WorldWideScience

Sample records for osl optical stimulated

  1. Optical stimulated luminescence (OSL) dating

    International Nuclear Information System (INIS)

    Banerjee, D.

    1999-01-01

    Since the pioneering work by Huntley et al. (1985), optical dating is being increasingly recognised as an important technique for establishing a time frame of deposition of sediments (Aitken, 1998). Optical dating differs from thermoluminescence (TL) dating in that visible/infrared light from lasers or LEDs (light-emitting-diodes) is used as a means of stimulation, in contrast to thermal stimulation. It has several advantages over TL dating: (i) the resetting of the OSL (optically stimulated luminescence) clock is more effective than that of TL clock; for sediments transported under water or in other situations where the sediment grains have undergone inhomogeneous bleaching, this property ensures that ages based on optical dating are generally more reliable than TL ages, (ii) the optical dating technique is non-destructive, and multiple readouts of the optical signal is possible; this feature has resulted in the development of single-aliquot and single-grain protocols (Murray and Wintle, 1999; Banerjee et al. 1999), (iii) the sample is not heated as in TL; thus, spurious luminescence is avoided and there is a significant reduction in blackbody radiation. Dating of materials which change phase on heating is also practical, and finally, (iv) thermal quenching of luminescence is negligible, allowing accurate estimation of kinetic parameters using standard techniques and providing access to deep OSL traps. This characteristic may be helpful in extending the limits of optical dating beyond the last 150 ka from a global point of view

  2. OSL at elevated temperatures: Towards the simultaneous thermal and optical stimulation

    International Nuclear Information System (INIS)

    Polymeris, George S.

    2015-01-01

    In routine OSL dating measurements, a preheat procedure at high temperatures is used to empty the shallow traps. Thus no contribution from shallow traps was expected as each OSL measurement is subsequently performed at moderately high temperatures, around 110–125 °C. The present work attempts to consider the OSL measurements performed at elevated temperatures without any previous preheat as a case of simultaneous thermal and optical stimulation of the same trap. Towards this direction, a set of proposed equations is derived for all three different cases of optical stimulation modes, namely CW-OSL, LM-OSL as well as PS-LM-OSL. According to these equations, indicative features of thermally activated OSL processes are expected, such as the steepening of CW-OSL decay curves as either stimulation temperature or intensity increases, as well as the shifting of the stimulation time of the maximum intensity for both LM-OSL and PS-LM-OSL curves towards shorter times with increasing temperatures. Experimentally, specific measurement sequences after varying stimulation temperature and/or intensity were applied in order to estimate the values of associated trap parameters, such as activation energy and photo-ionization cross-section. Experimental OSL data from a milky natural quartz sample stand in good agreement of these theoretical considerations in the case of 110 °C TL peak and the intense OSL component C 2 monitored at RT. - Highlights: • OSL at elevated temperatures without preheat results from two simultaneous stimulation modes. • Equations were derived assuming of linear superposition of two stimulation modes. • Data for 110 °C TL peak and OSL C 2 at RT stand in agreement with these equations. • Results verify the linear superposition of the two stimulation modes

  3. Study of optically stimulated luminescence (OSL) for radiation detection. Application to an optical fibre γ-radiation sensor

    International Nuclear Information System (INIS)

    Roy, O.

    1998-01-01

    This work shows up the usefulness of the Optically Stimulated Luminescence (OSL) to resolve radioprotection problems. We study the use of OSL as a gamma dosimetric technique with respect to the ALARA's concept (As Low As Reasonably Achievable). A new approach based on optical fibers and luminescent materials showing OSL properties (closely related to Thermoluminescence phenomena) is presented in order to improve the remote real time dosimetry monitoring. Like thermoluminescent materials (TLD), OSL materials can trap charges under an irradiation (UV, X, γ,...). Instead of heating, the charges trapped are released by light stimulation and produce a visible luminescence which amount is proportional to trap the 'data stored' left by irradiation, enabling the dose measurement. The OSL phenomenon offers the same advantages as TLD plus the interesting possibility of a remote optical stimulation. The end-user objective deals with the development of a γ-radiation Optical FIber Sensor (OFS) for dose measurement which can offer new functionalities based on OSL materials coupled with an optical fiber. Rare earth doped Alkaline Earth Sulphides (AES), BAFX:EU 2+ (X = Cl, Br, I) and halogen alkaline have been studied (crystalline form, synthesis techniques, influence of dopants and color centers). Their characteristics are presented and extensively discussed. A specific experimental set-up to characterise various OSL phosphors has been developed. It allows the study of sensitivity, linearity, time decay behaviour of OSL signal and zeroing time. A joint study of OSL and TL has shown the technical limitations as well as the thermal fading and the origin of the long zeroing time. An Optical Fiber Sensor (OFS) based on OSL and using MgS:Sm has been developed for practical applications on nuclear fields. Its specifications are presented and discussed, moreover improvements are proposed. (author)

  4. Optically stimulated luminescence (OSL) from Ag-doped Li2B4O7 crystals

    International Nuclear Information System (INIS)

    Kananen, B.E.; Maniego, E.S.; Golden, E.M.; Giles, N.C.; McClory, J.W.; Adamiv, V.T.; Burak, Ya.V.; Halliburton, L.E.

    2016-01-01

    Optically stimulated luminescence (CW-OSL) is observed from Ag-doped lithium tetraborate (Li 2 B 4 O 7 ) crystals. Photoluminescence, optical absorption, and electron paramagnetic resonance (EPR) are used to identify the defects participating in the OSL process. As-grown crystals have Ag + ions substituting for Li + ions. They also have Ag + ions occupying interstitial sites. During a room-temperature exposure to ionizing radiation, holes are trapped at the Ag + ions that replace Li + ions and electrons are trapped at the interstitial Ag + ions, i.e., the radiation forms Ag 2+ (4d 9 ) ions and Ag 0 (4d 10 5s 1 ) atoms. These Ag 2+ and Ag 0 centers have characteristic EPR spectra. The Ag 0 centers also have a broad optical absorption band peaking near 370 nm. An OSL response is observed when the stimulation wavelength overlaps this absorption band. Specifically, stimulation with 400 nm light produces an intense OSL response when emission is monitored near 270 nm. Electrons optically released from the Ag 0 centers recombine with holes trapped at Ag 2+ ions to produce the ultraviolet emission. The OSL response is progressively smaller as the stimulation light is moved to longer wavelengths (i.e., away from the 370 nm peak of the absorption band of the Ag 0 electron traps). Oxygen vacancies are also present in the Ag-doped Li 2 B 4 O 7 crystals, and their role in the OSL process as a secondary relatively short-lived electron trap is described.

  5. Gamma response characterizations of optically stimulated luminescence (OSL) affects personal dosimetry

    Science.gov (United States)

    Monthonwattana, S.; Esor, J.; Rungseesumran, T.; Intang, A.

    2017-06-01

    Optically Stimulated Luminescence (OSL) is the current technique of personal dosimetry changed by Nuclear Technology Service Center instead of Thermoluminescence dosimetry (TLD) because OSL has more advantages, such as repeat reading and elimination of heating process. In this study, OSL was used to test the gamma response characterizations. Detailed OSL investigation on personal dosimetry was carried out in the dose range of 0.2 - 3.0 mSv. The batch homogeneity was 7.66%. R2 value of the linear regression was 0.9997. The difference ratio of angular dependence at ± 60° was 8.7%. Fading of the reading was about 3%.

  6. Optically stimulated luminescence (OSL) of dental enamel for retrospective assessment of radiation exposure

    International Nuclear Information System (INIS)

    Yukihara, E.G.; Mittani, J.; McKeever, S.W.S.; Simon, S.L.

    2007-01-01

    This paper briefly reviews the optically stimulated luminescence (OSL) properties of dental enamel and discusses the potential and challenges of OSL for filling the technology gap in biodosimetry required for medical triage following a radiological/nuclear accident or terrorist event. The OSL technique uses light to stimulate a radiation-induced luminescence signal from materials previously exposed to ionizing radiation. This luminescence originates from radiation-induced defects in insulating crystals and is proportional to the absorbed dose of ionizing radiation. In our research conducted to date, we focused on fundamental investigations of the OSL properties of dental enamel using extracted teeth and tabletop OSL readers. The objective was to obtain information to support the development of the necessary instrumentation for retrospective dosimetry using dental enamel in laboratory, or for in situ and non-invasive accident dosimetry using dental enamel in emergency triage. An OSL signal from human dental enamel was detected using blue, green, or IR stimulation. Blue/green stimulation associated with UV emission detection seems to be the most appropriate combination in the sense that there is no signal from un-irradiated samples and the shape of the OSL decay is clear. Improvements in the minimum detection level were achieved by incorporating an ellipsoidal mirror in the OSL system to maximize light collection. Other possibilities to improve the sensitivity and research steps necessary to establish the feasibility of the technique for retrospective assessment of radiation exposure are also discussed

  7. Optically stimulated luminescence (OSL) from Ag-doped Li{sub 2}B{sub 4}O{sub 7} crystals

    Energy Technology Data Exchange (ETDEWEB)

    Kananen, B.E.; Maniego, E.S.; Golden, E.M.; Giles, N.C.; McClory, J.W. [Department of Engineering Physics, Air Force Institute of Technology, Wright-Patterson Air Force Base, OH 45433 (United States); Adamiv, V.T.; Burak, Ya.V. [Vlokh Institute of Physical Optics, Dragomanov 23, L’viv 79005 (Ukraine); Halliburton, L.E., E-mail: Larry.Halliburton@mail.wvu.edu [Department of Physics and Astronomy, West Virginia University, Morgantown, WV 26506 (United States)

    2016-09-15

    Optically stimulated luminescence (CW-OSL) is observed from Ag-doped lithium tetraborate (Li{sub 2}B{sub 4}O{sub 7}) crystals. Photoluminescence, optical absorption, and electron paramagnetic resonance (EPR) are used to identify the defects participating in the OSL process. As-grown crystals have Ag{sup +} ions substituting for Li{sup +} ions. They also have Ag{sup +} ions occupying interstitial sites. During a room-temperature exposure to ionizing radiation, holes are trapped at the Ag{sup +} ions that replace Li{sup +} ions and electrons are trapped at the interstitial Ag{sup +} ions, i.e., the radiation forms Ag{sup 2+} (4d{sup 9}) ions and Ag{sup 0} (4d{sup 10}5s{sup 1}) atoms. These Ag{sup 2+} and Ag{sup 0} centers have characteristic EPR spectra. The Ag{sup 0} centers also have a broad optical absorption band peaking near 370 nm. An OSL response is observed when the stimulation wavelength overlaps this absorption band. Specifically, stimulation with 400 nm light produces an intense OSL response when emission is monitored near 270 nm. Electrons optically released from the Ag{sup 0} centers recombine with holes trapped at Ag{sup 2+} ions to produce the ultraviolet emission. The OSL response is progressively smaller as the stimulation light is moved to longer wavelengths (i.e., away from the 370 nm peak of the absorption band of the Ag{sup 0} electron traps). Oxygen vacancies are also present in the Ag-doped Li{sub 2}B{sub 4}O{sub 7} crystals, and their role in the OSL process as a secondary relatively short-lived electron trap is described.

  8. Desiccants for retrospective dosimetry using optically stimulated luminescence (OSL)

    International Nuclear Information System (INIS)

    Geber-Bergstrand, Therése; Bernhardsson, Christian; Christiansson, Maria; Mattsson, Sören; Rääf, Christopher L.

    2015-01-01

    Optically stimulated luminescence (OSL) was used to test different kinds of desiccants for their potential use in retrospective dosimetry. Desiccants are used for the purpose of absorbing liquids and can be found in a number of items which may be found in the immediate environment of a person, including hand bags, drug packages, and the vehicles of rescue service teams. Any material exhibiting OSL properties suitable for retrospective dosimetry is a useful addition to the existing dosimetry system available in emergency preparedness. Eleven kinds of desiccants were investigated in order to obtain an overview of the fundamental OSL properties necessary for retrospective dosimetry. Measurements were made using a Risø TL/OSL reader and irradiations were achieved with the 90 Sr/ 90 Y source incorporated in the reader. Several of the desiccants exhibited promising properties as retrospective dosemeters. Some of the materials exhibited a strong as-received signal, i.e. without any laboratory irradiation, but the origin of this signal has not yet been established. The minimum detectable dose ranged from 8 to 450 mGy for ten of the materials and for one material (consisting of natural clay) the minimum detectable dose was 1.8 Gy. - Highlights: • Desiccants can be used as fortuitous dosemeters using OSL. • The minimum detectable dose for processed desiccants range from 8 to 450 mGy. • The minimum detectable dose for natural clay was 1.8 Gy

  9. Study of optically stimulated luminescence (OSL) for radiation detection. Application to an optical fibre {gamma}-radiation sensor; Etude de la luminescence stimulee optiquement (OSL) pour la detection de rayonnements: application a un capteur a fibre optique de rayonnement {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Roy, O. [CEA Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Electronique et d`Instrumentation Nucleaire]|[Paris-7 Univ., 75 (France)

    1998-12-31

    This work shows up the usefulness of the Optically Stimulated Luminescence (OSL) to resolve radioprotection problems. We study the use of OSL as a gamma dosimetric technique with respect to the ALARA`s concept (As Low As Reasonably Achievable). A new approach based on optical fibers and luminescent materials showing OSL properties (closely related to Thermoluminescence phenomena) is presented in order to improve the remote real time dosimetry monitoring. Like thermoluminescent materials (TLD), OSL materials can trap charges under an irradiation (UV, X, {gamma},...). Instead of heating, the charges trapped are released by light stimulation and produce a visible luminescence which amount is proportional to trap the `data stored` left by irradiation, enabling the dose measurement. The OSL phenomenon offers the same advantages as TLD plus the interesting possibility of a remote optical stimulation. The end-user objective deals with the development of a {gamma}-radiation Optical FIber Sensor (OFS) for dose measurement which can offer new functionalities based on OSL materials coupled with an optical fiber. Rare earth doped Alkaline Earth Sulphides (AES), BAFX:EU{sup 2+} (X = Cl, Br, I) and halogen alkaline have been studied (crystalline form, synthesis techniques, influence of dopants and color centers). Their characteristics are presented and extensively discussed. A specific experimental set-up to characterise various OSL phosphors has been developed. It allows the study of sensitivity, linearity, time decay behaviour of OSL signal and zeroing time. A joint study of OSL and TL has shown the technical limitations as well as the thermal fading and the origin of the long zeroing time. An Optical Fiber Sensor (OFS) based on OSL and using MgS:Sm has been developed for practical applications on nuclear fields. Its specifications are presented and discussed, moreover improvements are proposed. (author) 320 refs.

  10. Dosimetry in the multi kilo-Gray range using optically-stimulated luminescence (OSL) and thermally-transferred OSL from quartz

    International Nuclear Information System (INIS)

    Burbidge, C.I.; Cabo Verde, S.I.; Fernandes, A.C.; Prudencio, M.I.; Botelho, M.L.; Dias, M.I.; Cardoso, G.

    2011-01-01

    This study explores the potential for using photon-stimulated luminescence of quartz grains to retrospectively evaluate multi-kGy gamma radiation doses. Subsamples from two ceramic tiles were given 60 Co gamma doses of 1, 3, 5, 15 and 30 kGy (nominal), accompanied by PMMA dosimeters and quartz grains from a geological sample known to exhibit thermally-transferred optically-stimulated luminescence (TTOSL). Following gamma irradiation, quartz grains were prepared from each subsample. OSL and TTOSL signals were measured for different preheat temperatures, and following re-irradiation with beta doses designed to equal the nominal gamma doses. OSL responses to 10 Gy beta test doses were measured following each cycle of high dose irradiation. Gamma doses were predicted from the beta responses, to evaluate the effectiveness of retrospective dose evaluation for different signal integrals, preheat combinations, and dose intervals. The use of linear modulation limited maximum OSL signal levels to 1.5 x 10 6 cps without reducing detector sensitivity, for the measurement of smaller TTOSL signals. The dosimetric behaviour of the three samples differed significantly: the best results were obtained from the pre-prepared geological quartz. OSL signals evident at short stimulation times, which are conventionally used for dosimetry and dating, did not in general appear appropriate for dosimetry in the range of doses examined. They exhibited dose response characteristics that were highly preheat dependant and variable in form between samples, which contained rapidly saturating and/or non-monotonic components. Higher preheats, up to 300 o C, preferentially removed OSL and TTOSL signals evident at longer stimulation times: those that remained yielded growth in signal with dose to approximately 10 kGy, but the accuracy of retrospective dose determinations was variable. TTOSL signals evident at short stimulation times increased proportionally with dose when 300 o C preheats were used, up

  11. Optically stimulated luminescence (OSL) and some other luminescence images from granite slices exposed with radiations

    International Nuclear Information System (INIS)

    Hashimoto, T.; Notoya, S.; Ojima, T.; Hoteida, M.

    1995-01-01

    Optically stimulated luminescence (OSL) images of some X- and γ-irradiated granite slices were obtained using photon detection through a 570 nm bandpass filter with diode-laser excitation of 910 nm. Alternative photo-induced phosphorescence (PIP) images, which were colour photographed immediately after the sunlight exposure of slice samples, were also found to be helpful in the observation of the luminescence properties and to filter selection for OSL measurements. These OSL and PIP images were compared with some other colour luminescence images, including thermoluminescence images (TLCI) and after-glow images (AGCI). It was obvious that there exists a variety of coloured emissions derived mainly from feldspar constituents and these were found to be dependent on the geological history or metamorphism of the granites. (Author)

  12. Optically stimulated luminescence (OSL) as a chronometer for surface exposure dating

    DEFF Research Database (Denmark)

    Sohbati, Reza; Murray, Andrew S.; Chapot, Melissa S.

    2012-01-01

    We pioneer a technique of surface-exposure dating based upon the characteristic form of an optically stimulated luminescence (OSL) bleaching profile beneath a rock surface; this evolves as a function of depth and time. As a field illustration of this new method, the maximum age of a premier example...... exposure histories; one of these samples was exposed at the time of sampling and one was buried and no longer light exposed. A third sample is known to have been first exposed 80 years ago and was still exposed at the time of sampling. First, the OSL-depth profile of the known-age sample is modeled...... to estimate material-dependent and environmental parameters. These parameters are then used to fit the model to the corresponding data for the samples of unknown exposure history. From these fits we calculate that the buried sample was light exposed for similar to 700 years before burial and that the unburied...

  13. Characterization of an optically stimulated luminescence (OSL) material for thermal neutron detection: SrS:Ce,Sm,B

    International Nuclear Information System (INIS)

    Ravotti, Federico; Garcia, Pierre; Prevost, Hildegarde; Dusseau, Laurent; Lapraz, Dominique; Vaille, Jean-Roch; Benoit, David

    2008-01-01

    SrS:Ce,Sm exhibits some interesting phosphorescent and charge storage properties that are used in OSL (optically stimulated luminescence) radiation dosimetry. To enhance the thermal neutron sensitivity of this phosphor, a new material obtained by boron doping has been developed. This OSL, B material was analysed with respect to its optical and structural characteristics in order to study possible modifications induced by doping procedure. Optical study highlights a decrease in the material luminescence of about 40% with TL and OSL experiments. The emission spectrum remains the same after boron addition. This result is in agreement with the structural characterization analysis since the lattice parameters were not modified. 11B MAS NMR results indicate that boron atoms are present in the host lattice in form of BO4 groups. Consequences on dosimetry applications are discussed. The neutron response of the OSL, B irradiated in a nuclear reactor is linear up to a fluence of 5 x 1011 cm -2 and it is possible to separate the thermal neutron and gamma components. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  14. Optically stimulated luminescence (OSL) dating of quartzite cobbles from the Tapada do Montinho archaeological site (east-central Portugal)

    DEFF Research Database (Denmark)

    Sohbati, Reza; Murray, Andrew S.; Buylaert, Jan-Pieter

    2012-01-01

    The burial age of an alluvially deposited cobble pavement at the Tapada do Montinho archaeological site (east-central Portugal) is investigated using optically stimulated luminescence (OSL) dating. Measurements on the cobbles (quartzite clasts) were carried out on intact slices and large aliquots...

  15. Fiber optic based OSL set up for online and offline measurements of dose due to ionizing radiation

    International Nuclear Information System (INIS)

    Rawat, N.S.; Kulkarni, M.S.; Upadhyay, B.N.; Srikanth, G.; Bindra, K.S.; Oak, S.M.

    2016-01-01

    An optic-fiber dosimetry system based on optically stimulated luminescence (OSL) and radio-luminescence (RL) from Al_2O_3 : C single-crystal (detector) was designed and developed. The set up is intended to measure dose and dose rates at various radiological installations. The Al_2O_3:C single crystal (from Landaeur Inc. USA) was coupled to a fiber optic delivery system and OSL from the detector is stimulated via the optical fiber cable using light from a Nd:YAG laser. OSL and RL signals are later used to predict cumulative dose and dose rates using "6"0Co gamma source. (author)

  16. Pulse and integral optically stimulated luminescence (OSL). Similarities and dissimilarities to thermoluminescence (TL) dose dependence and dose-rate effects

    International Nuclear Information System (INIS)

    Chen, R.; Leung, P.L.

    2000-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence (Tl) are two possible methods to monitor the absorbed radiation in solid samples, and therefore are utilized for dosimetry. For this application, two properties are desirable, namely, linear dose dependence of the measured quantity and dose-rate independence. For Tl, different kinds of super linear dose dependence have been reported in the literature in different materials, and in some cases, dose-rate dependence has also been found. These have been explained as being the result of competition. In OSL, some recent works reported on super linear dose dependence in annealed samples. In the present work, we explain the possible occurrence of these phenomena in OSL by solving numerically the relevant rate equations governing the process during irradiation, relaxation and read-out (heating or light stimulation). The results show that for short pulse OSL, quadratic dose dependence can be expected when only one trapping state and one kind of recombination center are involved and when the excitation starts with empty traps and centers. With the short pulse OSL, the calculation also reveals a possible dose-rate effect. Under the same circumstances, the area under the OSL curve depends linearly on the dose. The dependence of the whole area under the OSL curve on the dose is shown to be super linear when a disconnected trapping state or radiationless center take part in the process. Also, dose-rate effect can be expected in these cases, although no experimental effect of this sort has been reported so far. In pulse OSL, the analogy is made between the measured intensity and the initial rise range of non-first order Tl, whereas for the total area OSL, there is a nearly full analogy with the dose behavior of the Tl maximum. (Author)

  17. LM-OSL signals from some insulators: an analysis of the dependency of the detrapping probability on stimulation light intensity

    DEFF Research Database (Denmark)

    Bulur, E.; Bøtter-Jensen, L.; Murray, A.S.

    2001-01-01

    Optically stimulated luminescence (OSL) signals from various insulators including quartz, Al2O3 : C, BeO and NaCl have been studied using the linear modulation OSL (LM-OSL) technique. LM-OSL is based on the linear increase of the stimulation light power from zero to a maximum during the measurement...... is not always correct. The initial decay rates of the blue (similar to 470 nm) light stimulated constant power OSL decay curves were examined to test the relation between the detrapping rates and the stimulation light intensity. In SiO2, Al2O3 : C and BeO a linear relation between the detrapping rates....... The resultant OSL curve initially increases and then decays after reaching a maximum, The analysis of LM-OSL data usually assumes a linear relationship between the detrapping rate and the stimulation light intensity. However, experiments carried out using various insulators have shown that this assumption...

  18. Assessing the completeness of optical resetting of quartz OSL in the natural environment

    International Nuclear Information System (INIS)

    Singarayer, J.S.; Bailey, R.M.; Ward, S.; Stokes, S.

    2005-01-01

    Resetting of previously accumulated optically stimulated luminescence (OSL) signals during transport of sediment is a fundamental requirement for reliable optical dating. The completeness of optical resetting of 46 modern-age quartz samples from a variety of depositional environments was examined. All equivalent dose (D e ) estimates were e from easy-to-bleach through to hard-to-bleach components. For all modern fluvial samples with non-zero D e values, SAR D e (t) analysis and component-resolved linearly modulated OSL (LM OSL) D e estimates showed this to be the case, implying incomplete resetting of previously accumulated charge. LM OSL measurements were also made to investigate the extent of bleaching of the slow components in the natural environment. In aeolian sediments examined, the natural LM OSL was effectively zero (i.e. all components were fully reset). The slow components of modern fluvial samples displayed measurable residual signals up to 15Gy

  19. Experimental and modelling study of pulsed optically stimulated luminescence in quartz, marble and beta irradiated salt

    International Nuclear Information System (INIS)

    Pagonis, V; Mian, S M; Barnold, C; Chithambo, M L; Christensen, E

    2009-01-01

    Optical stimulation luminescence (OSL) signals can be obtained using continuous-wave optical stimulation (CW-OSL), the linear modulation optical stimulation method (LM-OSL) and the time-resolved optical stimulation (TR-OSL) method. During TR-OSL measurements, the stimulation and emission of luminescence are experimentally separated in time by using short light pulses. This paper presents new TR-OSL data for annealed high purity synthetic quartz, for marble and for commercially available iodized salt. A new type of behaviour for TR-OSL signals for quartz and iodized salt is presented, in which the OSL signal exhibits a nonmonotonic behaviour during optical stimulation; this type of behaviour has not been reported previously in the literature for quartz. Furthermore, a luminescence component with very long luminescence lifetime is reported for some quartz aliquots, which may be due to the presence of a delayed-OSL (DOSL) mechanism in quartz. A new kinetic model for TR-OSL in quartz is presented, which is based on a main electron trap and on several luminescence centres. The model is used to quantitatively fit several sets of experimental data of pulsed optically stimulated luminescence from quartz.

  20. Development of an Equipment for Measuring OSL

    International Nuclear Information System (INIS)

    Chung, Ki Soo; Choe, Hong Soo

    2010-05-01

    A measurement system optically simulated luminescence (OSL) and thermoluminescence (TL) is developed. The system is composed by stimulation light part assembled by 3 ea of high brightness blue LEDs, temperature control system which can be controlled from room temperature to 300 .deg. C and filter package for separation of OSL and stimulation light with GG-420 and U-340 optical filters. The system was tested using Al 2 O 3 C OSL samples and a typical OSL curves were obtained. In addition, several OSL curves from LiAlO 2 C (a candidate of new OSLD material) were obtained and analyzed. A new algorithm for analysis of OSL curve and software (TOLAnal, Windows based) is developed and tested

  1. Measurement of optically and thermally stimulated electron emission from natural minerals

    DEFF Research Database (Denmark)

    Ankjærgaard, C.; Murray, A.S.; Denby, P.M.

    2006-01-01

    to a Riso TL/OSL reader, enabling optically stimulated electrons (OSE) and thermally stimulated electrons (TSE) to be measured simultaneously with optically stimulated luminescence (OSL) and thermoluminescence (TL). Repeated irradiation and measurement is possible without removing the sample from...... the counting chamber. Using this equipment both OSE and TSE from loose sand-sized grains of natural minerals has been recorded. It is shown that both the surface electron traps (giving rise to the OSE signals) and the bulk traps (giving rise to OSL) have the same dosimetric properties. A comparison of OSL...

  2. Mortar and surface dating with Optically Stimulated Luminescence (OSL): Innovative techniques for the age determination of buildings

    International Nuclear Information System (INIS)

    Panzeri, L.

    2013-01-01

    In this work the results of a dating study on bricks and mortars using both Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) are shown. The samples came from the outside walls of the Certosa di Pavia, located in northern Italy and independently dated (XVII-XVIII century). TL dating, applied to bricks using the fine grain technique, allowed to determine the time of manufacture of the bricks (XII century), that resulted therefore re-used. To circumvent this problem the application of two innovative dating techniques, OSL surface dating and mortar dating, was attempted. The first was applied to the light-shielded surfaces of bricks and allowed to successfully determine the edification of the wall (XVII century). Mortar dating gave instead severe age overestimation: the results obtained on coarse grain quartz with the SAR technique both on multi-grains aliquots and with single-grain analyses were highly dispersed indicating an incomplete bleaching of the quartz grains. The shine-down curves were in fact characterized by the absence of the so-called fast component, as confirmed by Linear Modulated OSL technique.

  3. Blue light emitting diodes for optical stimulation of quartz in retrospective dosimetry and dating

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Duller, G.A.T.; Murray, A.S.

    1999-01-01

    Recently developed blue light emitting diodes (LEDs) for the optical stimulation of quartz for use in routine optically stimulated luminescence (OSL) dating and retrospective dosimetry have been tested. For similar power densities, it was found that the higher energy light provided by the blue LE......, preliminary results from ramping the blue light power output with time are demonstrated. It is shown that this technique enables the separation of OSL components with differing stimulation rates.......Recently developed blue light emitting diodes (LEDs) for the optical stimulation of quartz for use in routine optically stimulated luminescence (OSL) dating and retrospective dosimetry have been tested. For similar power densities, it was found that the higher energy light provided by the blue LEDs...... (470 nm) gives order of magnitude greater rate of stimulation in quartz than that from conventional blue-green light filtered from a halogen lamp. A practical blue LED OSL configuration is described. From comparisons of OSL decay curves produced by green and blue light sources, and by examination...

  4. Real time dose rate measurements with fiber optic probes based on the RL and OSL of beryllium oxide

    International Nuclear Information System (INIS)

    Teichmann, T.; Sponner, J.; Jakobi, Ch.; Henniger, J.

    2016-01-01

    This work covers the examination of fiber optical probes based on the radioluminescence and real time optically stimulated luminescence of beryllium oxide. Experiments are carried out to determine the fundamental dosimetric and temporal properties of the system and evaluate its suitability for dose rate measurements in brachytherapy and other applications using non-pulsed radiation fields. For this purpose the responses of the radioluminescence and optically stimulated luminescence signal have been investigated in the dose rate range of 20 mGy/h to 3.6 Gy/h and for doses of 1 mGy up to 6 Gy. Furthermore, a new, efficient analysis procedure, the double phase reference summing, is introduced, leading to a real time optically stimulated luminescence signal. This method allows a complete compensation of the stem effect during the measurement. In contrast to previous works, the stimulation of the 1 mm cylindrical beryllium oxide detectors is performed with a symmetric function during irradiation. The investigated dose rates range from 0.3 to 3.6 Gy/h. The real time optically stimulated luminescence signal of beryllium oxide shows a dependency on both the dose rate and the applied dose. To overcome the problem of dose dependency, further experiments using higher stimulation intensities have to follow. - Highlights: • RL and OSL measurements with BeO extended to low dose (rate) range. • A new method to obtain the real time OSL: Dual Phase Reference Summing. • Real time OSL signal shows both dose and dose rate dependency. • Real time OSL enables a complete discrimination of the stem effect.

  5. Constraining Middle Pleistocene Glaciations in Birmingham, England; Using Optical Stimulated Luminescence (OSL) Dating.

    Science.gov (United States)

    Gibson, S. M.; Gibbard, P. L.; Bateman, M. D.; Boreham, S.

    2014-12-01

    Birmingham is built on a complex sequence of Middle Pleistocene sediments, representing at least three lowland glaciations (MIS12, MIS6, and MIS2). British Geological Survey mapping accounts 75% of the land mass as Quaternary deposits; predominantly glacial-sandy tills, glacial-fluvial sands, clays and organic silts and peats. Understanding the age of fluvial-glacial outwash, related to specific glaciations, is critical in establishing a Geochronology of Birmingham. Shotton (1953) found a series of Middle Pleistocene glacial sediments, termed the Wolstonian, intermediate in age between MIS11 and MIS5e Interglacial's. Uncertainty surrounding the relation to East Anglian sequences developed by Rose (1987) implies Birmingham sequences should be referred to MIS12. Despite this, younger Middle Pleistocene glacial sequences occur in Birmingham, yet uncertainty has deepened over our understanding of the complex, inaccessible sediments, especially as deposits have similar extent with MIS2 sequences. Five Optical Stimulated Luminescence (OSL) dates from three sites around Birmingham have been sampled. East of Birmingham, ice advanced from the Irish Sea and later the North East. In Wolston, a sample of outwash sand, associated with the Thurssington Till, is dated. In Meriden, two samples of outwash sands, associated with a distal Oadby Till, are dated. West of Birmingham, ice advanced from the Welsh Ice Sheet. In Seisdon, two samples of an Esker and outwash sand, associated with a Ridgeacre Till, are dated. Correlation of OSL dates provide an important constraint on understanding the history of Birmingham. Using GSI3D modeling to correlate geochronology and sedimentology, the significance of OSL dating can be understood within the complex sequences (and regional stratigraphy), complimented by Cosmogenic and Palynology dates taken in South West and North East. OSL dating on Birmingham's outwash sands, deposited by extensive repeated Middle Pleistocene glaciations, asserts the

  6. Development of optically stimulated luminescence reader systems in BARC

    International Nuclear Information System (INIS)

    Kulkarni, M.S.

    2008-01-01

    BARC has very vast experience in the development of thermoluminescence (TL) reader systems both for routine personnel monitoring and research application. However, optically stimulated luminescence (OSL) related instrumentation is a recent development in BARC. The increasing popularity of OSL technique in the radiation dosimetry applications in the recent past has driven investigation and developmental programme in the OSL measurement facilities at BARC. As the consequence of the efforts directed towards the indigenous development of OSL reader system, OSL readers with various readout modes like continuous wave (CW) OSL mode, linear intensity modulated OSL (LM-OSL), pulsed OSL (POSL) have been developed. In addition to these conventional modes of operation a novel non-linear OSL mode (NL-OSL) has also been developed for the OSL measurements. This paper reviews the details of the development of OSL reader system including experience with high intensity blue/green LED stimulation light source and detection system. Also discussed are recently developed versatile integrated TL/OSL reader systems for TL and OSL measurements. (author)

  7. The origin of the medium OSL component in West Australian quartz

    International Nuclear Information System (INIS)

    Wang, X.L.; Du, J.H.; Adamiec, G.; Wintle, A.G.

    2015-01-01

    Optically stimulated luminescence (OSL) of a coarse-grained sedimentary quartz from West Australia was investigated. Observations of OSL and TL (thermoluminescence) were made following a series of experiments using different heating and optical bleaching conditions, and with optical stimulation at several different temperatures. Analysis of the fast and medium OSL components suggests that the medium OSL component observed after heating at 260 °C is a by-product of the production of the fast component, and both of them have as their original source the 325 °C TL trap. During fast OSL production following irradiation and preheating, some of the electrons evicted into the conduction band are re-trapped in an intermediate trap corresponding to the 170 °C TL peak; from here they are instantaneously stimulated to give rise to the medium OSL signal when the blue light stimulation is switched on, and subsequently result in the residual recuperated TL after the blue light is switched off. The kinetic properties of the medium OSL component are determined by the properties of both the 170 °C and 325 °C TL traps in contrast to the conventional interpretation of the medium component being derived from an independent source trap. Therefore, the 170 °C TL trap also plays unexpected roles in quartz OSL production with elevated stimulation temperatures (e.g. 125 °C or 130 °C, currently used for OSL dating), while the 110 °C TL trap and its influences are being avoided. - Highlights: • Quartz medium OSL component is a by-product of fast OSL component production. • Medium component is mediated by the 170 C TL peak. • Phototransfer is responsible for the medium OSL

  8. Scintillation and optical stimulated luminescence of Ce-doped CaF2

    International Nuclear Information System (INIS)

    Yanagida, Takayuki; Fujimoto, Yutaka; Watanabe, Kenichi; Fukuda, Kentaro; Kawaguchi, Noriaki; Miyamoto, Yuka; Nanto, Hidehito

    2014-01-01

    Scintillation and optical stimulated luminescence of Ce 0.1–20% doped CaF 2 crystals prepared by Tokuyama Corp. were investigated. In X-ray induced scintillation spectra, luminescence due to Ce 3+ 5d–4f transition appeared around 320 nm with typically 40 ns decay time. By 241 Am 5.5 MeV α-ray irradiation, 0.1% doped one showed the highest scintillation light yield and the light yield monotonically decreased with Ce concentrations. Optically stimulated luminescence after X-ray irradiation was observed around 320 nm under 550 or 830 nm stimulation in all samples. As a result, intensities of optically stimulated luminescence were proportional to Ce concentrations. Consequently, scintillation and optically stimulated luminescence resulted to have a complementary relation in Ce-doped CaF 2 system. - Highlights: • Optical, scintillation, and OSL properties of Ce 0.1–20% doped CaF 2 were studied. • Scintillation light yield exhibited inverse proportionality to Ce concentrations. • OSL intensities showed proportionality to Ce concentrations. • Complementary relation of scintillation and OSL was experimentally confirmed

  9. Developing a SAR TT-OSL protocol for volcanically-heated aeolian quartz from Datong (China)

    DEFF Research Database (Denmark)

    Liu, Jinfeng; Murray, Andrew S.; Jain, Mayank

    2012-01-01

    The thermally-transferred optically stimulated luminescence (TT-OSL) responses of chemically-purified fine-grained quartz from a lava-baked aeolian sediment from Datong (China) are presented. Our main focus is to examine the suitability of the test dose TT-OSL and OSL response to monitor sensitiv......The thermally-transferred optically stimulated luminescence (TT-OSL) responses of chemically-purified fine-grained quartz from a lava-baked aeolian sediment from Datong (China) are presented. Our main focus is to examine the suitability of the test dose TT-OSL and OSL response to monitor...

  10. Influence of thermal treatment on OSL regeneration in potassium chloride

    International Nuclear Information System (INIS)

    Majgier, Renata; Biernacka, Magdalena; Mandowski, Arkadiusz

    2016-01-01

    Optically stimulated luminescence (OSL) of pure analytical potassium chloride (KCl) prepared in two different forms (crystals and pellets) was studied. The occurrence of regeneration effect (self-renewal of the OSL signal) in the material was examined. The experiments using the variable delay OSL (VD-OSL) method were carried out. Performed measurements allowed to determine time scale of the phenomenon, as well as quantitative changes of regeneration depending on thermal treatment before and after irradiation. Significant increase of the OSL regeneration was noticeable for pellets after the application of the annealing before irradiation, while for crystals a substantial decrease of regeneration was observed. Preheating applied after irradiation caused that self-renewal of OSL signal was drastically reduced or completely suppressed depending on the form of KCl samples. - Highlights: • Optically stimulated luminescence (OSL) of potassium chloride (KCl) was studied. • The measurements were performed using the variable delay OSL method (VD-OSL). • It was found that regeneration of OSL intensity in KCl could be as high as 2000%. • Annealing caused reduction of OSL renewal for crystals and its increase for pellets. • Preheating after irradiation removed or significantly reduced the OSL regeneration.

  11. Container Verification Using Optically Stimulated Luminescence

    International Nuclear Information System (INIS)

    Tanner, Jennifer E.; Miller, Steven D.; Conrady, Matthew M.; Simmons, Kevin L.; Tinker, Michael R.

    2008-01-01

    Containment verification is a high priority for safeguards containment and surveillance. Nuclear material containers, safeguards equipment cabinets, camera housings, and detector cable conduit are all vulnerable to tampering. Even with a high security seal on a lid or door, custom-built hinges and interfaces, and special colors and types of finishes, the surfaces of enclosures can be tampered with and any penetrations repaired and covered over. With today's technology, these repairs would not be detected during a simple visual inspection. Several suggested solutions have been to develop complicated networks of wires, fiber-optic cables, lasers or other sensors that line the inside of a container and alarm when the network is disturbed. This results in an active system with real time evidence of tampering but is probably not practical for most safeguards applications. A more practical solution would be to use a passive approach where an additional security feature was added to surfaces which would consist of a special coating or paint applied to the container or enclosure. One type of coating would incorporate optically stimulated luminescent (OSL) material. OSL materials are phosphors that luminesce in proportion to the ionizing radiation dose when stimulated with the appropriate optical wavelengths. The OSL fluoresces at a very specific wavelength when illuminated at another, very specific wavelength. The presence of the pre-irradiated OSL material in the coating is confirmed using a device that interrogates the surface of the enclosure using the appropriate optical wavelength and then reads the resulting luminescence. The presence of the OSL indicates that the integrity of the surface is intact. The coating itself could be transparent which would allow the appearance of the container to remain unchanged or the OSL material could be incorporated into certain paints or epoxies used on various types of containers. The coating could be applied during manufacturing

  12. Optically stimulated luminescence dosimetry using natural and synthetic materials

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; McKeever, S.W.S.

    1996-01-01

    The application of optically stimulated luminescence (OSL) for use in radiation dosimetry is reviewed. A broad description is given of OSL techniques developed at Riso National Laboratory and at Oklahoma State University, and recent collaborative investigations on the properties of a variety...

  13. Understanding optically stimulated charge movement in quartz and feldspar using time-resolved measurements

    International Nuclear Information System (INIS)

    Ankjaergaard, C.

    2010-02-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) from quartz and feldspar are widely used in accident dosimetry and luminescence dating. In order to improve already existing methods or to develop new methods towards extending the current limits of the technique, it is important to understand the charge movement within these materials. Earlier studies have primarily focussed on examination of the trap behaviour; however, this only tells half of the story as OSL is a combination of charge stimulation and recombination. By using time-resolved OSL (TR-OSL), one can directly examine the recombination route(s), and thus obtain insight into the other half of the process involved in luminescence emission. This thesis studies the TR-OSL and optically stimulated phosphorescence signals from quartz and feldspars spanning several orders of magnitude in time (few ns to the seconds time scale) in order to identify various charge transport mechanisms in the different time regimes. The techniques employed are time-resolved OSL, continuous-wave OSL, TL, optically stimulated exo-electron (OSE) emission and time-resolved OSE. These different techniques are used in combination with variable thermal or optical stimulation energy. The thesis first delves into three main methodological developments, namely (i) research and development of the equipment for TR-OSL measurements, (ii) finding the best method for multiple-exponential analysis of a TR-OSL curve, and (iii) optimisation of the pulsing configuration for the best separation of quartz OSL from a mixed quarts-feldspar sample. It then proceeds to study the different charge transport mechanisms subsequent to an optical stimulation pulse in quartz and feldspars. The results obtained for quartz conclude that the main lifetime component in quartz represents an excited state lifetime of the recombination centre, and the more slowly decaying components on the millisecond to seconds time scale arise from charge recycling

  14. Understanding optically stimulated charge movement in quartz and feldspar using time-resolved measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ankjaergaard, C.

    2010-02-15

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) from quartz and feldspar are widely used in accident dosimetry and luminescence dating. In order to improve already existing methods or to develop new methods towards extending the current limits of the technique, it is important to understand the charge movement within these materials. Earlier studies have primarily focussed on examination of the trap behaviour; however, this only tells half of the story as OSL is a combination of charge stimulation and recombination. By using time-resolved OSL (TR-OSL), one can directly examine the recombination route(s), and thus obtain insight into the other half of the process involved in luminescence emission. This thesis studies the TR-OSL and optically stimulated phosphorescence signals from quartz and feldspars spanning several orders of magnitude in time (few ns to the seconds time scale) in order to identify various charge transport mechanisms in the different time regimes. The techniques employed are time-resolved OSL, continuous-wave OSL, TL, optically stimulated exo-electron (OSE) emission and time-resolved OSE. These different techniques are used in combination with variable thermal or optical stimulation energy. The thesis first delves into three main methodological developments, namely (i) research and development of the equipment for TR-OSL measurements, (ii) finding the best method for multiple-exponential analysis of a TR-OSL curve, and (iii) optimisation of the pulsing configuration for the best separation of quartz OSL from a mixed quarts-feldspar sample. It then proceeds to study the different charge transport mechanisms subsequent to an optical stimulation pulse in quartz and feldspars. The results obtained for quartz conclude that the main lifetime component in quartz represents an excited state lifetime of the recombination centre, and the more slowly decaying components on the millisecond to seconds time scale arise from charge recycling

  15. Optically stimulated luminescence from quartz measured using the linear modulation technique

    International Nuclear Information System (INIS)

    Bulur, E.; Boetter-Jensen, L.; Murray, A.S.

    2000-01-01

    The optically stimulated luminescence (OSL) from heated natural quartz has been investigated using the linear modulation technique (LMT), in which the excitation light intensity is increased linearly during stimulation. In contrast to conventional stimulation, which usually produces a monotonically decreasing signal, linearly increasing the stimulation power gives peaks in the signal as a function of time. In cases where the OSL signal contains more than one component, the linear increase in power of the stimulation light may result in a curve containing overlapping peaks, where the most easily stimulated component occurs at a shorter time. This allows the separation of the overlapping OSL components, which are assumed to originate from different traps. The LM-OSL curve from quartz shows an initial peak followed by a broad one. Deconvolution using curve fitting has shown that the composite OSL curve from quartz can be approximated well by using a linear combination of first-order peaks. In addition to the three known components, i.e. fast, medium and slow components from continuous-wave-OSL studies, an additional slow component is also identified for the first time. The dose responses and thermal stabilities of the various components are also studied

  16. More on the TR-OSL signal from BeO ceramics

    International Nuclear Information System (INIS)

    Bulur, Enver

    2014-01-01

    Time Resolved Optically Stimulated Luminescence (TR-OSL) from BeO ceramics was investigated using blue (445 nm) and near-IR light (852 nm) for stimulation. Stimulation spectrum of the TR-OSL signal – as measured in the interval 700 to 420 nm- was observed to increase monotonically with the decreasing stimulation wavelength. In addition to the “fast” and “slow” components observed with blue light stimulation, IR stimulated TR-OSL spectra of irradiated BeO ceramics were observed to have two components with average lifetimes around ∼2.5 μs and ∼17 μs. Emission spectra of the both IR stimulated TR-OSL components were observed to have a broad emission band peaking around 330 nm. Thermal stability of the IR stimulated TR-OSL signal was studied by making preheating experiments in the range from 100 °C to 190 °C. It was observed that the IR stimulated OSL signal is stable up to ∼150 °C and decay afterwards. Radiation dose response of the IR stimulated luminescence signal was obtained in the range from 5 to 500 Gy. Both blue and IR stimulated TR-OSL signals grew up to 100 Gy and exhibited saturation for higher doses. Additionally, measurement temperature dependence of the components was also investigated and for the ∼2 μs component thermal assistance with activation energy around 0.16 eV was observed. It seems that the fast component of the blue stimulated TR-OSL component can be correlated to the ∼2 μs IR stimulated TR-OSL component. - Highlights: • IR Stimulated Time-Resolved OSL from BeO was studied. • Two components with lifetimes ∼2 and ∼17us were observed. • IR stimulated TR-OSL signal is found to be stable up to 150 °C. • Thermal quenching energy of the 2us component was found as 0.16 eV

  17. Analysis of optical bleaching of OSL signal in sediment quartz

    International Nuclear Information System (INIS)

    Przegiętka, K.R.; Chruścińska, A.

    2013-01-01

    The aim of this work was to study the effect of the quality of optical bleaching on the results of OSL (Optically Stimulated Luminescence) dating method. The large aliquots of coarse quartz grains extracted from fluvial deposit were used in the study. The poor, medium and good bleaching were simulated in laboratory with help of Blue LED light source in series of experiments. Then the samples were irradiated with a common laboratory dose. The equivalent doses (DE) were measured by the help of standard Single Aliquot Regeneration (SAR) technique, but obtained DE distributions are analyzed in a new way. The method for recognizing and compensating for partial bleaching is proposed. The conclusions for dating sediment quartz samples are presented and discussed. -- Highlights: ► Bleaching experiments on sediment quartz are performed. ► Blue LED light source incorporated in luminescence reader is used. ► New analysis of data measured by standard SAR OSL technique is proposed. ► The results are promising for recognizing and compensating for partial bleaching

  18. Analytical expressions for time-resolved optically stimulated luminescence experiments in quartz

    International Nuclear Information System (INIS)

    Pagonis, V.; Lawless, J.; Chen, R.; Chithambo, M.L.

    2011-01-01

    Optically stimulated luminescence (OSL) signals can be obtained using a time-resolved optical stimulation (TR-OSL) method, also known as pulsed OSL. During TR-OSL measurements, the stimulation and emission of luminescence are experimentally separated in time using short light pulses. This paper presents analytical expressions for the TR-OSL intensity observed during and after such a pulse in quartz experiments. The analytical expressions are derived using a recently published kinetic model which describes thermal quenching phenomena in quartz samples. In addition, analytical expressions are derived for the concentration of electrons in the conduction band during and after the TR-OSL pulse, and for the maximum signals attained during optical stimulation of the samples. The relevance of the model for dosimetric applications is examined, by studying the dependence of the maximum TR-OSL signals on the degree of initial trap filling, and also on the probability of electron retrapping into the dosimetric trap. Analytical expressions are derived for two characteristic times of the TR-OSL mechanism; these times are the relaxation time for electrons in the conduction band, and the corresponding relaxation time for the radiative transition within the luminescence center. The former relaxation time is found to depend on several experimental parameters, while the latter relaxation time depends only on internal parameters characteristic of the recombination center. These differences between the two relaxation times can be explained by the presence of localized and delocalized transitions in the quartz sample. The analytical expressions in this paper are shown to be equivalent to previous analytical expressions derived using a different mathematical approach. A description of thermal quenching processes in quartz based on AlO 4 - /AlO 4 defects is presented, which illustrates the connection between the different descriptions of the luminescence process found in the literature

  19. Dosimetry based on thermally and optically stimulated luminescence

    International Nuclear Information System (INIS)

    Agersnap Larsen, Niels

    1999-01-01

    Thermally Stimulated Luminescence (TL) and Optically Stimulated Luminescence (OSL) properties of quartz and α-Al 2 O 3 have been investigated. Anneling-induced OSL and TL sensitivity changes in quartz has been investigated by experiments and modelling. This study does not support a pre-dose effect to account for the observed annealing-induced sensitivity change. The experimental data indicates a more simple mechanism that involves alteration of the concentration of the defect centers. Results from modelling of removal or creation of defect centers comparing well with experimentally obtained data. Thermal quenching of luminescence for the main emission center, the F-center, in α-Al 2 O 3 :C has been investigated by analysing TL curves obtained at different heating rates. The thermal quenching dependence of luminescence is found to follow the classical Mott-Seitz expression. Basic investigations of OSL properties of αAl 2 O 3 :C, including: the thermal depth of the OSL traps, the temperature dependence of OSL, and the OSL stimulation spectra. Simultaneous measurements of TL and thermally stimulated conductivity (TSC) are presented for γ-irradiated αAl 2 O 3 :C. Activation energy analysis of the data reveals a superposition of several first-order TL and TSC peaks caused by release of charge carriers from a distribution of trapping states. Furthermore a description of an experimental method developed to determine the sign of the thermally released charge carriers has been presented. (au)

  20. Using optically stimulated electrons from quartz for the estimation of natural doses

    DEFF Research Database (Denmark)

    Ankjærgaard, Christina; Murray, A.S.; Denby, Phil M.

    2009-01-01

    A flow-through Geiger-Müller pancake electron detector attachment has been fitted to a standard Risø TL/OSL reader enabling optically stimulated electrons (OSE) to be measured simultaneously with optically stimulated luminescence (OSL). Using this detector, OSE and OSL measurements from natural......, a dose recovery test shows that OSE can successfully recover a laboratory dose of 300 Gy given before any laboratory thermal treatment, for preheating temperatures between 160 and 260 °C. Furthermore, for the first time natural OSE decay curves are detected and these signals are used to estimate a burial...... dose using the single-aliquot regenerative-dose (SAR) procedure. Finally, a comparative study of the equivalent doses estimated using both OSE and OSL from 10 quartz samples are presented, and it is shown that OSE has a significant potential in retrospective dosimetry....

  1. Optically stimulated luminescence properties of Tm3+ doped KMgF3 fluoro perovskite

    International Nuclear Information System (INIS)

    Camargo, L.; Marcazzo, J.; Perez C, L.; Cruz Zaragoza, E.; Martinez O, S. A.

    2017-10-01

    In this work the optically stimulated luminescence (OSL) properties of undoped and Tm 3+ doped KMgF 3 fluoro perovskite have been investigated for the first time. OSL efficiency for stimulation with different wavelengths has been analyzed for each compound. The maximum OSL emission was found with blue light stimulation. The radioluminescence (Rl) spectra have shown two emission peaks at 455 and 360 nm, which can be ascribed to the 1 D 2 - 3 F 4 and 1 D 2 - 3 H 6 transitions of the Tm 3+ cations. It has been found that doping with Thulium 0.5 mol % renders the most intense OSL emission. Furthermore, several dosimetric properties such as OSL response as a function of dose, reproducibility of the OSL signal after several cycles of irradiation readout and the minimum detectable dose have been investigated. Finally, the OSL response of KMgF 3 : Tm 3+ has been compared to that of commercial Al 2 O 3 :C and the possible application of this fluoro perovskite to OSL dosimetry has been evaluated. (Author)

  2. Dosimetry based on thermally and optically stimulated luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Agersnap Larsen, Niels

    1999-01-01

    Thermally Stimulated Luminescence (TL) and Optically Stimulated Luminescence (OSL) properties of quartz and {alpha}-Al{sub 2}O{sub 3} have been investigated. Anneling-induced OSL and TL sensitivity changes in quartz has been investigated by experiments and modelling. This study does not support a pre-dose effect to account for the observed annealing-induced sensitivity change. The experimental data indicates a more simple mechanism that involves alteration of the concentration of the defect centers. Results from modelling of removal or creation of defect centers comparing well with experimentally obtained data. Thermal quenching of luminescence for the main emission center, the F-center, in {alpha}-Al{sub 2}O{sub 3}:C has been investigated by analysing TL curves obtained at different heating rates. The thermal quenching dependence of luminescence is found to follow the classical Mott-Seitz expression. Basic investigations of OSL properties of {alpha}Al{sub 2}O{sub 3}:C, including: the thermal depth of the OSL traps, the temperature dependence of OSL, and the OSL stimulation spectra. Simultaneous measurements of TL and thermally stimulated conductivity (TSC) are presented for {gamma}-irradiated {alpha}Al{sub 2}O{sub 3}:C. Activation energy analysis of the data reveals a superposition of several first-order TL and TSC peaks caused by release of charge carriers from a distribution of trapping states. Furthermore a description of an experimental method developed to determine the sign of the thermally released charge carriers has been presented. (au) 8 tabs., 59 ills., 90 refs.

  3. Further investigations into pulsed optically stimulated luminescence from feldspars using blue and green light

    International Nuclear Information System (INIS)

    Ankjaergaard, C.; Jain, M.; Kalchgruber, R.; Lapp, T.; Klein, D.; McKeever, S.W.S.; Murray, A.S.; Morthekai, P.

    2009-01-01

    The purpose of this paper is to investigate characteristics of luminescence signals resulting from pulsed optical stimulation of feldspars and thereby to understand the underlying processes giving rise to the signal. Fourteen different feldspar specimens were investigated using time-resolved optically stimulated luminescence (TR-OSL), and these signals can be mathematically described as a sum of 4 exponential components (a, b, c, d). The slowest component, d, increases with the duration of the light pulse as expected from the exponential model. The stimulation temperature dependence experiment suggests that the TR-OSL signal decay is governed by the recombination process and not by the excited state lifetime. Furthermore data from the TR-OSL signal dependence on stimulation time and preheat temperature suggest that the recombination process may not be a sum of exponentials, although the model cannot be rejected definitively.

  4. Optically stimulated luminescence from quartz measured using the linear modulation technique

    DEFF Research Database (Denmark)

    Bulur, E.; Bøtter-Jensen, L.; Murray, A.S.

    2000-01-01

    The optically stimulated luminescence (OSL) from heated natural quartz has been investigated using the linear modulation technique (LMT), in which the excitation light intensity is increased linearly during stimulation. In contrast to conventional stimulation, which usually produces a monotonical...

  5. OSL, TL and IRSL emission spectra of sedimentary quartz and feldspar samples

    International Nuclear Information System (INIS)

    Lomax, Johanna; Mittelstraß, Dirk; Kreutzer, Sebastian; Fuchs, Markus

    2015-01-01

    This contribution presents a variety of different luminescence emission spectra from sedimentary feldspar and quartz samples under various stimulation modes. These are green stimulated quartz (OSL-) spectra, quartz TL spectra, feldspar IRSL and post-IR IRSL spectra. A focus was set at recording OSL and IRSL spectra at elevated stimulation temperatures such as routinely applied in luminescence dating. This was to test whether optical stimulation at elevated temperatures results in a shift of emission peaks. For OSL emissions of quartz, this has so far not been tested. In case of feldspar emissions, post-IR IRSL conditions, hence IRSL emissions at a low temperature, directly followed by high temperature post-IRSL emissions, are explicitly investigated. All spectra were recorded using a new system incorporated into a Lexsyg luminescence reader. Thus, this study, besides presenting new spectral data, also serves as a feasibility study for this new device. It is shown that (a) the new device is capable of automatically measuring different sorts of spectra, also at elevated temperatures, (b) known thermally and optically stimulated peak emissions of quartz and feldspar are confirmed, (c) obtained IRSL and OSL spectra indicate that there is no significant relation between peak emission and stimulation temperature. - Highlights: • We have measured OSL, IRSL and TL emission spectra of sedimentary quartz and feldspar samples. • Spectral analyses were performed at elevated stimulation temperatures. • Emission spectra show very little variation with stimulation temperatures.

  6. Understanding optically stimulated charge movement in quartz and feldspar using time-resolved measurements

    DEFF Research Database (Denmark)

    Ankjærgaard, Christina

    . Although, results are only presented for some quartz and feldspar samples, they were found to be very similar within the each group during the course of this work.Thermoluminescence (TL) and optically stimulated luminescence (OSL) from quartz and feldspar are widely used in accident dosimetry...... stimulation energy. The thesis first delves into three main methodological developments, namely (i) research and development of the equipment for TR-OSL measurements, (ii) finding the best method for multiple-exponential analysis of a TR-OSL curve, and (iii) optimisation of the pulsing configuration...... of the equipment for TR-OSL measurements, (ii) finding the best method for multiple-exponential analysis of a TR-OSL curve, and (iii) optimisation of the pulsing configuration for the best separation of quartz OSL from a mixed quarts-feldspar sample. It then proceeds to study the different charge transport...

  7. Alpha efficiency under TL and OSL - A subtraction technique using OSL and TL to detect artificial irradiation

    International Nuclear Information System (INIS)

    Zink, A.J.C.; Dabis, S.; Porto, E.; Castaing, J.

    2010-01-01

    With the development of thermoluminescence (TL) and optically stimulated luminescence (OSL) to determine the authenticity of old ceramics, forgers use artificial irradiation by gamma ray to age modern productions. Besides fraudulent action, objects can be exposed to various sources of X-rays (e.g. radiography, security control at airports). For all these reasons, the determination of artificial irradiation is an important topic for dating art objects. The main technique to identify artificial irradiations is the subtraction technique. It is based on the fact that alpha efficiency varies according to the luminescence technique (fine grain, coarse grains, predose, OSL). Having observed a rather significant difference of alpha efficiency for TL and OSL, we propose a new subtraction technique using OSL and TL of fine grains.

  8. Optically stimulated exoelectron emission processes in quartz: comparison of experiment and theory

    DEFF Research Database (Denmark)

    Pagonis, V.; Ankjærgaard, Christina; Murray, A.S.

    2009-01-01

    Recent experiments have demonstrated that it is possible to measure optically stimulated exoelectron emission (OSE) signals simultaneously with optically stimulated luminescence (OSL) from quartz samples. These experiments provide valuable information on the charge movement in quartz grains. Two...... data yield a value of χ1.2 eV for the work function of quartz. The experimental temperature dependence of the OSE signals is interpreted on the basis of a photo-thermostimulated (PTSEE) process involving the main OSL trap at 320 °C; this process takes place with a thermal assistance energy estimated...... at W(0.29±0.02) eV. Good quantitative agreement is obtained between theory and experiment by assuming a thermal broadening of the thermal depletion factor for the OSL traps, described by a Gaussian distribution of energies....

  9. Constraining the timing of palaeosol development in Iranian arid environments using OSL dating

    DEFF Research Database (Denmark)

    Rashidi, Zakieh; Sohbati, Reza; Karimi, Alireza

    2018-01-01

    are compared to investigate the degree of bleaching of quartz OSL in individual samples at the time of deposition. A comparison between the quartz OSL and K-feldspar IR50 ages shows that 12 out of 15 samples were probably well-bleached prior to deposition. The 17 OSL ages constrain at least four broad phases......The ages of palaeosols in arid environments in Iran are constrained using the optically stimulated luminescence (OSL) signal from quartz. The luminescence properties of quartz OSL and K-feldspar infrared stimulated luminescence (IRSL) at 50 °C (IR50) and post-IR IRSL at 290 °C (pIRIR290) signals...

  10. Correlation between TL and OSL properties of CaF2:N

    International Nuclear Information System (INIS)

    Polymeris, George S.; Kitis, George; Tsirliganis, Nestor C.

    2006-01-01

    Natural CaF 2 is very well known thermoluminescent (TL) material, since it has been extensively used as a dosimeter. Its basic advantage is the exhibited high TL sensitivity. In the present work, the optically stimulated luminescence (OSL) sensitivity of this material was studied by exposing it to environmental radiation for time intervals of few hours up to a few days, and was found to be very high. By analyzing the TL glow curves and the OSL decay curves into their individual glow-peaks and components respectively, a relation between specific glow-peaks and OSL components was established. An intense thermal transfer effect occurring during optical stimulation at high temperature was observed and an explanation is offered according to existing models

  11. The TL and OSL study of hydroxyapatites for dosimetric applications

    International Nuclear Information System (INIS)

    Alencar, Marcus A. Vallim de

    2009-01-01

    The hydroxyapatite, the principal mineral component of the bone and tooth enamel, is one of the dosimetric materials that has distinguished itself in the high dose and accidents dosimetry, as well as in the dating, for the Electron Paramagnetic Resonance (EPR) technique. For this reason, the hydroxyapatite could also be used as Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) dosimeter in the dosimetry of high doses and accidents, and also in the archaeological and geological dating. This work presents a brief study of the TL and OSL behaviour of the B type synthetic carbonated hydroxyapatite, observing the possibility to use this material in TL and OSL dosimetry. The samples were irradiated to a dose of 100 Gy and 1000 Gy, and the TL and OSL measurements were obtained by the RISOE TL/OSL reader, model TL/OSL-DA-15B. The first results demonstrate the presence of three peaks in the TL glow curve in the temperatures of 100 deg C, 150 deg C and 280 deg C. The synthetic carbonated hydroxyapatite also presents an OSL signal when the sample is stimulated with blue light and a small OSL signal for stimulation with infrared light (IR). These results indicate the possibility of this synthetic carbonated hydroxyapatite to be used as dose indicator material using the TL and OSL techniques. (author)

  12. A new luminescence detection and stimulation head for the Risø TL/OSL reader

    International Nuclear Information System (INIS)

    Lapp, T.; Kook, M.; Murray, A.S.; Thomsen, K.J.; Buylaert, J.-P.; Jain, M.

    2015-01-01

    A new automated Detection And Stimulation Head (DASH) has been developed for the Risø TL/OSL luminescence reader to provide easy access to new technologies, new signals and new measurement methods. The automated DASH includes a filter changer and a detector changer that makes it possible to change stimulation filters (4 × 4 filter combinations possible) and detectors (3 detectors possible) as part of a measurements sequence. The new automated DASH with dedicated driver electronics does not affect the use of other attachments, and can be retrospectively fitted to existing Risø TL/OSL readers. - Highlights: • A new detection and stimulation head for the Risø TL/OSL reader is described. • An example of the use of the filter changer is presented. • The power and spatial uniformity of blue, green and IR stimulation are characterised. • The potential of an EMCCD camera detector is described.

  13. Charge recombination processes in minerals studied using optically stimulated luminescence and time-resolved exo-electrons

    DEFF Research Database (Denmark)

    Tsukamoto, Sumiko; Murray, Andrew; Ankjærgaard, Christina

    2010-01-01

    electron concentration in the conduction band. In this study, TR-OSE and time-resolved optically stimulated luminescence (TR-OSL) were measured for the first time using quartz, K-feldspar and NaCl by stimulating the samples using pulsed blue LEDs at different temperatures between 50 and 250 °C after beta...... irradiation and preheating to 280 °C. The majority of TR-OSE signals from all the samples decayed much faster than TR-OSL signals irrespective of the stimulation temperatures. This suggests that the lifetime of OSL in these dosimeters arises mainly from the relaxation of an excited state of the recombination...

  14. Blue Light Emitting Diodes for Optical Stimulation of Quartz in Retrospective Dosimetry and Dating (invited paper)

    International Nuclear Information System (INIS)

    Botter-Jensen, L.; Duller, G.A.T.; Murray, A.S.; Banerjee, D.

    1999-01-01

    Recently developed blue light emitting diodes (LEDs) for the optical stimulation of quartz for use in routine optically stimulated luminescence (OSL) dating and retrospective dosimetry have been tested. For similar power densities, it was found that the higher energy light provided by the blue LEDs (470 nm) gives order of magnitude greater rate of stimulation in quartz than that from conventional blue-green light filtered from a halogen lamp. A practical blue LED OSL configuration is described. From comparisons of OSL decay curves produced by green and blue light sources, and by examination of the dependence of the blue LED OSL on preheat temperature, it is deduced that there is no evidence that the blue LEDs stimulate deep traps in a different manner from broadband filtered light. It is concluded that blue LEDs offer a practical alternative to existing stimulation sources. They have the significant advantages that the life-time is indefinite, and the output can be controlled electronically; this allows the power to be readily controlled by software. Unlike a filtered light source, there are no electromechanical parts, and the switch on/off times are about 10 times faster than a shutter. Finally, preliminary results from ramping the blue light power output with time are demonstrated. It is shown that this technique enables the separation of OSL components with differing stimulation rates. (author)

  15. Optically stimulated luminescence properties of Tm{sup 3+} doped KMgF{sub 3} fluoro perovskite

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, L.; Marcazzo, J. [UNCPBA, Facultad de Ciencias Exactas, Instituto de Fisica Arroyo Seco, Gral. Pinto 399, B7000GHG Tandil, Buenos Aires (Argentina); Perez C, L.; Cruz Zaragoza, E. [UNAM, Instituto de Ciencias Nucleares, Apdo. Postal 70543, 04510 Ciudad de Mexico (Mexico); Martinez O, S. A., E-mail: jmarcass@exa.unicen.edu.ar [Universidad Pedagogica y Tecnologica de Colombia, Grupo de Fisica Nuclear Aplicada y Simulacion, Av. Central del Norte 39-115, 150003 Tunja, Bocaya (Colombia)

    2017-10-15

    In this work the optically stimulated luminescence (OSL) properties of undoped and Tm{sup 3+} doped KMgF{sub 3} fluoro perovskite have been investigated for the first time. OSL efficiency for stimulation with different wavelengths has been analyzed for each compound. The maximum OSL emission was found with blue light stimulation. The radioluminescence (Rl) spectra have shown two emission peaks at 455 and 360 nm, which can be ascribed to the {sup 1}D{sub 2}-{sup 3}F{sub 4} and {sup 1}D{sub 2}-{sup 3}H{sub 6} transitions of the Tm{sup 3+} cations. It has been found that doping with Thulium 0.5 mol % renders the most intense OSL emission. Furthermore, several dosimetric properties such as OSL response as a function of dose, reproducibility of the OSL signal after several cycles of irradiation readout and the minimum detectable dose have been investigated. Finally, the OSL response of KMgF{sub 3}: Tm{sup 3+} has been compared to that of commercial Al{sub 2}O{sub 3}:C and the possible application of this fluoro perovskite to OSL dosimetry has been evaluated. (Author)

  16. A simple transformation for converting CW-OSL curves to LM-OSL curves

    DEFF Research Database (Denmark)

    Bulur, E.

    2000-01-01

    A simple mathematical transformation is introduced to convert from OSL decay curves obtained in the conventional way to those obtained using a linear modulation technique based on a linear increase of the stimulation light intensity during OSL measurement. The validity of the transformation...... was tested by the IR-stimulated luminescence curves from feldspars, recorded using both the conventional and the linear modulation techniques. The transformation was further applied to green-light-stimulated OSL from K and Na feldspars. (C) 2000 Elsevier Science Ltd. All rights reserved....

  17. OSL response bleaching of BeO samples, using fluorescent light and blue LEDs

    International Nuclear Information System (INIS)

    Groppo, Daniela Piai; Caldas, Linda V.E.

    2015-01-01

    The optically stimulated luminescence (OSL) is widely used as a dosimetric technique for many applications. In this work, the OSL response bleaching of BeO samples was studied. The samples were irradiated using a beta radiation source ( 90 Sr+ 90 Y); the bleaching treatments (fluorescent light and blue LEDs) were performed, and the results were compared. Various optical treatment time intervals were tested until reaching the complete bleaching of the OSL response. The best combination of the time interval and bleaching type was analyzed. (author)

  18. OSL response bleaching of BeO samples, using fluorescent light and blue LEDs

    International Nuclear Information System (INIS)

    Groppo, D P; Caldas, L V E

    2016-01-01

    The optically stimulated luminescence (OSL) is widely used as a dosimetric technique for many applications. In this work, the OSL response bleaching of BeO samples was studied. The samples were irradiated using a beta radiation source ("9"0Sr+"9"0Y); the bleaching treatments (fluorescent light and blue LEDs) were performed, and the results were compared. Various optical treatment time intervals were tested until reaching the complete bleaching of the OSL response. The best combination of the time interval and bleaching type was analyzed. (paper)

  19. Charge recombination processes in minerals studied using optically stimulated luminescence and time-resolved exo-electrons

    International Nuclear Information System (INIS)

    Tsukamoto, Sumiko; Murray, Andrew; Ankjaergaard, Christina; Jain, Mayank; Lapp, Torben

    2010-01-01

    A time-resolved optically stimulated exo-electron (TR-OSE) measurement system has been developed using a Photon Timer attached to a gas-flow semi-proportional pancake electron detector within a Risoe TL/OSL reader. The decay rate of the exo-electron emission after the stimulation pulse depends on the probability of (1) escape of electrons into the detector gas from the conduction band by overcoming the work function of the material and (2) thermalization of electrons in the conduction band, and subsequent re-trapping/recombination. Thus, we expect the exo-electron signal to reflect the instantaneous electron concentration in the conduction band. In this study, TR-OSE and time-resolved optically stimulated luminescence (TR-OSL) were measured for the first time using quartz, K-feldspar and NaCl by stimulating the samples using pulsed blue LEDs at different temperatures between 50 and 250 0 C after beta irradiation and preheating to 280 0 C. The majority of TR-OSE signals from all the samples decayed much faster than TR-OSL signals irrespective of the stimulation temperatures. This suggests that the lifetime of OSL in these dosimeters arises mainly from the relaxation of an excited state of the recombination centre, rather than from residence time of an electron in the conduction band.

  20. Modelling the thermal bleaching of OSL signal in the case of a competition between recombination centres

    International Nuclear Information System (INIS)

    Chruscinska, A.

    2009-01-01

    The thermal bleaching of the optically stimulated luminescence (OSL) has been investigated by computer simulations for a model including three traps and two luminescence centres. The deepest trap is active only during the OSL process. Two other traps are active only during the thermal bleaching. The thermal bleaching effects on the OSL intensity as well as on the OSL curve shape are presented for the wide range of trap and luminescence centre parameters and for the different settings of optical detection window. The conventional OSL curve analysis consisting in decomposition of the OSL curve into first order components is applied to the simulation results and the optical cross section spectra obtained as a result of this analysis are compared with the model assumptions. The simulations show that OSL signal can decrease to undetectable level even when the traps related to this signal are not emptied during thermal bleaching. The residual level of the OSL signal after bleaching process, however, depends strongly on centre parameters and concentrations. The modifications of optical detection spectral window lead to significant changes of bleaching effects. The thermal bleaching influences also the optical cross section spectra obtained as a result of the OSL curve decomposition.

