WorldWideScience

Sample records for oxime lung scintigraphy

  1. Lung scintigraphy

    International Nuclear Information System (INIS)

    Dalenz, Roberto.

    1994-01-01

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies

  2. Lung scintigraphy; Centellograma pulmonar

    Energy Technology Data Exchange (ETDEWEB)

    Dalenz, Roberto

    1994-12-31

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies.

  3. Lung inhalation scintigraphy with radioactive aerosols in several pulmonary diseases

    International Nuclear Information System (INIS)

    Martins, L.R.; Marioni Filho, H.; Romaldini, H.; Uehara, C.; Alonso, G.

    1983-01-01

    The pulmonary ventilation scintigraphy with 99m Tc diethylene-triamine-pentaacetate (99mTc-DTPA) delivered through a new nebulizer system when analyzed together with the classic lung perfusion scintigraphy with 99mTc-labeled albumin macroaggregates (99mTcMAA) is a very important diagnostic tool in several pulmonary diseases. Several aspects of the lung ventilation-perfusion scintigraphy are studied in 15 people with no lung disease, smokers and nonsmokers. The findings with the lung ventilation-perfusion scintigraphy are also discussed in 34 patients with several pulmonary diseases: lung cancer, chronic obstructive lung disease, policystic pulmonary disease, and pulmonary embolims. The authors concluded that the procedure is a valuable diagnostic tool in several pulmonary diseases, especially because good lung images are obtained, no side effects were detected, the technique is ease and low cost, and it brings new informations, not available with other diagnostic methods. (author)

  4. Lung perfusion scintigraphy by SPECT

    International Nuclear Information System (INIS)

    Hirayama, Takanobu

    1990-01-01

    The initial study reports the characteristic performance using lung segmental phantom filled in Tc-99m pertechnetate. To evaluate the segmental defect in lung perfusion scintigraphy, we applied Bull's-eye analysis in addition to planar image set. Bull's-eye analysis especially facilitated the interpretation in both middle and lower lobes. Subsequently, to evolute the clinical application of Bull's-eye analysis, pulmonary scintigraphy was performed on 10 normal subjects and 60 patients with several pulmonary diseases. Of interest, Bull's-eye analysis, however, encouraged the interpretation in both lower lobes. To calculate the extention and severity of perfusion defect, the present study describes Bull's-eye analysis. Quantitative scoring showed higher in patients with lung cancer than those with pulmonary tuberculosis. The present study focus that Bull's-eye analysis can be useful for evaluating perfusion in patients with a couple of pulmonary diseases. (author)

  5. Radioaerosol lung scintigraphy in idiopathic scolios

    International Nuclear Information System (INIS)

    Maini, C.L.; Giordano, A.; Santucci, B.; Aulisa, L.; Pistelli, R.; Fuso, L.

    1988-01-01

    The study of respiratory fuctions is of key importance for the clinical evaluation of patients with idiopathic scoliosis. Such study has been traditionally based on classical pulmonary function tests and arterial hemogasanalysis. However, neither procedure gives any information on the topographical distribution of abnormalities, and both might be suboptimal as far as sensitivity is concerned. The preliminary results obtained with radioaerosol lung scintigraphy in 11 patients with scoliosis are here presented. They lead to the conclusion that radioaerosol lung scintigraphy, besides being an useful adjunct to more traditional diagnostic procedures, can yield unique information on the localization of convective ventilation derangements induced by the dynamic abnormalities of the rib cage

  6. [Lung scintigraphy].

    Science.gov (United States)

    Schümichen, Carl; Schmidt, Matthias; Krause, Thomas

    2018-06-01

    The S1 guideline for lung scintigraphy has been updated and extended in order to emphasize the advantages oft the method in detecting acute pulmonary embolism (PE) in the periphery oft the lung (subsegmental PE), in underlying subacute and chronic pulmonary disorders, as well as in detecting chronic LE (CTEPH). Method of choice is ventilation / perfusion (V/P) SPECT or V/P SPECT/CT with even higher specificity. Because of its high sensitivity, a threshold (V/P mismatch in at least one segment or two subsegments) is introduced to avoid overtreatment. In case of a change in the therapeutic approach (observation only instead of anticoaculation) the threshold can be omitted. New data concerning the clinical and therapeutical impact of subsegmental PE are included, the chapters open questions have been extented. Other indications for V/P SPECT (secondary diagnoses, abnormalities in pulmonary perfusion, prediction of postoperative lung function) are presented with new data. Schattauer GmbH.

  7. Lung scintigraphy in differential diagnosis of peripheral lung cancer and community-acquired pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Krivonogov, Nikolay G., E-mail: kng@cardio-tomsk.ru [Research Institute of Cardiology, Kievskaya Street 111a, Tomsk, 634012 (Russian Federation); Efimova, Nataliya Y., E-mail: efimova@cardio-tomsk.ru; Zavadovsky, Konstantin W.; Lishmanov, Yuri B. [Research Institute of Cardiology, Kievskaya Street 111a, Tomsk, 634012 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation)

    2016-08-02

    Ventilation/perfusion lung scintigraphy was performed in 39 patients with verified diagnosis of community-acquired pneumonia (CAP) and in 14 patients with peripheral lung cancer. Ventilation/perfusion ratio, apical-basal gradients of ventilation (U/L(V)) and lung perfusion (U/L(P)), and alveolar capillary permeability of radionuclide aerosol were determined based on scintigraphy data. The study demonstrated that main signs of CAP were increases in ventilation/perfusion ratio, perfusion and ventilation gradient on a side of the diseased lung, and two-side increase in alveolar capillary permeability rate for radionuclide aerosol. Unlike this, scintigraphic signs of peripheral lung cancer comprise an increase in ventilation/perfusion ratio over 1.0 on a side of the diseased lung with its simultaneous decrease on a contralateral side, normal values of perfusion and ventilation gradients of both lungs, and delayed alveolar capillary clearance in the diseased lung compared with the intact lung.

  8. Lung scintigraphy in differential diagnosis of peripheral lung cancer and community-acquired pneumonia

    Science.gov (United States)

    Krivonogov, Nikolay G.; Efimova, Nataliya Y.; Zavadovsky, Konstantin W.; Lishmanov, Yuri B.

    2016-08-01

    Ventilation/perfusion lung scintigraphy was performed in 39 patients with verified diagnosis of community-acquired pneumonia (CAP) and in 14 patients with peripheral lung cancer. Ventilation/perfusion ratio, apical-basal gradients of ventilation (U/L(V)) and lung perfusion (U/L(P)), and alveolar capillary permeability of radionuclide aerosol were determined based on scintigraphy data. The study demonstrated that main signs of CAP were increases in ventilation/perfusion ratio, perfusion and ventilation gradient on a side of the diseased lung, and two-side increase in alveolar capillary permeability rate for radionuclide aerosol. Unlike this, scintigraphic signs of peripheral lung cancer comprise an increase in ventilation/perfusion ratio over 1.0 on a side of the diseased lung with its simultaneous decrease on a contralateral side, normal values of perfusion and ventilation gradients of both lungs, and delayed alveolar capillary clearance in the diseased lung compared with the intact lung.

  9. Improving the diagnostic performance of lung scintigraphy in suspected pulmonary embolic disease

    International Nuclear Information System (INIS)

    Gleeson, F.V.; Turner, S.; Scarsbrook, A.F.

    2006-01-01

    Aim: to determine the effectiveness of a new imaging algorithm in the investigation of suspected pulmonary embolism (PE). Materials and methods: A new imaging algorithm for suspected PE was introduced following the installation of a multisection computed tomography (CT) machine at our institution. Before its installation, patients with suspected PE were evaluated with ventilation/perfusion (V/Q) scintigraphy. Subsequently, patients were triaged according to chest radiography (CR) and respiratory history to either lung scintigraphy or CT pulmonary angiography (CTPA). Patients with a normal CR and no history of lung disease were evaluated using perfusion (Q) scintigraphy [ventilation (V) scintigraphy was no longer performed]. Patients with an abnormal CR, asthma or chronic lung disease were evaluated using CTPA. All V/Q images in a continuous 3-year period before the introduction of the new imaging algorithm and all Q images performed in a 3-year period after its introduction were retrospectively reviewed. Imaging reports were categorized into normal, non-diagnostic (low or intermediate probability) or high probability for PE. Patients in the later group who subsequently underwent CTPA, were also reviewed. Results: After the policy change the percentage of normal scintigrams significantly increased (39 to 60%; p < 0.001). There was a non-significant increase in the percentage of high probability scintigrams (15 to 18%; p = 0.716). Overall the diagnostic yield of lung scintigraphy improved significantly (54 to 78%; p < 0.001). Conclusion: the diagnostic performance of lung scintigraphy can be improved by careful triage of patients to either Q scintigraphy or CTPA based on clinical history and CR findings. Q scintigraphy remains a valuable diagnostic test in the investigation of suspected PE in carefully selected patients

  10. Aerosol lung inhalation scintigraphy in normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Sui, Osamu; Shimazu, Hideki

    1985-03-01

    We previously reported basic and clinical evaluation of aerosol lung inhalation scintigraphy with /sup 99m/Tc-millimicrosphere albumin (milli MISA) and concluded aerosol inhalation scintigraphy with /sup 99m/Tc-milli MISA was useful for routine examination. But central airway deposit of aerosol particles was found in not only the patients with chronic obstructive pulmonary disease (COPD) but also normal subjects. So we performed aerosol inhalation scintigraphy in normal subjects and evaluated their scintigrams. The subjects had normal values of FEVsub(1.0)% (more than 70%) in lung function tests, no abnormal findings in chest X-ray films and no symptoms and signs. The findings of aerosol inhalation scintigrams in them were classified into 3 patterns; type I: homogeneous distribution without central airway deposit, type II: homogeneous distribution with central airway deposit, type III: inhomogeneous distribution. These patterns were compared with lung function tests. There was no significant correlation between type I and type II in lung function tests. Type III was different from type I and type II in inhomogeneous distribution. This finding showed no correlation with %VC, FEVsub(1.0)%, MMF, V radical50 and V radical50/V radical25, but good correlation with V radical25 in a maximum forced expiratory flow-volume curve. Flow-volume curve is one of the sensitive methods in early detection of COPD, so inhomogeneous distribution of type III is considered to be due to small airway dysfunction.

  11. Contribution of technetium-99m hexamethylpropylene amine oxime labelled leucocyte scintigraphy to the diagnosis of diabetic foot infection

    International Nuclear Information System (INIS)

    Devillers, A.; Moisan, A.; Garin, E.; Bourguet, P.; Hennion, F.; Poirier, J.Y.

    1998-01-01

    We conducted a prospective study in order to evaluate the contribution of technetium-99m hexamethylpropylene amine oxime (HMPAO) labelled leucocyte scintigraphy to the diagnosis and follow-up of osteomyelitis in the diabetic foot. The study was conducted between October 1992 and November 1996 and included 42 patients (30 men and 12 women; mean age 63 years) with diabetes mellitus (type 1, n = 22, type 2, n = 20) who had a total of 56 diabetic foot ulcers. The initial exploration included standard radiography, three-phase bone scintigraphy and 99m Tc-HMPAO labelled leucocyte scintigraphy (HMPAO-LS), performed within a 3-day interval. For the 56 ulceration sites, 26 cases of osteomyelitis were diagnosed: ten on the basis of radiographic and histological/bacteriological criteria after bone biopsy, 11 after radiographic follow-up and five on the basis of biopsy results alone. No osteomyelitis was present at 30 sites, there were seven cases of cellulitis. The sensitivity and specificity of 99m Tc-HMPAO-LS were 88.4% and 96.6% respectively (23 true-positives, 29 true-negatives, one false-positive, three false-negatives). The accuracy of radiography, 99m Tc-methylene diphosphonate and HMPAO-LS was 69.6%, 62.5%, and 92.9%, respectively. Follow-up scintigraphy (n = 14) 4 months after initial diagnosis and 1 month after antibiotic withdrawal confirmed cure of osteomyelitis despite the absence of complete clinical regression of the ulcers. In conclusion, 99m Tc-HMPAO labelled leucocyte scintigraphy was found to be an excellent method for the diagnosis of osteomyelitis in the diabetic foot. It can contribute to follow-up, particularly when clinical regression of perforating ulcers is incomplete and cure of osteomyelitis must be confirmed in order that antibiotic treatment may be discontinued. (orig.)

  12. Contribution of technetium-99m hexamethylpropylene amine oxime labelled leucocyte scintigraphy to the diagnosis of diabetic foot infection

    Energy Technology Data Exchange (ETDEWEB)

    Devillers, A.; Moisan, A.; Garin, E.; Bourguet, P. [CRLCC Eugene Marquis, Service de Medecine Nucleaire, Rennes (France); Hennion, F.; Poirier, J.Y. [CHRU Pontchaillou, Service d`Endocrinologie, Rennes (France)

    1998-02-01

    We conducted a prospective study in order to evaluate the contribution of technetium-99m hexamethylpropylene amine oxime (HMPAO) labelled leucocyte scintigraphy to the diagnosis and follow-up of osteomyelitis in the diabetic foot. The study was conducted between October 1992 and November 1996 and included 42 patients (30 men and 12 women; mean age 63 years) with diabetes mellitus (type 1, n = 22, type 2, n = 20) who had a total of 56 diabetic foot ulcers. The initial exploration included standard radiography, three-phase bone scintigraphy and {sup 99m}Tc-HMPAO labelled leucocyte scintigraphy (HMPAO-LS), performed within a 3-day interval. For the 56 ulceration sites, 26 cases of osteomyelitis were diagnosed: ten on the basis of radiographic and histological/bacteriological criteria after bone biopsy, 11 after radiographic follow-up and five on the basis of biopsy results alone. No osteomyelitis was present at 30 sites, there were seven cases of cellulitis. The sensitivity and specificity of {sup 99m}Tc-HMPAO-LS were 88.4% and 96.6% respectively (23 true-positives, 29 true-negatives, one false-positive, three false-negatives). The accuracy of radiography, {sup 99m}Tc-methylene diphosphonate and HMPAO-LS was 69.6%, 62.5%, and 92.9%, respectively. Follow-up scintigraphy (n = 14) 4 months after initial diagnosis and 1 month after antibiotic withdrawal confirmed cure of osteomyelitis despite the absence of complete clinical regression of the ulcers. In conclusion, {sup 99m}Tc-HMPAO labelled leucocyte scintigraphy was found to be an excellent method for the diagnosis of osteomyelitis in the diabetic foot. It can contribute to follow-up, particularly when clinical regression of perforating ulcers is incomplete and cure of osteomyelitis must be confirmed in order that antibiotic treatment may be discontinued. (orig.) With 5 figs., 3 tabs., 28 refs.

  13. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Y.; Hayashida, K.; Uehara, T.; Shimonagata, T.; Nishimura, T.; Osaka Univ., Suita

    1993-01-01

    15 cases of primary pulmonary hypertension were classified into two groups by patterns of perfusion lung scintigraphy. Perfusion scintigrams showed multiple, small, ill-defined defects (mottled + ve) pattern in eight cases, and the remaining seven cases had a normal (mottled - ve) pattern. The mean pulmonary arterial pressure in patients with a mottled pattern (54 ± 10 mmHg) was higher than in those with a normal pattern (42 ± 9 mmHg, p < 0.05). There were no significant differences between the two groups in right ventricular ejection fraction, partial pressures of oxygen in the arterial blood or alveolo-arterial oxygen difference. All the patients with a mottled pattern died within 2 years following the lung scintigraphy. There was a significant difference in the survival curves between the two groups. (author)

  14. Pulmonary embolism in pregnancy: comparison of pulmonary CT angiography and lung scintigraphy.

    LENUS (Irish Health Repository)

    Ridge, Carole A

    2012-02-01

    OBJECTIVE: The purpose of this study was to retrospectively compare the diagnostic adequacy of lung scintigraphy with that of pulmonary CT angiography (CTA) in the care of pregnant patients with suspected pulmonary embolism. MATERIALS AND METHODS: Patient characteristics, radiology report content, additional imaging performed, final diagnosis, and diagnostic adequacy were recorded for pregnant patients consecutively referred for lung scintigraphy or pulmonary CTA according to physician preference. Measurements of pulmonary arterial enhancement were performed on all pulmonary CTA images of pregnant patients. Lung scintigraphy and pulmonary CTA studies deemed inadequate for diagnosis at the time of image acquisition were further assessed, and the cause of diagnostic inadequacy was determined. The relative contribution of the inferior vena cava to the right side of the heart was measured on nondiagnostic CTA images and compared with that on CTA images of age-matched nonpregnant women, who were the controls. RESULTS: Twenty-eight pulmonary CTA examinations were performed on 25 pregnant patients, and 25 lung scintigraphic studies were performed on 25 pregnant patients. Lung scintigraphy was more frequently adequate for diagnosis than was pulmonary CTA (4% vs 35.7%) (p = 0.0058). Pulmonary CTA had a higher diagnostic inadequacy rate among pregnant than nonpregnant women (35.7% vs 2.1%) (p < 0.001). Transient interruption of contrast material by unopacified blood from the inferior vena cava was identified in eight of 10 nondiagnostic pulmonary CTA studies. CONCLUSION: We found that lung scintigraphy was more reliable than pulmonary CTA in pregnant patients. Transient interruption of contrast material by unopacified blood from the inferior vena cava is a common finding at pulmonary CTA of pregnant patients.

  15. Clinical evaluation of lung rest/stress perfusion scintigraphy in patients with severe emphysema

    International Nuclear Information System (INIS)

    Hadjikostova, Hr.

    1998-01-01

    Volume lung reduction surgery (LVRS) improves lung function and physical tolerance for selected patients with severe pulmonary emphysema by making conditions for developing of the vital parenchyma so far compressed by the emphysema blisters. The aim of this study was to establish the comparative functional information obtained from REST/STRESS lung perfusion tomoscintigraphies for identification of non functional lung tissue. Eleven patients (8 males and 3 females at age 41-60) were examined by two lung perfusions SPECT scintigraphies after intravenous application of 222 MBq 99m Tc-MAA: 1. after 30 min. lying rest and 2. 48 hours later after 6 min. walk test. Comparing the two scintigraphies the following changes in perfusion performance have been established at STRESS examination: increased at six patients (significant at three and slight also at three) and decreased at two. There was no difference between REST and STRESS examinations at 3 patients. Comparative REST/STRESS lung perfusion scintigraphy is important method for screening severe pulmonary patients for LVRS. (author)

  16. Effectiveness of Tc-99m MIBI scintigraphy in diagnosing lung cancer

    International Nuclear Information System (INIS)

    Tanaka, Shigebumi; Asao, Takayuki; Ubukata, Mikio; Sugiyama, Hiroyuki; Yajima, Yasumi; Takenoshita, Seiichi; Nagamachi, Yukio

    1997-01-01

    The use of Tc-99m hexakis 2-methoxy isobutyl isonitrile (MIBI) scintigraphy for quantitative diagnosis was examined. A total of 37 lesions from 31 patients with respiratory disease (19 lesions from 19 primary lung cancer patients, 8 lesions from 3 metastatic lung cancer patients and 10 lesions from benign lung disease patients) were examined. Positive results were seen in 89.4% of the primary lung cancer lesions, 50.0% of the metastatic lung cancer lesions, and 20.0% of the benign lung disease lesions. The positive rate of 77.7% for malignant lung cancer was significantly higher (P<0.01) than that for benign lung cancer. In particular, for lesions with a tumor diameter of 1.0 cm or more, the positive rate for malignant lung cancer lesions (95.2%) was significantly higher (P<0.001) than that for benign lung disease lesions (25.0%). These results thus indicate Tc-99m MIBI scintigraphy to be useful for qualitative diagnosis of lung peripheral coin lesions with a diameter of 1.0 cm or more. (author)

  17. Lung scintigraphy and helical computed tomography for the diagnosis of pulmonary embolism : A meta-analysis

    NARCIS (Netherlands)

    van Beek, EJR; Brouwers, Elise M J; Song, B; Bongaerts, AHH; Oudkerk, M

    To assess the diagnostic value of lung scintigraphy and helical computed tomography (hCT) in patients with suspected pulmonary embolism (PE), all English-language articles that described lung scintigraphy and hCT in patients with suspected PE were retrieved. Articles were assessed for strength of

  18. Perfusion lung scintigraphy in primary broncho-pulmonary cancer

    International Nuclear Information System (INIS)

    Lapergue, Paul.

    1976-01-01

    Research on primary broncho-pulmonary cancer has called extensively on scintigraphy and it seemed interesting to weigh up the pros and cons of the technique in this particular case. Our intention is to sum up objectively from recent documents the applications of scintigraphy in the study of primary broncho-pulmonary cancers and to attempt, on the basis of the results compiled, to show what benefits have been gained from this technique and to find out whether it has any pre-surgical value and of what kind. The technique was invariable; the tracer consists of human albumin macro-aggregates labelled with technetium 99m which by its short half-life and slight penetration enables four exposures to be taken during the same examination (front, back, right and left profiles), thus reducing the risks of mistaken diagnoses due to the use of a single incidence. Similarly the detection method was always the scintillation camera which explores the whole organ at once, considerably shortening the examination time. Lung scintigraphy by perfusion of labelled human albumin macro-aggregates offers the great advantage of being simple to use and harmless. It is easy to understand the important place it has taken in the range of methods available for lung circulation exploration [fr

  19. The value of lung scintigraphy in the diagnosis of pulmonary embolism

    NARCIS (Netherlands)

    van Beek, E. J.; Tiel-van Buul, M. M.; Büller, H. R.; van Royen, E. A.; ten Cate, J. W.

    1993-01-01

    The role of lung scintigraphy in the diagnostic management of patients with clinically suspected pulmonary embolism is reviewed. Evidence is provided that a normal perfusion scan excludes clinically relevant pulmonary embolism, and that a high probability lung scan, defined as a segmental perfusion

  20. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  1. Delayed lung scintigraphy with N-isopropyl-I-123-p-iodoamphetamine in lung cancer and inflammatory disease

    Energy Technology Data Exchange (ETDEWEB)

    Suematsu, Toru; Narabayashi, Isamu; Takada, Yoshiki and others

    1989-01-01

    Lung studies with N-Isopropyl-I-123-p-Iodoamphetamine (IMP) were performed on patients with lung cancer or inflammatory disease. In the present study, we evaluated the usefulness of the delayed scintigraphy. The subjects consisted of 27 patients with lung cancer (34 lesions), 3 with radiation pneumonitis, 2 with interstitial pneumonitis, 2 with old tuberculous lesion (tuberculomas), 1 with diffuse panbronchiolitis, 1 with pneumonia and 1 with lung abscess. The delayed scintigraphy was performed 24 hr after intravenous injection of 3 mCi IMP, in sitting position. In 10 patients, SPECT images were obtained following the delayed scintigraphy. Delayed scintigraphic appearances of lung cancer were classified into 5 types, high IMP uptake in the area congruent with the lesion of atelectasis and/or obstructive pneumonia (Type I), high IMP uptake in the area surrounded the tumor (Type II), a defect in the area consistent with the tumor and no high IMP uptake in the area surrounded the tumor (Type III), high IMP uptake in the area almost congruent with the tumor (Type IV) and no significant change (Type V). Excluding 10 lesions with Type IV or V, no IMP uptake was seen in the areas congruent with the tumors. Type II was the most frequently observed pattern. Normal scintigrams (Type V) were observed in 8 lesions, whose sizes were fairly small. There was no definite trend caused by difference in histological types of cancers. In 8 patients with viable inflammatory disease of the lung, the delayed scintigrams showed high IMP uptake in the areas congruent with the abnormalities on chest roentgenograms. On the other hand, no uptake was seen in the old tuberculous lesions. (J.P.N.).

  2. Delayed lung scintigraphy with N-isopropyl-I-123-p-iodoamphetamine in lung cancer and inflammatory disease

    International Nuclear Information System (INIS)

    Suematsu, Toru; Narabayashi, Isamu; Takada, Yoshiki

    1989-01-01

    Lung studies with N-Isopropyl-I-123-p-Iodoamphetamine (IMP) were performed on patients with lung cancer or inflammatory disease. In the present study, we evaluated the usefulness of the delayed scintigraphy. The subjects consisted of 27 patients with lung cancer (34 lesions), 3 with radiation pneumonitis, 2 with interstitial pneumonitis, 2 with old tuberculous lesion (tuberculomas), 1 with diffuse panbronchiolitis, 1 with pneumonia and 1 with lung abscess. The delayed scintigraphy was performed 24 hr after intravenous injection of 3 mCi IMP, in sitting position. In 10 patients, SPECT images were obtained following the delayed scintigraphy. Delayed scintigraphic appearances of lung cancer were classified into 5 types, high IMP uptake in the area congruent with the lesion of atelectasis and/or obstructive pneumonia (Type I), high IMP uptake in the area surrounded the tumor (Type II), a defect in the area consistent with the tumor and no high IMP uptake in the area surrounded the tumor (Type III), high IMP uptake in the area almost congruent with the tumor (Type IV) and no significant change (Type V). Excluding 10 lesions with Type IV or V, no IMP uptake was seen in the areas congruent with the tumors. Type II was the most frequently observed pattern. Normal scintigrams (Type V) were observed in 8 lesions, whose sizes were fairly small. There was no definite trend caused by difference in histological types of cancers. In 8 patients with viable inflammatory disease of the lung, the delayed scintigrams showed high IMP uptake in the areas congruent with the abnormalities on chest roentgenograms. On the other hand, no uptake was seen in the old tuberculous lesions. (J.P.N.)

  3. Lung inhalation scintigraphy with radioactive aerosols in several pulmonary diseases. Cintigrafia de ventialacao pulmonar por aerosol em diversas patologias pulmonares

    Energy Technology Data Exchange (ETDEWEB)

    Martins, L R; Marioni Filho, H [Instituto Dante Pazzanese de Cardiologia, Sao Paulo, SP (Brazil); Romaldini, H; Uehara, C; Alonso, G [Escola Paulista de Medicina, Sao Paulo, SP (Brazil)

    1983-01-01

    The pulmonary ventilation scintigraphy with 99m Tc diethylene-triamine-pentaacetate (99mTc-DTPA) delivered through a new nebulizer system when analyzed together with the classic lung perfusion scintigraphy with 99mTc-labeled albumin macroaggregates (99mTcMAA) is a very important diagnostic tool in several pulmonary diseases. Several aspects of the lung ventilation-perfusion scintigraphy are studied in 15 people with no lung disease, smokers and nonsmokers. The findings with the lung ventilation-perfusion scintigraphy are also discussed in 34 patients with several pulmonary diseases: lung cancer, chronic obstructive lung disease, policystic pulmonary disease, and pulmonary embolims. The authors concluded that the procedure is a valuable diagnostic tool in several pulmonary diseases, especially because good lung images are obtained, no side effects were detected, the technique is ease and low cost, and it brings new informations, not available with other diagnostic methods. (author).

  4. Usefulness of pulmonary scintigraphy in primary lung cancer patients treated by radiotherapy

    International Nuclear Information System (INIS)

    Mitomo, Osamu

    1994-01-01

    To assess the pulmonary function of lung cancer patients treated by radiotherapy, we tried qualitative and semiquantitative analysis of pulmonary scintigrams using 133 Xe and 99m Tc-MAA. Individual scores for ventilation, perfusion and the ventilation-perfusion ratio of tumor-bearing lungs were calculated on the basis of healthy control cases in order to analyze whether, and to what degree, the tumor-bearing lung was functionally impaired. The score was proportional to the severity of impairment, and when the ventilation and perfusion of tumor-bearing lungs had a score of one or greater than one, the tumor-bearing lung was functionally defined as an 'impaired lung'. Impaired lungs were demonstrated in 68% of tumor-bearing lungs. Hilar and left hilar-type cancers, clinically more advanced cancers, patients whose tumors were confirmed by bronchofiberscopy, small-cell and epidermoid cancers, etc., had higher rates of impairment and more severe impairment. Many patients with impaired lungs had a worse prognosis, but patients in whom scintigraphy showed improvement after radiotherapy had a better prognosis. It can be concluded that pulmonary scintigraphy scoring is capable of semiquantitatively indicating the degree of pulmonary impairment and is useful in deciding on a radiotherapeutic plan and predicting the outcome in pre- and post-radiotherapy lung cancer patients. (author)

  5. The diagnostic application of Ga-67 scintigraphy in primary lung cancer, hepatoma and abdominal abscess

    International Nuclear Information System (INIS)

    Oshiumi, Yoshihiko

    1983-01-01

    It is difficult to detect tumor lesions by 67 Gascintigraphy, though it is named as a tumor scintigraphy. Recently, 67 Ga-scintigraphy is well used in the detection of inflammatic lesions. This paper is to discuss the detectability of lesions and diagnostic limitation on operability by 67 Ga-scintigraphy to primary lung cancer, minute hepatoma and abdominal absccess. Primary lung cancer: In detecting metastatic hilar lymph nodes, the sensitivity is 54%, and the specificity is 78%. In detecting metastatic mediastinal lymph nodes, the sensitivity is 32% and the specificity is 89%. Minute hepatoma : The detectability depended on the size of the lesion. It is hard to detect lesions with under 2 cm by 67 Ga-scintigraphy. Abdominal abscess : The sensitivity is 88%, and the specificity is 92%. (author)

  6. Effect of Garlic on Perfusion Scintigraphy of Rabbit's Lungs ...

    African Journals Online (AJOL)

    Purpose: To study of the effect of garlic on rabbit's lungs, with the aid of perfusion scintigraphy, after experimentally-induced pulmonary embolism. Methods: Twelve adult rabbits were anesthetized. Prepared macroaggregated albumin- technetium 99m (99mTc-MAA) radiopharmaceutical was injected into the ear vein at a ...

  7. Diagnostic application of Ga-67 scintigraphy in primary lung cancer, hepatoma and abdominal abscess. On surgical operation

    Energy Technology Data Exchange (ETDEWEB)

    Oshiumi, Yoshihiko (National Central Hospital of Fukuoka (Japan))

    1983-05-01

    It is difficult to detect tumor lesions by /sup 67/Ga-scintigraphy, though it is named as a tumor scintigraphy. Recently, /sup 67/Ga-scintigraphy is well used in the detection of inflammatic lesions. This paper is to discuss the detectability of lesions and diagnostic limitation on operability by /sup 67/Ga-scintigraphy to primary lung cancer, minute hepatoma and abdominal abscess. Primary lung cancer: In detecting metastatic hilar lymph nodes, the sensitivity is 54%, and the specificity is 78%. In detecting metastatic mediastinal lymph nodes, the sensitivity is 32% and the specificity is 89%. Minute hepatoma : The detectability depended on the size of the lesion. It is hard to detect lesions with under 2 cm by /sup 67/Ga-scintigraphy. Abdominal abscess : The sensitivity is 88%, and the specificity is 92%.

  8. Lung perfusion scintigraphy in the diagnosis of peripheral pulmonary stenosis in patients after repair of Fallot tetralogy

    International Nuclear Information System (INIS)

    Sabiniewicz, R.; Chojnicki, M.; Alszewicz-Baranowska, J.; Erecinski, J.; Romanowicz, G.; Lass, P.; Bandurski, T.

    2002-01-01

    The frequency of peripheral pulmonary artery stenosis in patients after surgical repair of tetralogy of Fallot (TOF) ranges from 20 to 40%. This can be either primary or secondary to the surgical intervention. The influence of resulting lung perfusion alterations on the life quality of patients is difficult to predict. The aim of this study was to compare the utility of the diagnostic procedures in this group of patients, with particular focus on lung perfusion scintigraphy. This study comprised 104 patients who underwent repair of TOF at ages from 5 months to 25 years. The patients have been followed up for from 4.2 to 25 years. On the basis of chest X-ray peripheral pulmonary artery stenosis was suspected in 11 patients, in 12 on the basis of echocardiography examination. Lung perfusion scintigraphy has been performed on 87 patients. The disturbances in lung perfusion (mostly in the left lung) were show by means of lung perfusion scintigraphy in 43 (49%) of patients. In 27 of them heart catheterisation has been performed. Angiography revealed stenosis of the lung artery branch in 15/43 (34.9%) patients with abnormal perfusion lung scan and in 4/44 (9%) in patients with normal perfusion lung scan. Intervention procedures were carried out on 10 patients. Lung perfusion scintigraphy may prove a valuable, non-invasive screening tool in the assessment of patients after TOF repair, although both false-negative and false positive results may happen. Therefore, it should play an auxiliary role together with other diagnostic modalities. (author)

  9. Current role of lung scintigraphy in pulmonary embolism

    International Nuclear Information System (INIS)

    Giordano, A.; Angiolillo, D. J.

    2001-01-01

    The pivotal role of lung scintigraphy in the diagnosis of pulmonary embolism (PE) has been questioned in recent years due to the introduction of spiral computed tomography. However, the scintigraphic results used for comparisons are often those of the authoritative PIOPED (Prospective Investigation of Pulmonary Embolism Diagnosis) study, carried out in the 1980s. Pulmonary scintigraphy has progressed from those years both in the methodological and interpretative fields, although perhaps too slowly. Results better than those of PIOPED's have been presented by study groups who used: 1) perfusion-only approach; 2) SPET imaging; 3) new interpretative criteria; 4) different prediction rules to integrate clinical and scintigraphic probabilities of PE. These advances are still insufficiently recognised by the nuclear medicine community, possibly due to a sort of PIOPED-based cultural globalisation. This paper reviews the actual advantages and limitations of nuclear medicine techniques, the diagnostic role of scintigraphy within the diagnostic algorithms proposed by international working groups and scientific societies and the results obtained from SPET imaging in the diagnosis of PE

  10. Clinical evaluation of lung scintigraphy with sup 99m Tc-technegas

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Tomio; Watanabe, Naoyuki; Oriuchi, Noboru; Tateno, Madoka; Tomiyoshi, Katsumi; Mitomo, Osamu; Hayakawa, Kazushige; Niibe, Hideo [Gunma Univ., Maebashi (Japan). School of Medicine; Sasaki, Yasuhito

    1990-12-01

    The aim of this study is to evaluate the safety and clinical usefulness of the lung scintigraphy using {sup 99m}Tc-technegas produced by the evaporation of pertechnetate elution at 2500deg C. Lung images were recorded by the gammacamera-computer system after a few deep inspiration of {sup 99m}Tc-technegas. One healthy volunteer and 32 patients including 10 with lung cancer, 8 with chronic obstructive lung disease, 5 with pulmonary embolism, 2 with interstitial pneumonia, 2 with bronchiectasis and 12 with the other various diseases were studied. Delayed images were taken at more than 1 hour later in one healthy and 13 patients to investigate the interval changes of the intrapulmonary distribution of {sup 99m}Tc-technegas. Obvious difference of radioactive distribution between early and delayed images were observed in only 2/14 cases. Penetration index (P.I.) averaged 0.81{plus minus}0.11 for early images and 0.85{plus minus}0.12 for delayed images. There was no significant difference between P.I. for early and delayed images. More than 97 MBq of {sup 99m}Tc-macroaggregated albumin ({sup 99m}Tc-MAA) were required to obtain the adequate perfusion images after the acquisition of lung images with about 37 MBq of {sup 99m}Tc-technegas. Bronchial deposits of {sup 99m}Tc-technegas were shown in 12/33 cases and pathological defects in 26/32 patients (81.3%). Twenty three of 33 cases also had a perfusion scintigraphy with {sup 99m}Tc-MAA. Ventilation perfusion mismatches were presented in 5/5 patients with pulmonary embolism and 1/10 patients with lung cancer. The safety was confirmed in all cases and clinical usefulness in 30/32 patients (94%). In conclusion, the safety and clinical usefulness of the lung scintigraphy with {sup 99m}Tc-technegas were proven in this study. (author).

  11. Lung scintigraphy in the diagnosis of pulmonary embolism: current methods and interpretation criteria in clinical practice

    International Nuclear Information System (INIS)

    Skarlovnik, Ajda; Hrastnik, Damjana; Fettich, Jure; Grmek, Marko

    2014-01-01

    In current clinical practice lung scintigraphy is mainly used to exclude pulmonary embolism (PE). Modified diagnostic criteria for planar lung scintigraphy are considered, as newer scitigraphic methods, especially single photon emission computed tomography (SPECT) are becoming more popular. Data of 98 outpatients who underwent planar ventilation/perfusion (V/Q) scintigraphy and 49 outpatients who underwent V/Q SPECT from the emergency department (ED) were retrospectively collected. Planar V/Q images were interpreted according to 0.5 segment mismatch criteria and revised PIOPED II criteria and perfusion scans according to PISA-PED criteria. V/Q SPECT images were interpreted according to the criteria suggested in EANM guidelines. Final diagnosis of PE was based on the clinical decision of an attending physician and evaluation of a 12 months follow-up period. Using 0.5 segment mismatch criteria and revised PIOPED II, planar V/Q scans were diagnostic in 93% and 84% of cases, respectively. Among the diagnostic planar scans readings specificity for 0.5 segment mismatch criteria was 98%, and 99% for revised PIOPED II criteria. V/Q SPECT showed a sensitivity of 100% and a specificity of 98%, without any non-diagnostic cases. In patients with low pretest probability for PE, planar V/Q scans assessed by 0.5 segment mismatch criteria were diagnostic in 92%, and in 85% using revised PIOPED II criteria, while perfusion scintigraphy without ventilation scans was diagnostic in 80%. Lung scintigraphy yielded diagnostically definitive results and is reliable in ruling out PE in patients from ED. V/Q SPECT has excellent specificity and sensitivity without any non-diagnostic results. Percentage of non-diagnostic results in planar lung scintigraphy is considerably smaller when 0.5 segment mismatch criteria instead of revised PIOPED II criteria are used. Diagnostic value of perfusion scintigraphy according to PISA-PED criteria is inferior to combined V/Q scintigraphy; the difference is

  12. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    International Nuclear Information System (INIS)

    Thieme, Sven F.; Becker, Christoph R.; Hacker, Marcus; Nikolaou, Konstantin; Reiser, Maximilian F.; Johnson, Thorsten R.C.

    2008-01-01

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam

  13. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F.; Becker, Christoph R. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Hacker, Marcus [Department of Nuclear Medicine, Ludwig-Maximilians-University of Munich (Germany); Nikolaou, Konstantin; Reiser, Maximilian F. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Johnson, Thorsten R.C. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany)], E-mail: thorsten.johnson@med.uni-muenchen.de

    2008-12-15

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam.

  14. Aerosol lung inhalation scintigraphy in children with bronchial asthma

    International Nuclear Information System (INIS)

    Torii, Yoshikuni; Nakayama, Chikashi; Nakata, Hajime; Takahashi, Satomi; Tanaka, Masaaki; Koori, Tateo

    1988-01-01

    Aerosol lung inhalation scintigraphies performed on 37 children with bronchial asthma during asymptomatic periods were evaluated. The findings of their aerosol lung inhalation scintigrams were classified into 4 patterns, as type I: homogeneous distribution without hot spot formation, type II: peripheral homogeneity with central hot spot formation, type IIID (-): inhomogeneous distribution with hot spot formation, but without defect, and type IIID (+): with defect. These aerosol patterns were compared with those of previously reported adult cases and with the severity of bronchial asthma. Normal pattern of type I was found in 5 cases (12%) of our infantile asthmatics in contrast to previously reported adult cases, in which none of normal pattern was found. There were differences between type II and type III in both distribution and disappearance time of hot spot, which indicated that the two types differed from each other in radioaerosol deposition mechanism. There was no significant correlation between type I and type II in the severity of asthma and the frequency of asthmatic attack. Type II may be clinically considered to be the same type as type I. There is the statistically significant difference between type I, II and type III in the frequency of asthmatic attack, but not in the severity of asthma, although most of serious cases showed type III. Aerosol lung inhalation scintigraphy is a useful examination for children with bronchial asthma in which lung function tests may be difficult to perform. (author)

  15. Diagnostic performance of [18F] FDG PET-CT compared to bone scintigraphy for the detection of bone metastases in lung cancer patients

    International Nuclear Information System (INIS)

    RODRIGUES, Margarida; STARK, Hannes; RENDL, Gundula; RETTENBACHER, Lukas; PIRICH, Christian; DATZ, Lidwina; STUDNICKA, Michael

    2016-01-01

    Accurate staging of lung cancer is essential for effective patient management and selection of appropriate therapeutic strategy. The aim of this paper was to compare the value of bone scintigraphy and FDG PET-CT for detecting bone metastases in lung cancer patients and the impact of these modalities in disease staging. One hundred sixty-four lung cancer patients who had undergone both FDG PET-CT and bone scintigraphy within 14 days were included into this study. The analysis of FDG PET-CT and bone scintigraphy was carried out patient- and lesion-based. One hundred twenty-one patients were negative and 43 patients positive for bone metastases. FDG PET-CT found bone metastases in 42/43 patients and bone scintigraphy in 38/43 patients. Sensitivity, specificity and accuracy of FDG PET-CT and bone scintigraphy for detecting bone metastases were 97.7%, 100% and 99.4%, and 87.8%, 97.5% and 94.2%, respectively. FDG PET-CT identified 430 bone metastases and bone scintigraphy 246 bone metastases. Skull was the only region where bone scintigraphy identified more lesions than FDG PET-CT. Based on both scintigraphic modalities disagreement concerning disease stage was found in 3 patients. In conclusion, FDG PET-CT yielded a higher sensitivity, specificity and accuracy than bone scintigraphy for identifying bone metastases in lung cancer patients. FDG PET-CT thus can be recommended for initial staging of lung cancer patients without applying bone scintigraphy for the detection of bone metastases.

  16. Critical evaluation of lung scintigraphy in cystic fibrosis: study of 113 patients

    International Nuclear Information System (INIS)

    Piepsz, A.; Wetzburger, C.; Spehl, M.; Machin, D.; Dab, I.; Ham, H.R.; Vandevivere, J.; Baran, D.

    1980-01-01

    A long-term study has been performed on 285 lung perfusion scintigrams obtained from 113 patients with cystic fibrosis. Transverse and longitudinal comparisons with clinical and radiological scores, as well as retrospective analysis of the deceased patients, were the methods used in order to evaluate the importance of the scintigraphic images. It appears that lung scintigraphy is the best index of the regional lung impairment, and contributes, as does a chest radiograph, to the early detection of lung lesions, the two methods being complementary

  17. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Park, Sang Hyub [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2017-11-15

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy. (orig.)

  18. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Park, Sang Hyub

    2017-01-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy. (orig.)

  19. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy.

    Science.gov (United States)

    Goo, Hyun Woo; Park, Sang Hyub

    2017-11-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy.

  20. Scintigraphy at 3 months after single lung transplantation and observations of primary graft dysfunction and lung function

    DEFF Research Database (Denmark)

    Belmaati, Esther Okeke; Iversen, Martin; Kofoed, Klaus F

    2012-01-01

    procedure 3 months after single lung transplantation (SLTX). A total of 41 patients were included in the study: 20 women and 21 men with the age span of patients at transplantation being 38-66 years (mean ± SD: 54.2 ± 6.0). Patient records also included lung function tests and chest X-ray images. We found......Scintigraphy has been used as a tool to detect dysfunction of the lung before and after transplantation. The aims of this study were to evaluate the development of the ventilation-perfusion relationships in single lung transplant recipients in the first year, at 3 months after transplantation...

  1. Diagnostic value of static and dynamic scintigraphy in diagnosis of acute respiratory distress syndrome in the course of sepsis. Part 2. Lung aerosol scintigraphy

    International Nuclear Information System (INIS)

    Jurgilewicz, D.; Rogowski, F.; Malinowska, L.

    1997-01-01

    Rapid increase in permeability of functionally and/or structurally damaged alveolar-capillary barrier is the pivotal factor in non-cardiogenic pulmonary edema development. Rate of exudative changes progress in the lungs decides about prognosis in patients with this serious, over 50% death rate, syndrome. The aim of the study was to estimate the usefulness of dynamic lung scintigraphy in diagnosis of gas exchange abnormalities in sepsis and ARDS. Aerosol scintigraphy with pulmonary clearance of DTPA in 6 septic and in 6 ARDS patients were performed. Studies were done using planar gamma camera, type MB9200, in A-P projection. They were analyzed with the modified NMS Warsaw Polytechnic computer program. Aerosol scintiscans demonstrated very irregular borderlines of both lungs, features of marked impairment in ventilation (with foci of increased radioactivity in the view of main bronchi) and about 2.5-fold faster pulmonary clearance of DTPA in ARDS patients comparing to sepsis and control groups. The results showed that dynamic scintigraphy can be safely performed in patients in critical condition. Changes in scintiscans and rapid pulmonary clearance of DTPA might be an early indicator of ARDS development in septic patients. (author)

  2. Studies on the correlation between pre-and post-operative perfusion scintigraphy and differential spirometry in operated lungs

    International Nuclear Information System (INIS)

    Kaseda, Shizuka; Ikeda, Takaaki; Sakai, Tadaaki; Tomaru, Hiroko; Ishihara, Tsuneo; Kikuchi, Keiichi.

    1982-01-01

    For the purpose of clarifying the relationship between the percentage of perfusion and that of vital capacity or oxygen uptake on the affected lung, perfusion scintigraphy using sup(99m)Tc-MAA and differential spirometry were performed in twenty patients including sixteen patients with lung cancer. Both examinations were performed before and after the operation. The results are as follows: (1) There is a significant correlation between the percentage of perfusion and that of vital capacity or oxygen uptake of the affected lung before and after the operation. (2) The estimation of the percentage of vital capacity or oxygen uptake of the affected lung is possible by combining the spirometry and sup(99m)Tc-MAA pulmonary scintigraphy. (author)

  3. Radioaerosol inhalation lung scintigraphy in bronchial asthma

    International Nuclear Information System (INIS)

    Chiba, Takashi

    1993-01-01

    A study on obstructive changes in airways and mucociliary clearance in children and youth with bronchial asthma was performed. Radioaerosol inhalation lung scintigraphies using 99T c-human serum albumin (HSA) were applied to 50 children and youth with bronchial asthma. The deposition patterns of the radioaerosol and aerosol clearance curves were evaluated. Abnormal deposition patterns, which consisted of non-homogeneous distribution and/or hot spot formation, were likely to be seen in patients with asthmatic attacks at the time of measurements. However, a few asymptomatic patients also revealed abnormal deposition patterns. The deposition patterns were related to FEV 1.0 %, MMF, V 50 and V 25 , but especially to FEV 1.0 %. As an index of mucociliary clearance, β, the rate constant of the 99m Tc-HSA aerosol clearance curve, was introduced. β was significantly lower in patients with abnormal aerosol deposition patterns than in normal persons. β was also significantly lower in patients undergoing asthmatic attack at the time of the measurements than in asymptomatic patients. β correlated negatively with FEV 1.0 %, MMF, V 50 and V 25 , but especially with FEV 1.0 %. Although patients with long term affection or moderate-to-severe asthma tended to reveal abnormal deposition patterns and had low β values, these differences were not statistically significant. Radioaerosol inhalation lung scintigraphy with 99m Tc-HSA is useful for evaluating not only obstructive changes in the airways but also for evaluating mucociliary clearance in children with bronchial asthma. (author)

  4. Information for the diagnosis of broncho-pulmonary diseases obtained by the combined use of perfusion lung scintigraphy and selective bronchial arteriography

    International Nuclear Information System (INIS)

    Wouamba Foning, Michel.

    1976-01-01

    Our study is limited to perfusion lung scintigraphy and deals with the following in turn: - radioisotopes and their conditioning, - detection and recording equipment, - results and limits of the method. The tracers used here were radioiodine-labelled human albumin macro-aggregates and more especially technetium-labelled microspheres. Scintigraphy, which visualizes or charts the local distribution of radioactive indicators, is carried out with two kinds of apparatus, scanners and scintillation cameras. The information acquired may be accurately analysed at the same time owing to modern data processing systems. The interpretation of radiotracer lung transit curves made by several authors is not very useful for our work, consequently we have kept to the analysis of images obtained by the Anger camera or similar instruments. The Anger scintillation camera seems to be well suited to isotopic lung exploration providing morphological and functional data simultaneously. Perfusion lung scintigraphy, which reflects the quality of lung circulation at the capillary level, appears to be a valuable asset in the diagnostic approach to certain chest X-ray images. The technique is fast, painless, neat, harmless and almost never contra-indicated. However like other techniques it cannot solve every problem on its own. Under these conditions, we must admit, on weighing up the results of this study, that perfusion lung scintigraphy had to be followed in most cases by selective bronchial arteriography [fr

  5. A new application of Bull's eye analysis to lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yasui, Kotaro; Kohno, Yoshihiro; Akaki, Shiro; Hasegawa, Mari; Nakagawa, Tomio; Simizu, Mitsuharu; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao.

    1990-01-01

    Technetium-99m macroaggregated albumin lung perfusion scintigraphy was performed and evaluated semiquantitatively by Bull's eye analysis in 24, including 7 with central pulmonary carcinoma, 3 with hypersensitivity pneumonitis (HP), 3 with diffuse panbronchiolitis (DPB) and 11 normal subjects. First, whole lung field was divided into three regions by three concentric circles. And then radial axes were projected from the center to define 36 sectors, 10 degree each. The counts of each sector was calculated and Bull's eye image and circumferential profile curve were displayed. The patient's map was compared with the lower limit of normal (mean-2 SD), and the extent score (ES) and the severity score (SS) were calculated. The ES was 0.25±0.12 in pulmonary carcinoma (n=7), 0.08±0.07 in HP (n=3), 0.06±0.04 in DPB (n=3). The SS was 26.39±15.17 in pulmonary carcinoma, 4.75±5.57 in HP, 4.29±3.67 in DPB. In one case of central pulmonary carcinoma, segmental perfusion defect was evaluated semiquantitatively by Bull's eye image and circumferential profile curve. And in one case of HP, the change of regional pulmonary blood flow could be followed easily using extent and severity map. This new application of Bull's eye analysis to lung perfusion scintigraphy might be useful to evaluate regional pulmonary blood flow. (author)

  6. Evaluation of Tl-201 lung uptake and impairment of pulmonary perfusion on scintigraphies in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Koizumi, Tomonori; Kubo, Keishi

    2000-01-01

    Tl-201 lung uptake in 74 patients (85 lesions) and pulmonary perfusion in 105 patients were studied to evaluate clinical usefulness of Tl-201 lung uptake and perfusion lung scintigraphy in pulmonary tuberculosis, using a scintillation camera with a mini-computer system. As indices of Tl-201 lung uptake, lung (lesion) to upper mediastinum uptake ratio (L/M) and visual grading were used. L/M in pulmonary tuberculosis was 1.96±0.66, which was significantly larger than 1.04±0.24 in healthy controls and lower than that in heart diseases with left heart failure and idiopathic interstitial pneumonia, and showed no significant differences with that in acute pneumonia, pyothorax, primary lung cancer and malignant mediastinal tumor. L/M in pulmonary tuberculosis did not correlate with CRP, erythrocyte sedimentation rate, Gaffky number of sputum and body temperature. It correlated with the type of pulmonary tuberculosis according to the Gakken Classification reflecting the disease activity. It was larger in the exudative type, caseo-infiltrative one, disseminated one, one with cavity in infiltrative lesion than the fibro-caseous one. On perfusion lung scintigram, impairment of pulmonary perfusion larger than area of the entire unilateral lung was observed in 68 cases (64.8%). Area of hypoperfused lung field, which correlated with % vital capacity (r=0.60, p=0.0002) and PaO 2 (r=0.39,p=0.0024), was significantly larger in patients with silicosis and those with bilateral pleural involvements such as pleural callosity than in those with type III according to the Gakkai Classification. Most of the patients showed decreased pulmonary perfusion and Tl-201 accumulation of which grade reflects the disease activity in active tuberculous lesion. Patients with miliary tuberculosis and those with silicotuberculosis showed diffuse Tl-201 accumulation in the both lungs. Tl-201 lung scintigraphy seems to be useful for visualizing active tuberculous lesions, particularly the ones that

  7. Role of Scintigraphy with Technetium-99m Depreotide in the Diagnosis and Management of Patients with Suspected Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Axelsson, R.; Herlin, G.; Baaaath, M.; Aspelin, P.; Koelbeck, K.G. (Div. of Radiology, Dept. of Clinical Science, Intervention and Technology (CLINTEC), and Div. of Pulmonary Medicine and Allergology, Dept. of Medicine, Karolinska Inst., Stockholm (Sweden))

    2008-04-15

    Background: In Sweden, there are over 3000 new lung cancer cases every year. There are still numerous patients with undetermined lesions after routine diagnostic evaluation by clinical examination, chest radiography, computed tomography (CT) of the thorax, and bronchoscopy. An appropriate method for further diagnostic workup is therefore needed. Purpose: To evaluate the diagnostic value of the somatostatin analogue depreotide in patients with suspected lung cancer, and to determine in which clinical settings it would be beneficial to use 99mTc-depreotide scintigraphy. Material and Methods: We included 99 consecutive patients referred to our hospital with suspected lung cancer. A clinical examination, bronchoscopy, chest radiography, CT of the thorax and upper abdomen, and scintigraphy were done. Scintigraphy was performed after injection of 740 MBq 99mTc depreotide with tomographical imaging of the thorax and whole-body scanning. The diagnostic outcome of the scintigrams was compared to CT, using morphology or clinical outcome as the endpoint. Results: 99mTc-depreotide uptake was found in 62 out of 66 malignancies, including 57 of 58 primary lung cancer cases. Two cases of lung metastasis (one from a colon cancer and one from an adenoid cystic carcinoma originating in the palate) and one rib chondrosarcoma did not show depreotide uptake. There were 33 patients with benign lesions, of whom 16 displayed false-positive 99mTc-depreotide uptake, whereof 11 were pneumonias. Tc-99m-depreotide uptake was absent in 17 patients with benign lesions, including all 10 hamartomas. The sensitivity in detecting malignancy was 94%, and in detecting lung cancer 98%. The specificity was calculated based on two sets of data. When all cases were used, the specificity was 52%. If the 12 pneumonias are excluded, the specificity was 77%. Conclusion: 99mTc-depreotide scintigraphy has a high sensitivity in detecting lung cancer. The method is useful in decision-making with respect to

  8. Role of Scintigraphy with Technetium-99m Depreotide in the Diagnosis and Management of Patients with Suspected Lung Cancer

    International Nuclear Information System (INIS)

    Axelsson, R.; Herlin, G.; Baaaath, M.; Aspelin, P.; Koelbeck, K.G.

    2008-01-01

    Background: In Sweden, there are over 3000 new lung cancer cases every year. There are still numerous patients with undetermined lesions after routine diagnostic evaluation by clinical examination, chest radiography, computed tomography (CT) of the thorax, and bronchoscopy. An appropriate method for further diagnostic workup is therefore needed. Purpose: To evaluate the diagnostic value of the somatostatin analogue depreotide in patients with suspected lung cancer, and to determine in which clinical settings it would be beneficial to use 99m Tc-depreotide scintigraphy. Material and Methods: We included 99 consecutive patients referred to our hospital with suspected lung cancer. A clinical examination, bronchoscopy, chest radiography, CT of the thorax and upper abdomen, and scintigraphy were done. Scintigraphy was performed after injection of 740 MBq 99m Tc depreotide with tomographical imaging of the thorax and whole-body scanning. The diagnostic outcome of the scintigrams was compared to CT, using morphology or clinical outcome as the endpoint. Results: 99m Tc-depreotide uptake was found in 62 out of 66 malignancies, including 57 of 58 primary lung cancer cases. Two cases of lung metastasis (one from a colon cancer and one from an adenoid cystic carcinoma originating in the palate) and one rib chondrosarcoma did not show depreotide uptake. There were 33 patients with benign lesions, of whom 16 displayed false-positive 99m Tc-depreotide uptake, whereof 11 were pneumonias. Tc-99m-depreotide uptake was absent in 17 patients with benign lesions, including all 10 hamartomas. The sensitivity in detecting malignancy was 94%, and in detecting lung cancer 98%. The specificity was calculated based on two sets of data. When all cases were used, the specificity was 52%. If the 12 pneumonias are excluded, the specificity was 77%. Conclusion: 99m Tc-depreotide scintigraphy has a high sensitivity in detecting lung cancer. The method is useful in decision-making with respect to

  9. The utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for assessment of lung lesions in patients with neuroendocrine tumors.

    Science.gov (United States)

    Pavlovic, S; Artiko, V; Sobic-Saranovic, D; Damjanovic, S; Popovic, B; Jakovic, R; Petrasinovic, Z; Jaksic, E; Todorovic-Tirnanic, M; Saranovic, D; Micev, M; Novosel, S; Nikolic, N; Obradovic, V

    2010-01-01

    Our aim was to assess clinical utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for evaluation of lung lesions in patients with neuroendocrine tumors (NETs). Single photon emission computed tomography (SPECT) of the thorax and whole body scintigraphy were performed in 34 patients using 99mTc-EDDA/HYNIC-TOC. Visual assessment was complemented by semiquantitative evaluation based on tumor to non-tumor (T/NT) ratio. Clinical, laboratory, and histological findings served as the standard for comparison. Enhanced tracer uptake was observed on both SPECT and whole body scintigraphy in 29 of 34 patients (88% sensitivity). T/NT ratios were significantly higher on SPECT than whole body images (2.96+/-1.07 vs.1.70+/-0.43, p 99mTc-EDDA/Hynic-TOC, lung involvement of NETs, T/NT ratio.

  10. Lung perfusion and ventilation scintigraphy in pre- and postoperative diagnostics

    International Nuclear Information System (INIS)

    Sandrock, D.; Munz, D.L.

    1998-01-01

    Lung perfusion (Tc-99m labeled albumin particles) and ventilation (Xe-133 gas) are used prior to thoracic surgery in order to evaluate changes in perfusion and ventilation due to the underlying diseases. Furthermore, perfusion scintigraphy allows combined with spirometry the prediction of the postinterventional vital capacity and the forced expiratory volume in 1 s. The correlation coefficient for this procedure compared with values measured postoperatively are in the range of 0.8. The method allows the assessment of operability in terms of postinterventional function. (orig.) [de

  11. {sup 99m}Tc-MIBI scintigraphy for early detection of locally recurrent non-small cell lung cancer treated with definitive radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Masaya; Nozaki, Miwako; Kawashima, Miho; Iimuro, Mamoru; Kitazumi, Yoshinori; Okayama, Aya; Natsui, Satoshi [Department of Radiology, Koshigaya Hospital, Dokkyo University School of Medicine, 2-1-50 Minami-Koshigaya, 343-8555, Koshigaya (Japan); Hamashima, Yoshio; Nagao, Koushuu [Department of Respiratory Internal Medicine, Koshigaya Hospital, Dokkyo University School of Medicine, Koshigaya (Japan)

    2003-07-01

    After radiation therapy of lung cancer, a dense fibrotic shadow develops in the irradiated lung. Owing to this fibrosis, early detection of local recurrence after treatment is sometimes difficult even when using computed tomography (CT) and magnetic resonance imaging. We investigated the diagnostic accuracy of technetium-99m hexakis 2-methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) scintigraphy for the detection of recurrent lung cancer following definitive radiation therapy. Eighteen patients with primary non-small cell lung cancer treated with radiation therapy 1 year previously were studied with {sup 99m}Tc-MIBI scintigraphy. They showed no evidence of local recurrence on serial chest radiographs. All single-photon emission tomography (SPET) images acquired 2 h after intravenous administration of the radiopharmaceutical were visually interpreted with knowledge of the pretreatment chest radiograph, CT and the details of radiation therapy (radiation portals and administered doses). A region of interest (ROI) analysis was also performed. In addition to the ROI ratio of tumour uptake to accumulation in contralateral normal lung (tumour/lung ratio), another semiquantitative analysis, the ratio of tumour uptake to accumulation in radiation fibrosis (tumour/fibrosis ratio), was performed to differentiate between accumulation in radiation fibrosis and the tumour uptake. The scintigraphic diagnoses were correlated with clinical outcome. The sensitivity, specificity and negative predictive value of {sup 99m}Tc-MIBI scintigraphy for the detection of recurrent lung cancer were all 88.9% (8/9). The tumour/lung ratios (mean{+-}SEM) of the nine patients with local recurrence and the other eight without local failure were 2.00{+-}0.11 and 1.40{+-}0.09, respectively (P<0.01). The tumour/fibrosis ratios of the patients with and those without recurrence were 1.47{+-}0.08 and 0.93{+-}0.05, respectively (P<0.01). These results suggest that {sup 99m}Tc-MIBI scintigraphy might be of

  12. Uptake of radiocolloid, (2). Lung uptake of sup(99m)Tc-Sn-colloid during liver scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Y [Showa Univ., Tokyo (Japan). School of Medicine

    1980-10-01

    Forty-one of RI lung accumulation were selected from 1536 cases among liver scintigraphy of sup(99m)Tc-Sn-colloid. The results of analysis of these cases are as follows: 1) The cases of lung accumulation caused by failure of preparing sup(99m)Tc-Sn-colloid were excluded. The lung accumulation in liver scintigraphy was able to be found only in sup(99m)Tc-Sn-colloid with large sized particle. 2) From several facts, it is not considered that sup(99m)Tc-colloid was taken into the lung in form of macroaggregation after injection. 3) The lung accumulation of sup(99m)Tc-colloid was not always detected in the cases with any liver disorder. 4) The great majority of cases with the lung accumulation were malignant tumor, the next was liver cirrhosis. When the patients were in the most severe condition, sup(99m)Tc-colloid was apt to be revealed in the lung. In the cases of children, the marked accumulation of the lung was always observed. 5) The lung accumulation of sup(99m)Tc-Sn-colloid was also observed in many patients with splenomegaly without liver disease. It is not a phenomena from the result of decrease in hepatic blood flow or of portal hypertension, but it may be related with certain immunological change. 6) Most patients with the lung accumulation were in extremely severe condition and their survival was not so good. Therefore, this phenomena could refer to a indicator of poor prognosis. 7) The lung accumulation of RI colloid may be revealed when patients fall into extremely severe stage and pulmonary macrophages are stimulated. Its phenomena would be essentially caused by a mechanism that RI-colloid are phagocyted by pulmonary macrophages.

  13. Estimation of pulmonary hypertension of congenital heart diseases in children by lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Zheng Jinghao; Zhang Shantong; Zeng Jiye; Jia Hongli; Ji Zhiying; Chen Siyi

    1993-01-01

    The authors report that changes in the distribution of pulmonary perfusion caused by gravitation effect, namely, changes in the total count ratios of the right against the left lung between right and left lateral decubitus positions (rt/lt) could estimate pulmonary hypertension using lung perfusion scintigraphy with 99m Tc-labelled macroaggregated albumin. The results showed: rt/lt was inversely related to mean pulmonary arterial pressure. It is concluded that the method is simple, safe, reproducible, unaffected by cardiac structural abnormality and valuable as a noninvasive approach for the estimation of pulmonary hypertension

  14. 111Indium-labeled neutrophil migration into the lungs of bleomycin-treated rabbits assessed noninvasively by external scintigraphy

    International Nuclear Information System (INIS)

    Haslett, C.; Shen, A.S.; Feldsien, D.C.; Allen, D.; Henson, P.M.; Cherniack, R.M.

    1989-01-01

    Factors controlling neutrophil migration into the lung are poorly understood, but their identification is important for our understanding of the pathogenesis of inflammatory lung diseases. Pulmonary inflammation is difficult to quantify, and neutrophils in tissues and BAL may not accurately represent cell migration. In this study, intravenously delivered pulses of rabbit neutrophils labeled with Indium-111 (111In-neutrophils) were used to monitor neutrophil migration into the lungs. Radioactivity quantified in the lung region of interest (ROI) of external gamma camera scintigrams recorded 24 h after intravenous 111In-neutrophil injection accurately reflected the actual neutrophil-associated lung tissue radioactivity. ROI radioactivity at 24 h also correlated closely with the percent of 111In-neutrophils that had migrated into lavageable air spaces, and this parameter therefore provided an index of total lung 111In-neutrophil migration. Using 24-h ROI radioactivity and percent of injected 111In-neutrophils recovered in BAL at 24 h as indices of neutrophil migration into the lung, it was found that intratracheal saline caused only a transient neutrophil migration, whereas 10 U/kg intratracheal bleomycin induced migration that persisted for as long as 3 wk. 111In-neutrophil migration into the lung, assessed by external scintigraphy, correlated with total neutrophils quantified in histologic sections (r = 0.71, p = 0.006). The data suggest that this approach will be valuable in investigating mechanisms controlling neutrophil migration in lung inflammation, and that 111In-neutrophil scintigraphy may provide a noninvasive index of total lung neutrophil load that might be useful in staging inflammation in patchy diseases such as idiopathic pulmonary fibrosis

  15. Studies on pulmonary ventilation-perfusion scintigraphy with Xe-133 in primary lung cancer, 1

    International Nuclear Information System (INIS)

    Oshibuchi, Masao

    1984-01-01

    Regional lung ventilation-perfusion scintigraphy by xenon gas was performed on 14 normal cases (normal group) and 86 cases of primary lung cancer (lung cancer group). The patients were measured in a sitting position using a scintillation camera. In normal group, the value of V, Q was higher in the lower lung field than in the upper lung field, the value of MTT was rather delayed in the upper lung field than in the lower lung field, proving to that lung clearance was better in the lower lung field than in the upper lung field. In lung cancer group, VQ match (pattern I, II) was 61 cases (71%) and VQ mismatch (pattern III, IV) was 25 cases (29%). The pattern II (VQ matched defect) accounted for 63% in lung cancer group. In this pattern, the region of disorder of V and Q was corresponded respectively, but disorder grade was not always accorded. The pattern III (normal V and disordered Q) was mainly seen in AH group (hilar type) and D group (lymph node swelling type). The V/Q in lung cancer group was widely distributed to the range of 0 to 5.8. The value of MTT was rather delayed in all cases of lung cancer group than in the normal group, because delayed MTT in focal lesion was markedly affected to whole lung. (author)

  16. Diffuse Thyroid Metastasis From Lung Cancer Mimicking Thyroiditis on 99mTc-Pertechnetate Scintigraphy.

    Science.gov (United States)

    Gao, Rui; Gao, Shan; Feng, Jinteng; Wang, Yuanbo; Zhang, Guangjian

    2017-09-01

    Possible thyroiditis was suspected in a 56-year-old man who initially presented sore throat because laboratory examinations revealed decreased serum thyroid hormone and the Tc-pertechnetate scintigraphy showed no tracer uptake by the thyroid gland. However, subsequent examination demonstrated that the absence of pertechnetate activity in the thyroid was due to complete replacement of thyroid gland by the metastasis from lung adenocarcinoma, which was unknown at the initial presentation.

  17. Evaluation of lung epithelial permeability in the volatile substance abuse using Tc-99m DTPA aerosol scintigraphy

    International Nuclear Information System (INIS)

    Cayir, D.; Demirel, K.; Korkmaz, M.; Koca, G.

    2011-01-01

    Chronic inhalant use is associated with significant toxic effects, including neurological, renal, hepatic, and pulmonary damage. However, there is a paucity of reports regarding respiratory complications in inhalant abusers. The aim of this study was to evaluate pulmonary epithelial permeability in the volatile substance abuse (VSA) using technetium-99m-labeled diethylenetriamine pentaacetic acid (Tc-99m DTPA) aerosol scintigraphy. This study included 18 patients with volatile substance abuse and 18 volunteer controls. All of patients and controls were smokers. Tc-99m DTPA aerosol scintigraphy was performed in all cases. Time-activity curves from each lung were generated and clearance half-time (T 1/2 ) of Tc-99m DTPA were calculated. T 1/2 of whole lung was calculated as a mean of the T 1/2 of left and right lung. The T 1/2 values of Tc-99m DTPA clearance in the substance abusers were significantly decreased as compared to the control group with respective mean values of 28.86±8.44, and 62.14±26.12 min (p=0.001). It was seen Tc-99m DTPA clearance from lung was faster as the duration of substance abuse was increased. Tc-99m DTPA pulmonary clearance is markedly accelerated in the volatile substance abuse. This suggests that inhalant abuse of substance may produce abnormalities in pulmonary alveolo-capillary membrane function. (author)

  18. Evaluation of lung epithelial permeability in the volatile substance abuse using Tc-99m DTPA aerosol scintigraphy.

    Science.gov (United States)

    Cayir, Derya; Demirel, Koray; Korkmaz, Meliha; Koca, Gokhan

    2011-10-01

    Chronic inhalant use is associated with significant toxic effects, including neurological, renal, hepatic, and pulmonary damage. However, there is a paucity of reports regarding respiratory complications in inhalant abusers. The aim of this study was to evaluate pulmonary epithelial permeability in the volatile substance abuse (VSA) using Tc-99m DTPA aerosol scintigraphy. This study included 18 patients with volatile substance abuse and 18 volunteer controls. All of patients and controls were smokers. Tc-99m DTPA aerosol scintigraphy was performed in all cases. Time-activity curves from each lung were generated and clearance half-time (T(1/2)) of Tc-99m DTPA were calculated. T(1/2) of whole lung was calculated as a mean of the T(1/2) of left and right lung. The T(1/2) values of Tc-99m DTPA clearance in the substance abusers were significantly decreased as compared to the control group with respective mean values of 28.86 ± 8.44, and 62.14 ± 26.12 min (p = 0.001). It was seen Tc-99m DTPA clearance from lung was faster as the duration of substance abuse was increased. Tc-99m DTPA pulmonary clearance is markedly accelerated in the volatile substance abuse. This suggests that inhalant abuse of substance may produce abnormalities in pulmonary alveolo-capillary membrane function.

  19. Accuracy and feasibility of dynamic contrast-enhanced 3D MR imaging in the assessment of lung perfusion: comparison with Tc-99 MAA perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yilmaz, E.; Akkoclu, A.; Degirmenci, B.; Cooper, R.A.; Sengun, B.; Gulcu, A.; Osma, E.; Ucan, E.S.

    2005-01-01

    AIM: The aim of this study was to correlate findings of perfusion magnetic resonance imaging (MRI) and perfusion scintigraphy in cases where there was a suspicion of abnormal pulmonary vasculature, and to evaluate the usefulness of MRI in the detection of perfusion deficits of the lung. METHODS: In all, 17 patients with suspected abnormality of the pulmonary vasculature underwent dynamic contrast-enhanced MRI. T1-weighted 3D fast-field echo pulse sequences were obtained (TR/TE 3.3/1.58 ms; flip angle 30 deg ; slice thickness 12 to 15 mm). The dynamic study was acquired in the coronal plane following administration of 0.1 mmol/kg gadopentetate dimeglumine. A total of 8 to 10 sections repeated 20 to 25 times at intervals of 1 s were performed. Perfusion lung scintigraphy was carried out a maximum of 48 h before the MR examination in all cases. Two radiologists, who were blinded to the clinical data and results of other imaging methods, reviewed all coronal sections. MR perfusion images were independently assessed in terms of segmental or lobar perfusion defects in the 85 lobes of the 17 individuals, and the findings were compared with the results of scintigraphy. RESULTS: Of the 17 patients, 8 were found to have pulmonary emboli, 2 chronic obstructive pulmonary disease with emphysema, 2 bullous emphysema, 2 Takayasu arteritis and 1 had a hypoplastic pulmonary artery. Pulmonary perfusion was completely normal in 2 cases. In 35 lobes, perfusion defects were detected using both methods, in 4 with MR alone and in 9 only with scintigraphy. There was good agreement between MRI and scintigraphy findings (kappa=0.695). CONCLUSION: Pulmonary perfusion MRI is a new alternative to scintigraphy in the evaluation of pulmonary perfusion for various lung disorders. In addition, this technique allows measurement and quantification of pulmonary perfusion abnormalities

  20. Technetium-99m hexamethylpropylene amine oxime leucocyte scintigraphy for the diagnosis of bone and joint infections: a retrospective study in 116 patients

    International Nuclear Information System (INIS)

    Devillers, A.; Moisan, A.; Jean, S.; Arvieux, C.; Bourguet, P.

    1995-01-01

    The aim of this study was to evaluate the diagnostic value of technetium-99m hexamethylpropylene amine oxime leucocyte scintigraphy (HMPAO-LS) by means of a retrospective review of 116 patients divided into three groups of bone and joint infection. One hundred and thirty-one LS examinations were performed, and 143 sites analysed. The final diagnosis of infection was based on surgical, histological and bacteriological data and follow-up. Ninety-four suspected localizations were examined in group 1, which included 74 patients with an infection suspected to involve orthopaedic implants. In this group, there were 38 true-positives, 1 false-negative, 49 true-negatives and 6 false-positives. Surgical confirmation was obtained in 34 cases. In group 2 (24 patients with suspected osteomyelitis), there were 27 localizations of which 14 were true-positives and 13 were true-negatives (including seven surgical confirmations). In group 3 (18 patients suspected of septic arthritis) there were eight true-positives, two false-negatives, ten true-negatives and two false-positives. Overall sensitivity of 99m Tc-HMPAO-LS for the detection of bone and joint infection was 95%, with a specificity of 90% (group 1: sensitivity 97%, specificity 89%; group 2: 100% and 100%; group 3: 80% and 83%). It may be concluded that HMPAO-LS is an effective tool for the diagnosis of both bone infection involving implants and chronic osteomyelitis. (orig.)

  1. Prediction of postoperative lung function after pulmonary resection

    International Nuclear Information System (INIS)

    Yoshikawa, Koichi

    1988-01-01

    Lung scintigraphy and ordinary lung function test as well as split lung function test by using bronchospirometry was performed in 78 patients with primary lung cancer and clinical significance of ventilation and perfusion scintigraphy was evaluated. Results obtained from this study are as follows. 1) The ratio of right VC to total VC obtained by preoperative bronchospirometry was well correlated to the ratio of right lung count to the total lung count obtained by ventiration and/or perfusion scintigraphy (r = 0.84, r = 0.69). 2) Evaluation of the data obtained from the patients undergoing pneumonectomy indicated that the right and left VC obtained preoperatively by bronchospirometry have their clinical significance only in the form of left to right ratio not in the form their absolure value. 3) As to the reliability of predicting the residual vital capacity after pneumonectomy on the basis of left-to-right of lung scintigraphy, ventilation scintigraphy is more reliable than perfusion scintigraphy. 4) Irrespective of using ventilation scintigraphy or perfusion scintigraphy, Ali's formular showed high reliability in predicting the residual vital capacity as well as FEV 1.0 after lobectomy. 5) Reduction of the perfusion rate in the operated side of the lung is more marked than of the ventilation rate, resulting in a significant elevation of ventilation/perfusion ratio of the operated side of the lung. From the results descrived above, it can be said that lung ventilation and perfusion scintigraphy are very useful method to predict the residual lung function as well as the change of ventilation/perfusion ratio after pulmonary resection. (author)

  2. Efficacious Oxime for Organophosphorus Poisoning: A Minireview ...

    African Journals Online (AJOL)

    Oximes are well known as acetylcholinesterase reactivators and are used in organophosphorus poisoning to reactivate inhibited acetylcholinesterase. Therapeutically available oximes, namely, pralidoxime (2-PAM), obidoxime, trimedoxime and Hagedorn oxime (HI-6), have no broad-spectrum activity against structurally ...

  3. Ventilation scintigraphy of the lung with sup(99m)Tc-DTPA or with sup(99m)Tc-sulfur colloid

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, D; Matthys, H; Coates, G; Dolovich, M; Newhouse, M

    1983-04-01

    Ventilation scintigraphy of the lung, obtained with sufficiently small sup(99m)Tc-labelled aerosol particles, provides an image of ventilation distribution that is acceptable in clinical routine. Whether sup(99m)Tc-DTPA or sup(99m)Tc-sulfur colloid is more suitable as a carrier was studied in 6 smokers and 8 non-smokers with chronic obstructive pulmonary disease. sup(99m)Tc-sulfur colloid was not absorbed by the bronchial mucosa and therefore appears to be an almost ideal agent. In contrast, sup(99m)Tc-DTPA was absorbed by the bronchial mucosa in all smoking patients more rapidly and inhomogenously than in non-smokers. The quantitative and qualitative comparison of the two dorsal ventilation scans taken both immediately after inhalation and 20 min later, showed in all 6 smoking patients after 20 min significant differences which influenced the diagnostic result. sup(99m)Tc-DTPA is therefore not recommended for use in ventilation lung scintigraphy, especially in smoking patients.

  4. First results of functional RES scintigraphy using sup(99m)-Tc-labeled human serum albumin millimicrospheres in progressive scleroderma: Possibility of early diagnosis of lung involvement

    International Nuclear Information System (INIS)

    Munz, D.L.; Altmeyer, P.; Ehrenheim, C.; Tuengerthal, S.; Holzmann, H.; Hoer, G.; Frankfurt Univ.

    1984-01-01

    Functional RES scintigraphy with sup(99m)Tc-labeled human serum albumin millimicrospheres (sup(99m)Tc-HSA-MM) was conducted in 11 female patients suffering from progressive scleroderma. The RES scan revealed abnormalities in the bone marrow in eight patients as well as pathological changes of the liver in 2 cases. 7 patients showed diffusely enhanced concentrations of sup(99m)Tc-HSA-MM in the lung, whereas X-ray picture and pulmonary function test revealed pathological findings in only 4 patients, respectively. Humoral inflammatory and immunologic parameters, too, indicated abnormalities less frequently than the lung scan. Thus functional RES scintigraphy seems to be a very sensitive approach to the assessment and possibly to the early diagnosis of lung involvement in progressive scleroderma. (orig.) [de

  5. First results of functional RES scintigraphy using sup(99m)-Tc-labeled human serum albumin millimicrospheres in progressive scleroderma: Possibility of early diagnosis of lung involvement

    Energy Technology Data Exchange (ETDEWEB)

    Munz, D.L.; Altmeyer, P.; Ehrenheim, C.; Tuengerthal, S.; Holzmann, H.; Hoer, G.

