WorldWideScience

Sample records for overcoming antigen masking

  1. Overcoming antigen masking of anti-amyloidbeta antibodies reveals breaking of B cell tolerance by virus-like particles in amyloidbeta immunized amyloid precursor protein transgenic mice

    Directory of Open Access Journals (Sweden)

    Ugen Kenneth E

    2004-06-01

    Full Text Available Abstract Background In prior work we detected reduced anti-Aβ antibody titers in Aβ-vaccinated transgenic mice expressing the human amyloid precursor protein (APP compared to nontransgenic littermates. We investigated this observation further by vaccinating APP and nontransgenic mice with either the wild-type human Aβ peptide, an Aβ peptide containing the "Dutch Mutation", E22Q, or a wild-type Aβ peptide conjugated to papillomavirus virus-like particles (VLPs. Results Anti-Aβ antibody titers were lower in vaccinated APP than nontransgenic mice even when vaccinated with the highly immunogenic Aβ E22Q. One concern was that human Aβ derived from the APP transgene might mask anti-Aβ antibodies in APP mice. To test this possibility, we dissociated antigen-antibody complexes by incubation at low pH. The low pH incubation increased the anti-Aβ antibody titers 20–40 fold in APP mice but had no effect in sera from nontransgenic mice. However, even after dissociation, the anti-Aβ titers were still lower in transgenic mice vaccinated with wild-type Aβ or E22Q Aβ relative to non-transgenic mice. Importantly, the dissociated anti-Aβ titers were equivalent in nontransgenic and APP mice after VLP-based vaccination. Control experiments demonstrated that after acid-dissociation, the increased antibody titer did not cross react with bovine serum albumin nor alpha-synuclein, and addition of Aβ back to the dissociated serum blocked the increase in antibody titers. Conclusions Circulating human Aβ can interfere with ELISA assay measurements of anti-Aβ titers. The E22Q Aβ peptide vaccine is more immunogenic than the wild-type peptide. Unlike peptide vaccines, VLP-based vaccines against Aβ abrogate the effects of Aβ self-tolerance.

  2. The CD3-zeta chimeric antigen receptor overcomes TCR Hypo-responsiveness of human terminal late-stage T cells.

    Directory of Open Access Journals (Sweden)

    Gunter Rappl

    Full Text Available Adoptive therapy of malignant diseases with tumor-specific cytotoxic T cells showed remarkable efficacy in recent trials. Repetitive T cell receptor (TCR engagement of target antigen, however, inevitably ends up in hypo-responsive cells with terminally differentiated KLRG-1(+ CD57(+ CD7(- phenotype limiting their therapeutic efficacy. We here revealed that hypo-responsiveness of CMV-specific late-stage CD8(+ T cells is due to reduced TCR synapse formation compared to younger cells. Membrane anchoring of TCR components contributes to T cell hypo-responsiveness since dislocation of galectin-3 from the synapse by swainsonine restored both TCR synapse formation and T cell response. Transgenic expression of a CD3-zeta signaling chimeric antigen receptor (CAR recovered hypo-responsive T cells to full effector functions indicating that the defect is restricted to TCR membrane components while synapse formation of the transgenic CAR was not blocked. CAR engineered late-stage T cells released cytokines and mediated redirected cytotoxicity as efficiently as younger effector T cells. Our data provide a rationale for TCR independent, CAR mediated activation in the adoptive cell therapy to avoid hypo-responsiveness of late-stage T cells upon repetitive antigen encounter.

  3. Overcoming challenges

    Medline Plus

    Full Text Available ... breastfeeding Overcoming challenges Common questions about breastfeeding and pain Breastfeeding checklist: How to get a good latch Finding ... myths Overcoming challenges Common questions about breastfeeding and pain Breastfeeding checklist: How to get a good latch Finding ...

  4. Overcoming challenges

    Medline Plus

    Full Text Available ... section Back to section menu It's Only Natural Planning ahead Breastfeeding and baby basics Making breastfeeding work ... It's Only Natural Overcoming challenges It's Only Natural Planning ahead Addressing breastfeeding myths Overcoming challenges Common questions ...

  5. Overcoming challenges

    Medline Plus

    Full Text Available ... Disease and Stroke HIV and AIDS Mental Health Pain Pregnancy Reproductive Health Sexual Health Sexually Transmitted Infections ... breastfeeding Overcoming challenges Common questions about breastfeeding and pain Breastfeeding checklist: How to get a good latch ...

  6. Overcoming challenges

    Medline Plus

    Full Text Available ... menu It's Only Natural Planning ahead Breastfeeding and baby basics Making breastfeeding work for you Addressing breastfeeding ... in the African-American community Incredible facts about babies, breastmilk, and breastfeeding Overcoming challenges Common questions about ...

  7. Overcoming challenges

    Medline Plus

    Full Text Available ... and mission Leadership Programs and activities In your community Funding opportunities Internships and jobs View all pages ... breastfeeding myths Breastfeeding myths in the African-American community Incredible facts about babies, breastmilk, and breastfeeding Overcoming ...

  8. Overcoming challenges

    Medline Plus

    Full Text Available ... facts about babies, breastmilk, and breastfeeding Overcoming challenges Common questions about breastfeeding and pain Breastfeeding checklist: How to get a good latch Finding support It takes a village: Building ...

  9. Overcoming challenges

    Medline Plus

    Full Text Available ... breastfeeding means to them. Subscribe To receive Breastfeeding email updates Enter email Submit Overcoming challenges Breastfeeding has a long list ... breastfeeding means to them. Subscribe To receive Breastfeeding email updates Enter email Submit All material contained on ...

  10. Overcoming challenges

    Medline Plus

    Full Text Available ... into your life Breastfeeding in daily life: At home and in public Laws that support breastfeeding 10 ... and jobs View all pages in this section Home It's Only Natural Overcoming challenges It's Only Natural ...

  11. Clay Mask Workshop

    Science.gov (United States)

    Gamble, David L.

    2012-01-01

    Masks can represent so many things, such as emotions (happy, sad, fearful) and power. The familiar "comedy and tragedy" masks, derived from ancient Greek theater, are just one example from mask history. Death masks from the ancient Egyptians influenced the ancient Romans into creating similar masks for their departed. Masks can represent many…

  12. Overcoming challenges

    Medline Plus

    Full Text Available ... Contact Us Blog Popular topics Vision and mission Leadership Programs and activities In your community Funding opportunities Internships and jobs View all pages in this section Home It's Only Natural Overcoming challenges It's Only Natural Planning ahead Addressing breastfeeding myths ...

  13. Overcoming challenges

    Medline Plus

    Full Text Available ... we are What we do Programs and activities Work with us Contact Us Blog Popular topics Vision and mission Leadership Programs and activities In your community Funding opportunities Internships and jobs View all pages in this section Home It's Only Natural Overcoming challenges It's Only Natural ...

  14. Smoke Mask

    Science.gov (United States)

    2003-01-01

    Smoke inhalation injury from the noxious products of fire combustion accounts for as much as 80 percent of fire-related deaths in the United States. Many of these deaths are preventable. Smoke Mask, Inc. (SMI), of Myrtle Beach, South Carolina, is working to decrease these casualties with its line of life safety devices. The SMI personal escape hood and the Guardian Filtration System provide respiratory protection that enables people to escape from hazardous and unsafe conditions. The breathing filter technology utilized in the products is specifically designed to supply breathable air for 20 minutes. In emergencies, 20 minutes can mean the difference between life and death.

  15. venice: Mask utility

    Science.gov (United States)

    Coupon, Jean

    2018-02-01

    venice reads a mask file (DS9 or fits type) and a catalogue of objects (ascii or fits type) to create a pixelized mask, find objects inside/outside a mask, or generate a random catalogue of objects inside/outside a mask. The program reads the mask file and checks if a point, giving its coordinates, is inside or outside the mask, i.e. inside or outside at least one polygon of the mask.

  16. Overcoming Absence

    DEFF Research Database (Denmark)

    Paldam, Camilla Skovbjerg

    2017-01-01

    In this chapter, I address the rhetoric of modern love correspondence – its various purposes, modes of communication, and meta-reflections on writing and media – from the beginning of the 20th century till today. I analyze how love and the beloved are mediated in the articulated desire and longing...... of love letters, and how love letters are used as a medium to overcome absence. I also reflect on the material status of love letters in relation to the technological development and subsequently the replacement of traditional letters by their digital counterparts such as email, text messages and real...

  17. Visual masking & schizophrenia

    Directory of Open Access Journals (Sweden)

    Michael H. Herzog

    2015-06-01

    Full Text Available Visual masking is a frequently used tool in schizophrenia research. Visual masking has a very high sensitivity and specificity and masking paradigms have been proven to be endophenotypes. Whereas masking is a powerful technique to study schizophrenia, the underlying mechanisms are discussed controversially. For example, for more than 25 years, masking deficits of schizophrenia patients were mainly attributed to a deficient magno-cellular system (M-system. Here, we show that there is very little evidence that masking deficits are magno-cellular deficits. We will discuss the magno-cellular and other approaches in detail and highlight their pros and cons.

  18. Binaural masking level differences in nonsimultanuous masking

    NARCIS (Netherlands)

    Kohlrausch, A.G.; Fassel, R.; Gilkey, R.H.; Anderson, T.R.

    1997-01-01

    This chapter investigates the extent to which binaural unmasking occurs with nonsimultaneous presentation of masker and signal, particularly in forward masking. The majority of previous studies that addressed this question found that there is a substantial binaural masking level difference (BMLD) in

  19. Magnesium Presence Prevents Removal of Antigenic Nuclear-Associated Proteins from Bovine Pericardium for Heart Valve Engineering.

    Science.gov (United States)

    Dalgliesh, Ailsa J; Liu, Zhi Zhao; Griffiths, Leigh G

    2017-07-01

    Current heart valve prostheses are associated with significant complications, including aggressive immune response, limited valve life expectancy, and inability to grow in juvenile patients. Animal derived "tissue" valves undergo glutaraldehyde fixation to mask tissue antigenicity; however, chronic immunological responses and associated calcification still commonly occur. A heart valve formed from an unfixed bovine pericardium (BP) extracellular matrix (ECM) scaffold, in which antigenic burden has been eliminated or significantly reduced, has potential to overcome deficiencies of current bioprostheses. Decellularization and antigen removal methods frequently use sequential solutions extrapolated from analytical chemistry approaches to promote solubility and removal of tissue components from resultant ECM scaffolds. However, the extent to which such prefractionation strategies may inhibit removal of antigenic tissue components has not been explored. We hypothesize that presence of magnesium in prefractionation steps causes DNA precipitation and reduces removal of nuclear-associated antigenic proteins. Keeping all variables consistent bar the addition or absence of magnesium (2 mM magnesium chloride hexahydrate), residual BP ECM scaffold antigenicity and removed antigenicity were assessed, along with residual and removed DNA content, ECM morphology, scaffold composition, and recellularization potential. Furthermore, we used proteomic methods to determine the mechanism by which magnesium presence or absence affects scaffold residual antigenicity. This study demonstrates that absence of magnesium from antigen removal solutions enhances solubility and subsequent removal of antigenic nuclear-associated proteins from BP. We therefore conclude that the primary mechanism of action for magnesium removal during antigen removal processes is avoidance of DNA precipitation, facilitating solubilization and removal of nuclear-associated antigenic proteins. Future studies are

  20. Masks in Pedagogical Practice

    Science.gov (United States)

    Roy, David

    2016-01-01

    In Drama Education mask work is undertaken and presented as both a methodology and knowledge base. There are numerous workshops and journal articles available for teachers that offer knowledge or implementation of mask work. However, empirical examination of the context or potential implementation of masks as a pedagogical tool remains…

  1. Keeping African Masks Real

    Science.gov (United States)

    Waddington, Susan

    2012-01-01

    Art is a good place to learn about our multicultural planet, and African masks are prized throughout the world as powerfully expressive artistic images. Unfortunately, multicultural education, especially for young children, can perpetuate stereotypes. Masks taken out of context lose their meaning and the term "African masks" suggests that there is…

  2. 2013 mask industry survey

    Science.gov (United States)

    Malloy, Matt

    2013-09-01

    A comprehensive survey was sent to merchant and captive mask shops to gather information about the mask industry as an objective assessment of its overall condition. 2013 marks the 12th consecutive year for this process. Historical topics including general mask profile, mask processing, data and write time, yield and yield loss, delivery times, maintenance, and returns were included and new topics were added. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the mask industry. While each year's survey includes minor updates based on feedback from past years and the need to collect additional data on key topics, the bulk of the survey and reporting structure have remained relatively constant. A series of improvements is being phased in beginning in 2013 to add value to a wider audience, while at the same time retaining the historical content required for trend analyses of the traditional metrics. Additions in 2013 include topics such as top challenges, future concerns, and additional details in key aspects of mask masking, such as the number of masks per mask set per ground rule, minimum mask resolution shipped, and yield by ground rule. These expansions beyond the historical topics are aimed at identifying common issues, gaps, and needs. They will also provide a better understanding of real-life mask requirements and capabilities for comparison to the International Technology Roadmap for Semiconductors (ITRS).

  3. Selective spatial attention modulates bottom-up informational masking of speech

    OpenAIRE

    Carlile, Simon; Corkhill, Caitlin

    2015-01-01

    To hear out a conversation against other talkers listeners overcome energetic and informational masking. Largely attributed to top-down processes, information masking has also been demonstrated using unintelligible speech and amplitude-modulated maskers suggesting bottom-up processes. We examined the role of speech-like amplitude modulations in information masking using a spatial masking release paradigm. Separating a target talker from two masker talkers produced a 20?dB improvement in speec...

  4. Traditional Chinese Masks Reveal Customs

    Institute of Scientific and Technical Information of China (English)

    1996-01-01

    CHINESE masks are undoubtedly an important component in the worldwide mask culture. Minority nationality masks are a major component of China’s mask culture. Traditional Chinese masks, or nuo, represent a cultural component which originated from religious rites in prehistoric times. Various types of nuo are highly valuable for studies of Chinese customs.

  5. How the global layout of the mask influences masking strength.

    Science.gov (United States)

    Ghose, Tandra; Hermens, Frouke; Herzog, Michael H

    2012-12-10

    In visual backward masking, the perception of a target is influenced by a trailing mask. Masking is usually explained by local interactions between the target and the mask representations. However, recently it has been shown that the global spatial layout of the mask rather than its local structure determines masking strength (Hermens & Herzog, 2007). Here, we varied the mask layout by spatial, luminance, and temporal cues. We presented a vernier target followed by a mask with 25 elements. Performance deteriorated when the length of the two mask elements neighboring the target vernier was doubled. However, when the length of every second mask element was doubled, performance improved. When the luminance of the neighboring elements was doubled, performance also deteriorated but no improvement in performance was observed when every second element had a double luminance. For temporal manipulations, a complex nonmonotonic masking function was observed. Hence, changes in the mask layout by spatial, luminance, and temporal cues lead to highly different results.

  6. Mask Phenomenon in Communication

    Institute of Scientific and Technical Information of China (English)

    郎丽璇

    2013-01-01

    People sometimes wear masks. Abusive expression may be used to convey love while polite words can be exchanged among enemies. This essay describes and discusses this special phenomenon in communication and analyzes the elements that con-tribute to the success of a mask communication.

  7. Binary Masking & Speech Intelligibility

    DEFF Research Database (Denmark)

    Boldt, Jesper

    The purpose of this thesis is to examine how binary masking can be used to increase intelligibility in situations where hearing impaired listeners have difficulties understanding what is being said. The major part of the experiments carried out in this thesis can be categorized as either experime......The purpose of this thesis is to examine how binary masking can be used to increase intelligibility in situations where hearing impaired listeners have difficulties understanding what is being said. The major part of the experiments carried out in this thesis can be categorized as either...... experiments under ideal conditions or as experiments under more realistic conditions useful for real-life applications such as hearing aids. In the experiments under ideal conditions, the previously defined ideal binary mask is evaluated using hearing impaired listeners, and a novel binary mask -- the target...... binary mask -- is introduced. The target binary mask shows the same substantial increase in intelligibility as the ideal binary mask and is proposed as a new reference for binary masking. In the category of real-life applications, two new methods are proposed: a method for estimation of the ideal binary...

  8. Mask materials in powderblasting

    NARCIS (Netherlands)

    Wensink, H.; Berenschot, Johan W.; Jansen, Henricus V.; Elwenspoek, Michael Curt

    1999-01-01

    Powderblasting has the opportunity to become a standard technology in micromachining. To machine small details with powderbalsting, it is necessary to use a suiabled mask. In this paper four mask types ares examined. BF400 resist foil is most suitable for standard use in powderblasting for reason of

  9. The Moody Mask Model

    DEFF Research Database (Denmark)

    Larsen, Bjarke Alexander; Andkjær, Kasper Ingdahl; Schoenau-Fog, Henrik

    2015-01-01

    This paper proposes a new relation model, called "The Moody Mask model", for Interactive Digital Storytelling (IDS), based on Franceso Osborne's "Mask Model" from 2011. This, mixed with some elements from Chris Crawford's Personality Models, is a system designed for dynamic interaction between ch...

  10. What's in a mask? Information masking with forward and backward visual masks.

    Science.gov (United States)

    Davis, Chris; Kim, Jeesun

    2011-10-01

    Three experiments tested how the physical format and information content of forward and backward masks affected the extent of visual pattern masking. This involved using different types of forward and backward masks with target discrimination measured by percentage correct in the first experiment (with a fixed target duration) and by an adaptive threshold procedure in the last two. The rationale behind the manipulation of the content of the masks stemmed from masking theories emphasizing attentional and/or conceptual factors rather than visual ones. Experiment 1 used word masks and showed that masking was reduced (a masking reduction effect) when the forward and backward masks were the same word (although in different case) compared to when the masks were different words. Experiment 2 tested the extent to which a reduction in masking might occur due to the physical similarity between the forward and backward masks by comparing the effect of the same content of the masks in the same versus different case. The result showed a significant reduction in masking for same content masks but no significant effect of case. The last experiment examined whether the reduction in masking effect would be observed with nonword masks--that is, having no high-level representation. No reduction in masking was found from same compared to different nonword masks (Experiment 3). These results support the view that the conscious perception of a rapidly displayed target stimulus is in part determined by high-level perceptual/cognitive factors concerned with masking stimulus grouping and attention.

  11. Hybrid mask for deep etching

    KAUST Repository

    Ghoneim, Mohamed T.

    2017-08-10

    Deep reactive ion etching is essential for creating high aspect ratio micro-structures for microelectromechanical systems, sensors and actuators, and emerging flexible electronics. A novel hybrid dual soft/hard mask bilayer may be deposited during semiconductor manufacturing for deep reactive etches. Such a manufacturing process may include depositing a first mask material on a substrate; depositing a second mask material on the first mask material; depositing a third mask material on the second mask material; patterning the third mask material with a pattern corresponding to one or more trenches for transfer to the substrate; transferring the pattern from the third mask material to the second mask material; transferring the pattern from the second mask material to the first mask material; and/or transferring the pattern from the first mask material to the substrate.

  12. 2012 Mask Industry Survey

    Science.gov (United States)

    Malloy, Matt; Litt, Lloyd C.

    2012-11-01

    A survey supported by SEMATECH and administered by David Powell Consulting was sent to semiconductor industry leaders to gather information about the mask industry as an objective assessment of its overall condition. The survey was designed with the input of semiconductor company mask technologists and merchant mask suppliers. 2012 marks the 11th consecutive year for the mask industry survey. This year's survey and reporting structure are similar to those of the previous years with minor modifications based on feedback from past years and the need to collect additional data on key topics. Categories include general mask information, mask processing, data and write time, yield and yield loss, delivery times, and maintenance and returns. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the mask industry. Results, initial observations, and key comparisons between the 2011 and 2012 survey responses are shown here, including multiple indications of a shift towards the manufacturing of higher end photomasks.

  13. Mask quality assessment

    Science.gov (United States)

    Regis, Larry; Paulson, Neil; Reynolds, James A.

    1994-02-01

    Product quality and timely delivery are two of the most important parameters, determining the success of a mask manufacturing facility. Because of the sensitivity of this data, however, very little is known about industry performance in these areas. Using Arthur Andersen & Co. to protect contributor identity, the authors have conducted a blind quality survey of mask shops which represents over 75% of the total merchant and captive mask volume in the US. Quantities such as return rate, plate survival yield, performance to schedule and reason for return were requested from 1988 through Q2 1993. Data is analyzed and conclusions are presented.

  14. Masked Photocathode for Photoinjector

    International Nuclear Information System (INIS)

    Qiang, Ji

    2010-01-01

    In this research note, we propose a scheme to insert a photocathode inside a photoinjector for generating high brightness electron beam. Instead of mounting the photocathode onto the electrode, a masked electrode with small hole is used to shield the photocathode from the accelerating vacuum chamber. Using such a masked photocathode will make the replacement of photocathode material very simple by rotating the photocathode behind the mask into the hole. This will significantly increase the usage lifetime of a photocathode. Furthermore, this also helps reduce the dark current or secondary electron emission from the photocathode. The hole on the mask also provides a transverse cut-off to the Gaussian laser profile which can be beneficial from the beam dynamics point of view.

  15. Gilded Silver Mask

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    This gilded silver mask from the Liao Dynasty is 31 cm long and 22.2 cm wide. The plump oval face was designed with a protruding brow ridge, narrow eyes, high-bridged nose and closed mouth. The chin is slightly round against a thin neck, the ears are long and the hair can be clearly seen from the finely carved lines. The use of masks was recorded as

  16. Masks: The Artist in Me

    Science.gov (United States)

    Skophammer, Karen

    2009-01-01

    Whether masks are made from cardboard, papier-mache, metal, wood, leather, fabric, clay or any combination of these materials, they bring out the artist in people. Young children like to wear masks when they play to pretend they were another person or animal. Masks let them fantasize and be creative. The author's students made masks representing…

  17. Orion Emergency Mask Approach

    Science.gov (United States)

    Tuan, George C.; Graf, John C.

    2009-01-01

    Emergency mask approach on Orion poses a challenge to the traditional Shuttle or Station approaches. Currently, in the case of a fire or toxic spill event, the crew utilizes open loop oxygen masks that provide the crew with oxygen to breath, but also dumps the exhaled oxygen into the cabin. For Orion, with a small cabin volume, the extra oxygen will exceed the flammability limit within a short period of time, unless a nitrogen purge is also provided. Another approach to a fire or toxic spill event is the use of a filtering emergency masks. These masks utilize some form of chemical beds to scrub the air clean of toxic providing the crew safe breathing air for a period without elevating the oxygen level in the cabin. Using the masks and a form of smoke-eater filter, it may be possible to clean the cabin completely or to a level for safe transition to a space suit to perform a cabin purge. Issues with filters in the past have been the reaction time, breakthroughs, and high breathing resistance. Development in a new form of chemical filters has shown promise to make the filtering approach feasible.

  18. Individuals and Their Masks

    Directory of Open Access Journals (Sweden)

    Belén Altuna

    2009-08-01

    Full Text Available This essay works on the opposition between face and mask, where ‘face’ is understood as that which makes every human being singular, and makes visible her or his unique worth, while ‘mask’ is understood as whatever hides that singularity, and refers to a category, stereotype or cliché. The etymological history that relates face and mask to the concept of person, and the history of modern portrait painting, which alternates representations of face and mask, both lead to a discussion with authors who diagnose a contemporary “defeat of the face” as a result of the crisis of humanism and of ethical individualism, which give meaning and dignity to that face.

  19. Concepts and applications for influenza antigenic cartography

    Science.gov (United States)

    Cai, Zhipeng; Zhang, Tong; Wan, Xiu-Feng

    2011-01-01

    Influenza antigenic cartography projects influenza antigens into a two or three dimensional map based on immunological datasets, such as hemagglutination inhibition and microneutralization assays. A robust antigenic cartography can facilitate influenza vaccine strain selection since the antigenic map can simplify data interpretation through intuitive antigenic map. However, antigenic cartography construction is not trivial due to the challenging features embedded in the immunological data, such as data incompleteness, high noises, and low reactors. To overcome these challenges, we developed a computational method, temporal Matrix Completion-Multidimensional Scaling (MC-MDS), by adapting the low rank MC concept from the movie recommendation system in Netflix and the MDS method from geographic cartography construction. The application on H3N2 and 2009 pandemic H1N1 influenza A viruses demonstrates that temporal MC-MDS is effective and efficient in constructing influenza antigenic cartography. The web sever is available at http://sysbio.cvm.msstate.edu/AntigenMap. PMID:21761589

  20. Competing for Consciousness: Prolonged Mask Exposure Reduces Object Substitution Masking

    Science.gov (United States)

    Goodhew, Stephanie C.; Visser, Troy A. W.; Lipp, Ottmar V.; Dux, Paul E.

    2011-01-01

    In object substitution masking (OSM) a sparse, temporally trailing 4-dot mask impairs target identification, even though it has different contours from, and does not spatially overlap with the target. Here, we demonstrate a previously unknown characteristic of OSM: Observers show reduced masking at prolonged (e.g., 640 ms) relative to intermediate…

  1. Overcoming job stress

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000884.htm Overcoming job stress To use the sharing features on this page, ... stay healthy and feel better. Causes of Job Stress Although the cause of job stress is different ...

  2. Geometrical superresolved imaging using nonperiodic spatial masking.

    Science.gov (United States)

    Borkowski, Amikam; Zalevsky, Zeev; Javidi, Bahram

    2009-03-01

    The resolution of every imaging system is limited either by the F-number of its optics or by the geometry of its detection array. The geometrical limitation is caused by lack of spatial sampling points as well as by the shape of every sampling pixel that generates spectral low-pass filtering. We present a novel approach to overcome the low-pass filtering that is due to the shape of the sampling pixels. The approach combines special algorithms together with spatial masking placed in the intermediate image plane and eventually allows geometrical superresolved imaging without relation to the actual shape of the pixels.

  3. Mask industry quality assessment

    Science.gov (United States)

    Strott, Al; Bassist, Larry

    1994-12-01

    Product quality and timely delivery are two of the most important parameters in determining the success of a mask manufacturing facility. Because of the sensitivity of this data, very little was known about industry performance in these areas until an assessment was authored and presented at the 1993 BACUS Symposium by Larry Regis of Intel Corporation, Neil Paulsen of Intel Corporation, and James A. Reynolds of Reynolds Consulting. This data has been updated and will be published and presented at this year's BACUS Symposium. Contributor identities will again remain protected by utilizing Arthur Andersen & Company to compile the submittals. Participation was consistent with last year's representation of over 75% of the total merchant and captive mask volume in the United States. The data compiled includes shipments, customer return rate, customer return reasons from 1988 through Q2, 1994, performance to schedule, plate survival yield, and throughput time (TPT).

  4. Mask strategy at International SEMATECH

    Science.gov (United States)

    Kimmel, Kurt R.

    2002-08-01

    International SEMATECH (ISMT) is a consortium consisting of 13 leading semiconductor manufacturers from around the globe. Its objective is to develop the infrastructure necessary for its member companies to realize the International Technology Roadmap for Semiconductors (ITRS) through efficiencies of shared development resources and knowledge. The largest area of effort is lithography, recognized as a crucial enabler for microelectronics technology progress. Within the Lithography Division, most of the efforts center on mask-related issues. The development strategy at International SEMATCH will be presented and the interlock of lithography projects clarified. Because of the limited size of the mask production equipment market, the business case is weak for aggressive investment commensurate with the pace of the International Technology Roadmap for Semiconductors. With masks becoming the overwhelming component of lithography cost, new ways of reducing or eliminating mask costs are being explored. Will mask technology survive without a strong business case? Will the mask industry limit the growth of the semiconductor industry? Are advanced masks worth their escalating cost? An analysis of mask cost from the perspective of mask value imparted to the user is presented with examples and generic formulas for the reader to apply independently. A key part to the success for both International SEMATECH and the industry globally will be partnerships on both the local level between mask-maker and mask-user, and the macro level where global collaborations will be necessary to resolve technology development cost challenges.

  5. Mask fabrication process

    Science.gov (United States)

    Cardinale, Gregory F.

    2000-01-01

    A method for fabricating masks and reticles useful for projection lithography systems. An absorber layer is conventionally patterned using a pattern and etch process. Following the step of patterning, the entire surface of the remaining top patterning photoresist layer as well as that portion of an underlying protective photoresist layer where absorber material has been etched away is exposed to UV radiation. The UV-exposed regions of the protective photoresist layer and the top patterning photoresist layer are then removed by solution development, thereby eliminating the need for an oxygen plasma etch and strip and chances for damaging the surface of the substrate or coatings.

  6. X-ray masks

    International Nuclear Information System (INIS)

    Greenwood, J.C.; Satchell, D.W.

    1984-01-01

    In semiconductor manufacture, where X-ray irradiation is used, a thin silicon membrane can be used as an X-ray mask. This membrane has areas on which are patterns to define the regions to be irradiated. These regions are of antireflection material. With the thin, in the order of 3 microns, membranes used, fragility is a problem. Hence a number of ribs of silicon are formed integral with the membrane, and which are relatively thick, 5 to 10 microns. The ribs may be formed by localised deeper boron deposition followed by a selective etch. (author)

  7. Mask alignment system for semiconductor processing

    Science.gov (United States)

    Webb, Aaron P.; Carlson, Charles T.; Weaver, William T.; Grant, Christopher N.

    2017-02-14

    A mask alignment system for providing precise and repeatable alignment between ion implantation masks and workpieces. The system includes a mask frame having a plurality of ion implantation masks loosely connected thereto. The mask frame is provided with a plurality of frame alignment cavities, and each mask is provided with a plurality of mask alignment cavities. The system further includes a platen for holding workpieces. The platen may be provided with a plurality of mask alignment pins and frame alignment pins configured to engage the mask alignment cavities and frame alignment cavities, respectively. The mask frame can be lowered onto the platen, with the frame alignment cavities moving into registration with the frame alignment pins to provide rough alignment between the masks and workpieces. The mask alignment cavities are then moved into registration with the mask alignment pins, thereby shifting each individual mask into precise alignment with a respective workpiece.

  8. Akathisia masked by hypokinesia.

    Science.gov (United States)

    Tuisku, K; Lauerma, H; Holi, M M; Honkonen, T; Rimon, R

    2000-07-01

    Here, we will discuss the concept of subjective akathisia and present a patient case. Our patient was suffering from neuroleptic-induced hypokinesia and akathisia at the same time. The typical motor manifestations of akathisia were masked by hypokinesia, which made the diagnosis difficult. However, the subjective symptoms of akathisia were evident and distressing. Although not observable to bare eye, the pathognomonic pattern of motor activity detected in akathisia was demonstrated by actometric recording. Changing the conventional neuroleptic to an atypical one brought relief to the subjective symptoms of akathisia and hypokinesia, while the motor activity was clearly diminished in actometric recording. Actometric recording may be useful in diagnosing akathisia masked by hypokinesia, but the typical subjective symptoms of akathisia should not be ignored, even when actometry is not available to demonstrate the missing motor component of akathisia. Not only akathisia defined by DSM-IV but also subjective akathisia should be adequately treated to relieve the subjective distress, and to diminish the unfavorable effects on psychotic symptoms, behavior, and drug compliance.

  9. The implementation of Mask-Ed: reflections of academic participants.

    Science.gov (United States)

    Reid-Searl, Kerry; Levett-Jones, Tracy; Cooper, Simon; Happell, Brenda

    2014-09-01

    This paper profiles the findings from a study that explored the perspectives and experiences of nurse educators who implemented a novel simulation approach termed Mask-Ed. The technique involves the educator wearing a silicone mask and or body parts and transforming into a character. The premise of this approach is that the masked educator has domain specific knowledge related to the simulation scenario and can transmit this to learners in a way that is engaging, realistic, spontaneous and humanistic. Nurse educators charged with the responsibility of implementing Mask-Ed in three universities were invited to participate in the study by attending an introductory workshop, implementing the technique and then journaling their experiences, insights and perspectives over a 12 month period. The journal entries were then thematically analysed. Key themes were categorised under the headings of Preparation, Implementation and Impact; Reflexivity and Responsiveness; Student Engagement and Ownership; and Teaching and Learning. Mask-Ed is a simulation approach which allows students to interact with the 'characters' in humanistic ways that promote person-centred care and therapeutic communication. This simulation approach holds previously untapped potential for a range of learning experiences, however, to be effective, adequate resourcing, training, preparation and practice is required. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. The Character Adaptation of Masked Puppet Figures in Ruwatan Ritual

    Directory of Open Access Journals (Sweden)

    Robby Hidajat

    2016-12-01

    Full Text Available One myth that is believed by people living in Duwet village is distress that threatens human beings from when they are born till the day they die. As one way to overcome the distress, people, especially those who are living in Duwet village, hold ritual called as tolak bala. One step in the ritual is self-cleaning oneself from distress or sukerta. In addition to the ritual is a masked puppet as a means of the ritual execution. Thus, this study aims at finding out the functions of the Ruwatan masked puppet. Functional-structural perspective was adopted in the study by implementing observation, interview, and documentation study techniques. Results show that masked puppet has a special function which is to serve as a means of Ruwatan that is specifically to obtain society participation in order to give spiritual support to the process of ritual as a whole tolak bala or distress expulsion process.

  11. SEMATECH EUVL mask program status

    Science.gov (United States)

    Yun, Henry; Goodwin, Frank; Huh, Sungmin; Orvek, Kevin; Cha, Brian; Rastegar, Abbas; Kearney, Patrick

    2009-04-01

    As we approach the 22nm half-pitch (hp) technology node, the industry is rapidly running out of patterning options. Of the several lithography techniques highlighted in the International Technology Roadmap for Semiconductors (ITRS), the leading contender for the 22nm hp insertion is extreme ultraviolet lithography (EUVL). Despite recent advances with EUV resist and improvements in source power, achieving defect free EUV mask blank and enabling the EUV mask infrastructure still remain critical issues. To meet the desired EUV high volume manufacturing (HVM) insertion target date of 2013, these obstacles must be resolved on a timely bases. Many of the EUV mask related challenges remain in the pre-competitive stage and a collaborative industry based consortia, such as SEMATECH can play an important role to enable the EUVL landscape. SEMATECH based in Albany, NY is an international consortium representing several of the largest manufacturers in the semiconductor market. Full members include Intel, Samsung, AMD, IBM, Panasonic, HP, TI, UMC, CNSE (College of Nanoscience and Engineering), and Fuller Road Management. Within the SEMATECH lithography division a major thrust is centered on enabling the EUVL ecosystem from mask development, EUV resist development and addressing EUV manufacturability concerns. An important area of focus for the SEMATECH mask program has been the Mask Blank Development Center (MBDC). At the MBDC key issues in EUV blank development such as defect reduction and inspection capabilities are actively pursued together with research partners, key suppliers and member companies. In addition the mask program continues a successful track record of working with the mask community to manage and fund critical mask tools programs. This paper will highlight recent status of mask projects and longer term strategic direction at the MBDC. It is important that mask technology be ready to support pilot line development HVM by 2013. In several areas progress has been

  12. Effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance

    Science.gov (United States)

    Dietze, Uwe; Dress, Peter; Waehler, Tobias; Singh, Sherjang; Jonckheere, Rik; Baudemprez, Bart

    2011-03-01

    Extreme Ultraviolet Lithography (EUVL) is considered the leading lithography technology choice for semiconductor devices at 16nm HP node and beyond. However, before EUV Lithography can enter into High Volume Manufacturing (HVM) of advanced semiconductor devices, the ability to guarantee mask integrity at point-of-exposure must be established. Highly efficient, damage free mask cleaning plays a critical role during the mask manufacturing cycle and throughout the life of the mask, where the absence of a pellicle to protect the EUV mask increases the risk of contamination during storage, handling and use. In this paper, we will present effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance, which employs an intelligent, holistic approach to maximize Mean Time Between Cleans (MBTC) and extend the useful life span of the reticle. The data presented will demonstrate the protection of the capping and absorber layers, preservation of pattern integrity as well as optical and mechanical properties to avoid unpredictable CD-linewidth and overlay shifts. Experiments were performed on EUV blanks and pattern masks using various process conditions. Conditions showing high particle removal efficiency (PRE) and minimum surface layer impact were then selected for durability studies. Surface layer impact was evaluated over multiple cleaning cycles by means of UV reflectivity metrology XPS analysis and wafer prints. Experimental results were compared to computational models. Mask life time predictions where made using the same computational models. The paper will provide a generic overview of the cleaning sequence which yielded best results, but will also provide recommendations for an efficient in-fab mask maintenance scheme, addressing handling, storage, cleaning and inspection.

  13. Data Shuffling--A New Masking Approach for Numerical Data

    OpenAIRE

    Krishnamurty Muralidhar; Rathindra Sarathy

    2006-01-01

    This study discusses a new procedure for masking confidential numerical data--a procedure called data shuffling--in which the values of the confidential variables are "shuffled" among observations. The shuffled data provides a high level of data utility and minimizes the risk of disclosure. From a practical perspective, data shuffling overcomes reservations about using perturbed or modified confidential data because it retains all the desirable properties of perturbation methods and performs ...

  14. EUV mask manufacturing readiness in the merchant mask industry

    Science.gov (United States)

    Green, Michael; Choi, Yohan; Ham, Young; Kamberian, Henry; Progler, Chris; Tseng, Shih-En; Chiou, Tsann-Bim; Miyazaki, Junji; Lammers, Ad; Chen, Alek

    2017-10-01

    As nodes progress into the 7nm and below regime, extreme ultraviolet lithography (EUVL) becomes critical for all industry participants interested in remaining at the leading edge. One key cost driver for EUV in the supply chain is the reflective EUV mask. As of today, the relatively few end users of EUV consist primarily of integrated device manufactures (IDMs) and foundries that have internal (captive) mask manufacturing capability. At the same time, strong and early participation in EUV by the merchant mask industry should bring value to these chip makers, aiding the wide-scale adoption of EUV in the future. For this, merchants need access to high quality, representative test vehicles to develop and validate their own processes. This business circumstance provides the motivation for merchants to form Joint Development Partnerships (JDPs) with IDMs, foundries, Original Equipment Manufacturers (OEMs) and other members of the EUV supplier ecosystem that leverage complementary strengths. In this paper, we will show how, through a collaborative supplier JDP model between a merchant and OEM, a novel, test chip driven strategy is applied to guide and validate mask level process development. We demonstrate how an EUV test vehicle (TV) is generated for mask process characterization in advance of receiving chip maker-specific designs. We utilize the TV to carry out mask process "stress testing" to define process boundary conditions which can be used to create Mask Rule Check (MRC) rules as well as serve as baseline conditions for future process improvement. We utilize Advanced Mask Characterization (AMC) techniques to understand process capability on designs of varying complexity that include EUV OPC models with and without sub-resolution assist features (SRAFs). Through these collaborations, we demonstrate ways to develop EUV processes and reduce implementation risks for eventual mass production. By reducing these risks, we hope to expand access to EUV mask capability for

  15. Masks for extreme ultraviolet lithography

    International Nuclear Information System (INIS)

    Cardinale, G; Goldsmith, J; Kearney, P A; Larson, C; Moore, C E; Prisbrey, S; Tong, W; Vernon, S P; Weber, F; Yan, P-Y.

    1998-01-01

    In extreme ultraviolet lithography (EUVL), the technology specific requirements on the mask are a direct consequence of the utilization of radiation in the spectral region between 10 and 15 nm. At these wavelengths, all condensed materials are highly absorbing and efficient radiation transport mandates the use of all-reflective optical systems. Reflectivity is achieved with resonant, wavelength-matched multilayer (ML) coatings on all of the optical surfaces - including the mask. The EUV mask has a unique architecture - it consists of a substrate with a highly reflective ML coating (the mask blank) that is subsequently over-coated with a patterned absorber layer (the mask). Particulate contamination on the EUVL mask surface, errors in absorber definition and defects in the ML coating all have the potential to print in the lithographic process. While highly developed technologies exist for repair of the absorber layer, no viable strategy for the repair of ML coating defects has been identified. In this paper the state-of-the-art in ML deposition technology, optical inspection of EUVL mask blank defects and candidate absorber patterning approaches are reviewed

  16. Antigenic determinants and functional domains in core antigen and e antigen from hepatitis B virus

    International Nuclear Information System (INIS)

    Salfeld, J.; Pfaff, E.; Noah, M.; Schaller, H.

    1989-01-01

    The precore/core gene of hepatitis B virus directs the synthesis of two polypeptides, the 21-kilodalton subunit (p21c) forming the viral nucleocapsid (serologically defined as core antigen [HBcAg]) and a secreted processed protein (p17e, serologically defined as HBe antigen [HBeAg]). Although most of their primary amino acid sequences are identical, HBcAg and HBeAg display different antigenic properties that are widely used in hepatitis B virus diagnosis. To locate and to characterize the corresponding determinants, segments of the core gene were expressed in Escherichia coli and probed with a panel of polyclonal or monoclonal antibodies in radioimmunoassays or enzyme-linked immunosorbent assays, Western blots, and competition assays. Three distinct major determinants were characterized. It is postulated that HBcAg and HBeAg share common basic three-dimensional structure exposing the common linear determinant HBe1 but that they differ in the presentation of two conformational determinants that are either introduced (HBc) or masked (HBe2) in the assembled core. The simultaneous presentation of HBe1 and HBc, two distinctly different antigenic determinants with overlapping amino acid sequences, is interpreted to indicate the presence of slightly differently folded, stable conformational states of p21c in the hepatitis virus nucleocapsid

  17. Mechanical alignment of substrates to a mask

    Science.gov (United States)

    Webb, Aaron P.; Carlson, Charles T.; Honan, Michael; Amato, Luigi G.; Grant, Christopher Neil; Strassner, James D.

    2016-11-08

    A plurality of masks is attached to the underside of a mask frame. This attachment is made such that each mask can independently move relative to the mask frame in three directions. This relative movement allows each mask to adjust its position to align with respective alignment pins disposed on a working surface. In one embodiment, each mask is attached to the mask frame using fasteners, where the fasteners have a shaft with a diameter smaller than the diameter of the mounting hole disposed on the mask. A bias element may be used to allow relative movement between the mask and the mask frame in the vertical direction. Each mask may also have kinematic features to mate with the respective alignment pins on the working surface.

  18. Immunity to tumour antigens.

    Science.gov (United States)

    Li, Geng; Ali, Selman A; McArdle, Stephanie E B; Mian, Shahid; Ahmad, Murrium; Miles, Amanda; Rees, Robert C

    2005-01-01

    During the last decade, a large number of human tumour antigens have been identified. These antigens are classified as tumour-specific shared antigens, tissue-specific differentiation antigens, overexpressed antigens, tumour antigens resulting from mutations, viral antigens and fusion proteins. Antigens recognised by effectors of immune system are potential targets for antigen-specific cancer immunotherapy. However, most tumour antigens are self-proteins and are generally of low immunogenicity and the immune response elicited towards these tumour antigens is not always effective. Strategies to induce and enhance the tumour antigen-specific response are needed. This review will summarise the approaches to discovery of tumour antigens, the current status of tumour antigens, and their potential application to cancer treatment.

  19. Influence of mask type and mask position on the effectiveness of bag-mask ventilation in a neonatal manikin.

    Science.gov (United States)

    Deindl, Philipp; O'Reilly, Megan; Zoller, Katharina; Berger, Angelika; Pollak, Arnold; Schwindt, Jens; Schmölzer, Georg M

    2014-01-01

    Anatomical face mask with an air cushion rim might be placed accidentally in a false orientation on the newborn's face or filled with various amounts of air during neonatal resuscitation. Both false orientation as well as variable filling may reduce a tight seal and therefore hamper effective positive pressure ventilation (PPV). We aimed to measure the influence of mask type and mask position on the effectiveness of PPV. Twenty neonatal staff members delivered PPV to a modified, leak-free manikin. Resuscitation parameters were recorded using a self-inflatable bag PPV with an Intersurgical anatomical air cushion rim face mask (IS) and a size 0/1 Laerdal round face mask. Three different positions of the IS were tested: correct position, 90° and 180° rotation in reference to the midline of the face. IS masks in each correct position on the face but with different inflation of the air cushion (empty, 10, 20 and 30 mL). Mask leak was similar with mask rotation to either 90° or 180° but significantly increased from 27 (13-73) % with an adequate filled IS mask compared to 52 (16-83) % with an emptied air cushion rim. Anatomical-shaped face mask had similar mask leaks compared to round face mask. A wrongly positioned anatomical-shaped mask does not influence mask leak. Mask leak significantly increased once the air cushion rim was empty, which may cause failure in mask PPV.

  20. Image differencing using masked CCD

    International Nuclear Information System (INIS)

    Rushbrooke, J.G.; Ansorge, R.E.; Webber, C.J. St. J.

    1987-01-01

    A charge coupled device has some of its ''pixels'' masked by a material which is opaque to the radiation to which the device is to be exposed, each masked region being employed as a storage zone into which the charge pattern from the unmasked pixels can be transferred to enable a subsequent charge pattern to be established on further exposure of the unmasked pixels. The components of the resulting video signal corresponding to the respective charge patterns read-out from the CCD are subtracted to produce a video signal corresponding to the difference between the two images which formed the respective charge patterns. Alternate rows of pixels may be masked, or chequer-board pattern masking may be employed. In an X-ray imaging system the CCD is coupled to image intensifying and converting means. (author)

  1. Vibrotactile masking through the body.

    Science.gov (United States)

    D'Amour, Sarah; Harris, Laurence R

    2014-09-01

    Touches on one hand or forearm can affect tactile sensitivity at contralateral locations on the opposite side of the body. These interactions suggest an intimate connection between the two sides of the body. Here, we explore the effect of masking not across the body but through the body by measuring the effect of a masking stimulus on the back on the tactile sensitivity of the corresponding point on the front. Tactile sensitivity was measured on each side of the stomach, while vibrotactile masking stimulation was applied to one side of the front and to points on the back including the point directly behind the test point on the front. Results were compared to sensitivity, while vibrotactile stimulation was applied to a control site on the shoulder. A reduction in sensitivity of about .8 dB was found that required the masking stimulus to be within about 2 cm of the corresponding point on the back.

  2. Hybrid mask for deep etching

    KAUST Repository

    Ghoneim, Mohamed T.

    2017-01-01

    Deep reactive ion etching is essential for creating high aspect ratio micro-structures for microelectromechanical systems, sensors and actuators, and emerging flexible electronics. A novel hybrid dual soft/hard mask bilayer may be deposited during

  3. Rapid iconic erasure without masking.

    Science.gov (United States)

    Tijus, Charles Albert; Reeves, Adam

    2004-01-01

    We report on the erasure of the iconic memory of an array of 12 black letters flashed on a continuously- present white field. Erasure is accomplished by replacing the 16 ms letter array (frame 1) with a blank white frame for 16 ms (frame 2). The letter array returns in frame 3, with from one to six letters missing. Report of the missing letters is accurate without the blank white frame but is impoverished with it, as if interposing the blank erases the icon. Erasure occurs without any obvious luminance masking, 'mud splashes', pattern masking (backward, forward, or metacontrast), lateral masking, or masking by object substitution. Erasure is greatly decreased if the blank is presented one frame earlier or later. We speculate that erasure is due to a rapid reset of the icon produced by an informational mis-match.

  4. A masking index for quantifying hidden glitches

    OpenAIRE

    Berti-Equille, Laure; Loh, J. M.; Dasu, T.

    2015-01-01

    Data glitches are errors in a dataset. They are complex entities that often span multiple attributes and records. When they co-occur in data, the presence of one type of glitch can hinder the detection of another type of glitch. This phenomenon is called masking. In this paper, we define two important types of masking and propose a novel, statistically rigorous indicator called masking index for quantifying the hidden glitches. We outline four cases of masking: outliers masked by missing valu...

  5. Contralateral tactile masking between forearms.

    Science.gov (United States)

    D'Amour, Sarah; Harris, Laurence R

    2014-03-01

    Masking effects have been demonstrated in which tactile sensitivity is affected when one touch is close to another on the body surface. Such effects are likely a result of local lateral inhibitory circuits that sharpen the spatial tuning of a given tactile receptor. Mutually inhibitory pathways have also been demonstrated between cortical tactile maps of the two halves of the body. Occasional reports have indicated that touches on one hand or forearm can affect tactile sensitivity at contralateral locations. Here, we measure the spatial tuning and effect of posture on this contralateral masking effect. Tactile sensitivity was measured on one forearm, while vibrotactile masking stimulation was applied to the opposite arm. Results were compared to sensitivity while vibrotactile stimulation was applied to a control site on the right shoulder. Sensitivity on the forearm was reduced by over 3 dB when the arms were touching and by 0.52 dB when they were held parallel. The masking effect depended on the position of the masking stimulus. Its effectiveness fell off by 1 STD when the stimulus was 29 % of arm length from the corresponding contralateral point. This long-range inhibitory effect in the tactile system suggests a surprisingly intimate relationship between the two sides of the body.

  6. Self-Rescue Mask Training

    CERN Multimedia

    2013-01-01

    Nine new self-rescue mask instructors have been trained since early 2013, which provides CERN with a total of 26 self-rescue mask instructors to date. This will allow us to meet the increasing training needs caused by the Long Shut Down LS1.   The self-rescue mask instructors have trained 1650 persons in 2012 and about 500 persons since the beginning of the year on how to wear the masks properly. We thank all the instructors and all the persons that made this training possible. Please remember that the self-rescue masks training sessions are scheduled as follows: Basic course: Tuesday and Thursday mornings (2 sessions – 8.30 AM and 10.30 AM), duration:  1.30 hour, in French and English – registration via CERN online training catalogue – Course code 077Y00. Refresher training : Monday mornings (2 sessions – 8.30 AM and 10.30 AM), duration: 1.30 hour , in French and English – registration via CERN online training catalogue &...

  7. Carcinoma-associated antigens

    International Nuclear Information System (INIS)

    Bartorelli, A.; Accinni, R.

    1981-01-01

    This invention relates to novel antigens associated with breast carcinoma, anti-sera specific to said antigens, 125 I-labeled forms of said antigens and methods of detecting said antigens in serum or plasma. The invention also relates to a diagnostic kit containing standardised antigens or antisera or marked forms thereof for the detection of said antigens in human blood, serum or plasma. (author)

  8. 1995 mask industry quality assessment

    Science.gov (United States)

    Bishop, Chris; Strott, Al

    1995-12-01

    The third annual mask industry assessment will again survey various industry companies for key performance measurements in the areas of quality and delivery. This year's assessment is enhanced to include the area of safety and further breakdown of the data into 5-inch vs. 6- inch. The data compiled includes shipments, customer return rate, customer return reason, performance to schedule, plate survival yield, and throughput time (TPT) from 1988 through Q2, 1995. Contributor identities remain protected by utilizing Arthur Andersen & Company to ensure participant confidentiality. Participation in the past included representation of over 75% of the total merchant and captive mask volume in the United States. This year's assessment is expected to result in expanded participation by again inviting all mask suppliers domestically to participate as well as an impact from inviting international suppliers to participate.

  9. Electrostatic mask for active targets

    International Nuclear Information System (INIS)

    Pancin, J; Gangnant, P; Libin, J-F; Raabe, R; Roger, T; Roussel-Chomaz, P; Gibelin, J; Goth, M

    2012-01-01

    Active gas targets have been used in nuclear physics since 30 years. They are promising systems in view of the new exotic beams soon available at facilities like SPIRAL2 or FAIR, but the system can still be improved. One of the main limitation is the dynamic range in energy deposition. The energy deposited per unit length can be 3 decades higher for the beam than for the light reaction products and the risk to saturate the electronics or that the detector spark are not negligible. A simple solution using a wire plane to mask partially the beam is presented here. Some simulation has been realized and some experimental results are shown confirming the feasibility of this wire tunable mask. The mask can be used from full transparency to full opacity without degrading neither the drift electric field of the chamber nor the performances of detection of the beam or the light products.

  10. Self-masking subtraction tomosynthesis

    International Nuclear Information System (INIS)

    Chakraborty, D.P.; Yester, M.V.; Barnes, G.T.; Lakshminarayanan, A.V.

    1984-01-01

    The authors tested the image quality and dose savings of self-masking subtraction tomosynthesis (SST), which combines digital tomosynthesis with subtraction of a blurred self-mask. High-quality images of the inner ear of a head phantom were obtained at moderate dose savings. Although they were taken with linear motion, they did not exhibit the streaking due to off-fulcrum objects that is characteristic of conventional linear tomography. SST could reduce patient dose by a factor of at least 12 in examinations of the inner ear, and the mechanical aspects can be implemented with moderate modifications of existing instrumentation

  11. Classification and printability of EUV mask defects from SEM images

    Science.gov (United States)

    Cho, Wonil; Price, Daniel; Morgan, Paul A.; Rost, Daniel; Satake, Masaki; Tolani, Vikram L.

    2017-10-01

    Classification and Printability of EUV Mask Defects from SEM images EUV lithography is starting to show more promise for patterning some critical layers at 5nm technology node and beyond. However, there still are many key technical obstacles to overcome before bringing EUV Lithography into high volume manufacturing (HVM). One of the greatest obstacles is manufacturing defect-free masks. For pattern defect inspections in the mask-shop, cutting-edge 193nm optical inspection tools have been used so far due to lacking any e-beam mask inspection (EBMI) or EUV actinic pattern inspection (API) tools. The main issue with current 193nm inspection tools is the limited resolution for mask dimensions targeted for EUV patterning. The theoretical resolution limit for 193nm mask inspection tools is about 60nm HP on masks, which means that main feature sizes on EUV masks will be well beyond the practical resolution of 193nm inspection tools. Nevertheless, 193nm inspection tools with various illumination conditions that maximize defect sensitivity and/or main-pattern modulation are being explored for initial EUV defect detection. Due to the generally low signal-to-noise in the 193nm inspection imaging at EUV patterning dimensions, these inspections often result in hundreds and thousands of defects which then need to be accurately reviewed and dispositioned. Manually reviewing each defect is difficult due to poor resolution. In addition, the lack of a reliable aerial dispositioning system makes it very challenging to disposition for printability. In this paper, we present the use of SEM images of EUV masks for higher resolution review and disposition of defects. In this approach, most of the defects detected by the 193nm inspection tools are first imaged on a mask SEM tool. These images together with the corresponding post-OPC design clips are provided to KLA-Tencor's Reticle Decision Center (RDC) platform which provides ADC (Automated Defect Classification) and S2A (SEM

  12. Masked hypertension in diabetes mellitus

    DEFF Research Database (Denmark)

    Franklin, Stanley S; Thijs, Lutgarde; Li, Yan

    2013-01-01

    Although distinguishing features of masked hypertension in diabetics are well known, the significance of antihypertensive treatment on clinical practice decisions has not been fully explored. We analyzed 9691 subjects from the population-based 11-country International Database on Ambulatory Blood...

  13. Gamma camera with reflectivity mask

    International Nuclear Information System (INIS)

    Stout, K.J.

    1980-01-01

    In accordance with the present invention there is provided a radiographic camera comprising: a scintillator; a plurality of photodectors positioned to face said scintillator; a plurality of masked regions formed upon a face of said scintillator opposite said photdetectors and positioned coaxially with respective ones of said photodetectors for decreasing the amount of internal reflection of optical photons generated within said scintillator. (auth)

  14. "The Mask Who Wasn't There": Visual Masking Effect with the Perceptual Absence of the Mask

    Science.gov (United States)

    Rey, Amandine Eve; Riou, Benoit; Muller, Dominique; Dabic, Stéphanie; Versace, Rémy

    2015-01-01

    Does a visual mask need to be perceptually present to disrupt processing? In the present research, we proposed to explore the link between perceptual and memory mechanisms by demonstrating that a typical sensory phenomenon (visual masking) can be replicated at a memory level. Experiment 1 highlighted an interference effect of a visual mask on the…

  15. Gestalt grouping and common onset masking.

    Science.gov (United States)

    Kahan, Todd A; Mathis, Katherine M

    2002-11-01

    A four-dot mask that surrounds and is presented simultaneously with a briefly presented target will reduce a person's ability to identity that target if the mask persists beyond target offset and attention is divided (Enns & Di Lollo, 1997, 2000). This masking effect, referred to as common onset masking, reflects reentrant processing in the visual system and can best be explained with a theory of object substitution (Di Lollo, Enns, & Rensink, 2000). In the present experiments, we investigated whether Gestalt grouping variables would influence the strength of common onset masking. The results indicated that (1) masking was impervious to grouping by form, similarity of color, position, luminance polarity, and common region and (2) masking increased with the number of elements in the masking display.

  16. Selective spatial attention modulates bottom-up informational masking of speech.

    Science.gov (United States)

    Carlile, Simon; Corkhill, Caitlin

    2015-03-02

    To hear out a conversation against other talkers listeners overcome energetic and informational masking. Largely attributed to top-down processes, information masking has also been demonstrated using unintelligible speech and amplitude-modulated maskers suggesting bottom-up processes. We examined the role of speech-like amplitude modulations in information masking using a spatial masking release paradigm. Separating a target talker from two masker talkers produced a 20 dB improvement in speech reception threshold; 40% of which was attributed to a release from informational masking. When across frequency temporal modulations in the masker talkers are decorrelated the speech is unintelligible, although the within frequency modulation characteristics remains identical. Used as a masker as above, the information masking accounted for 37% of the spatial unmasking seen with this masker. This unintelligible and highly differentiable masker is unlikely to involve top-down processes. These data provides strong evidence of bottom-up masking involving speech-like, within-frequency modulations and that this, presumably low level process, can be modulated by selective spatial attention.

