WorldWideScience

Sample records for orbital tumors concepts

  1. Orbital Chondroma: A rare mesenchymal tumor of orbit

    Directory of Open Access Journals (Sweden)

    Ruchi S Kabra

    2015-01-01

    Full Text Available While relatively common in the skeletal system, cartilaginous tumors are rarely seen originating from the orbit. Here, we report a rare case of an orbital chondroma. A 27-year-old male patient presented with a painless hard mass in the superonasal quadrant (SNQ of left orbit since 3 months. On examination, best-corrected visual acuity of both eyes was 20/20, with normal anterior and posterior segment with full movements of eyeballs and normal intraocular pressure. Computerized tomography scan revealed well defined soft tissue density lesion in SNQ of left orbit. Patient was operated for anteromedial orbitotomy under general anesthesia. Mass was excised intact and sent for histopathological examination (HPE. HPE report showed lobular aggregates of benign cartilaginous cells with mild atypia suggesting of benign cartilaginous tumor - chondroma. Very few cases of orbital chondroma have been reported in literature so far.

  2. Computed tomography of the orbital tumors

    International Nuclear Information System (INIS)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck; Ahn, Byeong Yeob

    1987-01-01

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  3. Computed tomography of the orbital tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of); Ahn, Byeong Yeob [Han Mi Hospital, Seoul (Korea, Republic of)

    1987-04-15

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  4. Tumors of protective system of eye, eyeball and orbit

    International Nuclear Information System (INIS)

    Vajnshtejn, E.S.; Brovkina, A.F.; Burdyanskaya, E.I.; Zarubej, G.D.

    1985-01-01

    Peculiarities of eyelid tissues, eyeball and orbit reaction on ionizing radiation are considered. Methods of radiotherapy in ophthalmology - X-ray therapy, gamma therapy, beta therapy - used for treatment of eyelid tumors, tumors of tear secretion tracts, epibulbar tumors, intraocular tumors, and orbit tumors, are described

  5. Multiple brown tumors of the orbital walls: case report Tumor marrom múltiplo das paredes orbitárias: relato de caso

    Directory of Open Access Journals (Sweden)

    Mário Luiz Ribeiro Monteiro

    2009-02-01

    Full Text Available We report the case of a 40-year-old woman with chronic renal failure and secondary hyperparathyroidism that presented with slowly progressive proptosis of the right eye and mass sensation in the temporal and frontal orbital margins. Computerized tomography scan revealed two separate hyperdense and well-circumscribed lesions in the right orbital walls. A biopsy followed by histopathologic study revealed a dense lesion, with fibrous proliferation associated with osseous metaplasia and osteoclastic activity in the tumor, compatible with the diagnosis of brown tumor. The patient was submitted to surgical removal of the parathyroid glands that resulted in marked improvement in her condition and regression of the orbital tumors. Although the occurrence of more than one separate bone lesion in the orbit usually suggests metastasis, our case shows that brown tumors should also be included in the differential diagnosis of such lesions, particularly in patients with hyperparathyroidism.Este trabalho relata o caso de uma paciente de 40 anos, com insuficiência renal crônica e hiperparatireoidismo secundário que se apresentou com proptose progressiva e tumoração nas regiões lateral da órbita e superior da órbita. Tomografia computadorizada revelou duas lesões ósseas separadas, bem delimitadas e hiperdensas nas paredes orbitárias. Uma biópsia seguida de estudo histopatológico revelou um tumor denso, com proliferação fibrosa associada a metaplasia óssea e atividade osteoclástica no tumor, características compatíveis com tumor marrom. A paciente foi submetida a remoção das glândulas paratiróides que resultou em melhora dramática do seu estado geral e regressão dos tumores orbitais. Embora a presença de mais de uma lesão óssea separada na órbita geralmente sugira o diagnóstico de lesões metastáticas, nosso caso evidencia que tumores marrons devem também ser incluídos no diagnóstico diferencial, particularmente em pacientes com

  6. A GIANT CONGENITAL ORBITAL TUMOR - AN UNUSUAL PRESENTATION OF RETINOBLASTOMA

    NARCIS (Netherlands)

    ZWAAN, CM; DEWAAL, FC; KOOLE, FD; MENKO, FH; VANDERVALK, P; SLATER, RM; SCHEFFER, H; VANWAVEREN, G; MOLL, AC; SCHOUTENVANMEETEREN, AYN; TAN, KEWP

    1994-01-01

    We report a case of an unusual giant congential tumor presenting in a newborn infant as a large exophytic mass emerging from the left orbit. After enucleation orbital recurrence developed within 14 days. No anti-tumor treatment was given and the child died at the age of 4 weeks. The

  7. Orbital Tumors Excision without Bony Marginotomy under Local and General Anesthesia

    Directory of Open Access Journals (Sweden)

    Robert A. Goldberg

    2014-01-01

    Full Text Available To present our experience of removing middle to deep orbital tumors using a combination of minimally invasive soft tissue approaches, sometimes under local anesthesia. Methods. In this retrospective case series, 30 patients (13 males and 17 females underwent tumor removal through eyelid crease (17 eyes, conjunctival (nine eyes, lateral canthal (two eyes, and transcaruncular (two eyes approaches. All tumors were located in the posterior half of the orbit. Six cases were removed under monitored anesthesia care with local block, and 24 were under general anesthesia. Results. The median (range age and follow-up duration were 48.5 (31–87 years old and 24.5 (4–375 weeks, respectively. Visual acuity and ocular motility showed improvement or no significant change in all but one patient at the latest followup. Confirmed pathologies revealed cavernous hemangioma (15 cases, pleomorphic adenoma (5 cases, solitary fibrous tumor (4 cases, neurofibroma (2 cases, schwannoma (2 cases, and orbital varix (1 case. None of the patients experienced recurrence. Conclusions. Creating a bony marginotomy increases intraoperative exposure of the deep orbit but adds substantial time and morbidity. Benign orbital tumors can often be removed safely through small soft-tissue incisions, without bone removal and under local anesthesia.

  8. Clinical and Treatment Features of Orbital Neurogenic Tumors

    Directory of Open Access Journals (Sweden)

    Pınar Bingöl Kızıltunç

    2013-10-01

    Full Text Available Purpose: To evaluate the clinical and treatment features of orbital neurogenic tumors. Material and Method: The records of 35 patients with orbital neurogenic tumors who were diagnosed and treated at Ankara University Faculty of Medicine, Department of Ophthalmology, between 1998 and 2011 were evaluated retrospectively. Results: Orbitotomy via a cutaneous approach was performed in 21 (60% cases and orbitotomy via a transconjunctival approach was performed in 7 (20% cases. Three (8% cases had been operated at different centers. Four (12% cases were diagnosed clinically. Total excisional biopsy was performed in 11 (31.4% cases, subtotal excisional biopsy was performed in 7 (20%, and incisional biopsy was performed in 10 (28.6% cases. 14 (40% 35 cases were diagnosed as meningioma, 12 (34% as peripheral nerve sheath tumor, and 9 (26% cases were diagnosed as optic nerve glioma. Six (43% meningioma cases were optic nerve sheath meningioma, 5 (36% were sphenoid wing meningioma, 2 (14% were ectopic meningioma, and 1 (7% was perisellar meningioma. Six (50% of peripheral nerve sheath tumors were schwannoma, 2 (16% were solitary neurofibroma, 4 (34% were plexiform neurofibroma. External beam radiotherapy was performed in 15 (42.8% cases, cyberknife radiosurgery in 1 (2.8% , chemotherapy in 1 (2.8%, and enucleation ( because of neovascular glaucoma and vitreous hemorrhage was performed in 1 (2.8% case. Discussion: The most common orbital neurogenic tumors are meningioma, peripheral nerve sheath tumor, and optic nerve glioma. For meningioma and glioma, external beam radiotherapy is required; for schwannoma and solitary neurofibroma, total excisional biopsy is the preferred treatment. The success of visual and anatomic results are high after treatment. (Turk J Ophthalmol 2013; 43: 335-9

  9. An Overview of the Jupiter Europa Orbiter Concept's Europa Science Phase Orbit Design

    Science.gov (United States)

    Lock, Robert E.; Ludwinski, Jan M.; Petropoulos, Anastassios E.; Clark, Karla B.; Pappalardo, Robert T.

    2009-01-01

    Jupiter Europa Orbiter (JEO), the proposed NASA element of the proposed joint NASA-ESA Europa Jupiter System Mission (EJSM), could launch in February 2020 and conceivably arrive at Jupiter in December of 2025. The concept is to perform a multi-year study of Europa and the Jupiter system, including 30 months of Jupiter system science and a comprehensive Europa orbit phase of 9 months. This paper provides an overview of the JEO concept and describes the Europa Science phase orbit design and the related science priorities, model pay-load and operations scenarios needed to conduct the Europa Science phase. This overview is for planning and discussion purposes only.

  10. CT and MRI evaluation of orbital tumors: our experience

    International Nuclear Information System (INIS)

    Cabrini, Marcelo; Docampo, Jorge; Martinez, Manuel; Bruno, Claudio; Morales, Carlos

    2007-01-01

    Purpose: To show our experience in the evaluation of orbital masses on computed tomography (CT) and magnetic resonance imaging (MRI). To describe their most important findings and epidemiological features found on literature review, related to their differential diagnosis. Materials and methods: During a 48-months period of time, 26 patients (13 male, 13 female; age range, 3 to 75 years) with orbital tumors were evaluated. Seventeen patients underwent MR scans, 8 underwent CT scans, and one underwent both imaging methods. It was employed 0,5 and 1 Tesla MR scanners, and axial-helical CT scanners. Results: Benign lesions were found on 7 patients (cavernous hemangioma [n=2], meningioma [n=1], epidermoid cyst [n=1], dermoid cyst [n=1], lipoma [n=1], orbital vein deformity [n=1]). It was found lesions with undetermined behavior (optical nerve glioma [n=2]), and malignant ones were found on 17 patients (metastatic lesions [n=5], non- Hodgkin's lymphoma [n=3], hemangiopericytoma [n=2], retinoblastoma [n=2], rhabdomyosarcoma [n=2], melanoma [n=1], and lacrimal adenocarcinoma [n=1]). Conclusion: In our experience, 65.4% was malignant tumors (orbital metastasis was the most common; 19.2%). More than one-quarter was benign tumor, where cavernous hemangioma was the most frequent. (author) [es

  11. A SOLITARY FIBROUS ORBITAL TUMOR IN A PATIENT WITH NEUROFIBROMATOSIS AND AN UTERINE CARCINOMA

    Directory of Open Access Journals (Sweden)

    E. E. Grishina

    2016-01-01

    Full Text Available We present a rare combination of a solitary fibrous orbital tumor and uterine cancer in a  female patient with type I  neurofibromatosis. This 77-year old patient developed a  left painless exophthalmos within 2 years and decreased visual acuity of the left eye. At the age of 20  she was diagnosed with type I neurofibromatosis. Half a year ago she underwent hysteron-oophorectomy due to uterine adenocarcinoma. The visual acuity of her left eye was decreased to 0.3, with an increase of intraocular pressure to 30 mm Hg. She had a 13-mm left-sided exophthalmos with misplacement of the eye downwards and laterally at 40°. Reposition of the left eye was severely impaired, with limitation of the eye movements to all directions. Ophthalmoscopy showed optic disc discoloration and blunting of its inner border. The patient underwent trans-conjunctival orbitotomy, with removal of three encapsulated tumor nodules. Histological and immunochemical studies of the removed tissue identified solitary fibrous tumor of the left orbit with an undetermined malignant potential. In the post-operative period, visual acuity of the left eye was 0.2, with no exophthalmos and right position of the eye. There was a non-significant limitation of the left eye movement to the left and to the right. X-ray computed tomography confirmed radical tumor excision. Conclusion: Solitary fibrous tumor is a  rare orbital neoplasm. Nevertheless, it should be included into the differential diagnosis list of spin-cell orbital tumors. It is necessary to aim at tumor removal through the least traumatic orbital access. Relapsing course of the tumor is the rationale for a  long-term follow-up of patients after removal of solitary fibrous orbital tumor.

  12. A Multidisciplinary Orbit-Sparing Treatment Approach That Includes Proton Therapy for Epithelial Tumors of the Orbit and Ocular Adnexa

    Energy Technology Data Exchange (ETDEWEB)

    Holliday, Emma B. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Esmaeli, Bita [Orbital Oncology and Ophthalmic Plastic Surgery Program, Department of Plastic Surgery, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Pinckard, Jamie [School of Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, Texas (United States); Garden, Adam S.; Rosenthal, David I.; Morrison, William H. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Kies, Merrill S. [Department of Thoracic/Head and Neck Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Gunn, G. Brandon; Fuller, C. David; Phan, Jack; Beadle, Beth M. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Zhu, Xiarong Ronald; Zhang, Xiaodong [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Frank, Steven J., E-mail: sjfrank@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2016-05-01

    Purpose: Postoperative radiation is often indicated in the treatment of malignant epithelial tumors of the orbit and ocular adnexa. We present details of radiation technique and toxicity data after orbit-sparing surgery followed by adjuvant proton radiation therapy. Methods and Materials: Twenty patients underwent orbit-sparing surgery followed by proton therapy for newly diagnosed malignant epithelial tumors of the lacrimal gland (n=7), lacrimal sac/nasolacrimal duct (n=10), or eyelid (n=3). Tumor characteristics, treatment details, and visual outcomes were obtained from medical records. Acute and chronic toxicity were prospectively scored using Common Terminology Criteria for Adverse Events version 4.0. Results: The median radiation dose was 60 Gy(RBE) (relative biological effectiveness; [range 50-70 Gy]); 11 patients received concurrent chemotherapy. Dose to ipsilateral anterior optic structures was reduced in 13 patients by having them gaze away from the target during treatment. At a median follow-up time of 27.1 months (range 2.6-77.2 months), no patient had experienced local recurrence; 1 had regional and 1 had distant recurrence. Three patients developed chronic grade 3 epiphora, and 3 developed grade 3 exposure keratopathy. Four patients experienced a decrease in visual acuity from baseline but maintained vision sufficient to perform all activities of daily living without difficulty. Patients with grade ≥3 chronic ocular toxicity had higher maximum dose to the ipsilateral cornea (median 46.3 Gy[RBE], range 36.6-52.7 Gy[RBE] vs median 37.4 Gy[RBE], range 9.0-47.3 Gy(RBE); P=.017). Conclusions: Orbit-sparing surgery for epithelial tumors of the orbit and ocular adnexa followed by proton therapy successfully achieved disease control and was well tolerated. No patient required orbital exenteration or enucleation. Chronic grade 3 toxicity was associated with high maximum dose to the cornea. An eye-deviation technique can be used to limit the maximum

  13. Metastatic neuroendocrine tumor with initial presentation of orbital apex syndrome

    Directory of Open Access Journals (Sweden)

    Yen-Yu Huang

    2017-03-01

    Full Text Available The possible etiologies of orbital apex syndrome range from inflammatory, infectious, neoplastic, iatrogenic/traumatic, to vascular processes. In patients without obvious infection or systemic cancer history, judicious use of corticosteroids is a reasonable strategy. We describe a 64-year-old man who presented with orbital apex syndrome and had progressed to total visual loss in three days after admission. Radiological imaging and pathological studies were consistent with a neuroendocrine tumor with multiple metastases. We recommend that a biopsy-proven specimen is warranted in patient with orbital apex syndrome even without a cancer history.

  14. Two- versus four-handed techniques for endonasal resection of orbital apex tumors.

    Science.gov (United States)

    Craig, John R; Lee, John Y K; Petrov, Dmitriy; Mehta, Sonul; Palmer, James N; Adappa, Nithin D

    2015-01-01

    Open versus endonasal resection of orbital apex (OA) tumors is generally based on tumor size, location, and pathology. For endonasal resection, two- and four-handed techniques have been reported, but whether one technique is more optimal based on these tumor features has not been evaluated. To determine whether two- versus four-handed techniques result in better outcomes after endoscopic resection of OA tumors, and whether either technique is better suited for intra- versus extraconal location and for benign versus malignant pathology. A retrospective review of all expanded endonasal approaches for OA tumors was performed at a single institution from 2009 to 2013. A PubMed database search was also performed to review series published on endonasal OA tumor resection. Across all the cases reviewed, the following data were recorded: two- versus four-handed techniques, intra- versus extraconal tumor location, and benign versus malignant pathology. The relationship between these variables and resection extent was analyzed by the Fisher exact test. Postoperative visual status and complications were also reviewed. Ten cases from the institution and 94 cases from 17 publications were reviewed. Both two- and four-handed techniques were used to resect extra- and intraconal OA tumors, for both benign and malignant pathology. Four-handed techniques included a purely endonasal approach and a combined endonasal-orbital approach. On univariate analysis, the strongest predictor of complete resection was benign pathology (p = 0.005). No significant difference was found between the extent of resection and a two- versus a four-handed technique. Visual status was improved or unchanged in 94% of cases, and other complications were rare. Benign tumors that involve the medial extraconal and posterior inferomedial intraconal OA can be treated by either two- or four-handed endonasal techniques. Selecting two- versus four-handed techniques and endonasal versus endonasal-orbital four

  15. Ultrasonography and computed tomography in the study of orbital tumors and pseudo-tumoral lesions

    International Nuclear Information System (INIS)

    Marins, J.L.C.; Pereira, R.M.; Prando, A.; Selos Moreira, A.R. de

    1987-01-01

    The computerized tomography and the ultrasonography in the ocular and orbital patologies were considered as complementary each other. the ultrasonography method as choice for the detection of the eye lesions in the adult, particularly of vascular origin and in the follow-up of inflammatory and pseudo-tumoral lesions was chosen. (L.M.J.) [pt

  16. Orbital melanocytoma: When a tumor becomes a relieving surprise

    Directory of Open Access Journals (Sweden)

    Haytham E. Nasr

    2018-06-01

    Full Text Available Purpose: Melanocytomas are rare pigmented tumors that arise form melanocytes and have been reported in the central nervous system. Orbital melanocytomas “also known as blue nevus” are rarely reported. The occurrence of choroidal melanoma and orbital melanocytomas has never been described. Observations: This is a case of orbital melanocytoma in a 34 year old female who presented with left proptosis and ecchymosis. She has the right eye enucleated to treat a large choroidal melanoma, 6 years earlier. Orbital metastasis was suspected. After orbital imaging and systemic evaluation, incisional biopsy was planned yet the mass could be totally excised and it turned out to be melanocytoma. The condition was not associated with nevus of Ota and the patient is not known to have any predisposing condition for melanocytic lesions. Conclusion and importance: Melanocytoma and malignant melanoma share the same cell of origin. The benign course, the well differentiated cells, absence of anaplasia and the positive reaction to Human Melanoma Black-45 (HMB-45 and S-100 proteins established the diagnosis of the former. Such diagnosis was a relief for this one eyed patient.(HMB-45:human melanoma black-45. Keywords: Orbit, Melanocytoma, Choroidal melanoma, HMB-45, S-100

  17. [Bilateral anophthalmia and left-sided orbital tumor : case of an eight-month-old infant].

    Science.gov (United States)

    Hundertmark, P; Dierks, P; Gottschalk, J; Kreusch, T; Wiegand, W

    2011-08-01

    An 8-month-old infant from Russia with bilateral anophthalmia presented with an expanding orbital tumor. The tumor was extirpated and the histological examination revealed a non-malignant pseudocystic process with residual neuro-ectodermal structures.

  18. GNSS-R concept extended by a fine orbit tuning

    Czech Academy of Sciences Publication Activity Database

    Klokočník, Jaroslav; Bezděk, Aleš; Kostelecký, J.

    2012-01-01

    Roč. 49, č. 5 (2012), s. 957-965 ISSN 0273-1177 Institutional support: RVO:67985815 Keywords : bistatic altimetry * PARIS concept * orbit resonances Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.183, year: 2012

  19. RS-34 (Peacekeeper Post Boost Propulsion System) Orbital Debris Application Concept Study

    Science.gov (United States)

    Esther, Elizabeth A.; Burnside, Christopher G.

    2013-01-01

    The Advanced Concepts Office (ACO) at the NASA Marshall Space Flight Center (MSFC) lead a study to evaluate the Rocketdyne produced RS-34 propulsion system as it applies to an orbital debris removal design reference mission. The existing RS-34 propulsion system is a remaining asset from the de-commissioned United States Air Force Peacekeeper ICBM program; specifically the pressure-fed storable bi-propellant Stage IV Post Boost Propulsion System. MSFC gained experience with the RS-34 propulsion system on the successful Ares I-X flight test program flown in the Ares I-X Roll control system (RoCS). The heritage hardware proved extremely robust and reliable and sparked interest for further utilization on other potential in-space applications. Subsequently, MSFC is working closely with the USAF to obtain all the remaining RS-34 stages for re-use opportunities. Prior to pursuit of securing the hardware, MSFC commissioned the Advanced Concepts Office to understand the capability and potential applications for the RS-34 Phoenix stage as it benefits NASA, DoD, and commercial industry. Originally designed, the RS-34 Phoenix provided in-space six-degrees-of freedom operational maneuvering to deploy multiple payloads at various orbital locations. The RS-34 Concept Study, preceded by a utilization study to understand how the unique capabilities of the RS-34 Phoenix and its application to six candidate missions, sought to further understand application for an orbital debris design reference mission as the orbital debris removal mission was found to closely mimic the heritage RS-34 mission. The RS-34 Orbital Debris Application Concept Study sought to identify multiple configurations varying the degree of modification to trade for dry mass optimization and propellant load for overall capability and evaluation of several candidate missions. The results of the RS-34 Phoenix Utilization Study show that the system is technically sufficient to successfully support all of the missions

  20. Complicações oftálmicas em pacientes com tumores malignos extra-orbitários Ophthalmic complications in patients with extraorbital malignant tumors

    Directory of Open Access Journals (Sweden)

    Ana Célia Baptista

    2003-10-01

    Full Text Available OBJETIVO: Correlacionar as complicações oftálmicas, presentes em pacientes portadores de tumores malignos extra-orbitários, com o sítio de origem e diagnóstico histopatológico destas neoplasias, por meio de tomografia computadorizada. MÉTODOS: Foram estudados retrospectivamente, por tomografia computadorizada, 29 pacientes com neoplasias malignas extra-orbitárias, sem qualquer tratamento prévio do tumor, e evidência clínico-radiológica de comprometimento orbitário associado. RESULTADOS: Houve predomínio do carcinoma epidermóide (28%, seguido pelo carcinoma basocelular (14%. As complicações oftálmicas mais comumente observadas foram proptose (38%, epífora (24% e dor ocular (24%. Redução da acuidade visual foi referida em 14 % dos casos. Os sítios de origem mais comuns das neoplasias foram o seio maxilar (28%, o seio etmoidal (17% e a pele e subcutâneo da face (17%. Proptose ocular foi causada predominantemente por tumores não carcinomatosos e tumores originados no seio etmoidal, ao passo que epífora ocorreu preferencialmente nos casos de tumores carcinomatosos e de neoplasias do seio maxilar. Redução da motilidade ocular, irritação ocular e secreção no olho foram as complicações oftálmicas mais freqüentes em pacientes com tumores dos anexos oculares, ao passo que dor ocular foi a complicação oftálmica dominante nos pacientes com neoplasias originadas na pele e subcutâneo da face. CONCLUSÕES: Os autores sugerem que, diante de paciente com epífora e massa maxilo-nasal, carcinoma do seio maxilar deve ser considerado primariamente no diagnóstico diferencial da lesão. Da mesma forma, tumores não carcinomatosos, como sarcomas e linfomas, devem ser considerados, sobretudo no diagnóstico de pacientes com proptose e massa naso-etmoidal.OBJECTIVE: To correlate the ophthalmic complications in patients with extra-orbital malignant tumors with the site of origin and histopathologic diagnosis of the tumors by

  1. Role of TPS in 125I brachytherapy for orbital tumors

    International Nuclear Information System (INIS)

    Ren Ling; Dai Haojie; Li Quan

    2012-01-01

    Objective: To investigate the role of TPS in 125 I brachytherapy for orbital tumors. Methods: Sixty-six patients with orbital tumor treated with 125 I seeds from 2005 to 2009 were retrospectively analyzed. Forty-three patients were treated using TPS guided brachytherapy and the prescribed dose was 140 Gy. Other 23 patients were treated without TPS but simply implanted with 125 I seeds at 1 cm intervals in parallel with each other intraoperatively. CT and TPS quality verification were performed postoperatively in all patients. Also, CT and (or) MRI examination were performed at 3, 6, 12 and 24 months after brachytherapy for follow-up. χ 2 test and Kaplan-Meier survival analysis with log-rank significance test were used with SPSS 17.0. Results: A total of 1070 125 I seeds were implanted in 66 cases, on average, (16.2 ± 7.3) seeds for each patient. The satisfaction rates of postoperative quality verification in patients with and without TPS pre-plans were 79.07% (34/43) and 43.48% (10/23) respectively (χ 2 =8.542, P=0.003). Ten patients were lost in follow-up. Local recurrence rates in patients with favorable postoperative quality verification were 0 (0/37) in 3 months, 6.25% (2/32) in 6 months, 13.64% (3/22) in 12 months and 3/9 in 24 months respectively, which were significantly different from those (5.26% (1/19), 16.67% (3/18), 30.77% (4/13), 6/6) in the patients with inferior postoperative quality verification (χ 2 =9.017, P=0.0003). Conclusions: TPS plays an important role in 125 I brachytherapy for orbital tumors. Also, postoperative quality verification by TPS may help predict the local recurrence after brachytherapy. (authors)

  2. CT-criteria of orbital hemangiomas and their importance in differential diagnosis of intraconal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Unsoeld, R; Hoyt, W F [California Univ., San Francisco (USA). Dept. of Neurosurgery; California Univ., San Francisco (USA). Dept. of Neurology and Opthalmology; California Univ., San Francisco (USA). Dept. of Neuroradiology)

    1979-12-01

    CT-Scans of 29 histologically proven cavernous hemangiomas were evaluated with respect to their location, shape, delineation from surrounding tissue, contrast-enhancement, and secondary changes of the bony orbit. Whenever a round or oval tumor, located in the outer upper muscle cone, sharply delineated from surrounding tissue, unattached to optic nerve and ocular muscles, spares a small triangular space in the orbital apex, it is in all probability a cavernous hemangioma. Evaluation of the tumors shape and its separation from surrounding tissues requires imaging in multiple sections in two planes oriented, if possible, at right angles. Changes in position of the optic nerve and eye muscles in different directions of gaze demonstrated by CT rule out significant tumor-attachments. The portion of the intraconal space least affected by optic nerve shifts and muscle contractions during eye movements, as demonstrated by CT, is the upper outer quadrant, the site preferred by the mobile tumor. Tumors which cannot be differentiated from cavernous hemangiomas by CT-criteria are rare usually benign. Reports of rare examples of well delineated or encapsulated malignant intraconal lesions indicate the possibility - however remote - of mistaking a malignant tumor for a cavernous hemangioma by CT.

  3. Development of preliminary design concept for a multifunction display and control system for the Orbiter crew station. Task 4: Design concept recommendation

    Science.gov (United States)

    Spiger, R. J.; Farrell, R. J.; Holcomb, G. A.

    1982-01-01

    Application of multifunction display and control systems to the NASA Orbiter spacecraft offers the potential for reducing crew workload and improving the presentation of system status and operational data to the crew. A design concept is presented for the application of a multifunction display and control system (MFDCS) to the Orbital Maneuvering System and Electrical Power Distribution and Control System on the Orbiter spacecraft. The MFDCS would provide the capability for automation of procedures, fault prioritization and software reconfiguration of the MFDCS data base. The MFDCS would operate as a stand-alone processor to minimize the impact on the current Orbiter software. Supervisory crew command of all current functions would be retained through the use of several operating modes in the system. Both the design concept and the processes followed in defining the concept are described.

  4. Concept design and alternate arrangements of orbiter mid-deck habitability features

    Science.gov (United States)

    Church, R. A.; Ciciora, J. A.; Porter, K. L.; Stevenson, G. E.

    1976-01-01

    The evaluations and recommendations for habitability features in the space shuttle orbiter mid-deck are summarized. The orbiter mission plans, the mid-deck dimensions and baseline arrangements along with crew compliments and typical activities were defined. Female and male anthropometric data based on zero-g operations were also defined. Evaluations of baseline and alternate feasible concepts provided several recommendations which are discussed.

  5. A Concept of Two-Stage-To-Orbit Reusable Launch Vehicle

    Science.gov (United States)

    Yang, Yong; Wang, Xiaojun; Tang, Yihua

    2002-01-01

    Reusable Launch Vehicle (RLV) has a capability of delivering a wide rang of payload to earth orbit with greater reliability, lower cost, more flexibility and operability than any of today's launch vehicles. It is the goal of future space transportation systems. Past experience on single stage to orbit (SSTO) RLVs, such as NASA's NASP project, which aims at developing an rocket-based combined-cycle (RBCC) airplane and X-33, which aims at developing a rocket RLV, indicates that SSTO RLV can not be realized in the next few years based on the state-of-the-art technologies. This paper presents a concept of all rocket two-stage-to-orbit (TSTO) reusable launch vehicle. The TSTO RLV comprises an orbiter and a booster stage. The orbiter is mounted on the top of the booster stage. The TSTO RLV takes off vertically. At the altitude about 50km the booster stage is separated from the orbiter, returns and lands by parachutes and airbags, or lands horizontally by means of its own propulsion system. The orbiter continues its ascent flight and delivers the payload into LEO orbit. After completing orbit mission, the orbiter will reenter into the atmosphere, automatically fly to the ground base and finally horizontally land on the runway. TSTO RLV has less technology difficulties and risk than SSTO, and maybe the practical approach to the RLV in the near future.

  6. Development of an EVA systems cost model. Volume 2: Shuttle orbiter crew and equipment translation concepts and EVA workstation concept development and integration

    Science.gov (United States)

    1975-01-01

    EVA crewman/equipment translational concepts are developed for a shuttle orbiter payload application. Also considered are EVA workstation systems to meet orbiter and payload requirements for integration of workstations into candidate orbiter payload worksites.

  7. Current concepts of salivary gland tumors

    Directory of Open Access Journals (Sweden)

    Raj Kumar Badam

    2015-01-01

    Full Text Available The embryonic development of salivary glands is a complex process that creates compact, highly organized secretory organs with functions essential for oral health. The development is an example of branching morphogenesis, recent research found to involve unexpectedly dynamic cell motility, and novel regulatory pathways. Numerous growth factors, extracellular matrix molecules, gene regulatory pathways, and mechanical forces contribute to salivary gland morphogenesis, but local gene regulation and morphological changes appear to play particularly notable roles. Salivary gland tumors are one of the most complex and relatively rare groups of lesions encountered in oral pathology practice. Their complexity is attributed to the heterogeneity of the cells of origin of these lesions. Frequent overlap of microscopic features among various neoplasms makes us sometimes even to differentiate benign and malignant lesions leading to a diagnostic dilemma. Here, we review and summarize the current concepts regarding the histogenetic and morphogenetic concepts of salivary gland tumors and their relevance to routine diagnosis and classification of these lesions.

  8. Orbital transfer vehicle concept definition and system analysis study. Volume 2: OTV concept definition and evaluation. Book 1: Mission and system requirements

    Science.gov (United States)

    Kofal, Allen E.

    1987-01-01

    The mission and system requirements for the concept definition and system analysis of the Orbital Transfer Vehicle (OTV) are established. The requirements set forth constitute the single authority for the selection, evaluation, and optimization of the technical performance and design of the OTV. This requirements document forms the basis for the Ground and Space Based OTV concept definition analyses and establishes the physical, functional, performance and design relationships to STS, Space Station, Orbital Maneuvering Vehicle (OMV), and payloads.

  9. Solitary fibrous tumor of the orbit presenting in pregnancy

    Directory of Open Access Journals (Sweden)

    Das Jayanta

    2009-01-01

    Full Text Available A 32-year-old woman, three months pregnant, reported with the complaint of protrusion of the right eye for six months. She gave history of rapid protrusion of eyeball for the last two months along with the history of double vision for the last one month. Computer tomography (CT scan revealed a well-defined mass lesion in the intraconal space of the right orbit which was excised through a lateral orbitotomy approach. Histological examination and immunohistochemistry revealed a solitary fibrous tumor, which showed a rapid progression in pregnancy.

  10. Concept Design of the Payload Handling Manipulator System. [space shuttle orbiters

    Science.gov (United States)

    1975-01-01

    The design, requirements, and interface definition of a remote manipulator system developed to handle orbiter payloads are presented. End effector design, control system concepts, and man-machine engineering are considered along with crew station requirements and closed circuit television system performance requirements.

  11. Malignant perivascular epithelioid cell tumor of the orbit: Report of a case and review of literature

    Directory of Open Access Journals (Sweden)

    Md Shahid Alam

    2017-01-01

    Full Text Available Perivascular epithelioid cell tumor (PEComa is a rare neoplasm considered to arise from myomelanocytic cell lineage. The uterus is reportedly the most common site to be involved. Orbital PEComa is extremely rare with only two cases reported till date. A 5-year-old male presented with a right medial orbital mass for the last 6 months. The patient was diagnosed with alveolar soft part sarcoma elsewhere. Magnetic resonance imaging features were suggestive of lymphangioma with bleeding. The excision biopsy revealed multiple tumor cells comprising epithelioid cells with clear cytoplasm, along with nuclear atypia and mitosis. Immunohistochemistry was positive for HMB-45, smooth muscle actin, vimentin, and CD-34. It was negative for cytokeratin, S-100, and synaptophysin, which clinched the diagnosis of malignant orbital PEComa. Neoadjuvant chemotherapy was administered. There was no recurrence at 24 months of follow-up. At present, there is no consensus on management protocol for malignant PEComa. Complete surgical excision with chemotherapy appears to offer the best prognosis.

  12. Endoscopic trans-nasal approach for biopsy of orbital tumors using image-guided neuro-navigation system

    International Nuclear Information System (INIS)

    Sieskiewicz, A.; Mariak, Z.; Rogowski, M.; Lyson, T.

    2008-01-01

    Histopathological diagnosis of intraorbital tumors is of crucial value for planning further therapy. The aim of the study was to explore clinical utility of image-guided endoscopy for biopsy of orbital tumors. Trans-nasal endoscopic biopsy of intraorbital mass lesions was performed in 6 patients using a neuro-navigation system (Medtronic Stealth Station Treon plus). The CT and MRI 1 mm slice images were fused by the system in order to visualise both bony and soft tissue structures. The anatomic fiducial registration protocol was used during the procedure. All lesions were precisely localised and the biopsies could be taken from the representative part of the pathological mass. None of the patients developed aggravation of ocular symptoms after the procedure. The operative corridor as well as the size of orbital wall fenestration could be limited to a minimum. The accuracy of neuro-navigation remained high and stable during the entire procedure. The image-guided neuro-navigation system facilitated endoscopic localisation and biopsy of intraorbital tumors and contributed to the reduction of surgical trauma during the procedure. The technique was particularly useful in small, medially located, retrobulbar tumors and in unclear situations when the structure of the lesion resembled surrounding intraorbital tissue. (author)

  13. Exploring Europa's Habitability: Science achieved from the Europa Orbiter and Clipper Mission Concepts

    Science.gov (United States)

    Senske, D. A.; Prockter, L. M.; Pappalardo, R. T.; Patterson, G. W.; Vance, S.

    2012-12-01

    Europa is a prime candidate in the search for present-day habitable environments in our solar system. Europa is unique among the large icy satellites because it probably has a saltwater ocean today beneath an ice shell that is geodynamically active. The combination of irradiation of its surface and tidal heating of its interior could make Europa a rich source of chemical energy for life. Perhaps most importantly, Europa's ocean is believed to be in direct contact with its rocky mantle, where conditions could be similar to those on Earth's biologically rich sea floor. Hydrothermal zones on Earth's seafloor are known to be rich with life, powered by energy and nutrients that result from reactions between the seawater and the warm rocky ocean floor. Life as we know it depends on three principal "ingredients": 1) a sustained liquid water environment; 2) essential chemical elements that are critical for building life; and 3) a source of energy that could be utilized by life. Europa's habitability requires understanding whether it possesses these three ingredients. NASA has enlisted a study team to consider Europa mission options feasible over the next decade, compatible with NASA's projected planetary science budget and addressing Planetary Decadal Survey priorities. Two Europa mission concepts (Orbiter and multiple flyby—call the "Clipper") are undergoing continued study with the goal to "Explore Europa to investigate its habitability." Each mission would address this goal in complementary ways, with high science value of its own. The Orbiter and Clipper architectures lend themselves to specific types of scientific measurements. The Orbiter concept is tailored to the unique geophysical science that requires being in orbit at Europa. This includes confirming the existence of an ocean and characterizing that ocean through geophysical measurements of Europa's gravitational tides and magnetic induction response. It also includes mapping of the global morphology and

  14. Eye tracking and gating system for proton therapy of orbital tumors

    International Nuclear Information System (INIS)

    Shin, Dongho; Yoo, Seung Hoon; Moon, Sung Ho; Yoon, Myonggeun; Lee, Se Byeong; Park, Sung Yong

    2012-01-01

    Purpose: A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. Methods: We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, Austin, TX). To measure the pixel spacing of an image consistently, four different calibration modes such as the point-detection, the edge-detection, the line-measurement, and the manual measurement mode were suggested and used. After these methods were applied to proton therapy, gating was performed, and radiation dose distributions were evaluated. Results: Moving phantom verification measurements resulted in errors of less than 0.1 mm for given ranges of translation. Dosimetric evaluation of the beam-gating system versus nongated treatment delivery with a moving phantom shows that while there was only 0.83 mm growth in lateral penumbra for gated radiotherapy, there was 4.95 mm growth in lateral penumbra in case of nongated exposure. The analysis from clinical results suggests that the average of eye movements depends distinctively on each patient by showing 0.44 mm, 0.45 mm, and 0.86 mm for three patients, respectively. Conclusions: The developed automatic eye-tracking based beam-gating system enabled us to perform high-precision proton radiotherapy of orbital tumors.

  15. Inflammatory myofibroblastic tumor of the orbit: A clinico-pathological study of 25 cases

    Directory of Open Access Journals (Sweden)

    Diego Strianese

    2018-01-01

    Full Text Available Background: Inflammatory myofibroblastic tumor (IMT is a rare entity characterized by the presence of myofibroblasts and inflammatory cells within a fibrous stroma, which typically occurs in children or young adults. The IMT is considered generally a benign lesion, although about 20% of cases may experience recurrence, and most rarely develop metastasis. Herein, we present the largest series of primary orbital IMT ever reported. Patients and methods: The clinical records of 25 patients, collected between the 1995 and 2015, with biopsy-proven diagnosis of orbital IMT were retrospectively reviewed to determine demographic, clinical, radiologic and pathological features, management, and outcome. Results: The study included 13 females and 12 male patients, age ranged from 5 to 76 years. Disease onset was in all cases unilateral (25/25, with posterior location (10/25 or extending anterior to posterior (7/25. The most common signs and symptoms were: proptosis (19/25, ptosis (18/25, diplopia (10/25, periocular swelling (9/25, pain (8/25, redness (7/25. All patients underwent to incisional biopsy which included total or subtotal tumor resection avoiding arming of the adjacent structure, followed by systemic steroid therapy (22/25 or radiotherapy (3/25. The disease recurred in 6 (24% patients who responded to the subsequent therapy. No one developed metastasis or died because of the disease. Conclusion: IMT is a distinct entity which may occur in the orbit primarily. It should be considered in differential diagnosis in all orbital masses, particularly with onset of acute or subcronic inflammation. Surgical biopsy associated to a partial debulcking of the tumor, avoiding to damage adjacent vital structure may contribute to improve the outcome. Steroid therapy, seems to be the suitable as first line medical therapy, although, as reported in literature, not all cases respond to this treatment regimen. Radiotherapy, may be considered as an alternative

  16. Contrast in low-cost operational concepts for orbiting satellites

    Science.gov (United States)

    Walyus, Keith D.; Reis, James; Bradley, Arthur J.

    2002-12-01

    Older spacecraft missions, especially those in low Earth orbit with telemetry intensive requirements, required round-the-clock control center staffing. The state of technology relied on control center personnel to continually examine data, make decisions, resolve anomalies, and file reports. Hubble Space Telescope (HST) is a prime example of this description. Technological advancements in hardware and software over the last decade have yielded increases in productivity and operational efficiency, which result in lower cost. The re-engineering effort of HST, which has recently concluded, utilized emerging technology to reduce cost and increase productivity. New missions, of which NASA's Transition Region and Coronal Explorer Satellite (TRACE) is an example, have benefited from recent technological advancements and are more cost-effective than when HST was first launched. During its launch (1998) and early orbit phase, the TRACE Flight Operations Team (FOT) employed continually staffed operations. Yet once the mission entered its nominal phase, the FOT reduced their staffing to standard weekday business hours. Operations were still conducted at night and during the weekends, but these operations occurred autonomously without compromising their high standards for data collections. For the HST, which launched in 1990, reduced cost operations will employ a different operational concept, when the spacecraft enters its low-cost phase after its final servicing mission in 2004. Primarily due to the spacecraft"s design, the HST Project has determined that single-shift operations will introduce unacceptable risks for the amount of dollars saved. More importantly, significant cost-savings can still be achieved by changing the operational concept for the FOT, while still maintaining round-the-clock staffing. It"s important to note that the low-cost solutions obtained for one satellite may not be applicable for other satellites. This paper will contrast the differences between

  17. Experimental evaluation of the Skylab orbital workshop ventilation system concept

    Science.gov (United States)

    Allums, S. L.; Hastings, L. J.; Ralston, J. T.

    1972-01-01

    Extensive testing was conducted to evaluate the Orbital Workshop ventilation concept. Component tests were utilized to determine the relationship between operating characteristics at 1 and 0.34 atm. System tests were conducted at 1 atm within the Orbital Workshop full-scale mockup to assess delivered volumetric flow rate and compartment air velocities. Component tests with the Anemostat circular diffusers (plenum- and duct-mounted) demonstrated that the diffuser produced essentially equivalent airflow patterns and velocities in 1- and 0.34-atm environments. The tests also showed that the pressure drop across the diffuser could be scaled from 1 to 0.34 atm using the atmosphere pressure ratio. Fan tests indicated that the performance of a multiple, parallel-mounted fan cluster could be predicted by summing the single-fan flow rates at a given delta P.

  18. Uncommon primary tumors of the orbit diagnosed by computed tomography-guided core needle biopsy: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Matushita Junior, Joao Paulo Kawaoka; Bitencourt, Almir Galvao Vieira; Amoedo, Mauricio Kauark; Barbosa, Paula Nicole Vieira; Chojniak, Rubens, E-mail: almirgvb@yahoo.com.br [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil). Dept. de Imagem; Neves, Flavia Branco Cerqueira Serra [Hospital do Servidor Publico Estadual, Sao Paulo, SP (Brazil). Div. de Oftalmologia

    2014-11-15

    Computed tomography-guided percutaneous biopsy is a safe and effective alternative method for evaluating selected intra-orbital lesions where the preoperative diagnosis is important for the therapeutic planning. The authors describe two cases of patients with uncommon primary orbital tumors whose diagnosis was obtained by means of computed tomography-guided core needle biopsy, with emphasis on the technical aspects of the procedure. (author)

  19. NASA Advanced Concepts Office, Earth-To-Orbit Team Design Process and Tools

    Science.gov (United States)

    Waters, Eric D.; Garcia, Jessica; Threet, Grady E., Jr.; Phillips, Alan

    2013-01-01

    The Earth-to-Orbit Team (ETO) of the Advanced Concepts Office (ACO) at NASA Marshall Space Flight Center (MSFC) is considered the pre-eminent "go-to" group for pre-phase A and phase A concept definition. Over the past several years the ETO team has evaluated thousands of launch vehicle concept variations for a significant number of studies including agency-wide efforts such as the Exploration Systems Architecture Study (ESAS), Constellation, Heavy Lift Launch Vehicle (HLLV), Augustine Report, Heavy Lift Propulsion Technology (HLPT), Human Exploration Framework Team (HEFT), and Space Launch System (SLS). The ACO ETO Team is called upon to address many needs in NASA's design community; some of these are defining extremely large trade-spaces, evaluating advanced technology concepts which have not been addressed by a large majority of the aerospace community, and the rapid turn-around of highly time critical actions. It is the time critical actions, those often limited by schedule or little advanced warning, that have forced the five member ETO team to develop a design process robust enough to handle their current output level in order to meet their customer's needs. Based on the number of vehicle concepts evaluated over the past year this output level averages to four completed vehicle concepts per day. Each of these completed vehicle concepts includes a full mass breakdown of the vehicle to a tertiary level of subsystem components and a vehicle trajectory analysis to determine optimized payload delivery to specified orbital parameters, flight environments, and delta v capability. A structural analysis of the vehicle to determine flight loads based on the trajectory output, material properties, and geometry of the concept is also performed. Due to working in this fast-paced and sometimes rapidly changing environment, the ETO Team has developed a finely tuned process to maximize their delivery capabilities. The objective of this paper is to describe the interfaces

  20. CONGENITAL ORBITAL TERATOMA

    African Journals Online (AJOL)

    was done without contrast and 3mm/5mm/10mm slices were obtained to cover the orbit, skull base and brain. The findings included a soft tissue mass arising from the orbit. The left eye ball was extra orbital. There was no defect .... love's Short Practice of Surgery. 7 Edition,. Levis London, 1997; 45-64. 2. Orbital tumor Part 1, ...

  1. [A Case of an Orbital Angioleiomyoma].

    Science.gov (United States)

    Sato, Kohei; Ogawa, Yukari; Kinoshita, Keita; Takai, Hiroki; Hirai, Satoshi; Ishihara, Manabu; Hara, Keijiro; Toi, Hiroyuki; Matsubara, Shunji; Uno, Masaaki

    2017-12-01

    A 70-year-old woman presented with a 4-year history of painless conjunctival congestion and proptosis of the right eye. Computed tomography and magnetic resonance imaging revealed a 48-mm lesion in the right medial orbit. As the symptoms progressed, the tumor was resected by performing fronto-orbital craniotomy. Histopathological examination revealed a vascular tumor surrounded by smooth muscle fibers and immunohistochemistry demonstrated tumor positivity for smooth muscle actin and desmin. The tumor was diagnosed as an angioleiomyoma, and no recurrence has been observed as of 5 years postoperatively. Angioleiomyomas in the orbit are extremely rare;thus, we have reported this case with reference to the literature.

  2. Value of MR imaging in the differentiation of benign and malignant orbital tumors in adults

    International Nuclear Information System (INIS)

    Xian, Junfang; Zhang, Zhengyu; Wang, Zhenchang; Li, Jing; Yang, Bentao; Man, Fengyuan; Chang, Qinglin; Zhang, Yunting

    2010-01-01

    To prospectively evaluate magnetic resonance (MR) imaging including dynamic contrast-enhanced MR imaging in the differentiation of benign from malignant orbital masses and to evaluate which MR imaging features are most predictive of malignant tumors. The study was approved by the institutional review board and signed informed consent was obtained. Nonenhanced, static, and dynamic contrast-enhanced MR imaging was performed in 102 adult patients with an orbital mass. Diagnosis was based on histologic findings. MR imaging features of benign and malignant orbital lesions were evaluated correlated with histological findings. Multivariate logistic regression analysis was employed to identify the best combination of MR imaging features that might be predictive of malignancy. Nonenhanced, static, and dynamic enhancement MR imaging was significantly superior to two other models in prediction of malignancy (p < 0.05). Multivariate logistic regression analysis identified that the most discriminating MR imaging features were isointense mass on T2-weighted imaging and a washout-type time-intensity curve for both observers. Nonenhanced, static, and dynamic enhancement MR imaging improved differentiation between benign and malignant orbital masses in adult patients. (orig.)

  3. Modern concepts for basic radiobiological factors characterizing tumor tissue radiosensitivity

    International Nuclear Information System (INIS)

    Gocheva, L.; Sergieva, K.

    2002-01-01

    Traditionally radiotherapy is prescribed at doses consistent with the expected therapeutic response and tolerance of tumor and normal tissues without consideration to individual differences in radiosensitivity. However, the basic radiobiological knowledge and clinical experience along this line point to significant variations in the observed therapeutic results. It has been established that cells and tissues under experimental and clinical conditions manifest a wide spectrum of individual radiosensitivity. The aim of this survey is to outline the current concepts for the basic radiobiological factors influencing tumor radiosensitivity. A thorough discussion is done of the essence, mechanisms of action, methods of determination and measurement, and effect on the prognosis in patients with malignant diseases of a number of radiobiological factors, such as: tumor-cell proliferation, apoptosis, tumor hypoxia and neovascularization. Although the knowledge of the mechanisms of radiosensitivity is constantly expanding, its clinical implementation is still rather limited. The true role of radiosensitivity in predicting the therapeutic response should be more accurately defined. (authors)

  4. Unusual intraconal localization of orbital giant cell angiofibroma.

    Science.gov (United States)

    Ekin, Meryem Altin; Ugurlu, Seyda Karadeniz; Cakalagaoglu, Fulya

    2018-01-01

    Giant cell angiofibroma (GCA) is a recently reported rare soft-tissue tumor that can develop in various sites including orbit. Orbital GCAs were mainly located in the eyelid or extraconal regions such as lacrimal gland and conjunctiva. We report an atypical case of a GCA arising in the intraconal area of the orbit in a 65-year-old male patient. The tumor was excised in total by lateral orbitotomy. Histological and immunohistochemical features were consistent with the diagnosis of GCA. No recurrence was observed during the follow-up of over 2 years. GCA is a rare tumor that should be considered in the differential diagnosis of intraconal orbital tumors. Complete surgical removal is the current optimal treatment option.

  5. Postenucleation orbits in retinoblastoma: treatment with 125I brachytherapy

    International Nuclear Information System (INIS)

    Stannard, Clare; Sealy, Ross; Hering, Egbert; Hough, Jan; Knowles, Ruth; Lecuona, Karin; Reddi, V. Bala

    2002-01-01

    Purpose: Children with retinoblastoma that extends into or through the choroid, sclera, or optic nerve are at risk of developing orbital disease, as well as metastases. Previously, these enucleated orbits were treated with external beam radiotherapy in addition to chemotherapy. 125 I brachytherapy for tumors in and around the eye was pioneered by Sealy in Cape Town, South Africa, in 1974. In 1983, he developed a technique to irradiate the contents of the orbit while limiting the dose to the bony orbit and eyelids. Methods and Materials: Six nylon tubes containing 125 I seeds were implanted through the eyelids around the periphery of the orbit. Each contained a metal gutter that screens the outer part of the seeds from the bony orbit. A seventh unscreened tube was placed in the center, and a metal disc with 125 I seeds on its posterior surface was secured beneath the eyelids. Between 1983 and 2000, 57 orbits were treated in 56 children with retinoblastoma. Thirty-six were treated prophylactically and 21, with tumor at the resection line of the nerve, extrascleral tumor, or metastases, were treated therapeutically. They received a median dose of 34 Gy in 70 h; 30 also received chemotherapy. Children with tumor at the resection line of the nerve also received treatment to the craniospinal axis. Results: The median follow-up of the 35 patients treated prophylactically was 35 months (range 0-187). Seven patients died, 6 of metastases, at a median of 10 months (range 4-29) after the implant. Eight of the 13 patients with microscopic extraocular tumor survived a median of 29 months (range 5-156). None of the 8 patients presenting with orbital tumor or metastases survived. No orbital recurrences developed in any of the patients. Cosmesis was considerably improved compared with previous forms of irradiation. Conclusion: Orbital brachytherapy is an effective method of irradiating the orbit to prevent recurrent tumor, the treatment time is short, and the cosmesis is much more

  6. Orbital Hub: a concept for human spaceflight beyond ISS operations

    Science.gov (United States)

    Jahnke, Stephan S.; Maiwald, Volker; Philpot, Claudia; Quantius, Dominik; Romberg, Oliver; Seboldt, Wolfgang; Vrakking, Vincent; Zeidler, Conrad

    2018-04-01

    The International Space Station (ISS) is the greatest endeavour in low-Earth orbit since the beginning of the space age and the culmination of human outposts like Skylab and Mir. While a clear schedule has yet to be drafted, it is expected that ISS will cease operation in the 2020s. What could be the layout for a human outpost in LEO with lessons learnt from ISS? What are the use cases and applications of such an outpost in the future? The System Analysis Space Segment group of the German Aerospace Center investigated these and other questions and developed the Orbital Hub concept. In this paper an overview is presented of how the overall concept has been derived and its properties and layouts are described. Starting with a workshop involving the science community, the scientific requirements have been derived and Strawman payloads have been defined for use in further design activities. These design activities focused on Concurrent Engineering studies, where besides DLR employees participants from the industry and astronauts were involved. The result is an expandable concept that is composed of two main parts, the Base Platform, home for a permanent crew of up to three astronauts, and the Free Flyer, an uncrewed autonomous research platform. This modular approach provides one major advantage: the decoupling of the habitat and payload leading to increased quality of the micro-gravity environment. The former provides an environment for human physiology experiments, while the latter allows science without the perturbations caused by a crew, e.g. material experiments or Earth observation. The Free Flyer is designed to operate for up to 3 months on its own, but can dock with the space station for maintenance and experiment servicing. It also has a hybrid propulsion system, chemical and electrical, for different applications. The hub's design allows launch with just three launches, as the total mass of all the hub parts is about 60,000 kg. The main focus of the design is

  7. MR imaging of orbital disease

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Yasuyuki; Sato, Ryuiti; Sakamoto, Yuji; Kojima, Ryutaro; Takahashi, Mutsumasa; Maruoka, Syouko; Okamura, Ryoichi; Oguni, Tatsuro.

    1989-05-01

    Sixty five cases with orbital and ocular lesions were evaluated by MRI in comparison with high resolution CT. MRI was performed with spin echo techniques (short TR/TE and long TR/TE) using a 0.22 tesla resistive unit (Toshiba MRT-22A) or a 1.5 tesla superconductive unit (Siemens Magnetom). MRI was superior to CT in (1) detecting ocular lesions and vitreous changes, (2) differentiating a tumor from the adjacent extraocular muscles and optic nerves, (3) identifying the lesion in the orbital apex and demonstrating the posterior extent of the tumor and (4) detecting the abnormal flow in the orbital vascular structures. Although some tumors had specific signal intensities including hemangioma, menigioma, and pseudotumor, majority of tumors revealed non-sepcific signal intensities. CT was superior to MRI in detection for small and calcified lesions as well as visualization of bone details. (author).

  8. Unusual intraconal localization of orbital giant cell angiofibroma

    Directory of Open Access Journals (Sweden)

    Meryem Altin Ekin

    2018-01-01

    Full Text Available Giant cell angiofibroma (GCA is a recently reported rare soft-tissue tumor that can develop in various sites including orbit. Orbital GCAs were mainly located in the eyelid or extraconal regions such as lacrimal gland and conjunctiva. We report an atypical case of a GCA arising in the intraconal area of the orbit in a 65-year-old male patient. The tumor was excised in total by lateral orbitotomy. Histological and immunohistochemical features were consistent with the diagnosis of GCA. No recurrence was observed during the follow-up of over 2 years. GCA is a rare tumor that should be considered in the differential diagnosis of intraconal orbital tumors. Complete surgical removal is the current optimal treatment option.

  9. Parameningeal rhabdomyosarcoma (including the orbit): results of orbital irradiation

    International Nuclear Information System (INIS)

    Jereb, B.; Haik, B.G.; Ong, R.; Ghavimi, F.

    1985-01-01

    Twenty-three patients with parameningeal (including orbital rhabdomyosarcoma (RMS)) were treated at Memorial Sloan-Kettering Cancer Center (MSKCC) between July 1971 and January 1983. Twenty were children with a mean age of 6 and 3 were adults. In 6 patients, the primary tumor was from the orbit, whereas the remaining 17 had other parameningeal primary sites. The tumors were in a very progressive local stage, with extensive destruction of the facial bones in 19 patients. Eight patients were treated with T2 chemotherapy protocol and 15 received T6. Seven patients received 5,000 to 7,200 rad delivered to the primary tumor in 11-16 weeks, 15 patients received between 4,500 to 5,000 rad in 4-7 weeks, and 1 patient received 3,000 rad in 3 weeks for residual microscopic disease following surgery. Two patients were treated with radiation to the whole brain; no patients received radiation of the whole central nervous axis (CNA). Fifteen of the 23 patients (65%) are alive and well with a medical follow-up time of 5 years. Two patients died of therapeutic complications and six died of tumor spread. In five patients, involvement of the central nervous system (CNS) was the cause of death. The prognosis of orbital RMS with parameningeal involvement is no better than in other tumors of parameningeal sites. In those patients who had impaired vision because of optic nerve damage prior to treatment, the vision did not improve following treatment. There was no impaired vision seen due to radiation damage of eye structures except in the lens

  10. Eye and orbital cavity

    International Nuclear Information System (INIS)

    Panfilova, G.V.; Koval', G.Yu.

    1984-01-01

    Radioanatomy of eyes and orbit is described. Diseases of the orbit (developmental anomalies, inflammatory diseases, lacrimal apparatus deseases, toxoplasmosis, tumors and cysts et al.), methods of foreign body localization in the eye are considered. Roentgenograms of the orbit and calculation table for foreign body localization in spherical eyes of dissimilar diameter are presented

  11. Primary Orbital Chondromyxoid Fibroma: A Rare Case.

    Science.gov (United States)

    Mullen, Martin G; Somogyi, Marie; Maxwell, Sean P; Prabhu, Vikram; Yoo, David K

    A 56-year-old male with history of chronic sinusitis was found to have a 3 cm left orbital lesion on CT. Subsequent MRI demonstrated a multilobulated enhancing soft tissue lesion at the superotemporal region of the left orbit. Initial biopsy was reported as a low-grade sarcoma. On further evaluation, a consensus was made that the lesion was likely a benign mixed mesenchymal type tumor but should nonetheless be surgically removed. Left lateral orbitotomy was performed which revealed a tumor originating in the lateral orbital bone with segments eroding through the wall of the orbit. Intraoperative frozen sections revealed myoepitheliod tissue with locally aggressive features and the tumor was completely removed. The final histopathologic analysis of the tissue was consistent with a chondromyxoid fibroma. Chondomyxoid fibroma is a rare entity in the orbital bones and is more commonly seen in long bones.

  12. Technetium tc 99m-labeled red blood cells in the preoperative diagnosis of cavernous hemangioma and other vascular orbital tumors.