  1. State of art: Optically stimulated luminescence dosimetry – Frontiers of future research

    International Nuclear Information System (INIS)

    Yukihara, Eduardo G.; McKeever, Stephen W.S.; Akselrod, Mark S.

    2014-01-01

    Since the commercial adoption of the optically stimulated luminescence (OSL) technique in dosimetry, almost 20 years ago, we have seen major advances in the deployment of OSL dosimeters in different areas, including personal, medical, and space dosimetry. The objective of this paper is to provide a critical overlook at the OSL technique from three different points of view: strengths, challenges and opportunities. We discuss factors that made the OSL technique successful: its simplicity, accuracy, wide dynamic range of measured dose, ease for automation, re-read capability, ability to perform imaging, and the availability of diverse instruments and materials. We look into problems that were overcome and others that remain in several areas of new applications into which OSL has expanded in the past 10 years, such as medical, space, neutron and accident dosimetry. Finally, we discuss unexplored possibilities, new driving forces, and open questions. We hope the broad overview presented here will encourage more discussion and stimulate the research that will advance our fundamental understanding of the OSL process. - Highlights: • Critical overlook of the OSL technique is presented. • Factors that made the OSL technique successful are discussed. • New applications in medical, space and accident dosimetry are discussed. • Unexplored possibilities, new driving forces, and open questions are presented

  2. Utilisation of OSL from table salt in retrospective dosimetry

    International Nuclear Information System (INIS)

    Fujita, Hiroki; Jain, Mayank; Murray, Andrew S.

    2011-01-01

    Common salt (NaCl) has previously been suggested for use in dose estimation in accident dosimetry. In this study, we investigated the optically stimulated luminescence (OSL) and violet thermoluminescence (VTL) characteristics of 'Aji-Shio' (Ajinomoto), a Japanese commercial salt. A comparison of OSL and TL signals allowed identification of common source traps. The initial OSL signal contained a dominant thermally unstable component, which necessitated prior heat treatment. Based on these luminescence characteristics, a single-aliquot regenerative-dose (SAR) OSL protocol was modified and tested. The protocol worked very well for six types of salt, but not for four other types of salt. A minimum detection limit of ∼15 mGy was estimated using the OSL protocol; this is lower than the value obtained from other forms of OSL retrospective dosimetry and lower than that obtained using electron spin resonance (ESR) dosimetry. It was concluded that the OSL from Japanese commercial salt could be used successfully to derive precise estimates of accident dose. (author)

  3. Optically stimulated luminescence of Tb{sup 3+}/Sm{sup 3+} doubly doped K{sub 2}YF{sub 5} single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, L.; Marcazzo, J.; Santiago, M.; Caselli, E. [Universidad Nacional del Centro de la Provincia de Buenos Aires, Instituto de Fisica Arroyo Seco, Gral. Pinto 399, B7000GHG, Tandil (Argentina); Khaidukov, N. M., E-mail: jmarcass@exa.unicen.edu.ar [Kurnakov Institute of General and Inorganic Chemistry, RAS, Leninskii Prospekt 31, 119991 Moscow (Russian Federation)

    2014-08-15

    In this work optically stimulated luminescence (OSL) properties of K{sub 2}YF{sub 5} crystals doubly doped with Tb{sup 3+} and Sm{sup 3+} ions have been investigated for the first time. OSL responses for different dopant concentration and for optical stimulation with different wavelengths have been analyzed for each compound. Dosimetric properties of the most efficient composition, namely, K{sub 2}YF{sub 5}:1.0 at.% Tb{sup 3+}; 1.0 at.% Sm{sup 3+}, have been studied. Finally, the possible application of this single crystal as OSL dosimeter has been evaluated. (Author)

  4. Temperature dependence of OSL decay curves: Experimental and theoretical aspects

    DEFF Research Database (Denmark)

    McKeever, S.W.S.; Bøtter-Jensen, L.; Agersnap Larsen, N.

    1997-01-01

    ; (2) thermally assisted optical stimulation; (3) thermal quenching; and (4) localized donor-acceptor type recombination. Experimental OSL data from natural quartz and feldspars, stimulated with both green and infra-red light, are examined in the light of the theoretical considerations. (C) 1997...

  5. Thermally and optically stimulated luminescence of AlN-Y2O3 ceramics after ionising irradiation

    DEFF Research Database (Denmark)

    Trinkler, L.; Bos, A.J.J.; Winkelman, A.J.M.

    1999-01-01

    , an essential drawback of AlN-Y2O3 is its high fading rate. Special attention has been focused on understanding and improving the fading properties. In particular, the influence of the ceramics production conditions and the additive concentration on the fading rate have been studied. Experimental results......Thermally (TL) and optically stimulated luminescence (OSL) were studied in AlN-Y2O3 ceramics after irradiation with ionising radiation. The extremely high TL sensitivity (approximately 60 times the sensitivity of LiF:Mg,Tl (TLD-100)) makes AlN-Y2O3 ceramics attractive as a TLD material. However...... on spectral properties and thermal evolution of OSL are also presented. The stimulation spectrum covers the spectral range from green to infrared light. A combination of thermal and optical stimulation allowed a correlation to be found between parameters of OSL and TL after the same irradiation dose...

  6. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    International Nuclear Information System (INIS)

    Kaur, H; Kumar, S; Sarkar, B; Ganesh, T; Giri, U; Jassal, K; Rathinamuthu, S; Gulia, G; Gopal, V; Mohanti, B; Munshi, A

    2016-01-01

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm"2 size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

  7. Optically stimulated luminescence in x-ray irradiated xSnO-(25-x)SrO-75B2O3 glass

    Science.gov (United States)

    Nanto, H.; Nakagawa, R.; Takei, Y.; Hirasawa, K.; Miyamoto, Y.; Masai, H.; Kurobori, T.; Yanagida, T.; Fujimoto, Y.

    2015-06-01

    An intense optically stimulated luminescence (OSL) was observed, for the first time, in x-ray irradiated xSnO-(25-x)SrO-75B2O3 glass. It was found that the peak wavelength of OSL emission spectrum and its stimulation spectrum is about 400 nm and 600 nm, respectively. The OSL intensity is depended on the SnO contents (x=0.05-1.5) and the most intense OSL was observed in 1.0 mol% SnO doped glass. It was found that the OSL intensity is increased with increasing x-ray absorbed dose. Fairly good fading characteristics were observed in the x-ray irradiated glass, showing that this glass is useful as a candidate for OSL sensor materials for ionizing radiation monitoring.

  8. Exploring procedures for the rapid assessment of optically stimulated luminescence range-finder ages

    International Nuclear Information System (INIS)

    Roberts, Helen M.; Durcan, Julie A.; Duller, Geoff A.T.

    2009-01-01

    Optically stimulated luminescence (OSL) dating of sediments is a lengthy, labour-intensive, and time-consuming procedure. However, in some situations a rough approximation of the OSL age is all that is necessary e.g. for a pilot field campaign, to plan a sampling strategy, or to determine the resolution required for a dating campaign. Thus, it would be useful to establish an approximate OSL age without the lengthy and involved processes normally used. This paper explores how the standard procedures involved in OSL age determinations can be simplified to yield range-finder ages. Three areas are examined, namely, laboratory preparation, D e estimation, and dose-rate determination. The consequences of circumventing some of the preparation and measurement steps of conventional OSL dating are examined for a variety of sediments, by comparing the OSL range-finder ages to those obtained using full quartz OSL preparation and measurement procedures.

  9. Optically stimulated luminescence of ZnO obtained by thermal treatment of ZnS chemically synthesized

    International Nuclear Information System (INIS)

    Cruz V, C.; Burruel I, S.E.; Orante B, V.R.; Grijalva M, H.; Perez S, R.; Bernal, R.

    2005-01-01

    In this work, we report the optically stimulated luminescence (OSL) dosimetry of new nano phosphors of ZnO obtained by thermal annealing of chemically synthesized ZnS powder. The synthesized ZnS nano powder was compressed in order to form pellet shaped pellets, which were afterwards subjected to a thermal annealing at 700 C during 24 h under air atmosphere. X-ray diffraction (XRD) patterns and energy-disperse X-ray Spectrometry (EDS) analyses confirmed the transformation of ZnS to ZnO. Samples were exposed to several doses of beta radiation up to 600 Gy, and the optically stimulated luminescence with 470 nm wavelength light was recorded as a function of dose. The intensity of the OSL signal increases by increasing dose, for what it is concluded that these new phosphor materials are suitable to be used in optically stimulated luminescence dosimetry. (Author)

  10. A fiber-dosimetry method based on OSL from Al2O3:C for radiotherapy applications

    International Nuclear Information System (INIS)

    Gaza, R.; McKeever, S.W.S.; Akselrod, M.S.; Akselrod, A.; Underwood, T.; Yoder, C.; Andersen, C.E.; Aznar, M.C.; Marckmann, C.J.; Boetter-Jensen, L.

    2004-01-01

    We describe a high-sensitivity, fiber-optic dosimetry system based on optically stimulated luminescence (OSL) and radioluminescence from Al 2 O 3 :C single-crystal fibers (detectors). The detectors are coupled to a fiber optic delivery system and OSL from the detector is stimulated via the optical fiber cable using light from a Nd:YAG laser. The OSL is guided back along the same fiber and is detected by a photomultiplier tube. The Al 2 O 3 :C detectors are small and demonstrate high sensitivity with a large signal-to-noise ratio. We describe two modes of operation of the system and discuss algorithms that provide accurate estimation of dose rate and integrated dose in near real time. The system is free from magnetic and electrical interference, and is designed for use in several forms of radiotherapy, including in vitro brachytherapy source calibration, and in vivo dosimetry during patient treatment

  11. Natural and laboratory TT-OSL dose response curves: Testing the lifetime of the TT-OSL signal in nature

    International Nuclear Information System (INIS)

    Chapot, M.S.; Roberts, H.M.; Duller, G.A.T.; Lai, Z.P.

    2016-01-01

    This study compares natural and laboratory generated thermally transferred optically stimulated luminescence (TT-OSL) dose response curves (DRCs) for fine-grain quartz extracts from the Luochuan loess section in central China. Both DRCs saturate at high doses relative to the quartz OSL signal; the natural TT-OSL DRC saturates at about 2200 Gy and laboratory DRCs saturate at about 2700 Gy. However, the natural and laboratory TT-OSL DRCs deviate from one another at circa 150 Gy resulting in TT-OSL equivalent dose underestimation relative to palaeodoses expected from dose rates and independent age control. The lifetime of the TT-OSL signal at 10 °C, calculated from values of trap parameters E and s, is compared against the value for lifetime of the TT-OSL signal in nature at average burial temperature as determined from the age underestimation caused by deviation of the natural and laboratory generated DRCs. These two independent assessments of TT-OSL signal lifetime at Luochuan give similar values, suggesting that laboratory measurements of thermal stability reflect natural burial lifetimes and can potentially be used to correct TT-OSL ages for the difference between natural and laboratory dose response curves. - Highlights: • Natural and laboratory TT-OSL DRCs deviate at ∼150 Gy but saturate at higher doses. • TT-OSL signal lifetime at 10 °C calculated from measured E and s values is ∼180 ka. • TT-OSL signal lifetime at Luochuan estimated from the DRCs' deviation is ∼175 ka. • Natural and laboratory TT-OSL DRC deviation may be caused by low thermal stability. • Laboratory measurements of signal lifetime may be able to correct old TT-OSL ages.

  12. Further investigations into pulsed optically stimulated luminescence from feldspars using blue and green light

    DEFF Research Database (Denmark)

    Ankjærgaard, Christina; Jain, Mayank; Kalchgruber, R.

    2009-01-01

    The purpose of this paper is to investigate characteristics of luminescence signals resulting from pulsed optical stimulation of feldspars and thereby to understand the underlying processes giving rise to the signal. Fourteen different feldspar specimens were investigated using time-resolved opti......The purpose of this paper is to investigate characteristics of luminescence signals resulting from pulsed optical stimulation of feldspars and thereby to understand the underlying processes giving rise to the signal. Fourteen different feldspar specimens were investigated using time...... suggests that the TR-OSL signal decay is governed by the recombination process and not by the excited state lifetime. Furthermore data from the TR-OSL signal dependence on stimulation time and preheat temperature suggest that the recombination process may not be a sum of exponentials, although the model...... cannot be rejected definitively....

  13. On optically stimulated luminescence properties of household salt as a retrospective dosemeter

    International Nuclear Information System (INIS)

    Timar-Gabor, A.; Trandafir, O.

    2013-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) in the UV (270-370 nm) spectral region have been investigated for five types of table salt (NaCl) available in Romanian supermarkets with a view to applying them in retrospective dosimetry. The salt samples gave bright TL signals with two main peaks at ∼ 100 deg. C and at 300 or 260 deg. C, depending on the origin of the salt and bright OSL signals under continuous stimulation with blue light. The OSL signal (stimulated at 100 deg. C after a pre-heat of 10 s at 150 deg. C) was used for investigations in a standard multiple aliquot procedure. The dose- response was found to be linear in the dose range investigated (up to ∼ 100 mGy) and the lower limit of detection for the samples varied from ∼ 0.01 to 14 mGy. These characteristics, along with the widespread abundance and low cost of household salt, confirm its potential as a retrospective dosemeter. (authors)

  14. Characterization of Al{sub 2}O{sub 3}:C dosemeters for photon dosimetry using OSL technique; Caracterizacao de dosimetros de Al{sub 2}O{sub 3}:C para dosimetria de fotons utilizando a tecnica OSL

    Energy Technology Data Exchange (ETDEWEB)

    Villani, D.; Almeida, S.B.; Campos, L.L., E-mail: dvillani@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2016-07-01

    The optically stimulated dosimetry (OSL) has gained prominence in clinical and academic applications in Brazil. In this paper, we present results of the characterization OSL dosimeters Al{sub 2}O{sub 3}:C (TLD-500) manufactured by Rexon™ Components and TLD Systems in a RISØ reader, model TL/OSL-DA-20 for dosimetry of high-energy photon beams. All reader parameters, and its variations were evaluated. (author)

  15. Optically stimulated luminescence of natural NaCl mineral from Dead Sea exposed to gamma radiation

    International Nuclear Information System (INIS)

    Roman L, J.; Cruz Z, E.; Pina L, Y. I.; Marcazzo, J.

    2016-10-01

    Luminescence properties such as radioluminescence, thermoluminescence and optically stimulated luminescence have been studied on natural sodium chloride (NaCl) for dosimetric purposes in retrospective dosimetry (Timar-Gabor et al., 2013; Druzhyna et al., 2016). In this work, the optically stimulated luminescence (Cw-OSL) emissions of natural salt minerals, collected from Dead Sea in summer of 2015, were studied. The Cw-OSL dose response of natural salt was analyzed in the range between 0.2 and 10 Gy gamma dose of "6"0Co. Samples exposed at 3 Gy exhibited good repeatability with a variation coefficient of 4.6%. The thermal stability of the Cw-OSL response was analyzed to different temperatures from 50 up to 250 degrees Celsius using a heating rate of 5 degrees Celsius. The results showed that the natural Dead Sea salt minerals could be applied as natural dosimeter of gamma radiation. (Author)

  16. Optically stimulated luminescence of natural NaCl mineral from Dead Sea exposed to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Roman L, J.; Cruz Z, E. [UNAM, Instituto de Ciencias Nucleares, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Pina L, Y. I. [UNAM, Facultad de Ciencias, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Marcazzo, J., E-mail: jesus.roman@nucleares.unam.mx [Instituto de Fisica Arroyo Seco - UNICEN, Pinto 399, 7000 Tandil (Argentina)

    2016-10-15

    Luminescence properties such as radioluminescence, thermoluminescence and optically stimulated luminescence have been studied on natural sodium chloride (NaCl) for dosimetric purposes in retrospective dosimetry (Timar-Gabor et al., 2013; Druzhyna et al., 2016). In this work, the optically stimulated luminescence (Cw-OSL) emissions of natural salt minerals, collected from Dead Sea in summer of 2015, were studied. The Cw-OSL dose response of natural salt was analyzed in the range between 0.2 and 10 Gy gamma dose of {sup 60}Co. Samples exposed at 3 Gy exhibited good repeatability with a variation coefficient of 4.6%. The thermal stability of the Cw-OSL response was analyzed to different temperatures from 50 up to 250 degrees Celsius using a heating rate of 5 degrees Celsius. The results showed that the natural Dead Sea salt minerals could be applied as natural dosimeter of gamma radiation. (Author)

  17. High resolution optically stimulated luminescence dating of a sediment core from the southwestern Sea of Okhotsk

    DEFF Research Database (Denmark)

    Sugisaki, S.; Buylaert, J. P.; Murray, A. S.

    2012-01-01

    (D-e), with stimulation by both infrared and blue light. The suitability of the measurement procedure was confirmed using dose recovery tests. A high resolution record (similar to 2 OSL ages/m) identified clear sedimentation rate changes down the core. The OSL ages are significantly dependent......Optically stimulated luminescence (OSL) dating is now widely accepted as a chronometer for terrestrial sediment. More recently, it has been suggested that OSL may also be useful in the dating of deep-sea marine sediments. In this paper, we test the usefulness of high resolution quartz OSL dating...... in application to a 19 m marine sediment core (MR0604-PC04A) taken from the southwestern Sea of Okhotsk, immediately to the north of Hokkaido, Japan. Fine-grained quartz (4 to 11 mu m) was chosen as the dosimeter, and a single-aliquot regenerative-dose protocol was used for the determination of equivalent dose...

  18. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

    Science.gov (United States)

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-01-01

    For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.

  19. OSL-thermochronometry using bedrock quartz: a note of caution

    DEFF Research Database (Denmark)

    Guralnik, B.; Ankjærgaard, Christina; Jain, Mayank

    2015-01-01

    Optically stimulated luminescence (OSL) thermochronometry is an emerging application, whose capability to record sub-Million-year thermal histories is of increasing interest to a growing number of subdisciplines of Quaternary research. However, several recent studies have encountered difficulties......, and may hamper successful OSL dating. Furthermore, even when the desirable signal is present, its concentration might be indistinguishable from its environmental steady-state prediction, thus preventing its conversion to a cooling or heating history. We explore the saturation properties and the thermal...

  20. Optically stimulated luminescence dosimetry performance of natural Brazilian topaz exposed to beta radiation

    International Nuclear Information System (INIS)

    Bernal, R.; Souza, D. N.; Valerio, M. E. G.; Cruz-Vazquez, C.; Barboza-Flores, M.

    2006-01-01

    Optically stimulated luminescence (OSL) has become the technique of choice in many areas of dosimetry. Natural materials like topaz are available in large quantities in Brazil and other countries. They have been studied to investigate the possibility of use its thermoluminescence (TL) properties for dosimetric applications. In this work, we investigate the possibility of utilising the OSL properties of natural Brazilian topaz in dosimetry. Bulk topaz samples were exposed to doses up to 100 Gy of beta radiation and the integrated OSL as a function of the dose showed linear behaviour. The fading occurs in the first 20 min after irradiation but it is <6% of the integrated OSL measured shortly after exposure. We conclude that natural colourless topaz is a very suitable phosphor for OSL dosimetry. (authors)

  1. Optically stimulated luminescence characteristics of natural and doped quartz and alkali feldspars

    Energy Technology Data Exchange (ETDEWEB)

    Huett, G.; Jaek, I.; Brodski, L. [Institute of Geology at Tallinn Technical University, Tallinn (Estonia); Vasilchenko, V. [Institute of Experimental Physics and Technology of Tartu University, Tartu (Estonia)

    1999-05-01

    Natural alkali feldspars and quartz were doped by Tl and Cu by thermodiffusion and electrodiffusion technology. As a result of doping, intensive UV emission bands were created. The OSL stimulation spectra of irradiated natural and doped quartz and alkali feldspars were measured in the span of 400-1300 nm using UV emission of Tl at 280 nm and of Cu at 380 nm. One-trap centre conception was confirmed for high-temperature palaeodosimetrical TL peaks and OSL stimulation spectrum bands: for alkali feldspars at 880 and 420 nm and visible region of the spectrum for quartz. A thermooptical mechanism of the optical depopulation of the corresponding trap is confirmed in alkali feldspars, but there is no evidence for processes of this kind in quartz. An analogy between the physical background of OSL properties of both minerals is discussed.

  2. Optically stimulated luminescence characteristics of natural and doped quartz and alkali feldspars

    International Nuclear Information System (INIS)

    Huett, G.; Jaek, I.; Brodski, L.; Vasilchenko, V.

    1999-01-01

    Natural alkali feldspars and quartz were doped by Tl and Cu by thermodiffusion and electrodiffusion technology. As a result of doping, intensive UV emission bands were created. The OSL stimulation spectra of irradiated natural and doped quartz and alkali feldspars were measured in the span of 400-1300 nm using UV emission of Tl at 280 nm and of Cu at 380 nm. One-trap centre conception was confirmed for high-temperature palaeodosimetrical TL peaks and OSL stimulation spectrum bands: for alkali feldspars at 880 and 420 nm and visible region of the spectrum for quartz. A thermooptical mechanism of the optical depopulation of the corresponding trap is confirmed in alkali feldspars, but there is no evidence for processes of this kind in quartz. An analogy between the physical background of OSL properties of both minerals is discussed

  3. Emergency OSL dosimetry with commonplace materials

    International Nuclear Information System (INIS)

    Sholom, S.; McKeever, S.W.S.

    2014-01-01

    Several commonplace materials were studied as possible emergency optically stimulated luminescence (OSL) dosimeters. The materials included: paper currency (banknotes) and coins of different denomination and from different countries; plastic cards of different types (credit and debit cards, driver's license cards, membership cards, etc.), parts and details of clothing and shoes as well as samples of different fabrics. The samples displayed significant variability in their OSL properties. They differed in the intensity of the initial ‘native’ signal; the bleaching time of the OSL signal; the sensitivity to light of different wavelengths; the fading rate of OSL signals, etc. Procedures of OSL analysis were proposed to account for this variety. Values of the minimum measurable dose (MMD) were below 2 Gy for most tested samples if OSL measurements were conducted within one week of exposure and the samples were kept in dark since exposure (except samples of shoes that were kept under environmental light). The OSL signals in banknotes appear to originate from compounds containing aluminum, silicon, calcium and titanium – these elements were detected using X-ray microanalysis. For coins, the source of the OSL signals is speculated to be small particles of quartz, which were detected on the coins' surfaces. The X-ray microanalysis spectra from fabrics and shoes revealed sodium, aluminum, titanium, iron and nickel as elements that appeared to be responsible for the radiation sensitivity of those samples. It was concluded that, under certain constrained circumstances, paper and metallic money, personal plastic cards, clothing and shoes could be used as emergency OSL dosimeters in triage applications. - Highlights: • Money, plastic cards, clothing and shoes were studied as emergency OSL dosimeters. • Values of the minimum measurable doses were below 2 Gy for most tested samples. • Tested materials could be used as emergency OSL dosimeters in triage applications

  4. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, H; Kumar, S; Sarkar, B; Ganesh, T; Giri, U; Jassal, K; Rathinamuthu, S; Gulia, G; Gopal, V; Mohanti, B; Munshi, A [Fortis Memorial Research Institute, Gurgaon, Haryana (India)

    2016-06-15

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

  5. Radiation dose response correlation between thermoluminescence and optically stimulated luminescence in quartz

    International Nuclear Information System (INIS)

    Oniya, E.O.; Polymeris, G.S.; Tsirliganis, N.C.; Kitis, G.

    2012-01-01

    The fast, linearly modulated optically stimulated luminescence (LM-OSL) component in quartz is the main dosimetric signal used for the dating applications of this material. Since the blue light stimulation (470 nm, 40 mW cm −2 ) time needed to obtain the fast LM-OSL component is less than 50 s the electron trapping levels responsible for it are still highly populated. In this way an active radiation history is created which could play an important role in the dosimetric characteristics of the fast OSL signal. In the present work the dose response behavior of the fast OSL signal is investigated in quartz samples with an annealed radiation history and quartz samples possessing an artificial radiation history. A computerized curve de-convolution analysis of the LM-OSL curves for 50 s stimulation time showed that it consists of three individual OSL components. The faster component C 1 with peak maximum time around 5 s has a linear dose response in virgin samples, which turns to a slight superlinearity as a function of the artificial radiation history. On the other hand the component C 2 with peak maximum time at 12 s is slightly superlinear which turns into strong superlinearity as a function of artificial radiation history. Finally, component C 3 with peak maximum time at about 45 s is strongly superlinear for both virgin samples and as a function of artificial radiation history. The implications to practical application are discussed. - Highlights: ► The fast OSL component consists of three components. ► The linearity of first fast component does not depend on radiation history. ► The linearity of second and third components depend on radiation history. ► The TL between 180 and 300 °C is the major source of OSL.

  6. A low-cost personal dosemeter based on optically stimulated luminescence (OSL) of common household salt (NaCl)

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Bulánek, Boris; Judas, Libor

    2016-01-01

    Salt represents a radiation sensitive material that can be used for dosimetry. The objective of this experimental study was to test a low-cost salt dosemeter that was designed for personnel that are not radiation workers, but can operate in low probability events resulting in a serious external radiation exposure. The dosemeter is based on use of optically stimulated luminescence (OSL) of a common household salt. Attention was concentrated on its energy and angular responses. The dosemeter was fixed to the ICRU slab phantom and irradiated by photons of reference radiation qualities (ISO 4037-1) with mean energies between 33 and 1250 keV. Angular response was investigated for angles of incidence from 0° to 80° for radiation qualities of N-150 (∼118 keV) and S-Cs (∼662 keV). Single-Aliquot Regenerative-dose analytical protocol was employed for dose reconstruction. The results were evaluated with respect to H_p(10) measurement. The salt dosemeter can provide reliable or reasonably conservative H_p(10) estimates in radiation fields where photon energies > 100 keV predominate, radiation incidence angles are from 0° to 80° and also for rotational geometry. Furthermore, a personal dose reconstruction trial was demonstrated. Relative deviation between the measured and reference H_p(10) values was 5.5%. A practical disadvantage of the method is the more demanding analytical protocol. - Highlights: • Common salt has a considerable potential for dosimetry based on use of OSL. • A simple salt personal dosemeter was designed and tested. • Photon energy and angular responses were satisfactory for purposes of accidental dosimetry. • Dose reconstruction trial proved the potential for reliable estimate of personal doses.

  7. A reusable OSL-film for 2D radiotherapy dosimetry

    Science.gov (United States)

    Wouter, Crijns; Dirk, Vandenbroucke; Paul, Leblans; Tom, Depuydt

    2017-11-01

    Optical stimulated luminescence (OSL) combines reusability, sub-mm resolution, and a linear dose response in a single radiation detection technology. Such a combination is currently lacking in radiotherapy dosimetry. But OSL-films have a strong energy dependent response to keV photons due to a relative high effective atomic number (Z eff). The current work studied the applicability of a 2D OSL-film with a reduced Z eff as (IMRT/VMAT) dosimeter. Based on their commercial OSL-film experience, Agfa Healthcare N.V. produced a new experimental OSL-film for RT dosimetry. This film had a lower effective atomic number compared to the films used in radiology. Typical 2D dosimeter requirements such as uniformity, dose response, signal stability with time, and angular dependence were evaluated. Additionally, the impact of a possible residual energy dependence was assessed for the infield as well as the out-of-field region of both static beams and standard intensity modulated patterns (chair and pyramid). The OSL-film’s reusable nature allowed for a film specific absolute and linear calibration including a flood-field uniformity correction. The OSL-film was scanned with a CR-15X engine based reader using a strict timing (i.e. 4 min after ‘beam on’ or as soon as possible) to account for spontaneous recombination. The OSL-film had good basic response properties: non-uniformities  ⩽2.6%, a linear dose response (0-32 Gy), a linear signal decay (0.5% min-1) over the 20 min measured, and limited angular dependence  ⩽2.6%. Due to variations of the energy spectrum, larger dose differences were noted outside the central region of the homogenous phantom and outside both static and IMRT fields. However, the OSL-film’s measured dose differences of the IMRT patterns were lower than those of Gafchromic EBT measurements ([-1.6%, 2.1%] versus [-2.9%, 3.6%]). The current OSL-film could be used as a reusable high resolution dosimeter with read-out immediately after

  8. Optical fibre dosemeter systems for clinical applications based on radioluminescence and optically stimulated luminescence from Al2O3:C

    DEFF Research Database (Denmark)

    Marckmann, C.J.; Andersen, C.E.; Aznar, M.C.

    2006-01-01

    Optical fibre dosemeter systems based on radioluminescence and optically stimulated luminescence (OSL) from carbon-doped aluminium oxide (Al2O3:C) crystals were developed for in vivo real-time dose rate and absorbed dose measurements in radiotherapy and mammography. A technique was also developed...... for making ultra-small dosemeter probes that can easily be placed inside patients in radiation treatment. These probes have shown excellent properties in both head and neck intensity-modulated radiation therapy treatment and in mammography. The dose-response of the OSL signal for the new optical fibre...

  9. BeOSL system for personal dosimetry : dosimetric characteristics and practical application; Sistema BeOSL para dosimetria personal : caracteristicas dosimetricas y la aplicacion practica

    Energy Technology Data Exchange (ETDEWEB)

    Mende, E. [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, Working Group Engineering, D-85764 Neuherberg (Germany)

    2015-10-15

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  10. Emergency dose estimation using optically stimulated luminescence from human tooth enamel

    International Nuclear Information System (INIS)

    Sholom, S.; DeWitt, R.; Simon, S.L.; Bouville, A.; McKeever, S.W.S.

    2011-01-01

    Human teeth were studied for potential use as emergency Optically Stimulated Luminescence (OSL) dosimeters. By using multiple-teeth samples in combination with a custom-built sensitive OSL reader, 60 Co-equivalent doses below 0.64 Gy were measured immediately after exposure with the lowest value being 27 mGy for the most sensitive sample. The variability of OSL sensitivity, from individual to individual using multiple-teeth samples, was determined to be 53%. X-ray and beta exposure were found to produce OSL curves with the same shape that differed from those due to ultraviolet (UV) exposure; as a result, correlation was observed between OSL signals after X-ray and beta exposure and was absent if compared to OSL signals after UV exposure. Fading of the OSL signal was 'typical' for most teeth with just a few of incisors showing atypical behavior. Typical fading dependences were described by a bi-exponential decay function with 'fast' (decay time around of 12 min) and 'slow' (decay time about 14 h) components. OSL detection limits, based on the techniques developed to-date, were found to be satisfactory from the point of view of medical triage requirements if conducted within 24 h of the exposure.

  11. Emergency dose estimation using optically stimulated luminescence from human tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Sholom, S., E-mail: sergey.sholom@okstate.edu [Oklahoma State University, Stillwater, OK (United States); DeWitt, R. [Oklahoma State University, Stillwater, OK (United States); Simon, S.L.; Bouville, A. [National Cancer Institute, National Institutes of Health, Bethesda, MD (United States); McKeever, S.W.S. [Oklahoma State University, Stillwater, OK (United States)

    2011-09-15

    Human teeth were studied for potential use as emergency Optically Stimulated Luminescence (OSL) dosimeters. By using multiple-teeth samples in combination with a custom-built sensitive OSL reader, {sup 60}Co-equivalent doses below 0.64 Gy were measured immediately after exposure with the lowest value being 27 mGy for the most sensitive sample. The variability of OSL sensitivity, from individual to individual using multiple-teeth samples, was determined to be 53%. X-ray and beta exposure were found to produce OSL curves with the same shape that differed from those due to ultraviolet (UV) exposure; as a result, correlation was observed between OSL signals after X-ray and beta exposure and was absent if compared to OSL signals after UV exposure. Fading of the OSL signal was 'typical' for most teeth with just a few of incisors showing atypical behavior. Typical fading dependences were described by a bi-exponential decay function with 'fast' (decay time around of 12 min) and 'slow' (decay time about 14 h) components. OSL detection limits, based on the techniques developed to-date, were found to be satisfactory from the point of view of medical triage requirements if conducted within 24 h of the exposure.

  12. Development of optically stimulated luminescence technology for personnel monitoring applications at Bhabha Atomic Research Centre

    International Nuclear Information System (INIS)

    Kulkarni, M.S.

    2012-01-01

    The popularity of optically stimulated luminescence (OSL) technology in the radiation dosimetry applications, in general, and personnel and environmental monitoring, in particular, has driven investigation and developmental programme using OSL technique for a viable system for personnel monitoring at Bhabha Atomic Research Centre. The OSL related phosphor materials and instrumentation development has a very recent history in Bhabha Atomic Research Centre. The OSL technique is more versatile and easy to use than thermoluminescence (TL) technique. The X- and gamma ray (both high and low energy) photons and beta particles can be measured with OSL technique. In the OSL technique, the phosphor (say á- Ai 2 O 3 :C) is optically stimulated by blue/green light and the resulting light emitted from Al 2 O 3 :C (410-420 nm) is measured and correlated to the amount of radiation exposure. For a fixed stimulation intensity, the emitted blue light from the Al 2 O 3 :C dosimeter is proportional to the radiation exposure. The OSL technology is being increasingly used in several applications in external radiation dosimetry, in-vivo medical dosimetry in radiotherapy, in-situ, long-term monitoring system for radioactive contaminants, geological and archaeological dating of sediments, etc. For the success of OSL technology for large scale countrywide personnel monitoring program, indigenous development of dosimetric grade sensitive detector material was a key issue. Therefore, since 2002, efforts were directed towards the development of OSL phosphors (like aluminum oxide doped with carbon, á- Al 2 O 3 :C) and related instrumentation. To begin with, simple low cost OSL readers were developed using blue (470 nm) and green (530 nm) LED clusters. New techniques were developed for the preparation of dosimetric grade á- Ai 2 O 3 :C and other OSL phosphors. With the success in the development of indigenous technique for the large scale preparation of á- Al 2 O 3 :C phosphor, a four

  13. Tl and OSL on diopside crystal

    International Nuclear Information System (INIS)

    Cano, N.F.; Watanabe, S.; Mittani, J.C.R.; Yukihara, E.G.

    2006-01-01

    The diopside with chemical composition CaMgSi 2 O 6 is part of an important solid solution series of the pyroxene group. The mineral is commonly found in meteorites and it is an important rock forming mineral of medium and high grade metamorphic rocks which are rich in calcium. In the bibliography it is possible to found several studies on electron spin resonance (ESR), reflectance, etc. but not on thermoluminescence (TL) or optically stimulated luminescence (OSL). In the present work we studied diopside TL and OSL behaviour on natural and natural irradiated samples. The sample used in our study is a white coloured diopside provided by Mineracao Sao Judas located in Sao Paulo, Brazil. The X-Ray Fluorescence technique has shown high concentrations of SiO 2 (55.81 % mol), CaO (23.47 % mol), MgO (18.03 % mol), Al 2 O 3 (1.56 % mol), Fe 2 O 3 (0.53 % mol), K 2 O (0.44 % mol), TiO 2 (0.065 % mol), P 2 O 5 (0.026 % mol), and MnO (0.013 % mol). TL measurements on natural samples show four TL peaks at 160, 260, 360, and 450 C. After beta-irradiation an increment mainly in the low temperature peaks is observed. As for OSL measurements, low OSL signal was observed on natural samples using blue light stimulation and UV detection. The intensity of the signal was observed to increase with the irradiation dose. (Author)

  14. Neutron dosimetry using optically stimulated luminescence

    International Nuclear Information System (INIS)

    Miller, S.D.; Eschbach, P.A.

    1991-06-01

    The addition of thermoluminescent (TL) materials within hydrogenous matrices to detect neutron-induced proton recoils for radiation dosimetry is a well-known concept. Previous attempts to implement this technique have met with limited success, primarily due to the high temperatures required for TL readout and the low melting temperatures of hydrogen-rich plastics. Research in recent years at Pacific Northwest laboratories (PNL) has produced a new Optically Stimulated Luminescence (OSL) technique known as the Cooled Optically Stimulated Luminescence (COSL) that offers, for the first time, the capability of performing extremely sensitive radiation dosimetry at low temperatures. In addition to its extreme sensitivity, the COSL technique offers multiple readout capability, limited fading in a one-year period, and the capability of analyzing single grains within a hydrogenous matrix. 4 refs., 10 figs

  15. Does deposition depth control the OSL bleaching of fluvial sediment?

    NARCIS (Netherlands)

    Cunningham, A. C.; Wallinga, J.; Hobo, N.; Versendaal, A. J.; Makaske, B.; Middelkoop, H.

    2014-01-01

    The Optically Stimulated Luminescence (OSL) signal from fluvial sediment often contains a remnant from the previous deposition cycle, leading to a partially bleached equivalent-dose distribution. Although identification of the burial dose is of primary concern, the degree of bleaching could

  16. Aluminum Nitride Ceramic as an Optically Stimulable Luminescence Dosimeter Plate

    Directory of Open Access Journals (Sweden)

    Go Okada

    2016-04-01

    Full Text Available Photostimulable storage phosphors have been used in a wide range of applications including radiation measurements in one- and two-dimensional spaces, called point dosimetry and radiography. In this work, we report that an aluminum nitride (AlN ceramic plate, which is practically used as a heat sink (SHAPAL®, Tokuyama Corp., Yamaguchi, Japan, shows good optically-stimulated luminescence (OSL properties with sufficiently large signal and capability for imaging applications, and we have characterized the AlN plate for OSL applications. Upon interaction with X-rays, the sample color turns yellowish, due to a radiation-induced photoabsorption band in the UV-blue range below ~500 nm. After irradiating the sample with X-rays, an intense OSL emission can be observed in the UV (360 nm spectral region during stimulation by red light. Although our measurement setup is not optimized, dose detection was confirmed as low as ~3 mGy to over 20 Gy. Furthermore, we have successfully demonstrated that the SHAPAL® AlN ceramic plate has great potential to be used as an imaging plate in radiography.

  17. Fiber-optic, real-time dosimeter based on optically stimulated luminescence of Al2O3:C and KBr:Eu for potential use in the radiotherapy of cancer

    International Nuclear Information System (INIS)

    Gaza, Razvan

    2004-01-01

    This thesis describes a single-fiber dosimetry system based on optically stimulated luminescence (OSL) of artificially grown single crystals of Al 2 O 3 :C and KBr:Eu, with potential application in the medical field, especially in radio oncology. Small fiber-shaped dosimeters with dimensions (diameter/length) on the order of 500 μm/5 mm are attached to one end of an optical fiber, resulting in fiber probes with diameters of less than 1 mm and lengths of up to 15 m. The opposite end of the fiber is connected to an OSL reader that contains a stimulation light source (laser) and a photomultiplier tube that is used for luminescence detection. During irradiation, an optomechanical shutter periodically allows laser light to be transmitted down the optical fiber, to stimulate the luminescence response from the dosimeter being irradiated at a remote location. The luminescence measured during each interval of laser stimulation is indicative of the radiation dose absorbed in the dosimeter since the previous stimulation. The integral absorbed dose is obtained via a summation procedure from the measured dose fractions. Several operating procedures and data processing algorithms were developed in order to increase the speed and accuracy of the measurements, and integrated into the software that controls automated operation of the OSL readers. Periodic modulation of the stimulation also allows the OSL signal to be discriminated from background fluorescence, and thus yields measurements that are unaffected by Cerenkov light (the so-called 'stem effect'). Depending on the type of material used, the speed of the measurements, expressed as the time required to estimate an individual dose fraction, can be as short as 67 ms. Integral dose estimates from real-time OSL of Al 2 O 3 :C and KBr:Eu were obtained for water-phantom irradiations performed with medical teletherapy sources, and were found to agree within 3.7% and 2.8%, respectively, with reference measurements from ionization

  18. A single-aliquot regenerative-dose method based on IR (1.49 eV) bleaching of the fast OSL component in quartz

    DEFF Research Database (Denmark)

    Jain, M.; Murray, A.S.; Bøtter-Jensen, L.

    2005-01-01

    In the optically stimulated luminescence (OSL) dating of quartz, the presence of significant medium and slow components in the initial-OSL signal (first 0.8 s or so) can give rise to erroneous dose estimates. Thus it is desirable to develop a dose estimation method that is based on the OSL from t...

  19. Single photon detection and signal analysis for high sensitivity dosimetry based on optically stimulated luminescence with beryllium oxide

    Science.gov (United States)

    Radtke, J.; Sponner, J.; Jakobi, C.; Schneider, J.; Sommer, M.; Teichmann, T.; Ullrich, W.; Henniger, J.; Kormoll, T.

    2018-01-01

    Single photon detection applied to optically stimulated luminescence (OSL) dosimetry is a promising approach due to the low level of luminescence light and the known statistical behavior of single photon events. Time resolved detection allows to apply a variety of different and independent data analysis methods. Furthermore, using amplitude modulated stimulation impresses time- and frequency information into the OSL light and therefore allows for additional means of analysis. Considering the impressed frequency information, data analysis by using Fourier transform algorithms or other digital filters can be used for separating the OSL signal from unwanted light or events generated by other phenomena. This potentially lowers the detection limits of low dose measurements and might improve the reproducibility and stability of obtained data. In this work, an OSL system based on a single photon detector, a fast and accurate stimulation unit and an FPGA is presented. Different analysis algorithms which are applied to the single photon data are discussed.

  20. Remote TL and OSL for asteroid and meteorite study

    International Nuclear Information System (INIS)

    Takaki, Shunji; Ikeya, Motoji; Yamanaka, Chihiro

    1997-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) of the Allende meteorite have been studied using infrared CO 2 laser light as a heat source and He-Ne laser light to excite the material, respectively from a long distance. New techniques of remote TL (R-TL) and remote OSL (R-OSL) have been developed for future remote dating from a long distance in a planetary survey. The upper limits of the distance for R-TL and R-OSL were estimated using the laboratory TL signal of the meteorite peaking at 320 o C: about 400 photons s -1 for the R-TL and 60 photons s -1 for R-OSL at a distance of 1 km using a laser beam with the divergence of 0.1 mrad at powers of 100 and 1 W, respectively. An age limit of 10 5 or 10 6 years due to the signal saturation and the objects heterogeneity, as expected from previous studies, may make the asteroid survey difficult but would still help to investigate the surface activities of icy planets and satellites in outer planet worlds. (author)

  1. Integrated circuits from mobile phones as possible emergency OSL/TL dosimeters

    International Nuclear Information System (INIS)

    Sholom, S.; McKeever, S.W.S.

    2016-01-01

    In this article, optically stimulated luminescence (OSL) data are presented from integrated circuits (ICs) extracted from mobile phones. The purpose is to evaluate the potential of using OSL from components in personal electronic devices such as smart phones as a means of emergency dosimetry in the event of a large-scale radiological incident. ICs were extracted from five different makes and models of mobile phone. Sample preparation procedures are described, and OSL from the IC samples following irradiation using a 90 Sr/ 90 Y source is presented. Repeatability, sensitivity, dose responses, minimum measurable doses, stability and fading data were examined and are described. A protocol for measuring absorbed dose is presented, and it was concluded that OSL from these components is a viable method for assessing dose in the days following a radiological incident. (authors)

  2. Investigation of TL, OSL and PTTL properties of Mg2SiO4:Tb dosimeters

    International Nuclear Information System (INIS)

    Oguz, K. F.; Goekce, M.; Karali, T.; Harmansah, C.

    2010-01-01

    In this study thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of Mg 2 SiO 4 :Tb in the form of sintered pellets were investigated. Mg 2 SiO 4 :Tb is a recently developed dosimetric material which offers high sensitivity for TL and OSL in dosimetric applications. Thermoluminescence glow curve of Tb doped Mg 2 SiO 4 samples show a glow peak at about 200 degree Celsius with two small peaks at about 275 and 330 degree Celsius, respectively. OSL experiments showed that blue light (470 nm) is six times more efficient than green light (532 nm) to stimulate the OSL emission. The aim of this study was to determine the TL and OSL fading properties of Mg 2 SiO 4 : Tb using OSL and TL methods. In addition, PTTL properties of the Mg 2 SiO 4 : Tb was investigated by using blue LEDs, UV lamp and blue laser. Investigations on the fading properties also showed that the TL signal fades % 10 in a period of 1 month and OSL signal fades % 10 in a period of 3 month, which then the signal remains relatively stable for longer periods.

  3. Component resolved bleaching study in natural calcium fluoride using CW-OSL, LM-OSL and residual TL glow curves after bleaching

    International Nuclear Information System (INIS)

    Angeli, Vasiliki; Polymeris, George S.; Sfampa, Ioanna K.; Tsirliganis, Nestor C.; Kitis, George

    2017-01-01

    Natural calcium fluoride has been commonly used as thermoluminescence (TL) dosimeter due to its high luminescence intensity. The aim of this work includes attempting a correlation between specific TL glow curves after bleaching and components of linearly modulated optically stimulated luminescence (LM-OSL) as well as continuous wave OSL (CW-OSL). A component resolved analysis was applied to both integrated intensity of the RTL glow curves and all OSL decay curves, by using a Computerized Glow-Curve De-convolution (CGCD) procedure. All CW-OSL and LM-OSL components are correlated to the decay components of the integrated RTL signal, apart from two RTL components which cannot be directly correlated with either LM-OSL or CW-OSL component. The unique, stringent criterion for this correlation deals with the value of the decay constant λ of each bleaching component. There is only one, unique bleaching component present in all three luminescence entities which were the subject of the present study, indicating that each TL trap yields at least three different bleaching components; different TL traps can indicate bleaching components with similar values. According to the data of the present work each RTL bleaching component receives electrons from at least two peaks. The results of the present study strongly suggest that the traps that contribute to TL and OSL are the same. - Highlights: • A component resolved bleaching study was attempted to CaF_2:N in terms of CW-OSL, LM-OSL and RTL. • Bleaching decay constants originating from different TL peaks yield overlapping values. • Three to five individual components were used in order to describe the bleaching behavior in all luminescence entities. • There is only one, unique bleaching component present in all three luminescence entities.

  4. The correlation of fast OSL component with the TL peak at 3250C in quartz of various origins

    International Nuclear Information System (INIS)

    Kitis, G.; Kiyak, N.; Polymeris, G.S.; Tsirliganis, N.C.

    2010-01-01

    The fast component of the optically stimulated luminescence (OSL) signal in quartz is the basic tool for the optical dating. Its relation with the thermoluminescence (TL) glow-peak at about 325 deg. C is well established for naturally irradiated quartz. This relationship is also an important part of a general model for quartz on which many theoretical simulations of various OSL experimental results have been based. In the present work this relationship is systematically investigated in nine quartz samples of different origin. The linearly modulated OSL (LM-OSL) curves of all quartz samples for stimulation time less than 50 s consists of two components discriminated easily by a computerized curve deconvolution (CCD) analysis. By comparing the un-bleached to the respective bleached TL glow-curve, it is found that the system of these two fast OSL components is directly related with only a small portion of the electron traps responsible for the TL glow-peaks in the temperature region 200-400 0 C. By increasing the stimulation times, besides the two fast components, the medium and the slow components are also obtained. The medium and slow components are clearly related with the main body of the electron traps responsible for TL glow-peaks in the same temperature region 200-400 0 C. Despite their different origin all quartz samples show an appreciable homogeneity concerning the number and time position of the individual components, whereas, the relative TL/OSL intensities vary strongly from sample to sample with the integrated TL intensity being generally much less than the integrated OSL intensity.

  5. Application of pulsed OSL to the separation of the luminescence components from a mixed quartz/feldspar sample

    International Nuclear Information System (INIS)

    Denby, P.M.; Botter-Jensen, L.; Murray, A.S.; Thomsen, K.J.; Moska, P.

    2006-01-01

    It is known that the pulsed optically stimulated luminescence (OSL) characteristics of quartz and feldspars are very different. These differences can be used to preferentially discriminate against the feldspar signal in mixed quartz-bar feldspar mineral assemblages, or in separated quartz contaminated with a feldspar signal. We have developed instrumentation for the study of high-speed pulse stimulated OSL. Our system uses the standard blue/IR LED stimulation unit of a Riso reader (allowing stimulation pulses down to 1-2μs duration) and can thus be applied to the routine analysis of samples. Using this stimulation source, and high-speed photon timing, the OSL yield can be monitored throughout the pulsing cycle and subsequent OSL decay. It is found that the total photon yield per unit stimulation power in pulsed mode is, for quartz, twice and, for feldspar, nearly four times, that in continuous wave mode. Observation of this OSL signal, between stimulation pulses, is seen to be characteristic of the mineral being examined, and has been used to preferentially discriminate against feldspar contamination in a mixed quartz/feldspar sample. Simple implementation of this technique by gating the counting period, so that counts are only accumulated during a windowed period, reduces the feldspar signal to 1.6% of its original value relative to that of the quartz

  6. Detection of sub micro Gray dose levels using OSL phosphor LiMgPO_4:Tb,B

    International Nuclear Information System (INIS)

    Rawat, N.S.; Dhabekar, Bhushan; Muthe, K.P.; Koul, D.K.; Datta, D.

    2017-01-01

    Highlights: • LiMgPO4:Tb,B has been studied and shown to possesses minimum measurable dose (MMD) in sub micro Gray region. • MMD as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm"2 has been achieved. • The OSL measurements for low doses has strengthened and validated this claim. • OSL spectrum shows several emission peaks and the prominent peak around 380 nm. - Abstract: Detection of sub micro Gray doses finds application in personnel and environmental monitoring, and nuclear forensics. Recently developed LiMgPO_4:Tb,B (LMP) is highly sensitive Optically Stimulated Luminescence (OSL) phosphor with excellent dosimetric properties. The OSL emission spectrum of LMP consists of several peaks attributed to characteristic Tb"3"+ emission. The OSL emission peak at 380 nm is favorable for bi-alkali PMT used in RISO reader system. It is demonstrated that significant improvement in dose detection threshold can be realized for LMP by optimization of continuous wave (CW–) OSL parameters like stimulation intensity and readout time. The minimum measurable dose (MMD) as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm"2 has been achieved using this phosphor. The recommendations for choice of parameters for personnel and environmental monitoring are also discussed.

  7. Design of Interrogation Protocols for Radiation Dose Measurements Using Optically-Stimulated Luminescent Dosimeters.

    Science.gov (United States)

    Abraham, Sara A; Kearfott, Kimberlee J; Jawad, Ali H; Boria, Andrew J; Buth, Tobias J; Dawson, Alexander S; Eng, Sheldon C; Frank, Samuel J; Green, Crystal A; Jacobs, Mitchell L; Liu, Kevin; Miklos, Joseph A; Nguyen, Hien; Rafique, Muhammad; Rucinski, Blake D; Smith, Travis; Tan, Yanliang

    2017-03-01

    Optically-stimulated luminescent dosimeters are capable of being interrogated multiple times post-irradiation. Each interrogation removes a fraction of the signal stored within the optically-stimulated luminescent dosimeter. This signal loss must be corrected to avoid systematic errors in estimating the average signal of a series of optically-stimulated luminescent dosimeter interrogations and requires a minimum number of consecutive readings to determine an average signal that is within a desired accuracy of the true signal with a desired statistical confidence. This paper establishes a technical basis for determining the required number of readings for a particular application of these dosimeters when using certain OSL dosimetry systems.

  8. Thermally and optically stimulated luminescence correlated processes in X-ray irradiated KCl:Eu2+

    International Nuclear Information System (INIS)

    Chernov, V.; Melendrez Ao, R.; Piters, T.M.; Barboza-Flores, M.

    2001-01-01

    The effect of optical bleaching on thermoluminescence (TL) and thermal bleaching on optically stimulated luminescence (OSL) outputs in X-ray irradiated KCl : Eu 2+ have been investigated. The X-ray induced glow curves reveal three main peaks located at 370, 410 and 470 K. Illumination with 560 nm light leads to a drastic change of the TL glow curve. The 470 K peak is destroyed during bleaching. The other peaks initially increase in intensity and only after sufficiently long bleaching begin to decrease. After long-time bleaching, the TL peaks in X-ray irradiated crystals look like the TL peaks found in UV irradiated crystals. The effect of thermal bleaching on OSL is also very pronounced. The temperature dependencies show a step-by-step decrease of the OSL intensity correlated with the positions of the TL peaks. The result obtained shows that centers responsible for the TL peaks participate in OSL, but this participation seems not to be direct and is complicated by processes accompanying the F center bleaching

  9. Correlation of basic TL, OSL and IRSL properties of ten K-feldspar samples of various origins

    Energy Technology Data Exchange (ETDEWEB)

    Sfampa, I.K. [Aristotle University of Thessaloniki, Nuclear Physics Laboratory, 54124 Thessaloniki (Greece); Polymeris, G.S. [Institute of Nuclear Sciences, Ankara University, 06100 Besevler, Ankara (Turkey); Pagonis, V. [McDaniel College, Physics Department, Westminster, MD 21157 (United States); Theodosoglou, E. [Department of Mineralogy-Petrology-Economic Geology, School of Geology, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Tsirliganis, N.C. [Laboratory of Radiation Applications and Archaeological Dating, Department of Archaeometry and Physicochemical Measurements, ‘Athena’ R.& I.C., Kimmeria University Campus, GR67100 Xanthi (Greece); Kitis, G., E-mail: gkitis@auth.gr [Aristotle University of Thessaloniki, Nuclear Physics Laboratory, 54124 Thessaloniki (Greece)

    2015-09-15

    Highlights: • OSL and IRSL bleaching behavior of ten K-feldspar samples is presented. • OSL and IRSL decay curves were component resolved using tunneling model. • The growth of integrated OSL and IRSL signals versus time was described by new expression based on tunneling model. • Correlation between TL, OSL and IRSL signals and of all properties with K-feldspar structure was discussed. - Abstract: Feldspars stand among the most widely used minerals in dosimetric methods of dating using thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Having very good dosimetric properties, they can in principle contribute to the dating of every site of archaeological and geological interest. The present work studies basic properties of ten naturally occurring K-feldspar samples belonging to three feldspar species, namely sanidine, orthoclase and microcline. The basic properties studied are (a) the influence of blue light and infrared stimulation on the thermoluminescence glow-curves, (b) the growth of OSL, IRSL, residual TL and TL-loss as a function of OSL and IRSL bleaching time and (c) the correlation between the OSL and IRSL signals and the energy levels responsible for the TL glow-curve. All experimental data were fitted using analytical expressions derived from a recently developed tunneling recombination model. The results show that the analytical expressions provide excellent fits to all experimental results, thus verifying the tunneling recombination mechanism in these materials and providing valuable information about the concentrations of luminescence centers.

  10. BeOSL system for personal dosimetry : dosimetric characteristics and practical application

    International Nuclear Information System (INIS)

    Mende, E.

    2015-10-01

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  11. A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence

    International Nuclear Information System (INIS)

    Liu Yanping; Du Yanzhao; Chen Zhaoyang; Ba Weizhen; Fan Yanwei; Pan Shilie; Guo Qi

    2008-01-01

    The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)

  12. Systematic development of new thermoluminescence and optically stimulated luminescence materials

    Energy Technology Data Exchange (ETDEWEB)

    Yukihara, E.G., E-mail: eduardo.yukihara@okstate.edu [Physics Department, 145 Physical Sciences II, Oklahoma State University, Stillwater, OK 74078 (United States); Milliken, E.D.; Oliveira, L.C. [Physics Department, 145 Physical Sciences II, Oklahoma State University, Stillwater, OK 74078 (United States); Orante-Barron, V.R. [Departamento de Investigacion en Polimeros y Materiales, Universidad de Sonora, Hermosillo, Sonora 83000, Mexico (Mexico); Jacobsohn, L.G. [Center for Optical Materials Science and Engineering Technologies (COMSET), and School of Materials Science and Engineering, Clemson University, Clemson, SC (United States); Blair, M.W. [Materials Science and Technology Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2013-01-15

    This paper presents an overview of a systematic study to develop new thermoluminescence (TL) and optically stimulated luminescence (OSL) materials using solution combustion synthesis (SCS) for applications such as personal OSL dosimetry, 2D dose mapping, and temperature sensing. A discussion on the material requirements for these applications is included. We present X-ray diffraction (XRD) data on single phase materials obtained with SCS, as well as radioluminescence (RL), TL and OSL data of lanthanide-doped materials. The results demonstrate the possibility of producing TL and OSL materials with sensitivity similar to or approaching those of commercial TL and OSL materials used in dosimetry (e.g., LiF:Mg,Ti and Al{sub 2}O{sub 3}:C) using SCS. The results also show that the luminescence properties can be improved by Li co-doping and annealing. The presence of an atypical TL background and anomalous fading are discussed and deserve attention in future investigations. We hope that these preliminary results on the use of SCS for production of TL and OSL materials are helpful to guide future efforts towards the development of new luminescence materials for different applications. - Highlights: Black-Right-Pointing-Pointer TL and OSL material produced with sensitivity similar to commercial materials. Black-Right-Pointing-Pointer Luminescence properties improved by Li co-doping and annealing. Black-Right-Pointing-Pointer The presence of atypical TL background and anomalous fading observed.

  13. The potential of optically stimulated luminescence for medieval building; A case study at Termez, Uzbekistan

    International Nuclear Information System (INIS)

    Vieillevigne, Emmanuelle; Guibert, Pierre; Rita Zuccarello, Agnese; Bechtel, Francoise

    2006-01-01

    Luminescence techniques thermoluminescence (TL) and optically stimulated luminescence (OSL) are generally used to assess the chronology of the last firing of ceramics. In the field of building archaeology, fired bricks can be dated by these techniques. Nevertheless, these luminescence ages are not exactly related to the construction of the building itself, but to the production of the building materials. In some cases, re-use is possible and this raises problems with the interpretation of the dating results. This led us to employ optically stimulated luminescence in a less conventional way. Before bricks were sealed in masonry by mortar, they would have been exposed to day light, and, as a result, the optical traps of the crystals on the material surface should have been bleached (zeroed by light). Dating the end of the bleaching period is possible by OSL using blue light for stimulation and by IRSL (infrared stimulated luminescence) using IR stimulation. Thus the OSL or IRSL age for these crystals is directly related to the construction of the architectural structure. Experiments were carried out to determine the suitability of this approach and to solve practical problems of sampling. The results show that the bleaching light penetrates between 0.5 to 1 mm into the bricks, according to their transparency. This depth is sufficient to collect enough quartz and feldspar inclusions that have been affected by light in the past, and thus date the construction of the masonry directly. Attempts at surface dating of bricks collected at the medieval citadel of Termez, Uzbekistan, already dated by TL, were the starting point of this research

  14. Performance of OSL dosimeters in clinical beams from mammography; Desempenho de dosimetros OSL em feixes clinicos empregados na mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Caio V.; Cabete, Henrique V.; Alves, Fatima F.R.; Pires, Silvio R.; Medeiros, Regina B.; Freitas, Marcelo B. [Universidade Federal de Sao Paulo (HSP/EPM/UNIFESP), SP (Brazil). Escola Paulista de Medicina; Malthez, Anna Luiza M.C. [Universidade Estadual de Campinas (CPG/FEEC/UNICAMP), Campinas, SP (Brazil). Faculdade de Engenharia Eletrica e de Computacao. Programa de Pos-Graduacao

    2015-08-15

    The search for the relationship between dose and mammography image is critical to the quality of clinical practice. In this sense, dosimetry using optically stimulated luminescent detectors (OSLD) is configured as alternative to traditional methods and allows on-site dose checks received by patients. This study aimed to verify the performance of OSL dosimeters in clinical beams typically used in mammography. For this, aluminum oxide detectors, especially designed to reduce interference on the image quality, were exposed to radiation beam combining targets and filters of a mammography equipment with digital imaging system. In addition were also employed lithium fluoride detectors irradiated under the same conditions, together with a ionization chamber for determination of dose values. A homogeneous acrylic phantom was designed and used for simulating different breast and also determine internal dose values under the irradiation conditions. The results allowed the determination of calibration factors (OSL signal x dose) of the exposed detectors to the radiation beams typically used in clinical practice. The phantom images and the comparison between TL and OSL responses suggest the possibility of routine use of the OSL dosimetry system in mammography. (author)

  15. Comparison of the properties of various optically stimulated luminescence signals from potassium feldspar

    International Nuclear Information System (INIS)

    Fu Xiao; Zhang Jiafu; Zhou Liping

    2012-01-01

    Various optically stimulated luminescence signals from K-feldspar have been used to determine the equivalent doses of sediment samples. Understanding the properties of these optical signals is critical to evaluate their applicability and limitations to optical dating. In this paper, some properties of IRSL, post-IR OSL and post-IR IRSL signals (detected in the UV region using U-340 filters) from a museum sample of K-feldspar were investigated by analyzing the relationships between optical and TL signals, and the effect of optical bleaching and heating on optical signals. The trap parameters of the different optical signals were calculated using the pulse annealing method. The results show that this sample exhibits two regenerated TL peaks at ∼140 and ∼330 °C. Corresponding to the low temperature TL peak, the OSL and post-IR OSL signals appear to be more associated with lower temperature TL than the IRSL signal measured at 50 °C. Corresponding to the high temperature TL peak, the post-IR IRSL signals mainly originate from the more thermally stable traps associated with the high temperature TL, compared with the IRSL and post-IR OSL signals. However, the post-IR IRSL 225°C signal is shown to be hard to be bleached by blue light and simulated sunlight, compared with the IRSL 50°C and low temperature post-IR IRSL signals. The implication for optical dating is that the elevated temperature post-IR IRSL signals can be preferentially applied over other signals from K-feldspar, but it is desirable that the effectiveness of the pre-depositional zeroing of these signals is assessed.

  16. Dose-dependent optically stimulated luminescence of synthetic quartz at room temperature

    International Nuclear Information System (INIS)

    Kale, Y.D.; Gandhi, Y.H.; Gartia, R.K.

    2008-01-01

    Physical conditions such as annealing temperature, duration of annealing, ionizing radiation, etc., play a significant role in the applications of optically stimulated luminescence (OSL) dating as well as OSL dosimetry. Many efforts are made to understand the effect of these physical parameters on quartz specimens owing to its use in such applications. Such factors induce changes in OSL decay pattern. The definite correlation between color centers and luminescence sensitivity can be established on account of such pre-treatments to the specimen. The purpose of present investigations is to study the effect of ionizing radiation under identical physical conditions on OSL properties measured at room temperature. The shapes of decay curve and dose-response data are considered for this purpose. This study can reveal the changes in color centers in response to the pre-conditions to the specimen. It was found that the OSL decay remains slow and OSL properties change systematically with the rise in beta dose up to a critical dose; however, it changes the pattern when the beta exposure to the specimen was increased higher than the critical dose. This critical dose was found to be different for different temperature of annealing. The shape of decay curve up to the critical dose was also studied by considering the difference of OSL intensities between two successive durations from the observed OSL decay data. The results are explained based on the changes in available shallow traps during OSL measurement at room temperature with changes in pre-conditions to the specimens. The results also have been confirmed with the corresponding changes in ESR signals

  17. Protocols for Thermoluminescence and Optically Stimulated Luminescence Research at DOSAR

    International Nuclear Information System (INIS)

    Bernal, SM

    2004-01-01

    The Life Sciences Division (LSD) of Oak Ridge National Laboratory (ORNL) has a long record of radiation dosimetry research at the Dosimetry Applications Research (DOSAR) facility complex. These facilities have been used by a broad segment of the research community to perform a variety of experiments in areas including, but not limited to, radiobiology, radiation dosimeter and instrumentation development and calibration, and materials testing in a variety of radiation environments. Collaborations with the University of Tennessee-Knoxville (UTK) have also led to important contributions in the area of archaeometry, particularly as it relates to the use of radiation dosimetry to date archaeological artifacts. This manual is to serve as the primary instruction and operation manual for dosimetric and archaeometric research at DOSAR involving thermoluminescence (TL) and optically stimulated luminescence (OSL). Its purpose is to (1) provide protocols for common practices associated with the research, (2) outline the relevant organizational structure, (3) identify the Quality Assurance plan, and (4) describe all the procedures, operations, and responsibilities for safe and proper operation of associated equipment. Each person who performs research at DOSAR using TL/OSL equipment is required to read the latest revision of this manual and be familiar with its contents, and to sign and date the manual's master copy indicating that the manual has been read and understood. The TL/OSL Experimenter is also required to sign the manual after each revision to signify that the changes are understood. Each individual is responsible for completely understanding the proper operation of the TL/OSL equipment used and for following the guidance contained within this manual. The instructions, protocols, and operating procedures in this manual do not replace, supersede, or alter the hazard mitigation controls identified in the Research Safety Summary (''Thermoluminescence/Optically Stimulated

  18. BeO-OSL detectors for dose measurements in cell cultures

    International Nuclear Information System (INIS)

    Andreeff, M.; Freudenberg, R.; Kotzerke, J.; Sommer, D.; Reichelt, U.; Henniger, J.

    2009-01-01

    Aim: The absorbed dose is an important parameter in experiments involving irradiation of cells in vitro with unsealed radionuclides. Typically, this is estimated with a model calculation, although the results thus obtained cannot be verified. Generally used real-time measurement methods are not applicable in this setting. A new detector material with in vitro suitability is the subject of this work. Methods: Optically-stimulated luminescence (OSL) dosimeters based on beryllium oxide (BeO) were used for dose measurement in cell cultures exposed to unsealed radionuclides. Their qualitative properties (e. g. energy-dependent count rate sensitivity, fading, contamination by radioactive liquids) were determined and compared to the results of a Monte Carlo simulation (using AMOS software). OSL dosimeters were tested in common cell culture setups with a known geometry. Results: Dose reproducibility of the OSL dosimeters was ± 1.5%. Fading at room temperature was 0.07% per day. Dose loss (optically-stimulated deletion) under ambient lighting conditions was 0.5% per minute. The Monte Carlo simulation for the relative sensitivity at different beta energies provided corresponding results to those obtained with the OSL dosimeters. Dose profile measurements using a 6 well plate and 14 ml PP tube showed that the geometry of the cell culture vessel has a marked influence on dose distribution with 188 Re. Conclusion: A new dosimeter system was calibrated with β-emitters of different energy. It turned out as suitable for measuring dose in liquids. The dose profile measurements obtained are suitably precise to be used as a check against theoretical dose calculations. (orig.)

  19. Determination of U, Th and K for optically stimulated luminescence dating by NAA

    International Nuclear Information System (INIS)

    Qin Yali; Chen Zhe; Wu Weiming

    2010-01-01

    Optically stimulated luminescence dating techniques have been widely used in northern Loess ancient soil series and recorded climate environment change, ancient earthquake, the ancients site and archaeology research. The determination of U, Th and K using neutron activation analysis (NAA) has been optimized for the samples related to OSL dating research. The procedure for determination of U, Th, K in loess have been fixed by using Miniature neutron source reactor. This procedure of NAA will provide a reliable data base for optically stimulated luminescence dating research. (authors)

  20. Uncertainties associated with the use of optically stimulated luminescence in personal dosimetry

    International Nuclear Information System (INIS)

    Benevides, L.; Romanyukha, A.; Hull, F.; Duffy, M.; Voss, S.; Moscovitch, M.

    2011-01-01

    This study investigates several sources of uncertainty associated with the application of optically stimulated luminescence (OSL) to personal dosimetry. A commercial OSL system based on Al 2 O 3 :C was used for this study. First, it is demonstrated that the concept of repeated evaluation (readout) of the same dosemeter, often referred to as 're-analysis', can introduce uncertainty in the re-estimated dose. This uncertainty is associated with the fact that the re-analysis process depletes some of the populated traps, resulting in a continuous decrease of the OSL signal with each repeated reading. Furthermore, the rate of depletion may be dose-dependent. Second, it is shown that the previously reported light-induced fading in this system is the result of light leaks through miniature openings in the dosemeter badge. (authors)

  1. Properties of lithium aluminate for application as an OSL dosimeter

    International Nuclear Information System (INIS)

    Twardak, A.; Bilski, P.; Marczewska, B.; Lee, J.I.; Kim, J.L.; Gieszczyk, W.; Mrozik, A.; Sądel, M.; Wróbel, D.

    2014-01-01

    Several samples of undoped and carbon or copper doped lithium aluminate (LiAlO 2 ) were prepared in an attempt to achieve a material, which can be applicable in optically stimulated luminescence (OSL) dosimetry. All investigated samples are highly sensitive to ionizing radiation and show good reproducibility. The undoped and copper doped samples exhibit sensitivity several times higher than that of Al 2 O 3 :C, while sensitivity of the carbon doped samples is lower. The studied samples exhibit significant fading, but dynamics of signal loss is different for differently doped samples, what indicates a possibility of improving this characteristic by optimizing dopant composition. - Highlights: • OSL properties of lithium aluminate for personal dosimetry. • Doping influence on OSL fading of lithium aluminate. • Application of lithium aluminate in thermal neutron measurements

  2. TL-OSL study of Li{sub 3}PO{sub 4}: Mg, Cu phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Rahangdale, S. R., E-mail: sachin.rahangdale1@gmail.com; Wankhede, S. P. [Department of Physics, K.D.K.College of Engineering, Nagpur (India); Dhabekar, B. S. [RPAD, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Palikundwar, U. A.; Moharil, S. V. [Department of Physics, RTM Nagpur University, Nagpur, 440010 (India)

    2015-08-28

    In the present work, we report the thermoluminescence and optically stimulated luminescence properties of Mg and Cu doped Li{sub 3}PO{sub 4} phosphor. The phosphor was synthesized by precipitation method. The thermoluminescence dosimetric peak temperature for the phosphor varies with concentrations of Mg and Cu. Li{sub 3}PO{sub 4} shows good response to 470nm optical stimulation. The OSL sensitivity of the phosphor is approximately 12 times than that of standard Lithium magnesium phosphate. This study may help to develop this material for the application in real time dosimetry using optically stimulated luminescence.

  3. Dependence of the thermal influence on luminescence lifetimes from quartz on the duration of optical stimulation

    International Nuclear Information System (INIS)

    Chithambo, M.L.

    2003-01-01

    Time-resolved luminescence spectra may be measured from quartz at various stages of continuous optical stimulation in order to investigate properties of the spectra associated with the 'fast', 'medium', and 'slow' components of continuous optically stimulated luminescence (OSL). In this work, temperature related changes of luminescence lifetimes and luminescence intensity, both evaluated from time-resolved luminescence spectra recorded in the 'fast' 'medium' and 'slow' component regions of quartz OSL, have been investigated. The luminescence, stimulated at 525 nm, and measured at intervals between 20 deg. C and 200 deg. C reaches maximum intensity at 100 deg. C and decreases thereafter up to 200 deg. C, the maximum temperature of the investigations. Luminescence lifetimes, on the other hand, remain constant within 40±3 μs between 20 deg. C and 100 deg. C and then decrease down to about μs at 200 deg. C. The initial increase of luminescence intensity with temperature between 20 deg. C and 100 deg. C is discussed in terms of thermal assistance to luminescence stimulation. Beyond 100 deg. C, radiative recombination is affected by quenching of luminescence and reduction in luminescence lifetimes. The activation energy for thermal quenching was evaluated to be in the range 0.63±0.07 eV at all stimulation times and that of thermal assistance was evaluated to be about 0.06 eV for the 'fast' and 'medium' component regions and about 0.1 eV for the 'slow' component region of the OSL

  4. Sample dependent correlation between TL and LM-OSL in Al2O3:C

    International Nuclear Information System (INIS)

    Dallas, G.I.; Polymeris, G.S.; Stefanaki, E.C.; Afouxenidis, D.; Tsirliganis, N.C.; Kitis, G.

    2008-01-01

    Al 2 O 3 :C single crystals are known to exhibit different, sample dependent, glow-curve shapes. The relation between the Thermoluminescence (TL) traps and the linear modulated optically stimulation luminescence (LM-OSL) traps is of high importance. In the present work a correlation study is attempted using 23 single crystals with dimensions between 400 and 500μm. The correlation study involved two steps. In the first step, both TL glow curves and LM-OSL decay curves are deconvoluted and a one-to-one correlation between TL peaks and LM-OSL components is attempted. In the second step the TL glow-curves are corrected for thermal quenching, the corrected curves are deconvoluted and a new correlation between TL and LM-OSL individual components is performed

  5. Optically stimulated luminescence dosimetry with gypsum wallboard (drywall)

    International Nuclear Information System (INIS)

    Thompson, J. W.; Burdette, K. E.; Inrig, E. L.; Dewitt, R.; Mistry, R.; Rink, W. J.; Boreham, D. R.