    1984-01-01

    Functional RES scintigraphy with sup(99m)Tc-labeled human serum albumin millimicrospheres (sup(99m)Tc-HSA-MM) was conducted in 11 female patients suffering from progressive scleroderma. The RES scan revealed abnormalities in the bone marrow in eight patients as well as pathological changes of the liver in 2 cases. 7 patients showed diffusely enhanced concentrations of sup(99m)Tc-HSA-MM in the lung, whereas X-ray picture and pulmonary function test revealed pathological findings in only 4 patients, respectively. Humoral inflammatory and immunologic parameters, too, indicated abnormalities less frequently than the lung scan. Thus functional RES scintigraphy seems to be a very sensitive approach to the assessment and possibly to the early diagnosis of lung involvement in progressive scleroderma.

  6. Efficacious Oxime for Organophosphorus Poisoning: A Minireview

    African Journals Online (AJOL)

    Erah

    Abstract. Oximes are well known as acetylcholinesterase reactivators and are used in ... activity against structurally different kinds of organophosphorus ... serious threat with regard to occupational .... choose an oxime for unknown OPC exposure. Secondly, there is a lack of .... oximes, and hence cannot pass the blood.

  7. Native and tabun-inhibited cholinesterase interactions with oximes

    International Nuclear Information System (INIS)

    Kovarik, Z.; Katalinic, M.; Sinko, G.

    2009-01-01

    The phosphorylation of the serine hydroxyl group in the active site of acetylcholinesterase (AChE) inactivates this essential enzyme in neurotransmission. Its related enzyme butyrylcholinesterase (BChE) also interacts with organophosphorus compounds (OP) scavenging anti-cholinesterase agents and protects synaptic AChE from inhibition. Oximes are reactivators of AChE phosphorylated by OP including insecticides and nerve agents. The effectiveness of oxime-assisted reactivation is primarily attributed to the nucleophilic displacement rate of organophosphate, but efficiency varies with the structure of the bound organophosphate, the structure of the oxime as well as rates of several other cholinesterase's reactions. Besides reactivating cholinesterases, oximes also reversibly inhibit both cholinesterases and protect them from phosphorylation by OP. We tested oximes varying in the type of ring (pyridinium and/or imidazolium), the length and type of the linker between rings, and in the position of the oxime group on the ring to find more effective oximes to reactivate tabun-inhibited human erythrocyte AChE and plasma BChE. Herein we bring an overview of in vitro interactions of native and tabun-inhibited AChE and BChE with oximes together with conformational analysis of the oximes relating molecular properties to their reactivation potency.(author)

  8. Reconsideration of the indication of Ga-67 scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Takanashi, Toshiyasu; Komatani, Akio; Yamaguchi, Koichi (Yamagata Univ. (Japan))

    1984-11-01

    In order to establish proper indication of Ga-67 scintigraphy, its actual utilization in our hospital was reviewed. Although a large number of Ga-67 scintigraphy over 500 cases a year had been done, the clinical efficacy was found in limited conditions such as small cell carcinoma of the lung, malignant lymphoma, anaplastic carcinoma of the thyroid and abscess. In the other conditions, Ga-67 scintigraphy had little significance clinically and was not effective for seeking metastasis. Based on such situations, we emphasized that the indication of Ga-67 scintigraphy should be more limited under the better understanding of its characteristics.

  9. Gamma irradiation of cholestenone oximes

    International Nuclear Information System (INIS)

    Uenseren, Envare.

    1976-01-01

    Irradiation of cholest-4-en-3-one and cholest-5-en-3-one oximes with cobalt-60 gamma-rays in different solvents at different doses gave a mixture of products from which ketones corresponding to the starting oximes, Beckmann type rearrangement products, and some other radiolysis products have been isolated and identified

  10. Diagnostic value of static and dynamic scintigraphy in diagnosis of acute respiratory distress syndrome in the course of sepsis. Part 1. Lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Jurgilewicz, D.; Rogowski, F.; Malinowska, L.

    1997-01-01

    One of the most important complication of sepsis is acute respiratory distress syndrome (ARDS). Diagnosis of the illness is mainly based on chest radiography and gasometric parameters of the blood. The aim of the study was to estimate the diagnostic usefulness of lung perfusion scintigraphy in early detection of blood flow and gas-exchange abnormalities in patients with ARDS in the course of sepsis. Scintigraphic studies of 12 patients in critical condition were performed, using Hungarian planar gamma camera type MB9200 and human albumin microspheres labelled with 99m Tc. Perfusion scans of patients with ARDS demonstrated blurring outlines and abundant diffuse foci of lack of radioactivity in both lungs and quantitative analysis indicated relative increase of Tc99m-MSA accumulation in upper zones of both lungs. Scans of suffering from sepsis were similar to control one. The course of the studies showed that scintigraphic methods could be safely use in patients with sepsis and ARDS and may be helpful in the early diagnosis of ARDS in the septic patients. (author)

  11. Technetium-99m-hexakis-2-methoxyisobutylisonitrile scintigraphy and multidrug resistance-related protein expression in human primary lung cancer

    International Nuclear Information System (INIS)

    Duan Xiaoyi; Wang Jiansheng; Liu Min; Guo Youmin

    2008-01-01

    The occurrence of multidrug resistance (MDR) is a major cause of resistance to chemotherapeutic agents in patients with lung cancer, in part owing to the overexpression of MDR-related proteins. Technetium-99m-hexakis-2-methoxyisobutylisonitrile ( 99m Tc-MIBI) has been shown to be a substrate for some MDR-related proteins. The aim of this study is to evaluate the role of 99m Tc-MIBI scintigraphy for functional imaging of MDR-related protein phenotypes. To determine the correlation between 99m Tc-MIBI scintigraphy and the expression level of P-glycoprotein (Pgp), multidrug-resistance protein (MRP), and glutathione-S-transferase Pi (GSTπ), 26 patients (17 men and 9 women, median age 57.5 years) with primary lung cancer were investigated. Following intravenous administration of 925 MBq 99m Tc-MIBI, single-photon emission computed tomography (SPECT) and computed tomography (CT) were performed at 15 min and 2 h. On the basis of the fused images, tumor to background (T/B) ratio of both early and delayed images, and washout rate (WR%) of 99m Tc-MIBI were calculated. The immunohistochemical staining of Pgp, MRP, and GSTπ was performed, and the expression level was semiquantitated using a pathoimage analysis system. The imaging results were compared with the status of Pgp, MRP, and GSTπ expression. The WR% of 99m Tc-MIBI showed a significant positive correlation with Pgp expression (r=0.560, P=0.003), as no correlation was observed between WR% and MRP or GSTπ (r=0.354, P=0.076; r=0.324, P=0.106). Neither early T/B nor delayed T/B correlated with the expression level of Pgp, MRP, and GSTπ. WR%, Pgp, and GSTπ expression showed significant differences between squamous cell carcinoma (group A) and adenocarcinoma (group B). There was no significant difference among Pgp, MRP, and GSTπ expression levels in any cases (P>0.05). Our data confirmed that 99m Tc-MIBI scintigraphy is useful for determining the MDR caused by Pgp in patients with primary lung cancer. (author)

  12. Position of lung scintigraphy in emergency diagnosis and therapeutic indications in cases of severe pulmonary embolism

    International Nuclear Information System (INIS)

    Torquat, Sabine de.

    1975-01-01

    The position of lung scintigraphy in diagnostic strategy is discussed. This technique appears to afford the key examination in severe pulmonary embolism because of its qualities, which are: - speed of execution, - absolute harmlessness, - diagnostic safety. Taking these points in order: - speed of execution is ensured by the very rapid uptake of I 131-labelled albumin macroaggregates (usable immediately) and the existence of the gamma camera; - harmlessness of the examination by the use of non-allergenic radioactive tracers and doses not significantly restricting the vascular bed still perfused; whichever of the two possible techniques is employed (scanner and gamma camera) the examination can always be practised without getting the patient out of bed, which avoids the risk of clot migration due to movement; - certainty of the result by the fact that in the event of a surgical indication the circulation cut-off image is spectacular and obvious in fact a lung amputation image must be equal to or greater than 50% of the pulmonary field before an operation is decided upon all other images remaining within the scope of a hypocoagulant treatment. A study was carried out in a cardio-vascular surgery department on 28 patients hospitalised with a possible view to embolectomy. Lung scintigraphy allows a quick exploration of the minor circulation. In the special clinical situation of the patients, for whom the advisability of an embolectomy is discussed, the scintigraphic examination provides the key: if normal it eliminates the diagnosis absolutely; if not it reveals without extra risk the spectacular obliterations of the vascular bed on which any therapeutic decision, medical or surgical is based [fr

  13. Clinical implications of increased lung uptake of 201Tl during exercise scintigraphy 2 weeks after myocardial infarction

    International Nuclear Information System (INIS)

    Gibson, R.S.; Watson, D.D.; Carabello, B.A.; Holt, N.D.; Beller, G.A.

    1982-01-01

    To determine the prevalence and clinical significance of increased lung 201 Tl uptake during submaximal exercise myocardial scintigraphy performed 2 weeks after acute myocardial infarction, 61 patients underwent submaximal exercise testing (target heart rate, 120 beats/min), multigated blood pool imaging at rest and coronary angiography before hospital discharge. Thallium lung uptake on the initial anterior projection image was graded qualitatively by comparing the intensity of 201 Tl activity in the lungs with that in the mediastinum. In 39 patients (64 percent), it was normal (equal to mediastinal activity) and in 22 (36 percent), it was increased (greater than mediastinal activity). Compared with patients with normal lung uptake, those with increased uptake had a greater prevalence of prior infarction (13 versus 36 percent, probability [p] less than 0.05), less global cardiac reserve as assessed by the four level New York Heart Association classification (p less than 0.05), more advanced Killip class in the coronary care unit (p less than 0.05), a higher Norris coronary prognostic index (2.6 +/- 1.9 versus 4.6 +/- 2.3 [mean +/- standard deviation], p less than 0.01), failure to achieve the target heart rate because of dyspnea, fatigue or angina (36 versus 86 percent, p less than 0.01), a greater prevalence of exercise-induced S-T segment depression (18 versus 45 percent, p less than 0.05), a greater number of anterior 201 Tl myocardial defects (p less than 0.05); a lower radionuclide ejection fraction at rest (50.4 +/- 6.1 versus 39.6 +/- 9.3 percent, p less than 0.01) and a greater number of asynergic left ventricular segments (p less than 0.05). Thus, the occurrence of increased lung 201 Tl uptake during submaximal exercise scintigraphy in the early postinfarction period is frequent and appears to be a marker of severe and functionally more important coronary artery disease associated with left ventricular dysfunction

  14. Nucleomedical diagnosis of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Yasuhiko [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1982-06-01

    /sup 67/Ga citrate is most often used in the diagnosis of lung cancer. As judged from reported cases, the accuracy rate was 90%, with a false negative rate being about 5%. Lung ventilation and blood flow scintigraphy are valuable in assessing the degree of damage to lung function and the therapeutic effect rather than in finding lung cancer. In aerosol scintigraphy, sup(99m)Tc labelled aerosols with different particle size depending on the purpose of diagnosis are used; the large particles deposit at the center of the trachea and small size aerosols on the periphery. Aerosol-inhaled scintigraphy is highly valuable for the diagnosis of hilus lung cancer. sup(99m)Tc methylene diphosphate is used in bone scintigraphy to detect bone metastasis. But it sometimes gives false positive results such as in the case of senile bone changes. Another valuable method of diagnosis is emission CT by which various substances having affinity for the tumor can be detected by labelling them with a proton emitting nuclear species such as 11 C, /sup 13/N, /sup 15/O and /sup 18/F. Some cases of lung cancer, and the radionuclide methods used in the diagnosis are shown.

  15. Cutaneous exposure to vesicant phosgene oxime: Acute effects on the skin and systemic toxicity

    International Nuclear Information System (INIS)

    Tewari-Singh, Neera; Goswami, Dinesh G; Kant, Rama; Croutch, Claire R; Casillas, Robert P; Orlicky, David J; Agarwal, Rajesh

    2017-01-01

    Phosgene Oxime (CX), an urticant or nettle agent categorized as a vesicant, is a potential chemical warfare and terrorist weapon. Its exposure can result in widespread and devastating effects including high mortality due to its fast penetration and ability to cause immediate severe cutaneous injury. It is one of the least studied chemical warfare agents with no effective therapy available. Thus, our goal was to examine the acute effects of CX following its cutaneous exposure in SKH-1 hairless mice to help establish a relevant injury model. Results from our study show that topical cutaneous exposure to CX vapor causes blanching of exposed skin with an erythematous ring, necrosis, edema, mild urticaria and erythema within minutes after exposure out to 8 h post-exposure. These clinical skin manifestations were accompanied with increases in skin thickness, apoptotic cell death, mast cell degranulation, myeloperoxidase activity indicating neutrophil infiltration, p53 phosphorylation and accumulation, and an increase in COX-2 and TNFα levels. Topical CX-exposure also resulted in the dilatation of the peripheral vessels with a robust increase in RBCs in vessels of the liver, spleen, kidney, lungs and heart tissues. These events could cause a drop in blood pressure leading to shock, hypoxia and death. Together, this is the first report on effects of CX cutaneous exposure, which could help design further comprehensive studies evaluating the acute and chronic skin injuries from CX topical exposure and elucidate the related mechanism of action to aid in the identification of therapeutic targets and mitigation of injury. - Highlights: • Phosgene oxime cutaneous exposure causes skin blanching, edema and urticaria. • Penetration of phosgene oxime causes dilation of vasculature in internal organs. • Mast cells could play an important role in phosgene oxime-induced skin injury. • Phosgene oxime could induce low blood pressure and hypoxia leading to mortality. • Data is

  16. Cutaneous exposure to vesicant phosgene oxime: Acute effects on the skin and systemic toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Tewari-Singh, Neera, E-mail: Neera.tewari-singh@ucdenver.edu [Department of Pharmaceutical Sciences, Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Anschutz Medical Campus, Aurora, CO 80045 (United States); Goswami, Dinesh G; Kant, Rama [Department of Pharmaceutical Sciences, Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Anschutz Medical Campus, Aurora, CO 80045 (United States); Croutch, Claire R; Casillas, Robert P [MRIGlobal, Kansas City, MO 64110 (United States); Orlicky, David J [Department of Pathology, School of Medicine, University of Colorado Anschutz Medical Campus, Aurora, CO 80045 (United States); Agarwal, Rajesh [Department of Pharmaceutical Sciences, Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Anschutz Medical Campus, Aurora, CO 80045 (United States)

    2017-02-15

    Phosgene Oxime (CX), an urticant or nettle agent categorized as a vesicant, is a potential chemical warfare and terrorist weapon. Its exposure can result in widespread and devastating effects including high mortality due to its fast penetration and ability to cause immediate severe cutaneous injury. It is one of the least studied chemical warfare agents with no effective therapy available. Thus, our goal was to examine the acute effects of CX following its cutaneous exposure in SKH-1 hairless mice to help establish a relevant injury model. Results from our study show that topical cutaneous exposure to CX vapor causes blanching of exposed skin with an erythematous ring, necrosis, edema, mild urticaria and erythema within minutes after exposure out to 8 h post-exposure. These clinical skin manifestations were accompanied with increases in skin thickness, apoptotic cell death, mast cell degranulation, myeloperoxidase activity indicating neutrophil infiltration, p53 phosphorylation and accumulation, and an increase in COX-2 and TNFα levels. Topical CX-exposure also resulted in the dilatation of the peripheral vessels with a robust increase in RBCs in vessels of the liver, spleen, kidney, lungs and heart tissues. These events could cause a drop in blood pressure leading to shock, hypoxia and death. Together, this is the first report on effects of CX cutaneous exposure, which could help design further comprehensive studies evaluating the acute and chronic skin injuries from CX topical exposure and elucidate the related mechanism of action to aid in the identification of therapeutic targets and mitigation of injury. - Highlights: • Phosgene oxime cutaneous exposure causes skin blanching, edema and urticaria. • Penetration of phosgene oxime causes dilation of vasculature in internal organs. • Mast cells could play an important role in phosgene oxime-induced skin injury. • Phosgene oxime could induce low blood pressure and hypoxia leading to mortality. • Data is

  17. Bronchial and pulmonary scintigraphy with radioactively marked aerosols

    International Nuclear Information System (INIS)

    Wuerstle, T.

    1982-01-01

    In 97 patients with bronchitis, bronchial asthma, tuberculosis, sarcoidosis, pneumoconiosis, or tumors the mucociliary clearance and/or deposit pattern after inhalation of radioactively marked aerosols (1 mCi 99m Tc sulfur colloid) was studied. Normal values of the mucociliary 30 min. clearance for the central bronchial/lung periphery are 21%/15%. There was a decreased clearance with bronchitis (11/8%), bronchial asthma, emphysema, tuberculosis, sarcoidosis, trachiobronchial amyloidosis, pleural scarring or interstitial pneumona. Increased clearance (29/19%) was shown with pneumoconiosis. The correlation of deposit pattern and disease, for example, bronchitis, bronchial asthma, bullous emphysema, pleural scarring, partial lung resection, bronchopneumonia, or bronchial restriction, is described. In comparison of aerosol scintigraphy to perfusion scintigraphy and ventilation with gaseous xenon, the aerosol scintigraphy is superior to xenon for certain indications. The aerosol particles, which are larger in comparison to xenon, settle easier by obstructions or flow variations and thereby give better clinical indications of regional differences. (orig.) [de

  18. A Highly Efficient Catalyst for Oxime Ligation and Hydrazone-Oxime Exchange Suitable for Bioconjugation

    OpenAIRE

    Rashidian, Mohammad; Mahmoodi, Mohammad M.; Shah, Rachit; Dozier, Jonathan K.; Wagner, Carston R.; Distefano, Mark D.

    2013-01-01

    Imine-based reactions are useful for a wide range of bioconjugation applications. Although aniline is known to catalyze the oxime ligation reaction under physiological conditions, it suffers from slow reaction kinetics, specifically when a ketone is being used or when hydrazone-oxime exchange is performed. Here, we report on the discovery of a new catalyst that is up to 15 times more efficient than aniline. That catalyst, m-phenylenediamine (mPDA), was initially used to analyze the kinetics o...

  19. The Preparation and Intramolecular Radical Cyclisation Reactions of Chiral Oxime Ethers

    Directory of Open Access Journals (Sweden)

    Booth Susan E.

    1998-01-01

    Full Text Available Chiral oxime ether 2 and Oxime ester 4 have been prepared by alkylation and esterification of the oxime 1. Racemic hydroxylamine 6 and chiral hydroxylamine 10 have been synthesised from N-hydroxysuccinimide and the corresponding alcohol in the presence of diethylazodicarboxylate, the two products were converted into the oxime ethers 7 and 11 respectively. The intramolecular radical cyclisation reactions of these oxime ethers and esters has been studied, successful reaction was observed to produce alkyl hydroxylamines 3, 8 and 12.

  20. Indications for scintigraphy with 67Ga

    International Nuclear Information System (INIS)

    Plechl, S.C.; Berges, G.; Blut, J.; Bohle, H.; Gessat, C.; Hethey, B.; Linneborn, G.; Ostermann, W.; Prack, G.; Scheitza, B.

    1976-01-01

    The validity and exactness of 67 Ga scintigraphy was tested in more than 70 patients by a comparison with clinical, radiological and histological findings as well as with scintigraphs obtained with other nuclides. It was found that 67 Ga scintigraphy is a good and often even a vital supplementation to the other methods. Its main field of application, according to the authors' obervations, is the differential diagnosis of three-dimensional changes in the thorax region, in particular the diagnosis of malignant tumours of the lungs in combination with X-ray examinations. Furthermore, 67 Ga may be of use in localization diagnoses of non-malignant changes, e.g. abscesses. 67 Ga scintigraphy, which is non-hazardous and does not involve discomfort to the patients, appears to be particularly useful for course control after surgical treatment of breast cancer and for early diagnoses of metastases, provided that examination starts early enough and is repeated at regular intervals, not only in the soft parts but also in the skeleton. The question whether 67 Ga scintigraphy may be a substitute for scintigraphy with other nuclides in these fields still remains to be solved. (orig.) [de

  1. Synthesis, spectra and X-ray crystallography of dipyridin-2-ylmethanone oxime and its CuX2(oxime)2 complexes: Thermal, Hirshfeld surface and DFT analysis

    Science.gov (United States)

    Warad, Ismail; Abdoh, Muneer; Al Ali, Anas; Shivalingegowda, Naveen; Kumara, Karthik; Zarrouk, Abdelkader; Lokanath, Neartur Krishnappagowda

    2018-02-01

    Dipyridin-2-ylmethanone oxime (C11H9N3O), was prepared using di-2-pyridyl ketone. The oxime ligand and its neutral CuX2 (oxime)2 (X = Cl or Br) complexes have been identified with the aid of several spectroscopic techniques such as: IR, EI-MS, EA, UV-visible, TG, 1H-NMR and finally the structure of the free oxime ligand was confirmed by X-ray diffraction studies. The oxime crystallizes in the monoclinic space group P21/c, with cell parameters a = 8.8811 (8) Å, b = 10.6362 (8) Å, c = 11.2050 (8) Å, β = 109.085 (4) º, V = 1000.26 (14) Å3 and Z = 4. The molecular conformation is stabilized by a strong intramolecular Osbnd H⋯N hydrogen bonding between the hydroxyl group of the oxime moiety and the nitrogen of the pyridine ring. Since the oxime structure was solved by XRD, the ligand structure parameters like bond length and angles were compared to the DFT computed one, the UV-visible to TD-SCF and Hirshfeld surface to MEP analysis.

  2. AIDS-related Kaposi sarcoma: findings on thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Lee, V.W.; Rosen, M.P.; Baum, A.; Cohen, S.E.; Cooley, T.P.; Liebman, H.A.

    1988-01-01

    No simple, noninvasive method is available for evaluating extracutaneous Kaposi sarcoma in AIDS patients or for following the tumor's response to treatment. We report our preliminary experience with thallium-201 scintigraphy in nine AIDS patients with proved Kaposi sarcoma. Eight of the nine had abnormal uptake of the radionuclide in skin, lymph nodes, oral cavity, vagina, and lungs. Only four of the nine had cutaneous Kaposi sarcoma at the time of scanning. All cutaneous and mucosal lesions were thallium avid. Two of the six patients with thallium-avid nodes underwent nodal biopsy. Both biopsies confirmed the diagnosis of Kaposi sarcoma. Cutaneous Kaposi sarcoma developed later in one of these patients, showing the efficacy of thallium scintigraphy for the early detection of extracutaneous lesions. These preliminary results show thallium avidity in Kaposi sarcoma involving the skin and various extracutaneous sites (lymph nodes, lung, mucosa, and vagina). Thallium scintigraphy is a potentially useful procedure for detecting extracutaneous Kaposi sarcoma in AIDS patients

  3. Reaction of the oximes of aliphatic aldehydes and ketones with alkoxyethenes

    International Nuclear Information System (INIS)

    Voronkov, M.G.; Keiko, N.A.; Shuvashev, Yu.A.; Kalikhman, I.D.; Keiko, V.V.

    1987-01-01

    In the reaction of acetone oxime with alkyl vinyl ethers in the presence of zinc chloride variable amounts of acetone 0,0'-(2-propylidene)dioxime, acetaldehyde dialkyl acetal, acetaldehyde 0-(1-alkoxyethyl)oxide, and acetone 0-(1-alkoxy-1-methylethyl)oxime, depending on the reaction conditions, are formed in addition to acetone 0-(1-alkoxyethyl)oxime (the initial addition product). In the reaction of acetaldehyde oxime with alkyl vinyl ethers in the presence of zinc chloride acetaldehyde oxime with alkyl vinyl ethers in the presence of zinc chloride acetaldehyde dialkyl acetal was isolated in addition to acetaldehyde 0-(1-alkoxyethyl)oxime. A mechanism for the formation of the obtained compounds is proposed

  4. A structure-activity analysis of the variation in oxime efficacy against nerve agents

    International Nuclear Information System (INIS)

    Maxwell, Donald M.; Koplovitz, Irwin; Worek, Franz; Sweeney, Richard E.

    2008-01-01

    A structure-activity analysis was used to evaluate the variation in oxime efficacy of 2-PAM, obidoxime, HI-6 and ICD585 against nerve agents. In vivo oxime protection and in vitro oxime reactivation were used as indicators of oxime efficacy against VX, sarin, VR and cyclosarin. Analysis of in vivo oxime protection was conducted with oxime protective ratios (PR) from guinea pigs receiving oxime and atropine therapy after sc administration of nerve agent. Analysis of in vitro reactivation was conducted with second-order rate contants (k r2 ) for oxime reactivation of agent-inhibited acetylcholinesterase (AChE) from guinea pig erythrocytes. In vivo oxime PR and in vitro k r2 decreased as the volume of the alkylmethylphosphonate moiety of nerve agents increased from VX to cyclosarin. This effect was greater with 2-PAM and obidoxime (> 14-fold decrease in PR) than with HI-6 and ICD585 ( r2 as the volume of the agent moiety conjugated to AChE increased was consistent with a steric hindrance mechanism. Linear regression of log (PR-1) against log (k r2 · [oxime dose]) produced two offset parallel regression lines that delineated a significant difference between the coupling of oxime reactivation and oxime protection for HI-6 and ICD585 compared to 2-PAM and obidoxime. HI-6 and ICD585 appeared to be 6.8-fold more effective than 2-PAM and obidoxime at coupling oxime reactivation to oxime protection, which suggested that the isonicotinamide group that is common to both of these oximes, but absent from 2-PAM and obidoxime, is important for oxime efficacy

  5. Diagnosis of pyogenic pelvic inflammatory diseases by {sup 99m}Tc-HMPAO leucocyte scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Rachinsky, I.; Boguslavsky, L.; Golan, H.; Lantsberg, S. [Department of Nuclear Medicine, Ben-Gurion Univ. of the Negev (Israel); Goldstein, D.; Pak, I.; Katz, M. [Department of Obstetrics and Gynecology, Ben-Gurion Univ. of the Negev, Beer-Sheva (Israel)

    2000-12-01

    Pelvic inflammatory disease (PID) is one of the major health problems of women of child-bearing age. Among the most serious complications of PID is the formation of a tubo-ovarian abscess (TOA). Early diagnosis of this condition may prevent serious surgical complications such as peritonitis and sepsis, which may be fatal. The purpose of this study was to investigate the efficacy of technetium-99m hexamethylpropylene amine oxime (HMPAO) leucocyte scintigraphy in the diagnosis of TOA. Twenty women with high clinical suspicion of TOA underwent {sup 99m}Tc-HMPAO leucocyte scintigraphy. The labelling of leucocytes with {sup 99m}Tc-HMPAO was performed according to a standard protocol. Scans were obtained at 1, 3 and 24 h following the injection of the labelled leucocytes. In eight cases the early and/or late scan was positive, in 11 cases it was negative, and in one case of ovarian cyst torsion, confirmed by laparoscopy, it showed slight uptake in the capsule of the cyst (false-positive). The sensitivity of {sup 99m}Tc-HMPAO leucocyte scintigraphy was 100%, specificity 91.6%, positive predictive value 89%, negative predictive value 100% and overall accuracy 95%. It is concluded that leucocyte scintigraphy is a non-invasive, safe, physiological and accurate procedure for the diagnosis of TOA. The 24-h scan is crucial, since in some cases the abscess was not clearly visualized on the early scan. Leucocyte scintigraphy may reduce the need for CT, diagnostic laparoscopy and unnecessary invasive surgical procedures. (orig.)

  6. Establishment of an experimental human lung adenocarcinoma cell line SPC-A-1BM with high bone metastases potency by 99mTc-MDP bone scintigraphy

    International Nuclear Information System (INIS)

    Yang Shunfang; Dong Qianggang; Yao Ming; Shi Meiping; Ye Jianding; Zhao Langxiang; Su Jianzhong; Gu Weiyong; Xie Wenhui; Wang Kankan; Du Yanzhi; Li Yao; Huang Yan

    2009-01-01

    Background: Bone metastasis is one of the most common clinical phenomena of late stage lung cancer. A major impediment to understanding the pathogenesis of bone metastasis has been the lack of an appropriate animal and cell model. This study aims to establish human lung adenocarcinoma cell line with highly bone metastases potency with 99m Tc-MDP bone scintigraphy. Methods: The human lung adenocarcinoma cancer cells SPC-A-1 were injected into the left cardiac ventricle of NIH-Beige-Nude-XID (NIH-BNX) immunodeficient mice. The metastatic lesions of tumor-bearing mice were imaged with 99m Tc-MDP bone scintigraphy on a Siemens multi-single photon emission computed tomography. Pinhole images were acquired on a GZ-B conventional gamma camera with a self-designed pinhole collimator. The mice with bone metastasis were sacrificed under deep anesthesia, and the lesions were resected. Bone metastatic cancer cells in the resected lesions were subjected for culture and then reinoculated into the NIH-BNX mice through left cardiac ventricle. The process was repeated for eight cycles to obtain a novel cell subline SPC-A-1BM. Real-time polymerase chain reaction (PCR) was used to compare the gene expression differences in the parental and SPC-A-1BM cells. Results: The bone metastasis sites were successfully revealed by bone scintigraphy. The established bone metastasis cell line SPC-A-1BM had a high potential to metastasize in bone, including mandible, humerus, thoracic vertebra, lumbar, femur, patella, ilium and cartilage rib. The expression level of vascular endothelial growth factor gene family, Bcl-2 and cell adhesion-related genes ECM1, ESM1, AF1Q, SERPINE2 and FN1 were examined. Gene expression difference was found between parental and bone-seeking metastasis cell SPC-A-1BM, which indicates SPC-A-1BM has metastatic capacity vs. its parental cells. Conclusion: SPC-A-1BM is a bone-seeking metastasis human lung adenocarcinoma cell line. Bone scintigraphy may be used as an

  7. Lung ventilation-perfusion scintigraphy in children on long-term parenteral nutrition

    Energy Technology Data Exchange (ETDEWEB)

    Pifarre, Paloma; Roca, Isabel [Universitat Autonoma de Barcelona, Department of Nuclear Medicine, Hospital de la Vall d' Hebron, Barcelona (Spain); Irastorza, Inaki; Hill, Susan [Great Ormond Street Hospital, Department of Gastroenterology, London (United Kingdom); Simo, Marc [Instituto Universitario Dexeus, Department of Nuclear Medicine, Barcelona (Spain); Biassoni, Lorenzo; Gordon, Isky [Great Ormond Street Hospital, Department of Nuclear Medicine, London (United Kingdom)

    2009-06-15

    Pulmonary emboli (PE) are one of the major complications associated with total parenteral nutrition (TPN). Ventilation-perfusion scintigraphy (V/Q) remains the most used test for the diagnosis of PE and follow-up of patients on TPN. The aim of our study was to demonstrate the high prevalence of undiagnosed PE in children on TPN. The medical and imaging files of 64 patients on TPN who underwent V/Q examinations covering the period of 1986-2004 were reviewed. Children were aged between 3.18 months and 21.6 years. TPN was started at birth (range 0-15 years). All children had a normal chest radiograph and no symptoms at the time of the V/Q scan. A comparative analysis between the prevalence of PE and risk factors number of days per week with lipophilic content of the TPN, bowel inflammation and thrombophilic factors (protein C and S) was performed. Of the 64 patients, 25 (39%) had an abnormal V/Q scan. A total of 29 PE episodes were diagnosed in all patients. Two children had three episodes of PE. The median age at PE diagnosis was 4.6 years. In 17 patients (68%) diagnosis was achieved on the first V/Q scan performed. PE was bilateral in 56% and unilateral in 44%. PE was the main cause of 2 out 15 recorded deaths. All risk factors were associated with an increase in PE prevalence by statistical analysis. PE is underdiagnosed in children on long-term TPN. Lung V/Q scintigraphy is useful in the diagnosis of PE in children with a low pretest probability. (orig.)

  8. Functional evaluation of lung by Xe-133 lung ventilation scintigraphy before and after lung volume reduction surgery (LVRS) in patients with pulmonary emphysema

    International Nuclear Information System (INIS)

    Kurose, Taichi; Okumura, Yoshihiro; Sato, Shuhei

    2004-01-01

    We evaluated the respiratory functions of patients with pulmonary emphysema who underwent lung volume reduction surgery (LVRS) by the mean transit time (MTT) with Xe-133 lung ventilation scintigraphy, forced expiration volume in 1 sec (FEV1.0), residual volume (RV), distance walked in 6 min (6-min walk), and the Hugh-Jones classification (H-J classification) before and after LVRS. In 69 patients with pulmonary emphysema (62 men, 7 women; age range, 47-75 years; mean age, 65.4 years±6.1, preoperative H-J classification, III (two were II)-V) who underwent LVRS, all preoperative and postoperative parameters (MTT 3 weeks after LVRS and the others 3 months after LVRS) were judged statistically by the Wilcoxon signed-ranks test and Odds ratio. Every postoperative parameter was improved with a significant difference (P<0.05) compared to preoperative parameters. MTT at 3 weeks after LVRS was not associated with %FEV1.0 and the H-J classification at 3 months after LVRS, but was associated with RV and a 6-min walk at 3 months after LVRS. MTT was useful for the clinical evaluation of aerobic capability after LVRS. (author)

  9. Using quantitative breath sound measurements to predict lung function following resection

    Directory of Open Access Journals (Sweden)

    Keus Leendert

    2010-10-01

    Full Text Available Abstract Background Predicting postoperative lung function is important for estimating the risk of complications and long-term disability after pulmonary resection. We investigated the capability of vibration response imaging (VRI as an alternative to lung scintigraphy for prediction of postoperative lung function in patients with intrathoracic malignancies. Methods Eighty-five patients with intrathoracic malignancies, considered candidates for lung resection, were prospectively studied. The projected postoperative (ppo lung function was calculated using: perfusion scintigraphy, ventilation scintigraphy, and VRI. Two sets of assessments made: one for lobectomy and one for pneumonectomy. Clinical concordance was defined as both methods agreeing that either a patient was or was not a surgical candidate based on a ppoFEV1% and ppoDLCO% > 40%. Results Limits of agreement between scintigraphy and VRI for ppo following lobectomy were -16.47% to 15.08% (mean difference = -0.70%;95%CI = -2.51% to 1.12% and for pneumonectomy were -23.79% to 19.04% (mean difference = -2.38%;95%CI = -4.69% to -0.07%. Clinical concordance between VRI and scintigraphy was 73% for pneumonectomy and 98% for lobectomy. For patients who had surgery and postoperative lung function testing (n = 31, ppoFEV1% using scintigraphic methods correlated with measured postoperative values better than projections using VRI, (adjusted R2 = 0.32 scintigraphy; 0.20 VRI, however the difference between methods failed to reach statistical significance. Limits of agreement between measured FEV1% postoperatively and ppoFEV1% based on perfusion scintigraphy were -16.86% to 23.73% (mean difference = 3.44%;95%CI = -0.29% to 7.16%; based on VRI were -19.56% to 28.99% (mean difference = 4.72%;95%CI = 0.27% to 9.17%. Conclusions Further investigation of VRI as an alternative to lung scintigraphy for prediction of postoperative lung function is warranted.

  10. 21 CFR 524.1446 - Milbemycin oxime solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Milbemycin oxime solution. 524.1446 Section 524...) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1446 Milbemycin oxime solution. (a) Specifications. Each tube contains 0.25 milliliter of a 0.1 percent solution...

  11. Diagnostic usefulness of bronchoalveolar lavage, Ga scintigraphy and serum angiotensin converting enzyme activity in granulomatous lung disease

    International Nuclear Information System (INIS)

    Nakano, Ikuo; Tsuneta, Yasuhiro; Terai, Tsugio; Nishimura, Masaharu; Munakata, Mitsuru

    1983-01-01

    Cellular components of bronchoalveolar lavage (BAL) fluid were studied in 26 sarcoid patients, 8 patients with farmer's lung, 10 healthy controls and 10 control patients. The investigations by Ga scintigraphy or transbronchial lung biopsy (TBLB) and measurement of serum angiotensin converting enzyme (SACE) activity were also carried out in 21 sarcoid patients and 8 patients with farmer's lung. 1) Percentage of foamy cells in alveolar ma crophage fraction, percentage of lymphocytes and number of mast cells were increased significantly in BLA fluid from patients with farmer's lung as compared with that from sarcoid patients. Analysis of cellular component of BAL flu id is useful for differential diagnosis of these diseases. 2) Granulomatous lung lesions were frequently observed in specimens obtained by TBLB from patients with sarcoidosis and farmer's lung who showed abnormal Ga uptake in lung. In contrast, there was no significant difference in percentage of lymphocytes in BAL fluid between patients whose pulmonary Ga uptake was positive and those in whom pulmonary Ga uptake was negative. To investigate the mechanism of pulmonary Ga accumulation in granulomatous lung disease, BAL was performed in 2 sarcoid patients and 3 patients with farmer's lung at 48 to 72 hrs after Ga injection. The radioactivity in cell fractions was evaluated at 96 hrs after Ga injection. Most of the radioactivity was found in macrophages, with little in lymphocytes. Pulmonary Ga uptake in patients with sarcoidosis and farmer' s lung reflects granuloma formation or accumulation of activated macrophages in lung, but not the intensity of T-cell alveolitis. 3) Some relationship among SACE, granulomatous lung lesions in specimens obtained by TBLB and abnormal Ga accumulation in lung or hilar lymphnodes in sarcoid patients was observed, suggesting that SACE might reflect the degree of granuloma formation in sarcoidosis. (J.P.N.)

  12. Functionalised Oximes: Emergent Precursors for Carbon-, Nitrogen- and Oxygen-Centred Radicals

    Directory of Open Access Journals (Sweden)

    John C. Walton

    2016-01-01

    Full Text Available Oxime derivatives are easily made, are non-hazardous and have long shelf lives. They contain weak N–O bonds that undergo homolytic scission, on appropriate thermal or photochemical stimulus, to initially release a pair of N- and O-centred radicals. This article reviews the use of these precursors for studying the structures, reactions and kinetics of the released radicals. Two classes have been exploited for radical generation; one comprises carbonyl oximes, principally oxime esters and amides, and the second comprises oxime ethers. Both classes release an iminyl radical together with an equal amount of a second oxygen-centred radical. The O-centred radicals derived from carbonyl oximes decarboxylate giving access to a variety of carbon-centred and nitrogen-centred species. Methods developed for homolytically dissociating the oxime derivatives include UV irradiation, conventional thermal and microwave heating. Photoredox catalytic methods succeed well with specially functionalised oximes and this aspect is also reviewed. Attention is also drawn to the key contributions made by EPR spectroscopy, aided by DFT computations, in elucidating the structures and dynamics of the transient intermediates.

  13. Indications for scintigraphy with /sup 67/Ga

    Energy Technology Data Exchange (ETDEWEB)

    Plechl, S C; Berges, G; Blut, J; Bohle, H; Gessat, C; Hethey, B; Linneborn, G; Ostermann, W; Prack, G; Scheitza, B [Berufsgenossenschaftliche Krankenanstalten Bergmannsheil, Bochum (Germany, F.R.)

    1976-06-01

    The validity and exactness of /sup 67/Ga scintigraphy was tested in more than 70 patients by a comparison with clinical, radiological and histological findings as well as with scintigraphs obtained with other nuclides. It was found that /sup 67/Ga scintigraphy is a good and often even a vital supplementation to the other methods. Its main field of application, according to the authors' obervations, is the differential diagnosis of three-dimensional changes in the thorax region, in particular the diagnosis of malignant tumours of the lungs in combination with X-ray examinations. Furthermore, /sup 67/Ga may be of use in localization diagnoses of non-malignant changes, e.g. abscesses. /sup 67/Ga scintigraphy, which is non-hazardous and does not involve discomfort to the patients, appears to be particularly useful for course control after surgical treatment of breast cancer and for early diagnoses of metastases, provided that examination starts early enough and is repeated at regular intervals, not only in the soft parts but also in the skeleton. The question whether /sup 67/Ga scintigraphy may be a substitute for scintigraphy with other nuclides in these fields still remains to be solved.

  14. α-Diazo oxime ethers for N-heterocycle synthesis.

    Science.gov (United States)

    Choi, Subin; Ha, Sujin; Park, Cheol-Min

    2017-06-01

    This Feature Article introduces the preparation and synthetic utility of α-diazo oxime ethers. α-Oximino carbenes are useful synthons for N-heterocycles, and can be easily prepared from α-diazo oxime ethers as precursors. We begin with the preparation of α-diazo oxime ethers and their application in [3+2] cycloaddition. It turns out that the nature of metals bound to carbenes plays a crucial role in modulating the reactivity of α-oximino carbenes, in which copper carbenes smoothly react with enamines, whereas the less reactive enol ethers and nitriles require gold carbenes. In Section 3.2, a discussion on N-O and C-H bond activation is presented. Carbenes derived from diazo oxime ethers show unique reactivity towards N-O and C-H bond activation, in which the proximity of the two functionalities, carbene and oxime ether, dictates the preferred reaction pathways toward pyridines, pyrroles, and 2H-azirines. In Section 3.3, the development of tandem reactions based on α-diazo oxime ethers is discussed. The nature of carbenes in which whether free carbenes or metal complexes are involved dissects the pathway and forms different types of 2H-azirines. The 2H-azirine formation turned out to be an excellent platform for the tandem synthesis of N-heterocycles including pyrroles and pyridines. In the last section, we describe the electrophilic activation of 2H-azirines with vinyl carbenes and oximino carbenes. The resulting azirinium species undergo rapid ring expansion rearrangements to form pyridines and pyrazines.

  15. A comparison of the neuroprotective efficacy of individual oxime (HI-6) and combinations of oximes (HI-6+trimedoxime, HI-6+K203) in soman-poisoned rats.

    Science.gov (United States)

    Kassa, Jiri; Karasova, Jana Zdarova; Tesarova, Sandra

    2011-07-01

    The ability of two combinations of oximes (HI-6+trimedoxime, HI-6+K203) to reduce soman-induced acute neurotoxic signs and symptoms was compared with the neuroprotective efficacy of the oxime HI-6 alone, using a functional observational battery. Soman-induced neurotoxicity and the neuroprotective effects of HI-6 alone and HI-6 combined with trimedoxime or K203 in rats poisoned with soman at a sublethal dose (90 μg/kg intramuscularly, i.m.; 80% of LD₅₀ value) were monitored by the functional observational battery at 24 hours following soman administration. The results indicate that both tested oxime mixtures combined with atropine were able to allow soman-poisoned rats to survive 24 hours following soman challenge, while 4 nontreated soman-poisoned rats and 1 soman-poisoned rat treated with oxime HI-6 alone combined with atropine died within 24 hours following soman poisoning. While the oxime HI-6 alone combined with atropine treatment was able to eliminate a few soman-induced neurotoxic signs and symptoms, both oxime mixtures showed higher neuroprotective efficacy in soman-poisoned rats. Especially, the combination of HI-6 with trimedoxime was able to eliminate most soman-induced neurotoxic signs and symptoms and markedly reduce acute neurotoxicity of soman in rats. Thus, both tested mixtures of oximes combined with atropine were able to increase the neuroprotective effectiveness of antidotal treatment of acute soman poisonings, compared to the individual oxime.

  16. Less common patterns of reduction of some oximes

    Czech Academy of Sciences Publication Activity Database

    Celik, H.; Ludvík, Jiří; Zuman, P.

    2007-01-01

    Roč. 52, č. 5 (2007), s. 1990-2000 ISSN 0013-4686 R&D Projects: GA MŠk 1P05ME785 Institutional research plan: CEZ:AV0Z40400503 Keywords : polarography * benzaldehyde oximes * acetophenone oximes * isomeric monoximes Subject RIV: CG - Electrochemistry Impact factor: 2.848, year: 2007

  17. Simple, Efficient and Green Synthesis of Oximes under Ultrasound ...

    African Journals Online (AJOL)

    NICO

    Faculty of Chemistry, Bu-Ali Sina University, Hamadan 65174, Iran. ... The condensation of aldehydes and ketones with hydroxylamine hydrochloride gives oximes in 81–95 ... Oximes are important in organic synthesis not only for protec-.

  18. A Structure-Activity Analysis of the Variation in Oxime Efficacy Against Nerve Agents

    Science.gov (United States)

    2008-01-01

    cyclosarin. Analysis of in vivo oxime protection was conducted with oxime protective ratios (PR) from guinea pigs receiving oxime and atropine therapy ...in our study confirmed previous assessments that oxime protection varies drama - tically against different military nerve agents (Aas, 2003; Dawson... therapy ofacutepoisonings inducedbyanti-cholinesterase neuroparalytic substances. In:Monov, A., Dishovsky, C. (Eds.), Medical Aspects of Chemical and

  19. Adsorption equilibrium of uranium from seawater on chelating resin containing amide oxime group

    International Nuclear Information System (INIS)

    Hori, Takahiro; Saito, Kyoichi; Furusaki, Shintaro; Sugo, Takanobu; Okamoto, Jiro.

    1987-01-01

    Chelating resins containing amide oxime group were synthesized by radiation-induced graft polymerization. The amount of the amide oxime groups was controlled below about 0.1 mol per kg of base polymer. The adsorption equilibrium of uranium from seawater on this resin was investigated. It was suggested that two neighboring amide oxime groups on the grafted chain captured one uranyl ion, and that single amide oxime ligand had little capacity for the adsorption of uranium. The adsorption equilibrium was correlated by a Langmuir-type equation. The content of neighboring amide oxime groups was 0.406 x 10 -3 mol per kg of base polymer, which corresponded to 0.39 % of the total amount of amide oxime groups. The apparent stoichiometric stability constant for the complex of uranyl ion with the neighboring amide oxime groups in seawater was calculated to be 10 -21.7 . (author)

  20. Lung scintigraphy with Tc-99m-MIBI in diagnosis of active tuberculosis

    International Nuclear Information System (INIS)

    Raziei, G.; Fotouhi, F.; Masjedi, M.R.; Neshandar, E.

    2002-01-01

    Tuberculosis is highly contagious infection and one of the most important health problems in the world today, particularly in our country. Routine diagnostic procedures are sometimes unable to differentiated active from inactive cases particularly in elderly. Children, immunomedics patients, Chronic cases with recurrent actuate infection and in the patients unable to provide sputum for microbiological studies. Several radiopharmaceuticals have been used in the evaluation of active pulmonary TB. In this study Tc 99 m-MIBI lung scan was performed using a single head ADAC gamma camera. 62 patients including 34 APTB 915 male and 19 female) and 28 IPTB 99 male and 19 female) underwent six minutes anterior and posterior chest images 20 and minutes after injection of 10 mCi (370 MBq) of Tc 99 m-MIBI. Visual grading was generated by comparing uptake of lesion with neck soft tissue (sternoleidomastoid muscle) and myocardium. For semiquantitative analysis, regions of interest were draw over the lesion (L), non lesion (NL) and neck soft tissue (SCM) and mean count value of ROIs as well as L/NL, L/SCM values were obtained. Results: From 34 patients with APTB, 4 PTS had normal lung uptake (11.7%), 14 PTs+(41, 2%), 14 PTs++41.2%) and 2 PTS +++ (5.9%), therefore 30 PTs of APTB were positive in scintigraphy (88.2%). From 28 patients with IPTB 21 PTs had normal lung uptake (75%), 6 PTs+ (21.4%) and one PT ++ (3.5%). In the semi quantitative study L/NL ratio is calculated for + about 1.35 +/-0.15 and below from this range is considered with normal limit. The sensitivity, specificity, accuracy, PPV and NPV were 88.2% 75%, 82.2%, 81.1% and 84% respectively. From 100 CXR lesion in APTB, 60 had compatible positive scan and from 86 CXR lesions in IPTB 9 had compatible positive scan, where as incompatible positive findings were 12 and 2 respectively. This study indicates Tc 99 m - MIBI lung scan can be used as a reliable complementary study in diagnosis of APTB and differentiating from

  1. Development of new Czech autoinjector with oxime HI-6 DMS

    International Nuclear Information System (INIS)

    Kuca, K; Jun, D.; Kassa, J.; Marek, J.; Stodulka, P.; Musilek, K.; Dolezal, D.; Povraznik, J.

    2009-01-01

    Oxime HI-6 (1-(2-(hydroxyiminomethyl)pyridinium) -3-(4-carbamoylpyridinium)-2-oxapropane) is considered to be currently the most universal oxime for the potential use as antidote against nerve agents (sarin, cyclosarin, VX, etc.). None of other commercially available oximes (pralidoxime, obidoxime, trimedoxime, MMB4) has broader antidotal effect. Due to this, development of the appropriate salt of this oxime together with its application form (eg. autoinjector) was the main aim of our departments and several private Czech companies (VAKOS XT as., Decomkov Praha sro., ChemProtect as.). In our contribution, we would like to summarize all the steps which were already done. We would like to thank to the Ministry of Industry and Trade of the Czech Republic for the Project No. FIIM2/104.(author)

  2. A comparison of the reactivating and therapeutic efficacy of two novel bispyridinium oximes (K727, K733) with the oxime HI-6 and obidoxime in sarin-poisoned rats and mice.

    Science.gov (United States)

    Kassa, Jiri; Sepsova, Vendula; Matouskova, Lenka; Horova, Anna; Musilek, Kamil

    2015-03-01

    The ability of two novel bispyridinium oximes K727 and K733 and currently available oximes (HI-6, obidoxime) to reactivate sarin-inhibited acetylcholinesterase and to reduce acute toxicity of sarin was evaluated. To investigate the reactivating efficacy of the oximes, the rats were administered intramuscularly with atropine and oximes in equitoxic doses corresponding to 5% of their LD50 values at 1 min after the intramuscular administration of sarin at a dose of 24 µg/kg (LD50). The activity of acetylcholinesterase was measured at 60 min after sarin poisoning. The LD50 value of sarin in non-treated and treated mice was assessed using probit-logarithmical analysis of death occurring within 24 h after intramuscular administration of sarin at five different doses. In vivo determined percentage of reactivation of sarin-inhibited rat blood, diaphragm and brain acetylcholinesterase showed that the potency of both novel oximes K727 and K733 to reactivate sarin-inhibited acetylcholinesterase roughly corresponds to the reactivating efficacy of obidoxime. On the other hand, the oxime HI-6 was found to be the most efficient reactivator of sarin-inhibited acetylcholinesterase. While the oxime HI-6 was able to reduce the acute toxicity of sarin >3 times, both novel oximes and obidoxime decreased the acute toxicity of sarin HI-6 and, therefore, they are not suitable for the replacement of the oxime HI-6 for the antidotal treatment of acute sarin poisoning.

  3. Usefulness of {sup 99m}Tc-depreotide scintigraphy for the diagnosis of bone metastases in non-small cell lung cancer stage 3-4; Apport de la scintigraphie au {sup 99m}Tc-depreotide pour le diagnostic de lesions osseuses secondaires dans le cancer bronchopulmonaire non a petites cellules stade 3-4

    Energy Technology Data Exchange (ETDEWEB)

    Costo, S.; Dunet, V.; Agostini, D.; Bouvard, G. [CHU Cote de Nacre, Service de Medecine Nucleaire et Isotopes, 14 - Caen (France); Halley, A. [Centre Havrais d' Imagerie Nucleaire, 76 - Montivilliers (France); Bergot, E.; Porret, E.; Zalcman, G. [CHU Cote de Nacre, Service de Pneumologie, 14 - Caen (France)

    2009-02-15

    Objective In non-small cell lung cancer (NSCLC), metastatic bone involvement is usually assessed using conventional {sup 99m}Tc-HMDP bone scintigraphy, which has a high sensitivity but a poor specificity. The purpose of this study was to assess the usefulness of the {sup 99m}Tc-D scintigraphy for the detection of malignant bone metastases in patients with NSCLC stage III or IV and to compare these results with {sup 99m}Tc-HMDP bone scan findings. Methods Nineteen patients (13 M and 6 F, mean age 59 years) with proven NSCLC, suspected to have stage III or IV were enrolled prospectively. All patients underwent whole body {sup 99m}Tc-HMDP and {sup 99m}Tc-D scintigraphy to detect bone metastases within a mean interval of 14 days. Each focal uptake of {sup 99m}Tc-D or {sup 99m}Tc-HMDP was considered benign or malignant, leading to positive or negative diagnosis for bone involvement. The final diagnosis of bone metastases was established by a lung specialist, on the basis of additional imaging modalities and of 12 months follow-up. Results Twelve bone lesions were identified by {sup 99m}Tc-D scintigraphy, 10 were classified as bone metastases and two were classified as inflammatory bone lesions. Four patients were metastatic. Fifty eight bone lesions were detected by {sup 99m}Tc-HMDP scintigraphy, 26 of whom were considered malignant, eight patients were thus considered metastatic. Thereby, the two nuclear medicine modalities were concordant for 13 patients, that is 68% of cases and were discordant for six patients, representing 32% of cases. Diagnostic sensitivity, specificity and accuracy of depreotide scintigraphy and {sup 99m}Tc-HMDP bone scintigraphy were 75% for both, 93.3 and 73.3%, and 89.5 and 73.3% respectively. Conclusion Our data suggest that depreotide scintigraphy with the same sensitivity, a better accuracy and specificity than those of {sup 99m}Tc-HMDP bone scan can detect metastatic bone lesions in patients with NSCLC suspected to have stage III or IV

  4. Technetium-99m diethylenetriaminepentaacetic acid radioaerosol scintigraphy in organophosphate induced pulmonary toxicity: experimental study.

    Science.gov (United States)

    Yavuz, Yucel; Kaya, Eser; Yurumez, Yusuf; Sahin, Onder; Bas, Orhan; Fidan, Huseyin; Sezer, Murat

    2008-09-01

    The aim of this experimental study was to investigate pathological signs of lung damages caused by acute organophosphate (OP) poisoning by using Tc-99m DTPA radioaerosol scintigraphy and histopathological investigation. Fourteen rabbits were divided into two equal groups (n = 7). Group 1 (control group) received normal saline (same volume of fenthion, 2 ml/kg) via orogastric tube. Group 2 (OP toxicity group) received 150 mg/kg of fenthion (diluted fenthion, 2 ml/kg) via orogastric tube. Six hours later, Tc-99m-DTPA aerosol inhalation lung scintigraphy was performed in both groups. Then all rabbits were anesthetized with ketamine hydrochloride (35 mg/kg, i.p.) and xysilazine (5 mg/kg, i.p.), and sacrificed by intracardiac blood discharge. The lungs were then removed. There was a significant difference in T1/2 values of Tc-99m DTPA clearance between control group and OP toxicity group (p = 0.04). Intraparenchymal vascular congestion and thrombosis, intraparenchymal hemorrhage, respiratory epithelial proliferation, number of macrophages in the alveolar, and bronchial lumen, alveolar destruction, emphysematous changes, and bronchoalveolar hemorrhage scores were significantly higher in the rabbits exposed to OP compared with the control group (p < 0.05). This study showed that OP toxicity caused a decrease in the alveolar clearance. Tc-99m DTPA radioaerosol inhalation lung scintigraphy was found to be a sensitive determination of acute lung damage in OP poisoning.

  5. Early detection of interstitial pneumonia by 67Ga-citrate scintigraphy

    International Nuclear Information System (INIS)

    Ito, Shinsaku; Mikami, Riichiro; Ryujin, Yoshitada

    1985-01-01

    In this paper we report our recent experience indicating usefulness of 67 Ga-citrate scintigraphy in 4 cases with inflammatory pulmonary diseases. These cases showed abnormal pulmonary 67 Ga uptake with normal chest radiographs. The first case with malignant lymphoma and the second one with lung cancer suffered from pulmonary infection following secondary immuno-insufficiency due to radiotherapy and chemotherapy. Pneumocystis carinii was suspected as causative agent in the first case, and gram negative bacilli in the second case. The third case with lung cancer developed radiation pneumonia after radiotherapy. The fourth case with acute bronchitis developed drug induced interstitial pneumonia presumably due to minocycline administration. It is concluded that 67 Ga-citrate scintigraphy is more sensitive for early detection of interstitial pneumonia than routine chest radiography. (author)

  6. Study of pathophysiology of pulmonary circulation in polycythemia using scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Tadashi; Kawashima, Akira; Kubo, Keiji; Kobayashi, Toshio; Handa, Kenjiro; Yoshimura, Kazuhiko (Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine)

    1993-09-01

    In order to evaluate the pathophysiology of pulmonary circulation in polycythemia, Tl-201 myocardial scintigraphy and perfusion lung scintigraphy with 99m-Tc-MAA were performed in 19 cases of polycythemia including polycythemia rubra vera and in 11 cases of secondary polycythemia due to pulmonary diseases. Tl-201 lung uptake, right ventricular visualization and pulmonary perfusion impairment were studied. In the 19 cases, Tl-201 lung uptake was observed in all cases and 54.5% of them showed moderate lung uptake. The grade of right ventricular visualization was moderate in one case and slight in 16 cases; right ventricular hypertrophy was shown in 89.5% of all cases by Tl-201 scintigraphy, only one of which showed right ventricular hypertrophy on electrocardiography. Abnormalities of lung perfusion consisted of scattered small areas of hypoperfusion in 36.8%, peripheral hypoperfusion in 78.9% and uneven distribution of pulmonary perfusion in 94.7%. The degree of hypoperfusion was slightly related to decrease in FEV 1.0%, V25 and PaO[sub 2] and increase in circulating blood volume and peripheral red blood cell counts. Abnormalities of pulmonary function consisted of increased RV/TLC in 50.0%, increased CV/VC in 35.7% and decreased V25 in 36.8%. Arterial blood gases showed hypoxemia in 57.1%, the degree of which was slightly related to increase in RV/TLC and CV/VC and decrease in V25. Cases of secondary polycythemia due to pulmonary diseases showed more marked right ventricular visualization, pulmonary perfusion impairment and abnormalities of various kinds of pulmonary function than polycythemia rubra vera cases. It seems to be important to evaluate the pathophysiology of pulmonary circulation in polycythemia rubra vera as well as secondary polycythemia due to cardio-pulmonary diseases, because pulmonary perfusion impairment and moderate right ventricular visualization are observed frequently in polycythemia rubra vera. (author).

  7. Study of pathophysiology of pulmonary circulation in polycythemia using scintigraphy

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Tadashi; Kawashima, Akira; Kubo, Keiji; Kobayashi, Toshio; Handa, Kenjiro; Yoshimura, Kazuhiko

    1993-01-01

    In order to evaluate the pathophysiology of pulmonary circulation in polycythemia, Tl-201 myocardial scintigraphy and perfusion lung scintigraphy with 99m-Tc-MAA were performed in 19 cases of polycythemia including polycythemia rubra vera and in 11 cases of secondary polycythemia due to pulmonary diseases. Tl-201 lung uptake, right ventricular visualization and pulmonary perfusion impairment were studied. In the 19 cases, Tl-201 lung uptake was observed in all cases and 54.5% of them showed moderate lung uptake. The grade of right ventricular visualization was moderate in one case and slight in 16 cases; right ventricular hypertrophy was shown in 89.5% of all cases by Tl-201 scintigraphy, only one of which showed right ventricular hypertrophy on electrocardiography. Abnormalities of lung perfusion consisted of scattered small areas of hypoperfusion in 36.8%, peripheral hypoperfusion in 78.9% and uneven distribution of pulmonary perfusion in 94.7%. The degree of hypoperfusion was slightly related to decrease in FEV 1.0%, V25 and PaO 2 and increase in circulating blood volume and peripheral red blood cell counts. Abnormalities of pulmonary function consisted of increased RV/TLC in 50.0%, increased CV/VC in 35.7% and decreased V25 in 36.8%. Arterial blood gases showed hypoxemia in 57.1%, the degree of which was slightly related to increase in RV/TLC and CV/VC and decrease in V25. Cases of secondary polycythemia due to pulmonary diseases showed more marked right ventricular visualization, pulmonary perfusion impairment and abnormalities of various kinds of pulmonary function than polycythemia rubra vera cases. It seems to be important to evaluate the pathophysiology of pulmonary circulation in polycythemia rubra vera as well as secondary polycythemia due to cardio-pulmonary diseases, because pulmonary perfusion impairment and moderate right ventricular visualization are observed frequently in polycythemia rubra vera. (author)

  8. Binding of reactive organophosphate by oximes via hydrogen bond

    Indian Academy of Sciences (India)

    In this contribution, the ability of simple oximes to bind a well-known nerve agent simulant (dimethylmethylphosphonate, DMMP) via hydrogen bond is reported. UV/Vis measurements indicate the formation of 1:1 complexes. 1H-, 31P-NMR titrations and T-ROESY experiments confirm that oximes bind the organophosphate ...

  9. Fluoren-9-one oxime

    Directory of Open Access Journals (Sweden)

    Bernhard Bugenhagen

    2014-03-01

    Full Text Available In the title molecule, C13H9NO, the fluorene system and the oxime group non-H atoms are essentially coplanar, with a maximum deviation from the fluorene mean plane of 0.079 (2 Å for the oxime O atom. A short intramolecular C—H...O generates an S(6 ring. In the crystal, molecules related by a twofold screw axis are connected by O—H...N hydrogen bonds, forming [100] chains Within these chains, molecules related by a unit translation along [100] show π–π stacking interactions between their fluorene ring systems with an interplanar distance of 3.347 (2 Å. The dihedral angle between the fluorene units of adjacent molecules along the helix is 88.40 (2°. There is a short C—H...π contact between the fluorene groups belonging to neighbouring chains.

  10. [The scintigraphy of somatostatin receptors in the carcinoid tumor].

    Science.gov (United States)

    Banzo, J; Abós, M D; Prats, E; Delgado , M; Razola, P; García, S; Gomollón, F; García, F

    2001-02-01

    This study aimed to evaluate the diagnostic utility of 111In-DTPA-D-Phe1-octreotide scintigraphy in the different situations that can be present when an examination is requested during the clinical course of the carcinoid tumor (CT). We have performed 41 scintigraphies with 111In-octreotide (145-185 MBq) in 35 patients (19 females and 16 males) with clinically suspected or confirmed CT. The patients were classified into five groups: Group A: Indolent symptoms of CT (n=9); B: CT staging located in lung (n=4), stomach (n=2), cecum (n=1), thymus (n=1) and pancreas (n=1); C: Carcinoid syndrome (n=1); D: CT staging after surgery located in pancreas (n=1), ovary (n=1), cecum (n=1), stomach (n=1), appendix (n=1) and ileum (n=1); and E: Post-treatment follow-up (n=13), with CT located in bronchial tree (n=5), small intestine (n=3), appendix (n=2), thymus (n=1), ovary (n=1) and unknown primary tumor (n=1). Three patients of this group had one scintigraphic study before the treatment. Head and neck, thorax and abdomen images were obtained at 4 and 24 h in all of the patients and SPECT images of the abdomen (n=14), thorax (n=10), and brain (n=1) were obtained at 24 h in 25 patients. Group A: In the 3 patients with a positive scintigraphy, the definitive diagnosis was meningioma, Hurtle cell's carcinoma and lung adenocarcinoma. The clinical follow-up in the six other patients, at least during one year, did not show any evidence of CT. Group B: Six of the 9 CT were detected with the scintigraphy. In 2 cases of bronchial CT, the scan showed sarcoidotic regional lymph node involvement and CT hepatic and bone metastases, respectively. Group C: The scintigraphy detected hepatic metastases from an unknown primary tumor. Group D: The scintigraphy was positive in 3 cases (hepatic or/and abdominal metastases) and was normal in the other 3. The scintigraphy was negative in one patient with peritoneal metastases. Group E: The scintigraphy was normal in 7 patients in concordance with the

  11. Tc-99m technegas scintigraphy to evaluate the lung ventilation in patients with oral corticosteroid-dependent bronchial asthma

    International Nuclear Information System (INIS)

    Fujita, Jiro; Okada, Hiroki; Momoi, Atsuko; Yamadori, Ichiro; Takahara, Jiro; Tanabe, Masatada; Takahashi, Kazue; Satoh, Katashi; Ohkawa, Motoomi

    1999-01-01

    Bronchial asthma is a clinical syndrome characterized by the reversibility of airway obstruction. Recently it has been suggested that remodeling of the airway causes irreversible airway obstruction which may be responsible for the patient's symptoms. With this background, the purpose of the present study was to assess patients with corticosteroid-dependent asthma by Tc-99m Technegas scintigraphy (Technegas) in both planar and SPECT images. Twelve patients (7 females and 5 males aged 36-72 years with a median age of 60 years: 4 smokers and 8 non-smokers) with oral corticosteroid-dependent asthma were enrolled in this study. Lung ventilation scanning with Technegas in both planar and SPECT images, high-resolution computed tomography, and pulmonary function tests were performed in all patients. The results of Technegas scanning were graded and correlations with other clinical parameters were evaluated. Significant abnormalities were detected by ventilation scintigraphy with Technegas in patients with corticosteroid-dependent bronchial asthma even during remission. Our data demonstrate that airflow obstruction took place in patients with corticosteroid-dependent asthma even during remission. Technegas scanning appears to be a useful radiopharmaceutical for demonstrating airflow obstruction in patients with bronchial asthma. (author)

  12. Tc-99m technegas scintigraphy to evaluate the lung ventilation in patients with oral corticosteroid-dependent bronchial asthma

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Jiro; Okada, Hiroki; Momoi, Atsuko; Yamadori, Ichiro; Takahara, Jiro; Tanabe, Masatada [Kagawa Medical Univ., Miki (Japan); Takahashi, Kazue; Satoh, Katashi; Ohkawa, Motoomi

    1999-08-01

    Bronchial asthma is a clinical syndrome characterized by the reversibility of airway obstruction. Recently it has been suggested that remodeling of the airway causes irreversible airway obstruction which may be responsible for the patient's symptoms. With this background, the purpose of the present study was to assess patients with corticosteroid-dependent asthma by Tc-99m Technegas scintigraphy (Technegas) in both planar and SPECT images. Twelve patients (7 females and 5 males aged 36-72 years with a median age of 60 years: 4 smokers and 8 non-smokers) with oral corticosteroid-dependent asthma were enrolled in this study. Lung ventilation scanning with Technegas in both planar and SPECT images, high-resolution computed tomography, and pulmonary function tests were performed in all patients. The results of Technegas scanning were graded and correlations with other clinical parameters were evaluated. Significant abnormalities were detected by ventilation scintigraphy with Technegas in patients with corticosteroid-dependent bronchial asthma even during remission. Our data demonstrate that airflow obstruction took place in patients with corticosteroid-dependent asthma even during remission. Technegas scanning appears to be a useful radiopharmaceutical for demonstrating airflow obstruction in patients with bronchial asthma. (author)

  13. Clinical significance of abdominal scintigraphy using {sup 99m}Tc-HMPAO-labelled leucocytes in patients with seronegative spondyloarthropathies

    Energy Technology Data Exchange (ETDEWEB)

    Alonso Farto, J.C.; Almoguera Arias, I.; Ortega Valle, A.; Perez Vazquez, J.M. [Department of Nuclear Medicine, Univ. Complutense, Madrid (Spain); Lopez Longo, F.J.; Gonzalez Fernandez, C.M.; Monteagudo Saez, I.; Bascones, M.; Carreno Perez, L. [Department of Rheumatology, ' ' Hospital Universitario Gregorio Maranon' ' , Universidad Complutense, Madrid (Spain)

    2000-12-01

    Abdominal scintigraphy shows silent gut inflammation in patients with spondyloarthropathies (Sp) without clinical evidence of gut inflammation. Abdominal scintigraphy images are different than those obtained in patients with ulcerative colitis or Crohn's disease and are not related to the anti-inflammatory drugs administered. The aim of this study was to examine the clinical associations of findings on abdominal scintigraphy in patients with Sp. A total of 204 Sp patients (European Spondylarthropathy Study Group 1991 criteria) and 54 non-Sp controls receiving non-steroidal anti-inflammatory drugs were studied. Abdominal scintigraphy images were obtained at 30 and 120 min after injection of technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO)-labelled leucocytes. {sup 99m}Tc-HMPAO-labelled leucocyte scans were positive in 104 Sp patients (50.9%) and in six non-Sp controls (2.9%) (P<0.001; OR=8.32; 95% CI=3.23-22.67). Silent gut inflammation was not associated with any of the following: age of onset, duration of evolution, sex, family history of Sp or psoriasis, articular manifestations, extra-articular manifestations, radiological findings or HLA-B27 positivity. Positive abdominal scintigraphy was associated with active disease (P<0.0001; OR=52.7; 95% CI=19-145.6) and an increase in the C-reactive protein (P<0.005; OR=3.4; 95% CI=1.5-7.4). It is concluded that (a) abdominal scintigraphy using {sup 99m}Tc-HMPAO-labelled leucocytes is of value in detecting the silent gut inflammation in Sp patients, and (b) silent gut inflammation is related to the clinical activity, but is not associated with any particular type of illness or with HLA-B27. (orig.)

  14. Radiation protect during the ventilation scintigraphy of Tc99m DTPA radioaerosol in pediatric application

    International Nuclear Information System (INIS)

    Chen, Yu-Wen; Dai, Zen-Kong; Huang, Ying-Fong; Jong, Shiang-Bing

    2000-01-01

    Lung ventilation-perfusion scintigraphy is of great value for the management of patients with both primary lung disease and heart disease, by proving patho- physiological information of importance for the diagnosis, follow-up and functional evaluation of the patients. Krypton 81m radioactive gas is preferable for pediatric application due to its short half-life. However, the rubidium-krypton 81m generator is not popular in hospital of our country. Tc99m DTPA radioaerosol ventilation scintigraphy has its unique convenient for clinical application. But, the most disadvantage of clinical application of Tc99m DTPA radioaerosol is contamination of environment when the poor-cooperative patient can't breathe by mouth. For this reason, we design the certain procedure to reduce the radioaerosol contamination. During May to Aug., 1999, we collect 36 pediatric patients (male to female ratio 2:1, age from 6 months to 20 years old) with clinical history of lung or heart disease, including congenital heart disease, asthma and so on. Before the cases receive 10 to 15 mCi Tc99m DTPA radioaerosol ventilation scan, all of them were trained with breath training. And during the ventilation scintigraphy, the special mouth mask is designed to prevent the radioaerosol leakage into atmosphere. Then Geiger-Muller survey meter was arranged to detect the environmental contamination of radioaerosol in the mask, one and two metes away from the mask every 10 minutes during ventilation scintigraphy procedure and 1 hour after finishing image. Two nuclear medicine physicians evaluated imaging quality of ventilation scintigraphy. Results: Among thirty-six pediatric patients with prior breath training, thirty-two cases are successful to proceed the Tc99m DTPA ventilation scintigraphy. The other four cases that were under three-year-old fail to receive ventilation scintigraphy. There is limited detectable radioactivity in the mouth mask at early 10 minute by Geiger-Muller counter. No significant

  15. The possibility of evaluation on inflammatory change at respiratory tract in chronic bronchial asthma using 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Fukumitsu, Nobuyoshi; Uchiyama, Mayuki; Mori, Yutaka; Kawakami, Kenji; Kikuchi, Ichiro; Shimada, Takao.

    1997-01-01

    67 Ga scintigraphy was performed in 17 patients with chronic bronchial asthma to grasp the inflammatory change of respiratory tract. On 67 Ga scintigraphy, abnormal accumulations were detected on lung fields in 6 cases (35.3%) of 17 cases. In 5 cases of these 6 cases, the defect areas which were pointed out on 81m Kr ventilation scintigraphy were matched to the abnormal accumulation areas which were pointed out on 67 Ga scintigraphy. In dynamics, the abnormal accumulation areas which were pointed out on 67 Ga scintigraphy were matched to the defect areas which had been at all times pointed out on 81m Kr ventilation scintigraphy. 67 Ga scintigraphy was expected to be one of index to grasp the inflammatory change of respiratory tract in patients with chronic bronchial asthma. (author)

  16. A comprehensive evaluation of novel oximes in creation of butyrylcholinesterase-based nerve agent bioscavengers

    Energy Technology Data Exchange (ETDEWEB)

    Katalinić, Maja; Maček Hrvat, Nikolina [Institute for Medical Research and Occupational Health, POB 291, HR-10001 Zagreb (Croatia); Baumann, Krešimir; Morasi Piperčić, Sara; Makarić, Sandro; Tomić, Srđanka; Jović, Ozren; Hrenar, Tomica [Department of Chemistry, Faculty of Science, University of Zagreb, HR-10001 Zagreb (Croatia); Miličević, Ante [Institute for Medical Research and Occupational Health, POB 291, HR-10001 Zagreb (Croatia); Jelić, Dubravko [Fidelta Ltd., HR-10001 Zagreb (Croatia); Žunec, Suzana [Institute for Medical Research and Occupational Health, POB 291, HR-10001 Zagreb (Croatia); Primožič, Ines, E-mail: ines.primozic@chem.pmf.hr [Department of Chemistry, Faculty of Science, University of Zagreb, HR-10001 Zagreb (Croatia); Kovarik, Zrinka, E-mail: zkovarik@imi.hr [Institute for Medical Research and Occupational Health, POB 291, HR-10001 Zagreb (Croatia)

    2016-11-01

    A well-considered treatment of acute nerve agents poisoning involves the exogenous administration of butyrylcholinesterase (BChE, EC 3.1.1.8) as a stoichiometric bioscavenger efficient in preventing cholinergic crises caused by acetylcholinesterase (AChE, EC 3.1.1.7) inhibition. An additional improvement in medical countermeasures would be to use oximes that could reactivate BChE as well to upgrade bioscavenging from stoichiometric to oxime-assisted catalytic. Therefore, in this paper we investigated the potency of 39 imidazolium and benzimidazolium oximes (36 compounds synthesized for the first time) to be considered as the reactivators specifically designed for reactivation of phosphylated human BChE. Their efficiency in the reactivation of paraoxon-, VX-, and tabun-inhibited human BChE, as well as human AChE was tested and compared with the efficiencies of HI-6 and obidoxime, used in medical practice today. A comprehensive analysis was performed for the most promising oximes defining kinetic parameters of reactivation as well as interactions with uninhibited BChE. Furthermore, experimental data were compared with computational studies (docking, QSAR analysis) as a starting point in future oxime structure refinement. Considering the strict criteria set for in vivo applications, we determined the cytotoxicity of lead oximes on two cell lines. Among the tested oxime library, one imidazolium compound was selected for preliminary in vivo antidotal study in mice. The obtained protection in VX poisoning outlines its potential in development oxime-assisted OP-bioscavenging with BChE. - Highlights: • 36 new imidazolium and benzimidazolium oximes were designed and synthesized. • In vitro reactivation kinetics of phosphylated butyrylcholinesterase was studded. • The modes of actions were elucidated by QSAR and docking simulations. • Protection in VX poisoning was 6.3 × LD{sub 50} in in vivo antidotal study in mice. • Imidazolium oxime-assisted catalysis is

  17. A comprehensive evaluation of novel oximes in creation of butyrylcholinesterase-based nerve agent bioscavengers

    International Nuclear Information System (INIS)

    Katalinić, Maja; Maček Hrvat, Nikolina; Baumann, Krešimir; Morasi Piperčić, Sara; Makarić, Sandro; Tomić, Srđanka; Jović, Ozren; Hrenar, Tomica; Miličević, Ante; Jelić, Dubravko; Žunec, Suzana; Primožič, Ines; Kovarik, Zrinka

    2016-01-01

    A well-considered treatment of acute nerve agents poisoning involves the exogenous administration of butyrylcholinesterase (BChE, EC 3.1.1.8) as a stoichiometric bioscavenger efficient in preventing cholinergic crises caused by acetylcholinesterase (AChE, EC 3.1.1.7) inhibition. An additional improvement in medical countermeasures would be to use oximes that could reactivate BChE as well to upgrade bioscavenging from stoichiometric to oxime-assisted catalytic. Therefore, in this paper we investigated the potency of 39 imidazolium and benzimidazolium oximes (36 compounds synthesized for the first time) to be considered as the reactivators specifically designed for reactivation of phosphylated human BChE. Their efficiency in the reactivation of paraoxon-, VX-, and tabun-inhibited human BChE, as well as human AChE was tested and compared with the efficiencies of HI-6 and obidoxime, used in medical practice today. A comprehensive analysis was performed for the most promising oximes defining kinetic parameters of reactivation as well as interactions with uninhibited BChE. Furthermore, experimental data were compared with computational studies (docking, QSAR analysis) as a starting point in future oxime structure refinement. Considering the strict criteria set for in vivo applications, we determined the cytotoxicity of lead oximes on two cell lines. Among the tested oxime library, one imidazolium compound was selected for preliminary in vivo antidotal study in mice. The obtained protection in VX poisoning outlines its potential in development oxime-assisted OP-bioscavenging with BChE. - Highlights: • 36 new imidazolium and benzimidazolium oximes were designed and synthesized. • In vitro reactivation kinetics of phosphylated butyrylcholinesterase was studded. • The modes of actions were elucidated by QSAR and docking simulations. • Protection in VX poisoning was 6.3 × LD 50 in in vivo antidotal study in mice. • Imidazolium oxime-assisted catalysis is feasible

  18. Studies on the polymerization of acrolein oxime, 6

    International Nuclear Information System (INIS)

    Masuda, Seizo; Tamai, Harumi; Ota, Tadatoshi; Torii, Munetomo; Tanaka, Masami.

