  1. Experimental results showing the internal three-component velocity field and outlet temperature contours for a model gas turbine combustor

    CSIR Research Space (South Africa)

    Meyers, BC

    2011-09-01

    Full Text Available by the American Institute of Aeronautics and Astronautics Inc. All rights reserved ISABE-2011-1129 EXPERIMENTAL RESULTS SHOWING THE INTERNAL THREE-COMPONENT VELOCITY FIELD AND OUTLET TEMPERATURE CONTOURS FOR A MODEL GAS TURBINE COMBUSTOR BC Meyers*, GC... identifier c Position identifier F Fuel i Index L (Combustor) Liner OP Orifice plate Introduction There are often inconsistencies when comparing experimental and Computational Fluid Dynamics (CFD) simulations for gas turbine combustors [1...

  2. Numerical analysis of temperature fluctuation in core outlet region of China experimental fast reactor

    International Nuclear Information System (INIS)

    Zhu Huanjun; Xu Yijun

    2014-01-01

    The temperature fluctuation in core outlet region of China Experimental Fast Reactor (CEFR) was numerically simulated by the CFD software Star CCM+. With the core outlet temperatures, flows etc. under rated conditions given as boundary conditions, a 1/4 region model of the reactor core outlet region was established and calculated using LES method for this problem. The analysis results show that while CEFR operates under rated conditions, the temperature fluctuation in lower part of core outlet region is mainly concentrated in area over the edge components (steel components, control rod assembly), and one in upper part is remarkable in area above all the components. The largest fluctuation amplitude is 19 K and the remarkable frequency is below 5 Hz, and it belongs to typically low frequency fluctuation. The conclusion is useful for further experimental work. (authors)

  3. Approach to the HTGR core outlet temperature measurements in the United States

    International Nuclear Information System (INIS)

    Franklin, R.; Rodriguez, C.

    1982-06-01

    The High Temperature Gas-Cooled Reactor (HTGR) constructed at Fort St. Vrain Colorado (330 MWe) used Geminol thermocouples to measure the primary coolant temperature at the core outlet. The primary coolant (helium) is heated by the graphite core to temperatures in the range of 700 deg. to 750 deg. C. The combination of the high temperature, high flow rate and radiation at the core outlet area makes it difficult to obtain accurate temperature measurements. The Geminol thermocouples installed in the Fort St. Vrain reactor have provided accurate data for several years of power operation without any failures. The indicated temperature of the core outlet thermocouples agrees with a ''traversing'' thermocouple measurement to within +-2 deg. C. The Geminol thermocouple wire was provided by the Driver-Harris Company and is similar to the chromel versus alumel thermocouple. Geminol wire is no longer distributed and on future designs, chromel versus alumel wire will be used. The next large HTGR design, which is being performed with funding support from the United States Department of Energy, will incorporate replaceable thermocouples. The thermocouples used in the Fort St. Vrain reactor were permanently installed and large in diameter (6.35 mm) to insure good reliability. The replaceable thermocouples to be used in the next large reactor will be smaller in diameter (3.18 mm). These replaceable thermocouples will be inserted into the core outlet area through long curved guide tubes that are permanently installed. These guide tubes are as long as 18 meters and must be curved to reach the core outlet regions. Tests were conducted to prove that the thermocouples could be inserted and removed through the long curved guide tubes. (author)

  4. Effect of spacer grid mixing vanes on coolant outlet temperature distribution

    Energy Technology Data Exchange (ETDEWEB)

    Raemae, Tommi; Lahtinen, Tuukka; Brandt, Tellervo; Toppila, Timo [Fortum Power and Heat, Fortum (Finland). Nuclear Competence Center

    2012-08-15

    In Loviisa VVER-440-type NPP the coolant outlet temperature of the hot subchannel is constantly monitored during the operation. According to the authority requirement the maximum subchannel outlet temperature must not exceed the saturation temperature. Coolant temperature distribution inside the fuel assembly is affected by the efficiency of the coolant mixing. In order to enhance the coolant mixing the fuel manufacturer is introducing the additional mixing vanes on the fuel bundle spacer grids. In the paper the effect of the different mixing vane modifications is studied with computational fluid dynamics (CFD) simulation. Goal of the modelling is to find vane modifications with which sufficient mixing is reached with acceptable increase in the spacer grid pressure loss. The results of the studies are discussed in the paper. (orig.)

  5. Temperature measurements at the LMFBR core outlet

    International Nuclear Information System (INIS)

    Argous, J.P.; Berger, R.; Casejuane, R.; Fournier, C.; Girard, J.P.

    1980-04-01

    Over the last few years the temperature sensors used to measure the subassembly outlet temperature in French designed LMFBRs have been modified, basically in an effort to reduce the dispersion of the chromel-alumel thermocouple time constant, and to extend the frequency spectrum of the measurement signals by adding a steel electrode to from a stainless steel-sodium thermocouple. The result of this evolution is the temperature probe immersed in sodium which will be used in the SUPER PHENIX reactor. This paper describes the tests already completed or in progress on this probe. It also presents measurement data on the two basic probe parameters: the thermoelectric power of the stainless steel-sodium thermocouple and the time constant of the chromel-alumel thermocouple

  6. Interferometric investigation of turbulently fluctuating temperature in an LMFBR outlet plenum geometry

    International Nuclear Information System (INIS)

    Bennett, R.G.; Golay, M.W.

    1975-01-01

    A novel optical technique is described for the measurement of turbulently fluctuating temperature in a transparent fluid flow. The technique employs a Mach-Zehnder interferometer of extremely short field and a simple photoconductive diode detector. The system produces a nearly linear D.C. electrical analog of the turbulent temperature fluctuations in a small, 1 mm 3 volume. The frequency response extends well above 2500 Hz, and can be improved by the choice of a more sophisticated photodetector. The turbulent sodium mixing in the ANL 1 1 / 15 -scale FFTF outlet plenum is investigated with a scale model outlet mixing plenum, using flows of air. The scale design represents a cross section of the ANL outlet plenum, so that the average recirculating flow inside the test cell is two dimensional. The range of the instrument is 120 0 F above the ambient air temperature. The accuracy is generally +-5 0 F, with most of the error due to noise originating from building vibrations and room noise. The power spectral density of the fluctuating temperature has been observed experimentally at six different stations in the flow. A strong 300 Hz component is generated in the inlet region, which decays as the flow progresses along streamlines. The effect of the inlet Reynolds number and the temperature difference between the inlet flows on the power spectral density has also been investigated. Traces of the actual fluctuating temperature are included for the six stations

  7. Consideration of hot channel factors in design for providing operating margins on coolant channel outlet temperature

    International Nuclear Information System (INIS)

    Sharma, V.K.; Surendar, C.; Bapat, C.N.

    1994-01-01

    The Indian Pressurized Heavy Water Reactors (IPHWR) are horizontal pressure tube reactors using natural uranium oxide fuel in the form of short (495 mm) clusters. The fuel clusters in the Zr-Nb pressure tubes are cooled by high pressure, high temperature and subcooled circulating heavy water. Coolant flow distribution to individual channels is designed to match the power distribution so as to obtain uniform coolant outlet temperature. However, during operation, the coolant outlet temperature in individual channels deviate from their nominal value due to: tolerances in process design; effects of grid frequency on the pump speed; deviation in channel powers from the nominal values due to on-power fuelling and movement of reactivity devices, and so on. Thus an operating margin, between the highest permissible and nominal coolant outlet temperatures, is required taking into account various hot channel factors that contribute to higher coolant outlet temperatures. The paper discusses the methodology adopted to assess various hot channel factors which would provide optimum operating margins while ensuring sub-cooling. (author)

  8. Computer supervision of the core outlet sodium temperatures of FBTR

    International Nuclear Information System (INIS)

    Boopathy, C.

    1976-01-01

    Safety monitoring of the fast breeder test reactor at Kalpakkam (India) is achieved by a CDPS-on-line dual computer system which is dedicated to plant supervision. The on-line subsystem scans and supervises all the 170 core thermocouple signals every second. Organisation of the reactor core instruments, supervision of mean sodium outlet temperature and mean temperature drop across the core, detection of plugging of a fuel assembly are explained. (A.K.)

  9. Noise and DC balanced outlet temperature signals for monitoring coolant flow in LMFBR fuel elements

    International Nuclear Information System (INIS)

    Edelmann, M.

    1977-01-01

    Local cooling disturbances in LMFBR fuel elements may have serious safety implications for the whole reactor core. They have to be detected reliably in an early stage of their formation therefore. This can be accomplished in principle by individual monitoring of the coolant flow rate or the coolant outlet temperature of the sub-assemblies with high precision. In this paper a method is proposed to increase the sensitivity of outlet temperature signals to cooling disturbances. Using balanced temperature signals provides a means for eliminating the normal variations from the original signals which limit the sensitivity and speed of response to cooling disturbances. It is shown that a balanced signal can be derived easily from the original temperature signal by subtracting an inlet temperature and a neutron detector signal with appropriate time shift. The method was tested with tape-recorded noise signals of the KNK I reactor at Karlsruhe. The experimental results confirm the theoretical predictions. A significant reduction of the uncertainty of measured outlet temperatures was achieved. This enables very sensitive and fast response monitoring of coolant flow. Furthermore, it was found that minimizing the variance of the balanced signal offers the possibility for a rough determination of the heat transfer coefficient of the fuel rods during normal reactor operation at power. (author)

  10. Influence of the outlet air temperature on the thermohydraulic behaviour of air coolers

    Directory of Open Access Journals (Sweden)

    Đorđević Emila M.

    2003-01-01

    Full Text Available The determination of the optimal process conditions for the operation of air coolers demands a detailed analysis of their thermohydraulic behaviour on the one hand, and the estimation of the operating costs, on the other. One of the main parameters of the thermohydraulic behaviour of this type of equipment, is the outlet air temperature. The influence of the outlet air temperature on the performance of air coolers (heat transfer coefficient overall heat transfer coefficient, required surface area for heat transfer air-side pressure drop, fan power consumption and sound pressure level was investigated in this study. All the computations, using AirCooler software [1], were applied to cooling of the process fluid and the condensation of a multicomponent vapour mixture on two industrial devices of known geometries.

  11. Outlet temperature measurement correction of Gd fuel assemblies at Dukovany NPP

    International Nuclear Information System (INIS)

    Jurickova, M.

    2008-01-01

    In year 2006 we started data processing from the Dukovany NPP operating history database that contained data from the old measurement system VK3 and the new Scorpio-VVER. The work has been done in cooperation with the reactor physicists at Dukovany NPP. Obtained data from database were compared with calculated parameters from 3D diffusion macrocode Mobydick. During the data processing it was found that the Gd fuel assemblies have different time plot of measured assembly outlet temperature compared to the non-Gd fuel assemblies. Experimental studies in RRC KI found that there is insufficient coolant mixing in the region from the fuel bundle to the fuel assembly thermocouple. Due to this fact the thermocouple measure temperature is systematically higher than real temperature. There are two methods to solve this problem. The first method analyses the flow and heat transfer in the region from the fuel bundle to the fuel assembly thermocouple - this method is developed in Skoda JS. The second method statistically studies differences between the measured and calculated temperature by the Mobydick code using the operational history database. Our study is focused on the second method. Several calculation methods for the correction of measured assembly outlet temperature were developed. All correction methods were applied to the measured temperatures from the Dukovany NPP operating history database and the methods were mutually compared. In near future it is planned to compare results of our chosen correction method with modeling method, which is developing in Skoda JS and it is planned to validate both of them. Consequently, the one of these correction methods will be implemented in the modernized Scorpio-VVER for Dukovany NPP. (author)

  12. Stratification in SNR-300 outlet plenum

    International Nuclear Information System (INIS)

    Reinders, R.

    1983-01-01

    In the inner outlet plenum of the SNR-300 under steady state conditions a large toroidal vortex is expected. The main flow passes through the gap between dipplate and shield vessel to the outer annular space. Only 3% of the flow pass the 24 emergency cooling holes, situated in the shield vessel. The sodium leaves the reactor tank through the 3 symmetrically arranged outlet nozzles. For a scram flow rates and temperatures are decreased simultaneously, so it is expected, that stratification occurs in the inner outlet plenum. A measure of stratification effects is the Archimedes Number Ar, which is the relation of buoyancy forces (negative) to kinetic energy. (The Archimedes Number is nearly identical with the Richardson Number). For values Ar>1 stratification can occur. Under the assumption of stratification the code TIRE was developed, which is only applicable for the period of time after some 50 sec after scram. This code serves for long term calculations. As the equations are very simple, it is a very fast code which gives the possibility to calculate transients for some hours real time. This code mainly has to take into account the pressure difference between inner plenum and outlet annulus caused by geodatic pressure. That force is in equilibrium with the pressure drop over the gap and holes in the shield vessel. For more detailed calculations of flow pattern and temperature distribution the code MIX and INKO 2T are applied. MIX was developed and validated at ANL, INKO 2T is a development of INTERATOM. INKO 2T is under validation. Mock up experiments were carried out with water to simulate the transient behavior of the SNR-300 outlet plenum. Calculations obtained by INKO 2T for steady state and the transient are shown for the flow pattern. Results of measurements also prove that stratification begins after about 30 sec. Measurements and detailed calculations show that it is admissible to use the code TIRE for the long term calculations. Calculations for a scram

  13. Method for determining the outlet temperature of fuel assemblies unsupplied with thermometer in WWER-440 reactors

    International Nuclear Information System (INIS)

    Miko, S.; Kalya, Z.; Hamvas, I.

    1987-09-01

    The paper outlines a method for the evaluation of the outlet temperatures of fuel assemblies unsupplied with thermometer in WWER-440 reactors. The process is based on interpolation of directly measured assembly temperatures. A quantitative comparison of the errors of described algorithm to those of standard plant-computer interpolation rutine is also presented. (author)

  14. Study on partial overheat of the isolated phase busbar outlet box in Qinshan NPP phase Ⅱ

    International Nuclear Information System (INIS)

    Tang Fangxuan; Zhang Jian; Zeng Limin; Bao Yanxing; Zhang Lie; Yang Yuemin

    2013-01-01

    This paper recommended the structure of the isolated phase busbar outlet box installed in Qinshan II. The study on partial overheat of the outlet box shows that the ultimate causes are the loss of concentrated eddy current and short of cooling. So the improvement principles of 'distributing eddy current, cutting off inductive circle current and strengthening of ventilation' were determined. A new structure test outlet box was designed and manufactured, and the temperature rising experiment was carried out. Some alterations were made in the new structure outlet box, e.g. isolating materials were added between side plates of the upper outlet box, and also between the upper and lower outlet box. Two cooling blowers were added to the upper outlet box. After putting into operation, the hot-spot temperature of the new outlet box was greatly lowered down. Thus the operation environment was improved, and the operation safety ensured. It can be useful references for analyzing and dealing with similar problems. (authors)

  15. The lithium-lithium hydride process for the production of hydrogen: comparison of two concepts for 950 and 1300 deg C HTR helium outlet temperature

    International Nuclear Information System (INIS)

    Oertel, M.; Weirich, W.; Kuegler, B.; Luecke, L.; Pietsch, M.; Winkelmann, U.

    1987-01-01

    The lithium-lithium hydride process serves to generate hydrogen from water efficiently, using the high temperature heat of a nuclear reactor. Thermodynamic analyses show that hydrogen can be produced with an overall thermal efficiency of 48% at conventional HTR outlet temperatures of 950 0 C. Assuming helium heat of 1300 0 C, 56% overall thermal efficiency can be achieved. (author)

  16. A thermal analysis computer programme package for the estimation of KANUPP coolant channel flows and outlet header temperature distribution

    International Nuclear Information System (INIS)

    Siddiqui, M.S.

    1992-06-01

    COFTAN is a computer code for actual estimation of flows and temperatures in the coolant channels of a pressure tube heavy water reactor. The code is being used for Candu type reactor with coolant flowing 208 channels. The simulation model first performs the detailed calculation of flux and power distribution based on two groups diffusion theory treatment on a three dimensional mesh and then channel powers, resulting from the summation of eleven bundle powers in each of the 208 channels, are employed to make actual estimation of coolant flows using channel powers and channel outlet temperature monitored by digital computers. The code by using the design flows in individual channels and applying a correction factor based on control room monitored flows in eight selected channels, can also provide a reserve computational tool of estimating individual channel outlet temperatures, thus providing an alternate arrangements for checking Rads performance. 42 figs. (Orig./A.B.)

  17. Analysis of systematic error deviation of water temperature measurement at the fuel channel outlet of the reactor Maria

    International Nuclear Information System (INIS)

    Bykowski, W.

    2000-01-01

    The reactor Maria has two primary cooling circuits; fuel channels cooling circuit and reactor pool cooling circuit. Fuel elements are placed inside the fuel channels which are parallely linked in parallel, between the collectors. In the course of reactor operation the following measurements are performed: continuous measurement of water temperature at the fuel channels inlet, continuous measurement of water temperature at the outlet of each fuel channel and continuous measurement of water flow rate through each fuel channel. Based on those thermal-hydraulic parameters the instantaneous thermal power generated in each fuel channel is determined and by use of that value the thermal balance and the degree of fuel burnup is assessed. The work contains an analysis concerning estimate of the systematic error of temperature measurement at outlet of each fuel channel and so the erroneous assessment of thermal power extracted in each fuel channel and the burnup degree for the individual fuel element. The results of measurements of separate factors of deviations for the fuel channels are enclosed. (author)

  18. Judgement on the data for fuel assembly outlet temperatures of WWER fuel assemblies in power reactors based on measurements with experimental fuel assemblies

    International Nuclear Information System (INIS)

    Krause, F.

    1986-01-01

    In the period from 1980 to 1985, in the Rheinsberg nuclear power plant experimental fuel assemblies were used on lattices at the periphery of the core. These particular fuel assemblies dispose of an extensive in-core instrumentation with different sensors. Besides this, they are fit out with a device to systematically thottle the coolant flow. The large power gradient present at the core position of the experimental fuel assembly causes a temperature profile along the fuel assemblies which is well provable at the measuring points of the outlet temperature. Along the direction of flow this temperature profile in the coolant degrades only slowly. This effect is to be taken into account when measuring the fuel assembly outlet temperature of WWER fuel assemblies. Besides this, the results of the measurements hinted both at a γ-heating of the temperature measuring points and at tolerances in the calculation of the micro power density distribution. (author)

  19. Laboratory determination of normal operating flow rates with enlarged outlet fittings -- BDF reactors

    Energy Technology Data Exchange (ETDEWEB)

    Waters, E.D.

    1960-02-02

    Experiments have been conducted in the Hydraulics Laboratory, at the request of IPD`s Mechanical Development-A Operation, to determine the energy losses of various enlarged outlet fitting combinations. These experiments were conducted an steady state runs and allow the determination of the normal operating point (flow rate) of a reactor process channel under selected conditions of front header pressure and fuel charge. No attempt is made to make a mechanical or economic evaluation of the particular fitting combinations, although observations were noted which might bear on this evaluation. It is very important for the reader to bear in mind that changing outlet fittings will definitely affect the reactor tube power limits and outlet vater temperature limits. The size of the outlet fittings largely determines the present outlet temperature limits of the old reactors. The flow characteristics of these present fittings cause some degree of pressurization to suppress boiling on the fuel charge and also cause dual Panellit trip protection for certain flow changes and for power surges. Enlargement of the outlet fittings may actually reduce the allowable outlet coolant temperature limits. Since these effects cannot be determined on the apparatus used in these experiments, a complete discussion of this point is not included in this report. However, the seriousness of these effects should be known and carefully analyzed before a final selection of enlarged outlet fittings in made. This report will be one of a series. New reports in the series will be issued as data are obtained for other such outlet fitting combinations or for new concepts of outlet fitting assemblies such as the new nozzle being developed by C. E. Trantz for use on F-reactor stuck gunbarrel tubes.

  20. Experiment study on thermal mixing performance of HTR-PM reactor outlet

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Yangping, E-mail: zhouyp@mail.tsinghua.edu.cn [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, the Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing 100084 (China); Hao, Pengfei [School of Aerospace, Tsinghua University, Beijing 100084 (China); Li, Fu; Shi, Lei [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, the Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing 100084 (China); He, Feng [School of Aerospace, Tsinghua University, Beijing 100084 (China); Dong, Yujie; Zhang, Zuoyi [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, the Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing 100084 (China)

    2016-09-15

    A model experiment is proposed to investigate the thermal mixing performance of HTR-PM reactor outlet. The design of the test facility is introduced, which is set at a scale of 1:2.5 comparing with the design of thermal mixing structure at HTR-PM reactor outlet. The test facility using air as its flow media includes inlet pipe system, electric heaters, main mixing structure, hot gas duct, exhaust pipe system and I&C system. Experiments are conducted on the test facility and the values of thermal-fluid parameters are collected and analyzed, which include the temperature, pressure and velocity of the flow as well as the temperature of the tube wall. The analysis results show the mixing efficiency of the test facility is higher than that required by the steam generator of HTR-PM, which indicates that the thermal mixing structure of HTR-PM fulfills its design requirement.

  1. The geography of Fast Food outlets: a review.

    Science.gov (United States)

    Fraser, Lorna K; Edwards, Kimberly L; Cade, Janet; Clarke, Graham P

    2010-05-01

    The availability of food high in fat, salt and sugar through Fast Food (FF) or takeaway outlets, is implicated in the causal pathway for the obesity epidemic. This review aims to summarise this body of research and highlight areas for future work. Thirty three studies were found that had assessed the geography of these outlets. Fourteen studies showed a positive association between availability of FF outlets and increasing deprivation. Another 13 studies also included overweight or obesity data and showed conflicting results between obesity/overweight and FF outlet availability. There is some evidence that FF availability is associated with lower fruit and vegetable intake. There is potential for land use policies to have an influence on the location of new FF outlets. Further research should incorporate good quality data on FF consumption, weight and physical activity.

  2. The Geography of Fast Food Outlets: A Review

    Directory of Open Access Journals (Sweden)

    Lorna K. Fraser

    2010-05-01

    Full Text Available The availability of food high in fat, salt and sugar through Fast Food (FF or takeaway outlets, is implicated in the causal pathway for the obesity epidemic. This review aims to summarise this body of research and highlight areas for future work. Thirty three studies were found that had assessed the geography of these outlets. Fourteen studies showed a positive association between availability of FF outlets and increasing deprivation. Another 13 studies also included overweight or obesity data and showed conflicting results between obesity/overweight and FF outlet availability. There is some evidence that FF availability is associated with lower fruit and vegetable intake. There is potential for land use policies to have an influence on the location of new FF outlets. Further research should incorporate good quality data on FF consumption, weight and physical activity.

  3. The effect and contribution of wind generated rotation on outlet temperature and heat gain of LS-2 parabolic trough solar collector

    Directory of Open Access Journals (Sweden)

    Sadaghiyani Omid Karimi

    2013-01-01

    Full Text Available The Monte Carlo ray tracing method is applied and coupled with finite volume numerical methods to study effect of rotation on outlet temperature and heat gain of LS-2 parabolic trough concentrator (PTC. Based on effect of sunshape, curve of mirror and use of MCRT, heat flux distribution around of inner wall of evacuated tube is calculated. After calculation of heat flux, the geometry of LS-2 Luz collector is created and finite volume method is applied to simulate. The obtained results are compared with Dudley et al test results for irrotational cases to validate these numerical solving models. Consider that, for rotational models ,the solving method separately with K.S. Ball's results. In this work, according to the structure of mentioned collector, we use plug as a flow restriction. In the rotational case studies, the inner wall rotates with different angular speeds. We compare results of rotational collector with irrotational. Also for these two main states, the location of plug changed then outlet temperature and heat gain of collector are studied. The results show that rotation have positive role on heat transfer processing and the rotational plug in bottom half of tube have better effectual than upper half of tube. Also the contribution of rotation is calculated in the all of case studies. Working fluid of these study is one of the oil derivatives namely Syltherm-800. The power of wind can be used to rotate tube of collector.

  4. Double Outlet Right Ventricle

    Science.gov (United States)

    ... Right Ventricle Menu Topics Topics FAQs Double Outlet Right Ventricle Double outlet right ventricle (DORV) is a rare form of congenital heart disease. En español Double outlet right ventricle (DORV) is a rare form of congenital ...

  5. Alcohol outlets, social disorganization, and robberies: accounting for neighborhood characteristics and alcohol outlet types.

    Science.gov (United States)

    Snowden, Aleksandra J; Freiburger, Tina L

    2015-05-01

    We estimated spatially lagged regression and spatial regime models to determine if the variation in total, on-premise, and off-premise alcohol outlet(1) density is related to robbery density, while controlling for direct and moderating effects of social disorganization.(2) Results suggest that the relationship between alcohol outlet density and robbery density is sensitive to the measurement of social disorganization levels. Total alcohol outlet density and off-premise alcohol outlet density were significantly associated with robbery density when social disorganization variables were included separately in the models. However, when social disorganization levels were captured as a four item index, only the association between off-premise alcohol outlets and robbery density remained significant. More work is warranted in identifying the role of off-premise alcohol outlets and their characteristics in robbery incidents. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Double-outlet right ventricle revisited.

    Science.gov (United States)

    Ebadi, Ameneh; Spicer, Diane E; Backer, Carl L; Fricker, F Jay; Anderson, Robert H

    2017-08-01

    Double-outlet right ventricle is a form of ventriculoarterial connection. The definition formulated by the International Society for Nomenclature of Paediatric and Congenital Heart Disease is based on hearts with both arterial trunks supported in their greater part by a morphologically right ventricle. Bilateral infundibula and ventricular septal defects are highly debated criteria. This study examines the anatomic controversies surrounding double-outlet right ventricle. We show that hearts with double-outlet right ventricle can have atrioventricular-to-arterial valvular continuity. We emphasize the difference between the interventricular communication and the zone of deficient ventricular septation. The hearts examined were from the University of Florida in Gainesville; Johns Hopkins All Children's Hospital, St Petersburg, Fla; and Lurie Children's Hospital, Chicago, Ill. Each specimen had at least 75% of both arterial roots supported by the morphologically right ventricle, with a total of 100 hearts examined. The morphologic method was used to assess anatomic features, including arterial-atrioventricular valvular continuity, subarterial infundibular musculature, and the location of the hole between the ventricles. Most hearts had fibrous continuity between one of the arterial valves and an atrioventricular valve, with bilateral infundibula in 23%, and intact ventricular septum in 5%. Bilateral infundibula are not a defining feature of double-outlet right ventricle, representing only 23% of the specimens in our sample. The interventricular communication can have a posteroinferior muscular rim or extend to become perimembranous (58%). Double-outlet right ventricle can exist with an intact ventricular septum. Copyright © 2017 The American Association for Thoracic Surgery. All rights reserved.

  7. EXERGY AND CARBON CREDITS FOR SERIES CONNECTED N PHOTOVOLTAIC THERMAL - COMPOUND PARABOLIC CONCENTRATOR (PVT-CPC) COLLECTOR: AT CONSTANT OUTLET TEMPERATURE

    OpenAIRE

    Rohit Tripathi 1,*, G. N. Tiwari 2

    2017-01-01

    In the present study, overall energy and exergy performance of partially covered N photovoltaic thermal - compound parabolic concentrators (PVT-CPC) (25% covered by glass to glass PV module) collector connected in series have been carried out at constant outlet temperature mode. Further, comparison in performance for partially covered N photovoltaic thermal - compound parabolic concentrators (PVT-CPC) [case (i)] and N compound parabolic concentrators (CPC) collector [case (ii)] connected in s...

  8. Heat transfer from the evaporator outlet to the charge of thermostatic expansion valves

    DEFF Research Database (Denmark)

    Langmaack, Lasse Nicolai; Knudsen, Hans-Jørgen Høgaard

    2006-01-01

    outlet with a special mounting strap. The heat transfer is quite complex because it takes place both directly through the contact points between bulb and pipe and indirectly through the mounting strap The TXV has to react to temperature changes at the evaporator outlet. Therefore, the dynamic behavior...... of the valve (and thereby the whole refrigeration system) depends greatly on the heat transfer between the evaporator outlet tube and the charge in the bulb. In this paper a model for the overall heat transfer between the pipe and the charge is presented. Geometrical data and material properties have been kept...... been found to predict the time constant for the temperature development in the bulb within 1-10 %. Furthermore it has been found that app. 20% of the heat transfer takes place trough the mounting strap....

  9. Next Generation Nuclear Plant Project Technology Development Roadmaps: The Technical Path Forward for 750–800°C Reactor Outlet Temperature

    Energy Technology Data Exchange (ETDEWEB)

    John Collins

    2009-08-01

    This document presents the NGNP Critical PASSCs and defines their technical maturation path through Technology Development Roadmaps (TDRMs) and their associated Technology Readiness Levels (TRLs). As the critical PASSCs advance through increasing levels of technical maturity, project risk is reduced and the likelihood of within-budget and on-schedule completion is enhanced. The current supplier-generated TRLs and TDRMs for a 750–800°C reactor outlet temperature (ROT) specific to each supplier are collected in Appendix A.

  10. PPOOLEX experiments with a modified blowdown pipe outlet

    International Nuclear Information System (INIS)

    Laine, J.; Puustinen, M.; Raesaenen, A.

    2009-08-01

    This report summarizes the results of the experiments with a modified blowdown pipe outlet carried out with the PPOOLEX test facility designed and constructed at Lappeenranta University of Technology. Steam was blown into the dry well compartment and from there through a vertical DN200 blowdown pipe to the condensation pool. Four reference experiments with a straight pipe and ten with the Forsmark type collar were carried out. The main purpose of the experiment series was to study the effect of a blowdown pipe outlet collar design on loads caused by chugging phenomena (rapid condensation) while steam is discharged into the condensation pool. The PPOOLEX test facility is a closed stainless steel vessel divided into two compartments, dry well and wet well. During the experiments the initial temperature level of the condensation pool water was either 20-25 or 50-55 deg. C. The steam flow rate varied from 400 to 1200 g/s and the temperature of incoming steam from 142 to 185 deg. C. In the experiments with 20-25 deg. C pool water, even 10 times higher pressure pulses were measured inside the blowdown pipe in the case of the straight pipe than with the collar. In this respect, the collar design worked as planned and removed the high pressure spikes from the blowdown pipe. Meanwhile, there seemed to be no suppressing effect on the loads due to the collar in the pool side in this temperature range. Registered loads in the pool were approximately in the same range (or even a little higher) with the collar as with the straight pipe. In the experiments with 50-55 deg. C pool water no high pressure pulses were measured inside the blowdown pipe either with the straight pipe or with the collar. In this case, more of the suppressing effect is probably due to the warmer pool water than due to the modified pipe outlet. It has been observed already in the earlier experiments with a straight pipe in the POOLEX and PPOOLEX facilities that warm pool water has a diminishing effect on

  11. PPOOLEX experiments with a modified blowdown pipe outlet

    Energy Technology Data Exchange (ETDEWEB)

    Laine, J.; Puustinen, M.; Raesaenen, A. (Lappeenranta Univ. of Technology, Nuclear Safety Research Unit (Finland))

    2009-08-15

    This report summarizes the results of the experiments with a modified blowdown pipe outlet carried out with the PPOOLEX test facility designed and constructed at Lappeenranta University of Technology. Steam was blown into the dry well compartment and from there through a vertical DN200 blowdown pipe to the condensation pool. Four reference experiments with a straight pipe and ten with the Forsmark type collar were carried out. The main purpose of the experiment series was to study the effect of a blowdown pipe outlet collar design on loads caused by chugging phenomena (rapid condensation) while steam is discharged into the condensation pool. The PPOOLEX test facility is a closed stainless steel vessel divided into two compartments, dry well and wet well. During the experiments the initial temperature level of the condensation pool water was either 20-25 or 50-55 deg. C. The steam flow rate varied from 400 to 1200 g/s and the temperature of incoming steam from 142 to 185 deg. C. In the experiments with 20-25 deg. C pool water, even 10 times higher pressure pulses were measured inside the blowdown pipe in the case of the straight pipe than with the collar. In this respect, the collar design worked as planned and removed the high pressure spikes from the blowdown pipe. Meanwhile, there seemed to be no suppressing effect on the loads due to the collar in the pool side in this temperature range. Registered loads in the pool were approximately in the same range (or even a little higher) with the collar as with the straight pipe. In the experiments with 50-55 deg. C pool water no high pressure pulses were measured inside the blowdown pipe either with the straight pipe or with the collar. In this case, more of the suppressing effect is probably due to the warmer pool water than due to the modified pipe outlet. It has been observed already in the earlier experiments with a straight pipe in the POOLEX and PPOOLEX facilities that warm pool water has a diminishing effect on

  12. Numerical Simulation of Two-branch Hot Gas Mixing at Reactor Outlet of HTR-PM

    International Nuclear Information System (INIS)

    Hao Pengefei; Zhou Yangping; Li Fu; Shi Lei; He Heng

    2014-01-01

    A series of two-branch model experiment has been finished to investigate the thermal mixing efficiency of the HTR-PM reactor outlet. This paper introduces the numerical simulation on the design of thermal mixing structure of HTR-PM and the test facility with Fluent software. The profiles of temperature, pressure and velocity in the mixing structure design and the test facility are discussed by comparing with the model experiment results. The numerical simulation results of the test facility have good agreement to the experiment results. In addition, the thermal-fluid characters obtained by numerical simulation show the thermal mixing structure of HTR-PM has similarity with the test facility. Finally, it is concluded that the thermal mixing design at HTR-PM reactor outlet can fulfilled the requirements for high thermal mixing efficiency and appropriate pressure drop. (author)

  13. 14 CFR 23.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 23.977 Section 23.977... tank outlet. (a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This... damage any fuel system component. (b) The clear area of each fuel tank outlet strainer must be at least...

  14. Development of neural network driven fuzzy controller for outlet sodium temperature of DHX

    International Nuclear Information System (INIS)

    Okusa, Kyoichi; Endou, Akira; Yoshikawa, Shinji; Ozawa, Kenji

    1996-01-01

    Fuzzy controls are capable to exquisitely control non-linear dynamic systems in wide operating range, using linguistic description to define the control law. However the selection and the definition of the fuzzy rules and sets require a tedious trial and error process based on experience. As a method to overcome this limitation, a neural network driven fuzzy control (NDF), where the learning capability of the neural network (NN) is used to build the fuzzy rules and sets, is presented in this paper. In the NDF control the IF part of a fuzzy control is represented by a multilayer NN while the THEN part is represented by a series of multilayer NNs which calculate the desirable control action. In this work the usual stepwise variable reduction method, used for the selection of the input variable in the THEN part NN, is replaced with a learning algorithm with forgetting mechanism that realizes the automatic reduction of the variables and the tuning up of all the fuzzy control law i.e. the membership function. The NDF has been successfully applied to control the outlet sodium temperature of a dump heat exchanger (DHX) of a FBR plant

  15. Water recovery and air humidification by condensing the moisture in the outlet gas of a proton exchange membrane fuel cell stack

    International Nuclear Information System (INIS)

    Wan, Z.M.; Wan, J.H.; Liu, J.; Tu, Z.K.; Pan, M.; Liu, Z.C.; Liu, W.

    2012-01-01

    Humidification is one of the most important factors for the operation of proton exchange membrane fuel cell (PEMFC). To maintain the membrane at hydrated state, plenty of water is needed for the state-of-the-art of PEMFC technology, especially in large power applications or long time operation. A condenser is introduced to separate liquid water from the air outlet for air self-sufficient in water of the stack in this study. The condensed temperature at the outlet of the condenser and water recovered amount for air self-sufficient in water are investigated theoretically and experimentally. It is shown that the condensed temperature for air self-sufficient in water is irrelevant with the working current of the stack. When the condenser outlet temperature was above the theoretical line, recovery water was not sufficient for the air humidification. On the contrary, it is sufficient while the temperature was below the theoretical line. It is also shown that when the moisture is sufficiently cooled, large amount water can be separated from the outlet gas, and it increased almost linearly with the time. With the introduction of the condenser, the recovered amount of water can easily satisfy the air self-sufficient in water by condensing the outlet gas to a proper temperature. - Highlights: ► We introduce a condenser to separate liquid water from the air outlet in the stack. ► The mechanism of air self-sufficient in water by condensing gas is presented. ► The condensed temperature and water recovered amount are investigated. ► An experiment is present to validate simplicity and feasibility of the criterion. ► The criterion for air humidification is used for choosing the condenser.

  16. Alcohol Outlet Density and Intimate Partner Violence in a Nonmetropolitan College Town: Accounting for Neighborhood Characteristics and Alcohol Outlet Types.

    Science.gov (United States)

    Snowden, Aleksandra J

    2016-01-01

    There is a growing evidence of an ecological association between alcohol outlet density and intimate partner violence. It is reasonable to assume, however, that not all types of alcohol outlets contribute equally to criminal behavior, and to date, most ecological studies have been of large urban cities. Using Bloomington, Indiana, block groups as units of analysis and controlling for several structural characteristics associated with violence rates, I estimated spatially lagged regression models to determine if the variation in alcohol outlet density, including total outlets and disaggregating by on- and off-premise outlets, is related to intimate partner violence density. Results suggested that total alcohol outlet density and off-premise alcohol outlet density were significantly associated with intimate partner violence density. On-premise alcohol outlet density was not significantly associated with intimate partner violence density. These results not only extend the geographic scope of this relationship beyond large metropolitan areas but also have important policy implications.

  17. Decreasing the exhaust outlet temperatures on a class III bus with the lowest impact on the exhaust backpressure and the fuel consumption

    Science.gov (United States)

    Aslan, E.; Ozturk, Y.; Dileroglu, S.

    2017-07-01

    The focus of this study is to determine the most appropriate exhaust tail pipe form among three different type of designs with respect to their temperature loss efficiency for a 9.5m intercity bus equipped with an Euro VI diesel engine and an automated transmission. To provide lower temperatures at the exhaust outlet, mentioned designs were submitted on to a CFD simulation using Ansys Fluent 17.1, while for manufactured products, temperature measurement tests were conducted in an environmental chamber with Omega K-type thermocouples, and Flir T420 thermal camera was used to monitor outer surface temperature distributions to make a comparison between theoretical and practical results. In order to obtain these practical results, actual tests were performed in an environmental chamber with a constant ambient temperature during the vehicle exhaust emission system regeneration process. In conclusion, an exhaust tail pipe design with a diffuser having a circular contraction and expansion forms is designated since it was the most optimized option in terms of temperature loss efficiency, inconsiderable exhaust backpressure increase and manufacturing costs.

  18. Socioeconomic determinants of exposure to alcohol outlets.

    Science.gov (United States)

    Morrison, Christopher; Gruenewald, Paul J; Ponicki, William R

    2015-05-01

    Alcohol outlets tend to be located in lower income areas, exposing lower income populations to excess risks associated with alcohol sales through these establishments. The objective of this study was to test two hypotheses about the etiology of these differential exposures based on theories of the economic geography of retail markets: (a) outlets will locate within or near areas of high alcohol demand, and (b) outlets will be excluded from areas with high land and structure rents. Data from the 2010 National Drug Strategy Household Survey were used to develop a surrogate for alcohol demand (i.e., market potential) at two census geographies for the city of Melbourne, Australia. Bayesian conditional autoregressive Poisson models estimated multilevel spatial relationships between counts of bars, restaurants, and off-premise outlets and market potential, income, and zoning ordinances (Level 1: n = 8,914). Market potentials were greatest in areas with larger older age, male, English-speaking, high-income populations. Independent of zoning characteristics, greater numbers of outlets appeared in areas with greater market potentials and the immediately surrounding areas. Greater income excluded outlets in local and surrounding areas. These findings are consistent with the hypothesis that alcohol outlets are located in areas with high demand and are excluded from high-income areas. These processes appear to take place at relatively small geographic scales, encourage the concentration of outlets in specific low-income areas, and represent a very general economic process likely to take place in communities throughout the world.

  19. Off-premise alcohol outlet characteristics and violence.

    Science.gov (United States)

    Snowden, Aleksandra J; Pridemore, William Alex

    2014-07-01

    There is considerable evidence of an association between alcohol outlet density and violence. Although prior research reveals the importance of specific characteristics of bars on this association and that the relationship between bar density and violence may be moderated by these characteristics, there are few similar studies of the characteristics of off-premise outlets (e.g., liquor and convenience stores). We examined whether immediate environment, business practice, staff, and patron characteristics of off-premise alcohol outlets are associated with simple and aggravated assault density. Cross-sectional design using aggregate data from 65 census block groups in a non-metropolitan college town, systematic social observation, and spatial modeling techniques. We found limited effects of immediate environment, business practice, staff, and patron characteristics on simple assault density and no effect on aggravated assault density. Only two out of 17 characteristics were associated with simple assault density (i.e., nearby library and male patrons). This is the first study to examine the association between several off-premise alcohol outlet characteristics and assault. Our findings suggest that where the off-premise outlets are located, how well the immediate environment is maintained, what types of beverages the outlets sell, who visits them, and who works there matter little in their association with violence. This suggests the importance of outlet density itself as a primary driver of any association with violence. Public policies aimed at reducing alcohol outlet density or clustering may be useful for reducing violence.

  20. 14 CFR 25.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 25.977 Section 25.977... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.977 Fuel tank outlet. (a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This strainer must— (1) For...

  1. 14 CFR 29.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 29.977 Section 29.977... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.977 Fuel tank outlet. (a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This strainer must— (1) For...

  2. 14 CFR 27.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 27.977 Section 27.977... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.977 Fuel tank outlet. (a) There must be a fuel stainer for the fuel tank outlet or for the booster pump. This strainer must— (1) For...

  3. Socioeconomic Determinants of Exposure to Alcohol Outlets

    Science.gov (United States)

    Morrison, Christopher; Gruenewald, Paul J.; Ponicki, William R.

    2015-01-01

    Objective: Alcohol outlets tend to be located in lower income areas, exposing lower income populations to excess risks associated with alcohol sales through these establishments. The objective of this study was to test two hypotheses about the etiology of these differential exposures based on theories of the economic geography of retail markets: (a) outlets will locate within or near areas of high alcohol demand, and (b) outlets will be excluded from areas with high land and structure rents. Method: Data from the 2010 National Drug Strategy Household Survey were used to develop a surrogate for alcohol demand (i.e., market potential) at two census geographies for the city of Melbourne, Australia. Bayesian conditional autoregressive Poisson models estimated multilevel spatial relationships between counts of bars, restaurants, and off-premise outlets and market potential, income, and zoning ordinances (Level 1: n = 8,914). Results: Market potentials were greatest in areas with larger older age, male, English-speaking, high-income populations. Independent of zoning characteristics, greater numbers of outlets appeared in areas with greater market potentials and the immediately surrounding areas. Greater income excluded outlets in local and surrounding areas. Conclusions: These findings are consistent with the hypothesis that alcohol outlets are located in areas with high demand and are excluded from high-income areas. These processes appear to take place at relatively small geographic scales, encourage the concentration of outlets in specific low-income areas, and represent a very general economic process likely to take place in communities throughout the world. PMID:25978830

  4. Intelligent electrical outlet for collective load control

    Science.gov (United States)

    Lentine, Anthony L.; Ford, Justin R.; Spires, Shannon V.; Goldsmith, Steven Y.

    2015-10-27

    Various technologies described herein pertain to an electrical outlet that autonomously manages loads in a microgrid. The electrical outlet can provide autonomous load control in response to variations in electrical power generation supply in the microgrid. The electrical outlet includes a receptacle, a sensor operably coupled to the receptacle, and an actuator configured to selectively actuate the receptacle. The sensor measures electrical parameters at the receptacle. Further, a processor autonomously controls the actuator based at least in part on the electrical parameters measured at the receptacle, electrical parameters from one or more disparate electrical outlets in the microgrid, and a supply of generated electric power in the microgrid at a given time.

  5. MRI of thoracic outlet syndrome in children

    International Nuclear Information System (INIS)

    Chavhan, Govind B.; Batmanabane, Vaishnavi; Muthusami, Prakash; Towbin, Alexander J.; Borschel, Gregory H.

    2017-01-01

    Thoracic outlet syndrome is caused by compression of the neurovascular bundle as it passes from the upper thorax to the axilla. The neurovascular bundle can be compressed by bony structures such as the first rib, cervical ribs or bone tubercles, or from soft-tissue abnormalities like a fibrous band, muscle hypertrophy or space-occupying lesion. Thoracic outlet syndrome commonly affects young adults but can be seen in the pediatric age group, especially in older children. Diagnosis is based on a holistic approach encompassing clinical features, physical examination findings including those triggered by various maneuvers, electromyography, nerve conduction studies and imaging. Imaging is performed to confirm the diagnosis, exclude mimics and classify thoracic outlet syndrome into neurogenic, arterial, venous or mixed causes. MRI and MR angiography are useful in this process. A complete MRI examination for suspected thoracic outlet syndrome should include the assessment of anatomy and any abnormalities using routine sequences, vessel assessment with the arms in adduction by MR angiography and assessment of dynamic compression of vessels with abduction of the arms. The purpose of this paper is to describe the anatomy of the thoracic outlet, causes of thoracic outlet syndrome, the MR imaging techniques used in its diagnosis and the principles of image interpretation. (orig.)

  6. MRI of thoracic outlet syndrome in children

    Energy Technology Data Exchange (ETDEWEB)

    Chavhan, Govind B.; Batmanabane, Vaishnavi [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto, ON (Canada); Muthusami, Prakash [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto, ON (Canada); The Hospital for Sick Children, Division of Image Guided Therapy, Department of Diagnostic Imaging, Toronto, ON (Canada); Towbin, Alexander J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology and Medical Imaging, Cincinnati, OH (United States); Borschel, Gregory H. [The Hospital for Sick Children and University of Toronto, Division of Plastic Surgery, Department of Pediatric Surgery, Toronto, ON (Canada)

    2017-09-15

    Thoracic outlet syndrome is caused by compression of the neurovascular bundle as it passes from the upper thorax to the axilla. The neurovascular bundle can be compressed by bony structures such as the first rib, cervical ribs or bone tubercles, or from soft-tissue abnormalities like a fibrous band, muscle hypertrophy or space-occupying lesion. Thoracic outlet syndrome commonly affects young adults but can be seen in the pediatric age group, especially in older children. Diagnosis is based on a holistic approach encompassing clinical features, physical examination findings including those triggered by various maneuvers, electromyography, nerve conduction studies and imaging. Imaging is performed to confirm the diagnosis, exclude mimics and classify thoracic outlet syndrome into neurogenic, arterial, venous or mixed causes. MRI and MR angiography are useful in this process. A complete MRI examination for suspected thoracic outlet syndrome should include the assessment of anatomy and any abnormalities using routine sequences, vessel assessment with the arms in adduction by MR angiography and assessment of dynamic compression of vessels with abduction of the arms. The purpose of this paper is to describe the anatomy of the thoracic outlet, causes of thoracic outlet syndrome, the MR imaging techniques used in its diagnosis and the principles of image interpretation. (orig.)

  7. Alcohol Outlets and Violent Crime in Washington D.C.

    Directory of Open Access Journals (Sweden)

    Pan, William K

    2010-08-01

    Full Text Available Objective: Alcohol is more likely than any other drug to be involved in substance-related violence. In 2000 violence-related and self-directed injuries accounted for an estimated $37 billion and $33 billion in productivity losses and medical treatment, respectively. A review of emergency department data revealed violence and clinically identified trauma-related injuries have the strongest correlation among alcohol-dependent injuries. At the environmental level there is a relationship between alcohol outlet density and violent crime. A limited number of studies have examined the relationship between alcohol outlet type and the components of violent crime. The aim of this study is to examine the relationship between the aggregate components of violent crime and alcohol outlet density by type of outlet.Methods: For this study we used Washington, D.C. census tract data from the 2000 census to examine neighborhood characteristics. Alcohol outlet, violent crime, and population-level data for Washington, D.C. were drawn from various official yet publicly available sources. We developed an analytic database to examine the relationship between alcohol outlet category and four types of violent crime. After estimating spatial correlation and determining spatial dependence, we used a negative binomial regression analysis to assess the alcohol availability-violent crime association, while controlling for structural correlates of violence.Results: Independent of alternative structural correlates of violent crime, including the prevalence of weapons and illicit drugs, community-level alcohol outlet density is significantly associated with assaultive violence. Outlets were significantly related to robbery, assault, and sexual offenses. In addition, the relationship among on-premise and off-premise outlets varied across violent crime categories.Conclusion: In Washington, D.C., alcohol outlet density is significantly associated with the violent crimes. The

  8. 49 CFR 178.345-11 - Tank outlets.

    Science.gov (United States)

    2010-10-01

    ... unloading of lading, as distinguished from outlets such as manhole covers, vents, vapor recovery devices... away from the loading/unloading outlet. The actuating mechanism must be corrosion-resistant and...

  9. Hydrologic Outlets of the Greenland Ice Sheet

    Data.gov (United States)

    National Aeronautics and Space Administration — The Hydrologic Outlets of the Greenland Ice Sheet data set contains GIS point shapefiles that include 891 observed and potential hydrologic outlets of the Greenland...

  10. Flow visualization study of two phase flow in a single bend outlet feeder pipe and horizontal annulus of outlet end-fitting of a CANDU reactor

    International Nuclear Information System (INIS)

    Supa-Amornkul, S.; Lister, D.H.; Steward, F.R.

    2005-01-01

    'Full text:' In CANDU-6 reactors, the pressurized high-temperature coolant flows through 380 fuel channels passing horizontally through the core. Each end of a fuel channel has a stainless steel annular end-fitting connected to a carbon steel feeder pipe. The outlet coolant, which is at 310 o C with up to 0.30 steam voidage, turns through 90 o as it passes from flow in the annular end-fitting to pipe flow in the feeder via a Grayloc connector. Since 1996, several CANDU stations have reported excessive corrosion of their outlet feeder pipes; especially between the first metre, which consisted of single or double bends. Early studies related the attack to the hydrodynamics of the coolant and verified that it was a type of flow accelerated corrosion. In order to understand the hydrodynamics of the coolant in the outlet feeders by flow-visualization, a full-scale transparent test section simulating the geometry and orientation of an outlet feeder bend with its upstream annular end-fitting were fabricated. The feeder consisted of a 54 mm inside diameter acrylic pipe with a 73 o bend, connecting to an acrylic simulation of a Grayloc flanged fitting and annular end-fitting. The annular end-fitting consisted of an inner pipe, 110 mm outer diameter, and an outer pipe, 150 mm inner diameter, both 190.7 cm long in length. The tests were performed with water and air at atmospheric pressure and room temperature. The maximum water volumetric flow rate was 19 L/s and the volume fraction of air varied from 0.05 to 0.56. The phase distributions within the feeder pipe and along the length of the annulus were investigated with a digital video recorder. Size, concentration and velocity of the air bubbles at particular locations were studied with a high-speed digital still camera and a high-speed digital video camera. Phase distributions and variations in bubble size with velocity were determined. Particular attention was paid to the flow pattern at the inside of the bend, where a CFD

  11. Flow visualization study of two phase flow in a single bend outlet feeder pipe and horizontal annulus of outlet end-fitting of a CANDU reactor

    Energy Technology Data Exchange (ETDEWEB)

    Supa-Amornkul, S.; Lister, D.H.; Steward, F.R. [Univ. of New Brunswick, Fredericton, New Brunswick (Canada)]. E-mail: h796e@unb.ca; dlister@unb.ca; fsteward@unb.ca

    2005-07-01

    'Full text:' In CANDU-6 reactors, the pressurized high-temperature coolant flows through 380 fuel channels passing horizontally through the core. Each end of a fuel channel has a stainless steel annular end-fitting connected to a carbon steel feeder pipe. The outlet coolant, which is at 310{sup o}C with up to 0.30 steam voidage, turns through 90{sup o} as it passes from flow in the annular end-fitting to pipe flow in the feeder via a Grayloc connector. Since 1996, several CANDU stations have reported excessive corrosion of their outlet feeder pipes; especially between the first metre, which consisted of single or double bends. Early studies related the attack to the hydrodynamics of the coolant and verified that it was a type of flow accelerated corrosion. In order to understand the hydrodynamics of the coolant in the outlet feeders by flow-visualization, a full-scale transparent test section simulating the geometry and orientation of an outlet feeder bend with its upstream annular end-fitting were fabricated. The feeder consisted of a 54 mm inside diameter acrylic pipe with a 73{sup o} bend, connecting to an acrylic simulation of a Grayloc flanged fitting and annular end-fitting. The annular end-fitting consisted of an inner pipe, 110 mm outer diameter, and an outer pipe, 150 mm inner diameter, both 190.7 cm long in length. The tests were performed with water and air at atmospheric pressure and room temperature. The maximum water volumetric flow rate was 19 L/s and the volume fraction of air varied from 0.05 to 0.56. The phase distributions within the feeder pipe and along the length of the annulus were investigated with a digital video recorder. Size, concentration and velocity of the air bubbles at particular locations were studied with a high-speed digital still camera and a high-speed digital video camera. Phase distributions and variations in bubble size with velocity were determined. Particular attention was paid to the flow pattern at the inside

  12. Tobacco Retail Outlets and Vulnerable Populations in Ontario, Canada

    Directory of Open Access Journals (Sweden)

    Michael O. Chaiton

    2013-12-01

    Full Text Available Interest has been increasing in regulating the location and number of tobacco vendors as part of a comprehensive tobacco control program. The objective of this paper is to examine the distribution of tobacco outlets in a large jurisdiction, to assess: (1 whether tobacco outlets are more likely to be located in vulnerable areas; and (2 what proportion of tobacco outlets are located close to schools. Retail locations across the Province of Ontario from Ministry of Health Promotion data were linked to 2006 Census data at the neighbourhood level. There was one tobacco retail outlet for every 1,000 people over age 15 in Ontario. Density of outlets varied by public health unit, and was associated with the number of smokers. Tobacco outlets were more likely to be located in areas that had high neighbourhood deprivation, in both rural and urban areas. Outlets were less likely to be located in areas with high immigrant populations in urban areas, with the reverse being true for rural areas. Overall, 65% of tobacco retailers were located within 500 m of a school. The sale of tobacco products is ubiquitous, however, neighbourhoods with lower socio-economic status are more likely to have easier availability of tobacco products and most retailers are located within walking distance of a school. The results suggest the importance of policies to regulate the location of tobacco retail outlets.

  13. Study on thermodynamic cycle of high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Qu Xinhe; Yang Xiaoyong; Wang Jie

    2017-01-01

    The development trend of the (very) High temperature gas-cooled reactor is to gradually increase the reactor outlet temperature. The different power conversion units are required at the different reactor outlet temperature. In this paper, for the helium turbine direct cycle and the combined cycle of the power conversion unit of the High temperature gas-cooled reactor, the mathematic models are established, and three cycle plans are designed. The helium turbine direct cycle is a Brayton cycle with recuperator, precooler and intercooler. In the combined cycle plan 1, the topping cycle is a simple Brayton cycle without recuperator, precooler and intercooler, and the bottoming cycle is based on the steam parameters (540deg, 6 MPa) recommended by Siemens. In the combined cycle plan 2, the topping cycle also is a simple Brayton cycle, and the bottoming cycle which is a Rankine cycle with reheating cycle is based on the steam parameters of conventional subcritical thermal power generation (540degC, 18 MPa). The optimization results showed that the cycle efficiency of the combined cycle plan 2 is the highest, the second is the helium turbine direct cycle, and the combined cycle plan 2 is the lowest. When the reactor outlet temperature is 900degC and the pressure ratio is 2.02, the cycle efficiency of the combined cycle plan 2 can reach 49.7%. The helium turbine direct cycle has a reactor inlet temperature above 500degC due to the regenerating cycle, so it requires a cooling circuit for the internal wall of the reactor pressure vessel. When the reactor outlet temperature increases, the increase of the pressure ratio required by the helium turbine direct cycle increases may bring some difficulties to the design and manufacture of the magnetic bearings. For the combined cycle, the reactor inlet temperature can be controlled below than 370degC, so the reactor pressure vessel can use SA533 steel without cooling the internal wall of the reactor pressure vessel. The pressure

  14. Outlet Glacier-Ice Shelf-Ocean Interactions: Is the Tail Wagging the Dog?

    Science.gov (United States)

    Parizek, B. R.; Walker, R. T.; Rinehart, S. K.

    2009-12-01

    While the massive interior regions of the Antarctic and Greenland Ice Sheets are presently ``resting quietly", the lower elevations of many outlet glaciers are experiencing dramatic adjustments due to changes in ice dynamics and/or surface mass balance. Oceanic and/or atmospheric forcing in these marginal regions often leads to mass deficits for entire outlet basins. Therefore, coupling the wagging tail of ice-ocean interactions with the vast ice-sheet reservoirs is imperative for accurate assessments of future sea-level rise. To study ice-ocean dynamic processes, we couple an ocean-plume model that simulates ice-shelf basal melting rates based on temperature and salinity profiles combined with plume dynamics associated with the geometry of the ice-shelf cavity (following Jenkins, 1991 and Holland and Jenkins, 1999) with a two-dimensional, isothermal model of outlet glacier-ice shelf flow (as used in Alley et al., 2007; Walker et al., 2008; Parizek et al., in review). Depending on the assigned temperature and salinity profiles, the ocean model can simulate both water-mass end-members: either cold High Salinity Shelf Water (HSSW) or relatively warm Circumpolar Deep Water (CDW), as well as between-member conditions. Notably, the coupled system exhibits sensitivity to the initial conditions. In particular, melting concentrated near the grounding line has the greatest effect in forcing grounding-line retreat. Retreat is further enhanced by a positive feedback between the ocean and ice, as the focused melt near the grounding line leads to an increase in the local slope of the basal ice, thereby enhancing buoyancy-driven plume flow and subsequent melt rates.

  15. Measurement of unsteady airflow velocity at nozzle outlet

    Science.gov (United States)

    Pyszko, René; Machů, Mário

    2017-09-01

    The paper deals with a method of measuring and evaluating the cooling air flow velocity at the outlet of the flat nozzle for cooling a rolled steel product. The selected properties of the Prandtl and Pitot sensing tubes were measured and compared. A Pitot tube was used for operational measurements of unsteady dynamic pressure of the air flowing from nozzles to abtain the flow velocity. The article also discusses the effects of air temperature, pressure and relative air humidity on air density, as well as the influence of dynamic pressure filtering on the error of averaged velocity.

  16. The influence of cooling water outlet of the Ringhals power plant on the coastal fish colony

    International Nuclear Information System (INIS)

    Neuman, E.

    1988-03-01

    Fish abundance has been monitored with fyke nets in 1976-1987 at the cooling-water outlet from the Ringhals nuclear power plant at the Swedish west coast and in a reference area. Judging from the dependence of the catches on temperature, Myoxocephalus scorpius, Zoarces viviparus, Gadus morhua and Platichtys flesus can be classified as cold-water species and Symphodus melops, Ctenolabrus rupestris, Carci nus maenas and Anguilla anguilla as warm-water species. As a rule the warm-water species were more and the cold-water fishes less abundant in the outlet area than in the reference area. The catch of the economically important Anguilla was about three times greater in the heated area. A lower abundance than expected of Ctenolabrus and Myoxocephalus at the outlet may be caused by a loss of eggs and larvae in the cooling-water system. (author)

  17. Analysis of the Sales Promotion in Choice Retail Outlet

    OpenAIRE

    HUMPOLCOVÁ, Michaela

    2010-01-01

    My bachelor thesis is aimed at sales promotion in a retail outlet. The main aim of this thesis is evaluate the current state of sales promotion in a selected retail outlet and based on the analysis of the current state of sales promotion in the outlet to try to propose some measures of improve.

  18. Availability of limited service food outlets surrounding schools in British Columbia.

    Science.gov (United States)

    Black, Jennifer L; Day, Meghan

    2012-06-05

    The purpose of this study was to provide a descriptive profile of the availability of limited service food outlets surrounding public schools in British Columbia, Canada. Data from the 2010 Canadian Business Data Files were used to identify limited service food outlets including fast food outlets, beverage and snack food stores, delis and convenience stores. The number of food outlets within 800 metres of 1,392 public schools and the distance from schools to the nearest food outlets were assessed. Multivariate regression models examined the associations between food outlet availability and school-level characteristics. In 2010, over half of the public schools in BC (54%) were located within a 10-12 minute walk from at least one limited service food outlet. The median closest distance to a food outlet was just over 1 km (1016 m). Schools comprised of students living in densely populated urban neighbourhoods and neighbourhoods characterized by lower socio-economic status were more likely to have access to limited service food outlets within walking distance. After adjusting for school-level median family income and population density, larger schools had higher odds of exposure to food vendors compared to schools with fewer students. The availability of and proximity to limited service food outlets vary widely across schools in British Columbia and school-level characteristics are significantly associated with food outlet availability. Additional research is needed to understand how food environment exposures inside and surrounding schools impact students' attitudes, food choices and dietary quality.

  19. Thoracic outlet syndrome: Case report

    International Nuclear Information System (INIS)

    Marquez, Juan Camilo; Acosta, Mauricio Fernando; Uribe Jorge Ricardo

    2009-01-01

    We report a case of vascular thoracic outlet syndrome in a young man, diagnosed with upper limb arteriography, leading to repeated arterio-arterial emboli originating from a post-stenotic subclavian artery aneurysm. It is of our interest due to its low incidence and the small number of cases reported that have been diagnosed by arteriography. The thoracic outlet is the path through which vascular and neural structures goes from the neck to the axilla, and it has three anatomical strictures, that when pronounced, can compress the brachial plexus or subclavian vessels, leading to different symptoms and signs.

  20. Bursting Events in Pressure Flushing with Expanding Bottom Outlet Channel within Dam Reservoir

    Directory of Open Access Journals (Sweden)

    soheila Tofighi

    2017-01-01

    each experiment, the bed level of scouring was measured using laser meters, and the volume of flushing cone was calculated by Surfer software. For investigation of turbulence parameters, the measurement of flow velocity in 0.5cm from the bed of flushing cone in the central axis of the outlet channel in the flow rate of 3 liters per second and water level of 47.5cm for three expansion sizes of the outlet channel (10, 20, and 30cm was performed. The flow velocity measurement was done using an Acoustic Doppler Velocimeter. This device is capable of measuring instantaneous velocity in three directions. Results and Discussion: The results indicated that the relative amount of bottom outlet channel expansion for 0.5, 1 and 1.5 times height of the sediments in the reservoir, leads to increase in flushing cone length for an average of 48, 83 and 113% and flushing cone volume for the average amount of 50, 74 and 96% compared to the case when the outlet channel is not developed. Also the analysis of the turbulence parameters showed that in the nearest axis to the inlet of the bottom outlet channel in which the maximum depth of flushing cone, the occurrence probability of sweep and ejection are maximum and impact angle of moment force due to these events is minimized. However the dominant event here is ejected which was also observed in laboratory experiments the particles were transferred into the channel as suspended load. By increasing the distance from the inlet opening of the channel the occurrence probability of sweep and ejection are decreased and impact angle of moment force due to these events is increased, but again, these two events are the dominant events in this regions and sweep is more important than ejection, that the observations also verify the particles transferred as bed load in these region. Ultimately, it comes to a region where the probabilities of all four events are the same and where the sediment flushing cone reaches the primary sedimentation level that

  1. Development of a solenoid actuated planar valveless micropump with single and multiple inlet-outlet arrangements

    Science.gov (United States)

    Kumar, N.; George, D.; Sajeesh, P.; Manivannan, P. V.; Sen, A. K.

    2016-07-01

    We report a planar solenoid actuated valveless micropump with multiple inlet-outlet configurations. The self-priming characteristics of the multiple inlet-multiple outlet micropump are studied. The filling dynamics of the micropump chamber during start-up and the effects of fluid viscosity, voltage and frequency on the dynamics are investigated. Numerical simulations for multiple inlet-multiple outlet micropumps are carried out using fluid structure algorithm. With DI water and at 5.0 Vp-p, 20 Hz frequency, the two inlet-two outlet micropump provides a maximum flow rate of 336 μl min-1 and maximum back pressure of 441 Pa. Performance characteristics of the two inlet-two outlet micropump are studied for aqueous fluids of different viscosity. Transport of biological cell lines and diluted blood samples are demonstrated; the flow rate-frequency characteristics are studied. Viability of cells during pumping with multiple inlet multiple outlet configuration is also studied in this work, which shows 100% of cells are viable. Application of the proposed micropump for simultaneous pumping, mixing and distribution of fluids is demonstrated. The proposed integrated, standalone and portable micropump is suitable for drug delivery, lab-on-chip and micro-total-analysis applications.

  2. Temperature distribution in the Temelin NPP primary circuit piping

    International Nuclear Information System (INIS)

    Blaha, V.; Maca, K.; Kodl, P.; Kroj, L.

    2004-01-01

    Temperature non-homogeneity in the VVER 1000 reactor primary piping hot legs was detected during the commissioning of Temelin units 1 and 2. A quantification of temperature differences was carried out and explanation of its causes was presented. Mathematical analysis of the effect was carried out using the PHOENICS 3.4 code, and the results were processed graphically by means of a post processor PHOTON and by means of a user program allowing statistic evaluation of temperature profiles at the core outlet and in the area of the temperature-measurement pits. The coolant temperatures in the core area increased gradually following the given radial and axial distribution of output from the inlet temperature of 288.1 degC to 315-331 degC at the core outlet. The temperature profile was balanced and in the IO piping in the area of temperature-measurement pits the difference of the maximum and minimum temperature value was approx. 1 degC according to the calculation. The temperature field shape is mainly determined by the radial distribution of the core output. The mean outlet temperature from the core weighted through mass flow is determined by the flow through the core and by the total output. The calculated temperature span at the core outlet in the range of 315 - 331 degC corresponded well with the measured values during the operation. The values were in the range of 310-333 degC, however, the in-core thermocouple inaccuracy should also be taken into consideration. On the other hand, the temperature span in the area of temperature-measurement pits was actually about 4 times higher than the calculated temperature (observed: 4 degC as against the calculated 1 degC). A good agreement was reached between the analysis results and the actual condition of the nuclear unit in the area of the core outlet. (P.A.)

  3. Patterning of neighbourhood food outlets and longitudinal associations with children's eating behaviours.

    Science.gov (United States)

    Timperio, Anna; Crawford, David; Leech, Rebecca M; Lamb, Karen E; Ball, Kylie

    2018-06-01

    This study examined cross-sectional and prospective associations between typologies of neighbourhood food environment and dietary patterns among 10-12 year-old children. Baseline data were collected in 2003 and follow-up data in 2006 from children in Melbourne or Geelong. Parents completed a food frequency questionnaire at both time points. 'Healthful' and 'energy-dense' dietary pattern scores were computed. A Geographic Information System was used to determine the presence or absence of food outlets (cafés/restaurant; fast food; supermarkets/grocery stores; convenience store; greengrocer; and butcher, seafood or poultry retailer) within an 800 m road network buffer of home. Three typologies were identified: 1-variety of food outlets, including those selling core/fresh foods (n = 96); 2-café/restaurant and convenience (n = 160); 3-few types of outlets (n = 208). Latent class analysis was used to identify underlying unobservable typologies of neighbourhood food outlet availability. Linear mixed models were fitted to determine cross-sectional (n = 439) and longitudinal (n = 173) associations between the three identified neighbourhood typologies and each (log-transformed) dietary pattern, accounting for clustering within families and schools. There was little evidence of cross-sectional associations. The longitudinal analyses showed that compared to those with a variety of food outlets, those with few types had 25% lower scores for the healthful dietary pattern (p < 0.05) three years later. For optimal dietary patterns, availability of a variety of food outlets close to home, particularly those where core/fresh foods are available, may be important. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Alcohol beverage control, privatization and the geographic distribution of alcohol outlets

    Directory of Open Access Journals (Sweden)

    Grubesic Tony H

    2012-11-01

    Full Text Available Abstract Background With Pennsylvania currently considering a move away from an Alcohol Beverage Control state to a privatized alcohol distribution system, this study uses a spatial analytical approach to examine potential impacts of privatization on the number and spatial distribution of alcohol outlets in the city of Philadelphia over a long time horizon. Methods A suite of geospatial data were acquired for Philadelphia, including 1,964 alcohol outlet locations, 569,928 land parcels, and school, church, hospital, park and playground locations. These data were used as inputs for exploratory spatial analysis to estimate the expected number of outlets that would eventually operate in Philadelphia. Constraints included proximity restrictions (based on current ordinances regulating outlet distribution of at least 200 feet between alcohol outlets and at least 300 feet between outlets and schools, churches, hospitals, parks and playgrounds. Results Findings suggest that current state policies on alcohol outlet distributions in Philadelphia are loosely enforced, with many areas exhibiting extremely high spatial densities of outlets that violate existing proximity restrictions. The spatial model indicates that an additional 1,115 outlets could open in Philadelphia if privatization was to occur and current proximity ordinances were maintained. Conclusions The study reveals that spatial analytical approaches can function as an excellent tool for contingency-based “what-if” analysis, providing an objective snapshot of potential policy outcomes prior to implementation. In this case, the likely outcome is a tremendous increase in alcohol outlets in Philadelphia, with concomitant negative health, crime and quality of life outcomes that accompany such an increase.

  5. The 3D thermal-hydraulic numerical simulation for the fuel zone outlet of China experimental fast reactor

    International Nuclear Information System (INIS)

    Xue Xiuli; Yang Hongyi; Yang Fuchang

    2008-01-01

    Detailed 3D thermal-hydraulic numerical analyses to the fuel zone outlet are actualized with the STAR-CD CFD code. The performance of sodium mixing is studied and detailed velocity and temperature distribution are obtained in this region which will offer foundations and references to study the rationality of temperature monitoring-spot arrangement and to assess the effect of temperature fluctuations to control rod guide tubes in this region, and so on. (authors)

  6. Temperature of gas delivered from ventilators.

    Science.gov (United States)

    Chikata, Yusuke; Onodera, Mutsuo; Imanaka, Hideaki; Nishimura, Masaji

    2013-01-01

    Although heated humidifiers (HHs) are the most efficient humidifying device for mechanical ventilation, some HHs do not provide sufficient humidification when the inlet temperature to the water chamber is high. Because portable and home-care ventilators use turbines, blowers, pistons, or compressors to inhale in ambient air, they may have higher gas temperature than ventilators with piping systems. We carried out a bench study to investigate the temperature of gas delivered from portable and home-care ventilators, including the effects of distance from ventilator outlet, fraction of inspiratory oxygen (FIO2), and minute volume (MV). We evaluated five ventilators equipped with turbine, blower, piston, or compressor system. Ambient air temperature was adjusted to 24°C ± 0.5°C, and ventilation was set at FIO2 0.21, 0.6, and 1.0, at MV 5 and 10 L/min. We analyzed gas temperature at 0, 40, 80, and 120 cm from ventilator outlet and altered ventilator settings. While temperature varied according to ventilators, the outlet gas temperature of ventilators became stable after, at the most, 5 h. Gas temperature was 34.3°C ± 3.9°C at the ventilator outlet, 29.5°C ± 2.2°C after 40 cm, 25.4°C ± 1.2°C after 80 cm and 25.1°C ± 1.2°C after 120 cm (P < 0.01). FIO2 and MV did not affect gas temperature. Gas delivered from portable and home-care ventilator was not too hot to induce heated humidifier malfunctioning. Gas soon declined when passing through the limb.

  7. Hydrologic Outlets of the Greenland Ice Sheet, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Hydrologic Outlets of the Greenland Ice Sheet data set contains GIS point shapefiles that include 891 observed and potential hydrologic outlets of the Greenland...

  8. AGU hydrology publication outlets

    Science.gov (United States)

    Freeze, R. Allan

    In recent months I have been approached on several occasions by members of the hydrology community who asked me which of the various AGU journals and publishing outlets would be most suitable for a particular paper or article that they have prepared.Water Resources Research (WRR) is the primary AGU outlet for research papers in hydrology. It is an interdisciplinary journal that integrates research in the social and natural sciences of water. The editors of WRR invite original contributions in the physical, chemical and biological sciences and also in the social and policy sciences, including economics, systems analysis, sociology, and law. The editor for the physical sciences side of the journal is Donald R. Nielson, LAWR Veihmeyer Hall, University of California Davis, Davis, CA 95616. The editor for the policy sciences side of the journal is Ronald G. Cummings, Department of Economics, University of New Mexico, Albuquerque, NM 87131

  9. Acute Alcohol Consumption, Alcohol Outlets, and Gun Suicide

    Science.gov (United States)

    Branas, Charles C.; Richmond, Therese S.; Ten Have, Thomas R.; Wiebe, Douglas J.

    2014-01-01

    A case–control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed. PMID:21929327

  10. Coolant mixing in LMFBR rod bundles and outlet plenum mixing transients. Progress report, December 1, 1975--February 29, 1976

    International Nuclear Information System (INIS)

    Todreas, N.E.; Golay, M.W.

