and the tumors were irradiated with 4 Gy/day for 5 consecutive days; a protocol that emulates the clinical application of carbogen. The RIF-1 tumors were hypoxic with a tissue pO 2 of 5-9 mmHg. Carbogen (CB) breathing significantly increased tumor pO 2 , with a maximum increase at 22.9-31.2 min on days 1-5, however, the magnitude of increase in pO 2 declined on day 5. Radiotherapy during carbogen inhalation (CB/RT) resulted in a significant tumor growth inhibition from day 3 to day 6 as compared to 30%O 2 /RT and carbogen (CB/Sham RT) groups. The results provide unambiguous quantitative information on the effect of carbogen inhalation on tumor pO 2 over the course of 5 days. Tumor growth inhibition in the CB/RT group confirms that the tumor oxygenation with carbogen was radiobiologically significant. Repeated tumor pO 2 measurements by EPR oximetry can provide temporal information that could be used to improve therapeutic outcomes by scheduling doses at times of improved tumor oxygenation. (author)

  11. Synergistic combination of hyperoxygenation and radiotherapy by repeated assessments of tumor pO2 with EPR oximetry

    Science.gov (United States)

    HOU, Huagang; DONG, Ruhong; LARIVIERE, Jean P.; MUPPARAJU, Sriram P.; SWARTZ, Harold M.; KHAN, Nadeem

    2013-01-01

    The effect of hyperoxygenation with carbogen (95% O2 + 5% CO2) inhalation on RIF-1 tumor pO2 and its consequence on growth inhibition with fractionated radiotherapy is reported. The temporal changes in the tumor pO2 were assessed by in vivo Electron Paramagnetic Resonance (EPR) oximetry in mice breathing 30% O2 or carbogen and the tumors were irradiated with 4 Gy/day for 5 consecutive days; a protocol that emulates the clinical application of carbogen. The RIF-1 tumors were hypoxic with a tissue pO2 of 5 – 9 mm Hg. Carbogen (CB) breathing significantly increased tumor pO2, with a maximum increase at 22.9 – 31.2 min on days 1 – 5, however, the magnitude of increase in pO2 declined on day 5. Radiotherapy during carbogen inhalation (CB/RT) resulted in a significant tumor growth inhibition from day 3 to day 6 as compared to 30%O2/RT and carbogen (CB/Sham RT) groups. The results provide unambiguous quantitative information on the effect of carbogen inhalation on tumor pO2 over the course of 5 days. Tumor growth inhibition in the CB/RT group confirms that the tumor oxygenation with carbogen was radiobiologically significant. Repeated tumor pO2 measurements by EPR oximetry can provide temporal information that could be used to improve therapeutic outcomes by scheduling doses at times of improved tumor oxygenation. PMID:21799293

  12. Regional tumor oximetry: 19F NMR spectroscopy of hexafluorobenzene

    International Nuclear Information System (INIS)

    Hunjan, Sandeep; Mason, Ralph P.; Constantinescu, Anca; Peschke, Peter; Hahn, Eric W.; Antich, Peter P.

    1998-01-01

    Purpose: An accurate method for monitoring oxygen tension (pO 2 ) of individual tumors could be valuable for optimizing treatment plans. We have recently shown that 19 F nuclear magnetic resonance (NMR) spin-lattice relaxometry of hexafluorobenzene (HFB) provides a highly sensitive indicator of tumor oxygenation. We have now refined the methodology to provide enhanced precision, and applied the method to investigate dynamic changes in tumor oxygenation. Methods and Materials: Dunning prostate adenocarcinoma R3327-AT1 was grown in the form of pedicles on the foreback of male Copenhagen rats. When the tumors reached ≅1 cm diameter, HFB (20 μl) was administered, either centrally or peripherally, by direct intratumoral (IT) injection. Local pO 2 was determined using pulse-burst saturation recovery (PBSR) 19 F NMR spectroscopy on the basis of the spin-lattice relaxation rate, R1. Results: Interrogation of the central region of tumors provided typical values in the range pO 2 = 1.4-6.4 mmHg, with a typical stability of ±2 mmHg over a period of 20 min, when rats breathed 33% O 2 . Altering the inhaled gas to oxygen or carbogen (95% O 2 /5% CO 2 ) produced no significant change. In contrast, interrogation of tumor periphery indicated baseline pO 2 in the range 7.9-78.9 mmHg. Altering inspired gas produced significant changes (p 2 or carbogen, although the change was generally greater with carbogen. In each case, pO 2 returned to baseline within 16 min of returning the inhaled gas to baseline. Conclusion: We believe this method provides a valuable new approach with the requisite precision and accuracy to investigate tumor pO 2

  13. Cerebral and Renal Oxygen Saturation Are Not Compromised in the Presence of Retrograde Blood Flow in either the Ascending or Descending Aorta in Term or Near-Term Infants with Left-Sided Obstructive Lesions.

    Science.gov (United States)

    van der Laan, Michelle E; Mebius, Mirthe J; Roofthooft, Marcus T R; Bos, Arend F; Berger, Rolf M F; Kooi, Elisabeth M W

    2017-01-01

    In infants with left-sided obstructive lesions (LSOL), the presence of retrograde blood flow in either the ascending or descending aorta may lead to diminished cerebral and renal blood flow, respectively. Our aim was to compare cerebral and renal tissue oxygen saturation (rSO2) between infants with LSOL with antegrade and retrograde blood flow in the ascending aorta and with and without diastolic backflow in the descending aorta. Based on 2 echocardiograms, the study group was categorized according to the direction of blood flow in the ascending and descending aorta. We measured cerebral and renal rSO2 using near-infrared spectroscopy and calculated fractional tissue oxygen extraction (FTOE). Nineteen infants with LSOL, admitted to the NICU between 0 and 28 days after birth, were included. Infants with antegrade blood flow (n = 12) and infants with retrograde blood flow in the ascending aorta (n = 7) had similar cerebral rSO2 and FTOE during both echocardiograms. Only during the first echocardiogram, infants with retrograde blood flow in the ascending aorta had lower renal FTOE (0.14 vs. 0.32, p = 0.04) and tended to have higher renal rSO2 (80 vs. 65%, p = 0.09). The presence of diastolic backflow in the descending aorta was not associated with cerebral or renal rSO2 and FTOE during the first (n = 8) as well as the second echocardiogram (n = 10). Retrograde blood flow in the ascending aorta was not associated with cerebral oxygenation, while diastolic backflow in the descending aorta was not associated with renal oxygenation in infants with LSOL. © 2017 S. Karger AG, Basel.

  14. Effect of oxygen fugacity on OH dissolution in olivine under peridotite-saturated conditions: An experimental study at 1.5-7 GPa and 1100-1300 °C

    Science.gov (United States)

    Yang, Xiaozhi

    2016-01-01

    The dissolution of OH in olivine by experimental studies at simulated conditions has attracted increasing interest over the past three decades, and the influence of pressure, temperature and composition has been relatively well constrained. Oxygen fugacity is highly heterogeneous in the upper mantle, on both temporal and spatial scales, and is an important parameter in characterizing many chemical and physical processes in the mantle. However, less attention has been devoted to the effect of oxygen fugacity on OH dissolution in olivine, and the only few available reports on this topic have led to significant inconsistency and debate. In this study, the correlation between oxygen fugacity and OH solubility in Fe-bearing olivine has been systematically investigated by conducting experiments at 1.5-7 GPa and 1100-1300 °C and under peridotite- and fluid-saturated conditions, with natural gem-quality olivine single crystals and fresh peridotite xenoliths as starting materials and with oxygen fugacity controlled by the Fe-FeO, Ni-NiO and Fe2O3-Fe3O4 oxygen buffer pairs. The water concentrations were determined by polarized analyses using a Fourier-transform infrared spectroscopy. The results show that, at all the experimental conditions, the OH bands at both high frequency (∼3650-3450 cm-1) and low frequency (∼3450-3100 cm-1) are prominent. The intensity of OH bands at ∼3355 and 3325 cm-1 increases positively with oxygen fugacity, suggesting a dominant role of Fe3+ in their incorporation. Under otherwise identical conditions, the water content is gradually enhanced with increasing pressure, temperature or oxygen fugacity. The effect of oxygen fugacity on the enhancement of OH solubility appears not sensitive to temperature (1100-1300 °C) at a given pressure, but becomes progressively stronger with increasing pressure from 1.5 to 7 GPa given the temperature. Relative to oxygen fugacity buffers, the OH solubility is on average increased by ∼50% between Fe-FeO and

  15. Data on the effect of target temperature management at 32–34 °C in cardiac arrest patients considering assessment by regional cerebral oxygen saturation: A multicenter retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Yuka Nakatani

    2018-04-01

    Full Text Available This data article contains raw data and supplementary analyzed data regarding to the article entitled “Effect of target temperature management at 32–34 °C in cardiac arrest patients considering assessment by regional cerebral oxygen saturation: A multicenter retrospective cohort study”. We examined the effectiveness of target temperature management (TTM at 32–34 °C considering degrees of patients’ cerebral injury and cerebral circulation assessed by regional cerebral oxygen saturation (rSO2. The research is a secondary analysis of prospectively collected registry, in which comatose patients who were transferred to 15 hospitals in Japan after out-of-hospital cardiac arrest (OHCA, and we included 431 study patients. Propensity score analysis revealed that TTM at 32–34 °C decreased all-cause mortality in patients with rSO2 41–60%, and increased favorable neurological outcomes in patients with rSO2 41–60% in the original research article. With regard to the balance of covariates of propensity-score matching (PSM and inverse-probability weighting (IPW analyses, some covariates were not well balanced after the analyses between groups. The overlap plots indicate the overlap of densities of the propensity scores are low in group rSO2 41–60% and group rSO2 ≥ 61%. When patients were limited to those who achieved return of spontaneous circulation (ROSC until/on hospitals arrival, TTM still tended to decrease all-cause mortality and increase favorable outcomes in group rSO2 41–60%.

  16. Evaluating predictions of critical oxygen desaturation events

    International Nuclear Information System (INIS)

    ElMoaqet, Hisham; Tilbury, Dawn M; Ramachandran, Satya Krishna

    2014-01-01

    This paper presents a new approach for evaluating predictions of oxygen saturation levels in blood ( SpO 2 ). A performance metric based on a threshold is proposed to evaluate  SpO 2 predictions based on whether or not they are able to capture critical desaturations in the  SpO 2 time series of patients. We use linear auto-regressive models built using historical  SpO 2 data to predict critical desaturation events with the proposed metric. In 20 s prediction intervals, 88%–94% of the critical events were captured with positive predictive values (PPVs) between 90% and 99%. Increasing the prediction horizon to 60 s, 46%–71% of the critical events were detected with PPVs between 81% and 97%. In both prediction horizons, more than 97% of the non-critical events were correctly classified. The overall classification capabilities for the developed predictive models were also investigated. The area under ROC curves for 60 s predictions from the developed models are between 0.86 and 0.98. Furthermore, we investigate the effect of including pulse rate (PR) dynamics in the models and predictions. We show no improvement in the percentage of the predicted critical desaturations if PR dynamics are incorporated into the  SpO 2 predictive models (p-value = 0.814). We also show that including the PR dynamics does not improve the earliest time at which critical  SpO 2 levels are predicted (p-value = 0.986). Our results indicate oxygen in blood is an effective input to the PR rather than vice versa. We demonstrate that the combination of predictive models with frequent pulse oximetry measurements can be used as a warning of critical oxygen desaturations that may have adverse effects on the health of patients. (paper)

  17. Pulse oximetry in family practice: indications and clinical observations in patients with COPD.

    NARCIS (Netherlands)

    Schermer, T.R.J.; Leenders, J.L.H.; Veen, H. in 't; Bosch, W.J.H.M. van den; Wissink, A.; Smeele, I.J.M.; Chavannes, N.H.

    2009-01-01

    PURPOSE: To establish situations in which family physicians (FPs) consider pulse oximetry a valuable addition to their clinical patient assessment; to explore pulse oximetry results (SpO(2)) when used by FPs in patients with chronic obstructive pulmonary disease (COPD); to explore associations

  18. Lost without trace: oximetry signal dropout in preterm infants.

    Science.gov (United States)

    Lim, Kathleen; Wheeler, Kevin I; Jackson, Hamish D; Sadeghi Fathabadi, Omid; Gale, Timothy J; Dargaville, Peter A

    2015-09-01

    Oxygen saturation (SpO2) signal dropout leaves caregivers without a reliable measure to guide oxygen therapy. We studied SpO2 dropout in preterm infants on continuous positive airway pressure, noting the SpO2 values at signal loss and recovery and thus the resultant change in SpO2, and the factors influencing this parameter. In 32 infants of median gestation 26 weeks, a total of 3932 SpO2 dropout episodes were identified (1.1 episodes/h). In the episodes overall, SpO2 decreased by 1.1%, with the SpO2 change influenced by starting SpO2 (negative correlation), but not dropout duration. For episodes starting in hypoxia (SpO2 dropout, with a downward trajectory in a quarter of cases. We conclude that after signal dropout SpO2 generally recovers in a relative normoxic range. Blind FiO2 adjustments are thus unlikely to be of benefit during most SpO2 dropout episodes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Comparison the Effects of Shallow and Deep Endotracheal Tube Suctioning on Respiratory Rate, Arterial Blood Oxygen Saturation and Number of Suctioning in Patients Hospitalized in the Intensive Care Unit: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasinia

    2014-09-01

    Full Text Available Introduction: Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR, arterial blood oxygen saturation (SpO2 and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. Methods: In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA, chi-square and independent t-tests. Results: RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion: Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient’s trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  20. Comparison the effects of shallow and deep endotracheal tube suctioning on respiratory rate, arterial blood oxygen saturation and number of suctioning in patients hospitalized in the intensive care unit: a randomized controlled trial.

    Science.gov (United States)

    Abbasinia, Mohammad; Irajpour, Alireza; Babaii, Atye; Shamali, Mehdi; Vahdatnezhad, Jahanbakhsh

    2014-09-01

    Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR), arterial blood oxygen saturation (SpO2) and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA), chi-square and independent t-tests. RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion : Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  1. Soil aquifer treatment of artificial wastewater under saturated conditions

    KAUST Repository

    Essandoh, H. M K; Tizaoui, Chedly; Mohamed, Mostafa H A; Amy, Gary L.; Brdjanovic, Damir

    2011-01-01

    A 2000 mm long saturated laboratory soil column was used to simulate soil aquifer treatment under saturated conditions to assess the removal of chemical and biochemical oxygen demand (COD and BOD), dissolved organic carbon (DOC), nitrogen

  2. Assessing diabetic foot ulcer development risk with hyperspectral tissue oximetry

    Science.gov (United States)

    Yudovsky, Dmitry; Nouvong, Aksone; Schomacker, Kevin; Pilon, Laurent

    2011-02-01

    Foot ulceration remains a serious health concern for diabetic patients and has a major impact on the cost of diabetes treatment. Early detection and preventive care, such as offloading or improved hygiene, can greatly reduce the risk of further complications. We aim to assess the use of hyperspectral tissue oximetry in predicting the risk of diabetic foot ulcer formation. Tissue oximetry measurements are performed during several visits with hyperspectral imaging of the feet in type 1 and 2 diabetes mellitus subjects that are at risk for foot ulceration. The data are retrospectively analyzed at 21 sites that ulcerated during the course of our study and an ulceration prediction index is developed. Then, an image processing algorithm based on this index is implemented. This algorithm is able to predict tissue at risk of ulceration with a sensitivity and specificity of 95 and 80%, respectively, for images taken, on average, 58 days before tissue damage is apparent to the naked eye. Receiver operating characteristic analysis is also performed to give a range of sensitivity/specificity values resulting in a Q-value of 89%.

  3. Influence of Cholesterol on the Oxygen Permeability of Membranes: Insight from Atomistic Simulations.

    Science.gov (United States)

    Dotson, Rachel J; Smith, Casey R; Bueche, Kristina; Angles, Gary; Pias, Sally C

    2017-06-06

    Cholesterol is widely known to alter the physical properties and permeability of membranes. Several prior works have implicated cell membrane cholesterol as a barrier to tissue oxygenation, yet a good deal remains to be explained with regard to the mechanism and magnitude of the effect. We use molecular dynamics simulations to provide atomic-resolution insight into the influence of cholesterol on oxygen diffusion across and within the membrane. Our simulations show strong overall agreement with published experimental data, reproducing the shapes of experimental oximetry curves with high accuracy. We calculate the upper-limit transmembrane oxygen permeability of a 1-palmitoyl,2-oleoylphosphatidylcholine phospholipid bilayer to be 52 ± 2 cm/s, close to the permeability of a water layer of the same thickness. With addition of cholesterol, the permeability decreases somewhat, reaching 40 ± 2 cm/s at the near-saturating level of 62.5 mol % cholesterol and 10 ± 2 cm/s in a 100% cholesterol mimic of the experimentally observed noncrystalline cholesterol bilayer domain. These reductions in permeability can only be biologically consequential in contexts where the diffusional path of oxygen is not water dominated. In our simulations, cholesterol reduces the overall solubility of oxygen within the membrane but enhances the oxygen transport parameter (solubility-diffusion product) near the membrane center. Given relatively low barriers to passing from membrane to membrane, our findings support hydrophobic channeling within membranes as a means of cellular and tissue-level oxygen transport. In such a membrane-dominated diffusional scheme, the influence of cholesterol on oxygen permeability is large enough to warrant further attention. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  4. Rearfoot Transcutaneous Oximetry is a Useful Tool to Highlight Ischemia of the Heel

    Energy Technology Data Exchange (ETDEWEB)

    Izzo, Valentina, E-mail: valentina-izzo@virgilio.it; Meloni, Marco, E-mail: meloni.marco@libero.it [University of Tor Vergata, Department of Systems Medicine (Italy); Fabiano, Sebastiano, E-mail: sebas575@yahoo.it; Morosetti, Daniele, E-mail: danielemorosetti@hotmail.com [University of Tor Vergata, Department of Diagnostic Imaging and Interventional Radiology (Italy); Giurato, Laura, E-mail: lauragiurato@yahoo.it [University of Tor Vergata, Department of Systems Medicine (Italy); Chiaravalloti, Antonio, E-mail: antoniochiaravalloti@hotmail.it [University of Tor Vergata, Department of Diagnostic Imaging and Interventional Radiology (Italy); Ruotolo, Valeria, E-mail: valeriaruotolo@virgilio.it [University of Tor Vergata, Department of Systems Medicine (Italy); Gandini, Roberto, E-mail: roberto.gandini@fastwebnet.it [University of Tor Vergata, Department of Diagnostic Imaging and Interventional Radiology (Italy); Uccioli, Luigi, E-mail: luccioli@yahoo.com [University of Tor Vergata, Department of Systems Medicine (Italy)

    2017-01-15

    PurposeTo demonstrate the usefulness of rearfoot transcutaneous oximetry to assess the peripheral arterial disease in diabetic patients with heel ulcer.MethodsFrom our database of 550 critical limb ischemia diabetic patients followed after a percutaneous transluminal angioplasty, we have selected patients with below the knee arterial disease. Patients were grouped according to the dorsal transcutaneous oximetry value (Group A < 30 mmHg; Group B ≥ 30 mmHg). Patients of Group B had a second oximetry performed at the rearfoot, close to the lesion localized in all cases at the heel. Finally, the analysis of the arterial pattern disease has been done.ResultsWe selected 191 patients: Group A (151 patients), dorsal transcutaneous oximetry of 11.8 ± 0.7 mmHg; Group B (40 patients), dorsal transcutaneous oximetry of 44.2 ± 10.1 mmHg. In Group B, rearfoot oximetry was 20.5 ± 5 mmHg, significantly lower than dorsal oximetry (p = 0.0179). The anterior tibial artery was involved in all patients of Group A. In Group B, the anterior tibial artery was involved in 15 subjects and never alone; the posterior tibial artery was involved in 20 subjects and in 11 cases alone. The peroneal artery was affected in 20 subjects and in 14 patients alone.ConclusionWhen a heel lesion is present and the transcutaneous oximetry recorded on the dorsum of the foot does not confirm the presence of critical limb ischemia (not ≤30 mmHg), a second oximetry recorded on the rearfoot is useful to point out ischemia of the peroneal artery and/or of the posterior tibial artery.

  5. Rearfoot Transcutaneous Oximetry is a Useful Tool to Highlight Ischemia of the Heel

    International Nuclear Information System (INIS)

    Izzo, Valentina; Meloni, Marco; Fabiano, Sebastiano; Morosetti, Daniele; Giurato, Laura; Chiaravalloti, Antonio; Ruotolo, Valeria; Gandini, Roberto; Uccioli, Luigi

    2017-01-01

    PurposeTo demonstrate the usefulness of rearfoot transcutaneous oximetry to assess the peripheral arterial disease in diabetic patients with heel ulcer.MethodsFrom our database of 550 critical limb ischemia diabetic patients followed after a percutaneous transluminal angioplasty, we have selected patients with below the knee arterial disease. Patients were grouped according to the dorsal transcutaneous oximetry value (Group A < 30 mmHg; Group B ≥ 30 mmHg). Patients of Group B had a second oximetry performed at the rearfoot, close to the lesion localized in all cases at the heel. Finally, the analysis of the arterial pattern disease has been done.ResultsWe selected 191 patients: Group A (151 patients), dorsal transcutaneous oximetry of 11.8 ± 0.7 mmHg; Group B (40 patients), dorsal transcutaneous oximetry of 44.2 ± 10.1 mmHg. In Group B, rearfoot oximetry was 20.5 ± 5 mmHg, significantly lower than dorsal oximetry (p = 0.0179). The anterior tibial artery was involved in all patients of Group A. In Group B, the anterior tibial artery was involved in 15 subjects and never alone; the posterior tibial artery was involved in 20 subjects and in 11 cases alone. The peroneal artery was affected in 20 subjects and in 14 patients alone.ConclusionWhen a heel lesion is present and the transcutaneous oximetry recorded on the dorsum of the foot does not confirm the presence of critical limb ischemia (not ≤30 mmHg), a second oximetry recorded on the rearfoot is useful to point out ischemia of the peroneal artery and/or of the posterior tibial artery.

  6. Long-term oxygen therapy for COPD. Improving longevity and quality of life in hypoxemic patients.

    Science.gov (United States)

    Weg, J G; Haas, C F

    1998-04-01

    Long-term oxygen therapy can increase life expectancy in hypoxemic patients with COPD. Accurate identification of hypoxemia requires arterial blood gas measurements. Pulse oximetry can be used to measure trends in oxygenation, oxygen needs, and oxygen requirements during exercise and sleep. A detailed oxygen prescription indicates: (1) the oxygen dose (L/min), (2) the number of hours per day that oxygen therapy is required, (3) the dose required during exercise, (4) the oxygen supply system: concentrator, compressed gas cylinder, or liquid oxygen reservoir, and (5) the delivery device: nasal cannula, demand-flow device, reservoir cannula, or transtracheal oxygen catheter.