    Science.gov (United States)

    Polito, Ennio; Burroni, Luca; Pichierri, Patrizia; Loffredo, Antonio; Vattimo, Angelo G

    2005-12-01

    To evaluate technetium Tc 99m (99mTc) red blood cell scintigraphy as a diagnostic tool for orbital cavernous hemangioma and to differentiate between orbital masses on the basis of their vascularization. We performed 99mTc red blood cell scintigraphy on 23 patients (8 female and 15 male; mean age, 47 years) affected by an orbital mass previously revealed with computed tomography (CT) and magnetic resonance imaging (MRI) and suggesting cavernous hemangioma. In our diagnosis, we considered the orbital increase delayed uptake with the typical scintigraphic pattern known as perfusion blood pool mismatch. The patients underwent biopsy or surgical treatment with transconjunctival cryosurgical extraction when possible. Single-photon emission tomography (SPET) showed intense focal uptake in the orbit corresponding to radiologic findings in 11 patients who underwent surgical treatment and pathologic evaluation (9 cavernous hemangiomas, 1 hemangiopericytoma, and 1 lymphangioma). Clinical or histologic examination of the remaining 22 patients revealed the presence of 5 lymphoid pseudotumors, 2 lymphomas, 2 pleomorphic adenomas of the lacrimal gland, 1 astrocytoma, 1 ophthalmic vein thrombosis, and 1 orbital varix. The confirmation of the preoperative diagnosis by 99mTc red blood cell scintigraphy shows that this technique is a reliable tool for differentiating cavernous hemangiomas from other orbital masses (sensitivity, 100%; specificity, 86%) when ultrasound, CT, and MRI are not diagnostic. Unfortunately, 99mTc red blood cell scintigraphy results were positive in 1 patient with hemangiopericytoma and 1 patient with lymphangioma, which showed increased uptake in the lesion on SPET images because of the vascular nature of these tumors. Therefore, in these cases, the SPET images have to be integrated with data regarding clinical preoperative evaluation and CT scans or MRI studies. On the basis of our study, a complete diagnostic picture, CT scans or MRI studies, and

  13. The Science Operations Concept for the ExoMars 2016 Trace Gas Orbiter

    Science.gov (United States)

    Frew, D.

    2014-04-01

    The ExoMars 2016 Science Operations Centre (SOC) based at the European Space Astronomy Centre is responsible for coordinating the science planning activities for the Trace Gas Orbiter. Science planning will involve all members of the ExoMars 2016 science ground segment (SGS), namely the SOC at ESAC, the Russian SOC at IKI, the orbiter instrument teams and the science management of the 2016 mission represented by the science working team (SWT) that is chaired by the project scientist. The science operations concept for the mission builds on the legacy inherited from previous ESA planetary missions, in particular from Mars Express for the core plan validation aspects and from the Smart-1 lunar mission for the opportunity analysis and longterm planning approach. Further concept drivers have been derived from the ExoMars 2016 mission profile in the areas of orbit predictability, instrument design and the usage of TGO as a relay for surface assets including the ExoMars 2018 rover. This paper will give an over view of the entire uplink planning process as it is conducted over 3 distinct planning cycles. The Long Term Plan (LTP) establishes the baseline science plan and demonstrates the operational feasibility of meeting the mission science goals formulated by the science working team (SWT) at science management level. The LTP has a planning horizon of 6 months. Each month of the baseline science plan is refined with the instrument teams within the Medium Term Plan (MTP) to converge on a frozen attitude request and resource envelopes for all of the observations in the plan. During the Short Term Planning cycle the SOC will iterate with the teams to finalise the commanding for all of the observations in the plan for the coming week. The description of the uplink planning process will focus on two key areas that are common to all of the planning cycles mentioned above: • Science Plan Abstraction: Interacting with the science plan at the appropriate level of abstraction to

  14. [Orbital inflammation].

    Science.gov (United States)

    Mouriaux, F; Coffin-Pichonnet, S; Robert, P-Y; Abad, S; Martin-Silva, N

    2014-12-01

    Orbital inflammation is a generic term encompassing inflammatory pathologies affecting all structures within the orbit : anterior (involvement up to the posterior aspect of the globe), diffuse (involvement of intra- and/or extraconal fat), apical (involvement of the posterior orbit), myositis (involvement of only the extraocular muscles), dacryoadenitis (involvement of the lacrimal gland). We distinguish between specific inflammation and non-specific inflammation, commonly referred to as idiopathic inflammation. Specific orbital inflammation corresponds to a secondary localization of a "generalized" disease (systemic or auto-immune). Idiopathic orbital inflammation corresponds to uniquely orbital inflammation without generalized disease, and thus an unknown etiology. At the top of the differential diagnosis for specific or idiopathic orbital inflammation are malignant tumors, represented most commonly in the adult by lympho-proliferative syndromes and metastases. Treatment of specific orbital inflammation begins with treatment of the underlying disease. For idiopathic orbital inflammation, treatment (most often corticosteroids) is indicated above all in cases of visual loss due to optic neuropathy, in the presence of pain or oculomotor palsy. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  15. Primary primitive neuroectodermal tumor of the orbit

    Directory of Open Access Journals (Sweden)

    Das Dipankar

    2009-01-01

    Full Text Available Primitive neuroectodermal tumor (PNET is a small round cell malignant tumor of neuroectodermal origin. Most of the PNETs occur in the central nervous system (CNS. PNETs recognized outside of CNS are diagnosed as peripheral PNET (pPNET. This tumor which expresses MIC-2 gene (CD99 seems to be least aggressive after complete tumor resection. We describe a rare case of PNET in a young girl.

  16. High-resolution MRI using orbit surface coils for the evaluation of metastatic risk factors in 143 children with retinoblastoma. Part 2: new vs. old imaging concept

    Energy Technology Data Exchange (ETDEWEB)

    Sirin, Selma; Schlamann, Marc; Schweiger, Bernd; Goericke, Sophia L. [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Metz, Klaus A. [University Hospital Essen, Department of Pathology and Neuropathology, Essen (Germany); Bornfeld, Norbert; Holdt, Markus [University Hospital Essen, Department of Ophthalmology, Essen (Germany); Temming, Petra; Schuendeln, Michael M. [University Hospital Essen, Department of Pediatric Hematology and Oncology, Essen (Germany)

    2015-08-15

    High-resolution magnetic resonance imaging (MRI) is recommended for the evaluation of metastatic risk factors in children with retinoblastoma according to recent guidelines. The aim of this study was to compare diagnostic accuracy of a new imaging concept with two orbit surface coils to that of an old imaging concept with one orbit surface coil. One hundred forty-three patients (148 eyes, 64 girls, 79 boys) underwent high-resolution MRI on 1.5 T scanners using orbit surface coils. The old imaging concept (one orbit surface coil focusing on the (most) effected eye additionally to the standard head coil) was used in 100 patients/103 eye; the new imaging concept (two orbit surface coils (each focusing on one eye) additionally to the standard head coil) in 43 patients/45 eyes. Image analysis was performed by two neuroradiologists in consensus. Histopathology served as gold standard. Detection rate for choroidal invasion was higher for the new compared to that for the old imaging concept (sensitivity/specificity 87.5/94.6 % vs. 57.1/96.1 % for choroidal invasion and 100/97.5 % vs. 58.3/97.7 % for massive choroidal invasion, respectively). Sensitivity and specificity for the detection of postlaminar optic nerve infiltration, peribulbar fat, and scleral invasion were comparable in both imaging concepts; however positive predictive value was higher in the new imaging concept (new vs. old imaging concept: 60 vs. 31.6 % for postlaminar and deep postlaminar optic nerve infiltration, respectively, and 100 vs. 66.7 % for scleral invasion). The new imaging concept shows a trend towards improving the accuracy of detecting metastatic risk factors in children with retinoblastoma and is therefore recommended for pretherapeutic imaging and follow-up. (orig.)

  17. High-resolution MRI using orbit surface coils for the evaluation of metastatic risk factors in 143 children with retinoblastoma. Part 2: new vs. old imaging concept

    International Nuclear Information System (INIS)

    Sirin, Selma; Schlamann, Marc; Schweiger, Bernd; Goericke, Sophia L.; Metz, Klaus A.; Bornfeld, Norbert; Holdt, Markus; Temming, Petra; Schuendeln, Michael M.

    2015-01-01

    High-resolution magnetic resonance imaging (MRI) is recommended for the evaluation of metastatic risk factors in children with retinoblastoma according to recent guidelines. The aim of this study was to compare diagnostic accuracy of a new imaging concept with two orbit surface coils to that of an old imaging concept with one orbit surface coil. One hundred forty-three patients (148 eyes, 64 girls, 79 boys) underwent high-resolution MRI on 1.5 T scanners using orbit surface coils. The old imaging concept (one orbit surface coil focusing on the (most) effected eye additionally to the standard head coil) was used in 100 patients/103 eye; the new imaging concept (two orbit surface coils (each focusing on one eye) additionally to the standard head coil) in 43 patients/45 eyes. Image analysis was performed by two neuroradiologists in consensus. Histopathology served as gold standard. Detection rate for choroidal invasion was higher for the new compared to that for the old imaging concept (sensitivity/specificity 87.5/94.6 % vs. 57.1/96.1 % for choroidal invasion and 100/97.5 % vs. 58.3/97.7 % for massive choroidal invasion, respectively). Sensitivity and specificity for the detection of postlaminar optic nerve infiltration, peribulbar fat, and scleral invasion were comparable in both imaging concepts; however positive predictive value was higher in the new imaging concept (new vs. old imaging concept: 60 vs. 31.6 % for postlaminar and deep postlaminar optic nerve infiltration, respectively, and 100 vs. 66.7 % for scleral invasion). The new imaging concept shows a trend towards improving the accuracy of detecting metastatic risk factors in children with retinoblastoma and is therefore recommended for pretherapeutic imaging and follow-up. (orig.)

  18. The orbital and sinonasal hemangiopericytoma, 2 case reports:

    Directory of Open Access Journals (Sweden)

    Maryam Maghbol

    2016-03-01

    Full Text Available Background & objective: Hemangiopericytoma is an uncommon vascular tumor derived from the pericytes of Zimmermann. . The most common location of the tumor is pelvic retroperitoneum and musculoskeletal system of the lower extremities. It is rarely seen in the head and neck area. In addition, only 0.8% to 3% of all orbital tumors and less than 5 % of primary sinonasal tumors are primary hemangiopericytoma, which demonstrates that the orbital and sinonasal cavities are rare locations for this tumor. Case: 2 cases of primary orbital and sinonasal hemangiopericytoma that were successfully treated through surgery were reported. Conclusion: Hemangiopericytoma is an uncommon vascular tumor which has a potentially malignant behavior. Histopathologic features alone do not predict the biologic behavior of the tumor but the increased cellularity, necrosis, hemorrhage and more than 4 mitotic figures per 10 high power field, may elicit a diagnosis of malignant hemangiopericytoma . The local recurrence and the distant metastasis might also occur with an incomplete excision.  The lung, bone and liver are the most common sites of distant metastasis. Thus, the long-term follow-up is recommended after the surgical removal of the tumor.

  19. Orbital express capture system: concept to reality

    Science.gov (United States)

    Stamm, Shane; Motaghedi, Pejmun

    2004-08-01

    The development of autonomous servicing of on-orbit spacecraft has been a sought after objective for many years. A critical component of on-orbit servicing involves the ability to successfully capture, institute mate, and perform electrical and fluid transfers autonomously. As part of a Small Business Innovation Research (SBIR) grant, Starsys Research Corporation (SRC) began developing such a system. Phase I of the grant started in 1999, with initial work focusing on simultaneously defining the parameters associated with successful docking while designing to those parameters. Despite the challenge of working without specific requirements, SRC completed development of a prototype design in 2000. Throughout the following year, testing was conducted on the prototype to characterize its performance. Having successfully completed work on the prototype, SRC began a Phase II SBIR effort in mid-2001. The focus of the second phase was a commercialization effort designed to augment the prototype model into a more flight-like design. The technical requirements, however, still needed clear definition for the design to progress. The advent of the Orbital Express (OE) program provided much of that definition. While still in the proposal stages of the OE program, SRC began tailoring prototype redesign efforts to the OE program requirements. A primary challenge involved striking a balance between addressing the technical requirements of OE while designing within the scope of the SBIR. Upon award of the OE contract, the Phase II SBIR design has been fully developed. This new design, designated the Mechanical Docking System (MDS), successfully incorporated many of the requirements of the OE program. SRC is now completing dynamic testing on the MDS hardware, with a parallel effort of developing a flight design for OE. As testing on the MDS progresses, the design path that was once common to both SBIR effort and the OE program begins to diverge. The MDS will complete the scope of the

  20. Small Aerostationary Telecommunications Orbiter Concept for Mars in the 2020s

    Science.gov (United States)

    Lock, Robert E.; Edwards, Charles D., Jr.; Nicholas, Austin; Woolley, Ryan; Bell, David J.

    2016-01-01

    Current Mars science orbiters carry UHF proximity payloads to provide limited access and data services to landers and rovers on Mars surface. In the era of human spaceflight to Mars, very high rate and reliable relay services will be needed to serve a large number of supporting vehicles, habitats, and orbiters, as well as astronaut EVAs. These will likely be provided by a robust network of orbiting assets in very high orbits, such as areostationary orbits. In the decade leading to that era, telecommunications orbits can be operated at areostationary orbit that can support a significant population of robotic precursor missions and build the network capabilities needed for the human spaceflight era. Telecommunications orbiters of modest size and cost, delivered by Solar Electric Propulsion to areostationary orbit, can provide continuous access at very high data rates to users on the surface and in Mars orbit.In the era of human spaceflight to Mars very high rate andreliable relay services will be needed to serve a largenumber of supporting vehicles, habitats, and orbiters, aswell as astronaut EVAs. These could be provided by arobust network of orbiting assets in very high orbits. In thedecade leading to that era, telecommunications orbiterscould be operated at areostationary orbit that could support asignificant population of robotic precursor missions andbuild the network capabilities needed for the humanspaceflight era. These orbiters could demonstrate thecapabilities and services needed for the future but withoutthe high bandwidth and high reliability requirements neededfor human spaceflight.Telecommunications orbiters of modest size and cost,delivered by Solar Electric Propulsion to areostationaryorbit, could provide continuous access at very high datarates to users on the surface and in Mars orbit. Twoexamples highlighting the wide variety of orbiter deliveryand configuration options were shown that could providehigh-performance service to users.

  1. Pathology of orbital bones. The XXXII Edward Jackson Memorial Lecture.

    Science.gov (United States)

    Blodi, F C

    1976-01-01

    The orbital bones may show nearly all the pathologic changes observed in the skull and in the face. The congenital anomalies in this area are numerous and involve various forms of craniostenoses. Among the benign osseous tumors the osteoma is most frequently encountered in the orbit. Fibrous dysplasia is a tumefaction of indeterminate behavior that often involves the orbit. Osteosarcoma or other malignant neoplasms are rarely seen in this area. Eosinophilic granuloma and Hand-Schüller-Christian disease are tumor-like lesions that may involve the orbit.

  2. Space station orbit maintenance

    Science.gov (United States)

    Kaplan, D. I.; Jones, R. M.

    1983-01-01

    The orbit maintenance problem is examined for two low-earth-orbiting space station concepts - the large, manned Space Operations Center (SOC) and the smaller, unmanned Science and Applications Space Platform (SASP). Atmospheric drag forces are calculated, and circular orbit altitudes are selected to assure a 90 day decay period in the event of catastrophic propulsion system failure. Several thrusting strategies for orbit maintenance are discussed. Various chemical and electric propulsion systems for orbit maintenance are compared on the basis of propellant resupply requirements, power requirements, Shuttle launch costs, and technology readiness.

  3. Diagnostic Approaches to Metastatic Hepatocellular Carcinoma of the Orbit.

    Science.gov (United States)

    Geske, Michael J; Bloomer, Michele M; Kersten, Robert C; Vagefi, M Reza

    Orbital metastasis of hepatocellular carcinoma is exceedingly rare and caries a grave prognosis. Three cases of metastatic orbital hepatocellular carcinoma in which the primary tumor was initially unknown and the diagnostic challenges encountered are presented. With hepatocellular carcinoma, open biopsy and palliative tumor debulking has an increased bleeding risk due to the highly vascular nature of the tumor and coagulopathy associated with chronic liver disease. As an alternative, fine needle aspiration biopsy should be considered for hepatocellular carcinoma with a readily accessible mass and the availability of an experienced cytopathologist.

  4. Diffusion weighted imaging for differentiating benign from malignant orbital tumors: Diagnostic performance of the apparent diffusion coefficient based on region of interest selection method

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xiao Quan; Hu, Hao Hu; Su, Guo Yi; Liu, Hu; Shi, Hai Bin; Wu, Fei Yun [First Affiliated Hospital of Nanjing Medical University, Nanjing (China)

    2016-09-15

    To evaluate the differences in the apparent diffusion coefficient (ADC) measurements based on three different region of interest (ROI) selection methods, and compare their diagnostic performance in differentiating benign from malignant orbital tumors. Diffusion-weighted imaging data of sixty-four patients with orbital tumors (33 benign and 31 malignant) were retrospectively analyzed. Two readers independently measured the ADC values using three different ROIs selection methods including whole-tumor (WT), single-slice (SS), and reader-defined small sample (RDSS). The differences of ADC values (ADC-ROI{sub WT}, ADC-ROI{sub SS}, and ADC-ROI{sub RDSS}) between benign and malignant group were compared using unpaired t test. Receiver operating characteristic curve was used to determine and compare their diagnostic ability. The ADC measurement time was compared using ANOVA analysis and the measurement reproducibility was assessed using Bland-Altman method and intra-class correlation coefficient (ICC). Malignant group showed significantly lower ADC-ROI{sub WT}, ADC-ROI{sub SS}, and ADC-ROI{sub RDSS} than benign group (all p < 0.05). The areas under the curve showed no significant difference when using ADC-ROI{sub WT}, ADC-ROI{sub SS}, and ADC-ROI{sub RDSS} as differentiating index, respectively (all p > 0.05). The ROI{sub SS} and ROI{sub RDSS} required comparable measurement time (p > 0.05), while significantly shorter than ROI{sub WT} (p < 0.05). The ROI{sub SS} showed the best reproducibility (mean difference ± limits of agreement between two readers were 0.022 [-0.080–0.123] × 10{sup -3} mm{sup 2}/s; ICC, 0.997) among three ROI method. Apparent diffusion coefficient values based on the three different ROI selection methods can help to differentiate benign from malignant orbital tumors. The results of measurement time, reproducibility and diagnostic ability suggest that the ROI{sub SS} method are potentially useful for clinical practice.

  5. Skull base tumors: a comprehensive review of transfacial swing osteotomy approaches.

    Science.gov (United States)

    Moreira-Gonzalez, Andrea; Pieper, Daniel R; Cambra, Jorge Balaguer; Simman, Richard; Jackson, Ian T

    2005-03-01

    Numerous techniques have been proposed for the resection of skull base tumors, each one unique with regard to the region exposed and degree of technical complexity. This study describes the use of transfacial swing osteotomies in accessing lesions located at various levels of the cranial base. Eight patients who underwent transfacial swings for exposure and resection of cranial base lesions between 1996 and 2002 were studied. The mandible was the choice when wide exposure of nasopharyngeal and midline skull base tumors was necessary, especially when they involved the infratemporal fossa. The midfacial swing osteotomy was an option when access to the entire clivus was necessary. An orbital swing approach was used to access large orbital tumors lying inferior to the optic nerve and posterior to the globe, a region that is often difficult to visualize. Gross total tumor excision was possible in all patients. Six patients achieved disease control and two had recurrences. The complications of cerebrospinal fluid leak, infection, hematoma, or cranial nerve damage did not occur. After surgery, some patients experienced temporary symptoms caused by local swelling. The aesthetic result was considered good. Transfacial swing osteotomies provide a wide exposure to tumors that occur in the central skull base area. Excellent knowledge of the detailed anatomy of this region is paramount to the success of this surgery. The team concept is essential; it is built around the craniofacial surgeon and an experienced skull base neurosurgeon.

  6. Quantitative Assessment of Orbital Implant Position--A Proof of Concept.

    Directory of Open Access Journals (Sweden)

    Ruud Schreurs

    Full Text Available In orbital reconstruction, the optimal location of a predefined implant can be planned preoperatively. Surgical results can be assessed intraoperatively or postoperatively. A novel method for quantifying orbital implant position is introduced. The method measures predictability of implant placement: transformation parameters between planned and resulting implant position are quantified.The method was tested on 3 human specimen heads. Computed Tomography scans were acquired at baseline with intact orbits (t0, after creation of the defect (t1 and postoperatively after reconstruction of the defect using a preformed implant (t2. Prior to reconstruction, the optimal implant position was planned on the t0 and t1 scans. Postoperatively, the planned and realized implant position were compared. The t0 and t2 scans were fused using iPlan software and the resulting implant was segmented in the fused t2 scan. An implant reference frame was created (Orbital Implant Positioning Frame; the planned implant was transformed to the reference position using an Iterative Closest Point approach. The segmentation of the resulting implant was also registered on the reference position, yielding rotational (pitch, yaw, roll as well as translational parameters of implant position.Measurement with the Orbital Implant Positioning Frame proved feasible on all three specimen. The positional outcome provided more thorough and accurate insight in resulting implant position than could be gathered from distance measurements alone. Observer-related errors were abolished from the process, since the method is largely automatic.A novel method of quantifying surgical outcome in orbital reconstructive surgery was presented. The presented Orbital Implant Positioning Frame assessed all parameters involved in implant displacement. The method proved to be viable on three human specimen heads. Clinically, the method could provide direct feedback intraoperatively and could improve

  7. Ophthalmic Artery Embolization as Pretreatment of Orbital Exenteration for Conjunctival Squamous Cell Carcinoma

    International Nuclear Information System (INIS)

    Matsuo, Toshihiko; Ohara, Nobuya; Namba, Yuzaburo; Koshima, Isao; Ida, Kentaro; Kanazawa, Susumu

    2009-01-01

    The aim of this study is to describe the effect of transarterial embolization from the ophthalmic artery as a pretreatment for orbital exenteration. A 75-year-old Chinese man with a 7-year history of gradual increase of the left eye swelling showed a massive conjunctival tumor growing outwardly from the interpalpebral fissure and had no light perception in the left eye. Magnetic resonance imaging showed orbital invasion of the tumor around the left eyeglobe. The initial surgery for the planned orbital exenteration was discontinued after skin incision around the orbital margin due to massive hemorrhage. The patient underwent transarterial embolization with gelatin sponge (Spongel) of the feeding arteries from the left ophthalmic artery and, the next day, had orbital exenteration with well-controllable bleeding and reconstruction with free vascularized anterolateral thigh cutaneous flap transfer. Pathologically, well-differentiated squamous cell carcinoma proliferated in exophytic, papillary, and nested fashions, arising from the bulbar conjunctiva. Tumor cells were also found in the conjunctival stroma around the vessels. The sclera at the equator had a perforated site with tumor cell invasion, but no intraocular invasion was found. Hematoxylin-positive gelatin sponges were found inside the orbital vessels and large choroidal vessels. In conclusion, transarterial embolization of feeding arteries arising from the ophthalmic artery is a useful pretreatment to control bleeding at orbital exenteration for malignancy.

  8. Orbital manifestations in patients with acquired immunodeficiency syndrome.

    Science.gov (United States)

    Sodhi, Punita Kumari

    2014-01-01

    The orbital manifestations of acquired immunodeficiency syndrome(AIDS) are uncommon. To provide a review of orbital manifestations of AIDS, the predisposing factors, investigations, treatment and outcome. Meticulous and systematic literature search of Pubmed to identify manuscripts describing orbital manifestations of AIDS was done and the articles were reviewed.The keywords used in the search were “orbit and AIDS”, “HIV positive and orbit”,“orbit manifestations in AIDS”, “orbital disease and AIDS” and “orbital infections and AIDS”. The orbital involvement in AIDS may present with opportunistic infections from organisms like fungi, viruses, bacteria and protozoa or with malignancies like Kaposi’s sarcoma, squamous cell carcinoma, smooth muscle cell tumors and lymphoma.The predisposing factors for orbital involvement in AIDS are low CD4+ cell count and the immunosuppressive states like diabetes, diabetic ketoacidosis, intravenous drug abuse and neutropenia. A patient may present with fever, headache, nausea, vomiting,decreased vision, ocular pain, and, in cases of mass formation, there is periorbital swelling, axial proptosis, globe displacement and swollen optic disc. Radiologically,mass formation, orbital bony destruction, and spread of disease to contiguous structures including the central nervous system may be seen. The medical management includes therapy for infection and HIV-1 protease inhibitors (highly active antiretroviral therapy)to suppress HIV-1 replication. For tumors, radical surgery including debulking followed by postoperative radiotherapy is generally needed. Orbital involvements with AIDS in any form, infective or malignancy, causes significant morbidity and mortality and should be diagnosed and managed as early as possible.

  9. Imaging of childhood inflammatory myofibroblastic tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oguz, Berna; Ozcan, Hatice Nursun; Omay, Burak; Ozgen, Burce; Haliloglu, Mithat [Division of Pediatric Radiology, Hacettepe University Faculty of Medicine, Department of Radiology, Altindag / Sihhiye, Ankara (Turkey)

    2015-10-15

    Inflammatory myofibroblastic tumor is a rare benign neoplasm and most commonly involves the lung but occurs in extrapulmonary locations. To present imaging findings in inflammatory myofibroblastic tumors in children based on a single-centre experience. We retrospectively reviewed CT and MRI findings of children diagnosed with inflammatory myofibroblastic tumor in a single institution. We identified 15 children (range: 1-17 years) with inflammatory myofibroblastic tumor. The tumor was localized to the lung (n = 5), mediastinum (n = 3), trachea (n = 1), bronchus (n = 1), abdomen (n = 2) and orbit (n = 3). All the extraorbital tumors were solid masses with homogeneous or heterogeneous enhancement. Four lung tumors and one posterior mediastinal tumor contained calcification. Local recurrence following surgical removal occurred in two children with invasion of the esophagus and of the left atrium in one. Localized masses were seen in all children with orbital tumour. Two of these had episcleritis and perineuritis; one had episcleritis, tendonitis, perineuritis, myositis and dacryoadenitis. The locations and imaging features of inflammatory myofibroblastic tumors are variable. (orig.)

  10. Weights assessment for orbit-on-demand vehicles

    Science.gov (United States)

    Macconochie, I. O.; Martin, J. A.; Breiner, C. A.; Cerro, J. A.

    1985-01-01

    Future manned, reusable earth-to-orbit vehicles may be required to reach orbit within hours or even minutes of a mission decision. A study has been conducted to consider vehicles with such a capability. In the initial phase of the study, 11 vehicles were sized for deployment of 5000 lbs to a polar orbit. From this matrix, two of the most promising concepts were resized for a modified mission and payload. A key feature of the study was the use of consistent mass estimating techniques for a broad range of concepts, allowing direct comparisons of sizes and weights.

  11. Illustrating Concepts in Physical Organic Chemistry with 3D Printed Orbitals

    Science.gov (United States)

    Robertson, Michael J.; Jorgensen, William L.

    2015-01-01

    Orbital theory provides a powerful tool for rationalizing and understanding many phenomena in chemistry. In most introductory chemistry courses, students are introduced to atomic and molecular orbitals in the form of two-dimensional drawings. In this work, we describe a general method for producing 3D printing files of orbital models that can be…

  12. Intraosseous hemangioma of the orbit.

    Science.gov (United States)

    Choi, June Seok; Bae, Yong Chan; Kang, Gyu Bin; Choi, Kyung-Un

    2018-03-01

    Intraosseous hemangioma is an extremely rare tumor that accounts for 1% or fewer of all osseous tumors. The most common sites of its occurrence are the vertebral column and calvaria. Occurrence in a facial bone is very rare. The authors aim to report a case of the surgical treatment of intraosseous hemangioma occurring in the periorbital region, which is a very rare site of occurrence and to introduce our own experiences with the diagnosis and treatment of this condition along with a literature review. A 73-year-old male patient visited our hospital with the chief complaint of a mass touching the left orbital rim. A biopsy was performed by applying a direct incision after local anesthesia. Eventually, intraosseous hemangioma was diagnosed histologically. To fully resect the mass, the orbital floor and zygoma were exposed through a subciliary incision under general anesthesia, and then the tumor was completely eliminated. Bony defect was reconstructed by performing a seventh rib bone graft. Follow-up observation has so far been conducted for 10 months after surgery without recurrence or symptoms.

  13. HIAD on ULA (HULA) Orbital Reentry Flight Experiment Concept

    Science.gov (United States)

    Dinonno, J. M.; Cheatwood, F. M.; Hughes, S. J.; Ragab, M. M.; Dillman, R. A.; Bodkin, R. J.; Zumwalt, C. H.; Johnson, R. K.

    2016-01-01

    This paper describes a proposed orbital velocity reentry flight test of a Hypersonic Inflatable Aerodynamic Decelerator (HIAD). The flight test builds upon ground development activities that continue to advance the materials, design, and manufacturing techniques for the inflatable structure and flexible thermal protection system (F-TPS) that comprise the inflatable heat shield. While certain aspects of material and system performance can be assessed using a variety of ground testing capabilities, only orbital velocity energy on a trajectory through the gradient density of the atmosphere can impart the combined aerodynamic and aeroheating design environments in real time. To achieve this at limited cost, the HIAD would be delivered to a spin-stabilized entry trajectory as a secondary payload on the Centaur stage of a United Launch Alliance (ULA) Atlas V launch vehicle. Initial trajectory studies indicate that the combination of launch vehicle capability and achievable reentry vehicle ballistic numbers make this a strategic opportunity for technology development. This 4 to 6 meter diameter scale aeroshell flight, referred to as HIAD on ULA (HULA), would also contribute to ULA asset recovery development. ULA has proposed that a HIAD be utilized as part of the Sensible, Modular, Autonomous Return Technology (SMART) initiative to enable recovery of the Vulcan launch vehicle booster main engines [1], including a Mid-Air Recovery (MAR) to gently return these assets for reuse. Whereas HULA will attain valuable aerothermal and structural response data toward advancing HIAD technology, it may also provide a largest-to-date scaled flight test of the MAR operation, which in turn would allow the examination of a nearly pristine post-entry aeroshell. By utilizing infrared camera imaging, HULA will also attain aft-side thermal response data, enhancing understanding of the aft side aerothermal environment, an area of high uncertainty. The aeroshell inflation will utilize a

  14. Computed tomography of the eye and orbit

    International Nuclear Information System (INIS)

    Hammerschlag, S.B.; Hesselink, J.R.; Weber, A.L.

    1982-01-01

    This book is the product of the evolution of computed tomography (CT) into subspecialization and the need for one source of information for the busy radiologist. The authors have succeeded in providing a readable overview of orbital CT as well as a reference book. The book is divided into seven major catagories of pathology (Neurofibromatosis, Primary Orbital Neoplasms, Secondary and Metastic Tumors of the Orbit, Vascular Disorders, Inflammatory Disease, Occular Lesions, and Trauma) after separate discussions of anatomy and technique

  15. A new kinematical definition of orbital eccentricity

    Directory of Open Access Journals (Sweden)

    Ninković S.

    2009-01-01

    Full Text Available A new concept of orbital eccentricity is given. The dimensionless quantities proposed in the present paper to serve as orbital eccentricities have a kinematical nature. The purpose is to use them in describing the motion for the case of three-dimensional orbits. A comparison done for nearly planar orbits shows that the values of the eccentricities proposed here do not differ significantly from those corresponding to the eccentricities of geometric nature usually applied.

  16. Theory and design methods of special space orbits

    CERN Document Server

    Zhang, Yasheng; Zhou, Haijun

    2017-01-01

    This book focuses on the theory and design of special space orbits. Offering a systematic and detailed introduction to the hovering orbit, spiral cruising orbit, multi-target rendezvous orbit, initiative approaching orbit, responsive orbit and earth pole-sitter orbit, it also discusses the concept, theory, design methods and application of special space orbits, particularly the design and control method based on kinematics and astrodynamics. In addition the book presents the latest research and its application in space missions. It is intended for researchers, engineers and postgraduates, especially those working in the fields of orbit design and control, as well as space-mission planning and research.

  17. Prevention of radiochemotherapy-induced toxicity with amifostine in patients with malignant orbital tumors involving the lacrimal gland: a pilot study

    International Nuclear Information System (INIS)

    Goldblum, David; Ghadjar, Pirus; Curschmann, Juergen; Greiner, Richard; Aebersold, Daniel

    2008-01-01

    To use amifostine concurrently with radiochemotherapy (CT-RT) or radiotherapy (RT) alone in order to prevent dry eye syndrome in patients with malignancies located in the fronto-orbital region. Five patients (2 males, 3 females) with diagnosed malignancies (Non-Hodgkin B-cell Lymphoma, neuroendocrine carcinoma) involving the lacrimal gland, in which either combined CT-RT or local RT were indicated, were prophylactically treated with amifostine (500 mg sc). Single RT fraction dose, total dose and treatment duration were individually adjusted to the patient's need. Acute and late adverse effects were recorded using the RTOG score. Subjective and objective dry eye assessment was performed for the post-treatment control of lacrimal gland function. All patients have completed CT-RT or RT as indicated. The median total duration of RT was 29 days (range, 23 – 39 days) and the median total RT dose was 40 Gy (range, 36 – 60 Gy). Median lacrimal gland exposure was 35.9 Gy (range, 16.8 – 42.6 Gy). Very good partial or complete tumor remission was achieved in all patients. The treatment was well tolerated without major toxic reactions. Post-treatment control did not reveal in any patient either subjective or objective signs of a dry eye syndrome. The addition of amifostine to RT/CT-RT of patients with tumors localized in orbital region was found to be associated with absence of dry eye syndrome

  18. Symmetry orbits and their data-analytic properties

    Directory of Open Access Journals (Sweden)

    Marlos A.G. Viana

    2013-08-01

    Full Text Available The concept of data indexed by finite symmetry orbits is reviewed within the data-analytic framework of symmetry studies. Data decompositions are discussed in terms of canonical projections and Plancherel’s formulas, and interpreted in terms of orbit invariants.

  19. Therapy of brain stem tumors - palliative conception with prospect of curative success

    International Nuclear Information System (INIS)

    Bamberg, M.; Budach, V.; Clar, H.E.; Schmitt, G.

    1984-01-01

    From 1969 to 1981, 23 patients with tumors in the pons region were irradiated at the Department of Radiotherapy of the West German Tumor Center in Essen. The age of the patients ranged from 18 months to 50 years. Fifteen patients (65%) were younger than 18 years, one was 25 years old, and seven were between 40 and 50 years old. In two cases the histologic diagnosis of an astrocytoma I and astrocytoma II could be confirmed by exploratory excision and cyst punction, respectively. Nineteen patients received a shunt system (ventriculoatrial shunt) prior to radiotherapy in order to achieve a pressure reduction. After a follow-up period of 1.5 to 12 years, eleven patients are alive, and twelve patients died from a local recurrence or from progressive tumor growth. The five-year survival rate is 47%. Five of the surviving patients show no or only slight adverse effects on their general condition and are able to attend school or carry out their profession (in Karnofsky: 90 to 100%). Four other patients suffering from marked remaining neurologic symptoms are able to take care of themselves (Karnofsky: 70 to 80%). Two patients need permanent nursing (Karnofsky: 50 to 60%). Because of the local propagation tendency of pons tumors, radiotherapy should be locally restricted to the brain stem and the adjacent brain structures, e.g. cerebellum and proximal neck marrow. The authors recommend target volumes of 55 to 60 Gy, which must be applied within 6 to 8 weeks, taking into account the age of patients. This palliative therapy conception should be applied routinely in the hope of bringing about a curative treatment to this group of patients. (orig.) [de

  20. Kimura's Disease of the Orbit Successfully Treated with Radiotherapy Alone: A Case Report

    Directory of Open Access Journals (Sweden)

    Yoshio Monzen

    2014-03-01

    Full Text Available We performed radiotherapy in a 28-year-old patient with Kimura's disease of the orbit. Irradiation with 21.6 Gy was administered to the tumor bed with a single dose of 1.8 Gy in 5 weekly fractions delivered via a high-energy linear accelerator (6-MV X-ray. Complete remission of the tumor and improvements in the neurological findings were achieved. Neither tumor regrowth nor late complications were detected up to 84 months after radiotherapy. Radiotherapy is an effective treatment for Kimura's disease of the orbit.

  1. Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer.

    Science.gov (United States)

    Karava, Konstantina; Ehrbar, Stefanie; Riesterer, Oliver; Roesch, Johannes; Glatz, Stefan; Klöck, Stephan; Guckenberger, Matthias; Tanadini-Lang, Stephanie

    2017-11-09

    Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for pancreatic tumors with both the internal target volume (ITV) concept and the tumor tracking approach was performed. The two respiratory motion-management techniques were compared in terms of doses to the target volume and organs at risk. Two volumetric-modulated arc therapy (VMAT) treatment plans (5 × 5 Gy) were created for each of the 12 previously treated pancreatic cancer patients, one using the ITV concept and one the tumor tracking approach. To better evaluate the overall dose delivered to the moving tumor volume, 4D dose calculations were performed on four-dimensional computed tomography (4DCT) scans. The resulting planning target volume (PTV) size for each technique was analyzed. Target and OAR dose parameters were reported and analyzed for both 3D and 4D dose calculation. Tumor motion ranged from 1.3 to 11.2 mm. Tracking led to a reduction of PTV size (max. 39.2%) accompanied with significant better tumor coverage (p<0.05, paired Wilcoxon signed rank test) both in 3D and 4D dose calculations and improved organ at risk sparing. Especially for duodenum, stomach and liver, the mean dose was significantly reduced (p<0.05) with tracking for 3D and 4D dose calculations. By using an adaptive tumor tracking approach for respiratory-induced pancreatic motion management, a significant reduction in PTV size can be achieved, which subsequently facilitates treatment planning, and improves organ dose sparing. The dosimetric benefit of tumor tracking is organ and patient-specific.

  2. Low-Cost 3D Printing Orbital Implant Templates in Secondary Orbital Reconstructions.

    Science.gov (United States)

    Callahan, Alison B; Campbell, Ashley A; Petris, Carisa; Kazim, Michael

    Despite its increasing use in craniofacial reconstructions, three-dimensional (3D) printing of customized orbital implants has not been widely adopted. Limitations include the cost of 3D printers able to print in a biocompatible material suitable for implantation in the orbit and the breadth of available implant materials. The authors report the technique of low-cost 3D printing of orbital implant templates used in complex, often secondary, orbital reconstructions. A retrospective case series of 5 orbital reconstructions utilizing a technique of 3D printed orbital implant templates is presented. Each patient's Digital Imaging and Communications in Medicine data were uploaded and processed to create 3D renderings upon which a customized implant was designed and sent electronically to printers open for student use at our affiliated institutions. The mock implants were sterilized and used intraoperatively as a stencil and mold. The final implant material was chosen by the surgeons based on the requirements of the case. Five orbital reconstructions were performed with this technique: 3 tumor reconstructions and 2 orbital fractures. Four of the 5 cases were secondary reconstructions. Molded Medpor Titan (Stryker, Kalamazoo, MI) implants were used in 4 cases and titanium mesh in 1 case. The stenciled and molded implants were adjusted no more than 2 times before anchored in place (mean 1). No case underwent further revision. The technique and cases presented demonstrate 1) the feasibility and accessibility of low-cost, independent use of 3D printing technology to fashion patient-specific implants in orbital reconstructions, 2) the ability to apply this technology to the surgeon's preference of any routinely implantable material, and 3) the utility of this technique in complex, secondary reconstructions.

  3. A novel orbiter mission concept for venus with the EnVision proposal

    Science.gov (United States)

    de Oliveira, Marta R. R.; Gil, Paulo J. S.; Ghail, Richard

    2018-07-01

    In space exploration, planetary orbiter missions are essential to gain insight into planets as a whole, and to help uncover unanswered scientific questions. In particular, the planets closest to the Earth have been a privileged target of the world's leading space agencies. EnVision is a mission proposal designed for Venus and competing for ESA's next launch opportunity with the objective of studying Earth's closest neighbor. The main goal is to study geological and atmospheric processes, namely surface processes, interior dynamics and atmosphere, to determine the reasons behind Venus and Earth's radically different evolution despite the planets' similarities. To achieve these goals, the operational orbit selection is a fundamental element of the mission design process. The design of an orbit around Venus faces specific challenges, such as the impossibility of choosing Sun-synchronous orbits. In this paper, an innovative genetic algorithm optimization was applied to select the optimal orbit based on the parameters with more influence in the mission planning, in particular the mission duration and the coverage of sites of interest on the Venusian surface. The solution obtained is a near-polar circular orbit with an altitude of 259 km that enables the coverage of all priority targets almost two times faster than with the parameters considered before this study.

  4. Orbital exenteration: Institutional review of evolving trends in indications and rehabilitation techniques.

    Science.gov (United States)

    Kiratli, Hayyam; Koç, İrem

    2018-06-01

    To determine the changes in indications for orbital exenteration over 20 years and to assess its impact on patient survival. Evolving techniques of rehabilitation of the orbit in our institution were also evaluated. This was a retrospective review of hospital records of patients who underwent orbital exenteration from 1995 to 2015 in a tertiary care center. Data extracted included primary location of the tumor, preoperative treatments, interval between initial diagnosis and exenteration, status of surgical margins, presence of metastatic disease, and postoperative survival. The types of prosthesis utilized over the years were also reviewed. Cox regression analysis was performed for categorical variables. Kaplan-Meier analysis was used to estimate post-exenteration survival. Over a 20-year period, orbital exenteration was performed on 100 orbits of 100 patients. The mean age was 39.4 years (range: 2 months to 90 years). The most common indications among 98 malignant causes were retinoblastoma, squamous cell carcinoma, basal cell carcinoma, extraocular extension of uveal melanoma, and conjunctival melanoma. Postoperative survival was significantly related to age and tumor location but independent from gender, surgical margin, histopathological diagnosis, previous treatment modality, and preoperative interval. In the whole cohort, 1-year and 5-year survival rates were 97% and 84%, respectively. Exenteration appears to be life-saving in children with orbital extension of retinoblastoma. While patients exenterated for malignant eyelid tumors have the best chance of survival, those with orbital extension of uveal melanoma and adenoid cystic carcinoma of the lacrimal gland have the worst prognosis.

  5. Palliative radiotherapy. Ranking within an interdisciplinary treatment concept in case of advanced tumor disease

    International Nuclear Information System (INIS)

    Seegenschmiedt, M.H.

    1998-01-01

    Many tumor-induced symptoms can be alleviated by suitable irradiation in a direct, effective and sparing manner. The clinical response amounts to 80% and is independent of tumor histology. Careful diagnosis and accurate localisation of the causes of symptoms as well as exact therapy planning and execution are required. Based on individual dose planning harmonising single dosis and total dosis, pin-pointed definition of target areas, and application of modern planning and irradiation techniques, palliative radiotherapy is able to achieve long-term improvement with neglectible side-effects, sometimes within only a few days or weeks. It is a valuable part of a consistant therapy concept that is tailored to the individual needs of a patient, by cooperative action of experts from a variety of medical disciplines, intended to optimize the quality of life of patients, and sometimes may exclude conventional radiotherapy. (orig./CB) [de

  6. Topological imprint for periodic orbits

    International Nuclear Information System (INIS)

    Martín, Jesús San; Moscoso, Ma José; Gómez, A González

    2012-01-01

    The more self-crossing points an orbit has the more complex it is. We introduce the topological imprint to characterize crossing points and focus on the period-doubling cascade. The period-doubling cascade topological imprint determines the topological imprint for orbits in chaotic bands. In addition, there is a closer link between this concept and the braids studied by Lettelier et al (2000 J. Phys. A: Math. Gen. 33 1809–25). (paper)

  7. Radiation treatment of brain tumors: Concepts and strategies

    International Nuclear Information System (INIS)

    Marks, J.E.

    1989-01-01

    Ionizing radiation has demonstrated clinical value for a multitude of CNS tumors. Application of the different physical modalities available has made it possible for the radiotherapist to concentrate the radiation in the region of the tumor with relative sparing of the surrounding normal tissues. Correlation of radiation dose with effect on cranial soft tissues, normal brain, and tumor has shown increasing effect with increasing dose. By using different physical modalities to alter the distribution of radiation dose, it is possible to increase the dose to the tumor and reduce the dose to the normal tissues. Alteration of the volume irradiated and the dose delivered to cranial soft tissues, normal brain, and tumor are strategies that have been effective in improving survival and decreasing complications. The quest for therapeutic gain using hyperbaric oxygen, neutrons, radiation sensitizers, chemotherapeutic agents, and BNCT has met with limited success. Both neoplastic and normal cells are affected simultaneously by all modalities of treatment, including ionizing radiation. Consequently, one is unable to totally depopulate a tumor without irreversibly damaging the normal tissues. In the case of radiation, it is the brain that limits delivery of curative doses, and in the case of chemical additives, it is other organ systems, such as bone marrow, liver, lung, kidneys, and peripheral nerves. Thus, the major obstacle in the treatment of malignant gliomas is our inability to preferentially affect the tumor with the modalities available. Until it is possible to directly target the neoplastic cell without affecting so many of the adjacent normal cells, the quest for therapeutic gain will go unrealized.72 references

  8. Computed tomographic features of orbital lesions

    International Nuclear Information System (INIS)

    Azevedo, C.M. de; Hoch, H.; Azevedo, M. de L.

    1990-01-01

    The purpose of this m anuscript is to present the use of CT in the evaluation of 42 cases of orbital lesions studied at the National Institute of Cancer in an one year and half period. Correlation with clinical and pathological data was performed and the results compared with those of the literature. Four cases of rare lesions are shown: alveolar soft tissue sarcoma, giant cell tumor and hematogenic metastatic deposits of a clear cell sarcoma and epidermoid carcinoma. The value of CT in the evaluation of all orbital masses is emphasized. (author) [pt

  9. Cholesterol granuloma of the orbit: An atypical presentation

    Directory of Open Access Journals (Sweden)

    Syed A R Rizvi

    2014-01-01

    Full Text Available Cholesterol granuloma is a rare, well-defined lesion of the orbit. In the orbit, diploe of the frontal bone is involved almost exclusively. We report an atypical case of cholesterol granuloma involving superomedial quadrant of orbit. A 42-year-old male presented with progressive, painless, proptosis with infero-temporal displacement of left eye. A large mass was felt beneath the bony orbital margin in the superomedial quadrant of the left orbit. Computerized tomography (CT scan revealed an extraconal superomedial, heterogeneous enhancing mass which was isodense with brain and pushing the globe inferolaterally and anteriorly. Excision biopsy of the tumor revealed the typical features of a cholesterol granuloma without any epithelial elements. Cholesterol granuloma of the orbit is a rare entity, but it can be diagnosed and differentiated from other lesions of the superior orbit by its characteristic clinical, radiological and histopathological features. An appropriate intervention in time carries a good prognosis with almost no recurrence.

  10. Mars Molniya Orbit Atmospheric Resource Mining

    Science.gov (United States)

    Mueller, Robert P.; Braun, Robert D.; Sibille, Laurent; Sforzo, Brandon; Gonyea, Keir; Ali, Hisham

    2016-01-01

    This NIAC (NASA Advanced Innovative Concepts) work will focus on Mars and will build on previous efforts at analyzing atmospheric mining at Earth and the outer solar system. Spacecraft systems concepts will be evaluated and traded, to assess feasibility. However the study will primarily examine the architecture and associated missions to explore the closure, constraints and critical parameters through sensitivity studies. The Mars atmosphere consists of 95.5 percent CO2 gas which can be converted to methane fuel (CH4) and Oxidizer (O2) for chemical rocket propulsion, if hydrogen is transported from electrolyzed water on the Mars surface or from Earth. By using a highly elliptical Mars Molniya style orbit, the CO2 atmosphere can be scooped, ram-compressed and stored while the spacecraft dips into the Mars atmosphere at periapsis. Successive orbits result in additional scooping of CO2 gas, which also serves to aerobrake the spacecraft, resulting in a decaying Molniya orbit.

  11. Laser ablation of tumors: current concepts and recent developments

    International Nuclear Information System (INIS)

    Stroszczynski, C.; Gaffke, G.; Gnauck, M.; Ricke, J.; Felix, R.; Puls, R.; Speck, U.; Hosten, N.; Oettle, H.; Hohenberger, P.

    2004-01-01

    Purpose. The purpose of this paper is to present technical innovations and clinical results of percutaneous interventional laser ablation of tumors using new techniques. Methods. Laser ablation was performed in 182 patients (liver tumors: 131, non hepatic tumors - bone, lung, others: 51) after interdisciplinary consensus was obtained. The procedure was done using a combination of imaging modalities (CT/MRI, CT/US) or only closed high field MRI (1.5 T). All patients received an MRI-scan immediately after laser ablation. Results. In 90.9% of the patients with liver tumors, a complete ablation was achieved. Major events occurred in 5.4%. The technical success rate of laser ablation in non-hepatic tumors was high, clinical results differed depending on the treated organ. Conclusions. The treatment of tumors of the liver and other organs up to 5 cm by laser ablation was a safe procedure with a low rate of complications and side effects. Image guidance by MRI is advantageous for precise tumor visualization in all dimensions, therapy monitoring, and control of laser ablation results. (orig.) [de

  12. Tumor macroenvironment and metabolism.

    Science.gov (United States)

    Al-Zoughbi, Wael; Al-Zhoughbi, Wael; Huang, Jianfeng; Paramasivan, Ganapathy S; Till, Holger; Pichler, Martin; Guertl-Lackner, Barbara; Hoefler, Gerald

    2014-04-01

    In this review we introduce the concept of the tumor macroenvironment and explore it in the context of metabolism. Tumor cells interact with the tumor microenvironment including immune cells. Blood and lymph vessels are the critical components that deliver nutrients to the tumor and also connect the tumor to the macroenvironment. Several factors are then released from the tumor itself but potentially also from the tumor microenvironment, influencing the metabolism of distant tissues and organs. Amino acids, and distinct lipid and lipoprotein species can be essential for further tumor growth. The role of glucose in tumor metabolism has been studied extensively. Cancer-associated cachexia is the most important tumor-associated systemic syndrome and not only affects the quality of life of patients with various malignancies but is estimated to be the cause of death in 15%-20% of all cancer patients. On the other hand, systemic metabolic diseases such as obesity and diabetes are known to influence tumor development. Furthermore, the clinical implications of the tumor macroenvironment are explored in the context of the patient's outcome with special consideration for pediatric tumors. Finally, ways to target the tumor macroenvironment that will provide new approaches for therapeutic concepts are described. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Tumor Macroenvironment and Metabolism

    OpenAIRE

    Al-Zhoughbi, Wael; Huang, Jianfeng; Paramasivan, Ganapathy S.; Till, Holger; Pichler, Martin; Guertl-Lackner, Barbara; Hoefler, Gerald

    2014-01-01

    In this review we introduce the concept of the tumor macroenvironment and explore it in the context of metabolism. Tumor cells interact with the tumor microenvironment including immune cells. Blood and lymph vessels are the critical components that deliver nutrients to the tumor and also connect the tumor to the macroenvironment. Several factors are then released from the tumor itself but potentially also from the tumor microenvironment, influencing the metabolism of distant tissues and organ...

  14. Benefits of high aerodynamic efficiency to orbital transfer vehicles

    Science.gov (United States)

    Andrews, D. G.; Norris, R. B.; Paris, S. W.

    1984-01-01

    The benefits and costs of high aerodynamic efficiency on aeroassisted orbital transfer vehicles (AOTV) are analyzed. Results show that a high lift to drag (L/D) AOTV can achieve significant velocity savings relative to low L/D aerobraked OTV's when traveling round trip between low Earth orbits (LEO) and alternate orbits as high as geosynchronous Earth orbit (GEO). Trajectory analysis is used to show the impact of thermal protection system technology and the importance of lift loading coefficient on vehicle performance. The possible improvements in AOTV subsystem technologies are assessed and their impact on vehicle inert weight and performance noted. Finally, the performance of high L/D AOTV concepts is compared with the performances of low L/D aeroassisted and all propulsive OTV concepts to assess the benefits of aerodynamic efficiency on this class of vehicle.

  15. Enrichment of circulating tumor cells from a large blood volume using leukapheresis and elutriation: proof of concept.

    Science.gov (United States)

    Eifler, Robert L; Lind, Judith; Falkenhagen, Dieter; Weber, Viktoria; Fischer, Michael B; Zeillinger, Robert

    2011-03-01

    The aim of this study was to determine the applicability of a sequential process using leukapheresis, elutriation, and fluorescence-activated cell sorting (FACS) to enrich and isolate circulating tumor cells from a large blood volume to allow further molecular analysis. Mononuclear cells were collected from 10 L of blood by leukapheresis, to which carboxyfluorescein succinimidyl ester prelabeled CaOV-3 tumor cells were spiked at a ratio of 26 to 10⁶ leukocytes. Elutriation separated the spiked leukapheresates primarily by cell size into distinct fractions, and leukocytes and tumor cells, characterized as carboxyfluorescein succinimidyl ester positive, EpCAM positive and CD45 negative events, were quantified by flow cytometry. Tumor cells were isolated from the last fraction using FACS or anti-EpCAM coupled immunomagnetic beads, and their recovery and purity determined by fluorescent microscopy and real-time PCR. Leukapheresis collected 13.5 x 10⁹ mononuclear cells with 87% efficiency. In total, 53 to 78% of spiked tumor cells were pre-enriched in the last elutriation fraction among 1.6 x 10⁹ monocytes. Flow cytometry predicted a circulating tumor cell purity of ~90% giving an enrichment of 100,000-fold following leukapheresis, elutriation, and FACS, where CaOV-3 cells were identified as EpCAM positive and CD45 negative events. FACS confirmed this purity. Alternatively, immunomagnetic bead adsorption recovered 10% of tumor cells with a median purity of 3.5%. This proof of concept study demonstrated that elutriation and FACS following leukapheresis are able to enrich and isolate tumor cells from a large blood volume for molecular characterization. Copyright © 2010 International Clinical Cytometry Society.

  16. Curative radiotherapy for primary orbital lymphoma

    International Nuclear Information System (INIS)

    Bhatia, Sudershan; Paulino, Arnold C.; Buatti, John M.; Mayr, Nina A.; Wen, B.-C.

    2002-01-01

    Purpose: To review our institutional experience with primary orbital lymphoma and determine the prognostic factors for survival, local control, and distant metastases. In addition, we also analyzed the risk factors for complications in the radiotherapeutic management of this tumor. Methods and Materials: Between 1973 and 1998, 47 patients (29 women [62%] and 18 men [38%], median age 69 years, range 32-89) with Stage IAE orbital lymphoma were treated with curative intent at one department. Five had bilateral orbital involvement. The tumor was located in the eyelid and extraocular muscles in 23 (44%), conjunctiva in 17 (33%), and lacrimal apparatus in 12 (23%). The histologic features according to the World Heath Organization classification of lymphoid neoplasms was follicular lymphoma in 25, extranodal marginal zone B-cell lymphoma of mucosa-associated lymphoid tissue type in 8, diffuse large B-cell lymphoma in 12, mantle cell lymphoma in 6, and peripheral T-cell lymphoma in 1. For the purposes of comparison with the existing literature on orbital lymphomas, the grading system according to the Working Formulation was also recorded. The histologic grade was low in 33 (63%), intermediate in 18 (35%), and high in 1 (2%). All patients were treated with primary radiotherapy alone. The median dose for low-grade tumors was 3000 cGy (range 2000-4020); the median dose for intermediate and high-grade tumors was 4000 cGy (range 3000-5100). A lens-sparing approach was used in 19 patients (37%). Late complications for the lens and cornea were scored according to the subjective, objective, management, and analytic (SOMA) scale of the Late Effects of Normal Tissue (LENT) scoring system. The median follow-up was 55 months (range 6-232). Results: The local control rate was 100% in the 52 orbits treated. The 5-year overall survival and relapse-free survival rate was 73.6% and 65.5%, respectively. Tumor grade and location did not predict for overall survival or relapse-free survival

  17. Current concepts in diagnosis of unusual salivary gland tumors

    Directory of Open Access Journals (Sweden)

    Ajay Kumar Bansal

    2012-01-01

    Full Text Available Salivary gland tumors are relatively uncommon and account for approximately 3-6% of all neoplasms of the head and neck. Tumors mostly involve the major salivary glands, 42.9-90% of which occur in the parotid glands and 8-19.5% in the sub-mandibular glands; tumors in the sub-lingual glands being uncommon. Despite the plethora of different malignant salivary gland tumor presented to pathologists for diagnosis, there is consensus on a limited number of pathologic observations that determine treatment and outcome. There are few absolutes in salivary gland tumor diagnosis given the marked spectrum and overlap of differentiated cell types that participate in the numerous benign and malignant tumors. Thus, there are enumerating antibodies that may be helpful in resolving difficult differential diagnoses when applied with astute morphologic correlation. In general, immunohistochemistry as an ancillary diagnostic tool should be used sparingly and wisely as a morphologic adjunct because of the lack of specificity of many markers for specific histologic tumor types. The aim of this review is to discuss the molecular profiling of salivary gland neoplasms and correlate this with histogenesis of salivary gland neoplasms. We have elected to discuss and illustrate some of the unusual salivary gland tumors that the practicing pathologist find difficult to diagnose. These have been selected because they readily simulate each other but have very different clinical therapies and, therefore, should be included routinely in differential diagnosis.

  18. Investigation of CT and MRI findings of cranio-orbital communicating lesions

    International Nuclear Information System (INIS)

    Wang Zhenchang; Jiang Dingyao; Xian Junfang; An Yuzhi; Zhang Tianming; Li Bin; Liang Xihong; Yang Bentao

    2001-01-01

    Objective: To investigate CT and MRI findings of cranio-orbital communicating lesions so as to find out communicating passages and their imaging features. Methods: Fifty-one cases of cranio-orbital communicating lesions confirmed by pathology and follow-up results were studied. CT was performed in all cases and MRI in 45 cases. Post-contrast CT and MRI was completed in 44 cases. Results: There were 31 cases (60.8%) with lesions communicating between the orbital cavity and the cranial cavity through optic canal or superior orbital fissure showing communicating soft tissue mass and enlargement of optic canal or superior orbital fissure. Four cases of optic gliomas involving optic nerve and optic chiasm, three cases with meningiomas of optic nerve sheath, and 2 cases with retinoblastoma involving optic nerve and optic chiasm showed cranio-orbital communicating masses through the optic canal. Cranio-orbital communicating mass with enlargement of superior orbital fissure was found in 22 patients including 5 meningiomas, 4 neurogenic tumors, 1 dermoid cyst, 3 inflammatory pseudotumors, 2 Tolosa-Hunt syndromes and 7 metastases from nasopharyngeal carcinoma. In addition, 20 of 51 cases (39.2%) communicated through perforating blood vessels or bony defect resulted from tumor destruction. Of these lesions, there were 10 metastases showing bone destruction in orbital walls, 5 cases with en plaque meningiomas of sphenoid bone with marked hyperostosis and widespread dural involvement, 1 chondrosarcoma involving frontal lobe and orbit, 3 adenoid cystic carcinomas involving frontal lobe, and 1 malignant meningioma with bone destruction of the superior orbital wall. Conclusion: CT and MRI could definitely demonstrate communicating passages of cranio-orbital communicating lesions and their imaging changes, which could contribute to diagnosis and differential diagnosis and provide valuable information for determining treatment measures and surgical approach

  19. Orbital MALT Lymphoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Shobha G Pai

    2004-08-01

    Full Text Available A case of orbital MALT (mucous associated lymphoid tissue lymphoma is reported for its rarity. It presented as a large tumor obscuring the whole eye with loss of vision, without any signs of dissemination and remained free of recurrence or metastasis 12 months after undergoing simple surgical excision.