    1979-01-01

    Radiation-induced polymerization and copolymerization of acrolein oxime are investigated in different solvents and at a wide range of temperature for obtaining information on the reaction mechanism. Acrolein oxime is polymerized ionically, irrespective of dryness of the sample. Arrhenius plots for the polymerization rate, which do not yield a linear relation, can be adequately approximated by two straight lines. An anionic mechanism is operative above the room temperature, while a cationic mechanism predominates below -23 0 C. The reaction in the intermediate temperature range proceeds by a competitive mechanism, and the rate of the anionic and cationic polymerizations becomes equal at the temperature near -5 0 C. The reaction rate is proportional to the square root of dose rate at room temperature and -23 0 C. On the basis of these data, it is proposed that the polymerization of acrolein oxime by γ-irradiation proceeds by free-ionic mechanisms. (author)

  19. Non-invasive evaluation for pulmonary circulatory impairment during exercise in patients with chronic lung disease; With thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiroshi [Kobe Univ. (Japan). School of Medicine

    1990-06-01

    Thallium-201 myocardial scintigraphy was performed at rest and during exercise on sixteen patients with chronic lung disease to evaluate the secondary pulmonary hypertension during exercise with non-invasive technique. An inverse significant correlation was found between thallium activity ratio (TAR) of left ventricle plus ventricular septum to right ventricle and both of pulmonary vascular resistance and right to left ventricular work index ratio during exercise. The patients were divided into three groups according to mean pulmonary arterial pressure (P-bar{sub PA}) at rest and during exercise: the first group consisted of six patients with pulmonary hypertension during exercise (P-bar{sub PA}: below 25 mmHg at rest and above 30 mmHg during exercise), the second group consisted of four patients with pulmonary hypertension at rest (P-bar{sub PA} above 25 mmHg at rest), and the third group consisted of six patients without pulmonary hypertension (P-bar{sub PA} below 25 mmHg at rest, below 30 mmHg during exercise). In the first group, TAR during exercise was lowered than at rest in four patients, and in the second group TAR during exercise was lowered than at rest in all, while in the third group TAR during exercise was increased than at rest in five patients. These results suggest that thallium-201 myocardial scintigraphy can reflect pulmonary hemodynamics during exercise in patients with chronic lung disease and it is of great use to predict the patients with pulmonary hypertension during exercise. (author).

  20. Centrally Acting Oximes in Reactivation of Tabun-Phosphoramidated AChE

    Science.gov (United States)

    Kovarik, Zrinka; Maček, Nikolina; Sit, Rakesh K.; Radić, Zoran; Fokin, Valery V.; Sharpless, K. Barry; Taylor, Palmer

    2012-01-01

    Organophosphates (OP) inhibit acetylcholinesterase (AChE, E.C.3.1.1.7), both in peripheral tissues and central nervous system (CNS), causing adverse and sometimes fatal effects due to the accumulation of neurotransmitter acetylcholine (ACh). The currently used therapy, focusing on the reactivation of inhibited AChE, is limited to peripheral tissues because commonly used quaternary pyridinium oxime reactivators do not cross the blood brain barrier (BBB) at therapeutically relevant levels. A directed library of thirty uncharged oximes that contain tertiary amine or imidazole protonable functional groups that should cross the BBB as unionized species was tested as tabun-hAChE conjugate reactivators along with three reference oximes: DAM (diacetylmonoxime), MINA (monoisonitrosoacetone), and 2-PAM. The oxime RS150D [N-((1-(3-(2-((hydroxyimino)methyl)-1H-imidazol-1-yl)propyl)-1H-1,2,3-triazol-4-yl)methyl)benzamide] was highlighted as the most promising reactivator of the tabun-hAChE conjugate. We also observed that oximes RS194B [N-(2-(azepan-1-yl)ethyl)-2-(hydroxyimino)acetamide] and RS41A [2-(hydroxyimino)-N-(2-(pyrrolidin-1-yl)ethyl)acetamide], which emerged as lead uncharged reactivators of phosphylated hAChE with other OPs (sarin, cyclosarin and VX), exhibited only moderate reactivation potency for tabun inhibited hAChE. This implies that geometry of oxime access to the phosphorus atom conjugated to the active serine is an important criterion for efficient reactivation, along with the chemical nature of the conjugated moiety: phosphorate, phosphonate, or phosphoramidate. Moreover, modification of the active center through mutagenesis enhances the rates of reactivation. The phosphoramidated-hAChE choline-binding site mutant Y337A showed three-times enhanced reactivation capacity with non-triazole imidazole containing aldoximes (RS113B, RS113A and RS115A) and acetamide derivative (RS194B) than with 2PAM. PMID:22960624

  1. Estimation of pulmonary hypertension by perfusion lung scintigraphy: Gravitational effect of postural changes between the lateral decubitus positions

    International Nuclear Information System (INIS)

    Tanaka, Masao; Fujii, Tadashige; Hirayama, Jiro; Okubo, Shinichi; Sekiguchi, Morie

    1990-01-01

    To estimate pulmonary hypertension in patients with various heart diseases, we devised a new method using perfusion lung scintigraphy with 99m Tc-labelled macroaggregated albumin. In this method, changes in the distribution of pulmonary perfusion caused by gravitational effects, namely, changes in the total count ratios of the right lung against the left lung between right and left lateral decubitus positions (rt/lt), were assessed in 62 patients and in 10 normal subjects. The rt/lt ratios were calculated as indices of the above changes. They correlated significantly with mean pulmonary arterial pressure (mPAP) (γ=-0.62, P<0.001), pulmonary capillary wedge pressure (γ=-0.63, P<0.001) and pulmonary arteriolar resistance (γ=0.50, P<0.001) in all subjects. In 17 patients with valvular heart diseases, the ratio correlated significantly with mPAP (γ=-0.84, P<0.001). In 10 patients with various heart diseases, the U/S ratio, i.e. the index of changes in the count ratios of the upper field against the lower field for the right lung following postural change from the uprigth to the supine position, was also obtained as well as the rt/lt ratio. The latter evidenced a better correlation with mPAP (γ=-0.90, P<0.001) than the former (γ=-0.64, P<0.05). We conclude that this method is valuable as a noninvasive approach for the estimation of pulmonary hypertension. (orig.)

  2. Evaluation of oxime efficacy in nerve agent poisoning: Development of a kinetic-based dynamic model

    International Nuclear Information System (INIS)

    Worek, Franz; Szinicz, Ladislaus; Eyer, Peter; Thiermann, Horst

    2005-01-01

    The widespread use of organophosphorus compounds (OP) as pesticides and the repeated misuse of highly toxic OP as chemical warfare agents (nerve agents) emphasize the necessity for the development of effective medical countermeasures. Standard treatment with atropine and the established acetylcholinesterase (AChE) reactivators, obidoxime and pralidoxime, is considered to be ineffective with certain nerve agents due to low oxime effectiveness. From obvious ethical reasons only animal experiments can be used to evaluate new oximes as nerve agent antidotes. However, the extrapolation of data from animal to humans is hampered by marked species differences. Since reactivation of OP-inhibited AChE is considered to be the main mechanism of action of oximes, human erythrocyte AChE can be exploited to test the efficacy of new oximes. By combining enzyme kinetics (inhibition, reactivation, aging) with OP toxicokinetics and oxime pharmacokinetics a dynamic in vitro model was developed which allows the calculation of AChE activities at different scenarios. This model was validated with data from pesticide-poisoned patients and simulations were performed for intravenous and percutaneous nerve agent exposure and intramuscular oxime treatment using published data. The model presented may serve as a tool for defining effective oxime concentrations and for optimizing oxime treatment. In addition, this model can be useful for the development of meaningful therapeutic animal models

  3. Successful application of technetium-99m-labeled octreotide acetate scintigraphy in the detection of ectopic adrenocorticotropin-producing bronchial carcinoid lung tumor: a case report

    Directory of Open Access Journals (Sweden)

    Fallahi Babak

    2010-10-01

    Full Text Available Abstract Introduction The diagnostic efficacy of somatostatin receptor scintigraphy labeling with 111 indium in the localization of tumors has been assessed in a limited number of patients with contradictory outcomes. Here, we describe the case of a patient with an ectopic adrenocorticotropic hormone-producing bronchial carcinoid tumor diagnosed preoperatively using technetium-99m-labeled octreotide acetate scintigraphy. Case presentation A 29-year-old Asian man presented to our hospital with the typical clinical features of Cushing's syndrome, which he had had for a duration of 18 months. The results of a biochemical evaluation revealed he had adrenocorticotropic hormone-dependent Cushing's syndrome. The results of a spiral abdominal computed tomography scan showed he had bilateral adrenal hypertrophy. A magnetic resonance image of the patient's brain showed he had a normal hypophysis. Whole body technetium-99m-labeled octreotide acetate scintigraphy was performed to check for the presence of an ectopic adrenocorticotropic hormone-producing tumor. The scan results showed a small focal increase in uptake in the lower lobe of our patient's right lung, just above his diaphragm. A spiral chest computed tomography scan also revealed a small non-specific lesion in the same region. A transthoracic biopsy was then performed. Pathological evaluation confirmed the diagnosis of a carcinoid tumor, of the adrenocorticotropic hormone-producing type. After surgical removal, the patient's symptoms resolved and significant clinical improvement was achieved. Conclusions This case report shows that technetium-99m-labeled octreotide acetate scintigraphy can effectively detect an ectopic adrenocorticotropic hormone-producing bronchial carcinoid.

  4. Dose response toxic effects of different oximes in vivo: pathohystological evaluation

    International Nuclear Information System (INIS)

    Jacevic, V.

    2009-01-01

    The acute toxicity of oximes is crucial for the assessment of a dose applied as a treatment for organophosphorus intoxications. This is why we decided to investigate which morphological lesions could be produced in Wistar rats after treatment with increasing doses of HI-6, Obidoxime, K027, K048, and K075. In the first part of this study, tested oximes were preliminarily tested in order to obtain their LD50 values. Survival rates were monitored 24 hours after application of each oxime. In separate experiment animals were sacrificed 7 days after single im application of 0.1 LD50 and 0.5 LD50 of each oxime, and hearts, diaphragms and musculus popliteus were obtained for pathohistological analysis. Tissue damage score (TDS) was based on an estimation scale from 0 (no damage) to 5 (strong damage, massive necrotic fields). In rats treated with of 0.1 LD50 of HI-6 and K027 microscopic findings were similar to those evaluated in the control groups, only. More intensive alterations, but still mild and reversible degenerative and vascular changes, were established in tissue samples after treatment with 0.1 LD50 of Obidoxime, K048 and K075, but their values were also similar to the control group. Acute lesions were developed in tissue samples within 7 days following treatment with 0.5 LD50 of all oximes. The most severe tissue alterations were found in rats treated with 0.5 LD50 of K048 and K075 (p < 0.001 vs. control and HI-6). These observations of the earliest tissues events are helping to guide of applications of novel development oximes.(author)

  5. New Cinchona Oximes Evaluated as Reactivators of Acetylcholinesterase and Butyrylcholinesterase Inhibited by Organophosphorus Compounds

    Directory of Open Access Journals (Sweden)

    Maja Katalinić

    2017-07-01

    Full Text Available For the last six decades, researchers have been focused on finding efficient reactivators of organophosphorus compound (OP-inhibited acetylcholinesterase (AChE and butyrylcholinesterase (BChE. In this study, we have focused our research on a new oxime scaffold based on the Cinchona structure since it was proven to fit the cholinesterases active site and reversibly inhibit their activity. Three Cinchona oximes (C1, C2, and C3, derivatives of the 9-oxocinchonidine, were synthesized and investigated in reactivation of various OP-inhibited AChE and BChE. As the results showed, the tested oximes were more efficient in the reactivation of BChE and they reactivated enzyme activity to up to 70% with reactivation rates similar to known pyridinium oximes used as antidotes in medical practice today. Furthermore, the oximes showed selectivity towards binding to the BChE active site and the determined enzyme-oxime dissociation constants supported work on the future development of inhibitors in other targeted studies (e.g., in treatment of neurodegenerative disease. Also, we monitored the cytotoxic effect of Cinchona oximes on two cell lines Hep G2 and SH-SY5Y to determine the possible limits for in vivo application. The cytotoxicity results support future studies of these compounds as long as their biological activity is targeted in the lower micromolar range.

  6. Reproducibility of Lobar Perfusion and Ventilation Quantification Using SPECT/CT Segmentation Software in Lung Cancer Patients.

    Science.gov (United States)

    Provost, Karine; Leblond, Antoine; Gauthier-Lemire, Annie; Filion, Édith; Bahig, Houda; Lord, Martin

    2017-09-01

    Planar perfusion scintigraphy with 99m Tc-labeled macroaggregated albumin is often used for pretherapy quantification of regional lung perfusion in lung cancer patients, particularly those with poor respiratory function. However, subdividing lung parenchyma into rectangular regions of interest, as done on planar images, is a poor reflection of true lobar anatomy. New tridimensional methods using SPECT and SPECT/CT have been introduced, including semiautomatic lung segmentation software. The present study evaluated inter- and intraobserver agreement on quantification using SPECT/CT software and compared the results for regional lung contribution obtained with SPECT/CT and planar scintigraphy. Methods: Thirty lung cancer patients underwent ventilation-perfusion scintigraphy with 99m Tc-macroaggregated albumin and 99m Tc-Technegas. The regional lung contribution to perfusion and ventilation was measured on both planar scintigraphy and SPECT/CT using semiautomatic lung segmentation software by 2 observers. Interobserver and intraobserver agreement for the SPECT/CT software was assessed using the intraclass correlation coefficient, Bland-Altman plots, and absolute differences in measurements. Measurements from planar and tridimensional methods were compared using the paired-sample t test and mean absolute differences. Results: Intraclass correlation coefficients were in the excellent range (above 0.9) for both interobserver and intraobserver agreement using the SPECT/CT software. Bland-Altman analyses showed very narrow limits of agreement. Absolute differences were below 2.0% in 96% of both interobserver and intraobserver measurements. There was a statistically significant difference between planar and SPECT/CT methods ( P software is highly reproducible. This tridimensional method yields statistically significant differences in measurements for right lung lobes when compared with planar scintigraphy. We recommend that SPECT/CT-based quantification be used for all lung

  7. Recent advances in evaluation of oxime efficacy in nerve agent poisoning by in vitro analysis

    International Nuclear Information System (INIS)

    Worek, F.; Eyer, P.; Aurbek, N.; Szinicz, L.; Thiermann, H.

    2007-01-01

    The availability of highly toxic organophosphorus (OP) warfare agents (nerve agents) underlines the necessity for an effective medical treatment. Acute OP toxicity is primarily caused by inhibition of acetylcholinesterase (AChE). Reactivators (oximes) of inhibited AChE are a mainstay of treatment, however, the commercially available compounds, obidoxime and pralidoxime, are considered to be rather ineffective against various nerve agents, e.g. soman and cyclosarin. This led to the synthesis and investigation of numerous oximes in the past decades. Reactivation of OP-inhibited AChE is considered to be the most important reaction of oximes. Clinical data from studies with pesticide-poisoned patients support the assumption that the various reactions between AChE, OP and oxime, i.e. inhibition, reactivation and aging, can be investigated in vitro with human AChE. In contrast to animal experiments such in vitro studies with human tissue enable the evaluation of oxime efficacy without being affected by species differences. In the past few years numerous in vitro studies were performed by different groups with a large number of oximes and methods were developed for extrapolating in vitro data to different scenarios of human nerve agent poisoning. The present status in the evaluation of new oximes as antidotes against nerve agent poisoning will be discussed

  8. Role of cineoesophageal scintigraphy in primary and secondary oesophageal motility disorders. About a 12000 radionuclide transit study experience

    International Nuclear Information System (INIS)

    Guillet, J.; Role, C.; Imbert, Y.

    1996-01-01

    Cineoesophageal scintigraphy (COS) and evaluation of oesophageal motility disorders. A 12 000 COS experience with 99m TC-sulfur colloid radiolabeled liquids is detailed. Functional qualitative and quantitative isotopic imaging parameters describe the propulsion abnormalities: mainly achalasia, diffuse esophageal spasm, nutcracker esophagus, non-specific motor disorders, systemic sclerosis, diabetes. Respective advantages and drawbacks of manometry and scintigraphy are discussed. Manometry only can measure pressures, scintigraphy only can measure bolus propulsion by peristaltic waves. Physiological and comfortable conditions, sensitivity, quantitative functional imaging, evidence of lung aspiration when swallowing advantage. (authors). 117 refs., 14 figs., 3 tabs

  9. Oxime Ethers of (E)-11-Isonitrosostrychnine as Highly Potent Glycine Receptor Antagonists

    DEFF Research Database (Denmark)

    Mohsen, Amal M Y; Mandour, Yasmine M; Sarukhanyan, Edita

    2016-01-01

    of the crystal structure of the α3 glycine receptor indicated the same orientation of the strychnine core for all analogues. For the most potent oxime ethers, the ether substituent was accommodated in a lipophilic receptor binding pocket. The findings identify the oxime hydroxy group as a suitable attachment...

  10. Comparison of oxime reactivation and aging of nerve agent-inhibited monkey and human acetylcholinesterases.

    Science.gov (United States)

    Luo, Chunyuan; Tong, Min; Maxwell, Donald M; Saxena, Ashima

    2008-09-25

    Non-human primates are valuable animal models that are used for the evaluation of nerve agent toxicity as well as antidotes and results from animal experiments are extrapolated to humans. It has been demonstrated that the efficacy of an oxime primarily depends on its ability to reactivate nerve agent-inhibited acetylcholinesterase (AChE). If the in vitro oxime reactivation of nerve agent-inhibited animal AChE is similar to that of human AChE, it is likely that the results of an in vivo animal study will reliably extrapolate to humans. Therefore, the goal of this study was to compare the aging and reactivation of human and different monkey (Rhesus, Cynomolgus, and African Green) AChEs inhibited by GF, GD, and VR. The oximes examined include the traditional oxime 2-PAM, two H-oximes HI-6 and HLo-7, and the new candidate oxime MMB4. Results indicate that oxime reactivation of all three monkey AChEs was very similar to human AChE. The maximum difference in the second-order reactivation rate constant between human and three monkey AChEs or between AChEs from different monkey species was 5-fold. Aging rate constants of GF-, GD-, and VR-inhibited monkey AChEs were very similar to human AChE except for GF-inhibited monkey AChEs, which aged 2-3 times faster than the human enzyme. The results of this study suggest that all three monkey species are suitable animal models for nerve agent antidote evaluation since monkey AChEs possess similar biochemical/pharmacological properties to human AChE.

  11. The usefulness of 99mTc-Technegas scintigraphy for diagnosing pulmonary impairment caused by pulmonary emphysema

    International Nuclear Information System (INIS)

    Satoh, Katashi; Takahashi, Kazue; Kobayashi, Takuya; Yamamoto, Yuka; Nishiyama, Yoshihiro; Tanabe, Masatada

    1998-01-01

    X-ray computed tomography (CT) has been used for diagnosis of pulmonary emphysema because it can reveal the morphology of low attenuation areas. Recently, 99m Tc-Technegas imaging, one of several types of scintigraphic techniques, has been used for ventilation scintigraphy. Technegas scintigraphy was performed on 15 patients with pulmonary emphysema, and we compared the extent and degree of abnormal findings on Technegas scintigraphy with the extent of low attenuation areas shown by CT. We classified the findings of Technegas imaging into three grades, from mild to severe, according to the extent of peripheral irregularity and central hot spot formation. We also classified the findings of CT as centrilobular emphysema into three grades from mild to severe according to the extent of low attention areas in the peripheral lung fields. In 5 cases, CT and Technegas assessment resulted in equivalent diagnoses. In eight cases, Technegas images showed more detailed findings than CT images. In the two remaining cases, which were diagnosed as panlobular emphysema on CT, Technegas images showed the severe stage. Technegas scintigraphy was useful for diagnostic assessment of pulmonary emphysema, especially for panlobular emphysema, which is difficult to distinguish from the normal lung condition by CT assessment. (author)

  12. Radiospirometry and perfusion scintigraphy in cases of limited pulmonary fibrosis

    International Nuclear Information System (INIS)

    Tarkowska, A.; Smajkiewicz, L.; Szarewicz-Adamczyk, W.; Zaorska-Rajca, J.; Woytowicz, A.; Patyra, S.

    1981-01-01

    In 60 cases of limited pulmonary fibrosis radiospirometric investigation was performed using 133 Xe and a four-channel set. Perfusion scintigraphy was done as well after administration of labelled molecules. In all patients abnormalities were found in the results of both isotope methods suggesting presence of disturbances in the regional pulmonary functions. These disturbances included impairment of perfusion as well as ventilation, with evidence of obturation, increased volume of residual air, and decreased vital and total capasity of the lungs. These abnormalities occurred exclusively or most intensively in the areas corresponding to the location of the anatomical change, and in a considerable proportion of cases they were more extensive than the radiological changes. In about 40% of the patients in the contralateral lung diffuse changes of perfusion and ventilation were present, although much less intense, suggesting concomitant chronic obturative disease. The authors think that perfusion scintigraphy and radiospirometry owing to their value as a method of assessing pulmonary function are useful in cases of pulmonary fibrosis for establishing treatment methods and for evaluating disability to work. (author)

  13. Cold metastases detected by bone scintigraphy in aggressive lung cancer

    International Nuclear Information System (INIS)

    Martinez Carsi, C.; Perales Vila, A.; Ruiz Hernandez, G.; Sanchez Marchori, C.; Oro Camps, J.

    1998-01-01

    A case of a 55-year-old man was remitted to Traumatology Department to present back pain of two weeks of evolution. The results of bone scintigraphy and the patient's evolution allowed the diagnosis. This case report and a literature review showed the importance of using a routine bone scan in diagnosis of bone metastases. (orig.) [de

  14. Bone scintigraphy for metastasis detection in canine osteosarcoma

    International Nuclear Information System (INIS)

    Forrest, L.J.; Thrall, D.E.

    1994-01-01

    The purpose of this study was to assess the usefulness of serial bone scintigraphy in the detection of skeletal and extraskeletal metastases in dogs with appendicular osteosarcoma. Twenty-six dogs with primary, appendicular osteosarcoma were entered into a limb-sparing protocol. Bone scintigraphy was performed upon presentation, after neoadjuvant therapy but prior to surgery and at selective intervals after limb-sparing surgery to evaluate for the presence of metastasis. Thoracic radiographs, and radiographs of other sites, were also made at the time of each bone scan. All dogs had a complete necropsy. No dog had bone or lung metastases detected prior to treatment. The bone scans, medical records, and radiographs of each dog were reviewed retrospectively. All but one dog developed metastatic disease. Bone metastatic sites were confirmed at necropsy in 12 of the 26 dogs. Seven of these 12 dogs had bone metastatic sites which were not producing clinical signs, i.e. an occult metastasis. In five of the seven dogs, the occult site was the first metastatic site detected. Extraskeletal metastases were identified scintigraphically in six of the 26 dogs, but these were clinically apparent prior to bone scintigraphy in each dog. Suspected malignant scintigraphic lesions were proven benign in six dogs. In five dogs with malignant bone lesions at necropsy the last bone scan prior to euthanasia was normal. The time interval between scintigraphy and necropsy was variable in these five dogs. All dogs without bone metastases at necropsy had normal bone scans. This study validates the usefulness of bone scintigraphy for detection of occult bone metastasis and improved ability for tumor staging in dogs with appendicular osteosarcoma

  15. Comparative scintigraphy in oleic acid pulmonary microvascular injury

    International Nuclear Information System (INIS)

    Sugerman, H.J.; Hirsch, J.I.; Tatum, J.L.; Strash, A.M.; Sharp, D.E.; Greenfield, L.J.

    1982-01-01

    Computerized gamma scintigraphy revealed a significant (p less than 0.001) rising lung:heart radioactivity ratio, which has been called ''slope of injury'' or ''slope index'', with both 99mTechnetium-tagged human serum albumin (99mTc-HSA) and 99mTechnetium-tagged red blood cells (99Tc-RBC) after 0.05 or 0.2 ml/kg iv oleic acid administration to dogs. This slope index was significantly greater with 99mTc-HSA than 99mTc-RBC (p less than 0.001). These findings verify that the scintigraphic 99mTc-HSA slope of injury is a result of a pulmonary capillary protein leak and not oleic acid induced changes in pulmonary blood or air volume. The leak of red blood cells noted with scintigraphy was confirmed by light microscopy and examination of the tracheal edema fluid. The leak of albumin, however, was much greater than the leak of red blood cells by microscopy and tracheal fluid examination, confirming the scintigraphic data. This study provides further evidence that computerized gamma scintigraphy will be of value for the diagnosis of permeability pulmonary edema and its response to treatment

  16. Esophageal function scintigraphy as parameter for organ involvement of progressive systemic scleroderma

    International Nuclear Information System (INIS)

    Leisner, B.; Koenig, G.; Hundegger, K.; Luderschmidt, C.

    1986-01-01

    Involvement of internal organs such as lungs, heart and kidneys, is a life-threatening complication in progressive systemic scleroderma (PSS). However, the earliest and the most frequent internal manifestation of PSS is that of esophageal dysfunction. This study was undertaken to determine whether the new, sensitive and noninvasive esphageal function scintigraphy (EFS) enables us to identify patients likely to develop pulmonary interstitial fibrosis. 131 patients with PSS of different clinical types and courses underwent EFS. The esophageal clearance of a sup(99m)Tc-tagged 15 ml water bolus was measured. In normals, 91 +- 4.8% of the maximal rate were cleared from the ROI comprising the whole esophagus 10 sec after T max was reached. For comparison, chest X-rays and pulmonary function data were used. In the presence of interstitial lung disease EFS gave normal results in four patients only (sensitivity, 89%). All cases with either severely impaired lung function or signs of fibrosis on X-ray films showed esophageal clearance values below 40%. Moreover, esophageal motility disorders were seen in 32 among 43 patients with normal lung function. There was a correlationi between the stage and progression (reflected by unspecific signs of inflammation) and the incidence and severity of both lung function impairment and esophageal dysfunction. In conclusion, functional scintigraphy proved to be a very sensitive diagnostic procedure in the screening for internal manifestations of progressive systemic scleroderma. (Author)

  17. Clinical efficacy of 99mTc-tetrofosmin myocardial scintigraphy

    International Nuclear Information System (INIS)

    Adachi, Itaru; Sugioka, Yasushi; Tanaka, Yasunori

    1993-01-01

    99m Tc-tetrofosmin is a lipophilic, cationic diphosphine which has been developed for myocardial imaging. We examined 9 patients with ischemic heart disease including 3 angina pectoris (AP), 4 old myocardial infarction (OMI), 1 AP with OMI and 1 syndrome X. One patient was examined before and after operation. Three hundred seventy MBq of 99m Tc-tetrofosmin was injected during exercise and 740 MBq at rest. And 74 MBq of 201 Tl myocardial exercise and redistribution scintigraphy was also performed to compare with 99m Tc-tetrofosmin myocardial scintigraphy. SPECT, multiple gated SPECT and anterior planar images were obtained in all cases. We calculated percent wall thickening (%WT) using multiple gated SPECT images. There was a decreased lung uptake in 99m Tc-tetrofosmin planar images compared to 201 Tl myocardial scintigraphy. Liver and Biliary system uptake in 99m Tc-tetrofosmin images was decreased with intake of milk. Segmental comparison of SPECT images showed an agreement in 9/10 of the segment between 201 Tl and 99m Tc-tetrofosmin. We could obtain excellent quality of multiple gated SPECT images in all patients. We could calculate percent wall thickening (%WT) in all patients. We conclude that 99m Tc-tetrofosmin myocardial scintigraphy should provide usefulness for detection of ischemic myocardium as same as 201 Tl myocardial scintigraphy, although the biologic characteristics of two agents were different. These data and excellent quality of multiple gated SPECT images suggest that 99m Tc-tetrofosmin is a new 99m Tc agent for evaluation of patients with ischemic heart disease. (author)

  18. Detection of Metastases of Primary Hepatocellular Carcinoma with {sup 99m}Tc-HIDA Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Dae Suk [Seoul National University College of Medicine, Seoul (Korea, Republic of); Hong, Kee Suk; Hong, Seong Woon; Lee, Jhin Oh; Kang, Tae Woong [Cancer Reseach Hospital, Korea Advanced Energy Institute, Seoul (Korea, Republic of)

    1983-03-15

    {sup 99m}Tc-Sulfur Colloid is concentrated in Kupffer cells of the liver, whereas the new biliary agents such as {sup 99m}Tc-HIDA are processed by hepatic parenchymal cells. The distant metastatic lesions in skull and lung of the primary hepatocellular carcinoma in 38-year old Korean male were detected with {sup 99m}Tc-HIDA scintigraphy. The chest PA, skull bone X-ray and radionuclide scintigraphic studies are illustrated. This observation suggests that {sup 99m}Tc-HIDA scintigraphy is useful for detection of distant metastases of primary hepatocellular carcinoma.

  19. Fast and low-temperature sintering of silver complex using oximes as a potential reducing agent for solution-processible, highly conductive electrodes

    International Nuclear Information System (INIS)

    Yoo, Ji Hoon; Park, Su Bin; Kim, Ji Man; Han, Dae Sang; Chae, Jangwoo; Kwak, Jeonghun

    2014-01-01

    Highly conductive, solution-processed silver thin-films were obtained at a low sintering temperature of 100 °C in a short sintering time of 10 min by introducing oximes as a potential reductant for silver complex. The thermal properties and reducibility of three kinds of oximes, acetone oxime, 2-butanone oxime, and one dimethylglyoxime, were investigated as a reducing agent, and we found that the thermal decomposition product of oximes (ketones) accelerated the conversion of silver complex into highly conductive silver at low sintering temperature in a short time. Using the acetone oxime, the silver thin-film exhibited the lowest surface resistance (0.91 Ω sq −1 ) compared to those sing other oximes. The silver thin-film also showed a high reflectance of 97.8%, which is comparable to evaporated silver films. We also demonstrated inkjet printed silver patterns with the oxime-added silver complex inks. (paper)

  20. Pulmonary metastasis in osteosarcoma in bone scintigraphy: 2 case reports poster

    International Nuclear Information System (INIS)

    Grobocopatel, D.; Silva, N.J.; Hunsche, A.; Fernandes, D.D.; Berdichevski, E.H.; Cembrani, L.; Anselmi, C.E.; Anselmi, O.E.

    2004-01-01

    Full text: Osteosarcoma is considered the most common malignant primary bone tumour in children and adolescents. The lungs are the common sites of metastasis, which, if present, are associated with poor prognosis. Imaging workup includes x-ray, computed tomography, nuclear resonance imaging and bone scintigraphy in order to diagnose, help to choose appropriate treatment and prognosticate this disease. Chemotherapy is used to increase survival rate and to control the occurrence of lung metastasis. CASE 1: ELWS, male, 6 years old. The patient had a left knee trauma followed by increase in size and pain over 15 days. Knee x-ray showed a voluminous lesion and densely calcified tissue in the left knee, with soft tissue involvement. Chest x-ray showed multiple nodular dense lesions diffusely involving the lungs. Left knee MRI showed a neoplasm involving the distal epiphysis of the femur with extension from the bone marrow to the trochanteric region. Biopsy diagnosed small cell osteosarcoma. Chest computed tomography showed multiple opacities in the parenchyma of both lungs, most with calcification, predominantly in the cortical region. Bone scintigraphy showed intense uptake of the radiopharmaceutical in the distal half of the left femur and focal areas of increased uptake in the skull, left humerus, right scapula, thoracic soft tissue (mostly in the right side, in the same place as the pulmonary metastasis seen in the chest computed tomography), 12th thoracic vertebra, 4th lumbar vertebra and in the pelvis. CASE 2: ACD, male 20 years old. The patient presented pain and increase in size of the right knee starting 5 months ago. Right knee x-ray: insufflating bony lesion in the proximal epiphysis of the right tibia compatible with osteosarcoma; increase in volume in soft tissue around the knee. Right knee MRI: voluminous expansive osteoblastic lesion hypointense in T1 and heterogeneous in T2, diffusely enhanced by the use of gadolinium-DTPA; the lesion involved almost

  1. Inflammatory/granulomatous diseases of the lung

    International Nuclear Information System (INIS)

    Ivancevic, V.; Munz, D.L.

    1998-01-01

    The term 'inflammatory' and 'granulomatous' lung disease represents a pool of many etiologically different diseases, the pathologic mechanisms of which are characterized by inflammatory reactions of varying intensity and cell composition. In sarcoidosis and other granulomatous diseases as well as in lung fibroses, gallium scintigraphy allows reliable non-invasive estimation of alveolitis activity and is suitable for therapy monitoring. Granulomatous diseases seem to be detectable sensitively by means of somatostatin receptor scintigraphy as well. It is yet uncertain, whether positron emission tomography with F-18 fluordeoxyglucose will play a role in quantitative assessment of disease activity in sarcoidosis. Gallium scintigraphy is very useful in the early detection of pulmonary complications in AIDS patients. Pneumocystis carinii pneumonia, which is important in this patient population, can also be detected by both Tc-99m and In-111 labelled polyclonal human immunoglobulin, and in future possibly with a monoclonal antibody fragment against Pneumocystis carinii as well. The significance of primary bacterial pneumonias has decreased and nuclear medicine procedures for diagnosing inflammation are needed only exceptionally in this indication. (orig.) [de

  2. A Development of Rapid, Practical and Selective Process for Preparation of Z-Oximes

    International Nuclear Information System (INIS)

    Kim, Bo Ram; Sung, Gi Hyeon; Yoon, Yongjin; Kim, Jeumjong

    2013-01-01

    Oximes are important functional groups in organic chemistry due to their synthetic utility as protecting groups for carbonyl groups and their ability to form other functionalities, and their biological activity. Oximes are commonly prepared by condensing aldehydes and ketones with hydroxylamines. These reactions do not always go to completion and reaction times can be long, and therefore there has been interest in more convenient and efficient methods. To avoid the typical disadvantage, conversion of aldehydes and ketones to the corresponding oximes was accomplished by using various catalysts such as organic acid/bases, AcONa, alumina, TiO 2 /SO 4 silica gel, Oxone, NaOH, basic ionic liquid 1-butyl-3-methylimidazolium hydroxide, polyoxometalates, Na 2 SO 4 , and CuSO 4 /K 2 CO 3 under the solvent, the solvent-free or the microwave conditions. These are one and more drowbacks such as long reaction time, use of catalysts, inconvenients due to solid-sate reaction, low yields and limitaion of some carbonyl compounds. On the other hand, H. Sharghi, et al.,14 reported the catalysis of the stereoselectivity of CuSO 4 and K 2 CO 3 in the oximation of aldehydes and ketones under solvent-free conditions. Although this method show high selectivity, it is inconvenient for the large scale experiments and the industrial process due to the solvent-free condition. Therefore, we attempted to develop a more convenient and efficient solution method. According to the literatures, treatment of potassium carbonate with methanol generates slightly the potassium methoxide, which may be useful for forming the free NH 2 OH from its salts. We describe the oximation of aldehyde and ketone using NH 2 OH·HCl/K 2 CO 3 in methanol solvent. We selected oximation of acetophenone (1a) with hydroxylamine hydrochloride as a model and its behavior was investigated in seven solvents involving methanol (Table 1). As shown in the Entry 2 in Table 1, compound 1a was treated with hydroxylamine

  3. A Development of Rapid, Practical and Selective Process for Preparation of Z-Oximes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Ram; Sung, Gi Hyeon; Yoon, Yongjin [Gyeongsang National Univ., Jinju (Korea, Republic of); Kim, Jeumjong [Electronic and Telecommunications Research Institute, Daejeon (Korea, Republic of)

    2013-04-15

    Oximes are important functional groups in organic chemistry due to their synthetic utility as protecting groups for carbonyl groups and their ability to form other functionalities, and their biological activity. Oximes are commonly prepared by condensing aldehydes and ketones with hydroxylamines. These reactions do not always go to completion and reaction times can be long, and therefore there has been interest in more convenient and efficient methods. To avoid the typical disadvantage, conversion of aldehydes and ketones to the corresponding oximes was accomplished by using various catalysts such as organic acid/bases, AcONa, alumina, TiO{sub 2}/SO{sub 4} silica gel, Oxone, NaOH, basic ionic liquid 1-butyl-3-methylimidazolium hydroxide, polyoxometalates, Na{sub 2}SO{sub 4}, and CuSO{sub 4}/K{sub 2}CO{sub 3} under the solvent, the solvent-free or the microwave conditions. These are one and more drowbacks such as long reaction time, use of catalysts, inconvenients due to solid-sate reaction, low yields and limitaion of some carbonyl compounds. On the other hand, H. Sharghi, et al.,14 reported the catalysis of the stereoselectivity of CuSO{sub 4} and K{sub 2}CO{sub 3} in the oximation of aldehydes and ketones under solvent-free conditions. Although this method show high selectivity, it is inconvenient for the large scale experiments and the industrial process due to the solvent-free condition. Therefore, we attempted to develop a more convenient and efficient solution method. According to the literatures, treatment of potassium carbonate with methanol generates slightly the potassium methoxide, which may be useful for forming the free NH{sub 2}OH from its salts. We describe the oximation of aldehyde and ketone using NH{sub 2}OH·HCl/K{sub 2}CO{sub 3} in methanol solvent. We selected oximation of acetophenone (1a) with hydroxylamine hydrochloride as a model and its behavior was investigated in seven solvents involving methanol (Table 1). As shown in the Entry 2 in

  4. Rater agreement in lung scintigraphy

    International Nuclear Information System (INIS)

    Christiansen, F.; Andersson, T.; Rydman, H.; Qvarner, N.; Maare, K.

    1996-01-01

    Purpose: The PIOPED criteria in their original and revised forms are today's standards in the interpretation of ventilation-perfusion scintigraphy. When the PIOPED criteria are used by experienced raters with training in consensus interpretation, the agreement rates have been demonstrated to be excellent. Our purpose was to investigate the rates of agreement between 2 experienced raters from different hospitals who had no training in consensus interpretation. Material and Methods: The 2 raters investigated a population of 195 patients. This group included 72 patients from a previous study who had an intermediate probability of pulmonary embolism and who had also been examined by pulmonary angiography. Results: The results demonstrated moderate agreement rates with a kappa value of 0.54 (0.45-0.63 in a 95% confidence interval), which is similar to the kappa value of the PIOPED study but significantly lower than the kappa values of agreement rates among consensus-trained raters. There was a low consistency in the intermediate probability category, with a proportional agreement rate of 0.39 between the experienced raters. Conclusion: The moderate agreement rates between raters from different hospitals make it difficult to compare study populations of a certain scintigraphic category in different hospitals. Further investigations are mandatory for accurate diagnosis when the scintigrams are in the category of intermediate probability of pulmonary embolism. (orig.)

  5. 76 FR 12563 - Oral Dosage Form New Animal Drugs; Spinosad and Milbemycin Oxime

    Science.gov (United States)

    2011-03-08

    ... spinosad and milbemycin oxime in dogs for the treatment and prevention of flea infestations and for the... and milbemycin oxime) Chewable Tablets in dogs for the treatment and prevention of flea infestations... Friday. Under section 512(c)(2)(F)(ii) of the Federal Food, Drug, and Cosmetic Act (21 U.S.C. 360b(c)(2...

  6. Evaluation of lung injury induced by pingyangmycin with 99Tcm-HMPAO lung imaging

    International Nuclear Information System (INIS)

    Zhao Changjiu; Yang Zhijie; Fu Peng; Zhang Rui

    2005-01-01

    Objective: To investigate the lung uptake of 99 Tc m -hexamethyl propylene amine oxime (HMPAO) in pingyangmycin-induced lung injury and its mechanism. Methods: 24 white rabbits were randomly divided into 4 groups. Group I: the control with normal diet. In group II, III and IV 0.2, 0.3 and 0.5 mg/kg pingyangmycin were given respectively by marginal vein of ear every other day. 99 Tc m -HMPAO static lung imaging was performed before and 8, 16, 24, 32 d after injection of pingyangmycin. 7 pixel x 5 pixel regions of interest (ROIs) were drawn on the right lung(R) and right upper limb(B), R/B were calculated. Also, 2 ml venous blood was withdrawn for measurement of endothelin by radioimmunoassay. 16 d after pingyangmycin in group IV and 32 d in group I, II and III, all the rabbits were sacrificed. Both lungs were examined immediately under light and electron microscopy. Results: Compared with the control group, there were statistical differences of 99 Tc m -HMPAO lung uptake in group II, III and IV (P 99 Tc m -HMPAO lung imaging can detect early pingyangmycin-induced lung injury. The endothelium of lung microcapillary is presumably the main location site of 99 Tc m -HMPAO abnormal concentration. (authors)

  7. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  8. Chromatographic analysis of toxic phosphylated oximes (POX): a brief overview.

    Science.gov (United States)

    Becker, Christian; Worek, Franz; John, Harald

    2010-10-01

    Poisoning with organophosphorus compounds (OP), e.g. pesticides and nerve agents, causes inhibition of acetylcholinesterase (AChE) by phosphylation of the active site serine residue. Consequently, accumulation of stimulating acetylcholine in the synaptic cleft induces cholinergic crisis which ultimately may lead to death. For standard causal therapy, enzyme reactivators are administered representing oxime derivatives of quarternary pyridinium compounds, e.g. pralidoxime (2-PAM), obidoxime and HI 6. The mechanism of action includes removal of the phosphyl moiety by a nucleophilic attack of the oximate molecule substituting the enzyme and forming a phosphylated oxime (POX). POX is produced in stoichiometric amounts of reactivated enzyme and exhibits a significantly enhanced toxicity (inhibition rate constant) when compared to the parent OP. However, stability of POX under physiological conditions appears to be highly limited. Nevertheless, the presence of POX reveals a potential critical issue for both therapeutic efficacy in vivo and pharmacokinetic and pharmacodynamic (PK-PD) modelling based on cholinesterase activity data. Detailed characterization represents an important need for elaboration of the entire oxime pharmacology.Nevertheless, reports on POX toxicity and analysis are quite rare and may therefore be indicative of the challenge of POX analysis. This review provides a concise overview of chromatographic approaches applied to POX separation. Chromatography represents the key technology for POX purification and quantification in kinetic in vitro studies using buffers and biological fluids. Applications based on reversed-phase chromatography (RPC), ion pair chromatography (IPC) and an affinity approach as well as thin layer chromatography (TLC) are discussed and novel applications and data are presented. Copyright © 2010 John Wiley & Sons, Ltd.

  9. Comparison of V/Q SPECT and planar V/Q lung scintigraphy in diagnosing acute pulmonary embolism

    DEFF Research Database (Denmark)

    Borgwardt, Henrik Gutte; Mortensen, Jann; Jensen, Claus Verner

    2010-01-01

    Planar ventilation/perfusion (V/Q) scintigraphy is currently the standard method for the diagnosis of pulmonary embolism (PE) in most nuclear medicine centers. However, recent studies have shown a superior sensitivity and specificity when applying V/Q single photon emission computed tomography...... (SPECT) in diagnosing PE. This study evaluated the diagnostic performance of three-dimensional V/Q SPECT in comparison with planar V/Q scintigraphy....

  10. Gastroesophageal scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Malmud, L.S.; Fisher, R.S.

    1980-01-01

    The technique of gastroesophageal scintigraphy was developed in order to quantitatively detect reflux from the stomach into the esophagus. The scintigraphic technique was compared to previous diagnostic tests. None of the other techniques is as sensitive as gastroesophageal scintigraphy for the detection of reflux, in comparison to the acid reflux test. Gastroesophageal scintigraphy is able to detect gastroesophageal reflux acurately, rapidly, noninvasively, and more sensitively than other diagnostic techniques. In addition, it is able to be employed to quantitate reflux and is suitable for studying the effects of various therapeutic modalities.

  11. Organic Process Technology Valuation: Cyclohexanone Oxime Syntheses

    Science.gov (United States)

    Cannon, Kevin C.; Breen, Maureen P.

    2010-01-01

    Three contemporary processes for cyclohexanone oxime synthesis are evaluated in a case study. The case study introduces organic chemistry students to basic cost accounting to determine the most economical technology. Technical and financial aspects of these processes are evaluated with problem-based exercises that may be completed by students…

  12. Adrenal scintigraphy

    International Nuclear Information System (INIS)

    Beierwaltes, W.H.

    1979-01-01

    The following items are discussed:anatomy and physiology of adrenal glands, clinical indications of scintigraphy, radiobiology and radiochemistry, scintigraphic imaging, adrenocortical hyperfunction, aldosteronism and hypertension associated with low renin level, excess of androgen, adrenocortical hyperfunction and future perspectives of adrenal scintigraphy. (M.A.) [pt

  13. Early detection of interstitial pneumonia by WXGa-citrate scintigraphy. Cases of abnormal pulmonary WXGa uptake with normal chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Shinsaku; Mikami, Riichiro; Ryujin, Yoshitada

    1985-04-01

    In this paper we report our recent experience indicating usefulness of WXGa-citrate scintigraphy in 4 cases with inflammatory pulmonary diseases. These cases showed abnormal pulmonary WXGa uptake with normal chest radiographs. The first case with malignant lymphoma and the second one with lung cancer suffered from pulmonary infection following secondary immuno-insufficiency due to radiotherapy and chemotherapy. Pneumocystis carinii was suspected as causative agent in the first case, and gram negative bacilli in the second case. The third case with lung cancer developed radiation pneumonia after radiotherapy. The fourth case with acute bronchitis developed drug induced interstitial pneumonia presumably due to minocycline administration. It is concluded that WXGa-citrate scintigraphy is more sensitive for early detection of interstitial pneumonia than routine chest radiography.

  14. Inhibition of the voltage-dependent chloride channel of Torpedo electric organ by diisopropylfluorophosphate and its reversal by oximes

    International Nuclear Information System (INIS)

    Abalis, I.M.; Chiang, P.K.; Wirtz, R.A.; Andre, R.G.

    1986-01-01

    Diisopropylfluorophosphate (DFP), a potent organophosphate inhibitor of cholinesterases, was found to inhibit the specific binding of [ 35 S]t-butylbicyclophosphorothionate (TBPS), specific chloride channels ligand, to the electric organ membranes of Torpedo, with a Ki of 21 +/- 3 μM. The binding sites of [ 35 S]TBPS in the Torpedo membranes were found not to be GABA receptors or nicotinic acetylcholine receptors as previously described. Interestingly, a stimulation of the binding of [ 35 S]TBPS was observed in the presence of atropine and three oximes, monopyridinium oxime 2-PAM, bispyridinium bis-oxime TMB-4 and H-oxime HI-6. The maximal stimulation was 300-500% of control, after which, the stimulation was reversed at higher concentrations. The three oximes protected by more than 95% the inhibition by 1 mM DFP of the binding of [ 35 S]TBPS to the voltage-dependent chloride channel. However, atropine protected only 20% of the inhibited channel. These results, thus, suggest that the protection against the toxic effects of DFP or other anticholinesterase agents by the tested oximes may not be solely a result of the reactivation of cholinesterases but also the protection of the voltage-dependent chloride channel

  15. Evaluation of expectoration using aerosol inhalation cine-scintigraphy, 2

    International Nuclear Information System (INIS)

    Ohnuki, Masahiro

    1986-01-01

    Postural drainage and mechanical vibration have been evaluated in 16 patients of stable chronic obstructive pulmonary diseases with copious sputum (daily sputum volume > 50 ml) using aerosol cine-scintigraphy. After inhalation of a 99m Tc-Milli MISA aerosol, the removal of radioactivity from total lung field and selected peripheral lung region was measured during 40 min of (1) resting in the upright position (control), (2) postural drainage (PD), (3) postural drainage with mechanical vibration (PDWV). Compared with the control run, PD significantly improved of mucus clearance on the total lung field (p < 0.001 ∼ 0.01) and peripheral lung region (p < 0.001). However, there was no significant difference between PD and PDWV. Abnormal mucus movement was often recognized, such as stasis at the first carina, main bronchus and trachea, wandering to the lower lung (22.7 %) and regurgitation in the lower lung (50.0 %). The study indicated that postural drainage is an effective form, but mechanical vibration is of no value as an adjunct to postural drainage in the treatment of patients with stable chronic obstructive pulmonary diseases, and it was suggested that there is an adverse effect of postural drainage in the lower lung portion. (author)

  16. The evaluation of the degree of impairment of pulmonary perfusion in lung cancer patients treated by radiotherapy by the quantification of nonuniform distribution of lung perfusion scintigraphy SPECT

    International Nuclear Information System (INIS)

    Mitomo, Osamu; Tsunoda, Takashi; Kuwabara, Hidemasa

    2004-01-01

    By means of quantifying the nonuniform distribution of pulmonary perfusion in Lung Perfusion Scintigraphy SPECT (single photon emission tomography), which is called ''SPECT'' for short, we evaluated the degree of functional impairment of pulmonary perfusion in non-operated lung cancer patients treated by the radiotherapy. Sixty-eight patients with non-operated lung cancer treated with radiotherapy, and who either received or did not receive chemotherapy, from February, 1996 to August, 2002, were examined using SPECT within 6 weeks prior to, or within 2 weeks following radiotherapy. This group was called ''irradiated lung cancer patients''. Twenty-six patients, who were called ''follow-up irradiated lung cancer patients'', were reexamined within four weeks after radiotherapy. On the other hand, 323 patients without lung cancer, who were subdivided into four groups; pulmonary, cardiac, cardio-pulmonary, and non-cardiopulmonary. The SPECT was examined in the supine position after infusing Tc-99m-MAA, 185 MBq in a bolus, mainly into an antecubital vein with the patient's arm elevated. From reconstructed SPECT images, the volume of lung as a whole calculated at 10% of thresholds was assumed to be the ''Baseline Lung Perfusion Volume'' (BPV), and the functional volume rates were calculated in 10% threshold widths from 10% to 100% of the threshold. Assuming the total absolute differences in functional volume rate between each subject and the control to be the distribution index of the lung as a whole (D index), we quantified the degree of nonuniform distribution of the lung as a whole in each subject. In the same way, the distribution index of the left or right lung respectively was calculated as D l or D r index assuming the volume of left or right lung were calculated at 10% of the threshold as left or right BPV and calculating the functional volume rates of each lung in 10% threshold widths from 10% to 100% of the threshold. The D index of irradiated lung cancer

  17. Adrenal scintigraphy

    International Nuclear Information System (INIS)

    Veen, E.A. van der.

    1978-01-01

    The visualization of functioning adrenocortical tissue by scintigraphy became possible with the introduction of radioiodinated cholesterol derivatives. According to the literature, there is evidence that one of these iodinated cholesterols, 6-β-iodomethyl-nor-cholesterol, concentrates in the adrenal cortex to a much greater extent than 131 I-19-odocholesterol. Results comparing both radiopharmaceuticals are described. The authors investigated the possibility of increasing the uptake of iodinated cholesterol using simultaneous ACTH and the 'cholesterol side-chain cleavage enzymeblocker': aminoglutethimide. The results of adrenal scintigraphy performed in 37 patients are described. Finally, the literature on adrenal scintigraphy is reviewed, and results reported in various studies are compared. (Auth.)

  18. Bone marrow scintigraphy vs bone scintigraphy and radiography in multiple myeloma

    International Nuclear Information System (INIS)

    Feggi, M.; Prandini, N.; Orzincolo, C.; Bagni, B.; Scutellari, P.N.; Spanedda, R.; Gennari, M.; Scapoli, C.L.

    1988-01-01

    The radiography patterns of the skeleton of 73 patients affected by multiple myeloma (MM) were compared to the correspondent scintigraphic findings. Whole body scans were performed using Tc-diphosphonates 99m (bone scintigraphy). And Tc-microcolloides 99m (bone marrow scintigraphy). The results indicate that: a) radiography is more sensitive and accurate than scintigraphy in detecting typical myeloma-related bone lesions; b) bone scintigraphy is useful in detecting alterations in particular locations-i.e. sternum, ribs, scapulae, etc.-which are difficult to demonstrate by plain X-rays; moreover, the recovery of the fractures can be visualized; c) bone marrow scintigraphy is employed to demonstrate the presence of marrow expasion, of cold/hot spots, and relative marrow uptake, related to phagocytic activity. Since in adult men red marrow is confined to the epiphysis of long bones and to the spine, all the diseases affecting bone marrow cause medullary expansion/reduction, which are both easily detected by specific radiopharmaceuticals. The peripheral expasions is clearly documented especially in distal humeri and femora since marrow uptake is included, in healthy adults, in the axial and proximal appendicular skeleton. In spite of its yielding unique informetion, bone marrow scintigraphy remains an additional technique of bone scan, because of its low diagnoditc accuracy

  19. Tc99m glucoheptonate in detection of lung tumors

    International Nuclear Information System (INIS)

    Pfeiff, D.N.E.; Nascimento, C.B.L.; Riesgo, A.; Ferreira, E.D.; Kwiatowski, A.; Bornemann, C.

    1989-01-01

    The authors intended, with this study, the use and the efficacy of pulmonary scintigraphy with GHA Tc99 as auxiliary method in the diagnosis of lung tumors. Fifty-five patients were studied clinically and radiologically and afterwards with GHA Tc99 pulmonary scintigraphy. The data were confronted with pathologic findings. In thirty-nine of this patients the isotope were captivate in the place of the tumour. (author) [pt

  20. Lung perfusion scintigraphy in congenital heart disease

    International Nuclear Information System (INIS)

    Sugimura, Hiroshi; Nagamachi, Shigeki; Hoshi, Hiroaki; Jinnouchi, Seishi; Oonishi, Takashi; Futami, Shigemi; Watanabe, Katsushi

    1990-01-01

    Lung perfusion scintigrams were reviewed retrospectively in 28 patients with congenital heart disease, whose ages ranged from the first year to 16 years with an average age of 5 years and 6 months. Seventy four MBq (2 mCi), 111 MBq (2 mCi), and 185 MBq (5 mCi) of Tc-99m macroaggregated albumin were iv injected in the age groups of 0-3, 4-11, and more than 11 years, respectively. Five minutes later, images were obtained in six projections. Abnormal findings on lung perfusion scintigrams were observed in 13 patients (46%). Of these patients, 8 (29%) had a partially decreased blood flow and 5 (17%) had a decreased blood flow in the unilateral lung. No significant difference in the occurrence of abnormal findings was observed among the age groups, although they tended to occur in younger patients. Sex, underlying conditions, and hemodynamics were also independent of scintigraphically abnormal findings. Even when classifying the patients as having either cyanotic or non-cyanotic heart disease, no significant difference in hemodynamics was observed between the group of abnormal findings and the group of normal findings. Pulmonary arteriography available in all patients failed to reveal abnormal findings, with the exception of pulmonary artery stenosis in 2 patients that corresponded to a decreased blood flow in the unilateral lung. Pulmonary artery stenosis seemed to be responsible for abnormal pulmonary blood flow, although other causes remained uncertain. (N.K.)

  1. Preparation of phenacylchloride, morpholinophenacyl and N-Piperidinophenacyl oximes and study of their complexation with Copper (II) and Cobalt (II) ions

    International Nuclear Information System (INIS)

    Ali, Kamal Eldin Ahmed

    1999-01-01

    The aim of the present work is to prepare phenacyl chloride oxime and phenacyl of N-Piperidine and morpholine derivatives, and mainly to study their complexes with Cu(II) and Co(II) ions with objective ascertaining that one of these ligands can be used in quantitative extraction of these metal ions from the aqueous solution. Copper (II) salts form 1:1 complexes with the phenyacyl oximes of N-piperidine and morpholine and 1:2 complex with phenacyl chloride oxime. However, cobalt(II) salts form 1:2 complexes with phenacyl oxime of N-piperidine and morpholine but does not complex with phenacyl chloride oxime. The stoichiometry of these complexes were determined by UV/VIS spectrophotometry using the mole ratio, continuous variation and slope ratio methods.The stability constants of the five complexes were calculated from aberrances using Job's method. They showed that the copper (II) and cobalt (II) complexes with N-piperidinophenacy oxime are more stable than those with morpholinophenacyl oxime. Copper (II) complexes with any of these two ligands are more stable than those of cobalt (II). IR spectra of the complexes of copper (II) and cobalt (II) with phenacyl oxime of N-piperidine and morpholine show diminished peaks of hydrogen bonds between N and O atoms of the ligand. Specific extractabilities using amylalcohol of copper (II) complexes with the three ligands increase from PH4 to reach its maximum at PH8. The high value for N-piperidinophenacyl oxime ligand (96%-97%) indicates that, this ligand can be used as analytical reagent for the quantitative spectrophotometric determination of copper (II) salts in aqueous media. Cobalt (II) complexes were formed and extracted from solution only at PH6 (specific PH). The extractabilities ranging from 81.6-87.2% warrants the use of these ligands in quantitative spectrophotometric determination of cobalt (II).(Author)

  2. Deprotection of oximes using urea nitrate under microwave irradiation

    Indian Academy of Sciences (India)

    Abstract. A new mild and efficient method for the cleavage of oximes to carbonyl compounds using readily available urea nitrate in acetonitrile-water (95 : 5), under microwave irradiation within 2 min, in good yields is reported.

  3. Evaluation of mosaic pattern areas in HRCT with Min-IP reconstructions in patients with pulmonary hypertension: Could this evaluation replace lung perfusion scintigraphy?

    International Nuclear Information System (INIS)

    Rossi, A.; Attinà, D.; Borgonovi, A.; Buia, F.; De Luca, F.; Guidalotti, P.L.; Fughelli, P.; Galiè, N.; Zompatori, M.

    2012-01-01

    Purpose: The aim of this study is to evaluate a possible correlation between areas of lung attenuation, found in minimum intensity projection (Min-IP) reconstruction images performed with high resolution computed tomography without contrast medium (HRCT), and areas of lung perfusion alteration, found in lung perfusion scintigraphy (LPS). Materials and methods: Two independent radiologists, unaware of LPS results, evaluated retrospectively a group of 113 patients affected by pulmonary hypertension (HP) of different aetiology. These have been examined in a period of two years in our centre both by spiral computed tomography (CT) with and without contrast-medium and by LPS. The final diagnosis was determined on clinical data, right heart catheterisation and contrast enhanced CT in angiographic phase (CTPA). We reconstructed the Min-IP images of lung parenchyma in all the cases both in HRCT without contrast-medium, and in contrast enhanced CT in angiographic phase (CTPA) in axial, sagittal and coronal planes. The obtained images were qualitatively graded into three categories of pulmonary attenuation: homogeneous, inhomogeneous with non-segmental patchy defects, inhomogeneous with segmental defects. The same criteria of classification were used also for LPS images. In the group of patients with chronic thromboembolic pulmonary hypertension (CTEPH) we also compared the number of areas of lung attenuation found in Min-IP images in HRCT without contrast-medium, and their exact localization, with not perfused areas in LPS. Gold standard for the diagnosis of pulmonary embolism was spiral contrast enhanced CT in angiographic phase (CTPA). Results: In all cases we found exact correspondence between the Min-IP images in HRCT with and without contras agent. The attenuation pattern seen on Min-IP images was concordant with those of LPS in 96 out of 113 patients (85%). In the remaining 17 cases (15%) it was discordant: in 12 cases inhomogeneous in Min-IP images (7 with non

  4. Skeleton scintigraphy in trauma

    International Nuclear Information System (INIS)

    Ansari, M.

    2002-01-01

    Skeletal trauma is common and presents both an opportunity and a problem in skeletal scintigraphy. The opportunity arises in the ability of skeletal scintigraphy to demonstrate abnormalities early after direct trauma. It is well recognized that the early detection of fractures in some sites cannot be reliably achieved by standard radiography, especially in the femoral neck and scaphoid bone. The problem comes in recognizing the effects of skeletal trauma when using skeletal scintigraphy for another purpose, such as the detection of metastatic disease. iatrogenic trauma to either the skeleton or soft tissues may be manifest scintigraphic ally. For example Craniotomy typically leaves a rim pattern at the surgical margin. Rib Retraction during thoracotomy can elicit periosteal reaction. Areas of the skeletal receiving curative levels of ionizing radiation (typically 4000 rads or greater) characteristically demonstrate decreased uptake within 6 months to 1 year after therapy. The generally high sensitivity of the skeletal scintigraphy seems to make it an ideal survey test in cases of suspected child abuse especially in which radiographs are unrevealing. Because of difficulties in obtaining a history of trauma from a preschool child or even eliciting a satisfactory description of the location and nature of the pain, skeletal scintigraphy provides a simple and reliable investigation in these children. Subtle trauma, such as that from stress fractures is often difficult to visualize on a plain radiograph. Skeletal scintigraphy is frequently positive at the time of clinical presentation. Skeletal scintigraphy is exquisitely sensitive to the remodeling process and typically shows abnormalities 1 to 2 weeks or more before the appearance of radiographic changes in stress fractures. The periosteal reaction can be visualized within hours of the injury. Insufficiency and fatigue fractures such as vertebral compression fracture, which is probably the most common consequence of

  5. Clinical studies on combined ventilation (sup(81m)Kr)/perfusion (sup(99m)Tc-MAA) scintigraphy

    International Nuclear Information System (INIS)

    Yamamoto, Keiichiro; Miyamae, Tatsuya

    1983-01-01

    One hundred fifty patients having pulmonary disease underwent pulmonary scintigraphy sequentially with sup(99m)Tc-MAA and sup(81m)Kr gases. Scintigrams of matched defect were obtained from 113 (75.3%) of the 150 patients, considered to be nonspecific universal pattern of a pulmonary disease. Scintigrams of mismatched defect (absent perfusion and homogeneous ventilation) were obtained from 20 patients (13.3%), including 6 with lung carcinoma, 3 with pulmonary embolism, 3 with connective tissue disease, 2 with aortitis syndrome and 6 with other diseases. Scintigrams of mismatch with impaired ventilation and normal perfusion were mainly seen in chronic obstructive lung diseases. Of the 10 patients with bronchial asthma, 5 had scintigrams of improved ventilation after intravenous injection of 250 mg aminophilline, but none of patients with emphysema. The combined scintigraphy has made significant contributions to diagnosis and management of patients with pulmonary disease where the chest X-ray is unhelpful. (author)

  6. How useful is gastroesophageal reflux scintigraphy in suspected childhood aspiration?

    International Nuclear Information System (INIS)

    Fawcett, H.D.; Adams, J.C.; Hayden, C.K.; Swischuk, L.E.

    1988-01-01

    It has been suggested that gastroesophageal reflux scintigraphy might be useful in assisting one in determining therapy for patients suspected of aspirating or becoming apneic secondary to gastroesophageal reflux. This, however, has not been our experience and in reviewing 23 patients with recurrent pneumonia and/or apnea who had gastroesophageal reflux scintigraphy, we were able to detect aspiration in only one. This was especially significant since 13 (59%) of these patients had demonstrable reflux, and of these, eight were treated successfully for suspected aspiration even though none was demonstrated isotopically. To be sure, the demonstration of pulmonary aspiration with gastroesophageal reflux scintigraphy had little influence on patient selection and response to therapy. For this reason we feel there is little justification in depending on the GRS for the specific purpose of trying to document pulmonary aspiration in infants and children who are refluxing. One of the more serious complications of gastroesophageal (GE) reflux is aspiration leading to recurrent pulmonary infections and/or apnea. However, it always has been difficult to demonstrate actual aspiration into the lungs, and to be sure, barium studies of the upper GI tract seldom reveal this complication. Recently, however, considerable interest has been generated in gastroesophageal scintigraphy (GRS) as a possible means of documenting such aspiration. Rationale for this stems from the fact that suspected patients can be studied over a longer period of time and in addition, delayed and overnight images can be obtained. However, our experience does not support GRS as being an adequate method for demonstrating aspiration. (orig.)

  7. How useful is gastroesophageal reflux scintigraphy in suspected childhood aspiration

    Energy Technology Data Exchange (ETDEWEB)

    Fawcett, H.D.; Adams, J.C.; Hayden, C.K.; Swischuk, L.E.

    1988-05-01

    It has been suggested that gastroesophageal reflux scintigraphy might be useful in assisting one in determining therapy for patients suspected of aspirating or becoming apneic secondary to gastroesophageal reflux. This, however, has not been our experience and in reviewing 23 patients with recurrent pneumonia and/or apnea who had gastroesophageal reflux scintigraphy, we were able to detect aspiration in only one. This was especially significant since 13 (59%) of these patients had demonstrable reflux, and of these, eight were treated successfully for suspected aspiration even though none was demonstrated isotopically. To be sure, the demonstration of pulmonary aspiration with gastroesophageal reflux scintigraphy had little influence on patient selection and response to therapy. For this reason we feel there is little justification in depending on the GRS for the specific purpose of trying to document pulmonary aspiration in infants and children who are refluxing. One of the more serious complications of gastroesophageal (GE) reflux is aspiration leading to recurrent pulmonary infections and/or apnea. However, it always has been difficult to demonstrate actual aspiration into the lungs, and to be sure, barium studies of the upper GI tract seldom reveal this complication. Recently, however, considerable interest has been generated in gastroesophageal scintigraphy (GRS) as a possible means of documenting such aspiration. Rationale for this stems from the fact that suspected patients can be studied over a longer period of time and in addition, delayed and overnight images can be obtained. However, our experience does not support GRS as being an adequate method for demonstrating aspiration.

  8. Changes in perfusion scintigraphy in the first days of heparin therapy in patients with acute pulmonary embolism

    NARCIS (Netherlands)

    de Groot, M. R.; Oostdijk, A. H.; Engelage, A. H.; van Marwijk Kooy, M.; Büller, H. R.

    2000-01-01

    Patients with suspected pulmonary embolism often receive heparin therapy for hours to days before ventilation/perfusion scintigraphy is completed. We assessed to what extent the lung scan classification and pulmonary vascular perfusion changed over a period of 2-4 days of full anticoagulant therapy.

  9. Conversion of Natural Aldehydes from Eucalyptus citriodora, Cymbopogon citratus, and Lippia multiflora into Oximes: GC-MS and FT-IR Analysis †

    Directory of Open Access Journals (Sweden)

    Igor W. Ouédraogo

    2009-08-01

    Full Text Available Three carbonyl-containing extracts of essential oils from Eucalyptus citriodora (Myrtaceae, Cymbopogon citratus (Gramineae and Lippia multiflora (Verbenaceae were used for the preparation of oximes. The reaction mixtures were analyzed by GC-MS and different compounds were identified on the basis of their retention times and mass spectra. We observed quantitative conversion of aldehydes to their corresponding oximes with a purity of 95 to 99%. E and Z stereoisomers of the oximes were obtained and separated by GC-MS. During GC analysis, the high temperature in the injector was shown to cause partial dehydratation of oximes and the resulting nitriles were readily identified. Based on FT-IR spectroscopy, that revealed the high stability and low volatility of these compounds, the so-obtained oximes could be useful for future biological studies.

  10. Peripheral site ligand conjugation to a non-quaternary oxime enhances reactivation of nerve agent-inhibited human acetylcholinesterase

    NARCIS (Netherlands)

    Koning, M.C. de; Grol, M. van; Noort, D.

    2011-01-01

    Commonly employed pyridinium-oxime (charged) reactivators of nerve agent inhibited acetylcholinesterase (AChE) do not readily pass the blood brain barrier (BBB) because of the presence of charge(s). Conversely, non-ionic oxime reactivators often suffer from a lack of reactivating potency due to a

  11. Evaluation of patients undergoing lung volume reduction surgery: Ancillary information available from computed tomography

    International Nuclear Information System (INIS)

    Cleverley, Joanne R.; Desai, Sujal R.; Wells, Athol U.; Koyama, Hiroshi; Eastick, Sian; Schmidt, Maria A.; Charrier, Clare L.; Gatehouse, Peter D.; Goldstraw, Peter; Pepper, John R.; Geddes, Duncan M.; Hansell, David M.

    2000-01-01

    AIM: A number of imaging techniques have been used for the pre-operative assessment of patients for lung volume reduction surgery (LVRS). We evaluated whether data currently acquired from perfusion scintigrams and cine MR of the diaphragm are obtainable from high resolution CT (HRCT) of the thorax. MATERIALS AND METHODS: Thirty patients taking part in a randomized controlled trial of LVRS against maximal medical therapy were evaluated. HRCT examinations (n= 30) were scored for (i) the extent and distribution of emphysema; (ii) the extent of normal pulmonary vasculature; and (iii) diaphragmatic contour, apparent defects and herniation. On scintigraphy, (n28), perfusion of the lower thirds of both lungs, as a proportion of total lung perfusion (LZ/T PERF ), was expressed as a percentage of predicted values (derived from 10 normal control subjects). On cine MR (n= 25) hemidiaphragmatic excursion and coordination were recorded. RESULTS: Extensive emphysema was present on HRCT (60% ± 13.2%). There was strong correlation between the extent of normal pulmonary vasculature on HRCT and on perfusion scanning (r s = 0.85, P< 0.00005). Hemidiaphragmatic incoordination on MR was weakly associated with hemidiaphragmatic eventration on HRCT (P0.04). CONCLUSION: The strong correlation between lung perfusion assessed by HRCT and lung perfusion on scintigraphy suggests that perfusion scintigraphy is superfluous in the pre-operative evaluation of patients with emphysema for LVRS. Cleverley, J.R. (2000)

  12. Synthesis of 2-hydroxy-3-(2-methyl-propenyl-1,4-naphthoquinone and related oxime derivatives

    Directory of Open Access Journals (Sweden)

    Patricia S. Oliveira

    2012-06-01

    Full Text Available The condensation reaction of commercial 2-hydroxy-1 ,4-naphthoquinone 1 (lawsone with isobutyraldehyde 2 furnishs norlapachol 3 (2-hydroxy-3-(2-methyl-propenyl -1,4-naphthoquinone with yields ranging from 66 to 93% depending on the different conditions tested, and a reaction temperature factor determinant for the formation of the desired product. It was treated with hydroxylamine hydrochloride in alkaline (NaOH to provide the oxime 4 from regioselective modification of the carbonyl C-1 with 91% yield. The regioselectivity of the reaction can be explained by analyzing the different resonance structures which can be seen that the carbonyl C-4 is less electrophilic than C-1. In this work was also obtained the oxime 5, 6 and 7 from lapachol, αlpha and β-lapachone, respectively, in yields of 64-85%. The oximes of αlpha and β-norlapachone, 8 and 9 are in obtention. All the products were analyzed by IR and NMR, and were observed that oximes of lapachol and norlapachol are isolated as E/Z mixtures. Two-dimensional NOE-type experiments of the corresponding acylated derivative will be made to help identify the proportion of the mixture.

  13. Metastatic superscan on 99mTc-MDP bone scintigraphy in a case of carcinoma colon: Common finding but rare etiology

    International Nuclear Information System (INIS)

    Chakraborty, Partha Sarathi; Sharma, Punit; Karunanithi, Sellam; Bal, Chandrasekhar; Kumar, Rakesh

    2014-01-01

    Bone scintigraphy in which there is excessive skeletal radioisotope uptake in relation to soft tissues along with absent or faint activity in the genitourinary tract is known as a ‘superscan’. Prostate cancer is the most common malignancy associated with superscan along with others such as lung cancer, breast cancer and haematological malignancies. Here we present the case of a 41 year old woman with carcinoma colon with metastatic superscan on 99m Tc-MDP bone scintigraphy, a very rare cause for metastatic superscan

  14. Diagnostic value of 99mTc-ethambutol scintigraphy in tuberculosis: compared to microbiological and histopathological tests.

    Science.gov (United States)

    Kartamihardja, A H S; Kurniawati, Y; Gunawan, R

    2018-01-01

    Tuberculosis (TB) still remains the world's endemic infection. TB affects the lungs and any part of the body other than the lung. The diagnosis of TB has not changed much over the decades. Ethambutol is one of the first line treatments for TB. It can be labeled using 99m Tc. 99m Tc-ethambutol will be accumulated in the site of TB lesion and can be imaged using gamma camera. The aim of this study was to evaluate the diagnostic value of 99m Tc-ethambutol scintigraphy in detecting and localizing of TB. Retrospective cross-sectional study was done. Subjects were patients suspected of having TB infection. Whole body and SPECT-CT imaging at the suspected area was done 1 and 4 h after injection of 370-555 MBq 99m Tc-ethambutol. 99m Tc-ethambutol scintigraphy was analyzed visually. The results were compared with that of histopathological or microbiological tests. Statistical analysis was done to determine the sensitivity, specificity, PPV, NPV and accuracy. One hundred and sixty-eight subjects were involved in this study. There were 110 men and 58 women with mean age of 34.52 ± 11.94 years. There were concordance results in 156 (92.86%) and discordant in 12 (7.14%) subjects between 99m Tc-ethambutol scintigraphy and histopathological or microbiological result. The sensitivity, specificity, PPV, NPV and accuracy of 99m Tc-ethambutol scintigraphy in the diagnosis of pulmonary TB were 93.9, 85.7, 93.9, 85.7 and 91.4%, respectively, for extra-pulmonary TB 95.5, 77.8, 97.9, 63.6, and 85.1%, respectively, and for total tuberculosis 94.9, 83.3, 96.3, 78.1 and 92.8%, respectively. There was no side effect observed in this study. 99m Tc-ethambutol scintigraphy is a useful diagnostic imaging technique to detect and localize intra- and extra-pulmonary TB. It is safe to be performed even in pediatric patient. Consuming ethambutol less than 2 weeks did not influence the result.

  15. Estimation of pulmonary hypertension in lung and valvular heart diseases by perfusion lung scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige [Shinshu Univ., Matsumoto, Nagano (Japan). School of Allied Medical Sciences; Tanaka, Masao; Yazaki, Yoshikazu; Kitabayashi, Hirosi; Koizumi, Tomonori; Kubo, Keisi; Sekiguchi, Morie; Yano, Kesato

    1999-06-01

    To estimate pulmonary hypertension, we measured postural differences in pulmonary blood flow for the lateral decubitus positions on perfusion lung scintigrams with Tc-99 m macro-aggregated albumin, applying the method devised by Tanaka et al (Eur J Nucl Med 17: 320-326, 1990). Utilizing a scintillation camera coupled to a minicomputer system, changes in the distribution of pulmonary blood flow caused by gravitational effects, namely, changes in the total count ratios for the right lung versus the left lung in the right and left lateral decubitus positions (R/L), were obtained for 44 patients with lung disease, 95 patients with valvular heart disease, and 23 normal subjects. Mean standard deviation in the R/L ratios was 3.09{+-}1.28 for the normal subjects, 1.97{+-}0.89 for the patients with lung disease, and 1.59{+-}0.59 for the patients with valvular heart disease. The R/L ratios correlated with mean pulmonary arterial pressure and cardio-thoracic ratios in the lung disease and valvular heart disease groups, with pulmonary arteriolar resistance in the former, and with pulmonary capillary wedge pressure in the latter. Defining pulmonary hypertension (>20 mmHg) as an R/L ratio of less than 1.81, which is the mean-1 standard deviation for normal subjects, the sensitivity and the specificity of the R/L ratio for the diagnosis of pulmonary hypertension were 62.9% and 76.2%, respectively, for the lung disease patients, and 80.3% and 61.8%, respectively, for the valvular heart disease patients. This method seems to be useful for the pathophysiologic evaluation of pulmonary perfusion in cases of lung disease and valvular heart disease. (author)

  16. Estimation of pulmonary hypertension in lung and valvular heart diseases by perfusion lung scintigraphy

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Yazaki, Yoshikazu; Kitabayashi, Hirosi; Koizumi, Tomonori; Kubo, Keisi; Sekiguchi, Morie; Yano, Kesato

    1999-01-01

    To estimate pulmonary hypertension, we measured postural differences in pulmonary blood flow for the lateral decubitus positions on perfusion lung scintigrams with Tc-99 m macro-aggregated albumin, applying the method devised by Tanaka et al (Eur J Nucl Med 17: 320-326, 1990). Utilizing a scintillation camera coupled to a minicomputer system, changes in the distribution of pulmonary blood flow caused by gravitational effects, namely, changes in the total count ratios for the right lung versus the left lung in the right and left lateral decubitus positions (R/L), were obtained for 44 patients with lung disease, 95 patients with valvular heart disease, and 23 normal subjects. Mean standard deviation in the R/L ratios was 3.09±1.28 for the normal subjects, 1.97±0.89 for the patients with lung disease, and 1.59±0.59 for the patients with valvular heart disease. The R/L ratios correlated with mean pulmonary arterial pressure and cardio-thoracic ratios in the lung disease and valvular heart disease groups, with pulmonary arteriolar resistance in the former, and with pulmonary capillary wedge pressure in the latter. Defining pulmonary hypertension (>20 mmHg) as an R/L ratio of less than 1.81, which is the mean-1 standard deviation for normal subjects, the sensitivity and the specificity of the R/L ratio for the diagnosis of pulmonary hypertension were 62.9% and 76.2%, respectively, for the lung disease patients, and 80.3% and 61.8%, respectively, for the valvular heart disease patients. This method seems to be useful for the pathophysiologic evaluation of pulmonary perfusion in cases of lung disease and valvular heart disease. (author)

  17. Radiolabeled somatostatin analog scintigraphy in oncology and immune diseases: an overview

    International Nuclear Information System (INIS)

    Kwekkeboom, D.J.; Krenning, E.P.