  7. Using pulse oximetry to account for high and low frequency physiological artifacts in the BOLD signal.

    Science.gov (United States)

    Verstynen, Timothy D; Deshpande, Vibhas

    2011-04-15

    The BOLD signal not only reflects changes in local neural activity, but also exhibits variability from physiological processes like cardiac rhythms and breathing. We investigated how both of these physiological sources are reflected in the pulse oximetry (PO) signal, a direct measure of blood oxygenation, and how this information can be used to account for different types of noise in the BOLD response. Measures of heart rate, respiration and PO were simultaneously recorded while neurologically healthy participants performed an eye-movement task in a 3T MRI. PO exhibited power in frequencies that matched those found in the independently recorded cardiac and respiration signals. Using the phasic and aphasic properties of these signals as nuisance regressors, we found that the different frequency components of the PO signal could be used to identify different types of physiological artifacts in the BOLD response. A comparison of different physiological noise models found that a simple, down-sampled version of the PO signal improves the estimation of task-relevant statistics nearly as well as more established noise models that may run the risk of over-parameterization. These findings suggest that the PO signal captures multiple sources of physiological noise in the BOLD response and provides a simple and efficient way of modeling these noise sources in subsequent analysis. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. EPR Oximetry for Investigation of Hyperbaric O2 Pre-treatment for Tumor Radiosensitization.

    Science.gov (United States)

    Williams, Benjamin B; Hou, Huagang; Coombs, Rachel; Swartz, Harold M

    A number of studies have reported benefits associated with the application of hyperbaric oxygen treatment (HBO) delivered immediately prior to radiation therapy. While these studies provide evidence that pre-treatment with HBO may be beneficial, no measurements of intratumoral pO2 were carried out and they do not directly link the apparent benefits to decreased hypoxic fractions at the time of radiation therapy. While there is empirical evidence and some theoretical basis for HBO to enhance radiation therapy, without direct and repeated measurements of its effects on pO2, it is unlikely that the use of HBO can be understood and optimized for clinical applications. In vivo EPR oximetry is a technique uniquely capable of providing repeated direct measurements of pO2 through a non-invasive procedure in both animal models and human patients. In order to evaluate the ability of pretreatment with HBO to elevate tumor pO2, a novel small animal hyperbaric chamber system was constructed that allows simultaneous in vivo EPR oximetry. This chamber can be placed within the EPR magnet and is equipped with a variety of ports for multiplace gas delivery, thermoregulation, delivery of anesthesia, physiologic monitoring, and EPR detection. Initial measurements were performed in a subcutaneous RIF-1 tumor model in C3H/HeJ mice. The mean baseline pO2 value was 6.0 ± 1.2 mmHg (N = 7) and responses to two atmospheres absolute pressure HBO varied considerably across subjects, within tumors, and over time. When an increase in pO2 was observed, the effect was transient in all but one case, with durations lasting from 5 min to over 20 min, and returned to baseline levels during HBO administration. These results indicate that without direct measurements of pO2 in the tissue of interest, it is likely to be difficult to know the effects of HBO on actual tissue pO2.

  9. Oximetry: A Reflective Tool for the Detection of Physiological Expression of Emotions in a Science Education Classroom

    Science.gov (United States)

    Calderón, Olga

    2016-01-01

    The pulse oximeter is a device that measures the oxygen concentration (or oxygen saturation--SpO[subscript 2]); heart rate, and heartbeat of a person at any given time. This instrument is commonly used in medical and aerospace fields to monitor physiological outputs of a patient according to health conditions or physiological yields of a flying…

  10. Seven-day mortality can be predicted in medical patients by blood pressure, age, respiratory rate, loss of independence, and peripheral oxygen saturation (the PARIS score: a prospective cohort study with external validation.

    Directory of Open Access Journals (Sweden)

    Mikkel Brabrand

    Full Text Available Most existing risk stratification systems predicting mortality in emergency departments or admission units are complex in clinical use or have not been validated to a level where use is considered appropriate. We aimed to develop and validate a simple system that predicts seven-day mortality of acutely admitted medical patients using routinely collected variables obtained within the first minutes after arrival.This observational prospective cohort study used three independent cohorts at the medical admission units at a regional teaching hospital and a tertiary university hospital and included all adult (≥ 15 years patients. Multivariable logistic regression analysis was used to identify the clinical variables that best predicted the endpoint. From this, we developed a simplified model that can be calculated without specialized tools or loss of predictive ability. The outcome was defined as seven-day all-cause mortality. 76 patients (2.5% met the endpoint in the development cohort, 57 (2.0% in the first validation cohort, and 111 (4.3% in the second. Systolic blood Pressure, Age, Respiratory rate, loss of Independence, and peripheral oxygen Saturation were associated with the endpoint (full model. Based on this, we developed a simple score (range 0-5, ie, the PARIS score, by dichotomizing the variables. The ability to identify patients at increased risk (discriminatory power and calibration was excellent for all three cohorts using both models. For patients with a PARIS score ≥ 3, sensitivity was 62.5-74.0%, specificity 85.9-91.1%, positive predictive value 11.2-17.5%, and negative predictive value 98.3-99.3%. Patients with a score ≤ 1 had a low mortality (≤ 1%; with 2, intermediate mortality (2-5%; and ≥ 3, high mortality (≥ 10%.Seven-day mortality can be predicted upon admission with high sensitivity and specificity and excellent negative predictive values.

  11. Transcutaneous oximetry compared to ankle-brachial-index measurement in the evaluation of percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Wildgruber, Moritz; Wolf, Oliver; Weiss, Wolfgang; Berger, Hermann; Lutzenberger, Werner; Eckstein, Hans-Henning; Heider, Peter

    2007-01-01

    Objective: To investigate transcutaneous oximetry as parameter of the microcirculation is correlated to ankle-brachial-index as parameter of the macrocirculation after peripheral angioplasty procedures. Design: Prospective study. Materials and methods: 60 patients suffering from intermittent claudication were scheduled for angioplasty treatment. 45 patients were considered as eligible for angioplasty after angiographic evaluation, 15 patients underwent angiography only. Transcutaneous oximetry measurements were performed before the procedure, at the end of intervention, 24 h as well as 2 and 4 weeks after percutaneous transluminal angioplasty. Ankle-brachial-indices were obtained before intervention, 24 h as well as 2 and 4 weeks later. Results: Ankle-brachial-indices increased significantly at 24 h after angioplasty in patients being treated with angioplasty. Transcutaneous oximetry values dropped significantly at the end of the procedure and returned close to the baseline levels at 2 and 4 weeks after angioplasty. Ankle-brachial-indices and transcutaneous oximetry were positively correlated before (r = 0.3833, p = 0.009) as well as 4 weeks after angioplasty (r = 0.4596, p = 0.001). Immediately after radiological interventions, ankle-brachial-indices and transcutaneous oximetry are not positively correlated. In patients undergoing angiography only, transcutaneous oximetry levels drop significantly immediately after angiography and remain at decreased levels even at 4 weeks after intervention. Conclusion: Transcutaneous oximetry as parameter of the microcirculation is positively correlated with ankle-brachial-index as parameter of the macrocirculation before and at 4 weeks after angioplasty. Intraarterial angiography leads to a sudden decrease in skin microcirculation without affecting macrocirculation. As indicated by a lack of recovery in transcutaneous oximetry levels after 4 weeks, angiography alone results in a prolonged impaired microcirculation which may

  12. Oximetry: a reflective tool for the detection of physiological expression of emotions in a science education classroom

    Science.gov (United States)

    Calderón, Olga

    2016-09-01

    The pulse oximeter is a device that measures the oxygen concentration (or oxygen saturation—SpO2); heart rate, and heartbeat of a person at any given time. This instrument is commonly used in medical and aerospace fields to monitor physiological outputs of a patient according to health conditions or physiological yields of a flying pilot according to changes in altitude and oxygen availability in the atmosphere. Nonetheless, the uses for pulse oximetry may expand to other fields where there is human interaction and where physiological outputs reflect fluctuations mediated by arising emotions. A classroom, for instance is filled with a plethora of emotions, but very often participants in this space are unaware of others' or their own sentiments as these arise as a result of interactions and responses to class discussions. In this paper I describe part of a larger study-taking place at Brooklyn College of the City University of New York. The focus is on the exploration of emotions and mindfulness in the science classroom. The oximeter is used in this study as a reflexive tool to detect emotions emerging among participants of a graduate History and Philosophy of Science Education course offered in the spring of 2012. Important physiological information of class participants provided by the oximeter is used to analyze the role of emotions in the classroom as sensitive and controversial topics in science education are discussed every week.

  13. Single-cell measurement of red blood cell oxygen affinity

    OpenAIRE

    Caprio, Di; Stokes, Chris; Higgins, John M.; Schonbrun, Ethan

    2015-01-01

    Oxygen is transported throughout the body by hemoglobin in red blood cells. While the oxygen affinity of blood is well understood and is routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of red blood cell volume and hemoglobin concentration are taken millions of times per day by clinical hematology analyzers and are important factors in determining the health of the hematologic system....

  14. In vivo colocalization of 2-nitroimidazole EF5 fluorescence intensity and electron paramagnetic resonance oximetry in mouse tumors

    International Nuclear Information System (INIS)

    Mahy, Pierre; Bast, Marc de; Gallez, Bernard; Gueulette, John; Koch, Cameron J.; Scalliet, Pierre; Gregoire, Vincent

    2003-01-01

    Background and purpose: The primary objective of this study was to establish in vivo the relationship between 2-2-nitro-1H-imidazol-1yl-N-(2,2,3,3,3-pentafluoropropyl)-acetamide (EF5) adduct formation and intratumoral oxygen concentrations measured by electron paramagnetic resonance (EPR) in a tumor model mimicking a clinical situation. The secondary objective was an attempt to calibrate in situ the immunofluorescence (IF) signal with EPR oximetry. Materials and methods: IM syngeneic fibrosarcoma (NFSA) bearing C3H mice were used. Three days after injection of a paramagnetic charcoal into the tumor, the mice were anesthetized, injected with the hypoxic marker EF5, and monitored every 20 min for 3 h with a low-frequency EPR spectrometer. Animals were allowed to breath either under 21 or 100% O 2 . Tumors were then harvested, frozen, cut into sections including the charcoal and processed for EF5 adducts detection using monoclonal antibodies. Slices were viewed with a fluorescence microscope and 190x140 μm areas surrounding the charcoal were digitized and analyzed with the NIH-Image and Adobe Photoshop TM software. The fluorescence intensity (FI) was measured in the whole pictures and in strips of 10 μm around the charcoal. Results: EF5 binding increased with decreasing pO 2 , most substantially at pO 2 below 5 mm Hg. Baseline (ambient air) pO 2 reached 3.2±2.1 mm Hg in NFSA tumors. It increased to 9.8±3.2 mm Hg under 100% O 2 . A statistically significant correlation was observed on an individual tumor basis between the FI in the first 10 μm strip around the charcoal and the pO 2 determined by EPR oximetry (Wilcoxon signed rank test: P 2 in an in vivo environment under biologically-relevant pO 2 values of less than 10 mm Hg

  15. Oxygen therapy reduces postoperative tachycardia

    DEFF Research Database (Denmark)

    Stausholm, K; Kehlet, H; Rosenberg, J

    1995-01-01

    Concomitant hypoxaemia and tachycardia in the postoperative period is unfavourable for the myocardium. Since hypoxaemia per se may be involved in the pathogenesis of postoperative tachycardia, we have studied the effect of oxygen therapy on tachycardia in 12 patients randomly allocated to blinded...... air or oxygen by facemask on the second or third day after major surgery. Inclusion criteria were arterial hypoxaemia (oxygen saturation 90 beat.min-1). Each patient responded similarly to oxygen therapy: an increase in arterial oxygen saturation and a decrease...... in heart rate (p oxygen has a positive effect on the cardiac oxygen delivery and demand balance....

  16. Wavelength selection method with standard deviation: application to pulse oximetry.

    Science.gov (United States)

    Vazquez-Jaccaud, Camille; Paez, Gonzalo; Strojnik, Marija

    2011-07-01

    Near-infrared spectroscopy provides useful biological information after the radiation has penetrated through the tissue, within the therapeutic window. One of the significant shortcomings of the current applications of spectroscopic techniques to a live subject is that the subject may be uncooperative and the sample undergoes significant temporal variations, due to his health status that, from radiometric point of view, introduce measurement noise. We describe a novel wavelength selection method for monitoring, based on a standard deviation map, that allows low-noise sensitivity. It may be used with spectral transillumination, transmission, or reflection signals, including those corrupted by noise and unavoidable temporal effects. We apply it to the selection of two wavelengths for the case of pulse oximetry. Using spectroscopic data, we generate a map of standard deviation that we propose as a figure-of-merit in the presence of the noise introduced by the living subject. Even in the presence of diverse sources of noise, we identify four wavelength domains with standard deviation, minimally sensitive to temporal noise, and two wavelengths domains with low sensitivity to temporal noise.

  17. Oximetry and indications for tracheotomy for amyotrophic lateral sclerosis.

    Science.gov (United States)

    Bach, John Robert; Bianchi, Carlo; Aufiero, Elaine

    2004-11-01

    To explore the use of oximetry as a guide for using respiratory aids and tracheotomy in the treatment of patients with amyotrophic lateral sclerosis (ALS). A retrospective review of all ALS patients presenting to a neuromuscular disease clinic since 1996. Patients who were symptomatic for nocturnal hypoventilation were prescribed noninvasive ventilation (NIV). Patients with assisted cough peak flows of NIV and MAC and the duration of normalization were recorded. When the baseline was not or could not be normalized, the time to acute respiratory failure and tracheotomy or death were recorded. Twenty-five patients became dependent on NIV, including 13 patients who received NIV continuously for a mean (+/- SD) period of 19.7 +/- 16.9 months, without desaturation (group 1). For another 76 patients, the daytime baseline Spo(2) level decreased to NIV/MAC (group 2) for a mean duration of 11.1 +/- 8.7 months before desaturation reoccurred for 27 patients. Of the latter patients, 11 underwent tracheotomy, 14 died in NIV or MAC. The long-term use of NIV and MAC, and the avoidance of tracheotomy is dependent on glottic function rather than on inspiratory or expiratory muscle failure.

  18. The MOST - Monitor for Oxygenation of Surface and Tissue.

    Science.gov (United States)

    1995-10-01

    anesthesia Effectiveness of COR Bio-feedback for peripheral vasodilation Relationship of CPAP and PEEP to atelectasis Waveforms Diagnosis of irregularities...deliberate hypoxia in premature infants Servo-controlled saturation, prematures Converse 02 in home 02 therapy Determine optimal PEEP and CPAP Monitor...Kusakawa I, Ohata J, Kawano T, Honma Y. Use of Pulse Oximetry In Neonatal Anesthe- sia. J Perinatology. 1987:7;343-5. Nishimura S, Tomita Y, Horiuchi T

  19. Parental preference and perspectives on continuous pulse oximetry in infants and children with bronchiolitis

    Directory of Open Access Journals (Sweden)

    Hendaus MA

    2018-04-01

    Full Text Available Mohamed A Hendaus,1,2 Suzan Nassar,3 Bassil A Leghrouz,3 Ahmed H Alhammadi,1,2 Mohammed Alamri4 1Department of Pediatrics, Section of Academic General Pediatrics, Sidra Medicine, Doha, Qatar; 2Department of Clinical Pediatrics, Weill Cornell Medicine, Doha, Qatar; 3Department of Pediatrics, Hamad General Corporation, Doha, Qatar; 4Pediatric Emergency Center, Hamad General Corporation, Doha, Qatar Objective: The purpose of the study was to investigate parental preference of continuous pulse oximetry in infants and children with bronchiolitis. Materials and methods: A cross-sectional prospective study was conducted at Hamad Medical Corporation in Qatar. Parents of infants and children <24 months old and hospitalized with bronchiolitis were offered an interview survey. Results: A total of 132 questionnaires were completed (response rate 100%. Approximately 90% of participants were 20–40 years of age, and 85% were females. The mean age of children was 7.2±5.8 months. Approximately eight in ten parents supported the idea of continuous pulse oximetry in children with bronchiolitis. Almost 43% of parents believed that continuous pulse-oximetry monitoring would delay their children’s hospital discharge. Interestingly, approximately 85% of caregivers agreed that continuous pulse oximetry had a good impact on their children’s health. In addition, around one in two of the participants stated that good bedside examinations can obviate the need for continuous pulse oximetry. Furthermore, 80% of parents believed that continuous pulse-oximetry monitoring would give the health-care provider a good sense of security regarding the child’s health. Finally, being a male parent was associated with significantly increased risk of reporting unnecessary fatigue, attributed to the sound of continuous pulse oximetry (P=0.031. Conclusion: Continuous pulse-oximetry monitoring in children with bronchiolitis was perceived as reassuring for parents. Involving parents

  20. A Meta-Analysis about the Screening Role of Pulse Oximetry for Congenital Heart Disease

    Directory of Open Access Journals (Sweden)

    Caiju Du

    2017-01-01

    Full Text Available Objective. The opinions about the application of pulse oximetry in diagnosis of congenital heart disease (CHD were debatable. We performed this meta-analysis to confirm the diagnostic role of pulse oximetry screening for CHD. Methods. Relevant articles were searched in the databases of Pubmed, Embase, Google Scholar, and Chinese National Knowledge Infrastructure (CNKI up to April 2017. Data was processed in the MetaDiSc 1.4 software. Pooled sensitivity and specificity with 95% confidence interval (95% CI were calculated to explain the diagnostic role of pulse oximetry screening for CHD. I2⩾50% or p<0.05 indicated significant heterogeneity. Area under curve (AUC of summary receiver operating characteristics (SROC was calculated to assess its diagnostic accuracy. The robustness of overall results was evaluated by sensitivity analysis. Publication bias was evaluated by Deek’s funnel plot. Results. 22 eligible articles were selected. Pooled sensitivity and specificity were 0.69 (0.67–0.72 and 0.99 (0.99-0.99, respectively. The corresponding AUC was 0.9407, suggesting high diagnostic accuracy of pulse oximetry screening for CHD. Sensitivity analysis demonstrated that the pooled results were robust. Deek’s funnel plot seemed to be symmetrical. Conclusions. Pulse oximetry screening could be used to diagnose CHD. It shows high diagnosis specificity and accuracy.

  1. RANCANG BANGUN PULSE OXIMETRY MENGGUNAKAN ARDUINO SEBAGAI DETEKSI KEJENUHAN OKSIGEN DALAM DARAH

    Directory of Open Access Journals (Sweden)

    Umi Salamah

    2016-12-01

    Full Text Available Kekurangan atau kelebihan oksigen dalam darah akan menimbulkan penyakit dan gangguan kerja tubuh. Pada tingkat tertentu, penyakit tersebut dapat meninbulkan resiko kematian. Oleh karena itu, informasi tentang kejenuhan oksigen dalam darah menjadi hal yang penting untuk dideteksi. Salah satu insturmentasi yang digunakan untuk memantau kejenuhan oksigen dalam darah adalah dengan pulse oximetry. Dalam penelitian ini dirancang bangun pulse oximetry berbasis personal computer menggunakan LED merah dan inframerah sebagai sumber cahaya sedang sensor cahaya yang digunakan adalah fotodioda. Pulse oximetry yang dirancang adalah instrumentasi non invasive yang mana driver LED diletakkan pada ujung jari. Cahaya LED yang terserap jari akan menjadi sinyal yang diumpankan ke fotodioda yang selanjutnya sinyal tersebut akan diubah menjadi sinyal digital oleh Arduino dan diproses lebih lanjut oleh personal computer untuk menampilkan grafik pulse oximetry tersebut. Perangkat lunak untuk mengolah data keluaran Arduino menggunakan Delphi 7, Microsoft Exel dan Mat Lab sebagai perangkat lunaknya. Hasil penelitian ini diperoleh sinyal Photopletysmography (PPG Ujung Jari yang representatif  dengan sinyal PPG referensi. Pengujian pulse oximetry yang telah dirancang adalah 16 dengan sampel uji random. Dari sampel tersebut, diperoleh 13 sampel uji berada pada prosentase kejenuhan oksigen normal dan 3 sampel uji berada pada prosentase kejenuhan oksigen tidak normal.

  2. Comparison of pre-workout nitric oxide stimulating dietary supplements on skeletal muscle oxygen saturation, blood nitrate/nitrite, lipid peroxidation, and upper body exercise performance in resistance trained men

    Directory of Open Access Journals (Sweden)

    Canale Robert E

    2010-05-01

    Full Text Available Abstract Background We compared Glycine Propionyl-L-Carnitine (GlycoCarn® and three different pre-workout nutritional supplements on measures of skeletal muscle oxygen saturation (StO2, blood nitrate/nitrite (NOx, lactate (HLa, malondialdehyde (MDA, and exercise performance in men. Methods Using a randomized, double-blind, cross-over design, 19 resistance trained men performed tests of muscular power (bench press throws and endurance (10 sets of bench press to muscular failure. A placebo, GlycoCarn®, or one of three dietary supplements (SUPP1, SUPP2, SUPP3 was consumed prior to exercise, with one week separating conditions. Blood was collected before receiving the condition and immediately after exercise. StO2 was measured during the endurance test using Near Infrared Spectroscopy. Heart rate (HR and rating of perceived exertion (RPE were determined at the end of each set. Results A condition effect was noted for StO2 at the start of exercise (p = 0.02, with GlycoCarn® higher than SUPP2. A condition effect was also noted for StO2 at the end of exercise (p = 0.003, with SUPP1 lower than all other conditions. No statistically significant interaction, condition, or time effects were noted for NOx or MDA (p > 0.05; however, MDA decreased 13.7% with GlycoCarn® and increased in all other conditions. Only a time effect was noted for HLa (p 0.05; however, GlycoCarn® resulted in a statistically insignificant greater total volume load compared to the placebo (3.3%, SUPP1 (4.2%, SUPP2 (2.5%, and SUPP3 (4.6%. Conclusion None of the products tested resulted in favorable changes in our chosen outcome measures, with the exception of GlycoCarn® in terms of higher StO2 at the start of exercise. GlycoCarn® resulted in a 13.7% decrease in MDA from pre- to post-exercise and yielded a non-significant but greater total volume load compared to all other conditions. These data indicate that 1 a single ingredient (GlycoCarn® can provide similar practical benefit

  3. Retinal oximetry during treatment of retinal vein occlusion by ranibizumab in patients with high blood pressure and dyslipidemia.