  20. MRI of orbital hydroxyapatite implants

    International Nuclear Information System (INIS)

    Flanders, A.E.; De Potter P.; Rao, V.M.; Tom, B.M.; Shields, C.L.; Shields, J.A.

    1996-01-01

    Our aim was to use MRI for the postsurgical assessment of a new form of integrated orbital implant composed of a porous calcium phosphate hydroxyapatite substrate. We studied ten patients 24-74 years of age who underwent enucleation and implantation of a hydroxyapatite ball; 5-13 months after surgery, each patient was examined by spin-echo MRI, with fat suppression and gadolinium enhancement. Fibrovascular ingrowth was demonstrated in all ten patients as areas of enhancement at the periphery of the hydroxyapatite sphere that extended to the center to a variable degree. The radiologist should aware of the MRI appearances of the coralline hydroxyapatite orbital implant since it is now widely used following enucleation. MRI is a useful means to determine successful incorporation of the substrate into the orbital tissues. The normal pattern of contrast enhancement should not be mistaken for recurrent tumor or infection. (orig.)

  1. New conception in the theory of chemical bonding; the role of core and valence atomic orbitals in formation of chemical bonds

    International Nuclear Information System (INIS)

    Kostikova, G.P.; Kostikov, Yu.P.; Korol'kov, D.V.

    1986-01-01

    An analysis of x-ray photoelectron spectra leads to a simple and consistent conception in the theory of chemical bonding, which satisfies (unlike the simple MO-LCAO theory) the virial theorem and defines the roles of the core and valence atomic orbitals in the formation of chemical bonds. Its essence is clear from the foregoing: the exothermic effects of the formation of complexes are caused by the lowering of the energies of the core levels of the central atoms with simultaneous small changes in the energies of the core levels of the ligands despite the significant destabilization of the delocalized valence MO's in comparison to the orbital energies of the corresponding free atoms. In order to confirm these ideas, they recorded the x-ray photoelectron spectra of the valence region and the inner levels of single-crystal silicon carbide, silicon, and graphite

  2. Management of periorbital basal cell carcinoma with orbital invasion.

    Science.gov (United States)

    Sun, Michelle T; Wu, Albert; Figueira, Edwin; Huilgol, Shyamala; Selva, Dinesh

    2015-11-01

    Basal cell carcinoma (BCC) is the most common eyelid malignancy; however, orbital invasion by periocular BCC is rare, and management remains challenging. Established risk factors for orbital invasion by BCC include male gender, advanced age, medial canthal location, previous recurrences, large tumor size, aggressive histologic subtype and perineural invasion. Management requires a multidisciplinary approach with orbital exenteration remaining the treatment of choice. Globe-sparing treatment may be appropriate in selected patients and radiotherapy and chemotherapy are often used as adjuvant therapies for advanced or inoperable cases, although the evidence remains limited. We aim to summarize the presentation and treatment of BCC with orbital invasion to better guide the management of this complex condition.

  3. Aerobrake concepts for NTP systems study

    Science.gov (United States)

    Cruz, Manuel I.

    1992-01-01

    Design concepts are described for landing large spacecraft masses on the Mars surface in support of manned missions with interplanetary transportation using Nuclear Thermal Propulsion (NTP). Included are the mission and systems analyses, trade studies and sensitivity analyses, design analyses, technology assessment, and derived requirements to support this concept. The mission phases include the Mars de-orbit, entry, terminal descent, and terminal touchdown. The study focuses primarily on Mars surface delivery from orbit after Mars orbit insertion using an NTP. The requirements associated with delivery of logistical supplies, habitats, and other equipment on minimum energy Earth to Mars transfers are also addressed in a preliminary fashion.

  4. Reconstruction of Midface and Orbital Wall Defects After Maxillectomy and Orbital Content Preservation With Titanium Mesh and Fascia Lata: 3-Year Follow-Up.

    Science.gov (United States)

    Motiee-Langroudi, Maziar; Harirchi, Iraj; Amali, Amin; Jafari, Mehrdad

    2015-12-01

    To describe the authors' experience in the reconstruction of patients after total maxillectomy with preservation of orbital contents for maxillary tumors using titanium mesh and autogenous fascia lata, where no setting for free flap reconstruction is available. Twelve consecutive patients with paranasal sinus tumors underwent total maxillectomy without orbital exenterations and primary reconstruction. The defects were reconstructed by titanium mesh in combination with autogenous fascia lata in the orbital floor performed by 1 surgical team. Titanium mesh (0.2 mm thick) was contoured and fixed to reconstruct the orbital floor and obtain midface projection. Fascia lata was used to cover the titanium mesh along the orbital floor to prevent fat entrapment in the mesh holes. The most common pathology was squamous cell carcinoma (50%). Patients' mean age was 45.66 years (33 to 74 yr). The mean follow-up period was 35.2 months (30 to 49 months). During follow-up, no infection or foreign body reaction was encountered. Extrusion of titanium mesh occurred in 4 patients who underwent postoperative radiotherapy. Two cases of mild diplopia at extreme gaze occurred early during the postoperative period that resolved after a few months. Placing fascia lata between the titanium mesh surface of the orbital implant and the orbital contents was successful in preventing long-term diplopia or dystopia. Nevertheless, exposure of the titanium implant through the skin surface represented a complication of this technique in 25% of patients. Further studies are required with head-to-head comparisons of artificial materials and free flaps for reconstruction of maxillectomy defects. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Gamma knife radiosurgery for benign cavernous sinus tumors. Treatment concept and outcomes in 120 cases

    International Nuclear Information System (INIS)

    Hayashi, Motohiro; Chernov, Mikhail; Tamura, Noriko

    2012-01-01

    Availability of modern computer-aided robotized devices, such as the Automatic Positioning System (APS TM ; Elekta Instruments AB, Stockholm, Sweden) and Perfexion TM (Elekta Instruments AB), allowed us to develop the original concept of robotic gamma knife microradiosurgery, which is based on the very precise irradiation of the lesion with regard to conformity and selectivity; intentional avoidance of the excessive irradiation of functionally-important anatomical structures, particularly cranial nerves, located both within and in the vicinity of the target; and delivery of sufficient irradiation energy to the tumor with the intention to attain lesion shrinkage, while keeping the marginal dose sufficiently low for prevention of possible complications. The results of such treatment strategy were evaluated retrospectively in 120 patients with benign cavernous sinus neoplasms (pituitary adenomas, meningiomas, schwannomas, and hemangiomas), who were followed up from 24 to 78 months (mean 47 months) after radiosurgery. Tumor growth control and shrinkage rates were 98% and 68%, respectively. More than 50% volume reduction was noted in 25% of lesions. The most prominent volumetric tumor response was observed in hemangiomas, followed by schwannomas, pituitary adenomas, and meningiomas. Treatment-related complications were marked in 7% of cases, and were mainly related to transient isolated cranial neuropathy appearing within several months after radiosurgery. Major morbidity was limited to one patient (0.8%). Application of microradiosurgical treatment principles provides effective and safe management of benign cavernous sinus tumors and is associated with high probability of lesion shrinkage and minimal risk of complications. (author)

  6. Noninvasive referencing of intraocular tumors for external beam radiation therapy using optical coherence tomography: A proof of concept

    International Nuclear Information System (INIS)

    Rüegsegger, Michael B.; Steiner, Patrick; Kowal, Jens H.; Geiser, Dominik; Pica, Alessia; Aebersold, Daniel M.

    2014-01-01

    Purpose: External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). Methods: A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. Results: Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. Conclusions: The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors

  7. Iodine-125 orbital brachytherapy with a prosthetic implant in situ

    Energy Technology Data Exchange (ETDEWEB)

    Stannard, Clare [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Radiation Oncology; Maree, Gert; Munro, Roger [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Medical Physics; Lecuona, Karin [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Ophthalmology; Sauerwein, Wolfgang [Universitaetsklinikum Essen (Germany). Strahlenklinik, NCTeam

    2011-05-15

    Purpose: Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis. Patients and Methods: This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy. Results: The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good. Conclusion: Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant. (orig.)

  8. Tumors of the optic nerve

    DEFF Research Database (Denmark)

    Lindegaard, Jens; Heegaard, Steffen

    2009-01-01

    A variety of lesions may involve the optic nerve. Mainly, these lesions are inflammatory or vascular lesions that rarely necessitate surgery but may induce significant visual morbidity. Orbital tumors may induce proptosis, visual loss, relative afferent pupillary defect, disc edema and optic...... atrophy, but less than one-tenth of these tumors are confined to the optic nerve or its sheaths. No signs or symptoms are pathognomonic for tumors of the optic nerve. The tumors of the optic nerve may originate from the optic nerve itself (primary tumors) as a proliferation of cells normally present...... in the nerve (e.g., astrocytes and meningothelial cells). The optic nerve may also be invaded from tumors originating elsewhere (secondary tumors), invading the nerve from adjacent structures (e.g., choroidal melanoma and retinoblastoma) or from distant sites (e.g., lymphocytic infiltration and distant...

  9. Effects of DeOrbitSail as applied to Lifetime predictions of Low Earth Orbit Satellites

    Science.gov (United States)

    Afful, Andoh; Opperman, Ben; Steyn, Herman

    2016-07-01

    Orbit lifetime prediction is an important component of satellite mission design and post-launch space operations. Throughout its lifetime in space, a spacecraft is exposed to risk of collision with orbital debris or operational satellites. This risk is especially high within the Low Earth Orbit (LEO) region where the highest density of space debris is accumulated. This paper investigates orbital decay of some LEO micro-satellites and accelerating orbit decay by using a deorbitsail. The Semi-Analytical Liu Theory (SALT) and the Satellite Toolkit was employed to determine the mean elements and expressions for the time rates of change. Test cases of observed decayed satellites (Iridium-85 and Starshine-1) are used to evaluate the predicted theory. Results for the test cases indicated that the theory fitted observational data well within acceptable limits. Orbit decay progress of the SUNSAT micro-satellite was analysed using relevant orbital parameters derived from historic Two Line Element (TLE) sets and comparing with decay and lifetime prediction models. This paper also explored the deorbit date and time for a 1U CubeSat (ZACUBE-01). The use of solar sails as devices to speed up the deorbiting of LEO satellites is considered. In a drag sail mode, the deorbitsail technique significantly increases the effective cross-sectional area of a satellite, subsequently increasing atmospheric drag and accelerating orbit decay. The concept proposed in this study introduced a very useful technique of orbit decay as well as deorbiting of spacecraft.

  10. Design Concepts for a Small Space-Based GEO Relay Satellite for Missions Between Low Earth and near Earth Orbits

    Science.gov (United States)

    Bhasin, Kul B.; Warner, Joseph D.; Oleson, Steven; Schier, James

    2014-01-01

    The main purpose of the Small Space-Based Geosynchronous Earth orbiting (GEO) satellite is to provide a space link to the user mission spacecraft for relaying data through ground networks to user Mission Control Centers. The Small Space Based Satellite (SSBS) will provide services comparable to those of a NASA Tracking Data Relay Satellite (TDRS) for the same type of links. The SSBS services will keep the user burden the same or lower than for TDRS and will support the same or higher data rates than those currently supported by TDRS. At present, TDRSS provides links and coverage below GEO; however, SSBS links and coverage capability to above GEO missions are being considered for the future, especially for Human Space Flight Missions (HSF). There is also a rising need for the capability to support high data rate links (exceeding 1 Gbps) for imaging applications. The communication payload on the SSBS will provide S/Ka-band single access links to the mission and a Ku-band link to the ground, with an optical communication payload as an option. To design the communication payload, various link budgets were analyzed and many possible operational scenarios examined. To reduce user burden, using a larger-sized antenna than is currently in use by TDRS was considered. Because of the SSBS design size, it was found that a SpaceX Falcon 9 rocket could deliver three SSBSs to GEO. This will greatly reduce the launch costs per satellite. Using electric propulsion was also evaluated versus using chemical propulsion; the power system size and time to orbit for various power systems were also considered. This paper will describe how the SSBS will meet future service requirements, concept of operations, and the design to meet NASA users' needs for below and above GEO missions. These users' needs not only address the observational mission requirements but also possible HSF missions to the year 2030. We will provide the trade-off analysis of the communication payload design in terms of

  11. Current Concepts on Gastric Carcinoid Tumors

    Directory of Open Access Journals (Sweden)

    George C. Nikou

    2012-01-01

    Full Text Available Gastric carcinoid tumors (GCs are rare lesions representing less than 10% of carcinoid tumors and less than 1% of all stomach neoplasms. There are three distinct types of gastric carcinoids; type I includes the vast majority (70–85% of these neoplasms that are closely linked to chronic atrophic gastritis. Type II which accounts for 5–10 %, is associated with Zollinger-Ellison syndrome and often occurs in the context of multiple endocrine neoplasia type 1. Type III, finally, represents 15–25% of gastric carcinoids and is characterized by a far more aggressive course. The optimal clinical approach to GCs remains to be elucidated, depending upon type, size, and number of carcinoids. While there is universal agreement about the surgical treatment of type III GCs, current options for type I and II include simple surveillance, endoscopic polypectomy, surgical excision associated with or without surgical antrectomy, or total gastrectomy. Moreover, the introduction of somatostatin analogues could represent another therapeutic option.

  12. Large Deployable Reflector (LDR) system concept and technology definition study. Volume 1: Executive summary, analyses and trades, and system concepts

    Science.gov (United States)

    Agnew, Donald L.; Jones, Peter A.

    1989-01-01

    A study was conducted to define reasonable and representative large deployable reflector (LDR) system concepts for the purpose of defining a technology development program aimed at providing the requisite technological capability necessary to start LDR development by the end of 1991. This volume includes the executive summary for the total study, a report of thirteen system analysis and trades tasks (optical configuration, aperture size, reflector material, segmented mirror, optical subsystem, thermal, pointing and control, transportation to orbit, structures, contamination control, orbital parameters, orbital environment, and spacecraft functions), and descriptions of three selected LDR system concepts. Supporting information is contained in appendices.

  13. Inverted papilloma of lacrimal sac invading into the orbit: Case report and review of literature

    Directory of Open Access Journals (Sweden)

    Alistair W Hardy

    2015-01-01

    Full Text Available Inverted papilloma (IP is a sinonasal tumor of benign etiology with local invasion and malignant potential. IP arising in lacrimal sac invading the orbit is extremely rare with only one case reported so far. The presented case appears to be the second such case reported in the literature. A 60-year-old Caucasian male presented with a medial canthal mass and epiphora. Incisional biopsy confirmed a transitional neoplasm. The lesion was completely excised enbloc with clear margins by using a Weber-Ferguson incision; orbital clearance and nasolacrimalfossa clearance was achieved via a medial maxillectomy. Enbloc resection of orbital and nasolacrimal parts of the tumor with clear margins is recommended.

  14. Changes of Space Debris Orbits After LDR Operation

    Science.gov (United States)

    Wnuk, E.; Golebiewska, J.; Jacquelard, C.; Haag, H.

    2013-09-01

    A lot of technical studies are currently developing concepts of active removal of space debris to protect space assets from on orbit collision. For small objects, such concepts include the use of ground-based lasers to remove or reduce the momentum of the objects thereby lowering their orbit in order to facilitate their decay by re-entry into the Earth's atmosphere. The concept of the Laser Debris Removal (LDR) system is the main subject of the CLEANSPACE project. One of the CLEANSPACE objectives is to define a global architecture (including surveillance, identification and tracking) for an innovative ground-based laser solution, which can remove hazardous medium debris around selected space assets. The CLEANSPACE project is realized by a European consortium in the frame of the European Commission Seventh Framework Programme (FP7), Space topic. The use of sequence of laser operations to remove space debris, needs very precise predictions of future space debris orbital positions, on a level even better than 1 meter. Orbit determination, tracking (radar, optical and laser) and orbit prediction have to be performed with accuracy much better than so far. For that, the applied prediction tools have to take into account all perturbation factors that influence object orbit. The expected object's trajectory after the LDR operation is a lowering of its perigee. To prevent the debris with this new trajectory to collide with another object, a precise trajectory prediction after the LDR sequence is therefore the main task allowing also to estimate re-entry parameters. The LDR laser pulses change the debris object velocity v. The future orbit and re-entry parameters of the space debris after the LDR engagement can be calculated if the resulting ?v vector is known with the sufficient accuracy. The value of the ?v may be estimated from the parameters of the LDR station and from the characteristics of the orbital debris. However, usually due to the poor knowledge of the debris

  15. Orbital lymphoma masquerading as thyroid ophthalmopathy.

    Science.gov (United States)

    Boyce, P J

    1998-10-01

    Lymphoid tumors are known to originate within the lacrimal gland and orbital fat. Ocular findings commonly seen are a palpable mass with proptosis and downward displacement of the globe. Graves' ophthalmopathy is the most common orbital pathology occurring in the general population. Signs and symptoms of Graves' ophthalmopathy, such as unilateral or bilateral proptosis, double vision, limitation of movement of the extraocular muscles, are not specific for this condition. A 57-year-old man came to us with a chief symptom of "eye swelling" for the last 3 years. He had been diagnosed with hyperthyroidism and had received three surgical procedures for orbital decompression. Clinical findings included limitation of upward and downward gaze, exophthalmometry readings of 30 1/2 mm O.D. and 31 mm O.S. (with a base of 112), and profound proptosis with fatty tissue prolapse. Subsequent thyroid testing revealed euthyroid status and computed tomography scan revealed orbital lymphoma. Orbital involvement from a malignant nodular histiocytic lymphoma resulted in a proptosis similar to that observed in Graves' ophthalmopathy. This very unusual presentation of orbital lymphoma mimicked Graves' disease so closely that the true cause was overlooked. This case emphasizes the need to include space-occupying lesions in the differential diagnosis of proptosis and gaze restrictions. The disease process and controversial management strategies are discussed.

  16. Tumor orbitário como primeira manifestação clínica de mieloma múltiplo: relato de caso Orbital tumor as the first clinical manifestation of multiple myeloma: case report

    Directory of Open Access Journals (Sweden)

    Aline Ruilowa de Pinho

    2009-02-01

    Full Text Available O acometimento da órbita pelo mieloma múltiplo é raro. Neste estudo, os autores descrevem um caso infrequente de proptose como primeiro sinal clínico do mieloma múltiplo. A presença de lesão orbitária expansiva associada a destruição do rebordo superior da órbita, notáveis à tomografia computadorizada, fez com que a diagnóstico de mieloma múltiplo fosse considerado. Aspectos diagnósticos e terapêuticos são discutidos.Orbital involvement by multiple myeloma is rare. In this study, the authors report an unusual case of proptosis as the first clinical sign of multiple myeloma. The presence of an orbital lesion expanding and destroying the superior orbital rim, disclosed by computed tomography, lead us to consider multiple myeloma. Diagnostic and therapeutic aspects are discussed.

  17. HMB-45 negative angiomyolipoma of the orbit: a case report and review of the literature.

    Science.gov (United States)

    Lin, Che-Yu; Tsai, Chieh-Chih; Kau, Hui-Chuan; Yu, Wei-Kuang; Kao, Shu-Ching; Liu, Catherine Jui-Ling

    2016-01-11

    Angiomyolipoma is a benign mesenchymal tumor composed of variable amounts of smooth muscle, adipose tissue and thick-walled blood vessels, and usually named PEComas (perivascular epithelioid cell tumors). PEComas share overlapping histopathological features with epithelioid cells along a perivascular distribution and characteristic immunohistochemistry with coexpression of myoid and melanocytic markers (HMB-45 /or Melan-A). We report the first case of primary orbital angiomyolipoma with negative melanocytic marker. An 80-year-old Asian woman had a 2-year history of progressive swelling in the left upper eyelid. External examination revealed 3 cm of relative proptosis of the left eye and a palpable mass in the left superonasal orbit. Computed tomographic scan demonstrated a circumscribed, heterogeneous orbital mass. Excision biopsy was done and the histological finding demonstrated the orbital mass was composed of mature adipocytes, intermingled with spindle or oval-shaped cells, and accompanied by thick-walled blood vessels. Immunohistochemically, tumor cells were positive for CD34 and HHF-35, but negative for cytokeratin, HMB-45 and Melan-A. The diagnosis of angiomyolipoma was made. No recurrence was noted at 2-year follow-up. In our case, the HMB-45 negativity may be explained by the rarity of the epithelioid cells, and the HMB-45 positivity is often weaker or absent in spindle cells. Angiomyolipoma, although rare, should be added to the differential diagnosis of space-occupying orbital lesion.

  18. Radiation therapy for primary orbital lymphoma

    International Nuclear Information System (INIS)

    Chao, Cliff K.S.; Lin Hsiusan; Rao Devineni, V.; Smith, Morton

    1995-01-01

    Purpose: The influence of tumor size, grade, thoroughness of staging workup, and radiation dose on disease control, radiation-related complications, and incidence of systemic progression of primary orbital lymphoma is analyzed. Methods and Materials: Twenty patients with Stage I primary orbital lymphoma were treated from August 1976 through August 1991 at Mallinckrodt Institute of Radiology. Staging workups included physical examination, chest x-ray, complete blood count (CBC), liver function test, and computerized tomography (CT) scan of the orbit, abdomen, and pelvis. Nineteen patients had bone marrow biopsy. The histological types based on the National Cancer Institute working formulation were 9 low-grade and 11 intermediate-grade, including five lymphocytic lymphomas of intermediate differentiation. The extension of disease and the volume of tumor were evaluated by CT scan of the orbit. The most commonly used radiation therapy technique was single anterior direct field with 4 MV or 6 MV photons. Lens was shielded or not treated in eight patients. Dose ranged from 20 to 43.2 Gy. Thirteen of 20 patients received 30 Gy. Minimum follow-up was 24 months (median, 4 years). Results: Local control was achieved in all 20 patients. One patient with lymphocytic lymphoma with intermediate differentiation developed disseminated disease. Actuarial disease-free survival (DFS) was 100% and 90% at 2 and 5 years, respectively. No retinopathy was observed. Cataracts were noted in seven patients at 1 to 10 years following irradiation (median, 2 years). Three patients developed lacrimal function disorder, however, no corneal ulceration occurred. Conclusions: Thirty Gy in 15 fractions appears to be a sufficient dose for local control with acceptable morbidity, especially for low-grade, as well as certain types of intermediate-grade lymphomas, such as diffuse small cleaved cell and lymphocytic lymphoma of intermediate differentiation. Systemic dissemination is minimal, provided local

  19. Radiation therapy for primary orbital lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Cliff K.S.; Hsiusan, Lin; Rao Devineni, V; Smith, Morton

    1995-02-15

    Purpose: The influence of tumor size, grade, thoroughness of staging workup, and radiation dose on disease control, radiation-related complications, and incidence of systemic progression of primary orbital lymphoma is analyzed. Methods and Materials: Twenty patients with Stage I primary orbital lymphoma were treated from August 1976 through August 1991 at Mallinckrodt Institute of Radiology. Staging workups included physical examination, chest x-ray, complete blood count (CBC), liver function test, and computerized tomography (CT) scan of the orbit, abdomen, and pelvis. Nineteen patients had bone marrow biopsy. The histological types based on the National Cancer Institute working formulation were 9 low-grade and 11 intermediate-grade, including five lymphocytic lymphomas of intermediate differentiation. The extension of disease and the volume of tumor were evaluated by CT scan of the orbit. The most commonly used radiation therapy technique was single anterior direct field with 4 MV or 6 MV photons. Lens was shielded or not treated in eight patients. Dose ranged from 20 to 43.2 Gy. Thirteen of 20 patients received 30 Gy. Minimum follow-up was 24 months (median, 4 years). Results: Local control was achieved in all 20 patients. One patient with lymphocytic lymphoma with intermediate differentiation developed disseminated disease. Actuarial disease-free survival (DFS) was 100% and 90% at 2 and 5 years, respectively. No retinopathy was observed. Cataracts were noted in seven patients at 1 to 10 years following irradiation (median, 2 years). Three patients developed lacrimal function disorder, however, no corneal ulceration occurred. Conclusions: Thirty Gy in 15 fractions appears to be a sufficient dose for local control with acceptable morbidity, especially for low-grade, as well as certain types of intermediate-grade lymphomas, such as diffuse small cleaved cell and lymphocytic lymphoma of intermediate differentiation. Systemic dissemination is minimal, provided local

  20. Feasibility of a responsive, hybrid propulsion augmented, Vertical-Takeoff-and-Landing, Single-Stage-to-Orbit launch system

    Science.gov (United States)

    Pelaccio, Dennis G.

    1996-03-01

    A novel, reusable, Vertical-Takeoff-and-Landing, Single-Stage-to-Orbit (VTOL/SSTO) launch system concept, named HYP-SSTO, is presented in this paper. This launch vehicle system concept uses a highly coupled, main high performance liquid oxygen/liquid hydrogen (LOX/LH2) propulsion system, that is used only for launch, with a hybrid auxiliary propulsion system which is used during final orbit insertion, major orbit maneuvering, and landing propulsive burn phases of flight. By using a hybrid propulsion system for major orbit maneuver burns and landing, this launch system concept has many advantages over conventional VTOL/SSTO concepts that use LOX/LH2 propulsion system(s) burns for all phases of flight. Because hybrid propulsion systems are relatively simple and inert by their nature, this concept has the potential to support short turnaround times between launches, be economical to develop, and be competitive in terms of overall system life-cycle cost. This paper provides a technical description of the novel, reusable HYP-SSTO launch system concept. Launch capability performance, as well as major design and operational system attributes, are identified and discussed.

  1. Phase-space distributions and orbital angular momentum

    Directory of Open Access Journals (Sweden)

    Pasquini B.

    2014-06-01

    Full Text Available We review the concept of Wigner distributions to describe the phase-space distributions of quarks in the nucleon, emphasizing the information encoded in these functions about the quark orbital angular momentum.

  2. Primitive neuroectodermal tumor of the orbit in a 5-year-old girl with microphthalmia

    DEFF Research Database (Denmark)

    Alyahya, Ghassan Ayish Jabur; Heegaard, Steffen; Fledelius, Hans C.

    2000-01-01

    ophthalmology, primitive neuroectodermal tumor (PNET), Ewing's sarcoma, small round-cell tumors, retinoblastoma, medulloepithelioma, microphthalmia, orbitotomy......ophthalmology, primitive neuroectodermal tumor (PNET), Ewing's sarcoma, small round-cell tumors, retinoblastoma, medulloepithelioma, microphthalmia, orbitotomy...

  3. Granular cell tumor with orbital involvement in a child

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Fabiano [Universidade Estadual de Campinas (FCM/UNICAMP), SP (Brazil). Fac. de Ciencias Medicas. Dept. de Radiologia; Iyeyasu, Josie Naomi; Carvalho, Keila Monteiro de [Universidade Estadual de Campinas (FCM/UNICAMP), SP (Brazil). Fac. de Ciencias Medicas. Dept. de Oftalmo-Otorrinolaringologia; Altemani, Albina Messias [Universidade Estadual de Campinas (FCM/UNICAMP), SP (Brazil). Fac. de Ciencias Medicas. Dept. de Anatomia Patologica

    2011-09-15

    The authors report a rare case of granular cell tumor in the left medial rectus muscle of a seven-year-old boy. Clinical, pathologic and radiologic findings of the present case are described and a brief literature review is undertaken. (author)

  4. Granular cell tumor with orbital involvement in a child

    International Nuclear Information System (INIS)

    Reis, Fabiano; Iyeyasu, Josie Naomi; Carvalho, Keila Monteiro de; Altemani, Albina Messias

    2011-01-01

    The authors report a rare case of granular cell tumor in the left medial rectus muscle of a seven-year-old boy. Clinical, pathologic and radiologic findings of the present case are described and a brief literature review is undertaken. (author)

  5. CT findings of orbital inflammatory diseases

    International Nuclear Information System (INIS)

    Kim, Jang Min; Shin, Hyun Joon; Kim, Jung Hyuk; Suh, Won Hyuck

    1991-01-01

    Twenty-nine patients with orbital inflammatory disease (OIDs) were retrospectively reviewed in order to analyze detailed CT findings which might aid in differentiating OIDs. This study comprised 18 pseudotumors, 5 thyroid ophthalmopathies, and 6 cases of orbital cellulitis. CT scans of the pseudotumors showed various findings such as exophthalmos, scleritis, myositis of the extraocular muscle (MOM), and bone lesion. Bone lesions of the pseudo tumors, which have been rarely reported, were present in 7 cases in our series. Bilateral exophthalmos, myositis, and retrobulbar fat deposition were readily detected by CT in thyroid ophthalmopathy, and, in addition, we found bone erosions involving the orbital apices in 2 cases. In orbital cellulitis, extraorbital soft tissue swelling and lateral displacement of the medial rectus muscle in cases with ethmoiditis were the most conspicuous features. In summary, because of the overlapping CT findings in OIDs, careful examination of CT findings regarding the mode of EOM involvement and the presence or absence of scleritis or sinusitis might help narrow down the differential diagnosis. A pseudotumor with bone lesions could be mistaken as a malignant lesion, and therefore it is necessary to correlate clinical features with CT findings for an accurate diagnosis

  6. A unique method of retaining orbital prosthesis with attachment systems - a clinical report.

    Science.gov (United States)

    Guttal, Satyabodh S; Akash, N R; Prithviraj, D R; Lekha, K

    2014-06-01

    Diminution of the orbital contents post-surgical removal of a malignant tumor can have a severe psychological impact on the patient in terms of function and esthetics. Therefore, esthetic remedy should be planned subsequently, since tumor obliteration precedes cosmetic concern. A convenient option for successful rehabilitation in such patients is a simple, user-friendly, removable orbital prosthesis. Retention of the prosthesis is one of the key factors for the successful rehabilitation. Spectacle frame, conformers, adhesives, osseointegrated implants, magnets or buttons have been used to impart retention to the prosthesis. The use of semi precision attachments in maxillofacial prostheses is limited to the osseointegrated prostheses. This case report describes a conventional spectacle frame technique, to retain the silicone orbital prosthesis using two different types of stud attachments viz., dalla bona and O-ring attachment systems. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  7. Image-charge-induced localization of molecular orbitals at metal-molecule interfaces

    DEFF Research Database (Denmark)

    Strange, M.; Thygesen, K. S.

    2012-01-01

    Quasiparticle (QP) wave functions, also known as Dyson orbitals, extend the concept of single-particle states to interacting electron systems. Here we employ many-body perturbation theory in the GW approximation to calculate the QP wave functions for a semiempirical model describing a pi-conjugat......Quasiparticle (QP) wave functions, also known as Dyson orbitals, extend the concept of single-particle states to interacting electron systems. Here we employ many-body perturbation theory in the GW approximation to calculate the QP wave functions for a semiempirical model describing a pi...

  8. SINONASAL AND ORBITAL MALIGNANT NEOPLASMS IN PEDIATRIC POPULATION: A STUDY FROM A TERTIARY CARE CENTRE IN INDIA

    Directory of Open Access Journals (Sweden)

    Koyela Mondal

    2015-01-01

    Full Text Available NTRODUCTION : Paranasal and extra - ocular orbital malignant tumors are comparatively rare in pediatric patients and difficult to diagnose early. Malignant lesions in this region tend to be locally aggressive, often presenting at an advanced stage. Non osseous, extra ocular orbital tumors represent a different histologic spectrum in children than in adults. AIMS: To study the spectrum of malignant lesions of paranasal sinuses and orbital area in patients under 18 years of age. MATERIALS AND METHODS: A retrospective and prospective study was done from July 2004 to June 2014. Malignant paranasal and orbital neoplasms were recorded including clinico - radiological and cytological data. Review of histopathological slides along with immunohistochemistry (IHC of selected cases were done. RESULTS: Total 69 cases were recorded over the ten year period as per our inclusion criteria. Out of these, 46 (67% patients presented with malignant paranasal neoplasm and 23 (33% with orbital mass. Most cases were found in the age group of 7 - 12 years, where females were preponderant. Rhabdomyosarcoma (RMS was the commonest tumor arising in paranasal as well as in orbital area (33%. IHC aided the confirmation of our diagnoses. CONCLUSION: Paranasal malignancy in the pediatric population often presents with non - specific symptoms, and high index of suspicion along with better diagnostic tools like computed tomography (CT scan is necessary for a timely diagnosis . IHC should be done in all malignant neoplasms of pediatric population to arrive at a proper diagnosis, to facilitate proper management to these patients

  9. Metastatic breast cancer in the eye and orbit, use three-dimensional conformal radiotherapy. Our first experience

    International Nuclear Information System (INIS)

    Correa Pablos, Tamara; Caceres Toledo, Maria

    2009-01-01

    The eye and orbit metastases are a significant clinical problem, both by the inability and the deterioration in the quality of life that occur. The most common malignant tumors in the eye and orbit is metastasis. Cancer breast cancer is the most common tumor metastatic to the eye and orbit in a 40% and 50% of cases according to different series. With the introduction of Three-Dimensional Conformal Radiotherapy (3D-CRT) in our hospital from In 2007 we were able to treat patients with cancer different regions with the technique (2D) was impossible because caused irreparable damage to surrounding healthy tissue in this way thanks to potential of 3D technology to shape the planning volume will ensure greater protection for critical organs. (Author)

  10. Pseudoanaplastic tumors of bone

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Won-Jong [Uijongbu St. Mary Hospital, The Catholic University of Korea, Department of Orthopaedic Surgery, Gyunggido, 480-821 (Korea); Mirra, Joseph M. [Orthopaedic Hospital, Orthopedic Oncology, Los Angeles, California (United States)

    2004-11-01

    To discuss the concept of pseudoanaplastic tumors of bone, which pathologically show hyperchromatism and marked pleomorphism with quite enlarged, pleomorphic nuclei, but with no to extremely rare, typical mitoses, and to propose guidelines for their diagnosis. From a database of 4,262 bone tumors covering from 1971 to 2001, 15 cases of pseudoanaplastic bone tumors (0.35% of total) were retrieved for clinical, radiographic and pathologic review. Postoperative follow-up after surgical treatment was at least 3 years and a maximum of 7 years. There were eight male and seven female patients. Their ages ranged from 10 to 64 years with average of 29.7 years. Pathologic diagnoses of pseudoanaplastic variants of benign bone tumors included: osteoblastoma (4 cases), giant cell tumor (4 cases), chondromyxoid fibroma (3 cases), fibrous dysplasia (2 cases), fibrous cortical defect (1 case) and aneurysmal bone cyst (1 case). Radiography of all cases showed features of a benign bone lesion. Six cases, one case each of osteoblastoma, fibrous dysplasia, aneurysmal bone cyst, chondromyxoid fibroma, giant cell tumor and osteoblastoma, were initially misdiagnosed as osteosarcoma. The remaining cases were referred for a second opinion to rule out sarcoma. Despite the presence of significant cytologic aberrations, none of our cases showed malignant behavior following simple curettage or removal of bony lesions. Our observation justifies the concept of pseudoanaplasia in some benign bone tumors as in benign soft tissue tumors, especially in their late evolutionary stage when bizarre cytologic alterations strongly mimic a sarcoma. (orig.)

  11. Radionuclide and thermographic diagnosis of head and neck tumors

    Energy Technology Data Exchange (ETDEWEB)

    Bogdasarov, Yu.B.; Lenskaya, O.P.; Polyakov, B.I.; Belkina, B.M. (Akademiya Meditsinskikh Nauk SSSR, Moscow. Onkologicheskij Nauchnyj Tsentr)

    1983-10-01

    Radionuclide and thermographic studies using /sup 67/Ga-citrate and /sup 111/In-bleomycin were performed in 129 patients with laryngeal cancer, chemodectoma of the neck, retinoblastoma, rhabdomyosarcoma of the orbital and facial soft tissues and cancer of the tongue. Elevated amounts of the radiopharmaceuticals were found in patients with tumors. In thermographic studies higher temperature activity corresponding to the tumor was noted. Radio-nuclide thermographic studies extend diagnostic opportunities for head and neck tumors.

  12. Radionuclide and thermographic diagnosis of head and neck tumors

    International Nuclear Information System (INIS)

    Bogdasarov, Yu.B.; Lenskaya, O.P.; Polyakov, B.I.; Belkina, B.M.

    1983-01-01

    Radionuclide and thermographic studies using 67 Ga-citrate and 111 In-bleomycin were performed in 129 patients with laryngeal cancer, chemodectoma of the neck, retinoblastoma, rhabdomyosarcoma of the orbital and facial soft tissues and cancer of the tongue. Elevated amounts of the radiopharmaceuticals were found in patients with tumors. In thermographic studies higher temperature activity corresponding to the tumor was noted. Radio-nuclide thermographic studies extend diagnostic opportunities for head and neck tumors

  13. Investigation of the imaging diagnosis on the ophthalmic orbital diseases

    International Nuclear Information System (INIS)

    Yoshizawa, Toshikazu

    1991-01-01

    Ultrasonographic examination, X-ray computerized tomography (CT) and magnetic resonance imaging (MRI) were performed on orbital diseases. Ultrasonographic examination was a simple, rapid and harmless noninvasive precedure as a diagnostic tool for evaluation of soft tissues. Echography was not more precise than X-ray CT and MRI scan in orbital diagnosis of the localization, size and well-defined outline of the lesion, relating to the peri- and retroorbital organs, however, was useful for screening study of an orbital lesion. B-mode of orbital tumors was effective for the ultrasonic diagnosis and classification according to four types; solid, cystic, angiomatous and infiltrative patterns. B-scan study of intraorbital inflammatory pseudo tumor could provide a differential diagnosis between inflammatory edema and an inflammatory mass lesion. Echographic pictures of dural arterio-venous fistula disclosed the vascular dilatation of superior ophthalmic vein and those of Basedow's disease with thickening of extraocular muscles. X-ray CT revealed intraorbital and intraocular disease, the globes and its immediate surrounding tissue (optic nerve, extraocular muscle, etc.) and bony orbital walls as the same slice of film. X-ray CT pictures of a coronal section, the contrast enhancement, calcification and destruction of the bone were helpful for diagnosis. However, the displays of disorders near the bone were ill-defined because of an artifact induced by high X-ray absorptive power of the bone. MRI was an equipment for superior contrast resolution, with provided a tomography of any section, without artifacts of the bone, and was the superior technique for displaying a vascular lesion. MRI of orbital disease was effective for reconstructing the spatial correlations between the lesion and its surounding tissues. MRI, however, provided no information of the skeleton, being not available for subjects with a magnetic substance. (author)

  14. Diffusion-weighted MR imaging in benign and malignant orbital masses

    International Nuclear Information System (INIS)

    Guo Jian; Wang Zhenchang; Xian Junfang; Niu Yantao; Zhao Bo; Yan Fei; Liu Zhonglin; Yang Bentao

    2007-01-01

    Objective: To analyse the characteristics of orbital benign and malignant masses on diffusion weighted imaging in combination with conventional MR imaging and evaluate the diagnostic value of apparent diffusion coefficient in distinguishing benign and malignant orbital lesions. Methods: Seventy- seven cases with orbital masses, including fifty-five benign lesions and twenty-two malignant tumors, who underwent conventional MRI and diffusion imaging scanning were studied with use of a 1.5 T magnetic resonance system. Quantitative ADC measurements of masses (ADCM) and of the white matter of contralateral temporal lobe (ADC w ) were made with two different b-values of 0 and 1000 s/mm 2 . The ADC ratio (ADCR) of the lesion to the control was calculated. The receiver operating characteristic curves(ROC) were constructed using various cut points of ADCM and ADCR for different parameters to differentiate between benign and malignant masses. The area under the ROC curve for each parameter was also calculated. Results: All cases were proved by histopathology. The mean ADCM and ADCR of benign orbital masses were (1.56 ± 0.75) x 10 -3 mm 2 /s and 1.85 ± 0.91, respectively. The mean ADCM and ADCR of malignant orbital masses were (1.09 ± 0.42) x 10 -3 mm 2 /s and 1.28 ± 0.53, respectively. There were significant difference both between ADCM and ADCR of benign and malignant masses (t=2.803, 2.735, P -3 mm 2 /s for ADC M of the tumor, the sensitivity, specificity and accuracy were 59.1%, 78.2% and 72.7%, respectively. And by using cut point of 1.24 for ADCR, the sensitivity, specificity and accuracy were 59.1%, 76.4%, 71.4%, respectively. Conclusion: Diffusion MR imaging and ADC value could provide additional information for conventional magnetic resonance imaging in distinguishing benign and malignant orbital masses. (authors)

  15. Dynamic and reduced-dynamic precise orbit determination of satellites in low earth orbits

    International Nuclear Information System (INIS)

    Swatschina, P.

    2009-01-01

    The precise positioning of satellites in Low Earth Orbits (LEO) has become a key technology for advanced space missions. Dedicated satellite missions, such as CHAMP, GRACE and GOCE, that aim to map the Earths gravity field and its variation over time with unprecedented accuracy, initiated the demand for highly precise orbit solutions of LEO satellites. Furthermore, a wide range of additional science opportunities opens up with the capability to generate accurate LEO orbits. For all considered satellite missions, the primary measurement system for navigation is a spaceborne GPS receiver. The goal of this thesis is to establish and implement methods for Precise Orbit Determination (POD) of LEO satellites using GPS. Striving for highest precision using yet efficient orbit generation strategies, the attained orbit solutions are aimed to be competitive with the most advanced solutions of other institutions. Dynamic and reduced-dynamic orbit models provide the basic concepts of this work. These orbit models are subsequently adjusted to the highly accurate GPS measurements. The GPS measurements are introduced at the zero difference level in the ionosphere free linear combination. Appropriate procedures for GPS data screening and editing are established to detect erroneous data and to employ measurements of good quality only. For the dynamic orbit model a sophisticated force model, especially designed for LEO satellites, has been developed. In order to overcome the limitations that are induced by the deficiencies of the purely dynamical model, two different types of empirical parameters are introduced into the force model. These reduced-dynamic orbit models allow for the generation of much longer orbital arcs while preserving the spacecraft dynamics to the most possible extent. The two methods for reduced-dynamic orbit modeling are instantaneous velocity changes (pulses) or piecewise constant accelerations. For both techniques highly efficient modeling algorithms are

  16. Treatment of giant cell tumor of bone: Current concepts

    OpenAIRE

    Puri Ajay; Agarwal Manish

    2007-01-01

    Giant cell tumor (GCT) of bone though one of the commonest bone tumors encountered by an orthopedic surgeon continues to intrigue treating surgeons. Usually benign, they are locally aggressive and may occasionally undergo malignant transformation. The surgeon needs to strike a balance during treatment between reducing the incidence of local recurrence while preserving maximal function. Differing opinions pertaining to the use of adjuvants for extension of curettage, the relative role of bone ...

  17. [Lung metastases: tumor reduction as an oncologic concept].

    Science.gov (United States)

    Dienemann, H; Hoffmann, H; Trainer, C; Muley, T

    1998-01-01

    The principle of surgery for lung metastases is the removal of all lesions in the lung that are either visible or detectable by palpation. This may be combined with complete dissection of all ipsilateral lymph nodes. Therefore, "tumor reduction" rather than "complete" or "radical resection" may be an adequate description of this surgical approach. Since the dissemination of--macroscopically not detectable--tumor cells represents the major mannerism of every metastatic disease, any local therapy appears to be a discrepancy. However, in most cases the rationale of surgery for lung metastases is the lack of effective systemic therapy and the low morbidity of surgery, along with up to 60% 5-year survival rates.

  18. Orbital metastasis: A rare manifestation of scapular bone osteosarcoma

    Directory of Open Access Journals (Sweden)

    Mohammad Taher Rajabi

    2014-01-01

    Full Text Available Purpose: To report a case of orbital metastasis from scapular bone osteosarcoma. Case Report: A 55-year-old man who was a known case of scapular bone osteosarcoma, was referred to our clinic with ocular symptoms including acute painful decreased vision, proptosis, conjunctival injection, and chemosis. He had undergone surgical excision of the original tumor and received systemic chemotherapy 4 months before. Imaging studies and incisional biopsy were performed for the orbital lesion, the histopathological examination confirmed the diagnosis of metastatic osteosarcoma. The patient was referred to the oncologist for palliative chemotherapy and further intervention; however, he deceased 2 months later due to sepsis in the context of immunosuppression. Conclusion: Metastatic involvement of the orbit due to osteosarcoma is a rare condition manifesting with orbital mass, pain, diplopia and ocular motility disturbance. Although there is no effective treatment, the combination of modalities such as chemotherapy, radiotherapy, and surgery may delay progression of the disease.

  19. MoonBEAM: A Beyond Earth-Orbit Gamma-Ray Burst Detector for Gravitational-Wave Astronomy

    Science.gov (United States)

    Hui, C. M.; Briggs, M. S.; Goldstein, A. M.; Jenke, P. A.; Kocevski, D.; Wilson-Hodge, C. A.

    2018-01-01

    Moon Burst Energetics All-sky Monitor (MoonBEAM) is a CubeSat concept of deploying gamma-ray detectors in cislunar space to improve localization precision for gamma-ray bursts by utilizing the light travel time difference between different orbits. We present here a gamma-ray SmallSat concept in Earth-Moon L3 halo orbit that is capable of rapid response and provide a timing baseline for localization improvement when partnered with an Earth-orbit instrument. Such an instrument would probe the extreme processes in cosmic collision of compact objects and facilitate multi-messenger time-domain astronomy to explore the end of stellar life cycles and black hole formations.

  20. Supra-orbital keyhole removal of anterior fossa and parasellar meningiomas Minicraniotomia supra-orbitária superciliar no tratamento de meningiomas na fossa craniana anterior e para-selares

    Directory of Open Access Journals (Sweden)

    Manoel Antonio de Paiva-Neto

    2010-06-01

    Full Text Available The improvement of surgical techniques as well as the introduction of new surgical instruments promoted the use of keyhole craniotomies in neurosurgery. We evaluated the technical aspects of the supra-orbital keyhole approach considering the indications, limitations, and complications of this approach to treat anterior cranial fossa and parasellar meningiomas. Twenty-four patients (21 females; mean age, 53±8.6 years operated on between 2002 and 2006 through a supra-orbital eyebrow approach were studied. Maximal tumor diameter ranged from 1.6 to 6 cm. Gross total resection was done in 20 (83.3%. All tumors were histologically benign. Two patients (8% experienced CSF rinorhea and another two patients suffered transitory diabetes insipidus (8%. One patient experienced transitory hemiparesis. There was one case of meningitis and one mortality. Follow-up ranged between 6 to 66 months (mean 31.5±20.1 months, with no recurrence. The supra-orbital keyhole craniotomy is a useful minimally invasive approach to treat selected anterior fossa and parasellar meningiomas.A evolução técnica e a introdução de instrumentais cirúrgicos mais delicados proporcionaram o uso de craniotomias menores no tratamento de patologias intracranianas. Avaliamos os aspectos técnicos da minicraniotomia supra-orbitária superciliar, considerando as indicações, limitações e complicações no tratamento de meningiomas na fossa craniana anterior e para-selares. Vinte e quarto pacientes (21 mulheres; idade média, 53±8,6 anos operados entre 2002 e 2006 foram estudados. O diâmetro tumoral máximo variou de 1,6 a 6 cm. Ressecção total foi obtida em 20 (83,3%. Todos os tumores eram histologicamente benignos. Dois pacientes (8% apresentaram fistula liquórica pós-operatória e outros dois diabetes insipido transitórioa (8%. Um paciente evoluiu com hemiparesia transitória. Houve um caso de meningite e um de evolução fatal. O seguimento variou de 6 a 66 meses (m

  1. MALT LYMPHOMA OF PALATE AND ORBIT

    Directory of Open Access Journals (Sweden)

    VIVIANA ANDREA CIFUENTES NAVAS

    2018-05-01

    Full Text Available TITLE: Malt palate and orbit lymphoma  Authors: CIFUENTES NAVAS-Viviana Andrea; MARTÍN PASCUAL- María Consolación; FERNÁNDEZ RODRÍGUEZ- Ana; ALONSO MESONERO- Marta; CHAVIANO GRAHJERA-Juan; MORAIS PÉREZ-Darío. INTRODUCTIONMALT-type lymphomas are lymphoid proliferations originated in the glandular epithelium of organs like the stomach, the salivary and lacrimal glands, and even, we can find lymphoid neoformations of non-epithelial localization, like in the orbital soft tissue. The lymphomas of the mucosal-associated lymphatic tissue (MALT represent only 0.2-0.3% and constitute a well-defined group of non-Hodgkin lymphomas of B origin. In the field of oral pathology, the salivary glands, tonsils and palate are mainly affected, it is more rare to find it in jugal mucosa.We present a rare case of MALT lymphoma with involvement of the palate and orbit. MATERIAL AND METHODS84-year-old patient with multiple pathologies. Derived from his primary care physician due to pharyngeal complaints of 4 to 5 days of evolution, associated with a painful palate lesion.He presented in right hemipaladar a tumoration of elastic consistency in submucosa, ulcerated in the center, with normal neck. Also left orbital tumor that limits the visual field. RESULTSCT and MRI of the neck report mass of 4x4 x2.5 cm in right hemipaladar, noninfiltrating concordant with possible lymphoma. The orbital MRI describes an intra and extra nasal left nasal lesion of 2.3x1.2x2 cm with characteristics consistent with lymphoma. CT of the neck: It demostrates a great mass of right hemipaladar, with lobulated contours and homogeneous enhancement of 40x32x25 mm, in intimate contact with medial pterygoid muscle, although there were no signs of infiltration, the rest of the edges being well delimited. Images characteristics look like a lymphoma, without being able to rule out other etiologies. MRI of the neck: It demostrates a diffuse thickening of right side of the soft palate that

  2. Integrated orbital servicing study follow-on. Volume 2: Technical analysis and system design

    Science.gov (United States)

    1978-01-01

    In-orbit service functional and physical requirements to support both low and high Earth orbit servicing/maintenance operations were defined, an optimum servicing system configuration was developed and mockups and early prototype hardware were fabricated to demonstrate and validate the concepts selected. Significant issues addressed include criteria for concept selection; representative mission equipment and approaches to their design for serviceability; significant serviceable spacecraft design aspects; servicer mechanism operation in one-g; approaches for the demonstration/simulation; and service mechanism structure design approach.

  3. Tumor immunotherapy : clinics of cytokines and monoclonal antibodies

    NARCIS (Netherlands)

    Nieken, Judith

    1999-01-01

    Tumor immunotherapy is defines as treatment that induces anti-tumor responses via the modulation of both cellular and homoral components of the host immune system. Its concept is based on hte assumption that tumor cells express unique protiens, so-calles tumor antigens, that can be identified as

  4. Anterior eye protection with orbital neoplasia

    International Nuclear Information System (INIS)

    Hancock, S.L.

    1986-01-01

    The administration of adequate doses of radiation to tumors involving the orbit and surrounding facial structures and sinuses is often complicated by the need to protect the sensitive ocular components, the lens and cornea. A technique has been devised that uses four photon beam fields and an optional electron field to treat the contents of both orbits and adjacent sinuses with effective, reproducible protection of cornea and lens. Essential features include: alignment of the corneal surfaces with the central plane of rotation of the treatment machine, use of a narrow eye block across the entire beam to shield a strip equal to the width of the cornea, positioned symmetrically across the central plane of rotation, fine alignment of the eye block with both corneal surfaces by altering pedestal angle, treatment with paired, wedged, anterior oblique fields to encompass desired orbital and sinus volumes with additional blocking placed as needed, and complementary, lateral strip fields using collimators set to eye block thickness to equalize dose in the posterior orbit shielded by the strip eye block. A similar anterior electron beam strip field may be added to boost the medial orbit and ethmoid regions covered by the eye block. Bite block head immobilization and easy, direct daily visualization of block position assures eye protection for each treatment and provides substantial reduction in dose to the cornea, lens and iris. Additional blocking may be incorporated to provide partial lacrimal and parotid sparing

  5. Development and verification of ground-based tele-robotics operations concept for Dextre

    Science.gov (United States)

    Aziz, Sarmad

    2013-05-01

    The Special Purpose Dextreous Manipulator (Dextre) is the latest addition to the on-orbit segment of the Mobile Servicing System (MSS); Canada's contribution to the International Space Station (ISS). Launched in March 2008, the advanced two-armed robot is designed to perform various ISS maintenance tasks on robotically compatible elements and on-orbit replaceable units using a wide variety of tools and interfaces. The addition of Dextre has increased the capabilities of the MSS, and has introduced significant complexity to ISS robotics operations. While the initial operations concept for Dextre was based on human-in-the-loop control by the on-orbit astronauts, the complexities of robotic maintenance and the associated costs of training and maintaining the operator skills required for Dextre operations demanded a reexamination of the old concepts. A new approach to ISS robotic maintenance was developed in order to utilize the capabilities of Dextre safely and efficiently, while at the same time reducing the costs of on-orbit operations. This paper will describe the development, validation, and on-orbit demonstration of the operations concept for ground-based tele-robotics control of Dextre. It will describe the evolution of the new concepts from the experience gained from the development and implementation of the ground control capability for the Space Station Remote Manipulator System; Canadarm 2. It will discuss the various technical challenges faced during the development effort, such as requirements for high positioning accuracy, force/moment sensing and accommodation, failure tolerance, complex tool operations, and the novel operational tools and techniques developed to overcome them. The paper will also describe the work performed to validate the new concepts on orbit and will discuss the results and lessons learned from the on-orbit checkout and commissioning of Dextre using the newly developed tele-robotics techniques and capabilities.

  6. Magnetic resonance imaging of intraorbital tumors

    International Nuclear Information System (INIS)

    Inoue, Tooru; Fukui, Masashi; Matsushima, Toshio; Fujii, Kiyotaka; Hasuo, Kanehiro

    1991-01-01

    Ten cases of histologically confirmed intraorbital tumors were studied with magnetic resonance imaging (MRI). Two meningiomas were nearly isointense on the T 1 -weighted image (T 1 WI) and the T 2 -weighted image (T 2 WI) relative on the cerebral cortex. The hemangiopericytoma, lacrimal gland tumor, optic glioma, and encephalocele were hypointense on the T 1 WI. The pseudotumor was hypoisointense on both the T 1 WI and the T 2 WI. The metastatic tumor (prostatic carcinoma) was hyperintense on both the T 1 WI and the T 2 WI. Gd-DTPA MRI was performed in five cases. The anatomical relationships between the tumor and the orbital tissue could be discriminated well by means of the coronal and sagittal views. MRI is thus found to be useful for the preoperative diagnosis of the intraorbital tumor and the selection of the surgical approach. (author)

  7. Radiotherapy of indolent orbital lymphomas. Two radiation concepts

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Laila; Stade, Robert; Rieber, Juliane; Debus, Juergen; Herfarth, Klaus [Universitaetsklinikum Heidelberg, Abteilung RadioOnkologie und Strahlentherapie, Heidelberg (Germany)

    2016-06-15

    The aim of this work was to retrospectively analyze efficacy, toxicity, and relapse rates of conventional (CRT) and low-dose radiotherapy (LDRT) in patients with indolent orbital lymphomas. From 1987-2014, 45 patients (median age 64 years) with 52 lesions of indolent orbital lymphomas were treated with CRT (median dose 36 Gy, range 26-46 Gy) and 7 patients (median age 75 years) with 8 lesions were treated with LDRT (2 fractions of 2.0 Gy). Median follow-up was 133 months (range 2-329 months) in the CRT group and 25 months (range 10-41 months) in the LDRT group. Overall response rates were 97.7 % (CRT) and 100 % (LDRT). The 2- and 5-year local progression-free survival (PFS) rates were 93.5 and 88.6 %, distant PFS 95.0 and 89.9 %, and overall survival 100 and 85.6 % after CRT. In the LDRT group, 2-year local PFS and overall survival remained 100 %, respectively, and distant PFS 68.6 %. Acute radiotherapy-related complications (grades 1-2) were detected in virtually all eyes treated with CRT. Cataracts developed in only patients who were irradiated with more than 34 Gy. LDRT was well tolerated with only mild acute and late complications. Primary radiotherapy of indolent orbital lymphomas is an effective treatment with high response rates and excellent local control in CRT and LDRT. In combination with close follow-up, LDRT may be an attractive alternative since re-irradiation even with conventional doses is still feasible. (orig.) [German] Ziel der Arbeit war die Analyse von Effektivitaet, Nebenwirkungen und Rezidivraten nach konventioneller (CRT) und Niedrigdosisbestrahlung (LDRT) indolenter Orbitalymphome. Retrospektiv evaluiert wurden 45 zwischen 1987 und 2014 behandelte Patienten (medianes Alter 64 Jahre) mit insgesamt 52 Laesionen indolenter Orbitalymphome, die mittels CRT (mediane Dosis 36 Gy, 26-46 Gy) therapiert wurden.; 7 Patienten mit insgesamt 8 Laesionen erhielten eine LDRT (2 x 2,0 Gy). Das mediane Follow-Up betrug 133 Monate (2-239 Monate) in der CRT

  8. Differentiation of orbital lymphoma and idiopathic orbital inflammatory pseudotumor: combined diagnostic value of conventional MRI and histogram analysis of ADC maps.

    Science.gov (United States)

    Ren, Jiliang; Yuan, Ying; Wu, Yingwei; Tao, Xiaofeng

    2018-05-02

    The overlap of morphological feature and mean ADC value restricted clinical application of MRI in the differential diagnosis of orbital lymphoma and idiopathic orbital inflammatory pseudotumor (IOIP). In this paper, we aimed to retrospectively evaluate the combined diagnostic value of conventional magnetic resonance imaging (MRI) and whole-tumor histogram analysis of apparent diffusion coefficient (ADC) maps in the differentiation of the two lesions. In total, 18 patients with orbital lymphoma and 22 patients with IOIP were included, who underwent both conventional MRI and diffusion weighted imaging before treatment. Conventional MRI features and histogram parameters derived from ADC maps, including mean ADC (ADC mean ), median ADC (ADC median ), skewness, kurtosis, 10th, 25th, 75th and 90th percentiles of ADC (ADC 10 , ADC 25 , ADC 75 , ADC 90 ) were evaluated and compared between orbital lymphoma and IOIP. Multivariate logistic regression analysis was used to identify the most valuable variables for discriminating. Differential model was built upon the selected variables and receiver operating characteristic (ROC) analysis was also performed to determine the differential ability of the model. Multivariate logistic regression showed ADC 10 (P = 0.023) and involvement of orbit preseptal space (P = 0.029) were the most promising indexes in the discrimination of orbital lymphoma and IOIP. The logistic model defined by ADC 10 and involvement of orbit preseptal space was built, which achieved an AUC of 0.939, with sensitivity of 77.30% and specificity of 94.40%. Conventional MRI feature of involvement of orbit preseptal space and ADC histogram parameter of ADC 10 are valuable in differential diagnosis of orbital lymphoma and IOIP.