  17. Selective phase masking to reduce material saturation in holographic data storage systems

    Science.gov (United States)

    Phillips, Seth; Fair, Ivan

    2014-09-01

    Emerging networks and applications require enormous data storage. Holographic techniques promise high-capacity storage, given resolution of a few remaining technical issues. In this paper, we propose a technique to overcome one such issue: mitigation of large magnitude peaks in the stored image that cause material saturation resulting in readout errors. We consider the use of ternary data symbols, with modulation in amplitude and phase, and use a phase mask during the encoding stage to reduce the probability of large peaks arising in the stored Fourier domain image. An appropriate mask is selected from a predefined set of pseudo-random masks by computing the Fourier transform of the raw data array as well as the data array multiplied by each mask. The data array or masked array with the lowest Fourier domain peak values is recorded. On readout, the recorded array is multiplied by the mask used during recording to recover the original data array. Simulations are presented that demonstrate the benefit of this approach, and provide insight into the appropriate number of phase masks to use in high capacity holographic data storage systems.

  18. Bitter taste masking of enzyme-treated soy protein in water and bread.

    Science.gov (United States)

    Bertelsen, Anne S; Laursen, Anne; Knudsen, Tine A; Møller, Stine; Kidmose, Ulla

    2018-08-01

    Bioactive protein hydrolysates are often very bitter. To overcome this challenge, xylitol, sucrose, α-cyclodextrin, maltodextrin and combinations of these were tested systematically as bitter-masking agents of an enzyme-treated soy protein in an aqueous model and in a bread model. Sensory descriptive analysis was used to reveal the bitter-masking effect of the taste-masking blends on the enzyme-treated soy protein. In water, xylitol, sucrose and maltodextrin reduced bitterness significantly, whereas α-cyclodextrin did not. No significant difference was observed in bitterness reduction between xylitol and sucrose. Both reduced bitterness significantly more than maltodextrin. No interactions between the taste-masking agents affecting bitterness reduction were found. Clearer bitter-masking effects were seen in the aqueous model compared with the bread model. The bitter-masking effects of α-cyclodextrin and maltodextrin were similar between water and bread. The effect of xylitol and sucrose on bitterness suppression varied between the systems. In water, bitterness was negatively correlated with sweetness. In bread, bitterness was negatively correlated with freshness, and maltodextrin significantly reduced bitterness of the enzyme-treated soy protein and increased freshness. Bitter-masking effects were generally more discernible in the aqueous model compared with the bread model. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  19. 21 CFR 868.5590 - Scavenging mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Scavenging mask. 868.5590 Section 868.5590 Food... DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5590 Scavenging mask. (a) Identification. A scavenging mask is a device positioned over a patient's nose to deliver anesthetic or analgesic gases to the...

  20. Ergonomic evaluation of pilot oxygen mask designs

    NARCIS (Netherlands)

    Lee, W.; Yang, Xiaopeng; Jung, Daehan; Park, Seikwon; Kim, Heeeun; You, Heecheon

    2018-01-01

    A revised pilot oxygen mask design was developed for better fit to the Korean Air Force pilots’ faces. The present study compared an existing pilot oxygen mask and a prototype of the revised mask design with 88 Korean Air Force pilots in terms of subjective discomfort, facial contact pressure,

  1. 21 CFR 868.5580 - Oxygen mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxygen mask. 868.5580 Section 868.5580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5580 Oxygen mask. (a) Identification. An oxygen mask is a device...

  2. 21 CFR 868.5570 - Nonrebreathing mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonrebreathing mask. 868.5570 Section 868.5570...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5570 Nonrebreathing mask. (a) Identification. A nonrebreathing mask is a device fitting over a patient's face to administer oxygen. It utilizes...

  3. 21 CFR 868.5600 - Venturi mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Venturi mask. 868.5600 Section 868.5600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5600 Venturi mask. (a) Identification. A venturi mask is a...

  4. Rates of initial acceptance of PAP masks and outcomes of mask switching.

    Science.gov (United States)

    Bachour, Adel; Vitikainen, Pirjo; Maasilta, Paula

    2016-05-01

    Recently, we noticed a considerable development in alleviating problems related to positive airway pressure (PAP) masks. In this study, we report on the initial PAP mask acceptance rates and the effects of mask switching on mask-related symptoms. We prospectively collected all cases of mask switching in our sleep unit for a period of 14 months. At the time of the study, we used ResMed™ CPAP devices and masks. Mask switching was defined as replacing a mask used for at least 1 day with another type of mask. Changing to a different size but keeping the same type of mask did not count as mask switching. Switching outcomes were considered failed if the initial problem persisted or reappeared during the year that followed switching. Our patient pool was 2768. We recorded 343 cases of mask switching among 267 patients. Of the 566 patients who began new PAP therapy, 108 (39 women) had switched masks, yielding an initial mask acceptance rate of 81 %. The reason for switching was poor-fit/uncomfortable mask in 39 %, leak-related in 30 %, outdated model in 25 %, and nasal stuffiness in 6 % of cases; mask switching resolved these problems in 61 %. Mask switching occurred significantly (p = 0.037) more often in women and in new PAP users. The odds ratio for abandoning PAP therapy within 1 year after mask switching was 7.2 times higher (interval 4.7-11.1) than not switching masks. The initial PAP mask acceptance rate was high. Patients who switched their masks are at greater risk for abandoning PAP therapy.

  5. Masking and Partial Masking in Listeners with a High-Frequency Hearing Loss

    NARCIS (Netherlands)

    Smits, J.T.S.; Duifhuis, H.

    1982-01-01

    3 listeners with sensorineural hearing loss ranging from moderate to moderate-severe starting at frequencies higher than 1 kHz participated in two masking experiments and a partial masking experiment. In the first masking experiment, fM = 1 kHz and LM = 50 dB SPL, higher than normal masked

  6. Extracting messages masked by chaos

    International Nuclear Information System (INIS)

    Perez, G.; Cerdeira, H.A.

    1995-01-01

    We show how to extract messages that are masked by a chaotic signal in a system of two Lorenz oscillators. This mask removal is done for two different modes of transmission, a digital one where a parameter of the sender is switched between two values, and an analog mode, where a small amplitude message is added to the carrier signal. We achieve this without using a second Lorenz oscillator as receiver, and without doing a full reconstruction of the dynamics. This method is robust with respect to transformations that impede the unmasking using a Lorenz receiver, and is not affected by the broad-band noise that is inherent to the synchronization process. We also discuss the limitations of this way of extraction for messages in high frequency bands. (author). 12 refs, 4 figs

  7. Rapid mask prototyping for microfluidics.

    Science.gov (United States)

    Maisonneuve, B G C; Honegger, T; Cordeiro, J; Lecarme, O; Thiry, T; Fuard, D; Berton, K; Picard, E; Zelsmann, M; Peyrade, D

    2016-03-01

    With the rise of microfluidics for the past decade, there has come an ever more pressing need for a low-cost and rapid prototyping technology, especially for research and education purposes. In this article, we report a rapid prototyping process of chromed masks for various microfluidic applications. The process takes place out of a clean room, uses a commercially available video-projector, and can be completed in less than half an hour. We quantify the ranges of fields of view and of resolutions accessible through this video-projection system and report the fabrication of critical microfluidic components (junctions, straight channels, and curved channels). To exemplify the process, three common devices are produced using this method: a droplet generation device, a gradient generation device, and a neuro-engineering oriented device. The neuro-engineering oriented device is a compartmentalized microfluidic chip, and therefore, required the production and the precise alignment of two different masks.

  8. Sinusoidal masks for single channel speech separation

    DEFF Research Database (Denmark)

    Mowlaee, Pejman; Christensen, Mads Græsbøll; Jensen, Søren Holdt

    2010-01-01

    In this paper we present a new approach for binary and soft masks used in single-channel speech separation. We present a novel approach called the sinusoidal mask (binary mask and Wiener filter) in a sinusoidal space. Theoretical analysis is presented for the proposed method, and we show...... that the proposed method is able to minimize the target speech distortion while suppressing the crosstalk to a predetermined threshold. It is observed that compared to the STFTbased masks, the proposed sinusoidal masks improve the separation performance in terms of objective measures (SSNR and PESQ) and are mostly...

  9. Shadows alter facial expressions of Noh masks.

    Directory of Open Access Journals (Sweden)

    Nobuyuki Kawai

    Full Text Available BACKGROUND: A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers' recognition of the emotional expressions. METHODOLOGY/PRINCIPAL FINDINGS: In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. CONCLUSIONS/SIGNIFICANCE: Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa's smile. They also agree with the aesthetic principle of Japanese traditional art "yugen (profound grace and subtlety", which highly appreciates subtle emotional expressions in the darkness.

  10. PMJ panel discussion overview on mask complexities, cost, and cycle time in 32-nm system LSI generation: conflict or concurrent?

    Science.gov (United States)

    Hosono, Kunihiro; Kato, Kokoro

    2008-10-01

    This is a report on a panel discussion organized in Photomask Japan 2008, where the challenges about "Mask Complexities, Cost, and Cycle Time in 32-nm System LSI Generation" were addressed to have a look over the possible solutions from the standpoints of chipmaker, commercial mask shop, DA tool vendor and equipments makers. The wrap-up is as follows: Mask complexities justify the mask cost, while the acceptable increase rate of 32nm-mask cost significantly differs between mask suppliers or users side. The efficiency progress by new tools or DFM has driven their cycle-time reductions. Mask complexities and cost will be crucial issues prior to cycle time, and there seems to be linear correlation between them. Controlling complexity and cycle time requires developing a mix of advanced technologies, and especially for cost reduction, shot prices in writers and processing rates in inspection tools have been improved remarkably by tool makers. In addition, activities of consortium in Japan (Mask D2I) are expected to enhance the total optimization of mask design, writing and inspection. The cycle-time reduction potentially drives the lowering of mask cost, and, on the other, the pattern complexities and tighter mask specifications get in the way to 32nm generation as well as the nano-economics and market challenges. There are still many difficult problems in mask manufacturing now, and we are sure to go ahead to overcome a 32nm hurdle with the advances of technologies and collaborations by not only technologies but also finance.

  11. Irresistable: Service Masks, Goldwater-Nichols, and Overcoming Service Barriers to JFACC

    Science.gov (United States)

    2016-06-10

    Air Forces IFR In Flight Refueling JCS Joint Chiefs of Staff JFACC Joint Force Air Component Commander JFC Joint Force Commander LOC Lines of...culture, diplomacy, and beyond.7 The focus is on the personalities that build and develop the technology and thus their impact on history. This broad...embarked Air Group 5 contained propeller and first-generation jets. In the days before in- flight-refueling ( IFR ), these aircraft could only manage a

  12. Brightness masking is modulated by disparity structure.

    Science.gov (United States)

    Pelekanos, Vassilis; Ban, Hiroshi; Welchman, Andrew E

    2015-05-01

    The luminance contrast at the borders of a surface strongly influences surface's apparent brightness, as demonstrated by a number of classic visual illusions. Such phenomena are compatible with a propagation mechanism believed to spread contrast information from borders to the interior. This process is disrupted by masking, where the perceived brightness of a target is reduced by the brief presentation of a mask (Paradiso & Nakayama, 1991), but the exact visual stage that this happens remains unclear. In the present study, we examined whether brightness masking occurs at a monocular-, or a binocular-level of the visual hierarchy. We used backward masking, whereby a briefly presented target stimulus is disrupted by a mask coming soon afterwards, to show that brightness masking is affected by binocular stages of the visual processing. We manipulated the 3-D configurations (slant direction) of the target and mask and measured the differential disruption that masking causes on brightness estimation. We found that the masking effect was weaker when stimuli had a different slant. We suggest that brightness masking is partly mediated by mid-level neuronal mechanisms, at a stage where binocular disparity edge structure has been extracted. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Exosomes derived from tumor cells genetically modified to express Mycobacterium tuberculosis antigen: a novel vaccine for cancer therapy.

    Science.gov (United States)

    Koyama, Yoshiyuki; Ito, Tomoko; Hasegawa, Aya; Eriguchi, Masazumi; Inaba, Toshio; Ushigusa, Takahiro; Sugiura, Kikuya

    2016-11-01

    To examine the potential of exosomes derived from the tumor cells, which had been genetically modified to express a Mycobacterium tuberculosis antigen, as a cancer vaccine aimed at overcoming the weak immunogenicity of tumor antigens. We transfected B16 melanoma cells with a plasmid encoding the M. tuberculosis antigen, early secretory antigenic target-6 (ESAT-6). The secreted exosomes bearing both tumor-associated antigens and the pathogenic antigen (or their epitopes) were collected. When the exosomes were injected into foot pads of mice, they significantly (p exosomes significantly suppressed (p exosomes derived from the non-transfected B16 cells showed no effect on tumor growth, although both exosomes should have similar tumor antigens. Exosomes bearing both tumor antigens and the M. tuberculosis antigen (or their epitopes) have a high potential as a candidate for cancer vaccine to overcome the immune escape by tumor cells.

  14. Harnessing Dendritic Cells for Tumor Antigen Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Nierkens, Stefan [Department of Tumor Immunology, Nijmegen Centre for Molecular Life Sciences, Radboud University Nijmegen Medical Centre, Geert Grooteplein 28, Nijmegen 6525 GA (Netherlands); Janssen, Edith M., E-mail: edith.janssen@cchmc.org [Division of Molecular Immunology, Cincinnati Children' s Hospital Research Foundation, University of Cincinnati College of Medicine, 3333 Burnet Avenue, Cincinnati, OH 45229 (United States)

    2011-04-26

    Dendritic cells (DC) are professional antigen presenting cells that are crucial for the induction of anti-tumor T cell responses. As a consequence, research has focused on the harnessing of DCs for therapeutic interventions. Although current strategies employing ex vivo-generated and tumor-antigen loaded DCs have been proven feasible, there are still many obstacles to overcome in order to improve clinical trial successes and offset the cost and complexity of customized cell therapy. This review focuses on one of these obstacles and a pivotal step for the priming of tumor-specific CD8{sup +} and CD4{sup +} T cells; the in vitro loading of DCs with tumor antigens.

  15. Protamine-based nanoparticles as new antigen delivery systems.

    Science.gov (United States)

    González-Aramundiz, José Vicente; Peleteiro Olmedo, Mercedes; González-Fernández, África; Alonso Fernández, María José; Csaba, Noemi Stefánia

    2015-11-01

    The use of biodegradable nanoparticles as antigen delivery vehicles is an attractive approach to overcome the problems associated with the use of Alum-based classical adjuvants. Herein we report, the design and development of protamine-based nanoparticles as novel antigen delivery systems, using recombinant hepatitis B surface antigen as a model viral antigen. The nanoparticles, composed of protamine and a polysaccharide (hyaluronic acid or alginate), were obtained using a mild ionic cross-linking technique. The size and surface charge of the nanoparticles could be modulated by adjusting the ratio of the components. Prototypes with optimal physicochemical characteristics and satisfactory colloidal stability were selected for the assessment of their antigen loading capacity, antigen stability during storage and in vitro and in vivo proof-of-concept studies. In vitro studies showed that antigen-loaded nanoparticles induced the secretion of cytokines by macrophages more efficiently than the antigen in solution, thus indicating a potential adjuvant effect of the nanoparticles. Finally, in vivo studies showed the capacity of these systems to trigger efficient immune responses against the hepatitis B antigen following intramuscular administration, suggesting the potential interest of protamine-polysaccharide nanoparticles as antigen delivery systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. A Masked Photocathode in a Photoinjector

    OpenAIRE

    Qiang, Ji

    2011-01-01

    In this paper, we propose a masked photocathode inside a photoinjector for generating high brightness electron beam. Instead of mounting the photocathode onto an electrode, an electrode with small hole is used as a mask to shield the photocathode from the accelerating vacuum chamber. Using such a masked photocathode will make the replacement of photocathode material easy by rotating the photocathode behind the electrode into the hole. Furthermore, this helps reduce the dark current or seconda...

  17. Predicting masking release of lateralized speech

    DEFF Research Database (Denmark)

    Chabot-Leclerc, Alexandre; MacDonald, Ewen; Dau, Torsten

    2016-01-01

    . The largest masking release (MR) was observed when all maskers were on the opposite side of the target. The data in the conditions containing only energetic masking and modulation masking could be accounted for using a binaural extension of the speech-based envelope power spectrum model [sEPSM; Jørgensen et...... al., 2013, J. Acoust. Soc. Am. 130], which uses a short-term equalization-cancellation process to model binaural unmasking. In the conditions where informational masking (IM) was involved, the predicted SRTs were lower than the measured values because the model is blind to confusions experienced...

  18. Set Size and Mask Duration Do Not Interact in Object-Substitution Masking

    Science.gov (United States)

    Argyropoulos, Ioannis; Gellatly, Angus; Pilling, Michael; Carter, Wakefield

    2013-01-01

    Object-substitution masking (OSM) occurs when a mask, such as four dots that surround a brief target item, onsets simultaneously with the target and offsets a short time after the target, rather than simultaneously with it. OSM is a reduction in accuracy of reporting the target with the temporally trailing mask, compared with the simultaneously…

  19. Assessment of molecular contamination in mask pod

    Science.gov (United States)

    Foray, Jean Marie; Dejaune, Patrice; Sergent, Pierre; Gough, Stuart; Cheung, D.; Davenet, Magali; Favre, Arnaud; Rude, C.; Trautmann, T.; Tissier, Michel; Fontaine, H.; Veillerot, M.; Avary, K.; Hollein, I.; Lerit, R.

    2008-04-01

    Context/ study Motivation: Contamination and especially Airbone Molecular Contamination (AMC) is a critical issue for mask material flow with a severe and fairly unpredictable risk of induced contamination and damages especially for 193 nm lithography. It is therefore essential to measure, to understand and then try to reduce AMC in mask environment. Mask material flow was studied in a global approach by a pool of European partners, especially within the frame of European MEDEA+ project, so called "MUSCLE". This paper deals with results and assessment of mask pod environment in term of molecular contamination in a first step, then in a second step preliminary studies to reduce mask pod influence and contamination due to material out gassing. Approach and techniques: A specific assessment of environmental / molecular contamination along the supply chain was performed by all partners. After previous work presented at EMLC 07, further studies were performed on real time contamination measurement pod at different sites locations (including Mask manufacturing site, blank manufacturing sites, IC fab). Studies were linked to the main critical issues: cleaning, storage, handling, materials and processes. Contamination measurement campaigns were carried out along the mask supply chain using specific Adixen analyzer in order to monitor in real time organic contaminants (ppb level) in mask pods. Key results would be presented: VOC, AMC and humidity level on different kinds of mask carriers, impact of basic cleaning on pod outgassing measurement (VOC, NH3), and process influence on pod contamination... In a second step, preliminary specific pod conditioning studies for better pod environment were performed based on Adixen vacuum process. Process influence had been experimentally measured in term of molecular outgassing from mask pods. Different AMC experimental characterization methods had been carried out leading to results on a wide range of organic and inorganic

  20. Shadows Alter Facial Expressions of Noh Masks

    Science.gov (United States)

    Kawai, Nobuyuki; Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo

    2013-01-01

    Background A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers’ recognition of the emotional expressions. Methodology/Principal Findings In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. Conclusions/Significance Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa’s smile. They also agree with the aesthetic principle of Japanese traditional art “yugen (profound grace and subtlety)”, which highly appreciates subtle emotional expressions in the darkness. PMID:23940748

  1. Fast mask writers: technology options and considerations

    Science.gov (United States)

    Litt, Lloyd C.; Groves, Timothy; Hughes, Greg

    2011-04-01

    The semiconductor industry is under constant pressure to reduce production costs even as the complexity of technology increases. Lithography represents the most expensive process due to its high capital equipment costs and the implementation of low-k1 lithographic processes, which have added to the complexity of making masks because of the greater use of optical proximity correction, pixelated masks, and double or triple patterning. Each of these mask technologies allows the production of semiconductors at future nodes while extending the utility of current immersion tools. Low-k1 patterning complexity combined with increased data due to smaller feature sizes is driving extremely long mask write times. While a majority of the industry is willing to accept times of up to 24 hours, evidence suggests that the write times for many masks at the 22 nm node and beyond will be significantly longer. It has been estimated that funding on the order of 50M to 90M for non-recurring engineering (NRE) costs will be required to develop a multiple beam mask writer system, yet the business case to recover this kind of investment is not strong. Moreover, funding such a development poses a high risk for an individual supplier. The structure of the mask fabrication marketplace separates the mask writer equipment customer (the mask supplier) from the final customer (wafer manufacturer) that will be most effected by the increase in mask cost that will result if a high speed mask writer is not available. Since no individual company will likely risk entering this market, some type of industry-wide funding model will be needed.

  2. Automatic circuit analysis based on mask information

    International Nuclear Information System (INIS)

    Preas, B.T.; Lindsay, B.W.; Gwyn, C.W.

    1976-01-01

    The Circuit Mask Translator (CMAT) code has been developed which converts integrated circuit mask information into a circuit schematic. Logical operations, pattern recognition, and special functions are used to identify and interconnect diodes, transistors, capacitors, and resistances. The circuit topology provided by the translator is compatible with the input required for a circuit analysis program

  3. Fourier phasing with phase-uncertain mask

    International Nuclear Information System (INIS)

    Fannjiang, Albert; Liao, Wenjing

    2013-01-01

    Fourier phasing is the problem of retrieving Fourier phase information from Fourier intensity data. The standard Fourier phase retrieval (without a mask) is known to have many solutions which cause the standard phasing algorithms to stagnate and produce wrong or inaccurate solutions. In this paper Fourier phase retrieval is carried out with the introduction of a randomly fabricated mask in measurement and reconstruction. Highly probable uniqueness of solution, up to a global phase, was previously proved with exact knowledge of the mask. Here the uniqueness result is extended to the case where only rough information about the mask’s phases is assumed. The exponential probability bound for uniqueness is given in terms of the uncertainty-to-diversity ratio of the unknown mask. New phasing algorithms alternating between the object update and the mask update are systematically tested and demonstrated to have the capability of recovering both the object and the mask (within the object support) simultaneously, consistent with the uniqueness result. Phasing with a phase-uncertain mask is shown to be robust with respect to the correlation in the mask as well as the Gaussian and Poisson noises. (paper)

  4. Ipsilateral masking between acoustic and electric stimulations.

    Science.gov (United States)

    Lin, Payton; Turner, Christopher W; Gantz, Bruce J; Djalilian, Hamid R; Zeng, Fan-Gang

    2011-08-01

    Residual acoustic hearing can be preserved in the same ear following cochlear implantation with minimally traumatic surgical techniques and short-electrode arrays. The combined electric-acoustic stimulation significantly improves cochlear implant performance, particularly speech recognition in noise. The present study measures simultaneous masking by electric pulses on acoustic pure tones, or vice versa, to investigate electric-acoustic interactions and their underlying psychophysical mechanisms. Six subjects, with acoustic hearing preserved at low frequencies in their implanted ear, participated in the study. One subject had a fully inserted 24 mm Nucleus Freedom array and five subjects had Iowa/Nucleus hybrid implants that were only 10 mm in length. Electric masking data of the long-electrode subject showed that stimulation from the most apical electrodes produced threshold elevations over 10 dB for 500, 625, and 750 Hz probe tones, but no elevation for 125 and 250 Hz tones. On the contrary, electric stimulation did not produce any electric masking in the short-electrode subjects. In the acoustic masking experiment, 125-750 Hz pure tones were used to acoustically mask electric stimulation. The acoustic masking results showed that, independent of pure tone frequency, both long- and short-electrode subjects showed threshold elevations at apical and basal electrodes. The present results can be interpreted in terms of underlying physiological mechanisms related to either place-dependent peripheral masking or place-independent central masking.

  5. Computing Challenges in Coded Mask Imaging

    Science.gov (United States)

    Skinner, Gerald

    2009-01-01

    This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

  6. Masked hypertension, a review of the literature.

    NARCIS (Netherlands)

    Verberk, W.J.; Thien, Th.; Leeuw, P.W. de

    2007-01-01

    Masked hypertension (blood pressure that is normal in the physicians' office but elevated elsewhere) is a common phenomenon as prevalence among studies varies from 8 to 45% and is seen at all ages. large discrepancies, however, exist between studies that have dealt with masked hypertension. It is of

  7. Family skills for overcoming adversity

    Directory of Open Access Journals (Sweden)

    Mónica Patricia Ardila Hernández

    2013-12-01

    Full Text Available This section draws on research four families in displacement in Tunja Boyacá step of this research is to present the problem of displacement from another different look that has embargoed regarding this topic. Critical reflection was raised from resilient approach Parsons theory in order to understand families immersed in this conflict as change agents capable of adapting to a new system and overcome adversity. Within this scheme is used to obtain qualitative research of the following categories : adaptation to the new social context risk factors present in families and protective factors.

  8. Unmasking Zorro: functional importance of the facial mask in the Masked Shrike (Lanius nubicus)

    OpenAIRE

    Reuven Yosef; Piotr Zduniak; Piotr Tryjanowski

    2012-01-01

    The facial mask is a prominent feature in the animal kingdom. We hypothesized that the facial mask of shrikes allows them to hunt into the sun, which accords them detection and surprise-attack capabilities. We conducted a field experiment to determine whether the mask facilitated foraging while facing into the sun. Male shrikes with white-painted masks hunted facing away from the sun more than birds with black-painted masks, which are the natural color, and more than individuals in the contro...

  9. New data on masking reagents in complexometry

    International Nuclear Information System (INIS)

    Yurist, I.M.; Talmud, M.M.; Zajtsev, P.M.

    1985-01-01

    Recent literature data on employing inorganic and organic oxygen-, nitrogen- and sulfur-containing substances as masking reagents (MR) in complexonometry of alkali earths, rare earths and transition elements are reviewed for the period of 1971-1983. Effectiveness of any type of MR is shown to be dependent on the electron configuration of a cation being masked. Sr, La, Th, V(6), Zr, Hf, V(5), Nb(5), Ta(5), Mo(6), W(6) a.o. are masked by oxygen-containing ligands. Zn, Cd, Fe(2, 3), Co(2, 3), Ni, etc. are masked by nitrogen- and sulfur-bearing ligands. Thiocompounds mask mainly In, Tl(3), Sn(2), Pb, Bi

  10. Comparison of face masks in the bag-mask ventilation of a manikin.

    Science.gov (United States)

    Redfern, D; Rassam, S; Stacey, M R; Mecklenburgh, J S

    2006-02-01

    We conducted a study investigating the effectiveness of four face mask designs in the bag-mask ventilation of a special manikin adapted to simulate a difficult airway. Forty-eight anaesthetists volunteered to bag-mask ventilate the manikin for 3 min with four different face masks. The primary outcome of the study was to calculate mean percentage leak from the face masks over 3 min. Anaesthetists were also asked to rate the face masks using a visual analogue score. The single-use scented intersurgical face mask had the lowest mean leak (20%). This was significantly lower than the mean leak from the single-use, cushioned 7,000 series Air Safety Ltd. face mask (24%) and the reusable silicone Laerdal face mask (27%) but not significantly lower than the mean leak from the reusable anatomical intersurgical face mask (23%). There was a large variation in both performance and satisfaction between anaesthetists with each design. This highlights the importance of having a variety of face masks available for emergency use.

  11. Nasal mask ventilation is better than face mask ventilation in edentulous patients.

    Science.gov (United States)

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients.

  12. An interactive tool for gamut masking

    Science.gov (United States)

    Song, Ying; Lau, Cheryl; Süsstrunk, Sabine

    2014-02-01

    Artists often want to change the colors of an image to achieve a particular aesthetic goal. For example, they might limit colors to a warm or cool color scheme to create an image with a certain mood or feeling. Gamut masking is a technique that artists use to limit the set of colors they can paint with. They draw a mask over a color wheel and only use the hues within the mask. However, creating the color palette from the mask and applying the colors to the image requires skill. We propose an interactive tool for gamut masking that allows amateur artists to create an image with a desired mood or feeling. Our system extracts a 3D color gamut from the 2D user-drawn mask and maps the image to this gamut. The user can draw a different gamut mask or locally refine the image colors. Our voxel grid gamut representation allows us to represent gamuts of any shape, and our cluster-based image representation allows the user to change colors locally.

  13. Reflective masks for extreme ultraviolet lithography

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Khanh Bao [Univ. of California, Berkeley, CA (United States)

    1994-05-01

    Extreme ultraviolet lithographic masks are made by patterning multilayer reflective coatings with high normal incidence reflectivity. Masks can be patterned by depositing a patterned absorber layer above the coating or by etching the pattern directly into the coating itself. Electromagnetic simulations showed that absorber-overlayer masks have superior imaging characteristics over etched masks (less sensitive to incident angles and pattern profiles). In an EUVL absorber overlayer mask, defects can occur in the mask substrate, reflective coating, and absorber pattern. Electromagnetic simulations showed that substrate defects cause the most severe image degradation. A printability study of substrate defects for absorber overlayer masks showed that printability of 25 nm high substrate defects are comparable to defects in optical lithography. Simulations also indicated that the manner in which the defects are covered by multilayer reflective coatings can affect printability. Coverage profiles that result in large lateral spreading of defect geometries amplify the printability of the defects by increasing their effective sizes. Coverage profiles of Mo/Si coatings deposited above defects were studied by atomic force microscopy and TEM. Results showed that lateral spread of defect geometry is proportional to height. Undercut at defect also increases the lateral spread. Reductions in defect heights were observed for 0.15 μm wide defect lines. A long-term study of Mo/Si coating reflectivity revealed that Mo/Si coatings with Mo as the top layer suffer significant reductions in reflectivity over time due to oxidation.

  14. Effect of Ibuprofen on masking endodontic diagnosis.

    Science.gov (United States)

    Read, Jason K; McClanahan, Scott B; Khan, Asma A; Lunos, Scott; Bowles, Walter R

    2014-08-01

    An accurate diagnosis is of upmost importance before initiating endodontic treatment; yet, there are occasions when the practitioner cannot reproduce the patient's chief complaint because the patient has become asymptomatic. Ibuprofen taken beforehand may "mask" or eliminate the patient's symptoms. In fact, 64%-83% of patients with dental pain take analgesics before seeing a dentist. The purpose of this study was to examine the possible "masking" effect of ibuprofen on endodontic diagnostic tests. Forty-two patients with endodontic pain underwent testing (cold, percussion, palpation, and bite force measurement) and then received either placebo or 800 mg ibuprofen. Both patients and operators were blinded to the medication received. One hour later, diagnostic testing was repeated and compared with pretreatment testing. Ibuprofen affected testing values for vital teeth by masking palpation 40%, percussion 25%, and cold 25% on affected teeth with symptomatic irreversible pulpitis and symptomatic apical periodontitis. There was no observed masking effect in the placebo group on palpation, percussion, or cold values. When nonvital teeth were included, the masking effect of ibuprofen was decreased. However, little masking occurred with the bite force measurement differences. Analgesics taken before the dental appointment can affect endodontic diagnostic testing results. Bite force measurements can assist in identifying the offending tooth in cases in which analgesics "mask" the endodontic diagnosis. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Polymer Masks for nanostructuring of graphene

    DEFF Research Database (Denmark)

    Shvets, Violetta

    This PhD project is a part of Center for Nanostructured Graphene (CNG) activities. The aim of the project is to develop a new lithography method for creation of highly ordered nanostructures with as small as possible feature and period sizes. The method should be applicable for graphene nanostruc...... demonstrated the opening of what could be interpreted as a band gap....... polymer masks is developed. Mask fabrication is realized by microtoming of 30-60 nm thin sections from pre-aligned polymer monoliths with different morphologies. The resulting polymer masks are then transferred to both silicon and graphene substrates. Hexagonally packed hole patterns with 10 nm hole...

  16. When Bad Masks Turn Good

    Science.gov (United States)

    Abraham, Roberto G.

    In keeping with the spirit of a meeting on ‘masks,' this talk presents two short stories on the theme of dust. In the first, dust plays the familiar role of the evil obscurer, the enemy to bedefeated by the cunning observer in order to allow a key future technology (adaptive optics) to be exploited fully by heroic astronomers. In the second story, dust itself emerges as the improbable hero, in the form of a circumstellar debris disks. I will present evidence of a puzzling near-infrared excess in the continuum of high-redshift galaxies and will argue that the seemingly improbable origin of this IR excess is a population of young circumstellar disks formed around high-mass stars in distant galaxies. Assuming circumstellar disks extend down to lower masses,as they do in our own Galaxy, the excess emission presents us with an exciting opportunity to measure the formation rate of planetary systems in distant galaxies at cosmic epochs before our own solar system formed.

  17. Evaluation of Criteria to Detect Masked Hypertension

    Science.gov (United States)

    Booth, John N.; Muntner, Paul; Diaz, Keith M.; Viera, Anthony J.; Bello, Natalie A.; Schwartz, Joseph E.; Shimbo, Daichi

    2016-01-01

    The prevalence of masked hypertension, out-of-clinic daytime systolic/diastolic blood pressure (SBP/DBP)≥135/85 mmHg on ambulatory blood pressure monitoring (ABPM) among adults with clinic SBP/DBPABPM testing criterion. In a derivation cohort (n=695), the index was clinic SBP+1.3*clinic DBP. In an external validation cohort (n=675), the sensitivity for masked hypertension using an index ≥190 mmHg and ≥217 mmHg and prehypertension status was 98.5%, 71.5% and 82.5%, respectively. Using NHANES data (n=11,778), we estimated that these thresholds would refer 118.6, 44.4 and 59.3 million US adults, respectively, to ABPM screening for masked hypertension. In conclusion, the CBP index provides a useful approach to identify candidates for masked hypertension screening using ABPM. PMID:27126770

  18. Active mask segmentation of fluorescence microscope images.

    Science.gov (United States)

    Srinivasa, Gowri; Fickus, Matthew C; Guo, Yusong; Linstedt, Adam D; Kovacević, Jelena

    2009-08-01

    We propose a new active mask algorithm for the segmentation of fluorescence microscope images of punctate patterns. It combines the (a) flexibility offered by active-contour methods, (b) speed offered by multiresolution methods, (c) smoothing offered by multiscale methods, and (d) statistical modeling offered by region-growing methods into a fast and accurate segmentation tool. The framework moves from the idea of the "contour" to that of "inside and outside," or masks, allowing for easy multidimensional segmentation. It adapts to the topology of the image through the use of multiple masks. The algorithm is almost invariant under initialization, allowing for random initialization, and uses a few easily tunable parameters. Experiments show that the active mask algorithm matches the ground truth well and outperforms the algorithm widely used in fluorescence microscopy, seeded watershed, both qualitatively, as well as quantitatively.

  19. Masking of aluminum surface against anodizing

    Science.gov (United States)

    Crawford, G. B.; Thompson, R. E.

    1969-01-01

    Masking material and a thickening agent preserve limited unanodized areas when aluminum surfaces are anodized with chromic acid. For protection of large areas it combines well with a certain self-adhesive plastic tape.

  20. Mask-induced aberration in EUV lithography

    Science.gov (United States)

    Nakajima, Yumi; Sato, Takashi; Inanami, Ryoichi; Nakasugi, Tetsuro; Higashiki, Tatsuhiko

    2009-04-01

    We estimated aberrations using Zernike sensitivity analysis. We found the difference of the tolerated aberration with line direction for illumination. The tolerated aberration of perpendicular line for illumination is much smaller than that of parallel line. We consider this difference to be attributable to the mask 3D effect. We call it mask-induced aberration. In the case of the perpendicular line for illumination, there was a difference in CD between right line and left line without aberration. In this report, we discuss the possibility of pattern formation in NA 0.25 generation EUV lithography tool. In perpendicular pattern for EUV light, the dominant part of aberration is mask-induced aberration. In EUV lithography, pattern correction based on the mask topography effect will be more important.

  1. Nablus mask-like facial syndrome

    DEFF Research Database (Denmark)

    Allanson, Judith; Smith, Amanda; Hare, Heather

    2012-01-01

    Nablus mask-like facial syndrome (NMLFS) has many distinctive phenotypic features, particularly tight glistening skin with reduced facial expression, blepharophimosis, telecanthus, bulky nasal tip, abnormal external ear architecture, upswept frontal hairline, and sparse eyebrows. Over the last few...

  2. The fastest saccadic responses escape visual masking

    DEFF Research Database (Denmark)

    Crouzet, Sébastien M.; Overgaard, Morten; Busch, Niko A.

    2014-01-01

    Object-substitution masking (OSM) occurs when a briefly presented target in a search array is surrounded by small dots that remain visible after the target disappears. The reduction of target visibility occurring after OSM has been suggested to result from a specific interference with reentrant......, which gives access to very early stages of visual processing, target visibility was reduced either by OSM, conventional backward masking, or low stimulus contrast. A general reduction of performance was observed in all three conditions. However, the fastest saccades did not show any sign of interference...... under either OSM or backward masking, as they did under the low-contrast condition. This finding supports the hypothesis that masking interferes mostly with reentrant processing at later stages, while leaving early feedforward processing largely intact....

  3. Attentional capture by masked colour singletons.

    Science.gov (United States)

    Ansorge, Ulrich; Horstmann, Gernot; Worschech, Franziska

    2010-09-15

    We tested under which conditions a colour singleton of which an observer is unaware captures attention. To prevent visual awareness of the colour singleton, we used backward masking. We find that a masked colour singleton cue captures attention if it matches the observer's goal to search for target colours but not if it is task-irrelevant. This is also reflected in event-related potentials to the visible target: the masked goal-matching cue elicits an attentional potential (N2pc) in a target search task. By contrast, a non-matching but equally strong masked colour singleton cue failed to elicit a capture effect and an N2pc. Results are discussed with regard to currently pertaining conceptions of attentional capture by colour singletons. Copyright 2010 Elsevier Ltd. All rights reserved.

  4. Design of Data Masking Architecture and Analysis of Data Masking Techniques for Testing

    OpenAIRE

    Ravikumar G K,; Manjunath T. N,; Ravindra S. Hegadi,; Archana.R.A

    2011-01-01

    Data masking is the process of obscuring-masking, specific data elements within data stores. It ensures that sensitive data is replaced with realistic but not real data. The goal is that sensitive customer information is not available outside of the authorized environment. Data masking is typically done while provisioning nonproduction environments so that copies created to support test and development processes are not exposing sensitive information and thus avoiding risks of leaking. Maskin...

  5. Effects of hard mask etch on final topography of advanced phase shift masks

    Science.gov (United States)

    Hortenbach, Olga; Rolff, Haiko; Lajn, Alexander; Baessler, Martin

    2017-07-01

    Continuous shrinking of the semiconductor device dimensions demands steady improvements of the lithographic resolution on wafer level. These requirements challenge the photomask industry to further improve the mask quality in all relevant printing characteristics. In this paper topography of the Phase Shift Masks (PSM) was investigated. Effects of hard mask etch on phase shift uniformity and mask absorber profile were studied. Design of experiments method (DoE) was used for the process optimization, whereas gas composition, bias power of the hard mask main etch and bias power of the over-etch were varied. In addition, influence of the over-etch time was examined at the end of the experiment. Absorber depth uniformity, sidewall angle (SWA), reactive ion etch lag (RIE lag) and through pitch (TP) dependence were analyzed. Measurements were performed by means of Atomic-force microscopy (AFM) using critical dimension (CD) mode with a boot-shaped tip. Scanning electron microscope (SEM) cross-section images were prepared to verify the profile quality. Finally CD analysis was performed to confirm the optimal etch conditions. Significant dependence of the absorber SWA on hard mask (HM) etch conditions was observed revealing an improvement potential for the mask absorber profile. It was found that hard mask etch can leave a depth footprint in the absorber layer. Thus, the etch depth uniformity of hard mask etch is crucial for achieving a uniform phase shift over the active mask area. The optimized hard mask etch process results in significantly improved mask topography without deterioration of tight CD specifications.

  6. Carcinoembryonic antigen (CEA)

    International Nuclear Information System (INIS)

    Ephraim, K.H.; Cox, P.H.; Hamer, C.J.A. v.d.; Berends, W.; Delhez, H.

    1977-01-01

    The carcinoembryonic antigen (CEA) is a complex of antigen determinants and also the carrier of these determinants. Chemically it is a glycoprotein. Its occurrence in blood serum or urine is correlated with malignant disease. Several radioimmunoassays (RIA) have been developed, one by Hoffmann-Laroche and one by the Rotterdam Radiotherapeutic Institute. Both methods and the Hoffmann assay kit are tested. Specifications are given for isolation of the antigen, preparation of the antiserum, and the execution of the RIA. Biochemical and clinical aspects are discussed

  7. Active Mask Segmentation of Fluorescence Microscope Images

    OpenAIRE

    Srinivasa, Gowri; Fickus, Matthew C.; Guo, Yusong; Linstedt, Adam D.; Kovačević, Jelena

    2009-01-01

    We propose a new active mask algorithm for the segmentation of fluorescence microscope images of punctate patterns. It combines the (a) flexibility offered by active-contour methods, (b) speed offered by multiresolution methods, (c) smoothing offered by multiscale methods, and (d) statistical modeling offered by region-growing methods into a fast and accurate segmentation tool. The framework moves from the idea of the “contour” to that of “inside and outside”, or, masks, allowing for easy mul...

  8. Refinement of the CALIOP cloud mask algorithm

    Science.gov (United States)

    Katagiri, Shuichiro; Sato, Kaori; Ohta, Kohei; Okamoto, Hajime

    2018-04-01

    A modified cloud mask algorithm was applied to the CALIOP data to have more ability to detect the clouds in the lower atmosphere. In this algorithm, we also adopt the fully attenuation discrimination and the remain noise estimation using the data obtained at an altitude of 40 km to avoid contamination of stratospheric aerosols. The new cloud mask shows an increase in the lower cloud fraction. Comparison of the results to the data observed with a PML ground observation was also made.

  9. Masked Uncontrolled Hypertension in CKD.

    Science.gov (United States)

    Agarwal, Rajiv; Pappas, Maria K; Sinha, Arjun D

    2016-03-01

    Masked uncontrolled hypertension (MUCH) is diagnosed in patients treated for hypertension who are normotensive in the clinic but hypertensive outside. In this study of 333 veterans with CKD, we prospectively evaluated the prevalence of MUCH as determined by ambulatory BP monitoring using three definitions of hypertension (daytime hypertension ≥135/85 mmHg; either nighttime hypertension ≥120/70 mmHg or daytime hypertension; and 24-hour hypertension ≥130/80 mmHg) or by home BP monitoring (hypertension ≥135/85 mmHg). The prevalence of MUCH was 26.7% by daytime ambulatory BP, 32.8% by 24-hour ambulatory BP, 56.1% by daytime or night-time ambulatory BP, and 50.8% by home BP. To assess the reproducibility of the diagnosis, we repeated these measurements after 4 weeks. Agreement in MUCH diagnosis by ambulatory BP was 75-78% (κ coefficient for agreement, 0.44-0.51), depending on the definition used. In contrast, home BP showed an agreement of only 63% and a κ coefficient of 0.25. Prevalence of MUCH increased with increasing clinic systolic BP: 2% in the 90-110 mmHg group, 17% in the 110-119 mmHg group, 34% in the 120-129 mmHg group, and 66% in the 130-139 mmHg group. Clinic BP was a good determinant of MUCH (receiver operating characteristic area under the curve 0.82; 95% confidence interval 0.76-0.87). In diagnosing MUCH, home BP was not different from clinic BP. In conclusion, among people with CKD, MUCH is common and reproducible, and should be suspected when clinic BP is in the prehypertensive range. Confirmation of MUCH diagnosis should rely on ambulatory BP monitoring. Copyright © 2016 by the American Society of Nephrology.

  10. Seismic signals hard clipping overcoming

    Science.gov (United States)

    Olszowa, Paula; Sokolowski, Jakub

    2018-01-01

    In signal processing the clipping is understand as the phenomenon of limiting the signal beyond certain threshold. It is often related to overloading of a sensor. Two particular types of clipping are being recognized: soft and hard. Beyond the limiting value soft clipping reduces the signal real gain while the hard clipping stiffly sets the signal values at the limit. In both cases certain amount of signal information is lost. Obviously if one possess the model which describes the considered signal and the threshold value (which might be slightly more difficult to obtain in the soft clipping case), the attempt of restoring the signal can be made. Commonly it is assumed that the seismic signals take form of an impulse response of some specific system. This may lead to belief that the sine wave may be the most appropriate to fit in the clipping period. However, this should be tested. In this paper the possibility of overcoming the hard clipping in seismic signals originating from a geoseismic station belonging to an underground mine is considered. A set of raw signals will be hard-clipped manually and then couple different functions will be fitted and compared in terms of least squares. The results will be then analysed.

  11. Masking Period Patterns & Forward Masking for Speech-Shaped Noise: Age-related effects

    Science.gov (United States)

    Grose, John H.; Menezes, Denise C.; Porter, Heather L.; Griz, Silvana

    2015-01-01

    Objective The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to non-simultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Design Participants included younger (n = 11), middle-aged (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions, and assessed how well the temporal window fits accounted for these data. Results The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. Conclusions This study demonstrated an age-related increase in susceptibility to non-simultaneous masking, supporting the hypothesis that exacerbated non-simultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data suggesting an association between susceptibility to forward masking and speech understanding in modulated noise. PMID:26230495

  12. Modulation cues influence binaural masking-level difference in masking-pattern experiments.

    Science.gov (United States)

    Nitschmann, Marc; Verhey, Jesko L

    2012-03-01

    Binaural masking patterns show a steep decrease in the binaural masking-level difference (BMLD) when masker and signal have no frequency component in common. Experimental threshold data are presented together with model simulations for a diotic masker centered at 250 or 500 Hz and a bandwidth of 10 or 100 Hz masking a sinusoid interaurally in phase (S(0)) or in antiphase (S(π)). Simulations with a binaural model, including a modulation filterbank for the monaural analysis, indicate that a large portion of the decrease in the BMLD in remote-masking conditions may be due to an additional modulation cue available for monaural detection. © 2012 Acoustical Society of America

  13. Masking Period Patterns and Forward Masking for Speech-Shaped Noise: Age-Related Effects.

    Science.gov (United States)

    Grose, John H; Menezes, Denise C; Porter, Heather L; Griz, Silvana

    2016-01-01

    The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to nonsimultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Participants included younger (n = 11), middle-age (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions and assessed how well the temporal window fits accounted for these data. The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. This study demonstrated an age-related increase in susceptibility to nonsimultaneous masking, supporting the hypothesis that exacerbated nonsimultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data, suggesting an association between susceptibility to forward masking and speech understanding in modulated noise.

  14. Supreme Laryngeal Mask Airway versus Face Mask during Neonatal Resuscitation: A Randomized Controlled Trial.

    Science.gov (United States)

    Trevisanuto, Daniele; Cavallin, Francesco; Nguyen, Loi Ngoc; Nguyen, Tien Viet; Tran, Linh Dieu; Tran, Chien Dinh; Doglioni, Nicoletta; Micaglio, Massimo; Moccia, Luciano

    2015-08-01

    To assess the effectiveness of supreme laryngeal mask airway (SLMA) over face mask ventilation for preventing need for endotracheal intubation at birth. We report a prospective, randomized, parallel 1:1, unblinded, controlled trial. After a short-term educational intervention on SLMA use, infants ≥34-week gestation and/or expected birth weight ≥1500 g requiring positive pressure ventilation (PPV) at birth were randomized to resuscitation by SLMA or face mask. The primary outcome was the success rate of the resuscitation devices (SLMA or face mask) defined as the achievement of an effective PPV preventing the need for endotracheal intubation. We enrolled 142 patients (71 in SLMA and 71 in face mask group, respectively). Successful resuscitation rate was significantly higher with the SLMA compared with face mask ventilation (91.5% vs 78.9%; P = .03). Apgar score at 5 minutes was significantly higher in SLMA than in face mask group (P = .02). Neonatal intensive care unit admission rate was significantly lower in SLMA than in face mask group (P = .02). No complications related to the procedure occurred. In newborns with gestational age ≥34 weeks and/or expected birth weight ≥1500 g needing PPV at birth, the SLMA is more effective than face mask to prevent endotracheal intubation. The SLMA is effective in clinical practice after a short-term educational intervention. Registered with ClinicalTrials.gov: NCT01963936. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Phase mask coronagraphy at JPL and Palomar

    Directory of Open Access Journals (Sweden)

    Serabyn E.

    2011-07-01

    Full Text Available For the imaging of faint companions, phase mask coronagraphy has the dual advantages of a small inner working angle and high throughput. This paper summarizes our recent work in developing phase masks and in demonstrating their capabilities at JPL. Four-quadrant phase masks have been manufactured at JPL by means of both evaporation and etching, and we have been developing liquid crystal vortex phase masks in partnership with a commercial vendor. Both types of mask have been used with our extreme adaptive optics well-corrected subaperture at Palomar to detect known brown dwarf companions as close as ~ 2.5 λ/D to stars. Moreover, our recent vortex masks perform very well in laboratory tests, with a demonstrated infrared contrast of about 10−6 at 3 λ/D, and contrasts of a few 10−7 with an initial optical wavelength device. The demonstrated performance already meets the needs of ground-based extreme adaptive optics coronagraphy, and further planned improvements are aimed at reaching the 10−10 contrast needed for terrestrial exoplanet detection with a space-based coronagraph.

  16. Conceptual Masking: How One Picture Captures Attention from Another Picture.

    Science.gov (United States)

    Loftus, Geoffrey R.; And Others

    1988-01-01

    Five experiments studied operations of conceptual masking--the reduction of conceptual memory performance for an initial stimulus when it is followed by a masking picture process. The subjects were 337 undergraduates at the University of Washington (Seattle). Conceptual masking is distinguished from perceptual masking. (TJH)

  17. Analysis and test of laws for backward (metacontrast) masking

    NARCIS (Netherlands)

    Francis, G.; Rothmayer, M.; Hermens, F.

    2004-01-01

    In backward visual masking, it is common to find that the mask has its biggest effect when it follows the target by several tens of milliseconds. Research in the 1960s and 1970s suggested that masking effects were best characterized by the stimulus onset asynchrony (SOA) between the target and mask.

  18. Orientation tuning of contrast masking caused by motion streaks.

    Science.gov (United States)

    Apthorp, Deborah; Cass, John; Alais, David

    2010-08-01

    We investigated whether the oriented trails of blur left by fast-moving dots (i.e., "motion streaks") effectively mask grating targets. Using a classic overlay masking paradigm, we varied mask contrast and target orientation to reveal underlying tuning. Fast-moving Gaussian blob arrays elevated thresholds for detection of static gratings, both monoptically and dichoptically. Monoptic masking at high mask (i.e., streak) contrasts is tuned for orientation and exhibits a similar bandwidth to masking functions obtained with grating stimuli (∼30 degrees). Dichoptic masking fails to show reliable orientation-tuned masking, but dichoptic masks at very low contrast produce a narrowly tuned facilitation (∼17 degrees). For iso-oriented streak masks and grating targets, we also explored masking as a function of mask contrast. Interestingly, dichoptic masking shows a classic "dipper"-like TVC function, whereas monoptic masking shows no dip and a steeper "handle". There is a very strong unoriented component to the masking, which we attribute to transiently biased temporal frequency masking. Fourier analysis of "motion streak" images shows interesting differences between dichoptic and monoptic functions and the information in the stimulus. Our data add weight to the growing body of evidence that the oriented blur of motion streaks contributes to the processing of fast motion signals.

  19. 37 CFR 211.3 - Mask work fees.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Mask work fees. 211.3 Section... PROCEDURES MASK WORK PROTECTION § 211.3 Mask work fees. (a) Section 201.3 of this chapter prescribes the fees or charges established by the Register of Copyrights for services relating to mask works. (b) Section...

  20. 42 CFR 84.117 - Gas mask containers; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Gas mask containers; minimum requirements. 84.117... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.117 Gas mask containers; minimum requirements. (a) Gas masks shall be equipped with a substantial...

  1. 21 CFR 868.5560 - Gas mask head strap.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas mask head strap. 868.5560 Section 868.5560...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5560 Gas mask head strap. (a) Identification. A gas mask head strap is a device used to hold an anesthetic gas mask in position on a patient's...

  2. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  3. Heating plant overcomes coal crisis

    International Nuclear Information System (INIS)

    Sobinkovic, B.

    2006-01-01

    At the last moment Kosice managed to overcome the threat of a more than 30-percent heating price increase. The biggest local heat producer, Teplaren Kosice, is running out of coal supplies. The only alternative would be gas, which is far more expensive. The reason for this situation was a dispute of the heating plant with one of its suppliers, Kimex. Some days ago, the dispute was settled and the heating plant is now expecting the first wagon loads of coal to arrive. These are eagerly awaited, as its supplies will not last for more than a month. It all started with a public tender for a coal supplier. Teplaren Kosice (TEKO) announced the tender for the delivery of 120,000 tons of coal in June. Kimex, one of the traditional and biggest suppliers, was disqualified in the course of the tender. The winners of the tender were Slovenergo, Bratislava and S-Plus Trade, Vranov nad Toplou. TEKO signed contracts with them but a district court in Kosice prohibited the company from purchasing coal from these contractors. Kimex filed a complaint claiming that it was disqualified unlawfully. Based on this the court issued a preliminary ruling prohibiting the purchase of coal from the winners of the tender. The heating plant had to wait for the final verdict. The problem was then solved by the company's new Board of Directors, who were appointed in mid October who managed to sign new contracts with the two winners and Kimex. The new contracts cover the purchase of 150-thousand tons of coal, which is 30,000 more than in the original tender specification. Each company will supply one third. (authors)

  4. Fabrication of rectangular cross-sectional microchannels on PMMA with a CO2 laser and underwater fabricated copper mask

    Science.gov (United States)

    Prakash, Shashi; Kumar, Subrata

    2017-09-01

    CO2 lasers are commonly used for fabricating polymer based microfluidic devices. Despite several key advantages like low cost, time effectiveness, easy to operate and no requirement of clean room facility, CO2 lasers suffer from few disadvantages like thermal bulging, improper dimensional control, difficulty to produce microchannels of other than Gaussian cross sectional shapes and inclined surface walls. Many microfluidic devices require square or rectangular cross-sections which are difficult to produce using normal CO2 laser procedures. In this work, a thin copper sheet of 40 μm was used as a mask above the PMMA (Polymethyl-methacrylate) substrate while fabricating the microchannels utilizing the raster scanning feature of the CO2 lasers. Microchannels with different width dimensions were fabricated utilizing a CO2 laser in with mask and without-mask conditions. A comparison of both the fabricating process has been made. It was found that microchannels with U shape cross section and rectangular cross-section can efficiently be produced using the with mask technique. In addition to this, this technique can provide perfect dimensional control and better surface quality of the microchannel walls. Such a microchannel fabrication process do not require any post-processing. The fabrication of mask using a nanosecond fiber laser has been discussed in details. An underwater laser fabrication method was adopted to overcome heat related defects in mask preparation. Overall, the technique was found to be easy to adopt and significant improvements were observed in microchannel fabrication.

  5. Perception of Scary Halloween Masks by Zoo Animals and Humans

    OpenAIRE

    Sinnott, Joan M.; Speaker, H. Anton; Powell, Laura A.; Mosteller, Kelly W.

    2012-01-01

    Zoo animals were tested to see if they perceived the scary nature of Halloween masks, using a procedure that measured the avoidance response latency to take food from a masked human experimenter. Human perception of the masks was also assessed using a rating scale, with results showing that a Bill Clinton mask was rated not scary, while a Vampire mask was rated very scary. Animal results showed that primate latencies correlated significantly with the human ratings, while non-primate latencies...

  6. A super-high angular resolution principle for coded-mask X-ray imaging beyond the diffraction limit of a single pinhole

    International Nuclear Information System (INIS)

    Zhang Chen; Zhang Shuangnan

    2009-01-01

    High angular resolution X-ray imaging is always useful in astrophysics and solar physics. In principle, it can be performed by using coded-mask imaging with a very long mask-detector distance. Previously, the diffraction-interference effect was thought to degrade coded-mask imaging performance dramatically at the low energy end with its very long mask-detector distance. The diffraction-interference effect is described with numerical calculations, and the diffraction-interference cross correlation reconstruction method (DICC) is developed in order to overcome the imaging performance degradation. Based on the DICC, a super-high angular resolution principle (SHARP) for coded-mask X-ray imaging is proposed. The feasibility of coded mask imaging beyond the diffraction limit of a single pinhole is demonstrated with simulations. With the specification that the mask element size is 50 x 50 μm 2 and the mask-detector distance is 50 m, the achieved angular resolution is 0.32 arcsec above about 10 keV and 0.36 arcsec at 1.24 keV (λ = 1 nm), where diffraction cannot be neglected. The on-axis source location accuracy is better than 0.02 arcsec. Potential applications for solar observations and wide-field X-ray monitors are also briefly discussed. (invited reviews)

  7. Simultaneous pure-tone masking : the dependence of masking asymmetries on intensity

    NARCIS (Netherlands)

    Vogten, L.L.M.

    1978-01-01

    Phase locking between probe and masker was used in a series of pure-tone masking experiments. The masker was a stationary sine wave of variable frequency; the probe a fixed-frequency tone burst. We have observed that for small frequency separation the masking behaves asymmetrically around the probe

  8. An etching mask and a method to produce an etching mask

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to an etching mask comprising silicon containing block copolymers produced by self-assembly techniques onto silicon or graphene substrate. Through the use of the etching mask, nanostructures having long linear features having sub-10 nm width can be produced....

  9. [Recognition of visual objects under forward masking. Effects of cathegorial similarity of test and masking stimuli].

    Science.gov (United States)

    Gerasimenko, N Iu; Slavutskaia, A V; Kalinin, S A; Kulikov, M A; Mikhaĭlova, E S

    2013-01-01

    In 38 healthy subjects accuracy and response time were examined during recognition of two categories of images--animals andnonliving objects--under forward masking. We revealed new data that masking effects depended of categorical similarity of target and masking stimuli. The recognition accuracy was the lowest and the response time was the most slow, when the target and masking stimuli belongs to the same category, that was combined with high dispersion of response times. The revealed effects were more clear in the task of animal recognition in comparison with the recognition of nonliving objects. We supposed that the revealed effects connected with interference between cortical representations of the target and masking stimuli and discussed our results in context of cortical interference and negative priming.