    Science.gov (United States)

    Keilani, C; Halalchi, A; Wakpi Djeugue, D; Regis, A; Abada, S

    2016-12-01

    In the present study, we examined retinal vascular oxygen saturation in patients with retinal vein occlusion (RVO), high blood pressure (HBP) and dyslipidemia, before and during intravitreal vascular endothelial growth factor (VEGF) injection (ranibizumab). We retrospectively reviewed the medical records of six patients with visual acuity (VA) reduced by macular edema (ME) secondary to RVO with HBP and dyslipidemia, who underwent intravitreal anti-VEGF injection between October 2014 and February 2015 in the department of ophthalmology of François-Quesnay Hospital at Mantes-la-Jolie (France). The main inclusion criterion was the presence of RVO with ME and decreased VA. The primary endpoint was improvement of retinal venous oxygen saturation in patients with RVO before and 3 months after intravitreal ranibizumab injection. Secondary outcomes were improvement of retinal arterial oxygen saturation, improvement of best-corrected visual acuity (BCVA) on the Early Treatment Diabetic Retinopathy Study (ETDRS) scale, regression of ME measured by the central macular thickness (CMT) in nm and studying the correlation between blood pressure (BP) and retinal venous oxygen saturation before and after ranibizumab. Six eyes of six patients were included. Before treatment, the mean (standard deviation [SD]) of the retinal venous saturation (%) was 38.1±14.2. Three months after the injections, the mean (SD) of the retinal venous saturation (%) increased statistically significantly 49.2±11 (P=0.03). In this study, retinal venous oxygen saturation in patients with RVO, HBP and dyslipidemia was partially normalized during intravitreal ranibizumab treatment. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  4. EFFECT OF MODERATE ALTITUDE ON PERIPHERAL MUSCLE OXYGENATION DURING LEG RESISTANCE EXERCISE IN YOUNG MALES

    Directory of Open Access Journals (Sweden)

    Toshio Matsuoka

    2004-09-01

    Full Text Available Training at moderate altitude (~1800m is often used by athletes to stimulate muscle hypoxia. However, limited date is available on peripheral muscle oxidative metabolism at this altitude (1800AL. The purpose of this study was to determine whether acute exposure to 1800AL alters muscle oxygenation in the vastus lateralis muscle during resistance exercise. Twenty young active male subjects (aged 16 - 21 yr performed up to 50 repetitions of the parallel squat at 1800AL and near sea level (SL. They performed the exercise protocol within 3 h after arrival at 1800 AL. During the exercise, the changes in oxygenated hemoglobin (OxyHb in the vastus lateralis muscle, arterial oxygen saturation (SpO2, and heart rate were measured using near infrared continuous wave spectroscopy (NIRcws and pulse oximetry, respectively. Changes in OxyHb were expressed by Deff defined as the relative index of the maximum change ratio (% from the resting level. OxyHb in the vastus lateralis muscle decreased dramatically from the resting level immediately after the start of exercise at both altitudes. The Deff during exercise was significantly (p < 0.001 lower at 1800AL (60.4 ± 6.2 % than at near SL (74.4 ± 7.6 %. SpO2 during exercise was significantly (p < 0.001 lower at 1800AL (92.0 ± 1.7 % than at near SL (96.7 ± 1.2 %. Differences (SL - 1800AL in Deff during exercise correlated fairly strongly with differences in SpO2 during exercise (r = 0.660. These results suggested that acute exposure to moderate altitude caused a more dramatical decrease in peripheral muscle oxygenation during leg resistance exercise. It is salient to note, therefore , that peripheral muscle oxygenation status at moderate altitude could be evaluated using NIRcws and that moderate altitudes might be effectively used to apply hypoxic stress on peripheral muscles.

  5. Assessment of the Changes in 9L and C6 Glioma pO2 by EPR Oximetry as a Prognostic Indicator of Differential Response to Radiotherapy

    Science.gov (United States)

    Hou, Huagang; Mupparaju, Sriram P.; Lariviere, Jean P.; Hodge, Sassan; Gui, Jiang; Swartz, Harold M.; Khan, Nadeem

    2013-01-01

    Tumor hypoxia impedes the outcome of radiotherapy. As the extent of hypoxia in solid tumors varies during the course of radiotherapy, methods that can provide repeated assessment of tumor pO2 such as EPR oximetry may enhance the efficacy of radiotherapy by scheduling irradiations when the tumors are oxygenated. The repeated measurements of tumor pO2 may also identify responders, and thereby facilitate the design of better treatment plans for nonresponding tumors. We have investigated the temporal changes in the ectopic 9L and C6 glioma pO2 irradiated with single radiation doses less than 10 Gy by EPR oximetry. The 9L and C6 tumors were hypoxic with pO2 of approximately 5–9 mmHg. The pO2 of C6 tumors increased significantly with irradiation of 4.8–9.3 Gy. However, no change in the 9L tumor pO2 was observed. The irradiation of the oxygenated C6 tumors with a second dose of 4.8 Gy resulted in a significant delay in growth compared to hypoxic and 2 Gy × 5 treatment groups. The C6 tumors with an increase in pO2 of greater than 50% from the baseline of irradiation with 4.8 Gy (responders) had a significant tumor growth delay compared to nonresponders. These results indicate that the ectopic 9L and C6 tumors responded differently to radiotherapy. We propose that the repeated measurement of the oxygen levels in the tumors during radiotherapy can be used to identify responders and to design tumor oxygen guided treatment plans to improve the outcome. PMID:23391148

  6. Assessment of the changes in 9L and C6 glioma pO2 by EPR oximetry as a prognostic indicator of differential response to radiotherapy.

    Science.gov (United States)

    Hou, Huagang; Mupparaju, Sriram P; Lariviere, Jean P; Hodge, Sassan; Gui, Jiang; Swartz, Harold M; Khan, Nadeem

    2013-03-01

    Tumor hypoxia impedes the outcome of radiotherapy. As the extent of hypoxia in solid tumors varies during the course of radiotherapy, methods that can provide repeated assessment of tumor pO2 such as EPR oximetry may enhance the efficacy of radiotherapy by scheduling irradiations when the tumors are oxygenated. The repeated measurements of tumor pO2 may also identify responders, and thereby facilitate the design of better treatment plans for nonresponding tumors. We have investigated the temporal changes in the ectopic 9L and C6 glioma pO2 irradiated with single radiation doses less than 10 Gy by EPR oximetry. The 9L and C6 tumors were hypoxic with pO2 of approximately 5-9 mmHg. The pO2 of C6 tumors increased significantly with irradiation of 4.8-9.3 Gy. However, no change in the 9L tumor pO2 was observed. The irradiation of the oxygenated C6 tumors with a second dose of 4.8 Gy resulted in a significant delay in growth compared to hypoxic and 2 Gy × 5 treatment groups. The C6 tumors with an increase in pO2 of greater than 50% from the baseline of irradiation with 4.8 Gy (responders) had a significant tumor growth delay compared to nonresponders. These results indicate that the ectopic 9L and C6 tumors responded differently to radiotherapy. We propose that the repeated measurement of the oxygen levels in the tumors during radiotherapy can be used to identify responders and to design tumor oxygen guided treatment plans to improve the outcome.

  7. Simultaneous use of intrapartum fetal pulse oximetry and amnioinfusion in meconium stained amniotic fluid.

    Science.gov (United States)

    Halvax, László; Szabó, István; Vizer, Miklós; Csermely, Tamás; Ertl, Tibor

    2002-09-10

    Fetal pulse oximetry is a minimally invasive, simple technique which continuously helps to reflect in utero well-being. The presence of meconium in the amniotic fluid may be a clinical sign of fetal hypoxaemia. Amnioinfusion has a beneficial effect on the incidence of meconium aspiration syndrome (MAS), and the presence of meconium below the level of the vocal cords. We studied the impact of amnioinfusion combined with fetal pulse oximetry on the incidence of meconium aspiration syndrome and operative delivery. The retrospective analysis revealed that the presence of meconium below the level of vocal cords was significantly reduced. The frequency of cesarean section is decreased, however, it did not reach statistical significance. Fetal pulse oximetry may be used in combination with amnioinfusion and cardiotocography (CTG) to reduce the risk of meconium aspiration syndrome and the number of instrumental deliveries and improve perinatal outcome. Copyright 2002 Elsevier Science Ireland Ltd.

  8. Cerebral blood flow and oximetry response to blood transfusion in relation to chronological age in preterm infants.

    Science.gov (United States)

    Banerjee, J; Leung, T S; Aladangady, N

    2016-06-01

    Preterm infants frequently receive blood transfusion (BT) and the aim of this study was to measure the effect of BT on cerebral blood flow and oxygenation in preterm infants in relation to chronological age. Preterm infants undergoing intensive care recruited to three chronological age groups: 1 to 7 (Group 1; n=20), 8 to 28 (Group 2; n=21) & ≥29days of life (Group 3; n=18). Pre and post-BT anterior cerebral artery (ACA) time averaged mean velocity (TAMV) and superior vena cava (SVC) flow were measured. Cerebral Tissue Haemoglobin Index (cTHI) and Oxygenation Index (cTOI) were measured from 15-20min before to 15-20min post-BT using NIRS. Vital parameters and blood pressure were measured continuously. Mean BP increased significantly, and there was no significant change in vital parameters following BT. Pre-BT ACA TAMV was higher in Group 2 and 3 compared to Group 1 (pBlood transfusion increased cTOI and cTHI and decreased ACA TAMV in all groups. PDA had no impact on the baseline cerebral oximetry and blood flow as well as changes following blood transfusion. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Measurements of pulmonary gas exchange efficiency using expired gas and oximetry: results in normal subjects.

    Science.gov (United States)

    West, John B; Wang, Daniel L; Prisk, G Kim

    2018-04-01

    We are developing a novel, noninvasive method for measuring the efficiency of pulmonary gas exchange in patients with lung disease. The patient wears an oximeter, and we measure the partial pressures of oxygen and carbon dioxide in inspired and expired gas using miniature analyzers. The arterial Po 2 is then calculated from the oximeter reading and the oxygen dissociation curve, using the end-tidal Pco 2 to allow for the Bohr effect. This calculation is only accurate when the oxygen saturation is ideal alveolar Po 2 minus the measured arterial Po 2 . That measurement requires an arterial blood sample. The present study suggests that this noninvasive procedure will be valuable in assessing the degree of impaired gas exchange in patients with lung disease.

  10. Pulse Oximetry and Auscultation for Congenital Heart Disease Detection.

    Science.gov (United States)

    Hu, Xiao-Jing; Ma, Xiao-Jing; Zhao, Qu-Ming; Yan, Wei-Li; Ge, Xiao-Ling; Jia, Bing; Liu, Fang; Wu, Lin; Ye, Ming; Liang, Xue-Cun; Zhang, Jing; Gao, Yan; Zhai, Xiao-Wen; Huang, Guo-Ying

    2017-10-01

    Pulse oximetry (POX) has been confirmed as a specific screening modality for critical congenital heart disease (CCHD), with moderate sensitivity. However, POX is not able to detect most serious and critical cardiac lesions (major congenital heart disease [CHD]) without hypoxemia. In this study, we investigated the accuracy and feasibility of the addition of cardiac auscultation to POX as a screening method for asymptomatic major CHD. A multicenter prospective observational screening study was conducted at 15 hospitals in Shanghai between July 1, 2012, and December 31, 2014. Newborns with either an abnormal POX or cardiac auscultation were defined as screen positive. All screen-positive newborns underwent further echocardiography. False-negative results were identified by clinical follow-up, parents' feedback, and telephone review. We assessed the accuracy of POX plus cardiac auscultation for the detection of major CHD. CHD screening was completed in all 15 hospitals, with a screening rate of 94.0% to 99.8%. In total, 167 190 consecutive asymptomatic newborn infants were screened, of which 203 had major CHD (44 critical and 159 serious). The sensitivity of POX plus cardiac auscultation was 95.5% (95% confidence interval 84.9%-98.7%) for CCHD and 92.1% (95% confidence interval 87.7%-95.1%) for major CHD. The false-positive rate was 1.2% for detecting CCHD and 1.1% for detecting major CHD. In our current study, we show that using POX plus cardiac auscultation significantly improved the detection rate of major CHD in the early neonatal stage, with high sensitivity and a reasonable false-positive rate. It provides strong evidence and a reliable method for neonatal CHD screening. Copyright © 2017 by the American Academy of Pediatrics.

  11. Saturated Switching Systems

    CERN Document Server

    Benzaouia, Abdellah

    2012-01-01

    Saturated Switching Systems treats the problem of actuator saturation, inherent in all dynamical systems by using two approaches: positive invariance in which the controller is designed to work within a region of non-saturating linear behaviour; and saturation technique which allows saturation but guarantees asymptotic stability. The results obtained are extended from the linear systems in which they were first developed to switching systems with uncertainties, 2D switching systems, switching systems with Markovian jumping and switching systems of the Takagi-Sugeno type. The text represents a thoroughly referenced distillation of results obtained in this field during the last decade. The selected tool for analysis and design of stabilizing controllers is based on multiple Lyapunov functions and linear matrix inequalities. All the results are illustrated with numerical examples and figures many of them being modelled using MATLAB®. Saturated Switching Systems will be of interest to academic researchers in con...

  12. Quantifying cerebral hypoxia by near-infrared spectroscopy tissue oximetry

    DEFF Research Database (Denmark)

    Rasmussen, Martin B.; Eriksen, Vibeke R.; Andresen, Bjørn

    2017-01-01

    Tissue oxygenation estimated by near-infrared spectroscopy (NIRS) is a volume-weighted mean of the arterial and venous hemoglobin oxygenation. In vivo validation assumes a fixed arterial-to-venous volume-ratio (AV-ratio). Regulatory cerebro-vascular mechanisms may change the AV-ratio. We used...

  13. Texas Pulse Oximetry Project: A Multicenter Educational and Quality Improvement Project for Implementation of Critical Congenital Heart Disease Screening Using Pulse Oximetry.

    Science.gov (United States)

    Guillory, Charleta; Gong, Alice; Livingston, Judith; Creel, Liza; Ocampo, Elena; McKee-Garrett, Tiffany

    2017-07-01

    Objective  Critical congenital heart disease (CCHD) is a leading cause of death in infants. Newborn screening (NBS) by pulse oximetry allows early identification of CCHD in asymptomatic newborns. To improve readiness of hospital neonatal birthing facilities for mandatory screening in Texas, an educational and quality improvement (QI) project was piloted to identify an implementation strategy for CCHD NBS in a range of birthing hospitals. Study Design  Thirteen Texas hospitals implemented standardized CCHD screening by pulse oximetry. An educational program was devised and a tool kit was created to facilitate education and implementation. Newborn nursery nurses' knowledge was assessed using a pre- and posttest instrument. Results  The nurses' knowledge assessment improved from 71 to 92.5% ( p  educational program, including a tool kit, QI processes, and standardized pulse oximetry CCHD NBS, is applicable for a range of hospital birthing facilities and may facilitate wide-scale implementation, thereby improving newborn health. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Respiratory Outcomes of the Surfactant Positive Pressure and Oximetry Randomized Trial

    Science.gov (United States)

    Stevens, Timothy P.; Finer, Neil N.; Carlo, Waldemar A.; Szilagyi, Peter G.; Phelps, Dale L.; Walsh, Michele C.; Gantz, Marie G.; Laptook, Abbot R.; Yoder, Bradley A.; Faix, Roger G.; Newman, Jamie E.; Das, Abhik; Do, Barbara T.; Schibler, Kurt; Rich, Wade; Newman, Nancy S.; Ehrenkranz, Richard A.; Peralta-Carcelen, Myriam; Vohr, Betty R.; Wilson-Costello, Deanne E.; Yolton, Kimberly; Heyne, Roy J.; Evans, Patricia W.; Vaucher, Yvonne E.; Adams-Chapman, Ira; McGowan, Elisabeth C.; Bodnar, Anna; Pappas, Athina; Hintz, Susan R.; Acarregui, Michael J.; Fuller, Janell; Goldstein, Ricki F.; Bauer, Charles R.; O’Shea, T. Michael; Myers, Gary J.; Higgins, Rosemary D.

    2014-01-01

    Objective To explore the early childhood pulmonary outcomes of infants who participated in the NICHD SUPPORT Trial, using a factorial design that randomized extremely preterm infants to lower vs. higher oxygen saturation targets and delivery room CPAP vs. intubation/surfactant, found no significant difference in the primary composite outcome of death or BPD. Study design The Breathing Outcomes Study, a prospective secondary to SUPPORT, assessed respiratory morbidity at 6 month intervals from hospital discharge to 18–22 months corrected age (CA). Two pre-specified primary outcomes, wheezing more than twice per week during the worst 2 week period and cough longer than 3 days without a cold were compared between each randomized intervention. Results One or more interviews were completed for 918 of 922 eligible infants. The incidence of wheezing and cough were 47.9% and 31.0%, respectively, and did not differ between study arms of either randomized intervention. Infants randomized to lower vs. higher oxygen saturation targets had similar risks of death or respiratory morbidities (except for croup, treatment with oxygen or diuretics at home). Infants randomized to CPAP vs. intubation/surfactant had fewer episodes of wheezing without a cold (28.9% vs. 36.5%, pCPAP rather than intubation/surfactant is associated with less respiratory morbidity by 18–22 months CA. Longitudinal assessment of pulmonary morbidity is necessary to fully evaluate the potential benefits of respiratory interventions for neonates. PMID:24725582

  15. Pulse oximetry and supplemental oxygen during gastrointestinal endoscopy: a critical review

    DEFF Research Database (Denmark)

    Holm, C; Rosenberg, J

    1996-01-01

    A high proportion of the mortality and morbidity associated with endoscopic procedures may be of cardiopulmonary origin. For this reason, the appropriate degree of monitoring and prophylactic measures to be used in the sedated patient undergoing endoscopy has become a topic of discussion during r...

  16. Gluon saturation in a saturated environment

    International Nuclear Information System (INIS)

    Kopeliovich, B. Z.; Potashnikova, I. K.; Schmidt, Ivan

    2011-01-01

    A bootstrap equation for self-quenched gluon shadowing leads to a reduced magnitude of broadening for partons propagating through a nucleus. Saturation of small-x gluons in a nucleus, which has the form of transverse momentum broadening of projectile gluons in pA collisions in the nuclear rest frame, leads to a modification of the parton distribution functions in the beam compared with pp collisions. In nucleus-nucleus collisions all participating nucleons acquire enhanced gluon density at small x, which boosts further the saturation scale. Solution of the reciprocity equations for central collisions of two heavy nuclei demonstrate a significant, up to several times, enhancement of Q sA 2 , in AA compared with pA collisions.

  17. Feasibility of pulse oximetry for assessment of infants born in community based midwifery care

    NARCIS (Netherlands)

    Smit, M.; Ganzeboom, A.; Dawson, J.A.; Walther, F.J.; Bustraan, J.; van Roosmalen, Jos; te Pas, A.B.

    2014-01-01

    To evaluate the feasibility of using pulse oximetry (PO) for evaluating infants born in community-based midwifery care. Design: a prospective, observational study of infants born after midwifery supervised (home) births. Setting: 27 midwives from seven practices providing primary care in (home)

  18. Prognostic value of nocturnal pulse oximetry in patients with heart failure.

    Science.gov (United States)

    Rivera-López, Ricardo; Jordán-Martínez, Laura; López-Fernández, Silvia; Rivera-Fernandez, Ricardo; Tercedor, Luis; Sáez-Roca, Germán

    2018-05-23

    To analyze the prognostic value of nocturnal hypoxemia measured with portable nocturnal pulse-oximetry in patients hospitalized due to heart failure and its relation to mortality and hospital readmission. We included 38 patients who were admitted consecutively to our unit with the diagnosis of decompensated heart failure. Pulse-oximetry was considered positive for hypoxemia when more than 10 desaturations per hour were recorded during sleep. Follow-up was performed for 30.3 (standard deviation [SD] 14.2) months, the main objective being a combined endpoint of all-cause mortality and hospital readmission due to heart failure. The average age was 70.7 (SD 10.7) years, 63.3% were males. Pulse-oximetry was considered positive for hypoxemia in 27 (71%) patients. Patients with positive pulse-oximetry had the most frequent endpoint (9.1% [1] vs. 61.5% [16], P = 0.003). After multivariate analysis, continuous nocturnal hypoxemia was related to the combined endpoint (HR = 8.37, 1.19-68.4, P = 0.03). Patients hospitalized for heart failure and nocturnal hypoxemia measured with portable pulse-oximeter have an increased risk of hospital readmission and death. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  19. High quantum efficiency annular backside silicon photodiodes for reflectance pulse oximetry in wearable wireless body sensors

    DEFF Research Database (Denmark)

    Duun, Sune Bro; Haahr, Rasmus Grønbek; Hansen, Ole

    2010-01-01

    The development of annular photodiodes for use in a reflectance pulse oximetry sensor is presented. Wearable and wireless body sensor systems for long-term monitoring require sensors that minimize power consumption. We have fabricated large area 2D ring-shaped silicon photodiodes optimized...

  20. Clinical use of cerebral oximetry in extremely preterm infants is feasible

    DEFF Research Database (Denmark)

    Hyttel-Sørensen, Simon; Austin, Topun; van Bel, Frank

    2013-01-01

    The research programme Safeguarding the Brains of our smallest Children (SafeBoosC) aims to test the benefits and harms of cerebral near-infrared spectroscopy (NIRS) oximetry in infants born before 28 weeks of gestation. In a phase II trial, infants will be randomised to visible cerebral NIRS...