  9. Clinical application of TDF concept

    International Nuclear Information System (INIS)

    Tsujii, Hirohiko; Kamada, Tadashi; Irie, Goro

    1987-01-01

    Our clinical data has demonstrated that the NSD-TDF concept is valid in evaluation of radiation response in terms of predicting the total dose required to produce normal-tissue injury and local tumor control. However, in certain type of tumors such as maxillary cancers and esophagus cancers, the probability of tumor control was reversely related to the TDF values at about 120 to 130. This raises a potential possibility of ''supralethal phenomenon'' that is defined as a concomitant presence of recurrent tumor and radiation-induced necrotic tissue after high-dose irradiation. There has been accumulated data suggesting that the exponents of overall time (0.11) in NSD formula might yield a wrong shape of dose-response curve, resulting in a failure in prediction of late damage. However, it is considered that the NSD-TDF concept is still a practical model as far as it is used as a clue for calculation of alternative fractionation in daily radiotherapy. (author)

  10. Titan Orbiter with Aerorover Mission (TOAM)

    Science.gov (United States)

    Sittler, Edward C.; Cooper, J. F.; Mahaffey, P.; Esper, J.; Fairbrother, D.; Farley, R.; Pitman, J.; Kojiro, D. R.; TOAM Team

    2006-12-01

    We propose to develop a new mission to Titan called Titan Orbiter with Aerorover Mission (TOAM). This mission is motivated by the recent discoveries of Titan, its atmosphere and its surface by the Huygens Probe, and a combination of in situ, remote sensing and radar mapping measurements of Titan by the Cassini orbiter. Titan is a body for which Astrobiology (i.e., prebiotic chemistry) will be the primary science goal of any future missions to it. TOAM is planned to use an orbiter and balloon technology (i.e., aerorover). Aerobraking will be used to put payload into orbit around Titan. The Aerorover will probably use a hot air balloon concept using the waste heat from the MMRTG 500 watts. Orbiter support for the Aerorover is unique to our approach for Titan. Our strategy to use an orbiter is contrary to some studies using just a single probe with balloon. Autonomous operation and navigation of the Aerorover around Titan will be required, which will include descent near to the surface to collect surface samples for analysis (i.e., touch and go technique). The orbiter can provide both relay station and GPS roles for the Aerorover. The Aerorover will have all the instruments needed to sample Titan’s atmosphere, surface, possible methane lakes-rivers, use multi-spectral imagers for surface reconnaissance; to take close up surface images; take core samples and deploy seismometers during landing phase. Both active and passive broadband remote sensing techniques will be used for surface topography, winds and composition measurements.

  11. . Modern concepts on carcinogenesis: the value of insufficiency of malignant cell elimination mechanisms in the tumor progression in case of neoplasia at different localizations

    Directory of Open Access Journals (Sweden)

    Chesnokova N.P.

    2016-03-01

    Full Text Available The article presents the review of contemporary concepts of tumor induction mechanisms applicable for neoplastic transformation, promotion and proliferation. The paper also contains an in-depth analysis of results of authors' own observations and study of immunological protection mechanisms of a significant number of patients diagnosed with oncopathologies of mammary and thyroid glands as well as adenocarcinoma of ascending colon. We have established common development patterns of T-cell and B-cell immunodeficiencies that are not influenced by location and proliferation of neoplastic tumors; the progress of such immunodeficincies, however, depends on regional metastasis development. Thus, we can conclude that insufficiency of immunological defense mechanisms leading to disruption of maligned cell elimination process is the primary pathogenic factor for metastatic tumor development.

  12. Investigation of Orbital Debris: Mitigation, Removal, and Modeling the Debris Population

    Science.gov (United States)

    Slotten, Joel

    The population of objects in orbit around Earth has grown since the late 1950s. Today there are over 21,000 objects over 10 cm in length in orbit, and an estimated 500,000 more between 1 and 10 cm. Only a small fraction of these objects are operational satellites. The rest are debris: old derelict spacecraft or rocket bodies, fragments created as the result of explosions or collisions, discarded objects, slag from solid rockets, or even flaked off paint. Traveling at up to 7 km/s, a collision with even a 1 cm piece of debris could severely damage or destroy a satellite. This dissertation examines three aspects of orbital debris. First, the concept of a self-consuming satellite is explored. This nanosatellite would use its own external structure as propellant to execute a deorbit maneuver at the end of its operational life, thus allowing it to meet current debris mitigation standards. Results from lab experiments examining potential materials for this concept have shown favorable results. Second, Particle in Cell techniques are modified and used to model the plasma plume from a micro-cathode arc thruster. This model is then applied to the concept of an ion beam shepherd satellite. This satellite would use its plasma plume to deorbit another derelict satellite. Results from these simulations indicate the micro-cathode arc thruster could potentially deorbit a derelict CubeSat in a matter of a few weeks. Finally, the orbital debris population at geosynchronous orbit is examined, focusing on variations in the density of the population as a function of longitude. New insights are revealed demonstrating that the variation in population density is slightly less than previously reported.

  13. The habitable zone and extreme planetary orbits.

    Science.gov (United States)

    Kane, Stephen R; Gelino, Dawn M

    2012-10-01

    The habitable zone for a given star describes the range of circumstellar distances from the star within which a planet could have liquid water on its surface, which depends upon the stellar properties. Here we describe the development of the habitable zone concept, its application to our own solar system, and its subsequent application to exoplanetary systems. We further apply this to planets in extreme eccentric orbits and show how they may still retain life-bearing properties depending upon the percentage of the total orbit which is spent within the habitable zone. Key Words: Extrasolar planets-Habitable zone-Astrobiology.

  14. Man-Made Debris In and From Lunar Orbit

    Science.gov (United States)

    Johnson, Nicholas L.; McKay, Gordon A. (Technical Monitor)

    1999-01-01

    During 1966-1976, as part of the first phase of lunar exploration, 29 manned and robotic missions placed more than 40 objects into lunar orbit. Whereas several vehicles later successfully landed on the Moon and/or returned to Earth, others were either abandoned in orbit or intentionally sent to their destruction on the lunar surface. The former now constitute a small population of lunar orbital debris; the latter, including four Lunar Orbiters and four Lunar Module ascent stages, have contributed to nearly 50 lunar sites of man's refuse. Other lunar satellites are known or suspected of having fallen from orbit. Unlike Earth satellite orbital decays and deorbits, lunar satellites impact the lunar surface unscathed by atmospheric burning or melting. Fragmentations of lunar satellites, which would produce clouds of numerous orbital debris, have not yet been detected. The return to lunar orbit in the 1990's by the Hagoromo, Hiten, Clementine, and Lunar Prospector spacecraft and plans for increased lunar exploration early in the 21st century, raise questions of how best to minimize and to dispose of lunar orbital debris. Some of the lessons learned from more than 40 years of Earth orbit exploitation can be applied to the lunar orbital environment. For the near-term, perhaps the most important of these is postmission passivation. Unique solutions, e.g., lunar equatorial dumps, may also prove attractive. However, as with Earth satellites, debris mitigation measures are most effectively adopted early in the concept and design phase, and prevention is less costly than remediation.

  15. Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    Science.gov (United States)

    Wagner, Maximilian E H; Gellrich, Nils-Claudius; Friese, Karl-Ingo; Becker, Matthias; Wolter, Franz-Erich; Lichtenstein, Juergen T; Stoetzer, Marcus; Rana, Majeed; Essig, Harald

    2016-01-01

    Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior tissue representation, although CBCT has the benefit of greater availability and lower patient radiation exposure. Therefore, a model-based segmentation technique is presented as a new method for measuring orbital volume and compared to alternative techniques. Both eyes from thirty subjects with no known orbital pathology who had undergone CBCT as a part of routine care were evaluated (n = 60 eyes). Orbital volume was measured with manual, atlas-based, and model-based segmentation methods. Volume measurements, volume determination time, and usability were compared between the three methods. Differences in means were tested for statistical significance using two-tailed Student's t tests. Neither atlas-based (26.63 ± 3.15 mm(3)) nor model-based (26.87 ± 2.99 mm(3)) measurements were significantly different from manual volume measurements (26.65 ± 4.0 mm(3)). However, the time required to determine orbital volume was significantly longer for manual measurements (10.24 ± 1.21 min) than for atlas-based (6.96 ± 2.62 min, p < 0.001) or model-based (5.73 ± 1.12 min, p < 0.001) measurements. All three orbital volume measurement methods examined can accurately measure orbital volume, although atlas-based and model-based methods seem to be more user-friendly and less time-consuming. The new model-based technique achieves fully automated segmentation results, whereas all atlas-based segmentations at least required manipulations to the anterior closing. Additionally, model-based segmentation can provide reliable orbital volume measurements when CT image quality is poor.

  16. Magnetic resonance imaging of intraorbital tumors

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Tooru; Fukui, Masashi; Matsushima, Toshio; Fujii, Kiyotaka; Hasuo, Kanehiro (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1991-12-01

    Ten cases of histologically confirmed intraorbital tumors were studied with magnetic resonance imaging (MRI). Two meningiomas were nearly isointense on the T[sub 1]-weighted image (T[sub 1]WI) and the T[sub 2]-weighted image (T[sub 2]WI) relative on the cerebral cortex. The hemangiopericytoma, lacrimal gland tumor, optic glioma, and encephalocele were hypointense on the T[sub 1]WI. The pseudotumor was hypoisointense on both the T[sub 1]WI and the T[sub 2]WI. The metastatic tumor (prostatic carcinoma) was hyperintense on both the T[sub 1]WI and the T[sub 2]WI. Gd-DTPA MRI was performed in five cases. The anatomical relationships between the tumor and the orbital tissue could be discriminated well by means of the coronal and sagittal views. MRI is thus found to be useful for the preoperative diagnosis of the intraorbital tumor and the selection of the surgical approach. (author).

  17. Orbital involvement by non-Hodgkin lymphoma NK T cells.

    Science.gov (United States)

    Hervás-Ontiveros, A; España-Gregori, E; Hernández-Martínez, P; Vera-Sempere, F J; Díaz-Llopis, M

    2014-11-01

    The case is presented of 37 year-old male with a history of nasal obstruction with right rhinorrhea, headache, hearing loss and right exophthalmos of 4 months progression. The MRI revealed that the ethmoidal and maxillary sinuses contained inflammatory tissue extending into the orbital region. The biopsy confirmed a non-Hodgkin lymphoma of natural killer (NK) T cells. Non-Hodgkin's T NK lymphoma is a rare tumor in the orbital area that requires an early detection and multi-disciplinary care to ensure appropriate monitoring and treatment. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  18. 3D Printing of Molecular Models with Calculated Geometries and p Orbital Isosurfaces

    Science.gov (United States)

    Carroll, Felix A.; Blauch, David N.

    2017-01-01

    3D printing was used to prepare models of the calculated geometries of unsaturated organic structures. Incorporation of p orbital isosurfaces into the models enables students in introductory organic chemistry courses to have hands-on experience with the concept of orbital alignment in strained and unstrained p systems.

  19. Space Shuttle OMS engine valve technology. [Orbital Maneuvering System

    Science.gov (United States)

    Wichmann, H.

    1974-01-01

    Valve technology program to determine shutoff valve concepts suitable for the Orbital Maneuvering System (OMS) engine of the Space Shuttle. The tradeoff studies selected the electric torque motor operated dual poppet and ball valves as the most desirable valve concepts for the OMS Engine Shutoff Valve. A prototype of one of these concepts was built and subjected to a design verification program. A number of unique features were designed to include the required contamination insensitivity, operating fluid compatibility, decontamination capability, minimum maintenance requirement and long service life capability.

  20. Relative Stabilities and Reactivities of Isolated Versus Conjugated Alkenes: Reconciliation Via a Molecular Orbital Approach

    Science.gov (United States)

    Sotiriou-Leventis, Chariklia; Hanna, Samir B.; Leventis, Nicholas

    1996-04-01

    The well-accepted practice of generating a pair of molecular orbitals, one of lower energy and another of higher energy than the original pair of overlapping atomic orbitals, and the concept of a particle in a one-dimensional box are implemented in a simplified, nonmathematical method that explains the relative stabilities and reactivities of alkenes with conjugated versus isolated double bonds. In this method, Huckel-type MO's of higher polyenes are constructed by energy rules of linear combination of atomic orbitals. One additional rule is obeyed: bonding molecular orbitals overlap only with bonding molecular orbitals, and antibonding molecular orbitals overlap only with antibonding molecular orbitals.

  1. Efficacy of Vismodegib (Erivedge) for Basal Cell Carcinoma Involving the Orbit and Periocular Area.

    Science.gov (United States)

    Demirci, Hakan; Worden, Francis; Nelson, Christine C; Elner, Victor M; Kahana, Alon

    2015-01-01

    Evaluate the effectiveness of vismodegib in the management of basal cell carcinoma with orbital extension and/or extensive periocular involvement. Retrospective chart review of 6 consecutive patients with biopsy-proven orbital basal cell carcinoma and 2 additional patients with extensive periocular basal cell carcinoma who were treated with oral vismodegib (150 mg/day) was performed. Basal cell carcinoma extended in the orbit in 6 of 8 patients (involving orbital bones in 1 patient), and 2 of 8 patients had extensive periocular involvement (1 with basal cell nevus syndrome). Vismodegib therapy was the only treatment in 6 patients, off-label neoadjuvant in 1 patient, and adjuvant treatment in 1 patient. Orbital tumors in all 4 patients who received vismodegib as sole treatment showed partial response with a mean 83% shrinkage in tumor size after a median of 7 months of therapy. In the 2 patients receiving vismodegib as neoadjuvant or adjuvant therapies, there was complete response after a median of 7 months of therapy and no evidence of clinical recurrence after discontinuing therapy for a median of 15 months. The 2 patients with extensive periocular involvement experienced complete clinical response after a median 14 months of treatment. During treatment, the most common side effects were muscle spasm (75%) followed by alopecia (50%), dysgeusia (25%), dysosmia, and episodes of diarrhea and constipation (13%). Basal cell carcinoma with orbital extension and extensive periocular involvement responds to vismodegib therapy. The long-term prognosis remains unknown, and additional prospective studies are indicated.

  2. Case of false positive scanning observed after radiation therapy for orbital tumor

    Energy Technology Data Exchange (ETDEWEB)

    Ohara, H [Gifu Prefectural Tajimi Hospital (Japan); Nakamura, K; Maeda, S; Watanabe, R; Miyajima, T

    1978-12-01

    A report was made of 56-year-old female patient of abducensparesis. In the early stage the cause remained undetermined with nothing abnormal noted in scintigraphy. Diplopia disappeared once, but right, exophalmus relapsed. In gammaencepharography, a hot spot was noted in the orbita, sinus ethmoidalis and sirus sphenoidalis. In an operation, squamous cell carcinoma was removed and radiation therapy was performed (total dose of 3520 r) and, three months later a scintigraphy disclosed a high spot of /sup 203/Hg uptake ratio in the right orbita and its lower portions. The biopsy of these portions disclosed a necrotic tissue instead of a tumor. In scintigraphy after radiation therapy against the tumor, it was reported that a positive scintigraphy was present because of the vascular trouble of said portions, although the tumor had disappeared. Attention should be given as well as an opinion of high density together with the examination by CT, especially as to enhancement.

  3. [Orbital alveolar rhabdomyosarcoma masked by ethmoid sinusitis in a 25-year-old].

    Science.gov (United States)

    Sanz-Marco, E; España, E; Alamar, A; Pérez-Rojas, J; López-Prats, M J; Díaz-Llopis, M

    2014-05-01

    A 25-year-old woman with right subacute sinusitis, complained about discomfort in her right eye. Clinical manifestations and computed tomography were suggestive of sub-periosteal orbital ethmoid wall abscess, for which the patient underwent urgent drainage. A solid tumor was found, with a positive biopsy for alveolar rhabdomyosarcoma. Complete remission and resolution of orbital symptoms were achieved with chemotherapy and radiation therapy. Alveolar orbital rhabdomyosarcoma in adults is uncommon. Rhabdomyosarcoma has a high risk of spreading. It can simulate a sinusitis, as in our patient, early diagnosis and early treatment being especially important in these patients. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  4. Trajectory Options for a Potential Mars Mission Combining Orbiting Science, Relay and a Sample Return Rendezvous Demonstration

    Science.gov (United States)

    Guinn, Joseph R.; Kerridge, Stuart J.; Wilson, Roby S.

    2012-01-01

    Mars sample return is a major scientific goal of the 2011 US National Research Council Decadal Survey for Planetary Science. Toward achievement of this goal, recent architecture studies have focused on several mission concept options for the 2018/2020 Mars launch opportunities. Mars orbiters play multiple roles in these architectures such as: relay, landing site identification/selection/certification, collection of on-going or new measurements to fill knowledge gaps, and in-orbit collection and transportation of samples from Mars to Earth. This paper reviews orbiter concepts that combine these roles and describes a novel family of relay orbits optimized for surface operations support. Additionally, these roles provide an intersection of objectives for long term NASA science, human exploration, technology development and international collaboration.

  5. Global communication using a constellation of low earth meridian orbits

    Science.gov (United States)

    Oli, P. V. S.; Nagarajan, N.; Rayan, H. R.

    1993-07-01

    The concept of 'meridian orbits' is briefly reviewed. It is shown that, if a satellite in the meridian orbit makes an odd number of revolutions per day, then the satellite passes over the same set of meridians twice a day. Satellites in such orbits pass over the same portion of the sky twice a day and every day. This enables a user to adopt a programmed mode of tracking, thereby avoiding a computational facility for orbit prediction, look angle generation, and auto tracking. A constellation of 38 or more satellites placed in a 1200 km altitude circular orbit is favorable for global communications due to various factors. It is shown that appropriate phasing in right ascension of the ascending node and mean anomaly results in a constellation, wherein each satellite appears over the user's horizon one satellite after another. Visibility and coverage plots are provided to verify the continuous coverage.

  6. SEP Mission Design Space for Mars Orbiters

    Science.gov (United States)

    Woolley, Ryan C.; Nicholas, Austin K.

    2015-01-01

    The advancement of solar-electric propulsion (SEP) technologies and larger, light-weight solar arrays offer a tremendous advantage to Mars orbiters in terms of both mass and timeline flexibility. These advantages are multiplied for round-trip orbiters (e.g. potential Mars sample return) where a large total Delta V would be required. In this paper we investigate the mission design characteristics of mission concepts utilizing various combinations and types of SEP thrusters, solar arrays, launch vehicles, launch dates, arrival dates, etc. SEP allows for greater than 50% more mass delivered and launch windows of months to years. We also present the SEP analog to the ballistic Porkchop plot - the "Bacon" plot.

  7. Radiation therapy of a metastatic tumour of the orbit caused by prostatic carcinoma

    International Nuclear Information System (INIS)

    Daniel, F.; Langmann, G.; Faulborn, J.; Poschauko, J.

    1994-01-01

    We report a case of metastatic carcinoma to the apex of the orbit in a 66-year old patient. Orbital metastasis occurred while the patient suffered from another metastatic activity especially in his bony structures. The orbital tumour caused rapid visual impairment because of compression of the optic nerve. The metastasis was treated by radiation therapy. With CT-scan, electrophysiological examination, visual field examination, and visual function we demonstrate the regression of the tumour. One year after therapy the tumor was no longer detectable. Visual function had recovered and visual fields were normally. Radiation therapy prolonged high quality life for our patient due to preservation of visual function. (authors)

  8. Frozen orbit realization using LQR analogy

    Science.gov (United States)

    Nagarajan, N.; Rayan, H. Reno

    In the case of remote sensing orbits, the Frozen Orbit concept minimizes altitude variations over a given region using passive means. This is achieved by establishing the mean eccentricity vector at the orbital poles i.e., by fixing the mean argument of perigee at 90 deg with an appropriate eccentricity to balance the perturbations due to zonal harmonics J2 and J3 of the Earth's potential. Eccentricity vector is a vector whose magnitude is the eccentricity and direction is the argument of perigee. The launcher dispersions result in an eccentricity vector which is away from the frozen orbit values. The objective is then to formulate an orbit maneuver strategy to optimize the fuel required to achieve the frozen orbit in the presence of visibility and impulse constraints. It is shown that the motion of the eccentricity vector around the frozen perigee can be approximated as a circle. Combining the circular motion of the eccentricity vector around the frozen point and the maneuver equation, the following discrete equation is obtained. X(k+1) = AX(k) + Bu(k), where X is the state (i.e. eccentricity vector components), A the state transition matrix, u the scalar control force (i.e. dV in this case) and B the control matrix which transforms dV into eccentricity vector change. Based on this, it is shown that the problem of optimizing the fuel can be treated as a Linear Quadratic Regulator (LQR) problem in which the maneuver can be solved by using control system design tools like MATLAB by deriving an analogy LQR design.

  9. Melanotic neuroectodermal primitive tumor of infancy. Report of a case

    International Nuclear Information System (INIS)

    Suarez Mattos, Amaranto; Restrepo, Ligia; Penagos, Pedro; Rubio, Alba

    2002-01-01

    The melanotic neuroectodermal tumor of infancy is a rare neoplasia originated from the neural crest, it is frequently located in orofacial bones, although other localizations have been reported; occurs predominantly in infants. The behavior is benign and the treatment consists mainly in complete surgical resection. A four-month old male with an orbital tumor and intracranial extension, managed surgically with favorable outcome, is described

  10. CCCT - NCTN Steering Committees - Pediatric and Adolescent Tumor

    Science.gov (United States)

    The Pediatric and Adolescent Solid Tumor Steering Committee addresses the design, prioritization and evaluation of concepts for large phase 2 and phase 3 clinical trials in extracranial solid tumors of children and youth.

  11. Alveolar soft-part sarcoma of the orbit: a clinicopathologic analysis of seventeen cases and a review of the literature.

    Science.gov (United States)

    Font, R L; Jurco, S; Zimmerman, L E

    1982-06-01

    This is a clinicopathologic study of 17 cases of alveolar soft-part sarcoma of the orbit. The mean age of patients was 23 and the median was 18 (range, 11 months to 69 years); 13 patients (76.5 per cent) were women and four were men (ratio, 3.25:1). The right and left orbits were equally involved (eight patients each), and in one the laterality was not specified. Histologically, the tumors had a distinctive organoid pattern outlined by thin-walled capillaries and were composed of nests of large polyhedral cells with abundant, finely granular, acidophilic cytoplasm. Approximately two thirds of the tumors had diagnostic PAS-positive diastase-resistant crystalline structures. Histologically, the differential diagnosis included nonchromaffin paraganglioma, granular cell tumor, metastatic renal cell carcinoma, vascular tumor, alveolar rhabdomyosarcoma, and amelanotic malignant melanoma. Electron microscopic studies of one tumor disclosed mitochondria with abnormal cristae, increased amounts of glycogen, and cytoplasmic crystalline structures with a periodicity of 8 to 10 nm. Smaller membrane-bound electron-dense granules appeared to be precursors of the crystals. Follow-up studies showed that eight patients were alive and well (median follow-up period, 11.4 years). Six of the eight patients at the time of diagnosis were 20 years of age or younger. A ninth patient was alive and well 13 years after excision of the orbital mass and four years after bilateral thoracotomy with resection of nine pulmonary nodules. Two patients died as a result of metastatic disease, one 14 years and the other 21 years after initial orbital surgery. Two patients died of other causes, one of whom had pulmonary metastases at autopsy. The follow-up period on two recent cases was less than three years, and two patients were lost to follow-up. The disease pursued an indolent clinical course. Surgery offers the best chance to control the disease.

  12. High resolution earth observation from geostationary orbit by optical aperture synthesys

    Science.gov (United States)

    Mesrine, M.; Thomas, E.; Garin, S.; Blanc, P.; Alis, C.; Cassaing, F.; Laubier, D.

    2017-11-01

    In this paper, we describe Optical Aperture Synthesis (OAS) imaging instrument concepts studied by Alcatel Alenia Space under a CNES R&T contract in term of technical feasibility. First, the methodology to select the aperture configuration is proposed, based on the definition and quantification of image quality criteria adapted to an OAS instrument for direct imaging of extended objects. The following section presents, for each interferometer type (Michelson and Fizeau), the corresponding optical configurations compatible with a large field of view from GEO orbit. These optical concepts take into account the constraints imposed by the foreseen resolution and the implementation of the co-phasing functions. The fourth section is dedicated to the analysis of the co-phasing methodologies, from the configuration deployment to the fine stabilization during observation. Finally, we present a trade-off analysis allowing to select the concept wrt mission specification and constraints related to instrument accommodation under launcher shroud and in-orbit deployment.

  13. Using Mouse Mammary Tumor Cells to Teach Core Biology Concepts: A Simple Lab Module.

    Science.gov (United States)

    McIlrath, Victoria; Trye, Alice; Aguanno, Ann

    2015-06-18

    Undergraduate biology students are required to learn, understand and apply a variety of cellular and molecular biology concepts and techniques in preparation for biomedical, graduate and professional programs or careers in science. To address this, a simple laboratory module was devised to teach the concepts of cell division, cellular communication and cancer through the application of animal cell culture techniques. Here the mouse mammary tumor (MMT) cell line is used to model for breast cancer. Students learn to grow and characterize these animal cells in culture and test the effects of traditional and non-traditional chemotherapy agents on cell proliferation. Specifically, students determine the optimal cell concentration for plating and growing cells, learn how to prepare and dilute drug solutions, identify the best dosage and treatment time course of the antiproliferative agents, and ascertain the rate of cell death in response to various treatments. The module employs both a standard cell counting technique using a hemocytometer and a novel cell counting method using microscopy software. The experimental procedure lends to open-ended inquiry as students can modify critical steps of the protocol, including testing homeopathic agents and over-the-counter drugs. In short, this lab module requires students to use the scientific process to apply their knowledge of the cell cycle, cellular signaling pathways, cancer and modes of treatment, all while developing an array of laboratory skills including cell culture and analysis of experimental data not routinely taught in the undergraduate classroom.

  14. Orbital Propagation of Momentum Exchange Tether Systems

    Science.gov (United States)

    Westerhoff, John

    2002-01-01

    An advanced concept in in-space transportation currently being studied is the Momentum-Exchange/Electrodynamic Reboost Tether System (MXER). The system acts as a large momentum wheel, imparting a Av to a payload in low earth orbit (LEO) at the expense of its own orbital energy. After throwing a payload, the system reboosts itself using an electrodynamic tether to push against Earth's magnetic field and brings itself back up to an operational orbit to prepare for the next payload. The ability to reboost itself allows for continued reuse of the system without the expenditure of propellants. Considering the cost of lifting propellant from the ,ground to LEO to do the same Av boost at $10000 per pound, the system cuts the launch cost of the payload dramatically, and subsequently, the MXER system pays for itself after a small number of missions.1 One of the technical hurdles to be overcome with the MXER concept is the rendezvous maneuver. The rendezvous window for the capture of the payload is on the order of a few seconds, as opposed to traditional docking maneuvers, which can take as long ets necessary to complete a precise docking. The payload, therefore, must be able to match its orbit to meet up with the capture device on the end of the tether at a specific time and location in the future. In order to be able to determine that location, the MXER system must be numerically propagated forward in time to predict where the capture device will be at that instant. It should be kept in mind that the propagation computation must be done faster than real-time. This study focuses on the efforts to find and/or build the tools necessary to numerically propagate the motion of the MXER system as accurately as possible.

  15. Orbital lymphoma associated with Graves’ disease: A case report

    Directory of Open Access Journals (Sweden)

    Hajduković Zoran

    2014-01-01

    Full Text Available Introduction. The presence of bilateral exophthalmos and palpebral, periorbital edema associated with hyperthyroidism is most often considered as an initial sign of Graves’ ophthalmopathy. However, in up to 20% of cases, Graves’ ophthalmopathy might precede the occurrence of hyperthyroidism, which is very important to be considered in the differential diagnosis, especially if it is stated as unilateral. Among other less common causes of non-thyroid-related orbitopathy, orbital lymphoma represents rare conditions. We presented of a patient with Graves’ disease, initially manifested as bilateral orbitopathy and progressive unilateral exophthalmos caused by the marginal zone B-cell non-Hodgkin lymphoma of the orbit. Case report. A 64-yearold man with the 3-year history of bilateral Graves’ orbitopathy and hyperthyroidism underwent the left orbital decompression surgery due to the predominantly left, unilateral worsening of exophthalmos resistant to the previously applied glucocorticoid therapy. A year after the surgical treatment, a substantial exophthalmos of the left eye was again observed, signifying that other non-thyroid pathology could be involved. Orbital ultrasound was suggestive of primary orbital lymphoma, what was confirmed by orbital CT scan and the biopsy of the tumor tissue. Detailed examinations indicated that the marginal zone B-cell non-Hodgkin lymphoma extended to IV - B-b CS, IPI 3 (bone marrow infiltration: m+ orbit+. Upon the completion of the polychemiotherapy and the radiation treatment, a complete remission of the disease was achieved. Conclusion. Even when elements clearly indicate the presence of thyroid-related ophthalmopathy, disease deteriorating should raise a suspicion and always lead to imaging procedures to exclude malignancy.

  16. Teratoma cístico da órbita: estudo clínico patológico: relato de caso Cystic orbital teratoma: clinicopathologic study: case report

    Directory of Open Access Journals (Sweden)

    Iluska Fagundes Andrade

    2008-06-01

    Full Text Available Apresentamos um caso de tumor orbitário congênito de grande tamanho, ocorrendo em criança recém-nascida. A paciente foi submetida a exenteração da órbita e o diagnóstico anatomopatológico foi de teratoma cístico. Os aspectos clínico-patológicos desta rara doença são comentados.We report on a case of an congenital orbital tumor of impressive size, occurring in a newborn. The patient underwent orbital exenteration with a histopathologic diagnosis of cystic teratoma. The clinicopathological aspects of such a rare disease are commented.

  17. Brown tumor mimicking maxillary sinus mucocele as the first manifestation of primary hyperparathyroidism

    DEFF Research Database (Denmark)

    Guldfred, Liviu-Adelin; Daugaard, Søren; von Buchwald, Christian

    2012-01-01

    We describe the first case of brown tumor mimicking a maxillary sinus mucocele as the first manifestation of the patient's primary hyperparathyroidism. A 34-year old woman presented with a 14 days history of elevation of the right orbit, retrobulbar pain and cheek anesthesia. The CT and MR evalua...... either giant cell granuloma or brown tumor. The finding of hyperparathyroidism confirmed the diagnosis of brown tumor. To our knowledge, this is the first report of cystic brown tumor mimicking a mucocele of the maxillary sinus....

  18. Space Elevator Concept Considered a Reality

    Science.gov (United States)

    2000-01-01

    The `once upon a time' science fiction concept of a space elevator has been envisioned and studied as a real mass transportation system in the latter part of the 21st century. David Smitherman of NASA's Marshall Space Flight Center's Advanced Projects Office has compiled plans for such an elevator. The space elevator concept is a structure extending from the surface of the Earth to geostationary Earth orbit (GEO) at 35,786 km in altitude. The tower would be approximately 50 km tall with a cable tethered to the top. Its center mass would be at GEO such that the entire structure orbits the Earth in sync with the Earth's rotation maintaining a stationary position over its base attachment at the equator. Electromagnetic vehicles traveling along the cable could serve as a mass transportation system for transporting people, payloads, and power between space and Earth. This illustration by artist Pat Rawling shows the concept of a space elevator as viewed from the geostationary transfer station looking down the length of the elevator towards the Earth.

  19. Chaos and nonlinear dynamics of single-particle orbits in a magnetotaillike magnetic field

    Science.gov (United States)

    Chen, J.; Palmadesso, P. J.

    1986-01-01

    The properties of charged-particle motion in Hamiltonian dynamics are studied in a magnetotaillike magnetic field configuration. It is shown by numerical integration of the equation of motion that the system is generally nonintegrable and that the particle motion can be classified into three distinct types of orbits: bounded integrable orbits, unbounded stochastic orbits, and unbounded transient orbits. It is also shown that different regions of the phase space exhibit qualitatively different responses to external influences. The concept of 'differential memory' in single-particle distributions is proposed. Physical implications for the dynamical properties of the magnetotail plasmas and the possible generation of non-Maxwellian features in the distribution functions are discussed.

  20. The host immunological response to cancer therapy: An emerging concept in tumor biology

    International Nuclear Information System (INIS)

    Voloshin, Tali; Voest, Emile E.; Shaked, Yuval

    2013-01-01

    Almost any type of anti-cancer treatment including chemotherapy, radiation, surgery and targeted drugs can induce host molecular and cellular immunological effects which, in turn, can lead to tumor outgrowth and relapse despite an initial successful therapy outcome. Tumor relapse due to host immunological effects is attributed to angiogenesis, tumor cell dissemination from the primary tumors and seeding at metastatic sites. This short review will describe the types of host cells that participate in this process, the types of factors secreted from the host following therapy that can promote tumor re-growth, and the possible implications of this unique and yet only partially-known process. It is postulated that blocking these specific immunological effects in the reactive host in response to cancer therapy may aid in identifying new host-dependent targets for cancer, which in combination with conventional treatments can prolong therapy efficacy and extend survival. Additional studies investigating this specific research direction—both in preclinical models and in the clinical setting are essential in order to advance our understanding of how tumors relapse and evade therapy. -- Highlights: • Cancer therapy induces host molecular and cellular pro-tumorigenic effects. • Host effects in response to therapy may promote tumor relapse and metastasis. • The reactive host consists of immunological mediators promoting tumor re-growth. • Blocking therapy-induced host mediators may improve outcome

  1. The host immunological response to cancer therapy: An emerging concept in tumor biology

    Energy Technology Data Exchange (ETDEWEB)

    Voloshin, Tali [Department of Molecular Pharmacology, Rappaport Faculty of Medicine and the Rappaport Institute, Technion—Israel Institute of Technology, 1 Efron Street, Bat Galim, Haifa 31096 (Israel); Voest, Emile E. [Department of Medical Oncology, University Medical Center Utrecht, Utrecht (Netherlands); Shaked, Yuval, E-mail: yshaked@tx.technion.ac.il [Department of Molecular Pharmacology, Rappaport Faculty of Medicine and the Rappaport Institute, Technion—Israel Institute of Technology, 1 Efron Street, Bat Galim, Haifa 31096 (Israel)

    2013-07-01

    Almost any type of anti-cancer treatment including chemotherapy, radiation, surgery and targeted drugs can induce host molecular and cellular immunological effects which, in turn, can lead to tumor outgrowth and relapse despite an initial successful therapy outcome. Tumor relapse due to host immunological effects is attributed to angiogenesis, tumor cell dissemination from the primary tumors and seeding at metastatic sites. This short review will describe the types of host cells that participate in this process, the types of factors secreted from the host following therapy that can promote tumor re-growth, and the possible implications of this unique and yet only partially-known process. It is postulated that blocking these specific immunological effects in the reactive host in response to cancer therapy may aid in identifying new host-dependent targets for cancer, which in combination with conventional treatments can prolong therapy efficacy and extend survival. Additional studies investigating this specific research direction—both in preclinical models and in the clinical setting are essential in order to advance our understanding of how tumors relapse and evade therapy. -- Highlights: • Cancer therapy induces host molecular and cellular pro-tumorigenic effects. • Host effects in response to therapy may promote tumor relapse and metastasis. • The reactive host consists of immunological mediators promoting tumor re-growth. • Blocking therapy-induced host mediators may improve outcome.

  2. On-orbit technology experiment facility definition

    Science.gov (United States)

    Russell, Richard A.; Buchan, Robert W.; Gates, Richard M.

    1988-01-01

    A study was conducted to identify on-orbit integrated facility needs to support in-space technology experiments on the Space Station and associated free flyers. In particular, the first task was to examine the proposed technology development missions (TDMX's) from the model mission set and other proposed experimental facilities, both individually and by theme, to determine how and if the experiments might be combined, what equipment might be shared, what equipment might be used as generic equipment for continued experimentation, and what experiments will conflict with the conduct of other experiments or Space Station operations. Then using these results, to determine on-orbit facility needs to optimize the implementation of technology payloads. Finally, to develop one or more scenarios, design concepts, and outfitting requirements for implementation of onboard technology experiments.

  3. [Exenteration of the Orbit for Basal Cell Carcinoma].

    Science.gov (United States)

    Furdová, A; Horkovičová, K; Krčová, I; Krásnik, V

    2015-08-01

    Primary treatment of basal cell carcinoma of the lower eyelid and the inner corner is essentially surgical, but advanced lesions require extensive surgical interventions. In some cases it is necessary to continue with the mutilating surgery--exenteration of the orbit. In this work we evaluate the indications of radical solutions in patients with basal cell carcinoma invading the orbit and the subsequent possibility for individually made prosthesis to cover the defect of the cavity. Indications to exenteration of the orbit in patients with basal cell carcinoma findings in 2008-2013. Case report of 2 patients. In period 2008-20013 at the Dept. of Ophthalmology, Comenius University in Bratislava totally 221 patients with histologically confirmed basal cell carcinoma of the eyelids and the inner corner were treated. In 5 cases (2.7 %) with infiltration of the orbit the radical surgical procedure, exenteration was necessary. In 3 patients exenteration was indicated as the first surgical procedure in the treatment of basal cell carcinoma, since they had never visited ophthalmologist before only at in the stage of infiltration of the orbit (stage T4). In one case was indicated exenteration after previous surgical interventions and relapses. After healing the cavity patients got individually prepared epithesis. Surgical treatment of basal cell carcinoma involves the radical removal of the neoplasm entire eyelid and stage T1 or T2 can effectively cure virtually all tumors with satisfactory cosmetic and functional results. In advanced stages (T4 stage) by infiltrating the orbit by basal cell carcinoma exenteration of the orbit is necessary. This surgery is a serious situation for the patient and also for his relatives. Individually made prosthesis helps the patient to be enrolled to the social environment.

  4. Gene discovery in glioma in the context of molecular reclassification of tumors

    Directory of Open Access Journals (Sweden)

    Khushboo Irshad

    2015-12-01

    Full Text Available Conventional classification of tumors, especially in terms of staging and grading is of immense importance for both prognostication as well as management strategies. However it is not a perfect system and there are many instances where tumor behaviour does not correspond to what is expected. In addition, with the onset of targeted therapy, the identification of the distinct molecular target in a subset of tumors becomes a marker of tumor behaviour as well as a target of therapy. This leads to the concept of molecular subclassification of tumors where molecular markers further refine and in some cases, alter conventional classification. We would be presenting this concept in relation to glial tumors, especially in the context of molecular markers discovered in our laboratory.

  5. Single-stage-to-orbit: Meeting the challenge

    Science.gov (United States)

    Freeman, Delma C., Jr.; Talay, Theodore A.; Austin, Robert Eugene

    1995-10-01

    There has been and continues to be significant discussion about the viability of fully reusable, single-stage-to-orbit (SSTO) concepts for delivery of payloads to orbit. Often, these discussions have focused in detail on performance and technology requirements relating to the technical feasibility of the concept, with only broad generalizations on how the SSTO will achieve its economic goals of greatly reduced vehicle ground and flight operations costs. With the current industry and NASA Reusable Launch Vehicle Technology Program efforts underway to mature and demonstrate technologies leading to a viable commercial launch system that also satisfies national needs, achieving acceptable recurring costs becomes a significant challenge. This paper reviews the current status of the Reusable Launch Vehicle Technology Program including the DC-XA, X-33, and X-34 flight systems and associated technology programs. The paper also examines lessons learned from the recently completed DC-X reusable rocket demonstrator program. It examines how these technologies and flight systems address the technical and operability challenges of SSTO whose solutions are necessary to reduce costs. The paper also discusses the management and operational approaches that address the challenge of a new cost-effective, reusable launch vehicle system.

  6. Hierarchy of on-orbit servicing interfaces

    Science.gov (United States)

    Moe, Rud V.

    1989-01-01

    A series of equipment interfaces is involved in on-orbit servicing operations. The end-to-end hierarchy of servicing interfaces is presented. The interface concepts presented include structure and handling, and formats for transfer of resources (power, data, fluids, etc.). Consequences on cost, performance, and service ability of the use of standard designs or unique designs with interface adapters are discussed. Implications of the interface designs compatibility with remote servicing using telerobotic servicers are discussed.

  7. DC-DC power converter research for Orbiter/Station power exchange

    Science.gov (United States)

    Ehsani, M.

    1993-01-01

    This project was to produce innovative DC-DC power converter concepts which are appropriate for the power exchange between the Orbiter and the Space Station Freedom (SSF). The new converters must interface three regulated power buses on SSF, which are at different voltages, with three fuel cell power buses on the Orbiter which can be at different voltages and should be tracked independently. Power exchange is to be bi-directional between the SSF and the Orbiter. The new converters must satisfy the above operational requirements with better weight, volume, efficiency, and reliability than is available from the present conventional technology. Two families of zero current DC-DC converters were developed and successfully adapted to this application. Most of the converters developed are new and are presented.

  8. New perspectives for Rashba spin–orbit coupling

    KAUST Repository

    Manchon, Aurelien; Koo, H. C.; Nitta, J.; Frolov, S. M.; Duine, R. A.

    2015-01-01

    In 1984, Bychkov and Rashba introduced a simple form of spin-orbit coupling to explain the peculiarities of electron spin resonance in two-dimensional semiconductors. Over the past 30 years, Rashba spin-orbit coupling has inspired a vast number of predictions, discoveries and innovative concepts far beyond semiconductors. The past decade has been particularly creative, with the realizations of manipulating spin orientation by moving electrons in space, controlling electron trajectories using spin as a steering wheel, and the discovery of new topological classes of materials. This progress has reinvigorated the interest of physicists and materials scientists in the development of inversion asymmetric structures, ranging from layered graphene-like materials to cold atoms. This Review discusses relevant recent and ongoing realizations of Rashba physics in condensed matter.

  9. New perspectives for Rashba spin–orbit coupling

    KAUST Repository

    Manchon, Aurelien

    2015-08-20

    In 1984, Bychkov and Rashba introduced a simple form of spin-orbit coupling to explain the peculiarities of electron spin resonance in two-dimensional semiconductors. Over the past 30 years, Rashba spin-orbit coupling has inspired a vast number of predictions, discoveries and innovative concepts far beyond semiconductors. The past decade has been particularly creative, with the realizations of manipulating spin orientation by moving electrons in space, controlling electron trajectories using spin as a steering wheel, and the discovery of new topological classes of materials. This progress has reinvigorated the interest of physicists and materials scientists in the development of inversion asymmetric structures, ranging from layered graphene-like materials to cold atoms. This Review discusses relevant recent and ongoing realizations of Rashba physics in condensed matter.

  10. Tumor taxonomy for the developmental lineage classification of neoplasms

    International Nuclear Information System (INIS)

    Berman, Jules J

    2004-01-01

    The new 'Developmental lineage classification of neoplasms' was described in a prior publication. The classification is simple (the entire hierarchy is described with just 39 classifiers), comprehensive (providing a place for every tumor of man), and consistent with recent attempts to characterize tumors by cytogenetic and molecular features. A taxonomy is a list of the instances that populate a classification. The taxonomy of neoplasia attempts to list every known term for every known tumor of man. The taxonomy provides each concept with a unique code and groups synonymous terms under the same concept. A Perl script validated successive drafts of the taxonomy ensuring that: 1) each term occurs only once in the taxonomy; 2) each term occurs in only one tumor class; 3) each concept code occurs in one and only one hierarchical position in the classification; and 4) the file containing the classification and taxonomy is a well-formed XML (eXtensible Markup Language) document. The taxonomy currently contains 122,632 different terms encompassing 5,376 neoplasm concepts. Each concept has, on average, 23 synonyms. The taxonomy populates 'The developmental lineage classification of neoplasms,' and is available as an XML file, currently 9+ Megabytes in length. A representation of the classification/taxonomy listing each term followed by its code, followed by its full ancestry, is available as a flat-file, 19+ Megabytes in length. The taxonomy is the largest nomenclature of neoplasms, with more than twice the number of neoplasm names found in other medical nomenclatures, including the 2004 version of the Unified Medical Language System, the Systematized Nomenclature of Medicine Clinical Terminology, the National Cancer Institute's Thesaurus, and the International Classification of Diseases Oncolology version. This manuscript describes a comprehensive taxonomy of neoplasia that collects synonymous terms under a unique code number and assigns each

  11. Orbital irradiation for Graves' ophthalmopathy - Is it safe? A long-term follow-up study

    NARCIS (Netherlands)

    Wakelkamp, Iris M. M. J.; Tan, Hendra; Saeed, Peerooz; Schlingemann, Reinier O.; Verbraak, Frank D.; Blank, Leo E. C. M.; Prummel, Mark F.; Wiersinga, Wilmar M.

    2004-01-01

    Purpose: We evaluated the frequency of long-term complications of orbital irradiation (radiation-induced tumors, cataract, and retinopathy) in comparison with glucocorticoids. Design: We conducted a follow-up study in a cohort of 245 Graves' ophthalmopathy patients who had been treated with

  12. The PCa Tumor Microenvironment.

    Science.gov (United States)

    Sottnik, Joseph L; Zhang, Jian; Macoska, Jill A; Keller, Evan T

    2011-12-01

    The tumor microenvironment (TME) is a very complex niche that consists of multiple cell types, supportive matrix and soluble factors. Cells in the TME consist of both host cells that are present at tumor site at the onset of tumor growth and cells that are recruited in either response to tumor- or host-derived factors. PCa (PCa) thrives on crosstalk between tumor cells and the TME. Crosstalk results in an orchestrated evolution of both the tumor and microenvironment as the tumor progresses. The TME reacts to PCa-produced soluble factors as well as direct interaction with PCa cells. In return, the TME produces soluble factors, structural support and direct contact interactions that influence the establishment and progression of PCa. In this review, we focus on the host side of the equation to provide a foundation for understanding how different aspects of the TME contribute to PCa progression. We discuss immune effector cells, specialized niches, such as the vascular and bone marrow, and several key protein factors that mediate host effects on PCa. This discussion highlights the concept that the TME offers a potentially very fertile target for PCa therapy.

  13. Treatment of giant cell tumor of bone: Current concepts.

    Science.gov (United States)

    Puri, Ajay; Agarwal, Manish

    2007-04-01

    Giant cell tumor (GCT) of bone though one of the commonest bone tumors encountered by an orthopedic surgeon continues to intrigue treating surgeons. Usually benign, they are locally aggressive and may occasionally undergo malignant transformation. The surgeon needs to strike a balance during treatment between reducing the incidence of local recurrence while preserving maximal function.Differing opinions pertaining to the use of adjuvants for extension of curettage, the relative role of bone graft or cement to pack the defect and the management of recurrent lesions are some of the issues that offer topics for eternal debate.Current literature suggests that intralesional curettage strikes the best balance between controlling disease and preserving optimum function in the majority of the cases though there may be occasions where the extent of the disease mandates resection to ensure adequate disease clearance.An accompanying treatment algorithm helps outline the management strategy in GCT.

  14. Treatment of giant cell tumor of bone: Current concepts

    Directory of Open Access Journals (Sweden)

    Puri Ajay

    2007-01-01

    Full Text Available Giant cell tumor (GCT of bone though one of the commonest bone tumors encountered by an orthopedic surgeon continues to intrigue treating surgeons. Usually benign, they are locally aggressive and may occasionally undergo malignant transformation. The surgeon needs to strike a balance during treatment between reducing the incidence of local recurrence while preserving maximal function. Differing opinions pertaining to the use of adjuvants for extension of curettage, the relative role of bone graft or cement to pack the defect and the management of recurrent lesions are some of the issues that offer topics for eternal debate. Current literature suggests that intralesional curettage strikes the best balance between controlling disease and preserving optimum function in the majority of the cases though there may be occasions where the extent of the disease mandates resection to ensure adequate disease clearance. An accompanying treatment algorithm helps outline the management strategy in GCT.

  15. Fat suppression applied to MR imaging of the pathologic orbit

    International Nuclear Information System (INIS)

    Simon, J.H.; Kido, D.K.; Ekholm, S.E.; Totterman, S.; Szumowski, J.; Manzione, J.V. Jr.; Joy, S.E.

    1987-01-01

    Previous MR studies of the normal orbit have shown that fat suppression sequences applied at the proper T1-T2 weighting will decrease artifacts from chemical shift, and can be used to enhance contrast in selected anatomic regions. The purpose of this study was to evaluate the clinical application of fat suppression to studies of the pathologic orbit. The studies included conventional imaging sequences and comparative fat suppression sequences through a range of T1-T2 weighting (repetition time [TR] 400 msec, echo time [TE]20 msec, to TR 2,000 msec, TE 90 msec), using the chopper fat suppression technique developed by J. Szumowski and D. Plewes, which requires no postprocessing and no increased scan time to achieve relatively linear fat suppression. Fat suppression was advantageous in determining tumor margins (extension through sclera); increasing diagnostic specificity (fat vs. water content); detailing anatomic relationships along bony margins (particularly in the orbital apex); and for demonstrating true thickness of optic nerve separate from adjacent cerebrospinal fluid and fibrous sheath. Disadvantages included susceptibility to motion artifact and a perception of lower quality due to lower overall orbital signal

  16. Selected anti-tumor vaccines merit a place in multimodal tumor therapies

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, Eva-Maria; Wunderlich, Roland [Department of Radiation Oncology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen (Germany); Ebel, Nina [Department of Process Technology and Machinery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen (Germany); Rubner, Yvonne [Department of Radiation Oncology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen (Germany); Schlücker, Eberhard [Department of Process Technology and Machinery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen (Germany); Meyer-Pittroff, Roland [Competence Pool Weihenstephan, Technische Universität München, Freising (Germany); Ott, Oliver J.; Fietkau, Rainer; Gaipl, Udo S.; Frey, Benjamin, E-mail: benjamin.frey@uk-erlangen.de [Department of Radiation Oncology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen (Germany)

    2012-10-09

    Multimodal approaches are nowadays successfully applied in cancer therapy. Primary locally acting therapies such as radiotherapy (RT) and surgery are combined with systemic administration of chemotherapeutics. Nevertheless, the therapy of cancer is still a big challenge in medicine. The treatments often fail to induce long-lasting anti-tumor responses. Tumor recurrences and metastases result. Immunotherapies are therefore ideal adjuncts to standard tumor therapies since they aim to activate the patient's immune system against malignant cells even outside the primary treatment areas (abscopal effects). Especially cancer vaccines may have the potential both to train the immune system against cancer cells and to generate an immunological memory, resulting in long-lasting anti-tumor effects. However, despite promising results in phase I and II studies, most of the concepts finally failed. There are some critical aspects in development and application of cancer vaccines that may decide on their efficiency. The time point and frequency of medication, usage of an adequate immune adjuvant, the vaccine's immunogenic potential, and the tumor burden of the patient are crucial. Whole tumor cell vaccines have advantages compared to peptide-based ones since a variety of tumor antigens (TAs) are present. The master requirements of cell-based, therapeutic tumor vaccines are the complete inactivation of the tumor cells and the increase of their immunogenicity. Since the latter is highly connected with the cell death modality, the inactivation procedure of the tumor cell material may significantly influence the vaccine's efficiency. We therefore also introduce high hydrostatic pressure (HHP) as an innovative inactivation technology for tumor cell-based vaccines and outline that HHP efficiently inactivates tumor cells by enhancing their immunogenicity. Finally studies are presented proving that anti-tumor immune responses can be triggered by combining RT with selected

  17. The host immunological response to cancer therapy: An emerging concept in tumor biology.

    Science.gov (United States)

    Voloshin, Tali; Voest, Emile E; Shaked, Yuval

    2013-07-01

    Almost any type of anti-cancer treatment including chemotherapy, radiation, surgery and targeted drugs can induce host molecular and cellular immunological effects which, in turn, can lead to tumor outgrowth and relapse despite an initial successful therapy outcome. Tumor relapse due to host immunological effects is attributed to angiogenesis, tumor cell dissemination from the primary tumors and seeding at metastatic sites. This short review will describe the types of host cells that participate in this process, the types of factors secreted from the host following therapy that can promote tumor re-growth, and the possible implications of this unique and yet only partially-known process. It is postulated that blocking these specific immunological effects in the reactive host in response to cancer therapy may aid in identifying new host-dependent targets for cancer, which in combination with conventional treatments can prolong therapy efficacy and extend survival. Additional studies investigating this specific research direction-both in preclinical models and in the clinical setting are essential in order to advance our understanding of how tumors relapse and evade therapy. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Unilateral Eyelid Edema as Initial Sign of Orbital Sarcoidosis

    Directory of Open Access Journals (Sweden)

    Sílvia Miguéis Picado Petrarolha

    2016-01-01

    Full Text Available Introduction. Sarcoidosis is a rare multisystemic granulomatous inflammatory disease of unknown etiology affecting the respiratory system, skin, and eyes. Sarcoidosis outside the lacrimal gland is rare. The case study concerns a patient with a final diagnosis of orbital sarcoidosis. Case Report. A 37-year-old male patient went to the ophthalmic emergency room complaining of pain in the left eye, diplopia, and decreased visual acuity. An external eye examination showed hard and cold edema of the lower eyelid, ocular motility with limitation of adduction, and discreet ipsilateral proptosis. Magnetic resonance of the orbit showed left eye proptosis and thickening and increase of soft tissues associated with heterogeneous impregnation of contrast in the infralateral region of the left eyelid. A biopsy of the lesion showed a chronic inflammatory process, with numerous compact nonnecrotizing granulomas surrounded by lamellar hyaline collagen, providing histological confirmation of sarcoidosis. Discussion. A biopsy of the orbital tumor is essential for the diagnosis of sarcoidosis, in addition to the search for systemic findings such as hilar adenopathy or parenchymal lung disease found in 90% of patients.

  19. [Pott's puffy tumor: a rare complication of frontal sinusitis].

    Science.gov (United States)

    Aínsa Laguna, D; Pons Morales, S; Muñoz Tormo-Figueres, A; Vega Senra, M I; Otero Reigada, M C

    2014-05-01

    Pott's puffy tumor is a rare complication of frontal sinusitis characterized by swelling and edema in the brow due to a subperiosteal abscess associated with frontal osteomyelitis. Added complications are cellulitis by extension to the orbit and intracranial infection by posterior extension, with high risk of meningitis, intracranial abscess, and venous sinus thrombosis. Early diagnosis and aggressive medical or surgical treatment are essential for optimal recovery of affected patients. In the antibiotic age it is extremely rare, with very few cases described in the recent literature. A case is presented of a Pott inflammatory tumor in a 7 year-old boy, as a complication of acute pansinusitis who presented with front preseptal swelling and intracranial involvement with thrombosis of ophthalmic and superior orbital veins and frontal epidural abscess extending to the subarachnoid space. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  20. Management of CNS tumors

    International Nuclear Information System (INIS)

    Griem, M.L.

    1987-01-01

    The treatment of tumors of the CNS has undergone a number of changes based on the impact of CT. The use of intraoperative US for the establishment of tumor location and tumor histology is demonstrated. MR imaging also is beginning to make an impact on the diagnosis and treatment of tumors of the CNS. Examples of MR images are shown. The authors then discuss the important aspects of tumor histology as it affects management and newer concepts in surgery, radiation, and chemotherapy on tumor treatment. The role of intraoperative placement of radioactive sources, the utilization of heavy particle radiation therapy, and the potential role of other experimental radiation therapy techniques are discussed. The role of hyperfractionated radiation and of neutrons and x-ray in a mixed-beam treatment are discussed in perspective with standard radiation therapy. Current chemotherapy techniques, including intraarterial chemotherapy, are discussed. The complications of radiation therapy alone and in combination with chemotherapy in the management of primary brain tumors, brain metastases, and leukemia are reviewed. A summary of the current management of pituitary tumors, including secreting pituitary adenomas and chromophobe adenomas, are discussed. The treatment with heavy particle radiation, transsphenoidal microsurgical removal, and combined radiotherapeutic and surgical management are considered. Tumor metastasis management of lesions of the brain and spinal cord are considered

  1. Transition matrices and orbitals from reduced density matrix theory

    Energy Technology Data Exchange (ETDEWEB)

    Etienne, Thibaud [Université de Lorraine – Nancy, Théorie-Modélisation-Simulation, SRSMC, Boulevard des Aiguillettes 54506, Vandoeuvre-lès-Nancy (France); CNRS, Théorie-Modélisation-Simulation, SRSMC, Boulevard des Aiguillettes 54506, Vandoeuvre-lès-Nancy (France); Unité de Chimie Physique Théorique et Structurale, Université de Namur, Rue de Bruxelles 61, 5000 Namur (Belgium)

    2015-06-28

    In this contribution, we report two different methodologies for characterizing the electronic structure reorganization occurring when a chromophore undergoes an electronic transition. For the first method, we start by setting the theoretical background necessary to the reinterpretation through simple tensor analysis of (i) the transition density matrix and (ii) the natural transition orbitals in the scope of reduced density matrix theory. This novel interpretation is made more clear thanks to a short compendium of the one-particle reduced density matrix theory in a Fock space. The formalism is further applied to two different classes of excited states calculation methods, both requiring a single-determinant reference, that express an excited state as a hole-particle mono-excited configurations expansion, to which particle-hole correlation is coupled (time-dependent Hartree-Fock/time-dependent density functional theory) or not (configuration interaction single/Tamm-Dancoff approximation). For the second methodology presented in this paper, we introduce a novel and complementary concept related to electronic transitions with the canonical transition density matrix and the canonical transition orbitals. Their expression actually reflects the electronic cloud polarisation in the orbital space with a decomposition based on the actual contribution of one-particle excitations from occupied canonical orbitals to virtual ones. This approach validates our novel interpretation of the transition density matrix elements in terms of the Euclidean norm of elementary transition vectors in a linear tensor space. A proper use of these new concepts leads to the conclusion that despite the different principles underlying their construction, they provide two equivalent excited states topological analyses. This connexion is evidenced through simple illustrations of (in)organic dyes electronic transitions analysis.

  2. A Preliminary Formation Flying Orbit Dynamics Analysis for Leonardo-BRDF

    Science.gov (United States)

    Hughes, Steven P.; Mailhe, Laurie M.

    2001-01-01

    Leonardo-BRDF is a NASA mission concept proposed to allow the investigation of radiative transfer and its effect on the Earth's climate and atmospheric phenomenon. Enabled by the recent developments in small-satellite and formation flying technology, the mission is envisioned to be composed of an array of spacecraft in carefully designed orbits. The different perspectives provided by a distributed array of spacecraft offer a unique advantage to study the Earth's albedo. This paper presents the orbit dynamics analysis performed in the context of the Leonardo-BRDF science requirements. First, the albedo integral is investigated and the effect of viewing geometry on science return is studied. The method used in this paper, based on Gauss quadrature, provides the optimal formation geometry to ensure that the value of the integral is accurately approximated. An orbit design approach is presented to achieve specific relative orbit geometries while simultaneously satisfying orbit dynamics constraints to reduce formation-keeping fuel expenditure. The relative geometry afforded by the design is discussed in terms of mission requirements. An optimal two-burn initialization scheme is presented with the required delta-V to distribute all spacecraft from a common parking orbit into their appropriate orbits in the formation. Finally, formation-keeping strategies are developed and the associated delta-V's are calculated to maintain the formation in the presence of perturbations.