  10. Endogenous cueing attenuates object substitution masking.

    Science.gov (United States)

    Germeys, Filip; Pomianowska, I; De Graef, P; Zaenen, P; Verfaillie, K

    2010-07-01

    Object substitution masking (OSM) is a form of visual masking in which a briefly presented target surrounded by four small dots is masked by the continuing presence of the four dots after target offset. A major parameter in the prediction of OSM is the time required for attention to be directed to the target following its onset. Object substitution theory (Di Lollo et al. in J Exp Psychol Gen 129:481-507, 2000) predicts that the sooner attention can be focused at the target's location, the less masking will ensue. However, recently Luiga and Bachmann (Psychol Res 71:634-640, 2007) presented evidence that precueing of attention to the target location prior to target-plus-mask onset by means of a central (endogenous) arrow cue does not reduce OSM. When attention was cued exogenously, OSM was attenuated. Based on these results, Luiga and Bachmann argued that object substitution theory should be adapted by differentiating the ways of directing attention to the target location. The goal of the present study was to further examine the dissociation between the effects of endogenous and exogenous precueing on OSM. Contrary to Luiga and Bachmann, our results show that prior shifts of attention to the target location initiated by both exogenous and endogenous cues reduce OSM as predicted by object substitution theory and its computational model CMOS.

  11. Mitigating mask roughness via pupil filtering

    Science.gov (United States)

    Baylav, B.; Maloney, C.; Levinson, Z.; Bekaert, J.; Vaglio Pret, A.; Smith, B.

    2014-03-01

    The roughness present on the sidewalls of lithographically defined patterns imposes a very important challenge for advanced technology nodes. It can originate from the aerial image or the photoresist chemistry/processing [1]. The latter remains to be the dominant group in ArF and KrF lithography; however, the roughness originating from the mask transferred to the aerial image is gaining more attention [2-9], especially for the imaging conditions with large mask error enhancement factor (MEEF) values. The mask roughness contribution is usually in the low frequency range, which is particularly detrimental to the device performance by causing variations in electrical device parameters on the same chip [10-12]. This paper explains characteristic differences between pupil plane filtering in amplitude and in phase for the purpose of mitigating mask roughness transfer under interference-like lithography imaging conditions, where onedirectional periodic features are to be printed by partially coherent sources. A white noise edge roughness was used to perturbate the mask features for validating the mitigation.

  12. EUV mask process specifics and development challenges

    Science.gov (United States)

    Nesladek, Pavel

    2014-07-01

    EUV lithography is currently the favorite and most promising candidate among the next generation lithography (NGL) technologies. Decade ago the NGL was supposed to be used for 45 nm technology node. Due to introduction of immersion 193nm lithography, double/triple patterning and further techniques, the 193 nm lithography capabilities was greatly improved, so it is expected to be used successfully depending on business decision of the end user down to 10 nm logic. Subsequent technology node will require EUV or DSA alternative technology. Manufacturing and especially process development for EUV technology requires significant number of unique processes, in several cases performed at dedicated tools. Currently several of these tools as e.g. EUV AIMS or actinic reflectometer are not available on site yet. The process development is done using external services /tools with impact on the single unit process development timeline and the uncertainty of the process performance estimation, therefore compromises in process development, caused by assumption about similarities between optical and EUV mask made in experiment planning and omitting of tests are further reasons for challenges to unit process development. Increased defect risk and uncertainty in process qualification are just two examples, which can impact mask quality / process development. The aim of this paper is to identify critical aspects of the EUV mask manufacturing with respect to defects on the mask with focus on mask cleaning and defect repair and discuss the impact of the EUV specific requirements on the experiments needed.

  13. Improved Mask Protected DES using RSA Algorithm

    Directory of Open Access Journals (Sweden)

    Asha Latha S.

    2016-01-01

    Full Text Available The data encryption standard is a pioneering and farsighted standard which helped to set a new paradigm for encryption standards. But now DES is considered to be insecure for some application. Asymmetric mask protected DES is an advanced encryption method for effectively protecting the advanced DES. There are still probabilities to improve its security. This paper propose a method, which introduce a RSA key generation scheme in mask protected DES instead of plain key, which result in enhancement in the security of present asymmetric mask protected DES. We further propose a Vedic mathematical method of RSA implementation which reduce the complexity of computation in RSA block thereby resulting in reduced delay (four timesthat improves the performance of overall system. The software implementation was performed using Xilinx 13.2 and Model-Sim was used for the simulation environment.

  14. Pattern transfer with stabilized nanoparticle etch masks

    International Nuclear Information System (INIS)

    Hogg, Charles R; Majetich, Sara A; Picard, Yoosuf N; Narasimhan, Amrit; Bain, James A

    2013-01-01

    Self-assembled nanoparticle monolayer arrays are used as an etch mask for pattern transfer into Si and SiO x substrates. Crack formation within the array is prevented by electron beam curing to fix the nanoparticles to the substrate, followed by a brief oxygen plasma to remove excess carbon. This leaves a dot array of nanoparticle cores with a minimum gap of 2 nm. Deposition and liftoff can transform the dot array mask into an antidot mask, where the gap is determined by the nanoparticle core diameter. Reactive ion etching is used to transfer the dot and antidot patterns into the substrate. The effect of the gap size on the etching rate is modeled and compared with the experimental results. (paper)

  15. Counteracting Power Analysis Attacks by Masking

    Science.gov (United States)

    Oswald, Elisabeth; Mangard, Stefan

    The publication of power analysis attacks [12] has triggered a lot of research activities. On the one hand these activities have been dedicated toward the development of secure and efficient countermeasures. On the other hand also new and improved attacks have been developed. In fact, there has been a continuous arms race between designers of countermeasures and attackers. This chapter provides a brief overview of the state-of-the art in the arms race in the context of a countermeasure called masking. Masking is a popular countermeasure that has been extensively discussed in the scientific community. Numerous articles have been published that explain different types of masking and that analyze weaknesses of this countermeasure.

  16. Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.

    Science.gov (United States)

    Berlinski, Ariel

    2014-08-01

    Infants and children with respiratory conditions are often prescribed bronchodilators. Face masks are used to facilitate the administration of nebulized therapy in patients unable to use a mouthpiece. Masks incorporate holes into their design, and their occlusion during aerosol delivery has been a common practice. Masks are available in different sizes and different dead volumes. The aim of this study was to compare the effect of different degrees of occlusion of the mask holes and different mask dead space on the amount of nebulized albuterol available at the mouth opening in a model of a spontaneously breathing child. A breathing simulator mimicking infant (tidal volume [VT] = 50 mL, breathing frequency = 30 breaths/min, inspiratory-expiratory ratio [I:E] = 1:3), child (VT = 155 mL, breathing frequency = 25 breaths/min, I:E = 1:2), and adult (VT = 500 mL, breathing frequency = 15 breaths/min, I:E = 1:2) breathing patterns was connected to a collection filter hidden behind a face plate. A pediatric size mask and an adult size mask connected to a continuous output jet nebulizer were sealed to the face plate. Three nebulizers were loaded with albuterol sulfate (2.5 mg/3 mL) and operated with 6 L/min compressed air for 5 min. Experiments were repeated with different degrees of occlusion (0%, 50%, and 90%). Albuterol was extracted from the filter and measured with a spectrophotometer at 276 nm. Occlusion of the holes in the large mask did not increase the amount of albuterol in any of the breathing patterns. The amount of albuterol captured at the mouth opening did not change when the small mask was switched to the large mask, except with the breathing pattern of a child, and when the holes in the mask were 50% occluded (P = .02). Neither decreasing the dead space of the mask nor occluding the mask holes increased the amount of nebulized albuterol captured at the mouth opening.

  17. Individual differences in metacontrast masking regarding sensitivity and response bias.

    Science.gov (United States)

    Albrecht, Thorsten; Mattler, Uwe

    2012-09-01

    In metacontrast masking target visibility is modulated by the time until a masking stimulus appears. The effect of this temporal delay differs across participants in such a way that individual human observers' performance shows distinguishable types of masking functions which remain largely unchanged for months. Here we examined whether individual differences in masking functions depend on different response criteria in addition to differences in discrimination sensitivity. To this end we reanalyzed previously published data and conducted a new experiment for further data analyses. Our analyses demonstrate that a distinction of masking functions based on the type of masking stimulus is superior to a distinction based on the target-mask congruency. Individually different masking functions are based on individual differences in discrimination sensitivities and in response criteria. Results suggest that individual differences in metacontrast masking result from individually different criterion contents. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Design of TOPAZ masking system using EGS4

    International Nuclear Information System (INIS)

    Uno, Shoji

    1991-01-01

    There are two sources of the beam background in the e + e - collider experiments. One source is the synchrotron radiation from many magnets. Another source comes from the spent-electron hitting the beam pipe near the interaction region. To reduce the these background, TOPAZ masking system was designed using EGS4 code. The designed masking system consists of two pairs of masks which are called mask-1 and mask-2. The mask-1 is placed to intercept the spent-electron. The aperture of the mask-2 was determined for the synchrotron radiation photons not to hit the mask-1 directly. After these masks were installed, we are taking the data in the small beam background. (author)

  19. Metacontrast masking is processed before grapheme-color synesthesia.

    Science.gov (United States)

    Bacon, Michael Patrick; Bridgeman, Bruce; Ramachandran, Vilayanur S

    2013-01-01

    We investigated the physiological mechanism of grapheme-color synesthesia using metacontrast masking. A metacontrast target is rendered invisible by a mask that is delayed by about 60 ms; the target and mask do not overlap in space or time. Little masking occurs, however, if the target and mask are simultaneous. This effect must be cortical, because it can be obtained dichoptically. To compare the data for synesthetes and controls, we developed a metacontrast design in which nonsynesthete controls showed weaker dichromatic masking (i.e., the target and mask were in different colors) than monochromatic masking. We accomplished this with an equiluminant target, mask, and background for each observer. If synesthetic color affected metacontrast, synesthetes should show monochromatic masking more similar to the weak dichromatic masking among controls, because synesthetes could add their synesthetic color to the monochromatic condition. The target-mask pairs used for each synesthete were graphemes that elicited strong synesthetic colors. We found stronger monochromatic than dichromatic U-shaped metacontrast for both synesthetes and controls, with optimal masking at an asynchrony of 66 ms. The difference in performance between the monochromatic and dichromatic conditions in the synesthetes indicates that synesthesia occurs at a later processing stage than does metacontrast masking.

  20. Demagnifying electron projection with grid masks

    International Nuclear Information System (INIS)

    Politycki, A.; Meyer, A.

    1978-01-01

    Tightly toleranced micro- and submicrostructures with smooth edges were realized by using transmission masks with an improved supporting grid (width of traverses 0.8 μm). Local edge shift due to the proximity effect is kept at a minimum. Supporting grids with stil narrower traverses (0.5 μm) were prepared by generating the grid pattern by electron beam writing. Masks of this kind allow projection at a demagnification ratio of 1:4, resulting in large image fields. (orig.) [de

  1. The pros and cons of masked priming.

    Science.gov (United States)

    Forster, K I

    1998-03-01

    Masked priming paradigms offer the promise of tapping automatic, strategy-free lexical processing, as evidenced by the lack of expectancy disconfirmation effects, and proportionality effects in semantic priming experiments. But several recent findings suggest the effects may be prelexical. These findings concern nonword priming effects in lexical decision and naming, the effects of mixed-case presentation on nonword priming, and the dependence of priming on the nature of the distractors in lexical decision, suggesting possible strategy effects. The theory underlying each of these effects is discussed, and alternative explanations are developed that do not preclude a lexical basis for masked priming effects.

  2. Robust source and mask optimization compensating for mask topography effects in computational lithography.

    Science.gov (United States)

    Li, Jia; Lam, Edmund Y

    2014-04-21

    Mask topography effects need to be taken into consideration for a more accurate solution of source mask optimization (SMO) in advanced optical lithography. However, rigorous 3D mask models generally involve intensive computation and conventional SMO fails to manipulate the mask-induced undesired phase errors that degrade the usable depth of focus (uDOF) and process yield. In this work, an optimization approach incorporating pupil wavefront aberrations into SMO procedure is developed as an alternative to maximize the uDOF. We first design the pupil wavefront function by adding primary and secondary spherical aberrations through the coefficients of the Zernike polynomials, and then apply the conjugate gradient method to achieve an optimal source-mask pair under the condition of aberrated pupil. We also use a statistical model to determine the Zernike coefficients for the phase control and adjustment. Rigorous simulations of thick masks show that this approach provides compensation for mask topography effects by improving the pattern fidelity and increasing uDOF.

  3. Cosmic Ballet or Devil's Mask?

    Science.gov (United States)

    2004-04-01

    Stars like our Sun are members of galaxies, and most galaxies are themselves members of clusters of galaxies. In these, they move around among each other in a mostly slow and graceful ballet. But every now and then, two or more of the members may get too close for comfort - the movements become hectic, sometimes indeed dramatic, as when galaxies end up colliding. ESO PR Photo 12/04 shows an example of such a cosmic tango. This is the superb triple system NGC 6769-71, located in the southern Pavo constellation (the Peacock) at a distance of 190 million light-years. This composite image was obtained on April 1, 2004, the day of the Fifth Anniversary of ESO's Very Large Telescope (VLT). It was taken in the imaging mode of the VIsible Multi-Object Spectrograph (VIMOS) on Melipal, one of the four 8.2-m Unit Telescopes of the VLT at the Paranal Observatory (Chile). The two upper galaxies, NGC 6769 (upper right) and NGC 6770 (upper left), are of equal brightness and size, while NGC 6771 (below) is about half as bright and slightly smaller. All three galaxies possess a central bulge of similar brightness. They consist of elderly, reddish stars and that of NGC 6771 is remarkable for its "boxy" shape, a rare occurrence among galaxies. Gravitational interaction in a small galaxy group NGC 6769 is a spiral galaxy with very tightly wound spiral arms, while NGC 6770 has two major spiral arms, one of which is rather straight and points towards the outer disc of NGC 6769. NGC 6770 is also peculiar in that it presents two comparatively straight dark lanes and a fainter arc that curves towards the third galaxy, NGC 6771 (below). It is also obvious from this new VLT photo that stars and gas have been stripped off NGC 6769 and NGC 6770, starting to form a common envelope around them, in the shape of a Devil's Mask. There is also a weak hint of a tenuous bridge between NGC 6769 and NGC 6771. All of these features testify to strong gravitational interaction between the three galaxies

  4. Are Masking-Based Models of Risk Useful?

    Science.gov (United States)

    Gisiner, Robert C

    2016-01-01

    As our understanding of directly observable effects from anthropogenic sound exposure has improved, concern about "unobservable" effects such as stress and masking have received greater attention. Equal energy models of masking such as power spectrum models have the appeal of simplicity, but do they offer biologically realistic assessments of the risk of masking? Data relevant to masking such as critical ratios, critical bandwidths, temporal resolution, and directional resolution along with what is known about general mammalian antimasking mechanisms all argue for a much more complicated view of masking when making decisions about the risk of masking inherent in a given anthropogenic sound exposure scenario.

  5. High quality mask storage in an advanced Logic-Fab

    Science.gov (United States)

    Jähnert, Carmen; Fritsche, Silvio

    2012-02-01

    High efficient mask logistics as well as safe and high quality mask storage are essential requirements within an advanced lithography area of a modern logic waferfab. Fast operational availability of the required masks at the exposure tool with excellent mask condition requires a safe mask handling, safeguarding of high mask quality over the whole mask usage time without any quality degradation and an intelligent mask logistics. One big challenge is the prevention of haze on high advanced phase shift masks used in a high volume production line for some thousands of 248nm or 193nm exposures. In 2008 Infineon Dresden qualified a customer specific developed semi-bare mask storage system from DMSDynamic Micro Systems in combination with a high advanced mask handling and an interconnected complex logistic system. This high-capacity mask storage system DMS M1900.22 for more than 3000 masks with fully automated mask and box handling as well as full-blown XCDA purge has been developed and adapted to the Infineon Lithotoollandscape using Nikon and SMIF reticle cases. Advanced features for ESD safety and mask security, mask tracking via RFID and interactions with the exposure tools were developed and implemented. The stocker is remote controlled by the iCADA-RSM system, ordering of the requested mask directly from the affected exposure tool allows fast access. This paper discusses the advantages and challenges for this approach as well as the practical experience gained during the implementation of the new system which improves the fab performance with respect to mask quality, security and throughput. Especially the realization of an extremely low and stable humidity level in addition with a well controlled air flow at each mask surface, preventing masks from haze degradation and particle contamination, turns out to be a notable technical achievement. The longterm stability of haze critical masks has been improved significantly. Relevant environmental parameters like

  6. Antigen smuggling in tuberculosis.

    Science.gov (United States)

    Hudrisier, Denis; Neyrolles, Olivier

    2014-06-11

    The importance of CD4 T lymphocytes in immunity to M. tuberculosis is well established; however, how dendritic cells activate T cells in vivo remains obscure. In this issue of Cell Host & Microbe, Srivastava and Ernst (2014) report a mechanism of antigen transfer for efficient activation of antimycobacterial T cells. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Antigen detection systems

    Science.gov (United States)

    Infectious agents or their constituent parts (antigens or nucleic acids) can be detected in fresh, frozen, or fixed tissues or other specimens, using a variety of direct or indirect assays. The assays can be modified to yield the greatest sensitivity and specificity but in most cases a particular m...

  8. Isocyanate test antigens

    International Nuclear Information System (INIS)

    Karol, M.H.; Alarie, Y.C.

    1980-01-01

    A test antigen for detecting antibodies to a diisocyanate comprises the reaction product of a protein and a monoisocyanate derived from the same radical as the diisocyanate. The diisocyanates most usually encountered and therefore calling for antibody detection are those of toluene, hexamethylene, methylene, isophorone and naphthylene. The preferred protein is human serum albumin. (author)

  9. β-endorphin antigen

    International Nuclear Information System (INIS)

    1981-01-01

    This invention relates to the production of antigens comprising β-endorphin, βsub(h)-endorphin, or βsub(c)-endorphin, in covalent conjugation with human gammaglobulin as immunogenic carrier material, and an antibody having the property of specifically binding β-endorphin or fragments thereof, containing the (6-15) residue sequence. (U.K.)

  10. Evaluation of a new pediatric positive airway pressure mask.

    Science.gov (United States)

    Kushida, Clete A; Halbower, Ann C; Kryger, Meir H; Pelayo, Rafael; Assalone, Valerie; Cardell, Chia-Yu; Huston, Stephanie; Willes, Leslee; Wimms, Alison J; Mendoza, June

    2014-09-15

    The choice and variety of pediatric masks for continuous positive airway pressure (CPAP) is limited in the US. Therefore, clinicians often prescribe modified adult masks. Until recently a mask for children aged mask for children aged 2-7 years (Pixi; ResMed Ltd, Sydney, Australia). Patients aged 2-7 years were enrolled and underwent in-lab baseline polysomnography (PSG) using their previous mask, then used their previous mask and the VPAP III ST-A flow generator for ≥ 10 nights at home. Thereafter, patients switched to the Pixi mask for ≥ 2 nights before returning for a PSG during PAP therapy via the Pixi mask. Patients then used the Pixi mask at home for ≥ 21 nights. Patients and their parents/guardians returned to the clinic for follow-up and provided feedback on the Pixi mask versus their previous mask. AHI with the Pixi mask was 1.1 ± 1.5/h vs 2.6 ± 5.4/h with the previous mask (p = 0.3538). Parents rated the Pixi mask positively for: restfulness of the child's sleep, trouble in getting the child to sleep, and trouble in having the child stay asleep. The Pixi mask was also rated highly for leaving fewer or no marks on the upper lip and under the child's ears, and being easy to remove. The Pixi mask is suitable for children aged 2-7 years and provides an alternative to other masks available for PAP therapy in this age group. © 2014 American Academy of Sleep Medicine.

  11. Micropatterning on cylindrical surfaces via electrochemical etching using laser masking

    International Nuclear Information System (INIS)

    Cho, Chull Hee; Shin, Hong Shik; Chu, Chong Nam

    2014-01-01

    Highlights: • Various micropatterns were fabricated on the cylindrical surface of a stainless steel shaft. • Selective electrochemical dissolution was achieved via a series process of laser masking and electrochemical etching. • Laser masking characteristics on the non-planar surface were investigated. • A uniform mask layer was formed on the cylindrical surface via synchronized laser line scanning with a rotary system. • The characteristics of electrochemical etching on the non-planar surface were investigated. - Abstract: This paper proposes a method of selective electrochemical dissolution on the cylindrical surfaces of stainless steel shafts. Selective electrochemical dissolution was achieved via electrochemical etching using laser masking. A micropatterned recast layer was formed on the surface via ytterbium-doped pulsed fiber laser irradiation. The micropatterned recast layer could be used as a mask layer during the electrochemical etching process. Laser masking condition to form adequate mask layer on the planar surface for etching cannot be used directly on the non-planar surface. Laser masking condition changes depending on the morphological surface. The laser masking characteristics were investigated in order to form a uniform mask layer on the cylindrical surface. To minimize factors causing non-uniformity in the mask layer on the cylindrical surface, synchronized laser line scanning with a rotary system was applied during the laser masking process. Electrochemical etching characteristics were also investigated to achieve deeper etched depth, without collapsing the recast layer. Consequently, through a series process of laser masking and electrochemical etching, various micropatternings were successfully performed on the cylindrical surfaces

  12. Posleslovije k "Zolotoi maske" / Boris Tuch

    Index Scriptorium Estoniae

    Tuch, Boris, 1946-

    2005-01-01

    Vene draamafestivali "Kuldne mask Eestis" lavastusest : "September.doc", lav. Mihhail Ugarov, I. Võrõpajevi "Hapnik" lav. Viktor Rõzhakov Teatr.doc esituses, Sophoklese "Kuningas Oidipus" lav. Andrei Prikotenko Peterburi Teatri Liteinõi esituses, M. Ugarovi lavastus "OblomOFF"

  13. Emergency airway management with laryngeal mask airway

    African Journals Online (AJOL)

    2009-12-01

    Dec 1, 2009 ... management and as a ventilatory device during anesthesia. It is concluded that ... minutes with a tight fitting face mask and a closed system; and 0.6 mg of ... In the operating suite, intravenous access was secured and saline ...

  14. Using excitation patterns to predict auditory masking

    NARCIS (Netherlands)

    Heijden, van der M.L.; Kohlrausch, A.G.

    1992-01-01

    We investigated how well auditory masking can be predicted from excitation patterns. For this purpose, a quantitative model proposed by Moore and Glasberg (1987) and Glasberg and Moore (1990) was used to calculate excitation patterns evoked by stationary sounds. We performed simulations of a number

  15. Central auditory masking by an illusory tone.

    Directory of Open Access Journals (Sweden)

    Christopher J Plack

    Full Text Available Many natural sounds fluctuate over time. The detectability of sounds in a sequence can be reduced by prior stimulation in a process known as forward masking. Forward masking is thought to reflect neural adaptation or neural persistence in the auditory nervous system, but it has been unclear where in the auditory pathway this processing occurs. To address this issue, the present study used a "Huggins pitch" stimulus, the perceptual effects of which depend on central auditory processing. Huggins pitch is an illusory tonal sensation produced when the same noise is presented to the two ears except for a narrow frequency band that is different (decorrelated between the ears. The pitch sensation depends on the combination of the inputs to the two ears, a process that first occurs at the level of the superior olivary complex in the brainstem. Here it is shown that a Huggins pitch stimulus produces more forward masking in the frequency region of the decorrelation than a noise stimulus identical to the Huggins-pitch stimulus except with perfect correlation between the ears. This stimulus has a peripheral neural representation that is identical to that of the Huggins-pitch stimulus. The results show that processing in, or central to, the superior olivary complex can contribute to forward masking in human listeners.

  16. Testing Tactile Masking between the Forearms.

    Science.gov (United States)

    D'Amour, Sarah; Harris, Laurence R

    2016-02-10

    Masking, in which one stimulus affects the detection of another, is a classic technique that has been used in visual, auditory, and tactile research, usually using stimuli that are close together to reveal local interactions. Masking effects have also been demonstrated in which a tactile stimulus alters the perception of a touch at a distant location. Such effects can provide insight into how components of the body's representations in the brain may be linked. Occasional reports have indicated that touches on one hand or forearm can affect tactile sensitivity at corresponding contralateral locations. To explore the matching of corresponding points across the body, we can measure the spatial tuning and effect of posture on contralateral masking. Careful controls are required to rule out direct effects of the remote stimulus, for example by mechanical transmission, and also attention effects in which thresholds may be altered by the participant's attention being drawn away from the stimulus of interest. The use of this technique is beneficial as a behavioural measure for exploring which parts of the body are functionally connected and whether the two sides of the body interact in a somatotopic representation. This manuscript describes a behavioural protocol that can be used for studying contralateral tactile masking.

  17. Software error masking effect on hardware faults

    International Nuclear Information System (INIS)

    Choi, Jong Gyun; Seong, Poong Hyun

    1999-01-01

    Based on the Very High Speed Integrated Circuit (VHSIC) Hardware Description Language (VHDL), in this work, a simulation model for fault injection is developed to estimate the dependability of the digital system in operational phase. We investigated the software masking effect on hardware faults through the single bit-flip and stuck-at-x fault injection into the internal registers of the processor and memory cells. The fault location reaches all registers and memory cells. Fault distribution over locations is randomly chosen based on a uniform probability distribution. Using this model, we have predicted the reliability and masking effect of an application software in a digital system-Interposing Logic System (ILS) in a nuclear power plant. We have considered four the software operational profiles. From the results it was found that the software masking effect on hardware faults should be properly considered for predicting the system dependability accurately in operation phase. It is because the masking effect was formed to have different values according to the operational profile

  18. Shadow mask evaporation through monolayer modified nanostencils

    NARCIS (Netherlands)

    Kolbel, M.; Tjerkstra, R.W.; Brugger, J.P.; van Rijn, C.J.M.; Nijdam, W.; Huskens, Jurriaan; Reinhoudt, David

    2002-01-01

    Gradual clogging of the apertures of nanostencils used as miniature shadow masks in metal evaporations can be reduced by coating the stencil with self-assembled monolayers (SAM). This is quantified by the dimensions (height and volume) of gold features obtained by nanostencil evaporation as measured

  19. Method for coating substrates and mask holder

    NARCIS (Netherlands)

    Bijkerk, Frederik; Yakshin, Andrey; Louis, Eric; Kessels, M.J.H.; Maas, Edward Lambertus Gerardus; Bruineman, Caspar

    2004-01-01

    When coating substrates it is frequently desired that the layer thickness should be a certain function of the position on the substrate to be coated. To control the layer thickness a mask is conventionally arranged between the coating particle source and the substrate. This leads to undesirable

  20. Parallel Implementation of the Terrain Masking Algorithm

    Science.gov (United States)

    1994-03-01

    contains behavior rules which can define a computation or an algorithm. It can communicate with other process nodes, it can contain local data, and it can...terrain maskirg calculation is being performed. It is this algorithm that comsumes about seventy percent of the total terrain masking calculation time

  1. Green binary and phase shifting mask

    Science.gov (United States)

    Shy, S. L.; Hong, Chao-Sin; Wu, Cheng-San; Chen, S. J.; Wu, Hung-Yu; Ting, Yung-Chiang

    2009-12-01

    SixNy/Ni thin film green mask blanks were developed , and are now going to be used to replace general chromium film used for binary mask as well as to replace molydium silicide embedded material for AttPSM for I-line (365 nm), KrF (248 nm), ArF (193 nm) and Contact/Proximity lithography. A bilayer structure of a 1 nm thick opaque, conductive nickel layer and a SixNy layer is proposed for binary and phase-shifting mask. With the good controlling of plasma CVD of SixNy under silane (50 sccm), ammonia (5 sccm) and nitrogen (100 sccm), the pressure is 250 mTorr. and RF frequency 13.56 MHz and power 50 W. SixNy has enough deposition latitude to meet the requirements as an embedded layer for required phase shift 180 degree, and the T% in 193, 248 and 365 nm can be adjusted between 2% to 20% for binary and phase shifting mask usage. Ni can be deposited by E-gun, its sheet resistance Rs is less than 1.435 kΩ/square. Jeol e-beam system and I-line stepper are used to evaluate these thin film green mask blanks, feature size less than 200 nm half pitch pattern and 0.558 μm pitch contact hole can be printed. Transmission spectrums of various thickness of SixNy film are inspected by using UV spectrometer and FTIR. Optical constants of the SixNy film are measured by n & k meter and surface roughness is inspected by using Atomic Force Microscope (AFM).

  2. Summation versus suppression in metacontrast masking: On the potential pitfalls of using metacontrast masking to assess perceptual-motor dissociation.

    Science.gov (United States)

    Cardoso-Leite, Pedro; Waszak, Florian

    2014-07-01

    A briefly flashed target stimulus can become "invisible" when immediately followed by a mask-a phenomenon known as backward masking, which constitutes a major tool in the cognitive sciences. One form of backward masking is termed metacontrast masking. It is generally assumed that in metacontrast masking, the mask suppresses activity on which the conscious perception of the target relies. This assumption biases conclusions when masking is used as a tool-for example, to study the independence between perceptual detection and motor reaction. This is because other models can account for reduced perceptual performance without requiring suppression mechanisms. In this study, we used signal detection theory to test the suppression model against an alternative view of metacontrast masking, referred to as the summation model. This model claims that target- and mask-related activations fuse and that the difficulty in detecting the target results from the difficulty to discriminate this fused response from the response produced by the mask alone. Our data support this alternative view. This study is not a thorough investigation of metacontrast masking. Instead, we wanted to point out that when a different model is used to account for the reduced perceptual performance in metacontrast masking, there is no need to postulate a dissociation between perceptual and motor responses to account for the data. Metacontrast masking, as implemented in the Fehrer-Raab situation, therefore is not a valid method to assess perceptual-motor dissociations.

  3. Oral mask ventilation is more effective than face mask ventilation after nasal surgery.

    Science.gov (United States)

    Yazicioğlu, Dilek; Baran, Ilkay; Uzumcugil, Filiz; Ozturk, Ibrahim; Utebey, Gulten; Sayın, M Murat

    2016-06-01

    To evaluate and compare the face mask (FM) and oral mask (OM) ventilation techniques during anesthesia emergence regarding tidal volume, leak volume, and difficult mask ventilation (DMV) incidence. Prospective, randomized, crossover study. Operating room, training and research hospital. American Society of Anesthesiologists physical status I and II adult patients scheduled for nasal surgery. Patients in group FM-OM received FM ventilation first, followed by OM ventilation, and patients in group OM-FM received OM ventilation first, followed by FM ventilation, with spontaneous ventilation after deep extubation. The FM ventilation was applied with the 1-handed EC-clamp technique. The OM was placed only over the mouth, and the 1-handed EC-clamp technique was used again. A child's size FM was used for the OM ventilation technique, the mask was rotated, and the inferior part of the mask was placed toward the nose. The leak volume (MVleak), mean airway pressure (Pmean), and expired tidal volume (TVe) were assessed with each mask technique for 3 consecutive breaths. A mask ventilation grade ≥3 was considered DMV. DMV occurred more frequently during FM ventilation (75% with FM vs 8% with OM). In the FM-first sequence, the mean TVe was 249±61mL with the FM and 455±35mL with the OM (P=.0001), whereas in the OM-first sequence, it was 276±81mL with the FM and 409±37mL with the OM (P=.0001). Regardless of the order used, the OM technique significantly decreased the MVleak and increased the TVe when compared to the FM technique. During anesthesia emergence after nasal surgery the OM may offer an effective ventilation method as it decreases the incidence of DMV and the gas leak around the mask and provides higher tidal volume delivery compared with FM ventilation. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Nasal mask ventilation is better than face mask ventilation in edentulous patients

    OpenAIRE

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Background and Aims: Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Material and Methods: Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively ev...

  5. Mask_explorer: A tool for exploring brain masks in fMRI group analysis.

    Science.gov (United States)

    Gajdoš, Martin; Mikl, Michal; Mareček, Radek

    2016-10-01

    Functional magnetic resonance imaging (fMRI) studies of the human brain are appearing in increasing numbers, providing interesting information about this complex system. Unique information about healthy and diseased brains is inferred using many types of experiments and analyses. In order to obtain reliable information, it is necessary to conduct consistent experiments with large samples of subjects and to involve statistical methods to confirm or reject any tested hypotheses. Group analysis is performed for all voxels within a group mask, i.e. a common space where all of the involved subjects contribute information. To our knowledge, a user-friendly interface with the ability to visualize subject-specific details in a common analysis space did not yet exist. The purpose of our work is to develop and present such interface. Several pitfalls have to be avoided while preparing fMRI data for group analysis. One such pitfall is spurious non-detection, caused by inferring conclusions in the volume of a group mask that has been corrupted due to a preprocessing failure. We describe a MATLAB toolbox, called the mask_explorer, designed for prevention of this pitfall. The mask_explorer uses a graphical user interface, enables a user-friendly exploration of subject masks and is freely available. It is able to compute subject masks from raw data and create lists of subjects with potentially problematic data. It runs under MATLAB with the widely used SPM toolbox. Moreover, we present several practical examples where the mask_explorer is usefully applied. The mask_explorer is designed to quickly control the quality of the group fMRI analysis volume and to identify specific failures related to preprocessing steps and acquisition. It helps researchers detect subjects with potentially problematic data and consequently enables inspection of the data. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Intervention: Help a Loved One Overcome Addiction

    Science.gov (United States)

    Intervention: Help a loved one overcome addiction An intervention can motivate someone to seek help for alcohol or drug misuse, compulsive eating, or ... successful. By Mayo Clinic Staff It's challenging to help a loved one struggling with any type of ...

  7. Adsorption of multimeric T cell antigens on carbon nanotubes

    DEFF Research Database (Denmark)

    Fadel, Tarek R; Li, Nan; Shah, Smith

    2013-01-01

    Antigen-specific activation of cytotoxic T cells can be enhanced up to three-fold more than soluble controls when using functionalized bundled carbon nanotube substrates ((b) CNTs). To overcome the denaturing effects of direct adsorption on (b) CNTs, a simple but robust method is demonstrated...... to stabilize the T cell stimulus on carbon nanotube substrates through non-covalent attachment of the linker neutravidin....

  8. Scatterometry on pelliclized masks: an option for wafer fabs

    Science.gov (United States)

    Gallagher, Emily; Benson, Craig; Higuchi, Masaru; Okumoto, Yasuhiro; Kwon, Michael; Yedur, Sanjay; Li, Shifang; Lee, Sangbong; Tabet, Milad

    2007-03-01

    Optical scatterometry-based metrology is now widely used in wafer fabs for lithography, etch, and CMP applications. This acceptance of a new metrology method occurred despite the abundance of wellestablished CD-SEM and AFM methods. It was driven by the desire to make measurements faster and with a lower cost of ownership. Over the last year, scatterometry has also been introduced in advanced mask shops for mask measurements. Binary and phase shift masks have been successfully measured at all desired points during photomask production before the pellicle is mounted. There is a significant benefit to measuring masks with the pellicle in place. From the wafer fab's perspective, through-pellicle metrology would verify mask effects on the same features that are characterized on wafer. On-site mask verification would enable quality control and trouble-shooting without returning the mask to a mask house. Another potential application is monitoring changes to mask films once the mask has been delivered to the fab (haze, oxide growth, etc.). Similar opportunities apply to the mask metrologist receiving line returns from a wafer fab. The ability to make line-return measurements without risking defect introduction is clearly attractive. This paper will evaluate the feasibility of collecting scatterometry data on pelliclized masks. We explore the effects of several different pellicle types on scatterometry measurements made with broadband light in the range of 320-780 nm. The complexity introduced by the pellicles' optical behavior will be studied.

  9. Comparison of monaural (CMR) and binaural (BMLD) masking release

    NARCIS (Netherlands)

    Par, van de S.L.J.D.E.; Kohlrausch, A.G.

    1998-01-01

    Release of masking for a sinusoidal signal of 5 kHz masked by a 25-Hz-wide noise band centered around 5 kHz was measured. The masking release was provided by a second noise band that was comodulated with the on-frequency masker band. For CMR configurations the second noise band was centered at 3 kHz

  10. 21 CFR 868.5550 - Anesthetic gas mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthetic gas mask. 868.5550 Section 868.5550...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5550 Anesthetic gas mask. (a) Identification. An anesthetic gas mask is a device, usually made of conductive rubber, that is positioned over a...

  11. New Chimeric Antigen Receptor Design for Solid Tumors

    Directory of Open Access Journals (Sweden)

    Yuedi Wang

    2017-12-01

    Full Text Available In recent years, chimeric antigen receptor (CAR T-cell therapy has become popular in immunotherapy, particularly after its tremendous success in the treatment of lineage-restricted hematologic cancers. However, the application of CAR T-cell therapy for solid tumors has not reached its full potential because of the lack of specific tumor antigens and inhibitory factors in suppressive tumor microenvironment (TME (e.g., programmed death ligand-1, myeloid-derived suppressor cells, and transforming growth factor-β. In this review, we include some limitations in CAR design, such as tumor heterogeneity, indefinite spatial distance between CAR T-cell and its target cell, and suppressive TME. We also summarize some new approaches to overcome these hurdles, including targeting neoantigens and/or multiple antigens at once and depleting some inhibitory factors.

  12. Contrast Gain Control Model Fits Masking Data

    Science.gov (United States)

    Watson, Andrew B.; Solomon, Joshua A.; Null, Cynthia H. (Technical Monitor)

    1994-01-01

    We studied the fit of a contrast gain control model to data of Foley (JOSA 1994), consisting of thresholds for a Gabor patch masked by gratings of various orientations, or by compounds of two orientations. Our general model includes models of Foley and Teo & Heeger (IEEE 1994). Our specific model used a bank of Gabor filters with octave bandwidths at 8 orientations. Excitatory and inhibitory nonlinearities were power functions with exponents of 2.4 and 2. Inhibitory pooling was broad in orientation, but narrow in spatial frequency and space. Minkowski pooling used an exponent of 4. All of the data for observer KMF were well fit by the model. We have developed a contrast gain control model that fits masking data. Unlike Foley's, our model accepts images as inputs. Unlike Teo & Heeger's, our model did not require multiple channels for different dynamic ranges.

  13. Multi-part mask for implanting workpieces

    Science.gov (United States)

    Webb, Aaron P.; Carlson, Charles T.

    2016-05-10

    A multi-part mask has a pattern plate, which includes a planar portion that has the desired aperture pattern to be used during workpiece processing. The multi-part mask also has a mounting frame, which is used to hold the pattern plate. Prior to assembly, the pattern plate has an aligning portion, which has one or more holes through which reusable alignment pins are inserted. These alignment pins enter kinematic joints disposed on the mounting frame, which serve to precisely align the pattern plate to the mounting frame. After the pattern plate has been secured to the mounting frame, the aligning portion can be detached from the pattern plate. The alignment pins can be reused at a later time. In some embodiments, the pattern plate can later be removed from the mounting frame, so that the mounting frame may be reused.

  14. Negative ion source improvement by introduction of a shutter mask

    International Nuclear Information System (INIS)

    Belchenko, Yu.I.; Oka, Y.; Kaneko, O.; Takeiri, Y.; Tsumori, K.; Osakabe, M.; Ikeda, K.; Asano, E.; Kawamoto, T.

    2004-01-01

    Studies of a multicusp source were recently done at the National Institute for Fusion Science by plasma grid masking. The maximal H - ion yield is ∼1.4 times greater for the shutter mask case than that for the standard source. Negative ion current evolution during the cesium feed to the masked plasma grid evidenced that about 60% of negative ions are produced on the shutter mask surface, while about 30% are formed on the plasma grid emission hole edges, exposed by cesium with the mask open

  15. Deteksi Antigen pada Kriptokokosis

    Directory of Open Access Journals (Sweden)

    Robiatul Adawiyah

    2014-12-01

    Full Text Available AbstrakKriptokokosis merupakan infeksi sistemik yang disebabkan Cryptococcus sp. Predileksi jamur tersebut adalah susunan saraf pusat dan selaput otak. Terdapat 5 spesies Cryptococcus sp. yang menyebabkan penyakit pada manusia; yang paling banyak adalah Cr. neoformans dan Cr. gattii. Diagnosis kriptokokosis ditegakkan berdasarkan gejala klinis, pemeriksaan laboratoris serta radiologis. Pemeriksaan laboratoris dilakukan dengan identifikasi morfologi, serologi danPCR. Pemeriksaan secara morfologi dengan tinta India positif  bila jumlah sel jamur 10  sel/ml spesimen. Kultur dilakukan di media sabouraud dextrose agar (SDA dan niger sheed agar (NSA, jamur tumbuh setelah 5-7 hari. Deteksi antigen dan antibodi dilakukan pada cairan tubuh dan tidak membutuhkan waktu lama. Deteksi antibodi Cr.neoformans memiliki kelemahan yaitu tidak menunjukkan hasil positif pada infeksi akut, IgA masih positif setelah 1-2 tahun fase penyembuhan, IgG dapat persisten, pada individu imunokompromis menunjukkan hasil yang sangat kompleks dan dalam menentukan diagnosis sering tidak konsisten. Polisakarida adalah komponen paling berperan dalam virulensi Cr. neoformans. Komponen polisakarida terutama glucuronoxylomannan merupakan petanda penting dalam diagnosis kriptokokosis secara serologis. Deteksi antigen Cr. neoformans memiliki kelebihan yaitu menunjukkan hasil positif pada infeksi akut/kronis, sensitivitas dan spesifisitas tinggi, dapat mendeteksi polisakarida hingga 10 ng/ml sehingga dengan kadarantigen yang minimal tetap dapat mendiagnosis kriptokokosis.Kata kunci: Cr. neoformans, glucuronoxylomannan, antigenAbstractCryptococcosis is systemic infection that caused by Cryptococcus sp. Predilection of this fungi is the central nervous system and brain membrane. There are 5 species of Cryptococcus sp. that cause cryptococcosis in human; but the majority are caused by Cr. neoformans and Cr. gattii. The diagnosis of cryptococcosis is made based on clinical symptoms

  16. [Patients' reaction to pharmacists wearing a mask during their consultations].

    Science.gov (United States)

    Tamura, Eri; Kishimoto, Keiko; Fukushima, Noriko

    2013-01-01

      This study sought to determine the effect of pharmacists wearing a mask on the consultation intention of patients who do not have a trusting relationship with the pharmacists. We conducted a questionnaire survey of customers at a Tokyo drugstore in August 2012. Subjects answered a questionnaire after watching two medical teaching videos, one in which the pharmacist was wearing a mask and the other in which the pharmacist was not wearing a mask. Data analysis was performed using a paired t-test and multiple logistic regression. The paired t-test revealed a significant difference in 'Maintenance Problem' between the two pharmacist situations. After excluding factors not associated with wearing a mask, multiple logistic regression analysis identified three independent variables with a significant effect on participants not wanting to consult with a pharmacist wearing a mask. Positive factors were 'active-inactive' and 'frequency mask use', a negative factor was 'age'. Our study has shown that pharmacists wearing a mask may be a factor that prevents patients from consulting with pharmacist. Those patients whose intention to consult might be affected by the pharmacists wearing a mask tended to be younger, to have no habit of wearing masks preventively themselves, and to form a negative opinion of such pharmacists. Therefore, it was estimated that pharmacists who wear masks need to provide medical education by asking questions more positively than when they do not wear a mask in order to prevent the patient worrying about oneself.

  17. Contact printed masks for 3D microfabrication in negative resists

    DEFF Research Database (Denmark)

    Häfliger, Daniel; Boisen, Anja

    2005-01-01

    We present a process based on contact printed shadow masks for three dimensional microfabrication of soft and sensitive overhanging membranes in SU-8. A metal mask is transferred onto unexposed SU-8 from an elastomer stamp made of polydimethylsiloxane. This mask is subsequently embedded into the ......We present a process based on contact printed shadow masks for three dimensional microfabrication of soft and sensitive overhanging membranes in SU-8. A metal mask is transferred onto unexposed SU-8 from an elastomer stamp made of polydimethylsiloxane. This mask is subsequently embedded...... into the negative resist to protect buried material from UV-exposure. Unlike direct evaporation-deposition of a mask onto the SU-8, printing avoids high stress and radiation, thus preventing resist wrinkling and prepolymerization. We demonstrate effective monolithic fabrication of soft, 4-μm thick and 100-μm long...

  18. The effect of masking in the attentional dwell time paradigm

    DEFF Research Database (Denmark)

    Petersen, Anders

    2009-01-01

    , 1994). In most studies of attentional dwell time, two masked targets have been used. Moore et al. (1996) have criticised the masking of the first target when measuring the attentional dwell time, finding a shorter attentional dwell time when the first mask was omitted. In the presented work, the effect...... of the first mask is further investigated by including a condition where the first mask is presented without a target. The results from individual subjects show that the findings of Moore et al. can be replicated. The results also suggest that presenting the first mask without a target is enough to produce...... an impairment of the second target. Hence, the attentional dwell time may be a combined effect arising from attending to both the first target and its mask....

  19. APPLICATION OF EQUIPMENT FOR AUTOMATIC CONTROL OF PLANAR STRUCTURES IN MANUFACTURING MASTER MASKS OF INTEGRATED CIRCUITS ON PHOTO-MASKS

    Directory of Open Access Journals (Sweden)

    S. M. Avakov

    2007-01-01

    Full Text Available Following the concept of defect-free manufacturing of master masks of IC on photo-masks, two Belarusian sets of optomechanical equipment for 0,3 5 p and 90 nanometers are presented in the paper. Each of the sets comprises:   • Multi-channel laser pattern generator; • Automatic mask defect inspection system; • Laser-based mask defect repair system.The paper contains description of automatic mask defect inspection process during photo-mask manufacturing and respective basic technological operations of the processes.Advantages of a complex approach to the development of a set of opto-mechanical equipment for defect-free manufacturing of photo-masks have been analyzed in the paper. 

  20. Carcino-Embryonic Antigen

    International Nuclear Information System (INIS)

    Akute, O.

    1999-02-01

    Tumour marker analysis has increased our understanding of the presence of tumours in the body. Carcino-embryonic antigen, CEA, is one of the best studied tumour markers and has proved an ideal diagnostic adjuvant. It has helped in quantifying the amount of disease present in a patient and thence to make accurate prognosis on the various diagnosed ailments. At UCH, it is observed that there is an increase in cancer related ailments and therefore the need for early diagnosis is more compelling in our environment to mitigate future cost of managing advanced manifestation

  1. Mask ventilation with two different face masks in the delivery room for preterm infants: a randomized controlled trial.

    Science.gov (United States)

    Cheung, D; Mian, Q; Cheung, P-Y; O'Reilly, M; Aziz, K; van Os, S; Pichler, G; Schmölzer, G M

    2015-07-01

    If an infant fails to initiate spontaneous breathing after birth, international guidelines recommend a positive pressure ventilation (PPV). However, PPV by face mask is frequently inadequate because of leak between the face and mask. Despite a variety of available face masks, none have been prospectively compared in a randomized fashion. We aimed to evaluate and compare leak between two commercially available round face masks (Fisher & Paykel (F&P) and Laerdal) in preterm infants mask PPV in the delivery room routinely had a flow sensor placed between the mask and T-piece resuscitator. Infants were randomly assigned to receive PPV with either a F&P or Laerdal face mask. All resuscitators were trained in the use of both face masks. We compared mask leak, airway pressures, tidal volume and ventilation rate between the two groups. Fifty-six preterm infants (n=28 in each group) were enrolled; mean±s.d. gestational age 28±3 weeks; birth weight 1210±448 g; and 30 (52%) were male. Apgar scores at 1 and 5 min were 5±3 and 7±2, respectively. Infants randomized to the F&P face mask and Laerdal face mask had similar mask leak (30 (25-38) versus 35 (24-46)%, median (interquartile range), respectively, P=0.40) and tidal volume (7.1 (4.9-8.9) versus 6.6 (5.2-8.9) ml kg(-1), P=0.69) during PPV. There were no significant differences in ventilation rate, inflation time or airway pressures between groups. The use of either face mask during PPV in the delivery room yields similar mask leak in preterm infants <33 weeks gestational age.

  2. Noninvasive CPAP with face mask: comparison among new air-entrainment masks and the Boussignac valve.

    Science.gov (United States)

    Mistraletti, Giovanni; Giacomini, Matteo; Sabbatini, Giovanni; Pinciroli, Riccardo; Mantovani, Elena S; Umbrello, Michele; Palmisano, Debora; Formenti, Paolo; Destrebecq, Anne L L; Iapichino, Gaetano

    2013-02-01

    The performances of 2 noninvasive CPAP systems (high flow and low flow air-entrainment masks) were compared to the Boussignac valve in 3 different scenarios. Scenario 1: pneumatic lung simulator with a tachypnea pattern (tidal volume 800 mL at 40 breaths/min). Scenario 2: Ten healthy subjects studied during tidal breaths and tachypnea. Scenario 3: Twenty ICU subjects enrolled for a noninvasive CPAP session. Differences between set and effective CPAP level and F(IO(2)), as well as the lowest airway pressure and the pressure swing around the imposed CPAP level, were analyzed. The lowest airway pressure and swing were correlated to the pressure-time product (area of the airway pressure curve below the CPAP level) measured with the simulator. P(aO(2)) was a subject's further performance index. Lung simulator: Boussignac F(IO(2)) was 0.54, even if supplied with pure oxygen. The air-entrainment masks had higher swing than the Boussignac (P = .007). Pressure-time product correlated better with pressure swing (Spearman correlation coefficient [ρ] = 0.97) than with lowest airway pressure (ρ = 0.92). In healthy subjects, the high-flow air-entrainment mask showed lower difference between set and effective F(IO(2)) (P mask had lower swing than the Boussignac valve (P = .03) with similar P(aO(2)) increase. High-flow air-entrainment mask showed the best performance in human subjects. During high flow demand, the Boussignac valve delivered lower than expected F(IO(2)) and showed higher dynamic hyper-pressurization than the air-entrainment masks. © 2013 Daedalus Enterprises.

  3. Is tinnitus an early voice of masked hypertension? High masked hypertension rate in patients with tinnitus.

    Science.gov (United States)

    Gun, Taylan; Özkan, Selçuk; Yavuz, Bunyamin

    2018-04-23

    Tinnitus is hearing a sound without any external acoustic stimulus. There are some clues of hypertension can cause tinnitus in different ways. The aim of the study was to evaluate the relationship between tinnitus and masked hypertension including echocardiographic parameters and severity of tinnitus. This study included 88 patients with tinnitus of at least 3 months duration and 85 age and gender-matched control subjects. Tinnitus severity index was used to classify the patients with tinnitus. After a complete medical history, all subjects underwent routine laboratory examination, office blood pressure measurement, hearing tests and ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of masked hypertension was significantly higher in patients with tinnitus than controls (18.2% vs 3.5%, p = 0.002). Office diastolic BP (76 ± 8.1 vs. 72.74 ± 8.68, p = 0.01), ambulatory 24-H diastolic BP (70.2 ± 9.6 vs. 66.9 ± 6.1, p = 0.07) and ambulatory daytime diastolic BP (73.7 ± 9.5 vs. 71.1 ± 6.2, p = 0.03) was significantly higher in patients with tinnitus than control group. Tinnitus severity index in patients without masked hypertension was 0 and tinnitus severity index in patients with masked hypertension were 2 (1-5). This study demonstrated that masked hypertension must be kept in mind if there is a complaint of tinnitus without any other obvious reason.

  4. Causal mechanisms of masked hypertension: socio-psychological aspects.

    Science.gov (United States)

    Ogedegbe, Gbenga

    2010-04-01

    The contribution of Dr Thomas Pickering's study to the measurement of blood pressure (BP) is the defining aspect of his academic career and achievement - narrowly defined. In this regard, two important areas characterized his study as it relates to masked hypertension. First, he introduced the term, masked hypertension, to replace the rather inappropriate term 'reverse white-coat hypertension' and 'white-coat normotension'; thus drawing attention to the fact that these patients are genuinely hypertensive by ambulatory BP but were missed by normal office BP. More importantly, he rightly maintained that masked hypertension is a true continuum of sustained hypertension rather than an aberrant measurement artifact. Second, is his pivotal study on the important role of psychosocial factors as a potential mechanism for the development of masked hypertension. In this regard, he explained masked hypertension as a conditioned response to anxiety in office settings, and highlighted the role that diagnostic labeling plays in its development. His view of masked hypertension is that of a continuum from prehypertension (based on office BP measurement) to masked hypertension (based on ambulatory BP) and finally to sustained hypertension (based on both office and ambulatory BP). He strongly believes that it is the prehypertensive patients who progress to masked hypertension. Subsequently, patients who are prehypertensive should be screened for masked hypertension and treated. In this manuscript, we summarize his study as it relates to the definition of masked hypertension, the psychosocial characteristics, mechanisms and its clinical relevance.

  5. Investigating neurophysiological correlates of metacontrast masking with magnetoencephalography

    Directory of Open Access Journals (Sweden)

    Jens Schwarzbach

    2006-01-01

    Full Text Available Early components of visual evoked potentials (VEP in EEG seem to be unaffected by target visibility in visual masking studies. Bridgeman's reanalysis of Jeffreys and Musselwhite's (1986 data suggests that a later visual component in the VEP, around 250 ms reflects the perceptual effect of masking. We challenge this view on the ground that temporal interactions between targets and masks unrelated to stimulus visibility could account for Bridgeman's observation of a U-shaped time course in VEP amplitudes for this later component. In an MEG experiment of metacontrast masking with variable stimulus onset asynchrony, we introduce a proper control, a pseudo mask. In contrast to an effective mask, the pseudomask should produce neither behavioral masking nor amplitude modulations of late VEPs. Our results show that effective masks produced a strong U-shaped perceptual effect of target visibility while performance remained virtually perfect when a pseudomask was used. The visual components around 250 ms after target onset did not show a distinction between mask and pseudomask conditions. The results indicate that these visual evoked potentials do not reveal neurophysiological correlates of stimulus visibility but rather reflect dynamic interactions between superimposed potentials elicited by stimuli in close temporal proximity. However, we observed a postperceptual component around 340 ms after target onset, located over temporal-parietal cortex, which shows a clear effect of visibility. Based on P300 ERP literature, this finding could indicate that working memory related processes contribute to metacontrast masking.

  6. Learning communities and overcoming poverty in Brazil

    Directory of Open Access Journals (Sweden)

    Tatiana Santos Pitanga

    2015-09-01

    Full Text Available Object: Brazil has implemented social programs to meet the Millennium Development Goals of reducing poverty and inequality. Despite the good results still there are ghettos and educational and social inequalities. Moreover Learning Communities are responding to these needs by promoting education based on successful actions scientifically proven of which promote educational change and social inclusion. The aim of this article is to highlight the characteristics of Learning Communities that allow overcoming poverty, and in this perspective, explain the implementation of the Learning Communities in Brazil and how, in this way, it is creating the conditions for effective overcoming give poverty and inequality in this country.Design / methodology: This article is based on documentary analysis of reports of the INCLUD-ED - the project on school education more scientific resources has been funded by the European Union, United Nations / ECLAC, Brazilian public agencies and websites of official institutions that promote Learning Communities in Brazil. Brazilian Institute of Geography and Statistics are also collected.Contributions and results: It highlights successful actions that contribute to overcoming poverty and social exclusion. Such actions are based on dialogic learning, democratic management and the formation of heterogeneous groups. It is observed that in Brazil are carrying out such actions and the ongoing expansion of the project in the country is creating the conditions for effective poverty reduction.Added value: This article reveals specific elements of overcoming poverty through education.

  7. Overcoming Learned Helplessness in Community College Students.

    Science.gov (United States)

    Roueche, John E.; Mink, Oscar G.

    1982-01-01

    Reviews research on the effects of repeated experiences of helplessness and on locus of control. Identifies conditions necessary for overcoming learned helplessness; i.e., the potential for learning to occur; consistent reinforcement; relevant, valued reinforcers; and favorable psychological situation. Recommends eight ways for teachers to…

  8. Learn to Avoid or Overcome Leadership Obstacles

    Science.gov (United States)

    D'Auria, John

    2015-01-01

    Leadership is increasingly recognized as an important factor in moving schools forward, yet we have been relatively random in how we prepare and support them. Four obstacles often block or diminish their effectiveness. Avoiding or overcoming each of these requires an underlying set of skills and knowledge that we believe can be learned and…

  9. Overcoming Barriers in Working with Families

    Science.gov (United States)

    Heru, Alison M.; Drury, Laura

    2006-01-01

    Objective: The Accreditation Council for Graduate Medical Education and the Residency Review Committee for psychiatry outline the expected competencies for residents. These competencies include working with families. This article describes barriers that residents face when working with families, and offers ways to overcome these barriers. Method:…

  10. Successful Writing: Five Roadblocks to Overcome

    Science.gov (United States)

    King, Kathleen P.

    2013-01-01

    This article provides essential strategies to be more successful in one of the major roles in academia: writing. Most academics struggle with roadblocks in their writing process. We are forever battling to complete research articles, manuscripts, grant proposals or other documents. The strategies and perspective shared here help overcome several…

  11. Silicon germanium mask for deep silicon etching

    KAUST Repository

    Serry, Mohamed

    2014-07-29

    Polycrystalline silicon germanium (SiGe) can offer excellent etch selectivity to silicon during cryogenic deep reactive ion etching in an SF.sub.6/O.sub.2 plasma. Etch selectivity of over 800:1 (Si:SiGe) may be achieved at etch temperatures from -80 degrees Celsius to -140 degrees Celsius. High aspect ratio structures with high resolution may be patterned into Si substrates using SiGe as a hard mask layer for construction of microelectromechanical systems (MEMS) devices and semiconductor devices.