    1976-01-01

    Progress is summarized in the following task areas: assessment of available data, experimental water mixing investigations, analytic model development, and analytical and experimental investigation of velocity and temperature fields in outlet plenum flow mixing

  11. Improvement of seawater booster pump outlet check valve

    International Nuclear Information System (INIS)

    Li Xuning; Du Yansong; Huang Huimin

    2010-01-01

    Conventional island seawater booster pump set of QNPC 310 MWe unit are very important in the whole circulating cooling system, and the integrate function of seawater booster pump outlet check valve is the foundation of steady operation of the seawater booster pump set. The article mainly introduce that through the analyses to the reason to the problem that the seawater booster pump outlet check valve of QNPC 310 MWe unit appeared in past years by our team, and considering the influence of operation condition and circumstance, the team improve the seawater booster pump outlet check valve from swing check valve to shuttle check valve which operate more appropriately in the system. By the test of continuous practice, we make further modification to the inner structure of shuttle check valve contrapuntally, and therefore we solve the problem in seawater booster pump outlet check valve fundamentally which has troubled the security of system operation in past years, so we realize the aim of technical improvement and ensure that the system operate in safety and stability. (authors)

  12. Assessments of lake profiling on temperature, Total Suspended ...

    African Journals Online (AJOL)

    Interpolation were performed on temperature, total suspended solid (TSS) and turbidity (TUR) based on in-situ and ex-situ analyses according to the correlation matrix and linear regression at 14 different depths for the Chomor River and Mahadir Island. The result showed outlet significantly decreased over depth caused the ...

  13. The premises is the premise: understanding off- and on-premises alcohol sales outlets to improve environmental alcohol prevention strategies.

    Science.gov (United States)

    Chinman, Matthew; Burkhart, Q; Ebener, Patricia; Fan, Cha-Chi; Imm, Pamela; Osilla, Karen Chan; Paddock, Susan M; Wright, Annie

    2011-06-01

    Environmental strategies to prevent the misuse of alcohol among youth--e.g., use of public policies to restrict minors' access to alcohol--have been shown to reduce underage drinking. However, implementation of policy changes often requires public and private partnerships. One way to support these partnerships is to better understand the target of many of the environmental strategies, which is the alcohol sales outlet. Knowing more about how off-premises outlets (e.g., liquor and convenience stores) and on-premises outlets (e.g., bars and restaurants) are alike and different could help community-based organizations better tailor, plan, and implement their environmental strategies and strengthen partnerships between the public and commercial sectors. We conducted a survey of managerial or supervisory staff and/or owners of 336 off- and on-premises alcohol outlets in six counties in South Carolina, comparing these two outlet types on their preferences regarding certain alcohol sales practices, beliefs toward underage drinking, alcohol sales practices, and outcomes. Multilevel logistic regression showed that while off- and on-premises outlets did have many similarities, off-premises outlets appear to engage in more practices designed to prevent sales of alcohol to minors than on-premises outlets. The relationship between certain Responsible Beverage Service (RBS) practices and outcomes varied by outlet type. This study furthers the understanding of the differences between off- and on-premises alcohol sales outlets and offers options for increasing and tailoring environmental prevention efforts to specific settings.

  14. A longitudinal analysis of alcohol outlet density and domestic violence.

    Science.gov (United States)

    Livingston, Michael

    2011-05-01

    A small number of studies have identified a positive relationship between alcohol outlet density and domestic violence. These studies have all been based on cross-sectional data and have been limited to the assessment of ecological correlations between outlet density and domestic violence rates. This study provides the first longitudinal examination of this relationship. Cross-sectional time-series using aggregated data from small areas. The relationships between alcohol outlet density and domestic violence were assessed over time using a fixed-effects model. Controls for the spatial autocorrelation of the data were included in the model. The study uses data for 186 postcodes from within the metropolitan area of Melbourne, Australia for the years 1996 to 2005. Alcohol outlet density measures for three different types of outlets (hotel/pub, packaged liquor, on-premise) were derived from liquor licensing records and domestic violence rates were calculated from police-recorded crime data, based on the victim's postcode. Alcohol outlet density was associated significantly with rates of domestic violence, over time. All three licence categories were positively associated with domestic violence rates, with small effects for general (pub) and on-premise licences and a large effect for packaged liquor licences. In Melbourne, the density of liquor licences is positively associated with rates of domestic violence over time. The effects were particularly large for packaged liquor outlets, suggesting a need for licensing policies that pay more attention to o off-premise alcohol availability. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.

  15. Gastric Outlet Obstruction from Duodenal Lipoma in an Adult ...

    African Journals Online (AJOL)

    Gastric Outlet Obstruction from Duodenal Lipoma in an Adult. ... Nigerian Journal of Surgery ... Although, peptic ulcer disease remains the most common benign cause of gastric outlet obstruction (GOO), duodenal lipomas remain a rare, but possible cause of GOO and could pose a diagnostic challenge, especially in ...

  16. High temperature corrosion investigations at AW2-bio. Final report; Biomass boiler

    Energy Technology Data Exchange (ETDEWEB)

    Borg, U.

    2011-01-15

    The measured corrosion rates in the test superheaters and ordinary superheaters of Avedoere 2 biomass boiler reveal that the corrosion rate increases with metal temperature and is significantly accelerated above steam temperatures of 540 deg. C. For the boiler with a live steam temperature of 540 deg. C, the measured corrosion rates in superheater 2 and 3 were up to 1mm pr. 10000 hours. It was observed that the flue gas temperature and heat flux had a significant effect on the corrosion rates through the surface metal temperature. Thus, the highest corrosion rates in the ordinary superheaters were not found at the position of the highest steam temperature in the outlet of superheater 3, but at the outlet of superheater 2. A steam temperature of approximately 580 deg. C at the outlet of one of the test superheater loops caused a tube fracture after a few months. A HVOF coating was applied to a section of superheater 2 and at a higher temperature in the test superheater loop. Analyses of the tube section after exposure showed that parts of the coating were not present and corrosion of the underlying TP347H FG was apparent. This indicates that the coating had spalled during operation. Furthermore, chlorine diffusion through the coating was observed causing attack at the coating-alloy interface. The project work has shown that it is not possible to increase the live steam temperature of the biomass fired boiler to more than 540 deg. C without a significant increase in superheater corrosion rates for the applied tube materials and coatings. (Author)

  17. Neighbourhood fast food outlets and obesity in children and adults: the CLAN Study.

    Science.gov (United States)

    Crawford, David A; Timperio, Anna F; Salmon, Jo A; Baur, Louise; Giles-Corti, Billie; Roberts, Rebecca J; Jackson, Michelle L; Andrianopoulos, Nick; Ball, Kylie

    2008-01-01

    We examined associations between density of and proximity to fast food outlets and body weight in a sample of children (137 aged 8-9 years and 243 aged 13-15 years) and their parents (322 fathers and 362 mothers). Children's measured and parents' self-reported heights and weights were used to calculate body mass index (BMI). Locations of major fast food outlets were geocoded. Bivariate linear regression analyses examined associations between the presence of any fast food outlet within a 2 km buffer around participants' homes, fast food outlet density within the 2 km buffer, and distance to the nearest outlet and BMI. Each independent variable was also entered into separate bivariate logistic regression analyses to predict the odds of being overweight or obese. Among older children, those with at least one outlet within 2 km had lower BMI z-scores. The further that fathers lived from an outlet, the higher their BMI. Among 13-15-year-old girls and their fathers, the likelihood of overweight/obesity was reduced by 80% and 50%, respectively, if they had at least one fast food outlet within 2 km of their home. Among older girls, the likelihood of being overweight/obese was reduced by 14% with each additional outlet within 2 km. Fathers' odds of being overweight/obese increased by 13% for each additional kilometre to the nearest outlet. While consumption of fast food has been shown to be associated with obesity, this study provides little support for the concept that exposure to fast food outlets in the local neighbourhood increases risk of obesity.

  18. Evaluation of alcohol outlet density and its relation with violence

    Directory of Open Access Journals (Sweden)

    Laranjeira Ronaldo

    2002-01-01

    Full Text Available OBJECTIVES: The current study set out to investigate alcohol availability in a densely populated, residential area of suburban São Paulo associated with high levels of social deprivation and violence. Gun-related deaths and a heavy concentration of alcohol outlets are notable features of the area surveyed. Given the strong evidence for a link between alcohol availability and a number of alcohol-related problems, including violent crime, measures designed to reduce accessibility have become a favored choice for alcohol prevention programs in recent years. METHODS: The interviewers were 24 residents of the area who were trained for the study. It was selected an area of nineteen streets, covering a total distance of 3.7 km. A profile of each alcohol outlet available on the area was recorded. RESULTS: One hundred and seven alcohol outlets were recorded. The number of other properties in the same area was counted at 1,202. Two measures of outlet density may thus be calculated: the number of outlets per kilometer of roadway (29 outlets/km; and the proportion of all properties that sold alcohol (1 in 12. CONCLUSIONS: The results of this study is compared with others which are mainly from developed countries and shown that the area studied have the highest density of alcohol outlet density ever recorded in the medical literature. The implication of this data related to the violence of the region is discussed. By generating a profile of alcohol sales and selling points, it was hoped to gain a better understanding of alcohol access issues within the sample area. Future alcohol prevention policy would be well served by such knowledge.

  19. Glacier dynamics over the last quarter of a century at Helheim, Kangerdlugssuaq and 14 other major Greenland outlet glaciers

    Directory of Open Access Journals (Sweden)

    S. L. Bevan

    2012-09-01

    Full Text Available The Greenland ice sheet is experiencing increasing rates of mass loss, the majority of which results from changes in discharge from tidewater glaciers. Both atmospheric and ocean drivers have been implicated in these dynamic changes, but understanding the nature of the response has been hampered by the lack of measurements of glacier flow rates predating the recent period of warming. Here, using Landsat-5 data from 1985 onwards, we extend back in time the record of surface velocities and ice-front position for 16 of Greenland's fastest-flowing tidewater glaciers, and compare these to more recent data from Landsat-7 and satellite-borne synthetic-aperture radar. Climate re-analysis data and sea surface temperatures from 1982 show that since 1995 most of Greenland and its surrounding oceans have experienced significant overall warming, and a switch to a warming trend. During the period from 1985 to 1995 when Greenland and the surrounding oceans were not warming, major tidewater outlet glaciers around Greenland, including Kangerdlugssuaq and Helheim, were dynamically stable. Since the mid-1990s, glacier discharge has consistently been both greater and more variable. Together, these observations support the hypothesis that recent dynamic change is a rapid response to climate forcing. Both air and ocean temperatures in this region are predicted to continue to warm, and will therefore likely drive further change in outlet glacier discharge.

  20. Boundary conditions for free surface inlet and outlet problems

    KAUST Repository

    Taroni, M.

    2012-08-10

    We investigate and compare the boundary conditions that are to be applied to free-surface problems involving inlet and outlets of Newtonian fluid, typically found in coating processes. The flux of fluid is a priori known at an inlet, but unknown at an outlet, where it is governed by the local behaviour near the film-forming meniscus. In the limit of vanishing capillary number Ca it is well known that the flux scales with Ca 2/3, but this classical result is non-uniform as the contact angle approaches π. By examining this limit we find a solution that is uniformly valid for all contact angles. Furthermore, by considering the far-field behaviour of the free surface we show that there exists a critical capillary number above which the problem at an inlet becomes over-determined. The implications of this result for the modelling of coating flows are discussed. © 2012 Cambridge University Press.

  1. Ectopic pancreas causing partial gastric outlet obstruction: a case ...

    African Journals Online (AJOL)

    Ectopic pancreas causing partial gastric outlet obstruction: a case report and review of literature. ... Nigerian Journal of Surgery ... Gastric outlet obstruction resulting from ectopic pancreas in an adult is the first of its kind in our center; we, therefore, present this case to describe the challenges faced with diagnosis, treatment, ...

  2. Ectopic Pancreas Causing Partial Gastric Outlet Obstruction: A Case ...

    African Journals Online (AJOL)

    Ectopic pancreas is a rare cause of gastric outlet obstruction, perhaps rarer still among Africans. Although the entity is known, the diagnostic challenges are enormous, especially in the poor‑resource environment. Gastric outlet obstruction resulting from ectopic pancreas in an adult is the first of its kind in our center;.

  3. Coolant mixing in LMFBR rod bundles and outlet plenum mixing transients. Progress report, March 1, 1977--May 31, 1977

    International Nuclear Information System (INIS)

    Todreas, N.E.; Golay, M.W.; Wolf, L.

    1977-01-01

    Progress is summarized in the following tasks: (1) bundle flow studies (wrapped and bare rods); (2) subchannel flow studies (bare rods); (3) LMFBR outlet plenum flow mixing; and (4) theoretical determination of local temperature fields in LMFBR fuel rod bundles

  4. Laboratory services series: an electrical outlet and corded equipment inspection program

    International Nuclear Information System (INIS)

    Davis, E.A.

    1976-04-01

    A research and development laboratory has thousands of electrical outlets providing power to laboratories, offices, shops, and service areas. These outlets provide power for a wide variety of portable equipment and tools that are equipped with cord and plug. Electric safety requires a periodic check of outlet grounding capability and continuing inspection and repair of corded equipment. Personnel, equipment, reports, procedures, and schedule requirements are reported

  5. R/S analysis based study on long memory about CODMn in Poyang Lake Inlet and Outlet

    Science.gov (United States)

    Wang, Lili

    2018-02-01

    Rescaled range analysis (R/S) is applied to the long memory behavior analysis of water CODMn series in Poyang Lake Inlet and Outlet in China. The results show that these CODMn series are characterized by long memory, and the characteristics have obvious differences between the Lake Inlet and Outlet. Our findings suggest that there was an obvious scale invariance, namely CODMn series in Lake Inlet for 13 weeks and CODMn in Lake Outlet for 17 weeks. Both displayed a two-power-law distribution and a similar high long memory. We made a preliminary explanation for the existence of the boundary point tc , using self-organized criticality. This work can be helpful to improvement of modelling of lake water quality.

  6. Alcohol outlet density and alcohol consumption in Los Angeles county and southern Louisiana

    Directory of Open Access Journals (Sweden)

    Matthias Schonlau

    2008-11-01

    Full Text Available The objective of this study was to assess the relationship between alcohol availability, as measured by the density of off-premise alcohol outlets, and alcohol consumption in Los Angeles county and southern Louisiana, USA. Consumption information was collected through a telephone survey of 2,881 households in Los Angeles county and pre-Katrina southern Louisiana, nested within 220 census tracts. Respondents’ addresses were geo-coded and both neighbourhood (census tracts and buffers of varying sizes and individual (network distance to the closest alcohol outlet estimates of off-sale alcohol outlet density were computed. Alcohol outlet density was not associated with the percentage of people who were drinkers in either site. Alcohol outlet density was associated with the quantity of consumption among drinkers in Louisiana but not in Los Angeles. Outlet density within a one-mile buffer of the respondent’s home was more strongly associated with alcohol consumption than outlet density in the respondent’s census tract. The conclusion is that the relationship between neighbourhood alcohol outlet density and alcohol consumption is complex and may vary due to differences in neighbourhood design and travel patterns.

  7. Out-of-home food outlets and area deprivation: case study in Glasgow, UK

    Directory of Open Access Journals (Sweden)

    Cummins Steven

    2005-10-01

    Full Text Available Abstract Background There is a popular belief that out-of-home eating outlets, which typically serve energy dense food, may be more commonly found in more deprived areas and that this may contribute to higher rates of obesity and related diseases in such areas. Methods We obtained a list of all 1301 out-of-home eating outlets in Glasgow, UK, in 2003 and mapped these at unit postcode level. We categorised them into quintiles of area deprivation using the 2004 Scottish Index of Multiple Deprivation and computed mean density of types of outlet (restaurants, fast food restaurants, cafes and takeaways, and all types combined, per 1000 population. We also estimated odds ratios for the presence of any outlets in small areas within the quintiles. Results The density of outlets, and the likelihood of having any outlets, was highest in the second most affluent quintile (Q2 and lowest in the second most deprived quintile (Q4. Mean outlets per 1,000 were 4.02 in Q2, 1.20 in Q4 and 2.03 in Q5. With Q2 as the reference, Odds Ratios for having any outlets were 0.52 (CI 0.32–0.84 in Q1, 0.50 (CI 0.31 – 0.80 in Q4 and 0.61 (CI 0.38 – 0.98 in Q5. Outlets were located in the City Centre, West End, and along arterial roads. Conclusion In Glasgow those living in poorer areas are not more likely to be exposed to out-of-home eating outlets in their neighbourhoods. Health improvement policies need to be based on empirical evidence about the location of fast food outlets in specific national and local contexts, rather than on popular 'factoids'.

  8. Simulation of water flows in multiple columns with small outlets

    International Nuclear Information System (INIS)

    Suh, Yong Kweon; Li, Zi Lu; Jeong, Jong Hyun; Lee, Jun Hee

    2006-01-01

    High-pressure die casting such as thixocasting and rheocasting is an effective process in the manufacturing automotive parts. Following the recent trend in the automotive manufacturing technologies, the product design subject to the die casting becomes more and more complex. Simultaneously the injection speed is also designed to be very high to establish a short cycle-time. Thus, the requirement of the die design becomes more demanding than ever before. In some cases the product's shape can have multiple slender manifolds. In such cases, design of the inlet and outlet parts of the die is very important in the whole manufacturing process. The main issues required for the qualified products are to attain gentle and uniform flow of the molten liquid within the passages of the die. To satisfy such issues, the inlet cylinder ('bed cylinder' in this paper) must be as large as possible and simultaneously the outlet opening at the end of each passage must be as small as possible. However these in turn obviously bring additional manufacturing costs caused by re-melting of the bed cylinder and increased power due to the small outlet-openings. The purpose of this paper is to develop effective simulation methods of calculation for fluid flows in multiple columns, which mimic the actual complex design, and to get some useful information which can give some contributions to the die-casting industry. We have used a commercial code CFX in the numerical simulation. The primary parameter involved is the size of the bed cylinder. We will show how the very small opening of the outlet can be treated with the aid of the porous model provided in the code. To check the validity of the numerical results we have also conducted a simple experiment by using water

  9. On the prediction of condenser plate temperatures in a cross-flow condenser

    NARCIS (Netherlands)

    Ganzevles, F.L.A.; Geld, van der C.W.M.

    2002-01-01

    A prediction method is presented for the gas-sided plate temperatures at the inlet and at the outlet of a compact, cross-flow condenser. The method employs measured (or predicted) heat flow rates and temperatures of both coolant and gas, at inlet and outlet. The method is validated using infrared

  10. Analytical model for transient fluid mixing in upper outlet plenum of an LMFBR

    International Nuclear Information System (INIS)

    Yang, J.W.; Agrawal, A.K.

    1976-01-01

    A two-zone mixing model based on the lumped-parameter approach was developed for the analysis of transient thermal response in the outlet plenum of an LMFBR. The maximum penetration of core flow is used as the criterion for dividing the sodium region into two mixing zones. The model considers the transient sodium temperature affected by the thermal expansion of sodium, heat transfer with cover gas, heat capacity of different sections of metal and the addition of by-pass flow into the plenum. The results of numerical calculations indicate that effects of flow stratification, chimney height, metal heat capacity and by-pass flow are important for transient sodium temperature calculation. Thermal expansion of sodium and heat transfer with the cover gas do not play any significant role on sodium temperature

  11. Development of thermal mixing enhancement method for lower plenum of the High Temperature Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gradecka, Malwina Joanna, E-mail: malgrad@gmail.com; Woods, Brian G., E-mail: brian.woods@oregonstate.edu

    2016-08-15

    Highlights: • Coolant mixing in lower plenum might be insufficient and pose operational issues. • Two mixing methods were developed to lower the coolant temperature variation. • The methods resulted with reduction of the temperature variation by 60% and 71%. - Abstract: The High Temperature Gas-cooled Reactor (HTGR) is one of the most mature Gen IV reactor concepts under development today. The High Temperature Test Facility (HTTF) at Oregon State University is a test facility that supports the R&D needs for HTGRs. This study focuses on the issue of helium mixing after the core section in the HTTF, the results of which are generally applicable in HTGRs. In the HTTF, hot helium jets at different temperatures are supposed to uniformly mix in the lower plenum (LP) chamber. However, the level of mixing is not sufficient to reduce the peak helium temperature before the hot jet impinges the LP structure, which can cause issues with structural materials and operational issues in the heat exchanger downstream. The maximum allowable temperature variation in the outlet duct connected to the lower plenum is defined as 40 K (±20 K from the average temperature), while the CFD simulations of this study indicate that the reference design suffers temperature variations in the duct as high as 100 K. To solve this issue, the installation of mixing-enhancing structures within the outlet duct were proposed and analyzed using CFD modeling. We show that using either an optimized “Kwiat” structure (developed in this study) or a motionless mixer installed in the outlet duct, the temperature variations can be brought dramatically, with acceptable increases in pressure drop. The optimal solution appears to be to install double motionless mixers with long blades in the outlet duct, which brings the temperature variation into the acceptable range (from 100 K down to 18 K), with a resulting pressure drop increase in the HTTF loop of 0.73 kPa (6% of total pressure drop).

  12. Development of thermal mixing enhancement method for lower plenum of the High Temperature Test Facility

    International Nuclear Information System (INIS)

    Gradecka, Malwina Joanna; Woods, Brian G.

    2016-01-01

    Highlights: • Coolant mixing in lower plenum might be insufficient and pose operational issues. • Two mixing methods were developed to lower the coolant temperature variation. • The methods resulted with reduction of the temperature variation by 60% and 71%. - Abstract: The High Temperature Gas-cooled Reactor (HTGR) is one of the most mature Gen IV reactor concepts under development today. The High Temperature Test Facility (HTTF) at Oregon State University is a test facility that supports the R&D needs for HTGRs. This study focuses on the issue of helium mixing after the core section in the HTTF, the results of which are generally applicable in HTGRs. In the HTTF, hot helium jets at different temperatures are supposed to uniformly mix in the lower plenum (LP) chamber. However, the level of mixing is not sufficient to reduce the peak helium temperature before the hot jet impinges the LP structure, which can cause issues with structural materials and operational issues in the heat exchanger downstream. The maximum allowable temperature variation in the outlet duct connected to the lower plenum is defined as 40 K (±20 K from the average temperature), while the CFD simulations of this study indicate that the reference design suffers temperature variations in the duct as high as 100 K. To solve this issue, the installation of mixing-enhancing structures within the outlet duct were proposed and analyzed using CFD modeling. We show that using either an optimized “Kwiat” structure (developed in this study) or a motionless mixer installed in the outlet duct, the temperature variations can be brought dramatically, with acceptable increases in pressure drop. The optimal solution appears to be to install double motionless mixers with long blades in the outlet duct, which brings the temperature variation into the acceptable range (from 100 K down to 18 K), with a resulting pressure drop increase in the HTTF loop of 0.73 kPa (6% of total pressure drop).

  13. Cooling Characteristics of the V-1650-7 Engine. II - Effect of Coolant Conditions on Cylinder Temperatures and Heat Rejection at Several Engine Powers

    Science.gov (United States)

    Povolny, John H.; Bogdan, Louis J.; Chelko, Louis J.

    1947-01-01

    An investigation has been conducted on a V-1650-7 engine to determine the cylinder temperatures and the coolant and oil heat rejections over a range of coolant flows (50 to 200 gal/min) and oil inlet temperatures (160 to 2150 F) for two values of coolant outlet temperature (250 deg and 275 F) at each of four power conditions ranging from approximately 1100 to 2000 brake horsepower. Data were obtained for several values of block-outlet pressure at each of the two coolant outlet temperatures. A mixture of 30 percent by volume of ethylene glycol and 70-percent water was used as the coolant. The effect of varying coolant flow, coolant outlet temperature, and coolant outlet pressure over the ranges investigated on cylinder-head temperatures was small (0 deg to 25 F) whereas the effect of increasing the engine power condition from ll00 to 2000 brake horsepower was large (maximum head-temperature increase, 110 F).

  14. Gastric Adenocarcinoma Presenting with Gastric Outlet Obstruction in a Child

    Directory of Open Access Journals (Sweden)

    Abdulrahman Al-Hussaini

    2014-01-01

    Full Text Available Gastric carcinoma is extremely rare in children representing only 0.05% of all gastrointestinal malignancies. Here, we report the first pediatric case of gastric cancer presenting with gastric outlet obstruction. Upper endoscopy revealed a markedly thickened antral mucosa occluding the pylorus and a clean base ulcer 1.5 cm × 2 cm at the lesser curvature of the stomach. The narrowed antrum and pylorus underwent balloon dilation, and biopsy from the antrum showed evidence of Helicobacter pylori gastritis. The biopsy taken from the edge of the gastric ulcer demonstrated signet-ring-cell type infiltrate consistent with gastric adenocarcinoma. At laparotomy, there were metastases to the liver, head of pancreas, and mesenteric lymph nodes. Therefore, the gastric carcinoma was deemed unresectable. The patient died few months after initiation of chemotherapy due to advanced malignancy. In conclusion, this case report underscores the possibility of gastric adenocarcinoma occurring in children and presenting with gastric outlet obstruction.

  15. Availability of healthier options in traditional and nontraditional rural fast-food outlets

    Directory of Open Access Journals (Sweden)

    McIntosh Alex

    2008-11-01

    Full Text Available Abstract Background Food prepared away from home has become increasingly popular to U.S. families, and may contribute to obesity. Sales have been dominated by fast food outlets, where meals are purchased for dining away from home or in the home. Although national chain affiliated fast-food outlets are considered the main source for fast food, fast foods are increasingly available in convenience stores and supermarkets/grocery stores. In rural areas, these nontraditional fast-food outlets may provide most of the opportunities for procurement of fast foods. Methods Using all traditional and nontraditio nal fast-food outlets identified in six counties in rural Texas, the type and number of regular and healthiermenu options were surveyed using on-site observation in all food venues that were primarily fast food, supermarket/grocery store, and convenience store and compared with 2005 Dietary Guidelines. Results Traditional fast-food outlets represented 84 (41% of the 205 opportunities for procurement of fast food; 109 (53.2% were convenience stores and 12 (5.8% supermarkets/grocery stores. Although a s imilar variety of regular breakfast and lunch/dinner entrées were available in traditional fast-food outlets and convenience stores, the variety of healthier breakfast and lunch/dinner entrées was significantly greater in fast food outlets. Compared with convenience stores, supermarkets/grocery stores provided a greater variety of regular and healthier entrées and lunch/dinner side dishes. Conclusion Convenience stores and supermarkets/grocery stores more than double the potential access to fast foods in this rural area than traditional fast-food outlets alone; however, traditional fast food outlets offer greater opportunity for healthier fast food options than convenience stores. A complete picture of fast food environment and the availability of healthier fast food options are essential to understand environmental influences on diet and health

  16. Albanian and UK Consumers’ Perceptions of Farmers’ Markets and Supermarkets as Outlets for Organic Food: An Exploratory Study

    Directory of Open Access Journals (Sweden)

    Athina-Evera Qendro

    2015-05-01

    Full Text Available The purpose of this paper is to elicit UK and Albanian consumers’ perceptions of food outlets in order to understand their views on supermarkets and farmers’ markets as outlets for organic food. A qualitative research methodology was chosen as the best way to get an in-depth understanding of how consumers of these two different countries understand and evaluate buying organic food from two different food outlets. This exploratory research is a first step to find out how and why organic food is being bought in supermarkets and farmers’ markets. The results show that respondents associated organic with vegetables and fruit, that taste good, are healthy, and are free of pesticides and hormones. The importance of motives varies between the outlets they prefer for buying organic food. An interesting finding is the fact that Albanian respondents refer to the farmers’ markets as the villagers’ market.

  17. Thermal Test in accordance with Mesh Size at Opening of the Inlets and Outlets of Concrete Storage Cask

    Energy Technology Data Exchange (ETDEWEB)

    Bang, K. S.; Yu, S. H.; Lee, J. C.; Choi, W. S. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The concrete storage cask must be designed to have heat removal capabilities with appropriate reliability. However, the thermal conductivity of concrete is not adequate for this purpose. The American Concrete Institute standard ACI-349 specifies a limit of 66 .deg. C for the normal operating temperature of concrete, except for the local areas, which may not exceed 93 .deg. C, and a short-term or accident temperature limit of no more than 177 .deg. C. Therefore, a passive heat removal system was designed to maintain the temperatures of the fuel-assembly cladding material and concrete storage cask components within these allowable limits. The passive heat-removal system consists of four inlets and four outlets, and their openings are covered by screens of mesh structure to prevent debris or wildlife from entering the ventilation ducts. Depending on its mesh size, each screen will have a different effect on the heat removal of the concrete storage cask. This paper discusses the experimental approach used in the present study to evaluate the heat removal performance under normal conditions in accordance with the mesh size of the screen installed at the opening of the inlets and outlets. The main results of the study are described below. The mesh size of the screen had an insignificant effect on the temperature rise of the canister surface and the over-pack surface.

  18. Evaporator Superheat Control With One Temperature Sensor Using Qualitative System Knowledge

    DEFF Research Database (Denmark)

    Vinther, Kasper; Hillerup Lyhne, Casper; Baasch Sørensen, Erik

    2012-01-01

    This paper proposes a novel method for superheat control using only a single temperature sensor at the outlet of the evaporator, while eliminating the need for a pressure sensor. An inner loop controls the outlet temperature and an outer control loop provides a reference set point, which is based...... filling of the evaporator, with only one temperature sensor. No a priori model knowledge was used and it is anticipated that the method is applicable on a wide variety of refrigeration systems....

  19. The impact of inlet angle and outlet angle of guide vane on pump in reversal based hydraulic turbine performance

    International Nuclear Information System (INIS)

    Shi, F X; Yang, J H; Wang, X H; Zhang, R H; Li, C E

    2012-01-01

    In this paper, in order to research the impact of inlet angle and outlet angle of guide vane on hydraulic turbine performance, a centrifugal pump in reversal is adopted as turbine. A numerical simulation method is adopted for researching outer performance and flow field of turbine. The results show: inlet angle has a crucial role to turbine, to the same flow, there is a noticeable decline for the efficiency and head of turbine with the inlet angle increases. At the best efficiency point(EFP),to a same inlet angle, when the inlet angle greater than inlet angle, velocity circulation in guide vane outlet decreases, which lead the efficiency of turbine to reduce, Contrarily, the efficiency rises. With the increase of inlet angle and outlet angle, the EFP moves to the big flow area and the uniformity of pressure distribution becomes worse. The paper indicates that the inlet angle and outlet angle have great impact on the turbine performance, and the best combination exists for the inlet angle and outlet angle of the guide vane.

  20. Power source with spark-safe outlet

    Energy Technology Data Exchange (ETDEWEB)

    Tsesarenko, N P; Alekhin, A V

    1982-01-01

    The invention refers to the technique of electrical monitoring and control in systems operating in a spark-safe medium (for example, in coal mines). A more accurate area of application is mobile objects with autonomous source of electricity (mine diesel locomotives, battery electric locomotives etc.). The purpose of the invention is to simplify and to improve the reliability of the planned device, and also to expand the area of application for conditions when it is powered from an autonomous generator of direct voltage. This goal is achieved because the power source with spark-safe outlet (the source contains a thyristor of advance disconnection, connected by anode to the delimiting throttle, one outlet of which is connected to the capacitor included between the controlling electrode and the anode of the thyristor, and the capacitor is connected through the resistor parallel to the outlet clamps of the source, while the thyristor of emergency protection connected parallel to the inlet clamps of the power source) is additionally equipped with a current sensor, hercon, transistor key (included in series in the power circuit) and optron, whose emitter is connected parallel to the current sensor connected in series to the inlet of the power source, while the receiver of the optron is connected in a circuit for controlling the thyristor of emergency protection. Hercon is built into the core of the delimiting throttle and is connected to the circuit for controlling the transistor key.

  1. The Role at Rehabilitation in Treatment of Thoracic Outlet Syndrome

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hosseinian

    2003-01-01

    Full Text Available Objective: Thoracic outlet syndrome is a complex disorder caused by neurovascular irritation in the region of the thoracic outlet. The syndrome have been said to be mainly due to anomalous structures in the thoracic outlet, treatment for thoracic outlet syndrome varies among different institutions, and there has not been any standard program. In general conservative and surgical treatment can be do if necessary. Materials & Methods: The rehabilitation program consists of exercise and physiotherapy and brace designed to hold the posture in which thoracic outlet is enlarged. Exercise program was designed simple enough to be performed in the daily living or during work after minimal training and isometric exercises of Serratus anterior, Levator Scapulae and Erector Spinae muscles to be performed in one posture: flexion and elevation of scapular girdle and correction position of upper-thoracic spine. During 7 years, 131 cases of (T.O.S. were evaluated that 26 cases (20% have operated and 84 cases (64% have treated with conservative treatment and 21 cases (16% have been candidate for surgery but they didn't accepted. Results: All of the cases have treated with conservative treatment for four months. 84 cases responded well and no further treatment was needed. 47 cases were not satisfied with. The outcome of their treatment, that 26 cases have operated and 21 cases have not accepted the operation and continued the conservative treatment, they have had pain and slightly disability. 23 cases of operated group responded well and they have resumed to work, one case has had neuropraxia for about one year. Conclusion: Most cases of thoracic outlet syndrome (T.O.S. can be treated conservatively. Surgically treatment is indicated only in cases severe enough to make them disable to work. It is better all the patients undergo conservative treatment for at least four months then will decided for surgical treatment.

  2. Measurement of heat and momentum eddy diffusivities in recirculating LMFBR outlet plenum flows

    International Nuclear Information System (INIS)

    Manno, V.P.; Golay, M.W.

    1978-06-01

    An optical technique has been developed for the measurement of the eddy diffusivity of heat in a transparent flowing medium. The method uses a combination of two established measurement tools: a Mach-Zehnder interferometer for the monitoring of turbulently fluctuating temperature and a Laser Doppler Anemometer (LDA) for the measurement of turbulent velocity fluctuations. The technique is applied to the investigation of flow fields characteristic of the LMFBR outlet plenum. The study is accomplished using air as the working fluid in a small scale Plexiglas test section. Lows are introduced into both the 1 / 15 scale FFTF outlet plenum and the 3 / 80 scale CRBR geometry plenum at inlet Reynolds numbers of 22,000. Measurements of the eddy diffusivity of heat and the eddy diffusivity of momentum are performed at a total of 11 measurement stations. Significant differences of the turbulence parameters are found between the two geometries, and the higher chimney structure of the CRBR case is found to be the major cause of the distinction. Spectral intensity studies of the fluctuating electronic analog signals of velocity and temperature are also performed. Error analysis of the overall technique indicates an experimental error of 10% in the determination of the eddy diffusivity of heat and 6% in the evaluation of turbulent momentum viscosity. In general it is seen that the turbulence in the cases observed is not isotropic, and use of isotropic turbulent heat and momentum diffusivities in transport modelling would not be a valid procedure

  3. Female outlet obstruction constipation: assessment with MR defecography

    International Nuclear Information System (INIS)

    Li Min; Jiang Tao; Yang Xinqing; Peng Peng; Wang Wenchuan

    2010-01-01

    Objective: Using MR defecography to assess the morphological and functional anorectal anomalies related to female outlet obstruction constipation, and evaluate the joint disease of' anterior and mid pelvic. Methods: One hundred and seven female patients, aged 20 to 84 years (average, 55 years), were diagnosed as outlet obstruction constipation based on clinical symptoms and signs. They all received MR defecography in our institution. The high compliance homemade balloon was inserted into rectum to simulate stool. Then relevant measurements were obtained during rest, squeezing and straining, respectively. Results: In all the 107 cases, 70 (65.4%) presented rectocele on dynamic MRI; 28 (26.2%) presented anismus; 60 (56.1%) presented cystocele; 59 presented vaginal or cervical prolapse(55.1%); and, 54 (50.5%) presented descending perineum. In 85 females (79.4%) multiple disorders were detected, involving more than one pelvic compartment. Conclusion: MR defecography allowed to accurately evaluate the morphological and functional anorectal anomalies related to female outlet obstruction constipation, and the joint disease of anterior and mid pelvic. (authors)

  4. Flue gas moisture capacity calculation at the outlet of the condensation heat recovery unit

    Directory of Open Access Journals (Sweden)

    Galashov Nikolay

    2017-01-01

    Full Text Available As a result, study equation has been obtained which determine the flue gas moisture capacity at the outlet of the condensation heat recovery unit with an error of less than 1%. It possible to at the temperature of the flue gas below the dew point and the known air-fuel ratio efficient. The equation can be used to calculate plants operating on products of gas combustion without Use of tables and programs for calculating the water-vapor saturation pressure.

  5. Availability of healthier options in traditional and nontraditional rural fast-food outlets

    OpenAIRE

    Creel, Jennifer S; Sharkey, Joseph R; McIntosh, Alex; Anding, Jenna; Huber, J Charles

    2008-01-01

    Abstract Background Food prepared away from home has become increasingly popular to U.S. families, and may contribute to obesity. Sales have been dominated by fast food outlets, where meals are purchased for dining away from home or in the home. Although national chain affiliated fast-food outlets are considered the main source for fast food, fast foods are increasingly available in convenience stores and supermarkets/grocery stores. In rural areas, these nontraditional fast-food outlets may ...

  6. Numerical Research about Influence of Blade Outlet Angle on Flow-Induced Noise and Vibration for Centrifugal Pump

    Directory of Open Access Journals (Sweden)

    Ailing Yang

    2014-03-01

    Full Text Available A hybrid numerical method was used to calculate the flow-induced noise and vibration of the centrifugal pump in the paper. The unsteady flows inside the centrifugal pumps with different blade outlet angles were simulated firstly. The unsteady pressure on the inner surface of the volute and the unsteady force applied on the impeller were analyzed. Then the vibration of the volute and sound field were calculated based on an acoustic-vibro-coupling method. The results show that the pump head has increased 7% while the hydraulic efficiency decreased 11.75% as blade outlet angles increased from 18° to 39°. The amplitude of pressure fluctuation at the first blade passing frequency has decreased but increased at the second-order blade passing frequency as the angle growing. The total fluctuation power near volute tongue goes up about 12% every 3° increment of blade outlet angle. The results also show that vibrating-velocity of the volute at second-order blade passing frequency is much higher than at other frequencies, and the velocity increases rapidly as blade outlet angle varies from 18° to 39°. At the same time, the sound pressure level outside the pump has increased about 8.6 dB when the angle increased from 18° to 39°.

  7. Antral hyperplastic polyp causing intermittent gastric outlet obstruction: Case report

    Directory of Open Access Journals (Sweden)

    Kurtkaya-Yapicier Ozlem

    2003-06-01

    Full Text Available Abstract Background Hyperplastic polyps are the most common polypoid lesions of the stomach. Rarely, they cause gastric outlet obstruction by prolapsing through the pyloric channel, when they arise in the prepyloric antrum. Case presentation A 62-year-old woman presented with intermittent nausea and vomiting of 4 months duration. Upper gastrointestinal endoscopy revealed a 30 mm prepyloric sessile polyp causing intermittent gastric outlet obstruction. Following submucosal injection of diluted adrenaline solution, the polyp was removed with a snare. Multiple biopsies were taken from the greater curvature of the antrum and the corpus. Rapid urease test for Helicobacter pylori yielded a negative result. Histopathologic examination showed a hyperplastic polyp without any evidence of malignancy. Biopsies of the antrum and the corpus revealed gastritis with neither atrophic changes nor Helicobacter pylori infection. Follow-up endoscopy after a 12-week course of proton pomp inhibitor therapy showed a complete healing without any remnant tissue at the polypectomy site. The patient has been symptom-free during 8 months of follow-up. Conclusions Symptomatic gastric polyps should be removed preferentially when they are detected at the initial diagnostic endoscopy. Polypectomy not only provides tissue to determine the exact histopathologic type of the polyp, but also achieves radical treatment.

  8. Impact of remodeling and rehabilitation of irrigation outlets on water distribution of a canal in Punjab, Pakistan

    International Nuclear Information System (INIS)

    Bodla, H.; Latif, M.

    2009-01-01

    The study was undertaken to investigate water distribution along a distributary canal located in the southern part of the Punjab Province. It is a large size distributary having 353 cusecs of authorized discharge. This distributary was subjected to a series of problems including but not limited to (i) withdrawal of water by illegal means, (ii) design and construction flaws in the outlets, (iii) improper selection of the type of outlets and many others. The outlets were intentionally designed wrongly by using fictitious hydraulics data to provide undue benefits to the irrigators. During construction, setting of the outlets was also intentionally fixed at lower level than the designed. Investigations were carried out to evaluate hydraulic performance of all the outlets of the channel. Based on the observed data capacity statements of all the outlets were revised. The outlets were redesigned on the basis of actual hydraulic data of each outlet. Most of the non-modular outlets (Pipe and Scratchley) were converted to semi-modular outlets (OFRB and APM). With implementation of new and modified design of the outlets at the site, equity of water distribution has been improved. The results revealed that design of the outlets had a significant impact on equitable distribution of water along the distribution. (author)

  9. Benign Strictures of the Esophagus and Gastric Outlet: Interventional Management

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hyoung; Shin, Ji Hoon; Song, Ho Young [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2010-10-15

    Benign strictures of the esophagus and gastric outlet are difficult to manage conservatively and they usually require intervention to relieve dysphagia or to treat the stricture-related complications. In this article, authors review the non-surgical options that are used to treat benign strictures of the esophagus and gastric outlet, including balloon dilation, temporary stent placement, intralesional steroid injection and incisional therapy

  10. Using public health and community partnerships to reduce density of alcohol outlets.

    Science.gov (United States)

    Jernigan, David H; Sparks, Michael; Yang, Evelyn; Schwartz, Randy

    2013-04-11

    Excessive alcohol use causes approximately 80,000 deaths in the United States each year. The Guide to Community Preventive Services recommends reducing the density of alcohol outlets - the number of physical locations in which alcoholic beverages are available for purchase either per area or per population - through the use of regulatory authority as an effective strategy for reducing excessive alcohol consumption and related harms. We briefly review the research on density of alcohol outlets and public health and describe the powers localities have to influence alcohol outlet density. We summarize Regulating Alcohol Outlet Density: An Action Guide, which describes steps that local communities can take to reduce outlet density and the key competencies and resources of state and local health departments. These include expertise in public health surveillance and evaluation methods, identification and tracking of outcome measures, geographic information systems (GIS) mapping, community planning and development of multisector efforts, and education of community leaders and policy makers. We illustrate the potential for partnerships between public health agencies and local communities by presenting a contemporary case study from Omaha, Nebraska. Public health agencies have a vital and necessary role to play in efforts to reduce alcohol outlet density. They are often unaware of the potential of this strategy and have strong potential partners in the thousands of community coalitions nationwide that are focused on reducing alcohol-related problems.

  11. Transvaginal Mesh and Transanal Resection to Treat Outlet Obstruction Constipation Caused by Rectocele.

    Science.gov (United States)

    Shi, Yang; Yu, Yongjun; Zhang, Xipeng; Li, Yuwei

    2017-02-01

    BACKGROUND The aim of this study was to evaluate the curative effect of transvaginal mesh repair (TVMR) and stapled transanal rectal resection (STARR) in treating outlet obstruction constipation caused by rectocele. MATERIAL AND METHODS Patients who had outlet obstruction constipation caused by rectocele were retrospectively analyzed and 39 patients were enrolled the study. Patients were assigned to either the TVMR or STARR group. Postoperative factors such as complications, pain, recurrence rate, and operative time were compared between the 2 groups. RESULTS Total effective rate was 100% in both groups. No long-term chronic pain occurred and discomfort rate of tenesmus was higher in the STARR group than in the TVMR group. Postoperative defecography showed that the rectocele depth was significantly reduced, and the prolapse of the rectal mucosa and the lower rectal capacity was also decreased. Four cases had mesh exposure in the TVMR group and 2 cases in the STARR group had anastomotic bleeding after the surgery. CONCLUSIONS For outlet obstruction constipation caused by rectocele, TVMR and STARR both obtained satisfactory results. Although TVMR is complex with longer operative time and hospitalization period, its long-term effect is better than that of STARR.

  12. Transvaginal Mesh and Transanal Resection to Treat Outlet Obstruction Constipation Caused by Rectocele

    Science.gov (United States)

    Shi, Yang; Yu, Yongjun; Zhang, Xipeng; Li, Yuwei

    2017-01-01

    Background The aim of this study was to evaluate the curative effect of transvaginal mesh repair (TVMR) and stapled transanal rectal resection (STARR) in treating outlet obstruction constipation caused by rectocele. Material/Methods Patients who had outlet obstruction constipation caused by rectocele were retrospectively analyzed and 39 patients were enrolled the study. Patients were assigned to either the TVMR or STARR group. Postoperative factors such as complications, pain, recurrence rate, and operative time were compared between the 2 groups. Results Total effective rate was 100% in both groups. No long-term chronic pain occurred and discomfort rate of tenesmus was higher in the STARR group than in the TVMR group. Postoperative defecography showed that the rectocele depth was significantly reduced, and the prolapse of the rectal mucosa and the lower rectal capacity was also decreased. Four cases had mesh exposure in the TVMR group and 2 cases in the STARR group had anastomotic bleeding after the surgery. Conclusions For outlet obstruction constipation caused by rectocele, TVMR and STARR both obtained satisfactory results. Although TVMR is complex with longer operative time and hospitalization period, its long-term effect is better than that of STARR. PMID:28146137

  13. Radiological findings of gastric adenomyoma in a neonate presenting with gastric outlet obstruction.

    Science.gov (United States)

    Rhim, Jung Hyo; Kim, Woo Sun; Choi, Young Hun; Cheon, Jung-Eun; Park, Sung Hye

    2013-03-01

    Gastric adenomyoma is a rare tumour-like lesion composed of glandular components and smooth muscle bundles. We report a case of gastric adenomyoma in a 1-week-old neonate who presented with gastric outlet obstruction. To the best of our knowledge, this is the youngest child reported with gastric adenomyoma and a unique case demonstrating radiological findings of gastric adenomyoma in a young infant. At US, the lesion was seen as an asymmetrical mass-like wall-thickening of the pylorus. Upper gastrointestinal series showed findings similar to those seen in a case of hypertrophic pyloric stenosis. We suggest that gastric adenomyoma should be included in the causes of gastric outlet obstruction in neonates even though it is rare in young children.

  14. Validation of presence of supermarkets and fast-food outlets in Copenhagen

    DEFF Research Database (Denmark)

    Svastisalee, Chalida M; Holstein, Bjørn E; Due, Pernille

    2012-01-01

    We examined the quality of food outlet addresses provided by secondary sources and determined whether they could be physically located in the field.......We examined the quality of food outlet addresses provided by secondary sources and determined whether they could be physically located in the field....

  15. Beyond Supermarkets: Food Outlet Location Selection in Four U.S. Cities Over Time.

    Science.gov (United States)

    Rummo, Pasquale E; Guilkey, David K; Ng, Shu Wen; Popkin, Barry M; Evenson, Kelly R; Gordon-Larsen, Penny

    2017-03-01

    Understanding what influences where food outlets locate is important for mitigating disparities in access to healthy food outlets. However, few studies have examined how neighborhood characteristics influence the neighborhood food environment over time, and whether these relationships differ by neighborhood-level income. Neighborhood-level data from four U.S. cities (Birmingham, AL; Chicago, IL; Minneapolis, MN; Oakland, CA) from 1986, 1993, 1996, 2001, 2006, and 2011 were used with two-step econometric models to estimate longitudinal associations between neighborhood-level characteristics (z-scores) and the log-transformed count/km 2 (density) of food outlets within real estate-derived neighborhoods. Associations were examined with lagged neighborhood-level sociodemographics and lagged density of food outlets, with interaction terms for neighborhood-level income. Data were analyzed in 2016. Neighborhood-level income at earlier years was negatively associated with the current density of convenience stores (β= -0.27, 95% CI= -0.16, -0.38, prestaurant density in low-income neighborhoods (10th percentile of income: β= -0.17, 95% CI= -0.34, -0.002, p=0.05), and the density of smaller grocery stores across all income levels (β= -0.27, 95% CI= -0.45, -0.09, p=0.003). There was a lack of policy-relevant associations between the pre-existing food environment and the current density of food outlet types, including supermarkets. Socioeconomically disadvantaged and minority populations may attract "unhealthy" food outlets over time. To support equal access to healthy food outlets, the availability of "less healthy" food outlets types may be relatively more important than the potential lack of supermarkets or full-service restaurants. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  16. Data on microbial and physiochemical characteristics of inlet and outlet water from household water treatment devices in Rasht, Iran.

    Science.gov (United States)

    Naghipour, Dariush; Ashrafi, Seyed Davoud; Mojtahedi, Ali; Vatandoost, Masoud; Hosseinzadeh, Loghman; Roohbakhsh, Esmail

    2018-02-01

    In this research, we measured various parameters related to drinking water quality include turbidity, temperature, pH, EC, TDS, Alkalinity, fecal and total coliform, heterotrophic plate count (HPC), free chlorine, Mn, Ca, Mg, Fe, Na, Cl - , F - , HCO 3 , in the inlet and outlet of household water treatment devices according to the standard methods for the examination of water and wastewater (W.E. Federation and Association and A.P.H., 2005) [1]. Sixty four inlet and outlet water samples were taken from thirty two household water treatment devices from eight different residential blocks in Golsar town of Rasht, Iran. The data obtained from experiments were analyzed using the software Special Package for Social Sciences (SPSS 24) and MS-Excel.

  17. Spatial accessibility to physical activity facilities and to food outlets and overweight in French youth.

    Science.gov (United States)

    Casey, R; Chaix, B; Weber, C; Schweitzer, B; Charreire, H; Salze, P; Badariotti, D; Banos, A; Oppert, J-M; Simon, C

    2012-07-01

    Some characteristics of the built environment have been associated with obesity in youth. Our aim was to determine whether individual and environmental socio-economic characteristics modulate the relation between youth overweight and spatial accessibility to physical activity (PA) facilities and to food outlets. Cross-sectional study. 3293 students, aged 12 ± 0.6 years, randomly selected from eastern France middle schools. Using geographical information systems (GIS), spatial accessibility to PA facilities (urban and nature) was assessed using the distance to PA facilities at the municipality level; spatial accessibility to food outlets (general food outlets, bakeries and fast-food outlets) was calculated at individual level using the student home address and the food outlets addresses. Relations of weight status with spatial accessibility to PA facilities and to food outlets were analysed using mixed logistic models, testing potential direct and interaction effects of individual and environmental socio-economic characteristics. Individual socio-economic status modulated the relation between spatial accessibility to PA facilities and to general food outlets and overweight. The likelihood of being overweight was higher when spatial accessibility to urban PA facilities and to general food outlets was low, but in children of blue-collar-workers only. The odds ratio (OR) (95% confidence interval) for being overweight of blue-collar-workers children compared with non-blue-collar-workers children was 1.76 (1.25-2.49) when spatial accessibility to urban PA facilities was low. This OR was 1.86 (1.20-2.86) when spatial accessibility to general food outlets was low. There was no significant relationship of overweight with either nature PA facilities or other food outlets (bakeries and fast-food outlets). These results indicate that disparities in spatial accessibility to PA facilities and to general food outlets may amplify the risk of overweight in socio

  18. Epigastric heteropagus associated with an omphalocele and double outlet right ventricle

    Directory of Open Access Journals (Sweden)

    Tatsuma Sakaguchi

    2015-10-01

    Full Text Available Incomplete or asymmetrical conjoined twins are extremely rare congenital anomalies. We report a case of epigastric heteropagus associated with an omphalocele and double outlet right ventricle. The cystic legion of the epigastrium was detected in our patient by an ultrasound scan at 28 weeks' gestation. He was born at 37 weeks' gestation by scheduled caesarean section. A parasite with an incomplete head and lower limb was attached to the epigastrium of the autosite. Surgical separation of the parasite and silo placement for an omphalocele was successfully performed on the 4th day of life. He underwent secondary surgical closure of the omphalocele on the 10th day. For treatment of the cardiac anomaly, he underwent an operation of Blalock–Taussig shunt because of pulmonary artery stenosis at the age of 3 months and correction of double outlet right ventricle at the age of 10 months. At the 20-month follow-up, he was alive and showed a normal growth pattern.

  19. The prospects of making small retail outlets in the Townships aggressively competitive

    Directory of Open Access Journals (Sweden)

    Malefane Johannes Lebusa

    2013-12-01

    Full Text Available Historically, township Small Retail Outlets were mostly established for survival and operated under a generally closed market system where the competition was not very strong. However, with the advent of democracy many people lost their formal income through retrenchments and out of desperation, many of these people opened Small Retail Outlets thus most of the existing and new entrants into the township market were unskilled or semiskilled labourers with little or no formal skills in business or entrepreneurship. Such efforts were rarely guided by any specific and informed strategy of identifying and exploiting a gap in the market. With the consolidation of the free market system under democracy, big brand businesses such as Shoprite Checkers and Small Retail Outlets of foreign nationals with different strategies entered and competed in this township market. With fewer formal skills in business and entrepreneurship, the owners of the Small Retail Outlets struggled to compete and thrive under these relatively new economic conditions. Given this situation, I conducted semi-structured interviews with fifteen of these traditional Small Retail Outlets to find out and better understand the challenges they face and the skills that might be needed to aggressively compete in this space. Based on these findings and understandings, I further examined these issues and suggest infusions of specific entrepreneurship skills that could develop their aggressive competitiveness. Keywords: entrepreneurship, competitiveness, small retail outlets, shopping complexes, innovation

  20. Velocity profile of water vapor inside a cavity with two axial inlets and two outlets

    Science.gov (United States)

    Guadarrama-Cetina, José; Ruiz Chavarría, Gerardo

    2014-03-01

    To study the dynamics of Breath Figure phenomenon, a control of both the rate of flow and temperature of water vapor is required. The experimental setup widely used is a non hermetically closed chamber with cylindrical geometry and axial inlets and outlets. In this work we present measurements in a cylindrical chamber with diameter 10 cm and 1.5 cm height, keeping a constant temperature (10 °C). We are focused in the velocity field when a gradient of the temperatures is produced between the base plate and the vapor. With a flux of water vapor of 250 mil/min at room temperature (21 °C), the Reynolds number measured in one inlet is 755. Otherwise, the temperatures of water vapor varies from 21 to 40 °C. The velocity profile is obtained by hot wire anemometry. We identify the stagnations and the possibly instabilities regions for an empty plate and with a well defined shape obstacle as a fashion sample. Facultad de Ciencias, UNAM.

  1. The association of alcohol outlet density with illegal underage adolescent purchasing of alcohol.

    Science.gov (United States)

    Rowland, Bosco; Toumbourou, John W; Livingston, Michael

    2015-02-01

    Although previous studies have suggested that greater community densities of alcohol sales outlets are associated with greater alcohol use and problems, the mechanisms are unclear. The present study examined whether density was associated with increased purchasing of alcohol by adolescents younger than the legal purchase age of 18 in Australia. The number of alcohol outlets per 10,000 population was identified within geographic regions in Victoria, Australia. A state-representative student survey (N = 10,143) identified adolescent reports of purchasing alcohol, and multilevel modeling was then used to predict the effects for different densities of outlet types (packaged, club, on-premise, general, and overall). Each extra sales outlet per 10,000 population was associated with a significant increase in the risk of underage adolescent purchasing. The strongest effect was for club density (odds ratio = 1.22) and packaged (takeaway) outlet density (odds ratio = 1.12). Males, older children, smokers, and those with substance-using friends were more likely to purchase alcohol. One mechanism by which alcohol sales outlet density may influence population rates of alcohol use and related problems is through increasing the illegal underage purchasing of alcohol. Copyright © 2015 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  2. Discussion on Boiler Efficiency Correction Method with Low Temperature Economizer-Air Heater System

    Science.gov (United States)

    Ke, Liu; Xing-sen, Yang; Fan-jun, Hou; Zhi-hong, Hu

    2017-05-01

    This paper pointed out that it is wrong to take the outlet flue gas temperature of low temperature economizer as exhaust gas temperature in boiler efficiency calculation based on GB10184-1988. What’s more, this paper proposed a new correction method, which decomposed low temperature economizer-air heater system into two hypothetical parts of air preheater and pre condensed water heater and take the outlet equivalent gas temperature of air preheater as exhaust gas temperature in boiler efficiency calculation. This method makes the boiler efficiency calculation more concise, with no air heater correction. It has a positive reference value to deal with this kind of problem correctly.

  3. 16 CFR Appendix B to Part 436 - Sample Item 20(1) Table-Systemwide Outlet Summary

    Science.gov (United States)

    2010-01-01

    ... DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. B Appendix B to Part 436—Sample... 1Outlet Type Column 2Year Column 3Outlets at the Start of the Year Column 4Outlets at the End of the Year...

  4. Methodological Approaches to Locating Outlets of the Franchise Retail Network

    OpenAIRE

    Grygorenko Tetyana M.

    2016-01-01

    Methodical approaches to selecting strategic areas of managing the future location of franchise retail network outlets are presented. The main stages in the assessment of strategic areas of managing the future location of franchise retail network outlets have been determined and the evaluation criteria have been suggested. Since such selection requires consideration of a variety of indicators and directions of the assessment, the author proposes a scale of evaluation, which ...

  5. Outlet strut fracture and leaflet escape of Bjork-Shiley convexo-concave valve.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Hideo; Sakoda, Naoya; Hattori, Shigeru; Kawabata, Takuya; Saiki, Munehiro; Fujita, Yasufumi; Yunoki, Keiji; Hisamochi, Kunikazu; Mine, Yoshinari

    2017-06-01

    Prosthetic valve fracture is a serious complication and may arise in patient post-valve replacement. We experienced an outlet strut fracture and leaflet escape of a Bjork-Shiley convexo-concave valve. We performed an emergency redo mitral valve replacement and successfully retrieved the fractured strut and escaped leaflet from superficial femoral artery and the abdominal aorta. The patient showed an uneventful postoperative recovery.

  6. Automated Temperature Control with Adjusting Outlet Valve of Fuel in the Process of Cooking Palm Sugar

    Science.gov (United States)

    Aripin, H.; Hiron, Nurul; Priatna, Edvin; Busaeri, Nundang; Andang, Asep; Suhartono; Sabchevski, Svilen

    2018-04-01

    In this paper, a real-time temperature control system for coconut sugar cooking is presented. It is based on a thermocouple temperature sensor. The temperature in the closed evaporator is used as a control variable of the DC servo control system for opening and closing of a valve embedded in a gas burner. The output power level, which is necessary in order to reach the target temperature is controlled by the microcontroller ATMega328P. A circuit module for control of the valve and temperature sensors as well as software for data acquisition have been implemented. The test results show that the system properly stabilizes the temperature in the closed evaporator for coconut sugar cooking in the range from room temperature to 110°C. A set point can be reached and held with an accuracy of ±0.75°C at a temperature of 110°C for 60 minutes.

  7. Validation of commercial business lists as a proxy for licensed alcohol outlets.

    Science.gov (United States)

    Carlos, Heather A; Gabrielli, Joy; Sargent, James D

    2017-05-19

    Studies of retail alcohol outlets are restricted to regions due to lack of U.S. national data. Commercial business lists (BL) offer a possible solution, but no data exists to determine if BLs could serve as an adequate proxy for license data. This paper compares geospatial measures of alcohol outlets derived from a commercial BL with license data for a large US state. We validated BL data as a measure of off-premise alcohol outlet density and proximity compared to license data for 5528 randomly selected California residential addresses. We calculated three proximity measures (Euclidean distance, road network travel time and distance) and two density measures (kernel density estimation and the count within a 2-mile radius) for each dataset. The data was acquired in 2015 and processed and analyzed in 2015 and 2016. Correlations and reliabilities between density (correlation 0.98; Cronbach's α 0.97-0.99) and proximity (correlations 0.77-0.86; α 0.87-0.92) measures were high. For proximity, BL data matched license in 55-57% of addresses, overstated distance in 19%, and understated in 24-26%. BL data can serve as a reliable proxy for licensed alcohol outlets, thus extending the work that can be performed in studies on associations between retail alcohol outlets and drinking outcomes.

  8. The “School Foodshed”: schools and fast-food outlets in a London borough

    OpenAIRE

    Caraher, M.; Lloyd, S.; Madelin, T.

    2014-01-01

    Purpose – The purpose of this paper is to explore the location of fast-food outlets around secondary schools and the influence of fast-food availability on the food choices of school children in an inner-London borough. \\ud \\ud Design/methodology/approach – A number of methods including: mapping of outlets relative to schools; sampling food; gathering data on secondary school food policies; observing food behaviour in fast food outlets and focus groups with young people. Findings were fed bac...

  9. Proximity to Fast-Food Outlets and Supermarkets as Predictors of Fast-Food Dining Frequency.

    Science.gov (United States)

    Athens, Jessica K; Duncan, Dustin T; Elbel, Brian

    2016-08-01

    This study used cross-sectional data to test the independent relationship of proximity to chain fast-food outlets and proximity to full-service supermarkets on the frequency of mealtime dining at fast-food outlets in two major urban areas, using three approaches to define access. Interactions between presence of a supermarket and presence of fast-food outlets as predictors of fast-food dining were also tested. Residential intersections for respondents in point-of-purchase and random-digit-dial telephone surveys of adults in Philadelphia, PA, and Baltimore, MD, were geocoded. The count of fast-food outlets and supermarkets within quarter-mile, half-mile, and 1-mile street network buffers around each respondent's intersection was calculated, as well as distance to the nearest fast-food outlet and supermarket. These variables were regressed on weekly fast-food dining frequency to determine whether proximity to fast food and supermarkets had independent and joint effects on fast-food dining. The effect of access to supermarkets and chain fast-food outlets varied by study population. Among telephone survey respondents, supermarket access was the only significant predictor of fast-food dining frequency. Point-of-purchase respondents were generally unaffected by proximity to either supermarkets or fast-food outlets. However, ≥1 fast-food outlet within a 1-mile buffer was an independent predictor of consuming more fast-food meals among point-of-purchase respondents. At the quarter-mile distance, ≥1 supermarket was predictive of fewer fast-food meals. Supermarket access was associated with less fast-food dining among telephone respondents, whereas access to fast-food outlets were associated with more fast-food visits among survey respondents identified at point-of-purchase. This study adds to the existing literature on geographic determinants of fast-food dining behavior among urban adults in the general population and those who regularly consume fast food. Copyright

  10. Endoscopic stenting versus operative gastrojejunostomy for malignant gastric outlet obstruction.

    Science.gov (United States)

    Chandrasegaram, Manju D; Eslick, Guy D; Mansfield, Clare O; Liem, Han; Richardson, Mark; Ahmed, Sulman; Cox, Michael R

    2012-02-01

    Malignant gastric outlet obstruction represents a terminal stage in pancreatic cancer. Between 5% and 25% of patients with pancreatic cancer ultimately experience malignant gastric outlet obstruction. The aim in palliating patients with malignant gastric outlet obstruction is to reestablish an oral intake by restoring gastrointestinal continuity. This ultimately improves their quality of life in the advanced stages of cancer. The main drawback to operative bypass is the high incidence of delayed gastric emptying, particularly in this group of patients with symptomatic obstruction. This study aimed to compare surgical gastrojejunostomy and endoscopic stenting in palliation of malignant gastric outlet obstruction, acknowledging the diversity and heterogeneity of patients with this presentation. This retrospective study investigated patients treated for malignant gastric outlet obstruction from December 1998 to November 2008 at Nepean Hospital, Sydney, Australia. Endoscopic duodenal stenting was performed under fluoroscopic guidance for placement of the stent. The operative patients underwent open surgical gastrojejunostomy. The outcomes assessed included time to diet, hospital length of stay (LOS), biliary drainage procedures, morbidity, and mortality. Of the 45 participants in this study, 26 underwent duodenal stenting and 19 had operative bypass. Comparing the stenting and operative patients, the median time to fluid intake was respectively 0 vs. 7 days (P < 0.001), and the time to intake of solids was 2 vs. 9 days (P = 0.004). The median total LOS was shorter in the stenting group (11 vs. 25 days; P < 0.001), as was the median postprocedure LOS (5 vs. 10 days; P = 0.07). Endoscopic stenting is preferable to operative gastrojejunostomy in terms of shorter LOS, faster return to fluids and solids, and reduced morbidity and in-hospital mortality for patients with a limited life span.

  11. Contamination of faecal coliforms in ice cubes sampled from food outlets in Kubang Kerian, Kelantan.

    Science.gov (United States)

    Noor Izani, N J; Zulaikha, A R; Mohamad Noor, M R; Amri, M A; Mahat, N A

    2012-03-01

    The use of ice cubes in beverages is common among patrons of food outlets in Malaysia although its safety for human consumption remains unclear. Hence, this study was designed to determine the presence of faecal coliforms and several useful water physicochemical parameters viz. free residual chlorine concentration, turbidity and pH in ice cubes from 30 randomly selected food outlets in Kubang Kerian, Kelantan. Faecal coliforms were found in ice cubes in 16 (53%) food outlets ranging between 1 CFU/100mL to >50 CFU/ 100mL, while in the remaining 14 (47%) food outlets, in samples of tap water as well as in commercially bottled drinking water, faecal coliforms were not detected. The highest faecal coliform counts of >50 CFU/100mL were observed in 3 (10%) food outlets followed by 11-50 CFU/100mL and 1-10 CFU/100mL in 7 (23%) and 6 (20%) food outlets, respectively. All samples recorded low free residual chlorine concentration (contamination by faecal coliforms was not detected in 47% of the samples, tap water and commercially bottled drinking water, it was concluded that (1) contamination by faecal coliforms may occur due to improper handling of ice cubes at the food outlets or (2) they may not be the water sources used for making ice cubes. Since low free residual chlorine concentrations were observed (food outlets, including that of ice cube is crucial in ensuring better food and water for human consumption.

  12. CFD Study of Industrial FCC Risers: The Effect of Outlet Configurations on Hydrodynamics and Reactions

    Directory of Open Access Journals (Sweden)

    Gabriela C. Lopes

    2012-01-01

    Full Text Available Fluid catalytic cracking (FCC riser reactors have complex hydrodynamics, which depend not only on operating conditions, feedstock quality, and catalyst particles characteristics, but also on the geometric configurations of the reactor. This paper presents a numerical study of the influence of different riser outlet designs on the dynamic of the flow and reactor efficiency. A three-dimensional, three-phase flow model and a four-lump kinetic scheme were used to predict the performance of the reactor. The phenomenon of vaporization of the liquid oil droplets was also analyzed. Results showed that small changes in the outlet configuration had a significant effect on the flow patterns and consequently, on the reaction yields.

  13. Parallel segmented outlet flow high performance liquid chromatography with multiplexed detection

    International Nuclear Information System (INIS)

    Camenzuli, Michelle; Terry, Jessica M.; Shalliker, R. Andrew; Conlan, Xavier A.; Barnett, Neil W.; Francis, Paul S.

    2013-01-01

    Graphical abstract: -- Highlights: •Multiplexed detection for liquid chromatography. •‘Parallel segmented outlet flow’ distributes inner and outer portions of the analyte zone. •Three detectors were used simultaneously for the determination of opiate alkaloids. -- Abstract: We describe a new approach to multiplex detection for HPLC, exploiting parallel segmented outlet flow – a new column technology that provides pressure-regulated control of eluate flow through multiple outlet channels, which minimises the additional dead volume associated with conventional post-column flow splitting. Using three detectors: one UV-absorbance and two chemiluminescence systems (tris(2,2′-bipyridine)ruthenium(III) and permanganate), we examine the relative responses for six opium poppy (Papaver somniferum) alkaloids under conventional and multiplexed conditions, where approximately 30% of the eluate was distributed to each detector and the remaining solution directed to a collection vessel. The parallel segmented outlet flow mode of operation offers advantages in terms of solvent consumption, waste generation, total analysis time and solute band volume when applying multiple detectors to HPLC, but the manner in which each detection system is influenced by changes in solute concentration and solution flow rates must be carefully considered

  14. Parallel segmented outlet flow high performance liquid chromatography with multiplexed detection

    Energy Technology Data Exchange (ETDEWEB)

    Camenzuli, Michelle [Australian Centre for Research on Separation Science (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), Sydney, NSW (Australia); Terry, Jessica M. [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia); Shalliker, R. Andrew, E-mail: r.shalliker@uws.edu.au [Australian Centre for Research on Separation Science (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), Sydney, NSW (Australia); Conlan, Xavier A.; Barnett, Neil W. [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia); Francis, Paul S., E-mail: paul.francis@deakin.edu.au [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia)

    2013-11-25

    Graphical abstract: -- Highlights: •Multiplexed detection for liquid chromatography. •‘Parallel segmented outlet flow’ distributes inner and outer portions of the analyte zone. •Three detectors were used simultaneously for the determination of opiate alkaloids. -- Abstract: We describe a new approach to multiplex detection for HPLC, exploiting parallel segmented outlet flow – a new column technology that provides pressure-regulated control of eluate flow through multiple outlet channels, which minimises the additional dead volume associated with conventional post-column flow splitting. Using three detectors: one UV-absorbance and two chemiluminescence systems (tris(2,2′-bipyridine)ruthenium(III) and permanganate), we examine the relative responses for six opium poppy (Papaver somniferum) alkaloids under conventional and multiplexed conditions, where approximately 30% of the eluate was distributed to each detector and the remaining solution directed to a collection vessel. The parallel segmented outlet flow mode of operation offers advantages in terms of solvent consumption, waste generation, total analysis time and solute band volume when applying multiple detectors to HPLC, but the manner in which each detection system is influenced by changes in solute concentration and solution flow rates must be carefully considered.

  15. Tobacco outlet density and tobacco knowledge, beliefs, purchasing behaviours and price among adolescents in Scotland.

    Science.gov (United States)

    Tunstall, Helena; Shortt, Niamh K; Niedzwiedz, Claire L; Richardson, Elizabeth A; Mitchell, Richard J; Pearce, Jamie R

    2018-06-01

    Despite long-term falls in global adult smoking prevalence and over 50 years of tobacco control policies, adolescent smoking persists. Research suggests greater densities of tobacco retail outlets in residential neighbourhoods are associated with higher adolescent smoking rates. Policies to reduce retail outlets have therefore been identified by public health researchers as a potential 'new frontier' in tobacco control. Better understanding of the pathways linking density of tobacco retailers and smoking behaviour could support these policies. In this study we use path analysis to assess how outlet density in the home environment is related to adolescent tobacco knowledge, beliefs, retail purchases and price in Scotland. We assessed 22,049 13 and 15 year old respondents to the nationally representative cross-sectional 2010 Scottish School Adolescent Lifestyle and Substance Use Survey. Outlet density was based on Scottish Tobacco Retailers Register, 2012, data. A spatially-weighted Kernel Density Estimation measure of outlet density within 400 m of respondents' home postcode was grouped into tertiles. The analysis considered whether outlet density was associated with the number of cigarette brands adolescents could name, positive beliefs about smoking, whether smokers purchased cigarettes from shops themselves or through adult proxies and perceived cost of cigarettes. Models were stratified by adolescent smoking status. The path analyses indicated that outlet density was not associated with most outcomes, but small, significant direct effects on knowledge of cigarette brands among those who had never smoked were observed. With each increase in outlet density tertile the mean number of brands adolescents could name rose by 0.07 (mean = 1.60; SD = 1.18; range = 4). This suggests greater outlet densities may have affected adolescents' knowledge of cigarette brands but did not encourage positive attitudes to smoking, purchases from shops or lower cigarette

  16. Remaining Life Estimation Of Secondary Superheater Outlet On Industrial Electrical Boiler

    International Nuclear Information System (INIS)

    Soedardjo; Andryansyah; Arhatari, B.D.; Natsir, Muhammad; Triyadi, Ari; Farokhi

    2001-01-01

    Remaining life estimation of secondary superheater header outlet (SSHO) on industrial electrical boiler has been carried out. Estimation conducted by the observation of microstructure cavitation development based on Neubauer and Wedel theory. The result is available for isolated cavitation development present yet. That Secondary Superheater Outlet component is in good condition after 14 years operated and predicted could be operated for 36 years again

  17. Application of the grey system theory for forecasting the content of 238U in soil near a uranium mine exhaust outlet

    International Nuclear Information System (INIS)

    Ye Yongjun; Ding Dexin; Li Xiangyang; Zhou Xinghuo; Liu Dong

    2008-01-01

    In order to forecast the content of 238 U in soil near a uranium mine exhaust outlet, a general GM(1,1) forecasting model was established based on grey system theory, analyzing association degree and residual error distinction. According to the measuring datum of the content of 238 U in soil near a uranium mine exhaust outlet from 2001 to 2006, used the model to forecast the content of 238 U in soil, The results show that the forecasting value agrees with the measuring results and the forecasting precision is higher; at the same time the content of 238 U in soil in 2007 is also forecasted based on the model, the relative error was 4.8%; which shows the GM(1,1) forecasting model has higher practical value, and is a effective method for forecasting the content of 238 U in soil near a uranium mine exhaust outlet. (authors)

  18. 16 CFR Appendix E to Part 436 - Sample Item 20(4) Table-Status of Company-Owned Outlets

    Science.gov (United States)

    2010-01-01

    ... RULES DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. E Appendix E to Part... 5Outlets Reacquired From Franchisees Column 6Outlets Closed Column 7Outlets Sold to Franchisees Column...