    2010-01-01

    Gypsum wallboard (drywall) represents an attractive target for retrospective dosimetry by optically stimulated luminescence (OSL) in the event of a radiological accident or malicious use of nuclear material. In this study, wallboard is shown to display a radiation-induced luminescence signal (RIS) as well as a natural background signal (NS), which is comparable in intensity to the RIS. Excitation and emission spectra show that maximum luminescence intensity is obtained for stimulation with blue light-emitting diodes (470 nm) and for detection in the ultraviolet region (290-370 nm). It is necessary to decrease the optical stimulation power dramatically in order to adequately separate the RIS from the interfering background signal. The necessary protocols are developed for accurately measuring the absorbed dose as low as 500 mGy and demonstrate that the RIS decays logarithmically with storage time, with complete erasure expected within 1-4 d. (authors)

  6. Angular dependence of the nanoDot OSL dosimeter

    OpenAIRE

    Kerns, James R.; Kry, Stephen F.; Sahoo, Narayan; Followill, David S.; Ibbott, Geoffrey S.

    2011-01-01

    Purpose: Optically stimulated luminescent detectors (OSLDs) are quickly gaining popularity as passive dosimeters, with applications in medicine for linac output calibration verification, brachytherapy source verification, treatment plan quality assurance, and clinical dose measurements. With such wide applications, these dosimeters must be characterized for numerous factors affecting their response. The most abundant commercial OSLD is the InLight∕OSL system from Landauer, Inc. The purpose of...

  7. Pottery versus sediment: Optically stimulated luminescence dating of the Neolithic Vinča culture, Serbia

    DEFF Research Database (Denmark)

    Bate, Stephen; Stevens, Thomas; Buylaert, Jan-Pieter

    2017-01-01

    Optically stimulated luminescence (OSL) dating was applied to the Neolithic Vinča culture's type-site, Vinča Belo-Brdo, to establish best protocols for routine luminescence dating of similar Holocene sites, critical in understanding Neolithic to Chalcolithic cultural development. Equivalent dose ...

  8. Detection of sub micro Gray dose levels using OSL phosphor LiMgPO{sub 4}:Tb,B

    Energy Technology Data Exchange (ETDEWEB)

    Rawat, N.S., E-mail: naru@barc.gov.in [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India); Dhabekar, Bhushan [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India); Muthe, K.P. [Technical Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India); Koul, D.K.; Datta, D. [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India)

    2017-04-15

    Highlights: • LiMgPO4:Tb,B has been studied and shown to possesses minimum measurable dose (MMD) in sub micro Gray region. • MMD as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm{sup 2} has been achieved. • The OSL measurements for low doses has strengthened and validated this claim. • OSL spectrum shows several emission peaks and the prominent peak around 380 nm. - Abstract: Detection of sub micro Gray doses finds application in personnel and environmental monitoring, and nuclear forensics. Recently developed LiMgPO{sub 4}:Tb,B (LMP) is highly sensitive Optically Stimulated Luminescence (OSL) phosphor with excellent dosimetric properties. The OSL emission spectrum of LMP consists of several peaks attributed to characteristic Tb{sup 3+} emission. The OSL emission peak at 380 nm is favorable for bi-alkali PMT used in RISO reader system. It is demonstrated that significant improvement in dose detection threshold can be realized for LMP by optimization of continuous wave (CW–) OSL parameters like stimulation intensity and readout time. The minimum measurable dose (MMD) as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm{sup 2} has been achieved using this phosphor. The recommendations for choice of parameters for personnel and environmental monitoring are also discussed.

  9. Optically stimulated luminescence study on gamma-irradiated ice frozen from H sub 2 O and D sub 2 O

    CERN Document Server

    Yada, T; Hirai, M; Yamanaka, C; Ikeya, M

    2002-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence (TL) for gamma-irradiated ice samples have been investigated as future dating techniques for icy bodies in the solar system. The OSL around 400nm lasted more than 600s for gamma-irradiated H sub 2 O ice and D sub 2 O ice under 623-nm-light stimulation at 90 K; the latter was used to study the migration of hydrogen atoms. A defect containing trapped electrons is the most suitable explanation of the OSL emissions. The intensity of the TL peak at 120 K increased linearly with gamma-dosage increasing up to 15 kGy for both D sub 2 O ice and H sub 2 O ice. Intensities of both OSL and TL for D sub 2 O ice were larger than those for H sub 2 O ice. The TL peak related to H sub 2 O was observed but its thermal characteristics did not agree with those of OH and HO sub 2 radicals measured by ESR. The OSL method should be employed in future surveys in the solar system.

  10. Thermally and optically stimulated radiative processes in Eu and Y co-doped LiCaAlF6 crystal

    International Nuclear Information System (INIS)

    Fukuda, Kentaro; Yanagida, Takayuki; Fujimoto, Yutaka

    2015-01-01

    Yttrium co-doping was attempted to enhance dosimeter performance of Eu doped LiCaAlF 6 crystal. Eu doped and Eu, Y co-doped LiCaAlF 6 were prepared by the micro-pulling-down technique, and their dosimeter characteristics such as optically stimulated luminescence (OSL) and thermally stimulated luminescence (TSL) were investigated. By yttrium co-doping, emission intensities of OSL and TSL were enhanced by some orders of magnitude. In contrast, scintillation characteristics of yttrium co-doped crystal such as intensity of prompt luminescence induced by X-ray and light yield under neutron irradiation were degraded

  11. INTEGRATED CIRCUITS FROM MOBILE PHONES AS POSSIBLE EMERGENCY OSL/TL DOSIMETERS.

    Science.gov (United States)

    Sholom, S; McKeever, S W S

    2016-09-01

    In this article, optically stimulated luminescence (OSL) data are presented from integrated circuits (ICs) extracted from mobile phones. The purpose is to evaluate the potential of using OSL from components in personal electronic devices such as smart phones as a means of emergency dosimetry in the event of a large-scale radiological incident. ICs were extracted from five different makes and models of mobile phone. Sample preparation procedures are described, and OSL from the IC samples following irradiation using a (90)Sr/(90)Y source is presented. Repeatability, sensitivity, dose responses, minimum measureable doses, stability and fading data were examined and are described. A protocol for measuring absorbed dose is presented, and it was concluded that OSL from these components is a viable method for assessing dose in the days following a radiological incident. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Optically stimulated luminescence dating of rock surfaces

    DEFF Research Database (Denmark)

    Sohbati, Reza

    There are many examples of rock surfaces, rock art and stone structures whose ages are of great importance to the understanding of various phenomena in geology, climatology and archaeology. Optically stimulated luminescence (OSL) dating is a well-established chronological tool that has successfully...... to include the effects of the environmental dose rate. By fitting the model to the dose-depth variation from a single clast, four events (two light exposures of different durations each followed by a burial period) in the history of a single cobble are identified and quantified. However, the use of model...

  13. The preliminary application of OSL in comparison with TL for authentication of ancient Chinese bricks

    International Nuclear Information System (INIS)

    Leung, P.L.; Tang Qiang; Li, Mike; Zhang Chunxiang

    2005-01-01

    The single-aliquot regenerative-dose (SAR) protocol with optically stimulated luminenscence (OSL) was applied to measure the equivalent dose (ED) of ancient Chinese bricks ranging in age from 180 to 1600 years. In the protocol, sensitivity changes can be corrected by using OSL response to a fixed test dose during measurement. For comparative study between OSL and TL, thermoluminescence (TL) measurement procedures were also applied to determine the paleodose of the bricks. Both results of OSL and TL are in agreement with the known ages of the bricks, and the paleodose ratios(ED OSL / ED TL ) are between 0.96 and 1.21, mean value 1.08+/-0.02. The annual doses of the bricks, estimated by the paleodoses and the known ages, range from 5.07 to 6.79mGy/a, comparable with the measured annual dose values of the bricks. Therefore, it is concluded that the SAR protocol is a rapid and effective OSL technique to authenticate Chinese bricks

  14. A comparative study between OSL and TL techniques for the dating of ancient chinese bricks

    International Nuclear Information System (INIS)

    Leung, P.L.; Li, M.; Tang Qiang; Zhang Chunxiang

    2004-01-01

    The single-aliquot regenerative-dose (SAR) protocol to the optically stimulated luminescence (OSL) was applied to measure the paleodose of ancient Chinese bricks with an age range from 180 to 1600 years. In the protocol, sensitivity changes can be corrected by using OSL response to a fixed test dose during measurement. For comparative study between OSL and TL, thermoluminescence (TL) measurement procedures were also applied to determine the paleodose of the bricks. Both results of OSL and TL are in good agreement with, and the paleodose ratios (De OSL /De TL ) are between 0.96 and 1.21, with a mean value of 1.08 ± 0.07. The annual dose of the bricks, estimated by the paleodoses and the known ages, ranges from 5.07 to 6.85 mGy/a, comparable with the measured annual dose values. Therefore, it is concluded that the SAR protocol is a rapid and effective OSL technique to authenticate Chinese bricks. (authors)

  15. TL and OSL properties of Mn2+-doped MgGa2O4 phosphor

    Science.gov (United States)

    Luchechko, A.; Zhydachevskyy, Ya; Maraba, D.; Bulur, E.; Ubizskii, S.; Kravets, O.

    2018-04-01

    The oxide MgGa2O4 spinel ceramics doped with Mn2+ ions was synthesized by a solid-state reaction at 1200 °C in air. The activator concentration was equal 0.05 mol% of MnO. Phase purity of the synthesized samples was analyzed by X-ray diffraction technique. This spinel ceramics show efficient green emission in the range from 470 to 550 nm with a maximum at about 505 nm under UV or X-ray excitations, which is due to Mn2+ ions. MgGa2O4: Mn2+ exhibits intense thermoluminescence (TL) and optically stimulated luminescence (OSL) after influence of ionizing radiation. Are complex nature of the TL glow curves is associated with a significant number of structural defects that are responsible for the formation of shallow and deep electron traps. In this work, time-resolved OSL characteristics of the samples exposed to beta particles are reported for the first time. A light from green LED was used for optical stimulation. Obtained TL and OSL results suggest MgGa2O4:Mn2+ as perspective material for further research and possible application in radiation dosimetry.

  16. Thermally and optically stimulated radiative processes in Eu and Y co-doped LiCaAlF{sub 6} crystal

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Kentaro, E-mail: ken-fukuda@tokuyama.co.jp [Tokuyama Corporation, 1-1 Mikage-cho, Shunan-shi, Yamaguchi 745-8648 (Japan); Yanagida, Takayuki; Fujimoto, Yutaka [Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu, Kitakyushu, Fukuoka 808-0196 (Japan)

    2015-06-01

    Yttrium co-doping was attempted to enhance dosimeter performance of Eu doped LiCaAlF{sub 6} crystal. Eu doped and Eu, Y co-doped LiCaAlF{sub 6} were prepared by the micro-pulling-down technique, and their dosimeter characteristics such as optically stimulated luminescence (OSL) and thermally stimulated luminescence (TSL) were investigated. By yttrium co-doping, emission intensities of OSL and TSL were enhanced by some orders of magnitude. In contrast, scintillation characteristics of yttrium co-doped crystal such as intensity of prompt luminescence induced by X-ray and light yield under neutron irradiation were degraded.

  17. The interpretation of quartz optically stimulated luminescence equivalent dose versus time plots

    International Nuclear Information System (INIS)

    Bailey, R.M.

    2000-01-01

    Numerical modelling has shown that the form of the quartz OSL shine plateau (hereafter 'D e (t)-plot') is influenced by the effects of phototransferred TL in the ∼110 deg. C region. It is suggested also that the presence of multiple OSL components (as described by Partial bleaching and the decay form characteristics of quartz OSL. Radiat. Meas., 27, 123-136. The form of the optically stimulated luminescence signal of quartz: implications of dating. Unpublished PhD thesis, University of London) affects the form of the D e (t)-plot. Laboratory measurements of a fully reset and artificially dosed sample yielded non-flat D e (t)-plots, the deviation being greater for the larger of the two simulated palaeodoses, in accordance with theoretical predictions. It is suggested that the so-called 'shine plateau' test is of limited use in assessing the bleaching history of quartz sediments

  18. Implementation of a OSL dosimetry laboratory at IRD/CNEN-BR

    International Nuclear Information System (INIS)

    Moura, Jose; Alencar, Marcus A. Vallim de; Mauricio, Claudia L.P.; Hunt, John

    2005-01-01

    The optically stimulated luminescence (OSL) it is a phenomenon characterized by the luminous emission of an insulating material or semiconductor, during your exhibition to the light, after it being previously exposed to the ionizing radiation. This phenomenon has been used more and more in the dosimetry of the ionizing radiations, why the intensity OSL of some materials is proportional to the absorbed dose in these. The processes OSL and thermoluminescence (TL) they only differ in the stimulation form for light emission. One of the advantages of the OSL process in relation to the traditional technique of TL dosimetry is the no complete destruction of the information of the absorbed dose in the material during the reading. Following this world tendency, the External Individual Monitoring Service of the Institute of Radioprotection and Dosimetry (SEMEX/IRD) implemented the OSL dosimetry laboratory. The acquired reader was the reader model LAUGHTER TL/OSL-GIVE-15B/C. With that reader it is possible to do readings TL and OSL. After the installation of the equipment in a darkroom with temperature and humidity controlled, they were made the preliminary tests with the equipment and the laboratory became operational. After this first stage, they were initiate the studies with the Al 2 O 3 :C dosimeters by Harshaw under the denomination TLD 500. The reading parameters and thermal treatment were optimized to study the applicability of OSL technique with the TLD 500 dosimeter for the use in environmental monitoring. It was also verified the linearity of the system for high doses (10 mGy-1 Gy) seeking your use in radiotherapy, as well as the effect of the thermal treatment in the OSL signal of the Al 2 O 3 :C dosimeter. The results prove the possibility of use of this system in environmental monitoring. The reproductivity of the system for the air kerma value of 100 mGy, considering a degree of confidence of 95%, was to 4,8% for OSL readings and 5,6% for TL. In the two cases

  19. Optimization of CW-OSL parameters for improved dose detection threshold in Al2O3:C

    International Nuclear Information System (INIS)

    Rawat, N.S.; Dhabekar, B.; Kulkarni, M.S.; Muthe, K.P.; Mishra, D.R.; Soni, A.; Gupta, S.K.; Babu, D.A.R.

    2014-01-01

    Continuous wave optically stimulated luminescence (CW-OSL) is relatively a simple technique that offers good signal to noise ratio (SNR) and involves simple instrumentation. This study reports the influence and optimization of CW-OSL parameters on minimum detectable dose (MDD) using α-Al 2 O 3 :C phosphor. It is found that at a given stimulation intensity MDD in CW-OSL mode depends on signal integration time. At lower integration times MDD is inferior. It exhibits an improvement for intermediate values, shows a plateau region and deteriorates as integration time increases further. MDD is found to be ∼127 μGy at 4 mW/cm 2 stimulation intensity for integration time of 0.1 s, which improves to ∼10.5 μGy for 60 s. At stimulation intensity of 72 mW/cm 2 , MDD is 37 μGy for integration time of 60 s and improves significantly to 7 μGy for 1 s. - Highlights: • CW-OSL parameters are optimized to obtain best SNR and MDD in Al 2 O 3 :C. • MDD is found to depend on signal integration time and stimulation intensity. • With time, MDD initially improves, stabilizes then deteriorates. • At a given intensity, MDD is optimum for a certain range of integration time

  20. Spatially-resolved measurement of optically stimulated luminescence and time-resolved luminescence

    International Nuclear Information System (INIS)

    Bailiff, I.K.; Mikhailik, V.B.

    2003-01-01

    Spatially-resolved measurements of optically stimulated luminescence (OSL) were performed using a two-dimensional scanning system designed for use with planar samples. The scanning system employs a focused laser beam to stimulate a selected area of the sample, which is moved under the beam by a motorised stage. Exposure of the sample is controlled by an electronic shutter. Mapping of the distribution of OSL using a continuous wave laser source was obtained with sub-millimeter resolution for samples of sliced brick, synthetic single crystal quartz, concrete and dental ceramic. These revealed sporadic emission in the case of brick or concrete and significant spatial variation of emission for quartz and dental ceramic slices. Determinations of absorbed dose were performed for quartz grains within a slice of modern brick. Reconfiguration of the scanner with a pulsed laser source enabled quartz and feldspathic minerals within a ceramic sample to be thinner region. about 6 nm from the extrapolation of themeasuring the time-resolved luminescence spectrum

  1. Optically stimulated luminescence of common plastic materials for accident dose reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Chang, I.; Lee, J. I.; Kim, J. L. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Chung, K. S. [Gyeongsang National Univ., Jinju (Korea, Republic of)

    2014-05-15

    Optically stimulate luminescence(OSL) has many applications in a variety of radiation dosimetry fields, including personal dosimetry, environmental radiation level monitor, retrospective dosimetry for dating, and reconstruction of radiation doses from radiation accident. In the reconstruction of radiation doses from radiation accident, OSL technique has been used to estimate the doses exposed to public area through analysis of housewares or house construing materials. Recently, many efforts have been carried out for dose reconstruction using personal electronic devices such as mobile phones and USB memory chips. Some of natural minerals such as quartz and feldspar have OSL properties. Quartz is the second most abundant mineral in continental crust of the Earth. In some of common plastics, inorganic fillers (quartz, alumina etc.) are added to make strengthen of their properties depends on applications areas. The aim of this research is to explore a possibility of use of the common plastic materials for dose reconstruction in radiation accident case. In this research the OSL dose response-curve and fading characteristics of the common plastics were tested and evaluated. Finally, we expect this work contribute to elevate the possibility of the dose reconstruction. The general conclusion of this work is that the possibility of dose reconstruction using common plastic materials is showed using the OSL characteristics of the materials. However, the tested common plastic materials have relatively low sensitivities. Further work is required to establish a database of OSL properties of common plastic materials for emergency dose reconstruction by using housewares.

  2. Influence of pre-measurement thermal treatment on OSL of synthetic quartz measured at room temperature

    International Nuclear Information System (INIS)

    Kale, Y.D.; Gandhi, Y.H.

    2008-01-01

    Much effort has been made to study the influence of pre-measurement thermal treatment and ionizing radiation on quartz specimens owing to its use in a large number of applications. Optically stimulated luminescence (OSL) being a structured and sensitive phenomenon promises to correlate the responsible color center and luminescence emission. OSL studies on quartz with such conditions can reveal many significant results. The aim of the present investigation is to understand the effect of annealing temperature on OSL characteristics of synthetic quartz recorded at room temperature. At identical annealing duration and β-dose, the shape of OSL decay curve remains non-exponential; when specimens annealed at lower temperature (∼400 deg. C). The shape of decay curve changes to exponential in nature along with rise in OSL intensity when the specimen was given higher temperature of annealing (>400 deg. C). The effects of such protocol on pattern of OSL sensitivity as well as area under the OSL decay curve are also presented here. The presence of shallow traps, when OSL decay curve was recorded at room temperature seems to be responsible for the changes in OSL pattern. The influence of shallow traps is attributed to non-exponential decay of OSL recorded at room temperature

  3. Optimising the separation of quartz and feldspar optically stimulated luminescence using pulsed excitation

    International Nuclear Information System (INIS)

    Ankjaergaard, C.; Jain, M.; Thomsen, K.J.; Murray, A.S.

    2010-01-01

    In luminescence dating, the two most commonly used natural minerals, quartz and feldspar, are exposed to different dose rates in the natural environment, and so record different doses. The luminescence signals also have different stabilities. For accurate dosimetry, the signals from these two minerals must be separated, either by physical separation of the mineral grains, or by instrumental separation of the luminescence signals. The luminescence signals from quartz and feldspar have different luminescence lifetimes under pulsed optical stimulation. This difference in lifetime can be used to discriminate between the two signals from a mixed quartz-feldspar sample. The purpose of this study is to identify optimum measurement conditions for the best separation of quartz OSL from that of feldspar in a mixed sample using pulsed stimulation and time-resolved OSL. We integrate the signal from 5 μs after the LEDs are switched off until just before the LEDs are switched on again, with the pulse on-time equal to the pulse off-time of 50 μs. By using only the initial interval of the pulsed OSL decay curve (equivalent to 0.2 s of CW-OSL using blue light at 50 mW cm -2 ) we find that the quartz to feldspar pulsed OSL intensity ratio is at a maximum. By using these parameters with an additional infrared (IR) stimulation at 175 o C before measurement (to further reduce the feldspar signal intensity), we obtain a factor of 25 enhancement in signal separation compared to that from a conventional prior-IR CW measurement. This ratio can be further improved if the counting window in the pulse off-time is restricted to detect between 20 and 50 μs instead of the entire off-period.

  4. Using OSL dating to quantify rates of Earth surface processes

    Science.gov (United States)

    Rhodes, E. J.; Rittenour, T. M.

    2010-12-01

    In Optically Stimulated Luminescence (OSL), the dating signal is reset when mineral grains are exposed to light or heat, and gradually rebuilds during subsequent burial by interaction with ionising radiation. Quartz and feldspar provide useful OSL signals demonstrating rapid signal reduction in only seconds of light exposure. Age estimates ranging from under 1 year to around 200,000 years can be determined for a wide range of sedimentary contexts, including dunes, marine deposits, fluvial and glacial environments, and recent developments provide the framework for low temperature thermochronometric applications on timescales comparable with rapid climate fluctuations. In this presentation, we explore the range of applications for determining rates of Earth surface processes using OSL. We examine technical limitations, and provide a framework for overcoming current difficulties experienced in several specific regions and contexts. We will focus on OSL dating applications to glacigenic and fluvial records, along with use of the technique in tectonic and paleoseismic contexts. In many ways, these represent the most challenging environments for OSL; rapid high energy deposition is associated with incomplete signal zeroing, and the characteristics of quartz in many of these environments make it difficult to derive precise age estimates using this mineral. We will introduce innovative methods to overcome these limitations, both existing and those under development.

  5. A comparison of single and multiple aliquot TT-OSL data sets for sand-sized quartz from the Arabian Peninsula

    International Nuclear Information System (INIS)

    Rosenberg, T.M.; Preusser, F.; Wintle, A.G.

    2011-01-01

    The quartz OSL signal from dune sands from Saudi Arabia and Oman start to saturate at doses of about 100 Gy. In order to try to date dune sands with greater expected doses, a previously published, single-aliquot, regenerative-dose protocol (SAR) for thermally-transferred optically stimulated luminescence (TT-OSL) was tested. Dose recovery tests, recycling and recuperation ratios showed robust functioning and dose response curves demonstrated the potential to extend the dose range to beyond 600 Gy. Multiple aliquot additive dose (MAAD) TT-OSL protocols were used to test for sensitivity changes in the SAR TT-OSL protocol up to doses of 1200 Gy. A strong dose dependent deviation of the SAR TT-OSL relative to the MAAD TT-OSL dose response is observed. Comparison of the TT-OSL and OSL sensitivity data obtained from the MAAD and SAR data sets shows a lack of proportionality between TT-OSL and OSL for the SAR data which will result in a problem when SAR dose response curves are constructed using many regeneration points with doses above 300 Gy.

  6. Firing temperature of pottery using TL and OSL techniques

    International Nuclear Information System (INIS)

    Polymeris, G.S.; Sakalis, A.; Papadopoulou, D.; Dallas, G.; Kitis, G.; Tsirliganis, N.C.

    2007-01-01

    Several methods of thermal analysis are used to determine in the laboratory the firing temperature of ancient ceramic sherds. These methods are based primarily on changes of physical characteristics occurring when clay minerals are heated. The luminescence properties of quartz grains in a ceramic matrix also undergo certain changes during firing. The possibility of measuring the sensitivity change (sensitization) of quartz in order to determine the firing temperature of archeological ceramic artifacts was investigated. The sensitivity change was studied for both the thermoluminescence (TL) and the optically stimulated luminescence (OSL) signal for a ceramic sample of known firing temperature. Various segments of the sample were annealed to a different temperature. Subsequently, the initial sensitivity, as well as the thermal and the pre-dose sensitization were measured for both TL and OSL at room temperature as a function of the annealing temperature. The obtained TL glow curves showed different shapes for annealing temperatures above the firing temperature. Thermal and pre-dose sensitizations also exhibited a similar, although less prominent, rise. The OSL signal was analyzed by integrating the raw signal over the initial second of stimulation. The initial sensitivity showed an abrupt change for annealing temperatures around the firing temperature. An alternative approach used for the analysis of the OSL signal involved a full-component resolved sensitization study. The same abrupt change for the initial sensitivity of both the first and second components was observed, as well as, a clear but not very prominent thermal sensitization trend for annealing temperatures above the firing temperature

  7. Thermally and optically stimulated luminescence of early medieval blue-green glass mosaics

    Energy Technology Data Exchange (ETDEWEB)

    Galli, A. E-mail: anna.galli@mater.unimib.it; Martini, M.; Montanari, C.; Sibilia, E

    2004-12-01

    The preliminary results of a study related to luminescent mechanisms in glass mosaic tesserae are presented. The samples came from a medieval glass deposit found during archaeological excavations in the S. Lorenzo Church in Milan. Energy Dispersive X-rays Fluorescence (EDXRF) measurements were performed to obtain information on the elemental composition of the materials. Thermally Stimulated Luminescence (TSL, both conventional and wavelength resolved) and Optically Stimulated Luminescence (OSL) analyses allowed to get information about traps and luminescence centres. The observed luminescence characteristics were close to that of quartz, showing the presence of an easy to bleach trap (300 deg. C, 1.95 eV) and of a hard to bleach trap (350 deg. C, 2.20 eV); charge transfer phenomena, involving the low-temperature peaks have been observed. There is a strong indication that the easy to bleach traps are responsible for both OSL and TSL emission at 300 deg. C.

  8. Thermally and optically stimulated luminescence of early medieval blue-green glass mosaics

    International Nuclear Information System (INIS)

    Galli, A.; Martini, M.; Montanari, C.; Sibilia, E.

    2004-01-01

    The preliminary results of a study related to luminescent mechanisms in glass mosaic tesserae are presented. The samples came from a medieval glass deposit found during archaeological excavations in the S. Lorenzo Church in Milan. Energy Dispersive X-rays Fluorescence (EDXRF) measurements were performed to obtain information on the elemental composition of the materials. Thermally Stimulated Luminescence (TSL, both conventional and wavelength resolved) and Optically Stimulated Luminescence (OSL) analyses allowed to get information about traps and luminescence centres. The observed luminescence characteristics were close to that of quartz, showing the presence of an easy to bleach trap (300 deg. C, 1.95 eV) and of a hard to bleach trap (350 deg. C, 2.20 eV); charge transfer phenomena, involving the low-temperature peaks have been observed. There is a strong indication that the easy to bleach traps are responsible for both OSL and TSL emission at 300 deg. C

  9. SU-E-T-592: OSL Response of Al2O3:C Detectors Exposed to Therapeutic Proton Beams

    Energy Technology Data Exchange (ETDEWEB)

    Granville, DA [Carleton Laboratory for Radiotherapy Physics, Carleton University, Ottawa, ON (Canada); Flint, DB; Sawakuchi, GO [The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To characterize the response of Al{sub 2}O{sub 3}:C optically stimulated luminescence (OSL) detectors (OSLDs) exposed to therapeutic proton beams of differing beam quality. Methods: We prepared Al{sub 2}O{sub 3}:C OSLDs from the same material as commercially available nanoDot dosimeters (Landauer, Inc). We irradiated the OSLDs in modulated proton beams of varying quality, as defined by the residual range. An absorbed dose to water of 0.2 Gy was delivered to all OSLDs with the residual range values varying from 0.5 to 23.5 cm (average LET in water from ∼0.5 to 2.5 keV/µm). To investigate the beam quality dependence of different emission bands within the OSL spectrum, we performed OSLD readouts using both continuous-wave stimulation (CW-OSL) and pulsed stimulation (P-OSL) with two sets of optical filters (Hoya U-340 and Kopp 5113). For all readout modes, the relative absorbed dose sensitivity (S{sub rel}) for each beam quality was calculated using OSLDs irradiated in a 6 MV photon beam as a reference. Results: We found that the relative absorbed dose sensitivity was highly dependent on both readout mode and integration time of the OSL signal. For CW-OSL signals containing only the blue emission band, S{sub rel} was between 0.85 and 0.94 for 1 s readouts and between 0.82 and 0.93 for 10 s readouts. Similarly, for P-OSL readouts containing only the blue emission band S{sub rel} ranged from 0.86 to 0.91, and 0.82 to 0.93 for 1 s and 10 s readouts, respectively. For OSLD signals containing only the UV emission band, S{sub rel} ranged from 1.00 to 1.46, and 0.97 to 1.30 for P-OSL readouts of 1 s and 10 s, respectively. Conclusion: For measurements of absorbed dose using Al{sub 2}O{sub 3}:C OSLDs in therapeutic proton beams, dependence on beam quality was smallest for readout protocols that selected the blue emission band with small integration times. DA Granville received financial support from the Natural Sciences and Engineering

  10. Optically stimulated luminescence (OSL) dating of shallow marine sediments to develop an analysis method of late Quaternary geodynamics

    International Nuclear Information System (INIS)

    Hataya, Ryuta; Shirai, Masaaki

    2003-01-01

    To develop an analysis method of geodynamics, we have examined the applicability of the OSL dating of marine terrace deposits. We have done the OSL dating, using the multiple-aliquot additive-dose technique, of shallow marine sediments from the upper part the Kioroshi Formation in Ibaraki Prefecture, which are correlated to Marine Oxygen Isotope Stage (MIS) 5e-5c. Marine terrace deposit consists mainly of shallow marine sediment. OSL ages of foreshore and foreshore-shoreface beds are 88-112 Ka, and are in good agreement with the geological/geomorphological data. On the other hand, OSL ages of the backshore bed are younger, and ones of the shoreface bed are older than geologically estimated ages. These results show that OPSL dating method can date shallow marine sediment using samples from foreshore and foreshore-shoreface beds, and that this method can distinguish terrace deposits formed in MIS5 and that in MIS7 by taking geomorphologic information into account. These results contribute to the characterization of long-term geological movement in coastal areas. (author)

  11. Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence technique

    International Nuclear Information System (INIS)

    Pinto, Teresa Cristina Nathan Outeiro

    2010-01-01

    A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al 2 O 3 :C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al 2 O 3 :C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al-2O 3 :C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation. (author)

  12. Thermal activation of OSL as a geothermometer for quartz grain heating during fault movements

    CERN Document Server

    Rink, W J; Rees-Jones, J; Schwarcz, H P

    1999-01-01

    In discussions of ESR dating of fault movements, there has been much debate whether zeroing of ESR signals is a mechanical shearing effect or caused by frictional heating. The OSL (optically stimulated luminescence) sensitivity of quartz is known to increase after heating. This thermal activation of dose response of the OSL in quartz should be useful as a geothermometer to test whether quartz particles in fault gouge had been heated. We tested the OSL sensitivities of quartz from fault gouge, and from a control (quartz grains from sandstone) and were able to show heat-induced enhancement of OSL sensitivity to a test dose. We observed that relative enhancement of OSL dose response (ratio of heated to unheated single aliquots) is significantly less for the finest grains (45-75 and 100-150 mu m) compared with coarser grains (150-250 mu m). These data are consistent with a model of zeroing of the quartz grains during faulting, by frictional heating localized to the grain boundaries, which would be expected to aff...

  13. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    International Nuclear Information System (INIS)

    Hubner, S.

    2014-08-01

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  14. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hubner, S., E-mail: stephan.huebner@helmholtz-muenchen.de [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, D-80219, Munich (Georgia)

    2014-08-15

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  15. Thermally and optically stimulated luminescence of new ZnO nano phosphors exposed to beta radiation

    International Nuclear Information System (INIS)

    Cruz V, C.; Burruel I, S.E.; Grijalva M, H.; Chernov, V.; Bernal, R.

    2006-01-01

    In this work, we report the thermoluminescence (TL) and the optically stimulated luminescence (OSL) of ZnO nano phosphors obtained by thermal annealing of ZnS powders synthesized by precipitation in a chemical bath deposition reaction. To obtain nanocrystalline ZnO, ZnS pellet-shaped samples were subjected to a sintering process at 700 C during 24 under air atmosphere. Some samples were exposed to beta particles in the 0.15-10.15 kGy dose range and the integrated thermoluminescence as a function of dose increased as dose increased, with no saturation clue for the tested doses. Computerized glow-curve deconvolution of the experimental TL curves in individual peaks revealed a second order kinetics. In order to test the BOSL (Blue Optically Stimulated Luminescence) response, samples were beta irradiated with doses up to 600 Gy, showing an increasing OSL intensity as dose increases. From the experimental results that we have obtained, we conclude that the new ZnO phosphors under investigation are good candidates to be used as dosimetric materials. (Author)

  16. Emergency EPR and OSL dosimetry with table vitamins and minerals.

    Science.gov (United States)

    Sholom, S; McKeever, S W S

    2016-12-01

    Several table vitamins, minerals and L-lysine amino acid have been preliminarily tested as potential emergency dosemeters using electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) techniques. Radiation-induced EPR signals were detected in samples of vitamin B2 and L-lysine while samples of multivitamins of different brands as well as mineral Mg demonstrated prominent OSL signals after exposure to ionizing radiation doses. Basic dosimetric properties of the radiation-sensitive substances were studied, namely dose response, fading of the EPR or OSL signals and values of minimum measurable doses (MMDs). For EPR-sensitive samples, the EPR signal is converted into units of dose using a linear dose response and correcting for fading using the measured fading dependence. For OSL-sensitive materials, a multi-aliquot, enhanced-temperature protocol was developed to avoid the problem of sample sensitization and to minimize the influence of signal fading. The sample dose in this case is also evaluated using the dose response and fading curves. MMDs of the EPR-sensitive samples were below 2 Gy while those of the OSL-sensitive materials were below 500 mGy as long as the samples are analyzed within 1 week after exposure. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Dose response of hydrazine - Deproteinated tooth enamel under blue light stimulation

    International Nuclear Information System (INIS)

    Yuece, Ulkue Rabia; Meric, Niyazi; Atakol, Orhan; Yasar, Fusun

    2010-01-01

    The beta dose response and Optically Stimulated Luminescence (OSL) signal stability characteristics of human tooth enamel deproteinated by hydrazine reagent under blue photon stimulation are reported. Removal of the protein organic component of tooth enamel resulted in a higher OSL sensitivity and slower fading of OSL signals. The effect of chemical sample preparation on the enamel sample sensitivity is discussed and further steps to make this deproteinization treatment suitable for in vitro dose reconstruction studies are suggested.

  18. Dose response of hydrazine - Deproteinated tooth enamel under blue light stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Yuece, Ulkue Rabia, E-mail: ulkuyuce@hotmail.co [Ankara University, Faculty of Engineering, Department of Engineering Physics, 06100, Tandogan - Ankara (Turkey); Meric, Niyazi, E-mail: meric@ankara.edu.t [Ankara University, Faculty of Engineering, Department of Engineering Physics, 06100, Tandogan - Ankara (Turkey); Atakol, Orhan, E-mail: atakol@science.ankara.edu.t [Ankara University, Science Faculty, Department of Chemistry, 06100, Tandogan - Ankara (Turkey); Yasar, Fusun, E-mail: ab121310@adalet.gov.t [Council of Forensic Medicine, Ankara Branch, Ankara (Turkey)

    2010-08-15

    The beta dose response and Optically Stimulated Luminescence (OSL) signal stability characteristics of human tooth enamel deproteinated by hydrazine reagent under blue photon stimulation are reported. Removal of the protein organic component of tooth enamel resulted in a higher OSL sensitivity and slower fading of OSL signals. The effect of chemical sample preparation on the enamel sample sensitivity is discussed and further steps to make this deproteinization treatment suitable for in vitro dose reconstruction studies are suggested.

  19. Relative response of TL and component-resolved OSL to alpha and beta radiations in annealed sedimentary quartz

    International Nuclear Information System (INIS)

    Polymeris, George S.; Afouxenidis, Dimitrios; Raptis, Spyridoula; Liritzis, Ioannis; Tsirliganis, Nestor C.; Kitis, George

    2011-01-01

    Knowledge of the relative luminescence response to alpha and beta radiation is very important in TL and OSL dating. In the present study the relative alpha to beta response is studied in a sedimentary quartz sample, previously fired at 900 deg. C for 1 h, in the dose region between 1 and 128 Gy, for both thermoluminescence (TL) and linearly modulated optically stimulated luminescence (LM - OSL). The LM - OSL measurements were performed at room temperature and at 125 deg. C. All OSL signals were deconvolved into their individual components. Comparison of OSL curves after alpha and beta irradiation strongly supports that quartz OSL components follow first order kinetics in both cases. In the case of TL, the relative alpha to beta response is found to be very different for each TL glow-peak, but it does not depend strongly on irradiation dose. In the case of LM - OSL measurements, it is found that the relative behaviour of the alpha to beta response is different for three distinct regions, namely the fast OSL component, the region of medium OSL component originating from the TL glow-peak at 110 deg. C when stimulation takes place at room temperature and finally the region of slow OSL component. Following stimulation at ambient temperature, the relative alpha to beta response of all components was not observed to depend significantly on dose, with the value of ratio being 0.03 and a tendency to decrease with increasing dose. However, in the case of measurements performed at 125 deg. C, the relative response of the fast components is much enhanced, and for the remaining components it increases with increasing dose. Special care must be taken to examine the relative alpha to beta response of the fast component at 125 deg. C which contrasts the relative response of the TL peak at ca. 325 deg. C. The implications for the dating of annealed quartz are also briefly discussed. - Highlights: → Relative alpha to beta response for TL and LM-OSL is studied in annealed

  20. Study of Optically Stimulated Luminescence of LiF:Mg,Ti for beta and gamma dosimetry

    International Nuclear Information System (INIS)

    Matsushima, Luciana C.; Veneziani, Glauco R.; Campos, Letícia L.

    2013-01-01

    Modern advances in radiation medicine – radiodiagnosis, radiotherapy and interventional radiography – each present dosimetry challenges for the medical physicist that did not exist previously. In all of these areas a constant balance has to be made between the treatment necessary to destroy the tumor and the unnecessary exposure of healthy tissue. Innovative applications of OSL dosimetry are now appearing in each of these areas to help the medical physicist and oncologist design the most effective, and least deleterious, treatment for their patients. High sensitivity, precise delivery of light, fast readout times, simpler readers and easier automation are the main advantages of OSL in comparison with TLD. This work aimed to study the application of OSL technique using lithium fluoride dosimeters doped with magnesium and titanium (LiF:Mg,Ti) for application in beta and gamma dosimetry. -- Highlights: •Study of Optically Stimulated Luminescence of LiF:Mg,Ti and microLiF:Mg,Ti. •OSL response of TLD-100 dosimeters to beta and gamma radiation. •Analysis of repeatability and lowest levels of detection of detectors LiF:Mg,Ti

  1. Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter

    International Nuclear Information System (INIS)

    Preciado-Flores, S.; Schreck, M.; Melendrez, R.; Chernov, V.; Bernal, R.; Cruz-Vazquez, C.; Cruz-Zaragoza, E.; Barboza-Flores, M.

    2006-01-01

    Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 μm thick CVD diamond (polycrystalline diamond films prepared by chemical vapor deposition) film were studied in order to test its performance as a beta radiation dosemeter. The TL response is composed of four main TL glow peaks; two of these are in the range of 150-200 deg. C and two additional peaks in the 250-400 deg. C temperature range. The integrated TL as a function of radiation dose is linear up to 100 Gy and increases with increasing dose exposure. The dose dependence of the integrated OSL exhibits a similar behavior. The observed OSL/TL behavior for the CVD diamond film clearly demonstrate its capability for applications in radiation dosimetry with special relevance in medical dosimetry owing to the diamond's intrinsic material properties. (authors)

  2. Single-grain and multi-grain OSL dating of river terrace sediments in the Tabernas Basin, SE Spain

    DEFF Research Database (Denmark)

    Geach, M.R.; Thomsen, Kristina Jørkov; Buylaert, Jan-Pieter

    2015-01-01

    River terraces represent important records of landscape response to e.g. base-level change and tectonicmovement. Both these driving forces are important in the southern Iberian Peninsula. In this study,Optically Stimulated Luminescence (OSL) dating was used to date two principal river terraces...

  3. Intracavitary in vivo dosimetry based on multichannel fiber-coupled optically stimulated luminescence (OSL) of Al2O3:C for Curietherapy

    International Nuclear Information System (INIS)

    Spasic, Estelle

    2012-01-01

    The brachytherapy is an old technique using sealed radioactive sources of low or average energy. This technique is still therapeutically and economically relevant today and always evolving (e.g. High Dose Rate (HDR) brachytherapy). This treatment enables to deliver a high dose of irradiation in a limited tumoral volume and enables to minimize the risk of radiation-induced cancer as preserving the Organs at Risks (OAR). However, this technique generates high dose gradients, which makes in vivo dosimetry difficult to implement. Hence, the deviations observed between doses delivered and prescribed are often up to the maximal deviation tolerated by the nuclear safety regulations (± 5%) in conformational radiotherapy. Those regulations have been made mandatory in France since 2011. This thesis has been done within the framework of the ANR-TECSAN INTRADOSE project and is based on the past technological benefits demonstrated during the MAESTRO European project and the ANR-TECSAN CODOFER project, in particular a RL/OSL multichannel instrumentation (Radioluminescence - Optically Stimulated Luminescence) made and validated in preclinical evaluation during the MAESTRO project. The purpose of the INTRADOSE project is to demonstrate the feasibility of the intracavitary In Vivo Dosimetry (IVD) by dosimetric catheter using optical fibers and alumina crystals Al 2 O 3 :C with the aim of improving the safety of patients treated by HDR brachytherapy. This new probe enables to measure a dose distribution (several points) close to the OAR, it offers a little diameter (≤ 3 mm) designed for an intracavitary use (e.g. to insert in the urethra), it is transparent, radiation stable and reusable after dose reading and sterilization. During this study, we have first developed this new dosimetric sensor based on the OSL using the properties of the alumina crystal. Several tests have been done in order to evaluate the feasibility and the compatibility with a medical application. Then

  4. Infrared stimulated luminescence dating of an Eemian (MIS 5e) site in Denmark using K-feldspar

    DEFF Research Database (Denmark)

    Buylaert, Jan-Pieter; Huot, Sebastian; Murray, Andrew S.

    2011-01-01

    Infrared stimulated luminescence (IRSL) dating of K-feldspars may be an alternative to quartz optically stimulated luminescence (OSL) dating when the quartz OSL signal is too close to saturation or when the quartz luminescence characteristics are unsuitable. In this paper, Eemian (MIS 5e) coastal...

  5. Thermoluminescence and optically stimulated luminescence properties of nanocrystalline Er3+ and Yb3+ doped Y3Al5O12 exposed to β-rays

    International Nuclear Information System (INIS)

    RodrIguez, R A; Rosa, E de la; Salas, P; Melendrez, R; Barboza-Flores, M

    2005-01-01

    The thermoluminescence (TL) and optically stimulated luminescence (OSL) characterization of Er 3+ and Yb 3+ doped Y 3 Al 5 O 12 nanocrystalline samples prepared by the precipitation process and exposed to β-rays are discussed. The TL as well as the OSL were two orders of magnitude higher in Er 3+ doped than in Yb 3+ specimens. The charge trapping and the radiative thermally stimulated recombination processes in Y 3 Al 5 O 12 : Er 3+ involve four trapping states at 166, 243, 342 and 424 deg. C, but just two trapping levels at 219 and 413 deg. C for Y 3 Al 5 O 12 : Yb 3+ at a heating rate of 10 deg. C s -1 . The photostimulation with 470 nm light causes in both phosphors a radiative recombination of the optically free charge carriers belonging to the same trapping states. The TL and the OSL as a function of radiation dose behaviour were linear in the 10-100 Gy dose range. The results provide evidence of the potential uses of these materials in radiation storage and dosimeter devices

  6. Optically stimulated luminescence of ZnO obtained by thermal treatment of ZnS chemically synthesized; Luminiscencia opticamente estimulada de ZnO obtenido por tratamiento termico de ZnS sintetizado quimicamente

    Energy Technology Data Exchange (ETDEWEB)

    Cruz V, C.; Burruel I, S.E.; Orante B, V.R.; Grijalva M, H.; Perez S, R.; Bernal, R. [Universidad de Sonora, A.P. 130, Hermosillo (Mexico)

    2005-07-01

    In this work, we report the optically stimulated luminescence (OSL) dosimetry of new nano phosphors of ZnO obtained by thermal annealing of chemically synthesized ZnS powder. The synthesized ZnS nano powder was compressed in order to form pellet shaped pellets, which were afterwards subjected to a thermal annealing at 700 C during 24 h under air atmosphere. X-ray diffraction (XRD) patterns and energy-disperse X-ray Spectrometry (EDS) analyses confirmed the transformation of ZnS to ZnO. Samples were exposed to several doses of beta radiation up to 600 Gy, and the optically stimulated luminescence with 470 nm wavelength light was recorded as a function of dose. The intensity of the OSL signal increases by increasing dose, for what it is concluded that these new phosphor materials are suitable to be used in optically stimulated luminescence dosimetry. (Author)

  7. Pure thermal sensitisation and pre-dose effect of OSL in both unfired and annealed quartz samples

    Energy Technology Data Exchange (ETDEWEB)

    Oniya, Ebenezer O., E-mail: ebenezer.oniya@aaua.edu.ng [Physics and Electronics Department, Adekunle Ajasin University, 342111 Akungba Akoko (Nigeria); Polymeris, George S. [Institute of Nuclear Sciences, Ankara University, Beşevler 06100, Ankara (Turkey); Jibiri, Nnamdi N. [Department of Physics, University of Ibadan, Ibadan (Nigeria); Tsirliganis, Nestor C. [Department of Archaeometry and Physicochemical Measurements, R.C. ‘Athena’, P.O. Box 159, Kimmeria University Campus, 67100 Xanthi (Greece); Babalola, Israel A. [Department of Physics, University of Ibadan, Ibadan (Nigeria); Kitis, George [Nuclear Physics Laboratory, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece)

    2017-06-01

    The sensitisation of quartz has attracted much attention since its thorough understanding is important in luminescence studies and dating applications. The present investigation examines the influence of pure thermal activation and predose treatments on the sensitisation of different components of linearly modulated optically stimulated luminescence (LM-OSL) measured at room temperature (RT) thereby eliminating undesired thermal quenching effects. Annealed and unfired quartz samples from Nigeria were used. The OSL measurements were carried out using an automated RISØTL/OSL reader (model-TL/OSL–DA–15). A new approach was adopted to match each of the resolved components of the RT-LM-OSL to respective thermoluminescence (TL) peaks that share the same electron trap and recombination centers. Pure thermal activation and pre-dose treatments respectively affect the sensitisation of all the components of the RT-LM-OSL in a similar manner as the one reported for the 110 °C TL peak but without thermal quenching contributions. Component C4 in annealed samples that was identified to share the same electron trap and recombination centers with the 110 °C TL peak was also proved appropriate for RT-LM-OSL, instead of the initial part of the continuous wave (CW) OSL signal, thus the methods can serve as complementary dating methods.

  8. Pure thermal sensitisation and pre-dose effect of OSL in both unfired and annealed quartz samples

    International Nuclear Information System (INIS)

    Oniya, Ebenezer O.; Polymeris, George S.; Jibiri, Nnamdi N.; Tsirliganis, Nestor C.; Babalola, Israel A.; Kitis, George

    2017-01-01

    The sensitisation of quartz has attracted much attention since its thorough understanding is important in luminescence studies and dating applications. The present investigation examines the influence of pure thermal activation and predose treatments on the sensitisation of different components of linearly modulated optically stimulated luminescence (LM-OSL) measured at room temperature (RT) thereby eliminating undesired thermal quenching effects. Annealed and unfired quartz samples from Nigeria were used. The OSL measurements were carried out using an automated RISØTL/OSL reader (model-TL/OSL–DA–15). A new approach was adopted to match each of the resolved components of the RT-LM-OSL to respective thermoluminescence (TL) peaks that share the same electron trap and recombination centers. Pure thermal activation and pre-dose treatments respectively affect the sensitisation of all the components of the RT-LM-OSL in a similar manner as the one reported for the 110 °C TL peak but without thermal quenching contributions. Component C4 in annealed samples that was identified to share the same electron trap and recombination centers with the 110 °C TL peak was also proved appropriate for RT-LM-OSL, instead of the initial part of the continuous wave (CW) OSL signal, thus the methods can serve as complementary dating methods.

  9. Single-grain quartz OSL dating of debris flow deposits from Men Tou Gou, south west Beijing, China

    DEFF Research Database (Denmark)

    Zhao, Qiuyue; Thomsen, Kristina Jørkov; Murray, A. S.

    2017-01-01

    of the return frequency of these debris flows, risk assessment and climate change research. In this project, we use quartz single-grain optically stimulated luminescence (OSL) methods to determine the burial ages of five debris flow samples from the Zhai Tang region -60 km west of Beijing. OSL characteristics...... poorly bleached prior to deposition; relative over-dispersions are larger than 60%. Minimum age modelling indicates that all five samples were deposited within the past few hundred years, indicating that catastrophic debris flows are occurring under the historically-recent land-use pattern....

  10. Luminescence characteristics of quartz from the Southern Kenyan Rift Valley: Dose estimation using LM-OSL SAR

    International Nuclear Information System (INIS)

    Choi, J.H.; Duller, G.A.T.; Wintle, A.G.; Cheong, C.-S.

    2006-01-01

    Linearly modulated (LM) optically stimulated luminescence (OSL) measurements have revealed that some sedimentary quartz samples from the Kenyan Rift Valley do not have a fast OSL component, but contain a medium component and several slow components. It was impossible to recover a known dose for these samples using the conventional single-aliquot regenerative-dose (SAR) procedure. The dose-response curves and continuous wave (CW) OSL decay curves for these samples showed several undesirable properties for dating. We have compared various luminescence characteristics of these samples with other quartz samples from elsewhere in the world for which the SAR procedure has been shown to be appropriate; the latter were dominated by a fast OSL component. The characteristics include photoionisation cross-sections for each component and the relative proportions of the different components in the initial and total OSL signals. It was found that those samples that had greater than 90% of the initial 0.8 s of their OSL signal from the fast component were suitable for dating using the conventional SAR protocol. A novel method of displaying the relative contributions of the different OSL components in a ternary diagram is proposed. The thermal stability of each component was investigated using pulse-annealing experiments. We then examined the possibility of applying an LM-OSL SAR protocol to samples that have a substantial medium component

  11. The thermoluminescence and optically stimulated luminescence properties of Cr-doped alpha alumina transparent ceramics

    International Nuclear Information System (INIS)

    Liu, Qiang; Yang, Qiu Hong; Zhao, Guang Gen; Lu, Shen Zhou; Zhang, Hao Jia

    2013-01-01

    Highlights: •Polycrystalline Cr:α-Al 2 O 3 transparent ceramics were obtained with vacuum sintering method. •The influence of different concentration of Cr 2 O 3 on the thermoluminescence and optical stimulated luminescence properties of Cr:α-Al 2 O 3 transparent ceramics was studied. •It had a main peak at 503 K of very high intensity and linear concentration dependence up to high concentration. •It showed so interesting results with high TL sensitivity and high stability of OSL signal that Cr:α-Al 2 O 3 transparent ceramics might be a promising material in TL dosimetry and replace Cr:α-Al 2 O 3 crystals. -- Abstract: Polycrystalline Cr:α-Al 2 O 3 transparent ceramics were fabricated by conventional solid-state processing under vacuum condition. The SEM microstructure photographs of Cr:α-Al 2 O 3 transparent ceramics doped with different content of Cr 2 O 3 were investigated. The absorption, emission spectra, thermoluminescence and optical stimulated luminescence of Cr:α-Al 2 O 3 transparent ceramics were comparable to those of Cr:α-Al 2 O 3 crystals. The influence of different concentration of Cr 2 O 3 on the thermoluminescence and optical stimulated luminescence properties of Cr:α-Al 2 O 3 transparent ceramics was discussed. It showed so interesting results with high TL sensitivity and high stability of OSL signal that Cr:α-Al 2 O 3 transparent ceramics might be a promising material in TL dosimetry and replace Cr:α-Al 2 O 3 crystals

  12. SSDL Preparation for Implementation of the Use of OSL Dosimeters in Malaysia

    International Nuclear Information System (INIS)

    Sangau, J.K.; Taiman Kadni; Ahmad Bazlie Abdul Kadir

    2013-01-01

    Since the early 1980's, film badge has been widely used as a device of personal dose monitoring in Malaysia. Secondary Standard Dosimetry Laboratory (SSDL), as a service center for film badge has obtained the supply of personal monitoring film from Agfa Gevaert, Belgium every year. As the uses of film badge have some weaknesses, it has prompted SSDL to find an alternative dosimeter to replace the film badge. Based on the studies that have been conducted, SSDL has selected OSL dosimeter (Optically Stimulated Luminescent Dosimeter) to replace the film badge and is expected to be fully operational by middle of 2015. This paper aims to explain the selection of OSL dosimeter and planning carried out to ensure the success of their application in Malaysia. (author)

  13. Potential and limits of OSL, TT-OSL, IRSL and pIRIR290 dating methods applied on a Middle Pleistocene sediment record of Lake El'gygytgyn, Russia

    Directory of Open Access Journals (Sweden)

    A. Zander

    2013-03-01

    Full Text Available This study tests the paleomagnetic and proxy-data based Mid- to Upper Pleistocene sediment deposition history of Lake El'gygytgyn by applying different approaches of luminescence dating techniques on sediment cores taken from the centre of the 175 m deep lake. For dating polymineral and quartz fine grains (4–11 μm grain size range were extracted from nine different levels from the upper 28 m of sediment cores 5011-1A and 5011-1B. According to the independent age model, the lowest sample from 27.8–27.9 m below lake bottom level correlates to the Brunhes-Matuyama (B/M reversal. Polymineral sub-samples were analysed by infra-red stimulated luminescence (IRSL and post-IR IRSL measured at 290 °C (pIRIR290 using single aliquot regenerative dose (SAR sequences. SAR protocols were further applied to measure the blue light optically stimulated luminescence (OSL and thermally-transferred OSL (TT-OSL of fine-grained quartz supplemented by a multiple aliquot approach. Neither low temperature IRSL measurements at 50 °C nor any OSL dating approach on quartz yielded reliable results. Deconvolution of their dose response curves revealed a pseudo-increase of the dose response curves and explains the observed underestimation. The pIRIR protocol applied to polymineral fine grains was the only luminescence technique able to provide dating results of acceptable accuracy up to ca. 700 ka when correlated to the existing proxy-data and paleomagnetic based age record. We present the potential and limits of the different dating techniques and a correlation of pIRIR290 results with the proxy-data based age model.

  14. TL and OSL studies on lithium borate single crystals doped with Cu and Ag

    International Nuclear Information System (INIS)

    Rawat, N.S.; Kulkarni, M.S.; Tyagi, M.; Ratna, P.; Mishra, D.R.; Singh, S.G.; Tiwari, B.; Soni, A.; Gadkari, S.C.; Gupta, S.K.

    2012-01-01

    Lithium borate (LBO) single crystals doped with Cu and Ag (0.25 mol% each) (Li 2 B 4 O 7 :Cu,Ag) are grown by the Czochralski method. The thermoluminescence readout on Li 2 B 4 O 7 :Cu,Ag crystals showed three glow peaks at∼375, 441 and 516 K for the heating rate of 1 K/s. The thermoluminescence sensitivity of the grown Li 2 B 4 O 7 :Cu,Ag single crystals is found to be 5 times TLD-100 and a linear dose response in the range 1 mGy to 1 kGy. The glow curve deconvolution reveals nearly first order kinetics for all the three peaks with trap depths 0.77, 1.25 and 1.34 eV respectively and corresponding frequency factors 1.6×10 9 , 1.3×10 13 and 6.8×10 11 s −1 . The continuous wave optically stimulated luminescence (CW-OSL) measurements were performed on the LBO:Cu,Ag single crystals using blue light stimulation. The traps responsible for the three thermoluminescence peaks in Li 2 B 4 O 7 :Cu,Ag are found to be OSL sensitive. The qualitative correlation between TL peaks and CW-OSL response is established. The photoluminescence studies show that in case of co-doping of Ag in LBO:Cu the emission at 370 nm in Cu states dominates over the transitions in Ag states implying doping of Ag plays a role as sensitizer when co-doped with Cu and increases overall emission. - Highlights: ► Growth of crack free single crystals of Li2B4O7 :Cu and Ag. ► Study of TL and OSL parameters for Li2B4O7 :Cu and Ag. ► Correlation of OSL with TL peaks. ► Optimization of OSL readout time with respect to residual TL.

  15. TL and OSL dosimetric properties of Opal gemstone for gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Antonio, Patrícia L.; Gronchi, Claudia C.; Oliveira, Raquel A.P.; Khoury, Helen J.; Caldas, Linda V.E.

    2016-01-01

    In this work, the response of the natural material Opal was studied in relation to its thermoluminescence (TL) and optically stimulated luminescence (OSL), after exposure to the gamma radiation of a "6"0Co source. The structure of the powdered Opal was verified using the X-ray diffraction, scanning electronic microscopy and energy-dispersive X-ray spectroscopy techniques. The material, in its stone form, was turned into powder and mixed to Teflon (also in powder) in three different concentrations, and then pellets were manufactured. The aim of this work was to evaluate the response of these pellets in high-doses of gamma radiation beams, and to observe their possible application as dosimeters, using the TL and OSL techniques. The dosimetric properties of the samples were analyzed by means of different tests, as: TL emission curves and OSL signal decay curves, reproducibility of TL and OSL response, minimum detectable dose, TL and OSL dose–response curves (5 Gy–10 kGy), and fading. The results obtained in this work, for the TL and OSL phenomena, demonstrated that the pellets of Opal + Teflon present an adequate performance e possibility of use as dosimeters in beams of high-dose gamma radiation. - Highlights: • The XRD, SEM and EDX techniques were used to investigate powdered Opal. • Pellets of three different concentrations of Opal and Teflon were studied. • The dosimetric properties of the Opal + Teflon pellets were verified. • TL and OSL techniques were used to analyze the characteristics of the pellets. • Pellets of concentration of 2:1 (Opal:Teflon) presented the most adequate results.

  16. Dependence of the anomalous fading of the TL and blue-OSL of fluorapatite on the occupancy of the tunnelling recombination sites

    International Nuclear Information System (INIS)

    Tsirliganis, N.C.; Polymeris, G.S.; Kitis, G.; Pagonis, V.

    2007-01-01

    The anomalous fading (AF) of thermoluminescence (TL) and optically stimulated luminescence (OSL) signals in Durango apatite is attributed to tunnelling effects. Electrons from the TL and OSL traps in this material are transferred, via a tunnelling effect, to the recombination sites. The availability of recombination sites for tunnelled electrons is of major importance for the degree of AF rate observed in this material. It is expected that a variation of the number of the electron recombination sites will be reflected in the experimentally measured AF rate. In the present work an investigation of the recombination sites for the tunnelled electrons is attempted by studying the AF effect using a special technique, in which the anomalously faded TL (OSL) is replaced by an equal amount of TL (OSL) induced by a beta dose

  17. A high sensitivity optically stimulated luminescence scanning system for measurement of single sand-sized grains

    DEFF Research Database (Denmark)

    Duller, G.A.T.; Bøtter-Jensen, L.; Kohsiek, P.

    1999-01-01

    An instrument has been designed for the routine analysis of the optically stimulated luminescence signal from single grains of sand. The system is capable of analysing over 3000 individual grains in a single measurement sequence, and the OSL signal from each grain can be read in less than 3 s....... The design principles are described, along with preliminary measurements that illustrate the operation of the system and its capabilities....

  18. Recent developments of optically stimulated luminescence materials and techniques for radiation dosimetry and clinical applications

    Directory of Open Access Journals (Sweden)

    Pradhan A

    2008-01-01

    Full Text Available During the last 10 years, optically stimulated luminescence (OSL has emerged as a formidable competitor not only to thermoluminescence dosimetry (TLD but also to several other dosimetry systems. Though a large number of materials have been synthesized and studied for OSL, Al 2 O 3 :C continues to dominate the dosimetric applications. Re-investigations of OSL in BeOindicate that this material might provide an alternative to Al 2 O 3 :C. Study of OSL of electronic components of mobile phones and ID cards appears to have opened up a feasibility of dosimetry and dose reconstruction using the electronic components of gadgets of everyday use in the events of unforeseen situations of radiological accidents, including the event of a dirty bomb by terrorist groups. Among the newly reported materials, a very recent development of NaMgF 3 :Eu 2+ appears fascinating because of its high OSL sensitivity and tolerable tissue equivalence. In clinical dosimetry, an OSL as a passive dosimeter could do all that TLD can do, much faster with a better or at least the same efficiency; and in addition, it provides a possibility of repeated readout unlike TLD, in which all the dose information is lost in a single readout. Of late, OSL has also emerged as a practical real-time dosimeter for in vivo measurements in radiation therapy (for both external beams and brachytherapy and in various diagnostic radiological examinations including mammography and CT dosimetry. For in vivo measurements, a probe of Al 2 O 3 :C of size of a fraction of a millimeter provides the information on both the dose rate and the total dose from the readout of radioluminescence and OSL signals respectively, from the same probe. The availability of OSL dosimeters in various sizes and shapes and their performance characteristics as compared to established dosimeters such as plastic scintillation dosimeters, diode detectors, MOSFET detectors, radiochromic films, etc., shows that OSL may soon become

  19. An application of artificial neural intelligence for personal dose assessment using a multi-area OSL dosimetry system

    International Nuclear Information System (INIS)

    Lee, S.-Y.Sang-Yoon.; Kim, B.-H.Bong-Hwan; Lee, K.J.Kun Jai

    2001-01-01

    Significant advances have been made in recent years to improve measurement technology and performance of phosphor materials in the fields of optically stimulated luminescence (OSL) dosimetry. Pulsed and continuous wave OSL studies recently carried out on α-Al 2 O 3 : C have shown that the material seems to be the most promising for routine application of OSL for dosimetric purposes. The main objective of the study is to propose a new personal dosimetry system using α-Al 2 O 3 : C by taking advantage of its optical properties and energy dependencies. In the process of the study, a new dose assessment algorithm was developed using artificial neural networks in hopes of achieving a higher degree of accuracy and precision in personal OSL dosimetry system. The original hypothesis of this work is that the spectral information of an X- and γ-ray fields may be obtained by the analysis of the response of a multi-element system. In this study, a feedforward neural network using the error back-propagation method with Bayesian optimization was applied for the response unfolding procedure. The validation of the proposed algorithm was investigated by unfolding the 10 measured responses of α-Al 2 O 3 : C for arbitrarily mixed photon fields which range from 20 to 662 keV

  20. Quartz OSL dating of late quaternary Chinese and Serbian loess: A cross Eurasian comparison of dust mass accumulation rates

    DEFF Research Database (Denmark)

    Peric, Zoran; Adolphi, Emma Lagerbäck; Stevens, Thomas

    2018-01-01

    on multi-millennial timescales, with no detailed examination of dust MAR at the two ends of the Eurasian loess belt on shorter, sub-orbital scales. Here we present a detailed quartz optically stimulated luminescence (OSL) chronology from the Serbian Titel Loess Plateau (Veliki Surduk loess core...

  1. Intercomparison of dispersed radiation readings among film dosimetry, electronic and OSL with X-rays for low dose; Intercomparacion de lecturas de radiacion dispersa entre dosimetria film, electronica y OSL con rayos X para dosis bajas

    Energy Technology Data Exchange (ETDEWEB)

    Andisco, D. [Universidad de Buenos Aires, Facultad de Medicina, Paraguay 2155, C1121AAA Buenos Aires (Argentina); Blanco, S. [CONICET, Saavedra 15, C1083ACA Buenos Aires (Argentina); Bourel, V.; Schmidt, L. [Universidad Favaloro, Facultad de Ciencias e Ingenieria, Solis 453, C1078AAI, Buenos Aires (Argentina); Di Risio, C., E-mail: dandisco@fmed.uba.ar [Universidad de Belgrano, Facultad de Ingenieria, Zabala 1837, C1426DQG, Buenos Aires (Argentina)

    2014-08-15

    One of the personal dosimetry methods more used for several decades is the dosimetry type film, characterized to possess readings with certain margin of trust. Today other methods exist that many times are presupposed more reliable due to the nature of the detection like the electronic dosimeters or the OSL (Optically Stimulated Luminescence) dosimetry. With the purpose of comparing different methods and to can determining the existent differences among each method has been carried out an intercomparison assay. The different dosimeters have been exposed to dispersed radiation generated by a Hemodynamics equipment of the type -arch in C- and a dispersing system of the primary beam. Film dosimeters have been used; OSL (In Light), OSL (Nano Dots) and Electronic with the purpose of knowing and to valorize the existent differences among its readings. Always, the intercomparison exercises have demonstrated to be an useful tool when establishing the measurement capacity and the quality of the results emitted by the laboratories of personal dosimetry services. Also, this type of assays allows obtaining quality indicators of the laboratory performance and they are habitual part of the procedures for accreditation of the same ones. The Optically Stimulated Luminescence is a technology that has grown in Argentina so much in the area of personal dosimetry as in dosimetry in vivo (radiotherapy area). In this intercomparison study, the answers corresponding to each technology were looked for oneself irradiation of the disperse type, that is to say, of very low energy. (Author)

  2. Thermoluminescence and optically stimulated luminescence properties of Dy3+-doped CaO-Al2O3-B2O3-based glasses

    Science.gov (United States)

    Yahaba, T.; Fujimoto, Y.; Yanagida, T.; Koshimizu, M.; Tanaka, H.; Saeki, K.; Asai, K.

    2017-02-01

    We developed Dy3+-doped CaO-Al2O3-B2O3 based glasses with Dy concentrations of 0.5, 1.0, and 2.0 mol% using a melt-quenching technique. The as-synthesized glasses were applicable as materials exhibiting thermoluminescence (TL) and optically stimulated luminescence (OSL). The optical and radiation response properties of the glasses were characterized. In the photoluminescence (PL) spectra, two emission bands due to the 4F9/2 → 6H15/2 and 4F9/2 → 6H13/2 transitions of Dy3+ were observed at 480 and 580 nm. In the OSL spectra, the emission band due to the 4F9/2 → 6H15/2 transition of Dy3+ was observed. Excellent TL and OSL responses were observed for dose ranges of 0.1-90 Gy. In addition, TL fading behavior was better than that of OSL in term of the long-time storage. These results indicate that the Dy3+-doped CaO-Al2O3-B2O3-based glasses are applicable as TL materials.

  3. A polymeric dosimeter film based on optically-stimulated luminescence for dose measurements below 1 kGy

    International Nuclear Information System (INIS)

    Kovacs, A.; Baranyai, M.; Wojnarovits, L.; Slezsak, I.; McLaughlin, W.L.; Miller, S.D.; Miller, A.; Fuochi, P.G.; Lavalle, M.

    1999-01-01

    A new potential dosimetry system 'Sunna' containing a microcrystalline dispersion of an optically-stimulated fluor in a plastic matrix has been recently developed to measure and image high doses. Our previous investigations have revealed that the new dosimeter system is capable of measuring absorbed doses in the dose range of 1-100 kGy. The optically-stimulated luminescence (OSL) analysis is based on the blue light stimulation of the colour center states produced upon irradiation, and the intensity of the resulting red-light emission is used to measure absorbed dose. This analysis is carried out with a simple table-top fluorimeter developed for this purpose having also the ability to calculate the mathematical formula of the calibration function. The Sunna dosimeter was recently investigated for potential use in lower dose range below 1 kGy. These investigations have shown that the film is suitable for measuring doses in the range of 1-1000 Gy for both electron and gamma radiation. To test the applicability of the film, its reproducibility, stability, sensitivity to ambient and UV light and irradiation temperature were measured. The stability of the dosimeter was investigated by monitoring the change of the OSL signal with storage time after irradiation. Further experiments proved the homogeneity of the film with respect to thickness variation, and limited differences in its response were found between batches. (author)

  4. OSL properties of three commonly available salt brands in India for its use in accident dosimetry

    Science.gov (United States)

    Singh, A. K.; Menon, S. N.; Kadam, S. Y.; Koul, D. K.; Datta, D.

    2018-03-01

    Thermally stimulated luminescence (TL) and Optically Stimulated Luminescence (OSL) characterization of three commonly available salt brands in India were undertaken for their application in accident dosimetry. The investigations showed that the luminescence properties differed to some extent with that reported in literature. Dosimetric properties of these salt samples showed that these can be useful in accident dosimetry. Based on the sensitization and fading behaviour of the samples a Single Aliquot Regenerative (SAR) protocol has been proposed for dose estimation.

  5. Attaining provenance proxies from OSL and TL sensitivities: Coupling with grain size and heavy minerals data from southern Brazilian coastal sediments

    International Nuclear Information System (INIS)

    Zular, André; Sawakuchi, André O.; Guedes, Carlos C.F.; Giannini, Paulo C.F.

    2015-01-01

    In the São Francisco do Sul (SFS) barrier in southern Brazil, the optically stimulated luminescence (OSL) and thermoluminescence (TL) sensitivities of coastal sands vary according to geomorphological units. Sands from older beach ridges (ages older than 2000 years ago) show higher OSL and TL sensitivities than younger units (ages younger than 2000 years). Geomorphological units in the SFS attest to changes in provenance as a result of a coastal climate shift evidenced through grain size and heavy mineral analysis. We argue that in the SFS barrier sands, OSL and TL sensitivity signals provide an additional proxy to climate events and can be used as an alternative method to assess changes in provenance and tracking source-to-sink systems to monitor past and future environmental changes. - Highlights: • OSL and TL sensitivities are confronted with grain size and heavy minerals data. • We report OSL and 110 °C TL sensitivities as provenance proxies. • 110 °C TL sensitivity outlines environmental changes better than OSL sensitivity data.

  6. On the use of OSL of wire-bond chip card modules for retrospective and accident dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Woda, Clemens [Helmholtz Zentrum Muenchen - German Research Centre for Environmental Health, Institute of Radiation Protection, Ingolstaedter Landstrasse 1, D-85764 Neuherberg (Germany)], E-mail: clemens.woda@helmholtz-muenchen.de; Spoettl, Thomas [Infineon Technologies AG, Wernerwerkstrasse 1, D-93049 Regensburg (Germany)

    2009-05-15

    The potential of optically stimulated luminescence of wire-bond chip card modules, used in health insurance, ID, cash and credit cards for retrospective and accident dosimetry is investigated. Chip card modules obtained directly from the producer, using a widely spread UV-cured epoxy product for encapsulation, are used as basis for the study. The radiation sensitivity is due to silica grains added to the epoxy for controlling the thixotropic properties. Luminescence properties are complex due to the presumed thermo-optical release of electrons from the epoxy and transfer into the silica. Best results and highest sensitivity are obtained by using no or only low preheat treatments. A high degree of fading of the OSL signal during storage at room temperature is observed, which is tentatively explained by the superposition of thermal decay of shallow OSL traps and athermal (anomalous) decay of deeper OSL traps. The dose response of the OSL signal shows exponentially saturating behaviour, with saturation doses of 77 Gy or 9.6 Gy, depending on pretreatment. Dose recovery tests show that given doses can be recovered within a deviation of {+-}14%, if measured signals are corrected for fading. The minimum detectable dose is estimated at {approx}3 mGy, {approx}10 mGy and {approx}20 mGy for readouts immediately, 1 day and 10 days after exposure, respectively.