  12. Silicon germanium mask for deep silicon etching

    KAUST Repository

    Serry, Mohamed; Rubin, Andrew; Refaat, Mohamed; Sedky, Sherif; Abdo, Mohammad

    2014-01-01

    Polycrystalline silicon germanium (SiGe) can offer excellent etch selectivity to silicon during cryogenic deep reactive ion etching in an SF.sub.6/O.sub.2 plasma. Etch selectivity of over 800:1 (Si:SiGe) may be achieved at etch temperatures from -80 degrees Celsius to -140 degrees Celsius. High aspect ratio structures with high resolution may be patterned into Si substrates using SiGe as a hard mask layer for construction of microelectromechanical systems (MEMS) devices and semiconductor devices.

  13. Model-based virtual VSB mask writer verification for efficient mask error checking and optimization prior to MDP

    Science.gov (United States)

    Pack, Robert C.; Standiford, Keith; Lukanc, Todd; Ning, Guo Xiang; Verma, Piyush; Batarseh, Fadi; Chua, Gek Soon; Fujimura, Akira; Pang, Linyong

    2014-10-01

    A methodology is described wherein a calibrated model-based `Virtual' Variable Shaped Beam (VSB) mask writer process simulator is used to accurately verify complex Optical Proximity Correction (OPC) and Inverse Lithography Technology (ILT) mask designs prior to Mask Data Preparation (MDP) and mask fabrication. This type of verification addresses physical effects which occur in mask writing that may impact lithographic printing fidelity and variability. The work described here is motivated by requirements for extreme accuracy and control of variations for today's most demanding IC products. These extreme demands necessitate careful and detailed analysis of all potential sources of uncompensated error or variation and extreme control of these at each stage of the integrated OPC/ MDP/ Mask/ silicon lithography flow. The important potential sources of variation we focus on here originate on the basis of VSB mask writer physics and other errors inherent in the mask writing process. The deposited electron beam dose distribution may be examined in a manner similar to optical lithography aerial image analysis and image edge log-slope analysis. This approach enables one to catch, grade, and mitigate problems early and thus reduce the likelihood for costly long-loop iterations between OPC, MDP, and wafer fabrication flows. It moreover describes how to detect regions of a layout or mask where hotspots may occur or where the robustness to intrinsic variations may be improved by modification to the OPC, choice of mask technology, or by judicious design of VSB shots and dose assignment.

  14. Mask manufacturing improvement through capability definition and bottleneck line management

    Science.gov (United States)

    Strott, Al

    1994-02-01

    In 1989, Intel's internal mask operation limited itself to research and development activities and re-inspection and pellicle application of externally manufactured masks. Recognizing the rising capital cost of mask manufacturing at the leading edge, Intel's Mask Operation management decided to offset some of these costs by manufacturing more masks internally. This was the beginning of the challenge they set to manufacture at least 50% of Intel's mask volume internally, at world class performance levels. The first step in responding to this challenge was the completion of a comprehensive operation capability analysis. A series of bottleneck improvements by focus teams resulted in an average cycle time improvement to less than five days on all product and less than two days on critical products.

  15. Random mask optimization for fast neutron coded aperture imaging

    Energy Technology Data Exchange (ETDEWEB)

    McMillan, Kyle [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Univ. of California, Los Angeles, CA (United States); Marleau, Peter [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Brubaker, Erik [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-05-01

    In coded aperture imaging, one of the most important factors determining the quality of reconstructed images is the choice of mask/aperture pattern. In many applications, uniformly redundant arrays (URAs) are widely accepted as the optimal mask pattern. Under ideal conditions, thin and highly opaque masks, URA patterns are mathematically constructed to provide artifact-free reconstruction however, the number of URAs for a chosen number of mask elements is limited and when highly penetrating particles such as fast neutrons and high-energy gamma-rays are being imaged, the optimum is seldom achieved. In this case more robust mask patterns that provide better reconstructed image quality may exist. Through the use of heuristic optimization methods and maximum likelihood expectation maximization (MLEM) image reconstruction, we show that for both point and extended neutron sources a random mask pattern can be optimized to provide better image quality than that of a URA.

  16. An investigation into the efficiency of disposable face masks.

    Science.gov (United States)

    Rogers, K B

    1980-01-01

    Disposable face masks used in hospitals have been assessed for the protection afforded the patient and the wearer by challenges of simulated natural conditions of stress. Operating theatre masks made of synthetic materials allow the wearer to breathe through the masks, and these have been shown to protect the patient well but the wearer slightly less. Cheaper paper masks are worn for ward duties, and of these only the Promask protected in area in front of the wearer: air does not pass through this mask, expired air is prevented from passing forward, and the wearer breathes unfiltered air. All the other paper masks tested allowed many bacteria-laden particles to pass through them. PMID:7440756

  17. Joint optimization of source, mask, and pupil in optical lithography

    Science.gov (United States)

    Li, Jia; Lam, Edmund Y.

    2014-03-01

    Mask topography effects need to be taken into consideration for more advanced resolution enhancement techniques in optical lithography. However, rigorous 3D mask model achieves high accuracy at a large computational cost. This work develops a combined source, mask and pupil optimization (SMPO) approach by taking advantage of the fact that pupil phase manipulation is capable of partially compensating for mask topography effects. We first design the pupil wavefront function by incorporating primary and secondary spherical aberration through the coefficients of the Zernike polynomials, and achieve optimal source-mask pair under the condition of aberrated pupil. Evaluations against conventional source mask optimization (SMO) without incorporating pupil aberrations show that SMPO provides improved performance in terms of pattern fidelity and process window sizes.

  18. Effects of mask imperfections on InP etching profiles

    International Nuclear Information System (INIS)

    Huo, D.T.C.; Yan, M.F.; Wynn, J.D.; Wilt, D.P.

    1990-01-01

    The authors have demonstrated that the quality of etch masks has a significant effect on the InP etching profiles. In particular, the authors have shown that mask imperfections can cause defective etching profiles, such as vertical sidewalls and extra mask undercutting in InP. The authors also discovered that the geometry of these defective profiles is determined by the orientation of the substrate relative to the direction of the mask imperfections. Along a left-angle 110 right-angle line mask defect, the downward etching process changes the left-angle 110 right-angle v-grooves to vertical sidewalls without extra undercutting. For v-grooves aligned along the left-angle 110 right-angle direction, defects on the mask give a significant extra undercutting without changing the etching profile

  19. Characterizing the monaural and binaural processes underlying reflection masking

    DEFF Research Database (Denmark)

    Buchholz, Jörg

    2007-01-01

    for the two RMTs, it is shown that forward masking effects only have a significant effect on reflection masking for delays above 7–10 ms. Moreover, binaural mechanisms were revealed which deteriorate auditory detection of test reflections for delays below 7–10 ms and enhance detection for larger delays....... The monaural and binaural processes that may underlie reflection masking are discussed in terms of auditory-modelling concepts....

  20. Antigen antibody interactions

    CERN Document Server

    DeLisi, Charles

    1976-01-01

    1. 1 Organization of the Immune System One of the most important survival mechanisms of vertebrates is their ability to recognize and respond to the onslaught of pathogenic microbes to which they are conti- ously exposed. The collection of host cells and molecules involved in this recognition­ 12 response function constitutes its immune system. In man, it comprises about 10 cells 20 (lymphocytes) and 10 molecules (immunoglobulins). Its ontogenic development is c- strained by the requirement that it be capable of responding to an almost limitless variety of molecular configurations on foreign substances, while simultaneously remaining inert to those on self components. It has thus evolved to discriminate, with exquisite precision, between molecular patterns. The foreign substances which induce a response, called antigens, are typically large molecules such as proteins and polysaccharides. The portions of these with which immunoglobulins interact are called epitopes or determinants. A typical protein epitope m...

  1. Tachistoscopic illumination and masking of real scenes.

    Science.gov (United States)

    Chichka, David; Philbeck, John W; Gajewski, Daniel A

    2015-03-01

    Tachistoscopic presentation of scenes has been valuable for studying the emerging properties of visual scene representations. The spatial aspects of this work have generally been focused on the conceptual locations (e.g., next to the refrigerator) and directional locations of objects in 2-D arrays and/or images. Less is known about how the perceived egocentric distance of objects develops. Here we describe a novel system for presenting brief glimpses of a real-world environment, followed by a mask. The system includes projectors with mechanical shutters for projecting the fixation and masking images, a set of LED floodlights for illuminating the environment, and computer-controlled electronics to set the timing and initiate the process. Because a real environment is used, most visual distance and depth cues can be manipulated using traditional methods. The system is inexpensive, robust, and its components are readily available in the marketplace. This article describes the system and the timing characteristics of each component. We verified the system's ability to control exposure to time scales as low as a few milliseconds.

  2. The performances of standard and ResMed masks during bag-valve-mask ventilation.

    Science.gov (United States)

    Lee, Hyoung Youn; Jeung, Kyung Woon; Lee, Byung Kook; Lee, Seung Joon; Jung, Yong Hun; Lee, Geo Sung; Min, Yong Il; Heo, Tag

    2013-01-01

    A tight mask seal is frequently difficult to obtain and maintain during single-rescuer bag-valve-mask (BVM) ventilation. The ResMed mask (Bella Vista, NSW, Australia) is a continuous-positive-airway-pressure mask (CM) designed for noninvasive ventilation. In this study, we compared the ventilation performances of a standard mask (SM) and a ResMed CM using a simulation manikin in an out-of-hospital single-rescuer BVM ventilation scenario. Thirty emergency medical technicians (EMTs) performed two 2-minute attempts to ventilate a simulation manikin using BVM ventilation, alternatively, with the SM or the ResMed CM in a randomized order. Ventilation parameters including tidal volume and peak airway pressure were measured using computer analysis software connected to the simulation manikin. Successful volume delivery was defined as delivery of 440-540 mL of tidal volume in accord with present cardiopulmonary resuscitation guidelines. BVM ventilation using the ResMed CM produced higher mean (± standard deviation) tidal volumes (452 ± 50 mL vs. 394 ± 113 mL, p = 0.014) and had a higher proportion of successful volume deliveries (65.3% vs. 26.7%, p < 0.001) than that using the SM. Peak airway pressure was higher in BVM ventilation using the ResMed CM (p = 0.035). Stomach insufflation did not occur during either method. Twenty-nine of the participants (96.7%) preferred BVM ventilation using the ResMed CM. BVM ventilations using ResMed CM resulted in a significantly higher proportion of successful volume deliveries meeting the currently recommended range of tidal volume. Clinical studies are needed to determine the value of the ResMed CM for BVM ventilation.

  3. Mechanical and thermal modeling of the SCALPEL mask

    International Nuclear Information System (INIS)

    Martin, C. J.; Semke, W. H.; Dicks, G. A.; Engelstad, R. L.; Lovell, E. G.; Liddle, J. A.; Novembre, A. E.

    1999-01-01

    Scattering with angular limitation projection electron-beam lithography (SCALPEL) is being developed by Lucent Technologies for sub-130 nm lithography. The mask fabrication and exposure processes produce mask distortions that result in pattern placement errors. In order to understand these distortions, and determine how to reduce them to levels consistent with the error budget, structural and heat transfer finite element models have been generated to simulate the mechanical and thermal response of the mask. In addition, sensitivity studies of the distortions due to key design parameters that may be used to refine the SCALPEL mask configuration have been conducted. (c) 1999 American Vacuum Society

  4. A respiratory mask for resting and exercising dogs.

    Science.gov (United States)

    Stavert, D M; Reischl, P; O'Loughlin, B J

    1982-02-01

    A respiratory face mask has been developed for use with unsedated beagles trained to run on a treadmill. The latex rubber mask, shaped to fit the animal's muzzle, incorporates two modified, commercially available, pulmonary valves for separating inspiratory and expiratory flows. The mask has a dead space of 30 cm3 and a flow resistance below 1 cmH2O . 1(-1) . s. The flexible mask is used to measure breath-by-breath respiratory variables over extended periods of time during rest and exercise.

  5. Communication masking in marine mammals: A review and research strategy.

    Science.gov (United States)

    Erbe, Christine; Reichmuth, Colleen; Cunningham, Kane; Lucke, Klaus; Dooling, Robert

    2016-02-15

    Underwater noise, whether of natural or anthropogenic origin, has the ability to interfere with the way in which marine mammals receive acoustic signals (i.e., for communication, social interaction, foraging, navigation, etc.). This phenomenon, termed auditory masking, has been well studied in humans and terrestrial vertebrates (in particular birds), but less so in marine mammals. Anthropogenic underwater noise seems to be increasing in parts of the world's oceans and concerns about associated bioacoustic effects, including masking, are growing. In this article, we review our understanding of masking in marine mammals, summarise data on marine mammal hearing as they relate to masking (including audiograms, critical ratios, critical bandwidths, and auditory integration times), discuss masking release processes of receivers (including comodulation masking release and spatial release from masking) and anti-masking strategies of signalers (e.g. Lombard effect), and set a research framework for improved assessment of potential masking in marine mammals. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Masking interrupts figure-ground signals in V1.

    Science.gov (United States)

    Lamme, Victor A F; Zipser, Karl; Spekreijse, Henk

    2002-10-01

    In a backward masking paradigm, a target stimulus is rapidly (figure-ground segregation can be recorded. Here, we recorded from awake macaque monkeys, engaged in a task where they had to detect figures from background in a pattern backward masking paradigm. We show that the V1 figure-ground signals are selectively and fully suppressed at target-mask intervals that psychophysically result in the target being invisible. Initial response transients, signalling the features that make up the scene, are not affected. As figure-ground modulations depend on feedback from extrastriate areas, these results suggest that masking selectively interrupts the recurrent interactions between V1 and higher visual areas.

  7. Estimation of the Ideal Binary Mask using Directional Systems

    DEFF Research Database (Denmark)

    Boldt, Jesper; Kjems, Ulrik; Pedersen, Michael Syskind

    2008-01-01

    The ideal binary mask is often seen as a goal for time-frequency masking algorithms trying to increase speech intelligibility, but the required availability of the unmixed signals makes it difficult to calculate the ideal binary mask in any real-life applications. In this paper we derive the theory...... and the requirements to enable calculations of the ideal binary mask using a directional system without the availability of the unmixed signals. The proposed method has a low complexity and is verified using computer simulation in both ideal and non-ideal setups showing promising results....

  8. Improvement of radiographs by means of optical masks

    International Nuclear Information System (INIS)

    Shishov, B.A.; Tereshenko, O.I.; Tyurin, E.I.

    1985-01-01

    High-gradient photographic material improves contrast and detectability of small details. Parts of the radiographs will however tend to be over- or underexposed. The recorded information can be improved by optical masks that modify the light in various parts of the image according to film sensitivity. For screen-film systems an immediate correction of the image by inserted masks results in a better recording of details while the well known detail filtering process improves only the visual detectability of the already recorded information. A special cassette for the generation of masks and a method for the calculation of correction factors for various screen combinations and masks types are described. (author)

  9. Simulation-based MDP verification for leading-edge masks

    Science.gov (United States)

    Su, Bo; Syrel, Oleg; Pomerantsev, Michael; Hagiwara, Kazuyuki; Pearman, Ryan; Pang, Leo; Fujimara, Aki

    2017-07-01

    For IC design starts below the 20nm technology node, the assist features on photomasks shrink well below 60nm and the printed patterns of those features on masks written by VSB eBeam writers start to show a large deviation from the mask designs. Traditional geometry-based fracturing starts to show large errors for those small features. As a result, other mask data preparation (MDP) methods have become available and adopted, such as rule-based Mask Process Correction (MPC), model-based MPC and eventually model-based MDP. The new MDP methods may place shot edges slightly differently from target to compensate for mask process effects, so that the final patterns on a mask are much closer to the design (which can be viewed as the ideal mask), especially for those assist features. Such an alteration generally produces better masks that are closer to the intended mask design. Traditional XOR-based MDP verification cannot detect problems caused by eBeam effects. Much like model-based OPC verification which became a necessity for OPC a decade ago, we see the same trend in MDP today. Simulation-based MDP verification solution requires a GPU-accelerated computational geometry engine with simulation capabilities. To have a meaningful simulation-based mask check, a good mask process model is needed. The TrueModel® system is a field tested physical mask model developed by D2S. The GPU-accelerated D2S Computational Design Platform (CDP) is used to run simulation-based mask check, as well as model-based MDP. In addition to simulation-based checks such as mask EPE or dose margin, geometry-based rules are also available to detect quality issues such as slivers or CD splits. Dose margin related hotspots can also be detected by setting a correct detection threshold. In this paper, we will demonstrate GPU-acceleration for geometry processing, and give examples of mask check results and performance data. GPU-acceleration is necessary to make simulation-based mask MDP verification

  10. Overlay improvement by exposure map based mask registration optimization

    Science.gov (United States)

    Shi, Irene; Guo, Eric; Chen, Ming; Lu, Max; Li, Gordon; Li, Rivan; Tian, Eric

    2015-03-01

    Along with the increased miniaturization of semiconductor electronic devices, the design rules of advanced semiconductor devices shrink dramatically. [1] One of the main challenges of lithography step is the layer-to-layer overlay control. Furthermore, DPT (Double Patterning Technology) has been adapted for the advanced technology node like 28nm and 14nm, corresponding overlay budget becomes even tighter. [2][3] After the in-die mask registration (pattern placement) measurement is introduced, with the model analysis of a KLA SOV (sources of variation) tool, it's observed that registration difference between masks is a significant error source of wafer layer-to-layer overlay at 28nm process. [4][5] Mask registration optimization would highly improve wafer overlay performance accordingly. It was reported that a laser based registration control (RegC) process could be applied after the pattern generation or after pellicle mounting and allowed fine tuning of the mask registration. [6] In this paper we propose a novel method of mask registration correction, which can be applied before mask writing based on mask exposure map, considering the factors of mask chip layout, writing sequence, and pattern density distribution. Our experiment data show if pattern density on the mask keeps at a low level, in-die mask registration residue error in 3sigma could be always under 5nm whatever blank type and related writer POSCOR (position correction) file was applied; it proves random error induced by material or equipment would occupy relatively fixed error budget as an error source of mask registration. On the real production, comparing the mask registration difference through critical production layers, it could be revealed that registration residue error of line space layers with higher pattern density is always much larger than the one of contact hole layers with lower pattern density. Additionally, the mask registration difference between layers with similar pattern density

  11. Laser Doppler imaging of cutaneous blood flow through transparent face masks: a necessary preamble to computer-controlled rapid prototyping fabrication with submillimeter precision.

    Science.gov (United States)

    Allely, Rebekah R; Van-Buendia, Lan B; Jeng, James C; White, Patricia; Wu, Jingshu; Niszczak, Jonathan; Jordan, Marion H

    2008-01-01

    A paradigm shift in management of postburn facial scarring is lurking "just beneath the waves" with the widespread availability of two recent technologies: precise three-dimensional scanning/digitizing of complex surfaces and computer-controlled rapid prototyping three-dimensional "printers". Laser Doppler imaging may be the sensible method to track the scar hyperemia that should form the basis of assessing progress and directing incremental changes in the digitized topographical face mask "prescription". The purpose of this study was to establish feasibility of detecting perfusion through transparent face masks using the Laser Doppler Imaging scanner. Laser Doppler images of perfusion were obtained at multiple facial regions on five uninjured staff members. Images were obtained without a mask, followed by images with a loose fitting mask with and without a silicone liner, and then with a tight fitting mask with and without a silicone liner. Right and left oblique images, in addition to the frontal images, were used to overcome unobtainable measurements at the extremes of face mask curvature. General linear model, mixed model, and t tests were used for data analysis. Three hundred seventy-five measurements were used for analysis, with a mean perfusion unit of 299 and pixel validity of 97%. The effect of face mask pressure with and without the silicone liner was readily quantified with significant changes in mean cutaneous blood flow (P face masks. Perfusion decreases with the application of pressure and with silicone. Every participant measured differently in perfusion units; however, consistent perfusion patterns in the face were observed.

  12. Radioimmunoassays of hidden viral antigens

    International Nuclear Information System (INIS)

    Neurath, A.R.; Strick, N.; Baker, L.; Krugman, S.

    1982-01-01

    Antigens corresponding to infectious agents may be present in biological specimens only in a cryptic form bound to antibodies and, thus, may elude detection. We describe a solid-phase technique for separation of antigens from antibodies. Immune complexes are precipitated from serum by polyethylene glycol, dissociated with NaSCN, and adsorbed onto nitrocellulose or polystyrene supports. Antigens remain topographically separated from antibodies after removal of NaSCN and can be detected with radiolabeled antibodies. Genomes from viruses immobilized on nitrocellulose can be identified by nucleic acid hybridization. Nanogram quantities of sequestered hepatitis B surface and core antigens and picogram amounts of hepatitis B virus DNA were detected. Antibody-bound adenovirus, herpesvirus, and measles virus antigens were discerned by the procedure

  13. Actinic inspection of multilayer defects on EUV masks

    International Nuclear Information System (INIS)

    Barty, A; Liu, Y; Gullikson, E; Taylor, J S; Wood, O

    2005-01-01

    The production of defect-free mask blanks, and the development of techniques for inspecting and qualifying EUV mask blanks, remains a key challenge for EUV lithography. In order to ensure a reliable supply of defect-free mask blanks, it is necessary to develop techniques to reliably and accurately detect defects on un-patterned mask blanks. These inspection tools must be able to accurately detect all critical defects whilst simultaneously having the minimum possible false-positive detection rate. There continues to be improvement in high-speed non-actinic mask blank inspection tools, and it is anticipated that these tools can and will be used by industry to qualify EUV mask blanks. However, the outstanding question remains one of validating that non-actinic inspection techniques are capable of detecting all printable EUV defects. To qualify the performance of non-actinic inspection tools, a unique dual-mode EUV mask inspection system has been installed at the Advanced Light Source (ALS) synchrotron at Lawrence Berkeley National Laboratory. In high-speed inspection mode, whole mask blanks are scanned for defects using 13.5-nm wavelength light to identify and map all locations on the mask that scatter a significant amount of EUV light. In imaging, or defect review mode, a zone plate is placed in the reflected beam path to image a region of interest onto a CCD detector with an effective resolution on the mask of 100-nm or better. Combining the capabilities of the two inspection tools into one system provides the unique capability to determine the coordinates of native defects that can be used to compare actinic defect inspection with visible light defect inspection tools under commercial development, and to provide data for comparing scattering models for EUV mask defects

  14. COLONOSCOPY AND CARCINOEMBRYONIC ANTIGEN VARIATIONS

    Directory of Open Access Journals (Sweden)

    Rita G SOUSA

    2014-03-01

    Full Text Available Context Colonoscopy is essential for synchronous and metachronous cancer detection. Carcinoembryonic antigen is a colorectal cancer tumor marker, important as a follow-up tool in patients with previous colorectal cancer. False-positive carcinoembryonic antigen elevation results in multiples exams and in patient anxiety. In literature, there is reference to transient carcinoembryonic antigen increase with colonoscopy. Objective To evaluate the influence of bowel preparation and colonoscopy in carcinoembryonic antigen blood levels. Methods We prospectively studied subjects that underwent routine colonoscopy in our institution. Blood samples were collected (1 before bowel cleaning, (2 before colonoscopy and (3 immediately after colonoscopy. Blood carcinoembryonic antigen levels were determined by “Sandwich” immunoassay. The statistical methods used were the paired t-test and ANOVA. Results Thirty-seven patients (22M/15F were included; age range 28-84 (mean 56 years. Mean carcinoembryonic antigen values were 1.9, 2 and 1.8 for (1, (2 and (3, respectively. An increase in value (2 compared with (1 was observed in 20/37 patients (P = 0.018, mainly in younger patients and in patients requiring more endoluminal interventions. In 29/37 patients, the CEA value decreased from (2 to (3 (P = 1.3x10-7. Conclusions A trend for carcinoembryonic antigen increase after bowel cleaning was observed, especially in younger patients and in patients with more endoluminal interventions, but without clinical meaning.

  15. Coherent diffractive imaging using randomly coded masks

    Energy Technology Data Exchange (ETDEWEB)

    Seaberg, Matthew H., E-mail: seaberg@slac.stanford.edu [CNRS and D.I., UMR 8548, École Normale Supérieure, 45 Rue d' Ulm, 75005 Paris (France); Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); D' Aspremont, Alexandre [CNRS and D.I., UMR 8548, École Normale Supérieure, 45 Rue d' Ulm, 75005 Paris (France); Turner, Joshua J. [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States)

    2015-12-07

    We experimentally demonstrate an extension to coherent diffractive imaging that encodes additional information through the use of a series of randomly coded masks, removing the need for typical object-domain constraints while guaranteeing a unique solution to the phase retrieval problem. Phase retrieval is performed using a numerical convex relaxation routine known as “PhaseCut,” an iterative algorithm known for its stability and for its ability to find the global solution, which can be found efficiently and which is robust to noise. The experiment is performed using a laser diode at 532.2 nm, enabling rapid prototyping for future X-ray synchrotron and even free electron laser experiments.

  16. Masking properties of ceramics for veneer restorations.

    Science.gov (United States)

    Skyllouriotis, Andreas L; Yamamoto, Hideo L; Nathanson, Dan

    2017-10-01

    The translucency and opacity of ceramics play a significant role in emulating the natural color of teeth, but studies of the masking properties and limitations of dental ceramics when used as monolayer restorations are lacking. The purpose of this in vitro study was to determine the translucency of 6 materials used for veneer restorations by assessing their translucency parameters (TPs), contrast ratios (CRs), and potential to mask dark tooth colors. Ten square- or disk-shaped specimens (0.5-mm thickness, shade A2) were fabricated from Vitablocks Mark II (VMII; Vita Zahnfabrik), IPS e.max CAD LT (EMXC LT; Ivoclar Vivadent AG), IPS e.max CAD HT (EMXC HT; Ivoclar Vivadent AG), IPS Empress CAD LT (EMP LT; Ivoclar Vivadent AG), IPS e.max Press LT (EMXP LT; Ivoclar Vivadent AG), and CZR (CZR; Kuraray Noritake Dental Inc). Their luminance (Y) values over black and over white tiles were measured, followed by their color (CIELab) over black tiles and white tiles and shaded A2 (control group), A3.5, A4, and B4 acrylic resin blocks. All measurements were performed using a spectrophotometer in 2 different areas on each specimen. Then CRs, TPs, and color differences (over shaded backgrounds) were determined. Data were subjected to 1-way and 2-way ANOVA (α=.05) for analysis. Mean CR values of EMXP LT were significantly higher than those of the other tested materials, whereas VMII and EMXC HT had the lowest values (Pmasking properties against the A4 background. The color differences of most tested ceramics were more acceptable when tested against the B4 background (ΔE*≤3.3). Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Prevalence and persistence of masked hypertension in treated hypertensive patients

    NARCIS (Netherlands)

    Verberk, Willem J.; Thien, Theo; Kroon, Abraham A.; Lenders, Jacques W. M.; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    2007-01-01

    Background: Masked hypertension (MH) is defined as a normal blood pressure in the physician's office and an elevated blood pressure when measured out-of-office. The cause of MH may be termed the masked hypertension effect (MHE), and is not restricted to blood-pressure (BP) values around the

  18. Prevalence and persistence of masked hypertension in treated hypertensive patients.

    NARCIS (Netherlands)

    Verberk, W.J.; Thien, Th.; Kroon, A.A.; Lenders, J.W.M.; Montfrans, G.A. van; Smit, A.J.; Leeuw, P.W. de

    2007-01-01

    BACKGROUND: Masked hypertension (MH) is defined as a normal blood pressure in the physician's office and an elevated blood pressure when measured out-of-office. The cause of MH may be termed the masked hypertension effect (MHE), and is not restricted to blood-pressure (BP) values around the

  19. Prevalence and persistence of masked hypertension in treated hypertensive patients

    NARCIS (Netherlands)

    Verberk, Willem J.; Thien, Theo; Kroon, Abraham A.; Lenders, Jacques W. M.; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    2007-01-01

    BACKGROUND: Masked hypertension (MH) is defined as a normal blood pressure in the physician's office and an elevated blood pressure when measured out-of-office. The cause of MH may be termed the masked hypertension effect (MHE), and is not restricted to blood-pressure (BP) values around the

  20. Self-masking: Listening during vocalization. Normal hearing.

    Science.gov (United States)

    Borg, Erik; Bergkvist, Christina; Gustafsson, Dan

    2009-06-01

    What underlying mechanisms are involved in the ability to talk and listen simultaneously and what role does self-masking play under conditions of hearing impairment? The purpose of the present series of studies is to describe a technique for assessment of masked thresholds during vocalization, to describe normative data for males and females, and to focus on hearing impairment. The masking effect of vocalized [a:] on narrow-band noise pulses (250-8000 Hz) was studied using the maximum vocalization method. An amplitude-modulated series of sound pulses, which sounded like a steam engine, was masked until the criterion of halving the perceived pulse rate was reached. For masking of continuous reading, a just-follow-conversation criterion was applied. Intra-session test-retest reproducibility and inter-session variability were calculated. The results showed that female voices were more efficient in masking high frequency noise bursts than male voices and more efficient in masking both a male and a female test reading. The male had to vocalize 4 dBA louder than the female to produce the same masking effect on the test reading. It is concluded that the method is relatively simple to apply and has small intra-session and fair inter-session variability. Interesting gender differences were observed.

  1. Failed tracheal intubation using a laryngoscope and intubating laryngeal mask.

    Science.gov (United States)

    Asai, T; Hirose, T; Shingu, K

    2000-04-01

    To report unexpected failed tracheal intubation using a laryngoscope and an intubating laryngeal mask, and difficult ventilation via a facemask, laryngeal mask and intubating laryngeal mask, in a patient with an unrecognized lingual tonsillar hypertrophy. A 63-yr-old woman, who had undergone clipping of an aneurysm seven weeks previously, was scheduled for ventriculo-peritoneal shunt. At the previous surgery, there had been no difficulty in ventilation or in tracheal intubation. Her trachea remained intubated nasally for 11 days after surgery. Preoperatively, her consciousness was impaired. There were no restrictions in head and neck movements or mouth opening. The thyromental distance was 7 cm. After induction of anesthesia, manual ventilation via a facemask with a Guedel airway was suboptimal and the chest expanded insufficiently. At laryngoscopy using a Macintosh or McCoy device, only the tip of the epiglottis, but not the glottis, could be seen, and tracheal intubation failed. There was a partial obstruction during manual ventilation through either the intubating laryngeal mask or conventional laryngeal mask; intubation through each device failed. Digital examination of the pharynx, after removal of the laryngeal mask, indicated a mass occupying the vallecula. Lingual tonsillar hypertrophy (1 x 1 x 2 cm) was found to be the cause of the failure. Awake fibrescope-aided tracheal intubation was accomplished. Unexpected lingual tonsillar hypertrophy can cause both ventilation and tracheal intubation difficult, and neither the laryngeal mask nor intubating laryngeal mask may be helpful in the circumstances.

  2. Dead space variability of face masks for valved holding chambers.

    Science.gov (United States)

    Amirav, Israel; Newhouse, Michael T

    2008-03-01

    Valved holding chambers with masks are commonly used to deliver inhaled medications to young children with asthma. Optimal mask properties such as their dead space volume have received little attention. The smaller the mask the more likely it is that a greater proportion of the dose in the VHC will be inhaled with each breath, thus speeding VHC emptying and improving overall aerosol delivery efficiency and dose. Masks may have different DSV and thus different performance. To compare both physical dead space and functional dead space of different face masks under various applied pressures. The DSV of three commonly used face masks of VHCs was measured by water displacement both under various pressures (to simulate real-life application, dynamic DSV) and under no pressure (static DSV). There was a great variability of both static and dynamic dead space among various face mask for VHCs, which is probably related to their flexibility. Different masks have different DSV characteristics. This variability should be taken into account when comparing the clinical efficacy of various VHCs.

  3. Ni-Al Alloys as Alternative EUV Mask Absorber

    Directory of Open Access Journals (Sweden)

    Vu Luong

    2018-03-01

    Full Text Available Extreme ultraviolet (EUV lithography is being industrialized as the next candidate printing technique for high-volume manufacturing of scaled down integrated circuits. At mask level, the combination of EUV light at oblique incidence, absorber thickness, and non-uniform mirror reflectance through incidence angle, creates photomask-induced imaging aberrations, known as mask 3D (M3D effects. A possible mitigation for the M3D effects in the EUV binary intensity mask (BIM, is to use mask absorber materials with high extinction coefficient κ and refractive coefficient n close to unity. We propose nickel aluminide alloys as a candidate BIM absorber material, and characterize them versus a set of specifications that a novel EUV mask absorber must meet. The nickel aluminide samples have reduced crystallinity as compared to metallic nickel, and form a passivating surface oxide layer in neutral solutions. Composition and density profile are investigated to estimate the optical constants, which are then validated with EUV reflectometry. An oxidation-induced Al L2 absorption edge shift is observed, which significantly impacts the value of n at 13.5 nm wavelength and moves it closer to unity. The measured optical constants are incorporated in an accurate mask model for rigorous simulations. The M3D imaging impact of the nickel aluminide alloy mask absorbers, which predict significant M3D reduction in comparison to reference absorber materials. In this paper, we present an extensive experimental methodology flow to evaluate candidate mask absorber materials.

  4. Energy enhancer for mask based laser materials processing

    DEFF Research Database (Denmark)

    Bastue, Jens; Olsen, Flemmming Ove

    1996-01-01

    A device capable of drastically improving the energy efficiency of present mask based laser materials processing systems is presented. Good accordance between experiments and simulations for a TEA-CO2 laser system designed for laser marking has been demonstrated. The energy efficiency may...... be improved with a factor of 2 - 4 for typical mask transmittances between 10 - 40%....

  5. My Other Half Manifested in Mask-Making

    Science.gov (United States)

    Abel, Xanthippi

    2010-01-01

    Every fall season, each grade level of Rowland Hall St. Mark's Lower School in Salt Lake City, Utah, completes a mask-making project to be featured in a schoolwide parade. This sparked an opportunity to incorporate the fourth-grade unit of realistic and observational drawing with mask making. In this article, the author describes how her students…

  6. GABAA agonist reduces visual awareness : a masking-EEG experiment

    NARCIS (Netherlands)

    van Loon, Anouk M; Scholte, H Steven; van Gaal, Simon; van der Hoort, Björn J J; Lamme, Victor A F

    Consciousness can be manipulated in many ways. Here, we seek to understand whether two such ways, visual masking and pharmacological intervention, share a common pathway in manipulating visual consciousness. We recorded EEG from human participants who performed a backward-masking task in which they

  7. Reusable High Aspect Ratio 3-D Nickel Shadow Mask

    Science.gov (United States)

    Shandhi, M.M.H.; Leber, M.; Hogan, A.; Warren, D.J.; Bhandari, R.; Negi, S.

    2017-01-01

    Shadow Mask technology has been used over the years for resistless patterning and to pattern on unconventional surfaces, fragile substrate and biomaterial. In this work, we are presenting a novel method to fabricate high aspect ratio (15:1) three-dimensional (3D) Nickel (Ni) shadow mask with vertical pattern length and width of 1.2 mm and 40 μm respectively. The Ni shadow mask is 1.5 mm tall and 100 μm wide at the base. The aspect ratio of the shadow mask is 15. Ni shadow mask is mechanically robust and hence easy to handle. It is also reusable and used to pattern the sidewalls of unconventional and complex 3D geometries such as microneedles or neural electrodes (such as the Utah array). The standard Utah array has 100 active sites at the tip of the shaft. Using the proposed high aspect ratio Ni shadow mask, the Utah array can accommodate 300 active sites, 200 of which will be along and around the shaft. The robust Ni shadow mask is fabricated using laser patterning and electroplating techniques. The use of Ni 3D shadow mask will lower the fabrication cost, complexity and time for patterning out-of-plane structures. PMID:29056835

  8. Mask Materials and Designs for Extreme Ultra Violet Lithography

    Science.gov (United States)

    Kim, Jung Sik; Ahn, Jinho

    2018-03-01

    Extreme ultra violet lithography (EUVL) is no longer a future technology but is going to be inserted into mass production of semiconductor devices of 7 nm technology node in 2018. EUVL is an extension of optical lithography using extremely short wavelength (13.5 nm). This short wavelength requires major modifications in the optical systems due to the very strong absorption of EUV light by materials. Refractive optics can no longer be used, and reflective optics is the only solution to transfer image from mask to wafer. This is why we need the multilayer (ML) mirror-based mask as well as an oblique incident angle of light. This paper discusses the principal theory on the EUV mask design and its component materials including ML reflector and EUV absorber. Mask shadowing effect (or mask 3D effect) is explained and its technical solutions like phase shift mask is reviewed. Even though not all the technical issues on EUV mask are handled in this review paper, you will be able to understand the principles determining the performance of EUV masks.

  9. Masked hypertension: evidence of the need to treat

    NARCIS (Netherlands)

    Ogedegbe, Gbenga; Agyemang, Charles; Ravenell, Joseph E.

    2010-01-01

    The diagnosis of masked hypertension has been made easier with the widespread availability of home blood pressure monitoring devices with levels of accuracy comparable to ambulatory blood pressure monitoring. The negative impact of masked hypertension on cardiovascular morbidity and mortality is

  10. Migration from full-head mask to "open-face" mask for immobilization of patients with head and neck cancer.

    Science.gov (United States)

    Li, Guang; Lovelock, D Michael; Mechalakos, James; Rao, Shyam; Della-Biancia, Cesar; Amols, Howard; Lee, Nancy

    2013-09-06

    To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an "open-face" thermoplastic mask was evaluated using video-based optical surface imaging (OSI) and kilovoltage (kV) X-ray radiography. A three-point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real-time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open-face and full-head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open-face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real-time OSI. With the open-face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre-/post-treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask-locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open-face and full-head masks were found to be similar. Most (80%) of the volunteers preferred the open-face mask to the full-head mask, while claustrophobic patients could only tolerate the open-face mask. The open-face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open-face mask is readily adopted in radiotherapy clinic as a superior alternative to

  11. The difficult business model for mask equipment makers and mask infrastructure development support from consortia and governments

    Science.gov (United States)

    Hector, Scott

    2005-11-01

    The extension of optical projection lithography through immersion to patterning features with half pitch face the challenge of being profitable in the small market for mask equipment while encountering significant R&D expenses to bring new generations of mask fabrication equipment to market. The total available market for patterned masks is estimated to be $2.5B to $2.9B per year. The patterned mask market is about 20% of the market size for lithography equipment and materials. The total available market for mask-making equipment is estimated to be about $800M per year. The largest R&D affordability issue arises for the makers of equipment for fabricating masks where total available sales are typically less than ten units per year. SEMATECH has used discounted cash flow models to predict the affordable R&D while maintaining industry accepted internal rates of return. The results have been compared to estimates of the total R&D cost to bring a new generation of mask equipment to market for various types of tools. The analysis revealed that affordability of the required R&D is a significant problem for many suppliers of mask-making equipment. Consortia such as SEMATECH and Selete have played an important role in cost sharing selected mask equipment and material development projects. Governments in the United States, in Europe and in Japan have also helped equipment suppliers with support for R&D. This paper summarizes the challenging business model for mask equipment suppliers and highlight government support for mask equipment and materials development.

  12. Identification of Schistosoma mansoni candidate antigens for diagnosis of schistosomiasis

    Directory of Open Access Journals (Sweden)

    Gardenia Braz Figueiredo Carvalho

    2011-11-01

    Full Text Available The development of a more sensitive diagnostic test for schistosomiasis is needed to overcome the limitations of the use of stool examination in low endemic areas. Using parasite antigens in enzyme linked immunosorbent assay is a promising strategy, however a more rational selection of parasite antigens is necessary. In this study we performed in silico analysis of the Schistosoma mansoni genome, using SchistoDB database and bioinformatic tools for screening immunogenic antigens. Based on evidence of expression in all parasite life stage within the definitive host, extracellular or plasmatic membrane localization, low similarity to human and other helminthic proteins and presence of predicted B cell epitopes, six candidates were selected: a glycosylphosphatidylinositol-anchored 200 kDa protein, two putative cytochrome oxidase subunits, two expressed proteins and one hypothetical protein. The recognition in unidimensional and bidimensional Western blot of protein with similar molecular weight and isoelectric point to the selected antigens by sera from S. mansoni infected mice indicate a good correlation between these two approaches in selecting immunogenic proteins.

  13. IFN-γ fails to overcome inhibition of selected macrophage activation events in response to pathogenic mycobacteria.

    Directory of Open Access Journals (Sweden)

    Shyamala Thirunavukkarasu

    Full Text Available According to most models of mycobacterial infection, inhibition of the pro-inflammatory macrophage immune responses contributes to the persistence of bacteria. Mycobacterium avium subsp. paratuberculosis (MAP is a highly successful pathogen in cattle and sheep and is also implicated as the causative agent of Crohn's disease in humans. Pathogenic mycobacteria such as MAP have developed multiple strategies to evade host defence mechanisms including interfering with the macrophages' capacity to respond to IFN-γ, a feature which might be lacking in non-pathogenic mycobacteria such as M. smegmatis. We hypothesized that pre-sensitisation of macrophages with the pro-inflammatory cytokine IFN-γ would help in overcoming the inhibitory effect of MAP or its antigens on macrophage inflammatory responses. Herein we have compared a series of macrophage activation parameters in response to MAP and M. smegmatis as well as mycobacterial antigens. While IFN-γ did overcome the inhibition in immune suppressive mechanisms in response to MAP antigen as well as M. smegmatis, we could not find a clear role for IFN-γ in overcoming the inhibition of macrophage inflammatory responses to the pathogenic mycobacterium, MAP. We demonstrate that suppression of macrophage defence mechanisms by pathogenic mycobacteria is unlikely to be overcome by prior sensitization with IFN-γ alone. This indicates that IFN-γ signaling pathway-independent mechanisms may exist for overcoming inhibition of macrophage effector functions in response to pathogenic mycobacteria. These findings have important implications in understanding the survival mechanisms of pathogenic mycobacteria directed towards finding better therapeutics and vaccination strategies.

  14. New Y2K problem for mask making (or, Surviving mask data problems after 2000)

    Science.gov (United States)

    Sturgeon, Roger

    1999-08-01

    The Y2K problem has analogies in the mask-making world. With the Y2K problem where a date field has just two bytes for the year, there are some cases of mask-making data in which the file size cannot exceed 2 gigabytes. Where a two-digit date field can only unambiguously use a limited range of values (00 to 99), design coordinates can only cover a range of about 4 billion values, which is getting a little uncomfortable for all of the new applications. In retrospect, with a degree of foresight and planning the Y2K date problem could have been easily solved if new encodings had been allowed in the two- digit field. Likewise, in the mask-making industry we currently have the opportunity to achieve far superior data compression if we allow some new forms of data encoding in our data. But this will require universal agreement. The correct way to look at the Y2K problem is that some information was left out of the data stream due to common understandings that made the additional information superfluous. But as the year 2000 approaches, it has become widely recognized that missing data needs to be stated explicitly, and any ambiguities in the representation of the data will need to be eliminated with precise specifications. In a similar way, old mask data generation methods have had numerous flaws that we have been able to ignore for a long time. But now is the time to fix theses flaws and provide extended capabilities. What is not yet clear is if the old data generation methods can be modified to meet these developing needs. Unilateral action is not likely to lead to much progress, so some united effort is required by all interested parties if success is to be achieved in the brief time that remains.

  15. X-ray face mask and chest shield device

    International Nuclear Information System (INIS)

    Moti, S.

    1981-01-01

    A protective face mask is designed to shield an x-ray technician or machine operator primarily from random secondary or scatter x-rays deflected towards his face, head and neck by the table, walls, equipment and other reflecting elements in an x-ray room or chamber. The face mask and chest shield device can be mounted on a patient's shoulders in reverse attitude to protect the back of a patient's head and neck from the x-ray beam. The face mask is relatively or substantially transparent and contains lead in combination with a plastic ionomer or comonomer, which to a degree absorbs or resists penetration of the random deflected secondary or scatter x-rays or the x-ray beam through the mask. The face mask is removably attachable to the chest shield for easy application of the device to and support upon the shoulders of the technician or the patient. (author)

  16. Comodulation masking release in bit-rate reduction systems

    DEFF Research Database (Denmark)

    Vestergaard, Martin David; Rasmussen, Karsten Bo; Poulsen, Torben

    1999-01-01

    It has been suggested that the level dependence of the upper masking slope be utilized in perceptual models in bit-rate reduction systems. However, comodulation masking release (CMR) phenomena lead to a reduction of the masking effect when a masker and a probe signal are amplitude modulated...... with the same frequency. In bit-rate reduction systems the masker would be the audio signal and the probe signal would represent the quantization noise. Masking curves have been determined for sinusoids and 1-Bark-wide noise maskers in order to investigate the risk of CMR, when quantizing depths are fixed...... in accordance with psycho-acoustical principles. Masker frequencies of 500 Hz, 1 kHz, and 2 kHz have been investigated, and the masking of pure tone probes has been determined in the first four 1/3 octaves above the masker. Modulation frequencies between 6 and 20 Hz were used with a modulation depth of 0...

  17. MODELING SPECTRAL AND TEMPORAL MASKING IN THE HUMAN AUDITORY SYSTEM

    DEFF Research Database (Denmark)

    Dau, Torsten; Jepsen, Morten Løve; Ewert, Stephan D.

    2007-01-01

    An auditory signal processing model is presented that simulates psychoacoustical data from a large variety of experimental conditions related to spectral and temporal masking. The model is based on the modulation filterbank model by Dau et al. [J. Acoust. Soc. Am. 102, 2892-2905 (1997)] but inclu......An auditory signal processing model is presented that simulates psychoacoustical data from a large variety of experimental conditions related to spectral and temporal masking. The model is based on the modulation filterbank model by Dau et al. [J. Acoust. Soc. Am. 102, 2892-2905 (1997...... was tested in conditions of tone-in-noise masking, intensity discrimination, spectral masking with tones and narrowband noises, forward masking with (on- and off-frequency) noise- and pure-tone maskers, and amplitude modulation detection using different noise carrier bandwidths. One of the key properties...

  18. Overcoming challenges to secure a renewable future

    Energy Technology Data Exchange (ETDEWEB)

    McGrath, Rob; Philpott, Angie; Bown, Charles W.; Thompson, Robert; Dunderdale, Kathy

    2010-09-15

    Newfoundland and Labrador is on the brink of two extraordinary energy achievements: 1) becoming one of the world's only jurisdictions thermal generation almost entirely; and 2) making a huge contribution of renewable energy to North America. These achievements require the development of the 3,000 MW Lower Churchill Hydroelectric Project; however, the Project will not be developed without a business case to support it. This paper will highlight how the province, through its Energy Plan, has set the path forward for the future development of its renewable resources, including how it plans to overcome some of the challenges ahead.

  19. Overcoming barriers to membrane protein structure determination.

    Science.gov (United States)

    Bill, Roslyn M; Henderson, Peter J F; Iwata, So; Kunji, Edmund R S; Michel, Hartmut; Neutze, Richard; Newstead, Simon; Poolman, Bert; Tate, Christopher G; Vogel, Horst

    2011-04-01

    After decades of slow progress, the pace of research on membrane protein structures is beginning to quicken thanks to various improvements in technology, including protein engineering and microfocus X-ray diffraction. Here we review these developments and, where possible, highlight generic new approaches to solving membrane protein structures based on recent technological advances. Rational approaches to overcoming the bottlenecks in the field are urgently required as membrane proteins, which typically comprise ~30% of the proteomes of organisms, are dramatically under-represented in the structural database of the Protein Data Bank.

  20. Overcoming the isolation of disadvantaged housing areas

    DEFF Research Database (Denmark)

    Stender, Marie; Bech-Danielsen, Claus

    Disadvantaged social housing areas in Denmark are currently subject to more thorough physical refurbishments, aiming to overcome the isolated character of the housing estates. The ambition is to attract new users and residents by opening up the borders of the area and establish attractive, new...... penthouse flats, new urban functions within the area or spectacular new public spaces near it. In this paper the social impact of such transformations are analysed and discussed based on case-studies in 3 Danish areas. The analysis shows that especially everyday-route strategies adding new public functions...

  1. Overcome IMF crisis with idea and invention

    International Nuclear Information System (INIS)

    Wang, Yeon Jung

    1998-01-01

    This book introduces the invention as a tool to overcome IMF crisis. These are the titles of the way to create invention and idea : what is idea? everyone can create something, have a confidence, this is patent, replace or change something, invention is not logical, challenge the normal law, throw away stereotype, movement of idea, original imagination, there are a lot of solutions, there is no expert, have a positive thought, why does inventor invent? necessity is invention of mother, three stage of idea and invention and imitation for invention.

  2. Overcome IMF crisis with idea and invention

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yeon Jung

    1998-01-15

    This book introduces the invention as a tool to overcome IMF crisis. These are the titles of the way to create invention and idea : what is idea? everyone can create something, have a confidence, this is patent, replace or change something, invention is not logical, challenge the normal law, throw away stereotype, movement of idea, original imagination, there are a lot of solutions, there is no expert, have a positive thought, why does inventor invent? necessity is invention of mother, three stage of idea and invention and imitation for invention.

  3. New method of 2-dimensional metrology using mask contouring

    Science.gov (United States)

    Matsuoka, Ryoichi; Yamagata, Yoshikazu; Sugiyama, Akiyuki; Toyoda, Yasutaka

    2008-10-01

    We have developed a new method of accurately profiling and measuring of a mask shape by utilizing a Mask CD-SEM. The method is intended to realize high accuracy, stability and reproducibility of the Mask CD-SEM adopting an edge detection algorithm as the key technology used in CD-SEM for high accuracy CD measurement. In comparison with a conventional image processing method for contour profiling, this edge detection method is possible to create the profiles with much higher accuracy which is comparable with CD-SEM for semiconductor device CD measurement. This method realizes two-dimensional metrology for refined pattern that had been difficult to measure conventionally by utilizing high precision contour profile. In this report, we will introduce the algorithm in general, the experimental results and the application in practice. As shrinkage of design rule for semiconductor device has further advanced, an aggressive OPC (Optical Proximity Correction) is indispensable in RET (Resolution Enhancement Technology). From the view point of DFM (Design for Manufacturability), a dramatic increase of data processing cost for advanced MDP (Mask Data Preparation) for instance and surge of mask making cost have become a big concern to the device manufacturers. This is to say, demands for quality is becoming strenuous because of enormous quantity of data growth with increasing of refined pattern on photo mask manufacture. In the result, massive amount of simulated error occurs on mask inspection that causes lengthening of mask production and inspection period, cost increasing, and long delivery time. In a sense, it is a trade-off between the high accuracy RET and the mask production cost, while it gives a significant impact on the semiconductor market centered around the mask business. To cope with the problem, we propose the best method of a DFM solution using two-dimensional metrology for refined pattern.

  4. Oncogenic cancer/testis antigens

    DEFF Research Database (Denmark)

    Gjerstorff, Morten F; Andersen, Mads H; Ditzel, Henrik J

    2015-01-01

    Recent developments have set the stage for immunotherapy as a supplement to conventional cancer treatment. Consequently, a significant effort is required to further improve efficacy and specificity, particularly the identification of optimal therapeutic targets for clinical testing. Cancer....../testis antigens are immunogenic, highly cancer-specific, and frequently expressed in various types of cancer, which make them promising candidate targets for cancer immunotherapy, including cancer vaccination and adoptive T-cell transfer with chimeric T-cell receptors. Our current understanding of tumor...... immunology and immune escape suggests that targeting oncogenic antigens may be beneficial, meaning that identification of cancer/testis antigens with oncogenic properties is of high priority. Recent work from our lab and others provide evidence that many cancer/testis antigens, in fact, have oncogenic...

  5. Natural selection promotes antigenic evolvability.

    Science.gov (United States)

    Graves, Christopher J; Ros, Vera I D; Stevenson, Brian; Sniegowski, Paul D; Brisson, Dustin

    2013-01-01

    The hypothesis that evolvability - the capacity to evolve by natural selection - is itself the object of natural selection is highly intriguing but remains controversial due in large part to a paucity of direct experimental evidence. The antigenic variation mechanisms of microbial pathogens provide an experimentally tractable system to test whether natural selection has favored mechanisms that increase evolvability. Many antigenic variation systems consist of paralogous unexpressed 'cassettes' that recombine into an expression site to rapidly alter the expressed protein. Importantly, the magnitude of antigenic change is a function of the genetic diversity among the unexpressed cassettes. Thus, evidence that selection favors among-cassette diversity is direct evidence that natural selection promotes antigenic evolvability. We used the Lyme disease bacterium, Borrelia burgdorferi, as a model to test the prediction that natural selection favors amino acid diversity among unexpressed vls cassettes and thereby promotes evolvability in a primary surface antigen, VlsE. The hypothesis that diversity among vls cassettes is favored by natural selection was supported in each B. burgdorferi strain analyzed using both classical (dN/dS ratios) and Bayesian population genetic analyses of genetic sequence data. This hypothesis was also supported by the conservation of highly mutable tandem-repeat structures across B. burgdorferi strains despite a near complete absence of sequence conservation. Diversification among vls cassettes due to natural selection and mutable repeat structures promotes long-term antigenic evolvability of VlsE. These findings provide a direct demonstration that molecular mechanisms that enhance evolvability of surface antigens are an evolutionary adaptation. The molecular evolutionary processes identified here can serve as a model for the evolution of antigenic evolvability in many pathogens which utilize similar strategies to establish chronic infections.

  6. Natural selection promotes antigenic evolvability.

    Directory of Open Access Journals (Sweden)

    Christopher J Graves

    Full Text Available The hypothesis that evolvability - the capacity to evolve by natural selection - is itself the object of natural selection is highly intriguing but remains controversial due in large part to a paucity of direct experimental evidence. The antigenic variation mechanisms of microbial pathogens provide an experimentally tractable system to test whether natural selection has favored mechanisms that increase evolvability. Many antigenic variation systems consist of paralogous unexpressed 'cassettes' that recombine into an expression site to rapidly alter the expressed protein. Importantly, the magnitude of antigenic change is a function of the genetic diversity among the unexpressed cassettes. Thus, evidence that selection favors among-cassette diversity is direct evidence that natural selection promotes antigenic evolvability. We used the Lyme disease bacterium, Borrelia burgdorferi, as a model to test the prediction that natural selection favors amino acid diversity among unexpressed vls cassettes and thereby promotes evolvability in a primary surface antigen, VlsE. The hypothesis that diversity among vls cassettes is favored by natural selection was supported in each B. burgdorferi strain analyzed using both classical (dN/dS ratios and Bayesian population genetic analyses of genetic sequence data. This hypothesis was also supported by the conservation of highly mutable tandem-repeat structures across B. burgdorferi strains despite a near complete absence of sequence conservation. Diversification among vls cassettes due to natural selection and mutable repeat structures promotes long-term antigenic evolvability of VlsE. These findings provide a direct demonstration that molecular mechanisms that enhance evolvability of surface antigens are an evolutionary adaptation. The molecular evolutionary processes identified here can serve as a model for the evolution of antigenic evolvability in many pathogens which utilize similar strategies to establish

  7. Reshaping transport operations to overcome new challenges

    Energy Technology Data Exchange (ETDEWEB)

    Harari, F.; Blachet, L. [COGEMA Logistics, (AREVA Group) (France)

    2004-07-01

    After more than 30 years of Spent Fuel Nuclear Fuel (SFN) and High Level Waste (HLW) casks shipments to and from the COGEMA reprocessing factories in LA HAGUE, COGEMA LOGISTICS has demonstrated a unique outstanding performance in transportation for the benefit of its international customers and has integrated all feed-back from past successful operations. While maintaining the highest safety and security records, the last 5 years have been a major challenge to overcome the increase in transport throughputs, regulatory requirements, specific customer demands and new environmental approach (both COGEMA-La Hague and COGEMA LOGISTICS have been certified ISO14001 since 2003). Improvements in procedures, equipments, controls, inspection and organization have been undertaken. Additional important logistics means such as cranes, lifting devices, spreaders were put in operations in the dedicated workshop of our road and maritime facilities as well as in our rail terminals. Thus COGEMA LOGISTICS has developed and improved important logistics means in the Cherbourg area for the loading and unloading operations of heavy casks (i.e. whose weight is between 25 and 120 tons) among three modes of freight (road, railway or maritime transportation). In Valognes, which is currently the most important railway terminal in the world for the transfer of nuclear materials, about 1200 transfers of heavy casks were performed in 2003. New transport equipment and assets were integrated successfully to answer the new requirements for the best interest of our customers. This paper will provide information about equipments and management system developed to overcome these challenges.

  8. Reshaping transport operations to overcome new challenges

    International Nuclear Information System (INIS)

    Harari, F.; Blachet, L.

    2004-01-01

    After more than 30 years of Spent Fuel Nuclear Fuel (SFN) and High Level Waste (HLW) casks shipments to and from the COGEMA reprocessing factories in LA HAGUE, COGEMA LOGISTICS has demonstrated a unique outstanding performance in transportation for the benefit of its international customers and has integrated all feed-back from past successful operations. While maintaining the highest safety and security records, the last 5 years have been a major challenge to overcome the increase in transport throughputs, regulatory requirements, specific customer demands and new environmental approach (both COGEMA-La Hague and COGEMA LOGISTICS have been certified ISO14001 since 2003). Improvements in procedures, equipments, controls, inspection and organization have been undertaken. Additional important logistics means such as cranes, lifting devices, spreaders were put in operations in the dedicated workshop of our road and maritime facilities as well as in our rail terminals. Thus COGEMA LOGISTICS has developed and improved important logistics means in the Cherbourg area for the loading and unloading operations of heavy casks (i.e. whose weight is between 25 and 120 tons) among three modes of freight (road, railway or maritime transportation). In Valognes, which is currently the most important railway terminal in the world for the transfer of nuclear materials, about 1200 transfers of heavy casks were performed in 2003. New transport equipment and assets were integrated successfully to answer the new requirements for the best interest of our customers. This paper will provide information about equipments and management system developed to overcome these challenges

  9. Disposition of overcoming students for critical reading

    Directory of Open Access Journals (Sweden)

    Rosangela Miola Galvão

    2018-03-01

    Full Text Available This article aims to present the possibilities of an educational practice that focuses on the formation of Basic Education students in critical readers. For this, understand the concepts of alienation and language from the point of view of Historical and Dialectical Materialism and Historical-Cultural Theory was essential to understand how the students of the 7th year are able to overcome this paradigm that contributes to the naive reading of texts worked in the classroom. It was a qualitative study of bibliographic revision in union with the dialectical practice with students in a public school located in the north of the State of Paraná. As methodology, was developed twelve classes with diversified material in which the teacher's mediation sought to contemplate form and content in the way that occurred the deconstruction of the fictitious hero concept represented at the end by the art of the haicai poem. The use of the cell phone instrument and Whatsapp were important for the development of the poetic sense. It seeks, therefore, to demonstrate the contributions of historical and dialectical materialism to teaching practice and human development. The theorists considerations allow us to note that language contributes to the development of higher psychic functions in man and the alienation of subjects in today's society considerably affects the students interpretation and, consequently, formation for critical reading, which can be overcome with the use of a conscious theoretical current.