  19. The association between the geography of fast food outlets and childhood obesity rates in Leeds, UK.

    Science.gov (United States)

    Fraser, Lorna K; Edwards, Kimberley L

    2010-11-01

    To analyse the association between childhood overweight and obesity and the density and proximity of fast food outlets in relation to the child's residential postcode. This was an observational study using individual level height/weight data and geographic information systems methodology. Leeds in West Yorkshire, UK. This area consists of 476 lower super-output areas. Children aged 3-14 years who lived within the Leeds metropolitan boundaries (n=33,594). The number of fast food outlets per area and the distance to the nearest fast food outlet from the child's home address. The weight status of the child: overweight, obese or neither. 27.1% of the children were overweight or obese with 12.6% classified as obese. There is a significant positive correlation (pfood outlets and higher deprivation. A higher density of fast food outlets was significantly associated (p=0.02) with the child being obese (or overweight/obese) in the generalised estimating equation model which also included sex, age and deprivation. No significant association between distance to the nearest fast food outlet and overweight or obese status was found. There is a positive relationship between the density of fast food outlets per area and the obesity status of children in Leeds. There is also a significant association between fast food outlet density and areas of higher deprivation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  20. Flow visualization study of two-phase flow in a single bend outlet feeder pipe of a CANDU reactor

    International Nuclear Information System (INIS)

    Savalaxs, S.-A.; Lister, D.H.; Steward, F.R.

    2005-01-01

    In CANDU reactors, the feeder piping that is used to direct the high-temperature water coolant between the fuel channels and the steam generators is made of carbon steel. Since 1996, several CANDU stations have reported excessive corrosion of their outlet feeders. The first metre is particularity vulnerable because the piping there consists of single or double bends, which have relatively thin walls produced by the bending process. Early studies related the attack to the hydrodynamics of the coolant and verified that it was a type of flow-accelerated corrosion. In order to understand the hydrodynamics of the coolant in the outlet feeders by flow visualization, a full-scale transparent test section simulating the geometry and orientation of an outlet feeder bend with its upstream components was fabricated. The feeder consisted of a 54 mm diameter acrylic pipe with a 73 degree bend. This was connected to the upstream component with an acrylic simulation of a Grayloc flanged fitting. A test loop supplied room temperature water to the test section at flow rates up to 0.019 m3/s. Air could be injected into the water to give a mean volume fraction of up to 0.56. In this preliminary investigation, the size and velocity of air bubbles at different flow conditions and their distribution within the pipe bend were studied. Particular attention was paid to the flow pattern at the inside of the bend, where a CFD (computational fluid dynamics) code - Fluent 6.1-had failed to predict a liquid film in an earlier study. A high-speed digital video camera was used to determine the relation between bubble size and velocity. Such a relation should help to explain the discrepancy in the CFD modelling and provide the basis for accurate predictions of phase distribution in complex geometries at high flow rates. (authors)

  1. From Medical to Recreational Marijuana Sales: Marijuana Outlets and Crime in an Era of Changing Marijuana Legislation.

    Science.gov (United States)

    Freisthler, Bridget; Gaidus, Andrew; Tam, Christina; Ponicki, William R; Gruenewald, Paul J

    2017-06-01

    A movement from medical to recreational marijuana use allows for a larger base of potential users who have easier access to marijuana, because they do not have to visit a physician before using marijuana. This study examines whether changes in the density of marijuana outlets were related to violent, property, and marijuana-specific crimes in Denver, CO during a time in which marijuana outlets began selling marijuana for recreational, and not just medical, use. We collected data on locations of crimes, marijuana outlets and covariates for 481 Census block groups over 34 months (N = 16,354 space-time units). A Bayesian Poisson space-time model assessed statistical relationships between independent measures and crime counts within "local" Census block groups. We examined spatial "lag" effects to assess whether crimes in Census block groups adjacent to locations of outlets were also affected. Independent of the effects of covariates, densities of marijuana outlets were unrelated to property and violent crimes in local areas. However, the density of marijuana outlets in spatially adjacent areas was positively related to property crime in spatially adjacent areas over time. Further, the density of marijuana outlets in local and spatially adjacent blocks groups was related to higher rates of marijuana-specific crime. This study suggests that the effects of the availability of marijuana outlets on crime do not necessarily occur within the specific areas within which these outlets are located, but may occur in adjacent areas. Thus studies assessing the effects of these outlets in local areas alone may risk underestimating their true effects.

  2. Application of the PROMETHEE technique to determine depression outlet location and flow direction in DEM

    Science.gov (United States)

    Chou, Tien-Yin; Lin, Wen-Tzu; Lin, Chao-Yuan; Chou, Wen-Chieh; Huang, Pi-Hui

    2004-02-01

    With the fast growing progress of computer technologies, spatial information on watersheds such as flow direction, watershed boundaries and the drainage network can be automatically calculated or extracted from a digital elevation model (DEM). The stubborn problem that depressions exist in DEMs has been frequently encountered while extracting the spatial information of terrain. Several filling-up methods have been proposed for solving depressions. However, their suitability for large-scale flat areas is inadequate. This study proposes a depression watershed method coupled with the Preference Ranking Organization METHod for Enrichment Evaluations (PROMETHEEs) theory to determine the optimal outlet and calculate the flow direction in depressions. Three processing procedures are used to derive the depressionless flow direction: (1) calculating the incipient flow direction; (2) establishing the depression watershed by tracing the upstream drainage area and determining the depression outlet using PROMETHEE theory; (3) calculating the depressionless flow direction. The developed method was used to delineate the Shihmen Reservoir watershed located in Northern Taiwan. The results show that the depression watershed method can effectively solve the shortcomings such as depression outlet differentiating and looped flow direction between depressions. The suitability of the proposed approach was verified.

  3. Performance analysis of double organic Rankine cycle for discontinuous low temperature waste heat recovery

    International Nuclear Information System (INIS)

    Wang Dongxiang; Ling Xiang; Peng Hao

    2012-01-01

    This research proposes a double organic Rankine cycle for discontinuous waste heat recovery. The optimal operation conditions of several working fluids have been calculated by a procedure employing MATLAB and REFPROP. The influence of outlet temperature of heat source on the net power output, thermal efficiency, power consumption, mass flow rate, expander outlet temperature, cycle irreversibility and exergy efficiency at a given pinch point temperature difference (PPTD) has been analyzed. Pinch point analysis has also been employed to obtain a thermodynamic understanding of the ORC performance. Of all the working fluids investigated, some performances between each working fluid are rather similar. For a fixed low temperature heat source, the optimal operation condition should be mainly determined by the heat carrier of the heat source, and working fluids have limited influence. Lower outlet temperature of heat source does not always mean more efficient energy use. Acetone exhibits the least exergy destruction, while R245fa possesses the maximal exergy efficiency at a fixed PPTD. Wet fluids exhibit lower thermal efficiency than the others with the increasing of PPTD at a fixed outlet temperature of heat source. Dry and isentropic fluids offer attractive performance. - Highlights: ► We propose a double organic Rankine cycle for discontinuous waste heat recovery. ► Performance of organic Rankine cycle (ORC) is analyzed by pinch point analysis. ► The heat carrier of the heat source determines ORC optimal operation condition. ► Design of ORC heat exchangers prefers lower pinch point temperature difference.

  4. Investigation of ambient temperature on the performance of GE-F5 gas turbine

    International Nuclear Information System (INIS)

    Ghazikhani, M.; Taffazoli, D.; Manshori, N.

    2002-01-01

    The role of ambient temperature in determining the performance of GE-F5 gas turbine is analysed by investigating the Shirvan gas turbine power plant 10 MW , 15 MW and 20 MW power output. These parameters have been brought as a function of ambient temperature. The results show when ambient temperature increases 1 deg C, The compressor pressure decreases about 20 k Pa, compressor outlet temperature increases about 1.13 deg C and exhaust temperature increases about 2.5 deg C. It is revealed that variations are due to decreasing the efficiency of compressor and less due to mass flow rate of air reduction as ambient temperature increases at constant power output. The results shows cycle efficiency reduces 3% with increasing 50 of ambient temperature, also the m increases as ambient temperature increase for constant turbine work. These are also because of reducing the compressor efficiency as ambient temperature increases

  5. Mean energy of ions at outlet of a type Ecr plasma source

    International Nuclear Information System (INIS)

    Gutierrez T, C.; Gonzalez D, J.

    1998-01-01

    In this work it is described the calculations to mean energy of the ions in the extraction zone of a type Ecr plasma source considering the presence of a metallic substrate. This zone is characterized by the existence of a divergent magnetic field. It is showed that mean energy is function as the distance between the outlet and substrate as the value of the external magnetic field. (Author)

  6. Velocities of antarctic outlet glaciers determined from sequential Landsat images

    Science.gov (United States)

    MacDonald, Thomas R.; Ferrigno, Jane G.; Williams, Richard S.; Lucchitta, Baerbel K.

    1989-01-01

    Approximately 91.0 percent of the volume of present-day glacier ice on Earth is in Antarctica; Greenland contains about another 8.3 percent of the volume. Thus, together, these two great ice sheets account for an estimated 99.3 percent of the total. Long-term changes in the volume of glacier ice on our planet are the result of global climate change. Because of the relationship of global ice volume to sea level (± 330 cubic kilometers of glacier ice equals ± 1 millimeter sea level), changes in the mass balance of the antarctic ice sheet are of particular importance.Whether the mass balance of the east and west antarctic ice sheets is positive or negative is not known. Estimates of mass input by total annual precipitation for the continent have been made from scattered meteorological observations (Swithinbank 1985). The magnitude of annual ablation of the ice sheet from calving of outlet glaciers and ice shelves is also not well known. Although the velocities of outlet glaciers can be determined from field measurements during the austral summer,the technique is costly, does not cover a complete annual cycle,and has been applied to just a few glaciers. To increase the number of outlet glaciers in Antarctica for which velocities have been determined and to provide additional data for under-standing the dynamics of the antarctic ice sheets and their response to global climate change, sequential Landsat image of several outlet glaciers were measured.

  7. KORELASI PENGGUNAAN BAHASA INGGRIS DALAM PENAMAAN FACTORY OUTLET (FO DI BANDUNG TERHADAP KEPUTUSAN PEMBELIAN

    Directory of Open Access Journals (Sweden)

    Gartika Rahmasari

    2016-03-01

        Abstrak - Bahasa Inggris merupakan bahasa yang memiliki prestise atau kedudukan yang tinggi, bahkan di Indonesia yang memiliki bahasa Indonesia sebagai bahasa nasional. Bahasa Inggris sebagai bahasa internasional mendapatkan apresiasi lebih tinggi dibandingkan dengan bahasa Indonesia, khususnya di bidang pariwisata. Bandung sebagai salah satu tujuan pariwisata, khususnya wisata kuliner dan tujuan belanja, tidak terkecuali mendapat pengaruh yang besar dalam hal penggunaan bahasa Inggris. Hal ini dapat dilihat dari penggunaan sejumlah nama Factory Outlet yang ada di Bandung, yang hampir sebagian besar menggunakan bahasa Ingris atau serapan bahasa Inggris sebagai “brand” atau nama yang digunakan oleh Factory Outlet yang tersebar di seluruh Bandung. Jurnal ini merupakan study literatur yang meneliti tentang hubungan penggunaan bahasa Asing dalam nama Factory Outlet  (FO terhadap keputusan pembelian. Yang menjadi responden yang diteliti dalam penelitian ini adalah mahasiswa Ilmu Komunikasi, Universitas Telkom sebanyak 55 responden, dengan rentang usia 17-20 tahun. Dari hasil penelitian, diketahui bahwa secara umum, penggunaan bahasa Inggris dalam penamaan Factory Outlet (FO mempengaruhi keputusan responden untuk berbelanja ke FO tersebut.   Kata Kunci: Keputusan Pembelian, Factory Outlet, FO, Bahasa Inggris.

  8. Proximity of off-premise alcohol outlets and heavy alcohol consumption: a cohort study.

    Science.gov (United States)

    Halonen, Jaana I; Kivimäki, Mika; Virtanen, Marianna; Pentti, Jaana; Subramanian, S V; Kawachi, Ichiro; Vahtera, Jussi

    2013-09-01

    Availability of alcohol has been associated with alcohol consumption in cross-sectional studies. We examined longitudinally whether change in proximity to off-premise (i.e., no consumption on the premises) beer and liquor outlets is associated with heavy alcohol consumption. Distances from 54,778 Finnish Public Sector study participants' homes to the nearest off-premise beer and liquor outlets were calculated using Global Positioning System-coordinates. Between-individual analyses were used to study the effects of distance to the nearest outlet on heavy alcohol use, and within-individual analyses to study the effects of a change in distance on change in heavy use. Mean follow-up time in 2000-2009 was 6.8 (standard deviation 2.0) years. In a between-individual analysis, decrease from ≥500 m to alcohol use in women (odds ratio 1.23, 95% CI 1.05-1.44), but not in men. In a within-individual analysis decrease from 500 m to 0m in log-transformed continuous distance to the nearest beer outlet increased the odds of heavy alcohol consumption in women by 13% (odds ratio 1.13, 95% CI 1.01-1.27). For the corresponding change in distance to liquor outlet the increase was 3% (odds ratio 1.03, 95% CI 0.97-1.09). Change in distance from home to the nearest off-premise alcohol outlet affects the risk of heavy alcohol consumption in women. This evidence supports policies that restrict physical availability of alcohol. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Neighborhood alcohol outlet density and genetic influences on alcohol use: evidence for gene-environment interaction.

    Science.gov (United States)

    Slutske, Wendy S; Deutsch, Arielle R; Piasecki, Thomas M

    2018-05-07

    Genetic influences on alcohol involvement are likely to vary as a function of the 'alcohol environment,' given that exposure to alcohol is a necessary precondition for genetic risk to be expressed. However, few gene-environment interaction studies of alcohol involvement have focused on characteristics of the community-level alcohol environment. The goal of this study was to examine whether living in a community with more alcohol outlets would facilitate the expression of the genetic propensity to drink in a genetically-informed national survey of United States young adults. The participants were 2434 18-26-year-old twin, full-, and half-sibling pairs from Wave III of the National Longitudinal Study of Adolescent to Adult Health. Participants completed in-home interviews in which alcohol use was assessed. Alcohol outlet densities were extracted from state-level liquor license databases aggregated at the census tract level to derive the density of outlets. There was evidence that the estimates of genetic and environmental influences on alcohol use varied as a function of the density of alcohol outlets in the community. For example, the heritability of the frequency of alcohol use for those residing in a neighborhood with ten or more outlets was 74% (95% confidence limits = 55-94%), compared with 16% (95% confidence limits = 0-34%) for those in a neighborhood with zero outlets. This moderating effect of alcohol outlet density was not explained by the state of residence, population density, or neighborhood sociodemographic characteristics. The results suggest that living in a neighborhood with many alcohol outlets may be especially high-risk for those individuals who are genetically predisposed to frequently drink.

  10. Sensitivity Studies of Advanced Reactors Coupled to High Temperature Electrolysis (HTE) Hydrogen Production Processes

    International Nuclear Information System (INIS)

    Edwin A. Harvego; Michael G. McKellar; James E. O'Brien; J. Stephen Herring

    2007-01-01

    High Temperature Electrolysis (HTE), when coupled to an advanced nuclear reactor capable of operating at reactor outlet temperatures of 800 C to 950 C, has the potential to efficiently produce the large quantities of hydrogen needed to meet future energy and transportation needs. To evaluate the potential benefits of nuclear-driven hydrogen production, the UniSim process analysis software was used to evaluate different reactor concepts coupled to a reference HTE process design concept. The reference HTE concept included an Intermediate Heat Exchanger and intermediate helium loop to separate the reactor primary system from the HTE process loops and additional heat exchangers to transfer reactor heat from the intermediate loop to the HTE process loops. The two process loops consisted of the water/steam loop feeding the cathode side of a HTE electrolysis stack, and the steam or air sweep loop used to remove oxygen from the anode side. The UniSim model of the process loops included pumps to circulate the working fluids and heat exchangers to recover heat from the oxygen and hydrogen product streams to improve the overall hydrogen production efficiencies. The reference HTE process loop model was coupled to separate UniSim models developed for three different advanced reactor concepts (a high-temperature helium cooled reactor concept and two different supercritical CO2 reactor concepts). Sensitivity studies were then performed to evaluate the affect of reactor outlet temperature on the power cycle efficiency and overall hydrogen production efficiency for each of the reactor power cycles. The results of these sensitivity studies showed that overall power cycle and hydrogen production efficiencies increased with reactor outlet temperature, but the power cycle producing the highest efficiencies varied depending on the temperature range considered

  11. Factors Influencing Demand for a Producer-Owned Beef Retail Outlet

    OpenAIRE

    Lusk, Jayson L.; Cevallos, Edgar

    2004-01-01

    As the farm-to-retail price spread continues to grow, come cattle producers a beginning to consider integrating into the retail sector. Such a venture would require large investments in capital with uncertain return. This study seeks to determine the potential success of a stand-alone retail outlet selling “all natural†beef in an affluent area of Jackson, MS. Using choice-based conjoint analysis, demand for the new retail outlet is modeled as a function of the beef price at the store, dis...

  12. Geocoding routinely collected administrative data to measure access to alcohol outlets in Wales

    Directory of Open Access Journals (Sweden)

    Richard Fry

    2017-04-01

    All authorities were able to provide an actual or approximate license issue date, allowing us to summarise the number of outlets annually. Several authorities were unable to provide precise outlet closure dates, so the date of the last interaction with the outlet was used to generate an approximate end date. One-half of the unitary authorities were able to provide the On/Off sales status of outlets, and 9 were able to provide opening hours. From these data we were able to geocode 53% (range 28% to 72% by local authority using GIS, the remaining 47% were matched using Google products to verify and extract a precise geographic location. Conclusions The collation and processing of retrospective alcohol outlet data was successfully completed to enable the building of a longitudinal exposure dataset. There was considerable variation between the unitary authorities in the quality of address data, and data related to the availability of alcohol, for example opening hours. The lack of address structure required us to devise a manual address matching process to capture the addresses that could not be geocoded. To aid future data linkage based evaluations to provide policy evidence in a timely manner, local government datasets should use standardised data fields, including addresses and Point-of-Capture address verification.

  13. Analysis of transient thermal response in the outlet plenum of an LMFBR

    International Nuclear Information System (INIS)

    Yang, J.W.

    1976-05-01

    A two-zone mixing model based on the lumped-parameter approach was developed for the analysis of transient thermal response in the upper outlet plenum of an LMFBR. The one-dimensional turbulent jet flow equations were solved to determine the maximum penetration of the core flow. The maximum penetration is used as the criterion for dividing the sodium region into two mixing zones. The lumped-parameter model considers the transient sodium temperature affected by the thermal expansion of sodium, heat transfer with cover gas, heat capacity of different sections of metal and the addition of bypass flow into the plenum. Numerical calculations were performed for two cases. The first case corresponds to a normal scram followed by flow coast-down. The second case represents the double-ended pipe rupture at the inlet of cold leg followed by reactor scram. The results indicate that effects of flow stratification, chimney height, metal heat capacity and bypass flow are important for transient sodium temperature calculation. Thermal expansion of sodium and heat transfer with the cover gas does not play any significant role on sodium temperature. This two-zone mixing model will be a part of the thermohydraulic transient code SSC

  14. 7 CFR 993.108 - Non-human consumption outlet.

    Science.gov (United States)

    2010-01-01

    ... consumption outlet means any livestock feeder or manufacturer of inedible syrup, industrial alcohol, animal... FR 8278, Sept. 2, 1961; 26 FR 8483, Sept. 9, 1961] Effective Date Note: At 70 FR 30613, May 27, 2005...

  15. Rapid Holocene thinning of outlet glaciers followed by readvance in the western Ross Embayment, Antarctica

    Science.gov (United States)

    Jones, R. S.; Whitmore, R.; Mackintosh, A.; Norton, K. P.; Eaves, S.; Stutz, J.

    2017-12-01

    Investigating Antarctic deglaciation following the LGM provides an opportunity to better understand patterns, mechanisms and drivers of ice sheet retreat. In the Ross Sea sector, geomorphic features preserved on the seafloor indicate that streaming East Antarctic outlet glaciers once extended >100 km offshore of South Victoria Land prior to back-stepping towards their modern configurations. In order to adequately interpret the style and causes of this retreat, the timing and magnitude of corresponding ice thickness change is required. We present new constraints on ice surface lowering from Mawson Glacier, an outlet of the East Antarctic Ice Sheet that flows into the western Ross Sea. Surface-exposure (10Be) ages from samples collected in elevation transects above the modern ice surface reveal that rapid thinning occurred at 5-8 ka, broadly coeval with new ages of grounding-line retreat at 6 ka and rapid thinning recorded at nearby Mackay Glacier at 7 ka. Our data also show that a moraine formed near to the modern ice margin of Mawson Glacier at 0.8 ka, which, together with historical observations, indicates that glaciers in this region readvanced during the last thousand years. We argue that 1) the accelerated thinning of outlet glaciers was driven by local grounding-line retreat through overdeepened basins during the early-mid Holocene, and 2) the glaciers subsequently readvanced, possibly linked to late Holocene sea-ice expansion, before retreating to their current positions. Our work demonstrates that these outlet glaciers were closely coupled to environmental and topography-induced perturbations near their termini throughout the Holocene.

  16. 16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...

  17. Gastric diverticulum causing gastric outlet obstruction in the setting of duodenal atresia

    Directory of Open Access Journals (Sweden)

    Devashis Mukherjee

    2018-04-01

    Full Text Available Duodenal obstruction due to duodenal atresia occurs in 1 in 10,000 live births and is the most common type of intestinal obstruction in neonates [1–3]. Gastric outlet obstruction in the newborn period from causes other than hypertrophic pyloric stenosis is very uncommon [3]. Potential etiologies include gastric volvulus, antral web, and duplication cysts. Gastric diverticula in the infant is even more rare, with only a few case reports published, and only one describes a gastric diverticulum in the presence of a duodenal atresia [4–8]. In this report, we describe the first case of a gastric outlet obstruction due to a gastric diverticulum in the presence of duodenal atresia. Keywords: Duodenal atresia, Gastric diverticulum, Gastric outlet obstruction

  18. Examining the interaction between food outlets and outdoor food advertisements with primary school food environments.

    Science.gov (United States)

    Walton, Mat; Pearce, Jamie; Day, Peter

    2009-09-01

    Schools are commonly seen as a site of intervention to improve children's nutrition, and prevent excess weight gain. Schools may have limited influence over children's diets; however, with home and community environments also exerting an influence within schools. This study considered the environment of food outlets and outdoor food advertisements surrounding four case study primary schools in New Zealand, and the impact of that external environment on within-school food environments. The shortest travel route between school and home addresses, and the number of food outlets and advertisements passed on that route, was calculated for each student. Interviews with school management were conducted. The schools with a higher percentage of students passing food outlets and advertisements considered that their presence impacted on efforts within schools to improve the food environment. Limiting students' exposure to food outlets and outdoor food adverts through travel route planning, reducing advertising, or limiting the location of food outlets surrounding schools could be explored as intervention options to support schools in promoting nutrition.

  19. DEM study of granular discharge rate through a vertical pipe with a bend outlet in small absorber sphere system

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tianjin, E-mail: tjli@tsinghua.edu.cn; Zhang, He; Liu, Malin; Huang, Zhiyong; Bo, Hanliang; Dong, Yujie

    2017-04-01

    Highlights: • The work concerns granular flow in a vertical pipe with a bend. • Discharge rate fluctuation in vertical pipe are mainly from velocity fluctuation. • Steady discharge rate decreases rapidly and saturates with μ{sub s} increasing. • Steady discharge rate W{sub s} still obey the 5/2 power law of pipe internal diameter. • A correlation developed for steady discharge rate for this new geometry. - Abstract: Absorber sphere pneumatic conveying is a special application of pneumatic conveying technique in the pebble bed High Temperature Gas-Cooled Reactor (HTGR or HTR). Granular discharge through a vertical pipe with a bend outlet is one of the control modes to determine solid mass flowrate which is an important parameter for the design of absorber sphere pneumatic conveying. Granular discharge rate through the vertical pipe with a bend outlet in the small absorber sphere system are investigated by discrete element method simulation. The effect of geometry parameters on discharge rate, the discharge rate fluctuation in the vertical pipe, and the effect of friction on steady discharge rate (W{sub s}) are analyzed and discussed. The phenomena of discharge rate fluctuation in the vertical pipe are observed, which are mainly resulted from the evolution of the average downward granular velocity. The steady discharge rate decreases rapidly with sliding friction coefficient increasing from 0.125 to 0.5, and gradually saturates with the friction coefficient further increasing from 0.5 to 1. It is interesting that the linear relation between W{sub s}{sup 2/5} and pipe internal diameter D with zero intercept are found for the vertical pipe discharge with a bend outlet, which is different from the orifice discharge through a hopper or silo with none-zero intercept. A correlation similar to Beverloo’s correlation is developed to predict the steady discharge rate through the vertical pipe with a bend outlet. These results are helpful for the design of sphere

  20. Abandonment of the low level outlet structure at the McGregor South Dam

    Energy Technology Data Exchange (ETDEWEB)

    Mack, D.L; Murray, T.K. [Klohn-Crippen Consultants Ltd., Calgary, AB (Canada); Soutar, B.M. [Alberta Transportation, Edmonton, AB (Canada)

    2008-07-01

    The Carseland-Bow River Headworks (CBRH) is a major multi-purpose water delivery system, situated in southern Alberta. It supplies water to 87,000 hectares of agricultural land and several municipalities. The system was originally built starting in 1909. It consists of diversion works on the Bow River, 65 kilometres of canal, and the McGregor and Little Bow reservoirs. In the 1950s, the system was rehabilitated by the Prairie Farm Rehabilitation Administration (PFRA), and Travers Reservoir was added in 1954. In 1973, ownership and operation of the CBRH system was turned over to Alberta Environment. In 2001, Alberta Transportation implemented a major program to rehabilitate and upgrade the CBRH system. This program included increasing the capacity of the canals and structures, and upgrading the dams to meet current dam safety guidelines. The project involved raising the north and south dams, providing an auxiliary spillway to accommodate the probable maximum flood (PMF), and rehabilitating the existing reservoir inlet and low level outlet structures. This paper discussed the abandonment of the existing low level outlet structure located within the south dam. The paper discussed the existing dams and outlet structure as well as the south dam and outlet structure. The abandonment of the existing low level outlet structure was discussed in terms of general construction; demolition; upstream conduits and gatewell; and downstream conduit. Several illustrations and photographs of the dam and the demolition were presented. It was concluded that the in-place abandonment of the existing low level outlet structure at the McGregor South Dam provides significant advantages, including eliminating the need to construct and remove an extensive cofferdam within the reservoir. 6 refs., 2 tabs., 4 figs.

  1. Temporal and spatial dispersion of human body temperature during deep hypothermia.

    Science.gov (United States)

    Opatz, O; Trippel, T; Lochner, A; Werner, A; Stahn, A; Steinach, M; Lenk, J; Kuppe, H; Gunga, H C

    2013-11-01

    Clinical temperature management remains challenging. Choosing the right sensor location to determine the core body temperature is a particular matter of academic and clinical debate. This study aimed to investigate the relationship of measured temperatures at different sites during surgery in deep hypothermic patients. In this prospective single-centre study, we studied 24 patients undergoing cardiothoracic surgery: 12 in normothermia, 3 in mild, and 9 in deep hypothermia. Temperature recordings of a non-invasive heat flux sensor at the forehead were compared with the arterial outlet temperature of a heart-lung machine, with the temperature on a conventional vesical bladder thermistor and, for patients undergoing deep hypothermia, with oesophageal temperature. Using a linear model for sensor comparison, the arterial outlet sensor showed a difference among the other sensor positions between -0.54 and -1.12°C. The 95% confidence interval ranged between 7.06 and 8.82°C for the upper limit and -8.14 and -10.62°C for the lower limit. Because of the hysteretic shape, the curves were divided into phases and fitted into a non-linear model according to time and placement of the sensors. During cooling and warming phases, a quadratic relationship could be observed among arterial, oesophageal, vesical, and cranial temperature recordings, with coefficients of determination ranging between 0.95 and 0.98 (standard errors of the estimate 0.69-1.12°C). We suggest that measured surrogate temperatures as indices of the cerebral temperature (e.g. vesical bladder temperature) should be interpreted with respect to the temporal and spatial dispersion during cooling and rewarming phases.

  2. Improved Algorithms for Blending Dam Releases to Meet Downstream Water-Temperature Targets in the CE-QUAL-W2 Water-Quality Model

    Science.gov (United States)

    Rounds, S. A.; Buccola, N. L.

    2014-12-01

    The two-dimensional (longitudinal, vertical) water-quality model CE-QUAL-W2, version 3.7, was enhanced with new features to help dam operators and managers efficiently explore and optimize potential solutions for temperature management downstream of thermally stratified reservoirs. Such temperature management often is accomplished by blending releases from multiple dam outlets that access water of different temperatures at different depths in the reservoir. The original blending algorithm in this version of the model was limited to mixing releases from two outlets at a time, and few constraints could be imposed. The new enhanced blending algorithm allows the user to (1) specify a time-series of target release temperatures, (2) designate from 2 to 10 floating or fixed-elevation outlets for blending, (3) impose maximum head constraints as well as minimum and maximum flow constraints for any blended outlet, and (4) set a priority designation for each outlet that allows the model to choose which outlets to use and how to balance releases among them. The modified model was tested against a previously calibrated model of Detroit Lake on the North Santiam River in northwestern Oregon, and the results compared well. The enhanced model code is being used to evaluate operational and structural scenarios at multiple dam/reservoir systems in the Willamette River basin in Oregon, where downstream temperature management for endangered fish is a high priority for resource managers and dam operators. These updates to the CE-QUAL-W2 blending algorithm allow scenarios involving complicated dam operations and/or hypothetical outlet structures to be evaluated more efficiently with the model, with decreased need for multiple/iterative model runs or preprocessing of model inputs to fully characterize the operational constraints.

  3. Neighborhood Characteristics, Alcohol Outlet Density, and Alcohol-Related Calls-for-Service: A Spatiotemporal Analysis in a Wet Drinking Country

    Directory of Open Access Journals (Sweden)

    Miriam Marco

    2017-11-01

    Full Text Available Alcohol outlets have been associated with different social problems, such as crime, violence, intimate partner violence, and child maltreatment. The spatial analysis of neighborhood availability of alcohol outlets is key for better understanding of these influences. Most studies on the spatial distribution of alcohol outlets in the community have been conducted in U.S. cities, but few studies have assessed this spatial distribution in other countries where the drinking culture may differ. The aim of this study was to analyze the spatiotemporal distribution of alcohol outlets in the city of Valencia, Spain, and its relationship with neighborhood-level characteristics, as well as to examine the influence of alcohol outlet density on alcohol-related police calls-for-service. Spain is characterized by having a “wet” drinking culture and greater social acceptance of drinking compared to the U.S. Data on alcohol outlets between 2010–2015 in three categories (off-premise, restaurants and cafes, and bars were used for the analysis. We used the 552 census block groups allocated within the city as neighborhood unit. Data were analyzed using Bayesian spatiotemporal regression models. Results showed different associations between alcohol outlets categories and neighborhood variables: off-premise density was higher in areas with lower economic status, higher immigrant concentration, and lower residential instability; restaurant and cafe density was higher in areas with higher spatially-lagged economic status, and bar density was higher in areas with higher economic status and higher spatially-lagged economic status. Furthermore, restaurant and cafe density was negatively associated with alcohol-related police calls-for-service, while bar density was positively associated with alcohol-related calls-for-service. These results can be used to inform preventive strategies for alcohol-related problems at the neighborhood-level in Spain or other countries

  4. Expiry of medicines in supply outlets in Uganda.

    Science.gov (United States)

    Nakyanzi, Josephine Katabaazi; Kitutu, Freddy Eric; Oria, Hussein; Kamba, Pakoyo Fadhiru

    2010-02-01

    The expiry of medicines in the supply chain is a serious threat to the already constrained access to medicines in developing countries. We investigated the extent of, and the main contributing factors to, expiry of medicines in medicine supply outlets in Kampala and Entebbe, Uganda. A cross-sectional survey of six public and 32 private medicine outlets was done using semi-structured questionnaires. The study area has 19 public medicine outlets (three non-profit wholesalers, 16 hospital stores/pharmacies), 123 private wholesale pharmacies and 173 retail pharmacies, equivalent to about 70% of the country's pharmaceutical businesses. Our findings indicate that medicines prone to expiry include those used for vertical programmes, donated medicines and those with a slow turnover. Awareness about the threat of expiry of medicines to the delivery of health services has increased. We have adapted training modules to emphasize management of medicine expiry for pharmacy students, pharmacists and other persons handling medicines. Our work has also generated more research interest on medicine expiry in Uganda. Even essential medicines expire in the supply chain in Uganda. Sound coordination is needed between public medicine wholesalers and their clients to harmonize procurement and consumption as well as with vertical programmes to prevent duplicate procurement. Additionally, national medicine regulatory authorities should enforce existing international guidelines to prevent dumping of donated medicine. Medicine selection and quantification should be matched with consumer tastes and prescribing habits. Lean supply and stock rotation should be considered.

  5. The Society of Thoracic Surgeons, The Society of Cardiovascular Anesthesiologists, and The American Society of ExtraCorporeal Technology: Clinical Practice Guidelines for Cardiopulmonary Bypass--Temperature Management During Cardiopulmonary Bypass.

    Science.gov (United States)

    Engelman, Richard; Baker, Robert A; Likosky, Donald S; Grigore, Alina; Dickinson, Timothy A; Shore-Lesserson, Linda; Hammon, John W

    2015-08-01

    In order to improve our understanding of the evidence-based literature supporting temperature management during adult cardiopulmonary bypass, The Society of Thoracic Surgeons, the Society of Cardiovascular Anesthesiology and the American Society of ExtraCorporeal Technology tasked the authors to conduct a review of the peer-reviewed literature, including: 1) optimal site for temperature monitoring, 2) avoidance of hyperthermia, 3) peak cooling temperature gradient and cooling rate, and 4) peak warming temperature gradient and rewarming rate. Authors adopted the American College of Cardiology/American Heart Association method for development clinical practice guidelines, and arrived at the following recommendations: CLASS I RECOMMENDATIONS: a)The oxygenator arterial outlet blood temperature is recommended to be utilized as a surrogate for cerebral temperature measurement during CPB. (Class I, Level C) b)To monitor cerebral perfusate temperature during warming, it should be assumed that the oxygenator arterial outlet blood temperature under-estimates cerebral perfusate temperature. (Class I, Level C) c)Surgical teams should limit arterial outlet blood temperature to<37°C to avoid cerebral hyperthermia. (Class 1, Level C) d)Temperature gradients between the arterial outlet and venous inflow on the oxygenator during CPB cooling should not exceed 10°C to avoid generation of gaseous emboli. (Class 1, Level C) e)Temperature gradients between the arterial outlet and venous inflow on the oxygenator during CPB rewarming should not exceed 10°C to avoid out-gassing when blood is returned to the patient. (Class 1, Level C) CLASS IIa a)Pulmonary artery or nasopharyngeal temperature recording is reasonable for weaning and immediate post-bypass temperature measurement. (Class IIa, Level C)b)Rewarming when arterial blood outlet temperature ≥30° C: i.To achieve the desired temperature for separation from bypass, it is reasonable to maintain a temperature gradient between

  6. Combined diurnal variations of discharge and hydrochemistry of the Isunnguata Sermia outlet, Greenland Ice Sheet

    Science.gov (United States)

    Graly, Joseph; Harrington, Joel; Humphrey, Neil

    2017-05-01

    In order to examine daily cycles in meltwater routing and storage in the Isunnguata Sermia outlet of the Greenland Ice Sheet, variations in outlet stream discharge and in major element hydrochemistry were assessed over a 6-day period in July 2013. Over 4 days, discharge was assessed from hourly photography of the outlet from multiple vantages, including where midstream naled ice provided a natural gauge. pH, electrical conductivity, suspended sediment, and major element and anion chemistry were measured in samples of stream water collected every 3 h.Photography and stream observations reveal that although river width and stage have only slight diurnal variation, there are large diurnal changes in discharge shown by the doubling in width of what we term the active channel, which is characterized by large standing waves and fast flow. The concentration of dissolved solutes follows a sinusoidal diurnal cycle, except for large and variable increases in dissolved solutes during the stream's waning flow. Solute concentrations vary by ˜ 30 % between diurnal minima and maxima. Discharge maxima and minima lag temperature and surface melt by 3-7 h; diurnal solute concentration minima and maxima lag discharge by 3-6 h.This phase shift between discharge and solute concentration suggests that during high flow, water is either encountering more rock material or is stored in longer contact with rock material. We suggest that expansion of a distributed subglacial hydrologic network into seldom accessed regions during high flow could account for these phenomena, and for a spike of partial silicate reaction products during waning flow, which itself suggests a pressure threshold-triggered release of stored water.

  7. Temperature etalon of WWER-440 reactor

    International Nuclear Information System (INIS)

    Stanc, S.; Slanina, M.

    2001-01-01

    The presentation deals with the description, parameters and advantages of use of the temperature etalon. The system ensures temperature measurement of reactor outlet and inlet temperatures with high accuracy. Accuracy of temperature measurement is 0.18 deg C, accuracy of temperature difference measurement is 0.14 deg C, both with probability 0.95. Using the temperature etalon it is possible to increase accuracy of the standard temperature reactor measurements and to check their accuracy in the course of power reactor statuses in every measurement cycle. Temperature reactor etalon was installed in 12 WWER-440 units in Slovakia, Bohemia and Bulgaria. (Authors)

  8. Simulating potential structural and operational changes for Detroit Dam on the North Santiam River, Oregon, for downstream temperature management

    Science.gov (United States)

    Buccola, Norman L.; Rounds, Stewart A.; Sullivan, Annett B.; Risley, John C.

    2012-01-01

    Detroit Dam was constructed in 1953 on the North Santiam River in western Oregon and resulted in the formation of Detroit Lake. With a full-pool storage volume of 455,100 acre-feet and a dam height of 463 feet, Detroit Lake is one of the largest and most important reservoirs in the Willamette River basin in terms of power generation, recreation, and water storage and releases. The U.S. Army Corps of Engineers operates Detroit Dam as part of a system of 13 reservoirs in the Willamette Project to meet multiple goals, which include flood-damage protection, power generation, downstream navigation, recreation, and irrigation. A distinct cycle in water temperature occurs in Detroit Lake as spring and summer heating through solar radiation creates a warm layer of water near the surface and isolates cold water below. Controlling the temperature of releases from Detroit Dam, therefore, is highly dependent on the location, characteristics, and usage of the dam's outlet structures. Prior to operational changes in 2007, Detroit Dam had a well-documented effect on downstream water temperature that was problematic for endangered salmonid fish species, releasing water that was too cold in midsummer and too warm in autumn. This unnatural seasonal temperature pattern caused problems in the timing of fish migration, spawning, and emergence. In this study, an existing calibrated 2-dimensional hydrodynamic water-quality model [CE-QUAL-W2] of Detroit Lake was used to determine how changes in dam operation or changes to the structural release points of Detroit Dam might affect downstream water temperatures under a range of historical hydrologic and meteorological conditions. The results from a subset of the Detroit Lake model scenarios then were used as forcing conditions for downstream CE-QUAL-W2 models of Big Cliff Reservoir (the small reregulating reservoir just downstream of Detroit Dam) and the North Santiam and Santiam Rivers. Many combinations of environmental, operational, and

  9. Research program of the high temperature engineering test reactor for upgrading the HTGR technology

    International Nuclear Information System (INIS)

    Kunitomi, Kazuhiko; Tachibana, Yukio; Takeda, Takeshi; Saikusa, Akio; Sawa, Kazuhiro

    1997-07-01

    The High Temperature Engineering Test Reactor (HTTR) is a graphite-moderated and helium-cooled reactor with an outlet power of 30 MW and outlet coolant temperature of 950degC, and its first criticality will be attained at the end of 1997. In the HTTR, researches establishing and upgrading the technology basis necessary for an HTGR and innovative basic researches for a high temperature engineering will be conducted. A research program of the HTTR for upgrading the technology basis for the HTGR was determined considering realization of future generation commercial HTGRs. This paper describes a research program of the HTTR. (author)

  10. The roles of outlet density and norms in alcohol use disorder

    OpenAIRE

    Ahern, J; Balzer, L; Galea, S

    2015-01-01

    © 2015 Elsevier Ireland Ltd. Background: Alcohol outlet density and norms shape alcohol consumption. However, due to analytic challenges we do not know: (a) if alcohol outlet density and norms also shape alcohol use disorder, and (b) whether they act in combination to shape disorder. Methods: We applied a new targeted minimum loss-based estimator for rare outcomes (rTMLE) to a general population sample from New York City (N= 4000) to examine the separate and combined relations of neighborhood...

  11. Ayurvedic medicine in Mauritius: Profile of Ayurvedic outlet, use, sale, distribution, regulation and importation.

    Science.gov (United States)

    Elaheebocus, Naailah; Mahomoodally, M Fawzi

    2017-02-02

    Ayurvedic medicine (AM) is a legalised alternative traditional medical system in the multicultural tropical island of Mauritius. A panoply of Ayurvedic specialised shops/centres involved in the provision of Ayurvedic services hereafter termed as 'outlets' operates in different regions of the island and is extensively exploited by a significant number of Mauritians. Nonetheless, there is currently no study geared towards studying the status of AM and profile of Ayurvedic outlets in Mauritius and there is undoubtedly a dearth of standardized regulatory framework governing the practice of AM in Mauritius. The present study attempts to study the profile of Ayurvedic outlets, sale, distribution, regulation and importation of AM in Mauritius. To evaluate the characteristics profile of Ayurvedic shops/clinics/pharmacies/centres, to document common Ayurvedic products used in the treatment and management of diseases, and to analyse existing regulatory control of AM in Mauritius. Ayurvedic outlets were identified using a random approach. Once permission granted, outlets were visited where face-to-face interviews with Ayurvedic practitioners/directors/dispensers were undertaken using a semi-structured questionnaire. The characteristics of the outlets with respect to the type of business registration, procurement and dispensing of products, registration and qualification of personnels employed amongst others were studied. The International Classification of Diseases (ICD) 10 was used to classify common AM dispensed to patients. Additionally, information was sought from local authorities pertaining to existing legislation governing the importation and regulation of AM in Mauritius. A total of 16 Ayurvedic outlets ('pharmacies' (n=3), clinics (n=2), shops (n=5) and centres (n=6)) was surveyed. Six outlets dispensed AM strictly on prescription only after consultation with an onsite full-time employed registered Ayurvedic practitioner. Seven outlets offered AM both on prescription

  12. A study on different thermodynamic cycle schemes coupled with a high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Qu, Xinhe; Yang, Xiaoyong; Wang, Jie

    2017-01-01

    Highlights: • The features of three different power generation schemes, including closed Brayton cycle, non-reheating combined cycle and reheating combined cycle, coupled with high temperature gas-cooled reactor (HTGR) were investigated and compared. • The effects and mechanism of reactor core outlet temperature, compression ratio and other key parameters over cycle characteristics were analyzed by the thermodynamic models.. • It is found that reheated combined cycle has the highest efficiency. Reactor outlet temperature and main steam parameters are key factors to improve the cycle’s performance. - Abstract: With gradual increase in reactor outlet temperature, the efficient power conversion technology has become one of developing trends of (very) high temperature gas-cooled reactors (HTGRs). In this paper, different cycle power generation schemes for HTGRs were systematically studied. Physical and mathematical models were established for these three cycle schemes: closed Brayton cycle, simple combined cycle, and reheated combined cycle. The effects and mechanism of key parameters such as reactor core outlet temperature, reactor core inlet temperature and compression ratio on the features of these cycles were analyzed. Then, optimization results were given with engineering restrictive conditions, including pinch point temperature differences. Results revealed that within the temperature range of HTGRs (700–900 °C), the reheated combined cycle had the highest efficiency, while the simple combined cycle had the lowest efficiency (900 °C). The efficiencies of the closed Brayton cycle, simple combined cycle and reheated combined cycle are 49.5%, 46.6% and 50.1%, respectively. These results provide insights on the different schemes of these cycles, and reveal the effects of key parameters on performance of these cycles. It could be helpful to understand and develop a combined cycle coupled with a high temperature reactor in the future.

  13. Is proximity to alcohol outlets associated with alcohol consumption and alcohol-related harm in Denmark?

    DEFF Research Database (Denmark)

    Kedir, Abdu; Berg-Beckhoff, Gabriele; Stock, Christiane

    2018-01-01

    Background: This study examined the associations between distance from residence to the nearest alcohol outlet with alcohol consumption as well as with alcohol-related harm. Methods: Data on alcohol consumption, alcohol-related harm and sociodemographics were obtained from the 2011 Danish Drug...... and Alcohol Survey (n=5133) with respondents aged 15–79 years. The information on distances from residence to the nearest alcohol outlets was obtained from Statistics Denmark. Multiple logistic and linear regressions were used to examine the association between distances to outlets and alcohol consumption...... whereas alcohol-related harm was analysed using negative binomial regression. Results: Among women it was found that those living closer to alcohol outlets were more likely to report alcohol-related harm (p

  14. Is proximity to alcohol outlets associated with alcohol consumption and alcohol-related harm in Denmark?

    DEFF Research Database (Denmark)

    Seid, Abdu K.; Berg-Beckhoff, Gabriele; Stock, Christiane

    2018-01-01

    Background: This study examined the associations between distance from residence to the nearest alcohol outlet with alcohol consumption as well as with alcohol-related harm. Methods: Data on alcohol consumption, alcohol-related harm and sociodemographics were obtained from the 2011 Danish Drug...... and Alcohol Survey (n = 5133) with respondents aged 15–79 years. The information on distances from residence to the nearest alcohol outlets was obtained from Statistics Denmark. Multiple logistic and linear regressions were used to examine the association between distances to outlets and alcohol consumption...... whereas alcohol-related harm was analysed using negative binomial regression. Results: Among women it was found that those living closer to alcohol outlets were more likely to report alcohol-related harm (p

  15. Effect of flow configuration on moderator temperature distribution for 700 MWe Calandria

    International Nuclear Information System (INIS)

    Bharj, Jaspal Singh; Sahaya, R.R.; Dharne, S.P.

    2009-01-01

    The Calandria of a Pressurized Heavy Water Reactor (PHWR) is essentially a horizontal cylindrical vessel housing a matrix of horizontal tubes called Calandria tubes within which is contained the pressure tubes that house the fuel bundles. In addition there are horizontal and vertical flux control and shutdown devices. The Calandria is filled with heavy water moderator at a pressure slightly above the atmosphere. A large amount of heat (about 125 MWth) is generated within the moderator mainly due to neutron slowing down and attenuation of gamma radiations. This heat generation gives rise to a strong buoyancy-driven natural convection flow. In the proposed configuration of 700 MWe PHWR Calandria, moderator inlet diffusers are directed upwards and the outlet nozzles are at the bottom of the Calandria. The basis for the above said inlet/outlet configuration depends upon the various factors like space availability, NPSH requirement for the moderator pumps, and interference of flow with the other components inside the Calandria. This configuration is not conducive for the buoyancy-dominated flows generated due to large volumetric heat generation in the moderator. In order to see the effects of changes in flow configuration by re-orienting the inlet/outlet, a CFD study was undertaken for moderator flows in the conceptual Calandria. In the study, the moderator inlet diffusers direct the cool moderator towards the bottom of the Calandria and hot moderator flows out through the outlets in the upper half of the Calandria. The results of the study with various flow configurations show that modification in moderator flow configuration in Calandria, by way of introduction of moderator in the downward direction through diffusers and provision of the exits from the upper portion of the Calandria, results in significant reduction of the maximum temperature of moderator in Calandria. Further, the temperature distribution in the Calandria in the proposed configurations is much more

  16. Development of the temperature field at the WWER-440 core outlet monitoring system and application of the data analyses methods

    International Nuclear Information System (INIS)

    Spasova, V.; Georgieva, N.; Haralampieva, Tz.

    2001-01-01

    On-line internal reactor monitoring by 216 thermal couples, located at the reactor core outlet, is carried out during power operation of WWER-440 Units 1 and 2 at Kozloduy NPP. Automatic monitoring of technology process is performed by IB-500MA, which collects and performs initial data processing (discrediting and conversion of analogue signals into digital mode). The paper also presents the results and analyses of power distribution monitoring during the past 21-th and current 22-th fuel cycle at Kozloduy NPP, Unit 1 by using archiving system capacity and related software. The possibility to perform operational assessment and analysis of power distribution in the reactor core in each point of the fuel cycle is checked by comparison of the neutron-physical calculation results with reactor coolant system parameters. Paper shows that the processing and analysis of accumulated significant amount of data in the archive files increases accuracy and reliability of power distribution monitoring in the reactor core in each moment of the fuel cycle of WWER-440 reactors at Kozloduy NPP

  17. Numerical evaluation of flow through a prismatic very high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Barros Filho, Jose A.; Santos, Andre A.C.; Navarro, Moyses A.; Ribeiro, Felipe Lopes

    2011-01-01

    The High-temperature Gas-cooled reactor (HTGR) is a Next Generation Nuclear System that has a good chance to be used as energy generation source in the near future owing to its potential capacity to supply hydrogen without greenhouse gas emission for the future humanity. Recently, improvements in the HTGR design led to the Very High Temperature Reactor (VHTR) concept in which the outlet temperature of the coolant gas reaches to 1000 deg C increasing the efficiency of the hydrogen and electricity generation. Among the core concepts emerging in the VHTR development stands out the prismatic block which uses coated fuel microspheres named TRISO pressed into cylinders and assembled in hexagonal graphite blocks staked to form columns. The graphite blocks contain flow channels around the fuel cylinders for the helium coolant. In this study an analysis is performed using the CFD code CFX 13.0 on a prismatic fuel assembly in order to investigate its thermo-fluid dynamic performance. The simulations were made in a 1/12 fuel element model of the GT-MHR design which was developed by General Atomics. A numerical mesh verification process based on the Grid Convergence Index (GCI) was performed using five progressively refined meshes to assess the numerical uncertainty of the simulation and determine adequate mesh parameters. An analysis was also performed to evaluate different methods to define the inlet and outlet boundary conditions. In this study simulations of models with and without inlet and outlet plena were compared, showing that the presence of the plena offers a more realistic flow distribution. (author)

  18. A CLINICAL STUDY ON GASTRIC OUTLET OBSTRUCTION IN A SOUTH INDIAN TEACHING HOSPITAL

    Directory of Open Access Journals (Sweden)

    Sailaja

    2015-10-01

    Full Text Available Gastric outlet obstruction is defined as a clinical and patho - physiological consequence of any disease process that produces a mechanical impediment to gastric emptying which may be extrinsic or intrinsic. Gastric outlet obstruction can be a diagnostic and treatment dilemma. Endoscopy of upper gastrointestinal tract has been a sensitive and specific investigation to study the status of gastric outlet - the pylorus and has enabled early detection of lesions of both stomach a nd duodenum. We undertook a prospective clinical study regarding incidence, etiology, investigation and management of cases of Gastric outlet obstruction in adults in a period of three years. In our study the m ost common cause of GOO is Carcinoma stomach a ntral region 46.6% , duodenal ulcer 33.3% , corrosive acid ingestion sequel 8.3%, peri ampullary carcinoma 6.6%, Ca pancreas 3.3%% , cholangio Carcinoma 1.6%. Males are more commonly involved in a ratio of M: F=3:1. Surgical procedures done varied from defini tive resections to palliative bypass or feeding jejunostomy for enteral feeding

  19. Is there an association between home-tobacco outlet proximity and smoking status in Denmark?

    DEFF Research Database (Denmark)

    Berg-Beckhoff, Gabriele; K Seid, Abdu; Stock, Christiane

    2017-01-01

    and/or tobacco outlets on smoking habits for the first time in a population based survey in Denmark. Method: Data came from the 2011 Danish national alcohol and drug survey of the Centre for Alcohol and Drug Research of Aarhus University (response rate 64%) and registries of Statistics Denmark were...... between residing close to a tobacco outlet and the prevalence of current and previous smoking. However, no significant association was found between distance from residence to tobacco outlets and smoking habits. Discussion: The prevalence of current smokers (24%) is in accordance with the 2011 annual......Abstract It is well established that exposure to point-of-sale tobacco promotion or impulse purchases and access to and distance to tobacco outlets are related to youth and adult smoking. The aim of the present study was to examine the association of distance from residence to the nearest alcohol...

  20. Effects of inlet/outlet configurations on the electrostatic capture of airborne nanoparticles and viruses

    International Nuclear Information System (INIS)

    Jang, Jaesung; Akin, Demir; Bashir, Rashid

    2008-01-01

    Motivated by capture and detection of airborne biological agents in real time with a cantilever biosensor without introducing the agents into liquids, we present the effects of inlet/outlet configurations of a homemade particle collector on the electrostatic capture of airborne 100 nm diameter nanoparticles under swirling gas flows. This particle collector has three different inlet/outlet configurations: forward inlet/outlet (FO), backward inlet/outlet (BO) and straight inlet/outlet (SO) configurations. We also present the electrostatic capture of Vaccinia viruses using the same particle collector and compare these virus measurements with the nanoparticle cases. The most particles were collected in the FO configuration. The numbers of particles captured in the BO and SO configurations were close within their standard deviations. For all the three configurations tested, the number of particles captured in the center electrode C was much smaller than those captured in the other electrodes at a flow rate of 1.1 l min −1 and an applied potential of 2 kV. Using a commercial CFD code FLUENT, we also simulated the effects of the three inlet/outlet configurations on the particle capture in terms of particle trajectories, velocities and travel times. This simulation was in a good agreement with measurements that the FO configuration is the most favorable to particle capture among the tested configurations at a flow rate of 1.1 l min −1 . The effects of particle diameters on the capture will also be discussed. This collector can be used for real-time monitoring of bioaerosols along with cantilever biosensors

  1. Isolated Cervical Rib Fracture: A Rare Etiology of Thoracic Outlet Syndrome

    Directory of Open Access Journals (Sweden)

    Rayees Ahmad Dar

    2011-01-01

    Full Text Available Isolated fracture of a cervical rib is a very rare entity and usually presents as a painless swelling or as thoracic outlet syndrome. We describe a case of a 45-year-old woman with history of fall two months back. She presented with symptoms of neurogenic thoracic outlet syndrome for one month. Isolated left cervical rib fracture was documented on X-ray cervical spine. Her fractured cervical rib was resected through a supraclavicular approach, and symptoms resolved completely in the postoperative period.

  2. Supermarket and fast-food outlet exposure in Copenhagen: associations with socio-economic and demographic characteristics.

    Science.gov (United States)

    Svastisalee, Chalida M; Nordahl, Helene; Glümer, Charlotte; Holstein, Bjørn E; Powell, Lisa M; Due, Pernille

    2011-09-01

    To investigate whether exposure to fast-food outlets and supermarkets is socio-economically patterned in the city of Copenhagen. The study was based on a cross-sectional multivariate approach to examine the association between the number of fast-food outlets and supermarkets and neighbourhood-level socio-economic indicators. Food business addresses were obtained from commercial and public business locators and geocoded using a geographic information system for all neighbourhoods in the city of Copenhagen (n 400). The regression of counts of fast-food outlets and supermarkets v. indicators of socio-economic status (percentage of recent immigrants, percentage without a high-school diploma, percentage of the population under 35 years of age and average household income in Euros) was performed using negative binomial analysis. Copenhagen, Denmark. The unit of analysis was neighbourhood (n 400). In the fully adjusted models, income was not a significant predictor for supermarket exposure. However, neighbourhoods with low and mid-low income were associated with significantly fewer fast-food outlets. Using backwise deletion from the fully adjusted models, low income remained significantly associated with fast-food outlet exposure (rate ratio = 0·66-0·80) in the final model. In the city of Copenhagen, there was no evidence of spatial patterning of supermarkets by income. However, we detected a trend in the exposure to fast-food outlets, such that neighbourhoods in the lowest income quartile had fewer fast-food outlets than higher-income neighbourhoods. These findings have similarities with studies conducted in the UK, but not in the USA. The results suggest there may be socio-economic factors other than income associated with food exposure in Europe.

  3. A cross-sectional analysis of the relationship between tobacco and alcohol outlet density and neighbourhood deprivation.

    Science.gov (United States)

    Shortt, Niamh K; Tisch, Catherine; Pearce, Jamie; Mitchell, Richard; Richardson, Elizabeth A; Hill, Sarah; Collin, Jeff

    2015-10-05

    There is a strong socio-economic gradient in both tobacco-and alcohol-related harm. One possible factor contributing to this social gradient may be greater availability of tobacco and alcohol in more socially-deprived areas. A higher density of tobacco and alcohol outlets is not only likely to increase supply but also to raise awareness of tobacco/alcohol brands, create a competitive local market that reduces product costs, and influence local social norms relating to tobacco and alcohol consumption. This paper examines the association between the density of alcohol and tobacco outlets and neighbourhood-level income deprivation. Using a national tobacco retailer register and alcohol licensing data this paper calculates the density of alcohol and tobacco retail outlets per 10,000 population for small neighbourhoods across the whole of Scotland. Average outlet density was calculated for neighbourhoods grouped by their level of income deprivation. Associations between outlet density and deprivation were analysed using one way analysis of variance. There was a positive linear relationship between neighbourhood deprivation and outlets for both tobacco (p sales alcohol (p sales and on-sales alcohol outlets. The social gradient evident in alcohol and tobacco supply may be a contributing factor to the social gradient in alcohol- and tobacco-related disease. Policymakers should consider such gradients when creating tobacco and alcohol control policies. The potential contribution to public health, and health inequalities, of reducing the physical availability of both alcohol and tobacco products should be examined in developing broader supply-side interventions.

  4. A porcine model of bladder outlet obstruction incorporating radio-telemetered cystometry.

    Science.gov (United States)

    Shaw, Matthew B; Herndon, Claude D; Cain, Mark P; Rink, Richard C; Kaefer, Martin

    2007-07-01

    To present a novel porcine model of bladder outlet obstruction (BOO) with a standardized bladder outlet resistance and real-time ambulatory radio-telemetered cystometry, as BOO is a common condition with many causes in both adults and children, with significant morbidity and occasional mortality, but attempts to model this condition in many animal models have the fundamental problem of standardising the degree of outlet resistance. BOO was created in nine castrated male pigs by dividing the mid-urethra; outflow was allowed through an implanted bladder drainage catheter containing a resistance valve, allowing urine to flow across the valve only when a set pressure differential was generated across the valve. An implantable radio-telemetered pressure sensor monitored the pressure within the bladder and abdominal cavity, and relayed this information to a remote computer. Four control pigs had an occluded bladder drainage catheter and pressure sensor placed, but were allowed to void normally through the native urethra. Intra-vesical pressure was monitored by telemetry, while the resistance valve was increased weekly, beginning with 2 cmH2O and ultimately reaching 10 cmH2O. The pigs were assessed using conventional cystometry under anaesthesia before death, and samples conserved in formalin for haematoxylin and eosin staining. The pigs had radio-telemetered cystometry for a median of 26 days. All telemetry implants functioned well for the duration of the experiment, but one pig developed a urethral fistula and was excluded from the study. With BOO the bladder mass index (bladder mass/body mass x 10 000) increased from 9.7 to 20 (P = 0.004), with a significant degree of hypertrophy of the detrusor smooth muscle bundles. Obstructed bladders were significantly less compliant than control bladders (8.3 vs 22.1 mL/cmH2O, P = 0.03). Telemetric cystometry showed that there was no statistically significance difference in mean bladder pressure between obstructed and control pigs

  5. Supermarket and fast-food outlet exposure in Copenhagen

    DEFF Research Database (Denmark)

    Svastisalee, Chalida Mae; Jensen, Helene Nordahl; Glumer, Charlotte

    2011-01-01

    and neighbourhood-level socio-economic indicators. Food business addresses were obtained from commercial and public business locators and geocoded using a geographic information system for all neighbourhoods in the city of Copenhagen (n 400). The regression of counts of fast-food outlets and supermarkets v...

  6. Gastrojejunostomy for gastric outlet obstruction in patients with ...

    African Journals Online (AJOL)

    Sixty patients were discharged from hospital having resumed normal eating. Their median survival after surgery was 9 months. Conclusion. Gastrojejunostomy offers worthwhile palliation and may prolong survival in a significant group of patients with irresectable gastric carcinoma and gastric outlet obstruction. South African ...

  7. Does neighborhood fast-food outlet exposure amplify inequalities in diet and obesity? A cross-sectional study.

    Science.gov (United States)

    Burgoine, Thomas; Forouhi, Nita G; Griffin, Simon J; Brage, Søren; Wareham, Nicholas J; Monsivais, Pablo

    2016-06-01

    Greater exposures to fast-food outlets and lower levels of education are independently associated with less healthy diets and obesity. Little is known about the interplay between these environmental and individual factors. The purpose of this study was to test whether observed differences in fast-food consumption and obesity by fast-food outlet exposure are moderated by educational attainment. In a population-based cohort of 5958 adults aged 29-62 y in Cambridgeshire, United Kingdom, we used educational attainment-stratified regression models to estimate the food-frequency questionnaire-derived consumption of energy-dense "fast foods" (g/d) typically sold in fast-food restaurants and measured body mass index (BMI; in kg/m(2)) across geographic information system-derived home and work fast-food exposure quartiles. We used logistic regression to estimate the odds of obesity (BMI ≥30) and calculated relative excess risk due to interaction (RERI) on an additive scale. Participant data were collected during 2005-2013 and analyzed in 2015. Greater fast-food consumption, BMI, and odds of obesity were associated with greater fast-food outlet exposure and a lower educational level. Fast-food consumption and BMI were significantly different across education groups at all levels of fast-food outlet exposure (P fast-food outlet exposure amplified differences in fast-food consumption across levels of education. The relation between fast-food outlet exposure and obesity was only significant among those who were least educated (OR: 2.05; 95% CI: 1.08, 3.87; RERI = 0.88), which suggested a positive additive interaction between education and fast-food outlet exposure. These findings suggest that efforts to improve diets and health through neighborhood-level fast-food outlet regulation might be effective across socioeconomic groups and may serve to reduce observed socioeconomic inequalities in diet and obesity.

  8. Shopper Loyalty to Whom? Chain Versus Outlet Loyalty in the Context of Store Acquisitions

    NARCIS (Netherlands)

    van Lin, Arjen; Gijsbrechts, E.

    2014-01-01

    When patronizing stores, consumers may exhibit loyalty not only to a retail chain but also to a specific outlet. This distinction is important in a dynamic retail environment: if a store changes ownership, chain loyalty makes customers inclined to seek out another outlet of the former chain, whereas

  9. Shopper loyalty to whom? Chain versus outlet loyalty in the context of store acquisitions

    NARCIS (Netherlands)

    van Lin, A.I.J.G.; Gijsbrechts, E.

    When patronizing stores, consumers may exhibit loyalty not only to a retail chain but also to a specific outlet. This distinction is important in a dynamic retail environment: if a store changes ownership, chain loyalty makes customers inclined to seek out another outlet of the former chain, whereas

  10. Engineering geology model of the Crater Lake outlet, Mt. Ruapehu, New Zealand, to inform rim breakout hazard

    Science.gov (United States)

    Cook, Stefan C. W.; Kennedy, Ben M.; Villeneuve, Marlène C.

    2018-01-01

    Mt. Ruapehu, in the central North Island of New Zealand, hosts a hot acidic Crater Lake over the active volcanic vent with a surface elevation of c. 2530 m.a.s.l. Volcanic activity and other montane processes have previously resulted in catastrophic releases of some or all of the c. 10 Mm3 of water retained in the lake, creating serious hazards downstream. A major lahar in March 2007 exposed a 10 m high face representative of the rock units impounding the lake, providing an opportunity to conduct both field and laboratory analysis to characterise the rock mass conditions at the outlet to assess the stability of the outlet area. This paper presents an engineering geology model of Crater Lake outlet. Our model shows three andesitic geological units at the outlet, each with different geological histories and physical and mechanical properties, which impact its stability. Geotechnical methods used to characterise the outlet include laboratory testing of the strength, stiffness, porosity and unit weight, and field-based rock mass characterisation using the geological strength index (GSI) and rock mass rating (RMR). Field observations, geomorphology mapping, historic and contemporary photographs, and laboratory results are combined to create cross sections that provide key information for establishing the engineering geology model. The units are recognised in what is informally termed the Crater Lake Formation: i) The upper surface layer is a c. 2 m thick sub-horizontal dark grey lava unit (Armoured Lava Ledge) with sub-horizontal cooling joints spaced at 0.2 m to 2.0 m intervals. The intact rock has a porosity range of 15-27%, density range of 1723-2101 kg/m3, GSI range of 45-75, and unconfined compressive strength (UCS) range of 19-48 MPa. ii) Below this, and outcropping down the majority of the outlet waterfall is a poorly sorted breccia unit composed of block and matrix material (Lava Breccia). The blocks range from 0.1 m to 0.8 m in diameter with an average porosity

  11. A temporal analysis of the spatial clustering of food outlets around schools in Christchurch, New Zealand, 1966 to 2006.

    Science.gov (United States)

    Day, Peter L; Pearce, Jamie R; Pearson, Amber L

    2015-01-01

    To explore changes in urban food environments near schools, as potential contributors to the rising prevalence of overweight and obesity among children. Addresses of food premises and schools in 1966, 1976, 1986, 1996 and 2006 were geo-coded. For each year, the number and proportion of outlets by category (supermarket/grocery; convenience; fast-food outlet) within 800 m of schools were calculated. The degree of spatial clustering of outlets was assessed using a bivariate K-function analysis. Food outlet categories, school level and school social deprivation quintiles were compared. Christchurch, New Zealand. All schools and food outlets at 10-year snapshots from 1966 to 2006. Between 1966 and 2006, the median number of supermarkets/grocery stores within 800 m of schools decreased from 5 to 1, convenience stores decreased from 2 to 1, and fast-food outlets increased from 1 to 4. The ratio of fast-food outlets to total outlets increased from 0·10 to 0·67. The clustering of fast-food outlets was greatest within 800 m of schools and around the most socially deprived schools. Over the 40-year study period, school food environments in Christchurch can be characterized by increased densities of fast-food outlets within walking distance of schools, especially around the most deprived schools. Since the 1960s, there have been substantial changes to the food environments around schools which may increasingly facilitate away-from-home food consumption for children and provide easily accessible, cheap energy-dense foods, a recognized contributor to the rise in prevalence of overweight and obesity among young people.

  12. Determination of temperature measurements uncertainties of the heat transport primary system of Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Pomerantz, Marcelo E.; Coutsiers, Eduardo E.; Moreno, Carlos A.

    1999-01-01

    In this work, the systematic errors in temperature measurements in inlet and outlet headers of HTPS coolant channels of Embalse nuclear power plant are evaluated. These uncertainties are necessary for a later evaluation of the channel power maps transferred to the coolant. The power maps calculated in this way are used to compare power distributions using neutronic codes. Therefore, a methodology to correct systematic errors of temperature in outlet feeders and inlet headers is developed in this work. (author)

  13. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...

  14. Local concentration of fast-food outlets is associated with poor nutrition and obesity.

    Science.gov (United States)

    Kruger, Daniel J; Greenberg, Emily; Murphy, Jillian B; DiFazio, Lindsay A; Youra, Kathryn R

    2014-01-01

    We investigated the relationship of the local availability of fast-food restaurant locations with diet and obesity. We geocoded addresses of survey respondents and fast-food restaurant locations to assess the association between the local concentration of fast-food outlets, BMI, and fruit and vegetable consumption. The survey was conducted in Genesee County, Michigan. There were 1345 individuals included in this analysis, and the response rate was 25%. The Speak to Your Health! Community Survey included fruit and vegetable consumption items from the Behavioral Risk Factor Surveillance System, height, weight, and demographics. We used ArcGIS to map fast-food outlets and survey respondents. Stepwise linear regressions identified unique predictors of body mass index (BMI) and fruit and vegetable consumption. Survey respondents had 8 ± 7 fast-food outlets within 2 miles of their home. Individuals living in close proximity to fast-food restaurants had higher BMIs t(1342) = 3.21, p food availability, which may constrain the success of nutrition promotion efforts. Efforts to decrease the local availability of unhealthy foods as well as programs to help consumers identify strategies for obtaining healthy meals at fast-food outlets may improve health outcomes.

  15. Parametric Evaluation of Large-Scale High-Temperature Electrolysis Hydrogen Production Using Different Advanced Nuclear Reactor Heat Sources

    International Nuclear Information System (INIS)

    Harvego, Edwin A.; McKellar, Michael G.; O'Brien, James E.; Herring, J. Stephen

    2009-01-01

    High Temperature Electrolysis (HTE), when coupled to an advanced nuclear reactor capable of operating at reactor outlet temperatures of 800 C to 950 C, has the potential to efficiently produce the large quantities of hydrogen needed to meet future energy and transportation needs. To evaluate the potential benefits of nuclear-driven hydrogen production, the UniSim process analysis software was used to evaluate different reactor concepts coupled to a reference HTE process design concept. The reference HTE concept included an Intermediate Heat Exchanger and intermediate helium loop to separate the reactor primary system from the HTE process loops and additional heat exchangers to transfer reactor heat from the intermediate loop to the HTE process loops. The two process loops consisted of the water/steam loop feeding the cathode side of a HTE electrolysis stack, and the sweep gas loop used to remove oxygen from the anode side. The UniSim model of the process loops included pumps to circulate the working fluids and heat exchangers to recover heat from the oxygen and hydrogen product streams to improve the overall hydrogen production efficiencies. The reference HTE process loop model was coupled to separate UniSim models developed for three different advanced reactor concepts (a high-temperature helium cooled reactor concept and two different supercritical CO2 reactor concepts). Sensitivity studies were then performed to evaluate the affect of reactor outlet temperature on the power cycle efficiency and overall hydrogen production efficiency for each of the reactor power cycles. The results of these sensitivity studies showed that overall power cycle and hydrogen production efficiencies increased with reactor outlet temperature, but the power cycles producing the highest efficiencies varied depending on the temperature range considered

  16. Communicating Ebola through social media and electronic news media outlets: A cross-sectional study.

    Science.gov (United States)

    Househ, Mowafa

    2016-09-01

    Social media and electronic news media activity are an important source of information for the general public. Yet, there is a dearth of research exploring the use of Twitter and electronic news outlets during significant worldly events such as the recent Ebola Virus scare. The purpose of this article is to investigate the use of Twitter and electronic news media outlets in communicating Ebola Virus information. A cross-sectional survey of Twitter data and Google News Trend data from 30 September till 29 October, 2014 was conducted. Between 30 September and 29 October, there were approximately 26 million tweets (25,925,152) that contained the word Ebola. The highest number of correlated activity for Twitter and electronic news outlets occurred on 16 October 2014. Other important peaks in Twitter data occurred on 1 October, 6 October, 8 October, and 12 October, 2014. The main influencers of the Twitter feeds were news media outlets. The study reveals a relationship between electronic news media publishing and Twitter activity around significant events such as Ebola. Healthcare organizations should take advantage of the relationship between electronic news media and trending events on social media sites such as Twitter and should work on developing social media campaigns in co-operation with leading electronic news media outlets (e.g. CNN, Yahoo, Reuters) that can have an influence on social media activity. © The Author(s) 2015.

  17. Temperature and flow fluctuations under local boiling in a simulated fuel subassembly

    International Nuclear Information System (INIS)

    Inujima, H.; Ogino, T.; Uotani, M.; Yamaguchi, K.

    1980-08-01

    Out-of-pile experiments were carried out with the sodium test loop SIENA in O-arai Engineering Center of PNC, and the feasibility studies had been made on the local boiling detection by use of temperature and flow fluctuations. The studies showed that the temperature fluctuation transferred the information on local boiling toward the end of the bundle, but hardly to the outlet. In addition, it was proved that the anomaly detection method, which used the algorithm of whiteness test method to the residual time series data of autoregressive model, is an effective one for detecting anomaly such as local boiling. (author)

  18. Damage distribution and remnant life assessment of a super-heater outlet header used for long time

    Energy Technology Data Exchange (ETDEWEB)

    Hiroyuki, Okamura [Science Univ. of Tokyo (Japan); Ryuichi, Ohotani [Kyoto Univ. (Japan); Kazuya, Fujii [Japan Power Engineering and Inspection Corp., Tokyo (Japan); Masashi, Nakashiro; Fumio, Takemasa; Hideo, Umaki; Tomiyasu, Masumura [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    1998-11-01

    This paper presents the results of investigation on evaluating damage distribution to base metals and welded joints in the thickness direction and evaluate damage on ligaments. Thick wall tested sample was the superheater outlet header component long term serviced in high pressure and temperature condition in thermal power plant. The simulate unused steel of component material was made from sample by suitable heat treatment, and the extent of damage was assessed based on a comparison of nondestructive and destructive test results between simulate unused and aged samples. Damage evaluation was also made by FEM structural stress analysis. (orig./MM)

  19. “Clavicular duplication causing thoracic outlet obstruction”: Unique ...

    African Journals Online (AJOL)

    A 22‑year‑old female student reported with features of neurogenic thoracic outlet syndrome mainly involving C8‑T1 components of the brachial plexus, seemingly originating from involvement in costo‑clavicular space. Radiograph of the shoulder revealed clavicular duplication. Neuro‑physiological studies corroborated the ...