  3. Neuroradiolological diagnosis and follow-up of brain tumors

    International Nuclear Information System (INIS)

    Kummer, R. von

    1997-01-01

    Primary tumors of the brain and cerebral metastases cause considerable morbidity and mortality. To assess the chance for cure and to develop a valid concept of treatment, the exact assessment of the tumor's location, of the tumor's borders and malignancy is essential. Today, neuroradiological examination mainly with magnetic resonance imaging (MRI) allows an almost histological diagnosis and description of the tumor's extent. MRI is as well useful for studying the patient's short- and long-term follow-up clinical course. This is illustrated by 3 case histories. (orig.)

  4. Multiple orbital angular momentum generated by dielectric hybrid phase element

    Science.gov (United States)

    Wang, Xuewen; Kuchmizhak, Aleksandr; Hu, Dejiao; Li, Xiangping

    2017-09-01

    Vortex beam carrying multiple orbital angular momentum provides a new degree of freedom to manipulate light leading to the various exciting applications as trapping, quantum optics, information multiplexing, etc. Helical wavefront can be generated either via the geometric or the dynamic phase arising from a space-variant birefringence (q-plate) or from phase accumulation through propagation (spiral-phase-plate), respectively. Using fast direct laser writing technique we fabricate and characterize novel hybrid q-plate generating vortex beam simultaneously carrying two different high-order topological charges, which arise from the spin-orbital conversion and the azimuthal height variation of the recorded structures. We approve the versatile concept to generate multiple-OAM vortex beams combining the spin-orbital interaction and the phase accumulation in a single micro-scale device, a hybrid dielectric phase plate.

  5. Interactive orbital proximity operations planning system

    Science.gov (United States)

    Grunwald, Arthur J.; Ellis, Stephen R.

    1990-01-01

    An interactive graphical planning system for on-site planning of proximity operations in the congested multispacecraft environment about the space station is presented. The system shows the astronaut a bird's eye perspective of the space station, the orbital plane, and the co-orbiting spacecraft. The system operates in two operational modes: (1) a viewpoint mode, in which the astronaut is able to move the viewpoint around in the orbital plane to range in on areas of interest; and (2) a trajectory design mode, in which the trajectory is planned. Trajectory design involves the composition of a set of waypoints which result in a fuel-optimal trajectory which satisfies all operational constraints, such as departure and arrival constraints, plume impingement constraints, and structural constraints. The main purpose of the system is to present the trajectory and the constraints in an easily interpretable graphical format. Through a graphical interactive process, the trajectory waypoints are edited until all operational constraints are satisfied. A series of experiments was conducted to evaluate the system. Eight airline pilots with no prior background in orbital mechanics participated in the experiments. Subject training included a stand-alone training session of about 6 hours duration, in which the subjects became familiar with orbital mechanics concepts and performed a series of exercises to familiarize themselves with the control and display features of the system. They then carried out a series of production runs in which 90 different trajectory design situations were randomly addressed. The purpose of these experiments was to investigate how the planning time, planning efforts, and fuel expenditures were affected by the planning difficulty. Some results of these experiments are presented.

  6. Orbital mechanics and astrodynamics techniques and tools for space missions

    CERN Document Server

    Hintz, Gerald R

    2015-01-01

    This textbook covers fundamental and advanced topics in orbital mechanics and astrodynamics to expose the student to the basic dynamics of space flight. The engineers and graduate students who read this class-tested text will be able to apply their knowledge to mission design and navigation of space missions. Through highlighting basic, analytic and computer-based methods for designing interplanetary and orbital trajectories, this text provides excellent insight into astronautical techniques and tools. This book is ideal for graduate students in Astronautical or Aerospace Engineering and related fields of study, researchers in space industrial and governmental research and development facilities, as well as researchers in astronautics. This book also: ·       Illustrates all key concepts with examples ·       Includes exercises for each chapter ·       Explains concepts and engineering tools a student or experienced engineer can apply to mission design and navigation of space missions ·�...

  7. CASTOR: Cathode/Anode Satellite Thruster for Orbital Repositioning

    Science.gov (United States)

    Mruphy, Gloria A.

    2010-01-01

    The purpose of CASTOR (Cathode/Anode Satellite Thruster for Orbital Repositioning) satellite is to demonstrate in Low Earth Orbit (LEO) a nanosatellite that uses a Divergent Cusped Field Thruster (DCFT) to perform orbital maneuvers representative of an orbital transfer vehicle. Powered by semi-deployable solar arrays generating 165W of power, CASTOR will achieve nearly 1 km/s of velocity increment over one year. As a technology demonstration mission, success of CASTOR in LEO will pave the way for a low cost, high delta-V orbital transfer capability for small military and civilian payloads in support of Air Force and NASA missions. The educational objective is to engage graduate and undergraduate students in critical roles in the design, development, test, carrier integration and on-orbit operations of CASTOR as a supplement to their curricular activities. This program is laying the foundation for a long-term satellite construction program at MIT. The satellite is being designed as a part of AFRL's University Nanosatellite Program, which provides the funding and a framework in which student satellite teams compete for a launch to orbit. To this end, the satellite must fit within an envelope of 50cmx50cmx60cm, have a mass of less than 50kg, and meet stringent structural and other requirements. In this framework, the CASTOR team successfully completed PDR in August 2009 and CDR in April 2010 and will compete at FCR (Flight Competition Review) in January 2011. The complexity of the project requires implementation of many systems engineering techniques which allow for development of CASTOR from conception through FCR and encompass the full design, fabrication, and testing process.

  8. SensorWeb 3G: Extending On-Orbit Sensor Capabilities to Enable Near Realtime User Configurability

    Science.gov (United States)

    Mandl, Daniel; Cappelaere, Pat; Frye, Stuart; Sohlberg, Rob; Ly, Vuong; Chien, Steve; Tran, Daniel; Davies, Ashley; Sullivan, Don; Ames, Troy; hide

    2010-01-01

    This research effort prototypes an implementation of a standard interface, Web Coverage Processing Service (WCPS), which is an Open Geospatial Consortium(OGC) standard, to enable users to define, test, upload and execute algorithms for on-orbit sensor systems. The user is able to customize on-orbit data products that result from raw data streaming from an instrument. This extends the SensorWeb 2.0 concept that was developed under a previous Advanced Information System Technology (AIST) effort in which web services wrap sensors and a standardized Extensible Markup Language (XML) based scripting workflow language orchestrates processing steps across multiple domains. SensorWeb 3G extends the concept by providing the user controls into the flight software modules associated with on-orbit sensor and thus provides a degree of flexibility which does not presently exist. The successful demonstrations to date will be presented, which includes a realistic HyspIRI decadal mission testbed. Furthermore, benchmarks that were run will also be presented along with future demonstration and benchmark tests planned. Finally, we conclude with implications for the future and how this concept dovetails into efforts to develop "cloud computing" methods and standards.

  9. Radiotherapy in the management of orbital lymphoma

    International Nuclear Information System (INIS)

    Bolek, Timothy W.; Moyses, H. Michael; Marcus, Robert B.; Gorden, Lemuel; Maiese, Russell L.; Almasri, Nidal M.; Mendenhall, Nancy Price

    1999-01-01

    Purpose: This retrospective study reviews the treatment technique, disease outcome, and complications of radiotherapy used in the management of lymphoma involving the orbits. Patients and Methods: Thirty-eight patients were treated between May 1969 and January 1995, with a median follow-up of 8.3 years. All patients had biopsy-proven orbital lymphoma. Twenty patients who had limited disease were treated with curative intent, and 18 patients who had known systemic disease were treated with palliative intent. Of the 20 patients treated with curative intent, 14 had low-grade and 6 had intermediate- or high-grade disease. None received chemotherapy. Most patients received treatment with 250 kVP or 60 Co radiation, using either an en face anterior field or wedged anterior and lateral fields. Median treatment dose was 25 Gy. Lens shielding was performed if possible. For patients treated for cure, cause-specific survival and freedom from distant relapse were calculated using the Kaplan-Meier method. Results: Control of disease in the orbit was achieved in all but 1 patient, who developed an out-of-field recurrence after irradiation of a lacrimal tumor and was salvaged with further radiotherapy. In the patients treated curatively, the 5-year rate of actuarial freedom from distant relapse was 61% for those with low-grade and 33% for those with intermediate/high-grade disease (p = 0.08). Cause-specific survival at 5 years was 89% for patients with low-grade and 33% for those with intermediate/high-grade disease (p = 0.005). Two patients with low-grade disease had contralateral orbital failures; both were salvaged with further irradiation. Acute toxicity was minimal. Cataracts developed in 7 of 21 patients treated without lens shielding and 0 of 17 patients treated with lens shielding. No patient developed significant late lacrimal toxicity. Conclusion: Radiotherapy is a safe and effective local treatment in the management of orbital lymphoma

  10. Destructive quantum interference in electron transport: A reconciliation of the molecular orbital and the atomic orbital perspective

    Science.gov (United States)

    Zhao, Xin; Geskin, Victor; Stadler, Robert

    2017-03-01

    Destructive quantum interference (DQI) in single molecule electronics is a purely quantum mechanical effect and is entirely defined by the inherent properties of the molecule in the junction such as its structure and symmetry. This definition of DQI by molecular properties alone suggests its relation to other more general concepts in chemistry as well as the possibility of deriving simple models for its understanding and molecular device design. Recently, two such models have gained a wide spread attention, where one was a graphical scheme based on visually inspecting the connectivity of the carbon sites in conjugated π systems in an atomic orbital (AO) basis and the other one puts the emphasis on the amplitudes and signs of the frontier molecular orbitals (MOs). There have been discussions on the range of applicability for these schemes, but ultimately conclusions from topological molecular Hamiltonians should not depend on whether they are drawn from an AO or a MO representation, as long as all the orbitals are taken into account. In this article, we clarify the relation between both models in terms of the zeroth order Green's function and compare their predictions for a variety of systems. From this comparison, we conclude that for a correct description of DQI from a MO perspective, it is necessary to include the contributions from all MOs rather than just those from the frontier orbitals. The cases where DQI effects can be successfully predicted within a frontier orbital approximation we show them to be limited to alternant even-membered hydrocarbons, as a direct consequence of the Coulson-Rushbrooke pairing theorem in quantum chemistry.

  11. Mean Orbital Elements for Geosynchronous Orbit - II - Orbital inclination, longitude of ascending node, mean longitude

    Directory of Open Access Journals (Sweden)

    Kyu-Hong Choi

    1990-06-01

    Full Text Available The osculating orbital elements include the mean, secular, long period, and short period terms. The iterative algorithm used for conversion of osculating orbital elements to mean orbital elements is described. The mean orbital elements of Wc, Ws, and L are obtained.

  12. Malignant tumors of the nasal cavity: computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Souza, Ricardo Pires de; Paes Junior, Ademar Jose de Oliveira; Gonzalez, Fabio Mota; Cordeiro, Flamarion de Barros; Yamashiro, Ilka; Lenh, Carlos Neutzling; Rapoport, Abrao

    2004-01-01

    The aim of this study is to evaluate the role of computed tomography and magnetic resonance imaging in the characterization of deep tissue extension of malignant tumors of the nasal cavity. Twelve patients diagnosed with malignant tumors of the nasal cavity were retrospectively evaluated at the Departments of Diagnostic Imaging and Head and Neck Surgery of the 'Complexo Hospitalar Heliopolis', Sao Paulo, Brazil, between 1990 and 2000. All cases were confirmed by histopathologic examination. The results were: extension to the maxillary and ethmoid sinuses was identified in six patients, extension to contralateral nasal cavity, orbit and lamina cribosa in five patients, extension to nasal pharynx and masticator space in two patients, extension to cavernous sinus, anterior/middle cranial fossa, pterygomaxillary fossa, inferior/superior orbital fissure, frontal sinus, contralateral ethmoid sinus, contralateral lamina cribosa, hard palate and pterygopalatine fossa in one patient. Conclusion: It is important to precisely assess the local extension and spread of tumor by computed tomography and magnetic resonance imaging in order to plan the approach to treatment, which will influence the prognosis. (author)

  13. A review of nasal, paranasal, and skull base tumors invading the orbit

    DEFF Research Database (Denmark)

    Jørgensen, Morten; Heegaard, Steffen

    2018-01-01

    of ophthalmological and otorhinolaryngological symptoms, including proptosis, pain, decreased visual acuity, restrictions in motility of the eye, epistaxis, and nasal obstruction. Sarcomas and benign bone and cartilage tumors arise from surrounding structures, whereas carcinomas usually arise from the paranasal...

  14. Single-stage-to-orbit — Meeting the challenge

    Science.gov (United States)

    Freeman, Delma C.; Talay, Theodore A.; Austin, Robert Eugene

    1996-02-01

    There has been and continues to be significant discussion about the viability of fully reusable, single-stage-to-orbit (SSTO) concepts for delivery of payloads to orbit. Often, these discussions have focused in detail on performance and technology requirements relating to the technical feasibility of the concept, with only broad generalizations on how the SSTO will achieve its economic goals of greatly reduced vehicle ground and flight operations costs. With the current industry and NASA Reusable Launch Vehicle Technology Program efforts underway to mature and demonstrate technologies leading to a viable commercial launch system that also satisfies national needs, achieving acceptable recurring costs becomes a significant challenge. This paper reviews the current status of the Reusable Launch Vehicle Technology Program including the DC-XA, X-33, X-34 flight systems and associated technology programs. The paper also examines lessons learned from the recently completed DC-X reusable rocket demonstrator program. It examines how these technologies and flight systems address the technical and operability challenges of SSTO whose solutions are necessary to reduce costs. The paper also discusses the management and operational approaches that address the challenge of a new cost-effective, reusable launch vehicle system.

  15. Magnetic resonance tomography of the orbit: First experiences with the paramagnetic contrast medium gadolinium-DTPA

    International Nuclear Information System (INIS)

    Markl, A.; Vogl, T.; Scheidhauer, K.; Riedel, K.G.; Oeckler, R.

    1986-01-01

    In 21 patients with orbital mass lesions MRI was performed before and after administration of paramagnetic contrast medium, gadolinium-DPTA. In comparison to the plain scan the differentiation of the tumorous tissue against the surrounding structures was improved after application of contrast medium despite a partially moderate increase in signal intensity. Especially highly vascular tumors and vessel diseases show a significant contrast enhancement. With increasing experience in larger number of patients a tissue differentiation seems to be possible. (orig.) [de

  16. Architectural Design for a Mars Communications and Navigation Orbital Infrastructure

    Science.gov (United States)

    Ceasrone R. J.; Hastrup, R. C.; Bell, D. J.; Roncoli, R. B.; Nelson, K.

    1999-01-01

    The planet Mars has become the focus of an intensive series of missions that span decades of time, a wide array of international agencies and an evolution from robotics to humans. The number of missions to Mars at any one time, and over a period of time, is unprecedented in the annals of space exploration. To meet the operational needs of this exploratory fleet will require the implementation of new architectural concepts for communications and navigation. To this end, NASA's Jet Propulsion Laboratory has begun to define and develop a Mars communications and navigation orbital infrastructure. This architecture will make extensive use of assets at Mars, as well as use of traditional Earth-based assets, such as the Deep Space Network, DSN. Indeed, the total system can be thought of as an extension of DSN nodes and services to the Mars in-situ region. The concept has been likened to the beginnings of an interplanetary Internet that will bring the exploration of Mars right into our living rooms. The paper will begin with a high-level overview of the concept for the Mars communications and navigation infrastructure. Next, the mission requirements will be presented. These will include the relatively near-term needs of robotic landers, rovers, ascent vehicles, balloons, airplanes, and possibly orbiting, arriving and departing spacecraft. Requirements envisioned for the human exploration of Mars will also be described. The important Mars orbit design trades on telecommunications and navigation capabilities will be summarized, and the baseline infrastructure will be described. A roadmap of NASA's plan to evolve this infrastructure over time will be shown. Finally, launch considerations and delivery to Mars will be briefly treated.

  17. Identification and Reconstruction of Prostate Tumor-Suppressing Exosomes for Therapeutic Applications

    Science.gov (United States)

    2016-03-01

    to the altered contents of exosomes , those from prostate cancer cells (tumor exosomes ) no longer have tumor suppressive functions. If this... cancer . To develop this concept, exosomes will be isolated from normal prostate epithelial cells by differential centrifugations or affinity...purifications and evaluated for tumor suppressing activities against various prostate cancer cells (Aim 1). Then the components of the tumor suppressing exosomes

  18. PyORBIT: A Python Shell For ORBIT

    Energy Technology Data Exchange (ETDEWEB)

    Jean-Francois Ostiguy; Jeffrey Holmes

    2003-07-01

    ORBIT is code developed at SNS to simulate beam dynamics in accumulation rings and synchrotrons. The code is structured as a collection of external C++ modules for SuperCode, a high level interpreter shell developed at LLNL in the early 1990s. SuperCode is no longer actively supported and there has for some time been interest in replacing it by a modern scripting language, while preserving the feel of the original ORBIT program. In this paper, we describe a new version of ORBIT where the role of SuperCode is assumed by Python, a free, well-documented and widely supported object-oriented scripting language. We also compare PyORBIT to ORBIT from the standpoint of features, performance and future expandability.

  19. PyORBIT: A Python Shell For ORBIT

    International Nuclear Information System (INIS)

    Jean-Francois Ostiguy; Jeffrey Holmes

    2003-01-01

    ORBIT is code developed at SNS to simulate beam dynamics in accumulation rings and synchrotrons. The code is structured as a collection of external C++ modules for SuperCode, a high level interpreter shell developed at LLNL in the early 1990s. SuperCode is no longer actively supported and there has for some time been interest in replacing it by a modern scripting language, while preserving the feel of the original ORBIT program. In this paper, we describe a new version of ORBIT where the role of SuperCode is assumed by Python, a free, well-documented and widely supported object-oriented scripting language. We also compare PyORBIT to ORBIT from the standpoint of features, performance and future expandability

  20. Efficient Energy-Storage Concept

    Science.gov (United States)

    Brantley, L. W. J.; Rupp, C.

    1982-01-01

    Space-platform energy-storage and attitude-stabilization system utilizes variable moment of inertia of two masses attached to ends of retractable cable. System would be brought to its initial operating speed by gravity-gradient pumping. When fully developed, concept could be part of an orbiting solar-energy collection system. Energy would be temporarily stored in system then transmitted to Earth by microwaves or other method.

  1. Systems engineering studies of on-orbit assembly operation

    Science.gov (United States)

    Morgenthaler, George W.

    1991-01-01

    While the practice of construction has a long history, the underlying theory of construction is relatively young. Very little has been documented as to techniques of logistic support, construction planning, construction scheduling, construction testing, and inspection. The lack of 'systems approaches' to construction processes is certainly one of the most serious roadblocks to the construction of space structures. System engineering research efforts at CSC are aimed at developing concepts and tools which contribute to a systems theory of space construction. The research is also aimed at providing means for trade-offs of design parameters for other research areas in CSC. Systems engineering activity at CSC has divided space construction into the areas of orbital assembly, lunar base construction, interplanetary transport vehicle construction, and Mars base construction. A brief summary of recent results is given. Several models for 'launch-on-time' were developed. Launch-on-time is a critical concept to the assembly of such Earth-orbiting structures as the Space Station Freedom, and to planetary orbiters such as the Mars transfer vehicle. CSC has developed a launch vehicle selection model which uses linear programming to find optimal combinations of launch vehicles of various sizes (Atlas, Titan, Shuttles, HLLV's) to support SEI missions. Recently, the Center developed a cost trade-off model for studying on orbit assembly logistics. With this model it was determined that the most effective size of the HLLV would be in the range of 120 to 200 metric tons to LEO, which is consistent with the choices of General Stafford's Synthesis Group Report. A second-generation Dynamic Construction Activities Model ('DYCAM') process model has been under development, based on our past results in interruptability and our initial DYCAM model. This second-generation model is built on the paradigm of knowledge-based expert systems. It is aimed at providing answers to two questions: (1

  2. Orbital floor reconstruction using a tensor fascia lata sling after total maxillectomy.

    Science.gov (United States)

    Jung, Bok Ki; Yun, In Sik; Lee, Won Jai; Lew, Dae Hyun; Choi, Eun Chang; Lee, Dong Won

    2016-05-01

    Reconstruction after total maxillectomy with extensive orbital floor defects poses a significant challenge for the reconstruction. The aim of this study is to present the outcomes of orbital floor reconstruction using tensor fascia lata slings after total maxillectomy and to compare these results to orbital floor reconstruction using alloplastic implants. This was a retrospective analysis of 19 consecutive patients who underwent tumor resection with orbital floor removal for malignancies. Reconstructions were performed using either tensor fascia lata slings (Group A) or alloplastic implants (Group B). The early and late postoperative outcomes such as wound infection, plate exposure, ectropion, diplopia, and enophthalmos, were analyzed and compared between the two groups. Patients in group A had significantly less wound complication than in group B (p < 0.05). In group A, there were no early or late wound complications after the operation. However, in group B, five patients had infection, the plate was exposed in eight of fourteen patients, and three patients had enophthalmos. Eight patients in group B underwent reoperation to correct their complications. Reconstruction of the orbital floor with a tensor fascia lata sling offers reliable support to the globe and prevents the ophthalmic complications associated with loss of orbital support. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Acquisition/expulsion system for earth orbital propulsion system study. Volume 4: Flight test article

    Science.gov (United States)

    1973-01-01

    Two orbital test plans were prepared to verify one of the passive cryogenic storage tank/feedline candidate designs. One plan considered the orbital test article to be launched as a dedicated payload using an Atlas F burner launching configuration. The second plan proposed to launch the orbital test article as a secondary payload on the Titan E/Centaur proof flight. The secondary payload concept was pursued until January 1973, when work to build the hardware for this phase of the contract was terminated for lack of a sponsor for the flight. The dedicated payload launched on an Atlas F is described.

  4. Hepatocellular Carcinoma Metastasis to the Orbit in a Coinfected HIV+ HBV+ Patient Previously Treated with Orthotopic Liver Transplantation: A Case Report

    Directory of Open Access Journals (Sweden)

    S. Guerriero

    2011-01-01

    Full Text Available Hepatocellular carcinoma rarely metastasizes to the orbit. We report a 45-year-old male, HBV+, HIV+, with a past history of a liver transplant for ELSD (end-stage liver disease with hepatocellular carcinoma and recurrent HCC, who presented with proptosis and diplopia of the left eye. CT scans of the head revealed a large, irregular mass in the left orbit causing superior and lateral destruction of the orbital bone. Biopsy specimens of the orbital tumor showed features of metastatic foci of hepatocellular carcinoma. Only 16 other cases of HCC metastasis to the orbit have been described in literature, and this is the first case in a previously transplanted HIV+, HBV+ patient.

  5. TumorML: Concept and requirements of an in silico cancer modelling markup language.

    Science.gov (United States)

    Johnson, David; Cooper, Jonathan; McKeever, Steve

    2011-01-01

    This paper describes the initial groundwork carried out as part of the European Commission funded Transatlantic Tumor Model Repositories project, to develop a new markup language for computational cancer modelling, TumorML. In this paper we describe the motivations for such a language, arguing that current state-of-the-art biomodelling languages are not suited to the cancer modelling domain. We go on to describe the work that needs to be done to develop TumorML, the conceptual design, and a description of what existing markup languages will be used to compose the language specification.

  6. Orbital lymphoma: radiotherapy outcome and complications

    International Nuclear Information System (INIS)

    Stafford, Scott L.; Kozelsky, Timothy F.; Garrity, James A.; Kurtin, Paul J.; Leavitt, Jacqueline A.; Martenson, James A.; Habermann, Thomas M.

    2001-01-01

    Background and purpose: Orbital non-Hodgkin's lymphomas (NHL) have traditionally been treated with radiation. Forty-eight patients presenting with orbital NHL were treated with radiation and were evaluated for local control, overall survival, cause-specific survival, and complications. Materials and methods: Forty-five patients had low-grade and 3 patients had intermediate-grade histologic findings. Orbit-only disease occurred in 22 patients, the conjunctiva in 16, both in five, and lacrimal gland only in five. Patient age ranged from 35 to 94 years (median, 68). Ann Arbor stages were cIEA (34), cIIEA (six), cIIIEA (two), and cIVEA (six). Radiation doses ranged between 15 and 53.8 Gy (median, 27.5 Gy). Results: Follow-up ranged from 0.14 to 18.23 years (median, 5.35). Median overall survival and cause-specific survival were 6.5 and 15.5 years, respectively. Patients with clinical stage I or II disease had significantly better overall and cause-specific survival than patients with stage III or IV disease. Ten-year relapse-free survival in 41 patients with stage I or II disease was 66%. However, there was continued downward pressure on relapse-free survival out to 18 years. One local failure occurred. Twenty-five patients sustained acute complications. There were 17 minor and four major late complications. All major late complications occurred with doses more than 35 Gy. Conclusions: Excellent local control with radiation doses ranging from 15 to 30 Gy is achieved. Patients with stage I or II disease have better overall and cause-specific survival than patients with stage III or IV disease. Late relapse occurs in sites other than the treated orbit, even in patients with early-stage disease. Doses 35 Gy or higher result in significant late complications and are therefore not indicated for patients with low-grade tumors

  7. [Surgical treatment of diffuse adult orbital lymphangioma: two case studies].

    Science.gov (United States)

    Berthout, A; Jacomet, P V; Putterman, M; Galatoire, O; Morax, S

    2008-12-01

    Orbital lymphangioma is a rare vascular malformation; it is a benign but severe anomaly because of its infiltrative, diffuse, and hemorrhagic nature, and its high morbidity rate. Surgical resection is a real challenge on account of the intricate architecture of the lesion. The authors report their surgical experience concerning two cases of diffuse orbital lymphangioma whose diagnosis was established in adulthood and whose surgical treatment was successful. Two patients presented with adult orbital lymphangioma. Progression was slow during the first decade and then was quickly followed by complications: major exorbitism, compressive optic neuropathy, and corneal exposure. Neuroimaging showed a diffuse and cystic orbital malformation. Surgical resection was performed as completely as possible, in one case with a Krönlein orbitotomy and in the other case only via a conjunctive route. An aspirate drain was put in the orbit for 48 h so as to prevent dead spaces forming after resection, an essential risk factor of hemorrhagic or cystic recurrence. Systemic corticotherapy was administered for the 5 days following surgery. The resection was total in one case and subtotal in the other. The surgical follow-up was uneventful with an excellent aesthetic result and an improvement in visual acuity. After 12 months, no tumoral or hemorrhagic recurrence was noted. The surgical treatment of orbital lymphangiomas is challenging because of their infiltrative nature. In diffuse forms, a complete resection is rarely possible because of the risk of sacrificing visual function. In the two cases reported herein, the resection of the extraconal portion was complete, but the intraconal portion was completely removed only in one case. Using the aspirate drain, negative pressure was maintained in the orbital cavity, preventing the formation of chocolate cysts induced by surgery. Although the clinical result was very satisfying, long-term follow-up is necessary to evaluate recurrence

  8. VEGF-dependent mechanism of anti-angiogenic action of diamond nanoparticles in Glioblastoma Multiforme tumor

    DEFF Research Database (Denmark)

    Grodzik, M.; Sawosz, E.; Wierzbicki, M.

    2012-01-01

    Malignant gliomas are highly lethal cancers dependent on angiogenesis. The concept of treating tumors by inhibiting tumor angiogenesis was first articulated almost 30 years ago. Inhibition of tumor angiogenesis suppresses both tumor growth and metastasis. We determined the inhibition effect of di...

  9. Orbit Propagation and Determination of Low Earth Orbit Satellites

    Directory of Open Access Journals (Sweden)

    Ho-Nien Shou

    2014-01-01

    Full Text Available This paper represents orbit propagation and determination of low Earth orbit (LEO satellites. Satellite global positioning system (GPS configured receiver provides position and velocity measures by navigating filter to get the coordinates of the orbit propagation (OP. The main contradictions in real-time orbit which is determined by the problem are orbit positioning accuracy and the amount of calculating two indicators. This paper is dedicated to solving the problem of tradeoffs. To plan to use a nonlinear filtering method for immediate orbit tasks requires more precise satellite orbit state parameters in a short time. Although the traditional extended Kalman filter (EKF method is widely used, its linear approximation of the drawbacks in dealing with nonlinear problems was especially evident, without compromising Kalman filter (unscented Kalman Filter, UKF. As a new nonlinear estimation method, it is measured at the estimated measurements on more and more applications. This paper will be the first study on UKF microsatellites in LEO orbit in real time, trying to explore the real-time precision orbit determination techniques. Through the preliminary simulation results, they show that, based on orbit mission requirements and conditions using UKF, they can satisfy the positioning accuracy and compute two indicators.

  10. Rehabilitation of orbital cavity after orbital exenteration using polymethyl methacrylate orbital prosthesis

    Directory of Open Access Journals (Sweden)

    Sumeet Jain

    2016-01-01

    Full Text Available Squamous cell carcinoma of the eyelid is the second most common malignant neoplasm of the eye with the incidence of 0.09 and 2.42 cases/100 000 people. Orbital invasion is a rare complication but, if recognized early, can be treated effectively with exenteration. Although with advancements in technology such as computer-aided design and computer-aided manufacturing, material science, and retentive methods like implants, orbital prosthesis with stock ocular prosthesis made of methyl methacrylate retained by anatomic undercuts is quiet effective and should not be overlooked and forgotten. This clinical report describes prosthetic rehabilitation of two male patients with polymethyl methacrylate resin orbital prosthesis after orbital exenteration, for squamous cell carcinoma of the upper eyelid. The orbital prosthesis was sufficiently retained by hard and soft tissue undercuts without any complications. The patients using the prosthesis are quite satisfied with the cosmetic results and felt comfortable attending the social events.

  11. A brief introduction to molecular orbital theory of simple polyatomic molecules for undergraduate chemistry students

    Directory of Open Access Journals (Sweden)

    Ione M. Baibich

    2012-01-01

    Full Text Available A simple, four-step method for better introducing undergraduate students to the fundamentals of molecular orbital (MO theory of the polyatomic molecules H2O, NH3, BH3 and SiH4 using group theory is reported. These molecules serve to illustrate the concept of ligand group orbitals (LGOs and subsequent construction of MO energy diagrams on the basis of molecular symmetry requirements.

  12. CT and MR imaging of primary tumors of the masticator space

    International Nuclear Information System (INIS)

    Aspestrand, F.; Boysen, M.

    1992-01-01

    A retrospective study of CT and MR examinations in 14 patients with benign and malignant tumors originating in the masticator space is presented. At presentation, 12 patients revealed tumor extension to adjacent regions and spaces. Perineutral tumor spread along trigeminal nerve branches to the cavernous sinus and orbits was combined with facial pain, and/or numbness, ophthalmoplegia, and exophthalmus. Detailed analysis of tumor growth and spread, enhancement and signal features at CT and MR imaging indicated that tumor histology was, with a few exceptions, nonspecific. More extensive growth and bone destruction was noted only among malignant tumors. MR imaging was found superior to CT in delineating tumor extension due to better soft tissue contrast resolution and multiplanar imaging. Posttreatment examinations were available in 11 patients and showed long-standing regional edema of the adjacent temporal lobe and masticator muscles in 4 out of 5 patients without clinical evidence of tumor. In 6 patients, CT and MR features were found almost unchanged with only small size differences after various forms of treatment. (orig.)

  13. ORBITAL INJURIES

    Directory of Open Access Journals (Sweden)

    Andrej Kansky

    2002-12-01

    Full Text Available Background. Orbit is involved in 40% of all facial fractures. There is considerable variety in severity, ranging from simple nondisplaced to complex comminuted fractures. Complex comminuted fractures (up to 20% are responsible for the majority of complications and unfavorable results. Orbital fractures are classified as internal orbital fractures, zygomatico-orbital fractures, naso-orbito-ethmoidal fractures and combined fractures. The ophtalmic sequelae of midfacial fractures are usually edema and ecchymosis of the soft tissues, subconjuctival hemorrhage, diplopia, iritis, retinal edema, ptosis, enophthalmos, ocular muscle paresis, mechanical restriction of ocular movement and nasolacrimal disturbances. More severe injuries such as optic nerve trauma and retinal detachments have also been reported. Within the wide range of orbital fractures small group of complex fractures causes most of the sequelae. Therefore identification of severe injuries and adequate treatment is of major importance. The introduction of craniofacial techniques made possible a wide exposure even of large orbital wall defects and their reconstruction by bone grafts. In spite of significant progress, repair of complex orbital wall defects remains a problem even for the experienced surgeons.Results. In 1999 121 facial injuries were treated at our department (Clinical Centre Ljubljana Dept. Of Maxillofacial and Oral Surgery. Orbit was involved in 65% of cases. Isolated inner orbital fractures presented 4% of all fractures. 17 (14% complex cases were treated, 5 of them being NOE, 5 orbital (frame and inner walls, 3 zygomatico-orbital, 2 FNO and 2 maxillo-orbital fractures.Conclusions. Final result of the surgical treatment depends on severity of maxillofacial trauma. Complex comminuted fractures are responsable for most of the unfavorable results and ocular function is often permanently damaged (up to 75% in these fractures.

  14. Orbital

    OpenAIRE

    Yourshaw, Matthew Stephen

    2017-01-01

    Orbital is a virtual reality gaming experience designed to explore the use of traditional narrative structure to enhance immersion in virtual reality. The story structure of Orbital was developed based on the developmental steps of 'The Hero's Journey,' a narrative pattern identified by Joseph Campbell. Using this standard narrative pattern, Orbital is capable of immersing the player quickly and completely for the entirety of play time. MFA

  15. DRAGONS-A Micrometeoroid and Orbital Debris Impact Sensor on the ISS

    Science.gov (United States)

    Liou, J.-C.; Hamilton, J.; Liolios, S.; Anderson, C.; Sadilek, A.; Corsaro, R.; Giovane, F.; Burchell, M.

    2015-01-01

    The Debris Resistive/Acoustic Grid Orbital Navy-NASA Sensor (DRAGONS) is intended to be a large area impact sensor for in situ measurements of micrometeoroids and orbital debris (MMOD) in the sub-millimeter to millimeter size regime in the near Earth space environment. These MMOD particles are too small to be detected by ground-based radars and optical telescopes, but still large enough to be a serious threat to human space activities and robotic missions in the low Earth orbit (LEO) region. The nominal detection area of DRAGONS is 1 sq m, consisting of four 0.5 m × 0.5 m independent panels, but the dimensions of the panels can easily be modified to accommodate different payload constraints. The approach of the DRAGONS design is to combine three particle impact detection concepts to maximize information that can be extracted from each detected impact. The first is a resistive grid consisting of 75-micrometer-wide resistive lines, coated in parallel and separated by 75 micrometer gaps on a 25-micrometer thin film. When a particle a few hundred micrometers or larger strikes the grid, it would penetrate the film and sever some resistive lines. The size of the damage area can be estimated from the increased resistance. The second concept is based on polyvinylidene fluoride (PVDF) acoustic impact sensors. Multiple PVDF sensors are attached to the thin film to provide the impact timing information. From the different signal arrival times at different acoustic sensors, the impact location can be calculated via triangulation algorithms. The third concept employs a dual-layer film system where a second 25-micrometer film is placed 15 cm behind the resistive-grid film. Multiple PVDF acoustic sensors are also attached to the second film. The combination of impact timing and location information from the two films allows for direct measurements of the impact direction and speed. The DRAGONS technology development has been funded by several NASA organizations since 2002, first

  16. The Habitable Zone and Extreme Planetary Orbits

    OpenAIRE

    Kane, Stephen R.; Gelino, Dawn M.

    2012-01-01

    The habitable zone for a given star describes the range of circumstellar distances from the star within which a planet could have liquid water on its surface, which depends upon the stellar properties. Here we describe the development of the habitable zone concept, its application to our own solar system, and its subsequent application to exoplanetary systems. We further apply this to planets in extreme eccentric orbits and show how they may still retain life-bearing properties depending upon...

  17. From orbital debris capture systems through internal combustion engines on Mars

    Science.gov (United States)

    1991-01-01

    The investigation and conceptualization of an orbital debris collector was the primary area of design. In addition, an alternate structural design for Space Station Freedom and systems supporting resource utilization at Mars and the moon were studied. Hardware for production of oxygen from simulate Mars atmosphere was modified to permit more reliable operation at low pressures (down to 10 mb). An internal combustion engine was altered to study how Mars atmosphere could be used as a diluent to control combustion temperatures and avoid excess Mars propellant production requirements that would result from either methane-rich or oxygen-rich, methane-oxygen combustion. An elastic loop traction system that could be used for lunar construction vehicles was refined to permit testing. A parabolic heat rejection radiator system was designed and built to determine whether it was capable of increasing heat rejection rates during lunar daytime operation. In addition, an alternate space station truss design, utilizing a pre-integrated concept, was studied and found to reduce estimate extravehicular activity (EVA) time and increase the structural integrity when compared to the original Warren truss concept. An orbital-debris-capturing spacecraft design which could be mated with the Orbital Maneuvering Vehicle was studied. The design identified Soviet C-1B boosters as the best targets of opportunity in Earth orbits between an altitude of 900 km and 1100 km and at an inclination of 82.9 deg. A dual robot pallet, which could be spun to match the tumbling rate of the C-1B booster, was developed as the conceptual design.

  18. ULTRASOUND AND COMPUTED TOMOGRAPHIC DIAGNOSIS OF OPTIC NERVE TUMORS

    Directory of Open Access Journals (Sweden)

    S. V. Saakyan

    2012-01-01

    Full Text Available A comprehensive examination was made in 93 patients, including 18 children, with tumors of the optic nerve (ON. Duplex ultrasound scanning was performed in 39 patients, of them there were 11 patients with ON gliomas and 28 with ON meningiomas. The specific computed tomographic and echographic signs of ON glioma and meningiomas were detected. The studies have shown that duplex ultrasound scanning and structural computed tomography of orbital sockets are highly informative complementary imaging procedures for ON tumors, which permits one to make their correct diagnosis, to specify surgical volume, and to plan adequate treatment.

  19. Orbit Functions

    Directory of Open Access Journals (Sweden)

    Anatoliy Klimyk

    2006-01-01

    Full Text Available In the paper, properties of orbit functions are reviewed and further developed. Orbit functions on the Euclidean space E_n are symmetrized exponential functions. The symmetrization is fulfilled by a Weyl group corresponding to a Coxeter-Dynkin diagram. Properties of such functions will be described. An orbit function is the contribution to an irreducible character of a compact semisimple Lie group G of rank n from one of its Weyl group orbits. It is shown that values of orbit functions are repeated on copies of the fundamental domain F of the affine Weyl group (determined by the initial Weyl group in the entire Euclidean space E_n. Orbit functions are solutions of the corresponding Laplace equation in E_n, satisfying the Neumann condition on the boundary of F. Orbit functions determine a symmetrized Fourier transform and a transform on a finite set of points.

  20. The Chocolate Shop and Atomic Orbitals: A New Atomic Model Created by High School Students to Teach Elementary Students

    Science.gov (United States)

    Liguori, Lucia

    2014-01-01

    Atomic orbital theory is a difficult subject for many high school and beginning undergraduate students, as it includes mathematical concepts not yet covered in the school curriculum. Moreover, it requires certain ability for abstraction and imagination. A new atomic orbital model "the chocolate shop" created "by" students…

  1. Proton radiation therapy for retinoblastoma: Comparison of various intraocular tumor locations and beam arrangements

    International Nuclear Information System (INIS)

    Krengli, Marco; Hug, Eugen B.; Adams, Judy A.; Smith, Alfred R.; Tarbell, Nancy J.; Munzenrider, John E.

    2005-01-01

    Purpose: To study the optimization of proton beam arrangements for various intraocular tumor locations; and to correlate isodose distributions with various target and nontarget structures. Methods and materials: We considered posterior-central, nasal, and temporal tumor locations, with straight, intrarotated, or extrarotated eye positions. Doses of 46 cobalt grey equivalent (CGE) to gross tumor volume (GTV) and 40 CGE to clinical target volume (CTV) (2 CGE per fraction) were assumed. Using three-dimensional planning, we compared isodose distributions for lateral, anterolateral oblique, and anteromedial oblique beams and dose-volume histograms of CTVs, GTVs, lens, lacrimal gland, bony orbit, and soft tissues. Results: All beam arrangements fully covered GTVs and CTVs with optimal lens sparing. Only 15% of orbital bone received doses ≥20 CGE with a lateral beam, with 20-26 CGE delivered to two of three growth centers. The anterolateral oblique approach with an intrarotated eye resulted in additional reduction of bony volume and exposure of only one growth center. No appreciable dose was delivered to the contralateral eye, brain tissue, or pituitary gland. Conclusions: Proton therapy achieved homogeneous target coverage with true lens sparing. Doses to orbit structures, including bony growth centers, were minimized with different beam arrangements and eye positions. Proton therapy could reduce the risks of second malignancy and cosmetic and functional sequelae

  2. Spin–orbit coupling in actinide cations

    DEFF Research Database (Denmark)

    Bagus, Paul S.; Ilton, Eugene S.; Martin, Richard L.

    2012-01-01

    The limiting case of Russell–Saunders coupling, which leads to a maximum spin alignment for the open shell electrons, usually explains the properties of high spin ionic crystals with transition metals. For actinide compounds, the spin–orbit splitting is large enough to cause a significantly reduced...... spin alignment. Novel concepts are used to explain the dependence of the spin alignment on the 5f shell occupation. We present evidence that the XPS of ionic actinide materials may provide direct information about the angular momentum coupling within the 5f shell....

  3. Ground Contact Analysis for Korea’s Fictitious Lunar Orbiter Mission

    Directory of Open Access Journals (Sweden)

    Young-Joo Song

    2013-12-01

    Full Text Available In this research, the ground contact opportunity for the fictitious low lunar orbiter is analyzed to prepare for a future Korean lunar orbiter mission. The ground contact opportunity is basically derived from geometrical relations between the typical ground stations at the Earth, the relative positions of the Earth and Moon, and finally, the lunar orbiter itself. Both the cut-off angle and the orbiter’s Line of Sight (LOS conditions (weather orbiter is located at near or far side of the Moon seen from the Earth are considered to determine the ground contact opportunities. Four KOMPSAT Ground Stations (KGSs are assumed to be Korea’s future Near Earth Networks (NENs to support lunar missions, and world-wide separated Deep Space Networks (DSNs are also included during the contact availability analysis. As a result, it is concluded that about 138 times of contact will be made between the orbiter and the Daejeon station during 27.3 days of prediction time span. If these contact times are converted into contact duration, the duration is found to be about 8.55 days, about 31.31% of 27.3 days. It is discovered that selected four KGSs cannot provide continuous tracking of the lunar orbiter, meaning that international collaboration is necessary to track Korea’s future lunar orbiter effectively. Possible combinations of world-wide separated DSNs are also suggested to compensate for the lack of contact availability with only four KGSs, as with primary and backup station concepts. The provided algorithm can be easily modified to support any type of orbit around the Moon, and therefore, the presented results could aid further progress in the design field of Korea’s lunar orbiter missions.

  4. [Undifferentiated soft tissue tumor with rhabdoid phenotype (extra-renal rhabdoid tumor). Report of a congenital case associated with medulloblastoma in a brother].

    Science.gov (United States)

    Costes, V; Medioni, D; Durand, L; Sarran, N; Marguerite, G; Baldet, P

    1997-03-01

    We report a case of congenital cervical rhabdoid tumor with association of a medulloblastoma in a brother. The immunohistochemical features of this tumor are compatible with a neuroectodermal differentiation (MIC 2+, Leu 7+). Extrarenal rhabdoid tumors share a common morphology but do not represent a single entity with only one histogenesis. Most of them are now considered to be of neuroectodermal origin. In our case, the association with a medulloblastoma in a brother seems to confirm this concept.

  5. Attitude control analysis of tethered de-orbiting

    Science.gov (United States)

    Peters, T. V.; Briz Valero, José Francisco; Escorial Olmos, Diego; Lappas, V.; Jakowski, P.; Gray, I.; Tsourdos, A.; Schaub, H.; Biesbroek, R.

    2018-05-01

    The increase of satellites and rocket upper stages in low earth orbit (LEO) has also increased substantially the danger of collisions in space. Studies have shown that the problem will continue to grow unless a number of debris are removed every year. A typical active debris removal (ADR) mission scenario includes launching an active spacecraft (chaser) which will rendezvous with the inactive target (debris), capture the debris and eventually deorbit both satellites. Many concepts for the capture of the debris while keeping a connection via a tether, between the target and chaser have been investigated, including harpoons, nets, grapples and robotic arms. The paper provides an analysis on the attitude control behaviour for a tethered de-orbiting mission based on the ESA e.Deorbit reference mission, where Envisat is the debris target to be captured by a chaser using a net which is connected to the chaser with a tether. The paper provides novel insight on the feasibility of tethered de-orbiting for the various mission phases such as stabilization after capture, de-orbit burn (plus stabilization), stabilization during atmospheric pass, highlighting the importance of various critical mission parameters such as the tether material. It is shown that the selection of the appropriate tether material while using simple controllers can reduce the effort needed for tethered deorbiting and can safely control the attitude of the debris/chaser connected with a tether, without the danger of a collision.

  6. The new WHO 2016 classification of brain tumors-what neurosurgeons need to know.

    Science.gov (United States)

    Banan, Rouzbeh; Hartmann, Christian

    2017-03-01

    The understanding of molecular alterations of tumors has severely changed the concept of classification in all fields of pathology. The availability of high-throughput technologies such as next-generation sequencing allows for a much more precise definition of tumor entities. Also in the field of brain tumors a dramatic increase of knowledge has occurred over the last years partially calling into question the purely morphologically based concepts that were used as exclusive defining criteria in the WHO 2007 classification. Review of the WHO 2016 classification of brain tumors as well as a search and review of publications in the literature relevant for brain tumor classification from 2007 up to now. The idea of incorporating the molecular features in classifying tumors of the central nervous system led the authors of the new WHO 2016 classification to encounter inevitable conceptual problems, particularly with respect to linking morphology to molecular alterations. As a solution they introduced the concept of a "layered diagnosis" to the classification of brain tumors that still allows at a lower level a purely morphologically based diagnosis while partially forcing the incorporation of molecular characteristics for an "integrated diagnosis" at the highest diagnostic level. In this context the broad availability of molecular assays was debated. On the one hand molecular antibodies specifically targeting mutated proteins should be available in nearly all neuropathological laboratories. On the other hand, different high-throughput assays are accessible only in few first-world neuropathological institutions. As examples oligodendrogliomas are now primarily defined by molecular characteristics since the required assays are generally established, whereas molecular grouping of ependymomas, found to clearly outperform morphologically based tumor interpretation, was rejected from inclusion in the WHO 2016 classification because the required assays are currently only

  7. What is a pediatric tumor?

    Directory of Open Access Journals (Sweden)

    Mora J

    2012-11-01

    Full Text Available Jaume Mora1,21Department of Oncology, 2Developmental Tumor Biology Laboratory, Hospital Sant Joan de Deu, Fundacio Sant Joan de Deu, Barcelona, SpainAbstract: Working together with medical oncologists, the question of whether a Ewing sarcoma in a 25-year-old is a pediatric tumor comes up repeatedly. Like Ewing's, some tumors present characteristically at ages that cross over what has been set as the definition of pediatrics (15 years, 18 years, or 21 years?. Pediatric oncology textbooks, surprisingly, do not address the subject of defining a pediatric tumor. They all begin with an epidemiology chapter defining the types of tumors appearing at distinct stages of childhood, adolescence, and young adulthood. Describing the epidemiology of tumors in relation to age, it becomes clear that the disease is related to the phenomenon of aging. The question, however, remains: is there a biological definition of what pediatric age is? And if so, will tumors occurring during this period of life have anything to do with such biological definition? With the aim of finding an objective definition, the fundamental concepts of what defines "pediatrics" was reviewed and then the major features of tumors arising during development were analyzed. The tumors were explored from the perspective of a host immersed in the normal process of growth and development. This physiological process, from pluripotential and undifferentiated cells, makes possible the differentiation, maturation, organization, and function of tissues, organs, and apparatus. A biological definition of pediatric tumors and the infancy–childhood–puberty classification of developmental tumors according to the infancy–childhood–puberty model of normal human development are proposed.Keywords: growth and development, pediatric tumor, infant, childhood and adolescence, pubertal tumors

  8. [Precision Oncology and "Molecular Tumor Boards" - Concepts, Chances and Challenges].

    Science.gov (United States)

    Holch, Julian Walter; Westphalen, Christoph Benedikt; Hiddemann, Wolfgang; Heinemann, Volker; Jung, Andreas; Metzeler, Klaus Hans

    2017-11-01

    Recent developments in genomics allow a more and more comprehensive genetic analysis of human malignancies, and have sparked hopes that this will contribute to the development of novel targeted, effective and well-tolerated therapies.While targeted therapies have improved the prognosis of many cancer patients with certain tumor types, "precision oncology" also brings along new challenges. Highly personalized treatment strategies require new strategies for clinical trials and translation into routine clinical practice. We review the current technical approaches for "universal genetic testing" in cancer, and potential pitfalls in the interpretation of such data. We then provide an overview of the available evidence supporting treatment strategies based on extended genetic analysis. Based on the available data, we conclude that "precision oncology" approaches that go beyond the current standard of care should be pursued within the framework of an interdisciplinary "molecular tumor board", and preferably within clinical trials. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Evaluation of Three Cases Using a Novel Titanium Mesh System-Skull-Fit with Orbital Wall (Skull-Fit WOW)-For Cranial Base Reconstructions.

    Science.gov (United States)

    Hattori, Noriko; Nakajima, Hideo; Tamada, Ikkei; Sakamoto, Yoshiaki; Ohira, Takayuki; Yoshida, Kazunari; Kawase, Takeshi; Kishi, Kazuo

    2011-09-01

    Cranial base reconstructions associated with tumor resections around the orbital wall often require that both the upper and lateral orbital walls be reconstructed during a single procedure. Previously, we used titanium mesh plates that were preoperatively fabricated based on three-dimensional models. Although these plates are precise and do not increase the probability of infection, we still had to use autologous bones to reconstruct the orbital walls. Recently, we developed a new titanium mesh plate-called Skull-Fit(®)-with orbital wall (Skull-Fit WOW(®)), enabling us to reconstruct the cranial base and orbital walls without bone grafts. Here, we report on three reconstruction cases in which the novel titanium mesh-orbital wall system was used. In all three cases, the customized titanium mesh system performed satisfactorily with little, if any, complications.

  10. Treatment Effects and Sequelae of Radiation Therapy for Orbital Mucosa-Associated Lymphoid Tissue Lymphoma

    International Nuclear Information System (INIS)

    Hata, Masaharu; Omura, Motoko; Koike, Izumi; Tomita, Naoto; Iijima, Yasuhito; Tayama, Yoshibumi; Odagiri, Kazumasa; Minagawa, Yumiko; Ogino, Ichiro; Inoue, Tomio

    2011-01-01

    Purpose: Among extranodal lymphomas, orbital mucosa-associated lymphoid tissue (MALT) lymphoma is a relatively rare presentation. We performed a review to ascertain treatment efficacy and toxicity of radiation therapy for orbital MALT lymphoma. We also evaluated changes in visual acuity after irradiation. Methods and Materials: Thirty patients with orbital MALT lymphoma underwent radiation therapy with curative intent. Clinical stages at diagnosis were stage I E A in 29 patients and stage II E A in 1 patient. Total doses of 28.8 to 45.8 Gy (median, 30 Gy) in 15 to 26 fractions (median, 16 fractions) were delivered to the tumors. Results: All irradiated tumors were controlled during the follow-up period of 2 to 157 months (median, 35 months) after treatment. Two patients had relapses that arose in the cervical lymph node and the ipsilateral palpebral conjunctiva outside the radiation field at 15 and 67 months after treatment, respectively. The 5-year local progression-free and relapse-free rates were 100% and 96%, respectively. All 30 patients are presently alive; the overall and relapse-free survival rates at 5 years were 100% and 96%, respectively. Although 5 patients developed cataracts of grade 2 at 8 to 45 months after irradiation, they underwent intraocular lens implantation, and their eyesight recovered. Additionally, there was no marked deterioration in the visual acuity of patients due to irradiation, with the exception of cataracts. No therapy-related toxicity of grade 3 or greater was observed. Conclusions: Radiation therapy was effective and safe for patients with orbital MALT lymphoma. Although some patients developed cataracts after irradiation, visual acuity was well preserved.

  11. Treatment Effects and Sequelae of Radiation Therapy for Orbital Mucosa-Associated Lymphoid Tissue Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Hata, Masaharu, E-mail: mhata@syd.odn.ne.jp [Department of Radiology, Yokohama City University Graduate School of Medicine, Yokohama, Kanagawa (Japan); Omura, Motoko; Koike, Izumi [Department of Radiology, Yokohama City University Graduate School of Medicine, Yokohama, Kanagawa (Japan); Tomita, Naoto [Department of Internal Medicine and Clinical Immunology, Yokohama City University Graduate School of Medicine, Yokohama, Kanagawa (Japan); Iijima, Yasuhito [Department of Ophthalmology, Yokohama City University Graduate School of Medicine, Yokohama, Kanagawa (Japan); Tayama, Yoshibumi; Odagiri, Kazumasa; Minagawa, Yumiko [Department of Radiology, Yokohama City University Graduate School of Medicine, Yokohama, Kanagawa (Japan); Ogino, Ichiro [Department of Radiation Oncology, Yokohama City University Medical Center, Yokohama, Kanagawa (Japan); Inoue, Tomio [Department of Radiology, Yokohama City University Graduate School of Medicine, Yokohama, Kanagawa (Japan)

    2011-12-01

    Purpose: Among extranodal lymphomas, orbital mucosa-associated lymphoid tissue (MALT) lymphoma is a relatively rare presentation. We performed a review to ascertain treatment efficacy and toxicity of radiation therapy for orbital MALT lymphoma. We also evaluated changes in visual acuity after irradiation. Methods and Materials: Thirty patients with orbital MALT lymphoma underwent radiation therapy with curative intent. Clinical stages at diagnosis were stage I{sub E}A in 29 patients and stage II{sub E}A in 1 patient. Total doses of 28.8 to 45.8 Gy (median, 30 Gy) in 15 to 26 fractions (median, 16 fractions) were delivered to the tumors. Results: All irradiated tumors were controlled during the follow-up period of 2 to 157 months (median, 35 months) after treatment. Two patients had relapses that arose in the cervical lymph node and the ipsilateral palpebral conjunctiva outside the radiation field at 15 and 67 months after treatment, respectively. The 5-year local progression-free and relapse-free rates were 100% and 96%, respectively. All 30 patients are presently alive; the overall and relapse-free survival rates at 5 years were 100% and 96%, respectively. Although 5 patients developed cataracts of grade 2 at 8 to 45 months after irradiation, they underwent intraocular lens implantation, and their eyesight recovered. Additionally, there was no marked deterioration in the visual acuity of patients due to irradiation, with the exception of cataracts. No therapy-related toxicity of grade 3 or greater was observed. Conclusions: Radiation therapy was effective and safe for patients with orbital MALT lymphoma. Although some patients developed cataracts after irradiation, visual acuity was well preserved.

  12. Active Debris Removal mission design in Low Earth Orbit

    Science.gov (United States)

    Martin, Th.; Pérot, E.; Desjean, M.-Ch.; Bitetti, L.

    2013-03-01

    Active Debris Removal (ADR) aims at removing large sized intact objects ― defunct satellites, rocket upper-stages ― from space crowded regions. Why? Because they constitute the main source of the long-term debris environment deterioration caused by possible future collisions with fragments and worse still with other intact but uncontrolled objects. In order to limit the growth of the orbital debris population in the future (referred to as the Kessler syndrome), it is now highly recommended to carry out such ADR missions, together with the mitigation measures already adopted by national agencies (such as postmission disposal). At the French Space Agency, CNES, and in the frame of advanced studies, the design of such an ADR mission in Low Earth Orbit (LEO) is under evaluation. A two-step preliminary approach has been envisaged. First, a reconnaissance mission based on a small demonstrator (˜500 kg) rendezvousing with several targets (observation and in-flight qualification testing). Secondly, an ADR mission based on a larger vehicle (inherited from the Orbital Transfer Vehicle (OTV) concept) being able to capture and deorbit several preselected targets by attaching a propulsive kit to these targets. This paper presents a flight dynamics level tradeoff analysis between different vehicle and mission concepts as well as target disposal options. The delta-velocity, times, and masses required to transfer, rendezvous with targets and deorbit are assessed for some propelled systems and propellant less options. Total mass budgets are then derived for two end-to-end study cases corresponding to the reconnaissance and ADR missions mentioned above.

  13. Space-to-Space Power Beaming Enabling High Performance Rapid Geocentric Orbit Transfer

    Science.gov (United States)

    Dankanich, John W.; Vassallo, Corinne; Tadge, Megan

    2015-01-01

    The use of electric propulsion is more prevalent than ever, with industry pursuing all electric orbit transfers. Electric propulsion provides high mass utilization through efficient propellant transfer. However, the transfer times become detrimental as the delta V transitions from near-impulsive to low-thrust. Increasing power and therefore thrust has diminishing returns as the increasing mass of the power system limits the potential acceleration of the spacecraft. By using space-to-space power beaming, the power system can be decoupled from the spacecraft and allow significantly higher spacecraft alpha (W/kg) and therefore enable significantly higher accelerations while maintaining high performance. This project assesses the efficacy of space-to-space power beaming to enable rapid orbit transfer while maintaining high mass utilization. Concept assessment requires integrated techniques for low-thrust orbit transfer steering laws, efficient large-scale rectenna systems, and satellite constellation configuration optimization. This project includes the development of an integrated tool with implementation of IPOPT, Q-Law, and power-beaming models. The results highlight the viability of the concept, limits and paths to infusion, and comparison to state-of-the-art capabilities. The results indicate the viability of power beaming for what may be the only approach for achieving the desired transit times with high specific impulse.

  14. Soy isoflavone exposure through all life stages accelerates 17β-estradiol-induced mammary tumor onset and growth, yet reduces tumor burden, in ACI rats.