  10. Enumerating actinomycetes in compost bioaerosols at source—Use of soil compost agar to address plate 'masking'

    Science.gov (United States)

    Taha, M. P. M.; Drew, G. H.; Tamer Vestlund, A.; Aldred, D.; Longhurst, P. J.; Pollard, S. J. T.

    Actinomycetes are the dominant bacteria isolated from bioaerosols sampled at composting facilities. Here, a novel method for the isolation of actinomycetes is reported, overcoming masking of conventional agar plates, as well as reducing analysis time and costs. Repeatable and reliable actinomycetes growth was best achieved using a soil compost media at an incubation temperature of 44 °C and 7 days' incubation. The results are of particular value to waste management operators and their advisors undertaking regulatory risk assessments that support environmental approvals for compost facilities.

  11. Objective measures of binaural masking level differences and comodulation masking release based on late auditory evoked potentials

    DEFF Research Database (Denmark)

    Epp, Bastian; Yasin, Ifat; Verhey, Jesko L.

    2013-01-01

    at a fixed physical intensity is varied by introducing auditory cues of (i) interaural target signal phase disparity and (ii) coherent masker level fluctuations in different frequency regions. In agreement with previous studies, psychoacoustical experiments showed that both stimulus manipulations result......The audibility of important sounds is often hampered due to the presence of other masking sounds. The present study investigates if a correlate of the audibility of a tone masked by noise is found in late auditory evoked potentials measured from human listeners. The audibility of the target sound...... in a masking release (i: binaural masking level difference; ii: comodulation masking release) compared to a condition where those cues are not present. Late auditory evoked potentials (N1, P2) were recorded for the stimuli at a constant masker level, but different signal levels within the same set of listeners...

  12. Simulation based mask defect repair verification and disposition

    Science.gov (United States)

    Guo, Eric; Zhao, Shirley; Zhang, Skin; Qian, Sandy; Cheng, Guojie; Vikram, Abhishek; Li, Ling; Chen, Ye; Hsiang, Chingyun; Zhang, Gary; Su, Bo

    2009-10-01

    As the industry moves towards sub-65nm technology nodes, the mask inspection, with increased sensitivity and shrinking critical defect size, catches more and more nuisance and false defects. Increased defect counts pose great challenges in the post inspection defect classification and disposition: which defect is real defect, and among the real defects, which defect should be repaired and how to verify the post-repair defects. In this paper, we address the challenges in mask defect verification and disposition, in particular, in post repair defect verification by an efficient methodology, using SEM mask defect images, and optical inspection mask defects images (only for verification of phase and transmission related defects). We will demonstrate the flow using programmed mask defects in sub-65nm technology node design. In total 20 types of defects were designed including defects found in typical real circuit environments with 30 different sizes designed for each type. The SEM image was taken for each programmed defect after the test mask was made. Selected defects were repaired and SEM images from the test mask were taken again. Wafers were printed with the test mask before and after repair as defect printability references. A software tool SMDD-Simulation based Mask Defect Disposition-has been used in this study. The software is used to extract edges from the mask SEM images and convert them into polygons to save in GDSII format. Then, the converted polygons from the SEM images were filled with the correct tone to form mask patterns and were merged back into the original GDSII design file. This merge is for the purpose of contour simulation-since normally the SEM images cover only small area (~1 μm) and accurate simulation requires including larger area of optical proximity effect. With lithography process model, the resist contour of area of interest (AOI-the area surrounding a mask defect) can be simulated. If such complicated model is not available, a simple

  13. Overcoming immunological barriers in regenerative medicine.

    Science.gov (United States)

    Zakrzewski, Johannes L; van den Brink, Marcel R M; Hubbell, Jeffrey A

    2014-08-01

    Regenerative therapies that use allogeneic cells are likely to encounter immunological barriers similar to those that occur with transplantation of solid organs and allogeneic hematopoietic stem cells (HSCs). Decades of experience in clinical transplantation hold valuable lessons for regenerative medicine, offering approaches for developing tolerance-induction treatments relevant to cell therapies. Outside the field of solid-organ and allogeneic HSC transplantation, new strategies are emerging for controlling the immune response, such as methods based on biomaterials or mimicry of antigen-specific peripheral tolerance. Novel biomaterials can alter the behavior of cells in tissue-engineered constructs and can blunt host immune responses to cells and biomaterial scaffolds. Approaches to suppress autoreactive immune cells may also be useful in regenerative medicine. The most innovative solutions will be developed through closer collaboration among stem cell biologists, transplantation immunologists and materials scientists.

  14. Desensitization: Overcoming the Immunologic Barriers to Transplantation

    Science.gov (United States)

    Choi, Jua; Vo, Ashley; Peng, Alice; Jordan, Stanley C.

    2017-01-01

    HLA (Human Leucocyte Antigen) sensitization is a significant barrier to successful kidney transplantation. It often translates into difficult crossmatch before transplant and increased risk of acute and chronic antibody mediated rejection after transplant. Over the last decade, several immunomodulatory therapies have emerged allowing for increased access to kidney transplantation for the immunologically disadvantaged group of HLA sensitized end stage kidney disease patients. These include IgG inactivating agents, anti-cytokine antibodies, costimulatory molecule blockers, complement inhibitors, and agents targeting plasma cells. In this review, we discuss currently available agents for desensitization and provide a brief analysis of data on novel biologics, which will likely improve desensitization outcomes, and have potential implications in treatment of antibody mediated rejection. PMID:28127571

  15. Science, Technology and Natural Resources Policy: Overcoming Congressional Gridlock

    Science.gov (United States)

    McCurdy, K. M.

    2015-12-01

    The current status of Science, Technology and Natural Resources (STNR) policy in the United States provides an ideal context to examine the influence of committee seniority within the public policy process. Exemplars of the Policy Entrepreneur have been individuals in leadership positions, whether executive or legislative. The role of junior committee members in shaping policy innovation is less well understood, and is frequently masked either in cross-sectional research designs or in case studies. The House Natural Resources committee seniority patterns are compared to the House of Representatives Chamber data from 1975 to 2015. This expanse of congressional time captures both the policy innovation of the Class of 1974 who helped transform the public lands by pursuing a preservation agenda, along with the contemporaneous gridlock caused by disagreements about reducing the size of the federal government, a policy agenda championed and sustained by the Class of 1994. Several types of political actors have served as policy entrepreneurs, President Kennedy and Secretary of Interior Udall shepherding the Wilderness Act of 1964 from the Executive branch, or in the 111th Congress Committee chairmen Senator Christopher Dodd and Representative Barney Frank, having announced their retirements, spent their final Congress shaping the consensus that produced the Wall Street Reform and Consumer Protection Act of 2010. A less studied policy phenomenon relies on "packing the committee" to outvote the leadership. This tactic can be used by the party leadership to overcome recalcitrant senior committee members, as was the case for Democrats in the House Interior and Insular Affairs Committee shift to preservation in the 1970s, or the tactic can be employed from the grassroots, as may be happening in the case of the House Natural Resources Committee in the 114th Congress. A policy making process analog to rivers is more appropriate than a mechanistic model. As there are multiple

  16. Anvendelse af prostataspecifikt antigen. En oversigt

    DEFF Research Database (Denmark)

    Brasso, K; Skaarup, P; Roosen, Jens Ulrik

    1998-01-01

    Since it was first introduced, measurement of prostate specific antigen has gained increasing interest, and prostate specific antigen is regarded as being the best tumour marker available. The antigen lacks cancer specificity, limiting the usefulness in early diagnosis, The use of prostate specific...... antigen in early diagnosis, staging, and in monitoring patients with prostate cancer is reviewed....

  17. Airflow-Restricting Mask Reduces Acute Performance in Resistance Exercise

    Directory of Open Access Journals (Sweden)

    Yuri L. Motoyama

    2016-09-01

    Full Text Available Background: The aim of this study was to compare the number of repetitions to volitional failure, the blood lactate concentration, and the perceived exertion to resistance training with and without an airflow-restricting mask. Methods: Eight participants participated in a randomized, counterbalanced, crossover study. Participants were assigned to an airflow-restricting mask group (MASK or a control group (CONT and completed five sets of chest presses and parallel squats until failure at 75% one-repetition-maximum test (1RM with 60 s of rest between sets. Ratings of perceived exertion (RPEs, blood lactate concentrations (Lac−, and total repetitions were taken after the training session. Results: MASK total repetitions were lower than those of the CONT, and (Lac− and MASK RPEs were higher than those of the CONT in both exercises. Conclusions: We conclude that an airflow-restricting mask in combination with resistance training increase perceptions of exertion and decrease muscular performance and lactate concentrations when compared to resistance training without this accessory. This evidence shows that the airflow-restricting mask may change the central nervous system and stop the exercise beforehand to prevent some biological damage.

  18. MASKED AREAS IN SHEAR PEAK STATISTICS: A FORWARD MODELING APPROACH

    International Nuclear Information System (INIS)

    Bard, D.; Kratochvil, J. M.; Dawson, W.

    2016-01-01

    The statistics of shear peaks have been shown to provide valuable cosmological information beyond the power spectrum, and will be an important constraint of models of cosmology in forthcoming astronomical surveys. Surveys include masked areas due to bright stars, bad pixels etc., which must be accounted for in producing constraints on cosmology from shear maps. We advocate a forward-modeling approach, where the impacts of masking and other survey artifacts are accounted for in the theoretical prediction of cosmological parameters, rather than correcting survey data to remove them. We use masks based on the Deep Lens Survey, and explore the impact of up to 37% of the survey area being masked on LSST and DES-scale surveys. By reconstructing maps of aperture mass the masking effect is smoothed out, resulting in up to 14% smaller statistical uncertainties compared to simply reducing the survey area by the masked area. We show that, even in the presence of large survey masks, the bias in cosmological parameter estimation produced in the forward-modeling process is ≈1%, dominated by bias caused by limited simulation volume. We also explore how this potential bias scales with survey area and evaluate how much small survey areas are impacted by the differences in cosmological structure in the data and simulated volumes, due to cosmic variance

  19. Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

    Science.gov (United States)

    Newman, Kevin Edward; Belikov, Ruslan; Guyon, Olivier; Balasubramanian, Kunjithapatham; Wilson, Dan

    2013-01-01

    Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

  20. New method of contour-based mask-shape compiler

    Science.gov (United States)

    Matsuoka, Ryoichi; Sugiyama, Akiyuki; Onizawa, Akira; Sato, Hidetoshi; Toyoda, Yasutaka

    2007-10-01

    We have developed a new method of accurately profiling a mask shape by utilizing a Mask CD-SEM. The method is intended to realize high accuracy, stability and reproducibility of the Mask CD-SEM adopting an edge detection algorithm as the key technology used in CD-SEM for high accuracy CD measurement. In comparison with a conventional image processing method for contour profiling, it is possible to create the profiles with much higher accuracy which is comparable with CD-SEM for semiconductor device CD measurement. In this report, we will introduce the algorithm in general, the experimental results and the application in practice. As shrinkage of design rule for semiconductor device has further advanced, an aggressive OPC (Optical Proximity Correction) is indispensable in RET (Resolution Enhancement Technology). From the view point of DFM (Design for Manufacturability), a dramatic increase of data processing cost for advanced MDP (Mask Data Preparation) for instance and surge of mask making cost have become a big concern to the device manufacturers. In a sense, it is a trade-off between the high accuracy RET and the mask production cost, while it gives a significant impact on the semiconductor market centered around the mask business. To cope with the problem, we propose the best method for a DFM solution in which two dimensional data are extracted for an error free practical simulation by precise reproduction of a real mask shape in addition to the mask data simulation. The flow centering around the design data is fully automated and provides an environment where optimization and verification for fully automated model calibration with much less error is available. It also allows complete consolidation of input and output functions with an EDA system by constructing a design data oriented system structure. This method therefore is regarded as a strategic DFM approach in the semiconductor metrology.

  1. Comparison of Aerosol Delivery by Face Mask and Tracheostomy Collar.

    Science.gov (United States)

    Bugis, Alaa A; Sheard, Meryl M; Fink, James B; Harwood, Robert J; Ari, Arzu

    2015-09-01

    The purpose of this study was to compare the performance of a tracheostomy collar, Wright mask, and aerosol mask attached to a jet nebulizer in facilitating aerosolized medication delivery to the lungs. We also compared albuterol delivery with open versus closed fenestration and determined the effect of inspiratory-expiratory ratio (I:E) on aerosol delivery. Albuterol (2.5 mg/3 mL) was administered to an in vitro model consisting of an adult teaching mannequin extrathoracic and upper airway with stoma intubated with an 8-mm fenestrated tracheostomy tube. The cuff was deflated. A collecting filter at the level of the bronchi was connected to a breathing simulator at a tidal volume of 400 mL, breathing frequency of 20 breaths/min, and I:E of 2:1 and 1:2. A jet nebulizer was operated with O2 at 8 L/min. Each interface was tested in triplicate. The flow was discontinued at the end of nebulization. For each test, the nebulizer was attached to a tracheostomy collar with the fenestration open or closed, a Wright mask, or an aerosol mask. Drug was analyzed by spectrophotometry (276 nm). A paired t test and analysis of variance were performed (P mask (4.1 ± 0.6%) and aerosol mask (3.5 ± 0.04%) were both less than with the tracheostomy collar under either condition (P mask (7.2 ± 0.6%), and aerosol mask (6.1 ± 0.5%). In an adult tracheostomy model, the tracheostomy collar delivered more aerosol to the bronchi than the Wright or aerosol mask. An I:E of 2:1 caused greater aerosol deposition compared with an I:E of 1:2. During aerosol administration via a tracheostomy collar, closing the fenestration improved aerosol delivery. Copyright © 2015 by Daedalus Enterprises.

  2. Overcoming Multidrug Resistance in Cancer Stem Cells

    Directory of Open Access Journals (Sweden)

    Karobi Moitra

    2015-01-01

    Full Text Available The principle mechanism of protection of stem cells is through the expression of ATP-binding cassette (ABC transporters. These transporters serve as the guardians of the stem cell population in the body. Unfortunately these very same ABC efflux pumps afford protection to cancer stem cells in tumors, shielding them from the adverse effects of chemotherapy. A number of strategies to circumvent the function of these transporters in cancer stem cells are currently under investigation. These strategies include the development of competitive and allosteric modulators, nanoparticle mediated delivery of inhibitors, targeted transcriptional regulation of ABC transporters, miRNA mediated inhibition, and targeting of signaling pathways that modulate ABC transporters. The role of ABC transporters in cancer stem cells will be explored in this paper and strategies aimed at overcoming drug resistance caused by these particular transporters will also be discussed.

  3. Overcoming Obstacles to Drug Repositioning in Japan

    Directory of Open Access Journals (Sweden)

    Yuhei Nishimura

    2017-10-01

    Full Text Available Drug repositioning (DR is the process of identifying new indications for existing drugs. DR usually focuses on drugs that have cleared phase-I safety trials but has yet to show efficacy for the intended indication. Therefore, DR can probably skip the preclinical and phase-I study, which can reduce the cost throughout drug development. However, the expensive phase-II/III trials are required to establish efficacy. The obstacles to DR include identification of new indications with a high success rate in clinical studies, obtaining funding for clinical studies, patent protection, and approval systems. To tackle these obstacles, various approaches have been applied to DR worldwide. In this perspective, we provide representative examples of DR and discuss the ongoing efforts to overcome obstacles to DR in Japan.

  4. Towards overcoming poor readership and building reading culture ...

    African Journals Online (AJOL)

    Towards overcoming poor readership and building reading culture of in schools. ... of this paper is to find strategies that can overcome poor readership in schools. ... Keywords: English First Additional Language, Writing Skills, Spelling Errors, ...

  5. Integration of mask and silicon metrology in DFM

    Science.gov (United States)

    Matsuoka, Ryoichi; Mito, Hiroaki; Sugiyama, Akiyuki; Toyoda, Yasutaka

    2009-03-01

    We have developed a highly integrated method of mask and silicon metrology. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. We have inspected the high accuracy, stability and reproducibility in the experiments of integration. The accuracy is comparable with that of the mask and silicon CD-SEM metrology. In this report, we introduce the experimental results and the application. As shrinkage of design rule for semiconductor device advances, OPC (Optical Proximity Correction) goes aggressively dense in RET (Resolution Enhancement Technology). However, from the view point of DFM (Design for Manufacturability), the cost of data process for advanced MDP (Mask Data Preparation) and mask producing is a problem. Such trade-off between RET and mask producing is a big issue in semiconductor market especially in mask business. Seeing silicon device production process, information sharing is not completely organized between design section and production section. Design data created with OPC and MDP should be linked to process control on production. But design data and process control data are optimized independently. Thus, we provided a solution of DFM: advanced integration of mask metrology and silicon metrology. The system we propose here is composed of followings. 1) Design based recipe creation: Specify patterns on the design data for metrology. This step is fully automated since they are interfaced with hot spot coordinate information detected by various verification methods. 2) Design based image acquisition: Acquire the images of mask and silicon automatically by a recipe based on the pattern design of CD-SEM.It is a robust automated step because a wide range of design data is used for the image acquisition. 3) Contour profiling and GDS data generation: An image profiling process is applied to the acquired image based

  6. Aperture Mask for Unambiguous Parity Determination in Long Wavelength Imagers

    Science.gov (United States)

    Bos, Brent

    2011-01-01

    A document discusses a new parity pupil mask design that allows users to unambiguously determine the image space coordinate system of all the James Webb Space Telescope (JWST) science instruments by using two out-of-focus images. This is an improvement over existing mask designs that could not completely eliminate the coordinate system parity ambiguity at a wavelength of 5.6 microns. To mitigate the problem of how the presence of diffraction artifacts can obscure the pupil mask detail, this innovation has been created with specifically designed edge features so that the image space coordinate system parity can be determined in the presence of diffraction, even at long wavelengths.

  7. Propagation of resist heating mask error to wafer level

    Science.gov (United States)

    Babin, S. V.; Karklin, Linard

    2006-10-01

    As technology is approaching 45 nm and below the IC industry is experiencing a severe product yield hit due to rapidly shrinking process windows and unavoidable manufacturing process variations. Current EDA tools are unable by their nature to deliver optimized and process-centered designs that call for 'post design' localized layout optimization DFM tools. To evaluate the impact of different manufacturing process variations on final product it is important to trace and evaluate all errors through design to manufacturing flow. Photo mask is one of the critical parts of this flow, and special attention should be paid to photo mask manufacturing process and especially to mask tight CD control. Electron beam lithography (EBL) is a major technique which is used for fabrication of high-end photo masks. During the writing process, resist heating is one of the sources for mask CD variations. Electron energy is released in the mask body mainly as heat, leading to significant temperature fluctuations in local areas. The temperature fluctuations cause changes in resist sensitivity, which in turn leads to CD variations. These CD variations depend on mask writing speed, order of exposure, pattern density and its distribution. Recent measurements revealed up to 45 nm CD variation on the mask when using ZEP resist. The resist heating problem with CAR resists is significantly smaller compared to other types of resists. This is partially due to higher resist sensitivity and the lower exposure dose required. However, there is no data yet showing CD errors on the wafer induced by CAR resist heating on the mask. This effect can be amplified by high MEEF values and should be carefully evaluated at 45nm and below technology nodes where tight CD control is required. In this paper, we simulated CD variation on the mask due to resist heating; then a mask pattern with the heating error was transferred onto the wafer. So, a CD error on the wafer was evaluated subject to only one term of the

  8. Rheumatic masks of plasma cell dyscrasias

    Directory of Open Access Journals (Sweden)

    Vladimir Ivanovich Vasilyev

    2012-01-01

    Full Text Available Objective: to consider clinical practice problems in the differential diagnosis of different types of plasma cell dyscrasias (PCD. Subjects and methods. Fourteen patients (8 men and 6 women aged 52±12 years, in whom rheumatic diseases (RD were ruled out and who were diagnosed as having primary PCD: different types of myeloma in 7 patients, myeloma + AL-amyloidosis in 2, AL-amyloidosis in 3, and Waldenstrom’s macroglobulinemia in 2, were examined. Results and discussion. The most common maldiagnosed RDs in patients with PCD were seronegative rheumatoid arthritis (RA, systemic lupus erythematosus, Sjogren’s disease, and different forms of vasculitis. The most frequent masks of RD were kidney (78% and osteoarticular system (64% lesions, vascular disorders (36%, peripheral polyneuropathies (36%, and enlarged salivary glands with xerostomia (28.5%. Serum and urine immunochemical study should be performed in all patients who have clinical manifestations of seropositive RA, spondyloarthritis, intensive bone pain syndrome, ulceronecrotic vasculitis, enlarged submandibular salivary glands with macroglossia in the absence of markers of autoimmune disease for the timely diagnosis of PCD and the exclusion of RD. The paper estimates the sensitivity and specificity of main methods used to diagnose different types of PCD.

  9. Addressing terrain masking in orbital reconnaissance

    Science.gov (United States)

    Mehta, Sharad; Cico, Luke

    2012-06-01

    During aerial orbital reconnaissance, a sensor system is mounted on an airborne platform for imaging a region on the ground. The latency between the image acquisition and delivery of information to the end-user is critical and must be minimized. Due to fine ground pixel resolution and a large field-of-view for wide-area surveillance applications, a massive volume of data is gathered and imagery products are formed using a real-time multi-processor system. The images are taken at oblique angles, stabilized and ortho-rectified. The line-of-sight of the sensor to the ground is often interrupted by terrain features such as mountains or tall structures as depicted in Figure1. The ortho-rectification process renders the areas hidden from the line-of sight of the sensor with spurious information. This paper discusses an approach for addressing terrain masking in size, weight, and power (SWaP) and memory-restricted onboard processing systems.

  10. Laser etching of polymer masked leadframes

    Science.gov (United States)

    Ho, C. K.; Man, H. C.; Yue, T. M.; Yuen, C. W.

    1997-02-01

    A typical electroplating production line for the deposition of silver pattern on copper leadframes in the semiconductor industry involves twenty to twenty five steps of cleaning, pickling, plating, stripping etc. This complex production process occupies large floor space and has also a number of problems such as difficulty in the production of rubber masks and alignment, generation of toxic fumes, high cost of water consumption and sometimes uncertainty on the cleanliness of the surfaces to be plated. A novel laser patterning process is proposed in this paper which can replace many steps in the existing electroplating line. The proposed process involves the application of high speed laser etching techniques on leadframes which were protected with polymer coating. The desired pattern for silver electroplating is produced by laser ablation of the polymer coating. Excimer laser was found to be most effective for this process as it can expose a pattern of clean copper substrate which can be silver plated successfully. Previous working of Nd:YAG laser ablation showed that 1.06 μm radiation was not suitable for this etching process because a thin organic and transparent film remained on the laser etched region. The effect of excimer pulse frequency and energy density upon the removal rate of the polymer coating was studied.

  11. Infrared Signature Masking by Air Plasma Radiation

    Science.gov (United States)

    Kruger, Charles H.; Laux, C. O.

    2001-01-01

    This report summarizes the results obtained during a research program on the infrared radiation of air plasmas conducted in the High Temperature Gasdynamics Laboratory at Stanford University under the direction of Professor Charles H. Kruger, with Dr. Christophe O. Laux as Associate Investigator. The goal of this research was to investigate the masking of infrared signatures by the air plasma formed behind the bow shock of high velocity missiles. To this end, spectral measurements and modeling were made of the radiation emitted between 2.4 and 5.5 micrometers by an atmospheric pressure air plasma in chemical and thermal equilibrium at a temperature of approximately 3000 K. The objective was to examine the spectral emission of air species including nitric oxide, atomic oxygen and nitrogen lines, molecular and atomic continua, as well as secondary species such as water vapor or carbon dioxide. The cold air stream injected in the plasma torch contained approximately 330 parts per million of CO2, which is the natural CO2 concentration in atmospheric air at room temperatures, and a small amount of water vapor with an estimated mole fraction of 3.8x10(exp -4).

  12. Optimized furosemide taste masked orally disintegrating tablets

    Directory of Open Access Journals (Sweden)

    Mohamed Abbas Ibrahim

    2017-11-01

    Full Text Available Optimized orally disintegrating tablets (ODTs containing furosemide (FUR were prepared by direct compression method. Two factors, three levels (32 full factorial design was used to optimize the effect of taste masking agent (Eudragit E100; X1 and superdisintegarant; croscarmellose sodium (CCS; X2 on tablet properties. A composite was prepared by mixing ethanolic solution of FUR and Eudragit E100 with mannitol prior to mixing with other tablet ingredients. The prepared ODTs were characterized for their FUR content, hardness, friability and wetting time. The optimized ODT formulation (F1 was evaluated in term of palatability parameters and the in vivo disintegration. The manufactured ODTs were complying with the pharmacopeia guidelines regarding hardness, friability, weight variation and content. Eudragit E100 had a very slightly enhancing effect on tablets disintegration. However, the effects of both Eudragit E100 (X1 and CCS (X2 on ODTs disintegration time (Y1 were insignificant (p > 0.05. Moreover, X1 exhibited antagonistic effect on the dissolution after 5 and 30 min (D5 and D30, respectively, but only its effect on D30 is significant (p = 0.0004. Furthermore, the optimized ODTs formula showed good to acceptable taste in term of palatability, and in vivo disintegration time of this formula was about 10 s.

  13. Mini-review: Strategies for Variation and Evolution of Bacterial Antigens

    Science.gov (United States)

    Foley, Janet

    2015-01-01

    Across the eubacteria, antigenic variation has emerged as a strategy to evade host immunity. However, phenotypic variation in some of these antigens also allows the bacteria to exploit variable host niches as well. The specific mechanisms are not shared-derived characters although there is considerable convergent evolution and numerous commonalities reflecting considerations of natural selection and biochemical restraints. Unlike in viruses, mechanisms of antigenic variation in most bacteria involve larger DNA movement such as gene conversion or DNA rearrangement, although some antigens vary due to point mutations or modified transcriptional regulation. The convergent evolution that promotes antigenic variation integrates various evolutionary forces: these include mutations underlying variant production; drift which could remove alleles especially early in infection or during life history phases in arthropod vectors (when the bacterial population size goes through a bottleneck); selection not only for any particular variant but also for the mechanism for the production of variants (i.e., selection for mutability); and overcoming negative selection against variant production. This review highlights the complexities of drivers of antigenic variation, in particular extending evaluation beyond the commonly cited theory of immune evasion. A deeper understanding of the diversity of purpose and mechanisms of antigenic variation in bacteria will contribute to greater insight into bacterial pathogenesis, ecology and coevolution with hosts. PMID:26288700

  14. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?

    Science.gov (United States)

    Tracy, Mark Brian; Priyadarshi, Archana; Goel, Dimple; Lowe, Krista; Huvanandana, Jacqueline; Hinder, Murray

    2018-05-01

    International neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks' gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison. To compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB). 40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH 2 O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV. 12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5-65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH 2 O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3-22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH 2 O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6-2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use. This study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. An optimized OPC and MDP flow for reducing mask write time and mask cost

    Science.gov (United States)

    Yang, Ellyn; Li, Cheng He; Park, Se Jin; Zhu, Yu; Guo, Eric

    2010-09-01

    In the process of optical proximity correction, layout edge or fragment is migrating to proper position in order to minimize edge placement error (EPE). During this fragment migration, several factors other than EPE can be also taken into account as a part of cost function for optimal fragment displacement. Several factors are devised in favor of OPC stability, which can accommodate room for high mask error enhancement factor (MEEF), lack of process window, catastrophic pattern failure such as pinch/bridge and improper fragmentation. As technology node becomes finer, there happens conflict between OPC accuracy and stability. Especially for metal layers, OPC has focused on the stability by loss of accurate OPC results. On this purpose, several techniques have been introduced, which are target smoothing, process window aware OPC, model-based retargeting and adaptive OPC. By utilizing those techniques, OPC enables more stabilized patterning, instead of realizing design target exactly on wafer. Inevitably, post-OPC layouts become more complicated because those techniques invoke additional edge, or fragments prior to correction or during OPC iteration. As a result, jogs of post OPC layer can be dramatically increased, which results in huge number of shot count after data fracturing. In other words, there is trade-off relationship between data complexity and various methods for OPC stability. In this paper, those relationships have been investigated with respect to several technology nodes. The mask shot count reduction is achieved by reducing the number of jogs with which EPE difference are within pre-specified value. The effect of jog smoothing on OPC output - in view of OPC performance and mask data preparation - was studied quantitatively for respective technology nodes.

  16. Chemoselective ligation and antigen vectorization.

    Science.gov (United States)

    Gras-Masse, H

    2001-01-01

    The interest in cocktail-lipopeptide vaccines has now been confirmed by phase I clinical trials: highly diversified B-, T-helper or cytotoxic T-cell epitopes can be combined with a lipophilic vector for the induction of B- and T-cell responses of predetermined specificity. With the goal of producing an improved vaccine that should ideally induce a multispecific response in non-selected populations, increasing the diversity of the immunizing mixture represents one of the most obvious strategies.The selective delivery of antigens to professional antigen-presenting cells represents another promising approach for the improvement of vaccine efficacy. In this context, the mannose-receptor represents an attractive entry point for the targeting to dendritic cells of antigens linked to clustered glycosides or glycomimetics. In all cases, highly complex but fully characterized molecules must be produced. To develop a modular and flexible strategy which could be generally applicable to a large set of peptide antigens, we elected to explore the potentialities of chemoselective ligation methods. The hydrazone bond was found particularly reliable and fully compatible with sulphide ligation. Hydrazone/thioether orthogonal ligation systems could be developed to account for the nature of the antigens and the solubility of the vector systems. Copyright 2001 The International Association for Biologicals.

  17. X-ray face mask and bib device

    International Nuclear Information System (INIS)

    Forshee, D.J.

    1982-01-01

    An x-ray protective face mask is made of a relatively transparent lead containing radiation shielding plastics material, and is removably attachable to a chest or bib shield for application of the device to and support upon the shoulders of a technician or a patient. Alternatively, the face mask is formed of a lens portion supported in a plastics frame, upon the lower portion of which is removably attached a bib shield that in turn is removably attachable to an apron. The frame of the face mask, bib shield and apron are preferably lined with lead sheets to protect the neck, face, chest and body of the technician from the random secondary or scatter x-ray beams. The face mask and bib shield can be formed of a moulded plastics material as a unitary device, the lens portion being attached to the frame therefor. (author)

  18. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  19. Backward masking, the suffix effect, and preperceptual storage.

    Science.gov (United States)

    Kallman, H J; Massaro, D W

    1983-04-01

    This article considers the use of auditory backward recognition masking (ABRM) and stimulus suffix experiments as indexes of preperceptual auditory storage. In the first part of the article, two ABRM experiments that failed to demonstrate a mask disinhibition effect found previously in stimulus suffix experiments are reported. The failure to demonstrate mask disinhibition is inconsistent with an explanation of ABRM in terms of lateral inhibition. In the second part of the article, evidence is presented to support the conclusion that the suffix effect involves the contributions of later processing stages and does not provide an uncontaminated index of preperceptual storage. In contrast, it is claimed that ABRM experiments provide the most direct index of the temporal course of perceptual recognition. Partial-report tasks and other paradigms are also evaluated in terms of their contributions to an understanding of preperceptual auditory storage. Differences between interruption and integration masking are discussed along with the role of preperceptual auditory storage in speech perception.

  20. Kuldne Mask Tallinnasssssss! / Sergei Zhenovatsh ; interv. Hellar Bergmann

    Index Scriptorium Estoniae

    Zhenovatsh, Sergei

    2008-01-01

    Lavastaja Sergei Zhenovatsh oma Teatrikunsti Stuudiost, noortest näitlejatest, Eestist. Lavastaja on Eestis teatrifestivali "Kuldne mask Eestis" raames. 10.-11. okt. etendus Tallinnas, Salme Kultuurikeskuses Nikolai Gogoli näidend "Mängurid"

  1. Thermal stress analysis of the SLAC moveable mask. Addendum 2

    International Nuclear Information System (INIS)

    Johnson, G.L.

    1985-01-01

    X-ray beams emerging from the new SLAC electron-positron storage ring (PEP) can impinge on the walls of tangential divertor channels. A moveable mask made of 6061-T6 aluminum is installed in the channel to limit wall heating. The mask is cooled with water flowing axially at 30 0 C. Beam strikes on the mask cause highly localized heating in the channel structure. Analyses were completed to determine the temperatures and thermally-induced stresses due to this heating. The current design and operating conditions should result in the entrance to the moveable mask operating at a peak temperature of 88 0 C with a peak thermal stress at 19% of the yield of 6061-T6 aluminum

  2. Investigation and modeling of CPL mask profiles using OCD

    Science.gov (United States)

    Chen, Hsuan-Chen; Lin, Ren-Hao; Chen, Chien-Cheng; Huang, Cheng-Hsuan; Lien, Ta-Cheng; Chen, Chia-Jen; Lee, Gaston; Lee, Hsin-Chang; Yen, Anthony

    2016-05-01

    Mask profile of chromeless phase-shifting lithography (CPL) defined by OCD has been investigated. In CPL masks, unbalanced bombardments caused by different ion accelerations lead to the formation of micro-notch structures. A better understanding of micro-notch structures is essential for quality gating of mask processes to improve of CPL mask profiles. By measuring 12 of 16 elements of Mueller matrix, we are able to set up a model to simulate the depth of micro-notch structure profile which shows good correlation with TEM images. Moreover, values of CD, quartz etching depth and side wall angle acquired by OCD are presented and compared with those obtained by SEM, TEM and AFM, respectively.

  3. Comparison of bougie-guided insertion of Proseal tm laryngeal mask airway with digital technique in adults

    Directory of Open Access Journals (Sweden)

    Anand Kuppusamy

    2010-01-01

    Full Text Available The Proseal TM laryngeal mask airway (PLMA TM , Laryngeal Mask Company, UK was designed to improve ventilatory characteristics and offer protection against regurgitation and gastric insufflation. The PLMA is a modified laryngeal mask airway with large ventral cuff, dorsal cuff and a drain tube. These modifications improve seal around glottis and enable better ventilatory characteristics. The drain tube prevents gastric distension and offers protection against aspiration. There were occasional problems, like failed insertion and inadequate ventilation, in placing PLMA TM using the classical digital technique. To overcome these problems, newer placement techniques like thumb insertion technique, introducer tool placement and gum elastic bougie (GEB-aided placement were devised. We compared classical digital placement of PLMA TM with gum elastic bougie-aided technique in 60 anaesthetised adult patients (with 30 patients in each group with respect to number of attempts to successful placement, effective airway time, airway trauma during insertion, postoperative airway morbidity and haemodynamic response to insertion. The number of attempts to successful placement, airway trauma during insertion and haemodynamic response to insertion were comparable among the two groups, while effective airway time and oropharyngeal leak pressure were significantly higher in bougie- guided insertion of PLMA. Postoperatively, sore throat was more frequent with digital technique while dysphagia was more frequent with bougie-guided technique. Hence gum elastic bougie guided, laryngoscope aided insertion of PLMA is an excellent alternate to classical digital technique.

  4. Noise frame duration, masking potency and whiteness of temporal noise

    OpenAIRE

    Kukkonen, Helja; Rovamo, Jyrki; Donner, Kristian; Tammikallio, Marja; Raninen, Antii

    2002-01-01

    PURPOSE. Because of the limited contrast range, increasing the duration of the noise frame is often the only option for increasing the masking potency of external, white temporal noise. This, however, reduces the high-frequency cutoff beyond which noise is no longer white. This study was conducted to determine the longest noise frame duration that produces the strongest masking effect and still mimics white noise on the detection of sinusoidal flicker. \\ud \\ud METHODS. Contrast energy thresho...

  5. Masking responses to light in period mutant mice.

    Science.gov (United States)

    Pendergast, Julie S; Yamazaki, Shin

    2011-10-01

    Masking is an acute effect of an external signal on an overt rhythm and is distinct from the process of entrainment. In the current study, we investigated the phase dependence and molecular mechanisms regulating masking effects of light pulses on spontaneous locomotor activity in mice. The circadian genes, Period1 (Per1) and Per2, are necessary components of the timekeeping machinery and entrainment by light appears to involve the induction of the expression of Per1 and Per2 mRNAs in the suprachiasmatic nuclei (SCN). We assessed the roles of the Per genes in regulating masking by assessing the effects of light pulses on nocturnal locomotor activity in C57BL/6J Per mutant mice. We found that Per1(-/-) and Per2(-/-) mice had robust negative masking responses to light. In addition, the locomotor activity of Per1(-/-)/Per2(-/-) mice appeared to be rhythmic in the light-dark (LD) cycle, and the phase of activity onset was advanced (but varied among individual mice) relative to lights off. This rhythm persisted for 1 to 2 days in constant darkness in some Per1(-/-)/Per2(-/-) mice. Furthermore, Per1(-/-)/Per2(-/-) mice exhibited robust negative masking responses to light. Negative masking was phase dependent in wild-type mice such that maximal suppression was induced by light pulses at zeitgeber time 14 (ZT14) and gradually weaker suppression occurred during light pulses at ZT16 and ZT18. By measuring the phase shifts induced by the masking protocol (light pulses were administered to mice maintained in the LD cycle), we found that the phase responsiveness of Per mutant mice was altered compared to wild-types. Together, our data suggest that negative masking responses to light are robust in Per mutant mice and that the Per1(-/-)/Per2(-/-) SCN may be a light-driven, weak/damping oscillator.

  6. Bubble masks for time-encoded imaging of fast neutrons.

    Energy Technology Data Exchange (ETDEWEB)

    Brubaker, Erik; Brennan, James S.; Marleau, Peter; Nowack, Aaron B.; Steele, John T.; Sweany, Melinda; Throckmorton, Daniel J.

    2013-09-01

    Time-encoded imaging is an approach to directional radiation detection that is being developed at SNL with a focus on fast neutron directional detection. In this technique, a time modulation of a detected neutron signal is inducedtypically, a moving mask that attenuates neutrons with a time structure that depends on the source position. An important challenge in time-encoded imaging is to develop high-resolution two-dimensional imaging capabilities; building a mechanically moving high-resolution mask presents challenges both theoretical and technical. We have investigated an alternative to mechanical masks that replaces the solid mask with a liquid such as mineral oil. Instead of fixed blocks of solid material that move in pre-defined patterns, the oil is contained in tubing structures, and carefully introduced air gapsbubblespropagate through the tubing, generating moving patterns of oil mask elements and air apertures. Compared to current moving-mask techniques, the bubble mask is simple, since mechanical motion is replaced by gravity-driven bubble propagation; it is flexible, since arbitrary bubble patterns can be generated by a software-controlled valve actuator; and it is potentially high performance, since the tubing and bubble size can be tuned for high-resolution imaging requirements. We have built and tested various single-tube mask elements, and will present results on bubble introduction and propagation as a function of tubing size and cross-sectional shape; real-time bubble position tracking; neutron source imaging tests; and reconstruction techniques demonstrated on simple test data as well as a simulated full detector system.

  7. Evaluation of the Joint Service General Purpose Mask, XM50

    Science.gov (United States)

    2005-07-01

    and vision Trial 7 Trial 8 Trial 12 correction E-2 TRIAL 3299 7795 2079 Did not finish exercises. No No comment on sweat or No comment on sweat or...lhr 50 min playing time). Duringboth activities, slight Reported slight intermittent No comment on. swet or fogging with slight impact on fogging...right eye. During steam No comment on Mask was stationary. engine exercise, reported 4 sweat or fogging Reported that seal mask seal leakage at

  8. Differential effect of visual masking in perceptual categorization.

    Science.gov (United States)

    Hélie, Sébastien; Cousineau, Denis

    2015-06-01

    This article explores the visual information used to categorize stimuli drawn from a common stimulus space into verbal and nonverbal categories using 2 experiments. Experiment 1 explores the effect of target duration on verbal and nonverbal categorization using backward masking to interrupt visual processing. With categories equated for difficulty for long and short target durations, intermediate target duration shows an advantage for verbal categorization over nonverbal categorization. Experiment 2 tests whether the results of Experiment 1 can be explained by shorter target duration resulting in a smaller signal-to-noise ratio of the categorization stimulus. To test for this possibility, Experiment 2 used integration masking with the same stimuli, categories, and masks as Experiment 1 with a varying level of mask opacity. As predicted, low mask opacity yielded similar results to long target duration while high mask opacity yielded similar results to short target duration. Importantly, intermediate mask opacity produced an advantage for verbal categorization over nonverbal categorization, similar to intermediate target duration. These results suggest that verbal and nonverbal categorization are affected differently by manipulations affecting the signal-to-noise ratio of the stimulus, consistent with multiple-system theories of categorizations. The results further suggest that verbal categorization may be more digital (and more robust to low signal-to-noise ratio) while the information used in nonverbal categorization may be more analog (and less robust to lower signal-to-noise ratio). This article concludes with a discussion of how these new results affect the use of masking in perceptual categorization and multiple-system theories of perceptual category learning. (c) 2015 APA, all rights reserved).

  9. Adapting Mask-RCNN for Automatic Nucleus Segmentation

    OpenAIRE

    Johnson, Jeremiah W.

    2018-01-01

    Automatic segmentation of microscopy images is an important task in medical image processing and analysis. Nucleus detection is an important example of this task. Mask-RCNN is a recently proposed state-of-the-art algorithm for object detection, object localization, and object instance segmentation of natural images. In this paper we demonstrate that Mask-RCNN can be used to perform highly effective and efficient automatic segmentations of a wide range of microscopy images of cell nuclei, for ...

  10. A phase mask fiber grating and sensing applications

    Directory of Open Access Journals (Sweden)

    Preecha P. Yupapin

    2003-09-01

    Full Text Available This paper presents an investigation of a fabricated fiber grating device characteristics and its applications, using a phase mask writing technique. The use of a most common UV phase laser (KrF eximer laser, with high intensity light source was focussed to the phase mask for writing on a fiber optic sample. The device (i.e. grating characteristic especially, in sensing application, was investigated. The possibility of using such device for temperature and strain sensors is discussed.

  11. Protection provided by masks sinkers in interventional techniques

    International Nuclear Information System (INIS)

    Pera Cegarra, O.; Alejo Luque, L.; Pifarre Martinez, J.

    2011-01-01

    The high doses that are taught in laboratories worked indispensable the use of shields and armor. In this context, the use of sinkers glasses is widespread, but not the sinkers of the masks. Qur goal is to study the effectiveness of such masks for later comparison with that provided by leaded glasses with side shields. Specifically, compare the reduction in lens dose rate for different positions and orientations of the head of specialist intervention.

  12. Masked hypertension: evaluation, prognosis, and treatment.

    Science.gov (United States)

    Angeli, Fabio; Reboldi, Gianpaolo; Verdecchia, Paolo

    2010-09-01

    Blood pressure (BP) may be high during usual daily life in one out of 7-8 individuals with normal BP in the clinic or doctor's office. This condition is usually defined as masked hypertension (MH). Prevalence of MH varied across different studies depending on patient characteristics, populations studied, and different definitions of MH. Self-measured BP and ambulatory BP (ABP) have been widely used to identify subjects with MH. Various factors have been identified as possible determinants of MH. Cigarette smoking, alcohol, physical activity, job, and psychological stress may increase BP out of the clinical environment in otherwise normotensive individuals, leading to MH. In most studies, target organ damage was comparable in subjects with MH and those with sustained hypertension, and greater than in those with true normotension. Subjects with MH showed a 1.5- to 3-fold higher risk of major cardiovascular (CV) disease than those with normotension, and their risk was not different from that of patients with sustained hypertension. In an overview of literature, we found that the risk of major CV disease was higher in subjects with MH than in the normotensive subjects regardless of the definition of MH based on self-measured BP (hazard ratio (HR) 2.13; 95% confidence interval (CI): 1.35-3.35; P = 0.001) or 24-h ABP (HR 2.00; 95% CI: 1.54-2.60; P who appear to be more likely to have this condition. Antihypertensive treatment is envisaged in these subjects, although the associated outcome benefits are still undetermined.

  13. Comparison of the OxyMask and Venturi Mask in the Delivery of Supplemental Oxygen: Pilot Study in Oxygen-Dependent Patients

    OpenAIRE

    Beecroft, Jaime M; Hanly, Patrick J

    2006-01-01

    BACKGROUND: The OxyMask (Southmedic Inc, Canada) is a new face mask for oxygen delivery that uses a small ‘diffuser’ to concentrate and direct oxygen toward the mouth and nose. The authors hypothesized that this unique design would enable the OxyMask to deliver oxygen more efficiently than a Venturi mask (Hudson RCI, USA) in patients with chronic hypoxemia.METHODS: Oxygen-dependent patients with chronic, stable respiratory disease were recruited to compare the OxyMask and Venturi mask in a ra...

  14. Imperceptible reversible watermarking of radiographic images based on quantum noise masking.

    Science.gov (United States)

    Pan, Wei; Bouslimi, Dalel; Karasad, Mohamed; Cozic, Michel; Coatrieux, Gouenou

    2018-07-01

    Advances in information and communication technologies boost the sharing and remote access to medical images. Along with this evolution, needs in terms of data security are also increased. Watermarking can contribute to better protect images by dissimulating into their pixels some security attributes (e.g., digital signature, user identifier). But, to take full advantage of this technology in healthcare, one key problem to address is to ensure that the image distortion induced by the watermarking process does not endanger the image diagnosis value. To overcome this issue, reversible watermarking is one solution. It allows watermark removal with the exact recovery of the image. Unfortunately, reversibility does not mean that imperceptibility constraints are relaxed. Indeed, once the watermark removed, the image is unprotected. It is thus important to ensure the invisibility of reversible watermark in order to ensure a permanent image protection. We propose a new fragile reversible watermarking scheme for digital radiographic images, the main originality of which stands in masking a reversible watermark into the image quantum noise (the dominant noise in radiographic images). More clearly, in order to ensure the watermark imperceptibility, our scheme differentiates the image black background, where message embedding is conducted into pixel gray values with the well-known histogram shifting (HS) modulation, from the anatomical object, where HS is applied to wavelet detail coefficients, masking the watermark with the image quantum noise. In order to maintain the watermark embedder and reader synchronized in terms of image partitioning and insertion domain, our scheme makes use of different classification processes that are invariant to message embedding. We provide the theoretical performance limits of our scheme into the image quantum noise in terms of image distortion and message size (i.e. capacity). Experiments conducted on more than 800 12 bits radiographic images

  15. A pattern-based method to automate mask inspection files

    Science.gov (United States)

    Kamal Baharin, Ezni Aznida Binti; Muhsain, Mohamad Fahmi Bin; Ahmad Ibrahim, Muhamad Asraf Bin; Ahmad Noorhani, Ahmad Nurul Ihsan Bin; Sweis, Jason; Lai, Ya-Chieh; Hurat, Philippe

    2017-03-01

    Mask inspection is a critical step in the mask manufacturing process in order to ensure all dimensions printed are within the needed tolerances. This becomes even more challenging as the device nodes shrink and the complexity of the tapeout increases. Thus, the amount of measurement points and their critical dimension (CD) types are increasing to ensure the quality of the mask. In addition to the mask quality, there is a significant amount of manpower needed when the preparation and debugging of this process are not automated. By utilizing a novel pattern search technology with the ability to measure and report match region scan-line (edge) measurements, we can create a flow to find, measure and mark all metrology locations of interest and provide this automated report to the mask shop for inspection. A digital library is created based on the technology product and node which contains the test patterns to be measured. This paper will discuss how these digital libraries will be generated and then utilized. As a time-critical part of the manufacturing process, this can also reduce the data preparation cycle time, minimize the amount of manual/human error in naming and measuring the various locations, reduce the risk of wrong/missing CD locations, and reduce the amount of manpower needed overall. We will also review an example pattern and how the reporting structure to the mask shop can be processed. This entire process can now be fully automated.

  16. Mask design and fabrication in coded aperture imaging

    International Nuclear Information System (INIS)

    Shutler, Paul M.E.; Springham, Stuart V.; Talebitaher, Alireza

    2013-01-01

    We introduce the new concept of a row-spaced mask, where a number of blank rows are interposed between every pair of adjacent rows of holes of a conventional cyclic difference set based coded mask. At the cost of a small loss in signal-to-noise ratio, this can substantially reduce the number of holes required to image extended sources, at the same time increasing mask strength uniformly across the aperture, as well as making the mask automatically self-supporting. We also show that the Finger and Prince construction can be used to wrap any cyclic difference set onto a two-dimensional mask, regardless of the number of its pixels. We use this construction to validate by means of numerical simulations not only the performance of row-spaced masks, but also the pixel padding technique introduced by in ’t Zand. Finally, we provide a computer program CDSGEN.EXE which, on a fast modern computer and for any Singer set of practical size and open fraction, generates the corresponding pattern of holes in seconds

  17. Face mask ventilation--the dos and don'ts.

    Science.gov (United States)

    Wood, Fiona E; Morley, Colin J

    2013-12-01

    Face mask ventilation provides respiratory support to newly born or sick infants. It is a challenging technique and difficult to ensure that an appropriate tidal volume is delivered because large and variable leaks occur between the mask and face; airway obstruction may also occur. Technique is more important than the mask shape although the size must appropriately fit the face. The essence of the technique is to roll the mask on to the face from the chin while avoiding the eyes, with a finger and thumb apply a strong even downward pressure to the top of the mask, away from the stem and sloped sides or skirt of the mask, place the other fingers under the jaw and apply a similar upward pressure. Preterm infants require continuous end-expiratory pressure to facilitate lung aeration and maintain lung volume. This is best done with a T-piece device, not a self-inflating or flow-inflating bag. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. GLEBUS SAINCIUC’S PAPIER-MÂCHÉ PORTRAIT MASKS

    Directory of Open Access Journals (Sweden)

    MARIAN ANA

    2016-12-01

    Full Text Available The portrait masks created by Glebus Sainciuc (1919-2012 portray painters, sculptors, musicians, writers, actors, playwrights,filmmakers etc., and they are a proof of the fact that the individual contribution of these persons to the artistic development of our country has not been forgotten. Morphologically, the papier-mâché portrait masks of master Glebus Sainciuc are situated at the limit of painting, graphic drawing and sculpture; the masks were created by the master using the papier-mâché techniques. We should mention that the author’s predilection for the fauvist and naïve techniques in portrait representation, together with the style of his caricatures and small size drawings, infl uenced the caricatures style of his masks. The first portrait masks were created by Glebus Sainciuc in 1957, and by the end of his artistic activity his collection consisted of 350 masks – all depicting different persons, but all sharing the same portrait techniques and showing the inner charm of these persons.

  19. Status of EUVL mask development in Europe (Invited Paper)

    Science.gov (United States)

    Peters, Jan H.

    2005-06-01

    EUV lithography is the prime candidate for the next generation lithography technology after 193 nm immersion lithography. The commercial onset for this technology is expected for the 45 nm half-pitch technology or below. Several European and national projects and quite a large number of companies and research institutions in Europe work on various aspects of the technological challenges to make EUV a commercially viable technology in the not so far future. Here the development of EUV sources, the development of an EUV exposure tools, metrology tools dedicated for characterization of mask, the production of EUV mask blanks and the mask structuring itself are the key areas in which major activities can be found. In this talk we will primarily focus on those activities, which are related to establish an EUV mask supply chain with all its ingredients from substrate production, polishing, deposition of EUV layers, blank characterization, mask patterning process and the consecutive metrology and defect inspection as well as shipping and handling from blank supply to usage in the wafer fab. The EUV mask related projects on the national level are primarily supported by the French Ministry of Economics and Finance (MinEFi) and the German Ministry of Education and Research (BMBF).

  20. Source Separation via Spectral Masking for Speech Recognition Systems

    Directory of Open Access Journals (Sweden)

    Gustavo Fernandes Rodrigues

    2012-12-01

    Full Text Available In this paper we present an insight into the use of spectral masking techniques in time-frequency domain, as a preprocessing step for the speech signal recognition. Speech recognition systems have their performance negatively affected in noisy environments or in the presence of other speech signals. The limits of these masking techniques for different levels of the signal-to-noise ratio are discussed. We show the robustness of the spectral masking techniques against four types of noise: white, pink, brown and human speech noise (bubble noise. The main contribution of this work is to analyze the performance limits of recognition systems  using spectral masking. We obtain an increase of 18% on the speech hit rate, when the speech signals were corrupted by other speech signals or bubble noise, with different signal-to-noise ratio of approximately 1, 10 and 20 dB. On the other hand, applying the ideal binary masks to mixtures corrupted by white, pink and brown noise, results an average growth of 9% on the speech hit rate, with the same different signal-to-noise ratio. The experimental results suggest that the masking spectral techniques are more suitable for the case when it is applied a bubble noise, which is produced by human speech, than for the case of applying white, pink and brown noise.

  1. Evaluative pressure overcomes perceptual load effects.

    Science.gov (United States)

    Normand, Alice; Autin, Frédérique; Croizet, Jean-Claude

    2015-06-01

    Perceptual load has been found to be a powerful bottom-up determinant of distractibility, with high perceptual load preventing distraction by any irrelevant information. However, when under evaluative pressure, individuals exert top-down attentional control by giving greater weight to task-relevant features, making them more distractible from task-relevant distractors. One study tested whether the top-down modulation of attention under evaluative pressure overcomes the beneficial bottom-up effect of high perceptual load on distraction. Using a response-competition task, we replicated previous findings that high levels of perceptual load suppress task-relevant distractor response interference, but only for participants in a control condition. Participants under evaluative pressure (i.e., who believed their intelligence was assessed) showed interference from task-relevant distractor at all levels of perceptual load. This research challenges the assumptions of the perceptual load theory and sheds light on a neglected determinant of distractibility: the self-relevance of the performance situation in which attentional control is solicited.

  2. Cooperative networks overcoming defectors by social influence

    Science.gov (United States)

    Gomez Portillo, Ignacio

    2014-01-01

    We address the cooperation problem in structured populations by considering the prisoner’s dilemma game as a metaphor of the social interactions between individuals with imitation capacity. We present a new strategy update rule called democratic weighted update where the individual’s behavior is socially influenced by each one of their neighbors. In particular, the capacity of an individual to socially influence other ones is proportional to its accumulated payoff. When in a neighborhood there are cooperators and defectors, the focal player is contradictorily influenced by them and, therefore, the effective social influence is given by the difference of the accumulated payoff of each strategy in its neighborhood. First, by considering the growing process of the network and neglecting mutations, we show the evolution of highly cooperative systems. Then, we broadly show that the social influence allows to overcome the emergence of defectors into highly cooperative systems. In this way, we conclude that in a structured system formed by a growing process, the cooperation evolves if the individuals have an imitation capacity socially influenced by each one of their neighbors. Therefore, here we present a theoretical solution of the cooperation problem among genetically unrelated individuals.

  3. Overcoming soil compaction in surface mine reclamation

    Energy Technology Data Exchange (ETDEWEB)

    Sweigard, R.J. (University of Kentucky, Lexington, KY (USA). Dept. of Mining Engineering)

    1991-01-01

    Rubber-tyred soil reconstruction equipment causes compaction of soil and means surface mine operators cannot satisfy crop yield standards defined by the Surface Mining Control and Reclamation Act. Soil compaction can be overcome by either modifying the reconstruction process or alleviating the problem, for example by deep tillage, once it occurs. The Dept. of Mining Engineering at the Institute of Mining and Minerals Research is conducting a laboratory investigation into a method of injecting low density porous organic material into a bin containing soil at the same time as the soil is ripped. This should prevent voids collapsing when subjected to forces from farm equipment and natural sources. Soil analyses are performed before and after the injection. Ripping and injection with ground pecan shells had a residual effect on nuclear bulk density compared to the initially compacted case and also showed an improvement in hydraulic conductivity. Work is in progress on modifying the system to handle other injection material and should lead on to field tests on a prototype involving both soil analysis and crop yield determination. 1 fig.

  4. Overcoming soil compaction in surface mine reclamation

    International Nuclear Information System (INIS)

    Sweigard, R.J.