  7. On the use of OSL of wire-bond chip card modules for retrospective and accident dosimetry

    International Nuclear Information System (INIS)

    Woda, Clemens; Spoettl, Thomas

    2009-01-01

    The potential of optically stimulated luminescence of wire-bond chip card modules, used in health insurance, ID, cash and credit cards for retrospective and accident dosimetry is investigated. Chip card modules obtained directly from the producer, using a widely spread UV-cured epoxy product for encapsulation, are used as basis for the study. The radiation sensitivity is due to silica grains added to the epoxy for controlling the thixotropic properties. Luminescence properties are complex due to the presumed thermo-optical release of electrons from the epoxy and transfer into the silica. Best results and highest sensitivity are obtained by using no or only low preheat treatments. A high degree of fading of the OSL signal during storage at room temperature is observed, which is tentatively explained by the superposition of thermal decay of shallow OSL traps and athermal (anomalous) decay of deeper OSL traps. The dose response of the OSL signal shows exponentially saturating behaviour, with saturation doses of 77 Gy or 9.6 Gy, depending on pretreatment. Dose recovery tests show that given doses can be recovered within a deviation of ±14%, if measured signals are corrected for fading. The minimum detectable dose is estimated at ∼3 mGy, ∼10 mGy and ∼20 mGy for readouts immediately, 1 day and 10 days after exposure, respectively.

  8. Combining infrared- and green-laser stimulation sources in single-grain luminescence measurements of feldspar and quartz

    DEFF Research Database (Denmark)

    Duller, G.A.T.; Bøtter-Jensen, L.; Murray, A.S.

    2003-01-01

    A system designed for measurement of the optically stimulated luminescence (OSL) from individual sand-sized mineral grains has been constructed. Previously, this system was equipped only with a green laser emitting at 532 run, but now an infrared (IR) laser at 830 run has been added. It is now...... possible to interchangeably use the two laser sources for optical stimulation. This is especially valuable for the measurement of feldspars. The power density using the IR laser at the grain is similar to500 W cm(-2), and stimulation for 1 s reduces the OSL signal to near background level. Initial results...

  9. Development of optically stimulated luminescence techniques using natural minerals and ceramics, and their application to retrospective dosimetry

    International Nuclear Information System (INIS)

    Boetter-Jensen, L.

    2000-09-01

    This thesis summarises research and development of optically stimulated luminescence (OSL) and its applications by the author at Risoe National Laboratory, up to 1999. These developments have been directed primarily at retrospective accident dosimetry and luminescence dating. Experimental investigations include the studies of OSL properties of the natural minerals quartz and feldspars and the artificial materials porcelain and aluminium oxide (Al 2 O 3 ). Blue light emitting diodes and infrared laser diodes are shown to provide simple and practical alternatives to broad-band light and visible laser stimulation. The development of OSL apparatus designed for the rapid measurement of single grains of phosphors also opens up a new area of luminescence measurement, allowing the detailed examination of dose distributions within a multiple-grain sample. This is of particular importance to the studies of incompletely reset geological sediments, and to accident dosimetry measurements using unheated materials. Al 2 O 3 :C single crystals are tested as environmental OSL dosemeters for assessing both the natural background photon radiation dose rates in the field and the natural dose rates inside bricks collected for accident dose evaluation. Environmental doses of the order of few μGy are measured with high precision. UV photo-stimulated luminescence spectra obtained from porcelain samples are used to confirm that the main component responsible for the OSL signal from porcelain is Al 2 O 3 . OSL single-aliquot regenerative-dose (SAR) techniques are used with quartz extracted from Chernobyl bricks to determine the accrued dose after the accident. This has improved the measurement precision significantly, from about 5-6 % using traditional methods to now less than 2 %. Depth-dose profiles measured in Chernobyl bricks are compared with those obtained in the laboratory using different gamma sources and these comparisons show that the average energy of the accident radiation was

  10. Development of optically stimulated luminescence techniques using natural minerals and ceramics, and their application to retrospective dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Boetter-Jensen, L

    2000-09-01

    This thesis summarises research and development of optically stimulated luminescence (OSL) and its applications by the author at Risoe National Laboratory, up to 1999. These developments have been directed primarily at retrospective accident dosimetry and luminescence dating. Experimental investigations include the studies of OSL properties of the natural minerals quartz and feldspars and the artificial materials porcelain and aluminium oxide (Al{sub 2}O{sub 3}). Blue light emitting diodes and infrared laser diodes are shown to provide simple and practical alternatives to broad-band light and visible laser stimulation. The development of OSL apparatus designed for the rapid measurement of single grains of phosphors also opens up a new area of luminescence measurement, allowing the detailed examination of dose distributions within a multiple-grain sample. This is of particular importance to the studies of incompletely reset geological sediments, and to accident dosimetry measurements using unheated materials. Al{sub 2}O{sub 3}:C single crystals are tested as environmental OSL dosemeters for assessing both the natural background photon radiation dose rates in the field and the natural dose rates inside bricks collected for accident dose evaluation. Environmental doses of the order of few {mu}Gy are measured with high precision. UV photo-stimulated luminescence spectra obtained from porcelain samples are used to confirm that the main component responsible for the OSL signal from porcelain is Al{sub 2}O{sub 3}. OSL single-aliquot regenerative-dose (SAR) techniques are used with quartz extracted from Chernobyl bricks to determine the accrued dose after the accident. This has improved the measurement precision significantly, from about 5-6 % using traditional methods to now less than 2 %. Depth-dose profiles measured in Chernobyl bricks are compared with those obtained in the laboratory using different gamma sources and these comparisons show that the average energy of

  11. Optically stimulated luminescence of electronic components for forensic, retrospective, and accident dosimetry

    International Nuclear Information System (INIS)

    Inrig, E.L.; Godfrey-Smith, D.I.; Khanna, S.

    2008-01-01

    This study investigated the optically stimulated luminescence (OSL) response of electronic components found within portable electronic devices such as cell phones and pagers, portable computers, music and video players, global positioning system receivers, cameras, and digital watches. The analysis of components extracted from these ubiquitous devices was proposed for applications ranging from rapid accident dose reconstruction to the tracking and attribution of gamma-emitting radiological materials. Surface-mount resistors with alumina porcelain substrates consistently produced OSL following irradiation, with minimum detectable doses on the order of 10 mGy for a typical sample. Since the resistor ceramics were found to exhibit anomalous fading, dose reconstruction procedures were developed to correct for this using laboratory measurements of fading rates carried out over approximately 3 months. Two trials were conducted in which cellular phones were affixed to an anthropomorphic phantom and irradiated using gamma-ray sources; ultimately, analysis of the devices used in these trials succeeded in reconstructing doses in the range of 0.1-0.6Gy

  12. SU-E-T-75: Commissioning Optically Stimulated Luminescence Dosimeters for Fast Neutron Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Young, L [UniversityWashington, Seattle, WA (United States); Yang, F; Sandison, G [University of Washington, Seattle, WA (United States); Woodworth, D [University of California, Santa Barbara, Santa Barbara, CA (United States); McCormick, Z [University of Nevada - Reno, Reno, Nevada (United States)

    2014-06-01

    Purpose: Fast neutrons therapy used at the University of Washington is clinically proven to be more effective than photon therapy in treating salivary gland and other cancers. A nanodot optically stimulated luminescence (OSL) system was chosen to be commissioned for patient in vivo dosimetry for neutron therapy. The OSL-based radiation detectors are not susceptible to radiation damage caused by neutrons compared to diodes or MOSFET systems. Methods: An In-Light microStar OSL system was commissioned for in vivo use by radiating Landauer nanodots with neutrons generated from 50.0 MeV protons accelerated onto a beryllium target. The OSLs were calibrated the depth of maximum dose in solid water localized to 150 cm SAD isocenter in a 10.3 cm square field. Linearity was tested over a typical clinical dose fractionation range i.e. 0 to 150 neutron-cGy. Correction factors for transient signal fading, trap depletion, gantry angle, field size, and wedge factor dependencies were also evaluated. The OSLs were photo-bleached between radiations using a tungsten-halogen lamp. Results: Landauer sensitivity factors published for each nanodot are valid for measuring photon and electron doses but do not apply for neutron irradiation. Individually calculated nanodot calibration factors exhibited a 2–5% improvement over calibration factors computed by the microStar InLight software. Transient fading effects had a significant impact on neutron dose reading accuracy compared to photon and electron in vivo dosimetry. Greater accuracy can be achieved by calibrating and reading each dosimeter within 1–2 hours after irradiation. No additional OSL correction factors were needed for field size, gantry angle, or wedge factors in solid water phantom measurements. Conclusion: OSL detectors are a useful for neutron beam in vivo dosimetry verification. Dosimetric accuracy comparable to conventional diode systems can be achieved. Accounting for transient fading effects during the neutron beam

  13. Energy levels in YPO{sub 4}:Ce{sup 3+},Sm{sup 3+} studied by thermally and optically stimulated luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Bos, Adrie J.J., E-mail: a.j.j.bos@tudelft.n [Delft University of Technology, Mekelweg 15, NL 2629 JB Delft (Netherlands); Poolton, Nigel R.J. [Delft University of Technology, Mekelweg 15, NL 2629 JB Delft (Netherlands); Institute of Maths and Physics, Aberystwyth University, Aberystwyth SY23 3BZ (United Kingdom); Wallinga, Jakob [Netherlands Centre for Luminescence Dating, Delft University of Technology, Mekelweg 15, NL 2629 JB Delft (Netherlands); Bessiere, Aurelie [Ecole Nat. Superieure de Chimie de Paris, 11 Rue P et M Curie, 75231 Paris Cedex 05 (France); Dorenbos, Pieter [Delft University of Technology, Mekelweg 15, NL 2629 JB Delft (Netherlands)

    2010-03-15

    Energy-resolved optically stimulated luminescence (OSL) spectra and thermoluminescence (TL) glow curves of a powder sample of YPO{sub 4}:Ce{sup 3+},Sm{sup 3+} were measured to investigate the nature of the trapping centre and to locate its energy level relative to the valence and conduction bands of the YPO{sub 4} host. The high-temperature glow peak could unequivocally be assigned to Sm{sup 2+} (thus Sm{sup 3+} acts as an electron trap). The trap depth of this centre, as derived from the OSL excitation spectra, is in good agreement with the Dorenbos model prediction. The OSL excitation spectra also reveal excited states of Sm{sup 2+} well below the conduction band. These excited states produce a broadening of the high-temperature TL glow peak and also cause the activation energy determined by the Hoogenstraten method to underestimate the trap depth.

  14. Application of the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques to determinate the isodose curves in a cancer treatment planning simulation using Volumetric Modulated Arc Therapy - VMAT

    International Nuclear Information System (INIS)

    Bravim, Amanda

    2015-01-01

    The Volumetric Modulated Arc Therapy (VMAT) is an advance technique of Intensity Modulated Radiation Therapy (IMRT). This progress is due to the continuous gantry rotation with the radiation beam modulation providing lower time of the patient treatment. This research aimed the verification of the isodose curves in a simulation of a vertebra treatment with spinal cord protection using the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques and the LiF:Mg,Ti (TLD-100), CaS0 4 :Dy and Al 2 0 3 :C dosimeters and LiF:Mg,Ti micro dosimeters (TLD-100). The dosimeters were characterized using PMMA plates of 30 x 30 x 30 cm 3 and different thickness. All irradiations were done using Truebeam STx linear accelerator of Hospital Israelita Albert Einstein, with 6 MV photons beam. After the dosimeter characterization, they were irradiated according the specific planning simulation and using a PMMA phantom developed to VMAT measurements. This irradiation aimed to verify the isodose curves of the treatment simulation using the two dosimetry techniques. All types of dosimeters showed satisfactory results to determine the dose distribution but analysing the complexity of the isodose curves and the proximity of them, the LiF:Mg,Ti micro dosimeter showed the most appropriate for use due to its small dimensions. Regarding the best technique, as both technique showed satisfactory results, the TL technique presents less complex to be used because the most of the radiotherapy departments already have a TL laboratory. The OSL technique requires more care and greater investment in the hospital. (author)

  15. Effect of high-dose irradiation on the optically stimulated luminescence of Al{sub 2}O{sub 3}:C

    Energy Technology Data Exchange (ETDEWEB)

    Yukihara, E.G. E-mail: yukihara@thor.phy.okstate.edu; Whitley, V.H.; McKeever, S.W.S. E-mail: swsm@okstate.edu; Akselrod, A.E.; Akselrod, M.S

    2004-06-01

    This paper examines the effect of high-dose irradiation on the optically stimulated luminescence (OSL) of Al{sub 2}O{sub 3}:C, principally on the shape of the OSL decay curve and on the OSL sensitivity. The effect of the degree of deep trap filling on the OSL was also studied by monitoring the sensitivity changes after doses of beta irradiation and after step-annealing of samples previously irradiated with high doses. The OSL response to dose shows a linear-supralinear-saturation behavior, with a decrease in the response for doses higher than those required for saturation. This behavior correlates with the sensitivity changes observed in the samples annealed only to 773 K, which show sensitization for doses up to 20-50 Gy and desensitization for higher doses. Data from the step-annealing study leads to the suggestion that the sensitization is caused by the filling of deep electron traps, which become thermally unstable at 1100-1200 K, whereas the desensitization is caused by the filling of deep hole traps, which become thermally unstable at 800-875 K, along with a concomitant decrease in the concentration of recombination centers (F{sup +}-centers). Changes in the shape of the OSL decay curves are also observed at high doses, the decay becoming faster as the dose increases. These changes in the OSL decay curves are discussed in terms of multiple overlapping components, each characterized by different photoionization cross-sections. However, using numerical solutions of the rate equations for a simple model consisting of a main trap and a recombination center, it is shown that the kinetics of OSL process may also be partially responsible for the changes in the OSL curves at high doses in Al{sub 2}O{sub 3}:C. Finally, the implication of these results for the dosimetry of heavy charged particles is discussed.

  16. Resetting of Quartz OSL (optically stimulated luminescence) Signals by Frictional Heating in Experimentally Sheared Gouges at Seismic Slip Rates.

    Science.gov (United States)

    Kim, J. H.; Choi, J. H.; Chauhan, N.; Lee, S.; Hirose, T.; Ree, J. H.

    2014-12-01

    Recent studies on natural and experimental seismic faults have revealed that frictional heating plays an important role in earthquake dynamics as well as in producing mineralogical and microstructural signatures of seismic faulting. Here, we report changes in OSL signals in quartz by frictional heating in experimental fault gouges. The gouges (80% of quartz and 20% of bentonite by weight) with a thickness of 1 mm were sheared between sandstone cylinders (diameter: 25 mm) at a normal stress of 1 MPa and slip rate of 1.31 m/s. The quartz grains from a sand dune on the western coast of South Korea were sieved to select size fractions between 90 and 250 μm. The equivalent dose (De) of the undeformed quartz grains was 8.0 ± 0.3 Gy. Upon displacement, the friction abruptly increases to the 1st peak (with friction coefficient μ ≈ 0.75) followed by slip weakening. Then the fault zones show two more peak frictions (μ ≈ 0.53~0.75) and finally reach a steady-state friction (μ ≈ 0.2~0.35). The fault can be divided into three zones based grain size (thus slip rate); slip localization (SLZ), intermediate slip-rate (ISZ) and low slip-rate (LSZ) zones. SLZ develops adjacent to the moving side of the sandstone cylinder with P-foliation and shear band. The size of quartz (Dq) in ISZ and LSZ is 5-30 μm and 50-250 μm, respectively. SEM and TEM analyses indicate that the fault gouge of SLZ consists of subangular quartz clasts (Dq ≈ 3 μm) and matrix of nano-scale quartz, unidentified silicate minerals and amorphous material. The fault zones were sectioned into six layers (~160 µm thick for each layer) parallel to the fault zone boundary for OSL analyses. Quartz grains from all the layers except the one immediately adjacent to the stationary side of the sandstone cylinder show De of 'effectively' 0 Gy indicating a full resetting of OSL signals. The partial resetting of OSL signal in the layer adjacent to the stationary side of the cylinder indicates the temperature (T

  17. Optically stimulated luminescence dating of archaeological ceramics from Osvaldo and Lago Grande sites in central Amazon

    International Nuclear Information System (INIS)

    Hazenfratz, Roberto; Tudela, Diego R.G.; Munita, Casimiro S.; Mittani, Juan C.R.; Tatumi, Sonia H.

    2013-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) dating are two important techniques for dating archaeological and geological material, especially suitable for archaeological ceramics, where samples for 14 C dating are not available. In this work, five pottery shards from Osvaldo and Lago Grande archaeological sites were dated by OSL. For measurements, it was used the SAR protocol. The annual dose rates were estimated by the contents of U, Th and K, determined by instrumental neutron activation analysis (INAA) of the pottery shards and clay samples near both sites. Lago Grande and Osvaldo represent a microcosm of the region, and their proximity and high density of archaeological record turn them interesting to study possible relations of cultural and/or commercial exchange. Calculations showed that the water content is an important variable that cannot be neglected in OSL dating of pottery shards from central Amazon, due to the high humidity in regional soils. The results between 867 ± 101 and 1154 ± 62 years AD agreed with the average time span for the archaeological sites occupation found in the literature. (author)

  18. Optically stimulated luminescence dating of archaeological ceramics from Osvaldo and Lago Grande sites in central Amazon

    Energy Technology Data Exchange (ETDEWEB)

    Hazenfratz, Roberto; Tudela, Diego R.G.; Munita, Casimiro S., E-mail: robertohm@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Mittani, Juan C.R.; Tatumi, Sonia H. [Universidade Federal de Sao Paulo (UNIFESP), Santos, SP (Brazil)

    2013-07-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) dating are two important techniques for dating archaeological and geological material, especially suitable for archaeological ceramics, where samples for {sup 14}C dating are not available. In this work, five pottery shards from Osvaldo and Lago Grande archaeological sites were dated by OSL. For measurements, it was used the SAR protocol. The annual dose rates were estimated by the contents of U, Th and K, determined by instrumental neutron activation analysis (INAA) of the pottery shards and clay samples near both sites. Lago Grande and Osvaldo represent a microcosm of the region, and their proximity and high density of archaeological record turn them interesting to study possible relations of cultural and/or commercial exchange. Calculations showed that the water content is an important variable that cannot be neglected in OSL dating of pottery shards from central Amazon, due to the high humidity in regional soils. The results between 867 ± 101 and 1154 ± 62 years AD agreed with the average time span for the archaeological sites occupation found in the literature. (author)

  19. Application of the OSL dosimetry technique in the identification of irradiated foods, such as condiments and spices

    International Nuclear Information System (INIS)

    Silva, Catherine C.O.; Alencar, Marcus A.V. de

    2013-01-01

    The use of ionizing radiation in food preservation is considered a well-established technique, so many countries, including Brazil, now allow the use of irradiated foods. Many methods have been tested for dosimetry and identification of irradiated foods including thermoluminescence, electron paramagnetic resonance, and others based on microbiological changes and in viscosity, and which requires a sample processing. The technique of optically stimulated luminescence (OSL) presents an advantage over other methods mentioned: The samples may be used without the need for a prior processing. This work aims to study the OSL properties of condiments and spices irradiated, in order to verify the possibility of the application of the OSL technique in identifying and dosimetry of irradiated foods. The samples used were of four kinds of spices: cumin, oregano, white pepper and black pepper. All samples were subjected to gamma irradiation from a Co-60 source with dose values of kerma in air of 100 Gy to 35 kGy. The samples of cumin presents the OSL signal, however, is only possible to identify whether the condiment was irradiated or not. The sample of oregano also presents the OSL signal, and for this condiment is possible to identify addition to its irradiation, the value of dose. The black pepper and white pepper samples don't presents the OSL signal. The results obtained in this study indicate the possibility of using the OSL technique for the identification and dosimetry of irradiated foods. (author)

  20. Intercomparison of dispersed radiation readings among film dosimetry, electronic and OSL with X-rays for low dose

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Bourel, V.; Schmidt, L.; Di Risio, C.

    2014-08-01

    One of the personal dosimetry methods more used for several decades is the dosimetry type film, characterized to possess readings with certain margin of trust. Today other methods exist that many times are presupposed more reliable due to the nature of the detection like the electronic dosimeters or the OSL (Optically Stimulated Luminescence) dosimetry. With the purpose of comparing different methods and to can determining the existent differences among each method has been carried out an intercomparison assay. The different dosimeters have been exposed to dispersed radiation generated by a Hemodynamics equipment of the type -arch in C- and a dispersing system of the primary beam. Film dosimeters have been used; OSL (In Light), OSL (Nano Dots) and Electronic with the purpose of knowing and to valorize the existent differences among its readings. Always, the intercomparison exercises have demonstrated to be an useful tool when establishing the measurement capacity and the quality of the results emitted by the laboratories of personal dosimetry services. Also, this type of assays allows obtaining quality indicators of the laboratory performance and they are habitual part of the procedures for accreditation of the same ones. The Optically Stimulated Luminescence is a technology that has grown in Argentina so much in the area of personal dosimetry as in dosimetry in vivo (radiotherapy area). In this intercomparison study, the answers corresponding to each technology were looked for oneself irradiation of the disperse type, that is to say, of very low energy. (Author)

  1. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon; Dosimetria Tl y OSL de peliculas de diamante CVD puras e impurificadas con boro-carbono

    Energy Technology Data Exchange (ETDEWEB)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M. [CIF, UNISON, A.P. 5-088, 83190 Hermosillo, Sonora (Mexico); Castaneda, B. [Departamento de Fisica, Universidad de Sonora, Apdo. Postal 1626, Hermosillo, Sonora (Mexico); Goncalves, J.A.N.; Sandonato, G.M. [Laboratorio Associado de Plasma, Instituto Nacional de Pesquisas Espaciais C.P. 515- 12201 -970, Sao Jose dos Campos, SP (Brazil); Cruz Z, E. [Instituto de Ciencias Nucleares, UNAM, Apdo. Postal 70-543, 04510 Mexico D.F. (Mexico); Preciado F, S.; Cruz V, C.; Brown, F. [Departamento de Investigacion en Polimeros y Materiales de la Universidad de Sonora, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Schreck, M. [Universitaet Augsburg, Institut fuer Physik D-86135 Augsburg (Germany)

    2004-07-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  2. Stability of fine-grained TT-OSL and post-IR IRSL signals from a c. 1 Ma sequence of aeolian and lacustrine deposits from the Nihewan Basin (northern China)

    DEFF Research Database (Denmark)

    Liu, Jinfeng; Murray, Andrew Sean; Buylaert, Jan-Pieter

    2016-01-01

    We tested the suitability of the fine-grained quartz (4–11 μm) Optical Stimulated Luminescence (OSL) and thermally-transferred OSL (TT-OSL), and the fine-grained polymineral (4–11 μm) post-infrared IRSL (post-IR IRSL or pIRIR) signals for dating samples from aeolian-lacustrine deposits from...... accurate ones; nevertheless, these ages provide the first long series absolute chronology for study of local palaeolithic and geomorphic evolution history aside from the  magnetostratigraphical results available before this research....

  3. An environmental BeO-OSL dosimeter for emergency response

    International Nuclear Information System (INIS)

    Woda, Clemens; Kaiser, Jan Christian; Urso, Laura; Greiter, Matthias

    2012-01-01

    A conceptual design is presented to use measurements of localized absorbed dose in inner cities for production of high resolution maps of the radioactive contamination following a nuclear emergency or radiological attack. The doses are derived from luminescent detectors pre-fixed at places of high importance (e.g. public squares). For such an environmental dosimeter, BeO is used, which can be read out using optically stimulated luminescence (OSL). A suitable casing of black Perspex has been developed to give a sufficiently accurate estimate of the air kerma value at the detector position. The dosimeter is characterized according to light tightness, dose response and angular photon energy dependence. A short overview of the approach for map production is also given. - Highlights: ► An inexpensive, environmentally stable BeO based OSL dosimeter has been developed for emergency response. ► The detector enables fast readouts and shows highly favorable dosimetric properties. ► A conceptual design is described to produce maps of radioactive contamination from localized dose measurements in urban areas.

  4. Application of pulsed OSL to polymineral fine-grained samples

    International Nuclear Information System (INIS)

    Feathers, James K.; Casson, M. Aksel; Schmidt, Amanda Henck; Chithambo, Makaiko L.

    2012-01-01

    Pulsed OSL is applied to nine fine-grained sediment samples from Sichuan province, China, using stimulating pulses of 10 μs on and 240 μs off, with an infrared exposure prior to each OSL measurement. Comparison of fading rates between pulsed and non-pulsed signals, the latter also obtained with a preceding IR exposure, shows that fading is significant for mainly the non-pulsed signals. Presence of a pulsed IRSL and the magnitudes of b-value to correct for lower alpha efficiency suggest that pulsing does not fully remove a significant feldspar signal, only a fading component. Comparison with ages of quartz extracts shows that pulsed OSL ages are consistent, while CW-OSL ages are slightly older and CW-IRSL ages are much older. The older ages suggest a less well-bleached feldspar component.

  5. TL and OSL studies on undoped diamond films grown by hot filament chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Soni, Anuj, E-mail: anujsoni.phy@gmail.com [Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Choudhary, R.K. [Materials Processing Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Polymeris, G.S. [Ankara University, Institute of Nuclear Sciences (Turkey); Mishra, D.R. [Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Mishra, P. [Materials Processing Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Kulkarni, M.S. [Radiation Safety Systems Division, Bhabha Atomic Research Center, Mumbai 400 085 (India)

    2016-09-15

    In this work, approximately 0.5 µm thick diamond films were grown on a silicon substrate by hot filament chemical vapour deposition (HFCVD) method in a gas mixture of hydrogen and methane. The batch to batch reproducibility of the sample using this technique was found to be very good. The obtained film was characterized by micro laser Raman spectroscopy (MLRS), grazing incidence X-ray diffractometry (GIXRD), scanning electron microscopy (SEM) and atomic force miscroscopy (AFM) techniques. MLRS and GIXRD results confirmed the formation of diamond whereas SEM and AFM analyses indicated uniform morphology of the film with an average grain size of 200 nm. The deposited film was studied for ionizing radiation dosimetry applications using the thermoluminescence (TL) and optically stimulated luminescence (OSL) techniques after irradiating the film by a calibrated 5 mCi, {sup 90}Sr/{sup 90}Y beta source. In the TL measurement, for a heating rate of 4 K/s, broad glow curve was obtained which was deconvoluted into seven TL peaks. The integrated TL counts were found to vary linearly with increasing the radiation dose up to 10 kGy. The characteristic TL output seen in the temperature range 200–300 °C, may be considered good for thermal stability of the film and it could also avoid TL fading during storage and non-interference of any black body radiation during the measurement. However, in comparison to TL output, the OSL response for 470 nm LED stimulation was found to be lesser. The CW–OSL decay curve has shown two components contributing to the OSL signal, having photoionization cross-section 1.5×10{sup −18} and 5.2×10{sup −19} cm{sup 2} respectively. The studies have revealed the possibility of using diamond film for high dose radiation dosimetry with TL/OSL method.

  6. Two-dimensional chronostratigraphic modelling of OSL ages from recent beach-ridge deposits, SE Australia

    DEFF Research Database (Denmark)

    Tamura, Toru; Cunningham, Alastair C.; Oliver, Thomas S.N.

    2018-01-01

    Optically-stimulated luminesecne (OSL) dating, in concert with two-dimensional ground-penetrating radar (GPR) profiling, has contributed to significant advances in our understanding of beach-ridge systems and other sedimentary landforms in various settings. For recent beach-ridges, the good OSL...... samples may be larger than the difference in sample ages. Age inversions can be avoided, however, if the stratigraphic constraints are included in the age estimation process. Here, we create a custom Bayesian chronological model for a recent (..., for direct comparison with a GPR profile. The model includes a full ‘burial-dose model’ for each sample and a dose rate term with the modelled ages constrained by the vertical and shore-normal sample order. The modelled ages are visualized by plotting isochrones on the beach-ridge cross section...

  7. Surface exposure dating of non-terrestrial bodies using optically stimulated luminescence: A new method

    DEFF Research Database (Denmark)

    Sohbati, Reza; Jain, Mayank; Murray, Andrew

    2012-01-01

    We propose a new method for in situ surface exposure dating of non-terrestrial geomorphological features using optically stimulated luminescence (OSL); our approach is based on the progressive emptying of trapped charge with exposure to light at depth into a mineral surface. A complete model of t...... charge population. The potential dating applications for (a) include dust accumulation, volcanic rocks and impact-related sediments, and for (b) fault scarps, rock-falls, landslides and ice-scoured bedrock. Using assumptions based on terrestrial observations we expect that this approach...

  8. The fast ratio: A rapid measure for testing the dominance of the fast component in the initial OSL signal from quartz

    International Nuclear Information System (INIS)

    Durcan, Julie A.; Duller, Geoff A.T.

    2011-01-01

    The signal from the fast component is usually considered preferable for quartz optically stimulated luminescence (OSL) dating, however its presence in a continuous wave (CW) OSL signal is often assumed, rather than verified. This paper presents an objective measure (termed the fast ratio) for testing the dominance of the fast component in the initial part of a quartz OSL signal. The ratio is based upon the photo ionisation cross-sections of the fast and medium components and the power of the measurement equipment used to record the OSL signal, and it compares parts of the OSL signal selected to represent the fast and medium components. The ability of the fast ratio to distinguish between samples whose CW-OSL signal is dominated by the fast and non-fast components is demonstrated by comparing the fast ratio with the contribution of the fast component calculated from curve deconvolution of measured OSL signals and from simulated data. The ratio offers a rapid method for screening a large number of OSL signals obtained for individual equivalent dose estimates, it can be calculated and applied as easily as other routine screening methods, and is transferrable between different aliquots, samples and measurement equipment. - Highlights: → Fast ratio is a measure which tests dominance of fast component in quartz OSL signals. → A fast ratio above 20 implies a CW-OSL signal is dominated by fast component. → Fast ratio can be easily and rapidly applied to a large number of OSL signals. → Uses include signal comparison, data screening, identify need for further analysis.

  9. Optically stimulated luminescence of MgB{sub 4}O{sub 7}:Ce,Li for gamma and neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Yukihara, E.G.; Doull, B.A.; Gustafson, T. [Physics Department, Oklahoma State University, Stillwater, OK 74078 (United States); Oliveira, L.C. [Physics Department, Oklahoma State University, Stillwater, OK 74078 (United States); Departamento de Física, FFCLRP-Universidade de São Paulo, 14040-901 Ribeirão Preto-SP (Brazil); Kurt, K. [Physics Department, Oklahoma State University, Stillwater, OK 74078 (United States); Mersin University Science and Letter Faculty Physics Department 33343 Mersin (Turkey); Milliken, E.D. [Physics Department, Oklahoma State University, Stillwater, OK 74078 (United States); R& D Pigments, Ferro Corporation, 251 W. Wylie Ave, Washington, PA 15301 (United States)

    2017-03-15

    The objective of this work was to develop a new optically stimulated luminescence (OSL) material for dosimetry applications that is tissue equivalent and has high sensitivity to ionizing radiation, fast luminescence lifetime, and intrinsic neutron sensitivity. To achieve this combination of properties, we started with a host material with low effective atomic number, MgB{sub 4}O{sub 7} (Z{sub eff}=8.2){sub ,} with an appropriate dopant characterized by short luminescence lifetime (Ce{sup 3+}). The samples were synthesized using Solution Combustion Synthesis with excess boric acid to achieve the correct crystallographic phase and Li co-doping to enhance its sensitivity. We investigated the thermoluminescence (TL) and OSL properties as a function of annealing temperature, radiation dose, dopant concentration, and time elapsed after irradiation (i.e., signal fading). We also applied a step-annealing procedure to investigate the depth of the trapping centers associated with the OSL signal. The samples obtained are characterized by a dominant TL peak at ~210 °C with intensity comparable to LiF:Mg,Ti. The OSL intensity is ~50% of that from Al{sub 2}O{sub 3}:C when using Hoya U-340 filters and shows no saturation up to almost 1 kGy. The OSL signal seems to originate from trapping center with stability > 150 °C, which means that the OSL fading is expected to be small. After the first day, in which fading associated with shallow traps is observed, fading of the total OSL signal was <4% within 6 days. The possibility of enhancing the neutron sensitivity was also demonstrated by synthesizing the material with enriched {sup 10}B. Although further development and characterization of the material may be needed, this work demonstrates that this host/dopant combination can be a viable alternative in OSL dosimetry, particularly for 2D dose mapping and neutron dosimetry applications.

  10. Photo-, thermo- and optically stimulated luminescence of monoclinic zirconia

    Energy Technology Data Exchange (ETDEWEB)

    Kiisk, Valter, E-mail: valter.kiisk@ut.ee [Institute of Physics, University of Tartu, Ravila 14c, 50411 Tartu (Estonia); Puust, Laurits; Utt, Kathriin; Maaroos, Aarne; Mändar, Hugo [Institute of Physics, University of Tartu, Ravila 14c, 50411 Tartu (Estonia); Viviani, Erica; Piccinelli, Fabio [Department of Biotechnology, University of Verona, Strada Le Grazie 15, 37134 Verona (Italy); Saar, Rando; Joost, Urmas; Sildos, Ilmo [Institute of Physics, University of Tartu, Ravila 14c, 50411 Tartu (Estonia)

    2016-06-15

    We carried out a careful photoluminescence (PL) and thermoluminescence (TL) characterization of nominally pure monoclinic ZrO{sub 2} nanopowders subject to oxidative vs reductive annealing (up to 1450 °C). The two kinds of studied zirconia (sol-gel-prepared vs commercial powder) exhibited virtually identical 490 nm PL emission band and 280 nm PL excitation band with slight, but clearly detectable variations in the spectral shape. The TL glow peaks, recorded over the temperature range −100 to 300 °C, showed an interplay depending on the type and treatment of sample. There is a strong evidence that the −35 and 205 °C glow peaks are due to oxygen vacancies whereas the 5 °C glow peak may relate to oxygen interstitials and the 110 °C glow peak to surface defects. Although a number of distinct glow peaks emerge, the material still seems to contain a quasi-continuous distribution of trap depths. In comparison to TL, we also demonstrate effective optically stimulated luminescence (OSL) from this polymorph of ZrO{sub 2} under red and NIR illumination at ~1 W/cm{sup 2}. All traps responsible for the principal TL peaks were also found to be OSL-active, which widens the applied importance of the material.

  11. OSL and TL retrospective dosimetry with a fluorapatite glass-ceramic used for dental restorations

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Judas, Libor; Sukupova, Lucie

    2013-01-01

    Optically Stimulated Luminescence (OSL) and Thermoluminescence (TL) properties of a fluorapatite glass-ceramic have been investigated, with a view to developing a dose assessment technique for medical triage following unplanned exposures of individuals to ionizing radiation. The ceramic is an innovative material used in dental prostheses and restorations. It is strongly sensitive to radiation and the intensity of both the OSL and TL signals are proportional to the absorbed radiation dose. We focused on the optimization of the measuring procedure and investigated characteristics such as reproducibility, fading, minimum detectable dose (MDD), dose response and photon energy response of TL and OSL signals. The dental ceramic exhibited very good reproducibility (<5% at 2σ level) when measured and a linear dose response for a wide range of doses (50 mGy–20 Gy). The MDD values for the samples investigated were ∼5 mGy. The material is not tissue equivalent and the OSL and TL signals are strongly dependent on incident photon energy. Both the luminescence signals exhibited significant fading during the first few hours after irradiation. Its rate was dependent on the parameters of measurement. The results indicate that the material can be used for the purposes of accident dosimetry, however, the fading and photon energy response have to be properly corrected for a reliable dose assessment. - Highlights: ► A dental ceramic was considered as a retrospective and accident dosimeter. ► Dosimetry application was investigated using OSL and TL. ► TL and OSL signals are proportional to absorbed radiation dose. ► Accuracy is dependent on correction of fading and photon energy response

  12. Thermal activation of OSL as a geothermometer for quartz grain heating during fault movements

    International Nuclear Information System (INIS)

    Rink, W.J.; Toyoda, S.; Rees-Jones, J.; Schwarcz, H.P.

    1999-01-01

    In discussions of ESR dating of fault movements, there has been much debate whether zeroing of ESR signals is a mechanical shearing effect or caused by frictional heating. The OSL (optically stimulated luminescence) sensitivity of quartz is known to increase after heating. This thermal activation of dose response of the OSL in quartz should be useful as a geothermometer to test whether quartz particles in fault gouge had been heated. We tested the OSL sensitivities of quartz from fault gouge, and from a control (quartz grains from sandstone) and were able to show heat-induced enhancement of OSL sensitivity to a test dose. We observed that relative enhancement of OSL dose response (ratio of heated to unheated single aliquots) is significantly less for the finest grains (45-75 and 100-150 μm) compared with coarser grains (150-250 μm). These data are consistent with a model of zeroing of the quartz grains during faulting, by frictional heating localized to the grain boundaries, which would be expected to affect smaller grains more than large ones. This argues against a zeroing model in which the entire fault gouge is heated by friction. Higher laboratory preheating of sandstone quartz reduces between-aliquot variability of OSL dose response in the unheated grains to nearly zero. Unheated coarsest fault gouge grains displayed virtually no among-aliquot variability, whereas fine grains showed much larger between-aliquot variability; as with the quartz sand, variability dropped to near zero after laboratory heating, suggesting that fine grains in fault gouge have experienced a wide range of natural thermal histories during faulting. This may present a problem for ESR dating of fault gouge using the plateau method

  13. Response of optically stimulated luminescence dosimeters subjected to X-rays in diagnostic energy range

    International Nuclear Information System (INIS)

    Musa, Y; Hashim, S; Karim, M K A; Ang, W C; Salehhon, N; Bakar, K A

    2017-01-01

    The use of optically stimulated luminescence (OSL) for dosimetry applications has recently increased considerably due to availability of commercial OSL dosimeters (nanoDots) for clinical use. The OSL dosimeter has a great potential to be used in clinical dosimetry because of its prevailing advantages in both handling and application. However, utilising nanoDot OSLDs for dose measurement in diagnostic radiology can only be guaranteed when the performance and characteristics of the dosimeters are apposite. In the present work, we examined the response of commercially available nanoDot OSLD (Al 2 O 3 :C) subjected to X-rays in general radiography. The nanoDots response with respect to reproducibility, dose linearity and signal depletion were analysed using microStar reader (Landauer, Inc., Glenwood, IL). Irradiations were performed free-in-air using 70, 80 and 120 kV tube voltages and tube currents ranging from 10 – 100 mAs. The results showed that the nanoDots exhibit good linearity and reproducibility when subjected to diagnostic X-rays, with coefficient of variations (CV) ranging between 2.3% to 3.5% representing a good reproducibility. The results also indicated average of 1% signal reduction per readout. Hence, the nanoDots showed a promising potential for dose measurement in general X-ray procedure. (paper)

  14. Quartz OSL dating of late Holocene beach ridges from the Magdalen Islands (Quebec, Canada)

    DEFF Research Database (Denmark)

    Remillard, A.M.; Buylaert, Jan-Pieter; Murray, Andrew

    2015-01-01

    Quartz optically stimulated luminescence (OSL) dating has been applied to sandy beach ridge systems from the Magdalen Islands in the center of the Gulf of St. Lawrence (Quebec, Canada) to provide the first chronological framework for these features. Nineteen beach ridges (22 samples) from four......). The OSL ages indicate that the ridges were built between 2.6 ± 0.2 ka and 0.40 ± 0.10 ka, i.e. during a period of sea level rise. This rise eroded adjacent sandstone cliffs, which contributed a significant sediment supply to the littoral drift and beaches. Some low-lying coasts in the archipelago...... great potential in this area, and is an appropriate method for establishing precise chronologies for coastal sediments in this region of the Gulf of St. Lawrence. © 2015 Elsevier B.V. All rights reserved....

  15. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon

    International Nuclear Information System (INIS)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M.; Castaneda, B.; Goncalves, J.A.N.; Sandonato, G.M.; Cruz Z, E.; Preciado F, S.; Cruz V, C.; Brown, F.; Schreck, M.

    2004-01-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  16. Luminescence dating of Pleistocene alluvial sediments affected by the Alhama de Murcia fault (eastern Betics, Spain) – a comparison between OSL, IRSL and post-IRIRSL ages

    DEFF Research Database (Denmark)

    Sohbati, Reza; Murray, Andrew S.; Buylaert, Jan-Pieter

    2012-01-01

    The ages of nine alluvial units, identified by the integration of data obtained from five trenches at the southern termination of the Alhama de Murcia Fault (AMF) (eastern Betics, Spain), are constrained using luminescence dating based on the Optically Stimulated Luminescence (OSL) from quartz...

  17. Thyroid dose measurement in patients undergoing to digital orthopantomography using optical stimulation dosimeters

    International Nuclear Information System (INIS)

    Gutierrez M, J. G.; Lopez V, A.; Rivera M, T.; Avalos P, L. Y.

    2016-10-01

    In this paper we present the study of the thyroid equivalent dose in 300 patients undergoing to digital orthopantomography for dental treatment purposes using optical stimulation dosimeters (OSL) as in-vivo dosimeters, in order to verify if this is within acceptable parameters to prevent stochastic risks and to evaluate the possible risks caused by the technique used for this type of study (66 kv, 5 m A, 14.1 s). Three OSL dosimeters were used per patient, which were placed by the physician on the skin above the thyroid gland (using anatomical references and palpation); the information of the patients was divided by neck size and sex, finding a slight increase in the equivalent dose for female and small size patient, this combination being the group that was submitted to a higher dose. The results obtained were compared with similar studies performed on anthropomorphic mannequins with TLD dosimeters obtaining lower results. The equivalent dose found even though is below the threshold stochastic damage must be motorized for radiological protection and registration purposes. (Author)

  18. OSL signal of IC chips from mobile phones for dose assessment in accidental dosimetry

    International Nuclear Information System (INIS)

    Mrozik, A.; Marczewska, B.; Bilski, P.; Książek, M.

    2017-01-01

    The rapid assessment of the radiation dose is very important for the prediction of biological effects after unintended exposition. The materials for use as dosimeters in accidental dosimetry should be everyday objects which are usually placed near the human body, for example mobile phones. IC (Integrated Circuit) chip is one of several electronic components of mobile phones which give a luminescent signal. The measurements of samples from different mobile phones and smartphones were conducted by optically stimulated luminescence (OSL) and thermoluminescence (TL) methods. The OSL measurement was performed in two ways: with readouts at room temperature and at 100 °C. This work is focused on determination of OSL dose response of IC chips, minimum detectable dose (MDD), OSL signal stability in the time after the exposition, its repeatability and sensitivity to light. Several tests of the assessment of unknown doses were also conducted. The readouts at 100 °C indicate the reducing of the fading of OSL signal in the first hours after irradiation in comparison with room temperature readouts. The obtained results showed relatively good dosimetric properties of IC chips: their high sensitivity to the ionizing radiation, linear dose response up to 10 Gy and a good reproducibility of OSL signal which can allow the dose recovery of doses less than 2 Gy in 14 days after an incident with the accuracy better than 25%. The fading is a drawback of IC chips and the fading factor should be considered when calculating the dose. - Highlights: • IC chips from smartphones demonstrated high potential for accidental dosimetry. • Minimum detectable dose was estimated as a value of 50 mGy. • Samples showed linear dose response for the dose range from 0.05 Gy up to 10 Gy.

  19. Plasmon-enhanced optically stimulated luminescence

    International Nuclear Information System (INIS)

    Guidelli, E. J.; Baffa, O.; Ramos, A. P.

    2015-10-01

    Full text: Optically Stimulated Luminescence dosimeters (OSLD) have been largely used for personal, medical, and industrial radiation dosimetry. Developing highly sensitive and small-sized radiation detectors and dosimeters is essential for improving spatial resolution and consequently diagnosis quality and treatment efficacy in the case of applications in radiodiagnosis and radiation therapy, for instance. Conventional methods to improve the OSLD sensitivity consist of doping and co-doping the host materials with atoms of other elements, thereby increasing the amount of trapping and/or luminescent centers. Our group is researching on the use of the plasmon properties of noble metal nanoparticles to increase OSL intensity. Upon incidence of a light beam with appropriate resonant wavelengths, the oscillation of the free electrons at the nanoparticle surface originates the Localized Surface Plasmons (LSP) and the consequent plasmon resonance band. The interaction between the LSP and the surrounding luminescent material leads to new optical properties largely employed for enhancing several luminescent processes. Here we will show our results regarding the use of LSP to increase OSLD sensitivity. The interaction between the traps/luminescent centers and the plasmons depends on the distance between them, on the plasmon resonance band intensity and position, as well as on the surrounding medium. Therefore, the plasmon-enhanced luminescence is a promising tool to develop more sensitive and miniaturized OSLD. (Author)

  20. Plasmon-enhanced optically stimulated luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Guidelli, E. J.; Baffa, O. [Universidade de Sao Paulo, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Departamento de Fisica, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, Sao Paulo (Brazil); Ramos, A. P., E-mail: ederguidelli@gmail.com [Universidade de Sao Paulo, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Departamento de Quimica, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, Sao Paulo (Brazil)

    2015-10-15

    Full text: Optically Stimulated Luminescence dosimeters (OSLD) have been largely used for personal, medical, and industrial radiation dosimetry. Developing highly sensitive and small-sized radiation detectors and dosimeters is essential for improving spatial resolution and consequently diagnosis quality and treatment efficacy in the case of applications in radiodiagnosis and radiation therapy, for instance. Conventional methods to improve the OSLD sensitivity consist of doping and co-doping the host materials with atoms of other elements, thereby increasing the amount of trapping and/or luminescent centers. Our group is researching on the use of the plasmon properties of noble metal nanoparticles to increase OSL intensity. Upon incidence of a light beam with appropriate resonant wavelengths, the oscillation of the free electrons at the nanoparticle surface originates the Localized Surface Plasmons (LSP) and the consequent plasmon resonance band. The interaction between the LSP and the surrounding luminescent material leads to new optical properties largely employed for enhancing several luminescent processes. Here we will show our results regarding the use of LSP to increase OSLD sensitivity. The interaction between the traps/luminescent centers and the plasmons depends on the distance between them, on the plasmon resonance band intensity and position, as well as on the surrounding medium. Therefore, the plasmon-enhanced luminescence is a promising tool to develop more sensitive and miniaturized OSLD. (Author)

  1. A compact design for monochromatic OSL measurements in the wavelength range 380-1020 NM

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Poolton, N.R.J.; Willumsen, F.

    1994-01-01

    automated Riso TL/OSL dating apparatus, thus allowing for either routine scanning or more detailed thermo-optical investigations. The high throughput efficiency of the unit means that the existing 75 W tungsten-halogen lamp can be directly used for such measurements on both quartz and feldspar samples......The development and performance of a compact module is described that allows for the monochromatic illumination of samples in the wavelength range 380-1020 nm, enabling the measurement of energy-resolved optically stimulated luminescence. The unit is designed to couple directly to the existing....... The design allows for rapid spectral scanning with a choice of resolution of anywhere between 10 and 80 nm: stray light levels are less than 0.01%. The unit can equally be used for recording wavelength-resolved emission spectra, whether photo-excited or thermally stimulated; the capabilities of the system...

  2. Online fibre optic OSL in vivo dosimetry for quality assurance of external beam radiation therapy treatments: The ANR-TECSAN Codofer Project

    International Nuclear Information System (INIS)

    Magne, S.; Ferdinand, P.; De Carlan, L.; Bridier, A.; Isambert, A.; Hugon, R.; Guillon, J.

    2010-01-01

    The Codofer Project (2007-2009), led under the ANR-TECSAN Call, was coordinated by CEA LIST, in partnership with IGR and the Fimel company. The aim of the project was to design and test both metrologically and in clinical conditions OSL optical fiber sensors dedicated to in vivo dosimetry during external beam radiation therapy treatment with high-energy electrons. This study, combined with the results of clinical tests obtained within the European Project Maestro, has demonstrated the advantages of OSL/FO dosimetry for providing quality assurance of treatments. However, the French market for dosimetry has greatly changed as a result of the rules decreed by the French government in 2007. The OSL/FO product is now targeted for other treatment modalities lacking suitable dosimeters (ANR-INTRADOSE Project [2009-2011]). (authors)

  3. Study of TL and optically stimulated luminescence of K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu nanophosphor for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Mandlik, Nandkumar [Department of Physics, University of Pune, Pune 411007 (India); Department of Physics, Ferguson College, Pune 411004 (India); Sahare, P.D. [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Kulkarni, M.S. [Radiological Physics and Advisory Division, BARC, Mumbai 400085, Maharashtra (India); Bhatt, B.C. [Radiation Safety Systems Division, BARC, Mumbai 400085, Maharashtra (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune 411007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411007 (India)

    2014-02-15

    Nanocrytstalline K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu phosphor was synthesized by the chemical co-precipitation method and annealed at different temperatures (400–900 °C) for 2 h. The XRD spectrum shows the cubic structure with crystallite size ∼20 nm. The same was also confirmed from the TEM image which shows the formation of nanorods having diameter ∼20 nm and length of ∼200 nm. They are found to be quite uniform in shapes and sizes. These samples were irradiated with gamma radiation for the doses varying from 0.01 Gy to 10 kGy and their thermoluminescence (TL) characteristics and continuous wave optically stimulated luminescence (CW-OSL) have been studied. The sample annealed at 700 °C was found to be most sensitive than others. The glow curves of the nanophosphor show a major peak at around 175 °C and other two peaks of low intensity at around 85 °C and 305 °C. The traps responsible for the three thermoluminescence peaks in K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu are also found to be sensitive to the OSL. The qualitative correlation between TL peaks and CW-OSL response is established. The TL response of the sample annealed at 700 °C for 2 h and irradiated with different gamma doses shows a linear behavior from 0.01 up to 300 Gy and become sublinear in the range of 300 Gy–1 kGy before it saturates with further increase in the dose, while, the OSL response of the same sample shows linearity up to 1 kGy. Simple glow curve structure, easy method of synthesis, and linear dose response make the nanocrystalline phosphor a good candidate for radiation dosimetry, especially for the estimation of high doses of gamma rays where the microcrystalline phosphors generally saturate. -- Highlights: • Nanocrytstalline K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu phosphor was synthesized by the chemical co-precipitation method. • Thermoluminescence (TL) and continuous wave optically stimulated luminescence (CW-OSL) characteristics have been studied. • The TL glow

  4. Optically stimulated luminescence in retrospective dosimetry

    International Nuclear Information System (INIS)

    Boetter-Jensen, L.; Murray, A.S.

    2002-01-01

    Since the beginning of the 1990s the exploration of optically stimulated luminescence in retrospective accident dosimetry has driven an intensive investigation and development programme at Ris deg. into measurement facilities and techniques. This paper reviews some of the outcomes of this programme, including the evaluation of the single-aliquot regenerative-dose measurement protocol with brick quartz and the determination of dose-depth profiles in building materials as a guide to determining the mean energy of the incident radiation. Investigations into heated materials are most advanced, and a lower detection limit for quartz extracted from Chernobyl bricks was determined to be <10 mGy. The first results from the measurement of doses in unheated building materials such as mortar and concrete are also discussed. Both small-aliquot and single-grain techniques have been used to assess accident doses in these cement based building materials more commonly found in workplaces. Finally some results of a preliminary investigation of the OSL properties of household chemicals are discussed with reference to their potential as accident dosemeters. (author)

  5. Towards dating Quaternary sediments using the quartz Violet Stimulated Luminescence (VSL) signal

    DEFF Research Database (Denmark)

    Ankjærgaard, C.; Jain, Mayank; Wallinga, J.

    2013-01-01

    Quaternary sediments using the violet (402 nm) stimulated luminescence (VSL) signal of quartz.We develop and test a new post-blue VSL single aliquot regenerative dose dating protocol, and demonstrate that the VSL signal originates from a deep trap at about 1.9 eV with a thermal lifetime of 1011 years at 10......Quartz optically stimulated luminescence (OSL) dating is widely used to determine the time of deposition and burial of Late Quaternary sediments. Application of the method is usually limited to the past 150,000 years due to early saturation of the OSL signal. Here we explore the potential to date...

  6. Commissioning optically stimulated luminescence in vivo dosimeters for fast neutron therapy

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lori A., E-mail: layoung@uw.edu; Sandison, George [Department of Radiation Oncology, University of Washington, Seattle, Washington 98115 (United States); Yang, Fei [Sylvester comprehensive Cancer Center, University of Miami, Miami, Florida 33124 (United States); Woodworth, Davis [Department of Physics, University of Reno, Reno, Nevada 89557 (United States); McCormick, Zephyr [Department of Physics, University of California, Santa Barbara, California 93106 (United States)

    2016-01-15

    Purpose: Clinical in vivo dosimeters intended for use with photon and electron therapies have not been utilized for fast neutron therapy because they are highly susceptible to neutron damage. The objective of this work was to determine if a commercial optically stimulated luminescence (OSL) in vivo dosimetry system could be adapted for use in fast neutron therapy. Methods: A 50.5 MeV fast neutron beam generated by a clinical neutron therapy cyclotron was used to irradiate carbon doped aluminum oxide (Al{sub 2}O{sub 3}:C) optically simulated luminescence dosimeters (OSLDs) in a solid water phantom under standard calibration conditions, 150 cm SAD, 1.7 cm depth, and 10.3 × 10.0 cm field size. OSLD fading and electron trap depletion studies were performed with the OSLDs irradiated with 20 and 50 cGy and monitored over a 24-h period to determine the optimal time for reading the dosimeters during calibration. Four OSLDs per group were calibrated over a clinical dose range of 0–150 cGy. Results: OSLD measurement uncertainties were lowered to within ±2%–3% of the expected dose by minimizing the effect of transient fading that occurs with neutron irradiation and maintaining individual calibration factors for each dosimeter. Dose dependent luminescence fading extended beyond the manufacturer’s recommended 10 min period for irradiation with photon or electron beams. To minimize OSL variances caused by inconsistent fading among dosimeters, the observed optimal time for reading the OSLDs postirradiation was between 30 and 90 min. No field size, wedge factor, or gantry angle dependencies were observed in the OSLDs irradiated by the studied fast neutron beam. Conclusions: Measurements demonstrated that uncertainties less than ±3% were attainable in OSLDs irradiated with fast neutrons under clinical conditions. Accuracy and precision comparable to clinical OSL measurements observed with photons can be achieved by maintaining individual OSLD calibration factors and

  7. Comparison of Cottonwood Dendrochronology and Optically Stimulated Luminescence Geochronometers Along a High Plains Meandering River, Powder River, Montana, USA

    Science.gov (United States)

    Hasse, T. R.; Schook, D. M.

    2017-12-01

    Geochronometers at centennial scales can aid our understanding of process rates in fluvial geomorphology. Plains cottonwood trees (Populus deltoides ssp. Monilifera) in the high plains of the United States are known to germinate on freshly created deposits such as point bars adjacent to rivers. As the trees mature they may be partially buried (up to a few meters) by additional flood deposits. Cottonwood age gives a minimum age estimate of the stratigraphic surface where the tree germinated and a maximum age estimate for overlying sediments, providing quantitative data on rates of river migration and sediment accumulation. Optically Stimulated Luminescence (OSL) of sand grains can be used to estimate the time since the sand grains were last exposed to sunlight, also giving a minimum age estimate of sediment burial. Both methods have disadvantages: Browsing, partial burial, and other damage to young cottonwoods can increase the time required for the tree to reach a height where it can be sampled with a tree corer, making the germination point a few years to a few decades older than the measured tree age; fluvial OSL samples can have inherited age (when the OSL age is older than the burial age) if the sediment was not completely bleached prior to burial. We collected OSL samples at 8 eroding banks of the Powder River Montana, and tree cores at breast height (±1.2 m) from cottonwood trees growing on the floodplain adjacent to the OSL sample locations. Using the Minimum Age Model (MAM) we found that OSL ages appear to be 500 to 1,000 years older than the adjacent cottonwood trees which range in age (at breast height) from 60 to 185 years. Three explanations for this apparent anomaly in ages are explored. Samples for OSL could be below a stratigraphic unconformity relative to the cottonwood germination elevation. Shallow samples for OSL could be affected by anthropogenic mixing of sediments due to plowing and leveling of hay fields. The OSL samples could have

  8. NaCl samples for optical luminescence dosimetry

    International Nuclear Information System (INIS)

    Catli, S.

    2005-01-01

    Optically stimulated luminescence (OSL) have been used broadly for luminescence dosimetry and dating. In many cases, it has been pointed out that the decay of the OSL do not generally behave according to a simple exponential function. In this study the Infra-red stimulated luminescence (IRSL) intensity from NaCl samples were experimentally measured. The decay curves for this sample were fitted to some functions and it is in good agreement with the function y = α + b exp(-cx). The IRSL decay curves from NaCl using different β-doses have been obtained and investigated their dose response

  9. Thermoluminescence and optically stimulated luminescence properties of Dy{sup 3+}-doped CaO–Al{sub 2}O{sub 3}–B{sub 2}O{sub 3}-based glasses

    Energy Technology Data Exchange (ETDEWEB)

    Yahaba, T., E-mail: takuma.yahaba.s1@dc.tohoku.ac.jp [Department of Applied Chemistry, Graduate School of Engineering, Tohoku University, 6-6-07 Aramaki Aza Aoba, Aoba-ku, Sendai 980-8579 (Japan); Fujimoto, Y. [Department of Applied Chemistry, Graduate School of Engineering, Tohoku University, 6-6-07 Aramaki Aza Aoba, Aoba-ku, Sendai 980-8579 (Japan); Yanagida, T. [Nara Institute of Science and Technology (NAIST), 8916-5 Takayama, Ikoma 630-0192 (Japan); Koshimizu, M.; Tanaka, H.; Saeki, K.; Asai, K. [Department of Applied Chemistry, Graduate School of Engineering, Tohoku University, 6-6-07 Aramaki Aza Aoba, Aoba-ku, Sendai 980-8579 (Japan)

    2017-02-01

    We developed Dy{sup 3+}-doped CaO–Al{sub 2}O{sub 3}–B{sub 2}O{sub 3} based glasses with Dy concentrations of 0.5, 1.0, and 2.0 mol% using a melt-quenching technique. The as-synthesized glasses were applicable as materials exhibiting thermoluminescence (TL) and optically stimulated luminescence (OSL). The optical and radiation response properties of the glasses were characterized. In the photoluminescence (PL) spectra, two emission bands due to the {sup 4}F{sub 9/2} → {sup 6}H{sub 15/2} and {sup 4}F{sub 9/2} → {sup 6}H{sub 13/2} transitions of Dy{sup 3+} were observed at 480 and 580 nm. In the OSL spectra, the emission band due to the {sup 4}F{sub 9/2} → {sup 6}H{sub 15/2} transition of Dy{sup 3+} was observed. Excellent TL and OSL responses were observed for dose ranges of 0.1–90 Gy. In addition, TL fading behavior was better than that of OSL in term of the long-time storage. These results indicate that the Dy{sup 3+}-doped CaO–Al{sub 2}O{sub 3}–B{sub 2}O{sub 3}-based glasses are applicable as TL materials.

  10. Optically stimulated luminescence sensitivity changes in quartz due to repeated use in single aliquot readout: Experiments and computer simulations

    DEFF Research Database (Denmark)

    McKeever, S.W.S.; Bøtter-Jensen, L.; Agersnap Larsen, N.

    1996-01-01

    believed to be occurring. The computer model used includes both shallow and deep ('hard-to-bleach') traps, OSL ('easy-to-bleach') traps, and radiative and non-radiative recombination centres. The model has previously been used successfully to account for sensitivity changes in quartz due to thermal......As part of a study to examine sensitivity changes in single aliquot techniques using optically stimulated luminescence (OSL) a series of experiments has been conducted with single aliquots of natural quartz, and the data compared with the results of computer simulations of the type of processes...... annealing. The simulations are able to reproduce qualitatively the main features of the experimental results including sensitivity changes as a function of reuse, and their dependence upon bleaching time and laboratory dose. The sensitivity changes are believed to be the result of a combination of shallow...

  11. Optical dating of potteries excavated from Pungnabtoseong earthen wall, Seoul

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Jin; Park, Mi Seon [Neosiskorea Co., Daejeon (Korea, Republic of); Lee, Sung Joon; Nah, Hye Rim; Hong, Hyung Woo [National Research Institute of Cultural Heritage, Daejeon (Korea, Republic of)

    2012-05-15

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) emitted from natural crystalline mineral, usually quartz, feldspar, and so on, are mainly used to evaluate the paleodose for the age determination of archaeological and geological sample and the equivalent dose for retrospective dosimetry. TL/OSL age can be calculated as the ratio of paleodose to total annual dose rate which is determined from surrounding soil. In this study, we chemically extracted the quartz samples from potteries excavated in Pungnabtoseong earthen wall and observed the TL/OSL characteristics for paleodose determination. With the converted annual dose rate from the concentration of radioactive isotopes in its surrounding soil, optical date was evaluated and finally illustrated for interpreting the construction stage of Pungnabtoseong

  12. Modelling the thermal quenching mechanism in quartz based on time-resolved optically stimulated luminescence

    International Nuclear Information System (INIS)

    Pagonis, V.; Ankjaergaard, C.; Murray, A.S.; Jain, M.; Chen, R.; Lawless, J.; Greilich, S.

    2010-01-01

    This paper presents a new numerical model for thermal quenching in quartz, based on the previously suggested Mott-Seitz mechanism. In the model electrons from a dosimetric trap are raised by optical or thermal stimulation into the conduction band, followed by an electronic transition from the conduction band into an excited state of the recombination center. Subsequently electrons in this excited state undergo either a direct radiative transition into a recombination center, or a competing thermally assisted non-radiative process into the ground state of the recombination center. As the temperature of the sample is increased, more electrons are removed from the excited state via the non-radiative pathway. This reduction in the number of available electrons leads to both a decrease of the intensity of the luminescence signal and to a simultaneous decrease of the luminescence lifetime. Several simulations are carried out of time-resolved optically stimulated luminescence (TR-OSL) experiments, in which the temperature dependence of luminescence lifetimes in quartz is studied as a function of the stimulation temperature. Good quantitative agreement is found between the simulation results and new experimental data obtained using a single-aliquot procedure on a sedimentary quartz sample.

  13. Optimizing detection filters for single-grain optical dating of quartz

    International Nuclear Information System (INIS)

    Ballarini, M.; Wallinga, J.; Duller, G.A.T.; Brouwer, J.C.; Bos, A.J.J.; Van Eijk, C.W.E.

    2005-01-01

    We investigate the use of different optical detection filters for single-grain optically stimulated luminescence (OSL) measurements of quartz samples with a Riso TL/OSL single-grain reader. We selected three filter combinations that considerably improve the light detection efficiency when compared with the 7.5 mm U340 filters that are routinely used. These are the UG1+BG4 filter combination, the 2 mm UG1 and the 2.5 mm U340 filters, which allow a greater transmission in the quartz emission band. This leads to two benefits: (1) more grains can be accepted for equivalent dose analysis, and (2) OSL responses on individual grains are determined with a greater precision. While these three alternative filter combinations perform equally well if compared to each other, we suggest the 2.5 mm thick Hoya U340 to be the filter of choice as it allows the use of blue-diode and IR-diode stimulation sources for bleaching purposes and feldspar detection

  14. PIXE multivariate statistics and OSL investigation for the classification and dating of archaeological pottery excavated at Tell Al-Rawda site, Syria

    Energy Technology Data Exchange (ETDEWEB)

    Bakraji, E.H., E-mail: cscientificl@aec.org.sy [Archaeometry Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P. O. Box 6091, Damascus (Syrian Arab Republic); Rihawy, M.S. [Archaeometry Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P. O. Box 6091, Damascus (Syrian Arab Republic); Castel, C. [CNRS – Maison de l’Orient et de la Méditerranée, Laboratoire “Archéorient”, CNRS/Université Lumière-Lyon 2 (France); Abboud, R. [Archaeometry Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P. O. Box 6091, Damascus (Syrian Arab Republic)

    2015-03-15

    Highlights: •PIXE and OSL methods were used to classify and date pottery from Tell Al-Rawda site. •Three groups were classified using PIXE, which suggest different sources of the clay. •OSL was used for dating the site and the date found was consistent with typology. -- Abstract: Particle Induced X-ray Emission (PIXE) technique has been utilised to study 48 Syrian ancient pottery fragments taken from excavations at Tell Al-Rawda site. Eighteen elements (Mg, Al, Si, P, S, K, Ca, Ti, Mn, Fe, Ni, Zn, As, Br, Rb, Sr, Y, and Pb) were determined. The elements concentrations have been processed using two multivariate statistical methods, to classify the pottery where one main group and other two small groups were defined. In addition, four samples from different places on the site were subjected to optically stimulated luminescence (OSL) dating. The average age obtained using a single aliquot regeneration (SAR) protocol was found to be 4350 ± 240 year.

  15. PIXE multivariate statistics and OSL investigation for the classification and dating of archaeological pottery excavated at Tell Al-Rawda site, Syria

    International Nuclear Information System (INIS)

    Bakraji, E.H.; Rihawy, M.S.; Castel, C.; Abboud, R.

    2015-01-01

    Highlights: •PIXE and OSL methods were used to classify and date pottery from Tell Al-Rawda site. •Three groups were classified using PIXE, which suggest different sources of the clay. •OSL was used for dating the site and the date found was consistent with typology. -- Abstract: Particle Induced X-ray Emission (PIXE) technique has been utilised to study 48 Syrian ancient pottery fragments taken from excavations at Tell Al-Rawda site. Eighteen elements (Mg, Al, Si, P, S, K, Ca, Ti, Mn, Fe, Ni, Zn, As, Br, Rb, Sr, Y, and Pb) were determined. The elements concentrations have been processed using two multivariate statistical methods, to classify the pottery where one main group and other two small groups were defined. In addition, four samples from different places on the site were subjected to optically stimulated luminescence (OSL) dating. The average age obtained using a single aliquot regeneration (SAR) protocol was found to be 4350 ± 240 year

  16. The effect of pre-dose on thermally and optically stimulated luminescence from α-Al2O3:C,Mg and α-Al2O3:C.

    Science.gov (United States)

    Kalita, J M; Chithambo, M L

    2018-06-15

    We report the effect of pre-dose on the thermoluminescence (TL) and optically stimulated luminescence (OSL) dose response of α-Al 2 O 3 :C,Mg and α-Al 2 O 3 :C. Before any luminescence measurement, the samples were irradiated with different doses, namely 100, 500 and 1000 Gy to populate the deep electron traps. This is the pre-dose. The results from TL and OSL studies are compared with results from samples used without any pre-measurement dose. The TL glow curves and OSL decay curves of α-Al 2 O 3 :C,Mg recorded after pre-doses of 100, 500 and 1000 Gy are identical to those from a sample used without any pre-dose. Further, the TL and OSL dose response of all α-Al 2 O 3 :C,Mg samples are similar regardless of pre-dose. In comparison, the TL glow curves and OSL decay curves of α-Al 2 O 3 :C are influenced by pre-dose. We conclude that the differences in the TL and OSL dose response of various pre-dosed samples of α-Al 2 O 3 :C are due to the concentration of charge in the deep traps. On the other hand, owing to the lower concentration of such deep traps in α-Al 2 O 3 :C,Mg, the TL or OSL dose responses are not affected by pre-dose in this material. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Quartz OSL Dating of the loess deposit in the eastern Tibetan Plateau and its environment implications since the Last Glaciation

    Science.gov (United States)

    Yang, S.; Cheng, T.; Liu, W.; Fang, X.

    2017-12-01

    Loess deposit is widespread in the Chuanxi Plateau, the eastern Tibetan Plateau, which is a critical archive for understanding the aeolian process, the evolution of the westerly and the environment changes on the Plateau. Previous studies have shown its aeolian origin, and mainly transported by wind from the western part of the Tibetan Plateau. However, the aeolian processes of the loess and its environment implications are not well understood mainly due to lack of detailed age controls. We carry out a combined quartz optically stimulated luminescence (OSL) dating and accelerator mass spectrometry radiocarbon dating (AMS 14-C) for the loess deposits in Garzê and Jinchuan. The results indicate that the quartz OSL dating can provide reliable age controls for the loess-paleosol sequences from the Chuanxi Plateau, showing the potential of OSL to date loess in the high altitude region. The results indicate that the OSL ages are in agreement with the observed stratigraphy in the field. The constructed OSL and AMS 14-C chronology of the Garzê loess reveals that the widespread loess in Ganzi Region deposited since the Last Glacial. The dust accumulation is rapid during marine isotope stage (MIS) 3 and 2, and a relative low accumulation rate in the Holocene, which may related with the desertification processes of the inner Tibetan Plateau.

  18. Modelling the optical bleaching of the thermoluminescence of K2YF5:Pr3+

    International Nuclear Information System (INIS)

    Marcazzó, J.; Santiago, M.; Khaidukov, N.; Caselli, E.

    2012-01-01

    Optical bleaching of the thermoluminescence (TL) curve of K 2 YF 5 :Pr 3+ has been observed after optically stimulated luminescence (OSL) readout of pre-irradiated crystals. The traps being responsible for the TL signal are not emptied completely by the optical stimulation. Furthermore, if the illumination time is increased a constant intensity level of the residual TL glow curve is eventually achieved. On the other hand, if the low temperature peak of the glow curve is thermally cleaned, no subsequent OSL is measured. This behavior has been successfully explained by assuming that part of the electrons in the trap being responsible for the low temperature glow peak of K 2 YF 5 :Pr 3+ recombine with holes via localized transitions during optical stimulation. During TL all trapped electrons recombine via delocalized transitions. Simulations have been carried out in order to demonstrate the feasibility of the model. - Highlights: ► The optical bleaching of the thermoluminescence of K2YF5:Pr 3+ has been studied. ► A model accounting for the optical bleaching has been put forward. ► Thermoluminescence occurs via delocalized transitions. ► Localized transitions occur during optical stimulation.

  19. Optically stimulated luminescence sensitivity changes in quartz due to repeated use in single aliquot readout: experiments and computer simulations

    International Nuclear Information System (INIS)

    McKeever, S.W.S.; Oklahoma State Univ., Stillwater, OK; Boetter-Jensen, L.; Agersnap Larsen, N.; Mejdahl, V.; Poolton, N.R.J.

    1996-01-01

    As part of a study to examine sensitivity changes in single aliquot techniques using optically stimulated luminescence (OSL) a series of experiments has been conducted with single aliquots of natural quartz, and the data compared with the results of computer simulations of the type of processes believed to be occurring. The computer model used includes both shallow and deep ('hard-to-bleach') traps, OSL ('easy-to-bleach') traps, and radiative and non-radiative recombination centres. The model has previously been used successfully to account for sensitivity changes in quartz due to thermal annealing. The simulations are able to reproduce qualitatively the main features of the experimental results including sensitivity changes as a function of re-use, and their dependence upon bleaching time and laboratory dose. The sensitivity changes are believed to be the result of a combination of shallow trap and deep trap effects. (author)

  20. Insect wings as retrospective/accidental/forensic dosimeters: An optically stimulated luminescence investigation

    International Nuclear Information System (INIS)

    Kazakis, Nikolaos A.; Tsetine, Anastasia Th.; Kitis, George; Tsirliganis, Nestor C.