  1. Evaluating the Use of Tissue Oximetry to Decrease Intensive Unit Monitoring for Free Flap Breast Reconstruction.

    Science.gov (United States)

    Ricci, Joseph A; Vargas, Christina R; Ho, Olivia A; Lin, Samuel J; Tobias, Adam M; Lee, Bernard T

    2017-07-01

    Postoperative free flap care has historically required intensive monitoring for 24 hours in an intensive care unit. Continuous monitoring with tissue oximetry has allowed earlier detection of vascular compromise, decreasing flap loss and improving salvage. This study aims to identify whether a fast-track postoperative paradigm can be safely used with tissue oximetry to decrease intensive monitoring and costs. All consecutive microsurgical breast reconstructions performed at a single institution were reviewed (2008-2014) and cases requiring return to the operating room were identified. Data evaluated included patient demographics, the take back time course, and complications of flap loss and salvage. A cost-benefit analysis was performed to analyse the utility of a postoperative intensive monitoring setting. There were 900 flaps performed and 32 required an unplanned return to the operating room. There were 16 flaps that required a reexploration within the first 24 hours; the standard length of intensive unit monitoring. After 4 hours, there were 7 flaps (44%) detected by tissue oximetry for reexploration. After 15 hours of intensive monitoring postoperatively, cost analysis revealed that the majority (15/16; 94%) of failing flaps had been identified and the cost of identifying each subsequent failing flap exceeded the cost of another hour of intensive monitoring. The postoperative paradigm for microsurgical flaps has historically required intensive unit monitoring. Using tissue oximetry, a fast-track pathway can reduce time spent in an intensive monitoring setting from 24 to 15 hours with significant cost savings and minimal risk of missing a failing free flap.

  2. An Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry

    DEFF Research Database (Denmark)

    Haahr, Rasmus Grønbek; Duun, Sune Bro; Toft, Mette H.

    2012-01-01

    photodiode to enable low power consumption by the light emitting components. The Electronic Patch has a disposable part of soft adhesive hydrocolloid polymer and a reusable part of hard polylaurinlactam. The disposable part contains the battery. The reusable part contains the reflectance pulse oximetry...

  3. Clinical use of cerebral oximetry in extremely preterm infants is feasible

    DEFF Research Database (Denmark)

    Hyttel-Sørensen, Simon; Austin, Topun; van Bel, Frank

    2013-01-01

    The research programme Safeguarding the Brains of our smallest Children (SafeBoosC) aims to test the benefits and harms of cerebral near-infrared spectroscopy (NIRS) oximetry in infants born before 28 weeks of gestation. In a phase II trial, infants will be randomised to visible cerebral NIRS oxi...

  4. Electron paramagnetic resonance and dynamic nuclear polarization of char suspensions: surface science and oximetry

    DEFF Research Database (Denmark)

    Clarkson, R B; Odintsov, B M; Ceroke, P J

    1998-01-01

    ; they can be calibrated and used for oximetry. Biological stability and low toxicity make chars good sensors for in vivo measurements. Scalar and dipolar interactions of water protons at the surfaces of chars may be utilized to produce dynamic nuclear polarization (DNP) of the nuclear spin population...

  5. Automatic NAA. Saturation activities

    International Nuclear Information System (INIS)

    Westphal, G.P.; Grass, F.; Kuhnert, M.

    2008-01-01

    A system for Automatic NAA is based on a list of specific saturation activities determined for one irradiation position at a given neutron flux and a single detector geometry. Originally compiled from measurements of standard reference materials, the list may be extended also by the calculation of saturation activities from k 0 and Q 0 factors, and f and α values of the irradiation position. A systematic improvement of the SRM approach is currently being performed by pseudo-cyclic activation analysis, to reduce counting errors. From these measurements, the list of saturation activities is recalculated in an automatic procedure. (author)

  6. Serum albumin--a non-saturable carrier

    DEFF Research Database (Denmark)

    Brodersen, R; Honoré, B; Larsen, F G

    1984-01-01

    The shape of binding isotherms for sixteen ligands to human serum albumin showed no signs of approaching saturation at high ligand concentrations. It is suggested that ligand binding to serum albumin is essentially different from saturable binding of substrates to enzymes, of oxygen to haemoglobi...

  7. Oxygen delivery and consumption during on-bypass cabg in htea and central analgesia

    Directory of Open Access Journals (Sweden)

    Віталій Олексійович Собокарь

    2015-04-01

    Full Text Available Objective. Despite some advantages, the use of high thoracic epidural anesthesia (HTEA during on-bypass cardiac surgery may be discouraged by fear of adverse hemodynamic effects and associated disturbances of oxygen delivery.Aim. To compare oxygen delivery and consumption during on-bypass coronary artery bypass grafting in settings of HTEA and central analgesia (CA.Methods. 132 patients were assigned into two groups – study group (n=85, where the surgery was performed under HTEA and control group (n=47 - where the surgery was carried out under CA. Using data of transesophageal cardiac ultrasound and blood oximetry blood oxygen delivery (DO2, oxygen consumption (VO2, oxygen extraction coefficient (CEO2 were calculated at four stages of the surgery: after induction, sternotomy, cardiopulmonary bypass and at the end of the surgery.Results. In the initial stages of the surgery DO2 and VO2 were reduced relative to reference values with a tendency to increase in the course of the operation and achievement of the normal or supernormal level (VO2, study group in the final stage. The decrease was due to moderate hypodynamic circulation and hemodilution. After sternotomy DO2 in the study group was higher than that of the control: 356 (279; 458 vs 317±89 ml·min-1·m-2, (р=0,021. After cardiopulmonary bypass oxygen saturation of venous blood (SatvO2, in the study group was 71 ± 9 % compared with 68 ± 10 % in the control group. At the end of the surgery SatvO2 in the study group was 71 (66; 75 vs 59 (53; 70 % in the control (р = 0,005 and oxygen tension of venous blood (РvО2 was correspondingly 39 ± 6 and 33 (30; 38 mm Hg (р = 0,027. Despite the decrease in DO2 and VO2, oxygen extraction indices - CEO2, pvO2, SatvO2, and remained within the reference range, except that of the control group at the end of the surgery. Furthermore, at no stage lactate rise or acid-base deviations was observed in the both groups.Conclusions. In patients operated

  8. Measurement of differences in pO2 in response to perfluorocarbon/carbogen in FSa and NFSa murine fibrosarcomas with low-frequency electron paramagnetic resonance oximetry.

    Science.gov (United States)

    Halpern, H J; Yu, C; Peric, M; Barth, E D; Karczmar, G S; River, J N; Grdina, D J; Teicher, B A

    1996-05-01

    We have used very low-frequency electron paramagnetic resonance (EPR) oximetry to measure the change in oxygen concentration (delta pO2) due to change in breathing atmosphere in FSa and NFSa fibrosarcomas implanted in the legs of C3H mice infused with perfluoro-octylbromine (PFOB). Measurements in each tumor were made before and after the administration of the high-density (47% v/v) perfluorocarbon PFOB, perflubron (Alliance Pharmaceutical Corporation, San Diego, CA). Measurements in each tumor were also made, after the administration of the PFOB, both before (PFOB/air) and after the administration of carbogen (95% O2 + 5% CO2, PFOB/carbogen). Large changes (delta p02) relative to PFOB/air oxygenation were seen with the administration of PFOB/carbogen. No significant difference in oxygen concentration was seen between air-breathing mice with and without PFOB. The mean delta pO2 for FSa tumors was 13 +/- 6 torr, while the mean for NFSa fibrosarcomas was 28 +/- 7 torr. There were such large intertumor differences that the trend toward a smaller change in the more hypoxic FSa tumors was not significant (P = 0.13). This paper describes a novel method of measuring differences in oxygenation in tumor tissues. The results of such measurements indicate large differences in pO2 response to different breathing atmospheres in PFOB-infused tumors of similar histology. The intertumor delta pO2 differences may correlate with differences in radiation response.

  9. The use of overnight pulse oximetry and phoniatrics parameters in the screening protocol of obstructive sleep apnea

    Directory of Open Access Journals (Sweden)

    Yassin Soliman Bahgat

    2012-10-01

    Conclusions: Polysomnography is the current golden standard test for diagnosis and evaluation of degree of OSA. Overnight pulse oximetry offers an inexpensive method of screening for and diagnosing OSAHS. Oximetry alone allowed confident recognition of moderate and severe cases of OSAHS. Acoustic analysis of snoring sounds and voice in patients with snoring and/or OSAHS is useful as a screening or supportive method with other investigations to diagnose the site of upper airway obstruction during sleep.

  10. The influence of external factors on the accuracy of non-invasive measuring of oxygen in blood

    Directory of Open Access Journals (Sweden)

    Y. M. Snizhko

    2016-05-01

    Full Text Available In this paper we investigated a pulse oximetry-based method for mobile devices. This method obtains bio-signals related to blood pulsation in transparent parts of body. The most widely accepted field for use of this method is hospital care. In these cases a pulse oximeter is the best solution for the monitoring of emergency patients. A promising field for pulse oximetry is physical exercise. It only requires simple clips such as ear-clips, finger-clips, headbands etc. However this method presents some difficulties: weak signal, noise ratio, motion artefacts, low perfusion. We used a MAX30100 Oximeter and Heart Rate Sensor integrated circuit to obtain signals of blood pulse waves from red and infrared light emission diodes (LED. This device measures the oxygen saturation of a person’s blood by placing an LED and a photodetector against the thin skin of a person’s body, such as a fingertip, wrist or earlobe. The MAX30100 is a 14-pin surface mount integrated circuit that contains sensors for measuring a person’s heart rate. It can also indirectly determine the oxygen saturation of a person’s blood. The MAX30100 provides a complete pulse oximetry and heart rate measurement solution for medical monitors and wearable fitness devices. As each LED emits light into a person’s finger, the integrated photodetector measures variations in light caused by changes in blood volume. An integrated 16-bit analog to digital converter (ADC with programmable sample rate converts the photodetector output to a digital value. The MAX30100 filters out ambient light that can interfere with an accurate reading. Data are read through a serial I2C interface to computer for further processing. The LED current can be programmed from 0 to 50 mA with proper supply voltage. The LED pulse width can be programmed from 200 µs to 1.6 ms to optimize measurement accuracy and power consumption based on use cases. The SpO2 algorithm is relatively insensitive to the wavelength

  11. A Novel β-Globin Chain Hemoglobin Variant, Hb Allentown [β137(H15)Val→Trp (GTG>TGG) HBB: c.412_413delinsTG, p.Val138Trp], Associated with Low Oxygen Saturation, Intermittent Aplastic Crises and Splenomegaly.

    Science.gov (United States)

    Collier, Anderson B; Coon, Lea M; Monteleone, Philip; Umaru, Samuel; Swanson, Kenneth C; Hoyer, James D; Oliveira, Jennifer L

    2016-01-01

    Hemoglobin (Hb) variants may be associated with low oxygen saturation and exacerbated episodes of anemia from common stressors such as viral infections. These attributes frequently cause increased clinical concern and unnecessary and expensive testing if not considered early in the evaluation of the patient. Some clinically significant Hb variants result in a normal Hb electrophoresis result, which can be method-dependent. Herein we describe a patient with low oxygen saturation and a history of hemolytic anemia who was subsequently found to carry a novel, unstable β-globin variant that we have named Hb Allentown [β137(H15)Val→Trp (GTG>TGG) HBB: c.412_413delinsTG, p.Val138Trp] for the place of identification of the variant. Hb Allentown is formed by a rare double nucleotide substitution within the same codon. Additionally, positive identification of rare Hb variants characterized by a single method is discouraged, as the Hb variant was misclassified as Hb S-South End or β6(A3)Glu→Val;β132(H10)Lys→Asn (HBB: c.[20A > T;399A > C]) by the initial laboratory.

  12. Maximal Oxygen Consumption is Reduced in Aquaporin-1 Knockout Mice

    Directory of Open Access Journals (Sweden)

    Samer Al-Samir

    2016-08-01

    Full Text Available We have measured maximal oxygen consumption (V’O2,max of mice lacking one or two of the established mouse red-cell CO2 channels AQP1, AQP9 and Rhag. We intended to study whether these proteins, by acting as channels for O2, determine O2 exchange in the lung and in the periphery. We found that V’O2,max as determined by the Helox technique is reduced by ~ 16%, when AQP1 is knocked out, but not when AQP9 or Rhag are lacking. This figure holds for animals respiring normoxic as well as hypoxic gas mixtures. To see whether the reduction of V’O2,max is due to impaired O2 uptake in the lung, we measured carotid arterial O2 saturation (SO2 by pulse oximetry. Neither under normoxic (inspiratory O2 21% nor under hypoxic conditions (11% O2 is there a difference in SO2 between AQP1null and WT mice, suggesting that AQP1 is not critical for O2 uptake in the lung. The fact that the % reduction of V’O2,max is identical in normoxia and hypoxia indicates moreover that the limitation of V’O2,max is not due to an O2 diffusion problem, neither in the lung nor in the periphery. Instead, it appears likely that AQP1null animals exhibit a reduced V’O2,max due to the reduced wall thickness and muscle mass of the left ventricles of their hearts, as reported previously. We conclude that very likely the properties of the hearts of AQP1 knockout mice cause a reduced maximal cardiac output and thus cause a reduced V’O2,max, which constitutes a new phenotype of these mice.

  13. Gluon Saturation and EIC

    Energy Technology Data Exchange (ETDEWEB)

    Sichtermann, Ernst

    2016-12-15

    The fundamental structure of nucleons and nuclear matter is described by the properties and dynamics of quarks and gluons in quantum chromodynamics. Electron-nucleon collisions are a powerful method to study this structure. As one increases the energy of the collisions, the interaction process probes regions of progressively higher gluon density. This density must eventually saturate. An high-energy polarized Electron-Ion Collider (EIC) has been proposed to observe and study the saturated gluon density regime. Selected measurements will be discussed, following a brief introduction.

  14. A unique case of pulmonary artery catheter bleeding from the oximetry connection port

    Directory of Open Access Journals (Sweden)

    Suman Rajagopalan

    2014-12-01

    Full Text Available Pulmonary artery catheter is an invasive monitor usually placed in high-risk cardiac surgical patients to optimize the cardiac functions. We present this case of blood oozing from the oximetry connection port of the pulmonary artery catheter that resulted in the inability to monitor continuous cardiac output requiring replacement of the catheter. The cause of this abnormal bleeding was later confirmed to be due to a manufacturing defect.

  15. Lung cancer symptoms and pulse oximetry in the prognostic assessment of patients with lung cancer

    Directory of Open Access Journals (Sweden)

    Harada Cecilia M

    2005-07-01

    Full Text Available Abstract Background Medical oncologists continue to use performance status as a proxy for quality of life (QOL measures, as completion of QOL instruments is perceived as time consuming, may measure aspects of QOL not affected by cancer therapy, and interpretation may be unclear. The pulse oximeter is widely used in clinical practice to predict cardiopulmonary morbidity after lung resection in cancer patients, but little is known on its role outside the surgical setting. We evaluated whether the Lung Cancer Symptom Scale and pulse oximetry may contribute to the evaluation of lung cancer patients who received standard anticancer therapy. Methods We enrolled forty-one consecutive, newly diagnosed, patients with locally advanced or metastatic lung cancer in this study. We developed a survival model with the variables gender, age, histology, clinical stage, Karnofsky performance status, wasting, LCSS symptom scores, average symptom burden index, and pulse oximetry (SpO2. Results Patient and observer-rated scores were correlated, except for the fatigue subscale. The median SpO2 was 95% (range: 86 to 98, was unrelated to symptom scores, and was weakly correlated with observer cough scores. In a multivariate survival model, SpO2 > 90% and patient scores on the LCSS appetite and fatigue subscales were independent predictors of survival. Conclusion LCSS fatigue and appetite rating, and pulse oximetry should be studied further as prognostic factors in lung cancer patients.

  16. High quantum efficiency annular backside silicon photodiodes for reflectance pulse oximetry in wearable wireless body sensors

    International Nuclear Information System (INIS)

    Duun, Sune; Haahr, Rasmus G; Hansen, Ole; Birkelund, Karen; Thomsen, Erik V

    2010-01-01

    The development of annular photodiodes for use in a reflectance pulse oximetry sensor is presented. Wearable and wireless body sensor systems for long-term monitoring require sensors that minimize power consumption. We have fabricated large area 2D ring-shaped silicon photodiodes optimized for minimizing the optical power needed in reflectance pulse oximetry. To simplify packaging, backside photodiodes are made which are compatible with assembly using surface mounting technology without pre-packaging. Quantum efficiencies up to 95% and area-specific noise equivalent powers down to 30 fW Hz -1/2 cm -1 are achieved. The photodiodes are incorporated into a wireless pulse oximetry sensor system embedded in an adhesive patch presented elsewhere as 'The Electronic Patch'. The annular photodiodes are fabricated using two masked diffusions of first boron and subsequently phosphor. The surface is passivated with a layer of silicon nitride also serving as an optical filter. As the final process, after metallization, a hole in the center of the photodiode is etched using deep reactive ion etch.

  17. Novel 1H NMR approach to quantitative tissue oximetry using hexamethyldisiloxane.

    Science.gov (United States)

    Kodibagkar, Vikram D; Cui, Weina; Merritt, Matthew E; Mason, Ralph P

    2006-04-01

    19F NMR spin-lattice relaxometry of hexafluorobenzene (HFB) has been shown to be a highly sensitive indicator of tumor oxygenation. In this study hexamethyldisiloxane (HMDSO) was identified as a proton NMR analog, and its potential as a probe for investigating dynamic changes in tissue oxygen tension (pO2) was evaluated. HMDSO has a single proton resonance (delta= -0.3 ppm) and the spin-lattice relaxation rate, Rl (= 1/T1) exhibits a linear dependence on pO2: R1 (s(-1)) = 0.1126 + 0.0013* pO2 (torr) at 37 degrees C. To demonstrate application in vivo, HMDSO was administered into healthy rat thigh muscle (100 microl) and tumors (50 microl). Local pO2 was determined by using pulse-burst saturation recovery (PBSR) 1H NMR spectroscopy to assess R1. Water and fat signals were effectively suppressed by frequency-selective excitation of the HMDSO resonance. Rat thigh muscle had a mean baseline pO2 of 35 +/- 11 torr, with a typical stability of +/-3 torr over 20 min, when the rats breathed air. Altering the inhaled gas to oxygen produced a significant increase in pO2 to 100-200 torr. In tumors, altering the inspired gas also produced significant (albeit generally smaller) changes. This new pO2 reporter molecule offers a potentially valuable new tool for investigating pO2 in vivo. (c) 2006 Wiley-Liss, Inc.

  18. Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.

    Science.gov (United States)

    Abay, T Y; Kyriacou, P A

    2018-06-01

    Photoplethysmography (PPG) is an optical technique that measures blood volume variations. The main application of dual-wavelength PPG is pulse oximetry, in which the arterial oxygen saturation (SpO[Formula: see text]) is calculated noninvasively. However, the PPG waveform contains other significant physiological information that can be used in conjunction to SpO[Formula: see text] for the assessment of oxygenation and blood volumes changes. This paper investigates the use of near infrared spectroscopy (NIRS) processing techniques for extracting relative concentration changes of oxygenated ([Formula: see text]HbO[Formula: see text]), reduced ([Formula: see text]HHb) and total haemoglobin ([Formula: see text]tHb) from dual-wavelength PPG signals during intermittent pressure-increasing vascular occlusions. A reflectance PPG sensor was attached on the left forearm of nineteen (n = 19) volunteers, along with a reference NIRS sensor positioned on the same forearm, above the left brachioradialis. The investigation protocol consisted of seven intermittent and pressure-increasing vascular occlusions. Relative changes in haemoglobin concentrations were obtained by applying the modified Beer-Lambert law to PPG signals, while oxygenation changes were estimated by the difference between red and infrared attenuations of DC PPGs (A[Formula: see text] = [Formula: see text]A[Formula: see text] - [Formula: see text]A[Formula: see text]) and by the conventional SpO[Formula: see text]. The [Formula: see text]HbO[Formula: see text], [Formula: see text]HHb, [Formula: see text]tHb from the PPG signals indicated significant changes in perfusion induced by either partial and complete occlusions (p < 0.05). The trends in the variables extracted from PPG showed good correlation with the same parameters measured by the reference NIRS monitor. Bland and Altman analysis of agreement between PPG and NIRS showed underestimation of the magnitude of changes by the PPG. A[Formula: see text

  19. The role of nocturnal oximetry in obstructive sleep apnoea-hypopnoea syndrome screening

    Directory of Open Access Journals (Sweden)

    Celestina Ventura

    2007-07-01

    Full Text Available Aim: The aim of our study was to evaluate the sensitivity and specificity of Nocturnal Oximetry (NO as a diagnostic screening tool for obstructive sleep apnoea hypopnoea syndrome (OSAHS, compared with polysomnography (PSG as the gold standard. Methodology: 63 patients with clinical suspicion of OSAHS and exclusion of respiratory disease underwent PSG and NO. We then determined NO sensitivity, specificity, positive (PPV and negative predictive values (NPV. Results: OSAHS was diagnosed in 47 patients with a mean age of 54 years. In the evaluation of the percentage of Total Sleep Time (TST with oxygen desaturation below 90%, we found significant differences between patients with OSAHS (25.4 ± 29.7% and without OSAHS (1 ± 1.5%, p<0,001. We used two cutoff points to evaluate sensitivity, specificity, positive (PPV and negative predictive values (NPV, based on the severity of O2 desaturation (StO2<90%. Using the first cutoff point we diagnosed with NO as positive all the patients with TST desaturation values ≥1% of the TST. Under these circumstances we found a sensitivity of 76.6%, a specificity of 75%, a PPV of 90% and an NPV value of 52.2% for our screening test (NO. Using the second cutoff point, we diagnosed with NO as positive all the patients with TST desaturation values ≥5% of the TST. With this method we found a sensitivity of 65.9%, a specificity of 100%, a PPV of 100% and an NPV of 50%. Conclusion: NO is a useful screening test for the diagnosis of OSAHS in patients without respiratory disease. Resumo: Objectivo: Foi objectivo deste estudo determinar a sensibilidade e a especificidade da oximetria nocturna (ON como método de screening diagnóstico para a síndroma de apneia-hipopneia obstrutiva do sono (SAHOS, utilizando como método de referência a polissonografia (PSG. Metodologia: Foram incluídos 63 doentes com suspeita clínica de SAHOS e exclusão de doença respiratória, sendo

  20. Evaluación de parámetros fisiológicos en función de la saturación de oxigeno muscular en mujeres con sobrepeso y obesidad. [Evaluation physiological parameters depending on muscle oxygen saturation in overweight and obesity].