    1997-01-01

    [ 111 In-DTPA-D-Phe 1 [-octreotide is a new radiopharmaceutical with a great potential for the visualization of somatostatin receptor-positive tumors, granulomas, and diseases in which activated leukocytes play a role. The overall sensitivity of [ 111 In-DTPA-D-Phe 1 [-octreotide scintigraphy to localize neuroendocrine tumors is high. In several neuroendocrine tumor types, inclusion of somatostatin receptor imaging in the localization or staging procedure may be very rewarding, either in terms of cost-effectiveness, patient management, or quality of life. In our opinion, this holds true for patients with carcinoids, gastrinomas, paragangliomas, small-cell lung carcinoma, and selected cases of patients with insulinomas. The value of [ 111 In-DTPA-D-Phe 1 [-octreotide scintigraphy in patients with other tumors, such as breast cancer, malignant lymphomas, or in patients with granulomatous diseases, has to be established. (orig.). With 4 figs., 1 tab

  18. The predictive value of preoperative perfusion/ventilation scintigraphy, spirometry and x-ray of the lungs on postoperative pulmonary complications. A prospective study

    International Nuclear Information System (INIS)

    Fogh, J.; Wille-Joergensen, P.; Brynjolf, I.; Thorup, J.; Joergensen, T.; Bording, L.; Kjaergaard, J.

    1987-01-01

    Prospectively, 125 patients were examined with 99m Tc-perfusion scintigraphy, 89m Kr- or 127 Xe-ventilation scintigraphy and chest radiogram prior to major surgery. Postoperative therapy-demanding pulmonary complications occurred in 18% of the patients. A statistical association could be demonstrated between all the preoperative tests except ventilation scintigraphy and the frequency of complications. However, the predictive values of each of the tests, or even the combined results, were not significantly different from the frequency of complications among all the patients. It is concluded that the predictive values of perfusion-and ventilation scintigraphy, spirometry and radiogram of the chest are too low to be of any practical use. (author)

  19. Usefulness of hybrid SPECT/CT for the 99mTc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis

    Directory of Open Access Journals (Sweden)

    Chiara Bruni

    Full Text Available Cranial osteomyelitis is a potentially fatal lesion. White blood cell scanning (WBC with 99mTc-hexamethylpropylene amine oxime (HMPAO has proven highly sensitive and specific in the diagnosis and follow-up of patients with suspected osteomyelitis. In this report we show the usefulness of SPECT and transmission CT performed simultaneously using a hybrid imaging device for the functional anatomic mapping of soft tissue and cranial bone infections. 99mTc-HMPAO-labeled leukocytes scintigraphy was performed on an elderly diabetic man with an intracranial mass lesion and with suspected temporal bone infection. Planar scans were acquired 30 min, 4 h, and 24 h after injection. SPECT/CT was obtained 6 h after tracer injection, using a dual-head camera coupled with a low-power X-ray tube. The scintigraphic results were matched with the results of surgery and of clinical follow-up. The planar images alone were true-positives for abscess in this patient. SPECT/CT improves the accuracy of99mTc-HMPAO scintigraphy especially in discriminating between soft-tissue and bone involvement. In fact, SPECT/CT also showed temporal bone osteomyelitis. This result indicates that SPECT/CT performed using a hybrid device can improve imaging with 99mTc-HMPAO-labeled leukocytes in patients with suspected osteomyelitis by providing accurate anatomic localization and precise definition of the extent of infection.

  20. Scintigraphy in a case of Churg-Strauss vasculitis with myocardial involvement using 111In-labelled antimyosin

    International Nuclear Information System (INIS)

    Krause, T.; Schuemichen, C.; Beck, A.; Moser, E.; Lang, B.; Hohnloser, S.

    1990-01-01

    A case of Churg-Strauss vasculitis in a young woman is reported. Diagnosis was confirmed by muscle biopsy. Affection of lungs, kidneys and skin was evident. In addition, myocarditis was suspected on clinical evidence. A highly positive scintigraphy with 111 In-antimyosin enabled diagnosis and assessment of damage to the myocytes. With a heart-to-lung ratio of 3.0 the accumulated activity in the myocardium was higher than usually found in myocarditis. This finding supports the hypothesis of an additional ischemic necrosis. (orig.) [de

  1. An application of semiquantitative analysis of pulmonary scintigraphy to pulmonary tuberculosis sequelae

    International Nuclear Information System (INIS)

    Uchida, Kou; Miyasaka, Takashi; Nakayama, Hiroyuki; Suganuma, Yasuaki; Sim, Jae-Joon; Takahashi, Hideki; Takano, Masaaki; Kawata, Kanemitsu.

    1996-01-01

    We performed ventilation-perfusion scintigraphy in 13 patients with pulmonary tuberculosis sequelae and 21 with chronic obstructive pulmonary disease. We used 99m Tc-MAA for perfusion scintigram and 133 Xe gas for ventilation scintigram. We added the radioactivities during the rebreathing phase of the ventilation scintigram to make a computerized image of the lung volume. Regions of interest (ROIs) were derived from radioactivities on each image. ROIs included each whole lung on lung volume (L) image and areas where radioactivity was greater than 70% of the highest radioactivity on perfusion (P70) image. We counted the area of ROIs on L and P70, and used the ratio of perfusion to lung volume (P70/L) as a parameter of pulmonary perfusion. P70/L in patients with pulmonary tuberculosis sequelae was significantly higher than that in those with COPD. This suggested that the area of high pulmonary perfusion is larger in the patients with pulmonary tuberculosis sequelae as compared with those with COPD. (author)

  2. A comprehensive evaluation of the efficacy of leading oxime therapies in guinea pigs exposed to organophosphorus chemical warfare agents or pesticides

    Energy Technology Data Exchange (ETDEWEB)

    Wilhelm, Christina M., E-mail: wilhelmc@battelle.org [Battelle, 505 King Avenue, JM-7, Columbus, OH 43201-2693 (United States); Snider, Thomas H., E-mail: snidert@battelle.org [Battelle, 505 King Avenue, JM-7, Columbus, OH 43201-2693 (United States); Babin, Michael C., E-mail: babinm@battelle.org [Battelle, 505 King Avenue, JM-7, Columbus, OH 43201-2693 (United States); Jett, David A., E-mail: jettd@ninds.nih.gov [National Institutes of Health/National Institute of Neurological Disorders and Stroke, Bethesda, MD 20892 (United States); Platoff, Gennady E., E-mail: platoffg@niaid.nih.gov [National Institutes of Health/National Institute of Allergy and Infectious Diseases, Bethesda, MD 20892 (United States); Yeung, David T., E-mail: dy70v@nih.gov [National Institutes of Health/National Institute of Neurological Disorders and Stroke, Bethesda, MD 20892 (United States)

    2014-12-15

    The currently fielded pre-hospital therapeutic regimen for the treatment of organophosphorus (OP) poisoning in the United States (U.S.) is the administration of atropine in combination with an oxime antidote (2-PAM Cl) to reactivate inhibited acetylcholinesterase (AChE). Depending on clinical symptoms, an anticonvulsant, e.g., diazepam, may also be administered. Unfortunately, 2-PAM Cl does not offer sufficient protection across the range of OP threat agents, and there is some question as to whether it is the most effective oxime compound available. The objective of the present study is to identify an oxime antidote, under standardized and comparable conditions, that offers protection at the FDA approved human equivalent dose (HED) of 2-PAM Cl against tabun (GA), sarin (GB), soman (GD), cyclosarin (GF), and VX, and the pesticides paraoxon, chlorpyrifos oxon, and phorate oxon. Male Hartley guinea pigs were subcutaneously challenged with a lethal level of OP and treated at approximately 1 min post challenge with atropine followed by equimolar oxime therapy (2-PAM Cl, HI-6 DMS, obidoxime Cl{sub 2}, TMB-4, MMB4-DMS, HLö-7 DMS, MINA, and RS194B) or therapeutic-index (TI) level therapy (HI-6 DMS, MMB4-DMS, MINA, and RS194B). Clinical signs of toxicity were observed for 24 h post challenge and blood cholinesterase [AChE and butyrylcholinesterase (BChE)] activity was analyzed utilizing a modified Ellman's method. When the oxime is standardized against the HED of 2-PAM Cl for guinea pigs, the evidence from clinical observations, lethality, quality of life (QOL) scores, and cholinesterase reactivation rates across all OPs indicated that MMB4 DMS and HLö-7 DMS were the two most consistently efficacious oximes. - Highlights: • First comprehensive evaluation of leading AChE oxime reactivators • All oximes are compared against current U.S. therapy 2-PAM Cl. • Relative therapeutic oxime efficacies against OP CWNA and pesticides • Contribution to more effective

  3. Liver and spleen scintigraphy

    International Nuclear Information System (INIS)

    Devries, D.F.

    1988-01-01

    Since the introduction of liver and spleen scintigraphy in the early 1950s, it has undergone considerable changes, the most notable being technetium 99m sulfur colloid, the gamma camera, and single photon emission computed tomography (SPECT). What is the role f liver-spleen scintigraphy in this high-technology society? This chapter attempts to address this question by looking at the radiopharmaceuticals, the technique, and most importantly, the application of scintigraphy to the diagnosis of focal and diffuse hepatic and splenic disease

  4. Radionuclide scintigraphy in the evaluation of gastroesophageal reflux in symptomatic and asymptomatic pre-term infants

    Energy Technology Data Exchange (ETDEWEB)

    Morigeri, C.; Mukhopadhyay, K.; Narang, A. [Postgraduate Institute of Medical Education and Research (PGIMER), Division of Neonatology, Department of Paediatrics, Chandigarh (India); Bhattacharya, A.; Mittal, B.R. [Postgraduate Institute of Medical Education and Research (PGIMER), Department of Nuclear Medicine, Chandigarh (India)

    2008-09-15

    Gastroesophageal reflux (GER) is very common in pre-term infants. The diagnosis based on symptoms is always questionable. The incidence of GER in symptomatic babies varies from 22% to 85%, but literature regarding the incidence of reflux in asymptomatic pre-term infants is lacking. We used radionuclide scintigraphy to evaluate the incidence of GER in symptomatic as well as asymptomatic pre-term neonates and to assess whether symptoms have any relation with positive scintigraphy. We studied 106 pre-term infants (52 symptomatic, 54 asymptomatic) of less than 34 weeks of gestation, who fulfilled the eligibility criteria. Babies were considered symptomatic in the presence of vomiting, regurgitation, apnea, de-saturations, unexplained bradycardia and recurrent lung collapses. Radionuclide scintigraphy was conducted at post-conceptional age of 32-34 weeks when they were clinically stable for 72 h. Feeding was avoided for 2 h preceding the study. {sup 99m}Tc sulphur colloid was administered in a dose of 1.85 MBq (0.05 mCi) in 1 ml, followed by milk (full feed) through an orogastric tube, prior to imaging under a gamma camera. Reflux was graded as low or high, and reflux episodes during the study were counted. The incidence of GER in the symptomatic group was 71.2% and in asymptomatic babies 61.1% (p=0.275). High-grade reflux was more common (71.4%) than low-grade (28.6%) in both groups (p=0.449). Mean number of reflux episodes in 20 min was 4.4{+-}2.4 in symptomatic babies and 4.9 {+-}2.2 in asymptomatic babies (p=0.321). Babies with positive scintigraphy were similar in birth weight, gestation, time to achieve full feeds, weight and age at discharge to those with negative scintigraphy. GER is common in pre-term infants of less than 34 weeks gestation. The incidence of positive scintigraphy and grade of reflux is not significantly different in symptomatic vs. asymptomatic babies. Though radionuclide scintigraphy is a simple, quick and non-invasive investigation in

  5. Analysis of diffuse gallium lung uptake

    International Nuclear Information System (INIS)

    Harada, Masahumi; Sui, Osamu; Mukaijo, Toshihumi; Tokuyama, Noritami; Tanouchi, Miki; Kitsukawa, Kaoru

    1989-01-01

    Diffuse lung uptake of Ga-67 was observed on scintigrams in 56 patients. It was considered attributable to drugs in 21 patients. Only 7 patients complained of fever, cough, and dyspnea, 5 of whom spontaneously recovered without any treatment. This seemed to reflect clinically reversible cases, as well as to support the usefulness of Ga-67 scintigraphy in early detection of drug-induced pneumonitis. In one patient that died of acute pneumonitis, only a small amount of cyclophosphamide (3,400 mg) had been administered. Drug dosage seemed to be unrelated to the prognosis of drug-induced pneumonitis. Seventeen patients underwent Ga-67 scintigraphy within one month after the completion of chemotherapy. The most frequently given dosage of cyclophosphamide was 2,000 mg or less. In early detecting drug-induced pneumonitis, the optimum time of Ga-67 scintigraphy was considered to be the first one month after completion of chemotherapy. (Namekawa, K)

  6. Salivary scintigraphy

    International Nuclear Information System (INIS)

    Sabri, P.J.

    1988-01-01

    Salivary gland scintigraphy with technetium 99m ( 99m Tc) in the form pertechnetate ion is a relatively simple procedure, which can provide a unique and sensitive means for investigating salivary gland physiologic function and its derangements. However, salivary scintigraphy is poorly suited for the detection and characterization of masses in and around the salivary glands. Computed tomography (CT) has, therefore, largely supplanted scintigraphy for the evaluation of masses and is the method of choice because it can provide exquisite anatomic detail. Consequently, CT is more sensitive for mass detection and can also provide useful information as to whether a mass has arisen from within or from outside of a salivary gland or whether a mass is circumscribed or invasive. It also can disclose the relationship of the mass to the facial nerve and occasionally can provide histologic characterization of such masses as cysts, lipomas, and masseter muscle hypertrophy

  7. The value of ventilation scintigraphy after single lung transplantation

    NARCIS (Netherlands)

    Ouwens, JP; van der Bij, W; van der Mark, TW; Piers, DA; Koeter, GH

    Background: A decrease in forced expiratory volume in 1 second (FEV1) as a diagnostic criterion for bronchiolitis obliterans syndrome (BOS) after single lung transplantation may be influenced significantly by the presence of the native lung. To quantify and to discriminate between the relative

  8. Diagnostic value of liver scintigraphy in fulminant hepatitis and severe acute hepatitis

    International Nuclear Information System (INIS)

    Shiomi, Susumu; Ikeoka, Naoko; Minowa, Takami; Kuroki, Tetsuo; Harihara, Shigeyoshi; Yamamoto, Sukeo; Ochi, Hironobu; Monna, Takeyuki

    1985-01-01

    Liver scintigraphy was performed in 12 cases with fulminant hepatitis, in 8 cases with severe acute hepatitis and in 44 cases with acute hepatitis. Scintiphotoes of severe hepatitis showed reduction of liver size, marked visualization of the bone marrow and the spleen, so this pattern was useful to differentiate from acute hepatitis. Relative size of the liver calculated by A.L.I. (anterior liver index) showed significant reduction in severe hepatitis compared with that of acute hepatitis. Three of five patients with died of severe hepatitis showed high uptake in the lung and ribs, but none of fifteen patients with severe hepatitis who recovered showed the abnormal accumulation in the lung and in the ribs. (author)

  9. Quantum Chemical and Physicochemical Studies of Oximes (Prophylactics against and Reactivators of Phosphorylated AChE).

    Science.gov (United States)

    1984-10-25

    crystal structure of nicotinic acid ,. and we used the ether bridge from the crystal structure of dimethyl ether. We are investigating various rotamers...observations were made: - The titration curve (after the subtraction of the blank curve) shows only one titrable group, i.e. the oxime moiety. - The...subtraction of the blank curve, shows two titrable groups, i.e. the two oxime moieties. The results are as follows: Temperature Conditions PKa pK2

  10. Efficacy of the Tertiary Oxime Monoisonitrosoacetone (MINA) Against Lethal Sarin Intoxication in the Guinea Pig

    Science.gov (United States)

    2007-10-01

    Sarin 5a. CONTRACT NUMBER Intoxication in the Guinea Pig 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Koplovitz, I and...efficacy of MINA as a treatment for lethal sarin (GB) intoxication in guinea pigs . Male animals were challenged subcutaneously (s.c.) with 2 LD50s...oximes that are readily able to enter the brain. 15. SUBJECT TERMS oximes, brain, sarin, reactivation, nerve agents, guinea pigs 16. SECURITY

  11. Lung perfusion and ventilation scintigraphy in pre- and postoperative diagnostics; Lungenperfusions- und Ventilationsszintigraphie in der prae- und postoperativen Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Sandrock, D.; Munz, D.L. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Charite, Medizinische Fakultaet der Humboldt-Univ. zu Berlin (Germany)

    1998-03-01

    Lung perfusion (Tc-99m labeled albumin particles) and ventilation (Xe-133 gas) are used prior to thoracic surgery in order to evaluate changes in perfusion and ventilation due to the underlying diseases. Furthermore, perfusion scintigraphy allows combined with spirometry the prediction of the postinterventional vital capacity and the forced expiratory volume in 1 s. The correlation coefficient for this procedure compared with values measured postoperatively are in the range of 0.8. The method allows the assessment of operability in terms of postinterventional function. (orig.) [Deutsch] Die Lungenperfusions- (mit Tc-99m-markierten Albuminpartikeln) und die Ventilationsszintigraphie (mit Xe-133 als Gas) werden vor thoraxchirugrischen Eingriffen zur Beurteilung der durch die Grund- oder weitere Erkrankungen bedingte Einschraenkungen von Perfusion und Belueftung eingesetzt. Die Perfusionsszintigraphie erlaubt in Kombination mit der Spirometrie ausserdem die Vorausberechnung der postoperativ zu erwartenden Vitalkapazitaet und des forcierten exspiratorischen Erstsekundenvolumens. Im Vergleich mit den postoperativ gemessenen Volumina liegen die Korrelationskoeffizienten um 0,8. Die Methode ermoeglicht daher eine Beurteilung der Operabilitaet bezueglich der postoperativen Lungenfunktion. (orig.)

  12. The effect of aging and smoking on N-isopropyl-p-[123I]iodoamphetamine (123I-IMP) accumulation in the human lung

    International Nuclear Information System (INIS)

    Hara, Masafumi; Tomiguchi, Seiji; Kojima, Akihiro; Nakashima, Rumi; Ooyama, Youichi; Takahashi, Mutsumasa; Matsumoto, Masanori.

    1994-01-01

    123 I-IMP clearance on dynamic lung scintigraphy was studied by two exponential compartments analysis in order to evaluate the effects of aging and smoking on the pulmonary function. Twenty-four patients (14 smokers and 10 non-smokers), referred for 123 I-IMP brain perfusion study, underwent lung dynamic scintigraphy for 42 min immediately after 123 I-IMP injection. In the non-smoking group 123 I-IMP lung clearance was delayed with aging. A significant correlation was found between aging and clearance rate in the lung. There was also a significant difference in the clearance rates between smoker and non-smoker groups. These findings suggest that smoking and aging affect the pulmonary function. (author)

  13. Usefulness of hybrid SPECT/CT for the {sup 99m}Tc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Bruni, Chiara; Padovano, Federico; Travascio, Laura; Schillaci, Orazio; Simonetti, Giovanni [University of Rome Tor Vergata, Rome (Italy). Dept. of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiotherapy]. E-mail: chiarabruni79@hotmail.com

    2008-12-15

    Cranial osteomyelitis is a potentially fatal lesion. White blood cell scanning (WBC) with {sup 99m}Tc-hexamethylpropylene amine oxime (HMPAO) has proven highly sensitive and specific in the diagnosis and follow-up of patients with suspected osteomyelitis. In this report we show the usefulness of SPECT and transmission CT performed simultaneously using a hybrid imaging device for the functional anatomic mapping of soft tissue and cranial bone infections. {sup 99m}Tc-HMPAO-labeled leukocytes scintigraphy was performed on an elderly diabetic man with an intracranial mass lesion and with suspected temporal bone infection. Planar scans were acquired 30 min, 4 h, and 24 h after injection. SPECT/CT was obtained 6 h after tracer injection, using a dual-head camera coupled with a low-power X-ray tube. The scintigraphic results were matched with the results of surgery and of clinical follow-up. The planar images alone were true-positives for abscess in this patient. SPECT/CT improves the accuracy of {sup 99m}Tc- HMPAO scintigraphy especially in discriminating between soft-tissue and bone involvement. In fact, SPECT/CT also showed temporal bone osteomyelitis. This result indicates that SPECT/CT performed using a hybrid device can improve imaging with {sup 99m}Tc-HMPAO-labeled leukocytes in patients with suspected osteomyelitis by providing accurate anatomic localization and precise definition of the extent of infection. (author)

  14. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Nishimura, Tsunehiko; Kumita, Shin-ichirou; Hayashida, Kohei; Uehara, Toshiisa; Shimonagata, Tsuyoshi; Ohno, Akira

    1991-01-01

    Fifteen cases with primary pulmonary hypertension (PPH) were classified into two groups by using the perfusion lung scan pattern. Eight cases had multiple, small, ill-defined defects (mottled pattern), and remaining seven cases had no mottled pattern. These two groups were compared with mean pulmonary arterial pressure (mean PAP), right ventricular ejection fraction (RVEF), blood gas at room air (PaO 2 ), and alveolar-arterial O 2 difference (A-aDo 2 ). The cases with mottled pattern showed a significant increase in mean PAP. There were no significant differences in RVEF, PaO 2 , and A-aDo 2 , between the groups. The survival rate of the patients with mottled pattern was significantly lower than that without mottled pattern (p<0.05). We concluded that perfusion lung scan is very useful for evaluation of the prognosis in primary pulmonary hypertension. (author)

  15. Should the pulmonary scintigraphy of pre-surgery examination of bronchial carcinomas be made at rest or under effort?

    International Nuclear Information System (INIS)

    David, N.; Olivier, P.; Arsena, T.; Quiri, N.; Hassan, N.; Haouzi, P.; Borelly, J.; Marie, P.Y.; Karcher, G.; Bertrand, A.

    1997-01-01

    One of the key elements in deciding whether a patient, bearing a bronchial carcinoma, should be subject to a surgery is the predicted value of the post-surgery maximal exhaled volume per second (MEVS), usually determined by means of an at-rest pulmonary perfusion scintigraphy. At the same time, this parameter remains rather badly correlated to mortality and peri-surgical morbidity. The goal of this study was to determine whether under-effort pulmonary perfusion scintigraphy, i.e. in peri-surgical conditions gives different results in this case. Twenty patients bearing bronchial carcinoma have benefited by a pulmonary scintigraphy, successively, in the end of an exercise on ergo-metric bicycle and at rest. Two mCi of Tc-labelled macro-aggregate albumin were injected after effort, then 10 mCi one hour later, at rest. The homo-lateral lung perfusion to tumor, expresses in % of total pulmonary perfusion (% TP), was reduced at rest (-8 ± 6%) and at effort (-10 ± 8%), in comparison with the normal values. On the analysis of ensemble of population (43 ± 7% vs 41 ± 9%, NS) the % TP did not changed significantly between the at-rest and under-effort acquisitions. At the same time, 4 patients presented important variation, amounting up to 20% of total pulmonary perfusion: the % TP increased in 2 cases and decreased in the other 2 cases. In conclusion, in the patients bearing bronchial carcinoma, the relative perfusion of tumoral lung varies under effort in a non-negligible number of cases (4/20). Additional studies are necessary to establish the value of under-effort pulmonary scintigraphy, in the evaluation of the post-surgery respiratory functional capacity

  16. 99mTc-RBC subtraction scintigraphy

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru

    1994-01-01

    Sequential abdominal scintigrams with 99m Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author)

  17. Study of regional lung ventilation and perfusion by xenon 133

    International Nuclear Information System (INIS)

    Lombard, Yves.

    1976-01-01

    The present work consists of a regional lung exploration after injection of xenon 133, dissolved in physiological serum, followed a few minutes later by that of 99m Tc-labelled serumalbumin microspheres. The aim is three fold: first of all to study perfusion and ventilation by xenon 133, next to compare the results obtained after xenon 133 and 99 m Tc-labelled microsphere injection, lastly to establish the value of the technique and its routine application. This examination has not solved all problems of lung exploration by xenon 133. For example we deliberately kept to intraveinous injection of the gas dissolved in physiological serum, leaving aside the breathing test. Xenon 133 scintigraphy in our opinion will not tend to replace 99m Tc-labelled microsphere scintigraphy, which has irreplaceable morphological qualities, but will serve as an excellent complement. The basic advantage of xenon 133 is the regional ventilation estimate it provides allowing any anomaly of the lung parenchyma to be located immediately or conversely the functional value of the healthy lung to be established with a view to a surgical removal of a diseased zone [fr

  18. t-3-Benzyl-r-2,c-6-diphenylpiperidin-4-one oxime

    Directory of Open Access Journals (Sweden)

    R. Arulraj

    2016-12-01

    Full Text Available In the title compound, C24H24N2O [systematic name: (E-3-benzyl-2,6-diphenylpiperidin-4-one oxime], the piperidine ring adopts a slightly distorted chair conformation and the phenyl rings and the benzyl group substituents are attached equatorially. The oxime group makes a dihedral angle of 42.88 (12° with the piperidine ring. The dihedral angle between the phenyl rings is 71.96 (8°. The benzyl ring makes dihedral angles of 63.01 (8 and 59.35 (8° with the two phenyl rings. In the crystal, molecules are linked by O—H...N hydrogen bonds, forming C(7 chains along the c axis. The chains are linked by C—H...π interactions, forming slabs lying parallel to the bc plane.

  19. Binding of Reactive Organophosphate by Oximes via Hydrogen Bond

    Indian Academy of Sciences (India)

    Giuseppe Trusso

    Stoichiometries of the complexes were investigated by the Job plot method using spectrophotometric measurements. The samples were prepared by mixing equimolecular stock solutions (3.7 x 10. -3. M) in dry CH3CN of the appropriate oxime and DMMP to cover the whole range of molar fractions keeping constant the total ...

  20. Adrenal scintigraphy using 131I-Adosterol

    International Nuclear Information System (INIS)

    Fukunaga, Masao; Dokoh, Shigeharu; Yamamoto, Itsuo; Morita, Rikushi; Torizuka, Kanji

    1977-01-01

    131 I-Adosterol (6β-iodomethyl-19-norcholest-5(10)-3β-ol) was administered to evaluate adrenal grand in 20 patients including 9 patients with primary aldosteronism, 5 with Cushing's syndrome, one with pheochromocytoma, one with retroperitoneal tumor, 3 with essential hypertension and one with obesity. Standard scintigraphies were performed at 3rd day and again 6th day after administration of 131 I-adosterol (1-1.5 mCi). Suppression scintigraphies were obtained while the patients were taking dexamethasone 2 to 3 mg daily from 3 days prior to injection of the tracer until adrenal imaging. In the cases with essential hypertension and obesity, both adrenal glands were delineated equally by standard scintigraphy, and in one patient, undergone suppression scintigraphy, the uptake of 131 I-adosterol by both glands were completely inhibited by dexamethasone administration. In primary aldosteronism, six of the 9 patients demonstrated the increased radioactivity in one side, and were diagnosed as aldosteronoma. In 3 cases, failed to show the lesions on standard scintigraphy, the lesions could be detected by suppression scintigraphy, and aldosteronomas measuring 1 x 1 x 0.7, 2 x 2 x 1 and 1.7 x 1.5 x 0.8 cm were confirmed by operation. In Cushing's syndrome, standard scintigraphy could easily distinguish between adenoma (one case) and bilateral hyperplasia (4 cases). Adrenal scintigraphy was also a useful method in order to assess the effect of pituitary irradiation therapy in the case of hyperplasia. In pheochromocytoma and retroperitoneal tumor, the side of the lesion was identified by the absence of a functioning gland. Suppression scintigraphy was particularly useful in detecting the localization of the small tumor in primary aldosteronism. (auth.)

  1. Clinical evaluation of tumor scintigraphy with /sup 57/Co-bleomycin

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, K; Kawahira, K; Nakayama, C; Kamoi, I; Matsuura, K [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1975-06-01

    Of 84 patients to whom tumor scintigraphy with /sup 57/Co-bleomycin was performed, 76 patients were clinically evaluated. 47 per cent of the patients with malignant tumor were positive, and 3 of 10 patients with benign diseases showed positive picture. The positive rate was examined according to diseases, and 65.4% was found to be positive in primary lung cancer and 50% in malignant lymphoma. As positive rate was relatively low and count efficiency was also low in spite of the accumulation in the lesion in the scintigraphy with /sup 57/Co-bleomycin, the examination took long time and there was a difficulty in the management of urine excretions. It was therefore, inferior to that with /sup 67/Ga-citrate which was widely utilized at present. However, /sup 57/Co-bleomycin distributed in the bones in a small amount and the radioactivity level in the blood was low, so that it was considered to be effective to the diagnosis of tumors localized in the regions that were not above the bones. This point should be investigated as a future program.

  2. The safety of dipyridamole in patients undergoing myocardial perfusion scintigraphy prior to lung volume reduction surgery

    International Nuclear Information System (INIS)

    Roman, M.R.; Angelides, S.; Parker, M.K.; Silva, I. da; Freeman, A.P.

    2001-01-01

    Patients with end-stage chronic obstructive pulmonary disease (COPD) undergoing lung volume reduction surgery (LVRS) are at high risk of peri-operative cardiac complications, and myocardial perfusion scintigraphy (MPS) is commonly used for risk stratification. This study prospectively assessed the safety of dipyridamole in these patients and compared the incidence of side-effects (particularly dyspnoea) with that in patients undergoing dipyridamole MPS prior to elective non-cardiothoracic surgery. Fifty patients were enrolled: 25 in the LVRS cohort (13 males, 12 females), with a mean age of 65 years and a mean FEV 1 of 0.79 l, and 25 (with no history of asthma or COPD) in the control cohort (14 males, 11 females), with a mean age of 66 years. Fourteen patients (56%) in each group developed side-effects. Dyspnoea was reported by five patients (20%) in the LVRS and two patients (8%) in the control cohort (P=NS). One patient in each cohort developed severe hypotension and bradycardia. Eight (32%) other patients developed minor side-effects in the LVRS cohort compared with 11 (44%) in the control group. All side-effects responded promptly to intravenous aminophylline. In summary, there was a statistically non-significant increase in the incidence of dyspnoea in patients with end-stage COPD and all side-effects responded to aminophylline. Thus, dipyridamole can be used safely in these patients. (orig.)

  3. Theoretical NMR and conformational analysis of solvated oximes for organophosphates-inhibited acetylcholinesterase reactivation

    Science.gov (United States)

    da Silva, Jorge Alberto Valle; Modesto-Costa, Lucas; de Koning, Martijn C.; Borges, Itamar; França, Tanos Celmar Costa

    2018-01-01

    In this work, quaternary and non-quaternary oximes designed to bind at the peripheral site of acetylcholinesterase previously inhibited by organophosphates were investigated theoretically. Some of those oximes have a large number of degrees of freedom, thus requiring an accurate method to obtain molecular geometries. For this reason, the density functional theory (DFT) was employed to refine their molecular geometries after conformational analysis and to compare their 1H and 13C nuclear magnetic resonance (NMR) theoretical signals in gas-phase and in solvent. A good agreement with experimental data was achieved and the same theoretical approach was employed to obtain the geometries in water environment for further studies.

  4. Spectrophotometric determination of pKa's of 1-hydroxybenzotriazole and oxime derivatives in 95% acetonitrile-water

    International Nuclear Information System (INIS)

    Fathallah, M.F.; Khattab, S.N.

    2011-01-01

    1-hydroxybenzotriazole derivatives are used with carbodiimide as additives to generate active esters during peptide bond formation. They are also used as additives during the peptide bond formation. Dissociation constants of the 1-hydroxybenzotriazole (HOBt) and its derivatives, 1-hydroxy-6-chloro benzotriazole, 1-hydroxy-6-trifluoro methylbenzotriazole, 1-hydroxy-6-nitrobenzo-triazole were determined spectrophotometrically in 95% acetonitrile-water. In addition, 7-aza-1-hydroxybenzotriazole (7-HOAt) and 4-aza-1-hydroxybenzotriazole (4-HOAt) were also studied. Recently, oxyma was reported as a good replacement for the benzotriazole derivatives. As alcoholic components of active esters, the oximes seem to be good leaving groups. Therefore it was expected, that the strongly acidic and nucleophilic oximes, which possess electron-withdrawing groups in the molecule, are suitable as additives during the peptide bond formation. The dissociation constant of some oximes, such as diethyl 2-(hydroxyimino)malonate, ethyl 2-cyano-2-(hydroxyimino)acetate (oxyma), hydroxycarbonimidoyl dicyanide and N-hydroxypicolinimidoyl cyanide in 95% acetonitrile-water are reported. (author)

  5. Serial perfusion in native lungs in patients with idiopathic pulmonary fibrosis and other interstitial lung diseases after single lung transplantation.

    Science.gov (United States)

    Sokai, Akihiko; Handa, Tomohiro; Chen, Fengshi; Tanizawa, Kiminobu; Aoyama, Akihiro; Kubo, Takeshi; Ikezoe, Kohei; Nakatsuka, Yoshinari; Oguma, Tsuyoshi; Hirai, Toyohiro; Nagai, Sonoko; Chin, Kazuo; Date, Hiroshi; Mishima, Michiaki

    2016-04-01

    Lung perfusions after single lung transplantation (SLT) have not been fully clarified in patients with interstitial lung disease (ILD). The present study aimed to investigate temporal changes in native lung perfusion and their associated clinical factors in patients with ILD who have undergone SLT. Eleven patients were enrolled. Perfusion scintigraphy was serially performed up to 12 months after SLT. Correlations between the post-operative perfusion ratio in the native lung and clinical parameters, including pre-operative perfusion ratio and computed tomography (CT) volumetric parameters, were evaluated. On average, the perfusion ratio of the native lung was maintained at approximately 30% until 12 months after SLT. However, the ratio declined more significantly in idiopathic pulmonary fibrosis (IPF) than in other ILDs (p = 0.014). The perfusion ratio before SLT was significantly correlated with that at three months after SLT (ρ = 0.64, p = 0.048). The temporal change of the perfusion ratio in the native lung did not correlate with those of the CT parameters. The pre-operative perfusion ratio may predict the post-operative perfusion ratio of the native lung shortly after SLT in ILD. Perfusion of the native lung may decline faster in IPF compared with other ILDs. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Design and Biological Evaluation of Antifouling Dihydrostilbene Oxime Hybrids.

    Science.gov (United States)

    Moodie, Lindon W K; Cervin, Gunnar; Trepos, Rozenn; Labriere, Christophe; Hellio, Claire; Pavia, Henrik; Svenson, Johan

    2018-04-01

    By combining the recently reported repelling natural dihydrostilbene scaffold with an oxime moiety found in many marine antifoulants, a library of nine antifouling hybrid compounds was developed and biologically evaluated. The prepared compounds were shown to display a low antifouling effect against marine bacteria but a high potency against the attachment and growth of microalgae down to MIC values of 0.01 μg/mL for the most potent hybrid. The mode of action can be characterized as repelling via a reversible non-toxic biostatic mechanism. Barnacle cyprid larval settlement was also inhibited at low μg/mL concentrations with low levels or no toxicity observed. Several of the prepared compounds performed better than many reported antifouling marine natural products. While several of the prepared compounds are highly active as antifoulants, no apparent synergy is observed by incorporating the oxime functionality into the dihydrostilbene scaffold. This observation is discussed in light of recently reported literature data on related marine natural antifoulants and antifouling hybrids as a potentially general strategy for generation of improved antifoulants.

  7. Scintigraphic evaluation of brain death with 99mTc-d,l-hexamethyl-propyleneamine oxime (HMPAO)

    International Nuclear Information System (INIS)

    Takehara, Yasuo; Isoda, Haruo; Sakai, Tsuneo; Tanaka, Tokutaro; Sato, Haruhiko; Yamamoto, Takamichi; Takahashi, Motoichiro; Kaneko, Masao.

    1989-01-01

    Lately, the criteria of brain death is being discussed. Cerebral scintigram, especially scintigraphic evaluation of brain death by dynamic study, has been previously reported. Cerebral imaging using radiolabeled amines such as 123 I-IMP N-isopropyl-p-iodoamphetamin (IMP) or 99m Tc d, l-hexamethyl-propyleneamine oxime (HMPAO) offers a significant information of brain death by the finding of 'non visualized brain'. However, the dynamic scintigram acquired during the bolus injection of 99m Tc-HMPAO provides an additional information of brain death by classical 'hot nose sign'. 99m Tc-HMPAO is able to be administered relatively in a large amount of dose. This cerebral perfusion tracer is lipophilic and remains in the central nervous system, which characterize its role as a reliable indicator of cerebral blood flow. As a result, this compound became suitable for the non-invasive study of brain circulation when the diagnosis of brain death is uncertain. We report a case of brain death in which diagnosis was made by the classical 'hot nose sign' in dynamic scintigraphy performed when 99 mTc-HMPAO was injected as well as the SPECT which showed a lack of cerebral visualization at the equilibrium state. As far as we are informed, this additional procedure used in the diagnosis of brain death has not reported before. The importance of performing a dynamic scintigram at the administration of 99m Tc-HMPAO is also discussed in this report. (author)

  8. Radionuclide scintigraphy in the evaluation of gastroesophageal reflux in symptomatic and asymptomatic pre-term infants

    International Nuclear Information System (INIS)

    Morigeri, C.; Mukhopadhyay, K.; Narang, A.; Bhattacharya, A.; Mittal, B.R.

    2008-01-01

    Gastroesophageal reflux (GER) is very common in pre-term infants. The diagnosis based on symptoms is always questionable. The incidence of GER in symptomatic babies varies from 22% to 85%, but literature regarding the incidence of reflux in asymptomatic pre-term infants is lacking. We used radionuclide scintigraphy to evaluate the incidence of GER in symptomatic as well as asymptomatic pre-term neonates and to assess whether symptoms have any relation with positive scintigraphy. We studied 106 pre-term infants (52 symptomatic, 54 asymptomatic) of less than 34 weeks of gestation, who fulfilled the eligibility criteria. Babies were considered symptomatic in the presence of vomiting, regurgitation, apnea, de-saturations, unexplained bradycardia and recurrent lung collapses. Radionuclide scintigraphy was conducted at post-conceptional age of 32-34 weeks when they were clinically stable for 72 h. Feeding was avoided for 2 h preceding the study. 99m Tc sulphur colloid was administered in a dose of 1.85 MBq (0.05 mCi) in 1 ml, followed by milk (full feed) through an orogastric tube, prior to imaging under a gamma camera. Reflux was graded as low or high, and reflux episodes during the study were counted. The incidence of GER in the symptomatic group was 71.2% and in asymptomatic babies 61.1% (p=0.275). High-grade reflux was more common (71.4%) than low-grade (28.6%) in both groups (p=0.449). Mean number of reflux episodes in 20 min was 4.4±2.4 in symptomatic babies and 4.9 ±2.2 in asymptomatic babies (p=0.321). Babies with positive scintigraphy were similar in birth weight, gestation, time to achieve full feeds, weight and age at discharge to those with negative scintigraphy. GER is common in pre-term infants of less than 34 weeks gestation. The incidence of positive scintigraphy and grade of reflux is not significantly different in symptomatic vs. asymptomatic babies. Though radionuclide scintigraphy is a simple, quick and non-invasive investigation in suspected cases

  9. Scintigraphy of spinal disorders in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Mandell, G.A. (Dept. of Medical Imaging, Alfred I. duPont Inst., Wilmington, DE (United States)); Harcke, H.T. (Dept. of Medical Imaging, Alfred I. duPont Inst., Wilmington, DE (United States))

    1993-08-01

    Bone scintigraphy in adolescents is useful in helping to differentiate between developmental (atypical lumbar Scheuermann disease), infectious (discitis, osteomyelitis), neoplastic (osteoid osteoma, osteoblastoma), and traumatic (occult fractures, spondylolysis, pseudoarthrosis) disease of the spine. Double-phase (blood pool, delayed images) scintigraphy can characterize the pattern (i.e., linear in fracture, ovoid in nidus of osteoid osteoma). Single-photon emission computed tomography (SPECT) can be helpful in detecting the subtle presence of stress reaction (spondylolyses) not noted on routine planar scintigraphy and radiography. Bone scintigraphy is most beneficial when correlated with other imaging modalities in refining the diagnosis of spinal diseases. (orig.)

  10. Scintigraphy of spinal disorders in adolescents

    International Nuclear Information System (INIS)

    Mandell, G.A.; Harcke, H.T.

    1993-01-01

    Bone scintigraphy in adolescents is useful in helping to differentiate between developmental (atypical lumbar Scheuermann disease), infectious (discitis, osteomyelitis), neoplastic (osteoid osteoma, osteoblastoma), and traumatic (occult fractures, spondylolysis, pseudoarthrosis) disease of the spine. Double-phase (blood pool, delayed images) scintigraphy can characterize the pattern (i.e., linear in fracture, ovoid in nidus of osteoid osteoma). Single-photon emission computed tomography (SPECT) can be helpful in detecting the subtle presence of stress reaction (spondylolyses) not noted on routine planar scintigraphy and radiography. Bone scintigraphy is most beneficial when correlated with other imaging modalities in refining the diagnosis of spinal diseases. (orig.)

  11. Do preliminary chest X-ray findings define the optimum role of pulmonary scintigraphy in suspected pulmonary embolism?

    International Nuclear Information System (INIS)

    Forbes, Kirsten P.N.; Reid, John H.; Murchison, John T.

    2001-01-01

    AIM: To investigate if preliminary chest radiograph (CXR) findings can define the optimum role of lung scintigraphy in subjects investigated for pulmonary embolism (PE). MATERIALS AND METHODS: The CXR and scintigraphy findings from 613 consecutive subjects investigated for suspected PE were retrieved from a radiological database. Of 393 patients with abnormal CXRs, a subgroup of 238 was examined and individual radiographic abnormalities were characterized. CXR findings were related to the scintigraphy result. RESULTS: Scintigraphy was normal in 286 subjects (47%), non-diagnostic in 207 (34%) and high probability for PE in 120 (20%). In 393 subjects (64%) the preliminary CXR was abnormal and 188 (48%) of scintigrams in this group were non-diagnostic. Individual radiographic abnormalities were not associated with significantly different scintigraphic outcomes. If the preliminary CXR was normal (36%), the proportion of non-diagnostic scintigrams decreased to 9% (19 of 220 subjects) (P < 0.05). CONCLUSION: In subjects investigated for PE, an abnormal CXR increases the prevalence of non-diagnostic scintigrams. A normal pre-test CXR is more often associated with a definitive (normal or high probability) scintigram result. The chest radiograph may be useful in deciding the optimum sequence of investigations. Forbes, K.P.N., Reid, J.H., Murchison, J.T. (2001)

  12. Glycoconjugate Oxime Formation Catalyzed at Neutral pH: Mechanistic Insights and Applications of 1,4-Diaminobenzene as a Superior Catalyst for Complex Carbohydrates.

    Science.gov (United States)

    Østergaard, Mads; Christensen, Niels Johan; Hjuler, Christian T; Jensen, Knud J; Thygesen, Mikkel B

    2018-04-18

    The reaction of unprotected carbohydrates with aminooxy reagents to provide oximes is a key method for the construction of glycoconjugates. Aniline and derivatives serve as organocatalysts for the formation of oximes from simple aldehydes, and we have previously reported that aniline also catalyzes the formation of oximes from the more complex aldehydes, carbohydrates. Here, we present a comprehensive study of the effect of aniline analogues on the formation of carbohydrate oximes and related glycoconjugates depending on organocatalyst structure, pH, nucleophile, and carbohydrate, covering more than 150 different reaction conditions. The observed superiority of the 1,4-diaminobenzene (PDA) catalyst at neutral pH is rationalized by NMR analyses and DFT studies of reaction intermediates. Carbohydrate oxime formation at pH 7 is demonstrated by the formation of a bioactive glycoconjugate from a labile, decorated octasaccharide originating from exopolysaccharides of the soil bacterium Mesorhizobium loti. This study of glycoconjugate formation includes the first direct comparison of aniline-catalyzed reaction rates and equilibrium constants for different classes of nucleophiles, including primary oxyamines, secondary N-alkyl oxyamines, as well as aryl and arylsulfonyl hydrazides. We identified 1,4-diaminobenzene as a superior catalyst for the construction of oxime-linked glycoconjugates under mild conditions.

  13. Reaction of Non-Symmetric Schiff Base Metallo-Ligand Complexes Possessing an Oxime Function with Ln Ions

    Directory of Open Access Journals (Sweden)

    Jean-Pierre Costes

    2018-03-01

    Full Text Available The preparation of non-symmetric Schiff base ligands possessing one oxime function that is associated to a second function such as pyrrole or phenol function is first described. These ligands, which possess inner N4 or N3O coordination sites, allow formation of cationic or neutral non-symmetric CuII or NiII metallo-ligand complexes under their mono- or di-deprotonated forms. In presence of Lanthanide ions the neutral complexes do not coordinate to the LnIII ions, the oxygen atom of the oxime function being only hydrogen-bonded to a water molecule that is linked to the LnIII ion. This surprising behavior allows for the isolation of LnIII ions by non-interacting metal complexes. Reaction of cationic NiII complexes possessing a protonated oxime function with LnIII ions leads to the formation of original and dianionic (Gd(NO352− entities that are well separated from each other. This work highlights the preparation of well isolated mononuclear LnIII entities into a matrix of diamagnetic metal complexes. These new complexes complete our previous work dealing with the complexing ability of the oxime function toward Lanthanide ions. It could open the way to the synthesis of new entities with interesting properties, such as single-ion magnets for example.

  14. Study on the deposition patterns of aerosol inhalation scintigraphy, 1; Comparison of the deposition patterns of aerosol inhalation scintigraphy with lung function tests in pulmonary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Hiroyuki [Nara Medical Univ., Kashihara (Japan)

    1989-06-01

    The deposition patterns of aerosol inhalation scintigraphies and lung function tests were studied in 102 cases; 64 cases of obstructive pulmonary diseases (19 pulmonary emphysema, 27 diffuse panbronchiolitis, 18 chronic bronchitis) and 38 restrictive pulmonary disease (15 idiopathic interstitial pneumonia, 16 pulmonary asbestosis, 7 interstitial pneumonia due to collagen vascular disease). The deposition patterns were classified into 5 patterns (Type A:normal homogenous distribution; Type B: mildly unhomogenous distribution; Type C: severely unhomogenous distribution mingled with hot spots; Type D: non-hilar hot spots; and Type E: hilar hot spots). The deposition patterns of restrictive pulmonary diseases were markedly abnormal as well as obstructive pulmonary diseases. The deposition patterns showed mainly Types C, D and E in obstructive pulmonary diseases, Type B in restrictive pulmonary diseases. The deposition patterns showed mainly Type E in pulmonary emphysema, Types C and D in diffuse panbronchiolitis, Types A, B and C in chronic bronchitis, Type B in idiopathic interstitial pneumonia interstitial pneumonia due to collagen vascular disease, Types B and C in pulmonary asbestosis. The deposition patterns correlated well with %FEV{sub 1.0} which was a good indicator of the severity of obstructive pulmonary diseases and restrictive pulmonary diseases. Furthermore, the mean %FEV{sub 1.0} in obstructive pulmonary diseases was nearly equal to the mean %FEV{sub 1.0} in restrictive pulmonary diseases in each type of the deposition patterns. (J.P.N.).

  15. Synthesis and antimicrobial activities of new oxime carbamates of 3 ...

    Indian Academy of Sciences (India)

    Abstract. S-alkylation of 3-aryl-2-thioquinazolin-4(3H)-one (1) with chloroacetone gave 2-(propanonyl thio)-3-arylquinazol-4(3H)ones (2). Further, the treatment of compound (2) with hydroxylamine hydrochloride gave the corresponding oximes (3) which on reaction with phenyl isocyanate in THF yielded corresponding.

  16. Diprotonated hydrazones and oximes as reactive intermediates in electrochemical reductions

    Czech Academy of Sciences Publication Activity Database

    Baymak, M. S.; Celik, H.; Ludvík, Jiří; Lund, H.; Zuman, P.

    2004-01-01

    Roč. 45, č. 26 (2004), s. 5113-5115 ISSN 0040-4039 R&D Projects: GA ČR GA203/01/1093; GA AV ČR IAA4040304 Institutional research plan: CEZ:AV0Z4040901 Keywords : hydrazones * oximes * diprotonation Subject RIV: CG - Electrochemistry Impact factor: 2.484, year: 2004

  17. Selective Tandem Synthesis of Oximes from Benzylic Alcohols Catalyzed with 2, 3-Dichloro-5, 6-dicyanobenzoquinone

    Energy Technology Data Exchange (ETDEWEB)

    Aghapour, Ghasem; Mohamadian, Samaneh [Damghan University, Damghan (Iran, Islamic Republic of)

    2012-04-15

    In spite of many reports in the literature concerning with oxidation of benzylic alcohols to carbonyl compounds with 2,3-dichloro-5,6-dicyanobenzoquinone (DDQ) in stoichiometric amounts or even more, we surprisingly found that benzylic alcohols are directly oxidized to oximes using a catalytic amount of DDQ in the presence of hydroxylamine hydrochloride under solvent-free conditions. The present tandem catalytic method can be efficiently used for preparation of oximes in the presence of some other functional groups with excellent chemoselectivity

  18. Lacrimal scintigraphy in the diagnosis of epiphora

    International Nuclear Information System (INIS)

    Hanna, I.T.; MacEwen, C.J.; Kennedy, N.

    1992-01-01

    The value of lacrimal scintigraphy in the assessment of nasolacrimal duct obstruction was determined by comparing the results with syringing in 67 patients (83 eyes). As expected, of 28 lacrimal drainage systems which were obstructed on syringing, 23 (82%) had abnormalities of tear drainage on scintigraphy. However, in 55 lacrimal drainage systems that were patent on syringing, 19 (35%) were normal, but in 36 (65%) abnormalities not apparent on syringing were detected on scintigraphy. Thus scintigraphy is a very useful technique in the assessment of nasolacrimal duct obstruction particularly in systems patent on syringing. Since the site of obstruction can be determined, lacrimal scintigraphy can facilitate the planning of the appropriate surgery. (author)

  19. Experimental study of per-rectal portal scintigraphy using 99mTc-EHIDA

    International Nuclear Information System (INIS)

    Tamaki, Satoshi; Shinotsuka, Akira; Takenaka, Hiroki

    1991-01-01

    We discovered that 99m Tc-diethyl iminodiacetic acid ( 99m Tc-EHIDA) commonly used for hepatobiliary scintigraphy could also be administered per-rectally, with adequate absorption and optimal visualization of the portal system. To evaluate its usefulness, we experimented on rabbits using the method. Portal scintigraphy with rectal administration of 99m Tc-EHIDA, 123 I-N-isopropyl-p-iodoamphetamine ( 123 I-IMP) and 99m Tc-red blood cell ( 99m Tc-RBC) were performed in normal rabbits and in extrahepatic portal shunt model rabbits. Images of the liver and thorax were obtained and shunt indices were calculated from the count values of liver and lung or heart. Then the shunt indices were compared with shunt rate derived from direct injection of 99m Tc-macroaglutinated albumin ( 99m Tc-MAA) into inferior mesenteric vein. Correlation between shunt rate of 99m Tc-MAA and shunt indices of 99m Tc-RBC, 123 I-IMP and 99m Tc-EHIDA were 0.64, 0.75 and 0.78, respectively, with 99m Tc-EHIDA having the most favorable results. We concluded that 99m Tc-EHIDA per-rectal portal scintigraphy is a noninvasive, quantitative, inexpensive and simple method for evaluation of portal circulation system. Also, we think that this method would be applicable to human usage from our experience with normal volunteers. (author)

  20. Eco-friendly synthesis, physicochemical studies, biological assay and molecular docking of steroidal oxime-ethers

    Science.gov (United States)

    Alam, Mahboob; Lee, Dong-Ung

    2015-01-01

    The aim of this study was to report the synthesis of biologically active compounds; 7-(2′-aminoethoxyimino)-cholest-5-ene (4), a steroidal oxime-ether and its derivatives (5, 6) via a facile microwave assisted solvent free reaction methodology. This new synthetic, eco-friendly, sustainable protocol resulted in a remarkable improvement in the synthetic efficiency (85-93 % yield) and high purity using basic alumina. The synthesized compounds were screened for their antibacterial against six bacterial strains by disc diffusion method and antioxidant potential by DPPH assay. The binding capabilities of a compound 6 exhibiting good antibacterial potential were assessed on the basis of molecular docking studies and four types of three-dimensional molecular field descriptors. Moreover the structure-antimicrobial activity relationships were studied using some physicochemical and quantum-chemical parameters with GAMESS interface as well as WebMO Job Manager by using the basic level of theory. Hence, this synthetic approach is believed to provide a better scope for the synthesis of steroidal oxime-ether analogues and will be a more practical alternative to the presently existing procedures. Moreover, detailed in silico docking studies suggested the plausible mechanism of steroidal oxime-ethers as effective antimicrobial agents. PMID:27330525

  1. Insights into the mechanism and catalysis of oxime coupling chemistry at physiological pH.

    Science.gov (United States)

    Wang, Shujiang; Gurav, Deepanjali; Oommen, Oommen P; Varghese, Oommen P

    2015-04-07

    The dynamic covalent-coupling reaction involving α-effect nucleophiles has revolutionized bioconjugation approaches, due to its ease and high efficiency. Key to its success is the discovery of aniline as a nucleophilic catalyst, which made this reaction feasible under physiological conditions. Aniline however, is not so effective for keto substrates. Here, we investigate the mechanism of aniline activation in the oxime reaction with aldehyde and keto substrates. We also present carboxylates as activating agents that can promote the oxime reaction with both aldehyde and keto substrates at physiological pH. This rate enhancement circumvents the influence of α-effect by forming H-bonds with the rate-limiting intermediate, which drives the reaction to completion. The combination of aniline and carboxylates had a synergistic effect, resulting in a ∼14-31-fold increase in reaction rate at pD 7.4 with keto substrates. The biocompatibility and efficiency of carboxylate as an activating agent is demonstrated by performing cell-surface oxime labeling at physiological pH using acetate, which showed promising results that were comparable with aniline. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Estimation of 123I-metaiodobenzylguanidine lung uptake in heart and lung diseases. With reference to lung uptake ratio and decrease of lung uptake

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Yazaki, Yoshikazu; Kitabayashi, Hiroshi; Koizumi, Tomonori; Sekiguchi, Morie; Gomi, Tsutomu; Yano, Kesato; Itoh, Atsuko.

    1997-01-01

    123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was performed in 64 patients with heart and lung diseases. Distribution of MIBG in the chest was evaluated by planar images, using counts ratios of the heart to the mediastinum (H/M) and the unilateral lung to the mediastinum (Lu/M). Most of patients with heart diseases showed obvious lung uptake of MIBG. The ratios of H/M were 1.75±0.20 in the group without heart failure and 1.55±0.19 in the group with heart failure. The ratios of Lu/M in the right and left lung were 1.56±0.16 and 1.28±0.16 in the group without heart failure. And those were 1.45±0.16 and 1.19±0.15 in the group with heart failure. But 3 patients complicated with chronic pulmonary emphysema and one patient with interstitial pneumonia due to dermatomyositis showed markedly decreased lung uptake. The ratios of Lu/M in the right and left lung of these patients were 1.20, 1.17; 1.17, 1.13; 1.01, 0.97 and 1.27, 0.94, respectively. These results suggest that the lung uptake of MIBG may reflect the state of pulmonary endothelial cell function in clinical situations, considering that it has been demonstrated that MIBG may be useful as a marker of pulmonary endothelial cell function in the isolated rat lung. (author)

  3. Efficient Conversion of Oximes to the Corresponding Carbonyl Compounds with Tetrabutylammonium Chromate under Aprotic Conditions

    International Nuclear Information System (INIS)

    Pourali, Ali Reza; Goli, Arezou

    2006-01-01

    The solubility in several solvents, mildness, simple work-up and absence of side reactions provide advantages of using TBAC in deoximation reactions. This is an efficient and selective method for homogeneous deoximation of structurally different compounds under the moderately acidic and aprotic conditions in high yields. Regeneration of ketones and aldehydes from their oximes has assumed added importance since the discovery of the Barton reaction in which oximes are produced at non-activated hydrocarbon sites. Also, their synthesis from non-carbonyl compounds, such as by nitrosation of an active methylene group, nitrosation of an α-halo carbonyl compound and condensation of a nitro-alkene with an aldehyde provides a valid alternative pathway to carbonyl compounds. Therefore, there has been a continued interest in the effective regeneration of carbonyl compounds from the corresponding oximes especially under mild conditions. Oxidative and reductive methods have been found to show advantages over the classical hydrolytic methods. Although many oxidizing agents have been used, only a limited number of methods are efficient because of the low solubility of these metallic reagents in most organic solvents

  4. Myocardial scintigraphy with thallium-201

    Energy Technology Data Exchange (ETDEWEB)

    Lichte, H [Zentralkrankenhaus Gauting (Germany, F.R.). Nuklearmedizinische Abt.

    1977-04-01

    Myocardial scintigraphy with /sup 201/thallium is a non-invasive method for detection of myocardial infarction and coronary heart disease. Redistribution-analysis as a sequential-scintigraphy of an exercise-scan permits to distinguish between myocardial scars and coronary vessel disease.

  5. Scintigraphy in equine practice

    International Nuclear Information System (INIS)

    Fulton, I.C.; Anderson, B.

    2002-01-01

    The most common use for nuclear medicine in equine practice is bone imaging using technetium 99m as the radionuclide. This article will describe establishment of a facility to perform equine scintigraphy, the peculiarities associated with nuclear medicine and horses and describe a variety of the pathology we identify using scintigraphy. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  6. Two reduction waves of oximes and imine formation in acidic media

    Czech Academy of Sciences Publication Activity Database

    Celik, H.; Ludvík, Jiří; Zuman, P.

    2006-01-01

    Roč. 51, č. 26 (2006), s. 5845-5852 ISSN 0013-4686 R&D Projects: GA MŠk 1P05ME785 Institutional research plan: CEZ:AV0Z40400503 Keywords : oximes * electroreduction * polarography Subject RIV: CG - Electrochemistry Impact factor: 2.955, year: 2006

  7. Indirubin-3-Oxime Prevents H2O2-Induced Neuronal Apoptosis via Concurrently Inhibiting GSK3β and the ERK Pathway.

    Science.gov (United States)

    Yu, Jie; Zheng, Jiacheng; Lin, Jiajia; Jin, Linlu; Yu, Rui; Mak, Shinghung; Hu, Shengquan; Sun, Hongya; Wu, Xiang; Zhang, Zaijun; Lee, Mingyuen; Tsim, Wahkeung; Su, Wei; Zhou, Wenhua; Cui, Wei; Han, Yifan; Wang, Qinwen

    2017-05-01

    Oxidative stress-induced neuronal apoptosis plays an important role in many neurodegenerative disorders. In this study, we have shown that indirubin-3-oxime, a derivative of indirubin originally designed for leukemia therapy, could prevent hydrogen peroxide (H 2 O 2 )-induced apoptosis in both SH-SY5Y cells and primary cerebellar granule neurons. H 2 O 2 exposure led to the increased activities of glycogen synthase kinase 3β (GSK3β) and extracellular signal-regulated kinase (ERK) in SH-SY5Y cells. Indirubin-3-oxime treatment significantly reversed the altered activity of both the PI3-K/Akt/GSK3β cascade and the ERK pathway induced by H 2 O 2 . In addition, both GSK3β and mitogen-activated protein kinase inhibitors significantly prevented H 2 O 2 -induced neuronal apoptosis. Moreover, specific inhibitors of the phosphoinositide 3-kinase (PI3-K) abolished the neuroprotective effects of indirubin-3-oxime against H 2 O 2 -induced neuronal apoptosis. These results strongly suggest that indirubin-3-oxime prevents H 2 O 2 -induced apoptosis via concurrent inhibiting GSK3β and the ERK pathway in SH-SY5Y cells, providing support for the use of indirubin-3-oxime to treat neurodegenerative disorders caused or exacerbated by oxidative stress.

  8. Portosystemic shunting in portal hypertension: evaluation with portal scintigraphy with transrectally administered I-123 IMP

    International Nuclear Information System (INIS)

    Kashiwagi, T.; Azuma, M.; Ikawa, T.; Takehara, T.; Matsuda, H.; Yoshioka, H.; Mitsutani, N.; Koizumi, T.; Kimura, K.

    1988-01-01

    Portosystemic shunting was evaluated with rectal administration of iodine-123 iodoamphetamine (IMP) in seven patients without liver disease and 53 patients with liver cirrhosis. IMP (2-3 mCi [74-111 MBq]) was administered to the rectum through a catheter. Images of the chest and abdomen were obtained for up to 60 minutes with a scintillation camera interfaced with a computer. In all patients, images of the liver and/or lungs were observed within 5-10 minutes and became clear with time. In patients without liver disease, only liver images could be obtained, whereas the lung was visualized with or without the liver in all patients with liver cirrhosis. The portosystemic shunt index was calculated by dividing counts of lungs by counts of liver and lung. These values were significantly higher in liver cirrhosis, especially in the decompensated stage. Transrectal portal scintigraphy with IMP appears to be a useful method for noninvasive and quantitative evaluation of portosystemic shunting in portal hypertension

  9. Bone scintigraphy in children

    International Nuclear Information System (INIS)

    Mann, M.D.

    2004-01-01

    Full text: Bone scintigraphy is an integral part of the evaluation of bone disease in children. Common indications are suspected infection or inflammation, bone tumours and metastases, trauma and avascular necrosis. In all these disorders the sensitivity of scintigraphy is high. Gallium scintigraphy is often useful in children with clinical signs of infection not responding to treatment but the radiation dose is high. High quality images are essential. They depend on the full participation and co-operation of the child, parents and radiographers, the administration of appropriate analgesics, gentle but firm handling of the child, the injection of the appropriate amount of radiopharmaceutical, good positioning and immobilization, optimised equipment, and the acquisition of a suitable number of counts in an appropriate matrix size. Unless there are specific reasons for not doing so, we routinely perform two phase bone scintigraphy. This usually involves whole body blood pool and delayed images followed by static images of selected areas and, less often, pinhole images or SPECT. The interpretation of bone scan images in children requires knowledge of the age dependent differences in bone metabolism in the developing skeleton and the effect on the appearance of the maturing skeleton. (author)

  10. Regional lung function evaluation with nitrogen-13

    Energy Technology Data Exchange (ETDEWEB)

    Ahluwalia, B; Brownell, G L; Hales, C; Kazemi, H

    1981-10-01

    Regional ventilation and perfusion studies are routinely performed with molecular nitrogen-13 (a short-lived positron emitter), a multicrystal positron camera, and a computer. These studies have the advantage of viewing with equal sensitivity all sections of the lung simultaneously. Nitrogen-13 is less soluble than xenon in blood and therefore allows more accurate ventilation imaging. The short half-life of the radiopharmaceutical allows simultaneous ventilation and perfusion scintigraphy of the lung. Unlike other imaging techniques in which the residual radioactivity persists in the lung for hours, nitrogen-13 is rapidly cleared allowing repetitive imaging. Ventilation and perfusion studies are part of the routine preoperative evaluation for lung cancer resection or for bullectomy in patients with chronic obstructive pulmonary disease and for assessment of pulmonary emboli in the presence of chronic obstructive disease.

  11. The 'fragmented' scintigraphic lung pattern in pulmonary lymphangitic carcinomatosis secondary to breast cancer.

    Science.gov (United States)

    Vattimo, A V; Burroni, L; Bertelli, P; Vella, A; Volterrani, D

    1998-01-01

    Pulmonary lymphangitic carcinomatosis (PLC) is an unusual presentation of diffuse infiltrative lung disease. In this report we present two cases secondary to breast cancer; the diagnosis was made by means of transbronchial lung biopsy or postmortem examination. The goal of this study was to analyze the scintigraphic pattern of pulmonary perfusion performed with technetium-99m macroaggregated albumin (99mTc-MAA) in the hope of achieving improved recognition of PLC and its subsequent diagnosis. Upon admission, both patients underwent routine clinical exams followed by chest X-rays. The second patient also underwent CT examination, and both were ultimately examined using pulmonary perfusion scintigraphy with 99mTc-MAA. In the various exams performed, the most reliable and easily identified diagnostic finding turned out to be a characteristic 'fragmented' lung pattern revealed with the perfusion lung scan. Unfortunately, in both cases the patients' conditions rapidly worsened and death occurred shortly following scintigraphy. We were able to conclude that the recognition of the mentioned fragmented scintigraphic lung pattern may be useful in suspected PLC, whereas the nonspecific clinical presentation of this pathology makes diagnosis extremely difficult, with the most significant results being achieved through a comparison of scintigraphic and high resolution CT data.

  12. Efficacy of two anthelmintic treatments, spinosad/milbemycin oxime and ivermectin/praziquantel in dogs with natural Toxocara spp. infection.

    Science.gov (United States)

    Heredia Cardenas, Rafael; Romero Núñez, Camilo; Miranda Contreras, Laura

    2017-11-30

    Toxocara canis is one of the most important zoonotic parasites of dogs. The aim of the present study was to compare the efficacy of spinosad/milbemycin oxime and ivermectin/praziquantel in dogs naturally infected with Toxocara spp. We studied 200 dogs with a positive diagnosis of Toxocara spp. Through coproparasitoscopic analysis, two study groups of 100 dogs each were assigned: spinosad/milbemycin oxime at a dose of 30-60mg/kg and 0.75-1.0mg/kg, respectively, or ivermectin/praziquantel administered at a dose of 0.2mg/kg and 5mg/kg, respectively. Both groups received a single dose. Three stool samples, one at day 0 before treatment, and at 14 and 28days post-treatment were examined using concentration-flotation techniques. In both treatments, the number of Toxocara spp. eggs decreased; with spinosad/milbemycin oxime treatment, eggs decreased by 87% at 14days (P=0.008) and 94% at 28days after treatment, compared with 71% at day 14 and 88% at day 28 in dogs medicated with ivermectin/praziquantel. The spinosad/milbemycin oxime treated group showed a greater decrease in the number of Toxocara spp. positive dogs compared to the group receiving ivermectin/praziquantel. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Scintigraphy of renal transplant

    International Nuclear Information System (INIS)

    Ramackers, J.M.; Marrast, A.C.; Touraine, J.L.; Peyrin, J.O.

    1995-01-01

    Scintigraphy is useful for monitoring perfusion and function of renal transplant, as well as for diagnosing miscellaneous surgical. This non-invasive imaging technique, which uses no deleterious products, is an attractive alternative for patients. This is especially true for those patients in early post-transplant course, with immunity depression and often impairment of renal function. Otherwise, multiple indices with a large range of inter-patient values has not favoured a methodological and interpretative consensus. Furthermore, the poor specificity of renogram patterns does not allow for discrimination of all etiologies with only one scintigraphy. Nevertheless, follow-up with iterative scintigraphy may be helpful due to the high intra-patient reproducibility and to the early appreciate change of parameters, according to clinical and histological renal post-transplant outcome. (authors). 43 refs., 8 figs

  14. Liver scintigraphy

    International Nuclear Information System (INIS)

    Tateno, Yukio

    1996-01-01

    Liver scintigraphy can be classified into 3 major categories according to the properties of the radiopharmaceuticals used, i.e., methods using radiopharmaceuticals which are (1) incorporated by hepatocytes, (2) taken up by reticulo endothelial cells, and (3) distributed in the blood pool of the liver. Of these three categories, the liver scintigraphy of the present research falls into category 2. Radiopharmaceuticals which are taken up by endothelial cells include 198 Au colloids and 99m Tc-labelled colloids. Liver scintigraphy takes advantage of the property by which colloidal microparticles are phagocytosed by Kupffer cells, and reflect the distribution of endothelial cells and the intensity of their phagocytic capacity. This examination is indicated in the following situations: (i) when you suspect a localized intrahepatic lesion (tumour, abscess, cyst, etc.), (ii) when you want to follow the course of therapy of a localized lesion, (iii) when you suspect liver cirrhosis, (iv) when you want to know the severity of liver cirrhosis or hepatitis, (v) when there is hepatomegaly and you want to determine the morphology of the liver, (vi) differential diagnosis of upper abdominal masses, and (vii) when there are abnormalities of the right diaphragm and you want to know their relation to the liver

  15. The Efficacy Of Milbemycin Oxime In The Treatment Of Naturally Acquired Infestations Of Sarcoptes Scabiei On Dogs

    OpenAIRE

    Xu Q; Guo S; Li J; Wang Y; Shen Z; Yanping Wang; Ying Z; Zhang Z; Fu S; Ma L; Yang L; Wang J; Duanhui Ma

    2013-01-01

    Milbemycin oxime tablets were evaluated for efficacy against sarcoptic mange mites in naturally infested dogs. Sixty-five dogs were allocated to two groups and were housed individually. Fifty of the dogs were treated orally with milbemycin oxime at the proposed dose. The other fifteen were treated orally with vehicle. Study day 0 was defined as the first day of treatment administration. Dogs were treated on days 0, 7 and 14, and efficacy was assessed by counting viable mites recovered from sk...

  16. Scintigraphic diagnosis of silent aspiration following double-sided lung transplantation

    International Nuclear Information System (INIS)

    Toenshoff, G.; Stock, U.; Bohuslavizki, K.H.; Brenner, W.; Costard-Jaeckle, A.; Cremer, J.; Clausen, M.

    1996-01-01

    We present a case of a 25 year old patient who underwent double-sided lung transplantation and suffered from recurrent pneumonia. Silent aspiration was suspected clinically. Aspiration was proved by scintigraphy enabling to discriminate between direct oro-pulmonal aspiration and aspiration after gastro-esophageal reflux. (orig.) [de

  17. Clinical evaluation of scintigraphy for malignant tumors in children

    International Nuclear Information System (INIS)

    Ishii, Katsumi; Aso, Koichi; Yamada, Nobuaki; Horiike, Shigeharu; Matsubayashi, Takashi

    1982-01-01

    X-ray study, Computed tomography, Echography and Scintigraphy are chosen to draw visual images of malignant tumors in children. To obtain higher diagnostic sensitivity, we recommend that 67-Ga-scintigraphy and other different scitigraphy for organs are performed on each child suspected of having malignant tumor. 67-Ga does not have accurate sensitivity for neuroblastoma, but bone scintigraphy with 99m-Tc-labelled phosphate complexes detects neuroblastoma as a positive image. 67-Ga scintigraphy and other different radiopharmaceutical scintigraphy should be used for primary visualization and control of malignant tumor in children. Serial scintigraphy at proper intervals are very effective to detect local recurrence and metastasis of malignant tumors. (author)

  18. Significance of thymic scintigraphy

    International Nuclear Information System (INIS)

    Baba, Hiromi; Oshiumi, Yoshihiko; Nakayama, Chikashi; Morita, Kazunori; Koga, Ichinari

    1978-01-01

    Thymic scintigraphy by 67 Ga-citrate and 75 Se-methionine was done on 6 cases of thymoma, and 5 cases of myasthenia gravis. Scan was positive on 5 of 6 cases of thymoma. All patients with malignant thymoma were positive. Among the 7 cases of myasthenia gravis, scintigrams revealed 2 thymomas and 1 hyperplasia on whom no thymic mass suspected. Thymic scintigraphy is useful examination when dealing with myasthenia gravis. (auth.)

  19. Lung scintigraphy evaluation in workers exposed to abrasive dusts

    International Nuclear Information System (INIS)

    Terra Filho, Mario

    1995-01-01

    The production process of abrasives use aluminium, or silicon carbide a synthetic material with a hardness only slightly less than that of a diamond. It is popularly known as carborundum since it was first manufactured as an abrasive in 1891, produced by the fusion of high grade silica and petroleum coke with sawdust. For many years silicon carbide was thought not to give rise to pulmonary lesions. Recently several researchers suggested the existence of a carborundum pneumoconiosis. The aim of this study was to evaluate the role of the pulmonary clearance of 99m Technetium chelated to diethylene-triamine penta-acetate ( 99m Tc DTPA), and 67 Gallium lung scanning in workers exposed to abrasive dusts. Thirty seven subjects, 13 smokers and 24 nonsmokers and ex smokers were studied. In 32 (86,48%) 67 Gallium lung scanning was positive including 13 (40,62%) retired workers. We conclude that non smoking workers of abrasives plants have a pulmonary alveolar epithelial permeability disturbance similar as observed in smoking workers and smoking controls. Most workers, ex-workers of these industries and in patients with carborundum pneumoconiosis there is an evidence of pulmonary inflammation measured with abnormal 67 Gallium lung scan. (author)

  20. Multiple QSAR models, pharmacophore pattern and molecular docking analysis for anticancer activity of α, β-unsaturated carbonyl-based compounds, oxime and oxime ether analogues

    Science.gov (United States)

    Masand, Vijay H.; El-Sayed, Nahed N. E.; Bambole, Mukesh U.; Quazi, Syed A.

    2018-04-01

    Multiple discrete quantitative structure-activity relationships (QSARs) models were constructed for the anticancer activity of α, β-unsaturated carbonyl-based compounds, oxime and oxime ether analogues with a variety of substituents like sbnd Br, sbnd OH, -OMe, etc. at different positions. A big pool of descriptors was considered for QSAR model building. Genetic algorithm (GA), available in QSARINS-Chem, was executed to choose optimum number and set of descriptors to create the multi-linear regression equations for a dataset of sixty-nine compounds. The newly developed five parametric models were subjected to exhaustive internal and external validation along with Y-scrambling using QSARINS-Chem, according to the OECD principles for QSAR model validation. The models were built using easily interpretable descriptors and accepted after confirming statistically robustness with high external predictive ability. The five parametric models were found to have R2 = 0.80 to 0.86, R2ex = 0.75 to 0.84, and CCCex = 0.85 to 0.90. The models indicate that frequency of nitrogen and oxygen atoms separated by five bonds from each other and internal electronic environment of the molecule have correlation with the anticancer activity.

  1. Successful oxime therapy one hour after soman intoxication in the rat

    NARCIS (Netherlands)

    Wolthuis, O.L.; Kepner, L.A.

    1978-01-01

    The bisquarternary mono-oxime HI-6, and to a lesser extent HS-6, caused functional recovery of neuromuscular transmission in vivo and in vitro when given 60 min after soman, i.e. when the soman-cholinesterase (AChE) complex is said to be fully 'aged'. Atropinised rats, with the tracheas intubated,

  2. Hepatobiliary scintigraphy

    International Nuclear Information System (INIS)

    Velchik, M.G.

    1988-01-01

    This chapter describes the role of nuclear medicine in the evaluation of the hepatobiliary system. The technical aspects of hepatobiliary scintigraphy, or cholescintigraphy (radiopharmaceutical, radiation dosimetry, instrumentation, and method) are briefly presented, followed by a discussion of each of the indications for such examination. Its relative advantages and disadvantages with respect to alternative radiographic examinations are emphasized. Logical, efficient, cost-effective sequences of diagnostic studies are recommended whenever appropriate in order to derive the maximum information with the least time and expense. It is hoped that the reader will come away with an appreciation of the type of diagnostic information provided by hepatobiliary scintigraphy, its accuracy, its application in the workup of the patient with hepatobiliary disease, and its strengths and limitations compared with other radiologic studies

  3. Quantitative study on lung volume and lung perfusion using SPECT and CT in thoracal tumors

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Strauss, L.G.