  20. Pemilihan food outlet sebagai faktor risiko berat badan lebih anak usia sekolah dasar di Kecamatan Tegalsari Surabaya

    Directory of Open Access Journals (Sweden)

    Renny Evelyn Hartono

    2016-08-01

    Full Text Available ABSTRACTIntroduction: Overweight and obesity are conditions resulting from an imbalance of calories in the body that occur in a long time and cause more deaths than underweight. One of factors related is food pattern, which also infl uenced the selection of food outlets. Surabaya is an urban area so it has many types and characteristic s of food outlet. Elementary school (4, 5, 6 do not really depend on their parents, so their food consumption and physical activity began to vary. Objectives: To identify the relationship between the selection of food outlets and overweight/obesity status of elementary school in Tegalsari district, Surabaya.Methods: This research used a case-control study design. Samples were 51 children for each group of cases and control and obtained from 11 primary school in the 5 subdistricts in Tegalsari district, Surabaya. Data were obtained by interview, direct observation of food outlets, and interview to select informants about the reasons of selecting food outlets . Quantitative data were processed by bivariate (chi-square and multivariate (binomial regression test. Results: Bivariate test results showed that there were signifi cant relationships between the frequency to the street vendors consumption (OR=4.09, 95% CI:1.60-10.75, frequency of fast food consumption (OR=2.86, 95% CI:1.19-6.94 and snacks (OR=6,05, 95% CI:2.20-17.62, physical activity (OR=3.09, 95% CI:1.28-7.51 and gender (OR=2.70, 95% CI:1.11-6.64 with overweight/obesity status, while frequency of stores (total, supermarket, market, mini-market, frequency of food service place (total, restaurants, fast food restaurants, frequency of vegetable and fruit consumption, and socio-economic status of respondents did not relate signifi cantly. In multivariate analysis, the variables that affected frequency of the street vendors were snack consumption, physical activity, sex and total expenditure. Conclusions: Frequency of the street vendors, fast food consumption

  1. Bacteriological Analysis and Hygine Level of Food Outlets within Rufus Giwa Polytechnic, Owo, Ondo State, Nigeria.

    OpenAIRE

    Ibrahim TA; Akenroye OM; Osabiya OJ

    2013-01-01

    The bacteriological quality of three major food outlets in Rufus Giwa Polytechnic, Owo, was assessed using standard bacteriological methods. Swabs of hands of food vendors, table and plates in these outlets were assessed for total bacterial count, total coliform count and total E. coli count. A total of 789 bacterial colonies were isolated from hands of food handlers, tables and plates used for eating in the outlets. Eleven genera of bacteria were isolated and identified, they were; klebsiell...

  2. Change in alcohol outlet density and alcohol-related harm to population health (CHALICE

    Directory of Open Access Journals (Sweden)

    Fone David

    2012-06-01

    Full Text Available Abstract Background Excess alcohol consumption has serious adverse effects on health and violence-related harm. In the UK around 37% of men and 29% of women drink to excess and 20% and 13% report binge drinking. The potential impact on population health from a reduction in consumption is considerable. One proposed method to reduce consumption is to reduce availability through controls on alcohol outlet density. In this study we investigate the impact of a change in the density of alcohol outlets on alcohol consumption and alcohol-related harms to health in the community. Methods/Design A natural experiment of the effect of change in outlet density between 2005–09, in Wales, UK; population 2.4 million aged 16 years and over. Data on outlets are held by the 22 local authorities in Wales under The Licensing Act 2003. The study outcomes are change in (1 alcohol consumption using data from annual Welsh Health Surveys, (2 alcohol-related hospital admissions using the Patient Episode Database for Wales, (3 Accident & Emergency department attendances between midnight–6am, and (4 alcohol-related violent crime against the person, using Police data. The data will be anonymously record-linked within the Secure Anonymised Information Linkage Databank at individual and 2001 Census Lower Super Output Area levels. New methods of network analysis will be used to estimate outlet density. Longitudinal statistical analysis will use (1 multilevel ordinal models of consumption and logistic models of admissions and Accident & Emergency attendance as a function of change in individual outlet exposure, adjusting for confounding variables, and (2 spatial models of the change in counts/rates of each outcome measure and outlet density. We will assess the impact on health inequalities and will correct for population migration. Discussion This inter-disciplinary study requires expertise in epidemiology and public health, health informatics, medical statistics

  3. Malignant gastric outlet obstruction managed by endoscopic stenting: a prospective single-centre study

    DEFF Research Database (Denmark)

    Havemann, Maria Cecilie; Adamsen, Sven; Wøjdemann, Morten

    2008-01-01

    -to-treat principle. All patients were offered endoscopic stenting. Oral intake before and after stenting was assessed using the gastric outlet obstruction score system (GOOSS). Various lengths of duodenal Hanaro(R) self-expanding nitinol stents were delivered through a therapeutic endoscope. Outcome criteria were......Objective. Endoscopic stenting for malignant gastric outlet obstruction was chosen as the primary strategy by which to palliate this complication, which is dominated by weight loss and anorexia. Advanced upper gastrointestinal tract cancers present late and life expectancy is limited. Only smaller...... multicentre studies point to endoscopic stenting as superior to surgery in terms of clinical outcome and cost. Material and methods. Forty-five consecutive patients with gastric outlet obstruction as a result of advanced upper GI-tract malignancy were enrolled in accordance with the intention...

  4. Calculation of gas temperature at the outlet of the combustion chamber and in the air-gas channel of a gas-turbine unit by data of acceptance tests in accordance with ISO

    Science.gov (United States)

    Kostyuk, A. G.; Karpunin, A. P.

    2016-01-01

    This article describes a high accuracy method enabling performance of the calculation of real values of the initial temperature of a gas turbine unit (GTU), i.e., the gas temperature at the outlet of the combustion chamber, in a situation where manufacturers do not disclose this information. The features of the definition of the initial temperature of the GTU according to ISO standards were analyzed. It is noted that the true temperatures for high-temperature GTUs is significantly higher than values determined according to ISO standards. A computational procedure for the determination of gas temperatures in the air-gas channel of the gas turbine and cooling air consumptions over blade rims is proposed. As starting equations, the heat balance equation and the flow mixing equation for the combustion chamber are assumed. Results of acceptance GTU tests according to ISO standards and statistical dependencies of required cooling air consumptions on the gas temperature and the blade metal are also used for calculations. An example of the calculation is given for one of the units. Using a developed computer program, the temperatures in the air-gas channel of certain GTUs are calculated, taking into account their design features. These calculations are performed on the previously published procedure for the detailed calculation of the cooled gas turbine subject to additional losses arising because of the presence of the cooling system. The accuracy of calculations by the computer program is confirmed by conducting verification calculations for the GTU of the Mitsubishi Comp. and comparing results with published data of the company. Calculation data for temperatures were compared with the experimental data and the characteristics of the GTU, and the error of the proposed method is estimated.

  5. Catchment power and the joint distribution of elevation and travel distance to the outlet

    Directory of Open Access Journals (Sweden)

    L. S. Sklar

    2016-10-01

    Full Text Available The delivery of water, sediment, and solutes by catchments is influenced by the distribution of source elevations and their travel distances to the outlet. For example, elevation affects the magnitude and phase of precipitation, as well as the climatic factors that govern rock weathering, which influence the production rate and initial particle size of sediments. Travel distance, in turn, affects the timing of flood peaks at the outlet and the degree of sediment size reduction by wear, which affects particle size distributions at the outlet. The distributions of elevation and travel distance have been studied extensively but separately, as the hypsometric curve and width function. Yet a catchment can be considered as a collection of points, each with paired values of elevation and travel distance. For every point, the ratio of elevation to travel distance defines the mean slope for transport of mass to the outlet. Recognizing that mean slope is proportional to the average rate of loss of potential energy by water and sediment during transport to the outlet, we use the joint distribution of elevation and travel distance to define two new metrics for catchment geometry: "source-area power", and the corresponding catchment-wide integral "catchment power". We explore patterns in source-area and catchment power across three study catchments spanning a range of relief and drainage area. We then develop an empirical algorithm for generating synthetic source-area power distributions, which can be parameterized with data from natural catchments. This new way of quantifying the three-dimensional geometry of catchments can be used to explore the effects of topography on the distribution on fluxes of water, sediment, isotopes, and other landscape products passing through catchment outlets, and may provide a fresh perspective on problems of both practical and theoretical interest.

  6. Surf zone entrainment, along-shore transport, and human health implications of pollution from tidal outlets

    Science.gov (United States)

    Grant, S. B.; Kim, J. H.; Jones, B. H.; Jenkins, S. A.; Wasyl, J.; Cudaback, C.

    2005-10-01

    Field experiments and modeling studies were carried out to characterize the surf zone entrainment and along-shore transport of pollution from two tidal outlets that drain into Huntington Beach and Newport Beach, popular public beaches in southern California. The surf zone entrainment and near-shore transport of pollutants from these tidal outlets appears to be controlled by prevailing wave conditions and coastal currents, and fine-scale features of the flow field around the outlets. An analysis of data from dye experiments and fecal indicator bacteria monitoring studies reveals that the along-shore flux of surf zone water is at least 50 to 300 times larger than the cross-shore flux of surf zone water. As a result, pollutants entrained in the surf zone hug the shore, where they travel significant distances parallel to the beach before diluting to extinction. Under the assumption that all surf zone pollution at Huntington Beach originates from two tidal outlets, the Santa Ana River and Talbert Marsh outlets, models of mass and momentum transport in the surf zone approximately capture the observed tidal phasing and magnitude of certain fecal indicator bacteria groups (total coliform) but not others (Escherichia coli and enterococci), implying the existence of multiple sources of, and/or multiple transport pathways for, fecal pollution at this site. The intersection of human recreation and near-shore pollution pathways implies that, from a human health perspective, special care should be taken to reduce the discharge of harmful pollutants from land-side sources of surface water runoff, such as tidal outlets and storm drains.

  7. Statistical Approaches Used to Assess the Equity of Access to Food Outlets: A Systematic Review.

    Science.gov (United States)

    Lamb, Karen E; Thornton, Lukar E; Cerin, Ester; Ball, Kylie

    2015-01-01

    Inequalities in eating behaviours are often linked to the types of food retailers accessible in neighbourhood environments. Numerous studies have aimed to identify if access to healthy and unhealthy food retailers is socioeconomically patterned across neighbourhoods, and thus a potential risk factor for dietary inequalities. Existing reviews have examined differences between methodologies, particularly focussing on neighbourhood and food outlet access measure definitions. However, no review has informatively discussed the suitability of the statistical methodologies employed; a key issue determining the validity of study findings. Our aim was to examine the suitability of statistical approaches adopted in these analyses. Searches were conducted for articles published from 2000-2014. Eligible studies included objective measures of the neighbourhood food environment and neighbourhood-level socio-economic status, with a statistical analysis of the association between food outlet access and socio-economic status. Fifty-four papers were included. Outlet accessibility was typically defined as the distance to the nearest outlet from the neighbourhood centroid, or as the number of food outlets within a neighbourhood (or buffer). To assess if these measures were linked to neighbourhood disadvantage, common statistical methods included ANOVA, correlation, and Poisson or negative binomial regression. Although all studies involved spatial data, few considered spatial analysis techniques or spatial autocorrelation. With advances in GIS software, sophisticated measures of neighbourhood outlet accessibility can be considered. However, approaches to statistical analysis often appear less sophisticated. Care should be taken to consider assumptions underlying the analysis and the possibility of spatially correlated residuals which could affect the results.

  8. Statistical Approaches Used to Assess the Equity of Access to Food Outlets: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Karen E. Lamb

    2015-07-01

    Full Text Available BackgroundInequalities in eating behaviours are often linked to the types of food retailers accessible in neighbourhood environments. Numerous studies have aimed to identify if access to healthy and unhealthy food retailers is socioeconomically patterned across neighbourhoods, and thus a potential risk factor for dietary inequalities. Existing reviews have examined differences between methodologies, particularly focussing on neighbourhood and food outlet access measure definitions. However, no review has informatively discussed the suitability of the statistical methodologies employed; a key issue determining the validity of study findings. Our aim was to examine the suitability of statistical approaches adopted in these analyses.MethodsSearches were conducted for articles published from 2000-2014. Eligible studies included objective measures of the neighbourhood food environment and neighbourhood-level socio-economic status, with a statistical analysis of the association between food outlet access and socio-economic status.ResultsFifty-four papers were included. Outlet accessibility was typically defined as the distance to the nearest outlet from the neighbourhood centroid, or as the number of food outlets within a neighbourhood (or buffer. To assess if these measures were linked to neighbourhood disadvantage, common statistical methods included ANOVA, correlation, and Poisson or negative binomial regression. Although all studies involved spatial data, few considered spatial analysis techniques or spatial autocorrelation.ConclusionsWith advances in GIS software, sophisticated measures of neighbourhood outlet accessibility can be considered. However, approaches to statistical analysis often appear less sophisticated. Care should be taken to consider assumptions underlying the analysis and the possibility of spatially correlated residuals which could affect the results.

  9. Transvaginal Mesh and Transanal Resection to Treat Outlet Obstruction Constipation Caused by Rectocele

    OpenAIRE

    Shi, Yang; Yu, Yongjun; Zhang, Xipeng; Li, Yuwei

    2017-01-01

    Background The aim of this study was to evaluate the curative effect of transvaginal mesh repair (TVMR) and stapled transanal rectal resection (STARR) in treating outlet obstruction constipation caused by rectocele. Material/Methods Patients who had outlet obstruction constipation caused by rectocele were retrospectively analyzed and 39 patients were enrolled the study. Patients were assigned to either the TVMR or STARR group. Postoperative factors such as complications, pain, recurrence rate...

  10. CFD Analysis on a Core Outlet Flow through the Fuel Alignment Plant of SMART

    International Nuclear Information System (INIS)

    Kim, Y. I.; Bae, Y. M.; Kim, K. K.

    2014-01-01

    CFD (Computational Fluid Dynamics) simulations were performed to confirm the core flow distribution for SMART, which acquired standard design approval in 2012. In this paper, CFD simulation is also used to calculate the pressure distribution of a core outlet, a Fuel Alignment Plate (FAP), for SMART. In SMART, the fluid discharged from the Steam Generator comes into a Flow Mixing Header Assembly (FMHA), and is rearranged and split into a very fine size. The FMHA is greatly important for enhancing the flow distribution of a downcomer during a normal operation, transient, and even accidents. Then, the fluid discharged from the FMHA flows into the core upstream through flow skirt holes. The Low Core Support Plate (LCSP) reallocates the flow introducing into the inlet core from the core upstream. The deviation of flow distribution becomes smaller or almost disappears by LCSP holes having relatively large loss coefficient compared to the downstream flow deviation. In an open core, the flow deviation at the core inlet region is diminished by cross flow as it goes upward. Near the core outlet, the flow distribution can be distorted by the influence of a Fuel Alignment Plate (FAP) installed above the fuels. In this paper, the effect of the core outlet flow structure such as the FAP holes of SMART is investigated. Before the calculation, the influences of mesh size and turbulence models are inspected. CFD simulations were performed to investigate the effect of FAP flow holes on the core outlet flow of SMART. As a preliminary study, the dependency of the mesh size and turbulence models was tested; a fine grid was applied, the effect of which is negligible, and the core outlet flow is not sensitive to the turbulence models. In brief, the flow resistance of FAP is less than 15% of that of the fuel assemblies. The flow resistance deviation between two flow path patterns is less than 1% of that of active core. Even two flow path patterns located at the downstream location of the

  11. Does neighborhood fast-food outlet exposure amplify inequalities in diet and obesity? A cross-sectional study12

    Science.gov (United States)

    Forouhi, Nita G; Griffin, Simon J; Brage, Søren; Wareham, Nicholas J

    2016-01-01

    Background: Greater exposures to fast-food outlets and lower levels of education are independently associated with less healthy diets and obesity. Little is known about the interplay between these environmental and individual factors. Objective: The purpose of this study was to test whether observed differences in fast-food consumption and obesity by fast-food outlet exposure are moderated by educational attainment. Design: In a population-based cohort of 5958 adults aged 29–62 y in Cambridgeshire, United Kingdom, we used educational attainment–stratified regression models to estimate the food-frequency questionnaire–derived consumption of energy-dense “fast foods” (g/d) typically sold in fast-food restaurants and measured body mass index (BMI; in kg/m2) across geographic information system–derived home and work fast-food exposure quartiles. We used logistic regression to estimate the odds of obesity (BMI ≥30) and calculated relative excess risk due to interaction (RERI) on an additive scale. Participant data were collected during 2005–2013 and analyzed in 2015. Results: Greater fast-food consumption, BMI, and odds of obesity were associated with greater fast-food outlet exposure and a lower educational level. Fast-food consumption and BMI were significantly different across education groups at all levels of fast-food outlet exposure (P fast-food outlet exposure amplified differences in fast-food consumption across levels of education. The relation between fast-food outlet exposure and obesity was only significant among those who were least educated (OR: 2.05; 95% CI: 1.08, 3.87; RERI = 0.88), which suggested a positive additive interaction between education and fast-food outlet exposure. Conclusion: These findings suggest that efforts to improve diets and health through neighborhood-level fast-food outlet regulation might be effective across socioeconomic groups and may serve to reduce observed socioeconomic inequalities in diet and obesity. PMID

  12. Boundary conditions for free surface inlet and outlet problems

    KAUST Repository

    Taroni, M.; Breward, C. J. W.; Howell, P. D.; Oliver, J. M.

    2012-01-01

    We investigate and compare the boundary conditions that are to be applied to free-surface problems involving inlet and outlets of Newtonian fluid, typically found in coating processes. The flux of fluid is a priori known at an inlet, but unknown

  13. Temperature field downstream of an heated bundle mock-up results for different power distribution

    International Nuclear Information System (INIS)

    Girard, J.P.; Buravand, Y.

    1982-10-01

    The aim of these peculiar experiments performed on the ML4 loop in ISPRA is to evaluate the characteristics of the temperature field over a length of 20 to 30 dias downstream of a rod bundle for different temperatures profiles at the bundle outlet. The final purpose of this work will be to establish either directly or through models whether it is possible or not to detect subassembly failures using suitable of the subassembly outlet temperature signal. 15 hours of digital and analog recording were taped for five different power distributions in the bundle. The total power dissipation remained constant during the whole run. Two flow rates and seven axial location were investigated. It is shown that the different temperature profiles produce slight differences in the variance and skewness of the temperature signal measured along the axis of the pipe over 20 dias

  14. Fruit and Vegetable Intake in Adolescents: Association with Socioeconomic Status and Exposure to Supermarkets and Fast Food Outlets

    Directory of Open Access Journals (Sweden)

    Chalida M. Svastisalee

    2012-01-01

    Full Text Available Background. We investigated differences in family social class associations between food outlet exposure and fruit and vegetable intake. Methods. We supplemented data from the 2006 Health Behavior in School Aged Children Study (n=6,096 with geocoded food outlet information surrounding schools (n=80. We used multilevel logistic regression to examine associations between infrequent fruit and vegetable intake and supermarket and fast food outlet concentration, stratified by family social class. Results. Boys and older children were most likely to eat fruit and vegetables infrequently. High fast food outlet exposure was marginally significant for low fruit intake in low social class children only. Children from middle and low social class backgrounds attending schools with combined high fast food outlet/low supermarket exposure were most likely to report infrequent fruit intake (ORlow=1.60; CI:  1.02–2.45; ORmid=1.40; CI:  1.03–190. Children from low social class backgrounds were also likely to report infrequent vegetable intake, given low supermarket and high fast food outlet exposure (OR=1.79; CI:  0.99–3.21. Conclusion. Our findings suggest social class modifies the relationship between intake and food outlet concentration. School interventions improving fruit and vegetable intake should consider neighborhood surroundings, targetting older children from low social class backgrounds.

  15. The impact of the tobacco retail outlet environment on adult cessation and differences by neighborhood poverty.

    Science.gov (United States)

    Cantrell, Jennifer; Anesetti-Rothermel, Andrew; Pearson, Jennifer L; Xiao, Haijun; Vallone, Donna; Kirchner, Thomas R

    2015-01-01

    This study examined the impact of tobacco retail outlets on cessation outcomes over time among non-treatment-seeking smokers and assessed differences by neighborhood poverty and individual factors. Observational longitudinal cohort study using geospatial data. We used generalized estimating equations to examine cessation outcomes in relation to the proximity and density of tobacco retail outlets near the home. Eight large Designated Media Areas across the United States. A total of 2377 baseline smokers followed over three waves from 2008 to 2010. Outlet addresses were identified through North American Industry Classification System codes and proximity and density measures were constructed for each participant at each wave. Outcomes included past 30-day abstinence and pro-cessation attitudes. Smokers in high poverty census tracts living between 500 m and 1.9 km from an outlet were over two times more likely to be abstinent than those living fewer than 500 m from an outlet (P < 0.05). Density within 500 m of home was associated with reduced abstinence [odds ratio (OR) = 0.94; confidence interval (CI) = 0.90, 0.98) and lower pro-cessation attitudes (Coeff = -0.07, CI = -0.10, -0.03) only in high poverty areas. In low poverty areas, density within 500 m was associated with greater pro-cessation attitudes (OR = 0.06; CI = 0.01, 0.12). Gender, education and heaviness of smoking did not moderate the impact of outlet proximity and density on cessation outcomes. In the United States, density of tobacco outlets within 500 m of the home residence appears to be negatively associated with smoking abstinence and pro-cessation attitudes only in poor areas. © 2014 Society for the Study of Addiction.

  16. Coolant mixing in LMFBR rod bundles and outlet plenum mixing transients. Final report

    International Nuclear Information System (INIS)

    Todreas, N.E.; Cheng, S.K.; Basehore, K.

    1984-08-01

    This project principally undertook the investigation of the thermal hydraulic performance of wire wrapped fuel bundles of LMFBR configuration. Results obtained included phenomenological models for friction factors, flow split and mixing characteristics; correlations for predicting these characteristics suitable for insertion in design codes; numerical codes for analyzing bundle behavior both of the lumped subchannel and distributed parameter categories and experimental techniques for pressure velocity, flow split, salt conductivity and temperature measurement in water cooled mockups of bundles and subchannels. Flow regimes investigated included laminar, transition and turbulent flow under forced convection and mixed convection conditions. Forced convections conditions were emphasized. Continuing efforts are underway at MIT to complete the investigation of the mixed convection regime initiated here. A number of investigations on outlet plenum behavior were also made. The reports of these investigations are identified

  17. Benefits and limitations of animal models in partial bladder outlet obstruction for translational research.

    Science.gov (United States)

    Kitta, Takeya; Kanno, Yukiko; Chiba, Hiroki; Higuchi, Madoka; Ouchi, Mifuka; Togo, Mio; Moriya, Kimihiko; Shinohara, Nobuo

    2018-01-01

    The functions of the lower urinary tract have been investigated for more than a century. Lower urinary tract symptoms, such as incomplete bladder emptying, weak urine stream, daytime urinary frequency, urgency, urge incontinence and nocturia after partial bladder outlet obstruction, is a frequent cause of benign prostatic hyperplasia in aging men. However, the pathophysiological mechanisms have not been fully elucidated. The use of animal models is absolutely imperative for understanding the pathophysiological processes involved in bladder dysfunction. Surgical induction has been used to study lower urinary tract functions of numerous animal species, such as pig, dog, rabbit, guinea pig, rat and mouse, of both sexes. Several morphological and functional modifications under partial bladder outlet obstruction have not only been observed in the bladder, but also in the central nervous system. Understanding the changes of the lower urinary tract functions induced by partial bladder outlet obstruction would also contribute to appropriate drug development for treating these pathophysiological conditions. In the present review, we discuss techniques for creating partial bladder outlet obstruction, the characteristics of several species, as well as issues of each model, and their translational value. © 2017 The Japanese Urological Association.

  18. A hydrologic regression sediment-yield model for two ungaged watershed outlet stations in Africa

    International Nuclear Information System (INIS)

    Moussa, O.M.; Smith, S.E.; Shrestha, R.L.

    1991-01-01

    A hydrologic regression sediment-yield model was established to determine the relationship between water discharge and suspended sediment discharge at the Blue Nile and the Atbara River outlet stations during the flood season. The model consisted of two main submodels: (1) a suspended sediment discharge model, which was used to determine suspended sediment discharge for each basin outlet; and (2) a sediment rating model, which related water discharge and suspended sediment discharge for each outlet station. Due to the absence of suspended sediment concentration measurements at or near the outlet stations, a minimum norm solution, which is based on the minimization of the unknowns rather than the residuals, was used to determine the suspended sediment discharges at the stations. In addition, the sediment rating submodel was regressed by using an observation equations procedure. Verification analyses on the model were carried out and the mean percentage errors were found to be +12.59 and -12.39, respectively, for the Blue Nile and Atbara. The hydrologic regression model was found to be most sensitive to the relative weight matrix, moderately sensitive to the mean water discharge ratio, and slightly sensitive to the concentration variation along the River Nile's course

  19. Epidemiology and pathogenesis of thoracic outlet syndrome

    Directory of Open Access Journals (Sweden)

    Wojcik Gustaw

    2015-03-01

    Full Text Available The superior thoracic aperture is a place particularly vulnerable to the occurrence of tissue conflict and the development of a number of neurovascular changes carrying a risk of upper limb dysfunction. The triggering factor in this case is the pressure on the nerve vascular elements brought about by too large muscles of the chest and neck, clavicle fracture and dislocation of the upper ribs, anomalies in the form of ribs, in the neck, or by apex of the lung tumors. Each anatomical anomaly may be a cause of a number of lesions and lead to the development of the disease. Due to the nature of the oppressed structures, there are two basic groups: neurogenic and vascular. The most common variant giving clinical symptoms is neurogenic thoracic outlet syndrome. In this, the compression ratio, the brachial plexus, and for this reason, the vascular surface of the upper limb dysfunction is often overlooked. However, the vascular variant, and especially arterial sub-variant, is very dangerous because it can give complications even in the form of aneurysms, and even upper limb ischemia. The aim of the study is to present the most common changes in the thoracic outlet causing functional disorders of the upper limb.

  20. Analysis of chiller units capacity for different heat loads considering variation of ambient air and cooling water temperature

    International Nuclear Information System (INIS)

    Coman, Aurelia Camelia; Tenescu, Mircea

    2010-01-01

    The paper purpose is to analyze the chiller units capacity to determine whether they can cope with high air and cooling water temperatures during summer time to remove heat loads imposed from Heating, Ventilation and Air Conditioning (HVAC) units in a CANDU 6 Nuclear Power Plant. The starting point is calculation of the overall heat transfer coefficient at the evaporator and condenser. They are used in heat balance equations of heat exchangers. A mathematical model was developed that simulates the refrigeration cycle to assess the response of chilled water system and its performance at different heat loads. In this analysis there were calculated values for inlet/outlet chilled water temperature and the refrigerant cycle thermodynamic parameters (condenser and evaporator pressure/temperature, refrigerant mass flowrate, refrigerant quality at the evaporator, refrigerant vapour superheated temperature at the compressor outlet, refrigerant subcooled temperature at the condenser outlet). To find the adequate functioning parameters of the installation, the MathCAD 13 software was used in all cases analyzed. The behaviour of the chiller units was investigated by examining the variation of three basic parameters, namely: - cooling water (river water) temperature; - air temperature; - heat load. The simultaneous variation of these three independent parameters allows to identify the actual chillers unit operating point (including chiller trip). (authors)

  1. Operativ behandling af thoracic outlet syndrome

    DEFF Research Database (Denmark)

    Birkeland, Peter; Stiasny, Jerzy

    2012-01-01

    of the brachial plexus. At surgery, we found and severed a fibrous band that compressed the inferior trunk. Postoperatively, the pain subsided and fine hand movements improved. One patient had no cervical rib, however, in the two other cases we found rudimentary cervical ribs. Magnetic resonance imaging......We present three cases with longstanding true neurogenic thoracic outlet syndrome. All patients had aching pain in the shoulder, arm and ulnar border of the hand. On examination, we found atrophy of the hand muscles. Electromyography revealed signs of compromised function of the inferior trunk...

  2. Access to food retail outlets in County Durham, UK: a pragmatic cross-sectional study.

    Science.gov (United States)

    Mills, Susanna; Wright, Tim

    2015-02-26

    Strong links exist between deprivation, obesity, and dietary quality. Increasing interest has focussed on the concept of access to food and so-called food deserts, defined by a policy working group of the UK Low Income Project Team in 1995 as "areas of relative exclusion where people experience physical and economic barriers to accessing healthy food". We aimed to establish the accessibility of food retail outlets in County Durham, a county in north-east England, UK, considering physical access, affordability, and food range and quality. In a pragmatic cross-sectional study in County Durham, we used information from town surveys and food business databases to locate and identify food retail outlets. The prevalence of deprivation, obesity, retail outlets, takeaway outlets, and ratio of retail to takeaway outlets was mapped, to establish local food access, and any associations with deprivation and obesity. The times taken to travel from residences to supermarkets using private car and public transport were also measured. 400 members of the community participated in eight focus groups and commissioned on-street surveys. Focus group transcripts were reviewed alongside the on-street survey responses to identify key issues. Most residents shopped at least weekly for food (n=368, 92%), used a supermarket for their main food shop (372, 93%), travelled for up to 15 min (340, 85%), and used a car for transport (188, 47%). Many survey respondents indicated high levels of satisfaction with food retail outlets (average rating 8·7 out of 10 for agreement with the statement "Overall I am satisfied with the shop where I do my main food shopping"), although financial constraints and transport inconvenience were identified as barriers. Difficulties with food shopping were more widely described in focus groups, and many individuals felt that local shopping provision had declined, with an emergent excess of takeaway outlets. Food retail access was reduced for the disabled, full

  3. Simulation of a proposed emergency outlet from Devils Lake, North Dakota

    Science.gov (United States)

    Vecchia, Aldo V.

    2002-01-01

    From 1993 to 2001, Devils Lake rose more than 25 feet, flooding farmland, roads, and structures around the lake and causing more than $400 million in damages in the Devils Lake Basin. In July 2001, the level of Devils Lake was at 1,448.0 feet above sea level1, which was the highest lake level in more than 160 years. The lake could continue to rise to several feet above its natural spill elevation to the Sheyenne River (1,459 feet above sea level) in future years, causing extensive additional flooding in the basin and, in the event of an uncontrolled natural spill, downstream in the Red River of the North Basin as well. The outlet simulation model described in this report was developed to determine the potential effects of various outlet alternatives on the future lake levels and water quality of Devils Lake.Lake levels of Devils Lake are controlled largely by precipitation on the lake surface, evaporation from the lake surface, and surface inflow. For this study, a monthly water-balance model was developed to compute the change in total volume of Devils Lake, and a regression model was used to estimate monthly water-balance data on the basis of limited recorded data. Estimated coefficients for the regression model indicated fitted precipitation on the lake surface was greater than measured precipitation in most months, fitted evaporation from the lake surface was less than estimated evaporation in most months, and ungaged inflow was about 2 percent of gaged inflow in most months. Dissolved sulfate was considered to be the key water-quality constituent for evaluating the effects of a proposed outlet on downstream water quality. Because large differences in sulfate concentrations existed among the various bays of Devils Lake, monthly water-balance data were used to develop detailed water and sulfate mass-balance models to compute changes in sulfate load for each of six major storage compartments in response to precipitation, evaporation, inflow, and outflow from

  4. Cosmogenic nuclides constrain surface fluctuations of an East Antarctic outlet glacier since the Pliocene.

    OpenAIRE

    Jones, R.S.; Norton, K.P.; Mackintosh, A.N.; Anderson, J.T.H.; Kubik, P.; Vockenhuber, C.; Wittman, H.; Fink, D.; Wilson, G.S.; Golledge, N.R.; McKay, R.

    2017-01-01

    Understanding past changes in the Antarctic ice sheets provides insight into how they might respond to future climate warming. During the Pliocene and Pleistocene, geological data show that the East Antarctic Ice Sheet responded to glacial and interglacial cycles by remaining relatively stable in its interior, but oscillating at its marine-based margin. It is currently not clear how outlet glaciers, which connect the ice sheet interior to its margin, responded to these orbitally-paced climate...

  5. Water temperature effects from simulated changes to dam operations and structures in the Middle and South Santiam Rivers, Oregon

    Science.gov (United States)

    Buccola, Norman L.

    2017-05-31

    Green Peter and Foster Dams on the Middle and South Santiam Rivers, Oregon, have altered the annual downstream water temperature profile (cycle). Operation of the dams has resulted in cooler summer releases and warmer autumn releases relative to pre-dam conditions, and that alteration can hinder recovery of various life stages of threatened spring-run Chinook salmon (Oncorhyncus tshawytscha) and winter steelhead (O. mykiss). Lake level management and the use of multiple outlets from varying depths at the dams can enable the maintenance of a temperature regime more closely resembling that in which the fish evolved by releasing warm surface water during summer and cooler, deeper water in the autumn. At Green Peter and Foster Dams, the outlet configuration is such that temperature control is often limited by hydropower production at the dams. Previously calibrated CE-QUAL-W2 water temperature models of Green Peter and Foster Lakes were used to simulate the downstream thermal effects from hypothetical structures and modified operations at the dams. Scenarios with no minimum power production requirements allowed some releases through shallower and deeper outlets (summer and autumn) to achieve better temperature control throughout the year and less year-to-year variability in autumn release temperatures. Scenarios including a hypothetical outlet floating 1 meter below the lake surface resulted in greater ability to release warm water during summer compared to existing structures. Later in Autumn (October 15–December 31), a limited amount of temperature control was realized downstream from Foster Dam by scenarios limited to operational changes with existing structures, resulting in 15-day averages within 1.0 degree Celsius of current operations.

  6. Operating temperatures for an LMFBR

    International Nuclear Information System (INIS)

    Bhoje, S.B.; Chellapandi, P.

    1993-01-01

    The scope of the present paper is limited to structural mechanics aspects that are associated with this technology. However, for the purpose of comprehensive presentation, all the other related issues are also highlighted. For this study, a Prototype Fast Breeder Reactor (PFBR) with 500 MWe capacity is taken as the reference design. Accordingly, some critical high temperature components of PFBR are analysed in- detail for elastic, inelastic and viscoplastic behaviour towards life prediction as per the requirement of design codes (RCC-MR 87) which form basis for justifying the possibility of higher operating temperatures for LMFBRs. Since operation with higher primary sodium outlet temperature in association with higher ΔT across the core is one of the efficient techniques towards making LMFBRs cost effective, operating Temperature limits are determined for a typical pool type FBR of 500 MWe capacity. Analysis indicates that control plug in the hot pool is the most critical component which limits the operating temperature to 820 K with a ΔT across the core of 160 K. By improving the thermal hydraulic design in conjunction with the structural design optimisation at the plate-shell junctions of control plug, possibility exists to go up to 840-850 K for primary outlet sodium with a T of 160 K across the core. This will result in producing steam of about 790-800 K (520 deg. C). Apart from improving the thermal hydraulic design to mitigate the transient thermal stresses, following are also needed to demonstrate higher safety margins in the design. Reduction of thermal transients, for an example, the temperature drop in the primary sodium outlet can be reduced by decreasing the sodium flow rate to the core, during a reactor scram. Welds should be avoided at the plate-shell junctions of control plug. A complete ring with necessary fillet radius may be forged as a single piece. In case of reactor vessel, a pullout option is better for redan-stand pipe junction

  7. Method for the determination of technical specifications limiting temperature in EBR-II operation

    International Nuclear Information System (INIS)

    Chang, L.K.; Hill, D.J.; Ku, J.Y.

    2004-01-01

    The methodology and analysis procedure to qualify the Mark-V and Mark-VA fuels for the Experimental Breeder Reactor II are summarized in this paper. Fuel performance data and design safety criteria are essential for thermal-hydraulic analyses and safety evaluations. Normal and off-normal operation duty cycles and transient classifications are required for the safety assessment of the fuels. Design safety criteria for steady-state normal and transient off-normal operations were developed to ensure structural integrity of the fuel pin. The maximum allowable coolant outlet temperatures and powers of subassemblies for steady-state normal operation conditions were first determined in a row-by-row basis by a thermal-hydraulic and fuel damage analysis, in which a trial-and-error approach was used to predict the maximum subassembly coolant outlet temperatures and powers that satisfy the design safety criteria for steady-state normal operation conditions. The limiting steady-state temperature and power were then used as the initial subassembly thermal conditions for the off-normal transient analysis to assess the safety performance of the fuel pin for anticipated, unlikely and extremely unlikely events. If the design safety criteria for the off-normal events are not satisfied, then the initial steady-state subassembly temperatures and/or powers are reduced and an iterative procedure is employed until the design safety criteria for off-normal conditions are satisfied, and the initial subassembly outlet coolant temperature and power are the technical specification limits for reactor operation. (author)

  8. OPERABILITY RATE OF DISTAL GASTRIC CANCER AND THE EFFECT OF GASTRIC OUTLET OBSTRUCTION IN THE OPERABILITY RATE AND POSTOPERATIVE OUTCOME- A RETROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Rajesh T. R

    2017-10-01

    Full Text Available BACKGROUND Stomach cancer is the fourth most common malignancy in the world. 1 Except in countries where screening for stomach cancer is prevalent, most of the distal stomach tumours are diagnosed at advanced stage. Gastric outlet obstruction is usually believed to be a sign of locally-advanced disease. Complete surgical removal of the disease (R0 is the only potentially curative treatment for resectable gastric cancer. The aim of the study is to finda The operability rate of gastric cancer in our institution and the incidence of Gastric Outlet Obstruction (GOO in patients undergoing gastrectomy for distal gastric cancer. b To compare the postoperative outcome in patients with gastric outlet obstruction and those without gastric outlet obstruction. c To see if the histology of the tumour has any role in the development of GOO. MATERIALS AND METHODS This is a retrospective study. The study includes patients who were admitted with carcinoma stomach and underwent operative or nonoperative treatment in our institution during 2013 to 2015. RESULTS Overall operability rate was 45.8%. Operable patients in the GOO group were 47%. Operability in the no outlet obstruction group were 45%. Data shows a slightly increased predilection for GOO in diffuse and mixed type of tumours (statistically not significant. Intestinal tumours had significant rate of anaemia compared to diffuse tumours (p <0.005. Overall mortality was 6.7%. Mortality is higher in the GOO group (8.8%. CONCLUSION (a. Operability rate of distal gastric cancer in our institution is 45.8%. (b. Incidence of gastric outlet obstruction in patients undergoing gastrectomy is 38.2%. (c. Presence of gastric outlet obstruction does not influence operability rate (47% vs. 45%. (d. Morbidity and mortality after distal radical gastrectomy is comparable in both groups. (e. Both intestinal and diffuse histology have equal incidence of GOO. (f. Chronic blood loss and incidence of anaemia is more in

  9. Antral hyperplastic polyp: A rare cause of gastric outlet obstruction.

    Science.gov (United States)

    Aydin, Ibrahim; Ozer, Ender; Rakici, Halil; Sehitoglu, Ibrahim; Yucel, Ahmet Fikret; Pergel, Ahmet; Sahin, Dursun Ali

    2014-01-01

    Gastric polyps are usually found incidentally during upper gastrointestinal endoscopic examinations. These polyps are generally benign, with hyperplasia being the most common. While gastric polyps are often asymptomatic, they can cause gastric outlet obstruction. A 64 years-old female patient presented to our polyclinic with a history of approximately 2 months of weakness, occasional early nausea, vomiting after meals and epigastric pain. A polypoid lesion of approximately 25mm in diameter was detected in the antral area of the stomach, which prolapsed through the pylorus into the duodenal bulbus, and subsequently caused gastric outlet obstruction, as revealed by upper gastrointestinal endoscopy of the patient. The polyp was retrieved from the pyloric canal into the stomach with the aid of a tripod, and snare polypectomy was performed. Currently, widespread use of endoscopy has led to an increase in the frequency of detecting hyperplastic polyps. While most gastric polyps are asymptomatic, they can cause iron deficiency anemia, acute pancreatitis and more commonly, gastric outlet obstruction because of their antral location. Although there are no precise principles in the treatment of asymptomatic polyps, polyps >5mm should be removed due to the possibility of malignant transformation. According to the medical evidence, polypectomy is required for gastric hyperplastic polyps because of the risks of complication and malignancy. These cases can be successfully treated endoscopically. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Study on Gas Field Optimization Distribution with Parameters Adjustment of the Air Duct Outlet for Mechanized Heading Face in Coal Mine

    Science.gov (United States)

    Gong, Xiao-Yan; Zhang, Xin-Yi; Wu, Yue; Xia, Zhi-Xin; Li, Ying

    2017-12-01

    At present, as the increasingly drilling dimensions with cross-section expansion and distance prolong in coal mine, the situation of gas accumulation in mechanized heading face becomes severe. In this paper, optimization research of gas distribution was carried out by adjusting parameters of the air duct outlet, including angle, caliber and the front and rear distance of air duct outlet. Mechanized heading face of Ningtiaota coal mine was taken as the research object, simulated and analyzed the problems of original gas field, the reasonable parameters range of the air duct outlet was determined according to the allowable range of wind speed and the effect of gas dilution, the adjustment range of each parameter of the air duct outlet is preliminarily determined. Base on this, the distribution of gas field under different parameters adjustment of air duct outlet was simulated. The specific parameters under the different distance between the air duct outlet and the mechanized heading face were obtained, and a new method of optimizing the gas distribution by adjusting parameters of the air duct outlet was provided.

  11. 46 CFR 111.81-1 - Outlet boxes and junction boxes; general.

    Science.gov (United States)

    2010-10-01

    ... fixture, wiring device, or similar item, including each separately installed connection and junction box... used. (d) As appropriate, each outlet-box or junction-box installation must meet the following...

  12. Gas pressure in bubble attached to tube circular outlet

    OpenAIRE

    Salonen, A; Gay, Cyprien; Maestro, A; Drenckhan, W; Rio, Emmanuelle

    2016-01-01

    In the present Supplementary notes to our work ``Arresting bubble coarsening: A two-bubble experiment to investigate grain growth in presence of surface elasticity'' (accepted in EPL), we derive the expression of the gas pressure inside a bubble located above and attached to the circular outlet of a vertical tube.

  13. Utilization of Cupping Therapy in the Treatment of Vascular Thoracic Outlet Syndrome in a Collegiate Pitcher: A Case Study

    Directory of Open Access Journals (Sweden)

    Stephen A. Cage

    2017-12-01

    Full Text Available Objective: Present a clinical case detailing the effectiveness of dry cupping therapy in treating thoracic outlet syndrome. The utilization of dry cupping therapy on a 20-year-old collegiate baseball pitcher with diagnosed thoracic outlet syndrome is presented. Background: Thoracic outlet syndrome is a relatively rare musculoskeletal condition affecting 1/100,000 patients annually. Dry cupping therapy is an ancient therapeutic modality that utilizes various means of suction with the goal of decompressing myofascial layers. Treatment: Following diagnosis, patient was successfully treated in two weeks using dry cupping therapy. The patient experienced no further incidence of thoracic outlet syndrome symptoms and was able to complete the remainder of his competitive season. Uniqueness: The patient’s thoracic outlet syndrome was diagnosed at an early stage, leading to the need of clearance from a vascular specialist before returning to competition. To the author’s knowledge, there are currently no published case reports detailing the use of cupping therapy to treat thoracic outlet syndrome. Conclusion: Cupping therapy may be a viable treatment option when seeking to address tight musculature. Further research needs to be conducted to determine optimal parameters for cupping therapy as a therapeutic modality.

  14. 5 CFR 591.217 - In which outlets does OPM collect prices?

    Science.gov (United States)

    2010-01-01

    ... data collection areas, accessibility by road, physical size, advertising, and other characteristics that reflect sales volume. To the extent practical, OPM prices like items in the same types of outlets...

  15. The Integration Of Process Heat Applications To High Temperature Gas Reactors

    International Nuclear Information System (INIS)

    McKellar, Michael G.

    2011-01-01

    A high temperature gas reactor, HTGR, can produce industrial process steam, high-temperature heat-transfer gases, and/or electricity. In conventional industrial processes, these products are generated by the combustion of fossil fuels such as coal and natural gas, resulting in significant emissions of greenhouse gases such as carbon dioxide. Heat or electricity produced in an HTGR could be used to supply process heat or electricity to conventional processes without generating any greenhouse gases. Process heat from a reactor needs to be transported by a gas to the industrial process. Two such gases were considered in this study: helium and steam. For this analysis, it was assumed that steam was delivered at 17 MPa and 540 C and helium was delivered at 7 MPa and at a variety of temperatures. The temperature of the gas returning from the industrial process and going to the HTGR must be within certain temperature ranges to maintain the correct reactor inlet temperature for a particular reactor outlet temperature. The returning gas may be below the reactor inlet temperature, ROT, but not above. The optimal return temperature produces the maximum process heat gas flow rate. For steam, the delivered pressure sets an optimal reactor outlet temperature based on the condensation temperature of the steam. ROTs greater than 769.7 C produce no additional advantage for the production of steam.

  16. Calculation of plate temperatures in a Mk 4 LEU fuel element

    International Nuclear Information System (INIS)

    Haack, K.

    1988-09-01

    A calculation method for estimating the axial temperature distributions of each tube in each of the 26 fuel elements of the DR 3 core is described and demonstrated. With input data for fuel element power, D2O outlet temperature and main D2O circulator combination, a computer code calculates all important temperatures in the fuel element. 11 tabs., 32 ills. 8 refs. (author)

  17. Publication Outlets for School Psychology Faculty: 2010 to 2015

    Science.gov (United States)

    Hulac, David; Johnson, Natalie D.; Ushijima, Shiho C.; Schneider, Maryia M.

    2016-01-01

    Many school psychology faculty are required to publish for purposes of retention and promotion. It is useful to have an understanding of the different outlets for scholarly publications. In the present study, we investigated the peer-reviewed journals in which school psychology faculty were published between 2010 and 2015, the number of articles…

  18. Outlet strut fracture of Björk-Shiley convexo-concave valves: can valve-manufacturing characteristics explain the risk?

    Science.gov (United States)

    Omar, R Z; Morton, L S; Beirne, M; Blot, W J; Lawford, P V; Hose, R; Taylor, K M

    2001-06-01

    Björk-Shiley 60 degrees convexo-concave prosthetic heart valves (Shiley, Inc, Irvine, Calif, a subsidiary of Pfizer, Inc) continue to be a concern for approximately 35,000 nonexplanted patients worldwide, with approximately 600 events reported to the manufacturer to date. Fractures of the outlet struts of the valves began to appear in the early 1980s and have continued to the present, but their causes are only partially understood. A matched case-control study was conducted evaluating manufacturing records for 52 valves with outlet strut fractures and 248 control subjects matched for age at implantation, valve size, and valve position. In addition to the risk factors recognized as determinants of outlet strut fracture, the United Kingdom case-control study has observed 7- to 9-fold increased risk with performance of multiple hook deflection tests. This test was performed more than once, usually after rework on the valve. Six valves in this study underwent multiple hook deflection tests, of which 4 experienced an outlet strut fracture. Cracks and further rework were noted for these valves. Significant associations were also observed between outlet strut fracture and disc-to-strut gap measurements taken before the attachment of the sewing ring. It is our view that a combination of factors related to valve design, manufacturing process, and patient characteristics are responsible for outlet strut fractures of Björk-Shiley convexo-concave valves. Multiple hook deflection tests have emerged as a potential new risk factor for outlet strut fracture in both The Netherlands and the United Kingdom. This factor appears to be correlated with the presence of other abnormalities. A further study is needed to investigate the factors correlated with multiple hook deflection tests. On confirmation of risk, the presence of multiple hook deflection tests may be added to equations, quantifying the risk of outlet strut fracture for comparison against risk of mortality and serious

  19. Bilateral Upper Extremity DVT in a 43-Year-Old Man: Is It Thoracic Outlet Syndrome?!

    Directory of Open Access Journals (Sweden)

    Hadoun Jabri

    2014-01-01

    Full Text Available Recurrent deep venous thrombosis, involving bilateral upper extremities, is an extremely rare phenomenon. We are presenting a 43-year-old man who was diagnosed with left upper extremity deep vein thrombosis (UEDVT and was treated with anticoagulation and surgical decompression in 2004. 9 years later, he presented with right arm swelling and was diagnosed with right UEDVT using US venous Doppler. Venogram showed compression of the subclavian vein by the first rib, diagnosing thoracic outlet syndrome (TOS. He was treated with anticoagulation and local venolysis and later by surgical decompression of the subclavian vein. Bilateral UEDVT, as mentioned above, is an extremely rare condition that is uncommonly caused by TOS. To our knowledge, we are reporting the first case of bilateral UEDVT due to TOS. Diagnosis usually starts with US venous Doppler to detect the thrombosis, followed by the gold standard venogram to locate the area of obstruction and lyse the thrombus if needed. The ultimate treatment for TOS remains surgical decompression of the vascular bundle at the thoracic outlet.

  20. Water temperature effects from simulated dam operations and structures in the Middle Fork Willamette River, western Oregon

    Science.gov (United States)

    Buccola, Norman L.; Turner, Daniel F.; Rounds, Stewart A.

    2016-09-14

    Significant FindingsStreamflow and water temperature in the Middle Fork Willamette River (MFWR), western Oregon, have been regulated and altered since the construction of Lookout Point, Dexter, and Hills Creek Dams in 1954 and 1961, respectively. Each year, summer releases from the dams typically are cooler than pre-dam conditions, with the reverse (warmer than pre-dam conditions) occurring in autumn. This pattern has been detrimental to habitat of endangered Upper Willamette River (UWR) Chinook salmon (Oncorhynchus tshawytscha) and UWR winter steelhead (O. mykiss) throughout multiple life stages. In this study, scenarios testing different dam-operation strategies and hypothetical dam-outlet structures were simulated using CE-QUAL-W2 hydrodynamic/temperature models of the MFWR system from Hills Creek Lake (HCR) to Lookout Point (LOP) and Dexter (DEX) Lakes to explore and understand the efficacy of potential flow and temperature mitigation options.Model scenarios were run in constructed wet, normal, and dry hydrologic calendar years, and designed to minimize the effects of Hills Creek and Lookout Point Dams on river temperature by prioritizing warmer lake surface releases in May–August and cooler, deep releases in September–December. Operational scenarios consisted of a range of modified release rate rules, relaxation of power-generation constraints, variations in the timing of refill and drawdown, and maintenance of different summer maximum lake levels at HCR and LOP. Structural scenarios included various combinations of hypothetical floating outlets near the lake surface and hypothetical new outlets at depth. Scenario results were compared to scenarios using existing operational rules that give temperature management some priority (Base), scenarios using pre-2012 operational rules that prioritized power generation over temperature management (NoBlend), and estimated temperatures from a without-dams condition (WoDams).Results of the tested model scenarios led

  1. Using marine sediment archives to reconstruct past outlet glacier variability

    DEFF Research Database (Denmark)

    Andresen, Camilla Snowman; Straneo, Fiamma; Ribergaard, Mads

    2013-01-01

    Ice-rafted debris in fjord sediment cores provides information about outlet glacier activity beyond the instrumental time period. It tells us that the Helheim Glacier, Greenland’s third most productive glacier, responds rapidly to short-term (3 to 10 years) climate changes....

  2. Alcohol outlet densities and alcohol price: the British Columbia experiment in the partial privatization of alcohol sales off-premise.

    Science.gov (United States)

    Treno, Andrew J; Ponicki, William R; Stockwell, Tim; Macdonald, Scott; Gruenewald, Paul J; Zhao, Jinhui; Martin, Gina; Greer, Alissa

    2013-05-01

    Alcohol beverage prices or taxes have been shown to be related to alcohol sales and use and related problems. What is not clear are the mechanisms underlying these relationships. This study examines the relationship between alcohol outlet density under conditions of the partial privatization of off-premise consumption in British Columbia (BC) occurring over the past decade. Two hypotheses are tested. First, reflecting basic supply-demand principles, greater geographic densities of alcohol outlets will be directly related to reductions in beverage prices in response to greater competition. Second, reflecting the effects of niche marketing and resulting market stratification, increased densities of private liquor stores will be especially related to reductions in beverage prices within this outlet category. Data were collected from: (i) a survey of BC private store prices and practices, (ii) alcohol outlet location information, and (iii) data on demographic characteristics. Multilevel models examine the relationships between prices at individual private liquor stores and the densities of government liquor stores, private liquor stores, bars, and restaurants, controlling for background demographics and geographic unit level effects. Spatial dependencies were also examined. Increased densities of private liquor stores were associated with lower mean prices of beer and all alcohol aggregated across brands at the store level. There appeared to be no outlet level effect on discounting patterns, however, with the mean price differences apparently reflecting differences in the quality of brands carried rather than unequal prices for any given brand. Increased densities of private off-sale alcohol outlets appear to result in lower prices charged at said establishments independently of other types of alcohol outlets suggesting that they represent an emerging marketing niche in the context of off-sale outlet privatization. Copyright © 2012 by the Research Society on

  3. Predictive factors of bladder outlet obstruction following the tension ...

    African Journals Online (AJOL)

    H. Elghamrawi

    On the other hand, multivariate analysis indicated that Qmax was the only factor independently related to postoperative bladder outlet obstruction after TVTO (p = 0.002, odds ratio = 0.658, 95% CI for odds ratio 0.507–0.855). Discussion. Stress urinary incontinence defined as the involuntary loss of urine during increases in ...

  4. Map-based prediction of organic carbon in headwater streams improved by downstream observations from the river outlet

    Science.gov (United States)

    Temnerud, J.; von Brömssen, C.; Fölster, J.; Buffam, I.; Andersson, J.-O.; Nyberg, L.; Bishop, K.

    2016-01-01

    In spite of the great abundance and ecological importance of headwater streams, managers are usually limited by a lack of information about water chemistry in these headwaters. In this study we test whether river outlet chemistry can be used as an additional source of information to improve the prediction of the chemistry of upstream headwaters (size interquartile range (IQR)) of headwater stream TOC for a given catchment, based on a large number of candidate variables including sub-catchment characteristics from GIS, and measured river chemistry at the catchment outlet. The best candidate variables from the PLS models were then used in hierarchical linear mixed models (MM) to model TOC in individual headwater streams. Three predictor variables were consistently selected for the MM calibration sets: (1) proportion of forested wetlands in the sub-catchment (positively correlated with headwater stream TOC), (2) proportion of lake surface cover in the sub-catchment (negatively correlated with headwater stream TOC), and (3) river outlet TOC (positively correlated with headwater stream TOC). Including river outlet TOC improved predictions, with 5-15 % lower prediction errors than when using map information alone. Thus, data on water chemistry measured at river outlets offer information which can complement GIS-based modelling of headwater stream chemistry.

  5. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-01-01

    Abstract Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group. PMID:26200641

  6. Survey of Publication Outlets in Early Childhood Education: Descriptive Data, Review Processes, and Advice to Authors

    Science.gov (United States)

    Amodei, Michelle L.; Jalongo, Mary Renck; Myers, Jacqueline; Onchwari, Jacqueline; Gargiulo, Richard M.

    2013-01-01

    Publishing outlets in the field of early childhood vary widely in terms of emphasis on theory, practice, and research as they relate to the care and education of the very young; these outlets also have different readerships (i.e., primarily for teachers, the teachers of their teachers, or the fellow scholars/researchers). Included in the mixture…

  7. Thermal performance of an open thermosyphon using nanofluid for evacuated tubular high temperature air solar collector

    International Nuclear Information System (INIS)

    Liu, Zhen-Hua; Hu, Ren-Lin; Lu, Lin; Zhao, Feng; Xiao, Hong-shen

    2013-01-01

    Highlights: • A novel solar air collector with simplified CPC and open thermosyphon is designed and tested. • Simplified CPC has a much lower cost at the expense of slight efficiency loss. • Nanofluid effectively improves thermal performance of the above solar air collector. • Solar air collector with open thermosyphon is better than that with concentric tube. - Abstract: A novel evacuated tubular solar air collector integrated with simplified CPC (compound parabolic concentrator) and special open thermosyphon using water based CuO nanofluid as the working fluid is designed to provide air with high and moderate temperature. The experimental system has two linked panels and each panel includes an evacuated tube, a simplified CPC and an open thermosyphon. Outdoor experimental study has been carried out to investigate the actual solar collecting performance of the designed system. Experimental results show that air outlet temperature and system collecting efficiency of the solar air collector using nanofluid as the open thermosyphon’s working fluid are both higher than that using water. Its maximum air outlet temperature exceeds 170 °C at the air volume rate of 7.6 m 3 /h in winter, even though the experimental system consists of only two collecting panels. The solar collecting performance of the solar collector integrated with open thermosyphon is also compared with that integrated with common concentric tube. Experimental results show that the solar collector integrated with open thermosyphon has a much better collecting performance

  8. Temperature measurement device

    International Nuclear Information System (INIS)

    Fournier, Christian; Lions, Noel.

    1975-01-01

    The present invention relates to a temperature measuring system that can be applied in particular to monitoring the temperature of the cooling liquid metal of the outlet of the core assemblies of a fast reactor. Said device combines a long hollow metallic pole, at least partially dipped into the liquid metal and constituting a first thermocouple junction between said pole, and two metallic conductors of different nature, joined at one of their ends to constitute the second thermocouple junction. Said conductors suitably insulated are arranged inside a sheath. Said sheath made of the same metals as the pole extends inside the latter and is connected with the pole through a soldered joint. Said reliable system permits an instantaneous measurement of a quantity representing the variations in the recorded temperature and a measurement of the mean surrounding temperature that can be direcly used as a reference for calibrating the first one [fr

  9. Numerical Investigation on the Influence of Hot Streak Temperature Ratio in a High-Pressure Stage of Vaneless Counter-Rotating Turbine

    Directory of Open Access Journals (Sweden)

    Zhao Qingjun

    2007-01-01

    Full Text Available The results of recent studies have shown that combustor exit temperature distortion can cause excessive heat load of high-pressure turbine (HPT rotor blades. The heating of HPT rotor blades can lead to thermal fatigue and degrade turbine performance. In order to explore the influence of hot streak temperature ratio on the temperature distributions of HPT airfoil surface, three-dimensional multiblade row unsteady Navier-Stokes simulations have been performed in a vaneless counter-rotating turbine (VCRT. The hot streak temperature ratios from 1.0 (without hot streak to 2.4 were used in these numerical simulations, including 1.0, 1.2, 1.6, 2.0, and 2.4 temperature ratios. The hot streak is circular in shape with a diameter equal to 25% of the span. The center of the hot streak is located at 50% of span and 0% of pitch (the leading edge of the HPT stator vane. The predicted results show that the hot streak is relatively unaffected as it migrates through the HPT stator. The hot streak mixes with the vane wake and convects towards the pressure surface (PS of the HPT rotor when it moves over the vane surface of the HPT stator. The heat load of the HPT rotor increases with the increase of the hot streak temperature ratio. The existence of the inlet temperature distortion induces a thin layer of cooler air in the HPT rotor, which separates the PS of the HPT rotor from the hotter fluid. The numerical results also indicating the migration characteristics of the hot streak in the HPT rotor are predominated by the combined effects of secondary flow and buoyancy. The combined effects that induce the high-temperature fluid migrate towards the hub on the HPT rotor. The effect of the secondary flow on the hotter fluid increases as the hot streak temperature ratio is increased. The influence of buoyancy is directly proportional to the hot streak temperature ratio. The predicted results show that the increase of the hot streak temperature ratio trends to increase

  10. The effect of fan speed control system on the inlet air temperature uniformity in a solar dryer

    Directory of Open Access Journals (Sweden)

    S. F Mousavi

    2015-09-01

    temperature was 38 and 37.8C, respectively. The results showed that with fan speed control mode the variation of inlet air temperature of the drying chamber was more limited and remained within the range of 39 to 42 and 40 to 42°C during the two experimental days, respectively. However, without fan speed control, the system exhibited a wider variation of inlet drying air temperature and limited within the range of 33 to 44 and 32 to 43°C. Furthermore, with fan speed control in a solar dryer, along with more uniformity in moisture content, the drying rate may speed up and with further decrease in final moisture content up to 8%, when compared to a system with no fan speed control. Conclusions: The average temperatures of the outlet air of collector in two days with fan speed control system, were 40.6 and 40.8°C while in the system without the fan speed control, were 38 and 37.8, respectively. This clearly indicates that the system control could increase the temperature of the collector outlet. The dryer was also able to control the fan speed during the 9hours of drying mint with initial moisture content of 85% (w.b and to reduce it to about 24.5 and 25.5%, during the two experimental days, respectively. While the corresponding values without the use of a control system were 33.5 and 33.5%, respectively. In other words, in the experiments with the use of control system, the final moisture content was about 8% lower than the moisture content of materials dried without such a system. Furthermore, the control system reduces the volume of air required by the system and hence speeds up the drying process.

  11. A cross sectional study investigating the association between exposure to food outlets and childhood obesity in Leeds, UK.

    Science.gov (United States)

    Griffiths, Claire; Frearson, Anna; Taylor, Adam; Radley, Duncan; Cooke, Carlton

    2014-12-06

    Current UK policy in relation to the influence of the 'food environment' on childhood obesity appears to be driven largely on assumptions or speculations because empirical evidence is lacking and findings from studies are inconsistent. The aim of this study was to investigate the number of food outlets and the proximity of food outlets in the same sample of children, without solely focusing on fast food. Cross sectional study over 3 years (n = 13,291 data aggregated). Body mass index (BMI) was calculated for each participant, overweight and obesity were defined as having a BMI >85(th) (sBMI 1.04) and 95(th) (sBMI 1.64) percentiles respectively (UK90 growth charts). Home and school neighbourhoods were defined as circular buffers with a 2 km Euclidean radius, centred on these locations. Commuting routes were calculated using the shortest straight line distance, with a 2 km buffer to capture varying routes. Data on food outlet locations was sourced from Leeds City Council covering the study area and mapped against postcode. Food outlets were categorised into three groups, supermarkets, takeaway and retail. Proximity to the nearest food outlet in the home and school environmental domain was also investigated. Age, gender, ethnicity and deprivation (IDACI) were included as covariates in all models. There is no evidence of an association between the number of food outlets and childhood obesity in any of these environments; Home Q4 vs. Q1 OR = 1.11 (95% CI = 0.95-1.30); School Q4 vs. Q1 OR = 1.00 (95% CI 0.87 - 1.16); commute Q4 vs. Q1 OR = 0.1.00 (95% CI 0.83 - 1.20). Similarly there is no evidence of an association between the proximity to the nearest food outlet and childhood obesity in the home (OR = 0.77 [95% CI = 0.61 - 0.98]) or the school (OR = 1.01 [95% CI 0.84 - 1.23]) environment. This study provides little support for the notion that exposure to food outlets in the home, school and commuting neighbourhoods increase the risk of obesity

  12. Control rod position and temperature coefficients in HTTR power-rise tests. Interim report

    International Nuclear Information System (INIS)

    Fujimoto, Nozomu; Nojiri, Naoki; Takada, Eiji; Saito, Kenji; Kobayashi, Shoichi; Sawahata, Hiroaki; Kokusen, Sigeru

    2001-03-01

    Power-rise tests of the High Temperature Engineering Test Reactor (HTTR) have been carried out aiming to achieve 100% power. So far, 50% of power operation and many tests have been carried out. In the HTTR, temperature change in core is so large to achieve the outlet coolant temperature of 950degC. To improve the calculation accuracy of the HTTR reactor physics characteristics, control rod positions at criticality and temperature coefficients were measured at each step to achieve 50% power level. The calculations were carried out using Monte Carlo code and diffusion theory with temperature distributions in the core obtained by reciprocal calculation of thermo-hydraulic code and diffusion theory. Control rod positions and temperature coefficients were calculated by diffusion theory and Monte Carlo method. The test results were compared to calculation results. The control rod positions at criticality showed good agreement with calculation results by Monte Carlo method with error of 50 mm. The control position at criticality at 100% was predicted around 2900mm. Temperature coefficients showed good agreement with calculation results by diffusion theory. The improvement of calculation will be carried out comparing the measured results up to 100% power level. (author)

  13. Control of the outlet air temperature in an air handling unit

    DEFF Research Database (Denmark)

    Brath, P.; Rasmussen, Henrik; Hägglund, T.

    1998-01-01

    This paper discuss modeling and control of the inlet temperature in an Air Handling Unit, AHU. The model is based on step response experiments made at a full scale test plant. We use gain scheduling to lower the correlation of the air flow with the process dynamic which simplify the control task...

  14. Procedure for prolapse and hemorrhoids vs traditional surgery for outlet obstructive constipation.

    Science.gov (United States)

    Lu, Ming; Yang, Bo; Liu, Yang; Liu, Qing; Wen, Hao

    2015-07-14

    To compare the clinical efficacies of two surgical procedures for hemorrhoid rectal prolapse with outlet obstruction-induced constipation. One hundred eight inpatients who underwent surgery for outlet obstructive constipation caused by internal rectal prolapse and circumferential hemorrhoids at the First Affiliated Hospital of Xinjiang Medical University from June 2012 to June 2013 were prospectively included in the study. The patients with rectal prolapse hemorrhoids with outlet obstruction-induced constipation were randomly divided into two groups to undergo either a procedure for prolapse and hemorrhoids (PPH) (n = 54) or conventional surgery (n = 54; control group). Short-term (operative time, postoperative hospital stay, postoperative urinary retention, postoperative perianal edema, and postoperative pain) and long-term (postoperative anal stenosis, postoperative sensory anal incontinence, postoperative recurrence, and postoperative difficulty in defecation) clinical effects were compared between the two groups. The short- and long-term efficacies of the two procedures were determined. In terms of short-term clinical effects, operative time and postoperative hospital stay were significantly shorter in the PPH group than in the control group (24.36 ± 5.16 min vs 44.27 ± 6.57 min, 2.1 ± 1.4 d vs 3.6 ± 2.3 d, both P hemorrhoids.

  15. Transient Air-Water Flow and Air Demand following an Opening Outlet Gate

    Directory of Open Access Journals (Sweden)

    James Yang

    2018-01-01

    Full Text Available In Sweden, the dam-safety guidelines call for an overhaul of many existing bottom outlets. During the opening of an outlet gate, understanding the transient air-water flow is essential for its safe operation, especially under submerged tailwater conditions. Three-dimensional CFD simulations are undertaken to examine air-water flow behaviors at both free and submerged outflows. The gate, hoisted by wire ropes and powered by AC, opens at a constant speed. A mesh is adapted to follow the gate movement. At the free outflow, the CFD simulations and model tests agree well in terms of outlet discharge capacity. Larger air vents lead to more air supply; the increment becomes, however, limited if the vent area is larger than 10 m2. At the submerged outflow, a hydraulic jump builds up in the conduit when the gate reaches approximately 45% of its full opening. The discharge is affected by the tailwater and slightly by the flow with the hydraulic jump. The flow features strong turbulent mixing of air and water, with build-up and break-up of air pockets and collisions of defragmented water bodies. The air demand rate is several times as much as required by steady-state hydraulic jump with free surface.

  16. Turbofan gas turbine engine with variable fan outlet guide vanes

    Science.gov (United States)

    Wood, Peter John (Inventor); LaChapelle, Donald George (Inventor); Grant, Carl (Inventor); Zenon, Ruby Lasandra (Inventor); Mielke, Mark Joseph (Inventor)

    2010-01-01

    A turbofan gas turbine engine includes a forward fan section with a row of fan rotor blades, a core engine, and a fan bypass duct downstream of the forward fan section and radially outwardly of the core engine. The forward fan section has only a single stage of variable fan guide vanes which are variable fan outlet guide vanes downstream of the forward fan rotor blades. An exemplary embodiment of the engine includes an afterburner downstream of the fan bypass duct between the core engine and an exhaust nozzle. The variable fan outlet guide vanes are operable to pivot from a nominal OGV position at take-off to an open OGV position at a high flight Mach Number which may be in a range of between about 2.5-4+. Struts extend radially across a radially inwardly curved portion of a flowpath of the engine between the forward fan section and the core engine.

  17. CFD analyses of the rod bowing effect on the subchannel outlet temperature distribution

    Energy Technology Data Exchange (ETDEWEB)

    Ekstroem, Karoliina; Toppila, Timo [Fortum Power and Heat, Fortum (Finland)

    2017-09-15

    In the Loviisa 1 and 2 nuclear power plants the subcooling margin of the hottest subchannel of the fuel assembly is monitored. The temperature of the coolant in the hottest subchannel is limited to the constant saturation temperature. Bending of the fuel rods occurs during normal operation due to the differences in the heat profiles of the rods. The coolant temperature will rise more in the subchannel with smaller flow area due to the bending and this has to be taken into account in the safety margin of subchannel enthalpy rise. Computational Fluid Dynamics (CFD) simulations are used to estimate how much the estimated maximum bow of a rod affects the temperature rise of the subchannel. The quantitative uncertainty of the predicted enthalpy rise in fuel bundle subchannel is estimated based on the uncertainty of modelling of mixing between subchannels. The measured turbulence quantities from LDA measurements of cold test assembly made in 1990s in Fortum are compared with CFD results to give uncertainty estimation for turbulence, which is further used for uncertainty estimation of mixing and simulated subchannel enthalpy rise.

  18. Study on the natural air cooling design of electronic equipment casings: Effects of the height and size of outlet vent on the flow resistances

    International Nuclear Information System (INIS)

    Ishizuka, M; Hatakeyama, T; Kibushi, R; Inoue, M

    2012-01-01

    This paper describes the effects of the outlet vent size and the distance between the outlet vent location and the power heater position on the flow resistance in natural-air-cooled electronic equipment casings. An experiment was carried out using a simple model casing simulated for the practical natural-air-cooled casing which is composed of 4 side walls, a top plate and bottom plate which has an inlet opening. A power heater to served as a power dissipation unit was placed at its open bottom. An outlet opening was set on one of the side walls. The opening area, the height of the outlet and the heater location were varied. The experimental results were analyzed using the flow resistance coefficient K which was related to the distance between the outlet vent and the power heater position and the heat removal from the outlet vent, and K values were plotted against a pair of Reynolds numbers Re and the outlet vent porosity β which is defined as the ratio of outlet vent open area to the top surface area of the casing.

  19. Effect of inlet and outlet flow conditions on natural gas parameters in supersonic separation process.

    Directory of Open Access Journals (Sweden)

    Yan Yang

    Full Text Available A supersonic separator has been introduced to remove water vapour from natural gas. The mechanisms of the upstream and downstream influences are not well understood for various flow conditions from the wellhead and the back pipelines. We used a computational model to investigate the effect of the inlet and outlet flow conditions on the supersonic separation process. We found that the shock wave was sensitive to the inlet or back pressure compared to the inlet temperature. The shock position shifted forward with a higher inlet or back pressure. It indicated that an increasing inlet pressure declined the pressure recovery capacity. Furthermore, the shock wave moved out of the diffuser when the ratio of the back pressure to the inlet one was greater than 0.75, in which the state of the low pressure and temperature was destroyed, resulting in the re-evaporation of the condensed liquids. Natural gas would be the subsonic flows in the whole supersonic separator, if the mass flow rate was less than the design value, and it could not reach the low pressure and temperature for the condensation and separation of the water vapor. These results suggested a guidance mechanism for natural gas supersonic separation in various flow conditions.

  20. Healthier choices in an Australian health service: a pre-post audit of an intervention to improve the nutritional value of foods and drinks in vending machines and food outlets.

    Science.gov (United States)

    Bell, Colin; Pond, Nicole; Davies, Lynda; Francis, Jeryl Lynn; Campbell, Elizabeth; Wiggers, John

    2013-11-25

    Vending machines and shops located within health care facilities are a source of food and drinks for staff, visitors and outpatients and they have the potential to promote healthy food and drink choices. This paper describes perceptions of parents and managers of health-service located food outlets towards the availability and labelling of healthier food options and the food and drinks offered for sale in health care facilities in Australia. It also describes the impact of an intervention to improve availability and labelling of healthier foods and drinks for sale. Parents (n = 168) and food outlet managers (n = 17) were surveyed. Food and drinks for sale in health-service operated food outlets (n = 5) and vending machines (n = 90) in health care facilities in the Hunter New England region of NSW were audited pre (2007) and post (2010/11) the introduction of policy and associated support to increase the availability of healthier choices. A traffic light system was used to classify foods from least (red) to most healthy choices (green). Almost all (95%) parents and most (65%) food outlet managers thought food outlets on health service sites should have signs clearly showing healthy choices. Parents (90%) also thought all food outlets on health service sites should provide mostly healthy items compared to 47% of managers. The proportion of healthier beverage slots in vending machines increased from 29% to 51% at follow-up and the proportion of machines that labelled healthier drinks increased from 0 to 26%. No outlets labelled healthier items at baseline compared to 4 out of 5 after the intervention. No changes were observed in the availability or labelling of healthier food in vending machines or the availability of healthier food or drinks in food outlets. Baseline availability and labelling of healthier food and beverage choices for sale in health care facilities was poor in spite of the support of parents and outlet managers for such initiatives. The intervention

  1. Report of an adult with double-outlet right ventricle

    International Nuclear Information System (INIS)

    Munera E, Ana G; Florez C, Marina; Delgado de B, Jorge A and others

    2001-01-01

    The case of a 22 -year- old woman with a diagnosis of congenital heart disease, N Y H A class I, who complaints palpitations. By echocardiography, angiography and magnetic resonance imaging a diagnosis of double-outlet right ventricle was done. She was intervened for correction, creating an interventricular tunnel connecting the left ventricle to the aorta through the ventricular septal defect

  2. [Retail food outlets and the association with overweight/obesity in schoolchildren from Florianópolis, Santa Catarina State, Brazil].