    Directory of Open Access Journals (Sweden)

    Aldo Alfonso Vasquez-Bonilla

    2017-01-01

    Full Text Available El objetivo de este estudio fue evaluar parámetros fisiológicos para comparar y correlacionar en función de la saturación de oxigeno muscular y hemoglobina total medida con espectroscopia de infrarrojo cercano no invasivo. La muestra (n=17 mujeres se dividieron en 2 grupos: sobrepeso/obesidad y normopeso, se valoró la composición corporal, parámetros fisiológicos, saturación de oxigeno muscular e indicie de esfuerzo percibido durante la prueba de esfuerzo incremental máxima en un cicloergometro en base a cuatro zonas metabólicas establecidas: fatmax, umbral aeróbico, umbral anaeróbico y zona de consumo máximo de oxígeno. Los resultados se analizaron utilizando el método estadístico Anova de un factor y la correlación de pearsón. Los resultados encontrados en el grupo normopeso la saturación de oxigeno muscular tiene correlación positiva alta con el vo2max durante la zona fatmax y umbral aeróbico (r=0,72- p=0,04 (r=0,77 – p=0,02, la frecuencia cardíaca de entrenamiento (r= -0,87 – p=0,01 tiene correlación negativa muy alta en la zona umbral anaeróbico, en el grupo sobrepeso obesidad no se encontró ninguna correlación. En conclusión las mujeres con normopeso la saturación de oxigeno muscular medida con espectroscopia de infrarrojo cercano no invasivo puede ser un buen parámetro fisiológico para programar ejercicio en la zonas fatmax, umbral aeróbico y umbral anaeróbico, pero en las mujeres con sobrepeso y obesidad se necesitan más estudios. Abstract The objective of this study was to compare physiological parameters and correlate function of muscle oxygen saturation and total hemoglobin measured with near-infrared spectroscopy noninvasive. The sample (n = 17 women were divided into 2 groups: overweight / obese and normal weight, was measured body composition, physiological parameters, saturation of muscle oxygen and index of perceived exertion during testing maximum incremental exercise on a cycle ergometer

  1. [Cerebral oximetry in pulmonary thromboendarterectomy with circulatory arrest].

    Science.gov (United States)

    Catalán Escudero, P; González Román, A; Serra Ruiz, C N; Barbero Mielgo, M; García Fernández, J

    2014-02-01

    Pulmonary thromboendarterectomy is an uncommon procedure and should be performed with circulatory arrest. One of the major concerns is the postoperative central neurological injuries. Perioperative brain oxygen monitoring is advisable in this surgical procedure for the early detection of brain hypoperfusion episodes and their intensity as well as any other postoperative episodes that can deteriorate the neurological outcome. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  2. Oxygen Concentration Inside a Functioning Photosynthetic Cell

    OpenAIRE

    Kihara, Shigeharu; Hartzler, Daniel A.; Savikhin, Sergei

    2014-01-01

    The excess oxygen concentration in the photosynthetic membranes of functioning oxygenic photosynthetic cells was estimated using classical diffusion theory combined with experimental data on oxygen production rates of cyanobacterial cells. The excess oxygen concentration within the plesiomorphic cyanobacterium Gloeobactor violaceus is only 0.025 μM, or four orders of magnitude lower than the oxygen concentration in air-saturated water. Such a low concentration suggests that the first oxygenic...

  3. Cerebral near infrared spectroscopy oximetry in extremely preterm infants

    DEFF Research Database (Denmark)

    Hyttel-Sørensen, Simon; Pellicer, Adelina; Alderliesten, Thomas

    2015-01-01

    blinded to group allocation. RESULTS: The 86 infants randomised to the NIRS group had a median burden of hypoxia and hyperoxia of 36.1%hours (interquartile range 9.2-79.5%hours) compared with 81.3 (38.5-181.3) %hours in the control group, a reduction of 58% (95% confidence interval 35% to 73%, P....001). In the experimental group the median burden of hypoxia was 16.6 (interquartile range 5.4-68.1) %hours, compared with 53.6 (17.4-171.3) %hours in the control group (P=0.0012). The median burden of hyperoxia was similar between the groups: 1.2 (interquartile range 0.3-9.6) %hours in the experimental group compared...... oxygenation using NIRS in combination with a dedicated treatment guideline during the first 72 hours of life (experimental) compared with blinded NIRS oxygenation monitoring with standard care (control). MAIN OUTCOME MEASURES: The primary outcome measure was the time spent outside the target range of 55...

  4. Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI).

    Science.gov (United States)

    Harris, Robert J; Yao, Jingwen; Chakhoyan, Ararat; Raymond, Catalina; Leu, Kevin; Liau, Linda M; Nghiemphu, Phioanh L; Lai, Albert; Salamon, Noriko; Pope, Whitney B; Cloughesy, Timothy F; Ellingson, Benjamin M

    2018-04-06

    To introduce a new pH-sensitive and oxygen-sensitive MRI technique using amine proton CEST echo spin-and-gradient echo (SAGE) EPI (CEST-SAGE-EPI). pH-weighting was obtained using CEST estimations of magnetization transfer ratio asymmetry (MTR asym ) at 3 ppm, and oxygen-weighting was obtained using R2' measurements. Glutamine concentration, pH, and relaxation rates were varied in phantoms to validate simulations and estimate relaxation rates. The values of MTR asym and R2' in normal-appearing white matter, T 2 hyperintensity, contrast enhancement, and macroscopic necrosis were measured in 47 gliomas. Simulation and phantom results confirmed an increase in MTR asym with decreasing pH. The CEST-SAGE-EPI estimates of R 2 , R2*, and R2' varied linearly with gadolinium diethylenetriamine penta-acetic acid concentration (R 2  = 6.2 mM -1 ·sec -1 and R2* = 6.9 mM -1 ·sec -1 ). The CEST-SAGE-EPI and Carr-Purcell-Meiboom-Gill estimates of R 2 (R 2  = 0.9943) and multi-echo gradient-echo estimates of R2* (R 2  = 0.9727) were highly correlated. T 2 lesions had lower R2' and higher MTR asym compared with normal-appearing white matter, suggesting lower hypoxia and high acidity, whereas contrast-enhancement tumor regions had elevated R2' and MTR asym , indicating high hypoxia and acidity. The CEST-SAGE-EPI technique provides simultaneous pH-sensitive and oxygen-sensitive image contrasts for evaluation of the brain tumor microenvironment. Advantages include fast whole-brain acquisition, in-line B 0 correction, and simultaneous estimation of CEST effects, R 2 , R2*, and R2' at 3 T. © 2018 International Society for Magnetic Resonance in Medicine.

  5. Retinal Oximetry and Vessel Diameter Measurements With a Commercially Available Scanning Laser Ophthalmoscope in Diabetic Retinopathy.

    Science.gov (United States)

    Blair, Norman P; Wanek, Justin; Felder, Anthony E; Joslin, Charlotte E; Kresovich, Jacob K; Lim, Jennifer I; Chau, Felix Y; Leiderman, Yannek; Shahidi, Mahnaz

    2017-10-01

    To test the hypothesis that retinal vascular diameter and hemoglobin oxygen saturation alterations, according to stages of diabetic retinopathy (DR), are discernible with a commercially available scanning laser ophthalmoscope (SLO). One hundred eighty-one subjects with no diabetes (No DM), diabetes with no DR (No DR), nonproliferative DR (NPDR), or proliferative DR (PDR, all had photocoagulation) underwent imaging with an SLO with dual lasers (532 nm and 633 nm). Customized image analysis software determined the diameters of retinal arteries and veins (DA and DV) and central retinal artery and vein equivalents (CRAE and CRVE). Oxygen saturations of hemoglobin in arteries and veins (SO2A and SO2V) were estimated from optical densities of vessels on images at the two wavelengths. Statistical models were generated by adjusting for effects of sex, race, age, eye, and fundus pigmentation. DA, CRAE, and CRVE were reduced in PDR compared to No DM (P ≤ 0.03). DV and CRVE were similar between No DM and No DR, but they were higher in NPDR than No DR (P ≤ 0.01). Effect of stage of disease on SO2A differed by race, being increased relative to No DM in NPDR and PDR in Hispanic participants only (P ≤ 0.02). Relative to No DM, SO2V was increased in NPDR and PDR (P ≤ 0.05). Alterations in retinal vascular diameters and SO2 by diabetic retinopathy stage can be detected with a widely available SLO, and covariates such as race can influence the results.

  6. Transcutaneous oximetry measurements of the leg: comparing different measuring equipment and establishing values in healthy young adults.

    Science.gov (United States)

    Trinks, Tobias P; Blake, Denise F; Young, Derelle A; Thistlethwaite, Ken; Vangaveti, Venkat N

    2017-06-01

    Transcutaneous oximetry measurement (TCOM) is a non-invasive method of determining oxygen tension at the skin level using heated electrodes. To compare TCOM values generated by different machines and to establish lower limb TCOM values in a cohort of healthy individuals younger than 40 years of age. Sixteen healthy, non-smoking volunteers aged 18 to 39 years were recruited. TCOM was obtained at six locations on the lower leg and foot using three different Radiometer machines. Measurements were taken with subjects lying supine, breathing air. Except for one sensor site, there were no statistical differences in measurements obtained by the different TCOM machines. There was no statistical difference in measurements comparing left and right legs. Room air TCOM values for the different lower leg sites were (mean (SD) in mmHg): lateral leg 61.5 (9.2); lateral ankle 61.1 (9.7); medial ankle 59.1 (10.8); foot, first and second toe 63.4 (10.6); foot, fifth toe 59.9 (13.2) and plantar foot 74.1 (8.8). The overall mean TCOM value for the lower limb was 61 (10.8; 95% confidence intervals 60.05-62.0) mmHg. Lower-leg TCOM measurements using different Radiometer TCOM machines were comparable. Hypoxia has been defined as lower-leg TCOM values of less than 40 mmHg in non-diabetic patients and this is supported by our measurements. The majority (96.9%) of the lower leg TCOM values in healthy young adults are above the hypoxic threshold.

  7. Knowledge of oxygen administration, aerosol medicine, and chest physiotherapy among pediatric healthcare workers in Italy.

    Science.gov (United States)

    Esposito, Susanna; Brivio, Anna; Tagliabue, Claudia; Galeone, Carlotta; Tagliaferri, Laura; Serra, Domenico; Foà, Michela; Patria, Maria Francesca; Marchisio, Paola; Principi, Nicola

    2011-06-01

    Oxygen administration, aerosol devices and drugs, or the use of chest physiotherapy are common practices in pediatrics; however, little is known about the knowledge of pediatric healthcare workers concerning the right utilization of these tools. The aim of this study was to fill this gap as a preliminary step in the implementation of appropriate educational programs. This cross-sectional survey of a nationally representative sample of Italian pediatricians and nurses was carried out between September 1 and October 8, 2008. A self-administered, anonymous questionnaire concerning the approach to respiratory disease in infants and children was distributed to all of the participants at the Annual Congress of the Italian Society of Pediatrics, together with a stamped envelope addressed to the trained study researchers. Of the 900 distributed questionnaires, 76.7% were completed and returned by 606 physicians (199 primary care pediatricians, 245 hospital pediatricians, and 162 pediatric residents) and 84 pediatric nurses. The vast majority of the respondents did not know the percentage of hemoglobin saturation indicating hypoxemia that requires oxygen administration. Most of the nurses admitted to overusing mucolytics and inhalatory corticosteroids, did not know the role of ipratropium bromide, were unable to indicate the first-line drug for respiratory distress, and did not know the correct dose of salbutamol. Only a minority of the respondents were able to specify the indications for chest physiotherapy. The nurses gave the fewest correct answers regardless of their age, gender, work setting, or the frequency with which they cared for children with respiratory distress in a year cared. The knowledge of primary care pediatricians, hospital pediatricians, and pediatric nurses in Italy concerning the use of pulse oximetry, aerosol devices and drugs, and chest physiotherapy is far from satisfactory and should be improved. Educational programs are therefore required for

  8. Retinal Vascular and Oxygen Temporal Dynamic Responses to Light Flicker in Humans.

    Science.gov (United States)

    Felder, Anthony E; Wanek, Justin; Blair, Norman P; Shahidi, Mahnaz

    2017-11-01

    To mathematically model the temporal dynamic responses of retinal vessel diameter (D), oxygen saturation (SO2), and inner retinal oxygen extraction fraction (OEF) to light flicker and to describe their responses to its cessation in humans. In 16 healthy subjects (age: 60 ± 12 years), retinal oximetry was performed before, during, and after light flicker stimulation. At each time point, five metrics were measured: retinal arterial and venous D (DA, DV) and SO2 (SO2A, SO2V), and OEF. Intra- and intersubject variability of metrics was assessed by coefficient of variation of measurements before flicker within and among subjects, respectively. Metrics during flicker were modeled by exponential functions to determine the flicker-induced steady state metric values and the time constants of changes. Metrics after the cessation of flicker were compared to those before flicker. Intra- and intersubject variability for all metrics were less than 6% and 16%, respectively. At the flicker-induced steady state, DA and DV increased by 5%, SO2V increased by 7%, and OEF decreased by 13%. The time constants of DA and DV (14, 15 seconds) were twofold smaller than those of SO2V and OEF (39, 34 seconds). Within 26 seconds after the cessation of flicker, all metrics were not significantly different from before flicker values (P ≥ 0.07). Mathematical modeling revealed considerable differences in the time courses of changes among metrics during flicker, indicating flicker duration should be considered separately for each metric. Future application of this method may be useful to elucidate alterations in temporal dynamic responses to light flicker due to retinal diseases.

  9. Singlet oxygen quenching by oxygen in tetraphenyl-porphyrin solutions

    International Nuclear Information System (INIS)

    Dedic, Roman; Korinek, Miloslav; Molnar, Alexander; Svoboda, Antonin; Hala, Jan

    2006-01-01

    Time-resolved measurement of singlet oxygen infrared phosphorescence is a powerful tool for determination of quantum yields and kinetics of its photosensitization. This technique was employed to investigate in detail the previously observed effect of singlet oxygen quenching by oxygen. The question whether the singlet oxygen is quenched by oxygen in ground or in excited state was addressed by study of two complementary dependencies of singlet oxygen lifetimes: on dissolved oxygen concentration and on excitation intensity. Oxygen concentration dependence study of meso-tetra(4-sulphonato)phenylporphyrin (TPPS 4 ) phosphorescence kinetics showed linearity of the dependence of TPPS 4 triplet state rate-constant. Corresponding bimolecular quenching constant of (1.5±0.1)x10 9 l/mol s was obtained. On the other hand, rate constants of singlet oxygen depopulation exhibit nonlinear dependence on oxygen concentration. Comparison of zero oxygen concentration-extrapolated value of singlet oxygen lifetime of (6.5±0.4) μs to (3.7±0.1) μs observed under air-saturated conditions indicates importance of the effect of quenching of singlet oxygen by oxygen. Upward-sloping dependencies of singlet oxygen depopulation rate-constant on excitation intensity evidence that singlet oxygen is predominantly quenched by oxygen in excited singlet state

  10. Early Detection with Pulse Oximetry of Hypoxemic Neonatal Conditions. Development of the IX Clinical Consensus Statement of the Ibero-American Society of Neonatology (SIBEN

    Directory of Open Access Journals (Sweden)

    Augusto Sola

    2018-03-01

    Full Text Available This article reviews the development of the Ninth Clinical Consensus Statement by SIBEN (the Ibero-American of Neonatology on “Early Detection with Pulse Oximetry (SpO2 of Hypoxemic Neonatal Conditions”. It describes the process of the consensus, and the conclusions and recommendations for screening newborns with pulse oximetry.

  11. Melodic algorithms for pulse oximetry to allow audible discrimination of abnormal systolic blood pressures.

    Science.gov (United States)

    Chima, Ranjit S; Ortega, Rafael; Connor, Christopher W

    2014-12-01

    An anesthesiologist must remain vigilant of the patient's clinical status, incorporating many independent physiological measurements. Oxygen saturation and heart rate are represented by continuous audible tones generated by the pulse oximeter, a mandated monitoring device. Other important clinical parameters--notably blood pressure--lack any audible representation beyond arbitrarily-configured threshold alarms. Attempts to introduce further continuous audible tones have apparently foundered; the complexity and interaction of these tones have exceeded the ability of clinicians to interpret them. Instead, we manipulate the tonal and rhythmic structure of the accepted pulse oximeter tone pattern melodically. Three melodic algorithms were developed to apply tonal and rhythmic variations to the continuous pulse oximeter tone, dependent on the systolic blood pressure. The algorithms distort the original audible pattern minimally, to facilitate comprehension of both the underlying pattern and the applied variations. A panel of anesthesia practitioners (attending anesthesiologists, residents and nurse anesthetists) assessed these algorithms in characterizing perturbations in cardiopulmonary status. Twelve scenarios, incorporating combinations of oxygen desaturation, bradycardia, tachycardia, hypotension and hypertension, were tested. A rhythmic variation in which additional auditory information was conveyed only at halftime intervals, with every other "beat" of the pulse oximeter, was strongly favored. The respondents also strongly favored the use of musical chords over single tones. Given three algorithms of tones embedded in the pulse oximeter signal, anesthesiologists preferred a melodic tone to signal a significant change in blood pressure.

  12. Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.

    Science.gov (United States)

    Barker, Steven J; Curry, Jeremy; Redford, Daniel; Morgan, Scott

    2006-11-01

    A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. Ten volunteers breathed 500 ppm carbon monoxide until their carboxyhemoglobin levels reached 15%, and 10 different volunteers received intravenous sodium nitrite, 300 mg, to induce methemoglobin. All were instrumented with arterial cannulas and six Masimo Rad-57 (Masimo Inc., Irvine, CA) pulse oximeter sensors. Arterial blood was analyzed by three laboratory CO-oximeters, and the resulting carboxyhemoglobin and methemoglobin measurements were compared with the corresponding pulse oximeter readings. The Rad-57 measured carboxyhemoglobin with an uncertainty of +/-2% within the range of 0-15%, and it measured methemoglobin with an uncertainty of 0.5% within the range of 0-12%. The Masimo Rad-57 is the first commercially available pulse oximeter that can measure methemoglobin and carboxyhemoglobin, and it therefore represents an expansion of our oxygenation monitoring capability.

  13. Clinical evaluation of the effects of signal integrity and saturation on data availability and accuracy of Masimo SE and Nellcor N-395 oximeters in children.

    Science.gov (United States)

    Robertson, Frederick A; Hoffman, George M

    2004-03-01

    Pulse oximetry manufacturers have introduced technologies that claim improved detection of hypoxemic events. Because improvements in signal processing and data rejection algorithms may differentially affect data reporting, we compared the data reporting and signal heuristic performance and agreement among the Nellcor N-395, Masimo SET, and GE Solar 8000 oximeters under a spectrum of conditions of signal integrity and arterial oxygen saturations. A blinded side-by-side comparison of technologies was performed in 27 patients, and data were analyzed for time of data availability, measures of agreement and signal heuristics, and warnings stratified by signal integrity and SpO(2). The Solar 8000 had less total data dropout than either of the new technologies. Masimo's LoSIQ (signal quality) heuristic rejected less data than Nellcor's MOT/PS (motion/pulse search) flag. When no signal heuristic was displayed, there was little difference in precision and bias between the two newer technologies; however, agreement between devices deteriorated in the presence of SIQ, MOT, or hypoxemia. Both newer devices flagged questionable data, but their use of different rejection algorithms resulted in different probabilities of presenting data. Therefore, with poor SIQ or during hypoxemia, the Nellcor N-395 and Masimo oximeters are not clinically equivalent to each other or to the older Solar 8000 oximeter. We compared new pulse oximeters from Nellcor and Masimo and found that, with good signal conditions, both new devices performed similarly to older technology. Overall, Masimo reported less data as questionable than Nellcor. With poor signal conditions or during hypoxemia, the new devices are not clinically equivalent to each other or to the older technology.

  14. Temporal variation in the response of tumors to hyperoxia with breathing carbogen and oxygen

    Science.gov (United States)

    Hou, Hua-gang; Khan, Nadeem; Du, Gai-xin; Hodge, Sassan; Swartz, Harold M.

    2016-01-01

    The effect of hyperoxygenation with carbogen (95% O2 + 5% CO2) and 100% oxygen inhalation on partial pressure of oxygen (pO2) of radiation-induced fibrosarcoma (RIF-1) tumor was investigated. RIF-1 tumors were innoculated in C3H mice, and aggregates of oximetry probe, lithium phthalocyanine (LiPc), was implanted in each tumor. A baseline tumor pO2 was measured by electron paramagnetic resonance (EPR) oximetry for 20 minutes in anesthetized mice breathing 30% O2 and then the gas was switched to carbogen or 100 % oxygen for 60 minutes. These experiments were repeated for 10 days. RIF-1 tumors were hypoxic with a baseline tissue pO2 of 6.2–8.3 mmHg in mice breathing 30% O2. Carbogen and 100% oxygen significantly increased tumor pO2 on days 1 to 5, with a maximal increase at approximately 32–45 minutes on each day. However, the extent of increase in pO2 from the baseline declined significantly on day 5 and day 10. The results provide quantitative information on the effect of hyperoxic gas inhalation on tumor pO2 over the course of 10 days. EPR oximetry can be effectively used to repeatedly monitor tumor pO2 and test hyperoxic methods for potential clinical applications. PMID:27867481

  15. Temporal variation in the response of tumors to hyperoxia with breathing carbogen and oxygen

    Directory of Open Access Journals (Sweden)

    Hua-gang Hou

    2016-01-01

    Full Text Available The effect of hyperoxygenation with carbogen (95% O 2 + 5% CO 2 and 100% oxygen inhalation on partial pressure of oxygen (pO 2 of radiation-induced fibrosarcoma (RIF-1 tumor was investigated. RIF-1 tumors were innoculated in C3H mice, and aggregates of oximetry probe, lithium phthalocyanine (LiPc, was implanted in each tumor. A baseline tumor pO 2 was measured by electron paramagnetic resonance (EPR oximetry for 20 minutes in anesthetized mice breathing 30% O 2 and then the gas was switched to carbogen or 100 % oxygen for 60 minutes. These experiments were repeated for 10 days. RIF-1 tumors were hypoxic with a baseline tissue pO 2 of 6.2-8.3 mmHg in mice breathing 30% O 2 . Carbogen and 100% oxygen significantly increased tumor pO 2 on days 1 to 5, with a maximal increase at approximately 32-45 minutes on each day. However, the extent of increase in pO 2 from the baseline declined significantly on day 5 and day 10. The results provide quantitative information on the effect of hyperoxic gas inhalation on tumor pO 2 over the course of 10 days. EPR oximetry can be effectively used to repeatedly monitor tumor pO 2 and test hyperoxic methods for potential clinical applications.