    1988-01-01

    22 patients with space occupying lesions in the thoracal region were investigated by computer tomography and by perfusion scintigraphy using SPECT. In order to evaluate the CT images quantitatively, the lung volume was determined using approximation method and compared with the perfusion in the SPECT study. For this, anatomically equivalent transaxial SPECT slices had been coordinated to the CT slices. Between the determined lung volumes and the activity in the ocrresponding layers, a statistically significant correlation was found. It could be shown that the stronger perfusion, frequently observed at the right side of the healthy lung, may be explained by an higher volume of the right pulmonary lobe. Whereas in benign displacing processes the relation activity to volume was similar to the one of the healthy lung, a strongly reduced perfusion together with inconspicuous lung volumes became apparent with malignant tumors. In addition to the great morphological evidence of CT and SPECT studies, additional informations regarding the dignity of displacing processes may be derived from the quantitative evaluation of both methods. (orig.) [de

  4. Refinement of Structural Leads for Centrally Acting Oxime Reactivators of Phosphylated Cholinesterases*

    Science.gov (United States)

    Radić, Zoran; Sit, Rakesh K.; Kovarik, Zrinka; Berend, Suzana; Garcia, Edzna; Zhang, Limin; Amitai, Gabriel; Green, Carol; Radić, Božica; Fokin, Valery V.; Sharpless, K. Barry; Taylor, Palmer

    2012-01-01

    We present a systematic structural optimization of uncharged but ionizable N-substituted 2-hydroxyiminoacetamido alkylamine reactivators of phosphylated human acetylcholinesterase (hAChE) intended to catalyze the hydrolysis of organophosphate (OP)-inhibited hAChE in the CNS. Starting with the initial lead oxime RS41A identified in our earlier study and extending to the azepine analog RS194B, reactivation rates for OP-hAChE conjugates formed by sarin, cyclosarin, VX, paraoxon, and tabun are enhanced severalfold in vitro. To analyze the mechanism of intrinsic reactivation of the OP-AChE conjugate and penetration of the blood-brain barrier, the pH dependence of the oxime and amine ionizing groups of the compounds and their nucleophilic potential were examined by UV-visible spectroscopy, 1H NMR, and oximolysis rates for acetylthiocholine and phosphoester hydrolysis. Oximolysis rates were compared in solution and on AChE conjugates and analyzed in terms of the ionization states for reactivation of the OP-conjugated AChE. In addition, toxicity and pharmacokinetic studies in mice show significantly improved CNS penetration and retention for RS194B when compared with RS41A. The enhanced intrinsic reactivity against the OP-AChE target combined with favorable pharmacokinetic properties resulted in great improvement of antidotal properties of RS194B compared with RS41A and the standard peripherally active oxime, 2-pyridinealdoxime methiodide. Improvement was particularly noticeable when pretreatment of mice with RS194B before OP exposure was combined with RS194B reactivation therapy after the OP insult. PMID:22343626

  5. The impact of different imaging modalities of 67Ga scintigraphy on the image quality and the ability in detection of lesions

    International Nuclear Information System (INIS)

    Liu Xiuqin; Li Wenchan; Zhang Jianfei; Yao Zhiming

    2009-01-01

    Objective: 67 Ga scintigraphy is an important method in detection of active sarcoidosis. The aim of this research was to study the influence of planar and tomography. with and without CT attenuation correction (AC and NAC), on 67 Ga images on the image quality and the ability in detection of lesions. Methods: Thirty one patients (13 male, 18 female, age range: 33-87 years)with sarcoidosis underwent 67 Ga planar and tomographic scans. AC and NAC.The imaging quality and the ability in detection of hyper-radioactive lymph nodes in lung hilar and mediastinal(1esion) among the planar, AC and NAC images were compared. The paired t-test and χ 2 -test were used for data analysis with SPSS 10.0 software. Results: From planar, NAC to AC, the image quality was better and better in proper order (χ 2 = 25.88, P 67 Ga tomographic scintigraphy can impmve the ability in detection of hyperradioactive lung hilar and mediastinal lymph nodes compared with planar image does. CT AC for 67 Ga tomography can improve the tomographic imaging quality. (authors)

  6. Esophageal scintigraphy: A comparison with esophagoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kjellen, G.; Andersson, P.; Sandstroem, S.

    1987-01-01

    Fifty consecutive patients with different esophageal symtoms were investigated with esophageal endoscopy, transit scintigraphy, and gastroesophageal (GE) scintigraphy with extra-abdominal compression. Scintigraphic findings were abnormal in 27 of those 31 patients (87%) who were classified as abnormal at endoscopy. A prolonged transit time was the commonest finding, but hiatal hernia and GE reflux were also found. However, the scintigraphic procedure showed abnormalities in 6 of 19 (31%) patients who were classified as normal at endoscopy. Esophageal scintigraphy is recommended as a screening test before endoscopy is decided on. 20 refs.

  7. Myocardial scintigraphy

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Hisada, Kinichi

    1982-01-01

    Among the various methods of image diagnosis of the cardiovascular disorder, nuclear cardiology provides noninvasive means for evaluation of myocardial perfusion as well as morphological and functional informations. In this article, clinical application and image diagnosis of myocardial scintigraphy including Tl-201 myocardial perfusion scintigraphy, single photon emission computed tomography with Tl-201, acute myocardial infarction scintigraphy with Tc-99m-pyrophosphate and Ga-67 imaging of the heart, were discussed. Multiplanar imaging of the heart with Tl-201 after stress and at redistribution was the accepted method for detection and evaluation of the ischemic heart disease. Although it achieved high sensitivity and specificity for ischemic heart disease, detection of the small ischemia and quantation of the regional Tl-201 accumulation were difficult with conventional multiplanar imaging. Application of emission computed tomography improved detectability and quantitativity of the ischemia. However, 7-pinhole tomography did not increase the diagnostic accuracy significantly. It had limited clinical applicability due to poor quantitativity in spite of improved image contrast and its tomographic nature. Advantage and limitation of these tomographic imaging and multiplanar imaging were discussed. Problems and prognostic significance of pyrophosphate imaging of the acute myocardial infarction were also discussed. Visualization of the heart with Ga-67 was helpful for identification of the tumor or inflammation of the heart as well as evaluation of the effect of the therapy. (author)

  8. Studies on the polymerization of acrolein oxime, 13

    International Nuclear Information System (INIS)

    Ota, Tadatoshi; Mori, Yoshikazu; Tamai, Harumi; Masuda, Seizo; Tanaka, Masami.

    1980-01-01

    The radiation-induced polymerization of acrolein oxime was carried out at temperatures ranging from room temperature to -78 0 C, and the resulting low molecular products were analyzed by gas chromatography-mass spectrometry. Acetaldoxime, propionaldoxime, propenylhydroxylamines, dioximes etc. were obtained. Initial processes of the polymerization are discussed on the basis of these reaction products. The present work offers further corroborating evidence for the already-described postulation that an anionic mechanism is operative above room temperature, and a cationic mechanism is predominant below -23 0 C. (author)

  9. Scintigraphy of the heart using sup(99m)Tc diphosphonate in combination with selective coronary perfusion scintigraphy and coronaroangiography

    International Nuclear Information System (INIS)

    Neumann, G.; Trenckmann, H.; Duck, H.J.; Katzschmann, R.; Neugebauerova, A.; Schneider, G.; Gottschild, D.

    1980-01-01

    In 45 patients with ischemic heart disease the results obtained by myocardial scintigraphy using technetium-99m diphosphonate (Tc-99m-DP) were compared with those obtained at selective coronary angiography and selective coronary perfusion scintigraphy. The cumulation of activity in the heart muscle was seen in twelve patients. This group is analyzed in the present paper in more detail. The ventriculographic examination of the left ventricle showed disturbed motility of the wall in six patients, of whom five had a positive myocardial scintigram. In view of this, myocardial scintigraphy using Tc-99m-DP may be considered a complementary, non-invasive method for proving significant disturbances of the motility of the heart wall. Positive myocardial scintigrams were also found in angna pectoris, in a patient after aorto-coronary bypass, in cardiomyopathy and myocarditis. In view of the fact that myocardial scintigraphy using Tc-99m-DP is capable of proving disturbances of cells of the heart muscle taking place at the moment, conclusions can be drawn as to the activity in the heart muscle. It further follows that myocardial scintigraphy may be significant in indicating the aorto-coronary bypass. We failed to prove an unequivocal correlation between myocardial scintigraphy, the number of sclerotically changed coronary vessels and the degree of their narrowing. An immediate relationship could not be proved between the extent of perfusion disturbance and the results of myocardial scintigraphy

  10. Role of cineoesophageal scintigraphy in primary and secondary oesophageal motility disorders. About a 12000 radionuclide transit study experience; Place de la cine-oesophagoscintigraphie dans les troubles moteurs oesophagiens primitifs et secondaires. A propos de 12000 explorations

    Energy Technology Data Exchange (ETDEWEB)

    Guillet, J.; Role, C.; Imbert, Y.

    1996-12-31

    Cineoesophageal scintigraphy (COS) and evaluation of oesophageal motility disorders. A 12 000 COS experience with {sup 99m}TC-sulfur colloid radiolabeled liquids is detailed. Functional qualitative and quantitative isotopic imaging parameters describe the propulsion abnormalities: mainly achalasia, diffuse esophageal spasm, nutcracker esophagus, non-specific motor disorders, systemic sclerosis, diabetes. Respective advantages and drawbacks of manometry and scintigraphy are discussed. Manometry only can measure pressures, scintigraphy only can measure bolus propulsion by peristaltic waves. Physiological and comfortable conditions, sensitivity, quantitative functional imaging, evidence of lung aspiration when swallowing advantage. (authors). 117 refs., 14 figs., 3 tabs.

  11. Catalytic activity of some oxime-based Pd(II-complexes in Suzuki coupling of aryl and heteroaryl bromides in water

    Directory of Open Access Journals (Sweden)

    Kamal M. Dawood

    2017-05-01

    Full Text Available The catalytic activity of four Pd(II-complexes of benzoazole-oximes was extensively studied in Suzuki–Miyaura C–C cross coupling reactions in water, as an eco-friendly green solvent, under both thermal heating as well as microwave irradiation conditions. The cross-coupling reactions included different activated and deactivated aryl- or heteroaryl-bromides with several arylboronic acids. The protected oxime-complexes were found to be more efficient than the free ones.

  12. Depiction of residual emboli following pulmonary embolism with thrombotic scintigraphy

    International Nuclear Information System (INIS)

    Takahashi, Keiko; Ohnishi, Mamoru; Hiromoto, Kenji; Ueda, Atsunori; Ohyanagi, Mitsumasa; Naruse, Hitoshi

    2005-01-01

    In the treatment of pulmonary embolism (PE), the presence of residual emboli is known to seriously affect the recurrence and prognosis. We attempted to depict the residual emboli in the subacute stage of PE using indium-111-oxine labeled platelet scintigraphy (In-plt). In-plt was performed on 22 patients with PE who showed an improvement according to lung perfusion scintigraphy. Their accumulation was assessed along with the blood coagulation ability measured on the same day. In addition, radioisotope venography (RI-veno) was performed simultaneously with In-plt to measure the circulatory findings in the lower limb for comparison. All patients received systemic heparin during the acute stage and received warfarin at the time of testing. Accumulation of In-plt was observed in 7 patients (32%), and positive signals were found in the lower limbs or pelvic cavity in all cases. Two patients were suspected of having poor lower limb circulation from their RI-veno findings, and these findings were largely consistent with the areas of In-plt accumulation. Some emboli persist after extensive anti-coagulation therapy. The use of In-plt is effective in determining the therapeutic measures and assessing the prognosis as this method allows us to clearly depict the existence of such emboli. (author)

  13. Inhibition, recovery and oxime-induced reactivation of muscle esterases following chlorpyrifos exposure in the earthworm Lumbricus terrestris

    International Nuclear Information System (INIS)

    Collange, B.; Wheelock, C.E.; Rault, M.; Mazzia, C.; Capowiez, Y.; Sanchez-Hernandez, J.C.

    2010-01-01

    Assessment of wildlife exposure to organophosphorus (OP) pesticides generally involves the measurement of cholinesterase (ChE) inhibition, and complementary biomarkers (or related endpoints) are rarely included. Herein, we investigated the time course inhibition and recovery of ChE and carboxylesterase (CE) activities in the earthworm Lumbricus terrestris exposed to chlorpyrifos, and the ability of oximes to reactivate the phosphorylated ChE activity. Results indicated that these esterase activities are a suitable multibiomarker scheme for monitoring OP exposure due to their high sensitivity to OP inhibition and slow recovery to full activity levels following pesticide exposure. Moreover, oximes reactivated the inhibited ChE activity of the earthworms exposed to 12 and 48 mg kg -1 chlorpyrifos during the first week following pesticide exposure. This methodology is useful for providing evidence for OP-mediated ChE inhibition in individuals with a short history of OP exposure (≤1 week); resulting a valuable approach for assessing multiple OP exposure episodes in the field. - Esterase inhibition combined with oxime reactivation methods is a suitable approach for monitoring organophosphate contamination

  14. Inhibition, recovery and oxime-induced reactivation of muscle esterases following chlorpyrifos exposure in the earthworm Lumbricus terrestris

    Energy Technology Data Exchange (ETDEWEB)

    Collange, B. [Universite d' Avignon et des Pays de Vaucluse, UMR 406 Abeilles et Environnement, Site AGROPARC, F-84914, Avignon Cede 09 (France); Wheelock, C.E. [Division of Physiological Chemistry II, Department of Medical Biochemistry and Biophysics, Karolinska Institutet, SE 171 77, Stockholm (Sweden); Rault, M.; Mazzia, C. [Universite d' Avignon et des Pays de Vaucluse, UMR 406 Abeilles et Environnement, Site AGROPARC, F-84914, Avignon Cede 09 (France); Capowiez, Y. [INRA, Unite PSH, Site AGROPARC, F-84914 Avignon Cedex 09 (France); Sanchez-Hernandez, J.C., E-mail: juancarlos.sanchez@uclm.e [Laboratory of Ecotoxicology, Faculty of Environmental Science, University of Castilla-La Mancha, Avda. Carlos III s/n, 45071, Toledo (Spain)

    2010-06-15

    Assessment of wildlife exposure to organophosphorus (OP) pesticides generally involves the measurement of cholinesterase (ChE) inhibition, and complementary biomarkers (or related endpoints) are rarely included. Herein, we investigated the time course inhibition and recovery of ChE and carboxylesterase (CE) activities in the earthworm Lumbricus terrestris exposed to chlorpyrifos, and the ability of oximes to reactivate the phosphorylated ChE activity. Results indicated that these esterase activities are a suitable multibiomarker scheme for monitoring OP exposure due to their high sensitivity to OP inhibition and slow recovery to full activity levels following pesticide exposure. Moreover, oximes reactivated the inhibited ChE activity of the earthworms exposed to 12 and 48 mg kg{sup -1} chlorpyrifos during the first week following pesticide exposure. This methodology is useful for providing evidence for OP-mediated ChE inhibition in individuals with a short history of OP exposure (<=1 week); resulting a valuable approach for assessing multiple OP exposure episodes in the field. - Esterase inhibition combined with oxime reactivation methods is a suitable approach for monitoring organophosphate contamination

  15. Selective and Efficient Solvent Extraction of Copper(II Ions from Chloride Solutions by Oxime Extractants

    Directory of Open Access Journals (Sweden)

    Zahra Kaboli Tanha

    2016-06-01

    Full Text Available Oxime extractants 3-tert-butyl-2-hydroxy-5-methyl benzaldehyde oxime (HL1 and 3-tert-butyl-2-hydroxy-5-methoxy benzaldehyde oxime (HL2 were synthesized and characterized by conventional spectroscopic methods. Suitable lipophilic nature of the prepared extractants allowed examining the ability of these molecules for extraction-separation of copper from its mixture with normally associated metal ions by performing competitive extraction experiments of Cu(II, Co(II, Ni(II, Zn(II, Cd(II and Pb(II ions from chloride solutions. Both ligands transfer selectively the copper ions into dichloromethane by a cation exchange mechanism. Conventional log-log analysis and isotherm curves showed that Cu(II ions are extracted as the complexes with 1:2 metal to ligand ratio by both extractants. Verification of the effect of the organic diluent used in the extraction of copper ions by HL1 and HL2 demonstrated that the extraction efficiency varies as: dichloromethane ~ dichloroethane > toluene > xylene > ethylacetate. Time dependency investigation of the extraction processes revealed that the kinetics of the extraction of copper by HL2 is more rapid than that of HL1. The application of the ligands for extraction-separation of copper ions from leach solutions of cobalt and nickel-cadmium filter-cakes of a zinc production plants was evaluated.

  16. Recent advances in gastric emptying scintigraphy

    International Nuclear Information System (INIS)

    Urbain, J.L.C.; Mayeur, S.M.

    1996-01-01

    Gastric emptying scintigraphy was introduced more than 25 years ago by Grittith and still remains the gold standard to assess gastric emptying. Test meals, radiopharmaceuticals and acquisition procedures have been refined and optimized over the years and the test procedure is now pretty well standardized. However, in its most common use, gastric emptying scintigraphy provides little information on gastric physiology. Over the last decade, modelling of the liquid and solid emptying curves have brought some insight in the complex gastric physiology. Compartmental analysis of the stomach has also provided information on the pathophysiological mechanisms of delayed gastric emptying. Over the past 5 years, the most dramatic development in gastric emptying scintigraphy has been the introduction of Digital Antral Scintigraphy (DAS). Digital Antral scintigraphy basically consists in dynamically imaging of the stomach and the use of a refined Fourier transform processing method. This new procedure allows for the visualization of antral contractions and, alike manometry, permits quantitative characterization on the frequency and amplitude of these contractions. Overall, this new procedure provides a unique, non invasive tool to characterize gastric motility, to define the pathophysiologic mechanisms of gastric motor disorders and to evaluate the effect of new gastro-kinetic compounds. (authors). 241 refs., 5 figs

  17. Synthesis of Imidazopyridines via Copper-Catalyzed, Formal Aza-[3 + 2] Cycloaddition Reaction of Pyridine Derivatives with α-Diazo Oxime Ethers.

    Science.gov (United States)

    Park, Sangjune; Kim, Hyunseok; Son, Jeong-Yu; Um, Kyusik; Lee, Sooho; Baek, Yonghyeon; Seo, Boram; Lee, Phil Ho

    2017-10-06

    The Cu-catalyzed, formal aza-[3 + 2] cycloaddition reaction of pyridine derivatives with α-diazo oxime ethers in trifluoroethanol was used to synthesize imidazopyridines via the release of molecular nitrogen and elimination of alcohol. These methods enabled modular synthesis of a wide range of N-heterobicyclic compounds such as imidazopyridazines, imidazopyrimidines, and imidazopyrazines with an α-imino Cu-carbenoid generated from the α-diazo oxime ethers and copper.

  18. A parathyroid scintigraphy case study

    International Nuclear Information System (INIS)

    O'Leary, Desiree

    2005-01-01

    Background: There has been much debate concerning the most suitable protocol for parathyroid scintigraphy; the merits of various radiopharmaceuticals versus the correct imaging protocol to visualise both ectopic and anatomically placed adenomas against the various equipment choices have been debated. Aim: To demonstrate, through the use of a case study, the necessity of changing imaging protocols for parathyroid scintigraphy where a definitive imaging diagnosis is absent in the face of strong clinical suspicion. Method: Use is made of Tc99mMIBI, full field chest scintigraphy, a clearly defined imaging protocol and SPECT imaging to locate ectopic parathyroid tissue in a female patient with significant symptoms of parathyroid hyperfunction. Results: A single hyperfunctioning adenoma is located in the pre-carinal area of the mediastinum. Using a radioguided surgical technique the hyperfunctioning tissue is excised and confirmed by histopathology. Conclusion: Whilst a dramatic reduction in patient symptoms was not seen immediately in this patient, the symptoms of the illness have been subsiding since January 2003. This case study demonstrates the necessity of changing imaging protocols for parathyroid scintigraphy where a definitive imaging diagnosis is absent in the face of strong clinical suspicion

  19. Development and validation of a FIA/UV-vis method for pK(a) determination of oxime based acetylcholinesterase reactivators.

    Science.gov (United States)

    Musil, Karel; Florianova, Veronika; Bucek, Pavel; Dohnal, Vlastimil; Kuca, Kamil; Musilek, Kamil

    2016-01-05

    Acetylcholinesterase reactivators (oximes) are compounds used for antidotal treatment in case of organophosphorus poisoning. The dissociation constants (pK(a1)) of ten standard or promising acetylcholinesterase reactivators were determined by ultraviolet absorption spectrometry. Two methods of spectra measurement (UV-vis spectrometry, FIA/UV-vis) were applied and compared. The soft and hard models for calculation of pK(a1) values were performed. The pK(a1) values were recommended in the range 7.00-8.35, where at least 10% of oximate anion is available for organophosphate reactivation. All tested oximes were found to have pK(a1) in this range. The FIA/UV-vis method provided rapid sample throughput, low sample consumption, high sensitivity and precision compared to standard UV-vis method. The hard calculation model was proposed as more accurate for pK(a1) calculation. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Electrochemical determination of 5-dodecylsalicylaldoxime and 2′-hydroxy-5′-nonylacetophenone oxime in commercial extractants

    Directory of Open Access Journals (Sweden)

    Elizalde María P.

    2017-01-01

    Full Text Available A differential pulse voltammetric method using a hanging mercury drop electrode (HMDE was optimized for the determination of 5-dodecylsalicylaldoxime in hydro-alcoholic solutions using factorial and central composite designs. The Taguchi design methodology was used to extend the formerly optimized method to the determination of 2′-hydroxy-5′-nonylacetophenone oxime. The method was successfully applied to quantify 5-dodecylsalicylaldoxime and 2′-hydroxy-5′-nonylacetophenone oxime in samples of commercial extractants over the concentration range 0.05–2.45 and 0.07–0.82 mg L-1, respectively, with detection limits of 0.034 and 0.019 mg L-1, respectively.

  1. Synthesis and Antifungal Activity of Novel 3-Caren-5-One Oxime Esters.

    Science.gov (United States)

    Huang, Min; Duan, Wen-Gui; Lin, Gui-Shan; Li, Kun; Hu, Qiong

    2017-09-12

    A series of novel 3-caren-5-one oxime esters were designed and synthesized by multi-step reactions in an attempt to develop potent antifungal agents. Two E - Z stereoisomers of the intermediate 3-caren-5-one oxime were separated by column chromatography for the first time. The structures of all the intermediates and target compounds were confirmed by UV-Vis, FTIR, NMR, ESI-MS, and elemental analysis. The antifungal activity of the target compounds was preliminarily evaluated by the in vitro method against Fusarium oxysporum f. sp. cucumerinum , Physalospora piricola , Alternaria solani , Cercospora arachidicola , Gibberella zeae, Rhizoeotnia solani , Bipolaris maydis , and Colleterichum orbicalare at 50 µg/mL. The target compounds exhibited best antifungal activity against P. piricola , in which compounds ( Z )- 4r (R = β -pyridyl), ( Z )- 4q (R = α -thienyl), ( E )- 4f' (R = p -F Ph), ( Z )- 4i (R = m -Me Ph), ( Z )- 4j (R = p -Me Ph), and ( Z )- 4p (R = α -furyl) had inhibition rates of 97.1%, 87.4%, 87.4%, 85.0%, 81.9%, and 77.7%, respectively, showing better antifungal activity than that of the commercial fungicide chlorothanil. Also, compound ( Z )- 4r (R = β -pyridyl) displayed remarkable antifungal activity against all the tested fungi, with inhibition rates of 76.7%, 82.7%, 97.1%, 66.3%, 74.7%, 93.9%, 76.7% and 93.3%, respectively, showing better or comparable antifungal activity than that of the commercial fungicide chlorothanil. Besides, the E-Z isomers of the target oxime esters were found to show obvious differences in antifungal activity. These results provide an encouraging framework that could lead to the development of potent novel antifungal agents.

  2. SYNTHESIS OF OXIMES WITH THE DOPED POTASSIUM FLUORIDE ANIMAL BONE MEAL AS A CATALYST

    Directory of Open Access Journals (Sweden)

    M. AIT TALEB

    2017-12-01

    Full Text Available The potassium fluoride doped Animal Bone Meal (KF/ABM was prepared and characterized using several techniques to identify the structural properties. After, it has been used as a new and eco-friendly catalyst for the preparation of from aldehydes and ketones oximes under solvent-free conditions. It is clearly shown that this reaction (using this catalyst can lead to the corresponding oximes in good yields (80 % to excellent yields (96 %. In the case of dissymmetric aldehydes and ketones, this catalyst can lead to a mixture of Z- and E- isomers (Z/E = 86/14–90/10. The remarkable advantages of this catalyst are high conversion, short reaction times, cleaner reaction profiles, reusability up to 8 times without significant loss of activity, and reduction in catalyst toxicity.

  3. Comparison of computed tomography and 57Co-bleomycin scintigraphy in staging the mediastinal lymph nodes of patients with non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Laan, J.G. van der; Brink, A. van den; Boer, W.J. de; Piers, D.A.; Beekhuis, H.; Kengen, R.A.

    1990-01-01

    The value of computed tomography (CT) and of 57 Co-bleomycin scintigraphy ( 57 Co-BLM) in staging the mediastinal lymph nodes was compared in 28 patients suffering from non-small-cell lung cancer. The results were assessed against the pathological findings obtained during thoracotomy or mediastinoscopy. CT staging of the mediastinum had a sensitivity of 75%, a specificity of 80%, an accuracy of 79%, a positive predictive index of 60% and a negative predictive index of 89%. 57 Co-BLM scintigraphic staging had a sensitivity of 43%, a specificity of 94%, and accuracy of 80%, a positive predictive index of 75% and a negative predictive index of 81%. In this small series these differences were not statistically significant; it thus appears that CT and 57 Co-BLM are of equal value in staging the mediastinum. Mediastinoscopy is not contributory in case of a negative CT or 57 Co-BLM. A positive CT or 57 Co-BLM, however, indicates the need for histological verification of the mediastinal findings. (orig.) [de

  4. Tc-99m erythromycin lactobionate inhalation scintigraphy in parenchymal lung diseases

    Energy Technology Data Exchange (ETDEWEB)

    Durak, Hatice E-mail: hdurak@kordon.deu.edu.tr; Aktogu, Serir; Degirmenci, Berna; Sayit, Elvan; Ertay, Tuerkan; Dereli, Sevket

    1999-08-01

    We have investigated Technetium 99m erythromycin lactobionate (Tc 99m EL) clearance from the lungs after inhalation, in the presence of an alveolitis. Eighteen patients (6 sarcoidosis, 7 idiopathic fibrosis, and 5 miliary tuberculosis) were imaged after the patients inhaled 1,110 MBq of Tc 99m EL. Clearance half time for the first 45 min, for 24 h, and retention at 24 h correlated with percentage of lymphocytes in bronchoalveolar lavage fluid (BAL) (r=.729, r=.883, and r=.826, respectively). There was a positive correlation between peripheral penetration (PP) and forced expiratory volume in 1 s (FEV{sub 1}) (r=.806) and forced vital capacity (FVC) (r=.781). Retention was more marked in sarcoidosis compared with tuberculosis (0.025lung imaging may reflect the pulmonary function impairment in parenchymal lung diseases. Retention of Tc 99m EL may be related to number of BAL cells or presence of a lymphocytic alveolitis. Long residency time of Tc 99m EL in the lungs implies that erythromycin can also be administered by inhalation for therapeutic purposes.

  5. Myocardial rest iodine-123-β-methyl-iodophenyl-pentadecanoic acid scintigraphy compared with dipyridamole stress thallium-201 scintigraphy in unstable angina

    International Nuclear Information System (INIS)

    Misumi, Ikuo; Kimura, Yoshihiro; Hokamura, Youichi; Yamabe, Hiroshige; Ueno, Kazuhiro

    1998-01-01

    Twelve patients with stable angina and 12 patients with unstable angina underwent rest iodine-123-β-methyl-iodophenyl-pentadecanoic acid (BMIPP), dipyridamole stress thallium scintigraphy and delayed thallium scintigraphy. In stable angina, sensitivity for detecting ischemic segments was higher in dipyridamole thallium (74%) than rest BMIPP (48%) images (p<0.05), but there was no significant difference between the 2 images in unstable angina. In unstable angina, the incidence of segments with higher defect scores on BMIPP images than on delayed thallium images and the opposite pattern was 27 and 5 (p<0.01). In stable angina, there was no difference. The mean defect score on BMIPP (6.3±5.6) was higher than that on delayed thallium scintigraphy (2.9±2.7) and it was almost the same as on the initial dipyridamole stress test (6.5±5.2). In conclusion, BMIPP scintigraphy is safer and may be as useful in detecting myocardial ischemia in patients with unstable angina as thallium scintigraphy. (author)

  6. Clinical studies on combined ventilation (sup(81m)Kr)/perfusion (sup(99m)Tc-MAA) scintigraphy. With special reference to the 'mismatch' patterns and their significance

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Keiichiro; Miyamae, Tatsuya [Saitama Medical School (Japan)

    1983-01-01

    One hundred fifty patients having pulmonary disease underwent pulmonary scintigraphy sequentially with sup(99m)Tc-MAA and sup(81m)Kr gases. Scintigrams of matched defect were obtained from 113 (75.3%) of the 150 patients, considered to be nonspecific universal pattern of a pulmonary disease. Scintigrams of mismatched defect (absent perfusion and homogeneous ventilation) were obtained from 20 patients (13.3%), including 6 with lung carcinoma, 3 with pulmonary embolism, 3 with connective tissue disease, 2 with aortitis syndrome and 6 with other diseases. Scintigrams of mismatch with impaired ventilation and normal perfusion were mainly seen in chronic obstructive lung diseases. Of the 10 patients with bronchial asthma, 5 had scintigrams of improved ventilation after intravenous injection of 250 mg aminophilline, but none of patients with emphysema. The combined scintigraphy has made significant contributions to diagnosis and management of patients with pulmonary disease where the chest X-ray is unhelpful.

  7. Bone scintigraphy for horses

    International Nuclear Information System (INIS)

    Jahn, Werner

    2010-01-01

    Scintigraphy (bone scan) is being used approximately since 1980 in the horse under general anaesthesia. With the construction of custom-made overhead gantries for gamma-cameras scintigraphy found widespread entry in big equine referral hospitals for bone-scanning of the standing horse. Indications for the use of a bone scan in the horse are inflammatory alterations in the locomotor apparatus. It is primarily used for diagnosis of lameness of unknown origin, suspect of stress fracture or hairline fracture and for horses with bad riding comfort with suspected painful lesions in the spine. (orig.)

  8. Giant tumor thrombus in the right atrium clearly detected by /sup 111/In-oxine labeled platelet scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, T; Ishikawa, N; Satoh, A; Masuda, Y; Hiramatsu, Y; Akisada, M; Sakakibara, Y

    1985-07-01

    A 54-year-old man was admitted to hospital with a 3-month history of progressive dyspnea with coughing. A giant right atrial mass, originating from a hepatocellular carcinoma, was visualized by computed tomography, and digital subtraction angiography. The volume if the right atrial mass was increasing rapidly. It was therefore essential to determine whether this giant mass was a tumor thrombus or a multiplication of the hepatocellular carcinoma. /sup 111/In-oxine labeled platelet scintigraphy revealed active accumulation in the right atrium caused by the presence of active platelet deposition, and slight accumulation in the lung fields probably due to embolic showers originating from the tumor thrombus in the right atrium. This is the first case report showing that /sup 111/In-oxine labeled platelet scintigraphy can aid in confirming the nature of a giant tumor thrombus in the right atrium and can clarify the pathogenesis of the respiratory symptoms.

  9. Clinical experience of 123I-IMP scintigraphy in detecting vertebral bone metastases of hepatocellular carcinoma. A comparison with bone scintigraphy with 99mTc-MDP

    International Nuclear Information System (INIS)

    Suto, Y.; Iwamiya, T.; Tanigawa, N.; Shabana, M.; Ohta, Y.

    1994-01-01

    123 I-IMP and bone scintigraphy with 99m Tc-MDP were consecutively performed in patients with vertebral bone metastases from hepatocellular carcinoma and lumbar spondylosis deformans in a 7-day interval or shorter. The intensity of uptake was compared. Eighteen of the 20 metastatic lesions (90%) were classified as increased uptake areas in 123 I-IMP scintigraphy. MDP-scintigraphy disclosed 16 metastatic lesions (80%), 9 as ''hot'' lesions (56%) and 7 as ''cold'' lesions (44%). 123 I-IMP scintigraphy was negative in all 12 lesions of lumbar spondylosis deformans. Compared to MDP-scintigraphy, 123 I-IMP scintigraphy was more sensitive in detecting vertebral bone metastases of hepatocellular carcinoma with smaller rates of false-positive and false-negative findings. (orig./MG)

  10. Hemodynamic evaluation of portal blood flow with transrectal scintigraphy using sup 123 I-iodoamphetamine with special reference to esophageal varices and bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Shirasaki, Keiji; Ishii, Kohdoh; Kokubu, Shigehiro; Shibata, Hisao; Ishii, Katsumi (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine)

    1990-12-01

    Portosystemic shunting was evaluated by portal scintigraphy with transrectally admininistered {sup 123}I-iodoamphetamine (IMP) in 21 patients with liver diseases. IMP was injected in an amount of 111 MBq (3 mCi) into the upper part of the rectum through the catheter. Images of the liver and lungs were monitores for up to 60 minutes with scintillation camera. The subjects were divided into three groups according to the images of the organs: the tracer was accumulated predominantly in the lungs (group A); almost equally accumulated in the both organs (group B); accumulated predominantly in the liver (group C). Advanced liver cirrhosis and IPH with esophageal varices were almost exclusively seen in group A, whereas early stage of liver cirrhosis and other mild hepatic lesions without esophageal varix remainded in group C. Patients of group A showed worse laboratory data than those of group C, including platelet count, serum levels of ch-E and {gamma}-globulin. It is noteworthy that in patients with esophageal bleeding, clear lung images appeared shortly after IMP administration in contrast with extremely delayed visualization of the liver. On the contrary, liver images was demonstrated early in cirrhotic patients without esophageal bleeding. It was coucluded that portal scintigraphy with IMP is useful for the evaluation of portosystemic shunting, especially in esophageal varices. (author).

  11. A meta-analysis of 18FDG-PET–CT, 18FDG-PET, MRI and bone scintigraphy for diagnosis of bone metastases in patients with lung cancer

    International Nuclear Information System (INIS)

    Qu Xinhua; Huang Xiaolu; Yan Weili; Wu Lianming; Dai Kerong

    2012-01-01

    Background and purpose: Lung cancer is the most common cause of cancer related death among both men and women worldwide. The skeleton is the most common site of cancer metastasis. Early detection is crucial for prognosis. To evaluate and compare the capability for bone metastasis assessment of [ 18 F] fluoro-2-D-glucose positron emission tomography with computed tomography ( 18 FDG-PET–CT), [ 18 F] fluoro-2-D-glucose positron emission tomography ( 18 FDG-PET), magnetic resonance imaging (MRI) and bone scintigraphy (BS) in lung cancer patients, a meta-analysis is preformed. Methods: We searched MEDLINE, OVID, EMBASE and the Cochrane Library for studies evaluating diagnosis validity of 18 FDG-PET–CT, 18 FDG-PET, MRI and BS between January 1990 and August 2010. Meta-analysis methods were used to pool sensitivity, specificity, diagnostic odd ratios (DORs) and to construct a summary receiver-operating characteristic curve (SROC). Results: A total of 17 articles (9 18 FDG-PET–CT studies, 9 18 FDG-PET studies, 6 MRI studies and 16 BS studies) that included 2940 patients who fulfilled all of the inclusion criteria were considered for inclusion in the analysis. The pooled sensitivity for the detection of bone metastasis in lung cancer using 18 FDG-PET–CT, 18 FDG-PET, MRI and BS were 0.92 (95% CI, 0.88–0.95), 0.87 (95% CI, 0.81–0.92), 0.77 (95% CI, 0.65–0.87) and 0.86 (95% CI, 0.82–0.89), respectively. The pooled specificity for the detection of bone metastasis from lung cancer using 18 FDG-PET–CT, 18 FDG-PET, MRI and BS were 0.98 (95% CI, 0.97–0.98), 0.94 (95% CI, 0.92–0.96), 0.92 (95% CI, 0.88–0.95), 0.88 (95% CI, 0.86–0.89), respectively. The pooled DORs estimates for 18 FDG-PET–CT 449.17 were significantly higher than for 18 FDG-PET (118.25, P 18 FDG-PET–CT and 18 FDG-PET were better imaging methods for diagnosing bone metastasis from lung cancer than MRI and BS. 18 FDG-PET–CT has higher diagnostic value (sensitivity, specificity and DORs

  12. Synthesis and Antifungal Activity of Novel 3-Caren-5-One Oxime Esters

    Directory of Open Access Journals (Sweden)

    Min Huang

    2017-09-01

    Full Text Available A series of novel 3-caren-5-one oxime esters were designed and synthesized by multi-step reactions in an attempt to develop potent antifungal agents. Two E-Z stereoisomers of the intermediate 3-caren-5-one oxime were separated by column chromatography for the first time. The structures of all the intermediates and target compounds were confirmed by UV-Vis, FTIR, NMR, ESI-MS, and elemental analysis. The antifungal activity of the target compounds was preliminarily evaluated by the in vitro method against Fusarium oxysporum f. sp. cucumerinum, Physalospora piricola, Alternaria solani, Cercospora arachidicola, Gibberella zeae, Rhizoeotnia solani, Bipolaris maydis, and Colleterichum orbicalare at 50 µg/mL. The target compounds exhibited best antifungal activity against P. piricola, in which compounds (Z-4r (R = β-pyridyl, (Z-4q (R = α-thienyl, (E-4f′ (R = p-F Ph, (Z-4i (R = m-Me Ph, (Z-4j (R = p-Me Ph, and (Z-4p (R = α-furyl had inhibition rates of 97.1%, 87.4%, 87.4%, 85.0%, 81.9%, and 77.7%, respectively, showing better antifungal activity than that of the commercial fungicide chlorothanil. Also, compound (Z-4r (R = β-pyridyl displayed remarkable antifungal activity against all the tested fungi, with inhibition rates of 76.7%, 82.7%, 97.1%, 66.3%, 74.7%, 93.9%, 76.7% and 93.3%, respectively, showing better or comparable antifungal activity than that of the commercial fungicide chlorothanil. Besides, the E-Z isomers of the target oxime esters were found to show obvious differences in antifungal activity. These results provide an encouraging framework that could lead to the development of potent novel antifungal agents.

  13. Synthesis and Bioactivities of Novel Pyrazole Oxime Derivatives Containing a 5-Trifluoromethylpyridyl Moiety

    Directory of Open Access Journals (Sweden)

    Hong Dai

    2016-02-01

    Full Text Available In this study, in order to find novel biologically active pyrazole oxime compounds, a series of pyrazole oxime derivatives containing a 5-trifluoromethylpyridyl moiety were synthesized. Preliminary bioassays indicated that most title compounds were found to display good to excellent acaricidal activity against Tetranychus cinnabarinus at a concentration of 200 μg/mL, and some designed compounds still showed excellent acaricidal activity against Tetranychus cinnabarinus at the concentration of 10 μg/mL, especially since the inhibition rates of compounds 8e, 8f, 8l, 8m, 8n, 8p, and 8q were all 100.00%. Interestingly, some target compounds exhibited moderate to good insecticidal activities against Plutella xylostella and Aphis craccivora at a concentration of 200 μg/mL; furthermore, compounds 8e and 8l possessed outstanding insecticidal activities against Plutella xylostella under the concentration of 50 μg/mL.

  14. Use of 67Ga citrate in the diagnosis of lung cancer

    International Nuclear Information System (INIS)

    Bogdasarov, Yu.B.; Zajtseva, T.I.; Gabuniya, R.I.; Abramov, V.F.

    1981-01-01

    A study was of the potentialities of 67 Ga citrate in the diagnosis of lung cancer, in differentiation from benign tumors and chronic inflammatory processes of the lungs. A total of 101 lung cancer patients were examined, of them 64 with central, and 37 with peripheral cancer. The results of radionuclide studies were correlated with those of surgery and with morphological findings. It has been established that in central cancer scintigraphy with 67 Ga citrate gives positive results in 87% of cases, and in peripheral cancer in 89%. This method is of great value for the diagnosis of cancer metastases to the mediastinal lymph nodes. No correlation between the intensity of 67 Ga citrate accumulation in lung tumors and their histological structure has been revealed [ru

  15. Unilateral absence of lung perfusion resulting from endarteritis of the pulmonary artery

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Turini, T.L.

    This case shows endarteritis of left pulmonary artery in the angiographic study with absent perfusion of the left lung in the MAA 131 I scintigraphy. Considerations are made conderning the presumable diagnosis of infection by 'toxocara canis' larval form. The literature review don't point out a similar case. (author) [pt

  16. Scintigraphic and MR perfusion imaging in preoperative evaluation for lung volume reduction surgery. Pilot study results

    International Nuclear Information System (INIS)

    Johkoh, Takeshi; Mueller, N.L.; Kavanagh, P.V

    2000-01-01

    To compare MR perfusion imaging with perfusion scintigraphy in the evaluation of patients with pulmonary emphysema being considered for lung volume reduction surgery. Six patients with pulmonary emphysema and two normal individuals were evaluated by MR perfusion imaging, perfusion scintigraphy, and selective bilateral pulmonary angiography. MR images were obtained with an enhanced fast gradient recalled echo with three-dimensional Fourier transformation technique (efgre 3D) (6.3/1.3; flip angle, 30 deg C; field of view, 45-48 cm; matrix, 256 x 160). The presence or absence of perfusion defects in each segment was evaluated by two independent observers. Using angiography as the gold standard, the sensitivity, specificity, and accuracy of MR perfusion imaging in detecting focal perfusion abnormalities were 90%, 87%, and 89%, respectively, while those of perfusion scintigraphy were 71%, 76%, and 71%, respectively. The diagnostic accuracy of MR perfusion imaging was significantly higher than that of scintigraphy (p<0.001, McNemar test). There was good agreement between two observers for MR perfusion imaging (kappa statistic, 0.66) and only moderate agreement for perfusion scintigraphy (kappa statistic, 0.51). MR perfusion imaging is superior to perfusion scintigraphy in the evaluation of pulmonary parenchymal perfusion in patients with pulmonary emphysema. (author)

  17. Thallium-technetium-subtraction scintigraphy in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Adalet, I.; Hawkins, T.; Clark, F.; Wilkinson, R.

    1994-01-01

    Between 1983 and 1992 thallium-technetium subtraction scintigraphy (TTS) was performed on 74 patients with clinical and biochemical evidence of hyperparathyroidism. Twenty-five of the 53 investigations since 1988 were conducted on patients with renal failure with a suspicion of secondary hyperparathyroidism. In a retrospective study we have evaluated radioisotope scintigraphy for patients with adenoma and for renal failure patients with possible parathyroid hyperplasia. Thirty of 74 patients underwent neck exploration. Scintigraphy detected 17 of 24 parathyroid adenomas (sensitivity 71%). In contrast, in six renal patients who came to operation, scintigraphy localised only 5 of 20 hyperplastic parathyroid glands (sensitivity 25%) and in one renal patient we localised a parathyroid adenoma. A review of the literature shows low detection rates for hyperplasia by TTS to be a common observation. Based on these findings a rational approach is offered for parathyroid localisation in renal patients prior to neck exploration. (orig.)

  18. RI scintigraphy in myasthenia gravis

    International Nuclear Information System (INIS)

    Kuroda, Yoshikazu; Miyamoto, Mariko; Maki, Masako; Yamazaki, Toshiro.

    1982-01-01

    35 cases of myasthenia gravis were studied with RI scintigraphy. 67 Ga-citrate was used in 34 patients and 76 Se-selenomethionine in 5 patients for thymus scintigraphy. RI scintigram was negative in non-tumorous thymus, regardless of the severity of illness and it was positive in seven of nine patients with thymomas. RI accumulation in thymus was found both in benign and malignant thymomas. RI seems to accumulated in lymphocytic and mixed thymus more than epithelial type. (author)

  19. Radionuclide bone scintigraphy in pediatric orthopedics

    International Nuclear Information System (INIS)

    Conway, J.J.

    1986-01-01

    Radionuclide bone scintigraphy is highly sensitive and specific for diagnosing the musculoskeletal disorders of childhood. Conditions such as neonatal osteomyelitis, septic arthritis, diskitis of childhood, Legg-Calve-Perthes disease, the osteochondroses, the toddler's fracture, sports injuries, spondylolysis, myositis ossificians, and reflex sympathetic dystrophy are readily defined. High-quality state-of-the-art scintigraphy is essential in infants and young children. 64 references

  20. Noninvasive staging of lung cancer. Indications and limitations of gallium-67 citrate imaging

    International Nuclear Information System (INIS)

    Bekerman, C.; Caride, V.J.; Hoffer, P.B.; Boles, C.A.

    1990-01-01

    The results of evaluation of the hila and mediastinum with 67Ga scans are contradictory, as are the recommendations by different investigators on the use of 67Ga scintigraphy in the clinical evaluation of patients with primary lung carcinoma. Nevertheless, the economy and logistic simplicity of evaluating local and distant metastases with a single imaging procedure are attractive, especially because the symptoms may not enable the physician to make a correct identification of the organ systems affected by metastases. Neumann and Hoffer state that at present conventional Ga-67 scanning techniques cannot be recommended for preoperative staging of mediastinal lymph node metastases in lung cancer patients. According to Waxman, 67Ga scintigraphy, relative to other imaging modalities, is a sensitive indicator of hilar spread of a tumor. However, because of the normally high background activity within the sternum and spine, mediastinal abnormalities may be poorly detected. Since most pulmonary tumors metastasize via regional nodes to the pulmonary hilum and then to the mediastinum, the high sensitivity for the detection of pulmonary hilar abnormalities and the high specificity for detection of mediastinal lesions suggest that gallium scintigraphy is a valuable adjunctive test when used appropriately. The results obtained locally are probably the best guide for individual physicians in the selection of diagnostic tests for their patients. Gallium scans may thus be helpful in the clinical evaluation of patients with lung cancer. Although gallium scans identify mediastinal node involvement, there is considerable controversy over the relationship between the sensitivity and specificity of the method. By detecting distant extrathoracic metastases, the 67Ga scan may identify a small group of patients who can be spared a needless operation. 92 references

  1. Using 99mTc-DTPA radioaerosol inhalation lung scan as compared with computed tomography to detect lung injury in blunt chest trauma

    International Nuclear Information System (INIS)

    Esme, H.; Kaya, E.; Solak, O.; Yavuz, Y.; Yurumez, Y.; Sezer, M.

    2007-01-01

    Detection of pulmonary contusion in patients with blunt chest trauma is very important so as to commence therapy immediately to avoid irreversible damage. The purpose of our study was to evaluate the efficacy of technetium-99m diethylene triamine penta-acetic acid ( 99m Tc-DTPA) aerosol inhalation lung scintigraphy in comparison with chest computed tomography (CT) in the diagnosis of pulmonary contusion at acute blunt chest trauma. Twenty-nine patients with isolated blunt chest trauma were referred to the emergency department of our hospital, and nine healthy people participated in this study. Sixteen patients who had pulmonary contusion on CT scans were referred to as group 1, and 13 patients who had normal CT scans as group 2. Nine healthy people comprised a control group. 99m Tc-DTPA aerosol inhalation lung scintigraphy was performed on the first day in all patients. The mean half time (T 1/2 ) and penetration index values of 99m Tc-DTPA clearance were significantly lower in groups 1 and 2 compared with the control group. Among the three groups, there were no significant differences in arterial blood gas analysis except for PO 2 . The mean T 1/2 value of 99m Tc-DTPA clearance did correlate with PO 2 values but not with pH, PCO 2 , or HCO 3 values. 99m Tc-DTPA radioaerosol inhalation lung imaging may serve as a useful adjunct and supportive method to chest CT scanning for detecting mild pulmonary contusion. (author)

  2. RI scintigraphy in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Yoshikazu; Miyamoto, Mariko (Tokyo Metropolitan Fuchu Hospital (Japan)); Maki, Masako; Yamazaki, Toshiro

    1982-10-01

    35 cases of myasthenia gravis were studied with RI scintigraphy. /sup 67/Ga-citrate was used in 34 patients and /sup 76/Se-selenomethionine in 5 patients for thymus scintigraphy. RI scintigram was negative in non-tumorous thymus, regardless of the severity of illness and it was positive in seven of nine patients with thymomas. RI accumulation in thymus was found both in benign and malignant thymomas. RI seems to accumulated in lymphocytic and mixed thymus more than epithelial type.

  3. The value of scintigraphy in skeleton diagnostics

    International Nuclear Information System (INIS)

    Wickenhauser, J.

    1976-01-01

    The complex topic of diagnostics of the numerous skeleton diseases was enriched by nuclear medicine, for it is now possible to complete the static picture of morphologic changes resulting from radiologic examinations by its functional component, shown in scintigraphy. This shows that maximal information can only be obtained if the results of skeleton scintigraphy are, according to their importance, integrated into the total picture of the diagnostical decision procedure the centre of which is taken by radiology as was always the case. Because of the different results they lead to, none of the methods can be replaced by another, but they can only complete one another. For the reasons mentioned, the isolated use of skeleton scintigraphy, as it is usual in many places, does not seem not purposeful. Using 8 cases, the author tried to show the problems of skeleton scintigraphy and its position in the diagnostical decision procedure in osteology. (orig.) [de

  4. Utility of 67Ga scintigraphy and bronchial washings in the diagnosis and treatment of Pneumocystis carinii pneumonia in patients with the acquired immune deficiency syndrome

    International Nuclear Information System (INIS)

    Tuazon, C.U.; Delaney, M.D.; Simon, G.L.; Witorsch, P.; Varma, V.M.

    1985-01-01

    Twenty patients with the acquired immune deficiency syndrome (AIDS) and suspected Pneumocystis carinii pneumonia were evaluated by 67 Ga scintigraphy and fiberoptic bronchoscopy for initial diagnosis and response to therapy. Lung uptake of 67 Ga was demonstrated in 100% of AIDS patients with P. carinii pneumonia, including those with subclinical infection. Fiberoptic bronchoscopy identified P. carinii in the bronchial washings of 100% of cases (19 patients), whereas only 13 of 16 (81%) patients had P. carinii in lung tissue obtained by transbronchial biopsy. Repeat fiberoptic bronchoscopy was performed in 16 of 20 patients. After 2 to 4 wk of therapy, P. carinii was identified in bronchial washings in 8 of 16 (50%) patients and in transbronchial biopsy in 1 of 10 (10%) patients examined. Bronchial washing has a higher yield than transbronchial biopsy in demonstrating P. carinii in patients with AIDS and may evolve as the procedure of choice in such patients. Based on the clinical course and results of 67 Ga scintigraphy and fiberoptic bronchoscopy in AIDS patients with P. carinii pneumonia, optimal therapy may require at least 3 wk of treatment

  5. Isotopic scintigraphy in kidney grafting

    International Nuclear Information System (INIS)

    Renfro, Richard.

    1976-01-01

    Isotopic explorations of kidney transplants were performed on sixty-six patients. Three scintigraphic techniques were used: labelled ferrous ascorbate scintigraphy, sequential 99m technetium DTPA scintigraphy and the 131 I hippuran nephrogram. The aim of this study is to analyse the results obtained under different pathological circumstances affecting the transplant, to discuss the advantages of the techniques and to propose a working procedure. The most reliable and accurate technique is the 131 I hippuran nephrogram combined with sequential 99mTc DTPA, by which renal vascularisation may be judged labelled ferrous ascorbate on the other hand is too insensitive. Although the information supplied is mostly contained in the scintigraphic images, the nephrographic curves and the blood radioactivity decay time and rad V/rad R ratio measurements are very helpful in the early diagnosis and differential diagnosis of complications affecting the transplant. The proper use of isotopic scintigraphy in kidney grafting should provide optimum conditions for better survival of the transplant at minimum risk to the patient [fr

  6. Bone scintigraphy in psoriasis

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, K.; Thiers, G.; Eissner, D.; Holzmann, H.

    1980-08-01

    Since 1973 bone scintigraphy using sup(99m)Tc-phosphate-complexes was carried out in 382 patients with psoriasis. For comparison with the results of nuclear medicine, roentgenologic and clinical findings a group af 121 patients with psoriasis aged between 11 and 74 years was compared to a group of 42 patients aged between 20 and 49 years without roentgenologic and clinical signs of psoriasis arthritis. We found by means of isotope investigation that an essentially greater part of the bones adjacent to the joints was involved than was expected according to X-ray and clinical findings. In addition, in 205 patients with psoriasis whole-body scintigraphy, using sup(99m)Tc-MDP, was carried out since 1977/78. In 17 patients we found an increased accumulation of activity in the region of extraarticular structures of the skull as well as of the skeletal thorax. According to these results we conclude that in addition to the clinically and roentgenologically defined psoriatic arthritis in patients with psoriasis an osteopathy may exist, which can only be demonstrated by skeletal scintigraphy and which is localized in bones adjacent to the joints but can also be demonstrated in the region of extraarticular bones.

  7. A comparison of the economics of xenon 127, xenon 133 and krypton 81m for routine ventilation imaging of the lungs

    International Nuclear Information System (INIS)

    Nimmo, M.J.; Merrick, M.V.; Millar, A.M.

    1985-01-01

    The authors have compared the cost of providing routine lung ventilation scintigraphy using 127 Xe with other radioactive gases in 100 patients. The physical properties of 127 Xe permit a logical imaging sequence where a ventilation study is only carried out if indicated by perfusion scintigraphy which is performed first. With 133 Xe, all patients must be ventilated prospectively, or a preselection carried out based on radiographic appearances at the time of imaging. This results in a greater number of ventilation studies than with 127 Xe. Despite the greater cost per study of 127 Xe, the overall cost of providing a routine diagnostic service with this gas is no more than that of using 133 Xe in selected patients. The cost of ventilating all patients prospectively with 133 Xe is considerably greater than using 127 Xe only when indicated by abnormal perfusion images. If ventilation imaging is to be available at all times, either isotope of xenon costs very much less than 81 Krsup(m). It is concluded that 127 Xe is the radiopharmaceutical of choice for routine lung ventilation scintigraphy. (author)

  8. Somatostatin receptor scintigraphy on thyroid carcinoma

    International Nuclear Information System (INIS)

    Pan Weimin; Tan Tianzhi

    2004-01-01

    Purpose: To study the diagnostic value and clinical method of somatostatin receptor scintigraphy on thyroid carcinoma using 99 Tc m -RC-160 labeled with direct method as scintigraphy reagent; Methods: Somatostatin receptor scintigraphy (SRS) were performed on 25 patients with thyroid carcinoma, using 99 Tc m -RC-160 labeled with direct method as scintigraphy reagent, controlling with 131 I- whole- body- imaging(1312 -WBI). Results: Of 4 patients with MTC (medullary thyroid carcinoma), positive metastasis and primary tumour were detected on 3 patients by SRS, negative results were obtained by 131 I-WBI, the positive detective rate by SRS is 3/4; of 12 patients with PTC (papillary thyroid carcinoma), positive metastasis and primary tumour were detected on 2 patients by SRS or 131 I-WBI,1 of which only by SRS, while negative results were obtained by 131 I- WBI, the positive detective rate by SRS is 3/12; of 8 patients with FTC(follicular thyroid carcinoma), positive metastasis and primary tumour were detected on 1 patients by SRS or 131 I-WBI, and 2 positive results were obtained only by SRS, while negative by 131 I-WBI, the positive detective rate by SRS is 3/8; of 1 patients with HCC (hurthle cell carcinoma ), positive metastasis and primary tumour were detected by SRS, while negative by 131 I-WBI; Conclusions: SRS using 99 Tc m -RC-160 labeled with direct method as scintigraphy reagent has high diagnostic value on thyroid carcinoma, especially on MTC and HCC. (authors)

  9. Radionuclide bone scintigraphy in pediatric orthopedics

    Energy Technology Data Exchange (ETDEWEB)

    Conway, J.J.

    1986-12-01

    Radionuclide bone scintigraphy is highly sensitive and specific for diagnosing the musculoskeletal disorders of childhood. Conditions such as neonatal osteomyelitis, septic arthritis, diskitis of childhood, Legg-Calve-Perthes disease, the osteochondroses, the toddler's fracture, sports injuries, spondylolysis, myositis ossificians, and reflex sympathetic dystrophy are readily defined. High-quality state-of-the-art scintigraphy is essential in infants and young children. 64 references.

  10. Dual-phase 99mTc-MIBI scintigraphy with delayed neck and thorax SPECT/CT and bone scintigraphy in patients with primary hyperparathyroidism. Correlation with clinical or pathological variables

    International Nuclear Information System (INIS)

    Qiu, Zhongling; Shen, Chentian; Zhu, Ruisen; Luo, Quanyong; Wu, Bo

    2014-01-01

    The purpose of this study was to assess the relationship between 99m Tc-MIBI and 99m Tc-MDP bone scintigraphy and clinical or pathological variables, including preoperative serum PTH levels and tumor diameter, in patients with newly diagnosed PHPT. Dual phase 99m Tc-MIBI planar scintigraphy was performed in 244 patients with PHPT. Of these patients, 155 underwent 99m Tc-MDP bone scintigraphy to detect bone changes before parathyroidectomy. Factors influencing 99m Tc-MIBI scintigraphy and 99m Tc-MDP bone scintigraphy detection rate were assessed using univariate and multivariate logistic regression analysis; optimal cutoff values for predicting positive 99m Tc-MIBI and 99m Tc-MDP bone scintigraphy were evaluated using ROC analysis. Among 244 patients, 174 (71.31%) patients with 181 foci had a positive 99m Tc-MIBI planar scintigraphy; delayed neck and thorax SPECT/CT could identify and locate the 99m Tc-MIBI lesions but could not find more lesions than planar scintigraphy. 70 (28.69%) patients had a negative 99m Tc-MIBI planar scintigraphy. Tumor diameter, serum PTH level and symptoms were statistically significant predictive factors in predicting positive 9m Tc-MIBI scintigraphy both univariate and multivariate logistic regression analyses. The optimal thresholds for tumor diameter and serum PTH by ROC analysis were 1.03 cm and 127.60 ng/L, respectively. Among 155 patients with bone scintigraphy, 99m Tc-MDP bone scintigraphy showed positive finding in 80 (51.61%) patients and negative finding in 75 patients. Univariate logistic regression analysis showed that patient age, sex, tumor diameter and PTH level (≥150 ng/L) were statistically significant in predicting positive 99m Tc-MDP bone scintigraphy. Multivariate logistic regression analysis showed both tumor diameter and PTH ≥150 ng/L were statistically significant in predicting positive 99m Tc-MDP bone scintigraphy. The optimal thresholds for tumor diameter and serum PTH by ROC analysis were 1.96 cm and 163

  11. Procedure guideline for thyroid scintigraphy (version 3)

    International Nuclear Information System (INIS)

    Dietlein, M.; Schicha, H.; Eschner, W.; Deutsche Gesellschaft fuer Medizinische Physik; Koeln Univ.; Leisner, B.; Allgemeines Krankenhaus St. Georg, Hamburg; Reiners, C.; Wuerzburg Univ.

    2007-01-01

    The version 3 of the procedure guideline for thyroid scintigraphy is an update of the procedure guideline previously published in 2003. The interpretation of the scintigraphy requires the knowledge of the patients' history, the palpation of the neck, the laboratory parameters and of the sonography. The interpretation of the technetium-99m uptake requires the knowledge of the TSH-level. As a consequence of the improved alimentary iodine supply the 99m Tc-uptake has decreased; 100 000 counts per scintigraphy should be acquired. For this, an imaging time of 10 minutes is generally needed using a high resolution collimator for thyroid imaging. (orig.)

  12. The effect of the conditions of amidoximation on the adsorptive characteristics of amide oxime resin for uranium recovery from seawater

    International Nuclear Information System (INIS)

    Hori, Takahiro; Furusaki, Shintaro; Sugo, Takanobu; Okamoto, Jiro.

    1987-01-01

    A hollow-fiber type chelating resin containing the amide oxime group for the recovery of uranium from seawater was synthesized by radiation-induced graft polymerization. The effect of the conditions of amidoximation on the amount and/or distribution of the functional groups and on the durability to the recycle adsorption was investigated. The amount of adsorbed copper on the resin increased with the reaction time of the amidoximation, but that of adsorbed hydrochloric acid gradually decreased after reaching the maximum. From the results of elemental analysis, infrared adsorption spectra, visible light and ultraviolet adsorption spectra and the observation of coloration of the resin by alkaline treatment, the amidoximation was found to be a consecutive reaction. The results also suggested that, after the introduction of the amide oxime group, the acidic amide, hydroxamic acid and/or cyclic functional groups were formed. From the measurement of the distribution of adsorbed copper by X-ray microanalyzer, it was confirmed that the amidoximation occured uniformly across the resin. An experiment was carried out on the recycle adsorption of the amide oxime resin using natural seawater, and the sufficient durability was recognized for the case that the resin was taken out from the hydroxylamine solution at the time when the amount of adsorbed hydrochloric acid reached the maximum. In this case the resin contained the largest amount of the amide oxime group and least amount of the by-products formed from the secondary reactions. (author)

  13. Clinical experience of [sup 123]I-IMP scintigraphy in detecting vertebral bone metastases of hepatocellular carcinoma. A comparison with bone scintigraphy with [sup 99m]Tc-MDP

    Energy Technology Data Exchange (ETDEWEB)

    Suto, Y. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Iwamiya, T. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Tanigawa, N. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Shabana, M. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Ohta, Y. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan))

    1994-03-01

    [sup 123]I-IMP and bone scintigraphy with [sup 99m]Tc-MDP were consecutively performed in patients with vertebral bone metastases from hepatocellular carcinoma and lumbar spondylosis deformans in a 7-day interval or shorter. The intensity of uptake was compared. Eighteen of the 20 metastatic lesions (90%) were classified as increased uptake areas in [sup 123]I-IMP scintigraphy. MDP-scintigraphy disclosed 16 metastatic lesions (80%), 9 as ''hot'' lesions (56%) and 7 as ''cold'' lesions (44%). [sup 123]I-IMP scintigraphy was negative in all 12 lesions of lumbar spondylosis deformans. Compared to MDP-scintigraphy, [sup 123]I-IMP scintigraphy was more sensitive in detecting vertebral bone metastases of hepatocellular carcinoma with smaller rates of false-positive and false-negative findings. (orig./MG).

  14. Chondromalacia patellae: Bone scintigraphy correlated with arthroscopic findings

    International Nuclear Information System (INIS)

    Kohn, H.S.; Guten, G.N.; Collier, B.D.; Veluvolu, P.; Whalen, J.P.

    1987-01-01

    Fifty adult sports medicine patients with anterior knee pain and other clinical findings of chondromalacia patellae unresponsive to more than 3 months of conservative therapy were evaluated with bone scintigraphy with subsequent arthroscopic correlation. There was significant correlation (Sperman rank correlation = .545, P < .001) between the intensity of increased patellar scintigraphic activity and the Metcalf grade of chondromalacia seen at arthroscopy. Bone scintigraphy also disclosed clinically unsuspected torn menisci. Bone scintigraphy contributes to accurate diagnostic evaluation and appropriate surgical planning for adult sports medicine patients with chronic anterior knee pain

  15. Clinical course of cor pulmonale investigated after an interval of one year by thallium-201 myocardial SPECT scintigraphy

    International Nuclear Information System (INIS)

    Yamaoka, Shimpachi; Nishimura, Kouichi; Kuno, Kenshi; Yonekura, Yoshiharu; Koide, Harutoshi.

    1988-01-01

    Cor pulmonale was evaluated in 13 patients with chronic lung disease by thallium-201 myocardial SPECT scintigraphy together with pulmonary function tests and right heart catheterization. One year later, we performed this scintigraphy again to investigate the clinical course of the cor pulmonale. In 6 of 13 patients with respiratory failure (Pao 2 less than 60 Torr), a remarkable progression in cor pulmonale was noted after one year, despite outpatient oxygen therapy. If the patients were admitted because of acute exacerbation of respiratory failure, the cor pulmonale was found to have worsened. In contrast, patients with acute exacerbation due to respiratory infection or causes other than respiratory failure, showed little change in cor pulmonale. Although patients with a marked progression of cor pulmonale tended to have poor pulmonary function data and elevated pulmonary arterial pressure, the clinical course of cor pulmonale could not be predicted from the initial pulmonary function tests or right heart catheterization. (author)

  16. Radiography and bone scintigraphy in bone marrow transplant multiple myeloma patients

    International Nuclear Information System (INIS)

    Aagren, B.; Aspelin, P.

    1997-01-01

    Purpose: To compare conventional radiography and bone scintigraphy in relation to clinical outcome in bone marrow transplant multiple myeloma patients. Material and Methods: A total of 70 radiographies and 70 bone scintigraphies were compared in 35 patients. Results: The skull, the extremities, the iliac and public bones were better assessed with radiography. For new vertebral lesions and for lesions in the ribs and sternum, bone scintigraphy proved superior. For the sacrum, the methods were equal. When bone scintigraphy was used as a complement to radiography, 4% more pathological sites were found. No patient had both a normal radiography and a pathological bone scintigraphy, but 5 patients had both a normal bone scintigraphy and a pathological radiography. The results of the radiological examinations did not always correlate with the clinician's grading of the patient's disease. The radiological examinations had no prognostic value for the 7 patients examined on several occasions. Conclusion: The ability of conventional radiography and bone scintigraphy to disclose myeloma lesions varies, depending on location and size of the lesions. Radiography should remain the primary examination modality also for bone marrow transplant multiple myeloma patients. Bone scintigraphy can severe as a complement for investigating unexplained pain, e.g. caused by lesions in vertebrae or ribs. (orig.)

  17. Diagnostic approach to reflex sympathetic dystrophy after fracture: radiography or bone scintigraphy?

    International Nuclear Information System (INIS)

    Todorovic-Tirnanic, M.; Obradovic, V.; Han, R.; Goldner, B.; Stankovic, D.; Sekulic, D.; Lazic, T.; Djordjevic, B.

    1995-01-01

    The aim of this paper was to compare the value of bone scintigraphy and radiography in the early diagnosis of post-fracture reflex sympathetic dystrophy (RSD). Thirty-seven adult patients with post-fracture RSD (28 in the first and nine in the second clinical stage of RSD), as well as seven patients with fracture but without RSD (control group), were investigated by radiography and bone scintigraphy. All of them were immobilized (duration of immobilization: 4-22 weeks). In 21 persons three phase bone scintigraphy was performed. The best distinction between the control group and the RSD patients was achieved by delayed bone scintigrams. The sensitivity (97%), positive predictive value (97%) and accuracy (95%) of delayed bone scintigraphy were very high compared to the values for radiography, which were 73%, 90% and 70% respectively. Bone scintigraphy also displayed higher specificity (86%) and negative predictive value (86%) than radiography (57% and 29% respectively). In the first clinical stage the difference between the accuracy of bone scintigraphy (97%) and radiography (63%) was greater than for the whole group. In the second stage of RSD the accuracy of bone scintigraphy (86%) and radiography (81%) was similar. Three-phase bone scintigraphy is not necessary for the diagnosis of post-fracture RSD: it is sufficient to perform delayed bone scintigraphy. It is concluded that bone scintigraphy is to be preferred to radiography for the early diagnosis of post-fracture RSD in the first clinical stage. In the second stage the diagnostic capabilities of bone scintigraphy and radiography are more comparable. (orig.)

  18. Evaluation of pN factors in patients with primary lung cancer by using perfusion, inhalation and ventilation studies

    International Nuclear Information System (INIS)

    Tamai, Toyosato; Tanabe, Masatada; Satoh, Katashi

    1987-01-01

    The interpretation of scintigraphic patterns and the role of pathophysiological mechanisms in patients with primary lung cancer were investigated. To determine the relative roles of perfusion, inhalation and ventilation scintigraphy, the relationship between the count ratio of the affected side to the healthy side and the post-surgical histological lymph nodes factors were observed in this study. These scintigraphic count ratio's in patients with primary lung cancer did not reflect the pN factors except in the perfusion study in patients with hilar primary lung cancer. (author)

  19. Pulmonary imaging techniques in the diagnosis of occupational interstitial lung disease

    International Nuclear Information System (INIS)

    Leonard, J.F.; Templeton, P.A.

    1992-01-01

    The chest radiograph is extensively used in evaluating workers at risk for developing occupational lung disease. Other pulmonary imaging techniques used in conjunction with the initial chest radiograph include conventional computed tomography, high resolution computed tomography, and gallium scintigraphy. This chapter evaluates the use of these techniques and their appropriate applications in the pneumoconioses, hypersensitivity pneumonitis, berylliosis, and hard metal diseases.65 references

  20. Nuclear medicine pulmonary diagnosis; Nuklearmedizinische Diagnostik der Lunge

    Energy Technology Data Exchange (ETDEWEB)

    Schuemichen, C. [Rostock Univ. (Germany). Radiologische Klinik und Poliklinik

    2000-10-01

    Scintigraphic recording of regional ventilation and perfusion with {sup 99m}Tc-Aerosol and {sup 99m}Tc-MAA remain in the foreground of nuclear medicine pulmonary diagnostics. The most important indication for ventilation scintigraphy is the prediction of postoperative pulmonary function, which is still performed in many hospitals with perfusion scintigraphy, and with which, in turn, intrapulmonary right-left shunts can be simply and also semiquantitatively recorded. Combined ventilation/perfusion scintigraphy offers a very high degree of sensitivity in the proof of acute pulmonary embolism, is therefore exceptionally well suited for exclusion diagnostics, while specificity compared to pulmonary angiography and spiral CT still needs some clarification. The self-cleaning mechanism of the lung can be quantitatively examined using mucociliary and resorptive clearance. The clinical areas of application are limited for methodical reasons. Primary diagnostics of bronchial carcinoma and dignity differentiation of solitary pulmonary nodules, preferably with {sup 18}F-FDG PET are gaining steadily in importance. (orig.) [German] Im Vordergrund der nuklearmedizinischen Lungendiagnostik steht nach wie vor die szintigraphische Abbildung der regionalen Ventilation und Perfusion mit {sup 99m}Tc-Aerosol und {sup 99m}Tc-MAA. Wichtigste Indikation fuer die Ventilationsszintigraphie ist die Voraussage der postoperativen Lungenfunktion, die vielerorts noch mit der Perfusionsszintigraphie durchgefuehrt wird, mit der sich wiederum intrapulmonale Rechts-links-Shunts einfach und auch semiquantitativ erfassen lassen. Die kombinierte Ventilations-/Perfusionsszintigraphie bietet ein Hoechstmass an Sensitivitaet beim Nachweis der akuten Lungenembolie, ist deshalb fuer die Ausschlussdiagnostik hervorragend geeignet, die Spezifitaet im Vergleich zur Pulmonalisangiographie und Spiral-CT ist weiterhin klaerungsbeduerftig. Die Selbstreinigungsmechanismen der Lunge lassen sich mit der mukoziliaeren

  1. Bone scintigraphy in psoriasis

    International Nuclear Information System (INIS)

    Hahn, K.; Thiers, G.; Eissner, D.; Holzmann, H.; Frankfurt Univ.

    1980-01-01

    Since 1973 bone scintigraphy using sup(99m)Tc-phosphate-complexes was carried out in 382 patients with psoriasis. For comparison with the results of nuclear medicine, roentgenologic and clinical findings a group af 121 patients with psoriasis aged between 11 and 74 years was compared to a group of 42 patients aged between 20 and 49 years without roentgenologic and clinical signs of psoriasis arthritis. We found by means of isotope investigation that an essentially greater part of the bones adjacent to the joints was involved than was expected according to X-ray and clinical findings. In addition, in 205 patients with psoriasis whole-body scintigraphy, using sup(99m)Tc-MDP, was carried out since 1977/78. In 17 patients we found an increased accumulation of activity in the region of extraarticular structures of the skull as well as of the skeletal thorax. According to these results we conclude that in addition to the clinically and roentgenologically defined psoriatic arthritis in patients with psoriasis an osteopathy may exist, which can only be demonstrated by skeletal scintigraphy and which is localized in bones adjacent to the joints but can also be demonstrated in the region of extraarticular bones. (orig.) [de

  2. Assessment of hepatic functional reserve for hepatic resection using 99mTc-PMT scintigraphy in comparison with 99mTc-GSA scintigraphy

    International Nuclear Information System (INIS)

    Sakuma, Atsushi

    2000-01-01

    99m Tc-diethylenetriamine-pentaacetic acid-galactosyl human serum albumin( 99m Tc-GSA) scintigraphy has been reported as a useful study of hepatic functional reserve recently. We have performed 99m Tc-N-pyridoxyl-5-methyl-tryptophan( 99m Tc-PMT) and 99m Tc-GSA preoperatively for evaluation of hepatic functional reserve and compared the usefulness of those scintigraphy study. Twenty-four patients who were the candidates of hepatic resection underwent 99m Tc-PMT scintigraphy preoperatively. Hepatic blood flow coefficient (K value), the amount of hepatic blood flow (HBF), and the ratio of portal blood flow (PVR) were computed. 99m Tc-GSA scintigraphy was also performed within two weeks of the 99m Tc-PMT scintigraphy, and the ratio of disappearance (HH 15 ) and the hepatic uptake ratio (LHL 15 ) were computed. The relationship between K value, HBF, PVR, HH 15 and LHL 15 was analyzed. Their correlation with other liver function tests was also examined. K value and HBF did not show statistically significant correlations with HH 15 and LHL 15 , PVR correlated statistically significantly HH 15 and LHL 15 . K value correlated with the preoperative values of cholinesterase, Fischer ratio, γ-globulin, ICGR 15 , albumin, and platelet count. There was a statistically significant correlation between LHL 15 and the value of cholinesterase, γ-globulin, platelet count, and Fischer ratio. When the liver resection of subsegmentectomy or more was indicated in 10 patients, nine patients had LHL 15 value less than 0.9 which delineated possibility of poor prognosis. However, judging from K value and HBF, liver resection was considered feasible and it was all successfully performed, resulting in good prognosis. From this study, it is suspected that 99m Tc-GSA scintigraphy reflect the severity of liver fibrosis and the amount of portal blood flows, and 99m Tc-PMT scintigraphy reflect the hepatic blood flow and ability of protein synthesis. It was proved that 99m Tc-PMT scintigraphy is

  3. Biodistribution and scintigraphy of iodine-131-iododeoxyadenosine in rats bearing breast cancer

    International Nuclear Information System (INIS)

    Kim, Seon Gu; Kim, Chang Guhn; Lee, Kang Mo

    1998-01-01

    I-131 labeled (2'-deoxy-2'-iodo-β-D-arabinofuranosyl) adenine (IAD) may be involved in DNA synthesis during active proliferation of tumor cells. We conducted this study to find out the biodistribution of IAD and it's feasibility for scintigraphic tumor imaging. Tosyl acetyl-adenosine was dissolved in acetonitrile, and I-131-NaI was added and heated to synthesize IAD. Female Fisher 344 rats inoculated with breast tumor cells were injected with 0.27 MBq of IAD. Rats were sacrificed at 0.5, 1, 2, 4, 24h and the % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy, rats bearing breast cancer were administered with 1.11 MBq of IAD and imaging was performed after 2 and 24h. Then, rat body was fixed and microtomized slice was placed on radiographic film for autoradiography. %ID/g of tumor was 0.74 (0.5h), 0.73 (1h), 0.55 (2h), 0.38 (4h), and 0.05 (24h), respectively. At 1h after injection, %ID/g of tumor was higher than that of heart (0.51). However, %ID/g of tumor was lower than blood (1.06), lung (0.77), and thyroid (177.71). At 4h, %ID/g of tumor in comparison with other tissue did not change. Tumor contrast expressed by tumor to blood ratio was 0.69 and tumor to muscle ratio was 5.11 at 1h. However, these ratios did not improve through 24h. On autoradiogram and scintigraphy at 2 and 24 hour, the tumor was well visualized. This results suggest that IAD may have a potential for tumor scintigraphy. However, further work is needed to improve localization in tumor tissue

  4. Optimizing renal DMSA-scintigraphy with 7-pinhole collimator

    International Nuclear Information System (INIS)

    Botsch, H.; Pottmeyer, A.; Savaser, A.; Lochner, B.; Felix, R.

    1982-01-01

    Multiple pinhole emission tomographic imaging techniques are currently being applied to imaging of organs of a limited size. The purpose of this study was to evaluate the feasibility of this technique in kidney imaging with Tcsup(99m)-DMSA. A 7-pinhole collimator having 4.5 mm. pinhole apertures was used in conjunction with a widefield camera. Left and right kidney were imaged separately. Twelve small renal cysts with a diameter of 1 to 3.5 cm. verified by US or CAT were investigated by 7-pinhole and planar scintigraphy. Eight of 12 renal cysts were identified by 7-pinhole scintigraphy whereas only one cyst was seen by planar scintigraphy. The borderline of cysts detection was 1.5 cm. in 7-pinhole tomography. Basing on these comparative studies and experiences on many patient investigations it seems reasonable to perform renal scintigraphy with 7-pinhole tomography in a routine manner. (orig.)

  5. Synthesis and 5α-Reductase Inhibitory Activity of C21 Steroids Having 1,4-diene or 4,6-diene 20-ones and 4-Azasteroid 20-Oximes

    Directory of Open Access Journals (Sweden)

    Eunsook Ma

    2011-12-01

    Full Text Available The synthesis and evaluation of 5α-reductase inhibitory activity of some 4-azasteroid-20-ones and 20-oximes and 3β-hydroxy-, 3β-acetoxy-, or epoxy-substituted C21 steroidal 20-ones and 20-oximes having double bonds in the A and/or B ring are described. Inhibitory activity of synthesized compounds was assessed using 5α-reductase enzyme and [1,2,6,7-3H]testosterone as substrate. All synthesized compounds were less active than finasteride (IC50: 1.2 nM. Three 4-azasteroid-2-oximes (compounds 4, 6 and 8 showed good inhibitory activity (IC50: 26, 10 and 11 nM and were more active than corresponding 4-azasteroid 20-ones (compounds 3, 5 and 7. 3β-Hydroxy-, 3β-acetoxy- and 1α,2α-, 5α,6α- or 6α,7α-epoxysteroid-20-one and -20-oxime derivatives having double bonds in the A and/or B ring showed no inhibition of 5α-reductase enzyme.

  6. Precision cut lung slices as test system for candidate therapeutics in organophosphate poisoning.

    Science.gov (United States)

    Herbert, Julia; Thiermann, Horst; Worek, Franz; Wille, Timo

    2017-08-15

    Standard therapeutic options in organophosphate (OP) poisoning are limited to the administration of atropine and oximes, a regimen often lacking in efficacy and applicability. Treatment alternatives are needed, preferably covering a broad spectrum of OP intoxications. Although recent research yielded several promising compounds, e.g. bioscavengers, modulators of the muscarinic acetylcholine (ACh) receptor or bispyridinium non-oximes, these substances still need further evaluation, especially regarding effects on the potentially lethal respiratory symptoms of OP poisoning. Aim of this study was the development of an applicable and easy method to test the therapeutic efficiency of such substances. For this purpose, airway responsiveness in viable precision cut lung slices (PCLS) from rats was analysed. We showed that ACh-induced airway contractions were spontaneously reversible in non-poisoned PCLS, whereas in OP poisoned PCLS, contractions were irreversible. This effect could be antagonized by addition of the standard therapeutic atropine, thereby presenting a clear indication for treatment efficiency. Now, candidate therapeutic compounds can be evaluated, based on their ability to counteract the irreversible airway contraction in OP poisoned PCLS. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Abdominal scintigraphy using 99mTc-HMPAO-labelled leucocytes in patients with seronegative spondylarthropathies without clinical evidence of inflammatory bowel disease

    International Nuclear Information System (INIS)

    Alonso, J.C.; Lopez-Longo, F.J.; Lampreave, J.L.; Gonzalez, C.M.; Vegazo, O.; Carreno, L.; Almoguera, I.