    Science.gov (United States)

    Motter, Adriana Filimberti; Vasconcelos, Francisco de Assis Guedes de; Correa, Elizabeth Nappi; Andrade, Dalton Francisco de

    2015-03-01

    The study analyzes retail food outlets and their association with overweight/obesity in schoolchildren from Florianópolis, Santa Catarina State, Brazil. The study used a cross-sectional design with a random sample of 2,506 schoolchildren from public (n = 19) and private schools (n = 11). Overweight and obesity were classified according to World Health Organization guidelines for 2007, and crude and adjusted analyses were performed using Poisson regression. Prevalence of overweight/obesity was 34.2%. In public schools, 19.6% of the children were overweight and 13.5% were obese, as compared to 22.4% and 11.1% in private schools. An association was found in the public school system between overweight/obesity and the use of bakeries for food purchases (p = 0.004). In the private school system, children of families that bought groceries at the supermarket showed 26% less overweight/obesity compared to those who did not (p = 0.003). The data show an association between some types of food outlets (supermarkets and bakeries) and prevalence of overweight/obesity in the school-age population.

  3. Vendor-to-vendor education to improve malaria treatment by private drug outlets in Bungoma District, Kenya

    Directory of Open Access Journals (Sweden)

    Makama Sammy

    2003-05-01

    Full Text Available Abstract Background Private outlets are the main suppliers of uncomplicated malaria treatment in Africa. However, they are so numerous that they are difficult for governments to influence and regulate. This study's objective was to evaluate a low-cost outreach education (vendor-to-vendor programme to improve the private sector's compliance with malaria guidelines in Bungoma district, Kenya. The cornerstone of the programme was the district's training of 73 wholesalers who were equipped with customized job aids for distribution to small retailers. Methods Six months after training the wholesalers, the programme was evaluated using mystery shoppers. The shoppers posed as caretakers of sick children needing medication at 252 drug outlets. Afterwards, supervisors assessed the outlets' knowledge, drug stocks, and prices. Results The intervention seems to have had a significant impact on stocking patterns, malaria knowledge and prescribing practices of shops/kiosks, but not consistently on other types of outlets. About 32% of shops receiving job aids prescribed to mystery shoppers the approved first-line drug, sulfadoxine-pyremethamine, as compared to only 3% of the control shops. In the first six months, it is estimated that 500 outlets were reached, at a cost of about $8000. Conclusions Changing private sector knowledge and practices is widely acknowledged to be slow and difficult. The vendor-to-vendor programme seems a feasible district-level strategy for achieving significant improvements in knowledge and practices of shops/kiosks. However, alternate strategies will be needed to influence pharmacies and clinics. Overall, the impact will be only moderate unless national policies and programmes are also introduced.

  4. Effect of Flow Configuration on Velocity and Temperature Distribution of Moderator Inside 540 MWe PHWR Calandria using CFD Techniques

    International Nuclear Information System (INIS)

    Bharj, J.S.; Sahaya, R.R.; Datta, D.; Dharne, S.P.

    2006-01-01

    The calandria of a Pressurized Heavy Water Reactor (PHWR) is a horizontal cylindrical vessel housing a matrix of horizontal tubes called calandria tubes, through which pass the pressure tubes that house the fuel bundles. The calandria is filled with heavy water acting as moderator. A large amount of heat (about 95 MW) is generated within the moderator mainly due to neutron slowing down and attenuation of gamma radiations. In the present configuration of 540 MWe calandria, moderator inlet diffusers are directed upwards and the outlet is from the bottom of the calandria. This configuration is not conducive for the buoyancy-dominated flows generated due to large volumetric heat generation in the moderator. In order to decide the effects of changes in flow configuration by changing location/direction of inlet/outlet nozzles, a study was done for moderator flows in the using PHOENICS CFD software. The results of study with various flow configurations show that modification in moderator flow configuration, reduces the peak temperature of moderator in calandria by about 12 deg C as well as gives a much more uniform temperature distribution. (authors)

  5. Tobacco retail outlet restrictions: health and cost impacts from multistate life-table modelling in a national population.

    Science.gov (United States)

    Pearson, Amber L; Cleghorn, Christine L; van der Deen, Frederieke S; Cobiac, Linda J; Kvizhinadze, Giorgi; Nghiem, Nhung; Blakely, Tony; Wilson, Nick

    2016-09-22

    Since there is some evidence that the density and distribution of tobacco retail outlets may influence smoking behaviours, we aimed to estimate the impacts of 4 tobacco outlet reduction interventions in a country with a smoke-free goal: New Zealand (NZ). A multistate life-table model of 16 tobacco-related diseases, using national data by sex, age and ethnicity, was used to estimate quality-adjusted life years (QALYs) gained and net costs over the remainder of the 2011 NZ population's lifetime. The outlet reduction interventions assumed that increased travel costs can be operationalised as equivalent to price increases in tobacco. All 4 modelled interventions led to reductions of >89% of current tobacco outlets after the 10-year phase-in process. The most effective intervention limited sales to half of liquor stores (and nowhere else) at 129 000 QALYs gained over the lifetime of the population (95% UI: 74 100 to 212 000, undiscounted). The per capita QALY gains were up to 5 times greater for Māori (indigenous population) compared to non-Māori. All interventions were cost-saving to the health system, with the largest saving for the liquor store only intervention: US$1.23 billion (95% UI: $0.70 to $2.00 billion, undiscounted). These tobacco outlet reductions reduced smoking prevalence, achieved health gains and saved health system costs. Effects would be larger if outlet reductions have additional spill-over effects (eg, smoking denormalisation). While these interventions were not as effective as tobacco tax increases (using the same model), these and other strategies could be combined to maximise health gain and to maximise cost-savings to the health system. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Fruit and vegetable intake in adolescents: SES and exposure to supermarkets and fast food outlets

    DEFF Research Database (Denmark)

    Svastisalee, Chalida; Holstein, Bjørn Evald; Due, Pernille

    backgrounds. Methods Data from the Health Behavior in School Aged Children Study (n = 6,034) were supplemented with geocoded information regarding supermarkets and fast food outlets, 300 meters from each school (n = 80). We used multilevel logistic regression to examine the relationship between infrequent...... fruit and vegetable intake and supermarket and fast food outlet concentration, stratifying by levels of family social class. Results Examining supermarket exposure alone, children from low social class backgrounds had the greatest odds of infrequent vegetable (OR = 1.50; CI: 1.03-2.20) and fruit (OR = 1.......43;CI: 1.06-1.93) intake, attending schools with low concentration of supermarkets. Children from low social class families attending schools with high fast food outlet and low supermarket concentration had the greatest odds of infrequent vegetable (OR = 1.79;CI: 0.99-3.21) and fruit (OR = 1.59; CI: 1...

  7. Is the number of fast-food outlets in the neighbourhood related to screen-detected type 2 diabetes mellitus and associated risk factors?

    Science.gov (United States)

    Bodicoat, Danielle H; Carter, Patrice; Comber, Alexis; Edwardson, Charlotte; Gray, Laura J; Hill, Sian; Webb, David; Yates, Thomas; Davies, Melanie J; Khunti, Kamlesh

    2015-06-01

    We investigated whether a higher number of fast-food outlets in an individual's home neighbourhood is associated with increased prevalence of type 2 diabetes mellitus and related risk factors, including obesity. Cross-sectional study. Three UK-based diabetes screening studies (one general population, two high-risk populations) conducted between 2004 and 2011. The primary outcome was screen-detected type 2 diabetes. Secondary outcomes were risk factors for type 2 diabetes. In total 10 461 participants (mean age 59 years; 53% male; 21% non-White ethnicity). There was a higher number of neighbourhood (500 m radius from home postcode) fast-food outlets among non-White ethnic groups (Pfast-food outlets was associated with significantly increased odds for diabetes (OR=1.02; 95% CI 1.00, 1.04) and obesity (OR=1.02; 95% CI 1.00, 1.03). This suggests that for every additional two outlets per neighbourhood, we would expect one additional diabetes case, assuming a causal relationship between the fast-food outlets and diabetes. These results suggest that increased exposure to fast-food outlets is associated with increased risk of type 2 diabetes and obesity, which has implications for diabetes prevention at a public health level and for those granting planning permission to new fast-food outlets.

  8. The effect of alcohol outlets, sales and trading hours on alcohol-related injuries presenting at emergency departments in Perth, Australia, from 2002 to 2010.

    Science.gov (United States)

    Hobday, Michelle; Chikritzhs, Tanya; Liang, Wenbin; Meuleners, Lynn

    2015-12-01

    Few studies have investigated the combined effects of alcohol sales, outlet numbers and trading hours on alcohol-related harms. This study aimed to test whether associations: (i) exist between alcohol-related emergency department (ED) injuries and alcohol sales and counts of outlets; (ii) vary between on- and off-premises outlets; and (iii) vary by trading hours conditions [extended trading permits (ETP) versus standard hours]. Panel study using 117 postcodes over 8 years (2002-10): 936 data points. Perth, Australia. ED injury presentations, aggregated to postcode-level. Alcohol-related injuries were identified using time-based surrogate measures: night injuries (n=51,241) and weekend night injuries (n=30,682). Measures of alcohol availability included number of outlets with standard and extended trading hours and mean sales per postcode. Negative binomial regression modelling with random effects was used to examine associations between availability and alcohol-related injury, controlling for socio-demographic characteristics. (i) Night injuries were associated significantly with counts of on-premises outlets [incident rate ratio (IRR)=1.046; 95% confidence interval (CI)=1.014-1.078] and sales per off-premises outlet (IRR=1.019; 95% CI=1.004-1.035); (ii) counts of on-premises outlets were positively associated with alcohol-related injury while counts of off-premises outlets indicated a negative association; and (iii) weekend night injuries increased by about 5% per on-premises outlet with an ETP (IRR=1.049; 95% CI=1.015-1.084) and by less than 1% for outlets with standard trading hours (IRR=1.008; 95% CI=1.004-1.013). Regions of Perth, Australia with greater off-premises alcohol sales and counts of on-premises alcohol outlets, particularly those with extended trading hours, appear to have higher levels of alcohol-related injuries. © 2015 Society for the Study of Addiction.

  9. Heat pump control method based on direct measurement of evaporation pressure to improve energy efficiency and indoor air temperature stability at a low cooling load condition

    International Nuclear Information System (INIS)

    Park, Young Sung; Jeong, Ji Hwan; Ahn, Byoung Ha

    2014-01-01

    Highlights: • New heat pump control method was developed. • Experimental investigation on performance of heat pump with various control method. • New control method appeared to improve the stability of indoor air temperature. • New control method appeared to have a potential to reduce power consumption. - Abstract: The control systems of conventional heat pumps have an input of refrigerant temperature at the evaporator outlet to maintain superheat at proper level. In order to develop a control method that can be used to achieve better indoor thermal comfort and energy efficiency at a low cooling load condition than the current control method, a new method of the evaporation pressure control based on the evaporator outlet pressure reading (EPCP) was developed. The changes in the stability of indoor air temperature and power consumption were measured while changing the compressor frequency in accordance with the new control method. Compared with the evaporation pressure control based on the evaporator outlet temperature reading, the EPCP control method appeared to improve the stability of room air temperature or occupant thermal comfort significantly

  10. Neighborhood Alcohol Outlet Density and Rates of Child Abuse and Neglect: Moderating Effects of Access to Substance Abuse Services

    Science.gov (United States)

    Morton, Cory M.; Simmel, Cassandra; Peterson, N. Andrew

    2014-01-01

    This study investigates the relationship between concentrations of on- and off-premises alcohol outlets and rates of child abuse and neglect. Additionally, the study seeks to locate protective features of a neighborhood's built environment by investigating the potentially moderating role that access to substance abuse treatment and prevention services plays in the relationship between alcohol outlet density and child maltreatment. Using a cross-sectional design, this ecological study utilized data from 163 census tracts in Bergen County, New Jersey, on reports of child abuse and neglect, alcohol outlets, substance abuse treatment and prevention facilities, and the United States Census to investigate the linkages between socioeconomic structure, alcohol availability, and access to substance abuse service facilities on rates of child abuse and neglect. Findings indicate areas with a greater concentration of on-premises alcohol outlets (i.e., bars) had higher rates of child neglect, and those with easier access to substance abuse services had lower rates of neglect, controlling for neighborhood demographic and socioeconomic structure. Additionally, the relationship between on-premises alcohol outlet density and rates of child neglect was moderated by the presence of substance abuse service facilities. A greater concentration of off-premises outlets (i.e., liquor stores) was associated with lower rates of physical abuse. Findings suggest that the built environment and socioeconomic structure of neighborhoods have important consequences for child well-being. The implications for future research on the structural features of neighborhoods that are associated with child well-being are discussed. PMID:24529493

  11. 7 CFR 987.56 - Outlets for utility and cull dates.

    Science.gov (United States)

    2010-01-01

    ..., utility dates and cull dates may be disposed of without inspection, but only in feed, non-table syrup... 7 Agriculture 8 2010-01-01 2010-01-01 false Outlets for utility and cull dates. 987.56 Section 987... DATES PRODUCED OR PACKED IN RIVERSIDE COUNTY, CALIFORNIA Order Regulating Handling Disposition of Other...

  12. Mass balance of Greenland's three largest outlet glaciers - 2000–2010

    NARCIS (Netherlands)

    Howat, I.M.; Ahn, Y.; Joughin, I.; van den Broeke, M.R.; Lenaerts, J.T.M.; Smith, B.

    2011-01-01

    Acceleration of Greenland's three largest outlet glaciers, Helheim, Kangerdlugssuaq and Jakobshavn Isbræ, accounted for a substantial portion of the ice sheet's mass loss over the past decade. Rapid changes in their discharge, however, make their cumulative mass-change uncertain. We derive monthly

  13. [Total pollution features of urban runoff outlet for urban river].

    Science.gov (United States)

    Luo, Hong-Bing; Luo, Lin; Huang, Gu; He, Qiang; Liu, Ping

    2009-11-01

    The urban stormwater runoff discharged to urban river, especially to rainfall source river, cannot be ignored. In this study, the Futian River watershed in Shenzhen city in a typical southern city of China is taken as the research object. In order to guide the pollution control for urban river, the eighteen rainfall events were monitored, and the total pollution features of the urban runoff outlet for this urban river were analyzed and discussed by using the process of pollutographs, the identifying to first flush, event mean concentration (EMC), etc. Results show that the concentrations of COD, SS, TN, TP and BOD5 are ten times more than the grade V of the environmental quality standards for surface water during the runoff time; the pollution caused by heavy metals (Cr, Ge, Cu, Hg and As) in runoff at a typical rainfall event is serious; the average and range of pollutant concentration at this runoff outlet in study area are evidently higher than at Shapingba in Chongqing city of China and at Silerwood in Canada, but are lower than at Shilipu in Wuhan city of China. The first flushes of COD, SS, BOD5, especially COD and SS, are evident, but the TN and TP are not. The average EMC of COD, TN, TP and BOD5 are 224.14, 571.15, 5.223, 2.04, 143.5 mg/L, respectively. To some extent, the EMC of COD is about two times of the value of the near cities, Macao and Zhuhai. The EMC of TN and TP are obviously higher than Beijing, Guangzhou and Shanghai. To compared with foreign counties, the EMC of the study area in Shenzhen is obviously much higher than the cities of Korean, USA and Canada. So the total pollution caused by the urban surface runoff in study area is serious and necessary to be treated.

  14. Brief report: Using global positioning system (GPS) enabled cell phones to examine adolescent travel patterns and time in proximity to alcohol outlets.

    Science.gov (United States)

    Byrnes, Hilary F; Miller, Brenda A; Morrison, Christopher N; Wiebe, Douglas J; Remer, Lillian G; Wiehe, Sarah E

    2016-07-01

    As adolescents gain freedom to explore new environments unsupervised, more time in proximity to alcohol outlets may increase risks for alcohol and marijuana use. This pilot study: 1) Describes variations in adolescents' proximity to outlets by time of day and day of the week, 2) Examines variations in outlet proximity by drinking and marijuana use status, and 3) Tests feasibility of obtaining real-time data to study adolescent proximity to outlets. U.S. adolescents (N = 18) aged 16-17 (50% female) carried GPS-enabled smartphones for one week with their locations tracked. The geographic areas where adolescents spend time, activity spaces, were created by connecting GPS points sequentially and adding spatial buffers around routes. Proximity to outlets was greater during after school and evening hours. Drinkers and marijuana users were in proximity to outlets 1½ to 2 times more than non-users. Findings provide information about where adolescents spend time and times of greatest risk, informing prevention efforts. Copyright © 2016 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  15. Low temperature distillation

    Energy Technology Data Exchange (ETDEWEB)

    Vandegrift, J N; Postel, C

    1929-04-09

    To recover gas, oil tars, and coked residues by low temperature distillation from bituminous coals, lignites, oil shales, and the like, the raw material is fed from a hopper into a rotary retort which is zonally heated, the temperature being greatest at the discharge end. The material is heated first to a relatively low temperature, thereby removing the moisture and lighter volatiles which are withdrawn through a pipe by the suction of a pump, while the higher boiling point volatiles and fixed gases are withdrawn by suction through an outlet from the higher temperature zone. The vapors withdrawn from the opposite ends of the retort pass through separate vapor lines and condensers, and the suction in each end of the retort, caused by the pumps, is controlled by valves, which also control the location of the neutral point in the retort formed by said suction. Air and inert gas may be introduced into the retort from pipe and stack respectively through a pipe, and steam may be admitted into the high temperature zone through a pipe.

  16. Heat removal performance of auxiliary cooling system for the high temperature engineering test reactor during scrams

    International Nuclear Information System (INIS)

    Takeda, Takeshi; Tachibana, Yukio; Iyoku, Tatsuo; Takenaka, Satsuki

    2003-01-01

    The auxiliary cooling system of the high temperature engineering test reactor (HTTR) is employed for heat removal as an engineered safety feature when the reactor scrams in an accident when forced circulation can cool the core. The HTTR is the first high temperature gas-cooled reactor in Japan with reactor outlet gas temperature of 950 degree sign C and thermal power of 30 MW. The auxiliary cooling system should cool the core continuously avoiding excessive cold shock to core graphite components and water boiling of itself. Simulation tests on manual trip from 9 MW operation and on loss of off-site electric power from 15 MW operation were carried out in the rise-to-power test up to 20 MW of the HTTR. Heat removal characteristics of the auxiliary cooling system were examined by the tests. Empirical correlations of overall heat transfer coefficients were acquired for a helium/water heat exchanger and air cooler for the auxiliary cooling system. Temperatures of fluids in the auxiliary cooling system were predicted on a scram event from 30 MW operation at 950 degree sign C of the reactor outlet coolant temperature. Under the predicted helium condition of the auxiliary cooling system, integrity of fuel blocks among the core graphite components was investigated by stress analysis. Evaluation results showed that overcooling to the core graphite components and boiling of water in the auxiliary cooling system should be prevented where open area condition of louvers in the air cooler is the full open

  17. High-temperature gas-cooled reactor: reformer application study

    International Nuclear Information System (INIS)

    1980-12-01

    This Application Study evaluates the HTGR-R with a core outlet temperature of 850 0 C as a near-term Lead Project and as a vehicle to long-term HTGR Program objectives. The scope of this effort included evaluation of the HTGR-R technology, evaluation of potential HTGR-R markets, assessment of the economics of commercial HTGR-R plants, and the evaluation of the program scope and expenditures necessary to establish HTGR-R technology through the completion of the Lead Project. In order to properly assess the potential of the HTGR-R and the suitability of the HTGR-R as a Lead Project, additional work must be performed before a final judgment is rendered. Design trade-off studies and alternative applications must be investigated to determine if a commercial potential exists for the HTGR-R at 850 0 C. If commercial incentives are only identified for the HTGR-R with core outlet temperatures greater than 850 0 C, the design and development program duration and cost and the demonstration path for the HTGR-R must be reassessed

  18. Case management of malaria fever in Cambodia: results from national anti-malarial outlet and household surveys

    Directory of Open Access Journals (Sweden)

    Littrell Megan

    2011-10-01

    Full Text Available Abstract Background Continued progress towards global reduction in morbidity and mortality due to malaria requires scale-up of effective case management with artemisinin-combination therapy (ACT. The first case of artemisinin resistance in Plasmodium falciparum was documented in western Cambodia. Spread of artemisinin resistance would threaten recent gains in global malaria control. As such, the anti-malarial market and malaria case management practices in Cambodia have global significance. Methods Nationally-representative household and outlet surveys were conducted in 2009 among areas in Cambodia with malaria risk. An anti-malarial audit was conducted among all public and private outlets with the potential to sell anti-malarials. Indicators on availability, price and relative volumes sold/distributed were calculated across types of anti-malarials and outlets. The household survey collected information about management of recent "malaria fevers." Case management in the public versus private sector, and anti-malarial treatment based on malaria diagnostic testing were examined. Results Most public outlets (85% and nearly half of private pharmacies, clinics and drug stores stock ACT. Oral artemisinin monotherapy was found in pharmacies/clinics (9%, drug stores (14%, mobile providers (4% and grocery stores (2%. Among total anti-malarial volumes sold/distributed nationally, 6% are artemisinin monotherapies and 72% are ACT. Only 45% of people with recent "malaria fever" reportedly receive a diagnostic test, and the most common treatment acquired is a drug cocktail containing no identifiable anti-malarial. A self-reported positive diagnostic test, particularly when received in the public sector, improves likelihood of receiving anti-malarial treatment. Nonetheless, anti-malarial treatment of reportedly positive cases is low among people who seek treatment exclusively in the public (61% and private (42% sectors. Conclusions While data on the anti

  19. Methodological Approaches to Locating Outlets of the Franchise Retail Network

    Directory of Open Access Journals (Sweden)

    Grygorenko Tetyana M.

    2016-08-01

    Full Text Available Methodical approaches to selecting strategic areas of managing the future location of franchise retail network outlets are presented. The main stages in the assessment of strategic areas of managing the future location of franchise retail network outlets have been determined and the evaluation criteria have been suggested. Since such selection requires consideration of a variety of indicators and directions of the assessment, the author proposes a scale of evaluation, which allows generalizing and organizing the research data and calculations of the previous stages of the analysis. The most important criteria and sequence of the selection of the potential franchisees for the franchise retail network have been identified, the technique for their evaluation has been proposed. The use of the suggested methodological approaches will allow the franchiser making sound decisions on the selection of potential target markets, minimizing expenditures of time and efforts on the selection of franchisees and hence optimizing the process of development of the franchise retail network, which will contribute to the formation of its structure.

  20. A Longitudinal Analysis of Cigarette Prices in Military Retail Outlets

    Science.gov (United States)

    Haddock, Christopher Keith; Hyder, Melissa L.; Poston, Walker S. C.; Jahnke, Sara A.; Williams, Larry N.; Lando, Harry

    2014-01-01

    Objectives. We conducted a longitudinal assessment of tobacco pricing in military retail outlets, including trends within each service branch. Methods. We determined the price of a single pack of Marlboro Red cigarettes at military retail stores located in the continental United States, Alaska, and Hawaii and at their nearest Walmarts in spring 2011 and 2013 (n = 128 for pairs available at both assessments). Results. The average difference between cigarettes sold in military retail outlets and Walmarts decreased from 24.5% in 2011 to 12.5% in 2013. The decrease was partially attributable to significant price decreases at Walmarts. The largest increases in cigarette prices occurred on naval installations. Potential savings at stores on several installations remained substantial in 2013; the largest approached $6 per pack. Stores on 17 military installations decreased cigarette prices during the study period. Conclusions. Tobacco can be purchased in military retail stores at substantial savings over civilian stores. If tobacco pricing is to cease to be an incentive for use among personnel, a revised military tobacco pricing policy is needed. PMID:24524503

  1. Neighborhood alcohol outlet density and rates of child abuse and neglect: moderating effects of access to substance abuse services.

    Science.gov (United States)

    Morton, Cory M; Simmel, Cassandra; Peterson, N Andrew

    2014-05-01

    This study investigates the relationship between concentrations of on- and off-premises alcohol outlets and rates of child abuse and neglect. Additionally, the study seeks to locate protective features of a neighborhood's built environment by investigating the potentially moderating role that access to substance abuse treatment and prevention services plays in the relationship between alcohol outlet density and child maltreatment. Using a cross-sectional design, this ecological study utilized data from 163 census tracts in Bergen County, New Jersey, on reports of child abuse and neglect, alcohol outlets, substance abuse treatment and prevention facilities, and the United States Census to investigate the linkages between socioeconomic structure, alcohol availability, and access to substance abuse service facilities on rates of child abuse and neglect. Findings indicate areas with a greater concentration of on-premises alcohol outlets (i.e., bars) had higher rates of child neglect, and those with easier access to substance abuse services had lower rates of neglect, controlling for neighborhood demographic and socioeconomic structure. Additionally, the relationship between on-premises alcohol outlet density and rates of child neglect was moderated by the presence of substance abuse service facilities. A greater concentration of off-premises outlets (i.e., liquor stores) was associated with lower rates of physical abuse. Findings suggest that the built environment and socioeconomic structure of neighborhoods have important consequences for child well-being. The implications for future research on the structural features of neighborhoods that are associated with child well-being are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Direct Numerical Simulations of Concentration and Temperature Polarization in Direct Contact Membrane Distillation

    Science.gov (United States)

    Lou, Jincheng; Tilton, Nils

    2017-11-01

    Membrane distillation (MD) is a method of desalination with boundary layers that are challenging to simulate. MD is a thermal process in which warm feed and cool distilled water flow on opposite sides of a hydrophobic membrane. The temperature difference causes water to evaporate from the feed, travel through the membrane, and condense in the distillate. Two challenges to MD are temperature and concentration polarization. Temperature polarization represents a reduction in the transmembrane temperature difference due to heat transfer through the membrane. Concentration polarization describes the accumulation of solutes near the membrane. These phenomena reduce filtration and lead to membrane fouling. They are difficult to simulate due to the coupling between the velocity, temperature, and concentration fields on the membrane. Unsteady regimes are particularly challenging because noise at the outlets can pollute the near-membrane flow fields. We present the development of a finite-volume method for the simulation of fluid flow, heat, and mass transport in MD systems. Using the method, we perform a parametric study of the polarization boundary layers, and show that the concentration boundary layer shows self-similar behavior that satisfies power laws for the downstream growth. Funded by the U.S. Bureau of Reclamation.

  3. The availability and accessibility of nutrition information in fast food outlets in five states post-menu labelling legislation in New South Wales.

    Science.gov (United States)

    Wellard, Lyndal; Havill, Michelle; Hughes, Clare; Watson, Wendy L; Chapman, Kathy

    2015-12-01

    1) Explore the availability and accessibility of fast food energy and nutrient information post-NSW menu labelling legislation in states with and without menu labelling legislation. 2) Determine whether availability and accessibility differed compared with pre-menu labelling legislation in NSW. We visited 210 outlets of the five largest fast food chains in five Australian states to observe the availability and accessibility of energy and nutrient information. Results were compared with 197 outlets surveyed pre-menu labelling. Most outlets (95%) provided energy values, half provided nutrient values and 3% provided information for all menu items. The total amount of information available increased post-NSW menu labelling implementation (473 versus 178 pre-implementation, pFast food chains surveyed had voluntarily introduced menu labelling nationally. However, more nutrient information was available in-store in 2010, showing that fast food chains are able to provide comprehensive nutrition information, yet they have stopped doing so. Menu labelling legislation should compel fast food chains to provide accessible nutrition information including nutrient values in addition to energy for all menu items in-store. Additionally, public education campaigns are needed to ensure customers can use menu labelling. © 2015 Public Health Association of Australia.

  4. Characterization of elevated temperature properties of heat exchanger and steam generator alloys

    International Nuclear Information System (INIS)

    Wright, J.K.; Carroll, L.J.; Cabet, C.; Lillo, T.M.; Benz, J.K.; Simpson, J.A.; Lloyd, W.R.; Chapman, J.A.; Wright, R.N.

    2012-01-01

    The Next Generation Nuclear Plant project is considering Alloy 800H and Alloy 617 for steam generator and intermediate heat exchangers. It is envisioned that a steam generator would operate with reactor outlet temperatures from 750 to 800 °C, while an intermediate heat exchanger for primary to secondary helium would operate up to an outlet temperature of 950 °C. Although both alloys are of interest due in part to their technical maturity, a number of specific properties require further characterization for design of nuclear components. Strain rate sensitivity of both alloys has been characterized and is found to be significant above 600 °C. Both alloys also exhibit dynamic strain aging, characterized by serrated flow, over a wide range of temperatures and strain rates. High temperature tensile testing of Alloy 617 and Alloy 800H has been conducted over a range of temperatures. Dynamic strain aging is a concern for these materials since it is observed to result in reduced ductility for many solid solution alloys. Creep, fatigue, and creep–fatigue properties of Alloy 617 have been measured as well, with the goal of determining the influence of the temperature, strain rate and atmosphere on the creep–fatigue life of Alloy 617. Elevated temperature properties and implications for codification of the alloys will be described.

  5. Frequency, triggering factors and possible consequences of mass movements on outlet glaciers in Iceland.

    Science.gov (United States)

    Saemundsson, Thorsteinn; Margeirsson, Guðbjörn

    2016-04-01

    During the last 15 years several mass movements of various size and origin, e.g. rock avalanches, rock slides and debris slides have been observed to have fall on outlet glaciers in Iceland. This should not come as a surprise in this type of glacial environment, but in a way it does. When looking at the history only few mass movements are recorded to have fall on outlet glaciers in Iceland, during the decades before the year 2000 or since 1960. This "lack of mass movements" can be explained by the fact that fewer observations and monitoring were done in the past, but is it so or are we seeing increasing activity? Looking at the distribution of the known mass movements, two activity periods cam be identified. The former one around 1970 and the second one starting around 2000 and is still ongoing. Both of these periods are characterized by warmer climate leading to retreating phases of glaciers. Two larger mass movements are known from these two retreating periods. The former one occurred in January 1967. Then a large rockslide fell on the snout and into the glacial lake of the Steinholtsjökull outlet glacier in the northern side of the Eyjafjallajökull ice cap. The rockslide broke up the snout of the glacier and caused large floodwave bursting down the Steinholtsdalur valley transporting large volume of sediments down its path. The later one occurred in 2007, when a large rockavalanche fell on the Morsárjökull outlet glacier, in the southern side of the Vatnajökull ice cap. The avalanche debris covered around 1/5 of the glacier surface. Today the retreat and thinning of glaciers in Iceland are extremely rapid. The consequences of such a rapid retreat are e.g. unstable valley slopes surrounding the outlet glaciers, both in loose sediments and bedrock, thawing of mountain permafrost and not least formation of glacial lakes in front of the rapid retreating ice margins. Such conditions can become extremely hazardous, as seen by the above mentioned examples, both

  6. Characterising and comparing drug-dispensing practices at animal health outlets in the Rift Valley, Kenya: an exploratory analysis (part II).

    Science.gov (United States)

    Higham, L E; Ongeri, W; Asena, K; Thrusfield, M V

    2016-12-01

    A mixed-method study was conducted in the Rift Valley of Kenya to characterise drug-dispensing practices amongst staff at animal health outlets and to explore perceptions of veterinary medicines amongst pastoralists and farmers. Forty structured questionnaires were administered to staff at animal health outlets, including franchise outlets of 'Sidai Africa Ltd.', and two focus group discussions were facilitated to explore the perceptions of local animal health services by a Maasai pastoralist group and a dairy farmer cooperative. Differences were detected in the characteristics of Sidai outlets, agrovets, pharmacies and dukas. A greater proportion of Sidai outlet staff selected drugs based on principles of responsible drug use than staff at other types of outlet, and technical qualifications and training were associated with responsible drug use. Across all outlet types, staff knowledge and training gaps were identified, including in the correct administration of medicines. The majority of drug sales are accompanied by verbal advice to farmers. Members of the Maasai pastoralist group were concerned about accidental self-medication, withdrawal periods, drug residues and the misuse of drugs due to a lack of quality information and advice. The dairy farmer group raised similar concerns, reporting under-dosing as a common mistake amongst farmers. This study concludes that current knowledge, attitudes and practices of many service providers and livestock owners in the sale, purchase and use of veterinary medicines present risks of drug misuse and therefore the emergence of antimicrobial resistance. There is a clear demand from livestock keepers for accessible, affordable and quality animal health services and products in Kenya, and animal health practitioners have the potential to provide increased support to livestock-based livelihoods and act as stewards of our existing portfolio of animal and human medicines.

  7. Greater access to fast-food outlets is associated with poorer bone health in young children.

    Science.gov (United States)

    Vogel, C; Parsons, C; Godfrey, K; Robinson, S; Harvey, N C; Inskip, H; Cooper, C; Baird, J

    2016-03-01

    A healthy diet positively influences childhood bone health, but how the food environment relates to bone development is unknown. Greater neighbourhood access to fast-food outlets was associated with lower bone mass among infants, while greater access to healthy speciality stores was associated with higher bone mass at 4 years. Identifying factors that contribute to optimal childhood bone development could help pinpoint strategies to improve long-term bone health. A healthy diet positively influences bone health from before birth and during childhood. This study addressed a gap in the literature by examining the relationship between residential neighbourhood food environment and bone mass in infants and children. One thousand one hundred and seven children participating in the Southampton Women's Survey, UK, underwent measurement of bone mineral density (BMD) and bone mineral content (BMC) at birth and 4 and/or 6 years by dual-energy X-ray absorptiometry (DXA). Cross-sectional observational data describing food outlets within the boundary of each participant's neighbourhood were used to derive three measures of the food environment: the counts of fast-food outlets, healthy speciality stores and supermarkets. Neighbourhood exposure to fast-food outlets was associated with lower BMD in infancy (β = -0.23 (z-score): 95% CI -0.38, -0.08) and lower BMC after adjustment for bone area and confounding variables (β = -0.17 (z-score): 95% CI -0.32, -0.02). Increasing neighbourhood exposure to healthy speciality stores was associated with higher BMD at 4 and 6 years (β = 0.16(z-score): 95% CI 0.00, 0.32 and β = 0.13(z-score): 95% CI -0.01, 0.26 respectively). The relationship with BMC after adjustment for bone area and confounding variables was statistically significant at 4 years, but not at 6 years. The neighbourhood food environment that pregnant mothers and young children are exposed may affect bone development during early childhood. If confirmed in

  8. High temperature reactors for cogeneration applications

    Energy Technology Data Exchange (ETDEWEB)

    Verfondern, Karl [Forschungszentrum Juelich (Germany). IEK-6; Allelein, Hans-Josef [Forschungszentrum Juelich (Germany). IEK-6; RWTH Aachen (Germany). Lehrstuhl fuer Reaktorsicherheit und -technik (LRST)

    2016-05-15

    There is a large potential for nuclear energy also in the non-electric heat market. Many industrial sectors have a high demand for process heat and steam at various levels of temperature and pressure to be provided for desalination of seawater, district heating, or chemical processes. The future generation of nuclear plants will be capable to enter the wide field of cogeneration of heat and power (CHP), to reduce waste heat and to increase efficiency. This requires an adjustment to multiple needs of the customers in terms of size and application. All Generation-IV concepts proposed are designed for coolant outlet temperatures above 500 C, which allow applications in the low and medium temperature range. A VHTR would even be able to cover the whole temperature range up to approx. 1 000 C.

  9. Some problems on materials tests in high temperature hydrogen base gas mixture

    International Nuclear Information System (INIS)

    Shikama, Tatsuo; Tanabe, Tatsuhiko; Fujitsuka, Masakazu; Yoshida, Heitaro; Watanabe, Ryoji

    1980-01-01

    Some problems have been examined on materials tests (creep rupture tests and corrosion tests) in high temperature mixture gas of hydrogen (80%H 2 + 15%CO + 5%CO 2 ) simulating the reducing gas for direct steel making. H 2 , CO, CO 2 and CH 4 in the reducing gas interact with each other at elevated temperature and produce water vapor (H 2 O) and carbon (soot). Carbon deposited on the walls of retorts and the water condensed at pipings of the lower temperature gas outlet causes blocking of gas flow. The gas reactions have been found to be catalyzed by the retort walls, and appropriate selection of the materials for retorts has been found to mitigate the problems caused by water condensation and carbon deposition. Quartz has been recognized to be one of the most promising materials for minimizing the gas reactions. And ceramic coating, namely, BN (born nitride) on the heat resistant superalloy, MO-RE II, has reduced the amounts of water vapor and deposited carbon (sooting) produced by gas reactions and has kept dew points of outlet gas below room temperature. The well known emf (thermo-electromotive force) deterioration of Alumel-Chromel thermocouples in the reducing gases at elevated temperatures has been also found to be prevented by the ceramic (BN) coating. (author)

  10. UO{sub 2} and PuO{sub 2} utilization in high temperature engineering test reactor with helium coolant

    Energy Technology Data Exchange (ETDEWEB)

    Waris, Abdul, E-mail: awaris@fi.itb.ac.id; Novitrian,; Pramuditya, Syeilendra; Su’ud, Zaki [Nuclear Physics and Biophysics Research Division, Department of Physics, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung (Indonesia); Aji, Indarta K. [Department of Physics, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung (Indonesia)

    2016-03-11

    High temperature engineering test reactor (HTTR) is one of high temperature gas cooled reactor (HTGR) types which has been developed by Japanese Atomic Energy Research Institute (JAERI). The HTTR is a graphite moderator, helium gas coolant, 30 MW thermal output and 950 °C outlet coolant temperature for high temperature test operation. Original HTTR uses UO{sub 2} fuel. In this study, we have evaluated the use of UO{sub 2} and PuO{sub 2} in form of mixed oxide (MOX) fuel in HTTR. The reactor cell calculation was performed by using SRAC 2002 code, with nuclear data library was derived from JENDL3.2. The result shows that HTTR can obtain its criticality condition if the enrichment of {sup 235}U in loaded fuel is 18.0% or above.

  11. [Eleven Patients with Gastric Cancer Who Received Chemotherapy after Stent Placement for Gastric Outlet Obstruction].

    Science.gov (United States)

    Endo, Shunji; Nakagawa, Tomo; Konishi, Ken; Ikenaga, Masakazu; Ohta, Katsuya; Nakashima, Shinsuke; Matsumoto, Kenichi; Nishikawa, Kazuhiro; Ohmori, Takeshi; Yamada, Terumasa

    2017-01-01

    Endoscopic placement of self-expandable metallic stents is reportedly effective for gastric outlet obstructions due to advanced gastric cancer, and is less invasive than gastrojejunostomy. For patients who have good performance status, we administer chemotherapy after stent placement, although the safety and feasibility of this chemotherapy have not yet been discussed in full. Between 2011 and 2015, 15 patients at our institution underwent endoscopic gastroduodenal stent placement for gastric outlet obstruction due to gastric cancer. Eleven of these patients were administered chemotherapy after stent placement. In our case series, we did not observe any specific adverse event caused by stent placement plus chemotherapy. Adverse events after chemotherapy included anemia of CTCAE Grade 3 in 7 patients. Stent-in-stent placement was needed in 2 patients. Neither stent migration nor perforation was observed. Therefore, chemotherapy after stent placement for gastric outlet obstruction due to gastric cancer was considered safe and feasible. Stent placement is useful not only as palliative care for patients with terminal-stage disease, but also as one of the multimodal therapeutic strategies for gastric cancer.

  12. Combustion Dynamic Characteristics Identification in a 9-point LDI Combustor Under Choked Outlet Boundary Conditions

    Science.gov (United States)

    He, Zhuohui J.; Chang, Clarence T.

    2017-01-01

    Combustion dynamics data were collected at the NASA Glenn Research Center's CE-5 flame tube test facility under combustor outlet choked conditions. Two 9-point Swirl-Venturi Lean Direct Injection (SV-LDI) configurations were tested in a rectangular cuboid combustor geometry. Combustion dynamic data were measured at different engine operational conditions up to inlet air pressure and temperature of 24.13 bar and 828 K, respectively. In this study, the effects of acoustic cavity resonance, precessing vortex core (PVC), and non-uniform thermal expansion on the dynamic noise spectrum are identified by comparing the dynamic data that collected at various combustor inlet conditions along with combustor geometric calculations. The results show that the acoustic cavity resonance noises were seen in the counter-rotating pilot configuration but not in the co-rotating pilot configuration. Dynamic pressure noise band at around 0.9 kHz was only detected at the P'41 location (9.8 cm after fuel injector face) but not at the P'42 location (29 cm after the fuel injector face); the amplitude of this noise band depended on the thermal expansion ratio (T4/T3). The noise band at around 1.8 kHz was found to depend on the inlet air pressure or the air density inside the combustor. The PVC frequency was not observed in these two configurations.

  13. High Temperature Falling Particle Receiver (2012 - 2016) - Final DOE Report

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Clifford K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-04-15

    The objective of this work was to advance falling particle receiver designs for concentrating solar power applications that will enable higher temperatures (>700 °C) and greater power-cycle efficiencies (≥50% thermal-to-electric). Modeling, design, and testing of components in Phases 1 and 2 led to the successful on-sun demonstration in Phase 3 of the world’s first continuously recirculating high-temperature 1 MWt falling particle receiver that achieved >700 °C particle outlet temperatures at mass flow rates ranging from 1 – 7 kg/s.

  14. Effect of cross-flow direction of coolant on film cooling effectiveness with one inlet and double outlet hole injection

    Directory of Open Access Journals (Sweden)

    Guangchao Li

    2012-12-01

    Full Text Available In order to study the effect of cross-flow directions of an internal coolant on film cooling performance, the discharge coefficients and film cooling effectiveness with one inlet and double outlet hole injections were simulated. The numerical results show that two different cross-flow directions of the coolant cause the same decrease in the discharge coefficients as that in the case of supplying coolant by a plenum. The different proportion of the mass flow out of the two outlets of the film hole results in different values of the film cooling effectiveness for three different cases of coolant supplies. The film cooling effectiveness is the highest for the case of supplying coolant by the plenum. At a lower blowing ratio of 1.0, the film cooling effectiveness with coolant injection from the right entrance of the passage is higher than that from the left entrance of the passage. At a higher blowing ratio of 2.0, the opposite result is found.

  15. Laparoscopic gastrojejunostomy versus duodenal stenting in unresectable gastric cancer with gastric outlet obstruction.

    Science.gov (United States)

    Min, Sa-Hong; Son, Sang-Yong; Jung, Do-Hyun; Lee, Chang-Min; Ahn, Sang-Hoon; Park, Do Joong; Kim, Hyung-Ho

    2017-09-01

    To compare the outcome between laparoscopic gastrojejunostomy (LapGJ) and duodenal stenting (DS) in terms of oral intake, nutritional status, patency duration, effect on chemotherapy and survival. Medical records of 115 patients, who had LapGJ or duodenal stent placement between July 2005 and September 2015 in Seoul National University Bundang Hospital, have been reviewed retrospectively. Oral intake was measured with Gastric Outlet Obstruction Scoring System. Serum albumin and body weight was measured as indicators of nutritional status. The duration of patency was measured until the date of reintervention. Chemotherapy effect was calculated after the procedures. Survival period and oral intake was analyzed by propensity score matching age, sex, T-stage, comorbidities, and chemotherapy status. Forty-three LapGJ patients and 58 DS patients were enrolled. Improvement in oral intake was shown in LapGJ group versus DS group (88% vs. 59%, P = 0.011). Serum albumin showed slight but significant increase after LapGJ (+0.75 mg/dL vs. -0.15 mg/dL, P = 0.002); however, there was no difference in their body weight (+5.1 kg vs. -1.0 kg, P = 0.670). Patients tolerated chemotherapy longer without dosage reduction after LapGJ (243 days vs . 74 days, P = 0.006) and maintained the entire chemotherapy regimen after the procedure longer in LapGJ group (247 days vs. 137 days, P = 0.042). LapGJ showed significantly longer survival than DS (220 vs. 114 days, P = 0.004). DS can provide faster symptom relief but LapGJ can provide improved oral intake, better compliance to chemotherapy, and longer survival. Therefore, LapGJ should be the first choice in gastric outlet obstruction patients for long-term and better quality of life.

  16. CFD Analysis of Hot Spot Fuel Temperature in the Control Fuel Block Assembly of a VHTR core

    International Nuclear Information System (INIS)

    Kim, Min Hwan; Tak, Nam Il; Noh, Jae Man

    2010-01-01

    The Very High Temperature Reactor (VHTR) dedicated for efficient hydrogen production requires core outlet temperatures of more than 950 .deg. C. As the outlet temperature increases, the thermal margin of the core decreases, which highlights the need for a detailed analysis to reduce its uncertainty. Tak et al. performed CFD analysis for a 1/12 fuel assembly model and compared the result with a simple unit-cell model in order to emphasize the need of a detailed CFD analysis for the prediction of hot spot fuel temperatures. Their CFD model, however, was focused on the standard fuel assembly but not on the control fuel assembly in which a considerable amount of bypass flow is expected to occur through the control rod passages. In this study, a CFD model for the control fuel block assembly is developed and applied for the hot spot analyses of PMR200 core. Not only the bypass flow but also the cross flow is considered in the analyses

  17. Detection and Repair of Ligament Cracks in a 109mm Thick Superheater Outlet Header

    International Nuclear Information System (INIS)

    Day, Peter

    2006-01-01

    Conventional thermal power station boilers are constructed of drums and a series of headers which are interconnected with many hundreds of tubes. Typically feed water enters the boiler at about 250 deg C at a pressure of around 250 bar with steam outlet temperatures of 540 deg C and a pressure of 170 bar. Superheater outlet headers may be subjected to quite arduous conditions during service. Not only are they exposed to high pressure stresses but also to high thermal stresses due to varying thermal gradients through the section thickness particularly at start up and during two shift operation. The area that is exposed to the greatest thermal gradients is the narrow ligament that exists between the tube hole penetrations in the header bore. In the mid the 1980's industry wide surveys found cracking in a large percentage (25-50%) of headers after 15 years of service. Detection and sizing of ligament cracking and estimates of the rate of growth are therefore a major consideration especially in plant that is two shifted. In order to manage the risk both remote visual and ultrasonic inspection are performed during each major unit overhaul. Conclusion: Ultrasonic techniques used for this inspection need to be carefully evaluated with respect to their effectiveness. Conventional pulse echo is capable of detection but using for example a technique such as AS2207 level 1 will not show the defect size. Time of flight diffraction has shown itself to be effective in accurately sizing ligament cracking. However the complex geometry of header ligaments appears to cause a narrowing of the beam with the effect that crack tip responses can be concentrated at the centre of the ligament. Therefore great care needs to be taken during data interrogation because errors in sizing can occur. Wherever possible both 'B' and 'D' scan data should be collected. It appears that the greatest accuracy is obtained with respect to defect growth from the B scan image. With respect to the welding a

  18. Geographic Accessibility Of Food Outlets Not Associated With Body Mass Index Change Among Veterans, 2009-14.

    Science.gov (United States)

    Zenk, Shannon N; Tarlov, Elizabeth; Wing, Coady; Matthews, Stephen A; Jones, Kelly; Tong, Hao; Powell, Lisa M

    2017-08-01

    In recent years, various levels of government in the United States have adopted or discussed subsidies, tax breaks, zoning laws, and other public policies that promote geographic access to healthy food. However, there is little evidence from large-scale longitudinal or quasi-experimental research to suggest that the local mix of food outlets actually affects body mass index (BMI). We used a longitudinal design to examine whether the proximity of food outlets, by type, was associated with BMI changes between 2009 and 2014 among 1.7 million veterans in 382 metropolitan areas. We found no evidence that either absolute or relative geographic accessibility of supermarkets, fast-food restaurants, or mass merchandisers was associated with changes in an individual's BMI over time. While policies that alter only geographic access to food outlets may promote equitable access to healthy food and improve nutrition, our findings suggest they will do little to combat obesity in adults. Project HOPE—The People-to-People Health Foundation, Inc.

  19. Associations between childhood obesity and the availability of food outlets in the local environment: a retrospective cross-sectional study.

    Science.gov (United States)

    Miller, Laura J; Joyce, Sarah; Carter, Shannon; Yun, Grace

    2014-01-01

    Examine whether individual-level childhood obesity is related to residential availability of fast food and healthy food outlets. Retrospective cross-sectional study. Perth, Western Australia. A total of 1850 children aged 5 to 15 years in 2005-2010 who participated in the Western Australian Health and Wellbeing Surveillance System survey. Geographical Information Systems were used to calculate a range of measures of fast food and healthy food outlet access and availability. For example, distance to nearest and access and density measures within 800 m and 3 km of each child's residence were all tested. Multivariate logistic regression analysis, controlling for individual-level sociodemographic factors and lifestyle behaviors. An increasing number of healthy food outlets within 800 m of a child's home was associated with a significantly reduced risk of being overweight/obese in all models tested. After controlling for age, physical activity, time spent sedentary, weekly takeaway consumption, area disadvantage, and count of fast food outlets, each additional healthy food outlet within 800 m was associated with a 20% decrease in the likelihood of a child being overweight or obese (odds ratio: .800, 95% confidence intervals: .686-.933). The local food environment around children's homes has an independent effect on child weight status. These findings highlight the importance of the built environment as a potential contributor towards child health, which should be considered when developing community health promotion programs.

  20. Climatology, hydrology, and simulation of an emergency outlet, Devils Lake basin, North Dakota

    Science.gov (United States)

    Wiche, Gregg J.; Vecchia, A.V.; Osborne, Leon; Wood, Carrie M.; Fay, James T.

    2000-01-01

    Devils Lake is a natural lake in northeastern North Dakota that is the terminus of a nearly 4,000-square-mile subbasin in the Red River of the North Basin. The lake has not reached its natural spill elevation to the Sheyenne River (a tributary of the Red River of the North) in recorded history. However, geologic evidence indicates a spill occurred sometime within the last 1,800 years. From 1993 to 1999, Devils Lake rose 24.5 feet and, at the present (August 2000), is about 13 feet below the natural spill elevation. The recent lake-level rise has caused flood damages exceeding $300 million and triggered development of future flood-control options to prevent further infrastructure damage and reduce the risk of a potentially catastrophic uncontrolled spill. Construction of an emergency outlet from the west end of Devils Lake to the Sheyenne River is one flood-control option being considered. This report describes the climatologic and hydrologic causes of the recent lake level rise, provides information on the potential for continued lake-level rises during the next 15 years, and describes the potential effectiveness of an emergency outlet in reducing future lake levels and in reducing the risk of an uncontrolled spill. The potential effects of an outlet on downstream water quantity and quality in the upper Sheyenne River also are described.

  1. Baseline Concept Description of a Small Modular High Temperature Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Gougar, Hans D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-10-01

    The objective of this report is to provide a description of generic small modular high temperature reactors (herein denoted as an smHTR), summarize their distinguishing attributes, and lay out the research and development (R&D) required for commercialization. The generic concepts rely heavily on the modular high temperature gas-cooled reactor designs developed in the 1980s which were never built but for which pre-licensing or certification activities were conducted. The concept matured more recently under the Next Generation Nuclear Plant (NGNP) project, specifically in the areas of fuel and material qualification, methods development, and licensing. As all vendor-specific designs proposed under NGNP were all both ‘small’ or medium-sized and ‘modular’ by International Atomic Energy Agency (IAEA) and Department of Energy (DOE) standards, the technical attributes, challenges, and R&D needs identified, addressed, and documented under NGNP are valid and appropriate in the context of Small Modular Reactor (SMR) applications. Although the term High Temperature Reactor (HTR) is commonly used to denote graphite-moderated, thermal spectrum reactors with coolant temperatures in excess of 650oC at the core outlet, in this report the historical term High Temperature Gas-Cooled Reactor (HTGR) will be used to distinguish the gas-cooled technology described herein from its liquid salt-cooled cousin. Moreover, in this report it is to be understood that the outlet temperature of the helium in an HTGR has an upper limit of 950 degrees C which corresponds to the temperature to which certain alloys are currently being qualified under DOE’s ARC program. Although similar to the HTGR in just about every respect, the Very High Temperature Reactor (VHTR) may have an outlet temperature in excess of 950 degrees C and is therefore farther from commercialization because of the challenges posed to materials exposed to these temperatures. The VHTR is the focus of R&D under the

  2. Baseline Concept Description of a Small Modular High Temperature Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hans Gougar

    2014-05-01

    The objective of this report is to provide a description of generic small modular high temperature reactors (herein denoted as an smHTR), summarize their distinguishing attributes, and lay out the research and development (R&D) required for commercialization. The generic concepts rely heavily on the modular high temperature gas-cooled reactor designs developed in the 1980s which were never built but for which pre-licensing or certification activities were conducted. The concept matured more recently under the Next Generation Nuclear Plant (NGNP) project, specifically in the areas of fuel and material qualification, methods development, and licensing. As all vendor-specific designs proposed under NGNP were all both ‘small’ or medium-sized and ‘modular’ by International Atomic Energy Agency (IAEA) and Department of Energy (DOE) standards, the technical attributes, challenges, and R&D needs identified, addressed, and documented under NGNP are valid and appropriate in the context of Small Modular Reactor (SMR) applications. Although the term High Temperature Reactor (HTR) is commonly used to denote graphite-moderated, thermal spectrum reactors with coolant temperatures in excess of 650oC at the core outlet, in this report the historical term High Temperature Gas-Cooled Reactor (HTGR) will be used to distinguish the gas-cooled technology described herein from its liquid salt-cooled cousin. Moreover, in this report it is to be understood that the outlet temperature of the helium in an HTGR has an upper limit of 950 degrees C which corresponds to the temperature to which certain alloys are currently being qualified under DOE’s ARC program. Although similar to the HTGR in just about every respect, the Very High Temperature Reactor (VHTR) may have an outlet temperature in excess of 950 degrees C and is therefore farther from commercialization because of the challenges posed to materials exposed to these temperatures. The VHTR is the focus of R&D under the

  3. Computer-Aided Simulations of Convective Heat Transfer in a Wedged Channel with Pin-Fins at Various Outlet Arrangements and Nonuniform Diameters

    Directory of Open Access Journals (Sweden)

    Qitao Zhou

    2013-01-01

    Full Text Available The turbine blade works at high thermal loads, especially the trailing edge of the blade due to the hot gas leakage flow. Pin-fins are well recognized as a kind of effective device to augment the convective heat transfer and effectively cool the trailing edge. In this paper, the cooling effectiveness of chordwise outlet pin-fins distance and inner pin fin diameter is, respectively, studied on the heat transfer and flow friction of the trailing edge of the blade with software CFX. A 90 deg turn cooling wedge passage with cylindrical pin-fins is used to model the trailing edge. Results show that the pin-fins distance at the outlet and the arithmetic arrangement of the inner pin-fins diameter both are vital factors to influence the cooling effectiveness in the trailing edge of the blade.

  4. Three-dimensional stereology as a tool for evaluating bladder outlet obstruction

    DEFF Research Database (Denmark)

    Van Der Wijk, Jasper; Van Der Wijk, Jan; Horn, Thomas

    2008-01-01

    Objective. In a pilot study we evaluated whether implementation of a novel 3D stereologic technique can prove that bladder outlet obstruction (BOO) is associated with morphologic changes in the bladder wall. Material and methods. Ten males (mean age 69.7 years; range 58-84 years) with lower urinary...... tract symptoms (LUTS) suggestive of BOO and five controls (mean age 48.6 years; range 43-53 years) without LUTS were studied. All participants underwent a full examination, including determination of the International Prostate Symptom Score, laboratory analysis and a urodynamic evaluation. A cold....... Conclusions. This pilot study shows that, even with the implementation of subtle morphometric techniques, there seems to be no relationship between the severity of BOO and bladder wall morphology. It is possible that interstitial collagen in the bladder wall increases with age. It seems that bladder wall...

  5. Sodium steam generator within which are inlet and outlet ducts with pipe bundles in vessel

    International Nuclear Information System (INIS)

    1980-01-01

    The sodium steam generator with internal flow ducts for inlet and outlet to a vessel are provided as pipe bundles in the form of helically wound concentric layers terminating in inlet and outlet connections with chambers, characterised in that within the vessel, the pipe pieces which are connected to the pipe windings with the said vessel are arranged in substantially radially aligned rows so that each row measured in the circumferential direction at least on one side is at a spacing from the following row sufficiently large that between the rows or groups of rows an open sector is provided. (G.C.)

  6. Alcohol outlets near schools in a midsize Romanian city. Prevalence and chararteristics

    NARCIS (Netherlands)

    van Hoof, Joris Jasper; Reijlink, Lian M.J.; van Dalen, Wim E.

    2010-01-01

    Objective: alcohol availability is one of the strongest predictors of adolescent alcohol use, and subsequent harm. Alcohol outlets near schools are an important indicator of three types of availability related to adolescent alcohol use; physical (number), economic (price), and legal (compliance with

  7. Requirements under decree 430 UJD for unit outlet and standby power supply

    International Nuclear Information System (INIS)

    Vanco, K.

    2012-01-01

    At present, the nuclear power plants are only sufficient resources, which can cover a huge demand for electricity. Concentration so huge power in one place require adequate security from the perspective lead power outlet and standby power supply of reactor unit. (Author)

  8. Positioning invasive versus noninvasive urodynamics in the assessment of bladder outlet obstruction

    NARCIS (Netherlands)

    Arnolds, Michiel; Oelke, Matthias

    2009-01-01

    Purpose of review To provide evidence of promising tests to noninvasively diagnose bladder outlet obstruction (800) in men with benign prostatic hyperplasia. Recent findings Pressure-flow studies are usually performed to prove BOO prior to prostatectomy. However, pressure-flow studies are invasive,

  9. Low temperature distillation of powdered materials

    Energy Technology Data Exchange (ETDEWEB)

    1929-04-11

    In the low temperature distillation of powdered material such as coal, brown coal, or oil shale, dust carried by the gases and vapors is precipitated by supplying liquid hydrocarbons to the effluent gases, for example, to a dust remover through which the distillates pass. The material is supplied through a hopper and moved through a retort by a worm feed, and is discharged into a sump. Scavenging gases such as steam may be introduced through a pipe. Two conveyor worms moving in opposite directions are provided in an outlet conduit which may be surrounded by a cooling jacket. Heavy hydrocarbons condense on the walls of the conduit and on the conveyor worms and serve as dust catchers for the distillates, the lighted volatiles escaping through an outlet. The high boiling point oils flow back to and are cracked in the retort. Oils such as tar oils may be sprayed into the conduit or directly adjacent the entry of the material from feeding hopper.

  10. Supraclavicular scalenectomy for thoracic outlet syndrome--functional outcomes assessed using the DASH scoring system.

    LENUS (Irish Health Repository)

    Glynn, Ronan W

    2012-02-01

    To evaluate supraclavicular scalenectomy ± cervical rib excision for thoracic outlet syndrome (TOS), employing Disability of Arm, Shoulder, and Hand (DASH) scoring for functional assessment post-decompression.

  11. Electrical Power Quality - What's Behind the Outlet?

    Science.gov (United States)

    Baird, William H.; Secrest, Jeffery; Padgett, Clifford

    2017-09-01

    Although we may consider the power outlets in our homes to be nearly ideal voltage sources, a variety of influences in and around the home can cause departures from the nominal 60 Hz, 110-120 V root-mean-square (rms) of the North American grid. Even without instrumentation, we can see that a large motor starting from rest can be sufficient to cause lights to dim momentarily (voltage sag). This dimming is due to the inrush current drawn by a stationary motor, which may be several times the current drawn at operating speed. We prepared a voltage monitoring system using a voltage divider, the construction details of which we omit in the interest of safety.

  12. Biomass bale stack and field outlet locations assessment for efficient infield logistics

    Science.gov (United States)

    Harvested hay or biomass are traditionally baled for better handling and they are transported to the outlet for final utilization. For better management of bale logistics, producers often aggregate bales into stacks so that bale-hauling equipment can haul multiple bales for improved efficiency. Obje...

  13. Prolapsing Gastric Polyp Causing Intermittent Gastric Outlet Obstruction.

    Science.gov (United States)

    Kosai, Nik Ritza; Gendeh, Hardip Singh; Norfaezan, Abdul Rashid; Razman, Jamin; Sutton, Paul Anthony; Das, Srijit

    2015-06-01

    Gastric polyps are often an incidental finding on upper gastrointestinal endoscopy, with an incidence up to 5%. The majority of gastric polyps are asymptomatic, occurring secondary to inflammation. Prior reviews discussed Helicobacter pylori (H pylori)-associated singular gastric polyposis; however, we present a rare and unusual case of recurrent multiple benign gastric polyposis post H pylori eradication resulting in intermittent gastric outlet obstruction. A 70-year-old independent male, Chinese in ethnicity, with a background of diabetes mellitus, hypertension, and a simple renal cyst presented with a combination of melena, anemia, and intermittent vomiting of partially digested food after meals. Initial gastroscopy was positive for H pylori; thus he was treated with H pylori eradication and proton pump inhibitors. Serial gastroscopy demonstrated multiple sessile gastric antral polyps, the largest measuring 4 cm. Histopathologic examination confirmed a benign hyperplastic lesion. Computed tomography identified a pyloric mass with absent surrounding infiltration or metastasis. A distal gastrectomy was performed, whereby multiple small pyloric polyps were found, the largest prolapsing into the pyloric opening, thus explaining the intermittent nature of gastric outlet obstruction. Such polyps often develop from gastric ulcers and, if left untreated, may undergo neoplasia to form malignant cells. A distal gastrectomy was an effective choice of treatment, taking into account the polyp size, quantity, and potential for malignancy as opposed to an endoscopic approach, which may not guarantee a complete removal of safer margins and depth. Therefore, surgical excision is favorable for multiple large gastric polyps with risk of malignancy.

  14. Characterization of Elevated Temperature Properties of Heat Exchanger and Steam Generator Alloys

    International Nuclear Information System (INIS)

    Wright, J.K.; Carroll, L.J.; Benz, J.K.; Simpson, J.A.; Wright, R.N.; Lloyd, W.R.; Chapman, J.A.

    2010-01-01

    The Next Generation Nuclear Plant project is considering Alloy 800H and Alloy 617 for steam generator and intermediate heat exchangers. It is envisioned that a steam generator would operate with reactor outlet temperatures from 750 to 800 C, while an intermediate heat exchanger for primary to secondary helium would operate up to an outlet temperature of 950 C. Although both alloys are of interest due in part to their technical maturity, a number of specific properties require further characterization for design of nuclear components. Strain rate sensitivity of both alloys has been characterized and is found to be significant above 600 C. Both alloys also exhibit dynamic strain aging, characterized by serrated flow, over a wide range of temperatures and strain rates. In general dynamic strain aging is observed to begin at higher temperatures and serrated flow persists to higher temperatures in Alloy 617 compared to Alloy 800H. Dynamic strain aging is a concern for these materials since it is observed to result in reduced ductility for many solid solution alloys. The role of dynamic strain aging in the creep-fatigue behavior of Alloy 617 at temperatures of 800 C and above has also been examined in detail. Serrated flow is found to persist in cyclic stress-strain curves up to nearly the cycle to failure in some temperature and strain regimes. Results of those experiments and implications for creep-fatigue testing protocols will be described.

  15. Pathways of warm water to the Northeast Greenland outlet glaciers

    Science.gov (United States)

    Schaffer, Janin; Timmermann, Ralph; Kanzow, Torsten; Arndt, Jan Erik; Mayer, Christoph; Schauer, Ursula

    2015-04-01

    The ocean plays an important role in modulating the mass balance of the Greenland Ice Sheet by delivering heat to the marine-terminating outlet glaciers surrounding the Greenland coast. The warming and accumulation of Atlantic Water in the subpolar North Atlantic has been suggested to be a potential driver of the glaciers' retreat over the last decades. The shelf regions thus play a critical role for the transport of Atlantic Water towards the glaciers, but also for the transfer of freshwater towards the deep ocean. A key region for the mass balance of the Greenland Ice Sheet is the Northeast Greenland Ice Stream. This large ice stream drains the second-largest basin of the Greenland Ice Sheet and feeds three outlet glaciers. The largest one is Nioghalvfjerdsfjorden (79°N-Glacier) featuring an 80 km long floating ice tongue. Both the ocean circulation on the continental shelf off Northeast Greenland and the circulation in the cavity below the ice tongue are weakly constrained so far. In order to study the relevant processes of glacier-ocean interaction we combine observations and model work. Here we focus on historic and recent hydrographic observations and on the complex bathymetry in the Northeast Greenland shelf region, which is thought to steer the flux of warm Atlantic water onto the continental shelf and into the sub-ice cavity beneath the 79°N-Glacier. We present a new global topography data set, RTopo-2, which includes the most recent surveys on the Northeast Greenland continental shelf and provides a detailed bathymetry for all around Greenland. In addition, RTopo-2 contains ice and bedrock surface topographies for Greenland and Antarctica. Based on the updated ocean bathymetry and a variety of hydrographic observations we show the water mass distribution on the continental shelf off Northeast Greenland. These maps enable us to discuss possible supply pathways of warm modified Atlantic waters on the continental shelf and thus potential ways of heat

  16. Infantile myofibromatosis: a most unusual cause of gastric outlet obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Rohrer, Kellie; Murphy, Robyn; Thresher, Caroline; Jacir, Nabil; Bergman, Kerry [Morristown Memorial Hospital, Department of Radiology, Morristown, NJ (United States)

    2005-08-01

    Non-bilious vomiting in the newborn is common. Etiologies include both surgical and medical conditions. Gastroesophageal reflux, soy or milk protein allergy, and prostaglandin-induced foveolar hyperplasia are among the medical causes. Surgical entities include gastric antral webs, pre-ampullary duodenal and pyloric atresia, and hypertrophic pyloric stenosis. We report the unique case of an 8-day-old girl who presented with gastric outlet obstruction secondary to infantile myofibromatosis. (orig.)

  17. Successful treatment with a combination of endoscopic injection and irrigation with coca cola for gastric bezoar-induced gastric outlet obstruction.

    Science.gov (United States)

    Lin, Chen-Sheng; Tung, Chun-Fang; Peng, Yen-Chun; Chow, Wei-Keung; Chang, Chi-Sen; Hu, Wei-Hsiung

    2008-01-01

    We report a case of gastric bezoar-induced gastric outlet obstruction that was successfully treated with a combination of endoscopic injection and irrigation with Coca Cola. A 73-year-old diabetic woman had a history of perforated peptic ulcer and had received pyloroplasty more than 20 years previously. She had been ingesting Pho Pu Zi (Cordia dichotoma Forst. f.) as an appetizer for 1 month. She presented with epigastric pain, nausea, and vomiting. Upper gastrointestinal endoscopy, performed at a local hospital, showed 2 gastric bezoars in the stomach, and 1 of them impacted at the pylorus. She was referred to our emergency department for removal of the gastric bezoars that were suspected to be causing gastric outlet obstruction. All attempts at endoscopic removal using a polypectomy snare, biopsy forceps and Dormia basket failed. We then injected Coca Cola directly into the bezoar mass, followed by irrigation with Coca Cola. Follow-up endoscopy was performed the next day, which revealed that the gastric bezoars had dissolved spontaneously.

  18. High Temperature Radio Frequency Loads

    CERN Document Server

    Federmann, S; Grudiev, A; Montesinos, E; Syratchev, I

    2011-01-01

    In the context of energy saving and recovery requirements the design of reliable and robust RF power loads which permit a high outlet temperature and high pressure of the cooling water is desirable. Cooling water arriving at the outlet withmore than 150 ◦C and high pressure has a higher value than water with 50 ◦C under low pressure. Conventional RF power loads containing dielectric and magnetic materials as well as sensitive ceramic windows usually do not permit going much higher than 90 ◦C. Here we present and discuss several design concepts for "metal only" RF high power loads. One concept is the application of magnetic steel corrugated waveguides near cutoff – this concept could find practical use above several GHz. Another solution are resonant structures made of steel to be installed in large waveguides for frequencies of 500 MHz or lower. Similar resonant structures above 100 MHz taking advantage of the rather high losses of normal steel may also be used in coaxial line geometries with large di...

  19. Thermotolerant Yeast Strains Adapted by Laboratory Evolution Show Trade-Off at Ancestral Temperatures and Preadaptation to Other Stresses.

    Science.gov (United States)

    Caspeta, Luis; Nielsen, Jens

    2015-07-21

    A major challenge for the production of ethanol from biomass-derived feedstocks is to develop yeasts that can sustain growth under the variety of inhibitory conditions present in the production process, e.g., high osmolality, high ethanol titers, and/or elevated temperatures (≥ 40 °C). Using adaptive laboratory evolution, we previously isolated seven Saccharomyces cerevisiae strains with improved growth at 40 °C. Here, we show that genetic adaptations to high temperature caused a growth trade-off at ancestral temperatures, reduced cellular functions, and improved tolerance of other stresses. Thermotolerant yeast strains showed horizontal displacement of their thermal reaction norms to higher temperatures. Hence, their optimal and maximum growth temperatures increased by about 3 °C, whereas they showed a growth trade-off at temperatures below 34 °C. Computational analysis of the physical properties of proteins showed that the lethal temperature for yeast is around 49 °C, as a large fraction of the yeast proteins denature above this temperature. Our analysis also indicated that the number of functions involved in controlling the growth rate decreased in the thermotolerant strains compared with the number in the ancestral strain. The latter is an advantageous attribute for acquiring thermotolerance and correlates with the reduction of yeast functions associated with loss of respiration capacity. This trait caused glycerol overproduction that was associated with the growth trade-off at ancestral temperatures. In combination with altered sterol composition of cellular membranes, glycerol overproduction was also associated with yeast osmotolerance and improved tolerance of high concentrations of glucose and ethanol. Our study shows that thermal adaptation of yeast is suitable for improving yeast resistance to inhibitory conditions found in industrial ethanol production processes. Yeast thermotolerance can significantly reduce the production costs of biomass

  20. Operation, test, research and development of the high temperature engineering test reactor (HTTR). FY1999-2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-05-01

    The HTTR (High Temperature Engineering Test Reactor) with the thermal power of 30 MW and the reactor outlet coolant temperature of 850/950 degC is the first high temperature gas-cooled reactor (HTGR) in Japan, which uses coated fuel particle, graphite for core components, and helium gas for primary coolant. The HTTR, which locates at the south-west area of 50,000 m{sup 2} in the Oarai Research Establishment, had been constructed since 1991 before accomplishing the first criticality on November 10, 1998. Rise to power tests of the HTTR started in September, 1999 and the rated thermal power of 30 MW and the reactor outlet coolant temperature of 850 degC was attained in December 2001. JAERI received the certificate of pre-operation test, that is, the commissioning license for the HTTR in March 2002. This report summarizes operation, tests, maintenance, radiation control, and construction of components and facilities for the HTTR as well as R and Ds on HTGRs from FY1999 to 2001. (author)

  1. Off-design performance of a chemical looping combustion (CLC) combined cycle: effects of ambient temperature

    Science.gov (United States)

    Chi, Jinling; Wang, Bo; Zhang, Shijie; Xiao, Yunhan

    2010-02-01

    The present work investigates the influence of ambient temperature on the steady-state off-design thermodynamic performance of a chemical looping combustion (CLC) combined cycle. A sensitivity analysis of the CLC reactor system was conducted, which shows that the parameters that influence the temperatures of the CLC reactors most are the flow rate and temperature of air entering the air reactor. For the ambient temperature variation, three off-design control strategies have been assumed and compared: 1) without any Inlet Guide Vane (IGV) control, 2) IGV control to maintain air reactor temperature and 3) IGV control to maintain constant fuel reactor temperature, aside from fuel flow rate adjusting. Results indicate that, compared with the conventional combined cycle, due to the requirement of pressure balance at outlet of the two CLC reactors, CLC combined cycle shows completely different off-design thermodynamic characteristics regardless of the control strategy adopted. For the first control strategy, temperatures of the two CLC reactors both rise obviously as ambient temperature increases. IGV control adopted by the second and the third strategy has the effect to maintain one of the two reactors' temperatures at design condition when ambient temperature is above design point. Compare with the second strategy, the third would induce more severe decrease of efficiency and output power of the CLC combined cycle.

  2. Pemilihan food outlet sebagai faktor risiko berat badan lebih anak usia sekolah dasar di Kecamatan Tegalsari Surabaya

    OpenAIRE

    Renny Evelyn Hartono; BJ. Istiti Kandarina; Siti Helmyati

    2016-01-01

    ABSTRACTIntroduction: Overweight and obesity are conditions resulting from an imbalance of calories in the body that occur in a long time and cause more deaths than underweight. One of factors related is food pattern, which also infl uenced the selection of food outlets. Surabaya is an urban area so it has many types and characteristic s of food outlet. Elementary school (4, 5, 6) do not really depend on their parents, so their food consumption and physical activity began to vary. Objectives:...

  3. Area deprivation and the food environment over time: A repeated cross-sectional study on takeaway outlet density and supermarket presence in Norfolk, UK, 1990-2008.