  16. The OXIMAPA Study: Hypertension Control by ABPM and Association with Sleep Apnea Syndrome by Pulse Oximetry.

    Science.gov (United States)

    Maricoto, Tiago; Silva, Eurico Alves Rodrigues; Damião, Pedro; Bastos, José Mesquita

    2017-02-27

    Ambulatory blood pressure monitoring by automatic device is the best blood pressure evaluation method and sleep apnea syndrome is the leading cause of poor control. Oximetry allows screening these individuals but its usefulness has been poorly explored in Primary Health Care. The aim was to evaluate the blood pressure control at the office and with ambulatory blood pressure monitoring by automatic device and to relate it to sleep apnea syndrome. We selected a sample of 50 participants, representative of 3036 hypertensive patients. The variables were: blood pressure value at the office and blood pressure with ambulatory blood pressure monitoring by automatic device; presence of criteria of sleep apnea syndrome in oximetry. The prevalence of uncontrolled blood pressure was 56% on office evaluation and 68% on ambulatory blood pressure monitoring by automatic device. It was found: 36% of daytime hypertension, 52% nocturnal hypertension, 40% non-dipper profile, 16% of white coat hypertension and 28% masked hypertension. The prevalence of sleep apnea syndrome was 16%. Blood pressure in ambulatory blood pressure monitoring by automatic device and blood pressure in office showed no statistically significant association (p = 0.761). We found a statistically significant association between sleep apnea syndrome and daytime hypertension (p = 0.019) and non-dipper profile (p = 0.005). Ambulatory blood pressure monitoring by automatic device detected more 12% of uncontrolled hypertension than office blood pressure. Sleep apnea syndrome is strongly associated with uncontrolled hypertension and oximetry may be a good screening method, but should be studied further.

  17. Factors Determining the Oxygen Permeability of Biological Membranes: Oxygen Transport Across Eye Lens Fiber-Cell Plasma Membranes.

    Science.gov (United States)

    Subczynski, Witold Karol; Widomska, Justyna; Mainali, Laxman

    2017-01-01

    Electron paramagnetic resonance (EPR) spin-label oximetry allows the oxygen permeability coefficient to be evaluated across homogeneous lipid bilayer membranes and, in some cases, across coexisting membrane domains without their physical separation. The most pronounced effect on oxygen permeability is observed for cholesterol, which additionally induces the formation of membrane domains. In intact biological membranes, integral proteins induce the formation of boundary and trapped lipid domains with a low oxygen permeability. The effective oxygen permeability coefficient across the intact biological membrane is affected not only by the oxygen permeability coefficients evaluated for each lipid domain but also by the surface area occupied by these domains in the membrane. All these factors observed in fiber cell plasma membranes of clear human eye lenses are reviewed here.

  18. Neonatal screening for life-threatening conditions persistent – pulmonary hypertension in newborns and critical congenital heart disease – by the method of pulse oximetry

    Directory of Open Access Journals (Sweden)

    D. I. Sadykova

    2017-01-01

    Full Text Available Research objective: to assess the diagnostic significance of the pulse oximetry performed by the newborn for the 3rd hour of life to identify critical conditions and to justify the expediency of further introduction of this technology in the work of obstetric institutions.Results. In 5 maternity hospitals of the Republic of Tatarstan, from April 2016 to February 2017, 8358 88.4% of newborns were pulsometrically screened. Positive results were obtained in 95 (1.14% patients. Because of screening, 13 newborns were diagnosed with congenital heart defects, not diagnosed in utero, in the first hours of life, five of them were critical. All newborns with critical congenital heart defects were successfully operated. Besides, 20 patients had persistent pulmonary hypertension, 30 had intrauterine pneumonia.Conclusions. The measurement of saturation at the 3rd hour of life of a newborn allows avoiding life-threatening complications in children with critical congenital heart defects and persistent pulmonary hypertension and in a stable state to transfer them to a further treatment stage.

  19. Saturated Zone Colloid Transport

    International Nuclear Information System (INIS)

    H. S. Viswanathan

    2004-01-01

    This scientific analysis provides retardation factors for colloids transporting in the saturated zone (SZ) and the unsaturated zone (UZ). These retardation factors represent the reversible chemical and physical filtration of colloids in the SZ. The value of the colloid retardation factor, R col is dependent on several factors, such as colloid size, colloid type, and geochemical conditions (e.g., pH, Eh, and ionic strength). These factors are folded into the distributions of R col that have been developed from field and experimental data collected under varying geochemical conditions with different colloid types and sizes. Attachment rate constants, k att , and detachment rate constants, k det , of colloids to the fracture surface have been measured for the fractured volcanics, and separate R col uncertainty distributions have been developed for attachment and detachment to clastic material and mineral grains in the alluvium. Radionuclides such as plutonium and americium sorb mostly (90 to 99 percent) irreversibly to colloids (BSC 2004 [DIRS 170025], Section 6.3.3.2). The colloid retardation factors developed in this analysis are needed to simulate the transport of radionuclides that are irreversibly sorbed onto colloids; this transport is discussed in the model report ''Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]). Although it is not exclusive to any particular radionuclide release scenario, this scientific analysis especially addresses those scenarios pertaining to evidence from waste-degradation experiments, which indicate that plutonium and americium may be irreversibly attached to colloids for the time scales of interest. A section of this report will also discuss the validity of using microspheres as analogs to colloids in some of the lab and field experiments used to obtain the colloid retardation factors. In addition, a small fraction of colloids travels with the groundwater without any significant retardation. Radionuclides irreversibly

  20. The measurement of oxygen in vivo using EPR techniques

    International Nuclear Information System (INIS)

    Swartz, Harold M.; Clarkson, Robert B.

    1998-01-01

    The measurement of pO 2 in vivo using EPR has some features which have already led to very useful applications and this approach is likely to have increasingly wide and effective use. It is based on the effect of oxygen on EPR spectra which provides a sensitive and accurate means to measure pO 2 quantitatively. The development of oxygen-sensitive paramagnetic materials which are very stable, combined with instrumental developments, has been crucial to the in vivo applications of this technique. The physical basis and biological applications of in vivo EPR oximetry are reviewed, with particular emphasis on the use of EPR spectroscopy at 1 GHz using particulate paramagnetic materials for the repetitive and non-invasive measurement of pO 2 in tissues. In vivo EPR has already produced some very useful results which have contributed significantly to solving important biological problems. The characteristics of EPR oximetry which appear to be especially useful are often complementary to existing techniques for measuring oxygen in tissues. These characteristics include the capability of making repeated measurements from the same site, high sensitivity to low levels of oxygen, and non-invasive options. The existing techniques are especially useful for studies in small animals, where the depth of measurements is not an overriding issue. In larger animals and potentially in human subjects, non-invasive techniques seem to be immediately applicable to study phenomena very near the surface (within 10 mm) while invasive techniques have some very promising uses. The clinical uses of EPR oximetry which seem especially promising and likely to be undertaken in the near future are long-term monitoring of the status and response to treatment of peripheral vascular disease and optimizing cancer therapy by enabling it to be modified on the basis of the pO 2 measured in the tumour. (author)

  1. Impact of medical training and clinical experience on the assessment of oxygenation and hypoxaemia after general anaesthesia: an observational study.

    Science.gov (United States)

    Aust, Hansjörg; Kranke, Peter; Eberhart, Leopold H J; Afshari, Arash; Weber, Frank; Brieskorn, Melanie; Heine, Julian; Arndt, Christian; Rüsch, Dirk

    2015-06-01

    In Germany it is common practice to use pulse oximetry and supplementary oxygen only on request in patients breathing spontaneously transferred to the post-anaesthesia care unit (PACU) following surgery under general anaesthesia. The main aim was to study the influence of medical training and clinical experience on assessing SpO(2) and detecting hypoxaemia in these patients. The second aim was to do a preliminary assessment whether this practice can be found in countries other than Germany. Anaesthetists, nurses and medical students estimated SpO(2) in patients breathing room air at the end of transfer to the PACU following surgery (including all major surgical fields) under general anaesthesia. Estimated SpO(2) was compared to SpO(2) measured by pulse oximetry. A survey was carried out among European anaesthesists concerning the use of pulse oximetry and supplementary oxygen during patient transfer to the PACU. Hypoxaemia (SpO(2) < 90 %) occurred in 154 (13.5 %) out of 1,138 patients. Anaesthetists, nurses, and medical students identified only 25, 23, and 21 patients of those as being hypoxaemic, respectively. Clinical experience did not improve detection of hypoxaemia both in anaesthetists (p = 0.63) and nurses (p = 0.18). Use of pulse oximetry and supplemental oxygen during patient transfer to the PACU in European countries differs to a large extent. It seems to be applied only on request in many hospitals. Considering the uncertainty about deleterious effects of transient, short lasting hypoxaemia routine use of pulse oximetry is advocated for patient transfer to the PACU.

  2. A History of Mild Traumatic Brain Injury affects Peripheral Pulse Oximetry during Normobaric Hypoxia

    Directory of Open Access Journals (Sweden)

    Leonard Temme

    2016-09-01

    Full Text Available Introduction: Physiological and emotional stressors increase symptoms of concussion in recently injured individuals and both forms of stress induce symptoms in people recovering from mild traumatic brain injury (mTBI but who are asymptomatic when not stressed or are at rest. Methods: Healthy asymptomatic adults (25.0 ± 5.1 years with a history of mTBI (n = 36 and matched healthy controls (n = 36 with no mTBI history were exposed to three levels of normobaric hypoxic stress generated with the Reduced Oxygen Breathing Device (ROBD (Environics, Inc., Tollande, CT, which reduced the percent oxygen by mixing sea level air with nitrogen. The ROBD reduced the percent oxygen in the breathable air from the normal 21% to 15.5% O2, 14% O2, and 13% O2. Under these conditions: (a a standard pulse oximeter recorded peripheral oxygen saturation (SpO2 and pulse rate (beats per minute, and (b the FIT (PMI, Inc., Rockville, MD recorded saccadic velocity and pupillary response dynamics to a brief light flash. Results: For all three hypoxic stress conditions the mTBI group had significantly higher SpO2 during the final minute of exposure than did the controls F(2.17,151.8 = 5.29, p < .001, η2 = .852 and the rate of SpO2 change over time was significantly shallower for the mTBI than for the controls F(2.3,161.3 = 2.863, p < .001, η2 = .569, Greenhouse-Geisser corrected. Overall, mTBI had lower pulse rate but the difference was only significant for the 14% O2 condition. FIT oculomotor measures were not sensitive to group differences. When exposed to mild or moderate normobaric hypoxic stress (15% O2: (1 SpO2 differences emerged between the mTBI and matched healthy controls, (2 heart rate trended lower in the mTBI group, and (3 FIT measures were not sensitive to group differences. Conclusion: A relatively minor hypoxic challenge can reveal measurable differences in SpO2 and heart rate in otherwise asymptomatic individuals with a history of mTBI.

  3. Mapping of calf muscle oxygenation and haemoglobin content during dynamic plantar flexion exercise by multi-channel time-resolved near-infrared spectroscopy

    International Nuclear Information System (INIS)

    Torricelli, Alessandro; Quaresima, Valentina; Pifferi, Antonio; Biscotti, Giovanni; Spinelli, Lorenzo; Taroni, Paola; Ferrari, Marco; Cubeddu, Rinaldo

    2004-01-01

    A compact and fast multi-channel time-resolved near-infrared spectroscopy system for tissue oximetry was developed. It employs semiconductor laser and fibre optics for delivery of optical signals. Photons are collected by eight 1 mm fibres and detected by a multianode photomultiplier. A time-correlated single photon counting board is used for the parallel acquisition of time-resolved reflectance curves. Estimate of the reduced scattering coefficient is achieved by fitting with a standard model of diffusion theory, while the modified Lambert-Beer law is used to assess the absorption coefficient. In vivo measurements were performed on five healthy volunteers to monitor spatial changes in calf muscle (medial and lateral gastrocnemius; MG, LG) oxygen saturation (SmO 2 ) and total haemoglobin concentration (tHb) during dynamic plantar flexion exercise performed at 50% of the maximal voluntary contraction. At rest SmO 2 was 73.0 ± 0.9 and 70.5 ± 1.7% in MG and LG, respectively (P = 0.045). At the end of the exercise, SmO 2 decreased (69.1 ± 1.8 and 63.8 ± 2.1% in MG and LG, respectively; P 2 and tHb

  4. Oxygen requirement of separated hybrid catfish eggs

    Science.gov (United States)

    Channel catfish egg masses require hatchery water with over 7.8 ppm dissolved oxygen at 80° F (95% air saturation) to maintain maximum oxygen consumption as they near hatching. This concentration is called the critical oxygen requirement by scientists but for the purpose of this article we will call...

  5. Saturated Zone Colloid Transport

    Energy Technology Data Exchange (ETDEWEB)

    H. S. Viswanathan

    2004-10-07

    This scientific analysis provides retardation factors for colloids transporting in the saturated zone (SZ) and the unsaturated zone (UZ). These retardation factors represent the reversible chemical and physical filtration of colloids in the SZ. The value of the colloid retardation factor, R{sub col} is dependent on several factors, such as colloid size, colloid type, and geochemical conditions (e.g., pH, Eh, and ionic strength). These factors are folded into the distributions of R{sub col} that have been developed from field and experimental data collected under varying geochemical conditions with different colloid types and sizes. Attachment rate constants, k{sub att}, and detachment rate constants, k{sub det}, of colloids to the fracture surface have been measured for the fractured volcanics, and separate R{sub col} uncertainty distributions have been developed for attachment and detachment to clastic material and mineral grains in the alluvium. Radionuclides such as plutonium and americium sorb mostly (90 to 99 percent) irreversibly to colloids (BSC 2004 [DIRS 170025], Section 6.3.3.2). The colloid retardation factors developed in this analysis are needed to simulate the transport of radionuclides that are irreversibly sorbed onto colloids; this transport is discussed in the model report ''Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]). Although it is not exclusive to any particular radionuclide release scenario, this scientific analysis especially addresses those scenarios pertaining to evidence from waste-degradation experiments, which indicate that plutonium and americium may be irreversibly attached to colloids for the time scales of interest. A section of this report will also discuss the validity of using microspheres as analogs to colloids in some of the lab and field experiments used to obtain the colloid retardation factors. In addition, a small fraction of colloids travels with the groundwater without any significant

  6. nitrogen saturation in stream ecosystems

    OpenAIRE

    Earl, S. R.; Valett, H. M.; Webster, J. R.

    2006-01-01

    The concept of nitrogen (N) saturation has organized the assessment of N loading in terrestrial ecosystems. Here we extend the concept to lotic ecosystems by coupling Michaelis-Menten kinetics and nutrient spiraling. We propose a series of saturation response types, which may be used to characterize the proximity of streams to N saturation. We conducted a series of short-term N releases using a tracer ((NO3)-N-15-N) to measure uptake. Experiments were conducted in streams spanning a gradient ...

  7. Changes in oxygen partial pressure of brain tissue in an animal model of obstructive apnea

    Directory of Open Access Journals (Sweden)

    Torres Marta

    2010-01-01

    Full Text Available Abstract Background Cognitive impairment is one of the main consequences of obstructive sleep apnea (OSA and is usually attributed in part to the oxidative stress caused by intermittent hypoxia in cerebral tissues. The presence of oxygen-reactive species in the brain tissue should be produced by the deoxygenation-reoxygenation cycles which occur at tissue level during recurrent apneic events. However, how changes in arterial blood oxygen saturation (SpO2 during repetitive apneas translate into oxygen partial pressure (PtO2 in brain tissue has not been studied. The objective of this study was to assess whether brain tissue is partially protected from intermittently occurring interruption of O2 supply during recurrent swings in arterial SpO2 in an animal model of OSA. Methods Twenty-four male Sprague-Dawley rats (300-350 g were used. Sixteen rats were anesthetized and non-invasively subjected to recurrent obstructive apneas: 60 apneas/h, 15 s each, for 1 h. A control group of 8 rats was instrumented but not subjected to obstructive apneas. PtO2 in the cerebral cortex was measured using a fast-response oxygen microelectrode. SpO2 was measured by pulse oximetry. The time dependence of arterial SpO2 and brain tissue PtO2 was carried out by Friedman repeated measures ANOVA. Results Arterial SpO2 showed a stable periodic pattern (no significant changes in maximum [95.5 ± 0.5%; m ± SE] and minimum values [83.9 ± 1.3%]. By contrast, brain tissue PtO2 exhibited a different pattern from that of arterial SpO2. The minimum cerebral cortex PtO2 computed during the first apnea (29.6 ± 2.4 mmHg was significantly lower than baseline PtO2 (39.7 ± 2.9 mmHg; p = 0.011. In contrast to SpO2, the minimum and maximum values of PtO2 gradually increased (p 2 were significantly greater relative to baseline and the first apnea dip, respectively. Conclusions These data suggest that the cerebral cortex is partially protected from intermittently occurring interruption of

  8. Saturação venosa central e mista de oxigênio no choque séptico: existe diferença clinicamente relevante? Central and mixed venous oxygen saturation in septic shock: is there a clinically relevant difference?

    Directory of Open Access Journals (Sweden)

    Flavia Ribeiro Machado

    2008-12-01

    Full Text Available INTRODUÇÃO: A medida da saturação venosa central de oxigênio (SvcO2 tem sido proposta como alternativa a saturação venosa mista (SvO2, com grau de concordância variável nos dados atualmente disponíveis. Esse estudo objetivou avaliar as possíveis diferenças entre a SvO2 e a SvcO2 ou saturação venosa atrial de oxigênio (SvaO2, com ênfase na interferência do débito cardíaco, e o impacto delas no manejo clínico do paciente séptico. MÉTODOS: Estudo prospectivo observacional em pacientes com choque séptico monitorizados com cateter de artéria pulmonar. Foi obtido sangue simultaneamente para determinação da SvcO2, SvO2 e SvaO2. Realizado testes de correlação linear (significativos se pINTRODUCTION: Central venous oxygen saturation (SvcO2 has been proposed as an alternative for mixed venous oxygen saturation (SvO2, with a variable level of acceptance according to available data. This study aimed to evaluate possible differences between SvO2 and SvcO2 or atrial venous saturation (SvaO2, with emphasis on the role of cardiac output and their impact on clinical management of the septic patient. METHODS: This is an observational, prospective study of patients with septic shock monitored by pulmonary artery catheter. Blood was obtained simultaneously for SvcO2, SvO2 and SvaO2 determination. Linear correlation (significant if p<0.05 and agreement analysis (Bland-Altman were performed with samples and subgroups according to cardiac output. Moreover, agreement about clinical management based on these samples was evaluated. RESULTS: Sixty one measurements from 23 patients were obtained, median age of 65.0 (49.0-75.0 years and mean APACHE II of 27.7±6.3. Mean values of SvO2, SvcO2 and SvaO2 were 72.20±8.26%, 74.61±7.60% and 74.64±8.47%. Linear correlation test showed a weak correlation between SvO2 and SvcO2 (r=0.61, p<0.0001 and also between SvO2 and SvaO2 (r=0.70, p<0.0001. Agreements between SvcO2/SvO2 and SvaO2/SvO2 were -2.40

  9. Saturation and linear transport equation

    International Nuclear Information System (INIS)

    Kutak, K.

    2009-03-01

    We show that the GBW saturation model provides an exact solution to the one dimensional linear transport equation. We also show that it is motivated by the BK equation considered in the saturated regime when the diffusion and the splitting term in the diffusive approximation are balanced by the nonlinear term. (orig.)

  10. Pulse Oximetry Screening Adapted to a System with Home Births: The Dutch Experience

    Directory of Open Access Journals (Sweden)

    Ilona C. Narayen

    2018-03-01

    Full Text Available Neonatal screening for critical congenital heart defects is proven to be safe, accurate, and cost-effective. The screening has been implemented in many countries across all continents in the world. However, screening for critical congenital heart defects after home births had not been studied widely yet. The Netherlands is known for its unique perinatal care system with a high rate of home births (18% and early discharge after an uncomplicated delivery in hospital. We report a feasibility, accuracy, and acceptability study performed in the Dutch perinatal care system. Screening newborns for critical congenital heart defects using pulse oximetry is feasible after home births and early discharge, and acceptable to mothers. The accuracy of the test is comparable to other early-screening settings, with a moderate sensitivity and high specificity.

  11. Hypoxia, Color Vision Deficiencies, and Blood Oxygen Saturation

    Science.gov (United States)

    2013-11-01

    using the Dvorine Pseudoisochromatic Plate Test (2nd edition, Psychological Corporation, Baltimore, MD) illuminated by True Daylight Illuminator T8...Plant, G.T. (1994). Insights into the different exploits of colour in the visual cortex. Proc Biol Sci, 258 (1353), 327-334. Barbur, J.L...Aviat Space Environ Med, 80, 933-940. Crow, T.J.,& Kelman, G.R.(1973). Psychological effects of mild acute hypoxia. Br J Anaesth, 45, 335-337

  12. Hypoxia, color vision deficiencies, and blood oxygen saturation.

    Science.gov (United States)

    2013-11-01

    Chromatic thresholds were measured using the Cambridge Color Test (CCT), Color Assessment and Diagnosis : (CAD) test, and Cone Specific Contrast Test at ground and 3780 m (12,400 ft) for subjects with normal color : vision and red-green color vision ...

  13. Computer Modeling of Acceleration Effects on Cerebral Oxygen Saturation

    Science.gov (United States)

    2007-04-01

    a significant physiological threat to etrate the cranium and enter the cerebral cortex. Hongo high-performance aircraft pilots since the development...et al. and Hongo et al. (7,8). blackened out and all that could be seen was the target, The primary focus of this effort was to build a model i.e...O6GInduced.html. 87:402. 12. Tripp LD, Arnold A, Bagian J, et al. Psychophysiological effects 8. Hongo K, Kobayashi S, Okudera H, et al. Noninvasive cerebral of

  14. Cerebral oximetry monitoring in the management of severe hypoxaemia associated with transposition of the great arteries with balloon atrial septostomy.

    Science.gov (United States)

    Pérez Moreno, J C; Nájera Losada, D C; Sanabria Carretero, P; Paredes Lacave, Á; Benito Bartolomé, F

    2018-05-01

    Transposition of the great arteries (D-TGA) is one of the most common congenital heart diseases requiring neonatal surgical intervention. In the desperately ill neonate with TGA and the resultant hypoxaemia, acidemia, and congestive heart failure, improvement is often obtained with balloon atrial septostomy (BAS). Current methods employed to evaluate oxygen delivery and tissue consumption are frequently nonspecific. Near infrared spectroscopy (NIRS) allows a continuous non-invasive measurement of tissue oxygenation which reflects perfusion status in real time. Because little is known about the direct effect of BAS on the neonatal brain and on cerebral oxygenation, we measured the effectiveness of BAS in two patients with D-TGA using NIRS before and after BAS. We concluded BAS improves cerebral oxygen saturation in neonates with D-TGA. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Determination of oxygen in liquid sodium

    International Nuclear Information System (INIS)

    Torre, M. de la; Lapena, J.; Galindo, F.; Couchoud, M.; Celis, B. de; Lopez-Araquistain, J.L.