    1996-01-01

    Abdominal scintigraphy with technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO)-labelled leucocytes is an excellent tool for evaluating disease extent and activity of intestinal lesions in patients with inflammatory bowel disease (IBD). In some cases of seronegative spondylarthropathies (SSp), IBD may remain subclinical. The aim of this study was to evaluate the presence of positive abdominal scintigraphy in patients with SSp and without clinical symptoms or signs of IBD. To this end we studied 32 patients with active SSp (European Spondylarthropathy Study Group 1991 criteria) without clinical evidence of IBD (eight had ankylosing spondylitis, four psoriatic arthritis, three reactive arthritis an 17 undifferentiated SSp) and 11 controls without SSp. All SSp and control patients received similar doses of non-steroidal anti-inflammatory drugs (NSAIDs). Abdominal scintigraphic images were obtained at 30 and 120 min after re-injection of 99m Tc-HMPAO-labelled leucocytes. The 99m Tc-HMPAO-labelled leucocyte scan was positive in 17 patients with SSp (53.1%) (six with ankylosing spondylitis, three with psoriatic arthritis, two with reactive arthritis and six with undifferentiated SSp). Fourteen patients scored from 2 to 4 on the intensity of uptake scale. The colon and terminal ileum were predominantly involved. Axial involvement was more frequent in patients with a positive scan than in patients with negative results (P 99m Tc-HMPAO-labelled leucocyte scan shows increased uptake among patients with SSp without evidence of IBD. These findings provide new evidence linking SSp with intestinal inflammation and suggest that in some cases a bowel-related process could contribute to the development of SSp. Long-term follow-up studies with more patients are necessary to evaluate the diagnostic and therapeutic implications of these results. (orig.). With 3 figs., 3 tabs

  8. In Vitro Ability of Currently Available Oximes to Reactivate Organophosphate Pesticide-Inhibited Human Acetylcholinesterase and Butyrylcholinesterase

    Directory of Open Access Journals (Sweden)

    Kamil Musilek

    2011-03-01

    Full Text Available We have in vitro tested the ability of common, commercially available, cholinesterase reactivators (pralidoxime, obidoxime, methoxime, trimedoxime and HI-6 to reactivate human acetylcholinesterase (AChE, inhibited by five structurally different organophosphate pesticides and inhibitors (paraoxon, dichlorvos, DFP, leptophos-oxon and methamidophos. We also tested reactivation of human butyrylcholinesterase (BChE with the aim of finding a potent oxime, suitable to serve as a “pseudocatalytic” bioscavenger in combination with this enzyme. Such a combination could allow an increase of prophylactic and therapeutic efficacy of the administered enzyme. According to our results, the best broad-spectrum AChE reactivators were trimedoxime and obidoxime in the case of paraoxon, leptophos-oxon, and methamidophos-inhibited AChE. Methamidophos and leptophos-oxon were quite easily reactivatable by all tested reactivators. In the case of methamidophos-inhibited AChE, the lower oxime concentration (10−5 M had higher reactivation ability than the 10−4 M concentration. Therefore, we evaluated the reactivation ability of obidoxime in a concentration range of 10−3–10−7 M. The reactivation of methamidophos-inhibited AChE with different obidoxime concentrations resulted in a bell shaped curve with maximum reactivation at 10−5 M. In the case of BChE, no reactivator exceeded 15% reactivation ability and therefore none of the oximes can be recommended as a candidate for “pseudocatalytic” bioscavengers with BChE.

  9. Perfusion scintigraphy in acute myocardial infarction

    International Nuclear Information System (INIS)

    Schricke, U.; Schwaiger, M.; Kastrati, A.; Schoemig, A.

    1999-01-01

    The Tc-99m sestamibi perfusion SPECT scintigraphy in acute myocardial infarction is a feasible method to assess the size of area at risk and the residual blood flow to this area as the most important determinants of final infarct size without any delay in treatment. In combination with a follow-up study final infarct size as well as myocardial salvage can be quantified. Clinical indications for the use of Tc-99m sestamibi scintigraphy are the noninvasive identification of arterial occlusion in patients suspected to acute myocardial infarction without electrocardiographic ST-elevation and the assessment of reperfusion success. In clinical trials Tc-99m sestamibi scintigraphy has proven to be a useful method to assess the impact of varying reperfusion therapies. The present review article discusses the indication, the study protocol, the interpretation of results and the clinical and scientifically importance of this method. (orig.) [de

  10. The effects of aminophylline infusion in the treatment of children with acute asthma exacerbation. Evaluation with 81mKr ventilation scintigraphy

    International Nuclear Information System (INIS)

    Matsubara, Yasuko; Shimada, Takao

    1998-01-01

    The use of intravenous aminophylline in the treatment of children with acute asthma remains controversial. Most authors suggest that aminophylline be used with caution because of its poor efficacy with adverse reactions and instead recommend other drugs, such as β 2 -adrenergic agonists and glucocorticoids. However other studies have reported the benefits of aminophylline, and current Japanese guidelines for the management of asthma recommend its use. Here, we have evaluated the efficacy of aminophylline infusion in children with acute asthma exacerbations. Twenty children with acute asthma exacerbations were given an infusion of 5 mg/kg of aminophylline over 5 minutes, 30 minutes after the same volume of normal saline had been infused as a control. 81m Kr ventilation scintigraphy was done sequentially, and lung function was measured with spirometry before and after each infusion. Side effects were also evaluated with a questionnaire. Ventilation images obtained with 81m Kr scintigraphy, which initially showed widespread ventilatory defects caused by bronchoconstriction, decreased 54.9% after aminophylline infusion (p 81m Kr bolus inhalation procedure, also showed significant improvement (p<0.0001). These improvement were accompanied by improvements in lung function as assessed with forced expiratory volume in 1 second (p<0.01) and maximum expiratory flow rates at 25% (p<0.001) and 50% (p<0.001). No serious adverse reactions were recognized in any subjects. Our results show that aminophylline is a useful bronchodilator which decreased ventilatory imbalance and improves lung function in both central and peripheral airways. (author)

  11. Scintigraphy of the cerebrospinal fluid

    International Nuclear Information System (INIS)

    Touya, E.; Perillo, W.; Paez, A.; Osorio, A.; Ferrando, R.; Lago, G.; Garcia Guelfi, A.; Ferrari, M.

    1977-01-01

    Eight years of experience in scintigraphy of cerebrospinal fluid (CSF) with 113 Insup(m)-colloid is reported. Two hundred cases are discussed. On the basis of the clinical diagnosis, the cases are divided into five groups: (1) spinal cord compression; (2) hydrocephalus of the adult and child; (3) control of extracranial CSF shunts; (4) CSF fistula; and (5) brain tumour. It is concluded that the radiopharmaceutical used has no limitations except in the study of the hydrocephalus of the adult. For those services remote from the production centres, it is a convenient option for CSF scintigraphy. (author)

  12. Selective coronary scintigraphy

    International Nuclear Information System (INIS)

    Gambini, D.-J.

    1975-01-01

    Isotopic techniques occupy a leading place amongst examinations practicable on coronary patients because of their reliability and the safety and simplicity of their use. The present work reviews the possible applications of selective coronary scintigraphy in pathology. After a brief discussion on scintigraphy, isotopic techniques for myocardium research, coronarography and other methods to study local myocardium perfusion the theoretical bases for the use of the exploration are studied, the techniques and methods employed are reported and the results discussed. Coronary scintigraphy consists of selective injection in the two coronary arteries previously catheterized during a coronarography, of two different populations of microspheres labelled with two physically short-lived indicators: 15μ 99m Tc-labelled serumalbumin microspheres, 10 to 15μ In-labelled siderophiline microspheres. Various studies have shown the complete harmlessness of the exploration when certain precautions are taken regarding the size and number of the spheres. The microspheres disperse into the downstream arterial territory proportionally to the number of capillaries present in the different parts of the irrigated region, and are temporarily stopped in the precapillaries. The preparation of the different images needed to interpret the Face and OAG examination for the left coronary, then for the right coronary, is carried out at the end of the coronarography and lasts about 45 minutes. It is also possible by selective injection in the aorta-coronary bridges to judge their functional condition by observation of the regions they irrigate. 56 patients of the Necker hospital cardiological clinic have been examined [fr

  13. Sodium pertechnetate scintigraphy in detection of Meckel's diverticulum

    DEFF Research Database (Denmark)

    Poulsen, K A; Qvist, N

    2000-01-01

    OBJECTIVE: To evaluate the results of 99mTc-Na-pertechnetate scintigraphy in children presenting with symptoms suspicious of Meckel's diverticulum (MD). METHOD: Retrospective study. A total of 55 99mTc-Na-pertechnetate scintigraphies in 53 patients were compared with the results from surgery and ...

  14. Role of scintigraphy and computer-assisted tomography in brain examination

    International Nuclear Information System (INIS)

    Akerman, M.; Oproiu, A.; Comoy, C.; Guiot, G.

    1981-01-01

    To assess the role of computer-assisted tomography (CAT) and scintigraphy in brain exploration, the authors analysed: (1) the diagnostic effectiveness of the two methods in 300 patients examined over a period of seven months; (2) the role assigned to each investigation in 169 patients operated on for intracranial lesion during the same period. The isotopic brain examination always included an initial angiographic study after the intravenous injection of a technetium compound. Study of the circulation of the cerebrospinal fluid was made with 111 In-DTPA. The detection efficiency of CAT is higher than for scintigraphy in expansive processes, whereas, conversely, in cerebrovascular accidents of ischaemic origin, isotope angiography coupled with static imaging enables one to gain more information on cerebral perfusion than CAT. Similarly, when studying the cerebrospinal fluid, scintigraphy provides a greater amount of specific data on the mechanisms governing hydrocephalus, the mode of operation of a shunt, or the site of a cerebrospinal fluid fistula. Within a neurosurgical context, CAT by and large takes precedence in brain examination, but the investigation is usually accompanied by scintigraphy or a conventional neuroradiological examination. Scintigraphy was performed on 66% of the patients, whereas for neuroradiological examination the figure was 44%. Most of the scintigraphy came after CAT so as to obtain additional diagnostic information on the vascularization, the nature and, on occasion, the exact location of the lesion revealed by CAT. In more than one case out of two, scintigraphy provides enough additional information for one to avoid neuroradiological examination, which is more 'aggressive' and more dangerous. Hence scintigraphy represents an effective complement to CAT and can compete with the conventional neuroradiological technique. (author)

  15. The Design, Synthesis and Screening of Potential Pyridinium Oxime Prodrugs

    Science.gov (United States)

    1984-02-01

    Our intent is to take advantage of this trapping mechanism using nucleophiles (X) such as SCN, SO3H, I, Br and OCN, which we hope will be as labile...pH 3.5-10.5. The advantage of the system stemmed from the fact that each pyridinium oxime regenerator has a discrete -max which is pH dependent. 2-PAM...with matching 3 cm guard columns. Normal phase analysis was performed "on an Alltech 0.5 x 25 cm silica gel 10 p column with 3 cm guard column and

  16. Osseous scintigraphy and auxiliary graft. Scintigraphie osseuse et greffe d'appoint

    Energy Technology Data Exchange (ETDEWEB)

    Khelifa, F.; Siles, S. (Hopital de la Timone, 13 - Marseille (France)); Puech, B.

    1992-12-01

    The scintigraphy could be a good way to survey the osseous graft: three cases are studied in which were recognized the presence of a graft, surinfection, graft lysis, pseudo-arthrosis, algodystrophy. 8 refs., 5 figs.

  17. The clinical use of platelet scintigraphy with 111-In-oxine

    International Nuclear Information System (INIS)

    Kessler, C.; Reuther, R.; Berentelg, J.; Kimmig, B.

    1983-01-01

    Platelet scintigraphy was performed on 62 patients with cerebral ischaemia. Pathological scintigraphic images were obtained in 29 of the 62 patients. In 79.3% of these 29 patients the scan was abnormal in the vessel clinically affected. Platelet scintigraphy was abnormal in 21 of 34 patients with normal angiogram or only slight atherosclerosis. In patients undergoing antiplatelet therapy, platelet scintigraphy was less often positive than in untreated patients. It is suggested that platelet scintigraphy could be an appropriate technique for detecting small mural thrombi of the carotid artery, which are the source of arterio-arterial emboli, and for controlling the efficiency of antiplatelet therapy. (orig.) [de

  18. Positive thyroid cancer scintigraphy using technetium-99m methoxyisobutylisonitrile

    International Nuclear Information System (INIS)

    Nemec, J.; Nyvltova, O.; Blazek, T.; Vlcek, P.; Racek, P.; Novak, Z.; Preiningerova, M.; Hubackova, M.; Krizova, M.; Zimak, J.; Bilek, R.

    1996-01-01

    The aim of the study was to evaluate the possibility of detecting thyroid cancer recurrences without the need for withdrawal of thyroid suppressive treatment. Upper-body or whole-body scintigraphy was performed in a group of 200 patients evaluated for differentiated thyroid cancers in 1993 and 1994 using technetium-99m sestamibi. Scans were performed 20-30 min following i.v. administration of 500 MBq of 99m Tc-methoxyisobutylisonitrile (MIBI). Bone and lung metastases were detected with very high sensitivity and specificity, with a very high predictive value of negative results and a somewhat lower predictive value of positive results. The sensitivity and specificity of findings in the neck were lower but the predictive value of negative results was high. Whole-body scans with 99m Tc-MIBI are a useful tool in the follow-up of patients with differentiated thyroid cancer, for the detection of distant metastatic lesions. (orig.)

  19. First clinical evaluation of radioimmunoimaging using anti-human lung cancer monoclonal antibodies

    International Nuclear Information System (INIS)

    Zhou Qian

    1991-01-01

    Anti-human large cell lung cancer monoclonal antibodies (McAb) 2E3 and 6D1 were produced in the laboratory. Immunohistochemical studies and radiobinding assay showed these antibodies possessed high specificity against lung cancer cells. 28 patients with lung masses were investigated with 131 I-labeled McAb 6D1 and/or 2E3 scintigraphy. 19 of them were histologically proven and 13 were diagnosed primary lung carcinoma. Radioimmunoimaging visualized 10/13 of the primary lung cancers with a detection rate of 77%. Only 1 case of the non-cancer patients and a false localization, giving a true negative rate of 83%. Pathologically the squamous cell lung carcinoma had the highest localization and the small cell lung carcinoma next, but the detection rate was 100% for both. The adenocarcinoma of lung was less sensitive to these McAbs, with a detection rate of only 33% (1 of 3 cases). We conclude that radioimmunoimaging with anti-human large cell lung cancer McAbs is more specific and effective in detecting primary lung cancers and differentiating lung masses than with antibodies against other tumor associated antigens

  20. Cp*Co(III) Catalyzed Site-Selective C-H Activation of Unsymmetrical O-Acyl Oximes: Synthesis of Multisubstituted Isoquinolines from Terminal and Internal Alkynes.

    Science.gov (United States)

    Sun, Bo; Yoshino, Tatsuhiko; Kanai, Motomu; Matsunaga, Shigeki

    2015-10-26

    The synthesis of isoquinolines by site-selective C-H activation of O-acyl oximes with a Cp*Co(III) catalyst is described. In the presence of this catalyst, the C-H activation of various unsymmetrically substituted O-acyl oximes selectively occurred at the sterically less hindered site, and reactions with terminal as well as internal alkynes afforded the corresponding products in up to 98 % yield. Whereas the reactions catalyzed by the Cp*Co(III) system proceeded with high site selectivity (15:1 to 20:1), use of the corresponding Cp*Rh(III) catalysts led to low selectivities and/or yields when unsymmetrical O-acyl oximes and terminal alkynes were used. Deuterium labeling studies indicate a clear difference in the site selectivity of the C-H activation step under Cp*Co(III) and Cp*Rh(III) catalysis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Functional scintigraphy of pulmonary ventilation with 133Xe in juvenile scoliosis

    International Nuclear Information System (INIS)

    Grau, M.; Leisner, B.; Rohloff, R.; Fink, U.; Moser, E.; Matzen, K.A.; Haeusinger, K.; Muenchen Univ.; Muenchen Univ.

    1981-01-01

    Twenty children with severe scoliosis underwent spirometry, chest X-ray and 133 Xe ventilation studies before surgical correction by the Harrington operation. By means of functional scintigraphy the relative distribution of the functional residual capacity (FRC) and the wash-out curves (3 min-retention without background correction, mean time constant, effectivity index after background correction) were analysed quantitatively. The chest X-ray and the single-breath-phase of the ventilation study remained mostly unchanged, whereas the shifting of the FRC distribution towards the lung of the concave side indicated in all cases a regional ventilation restriction of the convex side. In addition the analysis of the wash-out curves showed a regional impairment of the alveolar ventilation of the convex side which exceeded the shifting of FRC distribution. Even in the cases with normal spirometric values all scintigraphic parameters were slightly pathological, probably due to the decreased lung function caused by the scoliosis. The effectivity index taking into account the respiration frequency, the tidal volume, the FRC and the dead space, was found to be the most accurate and sensitive parameter for the evaluation of regional ventilation impairment. (orig.) [de

  2. Oxidation of primary amines to oximes with molecular oxygen using 1,1-diphenyl-2-picrylhydrazyl and WO3/Al2O3 as catalysts.

    Science.gov (United States)

    Suzuki, Ken; Watanabe, Tomonari; Murahashi, Shun-Ichi

    2013-03-15

    The oxidative transformation of primary amines to their corresponding oximes proceeds with high efficiency under molecular oxygen diluted with molecular nitrogen (O2/N2 = 7/93 v/v, 5 MPa) in the presence of the catalysts 1,1-diphenyl-2-picrylhydrazyl (DPPH) and tungusten oxide/alumina (WO3/Al2O3). The method is environmentally benign, because the reaction requires only molecular oxygen as the terminal oxidant and gives water as a side product. Various alicyclic amines and aliphatic amines can be converted to their corresponding oximes in excellent yields. It is noteworthy that the oxidative transformation of primary amines proceeds chemoselectively in the presence of other functional groups. The key step of the present oxidation is a fast electron transfer from the primary amine to DPPH followed by proton transfer to give the α-aminoalkyl radical intermediate, which undergoes reaction with molecular oxygen and hydrogen abstraction to give α-aminoalkyl hydroperoxide. Subsequent reaction of the peroxide with WO3/Al2O3 gives oximes. The aerobic oxidation of secondary amines gives the corresponding nitrones. Aerobic oxidative transformation of cyclohexylamines to cyclohexanone oximes is important as a method for industrial production of ε-caprolactam, a raw material for Nylon 6.

  3. Efficient Construction of Energetic Materials via Nonmetallic Catalytic Carbon-Carbon Cleavage/Oxime-Release-Coupling Reactions.

    Science.gov (United States)

    Zhao, Gang; He, Chunlin; Yin, Ping; Imler, Gregory H; Parrish, Damon A; Shreeve, Jean'ne M

    2018-03-14

    The exploitation of C-C activation to facilitate chemical reactions is well-known in organic chemistry. Traditional strategies in homogeneous media rely upon catalyst-activated or metal-mediated C-C bonds leading to the design of new processes for applications in organic chemistry. However, activation of a C-C bond, compared with C-H bond activation, is a more challenging process and an underdeveloped area because thermodynamics does not favor insertion into a C-C bond in solution. Carbon-carbon bond cleavage through loss of an oxime moiety has not been reported. In this paper, a new observation of self-coupling via C-C bond cleavage with concomitant loss of oxime in the absence of metals (either metal-complex mediation or catalysis) results in dihydroxylammonium 5,5-bistetrazole-1,10-diolate (TKX-50) as well as N, N'-([3,3'-bi(1,2,4-oxadiazole)]-5,5'-diyl)dinitramine, a potential candidate for a new generation of energetic materials.

  4. Liver scintigraphy of fulminant hepatitis

    International Nuclear Information System (INIS)

    Tamaki, Nagara; Ishihara, Takashi; Mori, Toru

    1980-01-01

    The liver scintigraphies of five patients with fulminant hepatitis were examined. Scintiphotos using sup(99m)Tc-phytate were taken within two weeks after the onset. Scintiphotos of 12 normal subjects, 11 cases with acute hepatitis, 17 cases with liver cirrhosis were served as control. Their scintiphotos showed reduction of the size, well-maintained uptake, mostly homogenous RI distribution, and no left lobe enlargement, which could differentiate them from the chronic liver dysfunction. In one of the cases chronological changes in liver scintigraphy were observed. The size of the liver was reduced progressively until the 16th day and re-enlarged at the 30th day and thereafter. Three indices [S/W, (R + L)/W, and L/R] were calculated. S: area of liver, R or L: longitudinal length of the right or left lobe, W: body width. Relative size of the liver expressed by S/W or (R + L)/W showed significant reduction in fulminant hepatitis compared with acute hepatitis. However, they were not different significantly from those of normal subjects. Except for liver cirrhosis, L/R (left lobe swelling index) did not show significant differences among fulminant hepatitis, normal subjects, and acute hepatitis. These indices were also useful in follow-up study of the liver scintigraphy. The liver scintigraphy in the early phase of fulminant hepatitis seems to reflect the degree of massive hepatic necrosis. It is also useful to differentiate chronic hepatic failure. Apparant reduction in scintigraphical liver size seems to suggest poor prognosis, however, it should also kept in mind that the size of the liver in this condition might change quite rapidly and greatly. (author)

  5. Isoproterenol stress thallium scintigraphy for detecting coronary artery disease

    International Nuclear Information System (INIS)

    Watanabe, Shigeyuki; Ajisaka, Ryuichi; Masuoka, Takeshi; Iida, Kaname; Sugishita, Yasuro; Ito, Iwao; Takeda, Tohru; Toyama, Hinako; Akisada, Masayoshi

    1989-01-01

    The present study was undertaken to assess the diagnostic value of isoproterenol (ISP) thallium scintigraphy. The findings were compared with those of ISP-ECG and exercise thallium scintigraphy. The study population consisted of 24 patients who had a history of chest pain without previous myocardial infarction. ISP was given at increasing doses of 0.02, 0.04, 0.08 μg/mg/min at 3-minutes intervals, and was terminated for any of the following reasons: angina, significant arrhythmia, significant ST segment depression, or target heart rate. Thallium scintigrams were obtained immediately after terminating ISP infusion, and after a 3-hour delay, redistribution scans were obtained. Scintigrams were considered positive when a reversible defect was present. After stress tests, coronary angiography was performed. According to the presence or absence of significant coronary artery stenosis, the patients were divided into coronary artery disease (CAD) group (n=12) and so-called normal coronary (NC) group (n=12). Among 12 patients in the CAD group, ISP induced anginal pain in six (50%), and ISP-ECT and ISP thallium scintigraphy were positive in 10 (83%) and in 11 (92%), compared with four(33%), four(33%) and two (17%) in the NC group. These data indicate that ISP-ECG had a sensitivity of 83%, a specificity of 67%, and a diagnostic accuracy of 75%; and the corresponding figures for ISP thallium scintigraphy were 92%, 83%, and 88%. Among nine patients who underwent both ISP thallium scintgraphy and exercise thallium scintigraphy, all patients, except for one false negative case on ISP thallium scintigraphy, were correctly diagnosed. No serious complications occurred in association with the ISP infusion test. ISP thallium scintigraphy was considered to be a safe, sensitive, and specific method for diagnosing CAD when exercise tests were intolerable. (N.K.)

  6. Detectability of metastatic bone tumor by Ga-67 scintigraphy

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Uchiyama, Guio; Araki, Tsutomu; Hihara, Toshihiko; Ogata, Hitoshi; Monzawa, Shuichi; Kachi, Kenji; Matsusako, Masaki

    1989-01-01

    Ga-67 scintigrams in patients with malignant diseases sometimes reveal uptake of the tracer in the bone metastases. Detectability of Ga-67 scintigraphy for metastatic bone tumors and benign bone lesions was compared with that of Tc-99m bone scintigraphy. Countable bone metastases detected by bone scintigraphy were evaluated whether the lesion showed apparent, faint, or negative Ga-67 uptake. Of 47 lesions 23 (49%) showed apparent uptake and 17 (36%) showed negative uptake, only 7 (10%) mostly fracture/osteotomy, showed apparent uptake of the tracer. Uptake in the other benign lesions such as trauma of the ribs, spondylosis deformans, and arthrosis deformans was rather faint. In patients with multiple bone metastases, 9 patients (82%) out of 11 showed more prominent abnormal findings in Tc-99m MDP bone scintigraphy than in Ga-67 scintigraphy; that is, Ga-67 scintigraphy was not able to reveal all metastatic bone lesions. In patients with untreated or recurrent tumors, relation between Ga-67 uptake in the tumors and that in the bone metastases was evaluated. Of 7 patients with negative Ga-67 uptake in the bone metastases; that is, there seemed to be little relation between Ga-67 affinity to the primary tumors and that to the bone metastases. Mechanisms of the Ga-67 uptake in the bone metastases were discussed. Not only the tumor cells or tissues in the bone metastases but also bone mineral or osteoclasts might be the deposition sites of Ga-67. (author)

  7. Detectability of metastatic bone tumor by Ga-67 scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Koizumi, Kiyoshi; Uchiyama, Guio; Araki, Tsutomu; Hihara, Toshihiko; Ogata, Hitoshi; Monzawa, Shuichi; Kachi, Kenji; Matsusako, Masaki

    1989-03-01

    Ga-67 scintigrams in patients with malignant diseases sometimes reveal uptake of the tracer in the bone metastases. Detectability of Ga-67 scintigraphy for metastatic bone tumors and benign bone lesions was compared with that of Tc-99m bone scintigraphy. Countable bone metastases detected by bone scintigraphy were evaluated whether the lesion showed apparent, faint, or negative Ga-67 uptake. Of 47 lesions 23 (49%) showed apparent uptake and 17 (36%) showed negative uptake, only 7 (10%) mostly fracture/osteotomy, showed apparent uptake of the tracer. Uptake in the other benign lesions such as trauma of the ribs, spondylosis deformans, and arthrosis deformans was rather faint. In patients with multiple bone metastases, 9 patients (82%) out of 11 showed more prominent abnormal findings in Tc-99m MDP bone scintigraphy than in Ga-67 scintigraphy; that is, Ga-67 scintigraphy was not able to reveal all metastatic bone lesions. In patients with untreated or recurrent tumors, relation between Ga-67 uptake in the tumors and that in the bone metastases was evaluated. Of 7 patients with negative Ga-67 uptake in the bone metastases; that is, there seemed to be little relation between Ga-67 affinity to the primary tumors and that to the bone metastases. Mechanisms of the Ga-67 uptake in the bone metastases were discussed. Not only the tumor cells or tissues in the bone metastases but also bone mineral or osteoclasts might be the deposition sites of Ga-67.

  8. Diagnostic usefulness of technetium-99m (V) DMSA scintigraphy in cases of soft tissue tumors; In comparison with that of Ga-67 citrate scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hisataka; Kotoura, Yoshihiko; Hanbara, Harumi; Hosono, Makoto; Yamamuro, Takao; Konishi, Junji (Kyoto Univ. (Japan). Faculty of Medicine)

    1994-05-01

    Technetium-99m (V) DMSA scintigraphy was performed in 76 patients with pathologically confirmed soft tissue diseases. In 56 patients, gallium-67 citrate scintigraphy was performed within two weeks after technetium-99m (V) DMSA scintigraphy. Significant uptake of technetium-99m (V) DMSA was found in all cases of sarcoma, metastatic carcinoma, progressive benignancy (extra-abdominal desmoid etc.) and granulomatous lesions, but was not found in cases of benign, solid tumors in the soft tissue (leiomyoma, neurinoma, lipoma etc.). In conclusion, it is not necessary to treat patients with soft tissue tumors in which technetium-99m (V) DMSA did not accumulate. Therefore, it can be stated that technetium-99m (V) DMSA scintigraphy is useful for the screening of malignant tumors. (author).

  9. 99mTc-MDP bone scintigraphy findings representing osteoporosis

    International Nuclear Information System (INIS)

    Nam, Dae Gun; Moon, Tae Geon; Kim, Ji Hong; Son, Seok Man; Kim, In Ju; Kim, Yong Ki

    2001-01-01

    Bone scintigraphy with 99m Tc-labeled phosphates is one of the most common procedures in evaluation of various skeletal disorders. Metabolic bone diseases show involvement of the whole skeleton and are associated with increased bone turnover and increased uptake of 99m Tc-labeled phosphates. In this study, we investigated apparently normal women who were examined with routine bone scintigraphy applied bone densitometry to correlate it with skeletal uptake in bone scan. This study includes 79 women who were performed both of bone mineral density(BMD) and bone scintigraphy. We investigated the relation of bone scan findings and BMD of lumbar, femur, radius. Regional BMD were negatively correlated with increased age. Among the bone scintigraphy findings representing metabolic bone disease, uptakes by the long bones, skull and mandible increased with age in women, while that in the costochondral junction decreased. Increased skull and mandible uptakes is associated with decreased BMD, and it has statistically significance. Our results show that increased radionuclide uptake in bone scintigraphy, especially skull and mandible uptake was associated with decreased lumbar, femur BMD in women. So that, increased skull and mandible uptake in women would be a scintigraphic sign of osteopenia or osteoporosis

  10. Bone scintigraphy during therapy with cytostatically acting drugs

    International Nuclear Information System (INIS)

    Schmidt, U.; Pries, H.H.; Joseph, K.; Mahlstedt, J.; Marburg Univ.

    1976-01-01

    Case reports show up, that bone scintigraphy during therapy of metastasing cancer of mamma or prostata with cytostatically acting drugs may reveal 'pseudonormal' results. False negative diagnosis can be excluded only by carefully regarding drug history. Gamma-camera with wholebody scan device for scintigraphy in two projections simplifies safe evaluation significantly. (orig.) [de

  11. Diagnostic value of bone scintigraphy in patients with low back pain

    Energy Technology Data Exchange (ETDEWEB)

    Schuette, H.E.; Park, W.M.

    1983-06-01

    Bone scintigraphy has been studied in two groups of patients with low back pain. In one group of 38 patients suffering ''non-specific'' back pain, bone scintigraphy and laboratory findings were negative in 24. There were abnormal laboratory findings in all of the remaining 14 and 7 had positive bone scans indicative of clinically significant disease. Selection of patients for bone scintigraphy in this group should therefore be influenced by abnormal laboratory findings and elevation of the erythrocyte sedimentation rate in particular. By comparison, the bone scans were reviewed from another group of patients suffering previously known malignancy. Out of 138 patients, nearly 40% showed a positive bone scan due to subsequently proven metastasis. Bone scintigraphy was positive in a further 14% as a result of osteoporotic rib fracture and vertebral body collapse. In half of these, it was not possible to exclude malignancy by scintigraphy. The present findings indicate that bone scintigraphy is not a useful procedure in patients with long-standing low back pain who have normal radiographs and normal laboratory findings.

  12. Our experience on the diagnostic possibilities of pancreas scintigraphy

    International Nuclear Information System (INIS)

    Centi Colella, A.; Pistoni, F.

    1975-01-01

    Several years experience on the real diagnostic possibilities of a pancreas scintigraphy method are reported, with special reference to the differentiation between malignant neoplasias and chronic pancreatitis. In this respect, account is taken of certain eminently functional parameters which can be determined by traditional scintigraphy and by sequential static scintigraphy with the Anger gamma camera. The parameters in question are: degree of definition of the pancreas image; amount of 75 Se-labelled selenomethionine uptake by the stomach and the jejunum; time of appearance of the pancreatic radioactivity [fr

  13. Our experience on the diagnostic possibilities of pancreas scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Centi Colella, A; Pistoni, F [Rome Univ. (Italy)

    1975-01-01

    Several years experience on the real diagnostic possibilities of a pancreas scintigraphy method are reported, with special reference to the differentiation between malignant neoplasias and chronic pancreatitis. In this respect, account is taken of certain eminently functional parameters which can be determined by traditional scintigraphy and by sequential static scintigraphy with the Anger gamma camera. The parameters in question are: degree of definition of the pancreas image; amount of /sup 75/Se-labelled selenomethionine uptake by the stomach and the jejunum; time of appearance of the pancreatic radioactivity.

  14. Bone- and bone marrow scintigraphy in Gaucher disease type 1

    International Nuclear Information System (INIS)

    Mikosch, P.; Zitter, F.; Gallowitsch, H.J.; Lind, P.; Wuertz, F.; Mehta, A.B.; Hughes, D.A.

    2008-01-01

    Scintigraphy is a method for imaging metabolism and should be viewed as complimentary to morphological imaging. Bone and bone marrow scintigraphy can particularly contribute to the detection of focal disease in Gaucher disease. In bone crises it can discriminate within three days after pain onset between local infection and aseptic necrosis. A further advantage of bone- and bone marrow scintigraphy is the visualization of the whole skeleton within one setting. Whole body imaging for focal lesions might thus be an objective in GD, in particular in patients complaining of several painful sites. Direct imaging of bone marrow deposits in GD by MIBI scintigraphy might be of special interest in children in whom bone marrow undergoes a developmental conversion from red to yellow marrow in the ap-pendicular skeleton. MRI interpretation in young GD patients is thus difficult in order to estimate the exact amount and extent of bone marrow infiltration by Gaucher cells. 99mTc-MIBI scintigraphy with its direct visualization of lipid storage could thus add interesting additional information not shown with other methods including MRI. Although MRI is the most accepted imaging modality in assessing the skeletal status in GD, a selective use of scintigraphy for imaging bone and bone marrow may add information in the evaluation of patients with Gaucher disease

  15. Clinical usage of indium-111 labeled leukocyte scintigraphy and technetium-99m methylene diphosphonate scintigraphy in patients with total hip replacement

    International Nuclear Information System (INIS)

    Terauchi, Takashi; Uno, Kimiichi; Yuyama, Takuo; Seto, Kazuhiko; Arimizu, Noboru; Suguro, Tohru; Moriya, Hideshige; Uematsu, Sadao.

    1988-01-01

    Tc-99m methylene diphosphonate (MDP) scintigraphy and In-111 labeled leukocyte scintigraphy were done in 13 patients with total hip replacement in order to determine the presence of prosthetic infection. Tc-99m MDP scintigraphy was done in 11 patients (12 studies). In-111 labeled leukocyte scintigraphy was done in 13 patients (14 studies). Tc-99m MDP imaging showed diffuse accumulation of the radionuclide in all of the 3 infected lesions, but focal one in 5 of the 7 noninfected lesions with a specificity of 33.3 %, sensitivity of 100 %, overall accuracy of 50 %. In-111 labeled leukocyte normally accumulates in the spleen, the liver, and the bone marrow. Before insertion of a stemmed prosthesis, the local bone marrows were reamed out in all of our cases. Thus, no radioactive accumulation would be expected in the lesions with prosthesis unless infected. However, if the prosthesis is infected, increased uptake of In-111 would be seen as a result of the accumulation of leukocyte. In-111 labeled leukocyte imaging showed abnormal accumulation of In-111 in all of the 4 infected lesions and no accumulation in all of the 10 noninfected lesions with a specificity of 100 %, sensitivity of 100 %, overall accuracy of 100 %. We conclude that In-111 labeled leukocyte scintigraphy might be useful in evaluating prosthetic infection in a patient with total hip replacement. (author)

  16. Energetics of Ortho-7 (oxime drug translocation through the active-site gorge of tabun conjugated acetylcholinesterase.

    Directory of Open Access Journals (Sweden)

    Vivek Sinha

    Full Text Available Oxime drugs translocate through the 20 Å active-site gorge of acetylcholinesterase in order to liberate the enzyme from organophosphorus compounds' (such as tabun conjugation. Here we report bidirectional steered molecular dynamics simulations of oxime drug (Ortho-7 translocation through the gorge of tabun intoxicated enzyme, in which time dependent external forces accelerate the translocation event. The simulations reveal the participation of drug-enzyme hydrogen bonding, hydrophobic interactions and water bridges between them. Employing nonequilibrium theorems that recovers the free energy from irreversible work done, we reconstruct potential of mean force along the translocation pathway such that the desired quantity represents an unperturbed system. The potential locates the binding sites and barriers for the drug to translocate inside the gorge. Configurational entropic contribution of the protein-drug binding entity and the role of solvent translational mobility in the binding energetics is further assessed.

  17. Pulmonary scintigraphy using 197HgCl2 and pulmonary perfusion scintigraphy in bronchopulmonary diseases

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Kanai, Hisakata; Handa, Kenjiro; Kusama, Shozo

    1981-01-01

    75 patients with pulmonary tuberculosis and 106 patients with bronchopulmonary diseases whose chest x-rays showed diffuse shadows were studied. Pulmonary scintigraphy using 197 HgCl 2 was useful for the diagnosis of the localization and the activity of pulmonary tuberculosis, because 197 HgCl 2 readily accumulated in the foci, and its accumulation rate was related to the activity of the foci. 197 HgCl 2 also accumulated markedly in foci of pneumoconiosis, especially, in areas showing large shadows and foci suspected to be tuberculosis. 197 HgCl 2 also accumulated in areas of chronic bronchitis, diffuse interstitial pneumonia and bronchiectasis. Its accumulation was considered to have a relation to the activity of inflammation. In primary pulmonary carcinoma, 197 HgCl 2 accumulated most markedly, in the primary lesions. 197 HgCl 2 also accumulated in metastatic or invasion areas of the hilus and the mediastinum. It accumulated in intrapulmonary metastatic foci of pulmonary carcinoma and multiple metastatic pulmonary tumors, but it was difficult to differentiate these diseases from other pulmonary diseases. In selected cases, it was useful to use pulmonary scintigraphy using 197 HgCl 2 together with pulmonary perfusion scintigraphy for the diagnosis of diffuse bronchopulmonary diseases. (Tsunoda, M.)

  18. Quantitative evaluation of dysphagia using scintigraphy

    International Nuclear Information System (INIS)

    Park, Seok Gun; Hyun, Jung Keun; Lee, Seong Jae

    1998-01-01

    To evaluate dysphagia objectively and quantitatively, and to clarify the effect of neck position and viscosity changes in patients with aspiration and laryngeal penetration. We studied 35 patients with dysphagia and 21 normal controls using videofluoroscopy and scintigraphy. Videofluoroscopy was performed with barium with three different viscosity, and scintigraphy was done with water, yogurt, and steamed egg mixed with Tc-99m tin colloid. If aspiration was found during videofluoroscopic examination, patient's neck position was changed and study repeated. Videofluoroscopy was analyzed qualitatively. We calculated 7 quantitative parameters from scintigraphy. According to the videofluoroscopic findings, we divided patients into 3 subgroups; aspiration, laryngeal penetration, and no-aspiration group. The result of videofluoroscopy revealed that the most common finding was the delay in triggering pharyngeal swallow. Pharyngeal transit time (PTT) and pharyngeal swallowing efficiency (PSE) in patients with aspiration were significantly different from other groups. After neck position change, aspiration could be reduced in all of 7 patients, and laryngeal penetration reduced by about 82%. PTT and PSE were also improved after position change. Aspiration and laryngeal penetration occurred more frequently in thin liquid swallowing than in thin liquid and solid swallowing. PTT and PSE were useful for the evaluation of dysphagia. Aspiration and laryngeal penetration could by reduced when appropriate position assumed. We could decrease the chance of aspiration by changing the patient diet consistency. Scintigraphy might be useful tool to quantitate and follow up these changes

  19. Quantitative evaluation of dysphagia using scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seok Gun; Hyun, Jung Keun; Lee, Seong Jae [College of Medicine, Dankook Univ., Cheonnon (Korea, Republic of)

    1998-08-01

    To evaluate dysphagia objectively and quantitatively, and to clarify the effect of neck position and viscosity changes in patients with aspiration and laryngeal penetration. We studied 35 patients with dysphagia and 21 normal controls using videofluoroscopy and scintigraphy. Videofluoroscopy was performed with barium with three different viscosity, and scintigraphy was done with water, yogurt, and steamed egg mixed with Tc-99m tin colloid. If aspiration was found during videofluoroscopic examination, patient's neck position was changed and study repeated. Videofluoroscopy was analyzed qualitatively. We calculated 7 quantitative parameters from scintigraphy. According to the videofluoroscopic findings, we divided patients into 3 subgroups; aspiration, laryngeal penetration, and no-aspiration group. The result of videofluoroscopy revealed that the most common finding was the delay in triggering pharyngeal swallow. Pharyngeal transit time (PTT) and pharyngeal swallowing efficiency (PSE) in patients with aspiration were significantly different from other groups. After neck position change, aspiration could be reduced in all of 7 patients, and laryngeal penetration reduced by about 82%. PTT and PSE were also improved after position change. Aspiration and laryngeal penetration occurred more frequently in thin liquid swallowing than in thin liquid and solid swallowing. PTT and PSE were useful for the evaluation of dysphagia. Aspiration and laryngeal penetration could by reduced when appropriate position assumed. We could decrease the chance of aspiration by changing the patient diet consistency. Scintigraphy might be useful tool to quantitate and follow up these changes.

  20. Diagnosis by Liver Scintigraphy; Gepatoskennograficheskaya semiotika

    Energy Technology Data Exchange (ETDEWEB)

    Zubovskij, G. [Nauchno-Issledovatel Skij Rentgeno-Radiologicheskij Institut M3 RSfSR, Moskva, SSSR (Russian Federation)

    1969-05-15

    Liver scintigraphy has become one of the most important methods of diagnosing liver diseases, being used most often to discover the locus of infection. A total of 2000 patients were thus investigated and in 1200 cases the state of the liver was definitively established; for 335 of these the condition was determined by inspection during surgical operation; in 180 cases it was established on the basis of a puncture biopsy, in 55 cases by autopsy and in the remainder by clinical laboratory tests and long-term observation. 102 patients were subjected to both scintigraphy and contrast X-ray investigation of the liver. 500 conditions were ascribed to localized liver infections (fibroses, cysts and tumours) and the remaining 700 to diffuse infections (cirrhosis, hepatitis, systemic blood diseases, etc. ). On the basis of analysis of scintigrams from 1200 patients with definitively established liver conditions criteria were drawn up for use in diagnosis by liver scintigraphy, on the lines of those employed in the practice of X-ray diagnosis. These criteria include changes in the topography, shape and dimensions of the liver, the comparative degrees of contrast in the images obtained and also the appearance of the spleen and the gall bladder. It was found that depending on the type of pathological process and its distribution there occur highly characteristic indications of a change in the liver scintigram, and by evaluation of these the localization and nature of the process can be more accurately determined. The changes observed in a liver scintigram in cases of disease of the surrounding organs, such as the lungs, diaphragm, pancreas and certain others, were also determined. On the basis of detailed analysis of 88 scintigrams from patients showing no signs of liver infection, the author evolved the concept of a normal scintigraphic representation of the liver, dependent on the constitutional characteristics of the individual. A thorough knowledge of the underlying

  1. MRI contrast enhancement of the lung using as Gd-DTPA aerosol

    International Nuclear Information System (INIS)

    Bockisch, A.; Harvey, R.C.; Davis, M.A.; Kabalka, G.W.

    1993-01-01

    The efficacy of a Gd-DTPA aerosol to enhance ventilated lung parenchyma was evaluated in an MR study in anesthetized female beagle dogs. Ventilation of a 1.0-M Gd-DTPA solution was performed using a commercially available atomizer. MR imaging was performed at a 1.9 T whole body imager with an acquisition mode that was gated to respiration. To quantify the amount of ventilated Gd-DTPA experiments were repeated with 99m Tc-DTPA under identical conditions. Using ventral and dorsal digital scintigraphy, the amount of Gd-DTPA in both lungs were determined. MR imaging showed on increase of signal intensity of 70% following Gd-DTPA ventilation. Because of the inherently low signal intensity of lung parenchyma this degree of contrast enhancement is too small to be clinically useful. (orig.) [de

  2. Bone scintigraphy in the diagnosis of fracture and infection of the temporal bone

    International Nuclear Information System (INIS)

    Djupesland, G.; Nakken, K.F.; Mueller, C.; Skjoerten, F.; Roehrt, T.; Eldevik, P.

    1983-01-01

    The sensivit of Tc99m-MDP-bone-scintiscanning in the diagnosis of temporal bone fracture was found to that of conventional radiography if the patients were examined 10 days after the trauma. Temporal bone osteomyelitis with concomitant moderate osteosclerosis was demonstrated by bone scintigraphy in 5 cases of mastoiditis with atypical symptoms. A case of apicitis was for the first time demonstrated by scintigraphy. A low sensivity of 67 Ga-scintigraphy was demonstrated by positive Tc99m-bone-scintigraphy and negative 67 Ga-scintigraphy in a patient with atypical mastoiditis. Tc99m-scintigraphy was negative in 5 cases of otitis media suppurative and in 3 cases of otitis media chronica cum cholesteatoma, all with slight degree of osteosclerosis in the mastoid. The sensitivity of Tc99m-bone-scintigraphy in fracture and osteomyelitis of the temporal bone seems to be a function of the amount of reactive new bone formed. (Authors)

  3. Bone-scintigraphy in painful bipartite patella

    International Nuclear Information System (INIS)

    Iossifidis, A.; Brueton, R.N.; Nunan, T.O.

    1995-01-01

    Although, the use of technetium scintigraphy in the assessment of anterior knee pain has been described, no reference has been made to the scintigraphic appearances of painful bipartite patella. We report the scintigraphic-appearances of painful bipartite patella in 25-year-old man a 2 1/2 years history of unexplained patellar pain. Painful bipartite patella is a rare cause of chronic post-traumatic patellar pain. Bone scintigraphy, by demonstrating increased uptake by the painful accessory bipartite fragment, appears to be an imaging method of choice in the diagnosis of this condition. (orig./MG)

  4. Biliary scintigraphy in neonatal cytomegalovirus cholestasis

    International Nuclear Information System (INIS)

    Tadzher, I.S.; Grujovska, S.; Todorovski, G.; Josifovska, T.; Arsovska, S.

    1996-01-01

    Diagnostic value of hepatobiliary scintigraphy using mebrofenin-Te-99m was assessed in three newborns with cytomegalovirus (CMV) hepatitis and one baby with hepatitis B jaundice. All cases were affected by persistent jaundice with predominately conjugated bilirubin, alcoholic stools, anemia. One of this newborns (case number 1) was suspected of having biliary atresia due to the absence of intestinal excretion of the tracer. After three weeks intestinal passage was seen in scintiscan late after 24 h. Hepatobiliary scintigraphy represents a non-invasive diagnostic procedure which enables the detection of permeability of the biliary tract. (Author)

  5. Bone scintigraphy in systemic and metabolic diseases

    International Nuclear Information System (INIS)

    Engels, H.J.; Schmidt, H.A.E.

    1984-01-01

    Bone scintigraphy is a very sensitive method to identify pathological processes affecting the bone. Its specificity is, however, considerably lower than its sensitivity, particularly in systemic diseases. We therefore investigated the possibilities of differential diagnosis based on typical sites or patterns of distribution. The Paget syndrome with characteristic manifestation in the pelvic region, including crutch-shaped accumulation in the proximal femur, may be diagnosed by scintigraphy alone. If these typical sites are absent, however, differential diagnosis is difficult. Differential diagnosis for multiple myeloma, fibrous dysplasia, enchondromatosis, hyperparathyroidism, osteopathies, osteomalacia, inflammatory rheumatic diseases is also required and should be based on further examinations, taking into consideration the history, clinical signs and course. In this connexion scintigraphy is relevant both for early assessment and documentation of the spread of pathological processes and for the follow-up. (orig.) [de

  6. Bone scintigraphy for the investigation of lameness in small animals

    International Nuclear Information System (INIS)

    Bolln, G.; Franke, C.

    2010-01-01

    Bone scintigraphy has been used as a helpful method in diagnosing lameness in small animals. It is a sensitive, non-invasive method to evaluate bone lesions and orthopaedic disorders. It provides a functional image of the skeleton and thereby aiding in the localisation and diagnosing of obscure lameness. Compared to human medicine one important difference is the inability of an animal to characterize its pain to the examiner. Another difference is the lacking cooperation of an animal during bone scintigraphy. Before this background are shown on the basis of 5 examples the advantages, the method and the different indication of bone scintigraphy. The technique of this method arrives from a human medicine protocol of a 2-phase-bone-scintigraphy and has to be done under light anaesthesia, to avoid artefacts of movement during acquisitions. The authors are convinced that bone scintigraphy is a very useful and diagnostic method for evaluation of obscure lameness because it can give a quick diagnosis and aimed therapy. Therefore secondary changes and additional costs can be avoided for the animal and its owner. (orig.)

  7. Medical image transmission via communication satellite. Evaluation of bone scintigraphy

    International Nuclear Information System (INIS)

    Suzuki, Hideki; Inoue, Tomio; Endo, Keigo; Shimamoto, Shigeru.

    1995-01-01

    As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT 1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical imagings by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6±2.6% via satellite, and 93.2±2.4% on the view box and there was no significant difference between them. These results suggest that the satellite communication is very useful and effective system to send nuclear imagings to distant institutes. (author)

  8. [Medical image transmission via communication satellite: evaluation of bone scintigraphy].

    Science.gov (United States)

    Suzuki, H; Inoue, T; Endo, K; Shimamoto, S

    1995-10-01

    As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical images by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6 +/- 2.6% via satellite, and 93.2 +/- 2.4% on the view box and there was no significant difference between them. These results suggest that the satellite communication is very useful and effective system to send nuclear imagings to distant institutes.

  9. Hypertrophic osteopathy characterized by nuclear scintigraphy in a horse

    International Nuclear Information System (INIS)

    Long, M.T.; Foreman, J.H.; Wallig, M.A.; Chambers, M.D.; Losonsky, J.M.; Muhlbauer, M.C.

    1994-01-01

    A five year old American Saddlebred gelding was admitted to the University of Illinois Veterinary Medical Teaching Hospital with a history of multiple leg lameness, depression and intermittent fever for a duration of six months. Physical examination revealed the horse to be underweight, depressed and a febrile. No abnormalities were detected during auscultation of the heart and lungs. All limbs possessed multiple hard swellings of the distal long bones and digits. The horse walked witha stiff gait and was reluctant to trot. Nuclear scintigraphy of the distal limbs revealed multiple areas of focally increased uptake in all limbs. Radiographs of several sites on the distal limbs showed evidence of periosteal new bone production corresponding to the areas of abnormal uptake. The horse was euthanized and at necropsy chronic, multifocal, fibrous pericarditis and epicarditis were observed grossly. The left atrial myocardium contained areas of osseous metaplasia. Histological evaluation of the distal long bones revealed proliferative periosteal new bone formation consistent with a diagnosis of hypertrophic osteopathy

  10. Gallium-67 and subphrenic abscesses: is delayed scintigraphy necessary

    International Nuclear Information System (INIS)

    Hopkins, G.B.; Mende, C.W.

    1975-01-01

    Forty postoperative patients with clinical and roentgenographic findings suggestive of subphrenic abscess were evaluated by early and delayed 67 Ga scintigraphy. Early 67 Ga scintigraphs obtained 6 hr after injection correctly localized seven right and five left subphrenic abscesses. In no instance was an abscess present on delayed scintigraphs that was not evident on the 6-hr study. Two patients with left subphrenic abscess had false-negative results on both early and delayed scintigraphy. No false-positive studies were recorded. Early 67 Ga scintigraphy can be a valuable noninvasive adjunct in the diagnosis of subphrenic abscess. (U.S.)

  11. Risk-benefit of dipyridamole loading thallium-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Ueshima, Kenji; Ogiu, Naonori; Musha, Takehiko; Moriai, Naoki; Miyakawa, Tomohisa; Nakai, Kenji; Hiramori, Katsuhiko

    1995-01-01

    This study assessed the accuracy of dipyridamole-stressed thallium-201 scintigraphy in the detection of myocardial ischemia, as well as the associated complications and their background factors. Fifty consecutive patients (33 men and 17 women; a mean age of 67 years) unable to undergo exercise thallium imaging were examined. R waves on resting ECG, the occurrence of ischemic changes on exercise ECG, asynergy on left ventriculography and dobutamine-stressed two-dimensional echocardiography, uptake of FEG on PET, and coronary angiographic findings were comprehensively assessed to determine the accuracy of the present scintigraphy. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 60.4%, 94.2%, 89.7%, 83.0%, and 82.9%, respectively. These findings yielded satisfactory detectability of dipyridamole-stressed thallium-201 scintigraphy for myocardial ischemia. The present scintigraphy had a high sensitivity and specificity for the left anterior descending artery; however, it had a high specificity but low sensitivity for the other arteries. A majority of complications during the scintigraphy was transient, mild decrease in blood pressure, which was found especially when ischemia was present in the left circumflex artery and chest pain occurred during dipyridamole stress. Dipyridamole stress is considered to be contraindicated for patients with unstable angina. (N.K.)

  12. Decreased uptake with Sulesomab scintigraphy in a case of extra spinal osteitis;Hypofixation de la scintigraphie au sulesomab dans une osteite extrarachidienne

    Energy Technology Data Exchange (ETDEWEB)

    Ungureanu, C.M.; Angoue, O.; Blagosklonov, O.; Boulahdour, H. [CHU Jean-Minjoz, Service de medecine nucleaire, 25 - Besancon (France); Pauchot, J. [CHU Jean-Minjoz, Service de chirurgie orthopedique, traumatologique, plastique et readaptation fonctionnelle, 25 - Besancon (France)

    2010-04-15

    Decreased uptake of ischion osteitis with Sulesomab scintigraphy. We report the case of a 28-year-old man, who underwent surgery for a left gluteal muscle abscess. During the surgery multiple specimens were taken from the abscess and the left ischion. These specimens revealed a coagulase-negative Staphylococcus abscess and a coagulase-negative Staphylococcus ischion osteitis. Bone scintigraphy showed an increased uptake in the ischion, while Sulesomab scintigraphy demonstrated a decreased uptake in the same area. If a decreased uptake of Sulesomab has already been described in bone spine infection, it has not yet been described in extra spinal infectious osteitis, to our knowledge

  13. Abolished ventilation and perfusion of lung caused by blood clot in the left main bronchus

    DEFF Research Database (Denmark)

    Afzelius, P; Bergmann, A; Henriksen, J H

    2015-01-01

    /Q) scintigraphy with single-photon emission CT (SPECT)/CT. V/Q SPECT/CT demonstrated abolished ventilation due to obstruction of the left main bronchus and markedly reduced perfusion of the entire left lung, a condition that was completely reversed after removal of a blood clot. We present the first pictorially......It is generally assumed that the lungs possess arterial autoregulation associated with bronchial obstruction. A patient with pneumonia and congestive heart failure unexpectedly developed frequent haemoptysis. High-resolution CT and diagnostic CT were performed as well as ventilation/perfusion (V...

  14. Bone scintigraphy in drug addiction

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Majano, V.; Miskew, D.; Sansi, P.

    1981-01-01

    In 22 drug addicts, the clinical diagnosis of osteomyelitis and/or septic arthritis was suspected because of symptoms of sepsis and pain in various locations. All patients underwent bone scintigraphy with 17-20 mCi of /sup 99/sup(m)Tc labeling either pyrophosphate or methylene diphosphonate. Whole body and spot scans located the area of disease in most patients. This permitted biopsy of the affected area when the pathogen recurs. One of the two patients whose scintigrams were normal was on adequate treatment before the bone scintigram and the other was on oxacillin. Radiographs of the affected areas were normal, which indicates bone scintigraphy should be preferred to radiography in the early diagnosis of osseous infections.

  15. Bone scintigraphy in drug addiction

    International Nuclear Information System (INIS)

    Lopez-Majano, V.; Miskew, D.; Sansi, P.

    1981-01-01

    In 22 drug addicts, the clinical diagnosis of osteomyelitis and/or septic arthritis was suspected because of symptoms of sepsis and pain in various locations. All patients underwent bone scintigraphy with 17-20 mCi of 99 sup(m)Tc labeling either pyrophosphate or methylene diphosphonate. Whole body and spot scans located the area of disease in most patients. This permitted biopsy of the affected area when the pathogen recurs. One of the two patients whose scintigrams were normal was on adequate treatment before the bone scintigram and the other was on oxacillin. Radiographs of the affected areas were normal, which indicates bone scintigraphy should be preferred to radiography in the early diagnosis of osseous infections. (orig.) [de

  16. Scintigraphy In skeletal trauma

    African Journals Online (AJOL)

    1989-08-05

    Aug 5, 1989 ... of unsuspected fractures in a patient with multiple injuries. S Atr MedJ 1989; 76: ... of left lumbosacral pain, bone scintigraphy was performed a. Department of ... Moreover, the scan demonstrated seven rib. • •. SAMJ VOL.

  17. The independent value of exercise thallium scintigraphy to physicians

    International Nuclear Information System (INIS)

    Hlatky, M.; Botvinick, E.; Brundage, B.

    1982-01-01

    To determine the effect of exercise myocardial scintigraphy with 201 Tl on diagnostic accuracy and the need for coronary angiography, consecutive patients with a variety of clinical presentations were identified. Clinical summaries, including a detailed history, physical examination, and complete data from a standard treadmill exercise test, were presented to 91 cardiologists. The cardiologists assessed the probability of coronary disease and the need for coronary angiography. They were then presented the results of thallium scintigraphy and revised their assessments if warranted. Scintigraphy significantly increased the cardiologists' diagnostic accuracy beyond that attained with other clinical information (p less than 0.0001). The change in accuracy varied from + 4% to + 20% in different patient groups, and was greatest in patients with atypical angina and a positive exercise ECG. Ratings of the need for coronary angiography changed from -13% to +21% in different patient groups. We conclude that exercise thallium scintigraphy can provide independent diagnostic information and influence the need for coronary angiography

  18. Experience in thyroid scintigraphy with Ethiopian patients

    International Nuclear Information System (INIS)

    Demena, Solomon

    1993-01-01

    One thousand and thirty seven thyroid scintigraphy examinations done in the Nuclear Medicine Unit of Tikur Anbesma Hospital, Addis Abeba, Ethiopia between December 1984 and September 1989 were analyzed to assess their diagnostic value. Thirty one percent of the referrals were to investigate clinically detectable solitary nodules, and of these fifty-six percent had ''cold'' nodules and twenty-three percent ''hot'' nodules. Fifty-five percent of the referrals for evaluation of goitre were for multi nodular goitres and twelve percent for diffuse. Thirteen of fifty-three cases with suspected ectopic thyroid tissue were positive. Little useful information was obtained in the evaluation of goitre. It is concluded that thyroid scintigraphy was an unnecessary investigation in the evaluation of goitres in euthyroid patients. Its primary role was in the investigation of the solitary nodule, ectopic thyroid tissue and the retresternal goitre. Therefore, only selected patients should be investigated with thyroid scintigraphy

  19. The evaluation of 67Ga-scintigraphy in malignant tumor of the urinary tract

    International Nuclear Information System (INIS)

    Arai, Eishoku; Nishibuchi, Shigeo; Katamura, Eiju

    1982-01-01

    67 Ga-scintigraphy was performed in 40 patients with tumor of the urinary tract (18 with renal cell carcinoma, 4 with renal pelvic cancer, 18 with bladder cancer). In patients with renal cell carcinoma, 67 Ga-scintigraphy was positive in 46% of those with primary lesions, and in 80% of those with metastatic lesions. In those with renal pelvic cancer, two with only a primary lesion had a negative 67 Ga-scintigraphy, and one with both primary and metastic lesions and one with only a metastatic lesion after nephrectomy showed distinctly positive 67 Ga-scintigraphy. Among patients with bladder cancer only 31% with primary lesions only had positive 67 Ga-scintigraphy. In conclusion, 67 Ga-scintigraphy is of little use as a diagnostic aid in primary tumors of the urinary tract, but may be useful in the diagnosis of metastatic lesions. (author)

  20. Diagnosis of pheochromocytoma using (123I)-compared with (131I)-metaiodobenzylguanidine scintigraphy

    International Nuclear Information System (INIS)

    Furuta, Nozomu; Kiyota, Hiroshi; Yoshigoe, Fukuo; Hasegawa, Norio; Ohishi, Yukihiko

    1999-01-01

    Patient with pheochromocytoma (PCT) cannot be cured without operation, therefore, preoperative determination of the localization of PCT should be performed accurately. ( 131 I)-Metaiodobenzylguanidine (MIBG) scintigraphy is a gold standard for the diagnosis of PCT. However, ( 123 I)-MIBG is also found to accumulate in PCT. In order to clarify the usefulness of ( 123 I)-MIBG scintigraphy for the local detection of PCT, we compared the distribution of ( 123 I)- and ( 131 I)-MIBG in patients with or without PCT. ( 131 I)- and ( 123 I)-MIBG scintigraphy was performed in 29 and 16 patients, respectively. In the former group, 14 patients had PCT, 12 had hypertension without any adrenal disorder and three had other diseases. In the latter group, eight patients had PCT, two had hypertension without any adrenal disorder and six had other diseases. The sensitivity, specificity and accuracy of ( 123 I)- with ( 131 I)-MIBG scintigraphy were compared. The sensitivity of ( 131 I)- and ( 123 I)-MIBG scintigraphy was 85.7 and 90%, respectively. The specificity of each test was 100%. The accuracy of ( 131 I)- and ( 123 I)-MIBG scintigraphy was 93.1 and 95%, respectively. The quality of images obtained using ( 123 I)-MIBG was better than with ( 131 I)-MIBG, because ( 123 I)-MIBG generated a higher dose of γ-rays with a higher specificity than ( 131 I)-MIBG. In addition, normal adrenal grands were visualized in 50% of patients tested with ( 123 I)-MIBG scintigraphy. These results indicate that ( 123 I)-MIBG scintigraphy is a valuable tool for the local detection of PCT, as is ( 131 I)-MIBG scintigraphy. Furthermore, it is possible that ( 123 I)-MIBG can be used as an alternative to ( 131 I)-MIBG for the detection of PCT. Our study was not a prospective study and the background of the patients was not matched. Further prospective studies are needed in order to determine the efficacy of ( 123 I)-MIBG scintigraphy for the diagnosis of PCT. (author)

  1. Early diagnosis of morphologic-functional changes of the airways by a simple method of inhalation scintigraphy

    International Nuclear Information System (INIS)

    Flierdt, E. van de; Bauer, R.; Laubenbacher, C.; Didic, M.; Langhammer, H.R.; Pabst, H.W.

    1992-01-01

    In order to validate a method of inhalation scintigraphy with 99m Tc-labeled human serum albumin in the early diagnosis of morphologic-functional changes of the airways 35 volunteers and patients (12 healthy non-smokers and smokers each, 11 patients with bronchitis) were studied. Deposition of the aerosol immediately after inhalation was calculated quantitatively by a ROI technique and qualitatively (scoring of central deposition, homogeneity, and recognizability of lung outline). Additionally, the regional clearance of the inhaled aerosol was determined by continuous lung imaging up to 60 min (mainly regional mucociliary removal rates). Discrimination between healthy volunteers and patients with bronchitis was possible by means of deposition patterns immediately after inhalation. On the other hand, no differences could be recognized in this way between healthy non-smokers and smokers. Regional mucociliary removal was higher in non-smokers than in smokers, but there was no difference between smokers and patients with bronchitis. (orig.) [de

  2. Synthesis of a hollow fiber type porous chelating resin containing the amide oxime group by radiation induced graft polymerization for the uranium recovery

    International Nuclear Information System (INIS)

    Hori, Takahiro; Saito, Kyoichi; Furusaki, Shintaro; Sugo, Takanobu; Okamoto, Jiro.

    1986-01-01

    A hollow fiber type porous chelating resin containing amide oxime as a functional group was synthesized and used as an adsorbent for the recovery of uranium. Hollow fiber type porous polyethylene was used as a base polymer. Acrylonitrile was grafted onto it by the radiation-induced graft polymerization. By changing the reaction time, four kinds of graft polymer were obtained. The degree of grafting ranged from 79 % to 127 %. Each resin was soaked in hydroxylamine solution, and the cyano group was converted to amide oxime group. By elemental analysis, the amount of nitrogen introduced on the graft polymer resin in amidoximation was determined to range from 4.3 mmol to 8.5 mmol per 1 g of base polymer. Most of the nitrogen is considered to belong to the amide oxime group. The pore radius, which was initially distributed broadly from about 500 A to 10000 A for the base polymer, was changed to about 1000 A with narrow distribution by the grafting. The pore volume was 1.2 ∼ 1.4 cm 3 per 1 gram of the amide oxime resin, which was about half of that of the initial base polymer. But the pore volume per 1 g base polymer of the amide oxime resin increased with an increase in the grafting degree, e.g. 4.5 cm 3 /g base polymer at 127 % of grafting degree. Specific surface area, which was 30 m 2 /g in base polymer, decreased with an increase in the grafting degree, e.g. 15 m 2 /g at 127 % of grafting degree. Both the amounts of the adsorbed hydrochloric acid and the adsorbed copper were about 1.5 times of the amount of nitrogen introduced in the amidoximation. The reason is considered to be caused by the formation of hydroxamic acid and amide from the measurements of the IR spectra. The amount of uranium adsorbed on the resin was 64 % of the amount of nitrogen introduced in the amidoximation. (author)

  3. Contribution and advantages of scintigraphy in salivary pathology

    International Nuclear Information System (INIS)

    Naous, Hussein.

    1973-01-01

    Recent technical improvements, especially the use of the scintillation camera, enable kinetic studies to be carried out by isotopic exploration and salivary scintigraphy has become an easy, fast and painless method of functional investigation of the main salivary glands. This work outlines the results obtained by Tc 99m scintigraphy with a scintillation camera, relative to the most important salivary gland diseases. After an account of the anatomy and general pathology of the parotid glands and submaxillaries the chief characteristics of the tracer, the detection techniques and the method employed here are described briefly. The elementary scintigraphic aspects found in the different observations are reported, then discussed in connection with results already published. The conclusion drawn from this work is that it is possible in the vast majority of cases, by comparing and combining the morphological and kinetic study of the salivary glands by technetium 99m scintigraphy with the clinical context, to obtain very valuable information which no other complementary examination has so far been able to supply satisfactorily. Now that scintigraphy has become a method of functional and not only morphological exploration it occupies a vital place in the study of the salivary glands [fr

  4. Extra-osseous uterine pathophysiology demonstrated on skeletal scintigraphy

    International Nuclear Information System (INIS)

    Mansberg, R.; Lewis, G.

    1999-01-01

    Full text: Skeletal scintigraphy is a sensitive procedure for evaluating disease and trauma involving the skeleton. Extra-skeletal pathophysiology is also often demonstrated. This may include uptake by tumours, soft tissue calcification and infection as well as renal pathology. Skeletal scintigraphy is often performed to evaluate hip and back pain and extra-osseous uterine pathophysiology can be demonstrated in both the early and late phases of the study as in the following cases. Three women underwent skeletal scintigraphy for the investigation of low back pain in two patients and post-partum hip pain in one. A large vascular uterus with deviation of the bladder was demonstrated in the post-partum patient. Increased pelvic vascularity and bladder deviation in the second patient was shown by ultrasound to correspond to a left-sided fibroid with associated adenomyosis. In the third case, right-sided pelvic vascularity and left bladder deviation were shown on ultrasound to be due to an anteverted, anteflexed uterus tilted to the right. These cases illustrate the importance of documenting extra-osseous findings on skeletal scintigraphy and the benefits of correlation with anatomical imaging

  5. [Application scintigraphy in evaluation of salivary gland function].

    Science.gov (United States)

    Mojsak, Małgorzata Natalia; Rogowski, Franciszek

    2010-03-01

    The salivary glands belong to the exocrine glands. There are tree main pairs of salivary glands: parotid, submandibular, sublingual. Several modalities are used for salivary gland imaging, such as sonography, computer tomography and magnetic resonance imaging. The aim of these methods is mainly to present morphological impairment. Parenchymal function and excretion function of all salivary glands can be quantified by scintigraphy. After single intravenous injection of 99mTc-pertechnetate sequential images are acquired up to 25-40 minutes. Usually about fifteen minutes postinjection 3 ml of lemon juice are administered intraorally as sialogogue. Salivary scintigraphy can estimate the severity of salivary gland involvement and function disorders, which may not be accurately reflected by the morphological damage. The clinical impact of scintigraphy has been reported in multiple salivary glands diseases, such as Sjogren's syndrome, sialolithiasis with or without parenchymal damage, iatrogenic irradiation of the salivary glands for therapy of head and neck tumors or radioiodine treatment of thyroid cancer. No other method can give so much information about function of salivary glands. Scintigraphy is noninvasive examination, easy to perform, reproducible and well-tolerated by the patient.

  6. Relationship between Ga-67 uptake and radiotherapeutic response of primary lung cancer (squamous cell carcinoma)

    International Nuclear Information System (INIS)

    Higashi, Kotaro; Takase, Shuko; Ohguchi, Manabu; Seki, Hiroyasu; Okimura, Tetsuro; Miyamura, Toshio; Yamamoto, Itaru; Rikimaru, Shigeho.

    1992-01-01

    This investigation was undertaken to evaluate the relationship between Ga-67 uptake and radiotherapeutic response of primary lung cancer (squamous cell carcinoma), Ga-67 uptake of tumor was estimated on 16 patients with untreated primary lung cancer (squamous cell carcinoma). Ga-67 uptake was then compared with the response to radiation therapy (tumor reduction ratio). There was statistically significant inverse correlation between Ga-67 uptake and response to radiation therapy (r=-0.701, p<0.01). The fewer the Ga-67 accumulation in the tumor, the more effective radiotherapy in reducing tumor size. In conclusion, Ga-67 scintigraphy appears to be able to predict the response of primary lung cancer (squamous cell carcinoma) to radiation therapy. (author)

  7. Assessment of hepatic functional reserve for hepatic resection using {sup 99m}Tc-PMT scintigraphy in comparison with {sup 99m}Tc-GSA scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Atsushi [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-03-01

    {sup 99m}Tc-diethylenetriamine-pentaacetic acid-galactosyl human serum albumin({sup 99m}Tc-GSA) scintigraphy has been reported as a useful study of hepatic functional reserve recently. We have performed {sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan({sup 99m}Tc-PMT) and {sup 99m}Tc-GSA preoperatively for evaluation of hepatic functional reserve and compared the usefulness of those scintigraphy study. Twenty-four patients who were the candidates of hepatic resection underwent {sup 99m}Tc-PMT scintigraphy preoperatively. Hepatic blood flow coefficient (K value), the amount of hepatic blood flow (HBF), and the ratio of portal blood flow (PVR) were computed. {sup 99m}Tc-GSA scintigraphy was also performed within two weeks of the {sup 99m}Tc-PMT scintigraphy, and the ratio of disappearance (HH{sub 15}) and the hepatic uptake ratio (LHL{sub 15}) were computed. The relationship between K value, HBF, PVR, HH{sub 15} and LHL{sub 15} was analyzed. Their correlation with other liver function tests was also examined. K value and HBF did not show statistically significant correlations with HH{sub 15} and LHL{sub 15}, PVR correlated statistically significantly HH{sub 15} and LHL{sub 15}. K value correlated with the preoperative values of cholinesterase, Fischer ratio, {gamma}-globulin, ICGR{sub 15}, albumin, and platelet count. There was a statistically significant correlation between LHL{sub 15} and the value of cholinesterase, {gamma}-globulin, platelet count, and Fischer ratio. When the liver resection of subsegmentectomy or more was indicated in 10 patients, nine patients had LHL{sub 15} value less than 0.9 which delineated possibility of poor prognosis. However, judging from K value and HBF, liver resection was considered feasible and it was all successfully performed, resulting in good prognosis. From this study, it is suspected that {sup 99m}Tc-GSA scintigraphy reflect the severity of liver fibrosis and the amount of portal blood flows, and {sup 99m}Tc-PMT scintigraphy

  8. The diagnostic value of bone scintigraphy in patients with low back pain

    International Nuclear Information System (INIS)

    Schuette, H.E.; Park, W.M.

    1983-01-01

    Bone scintigraphy has been studied in two groups of patients presenting with low back pain. In one group of 38 patients suffering ''non-specific'' back pain, bone scintigraphy and laboratory findings were negative in 24. There were abnormal laboratory findings in all of the remaining 14 and 7 had positive bone scans indicative of clinically significant disease. Selection of patients for bone scintigraphy in this group should therefore be influenced by abnormal laboratory findings and elevation of the erythrocyte sedimentation rate in particular. By comparison, the bone scans were reviewed from another group of patients suffering previously known malignancy. Out of 138 patients, nearly 40% showed a positive bone scan due to subsequently proven metastasis. Bone scintigraphy was positive in a further 14% as a result of osteoporotic rib fracture and vertebral body collapse. In half of these, it was not possible to exclude malignancy by scintigraphy. The present findings indicate that bone scintigraphy is not a useful procedure in patients with long-standing low back pain who have normal radiographs and normal laboratory findings. (orig.)

  9. 1H, 13C and 13N chemical shifts and 1H-15N and 13C-15N heteronuclear spin-spin coupling constants n the NMR spectra of 5-substituted furfural oximes

    International Nuclear Information System (INIS)

    Popelis, Yu.Yu.; Liepin'sh, E.E.; Lukevits, E.Ya.

    1986-01-01

    The 1 H, 13 C, and 15 N NMR spectra of 15 N-enriched 5-substituted furfural oximes were investigated. It was shown that the chemical shifts of the ring atoms and the oxime group correlate satisfactorily with the F and R substituent constants, whereas their sensitivity to the effect of the substituents is lower than in monosubstituted furan derivatives. The constants of spin-spin coupling between the ring protons and the oxime group were determined. An analysis of the 1 H- 1 H spin-spin coupling constants (SSCC) on the basis of their stereospecificity indicates that the E isomers have primarily an s-trans conformation in polar dimethyl sulfoxide, whereas the Z isomers, on the other hand, have an s-cis conformation. The signs of the direct and geminal 13 C- 15 N SSCC were determined for 5-trimethylsilylfurfural oxime

  10. Lung allograft rejection in the rat. I. Accelerated rejection caused by graft lymphocytes

    International Nuclear Information System (INIS)

    Prop, J.; Nieuwenhuis, P.; Wildevuur, C.R.

    1985-01-01

    To find out to what extent rejection of lungs differs from that of other organs, functional rejection of lung allografts was studied in five combinations of inbred rat strains. Rejection could be monitored accurately by perfusion scintigraphy, and equally well by chest roentgenography. The rejection of lung grafts was found to proceed remarkably fast, when compared with heart grafts, in combinations with strong RT1-incompatibilities. This accelerated rejection pattern could be converted into rejection at a normal pace by pretreatment of the donor with 10 Gy roentgen irradiation one day before transplantation. Donor pretreatment depleted the lung graft's bronchus-associated lymphoid tissue (BALT) of lymphocytes. When grafts were depleted of all other passenger cells as well--by retransplantation from a cyclosporine-treated intermediate host--they showed an even more reduced immunogenicity, probably because of the loss of donor-type dendritic cells. These results indicate that lymphocytes from the BALT of lung grafts are capable of accelerating the rejection response

  11. Influence of the Different Primary Cancers and Different Types of Bone Metastasis on the Lesion-based Artificial Neural Network Value Calculated by a Computer-aided Diagnostic System,BONENAVI, on Bone Scintigraphy Images

    Directory of Open Access Journals (Sweden)

    TAKURO ISODA

    2017-01-01

    Full Text Available Objective(s: BONENAVI, a computer-aided diagnostic system, is used in bone scintigraphy. This system provides the artificial neural network (ANN and bone scan index (BSI values. ANN is associated with the possibility of bone metastasis, while BSI is related to the amount of bone metastasis. The degree of uptake on bone scintigraphy can be affected by the type of bone metastasis. Therefore, the ANN value provided by BONENAVI may be influenced by the characteristics of bone metastasis. In this study, we aimed to assess the relationship between ANN value and characteristics of bone metastasis. Methods: We analyzed 50 patients (36 males, 14 females; age range: 42–87 yrs, median age: 72.5 yrs with prostate, breast, or lung cancer who had undergone bone scintigraphy and were diagnosed with bone metastasis (32 cases of prostate cancer, nine cases of breast cancer, and nine cases of lung cancer. Those who had received systematic therapy over the past years were excluded. Bone metastases were diagnosed clinically, and the type of bone metastasis (osteoblastic, mildly osteoblastic,osteolytic, and mixed components was decided visually by the agreement of two radiologists. We compared the ANN values (case-based and lesion-based among the three primary cancers and four types of bone metastasis.Results: There was no significant difference in case-based ANN values among prostate, breast, and lung cancers. However, the lesion-based ANN values were the highest in cases with prostate cancer and the lowest in cases of lung cancer (median values: prostate cancer, 0.980; breast cancer, 0.909; and lung cancer, 0.864. Mildly osteoblastic lesions showed significantly lower ANN values than the other three types of bone metastasis (median values: osteoblastic, 0.939; mildly osteoblastic, 0.788; mixed type, 0.991; and osteolytic, 0.969. The possibility of a lesion-based ANN value below 0.5 was 10.9% for bone metastasis in prostate cancer, 12.9% for breast cancer, and 37

  12. Machine learning improves the accuracy of myocardial perfusion scintigraphy results

    International Nuclear Information System (INIS)

    Groselj, C.; Kukar, M.