    Science.gov (United States)

    Maguire, Eva R; Burgoine, Thomas; Monsivais, Pablo

    2015-05-01

    Socioeconomic disparities in the food environment are known to exist but with little understanding of change over time. This study investigated the density of takeaway food outlets and presence of supermarkets in Norfolk, UK between 1990 and 2008. Data on food retail outlet locations were collected from telephone directories and aggregated within electoral wards. Supermarket presence was not associated with area deprivation over time. Takeaway food outlet density increased overall, and was significantly higher in more deprived areas at all time points; furthermore, socioeconomic disparities in takeaway food outlet density increased across the study period. These findings add to existing evidence and help assess the need for environmental interventions to reduce disparities in the prevalence of unhealthy food outlets. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. A design method to isothermalize the core of high-temperature gas-cooled reactors

    International Nuclear Information System (INIS)

    Takano, M.; Sawa, K.

    1987-01-01

    A practical design method is developed to isothermalize the core of block-type high-temperature gas-cooled reactors (HTGRs). Isothermalization plays an important role in increasing the design margin on fuel temperature. In this method, the fuel enrichment and the size and boron content of the burnable poison rod are determined over the core blockwise so that the axially exponential and radially flat power distribution are kept from the beginning to the end of core life. The method enables conventional HTGRs to raise the outlet gas temperature without increasing the maximum fuel temperature

  5. The ICS-'BPH' Study: uroflowmetry, lower urinary tract symptoms and bladder outlet obstruction

    NARCIS (Netherlands)

    Reynard, J. M.; Yang, Q.; Donovan, J. L.; Peters, T. J.; Schafer, W.; de la Rosette, J. J.; Dabhoiwala, N. F.; Osawa, D.; Lim, A. T.; Abrams, P.

    1998-01-01

    To explore the relationship between uroflow variables and lower urinary tract symptoms (LUTS): to define performance statistics (sensitivity, specificity, positive and negative predictive values) for maximum urinary flow rate (Qmax) with respect to bladder outlet obstruction (BOO) at various

  6. Complot test section outlet CFD optimization (pre - test and dimensioning)

    International Nuclear Information System (INIS)

    Profir, M. M.; Moreau, V.; Kennedy, G.

    2013-01-01

    In the framework of the FP7 MAXSIMA European project, the COMPLOT (COMPonent LOop Testing) LBE experimental facility is employed for thermal-hydraulic experiments aimed to test and qualify, among other components, a buoyancy driven safety/control rods (SR/CR) system, as key components for the safe operation of the MYRRHA reactor. This paper focuses mainly on a simplified CFD representation of the SR test section outlet in order to optimise it for the testing program. Parametric cases, associated with different positions of the SR assembly have been set up and analysed. A quasi-static analysis has been performed for each case, accounting for the LBE volume displaced by the insertion of the SR bundle, by introducing appropriately positioned additional mass sources. Velocity and pressure fields, as well as pressure drop magnitudes and mass flow rates through relevant guide tube hole outlets have been calculated and compared. The CFD analysis proved that the outer boundary of the test section does not impact the expected performance of the SR (rapid transient downward insertion). Preliminary simulations reproducing the timely repositioning of the SR/CR in COMPLOT using procedures of automatic volume mesh regeneration, consistently with the rod imposed displacement, are illustrated. (authors)

  7. A Numerical Analysis of Droplet Breakup in Asymmetric T-Junctions with Different Outlet Pressure Gradients

    Science.gov (United States)

    Cheng, Way Lee; Han, Arum; Sadr, Reza

    2016-11-01

    Droplet splitting is the breakup of a parent droplet into two or more daughter droplets of desired sizes. It is done to improve production efficiency and investigational capacity in microfluidic devices. Passive splitting is the breakup of droplets into precise volume ratios at predetermined locations without external power sources. In this study, a 3-D simulation was conducted using the Volume-of-Fluid method to analysis the breakup process of a droplet in asymmetric T-junctions with different outlet arm lengths. The arrangement allows a droplet to be split into two smaller droplets of different sizes, where the volumetric ratio of the daughter droplets depends on the length ratios of the outlet arms. The study identified different breakup regimes such as primary, transition, bubble and non-breakup under different flow conditions and channel configurations. Furthermore, a close analysis to the primary breakup regimes were done to determine the breakup mechanisms at various flow conditions. The analysis show that the breakup mechanisms in asymmetric T-junctions is different than a regular split. A pseudo-phenomenological model for the breakup criteria was presented at the end. The model was an expanded version to a theoretically derived model for the symmetric droplet breakup. The Qatar National Research Fund (a member of the Qatar Founda- tion), under Grant NPRP 5-671-2-278, supported this work.

  8. Inverse heat transfer problem in digital temperature control in plate fin and tube heat exchangers

    Science.gov (United States)

    Taler, Dawid; Sury, Adam

    2011-12-01

    The aim of the paper is a steady-state inverse heat transfer problem for plate-fin and tube heat exchangers. The objective of the process control is to adjust the number of fan revolutions per minute so that the water temperature at the heat exchanger outlet is equal to a preset value. Two control techniques were developed. The first is based on the presented mathematical model of the heat exchanger while the second is a digital proportional-integral-derivative (PID) control. The first procedure is very stable. The digital PID controller becomes unstable if the water volumetric flow rate changes significantly. The developed techniques were implemented in digital control system of the water exit temperature in a plate fin and tube heat exchanger. The measured exit temperature of the water was very close to the set value of the temperature if the first method was used. The experiments showed that the PID controller works also well but becomes frequently unstable.

  9. Analysis of optimal design of low temperature economizer

    Science.gov (United States)

    Song, J. H.; Wang, S.

    2017-11-01

    This paper has studied the Off-design characteristic of low temperature economizer system based on thermodynamics analysis. Based on the data from one 1000 MW coal-fired unit, two modes of operation are contrasted and analyzed. One is to fix exhaust gas temperature and the other one is to take into account both of the average temperature difference and the exhaust gas temperature. Meanwhile, the cause of energy saving effect change is explored. Result shows that: in mode 1, the amount of decrease in coal consumption reduces from 1.11 g/kWh (under full load) to 0.54 g/kWh (under half load), and in mode 2, when the load decreases from 90% to 50%, the decrease in coal consumption reduces from 1.29 g/kWh to 0.84 g/kWh. From the result, under high load, the energy saving effect is superior, and under lower work load, energy saving effect declines rapidly when load is reduced. When load changes, the temperature difference of heat transfer, gas flow, the flue gas heat rejection and the waste heat recovery change. The energy saving effect corresponding changes result in that the energy saving effect under high load is superior and more stable. However, rational adjustment to the temperature of outlet gas can alleviate the decline of the energy saving effect under low load. The result provides theoretical analysis data for the optimal design and operation of low temperature economizer system of power plant.

  10. Operating experiences since rise-to-power test in high temperature engineering test reactor (HTTR)

    International Nuclear Information System (INIS)

    Tochio, Daisuke; Watanabe, Shuji; Motegi, Toshihiro; Kawano, Shuichi; Kameyama, Yasuhiko; Sekita, Kenji; Kawasaki, Kozo

    2007-03-01

    The rise-to-power test of the High Temperature Engineering Test Reactor (HTTR) was actually started in April 2000. The rated thermal power of 30MW and the rated reactor outlet coolant temperature of 850degC were achieved in the middle of Dec. 2001. After that, the reactor thermal power of 30MW and the reactor outlet coolant temperature of 950degC were achieved in the final rise-to-power test in April 2004. After receiving the operation licensing at 850degC, the safety demonstration tests have conducted to demonstrate inherent safety features of the HTGRs as well as to obtain the core and plant transient data for validation of safety analysis codes and for establishment of safety design and evaluation technologies. This paper summarizes the HTTR operating experiences for six years from start of the rise-to-power test that are categorized into (1) Operating experiences related to advanced gas-cooled reactor design, (2) Operating experiences for improvement of the performance, (3) Operating experiences due to fail of system and components. (author)

  11. Monitoring system for accuracy and reliability characteristics of standard temperature measurements in WWER-440 reactors

    International Nuclear Information System (INIS)

    Stanc, S.; Repa, M.

    2001-01-01

    Description of a monitoring system for accuracy and reliability characteristics of standard temperature measurements in WWER-440 reactors and benefits obtained from its use are shown in the presentation. As standard reactor temperature measurement, coolant temperature measurement at fuel assembly outlets and in loops, entered into the In-Reactor Control System , are considered. Such systems have been implemented at two V-230 reactors and are under implementation at other four V-213 reactors. (Authors)

  12. Area deprivation and the food environment over time: A repeated cross-sectional study on takeaway outlet density and supermarket presence in Norfolk, UK, 1990–2008

    Science.gov (United States)

    Maguire, Eva R.; Burgoine, Thomas; Monsivais, Pablo

    2015-01-01

    Socioeconomic disparities in the food environment are known to exist but with little understanding of change over time. This study investigated the density of takeaway food outlets and presence of supermarkets in Norfolk, UK between 1990 and 2008. Data on food retail outlet locations were collected from telephone directories and aggregated within electoral wards. Supermarket presence was not associated with area deprivation over time. Takeaway food outlet density increased overall, and was significantly higher in more deprived areas at all time points; furthermore, socioeconomic disparities in takeaway food outlet density increased across the study period. These findings add to existing evidence and help assess the need for environmental interventions to reduce disparities in the prevalence of unhealthy food outlets. PMID:25841285

  13. Flow visualization study of two-phase flow in the horizontal annulus of the fuel-channel outlet end-fitting of a CANDU reactor

    International Nuclear Information System (INIS)

    Supa-Amornkul, S.; Steward, F.R.; Lister, D.H.

    2005-01-01

    In CANDU-6 reactors, the pressurized hightemperature coolant flows through 380 fuel channels passing horizontally through the core. In 1996, higher than expected rates of wall thinning of the outlet feeders were ascribed to flow-accelerated corrosion (FAC). Such corrosion is strongly influenced by the hydrodynamics of the coolant. Results of preliminary flow visualization and modelling studies have suggested that flow conditions in the end-fitting annulus upstream of the outlet feeder may influence the pattern of FAC. For a full-scale flow visualization, an acrylic test section was built to simulate the cylindrical end-fitting with its annulus flow path. The tests were performed with water and air at atmospheric pressure and room temperature. The phase distribution along the length of the annulus was recorded with a digital video recorder. Size, concentration and velocity of the air bubbles at particular locations were studied with a high-speed digital still camera and a high-speed digital video camera. Phase distributions and variations in bubble size with velocity were determined. Significant effects on the flow patterns of spacer buttons in the annulus were observed. A commercial computational fluid dynamics (CFD) code-Fluent 6.1-was used to model the results. (authors)

  14. Tobacco retail outlet advertising practices and proximity to schools, parks and public housing affect Synar underage sales violations in Washington, DC.

    Science.gov (United States)

    Kirchner, Thomas R; Villanti, Andrea C; Cantrell, Jennifer; Anesetti-Rothermel, Andrew; Ganz, Ollie; Conway, Kevin P; Vallone, Donna M; Abrams, David B

    2015-03-01

    To examine the cross-sectional association between illicit sales of tobacco to minors, Washington DC tobacco outlet advertising practices, retail store type, the demographic make-up of the area surrounding each outlet, and the proximity of each outlet to high schools, recreational parks and public housing. Seven hundred and fifty tobacco outlets in the DC area, n=347 of which were randomly selected for inspection by the Synar Inspection Program in 2009-2010. The presence of tobacco advertisements on the interior and exterior of each outlet, and illicit tobacco sales to Synar Inspection Program youth volunteers. The presence of tobacco advertisements on the exterior of gas stations was much greater than on other retail store types (OR=6.68; 95% CI 4.05 to 11.01), as was the absence of any advertisements at bars or restaurants that sold tobacco (OR=0.33; 95% CI 0.22 to 0.52). Exterior tobacco advertisements were also more likely in predominantly African-American areas of the city (OR=3.11; 95% CI 2.28 to 4.25), and particularly likely on storefronts located closer to parks (OR=1.87; 95% CI 1.06 to 3.28). Illicit sales to minors were more common at gas stations (OR=3.01; 95% CI 1.5 to 6.3), outlets that displayed exterior tobacco advertisements closer to parks (OR=3.36; 95% CI 1.38 to 8.21), and outlets located closer to high schools in majority African-American block groups (OR=1.29; 95% CI 1.07 to 1.58). Findings demonstrate that while illicit tobacco sales to minors are occurring at acceptably low rates by Synar standards, illicit sales vary considerably by retail store type, advertising approach and proximity to high schools, parks and African-American residential areas. Future work may help inform regulatory efforts to reduce youth access at the neighbourhood, city, state and national levels. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. The influence of river water temperature annual variation to the moderator heat exchangers heat flux

    International Nuclear Information System (INIS)

    Nita, I. P.

    2015-01-01

    The Main Moderator heat exchangers are the most important consumers supplied by Recirculated Cooling Water (RCW) System. In order to determine an appropriate operating configuration of the RCW system it is needed to determine the flowrate required by the Main Moderator consumers, in real time. From operating experience, the required RCW flowrate necessary to be supplied to the main moderator heat exchangers is much lower than design flowrate. In installation, there are no flow elements that could measure especially that flow. However, there are two control valves which regulate the flow to the main moderator heaters; they control the outlet temperature of the moderator to 69"oC. That leads to the requirement of calculating the flowrate function of the outside temperature for all possible temperatures during a calendar year. One considered all possible temperatures during an operating year, and more, going beyond design point, up to 36"oC, temperature that can occur during quick transients after forth RCW pump starting. The calculation was made to verify the capacity of heat exchanger to remove the designed 100 MW(t) in the new condition of reducing moderator temperature outlet from 77 to 69°C. The obtained model was validated using field temperatures and flow measurements and the conclusion was the model can accurately predict how the RCW system operates in all year operation conditions. (authors)

  16. Experiences with high temperature corrosion at straw‐firing power plants in Denmark

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Jensen, S. A.; Borg, U.

    2011-01-01

    to enable better lifetime prediction of vulnerable components in straw‐firing plants since the corrosion rates are so much faster than in coal firing plants. Therefore, there are continued investigations in recently commissioned plants with test tubes installed into actual superheaters. In addition...... temperature is measured on the specific tube loops where there are test tube sections. Thus a corrosion rate can be coupled to a temperature histogram. This is important since although a superheater has a defined steam outlet temperature, there is variation in the tube bundle due to variations of heat flux...

  17. Association between Childhood Obesity and Neighbourhood Accessibility to Fast-Food Outlets: A Nationwide 6-Year Follow-Up Study of 944,487 Children.

    Science.gov (United States)

    Hamano, Tsuyoshi; Li, Xinjun; Sundquist, Jan; Sundquist, Kristina

    2017-01-01

    The aim of this 6-year follow-up study was to examine whether neighbourhood accessibility to fast-food outlets was associated with diagnosed childhood obesity, after adjustment for neighbourhood- and individual-level socio-demographic factors. This 6-year follow-up study comprised 484,677 boys and 459,810 girls aged 0-14 years in Sweden. The follow-up period ran from January 1, 2005, until hospitalisation/out-patient treatment for obesity, death, emigration or the end of the study period on December 31, 2010. Multilevel logistic regression models (individual-level factors at the first level and neighbourhood-level factors at the second level) were used to calculate odds ratios (ORs) with 95% confidence intervals (95% CIs). We identified 6,968 obesity cases (3,878 boys and 3,090 girls) during the follow-up period. Higher odds of childhood obesity for those living in neighbourhoods with accessibility to fast-food outlets was observed (OR = 1.14, 95% CI = 1.07-1.22) that remained significant after adjustments (OR = 1.06, 95% CI = 1.00-1.13). This prospective nationwide study showed that the neighbourhood accessibility to fast-food outlets was independently associated with increased odds of diagnosed childhood obesity. This finding implicates that residential environments should be considered when developing health promotion programmes. © 2017 The Author(s) Published by S. Karger GmbH, Freiburg.

  18. Primary system temperature limits and transient mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Drucker, G.S.; Bost, D.S.

    1978-10-03

    Results of a study to determine the limiting temperature conditions in a large reactor system are presented. The study considers a sodium-cooled breeder reactor system having a loop-type primary system configuration. A temperature range of 930 to 1050/sup 0/F in reactor outlet temperature is covered. Significant findings were that the use of the materials for the 930/sup 0/F reference design, i.e., a core material of 20% cold-worked 316 stainless steel, a primary piping material of 316SS, and a steam generator material of unstabilized 2-1/4 Cr - 1 Mo resulted in limiting conditions in component performance at the higher temperatures. Means to circumvent these limits through the use of alternate materials, mitigation of thermal transients, and/or design changes are presented. The economic incentive to make some materials changes is also presented.

  19. Experimental Investigation of a Mechanical Vapour Compression Chiller at Elevated Chilled Water Temperatures

    KAUST Repository

    Thu, Kyaw; Saththasivam, Jayaprakash; Saha, Bidyut Baran; Chua, Kian Jon; Srinivasa Murthy, S.; Ng, Kim Choon

    2017-01-01

    The performance of a Mechanical Vapour Compression (MVC) chiller is experimentally investigated under operating conditions suitable for sensible cooling. With the emergence of the energy efficient dehumidification systems, it is possible to decouple the latent load from the MVC chillers which can be operated at higher chilled water temperature for handling sensible cooling load. In this article, the performance of the chiller is evaluated at the elevated chilled water outlet temperatures (7 – 17° C) at various coolant temperatures (28 – 32° C) and flow rates (ΔT = 4 and 5° C) for both full- and part-load conditions. Keeping the performance at the AHRI standard as the baseline condition, the efficacy of the chiller in terms of compression ratio, cooling capacity and COP at aforementioned conditions is quantified experimentally. It is observed that for each one-degree Celsius increase in the chilled water temperature, the COP of the chiller improves by about 3.5% whilst the cooling capacity improvement is about 4%. For operation at 17° C chilled water outlet temperature, the improvements in COP and cooling capacity are between 37 – 40% and 40 – 45%, respectively, compared to the performance at the AHRI standards. The performance of the MVC chiller at the abovementioned operation conditions is mapped on the chiller performance characteristic chart.

  20. Experimental Investigation of a Mechanical Vapour Compression Chiller at Elevated Chilled Water Temperatures

    KAUST Repository

    Thu, Kyaw

    2017-05-18

    The performance of a Mechanical Vapour Compression (MVC) chiller is experimentally investigated under operating conditions suitable for sensible cooling. With the emergence of the energy efficient dehumidification systems, it is possible to decouple the latent load from the MVC chillers which can be operated at higher chilled water temperature for handling sensible cooling load. In this article, the performance of the chiller is evaluated at the elevated chilled water outlet temperatures (7 – 17° C) at various coolant temperatures (28 – 32° C) and flow rates (ΔT = 4 and 5° C) for both full- and part-load conditions. Keeping the performance at the AHRI standard as the baseline condition, the efficacy of the chiller in terms of compression ratio, cooling capacity and COP at aforementioned conditions is quantified experimentally. It is observed that for each one-degree Celsius increase in the chilled water temperature, the COP of the chiller improves by about 3.5% whilst the cooling capacity improvement is about 4%. For operation at 17° C chilled water outlet temperature, the improvements in COP and cooling capacity are between 37 – 40% and 40 – 45%, respectively, compared to the performance at the AHRI standards. The performance of the MVC chiller at the abovementioned operation conditions is mapped on the chiller performance characteristic chart.

  1. Numerical Research on Hydraulically Generated Vibration and Noise of a Centrifugal Pump Volute with Impeller Outlet Width Variation

    Directory of Open Access Journals (Sweden)

    Houlin Liu

    2014-01-01

    Full Text Available The impeller outlet width of centrifugal pumps is of significant importance for numbers of effects. In the paper, these effects including the performance, pressure pulsations, hydraulically generated vibration, and noise level are investigated. For the purpose, two approaches were used to predict the vibration and sound radiation of the volute under fluid excitation force. One approach is the combined CFD/FEM analysis for structure vibration, and then the structure response obtained from the FEM analysis is treated as the boundary condition for BEM analysis for sound radiation. The other is the combined CFD/FEM/BEM coupling method. Before the numerical methods were used, the simulation results were validated by the vibration acceleration of the monitoring points on the volute. The vibration and noise were analyzed and compared at three flow conditions. The analysis of the results shows that the influences of the sound pressure of centrifugal pumps on the structure appear insignificant. The relative outlet width b2* at nq(SI = 26.7 in this paper should be less than 0.06, based on an overall consideration of the pump characteristics, pressure pulsations, vibration and noise level.

  2. 3D Printing in Surgical Management of Double Outlet Right Ventricle.

    Science.gov (United States)

    Yoo, Shi-Joon; van Arsdell, Glen S

    2017-01-01

    Double outlet right ventricle (DORV) is a heterogeneous group of congenital heart diseases that require individualized surgical approach based on precise understanding of the complex cardiovascular anatomy. Physical 3-dimensional (3D) print models not only allow fast and unequivocal perception of the complex anatomy but also eliminate misunderstanding or miscommunication among imagers and surgeons. Except for those cases showing well-recognized classic surgical anatomy of DORV such as in cases with a typical subaortic or subpulmonary ventricular septal defect, 3D print models are of enormous value in surgical decision and planning. Furthermore, 3D print models can also be used for rehearsal of the intended procedure before the actual surgery on the patient so that the outcome of the procedure is precisely predicted and the procedure can be optimally tailored for the patient's specific anatomy. 3D print models are invaluable resource for hands-on surgical training of congenital heart surgeons.

  3. 3D Printing in Surgical Management of Double Outlet Right Ventricle

    Directory of Open Access Journals (Sweden)

    Shi-Joon Yoo

    2018-01-01

    Full Text Available Double outlet right ventricle (DORV is a heterogeneous group of congenital heart diseases that require individualized surgical approach based on precise understanding of the complex cardiovascular anatomy. Physical 3-dimensional (3D print models not only allow fast and unequivocal perception of the complex anatomy but also eliminate misunderstanding or miscommunication among imagers and surgeons. Except for those cases showing well-recognized classic surgical anatomy of DORV such as in cases with a typical subaortic or subpulmonary ventricular septal defect, 3D print models are of enormous value in surgical decision and planning. Furthermore, 3D print models can also be used for rehearsal of the intended procedure before the actual surgery on the patient so that the outcome of the procedure is precisely predicted and the procedure can be optimally tailored for the patient’s specific anatomy. 3D print models are invaluable resource for hands-on surgical training of congenital heart surgeons.

  4. Tobacco outlet density and converted versus native non-daily cigarette use in a national US sample.

    Science.gov (United States)

    Kirchner, Thomas R; Anesetti-Rothermel, Andrew; Bennett, Morgane; Gao, Hong; Carlos, Heather; Scheuermann, Taneisha S; Reitzel, Lorraine R; Ahluwalia, Jasjit S

    2017-01-01

    Investigate whether non-daily smokers' (NDS) cigarette price and purchase preferences, recent cessation attempts, and current intentions to quit are associated with the density of the retail cigarette product landscape surrounding their residential address. Cross-sectional assessment of N=904 converted NDS (CNDS). who previously smoked every day, and N=297 native NDS (NNDS) who only smoked non-daily, drawn from a national panel. Kernel density estimation was used to generate a nationwide probability surface of tobacco outlets linked to participants' residential ZIP code. Hierarchically nested log-linear models were compared to evaluate associations between outlet density, non-daily use patterns, price sensitivity and quit intentions. Overall, NDS in ZIP codes with greater outlet density were less likely than NDS in ZIP codes with lower outlet density to hold 6-month quit intentions when they also reported that price affected use patterns (G 2 =66.1, ppurchase locations (G 2 =85.2, pprice influenced the amount they smoke (G 2 =43.9, pprices (G 2 =59.3, pprice affected their cigarette brand choice compared with those in ZIP codes with lower density. This paper provides initial evidence that the point-of-sale cigarette environment may be differentially associated with the maintenance of CNDS versus NNDS patterns. Future research should investigate how tobacco control efforts can be optimised to both promote cessation and curb the rising tide of non-daily smoking in the USA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Experimental study on the safety of Kyoto University Research Reactor at natural circulation cooling mode

    International Nuclear Information System (INIS)

    Zhang, Jian; Shen, Xiuzhong; Fujihara, Yasuyuki; Sano, Tadafumi; Yamamoto, Toshihiro; Nakajima, Ken

    2015-01-01

    Highlights: • The natural circulation cooling capacity of Kyoto University Research Reactor (KUR) was experimentally investigated. • The distributions of the outlet temperature of the fuel elements under natural circulation operations were measured. • The average temperature rise and the average natural circulation flow velocity in core were calculated. • The safety of KUR under all of the normal operations with natural circulation cooling mode has been analyzed. • The natural circulation flow after the reactor shutdown was confirmed. - Abstract: In this study, the natural circulation cooling capacity of Kyoto University Research Reactor (KUR) is experimentally investigated by measuring the inlet and outlet temperatures of the core under natural circulation operation at various thermal powers ranging from 10 kW to 100 kW and the shutdown state. In view of the uneven power distribution and the resultant inconsistent coolant outlet temperature in the core, eight measuring points located separately in the outlet of the fuel elements were chosen to investigate the distribution of the outlet temperature of the core. The natural circulation cooling capacity represented by the average natural circulation flow velocity in the core is calculated from the temperature difference between the outlet and inlet temperature of the core. The measured outlet temperature of the fuel elements shows a cross-sectional distribution agreeing with the distribution of the thermal output of the fuel elements in the core. Since the measured outlet temperatures decrease quickly in the flow direction in a small local region above the outlet of the core, the mixing of the hot water out of the core with the cold water around the core outlet is found to happen in the small region not more than 5 cm far from the core outlet. The natural circulation flow velocity in the core increases non-linearly with the thermal power. The safety of KUR has been analysed by conservatively estimating the

  6. Does availability of physical activity and food outlets differ by race and income? Findings from an enumeration study in a health disparate region.

    Science.gov (United States)

    Hill, Jennie L; Chau, Clarice; Luebbering, Candice R; Kolivras, Korine K; Zoellner, Jamie

    2012-09-06

    Low-income, ethnic/racial minorities and rural populations are at increased risk for obesity and related chronic health conditions when compared to white, urban and higher-socio-economic status (SES) peers. Recent systematic reviews highlight the influence of the built environment on obesity, yet very few of these studies consider rural areas or populations. Utilizing a CBPR process, this study advances community-driven causal models to address obesity by exploring the difference in resources for physical activity and food outlets by block group race and income in a small regional city that anchors a rural health disparate region. To guide this inquiry we hypothesized that lower income and racially diverse block groups would have fewer food outlets, including fewer grocery stores and fewer physical activity outlets. We further hypothesized that walkability, as defined by a computed walkability index, would be lower in the lower income block groups. Using census data and GIS, base maps of the region were created and block groups categorized by income and race. All food outlets and physical activity resources were enumerated and geocoded and a walkability index computed. Analyses included one-way MANOVA and spatial autocorrelation. In total, 49 stores, 160 restaurants and 79 physical activity outlets were enumerated. There were no differences in the number of outlets by block group income or race. Further, spatial analyses suggest that the distribution of outlets is dispersed across all block groups. Under the larger CPBR process, this enumeration study advances the causal models set forth by the community members to address obesity by providing an overview of the food and physical activity environment in this region. This data reflects the food and physical activity resources available to residents in the region and will aid many of the community-academic partners as they pursue intervention strategies targeting obesity.

  7. Does availability of physical activity and food outlets differ by race and income? Findings from an enumeration study in a health disparate region

    Directory of Open Access Journals (Sweden)

    Hill Jennie L

    2012-09-01

    Full Text Available Abstract Background Low-income, ethnic/racial minorities and rural populations are at increased risk for obesity and related chronic health conditions when compared to white, urban and higher-socio-economic status (SES peers. Recent systematic reviews highlight the influence of the built environment on obesity, yet very few of these studies consider rural areas or populations. Utilizing a CBPR process, this study advances community-driven causal models to address obesity by exploring the difference in resources for physical activity and food outlets by block group race and income in a small regional city that anchors a rural health disparate region. To guide this inquiry we hypothesized that lower income and racially diverse block groups would have fewer food outlets, including fewer grocery stores and fewer physical activity outlets. We further hypothesized that walkability, as defined by a computed walkability index, would be lower in the lower income block groups. Methods Using census data and GIS, base maps of the region were created and block groups categorized by income and race. All food outlets and physical activity resources were enumerated and geocoded and a walkability index computed. Analyses included one-way MANOVA and spatial autocorrelation. Results In total, 49 stores, 160 restaurants and 79 physical activity outlets were enumerated. There were no differences in the number of outlets by block group income or race. Further, spatial analyses suggest that the distribution of outlets is dispersed across all block groups. Conclusions Under the larger CPBR process, this enumeration study advances the causal models set forth by the community members to address obesity by providing an overview of the food and physical activity environment in this region. This data reflects the food and physical activity resources available to residents in the region and will aid many of the community-academic partners as they pursue intervention

  8. Personal values, marketing attitudes and nutrition trust are associated with patronage of convenience food outlets in the Asia-Pacific region: a cross-sectional study.

    Science.gov (United States)

    De Jong, Breanna; Worsley, Anthony; Wang, Wei Chun; Sarmugam, Rani; Pham, Quynh; Februhartanty, Judhiastuty; Ridley, Stacey

    2017-02-16

    An online cross-sectional survey examined the relationships between the demographic characteristics, personal values, trust in sources of nutrition information and the use of convenience food outlets among middle-class household food providers in the Asia-Pacific region. The survey was administered to 3945 household food providers in Melbourne, Singapore, Shanghai, Vietnam and Indonesia in late 2013. Information about demographics, personal values, trust in sources of nutrition information and use of convenience food outlets was elicited. Exploratory factor analysis, two-step clustering and logistic regression were employed. The analyses found that the use of convenience food outlets was positively related to hedonist values and trust in food industry sources of nutrition information. However, lesser use of convenience food outlets and trust in health sources of nutrition information was associated with traditional (community-oriented) values. Further replication and extension of these findings would be useful. However, they suggest that improvements in the quality of foods sold in convenience food outlets combined with stronger regulation of food marketing and long-term food education are required.

  9. Effect of short-term outlet obstruction on rat bladder nerve density and contractility

    NARCIS (Netherlands)

    Barendrecht, M. M.; Chichester, P.; Michel, M. C.; Levin, R. M.

    2007-01-01

    1 The present study was designed to investigate the relationship between innervation density and contractile responses to field stimulation and exogenous agonists at early time points after induction of bladder outlet obstruction (BOO) in rats. 2 When compared with sham-operated animals, 1, 3 and 7

  10. Thermotolerant Yeast Strains Adapted by Laboratory Evolution Show Trade-Off at Ancestral Temperatures and Preadaptation to Other Stresses

    DEFF Research Database (Denmark)

    Caspeta, Luis; Nielsen, Jens

    2015-01-01

    adaptive laboratory evolution, we previously isolated seven Saccharomyces cerevisiae strains with improved growth at 40°C. Here, we show that genetic adaptations to high temperature caused a growth trade-off at ancestral temperatures, reduced cellular functions, and improved tolerance of other stresses...... in the ancestral strain. The latter is an advantageous attribute for acquiring thermotolerance and correlates with the reduction of yeast functions associated with loss of respiration capacity. This trait caused glycerol overproduction that was associated with the growth trade-off at ancestral temperatures....... In combination with altered sterol composition of cellular membranes, glycerol overproduction was also associated with yeast osmotolerance and improved tolerance of high concentrations of glucose and ethanol. Our study shows that thermal adaptation of yeast is suitable for improving yeast resistance...

  11. Occurrence and seasonal variations of per- and polyfluoroalkyl substances (PFASs) including fluorinated alternatives in rivers, drain outlets and the receiving Bohai Sea of China.

    Science.gov (United States)

    Chen, Hong; Han, Jianbo; Zhang, Can; Cheng, Jiayi; Sun, Ruijun; Wang, Xiaomeng; Han, Gengchen; Yang, Wenchao; He, Xin

    2017-12-01

    A simultaneous sampling campaign was undertaken to study the pollution by 21 per- and polyfluoroalkyl substances (PFASs) in rivers, drain outlets and their receiving Bohai Sea of China. Chlorinated polyfluoroalkyl ether sulfonic acids (Cl-PFESAs) are being used as fluorinated alternatives and they were included in this study. In comparison with other regions and countries, high concentrations of ∑ 21 PFASs in seawater samples from the Bohai Sea, ranging from 5.03 to 41 700 ng/L (median: 64.8 ng/L), were observed. The spatial distribution of PFAS levels in this sea area was in the ranking of Laizhou Bay > Liaodong Bay > Bohai Bay > other sea areas. By comparing the levels and composition profiles of PFASs in the seawater and their sources (rivers and drain outlets), it was concluded that rivers and drain outlets are the primary sources of PFAS contamination to the Bohai Sea. These PFAS levels varied seasonally among the rivers and drain outlets, but statistically significant changes were not observed. Levels of 6:2 and 8:2 Cl-PFESAs in rivers, drain outlets and receiving sea were firstly reported in the present study. Relatively high concentrations of 6:2 Cl-PFESA were found in drain outlets, ranging from below method limits of quantification (MLQ) to 7600 ng/L, but 8:2 Cl-PFAES detection was infrequent and all median concentration below MLQ. Mass discharges to the sea of 6:2 Cl-PFESA from rivers and drain outlets to the sea were estimated to be 37 and 17 kg/y, respectively. Copyright © 2017. Published by Elsevier Ltd.

  12. Successful Treatment with a Combination of Endoscopic Injection and Irrigation with Coca Cola for Gastric Bezoar-induced Gastric Outlet Obstruction

    Directory of Open Access Journals (Sweden)

    Chen-Sheng Lin

    2008-01-01

    Full Text Available We report a case of gastric bezoar-induced gastric outlet obstruction that was successfully treated with a combination of endoscopic injection and irrigation with Coca Cola. A 73-year-old diabetic woman had a history of perforated peptic ulcer and had received pyloroplasty more than 20 years previously. She had been ingesting Pho Pu Zi (Cordia dichotoma Forst. f. as an appetizer for 1 month. She presented with epigastric pain, nausea, and vomiting. Upper gastrointestinal endoscopy, performed at a local hospital, showed 2 gastric bezoars in the stomach, and 1 of them impacted at the pylorus. She was referred to our emergency department for removal of the gastric bezoars that were suspected to be causing gastric outlet obstruction. All attempts at endoscopic removal using a polypectomy snare, biopsy forceps and Dormia basket failed. We then injected Coca Cola directly into the bezoar mass, followed by irrigation with Coca Cola. Follow-up endoscopy was performed the next day, which revealed that the gastric bezoars had dissolved spontaneously.

  13. CFD analysis of moderator flow and temperature fields inside a vertical calandria vessel of nuclear reactor

    International Nuclear Information System (INIS)

    Kansal, Anuj Kumar; Joshi, Jyeshtharaj B.; Maheshwari, Naresh Kumar; Vijayan, Pallippattu Krishnan

    2015-01-01

    Highlights: • 3D CFD of vertical calandria vessel. • Spatial distribution of volumetric heat generation. • Effect of Archimedes number. • Non-dimensional analysis. - Abstract: Three dimensional computational fluid dynamics (CFD) analysis has been performed for the moderator flow and temperature fields inside a vertical calandria vessel of nuclear reactor under normal operating condition using OpenFOAM CFD code. OpenFOAM is validated by comparing the predicted results with the experimental data available in literature. CFD model includes the calandria vessel, calandria tubes, inlet header and outlet header. Analysis has been performed for the cases of uniform and spatial distribution of volumetric heat generation. Studies show that the maximum temperature in moderator is lower in the case of spatial distribution of heat generation as compared to that in the uniform heat generation in calandria. In addition, the effect of Archimedes number on maximum and average moderator temperature was investigated

  14. CFD analysis of moderator flow and temperature fields inside a vertical calandria vessel of nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kansal, Anuj Kumar, E-mail: akansal@barc.gov.in [Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Joshi, Jyeshtharaj B., E-mail: jbjoshi@gmail.com [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India); Maheshwari, Naresh Kumar, E-mail: nmahesh@barc.gov.in [Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Vijayan, Pallippattu Krishnan, E-mail: vijayanp@barc.gov.in [Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India)

    2015-06-15

    Highlights: • 3D CFD of vertical calandria vessel. • Spatial distribution of volumetric heat generation. • Effect of Archimedes number. • Non-dimensional analysis. - Abstract: Three dimensional computational fluid dynamics (CFD) analysis has been performed for the moderator flow and temperature fields inside a vertical calandria vessel of nuclear reactor under normal operating condition using OpenFOAM CFD code. OpenFOAM is validated by comparing the predicted results with the experimental data available in literature. CFD model includes the calandria vessel, calandria tubes, inlet header and outlet header. Analysis has been performed for the cases of uniform and spatial distribution of volumetric heat generation. Studies show that the maximum temperature in moderator is lower in the case of spatial distribution of heat generation as compared to that in the uniform heat generation in calandria. In addition, the effect of Archimedes number on maximum and average moderator temperature was investigated.

  15. Survey on Cooled-Vessel Designs in High Temperature Gas-Cooled Reactors

    International Nuclear Information System (INIS)

    Kim, Min-Hwan; Lee, Won-Jae

    2006-01-01

    The core outlet temperature of the coolant in the high temperature gas-cooled reactors (HTGR) has been increased to improve the overall efficiency of their electricity generation by using the Brayton cycle or their nuclear hydrogen production by using thermo-chemical processes. The increase of the outlet temperature accompanies an increase of the coolant inlet temperature. A high coolant inlet temperature results in an increase of the reactor pressure vessel (RPV) operation temperature. The conventional steels, proven vessel material in light water reactors, cannot be used as materials for the RPV in the elevated temperatures which necessitate its design to account for the creep effects. Some ferritic or martensitic steels like 2 1/4Cr-1Mo and 9Cr-1Mo-V are very well established creep resistant materials for a temperature range of 400 to 550 C. Although these materials have been used in a chemical plant, there is limited experience with using these materials in nuclear reactors. Even though the 2 1/4Cr-1Mo steel was used to manufacture the RPV for HTR-10 of Japan Atomic Energy Agency(JAEA), a large RPV has not been manufactured by using this material or 9Cr-1Mo-V steel. Due to not only its difficulties in manufacturing but also its high cost, the JAEA determined that they would exclude these materials from the GTHTR design. For the above reasons, KAERI has been considering a cooled-vessel design as an option for the RPV design of a NHDD plant (Nuclear Hydrogen Development and Demonstration). In this study, we surveyed several HTGRs, which adopt the cooled-vessel concept for their RPV design, and discussed their design characteristics. The survey results in design considerations for the NHDD cooled-vessel design

  16. Evaluating Capability of Devils Lake Emergency Outlets in Lowering Lake Water Levels While Controlling flooding Damage to Downstream

    Science.gov (United States)

    Shabani, A.; Zhang, X.

    2017-12-01

    Devils Lake is an endorheic lake locate in the Red River of the North Basin with a natural outlet at a level of 444.7 meters above the sea level flowing into the Sheyenne River. Historical accumulation of salts has dramatically increased the concentration of salts in the lake, particularly of the sulfates, that are much greater than the surrounding water bodies. Since 1993, the lake water level has risen by nearly 10 meters and caused extensive flooding in the surrounding area, and greatly increased the chance of natural spillage to the Sheyenne River. To mitigate Devils Lake flooding and to prevent its natural spillage, two outlets were constructed at the west and east sides of the lake to drain the water to the Sheyenne River in a controlled fashion. However, pumping water from Devils Lake has degraded water quality of the Sheyenne River. In an earlier study, we coupled Soil and Water Assessment Tools (SWAT) and CE-QUAL-W2 models to investigate the changes of sulfate distribution as the lake water level rises. We found that, while operating the two outlets has lowered Devils Lake water level by 0.7 meter, it has also significantly impaired the Sheyenne River water quality, increasing the Sheyenne River average sulfate concentration from 105 to 585 mg l-1 from 2012 to 2014 In this study, we investigate the impact of the outlets on the Sheyenne River floodplain by coupling SWAT and HEC-RAS model. The SWAT model performed well in simulating daily streamflow in the Sheyenne River with R2>0.56 and ENS > 0.52. The simulated water depths and floodplain by HEC-RAS model for the Sheyenne River agreed well with observations. Operating the outlets from April to October can draw down the Devil Lake water level by 0.45 m, but the drained water would almost double the extension of the Sheyenne River floodplain and elevate the sulfate concentration in the Sheyenne River above the 450 mg l-1 North Dakota sulfate concentration standard for stream class I. Operating the outlets is

  17. Fast-food outlets and grocery stores near school and adolescents' eating habits and overweight in Finland.

    Science.gov (United States)

    Virtanen, Marianna; Kivimäki, Hanne; Ervasti, Jenni; Oksanen, Tuula; Pentti, Jaana; Kouvonen, Anne; Halonen, Jaana I; Kivimäki, Mika; Vahtera, Jussi

    2015-08-01

    Environmental factors may affect adolescents' eating habits and thereby body weight. However, the contribution of school neighbourhood environment is poorly understood. This study examined the association between proximity of a fast-food outlet or grocery store to school and adolescents' eating habits and overweight. Participants were 23 182 adolescents (mean age 15 years) who responded to a classroom survey in 181 lower secondary schools in Finland (2008-09). School location was linked to data on distance from school to the nearest fast-food outlet or grocery store (≤100 m, 101-500 m, >500 m) using global positioning system-coordinate databases. Outcomes were irregular eating habits (skipping breakfast, skipping free school lunch, skipping free school-provided snacks and not having family dinners), the accumulation of these habits and overweight, including obesity (body mass index ≥ 25 kg/m(2)). Thirteen percentage of the participants were overweight. Having a fast-food outlet or grocery store near school was associated with skipping often breakfast and free school lunch, and the accumulation of irregular eating habits. The proximity of a fast-food outlet or grocery store was associated with a 1.25-fold (95% confidence interval 1.03-1.52) risk of overweight among adolescent with a low socioeconomic status but not among those with higher socioeconomic status. This association was partly (12%) explained by the accumulation of irregular eating habits. Among adolescents from low socioeconomic background, the presence of fast-food retailers near schools is associated with accumulation of irregular eating habits and greater overweight. These findings suggest that obesogenic school neighbourhoods may contribute to social inequalities in overweight. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  18. Detention Outlet Retrofit Improves the Functionality of Existing ...

    Science.gov (United States)

    Journal Article Provide a stormwater management device for States and watershed management organizations. By discharging excess stormwater runoff at rates that more frequently exceed the critical flow for stream channel erosion, conventional detention basins often contribute to the escalated levels of instability that are common in urban and suburban streams and can be detrimental to aquatic habitat and water quality, as well as adjacent property and infrastructure. However, these ubiquitous assets, valued at ca. $600,000/km2 in a representative suburban watershed in Northern Kentucky, are ideal candidates to aid in reversing such cycles of channel degradation because improving their functionality would not necessarily require property acquisition or heavy construction. The objective of this research was to develop a simple, cost-effective device that could be installed in detention basin outlets to reduce the erosive power of the relatively frequent, but otherwise erosive, storm events (e.g. ~ ≤ 2-yr recurrence) and provide a passive bypass to maintain flood control performance during infrequent storms (e.g. 100-yr recurrence). Results from a pilot installation show that the Detain H2O device can not only meet these goals, but can also contribute to reduced flashiness and prolonged baseflows in receiving streams. When scaling the strategy across a watershed, these results suggest that substantial gains in water quality and stream channel stability could b

  19. High Temperature Gas-Cooled Reactors Lessons Learned Applicable to the Next Generation Nuclear Plant

    International Nuclear Information System (INIS)

    Beck, J.M.; Collins, J.W.; Garcia, C.B.; Pincock, L.F.

    2010-01-01

    High Temperature Gas Reactors (HTGR) have been designed and operated throughout the world over the past five decades. These seven HTGRs are varied in size, outlet temperature, primary fluid, and purpose. However, there is much the Next Generation Nuclear Plant (NGNP) has learned and can learn from these experiences. This report captures these various experiences and documents the lessons learned according to the physical NGNP hardware (i.e., systems, subsystems, and components) affected thereby.

  20. A study on the temperature distribution in the hot leg pipe

    International Nuclear Information System (INIS)

    Choe, Yoon-Jae; Baik, Se-Jin; Jang, Ho-Cheol; Lee, Byung-Jin; Im, In-Young; Ro, Tae-Sun

    2003-01-01

    In the hot leg pipes of reactor coolant system of the Korean Standard Nuclear Power Plant (KSNP), a non-uniform distribution in temperature has been observed across the cross-section, which is attributed to the non-uniformity of power distribution in the reactor core usually having a peak in the center region, and to the colder coolant bypass flow through the reactor vessel outlet nozzle clearances. As a result, the arithmetic mean temperature of four Resistance Temperature Detectors (RTDs) installed in each hot leg - two in the upper region and two in the lower region around the pipe wall may not correctly represent the actual coolant bulk temperature. It is also believed that there is a skewness in the velocity profile in the hot leg pipe due to the sudden changes in the flow direction and area from the core to the hot leg pipe, through the reactor vessel outlet plenum. These temperature non-uniformity and velocity skewness affect the measurement of the plant parameter such as the reactor coolant flow rate which is calculated by using the bulk temperature of hot leg pipes. A computational analysis has been performed to simulate the temperature and velocity distributions and to evaluate the uncertainty of temperature correction offset in the hot leg pipe. A commercial CFD code, FLUENT, is used for this analysis. The analysis results are compared with the operational data of KSNP and the scaled-down model test data for System 80. From the comparisons, an uncertainty of correction offset is obtained to measure the bulk temperature of hot leg more accurately, which can be also applied to the operating plants, leading to the reduction of temperature measurement uncertainty. Since the uncertainty of temperature in the hot leg pipe is one of major parameters to calculate the uncertainty of the reactor coolant flow rate, the analysis results can contribute to the improvement of the plant performance and safety by reducing the uncertainty of temperature measurement

  1. Design and Fabrication Technique of the Key Components for Very High Temperature Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ho Jin; Song, Ki Nam; Kim, Yong Wan

    2006-12-15

    The gas outlet temperature of Very High Temperature Reactor (VHTR) may be beyond the capability of conventional metallic materials. The requirement of the gas outlet temperature of 950 .deg. C will result in operating temperatures for metallic core components that will approach very high temperature on some cases. The materials that are capable of withstanding this temperature should be prepared, or nonmetallic materials will be required for limited components. The Ni-base alloys such as Alloy 617, Hastelloy X, XR, Incoloy 800H, and Haynes 230 are being investigated to apply them on components operated in high temperature. Currently available national and international codes and procedures are needed reviewed to design the components for HTGR/VHTR. Seven codes and procedures, including five ASME Codes and Code cases, one French code (RCC-MR), and on British Procedure (R5) were reviewed. The scope of the code and code cases needs to be expanded to include the materials with allowable temperatures of 950 .deg. C and higher. The selection of compact heat exchangers technology depends on the operating conditions such as pressure, flow rates, temperature, but also on other parameters such as fouling, corrosion, compactness, weight, maintenance and reliability. Welding, brazing, and diffusion bonding are considered proper joining processes for the heat exchanger operating in the high temperature and high pressure conditions without leakage. Because VHTRs require high temperature operations, various controlled materials, thick vessels, dissimilar metal joints, and precise controls of microstructure in weldment, the more advanced joining processes are needed than PWRs. The improved solid joining techniques are considered for the IHX fabrication. The weldability for Alloy 617 and Haynes 230 using GTAW and SMAW processes was investigated by CEA.

  2. Design and Fabrication Technique of the Key Components for Very High Temperature Reactor

    International Nuclear Information System (INIS)

    Lee, Ho Jin; Song, Ki Nam; Kim, Yong Wan

    2006-12-01

    The gas outlet temperature of Very High Temperature Reactor (VHTR) may be beyond the capability of conventional metallic materials. The requirement of the gas outlet temperature of 950 .deg. C will result in operating temperatures for metallic core components that will approach very high temperature on some cases. The materials that are capable of withstanding this temperature should be prepared, or nonmetallic materials will be required for limited components. The Ni-base alloys such as Alloy 617, Hastelloy X, XR, Incoloy 800H, and Haynes 230 are being investigated to apply them on components operated in high temperature. Currently available national and international codes and procedures are needed reviewed to design the components for HTGR/VHTR. Seven codes and procedures, including five ASME Codes and Code cases, one French code (RCC-MR), and on British Procedure (R5) were reviewed. The scope of the code and code cases needs to be expanded to include the materials with allowable temperatures of 950 .deg. C and higher. The selection of compact heat exchangers technology depends on the operating conditions such as pressure, flow rates, temperature, but also on other parameters such as fouling, corrosion, compactness, weight, maintenance and reliability. Welding, brazing, and diffusion bonding are considered proper joining processes for the heat exchanger operating in the high temperature and high pressure conditions without leakage. Because VHTRs require high temperature operations, various controlled materials, thick vessels, dissimilar metal joints, and precise controls of microstructure in weldment, the more advanced joining processes are needed than PWRs. The improved solid joining techniques are considered for the IHX fabrication. The weldability for Alloy 617 and Haynes 230 using GTAW and SMAW processes was investigated by CEA

  3. High temperature ceramic-tubed reformer

    Science.gov (United States)

    Williams, Joseph J.; Rosenberg, Robert A.; McDonough, Lane J.

    1990-03-01

    The overall objective of the HiPHES project is to develop an advanced high-pressure heat exchanger for a convective steam/methane reformer. The HiPHES steam/methane reformer is a convective, shell and tube type, catalytic reactor. The use of ceramic tubes will allow reaction temperature higher than the current state-of-the-art outlet temperatures of about 1600 F using metal tubes. Higher reaction temperatures increase feedstock conversion to synthesis gas and reduce energy requirements compared to currently available radiant-box type reformers using metal tubes. Reforming of natural gas is the principal method used to produce synthesis gas (primarily hydrogen and carbon monoxide, H2 and CO) which is used to produce hydrogen (for refinery upgrading), methanol, as well as several other important materials. The HiPHES reformer development is an extension of Stone and Webster's efforts to develop a metal-tubed convective reformer integrated with a gas turbine cycle.

  4. Quantitative detection of I-131 at the inlet and outlet of the Giessen municipality sewage works

    International Nuclear Information System (INIS)

    Leib, J.; Crecelius, R.; Pfeiff, H.; Faengewisch, G.L.

    1985-01-01

    During the sampling time, the mean quantities of the radioactive iodine delivered to the sewage works were measured to be 66 p.c. at the inlet and 28 p.c. at the outlet. Error sources of the procedure adopted for the study are assessment only of the overall inflow to the sewage treatment plant during sampling time, and lacking exactness of values for the detention period of the radioactive iodine in the sewage plant. Dispersion calculations made in addition to water examinations showed that the mean radiation dose as a result of the iodine discharges is far below the limits set by the Radiation Protection Ordinance. (orig./PW) [de

  5. Analysis of Precooling Injection Transient of Steam Generator for High Temperature Gas Cooled Reactor

    Directory of Open Access Journals (Sweden)

    Yan Wang

    2017-01-01

    Full Text Available After a postulated design basis accident leads high temperature gas cooled reactor to emergency shutdown, steam generator still remains with high temperature level and needs to be cooled down by a precooling before reactor restarts with clearing of fault. For the large difference of coolant temperature between inlet and outlet of steam generator in normal operation, the temperature distribution on the components of steam generator is very complicated. Therefore, the temperature descending rate of the components in steam generator needs to be limited to avoid the potential damage during the precooling stage. In this paper, a pebble-bed high temperature gas cooled reactor is modeled by thermal-hydraulic system analysis code and several postulated precooling injection transients are simulated and compared to evaluate their effects, which will provide support for the precooling design. The analysis results show that enough precooling injection is necessary to satisfy the precooling requirements, and larger mass flow rate of precooling water injection will accelerate the precooling process. The temperature decrease of steam generator is related to the precooling injection scenarios, and the maximal mass flow rate of the precooling injection should be limited to avoid the excessively quick temperature change of the structures in steam generator.

  6. Searching for storm water inflows in foul sewers using fibre-optic distributed temperature sensing.

    Science.gov (United States)

    Schilperoort, Rémy; Hoppe, Holger; de Haan, Cornelis; Langeveld, Jeroen

    2013-01-01

    A major drawback of separate sewer systems is the occurrence of illicit connections: unintended sewer cross-connections that connect foul water outlets from residential or industrial premises to the storm water system and/or storm water outlets to the foul sewer system. The amount of unwanted storm water in foul sewer systems can be significant, resulting in a number of detrimental effects on the performance of the wastewater system. Efficient removal of storm water inflows into foul sewers requires knowledge of the exact locations of the inflows. This paper presents the use of distributed temperature sensing (DTS) monitoring data to localize illicit storm water inflows into foul sewer systems. Data results from two monitoring campaigns in foul sewer systems in the Netherlands and Germany are presented. For both areas a number of storm water inflow locations can be derived from the data. Storm water inflow can only be detected as long as the temperature of this inflow differs from the in-sewer temperatures prior to the event. Also, the in-sewer propagation of storm and wastewater can be monitored, enabling a detailed view on advection.

  7. Comparison of fast food consumption and dietary guideline practices for children and adolescents by clustering of fast food outlets around schools in the Gyeonggi area of Korea.

    Science.gov (United States)

    Joo, Soonnam; Ju, Seyoung; Chang, Hyeja

    2015-01-01

    This study investigated the distribution density of fast food outlets around schools, and the relationship between dietary health of children and adolescents and the density of fast food outlets in Korea. A distribution map of fast food outlets was drawn by collecting information on 401 locations of 16 brands within a 15-minute walk (800 meter) of 342 elementary and secondary schools in Suwon, Hwaseong and Osan. A questionnaire was used to gather data on the dietary life of 243 sixth and eighth grade students at eight schools. Schools in the upper 20% and lower 20% of the fast food outlet distribution were classified as high-density and low-density groups, respectively. The practice rate of dietary guidelines published by the Health and Welfare Ministry and the fast food consumption pattern of children and adolescents from low and high density groups were determined. The number of schools with a fast food outlet within 200 meters or in the Green Food Zone around its location was 48 of 189 (25.4%) in Suwon and 14 of 153 (9.2%) in Hwaseong and Osan. Students in the low-density group visited fast food outlets less often than those in the high-density group (pfast food outlets within 200 meters of schools was useful for identifying the effectiveness of the Green Food Zone Act and nutrition education programs.

  8. Marketing Communications Research On Food & Beverage Outlets Of Moevenpick Hotel Saigon

    OpenAIRE

    Hoang Minh, Tam

    2012-01-01

    The purpose of this thesis was to conduct a marketing communications research on Food & Beverage Outlets of Moevenpick hotel Saigon. Besides, a short description of consumer rating on F&B service quality was other mission specifically assigned by the commissioned party. The research provided general information about both targeted potential customers from surrounding areas and current hotel guest and restaurant diner. Next was the analysis derived from the customer survey’s result, the ran...

  9. A Comparative Analysis of the Distributions of KFC and McDonald’s Outlets in China

    Directory of Open Access Journals (Sweden)

    Yikang Rui

    2016-03-01

    Full Text Available Mainland China has become one of the most important markets for international fast-food chains over the past decade. To study the regional spread of KFC and McDonald’s outlets in Chinese cities, the correlation of their distributions and degree of market expansion were explored and compared to analyze both the local and the global spatial autocorrelations. A geographically weighted Poisson regression model was also used to examine the influence of demographic, economic, and geographic factors on their spatial distributions. The findings of this comparative study reveal the site selection criteria at the city level by studying the differences and similarities in outlet distributions for KFC and McDonald’s. The presented results can guide other chains to enhance business location planning and formulate regional development policy.

  10. Lichens show that fungi can acclimate their respiration to seasonal changes in temperature.

    Science.gov (United States)

    Lange, Otto L; Green, T G Allan

    2005-01-01

    Five species of lichens, the majority members of a soil-crust community ( Cladonia convoluta, Diploschistes muscorum, Fulgensia fulgens, Lecanora muralis, Squamarina lentigera) showed seasonal changes of temperature sensitivity of their dark respiration (DR) to such an extent that several substantially met the definition of full acclimation, i.e. near identical DR under different nocturnal temperature conditions during the course of the year. C. convoluta, for example, had maximal DR at 5 degrees C of -0.42, -1.11 and -0.09 nmol CO(2) g(-1) s(-1) in autumn, winter, and summer, respectively, a tenfold range. However, at the mean night temperatures for the same three seasons, 9.7 degrees C, 4.2 degrees C and 13.6 degrees C, maximal DR were almost identical at -1.11, -0.93, and -1.45 nmol CO(2) g(-1) s(-1). The information was extracted from measurements using automatic cuvettes that continuously recorded a sample lichen's gas exchange every 30 min under near-natural conditions. The longest period (for L. muralis) covered 15 months and 22,000 data sets whilst, for the other species studied, data blocks were available throughout the calendar year. The acclimation of DR means that maximal net carbon fixation rates remain substantially similar throughout the year and are not depressed by increased carbon loss by respiration in warmer seasons. This is especially important for lichens because of their normally high rate of DR compared to net photosynthesis. We suggest that lichens, especially soil-crust species, could be a suitable model for fungi generally, a group of organisms for which little is known about temperature acclimation because of the great difficulty in separating the organism from its growth medium. Fungi, whether saprophytic, symbiotic or parasitic, including soil lichens, are important components of soil ecosystems and contribute much of the respired CO(2) from these systems. Temperature acclimation by fungi would mean that expected increases in carbon

  11. The pebble-bed high-temperature reactor as a source of nuclear process heat. Vol. 3

    International Nuclear Information System (INIS)

    Kugeler, K.; Schulten, R.; Kugeler, M.; Niessen, H.F.; Roeth-Kamat, M.; Hohn, H.; Woike, O.; Germer, J.H.

    1974-08-01

    The characteristic questions concerning a process heat reactor with high helium outlet temperatures are dealt with in this volume like e.g. fuel element design, corrosion, and fission product release. Furthermore, some possibilities of the technical realization of the hot-gas ducting and intermediate heat exchangers are described. Important parameters for the design of the reactor such as core power density, helium inlet and outlet temperatures, helium pressure and fuel cycle burn-up and conversion and the effect of these on the primary circuit are investigated. The important question regarding which reactor vessel is to be chosen for nuclear process heat plants is discussed with the aid of the integrated and non-integrated concepts using prestressed concrete, cast iron and cast steel. Thereafter, considerations on the safety of the nuclear plant are given. Finally, mention is made of the availability of the nuclear plant and of the status of development of the HTR technology. (orig.) [de

  12. Quantifying the Impacts of Outlet Control Structures on Lake Hydrology and Ecology

    Science.gov (United States)

    Budd, B. M.; Kendall, A. D.; Martin, S. L.; Hyndman, D. W.

    2012-12-01

    There have been limited studies of the impacts of lake level control structures on stream ecology and lake property erosion. We examine the influence of historical lake level management strategies on Higgins Lake in Michigan, which is regionally known for recreation, fisheries, and scenery. Lake control structures have potentially increased shoreline erosion and seasonally-reduced flow through the outlets, likely impacting fish habitat. Concerns over these issues spurred local land owners to seek a study on the possible hydrologic and ecological impacts of the removal or modification of the control structure. Bathymetry maps are fundamental to understanding and managing lake ecosystems. From the 1930's through the 1950's, these maps were developed for thousands of Michigan inland lakes using soundings lowered through holes cut in winter lake ice. Increased land use change and alterations of lake outlets have likely modified erosion and sedimentation rates of these lake systems. Our research includes bathymetry surveys of Higgins Lake using an Acoustic Doppler Current Profiler (ADCP) and side-scan sonar. The new higher-resolution bathymetry serves as the basis for simulating impacts of potential changes in lake management, on a verity of inpoint including shoreline position and fish habitat.

  13. Thermo-Acoustic Properties of a Burner with Axial Temperature Gradient: Theory and Experiment

    Directory of Open Access Journals (Sweden)

    Béla Kosztin

    2013-03-01

    Full Text Available This paper presents a model for thermo-acoustic effects in a gas turbine combustor. A quarter-wavelength burner with rectangular cross-section has been built and studied from an experimental and theoretical perspective. It has a premixed methane-air flame, which is held by a bluff body, and spans the width of the burner. The flame is compact, i.e. its length is much smaller than that of the burner. The fundamental mode of the burner is unstable; its frequency and pressure distribution have been measured. The complex pressure reflection coefficients at the upstream and downstream end of the burner were also measured. For the theoretical considerations, we divide the burner into three regions (the cold pre-combustion chamber, the flame region and the hot outlet region, and assume one-dimensional acoustic wave propagation in each region. The acoustic pressure and velocity are assumed continuous across the interface between the precombustion chamber and flame region, and across the interface between the flame region and outlet region. The burner ends are modelled by the measured pressure reflection coefficients. The mean temperature is assumed to have the following profile: uniformly cold and uniformly hot in the pre-combustion chamber and outlet region, respectively, and rising continuously from cold to hot in the flame region. For comparison, a discontinuous temperature profile, jumping directly from cold to hot, is also considered. The eigenfrequencies are calculated, and the pressure distribution of the fundamental mode is predicted. There is excellent agreement with the experimental results. The exact profile of the mean temperature in the flame region is found to be unimportant. This study gives us an experimentally validated Green's function, which is a very useful tool for further theoretical studies.

  14. Theoretical impacts of a range of major tobacco retail outlet reduction interventions: modelling results in a country with a smoke-free nation goal.

    Science.gov (United States)

    Pearson, Amber L; van der Deen, Frederieke S; Wilson, Nick; Cobiac, Linda; Blakely, Tony

    2015-03-01

    To inform endgame strategies in tobacco control, this study aimed to estimate the impact of interventions that markedly reduced availability of tobacco retail outlets. The setting was New Zealand, a developed nation where the government has a smoke-free nation goal in 2025. Various legally mandated reductions in outlets that were phased in over 10 years were modelled. Geographic analyses using the road network were used to estimate the distance and time travelled from centres of small areas to the reduced number of tobacco outlets, and from there to calculate increased travel costs for each intervention. Age-specific price elasticities of demand were used to estimate future smoking prevalence. With a law that required a 95% reduction in outlets, the cost of a pack of 20 cigarettes (including travel costs) increased by 20% in rural areas and 10% elsewhere and yielded a smoking prevalence of 9.6% by 2025 (compared with 9.9% with no intervention). The intervention that permitted tobacco sales at only 50% of liquor stores resulted in the largest cost increase (∼$60/pack in rural areas) and the lowest prevalence (9.1%) by 2025. Elimination of outlets within 2 km of schools produced a smoking prevalence of 9.3%. This modelling merges geographic, economic and epidemiological methodologies in a novel way, but the results should be interpreted cautiously and further research is desirable. Nevertheless, the results still suggest that tobacco outlet reduction interventions could modestly contribute to an endgame goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Got ACTs? Availability, price, market share and provider knowledge of anti-malarial medicines in public and private sector outlets in six malaria-endemic countries

    Directory of Open Access Journals (Sweden)

    O'Connell Kathryn A

    2011-10-01

    Full Text Available Abstract Background Artemisinin-based combination therapy (ACT is the first-line malaria treatment throughout most of the malaria-endemic world. Data on ACT availability, price and market share are needed to provide a firm evidence base from which to assess the current situation concerning quality-assured ACT supply. This paper presents supply side data from ACTwatch outlet surveys in Benin, the Democratic Republic of Congo (DRC, Madagascar, Nigeria, Uganda and Zambia. Methods Between March 2009 and June 2010, nationally representative surveys of outlets providing anti-malarials to consumers were conducted. A census of all outlets with the potential to provide anti-malarials was conducted in clusters sampled randomly. Results 28,263 outlets were censused, 51,158 anti-malarials were audited, and 9,118 providers interviewed. The proportion of public health facilities with at least one first-line quality-assured ACT in stock ranged between 43% and 85%. Among private sector outlets stocking at least one anti-malarial, non-artemisinin therapies, such as chloroquine and sulphadoxine-pyrimethamine, were widely available (> 95% of outlets as compared to first-line quality-assured ACT ( Conclusions These standardized, nationally representative results demonstrate the typically low availability, low market share and high prices of ACT, in the private sector where most anti-malarials are accessed, with some exceptions. The results confirm that there is substantial room to improve availability and affordability of ACT treatment in the surveyed countries. The data will also be useful for monitoring the impact of interventions such as the Affordable Medicines Facility for malaria.

  16. Active water exchange and life near the grounding line of an Antarctic outlet glacier

    Science.gov (United States)

    Sugiyama, Shin; Sawagaki, Takanobu; Fukuda, Takehiro; Aoki, Shigeru

    2014-08-01

    The grounding line (GL) of the Antarctic ice sheet forms the boundary between grounded and floating ice along the coast. Near this line, warm oceanic water contacts the ice shelf, producing the ice sheet's highest basal-melt rate. Despite the importance of this region, water properties and circulations near the GL are largely unexplored because in-situ observations are difficult. Here we present direct evidence of warm ocean-water transport to the innermost part of the subshelf cavity (several hundred meters seaward from the GL) of Langhovde Glacier, an outlet glacier in East Antarctica. Our measurements come from boreholes drilled through the glacier's ∼400-m-thick grounding zone. Beneath the grounding zone, we find a 10-24-m-deep water layer of uniform temperature and salinity (-1.45 °C; 34.25 PSU), values that roughly equal those measured in the ocean in front of the glacier. Moreover, living organisms are found in the thin subglacial water layer. These findings indicate active transport of water and nutrients from the adjacent ocean, meaning that the subshelf environment interacts directly and rapidly with the ocean.

  17. Evaluation of medicine retail outlets for sale of typhoid fever vaccine among adults in two urban and rural settings in western Kenya: a proof-of-concept study.

    Science.gov (United States)

    Ho, Julius; Odhiambo, Gladys; Meng'anyi, Lucy W; Musuva, Rosemary M; Mule, Joseph M; Alaly, Zakayo S; Odiere, Maurice R; Mwinzi, Pauline N; Ganley-Leal, Lisa

    2016-09-29

    Private sector medicine outlets are an important provider of health services across the developing world, and are an untapped means of distributing and selling vaccines outside of childhood immunization programs. The present study assessed the viability of medicine outlets (chemists and pharmacies) as potential channels for sale of vaccines. To evaluate the viability of the medicine outlet model, we partnered with nine outlets across urban and rural communities in western Kenya to sell a nurse-administered typhoid vaccine. Purchasers were surveyed to reveal market demographic characteristics, reasons for vaccine purchase, and sources of information about the program. Key informant interviews and focus group discussions defined acceptability, demand, and additional suggestions for improving this mechanism of selling and distributing vaccines. There was a higher than expected demand for the vaccine that resulted in stock-outs. Previous instance of typhoid, desire to prevent disease, affordable price and convenience were cited by most participants as main reasons for purchase of vaccine at the local outlet. The most common source of information on the vaccine sale was word-of-mouth and referral from friends. Longer vaccine sale duration, adequate stocking of vaccines and extended hours of administration in the evening to allow working individuals to buy vaccines were cited by participants as ways for improved participation in the future. This study demonstrated a high demand for vaccines at community medicine outlets. Important insights on how to improve and sustain such a program included extension of distribution time, education of outlet keepers, and minimizing vaccine stockouts. With improved social marketing, infrastructure mapping, education and pricing schemes, medicine outlets could become a sustainable avenue for selling adult vaccines in emerging markets for both routine and pandemic vaccines.

  18. Rise-to-power test in High Temperature Engineering Test Reactor. Test progress and summary of test results up to 30 MW of reactor thermal power

    International Nuclear Information System (INIS)

    Nakagawa, Shigeaki; Fujimoto, Nozomu; Shimakawa, Satoshi

    2002-08-01

    The High Temperature Engineering Test Reactor (HTTR) is a graphite moderated and gas cooled reactor with the thermal power of 30 MW and the reactor outlet coolant temperature of 850degC/950degC. Rise-to-power test in the HTTR was performed from April 23rd to June 6th in 2000 as phase 1 test up to 10 MW in the rated operation mode, from January 29th to March 1st in 2001 as phase 2 test up to 20 MW in the rated operation mode and from April 14th to June 8th in 2001 as phase 3 test up to 20 MW in the high temperature test the mechanism of the reactor outlet coolant temperature becomes 850degC at 30 MW in the rated operation mode and 950degC in the high temperature test operation mode. Phase 4 rise-to-power test to achieve the thermal reactor power of 30 MW started on October 23rd in 2001. On December 7th in 2001 it was confirmed that the thermal reactor power and the reactor outlet coolant temperature reached to 30 MW and 850degC respectively in the single loaded operation mode in which only the primary pressurized water cooler is operating. Phase 4 test was performed until March 6th in 2002. JAERI (Japan Atomic Energy Research Institute) obtained the certificate of the pre-operation test from MEXT (Ministry of Education Culture Sports Science and Technology) after all the pre-operation tests by MEXT were passed successfully with the reactor transient test at an abnormal event as a final pre-operation test. From the test results of the rise-up-power test up to 30 MW in the rated operation mode, performance of the reactor and cooling system were confirmed, and it was also confirmed that an operation of reactor facility can be performed safely. Some problems to be solved were found through the tests. By solving them, the reactor operation with the reactor outlet coolant temperature of 950degC will be achievable. (author)

  19. Studies on high temperature research reactor in China

    Energy Technology Data Exchange (ETDEWEB)

    Xu Yuanhui; Zuo Kanfen [Institute of Nuclear Energy Technology, Tsinghua Univ., Beijing (China)

    1999-08-01

    China recognises the advantages of Modular HTGRs and has chosen Modular HTGRs as one of advanced reactors to be developed for the further intensive utilisation of nuclear power in the next century. In energy supply systems of the next century, HTGR is supposed to serve: 1. as supplement to water-cooled reactors for electricity generation and 2. as environmentally friendly heat source providing process heat at different temperatures for various applications like heavy oil recovery, coal gasification and liquefaction, etc.. The 10 MW High Temperature Gas-cooled Reactor (HTR-10) is a major project in the energy sector of the Chinese National High Technology Programme as the first step of development of Modular HTGRs in China. Its main objectives are: 1. to acquire know-how in the design, construction and operation of HTGRs, 2. to establish an irradiation and experimental facility, 3. to demonstrate the inherent safety features of Modular HTGR, 4. to test electricity and heat co-generation and closed cycle gas turbine technology and 5. to do research and development work on the nuclear process heat application. Now the HTR-10 is being constructed at the site of Institute of Nuclear Energy Technology (INET). The HTR-10 project is to be carried out in two phases. In the first phase, the reactor with an coolant outlet temperature of 700degC will be coupled with a steam generator providing steam for a steam turbine cycle which works on an electricity and heat co-generation basis. In the second phase, the reactor coolant outlet temperature is planned to be raised to 900degC. As gas turbine cycle and a steam reformer will be coupled to the reactor in addition to the steam turbine cycle. (author)

  20. Studies on high temperature research reactor in China

    International Nuclear Information System (INIS)

    Xu Yuanhui; Zuo Kanfen

    1999-01-01

    China recognises the advantages of Modular HTGRs and has chosen Modular HTGRs as one of advanced reactors to be developed for the further intensive utilisation of nuclear power in the next century. In energy supply systems of the next century, HTGR is supposed to serve: 1. as supplement to water-cooled reactors for electricity generation and 2. as environmentally friendly heat source providing process heat at different temperatures for various applications like heavy oil recovery, coal gasification and liquefaction, etc.. The 10 MW High Temperature Gas-cooled Reactor (HTR-10) is a major project in the energy sector of the Chinese National High Technology Programme as the first step of development of Modular HTGRs in China. Its main objectives are: 1. to acquire know-how in the design, construction and operation of HTGRs, 2. to establish an irradiation and experimental facility, 3. to demonstrate the inherent safety features of Modular HTGR, 4. to test electricity and heat co-generation and closed cycle gas turbine technology and 5. to do research and development work on the nuclear process heat application. Now the HTR-10 is being constructed at the site of Institute of Nuclear Energy Technology (INET). The HTR-10 project is to be carried out in two phases. In the first phase, the reactor with an coolant outlet temperature of 700degC will be coupled with a steam generator providing steam for a steam turbine cycle which works on an electricity and heat co-generation basis. In the second phase, the reactor coolant outlet temperature is planned to be raised to 900degC. As gas turbine cycle and a steam reformer will be coupled to the reactor in addition to the steam turbine cycle. (author)

  1. Calculation of plate temperatures in a Mk 4 LEU fuel element

    International Nuclear Information System (INIS)

    Haack, K.

    1991-10-01

    A calculation method for estimating the axial temperature distributions of each tube in each of the 26 fuel elements of the DR 3 core is described and demonstrated. With input data for fuel element power, D 2 O outlet temperature and main D 2 O circulator combination, a computer code calculates all important temperatures in the fuel element. Preface to Second Edition Oct. 1991. The second edition is based on the more reliable thermophysical heavy water properties made available by the investigations of Professor J. Bukovsky. The values in the tables are replaced and a new set of fuel element temperature curves is enclosed as an example of the temperature distributions in a low enriched uranium (19,8% 235 U as U 3 Si 2 ). (author) 11 tabs., 32 ills., 9 refs

  2. What determines the profitability of a retail gasoline outlet? A study for the Competition Bureau of Canada

    International Nuclear Information System (INIS)

    Sen, A.