    2016-01-01

    Estimation of the radiation released during nuclear accidents or radiological terrorist events is imperative for the prediction of health effects following such an exposure. In addition, in several cases there is a need to identify the prior presence of radioactive materials at buildings or sites (nuclear forensics). To this direction, several materials have been the research object of numerous studies the last decade in an attempt to identify potentially new retrospective/accidental/forensic dosimeters. However, the studies targeting biological materials are limited and their majority is mainly focused on the luminescence behavior of human biological material. Consequently, the use of such materials in retrospective dosimetry presumes the exposure of humans in the radiation field. The present work constitutes the first attempt to seek non-human biological materials, which can be found in nature in abundance or in/on other living organisms. To this end, the present work investigates the basic optically stimulated luminescence behavior of insect wings, which exhibit several advantages compared to other materials. Insects are ubiquitous, have a short life expectancy and exhibit a low decomposition rate after their death. Findings of the present study are encouraging towards the potential use of insects' wings at retrospective/accidental/forensic dosimetry, since they exhibit linear OSL response over a wide dose range and imperceptible loss of signal several days after their irradiation when they are kept in dark. On the other hand, the calculated lower detection limit is not low enough to allow their use as emergency dosimeters when individuals are exposed to non-lethal doses. In addition, wings exhibit strong optical fading when they are exposed to daylight and thus special care should be taken during the sampling procedure in order to use the wings as accidental/forensic dosimeters, by seeking (dead) insects in dark places, such as behind furniture, equipment or in

  1. Study of morphological and luminescent properties (TL and OSL) of ZnO nanocrystals synthetized by coprecipitation method

    Energy Technology Data Exchange (ETDEWEB)

    Soares, A.F., E-mail: alvarodefarias@hotmail.com; Tatumi, S.H., E-mail: sonia.tatumi@gmail.com; Mazzo, T.M.; Rocca, R.R.; Courrol, L.C.

    2017-06-15

    In this work, ZnO nanocrystalline phosphorus were synthesized using the method of coprecipitation, subsequently different heat treatments at 900 and 1000 °C for 2 h and 1000 °C for 4 h were performed. Afterward, Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) emissions were verified after exposure to β-radiation. Photoluminescence results showed UV and VIS emissions. Morphological studies with X-ray diffraction (XRD) and Scanning Electron Microscopy (SEM) confirmed the crystallinity of the samples, with their well-shaped wurtzite hexagonal structures in nanoscale. ZnO calcinated at 900 °C – 2 h emitted a broad TL peak located between the 362–372 °C; for ZnO calcinated at 1000 °C – 2 h, two intense peaks were observed at 144 and 308 °C, this TL emission curve was investigated with more details using Computerized Glow Curve Deconvolution and six individual TL peaks were obtained, for sample irradiated with 40.6 Gy, corroborating with the T{sub m}-T{sub stop} results. A study of Minimum Detectable Dose (MDD) was made and a dose of (492±40) μGy was determined. CW-OSL and LM-OSL analysis were made for ZnO calcinated at 1000 °C – 2 h, allowed to verify the behaviour, and the curve existing components (fast and medium, depending on dose). As well as the calculation of the Minimum Detectable Dose for CW-OSL. - Highlights: •ZnO nanocrystals were successfully produced by the method of coprecipitation. •Grains sizes by Scherrer Equation were between 26.9–40.6 nm, corroborating with SEM. •Study of the TL emission: Computerized Glow Curve Deconvolution (CGCD) and Tm-Tstop. •TL emission of ZnO calcinated supplied the minimum detectable dose of (492±40) μGy. •Study of CW-OSL and LM-OSL with CGCD. MDD for CW-OSL evaluation of ZnO calcinated.

  2. X-ray or UV-ray imaging sensor utilizing optically stimulated luminescence phenomenon in Eu-doped KCl phosphors

    International Nuclear Information System (INIS)

    Nanto, Hidehito; Murayama, Kazuhiko; Hirai, Yoshiaki; Taniguchi, Shin-ichi; Makamura, Shouichi; Takeuchi, Nozomu.

    1993-01-01

    An intense OSL with a peak at about 420 [nm] has been observed by stimulating an X-ray or UV-ray irradiated KCl: Eu crystal with F-band light whose wavelength is about 560 [um]. A possible excitation and emission mechanisms for the 420 [um] OSL peak X-ray or UV-ray irradiated sample is proposed. It is found that the OSL intensity is proportional to the X-ray absorbed dose or UV-ray irradiation dose. It is also found that X-ray or UV-ray irradiated KCl; Eu exhibited excellent fading characteristics. These results strongly suggest that the KCl: Eu is one of the most attractive candidates for two-dimensional X-ray or UV-ray imaging sensor utilizing the OSL phenomenon. (J.P.N.)

  3. A study on the development of personal radiation dosimetry system based on the pulsed optically stimulated luminescence of α-Al2O3:C

    International Nuclear Information System (INIS)

    Lee, Sang Yoon

    2000-02-01

    High quality radiation dosimetry is for workers who rely upon personal dosimeters to record the amount of radiation to which they are exposed. Radiation physicists have been exploring thermoluminescence dosimeter (TLD) for personal monitoring since the mid 1960s, although, widespread use has only occurred in the last 20 years as automated analytical systems and high quality TLD crystals became commercially available. nowadays, multiple TLD (thermoluminescence dosimeter) chips with appropriate physical filters are generally used for measurements of the personal dose equivalent quantities, H p (d). Though the TLD offers several advantages not possessed by radiological film, it does not offer the some type of advantages as films: re-analysis of an exposure situation is prohibited because the analysis process clears all of the useful dosimetric traps and a record of the luminescence intensity in the form of a glow curve is all that is available after analysis. In addition, the high heating temperatures restrict packaging methods and prevent competitively priced thin films of TLD crystal powders. Optically stimulated luminescence (OSL) technology avoids many engineering limitations imposed by the high heating temperatures used for TLD technology. OSL crystalline powders can be dispersed in various plastics unable to withstand the TLD heating regimen. With uniform dispersion in the plastic, mass-manufacturing techniques can produce large quantities of identically performing detectors. The first proposal conducted by Markey et al. for applications and potentials of α-AI 2 O 3 :C for OSL dosimetry opened a new era for this phosphor. Pulsed and continuous wave OSL studies carried out on α-AI 2 O 3 :C have shown that the material seems to be the most promising for routine application of OSL for dosimetric purposes. The main objective of this study is to develop a multi-area personal OSL dosimetry system using α-AI 2 O 3 :C by taking advantage of its optical properties and

  4. Optically stimulated luminescence dating of the Huanghe river terrace in Lanzhou basin

    International Nuclear Information System (INIS)

    Wang Ping; Yuan Daoyang; Liu Xinwang; Jiang Hanchao

    2007-01-01

    In this paper, profile observation and geologic strata structure analysis on the third level terrace at Fanjiaping on the south bank of the Huanghe River in the Lanzhou basin were reported, and systemically collected samples of fluvial sediments and the overlying diluvium and aeolian loess were analyzed by optically stimulated luminescence (OSL). The granulometric and magnetic susceptibility samples from the fine grain sedimentary layer at the middle of the profile were collected at a 2.5 cm interval. According to simplified multiple aliquot dating on fine grain quartz of 16 optically stimulated luminescence samples and electron spin resonance (ESR) dating of the underlying early fluvial layer, the following chronology results of the strata profile of the third terrace were obtained. The under- lying early fluvial layer is of gravels that belong to Fanjiaping formation in early and middle Pleistogene. The river-bed sedimentation of the Huanghe River started about 80,000 years ago. The accumulation of mainly proluvial sediments started about 70,000 years ago. And the continuous loess accumulation began about 55,000 years ago. The age of formation of the third terrace of Huanghe River was estimated at about 70,000 years, corresponding to the time between the last interglacial period and the last glacial period in the late Pleistocene. (authors)

  5. Synthesis and TL/OSL properties of a novel high-sensitive blue-emitting LiSrPO{sub 4}:Eu{sup 2+} phosphor for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Palan, C.B.; Koparkar, K.A.; Omanwar, S.K. [Sant Gadge Baba Amravati University, Department of Physics, Amravati (India); Bajaj, N.S. [Toshniwal Arts, Commerce and Science College, Sengoan, Hingoli District, MH (India); Soni, A. [Bhabha Atomic Research Centre, Radiological Physics and Advisory Division, Mumbai (India)

    2016-07-15

    In this study, a series of Eu{sup 2+}-doped LiSrPO{sub 4} phosphors were synthesized via solid-state method. The structural and morphological characterizations were done through X-ray diffraction and scanning electronic microscope. Additionally, the photoluminescence (PL), thermoluminescence (TL) and optically stimulated luminescence (OSL) behaviours of LiSrPO{sub 4}:Eu{sup 2+} phosphors were studied. The LiSrPO{sub 4}:Eu{sup 2+} phosphor shows OSL sensitivity about 8 times than that of α-Al{sub 2}O{sub 3}:C phosphor and 6 times than that of LiMgPO{sub 4}:Tb{sup 3+}, B phosphor. Moreover, TL sensitivity was about 15 times more as compared to α-Al{sub 2}O{sub 3}:C phosphor. The kinetic parameters of TL curve were calculated using peak shape method. In TL/OSL mode, dose-response was almost linear nature, in the range of measurement. The minimum detectable dose was found to be 25.18 μGy with 3σ of background. Also, reusability was also studies, which shows the phosphor can be reusable for 10 cycles with 0.1 % change in OSL output. (orig.)

  6. Dating recent floodplain sediments in the Hawkesbury-Nepean River system, eastern Australia using single-grain quartz OSL

    DEFF Research Database (Denmark)

    Sim, Anna K.; Thomsen, Kristina Jørkov; Murray, K.J.

    2014-01-01

    Two fluvial sediment cores taken from a floodplain of the Hawkesbury-Nepean River system in the Sydney region, eastern Australia are dated using Optically Stimulated Luminescence (OSL) to provide a reliable chronology essential for the management and planning of water resources. Nine charcoal 14C...... in an average apparent age overestimation of ~200 years, which is significant for these samples, but negligible for sediments older than a few thousand years. The intention is that the chronology obtained in this study will be used in conjunction with a proxy flood record, derived from floodplain sediments...

  7. Optical dating of dune ridges on Rømø

    DEFF Research Database (Denmark)

    Madsen, Anni Tindahl; Murray, A. S.; Andersen, Thorbjørn Joest

    2007-01-01

    The application of optically stimulated luminescence (OSL) to the dating of recent aeolian sand ridges on Rømø, an island off the southwest coast of Denmark, is tested. These sand ridges began to form approximately 300 years ago, and estimates of the ages are available from historical records....... Samples for OSL dating were taken ~0.5 m below the crests of four different dune ridges; at least five samples were recovered from each ridge to test the internal consistency of the ages. Additional samples were recovered from the low lying areas in the swales and from the scattered dune formations......-defined building phases separated by inactive periods and the first major ridge formed ~235 years ago. This study demonstrates that optical dating can be successfully applied to these young aeolian sand deposits, and we conclude that OSL dating is a powerful chronological tool in studies of coastal change....

  8. Extending the area of investigation of fine versus coarse quartz optical ages from the Lower Danube to the Carpathian Basin

    DEFF Research Database (Denmark)

    Timar-Gabor, Alida; Constantin, Daniela; Marković, S.B.

    2015-01-01

    mm) grains and coarse (63e90 mm) grains respectively. The current study aims at expanding these investigations, both by extending the area of study from the Lower Danube Basin to the Carpathian Basin and by applying time-resolved optically stimulated luminescence (TR-OSL) on quartz, in order to gain...... is observed for both continuous wave (CW-OSL) and pulsed OSL (POSL), where the dose response (up to 1000 Gy) is well described by a sum of two saturating exponential functions. TR-OSL measurements show one single, characteristic quartz lifetime for both natural as well as regenerative signals in the entire...

  9. OSL-SAR dating of sediments from Brazilian aeolian system: Dama Branca, Rio de Janeiro, morphodynamic study

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do; Watanabe, Shigueo, E-mail: lsatiro@usp.br, E-mail: lacifid@if.usp.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); DeWitt, Regina, E-mail: dewittr@ecu.edu [East Carolina University (ECU), Greenville, NC (United States)

    2017-07-01

    It has been reported that the formation and stabilization of coastal dune fields in Brazil have a dependence on the climate changes and Relative Sea Level (RSL) variations. A few topics regarding the morphodynamics of coastal aeolian systems in Brazil can be the RSL variations in the Holocene and weather conditions. In this work, a dune field known as 'Dama Branca', located in the town of Cabo Frio, Rio de Janeiro, has been studied to understand its formation and stabilization. Dating by trapped charge dating techniques as Optically Stimulated Luminescence (OSL) using the Single Aliquot Regenerative protocol (SAR), help to understand the formation and dynamics of aeolian systems in Brazil. Samples from a dune were collected from different heights and points for dating. The results obtained by OSL-SAR showed that ages decrease as the height from the dune base increase and older samples are found in deeper horizontal positions. The ages for the base of the studied dunes indicated that its stabilization occurred during the recess of the sea level. (author)

  10. OSL-SAR dating of sediments from Brazilian aeolian system: Dama Branca, Rio de Janeiro, morphodynamic study

    International Nuclear Information System (INIS)

    Carmo, Lucas S. do; Watanabe, Shigueo; DeWitt, Regina

    2017-01-01

    It has been reported that the formation and stabilization of coastal dune fields in Brazil have a dependence on the climate changes and Relative Sea Level (RSL) variations. A few topics regarding the morphodynamics of coastal aeolian systems in Brazil can be the RSL variations in the Holocene and weather conditions. In this work, a dune field known as 'Dama Branca', located in the town of Cabo Frio, Rio de Janeiro, has been studied to understand its formation and stabilization. Dating by trapped charge dating techniques as Optically Stimulated Luminescence (OSL) using the Single Aliquot Regenerative protocol (SAR), help to understand the formation and dynamics of aeolian systems in Brazil. Samples from a dune were collected from different heights and points for dating. The results obtained by OSL-SAR showed that ages decrease as the height from the dune base increase and older samples are found in deeper horizontal positions. The ages for the base of the studied dunes indicated that its stabilization occurred during the recess of the sea level. (author)

  11. Estimation of identification limit for a small-type OSL dosimeter on the medical images by measurement of X-ray spectra

    OpenAIRE

    Takegami, Kazuki ; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi ; Maehata, Itsumi ; Kanazawa, Yuki ; Okazaki, Tohru ; Hashizume, Takuya ; Kobayashi, Ikuo 

    2016-01-01

    Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1–20 cm), and a CdTe X...

  12. Estimation of identification limit for a small-type OSL dosimeter on the medical images by measurement of X-ray spectra.

    Science.gov (United States)

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-07-01

    Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1-20 cm), and a CdTe X-ray spectrometer assuming one pixel of the X-ray imaging detector. Then, with the following two experimental settings, corresponding X-ray spectra were measured with 40-120 kVp and 0.5-1000 mAs at a source-to-detector distance of 100 cm: (1) X-rays penetrating a soft-tissue-equivalent phantom with the OSL dosimeter attached directly on the phantom, and (2) X-rays penetrating only the soft-tissue-equivalent phantom. Next, the energy fluence and errors in the fluence were calculated from the spectra. When the energy fluence with errors concerning these two experimental conditions was estimated to be indistinctive, we defined the condition as the OSL dosimeter not being identified on the X-ray image. Based on our analysis, we determined the identification limit of the dosimeter. We then compared our results with those for the general irradiation conditions used in clinics. We found that the OSL dosimeter could not be identified under the irradiation conditions of abdominal and chest radiography, namely, one can apply the OSL dosimeter to measurement of the exposure dose in the irradiation field of X-rays without disturbing medical images.

  13. The use of stimulated electron emission (SEE) in homeland security applications

    Science.gov (United States)

    Ing, H.; Andrews, H. R.; Facina, M.; Lee, W. T.; Niu, H. W.

    2012-06-01

    Certain insulating solids can store a fraction of the absorbed energy when irradiated by ionizing radiation. The stored energy can be released subsequently by heating or optical stimulation. As a result, light may be emitted through Thermoluminescence (TL) or Optically-Stimulated Luminescence (OSL) and electrons may be emitted through Thermally-Stimulated Electron Emission (TSEE) or Optically-Stimulated Electron Emission (OSEE). TL and OSL are widely used in current radiation dosimetry systems. However, despite considerable research effort during the early 1970s, SEE was not commonly adopted for dosimetry applications. One of the main reasons is that SEE is a surface phenomenon, while luminescence is a bulk phenomenon, making SEE more susceptible to humidity, absorption of gases, minor physical defects and handling, both before and after irradiation. Nevertheless, it has been recognized that SEE may be useful for homeland security applications in nuclear forensics, where dose accuracy is not the primary performance metric. In this research, we are investigating the use of SEE for nuclear forensic applications. Many common materials, both natural and man-made, exhibit the phenomenon, providing an opportunity to use the environment itself as an in-situ radiation detector. We have designed and constructed a unique prototype reader for conducting SEE measurements. We have demonstrated that the SEE measurements from a variety of materials are quantitatively reproducible and correlated to radiation exposure. Due to the broad applicability of SEE, significant additional studies are warranted to optimize this novel technique for nuclear forensic and other applications.

  14. Optical excitation processes in the near band-edge region of KAlSi3O8 and NaAlSi3O8 feldspar

    DEFF Research Database (Denmark)

    Poolton, N.R.J.; Mauz, B.; Lang, A.

    2006-01-01

    -stimulated phosphorescence and energy-dependent photo-transferred optically stimulated luminescence. The photo-transferred OSL confirms the bandgap energy of alkali feldspars to be 7.7eV at 10K, and highlights the role played by a dominant optically active defect 4.4 eV below the conduction band, associated with blue......)) yielding a characteristically narrow feature at 4.61 eV: significantly, excitation to this level allows photo-transferred OSL to take place, a process that is not obviously identifiable with the other transitions of the set. The conclusion of the work is that synchrotron-based luminescence methods can...

  15. Persistent luminescence, TL and OSL characterization of beta irradiated SrAl2O4:Eu2+, Dy3+ combustion synthesized phosphor

    International Nuclear Information System (INIS)

    Zúñiga-Rivera, N.J.; García, R.; Rodríguez-Mijangos, R.; Chernov, V.; Meléndrez, R.; Pedroza-Montero, M.; Barboza-Flores, M.

    2014-01-01

    The persistent luminescence (PLUM), thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of strontium aluminates co-doped with Eu +2 and Dy +3 exposed to beta radiation is reported. The phosphor was synthesized by the combustion synthesis method employing a highly exothermic redox reaction between the metal nitrates [Al(NO 3 ) 3 , Sr(NO 3 ) 2 , Eu(NO 3 ) 3 and Dy(NO 3 ) 3 ] and organic fuel carbohydrazide (CH 6 N 4 O). The long decay PLUM emission, TL and OSL were measured as a function of beta radiation dose. A wide emission band centered at 510 nm (green) related to Eu 2+ ions and lattice defects were observed for the synthesized samples. The presence of a variety of defects and aggregates were responsible for the observed broad 100 °C peaked TL glow curve of the irradiated sample which is composed of several overlapped TL peaks. The existence of multiple trapping levels, with different trapping/detrapping probabilities, is behind the particular features for the PLUM, TL and OSL emissions. We conclude that in the SrAl 2 O 4 :Eu 2+ , Dy 3+ phosphors, the low temperature TL peaked around 30–75 °C is responsible for the PLUM emission and those around 100 °C were related to very stable trapping states which provide suitable radiation storage properties to be used as a PLUM/TL/OSL radiation phosphor

  16. A new sensitive system for measurement of thermally and optically stimulated luminescence

    DEFF Research Database (Denmark)

    Markey, B.G.; Bøtter-Jensen, L.; Poolton, N.R.J.

    1996-01-01

    optics of the system with a combination of ellipsoidal mirrors and light guides, which also serve to make the system more flexible in choice of excitation source when OSL measurements are required. A variety of new light sources might be employed, adapted to allow the most efficient wavelengths...

  17. OSL and TL dosimeter characterization of boron doped CVD diamond films

    Science.gov (United States)

    Gonçalves, J. A. N.; Sandonato, G. M.; Meléndrez, R.; Chernov, V.; Pedroza-Montero, M.; De la Rosa, E.; Rodríguez, R. A.; Salas, P.; Barboza-Flores, M.

    2005-04-01

    Natural diamond is an exceptional prospect for clinical radiation dosimetry due to its tissue-equivalence properties and being chemically inert. The use of diamond in radiation dosimetry has been halted by the high market price; although recently the capability of growing high quality CVD diamond has renewed the interest in using diamond films as radiation dosimeters. In the present work we have characterized the dosimetric properties of diamond films synthesized by the HFCVD method. The thermoluminescence and the optically stimulated luminescence of beta exposed diamond sample containing a B/C 4000 ppm doping presents excellent properties suitable for dosimetric applications with β-ray doses up to 3.0 kGy. The observed OSL and TL performance is reasonable appropriate to justify further investigation of diamond films as dosimeters for ionizing radiation, specially in the radiotherapy field where very well localized and in vivo and real time radiation dose applications are essential.

  18. Establishing personal dosimetry procedure using optically stimulated luminescence dosimeters in photon and mixed photon-neutron radiation fields

    International Nuclear Information System (INIS)

    Le Ngoc Thiem; Bui Duc Ky; Trinh Van Giap; Nguyen Huu Quyet; Ho Quang Tuan; Vu Manh Khoi; Chu Vu Long

    2017-01-01

    According to Vietnamese Law on Atomic Energy, personal dosimetry (PD) for radiation workers is required periodically in order to fulfil the national legal requirements on occupational radiation dose management. Since the radiation applications have become popular in Vietnamese society, the thermal luminescence dosimeters (TLDs) have been used as passive dosimeters for occupational monitoring in the nation. Together with the quick increase in radiation applications and the number of personnel working in radiation fields, the Optically Stimulated Luminescence Dosimeters (OSLDs) have been first introduced since 2015. This work presents the establishment of PD measuring procedure using OSLDs which are used for measuring photons and betas known as Inlight model 2 OSL (OSLDs-p,e) and for measuring mixed radiations of neutrons, photons and betas known as Inlight LDR model 2 (OSLDs-n,p,e). Such following features of OSLDs are investigated: detection limit, energy response, linearity, reproducibility, angular dependency and fading with both types of OSLDs-p,e and OSLDs-n,p,e. The result of an intercomparison in PD using OSLDs is also presented in the work. The research work also indicates that OSL dosimetry can be an alternative method applied in PD and possibly become one of the most popular personal dosimetry method in the future. (author)

  19. Optical dating of relict sand wedges and composite-wedge pseudomorphs in Flanders, Belgium

    DEFF Research Database (Denmark)

    Buylaert, Jan-Pieter; Ghysels, Günther; Murray, Andrew S.

    2009-01-01

    We report on quartz Optically Stimulated Luminescence (OSL) dating of the infill of 14 relict sand wedges and composite-wedge pseudomorphs at 5 different sites in Flanders, Belgium. A laboratory dose recovery test indicates that the single-aliquot regenerative-dose (SAR) procedure is suitable for...

  20. Assessment of influence of OSL dosimeters in the skin dose in radiotherapy: study for Monte Carlo simulation; Avaliacao da influencia de dosimetros OSL na dose na pele em radioterapia: estudo por simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Schuch, Franciely F.; Nicolucci, Patricia, E-mail: franschuch@yahoo.com.br [Universidade de Sao Paulo (USP), Ribeiraoo Preto, SP (Brazil)

    2017-11-01

    The interest in optically stimulated luminescence (OSL) dosimetry materials is growing due to its potential use in quality control in Radiotherapy. The use of these dosimeters for in vivo dosimetry, however, may influence the dose to the skin and deeper tissues in the patient. The goal of this study is to evaluate the influence of the OSL Al{sub 2}O{sub 3} material in dose deposited in the skin and deep in Radiotherapy. Monte Carlo simulation is used to evaluate this purpose when OSL dosimeters of Al{sub 2}O{sub 3} are positioned on the skin surface of the patient. Percentage depth dose curves for clinical beams of 6 and 10 MV were simulated with and without the presence of the dosimeter on the surface of a water phantom. The results showed a decrease of doses in regions close to the surface of the skin. In the build-up region, the maximum decreases of dose produced by the presence of the dosimeters were 52,5% and 47,5% for the 6 and 10 MV beams, respectively. After the build-up region, there are not significant changes in the doses for any of the used beams. The differences of doses found are due to the influence of the dosimetric material on the relative fluence of electrons near the end surface of the dosimeter. Thus, the results showed that the presence of the dosimetric material on the surface interferes on the skin dose. However, these dosimeters do not cause dose variations in depths of clinical interest, allowing its application in routine in vivo dosimetry in Radiotherapy. (author)

  1. Dose response, thermal stability and optical bleaching of the 310 degrees C isothermal TL signal in quartz

    DEFF Research Database (Denmark)

    Jain, Mayank; Duller, G.A.T.; Wintle, A.G.

    2007-01-01

    , thermal stability and the effects of optical bleaching. The (0-5s) signal shows all order of magnitude higher for saturation level with laboratory dose than the optically stimulated luminescence (OSL) signal, and has a thermal stability that is very sintilar to published values for the OSL or the 325...... degrees C TL peak. Bleaching with a solar simulator reduces both parts of the ITL signal to a low, but non-zero level in a few thousand seconds. This result is supported by an equivalent dose estimate oil a modern river sample from Zambia of 11 +/- 2 Gy. This combination of low residual dose and high...

  2. Investigation of OSL signal of resistors from mobile phones for accidental dosimetry

    International Nuclear Information System (INIS)

    Mrozik, A.; Marczewska, B.; Bilski, P.; Gieszczyk, W.

    2014-01-01

    Resistors from mobile phones, usually located near the human body, are considered as individual dosimeters of ionizing radiation in emergency situations. The resistors contain Al 2 O 3 , which is optically stimulated luminescence (OSL) material sensitive to ionizing radiation. This work is focused on determination of dose homogeneity within mobile phones which was carried out by OSL measurements of resistors placed in different parts inside the mobile phone. Separate, commercially available resistors, similar in the shape and size to the resistors from circuit board of the studied mobile phone, were situated in different locations inside it. The irradiations were performed in uniform 60 Co and 137 Cs radiation fields, with the mobile phones connected and not connected to the cellular network. The dose decrease of 9% was measured for original resistors situated between circuit board and battery, in comparison to the dose at the front of the phone. The resistors showed the lower signal when the mobile phone was connected to the cellular network, due to higher temperature inside the housing. The profile of fading was investigated within 3 month period for resistors irradiated with 1 Gy of gamma rays to estimate of the fading coefficient. - Highlights: • Impact of a mobile phone mode (switched on/off) on absorbed dose by resistors was showed. • The influence of the temperature during irradiation on absorbed dose was measured. • Dose distribution inside of a mobile phone was performed. • Fading factor of resistors was calculated

  3. OSL and IRSL characteristics of quartz and feldspar from southern California, USA

    International Nuclear Information System (INIS)

    Lawson, Michael J.; Roder, Belinda J.; Stang, Dallon M.; Rhodes, Edward J.

    2012-01-01

    Southern California comprises of a wide range of diverse landscapes and environments, from high mountains with glacial and periglacial sediments to deserts with large sand dunes, extensive alluvial fans and ephemeral playas. Highly active tectonic processes has exposed ancient (c. 2 Ga) plutonic and metamorphic basement from deep within the crust, while similar Palaeozoic, Mesozoic and Cenozoic rocks are also common. A rich array of volcanic lithologies extending into the late Quaternary complement many thick sedimentary sequences that formed in equally diverse ancient environments typical of an accreting active continental margin. In some locations, notably in the Coachella Valley close to Palm Springs and the Salton Sea, low OSL sensitivity and poor characteristics restrict the application of the quartz SAR protocol to date late Pleistocene and Holocene fluvial sediments. In other locations such as the Malibu coastline, high sensitivity of the quartz OSL signal is observed, despite local source rocks being dominated by volcanic lithologies. Problems of poor quartz characteristics, along with uncertainty in predicting quartz OSL behavior for future dating campaigns poses a significant problem for projects, in particular for neotectonic contexts. While K-feldspar has been used extensively to date eolian and fluvial sediments in southern California, little information regarding signal stability is available. We explore the characteristics of both quartz and feldspar sub-samples from eolian, fluvial, lacustrine environments, in order to help develop mineral selection criteria for optical dating applications and clarify these issues. The importance of radiation quenching in quartz grains recently eroded from bedrock and the role of fires in enhancing OSL sensitivity are considered. The relative bleachability of quartz and feldspar fractions, along with thermal stability considerations is discussed. A simple test for quartz OSL signal contamination based on thermal

  4. Yellow stimulated luminescence from potassium feldspar: Observations on its suitability for dating

    International Nuclear Information System (INIS)

    Lauer, T.; Krbetschek, M.; Mauz, B.; Frechen, M.

    2012-01-01

    Yellow stimulated luminescence (Y-OSL) is the light detected from potassium-rich feldspars at 410 nm under stimulation by a yellow light source emitting 590 nm. The investigation of this study aimed at understanding basic luminescence physics of Y-OSL in order to assess the suitability of the technique for dating. The Y-OSL signal properties tested were signal intensity, thermal assistance, thermal stability, sensitivity to daylight and the suitability of a single aliquot regenerative (SAR) protocol to be employed for equivalent dose (D e ) estimation. D e measurements were conducted on samples of Holocene, last glacial and Tertiary age. The tests were undertaken on sedimentary feldspar separates extracted from aeolian, fluvial and coastal deposits. Results from experiments show that the signal intensity increases by measuring Y-OSL at elevated temperature suggesting thermal assistance characteristics similar to infrared stimulated luminescence (IRSL). The yellow stimulated signal remains unaffected by preheat temperatures up to ∼200 °C suggesting higher thermal stability than the IRSL signal. The Y-OSL signal is less light sensitive than the IRSL signal and D e residuals obtained from modern samples are up to 7 Gy indicating suitability of the technique for ‘older’ and well-bleached sediments. The dose recovery tests successfully recovered the given dose if the specific light sensitivity of Y-OSL is taken into account. For every sample Y-OSL D e values obtained by a single aliquot regenerative dose protocol (SAR) are higher than those obtained by an IRSL SAR approach. From these results we infer high thermal stability and a minimal anomalous fading of the Y-OSL signal. We conclude that Y-OSL has a high potential to date Quaternary sediments that were sufficiently bleached in nature.

  5. A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Da; Li, Xinhua; Liu, Bob [Division of Diagnostic Imaging Physics and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Gao, Yiming; Xu, X. George [Nuclear Engineering Program, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States)

    2013-08-15

    Purpose: To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters “nanoDots” and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method—a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future.Methods: A standard ATOM phantom has densely located holes (in 3 × 3 cm or 1.5 × 1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified the conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations.Results: Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated

  6. A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms

    International Nuclear Information System (INIS)

    Zhang, Da; Li, Xinhua; Liu, Bob; Gao, Yiming; Xu, X. George

    2013-01-01

    Purpose: To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters “nanoDots” and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method—a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future.Methods: A standard ATOM phantom has densely located holes (in 3 × 3 cm or 1.5 × 1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified the conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations.Results: Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated

  7. Optical stimulator for vision-based sensors

    DEFF Research Database (Denmark)

    Rössler, Dirk; Pedersen, David Arge Klevang; Benn, Mathias

    2014-01-01

    We have developed an optical stimulator system for vision-based sensors. The stimulator is an efficient tool for stimulating a camera during on-ground testing with scenes representative of spacecraft flights. Such scenes include starry sky, planetary objects, and other spacecraft. The optical...

  8. Optical dating of the hydroponic farm at Korea

    International Nuclear Information System (INIS)

    Hong, D.G.; Galloway, R.B.; Kim, M.J.; Park, S.B.

    2003-01-01

    For age determination, the single aliquot regenerative-dose (SAR) method was applied to quartz from archaeological materials, using luminescence stimulated by blue light. The quartz samples were extracted from sediment from the hydroponic farm related to rice cultivation in an area of archaeological interest in Buyeo, south of Seoul. The optically stimulated luminescence (OSL) dates obtained offered good agreement with the ages derived by typological assessment and 14 C ages. These ages should contribute significantly to interpretation of the history of rice cultivation in Korea. (author)

  9. TL/OSL properties of natural schist for archaeological dating and retrospective dosimetry

    International Nuclear Information System (INIS)

    Afouxenidis, D.; Stefanaki, E.C.; Polymeris, G.S.; Sakalis, A.; Tsirliganis, N.C.; Kitis, G.

    2007-01-01

    Schist, a metamorphic rock composed largely of quartz and muscovite, has been used as a building stone through the centuries in many parts of the world. In ancient Greece, it was used in buildings and monuments (Knossos, Karthaia, etc). Basic TL and OSL properties of schist are studied in the present work to evaluate its potential use in archaeological dating and retrospective dosimetry. In particular, the optical stability, as well as the linearity of the TL and OSL signal were investigated for samples of natural schist obtained from a roofing slate. The results indicate that both signals are rapidly bleached when the sample is exposed to sunlight. An exposure of 1 min reduces the TL signal by 93%, the IRSL signal by 99% and the post-IR BSL signal by 90%. The dose response was found to be linear for a radiation dose at least up to 75 Gy for the TL and the IR OSL signal and at least up to 25 Gy for the post-IR BSL signal

  10. Persistent luminescence, TL and OSL characterization of beta irradiated SrAl{sub 2}O{sub 4}:Eu{sup 2+}, Dy{sup 3+} combustion synthesized phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Zúñiga-Rivera, N.J. [Departamento de Física, Posgrado en Nanotecnología, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico); García, R.; Rodríguez-Mijangos, R.; Chernov, V.; Meléndrez, R.; Pedroza-Montero, M. [Departamento de Investigación en Física, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico); Barboza-Flores, M., E-mail: mbarboza@cifus.uson.mx [Departamento de Investigación en Física, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico)

    2014-05-01

    The persistent luminescence (PLUM), thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of strontium aluminates co-doped with Eu{sup +2} and Dy{sup +3} exposed to beta radiation is reported. The phosphor was synthesized by the combustion synthesis method employing a highly exothermic redox reaction between the metal nitrates [Al(NO{sub 3}){sub 3}, Sr(NO{sub 3}){sub 2}, Eu(NO{sub 3}){sub 3} and Dy(NO{sub 3}){sub 3}] and organic fuel carbohydrazide (CH{sub 6}N{sub 4}O). The long decay PLUM emission, TL and OSL were measured as a function of beta radiation dose. A wide emission band centered at 510 nm (green) related to Eu{sup 2+} ions and lattice defects were observed for the synthesized samples. The presence of a variety of defects and aggregates were responsible for the observed broad 100 °C peaked TL glow curve of the irradiated sample which is composed of several overlapped TL peaks. The existence of multiple trapping levels, with different trapping/detrapping probabilities, is behind the particular features for the PLUM, TL and OSL emissions. We conclude that in the SrAl{sub 2}O{sub 4}:Eu{sup 2+}, Dy{sup 3+} phosphors, the low temperature TL peaked around 30–75 °C is responsible for the PLUM emission and those around 100 °C were related to very stable trapping states which provide suitable radiation storage properties to be used as a PLUM/TL/OSL radiation phosphor.

  11. On the effect of optical and isothermal treatments on luminescence signals from feldspars

    International Nuclear Information System (INIS)

    Pagonis, Vasilis; Polymeris, George; Kitis, George

    2015-01-01

    During luminescence dosimetry and luminescence dating applications it is often necessary to precondition the geological samples by applying a thermal or optical treatment before measuring the luminescence signal. In luminescence applications using apatites or feldspars, measurement of continuous-wave infrared or optically stimulated signals (CW-IRSL and CW-OSL) are customarily preceded by either an isothermal heating of the samples at a fixed temperature for a short time interval, or alternatively by optically bleaching the samples using light from LEDs with the appropriate wavelength. This paper presents new analytical equations which can be used to describe these commonly employed double experimental procedures. The equations are based on a recently published model which assumes that tunneling processes are taking place in random distributions of donor–acceptor pairs. The concentration of charge carriers during the CW-IRSL or CW-OSL experiment is expressed in terms of the parameters of the preceding thermal or optical bleaching procedure, and depends also on the distribution of distances between electron and hole pairs. The analytical equations in this paper are compared with experimental data from a feldspar sample which undergoes an isothermal procedure followed by measurement of the CW-IRSL signal. Additional comparisons with experiment are provided using a feldspar sample which undergoes an infrared bleaching process, followed by measurement of the CW-OSL signal. These results and conditions under which the equations can be used are discussed within the framework of the model. - Highlights: • CW-IRSL and CW-OSL measurements are preceded by heating or optical bleaching. • New analytical equations are derived to describe these double experimental procedures. • Equations are compared with data from a feldspar sample following isothermal procedure. • Equations are compared with data from a feldspar sample following optical bleaching.

  12. Detection of herbs and spices irradiated through optically stimulated luminescence

    International Nuclear Information System (INIS)

    Preciado, S.; Agundez A, Z.; Barboza F, M.; Cruz Z, E.

    2003-01-01

    The irradiation of foods is one of the common practices in several countries of the American and European continents. In spite of the widespread use of irradiation methods and technics of nutritious products, it doesn't exist a method of general use at the present time for the detection of previously submitted foods to irradiation with pasteurization ends or sterilization. In the present work the results are presented obtained in the detection of herbs and spices exposed to radiation in the range of 0.1 - 3 KGy, by means of the photostimulation with light of 470 nm. It was used for it a RIS0 model team TL/OSL-GIVE-15 conditioned with a β ray source, 90 Sr/ 90 Y and a source of light of 50 mW/cm2. samples of chili guajillo were studied, pepper, cumin, mint and camomile; achieving you to detect exhibitions of the order of 8.33x10 -4 KGy that which is indicative of the high sensitivity of the luminescence technique optically stimulated. The answer of the samples with regard to the radiation dose presents a range of lineality for low dose of the order of 0.5 KGy; and supralineal for further dose without to arrive to a saturation stage. (Author)

  13. Optical dating of fluvio-deltaic clastic lake-fill sediments - A feasibility study in the Holocene Rhine delta (western Netherlands)

    NARCIS (Netherlands)

    Wallinga, J.; Bos, I.J.

    2010-01-01

    We test the applicability of quartz optically stimulated luminescence (OSL) dating on clastic lake sediments to investigate whether this dating method can be applied to study the timing and rate of deposition in Holocene fluvio-deltaic lakes. Our study concerns the filling of a lake by the

  14. Dose evaluation using multiple-aliquot quartz OSL: Test of methods and a new protocol for improved accuracy and precision

    DEFF Research Database (Denmark)

    Jain, M.; Bøtter-Jensen, L.; Singhvi, A.K.

    2003-01-01

    -dose-dependent sensitivity changes during the pre-heat, and fundamental variability in the shapes of quartz OSL (blue-green or blue-light stimulated luminescence) decay forms. A new protocol using a combination of 'elevated temperature IR cleaning' (ETIR) and 'component-specific dose normalisation' (CSDN) has been developed....... CSDN accounts for variability in the OSL decay forms and absorbs such sensitivity changes. A combination of ETIR and CSDN protocol increased palaeodose precision from +/-100% to +/-4% in quartz separates from the fluvially transported sands in the Thar desert. A comparison with palaeodose estimates...

  15. High-resolution OSL chronology of a sediment core from Lake Nam Co on the southern Tibetan Plateau: Comparison with radiocarbon dating

    Science.gov (United States)

    Long, Hao; Shen, Ji; Haberzettl, Torsten; Fuchs, Markus; Frechen, Manfred; Wang, Junbo

    2013-04-01

    Numerous studies on lake sediment cores from the Tibetan Plateau aimed to reconstruct spatial and temporal changes of the late Glacial and Holocene monsoon variations, which are characterized by fluctuations in precipitation and expansion of monsoonal air masses across the Plateau. Accurate and reliable dating of lacustrine deposits is of crucial importance in both the reconstruction of palaeolake and palaeoclimate evolution and the understanding of the mechanisms for climate changes, especially abrupt changes of regional-hemispheric hydrological circulation. Radiocarbon dating is the most commonly used method for establishing chronologies of lake sediments. However, 14C dating of such sediments could be problematic due to the lack of organic matter or a reservoir effect, which appears common in radiocarbon dating of lacustrine sediments from the Tibetan Plateau. In this study, ca. 10.5 m long core (NC core) was retrieved from the water depth of 93 m at Nam Co Lake, which is the second largest saline lake in China, located on the southern Tibetan Plateau. For this core, high-resolution samples (23 samples) were obtained for optically stimulated luminescence (OSL) dating. Quartz of fine-grain (4-11 μm) fraction were extracted from this samples for OSL dating, which is compared with the 14C chronology of NC core based on accelerator mass spectrometry (AMS) dating of bulk organic matter of 22 samples. The sample from the top of NC core was dated to approximate zero age, indicating the sediments bleached well before deposition. Luminescence behaviors of the study samples further confirmed the robustness of OSL ages. Comparison between OSL and 14C ages suggested that: (1) two kinds of ages are in agreement within error from top to 1.8 m, (2) from 1.8 m to the base of NC core, the 14C ages show a general trend to ca. 4 ka higher ages than the OSL ages. Although 14C dating overestimate the ages from 1.8 m to base, they still show the general trend in sedimentation rate

  16. Development of pulsed stimulation and Photon Timer attachments to the Risø TL/OSL reader

    DEFF Research Database (Denmark)

    Lapp, Torben; Jain, Mayank; Ankjærgaard, Christina

    2009-01-01

    in the OSL/IRSL process, a Photon Timer attachment to the Risø reader has been developed which measures data at 100 ps resolution. Furthermore a post-processing program has been developed to present the data in a compressed 3D form that gives a useful overview of the data before further analysis of relevant...

  17. Optical annealing of CaF2:Mn for cooled optically stimulated luminescence

    International Nuclear Information System (INIS)

    Miller, S.D.; Stahl, K.A.; Endres, G.W.R.; McDonald, J.C.

    1989-01-01

    Optical annealing of the cooled optically stimulated luminescence in CaF 2 :Mn at room temperature has been demonstrated. The laser of choice for optical annealing of CaF 2 : Mn is a 326 nm helium-cadmium ultraviolet laser. A complete cycle of readout and annealing of the CaF 2 :Mn cooled optically stimulated dosemeters can now be accomplished without heating the dosemeters above room temperature. This annealing work represents the next step toward creating a proton-recoil-based fast neutron dosimetry system based on the cooled optically stimulated luminescence technique. (author)

  18. Thyroid dose measurement in patients undergoing to digital orthopantomography using optical stimulation dosimeters; Medicion de dosis en tiroides en pacientes sometidos a ortopantografia digital utilizando dosimetros de estimulacion optica

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez M, J. G.; Lopez V, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Calz. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Avalos P, L. Y., E-mail: jggm25@yahoo.com.mx [UNAM, Facultad de Odontologia, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico)

    2016-10-15

    In this paper we present the study of the thyroid equivalent dose in 300 patients undergoing to digital orthopantomography for dental treatment purposes using optical stimulation dosimeters (OSL) as in-vivo dosimeters, in order to verify if this is within acceptable parameters to prevent stochastic risks and to evaluate the possible risks caused by the technique used for this type of study (66 kv, 5 m A, 14.1 s). Three OSL dosimeters were used per patient, which were placed by the physician on the skin above the thyroid gland (using anatomical references and palpation); the information of the patients was divided by neck size and sex, finding a slight increase in the equivalent dose for female and small size patient, this combination being the group that was submitted to a higher dose. The results obtained were compared with similar studies performed on anthropomorphic mannequins with TLD dosimeters obtaining lower results. The equivalent dose found even though is below the threshold stochastic damage must be motorized for radiological protection and registration purposes. (Author)

  19. SU-F-P-50: Performance Evaluation of Optically Stimulated Luminescence (OSL) NanoDots in Therapy and Imaging In-Vivo Dose Measurement During Patient Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S; Sarkar, B; Kaur, H; Rathinamuthu, S; Giri, U; Jassal, K; Ganesh, T; Munshi, A; Mohanti, B; Krishnankutty, S; Sathiya, J [Fortis Memorial Research Institute, Gurgaon, Haryana (India)

    2016-06-15

    Purpose: This study was designed to evaluate the performance of optically stimulated Luminescence (OSL) nanoDots as in-vivo dosimeter. For the measurements of surface doses as well as scattered plus leakage doses, nanoDots were used during the setup verification as well as during the treatment delivery. Methods: For a total seven patients undergoing radiotherapy by volumetric modulated arc therapy, surface doses from image guidance and scattered plus leakage doses from treatment delivery were measured. Two sets of calibration curves were generated – one for therapy and another for imaging. Two different nanoDots were used for imaging and therapy doses. Imaging nanoDots were placed at the isocenter only at the time of CBCT and therapy nanoDots were placed at 25 cm away from the isocenter (either in cranial or in caudal direction) only at the time of treatment delivery. During the entire course, nanoDots were placed at the same measurement points. NanoDots were read after 15 minutes of their exposure. For the next fraction, nanoDots were corrected for the residual doses from the previous fractions. Results: Measured surface doses during imaging were 0.14±0.32 cGy, 0.11±0.04 cGy, 0.12±0.53 cGy, 0.04±0.02 cGy, 0.13±0.23 cGy, 0.11±0.43 cGy, 0.10±0.04 cGy with overall mean dose of 0.08±0.1 cGy. Measured doses during treatment delivery, indicative of scattered and leakage dose, were 0.84±0.43 cGy, 1.3±0.4 cGy, 1.4±0.4 cGy, 0.18±0.48 cGy, 0.78±0.29 cGy, 0.27±0.08 cGy, 0.78±0.07 cGy with overall mean dose of 0.61±1.3 cGy. Conclusion: This dosimeter can be used as supplementary unit to verify the doses. No change in the prescription is recommended based on nanoDots measurement. This study is on-going therefore we are presenting only mere number of patients. A large volume data will be presented after completion of the study with proper statistical analysis.

  20. Application of pulsed OSL to the separation of the luminescence components from a mixed quartz/feldspar sample

    DEFF Research Database (Denmark)

    Denby, Phil M.; Bøtter-Jensen, L.; Murray, A.S.

    2006-01-01

    with a feldspar signal. We have developed instrumentation for the study of high-speed pulse stimulated OSL. Our system uses the standard blue/IR LED stimulation unit of a Riso reader (allowing stimulation pulses down to 1-2 mu s duration) and can thus be applied to the routine analysis of samples. Using...... that counts are only accumulated during a windowed period, reduces the feldspar signal to 1.6% of its original value relative to that of the quartz. (c) 2006 Elsevier Ltd. All rights reserved....

  1. Optically stimulated luminescence dating of young sediments

    DEFF Research Database (Denmark)

    Madsen, Anni Tindahl; Murray, Andrew S.

    2009-01-01

    of OSL dating, outlines the problems specific to the dating of young material, and then uses recent applications to young sediments to illustrate the greatly increased scope and potential of the method in geomorphology and the geology of recent deposits. The overall reliability of this new generation...... for determining the time of deposition of water-lain sediments from the coastal zone, and aeolian deposits from both coastal and inland environments. Our conclusion is supported by the growing popularity of OSL dating in geomorphology and geology...

  2. Characterisation of blue-light stimulated luminescence components in different quartz samples: Implications for dose measurement

    DEFF Research Database (Denmark)

    Jain, M.; Murray, A.S.; Bøtter-Jensen, L.

    2003-01-01

    -aliquot dose-evaluation protocols seem to be relatively free of complications when applied to quartz dominated by the fast OSL component coming from 325degreesC TL region, but this may not be true for quartz in which other components are more significant. An adequate understanding of how different OSL...... results from measurement of (a) sensitisation, (b) thermal stability, (c) recuperation, and (d) infrared response as a function of stimulation temperature from 3 different samples of sedimentary quartz selected on the basis of relative OSL contribution from different blue light stimulated linearly...

  3. The problem of dating quartz 2: Synchrotron generated X-ray excited optical luminescence (XEOL) from quartz

    International Nuclear Information System (INIS)

    King, G.E.; Finch, A.A.; Robinson, R.A.J.; Taylor, R.P.; Mosselmans, J.F.W.

    2011-01-01

    The luminescence emission of quartz is used in optically stimulated luminescence dating (OSL), however the precise origins of the emission are unclear. A suite of quartz samples were analysed using X-ray excited optical luminescence (XEOL). Radiation dose effects were observed whereby the UV emissions (3.8 and 3.4 eV) were depleted to the benefit of the red emission (1.9-2.0 eV). Samples were excited at ∼7 keV. Understanding why some quartz emit light more brightly than others will increase the efficiency and precision of OSL analyses. - Highlights: → The X-ray excited optical luminescence (XEOL) emission of quartz is explored. → The XEOL of quartz of different provenances varies. → Radiation dosing causes UV emissions to deplete to the benefit of red emissions. → The 3.8 and 3.4 eV emissions deplete at the same rate. → The quartz luminescence emission exhibits anisotropic effects.

  4. The TL and room temperature OSL properties of the glow peak at 110 deg. C in natural milky quartz: A case study

    International Nuclear Information System (INIS)

    Polymeris, George S.; Afouxenidis, Dimitrios; Tsirliganis, Nestor C.; Kitis, George

    2009-01-01

    The LM-OSL signal of quartz, while measured at room temperature, is dominated by an intermediate, broad and intense OSL component, so that its contribution and general characteristics are derived very accurately. Through a series of dose-response, bleaching and thermal decay at room temperature experiments, in conjunction with curve fitting studies, a component resolved analysis is carried out studying the correlation between this specific component, termed as LM-OSL component C 2 and the 110 deg. C TL glow peak in quartz. The dose-response of these two luminescence components behaves exactly similar being linear at low doses and saturating at almost 100 Gy. Both signals decay exponentially under illumination, providing identical optical detrapping cross-section values. Residual of both luminescence signals after thermal decay at room temperature follows an exponential law, yielding similar mean half-lives. All previous luminescence features provide strong evidence for the electron trap being the same for both the 110 deg. C TL trap and the LM-OSL component C 2 . The results of the present work are very promising and clearly support the possibility of extrapolating the TL pre-dose methodology to the OSL pre-dose effect using only the LM-OSL component C 2

  5. Study of TSL and OSL properties of dental ceramics for accidental dosimetry applications

    International Nuclear Information System (INIS)

    Veronese, Ivan; Galli, Anna; Cantone, Marie Claire; Martini, Marco; Vernizzi, Fabrizio; Guzzi, Gianpaolo

    2010-01-01

    Interest is increasing in the development of new methodologies for accidental dose assessment, exploiting the luminescence and dosimetric properties of objects and materials which can be usually found directly on exposed subjects and/or in the contaminated area. In this work, several types of ceramics employed for dental prosthetics restoration, including both innovative materials used as sub-frames for the construction of the inner part of dental crowns (core), and conventional porcelains used for the fabrication of the external layer (veneer), were investigated with regard to their thermally and optically stimulated luminescence (TSL and OSL respectively) properties, in view of their potential application in accidental dosimetry. The sensitivity to ionizing radiation proved to strongly depend on the type and brand of ceramic, with minimum detectable dose ranging from few mGy up to several tens of mGy. A linear dose-response was observed for most of the samples. However, the luminescence signals were characterised by a significant fading, which has to be taken into account for a reliable accidental dose assessment after a radiation exposure event.

  6. Optically stimulated luminescence techniques in retrospective dosimetry using single grains of quartz extracted from unheated materials

    Energy Technology Data Exchange (ETDEWEB)

    Joerkov Thomsen, Kristina

    2004-02-01

    This work investigates the possibility of applying optically stimulated luminescence (OSL) in retrospective dose determinations using unheated materials. It focuses on identifying materials suitable for use in assessment of doses absorbed as a consequence of radiation accidents (i.e. accident dosimetry). Special attention has been paid to quartz extracted from unheated building materials such as concrete and mortar. The single-aliquot regeneration-dose (SAR) protocol has been used to determine absorbed doses in small aliquots as well as single grains of quartz. It is shown that OSL measurements of single grains of quartz extracted from poorly-bleached building materials can provide useful information on radiation accident doses, even when the luminescence sensitivity is low. Sources of variance in well-bleached single grain dose distributions have been investigated in detail and it is concluded that the observed variability in the data is consistent with the sum (in quadrature) of a component, which depends on the number of photons detected from each grain, and a fixed component independent of light level. Dose depth profiles through laboratory irradiated concrete bricks have successfully been measured and minimum detection limits of less than 100 mGy are derived. Measurements of thermal transfer in single grains of poorly-bleached quartz show that thermal transfer is variable on a grain-to-grain basis and that it can be a source of variance in single-grain dose distributions. Furthermore, the potential of using common household and workplace chemicals, such as table salt, washing powder and water softener, in retrospective dosimetry has been investigated. It is concluded that such materials should be considered as retrospective dosimeters in the event of a radiation accident. (au)

  7. An investigation of coseismic OSL / TL time zeroing of quartz gouge based on low- to high-velocity friction experiments

    Science.gov (United States)

    Akasegawa, K.; Oohashi, K.; Hasebe, N.; Miura, K.

    2016-12-01

    To determine an age of coseismic event of an active fault, we generally examine crosscutting relationship between faults and overlying strata by trenching. However, we could not apply this method in case there are no overlying young strata in the vicinity of the fault zones. The alternative is a dating of fault zone materials whose age experienced resetting with seismic fault slip (for example, the ESR method;. Ikeya et al,1982; the OSL and TL methods). The idea behinds to the OSL (optically stimulated luminescence) and TL (thermoluminescence) dating methods for a determination of paleo-earthquake event is the accumulated natural radiation damage becomes to zero (time zeroing) by the frictional heating and grinding. However, physical and geological conditions required to induce time zeroing is not well understood because there is only few experimental investigations under the limited conditions (Hiraga et al,2004;. Kim et al, 2014) . In this study, we conduct low- to high-velocity friction experiments using quartz gouge under various experimental conditions (e.g., normal stress, displacement, moisture content) to establish an empirical relationship and physical and geological conditions of coseismic OSL time zeroing. In this experiment, we carry out the friction experiments using quartz in Tsushigawa granite taken from the east wall of the Nojima fault Ogura trench site, which was excavated in 2015. Samples were taken from the most distant position from the fault in the trench site. The samples were clashed using a mortar and sieved to a grain size of treatment. The residual is user for the friction experiments after having known radiation dose using an artificial gamma-ray source. In this presentation, we show results of the friction experiments and dating of the quartz gouge and discuss physical and geological conditions of OSL time zeroing. References Okumura, T., and Shitaoka, Y., 2011. Engineering Geology of Japan, No. 1, 5-17. Hiraga, S., Yoshimoto, A., and

  8. On the use of OSL of chip card modules with molding for retrospective and accident dosimetry

    International Nuclear Information System (INIS)

    Woda, Clemens; Fiedler, Irene; Spöttl, Thomas

    2012-01-01

    The potential of optically stimulated luminescence of wire-bond chip card modules with molded encapsulations for retrospective and accident dosimetry is investigated. Contact-based and contactless modules were studied, the latter finding potential use in electronic documents (e.g. electronic passports, electronic identity cards). Investigations were carried out on intact as well as chemically prepared modules, extracting the filler material. Contact-based modules are characterized according to zero dose signal, correlation between OSL and TL, dose response and long-term signal stability. For prepared modules, the minimum detectable dose immediately after irradiation is 3 mGy and between 20 and 200 mGy for contact-based and contactless modules, respectively. Dose recovery tests on contact-based modules indicate that the developed methodology yields results with sufficient accuracy for measurements promptly after irradiation, whereas a systematic underestimation is observed for longer delay times. The reasons for this behaviour are as yet not fully understood.

  9. EDITORIAL: Special issue on optical neural engineering: advances in optical stimulation technology Special issue on optical neural engineering: advances in optical stimulation technology

    Science.gov (United States)

    Shoham, Shy; Deisseroth, Karl

    2010-08-01

    Neural engineering, itself an 'emerging interdisciplinary research area' [1] has undergone a sea change over the past few years with the emergence of exciting new optical technologies for monitoring, stimulating, inhibiting and, more generally, modulating neural activity. To a large extent, this change is driven by the realization of the promise and complementary strengths that emerging photo-stimulation tools offer to add to the neural engineer's toolbox, which has been almost exclusively based on electrical stimulation technologies. Notably, photo-stimulation is non-contact, can in some cases be genetically targeted to specific cell populations, can achieve high spatial specificity (cellular or even sub-cellular) in two or three dimensions, and opens up the possibility of large-scale spatial-temporal patterned stimulation. It also offers a seamless solution to the problem of cross-talk generated by simultaneous electrical stimulation and recording. As in other biomedical optics phenomena [2], photo-stimulation includes multiple possible modes of interaction between light and the target neurons, including a variety of photo-physical and photo-bio-chemical effects with various intrinsic components or exogenous 'sensitizers' which can be loaded into the tissue or genetically expressed. Early isolated reports of neural excitation with light date back to the late 19th century [3] and to Arvanitaki and Chalazonitis' work five decades ago [4]; however, the mechanism by which these and other direct photo-stimulation, inhibition and modulation events [5-7] took place is yet unclear, as is their short- and long-term safety profile. Photo-chemical photolysis of covalently 'caged' neurotransmitters [8, 9] has been widely used in cellular neuroscience research for three decades, including for exciting or inhibiting neural activity, and for mapping neural circuits. Technological developments now allow neurotransmitters to be uncaged with exquisite spatial specificity (down to

  10. Enhancing and quenching luminescence with gold nanoparticle films: the influence of substrate on the luminescent properties

    International Nuclear Information System (INIS)

    Guidelli, Eder José; Baffa, Oswaldo; Ramos, Ana Paula

    2016-01-01

    Gold nanoparticle (AuNP) films were sputtered over glass and aluminum substrates to enhance optically stimulated luminescence (OSL), a luminescent technique employed for radiation detection, from x-ray irradiated NaCl nanocrystals. The AuNP films deposited over glass led to enhanced-OSL emission, whereas the AuNP films deposited on aluminum substrates quenched the OSL emission. The enhanced-OSL intensity is proportional to the optical density of the film's plasmon resonance band at the stimulation wavelength. For the case of the AuNP/aluminum films, the luminescence quenching diminishes, and OSL intensity partially recovers upon increasing the distance between the AuNPs and the aluminum substrates, and between the luminescent nanocrystals and the AuNP films. These results suggest that plasmonic interactions between the emitter nanocrystals, the localized surface plasmons (LSP) of the AuNPs, and the substrate are responsible for the OSL enhancement and quenching. In this sense, the substrate dictates whether LSP relaxation occurs by radiative or non-radiative transisitions, leading to enhanced or quenched OSL, respectively. Therefore, besides showing that AuNP films can enhance and/or tune the sensitivity of luminescent radiation detectors, and demonstrating OSL as a new technique to investigate mechanisms of plasmon-enhanced luminescence, these results bring insights on how substrates strongly modify the optical properties of AuNP films. (paper)

  11. Optical stimulation of peripheral nerves in vivo

    Science.gov (United States)

    Wells, Jonathon D.

    This dissertation documents the emergence and validation of a new clinical tool that bridges the fields of biomedical optics and neuroscience. The research herein describes an innovative method for direct neurostimulation with pulsed infrared laser light. Safety and effectiveness of this technique are first demonstrated through functional stimulation of the rat sciatic nerve in vivo. The Holmium:YAG laser (lambda = 2.12 mum) is shown to operate at an optimal wavelength for peripheral nerve stimulation with advantages over standard electrical neural stimulation; including contact-free stimulation, high spatial selectivity, and lack of a stimulation artifact. The underlying biophysical mechanism responsible for transient optical nerve stimulation appears to be a small, absorption driven thermal gradient sustained at the axonal layer of nerve. Results explicitly prove that low frequency optical stimulation can reliably stimulate without resulting in tissue thermal damage. Based on the positive results from animal studies, these optimal laser parameters were utilized to move this research into the clinic with a combined safety and efficacy study in human subjects undergoing selective dorsal rhizotomy. The clinical Holmium:YAG laser was used to effectively stimulate human dorsal spinal roots and elicit functional muscle responses recorded during surgery without evidence of nerve damage. Overall these results predict that this technology can be a valuable clinical tool in various neurosurgical applications.

  12. An optical age chronology of late Quaternary extreme fluvial events recorded in Ugandan dambo soils

    Science.gov (United States)

    Mahan, S.A.; Brown, D.J.

    2007-01-01

    There is little geochonological data on sedimentation in dambos (seasonally saturated, channel-less valley floors) found throughout Central and Southern Africa. Radiocarbon dating is problematic for dambos due to (i) oxidation of organic materials during dry seasons; and (ii) the potential for contemporary biological contamination of near-surface sediments. However, for luminescence dating the equatorial site and semi-arid climate facilitate grain bleaching, while the gentle terrain ensures shallow water columns, low turbidity, and relatively long surface exposures for transported grains prior to deposition and burial. For this study, we focused on dating sandy strata (indicative of high-energy fluvial events) at various positions and depths within a second-order dambo in central Uganda. Blue-light quartz optically stimulated luminescences (OSL) ages were compared with infrared stimulated luminescence (IRSL) and thermoluminescence (TL) ages from finer grains in the same sample. A total of 8 samples were dated, with 6 intervals obtained at ???35, 33, 16, 10.4, 8.4, and 5.9 ka. In general, luminescence ages were stratigraphically, geomorphically and ordinally consistent and most blue-light OSL ages could be correlated with well-dated climatic events registered either in Greenland ice cores or Lake Victoria sediments. Based upon OSL age correlations, we theorize that extreme fluvial dambo events occur primarily during relatively wet periods, often preceding humid-to-arid transitions. The optical ages reported in this study provide the first detailed chronology of dambo sedimentation, and we anticipate that further dambo work could provide a wealth of information on the paleohydrology of Central and Southern Africa. ?? 2006 Elsevier Ltd. All rights reserved.

  13. OSL and TL of Resistors of Mobile Phones for Retrospective Accident Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. I.; Kim, J. L.; Pradhan, A. S.; Chang, I.; Kim, B. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    Optically stimulated luminescence (OSL) and thermoluminescence (TL) of ubiquitous materials continue to draw wider attention for individual dosimetry in nuclear and radiation accidents. Use of ubiquitous objects for radiation dosimetry is preferred because the affected persons in such unexpected events are usually not covered by personal dosimetry services and do not carry personal dosimeters. Often accident sites do not have area monitoring system in place. As the main concern of the dosimetry is health effects, a quick distinction of level of exposures of the affected persons for the required medical care becomes important in all accidents involving radiation. Both in large scale nuclear accidents such Fukushima, Chernobyl or Hiroshima and Nagasaki where large population around the accident site get exposed to radiation (evacuation is based on doses) and in smaller but panicky events, such as misuse of radiological exposure device (RED), radiological dispersive device (RDD: 'Dirty Bomb'), improvised nuclear device (IND) and deliberate dispersal of radioactive contaminants, a need for an ubiquitous personal dosimeter is well recognized. As biological dosimetry systems are yet to become viable for measurements of doses with required accuracy and speed, use of physical dosimeters is often explored. Among the various types of physical dosimetry systems, use of TL and OSL by processing common material such as bricks or tiles and measuring the doses cumulated for long periods of time has already become an accepted tool for large scale nuclear accidents such as Hiroshima and Nagasaki or Chernobyl involving higher doses. In the other potential cases of unexpected situations where the doses encountered could be much lower (even to escape the range of remotely installed area monitors), the need to measure even the low doses in shortest possible time becomes important. It is often realized that in such situations, the main problem could become the panic at the

  14. OSL and TL of Resistors of Mobile Phones for Retrospective Accident Dosimetry

    International Nuclear Information System (INIS)

    Lee, J. I.; Kim, J. L.; Pradhan, A. S.; Chang, I.; Kim, B. H.

    2012-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence (TL) of ubiquitous materials continue to draw wider attention for individual dosimetry in nuclear and radiation accidents. Use of ubiquitous objects for radiation dosimetry is preferred because the affected persons in such unexpected events are usually not covered by personal dosimetry services and do not carry personal dosimeters. Often accident sites do not have area monitoring system in place. As the main concern of the dosimetry is health effects, a quick distinction of level of exposures of the affected persons for the required medical care becomes important in all accidents involving radiation. Both in large scale nuclear accidents such Fukushima, Chernobyl or Hiroshima and Nagasaki where large population around the accident site get exposed to radiation (evacuation is based on doses) and in smaller but panicky events, such as misuse of radiological exposure device (RED), radiological dispersive device (RDD: 'Dirty Bomb'), improvised nuclear device (IND) and deliberate dispersal of radioactive contaminants, a need for an ubiquitous personal dosimeter is well recognized. As biological dosimetry systems are yet to become viable for measurements of doses with required accuracy and speed, use of physical dosimeters is often explored. Among the various types of physical dosimetry systems, use of TL and OSL by processing common material such as bricks or tiles and measuring the doses cumulated for long periods of time has already become an accepted tool for large scale nuclear accidents such as Hiroshima and Nagasaki or Chernobyl involving higher doses. In the other potential cases of unexpected situations where the doses encountered could be much lower (even to escape the range of remotely installed area monitors), the need to measure even the low doses in shortest possible time becomes important. It is often realized that in such situations, the main problem could become the panic at the work place

  15. Study of the OSL response of the CaF2:Dy (TLD-200) dosimeter

    International Nuclear Information System (INIS)

    Medeiros, Beatriz M.; Alencar, Marcus A.V. de

    2013-01-01

    The OSL dosimetry has become, in recent years, a successful technique in personal and environmental dosimetry due to high luminescence efficiency, excellent reproducibility, fast readout of signal and repeated and successive OSL measurements of the same dosimeter. Another factor that contributes to the increased use of OSL dosimetry is the use of the aluminum oxide doped with carbon (Al 2 O 3 :C) as dosimeter. Developed initially as thermoluminescent dosimeter, the Al 2 O 3 :C has an excellent OSL sensitivity, high efficiency, good linearity, low or no fading and excellent stability with respect to environmental conditions. However, the OSL dose response for aluminum oxide is linear only for low doses. For intermediate doses (doses in radiotherapy), the response is supralinear. For the values of high doses used in the processes of food irradiation and sterilization of surgical materials, the OSL signal of the aluminum oxide already saturated. Furthermore, the degree of supralinearity and the saturation value vary from sample to sample (∼ 30-300 Gy). Therefore, the use of aluminum oxide as OSL dosimeter is inappropriate in radiotherapy and in the irradiation industrial processes. The objective of this work is the study of the OSL properties of other dosimetric materials irradiated with values of intermediate and high dose to verify the applicability of the OSL dosimetry in radiotherapy and in the processes of food irradiation and sterilization of medical materials. The dosimetric material used in this work is the calcium fluoride doped with dysprosium (CaF 2 :Dy) produced by Harshaw and known commercially as TLD-200. The results demonstrate that the CaF 2 :Dy has OSL signal and the OSL dose response is linear in the range of 10 Gy to 300 Gy. Therefore, the dosimetry OSL with this dosimeter can be used in the evaluation of doses of the order of dozens to hundreds of grays. (author)

  16. Lake-level fluctuations since the Last Glaciation in Selin Co (lake), Central Tibet, investigated using optically stimulated luminescence dating of beach ridges

    International Nuclear Information System (INIS)

    Li Dewen; Li Yingkui; Ma Baoqi; Zhao, Junxiang; Dong Guocheng; Wang Liqiang

    2009-01-01

    This paper presents a preliminary study on lake-level fluctuations since the Last Glaciation in Selin Co (lake), Central Tibet, by dating four groups of beach ridges using optically stimulated luminescence (OSL). The highest/oldest beach ridge group (>100 m higher than the current lake level) is dated back to 67.9 ± 2.4 ka BP, corresponding to the early stage of the Last Glaciation (marine isotope stage (MIS) 4). This date further supports that no plateau-scale ice sheet covered the Tibetan Plateau during the Last Glaciation. The other three groups produce OSL ages of 30.4 ± 2.9 to 18.6 ± 1.7, 12.5 ± 1.6 to 9.2 ± 0.5, and 6.9 ± 0.2 ka BP respectively, most likely corresponding to cold or wet climate periods of the late stage of the Last Glaciation (MIS 2), deglaciation, and Holocene Hypsithermal. On the plateau scale, these four beach ridge groups are almost synchronous with advances or standstills of Himalayan glaciers, indicating similar climate controls across the central and southern Tibetan Plateau, and being consistent with the conclusion, obtained from nearby ice core records, that this area is affected by the South Asia monsoon. Furthermore, beach ridges are also synchronous with fluvial terraces in the northern Tibetan Plateau, implying common driving forces during their formation. Therefore, some terraces may be formed as a result of climate events rather than being of tectonic origin.

  17. Optical dating of perennially frozen deposits associated with preserved ancient plant and animal DNA in north-central Siberia

    DEFF Research Database (Denmark)

    Arnold, L.J.; Roberts, R.G.; Macphee, R.D.E.

    2008-01-01

    We present chronological constraints on a suite of permanently frozen fluvial deposits which contain ancient DNA (aDNA) from the Taimyr Peninsula of north-central Siberia. The luminescence phenomenology of these samples is first discussed, focusing on the optically stimulated luminescence (OSL) d...... of providing a reliable chronometric framework for sedimentary aDNA records in permafrost environments. (C) 2007 Elsevier Ltd. All rights reserved Udgivelsesdato: 2008...

  18. De determination for young samples using the standardised OSL response of coarse-grain quartz

    International Nuclear Information System (INIS)

    Burbidge, C.I.; Duller, G.A.T.; Roberts, H.M.

    2006-01-01

    It has recently been shown that it is possible to construct standardised curves of the sensitivity corrected growth in optically stimulated luminescence (OSL) with exposure to ionising radiation, and that they may be used in the dating of quartz and polymineral samples. Standardised growth curves are particularly advantageous where measurement time is limited, as once they have been defined, only the natural signal and the response to a subsequent test dose are required in order to determine the equivalent dose of a sub-sample. The present study is concerned with the application of the standardised growth curve approach to OSL dating of Holocene age samples. Systematic changes in the shape of the standardised growth curve of coarse-grain quartz are identified as the size of the test dose is varied, because of non-proportionality between the test dose and the luminescence test response. The effect is characterised by fitting the change in gradient of the standardised growth curve as test dose is varied. An equation is defined to describe standardised growth as a function of regenerative dose and test dose. Regenerative dose responses of other samples in this study are treated as unknowns and recovered through different growth curves to compare precision and accuracy of various methods of D e determination. The standardised growth curve is found to yield similar precision to conventional fits of single aliquot regenerative data, but slightly poorer accuracy. The standardised growth curve approach was refined by incorporating the measurement of one regenerative response for each aliquot as well as its natural signal. Measurements of this additional data point for aliquots of 22 samples were used to adjust the standardised growth equation, improving its accuracy. The incorporation of this additional data point also indicated a systematic uncertainty of 2.4% in the estimates of D e

  19. Establishment of a dosimetry method for the exposure evaluation to the ultraviolet radiation

    International Nuclear Information System (INIS)

    Gronchi, Claudia Carla

    2009-01-01

    A dosimetric method for the exposure evaluation to ultraviolet radiation was established with Al 2 O 3 :C InLight detectors and an OSL microStar reader and software, of Landauer, associated to the techniques of Optically Stimulated Luminescence (OSL) and Photo transferred Optically Stimulated Luminescence (PTOSL). The main phases of this work were: characterization of the Al 2 O 3 :C InLight detectors, without pre-conditioning, exposed to ultraviolet radiation (RUV) of solar and artificial sources, using the OSL technique; characterization of the Al 2 O 3 :C InLight detectors, pre-conditioned, exposed to RUV solar and artificial sources, using the PTOSL technique; practical applications of the Al 2 O 3 :C InLight detectors to the solar and artificial RUV, originating from TIG (Tungsten Inert Gas) and electric welding. The Al 2 O 3 :C InLight detectors presented satisfactory OSL and PTOSL responses in relation to the parameters: wavelength, UV illumination time, irradiance, radiance exposure and angular dependence to the RUV. Those detectors presented maximum OSL and PTOSL stimulation for the wavelength of 330 nm, showing that they are may be useful for UVA radiation detection and dosimetry. (author)

  20. A Radiation Dosimetry Method Using Pulsed Optically Stimulated Luminescence

    International Nuclear Information System (INIS)

    Akselrod, M.S.; McKeever, S.W.S.