    2002-01-01

    Objective: Machine learning (ML) an artificial intelligence method has in last decade proved to be an useful tool in many fields of decision making, also in some fields of medicine. By reports, its decision accuracy usually exceeds the human one. Aim: To assess applicability of ML in interpretation of the stress myocardial perfusion scintigraphy results in coronary artery disease diagnostic process. Patients and methods: The 327 patient's data of planar stress myocardial perfusion scintigraphy were reevaluated in usual way. Comparing them with the results of coronary angiography the sensitivity, specificity and accuracy of the investigation were computed. The data were digitized and the decision procedure repeated by ML program 'Naive Bayesian classifier'. As the ML is able to simultaneously manipulate with whatever number of data, all reachable disease connected data (regarding history, habitus, risk factors, stress results) were added. The sensitivity, specificity and accuracy of scintigraphy were expressed in this way. The results of both decision procedures were compared. Conclusion: Using ML method, 19 more patients out of 327 (5.8%) were correctly diagnosed by stress myocardial perfusion scintigraphy. In this way ML could be an important tool for myocardial perfusion scintigraphy decision making

  13. Thyroid scintigraphy for the detection of radiation-induced thyroid cancer

    International Nuclear Information System (INIS)

    Puylaert, J.B.; Pauwels, E.K.; Goslings, B.M.; Van Daal, W.A.

    1985-01-01

    Thyroid scintigraphy with Tc-99m pertechnetate was performed in 249 patients who received radiation therapy for abnormalities in the head or neck in order to determine the role of this examination in the detection of abnormal nodules arising from cancer. These patients received a mean total dose of about 10.1 Gy. The mean follow-up period was 39 years. All patients underwent physical examination without prior knowledge of the scintigram. Scintigrams were evaluated without prior knowledge of the physical examination. In 158 cases, both the physical examination and scintigraphy were negative. In 64 cases, both examinations were positive. In ten patients, the physical examination was positive and scintigraphy was negative and vice versa in 17 patients. Of 249 patients, 28 ultimately underwent thyroid surgery; a total of four had carcinoma. A cost-benefit relationship as to routine scintigraphy as a screening procedure is presented. If patients are first screened by palpation, a number of abnormal nodules will be missed. In addition, a considerable number with positive palpation would probably undergo surgery unnecessarily. From a clinical and financial point of view, it is believed that scintigraphy is the examination of choice for screening for radiation-induced thyroid malignancies

  14. Clinical diagnostic potentials of thyroid ultrasonography and scintigraphy; An evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Torizuka, Tatsuo; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Konishi, Junji (Kyoto Univ. (Japan). Hospital); Endo, Keigo

    1993-06-01

    This prospective study was designed to evaluate the potential contributions of high resolution ultrasonography (US) and Tc-99m scintigraphy in the routine diagnosis of thyroid disease. The diagnostic impacts of US and Tc-99m scintigraphy results in 177 patients visiting our thyroid clinic were assessed and scored according to the following criteria: when the information provided by either test supported, confirmed or changed the initial clinical diagnosis, they received scores of 2, 3 and 4 respectively, while score 1 was given when the test itself was useless for the differential diagnosis. US identified focal lesions that both palpation and scintigraphy had failed to detect in 14 (12.1%) of 116 patients with diffuse thyroid diseases, suggesting the necessity of Hashimoto's thyroiditis, adenoma, adenocarcinoma and adenomatous goiter, and vice versa in the diagnosis of hyperthyroid and euthyroid Graves's diseases. Thus, the advantages of US over scintigraphy for morphological evaluation were confirmed. US was particularly useful for the differential diagnosis of adenomatous goiter from Hashimoto's thyroiditis or a single nodular disease. In contrast, scintigraphy gave functional images, being especially helpful for the differential diagnosis of thyrotoxicosis. (author).

  15. Lung transplantation in the rat. III. Functional studies in iso- and allografts

    International Nuclear Information System (INIS)

    Marck, K.W.; Prop, J.; Wildevuur, C.R.

    1983-01-01

    Recently a microsurgical technique for orthotopic left lung transplantation in the rat was developed. The aim of this study was to investigate the influence of the operation itself and of an unmodified rejection reaction on the function of the transplanted rat lung. Orthotopic left lung transplantation was performed in 59 rats (34 isografts and 25 allografts). Isografts demonstrated a mean left lung perfusion of 23.1% in the first two postoperative weeks. Seven out of the 10 animals, subjected to a repeated scintigraphy 5-10 weeks later, had an increased graft perfusion, resulting in an almost normal mean left lung perfusion of 34.8%. At that time chest roentgenography revealed a good aeration of the grafts, that at autopsy had a normal aspect. Allografts showed an initial mean left lung perfusion (24.6%) similar to the isografts, which, however, declined sharply a few days later (4.3%). At that time chest roentgenography revealed totally opalescent grafts that at autopsy had the hepatized aspect characteristic of lung allograft rejection. These results of isogeneic and allogeneic lung transplantation in the rat were comparable with those of canine auto- and allotransplantation. For immunogenetic and economical reasons lung transplantation in the rat is a good alternative animal model in lung transplantation research

  16. Kinetic analysis of interactions of paraoxon and oximes with human, Rhesus monkey, swine, rabbit, rat and guinea pig acetylcholinesterase.

    Science.gov (United States)

    Worek, Franz; Aurbek, Nadine; Wille, Timo; Eyer, Peter; Thiermann, Horst

    2011-01-15

    Previous in vitro studies showed marked species differences in the reactivating efficiency of oximes between human and animal acetylcholinesterase (AChE) inhibited by organophosphorus (OP) nerve agents. These findings provoked the present in vitro study which was designed to determine the inhibition, aging, spontaneous and oxime-induced reactivation kinetics of the pesticide paraoxon, serving as a model compound for diethyl-OP, and the oximes obidoxime, pralidoxime, HI 6 and MMB-4 with human, Rhesus monkey, swine, rabbit, rat and guinea pig erythrocyte AChE. Comparable results were obtained with human and monkey AChE. Differences between human, swine, rabbit, rat and guinea pig AChE were determined for the inhibition and reactivation kinetics. A six-fold difference of the inhibitory potency of paraoxon with human and guinea pig AChE was recorded while only moderate differences of the reactivation constants between human and animal AChE were determined. Obidoxime was by far the most effective reactivator with all tested species. Only minor species differences were found for the aging and spontaneous reactivation kinetics. The results of the present study underline the necessity to determine the inhibition, aging and reactivation kinetics in vitro as a basis for the development of meaningful therapeutic animal models, for the proper assessment of in vivo animal data and for the extrapolation of animal data to humans. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  17. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S. [Centro de Diagnostico Fleury, Sao Paulo, SP (Brazil). Secao de Medicina Nuclear; Sao Paulo Univ. (USP), SP (Brazil). Escola de Saude Publica. Dept. de Epidemiologia]. E-mail: paulo.duarte@fleury.com.br

    2006-07-15

    Objective: The aim of this study was to compare the renal function measured with either {sup 99m}Tc-DTPA or {sup 99m}Tc-EC dynamic scintigraphies with that measured using {sup 99m}Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with {sup 99m}Tc-DTPA (55 studies) or with {sup 99m}Tc-EC (56 studies) were compared with the relative function measured using {sup 99m}Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of {sup 99m}Tc-DTPA and {sup 99m}Tc-EC studies that presented relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with {sup 99m}Tc-EC is not statistically different from that measured with {sup 99m}Tc-DMSA (p = 0.97). The relative renal function measured with {sup 99m}Tc-DTPA was statistically different from that measured using {sup 99m}Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA is higher for the {sup 99m}Tc-DTPA scintigraphy (p 0.04) than for {sup 99m}Tc-EC. Conclusion: the relative renal function measured with {sup 99m}Tc-EC dynamic scintigraphy is comparable with that measured with {sup 99m}Tc-DMSA static scintigraphy, while the relative renal function measured with {sup 99m}Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with {sup 99m}Tc-DMSA static scintigraphy. (author)

  18. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    International Nuclear Information System (INIS)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S.; Sao Paulo Univ.

    2006-01-01

    Objective: The aim of this study was to compare the renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured using 99m Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99m Tc-DTPA (55 studies) or with 99m Tc-EC (56 studies) were compared with the relative function measured using 99m Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of 99m Tc-DTPA and 99m Tc-EC studies that presented relative renal function different by more than 5% from that measured with 99m Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with 99m Tc-EC is not statistically different from that measured with 99m Tc-DMSA (p = 0.97). The relative renal function measured with 99m Tc-DTPA was statistically different from that measured using 99m Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with 99m Tc-DMSA is higher for the 99m Tc-DTPA scintigraphy (p 0.04) than for 99m Tc-EC. Conclusion: the relative renal function measured with 99m Tc-EC dynamic scintigraphy is comparable with that measured with 99m Tc-DMSA static scintigraphy, while the relative renal function measured with 99m Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with 99m Tc-DMSA static scintigraphy. (author)

  19. Gated equilibrium bloodpool scintigraphy

    International Nuclear Information System (INIS)

    Reinders Folmer, S.C.C.

    1981-01-01

    This thesis deals with the clinical applications of gated equilibrium bloodpool scintigraphy, performed with either a gamma camera or a portable detector system, the nuclear stethoscope. The main goal has been to define the value and limitations of noninvasive measurements of left ventricular ejection fraction as a parameter of cardiac performance in various disease states, both for diagnostic purposes as well as during follow-up after medical or surgical intervention. Secondly, it was attempted to extend the use of the equilibrium bloodpool techniques beyond the calculation of ejection fraction alone by considering the feasibility to determine ventricular volumes and by including the possibility of quantifying valvular regurgitation. In both cases, it has been tried to broaden the perspective of the observations by comparing them with results of other, invasive and non-invasive, procedures, in particular cardiac catheterization, M-mode echocardiography and myocardial perfusion scintigraphy. (Auth.)

  20. The effects of aminophylline infusion in the treatment of children with acute asthma exacerbation. Evaluation with {sup 81m}Kr ventilation scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, Yasuko; Shimada, Takao [Jikei Univ., Tokyo (Japan). School of Medicine

    1998-09-01

    The use of intravenous aminophylline in the treatment of children with acute asthma remains controversial. Most authors suggest that aminophylline be used with caution because of its poor efficacy with adverse reactions and instead recommend other drugs, such as {beta}{sub 2}-adrenergic agonists and glucocorticoids. However other studies have reported the benefits of aminophylline, and current Japanese guidelines for the management of asthma recommend its use. Here, we have evaluated the efficacy of aminophylline infusion in children with acute asthma exacerbations. Twenty children with acute asthma exacerbations were given an infusion of 5 mg/kg of aminophylline over 5 minutes, 30 minutes after the same volume of normal saline had been infused as a control. {sup 81m}Kr ventilation scintigraphy was done sequentially, and lung function was measured with spirometry before and after each infusion. Side effects were also evaluated with a questionnaire. Ventilation images obtained with {sup 81m}Kr scintigraphy, which initially showed widespread ventilatory defects caused by bronchoconstriction, decreased 54.9% after aminophylline infusion (p<0.0001). Ventilatory defects, caused by both central and peripheral airway disturbances and confirmed with the {sup 81m}Kr bolus inhalation procedure, also showed significant improvement (p<0.0001). These improvement were accompanied by improvements in lung function as assessed with forced expiratory volume in 1 second (p<0.01) and maximum expiratory flow rates at 25% (p<0.001) and 50% (p<0.001). No serious adverse reactions were recognized in any subjects. Our results show that aminophylline is a useful bronchodilator which decreased ventilatory imbalance and improves lung function in both central and peripheral airways. (author)

  1. Extraosseus enrichments in bone scintigraphy

    International Nuclear Information System (INIS)

    Jochens, R.; Schumacher, T.; Amthauer, H.; Wolter, M.; Stock, W.; Stroszczynski, C.; Moersler, J.P.; Eichstaedt, H.

    1996-01-01

    Extraosseus enrichments are common findings in bone scintigraphy. Main causes are artifacts by skin or cloth contamination, paravenous and subcutaneous injection. Physical examination, removal of cloths, skin cleaning or further images in differing projections lead to the correct diagnosis artefact or extraosseous enrichments. Further on, extraosseous enrichments are seen in physiological variants. In different diseases extraosseous enrichments are common, especially in urinary tract, liver and extremities. Further diagnostics, e.g. conventional radiologic procedures, sonography and CT scans, have to be performed. In individual cases side results in bone scintigraphy lead to formerly unknown diagnosis, further diagnostic procedure is influenced decisively. Own cases show for example a cerebral apoplectic insult, formerly unknown liver metastasis or metastasis in extraosseous Ewings's sarcoma. (orig.) [de

  2. [sup 99m]Tc-RBC subtraction scintigraphy; Assessmet of bleeding site and rate

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru (Toyama Medical and Pharmaceutical Univ. (Japan). Hospital)

    1994-03-01

    Sequential abdominal scintigrams with [sup 99m]Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author).

  3. I-123 IMP brain scintigraphies in asphyxiated newborns

    International Nuclear Information System (INIS)

    Maeda, Hisatoshi; Konishi, Yukuo; Kuriyama, Masanori; Ishii, Yasushi; Sudo, Masakatsu

    1987-01-01

    Brain scintigraphies with N-Isopropyl (I-123) p-Iodoamphetamine (I-123 IMP) were conducted in eight patients who had asphyxia at the time of birth. Two patients, 15 and 26 year-old, had local defects and diffuse low cerebral uptakes. Two children, 70 day and 2 year-old, had no cerebral uptake. Brain scintigraphies were carried out twice in three among four newborns. Only slight I-123 IMP brain uptakes were observed in the first 10 days. The lateral views of the brain scintigraphies showed increased uptake in the middle region of the brain between 10 to 30 days and reached almost equally distributed in frontal, middle and posterior regions after 30 days. These results were thought to represent rather developmental changes of the cerebral blood flow after ischemic attacks at birth. (author)

  4. Docking and molecular dynamics studies of peripheral site ligand–oximes as reactivators of sarin-inhibited human acetylcholinesterase

    NARCIS (Netherlands)

    Almeida, J.S.F.D. de; Cuya Guizado, T.R.; Guimarães, A.P.; Ramalho, T.C.; Gonçalves, A.S.; Koning, M.C. de; França, T.C.C.

    2016-01-01

    In the present work, we performed docking and molecular dynamics simulations studies on two groups of long-tailored oximes designed as peripheral site binders of acetylcholinesterase (AChE) and potential penetrators on the blood brain barrier. Our studies permitted to determine how the tails anchor

  5. Pulmonary perfusion scintigraphy in the evaluation of the severity of bronchopulmonary dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Soler, C. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain); Figueras, J. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain)]|[Servicio de Neonatologia, Hospital Clinico, Barcelona (Spain); Roca, I. [Nuclear Medicine Unit, Autonomous Univ. of Barcelona (Spain); Perez, J.M. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain); Jimenez, R. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain)

    1997-01-01

    Objective. The objectives of this study were to analyze the changes in pulmonary perfusion in bronchopulmonary dysplasia (BPD) and to assess the advantages of this method in evaluating the severity of BPD. Patients and methods. The study group was made up of 10 children with BPD, matched with a control group of 12 children. The criteria for matching were birth weight, gestational age and need for ventilation for more than 3 days. Clinical and roentgenographic scoring systems were applied on the 21st day of life. At 6 months of corrected age, clinical evolutive severity was evaluated and a pulmonary perfusion scintigraphy using technetium-99 was performed in each child. The scintigraphic findings were classified in five categories ranging from normal to severely affected, depending on the degree and localization of perfusion abnormalities. Another score was obtained by assigning a value from 1 to 5 to each pulmonary lobe, depending on the concentration of the tracer. Results. The study of clinical, roentgenographic and evolutive scores always showed higher values in children with BPD, with good correlation between methods (P < 0.001). In the BPD group, abnormal lung perfusion patterns were more frequent and more severe (P < 0.05), the lobe scoring was higher (P < 0.05), and a lower count rate was found (P < 0.01). Conclusion. Pulmonary scintigraphy is a useful technique in evaluating the severity of BPD. (orig.). With 1 fig., 3 tabs.

  6. Pulmonary perfusion scintigraphy in the evaluation of the severity of bronchopulmonary dysplasia

    International Nuclear Information System (INIS)

    Soler, C.; Figueras, J.; Roca, I.; Perez, J.M.; Jimenez, R.

    1997-01-01

    Objective. The objectives of this study were to analyze the changes in pulmonary perfusion in bronchopulmonary dysplasia (BPD) and to assess the advantages of this method in evaluating the severity of BPD. Patients and methods. The study group was made up of 10 children with BPD, matched with a control group of 12 children. The criteria for matching were birth weight, gestational age and need for ventilation for more than 3 days. Clinical and roentgenographic scoring systems were applied on the 21st day of life. At 6 months of corrected age, clinical evolutive severity was evaluated and a pulmonary perfusion scintigraphy using technetium-99 was performed in each child. The scintigraphic findings were classified in five categories ranging from normal to severely affected, depending on the degree and localization of perfusion abnormalities. Another score was obtained by assigning a value from 1 to 5 to each pulmonary lobe, depending on the concentration of the tracer. Results. The study of clinical, roentgenographic and evolutive scores always showed higher values in children with BPD, with good correlation between methods (P < 0.001). In the BPD group, abnormal lung perfusion patterns were more frequent and more severe (P < 0.05), the lobe scoring was higher (P < 0.05), and a lower count rate was found (P < 0.01). Conclusion. Pulmonary scintigraphy is a useful technique in evaluating the severity of BPD. (orig.). With 1 fig., 3 tabs

  7. 99Tcm-MIBI hepatobiliary scintigraphy in peadiatric patients with severe cholestatic infant hepatitis syndrome

    International Nuclear Information System (INIS)

    Chen Guibing; Huang Jinxiong; He Xiaojiang; Luo Zuoming; Lu Zhengyuan; Wu Hua

    2010-01-01

    Objective: Because of the limited of 99 Tc m -diethyl iminodiacetic acid ( 99 Tc m -EHIDA) hepatobiliary scintigraphy in the diagnosis of severe cholestatic infant hepatitis syndrome, trial use 99 Tc m -methoxy isobutyl isonitrile ( 99 Tc m -MIBI) as a new hepatobiliary scintigraphy imaging agent to understand its applied basis and primary evaluate value in diagnosis of severe cholestatic infant hepatitis syndrome. Methods: constructed choledochal atresia animal model and investigated the application basis of 99 Tc m -MIBI hepatobiliary scintigraphy. Twenty-seven children patients of severe cholestatic who finally confirmed infant hepatitis syndrome were underwent firstly 99 Tc m -EHIDIA hepatobiliary scintigraphy. After 24 h delay imaging next day, 99 Tc m -MIBI hepatobiliary scintigraphy was underwent after 1 h. Two imaging agents of value in the diagnosis of severe cholestatic infant hepatitis syndrome were compared. Results: It was proved that 99 Tc m -MIBI was surely excreted by hepatobiliary and had no intestinal autocrine phenomenon in animal test. So 99 Tc m -MIBI can be used to undergo hepatobiliary scintigraphy. The sensitivity of 99 Tc m -MIBI hepatobiliary scintigraphy in the diagnosis of severe cholestatic infant hepatitis syndrome was 100% in our primary clinical study. Its sensitivity was higher than which of 99 Tc m -EHIDA hepatobiliary scintigraphy (66.67%) by far. Conclusion: With regard to those children patients who suspected highly severe cholestatic infant hepatitis syndrome in clinical, the sensitivity of 99 Tc m -MIBI hepatobiliary scintigraphy is obviously superior to conventional 99 Tc m -EHIDA hepatobiliary scintigraphy. (authors)

  8. 131I-19-iodocholesterol scintigraphy and suprarenal pathology

    International Nuclear Information System (INIS)

    Leger, F.A.; Baulieu, J.L.; Plouin, P.F.

    The methods used and results obtained by 131 I-19-iodocholesterol scintigraphy (dose 2mCi) are given for 24 patients with various kinds of suprarenal hyperactivity (primary hyperaldosteronism, Cushing's syndrome, malignant adrenocortical tumour, pheochromocytoma). The morphological and quantitative aspects of suprarenal scintigraphy are examined. A technique to determine the iodocholesterol uptake ratio of the two adrenal glands, considered more important than the fixation rate of each is described [fr

  9. Gallium-67 scintigraphy in borderline lepromatous leprosy

    International Nuclear Information System (INIS)

    Mouratidis, B.; Lomas, F.E.

    1993-01-01

    A middle aged woman with a pyrexia of unknown origin was shown to have borderline lepromatous leprosy. Early gallium-67 scintigraphy demonstrated increased uptake in the subcutaneous tissues of the face and thighs. As a result of these findings skin biopsy was obtained from the right thigh which gave a diagnosis of borderline lepromatous leprosy. The authors have been unable to find other reports of gallium-67 scintigraphy in leprosy but the pattern of gallium-67 distribution should suggest the diagnosis. 5 refs., 1 fig

  10. Scintigraphy of parathyroids in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Hublo, D.; Beauchat, V.; Pattou, F.; Lecomte-Houcke, M.; Prangere, T.; Ziegels, P.; Carnaille, B.; Proye, C.; Marchandise, X.; Steiling, M.

    1997-01-01

    Use of pre-surgery imaging of parathyroids is still questioned. The goal of this study is to evaluate the sensitivity of the scintigraphy in the detection of secondary parathyroid anomalies with renal insufficiency. Thirty two patients (20 F, 12 M) of 14 - 74 years old were operated of secondary hyperparathyroidism with renal insufficiency. It was a matter of re-intervention in 9 cases. The acquisitions were achieved 20 min and 2 h after injection of 550 MBq of MIBI- 99m Tc or of Tetrofosmine - 99m Tc and 2 h after injection of 5.5 MBq of iodine 123. Eighty seven glands of 28 to 3820 mg were pulled out in 23 first surgeries while the parathyroid tissue was found in thymic prolongations in 5 of these patients. The masses of 41 glands, positive by scintigraphy (from 69 to 3829 mg), were significantly higher (Wilcoxon's test, p -8 ) than the 46 not-seen (from 28 to 1050 mg). The sensitivity of total detection is 47%, of 85% for the 33 glands of 500 mg or more and of 24% for the 54 glands of less than 500 mg. In 9 re-interventions, 12 abnormal glands were pulled out: 11 (of 430 to 4500 mg were positive by scintigraphy, while only one gland of 80 mg was not seen. In conclusion, the scintigraphy realised before first surgery for secondary hyperparathyroidism with renal insufficiency presents low sensitivity, related partly, at least, to the low mass of glands and justifies itself only by search for positive ectopic parathyroids. Instead, it appears performing and indispensable in case of re-intervention

  11. Lung scintigraphy with nonspecific human immunoglobulin G (99mTc-HIG) in the evaluation of pulmonary involvement in connective tissue diseases: correlation with pulmonary function tests (PFTs) and high-resolution computed tomography (HRCT)

    International Nuclear Information System (INIS)

    Kostopoulos, C.; Toubanakis, C.; Mamoulakis, C.; Gialafos, E.; Mavrikakis, M.; Koutsikos, J.; Zerva, C.; Leondi, A.; Moulopoulos, L.A.; Sfikakis, P.P.

    2008-01-01

    In patients with connective tissue diseases (CTD), the early detection and evaluation of the severity of the pulmonary involvement is mandatory. High-resolution computed tomography (HRCT) and pulmonary function tests (PFTs) are considered to be valuable noninvasive diagnostic modalities. Radiopharmaceuticals have also been used for this purpose. Our aim was the evaluation of technetium-labeled human polyclonal immunoglobulin G (HIG) lung scintigraphy in the early detection and assessment of the severity of the pulmonary involvement in CTD patients. Fifty-two nonsmoking CTD patients were studied by PFTs, HRCT, and HIG. According to PFTs, patients were divided in group A (impaired PFTs - abnormal pulmonary function) and group B (normal pulmonary function). Semiquantitative analysis was done on HIG and HRCT and corresponding scores were obtained. Significant difference was found between HIG scores in the two groups (0.6 ± 0.07 vs 0.51 ± 0.08, P < 0.001). There was a statistically significant negative correlation between HIG scores and PFTs results and a positive correlation between HIG and HRCT scores. HIG demonstrated similar clinical performance to HRCT. At the best cut-off levels of their score (0.56 and 7, respectively), HIG had a superior sensitivity (77.5 vs 57.5%) with lower specificity (75 vs 91.7%). The combination of the two methods increased the sensitivity of abnormal findings at the expense of specificity. HIG scintigraphy can be used in the early detection and evaluation of the severity of the pulmonary involvement in CTD, whereas, when used in combination with HRCT, the detection of affected patients can be further improved. (orig.)

  12. Evaluation of pentavalent Tc-99m DMSA scintigraphy in small cell and nonsmall cell lung cancers

    International Nuclear Information System (INIS)

    Atasever, T.; Guendogdu, C.; Vural, G.; Kapucu, L.Oe.; Karalezli, A.; Uenlue, M.

    1997-01-01

    Aim: The purpose of this study was to evaluate the clinical usefulness of Tc-99m (V) DMSA in patients suspected of lung cancer and determine whether this agent may have value in differentiation between small cell (SCLC) and non-small cell (NSCLC) lung carcinoma. Methods: Thirty-six patients with clinical and radiological suspicion of primary lung carcinoma were injected 450-600 MBq of Tc-99m (V) DMSA intravenously. Whole body and planar anterior, posterior thorax images were obtained 4-5 h after injection of the radioactive complex. Results: Histopathological results confirmed 23 NSCLC, 10 SCLC and 1 metastatic lung carcinoma and 2 lung abscess. Nineteen of the 23 (82%) NSCLC and all of the 10 (100%) SCLC cases showed Tc-99m (V) DMSA uptake. Single metastatic lung cancer also accumulated radiotracer. Lung abscess did not show uptake. Lesion/Nonlesion (L/N) ratio of SCLC (1.59±0.32) and NSCLC (1.43±0.19) tumour types did not show statistical difference (p>0.05). Tc-99m (V) DMSA whole body imaging also showed bone metastases. Conclusion: Tc-99m (V) DMSA is a noninvasive and cheap imaging method to detect malignant lung cancers and their bone metastases but, differentiation of SCLC and NSCLC is not possible. (orig.) [de

  13. Steric control of reactivity: formation of oximes, benzodiazepinone N-oxides and isoxazoloquinolinones

    OpenAIRE

    Heaney, Frances; Bourke, Sharon; Cunningham, Desmond; McArdle, Patrick

    1998-01-01

    Reaction of the alkenyl carbonyl compounds 1 with hydroxylamine can lead to the formation of the oximes 2, the benzodiazepinone N-oxides 3 or the isoxazoloquinolinones 5. The product(s) of reaction are shown to depend on the electronic nature of the terminal olefinic substituent R3 and the space filling capacity of the substituents R1, R2 and R4. When the olefinic centre is electron poor (R3 = CO2Et) ketocarbonyls convert exclusively to bicyclic nitrones 3 whereas aldehydes are more sensitive...

  14. Ytterbium 169 citrate in the diagnosis of lung opacities of cancerous origin

    International Nuclear Information System (INIS)

    Peltier, Patrick.

    1976-01-01

    Lung scintigraphy for tumour exploration has been widely studied for some years, but unfortunately with the many radioisotopes used at present this examination is not entirely reliable. It seemed interesting therefore to investigate a new tracer, 169 Yb citrate, the properties of which were demonstrated recently by HISADA. To estimate the specificity of this tracer we chose 62 records of different bronchopulmonary diseases. After an introductory review of various diagnostic methods the physical and physiological characteristics of ytterbium citrate and its method of use are described, then the records examined are presented and our thoughts and conclusions discussed. 169 Yb citrate possesses excellent biophysical properties for tumour scintigraphy but this isotope, though causing no radioactive pollution, delivers an appreciable irradiation dose to the patient examined. It has a positive tropism for pathological lung images. The fixation index of the documents taken separately, apart from that of the 14th day, cannot distinguish between benign and malignant diseases. This is possible with the kinetic uptake curve and the index ratios for the 2nd and 14th days. With these diagnostic criteria the overall results are better than those obtained with other commonly used radioisotopes: true positives 70%, false negatives 11%, false positives 4.5% [fr

  15. Scintigraphy usefulness in the diagnosis of visceral candidiasis

    International Nuclear Information System (INIS)

    Ythier, H.; Legghe, R.; Foucher, C.

    1987-01-01

    From the features of two cases, the authors stress the usefulness of the scintigraphy as regards to the diagnosis of visceral candidial abscesses. Such fungal localisations are not unfrequent, especially in immunodeficient patients (haematologic malignancies undergoing chemotherapy, lupus, serious visceral illness...). The positive diagnosis is uneasy because of non-specific clinical features and frequent negative blood cultures. Splenic localisation is the most likely. Citrate Gallium scintigraphy together with splenic labelled RBC scan enables us to give a precise view of the splenic involvment and even of the abdominal extension of the fungal abscess. From the literature review and these two cases, the excellent adequacy of the scintigraphy to the follow-up of systemic candidiasis is underlined and is compared to other usual morphological studies such as US scan and CT examination. In both cases, the diagnosis is fully confirmed by mycological examination [fr

  16. Scintigraphy usefulness in the diagnosis of visceral candidiasis

    Energy Technology Data Exchange (ETDEWEB)

    Ythier, H; Legghe, R; Foucher, C

    1987-01-01

    From the features of two cases, the authors stress the usefulness of the scintigraphy as regards to the diagnosis of visceral candidial abscesses. Such fungal localisations are not unfrequent, especially in immunodeficient patients (haematologic malignancies undergoing chemotherapy, lupus, serious visceral illness...). The positive diagnosis is uneasy because of non-specific clinical features and frequent negative blood cultures. Splenic localisation is the most likely. Citrate Gallium scintigraphy together with splenic labelled RBC scan enables us to give a precise view of the splenic involvment and even of the abdominal extension of the fungal abscess. From the literature review and these two cases, the excellent adequacy of the scintigraphy to the follow-up of systemic candidiasis is underlined and is compared to other usual morphological studies such as US scan and CT examination. In both cases, the diagnosis is fully confirmed by mycological examination.

  17. Computed tomography of hepatocellular carcinoma. Comparison with scintigraphy and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Kuniyuki; Nakata, Hajime; Honda, Hiroshi [University of Occupational and Environmental Health, Kitakyushu, Fukuoka (Japan)

    1983-09-01

    The detectability of hepatocellular carcinoma by computed tomography (CT) was evaluated on 76 cases. The detectability by plain CT was 93% with only slight improvement following a drip infusion of contrast medium. A comparison of scintigraphy, ultrasonography, and CT was also done on 63 cases. From the standpoint of the overall detectability of the tumor, CT was as good as ultrasonography or scintigraphy. Several cases were positive only on either CT or ultrasonography but no case was positive on scintigraphy alone. We believe that the combination of CT and ultrasonography is the most reliable as the screening method.

  18. Parathyroid Scintigraphy in Renal Hyperparathyroidism

    Science.gov (United States)

    Taïeb, David; Ureña-Torres, Pablo; Zanotti-Fregonara, Paolo; Rubello, Domenico; Ferretti, Alice; Henter, Ioline; Henry, Jean-François; Schiavi, Francesca; Opocher, Giuseppe; Blickman, Johan G.; Colletti, Patrick M.; Hindié, Elif

    2015-01-01

    Secondary hyperparathyroidism (sHPT) is a major complication for patients with end-stage renal disease on long-term hemodialysis or peritoneal dialysis. When the disease is resistant to medical treatment, patients with severe sHPT are typically referred for parathyroidectomy (PTx), which usually improves biological parameters as well as clinical signs and symptoms. Unfortunately, early surgical failure with persistent disease may occur in 5%–10% of patients and recurrence reaches 20%–30% at 5 years. Presently, the use of parathyroid scintigraphy in sHPT is usually limited to the management of surgical failures after initial PTx. This review describes the strengths and limitations of typical 99mTc-sestamibi imaging protocols, and highlights the potential benefits of using parathyroid scintigraphy in the initial workup of surgical patients. PMID:23751837

  19. Diagnostic value of (111)In-granulocyte scintigraphy in patients with fever of unknown origin

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Lebech, Anne-Mette

    2002-01-01

    111In-granulocyte scintigraphy is often used as a diagnostic tool in patients with fever of unknown origin (FUO). However, its diagnostic performance has been studied in only a limited number of investigations, with most having been published more than 10 y ago; in addition, a broad range...... of sensitivities and specificities has been reported. Therefore, the aim of this study was to investigate the diagnostic value of granulocyte scintigraphy in patients fulfilling the criteria of FUO. Also studied was whether increased peripheral leukocyte count or C-reactive protein (CRP) level could be used...... to select patients for scintigraphy to raise the diagnostic value. METHODS: For 31 patients with true FUO who underwent granulocyte scintigraphy at a third-line referral hospital between 1995 and 2000, the files and scintigraphy findings were reviewed retrospectively to test the ability of scintigraphy...

  20. Indium 111 leucocyte scintigraphy in abdominal sepsis

    International Nuclear Information System (INIS)

    Baba, A.A.; McKillop, J.H.; Gray, H.W.; Cuthbert, G.F.; Neilson, W.; Anderson, J.R.

    1990-01-01

    We have studied the clinical utility of indium 111 autologous leucocyte scintigraphy retrospectively in 45 patients presenting with suspected intra-abdominal sepsis. The sensitivity was 95% (21/22) and the specificity was 91% (21/23). Some 34 of the studies (17 positive and 17 negative) were considered helpful in furthering patient management (76%) and 8, unhelpful (18%). In 3, the study results were misleading and led to inappropriate treatment. Indium 111 scintigraphy, whether positive or negative, provides information in patients with suspected intra-abdominal sepsis upon which therapeutic decisions can be based. (orig.)

  1. Establishment of A Novel Chinese Human Lung Adenocarcinoma Cell Line CPA-Yang3 and Its Real Bone Metastasis Clone CPA-Yang3BM in Immunodeficient Mice

    Directory of Open Access Journals (Sweden)

    Shunfang YANG

    2011-02-01

    Full Text Available Background and objective The recurrence and metastasis of lung cancer is a tough problem worldwide. The aim of this study is to establish a novel Chinese lung adenocarcinoma cell line and its real bone-seeking clone sub-line for exploring the molecular mechanism of lung cancer metastasis. Methods The cells came from the pleural effusion of a sixtyfive years old female patient with lung adenocarcinoma and supraclavicular lymph node metastases. The gene expression was detected by real-time quantitative PCR. Intracardiac injection of the cells into nude mice was performed and in vivo imaging was obtained by bone scintigraphy and conventional radiography. Bone metastases were determined on bone scintigraphy and then the lesions were resected under deep anesthesia for bone metastasis cancer cell culture. The process was repeated for four cycles to obtain a real bone-seeking clone. Results The tumorigenesis rate started at 4th passage in immunodeficient mice via subcutaneously and as well as later passages. Approximately 1×106 cancer cells were injected into left cardiac ventricle of immunodeficient mice resulted bone metastasis sites were successfully revealed by bone scintigraphy and pathological diagnosis, the mandible (100%, scapula (33%, humerus (50%, vertebral column (50%, femur (66.7% and accompanied invasion with other organs, the adrenal gland (17%, pulmonary (33%, liver (50%, submaxillary gland (33% in the mice after inoculation two-three weeks. The chromosome karyotype analysis of the cells was subdiploid. Quantitative real-time PCR was used to examined and compared with SPC-A-1 lung adenocarcinoma, ESM1, VEGF-C, IL-6, IL-8, AR, SVIL, FN1 genes were overexpress. The novel cell was named CPA-Yang3. The femur metastasis cell was repeated in vivo-in vitro-in vivo with three cycles and harvested a real bone metastasis clone. It was named CPA-Yang3BM. Conclusion Tne characteristics of novel strain CPAYang3 is a highly metastasis cell line of

  2. Static and dynamic scintigraphy in radioisotope cardiology diagnostics

    International Nuclear Information System (INIS)

    Waligorski, M.; Zolna, J.; Strzelecki, A.; Pasyk, S.

    1981-01-01

    A review of the applications of scintigraphy in cardiac diagnosis is given. The principle of operation of the gamma-camera and of the scintigraphic system, the handling of data and the so-called gated scintigraphy are discussed. Characteristics of some radioisotopes applied in nuclear cardiology are given. The most frequent clinical states are discussed in which isotope diagnostics may be useful. Attention is drawn to the advantages of nuclear cardiology methods over conventional diagnostics. (author)

  3. Osseous scintigraphy and auxiliary graft

    International Nuclear Information System (INIS)

    Khelifa, F.; Siles, S.; Puech, B.

    1992-01-01

    The scintigraphy could be a good way to survey the osseous graft: three cases are studied in which were recognized the presence of a graft, surinfection, graft lysis, pseudo-arthrosis, algodystrophy. 8 refs., 5 figs

  4. Double-phase parathyroid 99Tcm-MIBI scintigraphy in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Liu Wei; Xu Zhaoqiang; Hu Jianmin; Chang Guojun; Yao Weixuan; Li Yongjun; Chen Jianwei

    1999-01-01

    Objective: To evaluate the diagnostic value of double-phase parathyroid 99 Tc m -MIBI scintigraphy in secondary hyperparathyroidism (SHP) following chronic renal failure. Methods: 99 Tc m -MIBI parathyroid scintigraphy was performed on 20 SHP patients. All images were analyzed with parathyroid/thyroid ratio (PT/T) and parathyroid index (PTI). 3 patients underwent parathyroidectomy and ectopic autografting. Results: 8 patients were 99 Tc m -MIBI-positive. 9 parathyroid glands removed from 3 patients were histopathologically diagnosed as parathyroid hyperplasia. 8 of the 9 were scintigraphy positive with the sensitivity of 88.9%, the localization of the parathyroids with scanning before operation was accurate. It was found that there were 3 types of MIBI washout in hyperplastic parathyroids. Conclusions: 99 Tc m -MIBI scintigraphy is valuable in localization of parathyroids in SHP, especially of hyperfunctioning glands. Special attention should be paid to the fact that there are different types of MIBI washout in hyperplastic glands, otherwise some abnormal glands might be missed

  5. Original Article. Protection studies of new bis quaternary 2-(hydroxyimino-N-(pyridin-3yl acetamide derivatives (HNK-series oximes against acute poisoning by dichlorvos (DDVP in Swiss albino mice

    Directory of Open Access Journals (Sweden)

    Kumar Pravin

    2016-12-01

    Full Text Available The available antidotal therapy against acute poisoning by organophosphates involves the use of atropine alone or in combination with one of the oximes, e.g. 2-PAM, Obidoxime, TMB-4 or HI-6. Each of these oximes has some limitation, raising the question of the universal antidotal efficacy against poisoning by all OPs/nerve agents. In the present study, newly synthesized bis quaternary 2-(hydroxyimino-N-(pyridin-3yl acetamide derivatives (HNK-series oximes were evaluated for their antidotal efficacy against DDVP intoxicated Swiss mice, in terms of the Protection Index (PI and AChE reactivation in brain and serum. The inhibition concentration (IC50 was determined in brain and serum after optimizing the time point for maximum inhibition (60 min post DDVP exposure. AChE reactivation efficacy of the HNK series was evaluated at IC50 and compared with 2-PAM. HNK-102 showed a ~2 times better Protection Index (PI as compared to 2-PAM against DDVP toxicity. IC50 at 60 min DDVP post exposure was found to be approximately one fifth and one half of the LD50 dose for brain and serum AChE, respectively. Out of three HNK oximes, HNK-102 & 106 at 0.20 LD50 dose significantly reactivated DDVP intoxicated brain AChE (p<0.05 as compared to 2-PAM at double IC50 dose of DDVP. In light of double PI and higher AChE reactivation, HNK 102 was found to be a better oxime than 2-PAM in the treatment of acute poisoning by DDVP.

  6. Quantitative assessment of thallium myocardial washout rate: Importance of peak heart rate and lung thallium uptake in defining normal values

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Kozuka, Takahiro; Saito, Muneyasu; Sumiyoshi, Tetsuya; National Cardiovascular Center, Suita, Osaka

    1987-01-01

    Traditionally, the results of exercise thallium scintigraphy were interpreted by transient defect analysis using initial and delayed images. Recently, washout rate analysis has been used for the relative quantification of exercise thallium scintigraphy. A diffuse slow washout from all myocardial regions has been defined as the indicator of extensive coronary artery disease. However, slow washout has occasionally been observed in normal cases and in healthy myocardial segments which are not supplied by a stenosed artery in patients with single or double vessel disease. We evaluate the factors influencing washout rate in 100 normal patients and 63 patients with angina pectoris (33 cases of single vessel disease and 30 cases of double vessel disease). The washout rates were calculated using circumferential profile analysis. In normal patients, washout rate was closely related to peak heart rate (r=0.72) and inversely related to lung thallium uptake (r=-0.56). A diffuse slow washout was observed in seven (7%) of 100 normal patients, six (18%) of 33 cases of single vessel disease and eight (24%) of 30 cases of double vessel disease. The patients with diffuse slow washout showed significantly higher lung thallium uptake values and lower peak heart rates than those without diffuse slow washout (P<0.01). Thus, this false positive slow washout should be considered in the interpretation of quantitative exercise thallium scintigraphy. (orig.)

  7. Accuracy of preoperative diagnosis for primary hyperparathyroidism by CT, US and scintigraphy

    International Nuclear Information System (INIS)

    Imada, Masanobu; Nonaka, Satoshi; Hayashi, Tatsuya; Kunibe, Isamu; Harabuchi, Yasuaki

    2003-01-01

    We determined the usefulness of computed tomography (CT), ultrasonography (US) and Tc-Tl subtraction scintigraphy for preoperative diagnosis in 12 patients with primary hyperparathyroidism, all of which were solitary adenoma. Seven (63.6%) of 11 tumors were detected by CT, 7 (58.3%) of 12 tumors were detected by US, and 7 (63.6%) of 11 tumors were detected by Tc-Tl subtraction scintigraphy. Of 7 tumors with size>10 mm, 6 (85.7%) were detected by CT, 5 (71.4%) were detected by US, and 6 (85.7%) were detected by Tc-Tl subtraction scintigraphy, whereas only 1 (25%) with a diameter of 10 mm was detected by each of CT or Tc-Tl subtraction scintigraphy and 2 (40%) with diameters 10 mm were detected by US. Of 6 tumors situated behind the thyroid gland or intra thyroid gland, 5 (83.3%) were detected by CT and all 6 (100%) were detected by US, Tl-Tc subtraction scintigraphy, which was employed for 5 tumors, detected all 5 (100%). However, in the tumors situated beneath the thyroid gland only 2 (40%) of 5, 1 (16.7%) of 6 and 2 (33.3%) of 6 were detected by CT, US and Tc-Tl subtraction scintigraphy respectively. In 5 tumors without thyroid disease, 4 (80%) of 5 were detected by both CT and US, 3 (75%) of 4 were detected by Tc-Tl subtraction scintigraphy. However, in 7 tumors with thyroid diseases (papillary carcinoma, follicular carcinoma, follicular adenoma, chronic thyroiditis, and adenomatous goiter), 3 (50%) of 6 were detected by CT, 3 (42.9%) of 7 were detected by US and 4 (57.1%) of 7 were detected by Tc-Tl subtraction scintigraphy. Location of tumor was the factor most likely to make appropriate diagnosis difficult for primary hyperparathyroidism by any assessment method. (author)

  8. Gallium67 scintigraphy in fibrinous pericarditis associated with bacterial endocarditis

    International Nuclear Information System (INIS)

    Martin, P.; Verhas, M.; Devriendt, J.; Goffin, Y.

    1982-01-01

    An 80-year-old man presented with pyrexia, progressive cardiac failure and inflammation. A diagnosis of pericarditisd associated with bacterial endocarditis was suggested from Gallium 67 scintigraphy and confirmed at autpsy. This case of fibrinous pericarditis without effusion could not be diagnosed by echography or routine cardiopulmonary scintigraphy. (orig.)

  9. New agents for scintigraphy in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Bois, M.H.W. de; Pauwels, E.K.J.; Breedveld, F.C.

    1995-01-01

    Radiopharmaceuticals have been used as investigative tools for the detection and treatment of arthritis activity in rheumatoid arthritis (RA) since the 1950s. Against the background of the pathophysiology of RA, the current status of joint scintigraphy and possible future developments are reviewed. Both non-specific (radiolabelled leucocytes and technetium-99m labelled human immunoglobulin) and specific targeting radiopharmaceuticals (including radiolabelled antibodies) are considered. The use of radiopharmaceuticals in the detection of arthritis activity has the advantages of allowing direct imaging of joints by means of whole-body scintigraphy and of joints that are difficult to assess clinically or radiographically. Promising results have been obtained with radiolabelled anti-CD4 and anti-E-selectin antibodies and with somatostatin receptor imaging, but more data are available regarding 99m Tc-IgG scintigraphy, which differentiates between the various degrees of arthritis activity and thus facilitates the choice of antirheumatic drug. Newer promising approaches to the imaging of RA include the use of radiolabelled J001 and cytokines, though studies on these are limited at present. (orig.)

  10. Childhood acute pyelonephritis: comparison of power Doppler sonography and Tc-DMSA scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Stogianni, Aggeliki; Oikonomou, Ippoliti; Dimitriadis, Athanasios [Aristotle University of Thessaloniki, Department of Radiology, AHEPA Hospital, Thessaloniki (Greece); Nikolopoulos, Panagiotis [424 Army Hospital, Department of Radiology, Thessaloniki (Greece); Gatzola, Magdalini [Aristotle University of Thessaloniki, 2nd Paediatric Clinic, AHEPA Hospital, Thessaloniki (Greece); Balaris, Vassilios [Aristotle University of Thessaloniki, Department of Nuclear Medicine, AHEPA Hospital, Thessaloniki (Greece); Farmakiotis, Dimitrios [Infectious Diseases Hospital of Thessaloniki, Department of Medicine, Thessaloniki (Greece)

    2007-07-15

    Tc 99m DMSA scintigraphy is regarded as the gold standard for the detection and localization of acute pyelonephritis (APN) in children. Power Doppler sonography (PD US) is a radiation-free and cost-effective technique that could be useful in the diagnosis of APN in children. To compare the predictive value of PD US with DMSA scintigraphy in the diagnosis of APN in children. A total of 74 neonates and children with clinical findings consistent with possible upper urinary tract infection were evaluated with PD US and DMSA scintigraphy. Children with anatomic (grey-scale) abnormalities were excluded. A total of 147 kidneys were examined within the first 48 h after the onset of symptoms. Each kidney was divided into three zones (upper, middle, and lower third). APN was diagnosed by PD US in 46 kidneys. Sensitivity and specificity for detecting APN using DMSA scintigraphy as the reference standard were 73.8% and 85.7%, respectively. There was good agreement between PD US and DMSA scintigraphy in the localization of lesions. In clinically suspected APN, PD US has acceptable specificity and sensitivity, if performed within the first 48 h and could be helpful in neonates and children under 3 months of age in whom the use of scintigraphy is generally discouraged. (orig.)

  11. Twenty cases of ectopic thyroid gland detected by thyroid scintigraphy

    International Nuclear Information System (INIS)

    Hashimoto, Teisuke; Kubo, Atsushi; Hashimoto, Shozo

    1988-01-01

    20 cases of ectopic thyroid gland were detected out of 5,261 thyroid scintigraphy from 1973. Except for 1 case, all cases were female. Considering of thyroid function, 11 cases were euthyroid and rest of 9 cases were hypothyroid function. Clinical symptom of hypothyroid cases were mainly retarded linear growth and high value of serum TSH and in case of euthyroid cases were sublingual tumor and fullness or tightness in throat. Thyroid scintigraphy is very useful to diagnose the sublingual tumor whether it is ectopic thyroid gland or not. In case of congenital hypothyroidism children, ectopic thyroid gland causing hypothyroidism is definitely diagnosed by thyroid scintigraphy. (author)

  12. Theoretical study of the nucleophilic addition of oximes to the nitrile complexes trans-/cis-[ReCl4(NCCH3)2

    International Nuclear Information System (INIS)

    Klestova-Nadeeva, E. A.; Kuznetsov, M. L.; Dement'ev, A. I.

    2005-01-01

    The reaction of nucleophilic addition of oximes (HON=CRR 1 ) to organic nitriles coordinated in the rhenium complexes trans-/cis-[ReCl 4 (NCCH 3 ) 2 ] was theoretically studied by the Hartree-Fock and density functional theory (B3LYP) methods. The reaction mechanism involves (I) the initial change of the oxime conformation; (II) the formation of the orientation complex with the coordinated nitrile molecule, which transforms into a four-membered transition state; (III) the formation of the addition product in a less stable conformation; and (IV) the formation of the ultimate addition product. The calculations make it possible to interpret the activation of nitriles in terms of the activated complex theory as a result of stabilization of the transition state in going from the free to the coordinated nitrile [ru

  13. The value of myocardial scintigraphy in hypertrophic cardiomyopathy with angina pectoris

    International Nuclear Information System (INIS)

    Bergen, J.M.; Simons, M.

    1981-01-01

    Myocardial scintigraphy with thallium-201 is a new, non-invasive diagnostic method by means of which on special indications ischaemic heart diseases may be demonstrated. The case history is described of a man with hypertrophic cardiomyopathy and angina pectoris. The electrocardiogram at rest was affected by the cardiomyopathy to such a degree that the interpretation of the ST-T segment during effort was not reliable. Scintigraphy revealed transient ischaemia. A bypass operation was carried out and post-operatively, the improved myocardial perfusion could be confirmed by myocardial scintigraphy. (Auth.)

  14. Lung function studies in diagnostics and follow-up of pulmonary sarcoidosis

    International Nuclear Information System (INIS)

    Braadvik, I.

    1994-06-01

    In 66 patients the relationship between lung volumes and lung mechanics in pulmonary sarcoidosis was investigated. Lung volumes, static lung mechanics, lung resistance, dynamic lung mechanics and arterial blood gases at rest and during exercise were obtained. Fifteen functionally compromised patients received steroids during one year. They were re-investigated during the treatment and at a follow-up after an average of 7 years. In another 41 patients with newly diagnosed sarcoidosis, the kinetics of the lung clearance of 99m Tc-DTPA measured over 180 minutes was explored, and compared to kinetics in healthy smokers. The relationship between lung clearance and lung volumes, lung mechanics, arterial blood gases and disease activity assessed with serum angiotensin-converting enzyme and 67 Ga scintigraphy was studied. Reducing lung volumes and compliance, increased resistance and arterial oxygen tension were common. Vital capacity (VC), and changes of VC at follow-up, corresponded to the slope of the static elastic pressure/volume curve, and to the variation of it. Other static lung volumes reflected rather the position of the curve along the volume axis. Reduced VC also reflected obstruction. Forced expiratory volume in one second revealed to equal extent lung stiffness and obstruction. Lung mechanics showed abnormalities not always evident from spirometry.In 50% of the patients lung clearance of 99m Tc-DTPA disclosed an abnormally fast mono-exponential clearance or a bi-exponential clearance, which however differed from that in smokers. Lung clearance more readily detected abnormal function than did spirometry. Clearance did nor correlate with other investigations. 67 Ga lung activity was higher in patients with a pathologic lung clearance

  15. Clinical evaluation of exercise thallium-201 whole body scintigraphy in ischemic heart disease

    International Nuclear Information System (INIS)

    Kaneko, Kenzo; Watanabe, Yoshihiko; Kondo, Takeshi

    1985-01-01

    To evaluate whole body distribution and kinetics of Thallium-201 at exercise and redistribution, whole body scintigraphy (WB-S) was performed on 12 normal subjects (N), 19 patients with angina pectoris (AP) and 18 patients with old myocardial infarction (MI). WB-S was obtained using a gamma camera OMEGA 500 and analized by ADAC System IV. We estimated the following parameters from WB-S; 1) %Distribution (%D): the ratio of whole body counts to organ counts 2) washout rate (WR) in each organ. %D of the heart in N, AP and MI was similar at rest and exercise. At exercise, %D of the lung and the liver decreased and %D of thighs increased remarkably than at rest. At supine exercise, the lung indicated high %D and thinghs indicated low %D compared with at upright exercise. WR of the heart in AP and MI was significantly lower than in N (p<0.005, p<0.01) and further decreased proportionally to the number of stenotic coronary arteries and related to the ischemic ST depression of exercise ECG. WR of the heart was not correlation with pressure rate product and this finding suggested that WR of the heart was not prescribed by the tolerance of exercise but related to coronary flow at exercise a certain degree. WR of the lung in MI was significantly higher (p<0.025) and WR of thighs in AP and MI was significantly lower (p<0.025, p<0.05) compared with N. (author)

  16. Bone scintigraphy in chondroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Humphry, A.; Gilday, D.L.; Brown, R.G.

    1980-11-01

    Scintigraphy in 3 patients with chondroblastoma showed that the tumors were hyperemic and avidly accumulated the radionuclide. These changes were also present in adjacent normal bone, but to a lesser degree. This suggests that radionuclide uptake in chondroblastoma is a function of the blood supply to the tumor rather than primary matrix extraction.

  17. Scintigraphy and ultrasonography of various thyroid diseases

    International Nuclear Information System (INIS)

    Ban, Yoshio; Nagakura, Hozumi; Kawauchi, Akihiro; Fukunari, Nobuhiro; Itoh, Kunihiko; Higashi, Tomomitsu.

    1987-01-01

    We reported the usefulness of scintigraphy and ultrasonography of various thyroid diseases. The scintigraphy were useful information in the determination of functioning adenoma, location of ectopic thyroid glands and appearance of lang and bone metastasis of thyroid carcinoma. As ultrasonography were able to be observation of internal structure of thyroid gland, that maight be used to determined associated nodular lesions in diffuse goiter and differentiation between benign and malignant tumor in nodular goiter. In observation of calcifications of goiter, soft X rays apparatus were usefull tool. US, as initial diagnostic test before scintiscanning, provided useful information and minimized radiation exposure. (author)

  18. Guidelines for radioiodinated MIBG scintigraphy in children.

    Science.gov (United States)

    Olivier, Pierre; Colarinha, Paula; Fettich, Jure; Fischer, Sibylle; Frökier, Jörgen; Giammarile, Francesco; Gordon, Isky; Hahn, Klaus; Kabasakal, Levent; Mann, Mike; Mitjavila, Mercedes; Piepsz, Amy; Porn, Ute; Sixt, Rune; van Velzen, Jeannette

    2003-05-01

    These guidelines on the use of radioiodinated (99m)Tc-MIBG scintigraphy in children, which summarise the views of the Paediatric Committee of the European Association of Nuclear Medicine, provide a framework which may prove helpful to nuclear medicine teams in daily practice. They have been influenced by the conclusions of the "Consensus Guidelines for MIBG Scintigraphy" (Paris, November 6, 1997) of the European Neuroblastoma Group and by those of the Oncological Committee of the French Society of Nuclear Medicine. The guidelines should be taken in the context of "good practice" and any local/national rules which apply to nuclear medicine examinations.

  19. The role of DMSA renal scintigraphy in the first episode of urinary tract infection in childhood

    International Nuclear Information System (INIS)

    Supavekin, S.; Pravisithikul, N.; Kutanavanishapong, S.; Chiewvit, S.; Surapaitoolkorn, W.

    2013-01-01

    The role of dimercaptosuccinic acid (DMSA) renal scintigraphy in the first episode of urinary tract infection (UTI) has been the subject of debate for many years. The aim of this study was to evaluate the relationship of voiding cystourethrography (VCUG), renal ultrasonography and DMSA renal scintigraphy and to detect renal parenchymal changes by performing DMSA renal scintigraphy at 6 months after the first episode of UTI. A prospective study was conducted in 67 hospitalized children (46 boys, 21 girls). Mean age of the patients was 0.97±1.57 years (0.02-7.26 years). All children received VCUG, renal ultrasonography and DMSA renal scintigraphy. DMSA renal scintigraphy was performed at 1 and 6 months after UTI. Of 67 children, 17 (25.4%), 23 (34.3%) and 20 (29.9%) had vesicoureteral reflux (VUR), abnormal renal ultrasonography and abnormal DMSA renal scintigraphy, respectively. Unilateral hydronephrosis had a significant correlation with VUR at p value 0.024. In renal units, abnormal renal ultrasonography and hydronephrosis had significant correlations with VUR at p values 0.039 and 0.021, respectively. In patients and renal units, hydronephrosis had no significant correlation with abnormal DMSA renal scintigraphy at 1 month after UTI. However, abnormal renal ultrasonography and VUR had significant correlations with abnormal DMSA renal scintigraphy at p values 0.022 and <0.001 in patients and at p values 0.024 and <0.001 in renal units, respectively. Both in patients and renal units, VUR (Grade I-III) had no significant correlation with abnormal DMSA renal scintigraphy. However, severe VUR (Grade IV-V) had significant correlations with abnormal DMSA renal scintigraphy at p values <0.001 and <0.001, respectively. Seventeen patients underwent DMSA renal scintigraphy at 6 months after UTI. In addition, 15 (88.2%) developed persistent renal scarring. Abnormal renal ultrasonography and severe VUR identify renal parenchymal changes. DMSA renal scintigraphy in the first

  20. Gamma-scintigraphy

    International Nuclear Information System (INIS)

    Desgrez, H.A.

    1960-06-01

    Gamma-scintigraphy is a medical technique making it possible to fix the image of certain organs after the concentration in these of emitting radioactive products. It is already widely used in the case of the thyroid gland with iodine-132 by applying the isotope iodine 131. The study of the liver and gall bladder is carried out using colloidal gold 198 and Bengal pink marked with iodine 131. Serum albumin marked with iodine 131 makes it possible to study rachidian blockages. Other applications can already be foreseen in this direction. (author) [fr

  1. Comparison of whole body MR diffusion weighted imaging and skeletal scintigraphy in detecting bone metastasis

    International Nuclear Information System (INIS)

    Xu Xian; Ma Lin; Zhang Jinshan; Cai Youquan; Cheng Liuquan; Guo Xinggao; Xu Baixuan

    2008-01-01

    Objective: To evaluate the application of whole body MR diffusion weighted imaging (DWI) in the detection of bone metastasis using skeletal scintigraphy as the reference. Methods: Forty-two healthy volunteers and 38 patients with malignant tumors were enrolled in our study. All the patients received MR examination and skeletal scintigraphy within one week. MR examination was performed on GE signa 3.0T MR scanner using a build-in body coil. The skeletal system was divided into eight regions and the images of the whole body MR DWI and skeletal scintigraphy were reviewed to compare the two modalities patient by patient and region by region. The images were reviewed separately by two radiologists and two nuclear medicine physicians, who were blinded to the results of another imaging modality. Results: A total of 169 metastatic lesions in 69 regions of 30 patients were detected by whole body MR DWI while 156 lesions in 68 regions of 29 patients were identified by skeletal scintigraphy. There were two cases negative in scintigraphy but positive in whole body MR DWI and one case positive in scintigraphy only. There were eight lesions negative in scintigraphy but positive in whole body MR DWI, mainly located in the spine, pelvis and femur. Seven lesions were only detected by scintigraphy, mainly located in the skull, sternum, clavicle and scapula. Conclusion: The whole body MR DWI reveals excellent consistency with skeletal scintigraphy regarding bone metastasis, and the two modalities are complementary for each other. (authors)

  2. Whole-body /sup 67/Ga scintigraphy in dermatomyositis

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, Yoshio; Okazaki, Yoshio; Murakami, Kiminori; Inoue, Nobuhiro; Noriyasu, Toshiaki; Takeda, Yoshihiro; Morimoto, Setsuo; Aono, Kaname

    1987-10-01

    The presence or absence of abnormal accumulation of gallium-67 in soft tissues was studied in 11 patients undergoing /sup 67/Ga scintigraphy out of 25 patients with dermatomyositis and polymyositis (DM-PM) who had visited our hospital during the period between July 1981 and March 1987 and met the diagnostic criteria of muscle biopsy, etc. A definite image of abnormal accumulation was obtained by /sup 67/Ga scintigraphy in 3 of the patients. Although the positive site tended to be in agreement with the site of muscular symptoms in the DM-PM active stage, the accumulation was not necessarily correlated with the variations in creatine phosphokinase. From these results, it seems necessary to keep in mind the possibility that gallium-67 may also accumulate abnormally in the soft tissue lesion owing to the pathogenic process specific to DM-PM when /sup 67/Ga scintigraphy is undertaken for the purpose of screening, etc., for complication by a malignant tumor in DM-PM patients

  3. Bone scintigraphy in a case of Ollier's disease

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Nobuaki; Ito, Yasuhiko; Morita, Rikushi [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1983-11-01

    Bone scintigraphy with sup(99m)Tc-MDP was performed on a case with a Ollier's disease. Compared with Bone X-ray examinations, increased activity is noted in the ribs, hands (esp. left), left humerus, left tibia and left foot. Tumor scintigraphy with /sup 67/Ga-citrate shows slightly increased accumulation in comparison with sup(99m)Tc-MDP findings. However, apparent change was not noted compared with the previous scans. So, malignant change was negative. Malignant bone tumors usually show high activity, but some benign tumors also show high uptake. So, a differential diagnosis of bone disease using sup(99m)Tc-phosphorous compounds is occasionally difficult. In case of Ollier's disease, a follow-up bone scintigraphy is useful for evaluation of tumor growth, because malignant changes were accompanied by intensive uptake of sup(99m)Tc-MDP. Also, /sup 67/Ga-study is necessary for the differentiation of bone disease.

  4. Lung perfusion characteristics in pulmonary arterial hypertension (PAH) and peripheral forms of chronic thromboembolic pulmonary hypertension (pCTEPH): Dual-energy CT experience in 31 patients

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, Jessica; Khung, Suonita; Remy, Jacques; Remy-Jardin, Martine [Hospital Calmette (EA 2694), Department of Thoracic Imaging, Lille (France); Duhamel, Alain [University Lille, CHU Lille, Department of Biostatistics, Lille (France); Hossein-Foucher, Claude; Bellevre, Dimitri [University Lille, CHU Lille, Department of Nuclear Medicine, Hospital Salengro, Lille (France); Lamblin, Nicolas [University Lille, CHU Lille, Department of Cardiology, Cardiology Hospital, Lille (France)

    2017-04-15

    To compare lung perfusion in PAH and pCTEPH on dual-energy CT (DECT) examinations. Thirty-one patients with PAH (group 1; n = 19) and pCTEPH (group 2; n = 12) underwent a dual-energy chest CTA with reconstruction of diagnostic and perfusion images. Perfusion alterations were analysed at a segmental level. V/Q scintigraphy was available in 22 patients (group 1: 13/19; group 2: 9/12). CT perfusion was abnormal in 52.6 % of group 1 patients and in 100 % of group 2 patients (p = 0.0051). The patterns of perfusion alteration significantly differed between the two groups (p < 0.0001): (1) in group 1, 96.6 % of segments with abnormal perfusion showed patchy defects; (2) in group 2, the most frequent abnormalities consisted of patchy (58.5 %) and PE-type (37.5 %) defects. Paired comparison of CT perfusion and scintigraphy showed concordant findings in 76.9 % of group 1 (10/13) and 100 % of group 2 (9/9) patients, with a predominant or an exclusive patchy pattern in group 1 and a mixed pattern of abnormalities in group 2. Lung perfusion alterations at DECT are less frequent and more homogeneous in PAH than in pCTEPH, with a high level of concordant findings with V/Q scintigraphy. (orig.)

  5. Validity of 67Ga scintigraphy in patients with oral cancer

    International Nuclear Information System (INIS)

    Kanemura, Hironari; Kondoh, Toshirou; Hamada, Yoshiki; Nakajima, Toshifumi; Sekiya, Hideki; Ito, Ko; Sato, Junichi; Seto, Kanichi

    2003-01-01

    In this study, we investigated the diagnostic usefulness of 67 Ga scintigraphy in patients with oral cancer. Fifty-five patients with previously untreated oral cancer were administered in this study. The diagnostic accuracy of 67 Ga scintigraphy for primary cancer, cervical lymph node metastasis, systemic metastasis or double cancer were studied. The relations of the size of lesions to the diagnostic accuracy, and the degree of 67 Ga-citrate accumulation were analyzed. In addition, we discussed what makes it difficult to diagnose the lesions by using 67 Ga scintigrams. As a result, the sensitivity was 44.2% in primary cancer, 28.6% in cervical lymph node metastasis, and 25.0% in systemic metastasis or double cancer. It was suggested that 67 Ga scintigraphy is disadvantageous for the detection of small lesions. In this study, the relation between the size of lesions and the degree of 67 Ga-citrate accumulation was not clarified. The diagnostic problems of 67 Ga scintigraphy were found to be its low reliability in imaging of the lesion's localization, normal biodistribution and non-specific accumulation of 67 Ga-citrate. (author)

  6. Prediction of postoperative pulmonary function using 99mTc-MAA perfusion lung SPECT

    International Nuclear Information System (INIS)

    Hosokawa, Nobuyuki; Tanabe, Masatada; Satoh, Katashi; Takashima, Hitoshi; Ohkawa, Motoomi; Maeda, Masazumi; Tamai, Toyosato; Kojima, Kanji.

    1995-01-01

    In order to predict postoperative pulmonary function, 99m Tc-MAA perfusion lung SPECT and spirometry were performed preoperatively in 52 patients with resectable primary lung cancer; 44 underwent lobectomy, eight pneumonectomy. Local pulmonary function (called local effective volume) was evaluated according to the degree of radionuclide distribution of each voxel in the SPECT images. The total effective volume was defined as the sum of the local effective volume, and the residual effective volume was the total effective volume excluding loss after operation. Predicted pulmonary function (VC and FEV 1.0) was calculated by the following formula: Predicted value=preoperative value x percent of the residual effective volume. Postoperative pulmonary function was predicted in the same patients by means of 99m Tc-MAA perfusion lung planar scintigraphy and X-ray CT. The patients were reinvestigated with spirometry at one and four months after surgery, and the values were compared with the predicted values. The correlations between the predicted values using SPECT and measured postoperative pulmonary function were highly significant (VC: r=0.867, FEV1.0: r=0.864 one month after operation; VC: r=0.860, FEV1.0: r=0.907 4 months after operation). The predicted values calculated using SPECT were accurate compared with the predicted values calculated using planar scintigraphy or X-ray CT. The patients with predicted FEV1.0 of less than 0.8 liter required home oxygen therapy. This method is valuable for the prediction of postoperative pulmonary function before the surgical procedure. (author)

  7. Guidelines for MIBG-scintigraphy in children

    International Nuclear Information System (INIS)

    Olivier, P.; Colarinha, P.; Fettich, J.; Fischer, S.; Hahn, K.; Porn, U.; Froekier, J.; Giammarile, F.; Gordon, I.; Kabasakal, L.; Mann, M.; Mitjavila, M.; Piepsz, A.; Sixt, R.; Velzen, J. van

    2002-01-01

    These ''Empfehlungen'' are the german translation of the Guidelines on MIBG-Scintigraphy in Children, which were published by the Paediatric Committee of the European Association of Nuclear Medicine. (orig.) [de

  8. Comparison of CT and scintigraphy in diseases of the liver

    International Nuclear Information System (INIS)

    Wenig, H.G.; Wegener, O.H.; Souchon, R.; Ziegler, U.; Koppenhagen, K.

    1979-01-01

    Sixty-five patients with various diseases of the liver were examined by CT and scintigraphy. We found the following preliminary conclusions: diffusely infiltrative and hepatocellular diseases of the liver, espacially cirrhosis, are recognized on CT by shape and contour rather than by density values. In these cases, scintigraphy provides important information about the function of the parenchyma. In space-occupying processes, a close correlation exists between CT and scintigraphy. In the investigation of liver metastases in advanced stages, CT and radionuclide studies proved to be nearly identical in accuracy. The advantages of CT consist in the possibility of showing more morphologic detail of adjacent organs and in possessing better spatial resolution. (orig.) 891 MG/orig. 892 MB [de

  9. Update on Nonsurgical Lung Volume Reduction Procedures

    Directory of Open Access Journals (Sweden)

    J. Alberto Neder

    2016-01-01

    Full Text Available There has been a surge of interest in endoscopic lung volume reduction (ELVR strategies for advanced COPD. Valve implants, coil implants, biological LVR (BioLVR, bronchial thermal vapour ablation, and airway stents are used to induce lung deflation with the ultimate goal of improving respiratory mechanics and chronic dyspnea. Patients presenting with severe air trapping (e.g., inspiratory capacity/total lung capacity (TLC 225% predicted and thoracic hyperinflation (TLC > 150% predicted have the greatest potential to derive benefit from ELVR procedures. Pre-LVRS or ELVR assessment should ideally include cardiological evaluation, high resolution CT scan, ventilation and perfusion scintigraphy, full pulmonary function tests, and cardiopulmonary exercise testing. ELVR procedures are currently available in selected Canadian research centers as part of ethically approved clinical trials. If a decision is made to offer an ELVR procedure, one-way valves are the first option in the presence of complete lobar exclusion and no significant collateral ventilation. When the fissure is not complete, when collateral ventilation is evident in heterogeneous emphysema or when emphysema is homogeneous, coil implants or BioLVR (in that order are the next logical alternatives.

  10. Methodological problems of sacroiliac joint scintigraphy

    International Nuclear Information System (INIS)

    Schoerner, W.; Haubold, U.

    1981-01-01

    Bone scintigraphy of the sacroiliac joints and the lumbar spine was performed in 35 patients with ankylosing spondylitis and 30 control subjects. The scans were evaluated by qualitative and quantitative assessment. The sacroiliac/sacrum ratio (index ISG/sacrum), the sacroiliac/lumbar spine ratio (index ISG/LWS), and the left sacroiliac joint/right sacroiliac joint ratio (index li. ISG/re. ISG) were calculated. The visual interpretation of colour scans proved to be unreliable. The index ISG/sacrum was more sensitive than the index ISG/LWS. The index li. ISG/re. ISG was helpful as an additional criterion. When digital sacroiliac joint scintigraphy is well standardized it can be considered as a useful technique in early diagnosis of ankylosing spondylitis. (orig.) [de

  11. Parathyroid scintigraphy in chronic renal failure

    International Nuclear Information System (INIS)

    Baulieu, J.L.; Houlier, S.; Baulieu, F.; Rousseau, C.

    1995-01-01

    The performances of the scintigraphic localization of parathyroid adenoma have improved with the use of technetium-99m radiolabeled tracers and the development of thyroid subtraction methods. By using methoxy--isobutyl-isonitrile (MIB) alone in two phases, sensitivity and specificity are respectively O.85 and 0.92. The interest of scintigraphy compared with ultrasonography is specially marked in the situations encountered in patients with renal failure: hyperplasia, multiple or ectopic adenoma, association with thyroid nodules. However, the localisation of adenoma remains more difficult in renal failure than in primary hyperthyroidism. Scintigraphy seems to be essential for localizing adenoma and eventually hyperplasia, before surgery in patients in bad conditions or before a second operation. (authors). 26 refs., 3 figs., 2 tabs

  12. Bone scintigraphy in renal osteopathy

    International Nuclear Information System (INIS)

    Hermann, H.J.; Gahl, G.; Freie Univ. Berlin

    1976-01-01

    25 patients with chronic renal disease are investigated. In 16 cases with conservative treatment the bone scintigram showed pathological uptake according to the creatinine level, mainly in the joints of iliosacrum, hip, knee and ankles. In three patients increased uptake in the skull was found. The bone uptake found by scintigraphy was highly pronounced in the patients treated by dialysis. The most frequently involved regions were the joints of iliocacrum and hip, facial cranium, skull, pelvis and metatarsus. The count-rate ratio of cranium to chest was significantly increased in 6 patients. The investigations 6 months later showed in 4 cases a further increase compared with the first values. Count-rates of the skull were found to be comparable to the highly increased uptake in Paget's disease. Bone scintigraphy is a suitable method to estimate semiquantitatively the bone turnover in renal disease. (orig.) [de

  13. Bone scintigraphy in renal osteodystrophy

    International Nuclear Information System (INIS)

    de Graaf, P.; Schicht, I.M.; Pauwels, E.K.J.; te Velde, J.; de Graeff, J.

    1978-01-01

    Bone scintigraphy with Tc-99m HEDP was performed in 30 patients on maintenance hemodialysis, and the results of quantitative analysis were compared wth those of a normal group. To permit this comparison, elevated background activity due to the absence of renal radiotracer excretion was reduced by hemodialysis to levels found in the normals. Histologic proof of renal osteodystrophy had been obtained in all patients. the incidence of radiographic abnormalities was 46%, whereas abnormal scans were found in 25 patients (83%); skeletal lesions were also more pronounced and detected earlier. However, even when the scans appeared normal, the quantitative analysis showed increased skeletal activity in all patients. The total skeletal activity proved to be a good index of the severity of renal osteodystrophy and appeared dependent on both osteomalacia and hyperparathyroidism. These findings show that bone scintigraphy is a sensitive method to detect skeletal involvement in renal osteodystrophy

  14. Myocardium scintigraphy and coronaries scanner: results and respective contribution of these two examinations; Scintigraphie myocardique et scanner coronaire: resultats et apport respectif des deux examens

    Energy Technology Data Exchange (ETDEWEB)

    Songy, B.; Balestrini, V.; Sablayrolles, J.L.; Vigoni, F.; Lussato, D. [Centre cardiologique du Nord (CCN), Saint-Denis, (France); Faccio, F. [fondation San Geronimo, Santa Fe, (Argentina)

    2009-05-15

    The objective were to evaluate the results and the respective contribution of the myocardium scintigraphy and the coro-scanner. It exists an excellent correlation between a normal scanner and a normal scintigraphy (97%). 30% of patients having non tight stenosis at scanner and 60% of these ones having tight stenosis have a scintigraphy ischemia; An abnormal scanner, whatever be the the degree of stenosis must be completed by a test of myocardium ischemia. The actual limitations of the coro-scanner (64 gills) are in relation with its spatial resolution (quantification) and temporal resolution (right coronary). The choice of the diagnosis examination to realize in first intention must depend on the age and prevalence of the coronary disease. (N.C.)

  15. Clinical need for both scintigraphy with technetium-99m GSA and per-rectal portal scintigraphy in some patients with chronic liver disease

    Energy Technology Data Exchange (ETDEWEB)

    Shiomi, Susumu; Iwata, Yoshinori; Sasaki, Nobumitsu [Osaka City Univ. (Japan). Medical School] (and others)

    1999-08-01

    Scintigraphy with {sup 99m}Tc-diethylenetriaminepentaacetate with galactosyl human serum albumin ({sup 99m}Tc-GSA) and per-rectal portal scintigraphy are useful for evaluating hepatic functional reserve and portal circulation, respectively. We did the procedures simultaneously in some patients to examine the relationship between hepatic functional reserve and portal circulation in chronic liver disease. Scintigraphy with {sup 99m}Tc-GSA was done in 10 healthy subjects, 45 patients with chronic hepatitis, and 165 patients with cirrhosis. Fifty-seven patients (13 with hepatitis and 44 with cirrhosis) also underwent per-rectal portal scintigraphy with {sup 99m}Tc-pertechnetate within two weeks. A receptor index was calculated by dividing the radioactivity of the liver region of interest (ROI) by that of the liver-plus-heart ROI at 15 min after the injection of {sup 99m}Tc-GSA. The index of blood clearance was calculated by dividing the radioactivity of the heart ROI at 15 min by that of the heart ROI at 3 min. A solution containing {sup 99m}Tc-pertechnetate was instilled into the rectum, and serial scintigrams were taken while radioactivity curves for the liver and heart were recorded sequentially. A per-rectal portal shunt index was determined by calculating the ratio of counts for the liver to counts for the heart integrated for 24 seconds immediately after the appearance of the liver time-activity curve. The median receptor index was lower for more severe liver disorders, increasing in the order of chronic hepatitis, compensated cirrhosis and decompensated cirrhosis, and the median index of blood clearance was higher. The median receptor index was significantly lower when a complication (varices, ascites, or encephalopathy) was present, and the median index of blood clearance was higher. The shunt index was correlated significantly with the two other indices, but these values for some one-third of the patients disagreed in either indices. Scintigraphy with {sup 99m

  16. Performances of scintigraphy in the primitive hyperparathyroidism and the associated thyroid pathologies

    International Nuclear Information System (INIS)

    Monteil, J.; Mathonnet, M.; Chianea, T.; Cubertafond, P.; Piquet, L.; Rince, C.; Bournaud, E.; Verbeke, S.; Perdrisot, R.; Vandroux, J.C.

    1997-01-01

    The data from scintigraphic and echographic exploration were compared to the surgery results in 32 patients (29 F and 3 M) presenting a primitive hyperparathyroidism, biologically proved, associated to a thyroid pathology. The scintigraphies were achieved with a collimator placed anteriorly and oblique-anteriorly, 4 h after injection by iodine 123 (7 MBq) and 30 min and 2 h after injection of 99m Tc-MIBI (555 MBq). The cervical echography and scintigraphy are independently interpreted. The results are given in a table containing the sensitivity, specificity, V.P.P. and V.P.N. for scintigraphy and echography, respectively. The association of a primary hyperparathyroidism and of a thyroid pathology (with a prevalence of 70% in our region) appears to affect less the performances of scintigraphy imaging than those of morphologic imaging

  17. Differential pulse polarographic determination of molybdenum (VI) in phosphoric medium by benzoin alpha oxime

    International Nuclear Information System (INIS)

    Chergouche, S.