    1976-01-01

    The behaviour is analysed of a device for 'in-line' sampling and vacuum distillation. With this procedure 95 results were obtained for the solubility of oxygen in liquid sodium at temperatures between 125 0 and 300 0 C. The correlation between the concentration of oxygen in a saturation state and the corresponding temperature is represented by: 1g C = 6,17 - 2398/T, where C expressed ppm of oxygen by weight and T is the saturation temperature in 0 K. Reference is also made to the first results obtained with the electrochemical oxygen meter and the system for taking and recording data. (author)

  16. Electron paramagnetic resonance highlights that the oxygen effect contributes to the radiosensitizing effect of paclitaxel.

    Directory of Open Access Journals (Sweden)

    Fabienne Danhier

    Full Text Available BACKGROUND: Paclitaxel (PTX is a potent anti-cancer chemotherapeutic agent and is widely used in the treatments of solid tumors, particularly of the breast and ovaries. An effective and safe micellar formulation of PTX was used to administer higher doses of PTX than Taxol® (the current commercialized drug. We hypothesize that PTX-loaded micelles (M-PTX may enhance tumor radiosensitivity by increasing the tumor oxygenation (pO(2. Our goals were (i to evaluate the contribution of the "oxygen effect" to the radiosensitizing effect of PTX; (ii to demonstrate the therapeutic relevance of the combination of M-PTX and irradiation and (iii to investigate the underlying mechanisms of the observed oxygen effect. METHODOLOGY AND PRINCIPAL FINDINGS: We used (PEG-p-(CL-co-TMC polymeric micelles to solubilize PTX. pO(2 was measured on TLT tumor-bearing mice treated with M-PTX (80 mg/kg using electron paramagnetic resonance (EPR oximetry. The regrowth delay following 10 Gy irradiation 24 h after M-PTX treatment was measured. The tumor perfusion was assessed by the patent blue staining. The oxygen consumption rate and the apoptosis were evaluated by EPR oximetry and the TUNEL assay, respectively. EPR oximetry experiments showed that M-PTX dramatically increases the pO(2 24 h post treatment. Regrowth delay assays demonstrated a synergy between M-PTX and irradiation. M-PTX increased the tumor blood flow while cells treated with M-PTX consumed less oxygen and presented more apoptosis. CONCLUSIONS: M-PTX improved the tumor oxygenation which leads to synergy between this treatment and irradiation. This increased pO(2 can be explained both by an increased blood flow and an inhibition of O(2 consumption.

  17. Repeated tumor pO2 measurements by multi-site EPR oximetry as a prognostic marker for enhanced therapeutic efficacy of fractionated radiotherapy

    International Nuclear Information System (INIS)

    Hou Huagang; Lariviere, Jean P.; Demidenko, Eugene; Gladstone, David; Swartz, Harold; Khan, Nadeem

    2009-01-01

    Purpose: To investigate the temporal effects of single or fractionated radiotherapy on subcutaneous RIF-1 tumor pO 2 and to determine the therapeutic outcomes when the timing of fractionations is guided by tumor pO 2 . Methods: The time-course of the tumor pO 2 changes was followed by multi-site electron paramagnetic resonance (EPR) oximetry. The tumors were treated with single 10, 20, and 10 Gy x 2 doses, and the tumor pO 2 was measured repeatedly for six consecutive days. In the 10 Gy x 2 group, the second dose of 10 Gy was delivered at a time when the tumors were either relatively oxygenated or hypoxic. The changes in tumor volumes were followed for nine days to determine the therapeutic outcomes. Results: A significant increase in tumor pO 2 was observed at 24 h post 10 Gy, while 20 Gy resulted in a significant increase in tumor pO 2 at 72-120 h post irradiation. The tumors irradiated with a second dose of 10 Gy at 24 h, when the tumors were oxygenated, had a significant increase in tumor doubling times (DTs), as compared to tumors treated at 48 h when they were hypoxic (p 2 repeatedly during fractionated schemes to optimize radiotherapeutic outcome. This technique could also be used to identify responsive and non-responsive tumors, which will facilitate the design of other therapeutic approaches for non-responsive tumors at early time points during the course of therapy.

  18. Landsliding in partially saturated materials

    Science.gov (United States)

    Godt, J.W.; Baum, R.L.; Lu, N.

    2009-01-01

    [1] Rainfall-induced landslides are pervasive in hillslope environments around the world and among the most costly and deadly natural hazards. However, capturing their occurrence with scientific instrumentation in a natural setting is extremely rare. The prevailing thinking on landslide initiation, particularly for those landslides that occur under intense precipitation, is that the failure surface is saturated and has positive pore-water pressures acting on it. Most analytic methods used for landslide hazard assessment are based on the above perception and assume that the failure surface is located beneath a water table. By monitoring the pore water and soil suction response to rainfall, we observed shallow landslide occurrence under partially saturated conditions for the first time in a natural setting. We show that the partially saturated shallow landslide at this site is predictable using measured soil suction and water content and a novel unified effective stress concept for partially saturated earth materials. Copyright 2009 by the American Geophysical Union.

  19. Nitrogen saturation in stream ecosystems.

    Science.gov (United States)

    Earl, Stevan R; Valett, H Maurice; Webster, Jackson R

    2006-12-01

    The concept of nitrogen (N) saturation has organized the assessment of N loading in terrestrial ecosystems. Here we extend the concept to lotic ecosystems by coupling Michaelis-Menten kinetics and nutrient spiraling. We propose a series of saturation response types, which may be used to characterize the proximity of streams to N saturation. We conducted a series of short-term N releases using a tracer (15NO3-N) to measure uptake. Experiments were conducted in streams spanning a gradient of background N concentration. Uptake increased in four of six streams as NO3-N was incrementally elevated, indicating that these streams were not saturated. Uptake generally corresponded to Michaelis-Menten kinetics but deviated from the model in two streams where some other growth-critical factor may have been limiting. Proximity to saturation was correlated to background N concentration but was better predicted by the ratio of dissolved inorganic N (DIN) to soluble reactive phosphorus (SRP), suggesting phosphorus limitation in several high-N streams. Uptake velocity, a reflection of uptake efficiency, declined nonlinearly with increasing N amendment in all streams. At the same time, uptake velocity was highest in the low-N streams. Our conceptual model of N transport, uptake, and uptake efficiency suggests that, while streams may be active sites of N uptake on the landscape, N saturation contributes to nonlinear changes in stream N dynamics that correspond to decreased uptake efficiency.

  20. Use of pulse co-oximetry as a screening and monitoring tool in mass carbon monoxide poisoning.

    Science.gov (United States)

    Bledsoe, Bryan E; Nowicki, Kevin; Creel, James H; Carrison, Dale; Severance, Harry W

    2010-01-01

    Carbon monoxide (CO) poisoning remains a common cause of poisoning in the United States. We describe a case where responding fire department personnel encountered a sick employee with a headache at an automotive brake manufacturing plant. Using both atmospheric CO monitoring and pulse CO-oximetry technology, fire department personnel were able to diagnose the cause of the patient's illness and later identify the source of CO in the plant.

  1. Oxygen concentration inside a functioning photosynthetic cell.

    Science.gov (United States)

    Kihara, Shigeharu; Hartzler, Daniel A; Savikhin, Sergei

    2014-05-06

    The excess oxygen concentration in the photosynthetic membranes of functioning oxygenic photosynthetic cells was estimated using classical diffusion theory combined with experimental data on oxygen production rates of cyanobacterial cells. The excess oxygen concentration within the plesiomorphic cyanobacterium Gloeobactor violaceus is only 0.025 μM, or four orders of magnitude lower than the oxygen concentration in air-saturated water. Such a low concentration suggests that the first oxygenic photosynthetic bacteria in solitary form could have evolved ∼2.8 billion years ago without special mechanisms to protect them against reactive oxygen species. These mechanisms instead could have been developed during the following ∼500 million years while the oxygen level in the Earth's atmosphere was slowly rising. Excess oxygen concentrations within individual cells of the apomorphic cyanobacteria Synechocystis and Synechococcus are 0.064 and 0.25 μM, respectively. These numbers suggest that intramembrane and intracellular proteins in isolated oxygenic photosynthetic cells are not subjected to excessively high oxygen levels. The situation is different for closely packed colonies of photosynthetic cells. Calculations show that the excess concentration within colonies that are ∼40 μm or larger in diameter can be comparable to the oxygen concentration in air-saturated water, suggesting that species forming colonies require protection against reactive oxygen species even in the absence of oxygen in the surrounding atmosphere. Copyright © 2014 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  2. Oxygen toxicity

    Directory of Open Access Journals (Sweden)

    C. A. van der Westhuizen

    1990-07-01

    Full Text Available Oxygen has been discovered about 200 years ago. Since then the vital physiological involvement of oxygen in various biologi­cal processes, mainly energy production, has been established. However, in the body molecular oxygen can be converted to toxic oxygen metabolites such as superoxide anion, hydrogen peroxide, the hydroxyl radical and singlet oxygen. These toxic metabolites are produced mainly in the mitochondria, plasma membranes and endoplasmic reticulum.

  3. A new through-tubing oil-saturation measurement system

    International Nuclear Information System (INIS)

    Roscoe, B.A.; Adolph, R.A.; Bontemy, Y.; Cheeseborough, J.C. III; Hall, J.S.; McKeon, D.C.; Pittman, D.; Seeman, B.; Thomas, S.R. Jr.

    1991-01-01

    This paper reports on carbon-oxygen logging which is used primarily to estimate oil saturation in cased-hole conditions when the formation water is fresh or unknown. The drawbacks of current techniques are: slow logging speed, large tool diameter, and excessive sensitivity to borehole fluid composition. A new, slim, neutron-induced gamma ray spectroscopy logging system has been developed to overcome some of these limitations. The new logging service is called the Reservoir Saturation (RST) Tool. Initial field tests are being carried out in the Middle East. The RST tool uses multiple detectors to separate the signal contributions from the borehole and the formation. Therefore, even when the borehole fluid composition is unknown, oil saturation can be determined in addition to the borehole oil fraction. This presents the possibility of logging flowing wells, which ensures that reinvasion and crossflow will not affect the results, and eliminates the costs of well preparation

  4. The evaluation of new and isotopically labeled isoindoline nitroxides and an azaphenalene nitroxide for EPR oximetry

    Science.gov (United States)

    Khan, Nadeem; Blinco, James P.; Bottle, Steven E.; Hosokawa, Kazuyuki; Swartz, Harold M.; Micallef, Aaron S.

    2011-01-01

    Isoindoline nitroxides are potentially useful probes for viable biological systems, exhibiting low cytotoxicity, moderate rates of biological reduction and favorable Electron Paramagnetic Resonance (EPR) characteristics. We have evaluated the anionic (5-carboxy-1,1,3,3-tetramethylisoindolin-2-yloxyl; CTMIO), cationic (5-(N,N,N-trimethylammonio)-1,1,3,3-tetramethylisoindolin-2-yloxyl iodide, QATMIO) and neutral (1,1,3,3-tetramethylisoindolin-2-yloxyl; TMIO) nitroxides and their isotopically labeled analogues (2H12- and/or 2H12-15N-labeled) as potential EPR oximetry probes. An active ester analogue of CTMIO, designed to localize intracellularly, and the azaphenalene nitroxide 1,1,3,3-tetramethyl-2,3-dihydro-2-azaphenalen-2-yloxyl (TMAO) were also studied. While the EPR spectra of the unlabeled nitroxides exhibit high sensitivity to O2 concentration, deuteration resulted in a loss of superhyperfine features and a subsequent reduction in O2 sensitivity. Labeling the nitroxides with 15N increased the signal intensity and this may be useful in decreasing the detection limits for in vivo measurements. The active ester nitroxide showed approximately 6% intracellular localization and low cytotoxicity. The EPR spectra of TMAO nitroxide indicated an increased rigidity in the nitroxide ring, due to dibenzo-annulation. PMID:21665499

  5. Effect of regional cerebral oximetry to estimate neurologic prognostic outcomes in patients administered targeted temperature management.

    Science.gov (United States)

    Sarıtaş, Aykut; Çinleti, Burcu Acar; Zincircioğlu, Çiler; Uzun, Uğur; Köse, Işıl; Şenoğlu, Nimet

    2018-04-09

    The aim of our study is to research the role and efficacy of cerebral oximetry in predicting neurologic prognosis when applied during TTM to patients experiencing coma after CA. This study was performed on surviving adult comatose patients after CA treated with TTM. The average scores of rSO 2 was measured at 6h intervals for the first 2days and once a day for the following 3days with a NIRS device during TTM. The CPC scale was used to define the neurologic outcomes of patients. We compared the correlations of rSO 2 values between good (CPC 1-2) and poor (CPC 3-5) neurologic outcomes in CA patients. There was no statistically significant difference identified between the prognosis groups in terms of rSO 2 , CPR durations, hemoglobin values and admission body temperature (p>0.05). When the variation in rSO 2 values over time is investigated, though there was no significant difference between the good and poor prognosis groups, it appeared to fall in the first 6h in both prognosis groups. The median NT-proBNP and lactate values were observed to be higher in the poor prognosis group. There is no significant correlation between rSO 2 values and neurologic outcomes. Multimodal monitoring methods may be useful and further studies with a larger patient population are necessary in this area. Copyright © 2018. Published by Elsevier Inc.

  6. Laser Doppler Flowmetry and Transcutaneous Oximetry in Chronic Skin Ulcers: A Comparative Evaluation.

    Science.gov (United States)

    Raposio, Edoardo; Bertozzi, Nicolò; Moretti, Rebecca; Grignaffini, Eugenio; Grieco, Michele P

    2017-07-01

    Laser Doppler Flowmetry (LDF) and transcutaneous oximetry (TcpO2) are established methods for investigating cutaneous perfusion. To date, no study previously performed has compared data obtained from these 2 methodologies in cases of chronic cutaneous ulcers. Laser Doppler Flowmetry and TcpO2 were performed in 25 consecutive outpatients with chronic lower limb ulcers (group A, experimental; 9 women and 16 men; mean age 67 years [range, 52-81 years]) and 25 age- and sex-matched healthy control subjects (group B, control) enrolled for the study. Ulcer aetiologies included 12 peripheral arterial occlusive disease, 9 chronic venous insufficiencies, and 4 pressure ulcers. Data were analyzed with Shapiro-Wilk and Wilcoxon-Mann-Whitney tests. A statistically significant difference (P < .05) was found between LDF values of the 2 groups. No statistically significant differences were found between the 2 groups regarding the TcpO2 measurements. The data confirmed the soundness of LDF while investigating local perfusion in patients with chronic cutaneous ulcers. The same diagnostic accuracy was not obtained by means of TcpO2.

  7. Optical characterization of two-layered turbid media for non-invasive, absolute oximetry in cerebral and extracerebral tissue.

    Directory of Open Access Journals (Sweden)

    Bertan Hallacoglu

    Full Text Available We introduce a multi-distance, frequency-domain, near-infrared spectroscopy (NIRS method to measure the optical coefficients of two-layered media and the thickness of the top layer from diffuse reflectance measurements. This method features a direct solution based on diffusion theory and an inversion procedure based on the Levenberg-Marquardt algorithm. We have validated our method through Monte Carlo simulations, experiments on tissue-like phantoms, and measurements on the forehead of three human subjects. The Monte Carlo simulations and phantom measurements have shown that, in ideal two-layered samples, our method accurately recovers the top layer thickness (L, the absorption coefficient (µ a and the reduced scattering coefficient (µ' s of both layers with deviations that are typically less than 10% for all parameters. Our method is aimed at absolute measurements of hemoglobin concentration and saturation in cerebral and extracerebral tissue of adult human subjects, where the top layer (layer 1 represents extracerebral tissue (scalp, skull, dura mater, subarachnoid space, etc. and the bottom layer (layer 2 represents cerebral tissue. Human subject measurements have shown a significantly greater total hemoglobin concentration in cerebral tissue (82±14 µM with respect to extracerebral tissue (30±7 µM. By contrast, there was no significant difference between the hemoglobin saturation measured in cerebral tissue (56%±10% and extracerebral tissue (62%±6%. To our knowledge, this is the first time that an inversion procedure in the frequency domain with six unknown parameters with no other prior knowledge is used for the retrieval of the optical coefficients and top layer thickness with high accuracy on two-layered media. Our absolute measurements of cerebral hemoglobin concentration and saturation are based on the discrimination of extracerebral and cerebral tissue layers, and they can enhance the impact of NIRS for cerebral hemodynamics and

  8. Accuracy of carboxyhemoglobin detection by pulse CO-oximetry during hypoxemia.

    Science.gov (United States)

    Feiner, John R; Rollins, Mark D; Sall, Jeffrey W; Eilers, Helge; Au, Paul; Bickler, Philip E

    2013-10-01

    Carbon monoxide poisoning is a significant problem in most countries, and a reliable method of quick diagnosis would greatly improve patient care. Until the recent introduction of a multiwavelength "pulse CO-oximeter" (Masimo Rainbow SET(®) Radical-7), obtaining carboxyhemoglobin (COHb) levels in blood required blood sampling and laboratory analysis. In this study, we sought to determine whether hypoxemia, which can accompany carbon monoxide poisoning, interferes with the accurate detection of COHb. Twelve healthy, nonsmoking, adult volunteers were fitted with 2 standard pulse-oximeter finger probes and 2 Rainbow probes for COHb detection. A radial arterial catheter was placed for blood sampling during 3 interventions: (1) increasing hypoxemia in incremental steps with arterial oxygen saturations (SaO2) of 100% to 80%; (2) normoxia with incremental increases in %COHb to 12%; and (3) elevated COHb combined with hypoxemia with SaO2 of 100% to 80%. Pulse-oximeter (SpCO) readings were compared with simultaneous arterial blood values at the various increments of hypoxemia and carboxyhemoglobinemia (≈25 samples per subject). Pulse CO-oximeter performance was analyzed by calculating the mean bias (SpCO - %COHb), standard deviation of the bias (precision), and the root-mean-square error (A(rms)). The Radical-7 accurately detected hypoxemia with both normal and elevated levels of COHb (bias mean ± SD: 0.44% ± 1.69% at %COHb <4%, and -0.29% ± 1.64% at %COHb ≥4%, P < 0.0001, and A(rms) 1.74% vs 1.67%). COHb was accurately detected during normoxia and moderate hypoxia (bias mean ± SD: -0.98 ± 2.6 at SaO2 ≥95%, and -0.7 ± 4.0 at SaO2 <95%, P = 0.60, and A(rms) 2.8% vs 4.0%), but when SaO2 decreased below approximately 85%, the pulse CO-oximeter always gave low signal quality errors and did not report SpCO values. In healthy volunteers, the Radical-7 pulse CO-oximeter accurately detects hypoxemia with both low and elevated COHb levels, and accurately detects COHb

  9. Efeitos do salbutamol e do formoterol sobre pressão arterial, frequência cardíaca e saturação de oxigénio em asmáticos, durante uma hora One hour effects of salbutamol and formoterol on blood pressure, heart rate and oxygen saturation in asthmatics

    Directory of Open Access Journals (Sweden)

    Geraldo Andrade Capuchinho-Júnior

    2008-06-01

    Full Text Available Objectivo: Analisar os possíveis efeitos do uso de β -2 -agonistas, de curta e longa duração, nas pressões arteriais sistólica (PAS e diastólica (PAD, na saturação parcial de oxigénio (SpO2 e na frequência cardíaca (FC, durante o período de uma hora. Material e métodos: Vinte e quatro doentes com asma persistente grave, em tratamento no ambulatório de Pneumologia do Hospital Universitário Gaffrée e Guinle, foram seleccionados para um ensaio clínico sequencial e cruzado. Os valores da PAS, PAD, SpO2 e FC foram registados antes e após o uso de broncodilatadores, salbutamol 400 µg e formoterol 12 µg, em dias diferentes, com intervalo mínimo de 24 horas. Resultados: Todos os doentes apresentaram distúrbio ventilatório obstrutivo, identificado pela redução da relação entre o volume expiratório forçado no primeiro segundo (VEMS e a capacidade vital forçada (CVF. Após o uso de substância broncodilatadora, não houve variação significativa nas PAS e PAD, nem na FC; porém, a SpO2 aumentou com o uso de salbutamol. Conclusão: Não foram observadas alterações hemodinâmicas significativas após o uso de salbutamol e formoterol nas doses preconizadas.Aim: To analyse systolic (SBP and diastolic blood pressure (DBP, partial oxygen saturation (SpO2 and heart rate (HR disorders for an hour after short and long acting ß2-agonists. Material and methods: Twenty-four severe persistent asthma Pulmonology outpatients at Hospital Universitário Gaffrée e Guinle were selected. SBP, DBP, SpO2 and HR values were determined before and after 400 µg of salbutamol and 12 µg of formoterol, on different days, with a minimum interval of 24 hours. Results: All patients showed ventilatory obstruction, as seen by a reduced FEV1/FVC ratio. There was no statistical SBP/DBP/HR difference after bronchodilator agents, but SpO2 increased with salbutamol. Conclusion: A standard dose of salbutamol and formoterol does not cause haemodynamic

  10. Oxygen Therapy

    Science.gov (United States)

    ... their breathing to dangerously low levels. Will I need oxygen when I sleep? Usually if you use supplemental oxygen during the ... your health care provider tells you you only need to use oxygen for exercise or sleep. Even if you feel “fine” off of your ...

  11. Description of saturation curves and boiling process of dry air

    Directory of Open Access Journals (Sweden)

    Vestfálová Magda

    2018-01-01

    Full Text Available Air is a mixture of gases forming the gas wrap of Earth. It is formed by dry air, moisture and other pollutants. Dry air is a substance whose thermodynamic properties in gaseous state, as well as the thermodynamic properties of its main constituents in gaseous state, are generally known and described in detail in the literature. The liquid air is a bluish liquid and is industrially used to produce oxygen, nitrogen, argon and helium by distillation. The transition between the gaseous and liquid state (the condensation process, resp. boiling process, is usually displayed in the basic thermodynamic diagrams using the saturation curves. The saturation curves of all pure substances are of a similar shape. However, since the dry air is a mixture, the shapes of its saturation curves are modified relative to the shapes corresponding to the pure substances. This paper deals with the description of the dry air saturation curves as a mixture, i.e. with a description of the process of phase change of dry air (boiling process. The dry air saturation curves are constructed in the basic thermodynamic charts based on the values obtained from the literature. On the basis of diagrams, data appearing in various publications are interpreted and put into context with boiling process of dry air.