    2006-03-01

    An independent study was conducted to better understand the key determinants of profitability in the retail gasoline industry. The economic and financial analysis was based on pricing and other financial data collected by the Competition Bureau from representative retail outlets owned by vertically-integrated firms and independent retailers in the Greater Toronto Area and adjoining areas. This study combined economic and accounting techniques to provide an objective opinion regarding allegations of anti-competitive behaviour on the part of vertically-integrated gasoline firms. It evaluated the validity of complaints such as predatory pricing, collusion, retail price-fixing, and forcing the exit of smaller independents from the industry. This document described LECG's distinctive business model that was used to evaluate complex business and organizational behavior. It included a literature review, as well as a comparative economic and profitability analysis of retail gasoline stations. The study showed that movements in both retail and wholesale prices are largely dictated by corresponding fluctuations in crude oil prices. It also showed that there is serious doubt on the possibility of strategic behaviour by vertically-integrated refiners. It was noted that the final evaluation of station efficiency is limited because of missing data on costs incurred by site operators and revenues from ancillary services such as car wash and convenience store sales. It was concluded that the critical factor driving profitability is throughput, which impacts both revenue and average total costs. Since throughput is related to population density, local traffic and degree of local competition, the loss incurred by a specific outlet can be due to poor business strategy or circumstances rather than anti-competitive behaviour. 5 refs., 17 tabs., 21 figs

  3. Accessibility of fast food outlets is associated with fast food intake. A study in the Capital Region of Denmark

    DEFF Research Database (Denmark)

    Bernsdorf, Kamille Almer; Lau, Cathrine Juel; Andreasen, Anne Helms

    2017-01-01

    Literature suggests that people living in areas with a wealth of unhealthy fast food options may show higher levels of fast food intake. Multilevel logistic regression analyses were applied to examine the association between GIS-located fast food outlets (FFOs) and self-reported fast food intake...... density and decreased significantly with increasing distance to the nearest FFO for distances ≤ 4km. For long distances (>4km), odds increased with increasing distance, although this applied only for car owners. Results suggest that Danish health promotion strategies need to consider the contribution...

  4. Research for the influence on PRHR HX performance with different inlet temperature and flow rate

    International Nuclear Information System (INIS)

    Jia Bin; Jing Jianping; An Jieru; Bi Jinsheng; Li Yuanshan; Zhuang Shaoxin

    2014-01-01

    To study the residual heat removal capacity of PRHR HX, numerical simulation is demonstrated using FLUENT. Meanwhile to research the trends of PRHR HX residual heat removal capacity, different operating modes have been simulated with parameters deviated from design value. Finally it's found that when the coolant inlet temperature is higher than design valve the residual heat removal capacity is better and the higher the temperature is the lower the coolant outlet temperature can be obtained. And meanwhile the faster the coolant flows the better the residual heat in the core can be removed. (authors)

  5. Exceptional retreat of Novaya Zemlya's marine-terminating outlet glaciers between 2000 and 2013

    Directory of Open Access Journals (Sweden)

    J. R. Carr

    2017-09-01

    Full Text Available Novaya Zemlya (NVZ has experienced rapid ice loss and accelerated marine-terminating glacier retreat during the past 2 decades. However, it is unknown whether this retreat is exceptional longer term and/or whether it has persisted since 2010. Investigating this is vital, as dynamic thinning may contribute substantially to ice loss from NVZ, but is not currently included in sea level rise predictions. Here, we use remotely sensed data to assess controls on NVZ glacier retreat between 1973/76 and 2015. Glaciers that terminate into lakes or the ocean receded 3.5 times faster than those that terminate on land. Between 2000 and 2013, retreat rates were significantly higher on marine-terminating outlet glaciers than during the previous 27 years, and we observe widespread slowdown in retreat, and even advance, between 2013 and 2015. There were some common patterns in the timing of glacier retreat, but the magnitude varied between individual glaciers. Rapid retreat between 2000 and 2013 corresponds to a period of significantly warmer air temperatures and reduced sea ice concentrations, and to changes in the North Atlantic Oscillation (NAO and Atlantic Multidecadal Oscillation (AMO. We need to assess the impact of this accelerated retreat on dynamic ice losses from NVZ to accurately quantify its future sea level rise contribution.

  6. Air demand estimation in bottom outlets with the particle finite element method. Susqueda Dam case study

    Science.gov (United States)

    Salazar, Fernando; San-Mauro, Javier; Celigueta, Miguel Ángel; Oñate, Eugenio

    2017-07-01

    Dam bottom outlets play a vital role in dam operation and safety, as they allow controlling the water surface elevation below the spillway level. For partial openings, water flows under the gate lip at high velocity and drags the air downstream of the gate, which may cause damages due to cavitation and vibration. The convenience of installing air vents in dam bottom outlets is well known by practitioners. The design of this element depends basically on the maximum air flow through the air vent, which in turn is a function of the specific geometry and the boundary conditions. The intrinsic features of this phenomenon makes it hard to analyse either on site or in full scaled experimental facilities. As a consequence, empirical formulas are frequently employed, which offer a conservative estimate of the maximum air flow. In this work, the particle finite element method was used to model the air-water interaction in Susqueda Dam bottom outlet, with different gate openings. Specific enhancements of the formulation were developed to consider air-water interaction. The results were analysed as compared to the conventional design criteria and to information gathered on site during the gate operation tests. This analysis suggests that numerical modelling with the PFEM can be helpful for the design of this kind of hydraulic works.

  7. Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Young; Lee, Soo Teik; Yang, Doo Hyun

    2001-07-01

    AIM: To evaluate the feasibility and safety of fluoroscopic-guided covered metallic stent placements in providing palliative care for patients with inoperable malignant gastric outlet obstruction. MATERIALS AND METHODS: Under fluoroscopic guidance, placement of self-expandable, covered stents was attempted in 20 patients with inoperable or recurrent gastric cancer (age range 36-79 years). All patients had inoperable gastric outlet obstruction, 13 with native anatomy and seven with post-operative anatomy (gastrointestinal anastomotic sites). All patients had intolerance to oral alimentation and/or vomiting after ingestion. Success was defined both technically and clinically. RESULTS: The placement of the stent was technically successful in 18 patients and failed in two patients (technical success: 90%). The cause of the technical failures was an inability to negotiate the guide wire through the obstruction sites in spite of the use of both fluoroscopic and endoscopic guidance. After stent placement, 15 patients were able to ingest at least liquids and had a markedly decreased incidence of vomiting (clinical success: 75%). During the mean follow-up of 6 weeks, there have been no stent reocclusion and no life-threatening complications except migration of two stents in one patient. CONCLUSION: Fluoroscopically guided covered metallic stent placement appears to be valuable for the palliative treatment of malignant obstruction of gastric outlet and post-operative gastrointestinal anastomoses. Lee, J.M. et al. (2001)

  8. Endoscopic magnetic gastroenteric anastomosis for palliation of malignant gastric outlet obstruction: a prospective multicenter study

    NARCIS (Netherlands)

    van Hooft, Jeanin E.; Vleggaar, Frank P.; Moine, Olivier Le; Bizzotto, Alessandra; Voermans, Rogier P.; Costamagna, Guido; Devière, Jacques; Siersema, Peter D.; Fockens, Paul

    2010-01-01

    Background: Palliation of malignant gastric outlet obstruction remains challenging. Although there are 2 established treatment options, ie, surgical gastrojejunostomy and endoscopic duodenal stent insertion, there is an ongoing search for a technique that would combine the safety and rapid effect of

  9. Realistic thermal transient margin analysis of 'MONJU' based on plant performance measurements. Reactor vessel outlet nozzle and evaporator feed water inlet tube sheet of the manual reactor plant trip

    International Nuclear Information System (INIS)

    Yamada, Fumiaki; Mori, Takero

    2005-01-01

    In order to develop technologies and achieve safe and stable operation of Monju' as well as realize optimized design and construction of safe and economically competitive fast breeder reactors, the authors are evaluating design approach applied to 'Monju' based on actually measured behavioral data during plant operations. This report uses actual measured characteristic data of 'Monju' during a plant trip test obtained at a commissioning stage with up to 40% power output and introduces plant thermal hydraulic behavior analysis in a representative thermal transient event, i.e. a manual plant trip. Thermal transient driven loads incurred by the reactor vessel outlet nozzle and by the evaporator feed water inlet tube sheet were further derived by structural analyses and were compared with the previously derived values in the design stage and with the limit values. Though the reactor vessel outlet nozzle was exposed to larger temperature change in the trip test than the analytical prediction, the newly calculated mechanical load was about 50% of the previous evaluation in the design stage. Also, the newly analyzed mechanical load incurred by the evaporator feed water inlet tube sheet in this event had a large margin against the limit value of cumulative damage cycle fraction, although the observed temperature disturbance in a steam blow test was wilder than the analytical prediction. Thus we concluded that the Monju' plant has an assured safety margin against thermal transient in plant trip events. (author)

  10. Associations between Food Outlets around Schools and BMI among Primary Students in England: A Cross-Classified Multi-Level Analysis.

    Science.gov (United States)

    Williams, Julianne; Scarborough, Peter; Townsend, Nick; Matthews, Anne; Burgoine, Thomas; Mumtaz, Lorraine; Rayner, Mike

    2015-01-01

    Researchers and policy-makers are interested in the influence that food retailing around schools may have on child obesity risk. Most previous research comes from North America, uses data aggregated at the school-level and focuses on associations between fast food outlets and school obesity rates. This study examines associations between food retailing and BMI among a large sample of primary school students in Berkshire, England. By controlling for individual, school and home characteristics and stratifying results across the primary school years, we aimed to identify if the food environment around schools had an effect on BMI, independent of socio-economic variables. We measured the densities of fast food outlets and food stores found within schoolchildren's home and school environments using Geographic Information Systems (GIS) and data from local councils. We linked these data to measures from the 2010/11 National Child Measurement Programme and used a cross-classified multi-level approach to examine associations between food retailing and BMI z-scores. Analyses were stratified among Reception (aged 4-5) and Year 6 (aged 10-11) students to measure associations across the primary school years. Our multilevel model had three levels to account for individual (n = 16,956), home neighbourhood (n = 664) and school (n = 268) factors. After controlling for confounders, there were no significant associations between retailing near schools and student BMI, but significant positive associations between fast food outlets in home neighbourhood and BMI z-scores. Year 6 students living in areas with the highest density of fast food outlets had an average BMI z-score that was 0.12 (95% CI: 0.04, 0.20) higher than those living in areas with none. We found little evidence to suggest that food retailing around schools influences student BMI. There is some evidence to suggest that fast food outlet densities in a child's home neighbourhood may have an effect on BMI, particularly

  11. Associations between Food Outlets around Schools and BMI among Primary Students in England: A Cross-Classified Multi-Level Analysis.

    Directory of Open Access Journals (Sweden)

    Julianne Williams

    Full Text Available Researchers and policy-makers are interested in the influence that food retailing around schools may have on child obesity risk. Most previous research comes from North America, uses data aggregated at the school-level and focuses on associations between fast food outlets and school obesity rates. This study examines associations between food retailing and BMI among a large sample of primary school students in Berkshire, England. By controlling for individual, school and home characteristics and stratifying results across the primary school years, we aimed to identify if the food environment around schools had an effect on BMI, independent of socio-economic variables.We measured the densities of fast food outlets and food stores found within schoolchildren's home and school environments using Geographic Information Systems (GIS and data from local councils. We linked these data to measures from the 2010/11 National Child Measurement Programme and used a cross-classified multi-level approach to examine associations between food retailing and BMI z-scores. Analyses were stratified among Reception (aged 4-5 and Year 6 (aged 10-11 students to measure associations across the primary school years.Our multilevel model had three levels to account for individual (n = 16,956, home neighbourhood (n = 664 and school (n = 268 factors. After controlling for confounders, there were no significant associations between retailing near schools and student BMI, but significant positive associations between fast food outlets in home neighbourhood and BMI z-scores. Year 6 students living in areas with the highest density of fast food outlets had an average BMI z-score that was 0.12 (95% CI: 0.04, 0.20 higher than those living in areas with none.We found little evidence to suggest that food retailing around schools influences student BMI. There is some evidence to suggest that fast food outlet densities in a child's home neighbourhood may have an effect on BMI

  12. Evaluation of Partial Cut-out of Sacroiliac Screws From the Sacral Ala Slope via Pelvic Inlet and Outlet View.

    Science.gov (United States)

    Zhang, Jingwei; Hamilton, Ryan; Li, Ming; Ebraheim, Nabil A; He, Xianfeng; Liu, Jiayong; Zhu, Limei

    2015-12-01

    An anatomic and radiographic study of placement of sacroiliac screws. The aim of this study was to quantitatively assess the risk of partial cut-out of sacroiliac screws from the sacral ala slope via inlet and outlet view. The partial cut-out of sacroiliac screws from the superior surface of sacral ala can jeopardize the L5 nerve root, which is difficult to identify on the pelvic inlet and outlet views. Computed tomography images of 60 patients without pelvic ring deformity or injury were used to measure the width (on inlet view) and height (on outlet view) of the sacral ala. The angle of the sacral ala slope was measured on lateral view. According to the measured parameters, the theoretical safe trajectories of screw placement were calculated using inverse trigonometric functions. Under fluoroscopic guidance, a sacroiliac screw was placed close to the midline on both inlet and outlet views, including posterosuperior, posteroinferior, anterosuperior, and anteroinferior regions to the midline. The incidence of screw partial cut-out from the superior surface of sacral ala was identified. The measured widths and heights of the sacral alas were 28.1 ± 2.8 and 29.8 ± 3.1 mm, respectively. The average angle between the superior aspect of the S1 vertebral body and the superior aspect of the sacral ala was 37.2 ± 2.5 degrees. The rate of partial cut-out of the screws from the superior surface of sacral ala slope was 12.5% (5/40) in posterosuperior, 0% (0/40) in posteroinferior, 70% (28/40) in anterosuperior, and 20% (8/40) in anteroinferior. To avoid the risk of partial cut-out from sacroiliac screw placement, more precise description should be added to the conventional description: the sacroiliac screws should be placed at the inferior half portion on outlet view and at the posterior half portion on inlet view. 4.

  13. High temperature turbine engine structure

    Energy Technology Data Exchange (ETDEWEB)

    Carruthers, W.D.; Boyd, G.L.

    1993-07-20

    A hybrid ceramic/metallic gas turbine is described comprising; a housing defining an inlet, an outlet, and a flow path communicating the inlet with the outlet for conveying a flow of fluid through the housing, a rotor member journaled by the housing in the flow path, the rotor member including a compressor rotor portion rotatively inducting ambient air via the inlet and delivering this air pressurized to the flow path downstream of the compressor rotor, a combustor disposed in the flow path downstream of the compressor receiving the pressurized air along with a supply of fuel to maintain combustion providing a flow of high temperature pressurized combustion products in the flow path downstream thereof, the rotor member including a turbine rotor portion disposed in the flow path downstream of the combustor and rotatively expanding the combustion products toward ambient for flow from the turbine engine via the outlet, the turbine rotor portion providing shaft power driving the compressor rotor portion and an output shaft portion of the rotor member, a disk-like metallic housing portion journaling the rotor member to define a rotational axis therefore, and a disk-like annular ceramic turbine shroud member bounding the flow path downstream of the combustor and circumscribing the turbine rotor portion to define a running clearance therewith, the disk-like ceramic turbine shroud member having a reference axis coaxial with the rotational axis and being spaced axially from the metallic housing portion in mutually parallel concentric relation therewith and a plurality of spacers disposed between ceramic disk-like shroud member and the metallic disk-like housing portion and circumferentially spaced apart, each of the spacers having a first and second end portion having an end surface adjacent the shroud member and the housing portion respectively, the end surfaces having a cylindrical curvature extending transversely relative to the shroud member and the housing portion.

  14. Tobacco outlet density, retailer cigarette sales without ID checks and enforcement of underage tobacco laws: associations with youths' cigarette smoking and beliefs.

    Science.gov (United States)

    Lipperman-Kreda, Sharon; Grube, Joel W; Friend, Karen B; Mair, Christina

    2016-03-01

    To estimate the relationships of tobacco outlet density, cigarette sales without ID checks and local enforcement of underage tobacco laws with youth's life-time cigarette smoking, perceived availability of tobacco and perceived enforcement of underage tobacco laws and changes over time. The study involved: (a) three annual telephone surveys, (b) two annual purchase surveys in 2000 tobacco outlets and (c) interviews with key informants from local law enforcement agencies. Analyses were multi-level models (city, individual, time). A sample of 50 mid-sized non-contiguous cities in California, USA. A total of 1478 youths (aged 13-16 at wave 1, 52.2% male); 1061 participated in all waves. Measures at the individual level included life-time cigarette smoking, perceived availability and perceived enforcement. City-level measures included tobacco outlet density, cigarette sales without ID checks and compliance checks. Outlet density was associated positively with life-time smoking [OR = 1.12, P Sales rate without checking IDs was related to greater perceived availability (β = 0.01, P sales without ID checks and enforcement levels may influence beliefs about access to cigarettes and enforcement of underage tobacco sales laws. © 2015 Society for the Study of Addiction.

  15. Analytical approximations for thermophysical properties of supercritical nitrogen (SCN) to be used in futuristic high temperature superconducting (HTS) cables

    Energy Technology Data Exchange (ETDEWEB)

    Dondapati, Raja Sekhar, E-mail: drsekhar@ieee.org [School of Mechanical Engineering, Lovely Professional University, Phagwara, Punjab 144401 (India); Ravula, Jeswanth [School of Mechanical Engineering, Lovely Professional University, Phagwara, Punjab 144401 (India); Thadela, S. [Department of Mechanical Engineering, Andhra University, Visakhapatnam, Andhra Pradesh (India); Usurumarti, Preeti Rao [Department of Mechanical Engineering, P.V.K. Institute of Technology, Anantapur, Andhra Pradesh (India)

    2015-12-15

    Future power transmission applications demand higher efficiency due to the limited resources of energy. In order to meet such demand, a novel method of transmission is being developed using High Temperature Superconducting (HTS) cables. However, these HTS cables need to be cooled below the critical temperature of superconductors used in constructing the cable to retain the superconductivity. With the advent of new superconductors whose critical temperatures having reached up to 134 K (Hg based), a need arises to find a suitable coolant which can accommodate the heating loads on the superconductors. The present work proposes, Supercritical Nitrogen (SCN) to be a feasible coolant to achieve the required cooling. Further, the feasibility of proposed coolant to be used in futuristic HTS cables is investigated by studying the thermophysical properties such as density, viscosity, specific heat and thermal conductivity with respect to temperature (T{sub C} + 10 K) and pressure (P{sub C} + 10 bar). In addition, few temperature dependent analytical functions are developed for thermophysical properties of SCN which are useful in predicting thermohydraulic performance (pressure drop, pumping power and cooling capacity) using numerical or computational techniques. Also, the developed analytical functions are used to calculate the pumping power and the temperature difference between inlet and outlet of HTS cable. These results are compared with those of liquid nitrogen (LN2) and found that the circulating pumping power required to pump SCN is significantly smaller than that to pump LN2. Further, it is found that the temperature difference between the inlet and outlet is smaller as compared to that when LN2 is used, SCN can be preferred to cool long length Hg based HTS cables. - Highlights: • Analytical functions are developed for thermophysical properties of Supercritical Nitrogen. • Error analysis shows extremely low errors in the developed analytical functions.

  16. Analytical approximations for thermophysical properties of supercritical nitrogen (SCN) to be used in futuristic high temperature superconducting (HTS) cables

    International Nuclear Information System (INIS)

    Dondapati, Raja Sekhar; Ravula, Jeswanth; Thadela, S.; Usurumarti, Preeti Rao

    2015-01-01

    Future power transmission applications demand higher efficiency due to the limited resources of energy. In order to meet such demand, a novel method of transmission is being developed using High Temperature Superconducting (HTS) cables. However, these HTS cables need to be cooled below the critical temperature of superconductors used in constructing the cable to retain the superconductivity. With the advent of new superconductors whose critical temperatures having reached up to 134 K (Hg based), a need arises to find a suitable coolant which can accommodate the heating loads on the superconductors. The present work proposes, Supercritical Nitrogen (SCN) to be a feasible coolant to achieve the required cooling. Further, the feasibility of proposed coolant to be used in futuristic HTS cables is investigated by studying the thermophysical properties such as density, viscosity, specific heat and thermal conductivity with respect to temperature (T_C + 10 K) and pressure (P_C + 10 bar). In addition, few temperature dependent analytical functions are developed for thermophysical properties of SCN which are useful in predicting thermohydraulic performance (pressure drop, pumping power and cooling capacity) using numerical or computational techniques. Also, the developed analytical functions are used to calculate the pumping power and the temperature difference between inlet and outlet of HTS cable. These results are compared with those of liquid nitrogen (LN2) and found that the circulating pumping power required to pump SCN is significantly smaller than that to pump LN2. Further, it is found that the temperature difference between the inlet and outlet is smaller as compared to that when LN2 is used, SCN can be preferred to cool long length Hg based HTS cables. - Highlights: • Analytical functions are developed for thermophysical properties of Supercritical Nitrogen. • Error analysis shows extremely low errors in the developed analytical functions.

  17. Antenatal and postnatal sonographic imaging findings of a single ventricle presenting as double outlet right ventricle with rudimentary left ventricle and single atrium

    Directory of Open Access Journals (Sweden)

    Donboklang Lynser

    2015-11-01

    Full Text Available Congenital heart disease is a major cause of morbidity and mortality. Single ventricle is a rare finding and usually of left ventricular morphology. We present here interesting antenatal and postnatal echocardiographic findings of a baby having a rare single ventricle of right ventricular morphology with double outlet. Antenatally we saw a large ventricular septal defect indistinguishable from a single ventricle with left to right ventricular ratio of 1:1. Postnatally we saw a single ventricle having the outlets for both the main pulmonary artery and aortic root. The left ventricle is collapse with a rudimentary morphology possibly due to changes in hemodynamics after birth and absent of outlet from it.

  18. Design of a reactor inlet temperature controller for EBR-2 using state feedback

    International Nuclear Information System (INIS)

    Vilim, R.B.; Planchon, H.P.

    1990-01-01

    A new reactor inlet temperature controller for pool type liquid-metal reactors has been developed and will be tested in EBR-II. The controller makes use of modern control techniques to take into account stratification and mixing in the cold pool during normal operation. Secondary flowrate is varied so that the reactor inlet temperature tracks a setpoint while reactor outlet temperature, primary flowrate and secondary cold leg temperature are treated as exogenous disturbances and are free to vary. A disturbance rejection technique minimizes the effect of these disturbances on inlet temperature. A linear quadratic regulator improves inlet temperature response. Tests in EBR-II will provide experimental data for assessing the performance improvements that modern control can produce over the existing EBR-II analog inlet temperature controller. 10 refs., 8 figs

  19. Internal Flow of a High Specific-Speed Diagonal-Flow Fan (Rotor Outlet Flow Fields with Rotating Stall

    Directory of Open Access Journals (Sweden)

    Norimasa Shiomi

    2003-01-01

    Full Text Available We carried out investigations for the purpose of clarifying the rotor outlet flow fields with rotating stall cell in a diagonal-flow fan. The test fan was a high–specific-speed (ns=1620 type of diagonal-flow fan that had 6 rotor blades and 11 stator blades. It has been shown that the number of the stall cell is 1, and its propagating speed is approximately 80% of its rotor speed, although little has been known about the behavior of the stall cell because a flow field with a rotating stall cell is essentially unsteady. In order to capture the behavior of the stall cell at the rotor outlet flow fields, hot-wire surveys were performed using a single-slant hotwire probe. The data obtained by these surveys were processed by means of a double phase-locked averaging technique, which enabled us to capture the flow field with the rotating stall cell in the reference coordinate system fixed to the rotor. As a result, time-dependent ensemble averages of the three-dimensional velocity components at the rotor outlet flow fields were obtained. The behavior of the stall cell was shown for each velocity component, and the flow patterns on the meridional planes were illustrated.

  20. Non-iterative method to calculate the periodical distribution of temperature in reactors with thermal regeneration

    International Nuclear Information System (INIS)

    Sanchez de Alsina, O.L.; Scaricabarozzi, R.A.

    1982-01-01

    A matrix non-iterative method to calculate the periodical distribution in reactors with thermal regeneration is presented. In case of exothermic reaction, a source term will be included. A computer code was developed to calculate the final temperature distribution in solids and in the outlet temperatures of the gases. The results obtained from ethane oxidation calculation in air, using the Dietrich kinetic data are presented. This method is more advantageous than iterative methods. (E.G.) [pt

  1. A GIS Application to Explore Postal Retail Outlet Locations

    Directory of Open Access Journals (Sweden)

    Nikola Trubint

    2012-03-01

    Full Text Available The use of GIS in solving a wide variety of problems in postal operations is expanding. This approach provides the development and usage of new methods in spatial data analysis, as support in achieving a better quality of the decision-making process. The use of location analysis model based on GIS software is implemented in solving the Belgrade postal retail outlet problem. One of the most important experiences of model implementation is that the local environmental conditions have a significant impact on strategic as well as operational approach. A portion of the material included in the paper has resulted from the Serbian PTT and CPC (Canada Post Corporation joint project Location Analysis.

  2. Knowledge of practising radiographers of the supraspinatus outlet projection for shoulder impingement syndrome in the Eastern Cape, South Africa

    International Nuclear Information System (INIS)

    Williams, R.; Morton, D.G.

    2016-01-01

    Background/Aim: There are many projections in plain film imaging to demonstrate the specific aspects of the anatomy of the shoulder. However, reproducing the required projections can be challenging especially if radiographers are not familiar with the projections and their evaluation criteria. The aim of the study was to explore and describe the knowledge of practising radiographers regarding the supraspinatus outlet projection for shoulder impingement syndrome. Method: A quantitative, exploratory and descriptive design was followed. The population served as the sample and included all the practising radiographers in the public and private hospitals of a metropolitan municipality in the Eastern Cape, South Africa. A total of 84 respondents completed the structured, self-administered questionnaire. Results: The data revealed that in many cases, the majority of radiographers in the study, due to inadequate knowledge levels would not be able to produce an optimal radiographic image of the supraspinatus outlet. The results of the chi-squares indicated statistically significant differences (p < 0.05) between public and private hospitals regarding certain aspects of the scapular Y projection and SOP. Conclusion: It was found that the radiographers in the study had inadequate knowledge of scapular Y projections and SOPs in relation to SIS. Therefore, it is essential to ensure that radiographers are updated on their knowledge of radiographic practice on a continuous basis. - Highlights: • Many radiographers unable to produce an optimal image of the supraspinatus outlet. • Radiographers had poor knowledge of scapular Y and supraspinatus outlet projections. • It is essential that radiographers update their knowledge of radiographic practice.

  3. Performance of Inductors Attached to a Galvanizing Bath

    Science.gov (United States)

    Zhou, Xinping; Yuan, Shuo; Liu, Chi; Yang, Peng; Qian, Chaoqun; Song, Bao

    2013-12-01

    By taking a galvanizing bath with inductors from an Iron and Steel Co., Ltd as an example, the distributions of Lorentz force and generated heat in the inductor are simulated. As a result, the zinc flow and the temperature distribution driven by the Lorentz force and the generated heat in the inductor of a galvanizing bath are simulated numerically, and their characteristics are analyzed. The relationship of the surface-weighted average velocity at the outlet and the temperature difference between the inlet and the outlet and the effective power for the inductor is studied. Results show that with an increase in effective power for the inductor, the surface-weighted average velocity at the outlet and the temperature difference between the inlet and the outlet increase gradually. We envisage this work to lay a foundation for the study of the performance of the galvanizing bath in future.

  4. Soft sensing of system parameters in membrane distillation

    KAUST Repository

    Laleg-Kirati, Taous-Meriem

    2017-03-23

    Various examples of methods and systems are provided for soft sensing of system parameters in membrane distillation (MD). In one example, a system includes a MD module comprising a feed side and a permeate side separated by a membrane boundary layer; and processing circuitry configured to estimate feed solution temperatures and permeate solution temperatures of the MD module using monitored outlet temperatures of the feed side and the permeate side. In another example, a method includes monitoring outlet temperatures of a feed side and a permeate side of a MD module to determine a current feed outlet temperature and a current permeate outlet temperature; and determining a plurality of estimated temperature states of a membrane boundary layer separating the feed side and the permeate side of the MD module using the current feed outlet temperature and the current permeate outlet temperature.

  5. Infrared temperature and gas measurements at the Haderslev power and heat plan[Denmark]; Infraroede temperatur- og gasmaelinger Haderslev Kraftvarmevaerk

    Energy Technology Data Exchange (ETDEWEB)

    Clausen, Soennik

    2007-04-15

    Report describe results from a two week measurement campaign at Haderslev Kraftvarmevaerk in 2006 as a part of PSO-project 5727 'On-line optimization of waste incinerators'. Non-contact gas temperature and gas composition was measured simultaneously with a FTIR spectrometer coupled to a water-cooled fiber-optic probe. Gas temperature and H{sub 2}O, CO{sub 2}, CO, C{sub x}H{sub y} and HCl concentrations was extracted from measured spectra of emitted thermal radiation from gas slab over a 25 cm path. Measurements where performed in different positions to obtain a overview of flow behavior and conditions during stable operation and during a step in operation conditions, e.g. changing combustion air flows. Furthermore, surface temperature of grate was monitored with a thermal camera and a cross stack reference measurement on hot outlet gas was performed with a FTIR spectrometer. (au)

  6. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature

    NARCIS (Netherlands)

    van Halsema, Emo E.; Rauws, Erik A. J.; Fockens, Paul; van Hooft, Jeanin E.

    2015-01-01

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that

  7. Design of high temperature Engineering Test Reactor (HTTR)

    International Nuclear Information System (INIS)

    Saito, Shinzo; Tanaka, Toshiyuki; Sudo, Yukio

    1994-09-01

    Construction of High Temperature Engineering Test Reactor (HTTR) is now underway to establish and upgrade basic technologies for HTGRs and to conduct innovative basic research at high temperatures. The HTTR is a graphite-moderated and helium gas-cooled reactor with 30 MW in thermal output and outlet coolant temperature of 850degC for rated operation and 950degC for high temperature test operation. It is planned to conduct various irradiation tests for fuels and materials, safety demonstration tests and nuclear heat application tests. JAERI received construction permit of HTTR reactor facility in February 1990 after 22 months of safety review. This report summarizes evaluation of nuclear and thermal-hydraulic characteristics, design outline of major systems and components, and also includes relating R and D result and safety evaluation. Criteria for judgment, selection of postulated events, major analytical conditions for anticipated operational occurrences and accidents, computer codes used in safety analysis and evaluation of each event are presented in the safety evaluation. (author)

  8. Determining of the Parking Manoeuvre and the Taxi Blockage Adjustment Factor for the Saturation Flow Rate at the Outlet Legs of Signalized Intersections: Case Study from Rasht City (Iran)

    Science.gov (United States)

    Behbahani, Hamid; Jahangir Samet, Mehdi; Najafi Moghaddam Gilani, Vahid; Amini, Amir

    2017-10-01

    The presence of taxi stops within the area of signalized intersections at the outlet legs due to unnatural behaviour of the taxis, sudden change of lanes, parking manoeuvres activities and stopping the vehicle to discharge or pick up the passengers have led to reduction of saturation flow rate at the outlet leg of signalized intersections and increased delay as well as affecting the performance of a crossing lane. So far, in term of evaluating effective adjustment factors on saturation flow rate at the inlet legs of the signalized intersections, various studies have been carried out, however; there has not been any studies on effective adjustment factors on saturation flow rate at the inlet legs. Hence, the evaluating of the traffic effects of unique behaviours on the saturation flow rate of the outlet leg is very important. In this research the parking manoeuvre time and taxi blockage time were evaluated and analyzed based on the available lane width as well as determining the effective adjustment factors on the saturation flow rate using recording related data at four signalized intersections in Rasht city. The results show that the average parking manoeuvre time is a function of the lane width and is increased as the lane width is reduced. Also, it is suggested to use the values of 7.37 and 11.31 seconds, respectively for the average parking manoeuvre time and the average blockage time of taxies at the outlet legs of signalized intersections for the traffic designing in Rasht city.

  9. Surface Elevation Change of Transantarctic Outlet Glaciers using Historical Aerial Imagery and Structure-from-Motion Photogrammetry

    Science.gov (United States)

    Child, S. F.; Stearns, L. A.; Girod, L.

    2017-12-01

    Transantarctic Mountain outlet glaciers drain ice from the East Antarctic Ice Sheet to the Ross Ice Shelf and are generally considered to be stable. However, studies that assess these glaciers typically use data with coarse spatial resolutions (1 - 20 km) and span only the last 15 - 20 years. Here, we use trimetrogon aerial (TMA) photographs collected by the United States Geological Survey from 1960 - 1965 to create historical surface elevation maps. We construct elevations from both the vertical (0° nadir) and oblique photographs using MicMac, a Structure-from-Motion (SfM) software. With typical SfM processing, accurate ground control points (GCPs) are necessary for the best results; however, in situ GCPs are extremely sparse in Antarctica, so we manually identify GCPs using exposed rock outcrops in the WorldView imagery. The historical glacier surface elevations are then compared with present-day elevations derived from WorldView imagery. With this methodology, we assess how Transantarctic outlet glaciers have changed over 55 years. Recent studies indicate thinning of the eastern Ross Ice Shelf, where it borders the Transantarctic Mountains. With long-term records of glacier elevation change, we can differentiate whether ice shelf thinning is driven by changes in glacier or ocean dynamics. These results give us a better understanding of the long-term stability of East Antarctic outlet glaciers, which is essential in improving predictive models of ice sheet behavior.

  10. Numerical prediction and performance experiment in a deep-well centrifugal pump with different impeller outlet width

    Science.gov (United States)

    Shi, Weidong; Zhou, Ling; Lu, Weigang; Pei, Bing; Lang, Tao

    2013-01-01

    The existing research of the deep-well centrifugal pump mainly focuses on reduce the manufacturing cost and improve the pump performance, and how to combine above two aspects together is the most difficult and important topic. In this study, the performances of the deep-well centrifugal pump with four different impeller outlet widths are studied by the numerical, theoretical and experimental methods in this paper. Two stages deep-well centrifugal pump equipped with different impellers are simulated employing the commercial CFD software to solve the Navier-Stokes equations for three-dimensional incompressible steady flow. The sensitivity analyses of the grid size and turbulence model have been performed to improve numerical accuracy. The flow field distributions are acquired and compared under the design operating conditions, including the static pressure, turbulence kinetic energy and velocity. The prototype is manufactured and tested to certify the numerical predicted performance. The numerical results of pump performance are higher than the test results, but their change trends have an acceptable agreement with each other. The performance results indicted that the oversize impeller outlet width leads to poor pump performances and increasing shaft power. Changing the performance of deep-well centrifugal pump by alter impeller outlet width is practicable and convenient, which is worth popularizing in the engineering application. The proposed research enhances the theoretical basis of pump design to improve the performance and reduce the manufacturing cost of deep-well centrifugal pump.

  11. Could You Buy Me a Beer? Measuring Secondary Supply of Alcohol in Dutch On-Premise Outlets.

    Science.gov (United States)

    Roodbeen, Ruud T J; Geurtsen, Suzie; Schelleman-Offermans, Karen

    2018-01-01

    Alcohol is largely available for Dutch minors through on-premise secondary supply, which occurs when an adult furnishes an alcoholic drink to a minor in an on-premise outlet. Vendors allowing this secondary supply on their premises are in violation of the Dutch Licensing and Catering Act (legal age limit is 18 years old for the sale and possession of alcohol). Using existing mystery shopping protocols as a standard, our study objective was the development and field testing of a novel procedure, measuring vendors' compliance with secondary supply. Using a newly developed mystery shopping procedure, transfers of alcohol between young adult buyers and minors were staged in 109 Dutch on-premise outlets (cafes and bars) to measure vendors' compliance with secondary supply. In accordance with the Dutch Licensing and Catering Act, 29% of the vendors disallowed the secondary supply of alcohol to minors (32 of 109 attempts). During 40 attempts (of 109 attempts; 37%), the vendor asked for the identification document (ID) of the minor. Compliance after the ID was requested was 80% (32 of 40 attempts). During 8 attempts (20%), the minors were served even after the ID of the minor was requested. Mystery shopping is a suitable methodology for measuring compliance with secondary supply. Results show that alcohol is largely available for Dutch minors through secondary supply. Governments that intend to formulate and evaluate enforcement policies aimed at curbing high alcohol availability for minors are advised to use this novel procedure for monitoring compliance and to use these results for agenda setting and benchmarking.

  12. The Effect of Bladder Outlet Obstruction on alpha(1)- and beta-Adrenoceptor Expression and Function

    NARCIS (Netherlands)

    Barendrecht, Maurits M.; Frazier, Elfaridah P.; Vrydag, Wim; Alewijnse, Astrid E.; Peters, Stephan L. M.; Michel, Martin C.

    2009-01-01

    Aims: To explore possible changes in expression and/or function of alpha(1)- and beta-adrenoceptor subtypes as a cause for bladder dysfunction in a rat model of bladder outlet obstruction (BOO). Methods: BOO was induced in rats by partial urethral ligature. Contraction and relaxation experiments

  13. Bladder outlet obstruction due to a small midline prostatic cyst - diagnostic imaging and interventional radiological treatment

    International Nuclear Information System (INIS)

    Hueppe, T.; Kopka, L.; Friedrich, M.; Kuehn, M.

    1992-01-01

    We describe a rare case of a bladder outlet obstruction due to a midline prostatic cyst. In the following clinical apperance, diagnostic imaging and therapy by CT-guided punction are reported. Differential diagnosis and therapy are discussed. (orig.) [de

  14. Simulation of inlet and outlet riser break sequences in the N Reactor

    International Nuclear Information System (INIS)

    Bolander, M.A.; Fletcher, C.D.

    1988-02-01

    This report documents work performed at the Idaho National Engineering Laboratory (INEL) in support of the Westinghouse Hanford Company safety analyses of the N Reactor. The RELAP5/MOD2 computer code was used in analyzing two hypothetical transients. The computer code was modified specifically to simulate the refill behavior in the N Reactor process tubes. The transients analyzed were a double-ended rupture of an inlet riser column and a double-ended rupture of an outlet riser column

  15. Numerical analysis of a PCM thermal storage system with varying wall temperature

    International Nuclear Information System (INIS)

    Halawa, E.; Bruno, F.; Saman, W.

    2005-01-01

    Numerical analysis of melting and freezing of a PCM thermal storage unit (TSU) with varying wall temperature is presented. The TSU under analysis consists of several layers of thin slabs of a PCM subjected to convective boundary conditions where air flows between the slabs. The model employed takes into account the variations in wall temperature along the direction of air flow as well as the sensible heat. The paper discusses typical characteristics of the melting/freezing of PCM slabs in an air stream and presents some results of the numerical simulation in terms of air outlet temperatures and heat transfer rates during the whole periods of melting and freezing. Considerations in the design of the TSU are also given

  16. Unsteady Flow Dynamics and Acoustics of Two-Outlet Centrifugal Fan Design

    Science.gov (United States)

    Wong, I. Y. W.; Leung, R. C. K.; Law, A. K. Y.

    2011-09-01

    In this study, a centrifugal fan design with two flow outlets is investigated. This design aims to provide high mass flow rate but low noise performance. Two dimensional unsteady flow simulation with CFD code (FLUENT 6.3) is carried out to analyze the fan flow dynamics and its acoustics. The calculations were done using the unsteady Reynolds averaged Navier Stokes (URANS) approach in which effects of turbulence were accounted for using κ-ɛ model. This work aims to provide an insight how the dominant noise source mechanisms vary with a key fan geometrical paramters, namely, the ratio between cutoff distance and the radius of curvature of the fan housing. Four new fan designs were calculated. Simulation results show that the unsteady flow-induced forces on the fan blades are found to be the main noise sources. The blade force coefficients are then used to build the dipole source terms in Ffowcs Williams and Hawkings (FW-H) Equation for estimating their noise effects. It is found that one design is able to deliver a mass flow 34% more, but with sound pressure level (SPL) 10 dB lower, than the existing design .

  17. Structural Properties of Cruciferin and Napin of Brassica napus (Canola Show Distinct Responses to Changes in pH and Temperature

    Directory of Open Access Journals (Sweden)

    Suneru P. Perera

    2016-09-01

    Full Text Available The two major storage proteins identified in Brassica napus (canola were isolated and studied for their molecular composition, structural characteristics and the responses of structural features to the changes in pH and temperature. Cruciferin, a complex of six monomers, has a predominantly β-sheet-containing secondary structure. This protein showed low pH unstable tertiary structure, and distinctly different solubility behaviour with pH when intact in the seed cellular matrix. Cruciferin structure unfolds at pH 3 even at ambient temperature. Temperature-induced structure unfolding was observed above the maximum denaturation temperature of cruciferin. Napin was soluble in a wider pH range than cruciferin and has α-helices dominating secondary structure. Structural features of napin showed less sensitivity to the changes in medium pH and temperature. The surface hydrophobicity (S0 and intrinsic fluorescence of tryptophan residue appear to be good indicators of cruciferin unfolding, however they were not the best to demonstrate structural changes of napin. These two storage proteins of B. napus have distinct molecular characteristics, therefore properties and functionalities they provide are contrasting rather than complementary.

  18. Plasmatron with expanding channel of outlet electrode and its applications

    International Nuclear Information System (INIS)

    Chinnov, V.F.; Isakajev, E.Kh.; Ivanov, P.P.; Sinkevich, O.A.; Tyuftyaev, A.S.

    2000-01-01

    A serious industrial application is found for the plasmatron with expanding channel of outlet electrode - hardening and nitriding surface treatment of railway wheels. Several plasma installations are under operation at the engine houses of Moscow Railways. More than 12 000 wheel sets have been treated up to now. Results are evident: wheel life doubles due to plasma treatment. The plasmatron developed essentially in an empiric way is now under heavy investigation both theoretically and experimentally. High precision measurements of nitrogen emission spectra are expected to be used directly for accurate calculation of radiation heat loss term in a quasi-one dimensional flow code. (Authors)

  19. Analytical method for determining the channel-temperature distribution

    International Nuclear Information System (INIS)

    Kurbatov, I.M.

    1992-01-01

    The distribution of the predicted temperature over the volume or cross section of the active zone is important for thermal calculations of reactors taking into account random deviations. This requires a laborious calculation which includes the following steps: separation of the nominal temperature field, within the temperature range, into intervals, in each of which the temperature is set equal to its average value in the interval; determination of the number of channels whose temperature falls within each interval; construction of the channel-temperature distribution in each interval in accordance with the weighted error function; and summation of the number of channels with the same temperature over all intervals. This procedure can be greatly simplified with the help of methods which eliminate numerous variant calculations when the nominal temperature field is open-quotes refinedclose quotes up to the optimal field according to different criteria. In the present paper a universal analytical method is proposed for determining, by changing the coefficients in the channel-temperature distribution function, the form of this function that reflects all conditions of operation of the elements in the active zone. The problem is solved for the temperature of the coolant at the outlet from the reactor channels

  20. High temperature and high performance light water cooled reactors operating at supercritical pressure, research and development

    International Nuclear Information System (INIS)

    Oka, Y.; Koshizuka, S.; Katsumura, Y.; Yamada, K.; Shiga, S.; Moriya, K.; Yoshida, S.; Takahashi, H.

    2003-01-01

    The concept of supercritical-pressure, once-through coolant cycle nuclear power plant (SCR) was developed at the University of Tokyo. The research and development (R and D) started worldwide. This paper summarized the conceptual design and R and D in Japan. The big advantage of the SCR concept is that the temperatures of major components such as reactor pressure vessel, control rod drive mechanisms, containments, coolant pumps, main steam piping and turbines are within the temperatures of the components of LWR and supercritical fossil fired power plants (FPP) in spite of the high outlet coolant temperature. The experience of these components of LWR and supercritical fossil fired power plants will be fully utilized for SCR. The high temperature, supercritical-pressure light water reactor is the logical evolution of LWR. Boiling evolved from circular boilers, water tube boilers and once-through boilers. It is the reactor version of the once-through boiler. The development from LWR to SCR follows the history of boilers. The goal of the R and D should be the capital cost reduction that cannot be achieved by the improvement of LWR. The reactor can be used for hydrogen production either by catalysis and chemical decomposition of low quality hydrocarbons in supercritical water. The reactor is compatible with tight lattice fast core for breeders due to low outlet coolant density, small coolant flow rate and high head coolant pumps

  1. Development of Very High Temperature Reactor Technology

    International Nuclear Information System (INIS)

    Lee, Won Jae; Noh, J. M.; Kim, Y. H.

    2009-04-01

    For an efficient production of nuclear hydrogen, the VHTR (Very High Temperature Gas-cooled Reactor) of 950 .deg. C outlet temperature and the interfacing system for the hydrogen production are required. We have developed various evaluation technologies for the performance and safety of VHTR through the accomplishment of this project. First, to evaluate the performance of VHTR, a series of analyses has been performed such as core characteristics at 950 .deg. C, applicability of cooled-vessel, intermediate loop system and high temperature structural integrity. Through the analyses of major accidents such as HPCC and LPCC and the analysis of the risk/performance-informed method, VHTR safety evaluation has been also performed. In addition, various design analysis codes have been developed for a nuclear design, system loop design, system performance analysis, air-ingress accident analysis, fission product/tritium transport analysis, graphite structure seismic analysis and hydrogen explosion analysis, and they are being verified and validated through a lot of international collaborations

  2. Treatment practices of households and antibiotic dispensing in medicine outlets in developing countries: The case of Ghana

    DEFF Research Database (Denmark)

    Tersbøl, Britt Pinkowski

    2018-01-01

    in households and the antibiotic dispensing practices of medicine sales outlets in Eastern region, Ghana. Method: Twice-weekly illness recall visits were made to 12 households in three rural communities over eight consecutive weeks. Detailed fieldnotes were taken and analysed using a thematic approach....... Quantitative counts of health events and treatment were also conducted. Dispensing practices were systematically observed and documented in three rural and three urban medicine outlets for analysis. Result: Fever, abdominal, and respiratory symptoms were the most common causes of ill-health in the 12...... an integral part of healthcare in the study settings and the qualitative data provides a contextual understanding of over-the-counter antibiotic acquisition and use. Inappropriate antibiotic use is apparent in the study settings. Stricter regulation of the pharmaceutical sector, training of dispensers...

  3. Histopathological changes induced in an animal model by potentially pathogenic Enterococcus faecalis strains recovered from ready-to-eat food outlets in Osun State, Nigeria.

    Science.gov (United States)

    Olawale, Adetunji Kola; David, Oluwole Moses; Oluyege, Adekemi Olubukunola; Osuntoyinbo, Richard Temitope; Laleye, Solomon Anjuwon; Famurewa, Oladiran

    2015-01-01

    Enterococci have been implicated as an emerging important cause of several diseases and multiple antibiotic resistance. However, there is little information about the prevalence of pathogenic and/or antibiotic-resistant Enterococcus faecalis in ready-to-eat foods in Nigeria. Here we report the pathogenic potential of three selected antibiotic-resistant E. faecalis strains isolated from food canteens and food outlets with different virulence determinant genes, including EFC 12 (with gel (+), esp (+), cylA (+), and asa1 (+)), EFT 148 (with gel (+), ace (+), and asa1 (+)), and EFS 18 (with esp (+) and cylA (+)) in an animal model. Enterococcemia, hematological parameters, and histopathological changes in organ tissues were examined in experimental animals. The results showed differences in enterococcemia and hematological parameters between the control group and experimental animal group. Enterococcemia was observed for 7 days, and the animal group infected with EFC 12 showed the highest growth rate, followed by EFT 148, with the lowest growth rate seen in the EFS 18-infected group. White blood cell count, packed cell volume, and platelets were significantly reduced (Pfood canteens and food outlets; hence, there is a need for strict adherence to good hygiene practices in the study area owing to the epidemiological significance of foods.

  4. Measurement of reactivity temperature coefficient by noise method in a power reactor

    International Nuclear Information System (INIS)

    Aguilar, O.

    1986-07-01

    The temperature reactivity coefficient was estimated on the basis of noise measurements performed in a PWR. The magnitude of the coefficient was evaluated by relating the values of the APSD and CPSD between ex-core neutron detector signals and fuel assembly outlet thermocouple in the low frequency range. Comparison with δρ/δT measurements performed in PWR by standard methods supports the validity of the results. (author)

  5. Experimental determination of the bulk temperature values in a nonisothermal flow of the chemically reacting nitrogen tetroxide

    International Nuclear Information System (INIS)

    Devojno, A.N.; Kolykhan, L.I.; Stepanenko, V.N.; Tverkovkin, B.E.; Uyutov, G.I.

    1975-01-01

    The technique and results of an experimental determination of mean mass temperatures of a cooled chemically active nitrogen tetroxide flowing in a circular tube under turbulent flow conditions are considered. The parameters range as follows: pressure-from 8.10 5 to 16.10 5 H/m 2 , flow temperature-from 140 deg to 550 deg C, Reynolds number-from 3,1.1g 5 , flow velocity-from 3.5 to 45 m/s. The gas temperature along the length of the test tube is measured with movable probe with a mixer and thermocouple in a stainless steel capillary 2mm in dia and the wall 0,2 mm thick. The mean-square deviations of measured temperature values from the predicted ones are about -0.9 and +1.8%. The obtained data show the predicted temperature values to be somewhat lower than the measured ones, the difference increasing with the distance to the test tube outlet. It may be explained by both unaccounted systematic experimental errors and errors in calculating the mean mass flow temperatures. The investigation described confirms the possibility of an experimental determination of the mean gas temperature along the cooled channel length by mean mass of a movable mixer with a single thermocouple

  6. Lateral sphincteromyotomy in patients with outlet obstruction after surgery for Hirschsprung's disease and short-segment disease

    DEFF Research Database (Denmark)

    Vorm, Hanne N; Jensen, Susanne I; Qvist, Niels

    2002-01-01

    The results of lateral sphincteromyotomy (LSM) including the external sphincter in patients with severe outlet obstruction (OO) and constipation refractory to medical treatment after surgery for Hirschsprung's disease (HD) or with short-segment disease were evaluated. The parents filled out a det...

  7. The impact of interventions to promote healthier ready-to-eat meals (to eat in, to take away or to be delivered) sold by specific food outlets open to the general public: a systematic review.

    Science.gov (United States)

    Hillier-Brown, F C; Summerbell, C D; Moore, H J; Routen, A; Lake, A A; Adams, J; White, M; Araujo-Soares, V; Abraham, C; Adamson, A J; Brown, T J

    2017-02-01

    Ready-to-eat meals sold by food outlets that are accessible to the general public are an important target for public health intervention. We conducted a systematic review to assess the impact of such interventions. Studies of any design and duration that included any consumer-level or food-outlet-level before-and-after data were included. Thirty studies describing 34 interventions were categorized by type and coded against the Nuffield intervention ladder: restrict choice = trans fat law (n = 1), changing pre-packed children's meal content (n = 1) and food outlet award schemes (n = 2); guide choice = price increases for unhealthier choices (n = 1), incentive (contingent reward) (n = 1) and price decreases for healthier choices (n = 2); enable choice = signposting (highlighting healthier/unhealthier options) (n = 10) and telemarketing (offering support for the provision of healthier options to businesses via telephone) (n = 2); and provide information = calorie labelling law (n = 12), voluntary nutrient labelling (n = 1) and personalized receipts (n = 1). Most interventions were aimed at adults in US fast food chains and assessed customer-level outcomes. More 'intrusive' interventions that restricted or guided choice generally showed a positive impact on food-outlet-level and customer-level outcomes. However, interventions that simply provided information or enabled choice had a negligible impact. Interventions to promote healthier ready-to-eat meals sold by food outlets should restrict choice or guide choice through incentives/disincentives. Public health policies and practice that simply involve providing information are unlikely to be effective. © 2016 The Authors. Obesity Reviews published by John Wiley & Sons Ltd on behalf of World Obesity Federation.

  8. System dynamic analyses on the JKJ mercury target and cold moderator systems

    International Nuclear Information System (INIS)

    Takahashi, Toshio; Kaminaga, Masanori; Kinoshita, Hidetaka; Aso, Tomokazu; Haga, Katsuhiro; Hino, Ryutaro

    2001-01-01

    The temperature responses of major points in a mercury target cooling system and in a cold moderator system of JKJ (JAERI/KEK Joint Project) were simulated by the analytical code MATLAB (SIMULINK). As a result, it was made clear that non-control of mercury temperature is the best way to control the mercury target cooling system. If the mercury temperature of the system is controlled by the PID control system using an outlet temperature of heat exchanger, the PID control system shows the characteristics of an on-off control system, and the temperature cannot be controlled. Analytical results also showed that mercury temperature remained below the boiling point of 356degC under 0.1 MPa during a transient at one cooling pump trip. Analytical results for the cold moderator system showed that the outlet temperature of cold moderator vessels could be kept within a temperature range of 1 k during steady-state conditions. (author)

  9. The Preliminary Study of High Temperature Gas Cooled Reactors (HTGRs) Technology

    International Nuclear Information System (INIS)

    Nurfarhana Ayuni Joha; Izhar Abu Hussin; Ridzuan Abdul Mutalib

    2015-01-01

    High Temperature Gas Cooled Reactors (HTGRs) have attracted worldwide interest because of their high outlet temperatures, which allow them to be used for applications beyond electricity generation. HTGRs have been built and operated since as far back as the 1970s. Experimental and demonstration reactors of this type have operated in China, Great Britain, Germany, Japan, and the United States of America. This paper is written to share the valuable knowledge and information of HTGRs technology as a mean to enrich peoples understanding of the technology. This paper will present the technological features of HTGRs that allow for a modular design with inherently safe characteristics. (author)

  10. 77 FR 74454 - Media Outlets for Publication of Legal and Action Notices in the Southern Region

    Science.gov (United States)

    2012-12-14

    ... Outlets for Publication of Legal and Action Notices in the Southern Region AGENCY: Forest Service, USDA. ACTION: Notice. SUMMARY: Deciding Officers in the Southern Region will publish notice of decisions... newspapers listed in the SUPPLEMENTARY INFORMATION section of this notice. The Southern Region consists of...

  11. Thermo-economic optimization of heat recovery steam generator for a range of gas turbine exhaust temperatures

    International Nuclear Information System (INIS)

    Nadir, Mahmoud; Ghenaiet, Adel; Carcasci, Carlo

    2016-01-01

    Highlights: • Thermo-economic optimization of HRSG configurations. • The maximum value of the net present value was targeted for the economic optimization. • Three level HRSG is the best option in respect of power output and high priced medium. • Two level HRSG is the best for net benefit in low and intermediate priced mediums. - Abstract: This paper illustrates the effect of selling price on the optimum design parameters of a heat recovery steam generator (HRSG) and the selection of its ideal configuration for an outlet temperature range of 350–650 °C. The Particle Swarm Optimization (PSO) method was used, considering the steam cycle specific work as an objective to be maximized, the net present value as another objective to be maximized for the economic optimization and a combination of both. Three configurations of heat recovery steam generators are considered with one, two and three pressure levels and a reheat. The results show that, the three pressure level system is the best configuration from a thermodynamic point of view, but with respect to the economical aspect the two pressure levels is the best configuration for the low and medium selling prices (0.04 $/kW h, 0.08 $/kW h and 0.2 $/kW h), whereas the three pressure level configuration would only be interesting for a high selling price of 0.3 $/kW h and a temperature range 450–600 °C. For a temperature of 650 °C, the high cost of the three level system leads to a decrease in the net present value. As the selling price increases the optimized design parameters of the three pressure level HRSG based on economic or thermodynamic optimization are similar. The obtained results are used to elaborate a new correlation relating the net present value with the gas turbine outlet temperature, gas mass flow rate, number of levels of HRSG and selling price.

  12. Validation of turbulence models for LMFBR outlet plenum flows

    International Nuclear Information System (INIS)

    Chen, Y.B.; Golay, M.W.

    1977-01-01

    Small scale experiments involving water flows are used to provide mean flow and turbulence field data for LMFBR outlet plenum flows. Measurements are performed at Reynolds number (Re) values of 33000 and 70000 in a 1/15 - scale FFTF geometry and at Re = 35000 in a 3/80-scale CRBR geometry. The experimental behavior is predicted using two different two-equation turbulence model computer programs, TEACH-T and VARR-II. It is found that the qualitative nature of the flow field within the plenum depends strongly upon the distribution of the mean inlet flow field, importantly also upon the degree of inlet turbulence, and also upon the turbulent momentum exchange model used in the calculations. In the FFTF geometry, the TEACH-T predictions agree well with the experiments. 7 refs

  13. Recent Trends in Alcohol Outlet Density, Distances from Educational Institutions and Sales Campaigns in Chiang Mai Municipality (Metropolitan), Thailand: Should We Be Worried for Our Youths?

    Science.gov (United States)

    Thaikla, Kanittha; Jiraporncharoen, Wichuda; Semmahasak, Sukho; Likhitsathian, Surinporn; Angkurawaranon, Chaisiri

    2016-03-01

    Since 2008, alcohol control policies in Thailand have been considered quite comprehensive. The study aimed to investigate the subsequent changes in alcohol outlet density and patterns of sales promotion, which may be useful for monitoring the effectiveness of policies and helpful for planning prevention strategies to reduce alcohol-related harms. All accessible routes in the Chiang Mai Municipality (Metropolitan: CMM) were surveyed in 2009, 2011 and 2014. During each round of survey, the geographical coordinates of alcohol outlets and educational institutions in the CMM were recorded using the Global Navigation Satellite System (GNSS). In addition, alcohol sales campaigns were documented. Three main trends emerged by 2014. The first was that alcohol outlet density had increased. Second, the average distances between alcohol outlets and educational institutions decreased with evidence of clustering near educational institutions. Lastly, increased advertising of alcohol promotions and new sales campaigns not previously seen in 2009 and 2011 promoted high volume drinking in Chiang Mai Municipality (CMM). Our study reflects the potential gaps between some of the intended consequences of alcohol control policies and the actural trends emerging in Chiang Mai, Thailand. Young people in CMM may be at a particularly high risk for alcohol-related problems due to high exposure to alcohol outlets and sales campaigns near their educational institution. © The Author 2015. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  14. Research of Dust Field Optimization Distribution Based on Parameters Change of Air Duct Outlet in Fully Mechanized Excavation Face of Coal Mine

    Science.gov (United States)

    Gong, Xiao-Yan; Xia, Zhi-Xin; Wu, Yue; Mo, Jin-Ming; Zhang, Xin-Yi

    2017-12-01

    Aiming at the problem of dust accumulation and pollution risk rising sharply in fully mechanized excavation face, which caused by the unreasonable air duct outlet airflow under the long distance driving, this paper proposes a new idea to optimize the distribution of dust by changing the angle, caliber and the front and rear distance of air duct outlet. Taking the fully mechanized excavation face of Ningtiaota coal mine which located in Shaanxi province as the research object, the numerical simulation scheme of dust field was established, the safety hazard of the distribution of original dust field was simulated and analyzed, the numerical simulation and optimization analysis of the dust distribution by changing the angle, caliber and the front and rear distance of air duct outlet was carried out, and the adjustment scheme of the optimized dust distribution was obtained, which provides a theoretical basis for reducing the probability of dust explosion and the degree of pollution.

  15. Location, location, location: Assessing the spatial patterning between marijuana licenses, alcohol outlets and neighborhood characteristics within Washington state.

    Science.gov (United States)

    Tabb, Loni Philip; Fillmore, Christina; Melly, Steven

    2018-04-01

    The availability of marijuana products is becoming increasingly prevalent across the United States (US), many states are allowing for the production, processing, and retailing of these products for medical and/or recreational use. The purpose of this study is to: (1) examine the spatial patterning of marijuana licenses, and (2) examine the impact of alcohol outlets in addition to other neighborhood characteristics on marijuana licenses within the state of Washington. This cross-sectional observational study examined 1458 census tracts in Washington state from 2017, using marijuana and alcohol data from the Washington State Liquor and Cannabis Board as well as neighborhood characteristics data from the American Community Survey 2011-2015 5-year estimates. We used exploratory and formal spatial regression methods, including integrated nested Laplace approximation within a Bayesian statistical framework, to address the study aims. Our results indicate there is significant spatial patterning of marijuana producers and processors across the state. We also found that all marijuana licenses are located in poorer census tracts, and marijuana retailers are co-located in census tracts with off-premises alcohol outlets. Our study provides empirical evidence of the relationship between marijuana licenses, alcohol outlets, and neighborhood characteristics, and has important implications for policymakers in other states currently considering legalizing marijuana-products for medical and/or recreational use. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Formation and evolution of monoepoxy fatty acids in thermoxidized olive and sunflower oils and quantitation in used frying oils from restaurants and fried-food outlets.

    Science.gov (United States)

    Velasco, Joaquín; Marmesat, Susana; Bordeaux, Olivier; Márquez-Ruiz, Gloria; Dobarganes, Carmen

    2004-07-14

    The formation and evolution of monoepoxy fatty acids, arising from oleic and linoleic acids, were investigated in olive oil and conventional sunflower oil, representatives of monounsaturated and polyunsaturated oils, respectively, during thermoxidation at 180 degrees C for 5, 10, and 15 h. Six monoepoxy fatty acids, cis-9,10- and trans-9,10-epoxystearate, arising from oleic acid, and cis-9,10-, trans-9,10-, cis-12,13-, and trans-12,13-epoxyoleate, arising from linoleic acid, were analyzed by gas chromatography after oil derivatization to fatty acid methyl esters. Considerable amounts, ranging from 4.29 to 14.24 mg/g of oil in olive oil and from 5.10 to 9.44 mg/g of oil in sunflower oil, were found after the heating periods assayed. Results showed that the monoepoxides quantitated constituted a major group among the oxidized fatty acid monomers formed at high temperature. For similar levels of degradation, higher contents of the monoepoxides were found in olive oil than in sunflower oil. Ten used frying oils from restaurants and fried-food outlets in Spain were analyzed to determine the contents of the monoepoxides in real frying oil samples. Levels ranged from 3.37 to 14.42 mg/g of oil. Results show that, for similar degradation levels, the monoepoxides were more abundant in the monounsaturated oils than in the polyunsaturated oils.

  17. Prediction of Flow and Temperature Distributions in a High Flux Research Reactor Using the Porous Media Approach

    Directory of Open Access Journals (Sweden)

    Shanfang Huang

    2017-01-01

    Full Text Available High thermal neutron fluxes are needed in some research reactors and for irradiation tests of materials. A High Flux Research Reactor (HFRR with an inverse flux trap-converter target structure is being developed by the Reactor Engineering Analysis Lab (REAL at Tsinghua University. This paper studies the safety of the HFRR core by full core flow and temperature calculations using the porous media approach. The thermal nonequilibrium model is used in the porous media energy equation to calculate coolant and fuel assembly temperatures separately. The calculation results show that the coolant temperature keeps increasing along the flow direction, while the fuel temperature increases first and decreases afterwards. As long as the inlet coolant mass flow rate is greater than 450 kg/s, the peak cladding temperatures in the fuel assemblies are lower than the local saturation temperatures and no boiling exists. The flow distribution in the core is homogeneous with a small flow rate variation less than 5% for different assemblies. A large recirculation zone is observed in the outlet region. Moreover, the porous media model is compared with the exact model and found to be much more efficient than a detailed simulation of all the core components.

  18. Risky consumption habits and safety of fluid milk available in retail sales outlets in Viçosa, Minas Gerais State, Brazil.

    Science.gov (United States)

    Pieri, Fabio Alessandro; Colombo, Monique; Merhi, Carolina Milner; Juliati, Vinícius Augusto; Ferreira, Marcello Sebe; Nero, Marcelo Antônio; Nero, Luis Augusto

    2014-06-01

    This study aimed to assess raw milk consumption habits in the urban population of Viçosa, Minas Gerais, Brazil, and the microbiological safety and quality of the fluid milk available in retail sales outlets in the same region. A simplified questionnaire regarding raw milk consumption was applied to the persons responsible for food acquisition in 411 residences. The regular consumption of raw milk was observed by 18.5% of the interviewers, and lack of knowledge of possible risks related to this food product. Microbiological safety and quality were assessed for raw (n=69), pasteurized (n=80), and ultra-high-temperature (UHT)-treated milk (n=80) by analyzing the counts of mesophilic aerobes, coliforms, and Escherichia coli, and detection of Listeria monocytogenes and Salmonella spp.; raw milk samples were also subjected to enumeration of coagulase-positive Staphylococcus. Concerning raw milk, 59.4% of the samples were considered as produced in inadequate hygienic conditions, 5.8% of the samples presented counts of coagulase-positive Staphylococcus lower than 100 colony-forming units (CFU)/mL, and no samples presented with positive results for L. monocytogenes or Salmonella spp. All pasteurized and UHT milk samples presented with low counts of mesophilic aerobes and coliforms, while L. monocytogenes and Salmonella spp. were absent. The data demonstrated that raw milk was consumed by the population studied. Despite the absence of potential hazards, raw milk was of poor hygienic quality, in contrast with the processed fluid milk available in retail sales outlets that was safe and of good hygienic quality, highlighting the suitability of pasteurized and UHT milk for human consumption.

  19. Strategies for optimizing the opening of the outlet air circuit's nozzle to improve the efficiency of the PEMFC generator

    Energy Technology Data Exchange (ETDEWEB)

    Tirnovan, R. [Power Systems Department, Technical University of Cluj-Napoca (Romania); Giurgea, S.; Miraoui, A. [Fuel Cell Lab, University of Technology of Belfort-Montbeliard (France)

    2011-04-15

    The aim of this study is the optimal dimensioning of the air circuit's outlet nozzle in relation with the load duration curve, for a given PEMFC generator, in order to maximize the PEMFC efficiency and to increase the net outlet power. The steady state PEMFC operation has been taken into account. The model of the PEMFC system used in the work is based on a moving least squares technique. A centrifugal compressor has been taken into account, and the operating line of the compressor has been evaluated for an optimal fixed opening of the outlet nozzle. A multi-level optimization procedure has been implemented to solve the optimization problem. The developed algorithm is useful to design an optimum air subsystem, reducing the number of the control variables and the consequences of the dynamic behavior of a controlled electric adjustable valve on the PEMFC performance. The results of the work can contribute to the improvement of the PEMFC generator reliability and of its cost/performance ratio. (author)

  20. Association of compartment defects in anorectal and pelvic floor dysfunction with female outlet obstruction constipation (OOC) by dynamic MR defecography.

    Science.gov (United States)

    Li, M; Jiang, T; Peng, P; Yang, X-Q; Wang, W-C

    2015-04-01

    Chronic constipation affects more than 17% of the global population worldwide, and up to 50% of patients were outlet obstruction constipation (OOC). Women and the elderly are most likely to be affected, due to female-specific risk factors, such as menopause, parity and multiparity. The aim of our study was to investigate the association of compartment defects in anorectal and pelvic floor dysfunction with female outlet obstruction constipation (OOC) by MR defecography. Fifty-six consecutive women diagnosed with outlet obstruction constipation from October 2009 to July 2011 were included. They were categorized into the following groups: anorectal disorder only group (27 patients) and anorectal disorder plus multi-compartment pelvic disorder group (29 patients). Relevant measurements were taken at rest, during squeezing and straining. Anismus was significantly more common in the anorectal disorder group compared to the multi-compartment pelvic disorder group. Conversely, rectocele, rectal prolapse, and descending perineum were significantly more common in the multi-compartment pelvic disorder group compared to the anorectal disorder group. Of the total 56 OOC patients, 34 (60.7%) exhibited anismus and 38 (67.9%) rectocele. Among the anismus patients, there were 8 patients (23.5%) with combined cystocele, and 6 patients (17.6%) with combined vaginal/cervical prolapse. Among the rectocele patients, there were 23 patients (60.5%) with combined cystocele and 18 patients (47.4%) with combined vaginal/cervical prolapse. With respect to anorectal defects, 13 anismus patients (38.2%) were with signal posterior pelvic defects, 4 rectocele patients (10.5%) presented with signal posterior pelvic defects. Inadequate defecatory propulsion due to outlet obstruction constipation is often associated with multi-compartment pelvic floor disorders, whereas not about dyssynergic defecation.

  1. Global Trend Analysis of Multi-decade Soil Temperature Records Show Soils Resistant to Warming

    Science.gov (United States)

    Frey, S. D.; Jennings, K.

    2017-12-01

    Soil temperature is an important determinant of many subterranean ecological processes including plant growth, nutrient cycling, and carbon sequestration. Soils are expected to warm in response to increasing global surface temperatures; however, despite the importance of soil temperature to ecosystem processes, less attention has been given to examining changes in soil temperature over time. We collected long-term (> 20 years) soil temperature records from approximately 50 sites globally, many with multiple depths (5 - 100 cm), and examined temperature trends over the last few decades. For each site and depth we calculated annual summer means and conducted non-parametric Mann Kendall trend and Sen slope analysis to assess changes in summer soil temperature over the length of each time series. The mean summer soil temperature trend across all sites and depths was not significantly different than zero (mean = 0.004 °C year-1 ± 0.033 SD), suggesting that soils have not warmed over the observation period. Of the subset of sites that exhibit significant increases in temperature over time, site location, depth of measurement, time series length, and neither start nor end date seem to be related to trend strength. These results provide evidence that the thermal regime of soils may have a stronger buffering capacity than expected, having important implications for the global carbon cycle and feedbacks to climate change.

  2. Boundary layer models for calving marine outlet glaciers

    Directory of Open Access Journals (Sweden)

    C. Schoof

    2017-10-01

    Full Text Available We consider the flow of marine-terminating outlet glaciers that are laterally confined in a channel of prescribed width. In that case, the drag exerted by the channel side walls on a floating ice shelf can reduce extensional stress at the grounding line. If ice flux through the grounding line increases with both ice thickness and extensional stress, then a longer shelf can reduce ice flux by decreasing extensional stress. Consequently, calving has an effect on flux through the grounding line by regulating the length of the shelf. In the absence of a shelf, it plays a similar role by controlling the above-flotation height of the calving cliff. Using two calving laws, one due to Nick et al. (2010 based on a model for crevasse propagation due to hydrofracture and the other simply asserting that calving occurs where the glacier ice becomes afloat, we pose and analyse a flowline model for a marine-terminating glacier by two methods: direct numerical solution and matched asymptotic expansions. The latter leads to a boundary layer formulation that predicts flux through the grounding line as a function of depth to bedrock, channel width, basal drag coefficient, and a calving parameter. By contrast with unbuttressed marine ice sheets, we find that flux can decrease with increasing depth to bedrock at the grounding line, reversing the usual stability criterion for steady grounding line location. Stable steady states can then have grounding lines located on retrograde slopes. We show how this anomalous behaviour relates to the strength of lateral versus basal drag on the grounded portion of the glacier and to the specifics of the calving law used.

  3. The larvae of congeneric gastropods showed differential responses to the combined effects of ocean acidification, temperature and salinity.

    Science.gov (United States)

    Zhang, Haoyu; Cheung, S G; Shin, Paul K S

    2014-02-15

    The tolerance and physiological responses of the larvae of two congeneric gastropods, the intertidal Nassarius festivus and subtidal Nassarius conoidalis, to the combined effects of ocean acidification (pCO2 at 380, 950, 1250 ppm), temperature (15, 30°C) and salinity (10, 30 psu) were compared. Results of three-way ANOVA on cumulative mortality after 72-h exposure showed significant interactive effects in which mortality increased with pCO2 and temperature, but reduced at higher salinity for both species, with higher mortality being obtained for N. conoidalis. Similarly, respiration rate of the larvae increased with temperature and pCO2 level for both species, with a larger percentage increase for N. conoidalis. Larval swimming speed increased with temperature and salinity for both species whereas higher pCO2 reduced swimming speed in N. conoidalis but not N. festivus. The present findings indicated that subtidal congeneric species are more sensitive than their intertidal counterparts to the combined effects of these stressors. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Effect of the temperature on the spray drying of Roselle extracts (Hibiscus sabdariffa L.).

    Science.gov (United States)

    Gonzalez-Palomares, Salvador; Estarrón-Espinosa, Mirna; Gómez-Leyva, Juan Florencio; Andrade-González, Isaac

    2009-03-01

    The effect of the drying temperature on the volatile components and sensory acceptance of the Roselle (Hibiscus sabdariffa) extract in powder was investigated. The Roselle extraction was carried out by maceration with 7 L of 30% ethanol (v/v), 560 g of fresh Roselle calyces for 168 h. The Roselle extracts were spray dried at different temperatures 150, 160, 170, 180, 190, 200 and 210 degrees C, giving different outlet values about yield and final moisture. The volatile compounds in Roselle extract and dried samples were performed using needles of solid phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS HP-5890). Twenty volatile compounds were identified in the extracts among them terpenoids, esters, hydrocarbons and aldehydes. Fourteen volatile compounds were identified in the powder sample, but only ten were present in the Roselle extract. This indicates that some compounds were lost and some others were generated due to a degradation process. An acceptability sensory analysis showed that the best powder sample was the Roselle extract dehydrated using temperature between 190 degrees C and 200 degrees C (pRoselle extracts ranging from 3.4 to 3.9. It was concluded that the spray drying temperature of the Roselle extracts has an effect on the volatile compounds losses.