    1991-01-01

    Rubber-tyred soil reconstruction equipment causes compaction of soil and means surface mine operators cannot satisfy crop yield standards defined by the Surface Mining Control and Reclamation Act. Soil compaction can be overcome by either modifying the reconstruction process or alleviating the problem, for example by deep tillage, once it occurs. The Dept. of Mining Engineering at the Institute of Mining and Minerals Research is conducting a laboratory investigation into a method of injecting low density porous organic material into a bin containing soil at the same time as the soil is ripped. This should prevent voids collapsing when subjected to forces from farm equipment and natural sources. Soil analyses are performed before and after the injection. Ripping and injection with ground pecan shells had a residual effect on nuclear bulk density compared to the initially compacted case and also showed an improvement in hydraulic conductivity. Work is in progress on modifying the system to handle other injection material and should lead on to field tests on a prototype involving both soil analysis and crop yield determination. 1 fig

  5. Overponderabilia: Overcoming Overthinking When Studying "Ourselves"

    Directory of Open Access Journals (Sweden)

    Kasper Tang Vangkilde

    2016-05-01

    Full Text Available This article discusses a key methodological difficulty in conducting qualitative research close to home: the issue of overthinking. Whereas MALINOWSKI's concern regarding imponderabilia, i.e., the risk of not thinking about the subtle phenomena of everyday life, has long haunted ethnographers and qualitative researchers, not least those working "at home," we highlight an issue of overponderabilia, i.e., the risk of overthinking seemingly familiar statements and practices of the people studied. How do we, as qualitative researchers, study very well-known phenomena such as science, bureaucracy, management etc. without reading our own ideas and understandings into the deceptively familiar concepts and accounts of our research subjects? Pondering this issue is inevitably a central concern for the increasing number of qualitative researchers who study people who apparently talk, think and work in a way which is similar to their own. While previous answers or solutions to this issue first and foremost emphasize various means of reflexivity, this article presents the method of "mutual participatory observation" as a particular way of overcoming overthinking: a method which in situ invites our research subjects into our thinking. Thus, in the pursuit of an ever enhanced understanding, qualitative research becomes not so much a reflexive deciphering as an active debate; that is, a mutual induction of the differences between the qualitative researcher and the research subjects. URN: http://nbn-resolving.de/urn:nbn:de:0114-fqs1602281

  6. Developing an intervention to overcome procrastination.

    Science.gov (United States)

    Otermin-Cristeta, Solange; Hautzinger, Martin

    2018-01-01

    The main goal of this study was the development of a reliable intervention to overcome general procrastination orientated to college students, designed to be used in practical clinical work. The workshops involved six meetings based on behavioral and cognitive techniques, paradox intervention, and psychoeducation. 175 students participated voluntarily. Their procrastination levels were measured in a pretest, post-test, and a 3-month follow-up. After the first interview, the participants were randomly divided into three groups (Intervention A, Intervention B, and a control group with no intervention). There was a significant improvement after the intervention. After 3 months, the average score was still significantly lower than in the pretest, whereas the score of the control group remained unchanged. The participants in Workshop A scored significantly lower in the post-test than the ones in Workshop B. After 3 months, the participants in Workshop B scored significantly lower in the follow up. So both interventions resulted to be effective in reducing procrastination sustainably.

  7. 42 CFR 84.118 - Half-mask facepieces, full facepieces, and mouthpieces; fit; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Half-mask facepieces, full facepieces, and... OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.118 Half-mask facepieces, full facepieces, and mouthpieces; fit; minimum requirements. (a) Half-mask facepieces and full facepieces shall be designed and...

  8. Antigen-antibody reactions of UV-irradiated phage DNA

    International Nuclear Information System (INIS)

    Fink, A.

    1976-01-01

    The observation of others could be confirmed that UV-irradiated DNA is a better immunogen than unirradiated DNA. The author's immune sera contained a high amount of antibodies with a specific action against photoproducts in the DNA. The thymine dimer was identified as relevant photoproduct and thus as antigenic determinant. In comparison, the amount of unspecific antibodies reacting with denaturated DNA was low and varied between sera. Thymin-dimer antibodies showed a high specificity without cross-reaction with other pyrimidine dimers such as anti CC and anti CT; they belong to the class of IgG molecules. UV-irradiated dinucleotide dTpT is sufficient to induce the formation of antibodies reacting with the cis-syn thymine dimers in UV-irradiated DNA. Antibody binding is proportional to the UV doses applied to the DNA. When using completely denaturated DNA, there is a linear increase changing into a plateau at higher doses. The extent of antigen-antibody binding is strongly dependent on the degree of denaturation of the DNA. With increasing denaturation, the antibody binding of the DNA increases. The antigen-antibody reaction can thus be used to estimate the degree of denaturation of the DNA. There were no signs of an influence of the degree of denaturation of the DNA on the quantum yield of thymine dimers. The different amounts of antibodies is therefore due to the masking of thymine dimers in native DNA. When irradiating intact phage particles, there was no sign of an influence of the phages' protein covers on the antibody binding capacity of DNA compared with DNA irradiated in vitro. (orig.) [de

  9. A procedure and program to calculate shuttle mask advantage

    Science.gov (United States)

    Balasinski, A.; Cetin, J.; Kahng, A.; Xu, X.

    2006-10-01

    A well-known recipe for reducing mask cost component in product development is to place non-redundant elements of layout databases related to multiple products on one reticle plate [1,2]. Such reticles are known as multi-product, multi-layer, or, in general, multi-IP masks. The composition of the mask set should minimize not only the layout placement cost, but also the cost of the manufacturing process, design flow setup, and product design and introduction to market. An important factor is the quality check which should be expeditious and enable thorough visual verification to avoid costly modifications once the data is transferred to the mask shop. In this work, in order to enable the layer placement and quality check procedure, we proposed an algorithm where mask layers are first lined up according to the price and field tone [3]. Then, depending on the product die size, expected fab throughput, and scribeline requirements, the subsequent product layers are placed on the masks with different grades. The actual reduction of this concept to practice allowed us to understand the tradeoffs between the automation of layer placement and setup related constraints. For example, the limited options of the numbers of layer per plate dictated by the die size and other design feedback, made us consider layer pairing based not only on the final price of the mask set, but also on the cost of mask design and fab-friendliness. We showed that it may be advantageous to introduce manual layer pairing to ensure that, e.g., all interconnect layers would be placed on the same plate, allowing for easy and simultaneous design fixes. Another enhancement was to allow some flexibility in mixing and matching of the layers such that non-critical ones requiring low mask grade would be placed in a less restrictive way, to reduce the count of orphan layers. In summary, we created a program to automatically propose and visualize shuttle mask architecture for design verification, with

  10. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?

    Science.gov (United States)

    Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey

    2017-08-01

    The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  11. Masking with faces in central visual field under a variety of temporal schedules.

    Science.gov (United States)

    Daar, Marwan; Wilson, Hugh R

    2015-11-01

    With a few exceptions, previous studies have explored masking using either a backward mask or a common onset trailing mask, but not both. In a series of experiments, we demonstrate the use of faces in central visual field as a viable method to study the relationship between these two types of mask schedule. We tested observers in a two alternative forced choice face identification task, where both target and mask comprised synthetic faces, and show that a simple model can successfully predict masking across a variety of masking schedules ranging from a backward mask to a common onset trailing mask and a number of intermediate variations. Our data are well accounted for by a window of sensitivity to mask interference that is centered at around 100 ms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Natural selection promotes antigenic evolvability

    NARCIS (Netherlands)

    Graves, C.J.; Ros, V.I.D.; Stevenson, B.; Sniegowski, P.D.; Brisson, D.

    2013-01-01

    The hypothesis that evolvability - the capacity to evolve by natural selection - is itself the object of natural selection is highly intriguing but remains controversial due in large part to a paucity of direct experimental evidence. The antigenic variation mechanisms of microbial pathogens provide

  13. Mid-Atlantic Wind - Overcoming the Challenges

    Energy Technology Data Exchange (ETDEWEB)

    Daniel F. Ancona III; Kathryn E. George; Richard P. Bowers; Dr. Lynn Sparling; Bruce Buckheit; Daniel LoBue

    2012-05-31

    This study, supported by the US Department of Energy, Wind Powering America Program, Maryland Department of Natural Resources and Chesapeake Bay Foundation, analyzed barriers to wind energy development in the Mid-Atlantic region along with options for overcoming or mitigating them. The Mid-Atlantic States including Delaware, Maryland, North Carolina and Virginia, have excellent wind energy potential and growing demand for electricity, but only two utility-scale projects have been installed to date. Reasons for this apathetic development of wind resources were analyzed and quantified for four markets. Specific applications are: 1) Appalachian mountain ridgeline sites, 2) on coastal plains and peninsulas, 3) at shallow water sites in Delaware and Chesapeake Bays, Albemarle and Pamlico Sounds, and 4) at deeper water sites off the Atlantic coast. Each market has distinctly different opportunities and barriers. The primary barriers to wind development described in this report can be grouped into four categories; state policy and regulatory issues, wind resource technical uncertainty, economic viability, and public interest in environmental issues. The properties of these typologies are not mutually independent and do interact. The report concluded that there are no insurmountable barriers to land-based wind energy projects and they could be economically viable today. Likewise potential sites in sheltered shallow waters in regional bay and sounds have been largely overlooked but could be viable currently. Offshore ocean-based applications face higher costs and technical and wind resource uncertainties. The ongoing research and development program, revision of state incentive policies, additional wind measurement efforts, transmission system expansion, environmental baseline studies and outreach to private developers and stakeholders are needed to reduce barriers to wind energy development.

  14. Mid-Atlantic Wind - Overcoming the Challenges

    Energy Technology Data Exchange (ETDEWEB)

    Daniel F. Ancona III; Kathryn E. George; Lynn Sparling; Bruce C. Buckheit; Daniel LoBue; and Richard P. Bowers

    2012-06-29

    This study, supported by the US Department of Energy, Wind Powering America Program, Maryland Department of Natural Resources and Chesapeake Bay Foundation, analyzed barriers to wind energy development in the Mid-Atlantic region along with options for overcoming or mitigating them. The Mid-Atlantic States including Delaware, Maryland, North Carolina and Virginia, have excellent wind energy potential and growing demand for electricity, but only two utility-scale projects have been installed to date. Reasons for this apathetic development of wind resources were analyzed and quantified for four markets. Specific applications are: 1) Appalachian mountain ridgeline sites, 2) on coastal plains and peninsulas, 3) at shallow water sites in Delaware and Chesapeake Bays, Albemarle and Pamlico Sounds, and 4) at deeper water sites off the Atlantic coast. Each market has distinctly different opportunities and barriers. The primary barriers to wind development described in this report can be grouped into four categories; state policy and regulatory issues, wind resource technical uncertainty, economic viability, and public interest in environmental issues. The properties of these typologies are not mutually independent and do interact. The report concluded that there are no insurmountable barriers to land-based wind energy projects and they could be economically viable today. Likewise potential sites in sheltered shallow waters in regional bay and sounds have been largely overlooked but could be viable currently. Offshore ocean-based applications face higher costs and technical and wind resource uncertainties. The ongoing research and development program, revision of state incentive policies, additional wind measurement efforts, transmission system expansion, environmental baseline studies and outreach to private developers and stakeholders are needed to reduce barriers to wind energy development.

  15. Overcoming the Challenges of Co-creation

    Science.gov (United States)

    Pandya, R.; Udu-gama, N.; Goodwin, M.; Otellini, P.

    2016-12-01

    There is growing interest in co-creation, especially for community-related issues like climate change, resilience, pollution, and environmental justice. Nevertheless, co-creation is still not mainstream practice in either geosciences or the world of decision-makers. This presents many challenges. On the science side, challenges include a paucity of training opportunities, lack of funding for co-creation, difficulty publishing or otherwise getting credit for the effort, and a perceived lack of prestige compared to theoretical research. On the community side, parallel challenges include a lack of experience working with scientists or thinking about geoscience's relevance to community issues, tight budgets and competing priorities, the need for outputs beyond publications, and the difficulty including science among a range of factors. Additionally, scientists and community leaders often work across public and private sectors and must navigate different approaches to data, privacy, and accountability. We'll use this session to explore opportunities to overcome the challenges of co-creation. Systems thinking suggests a range of approaches: enabling individuals, reducing specific challenges, changing the relationship between the elements of the systems, and changing the goals or mindsets of the systems - each more powerful than the last. For example, mentoring and coaching enables individuals, and pro-bono work eases the challenge of getting professional credit. New modes of output, like plain language abstracts, change the relationship between publications and other outputs. We can work on changing mindsets by publicizing and celebrating individual successes. With more effort and impact, we can build collaborations in the collective impact model, where we bring scientific and community organizations together around a common agenda and shared measurement. Building on these examples, we will use this session to collect strategies and opportunities from all participants.

  16. Correction: Inferior alveolar nerve injury with laryngeal mask airway: a case report.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2011-11-30

    ABSTRACT: Following the publication of our article [Inferior alveolar nerve injury with laryngeal mask airway: a case report. Journal of Medical Case Reports 2011, 5:122] it was brought to our attention that we inadvertently used the registered trademark of the Laryngeal Mask Company Limited (LMA) as the abbreviation for laryngeal mask airway. A Portex(R) Soft Seal(R) Laryngeal Mask was used and not a device manufactured by the Laryngeal Mask Company.

  17. Quality of patient positioning during cerebral tomotherapy irradiation using different mask systems

    Energy Technology Data Exchange (ETDEWEB)

    Leitzen, C.; Wilhelm-Buchstab, T.; Garbe, S.; Luetter, C.; Muedder, T.; Simon, B.; Schild, H.H.; Schueller, H. [Universitaetsklinik Bonn, Radiologische Klinik, FE Strahlentherapie, Bonn (Germany)

    2014-04-15

    Patient immobilization during brain tumor radiotherapy is achieved by employing different mask systems. Two innovative mask systems were developed to minimize the problems of claustrophobic patients. Our aim was to evaluate whether the quality of patient immobilization using the new mask systems was equivalent to the standard mask system currently in use. Thirty-three patients with cerebral target volumes were irradiated using the Hi-Art II tomotherapy system between 2010 and 2012. Each group of 11 patients was fitted with one of the two new mask systems (Crystal {sup registered} or Open Face {sup registered} mask, Orfit) or the standard three-point mask (Raycast {sup registered} -HP, Orfit) and a total of 557 radiotherapy fractions were evaluated. After positioning was checked by MV-CT, the necessary table adjustments were noted. Data were analyzed by comparing the groups, and safety margins were calculated for nonimage-guided irradiation. The mean values of the table adjustments were: (a) lateral (mm): -0.22 (mask 1, standard deviation (σ): 2.15); 1.1 (mask 2, σ: 2.4); -0.64 (mask 3, σ: 2.9); (b) longitudinal (mm): -1 (mask 1, σ: 2.57); -0.5 (mask 2, σ: 4.7); -1.22 (mask 3, σ: 2.52); (c) vertical (mm): 0.62 (mask 1, σ: 0.63); 1.2 (mask 2, σ: 1.0); 0.57 (mask 3, σ: 0.28); (d) roll: 0.35 (mask 1, σ: 0.75); 0 (mask 2, σ: 0.8); 0.02 (mask 3, σ: 1.12). The outcomes suggest necessary safety margins of 5.49-7.38 mm (lateral), 5.4-6.56 mm (longitudinal), 0.82-3.9 mm (vertical), and 1.93-4.5 (roll). There were no significant differences between the groups. The new mask systems improve patient comfort while providing consistent patient positioning. (orig.)

  18. Quality of patient positioning during cerebral tomotherapy irradiation using different mask systems

    International Nuclear Information System (INIS)

    Leitzen, C.; Wilhelm-Buchstab, T.; Garbe, S.; Luetter, C.; Muedder, T.; Simon, B.; Schild, H.H.; Schueller, H.

    2014-01-01

    Patient immobilization during brain tumor radiotherapy is achieved by employing different mask systems. Two innovative mask systems were developed to minimize the problems of claustrophobic patients. Our aim was to evaluate whether the quality of patient immobilization using the new mask systems was equivalent to the standard mask system currently in use. Thirty-three patients with cerebral target volumes were irradiated using the Hi-Art II tomotherapy system between 2010 and 2012. Each group of 11 patients was fitted with one of the two new mask systems (Crystal registered or Open Face registered mask, Orfit) or the standard three-point mask (Raycast registered -HP, Orfit) and a total of 557 radiotherapy fractions were evaluated. After positioning was checked by MV-CT, the necessary table adjustments were noted. Data were analyzed by comparing the groups, and safety margins were calculated for nonimage-guided irradiation. The mean values of the table adjustments were: (a) lateral (mm): -0.22 (mask 1, standard deviation (σ): 2.15); 1.1 (mask 2, σ: 2.4); -0.64 (mask 3, σ: 2.9); (b) longitudinal (mm): -1 (mask 1, σ: 2.57); -0.5 (mask 2, σ: 4.7); -1.22 (mask 3, σ: 2.52); (c) vertical (mm): 0.62 (mask 1, σ: 0.63); 1.2 (mask 2, σ: 1.0); 0.57 (mask 3, σ: 0.28); (d) roll: 0.35 (mask 1, σ: 0.75); 0 (mask 2, σ: 0.8); 0.02 (mask 3, σ: 1.12). The outcomes suggest necessary safety margins of 5.49-7.38 mm (lateral), 5.4-6.56 mm (longitudinal), 0.82-3.9 mm (vertical), and 1.93-4.5 (roll). There were no significant differences between the groups. The new mask systems improve patient comfort while providing consistent patient positioning. (orig.)

  19. Measurements from preterm infants to guide face mask size.

    Science.gov (United States)

    O'Shea, Joyce E; Thio, Marta; Owen, Louise S; Wong, Connie; Dawson, Jennifer A; Davis, Peter G

    2016-07-01

    International guidelines recommend that an appropriately sized face mask for providing positive pressure ventilation should cover the mouth and nose but not the eyes and should not overlap the chin. This study aimed to measure the dimensions of preterm infants' faces and compare these with the size of the most commonly available face masks (external diameter 50 mm) and the smallest masks available (external diameters 35 and 42 mm). Infants 24-33 weeks' postmenstrual age (PMA) were photographed in a standardised manner. Images were analysed using ImageJ software (National Institute of Health, USA) to calculate the distance from the nasofrontal groove to the mental protuberance. This facial measurement corresponds to the external diameter of an optimally fitting mask. A cohort of 107 infants between 24 and 33 weeks' gestational age, including at least 10 infants per week of gestation, was photographed within 72 h after birth and weekly until 33 weeks' PMA. 347 photographs were analysed. Infants of 24, 26, 28, 30 and 32 weeks' PMA had mean (SD) facial measurements of 32 (2), 36 (3), 38 (4), 41 (2) and 43 (4) mm, respectively. There were no significant differences when examined by gender or when small for gestational age infants were excluded. The smallest size of some brands of mask is too large for many preterm infants. Masks of 35 mm diameter are suitable for infants Masks of 42 mm diameter are suitable for infants 27-33 weeks' PMA or 750-2500 g. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Comparison of the OxyMask and Venturi Mask in the Delivery of Supplemental Oxygen: Pilot Study in Oxygen-Dependent Patients

    Directory of Open Access Journals (Sweden)

    Jaime M Beecroft

    2006-01-01

    Full Text Available BACKGROUND: The OxyMask (Southmedic Inc, Canada is a new face mask for oxygen delivery that uses a small ‘diffuser’ to concentrate and direct oxygen toward the mouth and nose. The authors hypothesized that this unique design would enable the OxyMask to deliver oxygen more efficiently than a Venturi mask (Hudson RCI, USA in patients with chronic hypoxemia.

  1. Emergency face-mask removal effectiveness: a comparison of traditional and nontraditional football helmet face-mask attachment systems.

    Science.gov (United States)

    Swartz, Erik E; Belmore, Keith; Decoster, Laura C; Armstrong, Charles W

    2010-01-01

    Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Controlled laboratory study. Applied biomechanics laboratory. Twenty-five certified athletic trainers. The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F(4,20)  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F(4,20)  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F(4,20)  =  43.20, P  =  .001), with participants reporting average

  2. Emergency Face-Mask Removal Effectiveness: A Comparison of Traditional and Nontraditional Football Helmet Face-Mask Attachment Systems

    Science.gov (United States)

    Swartz, Erik E.; Belmore, Keith; Decoster, Laura C.; Armstrong, Charles W.

    2010-01-01

    Abstract Context: Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. Objective: To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Design: Controlled laboratory study. Setting: Applied biomechanics laboratory. Participants: Twenty-five certified athletic trainers. Intervention(s): The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Main Outcome Measure(s): Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Results: Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F4,20  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F4,20  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected

  3. Optical performances of the FM JEM-X masks

    Science.gov (United States)

    Reglero, V.; Rodrigo, J.; Velasco, T.; Gasent, J. L.; Chato, R.; Alamo, J.; Suso, J.; Blay, P.; Martínez, S.; Doñate, M.; Reina, M.; Sabau, D.; Ruiz-Urien, I.; Santos, I.; Zarauz, J.; Vázquez, J.

    2001-09-01

    The JEM-X Signal Multiplexing Systems are large HURA codes "written" in a pure tungsten plate 0.5 mm thick. 24.247 hexagonal pixels (25% open) are spread over a total area of 535 mm diameter. The tungsten plate is embedded in a mechanical structure formed by a Ti ring, a pretensioning system (Cu-Be) and an exoskeleton structure that provides the required stiffness. The JEM-X masks differ from the SPI and IBIS masks on the absence of a code support structure covering the mask assembly. Open pixels are fully transparent to X-rays. The scope of this paper is to report the optical performances of the FM JEM-X masks defined by uncertainties on the pixel location (centroid) and size coming from the manufacturing and assembly processes. Stability of the code elements under thermoelastic deformations is also discussed. As a general statement, JEM-X Mask optical properties are nearly one order of magnitude better than specified in 1994 during the ESA instrument selection.

  4. Cycle time reduction by Html report in mask checking flow

    Science.gov (United States)

    Chen, Jian-Cheng; Lu, Min-Ying; Fang, Xiang; Shen, Ming-Feng; Ma, Shou-Yuan; Yang, Chuen-Huei; Tsai, Joe; Lee, Rachel; Deng, Erwin; Lin, Ling-Chieh; Liao, Hung-Yueh; Tsai, Jenny; Bowhill, Amanda; Vu, Hien; Russell, Gordon

    2017-07-01

    The Mask Data Correctness Check (MDCC) is a reticle-level, multi-layer DRC-like check evolved from mask rule check (MRC). The MDCC uses extended job deck (EJB) to achieve mask composition and to perform a detailed check for positioning and integrity of each component of the reticle. Different design patterns on the mask will be mapped to different layers. Therefore, users may be able to review the whole reticle and check the interactions between different designs before the final mask pattern file is available. However, many types of MDCC check results, such as errors from overlapping patterns usually have very large and complex-shaped highlighted areas covering the boundary of the design. Users have to load the result OASIS file and overlap it to the original database that was assembled in MDCC process on a layout viewer, then search for the details of the check results. We introduce a quick result-reviewing method based on an html format report generated by Calibre® RVE. In the report generation process, we analyze and extract the essential part of result OASIS file to a result database (RDB) file by standard verification rule format (SVRF) commands. Calibre® RVE automatically loads the assembled reticle pattern and generates screen shots of these check results. All the processes are automatically triggered just after the MDCC process finishes. Users just have to open the html report to get the information they need: for example, check summary, captured images of results and their coordinates.

  5. Masked priming effect reflects evidence accumulated by the prime.

    Science.gov (United States)

    Kinoshita, Sachiko; Norris, Dennis

    2010-01-01

    In the same-different match task, masked priming is observed with the same responses but not different responses. Norris and Kinoshita's (2008) Bayesian reader account of masked priming explains this pattern based on the same principle as that explaining the absence of priming for nonwords in the lexical decision task. The pattern of priming follows from the way the model makes optimal decisions in the two tasks; priming does not depend on first activating the prime and then the target. An alternative explanation is in terms of a bias towards responding "same" that exactly counters the facilitatory effect of lexical access. The present study tested these two views by varying both the degree to which the prime predicts the response and the visibility of the prime. Unmasked primes produced effects expected from the view that priming is influenced by the degree to which the prime predicts the response. In contrast, with masked primes, the size of priming for the same response was completely unaffected by predictability. These results rule out response bias as an explanation of the absence of masked priming for different responses and, in turn, indicate that masked priming is not a consequence of automatic lexical access of the prime.

  6. Impact of thermoplastic mask on dosimetry of different radiotherapeutic beams

    International Nuclear Information System (INIS)

    Chen Lixin; Zhang Li; Qian Jianyang; Huang Xiaoyan; Lu Jie; Huang Shaomin

    2003-01-01

    Objective: To determine the influence of auxiliary thermoplastic mask on dose distribution of photon or electron beams. Methods: Using the PTW Marcus 23343 type fixed-separation parallel-plate ionization chamber in a special phantom(PMMA), the change of photon dose buildup region was measured with rectification of Bruce empirical formula. Using 3-D water phantom, the central axis percentage depth doses (PDD) of electron beams were measured with verification of the parallel-plate ionization chamber at several given depths. Results: When 8 MV X-ray was delivered through the added facial mask, the buildup region doses were increased obviously with a 25% relative increment beneath near the surface. When 8, 12, 15 MeV electron beams and mask were used, all PDD curves moved to the surface. Conclusions: The impact of thermoplastic mask on the dose increase in the X-ray buildup region, and on the PDD decrease in the electron beam target region should be paid much more attention. And the dose distribution, with an added mask, will have to be re-evaluated in 3-D conformal radiotherapy

  7. X ray reflection masks: Manufacturing, characterization and first tests

    Science.gov (United States)

    Rahn, Stephen

    1992-09-01

    SXPL (Soft X-ray Projection Lithography) multilayer mirrors are characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors with a 2d in the region of 14 nm were characterized by Cu-k(alpha) grazing incidence as well as soft X-ray normal incidence reflectivity measurements. The multilayer mirrors were patterned by reactive ion etching with CF4 using a photoresist as etch mask, thus producing X-ray reflection masks. The masks were tested at the synchrotron radiation laboratory of the electron accelerator ELSA. A double crystal X-ray monochromator was modified so as to allow about 0.5 sq cm of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto a resist and structure sizes down to 8 micrometers were nicely reproduced. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.

  8. Metal oxide multilayer hard mask system for 3D nanofabrication

    Science.gov (United States)

    Han, Zhongmei; Salmi, Emma; Vehkamäki, Marko; Leskelä, Markku; Ritala, Mikko

    2018-02-01

    We demonstrate the preparation and exploitation of multilayer metal oxide hard masks for lithography and 3D nanofabrication. Atomic layer deposition (ALD) and focused ion beam (FIB) technologies are applied for mask deposition and mask patterning, respectively. A combination of ALD and FIB was used and a patterning procedure was developed to avoid the ion beam defects commonly met when using FIB alone for microfabrication. ALD grown Al2O3/Ta2O5/Al2O3 thin film stacks were FIB milled with 30 keV gallium ions and chemically etched in 5% tetramethylammonium hydroxide at 50 °C. With metal evaporation, multilayers consisting of amorphous oxides Al2O3 and Ta2O5 can be tailored for use in 2D lift-off processing, in preparation of embedded sub-100 nm metal lines and for multilevel electrical contacts. Good pattern transfer was achieved by lift-off process from the 2D hard mask for micro- and nano-scaled fabrication. As a demonstration of the applicability of this method to 3D structures, self-supporting 3D Ta2O5 masks were made from a film stack on gold particles. Finally, thin film resistors were fabricated by utilizing controlled stiction of suspended Ta2O5 structures.

  9. Automatic pattern localization across layout database and photolithography mask

    Science.gov (United States)

    Morey, Philippe; Brault, Frederic; Beisser, Eric; Ache, Oliver; Röth, Klaus-Dieter

    2016-03-01

    Advanced process photolithography masks require more and more controls for registration versus design and critical dimension uniformity (CDU). The distribution of the measurement points should be distributed all over the whole mask and may be denser in areas critical to wafer overlay requirements. This means that some, if not many, of theses controls should be made inside the customer die and may use non-dedicated patterns. It is then mandatory to access the original layout database to select patterns for the metrology process. Finding hundreds of relevant patterns in a database containing billions of polygons may be possible, but in addition, it is mandatory to create the complete metrology job fast and reliable. Combining, on one hand, a software expertise in mask databases processing and, on the other hand, advanced skills in control and registration equipment, we have developed a Mask Dataprep Station able to select an appropriate number of measurement targets and their positions in a huge database and automatically create measurement jobs on the corresponding area on the mask for the registration metrology system. In addition, the required design clips are generated from the database in order to perform the rendering procedure on the metrology system. This new methodology has been validated on real production line for the most advanced process. This paper presents the main challenges that we have faced, as well as some results on the global performances.

  10. Objective measures of binaural masking level differences and comodulation masking release based on late auditory evoked potentials.

    Science.gov (United States)

    Epp, Bastian; Yasin, Ifat; Verhey, Jesko L

    2013-12-01

    The audibility of important sounds is often hampered due to the presence of other masking sounds. The present study investigates if a correlate of the audibility of a tone masked by noise is found in late auditory evoked potentials measured from human listeners. The audibility of the target sound at a fixed physical intensity is varied by introducing auditory cues of (i) interaural target signal phase disparity and (ii) coherent masker level fluctuations in different frequency regions. In agreement with previous studies, psychoacoustical experiments showed that both stimulus manipulations result in a masking release (i: binaural masking level difference; ii: comodulation masking release) compared to a condition where those cues are not present. Late auditory evoked potentials (N1, P2) were recorded for the stimuli at a constant masker level, but different signal levels within the same set of listeners who participated in the psychoacoustical experiment. The data indicate differences in N1 and P2 between stimuli with and without interaural phase disparities. However, differences for stimuli with and without coherent masker modulation were only found for P2, i.e., only P2 is sensitive to the increase in audibility, irrespective of the cue that caused the masking release. The amplitude of P2 is consistent with the psychoacoustical finding of an addition of the masking releases when both cues are present. Even though it cannot be concluded where along the auditory pathway the audibility is represented, the P2 component of auditory evoked potentials is a candidate for an objective measure of audibility in the human auditory system. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. A SYSTEMIC VISION OF BIOLOGY: OVERCOMING LINEARITY

    Directory of Open Access Journals (Sweden)

    M. Mayer

    2005-07-01

    were used to build  a hipermedia  material.  This  technology  permit  overcomes a linear  communication, improving the  comprehension  of the network perspective.   The teachers  speeches revealed  their  conceptual  con- structions along the  course,  showed the development of the  competences  in identify  interconnection points  in the flow and chemical cycling of energy, compatible  with a systemic view of life.

  12. Video encryption using chaotic masks in joint transform correlator

    Science.gov (United States)

    Saini, Nirmala; Sinha, Aloka

    2015-03-01

    A real-time optical video encryption technique using a chaotic map has been reported. In the proposed technique, each frame of video is encrypted using two different chaotic random phase masks in the joint transform correlator architecture. The different chaotic random phase masks can be obtained either by using different iteration levels or by using different seed values of the chaotic map. The use of different chaotic random phase masks makes the decryption process very complex for an unauthorized person. Optical, as well as digital, methods can be used for video encryption but the decryption is possible only digitally. To further enhance the security of the system, the key parameters of the chaotic map are encoded using RSA (Rivest-Shamir-Adleman) public key encryption. Numerical simulations are carried out to validate the proposed technique.

  13. Video encryption using chaotic masks in joint transform correlator

    International Nuclear Information System (INIS)

    Saini, Nirmala; Sinha, Aloka

    2015-01-01

    A real-time optical video encryption technique using a chaotic map has been reported. In the proposed technique, each frame of video is encrypted using two different chaotic random phase masks in the joint transform correlator architecture. The different chaotic random phase masks can be obtained either by using different iteration levels or by using different seed values of the chaotic map. The use of different chaotic random phase masks makes the decryption process very complex for an unauthorized person. Optical, as well as digital, methods can be used for video encryption but the decryption is possible only digitally. To further enhance the security of the system, the key parameters of the chaotic map are encoded using RSA (Rivest–Shamir–Adleman) public key encryption. Numerical simulations are carried out to validate the proposed technique. (paper)

  14. Masked depression: its interrelations with somatization, hypochondriasis and conversion.

    Science.gov (United States)

    Fisch, R Z

    1987-01-01

    Masked depression appears to be a common clinical phenomenon. Most depressions present with some somatic complaints in addition to affective and cognitive ones. About one half of all depressions seen by primary care physicians initially present predominantly or exclusively with somatic symptoms. Many of these depressions are not recognized or are misdiagnosed and mistreated. The possible reasons for this are discussed here. The phenomenon of somatization in depressions and other conditions is reviewed and the interface with other related clinical problems like hypochondriasis and conversion is delineated. It is hypothesized that the proportion of depressions that are masked is positively correlated to the patients' tendency to somatize and negatively correlated to the doctors' ability to recognize depressions that hide behind somatic complaints. Suggestions for the diagnosis and treatment of masked depressions are given.

  15. Emotional conditioning to masked stimuli and modulation of visuospatial attention.

    Science.gov (United States)

    Beaver, John D; Mogg, Karin; Bradley, Brendan P

    2005-03-01

    Two studies investigated the effects of conditioning to masked stimuli on visuospatial attention. During the conditioning phase, masked snakes and spiders were paired with a burst of white noise, or paired with an innocuous tone, in the conditioned stimulus (CS)+ and CS- conditions, respectively. Attentional allocation to the CSs was then assessed with a visual probe task, in which the CSs were presented unmasked (Experiment 1) or both unmasked and masked (Experiment 2), together with fear-irrelevant control stimuli (flowers and mushrooms). In Experiment 1, participants preferentially allocated attention to CS+ relative to control stimuli. Experiment 2 suggested that this attentional bias depended on the perceived aversiveness of the unconditioned stimulus and did not require conscious recognition of the CSs during both acquisition and expression. Copyright 2005 APA, all rights reserved.

  16. Complex Pupil Masks for Aberrated Imaging of Closely Spaced Objects

    Science.gov (United States)

    Reddy, A. N. K.; Sagar, D. K.; Khonina, S. N.

    2017-12-01

    Current approach demonstrates the suppression of optical side-lobes and the contraction of the main lobe in the composite image of two object points of the optical system under the influence of defocusing effect when an asymmetric phase edges are imposed over the apodized circular aperture. The resolution of two point sources having different intensity ratio is discussed in terms of the modified Sparrow criterion, functions of the degree of coherence of the illumination, the intensity difference and the degree of asymmetric phase masking. Here we have introduced and explored the effects of focus aberration (defect-of-focus) on the two-point resolution of the optical systems. Results on the aberrated composite image of closely spaced objects with amplitude mask and asymmetric phase masks forms a significant contribution in astronomical and microscopic observations.

  17. Influence of binary mask estimation errors on robust speaker identification

    DEFF Research Database (Denmark)

    May, Tobias

    2017-01-01

    Missing-data strategies have been developed to improve the noise-robustness of automatic speech recognition systems in adverse acoustic conditions. This is achieved by classifying time-frequency (T-F) units into reliable and unreliable components, as indicated by a so-called binary mask. Different...... approaches have been proposed to handle unreliable feature components, each with distinct advantages. The direct masking (DM) approach attenuates unreliable T-F units in the spectral domain, which allows the extraction of conventionally used mel-frequency cepstral coefficients (MFCCs). Instead of attenuating....... Since each of these approaches utilizes the knowledge about reliable and unreliable feature components in a different way, they will respond differently to estimation errors in the binary mask. The goal of this study was to identify the most effective strategy to exploit knowledge about reliable...

  18. Vitreous carbon mask substrate for X-ray lithography

    Science.gov (United States)

    Aigeldinger, Georg [Livermore, CA; Skala, Dawn M [Fremont, CA; Griffiths, Stewart K [Livermore, CA; Talin, Albert Alec [Livermore, CA; Losey, Matthew W [Livermore, CA; Yang, Chu-Yeu Peter [Dublin, CA

    2009-10-27

    The present invention is directed to the use of vitreous carbon as a substrate material for providing masks for X-ray lithography. The new substrate also enables a small thickness of the mask absorber used to pattern the resist, and this enables improved mask accuracy. An alternative embodiment comprised the use of vitreous carbon as a LIGA substrate wherein the VC wafer blank is etched in a reactive ion plasma after which an X-ray resist is bonded. This surface treatment provides a surface enabling good adhesion of the X-ray photoresist and subsequent nucleation and adhesion of the electrodeposited metal for LIGA mold-making while the VC substrate practically eliminates secondary radiation effects that lead to delamination of the X-ray resist form the substrate, the loss of isolated resist features, and the formation of a resist layer adjacent to the substrate that is insoluble in the developer.

  19. Clay facial masks: physicochemical stability at different storage temperatures.

    Science.gov (United States)

    Zague, Vivian; de Almeida Silva, Diego; Baby, André Rolim; Kaneko, Telma Mary; Velasco, Maria Valéria Robles

    2007-01-01

    Clay facial masks--formulations that contain a high percentage of solids dispersed in a liquid vehicle--have become of special interest due to specific properties presented by clays, such as particle size, cooling index, high adsorption capacity, and plasticity. Although most of the physicochemical properties of clay dispersions have been studied, specific aspects concerning the physicochemical stability of clay mask products remain unclear. This work aimed at investigating the accelerated physicochemical stability of clay mask formulations stored at different temperatures. Formulations were subjected to centrifuge testing and to thermal treatment for 15 days, during which temperature was varied from -5.0 degrees to 45.0 degrees C. The apparent viscosity and visual aspect (homogeneity) of all formulations were affected by temperature variation, whereas color, odor, and pH value remained unaltered. These results, besides the estimation of physicochemical stability under aging, can be useful in determining the best storage conditions for clay-based formulations.

  20. Radioprotective activity of shigella antigens

    International Nuclear Information System (INIS)

    Klemparskaya, N.N.; Gorbunova, E.S.; Dobronravova, N.N.

    1981-01-01

    The possibility of using experimental microbe antigenous preparation out of Flexner and Zonne shigellas as a protector and a remedy in the case of gamma irradiation, is investigated. The experiments are carried out on mice of both sexes immunized before or after irradiation by two methods: subcutaneously and enerally. It is found that in most cases investigated, the introduction of the experimental preparation 3, 5, 7 and 10 days before irradiation increases the survivability of animals [ru

  1. Development of movable mask system to cope with high beam current

    International Nuclear Information System (INIS)

    Suetsugu, Y.; Shibata, K.; Sanami, T.; Kageyama, T.; Takeuchi, Y.

    2003-01-01

    The KEK B factory (KEKB), a high current electron-positron collider, has a movable mask (or collimator) system to reduce the background noise in the BELLE detector coming from spent particles. The early movable masks, however, had severe problems of heating, arcing, and vacuum leaks over the stored beam current of several hundred mA. The cause is intense trapped higher order modes (HOMs) excited at the mask head, where the cross section of the beam chamber changed drastically. The mask head, made of copper-tungsten alloy or pure copper, was frequently damaged by hitting of the high energy beam at the same time. Since the problems of the mask were revealed, several kinds of improved masks have been designed employing rf technologies in dealing with the HOM and installed to the ring step by step. Much progress has come from adopting a trapped-mode free structure, where the mask was a bent chamber itself. Recently the further improved mask with a reduced HOM design or HOM dampers was developed to suppress the heating of vacuum components near the mask due to the HOM traveling from the mask. To avoid damage to the mask head, on the other hand, a titanium mask head was tried. The latest masks are working as expected now at the stored beam current of 1.5 A. Presented are the problems and experiences on the movable mask system for the KEKB, which are characteristic of and common in a high intensity accelerator

  2. Maximizing noise energy for noise-masking studies.

    Science.gov (United States)

    Jules Étienne, Cédric; Arleo, Angelo; Allard, Rémy

    2017-08-01

    Noise-masking experiments are widely used to investigate visual functions. To be useful, noise generally needs to be strong enough to noticeably impair performance, but under some conditions, noise does not impair performance even when its contrast approaches the maximal displayable limit of 100 %. To extend the usefulness of noise-masking paradigms over a wider range of conditions, the present study developed a noise with great masking strength. There are two typical ways of increasing masking strength without exceeding the limited contrast range: use binary noise instead of Gaussian noise or filter out frequencies that are not relevant to the task (i.e., which can be removed without affecting performance). The present study combined these two approaches to further increase masking strength. We show that binarizing the noise after the filtering process substantially increases the energy at frequencies within the pass-band of the filter given equated total contrast ranges. A validation experiment showed that similar performances were obtained using binarized-filtered noise and filtered noise (given equated noise energy at the frequencies within the pass-band) suggesting that the binarization operation, which substantially reduced the contrast range, had no significant impact on performance. We conclude that binarized-filtered noise (and more generally, truncated-filtered noise) can substantially increase the energy of the noise at frequencies within the pass-band. Thus, given a limited contrast range, binarized-filtered noise can display higher energy levels than Gaussian noise and thereby widen the range of conditions over which noise-masking paradigms can be useful.

  3. Etch bias inversion during EUV mask ARC etch

    Science.gov (United States)

    Lajn, Alexander; Rolff, Haiko; Wistrom, Richard

    2017-07-01

    The introduction of EUV lithography to high volume manufacturing is now within reach for 7nm technology node and beyond (1), at least for some steps. The scheduling is in transition from long to mid-term. Thus, all contributors need to focus their efforts on the production requirements. For the photo mask industry, these requirements include the control of defectivity, CD performance and lifetime of their masks. The mask CD performance including CD uniformity, CD targeting, and CD linearity/ resolution, is predominantly determined by the photo resist performance and by the litho and etch processes. State-of-the-art chemically amplified resists exhibit an asymmetric resolution for directly and indirectly written features, which usually results in a similarly asymmetric resolution performance on the mask. This resolution gap may reach as high as multiple tens of nanometers on the mask level in dependence of the chosen processes. Depending on the printing requirements of the wafer process, a reduction or even an increase of this gap may be required. A potential way of tuning via the etch process, is to control the lateral CD contribution during etch. Aside from process tuning knobs like pressure, RF powers and gases, which usually also affect CD linearity and CD uniformity, the simplest knob is the etch time itself. An increased over etch time results in an increased CD contribution in the normal case. , We found that the etch CD contribution of ARC layer etch on EUV photo masks is reduced by longer over etch times. Moreover, this effect can be demonstrated to be present for different etch chambers and photo resists.

  4. Low-defect reflective mask blanks for extreme ultraviolet lithography

    International Nuclear Information System (INIS)

    Burkhart, S C; Cerjarn, C; Kearney, P; Mirkarimi, P; Ray-Chaudhuri, A; Walton, C.

    1999-01-01

    Extreme Ultraviolet Lithgraphy (EUVL) is an emerging technology for fabrication of sub-100 nm feature sizes on silicon, following the SIA road map well into the 21st century. The specific EUVL system described is a scanned, projection lithography system with a 4:1 reduction, using a laser plasma EUV source. The mask and all of the system optics are reflective, multilayer mirrors which function in the extreme ultraviolet at 13.4 nm wavelength. Since the masks are imaged to the wafer exposure plane, mask defects greater than 80% of the exposure plane CD (for 4:1 reduction) will in many cases render the mask useless, whereas intervening optics can have defects which are not a printing problem. For the 100 nm node, we must reduce defects to less than 0.01/cm ampersand sup2; at sign 80nm or larger to obtain acceptable mask production yields. We have succeeded in reducing the defects to less than 0.1/cm ampersand sup2; for defects larger than 130 nm detected by visible light inspection tools, however our program goal is to achieve 0.01/cm ampersand sup2; in the near future. More importantly though, we plan to have a detailed understanding of defect origination and the effect on multilayer growth in order to mitigate defects below the 10 -2 /cm ampersand sup2; level on the next generation of mask blank deposition systems. In this paper we will discuss issues and results from the ion-beam multilayer deposition tool, details of the defect detection and characterization facility, and progress on defect printability modeling

  5. The contribution of forward masking to saccadic inhibition of return.

    Science.gov (United States)

    Souto, David; Born, Sabine; Kerzel, Dirk

    2018-03-08

    Inhibition of return is the name typically given to the prolonged latency of motor responses directed to a previously cued target location. There is intense debate about the origins of this effect and its function, but most take for granted (despite lack of evidence) that it depends little on forward masking. Therefore, we re-examined the role of forward masking in inhibition of return. Forward masking was indexed by slower saccadic reaction times (SRTs) when the target orientation repeated the cue orientation at the same location. We confirmed effects of orientation repetition in the absence of an attentional bias when cues were presented on both sides of fixation (bilateral presentation). The effect of orientation repetition was reduced with high target contrast, consistent with a low-level origin such as contrast gain control in early visual areas. When presenting cues on only one side of fixation (unilateral presentation), we obtained inhibition of return with longer cue-target intervals and facilitation with targets presented shortly after the cue. The effect of orientation repetition was reduced when facilitation was observed, but was as strong as with bilateral cues when inhibition of return was observed. Therefore, forward masking may contribute to the inhibition of return effect by delaying reaction times to repeated features at the same location, but is not a principal cause of inhibition of return; in agreement with previous views. The saccadic inhibition of return effect is a reaction-time cost when responding to a pre-cued location. Additional object updating costs are typically invoked to explain reaction-time costs observed when cue and target have the same shape. Yet, lower-level, forward masking of the target by the cue can not be ruled out. Importantly, we show an effect of orientation repetition that is consistent with low-level forward masking rather than object updating costs and that does not interact with inhibition of return.

  6. Serotonin dependent masking of hippocampal sharp wave ripples.

    Science.gov (United States)

    ul Haq, Rizwan; Anderson, Marlene L; Hollnagel, Jan-Oliver; Worschech, Franziska; Sherkheli, Muhammad Azahr; Behrens, Christoph J; Heinemann, Uwe

    2016-02-01

    Sharp wave ripples (SPW-Rs) are thought to play an important role in memory consolidation. By rapid replay of previously stored information during slow wave sleep and consummatory behavior, they result from the formation of neural ensembles during a learning period. Serotonin (5-HT), suggested to be able to modify SPW-Rs, can affect many neurons simultaneously by volume transmission and alter network functions in an orchestrated fashion. In acute slices from dorsal hippocampus, SPW-Rs can be induced by repeated high frequency stimulation that induces long-lasting LTP. We used this model to study SPW-R appearance and modulation by 5-HT. Although stimulation in presence of 5-HT permitted LTP induction, SPW-Rs were "masked"--but appeared after 5-HT wash-out. This SPW-R masking was dose dependent with 100 nM 5-HT being sufficient--if the 5-HT re-uptake inhibitor citalopram was present. Fenfluramine, a serotonin releaser, could also mask SPW-Rs. Masking was due to 5-HT1A and 5-HT2A/C receptor activation. Neither membrane potential nor membrane conductance changes in pyramidal cells caused SPW-R blockade since both remained unaffected by combining 5-HT and citalopram. Moreover, 10 and 30 μM 5-HT mediated SPW-R masking preceded neuronal hyperpolarization and involved reduced presynaptic transmitter release. 5-HT, as well as a 5-HT1A agonist, augmented paired pulse facilitation and affected the coefficient of variance. Spontaneous SPW-Rs in mice hippocampal slices were also masked by 5-HT and fenfluramine. While neuronal ensembles can acquire long lasting LTP during higher 5-HT levels, lower 5-HT levels enable neural ensembles to replay previously stored information and thereby permit memory consolidation memory. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Chlorphenesin: an antigen-associated immunosuppressant.

    Science.gov (United States)

    Whang, H Y; Neter, E

    1970-07-01

    Chlorphenesin (3-p-chlorophenoxy-1,2-propanediol), when injected intravenously together with either of two common bacterial antigens, inhibits the antibody response of the rabbit. The antigens studied are those common to Enterobacteriaceae and to gram-positive bacteria. The immunosuppression is contingent upon incubation of chlorphenesin and antigen in vitro prior to administration, since separate injection of antigen and inhibitor or of mixtures without prior incubation yields undiminished antibody response. Chlorphenesin, as shown by hemagglutination-inhibition tests, does not alter the antigenic determinants, because antibody neutralization occurs in the presence or absence of the drug. The immunosuppressive effect is reversible, since precipitation of chlorphenesin at 4 C substantially restores immunogenicity. Animals immunized with antigen-drug mixtures, which fail to respond with significant antibody production, nonetheless are immunologically primed. It is concluded that chlorphenesin represents another example of antigen-associated immunosuppressants.

  8. Presentation of lipid antigens to T cells.

    Science.gov (United States)

    Mori, Lucia; De Libero, Gennaro

    2008-04-15

    T cells specific for lipid antigens participate in regulation of the immune response during infections, tumor immunosurveillance, allergy and autoimmune diseases. T cells recognize lipid antigens as complexes formed with CD1 antigen-presenting molecules, thus resembling recognition of MHC-peptide complexes. The biophysical properties of lipids impose unique mechanisms for their delivery, internalization into antigen-presenting cells, membrane trafficking, processing, and loading of CD1 molecules. Each of these steps is controlled at molecular and celular levels and determines lipid immunogenicity. Lipid antigens may derive from microbes and from the cellular metabolism, thus allowing the immune system to survey a large repertoire of immunogenic molecules. Recognition of lipid antigens facilitates the detection of infectious agents and the initiation of responses involved in immunoregulation and autoimmunity. This review focuses on the presentation mechanisms and specific recognition of self and bacterial lipid antigens and discusses the important open issues.

  9. Environment-aware ideal binary mask estimation using monaural cues

    DEFF Research Database (Denmark)

    May, Tobias; Dau, Torsten

    2013-01-01

    We present a monaural approach to speech segregation that estimates the ideal binary mask (IBM) by combining amplitude modulation spectrogram (AMS) features, pitch-based features and speech presence probability (SPP) features derived from noise statistics. To maintain a high mask estimation...... accuracy in the presence of various background noises, the system employs environment-specific segregation models and automatically selects the appropriate model for a given input signal. Furthermore, instead of classifying each timefrequency (T-F) unit independently, the a posteriori probabilities...... of speech and noise presence are evaluated by considering adjacent TF units. The proposed system achieves high classification accuracy....

  10. Can monaural temporal masking explain the ongoing precedence effect?

    Science.gov (United States)

    Freyman, Richard L; Morse-Fortier, Charlotte; Griffin, Amanda M; Zurek, Patrick M

    2018-02-01

    The precedence effect for transient sounds has been proposed to be based primarily on monaural processes, manifested by asymmetric temporal masking. This study explored the potential for monaural explanations with longer ("ongoing") sounds exhibiting the precedence effect. Transient stimuli were single lead-lag noise burst pairs; ongoing stimuli were trains of 63 burst pairs. Unlike with transients, monaural masking data for ongoing sounds showed no advantage for the lead, and are inconsistent with asymmetric audibility as an explanation for ongoing precedence. This result, along with supplementary measurements of interaural time discrimination, suggests different explanations for transient and ongoing precedence.

  11. Power spectrum model of visual masking: simulations and empirical data.

    Science.gov (United States)

    Serrano-Pedraza, Ignacio; Sierra-Vázquez, Vicente; Derrington, Andrew M

    2013-06-01

    In the study of the spatial characteristics of the visual channels, the power spectrum model of visual masking is one of the most widely used. When the task is to detect a signal masked by visual noise, this classical model assumes that the signal and the noise are previously processed by a bank of linear channels and that the power of the signal at threshold is proportional to the power of the noise passing through the visual channel that mediates detection. The model also assumes that this visual channel will have the highest ratio of signal power to noise power at its output. According to this, there are masking conditions where the highest signal-to-noise ratio (SNR) occurs in a channel centered in a spatial frequency different from the spatial frequency of the signal (off-frequency looking). Under these conditions the channel mediating detection could vary with the type of noise used in the masking experiment and this could affect the estimation of the shape and the bandwidth of the visual channels. It is generally believed that notched noise, white noise and double bandpass noise prevent off-frequency looking, and high-pass, low-pass and bandpass noises can promote it independently of the channel's shape. In this study, by means of a procedure that finds the channel that maximizes the SNR at its output, we performed numerical simulations using the power spectrum model to study the characteristics of masking caused by six types of one-dimensional noise (white, high-pass, low-pass, bandpass, notched, and double bandpass) for two types of channel's shape (symmetric and asymmetric). Our simulations confirm that (1) high-pass, low-pass, and bandpass noises do not prevent the off-frequency looking, (2) white noise satisfactorily prevents the off-frequency looking independently of the shape and bandwidth of the visual channel, and interestingly we proved for the first time that (3) notched and double bandpass noises prevent off-frequency looking only when the noise

  12. Masking Responses to Light in Period Mutant Mice

    Science.gov (United States)

    Pendergast, Julie S.; Yamazaki, Shin

    2013-01-01

    Masking is an acute effect of an external signal on an overt rhythm and is distinct from the process of entrainment. In the current study, we investigated the phase dependence and molecular mechanisms regulating masking effects of light pulses on spontaneous locomotor activity in mice. The circadian genes, Period1 (Per1) and Per2, are necessary components of the timekeeping machinery and entrainment by light appears to involve the induction of the expression of Per1 and Per2 mRNAs in the suprachiasmatic nuclei (SCN). We assessed the roles of the Per genes in regulating masking by assessing the effects of light pulses on nocturnal locomotor activity in C57BL/6J Per mutant mice. We found that Per1−/− and Per2−/− mice had robust negative masking responses to light. In addition, the locomotor activity of Per1−/−/Per2−/− mice appeared to be rhythmic in the light-dark (LD) cycle, and the phase of activity onset was advanced (but varied among individual mice) relative to lights off. This rhythm persisted for 1 to 2 days in constant darkness in some Per1−/−/Per2−/− mice. Furthermore, Per1−/−/Per2−/− mice exhibited robust negative masking responses to light. Negative masking was phase dependent in wild-type mice such that maximal suppression was induced by light pulses at zeitgeber time 14 (ZT14) and gradually weaker suppression occurred during light pulses at ZT16 and ZT18. By measuring the phase shifts induced by the masking protocol (light pulses were administered to mice maintained in the LD cycle), we found that the phase responsiveness of Per mutant mice was altered compared to wild-types. Together, our data suggest that negative masking responses to light are robust in Per mutant mice and that the Per1−/−/Per2−/− SCN may be a light-driven, weak/damping oscillator. PMID:21793695

  13. Ferromagnetic shadow mask for spray coating of polymer patterns

    DEFF Research Database (Denmark)

    Keller, Stephan Sylvest; Bosco, Filippo; Boisen, Anja

    2013-01-01

    We present the fabrication of a wafer-scale shadow mask with arrays of circular holes with diameters of 150–400 μm. Standard UV photolithography is used to define 700 μm thick SU-8 structures followed by electroplating of nickel and etching of the template. The ferromagnetic properties of the sha......We present the fabrication of a wafer-scale shadow mask with arrays of circular holes with diameters of 150–400 μm. Standard UV photolithography is used to define 700 μm thick SU-8 structures followed by electroplating of nickel and etching of the template. The ferromagnetic properties...

  14. Accurate masking technology for high-resolution powder blasting

    Science.gov (United States)

    Pawlowski, Anne-Gabrielle; Sayah, Abdeljalil; Gijs, Martin A. M.

    2005-07-01

    We have combined eroding 10 µm diameter Al2O3 particles with a new masking technology to realize the smallest and most accurate possible structures by powder blasting. Our masking technology is based on the sequential combination of two polymers:(i) the brittle epoxy resin SU8 for its photosensitivity and (ii) the elastic and thermocurable poly-dimethylsiloxane for its large erosion resistance. We have micropatterned various types of structures with a minimum width of 20 µm for test structures with an aspect ratio of 1, and 50 µm for test structures with an aspect ratio of 2.

  15. Spectrographic mask for digital registration of bright source spectra

    Directory of Open Access Journals (Sweden)

    Ademir Xavier

    2017-08-01

    Full Text Available In this work we present schematic diagrams for the construction of a spectrographic mask attachable to a camera objective in order to capture spectra using simple CD or DVD gratings. The mask is made of two parts: an adapter ring and elbow-shaped blockage for suitable registration of spectra in the lab and outdoors. By using a free software, we analyze and discuss the calibration of the wavelength scale of the solar spectrum, which allows us to identify many chemical elements in it. In the conclusion, we further discuss some interesting projects to be carried out by students using the idea.

  16. Extension of optical lithography by mask-litho integration with computational lithography

    Science.gov (United States)

    Takigawa, T.; Gronlund, K.; Wiley, J.

    2010-05-01

    Wafer lithography process windows can be enlarged by using source mask co-optimization (SMO). Recently, SMO including freeform wafer scanner illumination sources has been developed. Freeform sources are generated by a programmable illumination system using a micro-mirror array or by custom Diffractive Optical Elements (DOE). The combination of freeform sources and complex masks generated by SMO show increased wafer lithography process window and reduced MEEF. Full-chip mask optimization using source optimized by SMO can generate complex masks with small variable feature size sub-resolution assist features (SRAF). These complex masks create challenges for accurate mask pattern writing and low false-defect inspection. The accuracy of the small variable-sized mask SRAF patterns is degraded by short range mask process proximity effects. To address the accuracy needed for these complex masks, we developed a highly accurate mask process correction (MPC) capability. It is also difficult to achieve low false-defect inspections of complex masks with conventional mask defect inspection systems. A printability check system, Mask Lithography Manufacturability Check (M-LMC), is developed and integrated with 199-nm high NA inspection system, NPI. M-LMC successfully identifies printable defects from all of the masses of raw defect images collected during the inspection of a complex mask. Long range mask CD uniformity errors are compensated by scanner dose control. A mask CD uniformity error map obtained by mask metrology system is used as input data to the scanner. Using this method, wafer CD uniformity is improved. As reviewed above, mask-litho integration technology with computational lithography is becoming increasingly important.

  17. Pressure Ulcer Incidence in Patients Wearing Nasal-Oral Versus Full-Face Noninvasive Ventilation Masks.

    Science.gov (United States)

    Schallom, Marilyn; Cracchiolo, Lisa; Falker, Antoinette; Foster, Jennifer; Hager, JoAnn; Morehouse, Tamara; Watts, Peggy; Weems, Linda; Kollef, Marin

    2015-07-01

    Device-related pressure ulcers from noninvasive ventilation masks alter skin integrity and cause patients discomfort. To examine the incidence, location, and stage of pressure ulcers and patients' comfort with a nasal-oral mask compared with a full-face mask. A before-after study of a convenience sample of patients with noninvasive ventilation orders in 5 intensive care units was conducted. Two groups of 100 patients each received either the nasal-oral mask or the full-face mask. Skin was assessed before the mask was applied and every 12 hours after that or upon mask removal. Comfort levels were assessed every 12 hours on a Likert scale of 1 to 5 (1, most comfortable). A pressure ulcer developed in 20% of patients in the nasal-oral mask group and 2% of patients in the full-face mask group (P face mask (mean [SD], 1.9 [1.1]) than with the nasal-oral mask (mean [SD], 2.7 [1.2], P face mask and 25 (SD, 20.7) and 92% for nasal-oral mask. No patients who had a pressure ulcer develop with the nasal-oral mask had a pressure ulcer develop with the full-face mask. The full-face mask resulted in significantly fewer pressure ulcers and was more comfortable for patients. The full-face mask is a reasonable alternative to traditional nasal-oral masks for patients receiving noninvasive ventilation. ©2015 American Association of Critical-Care Nurses.