    Science.gov (United States)

    Möller, Frank Josef; Pemp, Daniela; Soukup, Sebastian T; Wende, Kathleen; Zhang, Xiajie; Zierau, Oliver; Muders, Michael H; Bosland, Maarten C; Kulling, Sabine E; Lehmann, Leane; Vollmer, Günter

    2016-08-01

    There is an ongoing debate whether the intake of soy-derived isoflavones (sISO) mediates beneficial or adverse effects with regard to breast cancer risk. Therefore, we investigated whether nutritional exposure to a sISO-enriched diet from conception until adulthood impacts on 17β-estradiol (E2)-induced carcinogenesis in the rat mammary gland (MG). August-Copenhagen-Irish (ACI) rats were exposed to dietary sISO from conception until postnatal day 285. Silastic tubes containing E2 were used to induce MG tumorigenesis. Body weight, food intake, and tumor growth were recorded weekly. At necropsy, the number, position, size, and weight of each tumor were determined. Plasma samples underwent sISO analysis, and the morphology of MG was analyzed. Tumor incidence and multiplicity were reduced by 20 and 56 %, respectively, in the sISO-exposed rats compared to the control rats. Time-to-tumor onset was shortened from 25 to 20 weeks, and larger tumors developed in the sISO-exposed rats. The histological phenotype of the MG tumors was independent of the sISO diet received, and it included both comedo and cribriform phenotypes. Morphological analyses of the whole-mounted MGs also showed no diet-dependent differences. Lifelong exposure to sISO reduced the overall incidence of MG carcinomas in ACI rats, although the time-to-tumor was significantly shortened.

  15. Inflammatory myofibroblastic tumor

    Directory of Open Access Journals (Sweden)

    Sangeeta Palaskar

    2011-01-01

    Full Text Available Inflammatory myofibroblastic tumor is an uncommon lesion of unknown cause. It encompasses a spectrum of myofibroblastic proliferation along with varying amount of inflammatory infiltrate. A number of terms have been applied to the lesion, namely, inflammatory pseudotumor, fibrous xanthoma, plasma cell granuloma, pseudosarcoma, lymphoid hamartoma, myxoid hamartoma, inflammatory myofibrohistiocytic proliferation, benign myofibroblatoma, and most recently, inflammatory myofibroblastic tumor. The diverse nomenclature is mostly descriptive and reflects the uncertainty regarding true biologic nature of these lesions. Recently, the concept of this lesion being reactive has been challenged based on the clinical demonstration of recurrences and metastasis and cytogenetic evidence of acquired clonal chromosomal abnormalities. We hereby report a case of inflammatory pseudotumor and review its inflammatory versus neoplastic behavior.

  16. ERS orbit control

    Science.gov (United States)

    Rosengren, Mats

    1991-12-01

    The European remote sensing mission orbit control is addressed. For the commissioning phase, the orbit is defined by the following requirements: Sun synchronous, local time of descending node 10:30; three days repeat cycle with 43 orbital revolutions; overhead Venice tower (12.508206 deg east, 45.314222 deg north). The launch, maneuvers for the initial acquisition of the operational orbit, orbit maintenance maneuvers, evaluation of the orbit control, and the drift of the inclination are summarized.

  17. Computed tomography and histopathological findings in pseudotumors of the orbit

    International Nuclear Information System (INIS)

    Ishibashi, Yasuhiko; Watanabe, Takao; Yoshimoto, Takashi; Suzuki, Jiro

    1981-01-01

    The CT scan findings of 4 cases of orbital tumor, in which transcranial orbital decompression was performed because of no improvement by medication, were reported. The first case was a 71-year-old female with exophthalmos, decreased vision and ocular movement disturbance of the left eye. CT scan demonstrated an abnormal high density area in the left retrobulbar region with a thickened medial rectal muscle. Specimens were taken from a thickened medial rectal muscle. The histological examination revealed angitis. The second case was a 38-year-old female with exophthalmos, blepharoptosis, chemosis, decreased vision and ocular movement disturbance of the left eye. CT scan showed exophthalmos of the left eye, but no focal abnormality. Specimens were taken from fatty tissue-in the left retrobulbar region. The histological examination revealed no abnormal inflammatory changes. The third case was a 37-year-old female with orbital pain, exophthalmos and ocular movement disturbance of the right eye. CT scan demonstrated a growing abnormal high density area in the right retrobulbar region. Specimens were taken from the abnormal tissue in the right retrobulbar region. The histological examination revealed inflammatory changes of muscle and nerve. The forth case was a 61-year-old male with diplopia and exophthalmos. CT scan demonstrated an abnormal high density area in the left retrobulbar region. Specimens were taken from an abnormal tissue in the left retrobulbar region lying against the lateral wall of the orbit. The histological examination revealed severe infiltrations with lymphocytes and plasma cells. Transcranial orbital decompression improved the exophthalmos and ocular movement in all cases. (author)

  18. Computed tomography and histopathological findings in pseudotumors of the orbit

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Y.; Watanabe, T.; Yoshimoto, T.; Suzuki, J. (Tohoku Univ., Sendai (Japan). School of Medicine)

    1981-09-01

    The CT scan findings of 4 cases of orbital tumor, in which transcranial orbital decompression was performed because of no improvement by medication, were reported. The first case was a 71-year-old female with exophthalmos, decreased vision and ocular movement disturbance of the left eye. CT scan demonstrated an abnormal high density area in the left retrobulbar region with a thickened medial rectal muscle. Specimens were taken from a thickened medial rectal muscle. The histological examination revealed angitis. The second case was a 38-year-old female with exophthalmos, blepharoptosis, chemosis, decreased vision and ocular movement disturbance of the left eye. CT scan showed exophthalmos of the left eye, but no focal abnormality. Specimens were taken from fatty tissue in the left retrobulbar region. The histological examination revealed no abnormal inflammatory changes. The third case was a 37-year-old female with orbital pain, exophthalmos and ocular movement disturbance of the right eye. CT scan demonstrated a growing abnormal high density area in the right retrobulbar region. Specimens were taken from the abnormal tissue in the right retrobulbar region. The histological examination revealed inflammatory changes of muscle and nerve. The forth case was a 61-year-old male with diplopia and exophthalmos. CT scan demonstrated an abnormal high density area in the left retrobulbar region. Specimens were taken from an abnormal tissue in the left retrobulbar region lying against the lateral wall of the orbit. The histological examination revealed severe infiltrations with lymphocytes and plasma cells. Transcranial orbital decompression improved the exophthalmos and ocular movement in all cases.

  19. Remodeling of Tumor Stroma and Response to Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, Anna; Ganss, Ruth, E-mail: ganss@waimr.uwa.edu.au [Western Australian Institute for Medical Research, Centre for Medical Research, University of Western Australia, Perth 6000 (Australia)

    2012-03-27

    Solid tumors are intrinsically resistant to therapy. Cancer progression occurs when tumor cells orchestrate responses from diverse stromal cell types such as blood vessels and their support cells, inflammatory cells, and fibroblasts; these cells collectively form the tumor microenvironment and provide direct support for tumor growth, but also evasion from cytotoxic, immune and radiation therapies. An indirect result of abnormal and leaky blood vessels in solid tumors is high interstitial fluid pressure, which reduces drug penetration, but also creates a hypoxic environment that further augments tumor cell growth and metastatic spread. Importantly however, studies during the last decade have shown that the tumor stroma, including the vasculature, can be modulated, or re-educated, to allow better delivery of chemotherapeutic drugs or enhance the efficiency of active immune therapy. Such remodeling of the tumor stroma using genetic, pharmacological and other therapeutic approaches not only enhances selective access into tumors but also reduces toxic side effects. This review focuses on recent novel concepts to modulate tumor stroma and thus locally increase therapeutic efficacy.

  20. Remodeling of Tumor Stroma and Response to Therapy

    International Nuclear Information System (INIS)

    Johansson, Anna; Ganss, Ruth

    2012-01-01

    Solid tumors are intrinsically resistant to therapy. Cancer progression occurs when tumor cells orchestrate responses from diverse stromal cell types such as blood vessels and their support cells, inflammatory cells, and fibroblasts; these cells collectively form the tumor microenvironment and provide direct support for tumor growth, but also evasion from cytotoxic, immune and radiation therapies. An indirect result of abnormal and leaky blood vessels in solid tumors is high interstitial fluid pressure, which reduces drug penetration, but also creates a hypoxic environment that further augments tumor cell growth and metastatic spread. Importantly however, studies during the last decade have shown that the tumor stroma, including the vasculature, can be modulated, or re-educated, to allow better delivery of chemotherapeutic drugs or enhance the efficiency of active immune therapy. Such remodeling of the tumor stroma using genetic, pharmacological and other therapeutic approaches not only enhances selective access into tumors but also reduces toxic side effects. This review focuses on recent novel concepts to modulate tumor stroma and thus locally increase therapeutic efficacy

  1. A Typical Presentation of Orbital Pseudotumor Mimicking Orbital Cellulitis

    Directory of Open Access Journals (Sweden)

    J. Ayatollahi

    2013-10-01

    Full Text Available Introduction: Orbital pseudotumor, also known as idiopathic orbital inflammatory syndrome (IOIS, is a benign, non- infective inflammatory condition of the orbit without identifiable local or systemic causes. The disease may mimics a variety of pathologic conditions. We pre-sent a case of pseudotumor observed in a patient admitted under the name of orbital celluli-ties. Case Report: A 26-year-old woman reffered to our hospital with the history of left ocular pain and headache 2 days before her visit.. Ophthalmological examination of the patient was normal except for the redness and lid edema, mild chemosis and conjunctival injection. Gen-eral assessment was normal but a low grade fever was observed. She was hospitalized as an orbital cellulitis patient. She was treated with intravenous antibiotics. On the third day , sud-denly diplopia, proptosis in her left eye and ocular pain in her right side appeared. MRI re-vealed bilateral enlargement of extraocular muscles. Diagnosis of orbital pseudotumor was made and the patient was treated with oral steroid.She responded promptly to the treatment. Antibiotics were discontinued and steroid was tapered in one month period under close fol-low up. Conclusion: The clinical features of orbital pseudotumor vary widely . Orbital pseudotumor and orbital cellulitis can occasionally demonstrate overlapping features.. Despite complete physical examination and appropriate imaging, sometimes correct diagnosis of the disease would be difficult (Sci J Hamadan Univ Med Sci 2013; 20 (3:256-259

  2. Deadly Sunflower Orbits

    Science.gov (United States)

    Hamilton, Douglas P.

    2018-04-01

    Solar radiation pressure is usually very effective at removing hazardous millimeter-sized debris from distant orbits around asteroidsand other small solar system bodies (Hamilton and Burns 1992). Theprimary loss mechanism, driven by the azimuthal component of radiationpressure, is eccentricity growth followed by a forced collision withthe central body. One large class of orbits, however, neatly sidestepsthis fate. Orbits oriented nearly perpendicular to the solar directioncan maintain their face-on geometry, oscillating slowly around a stableequilibrium orbit. These orbits, designated sunflower orbits, arerelated to terminator orbits studied by spacecraft mission designers(Broschart etal. 2014).Destabilization of sunflower orbits occurs only for particles smallenough that radiation pressure is some tens of percent the strength ofthe central body's direct gravity. This greatly enhanced stability,which follows from the inability of radiation incident normal to theorbit to efficiently drive eccentricities, presents a threat tospacecraft missions, as numerous dangerous projectiles are potentiallyretained in orbit. We have investigated sunflower orbits insupport of the New Horizons, Aida, and Lucy missions and find thatthese orbits are stable for hazardous particle sizes at asteroids,comets, and Kuiper belt objects of differing dimensions. Weinvestigate the sources and sinks for debris that might populate suchorbits, estimate timescales and equilibrium populations, and willreport on our findings.

  3. Tumor biology and cancer therapy – an evolving relationship

    Directory of Open Access Journals (Sweden)

    Lother Ulrike

    2009-08-01

    Full Text Available Abstract The aim of palliative chemotherapy is to increase survival whilst maintaining maximum quality of life for the individual concerned. Although we are still continuing to explore the optimum use of traditional chemotherapy agents, the introduction of targeted therapies has significantly broadened the therapeutic options. Interestingly, the results from current trials put the underlying biological concept often into a new, less favorable perspective. Recent data suggested that altered pathways underlie cancer, and not just altered genes. Thus, an effective therapeutic agent will sometimes have to target downstream parts of a signaling pathway or physiological effects rather than individual genes. In addition, over the past few years increasing evidence has suggested that solid tumors represent a very heterogeneous group of cells with different susceptibility to cancer therapy. Thus, since therapeutic concepts and pathophysiological understanding are continuously evolving a combination of current concepts in tumor therapy and tumor biology is needed. This review aims to present current problems of cancer therapy by highlighting exemplary results from recent clinical trials with colorectal and pancreatic cancer patients and to discuss the current understanding of the underlying reasons.

  4. Surgical management of spinal intramedullary tumors: radical and safe strategy for benign tumors.

    Science.gov (United States)

    Takami, Toshihiro; Naito, Kentaro; Yamagata, Toru; Ohata, Kenji

    2015-01-01

    Surgery for spinal intramedullary tumors remains one of the major challenges for neurosurgeons, due to their relative infrequency, unknown natural history, and surgical difficulty. We are sure that safe and precise resection of spinal intramedullary tumors, particularly encapsulated benign tumors, can result in acceptable or satisfactory postoperative outcomes. General surgical concepts and strategies, technical consideration, and functional outcomes after surgery are discussed with illustrative cases of spinal intramedullary benign tumors such as ependymoma, cavernous malformation, and hemangioblastoma. Selection of a posterior median sulcus, posterolateral sulcus, or direct transpial approach was determined based on the preoperative imaging diagnosis and careful inspection of the spinal cord surface. Tumor-cord interface was meticulously delineated in cases of benign encapsulated tumors. Our retrospective functional analysis of 24 consecutive cases of spinal intramedullary ependymoma followed for at least 6 months postoperatively demonstrated a mean grade on the modified McCormick functional schema of 1.8 before surgery, deteriorating significantly to 2.6 early after surgery ( 6 months after surgery). The risk of functional deterioration after surgery should be taken into serious consideration. Functional deterioration after surgery, including neuropathic pain even long after surgery, significantly affects patient quality of life. Better balance between tumor control and functional preservation can be achieved not only by the surgical technique or expertise, but also by intraoperative neurophysiological monitoring, vascular image guidance, and postoperative supportive care. Quality of life after surgery should inarguably be given top priority.

  5. Incidence of enhancement of the optic nerve/sheath complex in fat-suppression orbit MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ho Kyu; Yoon, Kwon Ha; Choi, Choong Gon; Suh, Dae Chul [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1995-04-15

    To elucidate the incidence of Gd-DTPA enhancement of the optic nerve/sheath complex (ONC) in patients with various ophthalmopathies using fat-suppression MRI. Orbit MRI with fat-suppression technique (ChemSat) was performed in 58 patients with normal and various orbital lesions. The fat-suppression MR was done with and without Gd-DTPA injection in all cases. MR findings were reviewed retrospectively in a blind fashion with respect to presence or absence of contrast enhancement of the ONC. Contrast enhancement of the ONC was seen in 86% (6/7) of cavernous sinus lesions, 80% (8/10) of intraconal lesions excluding the ONC, 57% (16/28) of ONC lesions, 38% (3/8) of ocular lesions, and 2% (1/55) of normal orbits. The ONC enhancement was the most common in optic nerve/sheath tumors (10/10), and pseudotumors (6/6), cavernous sinus dural arteriovenous malformations (3/3) and cavernous sinus thrombosis (2/2), and less frequently seen in optic neuritis (3/14). Enhancement of the ONC may be seen in lesions of the cavernous sinus and orbit other than optic nerve/sheath lesion.

  6. CT findings of malignant nasal cavity tumors

    International Nuclear Information System (INIS)

    Ku, Young Mi; Chun, Kyung Ah; Choi, Kyu Ho; Yu, Won Jong; Kim, Young Joo; Kim, Sung Hoon; Park, Seog Hee; Shinn, Kyung Sub

    1997-01-01

    To evaluate the CT findings of malignant nasal cavity tumors. Retrospective analysis was performed on 20 patients with pathologically-proven malignant nasal cavity tumors. Using CT, we analysed their location, extent of bone destruction and of involvement of adjacent structures, and enhancing pattern. A total of 20 cases included nine squamous cell carcinomas, three olfactory neuroblastomas, three lymphomas, two polymorphic reticulosis, one adenoid cystic carcinoma, one undifferentiated carcinoma and one metastasis from renal cell carcinoma. All cases except one adenoid cystic carcinoma and one squamous cell carcinoma revealed bone destruction or erosion. Aggressive bone destruction and irregular enhancement were seen in eight cases of squamous cell carcinoma, seven cases of which showed involvement of the adjacent paranasal sinuses, nasopharynx, and orbit. Olfactory neuroblastomas were centered in the superior nasal cavity and the adjacent ethmoid sinus, and erosion or destruction of the cribriform plate had occurred. Lymphomas showed bilateral involvement, with uniform contrast enhancement. Polymorphic reticuloses showed perforation or erosion of the nasal septum, with bilateral involvement of the nasal cavity. The location, presence of bone destruction, involvement of adjacent structures, and enhancement pattern of tumor on CT can be helpful for the differential diagnosis of malignant nasal cavity tumors

  7. Concept of APDL, the atomic process description language

    International Nuclear Information System (INIS)

    Sasaki, Akira

    2004-01-01

    The concept of APDL, the Atomic Process Description Language, which provides simple and complete description of atomic model is presented. The syntax to describe electron orbital and configuration is defined for the use in the atomic structure, kinetics and spectral synthesis simulation codes. (author)

  8. Orbits

    CERN Document Server

    Xu, Guochang

    2008-01-01

    This is the first book of the satellite era which describes orbit theory with analytical solutions of the second order with respect to all possible disturbances. Based on such theory, the algorithms of orbits determination are completely revolutionized.

  9. Optimization of fractionated radiotherapy of tumors

    International Nuclear Information System (INIS)

    Ivanov, V.K.

    1984-01-01

    Underlying modern conceptions of clinical radiobiology and mathematic methods in system theory a model of radiation therapy for tumors is developed. To obtain optimal fractionating conditions the principle of gradual optimization is used. A optimal therapeutic method permits to minimize the survival of a tumor cell population with localized lesions of the intact tissue. An analytic research is carried out for the simplest variant of the model. By help of a SORT-program unit the conditions are ascertained for gradual optimization of radiotherapy. (author)

  10. Platelet injectors for Space Shuttle orbit maneuvering engine

    Science.gov (United States)

    Kahl, R. C.; Labotz, R. J.; Bassham, L. B.

    1974-01-01

    The Space Shuttle Orbit Maneuvering Subsystem Rocket Engine employs a platelet element injector concept. This injector has demonstrated 316-sec vacuum specific impulse performance under simulated altitude conditions when tested with a milled slot/electroformed nickel close-out regenerative chamber and a full 71 area ratio nozzle. To date, over 300 altitude engine tests and 300 stability bomb tests have demonstrated stable, erosion free operation with this concept to test durations of 150 seconds. The injector and chamber also meet the reusable requirements of the shuttle with a cycle life capability in excess of 1000 cycles. An extensive altitude restart program has also demonstrated OMS-engine operation over large variations in the burn and coast times with helium saturated propellants.

  11. Ophthalmic plastic and orbital surgery in Taiwan.

    Science.gov (United States)

    Hsu, Chi-Hsin; Lin, I-Chan; Shen, Yun-Dun; Hsu, Wen-Ming

    2014-06-01

    We describe in this paper the current status of ophthalmic plastic and orbital surgery in Taiwan. Data were collected from the Bureau of National Health Insurance of Taiwan, the Bulletin of the Taiwan Ophthalmic Plastic and Reconstructive Society, and the Statistics Yearbook of Practicing Physicians and Health Care Organizations in Taiwan by the Taiwan Medical Association. We ascertained that 94 ophthalmologists were oculoplastic surgeons and accounted for 5.8% of 1621 ophthalmologists in Taiwan. They had their fellowship training abroad (most ophthalmologists trained in the United States of America) or in Taiwan. All ophthalmologists were well trained and capable of performing major oculoplastic surgeries. The payment rates by our National Health Insurance for oculoplastic and orbital surgeries are relatively low, compared to Medicare payments in the United States. Ophthalmologists should promote the concept that oculoplastic surgeons specialize in periorbital plastic and aesthetic surgeries. However, general ophthalmologists should receive more educational courses on oculoplastic and cosmetic surgery. Copyright © 2014. Published by Elsevier B.V.

  12. Earth Observatory Satellite system definition study. Report 1: Orbit/launch vehicle trade-off studies and recommendations

    Science.gov (United States)

    1974-01-01

    A summary of the constraints and requirements on the Earth Observatory Satellite (EOS-A) orbit and launch vehicle analysis is presented. The propulsion system (hydrazine) and the launch vehicle (Delta 2910) selected for EOS-A are examined. The rationale for the selection of the recommended orbital altitude of 418 nautical miles is explained. The original analysis was based on the EOS-A mission with the Thematic Mapper and the High Resolution Pointable Imager. The impact of the revised mission model is analyzed to show how the new mission model affects the previously defined propulsion system, launch vehicle, and orbit. A table is provided to show all aspects of the EOS multiple mission concepts. The subjects considered include the following: (1) mission orbit analysis, (2) spacecraft parametric performance analysis, (3) launch system performance analysis, and (4) orbits/launch vehicle selection.

  13. MOM-E: Moon-Orbiting Mothership Explorer

    Science.gov (United States)

    Murphy, Gloria A.

    2010-01-01

    The National Aeronautics and Space Administration proposed that a new class of robotic space missions and spacecrafts be introduced to "ensure that future missions are safe, sustainable and affordable". Indeed, the United States space program aims for a return to manned space missions beyond Earth orbit, and robotic explorers are intended to pave the way. This vision requires that all future missions become less costly, provide a sustainable business plan, and increase in safety. Over the course of several fast feasibility studies that considered the 3 drivers above, the small-scale, consumer-driven Moon-Orbiting Mothership Explorer (MOM-E) mission was born. MOM-E's goals are to enable space exploration by offering a scaled down platform which carries multiple small space explorers to the Moon. Each payload will be dropped at their desired destination, offering a competitive price to customers. MOM-E's current scope of operations is limited to the Moon and will be used as a proof of concept mission. However, MOM-E is specifically designed with the idea that the platform is scalable.

  14. Real-time tumor tracking using implanted positron emission markers: Concept and simulation study

    International Nuclear Information System (INIS)

    Xu Tong; Wong, Jerry T.; Shikhaliev, Polad M.; Ducote, Justin L.; Al-Ghazi, Muthana S.; Molloi, Sabee

    2006-01-01

    The delivery accuracy of radiation therapy for pulmonary and abdominal tumors suffers from tumor motion due to respiration. Respiratory gating should be applied to avoid the use of a large target volume margin that results in a substantial dose to the surrounding normal tissue. Precise respiratory gating requires the exact spatial position of the tumor to be determined in real time during treatment. Usually, fiducial markers are implanted inside or next to the tumor to provide both accurate patient setup and real-time tumor tracking. However, current tumor tracking systems require either substantial x-ray exposure to the patient or large fiducial markers that limit the value of their application for pulmonary tumors. We propose a real-time tumor tracking system using implanted positron emission markers (PeTrack). Each marker will be labeled with low activity positron emitting isotopes, such as 124 I, 74 As, or 84 Rb. These isotopes have half-lives comparable to the duration of radiation therapy (from a few days to a few weeks). The size of the proposed PeTrack marker will be 0.5-0.8 mm, which is approximately one-half the size of markers currently employed in other techniques. By detecting annihilation gammas using position-sensitive detectors, multiple positron emission markers can be tracked in real time. A multimarker localization algorithm was developed using an Expectation-Maximization clustering technique. A Monte Carlo simulation model was developed for the PeTrack system. Patient dose, detector sensitivity, and scatter fraction were evaluated. Depending on the isotope, the lifetime dose from a 3.7 MBq PeTrack marker was determined to be 0.7-5.0 Gy at 10 mm from the marker. At the center of the field of view (FOV), the sensitivity of the PeTrack system was 240-320 counts/s per 1 MBq marker activity within a 30 cm thick patient. The sensitivity was reduced by 45% when the marker was near the edge of the FOV. The scatter fraction ranged from 12% ( 124 I, 74 As

  15. The Orbital Space Environment and Space Situational Awareness Domain Ontology - Toward an International Information System for Space Data

    Science.gov (United States)

    Rovetto, R.

    2016-09-01

    The orbital space environment is home to natural and artificial satellites, debris, and space weather phenomena. As the population of orbital objects grows so do the potential hazards to astronauts, space infrastructure and spaceflight capability. Orbital debris, in particular, is a universal concern. This and other hazards can be minimized by improving global space situational awareness (SSA). By sharing more data and increasing observational coverage of the space environment we stand to achieve that goal, thereby making spaceflight safer and expanding our knowledge of near-Earth space. To facilitate data-sharing interoperability among distinct orbital debris and space object catalogs, and SSA information systems, I proposed ontology in (Rovetto, 2015) and (Rovetto and Kelso, 2016). I continue this effort toward formal representations and models of the overall domain that may serve to improve peaceful SSA and increase our scientific knowledge. This paper explains the project concept introduced in those publications, summarizing efforts to date as well as the research field of ontology development and engineering. I describe concepts for an ontological framework for the orbital space environment, near-Earth space environment and SSA domain. An ontological framework is conceived as a part of a potential international information system. The purpose of such a system is to consolidate, analyze and reason over various sources and types of orbital and SSA data toward the mutually beneficial goals of safer space navigation and scientific research. Recent internationals findings on the limitations of orbital data, in addition to existing publications on collaborative SSA, demonstrate both the overlap with this project and the need for datasharing and integration.

  16. PRIMARY ENDOPROSTHETIC REPLACEMENT OF THE ANOPHTHALMIC ORBIT IN PATIENTS WITH UVEAL MELANOMA: SIX-YEAR FOLLOW-UP RESULTS

    Directory of Open Access Journals (Sweden)

    A. A. Yarovoy

    2012-01-01

    Full Text Available A locomotor stump was formed in 36 patients (28 women and 8 men, by implanting an endoprosthesis for enucleation of the eyeball with uveal melanoma (UM. The indication for endoprosthesis implantation was no signs of extrabulbar growth. A modified 17–19 mm silicone implant covered with strips from a dura mater graft and medical mesh fabric was used as an orbital implant. The follow-up was 3 to 72 months (mean 32.5 months. All the patients achieved a satisfactory cosmetic effect. None patient was found to have a recurrent orbital tumor. Out of the complications, anterior implant surface denudation was noted in 4 patients. Two patients developed metastases. The absence of recurrent orbital UM at a 6-year follow-up enables primary endoprosthetic replacement of the orbit for UM to be regarded as a safe and reasonable method for patient cosmetic rehabilitation. 

  17. Artist concept of Mercury program study of medical effects and technology

    Science.gov (United States)

    1964-01-01

    Artist concept of Mercury program study of medical effects and technology development. Drawing depicts cut-away view of Mercury capsule orbiting the Earth, showing the astronaut and his capsule's hardware.

  18. Maxillary brown tumor as initial presentation of parathyroid adenoma: A case report

    Directory of Open Access Journals (Sweden)

    Hon-Ke Sia

    2012-07-01

    Full Text Available Brown tumor is a rare late-stage skeletal change caused by long-term stimulation of excess parathyroid hormone. It is not neoplastic, but a reparative cellular process. Common sites of brown tumor are the ribs, clavicle, long bones and pelvic girdle. Solitary maxillary brown tumor as initial presentation of primary hyperparathyroidism is rare; it is often accompanied by brown tumors of the other facial bones. Here, we present the first case of solitary maxillary brown tumor in a 29-year-old ethnic Chinese woman with initial presentation of a large tumor filling the left maxillary sinus. Underlying long-standing primary hyperparathyroidism caused by a large parathyroid adenoma was finally diagnosed. Brown tumor tends to be misdiagnosed as malignancy, and delayed diagnosis of the underlying hyperparathyroidism is common. Our case validates the suggestion that young women have a higher probability of brown tumor. Biopsy of the suspicious bone tumor and blood tests for calcium and parathyroid hormone level are crucial and essential to reach the correct diagnosis. Most brown tumors show spontaneous regression after parathyroidectomy. However, direct excision of the brown tumor may be indicated to avoid the risk of facial deformity and orbital compression at a special anatomical site, as in our case.

  19. Polypropylene Darning: A New Alternative for Reconstruction of Orbital Floor after Total Maxillectomy.

    Science.gov (United States)

    Sharma, Prashant

    2015-06-01

    Removal of orbital floor is an integral part of total (radical) maxillectomy (type IIIa), which if not managed properly, may lead to some eye related distressing complications like diplopia, eyelid malposition, epiphora, dacryocystitis, enopthalmos and ectoprion. Among all, diplopia is the most distressing complication which hampers daily activity. Various options for orbital floor reconstruction are available like titanium sheet, polypropylene mesh, non-vascularized or vascularized bone graft, pedicled flaps, micro-vascular free flaps, prosthesis placement, and split skin graft followed by obturator placement. Till date no-body has tried stabilization of eye ball by 'darning' the orbital floor using non-absorbable suture. 'Polypropylene suture darning' is an easy to learn, novel method with equally good results. Five patients with potentially resectable tumors underwent total maxillectomy. I used polypropylene 3-0 round body suture and 'darning' was done at orbital floor, incorporating periosteum (if remaining) and peri-orbital fat into the sutures. Muscle flaps were done to provide bulk and palatal reconstruction. Assessment of patients was done post-operatively at day-5 i.e., before discharge and at 1 month after surgery, and also in further follow up visits. The results were very good in terms of clear vision & eye movements (directly related to 'darning'), and the aesthetic look of patients and bilateral symmetry were satisfactory (not related to darning). Darning of orbital floor by polypropylene after total maxillectomy is an easy to learn and cost-effective method of reconstruction with good results.

  20. Artist concept of Galileo spacecraft

    Science.gov (United States)

    1988-01-01

    Galileo spacecraft is illustrated in artist concept. Gallileo, named for the Italian astronomer, physicist and mathematician who is credited with construction of the first complete, practical telescope in 1620, will make detailed studies of Jupiter. A cooperative program with the Federal Republic of Germany the Galileo mission will amplify information acquired by two Voyager spacecraft in their brief flybys. Galileo is a two-element system that includes a Jupiter-orbiting observatory and an entry probe. Jet Propulsion Laboratory (JPL) is Galileo project manager and builder of the main spacecraft. Ames Research Center (ARC) has responsibility for the entry probe, which was built by Hughes Aircraft Company and General Electric. Galileo will be deployed from the payload bay (PLB) of Atlantis, Orbiter Vehicle (OV) 104, during mission STS-34.

  1. Swing-arm beam erector (SABER) concept for single astronaut assembly of space structure

    Science.gov (United States)

    Watson, J. J.; Heard, W. L., Jr.; Jensen, J. K.

    1985-01-01

    Results are presented of tests conducted to evaluate a mobile work station/assembly fixture concept that would mechanically assist an astronaut in the on-orbit manual assembly of erectable truss-beams. The concept eliminates astronaut manual translation by use of a motorized work platform with foot restraints. The tests involved assembly of a tetrahedral truss-beam by a test subject in simulated zero gravity (neutral bouyancy in water). A three-bay truss-beam was assembled from 30 aluminum struts with quick-attachment structural joints. The results show that average on-orbit assembly rates of 2.1 struts per minute can be expected for struts of the size employed in these tests.

  2. Local orbitals by minimizing powers of the orbital variance

    DEFF Research Database (Denmark)

    Jansik, Branislav; Høst, Stinne; Kristensen, Kasper

    2011-01-01

    's correlation consistent basis sets, it is seen that for larger penalties, the virtual orbitals become more local than the occupied ones. We also show that the local virtual HF orbitals are significantly more local than the redundant projected atomic orbitals, which often have been used to span the virtual...

  3. Concept Design of High Power Solar Electric Propulsion Vehicles for Human Exploration

    Science.gov (United States)

    Hoffman, David J.; Kerslake, Thomas W.; Hojnicki, Jeffrey S.; Manzella, David H.; Falck, Robert D.; Cikanek, Harry A., III; Klem, Mark D.; Free, James M.

    2011-01-01

    Human exploration beyond low Earth orbit will require enabling capabilities that are efficient, affordable and reliable. Solar electric propulsion (SEP) has been proposed by NASA s Human Exploration Framework Team as one option to achieve human exploration missions beyond Earth orbit because of its favorable mass efficiency compared to traditional chemical propulsion systems. This paper describes the unique challenges associated with developing a large-scale high-power (300-kWe class) SEP vehicle and design concepts that have potential to meet those challenges. An assessment of factors at the subsystem level that must be considered in developing an SEP vehicle for future exploration missions is presented. Overall concepts, design tradeoffs and pathways to achieve development readiness are discussed.

  4. Melanotic neuroectodermal tumor of infancy

    Energy Technology Data Exchange (ETDEWEB)

    Song, Haeng Un; Koh, Kwang Joon [School of Dentistry, Chonbuk National University, Cheonju (Korea, Republic of)

    2002-09-15

    The melanotic neuroectodermal tumor of infancy is a rare neoplasm arising in the first year of life. A 33-day-old female infant had an enlarged alveolar ridge on the right anterior maxilla. Intraoral examination revealed a nonulcerative swelling at the site. An intraoral radiograph showed an ill-defined radiolucency on the right anterior maxilla and displacement of primary incisors from their alveolar sockets. CT scans revealed an expansion of the surrounding bone and partial destruction of the anterior wall of the premaxilla. Histopathologic examination showed the cytoplasm of neuroblastic cells and eosinophilic, epithelioid cells frequently contained a dark brown granular pigment that stained positively to vimentin and HMB45, focally positive to NSE and cytokeratin. Four weeks after the operation, CT scans showed a rapidly growing soft tissue mass occupying right maxillary sinus encroaching to the orbit and nasal cavity. The final diagnosis was made as a malignant melanotic neuroectodermal tumor of infancy.

  5. Orbit Determination with Very Short Arcs: Admissible Regions

    Science.gov (United States)

    Gronchi, G. F.; Milani, A.; de'Michieli Vitturi, M.; Knezevic, Z.

    2004-05-01

    Contemporary observational surveys provide a huge number of detections of small solar system bodies, in particular of asteroids. These have to be reduced in real time in order to optimize the observational strategy and to select the targets for the follow-up and for the subsequent determination of an orbit. Typically, reported astrometry consists of few positions over a short time span, and this information is often not enough to compute a preliminary orbit and perform an identification. Classical methods for preliminary orbit determination based on three observations fail in such cases, and a new approach is necessary to cope with the problem. We introduce the concept of attributable, which is a vector composed by two angles and two angular velocities at a given time. It is then shown that the missing values (geocentric range and range rate), necessary for the computation of an orbit, can be constrained to a compact set that we call admissible region (AR). The latter is defined on the basis of requirements that the body belongs to the solar system, that it is not a satellite of the Earth, and that it is not a "shooting star" (very close and very small). A mathematical description of the AR is given, together with the proof of its topological properties: it turns out that the AR cannot have more than two connected components. A sampling of the AR can be performed by means of a Delaunay triangulation. A finite number of six-parameter sets of initial conditions are thus defined, with each node of triangulation representing a Virtual Asteroid for which it is possible to propagate the corresponding orbit and to predict ephemerides.

  6. Mission operations concepts for Earth Observing System (EOS)

    Science.gov (United States)

    Kelly, Angelita C.; Taylor, Thomas D.; Hawkins, Frederick J.

    1991-01-01

    Mission operation concepts are described which are being used to evaluate and influence space and ground system designs and architectures with the goal of achieving successful, efficient, and cost-effective Earth Observing System (EOS) operations. Emphasis is given to the general characteristics and concepts developed for the EOS Space Measurement System, which uses a new series of polar-orbiting observatories. Data rates are given for various instruments. Some of the operations concepts which require a total system view are also examined, including command operations, data processing, data accountability, data archival, prelaunch testing and readiness, launch, performance monitoring and assessment, contingency operations, flight software maintenance, and security.

  7. Evaluation of Three Cases Using a Novel Titanium Mesh System—Skull-Fit® with Orbital Wall (Skull-Fit WOW®)—For Cranial Base Reconstructions

    Science.gov (United States)

    Hattori, Noriko; Nakajima, Hideo; Tamada, Ikkei; Sakamoto, Yoshiaki; Ohira, Takayuki; Yoshida, Kazunari; Kawase, Takeshi; Kishi, Kazuo

    2011-01-01

    Cranial base reconstructions associated with tumor resections around the orbital wall often require that both the upper and lateral orbital walls be reconstructed during a single procedure. Previously, we used titanium mesh plates that were preoperatively fabricated based on three-dimensional models. Although these plates are precise and do not increase the probability of infection, we still had to use autologous bones to reconstruct the orbital walls. Recently, we developed a new titanium mesh plate—called Skull-Fit®—with orbital wall (Skull-Fit WOW®), enabling us to reconstruct the cranial base and orbital walls without bone grafts. Here, we report on three reconstruction cases in which the novel titanium mesh-orbital wall system was used. In all three cases, the customized titanium mesh system performed satisfactorily with little, if any, complications. PMID:22451827

  8. Composing a Tumor Specific Bacterial Promoter.

    Directory of Open Access Journals (Sweden)

    Igor V Deyneko

    Full Text Available Systemically applied Salmonella enterica spp. have been shown to invade and colonize neoplastic tissues where it retards the growth of many tumors. This offers the possibility to use the bacteria as a vehicle for the tumor specific delivery of therapeutic molecules. Specificity of such delivery is solely depending on promoter sequences that control the production of a target molecule. We have established the functional structure of bacterial promoters that are transcriptionally active exclusively in tumor tissues after systemic application. We observed that the specific transcriptional activation is accomplished by a combination of a weak basal promoter and a strong FNR binding site. This represents a minimal set of control elements required for such activation. In natural promoters, additional DNA remodeling elements are found that alter the level of transcription quantitatively. Inefficiency of the basal promoter ensures the absence of transcription outside tumors. As a proof of concept, we compiled an artificial promoter sequence from individual motifs representing FNR and basal promoter and showed specific activation in a tumor microenvironment. Our results open possibilities for the generation of promoters with an adjusted level of expression of target proteins in particular for applications in bacterial tumor therapy.

  9. Orbital Dynamics of Low-Earth Orbit Laser-Propelled Space Vehicles

    International Nuclear Information System (INIS)

    Yamakawa, Hiroshi; Funaki, Ikkoh; Komurasaki, Kimiya

    2008-01-01

    Trajectories applicable to laser-propelled space vehicles with a laser station in low-Earth orbit are investigated. Laser vehicles are initially located in the vicinity of the Earth-orbiting laser station in low-earth orbit at an altitude of several hundreds kilometers, and are accelerated by laser beaming from the laser station. The laser-propelled vehicles start from low-earth orbit and finally escape from the Earth gravity well, enabling interplanetary trajectories and planetary exploration

  10. Therapeutic Implications from Sensitivity Analysis of Tumor Angiogenesis Models

    Science.gov (United States)

    Poleszczuk, Jan; Hahnfeldt, Philip; Enderling, Heiko

    2015-01-01

    Anti-angiogenic cancer treatments induce tumor starvation and regression by targeting the tumor vasculature that delivers oxygen and nutrients. Mathematical models prove valuable tools to study the proof-of-concept, efficacy and underlying mechanisms of such treatment approaches. The effects of parameter value uncertainties for two models of tumor development under angiogenic signaling and anti-angiogenic treatment are studied. Data fitting is performed to compare predictions of both models and to obtain nominal parameter values for sensitivity analysis. Sensitivity analysis reveals that the success of different cancer treatments depends on tumor size and tumor intrinsic parameters. In particular, we show that tumors with ample vascular support can be successfully targeted with conventional cytotoxic treatments. On the other hand, tumors with curtailed vascular support are not limited by their growth rate and therefore interruption of neovascularization emerges as the most promising treatment target. PMID:25785600

  11. Vibronic coupling density and related concepts

    International Nuclear Information System (INIS)

    Sato, Tohru; Uejima, Motoyuki; Iwahara, Naoya; Haruta, Naoki; Shizu, Katsuyuki; Tanaka, Kazuyoshi

    2013-01-01

    Vibronic coupling density is derived from a general point of view as a one-electron property density. Related concepts as well as their applications are presented. Linear and nonlinear vibronic coupling density and related concepts, orbital vibronic coupling density, reduced vibronic coupling density, atomic vibronic coupling constant, and effective vibronic coupling density, illustrate the origin of vibronic couplings and enable us to design novel functional molecules or to elucidate chemical reactions. Transition dipole moment density is defined as an example of the one-electron property density. Vibronic coupling density and transition dipole moment density open a way to design light-emitting molecules with high efficiency.

  12. MCSCF optimization through combined use of natural orbitals and the Brillouin-Levy-Berthier theorem

    International Nuclear Information System (INIS)

    Ruedenberg, K.; Cheung, L.M.; Elbert, S.T.

    1979-01-01

    A novel approach is developed for optimizing molecular orbitals within the context of a multiconfiguration self-consistent-field problem. The MCSCF wave function is determined through a sequence of eigenvalue problems in the multiconfiguration space and the single-excitation space. They are used iteratively to improve the natural orbitals, which in turn are related, by successively improved transformations, to the MCSCF orbitals. The mathematical problems arising out of this general concept are solved and the computational implementation is discussed. In many applications the method has proven itself as a powerful approach in forcing rapid convergence. Adaptation to spin and spatial symmetry is maintained throughout, and the procedure is applicable to excited states as well as to ground states. 3 figures, 2 tables

  13. How does the Mass Transport in Disk Galaxy Models Influence the Character of Orbits?

    Directory of Open Access Journals (Sweden)

    Zotos Euaggelos E.

    2014-12-01

    Full Text Available We explore the regular or chaotic nature of orbits of stars moving in the meridional (R, z plane of an axially symmetric time-dependent disk galaxy model with a central, spherically symmetric nucleus. In particular, mass is linearly transported from the disk to the galactic nucleus, in order to mimic, in a way, the case of self-consistent interactions of an actual N-body simulation. We thus try to unveil the influence of this mass transportation on the different families of orbits of stars by monitoring how the percentage of chaotic orbits, as well as the percentages of orbits of the main regular resonant families, evolve as the galaxy develops a dense and massive nucleus in its core. The SALI method is applied to samples of orbits in order to distinguish safely between ordered and chaotic motion. In addition, a method based on the concept of spectral dynamics is used for identifying the various families of regular orbits and also for recognizing the secondary resonances that bifurcate from them. Our computations strongly suggest that the amount of the observed chaos is substantially increased as the nucleus becomes more massive. Furthermore, extensive numerical calculations indicate that there are orbits which change their nature from regular to chaotic and vice versa and also orbits which maintain their orbital character during the galactic evolution. The present outcomes are compared to earlier related work.

  14. NIAC Phase II Orbiting Rainbows: Future Space Imaging with Granular Systems

    Science.gov (United States)

    Quadrelli, Marco B.; Basinger, Scott; Arumugam, Darmindra; Swartzlander, Grover

    2017-01-01

    Inspired by the light scattering and focusing properties of distributed optical assemblies in Nature, such as rainbows and aerosols, and by recent laboratory successes in optical trapping and manipulation, we propose a unique combination of space optics and autonomous robotic system technology, to enable a new vision of space system architecture with applications to ultra-lightweight space optics and, ultimately, in-situ space system fabrication. Typically, the cost of an optical system is driven by the size and mass of the primary aperture. The ideal system is a cloud of spatially disordered dust-like objects that can be optically manipulated: it is highly reconfigurable, fault-tolerant, and allows very large aperture sizes at low cost. This new concept is based on recent understandings in the physics of optical manipulation of small particles in the laboratory and the engineering of distributed ensembles of spacecraft swarms to shape an orbiting cloud of micron-sized objects. In the same way that optical tweezers have revolutionized micro- and nano-manipulation of objects, our breakthrough concept will enable new large scale NASA mission applications and develop new technology in the areas of Astrophysical Imaging Systems and Remote Sensing because the cloud can operate as an adaptive optical imaging sensor. While achieving the feasibility of constructing one single aperture out of the cloud is the main topic of this work, it is clear that multiple orbiting aerosol lenses could also combine their power to synthesize a much larger aperture in space to enable challenging goals such as exo-planet detection. Furthermore, this effort could establish feasibility of key issues related to material properties, remote manipulation, and autonomy characteristics of cloud in orbit. There are several types of endeavors (science missions) that could be enabled by this type of approach, i.e. it can enable new astrophysical imaging systems, exo-planet search, large apertures

  15. Duct-ectatic type of mucin producing tumor of the pancreas--new concept of pancreatic neoplasia.

    Science.gov (United States)

    Kimura, W; Sasahira, N; Yoshikawa, T; Muto, T; Makuuchi, M

    1996-01-01

    Although there have been recent reports of mucin-producing tumor of the pancreas, there has been no thorough clinicopathological analysis of a large number of cases. Two hundred forty four cases of mucin-producing tumor of the pancreas from Japanese, European and American reports, together with 15 cases of our own, were analyzed clinicopathologically. Mucin-producing tumor of the pancreas was found in 177 males and 82 females (M:F = 2.2:1). The mean age was 65.5 years. Jaundice, diabetes mellitus and a past history of pancreatitis were found in 15%-19% of the cases. The tumor was most frequently (62%) found in the head of the pancreas. Pathologically, hyperplasia or adenoma was found in 58 cases, and adenocarcinoma in 160 cases. Five-year-survival rate by the Kaplan-Meier method was 82.6% in all of the cases and postoperative survival curve was much better in cases with this type of carcinoma than in cases with ordinary pancreatic duct cell carcinoma (5-year-survival rate: 82.6% vs 17.3%). Serum tumor markers such as CEA or CA 19-9 were not effective in differentiating between benign and malignant, or in determining the degree of cancerous spread, while cytology of the pancreatic juice and biopsy of the tumor could contribute to the diagnosis. Mucin-producing tumor has unique clinicopathological characteristics, such as the dilated main pancreatic duct or branches, dilatation of the orifice of the papilla of Vater, or good prognosis. Since a diagnosis for benign or malignant is very difficult in some cases, methods for distinguishing benign from malignant lesions or for determining cancerous spread, such as molecular biological techniques, should be established.

  16. Giant deep orbital dermoid cyst presenting early in infancy in a Nigerian child: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Fasina Oluyemi

    2012-09-01

    Full Text Available Abstract Introduction Dermoid cysts are the most common orbital cystic lesions seen in children. While superficial orbital dermoid cysts present early in life, deep dermoid cysts remain clinically occult until adolescence or adulthood. We here present a case of a deep orbital dermoid cyst in a Nigerian child that became symptomatic early in infancy. Case presentation A female Nigerian infant of Yoruba ethnicity presented at three months of age with left non-axial proptosis and a hazy cornea. A superotemporal cystic orbital mass was seen on ultrasonography, and her parents were counseled for simple tumor excision. They however defaulted, only for their child to re-present two years later with gradually progressive proptosis, an enlarged orbit and keratinized ocular surface, necessitating orbital exenteration. Conclusion Deep orbital dermoid cysts may be symptomatic from birth. Late presentation may result in an irreversible loss of vision, as demonstrated in our case. The need for public enlightenment on early presentation and prompt management of such benign lesions is emphasized.

  17. Mid-Ventilation Concept for Mobile Pulmonary Tumors: Internal Tumor Trajectory Versus Selective Reconstruction of Four-Dimensional Computed Tomography Frames Based on External Breathing Motion

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Wilbert, Juergen; Krieger, Thomas; Richter, Anne; Baier, Kurt; Flentje, Michael

    2009-01-01

    Purpose: To evaluate the accuracy of direct reconstruction of mid-ventilation and peak-phase four-dimensional (4D) computed tomography (CT) frames based on the external breathing signal. Methods and Materials: For 11 patients with 15 pulmonary targets, a respiration-correlated CT study (4D CT) was acquired for treatment planning. After retrospective time-based sorting of raw projection data and reconstruction of eight CT frames equally distributed over the breathing cycle, mean tumor position (P mean ), mid-ventilation frame, and breathing motion were evaluated based on the internal tumor trajectory. Analysis of the external breathing signal (pressure sensor around abdomen) with amplitude-based sorting of projections was performed for direct reconstruction of the mid-ventilation frame and frames at peak phases of the breathing cycle. Results: On the basis of the eight 4D CT frames equally spaced in time, tumor motion was largest in the craniocaudal direction, with 12 ± 7 mm on average. Tumor motion between the two frames reconstructed at peak phases was not different in the craniocaudal and anterior-posterior directions but was systematically smaller in the left-right direction by 1 mm on average. The 3-dimensional distance between P mean and the tumor position in the mid-ventilation frame based on the internal tumor trajectory was 1.2 ± 1 mm. Reconstruction of the mid-ventilation frame at the mean amplitude position of the external breathing signal resulted in tumor positions 2.0 ± 1.1 mm distant from P mean . Breathing-induced motion artifacts in mid-ventilation frames caused negligible changes in tumor volume and shape. Conclusions: Direct reconstruction of the mid-ventilation frame and frames at peak phases based on the external breathing signal was reliable. This makes the reconstruction of only three 4D CT frames sufficient for application of the mid-ventilation technique in clinical practice.

  18. Radiovolumetry of the orbit

    International Nuclear Information System (INIS)

    Abujamra, S.

    1983-01-01

    The authors present a method called ''Radiovolumetry of the orbit'' that permits the evaluation of the orbital volume from anteroposterior skull X-Rays (CALDWELL 30 0 position). The research was based in the determination of the orbital volume with lead spheres, in 1010 orbits of 505 dry skulls of Anatomy Museums. After the dry skulls was X-rayed six frontal orbital diameters were made, with care to correct the radiographic amplification. PEARSON correlation coeficient test was applied between the mean orbital diameter and the orbital volume. The result was r = 0,8 with P [pt

  19. Linking tumor glycolysis and immune evasion in cancer: Emerging concepts and therapeutic opportunities.

    Science.gov (United States)

    Ganapathy-Kanniappan, Shanmugasundaram

    2017-08-01

    Metabolic reprogramming and immune evasion are two hallmarks of cancer. Metabolic reprogramming is exemplified by cancer's propensity to utilize glucose at an exponential rate which in turn is linked with "aerobic glycolysis", popularly known as the "Warburg effect". Tumor glycolysis is pivotal for the efficient management of cellular bioenergetics and uninterrupted cancer growth. Mounting evidence suggests that tumor glycolysis also plays a key role in instigating immunosuppressive networks that are critical for cancer cells to escape immune surveillance ("immune evasion"). Recent data show that induction of cellular stress or metabolic dysregulation sensitize cancer cells to antitumor immune cells implying that metabolic reprogramming and immune evasion harmonize during cancer progression. However, the molecular link between these two hallmarks of cancer remains obscure. In this review the molecular intricacies of tumor glycolysis that facilitate immune evasion has been discussed in the light of recent research to explore immunotherapeutic potential of targeting cancer metabolism. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Microenvironmental independence associated with tumor progression.

    Science.gov (United States)

    Anderson, Alexander R A; Hassanein, Mohamed; Branch, Kevin M; Lu, Jenny; Lobdell, Nichole A; Maier, Julie; Basanta, David; Weidow, Brandy; Narasanna, Archana; Arteaga, Carlos L; Reynolds, Albert B; Quaranta, Vito; Estrada, Lourdes; Weaver, Alissa M

    2009-11-15

    Tumor-microenvironment interactions are increasingly recognized to influence tumor progression. To understand the competitive dynamics of tumor cells in diverse microenvironments, we experimentally parameterized a hybrid discrete-continuum mathematical model with phenotypic trait data from a set of related mammary cell lines with normal, transformed, or tumorigenic properties. Surprisingly, in a resource-rich microenvironment, with few limitations on proliferation or migration, transformed (but not tumorigenic) cells were most successful and outcompeted other cell types in heterogeneous tumor simulations. Conversely, constrained microenvironments with limitations on space and/or growth factors gave a selective advantage to phenotypes derived from tumorigenic cell lines. Analysis of the relative performance of each phenotype in constrained versus unconstrained microenvironments revealed that, although all cell types grew more slowly in resource-constrained microenvironments, the most aggressive cells were least affected by microenvironmental constraints. A game theory model testing the relationship between microenvironment resource availability and competitive cellular dynamics supports the concept that microenvironmental independence is an advantageous cellular trait in resource-limited microenvironments.

  1. DRAGONS - A Micrometeoroid and Orbital Debris Impact Sensor

    Science.gov (United States)

    Liou, J. -C.; Corsaro, R.; Giovane, F.; Anderson, C.; Sadilek, A.; Burchell, M.; Hamilton, J.

    2015-01-01

    The Debris Resistive/Acoustic Grid Orbital Navy-NASA Sensor (DRAGONS) is intended to be a large area impact sensor for in situ measurements of micrometeoroids and orbital debris (MMOD) in the millimeter or smaller size regime. These MMOD particles are too small to be detected by ground-based radars and optical telescopes, but are still large enough to be a serious safety concern for human space activities and robotic missions in the low Earth orbit (LEO) region. The nominal detection area of a DRAGONS unit is 1 m2, consisting of several independently operated panels. The approach of the DRAGONS design is to combine different particle impact detection principles to maximize information that can be extracted from detected events. After more than 10 years of concept and technology development, a 1 m2 DRAGONS system has been selected for deployment on the International Space Station (ISS) in August 2016. The project team achieved a major milestone when the Preliminary Design Review (PDR) was completed in May 2015. Once deployed on the ISS, this multi-year mission will provide a unique opportunity to demonstrate the MMOD detection capability of the DRAGONS technologies and to collect data to better define the small MMOD environment at the ISS altitude.

  2. Molecular orbitals of nucleons in nucleus-nucleus collisions

    International Nuclear Information System (INIS)

    Imanishi, B.; Oertzen, W. von.

    1986-05-01

    A formalism for the dynamical treatment of the molecular orbitals of valence nucleons in nucleus-nucleus collisions at low bombarding energy is developed with the use of the coupled-reaction-channel (CRC) method. The Coriolis coupling effects as well as the finite mass effects of the nucleon are taken into account in this model, of rotating molecular orbitals, RMO. First, the validity of the concept is examined from the view point of the multi-step processes in a standard CRC calculation for systems containing two identical [core] nuclei. The calculations show strong CRC effects particularly in the case where the mixing of different l-parity orbitals - called hybridization in atomic physics - occurs. Then, the RMO representation for active nucleons is applied to the same systems and compared to the CRC results. Its validity is investigated with respect to the radial motion (adiabaticity) and the rotation of the molecular axis (radial and rotational coupling). Characteristic molecular orbitals of covalent molecules appear as rotationally stable states (K = 1/2) with good adiabaticity. Using the RMO's we obtain a new interpretation of various scattering phenomena. Dynamically induced changes in the effective Q-values (or scaling of energies), dynamically induced moments of inertia and an dynamically induced effective (L · S) interaction are obtained as a result of the molecular orbital formation. Various experimental data on transfer and subbarrier fusion reactions are understood in terms of the RMO's and their adiabatic potentials. Landau-Zener transitions, which strongly depend on the total angular momentum of the system, definitely predict the observation of characteristic changes in the cross sections for the inelastic scattering 13 C( 12 C, 12 C) 13 C* (3.086 MeV, 1/2 + ) with the change of the bombarding energy. (author)

  3. WE-EF-BRA-11: Precision Partial-Tumor Irradiation of Dorsal Rodent Mammary Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Malcolm, J [Duke Medical Physics Graduate Program, Durham, NC (United States); Boss, K [Department of Comparative Biomedical Sciences, North Carolina State University (United States); Dewhirst, M [Dpt of Radiation and Cancer Biology, Duke University, Durham, North Carolina (United States); Oldham, M [Dpt of Radiation Oncology, Duke University Medical Center, Durham, NC (United States)

    2015-06-15

    Purpose: To introduce a pre-clinical treatment technique on a micro-irradiator to treat specific volumes of dorsal mammary tumors in BALB/c mice while sparing lungs and spine. This technique facilitates pre-clinical investigation of tumor response to sub-optimal radiation treatments in which a portion of the tumor is unirradiated, known as a “marginal miss”. In-vitro data suggests that partial tumor radiations trigger a more aggressive phenotype in non-irradiated, regional tumor cells via bystander effects. As the lung tissue is spared, the impact of marginal miss on the development of pulmonary metastasis may be assessed. Methods: End to end test was performed on three BALB/c mice as proof of concept for larger studies. 1Gy was delivered on the micro-irradiator employing previously unexplored lateral parallel-opposed diamond and/or triangle-shaped beams. The margins of the treatment beam were defined using a combination of tumor palpation, barium fiducial markers, and real-time fluoroscopic images. The dose distribution was independently verified with kilovoltage beam Monte Carlo dose calculations with 7% statistical uncertainty and double exposure images. As a final step, the technique was used in a larger pre-clinical study (15Gy, 36 BALB/c mice) and lung metastasis in response to tumor irradiation of 100%, 50% and 0% was quantified. Results: For the Monte-Carlo dose calculations, the dose volume histograms established a maximum dose within the un-irradiated and radiated portions of the mammary tumor of 0.3Gy and 1.5Gy respectively, with a sharp gradient at the boundary. 100% of the lung volume received less than 0.5Gy. This technique proved suitable for a pre-clinical marginal miss study with 50% more lung metastases in partially-radiated mouse models compared to completely. Conclusion: We have developed a novel treatment technique for partial or full irradiation of dorsal mammary tumors incorporating lung sparing.The technique will be useful for exploring

  4. Radiation-induced tumors of the nervous system

    International Nuclear Information System (INIS)

    Bernstein, M.; Laperriere, N.

    1991-01-01

    Therapeutic and nontherapeutic ionizing radiation has long been recognized as a putative carcinogenic agent, but the evidence that radiation causes tumors is circumstantial at worst and statistically significant at best. There are no distinct histological, biochemical, cytogenetic, or clinical criteria that can be used to determine if an individual tumor was caused directly by previous irradiation of the anatomic area. Additional supportive evidence for radiation-induced tumors includes a position correlation between radiation dose and tumor incidence (usually in the low dose range) and experimental induction of the same neoplasm in appropriate animal models. even if these criteria are fulfilled, coincidental development of a second tumor can never be discounted in an individual patient, particularly if there is an underlying diathesis to develop multiple tumors of different histology, such as in Recklinghausen's disease, or if there is an strong family history for the development of neoplastic disease. In this paper, the authors critically evaluate the available evidence to support the hypothesis that radiation induces tumors in the nervous system. The current concepts of radiation carcinogenesis are discussed and are followed by a discussion of animal data and clinical experience in humans. Finally, a brief discussion on treatment of radiation-induced nervous system tumors is presented

  5. NASA's Gravitational - Wave Mission Concept Study

    Science.gov (United States)

    Stebbins, Robin; Jennrich, Oliver; McNamara, Paul

    2012-01-01

    With the conclusion of the NASA/ESA partnership on the Laser Interferometer Space Antenna (LISA) Project, NASA initiated a study to explore mission concepts that will accomplish some or all of the LISA science objectives at lower cost. The Gravitational-Wave Mission Concept Study consisted of a public Request for Information (RFI), a Core Team of NASA engineers and scientists, a Community Science Team, a Science Task Force, and an open workshop. The RFI yielded were 12 mission concepts, 3 instrument concepts and 2 technologies. The responses ranged from concepts that eliminated the drag-free test mass of LISA to concepts that replace the test mass with an atom interferometer. The Core Team reviewed the noise budgets and sensitivity curves, the payload and spacecraft designs and requirements, orbits and trajectories and technical readiness and risk. The Science Task Force assessed the science performance by calculating the horizons. the detection rates and the accuracy of astrophysical parameter estimation for massive black hole mergers, stellar-mass compact objects inspiraling into central engines. and close compact binary systems. Three mission concepts have been studied by Team-X, JPL's concurrent design facility. to define a conceptual design evaluate kt,y performance parameters. assess risk and estimate cost and schedule. The Study results are summarized.