    1999-01-01

    A method for the determination of absorbed radiation dose is described based on pulsed optically stimulated luminescence (POSL). The method relies upon the stimulation of an irradiated sample with a train of light pulses from a suitable light source (e.g. a laser) using a wavelength which is within the range of wavelengths corresponding to the radiation-induced optical absorption in the irradiated sample. The subsequent emitted light, due to the detrapping of trapped charges and their subsequent recombination with charge of the opposite sign, is synchronously detected in the period between each stimulation pulse. The total luminescence is summed over the desired number of stimulation pulses and this forms the measured POSL signal. By monitoring the emitted light only in the period between stimulation pulses one can reduce the optical filtering required to discriminate between the stimulation light and the emission light; in this way a high measurement efficiency, and, therefore, a high radiation sensitivity (luminescence intensity per unit absorbed dose) is achieved. Key parameters in the method are the intrinsic luminescence lifetime for the material being used as the luminescent detector, the width of the optical stimulation pulse, and the period between pulses. For optimum operation the measurement parameters should be such that both the pulse width and the time between pulses are much less than the luminescence lifetime. By appropriate choice of the power of the optical stimulation, the frequency of the stimulation pulses, and the total stimulation period, one can also re-measure the absorbed dose several times. In this way, a re-read capability is available with the procedure. The method is illustrated using light from a 2nd-harmonic Nd:YAG laser, with irradiated, anion-deficient aluminium oxide as the luminescent detector material. (author)

  1. The influence of radiation-induced defects on thermoluminescence and optically stimulated luminescence of α-Al_2O_3:C

    International Nuclear Information System (INIS)

    Nyirenda, A.N.; Chithambo, M.L.

    2017-01-01

    It is known that when α-Al_2O_3:C is exposed to excessive amounts of ionising radiation, defects are induced within its matrix. We report the influence of radiation-induced defects on the thermoluminescence (TL) and optically stimulated luminescence (OSL) measured from α-Al_2O_3:C after irradiation to 1000 Gy. These radiation-induced defects are thermally unstable in the region 450–650 °C and result in TL peaks in this range when the TL is measured at 1 °C/s. Heating a sample to 700 °C obliterates the radiation-induced defects, that is, the TL peaks corresponding to the radiation induced defects are no longer observed in the subsequent TL measurements when moderate irradiation doses below 10 Gy are used. The charge traps associated with these radiation-induced defects are more stable than the dosimetric trap when the sample is exposed to either sunlight or 470-nm blue light from LEDs. TL glow curves measured following the defect-inducing irradiation produce a dosimetric peak that is broader and positioned at a higher temperature than observed in glow curves obtained before the heavy irradiation. In addition, sample sensitization/desensitization occurs due to the presence of these radiation-induced defects. Furthermore, both the activation energy and the kinetic order of the dosimetric peak evaluated when the radiation-induced defects are present in the sample are significantly lower in value than those obtained when these defects are absent. The radiation-induced defects also affect the shape and total light sum of the OSL signal as well as the position and width of the resultant residual phototransferred thermoluminescence main peak.

  2. Angular dependence of the nanoDot OSL dosimeter

    International Nuclear Information System (INIS)

    Kerns, James R.; Kry, Stephen F.; Sahoo, Narayan; Followill, David S.; Ibbott, Geoffrey S.

    2011-01-01

    Purpose: Optically stimulated luminescent detectors (OSLDs) are quickly gaining popularity as passive dosimeters, with applications in medicine for linac output calibration verification, brachytherapy source verification, treatment plan quality assurance, and clinical dose measurements. With such wide applications, these dosimeters must be characterized for numerous factors affecting their response. The most abundant commercial OSLD is the InLight/OSL system from Landauer, Inc. The purpose of this study was to examine the angular dependence of the nanoDot dosimeter, which is part of the InLight system. Methods: Relative dosimeter response data were taken at several angles in 6 and 18 MV photon beams, as well as a clinical proton beam. These measurements were done within a phantom at a depth beyond the build-up region. To verify the observed angular dependence, additional measurements were conducted as well as Monte Carlo simulations in MCNPX. Results: When irradiated with the incident photon beams parallel to the plane of the dosimeter, the nanoDot response was 4% lower at 6 MV and 3% lower at 18 MV than the response when irradiated with the incident beam normal to the plane of the dosimeter. Monte Carlo simulations at 6 MV showed similar results to the experimental values. Examination of the results in Monte Carlo suggests the cause as partial volume irradiation. In a clinical proton beam, no angular dependence was found. Conclusions: A nontrivial angular response of this OSLD was observed in photon beams. This factor may need to be accounted for when evaluating doses from photon beams incident from a variety of directions.

  3. A CaS : Ce, Sm-based dosimeter for online dosimetry measurement

    International Nuclear Information System (INIS)

    Sun Yurun; Chen Zhaoyang; Fan Yanwei; Yan Shiyou; He Chengfa

    2011-01-01

    A film dosimeter based on optically stimulated luminescence (OSL) material of CaS : Ce, Sm was developed for online irradiation dosimetry measurement. The stimulation is provided by a laser with a wavelength of 980 nm, and the OSL luminescence is collected by a photodiode. Using 60 Co γ-rays, we investigated the dosimetry characteristic of the dosimeter at different dose rates and total doses. The real-time detection results showed that the OSL signals versus total ionizing dose exhibited a good linearity in a dose range of 0.1-185 Gy. (authors)

  4. Real-time luminescence from Al2O3 fiber dosimeters

    International Nuclear Information System (INIS)

    Polf, J.C.; Yukihara, E.G.; Akselrod, M.S.; McKeever, S.W.S.

    2004-01-01

    The real-time luminescence signal from Al 2 O 3 single crystal fibers, monitored during simultaneous irradiation and optical stimulation, was investigated using computer simulations and experimental measurements. Both radioluminescence (RL) and optically stimulated luminescence (OSL) signals were studied. The simulations were performed initially using a simple one-trap/one-recombination-center energy band model, and then extended to include shallow and deep electron traps as well. Real-time luminescence experiments were performed for different radiation dose rates and optical stimulation powers using periodic laser stimulation of the samples through a fiber optic cable, and the experimental results were compared with the predictions from the computer simulations. The luminescence signal was observed, both theoretically and experimentally, to increase from its initial value to a steady-state level. The steady-state RL and OSL levels were found to be dependent on dose rate, the steady-state level of the real-time OSL being independent of laser power. It was also shown that the total integrated absorbed dose throughout the irradiation period can be determined by correcting the real-time OSL signal for depletion caused by each laser stimulation pulse. The effects of the shallow and deep traps on the time-dependence of the real-time luminescence signal were studied comparing the experimental data from several Al 2 O 3 fibers known to have different trapping state concentrations. The additional traps were found to slow the response of the real-time luminescence such that the time to reach steady state was increased as the additional traps were added

  5. Establishing a luminescence chronology for a palaeosol-loess profile at Tokaj (Hungary): A comparison of quartz OSL and polymineral IRSL signals

    DEFF Research Database (Denmark)

    Schatz, Ann-Kathrin; Buylaert, Jan-Pieter; Murray, Andrew

    2012-01-01

    We present a comparative study of quartz OSL, polymineral IRSL at low temperature (50 °C, IR50) and post-IR elevated temperature (290 °C) IRSL (pIRIR290) feldspar dating on nine samples from the Tokaj loess section in NE Hungary (SE Europe). Preheat plateau tests show a drop in quartz OSL De...... between 160 and 240 °C but above 240 °C a clear De plateau is present. Quartz OSL SAR is shown to be generally appropriate to these samples (recycling, recuperation) but a satisfactory dose recovery result was only obtained when a dose was added to a sample without any prior optical or thermal pre...... of the Tokaj loess has been deposited during MIS 3 (60–24 ka), with periods of soil formation occurring during the onset of MIS 3 (≥58 ka) and between about 35 and 25 ka. Our results also indicate episodic deposition of loess and varying, non-linear sedimentation rates during MIS 3. Proxy analyses...

  6. Natural and laboratory OSL growth curve–Verification of the basic assumption of luminescence dating

    International Nuclear Information System (INIS)

    Kijek, N.; Chruścińska, A.

    2016-01-01

    The basic assumption of luminescence dating is the equality between the growth curve of OSL generated by the natural radiation and the OSL growth curve reconstructed in laboratory conditions. The dose rates that generate the OSL in nature and in laboratory experiments differ by about ten orders of magnitude. Recently some discrepancies between the natural and laboratory growth curves have been observed. It is important to establish their reasons in order to introduce appropriate correction into the OSL dating protocol or to find a test that allows to eliminate the samples which should not be used for dating. For this purpose, both growth curves, natural and laboratory, were reconstructed by means of computer simulations of the processes occurring in the sample during its deposition time in environment as well as those which occur in a laboratory during dating procedure. The simulations were carried out for three models including one shallow trap, two OSL traps, one disconnected deep and one luminescence center. The OSL model for quartz can be more complex than the one used in the presented simulations, but in spite of that the results show effects of growth curves discrepancies similar to those observed in experiments. It is clear that the consistency of growth curves is not a general feature of the OSL processes, but rather a result of an advantageous configuration of trap parameters. The deep disconnected traps play the key role and their complete filling before the zeroing of OSL signal is a necessary condition of the growth curves' consistency. - Highlights: • Process of OSL growth curve generation in nature and in laboratory was simulated. • Discrepancies between the natural and the laboratory growth curves are observed. • Deep disconnected traps play the key role in growth curve inequality. • Empty deep traps before zeroing of OSL cause the inequality of growth curves.

  7. New data on OSL dating of Early Khalynian deposits of Northern Caspian

    Science.gov (United States)

    Sychev, Nikita; Yanina, Tamara; Svitoch, Alexander; Kurbanov, Redzhep; Badyukova, Ekaterina

    2016-04-01

    Ponto-Caspian region is the key region the study of which can provide information about the paleogeographic history of the central Eurasia, particularly revealing the history of the East European Plain, the Caucasus and Central Asia. However, despite the long history of the study, today there is no accepted general stratigraphic scheme of the Caspian Sea. One of the most interesting and important stages of Late Pleistocene history of Caspian is Khalynian transgression which is divided into two major phases: early and ate. In the Caspian lowland Lower Khalynian stage are represented by a unique type of deposit - "chocolate clays". A distinctive feature of these sediments is widely distributed among Lower Khalynian deposits of Northern Caspian and the Volga region. All clay deposits are confined to the diverse origins of depression before-Khalynian relief. Chocolate clays formation consists of facies: mono-clay (typological), layered, sand- and silty-clay (Svitoch, Yanina, 1997). Determining the age of chocolate clays by optically stimulated luminescence (OSL) in our view will allow bettering the understanding of their genesis. Age of chocolate clays of Lower Volga was widely dated using the radiocarbon. However, the existing chronology is controversial, raises a number of issues, primarily due to the material of which are used for dating - thin shells of Caspian mollusks of the Didacna Eichw. genus, which are characterized by a significant isotopic exchange with the enclosing sediments (Arslanov, 2015). Lower Volga region is characterized by very complex geological structure of the Late Pleistocene deposits (alternating continental aeolian, alluvial and slope sediments with marine Caspian deposits of different age). There are many conflicting opinions, not only with respect to paleogeographic features of the area, but also to its precise chronology. The differences in opinion over the age of the individual stages of development of the Caspian Sea (transgressions and

  8. Characterization of optically stimulated luminescence for assessment of breast doses in mammography screening

    International Nuclear Information System (INIS)

    Alothmany, N.; Jiman, A.; Molla, N.I.; Natto, H.; Tayeb, M.; Nadwi, F.; Yusuf, M.; Alothmany, D.; Kinsara, A.A.; Saoudi, A.; Mail, N.; Khafaji, M.A.

    2016-01-01

    Landauer optically stimulated luminescence (OSL) technology nanoDot dosimeters (OSLDs) are characterized for use in mammography screening at various tube voltages, mAs values and target/filter combinations. The average glandular dose (AGD) for a 50-mm breast, based on the representative compressed breast thickness of a 45-mm polymethyl methacrylate (PMMA) phantom, is assessed using OSLDs with different beam conditions. Further, the linearity of the OSLD response is measured and angular dependence tests are performed for various tube potentials, mAs and target/filter combinations. The breast-absorbed doses are measured at various depths for a 32-kVp X-ray beam at 100 mAs, with a Mo/Rh target/filter combination. The measured incident air kerma values at different lateral positions exhibit a maximum deviation of 6%, and the average relative response of the OSLDs at the reference point (center) with respect to various lateral positions is found to be 1.001 ± 0.09%. The calculated AGD values are in the 1.3 ± 0.1-3.5 ± 0.2 mGy range, depending on the tube potential, tube loading and target/filter combinations. An exposure setup featuring the auto-exposure control (AEC) mode, 28 kVp, 73.8 mAs, and a Mo/Rh target/filter combination may be preferred for mammography screening for a compressed breast thickness of 45 mm. (authors)

  9. Effects of temperature and ionization density in medical luminescence dosimetry using Al{sub 2}O{sub 3}:C

    Energy Technology Data Exchange (ETDEWEB)

    Morgenthaler Edmund, J.

    2007-11-15

    A new system containing small crystals of aluminum oxide doped with carbon (Al{sub 2}O{sub 3}:C) attached to optical fiber cables has recently been introduced. During irradiation, the system monitors the radioluminescence (RL)from the crystals and after irradiation, an optically stimulated luminescence (OSL) signal can be read out by stimulating the crystal with light. This thesis applies the initial part and the total area of the resulting OSL decay curve for dosimetry measurements and investigates the effects of temperature and proton energy, i.e. ionization density, on the RL and OSL signals from Al{sub 2}O{sub 3}:C. In the temperature study, it was found that the OSL signal depends on both irradiation and stimulation temperature while the RL signal is effected only by the irradiation temperature. The initial OSL signal is increasing with temperature whereas the total OSL area is decreasing. Therefore, if the irradiation temperature is kept constant, one can find an integration time which provides an OSL signal independent of stimulation temperature. Overall, the RL and OSL signals vary between -0.2 to 0.6% per C. Thermal effects were simulated with a band structure model and indicated that the temperature effects are caused by the combined efforts of energetic shallow traps and thermal excitation from intermediate states in deeper traps. In the study of ionization density, we investigated protons with energies between 10 and 60 MeV (4.57 to 1.08 keV/mum in water). Experimentally, we observed that the initial OSL signalprovided a signal independent of linear energy transfer (LET) for allenergies at 0.3 Gy. The total OSL area showed an LET dependent behavior atall doses and energies. We used track structure theory (TST) to give possible explanations for the LET dependence of the OSL signal. From these calculations, we found that the initial OSL signal is, in general, not LET independent which makes Al2O3:C unsuitable for OSL proton dosimetry. The initial OSL

  10. Effects of temperature and ionization density in medical luminescence dosimetry using Al2O3:C

    International Nuclear Information System (INIS)

    Morgenthaler Edmund, J.

    2007-11-01

    A new system containing small crystals of aluminum oxide doped with carbon (Al 2 O 3 :C) attached to optical fiber cables has recently been introduced. During irradiation, the system monitors the radioluminescence (RL)from the crystals and after irradiation, an optically stimulated luminescence (OSL) signal can be read out by stimulating the crystal with light. This thesis applies the initial part and the total area of the resulting OSL decay curve for dosimetry measurements and investigates the effects of temperature and proton energy, i.e. ionization density, on the RL and OSL signals from Al 2 O 3 :C. In the temperature study, it was found that the OSL signal depends on both irradiation and stimulation temperature while the RL signal is effected only by the irradiation temperature. The initial OSL signal is increasing with temperature whereas the total OSL area is decreasing. Therefore, if the irradiation temperature is kept constant, one can find an integration time which provides an OSL signal independent of stimulation temperature. Overall, the RL and OSL signals vary between -0.2 to 0.6% per C. Thermal effects were simulated with a band structure model and indicated that the temperature effects are caused by the combined efforts of energetic shallow traps and thermal excitation from intermediate states in deeper traps. In the study of ionization density, we investigated protons with energies between 10 and 60 MeV (4.57 to 1.08 keV/μm in water). Experimentally, we observed that the initial OSL signalprovided a signal independent of linear energy transfer (LET) for allenergies at 0.3 Gy. The total OSL area showed an LET dependent behavior atall doses and energies. We used track structure theory (TST) to give possible explanations for the LET dependence of the OSL signal. From these calculations, we found that the initial OSL signal is, in general, not LET independent which makes Al2O3:C unsuitable for OSL proton dosimetry. The initial OSL signal can, however

  11. Rapid and cyclic dust accumulation during MIS 2 in Central Asia inferred from loess OSL dating and grain-size analysis.

    Science.gov (United States)

    Li, Yun; Song, Yougui; Lai, Zhongping; Han, Li; An, Zhisheng

    2016-09-02

    Due to lack of reliable proxies from the Westerlies-dominant region, the strength change of Northern Hemisphere Westerlies remains poorly understood. The aim of this study is to provide a reliable paleoclimatic proxy about the Northern Hemisphere Westerlies change. Here we report a 30.7 m thick loess section from the Ili basin directly controlled by the Westerlies. Based on optically stimulated luminescence (OSL) and high resolution grain-size records, we reconstruct the change history of the Westerlies strength during the last glacial period (mainly Marine Isotope Stages 2, MIS2), being similar with the Westerlies index recorded in the Qinghai Lake sediments. Within error limits, all ages are in stratigraphic order. We further compare the climatic records among the Ili loess, Qinghai Lake and the NGRIP, their similarity shows a good climatic coupling relationship among the Central Asia, East Asia and the North Atlantic, and the Westerlies plays a critical influence in transporting the North Atlantic signal to Central and East Asia.

  12. Radiocromic film, TLD, OSL and 'Paracas Phantom' by dosimetric intercomparation in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Paucar Jauregui, R.; Condori Marcos, P.; Vidarte Garcia, F.

    2008-01-01

    Full text: In Peru, one deals to patients with arteriovenous malformations or cerebral tumors by means of stereotactic radiosurgery, using fine photon beams of high energy of 6 MeV, generated by a linear accelerator Varian 2100 Clinac CD of the Complejo Hospitalario San Pablo in Lima, Peru. In this work we describes the 'Dosimetric Intercomparation System of the Quality Assurance Program in Stereotactic Radiosurgery of the Complejo Hospitalario San Pablo (DIS)'. The DIS allows to guarantee application of the doses with high accuracy. It shows the good performance of the Local DIS's components: dosimetry of radiocromics films, dosimetry termoluminiscent (TLD), dosimetry of optically stimulated luminescence (OSL) and an anthropomorphic phantom of head constructed locally, denominated 'Paracas Phantom'. Also, in the International DIS practiced with The University of Texas Md Anderson Cancer Center, stands out results within the ranges: a) Dose to the center of the target (RDS/Institution): 0,95-1,05; b) Treated volumen (Measured/Institution): 0,75 - 1,05; c) Ratio of measure treated volume to target volume: 1,00 - 2,00; and d) Minimum dose to target (Minimum dose/Prescription dose): >0,90. It concludes that the DIS is important for the good decision making on the radiological safety of the patients dealt with stereotactic radiosurgery. (author)

  13. OSL Age Determination of the Hearths in a Bronze Age Dwelling Site by using Bayesian Statistics

    International Nuclear Information System (INIS)

    Kim, Myung Jin; Yang, Hye Jin; Hong, Duk Geun

    2011-01-01

    OSL dating for three hearths having the sequence of use and discard in No. 29 and 29-1 dwelling sites at Sogol cultural site was carried out. Resulting from the deconvolution of natural CW-OSL decay curve and thermal zeroing test, it was turned out that OSL signal was entirely composed of the heat- and light-sensitive fast component with high photoionization cross-section and all quartz OSL signals were thermally bleached under 300 .deg. C which is the minimum temperature related to heating and cooking in Bronze age. After dose recovery test and plateau test, paleodose of each hearth sample was evaluated by using SAR method, and OSL age was determined from the ratio of paleodose to annual dose rate. For the purpose of the precision improvement of OSL age, Bayesian statistics was applied to each hearth's age and the archaeological sequence information. Finally, it could be concluded to the accurate use period of each hearth from the resultant OSL ages

  14. OSL Age Determination of the Hearths in a Bronze Age Dwelling Site by using Bayesian Statistics

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Jin [Neosiskorea Co. Ltd., Seoul (Korea, Republic of); Yang, Hye Jin [Baekje Cultural Properties Research Institute, Gongju (Korea, Republic of); Hong, Duk Geun [Kangwon National University, Chuncheon (Korea, Republic of)

    2011-06-15

    OSL dating for three hearths having the sequence of use and discard in No. 29 and 29-1 dwelling sites at Sogol cultural site was carried out. Resulting from the deconvolution of natural CW-OSL decay curve and thermal zeroing test, it was turned out that OSL signal was entirely composed of the heat- and light-sensitive fast component with high photoionization cross-section and all quartz OSL signals were thermally bleached under 300 .deg. C which is the minimum temperature related to heating and cooking in Bronze age. After dose recovery test and plateau test, paleodose of each hearth sample was evaluated by using SAR method, and OSL age was determined from the ratio of paleodose to annual dose rate. For the purpose of the precision improvement of OSL age, Bayesian statistics was applied to each hearth's age and the archaeological sequence information. Finally, it could be concluded to the accurate use period of each hearth from the resultant OSL ages.

  15. A new method for measuring bioturbation rates in sandy tidal flat sediments based on luminescence dating

    DEFF Research Database (Denmark)

    Madsen, Anni T.; Murray, Andrew S.; Jain, Mayank

    2011-01-01

    The rates of post-depositional mixing by bioturbation have been investigated using Optically Stimulated Luminescence (OSL) dating in two sediment cores (BAL2 and BAL5), retrieved from a sandy tidal flat in the Danish part of the Wadden Sea. A high-resolution chronology, consisting of thirty-six OSL...

  16. A listing of cosmogenic, optically-stimulated-luminescence, (U-Th)/He, and fission-track sample locations, analyses, and age data compiled as part of Marsden contract GNS002 (2000-2004) : subduction initiation beneath Fiordland, southwest New Zealand

    International Nuclear Information System (INIS)

    Sutherland, R.

    2007-01-01

    This report is an archive of data relevant to Fiordland tectonic evolution. Specifically these are the data that were collected and compiled as part of Marsden contract GNS002 (2000-2004); samples were collected between 1987 and 2002. The principal investigator of the Marsden Fund project was Rupert Sutherland (GNS Science). Additional named investigators (with responsibilities and affiliations) were: Kyeong Kim (cosmogenic isotope dating; GNS Science); Peter Kamp (fission track dating; Waikato University); Martha House (U-Th/He dating; Caltech, USA); and Michael Gurnis (numerical models of subduction initiation; Caltech, USA). After the project began, Uwe Rieser from Victoria University agreed to undertake optically-stimulated luminescence (OSL) dating as part of the project. (author). 6 refs

  17. The influence of radiation-induced defects on thermoluminescence and optically stimulated luminescence of α-Al{sub 2}O{sub 3}:C

    Energy Technology Data Exchange (ETDEWEB)

    Nyirenda, A.N., E-mail: anyirenda@gmail.com; Chithambo, M.L.

    2017-04-15

    It is known that when α-Al{sub 2}O{sub 3}:C is exposed to excessive amounts of ionising radiation, defects are induced within its matrix. We report the influence of radiation-induced defects on the thermoluminescence (TL) and optically stimulated luminescence (OSL) measured from α-Al{sub 2}O{sub 3}:C after irradiation to 1000 Gy. These radiation-induced defects are thermally unstable in the region 450–650 °C and result in TL peaks in this range when the TL is measured at 1 °C/s. Heating a sample to 700 °C obliterates the radiation-induced defects, that is, the TL peaks corresponding to the radiation induced defects are no longer observed in the subsequent TL measurements when moderate irradiation doses below 10 Gy are used. The charge traps associated with these radiation-induced defects are more stable than the dosimetric trap when the sample is exposed to either sunlight or 470-nm blue light from LEDs. TL glow curves measured following the defect-inducing irradiation produce a dosimetric peak that is broader and positioned at a higher temperature than observed in glow curves obtained before the heavy irradiation. In addition, sample sensitization/desensitization occurs due to the presence of these radiation-induced defects. Furthermore, both the activation energy and the kinetic order of the dosimetric peak evaluated when the radiation-induced defects are present in the sample are significantly lower in value than those obtained when these defects are absent. The radiation-induced defects also affect the shape and total light sum of the OSL signal as well as the position and width of the resultant residual phototransferred thermoluminescence main peak.

  18. Thermo-optical properties of optically stimulated luminescence in feldspars

    DEFF Research Database (Denmark)

    Poolton, N.R.J.; Bøtter-Jensen, L.; Johnsen, O.

    1995-01-01

    Optically stimulated luminescence processes in feldspars are subject to competing thermal enhancement and quenching processes: this article describes the thermal enhancement effects for orthoclase, albite and plagioclase feldspars. It is demonstrated that certain lattice vibrational modes can be ...

  19. High resolution OSL and post-IR IRSL dating of the last interglacialeglacial cycle at the Sanbahuo loess site (northeastern China)

    DEFF Research Database (Denmark)

    Yi, Shuangwen; Buylaert, Jan-Pieter; Murray, Andrew

    2015-01-01

    Northeastern China is located in the East Asian monsoon region; it is sensitive to both high and low latitude global climate systems. Loess deposits in the region have considerable potential as sensitive archives of past climate changes. However, research into loess deposition and climate change...... to have been a period of fast loess deposition at ~62 ka, perhaps indicative of winter monsoon intensification with a very cold and dry climate that lead to a serious desertification of dunefields in northeastern China. © 2015 Elsevier B.V. All rights reserved....... in this region is restricted by the lack of independent age control. In this study, coarse-grained quartz SAR OSL and K-feldspar post-IR infrared (IR) stimulated luminescence (post-IR IRSL; pIRIR290) methods have been used to date the Sanbahuo loess site in northeastern China. The quartz OSL characteristics...

  20. Bioactivity characterization of 45S5 bioglass using TL, OSL and EPR: Comparison with the case of 58S sol-gel bioactive glass

    Energy Technology Data Exchange (ETDEWEB)

    Polymeris, G.S., E-mail: gspolymeris@ankara.edu.tr [Ankara University, Institute of Nuclear Sciences, 06100 Beşevler, Ankara (Turkey); Giannoulatou, V. [Ankara University, Institute of Nuclear Sciences, 06100 Beşevler, Ankara (Turkey); Solid State Section, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Kyriakidou, A. [Solid State Section, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Sfampa, I.K. [Nuclear Physics Laboratory, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Theodorou, G.S. [Solid State Section, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Şahiner, E.; Meriç, N. [Ankara University, Institute of Nuclear Sciences, 06100 Beşevler, Ankara (Turkey); Kitis, G. [Nuclear Physics Laboratory, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Paraskevopoulos, K.M. [Solid State Section, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece)

    2017-01-01

    The current work exploits the effective application of thermoluminescence (TL), optically stimulated luminescence (OSL) and the possibility of applying Electron Paramagnetic Resonance (EPR) for the discrimination between different bioactive responses in the case of the 45S5 bioactive glass (SiO{sub 2} 45, Na{sub 2}O 24.5, CaO 24.5, P{sub 2}O{sub 5} 6 in wt%), which was synthesized through melting process. These techniques are suggested mainly due to their low spectroscopic detection thresholds. The original 45S5 in grain size range of 20–40 μm was immersed in the Simulated Body Fluid (SBF) for various different immersion times ranging over one week. In this work the 110 °C TL peak, a specific OSL component and the EPR signal at g = 2.013 ascribed to oxygen hole center (OHC) are used due to their sensitivity to the different bioactive responses. For all luminescence and EPR components, the intensity plot versus immersion time yields sharp discontinuities, resulting in effective probes regarding the timescale for both the beginning as well as the end of the procedure of the crystalline HCAp formation respectively. On the contrary to the smooth decreasing pattern of both luminescence entities, the peak to peak amplitude of the EPR signal indicates an initial increase for the initial 16 min of immersion, followed by a further decrease throughout the immersion time duration. The discontinuities monitored for both sensitivity of TL, OSL and EPR, in conjunction with the discontinuities monitored for the sensitization of TL and OSL, when plotted versus immersion time, provide an individual time scale for each one of the chemical reactions involved in the five steps of the aforementioned procedure. According to the authors' best knowledge, scarce characterization techniques could provide this time scale frame, while it is the first time that such an application of OSL and EPR is attempted. Finally, the bioactive response of the 45S5 bioglass was compared with that

  1. The analysis of time-resolved optically stimulated luminescence: I. Theoretical considerations

    International Nuclear Information System (INIS)

    Chithambo, M L

    2007-01-01

    This is the first of two linked papers on the analysis of time-resolved optically stimulated luminescence. This paper focusses on a theoretical basis of analytical methods and on methods for interpretation of time-resolved luminescence spectra and calculation of luminescence throughput. Using a comparative analysis of the principal features of time-resolved luminescence and relevant analogues from steady state optical stimulation, formulae for configuring a measurement system for optimum performance are presented. We also examine the possible use of stretched-exponential functions for analysis of time-resolved optically stimulated luminescence spectra

  2. General radiographic attributes of optically stimulated luminescence dosimeters: A basic insight

    Science.gov (United States)

    Musa, Y.; Hashim, S.; Ghoshal, S. K.; Bradley, D. A.; Ahmad, N. E.; Karim, M. K. A.; Hashim, A.; Kadir, A. B. A.

    2018-06-01

    We report the ubiquitous radiographic characteristics of optically stimulated luminescence dosimeters (OSLD) so called nanoDot OSLDs (Landauer Inc., Glendwood, IL). The X-ray irradiations were performed in free air ambiance to inspect the repeatability, the reproducibility, the signal depletion, the element correction factors (ECFs), the dose response and the energy dependence. Repeatability of multiple readouts after single irradiation to 10 mGy revealed a coefficient of variation below 3%, while the reproducibility in repeated irradiation-readout-annealing cycles was above 2%. The OSL signal depletion for three nanoDots with simultaneous irradiation to 20 mGy and sequential readouts of 25 times displayed a consistent signal reduction ≈0.5% per readout with R2 values over 0.98. ECFs for individual OSLDs were varied from 0.97 to 1.03. In the entire dose range under 80 kV, a good linearity with an R2 exceeding 0.99 was achieved. Besides, the percentage difference between OSLD and ion-chamber dose was less than 5%, which was superior to TLD. The X-ray photon irradiated energy response factors (between 0.76 and 1.12) in the range of 40-150 kV (26.1-61.2 keV) exhibited significant energy dependence. Indeed, the nanoDot OSLDs disclosed good repeatability, reproducibility and linearity. The OSLDs measured doses were closer to ion-chamber doses than that of TLD. It can be further improved up to ≈3% by applying the individual dosimeter ECF. On top, the energy dependent uncertainties can be minimized using the energy correction factors. It is established that the studied nanoDot OSLDs are prospective for measuring entrance dose in general radiographic practices.

  3. Thermal dependence of time-resolved blue light stimulated luminescence in α-Al2O3:C

    DEFF Research Database (Denmark)

    Pagonis, Vasilis; Ankjærgaard, Christina; Jain, Mayank

    2013-01-01

    (activation energy, Eth=0.067±0.002 eV) and thermal quenching (activation energy W=(1.032+0.005) eV). Changes in the shape of the TR-OSL curves were analyzed at different stimulation temperatures using analytical expressions available in the literature. The TR-OSL signals contain a slower temperature...

  4. Optically stimulated luminescence and thermoluminescence in CVD diamond and dosimetric evaluation in fields of ionizing radiation; Luminiscencia opticamente estimulada y termoluminiscencia en diamante DQV y evaluacion dosimetrica en campos de radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Barboza F, M.; Chernov, V.; Pedroza M, M. [Centro de Investigaciones en Fisica, Universidad de Sonora, A.P. 5-088, 83190 Hermosillo, Sonora (Mexico); Schreck, M. [Universitat Augsburg, Institut fur Physik D-86135, Augsburg (Germany); Preciado F, S.; Melendrez, R. [Universidad de Sonora, A.P. 130, 83000 Hermosillo, Sonora (Mexico)

    2006-07-01

    The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in 200-380 C being compared with those that it presents the polluted diamond with nitrogen in 80-277 C. The dosimetric behavior in the pure sample is observed lineal in two regions 0-16 Gy and in 30-100 Gy, only the doped sample didn't present linearity in the all range of the studied dose. The advantage is stood out of LOE on TL because the first one not requires of thermal stimulation in such a way that is more appropriate to detect and to measure radiation doses in biomedicine. (Author)

  5. Dosimetry of Al2O3 optically stimulated luminescent dosimeter at high energy photons and electrons

    Science.gov (United States)

    Yusof, M. F. Mohd; Joohari, N. A.; Abdullah, R.; Shukor, N. S. Abd; Kadir, A. B. Abd; Isa, N. Mohd

    2018-01-01

    The linearity of Al2O3 OSL dosimeters (OSLD) were evaluated for dosimetry works in clinical photons and electrons. The measurements were made at a reference depth of Zref according to IAEA TRS 398:2000 codes of practice at 6 and 10 MV photons and 6 and 9 MeV electrons. The measured dose was compared to the thermoluminescence dosimeters (TLD) and ionization chamber commonly used for dosimetry works for higher energy photons and electrons. The results showed that the measured dose in OSL dosimeters were in good agreement with the reported by the ionization chamber in both high energy photons and electrons. A reproducibility test also reported excellent consistency of readings with the OSL at similar energy levels. The overall results confirmed the suitability of OSL dosimeters for dosimetry works involving high energy photons and electrons in radiotherapy.

  6. OSL surface exposure dating of a lithic quarry in Tibet: Laboratory validation and application

    DEFF Research Database (Denmark)

    Gliganic, L.A.; Meyer, M.C.; Sohbati, R.

    2018-01-01

    developed OSL Surface exposure dating technique (OSL-Surf) to date flake scars at lithic quarry sites. We performed the first quantitative validation of the model describing the OSL-Surf dating technique using a controlled laboratory experiment. Our results show that longer laboratory bleaching durations......-depth profile that could be used to calibrate the model to estimate the exposure duration of a flake scar associated with human exploitation of the area. Finally, we observe that the μ parameter of the OSL-Surf model varies considerably between the laboratory-bleached and two naturally daylight-bleached...... datasets, despite having identical lithologies. We thus infer that, in addition to lithological controls, the μ parameter is primarily sensitive to the daylight irradiation geometry and only weakly dependent on spectrum of the incident light; this interpretation implies a narrow effective bleaching...

  7. Optically stimulated luminescence response to Al2O3 to beta radiation

    DEFF Research Database (Denmark)

    Akselrod, A.; Akselrod, M.S.; Agersnap Larsen, N.

    1999-01-01

    . The samples were used in two OSL readout modes: (a) cw-OSL using a tungsten lamp, and (b) pulsed-OSL using a Nd:YAG laser. Comparisons were made with TL properties, where possible. The samples were irradiated using a variety of sources, including Pm-147, Tl-204, Sr-90-Y-90 and Co-60, and under a variety...... of cover thicknesses. The response per unit H-p(0.07), normalised to Co-60, is compared for each dosemeter type and discussed within the framework of DOELAP and EU recommended limits....

  8. Radiation dosimetry by optically stimulated phosphorescence of CaF2:Mn

    International Nuclear Information System (INIS)

    Bernhardt, R.

    1974-01-01

    In addition to the light emission which occurs in TL, trapped electrons in CaF 2 :Mn can also be released by stimulation with visible and UV light. The measurement of stimulated light emission is disturbed by illumination. But there is an optically-stimulated phosphorescence, which permits to separate measurement of stimulated light emission and illumination. A theory is given. During illumination a part of the released electrons are captured by flat traps, which are emptied at room temperature. A dose dependent signal can be measured at a defined time after the stimulating pulse of visible light. Dosimeters (CaF 2 :Mn teflon disks) were illuminated by the light of a tungsten lamp. The dose response curve was found to be linear from 1 to 10 5 rads. The response curve obtained for optical stimulation was similar to the TL-response curve. Fading of the optically-stimulated signal was higher than TL-fading. Repeated readings of a single sample are possible. The number of readings is dependent on illumination conditions. Accuracy of sample to sample was about 3.5% (standard deviation). There are two background signals. (1) Post-irradiation phosphorescence occurs. Flat traps are also filled after 60 Co gamma excitation. The measurement of the signal is possible after decay of post-irradiation phosphorescence. (2) There is an optically-excited phosphorescence, which also occurs if all trapped electrons are released. The lower limit of dose measurements is given by deviations of optically-excited emission and the dark-current of the photomultiplier tube. (author)

  9. Optical stimulation of the facial nerve: a surgical tool?

    Science.gov (United States)

    Richter, Claus-Peter; Teudt, Ingo Ulrik; Nevel, Adam E.; Izzo, Agnella D.; Walsh, Joseph T., Jr.

    2008-02-01

    One sequela of skull base surgery is the iatrogenic damage to cranial nerves. Devices that stimulate nerves with electric current can assist in the nerve identification. Contemporary devices have two main limitations: (1) the physical contact of the stimulating electrode and (2) the spread of the current through the tissue. In contrast to electrical stimulation, pulsed infrared optical radiation can be used to safely and selectively stimulate neural tissue. Stimulation and screening of the nerve is possible without making physical contact. The gerbil facial nerve was irradiated with 250-μs-long pulses of 2.12 μm radiation delivered via a 600-μm-diameter optical fiber at a repetition rate of 2 Hz. Muscle action potentials were recorded with intradermal electrodes. Nerve samples were examined for possible tissue damage. Eight facial nerves were stimulated with radiant exposures between 0.71-1.77 J/cm2, resulting in compound muscle action potentials (CmAPs) that were simultaneously measured at the m. orbicularis oculi, m. levator nasolabialis, and m. orbicularis oris. Resulting CmAP amplitudes were 0.3-0.4 mV, 0.15-1.4 mV and 0.3-2.3 mV, respectively, depending on the radial location of the optical fiber and the radiant exposure. Individual nerve branches were also stimulated, resulting in CmAP amplitudes between 0.2 and 1.6 mV. Histology revealed tissue damage at radiant exposures of 2.2 J/cm2, but no apparent damage at radiant exposures of 2.0 J/cm2.

  10. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters

    International Nuclear Information System (INIS)

    Sanchez, R.M.; Vano, E.; Fernandez, J.M.; Ginjaume, M.; Duch, M.A.

    2014-01-01

    The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of 215 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was 29 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey (authors)

  11. TL and OSL studies of carbon doped magnesium aluminate (MgAl2O4:C)

    Science.gov (United States)

    Raj, Sanu S.; Mishra, D. R.; Soni, Anuj; Grover, V.; Polymeris, G. S.; Muthe, K. P.; Jha, S. K.; Tyagi, A. K.

    2016-10-01

    The MgAl2O4:C has been synthesized by using two different methods by electron gun and vacuum assisted melting of MgAl2O4 in presence of graphite. The MgAl2O4:C phosphor thus developed by these two different methods have similar types of the TL/OSL defects with multiple overlapping TL glow peaks from 100 °C to 400 °C. The Computerized Curve De-convolution Analysis (CCDA) has been used to measure TL parameters such as thermal trap depth, frequency factor and order of kinetic associated with charge transfer process in TL phenomenon. The investigated TL/OSL results show that these two methods of incorporating carbon in MgAl2O4 have generated closely resemble the defects of similar types in MgAl2O4:C lattice. However, the MgAl2O4:C synthesized by electron gun shows relatively larger concentration of the TL/OSL defects as compared to MgAl2O4:C synthesized using vacuum assisted melting method. The photo-ionization cross-section (PIC) associated with fastest OSL component of MgAl2O4: C is found to be ∼ 0.5 times than that of fastest OSL component of commercially available dosimetric grade α-Al2O3:C. The MgAl2O4:C thus developed shows good dynamic OSL dose linearity from few mGy to 1 Gy. This work reveals that MgAl2O4:C could be developed as potential tissue equivalent OSL / TL material.

  12. Tl and OSL dose response of LiF:Mg, Ti and Al{sub 2}O{sub 3}:C dosimeters using a PMMA phantom for IMRT technique quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, L. C.; Veneziani, G. R.; Campos, L. L. [Instituto de Pesquisas Energeticas e Nucleares, Gerencia de Metrologia das Radiacoes / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Sakuraba, R. K.; Cruz, J. C., E-mail: lmatsushima@usp.br [Sociedade Beneficente Israelita Brasileira - Hospital Albert Einstein, Av. Albert Einstein 627/701, Morumbi, 05652-000 Sao Paulo (Brazil)

    2014-08-15

    The principle of IMRT is to treat a patient from a number of different directions (or continuous arcs) with beams of nonuniform fluences, which have been optimized to deliver a high dose to the target volume and an acceptably low dose to the surrounding normal structures (Khan, 2010). This study intends to provide information to the physicist regarding the application of different dosimeters type, phantoms and analysis technique for Intensity Modulated Radiation Therapy (IMRT) dose distributions evaluation. The measures were performed using dosimeters of LiF:Mg,Ti and Al{sub 2}O{sub 3}:C evaluated by techniques of thermoluminescent (Tl) and Optically Stimulated Luminescence (OSL). A polymethylmethacrylate (PMMA) phantom with five cavities, two principal target volumes considered like tumours to be treated and other three cavities to measure the scattered radiation dose was developed to carried out the measures. (Author)

  13. Analysis of luminescence from common salt (NaCl) for application to retrospective dosimetry

    International Nuclear Information System (INIS)

    Spooner, N.A.; Smith, B.W.; Williams, O.M.; Creighton, D.F.; McCulloch, I.; Hunter, P.G.; Questiaux, D.G.; Prescott, J.R.

    2011-01-01

    Thermoluminescence (TL), Optically-Stimulated Luminescence (OSL) and Infrared-Stimulated Luminescence (IRSL) emitted from a set of 19 salt (NaCl) samples were studied for potential application to retrospective dosimetry. TL emission spectra revealed intense TL emissions from most samples, centred on 590 nm; UV and blue emissions were also found. Significant thermally-induced sensitivity changes were observed and TL, OSL and IRSL growth curves were measured. Pulse anneal analysis was performed, as was quantitative imaging of the TL, OSL and IRSL to assess sample heterogeneity. Kinetic analysis found lifetimes at 20 °C of the 200 °C and 240 °C TL peaks to be 0.6 ka and 4 ka respectively; sufficient for application to retrospective dosimetry.

  14. Luminescence of quartz and feldspar fingerprints provenance and correlates with the source area denudation in the Amazon River basin

    DEFF Research Database (Denmark)

    Sawakuchi, A.O.; Jain, M.; Mineli, T.D.

    2018-01-01

    The Amazon region hosts the world's largest watershed spanning from high elevation Andean terrains to lowland cratonic shield areas in tropical South America. This study explores variations in optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL) signals in suspended...... silt and riverbed sands retrieved from major Amazon rivers. These rivers drain Pre-Cambrian to Cenozoic source rocks in areas with contrasting denudation rates. In contrast to the previous studies, we do not observe an increase in the OSL sensitivity of quartz with transport distance; for example...... shield areas (denudation rate ξ=0.04 mmyr−1), while low sensitivity quartz occurs in less stable Andean terrains (ξ=0.24 mmyr−1). An apparent linear correlation between quartz OSL sensitivity and denudation rate suggests that OSL sensitivity may be used as a proxy for erosion rates in the Amazon basin...

  15. Temperature dependence of the Al2O3:C response in medical luminescence dosimetry

    International Nuclear Information System (INIS)

    Edmund, Jens M.; Andersen, Claus E.

    2007-01-01

    Over the last years, attention has been given to applications of Al 2 O 3 :C in space and medical dosimetry. One such application is in vivo dose verification in radiotherapy of cancer patients and here we investigate the temperature effects on the radioluminescence (RL) and optically stimulated luminescence (OSL) signals in the room-to-body temperature region. We found that the OSL response changes with both irradiation and stimulation temperatures as well as the OSL integration time. We conclude that temperature effects on the OSL response can be removed by integration if the irradiation temperature is not varied. The RL response only depends on the irradiation temperature. We recommend that calibration should be carried out at the same irradiation temperature at which the measurement is performed (i.e. at body temperature for in vivo measurements). The overall change in the integrated OSL and RL signals with irradiation and stimulation temperature covers an interval from -0.2% to 0.6% per deg. C. This indicates the correction factor one must take into account when performing luminescence dosimetry at different temperatures. The same effects were observed regardless of crystal type, test doses and stimulation and detection wavelengths. The reported temperature dependence seems to be a general property of Al 2 O 3 :C

  16. Germanium-doped optical fiber for real-time radiation dosimetry

    International Nuclear Information System (INIS)

    Mizanur Rahman, A.K.M.; Zubair, H.T.; Begum, Mahfuza; Abdul-Rashid, H.A.; Yusoff, Z.; Ung, N.M.; Mat-Sharif, K.A.; Wan Abdullah, W.S.; Amouzad Mahdiraji, Ghafour; Amin, Y.M.; Maah, M.J.; Bradley, D.A.

    2015-01-01

    Over the past three decades growing demand for individualized in vivo dosimetry and subsequent dose verification has led to the pursuit of newer, novel and economically feasible materials for dosimeters. These materials are to facilitate features such as real-time sensing and fast readouts. In this paper, purposely composed SiO 2 :Ge optical fiber is presented as a suitable candidate for dosimetry. The optical fiber is meant to take advantage of the RL/OSL technique, providing both online remote monitoring of dose rate, and fast readouts for absorbed dose. A laboratory-assembled OSL reader has been used to acquire the RL/OSL response to LINAC irradiations (6 MV photons). The notable RL characteristics observed include constant level of luminescence for the same dose rate (providing better consistency compared to TLD-500), and linearity of response in the radiotherapy range (1 Gy/min to 6 Gy/min). The OSL curve was found to conform to an exponential decay characteristic (illumination with low LED source). The Ge doping resulted in an effective atomic number, Z eff , of 13.5 (within the bone equivalent range). The SiO 2 :Ge optical fiber sensor, with efficient coupling, can be a viable solution for in vivo dosimetry, besides a broad range of applications. - Highlights: • Purposely fabricated Ge doped silica fiber for real-time dose measurements. • Constant RL response for dose rates in radiotherapy range. • Linearity of RL curve during irradiation using LINAC. • RL response comparison between SiO 2 :Ge optical fiber and TLD-500.

  17. OSL dating of sediments from Negro and Solimões rivers – Amazon, Brazil

    International Nuclear Information System (INIS)

    Fiore, M.; Soares, E.A.A.; Mittani, J.C.R.; Yee, M.; Tatumi, S.H.

    2014-01-01

    In this work, the OSL dating results of Quaternary fluvial deposits from the confluence of Negro and Solimões rivers were studied. The equivalent doses (D e ) of sediments were obtained using a Single Aliquot Regeneration (SAR) protocol. Statistic studies were made using frequency histogram, weighted histogram and Radial plot in order to analyze the D e fluctuations. Ages from 74.5 to 205 thousand of years (Pleistocene) were recorded. The gamma-ray spectroscopy was used to evaluate the natural radioisotopes concentrations of the samples and low concentrations were found with values between 0.64 and 3.71 ppm for 235 U and 238 U; 2.01–9.77 ppm for 232 Th; already, for 40 K, the concentration was negligible. The OSL dating of sediments has contributed to a better understanding of the evolution of Negro and Solimões rivers, in Amazon, Brazil. - Highlights: ► OSL dating of fluvial terraces from Amazon. ► SAR protocols applied to Amazon sediments dating. ► OSL dating of Solimão and Negro rivers sediments

  18. Mechanical properties of rubberwood oriented strand lumber (OSL: The effect of strand length

    Directory of Open Access Journals (Sweden)

    Buhnnum Kyokong

    2005-09-01

    Full Text Available Effect of strand length on mechanical properties (tension, compression and bending of oriented strand lumber (OSL made of rubberwood (Hevea brasiliensis Muell. Arg. was reported. Three strand lengths of 50 mm, 100 mm, and 150 mm with 1 mm thickness and 15 mm width were used. The strands were mixed with 5% pMDI glue (weight basis in a tumble mixer. The OSL specimens were formed by hot pressing process of unidirectionally aligned strands. Average specific gravity and moisture content were 0.76 and 8.34%, respectively. Tension and compression tests were carried out for directions both parallel and perpendicular to grain while bending test was performed only in parallel direction. Ultimate stresses and moduli of elasticity were examined from the stress-strain curves. It was found that for the parallel-to-grain direction, the longer strand OSL gave higher strength. The role of the strand length did not appear for the direction normal to the grain. The relationship between the mechanical properties of OSL and strand length was well described by the modified Hankinson formula.

  19. Application of the Sunna dosimeter film in gamma and electron beam radiation processing

    DEFF Research Database (Denmark)

    Kovács, A.; Baranyai, M.; Wojnárovits, L.

    2000-01-01

    The OSL (optically stimulated luminescence) based Sunna film containing a microcrystalline dispersion of LIF in a polymer matrix has been recently introduced for high-dose dosimetry. Our previous investigations revealed the applicability of the system in the dose range of 0.01-100 kGy, but irradi...... significant in the case of OSL analysis for doses above 5 kGy. The applicability of two types of Sunna films in electron and gamma radiation processing is discussed in the paper. (C) 2000 Elsevier Science Ltd. All rights reserved.......The OSL (optically stimulated luminescence) based Sunna film containing a microcrystalline dispersion of LIF in a polymer matrix has been recently introduced for high-dose dosimetry. Our previous investigations revealed the applicability of the system in the dose range of 0.01-100 k......Gy, but irradiation temperature and dose rate effects above 5 kGy reduced its usefulness. The recent discovery of the use of spectrophotometric analysis in the UV range for measuring doses above 5 kGy is a suitable option, while the OSL analysis can be applied for measuring lower doses due to the lack of temperature...

  20. Luminescence dose of sand by the huguangyan maar lake

    International Nuclear Information System (INIS)

    Xiong Zhengye; Chen Jinmin; Ding Ping; Shi Wenqing; Ma Weijiang; Zhu Jinhan

    2010-01-01

    Sand samples were collected at different locations from the Huguangyan Maar Lake region in Zhanjiang, Guangdong province in south China. Thermoluminescence (TL) and optical stimulated luminescence (OSL) were measured with coarse grain technique. The TL and OSL dose response were analyzed and their ancient doses were calculated. The result shows that ancient doses measured with TL technique differ from those measured with OSL technique for the same sample, whereas for the samples whose TL ancient dose is close to the veraciousness, there were no evident degree of difference between the ancient doses by OSL and TL. The experiments and analyses can be used for reference in Quaternary period volcano dating. (authors)

  1. Comparison of single-grain and small-aliquot OSL dose estimates in < 3000 years old river sediments from South India

    DEFF Research Database (Denmark)

    Thomas, P.J.; Jain, M.; Juyal, N.

    2005-01-01

    We report on OSL dose distributions derived from small-aliquot and single grains of quartz in young fluvial sediments sampled from the Penner River basin, South India. The single-grain dose distributions suggest that 13 out of 19 samples were well bleached. In many well-bleached samples, there wa......We report on OSL dose distributions derived from small-aliquot and single grains of quartz in young fluvial sediments sampled from the Penner River basin, South India. The single-grain dose distributions suggest that 13 out of 19 samples were well bleached. In many well-bleached samples......, there was an underestimation in the single-aliquot dose estimates as compared to those from the single grain-the difference between average dose estimates determined by the two methods ranged from similar to 1% to 31%. Such a dose underestimation was not detectable in poorly bleached samples. Various possible reasons...... perhaps be one of the reasons; this may occur because the stimulation wavelength affects the proportion of the medium and slow components in the initial signal. (c) 2004 Elsevier Ltd. All rights reserved....

  2. Preliminary results on TL and OSL aluminium oxide dosimeters developed at IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Fukumori, David T.; Yoshito, Walter K.; Ussui, Valter; Lazar, Dolores R.R.; Campos, Leticia L., E-mail: fukumori@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The aluminum oxide composes the modern TL and OSL radiation dosimeters. TL and OSL phenomena are related to chemical elements in the crystalline structure of {alpha}-Al{sub 2}O{sub 3}. The aim of this work was to develop materials based on aluminum oxide for use in TL and OSL dosimetry. The studies included the dosimetric properties of alumina samples obtained by electro fusion, adsorption and coprecipitation. Electro fused alumina commercially available as abrasive particles was used to produce the pellets by glass sintering. Adsorption and coprecipitation were the methods used to insert metal ions to alumina. The best results were achieved with electro fused alumina and Tm{sup 3+} doped Al{sub 2}O{sub 3} pellets. The electro fused alumina-glass pellets show TL and OSL signals and the TL curve has two peaks. Its minimum detectable radiation dose is 7.2 mGy and the linearity of TL response as function of dose is up to about 800 mGy. The {alpha}-Al{sub 2}O{sub 3}:Tm pellets produced by sintering at 1550 deg C presented a meaningful TL glow curve so that it is worth studying their properties and viability of use in dosimetry. (author)

  3. Sources of uncertainty in individual monitoring for photographic,TL and OSL dosimetry techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Max S.; Silva, Everton R.; Mauricio, Claudia L.P., E-mail: max.das.ferreira@gmail.com, E-mail: everton@ird.gov.br, E-mail: claudia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The identification of the uncertainty sources and their quantification is essential to the quality of any dosimetric results. If uncertainties are not stated for all dose measurements informed in the monthly dose report to the monitored radiation facilities, they need to be known. This study aims to analyze the influence of different sources of uncertainties associated with photographic, TL and OSL dosimetric techniques, considering the evaluation of occupational doses of whole-body exposure for photons. To identify the sources of uncertainty it was conducted a bibliographic review in specific documents that deal with operational aspects of each technique and the uncertainties associated to each of them. Withal, technical visits to individual monitoring services were conducted to assist in this identification. The sources of uncertainty were categorized and their contributions were expressed in a qualitative way. The process of calibration and traceability are the most important sources of uncertainties, regardless the technique used. For photographic dosimetry, the remaining important uncertainty sources are due to: energy and angular dependence; linearity of response; variations in the films processing. For TL and OSL, the key process for a good performance is respectively the reproducibility of the thermal and optical cycles. For the three techniques, all procedures of the measurement process must be standardized, controlled and reproducible. Further studies can be performed to quantify the contribution of the sources of uncertainty. (author)

  4. Aluminium nitrate ceramics: A potential UV dosemeter material

    DEFF Research Database (Denmark)

    Trinkler, L.; Bøtter-Jensen, L.; Berzina, B.

    2002-01-01

    The ceramic material AIN-Y2O3 is proposed as a potential ultraviolet radiation (UVR) dosemeter using optically stimulated luminescence (OSL) and thermally stimulated luminescence (TL). Experimental studies have shown that AIN ceramics exhibit attractive characteristics suitable for practical UV...... dosimetry applications. The features are: (1) the spectral sensitivity covers the 200-350 nm range, in the UV-B region it is similar to that of human skin: (2) the angular dependence of the incident radiation follows the cosine law; (3) high yields of both UVR-induced OSL and TL signals compared to those...

  5. Infrared (IR) stimulated luminescence from modern bricks in retrospective dosimetry applications

    International Nuclear Information System (INIS)

    Niedermayer, M.; Goeksu, H.Y.; Dalheimer, A.; Bayer, A.

    2000-01-01

    It has frequently been observed that certain roof tiles and bricks, especially from relatively modern European buildings, do not contain enough quartz grains in a suitable grain size range to permit dose reconstruction using thermoluminescence (TL) or optically stimulated luminescence (OSL) methods. In this paper the feasibility of using infrared-stimulated luminescence (IRSL) on the feldspar fraction of such bricks and tiles has been investigated. Appropriate preheating treatments were employed in order to select the most stable signals, and procedures were developed to enhance the signal to noise ratio. The possible effect of anomalous fading under application of these procedures was tested. In the dose range above 100 mGy, it has been demonstrated that using IRSL on the feldspar fraction of such material provides a feasible alternative to the use of green-light-stimulated luminescence (GLSL) on the quartz fraction, for the purposes of retrospective dosimetry. Furthermore, since the use of IRSL as described in this paper involves the measurement of polymineral fine grain fractions of bricks, a technique for the calibration of the built-in β source against the γ source in Secondary Standard Dosimetry facilities for routine use of the technique is described

  6. Study of combinations of TL/OSL single dosimeters for mixed high/low ionization density radiation fields

    International Nuclear Information System (INIS)

    Oster, L.; Druzhyna, S.; Orion, I.; Horowitz, Y.S.

    2013-01-01

    In this paper we discuss and compare the potential application of combined OSL/TL measurements using 6 LiF:Mg,Ti (TLD-600 is enriched of isotope 6 Li which has a high cross-section for the reaction with slow neutrons) or 7 LiF:Mg,Ti ( TLD-700 is enriched of 7 Li isotope) and TLD-100 (natural isotopic composition) detectors. The OSL/TL duel readout of LiF:Mg,Ti as an ionization density discriminator avoids some of the difficulties inherent to the various types of discrimination mixed-field passive dosimeters, and in addition has several advantages. The preferential excitation of OSL compared to TL following high ionization density (HID) alpha irradiation, naturally explained via the identification of OSL with the “two-hit” F 2 or F 3 center, whereas the major component of composite TL glow peak 5 is believed to arise from a ''one-hit'' complex defect. This evidence allows near-total discrimination between HID radiation and low-ionization density (LID) radiation. Beta and alpha particle irradiations were carried out with 90 Sr/ 90 Y (∼500 keV average energy) and 241 Am sources (4.7 MeV) respectively and neutron irradiations were carried out at the PTB (Germany) (E n = 5 MeV) and RARAF (Columbia University, USA) (E n = 6 MeV) accelerator facilities. The highest values of the FOM obtained was ∼30 for neutron/gamma discrimination and ∼110 for alpha/gamma discrimination using OSL/TL – peak 5 measurements in TLD-700. -- Highlights: ► The increased response of OSL compared to TL following HID irradiation is observed. ► This evidence is explained via the identification of OSL with the ''two-hit'' F2 centers. ► The potential application of combined OSL/TL in discrimination dosimetry is discussed. ► The values of FOM were 110 for alpha/gamma and 30 for neutron/gamma discrimination

  7. Time-resolved luminescence from feldspars: New insight into fading

    DEFF Research Database (Denmark)

    Tsukamoto, S.; Denby, P.M.; Murray, A.S.

    2006-01-01

    Time-resolved infrared optically stimulated luminescence (IR-OSL) signals of K- and Na-feldspar samples extracted from sediments were measured in UV, blue and red detection windows, using a fast photon counter and pulsed IR stimulation (lambda = 875 nm). We observe that the relative contribution ...

  8. On the OSL curve shape and preheat treatment of electronic components from portable electronic devices

    DEFF Research Database (Denmark)

    Woda, Clemens; Greilich, Steffen; Beerten, Koen

    2010-01-01

    The shape of the OSL decay curve and the effect of longer time delays between accidental exposure and readout of alumina-rich electronic components from portable electronic devices are investigated. The OSL decay curve follows a hyperbolic decay function, which is interpreted as an approximation ...

  9. Detection of herbs and spices irradiated through optically stimulated luminescence; Deteccion de hierbas y especias irradiadas mediante luminiscencia opticamente estimulada

    Energy Technology Data Exchange (ETDEWEB)

    Preciado, S.; Agundez A, Z.; Barboza F, M. [Centro de Investigacion en Fisica, Universidad de Sonora, A.P. 5-088, 83190 Hermosillo, Sonora (Mexico); Cruz Z, E. [Instituto de Ciencias Nucleares de la UNAM, 04510 Mexico D.F. (Mexico)

    2003-07-01

    The irradiation of foods is one of the common practices in several countries of the American and European continents. In spite of the widespread use of irradiation methods and technics of nutritious products, it doesn't exist a method of general use at the present time for the detection of previously submitted foods to irradiation with pasteurization ends or sterilization. In the present work the results are presented obtained in the detection of herbs and spices exposed to radiation in the range of 0.1 - 3 KGy, by means of the photostimulation with light of 470 nm. It was used for it a RIS0 model team TL/OSL-GIVE-15 conditioned with a {beta} ray source, {sup 90}Sr/{sup 90}Y and a source of light of 50 mW/cm2. samples of chili guajillo were studied, pepper, cumin, mint and camomile; achieving you to detect exhibitions of the order of 8.33x10{sup -4} KGy that which is indicative of the high sensitivity of the luminescence technique optically stimulated. The answer of the samples with regard to the radiation dose presents a range of lineality for low dose of the order of 0.5 KGy; and supralineal for further dose without to arrive to a saturation stage. (Author)

  10. Implantable optical-electrode device for stimulation of spinal motoneurons

    International Nuclear Information System (INIS)

    Matveev, M V; Erofeev, A I; Zakharova, O A; Vlasova, O L; Pyatyshev, E N; Kazakin, A N

    2016-01-01

    Recent years, optogenetic method of scientific research has proved its effectiveness in the nerve cell stimulation tasks. In our article we demonstrate an implanted device for the spinal optogenetic motoneurons activation. This work is carried out in the Laboratory of Molecular Neurodegeneration of the Peter the Great St. Petersburg Polytechnic University, together with Nano and Microsystem Technology Laboratory. The work of the developed device is based on the principle of combining fiber optic light stimulation of genetically modified cells with the microelectrode multichannel recording of neurons biopotentials. The paper presents a part of the electrode implant manufacturing technique, combined with the optical waveguide of ThorLabs (USA). (paper)

  11. Cooled optically stimulated luminescence in CaF2:Mn

    International Nuclear Information System (INIS)

    Miller, S.D.; Endres, G.W.R.; McDonald, J.C.; Swinth, K.L.

    1988-01-01

    A new optically stimulated luminescence technique has been developed for the readout of CaF 2 :Mn thermoluminescent material. Minimum detectable gamma exposures may potentially be measured at 10 nC.kg -1 using the 254 nm line of a mercury lamp. Additional studies were done on CaF 2 :Mn using 351 nm excimer laser stimulation. (author)

  12. Radiation dosimeters for medical use

    International Nuclear Information System (INIS)

    Risticj, S. Goran

    2013-01-01

    The several personal radiation dosimeter types for medical use, which look like promising for this kind of application, as pMOS (RADFET) dosimeter, direct ion storage (DIS) dosimeters, thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters, are described, and their advantages and disadvantages are analyzed. The p-channel metal-oxide-semiconductor (pMOS) dosimetric transistors allow dose measurements in vivo in real time, and they are especially important for radiotherapy. Direct ion storage (DIS) dosimeters are a hybrid of ion chamber and floating gate MOSFETs (FGMOSFETs), show very high sensitivity. Radiative processes that happen during the exposure of crystal to radiation are classified as prompt luminescence or radioluminescence (RL). In the case of an emission during stimulation, this phenomenon is referred to thermoluminescence or optically stimulated luminescence depending on whether the stimulation source is heat or light. TL and OSL dosimeters are natural or synthetic materials, which the intensity of emitted light is proportional to the irradiation dose. (Author)

  13. Quaternary alluvial fans of Ciudad Juárez, Chihuahua, northern México: OSL ages and implications for climatic history of the region

    Science.gov (United States)

    Zúñiga de León, David; Kershaw, Stephen; Mahan, Shannon

    2016-01-01

    Alluvial fans formed from sediments derived from erosion of the Juárez Mountains in northernmost México have a significant flood impact on the Ciudad Juárez, which is built on the fan system. The northern part of Ciudad Juárez is the most active; further south, older parts of the fan, upon which the rest of the city is built, were largely eroded by natural processes prior to human habitation and subsequently modified only recently by human construction. Three aeolian sand samples, collected from the uppermost (youngest) parts of the fan system in the city area, in places where human intervention has not disturbed the sediment, and constrain the latest dates of fan building. Depositional ages of the Quaternary alluvial fans were measured using Optically Stimulated Luminescence (OSL) on aeolian sands that have inter-fingered with alluvial fan material. These dates are: a) sample P1, 31 ka; b) sample P2, 41 ka; c) sample P3, 74 ka, between Oxygen Isotope Stages (OIS) 3 to 5. They demonstrate that fan development, in the area now occupied by the city, terminated in the Late Pleistocene, immediately after what we interpret to have been an extended period of erosion without further deposition, lasting from the Late Pleistocene to Holocene. The three dates broadly correspond to global glacial periods, implying that the cool, dry periods may reflect periods of aeolian transport in northern México in between phases that were wetter to form the alluvial fans. Alluvial fan margins inter-finger with fluvial terrace sediments derived from the Río Bravo, indicating an additional component of fan dissection by Río Bravo lateral erosion, presumed to be active during earlier times than our OSL ages, but these are not yet dated. Further dating is required to ascertain the controls on the fan and fluvial system.

  14. Luminescence optically stimulated: theory and applications

    International Nuclear Information System (INIS)

    Rivera M, T.; Azorin N, J.

    2002-01-01

    The thermally stimulated luminescence (Tl) has occupied an important place in the Solid state physics (FES) by the flexibility of the phenomena, mainly for its applications in the fields of Radiation Physics (FR) and Medical Physics (MF). The reason of this phenomena lies in the fact of the electrons release by the action of heat. Under that same reason, it can be used the action of another stimulant agent for releasing the trapped electrons in the metastable states (EM), this agent is the light which has the same effect that the heat, giving as result the production of light photons at using light in the visible spectra, of different wavelength that the excitation light. This phenomena is called Luminescence optically stimulated (LOE). The LOE has a great impact in the Solid State Physics (FES), dating and now in the use of the phenomena as a dosimetric method, alternate to the Tl, for its use in the ionizing and non-ionizing radiations fields. (Author)

  15. Application of the optically stimulated luminescence (OSL) technique for mouse dosimetry in micro-CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Vrigneaud, Jean-Marc; Courteau, Alan; Oudot, Alexandra; Collin, Bertrand [Department of Nuclear Medicine, Centre Georges-François Leclerc, 1 rue Professeur Marion, Dijon 21079 Cedex (France); Ranouil, Julien [Landauer Europe, 33 avenue du Général Leclerc, Fontenay-aux-Roses 92266 Cedex (France); Morgand, Loïc; Raguin, Olivier [Oncodesign, 20 rue Jean Mazen, Dijon 21076 Cedex (France); Walker, Paul [LE2i CNRS UMR 5158, Faculty of Medicine, BP 87900, 21079 Dijon Cedex (France); Brunotte, François [Department of Nuclear Medicine, Centre Georges-François Leclerc, 1 rue Professeur Marion, Dijon 21079 Cedex, France and LE2i CNRS UMR 5158, Faculty of Medicine, BP 87900, 21079 Dijon Cedex (France)

    2013-12-15

    Purpose: Micro-CT is considered to be a powerful tool to investigate various models of disease on anesthetized animals. In longitudinal studies, the radiation dose delivered by the micro-CT to the same animal is a major concern as it could potentially induce spurious effects in experimental results. Optically stimulated luminescence dosimeters (OSLDs) are a relatively new kind of detector used in radiation dosimetry for medical applications. The aim of this work was to assess the dose delivered by the CT component of a micro-SPECT (single-photon emission computed tomography)/CT camera during a typical whole-body mouse study, using commercially available OSLDs based on Al{sub 2}O{sub 3}:C crystals.Methods: CTDI (computed tomography dose index) was measured in micro-CT with a properly calibrated pencil ionization chamber using a rat-like phantom (60 mm in diameter) and a mouse-like phantom (30 mm in diameter). OSLDs were checked for reproducibility and linearity in the range of doses delivered by the micro-CT. Dose measurements obtained with OSLDs were compared to those of the ionization chamber to correct for the radiation quality dependence of OSLDs in the low-kV range. Doses to tissue were then investigated in phantoms and cadavers. A 30 mm diameter phantom, specifically designed to insert OSLDs, was used to assess radiation dose over a typical whole-body mouse imaging study. Eighteen healthy female BALB/c mice weighing 27.1 ± 0.8 g (1 SD) were euthanized for small animal measurements. OLSDs were placed externally or implanted internally in nine different locations by an experienced animal technician. Five commonly used micro-CT protocols were investigated.Results: CTDI measurements were between 78.0 ± 2.1 and 110.7 ± 3.0 mGy for the rat-like phantom and between 169.3 ± 4.6 and 203.6 ± 5.5 mGy for the mouse-like phantom. On average, the displayed CTDI at the operator console was underestimated by 1.19 for the rat-like phantom and 2.36 for the mouse

  16. Investigation of the response characteristics of OSL albedo neutron dosimeters in a 241AmBe reference neutron field

    Science.gov (United States)

    Liamsuwan, T.; Wonglee, S.; Channuie, J.; Esoa, J.; Monthonwattana, S.

    2017-06-01

    The objective of this work was to systematically investigate the response characteristics of optically stimulated luminescence Albedo neutron (OSLN) dosimeters to ensure reliable personal dosimetry service provided by Thailand Institute of Nuclear Technology (TINT). Several batches of InLight® OSLN dosimeters were irradiated in a reference neutron field generated by the in-house 241AmBe neutron irradiator. The OSL signals were typically measured 24 hours after irradiation using the InLight® Auto 200 Reader. Based on known values of delivered neutron dose equivalent, the reading correction factor to be used by the reader was evaluated. Subsequently, batch homogeneity, dose linearity, lower limit of detection and fading of the OSLN dosimeters were examined. Batch homogeneity was evaluated to be 0.12 ± 0.05. The neutron dose response exhibited a linear relationship (R2=0.9974) within the detectable neutron dose equivalent range under test (0.4-3 mSv). For this neutron field, the lower limit of detection was between 0.2 and 0.4 mSv. Over different post-irradiation storage times of up to 180 days, the readings fluctuated within ±5%. Personal dosimetry based on the investigated OSLN dosimeter is considered to be reliable under similar neutron exposure conditions, i.e. similar neutron energy spectra and dose equivalent values.

  17. Quartz luminescence response to a mixed alpha-beta field: Investigations on Romanian loess

    DEFF Research Database (Denmark)

    Constantin, Daniela; Jain, Mayank; Murray, Andrew S.

    2015-01-01

    -OSL laboratory dose response curves do not reflect the growth of the OSL signal in nature. A main difference in coarse- and fine-grained quartz dating lies in the alpha irradiation history, but the effect of mixed alpha-beta fields has so far received little attention. In the present study we investigate whether...... the alpha dose experienced by fine grains over geological cycles of irradiation and bleaching may have an effect on the saturation characteristics of the laboratory dose response. By applying time resolved optically stimulated luminescence we confirm that the OSL signals induced in quartz by alpha and beta...

  18. Implantable optogenetic device with CMOS IC technology for simultaneous optical measurement and stimulation

    Science.gov (United States)

    Haruta, Makito; Kamiyama, Naoya; Nakajima, Shun; Motoyama, Mayumi; Kawahara, Mamiko; Ohta, Yasumi; Yamasaki, Atsushi; Takehara, Hiroaki; Noda, Toshihiko; Sasagawa, Kiyotaka; Ishikawa, Yasuyuki; Tokuda, Takashi; Hashimoto, Hitoshi; Ohta, Jun

    2017-05-01

    In this study, we have developed an implantable optogenetic device that can measure and stimulate neurons by an optical method based on CMOS IC technology. The device consist of a blue LED array for optically patterned stimulation, a CMOS image sensor for acquiring brain surface image, and eight green LEDs surrounding the CMOS image sensor for illumination. The blue LED array is placed on the CMOS image sensor. We implanted the device in the brain of a genetically modified mouse and successfully demonstrated the stimulation of neurons optically and simultaneously acquire intrinsic optical images of the brain surface using the image sensor. The integrated device can be used for simultaneously measuring and controlling neuronal activities in a living animal, which is important for the artificial control of brain functions.

  19. Local probing and stimulation of neuronal cells by optical manipulation

    Science.gov (United States)

    Cojoc, Dan

    2014-09-01

    During development and in the adult brain, neurons continuously explore the environment searching for guidance cues, leading to the appropriate connections. Elucidating these mechanisms represents a gold goal in neurobiology. Here, I discuss our recent achievements developing new approaches to locally probe the growth cones and stimulate neuronal cell compartments with high spatial and temporal resolution. Optical tweezers force spectroscopy applied in conjunction with metabolic inhibitors reveals new properties of the cytoskeleton dynamics. On the other hand, using optically manipulated microvectors as functionalized beads or filled liposomes, we demonstrate focal stimulation of neurons by small number of signaling molecules.