  18. MEDEA+ project 2T302 MUSCLE: masks through user's supply chain: leadership by excellence

    Science.gov (United States)

    Torsy, Andreas

    2008-04-01

    The rapid evolution of our information society depends on the continuous developments and innovations of semiconductor products. The cost per chip functionality keeps reducing by a factor of 2 every 18 month. However, this performance and success of the semiconductor industry critically depends on the quality of the lithographic photomasks. The need for the high quality of photomask drives lithography costs sensitively, which is a key factor in the manufacture of microelectronics devices. Therefore, the aim is to reduce production costs while overcoming challenges in terms of feature sizes, complexity and cycle times. Consequently, lithography processes must provide highest possible quality at reasonable prices. This way, the leadership in the lithographic area can be maintained and European chipmakers can stay competitive with manufacturers in the Far East and the USA. Under the umbrella of MEDEA+, a project called MUSCLE (>) has been started among leading semiconductor companies in Europe: ALTIS Semiconductor (Project Leader), ALCATEL Vacuum, ATMEL, CEA/LETI, Entegris, NXP Semiconductors, TOPPAN Photomasks, AMTC, Carl ZEISS SMS, DMS, Infineon Technologies, VISTEC Semiconductor, NIKON Precision, SCHOTT Lithotec, ASML, PHOTRONICS, IMEC, DCE, DNP Photomask, STMicroelectronics, XYALIS and iCADA. MUSCLE focuses particularly on mask data flow, photomask carrier, photomask defect characterization and photomask data handling. In this paper, we will discuss potential solutions like standardization and automation of the photomask data flow based on SEMI P10, the performance and the impact of the supply chain parameter within the photomask process, the standardization of photomask defect characterization and a discussion of the impact of new Reticle Enhancement Technologies (RET) such as mask process correction and finally a generic model to describe the photomasks key performance indicators for prototype photomasks.

  19. Why Mondragon? Analyzing What Works in Overcoming Inequalities

    Science.gov (United States)

    Redondo, Gisela; Santa Cruz, Ignacio; Rotger, Josep Maria

    2011-01-01

    Research using the critical communicative methodology (CCM) aims to identify the elements that help overcome inequalities. Drawing on research on the Basque Mondragon Corporation (MC), the authors focus on two major elements such as, selecting research cases that have been shown to succeed in overcoming inequalities, and communicative data…

  20. Fear of Public Speaking: How Can I Overcome It?

    Science.gov (United States)

    ... I overcome it? How can I overcome my fear of public speaking? Answers from Craig N. Sawchuk, Ph.D., L.P. Fear of public speaking is a common form of ... It can range from slight nervousness to paralyzing fear and panic. Many people with this fear avoid ...

  1. Comparison of Ventilation With One-Handed Mask Seal With an Intraoral Mask Versus Conventional Cuffed Face Mask in a Cadaver Model: A Randomized Crossover Trial.

    Science.gov (United States)

    Amack, Andrew J; Barber, Gary A; Ng, Patrick C; Smith, Thomas B; April, Michael D

    2017-01-01

    We compare received minute volume with an intraoral mask versus conventional cuffed face mask among medics obtaining a 1-handed mask seal on a cadaver model. This study comprised a randomized crossover trial of adult US Army combat medic volunteers participating in a cadaver laboratory as part of their training. We randomized participants to obtain a 1-handed mask seal during ventilation of a fresh unembalmed cadaver, first using either an intraoral airway device or conventional cuffed face mask. Participants obtained a 1-handed mask seal while a ventilator delivered 10 standardized 750-mL breaths during 1 minute. After a 5-minute rest period, they repeated the study with the alternative mask. The primary outcome measure was received minute volume as measured by a respirometer. Of 27 recruited participants, all completed the study. Median received minute volume was higher with the intraoral mask compared with conventional cuffed mask by 1.7 L (95% confidence interval 1.0 to 1.9 L; Pcadaver model. The intraoral mask may prove a useful airway adjunct for ventilation. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  2. The time-course of visual masking effects on saccadic responses indicates that masking interferes with reentrant processing

    DEFF Research Database (Denmark)

    Crouzet, S.; Pin, Simon Hviid Del; Overgaard, Morten

    2013-01-01

    Object substitution masking (OSM) occurs when a briefly presented target in a search array is surrounded by small dots that remain visible after the target disappears. Here, we tested the widespread assumption that OSM selectively impairs reentrant processing. If OSM interferes selectively...... with reentrant processing, then the first feedforward sweep should be left relatively intact. Using a standard OSM paradigm in combination with a saccadic choice task, giving access to an early phase of visual processing (the fastest saccades occurring only 100 ms after target onset), we compared the masking....... Interestingly, the same result was observed using backward masking. In a follow-up experiment, where we assessed observer’s visual awareness using single-trial visibility ratings, we demonstrated that these ultra-fast responses were actually linked to subsequent reported visibility. Taken together...

  3. A 3D-RBS study of irradiation-induced deformation and masking properties of ordered colloidal nanoparticulate masks

    International Nuclear Information System (INIS)

    Zolnai, Z.; Deak, A.; Nagy, N.; Toth, A.L.; Kotai, E.; Battistig, G.

    2010-01-01

    The 500 keV Xe 2+ irradiation-induced anisotropic deformation of ordered colloidal silica nanoparticulate masks is followed using 2 MeV 4 He + Rutherford Backscattering Spectrometry (RBS) with different measurement geometries and the improved data analysis capabilities of the RBS-MAST spectrum simulation code. The three-dimensional (3D) geometrical transformation from spherical to oblate ellipsoidal and polygonal shape and the decrease of the mask's hole size is described. The masking properties of the silica monolayer and the depth distribution of Xe in the underlying Si substrate vs. the irradiated Xe 2+ fluence are discussed. Field Emission Scanning Electron Microscopy (FESEM) is applied as complementary characterization tool. Our results give contribution to clarify the impact of ion-nanoparticle interactions on the potentials and limits of nanosphere lithography. We also show the capability of the conventional RBS technique to characterize laterally ordered submicron-sized three-dimensional structures.

  4. Actinic Mask Inspection at the ALS Initial Design Review

    International Nuclear Information System (INIS)

    Barty, A; Chapman, H; Sweeney, D; Levesque, R; Bokor, J; Gullikson, E; Jong, S; Liu, Y; Yi, M; Denbeaux, G; Goldberg, K; Naulleau, P; Denham, P; Rekawa, S; Baston, P; Tackaberry, R; Barale, P

    2003-01-01

    This report is the first milestone report for the actinic mask blank inspection project conducted at the VNL, which forms sub-section 3 of the Q1 2003 mask blank technology transfer program at the VNL. Specifically this report addresses deliverable 3.1.1--design review and preliminary tool design. The goal of this project is to design an actinic mask inspection tool capable of operating in two modes: high-speed scanning for the detection of multilayer defects (inspection mode), and a high-resolution aerial image mode in which the image emulates the imaging illumination conditions of a stepper system (aerial image or AIM mode). The purpose and objective of these two modes is as follows: (1) Defect inspection mode--This imaging mode is designed to scan large areas of the mask for defects EUV multilayer coatings. The goal is to detect the presence of multilayer defects on a mask blank and to store the co-ordinates for subsequent review in AIM mode, thus it is not essential that the illumination and imaging conditions match that of a production stepper. Potential uses for this imaging mode include: (a) Correlating the results obtained using actinic inspection with results obtained using other non-EUV defect inspection systems to verify that the non-EUV scanning systems are detecting all critical defects; (b) Gaining sufficient information to associate defects with particular processes, such as various stages of the multilayer deposition or different modes of operation of the deposition tool; and (c) Assessing the density and EUV impact of surface and multilayer anomalies. Because of the low defect density achieved using current multilayer coating technology it is necessary to be able to efficiently scan large areas of the mask in order to obtain sufficient statistics for use in cross-correlation experiments. Speed of operation as well as sensitivity is therefore key to operation in defect inspection mode. (2) Aerial Image Microscope (AIM) mode--In AIM mode the tool is

  5. Definition of purified enzyme-linked immunosorbent assay antigens from the culture filtrate protein of Mycobacterium bovis by proteomic analysis.

    Science.gov (United States)

    Cho, Yun Sang; Lee, Sang-Eun; Ko, Young Joon; Cho, Donghee; Lee, Hyang Shim; Hwang, Inyeong; Nam, Hyangmi; Heo, Eunjung; Kim, Jong Man; Jung, Sukchan

    2009-01-01

    Enzyme-linked immunosorbent assay (ELISA) has been developed as the ancillary diagnosis of bovine tuberculosis at ante-mortem to overcome the disadvantages of intradermal skin test. In this study, the antigenic proteins were purified, applied to bTB ELISA, and identified through proteomic analysis. Culture filtrate protein of Mycobacterium bovis was fractionated by MonoQ column chromatography, and examined the antigenicity by immunoblotting. The antigenic 20 kDa protein was in-gel digested and identified the antigenome by LTQ mass spectrometer and peptide match fingerprinting, which were MPB64, MPB70, MPB83, Fas, Smc, Nrp, RpoC, Transposase, LeuA, and MtbE. The 20 kDa protein exhibited the highest antigenicity to bTB positive cattle in ELISA and would be useful for bTB serological diagnosis.

  6. A conceptual approach to the masking effect of measures of disproportionality.

    Science.gov (United States)

    Maignen, Francois; Hauben, Manfred; Hung, Eric; Holle, Lionel Van; Dogne, Jean-Michel

    2014-02-01

    Masking is a statistical issue by which true signals of disproportionate reporting are hidden by the presence of other products in the database. Masking is currently not perfectly understood. There is no algorithm to identify the potential masking drugs to remove them for subsequent analyses of disproportionality. The primary objective of our study is to develop a mathematical framework for assessing the extent and impact of the masking effect of measures of disproportionality. We have developed a masking ratio that quantifies the masking effect of a given product. We have conducted a simulation study to validate our algorithm. The masking ratio is a measure of the strength of the masking effect whether the analysis is performed at the report or event level, and the manner in which reports are allocated to cells in the contingency table significantly impact the masking mechanisms. The reports containing both the product of interest and the masking product need to be handled appropriately. The proposed algorithm can use simplified masking provided that underlying assumptions (in particular the size of the database) are verified. For any event, the strongest masking effect is associated with the drug with the highest number of records (reports excluding the product of interest). Our study provides significant insights with practical implications for real-world pharmacovigilance that are supported by both real and simulated data. The public health impact of masking is still unknown. Copyright © 2013 John Wiley & Sons, Ltd.

  7. High reading skills mask dyslexia in gifted children

    NARCIS (Netherlands)

    van Viersen, Sietske; Kroesbergen, Evelyn|info:eu-repo/dai/nl/241607949; Slot, Esther|info:eu-repo/dai/nl/413578526; de Bree, Elise|info:eu-repo/dai/nl/292748868

    2016-01-01

    This study investigated how gifted children with dyslexia might be able to mask literacy problems and the role of possible compensatory mechanisms. The sample consisted of 121 Dutch primary school children that were divided over four groups (typically developing [TD] children, children with

  8. Mask of Black God: The Pleiades in Navajo Cosmology

    Science.gov (United States)

    Schulz, Teresa M.

    2005-01-01

    One Navajo legend attributes the creation of the primary stars and constellations to Black God. Today, a famous star cluster--the Pleiades--often appears on the traditional mask worn by chanters impersonating Black God during special ceremonies. In this case study, students learn about the Pleiades in Navajo cosmology while honing their…

  9. The Laryngeal Mask Airway (LMA) as an alternative to airway ...

    African Journals Online (AJOL)

    Background: To evaluate the possibility of airway management using a laryngeal mask airway (LMA) during dental procedures on mentally retarded (MR) patients and patients with genetic diseases. Design: A prospective pilot study. Setting: University Hospital. Methods: A pilot study was designed to induce general ...

  10. The Laryngeal Mask Airway Supreme™: safety and efficacy during ...

    African Journals Online (AJOL)

    Background: Laryngeal Mask Airway Supreme™ (LMA Supreme™) is a new single-use polyvinyl chloride supraglottic device that offers gastric access. To date, studies that have tested the LMA Supreme™) for use in laparoscopic surgery have been reported. We present the largest evaluative study that describes the use of ...

  11. Basilar-membrane modularity and the growth of forward masking

    NARCIS (Netherlands)

    Plack, C.J.; Oxenham, A.J.

    1998-01-01

    Forward masking growth functions were measured for pure-tone maskers and signals at 2 and 6 kHz as a function of the silent interval between the masker and signal. The inclusion of conditions involving short signals and short masker-signal intervals ensured that a wide range of signal thresholds

  12. 3-color photometry of a sunspot using speckle masking techniques

    NARCIS (Netherlands)

    Wiehr, E.; Sütterlin, P.

    1998-01-01

    A three-colour photometry is used to deduce the temperature of sunspot fine-structures. Using the Speckle-Masking method for image restoration, the resulting images (one per colour and burst) have a spatial resolution only limited by the telescope's aperture, i.e. 95km (blue), 145 km (red) and

  13. How important is lateral masking in visual search?

    NARCIS (Netherlands)

    Wertheim, AH; Hooge, ITC; Krikke, K; Johnson, A

    Five experiments are presented, providing empirical support of the hypothesis that the sensory phenomenon of lateral masking may explain many well-known visual search phenomena that are commonly assumed to be governed by cognitive attentional mechanisms. Experiment I showed that when the same visual

  14. Clustering Binary Data in the Presence of Masking Variables

    Science.gov (United States)

    Brusco, Michael J.

    2004-01-01

    A number of important applications require the clustering of binary data sets. Traditional nonhierarchical cluster analysis techniques, such as the popular K-means algorithm, can often be successfully applied to these data sets. However, the presence of masking variables in a data set can impede the ability of the K-means algorithm to recover the…

  15. Benchmarking EUV mask inspection beyond 0.25 NA

    International Nuclear Information System (INIS)

    Goldberg, Kenneth A.; Mochi, Iacopo; Anderson, Erik H.; Rekawa, Seno B.; Kemp, Charles D.; Huh, S.; Han, H.-S.; Naulleau, P.; Gunion, R.F.

    2008-01-01

    The SEMATECH Berkeley Actinic Inspection Tool (AIT) is an EUV-wavelength mask inspection microscope designed for direct aerial image measurements, and pre-commercial EUV mask research. Operating on a synchrotron bending magnet beamline, the AIT uses an off-axis Fresnel zoneplate lens to project a high-magnification EUV image directly onto a CCD camera. We present the results of recent system upgrades that have improved the imaging resolution, illumination uniformity, and partial coherence. Benchmarking tests show image contrast above 75% for 100-nm mask features, and significant improvements and across the full range of measured sizes. The zoneplate lens has been replaced by an array of user-selectable zoneplates with higher magnification and NA values up to 0.0875, emulating the spatial resolution of a 0.35-NA 4 x EUV stepper. Illumination uniformity is above 90% for mask areas 2-(micro)m-wide and smaller. An angle-scanning mirror reduces the high coherence of the synchrotron beamline light source giving measured σ values of approximately 0.125 at 0.0875 NA

  16. The masking breakdown point of multivariate outlier identification rules

    OpenAIRE

    Becker, Claudia; Gather, Ursula

    1997-01-01

    In this paper, we consider one-step outlier identifiation rules for multivariate data, generalizing the concept of so-called alpha outlier identifiers, as presented in Davies and Gather (1993) for the case of univariate samples. We investigate, how the finite-sample breakdown points of estimators used in these identification rules influence the masking behaviour of the rules.

  17. A coded mask telescope for the Spacelab 2 mission

    International Nuclear Information System (INIS)

    Willmore, A.P.; Skinner, G.K.; Eyles, C.J.; Ramsey, B.

    1984-01-01

    A dual coded mask telescope for the Spacelab 2 mission is now in the final stages of preparation at Birmingham University. It is due for launch in late 1984/early 1985 and will be by far the largest and most sophisticated such instrument to be flown in this time-frame. The design and capabilities of the telescope will be described. (orig.)

  18. "Kuldne mask" - hea vene teater Eestis / Laur Kaunissaare

    Index Scriptorium Estoniae

    Kaunissaare, Laur, 1982-

    2009-01-01

    6.-13. okt. Tallinnas ja Jõhvis toimuvast Venemaa rahvuslikust teatrifestivalist "Kuldne mask Eestis". Festivali lavastustest - Temur Tšheidze "Onukese unenägu", Declan Donnellan "Kaheteistkümnes öö", Lev Erenburgi "Äike" ja Alvis Hermanise "Šukšini jutustused"

  19. Vector wave diffraction pattern of slits masked by polarizing devices

    Indian Academy of Sciences (India)

    This calls for a systematic study of diffraction properties of different apertures using polarization-sensitive devices. In the present paper, we have studied the Fraunhofer diffraction pattern of slits masked by different kinds of polarizing devices which introduce a phase difference between the two orthogonal components of the ...

  20. Abstract This paper provides an introduction to the general mask ...

    African Journals Online (AJOL)

    Tracie1

    institution. ittle has been done on its ritualistic and religious inclinations; worse still, researches on its poetic compositions have been scanty. As an aspect of oral tradition, the mask tradition has within its fold, parts and branches that have very rich store houses of proverbial literature, unique poetry and idiomatic expressions.

  1. Modeling comodulation masking release using an equalization cancellation mechanism

    DEFF Research Database (Denmark)

    Piechowiak, Tobias; Ewert, Stephan; Dau, Torsten

    of the study investigates the relation between CMR and envelope-based binaural masking level differences (BMLD), using narrowband noise maskers and classical across-channel configurations (like N0Spi, N0Sm). In the second part, a model is presented that explicitly simulates CMR whereby the EC mechanism...

  2. The role of executive attention in object substitution masking.

    Science.gov (United States)

    Filmer, Hannah L; Wells-Peris, Roxanne; Dux, Paul E

    2017-05-01

    It was long thought that a key characteristic of object substitution masking (OSM) was the requirement for spatial attention to be dispersed for the mask to impact visual sensitivity. However, recent studies have provided evidence questioning whether spatial attention interacts with OSM magnitude, suggesting that the previous reports reflect the impact of performance being at ceiling for the low attention load conditions. Another technique that has been employed to modulate attention in OSM paradigms involves presenting the target stimulus foveally, but with another demanding task shown immediately prior, and thus taxing executive/temporal attention. Under such conditions, when the two tasks occur in close temporal proximity relatively to greater temporal separation, masking is increased. However this effect could also be influenced by performance being at ceiling in some conditions. Here, we manipulated executive attention for a foveated target using a dual-task paradigm. Critically, ceiling performance was avoided by thresholding the target stimulus prior to it being presented under OSM conditions. We found no evidence for an interaction between executive attention load and masking. Collectively, along with the previous findings, our results provide compelling evidence that OSM as a phenomenon occurs independently of attention.

  3. High Reading Skills Mask Dyslexia in Gifted Children

    Science.gov (United States)

    van Viersen, Sietske; Kroesbergen, Evelyn H.; Slot, Esther M.; de Bree, Elise H.

    2016-01-01

    This study investigated how gifted children with dyslexia might be able to mask literacy problems and the role of possible compensatory mechanisms. The sample consisted of 121 Dutch primary school children that were divided over four groups (typically developing [TD] children, children with dyslexia, gifted children, gifted children with…

  4. Constructing optimized binary masks for reservoir computing with delay systems

    Science.gov (United States)

    Appeltant, Lennert; van der Sande, Guy; Danckaert, Jan; Fischer, Ingo

    2014-01-01

    Reservoir computing is a novel bio-inspired computing method, capable of solving complex tasks in a computationally efficient way. It has recently been successfully implemented using delayed feedback systems, allowing to reduce the hardware complexity of brain-inspired computers drastically. In this approach, the pre-processing procedure relies on the definition of a temporal mask which serves as a scaled time-mutiplexing of the input. Originally, random masks had been chosen, motivated by the random connectivity in reservoirs. This random generation can sometimes fail. Moreover, for hardware implementations random generation is not ideal due to its complexity and the requirement for trial and error. We outline a procedure to reliably construct an optimal mask pattern in terms of multipurpose performance, derived from the concept of maximum length sequences. Not only does this ensure the creation of the shortest possible mask that leads to maximum variability in the reservoir states for the given reservoir, it also allows for an interpretation of the statistical significance of the provided training samples for the task at hand.

  5. Case report: Awake insertion of the intubating laryngeal mask ...

    African Journals Online (AJOL)

    Case report: Awake insertion of the intubating laryngeal mask airway using dexmedetomidine sedation. P Dhar, TR Tedore. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.1080/22201173.2003.10872999.

  6. Multiaperture spectroscopy with rapid mask fabrication and installation

    International Nuclear Information System (INIS)

    Fort, B.; Mellier, Y.; Picat, J.P.; Lelievre, G.; Rio, Y.

    1986-03-01

    A multiaperture spectroscopy device has been installed on the focal reducer at the Cassegrain focus of the Canada-France-Hawaii Telescope. The mask processing and positioning operations are described. Emphasis is placed on the speed and reliability of a fully automatic method controlled by a computer routine. Spectra obtained during the first observations at C.F.H.T. are shown as illustration

  7. Generalization of Supervised Learning for Binary Mask Estimation

    DEFF Research Database (Denmark)

    May, Tobias; Gerkmann, Timo

    2014-01-01

    This paper addresses the problem of speech segregation by es- timating the ideal binary mask (IBM) from noisy speech. Two methods will be compared, one supervised learning approach that incorporates a priori knowledge about the feature distri- bution observed during training. The second method...

  8. Prognostic importance of white coat and masked hypertention

    DEFF Research Database (Denmark)

    Gustavsen, Pia; Hansen, Tine

    2009-01-01

    The growing use of ambulatory blood pressure monitoring has led to an increased awareness of the two types of discrepancy between office blood pressure and ambulatory blood pressure, called white coat hypertension (WCH) and masked hypertension (MH). Based on several longitudinal studies, WCH...

  9. External Mask Based Depth and Light Field Camera

    Science.gov (United States)

    2013-12-08

    External mask based depth and light field camera Dikpal Reddy NVIDIA Research Santa Clara, CA dikpalr@nvidia.com Jiamin Bai University of California...passive depth acquisition technology is illustrated by the emergence of light field camera companies like Lytro [1], Raytrix [2] and Pelican Imaging

  10. The intubating laryngeal mask produces less heart rate response to ...

    African Journals Online (AJOL)

    Pc

    We compared heart rate and blood pressure changes to intubation produced by conventional laryngoscopic-guided intubation to those produced by blind intubation through the intubating laryngeal mask (ILM) in normotensive adults with normal airways. Forty paralysed, anaesthetised adults undergoing elective surgery ...

  11. Mask characterization for CDU budget breakdown in advanced EUV lithography

    Science.gov (United States)

    Nikolsky, Peter; Strolenberg, Chris; Nielsen, Rasmus; Nooitgedacht, Tjitte; Davydova, Natalia; Yang, Greg; Lee, Shawn; Park, Chang-Min; Kim, Insung; Yeo, Jeong-Ho

    2012-11-01

    As the ITRS Critical Dimension Uniformity (CDU) specification shrinks, semiconductor companies need to maintain a high yield of good wafers per day and a high performance (and hence market value) of finished products. This cannot be achieved without continuous analysis and improvement of on-product CDU as one of the main drivers for process control and optimization with better understanding of main contributors from the litho cluster: mask, process, metrology and scanner. In this paper we will demonstrate a study of mask CDU characterization and its impact on CDU Budget Breakdown (CDU BB) performed for an advanced EUV lithography with 1D and 2D feature cases. We will show that this CDU contributor is one of the main differentiators between well-known ArFi and new EUV CDU budgeting principles. We found that reticle contribution to intrafield CDU should be characterized in a specific way: mask absorber thickness fingerprints play a role comparable with reticle CDU in the total reticle part of the CDU budget. Wafer CD fingerprints, introduced by this contributor, may or may not compensate variations of mask CD's and hence influence on total mask impact on intrafield CDU at the wafer level. This will be shown on 1D and 2D feature examples in this paper. Also mask stack reflectivity variations should be taken into account: these fingerprints have visible impact on intrafield CDs at the wafer level and should be considered as another contributor to the reticle part of EUV CDU budget. We observed also MEEF-through-field fingerprints in the studied EUV cases. Variations of MEEF may also play a role for the total intrafield CDU and may be taken into account for EUV Lithography. We characterized MEEF-through-field for the reviewed features, the results to be discussed in our paper, but further analysis of this phenomenon is required. This comprehensive approach to characterization of the mask part of EUV CDU characterization delivers an accurate and integral CDU Budget

  12. Past and future challenges from a display mask writer perspective

    Science.gov (United States)

    Ekberg, Peter; von Sydow, Axel

    2012-06-01

    Since its breakthrough, the liquid crystal technology has continued to gain momentum and the LCD is today the dominating display type used in desktop monitors, television sets, mobile phones as well as other mobile devices. To improve production efficiency and enable larger screen sizes, the LCD industry has step by step increased the size of the mother glass used in the LCD manufacturing process. Initially the mother glass was only around 0.1 m2 large, but with each generation the size has increased and with generation 10 the area reaches close to 10 m2. The increase in mother glass size has in turn led to an increase in the size of the photomasks used - currently the largest masks are around 1.6 × 1.8 meters. A key mask performance criterion is the absence of "mura" - small systematic errors captured only by the very sensitive human eye. To eliminate such systematic errors, special techniques have been developed by Micronic Mydata. Some mura suppressing techniques are described in this paper. Today, the race towards larger glass sizes has come to a halt and a new race - towards higher resolution and better image quality - is ongoing. The display mask is therefore going through a change that resembles what the semiconductor mask went through some time ago: OPC features are introduced, CD requirements are increasing sharply and multi tone masks (MTMs) are widely used. Supporting this development, Micronic Mydata has introduced a number of compensation methods in the writer, such as Z-correction, CD map and distortion control. In addition, Micronic Mydata MMS15000, the world's most precise large area metrology tool, has played an important role in improving mask placement quality and is briefly described in this paper. Furthermore, proposed specifications and system architecture concept for a new generation mask writers - able to fulfill future image quality requirements - is presented in this paper. This new system would use an AOD/AOM writing engine and be

  13. HIGH PERFORMANCE PIAA CORONAGRAPHY WITH COMPLEX AMPLITUDE FOCAL PLANE MASKS

    International Nuclear Information System (INIS)

    Guyon, Olivier; Martinache, Frantz; Belikov, Ruslan; Soummer, Remi

    2010-01-01

    We describe a coronagraph approach where the performance of a Phase-Induced Amplitude Apodization (PIAA) coronagraph is improved by using a partially transmissive phase-shifting focal plane mask and a Lyot stop. This approach combines the low inner working angle offered by phase mask coronagraphy, the full throughput and uncompromized angular resolution of the PIAA approach, and the design flexibility of Apodized Pupil Lyot Coronagraph. A PIAA complex mask coronagraph (PIAACMC) is fully described by the focal plane mask size, or, equivalently, its complex transmission which ranges from 0 (opaque) to -1 (phase shifting). For all values of the transmission, the PIAACMC theoretically offers full on-axis extinction and 100% throughput at large angular separations. With a pure phase focal plane mask (complex transmission = -1), the PIAACMC offers 50% throughput at 0.64 λ/D while providing total extinction of an on-axis point source. This performance is very close to the 'fundamental performance limit' of coronagraphy derived from first principles. For very high contrast level, imaging performance with PIAACMC is in practice limited by the angular size of the on-axis target (usually a star). We show that this fundamental limitation must be taken into account when choosing the optimal value of the focal plane mask size in the PIAACMC design. We show that the PIAACMC enables visible imaging of Jupiter-like planets at ∼1.2 λ/D from the host star, and can therefore offer almost three times more targets than a PIAA coronagraph optimized for this type of observation. We find that for visible imaging of Earth-like planets, the PIAACMC gain over a PIAA is probably much smaller, as coronagraphic performance is then strongly constrained by stellar angular size. For observations at 'low' contrast (below ∼ 10 8 ), the PIAACMC offers significant performance enhancement over PIAA. This is especially relevant for ground-based high contrast imaging systems in the near-IR, where

  14. Noise frame duration, masking potency and whiteness of temporal noise.

    Science.gov (United States)

    Kukkonen, Heljä; Rovamo, Jyrki; Donner, Kristian; Tammikallio, Marja; Raninen, Antti

    2002-09-01

    Because of the limited contrast range, increasing the duration of the noise frame is often the only option for increasing the masking potency of external, white temporal noise. This, however, reduces the high-frequency cutoff beyond which noise is no longer white. This study was conducted to determine the longest noise frame duration that produces the strongest masking effect and still mimics white noise on the detection of sinusoidal flicker. Contrast energy thresholds (E(th)) were measured for flicker at 1.25 to 20 Hz in strong, purely temporal (spatially uniform), additive, external noise. The masking power of white external noise, characterized by its spectral density at zero frequency N0, increases with the duration of the noise frame. For short noise frame durations, E(th) increased in direct proportion to N0, keeping the nominal signal-to-noise ratio [SNR = (E(th)/N0)(0.5)] constant at threshold. The masking effect thus increased with the duration of the noise frame and the noise mimicked white noise. When noise frame duration and N0 increased further, the nominal SNR at threshold started to decrease, indicating that noise no longer mimicked white noise. The minimum number of noise frames per flicker cycle needed to mimic white noise decreased with increasing flicker frequency from 8.3 at 1.25 Hz to 1.6 at 20 Hz. The critical high-frequency cutoff of detection-limiting temporal noise in terms of noise frames per signal cycle depends on the temporal frequency of the signal. This is opposite to the situation in the spatial domain and must be taken into consideration when temporal signals are masked with temporal noise.

  15. Techniques of preoxygenation in patients with ineffective face mask seal

    Directory of Open Access Journals (Sweden)

    Pankaj Kundra

    2013-01-01

    Full Text Available Background: Ineffective face mask seal is the most common cause for suboptimal pre-oxygenation. Room air entrainment can be more with vital capacity (VC breaths when the mask is not a tight fit. Aims: This study was designed to compare 5 min tidal volume (TV breathing and eight VC breaths in patients with ineffective face mask seal. Methods: Twenty eight ASA I adults with ineffective face mask seal were randomized to breathe 100% oxygen at normal TV for 5 min (Group TV and eight VC breaths (Group VC in a cross over manner through circle system at 10 L/min. End tidal oxygen concentration (EtO 2 and arterial blood gas analysis was performed to evaluate oxygenation with each technique. Statistical Analysis: Data were analysed using SPSS statistical software, version 16. Friedman′s two-way analysis of variance by ranks was used for non-parametric data. Results: Significant increase in EtO 2 (median 90 and PaO 2 (228.85 was seen in group TV when compared to group VC (EtO 2 median 85, PaO 2 147.65, P<0.05. Mean total ventilation volume in 1 min in group VC was 9.4±3.3 L/min and more than fresh gas flow (10 L/min in seven patients. In group TV, the fresh gas flow (50 L/5 min was sufficient at normal TV (mean total ventilation in 5 min 36.7±6.3 L/min. Conclusions: TV breathing for 5 min provides better pre-oxygenation in patients with ineffective mask seal with fresh gas flow of 10 L/min delivered through a circle system.

  16. The imaging performance of flash memory masks characterized with AIMS

    Science.gov (United States)

    van Setten, Eelco; Wismans, Onno; Grim, Kees; Finders, Jo; Dusa, Mircea; Birkner, Robert; Richter, Rigo; Scherübl, Thomas

    2009-04-01

    Flash memory is an important driver of the lithography roadmap, with its dramatic acceleration in dimensional shrink, pushing for ever smaller feature sizes. The introduction of hyper-NA immersion lithography has brought the 45nm node and below within reach for memory makers using single exposure. At these feature sizes mask topology and the material properties of the film stack on the mask play an important role on imaging performance. Furthermore, the break up of the array pitch regularity in the NAND-type flash memory cell by two thick wordlines and a central space, leads to feature-center placement (overlay) errors, that are inherent to the design. An integral optimization approach is needed to mitigate these effects and to control both the CD and placement errors tightly. In this paper we will show that aerial image measurements at mask-level are useful for characterizing the gate layer of a NAND-Flash design before exposure. The aerial image measurements are performed with the AIMSTM 45-193i. and compared to CD measurements on the wafer obtained with an XT:1900Gi hyper-NA immersion system. An excellent correlation is demonstrated for feature-center placement errors and CD variations across the mask (see Figure 1) for several features in the gate layer down to 40nm half pitch. This shows the potential to use aerial image measurements at mask-level in combination with correction techniques on the photomask, like the CDC200 tool in combination with exposure tool correction techniques, such as DoseMapperTM, to improve both across field and across wafer CD uniformity of critical layers.

  17. Evaluating EUV mask pattern imaging with two EUV microscopes

    International Nuclear Information System (INIS)

    Goldberg, Kenneth A.; Takase, Kei; Naulleau, Patrick P.; Han, Hakseung; Barty, Anton; Kinoshita, Hiroo; Hamamoto, Kazuhiro

    2008-01-01

    Aerial image measurement plays a key role in the development of patterned reticles for each generation of lithography. Studying the field transmitted (reflected) from EUV masks provides detailed information about potential disruptions caused by mask defects, and the performance of defect repair strategies, without the complications of photoresist imaging. Furthermore, by measuring the continuously varying intensity distribution instead of a thresholded, binary resist image, aerial image measurement can be used as feedback to improve mask and lithography system modeling methods. Interest in EUV, at-wavelength, aerial image measurement lead to the creation of several research tools worldwide. These tools are used in advanced mask development work, and in the evaluation of the need for commercial at-wavelength inspection tools. They describe performance measurements of two such tools, inspecting the same EUV mask in a series of benchmarking tests that includes brightfield and darkfield patterns. One tool is the SEMATECH Berkeley Actinic Inspection Tool (AIT) operating on a bending magnet beamline at Lawrence Berkeley National Laboratory's Advanced Light Source. The AIT features an EUV Fresnel zoneplate microscope that emulates the numerical aperture of a 0.25-NA stepper, and projects the aerial image directly onto a CCD camera, with 700x magnification. The second tool is an EUV microscope (EUVM) operating at the NewSUBARU synchrotron in Hyogo, Japan. The NewSUBARU tool projects the aerial image using a reflective, 30x Schwarzschild objective lens, followed by a 10-200x x-ray zooming tube. The illumination conditions and the imaging etendue are different for the two tools. The benchmarking measurements were used to determine many imaging and performance properties of the tools, including resolution, modulation transfer function (MTF), aberration magnitude, aberration field-dependence (including focal-plane tilt), illumination uniformity, line-edge roughness, and flare

  18. The Q Continuum: Encounter with the Cloud Mask

    Science.gov (United States)

    Ackerman, S. A.; Frey, R.; Holz, R.; Philips, C.; Dutcher, S.

    2017-12-01

    We are developing a common cloud mask for MODIS and VIIRS observations, referred to as the MODIS VIIRS Continuity Mask (MVCM). Our focus is on extending the MODIS-heritage cloud detection approach in order to generate appropriate climate data records for clouds and climate studies. The MVCM is based on heritage from the MODIS cloud mask (MOD35 and MYD35) and employs a series of tests on MODIS reflectances and brightness temperatures. Cloud detection is based on contrasts (i.e., cloud versus background surface) at pixel resolution. The MVCM follows the same approach. These cloud masks use multiple cloud detection tests to indicate the confidence level that the observation is of a clear-sky scene. The outcome of a test ranges from 0 (cloudy) to 1 (clear-sky scene). Because of overlap in the sensitivities of the various spectral tests to the type of cloud, each test is considered in one of several groups. The final cloud mask is determined from the product of the minimum confidence of each group and is referred to as the Q value as defined in Ackerman et al (1998). In MOD35 and MYD35 processing, the Q value is not output, rather predetermined Q values determine the result: If Q ≥ .99 the scene is clear; .95 ≤ Q laws of physics are followed, at least according to normal human notions. Using CALIOP as representing truth, a receiver operating characteristic curve (ROC) will be analyzed to determine the optimum Q for various scenes and seasons, thus providing a continuum of discriminating thresholds.

  19. Health care workers' influenza vaccination: motivations and mandatory mask policy.

    Science.gov (United States)

    Dorribo, V; Lazor-Blanchet, C; Hugli, O; Zanetti, G

    2015-12-01

    Vaccination of health care workers (HCW) against seasonal influenza (SI) is recommended but vaccination rate rarely reach >30%. Vaccination coverage against 2009 pandemic influenza (PI) was 52% in our hospital, whilst a new policy requiring unvaccinated HCW to wear a mask during patient care duties was enforced. To investigate the determinants of this higher vaccination acceptance for PI and to look for an association with the new mask-wearing policy. A retrospective cohort study, involving HCW of three critical departments of a 1023-bed, tertiary-care university hospital in Switzerland. Self-reported 2009-10 SI and 2009 PI vaccination statuses, reasons and demographic data were collected through a literature-based questionnaire. Descriptive statistics, uni- and multivariate analyses were then performed. There were 472 respondents with a response rate of 54%. Self-reported vaccination acceptance was 64% for PI and 53% for SI. PI vaccination acceptance was associated with being vaccinated against SI (OR 9.5; 95% CI 5.5-16.4), being a physician (OR 7.7; 95% CI 3.1-19.1) and feeling uncomfortable wearing a mask (OR 1.7; 95% CI 1.0-2.8). Main motives for refusing vaccination were: preference for wearing a surgical mask (80% for PI, not applicable for SI) and concerns about vaccine safety (64%, 50%) and efficacy (44%, 35%). The new mask-wearing policy was a motivation for vaccination but also offered an alternative to non-compliant HCW. Concerns about vaccine safety and efficiency and self-interest of health care workers are still main determinants for influenza vaccination acceptance. Better incentives are needed to encourage vaccination amongst non-physician HCW. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Increased masked hypertension prevalence in patients with obesity.

    Science.gov (United States)

    Özkan, Selçuk; Ata, Naim; Yavuz, Bunyamin

    2018-02-08

    Masked hypertension is associated with an increased risk for cardiovascular conditions. The aim of the study was to evaluate the relationship obesity parameters, including body weight, waist circumference, and body mass index. The study group consisted of 251 consecutive outpatient subjects without overt hypertension. Subjects were classified according to BMI. After a complete medical history and laboratory examination, patients' height, weight, waist circumference heart rate, and office blood pressure were recorded. All subjects underwent ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of Masked hypertension was significantly higher in patients with obesity than controls (30.9% vs 5.7%, p < 0.001). Body mass index (33.2 ± 4.3 vs 25.1 ± 2.7 p < 0.001), waist circumference (98.5 ± 11.7 vs 86.8 ± 8.8, p < 0.001), and weight (86.5 ± 11.8 vs. 69 ± 9.1, p < 0.001) in patients with obesity were significantly higher than in patients with normal weight. Office Systolic BP (121.8 ± 4.4 vs 120.5 ± 4.78, p = 0.035), ambulatory daytime systolic BP (128.8 ± 8.9 vs 124.5 ± 7.4, p < 0.001), ambulatory daytime diastolic BP (73.9 ± 9.5 vs 71.5 ± 7.0, p = 0.019), ambulatory night-time systolic BP in patients with obesity was significantly higher than in patients with normal weight. This study demonstrated that masked hypertension prevalence is higher in patients with obesity than control patients. It can be suggested that predefining obesity might be helpful in early detection of masked hypertension.

  1. Psychophysical estimates of cochlear phase response: masking by harmonic complexes.

    Science.gov (United States)

    Lentz, J J; Leek, M R

    2001-12-01

    Harmonic complexes with identical component frequencies and amplitudes but different phase spectra may be differentially effective as maskers. Such harmonic waveforms, constructed with positive or negative Schroeder phases, have similar envelopes and identical long-term power spectra, but the positive Schroeder-phase waveform is typically a less effective masker than the negative Schroeder-phase waveform. These masking differences have been attributed to an interaction between the masker phase spectrum and the phase characteristic of the basilar membrane. To explore this relationship, the gradient of stimulus phase change across masker bandwidth was varied by systematically altering the Schroeder-phase algorithm. Observers detected a signal tone added in-phase to a single component of a masker whose frequencies ranged from 200 to 5000 Hz, with a fundamental frequency of 100 Hz. For signal frequencies of 1000-4000 Hz, differences in masking across the harmonic complexes could be as large as 5-10 dB for phase gradients changing by only 10%. The phase gradient that resulted in a minimum amount of masking varied with signal frequency, with low frequencies masked least effectively by stimuli with rapidly changing component phases and high frequencies masked by stimuli with more shallow phase gradients. A gammachirp filter was implemented to model these results, predicting the qualitative changes in curvature of the phase-byfrequency function estimated from the empirical data: In some cases, small modifications to the gammachirp filter produced better quantitative predictions of curvature changes across frequency, but this filter, as implemented here, was unable to accurately represent all the data.

  2. Neonatal mannequin comparison of the Upright self-inflating bag and snap-fit mask versus standard resuscitators and masks: leak, applied load and tidal volumes.

    Science.gov (United States)

    Rafferty, Anthony Richard; Johnson, Lucy; Davis, Peter G; Dawson, Jennifer Anne; Thio, Marta; Owen, Louise S

    2017-11-30

    Neonatal mask ventilation is a difficult skill to acquire and maintain. Mask leak is common and can lead to ineffective ventilation. The aim of this study was to determine whether newly available neonatal self-inflating bags and masks could reduce mask leak without additional load being applied to the face. Forty operators delivered 1 min episodes of mask ventilation to a mannequin using the Laerdal Upright Resuscitator, a standard Laerdal infant resuscitator (Laerdal Medical) and a T-Piece Resuscitator (Neopuff), using both the Laerdal snap-fit face mask and the standard Laerdal size 0/1 face mask (equivalent sizes). Participants were asked to use pressure sufficient to achieve 'appropriate' chest rise. Leak, applied load, airway pressure and tidal volume were measured continuously. Participants were unaware that load was being recorded. There was no difference in mask leak between resuscitation devices. Leak was significantly lower when the snap-fit mask was used with all resuscitation devices, compared with the standard mask (14% vs 37% leak, Pmask was preferred by 83% of participants. The device-mask combinations had no significant effect on applied load. The Laerdal Upright Resuscitator resulted in similar leak to the other resuscitation devices studied, and did not exert additional load to the face and head. The snap-fit mask significantly reduced overall leak with all resuscitation devices and was the mask preferred by participants. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Overcoming weak intrinsic depolarizing resonances with energy-jump

    International Nuclear Information System (INIS)

    Huang, H.; Ahrens, L.; Alessi, J.G.

    1997-01-01

    In the recent polarized proton runs in the AGS, a 5% partial snake was used successfully to overcome the imperfection depolarizing resonances. Polarized proton beam was accelerated up to the required RHIC injection energy of 25 GeV. However, significant amount of polarization was lost at 0+ν y , 12+ν y and 36+ν y , which is believed to be partially due to the coupling resonances. To overcome the coupling resonance, an energy-jump was generated by rapidly changing the beam circumference using the powerful AGS rf system. It clearly demonstrates that the novel energy-jump method can successfully overcome coupling resonances and weak intrinsic resonances

  4. Airway obstruction and gas leak during mask ventilation of preterm infants in the delivery room.

    LENUS (Irish Health Repository)

    2011-07-01

    Preterm infants with inadequate breathing receive positive pressure ventilation (PPV) by mask with variable success. The authors examined recordings of PPV given to preterm infants in the delivery room for prevalence of mask leak and airway obstruction.

  5. US EPA Regional Masks Web Service, US, 2015, US EPA, SEGS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web service contains the following map layers: masks and labels for EPA regions 1 through 10. Mask layers are drawn at all scales. Label layers draw at scales...

  6. Printed wax masks for 254 nm deep-UV pattering of PMMA-based microfluidics

    KAUST Repository

    Fan, Yiqiang; Liu, Yang; Li, Huawei; Foulds, Ian G.

    2012-01-01

    This paper reports a new technique for masking deep-UV exposure of poly(methyl methacrylate) (PMMA) using a printed wax mask. This technique provides an inexpensive and bulk fabrication method for PMMA structures. The technique involves the direct

  7. "Slit Mask Design for the Giant Magellan Telescope Multi-object Astronomical and Cosmological Spectrograph"

    Science.gov (United States)

    Williams, Darius; Marshall, Jennifer L.; Schmidt, Luke M.; Prochaska, Travis; DePoy, Darren L.

    2018-01-01

    The Giant Magellan Telescope Multi-object Astronomical and Cosmological Spectrograph (GMACS) is currently in development for the Giant Magellan Telescope (GMT). GMACS will employ slit masks with a usable diameter of approximately 0.450 m for the purpose of multi-slit spectroscopy. Of significant importance are the design constraints and parameters of the multi-object slit masks themselves as well as the means for mapping astronomical targets to physical mask locations. Analytical methods are utilized to quantify deformation effects on a potential slit mask due to thermal expansion and vignetting of target light cones. Finite element analysis (FEA) is utilized to simulate mask flexure in changing gravity vectors. The alpha version of the mask creation program for GMACS, GMACS Mask Simulator (GMS), a derivative of the OSMOS Mask Simulator (OMS), is introduced.

  8. Expression of the VP40 antigen from the Zaire ebolavirus in tobacco plants.

    Science.gov (United States)

    Monreal-Escalante, Elizabeth; Ramos-Vega, Abel A; Salazar-González, Jorge A; Bañuelos-Hernández, Bernardo; Angulo, Carlos; Rosales-Mendoza, Sergio

    2017-07-01

    The plant cell is able to produce the VP40 antigen from the Zaire ebolavirus , retaining the antigenicity and the ability to induce immune responses in BALB/c mice. The recent Ebola outbreak evidenced the need for having vaccines approved for human use. Herein we report the expression of the VP40 antigen from the Ebola virus as an initial effort in the development of a plant-made vaccine that could offer the advantages of being cheap and scalable, which is proposed to overcome the rapid need for having vaccines to deal with future outbreaks. Tobacco plants were transformed by stable DNA integration into the nuclear genome using the CaMV35S promoter and a signal peptide to access the endoplasmic reticulum, reaching accumulation levels up to 2.6 µg g -1 FW leaf tissues. The antigenicity of the plant-made VP40 antigen was evidenced by Western blot and an initial immunogenicity assessment in test animals that revealed the induction of immune responses in BALB/c mice following three weekly oral or subcutaneous immunizations at very low doses (125 and 25 ng, respectively) without accessory adjuvants. Therefore, this plant-based vaccination prototype is proposed as an attractive platform for the production of vaccines in the fight against Ebola virus disease outbreaks.

  9. Low-level pure-tone masking : a comparison of "tuning curves" obtained with simultaneous and forward masking

    NARCIS (Netherlands)

    Vogten, L.L.M.

    1978-01-01

    Simultaneous and forward pure-tone masking are compared, using a fixed-level probe of 20-ms and a 200-ms masker. For a 1-kHz probe of 30 dB SPL the required masker level Lm is measured as a function of the time interval ?t between masker offset and probe onset. When masker and probe have equal

  10. Characterization of the Apa antigen from M. avium subsp. paratuberculosis: a conserved Mycobacterium antigen that elicits a strong humoral response in cattle.

    Science.gov (United States)

    Gioffré, A; Echeverría-Valencia, G; Arese, A; Morsella, C; Garbaccio, S; Delgado, F; Zumárraga, M; Paolicchi, F; Cataldi, A; Romano, M I

    2009-12-15

    Johne's disease or paratuberculosis is widespread in almost all countries and remains difficult to eradicate. Nowadays, diagnosis of Mycobacterium avium subsp. paratuberculosis (MPTB) infection is one of the main concerns. In this work, we evaluated the expression, biochemical properties and antigenicity of the Apa antigen, encoded by the gene annotated as MAP1569, in the MPTB genome. We confirmed its expression in MPTB and its glycosylation by the ConA binding assay. Although the MPTB-Apa is not an immunodominant antigen, MPTB-infected cattle showed a strong humoral response to recombinant Apa by Western blot and ELISA. Milk was also a suitable sample to be tested by ELISA. We comparatively analysed the humoral cross-reactivity to the Apa from MPTB (MPTB-Apa) and the orthologue from Mycobacterium tuberculosis (MT-Apa, identical to that from Mycobacterium bovis) in both infected and control cows. Response of M. bovis- and MPTB-infected animals against MT-Apa was similar (P=0.6985) but the response of the M. bovis-infected ones to MPTB-Apa was differential, being significantly diminished (PApa stimulation in the IFNgamma release assay, we found no significant differences when compared infected herds with non-infected ones (P=0.34). This antigen, in contrast to bovine Purified Protein Derivative (PPDb), was strongly represented in avian PPD (PPDa), as shown by the recognition of BALB/c mice hyperimmune sera against MPTB-Apa by Dot-blot immunoassay. We therefore demonstrated the antigenicity of Apa in MPTB-infected animals and a differential response to the recombinant antigen when compared to M. bovis-infected animals. These traits herein described, added to the usefulness of milk samples to detect IgG anti-Apa, could be important for routine screening in dairy cattle, considering a multiantigenic approach to overcome the lack of immunodominance.

  11. Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation.

    Science.gov (United States)

    Qureshi, Mosarrat J; Kumar, Manoj

    2018-03-15

    Providing effective positive pressure ventilation is considered to be the single most important component of successful neonatal resuscitation. Ventilation is frequently initiated manually with bag and face mask (BMV) followed by endotracheal intubation if respiratory depression continues. These techniques may be difficult to perform successfully resulting in prolonged resuscitation or neonatal asphyxia. The laryngeal mask airway (LMA) may achieve initial ventilation and successful resuscitation faster than a bag-mask device or endotracheal intubation. Among newborns requiring positive pressure ventilation for cardio-pulmonary resuscitation, is LMA more effective than BMV or endotracheal intubation for successful resuscitation? When BMV is either insufficient or ineffective, is effective positive pressure ventilation and successful resuscitation achieved faster with the LMA compared to endotracheal intubation? We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2017, Issue 1), MEDLINE via PubMed (1966 to 15 February 2017), Embase (1980 to 15 February 2017), and CINAHL (1982 to 15 February 2017). We also searched clinical trials registers, conference proceedings, and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. We included randomised and quasi-randomised controlled trials that compared LMA for neonatal resuscitation with either BMV or endotracheal intubation and reported on any outcomes related to neonatal resuscitation specified in this review. Two review authors independently evaluated studies for risk of bias assessments, and extracted data using Cochrane Neonatal criteria. Categorical treatment effects were described as relative risks and continuous treatment effects were described as the mean difference, with 95% confidence intervals (95% CI) of estimates. We included seven trials that involved a total of 794 infants. Five

  12. FAST COMMUNICATION: A PDE Based Two Level Model of the Masking Property of the Human Ear

    OpenAIRE

    Xin, Jack; Qi, Yingyong

    2003-01-01

    Human ear has the masking property that certain audible sound becomes inaudible in the presence of another sound. Masking is quantified by the raised threshold from the absolute hearing threshold in quiet. It is of scientific and practical importance to compute masking thresholds. Empirical models on masking have applications in low bit rate digital music compression. A first principle based two level model is developed with partial differential equation (PDE) at the periphe...

  13. Overcoming artificial spatial correlations in simulations of superstructure domain growth with parallel Monte Carlo algorithms

    International Nuclear Information System (INIS)

    Schleier, W.; Besold, G.; Heinz, K.

    1992-01-01

    The authors study the applicability of parallelized/vectorized Monte Carlo (MC) algorithms to the simulation of domain growth in two-dimensional lattice gas models undergoing an ordering process after a rapid quench below an order-disorder transition temperature. As examples they consider models with 2 x 1 and c(2 x 2) equilibrium superstructures on the square and rectangular lattices, respectively. They also study the case of phase separation ('1 x 1' islands) on the square lattice. A generalized parallel checkerboard algorithm for Kawasaki dynamics is shown to give rise to artificial spatial correlations in all three models. However, only if superstructure domains evolve do these correlations modify the kinetics by influencing the nucleation process and result in a reduced growth exponent compared to the value from the conventional heat bath algorithm with random single-site updates. In order to overcome these artificial modifications, two MC algorithms with a reduced degree of parallelism ('hybrid' and 'mask' algorithms, respectively) are presented and applied. As the results indicate, these algorithms are suitable for the simulation of superstructure domain growth on parallel/vector computers. 60 refs., 10 figs., 1 tab

  14. Characterization of Leishmania Soluble Exo-Antigen

    National Research Council Canada - National Science Library

    Cui, Liwang

    2003-01-01

    .... Vaccine development is the ultimate solution for this problem. Our previous research indicates that Leishmania parasites secrete, excrete, or shed antigens into the medium during in vitro culture...

  15. Binding of hydrophobic antigens to surfaces

    DEFF Research Database (Denmark)

    2017-01-01

    A first aspect of the present invention is a method of detecting antibodies comprising the steps of: i) providing a first group of beads comprising a surface modified with C1-C10 alkyl groups comprising amine, ammonium, ether and/or hydroxyl groups, ii) contacting said first group of beads......-antigen-antibody conjugates, and v) detecting said bead-antigen-antibody conjugates. Further aspects include an antibody detection kit, a bead-antigen conjugate and a composition comprising at least two different groups of bead-antigen-conjugates....

  16. Overcoming Residents Opportunity Apathy in Danish Social Housing Democracy

    DEFF Research Database (Denmark)

    Bertelsen, Olav W.

    2014-01-01

    In this paper, I discuss how various technologies can support democratic collaboration in the social housing sector in Denmark, and help overcome opportunity apathy. I exemplify the discussion with an ongoing process of strategy development, in a Danish housing organization....

  17. Overcoming Family Planning Challenges in Africa: Toward Meeting ...

    African Journals Online (AJOL)

    USER

    Overcoming Family Planning Challenges in Africa: Toward Meeting. Unmet Need ... The challenges posed are greater in ... Gaps in meeting women's needs persist especially ..... WHO. Everybody's business: Strengthening health systems to.

  18. Method to make a single-step etch mask for 3D monolithic nanostructures

    NARCIS (Netherlands)

    Grishina, Diana; Harteveld, Cornelis A.M.; Woldering, L.A.; Vos, Willem L.

    2015-01-01

    Current nanostructure fabrication by etching is usually limited to planar structures as they are defined by a planar mask. The realization of three-dimensional (3D) nanostructures by etching requires technologies beyond planar masks. We present a method for fabricating a 3D mask that allows one to

  19. Structure and thermal analysis of the water cooling mask at NSRL front end

    International Nuclear Information System (INIS)

    Zhao Feiyun; Xu Chaoyin; Wang Qiuping; Wang Naxiu

    2003-01-01

    A water cooling mask is an important part of the front end, usually used for absorbing high power density synchrotron radiation to protect the apparatus from being destroyed by heat load. This paper presents the structure of the water cooling mask and the thermal analysis results of the mask block at NSRL using Program ANSYS5.5

  20. A Particle-In-Cell approach to particle flux shaping with a surface mask

    Directory of Open Access Journals (Sweden)

    G. Kawamura

    2017-08-01

    Full Text Available The Particle-In-Cell simulation code PICS has been developed to study plasma in front of a surface with two types of masks, step-type and roof-type. Parameter scans with regard to magnetic field angle, electron density, and mask height were carried out to understand their influence on ion particle flux distribution on a surface. A roof-type mask with a small mask height yields short decay length in the flux distribution which is consistent with that estimated experimentally. A roof-type mask with a large height yields very long decay length and the flux value does not depend on a mask height or an electron density, but rather on a mask length and a biasing voltage of the surface. Mask height also changes the flux distribution apart from the mask because of the shading effect of the mask. Electron density changes the distribution near the mask edge according to the Debye length. Dependence of distribution on parameters are complicated especially for a roof-type mask, and simulation study with various parameters are useful to understand the physical reasons of dependence and also is useful as a tool for experiment studies.

  1. Filter penetration and breathing resistance evaluation of respirators and dust masks.

    Science.gov (United States)

    Ramirez, Joel; O'Shaughnessy, Patrick

    2017-02-01

    The primary objective of this study was to compare the filter performance of a representative selection of uncertified dust masks relative to the filter performance of a set of NIOSH-approved N95 filtering face-piece respirators (FFRs). Five different models of commercially available dust masks were selected for this study. Filter penetration of new dust masks was evaluated against a sodium chloride aerosol. Breathing resistance (BR) of new dust masks and FFRs was then measured for 120 min while challenging the dust masks and FFRs with Arizona road dust (ARD) at 25°C and 30% relative humidity. Results demonstrated that a wide range of maximum filter penetration was observed among the dust masks tested in this study (3-75% at the most penetrating particle size (p masks did not vary greatly (8-13 mm H 2 O) but were significantly different (p mask. Microscopic analysis of the external layer of each dust mask and FFR suggests that different collection media in the external layer influences the development of the dust layer and therefore affects the increase in BR differently between the tested models. Two of the dust masks had penetration values masks, those with penetration > 15%, had quality factors ranging between 0.04-0.15 primarily because their initial BR remained relatively high. These results indicate that some dust masks analysed during this research did not have an expected very low BR to compensate for their high penetration.

  2. 76 FR 9984 - Airworthiness Directives; B/E Aerospace, Continuous Flow Passenger Oxygen Mask Assembly, Part...

    Science.gov (United States)

    2011-02-23

    ..., Continuous Flow Passenger Oxygen Mask Assembly, Part Numbers 174006-(), 174080-(), 174085-(), 174095... manufacturer and part number of the oxygen mask assemblies installed, an inspection to determine the manufacturing date and modification status if certain oxygen mask assemblies are installed, and corrective...