  6. Large spin relaxation anisotropy and valley-Zeeman spin-orbit coupling in WSe2/graphene/h -BN heterostructures

    Science.gov (United States)

    Zihlmann, Simon; Cummings, Aron W.; Garcia, Jose H.; Kedves, Máté; Watanabe, Kenji; Taniguchi, Takashi; Schönenberger, Christian; Makk, Péter

    2018-02-01

    Large spin-orbital proximity effects have been predicted in graphene interfaced with a transition-metal dichalcogenide layer. Whereas clear evidence for an enhanced spin-orbit coupling has been found at large carrier densities, the type of spin-orbit coupling and its relaxation mechanism remained unknown. We show an increased spin-orbit coupling close to the charge neutrality point in graphene, where topological states are expected to appear. Single-layer graphene encapsulated between the transition-metal dichalcogenide WSe2 and h -BN is found to exhibit exceptional quality with mobilities as high as 1 ×105 cm2 V-1 s-1. At the same time clear weak antilocalization indicates strong spin-orbit coupling, and a large spin relaxation anisotropy due to the presence of a dominating symmetric spin-orbit coupling is found. Doping-dependent measurements show that the spin relaxation of the in-plane spins is largely dominated by a valley-Zeeman spin-orbit coupling and that the intrinsic spin-orbit coupling plays a minor role in spin relaxation. The strong spin-valley coupling opens new possibilities in exploring spin and valley degree of freedom in graphene with the realization of new concepts in spin manipulation.

  7. Technology Development and Demonstration Concepts for the Space Elevator

    Science.gov (United States)

    Smitherman, David V., Jr.

    2004-01-01

    During the 1990s several discoveries and advances in the development of carbon nano-tube (CNT) materials indicated that material strengths many times greater than common high-strength composite materials might be possible. Progress in the development of this material led to renewed interest in the space elevator concept for construction of a tether structure from the surface of the Earth through a geostationary orbit (GEO) and thus creating a new approach to Earth-to-orbit transportation infrastructures. To investigate this possibility the author, in 1999, managed for NASA a space elevator work:hop at the Marshall Space Flight Center to explore the potential feasibility of space elevators in the 21 century, and to identify the critical technologies and demonstration missions needed to make development of space elevators feasible. Since that time, a NASA Institute for Advanced Concepts (NIAC) funded study of the Space Elevator proposed a concept for a simpler first space elevator system using more near-term technologies. This paper will review some of the latest ideas for space elevator development, the critical technologies required, and some of the ideas proposed for demonstrating the feasibility for full-scale development of an Earth to GEO space elevator. Critical technologies include CNT composite materials, wireless power transmission, orbital object avoidance, and large-scale tether deployment and control systems. Numerous paths for technology demonstrations have been proposed utilizing ground experiments, air structures. LEO missions, the space shuttle, the international Space Station, GEO demonstration missions, demonstrations at the lunar L1 or L2 points, and other locations. In conclusion, this paper finds that the most critical technologies for an Earth to GEO space elevator include CNT composite materials development and object avoidance technologies; that lack of successful development of these technologies need not preclude continued development of

  8. Orbital wall fractures

    International Nuclear Information System (INIS)

    Iinuma, Toshitaka; Ishio, Ken-ichirou; Yoshinami, Hiroyoshi; Kuriyama, Jun-ichi; Hirota, Yoshiharu.

    1993-01-01

    A total of 59 cases of mild facial fractures (simple orbital wall fractures, 34 cases, other facial fractures, 25 cases) with the clinical suspects of orbital wall fractures were evaluated both by conventional views (Waters' and Caldwell views) and coronal CT scans. Conventional views were obtained, as an average, after 4 days and CT after 7 days of injuries. Both the medial wall and the floor were evaluated at two sites, i.e., anterior and posterior. The ethmoid-maxillary plate was also included in the study. The degree of fractures was classified as, no fractures, fractures of discontinuity, dislocation and fragmentation. The coronal CT images in bone window condition was used as reference and the findings were compared between conventional views and CT. The correct diagnosis was obtained as follows: orbital floor (anterior, 78%, posterior, 73%), medial orbital wall (anterior, 72%, posterior, 72%) and ethmoid-maxillary plate (64%). The false positive diagnosis was as follows: orbital floor (anterior only, 13%), medial orbital wall (anterior only, 7%) and ethmoid-maxillary plate (11%). The false negative diagnosis was as follows: orbital floor (anterior, 9%, posterior, 10%), medial orbital wall (anterior, 21%, posterior, 28%) and ethmoid-maxillary plate (21%). The results were compared with those of others in the past. (author)

  9. Risk of spacecraft on-orbit obsolescence: Novel framework, stochastic modeling, and implications

    Science.gov (United States)

    Dubos, Gregory F.; Saleh, Joseph H.

    2010-07-01

    The Government Accountability Office (GAO) has repeatedly noted the difficulties encountered by the Department of Defense (DOD) in keeping its acquisition of space systems on schedule and within budget. Among the recommendations provided by GAO, a minimum Technology Readiness Level (TRL) for technologies to be included in the development of a space system is advised. The DOD considers this recommendation impractical arguing that if space systems were designed with only mature technologies (high TRL), they would likely become obsolete on-orbit fairly quickly. The risk of on-orbit obsolescence is a key argument in the DOD's position for dipping into low technology maturity for space acquisition programs, but this policy unfortunately often results in the cost growth and schedule slippage criticized by the GAO. The concept of risk of on-orbit obsolescence has remained qualitative to date. In this paper, we formulate a theory of risk of on-orbit obsolescence by building on the traditional notion of obsolescence and adapting it to the specificities of space systems. We develop a stochastic model for quantifying and analyzing the risk of on-orbit obsolescence, and we assess, in its light, the appropriateness of DOD's rationale for maintaining low TRL technologies in its acquisition of space assets as a strategy for mitigating on-orbit obsolescence. Our model and results contribute one step towards the resolution of the conceptual stalemate on this matter between the DOD and the GAO, and we hope will inspire academics to further investigate the risk of on-orbit obsolescence.

  10. Future earth orbit transportation systems/technology implications

    Science.gov (United States)

    Henry, B. Z.; Decker, J. P.

    1976-01-01

    Assuming Space Shuttle technology to be state-of-the-art, projected technological advances to improve the capabilities of single-stage-to-orbit (SSTO) derivatives are examined. An increase of about 30% in payload performance can be expected from upgrading the present Shuttle system through weight and drag reductions and improvements in the propellants and engines. The ODINEX (Optimal Design Integration Executive Computer Program) program has been used to explore design options. An advanced technology SSTO baseline system derived from ODINEX analysis has a conventional wing-body configuration using LOX/LH engines, three with two-position nozzles with expansion ratios of 40 and 200 and four with fixed nozzles with an expansion ratio of 40. Two assisted-takeoff approaches are under consideration in addition to a concept in which the orbital vehicle takes off empty using airbreathing propulsion and carries out a rendezvous with two large cryogenic tankers carrying propellant at an altitude of 6100 m. Further approaches under examination for propulsion, aerothermodynamic design, and design integration are described.

  11. Computed tomography of tumors of paranasal sinuses and face

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sun Wha [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1982-09-15

    The computed tomography can image both bone and soft tissue structures of paranasal sinuses and face and so CT has added an important new dimension to radiological evaluation of disease of paranasal sinuses and face. CT is more accurate method of staging of tumors and essential for therapeutic planning. The author studied 25 cases of proven tumors of paranasal sinuses and face during the period from October 1977 to August 1980 in Kyung Hee University Hospital. The results were as follows: 1. Among 14 females and 11 male, their age range was from 14 years to 65 year. 2. The distribution of tumors were mucocele, squamous cell carcinoma, metastatic carcinoma, meningioma, angiofibroma, Masson's hemangiosarcoma, fibrous dysplasia, neurogenic sarcoma, Schwannoma, hemangioma, epidermoid, transitional cell carcinoma and unknown. 3. Determination of location and extent of mucocele was easily done by CT. Thus in all cases of ethmoid mucocele, chief complaint of exophthalmos could be easily explained by identification of its extension into peripheral fat space of orbit. 4. It is our belief that CT was useful method to determine staging of tumors of paranasal sinuses and was essential in choosing appropriate treatment modality. 5. The contrast enhancement is generally not helpful in pathologic diagnosis of tumors but intracranial extension of tumors are clearly defined by contrast enhancement.

  12. Different tumor microenvironments contain functionally distinct subsets of macrophages derived from Ly6C(high) monocytes

    NARCIS (Netherlands)

    Movahedi, Kiavash; Laoui, Damya; Gysemans, Conny; Baeten, Martijn; Stangé, Geert; van den Bossche, Jan; Mack, Matthias; Pipeleers, Daniel; In't Veld, Peter; de Baetselier, Patrick; van Ginderachter, Jo A.

    2010-01-01

    Tumor-associated macrophages (TAM) form a major component of the tumor stroma. However, important concepts such as TAM heterogeneity and the nature of the monocytic TAM precursors remain speculative. Here, we show for the first time that mouse mammary tumors contained functionally distinct subsets

  13. MR imaging of the brain: tumors

    International Nuclear Information System (INIS)

    Sartor, K.

    1999-01-01

    The radiologic modality that most likely provides the imaging information needed in a patient suspected of having a brain tumor is MR imaging. A brain tumor can be reliably ruled out if the MR examination is performed properly and experts interpret the results as negative. If there is a tumor, however, its exact location and topography must be determined. Important for therapy and prognosis are also tumor properties such as histologic type and grade, as well as effects on adjacent brain structures. Although potentially a noninvasive method of in vivo neuropathology, MR is still far from being sufficiently specific, as dissimilar lesions may look the same despite the use of refined imaging protocols. The evolution of MR imaging continues, however, making further methodologic improvement likely. Presently, advanced methods, such as diffusion- and perfusion-weighted MR imaging, functional MR imaging, neuronavigation based on MR imaging data, and the use of MR imaging during surgery (intraoperative MR imaging), influence the way patients are treated. Likewise, follow-up imaging (monitoring) of tumor patients by MR has become more effective, and experience has shown how to distinguish reactive changes from recurrent tumor. In the future, MR imaging may gain importance in the development of novel therapeutic concepts. (orig.)

  14. Charge-spin-orbital dynamics of one-dimensional two-orbital Hubbard model

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Hiroaki [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, Ibaraki 319-1195 (Japan)

    2010-01-15

    We study the real-time evolution of a charge-excited state in a one-dimensional e{sub g}-orbital degenerate Hubbard model, by a time-dependent density-matrix renormalization group method. Considering a chain along the z direction, electrons hop between adjacent 3z{sup 2}-r{sup 2} orbitals, while x{sup 2}-y{sup 2} orbitals are localized. For the charge-excited state, a holon-doublon pair is introduced into the ground state at quarter filling. At initial time, there is no electron in a holon site, while a pair of electrons occupies 3z{sup 2}-r{sup 2} orbital in a doublon site. As the time evolves, the holon motion is governed by the nearest-neighbor hopping, but the electron pair can transfer between 3z{sup 2}-r{sup 2} orbital and x{sup 2}-y{sup 2} orbital through the pair hopping in addition to the nearest-neighbor hopping. Thus holon and doublon propagate at different speed due to the pair hopping that is characteristic of multi-orbital systems.

  15. Impact of ITRS 2014 realizations on altimeter satellite precise orbit determination

    Science.gov (United States)

    Zelensky, Nikita P.; Lemoine, Frank G.; Beckley, Brian D.; Chinn, Douglas S.; Pavlis, Despina E.

    2018-01-01

    This paper evaluates orbit accuracy and systematic error for altimeter satellite precise orbit determination on TOPEX, Jason-1, Jason-2 and Jason-3 by comparing the use of four SLR/DORIS station complements from the International Terrestrial Reference System (ITRS) 2014 realizations with those based on ITRF2008. The new Terrestrial Reference Frame 2014 (TRF2014) station complements include ITRS realizations from the Institut National de l'Information Géographique et Forestière (IGN) ITRF2014, the Jet Propulsion Laboratory (JPL) JTRF2014, the Deutsche Geodätisches Forschungsinstitut (DGFI) DTRF2014, and the DORIS extension to ITRF2014 for Precise Orbit Determination, DPOD2014. The largest source of error stems from ITRF2008 station position extrapolation past the 2009 solution end time. The TRF2014 SLR/DORIS complement impact on the ITRF2008 orbit is only 1-2 mm RMS radial difference between 1992-2009, and increases after 2009, up to 5 mm RMS radial difference in 2016. Residual analysis shows that station position extrapolation error past the solution span becomes evident even after two years, and will contribute to about 3-4 mm radial orbit error after seven years. Crossover data show the DTRF2014 orbits are the most accurate for the TOPEX and Jason-2 test periods, and the JTRF2014 orbits for the Jason-1 period. However for the 2016 Jason-3 test period only the DPOD2014-based orbits show a strong and statistically significant margin of improvement. The positive results with DTRF2014 suggest the new approach to correct station positions or normal equations for non-tidal loading before combination is beneficial. We did not find any compelling POD advantage in using non-linear over linear station velocity models in our SLR & DORIS orbit tests on the Jason satellites. The JTRF2014 proof-of-concept ITRS realization demonstrates the need for improved SLR+DORIS orbit centering when compared to the Ries (2013) CM annual model. Orbit centering error is seen as an annual

  16. Detecting brain tumor in pathological slides using hyperspectral imaging.

    Science.gov (United States)

    Ortega, Samuel; Fabelo, Himar; Camacho, Rafael; de la Luz Plaza, María; Callicó, Gustavo M; Sarmiento, Roberto

    2018-02-01

    Hyperspectral imaging (HSI) is an emerging technology for medical diagnosis. This research work presents a proof-of-concept on the use of HSI data to automatically detect human brain tumor tissue in pathological slides. The samples, consisting of hyperspectral cubes collected from 400 nm to 1000 nm, were acquired from ten different patients diagnosed with high-grade glioma. Based on the diagnosis provided by pathologists, a spectral library of normal and tumor tissues was created and processed using three different supervised classification algorithms. Results prove that HSI is a suitable technique to automatically detect high-grade tumors from pathological slides.

  17. Orbit transfer rocket engine technology program: Automated preflight methods concept definition

    Science.gov (United States)

    Erickson, C. M.; Hertzberg, D. W.

    1991-01-01

    The possibility of automating preflight engine checkouts on orbit transfer engines is discussed. The minimum requirements in terms of information and processing necessary to assess the engine'e integrity and readiness to perform its mission were first defined. A variety of ways for remotely obtaining that information were generated. The sophistication of these approaches varied from a simple preliminary power up, where the engine is fired up for the first time, to the most advanced approach where the sensor and operational history data system alone indicates engine integrity. The critical issues and benefits of these methods were identified, outlined, and prioritized. The technology readiness of each of these automated preflight methods were then rated on a NASA Office of Exploration scale used for comparing technology options for future mission choices. Finally, estimates were made of the remaining cost to advance the technology for each method to a level where the system validation models have been demonstrated in a simulated environment.

  18. Some New Locally Optimal Control Laws for Sailcraft Dynamics in Heliocentric Orbits

    Directory of Open Access Journals (Sweden)

    F. A. Abd El-Salam

    2013-01-01

    Full Text Available The concept of solar sailing and its developing spacecraft is presented. The gravitational and solar radiation forces are considered. The effect of source of radiation pressure and the force due to coronal mass ejections and solar wind on the sailcraft configurations is modeled. Some analytical control laws with some mentioned input constraints for optimizing sailcraft dynamics in heliocentric orbit using lagrange’s planetary equations are obtained. Optimum force vector in a required direction is maximized by deriving optimal sail cone angle. Ignoring the absorbed and diffusely reflected parts of the radiation, some special cases are obtained. New control laws that maximize thrust to obtain certain required maximization in some particular orbital element are obtained.

  19. Particle orbit tracking on a parallel computer: Hypertrack

    International Nuclear Information System (INIS)

    Cole, B.; Bourianoff, G.; Pilat, F.; Talman, R.

    1991-05-01

    A program has been written which performs particle orbit tracking on the Intel iPSC/860 distributed memory parallel computer. The tracking is performed using a thin element approach. A brief description of the structure and performance of the code is presented, along with applications of the code to the analysis of accelerator lattices for the SSC. The concept of ''ensemble tracking'', i.e. the tracking of ensemble averages of noninteracting particles, such as the emittance, is presented. Preliminary results of such studies will be presented. 2 refs., 6 figs

  20. Imaging Tumor Necrosis with Ferumoxytol.

    Directory of Open Access Journals (Sweden)

    Maryam Aghighi

    Full Text Available Ultra-small superparamagnetic iron oxide nanoparticles (USPIO are promising contrast agents for magnetic resonance imaging (MRI. USPIO mediated proton relaxation rate enhancement is strongly dependent on compartmentalization of the agent and can vary depending on their intracellular or extracellular location in the tumor microenvironment. We compared the T1- and T2-enhancement pattern of intracellular and extracellular USPIO in mouse models of cancer and pilot data from patients. A better understanding of these MR signal effects will enable non-invasive characterizations of the composition of the tumor microenvironment.Six 4T1 and six MMTV-PyMT mammary tumors were grown in mice and imaged with ferumoxytol-enhanced MRI. R1 relaxation rates were calculated for different tumor types and different tumor areas and compared with histology. The transendothelial leakage rate of ferumoxytol was obtained by our measured relaxivity of ferumoxytol and compared between different tumor types, using a t-test. Additionally, 3 patients with malignant sarcomas were imaged with ferumoxytol-enhanced MRI. T1- and T2-enhancement patterns were compared with histopathology in a descriptive manner as a proof of concept for clinical translation of our observations.4T1 tumors showed central areas of high signal on T1 and low signal on T2 weighted MR images, which corresponded to extracellular nanoparticles in a necrotic core on histopathology. MMTV-PyMT tumors showed little change on T1 but decreased signal on T2 weighted images, which correlated to compartmentalized nanoparticles in tumor associated macrophages. Only 4T1 tumors demonstrated significantly increased R1 relaxation rates of the tumor core compared to the tumor periphery (p<0.001. Transendothelial USPIO leakage was significantly higher for 4T1 tumors (3.4±0.9x10-3 mL/min/100cm3 compared to MMTV-PyMT tumors (1.0±0.9x10-3 mL/min/100 cm3. Likewise, ferumoxytol imaging in patients showed similar findings with

  1. Traumatic orbital CSF leak

    Science.gov (United States)

    Borumandi, Farzad

    2013-01-01

    Compared to the cerebrospinalfluid (CSF) leak through the nose and ear, the orbital CSF leak is a rare and underreported condition following head trauma. We present the case of a 49-year-old woman with oedematous eyelid swelling and ecchymosis after a seemingly trivial fall onto the right orbit. Apart from the above, she was clinically unremarkable. The CT scan revealed a minimally displaced fracture of the orbital roof with no emphysema or intracranial bleeding. The fractured orbital roof in combination with the oedematous eyelid swelling raised the suspicion for orbital CSF leak. The MRI of the neurocranium demonstrated a small-sized CSF fistula extending from the anterior cranial fossa to the right orbit. The patient was treated conservatively and the lid swelling resolved completely after 5 days. Although rare, orbital CSF leak needs to be included in the differential diagnosis of periorbital swelling following orbital trauma. PMID:24323381

  2. Deep Space Habitat ECLSS Design Concept

    Science.gov (United States)

    Curley, Su; Stambaugh, Imelda; Swickrath, Michael; Anderson, Molly S.; Rotter, Henry

    2012-01-01

    Life support is vital to human spaceflight, and most current life support systems employ single-use hardware or regenerable technologies that throw away the waste products, relying on resupply to make up the consumables lost in the process. Because the long-term goal of the National Aeronautics and Space Administration is to expand human presence beyond low-earth orbit, life support systems must become self-sustaining for missions where resupply is not practical. From May through October 2011, the life support team at the Johnson Space Center was challenged to define requirements, develop a system concept, and create a preliminary life support system design for a non-planetary Deep Space Habitat that could sustain a crew of four in near earth orbit for a duration of 388 days. Some of the preferred technology choices to support this architecture were passed over because the mission definition has an unmanned portion lasting 825 days. The main portion of the architecture was derived from technologies currently integrated on the International Space Station as well as upcoming technologies with moderate Technology Readiness Levels. The final architecture concept contains only partially-closed air and water systems, as the breakeven point for some of the closure technologies was not achieved with the mission duration.

  3. Deep Space Habitat ECLS Design Concept

    Science.gov (United States)

    Curley, Su; Stambaugh, Imelda; Swickrath, Mike; Anderson, Molly; Rotter, Hank

    2011-01-01

    Life support is vital to human spaceflight, and most current life support systems employ single-use hardware or regenerable technologies that throw away the waste products, relying on resupply to make up the consumables lost in the process. Because the long-term goal of the National Aeronautics and Space Administration is to expand human presence beyond low-earth orbit, life support systems must become self-sustaining for missions where resupply is not practical. From May through October 2011, the life support team at the Johnson Space Center was challenged to define requirements, develop a system concept, and create a preliminary life support system design for a non-planetary Deep Space Habitat that could sustain a crew of four in near earth orbit for a duration of 388 days. Some of the preferred technology choices to support this architecture were passed over as the mission definition also has an unmanned portion lasting 825 days. The main portion of the architecture was derived from technologies currently integrated on the International Space Station as well as upcoming technologies with moderate Technology Readiness Levels. The final architecture concept contains only partially-closed air and water systems, as the breakeven point for some of the closure technologies was not achieved with the mission duration.

  4. Skin metastasis from conventional giant cell tumor of bone: conceptual significance

    International Nuclear Information System (INIS)

    Tyler, W.; Barrett, T.; Frassica, F.; McCarthy, E.

    2002-01-01

    A conventional giant cell tumor of the proximal femur recurred twice locally and developed pulmonary nodules. The lung lesions were felt to be an example of ''benign'' metastases. Eight months after the initial presentation, the patient developed a single skin nodule on the contralateral leg. Histologic features of the skin nodule showed conventional giant cell tumor identical to the bone lesion. This nodule is a manifestation of arterial metastasis typical of any malignant tumor and seemingly contradicts the concept of ''benign '' metastasis. (orig.)

  5. Pre-Flight Tests with Astronauts, Flight and Ground Hardware, to Assure On-Orbit Success

    Science.gov (United States)

    Haddad Michael E.

    2010-01-01

    On-Orbit Constraints Test (OOCT's) refers to mating flight hardware together on the ground before they will be mated on-orbit or on the Lunar surface. The concept seems simple but it can be difficult to perform operations like this on the ground when the flight hardware is being designed to be mated on-orbit in a zero-g/vacuum environment of space or low-g/vacuum environment on the Lunar/Mars Surface. Also some of the items are manufactured years apart so how are mating tasks performed on these components if one piece is on-orbit/on Lunar/Mars surface before its mating piece is planned to be built. Both the Internal Vehicular Activity (IVA) and Extra-Vehicular Activity (EVA) OOCT's performed at Kennedy Space Center will be presented in this paper. Details include how OOCT's should mimic on-orbit/Lunar/Mars surface operational scenarios, a series of photographs will be shown that were taken during OOCT's performed on International Space Station (ISS) flight elements, lessons learned as a result of the OOCT's will be presented and the paper will conclude with possible applications to Moon and Mars Surface operations planned for the Constellation Program.

  6. Quantum-orbit theory of high-order atomic processes in strong fields

    International Nuclear Information System (INIS)

    Milosevic, D.B.

    2005-01-01

    Full text: Atoms submitted to strong laser fields can emit electrons and photons of very high energies. These processes find a highly intuitive and also quantitative explanation in terms of Feynman's path integral and the concept of quantum orbits. The quantum-orbit formalism is particularly useful for high-order atomic processes in strong laser fields. For such multi-step processes there is an intermediate step during which the electron is approximately under the influence of the laser field only and can absorb energy from the field. This leads to the appearance of the plateau structures in the emitted electron or photon spectra. Usual examples of such processes are high-order harmonic generation (HHG) and high-order above threshold ionization (HATI). These structures were also observed in high-order above-threshold detachment, laser-assisted x-ray-atom scattering, laser-assisted electron-ion recombination, and electron-atom scattering. We will present high-order strong-field approximation (SFA) and show how the quantum-orbit formalism follows from it. This will be done for various above-mentioned processes. For HHG a classification of quantum orbits will be given [10) and generalized to the presence of a static field. The low-energy part of the HHG spectra and the enhancement of HHG near the channel closings can be explained taking into account a large number of quantum orbits. For HATI we will concentrate on the case of few-cycle laser pulse. The influence of the carrier-envelope relative phase on the HATI spectrum can easily be explained in terms of quantum orbits. The SFA and the quantum-orbit results will be compared with the results obtained by Dieter Bauer using ab initio solutions of the time-dependent Schroedinger equation. It will be shown that the Coulomb effects are important for low-energy electron spectra. Refs. 11 (author)

  7. Limitations of Electromagnetic Ion Cyclotron Wave Observations in Low Earth Orbit

    Directory of Open Access Journals (Sweden)

    Junga Hwang

    2018-03-01

    Full Text Available Pc1 pulsations are geomagnetic fluctuations in the frequency range of 0.2 to 5 Hz. There have been several observations of Pc1 pulsations in low earth orbit by MAGSAT, DE-2, Viking, Freja, CHAMP, and SWARM satellites. However, there has been a clear limitation in resolving the spatial and temporal variations of the pulsation by using a single-point observation by a single satellite. To overcome such limitations of previous observations, a new space mission was recently initiated, using the concept of multi-satellites, named the Small scale magNetospheric and Ionospheric Plasma Experiments (SNIPE. The SNIPE mission consists of four nanosatellites (~10 kg, which will be launched into a polar orbit at an altitude of 600 km (TBD in 2020. Four satellites will be deployed in orbit, and the distances between each satellite will be controlled from 10 to 1,000 km by a high-end formation-flying algorithm. One of the possible science targets of the SNIPE mission is observing electromagnetic ion cyclotron (EMIC waves. In this paper, we report on examples of observations, showing the limitations of previous EMIC observations in low earth orbit, and suggest possibilities to overcome those limitations through a new mission.

  8. Electrical polarization and orbital magnetization: the modern theories

    International Nuclear Information System (INIS)

    Resta, Raffaele

    2010-01-01

    Macroscopic polarization P and magnetization M are the most fundamental concepts in any phenomenological description of condensed media. They are intensive vector quantities that intuitively carry the meaning of dipole per unit volume. But for many years both P and the orbital term in M evaded even a precise microscopic definition, and severely challenged quantum-mechanical calculations. If one reasons in terms of a finite sample, the electric (magnetic) dipole is affected in an extensive way by charges (currents) at the sample boundary, due to the presence of the unbounded position operator in the dipole definitions. Therefore P and the orbital term in M-phenomenologically known as bulk properties-apparently behave as surface properties; only spin magnetization is problemless. The field has undergone a genuine revolution since the early 1990s. Contrary to a widespread incorrect belief, P has nothing to do with the periodic charge distribution of the polarized crystal: the former is essentially a property of the phase of the electronic wavefunction, while the latter is a property of its modulus. Analogously, the orbital term in M has nothing to do with the periodic current distribution in the magnetized crystal. The modern theory of polarization, based on a Berry phase, started in the early 1990s and is now implemented in most first-principle electronic structure codes. The analogous theory for orbital magnetization started in 2005 and is partly work in progress. In the electrical case, calculations have concerned various phenomena (ferroelectricity, piezoelectricity, and lattice dynamics) in several materials, and are in spectacular agreement with experiments; they have provided thorough understanding of the behaviour of ferroelectric and piezoelectric materials. In the magnetic case the very first calculations are appearing at the time of writing (2010). Here I review both theories on a uniform ground in a density functional theory (DFT) framework, pointing out

  9. An Artificial Gravity Spacecraft Approach which Minimizes Mass, Fuel and Orbital Assembly Reg

    Science.gov (United States)

    Bell, L.

    2002-01-01

    The Sasakawa International Center for Space Architecture (SICSA) is undertaking a multi-year research and design study that is exploring near and long-term commercial space development opportunities. Space tourism in low-Earth orbit (LEO), and possibly beyond LEO, comprises one business element of this plan. Supported by a financial gift from the owner of a national U.S. hotel chain, SICSA has examined opportunities, requirements and facility concepts to accommodate up to 100 private citizens and crewmembers in LEO, as well as on lunar/planetary rendezvous voyages. SICSA's artificial gravity Science Excursion Vehicle ("AGSEV") design which is featured in this presentation was conceived as an option for consideration to enable round-trip travel to Moon and Mars orbits and back from LEO. During the course of its development, the AGSEV would also serve other important purposes. An early assembly stage would provide an orbital science and technology testbed for artificial gravity demonstration experiments. An ultimate mature stage application would carry crews of up to 12 people on Mars rendezvous missions, consuming approximately the same propellant mass required for lunar excursions. Since artificial gravity spacecraft that rotate to create centripetal accelerations must have long spin radii to limit adverse effects of Coriolis forces upon inhabitants, SICSA's AGSEV design embodies a unique tethered body concept which is highly efficient in terms of structural mass and on-orbit assembly requirements. The design also incorporates "inflatable" as well as "hard" habitat modules to optimize internal volume/mass relationships. Other important considerations and features include: maximizing safety through element and system redundancy; means to avoid destabilizing mass imbalances throughout all construction and operational stages; optimizing ease of on-orbit servicing between missions; and maximizing comfort and performance through careful attention to human needs. A

  10. Orbitals from local RDMFT: Are they Kohn-Sham or natural orbitals?

    International Nuclear Information System (INIS)

    Theophilou, Iris; Helbig, Nicole; Lathiotakis, Nektarios N.; Gidopoulos, Nikitas I.; Rubio, Angel

    2015-01-01

    Recently, an approximate theoretical framework was introduced, called local reduced density matrix functional theory (local-RDMFT), where functionals of the one-body reduced density matrix (1-RDM) are minimized under the additional condition that the optimal orbitals satisfy a single electron Schrödinger equation with a local potential. In the present work, we focus on the character of these optimal orbitals. In particular, we compare orbitals obtained by local-RDMFT with those obtained with the full minimization (without the extra condition) by contrasting them against the exact NOs and orbitals from a density functional calculation using the local density approximation (LDA). We find that the orbitals from local-RMDFT are very close to LDA orbitals, contrary to those of the full minimization that resemble the exact NOs. Since local RDMFT preserves the good quality of the description of strong static correlation, this finding opens the way to a mixed density/density matrix scheme, where Kohn-Sham orbitals obtain fractional occupations from a minimization of the occupation numbers using 1-RDM functionals. This will allow for a description of strong correlation at a cost only minimally higher than a density functional calculation

  11. Wigner functions for the pair angle and orbital angular momentum. Possible applications in quantum information theories

    International Nuclear Information System (INIS)

    Kastrup, H.A.

    2017-01-01

    The framework of Wigner functions for the canonical pair angle and orbital angular momentum, derived and analyzed in 2 recent papers [H. A. Kastrup, Phys. Rev. A 94, 062113(2016) and Phys. Rev. A 95, 052111(2017)], is applied to elementary concepts of quantum information like qubits and 2-qubits, e.g., entangled EPR/Bell states etc. Properties of the associated Wigner functions are discussed and illustrated. The results may be useful for quantum information experiments with orbital angular momenta of light beams or electron beams.

  12. Wigner functions for the pair angle and orbital angular momentum. Possible applications in quantum information theories

    Energy Technology Data Exchange (ETDEWEB)

    Kastrup, H.A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Theory Group

    2017-10-17

    The framework of Wigner functions for the canonical pair angle and orbital angular momentum, derived and analyzed in 2 recent papers [H. A. Kastrup, Phys. Rev. A 94, 062113(2016) and Phys. Rev. A 95, 052111(2017)], is applied to elementary concepts of quantum information like qubits and 2-qubits, e.g., entangled EPR/Bell states etc. Properties of the associated Wigner functions are discussed and illustrated. The results may be useful for quantum information experiments with orbital angular momenta of light beams or electron beams.

  13. Natural killer/T-cell lymphoma invading the orbit and globe.

    Science.gov (United States)

    Lyons, Lance J; Vrcek, Ivan; Somogyi, Marie; Taheri, Kevin; Admirand, Joan H; Chexal, Saradha; Loukas, Demetrius F; Nakra, Tanuj

    2017-10-01

    Natural killer/T-cell lymphomas are extremely rare and carry high mortality rates. Epidemiologically, these cancers tend to affect mainly Asian and South American patients and are associated with Epstein-Barr virus seropositivity. This report details a 78-year-old Vietnamese woman who presented initially with vitritis of unknown cause, but later developed proptosis and conjunctival involvement as her disease spread. Biopsies of the orbit, ethmoid sinus, and conjunctiva were found to be significant for natural killer/T-cell lymphoma. The case highlights the diagnostic difficulty of this tumor given its rarity and ability to mimic other disorders.

  14. System concepts and design examples for optical communication with planetary spacecraft

    Science.gov (United States)

    Lesh, James R.

    Systems concepts for optical communication with future deep-space (planetary) spacecraft are described. These include not only the optical transceiver package aboard the distant spacecraft, but the earth-vicinity optical-communications receiving station as well. Both ground-based, and earth-orbiting receivers are considered. Design examples for a number of proposed or potential deep-space missions are then presented. These include an orbital mission to Saturn, a Lander and Rover mission to Mars, and an astronomical mission to a distance of 1000 astronomical units.

  15. Deep Space Habitat Concept Demonstrator

    Science.gov (United States)

    Bookout, Paul S.; Smitherman, David

    2015-01-01

    This project will develop, integrate, test, and evaluate Habitation Systems that will be utilized as technology testbeds and will advance NASA's understanding of alternative deep space mission architectures, requirements, and operations concepts. Rapid prototyping and existing hardware will be utilized to develop full-scale habitat demonstrators. FY 2014 focused on the development of a large volume Space Launch System (SLS) class habitat (Skylab Gen 2) based on the SLS hydrogen tank components. Similar to the original Skylab, a tank section of the SLS rocket can be outfitted with a deep space habitat configuration and launched as a payload on an SLS rocket. This concept can be used to support extended stay at the Lunar Distant Retrograde Orbit to support the Asteroid Retrieval Mission and provide a habitat suitable for human missions to Mars.

  16. Development of a metal-clad advanced composite shear web design concept

    Science.gov (United States)

    Laakso, J. H.

    1974-01-01

    An advanced composite web concept was developed for potential application to the Space Shuttle Orbiter main engine thrust structure. The program consisted of design synthesis, analysis, detail design, element testing, and large scale component testing. A concept was sought that offered significant weight saving by the use of Boron/Epoxy (B/E) reinforced titanium plate structure. The desired concept was one that was practical and that utilized metal to efficiently improve structural reliability. The resulting development of a unique titanium-clad B/E shear web design concept is described. Three large scale components were fabricated and tested to demonstrate the performance of the concept: a titanium-clad plus or minus 45 deg B/E web laminate stiffened with vertical B/E reinforced aluminum stiffeners.

  17. eTumorType, An Algorithm of Discriminating Cancer Types for Circulating Tumor Cells or Cell-free DNAs in Blood

    Directory of Open Access Journals (Sweden)

    Jinfeng Zou

    2017-04-01

    Full Text Available With the technology development on detecting circulating tumor cells (CTCs and cell-free DNAs (cfDNAs in blood, serum, and plasma, non-invasive diagnosis of cancer becomes promising. A few studies reported good correlations between signals from tumor tissues and CTCs or cfDNAs, making it possible to detect cancers using CTCs and cfDNAs. However, the detection cannot tell which cancer types the person has. To meet these challenges, we developed an algorithm, eTumorType, to identify cancer types based on copy number variations (CNVs of the cancer founding clone. eTumorType integrates cancer hallmark concepts and a few computational techniques such as stochastic gradient boosting, voting, centroid, and leading patterns. eTumorType has been trained and validated on a large dataset including 18 common cancer types and 5327 tumor samples. eTumorType produced high accuracies (0.86–0.96 and high recall rates (0.79–0.92 for predicting colon, brain, prostate, and kidney cancers. In addition, relatively high accuracies (0.78–0.92 and recall rates (0.58–0.95 have also been achieved for predicting ovarian, breast luminal, lung, endometrial, stomach, head and neck, leukemia, and skin cancers. These results suggest that eTumorType could be used for non-invasive diagnosis to determine cancer types based on CNVs of CTCs and cfDNAs.

  18. Threshold for extinction and survival in stochastic tumor immune system

    Science.gov (United States)

    Li, Dongxi; Cheng, Fangjuan

    2017-10-01

    This paper mainly investigates the stochastic character of tumor growth and extinction in the presence of immune response of a host organism. Firstly, the mathematical model describing the interaction and competition between the tumor cells and immune system is established based on the Michaelis-Menten enzyme kinetics. Then, the threshold conditions for extinction, weak persistence and stochastic persistence of tumor cells are derived by the rigorous theoretical proofs. Finally, stochastic simulation are taken to substantiate and illustrate the conclusion we have derived. The modeling results will be beneficial to understand to concept of immunoediting, and develop the cancer immunotherapy. Besides, our simple theoretical model can help to obtain new insight into the complexity of tumor growth.

  19. Antisymmetric Orbit Functions

    Directory of Open Access Journals (Sweden)

    Anatoliy Klimyk

    2007-02-01

    Full Text Available In the paper, properties of antisymmetric orbit functions are reviewed and further developed. Antisymmetric orbit functions on the Euclidean space $E_n$ are antisymmetrized exponential functions. Antisymmetrization is fulfilled by a Weyl group, corresponding to a Coxeter-Dynkin diagram. Properties of such functions are described. These functions are closely related to irreducible characters of a compact semisimple Lie group $G$ of rank $n$. Up to a sign, values of antisymmetric orbit functions are repeated on copies of the fundamental domain $F$ of the affine Weyl group (determined by the initial Weyl group in the entire Euclidean space $E_n$. Antisymmetric orbit functions are solutions of the corresponding Laplace equation in $E_n$, vanishing on the boundary of the fundamental domain $F$. Antisymmetric orbit functions determine a so-called antisymmetrized Fourier transform which is closely related to expansions of central functions in characters of irreducible representations of the group $G$. They also determine a transform on a finite set of points of $F$ (the discrete antisymmetric orbit function transform. Symmetric and antisymmetric multivariate exponential, sine and cosine discrete transforms are given.

  20. Angles-only relative orbit determination in low earth orbit

    Science.gov (United States)

    Ardaens, Jean-Sébastien; Gaias, Gabriella

    2018-06-01

    The paper provides an overview of the angles-only relative orbit determination activities conducted to support the Autonomous Vision Approach Navigation and Target Identification (AVANTI) experiment. This in-orbit endeavor was carried out by the German Space Operations Center (DLR/GSOC) in autumn 2016 to demonstrate the capability to perform spaceborne autonomous close-proximity operations using solely line-of-sight measurements. The images collected onboard have been reprocessed by an independent on-ground facility for precise relative orbit determination, which served as ultimate instance to monitor the formation safety and to characterize the onboard navigation and control performances. During two months, several rendezvous have been executed, generating a valuable collection of images taken at distances ranging from 50 km to only 50 m. Despite challenging experimental conditions characterized by a poor visibility and strong orbit perturbations, angles-only relative positioning products could be continuously derived throughout the whole experiment timeline, promising accuracy at the meter level during the close approaches. The results presented in the paper are complemented with former angles-only experience gained with the PRISMA satellites to better highlight the specificities induced by different orbits and satellite designs.

  1. Orbital fractures: a review

    Directory of Open Access Journals (Sweden)

    Jeffrey M Joseph

    2011-01-01

    Full Text Available Jeffrey M Joseph, Ioannis P GlavasDivision of Ophthalmic Plastic and Reconstructive Surgery, Department of Ophthalmology, School of Medicine, New York University, New York, NY, USA; Manhattan Eye, Ear, and Throat Hospital, New York, NY, USAAbstract: This review of orbital fractures has three goals: 1 to understand the clinically relevant orbital anatomy with regard to periorbital trauma and orbital fractures, 2 to explain how to assess and examine a patient after periorbital trauma, and 3 to understand the medical and surgical management of orbital fractures. The article aims to summarize the evaluation and management of commonly encountered orbital fractures from the ophthalmologic perspective and to provide an overview for all practicing ophthalmologists and ophthalmologists in training.Keywords: orbit, trauma, fracture, orbital floor, medial wall, zygomatic, zygomatic complex, zmc fracture, zygomaticomaxillary complex fractures 

  2. SAMSI: An orbiting spatial interferometer for micro-arc second astronomical observations. [Spacecraft Array for Michelson Spatial Interferometry (SAMSI)

    Science.gov (United States)

    Stachnik, R. V.; Gezari, D. Y.

    1985-01-01

    The concept and performance of (SAMSI) Spacecraft Array for Michelson Spatial Interferometry, an orbiting spatial interferometer comprised of three free-flying spacecraft, two collector telescopes and a central mixing station are described. In the one-dimensional interferometry mode orbits exist which provide natural scanning of the baseline. These orbits place extremely small demands on thrusters and fuel consumption. Resolution of 0.00001 arcsecond and magnitude limits of mv = 15 to 20 are achievable in a single orbit. In the imaging mode, SAMSI could synthesize images equivalent to those produced by equal diameter filled apertures in space, making use of the fuel resupply capability of a space station. Simulations indicate that image reconstruction can be performed with milliarcsecond resolution to a visual magnitude 12 in 12 hr of spiral scanning integration time.

  3. Radiotherapy in the management of orbital lymphoma

    International Nuclear Information System (INIS)

    Bolek, Timothy W.; Moyses, H. Michael; Marcus, Robert B.; Mendenhall, Nancy Price

    1996-01-01

    Purpose/Objective: This retrospective study reviews the treatment technique, disease outcome and complications of radiotherapy used in the management of lymphoma involving the orbits. Materials and Methods: Thirty-eight patients were treated between May 1969 and January 1995 with a median follow-up of 8.3 years. All patients had biopsy-proven orbital lymphoma. Therapy was delivered with curative intent in 20 patients and with palliative intent in 18 patients who had known systemic disease. Of the 20 patients treated with curative intent, 14 had low-grade and 6 had intermediate or high-grade disease. None received chemotherapy. Most patients received treatment with 250 kVP or 60 Co X rays, using either an en face anterior field or wedged anterior and lateral fields. Treatment dose ranged from 5 to 53 Gy with a median of 25 Gy. Lens shielding was performed using either a lead contact lens or a hanging brass shield. For patients treated for cure, cause-specific survival and freedom from distant relapse were calculated using the Kaplan-Meier method. Results: Control of disease in the orbit was achieved in all but 1 patient, who developed an out-of-field recurrence after irradiation of a lacrimal tumor. This patient was salvaged with further radiotherapy. In the patients treated curatively, 5 year actuarial freedom from distant relapse was 61% for those with low-grade and 33% for those with intermediate/high-grade disease (p = 0.08). Cause-specific survival at 5 years was 89% for patients with low-grade and 33% for those with intermediate/high grade disease (p = 0.005). There were 2 contralateral orbital failures, both in patients with low-grade disease, and both patients were salvaged with further irradiation. Treatment failed in nodal sites alone in 4 patients, and none were salvaged. Relapses occurred in both nodal and extra nodal sites in 3 patients, and 2 of them were treated successfully with chemotherapy. Acute toxicity was minimal. Cataracts developed in 7 of 21

  4. The Orbital Debris Problem and the Challenges for Environment Remediation

    Science.gov (United States)

    Liou, J.-C.

    2014-01-01

    LEO debris population will continue to increase even with a good implementation of the commonly-adopted mitigation measures. The root-cause of the increase is catastrophic collisions involving large/massive intact objects (rocket bodies or spacecraft). The major mission-ending risks for most operational spacecraft, however, come from impacts with debris just above the threshold of the protection shields (5-mm to 1-cm). A solution-driven approach is to seek: Concepts for removal of massive intacts with high P(collision); Concepts capable of preventing collisions involving intacts; Concepts for removal of 5-mm to 1-cm debris; Enhanced impact protection shields for valuable space assets. Key questions for remediation consideration of orbital debris: What is the acceptable threat level? What are the mission objectives? What is the appropriate roadmap/timeframe for remediation? Support advanced technology development when an economically viable approach is identified. Address non-technical issues, such as policy, coordination, ownership, legal, and liability at the national and international levels.

  5. Peripheral orbit model

    CERN Document Server

    Hara, Yasuo

    1975-01-01

    Peripheral orbit model, in which an incoming hadron is assumed to revolve in a peripheral orbit around a target hadron, is discussed. The non-diffractive parts of two-body reaction amplitudes of hadrons are expressed in terms of the radius, width an absorptivity of the orbit. The radius of the orbit is about 1 fm and the width of the orbit is determined by the range of the interaction between the hadrons. The model reproduces all available experimental data on differential cross-sections and polarizations of $K^{-}p\\to K^{-}p$ and $\\bar K^{\\circ}n$ reactions for all angles successfully. This contribution is not included in the proceedings since it will appear in Progress of Theoretical Physics Vol. 51 (1974) No 2. Any person interested in the subject may apply for reprints to the author.

  6. GNSS Transpolar Earth Reflectometry exploriNg System (G-TERN): Mission Concept

    DEFF Research Database (Denmark)

    Cardellach, Estel; Wickert, Jens; Baggen, Rens

    2018-01-01

    . Over polar areas, the G-TERN will measure sea ice surface elevation (polarimetry aspects at 30-km resolution and 3-days full coverage. G-TERN will implement the interferometric GNSS reflectometry concept, from a single satellite in near-polar orbit with capability...

  7. HLA-mismatched hematopoietic stem cell tranplantation for pediatric solid tumors

    Directory of Open Access Journals (Sweden)

    Andrea Pession

    2011-06-01

    Full Text Available Even if the overall survival of children with cancer is significantly improved over these decades, the cure rate of high-risk pediatric solid tumors such as neuroblastoma, Ewing’s sarcoma family tumors or rhabdomiosarcoma remain challenging. Autologous hematopoietic stem cell transplantation (HSCT allows chemotherapy dose intensification beyond marrow tolerance and has become a fundamental tool in the multimodal therapeutical approach of these patients. Anyway this procedure does not allow to these children an eventfree survival approaching more than 50% at 5 years. New concepts of allogeneic HSCT and in particular HLA-mismatched HSCT for high risk solid tumors do not rely on escalation of chemo therapy intensity and tumor load reduction but rather on a graft-versus-tumor effect. We here report an experimental study design of HLA-mismatched HSCT for the treatment of pediatric solid tumors and the inherent preliminary results.

  8. Orbital transport

    International Nuclear Information System (INIS)

    Oertel, H. Jr.; Koerner, H.

    1993-01-01

    The Third Aerospace Symposium in Braunschweig presented, for the first time, the possibility of bringing together the classical disciplines of aerospace engineering and the natural science disciplines of meteorology and air chemistry in a european setting. In this way, aspects of environmental impact on the atmosphere could be examined quantitatively. An essential finding of the european conference, is the unrestricted agreement of the experts that the given launch frequencies of the present orbital transport result in a negligible amount of pollutants being released in the atmosphere. The symposium does, however, call attention to the increasing need to consider the effect of orbital and atmospheric environmental impact of a future increase in launch frequencies of orbital transport in connection with future space stations. The Third Aerospace Symposium, 'Orbital Transport, Technical, Meteorological and Chemical Aspects', constituted a first forum of discussion for engineers and scientists. Questions of new orbital transport technologies and their environmental impact were to be discussed towards a first consensus. Through the 34 reports and articles, the general problems of space transportation and environmental protection were addressed, as well as particular aspects of high temperatures during reentry in the atmosphere of the earth, precision navigation of flight vehicles or flow behavior and air chemistry in the stratosphere. (orig./CT). 342 figs

  9. Orbital apex syndrome associated with fractures of the inferomedial orbital wall

    Directory of Open Access Journals (Sweden)

    Sugamata A

    2013-03-01

    Full Text Available Akira SugamataDepartment of Plastic and Reconstructive Surgery, Tokyo Medical University Hachioji Medical Center, Tokyo, JapanAbstract: Although trauma is one of the main causes of orbital apex syndrome (OAS, reports of OAS associated with orbital fractures are relatively rare. We recently treated two patients who sustained severe visual impairment with damage to multiple cranial nerves (third to sixth associated with inferomedial orbital wall fractures. In these patients, posterior movement of the globe caused neuropathy of the cranial and optic nerves by posterior globe edema and hemorrhage, or direct impact between the globe and wall, which might then have induced OAS in the cases described in this report. Steroid therapy was unsuccessful for optic neuropathy due to the delay between injury and administration. When treating patients with inferomedial orbital blowout fractures due to globe-to-wall contact, it is necessary to routinely assess and monitor visual acuity since there may be a delay between the injury and OAS onset.Keywords: orbital apex syndrome, orbital fracture, blowout fracture, optic nerve, globe-to-wall contact mechanism

  10. Using FDG-PET activity as a surrogate for tumor cell density and its effect on equivalent uniform dose calculation

    International Nuclear Information System (INIS)

    Zhou Sumin; Wong, Terence Z.; Marks, Lawrence B.

    2004-01-01

    The concept of equivalent uniform dose (EUD) has been suggested as a means to quantitatively consider heterogeneous dose distributions within targets. Tumor cell density/function is typically assumed to be uniform. We herein propose to use 18 F-labeled 2-deoxyglucose (FDG) positron emission tomography (PET) tumor imaging activity as a surrogate marker for tumor cell density to allow the EUD concept to include intratumor heterogeneities and to study its effect on EUD calculation. Thirty-one patients with lung cancer who had computerized tomography (CT)-based 3D planning and PET imaging were studied. Treatment beams were designed based on the information from both the CT and PET scans. Doses were calculated in 3D based on CT images to reflect tissue heterogeneity. The EUD was calculated in two different ways: first, assuming a uniform tumor cell density within the tumor target; second, using FDG-PET activity (counts/cm 3 ) as a surrogate for tumor cell density at different parts of tumor to calculate the functional-imaging-weighted EUD (therefore will be labeled fEUD for convenience). The EUD calculation can be easily incorporated into the treatment planning process. For 28/31 patients, their fEUD and EUD differed by less than 6%. Twenty-one of these twenty-eight patients had tumor volumes 3 . In the three patients with larger tumor volume, the fEUD and EUD differed by 8%-14%. Incorporating information from PET imaging to represent tumor cell density in the EUD calculation is straightforward. This approach provides the opportunity to include heterogeneity in tumor function/metabolism into the EUD calculation. The difference between fEUD and EUD, i.e., whether including or not including the possible tumor cell density heterogeneity within tumor can be significant with large tumor volumes. Further research is needed to assess the usefulness of the fEUD concept in radiation treatment

  11. Palliative radiotherapy. Ranking within an interdisciplinary treatment concept in case of advanced tumor disease; Palliative Strahlentherapie. Rolle im interdisziplinaeren Behandlungskonzept bei fortgeschrittenem Tumorleiden

    Energy Technology Data Exchange (ETDEWEB)

    Seegenschmiedt, M.H. [Krupp Krankenanstalten Gemeinnuetzige GmbH, Essen (Germany). Klinik fuer Strahlentherapie und Nuklearmedizin

    1998-10-23

    Many tumor-induced symptoms can be alleviated by suitable irradiation in a direct, effective and sparing manner. The clinical response amounts to 80% and is independent of tumor histology. Careful diagnosis and accurate localisation of the causes of symptoms as well as exact therapy planning and execution are required. Based on individual dose planning harmonising single dosis and total dosis, pin-pointed definition of target areas, and application of modern planning and irradiation techniques, palliative radiotherapy is able to achieve long-term improvement with neglectible side-effects, sometimes within only a few days or weeks. It is a valuable part of a consistant therapy concept that is tailored to the individual needs of a patient, by cooperative action of experts from a variety of medical disciplines, intended to optimize the qulity of life of patients, and sometimes may exclude conventional radiotherapy. (orig./CB) [Deutsch] Viele tumorbedingten Symptome koennen mit Strahlentherapie kausal wirksam, effektiv und schonend behandelt werden. Das klinische Ansprechen betraegt 80% und ist unabhaengig von der Histologie des Tumors. Eine sorgfaeltige Indikationsstellung und genaue Lokalisation der Symptomursache sowie exakte Planung und Durchfuehrung der Strahlentherapie sind Bedingung. Mit einer individuellen Anpassung der Einzel- und Gesamtdosis, des Zielvolumens und dem Einsatz moderner Planungs- und Bestrahlungstechniken gelingt es, oft innerhalb weniger Tage bis Wochen eine langanhaltende Symptombesserung ohne wesentliche Nebenwirkungen zu erzielen. Die palliative Strahlentherapie ist dabei Teil eines Gesamtbehandlungskonzeptes, das interdisziplinaer abgestimmt ist und eine optimale Lebensqualitaet fuer den Tumorpatienten anstrebt, manchmal auch unter Verzicht auf eine Therapie. (orig.)

  12. On the atmospheric drag in orbit determination for low Earth orbit

    Science.gov (United States)

    Tang, Jingshi; Liu, Lin; Miao, Manqian

    2012-07-01

    The atmosphere model is always a major limitation for low Earth orbit (LEO) in orbit prediction and determination. The accelerometer can work around the non-gravitational perturbations in orbit determination, but it helps little to improve the atmosphere model or to predict the orbit. For certain satellites, there may be some specific software to handle the orbit problem. This solution can improve the orbit accuracy for both prediction and determination, yet it always contains empirical terms and is exclusive for certain satellites. This report introduces a simple way to handle the atmosphere drag for LEO, which does not depend on instantaneous atmosphere conditions and improves accuracy of predicted orbit. This approach, which is based on mean atmospheric density, is supported by two reasons. One is that although instantaneous atmospheric density is very complicated with time and height, the major pattern is determined by the exponential variation caused by hydrostatic equilibrium and periodic variation caused by solar radiation. The mean density can include the major variations while neglect other minor details. The other reason is that the predicted orbit is mathematically the result from integral and the really determinant factor is the mean density instead of instantaneous density for every time and spot. Using the mean atmospheric density, which is mainly determined by F10.7 solar flux and geomagnetic index, can be combined into an overall parameter B^{*} = C_{D}(S/m)ρ_{p_{0}}. The combined parameter contains several less accurate parameters and can be corrected during orbit determination. This approach has been confirmed in various LEO computations and an example is given below using Tiangong-1 spacecraft. Precise orbit determination (POD) is done using one-day GPS positioning data without any accurate a-priori knowledge on spacecraft or atmosphere conditions. Using the corrected initial state vector of the spacecraft and the parameter B^* from POD, the

  13. Orbit error characteristic and distribution of TLE using CHAMP orbit data

    Science.gov (United States)

    Xu, Xiao-li; Xiong, Yong-qing

    2018-02-01

    Space object orbital covariance data is required for collision risk assessments, but publicly accessible two line element (TLE) data does not provide orbital error information. This paper compared historical TLE data and GPS precision ephemerides of CHAMP to assess TLE orbit accuracy from 2002 to 2008, inclusive. TLE error spatial variations with longitude and latitude were calculated to analyze error characteristics and distribution. The results indicate that TLE orbit data are systematically biased from the limited SGP4 model. The biases can reach the level of kilometers, and the sign and magnitude are correlate significantly with longitude.

  14. An Orbit Propagation Software for Mars Orbiting Spacecraft

    Directory of Open Access Journals (Sweden)

    Young-Joo Song

    2004-12-01

    Full Text Available An orbit propagation software for the Mars orbiting spacecraft has been developed and verified in preparations for the future Korean Mars missions. Dynamic model for Mars orbiting spacecraft has been studied, and Mars centered coordinate systems are utilized to express spacecraft state vectors. Coordinate corrections to the Mars centered coordinate system have been made to adjust the effects caused by Mars precession and nutation. After spacecraft enters Sphere of Influence (SOI of the Mars, the spacecraft experiences various perturbation effects as it approaches to Mars. Every possible perturbation effect is considered during integrations of spacecraft state vectors. The Mars50c gravity field model and the Mars-GRAM 2001 model are used to compute perturbation effects due to Mars gravity field and Mars atmospheric drag, respectively. To compute exact locations of other planets, JPL's DE405 ephemerides are used. Phobos and Deimos's ephemeris are computed using analytical method because their informations are not released with DE405. Mars Global Surveyor's mapping orbital data are used to verify the developed propagator performances. After one Martian day propagation (12 orbital periods, the results show about maximum ±5 meter errors, in every position state components(radial, cross-track and along-track, when compared to these from the Astrogator propagation in the Satellite Tool Kit. This result shows high reliability of the developed software which can be used to design near Mars missions for Korea, in future.

  15. Burn Delay Analysis of the Lunar Orbit Insertion for Korea Pathfinder Lunar Orbiter

    Science.gov (United States)

    Bae, Jonghee; Song, Young-Joo; Kim, Young-Rok; Kim, Bangyeop

    2017-12-01

    The first Korea lunar orbiter, Korea Pathfinder Lunar Orbiter (KPLO), has been in development since 2016. After launch, the KPLO will execute several maneuvers to enter into the lunar mission orbit, and will then perform lunar science missions for one year. Among these maneuvers, the lunar orbit insertion (LOI) is the most critical maneuver because the KPLO will experience an extreme velocity change in the presence of the Moon’s gravitational pull. However, the lunar orbiter may have a delayed LOI burn during operation due to hardware limitations and telemetry delays. This delayed burn could occur in different captured lunar orbits; in the worst case, the KPLO could fly away from the Moon. Therefore, in this study, the burn delay for the first LOI maneuver is analyzed to successfully enter the desired lunar orbit. Numerical simulations are performed to evaluate the difference between the desired and delayed lunar orbits due to a burn delay in the LOI maneuver. Based on this analysis, critical factors in the LOI maneuver, the periselene altitude and orbit period, are significantly changed and an additional delta-V in the second LOI maneuver is required as the delay burn interval increases to 10 min from the planned maneuver epoch.