  20. Optimization of laboratory illumination in optical dating

    DEFF Research Database (Denmark)

    Sohbati, Reza; Murray, Andrew; Lindvold, Lars René

    2017-01-01

    As part of the development of new laboratory lighting, we present a methodological approach applicable to the characterization of any light source intended for illumination in optical dating laboratories. We derive optical absorption cross-sections for quartz and feldspar from published data......-emitting diodes (LEDs); this comparison demonstrates the significant advantage of the LED sources over the filtered light sources, because essentially all of the reduction of both OSL and IRSL signals by the LEDs occurs at wavelengths to which the human eye is most sensitive. We conclude that exposure of quartz...... and feldspar extracts from various samples to the light from an LED with emission peak at 594 nm results in a 1% OSL or IRSL signal loss for a 48-h exposure at a power density of ~0.2 mW.cm-2....

  1. Luminescence dating

    International Nuclear Information System (INIS)

    Rieser, U.

    2013-01-01

    The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materials in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14 C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs.

  2. Luminescence dating

    International Nuclear Information System (INIS)

    Rieser, U.

    2009-01-01

    The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materals in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14 C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs.

  3. Luminescence dating

    International Nuclear Information System (INIS)

    Rieser, U.

    2008-01-01

    The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materals in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14 C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs

  4. Luminescence dating

    International Nuclear Information System (INIS)

    Rieser, U.

    2012-01-01

    The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materials in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14 C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs.

  5. Luminescence dating

    International Nuclear Information System (INIS)

    Rieser, U.

    2009-01-01

    The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materals in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14 C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs

  6. Thermal transfer and apparent-dose distributions in poorly bleached mortar samples: Results from single grains and small aliquots of quartz

    DEFF Research Database (Denmark)

    Jain, M.; Thomsen, Kristina Jørkov; Bøtter-Jensen, L.

    2004-01-01

    In the assessment of doses received from a nuclear accident, considerable attention has been paid to retrospective dosimetry using the optically stimulated luminescence (OSL) of heated materials such as bricks and tiles. Quartz extracted from these artefacts was heated during manufacture;, this p......In the assessment of doses received from a nuclear accident, considerable attention has been paid to retrospective dosimetry using the optically stimulated luminescence (OSL) of heated materials such as bricks and tiles. Quartz extracted from these artefacts was heated during manufacture......;, this process releases all the prior trapped charge and simultaneously sensitises the quartz. Unfortunately unheated materials such as mortar and concrete are more common in industrial sites and particularly in nuclear installations. These materials are usually exposed to daylight during quarrying...... dosimetry. The challenge in using such materials as retrospective dosemeters, is in identifying these well-bleached grains when an accident dose has been superimposed on the original dose distribution. We investigate here, using OSL, the background dose in three different mortar samples: render, whitewash...

  7. Testing optically stimulated luminescence dating on sand-sized quartz of deltaic deposits from the Sperchios delta plain, central Greece

    Directory of Open Access Journals (Sweden)

    Evangelos Tsakalos

    2018-04-01

    Full Text Available This study reports on the first investigation into the potential of luminescence dating to establish a chronological framework for the depositional sequences of the Sperchios delta plain, central Greece. A series of three borehole cores (20 m deep and two shallow cores (4 m deep, from across the delta plain, were extracted, and samples were collected for luminescence dating. The luminescence ages of sand-sized quartz grains were obtained from small aliquots of quartz, using the Single-Aliquot Regenerative-dose (SAR protocol. The equivalent dose determination included a series of tests and the selection of the Minimum Age Model (MAM as the most appropriate statistical model. This made it possible to confirm the applicability of quartz Optically Stimulated Luminescence (OSL dating to establish absolute chronology for deltaic sediments from the Sperchios delta plain.Testing age results of the five cores showed that the deltaic sediments were deposited during the Holocene. A relatively rapid deposition is implied for the top ∼14 m possibly as a result of the deceleration in the rate of the sea-level rise and the transition to terrestrial conditions, while on the deeper parts, the reduced sedimentation rate may indicate a lagoonal or coastal environment. Keywords: Luminescence dating, Holocene, Sedimentation rates, Deltaic deposits, Sperchios delta plain, Central Greece

  8. The dependence of dose recovery experiments on the bleaching of natural quartz OSL using different light sources

    International Nuclear Information System (INIS)

    Choi, J.H.; Murray, A.S.; Cheong, C.-S.; Hong, S.C.

    2009-01-01

    In this paper, the dependence of dose recovery tests on the different bleaching light sources (blue-LEDs, solar simulator, natural sunlight) is investigated with a variety of sedimentary quartz samples, selected so that their OSL signals are dominated by the fast OSL component. We observed that when long solar simulator bleaching was applied, various known doses were underestimated in an SAR-based dose recovery test. However, when blue-LEDs and short solar simulator bleaching were used (10 s and 60 s) the known doses were accurately recovered. In repeated measurement of the OSL signals induced by the same regeneration and test dose, we observed a considerable increase in quartz OSL sensitivity during or after the first OSL measurement when long solar simulator bleaching was used; this seems to provide a possible explanation for the observed underestimation of the laboratory known doses. A series of experimental results using a sample from a modern aeolian dune surface shows that there are no subsequent sensitivity changes when the naturally zeroed samples are bleached with sunlight for long time. It seems that there is a dependence of the sensitivity change on the amount of dose administered before solar simulator bleaching and on the light intensity of solar simulator. When small doses were given to the naturally zeroed sample, the sensitivity change during or after the first OSL measurement was not significant. However, when a considerable amount of beta dose (∼4000 Gy) is administered to the sample, a clear sensitivity change during or after the first OSL measurement (∼20%) was observed. Such a sensitivity change was not observed when the bleaching light intensity of solar simulator was reduced by increasing the distance between samples and the UV lamp. Our results show that, at least for the samples described here, the outcomes of dose recovery experiments are dependent on the bleaching conditions.

  9. ELI-NP Tesislerinde Radyasyon Dozimetri Laboratuvarı için Kalite Yönetim Sisteminin (QMS) Teknik Yönleri

    OpenAIRE

    Dorina ARANGHEL; Doina STANCIU; Chivuta-Ramona BADITA; Ana STOCHIOIU; Ion TUDOR

    2018-01-01

    The individual andenvironmental passive monitoring program of the Extreme Light Infrastructure -Nuclear Physics (ELI-NP) will use a combination of Optically StimulatedLuminescence (OSL) and Solid State Nuclear Track Detector – (SSNTD) detectors.The OSL dosimeters are dedicated for X-rays/gamma radiation monitoring and willcontain BeO detectors which provide the personal dose equivalent and theambient dose equivalent or the directional dose equivalent according to SR EN62387-1:2012. The SSNTDs...

  10. Luminescence characteristics of quartz from Hsuehshan Range (Central Taiwan) and implications for thermochronometry

    DEFF Research Database (Denmark)

    Wu, Tzu-Shuan; Jain, Mayank; Guralnik, Benny

    2015-01-01

    The mountain building processes in Taiwan are currently among the most rapid in the world. However, the spatial and temporal dynamics of this orogen are still poorly resolved within the .... Optically Stimulated Luminescence (OSL) from quartz is an emerging thermochronometer that could potentially provide valuable low-temperature markers on a ~0.1 Ma timescale. Here we study four meta-sandstone samples from the Hsuehshan Range in central Taiwan. We characterize the OSL from these samples...

  11. Luminescence properties of common salt (NaCl available in Nigeria for use as accident dosimeter in radiological emergency situation

    Directory of Open Access Journals (Sweden)

    Janet Ayobami Ademola

    2017-04-01

    Full Text Available In the event of a radiological accident or attack, it is important to assess and quantify radiation dose to the population. This could be done using materials in the vicinity that are sensitive to ionizing radiation. Common salt (NaCl is known to be a sensitive thermoluminescence (TL phosphor. Luminescence properties of common salt (NaCl used in Nigeria were investigated using an automated luminescence reader Risø TL/OSL-DA-15, with attention focused more on the Optically Stimulated Luminescence (OSL. Strong radiation-induced TL and OSL signals were observed. The TL peaks occurred at about 100 °C, 240 °C and 280 °C. The dose response of both the TL and OSL signals showed a linear relationship. From the OSL pulse anneal curve with TL curve, a preheat temperature of 190 °C for 10 s was found adequate for the OSL measurements. There was no significant difference in the OSL decay for stimulation temperatures of 100 and 120 °C. Fading experiment over a storage period of 14 days showed about 13 and 3% decrease in the OSL signal of sample 1 and sample 2, respectively. The ratios of measured to given dose for dose recovery test were within ±19% of unity. Within the limit of error the samples could be used as a complementary emergency dosimeter in radiological accident situation.

  12. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    International Nuclear Information System (INIS)

    Kikuti, C.F.; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C.

    2015-01-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  13. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kikuti, C.F. [Universidade Federal do Mato Grosso do Sul (UFMS), Campo Grande, MS (Brazil). Hospital Universitario Maria Aparecida Pedrossian; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C., E-mail: daros.kellen@unifesp.br [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Departamento de Diagnostico por Imagem

    2015-07-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  14. Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison

    International Nuclear Information System (INIS)

    Bassinet, C.; Woda, C.; Bortolin, E.; Della Monaca, S.; Fattibene, P.; Quattrini, M.C.; Bulanek, B.; Ekendahl, D.; Burbidge, C.I.; Cauwels, V.; Kouroukla, E.; Geber-Bergstrand, T.; Mrozik, A.; Marczewska, B.; Bilski, P.; Sholom, S.; McKeever, S.W.S.; Smith, R.W.; Veronese, I.

    2014-01-01

    In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses. - Highlights: • Resistors in mobile phones could function as reliable fortuitous dosimeters in case of a large scale radiological accident. • Two OSL protocols were validated by an inter-laboratory comparison. • It is feasible to set up a network of laboratories so as to increase the measurement capacity

  15. On the use of new generation mobile phone (smart phone) for retrospective accident dosimetry

    International Nuclear Information System (INIS)

    Lee, J.I.; Chang, I.; Pradhan, A.S.; Kim, J.L.; Kim, B.H.; Chung, K.S.

    2015-01-01

    Optically stimulated luminescence (OSL) characteristics of resistors, inductors and integrated-circuit (IC) chips, extracted from new generation smart phones, were investigated for the purpose of retrospective accident dosimetry. Inductor samples were found to exhibit OSL sensitivity about 5 times and 40 times higher than that of the resistors and the IC chips, respectively. On post-irradiation storage, the resistors exhibited a much higher OSL fading (about 80 % in 36 h as compared to the value 3 min after irradiation) than IC chips (about 20 % after 36 h) and inductors (about 50 % in 36 h). Higher OSL sensitivity, linear dose response (from 8.7 mGy up to 8.9 Gy) and acceptable fading make inductors more attractive for accident dosimetry than widely studied resistors. - Highlights: • OSL properties of electronic components from a smart phone were investigated. • OSL Sensitivity of inductor was estimated to 5 times higher than that of resistor. • Inductor exhibits most attractive properties for retrospective accident dosimetry.

  16. Fake age hiatus in a loess section revealed by OSL dating of calcrete nodules

    Science.gov (United States)

    Zhang, Junjie; Li, Sheng-Hua; Sun, Jimin; Hao, Qingzhen

    2018-04-01

    Optically stimulated luminescence (OSL) dating on potassium feldspar has been performed with high resolution in the Luochuan section in the Chinese Loess Plateau. An age hiatus of ∼ 15 ka is found at the top of L2 layer within the loess/paleosol sequences. The age of the potassium feldspar from the calcrete nodules along the S1/L2 boundary is significantly older than those of the paleosol and loess samples lying above and below the boundary. The age overestimation of the potassium feldspar from calcrete nodules is caused by the underestimation of the dose rate, because accretion of carbonates could dilute the radioactivity. The age hiatus at the top of L2 also resulted from the underestimation of the dose rates of four loess samples beneath this hiatus. These four loess samples have high CaO concentrations. Ages of these samples are overestimated in the similar way as the nodules, but with smaller degrees. All results suggest that the accretion of carbonates happened after the loess deposition. The carbonate accretion process of the calcrete nodules has been simulated with accumulation models. The accretion can be as young as 46 ka, assuming the calcrete nodules formed rapidly at a certain time point. For slow and gradual accretion models, the carbonate started to accumulate slowly since the dust deposition and the accumulation became faster afterwards. The transition of the accretion rate may relate to the climate change or a change in the carbonate leaching and re-precipitation system.

  17. An integrated OSL chronology, sedimentology and geochemical approach to loess deposits from Tuoji Island, Shandong Province: Implications for the late quaternary paleoenvironment in East China

    Science.gov (United States)

    Xu, Shujian; Kong, Fanbiao; Jia, Guangju; Miao, Xiaodong; Ding, Xinchao

    2018-04-01

    The Tuoji II (TJII) section on the Miaodao Islands in the Bohai Sea is a representative aeolian section off China's east coast. This study applied optically stimulated luminescence (OSL) dating, conducted grain size analysis, and examined major and trace element compositions, to investigate the loess-paleosol sequences. The OSL ages at depths of 0.6, 1.8, 2.8, 3.8, and 4.8 m were determined as 14.4 ± 0.4, 16.7 ± 1.3, 20.8 ± 1.0, 40.9 ± 1.5, and 47.9 ± 3.7 ka, respectively. It was projected that the loess started to accumulate at ca. 62.6 ka, according to presumed depositional rates. In this study, typical aeolian deposits elsewhere including the Luochuan (LC), Xiashu (XS), Wushan (WS), and Xifeng (XF) sections were compared with TJII section here. The results showed similarity in the geochemical characteristics of the deposits from the different areas of China and normalized upper continental crust, indicating aeolian origin of this island loess. In comparison with the LC, XS, WS, and XF samples, the aeolian deposits of the TJII section have higher concentrations of TiO2 and Zr and lower concentrations of Al2O3, Rb, and Ni, and they have higher SiO2/Al2O3 and TiO2/Al2O3 ratios and lower Al2O3/Na2O and Ba/Sr ratios. These features indicate the dust materials of the TJII section were derived from local sources of well-mixed sedimentary protoliths. Our results support the suggestion that paleoclimatic change and the evolution of aeolian sediments were controlled primarily by variation of the East Asian summer monsoon and sea level change.

  18. The study on pre-heat conditions in the equivalent-dose estimation of holocene loess using the single-aliquot regenerative-dose (SAR) protocol

    International Nuclear Information System (INIS)

    Jia Yaofeng; Huang Chunchang; Pang Jiangli; Lu Xinwei; Zhang Xu

    2008-01-01

    The thermal treatment in the equivalent-dose estimation often is carried in the OSL dating, and pre-heat is a main thermal treatment. Due to which will originate the problems of thermal transfer and thermal activation, the thermal treatment and the setup of their conditions are key problems influencing the accuracy of OSL dating. The paper combined the temperature of pre-heat and cut-heat used in the routine measurement of IRSL and Post-IR OSL, and then estimated the equivalent-dose of several loess samples. The estimated result presents that the equivalent-dose depends on the heat temperature, especially depends on the cut-heat temperature, which is to say that the equivalent-dose increases with the cut-heat temperature; a plateau of equivalent-dose appears when using the 200-240 degree C cut-heat in the range of 200-300 degree C pre-heat, and the equivalent-doses estimated by IRSL and Post-IR OSL respectively are close to each other, which resulted from the similar sensitivity change direction of optical stimulated signals and its smaller change range in the measurement cycles using the combined temperature of pre- heat and cut-heat, and the incomplete calibration of sensitivity change of optical stimulated signals in the whole measurement cycles caused the variation of estimated equivalent-dose corresponding to the cut-heat temperature. (authors)

  19. New age estimations for the western outer city wall of ancient Tayma (NW Saudi Arabia) based on OSL and radiocarbon data and geomorphologic evidence

    Science.gov (United States)

    Engel, M.; Klasen, N.; Brückner, H.; Eichmann, R.; Hausleiter, A.; Al-Najem, M. H.; Al-Said, S. F.; Schneider, P. I.

    2009-04-01

    Since 2004 tremendous progress has been achieved in deciphering the cultural genesis of the Tayma oasis (NW Saudi Arabia), due to the joint investigations of the German Archaeological Institute Berlin (DAI), the General Commission for Tourism and Antiquities, Kingdom of Saudi Arabia, and the Department of Archaeology and Epigraphy, King Saud University Riyadh. Nevertheless, archaeological research is still suffering from a lacking locally-based absolute chronology of buildings. The pattern of ancient constructions at Tayma is dominated by a prominent city wall system surrounding the ancient town center (Qraya) and stretching 15 km around the oasis. Its internal structure indicates several building periods, i.e. phases of wall modification or extension of the entire system. So far, according to silex and carnelian fragments included in the mud bricks and a previous 14C age of charcoal remains from the central excavation district (wall section at Area A), an initial construction date of the wall between the late 3rd and the early 2nd millennium BC seemed likely. At the excavated western outer city wall a new systematic dating approach - combining the optically stimulated luminescence (OSL) and 14C methods - has been applied to generate a reliable age for the oldest branch of the wall system which nowadays is covered by aeolian sand. The dune deposit is genetically related to the existence of the wall and, therefore, dating its accumulation provides termini ante quem for the construction of the wall. Five OSL dates were generated from the dune deposit providing ages between 4,900 and 3,500 yrs. Two radiocarbon ages support the dating sequence and also contribute to its consistency. By combining the results with geomorphologic evidence we draw the following conclusions: Initial settlement activities at Qraya were accompanied by a regulation of wadi dynamics and the construction of the outer city wall, indicated by the abrupt boundary between the pre-settlement alluvial

  20. Dosimeter properties of Ce and Eu doped LiCaAlF6

    International Nuclear Information System (INIS)

    Yanagida, Takayuki; Fujimoto, Yutaka; Watanabe, Kenichi; Fukuda, Kentaro

    2014-01-01

    Optical, scintillation properties, optical stimulated luminescence, and thermally stimulated luminescence of Ce 1, 3, and 5% doped and Eu 1, 1.5, and 2% doped LiCaAlF 6 crystals fabricated by Tokuyama Corp. were investigated. In transmittance, absorption was proportional to dopant concentrations and typical optical quantum yield of Ce and Eu-doped LiCaAlF 6 were 40 and 100%, respectively. Scintillation wavelength and decay time profiles were investigated under X-ray irradiation. Ce 3+ and Eu 2+ 5d-4f luminescence appeared around 300 nm and 370 nm with typical decay time of 40 ns and 1.5 μs, respectively. Optically stimulated luminescence of Ce-doped ones appeared under 405 nm stimulation with detectable intensity while those of Eu doped ones were quite weak. Thermally stimulated luminescence of Ce- and Eu-doped LiCaAlF 6 were enough strong and they exhibited good response function from 1 to 1000 mGy exposure. - Highlights: • Optical, scintillation, OSL, and TSL properties of Ce or Eu differently doped LiCaAlF6 were studied. • PL quantum yield of Ce and Eu doped LiCaAlF6 showed 40% and 100%, respectively. • OSL was observed in Ce-doped LiCaAlF6. • TSL was observed in both material systems and exhibited a good dose response from 1 to 1000 mGy

  1. All-optical bidirectional neural interfacing using hybrid multiphoton holographic optogenetic stimulation.

    Science.gov (United States)

    Paluch-Siegler, Shir; Mayblum, Tom; Dana, Hod; Brosh, Inbar; Gefen, Inna; Shoham, Shy

    2015-07-01

    Our understanding of neural information processing could potentially be advanced by combining flexible three-dimensional (3-D) neuroimaging and stimulation. Recent developments in optogenetics suggest that neurophotonic approaches are in principle highly suited for noncontact stimulation of network activity patterns. In particular, two-photon holographic optical neural stimulation (2P-HONS) has emerged as a leading approach for multisite 3-D excitation, and combining it with temporal focusing (TF) further enables axially confined yet spatially extended light patterns. Here, we study key steps toward bidirectional cell-targeted 3-D interfacing by introducing and testing a hybrid new 2P-TF-HONS stimulation path for accurate parallel optogenetic excitation into a recently developed hybrid multiphoton 3-D imaging system. The system is shown to allow targeted all-optical probing of in vitro cortical networks expressing channelrhodopsin-2 using a regeneratively amplified femtosecond laser source tuned to 905 nm. These developments further advance a prospective new tool for studying and achieving distributed control over 3-D neuronal circuits both in vitro and in vivo.

  2. Re-evaluating luminescence burial doses and bleaching of fluvial deposits using Bayesian computational statistics.

    NARCIS (Netherlands)

    Cunningham, A.C.; Wallinga, J.; Versendaal, Alice; Makaske, A.; Middelkoop, H.; Hobo, N.

    2015-01-01

    The optically stimulated luminescence (OSL) signal from fluvial sediment often contains a remnant from the previous deposition cycle, leading to a partially bleached equivalent-dose distribution. Although identification of the burial dose is of primary concern, the degree of bleaching could

  3. Re-evaluating luminescence burial doses and bleaching of fluvial deposits using Bayesian computational statistics

    NARCIS (Netherlands)

    Cunningham, A. C.; Wallinga, J.; Hobo, N.; Versendaal, A. J.; Makaske, B.; Middelkoop, H.

    2015-01-01

    The optically stimulated luminescence (OSL) signal from fluvial sediment often contains a remnant from the previous deposition cycle, leading to a partially bleached equivalent-dose distribution. Although identification of the burial dose is of primary concern, the degree of bleaching could

  4. Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence

    International Nuclear Information System (INIS)

    Beerten, K.; Vanhavere, F.

    2010-01-01

    New data are presented with regard to the relative OSL sensitivity of three different emergency dosemeters irradiated to various photon energies approximately between 48 and 1250 keV using blue excitation light. Investigated components extracted from commonly worn objects include those from USB flash drives (alumina substrate), mobile phones (Ba-rich silicate) and credit cards (chip card module). Several basic properties have been investigated such as the overall radiation sensitivity, the shape of the decay curve and fading of the OSL signal. An increase of the sensitivity for low energies relative to 60 Co gamma rays can be observed for the three dosemeters, the increase being very pronounced for the Ba-rich component (factor of 10) and less pronounced for the chip card module (factor of 2). It is concluded that proper dose correction factors for photon energy have to be applied in order to accurately determine the absorbed dose to tissue. The OSL sensitivity to neutron irradiation was investigated as well, but this was found to be less than the gamma sensitivity. (authors)

  5. Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence.

    Science.gov (United States)

    Beerten, Koen; Vanhavere, Filip

    2010-08-01

    New data are presented with regard to the relative OSL sensitivity of three different emergency dosemeters irradiated to various photon energies approximately between 48 and 1250 keV using blue excitation light. Investigated components extracted from commonly worn objects include those from USB flash drives (alumina substrate), mobile phones (Ba-rich silicate) and credit cards (chip card module). Several basic properties have been investigated such as the overall radiation sensitivity, the shape of the decay curve and fading of the OSL signal. An increase of the sensitivity for low energies relative to (60)Co gamma rays can be observed for the three dosemeters, the increase being very pronounced for the Ba-rich component (factor of 10) and less pronounced for the chip card module (factor of 2). It is concluded that proper dose correction factors for photon energy have to be applied in order to accurately determine the absorbed dose to tissue. The OSL sensitivity to neutron irradiation was investigated as well, but this was found to be less than the gamma sensitivity.

  6. Correlation between TL and OSL signals in KMgF3:Ce3+: Bleaching study of individual glow-peaks

    International Nuclear Information System (INIS)

    Dallas, G.I.; Polymeris, G.S.; Afouxenidis, D.; Tsirliganis, N.C.; Tsagas, N.F.; Kitis, G.

    2010-01-01

    KMgF 3 :Ce 3+ is an ultra sensitive Thermoluminescence (TL) material with a complex TL and OSL glow-curve structure. The aim of the present work is to attempt a one-to-one correspondence between specific TL glow-peaks and OSL components in KMgF 3 :Ce 3+ . The correlation study involves the deconvolution of the TL curves and the estimation of the bleaching decay constants for individual glow-peaks followed by the deconvolution of the LM-OSL curve using the estimated decay constants. It was found that the bleaching of each individual glow-peak takes place in three different rates; namely in a fast, medium and slow rate.

  7. Passive dosimetry: introduction of a new dosimeter based on OSL technology

    International Nuclear Information System (INIS)

    Archambault, V.; Le Roy, G.; Prugnaud, B.

    2005-01-01

    A new passive dosimeter based on OSL technology has been introduced on the French market. In this article are described: the technology and the material on which this new detector relied, the dosimeter itself. (author)

  8. Search for the dose-sensitive optically stimulated luminescence response in natural carbonates

    International Nuclear Information System (INIS)

    Jaek, Ivar; Huett, Galina; Rammo, Ilmar; Vasilchenko, Valeri

    2001-01-01

    Carbonates of different origin, such as Iceland spar, calcites, and mollusc shells, used as electron spin resonance and thermoluminescence paleodosimeters, were studied in order to determine their suitability for optically stimulated luminescence dating. The stimulation/excitation spectra of the afterglow of the samples were recorded in the wavelength range of 250-1100 nm. The results of the study show that these spectra present either excitation spectra of Mn 2+ ion fluorescence (samples of calcites and Iceland spar, red emission recorded) or the excitation spectra of primary phosphorescence (samples of carbonates, including molluscs shells; short-wave emission bands recorded). The recorded stimulation spectra revealed no spectral bands sensitive to stimulation by ionizing radiation, which would disappear as a result of heating and could thus be related to deep traps in carbonates, needed dating. The cause of this situation which is unusual in luminescent crystals, including luminescence (paleo)dosimeters, and the ways of overcoming the difficulties in optical dating of natural carbonates are discussed. (author)

  9. Improvement of the M/S manipulator maintenance at OSL

    International Nuclear Information System (INIS)

    Kuwana, Koichi; Ouchi, Hiroshi; Ito, Yutaka; Sato, Yoshihiro; Midorikawa, Mituhiro; Hayakawa, Tuyoshi

    2010-01-01

    The safeguards inspection samples from the JNFL Rokkasho Reprocessing Plant (RRP) are received and analyzed at the On Site Laboratory (OSL). Since the samples from the input accountancy tank of the RRP contain a lot of fission products, they are treated in a hot-cell line with a M/S (Master /Slave) manipulator. Special equipment and tools were used for the maintenance of the M/S manipulator, especially for the exchange of the M/S manipulator. However, the manipulator exchange work was not easy due to the limitation of the space in the OSL. For solution to this problem, a monorail and monorail hoist equipment was installed onto wall surface of analytical room close to each M/S manipulator, and then it made the exchange of M/S manipulator easy without special equipment and tools. Additionally, operator was freed from the burden of working space arranging for the exchange of M/S manipulator such as removing of analytical equipments. This report represents the improvement of operation for the exchange of M/S manipulator with installation of monorail and hoist equipment. (author)

  10. Luminescence dating of flash flood deposits: a new approach for the chronological study of ancient irrigation perimeters in southern Yemen

    International Nuclear Information System (INIS)

    Balescu, S.; Lamothe, M.; Coque-Delhuille, B.

    1998-01-01

    This study is an attempt to assess the age of ancient irrigation silts from Southern Yemen using the optically stimulated luminescence (OSL) of the constituent K-feldspar grains. This OSL dating method is tested on the al-Haraja irrigation sequence (Wadi Bayhan) which overlies an archaeological occupation level previously dated at 2 203±123 years BP by 14 C. The OSL age estimates range between 2 097±177 years at the bottom of the sequence and 1 555±150 years at the top. This study demonstrates the potential of the luminescence dating method to provide chronological information on the deposition of ancient silts following irrigation in arid environment where 14 C datable material is rare. (authors)

  11. Testing the application of quartz and feldspar luminescence dating to MIS 5 Japanese marine deposits

    DEFF Research Database (Denmark)

    Thiel, Christine; Tsukamoto, Sumiko; Tokuyasu, Kayoko

    2015-01-01

    The applicability of both quartz and feldspar luminescence dating was tested on twenty-five samples from a marine succession now forming a coastal cliff at Oga Peninsula, Honshu Island, Japan. The quartz optically stimulated luminescence (OSL) signal shows thermal instability and linear modulated...

  12. LM-OSL from single grains of quartz: A preliminary study

    DEFF Research Database (Denmark)

    Bulur, E.; Duller, G.A.T.; Solongo, S.

    2002-01-01

    the easy-to-bleach component, those with only the hard-to-bleach component, and those exhibiting all components. The results of this preliminary study show that LM-OSL experiments carried out at the single grain level may give important insights into the luminescence properties observed when viewing...

  13. Thermally assisted OSL from deep traps in Al2O3:C

    International Nuclear Information System (INIS)

    Polymeris, G.S.; Raptis, S.; Afouxenidis, D.; Tsirliganis, N.C.; Kitis, G.

    2010-01-01

    The present work suggests an alternative experimental method in order to not only measure the signal of the deep traps in Al 2 O 3 :C without heating the sample to temperatures greater than 500 o C, but also use this signal for high dose level dosimetry purposes as well. This method consists of photo transfer OSL measurements performed at elevated temperatures using the blue LEDs (470 nm, FWHM 20 nm) housed at commercial Riso TL/OSL systems, after the sample was previously heated up to 500 o C in order to empty its main TL dosimetric trap. The influence of this procedure on specific features such as glow curve shape and sensitivity of the main TL glow peak was also studied.

  14. Optical dating using feldspar from Quaternary alluvial and colluvial sediments from SE Brazilian Plateau, Brazil

    International Nuclear Information System (INIS)

    Tatumi, Sonia H.; Peixoto, Maria Naise O.; Moura, Josilda R.S.; Mello, Claudio L.; Carmo, Isabela O.; Kowata, Emilia A.; Yee, Marcio; Brito, Silvio Luiz M.; Gozzi, Giuiliano; Kassab, Luciana R.P.

    2003-01-01

    Opticallly stimulated luminescence (OSL) dating has been applied to a wide variety of materials such as loess, sand dunes, colluvium, alluvium, volcanic products, etc., helping geologic geomorphologic studies. OSL dating results using feldspar crystals extracted from alluvial and colluvial deposits of SE Brazilian Plateau will be presented in this work. The methodology used is based on the regeneration method, with multiple aliquot protocol. A total of 23 sample ages were obtained spanning 6.5-97.2 kyr. Results of radioactive contents and comparison with radiocarbon ages will be discussed

  15. Luminescence quartz dating of lime mortars. A first research approach

    International Nuclear Information System (INIS)

    Zacharias, N.; Mauz, B.; Michael, C.T.

    2002-01-01

    Lime mortars mixed with sand are well suited for connecting structural materials, like stones and bricks, due to the mechanical properties this material exhibits. Their extensive use in architectural and decorative works during the last 4000 years motivated the introduction of the 'Luminescence clock' for age determination of mortars. The same principles as for quartz optically stimulated luminescence (OSL) dating of sediments were applied for age estimation of a mortar fragment removed from a Byzantine church monument dated by archaeological means to 1050-1100 years ago (the first half of the 10th century). The OSL from the quartz was monitored under blue light stimulation and UV detection, using a single-aliquot-regenerative-dose protocol. The quartz-OSL dating of the mortar resulted in 870±230 a. TL polymineral fine grain dating was also performed on a brick fragment which was connected to the mortar, resulting in a TL age of 1095±190 a. (author)

  16. Electrical and optical co-stimulation in the deaf white cat

    Science.gov (United States)

    Cao, Zhiping; Xu, Yingyue; Tan, Xiaodong; Suematsu, Naofumi; Robinson, Alan; Richter, Claus-Peter

    2018-02-01

    Spatial selectivity of neural stimulation with photons, such as infrared neural stimulation (INS) is higher than the selectivity obtained with electrical stimulation. To obtain more independent channels for stimulation in neural prostheses, INS may be implemented to better restore the fidelity of the damaged neural system. However, irradiation with infrared light also bares the risk of heat accumulation in the target tissue with subsequent neural damage. Lowering the threshold for stimulation could reduce the amount of heat delivered to the tissue and the risk for subsequent tissue damage. It has been shown in the rat sciatic nerve that simultaneous irradiation with infrared light and the delivery of biphasic sub-threshold electrical pulses can reduce the threshold for INS [1]. In this study, deaf white cats have been used to test whether opto-electrical co-stimulation can reduce the stimulation threshold for INS in the auditory system too. The cochleae of the deaf white cats have largely reduced spiral ganglion neuron counts and significant degeneration of the organ of Corti and do not respond to acoustic stimuli. Combined electrical and optical stimulation was used to demonstrate that simultaneous stimulation with infrared light and biphasic electrical pulses can reduce the threshold for stimulation.

  17. A Large Aperture, High Energy Laser System for Optics and Optical Component Testing

    International Nuclear Information System (INIS)

    Nostrand, M.C.; Weiland, T.L.; Luthi, R.L.; Vickers, J.L.; Sell, W.D.; Stanley, J.A.; Honig, J.; Auerbach, J.; Hackel, R.P.; Wegner, P.J.

    2003-01-01

    A large aperture, kJ-class, multi-wavelength Nd-glass laser system has been constructed at Lawrence Livermore National Lab which has unique capabilities for studying a wide variety of optical phenomena. The master-oscillator, power-amplifier (MOPA) configuration of this ''Optical Sciences Laser'' (OSL) produces 1053 nm radiation with shaped pulse lengths which are variable from 0.1-100 ns. The output can be frequency doubled or tripled with high conversion efficiency with a resultant 100 cm 2 high quality output beam. This facility can accommodate prototype hardware for large-scale inertial confinement fusion lasers allowing for investigation of integrated system issues such as optical lifetime at high fluence, optics contamination, compatibility of non-optical materials, and laser diagnostics

  18. Sources of uncertainties in OSL dating of archaeological mortars: The case study of the Roman amphitheatre “Palais-Gallien” in Bordeaux

    International Nuclear Information System (INIS)

    Urbanova, P.; Hourcade, D.; Ney, C.; Guibert, P.

    2015-01-01

    Archaeological mortars are more convenient and much more representative for the chronology of buildings than brick or wood constructions that can be re-used from older buildings. Before dating unknown samples of mortars, further investigation of OSL from mortars is required and the most efficient methodology needs to be established. In this study we compared the ages obtained by OSL dating of quartz extracted from mortars of the Roman amphitheatre Palais-Gallien in Bordeaux with independent age information. Resetting of the OSL signal occurred during the preparation of mortar when grains of sand (quartz) were extracted and mixed with lime and water. The mortar was subsequently hidden from light by embedding within the structure which is the event to be dated. Various factors contribute to uncertainties in the age determination. The frequency of measured equivalent doses reveals a large scattering. Optical bleaching of certain grains can be partial due to the short duration of the exposure to light. We worked with the single grain technique in order to find and select the grains that were sufficiently exposed to daylight. To determine the average equivalent dose, we tried three different approaches: a calculation of an arithmetic mean and one following either the central age model or the 3-parameter minimum age model, the latter turned out to be the only relevant way to evaluate the experimental data. The proportion of grains included in the calculation of the average equivalent dose represents 2.7–4.7 % of the overall analysed grains. The results obtained for the three out of four samples are approaching the expected age, however, the minimum doses and the corresponding ages are significantly over-estimated in case of two samples. The studied material is very coarse, which causes heterogeneity of irradiation at the single grain scale, and contributes to a dispersion of equivalent doses. Different analytical methods (scanning electron microscopy with energy

  19. Retrospective dosimetry using Japanese brick quartz: A way forward despite an unstable fast decaying OSL signal

    DEFF Research Database (Denmark)

    Fujita, Hiroki; Jain, Mayank; Murray, A.S.

    2011-01-01

    signals has been carried out towards identification of common source traps. It is observed that OSL from Japanese brick quartz shows unusual luminescence characteristics; in particular, the initial fast decaying OSL signal contains a dominant (>90%) thermally unstable component related to the 85 °C TL...... peak, which necessitates a prior heat treatment. A single-aliquot regenerative-dose (SAR) protocol is developed and tested using thermal treatments intended to isolate a stable dosimetric signal. A minimum detection limit of 65 mGy is then estimated using this protocol. Following irradiation using 60Co...... of Japanese brick quartz examined here can be used to derive precise estimates of accident dose, and, possibly to distinguish between sources of gamma radiation in a nuclear accident. To our knowledge, this is the first report on the existence of an unstable fast decaying OSL signal in quartz derived from...

  20. A short-time fading study of Al2O3:C

    International Nuclear Information System (INIS)

    Nascimento, L.F.; Vanhavere, F.; Silva, E.H.; Deene, Y. De

    2015-01-01

    This paper studies the short-time fading from Al 2 O 3 :C by measuring optically stimulated luminescence (OSL) signals (Total OSL: T OSL , and Peak OSL: P OSL ) from droplets and Luxel™ pellets. The influence of various bleaching regimes (blue, green and white) and light power is compared. The fading effect is the decay of the OSL signal in the dark at room temperature. Al 2 O 3 :C detectors were submitted to various bleaching regimes, irradiated with a reference dose and read out after different time spans. Investigations were carried out using 2 mm size droplet detectors, made of thin Al 2 O 3 :C powder mixed with a photocured polymer. Tests were compared to Luxel™-type detectors (Landauer Inc.). Short-time post-irradiation fading is present in OSL results (T OSL and P OSL ) droplets for time spans up to 200 s. The effect of short-time fading can be lowered/removed when treating the detectors with high-power and/or long time bleaching regimes; this result was observed in both T OSL and P OSL from droplets and Luxel™. - Highlights: • Droplet composed of thin powder of Al 2 O 3 :C was prepared using a photo-curable polymer. • Powder grain sizes ranged from 5 μm to 35 μm. • Short-time fading was measured for irradiated samples. • Various bleaching regimes and light power was tested. • Droplets were compared to a commercially dosimeter, Luxel™

  1. An integrated optical coherence microscopy imaging and optical stimulation system for optogenetic pacing in Drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Men, Jing; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2016-03-01

    Electrical stimulation is the clinical standard for cardiac pacing. Although highly effective in controlling cardiac rhythm, the invasive nature, non-specificity to cardiac tissues and possible tissue damage limits its applications. Optogenetic pacing of the heart is a promising alternative, which is non-invasive and more specific, has high spatial and temporal precision, and avoids the shortcomings in electrical stimulation. Drosophila melanogaster, which is a powerful model organism with orthologs of nearly 75% of human disease genes, has not been studied for optogenetic pacing in the heart. Here, we developed a non-invasive integrated optical pacing and optical coherence microscopy (OCM) imaging system to control the heart rhythm of Drosophila at different developmental stages using light. The OCM system is capable of providing high imaging speed (130 frames/s) and ultrahigh imaging resolutions (1.5 μm and 3.9 μm for axial and transverse resolutions, respectively). A light-sensitive pacemaker was developed in Drosophila by specifically expressing the light-gated cation channel, channelrhodopsin-2 (ChR2) in transgenic Drosophila heart. We achieved non-invasive and specific optical control of the Drosophila heart rhythm throughout the fly's life cycle (larva, pupa, and adult) by stimulating the heart with 475 nm pulsed laser light. Heart response to stimulation pulses was monitored non-invasively with OCM. This integrated non-invasive optogenetic control and in vivo imaging technique provides a novel platform for performing research studies in developmental cardiology.

  2. Luminescence dating in archaeology

    International Nuclear Information System (INIS)

    Wintle, A.G.

    2001-01-01

    Thermoluminescence (TL) dating is routinely applied to burnt lithic material. Simple fires are capable of enabling stones weighing a few hundred grams to reach 450 o C, thus zeroing the TL signal. TL dates have been obtained for Upper and Lower Paleolithic sites in Europe and the Near East. TL dating continues to be used for dating pottery and for authentification of ceramic works of art. Some recent studies report the use of optically stimulated luminescence (OSL) (also know as photoluminescence) for dating very small samples of quartz, e.g. from small pieces of pottery or frm metallurgical slag The major recent advance has been in the development of a reliable laboratory procedure for using the OSL signal from quartz to obtain the past radiation exposure. The quartz OSL signal is extremely sensitive to light and is reduced to a negligible level on exposure to direct sunlight for radionuclides during burial, signal to date san.sized quartz grains extracted from sediments, The OSL signal is stimulated by 470 nm light from emitting diodes and the detected using flirters centred on 340 nm A similar signal can be obtained from feldspar grain when are exposed to infrared wavelengths around 880 nm. The infrared stimulated luminescence (IRSL) signals is also rapidly depleted by exposure to sunlight, and dating of colluvial deposits from archaeological sites has been reported

  3. Using soils for accident dosimetry: a preliminary study using optically stimulated luminescence from quartz

    DEFF Research Database (Denmark)

    Fujita, Hiroki; Jain, Mayank; Murray, Andrew S.

    2011-01-01

    . The objective was to assess the potential of SAROSL dosimetry using soils for retrospective assessment of a radiation accident. Variation in dose with depth was also measured. The SAR data showed good reproducibility and dose recovery, and there was no evidence of fading of the quartz signal based on “delayed......” dose recovery experiments. The minimum detection limit (MDL) dose was about 0.1Gy. The dose dependence was measured using both the above SAR OSL protocol as well as a SAR thermoluminescence (TL, violet emission) protocol. The background doses were generally in the range of the MDL to several Gy......, and no clear trend in dose depth profile was observed. From these results, we conclude that SAR OSL dosimetry using natural quartz extracted from soil could be used to evaluate the dose of an accident....

  4. Measurement of the dose in quartz in the presence of feldspar contamination

    DEFF Research Database (Denmark)

    Wallinga, J.; Murray, A.S.; Bøtter-Jensen, L.

    2002-01-01

    To allow the determination of the dose in quartz in the presence of feldspar contamination. the quartz-to-feldspar optically stimulated luminescence (OSL) ratio needs to be maximised. Experiments were carried Out to find the optimum procedure to bleach the feldspar by exposure to infrared light...

  5. Journal of Earth System Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Field geomorphology and remote sensing data, supported by Optical Stimulated Luminescence (OSL) dating from the Mandakini river valley of the Garhwal Himalaya enabled identification of four major glacial events; Rambara Glacial Stage (RGS) (13 ± 2 ka), Ghindurpani Glacial Stage (GhGS) (9 ± 1 ka), Garuriya Glacial ...

  6. Advances in luminescence instrument systems

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Bulur, E.; Duller, G.A.T.

    2000-01-01

    We report on recent advances in the development of luminescence measurement systems and techniques at Riso. These include: (1) optical stimulation units based on new-generation powerful blue light (470 nm) emitting diodes providing up to 28 mW/cm(2) for OSL measurements; (2) an infrared (830 nm...

  7. Comparison of single-grain and small-aliquot OSL dose estimates in <3000 years old river sediments from South India

    International Nuclear Information System (INIS)

    Thomas, P.J.; Jain, M.; Juyal, N.; Singhvi, A.K.

    2005-01-01

    We report on OSL dose distributions derived from small-aliquot and single grains of quartz in young fluvial sediments sampled from the Penner River basin, South India. The single-grain dose distributions suggest that 13 out of 19 samples were well bleached. In many well-bleached samples, there was an underestimation in the single-aliquot dose estimates as compared to those from the single grain-the difference between average dose estimates determined by the two methods ranged from ∼1% to 31%. Such a dose underestimation was not detectable in poorly bleached samples. Various possible reasons for the discrepancy between single-grain and small-aliquot dose estimates are discussed. Although there is no satisfactory explanation for this discrepancy, we speculate that the difference in the stimulation wavelengths, 470+/-30nm in the case of single-aliquot and 532nm in the case of single grains, could perhaps be one of the reasons; this may occur because the stimulation wavelength affects the proportion of the medium and slow components in the initial signal

  8. Optical dating and palaeoecological investigations of ancient mud-wasp nests: Progress and prospects in rock art chronometry and palaeoenvironmental reconstructions

    International Nuclear Information System (INIS)

    Roberts, R.G.; Olley, J.M.; Walsh, G.L.; Murray, A.S.; Macphail, M.K.; Bowdery, D.E.; Jones, R.; Naumann, I.D.; Morwood, M.J.

    1997-01-01

    Full text: The spectacular rock art of northern Australia has long fascinated archaeologists but efforts to probe its probable great antiquity have been largely frustrated. Optical dating has been applied recently to ancient mud-wasp nests in the Kimberley region of Western Australia, the optically-stimulated luminescence (OSL) being obtained from quartz grains extracted from the nest mud. These nests overlie and in some places underlie rock paintings, thereby providing a means of constraining the ages of specific art motifs, such as Wandjina and Bradshaw paintings. Also incorporated in the nest mud are pollen grains, spores and phytoliths from which a variety of palaeoecological information has been gleaned and which offer the possibility of direct AMS radiocarbon dating. A summary of the Holocene and late Pleistocene chronological and palaeoenvironmental records obtained so far will be presented, and avenues for future investigation will be discussed

  9. Note: Automated optical focusing on encapsulated devices for scanning light stimulation systems

    International Nuclear Information System (INIS)

    Bitzer, L. A.; Benson, N.; Schmechel, R.

    2014-01-01

    Recently, a scanning light stimulation system with an automated, adaptive focus correction during the measurement was introduced. Here, its application on encapsulated devices is discussed. This includes the changes an encapsulating optical medium introduces to the focusing process as well as to the subsequent light stimulation measurement. Further, the focusing method is modified to compensate for the influence of refraction and to maintain a minimum beam diameter on the sample surface

  10. Luminescence dosemeter of the Al{sub 2}O{sub 3}:Er,Yb

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Katia A.; Ventieri, Alexandre; Bitencourt, Jose F.S. [Universidade de Sao Paulo (EP/USP), SP (Brazil). Escola Politecnica. Dept. de Engenharia Eletrica; Mittani, Juan C.R.; Tatumi, Sonia H. [Faculdade de Tecnologia de Sao Paulo (CEETEPS), SP (Brazil)

    2011-07-01

    The present work deals with the thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) properties of {alpha}-Al{sub 2}O{sub 3}: Er,Yb obtained by sol gel process. Nanocrystals formations composed by Er{sub 2}O{sub 3}, Yb{sub 2}O{sub 3} and Yb{sub 3}Al{sub 5}O{sub 12} were observed by TEM images, EDS, electron beam diffraction and RXD, located at the surface of the alumina grains. The sample codoped with 1mol% of Er and 2 mol% of Yb supplied the best results for TL and OSL responses. The growth of the intensity of dosimetric TL peak at 205 deg C was linear with gamma radiation doses and the same behavior was observed in OSL growth curve. The luminescence fading of the sample after a dose of 5 Gy was found initially for a period of 30 days and minimum detectable dose measured for TL was 60.78 mGy and for OSL was 13.09 mGy. (author)

  11. AlN ceramics as a detector for UV exposure

    International Nuclear Information System (INIS)

    Trinkler, L.; Berzina, B.; Boetter-Jensen, L.; Christensen, P.; Palcevskis, E.

    1999-01-01

    AlN-Y 2 O 3 ceramics is proposed for application in the field of UV detection and dosimetry. Both thermoluminescence (TL) and optically stimulated luminescence (OSL) signals from the material have been studied after exposure to UV light. AlN-Y 2 O 3 ceramics demonstrates very high sensitivity to UV light over a broad spectral region. The TL is characterized by a linear dose dependence over a large range. The fading rate of the UV-induced TL and OSL signals on storage at room temperature is lower than in the case of exposure to ionizing irradiation. (au)

  12. Luminescence property of volcanic quartz and the use of red isothermal TL for dating tephras

    International Nuclear Information System (INIS)

    Tsukamoto, S.; Murray, A.S.; Huot, S.; Watanuki, T.; Denby, P.M.; Botter-Jensen, L.

    2007-01-01

    An optically stimulated luminescence (OSL) age obtained from a Japanese tephra using quartz phenocrysts severely underestimated the known age. The characteristics of the OSL signals were investigated in order to understand the cause of the underestimation; the main OSL component of volcanic quartz has a thermodynamic lifetime of about 1700 years at room temperature, and it also seems to fade anomalously (i.e. athermally). Measurement of conventional red thermoluminescence (RTL) using a Ga-As photomultiplier tube was difficult due to the presence of a strong thermal background, although RTL gave an age consistent with the independent age. Furthermore, red isothermal TL (RITL) at 380 deg. C allowed the RTL signal to be separated from to the thermal background, and RITL ages of three volcanic quartz samples show good agreement with independent ages

  13. A Programmable Optical Stimulator for the Drosophila Eye.

    Science.gov (United States)

    Chen, Xinping; Leon-Salas, Walter D; Zigon, Taylor; Ready, Donald F; Weake, Vikki M

    2017-10-01

    A programmable optical stimulator for Drosophila eyes is presented. The target application of the stimulator is to induce retinal degeneration in fly photoreceptor cells by exposing them to light in a controlled manner. The goal of this work is to obtain a reproducible system for studying age-related changes in susceptibility to environmental ocular stress. The stimulator uses light emitting diodes and an embedded computer to control illuminance, color (blue or red) and duration in two independent chambers. Further, the stimulator is equipped with per-chamber light and temperature sensors and a fan to monitor light intensity and to control temperature. An ON/OFF temperature control implemented on the embedded computer keeps the temperature from reaching levels that will induce the heat shock stress response in the flies. A custom enclosure was fabricated to house the electronic components of the stimulator. The enclosure provides a light-impermeable environment that allows air flow and lets users easily load and unload fly vials. Characterization results show that the fabricated stimulator can produce light at illuminances ranging from 0 to 16000 lux and power density levels from 0 to 7.2 mW/cm 2 for blue light. For red light the maximum illuminance is 8000 lux which corresponds to a power density of 3.54 mW/cm 2 . The fans and the ON/OFF temperature control are able to keep the temperature inside the chambers below 28.17°C. Experiments with white-eye male flies were performed to assess the ability of the fabricated simulator to induce blue light-dependent retinal degeneration. Retinal degeneration is observed in flies exposed to 8 hours of blue light at 7949 lux. Flies in a control experiment with no light exposure show no retinal degeneration. Flies exposed to red light for the similar duration and light intensity (8 hours and 7994 lux) do not show retinal degeneration either. Hence, the fabricated stimulator can be used to create environmental ocular stress

  14. A programmable optical stimulator for the Drosophila eye

    Directory of Open Access Journals (Sweden)

    Xinping Chen

    2017-10-01

    Full Text Available A programmable optical stimulator for Drosophila eyes is presented. The target application of the stimulator is to induce retinal degeneration in fly photoreceptor cells by exposing them to light in a controlled manner. The goal of this work is to obtain a reproducible system for studying age-related changes in susceptibility to environmental ocular stress. The stimulator uses light emitting diodes and an embedded computer to control illuminance, color (blue or red and duration in two independent chambers. Further, the stimulator is equipped with per-chamber light and temperature sensors and a fan to monitor light intensity and to control temperature. An ON/OFF temperature control implemented on the embedded computer keeps the temperature from reaching levels that will induce the heat shock stress response in the flies. A custom enclosure was fabricated to house the electronic components of the stimulator. The enclosure provides a light-impermeable environment that allows air flow and lets users easily load and unload fly vials. Characterization results show that the fabricated stimulator can produce light at illuminances ranging from 0 to 16000 lux and power density levels from 0 to 7.2 mW/cm2 for blue light. For red light the maximum illuminance is 8000 lux which corresponds to a power density of 3.54 mW/cm2. The fans and the ON/OFF temperature control are able to keep the temperature inside the chambers below 28.17 °C. Experiments with white-eye male flies were performed to assess the ability of the fabricated simulator to induce blue light-dependent retinal degeneration. Retinal degeneration is observed in flies exposed to 8 h of blue light at 7949 lux. Flies in a control experiment with no light exposure show no retinal degeneration. Flies exposed to red light for the similar duration and light intensity (8 h and 7994 lux do not show retinal degeneration either. Hence, the fabricated stimulator can be used to create environmental

  15. To the problem of paleodosimetrical information stability in alkali feldspars

    International Nuclear Information System (INIS)

    Huett, Galina; Jaek, Ivar

    1997-01-01

    The stability of holes of the centres of recombination in alkali feldspars, extracted from sediments, is studied. For the emission centres with 410 and 570 nm the energy of activation of thermal quenching is obtained (> 2 eV). Problems of fading and difference between thermoluminescence (TL) and optically stimulated luminescence (OSL), as well as bleach abilities, are discussed. Values of thermal activation energy (> 2 eV) obtained for two different emission bands (410 and 570 nm) in alkali feldspars prove the upper limit of dating (c 10 5 years). The absence of a permanent channel of fading is supported by experimental data. Differences in bleach ability, as well as in residuals of TL and OSL response dating signals, are explained within the frame of the proposed model of identity of defects responsible for those signals. It is supposed that better bleach ability of the OSL signal is connected with optical selection of more transparent grains (or more easily bleach able centres). The applicability of the orange band of emission (570 nm) for dating is recommended for future study

  16. Personal dosimetry service of VF, a.s. company

    International Nuclear Information System (INIS)

    Prasek, P.

    2009-01-01

    The VF, a.s. Company will extend its services in the area of personal dosimetry at the end of 2008, which is fully in compliance with the requirements of the Atomic Act, section 9 paragraph (1) letter r) and Decree on Radiation Protection, section 59 paragraph (1) letter a). Optically stimulated luminescence was selected in VF .a.s. as the most advantageous and the most advanced technology for the integral personal dosimetry. Optically stimulated luminescence (OSL) has been using in dosimetry for more than ten years. Although it is relatively new technology , its indisputable advantages predetermine that technology has significantly benefited in personal dosimetry services within a short time all over the advanced world. The VF, a.s. personal dosimetry service is based on the licensed products of LANDAUER, the US company, which is the world leader in OSL dosimetry. Crystalline Al 2 O 3 :C was selected as the detection material. All equipment of personal dosimetry service is installed in the VF Centre of Technology in Cerna Hora. The personal dosimetry service is incorporated in the International LANDAUER Dosimetry Service Network, and in the European Union, it is directly linked to the LANDAUER European Headquarters with its office in Paris. As a part of the OSL technology licence, the VF personal dosimetry service was included in the inter-laboratory comparison programme of the LANDAUER syndicate. (author)

  17. Personal dosimetry service of VF, a.s. company

    International Nuclear Information System (INIS)

    Prasek, P.

    2008-01-01

    The VF, a.s. Company will extend its services in the area of personal dosimetry at the end of 2008, which is fully in compliance with the requirements of the Atomic Act, section 9 paragraph (1) letter r) and Decree on Radiation Protection, section 59 paragraph (1) letter a). Optically stimulated luminescence was selected in VF .a.s. as the most advantageous and the most advanced technology for the integral personal dosimetry . Optically stimulated luminescence (OSL) has been using in dosimetry for more than ten years. Although it is relatively new technology , its indisputable advantages predetermine that technology has significantly benefited in personal dosimetry services within a short time all over the advanced world. The VF, a.s. personal dosimetry service is based on the licensed products of LANDAUER, the US company, which is the world leader in OSL dosimetry. Crystalline Al 2 O 3 :C was selected as the detection material. All equipment of personal dosimetry service is installed in the VF Centre of Technology in Cerna Hora. The personal dosimetry service is incorporated in the International LANDAUER Dosimetry Service Network, and in the European Union, it is directly linked to the LANDAUER European Headquarters with its office in Paris. As a part of the OSL technology licence, the VF personal dosimetry service was included in the inter-laboratory comparison programme of the LANDAUER syndicate. (author)

  18. A family of neuromuscular stimulators with optical transcutaneous control.

    Science.gov (United States)

    Jarvis, J C; Salmons, S

    1991-01-01

    A family of miniature implantable neuromuscular stimulators has been developed using surface-mounted Philips 4000-series integrated circuits. The electronic components are mounted by hand on printed circuits (platinum/gold on alumina) and the electrical connections are made by reflow soldering. The plastic integrated-circuit packages, ceramic resistors and metal interconnections are protected from the body fluids by a coating of biocompatible silicone rubber. This simple technology provides reliable function for at least 4 months under implanted conditions. The circuits have in common a single lithium cell power-supply (3.2 V) and an optical sensor which can be used to detect light flashes through the skin after the device has been implanted. This information channel may be used to switch the output of a device on or off, or to cycle through a series of pre-set programs. The devices are currently finding application in studies which provide an experimental basis for the clinical exploitation of electrically stimulated skeletal muscle in cardiac assistance, sphincter reconstruction or functional electrical stimulation of paralysed limbs.

  19. Optical parametric amplification and oscillation assisted by low-frequency stimulated emission.

    Science.gov (United States)

    Longhi, Stefano

    2016-04-15

    Optical parametric amplification and oscillation provide powerful tools for coherent light generation in spectral regions inaccessible to lasers. Parametric gain is based on a frequency down-conversion process and, thus, it cannot be realized for signal waves at a frequency ω3 higher than the frequency of the pump wave ω1. In this Letter, we suggest a route toward the realization of upconversion optical parametric amplification and oscillation, i.e., amplification of the signal wave by a coherent pump wave of lower frequency, assisted by stimulated emission of the auxiliary idler wave. When the signal field is resonated in an optical cavity, parametric oscillation is obtained. Design parameters for the observation of upconversion optical parametric oscillation at λ3=465 nm are given for a periodically poled lithium-niobate (PPLN) crystal doped with Nd(3+) ions.

  20. Real-time in vivo luminescence dosimetry in radiotherapy and mammography using Al{sub 2}O{sub 3}:C

    Energy Technology Data Exchange (ETDEWEB)

    Aznar, M.C.

    2005-06-15

    New treatment and clinical imaging techniques have created a need for accurate and practical in vivo dosimeters in radiation medicine. This work describes the development of a new optical-fiber radiation dosimeter system, based on radioluminescence (RL) and optically stimulated luminescence (OSL) from carbon-doped aluminium oxide (Al2O3:C), for applications in radiotherapy and mammography. This system offers several features, such as a small detector, high sensitivity, real-time read-out, and the ability to measure both dose rate and absorbed dose. Measurement protocols and algorithms for the correction of responses were developed to enable a reliable absorbed dose assessment from the RL and OSL signals. At radiotherapy energies, the variation of the signal with beam parameters was smaller than 1% (1 SD). Treatment-like experiments in phantoms, and in vivo measurements during complex patient treatments (such as intensity-modulated radiation therapy) indicate that the RL/OSL dosimetry system can reliably measure the absorbed dose within 2%. The real-time RL signal also enables an individual dose assessment from each field. The RL/OSL dosimetry system was also used during mammography examinations. In such conditions, the reproducibility of the measurements showed to be around 3%. In vivo measurements on three patients showed that the presence of the RL/OSL probes did not degrade the diagnostic quality of the radiograph and that the system could be used to measure exit doses (i.e., absorbed doses on the inferior surface of the breast). A Monte Carlo study proved that the energy dependence of the RL/OSL system at these low energies could be reduced by optimizing the design of the probes. It is concluded that the new RL/OSL dosimetry system shows considerable potential for applications in both radiotherapy and mammography. (au)

  1. Real-time in vivo luminescence dosimetry in radiotherapy and mammography using Al2O3:C

    International Nuclear Information System (INIS)

    Aznar, M.C.

    2005-07-01

    New treatment and clinical imaging techniques have created a need for accurate and practical in vivo dosimeters in radiation medicine. This work describes the development of a new optical-fiber radiation dosimeter system, based on radioluminescence (RL) and optically stimulated luminescence (OSL) from carbon-doped aluminium oxide (Al2O3:C), for applications in radiotherapy and mammography. This system offers several features, such as a small detector, high sensitivity, real-time read-out, and the ability to measure both dose rate and absorbed dose. Measurement protocols and algorithms for the correction of responses were developed to enable a reliable absorbed dose assessment from the RL and OSL signals. At radiotherapy energies, the variation of the signal with beam parameters was smaller than 1% (1 SD). Treatment-like experiments in phantoms, and in vivo measurements during complex patient treatments (such as intensity-modulated radiation therapy) indicate that the RL/OSL dosimetry system can reliably measure the absorbed dose within 2%. The real-time RL signal also enables an individual dose assessment from each field. The RL/OSL dosimetry system was also used during mammography examinations. In such conditions, the reproducibility of the measurements showed to be around 3%. In vivo measurements on three patients showed that the presence of the RL/OSL probes did not degrade the diagnostic quality of the radiograph and that the system could be used to measure exit doses (i.e., absorbed doses on the inferior surface of the breast). A Monte Carlo study proved that the energy dependence of the RL/OSL system at these low energies could be reduced by optimizing the design of the probes. It is concluded that the new RL/OSL dosimetry system shows considerable potential for applications in both radiotherapy and mammography. (au)

  2. The timing of sediment transport down Monterey Submarine Canyon, offshore California

    DEFF Research Database (Denmark)

    Stevens, Thomas; Paull, C.K.; Ussler, W., III

    2014-01-01

    luminescence (OSL) ages of quartz sand deposits and accelerator mass spectrometry 14C ages measured on benthic foraminifera to examine the timing of sediment transport through the axial channel of Monterey Submarine Canyon and Fan, offshore California. The OSL ages date the timing of sediment entry...... dates with water depth provides evidence of mixing and temporary storage of sediment as it moves through the canyon system. The ages also indicate that the frequency of sediment transport events decreases with distance down the canyon channel system. The amalgamated sands near the canyon head yield OSL......While submarine canyons are the major conduits through which sediments are transported from the continents out into the deep sea, the time it takes for sediment to pass down through a submarine canyon system is poorly constrained. Here we report on the first study to couple optically stimulated...

  3. Optical path of infrared neural stimulation in the guinea pig and cat cochlea

    Science.gov (United States)

    Rajguru, Suhrud M.; Hwang, Margaret; Moreno, Laura E.; Matic, Agnella I.; Stock, Stuart R.; Richter, Claus-Peter

    2011-03-01

    It has been demonstrated previously that infrared neural stimulation (INS) can be used to stimulate spiral ganglion cells in the cochlea. With INS, neural stimulation can be achieved without direct contact of the radiation source and the tissue and is spatially well resolved. The presence of fluids or bone between the target structure and the radiation source may lead to absorption or scattering of the radiation and limit the efficacy of INS. To develop INS based cochlear implants, it is critical to determine the beam path of the radiation in the cochlea. In the present study, we utilized noninvasive X-ray microtomography (microCT) to visualize the orientation and location of the optical fiber within the guinea pig and cat cochlea. Overall, the results indicated that the optical fiber was directed towards the spiral ganglion cells in the cochlea and not the nerve fibers in the center of the modiolus. The fiber was approximately 300 μm away from the target structures. In future studies, results from the microCT will be correlated with physiology obtained from recordings in the midbrain.

  4. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors

    International Nuclear Information System (INIS)

    Karsch, L.; Beyreuther, E.; Burris-Mog, T.; Kraft, S.; Richter, C.; Zeil, K.; Pawelke, J.

    2012-01-01

    Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10 11 Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410 9 Gy/s within 2% (OSL and TLD) and up to 1510 9 Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.

  5. Bulletin of Materials Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    In contrast to the conventional DSSC systems, where the dye molecules are used as light harvesting material, here a solid-state absorber was used as a sensitizer in conjunction with the dye. The materials like ZnO and Al2O3 : C, which will show optically stimulated luminescence (OSL) upon irradiation were used as ...

  6. Constraining the age of rock art by dating a rockfall event using sediment and rock-surface luminescence dating techniques

    DEFF Research Database (Denmark)

    Chapot, Melissa; Sohbati, Reza; Murray, A.S.

    2012-01-01

    Optically stimulated luminescence (OSL) is used to determine the age of a rockfall event that removed part of the pictograph figures at the Great Gallery rock art panel in Canyonlands National Park, Utah, USA. Analyses from the outer millimeter of the buried surface of a rockfall boulder and quartz...... rock art with a controversial and unknown origin....

  7. A new flexible system for measuring thermally and optically stimulated luminescence

    DEFF Research Database (Denmark)

    Markey, B.G.; Bøtter-Jensen, L.; Duller, G.A.T.

    1997-01-01

    . New hardware features include a two-speed sample turntable, a new detachable beta irradiator with a Be window vacuum interface and the incorporation of an on-board minicomputer.,A completely new software concept was developed that allows the user unlimited control of the reader and has, at the same......The automated Riso TL/OSL reader system is used worldwide for luminescence dating, retrospective dosimetry environmental dosimetry and material characterization. In response to requests from many users we have re-designed the reader by incorporating a variety of new hardware and software features...

  8. TL/OSL ages from Salto Formation (Uruguay)tectonic, climatic and environmental considerations

    International Nuclear Information System (INIS)

    Ubilla, M.; Veroslavsky, G.

    2004-01-01

    TL/OSL ages from Salto Formation based on two sandy samples collected at Salto City and Route 3 (Boycua Creek) are provided: 986±100 ky (LVD-948) and 830±95 ky (LVD-949) respectively. Both support a Pleistocene age for Salto Formation, approximately late early/early middle Pleistocene. Neotectonic and climatic processes are also discussed [es

  9. OSL sensitivity changes during single aliquot procedures: Computer simulations

    DEFF Research Database (Denmark)

    McKeever, S.W.S.; Agersnap Larsen, N.; Bøtter-Jensen, L.

    1997-01-01

    We present computer simulations of sensitivity changes obtained during single aliquot, regeneration procedures. The simulations indicate that the sensitivity changes are the combined result of shallow trap and deep trap effects. Four separate processes have been identified. Although procedures can...... be suggested to eliminate the shallow trap effects, it appears that the deep trap effects cannot be removed. The character of the sensitivity changes which result from these effects is seen to be dependent upon several external parameters, including the extent of bleaching of the OSL signal, the laboratory...

  10. SBS [stimulated Brillouin scattering] pulse distortion in multimode optical fibers

    International Nuclear Information System (INIS)

    Smith, J.R.; Hawkins, R.J.; Laumann, C.W.; Hatch, J.

    1989-01-01

    We have observed sever temporal-pulse-shape distortion due to stimulated Brillouin scattering (SBS) in multimode optical fibers used to diagnose 351 m laser pulses on the Nova laser system. Our measurements can be fit by a basic model of SBS and provide a clear indication of the intensity and temporal regimes where significant SBS-induced temporal-pulse-shape distortion can be avoided. 15 refs., 3 figs., 1 tab

  11. Fiber-coupled radioluminescence dosimetry with saturated Al2O3:C crystals: Characterization in 6 and 18 MV photon beams

    DEFF Research Database (Denmark)

    Andersen, Claus Erik; Damkjær, Sidsel Marie Skov; Kertzscher Schwencke, Gustavo Adolfo Vladimir

    2011-01-01

    Radioluminescence (RL) and optically stimulated luminescence (OSL) from carbon-doped aluminum oxide crystals can be used for medical dosimetry in external beam radiotherapy and remotely afterloaded brachytherapy. The RL/OSL signals are guided from the treatment room to the readout instrumentation...... using optical fiber cables, and in vivo dosimetry can be carried out in real time while the dosimeter probes are in the patient. The present study proposes a new improved readout protocol based solely on the RL signal from Al2O3:C. The key elements in the protocol are that Al2O3:C is pre-dosed with 20...... ((−0.21 ± 0.01)%/ °C), and dose-delivery rate ((−0.22 ± 0.01)% per 100 MU/min). A temporal gating technique was used for separation of RL and stem signals (i.e. Cerenkov light and fluorescence induced in the optical fiber cable during irradiation). The new readout protocol was a substantial improvement...

  12. A luminescence imaging system for the routine measurement of single-grain OSL dose distributions

    DEFF Research Database (Denmark)

    Kook, Myung Ho; Lapp, Torben; Murray, Andrew

    2015-01-01

    the potential of an electron multiplying charge-coupled device (EMCCD), providing extremely low level light detection. We characterize the performance of the device by discussing reproducibility and evaluating uncertainties in OSL signals. Finally we derive a typical single grain natural dose distribution...

  13. Efficient trigger signal generation from wasted backward amplified stimulated emission at optical amplifiers for optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Kim Seung Taek

    2015-01-01

    Full Text Available This paper propose an optical structure to generate trigger signals for optical coherence tomography (OCT using backward light which is usually disposed. The backward light is called backward amplified stimulated emission generated from semiconductor optical amplifier (SOA when using swept wavelength tunable laser (SWTL. A circulator is applied to block undesirable lights in the SWTL instead of an isolator in common SWTL. The circulator also diverts backward amplified spontaneous lights, which finally bring out trigger signals for a high speed digitizer. The spectra of the forward lights at SOA and the waveform of the backward lights were measured to check the procedure of the trigger formation in the experiment. The results showed that the trigger signals from the proposed SWTL with the circulator was quite usable in OCT.

  14. Direct and indirect dating of gypsum occurrences in deserts using luminescence methods

    International Nuclear Information System (INIS)

    Nagar, Y.C.; Juyal, N.; Singhyi, A.K.; Kocurek, G.; Wadhawan, S.K.

    2005-01-01

    In the present study we have made an attempt to directly date gypsum or provide indirect age estimate for gypsum formation through dating the associated sediments (quartz) using the luminescence dating technique. In the direct dating of gypsum, we explored the Optically Stimulated Luminescence (OSL) and Thermally Stimulated Luminescence (TL) behaviour of gypsum. The associated sediments (indirect dating) were dated using the traces of quartz extract from gypsum (concentration 0.1% ) and the underlying and overlying quartz sand in playa

  15. Implementation of a new personal dosimetry service by the French Army

    International Nuclear Information System (INIS)

    Perks, C.A.; Castagnet, X.

    2006-01-01

    This paper will describe the motivation of the Service de Protection Radiologique des Armees (S.P.R.A.) for replacing their existing dosimetry service based on photographic films with one centralized at Clamart, near Paris, and adopting dosemeters based on Optically Stimulated Luminescence (O.S.L.). The advantages of centralization and of the new technology adopted will be discussed. (authors)

  16. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    Directory of Open Access Journals (Sweden)

    Diego R.G. Tudela

    2012-06-01

    Full Text Available This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at "Luz" Monastery, located in the state of São Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments.Este artigo apresenta os resultados de datação por TL e OSL de solos, e fragmentos de tijolos de um túmulo, que foi ocupado por duas freiras mumificadas encontradas no Mosteiro da "Luz", localizado no Estado de São Paulo, Brasil. As idades encontradas por TL e OSL foram comparadas às obtidas a partir de C-14 dos colágenos contidos em amostras de osso das múmias. A maioria das idades obtidas são do século XVIII. A espectroscopia de radiação-gama foi utilizada para avaliar concentrações de radioisótopos naturais nas amostras e para calcular as taxas de dose anual que resultaram em 3,0 a 5,3 Gy/kano. As concentrações radioativas são próximas daquelas obtidas através de Análise por Ativação de Nêutrons. Os conteúdos de elementos U, Th e Ce são superiores aos encontrados na maioria dos sedimentos.

  17. Violet stimulated luminescence: geo- or thermochronometer?

    DEFF Research Database (Denmark)

    Ankjærgaard, Christina; Guralnik, Benny; Porat, N.

    2015-01-01

    , with a dose saturation level ~20 times higher compared to that of OSL, excellent thermal stability on the 1011 year time scale, and agreement between VSL and OSL ages up to ~0.3 Ma. Here we explore the usability of the VSL signal to date older quartz samples from palaeosols, whose ages are bracketed by Ke...