    1992-02-01

    The extraction of Molybdenum (VI) using both 4-Methylpentane-2-one (hexone) and chloroform dissolved Benzoin-alpha-oxime has been investigated in order to develop a simple and sensitive polarographic method allowing the analysis of Molybdenum (VI) contained in industrial phosphoric acid produced in ANNABA (Eastern Algeria). The investigation takes into account various parameters such as: The stirring time, solvent rate, the number of stages ... as well as the organic phase conditioning during the polarographic analysis

  18. The localization of urinary tract infection with sup(99m)Tc glucoheptonate scintigraphy

    International Nuclear Information System (INIS)

    Traisman, E.S.; Conway, J.J.; Traisman, H.S.; Yogev, R.; Firlit, C.; Shkolnik, A.; Weiss, S.; Northwestern Univ., Chicago, IL; Children's Memorial Hospital, Chicago, IL

    1986-01-01

    A retrospective study was performed of 39 children at the Children's Memorial Hospital, Chicago, Illinois, who underwent technetium-99m glucoheptonate (sup(99m)TcGH) scintigraphy for evaluation of possible urinary tract infection. Clinical and laboratory criteria classified the children as having pyelonephritis, cystitis, or no urinary tract infection. Of 28 children classified as having pyelonephritis, 24 (86%) children had abnormalities on sup(99m)TcGH scintigraphy. Only 8 of 19 (42%) renal ultrasound scans and 4 of 17 (24%) intravenous pyelography studies performed in these children demonstrated findings consistent with parenchymal disease. Only 9 of 19 (47%) cystograms demonstrated vesicoureteral reflux. Three children who underwent gallium-67 citrate scintigraphy had localization at the sites of focal defects with sup(99m)TcGH scintigraphy. sup(99m)TcGH scintigraphy is a sensitive and specific indicator of renal parenchymal involvement that helps localize urinary tract infection to the kidney. (orig.)

  19. Gastroesophageal reflux: the acid test, scintigraphy or the pH probe

    International Nuclear Information System (INIS)

    Seibert, J.J.; Byrne, W.J.; Euler, A.R.; Latture, T.; Leach, M.; Campbell, M.

    1983-01-01

    The best established technique for diagnosing gastroesophageal reflux in children is the 24 hr esophageal pH probe test. No simultaneous comparison of this technique with radionuclide scans has been reported. Therefore, simultaneous 1 hr pH monitoring and gastroesophageal scintigraphy were performed in 49 infants and children with suspected gastroesophageal reflux. Forty-seven of these patients also were later monitored by the 24 hr pH probe test. Upper gastrointestinal series were performed on all patients. All patients with a positive 1 hr pH monitoring also had positive simultaneous scintigraphy. All patients with positive scintigraphy and pH probe monitoring also had a positive upper gastrointestinal series for reflux. The sensitivity of gastroesophageal scintigraphy, when compared to the 24 hr probe as a standard, was 79%; its specificity was 93%. The sensitivity of the upper gastrointestinal series was 86%, when compared to the 24 hr pH probe test. However, its specificity was only 21%

  20. Quantitative whole body scintigraphy - a simplified approach

    International Nuclear Information System (INIS)

    Marienhagen, J.; Maenner, P.; Bock, E.; Schoenberger, J.; Eilles, C.

    1996-01-01

    In this paper we present investigations on a simplified method of quantitative whole body scintigraphy by using a dual head LFOV-gamma camera and a calibration algorithm without the need of additional attenuation or scatter correction. Validation of this approach to the anthropomorphic phantom as well as in patient studies showed a high accuracy concerning quantification of whole body activity (102.8% and 97.72%, resp.), by contrast organ activities were recovered with an error range up to 12%. The described method can be easily performed using commercially available software packages and is recommendable especially for quantitative whole body scintigraphy in a clinical setting. (orig.) [de

  1. The thallium-201 myocardial scintigraphy, its possibilities and limitations

    International Nuclear Information System (INIS)

    Adam, W.; Meindl, S.; Schmitz, A.; Utech, C.; Boettcher, D.

    1983-01-01

    The Thallium-201 Myocardial Scintigraphy, its Possibilities and limitations: The Thallium-201 myocardial scintigraphy is a simple non-invasive procedure to detect hypo- and non-perfused myocardial regions. In the he last years it was demonstrated to be a helpful method in the diagnostic strategy for the cardiologist. It can not replace the coronary angiogram, but in many cases it appears to be useful in selecting patients for coronary angiography. (orig.) [de

  2. Functional bone marrow scintigraphy in psoriatics

    International Nuclear Information System (INIS)

    Munz, D.; Altmeyer, P.; Chilf, G.; Schlesinger, G.; Holzmann, H.; Hoer, G.

    1982-01-01

    24 psoriatics as well as 24 normal healthy adults were studied by functional bone marrow scintigraphy using Tc-99m-labeled human serum albumin millimicrospheres (Tc-99m-HSA-MM). Functional bone marrow scintigraphy is an in vivo test system for the assessment of various functional properties of fixed macrophages. 58% of psoriatics who had no systemic drug treatment demonstrated peripheral extension of the bone marrow space indicating hyperplasia of bone marrow macrophages. This phenomenon could be observed only in one normal subject who was a high-performance sportsman. 83% (n=6) of psoriatics with cirrhosis of liver demonstrated bone marrow extension. The 'capacity' of bone marrow macrophages to engulf Tc-99m-HSA-MM ('uptake ratio') was diminished in 42% of non-treated as well as 66% of psoriatics treated with aromatic retinoid. The phagocytic and proteolytic turnover of Tc-99m-HSA-MM in bone marrow, spleen, and liver was found to be accelerated in 66% of non-treated psoriatics, normal, accelerated or delayed in psoriatics treated with aromatic retinoid as well as considerably delayed in all of the psoriatics with cirrhosis of liver. Functional bone marrow scintigraphy proved to be an appropriate in vivo test system to reveal abnormalities of fixed macrophages in psoriatics. Furthermore, theratpeutic effects as well as influences of pre-existing disorders on different macrophage populations can be assessed. (Author)

  3. Value of 67Ga scintigraphy in primary diagnosis and follow-up of opportunistic pneumonias in patients with AIDS

    International Nuclear Information System (INIS)

    Tatsch, K.; Knesewitsch, P.; Kirsch, C.M.; Kueffer, G.; Doerner, G.; Moser, E.; Matuschke, A.; Bogner, J.; Goebel, F.D.

    1988-01-01

    Opportunistic pneumonias are a life-threatening complication in patients with AIDS. Early diagnosis and therapy is necessary to improve prognosis. This study was designed to assess the value of 67 Ga scintigraphy in the primary detection and follow-up of these special pneumonias. 67 Ga scintigraphy was performed in 40 patients: 10 normal controls and 30 HIV-positive patients with AIDS or AIDS-related complex (ARC). 67 Ga scan results were compared with current chest radiographs and the results of pathogen detection. The evaluation of positive scans was based on a quantification of the pulmonary uptake, expressed as a pulmonary/soft-tissue uptake ratio. Only 8/30 patients had a normal scan, 22/30 showed diffuse (13/22) or focal (9/22) increases of pulmonary uptake. In 7/8 patients with normal scans the chest radiograph was negative as well. The one patient with negative scan but positive chest radiograph had pulmonary Kaposi's sarcoma. In 11/22 patients the 67 Ga scan and chest radiograph were positive simultaneously. In the other 11/22 patients with positive scans chest radiographs were initially negative but showed pathology in 5 cases within 1-2 weeks. The reason for positive scans in most cases was an opportunistic lung infection; other forms of pneumonia were only observed in two cases. The defined uptake ratio demonstrated to be a highly sensitive parameter for monitoring pneumonia and the effects of therapy in follow-up studies. In conclusion, quantitative 67 Ga scintigraphy proved to be a reliable and highly sensitive method for primary detection and follow-up of opportunistic pneumonias in patients with AIDS. (orig.) [de

  4. Assessment of warfarin therapy under full dose using indium-111 platelet scintigraphy in patients with intracardiac thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Makoto; Onishi, Kenji; Fukunami, Masatake and others

    1988-12-01

    Twenty patients in whom intracardiac thrombi were detected by indium-111 platelet scintigraphy (the first platelet scintigraphy) were prospectively studied to examine the effect of warfarin therapy under full dose on the intracardiac thrombogenecity. Eleven patients (group I) who received 2-6 mg/day of warfarin and 9 patients (group II) who did not received warfarin had the second platelet scintigraphies 14-71 days after the first platelet scintigraphies. In group I, 10 platelet scintigraphies became negative and one remained positive for intracardiac thrombi after administration of warfarin, while in group II 8 platelet scintigraphies remained positive and only one changed to negative. The incidence of negative image at the second platelet scintigraphy was significantly lower in group II than that in group I. In group I, the degree of accumulation of platelets onto the surface of the thrombus (%IE), showed significant reduction (0.69+-0.48 to 0.11+-0.21) after warfarin therapy, while in group II %IE at the second scintigraphy (1.07+-1.03) were not significantly different from those at the first scintigraphy (1.13+-0.79). These results indicated that warfarin therapy under full dose inhibited the deposition of platelets on the intracardiac thrombi and thrombogenecity in the patients with intracardiac thrombi which were detected by indium-111 platelet scintigraphy.

  5. Assessment of warfarin therapy under full dose using indium-111 platelet scintigraphy in patients with intracardiac thrombi

    International Nuclear Information System (INIS)

    Yamada, Makoto; Onishi, Kenji; Fukunami, Masatake

    1988-01-01

    Twenty patients in whom intracardiac thrombi were detected by indium-111 platelet scintigraphy (the first platelet scintigraphy) were prospectively studied to examine the effect of warfarin therapy under full dose on the intracardiac thrombogenecity. Eleven patients (group I) who received 2-6 mg/day of warfarin and 9 patients (group II) who did not received warfarin had the second platelet scintigraphies 14-71 days after the first platelet scintigraphies. In group I, 10 platelet scintigraphies became negative and one remained positive for intracardiac thrombi after administration of warfarin, while in group II 8 platelet scintigraphies remained positive and only one changed to negative. The incidence of negative image at the second platelet scintigraphy was significantly lower in group II than that in group I. In group I, the degree of accumulation of platelets onto the surface of the thrombus (%IE), showed significant reduction (0.69±0.48 to 0.11±0.21) after warfarin therapy, while in group II %IE at the second scintigraphy (1.07±1.03) were not significantly different from those at the first scintigraphy (1.13±0.79). These results indicated that warfarin therapy under full dose inhibited the deposition of platelets on the intracardiac thrombi and thrombogenecity in the patients with intracardiac thrombi which were detected by indium-111 platelet scintigraphy. (author)

  6. Usefulness of 99mTc MIBI scintigraphy in hyperparathyroidism. A retrospective analysis of the surgical patients

    International Nuclear Information System (INIS)

    Nakamura, Toshiyuki; Kobayashi, Shinya; Fujimori, Minoru

    1998-01-01

    In patients who receive surgery for primary or secondary hyperparathyroidism, preoperative diagnosis of the location of the parathyroid glands is important. Ninety-nine-m Technetium methoxyisobutylisonitrile (MIBI) accumulates in the pathological parathyroid. We used MIBI scintigraphy to detect diseased parathyroid glands in 20 patients with hyperparathyroidism, and successfully located the glands in seventeen. The accuracy of MIBI scintigraphy (100%) is significantly (p<0.05) better than that of Thallium-Technetium subtraction scintigraphy (56%). In a patient with hyperparathyroidism due to an ectopic parathyroid gland, MIBI scintigraphy showed accumulation in a mediastinal gland. MIBI scintigraphy is thus useful for gland location in hyperparathyroidism. (author)

  7. Reproducibility of esophageal scintigraphy using semi-solid yoghurt

    Energy Technology Data Exchange (ETDEWEB)

    Imai, Yukinori; Kinoshita, Manabu; Asakura, Yasushi; Kakinuma, Tohru; Shimoji, Katsunori; Fujiwara, Kenji; Suzuki, Kenji; Miyamae, Tatsuya [Saitama Medical School, Moroyama (Japan)

    1999-10-01

    Esophageal scintigraphy is a non-invasive method which evaluate esophageal function quantitatively. We applied new technique using semi-solid yoghurt, which can evaluate esophageal function in a sitting position. To evaluate the reproducibility of this method, scintigraphy were performed in 16 healthy volunteers. From the result of four swallows except the first one, the mean coefficients of variation in esophageal transit time and esophageal emptying time were 12.8% and 13.4% respectively (interday variation). As regards the interday variation, this method had also good reproducibility from the result on the 2 separate days. (author)

  8. Bone scintigraphy for horses; Die Skelettszintigrafie beim Pferd

    Energy Technology Data Exchange (ETDEWEB)

    Jahn, Werner [Pferdeklinik Bargteheide (Germany)

    2010-03-15

    Scintigraphy (bone scan) is being used approximately since 1980 in the horse under general anaesthesia. With the construction of custom-made overhead gantries for gamma-cameras scintigraphy found widespread entry in big equine referral hospitals for bone-scanning of the standing horse. Indications for the use of a bone scan in the horse are inflammatory alterations in the locomotor apparatus. It is primarily used for diagnosis of lameness of unknown origin, suspect of stress fracture or hairline fracture and for horses with bad riding comfort with suspected painful lesions in the spine. (orig.)

  9. Dynamic gastroesophageal scintigraphy with 99mTc pyrophosphate

    International Nuclear Information System (INIS)

    Minchev, D.; Kovacheva, Yu.; Mlychkov, H.; Koev, A.

    1989-01-01

    Thirty two infants were examined by use of dynamic gastroesophageal scintigraphy and contrast X-ray for demonstrating gastroesophageal reflux. The radionuclide examination verified the gastro-duodenal reflux in 28 infants (87,5%), while the X-ray examination proved it in 18 (56,25%). Combined use of the two methods enhanced the positive results to 93,75%. Additional information was also obtained for the causes and complications of gastro-duodenal reflux. Dynamic gastro-esophageal scintigraphy is a practicable, noninvasive and physiological method with low radiation load for demonstration of gastro-esophageal reflux in infants

  10. Iodine-123 scintigraphy in the evaluation of pediatric thyroid disorders: a ten year experience

    International Nuclear Information System (INIS)

    Paltiel, H.J.; Summerville, D.A.; Treves, S.T.

    1992-01-01

    Between 1978 and 1987, we studied 280 children with iodine-123 ( 123 I) scintigraphy. Indications for scintigraphy included hypothyroidism, neck masses, hyperthyroidism, and miscellaneous reasons. Scintigraphy was helpful in distinguishing anatomic from functional causes of hyothyroidism. It reliably identified the location of the thyroid gland in patients with neck masses. The functional status of thyroid nodules was readily assessed and was important in directing further treatment. Scintigraphy added little to the management of children with post-irradiation hypothyroidism without a palpable nodule, patients with Hashimoto thyroiditis or Graves disease when the clinical diagnosis was straightforward. (orig./GDG)

  11. Iodine-123 scintigraphy in the evaluation of pediatric thyroid disorders: a ten year experience

    Energy Technology Data Exchange (ETDEWEB)

    Paltiel, H.J.; Summerville, D.A.; Treves, S.T. (Children' s Hospital, Boston, MA (United States). Div. of Nuclear Medicine Harvard Medical School, Boston, MA (United States))

    1992-08-01

    Between 1978 and 1987, we studied 280 children with iodine-123 ([sup 123]I) scintigraphy. Indications for scintigraphy included hypothyroidism, neck masses, hyperthyroidism, and miscellaneous reasons. Scintigraphy was helpful in distinguishing anatomic from functional causes of hyothyroidism. It reliably identified the location of the thyroid gland in patients with neck masses. The functional status of thyroid nodules was readily assessed and was important in directing further treatment. Scintigraphy added little to the management of children with post-irradiation hypothyroidism without a palpable nodule, patients with Hashimoto thyroiditis or Graves disease when the clinical diagnosis was straightforward. (orig./GDG).

  12. Use of 99mTc-HMPAO-leucocyte scintigraphy coupled to 99mTc-colloid scintigraphy in diagnosing the osteo-articular sepsis

    International Nuclear Information System (INIS)

    Darlas, Y.; Pegoix, M.; Filmont, J.E.; Leclercq, S.; Rosas, M.H.; Agostini, D.; Aubriot, J.H.; Bouvard, G.

    1997-01-01

    The object of this study was the scintigraphic diagnosis of osseous sepsis based on the absence of congruence between leucocytic and colloidal fixations and the evaluation of the effect of coupling between the scintigraphies (sc) with leucocytes (A) and colloids (B) on the diagnosis feasibility index of this technique. Seventy four patients, 97 sc were divided into two groups according to the scintigraphic technique [(A) only]: 35 sc; [(A) and (B)]: 62 sc. [Prosthesis: 48 patients, 68 sc. Osteitis: 26 patients, 29 sc]. The scintigraphies were performed as follows: (A) autologous leucocytes labelled by 250 - 300 MBq of 99m Tc-HMPAO, with planar incidences (15 min), 3 - 4 hours after injection and (B) Labelled nano-colloids labelled by 180 - 200 MBq of 99m Tc, the same incidences, 30 min after injection. The delay between (A) and (B): 48 hours. The final diagnosis of sepsis: bacteriological and histologic criteria after biopsies and/or clinical, biological and radiological evolution. The comparison between the two groups is given in a table in terms of prevalence, sensitivity and specificity, using the χ2 and Fisher tests. In conclusion, the scintigraphy by 99m Tc-HMPAO-leucocyte is a sensitive method (Se ∼ 90%) for the diagnosis of osseous sepsis and coupled to the scintigraphy by 99m Tc-colloids allow obtaining a high specificity (Sp ≥ 90%) by reducing the number of falsely positive diagnoses

  13. Gallium/sup 67/ scintigraphy in fibrinous pericarditis associated with bacterial endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Martin, P; Verhas, M; Devriendt, J; Goffin, Y

    1982-04-01

    An 80-year-old man presented with pyrexia, progressive cardiac failure and inflammation. A diagnosis of pericarditis associated with bacterial endocarditis was suggested from Gallium 67 scintigraphy and confirmed at autopsy. This case of fibrinous pericarditis without effusion could not be diagnosed by echography or routine cardiopulmonary scintigraphy.

  14. Unknown and abnormal accumulation in the chest in bone scintigraphy

    International Nuclear Information System (INIS)

    Maruyama, Toshiaki; Takeuchi, Masashi; Tokunaga, Koji; Maeda, Yoichi; Hasegawa, Kazuhiko.

    1979-01-01

    In scintigraphies of forty patients with hemiplegia following appoplexia, focal abnormal accumulations in the chest region were seen in bone scintigraphies of four patients. These hot accumulations could be neither rib fracture, rib metastases, nor abnormal calcium accumulation. A mechanism of these accumulation remains to undicided. We believe that this phenomena is related to abnormal bone metabolism in hemiplegial condition. (author)

  15. Bone scintigraphy and tenofovir-induced osteomalacia in chronic hepatitis B

    International Nuclear Information System (INIS)

    Hoe, Alex khoo cheen; Feng, Lee Yeong

    2017-01-01

    Tenofovir, used in the treatment of chronic hepatitis B and HIV, is known for its side effects on the kidneys and bones. We share interesting images of a patient with tenofovir-induced osteomalacia on Technetium-99 m hydroxymethyelene (Tc-99 m HDP) bone scintigraphy. Pattern recognition of this bone scintigraphy and correlation with the clinical history is essential to avoid misdiagnosis

  16. Bile ascites in adults. Diagnosis using hepatobiliary scintigraphy and paracentesis

    International Nuclear Information System (INIS)

    Nagle, C.E.; Fink-Bennett, D.; Freitas, J.E.

    1985-01-01

    Hepatobiliary scintigraphy has been recognized as a useful diagnostic tool in detecting the presence and site of bile leaks. The authors report a case of bile ascites secondary to a postsurgical biliary leak, the scintigraphic findings in bile ascites, and the potential use of paracentesis, in combination with hepatobiliary scintigraphy, in confirming the presence of bile ascites and a bile leak

  17. Bone scintigraphy and tenofovir-induced osteomalacia in chronic hepatitis B

    Energy Technology Data Exchange (ETDEWEB)

    Hoe, Alex khoo cheen; Feng, Lee Yeong [Dept. of Nuclear Medicine, Penang Hospital, Georgetown (Malaysia)

    2017-06-15

    Tenofovir, used in the treatment of chronic hepatitis B and HIV, is known for its side effects on the kidneys and bones. We share interesting images of a patient with tenofovir-induced osteomalacia on Technetium-99 m hydroxymethyelene (Tc-99 m HDP) bone scintigraphy. Pattern recognition of this bone scintigraphy and correlation with the clinical history is essential to avoid misdiagnosis.

  18. Diagnosis of thyroid lymphoma and follow-up evaluation using Ga-67 scintigraphy

    International Nuclear Information System (INIS)

    Nishiyama, Yoshihiro; Yamamoto, Yuka; Yokoe, Koiku; Satoh, Katashi; Ohkawa, Motoomi

    2003-01-01

    A strong association between malignant lymphoma and Hashimoto's thyroiditis has frequently been reported. However, it is difficult to detect the lymphomatous transformation of Hashimoto's thyroiditis in the early stage. The purpose of the present study was to examine the usefulness of 67 Ga scintigraphy in the diagnosis and evaluation of the therapeutic effects during follow-up, in patients with a suspected diagnosis of primary thyroid lymphoma. Twenty-five patients who were suspected of having primary thyroid lymphoma and had undergone 67 Ga scintigraphy were studied. 67 Ga planar scintigraphy was performed 72 hours after injection of 67 Ga-citrate. The degree and pattern of 67 Ga accumulation were graded visually. Histopathology on biopsy examination revealed thyroid lymphoma in 17 and Hashimoto's thyroiditis in 8 patients. Abnormal accumulation of 67 Ga in the thyroid was seen in all of the 17 thyroid lymphoma cases with additional mediastinal and abdominal involvement in one. Fifteen of 17 thyroid lymphoma patients also underwent 67 Ga scintigraphy 2-4 weeks after chemotherapy and/or radiotherapy. All 15 patients showed diminishing 67 Ga accumulation and a good clinical course. In one patient with local recurrence, abnormal accumulation could be depicted by follow-up scintigraphy. However, diffuse or enlarged accumulation in the thyroid was seen in all of the 8 Hashimoto's thyroiditis cases. The degree of abnormal accumulation in the thyroid in clinically active phase thyroiditis was more intense than that in the chronic phase thyroiditis. 67 Ga scintigraphy was helpful to confirm the diagnosis of thyroid lymphoma and to evaluate the therapeutic effects during follow-up. However, 67 Ga scintigraphy may not always distinguish thyroid lymphoma from Hashimoto's thyroiditis, especially the active phase of the disease. (author)

  19. Unusual False Positive Radioiodine Uptake on 131I Whole Body Scintigraphy in Three Unrelated Organs with Different Pathologies in Patients of Differentiated Thyroid Carcinoma: A Case Series

    International Nuclear Information System (INIS)

    Ranade, Rohit; Pawar, Shwetal; Mahajan, Abhishek; Basu, Sandip

    2016-01-01

    Three cases with unusual false positive radioiodine uptake in three different organs and pathologies (infective old fibrotic lesion in the lung, simple liver cyst, and benign breast lesion) on iodine-131 ( 131 I) whole body scintigraphy. Clinicoradiological correlation was undertaken in all three cases and the pathologies were ascertained. In all the three cases, single-photon emission computerized tomography-computed tomography (SPECT-CT) and ancillary imaging modalities were employed and were helpful in arriving at the final diagnosis

  20. The role of Tl-201 total body scintigraphy in follow up of thyroid carcinoma

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Delprat, C.C.; Marcuse, H.R.

    1985-01-01

    To evaluate the reliability of the procedure T1-201 total body scintigraphy was performed in 294 patients (449 studies) after total thyroidectomy for thyroid carcinoma. Results were correlated with I-131-scintigraphy and tumor-marker levels (Tgb or Calcitonin/CEA). T1-201 total body scintigraphy was negative in 196 patients with no evidence of disease. T1-201-scintigraphy correctly detected tumor localizations in 24 of 30 patients with I-131-positive metastases. In 28 patients T2-201 total body scintigraphy revealed metastases which did not concentrate I-131. Histology/cytology confirmed thyroid carcinoma metastases in 16 patients and other pathology in 5 cases. 9 of 18 patients with medullary thyroid carcinoma (I-131-negative) had elevated Calcitonin/CEA-levels. The T1-201 scintigram was positive in 8 of these patients. Comparison of T1-201, I-131 and tumor markers showed that only combined use of these parameters provide complete reliability. The authors conclude that T1-201 total body scintigraphy is useful in follow up of thyroid carcinoma, especially when a discrepancy of the other parameters exists and particularly in medullary carcinoma. In long term follow up of patients who are unsuspected of disease after successful therapy for thyroid carcinoma one can rely on T1-201 total body scintigraphy in combination with tumor marker assays

  1. Scintigraphy, pH measurement and radiography in the evaluation of gastroesophageal reflux

    International Nuclear Information System (INIS)

    Kaul, B.; Petersen, H.; Grette, K.; Erichsen, H.; Myrvold, H.E.

    1985-01-01

    Scintigraphy as a diagnostic tool has been explored in 69 patients with gastroesophageal reflux (GER) symptoms and endoscopic esophagitis. In all subjects the presence of reflux was also evaluated by radiography and intraesophageal pH measurements (standard acid reflux test). The overall sensitivity of scintigraphy (85.5%) was significantly higher than those of radiography (27.5%) and pH measurements (69.5%). Scintigraphy was performed with normal saline and with acidified orange juice as the transport medium for the isotope 99mTc. The yield of positive scintigrams was higher (22.3 to 61.1%, depending on the grade of endoscopic esophagitis) with the latter variant. Moreover, demonstration of spontaneous reflux was greatly facilitated by the acid scintigraphy. This was particularly obvious in the grade I esophagitis, in which the freqency of spontaneous reflux with saline method was 3.4% and with acid medium 34/3%. Reflux (induced or spontaneous) was seen in 22 normal control subjects with the saline method, and in 1 subject only with the acid method. On the basis of these findings it is concluded that scintigraphy, especially the acid variant of the technique, is a valuable diagnostic procedure in GER disease

  2. Improving the accuracy of myocardial perfusion scintigraphy results by machine learning method

    International Nuclear Information System (INIS)

    Groselj, C.; Kukar, M.

    2002-01-01

    Full text: Machine learning (ML) as rapidly growing artificial intelligence subfield has already proven in last decade to be a useful tool in many fields of decision making, also in some fields of medicine. Its decision accuracy usually exceeds the human one. To assess applicability of ML in interpretation the results of stress myocardial perfusion scintigraphy for CAD diagnosis. The 327 patient's data of planar stress myocardial perfusion scintigraphy were reevaluated in usual way. Comparing them with the results of coronary angiography the sensitivity, specificity and accuracy for the investigation was computed. The data were digitized and the decision procedure repeated by ML program 'Naive Bayesian classifier'. As the ML is able to simultaneously manipulate of whatever number of data, all reachable disease connected data (regarding history, habitus, risk factors, stress results) were added. The sensitivity, specificity and accuracy for scintigraphy were expressed in this way. The results of both decision procedures were compared. With ML method 19 patients more out of 327 (5.8 %) were correctly diagnosed by stress myocardial perfusion scintigraphy. ML could be an important tool for decision making in myocardial perfusion scintigraphy. (author)

  3. Thallium scintigraphy during dobutamine infusion: nonexercise-dependent screening test for coronary disease

    International Nuclear Information System (INIS)

    Mason, J.R.; Palac, R.T.; Freeman, M.L.; Virupannavar, S.; Loeb, H.S.; Kaplan, E.; Gunnar, R.M.

    1984-01-01

    Exercise thallium scintigraphy has proven to be a sensitive method for detecting coronary artery disease (CAD). However, early redistribution of thallium and inadequate exercise can reduce its sensitivity. In this study, dobutamine was infused in incremental doses (5, 10, 15, and 20 micrograms/kg/min) in 24 patients being evaluated for chest pain. Thallium scintigraphy was completed during the maximum dose of dobutamine tolerated and repeated 4 hours later. Significant CAD was present in 16 patients; the remaining eight had normal coronaries. Exercise ECG was obtained in 23 patients. During dobutamine thallium scintigraphy, reversible perfusion defects occurred in 15 of 16 CAD and in one of eight non-CAD patients, resulting in a sensitivity of 94% and a specificity of 87%. Exercise ECG had a sensitivity of 60% and a specificity of 63%. We conclude that: (1) dobutamine thallium scintigraphy appears to be a sensitive method for detecting significant CAD and provided a more sensitive screening test than exercise ECG; (2) dobutamine thallium scintigraphy is especially useful in patients who cannot exercise; and (3) because imaging occurs during dobutamine infusion, the problem of early redistribution may be mitigated

  4. Scintigraphy, pH measurement and radiography in the evaluation of gastroesophageal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Kaul, B.; Petersen, H.; Grette, K.; Erichsen, H.; Myrvold, H.E.

    1985-01-01

    Scintigraphy as a diagnostic tool has been explored in 69 patients with gastroesophageal reflux (GER) symptoms and endoscopic esophagitis. In all subjects the presence of reflux was also evaluated by radiography and intraesophageal pH measurements (standard acid reflux test). The overall sensitivity of scintigraphy (85.5%) was significantly higher than those of radiography (27.5%) and pH measurements (69.5%). Scintigraphy was performed with normal saline and with acidified orange juice as the transport medium for the isotope 99mTc. The yield of positive scintigrams was higher (22.3 to 61.1%, depending on the grade of endoscopic esophagitis) with the latter variant. Moreover, demonstration of spontaneous reflux was greatly facilitated by the acid scintigraphy. This was particularly obvious in the grade I esophagitis, in which the freqency of spontaneous reflux with saline method was 3.4% and with acid medium 34/3%. Reflux (induced or spontaneous) was seen in 22 normal control subjects with the saline method, and in 1 subject only with the acid method. On the basis of these findings it is concluded that scintigraphy, especially the acid variant of the technique, is a valuable diagnostic procedure in GER disease.

  5. Clinical evaluation of 67Ga gut accumulation in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kobayashi, Hidetoshi; Ohno, Akiko; Watanabe, Youichi; Ishigaki, Takeo.

    1994-01-01

    Accumulation of 67 Ga in gut was evaluated in 67 Ga scintigraphy retrospectively in 30 patients (32 examinations). TIBC and UIBC were examined in all patients on the day when their scintigraphies were performed. Blood transfusion or Fe administration 2 months before 67 Ga scintigraphies were not carried out in any patient. Fifty percents (6/12) of male, and 40% (8/20) of female patients showed 67 Ga accumulation in gut. There was significant correlation between 67 Ga accumulation in gut and low ion-saturation ratio for transferrin. Excretion of 67 Ga bound with transferrin from liver was thought to be an important factor of 67 ga accumulation in gut. (author)

  6. Fracture healing: Quantitative three-phase bone scintigraphy as a prognostic factor

    International Nuclear Information System (INIS)

    Dodig, D.; Kasal, B.; Kragic-Pranic, A.; Predic, P.

    2002-01-01

    Aim: Careful clinical examination and conventional radiography, together with other standard methods for evaluation of bone fracture healing, are frequently inconclusive. Furthermore, it is difficult to predict the complications of healing on the basis of clinical and radiographic findings only. Bone scintigraphy plays an important role in detecting bone fractures. This method is very sensitive, but not enough specific. The aim of this work was to evaluate the role of three-phase bone scintigraphy in the healing prognosis of long bone fractures. Material and Methods: We evaluated the three elements (perfusion, blood pool and static image) of three-phase bone scintigraphy in early prognosis of the course of fracture healing in patients with fractures of femur or tibia. Three-phase bone scintigraphy was performed in 73 patients. The patients were divided into 4 groups according to X-ray and clinical examination: 1) Non operated patients with stable fracture, 2) Operated patients with unstable fracture (infection), 3) Fractures with delayed union, 4) Patients with pseudoarthrosis. Using region of interest (ROI) method we compared the activity on the site of fracture with the activity on the symmetrical place in the healthy bone. The relative indices for each group of patients and for each element of three-bone scintigraphy were calculated in order to make possible the follow up of the fracture healing and to obtain data for prognosis and evaluation of possible complications. Results: The most valuable results were obtained by quantitative analysis of perfusion data immediately after trauma and 2-3 weeks later. Our results show a high diagnostic accuracy in identifying infection by perfusion scintigrams immediately after trauma. The perfusion indices obtained immediately and after 2-3 weeks could predict delayed union after the trauma. Quantitative analysis of blood pool phase gave no data of clinical significance in distinguishing various pathologies. Conclusion: Our

  7. Value of bone scintigraphy in psoriasis

    International Nuclear Information System (INIS)

    Nakayama, Chikashi; Nakata, Hajime; Kimoto, Tatsuya; Nakayama, Takashi; Yokomizo, Yu

    1982-01-01

    We performed bone scintigraphy on 16 cases of psoriasis to evaluate its possible value in this disease and obtained the following results: 1) Bone scintigraph was abnormal in 15 of 16 cases and the frequent association of arthritis in psoriasis was confirmed. 2) Abnormal uptake on bone scintigraph was noted in various joints including peripheral joints of extremities, sternoclavicular joint, shoulder and rib. Abnormality of sacroiliac joint or ankle was less frequent than previously reported. 3) Findings of bone scintigraph were not necessarily related with clinical symptoms or laboratory data. Abnormal uptake was also noted in many joints whose X-ray examinations were negative. Bone scintigraphy thus seems to be useful in early detection of arthritis and to become an initial therapeutic indicator of arthritis in psoriasis. (author)

  8. In Vitro Ability of Currently Available Oximes to Reactivate Organophosphate Pesticide-Inhibited Human Acetylcholinesterase and Butyrylcholinesterase

    OpenAIRE

    Kamil Musilek; Kamil Kuca; Daniel Jun; Lucie Musilova

    2011-01-01

    We have in vitro tested the ability of common, commercially available, cholinesterase reactivators (pralidoxime, obidoxime, methoxime, trimedoxime and HI-6) to reactivate human acetylcholinesterase (AChE), inhibited by five structurally different organophosphate pesticides and inhibitors (paraoxon, dichlorvos, DFP, leptophos-oxon and methamidophos). We also tested reactivation of human butyrylcholinesterase (BChE) with the aim of finding a potent oxime, suitable to serve as a “pseudocatalytic...

  9. Sequential functional imaging with technetium-99m hexakis-2-methoxyisobutylisonitrile and indium-111 octreotide: can we predict the response to chemotherapy in small cell lung cancer?

    International Nuclear Information System (INIS)

    Moretti, J.L.; Caglar, M.; Boaziz, C.; Caillat-Vigneron, N.; Morere, J.F.

    1995-01-01

    A case of small cell lung carcinoma (SCLC) demonstrating uptake on functional indium-111 octreotide scintigraphy is presented. Technetium-99m hexakis-2-methoxyisobutylisonitrile (MIBI) scintigraphy clearly delineated an absence of radionuclide uptake at the tumour site. This suggested the presence of multidrug resistance-mediated P glycoprotein (Pgp) on tumour cells, which recognizes certain chemotherapeutic agents as well as MIBI as a substrate and avoids radionuclide concentration. Following three courses of chemotherapy, the patient failed to improve and eventually died. This case demonstrates the importance of functional images, which have the potential to predict the outcome in response to chemotherapy. (orig.)

  10. 99mTc-stannous colloid white cell scintigraphy in childhood inflammatory bowel disease.

    Science.gov (United States)

    Peacock, Kenneth; Porn, Ute; Howman-Giles, Robert; O'Loughlin, Edward; Uren, Roger; Gaskin, Kevin; Dorney, Stuart; Kamath, Ramanand

    2004-02-01

    99mTc-Labeled white cell scintigraphy (WCS) has been used for the investigation of inflammatory bowel disease (IBD) in adults, but data on children are limited. The most common agent used is (99m) Tc-hexamethylpropyleneamine oxime (HMPAO); however, this agent has limitations. In a retrospective study, we assessed the use of (99m)Tc-stannous colloid WCS for the initial evaluation of children with suspected IBD. Diagnostic, endoscopic, and contrast radiography results were retrospectively collected from the medical records. Two experienced nuclear physicians unaware of the patient data interpreted the WCS results, with agreement reached by consensus. Statistical analysis was performed on the ability of WCS to detect active disease and localize it topographically and on a comparison of diagnostic methods, using a combination of clinical features and endoscopy as the reference standard. Between 1996 and 1999, 64 patients (35 male and 29 female; mean age, 12.5 y; age range, 2-19 y) had WCS performed, with IBD subsequently diagnosed in 34 patients. (99m)Tc-Stannous colloid WCS had an 88% sensitivity, 90% specificity, and 8.8 likelihood ratio for initial investigation of IBD. Agreement was poor for topographic localization of disease. Small-bowel series had a 75% sensitivity, 50% specificity, and 1.5 likelihood ratio for detecting endoscopic disease of the terminal ileum and proximal colon. Our results confirm that WCS is a useful imaging technique for the initial evaluation of patients with suspected IBD. (99m)Tc-Stannous colloid had results at least comparable to those of other WCS agents, and in children, (99m)Tc-stannous colloid WCS should be preferred in view of lower cost, shorter preparation time, and the smaller blood volumes required.

  11. Cerebral uptake and retention of 99Tcsup(m)-hexamethylpropyleneamine oxime (99Tcsup(m)-HM-PAO)

    International Nuclear Information System (INIS)

    Holmes, R.A.; Chaplin, S.B.; Royston, K.G.; Missouri Univ., Columbia

    1985-01-01

    A new radiopharmaceutical, 99 Tcsup(m)-hexamethylpropyleneamine oxime ( 99 Tcsup(m)-HM-PAO) is described. This agent displays considerable promise for imaging cerebral blood flow. In studies in rats and one human volunteer, 99 Tcsup(m)-HM-PAO demonstrates good brain uptake, prolonged retention of activity in the brain, and slow regional redistribution. These properties suggest that this new radiopharmaceutical is ideal for single photon emission tomographic (SPECT) imaging of cerebral blood flow. (author)

  12. The role of bone scintigraphy in detecting child abuse.

    Science.gov (United States)

    Conway, J J; Collins, M; Tanz, R R; Radkowski, M A; Anandappa, E; Hernandez, R; Freeman, E L

    1993-10-01

    This review of diagnostic imaging in cases of suspected child abuse characterizes the significant differences between bone scintigraphy and x-ray evaluation, describes the advantages and disadvantages of each modality, postulates on the specific mechanisms of injury that produce the characteristic scintigraphic findings, and emphasizes the influences that scintigraphic studies have on the medical, social, and legal aspects of child abuse. The major advantages of bone scintigraphy are its increased sensitivity (25% to 50%) in detecting evidence of soft tissue as well as bone trauma in child abuse. Furthermore, it is postulated that the specific mechanisms of inflicting the trauma relate to the patient's size and are characterized by bone scintigraphy. During fits of anger or frustration, the perpetrator of child abuse grasps the small infant or child by the thorax during the shaking activity. This produces characteristic rib injuries. The older and heavier child is more likely to be grabbed by the extremities, which produces periosteal injuries manifested as characteristic abnormal localizations in the diaphyses of the extremities. The roentgenograms of these injuries are frequently normal. The importance of bone scintigraphy is its complementary nature in defining and characterizing the extent and severity of trauma from child abuse. Such findings have direct bearing on the medical, social, and legal outcomes for the abused child. The quality of scintigraphic imaging is important, requiring the use of magnification techniques in the infant. The interpretation of the scintigraphic images depends on an understanding of the mechanisms by which the radionuclide localizes in bone. The same traumatic incident can lead to decreased, normal, or increased localization at the trauma site. Radionuclide scintigraphy is a complementary rather than competitive imaging modality to X-ray evaluation in the diagnosis and management of physical child abuse.

  13. Detection of thrombi by 111In-oxine platelet scintigraphy

    International Nuclear Information System (INIS)

    Makino, Katsutoshi; Yamamuro, Masashi; Ichikawa, Takehiko; Futagami, Yasuo; Konishi, Tokuji; Nakano, Takeshi; Takezawa, Hideo

    1985-01-01

    For 52 patients with cardiac disease and 11 patients with vascular disease, In-111-oxine platelet scintigraphy was performed to assess its clinical usefulness for detecting thrombi. Using Hayashida's method, platelets were separated in 43 ml peripheral blood, washed and labeled with 1 mCi In-111-oxine. In addition to planar images in the anterior, 45 deg left anterior oblique and left lateral views, single photon emission computed tomography (SPECT) was performed in some cases by rotating a dual gamma camera 24 and 72 hours after labeled platelet injection. The functions of platelet and coagulability were examined 36 hours after the injection of labeled platelets. Medical therapy was not changed during this study. Intracardiac thrombi were documented in 16 of 52 cases with cardiac disease and intravascular thrombi in 10 cases with vascular disease by angiography, CT and two-dimensional echocardiography. Positive images were obtained in 10 cases with cardiac disease and in eight cases with vascular disease by scintigraphy. Therefore, sensitivity, specificity, and overall accuracy were 63 %, 100 % and 88 % in intracardiac thrombi; 80 %, 100 % and 82 % in intravascular thrombi; and totally 69 %, 100 % and 87 %, respectively. In the detection of intracardiac thrombi by scintigraphy, the sensitivity seemed to be lower and the specificity higher than those by other graphic studies. In 52 cases with cardiac disease, five out of six cases with false negative images had received antiplatelet and/or anticoagulant drugs, and in these cases, platelet and coagulation functions tended to be decreased compared with those of true positive cases or true negative cases. We conclude that positive images in scintigraphy indicate the existence of growing thrombi, and that In-111-oxine platelet scintigraphy has clinical usefulness, not only for detecting thrombi, but for estimating platelet activity and effect of medical therapy. (author)

  14. A comparative study between pancreas scintigraphy and endoscopic retrograde pancreatic parenchymography

    International Nuclear Information System (INIS)

    Onishi, Ryuji; Yoshimoto, Shinjiro; Tadokoro, Jiro; Sugimura, Kazuo; Ushio, Keiji.

    1980-01-01

    Fifteen patients with a suspected pancreatic disease were examined by both pancreatic scintigraphy using 75 Se-selenomethionine and endoscopic retrograde pancreatic parenchymography (ERPP). These two diagnostic procedures have different mechanism of parenchymal imaging. In scintigraphy, uptake of 75 Se-selenomethionine depends on metabolic activity of the pancreatic parenchyma while in ERPP visualization of pancreatic tissue depends on patency of the pancreatic duct, permeability of the periductal tissue and cell function of the pancreatic parenchyma. In comparative study, excellent concordance of findings occurred in 11 of 15 cases. An interesting difference of finding occurred in a case of chronic pancreatitis who had marked involvement of pancreatic duct. In this case, scintigraphy visualized entire pancreas though uptake of the radioisotope was diffusely diminished, while ERPP failed to visualize the body and tail. Another interesting finding was difference of image of pancreatic body. In scintigraphy, a relatively cold area is often seen in body of the pancreas in normal subjects and explained as a result of anatomical thinning of the organ by impression of vertebra and major blood vessels. In our series, 5 cases showed such a finding in scintigraphy, while in ERPP 4 of these 5 cases showed no evidence of localized thinning of the organ. A combination of these two imaging procedures of pancreatic parenchyma with different mechanism provides more detailed anatomical and pathophysiological condition of the pancreatic diseases. (author)

  15. Value of gallium 67 citrate scintigraphy in ophthalmology

    International Nuclear Information System (INIS)

    Ivanez-Alloschery, Monique.

    1978-01-01

    For ophthalmologists scintigraphy appears as a simple method to detect endoocular or endoorbital abnormalities. However none of the many scintigraphic methods described seems reliable enough to be used alone. One of the latest isotopic explorations using gallium 67 citrate, a tracer considered tumour-tropic might be able to solve this problem. The aim of this work is to judge the value of the method in the diagnosis of malignant endoocular and endoorbital tumours on the basis of 24 anatomoclinical observations. It may be concluded from this study that ocular gallium 67 citrate scintigraphy, which gave no clearly positive results at all but some doubtful results in the case of endoocular tumours more than 5 mm in diameter, is to be rejected; fluorescein angiography and ocular echograhy provide more elements for an accurate etiological diagnosis. Orbital scintigraphy on the other hand seems to be a necessary complement to a tomodensitometric examination since both methods offer diagnostic information without systematic recurse to carotid arteriography or orbital phlebography, sometimes dangerous for the patient [fr

  16. Evaluation of bone diseases using dynamic bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kumano, Machiko; Tamura, Kenji; Hamada, Tatsumi; Ishida, Osamu [Kinki Univ., Higashi-Osaka, Osaka (Japan); Kajita, Akiyoshi

    1983-12-01

    Dynamic bone scintigraphy with sup(99m)Tc-EHDP was performed on 96 patients with various bone diseases. The dynamic scintigrams obtained were then used to aid in the differential diagnosis of malignant (49 cases) and benign (8 cases) diseases. Short-term local deposition of the tracer in all cases of malignant bone diseases was observed in vascular (10-40 sec. after injection), and blood pool (1-3 min. after injection) phases. In the cases of malignant bone tumors where osteosclerotic lesions were present, tracer accumulation appeared in the blood pool phase. If osteolytic lesions were present, accumulation appeared in the vascular phase, and when the lesion was larger than 2 cm, accumulation was frequently found in the arterial phase. Scintigraphic differentiation of early primary and metastatic bone tumors from other lesions was facilitated by performing the dynamic scintigraphy with sup(99m)Tc-EHDP. Dynamic bone scintigraphy also allowed early diagnosis of avascular necrosis (14 cases) prior to the appearance of minimally abnormal X-ray findings, especially in cases of corticosteroid-induced necrosis.

  17. Role of scintigraphy in urinary tract infection

    International Nuclear Information System (INIS)

    Conway, J.J.

    1988-01-01

    There is controversy regarding the role of radiological imaging for urinary tract infection (UTI). The gold standard has been the intravenous pyelogram (IVP). Yet, the IVP has a very limited value with only about 25% of children with pyelonephritis demonstrating abnormalities. Ultrasound (US) has recently been advocated as a replacement for the poorly sensitive and poorly specific IVP. However, comparative studies between US and IVP indicate only an equivalent sensitivity and specificity. Cortical scintigraphy with Technetium-99m glucoheptonate (99mTc GH) or 99mTc dimercaptosuccinic acid (99mTc DMSA) has also been advocated as a means of differentiating parenchymal (pyelonephritis) from nonparenchymal (lower UTI) involvement in UTI. The clinical presentation may be misleading especially in the infant and child in whom an elevated temperature, flank pain, shaking chills, or an elevated sedimentation rate are often lacking. The clinician attempts to localize the site of infection for it has a direct bearing upon the therapy. A collecting system infection can often be eradicated with a single oral dose of an appropriate antibiotic, whereas renal parenchymal involvement requires IV therapy for an extended interval. Cortical scintigraphy can localize the site of infection with a high degree of accuracy. Recent studies report a sensitivity of 86% and specificity of 81% of pyelonephritis. This is in contrast to the IVP with a sensitivity of only 24% and US with a sensitivity of only 42%. The scintigraphic appearance of parenchymal infection of the kidney is a spectrum of minimal to gross defects reflecting the degree of histologic involvement that spans from a mild infection to frank abscess. Cortical scintigraphy can be used to monitor the evolution of scarring following infection. Cortical scintigraphy with 99mTc DMSA or 99mTc GH is the method of choice for the initial evaluation of UTI. 37 references

  18. A case of muscular sarcoidosis diagnosed by gallium-67 scintigraphy and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sohn, Hyung Sun; Kim, Euy Neyng

    1999-01-01

    Gallium-67 scintigraphy is helpful in the assessment of active extrapulmonary sarcoidosis. Muscular involvement of sarcoidosis is often asymptomatic or nonspecific, and laboratory examinations do not provide convincing evidence of muscular involvement. We report a case of muscular sarcoidosis, which was detected by gallium-67 scintigraphy. In a patient who was suffering from fever and arthalgia of knee joint, gallium-67 scintigraphy showed mediastinal and hilar involvement of sarcoidosis with unexpected extensive muscular uptake. Magnetic resonance imaging revealed the detailed depiction of intramuscular infiltration of sarcoid granuloma. Gallium-67 scintigraphy is useful in detecting inflammatory muscular involvement of sarcoidosis as well as other multiorgan involvement

  19. Right ventricular visualization by Tl-201 myocardial scintigraphy in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Masashi; Matsuzawa, Yukinori; Handa, Kenjiro; Yoshimura, Kazuhiko [Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine

    1993-04-01

    Tl-201 myocardial scintigraphy was performed in 130 patients with chronic obstructive pulmonary disease (COPD) to evaluate right ventricular hypertrophy, and the clinical significance of this method was studied. Tl-201 uptake ratios of the right ventricle, which represents the ratio of total counts of the right ventricle to counts of the administered dose of Tl-201, was higher in COPD, especially in pulmonary emphysema and B type COPD by Burrows classification than in controls. The grade of visualization of the right ventricle by visual assessment (RVV) was marked (+++) in only a few cases and moderate (++) in many cases (more than 80%) in all diseases except bronchial asthma. The incidence of right ventricular hypertrophy by electrocardiogram, right-sided heart failure and marked dyspnea (Hugh-Jones 4[center dot]5) were very low in cases with RVV grade ++ and very high in cases with +++. The grade of RVV was related to the severity of pulmonary perfusion impairment, although in diffuse panbronchiolitis the RVV was relatively slight compared with the impairment of perfusion. May parameters of pulmonary function such as %VC, FEV1.0%, RV/TLC, V25, %DLCO, Raw, [Delta]N[sub 2] and PaO[sub 2] showed abnormal values in patients with RVV grade of (++) or (+++) in all diseases except bronchial asthma. In COPD, Tl-201 myocardial scintigraphy seems to be useful for assessment of right ventricular overloading, and for follow-up observation and differentiation between cor pulmonale and right ventricular hypertrophy secondary to cardiac diseases by observing Tl-201 uptake of the lung and left ventricle. (author).

  20. Right ventricular visualization by Tl-201 myocardial scintigraphy in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Masashi; Matsuzawa, Yukinori; Handa, Kenjiro; Yoshimura, Kazuhiko

    1993-01-01

    Tl-201 myocardial scintigraphy was performed in 130 patients with chronic obstructive pulmonary disease (COPD) to evaluate right ventricular hypertrophy, and the clinical significance of this method was studied. Tl-201 uptake ratios of the right ventricle, which represents the ratio of total counts of the right ventricle to counts of the administered dose of Tl-201, was higher in COPD, especially in pulmonary emphysema and B type COPD by Burrows classification than in controls. The grade of visualization of the right ventricle by visual assessment (RVV) was marked (+++) in only a few cases and moderate (++) in many cases (more than 80%) in all diseases except bronchial asthma. The incidence of right ventricular hypertrophy by electrocardiogram, right-sided heart failure and marked dyspnea (Hugh-Jones 4·5) were very low in cases with RVV grade ++ and very high in cases with +++. The grade of RVV was related to the severity of pulmonary perfusion impairment, although in diffuse panbronchiolitis the RVV was relatively slight compared with the impairment of perfusion. May parameters of pulmonary function such as %VC, FEV1.0%, RV/TLC, V25, %DLCO, Raw, ΔN 2 and PaO 2 showed abnormal values in patients with RVV grade of (++) or (+++) in all diseases except bronchial asthma. In COPD, Tl-201 myocardial scintigraphy seems to be useful for assessment of right ventricular overloading, and for follow-up observation and differentiation between cor pulmonale and right ventricular hypertrophy secondary to cardiac diseases by observing Tl-201 uptake of the lung and left ventricle. (author)

  1. Value of renal cortical scintigraphy in children with acute pyelonephritis

    International Nuclear Information System (INIS)

    Paul, A.K.; Miah, M.S.R.; Rahman, H.A.; Hasan, M.H.

    2004-01-01

    Purpose: Acute pyelonephritis is a major cause of morbidity in children with urinary tract infection and can result in irreversible renal scarring leading to hypertension and end-stage renal disease. Tc-99m-dimercaptosuccinic acid (DMSA) scintigraphy is the imaging modality of choice for the detection of acute pyelonephhfis and renal scarfing. This study evaluated the importance of renal cortical scintigraphy to identify children at risk from renal damage due to acute pyelonephritis. Methods: Forty-nine children (ages 9 months to 11 years) with urinary tract infection having positive urine culture were studied. A DMSA scan was performed within 72 hours of receiving antibiotic during acute infection. Single or multiple areas of varying degrees of diminished cortical uptake or diffusely decreased uptake in an enlarged kidney was considered for the diagnosis of acute pyelonephrifis. Follow-up scintigraphy was done at 6 months of initial scan in children with acute pyelonephritis documented by DMSA scan. Renal scarring was considered if the affected kidney shows cortical thinning or focal cortical defect with loss of volume or become small kidney. Children with known renal tract abnormalities were excluded from the study. RESULTS: Twenty-seven children (55%) wine considered acute pyelonephritis by DMSA scintigraphy and the abnormality was bilateral in 17(63%) cases and unilateral in 10(37%) cases. Among these 44 abnormal kidneys, scintigraphy showed solitary defect in 29 kidneys, multiple defects in 6 kidneys and diffuse decreased uptake in 9 kidneys. Of them, twenty children were available for follow-up evaluation and scintigraphy demonstrated complete recovery in 21 of 34 (62%) kidneys and renal scarfing in 13 of 34 (38%) kidneys. Renal scarring was found in 5 of 7 kidneys (71%) with diffuse decreased uptake, 2 of 5 kidneys (40%) with multiple cortical defect and 6 of 22 (27%) with single focal detect. Conclusion: The scintigraphic pattern of acute pyelonephritis

  2. Renal scintigraphy following angiotensin-converting enzyme inhibition in the diagnosis of renovascular hypertension (captopril scintigraphy)

    International Nuclear Information System (INIS)

    Sfakianakis, G.N.; Sfakianakis, E.; Bourgoignie, J.

    1988-01-01

    There is definitely a niche for an accurate test for the diagnosis of RVH; more important, there is a need for a predictive test to help select patients suitable for revascularization procedures as opposed to medical treatment. All current tests have less than optimal results. Captopril scintigraphy warrants evaluation. It is important, however, to approach the test with a full understanding of its theoretical potentials on the basis of current clinical experience. Several options, techniques, and combinations are possible, given the availability of more than one radiopharmaceutical. The purpose of this chapter is to: (a) briefly review RVH and its pathophysiology, with emphasis on the need to establish the diagnosis, lateralize the abnormality, and decide about the mode of treatment; (b) review the current knowledge about converting-enzyme inhibitors; (c) analyze the handling of the different radiopharmaceuticals by the RVH-related kidney with and without pharmacologic intervention; and (d) compare and critically examine proposed protocols for captopril scintigraphy

  3. Can hydroxylamine be a more potent nucleophile for the reactivation of tabun-inhibited AChE than prototype oxime drugs? An answer derived from quantum chemical and steered molecular dynamics studies.

    Science.gov (United States)

    Lo, Rabindranath; Ganguly, Bishwajit

    2014-07-29

    Organophosphorus nerve agents are highly toxic compounds which strongly inhibit acetylcholinesterase (AChE) in the blood and in the central nervous system (CNS). Tabun is one of the highly toxic organophosphorus (OP) compounds and is resistant to many oxime drugs formulated for the reactivation of AChE. The reactivation mechanism of tabun-conjugated AChE with various drugs has been examined with density functional theory and ab initio quantum chemical calculations. The presence of a lone-pair located on the amidic group resists the nucleophilic attack at the phosphorus center of the tabun-conjugated AChE. We have shown that the newly designed drug candidate N-(pyridin-2-yl)hydroxylamine, at the MP2/6-31+G*//M05-2X/6-31G* level in the aqueous phase with the polarizable continuum solvation model (PCM), is more effective in reactivating the tabun-conjugated AChE than typical oxime drugs. The rate determining activation barrier with N-(pyridin-2-yl)hydroxylamine was found to be ∼1.7 kcal mol(-1), which is 7.2 kcal mol(-1) lower than the charged oxime trimedoxime (one of the most efficient reactivators in tabun poisonings). The greater nucleophilicity index (ω(-)) and higher CHelpG charge of pyridinylhydroxylamine compared to TMB4 support this observation. Furthermore, we have also examined the reactivation process of tabun-inhibited AChE with some other bis-quaternary oxime drug candidates such as methoxime (MMB4) and obidoxime. The docking analysis suggests that charged bis-quaternary pyridinium oximes have greater binding affinity inside the active-site gorge of AChE compared to the neutral pyridinylhydroxylamine. The peripheral ligand attached to the neutral pyridinylhydroxylamine enhanced the binding with the aromatic residues in the active-site gorge of AChE through effective π-π interactions. Steered molecular dynamics (SMD) simulations have also been performed with the charged oxime (TMB4) and the neutral hydroxylamine. From protein-drug interaction

  4. The usefulness of bone marrow scintigraphy in the detection of bone metastasis from prostatic cancer

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Fukunaga, Masao; Morita, Rikushi

    1985-01-01

    A combination study of bone and bone marrow scintigraphy was performed on 25 pts with prostatic cancer, and, in order to study the usefulness in the diagnosis of bone metastasis, the findings of 2 scintigraphies were compared with those of skeletal roentgenography. Out of the 18 cases with the hot spots of sup(99m)Tc-MDP in the lower lumbar spine or/and the pelvic bone, 8 showed normal bone marrow scintigrams which were eventually proved to have degenerative changes of the spine accompanied by aging. On the other hand, nine cases of the ten, who had accumulation defects on the bone marrow scintigrams were finally proved having bone metastasis. All six cases with extensive bone metastases shown by bone scintigraphy with sup(99m)Tc-MDP, demonstrated multiple accumulation defects on bone marrow scintigraphy with sup(99m)Tc-sulfur colloid. In conclusion, bone marrow scintigraphy was thought to be helpful in distinguishing the metastatic lesions from the benign spinal degenerative changes in the cases with suspicions bone involvement and in evaluating equivocal lesions in the pelvis. Therefore, it was shown that, in the detection and diagnosis of bone metastasis from prostatic cancer, bone scintigraphy alone was insufficient, and that combination with bone marrow scintigraphy was found to be useful. (author)

  5. Cartilage Calcification Mimics Polychondritis in Bone Scintigraphy

    Directory of Open Access Journals (Sweden)

    Hasan Atilgan

    2013-04-01

    Full Text Available 58 year-old male patient with sternal pain was referred to our Nuclear Medicine Clinic for bone scintigraphy for 2.5 months. Markedly increased activity accumulation in the first bilateral sternocostal junction and increased activity accumulations in 3rd, 4th, 5th sternocostal junctions and lateral portion of inferior part of corpus sterni were seen in late static images without increased perfusion and hyperemia. Soft tissue density and lytic lesions were seen bilaterally in bilateral first costa, sternocostal joints and in right side of xiphoid in his 3D computed tomography (CT. Sternocostal lesions that were seen in bone scintigraphy and CT, was reported as normal in biopsy.

  6. Quantitative evaluation of bone scintigraphy in prostate cancer

    International Nuclear Information System (INIS)

    Yamamoto, Yasushi

    2017-01-01

    This paper described the quantitative evaluation of bone scintigraphy that is used in the inspection of the bone-metastasis of prostate cancer. In advanced prostate cancer, bone scintigraphic examination with technetium 99m methylenediphosphonate (complex compound) is indispensable. Since bone metastasis hardly involves soft tissue, the morphological evaluation of soft tissue cancer cannot be used as a reference. Therefore, quantitative evaluation peculiar to bone scintigraphy has been developed. Following the visual evaluation that began in the 1980's, a technique considering highly integrated parts and areas of images was proposed in the 1990's. The computer-aided diagnosis (CAD) software that automated the manual analysis of the above technique was developed in the 2010's. In order to evaluate the usefulness of quantitative evaluation based on bone CAD, the authors performed bone scintigraphy for 42 patients, who were diagnosed as castration-resistant prostate cancer (CRPC) in 2004 to 2011 and received DEC therapy for 4 months. When bone CAD analysis was performed, it was found that the therapeutic effect could not be determined earlier than the judgement using the increase of PSA antigen. Recently quantitative analysis shifted from bone scintigraphy to bone SPECT (single photon emission computed tomography), and papers have also been published since the 2010s. In bone SPECT, the quantitative function of SUV (standardized uptake value) was equipped, and in the clinical use case of SUV, SUV increase was seen earlier than the increase of PSA antigen. The evidences are expected to be accumulated in the future. (A.O.)

  7. Noninvasive external cardiac pacing for thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Feldman, M.D.; Warren, S.E.; Gervino, E.V.

    1988-01-01

    Improvements in noninvasive external cardiac pacing have led to a technique with reliable electrical capture and tolerable patient discomfort. To assess the use of this modality of pacing in combination with thallium scintigraphy as a noninvasive pacing stress test, we applied simultaneous noninvasive cardiac pacing, hemodynamic monitoring, and thallium-201 scintigraphy in 14 patients undergoing cardiac catheterization for chest pain syndromes. Two patients had normal coronary arteries, while the remaining 12 had significant coronary artery disease. Thallium scintigraphic responses to pacing were compared to routine exercise thallium stress testing in nine of these 14 patients. All patients were noninvasively paced to more than 85% of the age-predicted maximum heart rate. Twelve patients demonstrated reversible thallium defects, which corresponded in 11 cases to significant lesions seen on coronary angiography. Of nine patients who underwent both pacing and exercise thallium stress tests, comparable maximal rate-pressure products were achieved. Moreover, thallium imaging at peak pacing and during delayed views did not differ significantly from exercise thallium scintigraphy. A limiting factor associated with the technique was local patient discomfort, which occurred to some degree in all patients. We conclude that noninvasive external cardiac pacing together with thallium scintigraphy is capable of detecting significant coronary artery disease and may be comparable to routine exercise thallium stress testing. This new modality of stress testing could be useful in patients unable to undergo the exercise required for standard exercise tolerance testing, particularly if improvements in the technology can be found to reduce further the local discomfort

  8. Femoral chondrosarcoma discovered by SPECT-T.D.M. osseous scintigraphy; Chondrosarcome femoral decouvert par scintigraphie osseuse SPECT-TDM

    Energy Technology Data Exchange (ETDEWEB)

    Bourahla, K.; Nguyen, L.; Rolling, P.; Schott, A.; Di Salvo, R. [CLCC Paul-Strauss, Strasbourg, (France)

    2009-05-15

    Objectives: the SPECT/T.D.M. imaging can allow a quick diagnosis direction by the concomitant exploitation of scintigraphy data and morphological data brought by the T.D.M.. We present the case of a chondrosarcoma diagnosed in nuclear medicine thanks to the exploitation of the data supplied by the SPECT/T.D.M. that allowed to direct rapidly the later explorations while reducing the time of the patient coverage. Conclusions: A knowledge of the most characteristic morphological data allows to give some diagnosis at first sight during the scintigraphy explorations coupled SPECT/T.D.M. and this in the interest of the patient by reducing his coverage while including the nuclear doctor more broadly in some diagnosis approaches previously remote from his reach. (N.C.)

  9. Retrospective Analysis of Indication of Bone Scintigraphy Performed in Our Clinic

    Directory of Open Access Journals (Sweden)

    Fusun Aydogan

    2014-03-01

    Full Text Available Aim: Bone scintigraphy is one of the commonly used radionuclide imaging and it is successfully used in the diagnosis and follow-up of many diseases. The aim of this study is to determine the indications and filming protocols of bone scintigraphy which was performed in our clinic. Material and Method: Two hundred and fifty two patients (132 male, 120 female who was performed bone scintigprapy in our clinic between December 2011 and June 2013 included the study. Mean age was 50.1±20.2 years. Scintigraphic protocols were made in two ways as late static whole body imaging and three-phase bone scintigraphy according to the type of the diseases. Indications of scintigraphies and scintigraphic protocols were detected. Results: Bone scintigraphy was performed for diagnosis and monitoring of metastatic bone disease to 102 patients (40,5 %, for orthopedic applications to 57 patients (22,6 %, for diagnosis and monitoring of primary bone tumors to 29 patients (11,5 %, for diagnosis of osteomyelitis to 17 patients (6,7 %, for differential diagnosis of infection and loosening of the prosthesis to 12 patients (4,8 %, investigate the viability of the graft in 14 patients (4,6 %, for rheumatologic diseases to 9 patients (3,6 %, for investigate the pathological vertebral fractures and osteoporosis to 4 patients (1,6 %, for diagnosis the metabolic bone disease to 2 patients (0,8 %, for diagnosis of otitis externa to 5 patients (1,98 % and for for suspicion of malignancy to 1 patient (0,4 %. Late static whole body imaging protocol was applied to 136 patients (54 % and three-phase imaging protocol was applied to 116 patients (46 %. Discussion: The most common use of bone scintigraphy is the diagnosis and follow-up of metastatic bone disease. It is followed by reasons such as orthopedic applications, monitoring and diagnosis of primary bone tumors and diagnosis of osteomyelitis.

  10. Evaluation of arterial embolization therapy for hepatocellular carcinoma by liver scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Ohishi, Hajime; Ohue, Shoichi; Ide, Khoichi [Nara Medical Univ., Kashihara (Japan)

    1983-02-01

    After arterial embolization therapy, two cases of hepatocellular carcinoma were followed up by RI scintigraphy, and the results were compared with those of angiography. A correlation between changes in /sup 67/Ga-citrate distribution and angiographical picture was found. This suggested that tumor scintigraphy is useful for follow-up observation after arterial embolization therapy.

  11. Esophageal scintigraphy and pH monitoring in adults with gastroesophageal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Jouin, H.; Chamouard, P.; Baumann, R. and others

    1987-10-01

    Thirty-seven adults with gastroesophageal reflux were explored by oesophageal scintigraphy and pH monitoring (three hours postprandial). Scintigraphy was less frequently positive than pH test in gastroesophageal reflux (81% versus 57%) with a significant difference. It is suggested that postprandial pH monitoring is reliable in the initial assessment of symptomatic gastroesophageal reflux.

  12. Dynamic scintigraphy of esophagus in gastroesophageal reflux patients

    International Nuclear Information System (INIS)

    Foltynova, V.; Brousil, J.; Belohlavek, O.; Rehak, F.; Pafko, P.

    1988-01-01

    Scintigraphic examination of esophagus was performed in 24 patients with clinical signs of gastroesophageal reflux (GER). The results were divided into five different types of clinical findings representing different disorders in esophageal motility. The results were compared with radiological examinations, pH-metry and endoscopy. Sensitivity of the scintigraphy was 94.1%, specificity 50%, and accuracy 89.5%. The results are much better than those of radiological examinations and are comparable with pH-metry. Esophageal scintigraphy a good noninvasive method providing information about the motility of the esophagus not obtainable with other methods. (author). 8 figs., 9 refs

  13. Diagnostic value of technetium pyrophosphate bone scintigraphy. Study of 277 patients

    International Nuclear Information System (INIS)

    Sainte-Croix, Annick.

    1975-01-01

    277 bone scintigraphs were carried out with 99m technetium pyrophosphate and an attempt was made, on the basis of this experience, to define the advantages and limits of the technique. 99m technetium pyrophosphate seems to be the isotope most suitable for bone scintigraphy. The scintillation camera bone scintigraphic examination is simple, allowing the whole skeleton to be explored in a relatively short time, and above all harmless since the total irradiation to which the organism is exposed throughout is no more than 0.07 rad. The broadest field of application of bone scintigraphy appears to be cancer: in 45 cases out of 66 it revealed bone metastases invisible radiologically and in 28 cases out of 90 the number of metastases observed was greater than that shown by X-rays. In 11 cases however radiologically visible bone metastases were not detected by scintigraphy. In spite of this reservation we consider bone scintigraphy to be a valuable technique, more sensitive than X-ray examinations in the detection of bone metastases of cancers [fr

  14. Quantitative bone and 67Ga scintigraphy in the differentiation of necrotizing external otitis from severe external otitis

    International Nuclear Information System (INIS)

    Uri, N.; Gips, S.; Front, A.; Meyer, S.W.; Hardoff, R.

    1991-01-01

    Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 ± 0.16 in patients with NEO and 1.08 ± 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 ± 0.24 in NEO patients and 1.05 ± 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative scoring method (scores 0 to +4), according to the intensity of the radiopharmaceutical uptake. This method was found to be inferior in the diagnosis of NEO compared with the quantitative method. We conclude that lesion-to-nonlesion ratios greater than 1.5 and 1.3 on bone and gallium 67 scintigraphy, respectively, are indicative of NEO. Quantitative bone scintigraphy, which is quicker to perform, may be used as a single imaging modality for the diagnosis of NEO

  15. Myocardial Scintigraphy in the Evaluation of Cardiac Events in Patients without Typical Symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Smanio, Paola Emanuela Poggio, E-mail: pgmsmanio@gmail.com; Silva, Juliana Horie; Holtz, João Vitor; Ueda, Leandro; Abreu, Marilia; Marques, Carlindo; Machado, Leonardo [Instituto Dante Pazzanese de Cardiologia, São Paulo, SP - Brazil Mailing (Brazil)

    2015-08-15

    Cardiovascular disease is a leading cause of death in the world and in Brazil. Myocardial scintigraphy is an important noninvasive method for detecting ischemia in symptomatic patients, but its use in asymptomatic ones or those with atypical symptoms is yet to be defined. To verify the presence of major cardiac events in asymptomatic patients or those with atypical symptoms (atypical chest pain or dyspnea) that underwent myocardial scintigraphy (MS), over a period of 8 years. Secondary objectives were to identify cardiac risk factors associated with myocardial scintigraphy abnormalities and possible predictors for major cardiac events in this group. This was a retrospective, observational study using the medical records of 892 patients that underwent myocardial scintigraphy between 2005 and 2011 and who were followed until 2013 for assessment of major cardiac events and risk factors associated with myocardial scintigraphy abnormalities. Statistical analysis was performed by Fisher’s exact test, logistic regression and Kaplan-Meyer survival curves, with statistical significance being set at p ≤ 0.05. Of the total sample, 52.1% were men, 86.9% were hypertensive, 72.4% had hyperlipidemia, 33.6% were diabetic, and 12.2% were smokers; 44.5% had known coronary artery disease; and 70% had high Framingham score, 21.8% had moderate and 8% had low risk. Of the myocardial scintigraphies, 58.6% were normal, 26.1% suggestive of fibrosis and 15.3% suggestive of ischemia. At evolution, 13 patients (1.5%) had non-fatal myocardial infarction and six individuals (0.7%) died. The group with normal myocardial scintigraphy showed longer period of time free of major cardiac events, non-fatal myocardial infarction (p = 0.036) and death. Fibrosis in the myocardial scintigraphy determined a 2.4-fold increased risk of non-fatal myocardial infarction and five-fold higher risk of death (odds ratio: 2.4 and 5.7, respectively; p = 0.043). The occurrence of major cardiac events in 8 years

  16. Brain scintigraphy in patients with hydrocephalus

    International Nuclear Information System (INIS)

    Kadowaki, Hirotaka; Imanaga, Hirohisa; Kitamura, Koichi

    1975-01-01

    Brain scintigraphy is a simple, innocuous and valuable diagnostic method. Particulary in children, in order to minimize damage by examination, brain scintigraphy should be the first examination for patients, before other diagnostic methods such as cerebral angiography and pneumoencephalography. In the 3 years between Jan. 1970 and Dec. 1972, 235 children under the age of 15 years had brain scintigraphy with sup(99m)Tc pertechnetate at the Tokyo Women's Medical College Hospital. The authors especially attended to the findings of scintigrams in children with hydrocephalus. 29 children with non-neoplastic hydrocephalus were scanned with sup(99m)Tc pertechnetate: noncommunicating hydrocephalus; 9; hydroencephalodysplasia; 4; Chiari Arnold malformation; 1; cranium bifidum; 2; communicating hydrocephalis; 13. In noncommunicating hydrocephalus, the midline structure on the scintigram appeared thicker than the normal, because activity in the superior sagittal sinus was relatively high compared to the reduction of activity in the enlarged ventricles. In cases of very severe hydrocephalus, the basal ganglia was shown as a clear hot spot on the scintigram, because R. I. activity in the basal ganglia was relatively high compared to the reduction of R. I. activity in the enlarged ventricles. In cases of hydroencephalodysplasia, the midline structure on the scintigram shifted to the side opposite the dysplasia, as the result of pressure from a large CSF collection. In cases of cranium bifidum, the scintigram showed an elevation of the transverse sinus and the confluent sinus. (auth.)

  17. Comparison of dipyridamole-echocardiography with dipyridamole-thallium scintigraphy for the diagnosis of myocardial ischemia

    International Nuclear Information System (INIS)

    Perin, E.C.; Moore, W.; Blume, M.; Hernandez, G.; Dhekne, R.; DeCastro, C.M.

    1991-01-01

    After an intravenous infusion of dipyridamole (0.56 mg/kg), the authors performed both echocardiography and thallium scintigraphy in 63 patients who were referred for known or suspected coronary artery disease. Of those patients, 25 returned for coronary arteriography within 1 month after the tests, thus forming the study group for this report. Sensitivity for detection of coronary artery disease, when analyzed region-by-region, was 80% for thallium scintigraphy and 57% for echocardiography, whereas specificity was 85% and 98%, respectively. When evaluating individual patients for the presence or absence of ischemia, they found a sensitivity of 95% for scintigraphy and 58% for echocardiography; corresponding specificities were 50% and 100%. By using arteriography as the gold standard for comparison, it appears that thallium scintigraphy has a significantly higher sensitivity but lower specificity for the detection of coronary artery disease than does echocardiography. Echocardiography may, however, be a useful adjunct to thallium scintigraphy in the evaluation of patients with coronary artery disease

  18. Somatostatin receptor scintigraphy in patients with cat-scratch disease

    International Nuclear Information System (INIS)

    Krause, R.; Schnedl, W.J.; Hoier, S.; Piswanger-Soelkner, C.; Lipp, R.W.; Daxboeck, F.; Reisinger, E.C.

    2006-01-01

    Aim: somatostatin receptor scintigraphy images various neoplastic, granulomatous, and auto-immun diseases. Cat-scratch disease in an infectious granulomatous disease usually affecting the lymphnodes. It is not known whether cat-scratch disease provides positive somatostatin receptor scintigrams. Patients, methods: twelve patients with lymphadenitis and suspected cat-scratch disease were investigated by immunofluorescence antibody testing and somatostatin receptor scintigraphy. Suppurated lymphnodes were extracted or drained and Bartonella henselae specific PCR was then performed. Results: eleven of 12 patients showed IgG antibodies against B. henselea. SRS showed positive scintigraphic results in 6 of 11 patients with CSD. B. henselae DNA was detected in tissue of lymphnodes from 4 of 5 patients with lymphnode extraction or lymphnode drainage. SRS demonstrated positive scintigrams in all patients with a positive PCR. In one patient with suspected CSD SRS was negative as well as antibody testing. Conclusion: somatostatin receptor scintigraphy correlated with positive Bartonella henselae specific PCR tests and positive Bartonella henselae specific antibody tests in patients with CSD. (orig.)

  19. Finding of region of interest in radioisotope scintigraphy's images

    International Nuclear Information System (INIS)

    Glazs, A.; Lubans, A.

    2003-01-01

    The paper is about some problems, which arise, when physicians try to make diagnosis, using information from pictures, which are obtained at radioisotope scintigraphy. The algorithm of obtaining pictures' sets (called GFR) is described in this paper. The possible mistakes in diagnosis are also described. One reason of the mistakes is wrong detection the investigated organ's location. The new method is suggested for detection of organ's location in radioisotope scintigraphy's images' sets. Using of dynamic curves of pixels' intensities is suggested for solving of this problem. It is shown, why using of maximums of such curves is impossible for finding of the investigated organ's location in radioisotope scintigraphy's images sets. The using of integral expression is suggested to solve the problem. The suggested method allows finding and selecting of investigated organ's location in image's sequences (correction is not available in the existing methods). The results of using this method are present. The method can work fully automatically or with manual setting of threshold. (authors)

  20. In-111-labeled leukocyte scintigraphy in postoperative joint infection

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Uetani, Masataka; Aziz, A.; Hayashi, Kuniaki

    2000-01-01

    To evaluate the role of In-111-labeled leukocyte scintigraphy in the patients with suspected postoperative joint infection, 41 scintigraphic examinations were performed in 24 patients. Scintigrams were interpreted by the degree of accumulation of labeled leukocytes, and were classified into 3 groups: positive, intermediate, and negative. In the cases of positive leukocyte scans, definite diagnosis of infection was made in all cases except one. In the cases of negative scans, there was no evidence of infection. In 13 cases, leukocyte scintigrams were interpreted in conjunction with bone scintigrams. Definite diagnosis of infection was made in all of the cases with positive combined leukocyte/bone scan, and there was no evidence of infection in cases with negative combined leukocyte/bone scan. This study demonstrates that In-111-labeled leukocyte scintigraphy is a useful method in diagnosis of postoperative joint infection, and accuracy of the examination improves when combined with bone scintigraphy. (author)