  5. A novel perovskite oxide chemically designed to show multiferroic phase boundary with room-temperature magnetoelectricity

    Science.gov (United States)

    Fernández-Posada, Carmen M.; Castro, Alicia; Kiat, Jean-Michel; Porcher, Florence; Peña, Octavio; Algueró, Miguel; Amorín, Harvey

    2016-09-01

    There is a growing activity in the search of novel single-phase multiferroics that could finally provide distinctive magnetoelectric responses at room temperature, for they would enable a range of potentially disruptive technologies, making use of the ability of controlling polarization with a magnetic field or magnetism with an electric one (for example, voltage-tunable spintronic devices, uncooled magnetic sensors and the long-searched magnetoelectric memory). A very promising novel material concept could be to make use of phase-change phenomena at structural instabilities of a multiferroic state. Indeed, large phase-change magnetoelectric response has been anticipated by a first-principles investigation of the perovskite BiFeO3-BiCoO3 solid solution, specifically at its morphotropic phase boundary between multiferroic polymorphs of rhombohedral and tetragonal symmetries. Here, we report a novel perovskite oxide that belongs to the BiFeO3-BiMnO3-PbTiO3 ternary system, chemically designed to present such multiferroic phase boundary with enhanced ferroelectricity and canted ferromagnetism, which shows distinctive room-temperature magnetoelectric responses.

  6. Designing vertical shafts for mines with deepening and outlet of rock to the operating level

    Energy Technology Data Exchange (ETDEWEB)

    Durov, Ye.M.

    1983-01-01

    Requirements for designing the cross sections of central shafts are examined, as well as those for determining the productivity of lifts and equipment of the shafts with a condition of use in a subsequent technological layout of their deepening with outlet of the rock to the operating level. Typical cross sections of skip and cellular shafts are given.

  7. 16 CFR Appendix F to Part 436 - Sample Item 20(5) Table-Projected New Franchised Outlets

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Sample Item 20(5) Table-Projected New Franchised Outlets F Appendix F to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. F Appendix F to Part...

  8. 16 CFR Appendix C to Part 436 - Sample Item 20(2) Table-Transfers of Franchised Outlets

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Sample Item 20(2) Table-Transfers of Franchised Outlets C Appendix C to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. C Appendix C to Part...

  9. Development of very high temperature reactor design technology

    International Nuclear Information System (INIS)

    Lee, Won Jae; Noh, Jan Man

    2012-04-01

    or an efficient production of nuclear hydrogen, the VHTR (Very High Temperature Gas-cooled Reactor) of 950 .deg. C outlet temperature and the interfacing system for the hydrogen production are required. We have developed various evaluation technologies for the performance and safety of VHTR through the accomplishment of this project. First, to evaluate the performance of VHTR, a series of analyses has been performed such as core characteristics at 950 .deg. C, applicability of cooled-vessel, intermediate loop system and high temperature structural integrity. Through the analyses of major accidents such as HPCC and LPCC and the analysis of the risk/performance-informed method, VHTR safety evaluation has been also performed. In addition, various design analysis codes have been developed for a nuclear design, system loop design, system performance analysis, fission product/tritium transport analysis, core thermo-fluid analysis, system layout analysis, graphite structure seismic analysis and hydrogen exposion analysis, and they are being verified and validated through a lot of international collaborations

  10. Development of Very High Temperature Reactor Design Technology

    International Nuclear Information System (INIS)

    Lee, Won Jae; Noh, J. M.; Kim, K. S.

    2007-05-01

    To develop design technologies for the VHTR (Very High Temperature Gas-cooled Reactor) of 950 .deg. C outlet temperature for an efficient hydrogen production, key studies were performed, which include evaluation technology for the performance and safety of VHTR, and development of design and analysis codes. First, to evaluate the performance of VHTR, a series of analyses has been carried out for core characteristics at 950 .deg. C, cooled-vessel adopting internal flow path through the graphite structure, compact heat exchanger with periodic channel configuration, intermediate loop system, risk/performance-informed method, and high temperature structural integrity. Through the analyses of major accidents such as HPCC and LPCC, safety evaluation of both VHTR and RCCS has been also performed. In addition, prototype codes have been developed for a nuclear design, system loop design, system performance analysis, air-ingress accident analysis, fission product/tritium transport analysis, graphite structure seismic analysis and hydrogen explosion analysis, and they are being verified and validated through a lot of international collaborations

  11. Radiological evaluation of double-outlet right ventricle - An analysis of cinecardioangiography in 44 cases -

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheong Hee; Yeon, Kyung Mo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1984-03-15

    Double-outlet right ventricle is defined as follows: both great arteries arise completely or nearly completely from the right ventricle; neither semilunar valve is in fibrous continuity with either atrioventricular valve; and usually a ventricular septal defect is present and the only outlet from the left ventricle. A total of 44 cases of double-outlet right ventricle is analyzed, in which cineangiocardiographies were done at the Department of Radiology, Seoul National University Hospital in recent 4 year and 6 months, with specific reference to the segmental combinations, the height of conus, the relationship of great arteries, the location of ventricular septal defects, and associated anomalies. The results were as follows; 1. Among 44 cases, 36 cases had normal cardiac position, 4 cases had dextrocardia with situs inversus 2 cases had dextrocardia with situs solitus, 1 case had levocardia with situs inversus, and another 1 case had mesocardia with situs ambiguus. 2. Segmental sets were [S,D,D] in 36 cases, [I,L,L] in 3 cases, [I,D,D] in 2 cases, [S,D,L], [S,L,L] and [A,D,D] in 1 case respectively. 3. All cases had bilateral conus. Aortic valve rings were same level as pulmonary valve rings in 25 cases, lower than pulmonary valve rings in 17 cases in which 15 cases were type A., and higher than pulmonary valve rings in 2 cases. 4. The relation of the great arteries were normal in 15 cases, side-by-side in 13 cases, dextromalposition in 13 cases, and levomal position in 3 cases. 5. The position of the ventricular septal defects with respect to the origins of the great arteries is subaortic (type A and type B) in 23 cases, subpulmonary (type C) in 13 cases, doubly committed (type D) in 3 cases, and uncommitted (type E) in 5 cases. 6. Associated cardiac malformations are pulmonary stenosis in 24 which had all cases of type A and type E, aortic stenosis in 6 which were only in type C, left SVC in 6, abnormality of atrioventricular valve in 5, single coronary artery

  12. Fractionating power and outlet stream polydispersity in asymmetrical flow field-flow fractionation. Part I: isocratic operation.

    Science.gov (United States)

    Williams, P Stephen

    2016-05-01

    Asymmetrical flow field-flow fractionation (As-FlFFF) has become the most commonly used of the field-flow fractionation techniques. However, because of the interdependence of the channel flow and the cross flow through the accumulation wall, it is the most difficult of the techniques to optimize, particularly for programmed cross flow operation. For the analysis of polydisperse samples, the optimization should ideally be guided by the predicted fractionating power. Many experimentalists, however, neglect fractionating power and rely on light scattering detection simply to confirm apparent selectivity across the breadth of the eluted peak. The size information returned by the light scattering software is assumed to dispense with any reliance on theory to predict retention, and any departure of theoretical predictions from experimental observations is therefore considered of no importance. Separation depends on efficiency as well as selectivity, however, and efficiency can be a strong function of retention. The fractionation of a polydisperse sample by field-flow fractionation never provides a perfectly separated series of monodisperse fractions at the channel outlet. The outlet stream has some residual polydispersity, and it will be shown in this manuscript that the residual polydispersity is inversely related to the fractionating power. Due to the strong dependence of light scattering intensity and its angular distribution on the size of the scattering species, the outlet polydispersity must be minimized if reliable size data are to be obtained from the light scattering detector signal. It is shown that light scattering detection should be used with careful control of fractionating power to obtain optimized analysis of polydisperse samples. Part I is concerned with isocratic operation of As-FlFFF, and part II with programmed operation.

  13. Are Customers Satisfied With Healthier Food Options At South African Fast-Food Outlets?

    OpenAIRE

    Michael C. Cant; Ricardo Machado; Melanie Gopaul

    2014-01-01

    Fast-food consumption has been a staple for many people; however, due to rising health concerns, there has been an increasing interest in the consumption of healthier food both in South Africa and elsewhere. Many consumers are demanding better quality foods that offer nutritional benefits. This global trend has led to fast-food outlets adding healthier food options to their menus. Limited literature exists on customer satisfaction with regards to the food quality of these healthier food optio...

  14. Development of high temperature gas cooled reactor in China

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Wentao [Paul Scherrer Institute, Villigen (Switzerland). Dept. of Nuclear Energy and Safety; Schorer, Michael [Swiss Nuclear Forum, Olten (Switzerland)

    2018-02-15

    High temperature gas cooled reactor (HTGR) is one of the six Generation IV reactor types put forward by Generation IV International Forum (GIF) in 2002. This type of reactor has high outlet temperature. It uses Helium as coolant and graphite as moderator. Pebble fuel and ceramic reactor core are adopted. Inherit safety, good economy, high generating efficiency are the advantages of HTGR. According to the comprehensive evaluation from the international nuclear community, HTGR has already been given the priority to the research and development for commercial use. A demonstration project of the High Temperature Reactor-Pebble-�bed Modules (HTR-PM) in Shidao Bay nuclear power plant in China is under construction. In this paper, the development history of HTGR in China and the current situation of HTR-PM will be introduced. The experiences from China may be taken as a reference by the international nuclear community.

  15. [Late outlet strut fracture of an aortic Björk-Shiley and embolization of the prosthetic disc].

    Science.gov (United States)

    Brochet, E; Bougis de Brux, M A; Assayag, P; Benacin, Y; Gamerman, G; Guerot, C; Valère, P E

    1988-09-01

    A new case of late fracture of an outlet strut in a convexo-concave Björk-Shiley valve is reported. The fracture occurred 6 years after aortic implantation of the valve and was responsible for aorto-iliac embolization by the prosthetic disc and death of the patient from cardiogenic shock. This not uncommon complication of the Björk-Shiley valve prosthesis is usually ascribed to the relative fragility of its outlet strut welded to the metallic ring and subjected to strong pressures. Although most cases were observed within the first two years of prosthetic valve insertion, and mainly with valves manufactured in 1981 and 1982, our case and a few others demonstrate the possibility of late rupture. Cardiologists must be aware of this possible complication, since in some favourable cases it can be diagnosed at an early stage and the patient's life can be saved by an emergency operation.

  16. Analysis of the gas outlets of the nuclear power plants relation between nuclides determined by gamma-spectrometry

    International Nuclear Information System (INIS)

    Mihalik, J.

    2008-01-01

    The National Radiation Protection Institute is interested in the long-time study of the noble gases outlets of nuclear power plants. One of the causes of monitoring the gas outlet is independent assessment of the influence nuclear power plant on the environment. Result of this analysis confirms the correlation between 88 Kr and 85m Kr in all technological compartments. Except the internal flue of the first production unit, the high correlation coefficient was determined between 88 Kr - 135 Xe and 85m Kr - 135 Xe. The analysis presented by this paper suggests that the highest correlation coefficient was always reached between 88 Kr and 85 mKr. Its values approached to 1. Similar results were confirmed between 85m Kr - 135 Xe and 88 Kr - 1 35 Xe. As far as the ratio of the specific activity concerns, we found certain congruence between 2006 and 2007. (authors)

  17. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction: A Comparison Between 2 Brands of Stents.

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-07-01

    Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.

  18. Have drivers at alcohol outlets changed their behavior after the new traffic law?

    Directory of Open Access Journals (Sweden)

    Raquel B. De Boni

    2014-03-01

    Full Text Available Objective: In an attempt to reduce high levels of traffic crashes, a new legislation was approved in Brazil in 2008. This study aimed to assess behavioral change among drivers who had drunk at alcohol outlets (AO after implementation of the law. Method: A three-stage probability sampling survey was conducted in Porto Alegre, state of Rio Grande do Sul, Brazil. Individuals seen leaving AOs after drinking were approached (n=3,018. Selected drivers (n=683 answered a structured interview, were breathalyzed, and had saliva specimens collected for drug screening. Results: Overall, 60.3% (SE 4.5 of drivers reported they did not change their behavior. Among those who reported behavioral changes, most reported drinking less as their main strategy toward safer driving behavior. Variables independently associated with behavior change included having drunk at a high outlet density area (odds ratio [OR] 1.7 [1.1-2.8] and having a favorable opinion about the law (OR 4.3 [2.1-8.9]. Conclusions: Our findings suggest that awareness of the law has not been enough to promote behavioral change. As most drivers had a favorable opinion of the law and this variable was found to be the strongest predictor of behavior change, efforts to better integrate education and enforcement seem to be pivotal and might be well received by the population.

  19. Fundamental conceptual design of the experimental multi-purpose high-temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Shimokawa, Junichi; Yasuno, Takehiko; Yasukawa, Shigeru; Mitake, Susumu; Miyamoto, Yoshiaki

    1975-06-01

    The fundamental conceptual design of the experimental multi-purpose very high-temperature gas-cooled reactor (experimental VHTR of thermal output 50 MW with reactor outlet-gas temperature 1,000 0 C) has been carried out to provide the operation modes of the system consisting of the reactor and the heat-utilization system, including characteristics and performance of the components and safety of the plant system. For the heat-utilization system of the plant, heat distribution, temperature condition, cooling system constitution, and the containment facility are specified. For the operation of plant, testing capability of the reactor and controlability of the system are taken into consideration. Detail design is made of the fuel element, reactor core, reactivity control and pressure vessel, and also the heat exchanger, steam reformer, steam generator, helium circulator, helium-gas turbine, and helium-gas purification, fuel handling, and engineered safety systems. Emphasis is placed on providing the increase of the reactor outlet-gas temperature. Fuel element design is directed to the prismatic graphite blocks of hexagonal cross-section accommodating the hollow or tubular fuel pins sheathed in graphite sleeve. The reactor core is composed of 73 fuel columns in 7 stages, concerning the reference design MK-II. Orificing is made in the upper portion of core; one orifice for every 7 fuel columns. Average core power density is 2.5 watts/cm 3 . Fuel temperature is kept below 1,300 0 C in rated power. The main components, i.e. pressure vessel, reformer, gas turbine and intermediate heat exchanger are designed in detail; the IHX is of a double-shell and helically-wound tube coils, the reformer is of a byonet tube type, and the turbine-compressor unit is of an axial flow type (turbine in 6 stages and compressor in 16 stages). (auth.)

  20. Simulation tests for temperature mixing in a core bottom model of the HTR-module

    International Nuclear Information System (INIS)

    Damm, G.; Wehrlein, R.

    1992-01-01

    Interatom and Siemens are developing a helium-cooled Modular High Temperature Reactor. Under nominal operating conditions temperature differences of up to 120deg C will occur in the 700deg C hot helium flow leaving the core. In addition, cold gas leakages into the hot gas header can produce even higher temperature differences in the coolant flow. At the outlet of the reactor only a very low temperature difference of maximum ± 15deg C is allowed in order to avoid damages at the heat exchanging components due to alternating thermal loads. Since it is not possible to calculate the complex flow behaviour, experimental investigations of the temperature mixing in the core bottom had to be carried out in order to guarantee the necessary reduction of temperature differences in the helium. The presented air simulation tests in a 1:2.9 scaled plexiglas model of the core bottom showed an extremely high mixing rate of the hot gas header and the hot gas duct of the reactor. The temperature mixing of the simulated coolant flow as well as the leakage flows was larger than 95%. Transfered to reactor conditions this means a temperature difference of only ± 3deg C for the main flow at a quite resonable pressure drop. For the cold gas leakages temperature differences in the hot gas up to 400deg C proved to be permissible. The results of the simulation experiments in the Aerodynamic Test Facility of Interatom permitted to design a shorter bottom reflector of the core. (orig.)

  1. A stratified random survey of the proportion of poor quality oral artesunate sold at medicine outlets in the Lao PDR – implications for therapeutic failure and drug resistance

    Directory of Open Access Journals (Sweden)

    Vongsack Latsamy

    2009-07-01

    Full Text Available Abstract Background Counterfeit oral artesunate has been a major public health problem in mainland SE Asia, impeding malaria control. A countrywide stratified random survey was performed to determine the availability and quality of oral artesunate in pharmacies and outlets (shops selling medicines in the Lao PDR (Laos. Methods In 2003, 'mystery' shoppers were asked to buy artesunate tablets from 180 outlets in 12 of the 18 Lao provinces. Outlets were selected using stratified random sampling by investigators not involved in sampling. Samples were analysed for packaging characteristics, by the Fast Red Dye test, high-performance liquid chromatography (HPLC, mass spectrometry (MS, X-ray diffractometry and pollen analysis. Results Of 180 outlets sampled, 25 (13.9% sold oral artesunate. Outlets selling artesunate were more commonly found in the more malarious southern Laos. Of the 25 outlets, 22 (88%; 95%CI 68–97% sold counterfeit artesunate, as defined by packaging and chemistry. No artesunate was detected in the counterfeits by any of the chemical analysis techniques and analysis of the packaging demonstrated seven different counterfeit types. There was complete agreement between the Fast Red dye test, HPLC and MS analysis. A wide variety of wrong active ingredients were found by MS. Of great concern, 4/27 (14.8% fakes contained detectable amounts of artemisinin (0.26–115.7 mg/tablet. Conclusion This random survey confirms results from previous convenience surveys that counterfeit artesunate is a severe public health problem. The presence of artemisinin in counterfeits may encourage malaria resistance to artemisinin derivatives. With increasing accessibility of artemisinin-derivative combination therapy (ACT in Laos, the removal of artesunate monotherapy from pharmacies may be an effective intervention.

  2. A new method for measurement of subcoracoid outlet and its relationship to rotator cuff pathology at MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Porter, N.A.; Singh, J.; Tins, B.J.; Lalam, R.K.; Tyrrell, P.N.M.; Cassar-Pullicino, V.N. [Robert Jones and Agnes Hunt Orthopaedic Hospital, Department of Radiology, Oswestry, Shropshire (United Kingdom)

    2015-09-15

    Orthopaedic surgical studies have shown that variations in the vertical distance between the tip of the coracoid process and the supra-glenoid tubercle alter the shape of the subcoracoid outlet. Our objective was to measure the vertical distance between the coracoid tip and the supra-glenoid tubercle (CTGT) on MR and to assess whether this showed better correlation with rotator cuff pathology compared with the axial coraco-humeral distance. A retrospective review was performed of 100 consecutive shoulder MR arthrograms. Vertical distance between the coracoid tip and the supraglenoid tubercle was measured in the sagittal oblique plane. Separate assessment was then made of tendon pathology of the subscapularis, supraspinatus and long head of biceps tendons. Axial coraco-humeral distance was then measured. Correlation between tendon abnormalities and the two measurements was then made. Of the 100 cases, 42 had subscapularis tendon lesions, 21 had lesions of the long head of biceps and 53 had supraspinatus tendon lesions. Mean vertical distance from the coracoid tip to supraglenoid tubercle was greater in those with lesions of any of these tendons and was statistically significant for the supraspinatus group (P = 0.005). Reduced axial coraco-humeral distance was also seen in patients with tendinopathy, although with less statistically significant difference (p = 0.059). Our results support orthopaedic studies that have shown that the vertical distance between the coracoid tip and the supraglenoid tubercle increases the incidence and risk of rotator cuff disease by altering the shape of the subcoracoid outlet. (orig.)

  3. Heat sources for glacial ice melt in a West Greenland tidewater outlet glacier fjord: The role of subglacial freshwater discharge

    DEFF Research Database (Denmark)

    Bendtsen, Jørgen; Mortensen, John; Lennert, Kunuk

    2015-01-01

    The melting of tidewater outlet glaciers from the Greenland Ice Sheet contributes significantly to global sea level rise. Accelerated mass loss is related to melt-processes in front of calving glaciers, yet the role of ocean heat transports is poorly understood. Here we present the first direct...... of the area near the glacier showed that ice melt was mainly due to ocean heat transport and that direct plume-associated melt was only important in periods with high meltwater discharge rates of ~100 m3 s−1. Ocean mixing outside of the plume area was thus the primary heat source for melting glacier ice....

  4. Evidence for validity of five secondary data sources for enumerating retail food outlets in seven American Indian Communities in North Carolina

    Science.gov (United States)

    2012-01-01

    Background Most studies on the local food environment have used secondary sources to describe the food environment, such as government food registries or commercial listings (e.g., Reference USA). Most of the studies exploring evidence for validity of secondary retail food data have used on-site verification and have not conducted analysis by data source (e.g., sensitivity of Reference USA) or by food outlet type (e.g., sensitivity of Reference USA for convenience stores). Few studies have explored the food environment in American Indian communities. To advance the science on measuring the food environment, we conducted direct, on-site observations of a wide range of food outlets in multiple American Indian communities, without a list guiding the field observations, and then compared our findings to several types of secondary data. Methods Food outlets located within seven State Designated Tribal Statistical Areas in North Carolina (NC) were gathered from online Yellow Pages, Reference USA, Dun & Bradstreet, local health departments, and the NC Department of Agriculture and Consumer Services. All TIGER/Line 2009 roads (>1,500 miles) were driven in six of the more rural tribal areas and, for the largest tribe, all roads in two of its cities were driven. Sensitivity, positive predictive value, concordance, and kappa statistics were calculated to compare secondary data sources to primary data. Results 699 food outlets were identified during primary data collection. Match rate for primary data and secondary data differed by type of food outlet observed, with the highest match rates found for grocery stores (97%), general merchandise stores (96%), and restaurants (91%). Reference USA exhibited almost perfect sensitivity (0.89). Local health department data had substantial sensitivity (0.66) and was almost perfect when focusing only on restaurants (0.91). Positive predictive value was substantial for Reference USA (0.67) and moderate for local health department data (0

  5. Field validation of food outlet databases: the Latino food environment in North Carolina, USA.

    Science.gov (United States)

    Rummo, Pasquale E; Albrecht, Sandra S; Gordon-Larsen, Penny

    2015-04-01

    Obtaining valid, reliable measures of food environments that serve Latino communities is important for understanding barriers to healthy eating in this at-risk population. The primary aim of the study was to examine agreement between retail food outlet data from two commercial databases, Nielsen TDLinx (TDLinx) for food stores and Dun & Bradstreet (D&B) for food stores and restaurants, relative to field observations of food stores and restaurants in thirty-one census tracts in Durham County, NC, USA. We also examined differences by proportion of Hispanic population (Spanish language. One hundred and seventy-four food stores and 337 restaurants in Durham County, NC, USA. We found that overall sensitivity of food store listings in TDLinx was higher (64 %) than listings in D&B (55 %). Twenty-five food stores were characterized by auditors as Latino food stores, with 20 % identified in TDLinx, 52 % in D&B and 56 % in both sources. Overall sensitivity of restaurants (68 %) was higher than sensitivity of Latino restaurants (38 %) listed in D&B. Sensitivity did not differ substantially by Hispanic composition of neighbourhoods. Our findings suggest that while TDLinx and D&B commercial data sources perform well for total food stores, they perform less well in identifying small and independent food outlets, including many Latino food stores and restaurants.

  6. Parameter Sensitivity Study for Typical Expander-Based Transcritical CO2 Refrigeration Cycles

    Directory of Open Access Journals (Sweden)

    Bo Zhang

    2018-05-01

    Full Text Available A sensitivity study was conducted for three typical expander-based transcritical CO2 cycles with the developed simulation model, and the sensitivities of the maximum coefficient of performance (COP to the key operating parameters, including the inlet pressure of gas cooler, the temperatures at evaporator inlet and gas cooler outlet, the inter-stage pressure and the isentropic efficiency of expander, were obtained. The results showed that the sensitivity to the gas cooler inlet pressure differs greatly before and after the optimal gas cooler inlet pressure. The sensitivity to the intercooler outlet temperature in the two-stage cycles increases sharply to near zero and then keeps almost constant at intercooler outlet temperature of higher than 45 °C. However, the sensitivity stabilizes near zero when the evaporator inlet temperature is very low of −26.1 °C. In two-stage compression with an intercooler and an expander assisting in driving the first-stage compressor (TEADFC cycle, an abrupt change in the sensitivity of maximum COP to the inter-stage pressure was observed, but disappeared after intercooler outlet temperature exceeds 50 °C. The sensitivity of maximum COP to the expander isentropic efficiency increases almost linearly with the expander isentropic efficiency.

  7. 3D numerical simulation of fluid–solid coupled heat transfer with variable property in a LBE-helium heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Fei, E-mail: chenfei@iet.cn [Institute of Engineering Thermophysics, Chinese Academy of Sciences, 11 Beisihuanxi Road, Beijing 100190 (China); North China University of Water Resources and Electric Power, 36 Beihuan Road, Zhengzhou, Henan 450011 (China); Cai, Jun, E-mail: caijun@iet.cn [Institute of Engineering Thermophysics, Chinese Academy of Sciences, 11 Beisihuanxi Road, Beijing 100190 (China); Li, Xunfeng, E-mail: lixunfeng@iet.cn [Institute of Engineering Thermophysics, Chinese Academy of Sciences, 11 Beisihuanxi Road, Beijing 100190 (China); Huai, Xiulan, E-mail: hxl@iet.cn [Institute of Engineering Thermophysics, Chinese Academy of Sciences, 11 Beisihuanxi Road, Beijing 100190 (China); Wang, Yongwei, E-mail: wangyongwei@iet.cn [Institute of Engineering Thermophysics, Chinese Academy of Sciences, 11 Beisihuanxi Road, Beijing 100190 (China)

    2014-07-01

    Highlights: • Heat transfer in heat exchanger can be improved by increasing helium's flow rate. • The outlet temperature of helium decreases with increasing helium's flow rate. • Balance is necessary between good heat transfer and high helium outlet temperature. - Abstract: LBE-helium experimental loop of ADS (LELA) and LBE-helium heat exchanger have been designed and constructed with the supporting of the “ADS Transmutation System” project of Chinese Academy of Sciences. In order to investigate the flow and heat transfer characteristics between LBE and helium, 3D numerical simulation of fluid–solid coupled heat transfer with variable property in the LBE-helium heat exchanger is conducted in the present study. The effects of mass-flow-rates of helium and LBE in the shell-side and tube-side on the heat transfer performance are addressed. It is found that the heat transfer performance can be significantly improved by increasing helium mass-flow-rate in the shell-side. In order to easily and quickly obtain the outlet temperatures of helium and LBE, a concept of modified effectiveness is introduced and correlated as the function of tube-side to shell-side heat capacity rate ratio. The results show that the outlet temperature of helium decreases with increasing helium mass-flow-rate. Therefore, considering the utilization of high-temperature helium in the future, for example power generation, there should be a tradeoff between good heat transfer performance and high outlet helium temperature when confirming helium mass-flow-rate.

  8. Analysis on blow-down transient in water ingress accident of high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Wang, Yan; Zheng, Yanhua; Li, Fu; Shi, Lei

    2014-01-01

    Water ingress into the primary circuit is generally recognized as one of the severe accidents with potential hazard to the modular high temperature gas-cooled reactor, which will cause a positive reactivity introduction with the increase of steam density in reactor core to enhance neutron slowing-down, also the chemical corrosion of graphite fuel elements and the damage of reflector structure material. The increase of the primary pressure may result in the opening of the safety valves, consequently leading the release of radioactive isotopes and flammable water gas. The research on water ingress transient is significant for the verification of inherent safety characteristics of high temperature gas-cooled reactor. The 200 MWe high temperature gas-cooled reactor (HTR-PM), designed by the Institute of Nuclear and New Energy Technology of Tsinghua University, is exampled to be analyzed in this paper. The design basis accident (DBA) scenarios of double-ended guillotine break of single heat-exchange tube (steam generator heat-exchange tube rupture) are simulated by the thermal-hydraulic analysis code, and some key concerns which are relative to the amount of water into the reactor core during the blow-down transient are analyzed in detail. The results show that both of water mass and steam ratio of the fluid spouting from the broken heat-exchange tube are affected by break location, which will increase obviously with the broken location closing to the outlet of the heat-exchange tube. The double-ended guillotine rupture at the outlet of the heat-exchange will result more steam penetrates into the reactor core in the design basis accident of water ingress. The mass of water ingress will also be affected by the draining system. It is concluded that, with reasonable optimization on design to balance safety and economy, the total mass of water ingress into the primary circuit of reactor could be limited effectively to meet the safety requirements, and the pollution of

  9. Structure optimization of CFB reactor for moderate temperature FGD

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yuan; Zhang, Jie; Zheng, Kai; You, Changfu [Tsinghua Univ., Beijing (China). Dept. of Thermal Engineering; Ministry of Education, Beijing (China). Key Lab. for Thermal Science and Power Engineering

    2013-07-01

    The gas velocity distribution, sorbent particle concentration distribution and particle residence time in circulating fluidized bed (CFB) reactors for moderate temperature flue gas desulfurization (FGD) have significant influence on the desulfurization efficiency and the sorbent calcium conversion ratio for sulfur reaction. Experimental and numerical methods were used to investigate the influence of the key reactor structures, including the reactor outlet structure, internal structure, feed port and circulating port, on the gas velocity distribution, sorbent particle concentration distribution and particle residence time. Experimental results showed that the desulfurization efficiency increased 5-10% when the internal structure was added in the CFB reactor. Numerical analysis results showed that the particle residence time of the feed particles with the average diameter of 89 and 9 {mu}m increased 40% and 17% respectively, and the particle residence time of the circulating particles with the average diameter of 116 {mu}m increased 28% after reactor structure optimization. The particle concentration distribution also improved significantly, which was good for improving the contact efficiency between the sorbent particles and SO{sub 2}. In addition, the optimization guidelines were proposed to further increase the desulfurization efficiency and the sorbent calcium conversion ratio.

  10. Sustainability and Efficiency Improvements of Gas-Cooled High Temperature Reactors

    International Nuclear Information System (INIS)

    Marmier, Alain

    2012-01-01

    This thesis covers 3 fundamental aspects of High Temperature Reactor (HTR) performance: fuel testing under irradiation for maximized safety and sustainability, fuel architecture for improved economy and sustainability, and a novel Balance of Plant concept to enable future high-tech process heat applications with minimized R and D. The HTR concept features important inherent and passive safety characteristics: high thermal inertia and good thermal conductivity of the core; a negative Doppler coefficient; high quality of fuel elements and low power density. These features keep the core temperature within safe boundaries and minimise fission product release, even in case of severe accidents. The Very High Temperature reactor (VHTR) is based on the same safety concept as the initial HTR, but it aims at offering better economy with a higher reactor outlet temperature (and thus efficiency) and a high fuel discharge burn-up (and thus better sustainability). The inherent safety features of HTR have been demonstrated in small pebble-bed reactors in practice, but have to be replicated for reactors with industrially relevant size and power. An increase of the power density (in order to increase the helium coolant outlet temperature) leads to higher fuel temperatures and therefore higher fuel failure probability. The core of a pebble-bed reactor consists of 6 cm diameter spheres (pebbles) that form a randomly packed porous bed, which is cooled by high pressure helium. These pebbles contain thousands of 1 mm diameter fuel particles baked into a graphite matrix. These fuel particles, in turn, consist of a fuel kernel with successive coatings of pyrocarbon and silicon carbide layers. The coating layers are designed to contain the fission products that build up during operation of the reactor. The feasibility and performance of the fuel requires experimental verification in view of fuel qualification and licensing. For HTR fuel, the required test string comprises amongst others

  11. Microchip-calorimetry of organic charge transfer complex which shows superconductivity at low temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Muraoka, Yuki [Department of Chemistry, Graduate School of Science, Osaka University, Machikaneyama 1-1, Toyonaka, Osaka 560-0043 (Japan); Yamashita, Satoshi [RIKEN, Hirosawa 2-1, Wako, Saitama 351-0198 (Japan); Yamamoto, Takashi [Department of Chemistry, Graduate School of Science, Osaka University, Machikaneyama 1-1, Toyonaka, Osaka 560-0043 (Japan); Nakazawa, Yasuhiro, E-mail: nakazawa@chem.sci.osaka-u.ac.jp [Department of Chemistry, Graduate School of Science, Osaka University, Machikaneyama 1-1, Toyonaka, Osaka 560-0043 (Japan); Institute for Molecular Science, Nishigonaka 38, Myodaiji, Okazaki 444-8585 (Japan)

    2012-03-20

    Highlights: Black-Right-Pointing-Pointer Organic charge transfer salt of {kappa}-(BEDT-TTF){sub 2}Cu[N(CN){sub 2}]Br shows superconductivity. Black-Right-Pointing-Pointer We succeeded to detect thermal anomaly microchip device TCG3880. Black-Right-Pointing-Pointer Development details of the calorimeter and the detection system is presented. Black-Right-Pointing-Pointer The magnetic fields dependence shows typical character of layered superconductor. - Abstract: We carried out thermodynamic measurements of organic charge transfer complex of {kappa}-(BEDT-TTF){sub 2}Cu[N(CN){sub 2}]Br, where BEDT-TTF is bis(ethylenedithio)tetrathiafulvalene by TCG3880 chip device in order to examine capability of the chip calorimeter at low temperature region and under magnetic fields. TCG3880 chip is mounted on a {sup 3}He cryostat available in combination with a superconductive magnet up to 7 T. Thermal anomalies related to the glass-like freezing of ethylene groups of BEDT-TTF molecules and the superconductive transition were observed. A frequency dependence of the thermal anomaly of the glass formation and a magnetic fields dependence of the thermal anomaly of the superconductive transition are reported. The results presented in this work demonstrate that the TCG3880 is quite useful for thermodynamic investigations of the organic charge transfer complex with much reduced sample quantity as compared with those of relaxation and adiabatic calorimetry.

  12. Salt Marshes as Monitors of Late Holocene Outlet Glacier Retreat

    Science.gov (United States)

    Wake, L. M.; Woodroffe, S.; Long, A. J.; Milne, G. A.

    2014-12-01

    New proxy sea-level records extracted from salt marshes in the vicinity of Jakobshavn Isbrae (Pakitsoq; 69.51°N, 50.74°W) and at previous sites in central western Greenland (Sisimiut; 66.47°N, 53.61°W and Aasiaat; 68.69°N, 52.88°W) are analyzed with respect to their ability to act as proximal tide gauges detecting mass balance changes in nearby outlet glaciers associated with the transition from the Little Ice Age ("LIA", 1400-1850AD) to the Industrial Period (>1850AD). Data at Pakitsoq demonstrate that sea-level rose at a rate of 3.5 ±1.7 mm/yr prior to 1850AD and slowed to 0.3 ±0.6mm/yr thereafter, producing a slowdown in sea level of 3.2 ± 1.8 mm/yr. A similar slowdown, occurring at 1600AD, is observed at Aasiaat and Sisimiut. We interpret these observed changes using a glacial isostatic adjustment model of sea-level change truncated at degree and order 4096, with an aim to determine if the sea-level data can be used to place constraints on changes in Jakobshavn Isbrae and/or Kangiata Nunaata Sermia (Nuuk fjord) during this period. Modelled sea level at Pakitsoq is insensitive to the location of thickening (thinning) associated with grounding line advance (retreat) and the rate of advance and retreat but is sensitive to the change point in time between periods of growth associated with LIA expansion (sea level rise) and the onset of 19th century recession (sea level fall) of Jakobshavn Isbrae. We conclude that the change in sea-level rate observed at Pakitsoq circa 1850AD marks the onset of post LIA retreat of this outlet glacier. Conversely, the modelled sea-level response to the retreat of Kangiata Nunaata Sermia from its LIA maximum at ca. 1761AD is below the detection threshold of the salt marsh record at Sisimiut.

  13. Field validation of secondary data sources: a novel measure of representativity applied to a Canadian food outlet database.

    Science.gov (United States)

    Clary, Christelle M; Kestens, Yan

    2013-06-19

    Validation studies of secondary datasets used to characterize neighborhood food businesses generally evaluate how accurately the database represents the true situation on the ground. Depending on the research objectives, the characterization of the business environment may tolerate some inaccuracies (e.g. minor imprecisions in location or errors in business names). Furthermore, if the number of false negatives (FNs) and false positives (FPs) is balanced within a given area, one could argue that the database still provides a "fair" representation of existing resources in this area. Yet, traditional validation measures do not relax matching criteria, and treat FNs and FPs independently. Through the field validation of food businesses found in a Canadian database, this paper proposes alternative criteria for validity. Field validation of the 2010 Enhanced Points of Interest (EPOI) database (DMTI Spatial®) was performed in 2011 in 12 census tracts (CTs) in Montreal, Canada. Some 410 food outlets were extracted from the database and 484 were observed in the field. First, traditional measures of sensitivity and positive predictive value (PPV) accounting for every single mismatch between the field and the database were computed. Second, relaxed measures of sensitivity and PPV that tolerate mismatches in business names or slight imprecisions in location were assessed. A novel measure of representativity that further allows for compensation between FNs and FPs within the same business category and area was proposed. Representativity was computed at CT level as ((TPs +|FPs-FNs|)/(TPs+FNs)), with TPs meaning true positives, and |FPs-FNs| being the absolute value of the difference between the number of FNs and the number of FPs within each outlet category. The EPOI database had a "moderate" capacity to detect an outlet present in the field (sensitivity: 54.5%) or to list only the outlets that actually existed in the field (PPV: 64.4%). Relaxed measures of sensitivity and PPV

  14. Numerical simulation and geometry optimization of hot-gas mixing in lower plenum of high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Wang Hang; Wang Jie; Laurien, E.

    2010-01-01

    The lower plenum in high temperature gas-cooled reactor was designed to mix the gas of different temperatures from the reactor core. Previous researches suggest the current geometry of the lower plenum to be improved for better mixing capability and lower pressure drop. In the presented work, a series of varied geometries were investigated with numerical simulation way. The choice of appropriate mesh type and size used in the geometry variation was discussed with the reference of experimental data. The original thin ribs in the current design were merged into thicker ones, and a junction located at the starting end of the outlet pipe was introduced. After comparing several potential optimization methods, an improved geometry was selected with the merged ribs increasing the pre-defined mixing coefficient and the junction reducing the pressure drop. Future work was discussed based on the simulation of real reactor case. The work shows a direction for design improvements of the lower plenum geometry. (authors)

  15. Five years of health promoting work with bottle shops on the Central Coast of NSW Australia. How can we best ensure outlets check ID?

    Science.gov (United States)

    Bauer, Lyndon; Smith, Jeff; Kajons, Nicole; Tutt, Doug

    2018-04-24

    Australian surveys indicate that a large proportion of packaged liquor outlets do not check identification for young people before selling alcohol to them. There are a substantial number of presentations to Emergency Departments from young people aged 15 to 17 years. This subgroup is second only to those aged 18 to 24 years. In the 15- to 17-year-old age group, supply from direct purchase or underage friends, who have purchased alcohol, represents substantial sources of alcohol that is more likely to be consumed without parental supervision. Teenagers 18-19 years of age approached a randomly selected sample of bottle shops, on the NSW Central Coast Region, to attempt to purchase alcohol without producing identification (ID). Legally we are unable to test with teens under the age of 18. If outlets do not check ID for customers 18 or 19 years of age, we propose they might not check identification for 15- to 17-year-olds. A raft of local interventions was employed over four-survey periods to attempt to reduce selling rates. The lowest alcohol sales without ID occurred in 2015 when NSW Liquor and Gaming successfully prosecuted a Central Coast outlet for an underage sale. The rate of alcohol sales without checking ID each year was as follows: 2012-43.8%, 2014-37.55%, 2015-21.5% and 2016-45%. Alcohol sales to young customers without checking ID are common, widespread and seemingly resistant to non-punitive interventions. The NSW Liquor Act could be modified to allow compliance testing and much more practical enforcement. While Central Coast bottle shops have a better record than other Australian areas showing some improvements with our non-punitive industry education interventions, the results need to improve substantially to stifle primary supply. © 2018 Australian Health Promotion Association.

  16. Fluid flow distribution optimization for minimizing the peak temperature of a tubular solar receiver

    International Nuclear Information System (INIS)

    Wei, Min; Fan, Yilin; Luo, Lingai; Flamant, Gilles

    2015-01-01

    High temperature solar receiver is a core component of solar thermal power plants. However, non-uniform solar irradiation on the receiver walls and flow maldistribution of heat transfer fluid inside the tubes may cause the excessive peak temperature, consequently leading to the reduced lifetime. This paper presents an original CFD (computational fluid dynamics)-based evolutionary algorithm to determine the optimal fluid distribution in a tubular solar receiver for the minimization of its peak temperature. A pressurized-air solar receiver comprising of 45 parallel tubes subjected to a Gaussian-shape net heat flux absorbed by the receiver is used for study. Two optimality criteria are used for the algorithm: identical outlet fluid temperatures and identical temperatures on the centerline of the heated surface. The influences of different filling materials and thermal contact resistances on the optimal fluid distribution and on the peak temperature reduction are also evaluated and discussed. Results show that the fluid distribution optimization using the algorithm could minimize the peak temperature of the receiver under the optimality criterion of identical temperatures on the centerline. Different shapes of optimal fluid distribution are determined for various filling materials. Cheap material with low thermal conductivity can also meet the peak temperature threshold through optimizing the fluid distribution. - Highlights: • A 3D pressurized-air solar receiver based on the tube-in-matrix concept is studied. • An original evolutionary algorithm is developed for fluid distribution optimization. • A new optimality criterion is proposed for minimizing the receiver peak temperature. • Different optimal fluid distributions are determined for various filling materials. • Filling material with high thermal conductivity is more favorable in practical use.

  17. Diagnostic value of urodynamic bladder outlet obstruction to select patients for transurethral surgery of the prostate: Systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Myong Kim

    Full Text Available To investigate the diagnostic value of urodynamic bladder outlet obstruction (BOO in the selection of patients for transurethral surgery of the prostate.We systematically searched online PubMed, Embase, and Cochrane Library databases from January 1989 to June 2014.A total of 19 articles met the eligibility criteria for this systematic review. The eligible studies included a total of 2321 patients with a median number of 92 patients per study (range: 12-437. Of the 19 studies, 15 conducted conventional transurethral prostatectomy (TURP, and 7 used other or multiple modalities. In urodynamic bladder outlet obstruction (BOO positive patients, the pooled mean difference (MD was significant for better improvement of the International Prostate Symptom Score (IPSS (pooled MD, 3.48; 95% confidence interval [CI], 1.72-5.24; p < 0.01; studies, 16; participants, 1726, quality of life score (QoL (pooled MD, 0.56; 95% CI, 0.14-1.02; p = 0.010; studies, 9; participants, 1052, maximal flow rate (Qmax (pooled MD, 3.86; 95% CI, 2.17-5.54; p < 0.01; studies, 17; participants, 1852, and post-void residual volume (PVR (pooled MD, 32.46; 95% CI, 23.34-41.58; p < 0.01; studies, 10; participants, 1219 compared with that in non-BOO patients. Some comparisons showed between-study heterogeneity despite the strict selection criteria of the included studies. However, there was no clear evidence of publication bias in this meta-analysis.Our meta-analysis results showed a significant association between urodynamic BOO and better improvements in all treatment outcome parameters. Preoperative UDS may add insight into postoperative outcomes after surgical treatment of benign prostatic hyperplasia.

  18. Co-occurrence of outlet impingement syndrome of the shoulder and restricted range of motion in the thoracic spine - a prospective study with ultrasound-based motion analysis

    Directory of Open Access Journals (Sweden)

    Fuchs-Winkelmann Susanne

    2010-06-01

    Full Text Available Abstract Background Shoulder complaints, and especially the outlet-impingement syndrome, are a common condition. Among other things, poor posture has been discussed as a cause. A correlation between impingement syndrome and restricted mobility of the thoracic spine (T has been described earlier, but there has been no motion analysis of the thoracic spine to show these correlations. In the present prospective study, we intended to find out whether there is a significant difference in the thoracic sagittal range of motion (ROM between patients with a shoulder outlet impingement syndrome and a group of patients who had no shoulder pathology. Secondly, we wanted to clarify whether Ott's sign correlates with ultrasound topometric measurements. Methods Two sex- and age-matched groups (2 × n = 39 underwent a clinical and an ultrasound topometric examination. The postures examined were sitting up straight, sitting in maximal flexion and sitting in maximal extension. The disabilities of the arm, shoulder and hand (DASH score (obtained by means of a self-assessment questionnaire and the Constant score were calculated. Lengthening and shortening of the dorsal projections of the spine in functional positions was measured by tape with Ott's sign. Results On examination of the thoracic kyphosis in the erect seated posture there were no significant differences between the two groups (p = 0.66. With ultrasound topometric measurement it was possible to show a significantly restricted segmental mobility of the thoracic spine in the study group compared with the control group (p = 0.01. An in-depth look at the mobility of the subsegments T1-4, T5-8 and T9-12 revealed that differences between the groups in the mobility in the lower two sections of the thoracic spine were significant (T5-8: p = 0.03; T9-12: p = 0.02. The study group had an average Constant score of 35.1 points and the control group, 85.5 (p Conclusion The mobility of the thoracic spine should

  19. Evaluation of in-core neutron flux and temperature field measurements during the second period of power commissioning of the KS-150 reactor

    International Nuclear Information System (INIS)

    Rana, S.B.; Pecho, J.

    1975-01-01

    The in-core flux mapping system in the KS-150 reactor using mapping fuel elements with self-powered detectors is described. Experimental data evaluation using the Fourier analysis and determination of important operation parameters from the detectors and temperature field distribution using thermocouples for measuring coolant outlet temperatures and fuel temperatures are given. The DPZ-1 detectors used, mapping fuel elements and the method of signal registration are described. The results of operation of mapping fuel elements during the 2nd period of the KS-150 reactor commissioning are given. (author)

  20. Coolant mixing in the LMFBR outlet plenum

    International Nuclear Information System (INIS)

    Chen, Y.B.; Golay, M.W.

    1977-06-01

    Small scale experiments involving water flows are used to provide mean flow and turbulence field data for LMFBR outlet plenum flows. Measurements are performed at Reynolds Number (Re) values of 33000 and 70000 in a 1/15-scale FFTF geometry and at Re = 35000 in a 3/80-scale CRBR geometry. The experimental behavior is predicted using two different turbulence model computer programs, TEACH-T and VARR-II. It is found that the qualitative nature of the flow field within the plenum depends strongly upon the distribution of the mean inlet velocity field, upon the degree of inlet turbulence, and upon the turbulence momentum exchange model used in the calculations. It is found in the FFTF geometry that the TEACH-T predictions are better than that of VARR-II, and in the CRBR geometry neither code provides a good prediction of the observed behavior. From the sensitivity analysis, it is found that the production and dissipation of turbulence are the dominant terms in the transport equations for turbulent kinetic energy and turbulent energy dissipation rate, and the diffusion terms are relatively small. From the same study a new set of empirical constants for the turbulence model is evolved for the prediction of plenum flows

  1. Relationships between past and present pesticide applications and pollution at a watershed outlet: The case of a horticultural catchment in Martinique, French West Indies.

    Science.gov (United States)

    Mottes, Charles; Lesueur Jannoyer, Magalie; Le Bail, Marianne; Guéné, Mathilde; Carles, Céline; Malézieux, Eric

    2017-10-01

    The understanding of factors affecting pesticide transfers to catchment outlet is still at a very early stage in tropical context, and especially on tropical volcanic context. We performed on-farm pesticide use surveys during 87 weeks and monitored pesticides in water weekly during 67 weeks at the outlet of a small catchment in Martinique. We identified three types of pollution. First, we showed long-term chronic pollution by chlordecone, diuron and metolachlor resulting from horticultural practices applied 5-20 years ago (quantification frequency higher than 80%). Second, we showed peak pollution. High amounts of propiconazole and fosthiazate applied at low frequencies caused river pollution peaks for weeks following a single application. Low amounts of diquat and diazinon applied at low frequencies also caused pollution peaks. The high amounts of glyphosate applied at high frequency resulted into pollution peaks by glyphosate and aminomethylphosphonic acid (AMPA) in 6 and 20% of the weeks. Any intensification of their uses will result in higher pollution levels. Third, relatively low amounts of glufosinate-ammonium, difenoconazol, spinosad and metaldehyde were applied at high frequencies. Unexpectedly, such pesticides remained barely detected (pollution of shallow aquifers alimenting surface water. We prove that to avoid the past errors and decrease the risk of long-term pollution of water resources, it is urgent to reduce or stop the use of pesticides with leaching potential by changing agricultural practices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Evaluation of thermal displacement behavior of high temperature piping system in power-up test of HTTR. No. 1 results up to 20 MW operation

    International Nuclear Information System (INIS)

    Hanawa, Satoshi; Kojima, Takao; Sumita, Junya; Tachibana, Yukio

    2002-03-01

    Temperature of the primary cooling system of the High Temperature Engineering Test Reactor, HTTR, becomes very high because the coolant temperature at the reactor outlet reaches 950degC, and 400degC at inlet of the reactor. Therefore, it is important to confirm the thermal displacement behavior of the high temperature piping system in the primary cooling system from the viewpoint of the structural integrity. Moreover, newly designed 3-dimensional floating support system is adopted to the cooling system, it is meaningful to verify the thermal displacement behavior of the piping system applied the 3-dimensional floating support system. In the power-up test (up to 20 MW operation), thermal displacement behavior of the high temperature piping system was measured. This paper describes the experimental and analytical results of thermal displacement characteristics of the high temperature piping system. The results showed that the resistance force induced from the supporting system effects to the thermal displacement behavior of cooling system, and the analytical results have a good agreement with the experimental results by optimizing the resistant force of the floating support system. Additionally, structural integrity at the 30 MW operation was confirmed by the analysis. (author)

  3. Simulation of the effects of Devils Lake outlet alternatives on future lake levels and water quality in the Sheyenne River and Red River of the North

    Science.gov (United States)

    Vecchia, Aldo V.

    2011-01-01

    Since 1992, Devils Lake in northeastern North Dakota has risen nearly 30 feet, destroying hundreds of homes, inundating thousands of acres of productive farmland, and costing more than $1 billion for road raises, levee construction, and other flood mitigation measures. In 2011, the lake level is expected to rise at least another 2 feet above the historical record set in 2010 (1,452.0 feet above the National Geodetic Vertical Datum of 1929), cresting less than 4 feet from the lake's natural spill elevation to the Sheyenne River (1,458.0 feet). In an effort to slow the rising lake and reduce the chance of an uncontrolled spill, the State of North Dakota is considering options to expand a previously constructed outlet from the west end of Devils Lake or construct a second outlet from East Devils Lake. Future outlet discharges from Devils Lake, when combined with downstream receiving waters, need to be in compliance with applicable Clean Water Act requirements. This study was completed by the U.S. Geological Survey, in cooperation with the North Dakota Department of Health Division of Water Quality, to evaluate the various outlet alternatives with respect to their effect on downstream water quality and their ability to control future lake levels.

  4. 'McDonalds and KFC, it's never going to happen': the challenges of working with food outlets to tackle the obesogenic environment.

    Science.gov (United States)

    Hanratty, Barbara; Milton, Beth; Ashton, Matthew; Whitehead, Margaret

    2012-12-01

    Food outlets may make an important contribution to an obesogenic environment. This study investigated barriers and facilitators to public health work with food outlets in disadvantaged areas. In-depth qualitative interviews with 36 directors, managers and public health service delivery staff in a coterminous primary care trust and local authority in northwest England. Data were analysed using the constant comparative method. Three interventions were available to engage with businesses; awards for premises that welcomed breastfeeding mothers or offered healthy menu options and local authority planning powers. Sensitivity to the potential conflict between activities that generate profit and those that promote health, led to compromises, such as awards for cafés that offer only one healthy option on an otherwise unhealthy menu. An absence of existing relationships with businesses and limited time were powerful disincentives to action, leading to greater engagement with public rather than private sector organizations. Hiring staff with commercial experience and incentives for businesses were identified as useful strategies, but seldom used. Encouraging food outlets to contribute to tackling the obesogenic environment is a major challenge for local public health teams that requires supportive national policies. Commitment to engage with the local public health service should be part of any national voluntary agreements with industry.

  5. Estimation of the Influence of Operational Factors on the Oxygen Content of the Turbine Condensate at the Outlet from the Condenser of Steam Turbine

    Directory of Open Access Journals (Sweden)

    Shempelev A. G.

    2017-08-01

    Full Text Available The aim of the article is to analyze the influence of different factors on the oxygen content in the condensate using the example of the condenser of the steam turbine unit T-110/120-130. For the first time, the authors of the article analyze in details how the basic parameters of the condenser's operation (the condenser heat load, the flow and temperature of the cooling water, the air inflow in the condenser, the condition of the heat exchange surface influence the oxygen content of the condensate. The authors come to the conclusion that with standard air inflow in the vacuum system, the equilibrium oxygen content, which corresponds to the norms in the condensate at the condenser outlet, is only possible in its operation modes when the steam flow to the condenser is more than 50% of the nominal flow and cooling water temperatures are equal to or greater than calculated for this type of condenser. The conclusions are confirmed by the experimental material. The results of the research are the basis for the development of measures aimed to increase the deaerating capacity of condensers depending on specific operating conditions.

  6. Numerical simulations of helium flow through prismatic fuel elements of very high temperature reactors

    International Nuclear Information System (INIS)

    Ribeiro, Felipe Lopes; Pinto, Joao Pedro C.T.A.

    2013-01-01

    The 4 th generation Very High Temperature Reactor (VHTR) most popular concept uses a graphite-moderated and helium cooled core with an outlet gas temperature of approximately 1000 deg C. The high output temperature allows the use of the process heat and the production of hydrogen through the thermochemical iodine-sulfur process as well as highly efficient electricity generation. There are two concepts of VHTR core: the prismatic block and the pebble bed core. The prismatic block core has two popular concepts for the fuel element: multihole and annular. In the multi-hole fuel element, prismatic graphite blocks contain cylindrical flow channels where the helium coolant flows removing heat from cylindrical fuel rods positioned in the graphite. In the other hand, the annular type fuel element has annular channels around the fuel. This paper shows the numerical evaluations of prismatic multi-hole and annular VHTR fuel elements and does a comparison between the results of these assembly reactors. In this study the analysis were performed using the CFD code ANSYS CFX 14.0. The simulations were made in 1/12 fuel element models. A numerical validation was performed through the energy balance, where the theoretical and the numerical generated heat were compared for each model. (author)

  7. Male bladder outlet obstruction : Time to re-evaluate the definition and reconsider our diagnostic pathway? ICI-RS 2015

    NARCIS (Netherlands)

    Rademakers, Kevin; Drake, Marcus J; Gammie, Andrew; Djurhuus, Jens C; Rosier, Peter F W M; Abrams, Paul; Harding, Christopher

    The diagnosis of bladder outlet obstruction (BOO) in the male is dependent on measurements of pressure and flow made during urodynamic studies. The procedure of urodynamics and the indices used to delineate BOO are well standardized largely as a result of the work of the International Continence

  8. Thoracic Outlet Syndrome Caused by Hydatid Cyst of the First Rib-Rare But Important

    OpenAIRE

    Levy Faber, Dan; Best, Lael-Anson; Militianu, Daniela; Ben Nun, Alon

    2010-01-01

    Hydatid cysts are usually located in the liver and lungs. Skeletal echinococcosis is relatively rare and that of the rib is exceptional. Less than 50 cases of costal echinococcosis have been reported in the literature so far. To our knowledge, only one case report of thoracic outlet syndrome due to echinococcal cyst in the first rib was described in 1995. Accurate pre-operative diagnosis is important but may be challenging in some cases. Reported here is a case of echinococcosis of the first ...

  9. Impact on water quality of land uses along Thamalakane-Boteti River: An outlet of the Okavango Delta

    Science.gov (United States)

    Masamba, Wellington R. L.; Mazvimavi, Dominic

    Botswana is a semiarid country and yet has one of the world’s famous wetlands: the Okavango Delta. The Thamalakane-Boteti River is one of the Delta’s outlets. The water quality of the Thamalakane-Boteti River was determined and related to its utilisation. The major land uses along the Thamalakane River within Maun are residential areas, lodges, hotels, and grazing by cattle and donkeys. The water is used as a source of water for livestock, wildlife in a game park, horticulture and domestic applications including drinking. The river is also used for fishing. To check whether these activities negatively impact on the water quality, pH, electrical conductivity, dissolved oxygen, temperature, total dissolved nitrogen and phosphorus, Faecal coliforms and Faecal streptococci and selected metals were determined from July 2005 to January 2006. The pH was near neutral except for the southern most sampling sites where values of up to 10.3 were determined. Dissolved oxygen varied from 2 mg/l to 8 mg/l. Sodium (range 0.6-3.2 mg/l), K (0.3-3.6 mg/l), Fe (1.6-6.9 mg/l) conductivity (56-430 μS/cm) and Mg (0.2-6.7 mg/l) increased with increased distance from the Delta, whereas lead showed a slight decline. Total dissolved phosphorus was low (up to 0.02 mg/l) whereas total dissolved nitrogen was in the range 0.08-1.5 mg/l. Faecal coliform (range 0-48 CFU/100 ml) and Faecal streptococci (40-260 CFU/100 ml) were low for open waters with multiple uses. The results indicate that there is possibility of pollution with organic matter and nitrogen. It is recommended that more monitoring of water quality needs to be done and the sources of pollution identified.

  10. Transient analysis of carbon monoxide transport phenomena and adsorption kinetics in HT-PEMFC during dynamic current extraction

    International Nuclear Information System (INIS)

    Raj, Kamal Abdul Rasheedj; Chan, Siew Hwa

    2015-01-01

    Highlights: • Increasing the fuel cell temperature reduces outlet CO concentration. • Increasing the CO inlet (initial) concentration increases outlet CO concentration. • Increasing current density step and dwell time increases outlet CO concentration. • Increasing in the CL and GDL porosities reduces outlet CO concentration. - Abstract: This paper investigates the transport phenomena of carbon monoxide (CO) and adsorption kinetics, in a high-temperature proton exchange membrane fuel cell (HT-PEMFC) during step-wise current extraction (step-change in current extraction). Step-wise current extraction is a common process done to accommodate a sudden power surge during an operation. Since HT-PEMFCs are capable of handling high impurity of CO, hydrogen fuel that is contaminated with trace amount of CO is usually considered for commercial benefits. Thus, a transient three-dimensional isothermal anodic electro-kinetic numerical model is developed to determine the effect of operating parameters such as fuel cell temperature, CO inlet (initial) concentration, step-change of current density and dwell time on the transport phenomena of CO and adsorption kinetics. In addition, geometrical factors such as the catalyst layer (CL) and gas diffusion layer (GDL) porosity are also varied as well. The results show that the above-mentioned operating parameters can affect the maximum CO concentration at the CL, especially at the outlet of the channel. Specifically, a reduction of fuel cell temperature can significantly increase the CO concentration near the outlet, while increasing CO inlet (initial) concentration, step-change amplitude of current density and current density dwell time can cause an increase in CO concentration at the outlet, albeit to different extent. In addition, the increase in the porosity of CL and GDL, results in the reduction of the maximum CO concentration at the outlet, albeit to different extent. In addition, the CO and hydrogen surface coverage

  11. Numerical investigation of flow instability in parallel channels with supercritical water

    International Nuclear Information System (INIS)

    Shitsi, Edward; Debrah, Seth Kofi; Agbodemegbe, Vincent Yao; Ampomah-Amoako, Emmanuel

    2017-01-01

    Highlights: •Supercritical flow instability in parallel channels is investigated. •Flow dynamics and heat transfer characteristics are analyzed. •Mass flow rate, pressure, heating power, and axial power shape have significant effects on flow instability. •Numerical results are validated with experimental results. -- Abstract: SCWR is one of the selected Gen IV reactors purposely for electricity generation in the near future. It is a promising technology with higher efficiency compared to current LWRs but without the challenges of heat transfer and its associated flow instability. Supercritical flow instability is mainly caused by sharp change in the coolant properties around the pseudo-critical point of the working fluid and research into this phenomenon is needed to address concerns of flow instability at supercritical pressures. Flow instability in parallel channels at supercritical pressures is investigated in this paper using a three dimensional (3D) numerical tool (STAR-CCM+). The dynamics characteristics such as amplitude and period of out-of-phase inlet mass flow oscillation at the heated channel inlet, and heat transfer characteristic such as maximum outlet temperature of the heated channel outlet temperature oscillation are discussed. Influences of system parameters such as axial power shape, pressure, mass flow rate, and gravity are discussed based on the obtained mass flow and temperature oscillations. The results show that the system parameters have significant effect on the amplitude of the mass flow oscillation and maximum temperature of the heated outlet temperature oscillation but have little effect on the period of the mass flow oscillation. The amplitude of mass flow oscillation and maximum temperature of the heated channel outlet temperature oscillation increase with heating power. The numerical results when compared to experiment data show that the 3D numerical tool (STAR-CCM+) could capture dynamics and heat transfer characteristics of

  12. Sensitivity analysis and thermoeconomic comparison of ORCs (organic Rankine cycles) for low temperature waste heat recovery

    International Nuclear Information System (INIS)

    Feng, Yongqiang; Zhang, Yaning; Li, Bingxi; Yang, Jinfu; Shi, Yang

    2015-01-01

    The sensitivity analysis for low temperature ORCs (organic Rankine cycles), as well as the thermoeconomic comparison between the basic ORC and regenerative ORC using Non-dominated sorting genetic algorithm-II (NSGA-II), are conducted in this paper. The derivatives of five system parameters on system performance are used to evaluate the parametric sensitiveness. The exergy efficiency and the APR (heat exchanger area per unit net power output) are selected as the objective functions for multi-objective optimization using R123 under the low temperature heat source of 423 K. The Pareto frontier solution with bi-objective for maximizing exergy efficiency and minimizing APR is obtained and compared with the corresponding single-objective solutions. The results indicate that the prior consideration of improving thermal efficiency and exergy efficiency is to increase the evaporator outlet temperature. A fitting curve can be yielded from the Pareto frontier between the thermodynamic performance and economic factor. The optimum exergy efficiency and APR of the regenerative ORC obtained from the Pareto-optimal solution are 59.93% and 3.07 m 2 /kW, which are 8.10% higher and 15.89% lower than that of the basic ORC, respectively. The Pareto optimization compromises the thermodynamic performance and economic factor, therefore being more suitable for decision making. - Highlights: • The sensitivity analysis of the basic ORC is conducted. • The Pareto-optimal solution is compared with the single-objective solutions. • Evaporator outlet temperature should be preferentially considered. • 8.10% higher exergy efficiency and 15.89% lower APR for the regenerative ORC

  13. The position of the left and right ventricular outlets during septation. A comparison of chicken and rat development

    NARCIS (Netherlands)

    Wagenaar, J. A.; Lamers, W. H.; Los, J. A.

    1986-01-01

    A comparative study was made of the relative position of the outflow tracts of chicken and rat hearts with respect to the ventricles during septation. For this purpose the position of the left and right ventricular outlet including the aortic and pulmonary valve primordia and the left and right

  14. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects.

    Science.gov (United States)

    Åsberg, Dennis; Samuelsson, Jörgen; Leśko, Marek; Cavazzini, Alberto; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2015-07-03

    The importance of the generated temperature and pressure gradients in ultra-high-pressure liquid chromatography (UHPLC) are investigated and compared to high-pressure liquid chromatography (HPLC). The drug Omeprazole, together with three other model compounds (with different chemical characteristics, namely uncharged, positively and negatively charged) were used. Calculations of the complete temperature profile in the column at UHPLC conditions showed, in our experiments, a temperature difference between the inlet and outlet of 16 °C and a difference of 2 °C between the column center and the wall. Through van't Hoff plots, this information was used to single out the decrease in retention factor (k) solely due to the temperature gradient. The uncharged solute was least affected by temperature with a decrease in k of about 5% while for charged solutes the effect was more pronounced, with k decreases up to 14%. A pressure increase of 500 bar gave roughly 5% increase in k for the uncharged solute, while omeprazole and the other two charged solutes gave about 25, 20 and 15% increases in k, respectively. The stochastic model of chromatography was applied to estimate the dependence of the average number of adsorption/desorption events (n) and the average time spent by a molecule in the stationary phase (τs) on temperature and pressure on peak shape for the tailing, basic solute. Increasing the temperature yielded an increase in n and decrease in τs which resulted in less skew at high temperatures. With increasing pressure, the stochastic modeling gave interesting results for the basic solute showing that the skew of the peak increased with pressure. The conclusion is that pressure effects are more pronounced for both retention and peak shape than the temperature effects for the polar or charged compounds in our study. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Potentialities of high temperature reactors (HTR)

    International Nuclear Information System (INIS)

    Hittner, D.

    2001-01-01

    This articles reviews the assets of high temperature reactors concerning the amount of radioactive wastes produced. 2 factors favors HTR-type reactors: high thermal efficiency and high burn-ups. The high thermal efficiency is due to the high temperature of the coolant, in the case of the GT-MHR project (a cooperation between General Atomic, Minatom, Framatome, and Fuji Electric) designed to burn Russian military plutonium, the expected yield will be 47% with an outlet helium temperature of 850 Celsius degrees. The high temperature of the coolant favors a lot of uses of the heat generated by the reactor: urban heating, chemical processes, or desalination of sea water.The use of a HTR-type reactor in a co-generating way can value up to 90% of the energy produced. The high burn-up is due to the technology of HTR-type fuel that is based on encapsulation of fuel balls with heat-resisting materials. The nuclear fuel of Fort-Saint-Vrain unit (Usa) has reached values of burn-ups from 100.000 to 120.000 MWj/t. It is shown that the quantity of unloaded spent fuel can be divided by 4 for the same amount of electricity produced, in the case of the GT-MHR project in comparison with a light water reactor. (A.C.)

  16. MRI findings in thoracic outlet syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Aralasmak, Ayse; Sharifov, Rasul; Kilicarslan, Rukiye; Alkan, Alpay [Bezmialem Vakif University, Department of Radiology, Fatih/Istanbul (Turkey); Cevikol, Can; Karaali, Kamil; Senol, Utku [Akdeniz University, Department of Radiology, Antalya (Turkey)

    2012-11-15

    We discuss MRI findings in patients with thoracic outlet syndrome (TOS). A total of 100 neurovascular bundles were evaluated in the interscalene triangle (IS), costoclavicular (CC), and retropectoralis minor (RPM) spaces. To exclude neurogenic abnormality, MRIs of the cervical spine and brachial plexus (BPL) were obtained in neutral. To exclude compression on neurovascular bundles, sagittal T1W images were obtained vertical to the longitudinal axis of BPL from spinal cord to the medial part of the humerus, in abduction and neutral. To exclude vascular TOS, MR angiography (MRA) and venography (MRV) of the subclavian artery (SA) and vein (SV) in abduction were obtained. If there is compression on the vessels, MRA and MRV of the subclavian vessels were repeated in neutral. Seventy-one neurovascular bundles were found to be abnormal: 16 arterial-venous-neurogenic, 20 neurogenic, 1 arterial, 15 venous, 8 arterial-venous, 3 arterial-neurogenic, and 8 venous-neurogenic TOS. Overall, neurogenic TOS was noted in 69%, venous TOS in 66%, and arterial TOS in 39%. The neurovascular bundle was most commonly compressed in the CC, mostly secondary to position, and very rarely compressed in the RPM. The cause of TOS was congenital bone variations in 36%, congenital fibromuscular anomalies in 11%, and position in 53%. In 5%, there was unilateral brachial plexitis in addition to compression of the neurovascular bundle. Severe cervical spondylosis was noted in 14%, contributing to TOS symptoms. For evaluation of patients with TOS, visualization of the brachial plexus and cervical spine and dynamic evaluation of neurovascular bundles in the cervicothoracobrachial region are mandatory. (orig.)

  17. Effects of Gravity and Inlet/Outlet Location on a Two-Phase Cocurrent Imbibition in Porous Media

    Directory of Open Access Journals (Sweden)

    M. F. El-Amin

    2011-01-01

    Full Text Available We introduce 2D numerical investigations of the problem of gravity and inlet/outlet location effects of water-oil two-phase cocurrent imbibition in a porous medium. Three different cases of side-, top-, and bottom-inlet location are considered. Two-dimensional computations are carried out using the finite element method. Intensive comparisons are done between considering and neglecting gravity effect on water saturation, pressures of water and oil as well as water velocity. Results are introduced either in curves or as 2D visualization graphs. The results indicate that the buoyancy effects due to gravity force take place depending on inlet location. So, the buoyancy force in the momentum equations of the co-current imbibition model cannot be neglected as done by several previous studies. Also, we note that the 2D zero gravity model has a uniform flow and may be represented as 1D flow unlike the 2D nonzero gravity model showing a nonuniform flow.

  18. Effects of gravity and inlet/outlet location on a two-phase cocurrent imbibition in porous media

    KAUST Repository

    El-Amin, Mohamed

    2011-01-01

    We introduce 2D numerical investigations of the problem of gravity and inlet/outlet location effects of water-oil two-phase cocurrent imbibition in a porous medium. Three different cases of side-, top-, and bottom-inlet location are considered. Two-dimensional computations are carried out using the finite element method. Intensive comparisons are done between considering and neglecting gravity effect on water saturation, pressures of water and oil as well as water velocity. Results are introduced either in curves or as 2D visualization graphs. The results indicate that the buoyancy effects due to gravity force take place depending on inlet location. So, the buoyancy force in the momentum equations of the co-current imbibition model cannot be neglected as done by several previous studies. Also, we note that the 2D zero gravity model has a uniform flow and may be represented as 1D flow unlike the 2D nonzero gravity model showing a nonuniform flow. Copyright 2011 M. F. El-Amin and Shuyu Sun.

  19. Primary duodenal tuberculosis presenting as gastric-outlet obstruction: Its diagnosis

    Directory of Open Access Journals (Sweden)

    Vijai Datta Upadhyaya

    2013-01-01

    Full Text Available Introduction: Gastrointestinal tuberculosis often involves the ileocecal region. Duodenal and gastric tuberculosis found in only 1% of patients suffering from pulmonary tuberculosis with associated HIV infection in non-endemic areas. Duodenal obstruction due to tuberculosis is very rare and needs high index of suspicions for diagnosis. Mostly this entity is suspected on intraoperative findings. In this manuscript we emphasized on ways and means for establishing histopathological diagnosis before starting anti-tubercular treatment in such cases. Method and Material: All patients of suspected gastroduodenal tuberculosis presented with feature of gastric-outlet obstruction managed during Jan 2009 to June 2011 were included in the study. After proper evaluation (routine hematological and biochemical examination, microbiological examination, serological and endoscopic evaluation exploratory laparotomy was done and if there is no mesenteric lymphadenopathy or it is not safe to take biopsy form the diseased duodenum, multiple FNAC were taken from the diseased portion for histopathological and microbiological diagnosis. Result: A total of five patients were treated during this period. The most common presentation was vomiting followed by failure to thrive and weight loss; two patients had abdominal pain. Biopsy of mesenteric lymph node was possible in two cases. FNAC from diseases portion was taken in all cases. FNAC showed granulomas in four cases. Cases where even FNAC finding was non-conclusive on HPE/Microbiology was not subjected to antitubercular drug. Conclusion: Multiple intra-operative FNAC may be taken from the diseased portion of the duodenum to establish the histopathological diagnosis if diagnosis is not established by any other mean.

  20. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation

    International Nuclear Information System (INIS)

    Mastora, I.; Remy-Jardin, M.; Remy, J.; Suess, C.; Scherf, C.; Guillot, J.P.

    2001-01-01

    The aim of this study was to evaluate dose reduction in spiral CT angiography of the thoracic outlet by on-line tube-current control. Prospectively, 114 patients undergoing spiral CT angiography of the subclavian artery for thoracic outlet arterial syndromes were evaluated with and without tube-current modulation at the same session (scanning parameters for the two successive angiograms, one in the neutral position and one after the postural maneuver): 140 kV; 206 mA; scan time 0.75 s; collimation 3 mm; pitch = (1). The dose reduction system was applied in the neutral position in the first 92 consecutive patients and after postural maneuver in the remaining 22 consecutive patients. Dose reduction and image quality were analyzed in the overall study group (group 1; n = 114). The influence of the arm position was assessed in 44 of the 114 patients (group 2), matched by the transverse diameter of the upper thorax. The mean dose reduction was 33 % in group 1 (range 22-40 %) and 34 % in group 2 (range 26-40 %). In group 2 the only difference in image quality was a significantly higher frequency of graininess on low-dose scans compared with reference scans whatever the patient's arm position, graded as minimal in 38 of the 44 patients (86 %). When the low-dose technique was applied after postural maneuver in group 2: (a) the mean dose reduction was significantly higher (35 vs 32 % in the neutral position; p = 0.006); (b) graininess was less frequent (82 vs 91 % in the neutral position); and (c) the percentage of graininess graded as minimal was significantly higher (83 vs 70 % in the neutral position; p = 0.2027). On-line tube-current modulation enables dose reduction on high-quality, diagnostic spiral CT angiograms of the thoracic outlet and should be applied during data acquisition in the neutral position and after postural maneuver for optimal use. (orig.)