  3. 37 CFR 211.2 - Recordation of documents pertaining to mask works.

    Science.gov (United States)

    2010-07-01

    ... pertaining to mask works. 211.2 Section 211.2 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES MASK WORK PROTECTION § 211.2 Recordation of documents pertaining to mask works. The conditions prescribed in § 201.4 of this chapter for recordation of transfers...

  4. 76 FR 41669 - Airworthiness Directives; B/E Aerospace, Continuous Flow Passenger Oxygen Mask Assembly, Part...

    Science.gov (United States)

    2011-07-15

    ... Airworthiness Directives; B/E Aerospace, Continuous Flow Passenger Oxygen Mask Assembly, Part Numbers 174006... manufacturer and part number of the oxygen mask assemblies installed, an inspection to determine the manufacturing date and modification status if certain oxygen mask assemblies are installed, and corrective...

  5. 42 CFR 84.75 - Half-mask facepieces, full facepieces, mouthpieces; fit; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Half-mask facepieces, full facepieces, mouthpieces... RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.75 Half-mask facepieces, full facepieces, mouthpieces; fit; minimum requirements. (a) Half-mask facepieces and full facepieces shall be...

  6. 37 CFR 211.4 - Registration of claims of protection in mask works.

    Science.gov (United States)

    2010-07-01

    ... protection in mask works. 211.4 Section 211.4 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES MASK WORK PROTECTION § 211.4 Registration of claims of protection in mask works. (a) General. This section prescribes conditions for the registration of claims of...

  7. 37 CFR 211.6 - Methods of affixation and placement of mask work notice.

    Science.gov (United States)

    2010-07-01

    ... placement of mask work notice. 211.6 Section 211.6 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES MASK WORK PROTECTION § 211.6 Methods of affixation and placement of mask work notice. (a) General. (1) This section specifies methods of affixation and placement...

  8. Evaluation of protection provided by air purifying half and full-face masks as worn

    International Nuclear Information System (INIS)

    Murata, Mikio; Ikezawa, Yoshio; Yoshida, Yoshikazu

    1979-01-01

    For selecting good-performing masks and estimating the protection provided by the masks, the leakage has been measured for six types of half mask and three types of full-face mask as worn. The cloud of submicron sodium chloride particles was generated within a test hood in which the subject wore his mask. The air sampled from inside the mask with a miniature pump was assessed by a flame photometer. The leakage was measured under four simulated working conditions such as normal breathing, smiling, moving head, and talking. The measured protection factors (defined as the ratio of the concentration of the test cloud outside the mask to that inside the mask) widely distributed from 10 to 3,300 for the half masks and from 100 to 3,300 for the full-face masks, depending on the persons and the working conditions. The values characterising the distribution of the protection factor for each mask are summarized. Based on these values, the performance of each mask and the effects of working conditions on the protection are discussed. (author)

  9. Exploiting Small Leakages in Masks to Turn a Second-Order Attack into a First-Order Attack and Improved Rotating Substitution Box Masking with Linear Code Cosets

    Science.gov (United States)

    DeTrano, Alexander; Karimi, Naghmeh; Karri, Ramesh; Guo, Xiaofei; Carlet, Claude; Guilley, Sylvain

    2015-01-01

    Masking countermeasures, used to thwart side-channel attacks, have been shown to be vulnerable to mask-extraction attacks. State-of-the-art mask-extraction attacks on the Advanced Encryption Standard (AES) algorithm target S-Box recomputation schemes but have not been applied to scenarios where S-Boxes are precomputed offline. We propose an attack targeting precomputed S-Boxes stored in nonvolatile memory. Our attack targets AES implemented in software protected by a low entropy masking scheme and recovers the masks with 91% success rate. Recovering the secret key requires fewer power traces (in fact, by at least two orders of magnitude) compared to a classical second-order attack. Moreover, we show that this attack remains viable in a noisy environment or with a reduced number of leakage points. Eventually, we specify a method to enhance the countermeasure by selecting a suitable coset of the masks set. PMID:26491717

  10. Who is that masked educator? Deconstructing the teaching and learning processes of an innovative humanistic simulation technique.

    Science.gov (United States)

    McAllister, Margaret; Searl, Kerry Reid; Davis, Susan

    2013-12-01

    Simulation learning in nursing has long made use of mannequins, standardized actors and role play to allow students opportunity to practice technical body-care skills and interventions. Even though numerous strategies have been developed to mimic or amplify clinical situations, a common problem that is difficult to overcome in even the most well-executed simulation experiences, is that students may realize the setting is artificial and fail to fully engage, remember or apply the learning. Another problem is that students may learn technical competence but remain uncertain about communicating with the person. Since communication capabilities are imperative in human service work, simulation learning that only achieves technical competence in students is not fully effective for the needs of nursing education. Furthermore, while simulation learning is a burgeoning space for innovative practices, it has been criticized for the absence of a basis in theory. It is within this context that an innovative simulation learning experience named "Mask-Ed (KRS simulation)", has been deconstructed and the active learning components examined. Establishing a theoretical basis for creative teaching and learning practices provides an understanding of how, why and when simulation learning has been effective and it may help to distinguish aspects of the experience that could be improved. Three conceptual theoretical fields help explain the power of this simulation technique: Vygotskian sociocultural learning theory, applied theatre and embodiment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. A new suction mask to reduce leak during neonatal resuscitation: a manikin study.

    Science.gov (United States)

    Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G

    2016-09-01

    Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Comparison of the OxyMask and Venturi mask in the delivery of supplemental oxygen: Pilot study in oxygen-dependent patients

    Science.gov (United States)

    Beecroft, Jaime M; Hanly, Patrick J

    2006-01-01

    BACKGROUND: The OxyMask (Southmedic Inc, Canada) is a new face mask for oxygen delivery that uses a small ‘diffuser’ to concentrate and direct oxygen toward the mouth and nose. The authors hypothesized that this unique design would enable the OxyMask to deliver oxygen more efficiently than a Venturi mask (Hudson RCI, USA) in patients with chronic hypoxemia. METHODS: Oxygen-dependent patients with chronic, stable respiratory disease were recruited to compare the OxyMask and Venturi mask in a randomized, single-blind, cross-over design. Baseline blood oxygen saturation (SaO2) was established breathing room air, followed in a random order by supplemental oxygen through the OxyMask or Venturi mask. Oxygen delivery was titrated to maintain SaO2 4% to 5% and 8% to 9% above baseline for two separate 30 min periods of stable breathing. Oxygen flow rate, partial pressure of inspired and expired oxygen (PO2) and carbon dioxide (PCO2), minute ventilation, heart rate, nasal and oral breathing, SaO2 and transcutaneous PCO2 were collected continuously. The study was repeated following alterations to the OxyMask design, which improved clearance of carbon dioxide. RESULTS: Thirteen patients, aged 28 to 79 years, were studied initially using the original OxyMask. Oxygen flow rate was lower, inspired PO2 was higher and expired PO2 was lower while using the OxyMask. Minute ventilation and inspired and expired PCO2 were significantly higher while using the OxyMask, whereas transcutaneous PCO2, heart rate and the ratio of nasal to oral breathing did not change significantly throughout the study. Following modification of the OxyMask, 13 additional patients, aged 18 to 79 years, were studied using the same protocol. The modified OxyMask provided a higher inspired PO2 at a lower flow rate, without evidence of carbon dioxide retention. CONCLUSIONS: Oxygen is delivered safely and more efficiently by the OxyMask than by the Venturi mask in stable oxygen-dependent patients. PMID:16896425

  13. Study of a coronagraphic mask using evanescent waves.

    Science.gov (United States)

    Buisset, Christophe; Rabbia, Yves; Lepine, Thierry; Alagao, Mary-Angelie; Ducrot, Elsa; Poshyachinda, Saran; Soonthornthum, Boonrucksar

    2017-04-03

    The evanescent wave coronagraph (EvWaCo) is a specific kind of band-limited coronagraph using the frustrated total internal reflection phenomenon to produce the coronagraphic effect (removing starlight from the image plane in order to make the stellar environment detectable). In this paper, we present a theoretical and experimental study of the EvWaCo coronagraphic mask. First, we calculate the theoretical transmission and we show that this mask is partially achromatic. Then, we present the experimental results obtained in unpolarized light at the wavelength λ≈900 nm and relative spectral bandwidth Δλ/λ≈6%. In particular, we show that the coronagraph provides a contrast down to a few 10-6 at an angular distance of about ten Airy radii.

  14. Speckle reduction in digital holography with resampling ring masks

    Science.gov (United States)

    Zhang, Wenhui; Cao, Liangcai; Jin, Guofan

    2018-01-01

    One-shot digital holographic imaging has the advantages of high stability and low temporal cost. However, the reconstruction is affected by the speckle noise. Resampling ring-mask method in spectrum domain is proposed for speckle reduction. The useful spectrum of one hologram is divided into several sub-spectra by ring masks. In the reconstruction, angular spectrum transform is applied to guarantee the calculation accuracy which has no approximation. N reconstructed amplitude images are calculated from the corresponding sub-spectra. Thanks to speckle's random distribution, superimposing these N uncorrelated amplitude images would lead to a final reconstructed image with lower speckle noise. Normalized relative standard deviation values of the reconstructed image are used to evaluate the reduction of speckle. Effect of the method on the spatial resolution of the reconstructed image is also quantitatively evaluated. Experimental and simulation results prove the feasibility and effectiveness of the proposed method.

  15. Gingival mask: A case report on enhancing smiles

    Directory of Open Access Journals (Sweden)

    Aashritha Shenava

    2014-01-01

    Full Text Available Periodontal attachment loss in the maxillary anterior region can often lead to esthetic and functional clinical problems including disproportional and elongated clinical crowns and visible interdental embrasures. Gingival replacement prosthesis has historically been used to replace lost tissue. A gingival mask is an easily constructed and practical device to optimize the esthetic and functional outcome in these special situations while permitting cleansibility of the prosthesis and supporting tissues. This is a case report of a young female patient treated using silicon gingival veneer with a 2-year follow-up. The silicon gingival mask has enabled the patient to regain her lost smile and face people with newly found confidence also enhancing the esthetic appearance. Virtually, no problem was encountered during the 2 years of usage of the veneer and the patient continues to use it comfortably.

  16. Neurosarcoidosis-associated central diabetes insipidus masked by adrenal insufficiency.

    Science.gov (United States)

    Non, Lemuel; Brito, Daniel; Anastasopoulou, Catherine

    2015-01-22

    Central diabetes insipidus (CDI) is an infrequent complication of neurosarcoidosis (NS). Its presentation may be masked by adrenal insufficiency (AI) and uncovered by subsequent steroid replacement. A 45-year-old woman with a history of NS presented 2 weeks after abrupt cessation of prednisone with nausea, vomiting, decreased oral intake and confusion. She was diagnosed with secondary AI and intravenous hydrocortisone was promptly begun. Over the next few days, however, the patient developed severe thirst and polyuria exceeding 6 L of urine per day, accompanied by hypernatraemia and hypo-osmolar urine. She was presumed to have CDI due to NS, and intranasal desmopressin was administered. This eventually normalised her urine output and serum sodium. The patient was discharged improved on intranasal desmopressin and oral prednisone. AI may mask the manifestation of CDI because low serum cortisol impairs renal-free water clearance. Steroid replacement reverses this process and unmasks an underlying CDI. 2015 BMJ Publishing Group Ltd.

  17. The JWST/NIRCam Coronagraph: Mask Design and Fabrication

    Science.gov (United States)

    Krista, John E.; Balasubramanian, Kunjithapatha; Beichman, Charles A.; Echternach, Pierre M.; Green, Joseph J.; Liewer, Kurt M.; Muller, Richard E.; Serabyn, Eugene; Shaklan, Stuart B.; Trauger, John T.; hide

    2009-01-01

    The NIRCam instrument on the James Webb Space Telescope will provide coronagraphic imaging from lambda =1-5 microns of high contrast sources such as extrasolar planets and circumstellar disks. A Lyot coronagraph with a variety of circular and wedge-shaped occulting masks and matching Lyot pupil stops will be implemented. The occulters approximate grayscale transmission profiles using halftone binary patterns comprising wavelength-sized metal dots on anti-reflection coated sapphire substrates. The mask patterns are being created in the Micro Devices Laboratory at the Jet Propulsion Laboratory using electron beam lithography. Samples of these occulters have been successfully evaluated in a coronagraphic testbed. In a separate process, the complex apertures that form the Lyot stops will be deposited onto optical wedges. The NIRCam coronagraph flight components are expected to be completed this year.

  18. Metal layer mask patterning by force microscopy lithography

    International Nuclear Information System (INIS)

    Filho, H.D. Fonseca; Mauricio, M.H.P.; Ponciano, C.R.; Prioli, R.

    2004-01-01

    The nano-lithography of a metallic surface in air by atomic force microscopy while operated in contact mode and equipped with a diamond tip is presented. The aluminum mask was prepared by thermal deposition on arsenic sulfide films. The analysis of the scratches performed by the tip on the metallic mask show that the depth of the lithographed pattern increases with the increase of the applied normal force. The scanning velocity is also shown to influence the AFM patterning process. As the scanning velocity increases, the scratch depth and width decreases. Nano-indentations performed with the diamond tip show that the plastically deformed surface increases with the increase of the duration of the applied force. The use of the nano-lithography method to create nano-structures is discussed

  19. Single photoresist masking for local porous Si formation

    International Nuclear Information System (INIS)

    Hourdakis, E; Nassiopoulou, A G

    2014-01-01

    A simple process for local electrochemical porous Si formation on a Si wafer using a photoresist mask was developed. In this respect, the AZ9260 photoresist from MicroChemicals was used, which is easily removed by simple immersion in acetone after the electrochemical process. The photoresist layer thickness and its adhesion to the Si substrate were optimized for increased etch resistance to the anodization solution. Using the above process, mesoporous Si layers as thick as 50 μm were locally formed on the Si wafer through the photoresist mask. The developed process paves the way towards a simple industrial batch Si technology process for the fabrication of mixed Si wafers containing local porous Si areas. These wafers are very interesting for future system-on-chip (SoC) applications, including RF analog/digital and sensors/electronics SoCs. (technical note)

  20. Ion distribution near a mask edge with arbitrary shape for VLSI IC applications

    International Nuclear Information System (INIS)

    Lutsch, A.G.K.; Oosthuizen, D.R.

    1985-01-01

    The profile of the mask edge during ion implantation determines the electrical field in the critical drain region of a MOS-transistor. Equal ion density lines are computed for various mask edges for the example of boron implanted into silicon at 70 keV. Four moments of the impurity depth distribution (without mask material are taken into consideration. Homogenisation and, therefore a higher noise immunity, can be obtained by the proper choice of the mask etching process. The influence of a too-thin mask material is also shown. (author)

  1. Accuracy and performance of 3D mask models in optical projection lithography

    Science.gov (United States)

    Agudelo, Viviana; Evanschitzky, Peter; Erdmann, Andreas; Fühner, Tim; Shao, Feng; Limmer, Steffen; Fey, Dietmar

    2011-04-01

    Different mask models have been compared: rigorous electromagnetic field (EMF) modeling, rigorous EMF modeling with decomposition techniques and the thin mask approach (Kirchhoff approach) to simulate optical diffraction from different mask patterns in projection systems for lithography. In addition, each rigorous model was tested for two different formulations for partially coherent imaging: The Hopkins assumption and rigorous simulation of mask diffraction orders for multiple illumination angles. The aim of this work is to closely approximate results of the rigorous EMF method by the thin mask model enhanced with pupil filtering techniques. The validity of this approach for different feature sizes, shapes and illumination conditions is investigated.

  2. Fabless company mask technology approach: fabless but not fab-careless

    Science.gov (United States)

    Hisamura, Toshiyuki; Wu, Xin

    2009-10-01

    There are two different foundry-fabless working models in the aspect of mask. Some foundries have in-house mask facility while others contract with merchant mask vendors. Significant progress has been made in both kinds of situations. Xilinx as one of the pioneers of fabless semiconductor companies has been continually working very closely with both merchant mask vendors and mask facilities of foundries in past many years, contributed well in both technology development and benefited from corporations. Our involvement in manufacturing is driven by the following three elements: The first element is to understand the new fabrication and mask technologies and then find a suitable design / layout style to better utilize these new technologies and avoid potential risks. Because Xilinx has always been involved in early stage of advanced technology nodes, this early understanding and adoption is especially important. The second element is time to market. Reduction in mask and wafer manufacturing cycle-time can ensure faster time to market. The third element is quality. Commitment to quality is our highest priority for our customers. We have enough visibility on any manufacturing issues affecting the device functionality. Good correlation has consistently been observed between FPGA speed uniformity and the poly mask Critical Dimension (CD) uniformity performance. To achieve FPGA speed uniformity requirement, the manufacturing process as well as the mask and wafer CD uniformity has to be monitored. Xilinx works closely with the wafer foundries and mask suppliers to improve productivity and the yield from initial development stage of mask making operations. As an example, defect density reduction is one of the biggest challenges for mask supplier in development stage to meet the yield target satisfying the mask cost and mask turn-around-time (TAT) requirement. Historically, masks were considered to be defect free but at these advanced process nodes, that assumption no longer

  3. Virosomes for antigen and DNA delivery

    NARCIS (Netherlands)

    Daemen, T; de Mare, A; Bungener, L; de Jonge, J; Huckriede, A; Wilschut, J

    2005-01-01

    Specific targeting and delivery as well as the display of antigens on the surface of professional antigen-presenting cells (APCs) are key issues in the design and development of new-generation vaccines aimed at the induction of both humoral and cell-mediated immunity. Prophylactic vaccination

  4. Radioimmunoassay for a human prostate specific antigen

    International Nuclear Information System (INIS)

    Machida, T.; Miki, M.; Ohishi, Y.; Kido, A.; Morikawa, J.; Ogawa, Y.

    1983-01-01

    As a marker for prostatic cancer, a prostate-specific antigen was purified from human prostatic tissues. Double antibody radioimmunoassay utilizing immune reaction was developed on the basis of the purified prostatic antigen (PA). Measurement results have revealed that PA radioimmunoassay is much better than prostatic acid phosphatase (PAP) radioimmunoassay in the diagnosis of prostatic cancer

  5. Emotion potentiates response activation and inhibition in masked priming.

    Science.gov (United States)

    Bocanegra, Bruno R; Zeelenberg, René

    2012-01-01

    Previous studies have shown that emotion can have 2-fold effects on perception. At the object-level, emotional stimuli benefit from a stimulus-specific boost in visual attention at the relative expense of competing stimuli. At the visual feature-level, recent findings indicate that emotion may inhibit the processing of small visual details and facilitate the processing of coarse visual features. In the present study, we investigated whether emotion can boost the activation and inhibition of automatic motor responses that are generated prior to overt perception. To investigate this, we tested whether an emotional cue affects covert motor responses in a masked priming task. We used a masked priming paradigm in which participants responded to target arrows that were preceded by invisible congruent or incongruent prime arrows. In the standard paradigm, participants react faster, and commit fewer errors responding to the directionality of target arrows, when they are preceded by congruent vs. incongruent masked prime arrows (positive congruency effect, PCE). However, as prime-target SOAs increase, this effect reverses (negative congruency effect, NCE). These findings have been explained as evidence for an initial activation and a subsequent inhibition of a partial response elicited by the masked prime arrow. Our results show that the presentation of fearful face cues, compared to neutral face cues, increased the size of both the PCE and NCE, despite the fact that the primes were invisible. This is the first demonstration that emotion prepares an individual's visuomotor system for automatic activation and inhibition of motor responses in the absence of visual awareness.

  6. Photodeposited diffractive optical elements of computer generated masks

    International Nuclear Information System (INIS)

    Mirchin, N.; Peled, A.; Baal-Zedaka, I.; Margolin, R.; Zagon, M.; Lapsker, I.; Verdyan, A.; Azoulay, J.

    2005-01-01

    Diffractive optical elements (DOE) were synthesized on plastic substrates using the photodeposition (PD) technique by depositing amorphous selenium (a-Se) films with argon lasers and UV spectra light. The thin films were deposited typically onto polymethylmethacrylate (PMMA) substrates at room temperature. Scanned beam and contact mask modes were employed using computer-designed DOE lenses. Optical and electron micrographs characterize the surface details. The films were typically 200 nm thick

  7. A nanohybrid system for taste masking of sildenafil

    Science.gov (United States)

    Lee, Ji-Hee; Choi, Goeun; Oh, Yeon-Ji; Park, Je Won; Choy, Young Bin; Park, Mung Chul; Yoon, Yeo Joon; Lee, Hwa Jeong; Chang, Hee Chul; Choy, Jin-Ho

    2012-01-01

    A nanohybrid was prepared with an inorganic clay material, montmorillonite (MMT), for taste masking of sildenafil (SDN). To further improve the taste-masking efficiency and enhance the drug-release rate, we coated the nanohybrid of SDN–MMT with a basic polymer, polyvinylacetal diethylaminoacetate (AEA). Powder X-ray diffraction and Fourier transform infrared experiments showed that SDN was successfully intercalated into the interlayer space of MMT. The AEA-coated SDN–MMT nanohybrid showed drug release was much suppressed at neutral pH (release rate, 4.70 ± 0.53%), suggesting a potential for drug taste masking at the buccal cavity. We also performed in vitro drug release experiments in a simulated gastric fluid (pH = 1.2) and compared the drug-release profiles of AEA-coated SDN–MMT and Viagra®, an approved dosage form of SDN. As a result, about 90% of SDN was released from the AEA-coated SDN–MMT during the first 2 hours while almost 100% of drug was released from Viagra®. However, an in vivo experiment showed that the AEA-coated SDN–MMT exhibited higher drug exposure than Viagra®. For the AEA-coated SDN–MMT, the area under the plasma concentration– time curve from 0 hours to infinity (AUC0-∞) and maximum concentration (Cmax) were 78.8 ± 2.32 μg · hour/mL and 12.4 ± 0.673 μg/mL, respectively, both of which were larger than those obtained with Viagra® (AUC0-∞ = 69.2 ± 3.19 μg · hour/mL; Cmax = 10.5 ± 0.641 μg/mL). Therefore, we concluded that the MMT-based nanohybrid is a promising delivery system for taste masking of SDN with possibly improved drug exposure. PMID:22619517

  8. A developed unsharp masking method for images contrast enhancement

    International Nuclear Information System (INIS)

    Zaafouri, A.; Sayadi, M.; Fnaiech, F.

    2011-01-01

    In this paper, we propose a developed unsharp masking process for contrast image enhancement. The main idea here is to enhance the dark and bright area in the same way which matches the response of human visual system well. Then in order to reduce the noise effect, a mean weighted high pass filter is used for edge extraction. The proposed method gives satisfactory results for wide range of low contrast images compared with others known approaches.

  9. Masked Tityra Tityra semifasciata in Mato Grosso do Sul, Brazil

    Czech Academy of Sciences Publication Activity Database

    Godoi, M. N.; Čapek, Miroslav; Pivatto, M. A. C.; Literák, I.; Kokeš, J.

    2011-01-01

    Roč. 19, č. 3 (2011), s. 428-433 ISSN 0103-5657 Institutional research plan: CEZ:AV0Z60930519 Keywords : Tityra semifasciata * Masked Tityra * new records * Mato Grosso do Sul * South America Subject RIV: EG - Zoology Impact factor: 0.134, year: 2011 http://www.ararajuba.org.br/sbo/ararajuba/artigos/Volume193/ccount/click.php?id=19

  10. Stabilization of Transfected Cells Expressing Low-Incidence Blood Group Antigens: Novel Methods Facilitating Their Use as Reagent-Cells.

    Directory of Open Access Journals (Sweden)

    Cecilia González

    Full Text Available The identification of erythrocyte antibodies in the serum of patients rely on panels of human red blood cells (RBCs, which coexpress many antigens and are not easily available for low-incidence blood group phenotypes. These problems have been addressed by generating cell lines expressing unique blood group antigens, which may be used as an alternative to human RBCs. However, the use of cell lines implies several drawbacks, like the requirement of cell culture facilities and the high cost of cryopreservation. The application of cell stabilization methods could facilitate their use as reagent cells in clinical laboratories.We generated stably-transfected cells expressing low-incidence blood group antigens (Dia and Lua. High-expresser clones were used to assess the effect of TransFix® treatment and lyophilization as cell preservation methods. Cells were kept at 4°C and cell morphology, membrane permeability and antigenic properties were evaluated at several time-points after treatment.TransFix® addition to cell suspensions allows cell stabilization and proper antigen detection for at least 120 days, despite an increase in membrane permeability and a reduction in antigen expression levels. Lyophilized cells showed minor morphological changes and antigen expression levels were rather conserved at days 1, 15 and 120, indicating a high stability of the freeze-dried product. These stabilized cells have been proved to react specifically with human sera containing alloantibodies.Both stabilization methods allow long-term preservation of the transfected cells antigenic properties and may facilitate their distribution and use as reagent-cells expressing low-incidence antigens, overcoming the limited availability of such rare RBCs.

  11. Preferred axis of CMB parity asymmetry in the masked maps

    International Nuclear Information System (INIS)

    Cheng, Cheng; Zhao, Wen; Huang, Qing-Guo; Santos, Larissa

    2016-01-01

    Both WMAP and Planck data show a significant odd-multipole preference in the large scales of the cosmic microwave background (CMB) temperature anisotropies. If this pattern originates from cosmological effects, then it can be considered a crucial clue for a violation in the cosmological principle. By defining various direction dependent statistics in the full-sky Planck 2015 maps (see, for instance, Naselsky et al. (2012); W. Zhao (2014)), we found that the CMB parity asymmetry has a preferred direction, which is independent of the choices of the statistics. In particular, this preferred axis is strongly aligned with those in the CMB quadrupole and octopole, as well as that in the CMB kinematic dipole, which hints to their non-cosmological origin. In realistic observations, the foreground residuals are inevitable, and should be properly masked out in order to avoid possible misinterpretation of the results. In this paper, we extend our previous analyses to the masked Planck 2015 data. By defining a similar direction dependent statistic in the masked map, we find a preferred direction of the CMB parity asymmetry, in which the axis also coincides with that found in the full-sky analysis. Therefore, our conclusions on the CMB parity violation and its directional properties are confirmed.

  12. Trial manufacture of round mask for TV fluoroscopic unit

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Matsumoto, Yukio

    1977-01-01

    Demands for revision of existing medical law were described together with an introduction of TV fluoroscopic unit. Round mask, which does not always press out the bottom face of used x-ray beam from the effective primary fluorescent face of photomultiplier inspite of shifting of a spot in time of TV fluoroscopy, was manufactured for trial, and it was furnished with already established fluoroscopic stand. It is used in daily examination without any trouble. Round mask was divided into two parts, and opened upward and downward quickly by lod motor in time of photographing. Multiple iris was operated in order to fit to film size, and round mask was closed at the same time of the finishment of photographing and fluoroscopy was performed again. Item 3 of Para 2 of Art 30 of the existing medical low states that it is good not to press out, the distance between x-ray focus and fluorescent screen, and used x-ray beam from fluorescent screen. However, a regulation, which states that x-ray beam should not be pressed out from effective primary fluorescent face in x-ray fluoroscopy using photomultiplier, must be added. Improvement of the existing unit is expected, and decrease of unnecessary exposure even in small amount is proposed. (Tsunoda, M.)

  13. Phase-enhanced defect sensitivity for EUV mask inspection

    Science.gov (United States)

    Wang, Yow-Gwo; Miyakawa, Ryan; Chao, Weilun; Goldberg, Kenneth; Neureuther, Andy; Naulleau, Patrick

    2014-10-01

    In this paper, we present a complete study on mask blank and patterned mask inspection utilizing the Zernike phase contrast method. The Zernike phase contrast method provides in-focus inspection ability to study phase defects with enhanced defect sensitivity. However, the 90 degree phase shift in the pupil will significantly reduce the amplitude defect signal at focus. In order to detect both types of defects with a single scan, an optimized phase shift instead of 90 degree on the pupil plane is proposed to achieve an acceptable trade-off on their signal strengths. We can get a 70% of its maximum signal strength at focus for both amplitude and phase defects with a 47 degree phase shift. For SNR, the tradeoff between speckle noise and signal strength has to be considered. The SNR of phase and amplitude defects at focus can both reach 11 with 13 degree phase shift and 50% apodization. Moreover, the simulation results on patterned mask inspection of partially hidden phase defects with die-to-database inspection approach on the blank inspection tool show that the improvement of the Zernike phase method is more limited. A 40% enhancement of peak signal strength can be achieved with the Zernike phase contrast method when the defect is centered in the space, while the enhancement drops to less than 10% when it is beneath the line.

  14. Interaction of Object Binding Cues in Binaural Masking Pattern Experiments.

    Science.gov (United States)

    Verhey, Jesko L; Lübken, Björn; van de Par, Steven

    2016-01-01

    Object binding cues such as binaural and across-frequency modulation cues are likely to be used by the auditory system to separate sounds from different sources in complex auditory scenes. The present study investigates the interaction of these cues in a binaural masking pattern paradigm where a sinusoidal target is masked by a narrowband noise. It was hypothesised that beating between signal and masker may contribute to signal detection when signal and masker do not spectrally overlap but that this cue could not be used in combination with interaural cues. To test this hypothesis an additional sinusoidal interferer was added to the noise masker with a lower frequency than the noise whereas the target had a higher frequency than the noise. Thresholds increase when the interferer is added. This effect is largest when the spectral interferer-masker and masker-target distances are equal. The result supports the hypothesis that modulation cues contribute to signal detection in the classical masking paradigm and that these are analysed with modulation bandpass filters. A monaural model including an across-frequency modulation process is presented that account for this effect. Interestingly, the interferer also affects dichotic thresholds indicating that modulation cues also play a role in binaural processing.

  15. International Space Station (ISS) Emergency Mask (EM) Development

    Science.gov (United States)

    Toon, Katherine P.; Hahn, Jeffrey; Fowler, Michael; Young, Kevin

    2011-01-01

    The Emergency Mask (EM) is considered a secondary response emergency Personal Protective Equipment (PPE) designed to provide respiratory protection to the International Space Station (ISS) crewmembers in response to a post-fire event or ammonia leak. The EM is planned to be delivered to ISS in 2012 to replace the current air purifying respirator (APR) onboard ISS called the Ammonia Respirator (AR). The EM is a one ]size ]fits ]all model designed to fit any size crewmember, unlike the APR on ISS, and uses either two Fire Cartridges (FCs) or two Commercial Off-the-Shelf (COTS) 3M(Trademark). Ammonia Cartridges (ACs) to provide the crew with a minimum of 8 hours of respiratory protection with appropriate cartridge swap ]out. The EM is designed for a single exposure event, for either post ]fire or ammonia, and is a passive device that cannot help crewmembers who cannot breathe on their own. The EM fs primary and only seal is around the wearer fs neck to prevent a crewmember from inhaling contaminants. During the development of the ISS Emergency Mask, several design challenges were faced that focused around manufacturing a leak free mask. The description of those challenges are broadly discussed but focuses on one key design challenge area: bonding EPDM gasket material to Gore(Registered Trademark) fabric hood.

  16. Preferred axis of CMB parity asymmetry in the masked maps

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Cheng [State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Science, Beijing 100190 (China); Zhao, Wen, E-mail: wzhao7@ustc.edu.cn [CAS Key Laboratory for Researches in Galaxies and Cosmology, Department of Astronomy, University of Science and Technology of China, Chinese Academy of Sciences, Hefei, Anhui 230026 (China); Huang, Qing-Guo [State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Science, Beijing 100190 (China); Santos, Larissa [CAS Key Laboratory for Researches in Galaxies and Cosmology, Department of Astronomy, University of Science and Technology of China, Chinese Academy of Sciences, Hefei, Anhui 230026 (China)

    2016-06-10

    Both WMAP and Planck data show a significant odd-multipole preference in the large scales of the cosmic microwave background (CMB) temperature anisotropies. If this pattern originates from cosmological effects, then it can be considered a crucial clue for a violation in the cosmological principle. By defining various direction dependent statistics in the full-sky Planck 2015 maps (see, for instance, Naselsky et al. (2012); W. Zhao (2014)), we found that the CMB parity asymmetry has a preferred direction, which is independent of the choices of the statistics. In particular, this preferred axis is strongly aligned with those in the CMB quadrupole and octopole, as well as that in the CMB kinematic dipole, which hints to their non-cosmological origin. In realistic observations, the foreground residuals are inevitable, and should be properly masked out in order to avoid possible misinterpretation of the results. In this paper, we extend our previous analyses to the masked Planck 2015 data. By defining a similar direction dependent statistic in the masked map, we find a preferred direction of the CMB parity asymmetry, in which the axis also coincides with that found in the full-sky analysis. Therefore, our conclusions on the CMB parity violation and its directional properties are confirmed.

  17. Effects of temporal integration on the shape of visual backward masking functions.

    Science.gov (United States)

    Francis, Gregory; Cho, Yang Seok

    2008-10-01

    Many studies of cognition and perception use a visual mask to explore the dynamics of information processing of a target. Especially important in these applications is the time between the target and mask stimuli. A plot of some measure of target visibility against stimulus onset asynchrony is called a masking function, which can sometimes be monotonic increasing but other times is U-shaped. Theories of backward masking have long hypothesized that temporal integration of the target and mask influences properties of masking but have not connected the influence of integration with the shape of the masking function. With two experiments that vary the spatial properties of the target and mask, the authors provide evidence that temporal integration of the stimuli plays a critical role in determining the shape of the masking function. The resulting data both challenge current theories of backward masking and indicate what changes to the theories are needed to account for the new data. The authors further discuss the implication of the findings for uses of backward masking to explore other aspects of cognition.

  18. Model-based MPC enables curvilinear ILT using either VSB or multi-beam mask writers

    Science.gov (United States)

    Pang, Linyong; Takatsukasa, Yutetsu; Hara, Daisuke; Pomerantsev, Michael; Su, Bo; Fujimura, Aki

    2017-07-01

    Inverse Lithography Technology (ILT) is becoming the choice for Optical Proximity Correction (OPC) of advanced technology nodes in IC design and production. Multi-beam mask writers promise significant mask writing time reduction for complex ILT style masks. Before multi-beam mask writers become the main stream working tools in mask production, VSB writers will continue to be the tool of choice to write both curvilinear ILT and Manhattanized ILT masks. To enable VSB mask writers for complex ILT style masks, model-based mask process correction (MB-MPC) is required to do the following: 1). Make reasonable corrections for complex edges for those features that exhibit relatively large deviations from both curvilinear ILT and Manhattanized ILT designs. 2). Control and manage both Edge Placement Errors (EPE) and shot count. 3. Assist in easing the migration to future multi-beam mask writer and serve as an effective backup solution during the transition. In this paper, a solution meeting all those requirements, MB-MPC with GPU acceleration, will be presented. One model calibration per process allows accurate correction regardless of the target mask writer.

  19. Professional and home-made face masks reduce exposure to respiratory infections among the general population.

    Science.gov (United States)

    van der Sande, Marianne; Teunis, Peter; Sabel, Rob

    2008-07-09

    Governments are preparing for a potential influenza pandemic. Therefore they need data to assess the possible impact of interventions. Face-masks worn by the general population could be an accessible and affordable intervention, if effective when worn under routine circumstances. We assessed transmission reduction potential provided by personal respirators, surgical masks and home-made masks when worn during a variety of activities by healthy volunteers and a simulated patient. All types of masks reduced aerosol exposure, relatively stable over time, unaffected by duration of wear or type of activity, but with a high degree of individual variation. Personal respirators were more efficient than surgical masks, which were more efficient than home-made masks. Regardless of mask type, children were less well protected. Outward protection (mask wearing by a mechanical head) was less effective than inward protection (mask wearing by healthy volunteers). Any type of general mask use is likely to decrease viral exposure and infection risk on a population level, in spite of imperfect fit and imperfect adherence, personal respirators providing most protection. Masks worn by patients may not offer as great a degree of protection against aerosol transmission.

  20. Inter- and intra-observer reliability of masking in plantar pressure measurement analysis.

    Science.gov (United States)

    Deschamps, K; Birch, I; Mc Innes, J; Desloovere, K; Matricali, G A

    2009-10-01

    Plantar pressure measurement is an important tool in gait analysis. Manual placement of small masks (masking) is increasingly used to calculate plantar pressure characteristics. Little is known concerning the reliability of manual masking. The aim of this study was to determine the reliability of masking on 2D plantar pressure footprints, in a population with forefoot deformity (i.e. hallux valgus). Using a random repeated-measure design, four observers identified the third metatarsal head on a peak-pressure barefoot footprint, using a small mask. Subsequently, the location of all five metatarsal heads was identified, using the same size of masks and the same protocol. The 2D positional variation of the masks and the peak pressure (PP) and pressure time integral (PTI) values of each mask were calculated. For single-masking the lowest inter-observer reliability was found for the distal-proximal direction, causing a clear, adverse impact on the reliability of the pressure characteristics (PP and PTI). In the medial-lateral direction the inter-observer reliability could be scored as high. Intra-observer reliability was better and could be scored as high or good for both directions, with a correlated improved reliability of the pressure characteristics. Reliability of multi-masking showed a similar pattern, but overall values tended to be lower. Therefore, small sized masking in order to define pressure characteristics in the forefoot should be done with care.

  1. Mask pressure effects on the nasal bridge during short-term noninvasive ventilation

    Science.gov (United States)

    Brill, Anne-Kathrin; Pickersgill, Rachel; Moghal, Mohammad; Morrell, Mary J.; Simonds, Anita K.

    2018-01-01

    The aim of this study was to assess the influence of different masks, ventilator settings and body positions on the pressure exerted on the nasal bridge by the mask and subjective comfort during noninvasive ventilation (NIV). We measured the pressure over the nasal bridge in 20 healthy participants receiving NIV via four different NIV masks (three oronasal masks, one nasal mask) at three different ventilator settings and in the seated or supine position. Objective pressure measurements were obtained with an I-Scan pressure-mapping system. Subjective comfort of the mask fit was assessed with a visual analogue scale. The masks exerted mean pressures between 47.6±29 mmHg and 91.9±42.4 mmHg on the nasal bridge. In the supine position, the pressure was lower in all masks (57.1±31.9 mmHg supine, 63.9±37.3 mmHg seated; pmasks, a change of inspiratory positive airway pressure (IPAP) did not influence the objective pressure over the nasal bridge. Subjective discomfort was associated with higher IPAP and positively correlated with the pressure on the skin. Objective measurement of pressure on the skin during mask fitting might be helpful for mask selection. Mask fitting in the supine position should be considered in the clinical routine. PMID:29637077

  2. The efficacy of three different mask styles on a PAP titration night.

    Science.gov (United States)

    Ebben, Matthew R; Oyegbile, Temitayo; Pollak, Charles P

    2012-06-01

    This study compared the efficacy of three different masks, nasal pillows, nasal masks and full face (oronasal) masks, during a single night of titration with continuous positive airway pressure (CPAP). Fifty five subjects that included men (n=33) and women (n=22) were randomly assigned to one of three masks and underwent a routine titration with incremental CPAP applied through the different masks. CPAP applied through the nasal pillows and nasal mask was equally effective in treating mild, moderate, and severe sleep apnea. However, CPAP applied through the oronasal mask required a significantly higher pressure compared to nasal masks to treat moderately severe (2.8 cm of H(2)O ± 2.1 SD) and severe (6.0 cm of H(2)O ± 3.2 SD) obstructive sleep apnea. CPAP applied with either nasal mask was effective in treating mild, moderate, and severe sleep apnea. The oronasal mask required significantly higher pressures in subjects with moderate to severe disease. Therefore, when changing from a nasal to an oronasal mask, a repeat titration is required to ensure effective treatment of sleep apnea, especially in patients with moderate to severe disease. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Barriers to mask wearing for influenza-like illnesses among urban Hispanic households.

    Science.gov (United States)

    Ferng, Yu-hui; Wong-McLoughlin, Jennifer; Barrett, Angela; Currie, Leanne; Larson, Elaine

    2011-01-01

    To identify barriers to mask wearing and to examine the factors associated with the willingness to wear masks among households. We used data sources from a study assessing the impact of 3 nonpharmaceutical interventions on the rates of influenza: exit interviews; home visits with a subset of the mask group; and a focus group. Risk perception score, univariate analysis, and logistic regression were conducted to identify the characteristics and predictors of mask use. Thematic barriers to mask wearing were identified from qualitative data obtained at home visits and focus group. Respondents from the mask group, when compared with the nonmask group, demonstrated higher risk perception scores concerning influenza (maximum score: 60, means: 37.6 and 30.2, pmask wearing (maximum score: 10, means: 7.8 and 7.3, p=.043). There was no significant association between demographic, attitudinal, or knowledge variables and adherence to wearing masks. Thematic barriers were identified such as social acceptability of mask use, comfort and fit, and perception of the risk/need for masks. Face masks may not be an effective intervention for seasonal or pandemic influenza unless the risk perception of influenza is high. Dissemination of culturally appropriate mask use information by health authorities and providers must be emphasized when educating the public. © 2010 Wiley Periodicals, Inc.

  4. A further test of the linearity of temporal summation in forward masking.

    Science.gov (United States)

    Plack, Christopher J; Carcagno, Samuele; Oxenham, Andrew J

    2007-10-01

    An experiment tested the hypothesis that the masking effects of two nonoverlapping forward maskers are summed linearly over time. First, the levels of individual noise maskers required to mask a brief 4-kHz signal presented at 10-, 20-, 30-, or 40-dB sensation level (SL) were found. The hypothesis predicts that a combination of the first masker presented at the level required to mask the 10-dB SL signal and the second masker presented at the level required to mask the 20-dB SL signal, should produce the same amount of masking as the converse situation (i.e., the first masker presented at the level required to mask the 20-dB SL signal and the second masker presented at the level required to mask the 10-dB SL signal), and similarly for the 30- and 40-dB SL signals. The results were consistent with the predictions.

  5. Design criteria for small coded aperture masks in gamma-ray astronomy

    International Nuclear Information System (INIS)

    Sembay, S.; Gehrels, N.

    1990-01-01

    Most theoretical work on coded aperture masks in X-ray and low-energy γ-ray astronomy has concentrated on masks with large numbers of elements. For γ-ray spectrometers in the MeV range, the detector plane usually has only a few discrete elements, so that masks with small numbers of elements are called for. For this case it is feasible to analyse by computer all the possible mask patterns of given dimension to find the ones that best satisfy the desired performance criteria. In this paper we develop a particular set of performance criteria for comparing the flux sensitivities, source positioning accuracies and transparencies of different mask patterns. We then present the results of such a computer analysis for masks up to dimension 5x5 unit cell and conclude that there is a great deal of flexibility in one's choice of mask pattern for each dimension. (orig.)

  6. A novel micromachined shadow mask system with self-alignment and gap control capability

    International Nuclear Information System (INIS)

    Hong, Jung Moo; Zou Jun

    2008-01-01

    We present a novel micromachined shadow mask system, which is capable of accurate self-alignment and mask-substrate gap control. The shadow mask system consists of a silicon shadow mask and a silicon carrier wafer with pyramidal cavities fabricated with bulk micromachining. Self-alignment and gap control of the shadow mask and the fabrication substrate can readily be achieved by using matching pairs of pyramidal cavities and steel spheres placed between. The layer-to-layer alignment accuracy of the new shadow mask system has been experimentally characterized and verified using both optical and atomic force microscopic measurements. As an application of this new shadow mask system, an organic thin-film transistor (OTFT) using pentacene as the semiconductor layer has been successfully fabricated and tested

  7. Evaluation of the protection factor of half-masks with respirator fitting test apparatus

    International Nuclear Information System (INIS)

    Murata, M.; Ikezawa, Y.; Yoshida, Y.; Matsui, H.; Kokubu, M.

    1980-01-01

    A respirator fitting test apparatus has been developed to select half-masks of high performance and to estimate their protective ability. With the apparatus, the facepiece leakage was measured for six different half-masks worn by 40 volunteer subjects, under simulated working conditions of normal breathing, smiling, moving head, and talking. A cloud of submicron sodium chloride particles was fed into a test hood in which the subject wore a mask. The air sampled from inside the mask with a miniature pump was assessed by a flame photometer. It is hown that the protection factor (ratio of the concentration of test cloud outside the mask to that inside) for each mask varies widely with the subject and the working conditions, and that the protection factors roughly fit a lognormal distribution. The values characterizing the distributions of respective masks are given. (H.K.)

  8. Mechanically and electrically robust metal-mask design for organic CMOS circuits

    Science.gov (United States)

    Shintani, Michihiro; Qin, Zhaoxing; Kuribara, Kazunori; Ogasahara, Yasuhiro; Hiromoto, Masayuki; Sato, Takashi

    2018-04-01

    The design of metal masks for fabricating organic CMOS circuits requires the consideration of not only the electrical property of the circuits, but also the mechanical strength of the masks. In this paper, we propose a new design flow for metal masks that realizes coanalysis of the mechanical and electrical properties and enables design exploration considering the trade-off between the two properties. As a case study, we apply a “stitching technique” to the mask design of a ring oscillator and explore the best design. With this technique, mask patterns are divided into separate parts using multiple mask layers to improve the mechanical strength at the cost of high resistance of the vias. By a numerical experiment, the design trade-off of the stitching technique is quantitatively analyzed, and it is demonstrated that the proposed flow is useful for the exploration of the designs of metal masks.

  9. Studies on antigenic cross-reactivity of Trichuris ovis with host mucosal antigens in goat

    Directory of Open Access Journals (Sweden)

    Gautam Patra

    2015-12-01

    Full Text Available Objective: To ascertain whether immunodominant antigens of Trichuris ovis might share and cross react with host molecule. Methods: Two crude protein preparations from anterior and posterior parts of Trichuris ovis were characterized along with host mucosal antigen by double immunodiffusion, sodium dodecyl sulfate-polyacrylamide gel electrophoresis and western blotting technique. Conventional scanning electron microscopy was performed as per standard procedure. Results: Sharp and distinct bands of three antigens have been found in double immunodiffusion using hyperimmune serum raised in rabbit indicating the presence of specific antibody against each antigen. All three antigens have shown major and minor bands with molecular weight ranging from 15 to 110 kDa during sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Conclusions: The antigenic cross-reactivity was thought to result from shared antigens. The existence of paracloacal papillae found in the anterior part of the male was not a unique feature for species differentiation.

  10. Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask

    Science.gov (United States)

    Kelly, Mark; Pettit, Donald

    2003-01-01

    A device that generates an alarm when the partial pressure of oxygen decreases to less than a preset level has been developed to help prevent hypoxia in a pilot or other crewmember of a military or other high-performance aircraft. Loss of oxygen partial pressure can be caused by poor fit of the mask or failure of a hose or other component of an oxygen distribution system. The deleterious physical and mental effects of hypoxia cause the loss of a military aircraft and crew every few years. The device is installed in the crewmember s oxygen mask and is powered via communication wiring already present in all such oxygen masks. The device (see figure) includes an electrochemical sensor, the output potential of which is proportional to the partial pressure of oxygen. The output of the sensor is amplified and fed to the input of a comparator circuit. A reference potential that corresponds to the amplified sensor output at the alarm oxygen-partial-pressure level is fed to the second input of the comparator. When the sensed partial pressure of oxygen falls below the minimum acceptable level, the output of the comparator goes from the low state (a few millivolts) to the high state (near the supply potential, which is typically 6.8 V for microphone power). The switching of the comparator output to the high state triggers a tactile alarm in the form of a vibration in the mask, generated by a small 1.3-Vdc pager motor spinning an eccentric mass at a rate between 8,000 and 10,000 rpm. The sensation of the mask vibrating against the crewmember s nose is very effective at alerting the crewmember, who may already be groggy from hypoxia and is immersed in an environment that is saturated with visual cues and sounds. Indeed, the sensation is one of rudeness, but such rudeness could be what is needed to stimulate the crewmember to take corrective action in a life-threatening situation.

  11. Optimized qualification protocol on particle cleanliness for EUV mask infrastructure

    Science.gov (United States)

    van der Donck, J. C. J.; Stortelder, J. K.; Derksen, G. B.

    2011-11-01

    With the market introduction of the NXE:3100, Extreme Ultra Violet Lithography (EUVL) enters a new stage. Now infrastructure in the wafer fabs must be prepared for new processes and new materials. Especially the infrastructure for masks poses a challenge. Because of the absence of a pellicle reticle front sides are exceptionally vulnerable to particles. It was also shown that particles on the backside of a reticle may cause tool down time. These effects set extreme requirements to the cleanliness level of the fab infrastructure for EUV masks. The cost of EUV masks justifies the use of equipment that is qualified on particle cleanliness. Until now equipment qualification on particle cleanliness have not been carried out with statistically based qualification procedures. Since we are dealing with extreme clean equipment the number of observed particles is expected to be very low. These particle levels can only be measured by repetitively cycling a mask substrate in the equipment. Recent work in the EUV AD-tool presents data on added particles during load/unload cycles, reported as number of Particles per Reticle Pass (PRP). In the interpretation of the data, variation by deposition statistics is not taken into account. In measurements with low numbers of added particles the standard deviation in PRP number can be large. An additional issue is that particles which are added in the routing outside the equipment may have a large impact on the testing result. The number mismatch between a single handling step outside the tool and the multiple cycling in the equipment makes accuracy of measurements rather complex. The low number of expected particles, the large variation in results and the combined effect of added particles inside and outside the equipment justifies putting good effort in making a test plan. Without a proper statistical background, tests may not be suitable for proving that equipment qualifies for the limiting cleanliness levels. Other risks are that a

  12. The value of serum Hepatitis B surface antigen quantification in ...

    African Journals Online (AJOL)

    The value of serum Hepatitis B surface antigen quantification in determining viralactivity in chronic Hepatitis B virus infection. ... ofCHB andalso higher in hepatitis e antigen positive patients compared to hepatitis e antigen negative patients.

  13. Challenges of anamorphic high-NA lithography and mask making

    Science.gov (United States)

    Hsu, Stephen D.; Liu, Jingjing

    2017-06-01

    Chip makers are actively working on the adoption of 0.33 numerical aperture (NA) EUV scanners for the 7-nm and 5-nm nodes (B. Turko, S. L. Carson, A. Lio, T. Liang, M. Phillips, et al., in `Proc. SPIE9776, Extreme Ultraviolet (EUV) Lithography VII', vol. 977602 (2016) doi: 10.1117/12.2225014; A. Lio, in `Proc. SPIE9776, Extreme Ultraviolet (EUV) Lithography VII', vol. 97760V (2016) doi: 10.1117/12.2225017). In the meantime, leading foundries and integrated device manufacturers are starting to investigate patterning options beyond the 5-nm node (O. Wood, S. Raghunathan, P. Mangat, V. Philipsen, V. Luong, et al., in `Proc. SPIE. 9422, Extreme Ultraviolet (EUV) Lithography VI', vol. 94220I (2015) doi: 10.1117/12.2085022). To minimize the cost and process complexity of multiple patterning beyond the 5-nm node, EUV high-NA single-exposure patterning is a preferred method over EUV double patterning (O. Wood, S. Raghunathan, P. Mangat, V. Philipsen, V. Luong, et al., in `Proc. SPIE. 9422, Extreme Ultraviolet (EUV) Lithography VI', vol. 94220I (2015) doi: 10.1117/12.2085022; J. van Schoot, K. van Ingen Schenau, G. Bottiglieri, K. Troost, J. Zimmerman, et al., `Proc. SPIE. 9776, Extreme Ultraviolet (EUV) Lithography VII', vol. 97761I (2016) doi: 10.1117/12.2220150). The EUV high-NA scanner equipped with a projection lens of 0.55 NA is designed to support resolutions below 10 nm. The high-NA system is beneficial for enhancing resolution, minimizing mask proximity correction bias, improving normalized image log slope (NILS), and controlling CD uniformity (CDU). However, increasing NA from 0.33 to 0.55 reduces the depth of focus (DOF) significantly. Therefore, the source mask optimization (SMO) with sub-resolution assist features (SRAFs) are needed to increase DOF to meet the demanding full chip process control requirements (S. Hsu, R. Howell, J. Jia, H.-Y. Liu, K. Gronlund, et al., EUV `Proc. SPIE9048, Extreme Ultraviolet (EUV) Lithography VI', (2015) doi: 10

  14. Unmasking the effects of masking on performance: The potential of multiple-voice masking in the office environment.

    Science.gov (United States)

    Keus van de Poll, Marijke; Carlsson, Johannes; Marsh, John E; Ljung, Robert; Odelius, Johan; Schlittmeier, Sabine J; Sundin, Gunilla; Sörqvist, Patrik

    2015-08-01

    Broadband noise is often used as a masking sound to combat the negative consequences of background speech on performance in open-plan offices. As office workers generally dislike broadband noise, it is important to find alternatives that are more appreciated while being at least not less effective. The purpose of experiment 1 was to compare broadband noise with two alternatives-multiple voices and water waves-in the context of a serial short-term memory task. A single voice impaired memory in comparison with silence, but when the single voice was masked with multiple voices, performance was on level with silence. Experiment 2 explored the benefits of multiple-voice masking in more detail (by comparing one voice, three voices, five voices, and seven voices) in the context of word processed writing (arguably a more office-relevant task). Performance (i.e., writing fluency) increased linearly from worst performance in the one-voice condition to best performance in the seven-voice condition. Psychological mechanisms underpinning these effects are discussed.

  15. Complete separation of the tube from the mask of a reusable classic laryngeal mask airway: a case report

    Directory of Open Access Journals (Sweden)

    Ali Shahriari

    2007-06-01

    Full Text Available

    The laryngeal mask airway (LMA is an important addition to the anesthetist's equipments. However, its usage may involve some complications. We have encountered an unusual and potentially serious complication using this equipment. A 45-year old man underwent cataract surgery under general anesthesia. After the induction of anesthesia, a size 4 of the reusable classic LMA was inserted without any difficulties and the cuff was inflated. After a little manipulation, the proximal tube of the LMA was separated from the distal part, leaving the distal mask inside the pharynx. The exit of the remaining portion of the LMA was very difficult and made the ventilation of the patient impossible. The patient’s oxygen saturation decreased to 40%. The remaining portion of the LMA was removed by a great clamp and with an extreme effort. Then, an endotracheal tube was inserted and the patient was ventilated with 100% oxygen. After 6 hours, the patient was discharged with no apparent complications. The autoclave was used several times for the sterilization of the LMA.

    KEY WORDS: Laryngeal mask airway, autoclave.

  16. Overcoming Blockages to Collective Innovation in Digital Infrastructures

    DEFF Research Database (Denmark)

    Rukanova, Boriana; Reuver, Mark; Henningsson, Stefan

    2017-01-01

    Decentralized digital technologies increasingly enable multiple organizations to co-create digital infrastructures. However, collective innovation processes often come to a stand-still because of conflicting interests and business models. While existing research suggests various factors that block...... collective innovation processes, there is still little understanding of how organizations can overcome these blockages. In this paper, we identify patterns that explain how organizations overcome blockages of collective innovation processes for digital infrastructures. We follow a processual approach...... and develop a conceptual framework based on collective action theory. We evaluate the framework through a longitudinal case study on mobile payment infrastructure development. We find various reconfiguration processes that organizations use to overcome blockages of collective innovation. Theoretically...

  17. Beyond a Mask and Against the Bottleneck: Retroactive Dual-Task Interference During Working Memory Consolidation of a Masked Visual Target

    NARCIS (Netherlands)

    Nieuwenstein, Mark; Wyble, Brad

    While studies on visual memory commonly assume that the consolidation of a visual stimulus into working memory is interrupted by a trailing mask, studies on dual-task interference suggest that the consolidation of a stimulus can continue for several hundred milliseconds after a mask. As a result,

  18. AutoMOPS--B2B and B2C in mask making: mask manufacturing performance and customer satisfaction improvement through better information flow management

    Science.gov (United States)

    de Ridder, Luc; Filies, Olaf; Rodriguez, Ben; Kuijken, Aart

    2001-04-01

    Through application of modern supply chain concepts in combination with state-of-the-art information technology, mask manufacturing performance and customer satisfaction can be improved radically. The AutoMOPS solution emphasizes on the elimination of the order verification through paperless, electronically linked information sharing/exchange between chip design, mask production and prototype production stages.

  19. 42 CFR 84.1135 - Half-mask facepieces, full facepieces, hoods, helmets, and mouthpieces; fit; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Half-mask facepieces, full facepieces, hoods... Air-Purifying High Efficiency Respirators and Combination Gas Masks § 84.1135 Half-mask facepieces, full facepieces, hoods, helmets, and mouthpieces; fit; minimum requirements. (a) Half-mask facepieces...

  20. Leukemia-associated antigens in man.

    Science.gov (United States)

    Brown, G; Capellaro, D; Greaves, M

    1975-12-01

    Rabbit antisera raised against acute lymphoblastic leukemia (ALL) cells were used to distinguish ALL from other leukemias, to identify rare leukemia cells in the bone marrow of patients in remission, and to define human leukemia-associated antigens. Antibody binding was studied with the use of immunofluorescence reagents and the analytic capacity of the Fluorescence Activated Cell Sorter-1 (FACS-1). The results indicated that most non-T-cell ALL have three leukemia-associated antigens on their surface which are absent from normal lymphoid cells: 1) an antigen shared with myelocytes, myeloblastic leukemia cells, and fetal liver (hematopoietic) cells; 2) an antigen shared with a subset of intermediate normoblasts in normal bone marrow and fetal liver; and 3) an antigen found thus far only on non-T-cell ALL and in some acute undifferentiated leukemias, which we therefore regard as a strong candidate for a leukemia-specific antigen. These antigens are absent from a subgroup of ALL patients in which the lymphoblasta express T-cell surface markers. Preliminary studies on the bone marrow samples of patients in remission indicated that rare leukemia cells were present in some samples. The implications of these findings with respect to the heterogeneity and cell origin(s) of ALL, its diagnosis, and its potential monitoring during treatment were discussed.