  12. Oxygen Therapy

    Directory of Open Access Journals (Sweden)

    Bonnie Solmes

    2000-01-01

    Full Text Available LTOT is prescribed for people with chronic lung disease in whom there is a decrease in the ability of the lungs to supply enough oxygen to the body. The heart is obliged to pump faster to meet the body's oxygen requirements. This may place undue stress on the heart, resulting in palpitations, dizziness and fatigue. A low oxygen level in arterial blood is also harmful to the heart, the brain and the pulmonary blood vessels. Oxygen therapy is used to break this cycle. A person with low blood oxygen will often be able to accomplish more with less fatigue with the help of supplemental oxygen therapy. Shortness of breath is a mechanical problem resulting from the effects of chronic obstructive pulmonary disease. Oxygen therapy may or may not reduce shortness of breath, but it will help the lungs and heart to function with less stress.

  13. Can we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?

    Directory of Open Access Journals (Sweden)

    Pedram Niknafs

    2015-05-01

    Full Text Available Neonates with respiratory distress syndrome (RDS, who are treated according to INSURE protocol; require arterial blood gas (ABG analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS, 7.2% were found to have one or more of the followings: acidosis, hypercapnia, or hypoxemia. We found that pulse oximetry in the detection of hyperoxemia had a good validity to appropriately manage patients without blood gas analysis. However, the validity of pulse oximetry was not good enough to detect acidosis, hypercapnia, and hypoxemia.

  14. The Relationship Between Oxygen Reserve Index and Arterial Partial Pressure of Oxygen During Surgery.

    Science.gov (United States)

    Applegate, Richard L; Dorotta, Ihab L; Wells, Briana; Juma, David; Applegate, Patricia M

    2016-09-01

    The use of intraoperative pulse oximetry (SpO2) enhances hypoxia detection and is associated with fewer perioperative hypoxic events. However, SpO2 may be reported as 98% when arterial partial pressure of oxygen (PaO2) is as low as 70 mm Hg. Therefore, SpO2 may not provide advance warning of falling arterial oxygenation until PaO2 approaches this level. Multiwave pulse co-oximetry can provide a calculated oxygen reserve index (ORI) that may add to information from pulse oximetry when SpO2 is >98%. This study evaluates the ORI to PaO2 relationship during surgery. We studied patients undergoing scheduled surgery in which arterial catheterization and intraoperative arterial blood gas analysis were planned. Data from multiple pulse co-oximetry sensors on each patient were continuously collected and stored on a research computer. Regression analysis was used to compare ORI with PaO2 obtained from each arterial blood gas measurement and changes in ORI with changes in PaO2 from sequential measurements. Linear mixed-effects regression models for repeated measures were then used to account for within-subject correlation across the repeatedly measured PaO2 and ORI and for the unequal time intervals of PaO2 determination over elapsed surgical time. Regression plots were inspected for ORI values corresponding to PaO2 of 100 and 150 mm Hg. ORI and PaO2 were compared using mixed-effects models with a subject-specific random intercept. ORI values and PaO2 measurements were obtained from intraoperative data collected from 106 patients. Regression analysis showed that the ORI to PaO2 relationship was stronger for PaO2 to 240 mm Hg (r = 0.536) than for PaO2 over 240 mm Hg (r = 0.0016). Measured PaO2 was ≥100 mm Hg for all ORI over 0.24. Measured PaO2 was ≥150 mm Hg in 96.6% of samples when ORI was over 0.55. A random intercept variance component linear mixed-effects model for repeated measures indicated that PaO2 was significantly related to ORI (β[95% confidence interval] = 0

  15. Evaluation of peripheral microcirculation improvement of foot after tarsal tunnel release in diabetic patients by transcutaneous oximetry.

    Science.gov (United States)

    Trignano, Emilio; Fallico, Nefer; Chen, Hung-Chi; Faenza, Mario; Bolognini, Alfonso; Armenti, Andrea; Santanelli Di Pompeo, Fabio; Rubino, Corrado; Campus, Gian Vittorio

    2016-01-01

    According to recent studies, peripheral nerve decompression in diabetic patients seems to not only improve nerve function, but also to increase microcirculation; thus decreasing the incidence of diabetic foot wounds and amputations. However, while the postoperative improvement of nerve function is demonstrated, the changes in peripheral microcirculation have not been demonstrated yet. The aim of this study is to assess the degree of microcirculation improvement of foot after the tarsal tunnel release in the diabetic patients by using transcutaneous oximetry. Twenty diabetic male patients aged between 43 and 72 years old (mean age 61.2 years old) suffering from diabetic peripheral neuropathy with superimposed nerve compression underwent transcutaneous oximetry (PtcO2) before and after tarsal tunnel release by placing an electrode on the skin at the level of the dorsum of the foot. Eight lower extremities presented diabetic foot wound preoperatively. Thirty-six lower extremities underwent surgical release of the tibialis posterior nerve only, whereas four lower extremities underwent the combined release of common peroneal nerve, anterior tibialis nerve, and posterior tibialis nerve. Preoperative values of transcutaneous oximetry were below the critical threshold, that is, lower than 40 mmHg (29.1 ± 5.4 mmHg). PtcO2 values at one month after surgery (45.8 ± 6.4 mmHg) were significantly higher than the preoperative ones (P = 0.01). The results of postoperative increase in PtcO2 values demonstrate that the release of the tarsal tunnel determines a relevant increase in microcirculation in the feet of diabetic patients. © 2015 Wiley Periodicals, Inc.

  16. Accuracy of noninvasive multiwave pulse oximetry compared with carboxyhemoglobin from blood gas analysis in unselected emergency department patients.

    Science.gov (United States)

    Roth, Dominik; Herkner, Harald; Schreiber, Wolfgang; Hubmann, Nina; Gamper, Gunnar; Laggner, Anton N; Havel, Christof

    2011-07-01

    Accurate and timely diagnosis of carbon monoxide (CO) poisoning is difficult because of nonspecific symptoms. Multiwave pulse oximetry might facilitate the screening for occult poisoning by noninvasive measurement of carboxyhemoglobin (COHb), but its reliability is still unknown. We assess bias and precision of COHb oximetry compared with the criterion standard blood gas analysis. This was a prospective diagnostic accuracy study according to STARD (Standards for the Reporting of Diagnostic accuracy studies) criteria, performed at a tertiary care hospital emergency department. We included all patients for whom both invasive and noninvasive measurement within 60 minutes was available, regardless of their complaints, during a 1-year period. One thousand five hundred seventy-eight subjects were studied, of whom 17 (1.1%) received a diagnosis of CO poisoning. In accordance with this limited patient cohort, we found a bias of 2.99% COHb (1.50% for smokers, 4.33% for nonsmokers) and a precision of 3.27% COHb (2.90% for smokers, 2.98% for nonsmokers), limits of agreement from -3.55% to 9.53% COHb (-4.30% to 7.30% for smokers, -1.63% to 10.29% for nonsmokers). Upper limit of normal cutoff of 6.6% COHb had the highest sensitivity in screening for CO poisoning. Smoking status and COHb level had the most influence on the deviation between measurements. Multiwave pulse oximetry was found to measure COHb with an acceptable bias and precision. These results suggest it can be used to screen large numbers of patients for occult CO poisoning. Copyright © 2011 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  17. Spectral filtering modulation method for estimation of hemoglobin concentration and oxygenation based on a single fluorescence emission spectrum in tissue phantoms.

    Science.gov (United States)

    Liu, Quan; Vo-Dinh, Tuan

    2009-10-01

    Hemoglobin concentration and oxygenation in tissue are important biomarkers that are useful in both research and clinical diagnostics of a wide variety of diseases such as cancer. The authors aim to develop simple ratiometric method based on the spectral filtering modulation (SFM) of fluorescence spectra to estimate the total hemoglobin concentration and oxygenation in tissue using only a single fluorescence emission spectrum, which will eliminate the need of diffuse reflectance measurements and prolonged data processing as required by most current methods, thus enabling rapid clinical measurements. The proposed method consists of two steps. In the first step, the total hemoglobin concentration is determined by comparing a ratio of fluorescence intensities at two emission wavelengths to a calibration curve. The second step is to estimate oxygen saturation by comparing a double ratio that involves three emission wavelengths to another calibration curve that is a function of oxygen saturation for known total hemoglobin concentration. Theoretical derivation shows that the ratio in the first step is linearly proportional to the total hemoglobin concentrations and the double ratio in the second step is related to both total hemoglobin concentration and hemoglobin oxygenation for the chosen fiber-optic probe geometry. Experiments on synthetic fluorescent tissue phantoms, which included hemoglobin with both constant and varying oxygenation as the absorber, polystyrene spheres as scatterers, and flavin adenine dinucleotide as the fluorophore, were carried out to validate the theoretical prediction. Tissue phantom experiments confirm that the ratio in the first step is linearly proportional to the total hemoglobin concentration and the double ratio in the second step is related to both total hemoglobin concentrations and hemoglobin oxygenation. Furthermore, the relations between the two ratios and the total hemoglobin concentration and hemoglobin oxygenation are insensitive

  18. Saturation of the turbulent dynamo.

    Science.gov (United States)

    Schober, J; Schleicher, D R G; Federrath, C; Bovino, S; Klessen, R S

    2015-08-01

    The origin of strong magnetic fields in the Universe can be explained by amplifying weak seed fields via turbulent motions on small spatial scales and subsequently transporting the magnetic energy to larger scales. This process is known as the turbulent dynamo and depends on the properties of turbulence, i.e., on the hydrodynamical Reynolds number and the compressibility of the gas, and on the magnetic diffusivity. While we know the growth rate of the magnetic energy in the linear regime, the saturation level, i.e., the ratio of magnetic energy to turbulent kinetic energy that can be reached, is not known from analytical calculations. In this paper we present a scale-dependent saturation model based on an effective turbulent resistivity which is determined by the turnover time scale of turbulent eddies and the magnetic energy density. The magnetic resistivity increases compared to the Spitzer value and the effective scale on which the magnetic energy spectrum is at its maximum moves to larger spatial scales. This process ends when the peak reaches a characteristic wave number k☆ which is determined by the critical magnetic Reynolds number. The saturation level of the dynamo also depends on the type of turbulence and differs for the limits of large and small magnetic Prandtl numbers Pm. With our model we find saturation levels between 43.8% and 1.3% for Pm≫1 and between 2.43% and 0.135% for Pm≪1, where the higher values refer to incompressible turbulence and the lower ones to highly compressible turbulence.

  19. Criteria for saturated magnetization loop

    International Nuclear Information System (INIS)

    Harres, A.; Mikhov, M.; Skumryev, V.; Andrade, A.M.H. de; Schmidt, J.E.; Geshev, J.

    2016-01-01

    Proper estimation of magnetization curve parameters is vital in studying magnetic systems. In the present article, criteria for discrimination non-saturated (minor) from saturated (major) hysteresis loops are proposed. These employ the analysis of (i) derivatives of both ascending and descending branches of the loop, (ii) remanent magnetization curves, and (iii) thermomagnetic curves. Computational simulations are used in order to demonstrate their validity. Examples illustrating the applicability of these criteria to well-known real systems, namely Fe_3O_4 and Ni fine particles, are provided. We demonstrate that the anisotropy-field value estimated from a visual examination of an only apparently major hysteresis loop could be more than two times lower than the real one. - Highlights: • Proper estimation of hysteresis-loop parameters is vital in magnetic studies. • We propose criteria for discrimination minor from major hysteresis loops. • The criteria analyze magnetization, remanence and ZFC/FC curves and/or their derivatives. • Examples of their application on real nanoparticles systems are given. • Using the criteria could avoid twofold or bigger saturation-field underestimation errors.

  20. Criteria for saturated magnetization loop

    Energy Technology Data Exchange (ETDEWEB)

    Harres, A. [Departamento de Física, UFSM, Santa Maria, 97105-900 Rio Grande do Sul (Brazil); Mikhov, M. [Faculty of Physics, University of Sofia, 1164 Sofia (Bulgaria); Skumryev, V. [Institució Catalana de Recerca i Estudis Avançats, 08010 Barcelona (Spain); Departament de Física, Universitat Autònoma de Barcelona, 08193 Barcelona (Spain); Andrade, A.M.H. de; Schmidt, J.E. [Instituto de Física, UFRGS, Porto Alegre, 91501-970 Rio Grande do Sul (Brazil); Geshev, J., E-mail: julian@if.ufrgs.br [Departament de Física, Universitat Autònoma de Barcelona, 08193 Barcelona (Spain); Instituto de Física, UFRGS, Porto Alegre, 91501-970 Rio Grande do Sul (Brazil)

    2016-03-15

    Proper estimation of magnetization curve parameters is vital in studying magnetic systems. In the present article, criteria for discrimination non-saturated (minor) from saturated (major) hysteresis loops are proposed. These employ the analysis of (i) derivatives of both ascending and descending branches of the loop, (ii) remanent magnetization curves, and (iii) thermomagnetic curves. Computational simulations are used in order to demonstrate their validity. Examples illustrating the applicability of these criteria to well-known real systems, namely Fe{sub 3}O{sub 4} and Ni fine particles, are provided. We demonstrate that the anisotropy-field value estimated from a visual examination of an only apparently major hysteresis loop could be more than two times lower than the real one. - Highlights: • Proper estimation of hysteresis-loop parameters is vital in magnetic studies. • We propose criteria for discrimination minor from major hysteresis loops. • The criteria analyze magnetization, remanence and ZFC/FC curves and/or their derivatives. • Examples of their application on real nanoparticles systems are given. • Using the criteria could avoid twofold or bigger saturation-field underestimation errors.

  1. Muscle tissue saturation in humans studied with two non-invasive optical techniques: a comparative study

    Science.gov (United States)

    Shaharin, Alfi; Krite Svanberg, Emilie; Ellerström, Ida; Subash, Arman Ahamed; Khoptyar, Dmitry; Andersson-Engels, Stefan; Åkeson, Jonas

    2013-11-01

    Muscle tissue saturation (StO2) has been measured with two non-invasive optical techniques and the results were compared. One of the techniques is widely used in the hospitals - the CW-NIRS technique. The other is the photon timeof- flight spectrometer (pTOFS) developed in the Group of Biophotonics, Lund University, Sweden. The wavelengths used in both the techniques are 730 nm and 810 nm. A campaign was arranged to perform measurements on 21 (17 were taken for comparison) healthy adult volunteers (8 women and 13 men). Oxygen saturations were measured at the right lower arm of each volunteer. To observe the effects of different provocations on the oxygen saturation a blood pressure cuff was attached in the upper right arm. For CW-NIRS, the tissue saturation values were in the range from 70-90%, while for pTOFS the values were in the range from 55-60%.

  2. Oxygen Effects in Anaerobic Digestion

    Directory of Open Access Journals (Sweden)

    Deshai Botheju

    2009-10-01

    Full Text Available Interaction of free oxygen in bio-gasification is a sparsely studied area, apart from the common argument of oxygen being toxic and inhibitory for anaerobic micro-cultures. Some studies have, however, revealed increased solubilisation of organic matter in the presence of some free oxygen in anaerobic digestion. This article analyses these counterbalancing phenomena with a mathematical modelling approach using the widely accepted biochemical model ADM 1. Aerobic oxidation of soluble carbon and inhibition of obligatory anaerobic organisms are modelled using standard saturation type kinetics. Biomass dependent first order hydrolysis kinetics is used to relate the increased hydrolysis rate with oxygen induced increase in biomass growth. The amended model, ADM 1-Ox (oxygen, has 25 state variables and 22 biochemical processes, presented in matrix form. The computer aided simulation tool AQUASIM 2.1 is used to simulate the developed model. Simulation predictions are evaluated against experimental data obtained using a laboratory batch test array comprising miniature anaerobic bio-reactors of 100 ml total volume each, operated under different initial air headspaces giving rise to the different oxygen loading conditions. The reactors were initially fed with a glucose solution and incubated at 35 Celsius, for 563 hours. Under the oxygen load conditions of 22, 44 and 88 mg/L, the ADM1-Ox model simulations predicted the experimental methane potentials quite adequately. Both the experimental data and the simulations suggest a linear reduction of methane potential with respect to the increase in oxygen load within this range.

  3. Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry

    NARCIS (Netherlands)

    Nijland, R.; Jongsma, H.W.; Nijhuis, J.G.; Oeseburg, Berend; Zijlstra, Willem

    1995-01-01

    Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible

  4. Effect of oxygen treatment on heart rate after abdominal surgery

    DEFF Research Database (Denmark)

    Rosenberg-Adamsen, S; Lie, C; Bernhard, A

    1999-01-01

    BACKGROUND: Cardiac complications are common during the postoperative period and may be associated with hypoxemia and tachycardia. Preliminary studies in high-risk patients after operation have shown a possible beneficial effect of oxygen therapy on arterial oxygen saturation and heart rate....... METHODS: The authors studied the effect of oxygen therapy on arterial oxygen saturation and heart rate in 100 consecutive unselected patients randomly and double blindly allocated to receive air or oxygen therapy between the first and fourth day after major abdominal surgery. RESULTS: The median arterial...... oxygen saturation rate increased significantly from 96% to 99% (P heart rate decreased significantly from 85 beats/min to 81 beats/min (P heart rate occurred...

  5. Observability of linear systems with saturated outputs

    NARCIS (Netherlands)

    Koplon, R.; Sontag, E.D.; Hautus, M.L.J.

    1994-01-01

    We present necessary and sufficient conditions for observability of the class of output-saturated systems. These are linear systems whose output passes through a saturation function before it can be measured.

  6. Fault tolerant control of systems with saturations

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik

    2013-01-01

    This paper presents framework for fault tolerant controllers (FTC) that includes input saturation. The controller architecture known from FTC is based on the Youla-Jabr-Bongiorno-Kucera (YJBK) parameterization is extended to handle input saturation. Applying this controller architecture in connec......This paper presents framework for fault tolerant controllers (FTC) that includes input saturation. The controller architecture known from FTC is based on the Youla-Jabr-Bongiorno-Kucera (YJBK) parameterization is extended to handle input saturation. Applying this controller architecture...... in connection with faulty systems including input saturation gives an additional YJBK transfer function related to the input saturation. In the fault free case, this additional YJBK transfer function can be applied directly for optimizing the feedback loop around the input saturation. In the faulty case......, the design problem is a mixed design problem involved both parametric faults and input saturation....

  7. PULSE OXIMETRY AS A POTENTIAL SCREENING TOOL FOR LOWER EXTREMITY ARTERIAL DISEASE IN ASYMPTOMATIC PATIENTS WITH DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Sankaran Nair Kailasanadhan

    2018-02-01

    Full Text Available BACKGROUND India, with a population greater than 1.1 billion, has the dubious distinction of having a larger number of people with diabetes than any other country in the world. It was estimated in the year. 2000 that there are 32 million diabetes patients. Diabetic foot ulcers will complicate the disease in more than 15% of these people during their life time. Foot ulcers precede more than 80% of non-traumatic lower limb amputation. Individuals with diabetes had a tenfold higher overall amputation prevalence than did people without diabetes, 2.8% versus 0.29%. MATERIALS AND METHODS A Cross sectional study was done in the department of general surgery, Government Medical College Kottayam and Diabetic Clinic, Kottayam Medical College, from April 1, 2013 to October 1, 2013. RESULTS Out of 150 patients studied 83 were males and 67 were females and 95 patients (63.3% had POVD Statically significant association was found between POVD and age, history of hypertension, hyperlipidaemia, smoking, alcoholism, duration of diabetes mellitus and family history of hypertension/diabetes and hyperlipidaemia. Sensitivity and specificity of Pulse Oximetry in diagnosing POVD is 80% and 92.7% respectively. Sensitivity and specificity of ABPI in diagnosing POVD is 77.9% and 89.1% respectively. CONCLUSION Pulse Oximetry is an accurate and efficient screening tool for POVD in patients with diabetes mellitus. It can be incorporated to regular outpatient visits of Diabetes patients for early detection of POVD.

  8. Empirical algorithms to predict aragonite saturation state

    Science.gov (United States)

    Turk, Daniela; Dowd, Michael

    2017-04-01

    Novel sensor packages deployed on autonomous platforms (Profiling Floats, Gliders, Moorings, SeaCycler) and biogeochemical models have a potential to increase the coverage of a key water chemistry variable, aragonite saturation state (ΩAr) in time and space, in particular in the under sampled regions of global ocean. However, these do not provide the set of inorganic carbon measurements commonly used to derive ΩAr. There is therefore a need to develop regional predictive models to determine ΩAr from measurements of commonly observed or/and non carbonate oceanic variables. Here, we investigate predictive skill of several commonly observed oceanographic variables (temperature, salinity, oxygen, nitrate, phosphate and silicate) in determining ΩAr using climatology and shipboard data. This will allow us to assess potential for autonomous sensors and biogeochemical models to monitor ΩAr regionally and globally. We apply the regression models to several time series data sets and discuss regional differences and their implications for global estimates of ΩAr.

  9. Low-cost but accurate radioactive logging for determining gas saturation in a reservior

    International Nuclear Information System (INIS)

    Neuman, C.H.

    1976-01-01

    A method is disclosed for determining gas saturation in a petroleum reservoir using logging signals indirectly related to the abundances of oxygen and carbon nuclei in the reservoir rock. The first step of the invention is to record first and second logs sensitive to the abundance of oxygen and carbon nuclei, respectively, after the region surrounding the well bore is caused to have fluid saturations representative of the bulk of the reservoir. A purposeful change is then made in the fluid saturations in the region surrounding the well bore by injecting a liquid capable of displacing substantially all of the original fluids. The logs are recorded a second time. The displacing fluid is then itself displaced by brine, and a third suite of logs is recorded. The total fluid and oil saturations are then determined from the differences between respective corresponding logs and from known fractional volume oxygen and carbon contents of the reservoir brine and oil and the first injected liquid. Gas saturation is then calculated from differences between total fluid and oil saturation values. It is not necessary that the log responses be independent of the material in the borehole, the casing, the casing cement, or the reservoir rock. It is only necessary that changes in formation fluids content cause proportional changes in log responses. 7 Claims, 4 Figures

  10. Receptor saturation in roentgen films

    Energy Technology Data Exchange (ETDEWEB)

    Strid, K G; Reichmann, S [Sahlgrenska Sjukhuset, Goeteborg (Sweden)

    1980-01-01

    Roentgen-film recording of small object details of low attenuation differences (e.g. pulmonary vessels) is regularl