  18. State of the art of solid state dosimetry

    International Nuclear Information System (INIS)

    Souza, Susana O.; Yamamoto, Takayoshi; D'Errico, Francesco

    2014-01-01

    Passive solid-state detectors still dominate the personal dosimetry field. This article provides state of the art in this field and summarizes the most recent works presented on TL, OSL and RPL during the 17th International Conference on Solid State Dosimetry held in Recife in September 2013. The Article contains in particular the techniques Thermoluminescence (TL), Optically Stimulated Luminescence (OSL), radio photoluminescence (RPL). Thermoluminescence has the biggest advantage of the wide availability of commercial materials for dosimetry, and the nature tissue-equivalent of several of these materials. The limitation of the TL dosimetry presents fading luminance signal and the need for high temperatures to obtain the signal. The Optically Stimulated Luminescence has the advantages of high sensitivity, the possibility of multiple reading, while its limit is the need to use response compensating filters in addition to the high cost of equipment and dosimeters still restricted very few options trading . The radio photoluminescence has a reading that is completely non-destructive, but their dosimeters present lack of tissue-equivalent and a high cost. Presents the details of the techniques and the advantages and limitations of each of these will be discussed

  19. State of the art of solid state dosimetry; Estado da arte em dosimetria do estado solido

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Susana O., E-mail: sosouza@ufs.br [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil); Yamamoto, Takayoshi [Radioisotope Research Center, Osaka University (Japan); D' Errico, Francesco, E-mail: francesco.derrico@yale.edu [Yale University, School of Medicine, CT (United States)

    2014-07-01

    Passive solid-state detectors still dominate the personal dosimetry field. This article provides state of the art in this field and summarizes the most recent works presented on TL, OSL and RPL during the 17th International Conference on Solid State Dosimetry held in Recife in September 2013. The Article contains in particular the techniques Thermoluminescence (TL), Optically Stimulated Luminescence (OSL), radio photoluminescence (RPL). Thermoluminescence has the biggest advantage of the wide availability of commercial materials for dosimetry, and the nature tissue-equivalent of several of these materials. The limitation of the TL dosimetry presents fading luminance signal and the need for high temperatures to obtain the signal. The Optically Stimulated Luminescence has the advantages of high sensitivity, the possibility of multiple reading, while its limit is the need to use response compensating filters in addition to the high cost of equipment and dosimeters still restricted very few options trading . The radio photoluminescence has a reading that is completely non-destructive, but their dosimeters present lack of tissue-equivalent and a high cost. Presents the details of the techniques and the advantages and limitations of each of these will be discussed.

  20. Tests and foreseen developments of fibered-OSLD gamma heating measurements in low-power reactors

    Science.gov (United States)

    Gruel, A.; Guillou, M. Le; Blaise, P.; Destouches, C.; Magne, S.

    2018-01-01

    In this paper are presented test measurements of a fibered-OSLD system performed during a dedicated experimental phase in EOLE zero-power reactor. The measurement setup consists of an OSLD crystal connected onto the extremity of an optical fiber and a laser stimulation system, manufactured by the CEA/LIST in Saclay. The OSL sensor is remotely stimulated via an optical fiber using a diode-pumped solid-state laser. The OSL light is collected and guided back along the same fiber to a photomultiplier tube. Results obtained using this system are compared to usual gamma heating measurement protocol using OSLD pellets. The presence of induced radio-luminescence in the OSLD during the irradiation was also observed and could be used to monitor the gamma flux. The feasibility of remote measurements is achieved, whereas further developments could be conducted to improve this technique since the readout procedure still requires to withdraw the OSLD off the gamma flux (hence from the core) on account of the dose rate (around a few Gy.h-1), and the readout time remains quite long for on-line applications. Several improvements are foreseen, and will be tested in the forthcoming years.

  1. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    International Nuclear Information System (INIS)

    Tudela, Diego R.G.; Tatumi, Sonia H.; Yee, Marcio; Brito, Silvio L.M.

    2012-01-01

    This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at 'Luz' Monastery, located in the state of Sao Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments. (author)

  2. Changes in optically stimulated luminescent dosimeter (OSLD) dosimetric characteristics with accumulated dose

    International Nuclear Information System (INIS)

    Jursinic, Paul A.

    2010-01-01

    Purpose: A new type of in vivo dosimeter, an optically stimulated luminescent dosimeter (OSLD), has now become commercially available for clinical use. The OSLD is a plastic disk infused with aluminum oxide doped with carbon (Al 2 O 3 :C). Crystals of Al 2 O 3 :C, when exposed to ionizing radiation, store energy that is released as luminescence (420 nm) when the OSLD is illuminated with stimulation light (540 nm). The intensity of the luminescence depends on the dose absorbed by the OSLD and the intensity of the stimulation light. The effects of accumulated dose on OSLD response were investigated. Methods: The OSLDs used in this work were nanodot dosimeters, which were read with a MicroStar reader (Landauer, Inc., Glenwood, IL). Dose to the OSLDs was delivered by 6 MV x rays and gamma rays from Co-60 and Ir-192. The signal on the OSLDs after irradiation is removed by optical annealing with a 150 W tungsten-halogen lamp or a 14 W compact fluorescent lamp was investigated. Results: It was found that OSLD response to dose was supralinear and this response was altered with the amount of accumulated dose to the OSLD. The OSLD response can be modeled by a quadratic and an exponential equation. For accumulated doses up to 60 Gy, the OSLD sensitivity (counts/dose) decreases and the extent of supralinear increases. Above 60 Gy of accumulated dose the sensitivity increases and the extent of supralinearity decreases or reaches a plateau, depending on how the OSLDs were optically annealed. With preirradiation of OSLDs with greater than 1 kGy, it is found that the sensitivity reaches a plateau 2.5 folds greater than that of an OSLD with no accumulated dose and the supralinearity disappears. A regeneration of the luminescence signal in the dark after full optical annealing occurs with a half time of about two days. The extent of this regeneration signal depends on the amount of accumulated dose. Conclusions: For in vivo dosimetric measurements, a precision of ±0.5% can be

  3. Applicability of the Sunna dosimeter for food irradiation control

    International Nuclear Information System (INIS)

    Kovacs, A.; Baranyai, M.; Wojnarovits, L.; Miller, S.; Murphy, M.; McLaughlin, W.L.; Slezsak, I.; Kovacs, A.I.

    2002-01-01

    The quick development concerning the commercial application of food irradiation in the USA recently resulted in growing marketing of irradiated red meat as well as irradiated fresh and dried fruits. These gamma and electron irradiation technologies require specific dosimetry systems for process control. The new version of the Sunna dosimeter has been characterized in gamma, electron and bremsstrahlung radiation fields by measuring the optically stimulated luminescence (osl) at 530 nm both below and above 1 kGy, i.e. for disinfestation and for meat irradiation purposes. No humidity and no significant dose rate effect on the green osl signal was observed. The temperature coefficient was determined from 0 deg. C up to about 40 deg. C and to stabilize the osl signal after irradiation a heat treatment method was introduced. Based on these investigations the Sunna 'gamma' film is a suitable candidate for dose control below and above 1 kGy for food irradiation technologies

  4. Synthesis and luminescence properties of KSrPO{sub 4}:Eu{sup 2+} phosphor for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Palan, C. B., E-mail: chetanpalan27@yahoo.in [Department of Physics, Sant Gadge Baba Amravati University, Amravati-444602 (India); Bajaj, N. S. [Toshniwal ACS College, Sengaon, Hingoli-431542 (India); Omanwar, S. K.

    2016-05-06

    The KSrPO{sub 4}:Eu phosphor was synthesized via solid state method. The structural and morphological characterizations were done through XRD (X-ray diffraction) and SEM (Scanning Electronic Microscope). Additionally, the photoluminescence (PL), thermoluminescence (TL) and optically Stimulated luminescence (OSL) properties of powder KSrPO{sub 4}:Eu were studied. The PL spectra show blue emission under near UV excitation. It was advocated that KSrPO{sub 4}:Eu phosphor not only show OSL sensitivity (0.47 times) but also gives faster decay in OSL signals than that of Al{sub 2}O{sub 3}:C (BARC) phosphor. The TL glow curve consist of two shoulder peaks and the kinetics parameters such as activation energy and frequency factors were determined by using peak shape method and also photoionization cross-sections of prepared phosphor was calculated. The radiation dosimetry properties such as minimum detectable dose (MDD), dose response and reusability were reported.

  5. Reproducibility of optically stimulated luminescence measurements from single grains of Al2O3: C and annealed quartz

    DEFF Research Database (Denmark)

    Truscott, A.J.; Duller, G.A.T.; Bøtter-Jensen, L.

    2000-01-01

    of nine-by-nine holes, which are drilled in the sample disc, We report on tests carried out to determine the precision with which the laser beam can be directed at individual grains in these holes. Single grains of aluminium oxide (Al2O3:C) (90-180 mum) and annealed quartz (90-120 mum) were used to test...... the reproducibility with which the OSL signal can be measured. These experiments suggest that the laser beam can be positioned to within 30 mum and that the reproducibility of OSL measurement is 3.5% on an average. (C) 2000 Elsevier Science Ltd. All rights reserved....

  6. Optics in engineering education: stimulating the interest of first-year students

    Science.gov (United States)

    Blanco-García, Jesús; Vazquez-Dorrío, Benito

    2014-07-01

    The work here presented deals with stimulating the interest for optics in first-year students of an Engineering School, which are not specifically following Optical Engineering studies. Optic-based technologies are nowadays wide spread, and growing, in almost all the engineering fields (from non destructive testing or alignments to power laser applications, fiber optic communications, memory devices, etc.). In general, the first year curriculum doesn't allow a detailed review of the main light properties, least its technical applications. We present in this paper our experience in showing some basic optic concepts and related technologies to the students of our school. Based on the fact that they have a very basic training in this branch of physics, we have designed a series of experimental demonstrations with the dual purpose of making them understand the basic principles of these technologies, and to know the potential of applications to engineering they offer. We assembled these experiments in the laboratory and invited students to pass to get to know them, giving them an explanation in which we focused on the possible range of application of each technique. The response was very good, not only by the number of students who attended the invitation but also by the interest demonstrated by their questions and opinions.

  7. Fiber break location technique utilizing stimulated Brillouin scattering effects in optical fiber

    International Nuclear Information System (INIS)

    Bakar, A A A; Al-Mansoori, M H; Mahdi, M A; Mohd Azau, M A; Zainal Abidin, M S

    2009-01-01

    A new technique of fiber break detection system in optical communication networks is proposed and experimentally demonstrated in this paper. This technique is based-on continuous wave light source rather than pulsed source that is commonly deployed in existing techniques. The nonlinear effect of stimulated Brillouin scattering is manipulated to locate the fiber-break position in optical communication networks. This technique enables the utilization of a less-sensitive photodetector to detect the Brillouin Stokes line since its intensity increases with the fiber length in the detectable region. The fiber break location can be determined with accuracy of more than 98% for fiber length less than 50 km using this technique

  8. Computerised curve deconvolution of TL/OSL curves using a popular spreadsheet program.

    Science.gov (United States)

    Afouxenidis, D; Polymeris, G S; Tsirliganis, N C; Kitis, G

    2012-05-01

    This paper exploits the possibility of using commercial software for thermoluminescence and optically stimulated luminescence curve deconvolution analysis. The widely used software package Microsoft Excel, with the Solver utility has been used to perform deconvolution analysis to both experimental and reference glow curves resulted from the GLOw Curve ANalysis INtercomparison project. The simple interface of this programme combined with the powerful Solver utility, allows the analysis of complex stimulated luminescence curves into their components and the evaluation of the associated luminescence parameters.

  9. Computerised curve deconvolution of TL/OSL curves using a popular spreadsheet program

    International Nuclear Information System (INIS)

    Afouxenidis, D.; Polymeris, G. S.; Tsirliganis, N. C.; Kitis, G.

    2012-01-01

    This paper exploits the possibility of using commercial software for thermoluminescence and optically stimulated luminescence curve deconvolution analysis. The widely used software package Microsoft Excel, with the Solver utility has been used to perform deconvolution analysis to both experimental and reference glow curves resulted from the Glow Curve Analysis Intercomparison project. The simple interface of this programme combined with the powerful Solver utility, allows the analysis of complex stimulated luminescence curves into their components and the evaluation of the associated luminescence parameters. (authors)

  10. New ages for Middle and Later Stone Age deposits at Mumba rockshelter, Tanzania: optically stimulated luminescence dating of quartz and feldspar grains.

    Science.gov (United States)

    Gliganic, Luke A; Jacobs, Zenobia; Roberts, Richard G; Domínguez-Rodrigo, Manuel; Mabulla, Audax Z P

    2012-04-01

    The archaeological deposits at Mumba rockshelter, northern Tanzania, have been excavated for more than 70 years, starting with Margit and Ludwig Köhl-Larsen in the 1930s. The assemblages of Middle Stone Age (MSA) and Later Stone Age (LSA) artefacts collected from this site constitute the type sequences for these cultural phases in East Africa. Despite its archaeological importance, however, the chronology of the site is poorly constrained, despite the application since the 1980s of several dating methods (radiocarbon, uranium-series and amino acid racemisation) to a variety of materials recovered from the deposits. Here, we review these previous chronologies for Mumba and report new ages obtained from optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL) measurements on single grains of quartz and multi-grain aliquots of potassium (K) feldspar from the MSA and LSA deposits. Measurements of single grains of quartz allowed the rejection of unrepresentative grains and the application of appropriate statistical models to obtain the most reliable age estimates, while measurements of K-feldspars allowed the chronology to be extended to older deposits. The seven quartz ages and four K-feldspar ages provide improved temporal constraints on the archaeological sequence at Mumba. The deposits associated with the latest Kisele Industry (Bed VI-A) and the earliest Mumba Industry (Bed V) are dated to 63.4 ± 5.7 and 56.9 ± 4.8 ka (thousands of years ago), respectively, thus constraining the time of transition between these two archaeological phases to ~60 ka. An age of 49.1 ± 4.3 ka has been obtained for the latest deposits associated with the Mumba Industry, which show no evidence for post-depositional mixing and contain ostrich eggshell (OES) beads and abundant microlithics. The Nasera Industry deposits (Bed III) contain large quantities of OES beads and date to 36.8 ± 3.4 ka. We compare the luminescence ages with the previous chronologies for

  11. Overview of physical dosimetry methods for triage application integrated in the new European network RENEB.

    Science.gov (United States)

    Trompier, François; Burbidge, Christopher; Bassinet, Céline; Baumann, Marion; Bortolin, Emanuela; De Angelis, Cinzia; Eakins, Jonathan; Della Monaca, Sara; Fattibene, Paola; Quattrini, Maria Cristina; Tanner, Rick; Wieser, Albrecht; Woda, Clemens

    2017-01-01

    In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Resonance (EPR) dosimetry techniques. OSL is applied to electronic components and EPR to touch-screen glass from mobile phones. To implement these new approaches, several blind tests and inter-laboratory comparisons (ILC) were organized for each assay. OSL systems have shown good performances. EPR systems also show good performance in controlled conditions, but ILC have also demonstrated that post-irradiation exposure to sunlight increases the complexity of the EPR signal analysis. Physically-based dosimetry techniques present high capacity, new possibilities for accident dosimetry, especially in the case of large-scale events. Some of the techniques applied can be considered as operational (e.g. OSL on Surface Mounting Devices [SMD]) and provide a large increase of measurement capacity for existing networks. Other techniques and devices currently undergoing validation or development in Europe could lead to considerable increases in the capacity of the RENEB accident dosimetry network.

  12. Luminescence dating of the Zeketai loess section in the Ili Basin, northwestern China: Methodological considerations

    Science.gov (United States)

    Qin, Jintang; Zhou, Liping

    2018-04-01

    Loess deposits in Xinjiang, northwestern China are ideal archives for past environmental changes in the Westerlies-dominated central Asia. Among previous luminescence dating studies of loess in Xinjiang, few have attempted to systematically investigate the methodological aspects. In this study, we report results of a multiple-procedure luminescence dating of the Zeketai loess section in the Ili Basin, central Xinjiang. Optically stimulated luminescence (OSL) and post-infrared infrared stimulated luminescence (pIRIR) signals were used for quartz and polymineral grains of different sizes. The pIRIR ages obtained with two protocols agree well with each other and constrain the loess deposition between 50 ka and 88 ka. The OSL ages of fine-grained quartz are in stratigraphic order and range from 37 ka to 61 ka, but are ∼30% younger than the pIRIR295 ages of both fine and medium grained polyminerals. Although the causes of the discrepancy between the ages derived from different luminescence dating protocols are still to be understood, we stress that the quartz OSL ages of loess in this region are likely to be underestimated, especially for samples older than 40 ka. The polymineral or potassium feldspar pIRIR signal is recommended for dating loess in the Ili Basin, at least as an internal check.

  13. Non-scanning fiber-optic near-infrared beam led to two-photon optogenetic stimulation in-vivo.

    Directory of Open Access Journals (Sweden)

    Kamal R Dhakal

    Full Text Available Stimulation of specific neurons expressing opsins in a targeted region to manipulate brain function has proved to be a powerful tool in neuroscience. However, the use of visible light for optogenetic stimulation is invasive due to low penetration depth and tissue damage owing to larger absorption and scattering. Here, we report, for the first time, in-depth non-scanning fiber-optic two-photon optogenetic stimulation (FO-TPOS of neurons in-vivo in transgenic mouse models. In order to optimize the deep-brain stimulation strategy, we characterized two-photon activation efficacy at different near-infrared laser parameters. The significantly-enhanced in-depth stimulation efficiency of FO-TPOS as compared to conventional single-photon beam was demonstrated both by experiments and Monte Carlo simulation. The non-scanning FO-TPOS technology will lead to better understanding of the in-vivo neural circuitry because this technology permits more precise and less invasive anatomical delivery of stimulation.

  14. Luminescence optically stimulated: theory and applications; Luminiscencia opticamente estimulada: teoria y aplicaciones

    Energy Technology Data Exchange (ETDEWEB)

    Rivera M, T.; Azorin N, J. [Departamento de Fisica, Universidad Autonoma Metropolitana-Iztapalapa, 09340 Mexico D.F. (Mexico)

    2002-07-01

    The thermally stimulated luminescence (Tl) has occupied an important place in the Solid state physics (FES) by the flexibility of the phenomena, mainly for its applications in the fields of Radiation Physics (FR) and Medical Physics (MF). The reason of this phenomena lies in the fact of the electrons release by the action of heat. Under that same reason, it can be used the action of another stimulant agent for releasing the trapped electrons in the metastable states (EM), this agent is the light which has the same effect that the heat, giving as result the production of light photons at using light in the visible spectra, of different wavelength that the excitation light. This phenomena is called Luminescence optically stimulated (LOE). The LOE has a great impact in the Solid State Physics (FES), dating and now in the use of the phenomena as a dosimetric method, alternate to the Tl, for its use in the ionizing and non-ionizing radiations fields. (Author)

  15. Optical coherence tomography and optical coherence domain reflectometry for deep brain stimulation probe guidance

    Science.gov (United States)

    Jeon, Sung W.; Shure, Mark A.; Baker, Kenneth B.; Chahlavi, Ali; Hatoum, Nagi; Turbay, Massud; Rollins, Andrew M.; Rezai, Ali R.; Huang, David

    2005-04-01

    Deep Brain Stimulation (DBS) is FDA-approved for the treatment of Parkinson's disease and essential tremor. Currently, placement of DBS leads is guided through a combination of anatomical targeting and intraoperative microelectrode recordings. The physiological mapping process requires several hours, and each pass of the microelectrode into the brain increases the risk of hemorrhage. Optical Coherence Domain Reflectometry (OCDR) in combination with current methodologies could reduce surgical time and increase accuracy and safety by providing data on structures some distance ahead of the probe. For this preliminary study, we scanned a rat brain in vitro using polarization-insensitive Optical Coherence Tomography (OCT). For accurate measurement of intensity and attenuation, polarization effects arising from tissue birefringence are removed by polarization diversity detection. A fresh rat brain was sectioned along the coronal plane and immersed in a 5 mm cuvette with saline solution. OCT images from a 1294 nm light source showed depth profiles up to 2 mm. Light intensity and attenuation rate distinguished various tissue structures such as hippocampus, cortex, external capsule, internal capsule, and optic tract. Attenuation coefficient is determined by linear fitting of the single scattering regime in averaged A-scans where Beer"s law is applicable. Histology showed very good correlation with OCT images. From the preliminary study using OCT, we conclude that OCDR is a promising approach for guiding DBS probe placement.

  16. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    Energy Technology Data Exchange (ETDEWEB)

    Tudela, Diego R.G.; Tatumi, Sonia H.; Yee, Marcio; Brito, Silvio L.M., E-mail: tatumi@fatecsp.br [Faculdades de Tecnologia de Sao Paulo (FATECs/CEETEPS/UNESP), Sao Paulo, SP (Brazil). Centro Estadual de Educacao Tecnologica Paula Souza; Morais, Jose L.; Morais, Daisy de; Piedade, Silvia C. [Universidade de Sao Paulo (USP), SP (Brazil). Museu de Arqueologia e Etnologia; Munita, Casimiro S.P.; Hazenfratz, Roberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-06-15

    This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at 'Luz' Monastery, located in the state of Sao Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments. (author)

  17. The first neural probe integrated with light source (blue laser diode) for optical stimulation and electrical recording.

    Science.gov (United States)

    Park, HyungDal; Shin, Hyun-Joon; Cho, Il-Joo; Yoon, Eui-sung; Suh, Jun-Kyo Francis; Im, Maesoon; Yoon, Euisik; Kim, Yong-Jun; Kim, Jinseok

    2011-01-01

    In this paper, we report a neural probe which can selectively stimulate target neurons optically through Si wet etched mirror surface and record extracellular neural signals in iridium oxide tetrodes. Consequently, the proposed approach provides to improve directional problem and achieve at least 150/m gap distance between stimulation and recording sites by wet etched mirror surface in V-groove. Also, we developed light source, blue laser diode (OSRAM Blue Laser Diode_PL 450), integration through simple jig for one-touch butt-coupling. Furthermore, optical power and impedance of iridium oxide tetrodes were measured as 200 μW on 5 mW from LD and 206.5 k Ω at 1 kHz and we demonstrated insertion test of probe in 0.5% agarose-gel successfully. We have successfully transmitted a light of 450 nm to optical fiber through the integrated LD using by butt-coupling method.

  18. Potential application of metal nanoparticles for dosimetric systems: Concepts and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Guidelli, Eder José, E-mail: ederguidelli@pg.ffclrp.usp.br; Baffa, Oswaldo, E-mail: ederguidelli@pg.ffclrp.usp.br [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Av. Bandeirantes, 3900, 14040-901, Ribeirão Preto, SP (Brazil)

    2014-11-07

    Metallic nanoparticles increase the delivered dose and consequently enhance tissue radio sensitization during radiation therapy of cancer. The Dose Enhancement Factor (DEF) corresponds to the ratio between the dose deposited on a tissue containing nanoparticles, and the dose deposited on a tissue without nanoparticles. In this sense, we have used electron spin resonance spectroscopy (ESR) to investigate how silver and gold nanoparticles affect the dose deposition in alanine dosimeters, which act as a surrogate of soft tissue. Besides optimizing radiation absorption by the dosimeter, the optical properties of these metal nanoparticles could also improve light emission from materials employed as radiation detectors. Therefore, we have also examined how the plasmonic properties of noble metal nanoparticles could enhance radiation detection using optically stimulated luminescence (OSL) dosimetry. This work will show results on how the use of gold and silver nanoparticles are beneficial for the ESR and OSL dosimetric techniques, and will describe the difficulties we have been facing, the challenges to overcome, and the perspectives.

  19. Thermoluminescence dosimetry of electronic components from personal objects

    International Nuclear Information System (INIS)

    Beerten, Koen; Woda, Clemens; Vanhavere, Filip

    2009-01-01

    Owing to the existence of ceramic materials inside common personal objects such as cellular phones and USB flash drives, these objects may be very useful in emergency (accident) dosimetry. Here we will present initial results regarding the dosimetric properties as determined by thermoluminescence (TL) from two alumina-rich electronic components from a USB flash drive. The TL method was applied in order to investigate the potential of conventional TL equipment for such purposes. For comparison, the optically stimulated luminescence (OSL) of the components was investigated as well. The studied components are ceramic resonators and alumina-based substrates from electrical resistors. The results show that various TL-related properties such as fading, optical stability and zero-dose response are different for the two investigated components. On the basis of these properties, the ceramic resonator was selected for dose recovery tests using TL and OSL. The given dose could reliably be determined using both methods, assuming that prompt measurement and/or fading correction is possible.

  20. Thermoluminescence, luminescence optically stimulated and creation of defects in alkaline halogenides contaminated with Europium

    International Nuclear Information System (INIS)

    Barboza F, M.

    1999-01-01

    The alkaline halogenides have been subject matter of investigations related with the search of sensor materials for X-ray bidimensional images or optical memories. The understanding of the damage formation processes generated by ionizing and non-ionizing radiations is important for the correct design of devices that working as detectors and dosemeters of both type of radiations. In this work we present the investigation results related with the defects produced by the ionizing radiation type X and ultraviolet light in the range of 200-360 nm in crystals of KCl: Eu 2+ and KBr:Eu 2+ . It is examined the thermoluminescence and luminescence spectra with the purpose of identifying the exciton processes, owing to the excitation of the halogenide ions in which the primary defects correspond to the F and H centers. It has been found that the 400-600 nm emission is associated with the luminescence type that in his turn can be associated with autotrapped excitons perturbed by the impurity. On the other hand, it is examined the emission spectra of the luminescence optically stimulated in crystals of KBr: Eu 2+ and KCl: Eu 2+ finding too that such materials would be used as optical memories susceptible of to store information, and through of photostimulation to read this. It was determined that the F centers participate in the luminescence optically stimulated in these crystals, as well as too in the recombination processes responsible by the thermoluminescent emission. (Author)

  1. Retrospective and emergency dosimetry in response to radiological incidents and nuclear mass-casualty events : a review.

    OpenAIRE

    Bailiff, I.K.; Sholom, S.; McKeever, S.W.S.

    2016-01-01

    This paper reviews recent research on the application of the physical dosimetry techniques of electron paramagnetic resonance (EPR) and luminescence (optically stimulated luminescence, OSL, and thermoluminescence, TL) to determine radiation dose following catastrophic, large-scale radiological events. Such data are used in dose reconstruction to obtain estimates of dose due to the exposure to external sources of radiation, primarily gamma radiation, by individual members of the public and by ...

  2. Thermally assisted OSL application for equivalent dose estimation; comparison of multiple equivalent dose values as well as saturation levels determined by luminescence and ESR techniques for a sedimentary sample collected from a fault gouge

    Energy Technology Data Exchange (ETDEWEB)

    Şahiner, Eren, E-mail: sahiner@ankara.edu.tr; Meriç, Niyazi, E-mail: meric@ankara.edu.tr; Polymeris, George S., E-mail: gspolymeris@ankara.edu.tr

    2017-02-01

    Highlights: • Multiple equivalent dose estimations were carried out. • Additive ESR and regenerative luminescence were applied. • Preliminary SAR results employing TA-OSL signal were discussed. • Saturation levels of ESR and luminescence were investigated. • IRSL{sub 175} and SAR TA-OSL stand as very promising for large doses. - Abstract: Equivalent dose estimation (D{sub e}) constitutes the most important part of either trap-charge dating techniques or dosimetry applications. In the present work, multiple, independent equivalent dose estimation approaches were adopted, using both luminescence and ESR techniques; two different minerals were studied, namely quartz as well as feldspathic polymineral samples. The work is divided into three independent parts, depending on the type of signal employed. Firstly, different D{sub e} estimation approaches were carried out on both polymineral and contaminated quartz, using single aliquot regenerative dose protocols employing conventional OSL and IRSL signals, acquired at different temperatures. Secondly, ESR equivalent dose estimations using the additive dose procedure both at room temperature and at 90 K were discussed. Lastly, for the first time in the literature, a single aliquot regenerative protocol employing a thermally assisted OSL signal originating from Very Deep Traps was applied for natural minerals. Rejection criteria such as recycling and recovery ratios are also presented. The SAR protocol, whenever applied, provided with compatible D{sub e} estimations with great accuracy, independent on either the type of mineral or the stimulation temperature. Low temperature ESR signals resulting from Al and Ti centers indicate very large D{sub e} values due to bleaching in-ability, associated with large uncertainty values. Additionally, dose saturation of different approaches was investigated. For the signal arising from Very Deep Traps in quartz saturation is extended almost by one order of magnitude. It is

  3. Luminescence of quartz and feldspar fingerprints provenance and correlates with the source area denudation in the Amazon River basin

    Science.gov (United States)

    Sawakuchi, A. O.; Jain, M.; Mineli, T. D.; Nogueira, L.; Bertassoli, D. J.; Häggi, C.; Sawakuchi, H. O.; Pupim, F. N.; Grohmann, C. H.; Chiessi, C. M.; Zabel, M.; Mulitza, S.; Mazoca, C. E. M.; Cunha, D. F.

    2018-06-01

    The Amazon region hosts the world's largest watershed spanning from high elevation Andean terrains to lowland cratonic shield areas in tropical South America. This study explores variations in optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL) signals in suspended silt and riverbed sands retrieved from major Amazon rivers. These rivers drain Pre-Cambrian to Cenozoic source rocks in areas with contrasting denudation rates. In contrast to the previous studies, we do not observe an increase in the OSL sensitivity of quartz with transport distance; for example, Tapajós and Xingu Rivers show more sensitive quartz than Solimões and Madeira Rivers, even though the latter have a significantly larger catchment area and longer sediment transport distance. Interestingly, high sensitivity quartz is observed in rivers draining relatively stable Central Brazil and Guiana shield areas (denudation rate ξ = 0.04 mmyr-1), while low sensitivity quartz occurs in less stable Andean terrains (ξ = 0.24 mmyr-1). An apparent linear correlation between quartz OSL sensitivity and denudation rate suggests that OSL sensitivity may be used as a proxy for erosion rates in the Amazon basin. Furthermore, luminescence sensitivity measured in sand or silt arises from the same mineral components (quartz and feldspar) and clearly discriminates between Andean and shield sediments, avoiding the grain size bias in provenance analysis. These results have implications for using luminescence sensitivity as a proxy for Andean and shield contributions in the stratigraphic record, providing a new tool to reconstruct past drainage configurations within the Amazon basin.

  4. Development and implementation of In-vivo dosimetry with OSL in special techniques (IMRT, TBI, TSE); Desarrollo e implementacion de dosimetria In-vivo con OSL en tecnicas especiales (IMRT, TBI, TSE)

    Energy Technology Data Exchange (ETDEWEB)

    Bourel, V., E-mail: vbourel@favaloro.edu.ar [Universidad Favaloro, Buenos Aires (Argentina)

    2015-10-15

    Full text: Special techniques of radiation treatments generally require a quality control very thorough because in general tend to be high-risk techniques of complications due to imparting high doses in a small volume or involve a very large volume of the patient are the techniques of total body irradiation either photons or electrons. In these techniques a moderate error in the given dose can mean a very significant variation in tumor control probability (Tcp) or the likelihood of complications in normal tissues has happened in known published accidents and can be deduced from the typical sigmoid curve of response vs. dose. The technique In-vivo dosimetry has proved useful a final tool to detect any possible error in the chain of procedures to which is subjected prior to radiation treatment. This chain of procedures includes initial imaging, treatment planning involving the calibration of the equipment s, location and immobilization of the patient. The In-vivo dosimetry involves a measurement of the dose delivered to the patient in the treatment conditions to detect a possible deviation between the prescribed and the delivered dose. The experience so far has been done mainly with semiconductor elements (diodes) or thermoluminescent dosimetry. The advent of the optically stimulated luminescence dosimeters (OSLD), particularly in the nano Dots form, is a very appropriate tool for its size, ease of handling, accurate and fast reading. With these dosimeters has been developed and implemented the In-vivo dosimetry in three techniques in which the accuracy of the dose delivered is extremely important. These techniques are the treatment of intensity modulated radiation therapy (IMRT) that seeks to impart a very high dose in the tumor tissues protecting organs in risk around the target and the techniques of total body irradiation with photons, whose function is to generate immune suppression in patients before being transplanted, or with electrons for the treatment of

  5. A new mathematical approximation of sunlight attenuation in rocks for surface luminescence dating

    Energy Technology Data Exchange (ETDEWEB)

    Laskaris, Nikolaos, E-mail: nick.laskaris@gmail.com [University of the Aegean, Department of Mediterranean Studies, Laboratory of Archaeometry, 1 Demokratias Avenue, Rhodes 85100 (Greece); Liritzis, Ioannis, E-mail: liritzis@rhodes.aegean.gr [University of the Aegean, Department of Mediterranean Studies, Laboratory of Archaeometry, 1 Demokratias Avenue, Rhodes 85100 (Greece)

    2011-09-15

    The attenuation of sunlight through different rock surfaces and the thermoluminescence (TL) or Optical stimulated luminescence (OSL) residuals clock resetting derived from sunlight induced eviction of electrons from electron traps, is a prerequisite criterion for potential dating. The modeling of change of residual luminescence as a function of two variables, the solar radiation path length (or depth) and exposure time offers further insight into the dating concept. The double exponential function modeling based on the Lambert-Beer law, valid under certain assumptions, constructed by a quasi-manual equation fails to offer a general and statistically sound expression of the best fit for most rock types. A cumulative log-normal distribution fitting provides a most satisfactory mathematical approximation for marbles, marble schists and granites, where absorption coefficient and residual luminescence parameters are defined per each type of rock or marble quarry. The new model is applied on available data and age determination tests. - Highlights: > Study of aattenuation of sunlight through different rock surfaces. > Study of the thermoluminescence (TL) or Optical stimulated luminescence (OSL) residuals as a function of depth. > A Cumulative Log-Normal Distribution fitting provides the most satisfactory modeling for marbles, marble schists and granites. > The new model (Cummulative Log-Norm Fitting) is applied on available data and age determination tests.

  6. A new mathematical approximation of sunlight attenuation in rocks for surface luminescence dating

    International Nuclear Information System (INIS)

    Laskaris, Nikolaos; Liritzis, Ioannis

    2011-01-01

    The attenuation of sunlight through different rock surfaces and the thermoluminescence (TL) or Optical stimulated luminescence (OSL) residuals clock resetting derived from sunlight induced eviction of electrons from electron traps, is a prerequisite criterion for potential dating. The modeling of change of residual luminescence as a function of two variables, the solar radiation path length (or depth) and exposure time offers further insight into the dating concept. The double exponential function modeling based on the Lambert-Beer law, valid under certain assumptions, constructed by a quasi-manual equation fails to offer a general and statistically sound expression of the best fit for most rock types. A cumulative log-normal distribution fitting provides a most satisfactory mathematical approximation for marbles, marble schists and granites, where absorption coefficient and residual luminescence parameters are defined per each type of rock or marble quarry. The new model is applied on available data and age determination tests. - Highlights: → Study of aattenuation of sunlight through different rock surfaces. → Study of the thermoluminescence (TL) or Optical stimulated luminescence (OSL) residuals as a function of depth. → A Cumulative Log-Normal Distribution fitting provides the most satisfactory modeling for marbles, marble schists and granites. → The new model (Cummulative Log-Norm Fitting) is applied on available data and age determination tests.

  7. Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI

    International Nuclear Information System (INIS)

    Almeida, Shirlane Barbosa de

    2017-01-01

    In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin. (author)

  8. Measuring modulated luminescence using non-modulated stimulation: Ramping the sample period

    DEFF Research Database (Denmark)

    Poolton, N.R.J.; Bøtter-Jensen, L.; Andersen, C.E.

    2003-01-01

    . Directly analogous results to LM-OSL can, however, be achieved with non-modulated excitation sources, by ramping the sample period (RSP) of luminescence detection. RSP-OSL has the distinct advantage over LM-OSL in that, since the excitation remains at full power, data accumulation times (that can...... be considerable) can be reduced by typically 50%. RSP methods are universally applicable and can be employed, for example, where the excitation source is constant heat, rather than light: here, iso-thermal decay of phosphorescence becomes recorded as a sequence of peaks, corresponding to de-trapping of charge...

  9. Dosimetric characterization of BeO samples in alpha, beta and X radiation beams using luminescent techniques

    International Nuclear Information System (INIS)

    Groppo, Daniela Piai

    2013-01-01

    In the medical field, the ionizing radiation is used both for therapeutic and diagnostic purposes, in a wide range of radiation doses. In order to ensure that the objective is achieved in practice, detailed studies of detectors and devices in different types of radiations beams are necessary. In this work a dosimetric characterization of BeO samples was performed using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL) by a comparison of their response for alpha, beta and X radiations and the establishment of an appropriated system for use in monitoring of these radiations beams. The main results are: the high sensitivity to beta radiation for both techniques, good reproducibility of TL and OSL response (coefficients of variation lower than 5%), maximum energy dependence of the X radiation of 28% for the TL technique, and only 7% for the OSL technique, within the studied energy range. The dosimetric characteristics obtained in this work show the possibility of applying BeO samples to dosimetry of alpha, beta and X radiations, considering the studied dose ranges, using the TL and OSL techniques. From the results obtained, the samples of BeO showed their potential use for beam dosimetry in diagnostic radiology and radiotherapy. (author)

  10. Micro/nano phosphors for gamma, electron, fast and thermal neutron dosimetry: an overview

    International Nuclear Information System (INIS)

    Dhole, Sanjay D.

    2016-01-01

    In this talk an overview of the micro/nano phosphors, nuclear track in glass and Fricke dosimeter will be covered. Eu and Cu doped K_2Ca_2(SO_4)_3 by chemical co-precipitation, CaSO_4:Dy (micro by acid re-crystallization method and Al_2O_3:C by Thermal Plasma reactor method were synthesized and their photoluminescence (PL), Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) properties were characterized

  11. A gamma/neutron-discriminating, Cooled, Optically Stimulated Luminescence (COSL) dosemeter

    International Nuclear Information System (INIS)

    Eschbach, P.A.; Miller, S.D.

    1992-07-01

    The Cooled Optically Stimulated Luminescence (COSL) of CaF 2 :Mn (grain sizes from 0.1 to 100 microns) powder embedded in a hydrogenous matrix is reported as a function of fast-neutron dose. When all the CaF 2 :Mn grains are interrogated at once, the COSL plastic dosemeters have a minimum detectable limit of 1 cSv fast neutrons; the gamma component from the bare 252 cf exposure was determined with a separate dosemeter. We report here on a proton-recoil-based dosemeter that generates pulse height spectra, much like the scintillator of Hornyak, (2) to provide information on both the neutron and gamma dose

  12. Sensory stimulation for lowering intraocular pressure, improving blood flow to the optic nerve and neuroprotection in primary open-angle glaucoma.

    Science.gov (United States)

    Rom, Edith

    2013-12-01

    Primary open-angle glaucoma is a group of optic neuropathies that can lead to irreversible blindness. Sensory stimulation in the form of acupuncture or ear acupressure may contribute to protecting patients from blindness when used as a complementary method to orthodox treatment in the form of drops, laser or surgery. The objective of this article is to provide a narrative overview of the available literature up to July 2012. It summarises reported evidence on the potential beneficial effects of sensory stimulation for glaucoma. Sensory stimulation appears to significantly enhance the pressure-lowering effect of orthodox treatments. Studies suggest that it may also improve blood flow to the eye and optic nerve head. Furthermore, it may play a role in neuroprotection through regulating nerve growth factor and brain-derived neurotrophic factor and their receptors, thereby encouraging the survival pathway in contrast to the pathway to apoptosis. Blood flow and neuroprotection are areas that are not directly influenced by orthodox treatment modalities. Numerous different treatment protocols were used to investigate the effect of sensory stimulation on intraocular pressure, blood flow or neuroprotection of the retina and optic nerve in the animal model and human pilot studies. Objective outcomes were reported to have been evaluated with Goldmann tonometry, Doppler ultrasound techniques and electrophysiology (pattern electroretinography, visually evoked potentials), and supported with histological studies in the animal model. Taken together, reported evidence from these studies strongly suggests that sensory stimulation is worthy of further research.

  13. Sedimentology, hydrogeology and hydrogeochemistry of Machile Basin, Zambia

    DEFF Research Database (Denmark)

    Banda, Kawawa Eddy

    . 500 ka). Methods used in the field and laboratory included: deep borehole drilling, geophysical borehole logging, groundwater table measurements, sediment dating (with optically stimulated luminescence - OSL), mineralogical analysis (XRD and SEM), groundwater tracers (18O, 2H, 3H/3He, 14C......), hydrochemistry (including pore-water), cation exchange capacity and sediment dilution experiments. Unconsolidated sediment samples at intermittent depths up to 50 m below ground level (bgl) were retrieved from a 100 m bgl research borehole. Sediment XRD analysis shows that the sediment has predominantly silicate...... minerals (quartz and feldspars) with whitish nodule like structures detected to be bassanite (dehydrated gypsum), whereas carbonates (calcite and dolomite) were below detection by XRD; a simple acid test, however, validated the presence of carbonates. OSL dating showed that the sediments are old (> 300 ka...

  14. Long-term optical stimulation of channelrhodopsin-expressing neurons to study network plasticity

    Science.gov (United States)

    Lignani, Gabriele; Ferrea, Enrico; Difato, Francesco; Amarù, Jessica; Ferroni, Eleonora; Lugarà, Eleonora; Espinoza, Stefano; Gainetdinov, Raul R.; Baldelli, Pietro; Benfenati, Fabio

    2013-01-01

    Neuronal plasticity produces changes in excitability, synaptic transmission, and network architecture in response to external stimuli. Network adaptation to environmental conditions takes place in time scales ranging from few seconds to days, and modulates the entire network dynamics. To study the network response to defined long-term experimental protocols, we setup a system that combines optical and electrophysiological tools embedded in a cell incubator. Primary hippocampal neurons transduced with lentiviruses expressing channelrhodopsin-2/H134R were subjected to various photostimulation protocols in a time window in the order of days. To monitor the effects of light-induced gating of network activity, stimulated transduced neurons were simultaneously recorded using multi-electrode arrays (MEAs). The developed experimental model allows discerning short-term, long-lasting, and adaptive plasticity responses of the same neuronal network to distinct stimulation frequencies applied over different temporal windows. PMID:23970852

  15. Long-term optical stimulation of channelrhodopsin-expressing neurons to study network plasticity.

    Science.gov (United States)

    Lignani, Gabriele; Ferrea, Enrico; Difato, Francesco; Amarù, Jessica; Ferroni, Eleonora; Lugarà, Eleonora; Espinoza, Stefano; Gainetdinov, Raul R; Baldelli, Pietro; Benfenati, Fabio

    2013-01-01

    Neuronal plasticity produces changes in excitability, synaptic transmission, and network architecture in response to external stimuli. Network adaptation to environmental conditions takes place in time scales ranging from few seconds to days, and modulates the entire network dynamics. To study the network response to defined long-term experimental protocols, we setup a system that combines optical and electrophysiological tools embedded in a cell incubator. Primary hippocampal neurons transduced with lentiviruses expressing channelrhodopsin-2/H134R were subjected to various photostimulation protocols in a time window in the order of days. To monitor the effects of light-induced gating of network activity, stimulated transduced neurons were simultaneously recorded using multi-electrode arrays (MEAs). The developed experimental model allows discerning short-term, long-lasting, and adaptive plasticity responses of the same neuronal network to distinct stimulation frequencies applied over different temporal windows.

  16. Study of sensitivity change of OSL signals from quartz and feldspars as a function of preheat temperature

    DEFF Research Database (Denmark)

    Jungner, H.; Bøtter-Jensen, L.

    1994-01-01

    and as a result, the equivalent dose (ED) would be underestimated. A study of sensitivity changes in feldspars and quartz was carried out with emphasis on the effect of preheat and annealing on the OSL signal. Measurement results obtained are presented, and possible elimination of errors in dating caused...

  17. Electrical and optical deep level spectroscopy on Os doped p-InP

    International Nuclear Information System (INIS)

    Parveen, S.; Zafar, N.; Khan, A.; Qureshi, U.S.; Iqbal, M.Z.

    1997-01-01

    Transition metal (TM) impurities are introduced for obtaining semi insulating (III-V) compound semiconductors used as base material for electronic and optoelectronic devices. TM doping introduces near mid gap levels which are used to compensate shallow level donors and acceptors in (III-V) compound semiconductors. The study of electrical properties of heavier transition metals in InP has been turned to an active field of research owing to their potential to produce thermally stable semi insulating substrate materials. Osmium has been tried for this purpose in our work. InP: Os samples have been grown by low pressure metalorganic chemical vapour deposition (LP-MOCVD). Optical and electrical Deep Level Transient Spectroscopy Techniques have been used to characterise osmium related deep level defects in the p-type samples. Three majority carrier (Hole) emitting levels OsA, OsB, OsC and one minority carrier (electron) emitting level Osl are observed in the DLTS and ODLTS measurements on p-type InP:Os. ON optical injection, only Osl appears and all other majority carrier emitting levels disappear dramatically. Special emphasis is given to the detailed comparison by ODLTS and EDLTS, which yields important information on the relative capture cross-sections of Osmium induced levels in p-InP. (author)

  18. AG, TL, and IRSL dosimetric properties in X-ray irradiated HPHT diamond crystals

    Energy Technology Data Exchange (ETDEWEB)

    Gil-Tolano, M.I. [Programa de Posgrado, Departamento de Investigacion en Fisica, Universidad de Sonora, A. P. 5-088, Hermosillo, Sonora, 83190, Mexico (Mexico); Melendrez, R.; Lancheros-Olmos, J.C.; Soto-Puebla, D.; Chernov, V.; Pedroza-Montero, M.; Barboza-Flores, M. [Departamento de Investigacion en Fisica, Universidad de Sonora, A. P. 5-088, Hermosillo, Sonora, 83190, Mexico (Mexico); Castaneda, B. [Departamento de Fisica, Universidad de Sonora, Blvd. Luis Encinas y Rosales S/N, Hermosillo, Sonora, 83000, Mexico (Mexico)

    2014-10-15

    HPHT diamonds have been studied for several years for their potential in different applications. In previous studies it has been found that the thermoluminescence (TL) glow curves of ''as-grown'' HPHT diamonds are non-reproducible. In this work, we study the afterglow (AG), thermoluminescent (TL), and optically stimulated luminescence (OSL) response of commercial samples of synthetic HPHT type-Ib diamond crystals exposed to X-ray irradiation (0.75 mA, 35 kV) at a dose rate of 0.624 Gy/s, after a high gamma ({sup 60}Co) dose irradiation of 500 kGy followed by a thermal treatment at 1073 K for 1 h in nitrogen atmosphere. Deconvolution of the TL glow curves shows four peaks, located around 379, 509, 561, and 609 K. The crystals exhibit evident AG recorded for 300 s immediately after X-ray irradiation, due to the thermal emptying of the traps responsible for the low-temperature TL peaks (below 400 K). The stimulation of irradiated crystals with 870-nm light, creates pronounced OSL and destroys all TL peaks with the exception of the high-temperature peak at 609 K. The dose responses of the integrated AG, TL, and OSL are linear in the range of 0.6-5 Gy and saturated at higher doses. The reproducibility of AG, TL, and OSL measurements is about 5%. The fading in the first hour of storage in dark conditions at RT of TL signal of HPHT diamond is mainly associated to the emptying of the traps responsible for the 379-K TL peaks. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Recovery of α-Al{sub 2}O{sub 3} from ionizing radiation dosimetric sensors

    Energy Technology Data Exchange (ETDEWEB)

    Sanches, Edgar Aparecido, E-mail: sanches.ufam@gmail.com [Universidade Federal do Amazonas (UFAM), Manaus, AM (Brazil). Dept. de Fisica; Costalonga, Ademir Geraldo Cavallari; Mascarenhas, Yvonne Primerano [Universidade de Sao Paulo (IFSC/USP), Sao Carlos, SP (Brazil). Institute de Fisica; Nascimento, Luana de Freitas [Belgium Nuclear Research Centre, SCK-CEN, Mol (Belgium); Mascarenhas, Yvone Maria [SAPRA S/A Servico de Assessoria e Protecao Radiologica, Sao Carlos, SP, (Brazil)

    2015-01-15

    Corundum, sapphire or α-Al{sub 2}O{sub 3} is an important technological material in many optical and electronic applications such as solid-state lasers, optical windows and, more recently, as a radiation detector. Landauer (Glenwood, IL, USA) accumulated large number of archived and stored Luxel™ dosemeters composed of Al{sub 2}O{sub 3}:C, which were subjected to a recovery process. Due to the importance of this advanced crystalline material in OSL dosimetry, a recovery process was developed based on the dosemeters calcination and Al{sub 2}O{sub 3}:C has been reused in manufacturing of new dosemeters. This paper does not aim to optimize the recovery process, but provides an opportunity to study the involved process parameters and to recover this valuable crystalline material from used dosemeters. To the best of our knowledge no other recovery process involving this dosimetric material was described in scientific literature. Fourier Transform Infrared Spectrometry (FTIR), Thermogravimetry/Differential Thermoanalysis (TG/DTA), Differential Scanning Calorimetry (DSC), X-ray Diffraction (XRD), Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), Optically Stimulated Luminescence (OSL) and Rietveld Refinement were used to characterize the recovered material and to check for the stability of its structural and dosimetric properties. (author)

  20. Reliability of equivalent-dose determination and age-models in the OSL dating of historical and modern palaeoflood sediments

    DEFF Research Database (Denmark)

    Medialdea, Alicia; Thomsen, Kristina Jørkov; Murray, Andrew Sean

    2014-01-01

    model to small aliquot (similar to 30 grains) dose distributions. From our study we conclude that these and similar young slack-water flood deposits can be accurately dated using quartz OSL, opening up the possibility of establishing time series of flood discharge in catchments for which no instrumental...

  1. Developments in radiation, stimulation and observation facilities in luminescence measurements

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Andersen, C.E.; Duller, G.A.T.

    2003-01-01

    of magnitude up to more than 2 Gy/s. A separate bleaching facility has also been added to the reader, new powerful infrared (IR) light-emitting diodes have replaced the IR laser diode in the general OSL unit, and an IR laser has been included in the single-grain OSL attachment. This paper describes these new...

  2. Timing of lake-level changes for a deep last-glacial Lake Missoula: optical dating of the Garden Gulch area, Montana, USA

    Science.gov (United States)

    Smith, Larry N.; Sohbati, Reza; Buylaert, Jan-Pieter; Lian, Olav B.; Murray, Andrew; Jain, Mayank

    2018-03-01

    Glaciolacustrine sediments in the Clark Fork River valley at Garden Gulch, near Drummond, Montana, USA record highstand positions of the ice-dammed glacial Lake Missoula and repeated subaerial exposure. During these highstands the lake was at greater than 65% of its recognized maximum capacity. The initial lake transgression deposited a basal sand unit. Subsequent cycles of lake-level fluctuations are recorded by sequences of laminated and cross laminated silt, sand, and clay deformed by periglacial processes during intervening periods of lower lake levels. Optically stimulated luminescence (OSL) dating of quartz sand grains, using single-aliquot regenerative-dose procedures, was carried out on 17 samples. Comparison of infrared stimulated luminescence (IRSL) from K-rich feldspar to OSL from quartz for all the samples suggests that they were well bleached prior to deposition and burial. Ages for the basal sand and overlying glaciolacustrine exposure surfaces are indistinguishable within one standard deviation, and give a weighted mean age of 20.9 ± 1.3 ka (n = 11). Based on sedimentological and stratigraphic analysis we infer that the initial transgression, and at least six cycles of lake-level fluctuation, occurred over time scales of decades to ∼2 ka. Bioturbated sandy slopewash dated at 10.6 ± 0.9 ka and 11.9 ± 1.2 ka unconformably overlies the upper glaciolacustrine deposits. The uppermost sediments, above the glaciolacustrine section, are younger than the Glacier Peak tephra (13.7-13.4 cal ka B.P.), which was deposited across parts of the drained lake basin, but has not been found at Garden Gulch. Our study indicates that glacial Lake Missoula reached >65 percent of maximum capacity by about 20.9 ± 1.3 ka and either partially or completely drained twelve times from this position. Rapid lowering from the lake's highstand position due to ice-dam failure likely led to scour in the downstream portions of the glacial Lake Missoula basin and megafloods in the

  3. Laser stimulating ST36 with optical fiber induce blood component changes in mice: a Raman spectroscopy study.

    Science.gov (United States)

    Zhang, Heng; Chen, Zhenyi; Wu, Jiping; Chen, Na; Xu, Wenjie; Li, Taihao; Liu, Shupeng

    2018-02-15

    ST36 is a commonly-used acupoint in traditional Chinese medicine (TCM) for treatment of inflammations, pains and gastrointestinal disturbs. For decades, the low power laser acupuncture has been widely applied as an alternative therapy to traditional metal needle acupuncture and achieved relatively fine therapeutic effect for ST36-related symptoms with reduction of uncomfortableness and infection risks. However its disadvantages of low penetrativity and lack of manipulation skills limit its potential performance. An optical fiber laser acupuncture introduced by the previous study combines traditional needling acupuncture and the laser stimulation together, making a stronger therapeutic effect and showing a potential value in clinical application. To evaluate its acupunctural effect on blood, mice are taken as experimental model and Raman spectroscopic technique is used to analysis the changes of blood components after stimulating on ST36. The results show that both the traditional needling acupuncture and optical fiber acupuncture could lead to some spectral changes of blood in mice. This study explores the optical fiber acupuncture's effect on blood in mice using Raman spectroscopy technique for mechanism of acupuncture therapy. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

    DEFF Research Database (Denmark)

    Andersen, Claus Erik

    2011-01-01

    . Some crystalline phosphors, such as carbon-doped aluminium oxide (Al2O3:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal......Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub......-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic...

  5. All-optical recording and stimulation of retinal neurons in vivo in retinal degeneration mice

    Science.gov (United States)

    Strazzeri, Jennifer M.; Williams, David R.; Merigan, William H.

    2018-01-01

    Here we demonstrate the application of a method that could accelerate the development of novel therapies by allowing direct and repeatable visualization of cellular function in the living eye, to study loss of vision in animal models of retinal disease, as well as evaluate the time course of retinal function following therapeutic intervention. We use high-resolution adaptive optics scanning light ophthalmoscopy to image fluorescence from the calcium sensor GCaMP6s. In mice with photoreceptor degeneration (rd10), we measured restored visual responses in ganglion cell layer neurons expressing the red-shifted channelrhodopsin ChrimsonR over a six-week period following significant loss of visual responses. Combining a fluorescent calcium sensor, a channelrhodopsin, and adaptive optics enables all-optical stimulation and recording of retinal neurons in the living eye. Because the retina is an accessible portal to the central nervous system, our method also provides a novel non-invasive method of dissecting neuronal processing in the brain. PMID:29596518

  6. Luminescence characteristics of quartz from Hsuehshan Range (Central Taiwan) and implications for thermochronometry

    International Nuclear Information System (INIS)

    Wu, Tzu-Shuan; Jain, Mayank; Guralnik, Benny; Murray, Andrew S.; Chen, Yue-Gau

    2015-01-01

    The mountain building processes in Taiwan are currently among the most rapid in the world. However, the spatial and temporal dynamics of this orogen are still poorly resolved within the <0.5 Ma timescale, reflecting methodological gaps in addressing young and rapid bedrock cooling by erosion. Optically Stimulated Luminescence (OSL) from quartz is an emerging thermochronometer that could potentially provide valuable low-temperature markers on a ∼0.1 Ma timescale. Here we study four meta-sandstone samples from the Hsuehshan Range in central Taiwan. We characterize the OSL from these samples in terms of feldspar contamination, saturation dose, signal components, and thermal stability. We conclude that the OSL is dominated by the fast component, and is therefore amenable to dose measurement using the SAR protocol. Based on the luminescence characteristics and ambient dose rate, we suggest that these samples may be valuable for evaluating recent cooling rates exceeding 360 ± 100 °C/Ma, in places where the alternative thermal scenarios (instantaneous cooling or prolonged isothermal storage) may be ruled out by external geological constraints. - Highlights: • Bedrock quartz with well-behaved luminescence characteristics are found in Taiwan. • Kinetic parameters for samples in this study are confirmed as typical quartz. • Quartz OSL-thermochronometer may work for cooling rate exceeding 360 ± 100 °C/Ma.

  7. Construction ages of the Upton Stone Chamber: Preliminary findings and suggestions for future luminescence research

    Science.gov (United States)

    Mahan, Shannon; Martin, Frederick; Taylor, Cathy

    2015-01-01

    The Upton Chamber in Massachusetts, an earth-covered stone structure 3.4 meters (m) in diameter, with a corbelled stone dome, and a 4.3 m long entrance passageway, is studied with the aim of determining whether optically stimulated luminescence (OSL) dating methods can be used to establish the approximate construction date of the entranceway. Three samples, taken from soil behind the lowest stones in the wall of the entrance passageway, returned OSL ages between 385 and 660 years ago (or from 1625 A.D. to 1350 A.D.; using the year 2011 as the 0 year). One sample, taken below the bottom of the artifact layers in an archeological test pit in front of the chamber entrance, returned OSL ages between 650 and 880 years ago. A modern sample collected from a nearby fluvial channel returned an age between 55 and 175 years. The Upton Chamber OSL sampling results are challenging to interpret because there are mixtures in the samples of both younger and older grains that likely result from human modification, root or soil processes, animal bioturbation (i.e. ants and worms), and/or partial bleaching. The ages were determined using the lowest component of the finite mixture model as applied to a distribution of quartz grains. Further research may enable us to determine whether older components are of anthropomorphic or geological origin.

  8. A survey of the signal stability and radiation dose response of sulfates in the context of adapting optical dating for Mars

    International Nuclear Information System (INIS)

    O'Connor, V.A.; Lepper, K.; Morken, T.O.; Thorstad, D.J.; Podoll, A.; Giles, M.J.

    2011-01-01

    The Martian landscape is currently dominated by eolian processes, and eolian dunes are a direct geomorphic expression of the dynamic interaction between the atmosphere and the lithosphere of planets. The timing, frequency, and spatial extent of dune mobility directly reflects changing climatic conditions, therefore, sedimentary depositional ages are important for understanding the paleoclimatic and geomorphologic history of features and processes present on the surface of the Earth or Mars. Optical dating is an established terrestrial dosimetric dating technique that is being developed for this task on Mars. Gypsum and anhydrite are two of the most stable and abundant sulfate species found on the Earth, and they have been discovered in Martian sediments along with various magnesium sulfates and jarosite. In this study, the optical dating properties of various Ca-, Mg-, and Fe-bearing sulfates were documented to help evaluate the influence they may have on in-situ optical dating in eolian environments on Mars. Single-aliquot regenerative-dose (SAR) experimental procedures have been adapted to characterize the radiation dose response and signal stability of the Martian sulfate analogs. Jarosite was dosimetrically inert in our experiments. The radiation dose response of the Ca- and Mg-sulfates was monotonically increasing in all cases with characteristic doses ranging from ∼100 to ∼1000 Gy. Short-term signal fading also varied considerably in the Ca- and Mg-sulfates ranging from ∼0% to ∼40% per decade for these materials. These results suggest that the OSL properties of Ca- and Mg-sulfates will need to be considered when developing protocols for in-situ optical dating on Mars, but more enticingly, our results foreshadow the potential for gypsum to be developed as a geochronometer for Mars or the Earth. - Highlights: → The radiation dose response and OSL signal stability of Ca- and Mg-sulfates was highly variable. → OSL properties of Ca- and Mg

  9. Soft X-ray imaging by optically stimulated luminescence from color centers in lithium fluoride

    Energy Technology Data Exchange (ETDEWEB)

    Bonfigli, F. [ENEA, C.R. Frascati, Via E. Fermi, 45, 00044 Frascati (Rome) (Italy)], E-mail: bonfigli@frascati.enea.it; Almaviva, S.; Baldacchini, G.; Bollanti, S.; Flora, F.; Lai, A.; Montereali, R.M. [ENEA, C.R. Frascati, Via E. Fermi, 45, 00044 Frascati (Rome) (Italy); Nichelatti, E. [ENEA, C.R. Casaccia, Via Anguillarese 301, 00060 S.Maria di Galeria (Rome) (Italy); Tomassetti, G.; Ritucci, A.; Reale, L. [Universita de L' Aquila e INFN, Dip. di Fisica, Coppito, L' Aquila (Italy); Faenov, A. Ya.; Pikuz, T.A. [MISDC of VNIIFTRI Mendeleevo, Moscow region, 141570 (Russian Federation); Larciprete, R. [ISC-CNR, Sezione Montelibretti, Via Salaria, Km. 29.3, 00016 Monterotondo Scalo (Rome) (Italy); Gregoratti, L.; Kiskinova, M. [Sincrotrone Trieste, S. S. 14, Km. 163.5, 34012 Basovizza (TS) (Italy)

    2007-07-15

    An innovative X-ray imaging detector based on Optically Stimulated Luminescence from color centers in lithium fluoride is presented. Regular photoluminescent patterns produced on LiF samples by different intense X-ray sources, like synchrotrons, laser plasma sources and a capillary discharge laser have been investigated by a Confocal Laser Scanning Microscope. The use of a LiF-based imaging plate for X-ray microscopy is also discussed showing microradiographies of small animals.

  10. Do you know DIS? a novel passive individual dosimeterd. Direct Ion Storage dosimeter DIS-1 officially approved in Switzerland

    International Nuclear Information System (INIS)

    Fiechtner, A.; Wernli, C.

    2001-01-01

    For individual monitoring film and TLD are the most often used types of dosimeters. On a smaller scale phosphate glasses and detectors based on optically stimulated luminescence (OSL) are also in use. As a new addition to the list of available personnel dosimeters the direct ion storage (DIS) system became legally approved for the first time in Switzerland. At the Paul Scherrer Institute (PSI) the RADOS dosimetry system DIS-1 is in official use since beginning of 2001. (orig.) [de

  11. It's about time? Testing the Dawson ceramic seriation using luminescence dating, Southern Nasca Region, Peru

    OpenAIRE

    Vaughn, KJ; Eerkens, JW; Lipo, C; Sakai, S; Schreiber, K

    2014-01-01

    Copyright © 2014 by the Society for American Archaeology. The Dawson seriation of Nasca ceramics has long been assumed to be an accurate marker of temporal changes in the pre-hispanic south coast of Peru. We test this assumption by directly dating a sample of sherds using Optically Stimulated Luminescence (OSL). Our results suggest that while some phases of the seriation are valid chronological markers, others appear to be the result of factors other than time. We discuss the implications of ...

  12. Optically stimulated luminescence techniques in retrospective dosimetry using single grains of quartz extracted from unheated materials

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov

    dosimetry). Special attention has been paid to quartz extracted from unheated building materials such as concrete and mortar. The single-aliquot regeneration-dose (SAR) protocol has been used to determine absorbeddoses in small aliquots as well as single grains of quartz. It is shown that OSL measurements...... that the observed variability in the data is consistent with the sum (in quadrature) of a component,which depends on the number of photons detected from each grain, and a fixed component independent of light level. Dose depth profiles through laboratory irradiated concrete bricks have successfully been measured...

  13. New technology development for radiation dose measurement and evaluation based on the operational quantity

    International Nuclear Information System (INIS)

    Kim, Jang Lyul; Kim, B. H.; Lee, J. I.; Lim, K. S.; Song, M. Y.; Joo, G. S.; Kim, S. I.; Chang, I. S.

    2012-04-01

    · Development of optically stimulated luminescence (OSL) technique for multi-purpose radiation dosimetry - Development of a semi-automatic type OSL measurement system · Number of sample holders: 10 ea · Development of a built-in type reference radiation irradiation system using 50 kV-1 mA X-rays of the maximum dose rate of 230 mGy/s - Development of an automatic diameter control system and crystal growth system for making a new OSL material: LiMgF 3 : X, LiAlO 2 : C - Development of a procedure of retrospective accident dosimetry · Establishment of Practical Technology for Internal Dose Assessment - Development of the technology to the internal dose assessment for an injection of radionuclides and intercomparison on the evaluation results of the committed effective dose between the estimators of Korea · Construction of workplace monitoring technique by quantification of neutron fields - Preparation of the neutron spectra DB of various neutron fields and production of those dosimetric data: 29 kinds of neutron fields using a thermal neutron irradiator, a proton accelerator and a neutron generator - Neutron monitoring procedure at workplace using neutron fluence spectra

  14. Comparative study of different Al_2O_3:C dosimeters using OSL technique for dosimetry on Volumetric Modulated Arc Radiotherapy Treatment (VMAT)

    International Nuclear Information System (INIS)

    Villani, Daniel; Campos, LetIcia L.; Mancini, Anselmo; Haddad, Cecilia M.K.

    2016-01-01

    In modern radiotherapy, the VMAT technique has become a successful treatment alternative. Due to its complexity, a quality assurance program must be established by evaluating, among other items, the dosimetric factors. This paper aims to compare the performance between the OSL aluminum oxide (Al_2O_3:C) nanoDot™ dosimeters (Inlight™ system) manufactured by Landauer Inc. and TLD-500 Al_2O_3:C dosimeters manufactured by Rexon™ for VMAT dosimetry using an anthropomorphic phantom. The results showed that both type of Al_2O_3:C dosimeters presented good repeatability and agreement between the doses measured and calculated by planning system. However, the need of sophisticated readers to OSL analysis of the TLD-500, turns it less practical for routine usage, comparing to Inlight™ system. (author)

  15. Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI; Validação e avaliação dosimétrica empregando as técnicas de TL e OSL de materiais termoluminescentes para aplicação na dosimetria de feixes clínicos de elétrons utilizados na irradiação total da pele

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Shirlane Barbosa de

    2017-07-01

    In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin. (author)

  16. Electrochemical synthesis of mesoporous gold films toward mesospace-stimulated optical properties

    Science.gov (United States)

    Li, Cuiling; Dag, Ömer; Dao, Thang Duy; Nagao, Tadaaki; Sakamoto, Yasuhiro; Kimura, Tatsuo; Terasaki, Osamu; Yamauchi, Yusuke

    2015-03-01

    Mesoporous gold (Au) films with tunable pores are expected to provide fascinating optical properties stimulated by the mesospaces, but they have not been realized yet because of the difficulty of controlling the Au crystal growth. Here, we report a reliable soft-templating method to fabricate mesoporous Au films using stable micelles of diblock copolymers, with electrochemical deposition advantageous for precise control of Au crystal growth. Strong field enhancement takes place around the center of the uniform mesopores as well as on the walls between the pores, leading to the enhanced light scattering as well as surface-enhanced Raman scattering (SERS), which is understandable, for example, from Babinet principles applied for the reverse system of nanoparticle ensembles.

  17. Comparative study of different Al{sub 2}O{sub 3}:C dosimeters using OSL technique for dosimetry on Volumetric Modulated Arc Radiotherapy Treatment (VMAT); Estudo comparativo de diferentes dosimetros de Al{sub 2}O{sub 3}:C pela tecnica OSL na dosimetria de tratamentos Radioterapicos por Arco Modulado Volumetrico (VMAT)

    Energy Technology Data Exchange (ETDEWEB)

    Villani, Daniel; Campos, LetIcia L., E-mail: dvillani@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Mancini, Anselmo; Haddad, Cecilia M.K. [Hospital Sirio-Libanes, Sao Paulo, SP (Brazil). Centro de Radioterapia

    2016-07-01

    In modern radiotherapy, the VMAT technique has become a successful treatment alternative. Due to its complexity, a quality assurance program must be established by evaluating, among other items, the dosimetric factors. This paper aims to compare the performance between the OSL aluminum oxide (Al{sub 2}O{sub 3}:C) nanoDot™ dosimeters (Inlight™ system) manufactured by Landauer Inc. and TLD-500 Al{sub 2}O{sub 3}:C dosimeters manufactured by Rexon™ for VMAT dosimetry using an anthropomorphic phantom. The results showed that both type of Al{sub 2}O{sub 3}:C dosimeters presented good repeatability and agreement between the doses measured and calculated by planning system. However, the need of sophisticated readers to OSL analysis of the TLD-500, turns it less practical for routine usage, comparing to Inlight™ system. (author)

  18. Quaternary geologic map of the north-central part of the Salinas River Valley and Arroyo Seco, Monterey County, California

    Science.gov (United States)

    Taylor, Emily M.; Sweetkind, Donald S.

    2014-01-01

    Arroyo Seco, a perennial drainage in the central Coast Range of California, records a sequence of strath terraces. These terraces preserve an erosional and depositional history, controlled by both climate change and regional tectonics. These deposits have been mapped and correlated on the basis of field investigations, digital terrain analysis, stream gradient profiles, evaluation of published regional soil maps, and satellite imagery. Seven of the strath terraces and associated alluvial fans have been dated by optically stimulated luminescence (OSL) or infrared stimulated luminescence (IRSL). The OSL and IRSL dates on seven of the strath terraces and associated alluvial fans in Arroyo Seco are approximately >120 ka, >65 ka, 51–46 ka, 36–35 ka, 9 ka, and 2–1 ka. These dates generally fall within the range of ages reported from many well-dated marine terraces on the California coast that are formed during sea-level high stands. Tectonic movements, consistently upward, result in a constantly and slowly emerging coastline, however, the regional effects of climate change and resulting eustatic sea-level rises are interpreted as the driving mechanism for erosion and aggradation in Arroyo Seco.

  19. 650 nm Laser stimulated dating from Side Antique Theatre, Turkey

    International Nuclear Information System (INIS)

    Doğan, M.; Meriç, N.

    2014-01-01

    Samples were taken from the archeological excavation site, which was at the backs of the Side Antique Theatre. Samples were taken from under the base rock in this area. Polymineral fine grains were examined to determine the ages of the sediments. Samples gathered from the Side Antique Theatre were investigated through using the SAR method. Firstly, one part of the samples were evaluated by using conventional IRSL reading head model of (ELSEC-9010) which is infrared (880±80 nm) stimulation source with Schott BG39 filter. The IRSL age dating with feldspar minerals, gives a number of overestimated or underestimated age values as a result. A new reading head was proposed with the following configuration attachments for overestimation of equivalent dose rates. Measurements were done with this newly designed red laser stimulating reading head which works with Elsec 9010 OSL age dating system. SAR measurements were performed by (650±10 nm) red laser light source with two Schott BG3 filters. With usage of the new designed reading head; closer results were obtained in comparision with the Antique Theatre′s expected age range. Fading rates were taken into consideration and these corrections were also handled for true age results. - Highlights: • Polymineral fine grain feldspar minerals were used for dating. • Two different reading heads were used to determine equivalent doses. • IR stimulated (880 nm) and laser stimulated (650 nm) dating results were compared

  20. Evaluation of aluminum oxide dosimeters using OSL technique in dosimetry of clinical photon beams on volumetric modulated arc treatment

    International Nuclear Information System (INIS)

    Villani, Daniel

    2017-01-01

    Treatment using Volumetric Modulated Arc Radiation Therapy is the most modern modality of conformational radiotherapy so that, with the overlapping of several fields, the dose distributions provide a perfect conformation to the tumor, reducing the probability of complications in adjacent normal tissues. In this sense, many efforts are being invested to improve dose distribution compliance as well as the integration of imaging techniques for tumor screening and correction of inter and intrafraction variations. To this end, an intensive monitoring of the quality of the processes and a quality assurance program are fundamental for patient safety and compliance with current legislation; besides the use of different dosimetry methodologies for intercomparison and validation of the results. The aim of this study is to evaluate and compare the performance of aluminum oxide (Al_2O_3:C) OSL dosimeters manufactured by Landauer Inc. with those produced by Rexon™ in the dosimetry of high energy photon clinical bundles used in Volumetric Modulated Arc Therapy - (VMAT) using different simulating objects. The dosimeters were characterized for gamma radiation of the "6"0Co and for clinical photon beams of 6 MV typical of treatments by VMAT under conditions of electronic equilibrium and maximum dose respectively. Performance tests of the TL and OSL readers used and repeatability of the samples were evaluated. After all tests, the dosimeters were irradiated in the simulation of different radiotherapy treatments by VMAT and their responses compared to the planning system. All types of dosimeters presented satisfactory results in verifying the doses of this type of planning simulation. The Al_2O_3:C dosimeters presented compatible results and validated by the other dosimeters and ionization chamber. Regarding the best technique, the OSL InLight commercial system presents greater practicality and versatility for use and application in the clinical routine. (author)