  16. Design concept definition study for an improved shuttle waste collection subsystem

    Science.gov (United States)

    1984-01-01

    A no-risk approach for developing an Improved Waste Collection Subsystem (WCS) for the shuttle orbiter is described. The GE Improved WCS Concept builds on the experience of 14 Shuttle missions with over 400 man-days of service. This concept employs the methods of the existing flight-proven mature design, augmenting them to eliminate foreseen difficulties and to fully comply with the design requirements. The GE Improved WCS Concept includes separate storage for used wipes. Compaction of the wipes provides a solution to the capacity problem, fully satisfying the 210 man-day storage requirement. The added feature of in-flight serviceable storage space for the wipes creates a variable capacity feature which affords redundancy in the event of wipes compaction system failure. Addition of features permitting in-flight servicing of the feces storage tank creates a variable capacity WCS with easier post-flight servicing to support rapid turnaround of the Shuttle orbiter. When these features are combined with a vacuum pump to evacuate wipes and fecal storage tanks through replaceable odor/bacteria filters to the cabin, the GE Improved WCS satisfies the known requirements for Space Station use, including no venting to space.

  17. GLONASS Orbits in Teqc: Methodology and Future Extension for Using SP3 Orbits

    Science.gov (United States)

    Estey, L.; Wier, S.

    2011-12-01

    UNAVCO's teqc software package provides translation of a wide variety of GNSS receiver formats, metadata editing (either during translation to RINEX or on existing RINEX files), time-windowing and epoch decimation editing, and quality check (qc) analysis. Teqc is used extensively in GNSS pre-processing, and is designed to handle mixed satellite constellations, such as GPS, GLONASS, Galileo, and SBAS. The latest release of teqc adds GLONASS orbit calculations using GLONASS broadcast navigation messages, read from RINEX file format, during qc. The ephemerides for each GLONASS SV have time and orbit position in Earth-centered, Earth-fixed x, y, and z coordinates. Following Schenewerk [2003], we use trigonometric interpolation, essentially a fit of a partial sum of the Fourier series for each time-varying cartesian orbital component, allowing estimates of orbit positions at most GLONASS observation times. Tests show the interpolated GLONASS orbits made from the broadcast messages diverge from final orbits little more than the same differences using GPS orbits computed from their broadcast messages. Since GLONASS ephemerides do not use Keplerian orbital elements, GLONASS SV orbits can only be interpolated using this method for time intervals when an adequate sequence of ephemerides are available. For typical daily navigation messages collected at a single sit, when a GLONASS SV is in view less than three hours, that SV's signals are generally not used by teqc due to less precise orbit positions. Teqc quality control including SV position can now use GPS alone, GLONASS alone, or the joint solution. Future work will extend teqc to use SP3 format files, such as the IGS final orbit files, and SBAS data, which have broadcast ephemerides with elements similar to GLONASS.

  18. Orbital approach to the electronic structure of solids

    CERN Document Server

    Canadell, Enric; Iung, Christophe

    2012-01-01

    This book provides an intuitive yet sound understanding of how structure and properties of solids may be related. The natural link is provided by the band theory approach to the electronic structure of solids. The chemically insightful concept of orbital interaction and the essential machinery of band theory are used throughout the book to build links between the crystal and electronic structure of periodic systems. In such a way, it is shown how important tools for understandingproperties of solids like the density of states, the Fermi surface etc. can be qualitatively sketched and used to ei

  19. Nontraumatic orbital roof encephalocele.

    Science.gov (United States)

    Hoang, Amber; Maugans, Todd; Ngo, Thang; Ikeda, Jamie

    2017-02-01

    Intraorbital meningoencephaloceles occur most commonly as a complication of traumatic orbital roof fractures. Nontraumatic congenital orbital meningoncephaloceles are very rare, with most secondary to destructive processes affecting the orbit and primary skull defects. Treatment for intraorbital meningoencephaloceles is surgical repair, involving the excision of herniated brain parenchyma and meninges and reconstruction of the osseous defect. Most congenital lesions present in infancy with obvious globe and orbital deformities; we report an orbital meningoencephalocele in a 3-year-old girl who presented with ptosis. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  20. Modeling evolutionary dynamics of epigenetic mutations in hierarchically organized tumors.

    Directory of Open Access Journals (Sweden)

    Andrea Sottoriva

    2011-05-01

    Full Text Available The cancer stem cell (CSC concept is a highly debated topic in cancer research. While experimental evidence in favor of the cancer stem cell theory is apparently abundant, the results are often criticized as being difficult to interpret. An important reason for this is that most experimental data that support this model rely on transplantation studies. In this study we use a novel cellular Potts model to elucidate the dynamics of established malignancies that are driven by a small subset of CSCs. Our results demonstrate that epigenetic mutations that occur during mitosis display highly altered dynamics in CSC-driven malignancies compared to a classical, non-hierarchical model of growth. In particular, the heterogeneity observed in CSC-driven tumors is considerably higher. We speculate that this feature could be used in combination with epigenetic (methylation sequencing studies of human malignancies to prove or refute the CSC hypothesis in established tumors without the need for transplantation. Moreover our tumor growth simulations indicate that CSC-driven tumors display evolutionary features that can be considered beneficial during tumor progression. Besides an increased heterogeneity they also exhibit properties that allow the escape of clones from local fitness peaks. This leads to more aggressive phenotypes in the long run and makes the neoplasm more adaptable to stringent selective forces such as cancer treatment. Indeed when therapy is applied the clone landscape of the regrown tumor is more aggressive with respect to the primary tumor, whereas the classical model demonstrated similar patterns before and after therapy. Understanding these often counter-intuitive fundamental properties of (non-hierarchically organized malignancies is a crucial step in validating the CSC concept as well as providing insight into the therapeutical consequences of this model.

  1. E-Orbit Functions

    Directory of Open Access Journals (Sweden)

    Jiri Patera

    2008-01-01

    Full Text Available We review and further develop the theory of $E$-orbit functions. They are functions on the Euclidean space $E_n$ obtained from the multivariate exponential function by symmetrization by means of an even part $W_{e}$ of a Weyl group $W$, corresponding to a Coxeter-Dynkin diagram. Properties of such functions are described. They are closely related to symmetric and antisymmetric orbit functions which are received from exponential functions by symmetrization and antisymmetrization procedure by means of a Weyl group $W$. The $E$-orbit functions, determined by integral parameters, are invariant withrespect to even part $W^{aff}_{e}$ of the affine Weyl group corresponding to $W$. The $E$-orbit functions determine a symmetrized Fourier transform, where these functions serve as a kernel of the transform. They also determine a transform on a finite set of points of the fundamental domain $F^{e}$ of the group $W^{aff}_{e}$ (the discrete $E$-orbit function transform.

  2. Congenital orbital encephalocele, orbital dystopia, and exophthalmos.

    Science.gov (United States)

    Hwang, Kun; Kim, Han Joon

    2012-07-01

    We present here an exceedingly rare variant of a nonmidline basal encephalocele of the spheno-orbital type, and this was accompanied with orbital dystopia in a 56-year-old man. On examination, his left eye was located more inferolaterally than his right eye, and the patient said this had been this way since his birth. The protrusion of his left eye was aggravated when he is tired. His naked visual acuity was 0.7/0.3, and the ocular pressure was 14/12 mm Hg. The exophthalmometry was 10/14 to 16 mm. His eyeball motion was not restricted, yet diplopia was present in all directions. The distance from the midline to the medial canthus was 20/15 mm. The distance from the midline to the midpupillary line was 35/22 mm. The vertical dimension of the palpebral fissure was 12/9 mm. The height difference of the upper eyelid margin was 11 mm, and the height difference of the lower eyelid margin was 8 mm. Facial computed tomography and magnetic resonance imaging showed left sphenoid wing hypoplasia and herniation of the left anterior temporal pole and dura mater into the orbit, and this resulted into left exophthalmos and encephalomalacia in the left anterior temporal pole. To the best of our knowledge, our case is the second case of basal encephalocele and orbital dystopia.

  3. Inverse engineering for fast transport and spin control of spin-orbit-coupled Bose-Einstein condensates in moving harmonic traps

    Science.gov (United States)

    Chen, Xi; Jiang, Ruan-Lei; Li, Jing; Ban, Yue; Sherman, E. Ya.

    2018-01-01

    We investigate fast transport and spin manipulation of tunable spin-orbit-coupled Bose-Einstein condensates in a moving harmonic trap. Motivated by the concept of shortcuts to adiabaticity, we design inversely the time-dependent trap position and spin-orbit-coupling strength. By choosing appropriate boundary conditions we obtain fast transport and spin flip simultaneously. The nonadiabatic transport and relevant spin dynamics are illustrated with numerical examples and compared with the adiabatic transport with constant spin-orbit-coupling strength and velocity. Moreover, the influence of nonlinearity induced by interatomic interaction is discussed in terms of the Gross-Pitaevskii approach, showing the robustness of the proposed protocols. With the state-of-the-art experiments, such an inverse engineering technique paves the way for coherent control of spin-orbit-coupled Bose-Einstein condensates in harmonic traps.

  4. Measurement of orbital volume by computed tomography. Especially on the growth of orbit

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Minoru [Fukushima Medical Coll. (Japan)

    2000-10-01

    Using reconstructed X-ray computed tomography (CT) images of serial coronal sections, we measured the orbital volume and studied its changes with age. The subjects consisted of 109 patients (74 males, 35 females) who had undergone X-ray CT. After the reproducibility of orbital volume measurements and laterality in individuals were confirmed, the relation between the orbital volume and the age, sex, weight, and interlateral orbital rim distance were examined. The difference between two measurements in the same patients was 0.4% for measured volume, which showed the reproducibility of this measurement to be good. The laterality in individuals was 0.06 cm{sup 3}: this difference was very small and not significant. The orbital volume showed no unbalance between the right and left at any stage of growth. Both the height and the interlateral orbital rim distance had a strong correlation with the orbital volume. Referring to the relation between age and orbital volume, a strong correlation with an almost identical approximate equation was obtained for both sexes under 12 years of age. Presumably, the rapid growth of the orbit comes to an end by 15 years of age in males and 11 years in females. This means that more than 95% growth of adults has already been completed in the first half of the teens. The mean orbital volume in adult Japanese is 23.6{+-}2.0 (mean{+-}standard deviation) cm{sup 3} in males and 20.9{+-}1.3 cm{sup 3} in females. (author)

  5. Measurement of orbital volume by computed tomography. Especially on the growth of orbit

    International Nuclear Information System (INIS)

    Furuta, Minoru

    2000-01-01

    Using reconstructed X-ray computed tomography (CT) images of serial coronal sections, we measured the orbital volume and studied its changes with age. The subjects consisted of 109 patients (74 males, 35 females) who had undergone X-ray CT. After the reproducibility of orbital volume measurements and laterality in individuals were confirmed, the relation between the orbital volume and the age, sex, weight, and interlateral orbital rim distance were examined. The difference between two measurements in the same patients was 0.4% for measured volume, which showed the reproducibility of this measurement to be good. The laterality in individuals was 0.06 cm 3 : this difference was very small and not significant. The orbital volume showed no unbalance between the right and left at any stage of growth. Both the height and the interlateral orbital rim distance had a strong correlation with the orbital volume. Referring to the relation between age and orbital volume, a strong correlation with an almost identical approximate equation was obtained for both sexes under 12 years of age. Presumably, the rapid growth of the orbit comes to an end by 15 years of age in males and 11 years in females. This means that more than 95% growth of adults has already been completed in the first half of the teens. The mean orbital volume in adult Japanese is 23.6±2.0 (mean±standard deviation) cm 3 in males and 20.9±1.3 cm 3 in females. (author)

  6. Stable low-altitude orbits around Ganymede considering a disturbing body in a circular orbit

    Science.gov (United States)

    Cardoso dos Santos, J.; Carvalho, J. P. S.; Vilhena de Moraes, R.

    2014-10-01

    Some missions are being planned to visit Ganymede like the Europa Jupiter System Mission that is a cooperation between NASA and ESA to insert the spacecraft JGO (Jupiter Ganymede Orbiter) into Ganymedes orbit. This comprehension of the dynamics of these orbits around this planetary satellite is essential for the success of this type of mission. Thus, this work aims to perform a search for low-altitude orbits around Ganymede. An emphasis is given in polar orbits and it can be useful in the planning of space missions to be conducted around, with respect to the stability of orbits of artificial satellites. The study considers orbits of artificial satellites around Ganymede under the influence of the third-body (Jupiter's gravitational attraction) and the polygenic perturbations like those due to non-uniform distribution of mass (J_2 and J_3) of the main body. A simplified dynamic model for these perturbations is used. The Lagrange planetary equations are used to describe the orbital motion of the artificial satellite. The equations of motion are developed in closed form to avoid expansions in eccentricity and inclination. The results show the argument of pericenter circulating. However, low-altitude (100 and 150 km) polar orbits are stable. Another orbital elements behaved variating with small amplitudes. Thus, such orbits are convenient to be applied to future space missions to Ganymede. Acknowledgments: FAPESP (processes n° 2011/05671-5, 2012/12539-9 and 2012/21023-6).

  7. Titan Orbiter Aerorover Mission

    Science.gov (United States)

    Sittler Jr., E. C.; Acuna, M.; Burchell, M. J.; Coates, A.; Farrell, W.; Flasar, M.; Goldstein, B. E.; Gorevan, S.; Hartle, R. E.; Johnson, W. T. K.

    2001-01-01

    We propose a combined Titan orbiter and Titan Aerorover mission with an emphasis on both in situ and remote sensing measurements of Titan's surface, atmosphere, ionosphere, and magnetospheric interaction. The biological aspect of the Titan environment will be emphasized by the mission (i.e., search for organic materials which may include simple organics to 'amono' analogues of amino acids and possibly more complex, lightening detection and infrared, ultraviolet, and charged particle interactions with Titan's surface and atmosphere). An international mission is assumed to control costs. NASA will provide the orbiter, launch vehicle, DSN coverage and operations, while international partners will provide the Aerorover and up to 30% of the cost for the scientific instruments through collaborative efforts. To further reduce costs we propose a single PI for orbiter science instruments and a single PI for Aerorover science instruments. This approach will provide single command/data and power interface between spacecraft and orbiter instruments that will have redundant central DPU and power converter for their instruments. A similar approach could be used for the Aerorover. The mission profile will be constructed to minimize conflicts between Aerorover science, orbiter radar science, orbiter radio science, orbiter imaging science, and orbiter fields and particles (FP) science. Additional information is contained in the original extended abstract.

  8. Harmonically excited orbital variations

    International Nuclear Information System (INIS)

    Morgan, T.

    1985-01-01

    Rephrasing the equations of motion for orbital maneuvers in terms of Lagrangian generalized coordinates instead of Newtonian rectangular cartesian coordinates can make certain harmonic terms in the orbital angular momentum vector more readily apparent. In this formulation the equations of motion adopt the form of a damped harmonic oscillator when torques are applied to the orbit in a variationally prescribed manner. The frequencies of the oscillator equation are in some ways unexpected but can nonetheless be exploited through resonant forcing functions to achieve large secular variations in the orbital elements. Two cases are discussed using a circular orbit as the control case: (1) large changes in orbital inclination achieved by harmonic excitation rather than one impulsive velocity change, and (2) periodic and secular changes to the longitude of the ascending node using both stable and unstable excitation strategies. The implications of these equations are also discussed for both artificial satellites and natural satellites. For the former, two utilitarian orbits are suggested, each exploiting a form of harmonic excitation. 5 refs

  9. Spin-orbit torques from interfacial spin-orbit coupling for various interfaces

    Science.gov (United States)

    Kim, Kyoung-Whan; Lee, Kyung-Jin; Sinova, Jairo; Lee, Hyun-Woo; Stiles, M. D.

    2017-09-01

    We use a perturbative approach to study the effects of interfacial spin-orbit coupling in magnetic multilayers by treating the two-dimensional Rashba model in a fully three-dimensional description of electron transport near an interface. This formalism provides a compact analytic expression for current-induced spin-orbit torques in terms of unperturbed scattering coefficients, allowing computation of spin-orbit torques for various contexts, by simply substituting scattering coefficients into the formulas. It applies to calculations of spin-orbit torques for magnetic bilayers with bulk magnetism, those with interface magnetism, a normal-metal/ferromagnetic insulator junction, and a topological insulator/ferromagnet junction. It predicts a dampinglike component of spin-orbit torque that is distinct from any intrinsic contribution or those that arise from particular spin relaxation mechanisms. We discuss the effects of proximity-induced magnetism and insertion of an additional layer and provide formulas for in-plane current, which is induced by a perpendicular bias, anisotropic magnetoresistance, and spin memory loss in the same formalism.

  10. Orbit-attitude coupled motion around small bodies: Sun-synchronous orbits with Sun-tracking attitude motion

    Science.gov (United States)

    Kikuchi, Shota; Howell, Kathleen C.; Tsuda, Yuichi; Kawaguchi, Jun'ichiro

    2017-11-01

    The motion of a spacecraft in proximity to a small body is significantly perturbed due to its irregular gravity field and solar radiation pressure. In such a strongly perturbed environment, the coupling effect of the orbital and attitude motions exerts a large influence that cannot be neglected. However, natural orbit-attitude coupled dynamics around small bodies that are stationary in both orbital and attitude motions have yet to be observed. The present study therefore investigates natural coupled motion that involves both a Sun-synchronous orbit and Sun-tracking attitude motion. This orbit-attitude coupled motion enables a spacecraft to maintain its orbital geometry and attitude state with respect to the Sun without requiring active control. Therefore, the proposed method can reduce the use of an orbit and attitude control system. This paper first presents analytical conditions to achieve Sun-synchronous orbits and Sun-tracking attitude motion. These analytical solutions are then numerically propagated based on non-linear coupled orbit-attitude equations of motion. Consequently, the possibility of implementing Sun-synchronous orbits with Sun-tracking attitude motion is demonstrated.

  11. Tumor maligno indiferenciado disseminado. Diagnóstico ao exame oftalmológico: relato de um caso Metastatic undifferentiated malignant tumor: report of a case

    Directory of Open Access Journals (Sweden)

    Henrique Shiguekiyo Kikuta

    2001-08-01

    Full Text Available Objetivo: Demonstrar a importância da anamnese e do exame físico geral nas afecções orbitárias, como orientadores do diagnóstico e do tratamento adequados. Métodos: Anamnese, exame físico geral e oftalmológico e exames complementares: radiografia de tórax, ultra-sonografia abdominal e pélvica, tomografia computadorizada de órbita; e procedimentos de biópsia punção aspirativa de massa orbitária, biópsia excisional de nódulo esternal e respectivos exames de citologia, histologia e imuno-histoquímico. Resultados: A ultra-sonografia pélvica demonstrou a presença de grande massa em anexo, provavelmente o foco primário. A radiografia de tórax revelou massas provavelmente metastáticas. O resultado do exame histopatológico das biópsias de massa retrobulbar e nódulo esternal foi compatível com neoplasia maligna indiferenciada. Conclusões: Este relato ressalta a importância da anamnese e do exame físico geral nas afecções orbitarias, orientando o diagnóstico e o tratamento adequado, pois embora a paciente apresentasse múltiplas metástases, foram os sinais oftalmológicos que a conduziram ao médico.Purpose: To demonstrate the importance of clinical history and general physical examination in orbital affections as guides for correction of and early diagnosis allowing adequate treatment. Methods: Clinical history, ophthalmologic and general physical examination and complementary examinations: Chest X-ray, pelvic and abdominal ultrasonography, orbital computerized tomography; fine needle aspiration biopsy of tumor, orbitary procedures, excisional biopsy of sternal nodule and retrospective cytologic, histologic and imunohistochenical examinations. Results: Pelvic ultrasonography demonstrated the presence of a large tumor in anexus, probably the primary focus. In the chest X-ray there is evidence of metastatic mass. The histopathological findings of both retrobulbar mass and sternal nodule were compatible with

  12. Mars Mission Concepts: SAR and Solar Electric Propulsion

    Science.gov (United States)

    Elsperman, M.; Klaus, K.; Smith, D. B.; Clifford, S. M.; Lawrence, S. J.

    2012-12-01

    Introduction: The time has come to leverage technology advances (including advances in autonomous operation and propulsion technology) to reduce the cost and increase the flight rate of planetary missions, while actively developing a scientific and engineering workforce to achieve national space objectives. Mission Science at Mars: A SAR imaging radar offers an ability to conduct high resolution investigations of the shallow (Models uniquely useful for exploration planning and science purposes. Since the SAR and the notional high-resolution stereo imaging system would be huge data volume producers - to maximize the science return we are currently considering the usage of laser communications systems; this notional spacecraft represents one pathway to evaluate the utility of laser communications in planetary exploration while providing useful science return.. Mission Concept: Using a common space craft for multiple missions reduces costs. Solar electric propulsion (SEP) provides the flexibility required for multiple mission objectives. SEP provides the greatest payload advantage albeit at the sacrifice of mission time. Our concept involves using a SEP enabled space craft (Boeing 702SP) with a highly capable SAR imager that also conducts autonomous rendezvous and docking experiments accomplished from Mars orbit. Our concept of operations is to launch on May 5, 2018 using a launch vehicle with 2000kg launch capacity with a C3 of 7.4. After reaching Mars it takes 145 days to spiral down to a 250 km orbit above the surface of Mars when Mars SAR operations begin. Summary/Conclusions: A robust and compelling Mars mission can be designed to meet the 2018 Mars launch window opportunity. Using advanced in-space power and propulsion technologies like High Power Solar Electric Propulsion provides enormous mission flexibility to execute the baseline science mission and conduct necessary Mars Sample Return Technology Demonstrations in Mars orbit on the same mission. An

  13. MR-Guided Laser-Induced Thermotherapy of the Infratemporal Fossa and Orbit in Malignant Chondrosarcoma via a Modified Technique

    International Nuclear Information System (INIS)

    Vogl, Thomas J.; Mack, Martin G.; Straub, Ralf; Eichler, Katrin; Zangos, Stephan

    2001-01-01

    A 76-year-old patient presented with a recurrent mass of a malignant chondrosarcoma in the right infratemporal fossa and in the left maxillary sinus with orbital invasion. The patient was treated with a palliative intention with MR-guided laser-induced thermotherapy using a modified applicator technique. Following treatment clinical symptoms improved and MRI revealed complete laser-induced tumor necrosis

  14. Congenital orbital teratoma

    OpenAIRE

    Aiyub, Shereen; Chan, Weng Onn; Szetu, John; Sullivan, Laurence J; Pater, John; Cooper, Peter; Selva, Dinesh

    2013-01-01

    We present a case of mature congenital orbital teratoma managed with lid-sparing exenteration and dermis fat graft. This is a case report on the management of congenital orbital teratoma. A full-term baby was born in Fiji with prolapsed right globe which was surrounded by a nonpulsatile, cystic mass. Clinical and imaging features were consistent with congenital orbital teratoma. Due to limited surgical expertise, the patient was transferred to Adelaide, Australia for further management. The p...

  15. [Simultaneous repairing defects of orbital floor and palate with the modified temporalis muscle flap after the maxillectomy].

    Science.gov (United States)

    Zhong, Q; Huang, Z G; Fang, J G; Chen, X J; Chen, X H; Hou, L Z; Li, P D; Ma, H Z; He, S Z

    2016-09-07

    Objective: To evaluate the outcome of one-stage reconstruction of maxillary and orbital defects with modified temporalis muscle flap (TMF) following the removal of malignant neoplasms. Methods: In this retrospective study, 15 patients underwent the reconstruction of defects of orbital floor and palate after maxillectomy for malignant tumor were included from June 2008 to June 2014. The modified temporalis muscle flap was used to repair the defects after surgery, and functional outcomes were analyzed. Results: All the patients were followed up for 12-81 months. Three cases of them received preoperative radiotherapy and 12 cases underwent postoperative radiotherapy. All flaps were survived. Epithelization of the tissues in oral and nasal cavity was completed in 4-6 weeks. Good functional reconstruction on swallowing and speaking functional results were achieved with maxillary and orbital reconstruction and no secondary deformity of external nose was observed. The eye positions in all cases were normal. Diplopia, diminution and loss of vision were not found. Conclusion: The modified TMF can be used for simultaneous reconstruction for the defects of orbital floor and palate after maxillectomy in patients whom free tissue flap can not be applied to, showing better cosmetic and functional results.

  16. Optical vortex symmetry breakdown and decomposition of the orbital angular momentum of light beams.

    Science.gov (United States)

    Bekshaev, A Ya; Soskin, M S; Vasnetsov, M V

    2003-08-01

    Two forms of the transverse energy circulation within plane-polarized paraxial light beams are specified: one inherent in wave-front singularities (optical vortices) and the other peculiar to astigmatism and asymmetry of beams with a smooth wave front. As quantitative measures of these energy flow components, the concepts of vortex and asymmetry parts of a beam's orbital angular momentum are introduced and their definitions are proposed on the basis of beam intensity moments. The properties and physical meaning of these concepts are analyzed, and their use for the study of transformations of optical vortices is demonstrated.

  17. Isolated eyeball metastasis of non-seminomatous germ cell testicular tumor.

    Science.gov (United States)

    Bojanić, Nebojsa; Nale, Djordje; Mićić, Sava; Janicić, Aleksandar; Vuksanović, Aleksandar; Vuković, Ivan

    2011-11-01

    Testicular tumors most frequently metastasize to regional lymph nodes. Non-seminomatous tumor metastasis of testicle (NSGCTT) to the eyeball is rare. We presented a 24-year old man, referred to the ophthalmologist due to acute pain and abrupt loss of sight in the left eye accompanied by its enlargement. Orbital and endocranial computerized tomography (CT) was carried out, indicating the tumor in the left eye. His previous medical history provided the information that the right testicle was painlessly enlarged for 8 months. Ultrasonography showed a completely tumorously altered testis. Abdominal and chest CT failed to reveal any secondary deposits in visceral organs and lymph glands. Tumor markers (AFP - alpha-fetoproteins, beta hCG - human choronic gonadotropin beta) were elevated. Right radical orchiactomy was performed (showed NSGCTT), followed by polychemotherapy with cisplatinum 100 mg/m2, etoposide 120 mg/m2, bleomycin 15 mg/m2 (PEB x 4), resulting in normalization of tumor marker values and significant regression of the left eyeball. Next, the left eye enucleation and ocular prosthesis implantation was carried out. Pathohistological evaluation indicated fibrosis and necrosis only. In a 5-year follow-up period, the patient was free of recurrence. Isolated hematogenous metastasis of the NSGCTT to the eye is rare. In our case, the left eye was the only metastatic localization. After chemotherapy and eye enucleation the patient was in a 4-year follow-up period free of the recurrence.

  18. Future orbital transfer vehicle technology study. Volume 2: Technical report

    Science.gov (United States)

    Davis, E. E.

    1982-01-01

    Missions for future orbit transfer vehicles (1995-2010) are identified and the technology, operations and vehicle concepts that satisfy the transportation requirements are defined. Comparison of reusable space and ground based LO2/LH2 OTV's was made. Both vehicles used advanced space engines and aero assist capability. The SB OTV provided advantages in life cycle cost, performance and potential for improvement. Comparison of an all LO2/LH2 OTV fleet with a fleet of LO2/LH2 OTVs and electric OTV's was also made. The normal growth technology electric OTV used silicon cells with heavy shielding and argon ion thrusters. This provided a 23% advantage in total transportation cost. The impact of accelerated technology was considered in terms of improvements in performance and cost effectiveness. The accelerated technology electric vehicle used GaAs cells and annealing but did not result in the mixed fleet being any cheaper than an all LO2/LH2 OTV fleet. It is concluded that reusable LO2/LH2 OTV's can serve all general purpose cargo roles between LEO and GEO for the forseeable future. The most significant technology for the second generation vehicle would be space debris protection, on-orbit propellant storage and transfer and on-orbit maintenance capability.

  19. Searching for Orbits with Minimum Fuel Consumption for Station-Keeping Maneuvers: An Application to Lunisolar Perturbations

    Directory of Open Access Journals (Sweden)

    Antonio Fernando Bertachini de Almeida Prado

    2013-01-01

    Full Text Available The present paper has the goal of developing a new criterion to search for orbits that minimize the fuel consumption for station-keeping maneuvers. This approach is based on the integral over the time of the perturbing forces. This integral measures the total variation of velocity caused by the perturbations in the spacecraft, which corresponds to the equivalent variation of velocity that an engine should deliver to the spacecraft to compensate the perturbations and to keep its orbit Keplerian all the time. This integral is a characteristic of the orbit and the set of perturbations considered and does not depend on the type of engine used. In this sense, this integral can be seen as a criterion to select the orbit of the spacecraft. When this value becomes larger, more consumption of fuel is required for the station keeping, and, in this sense, less interesting is the orbit. This concept can be applied to any perturbation. In the present research, as an example, the perturbation caused by a third body is considered. Then, numerical simulations considering the effects of the Sun and the Moon in a satellite around the Earth are shown to exemplify the method.

  20. Topology of tokamak orbits

    International Nuclear Information System (INIS)

    Rome, J.A.; Peng, Y.K.M.

    1978-09-01

    Guiding center orbits in noncircular axisymmetric tokamak plasmas are studied in the constants of motion (COM) space of (v, zeta, psi/sub m/). Here, v is the particle speed, zeta is the pitch angle with respect to the parallel equilibrium current, J/sub parallels/, and psi/sub m/ is the maximum value of the poloidal flux function (increasing from the magnetic axis) along the guiding center orbit. Two D-shaped equilibria in a flux-conserving tokamak having β's of 1.3% and 7.7% are used as examples. In this space, each confined orbit corresponds to one and only one point and different types of orbits (e.g., circulating, trapped, stagnation and pinch orbits) are represented by separate regions or surfaces in the space. It is also shown that the existence of an absolute minimum B in the higher β (7.7%) equilibrium results in a dramatically different orbit topology from that of the lower β case. The differences indicate the confinement of additional high energy (v → c, within the guiding center approximation) trapped, co- and countercirculating particles whose orbit psi/sub m/ falls within the absolute B well

  1. Correlation between the 2-Dimensional Extent of Orbital Defects and the 3-Dimensional Volume of Herniated Orbital Content in Patients with Isolated Orbital Wall Fractures

    Directory of Open Access Journals (Sweden)

    Jong Hyun Cha

    2017-01-01

    Full Text Available BackgroundThe purpose of this study was to assess the correlation between the 2-dimensional (2D extent of orbital defects and the 3-dimensional (3D volume of herniated orbital content in patients with an orbital wall fracture.MethodsThis retrospective study was based on the medical records and radiologic data of 60 patients from January 2014 to June 2016 for a unilateral isolated orbital wall fracture. They were classified into 2 groups depending on whether the fracture involved the inferior wall (group I, n=30 or the medial wall (group M, n=30. The 2D area of the orbital defect was calculated using the conventional formula. The 2D extent of the orbital defect and the 3D volume of herniated orbital content were measured with 3D image processing software. Statistical analysis was performed to evaluate the correlations between the 2D and 3D parameters.ResultsVarying degrees of positive correlation were found between the 2D extent of the orbital defects and the 3D herniated orbital volume in both groups (Pearson correlation coefficient, 0.568−0.788; R2=32.2%−62.1%.ConclusionsBoth the calculated and measured 2D extent of the orbital defects showed a positive correlation with the 3D herniated orbital volume in orbital wall fractures. However, a relatively large volume of herniation (>0.9 cm3 occurred not infrequently despite the presence of a small orbital defect (<1.9 cm2. Therefore, estimating the 3D volume of the herniated content in addition to the 2D orbital defect would be helpful for determining whether surgery is indicated and ensuring adequate surgical outcomes.

  2. Neonatal orbital abscess

    Directory of Open Access Journals (Sweden)

    Khalil M Al-Salem

    2014-01-01

    Full Text Available Orbital complications due to ethmoiditis are rare in neonates. A case of orbital abscess due to acute ethmoiditis in a 28-day-old girl is presented. A Successful outcome was achieved following antimicrobial therapy alone; spontaneous drainage of the abscess occurred from the lower lid without the need for surgery. From this case report, we intend to emphasize on eyelid retraction as a sign of neonatal orbital abscess, and to review all the available literature of similar cases.

  3. Overview: Solar Electric Propulsion Concept Designs for SEP Technology Demonstration Mission

    Science.gov (United States)

    Mcguire, Melissa L.; Hack, Kurt J.; Manzella, David; Herman, Daniel

    2014-01-01

    JPC presentation of the Concept designs for NASA Solar Electric Propulsion Technology Demonstration mission paper. Multiple Solar Electric Propulsion Technology Demonstration Missions were developed to assess vehicle performance and estimated mission cost. Concepts ranged from a 10,000 kg spacecraft capable of delivering 4000 kg of payload to one of the Earth Moon Lagrange points in support of future human-crewed outposts to a 180 kg spacecraft capable of performing an asteroid rendezvous mission after launched to a geostationary transfer orbit as a secondary payload.

  4. METRIC: A Dedicated Earth-Orbiting Spacecraft for Investigating Gravitational Physics and the Space Environment

    Directory of Open Access Journals (Sweden)

    Roberto Peron

    2017-07-01

    Full Text Available A dedicated mission in low Earth orbit is proposed to test predictions of gravitational interaction theories and to directly measure the atmospheric density in a relevant altitude range, as well as to provide a metrological platform able to tie different space geodesy techniques. The concept foresees a small spacecraft to be placed in a dawn-dusk eccentric orbit between 450 and 1200 km of altitude. The spacecraft will be tracked from the ground with high precision, and a three-axis accelerometer package on-board will measure the non-gravitational accelerations acting on its surface. Estimates of parameters related to fundamental physics and geophysics should be obtained by a precise orbit determination, while the accelerometer data will be instrumental in constraining the atmospheric density. Along with the mission scientific objectives, a conceptual configuration is described together with an analysis of the dynamical environment experienced by the spacecraft and the accelerometer.

  5. The Bering small vehicle asteroid mission concept

    DEFF Research Database (Denmark)

    Michelsen, Rene; Andersen, Anja; Haack, Henning

    2004-01-01

    targets. The dilemma obviously being the resolution versus distance and the statistics versus DeltaV requirements. Using advanced instrumentation and onboard autonomy, we have developed a space mission concept whose goal is to map the flux, size, and taxonomy distributions of asteroids. The main focus....... Although the telescope based research offers precise orbital information, it is limited to the brighter, larger objects, and taxonomy as well as morphology resolution is limited. Conversely, dedicated missions offer detailed surface mapping in radar, visual, and prompt gamma, but only for a few selected......The study of asteroids is traditionally performed by means of large Earth based telescopes, by means of which orbital elements and spectral properties are acquired. Space borne research, has so far been limited to a few occasional flybys and a couple of dedicated flights to a single selected target...

  6. Tumor sterilization dose and radiation induced change of the brain tissue in radiotherapy of brain tumors

    International Nuclear Information System (INIS)

    Yoshii, Yoshihiko; Maki, Yutaka; Takano, Shingo

    1987-01-01

    Ninety-seven patients with brain tumors (38 gliomas, 26 brain metastases, 18 sellar tumors, 15 others) were treated by cobalt gamma ray or proton radiotherapy. In this study, normal brain injury due to radiation was analysed in terms of time-dose-fractionation (TDF), nominal standard dose (NSD) by the Ellis formula and NeuNSD by a modification in which the N exponent was -0.44 and the T exponent was -0.06. Their calculated doses were analysed in relationship to the normal brain radiation induced change (RIC) and the tumor sterilization dose. All brain tumors with an exception of many patients with brain metastases were received a surgical extirpation subtotally or partially prior to radiotherapy. And all patients with glioma and brain metastasis received also immuno-chemotherapy in the usual manner during radiotherapy. The calculated dose expressed by NeuNSD and TDF showed a significant relationship between a therapeutic dose and a postradiation time in terms of the appearance of RIC. It was suggested that RIC was caused by a dose over 800 in NeuNSD and a dose over 70 in TDF. Furthermore, it was suggested that an aged patient and a patient who had the vulnerable brain tissue to radiation exposure in the irradiated field had the high risk of RIC. On the other hand, our results suggested that the tumor sterilization dose should be over 1,536 NeuNSD and the irradiated method should be further considered in addition to the radiobiological concepts for various brain tumors. (author)

  7. Poster - 51: A tumor motion-compensating system with tracking and prediction – a proof-of-concept study

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Kaiming; Teo, Peng; Kawalec, Philip; Pistorius, Stephen [CancerCare Manitoba (Canada)

    2016-08-15

    Purpose: This work reports on the development of a mechanical slider system for the counter-steering of tumor motion in adaptive Radiation Therapy (RT). The tumor motion was tracked using a weighted optical flow algorithm and its position is being predicted with a neural network (NN). Methods: The components of the proposed mechanical counter-steering system includes: (1) an actuator which provides the tumor motion, (2) the motion detection using an optical flow algorithm, (3) motion prediction using a neural network, (4) a control module and (5) a mechanical slider to counter-steer the anticipated motion of the tumor phantom. An asymmetrical cosine function and five patient traces (P1–P5) were used to evaluate the tracking of a 3D printed lung tumor. In the proposed mechanical counter-steering system, both actuator (Zaber NA14D60) and slider (Zaber A-BLQ0070-E01) were programed to move independently with LabVIEW and their positions were recorded by 2 potentiometers (ETI LCP12S-25). The accuracy of this counter-steering system is given by the difference between the two potentiometers. Results: The inherent accuracy of the system, measured using the cosine function, is −0.15 ± 0.06 mm. While the errors when tracking and prediction were included, is (0.04 ± 0.71) mm. Conclusion: A prototype tumor motion counter-steering system with tracking and prediction was implemented. The inherent errors are small in comparison to the tracking and prediction errors, which in turn are small in comparison to the magnitude of tumor motion. The results show that this system is suited for evaluating RT tracking and prediction.

  8. eTumorType, An Algorithm of Discriminating Cancer Types for Circulating Tumor Cells or Cell-free DNAs in Blood.

    Science.gov (United States)

    Zou, Jinfeng; Wang, Edwin

    2017-04-01

    With the technology development on detecting circulating tumor cells (CTCs) and cell-free DNAs (cfDNAs) in blood, serum, and plasma, non-invasive diagnosis of cancer becomes promising. A few studies reported good correlations between signals from tumor tissues and CTCs or cfDNAs, making it possible to detect cancers using CTCs and cfDNAs. However, the detection cannot tell which cancer types the person has. To meet these challenges, we developed an algorithm, eTumorType, to identify cancer types based on copy number variations (CNVs) of the cancer founding clone. eTumorType integrates cancer hallmark concepts and a few computational techniques such as stochastic gradient boosting, voting, centroid, and leading patterns. eTumorType has been trained and validated on a large dataset including 18 common cancer types and 5327 tumor samples. eTumorType produced high accuracies (0.86-0.96) and high recall rates (0.79-0.92) for predicting colon, brain, prostate, and kidney cancers. In addition, relatively high accuracies (0.78-0.92) and recall rates (0.58-0.95) have also been achieved for predicting ovarian, breast luminal, lung, endometrial, stomach, head and neck, leukemia, and skin cancers. These results suggest that eTumorType could be used for non-invasive diagnosis to determine cancer types based on CNVs of CTCs and cfDNAs. Copyright © 2017 Beijing Institute of Genomics, Chinese Academy of Sciences and Genetics Society of China. Production and hosting by Elsevier B.V. All rights reserved.

  9. Maintaining Aura's Orbit Requirements While Performing Orbit Maintenance Maneuvers Containing an Orbit Normal Delta-V Component

    Science.gov (United States)

    Johnson, Megan R.; Petersen, Jeremy D.

    2014-01-01

    The Earth Observing System (EOS) Afternoon Constellation consists of five member missions (GCOM-W1, Aqua, CALIPSO, CloudSat, and Aura), each of which maintain a frozen, sun-synchronous orbit with a 16-day repeating ground track that follows the Worldwide Reference System-2 (WRS-2). Under nominal science operations for Aura, the propulsion system is oriented such that the resultant thrust vector is aligned 13.493 degrees away from the velocity vector along the yaw axis. When performing orbit maintenance maneuvers, the spacecraft performs a yaw slew to align the thrust vector in the appropriate direction. A new Drag Make Up (DMU) maneuver operations scheme has been implemented for Aura alleviating the need for the 13.493 degree yaw slew. The focus of this investigation is to assess the impact that no-slew DMU maneuver operations will have on Aura's Mean Local Time (MLT) which drives the required along track separation between Aura and the constellation members, as well as Aura's frozen orbit properties, eccentricity and argument of perigee. Seven maneuver strategies were analyzed to determine the best operational approach. A mirror pole strategy, with maneuvers alternating at the North and South poles, was implemented operationally to minimize impact to the MLT. Additional analysis determined that the mirror pole strategy could be further modified to include frozen orbit maneuvers and thus maintain both MLT and the frozen orbit properties under noslew operations.

  10. Update on orbital reconstruction.

    Science.gov (United States)

    Chen, Chien-Tzung; Chen, Yu-Ray

    2010-08-01

    Orbital trauma is common and frequently complicated by ocular injuries. The recent literature on orbital fracture is analyzed with emphasis on epidemiological data assessment, surgical timing, method of approach and reconstruction materials. Computed tomographic (CT) scan has become a routine evaluation tool for orbital trauma, and mobile CT can be applied intraoperatively if necessary. Concomitant serious ocular injury should be carefully evaluated preoperatively. Patients presenting with nonresolving oculocardiac reflex, 'white-eyed' blowout fracture, or diplopia with a positive forced duction test and CT evidence of orbital tissue entrapment require early surgical repair. Otherwise, enophthalmos can be corrected by late surgery with a similar outcome to early surgery. The use of an endoscope-assisted approach for orbital reconstruction continues to grow, offering an alternative method. Advances in alloplastic materials have improved surgical outcome and shortened operating time. In this review of modern orbital reconstruction, several controversial issues such as surgical indication, surgical timing, method of approach and choice of reconstruction material are discussed. Preoperative fine-cut CT image and thorough ophthalmologic examination are key elements to determine surgical indications. The choice of surgical approach and reconstruction materials much depends on the surgeon's experience and the reconstruction area. Prefabricated alloplastic implants together with image software and stereolithographic models are significant advances that help to more accurately reconstruct the traumatized orbit. The recent evolution of orbit reconstruction improves functional and aesthetic results and minimizes surgical complications.

  11. Current concepts in non-gastrointestinal stromal tumor soft tissue sarcomas: A primer for radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Baheti, Akahay D. [Dept. of Radiology, Tata Memorial Centre, Mumbai (India); Tirumani, Harika [Dept. of Radiology, University of Arkansas for Medical Sciences, Little Rock (United States); O' Neill, Alibhe; Jagannathan, Jyothi P. [Dept. of Imaging, Dana-Farber Cancer Institute, Boston (United States)

    2017-01-15

    Non-gastrointestinal stromal tumor (GIST) soft tissue sarcomas (STSs) are a heterogeneous group of neoplasms whose classification and management continues to evolve with better understanding of their biologic behavior. The 2013 World Health Organization (WHO) has revised their classification based on new immunohistochemical and cytogenetic data. In this article, we will provide a brief overview of the revised WHO classification of soft tissue tumors, discuss in detail the radiology and management of the two most common adult non-GIST STS, namely liposarcoma and leiomyosarcoma, and review some of the emerging histology-driven targeted therapies in non-GIST STS, focusing on the role of the radiologist.

  12. Current concepts in non-gastrointestinal stromal tumor soft tissue sarcomas: A primer for radiologists

    International Nuclear Information System (INIS)

    Baheti, Akahay D.; Tirumani, Harika; O'Neill, Alibhe; Jagannathan, Jyothi P.

    2017-01-01

    Non-gastrointestinal stromal tumor (GIST) soft tissue sarcomas (STSs) are a heterogeneous group of neoplasms whose classification and management continues to evolve with better understanding of their biologic behavior. The 2013 World Health Organization (WHO) has revised their classification based on new immunohistochemical and cytogenetic data. In this article, we will provide a brief overview of the revised WHO classification of soft tissue tumors, discuss in detail the radiology and management of the two most common adult non-GIST STS, namely liposarcoma and leiomyosarcoma, and review some of the emerging histology-driven targeted therapies in non-GIST STS, focusing on the role of the radiologist

  13. Satellite laser ranging to low Earth orbiters: orbit and network validation

    Science.gov (United States)

    Arnold, Daniel; Montenbruck, Oliver; Hackel, Stefan; Sośnica, Krzysztof

    2018-04-01

    Satellite laser ranging (SLR) to low Earth orbiters (LEOs) provides optical distance measurements with mm-to-cm-level precision. SLR residuals, i.e., differences between measured and modeled ranges, serve as a common figure of merit for the quality assessment of orbits derived by radiometric tracking techniques. We discuss relevant processing standards for the modeling of SLR observations and highlight the importance of line-of-sight-dependent range corrections for the various types of laser retroreflector arrays. A 1-3 cm consistency of SLR observations and GPS-based precise orbits is demonstrated for a wide range of past and present LEO missions supported by the International Laser Ranging Service (ILRS). A parameter estimation approach is presented to investigate systematic orbit errors and it is shown that SLR validation of LEO satellites is not only able to detect radial but also along-track and cross-track offsets. SLR residual statistics clearly depend on the employed precise orbit determination technique (kinematic vs. reduced-dynamic, float vs. fixed ambiguities) but also reveal pronounced differences in the ILRS station performance. Using the residual-based parameter estimation approach, corrections to ILRS station coordinates, range biases, and timing offsets are derived. As a result, root-mean-square residuals of 5-10 mm have been achieved over a 1-year data arc in 2016 using observations from a subset of high-performance stations and ambiguity-fixed orbits of four LEO missions. As a final contribution, we demonstrate that SLR can not only validate single-satellite orbit solutions but also precise baseline solutions of formation flying missions such as GRACE, TanDEM-X, and Swarm.

  14. Orbital glass in HTSC

    International Nuclear Information System (INIS)

    Kusmartsev, F.V.

    1992-10-01

    The physical reasons why the orbital glass may exist in granular high-temperature superconductors and the existing experimental data appeared recently are discussed. The orbital glass is characterized by the coexistence of the orbital paramagnetic state with the superconducting state and occurs at small magnetic fields H c0 c1 . The transition in orbital glass arises at the critical field H c0 which is inversely proportional to the surface cross-area S of an average grain. In connection with theoretical predictions the possible experiments are proposed. (author). 10 refs

  15. The Mars Reconnaissance Orbiter Mission: 10 Years of Exploration from Mars Orbit

    Science.gov (United States)

    Johnston, M. Daniel; Zurek, Richard W.

    2016-01-01

    The Mars Reconnaissance Orbiter ( MRO ) entered Mars orbit on March 10, 2006. After five months of aerobraking, a series of propulsive maneuvers were used to establish the desired low -altitude science orbit. The spacecraft has been on station in its 255 x 320 k m, sun -synchronous (approximately 3 am -pm ), primary science orbit since September 2006 performing both scientific and Mars programmatic support functions. This paper will provide a summary of the major achievements of the mission to date and the major flight activities planned for the remainder of its third Extended Mission (EM3). Some of the major flight challenges the flight team has faced are also discussed.

  16. Orbital Infarction due to Sickle Cell Disease without Orbital Pain

    Directory of Open Access Journals (Sweden)

    Cameron L. McBride

    2016-01-01

    Full Text Available Sickle cell disease is a hemoglobinopathy that results in paroxysmal arteriolar occlusion and tissue infarction that can manifest in a plurality of tissues. Rarely, these infarcted crises manifest in the bony orbit. Orbital infarction usually presents with acute onset of periorbital tenderness, swelling, erythema, and pain. Soft tissue swelling can result in proptosis and attenuation of extraocular movements. Expedient diagnosis of sickle cell orbital infarction is crucial because this is a potentially sight-threatening entity. Diagnosis can be delayed since the presentation has physical and radiographic findings mimicking various infectious and traumatic processes. We describe a patient who presented with sickle cell orbital crisis without pain. This case highlights the importance of maintaining a high index of suspicion in patients with known sickle cell disease or of African descent born outside the United States in a region where screening for hemoglobinopathy is not routine, even when the presentation is not classic.

  17. Local orbit feedback

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Critically aligned experiments are sensitive to small changes in the electron beam orbit. At the NSLS storage rings, the electron beam and photon beam motions have been monitored over the past several years. In the survey conducted in 1986 by the NSLS Users Executive Committee, experimenters requested the vertical beam position variation and the vertical angle variation, within a given fill, remain within 10 μm and 10 μr, respectively. This requires improvement in the beam stability by about one order of magnitude. At the NSLS and SSRL storage rings, the beam that is originally centered on the position monitor by a dc orbit correction is observed to have two kinds of motion: a dc drift over a storage period of several hours and a beam bounce about its nominal position. These motions are a result of the equilibrium orbit not being held perfectly stable due to time-varying errors introduced into the magnetic guide field by power supplies, mechanical vibration of the magnets, cooling water temperature variations, etc. The approach to orbit stabilization includes (1) identifying and suppressing as many noise sources on the machine as possible, (2) correcting the beam position globally (see Section 6) by controlling a number of correctors around the circumference of the machine, and (3) correcting the beam position and angle at a given source location by position feedback using local detectors and local orbit bumps. The third approach, called Local Orbit Feedback will be discussed in this section

  18. Concept of Lunar Energy Park

    Science.gov (United States)

    Niino, Masayuki; Kisara, Katsuto; Chen, Lidong

    1993-10-01

    This paper presents a new concept of energy supply system named Lunar Energy Park (LEP) as one of the next-generation clean energy sources. In this concept, electricity is generated by nuclear power plants built on the moon and then transmitted to receiving stations on the earth by laser beam through transporting systems situated in geostationary orbit. The lunar nuclear power plants use a high-efficiency composite energy conversion system consisting of thermionic and thermoelectric generators to change nuclear thermal energy into electricity directly. The nuclear resources are considered to be available from the moon, and nuclear fuel transport from earth to moon is not necessary. Because direct energy conversion systems are employed, the lunar nuclear plants can be operated and controlled by robots and are maintenance-free, and so will cause no pollution to humans. The key technologies for LEP include improvements of conversion efficiency of both thermionic and thermoelectric converters, and developments of laser-beam power transmission technology as well. The details, including the construction of lunar nuclear plants, energy conversion and energy transmission systems, as well as the research plan strategies for this concept are reviewed.

  19. Comparison of angiographic, gammagraphic, and histological data in orbital tumours: concerning 13 observations

    International Nuclear Information System (INIS)

    Emery, M.T.

    1976-01-01

    The aim of this work is to compare the value of gammagraphic and angiographic examinations in intra-orbital expansive processes and to hole for a histological explanation when the two examinations disagree. All the gammagraphs used were obtained with technetium 99m-labelled ferrous ascorbate. Orbital gammagraphy requires a radioelement combining the advantages of easily detectable radioactivity and fast elimination from healthy tissues while keeping a strong tumoral uptake. Sup(99m)Tc-labelled ferrous ascorbate fulfils these conditions. Technetium 99m, perfectly safe because of its short half-life and low radiation energy, allows the scintigraphic detection of expansive processes. By its association with ferrous ascorbate, which has a very high kidney and plasma clearance rate, the vascular background is reduced considerably and the relative radiotracer concentration in the diseased area increased (the background is due to fixation of the radioelement in the facial and orbital muscles, the mucous membranes of the nose and sinus and the vein sinuses at the base of the skull). The complex used in this study is obtained from 40mg ferrous ascorbate to which are added 1ml Thris buffer at pH 7.85 and 5ml 99mTc pertechnetate solution. 10 to 15 microcuries are injected intraveinously or absorbed parenterally [fr

  20. Osteosarcoma of the spheno-temporo-orbital bone: Imaging aspects of such unusual location

    Directory of Open Access Journals (Sweden)

    ABDEL ILAH RAYAN ALAOUI BOUARRAQUI

    2018-05-01

    Full Text Available Osteosarcoma of the spheno-temporo-orbital bone is a very rare tumor. Despite the fact that primary osteogenic sarcomas are the most common bone neoplasm, their location in the skull bone is uncommon representing less than 2% of all skull tumors. We report the case of a 41-year-old woman, who has experienced periorbital pain with exophthalmos and left eye vision loss. Neuroimaging analysis including both brain computed tomography (CT-scan and Magnetic resonance imaging (MRI were performed. Although radiographic features of skull bone osteosarcomas are not specific, the combination of several radiographic features could lead to this diagnosis in such rare location. The final diagnosis was established by a trans-temporal biopsy with immunohistochemical study. Neurosurgical resection of the primary tumor was not possible given the important extent of the tumor and the involvement of adjacent structures, so the patient underwent conformational radiotherapy. The evolution was marked by local and metastatic progression. The patient received palliative chemotherapy and died few months later. The purpose of presenting this case is not only to report an uncommon malignancy of the skull bone, but also to provide imaging aspects of this rare location and to raise awareness among radiologists in order to consider this radiological entity as a differential diagnosis when a skull bone process is identified.

  1. Validation of Galileo orbits using SLR with a focus on satellites launched into incorrect orbital planes

    Science.gov (United States)

    Sośnica, Krzysztof; Prange, Lars; Kaźmierski, Kamil; Bury, Grzegorz; Drożdżewski, Mateusz; Zajdel, Radosław; Hadas, Tomasz

    2018-02-01

    The space segment of the European Global Navigation Satellite System (GNSS) Galileo consists of In-Orbit Validation (IOV) and Full Operational Capability (FOC) spacecraft. The first pair of FOC satellites was launched into an incorrect, highly eccentric orbital plane with a lower than nominal inclination angle. All Galileo satellites are equipped with satellite laser ranging (SLR) retroreflectors which allow, for example, for the assessment of the orbit quality or for the SLR-GNSS co-location in space. The number of SLR observations to Galileo satellites has been continuously increasing thanks to a series of intensive campaigns devoted to SLR tracking of GNSS satellites initiated by the International Laser Ranging Service. This paper assesses systematic effects and quality of Galileo orbits using SLR data with a main focus on Galileo satellites launched into incorrect orbits. We compare the SLR observations with respect to microwave-based Galileo orbits generated by the Center for Orbit Determination in Europe (CODE) in the framework of the International GNSS Service Multi-GNSS Experiment for the period 2014.0-2016.5. We analyze the SLR signature effect, which is characterized by the dependency of SLR residuals with respect to various incidence angles of laser beams for stations equipped with single-photon and multi-photon detectors. Surprisingly, the CODE orbit quality of satellites in the incorrect orbital planes is not worse than that of nominal FOC and IOV orbits. The RMS of SLR residuals is even lower by 5.0 and 1.5 mm for satellites in the incorrect orbital planes than for FOC and IOV satellites, respectively. The mean SLR offsets equal -44.9, -35.0, and -22.4 mm for IOV, FOC, and satellites in the incorrect orbital plane. Finally, we found that the empirical orbit models, which were originally designed for precise orbit determination of GNSS satellites in circular orbits, provide fully appropriate results also for highly eccentric orbits with variable linear

  2. Oligo-branched peptides for tumor targeting: from magic bullets to magic forks.

    Science.gov (United States)

    Falciani, Chiara; Pini, Alessandro; Bracci, Luisa

    2009-02-01

    Selective targeting of tumor cells is the final goal of research and drug discovery for cancer diagnosis, imaging and therapy. After the invention of hybridoma technology, the concept of magic bullet was introduced into the field of oncology, referring to selective killing of tumor cells, by specific antibodies. More recently, small molecules and peptides have also been proposed as selective targeting agents. We analyze the state of the art of tumor-selective agents that are presently available and tested in clinical settings. A novel approach based on 'armed' oligo-branched peptides as tumor targeting agents, is discussed and compared with existing tumor-selective therapies mediated by antibodies, small molecules or monomeric peptides. Oligo-branched peptides could be novel drugs that combine the advantages of antibodies and small molecules.

  3. Orbital preservation in a maxillectomy

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Katsuhiko; Nishikawa, Hitomi; Kumagai, Masahiko; Dosaka, Yoshihiro; Kuroda, Toru; Atago, Yoshihiro; Nishio, Masamichi [Sapporo National Hospital (Japan)

    1999-07-01

    In the past 9 years, 38 patients of the maxillary cancer were treated by a combination of radiation and surgery. Sixteen patients showed the orbital involvement as confirmed by a CT scan and/or MRI. An orbital excenteration was necessary in 6 patients, due mainly to deep intraorbital invasion, while in 10, the orbital contents were preserved despite the involvement of the orbital capsule. The local rate of the orbital region in the latter patients evaluated at 48 months after the initial surgery was 44%. For the treatment of the recurrence at the orbital capsule. The application of gold grain (Au{sup 198}) thus appeared to be a useful tool for further preserving the eye. (author)

  4. Orbital preservation in a maxillectomy

    International Nuclear Information System (INIS)

    Tanaka, Katsuhiko; Nishikawa, Hitomi; Kumagai, Masahiko; Dosaka, Yoshihiro; Kuroda, Toru; Atago, Yoshihiro; Nishio, Masamichi

    1999-01-01

    In the past 9 years, 38 patients of the maxillary cancer were treated by a combination of radiation and surgery. Sixteen patients showed the orbital involvement as confirmed by a CT scan and/or MRI. An orbital excenteration was necessary in 6 patients, due mainly to deep intraorbital invasion, while in 10, the orbital contents were preserved despite the involvement of the orbital capsule. The local rate of the orbital region in the latter patients evaluated at 48 months after the initial surgery was 44%. For the treatment of the recurrence at the orbital capsule. The application of gold grain (Au 198 ) thus appeared to be a useful tool for further preserving the eye. (author)

  5. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  6. Introducing Earth's Orbital Eccentricity

    Science.gov (United States)

    Oostra, Benjamin

    2015-01-01

    Most students know that planetary orbits, including Earth's, are elliptical; that is Kepler's first law, and it is found in many science textbooks. But quite a few are mistaken about the details, thinking that the orbit is very eccentric, or that this effect is somehow responsible for the seasons. In fact, the Earth's orbital eccentricity is…

  7. Diagnostic radiation and its prognosis of pineal region tumor

    International Nuclear Information System (INIS)

    Momose, Toshimitsu; Aoki, Yukimasa; Akanuma, Atsuo; Machida, Tohru; Iio, Masahiro; Takakura, Kimitomo

    1984-01-01

    20 Gy of local irradiation was performed for the patients with pineal region tumor. We evaluated the tumor volume on X-CT in the pre-radiation and 20 Gy of post-radiation state. If tumor is sensitive enough to radiation therapy, we add 40 Gy of whole brain and 30 to 40 Gy of whole spine irradiation. If not, we transfer patients to neurosurgeons for the purpose of tumor ressection. We call this procedure ''Diagnostic Radiation.'' We proposed the concept of TRR (Tumor Regression Ratio) in order to evaluate our protocol more objctively. TRR is as follows: TRR (%) = [1-Total Tumor Volume (at each dose) / Total Tumor Volume (at o Gy)] x 100 (%) Total Tumor Volume(mm 3 ) = slice thickness(mm) x siguma HDA (mm 2 ) on each slice: where HDA is high density area on enhanced CT. Eleven patients were studied and TRR of each patients was calculated. The relations between TRR, tumor markers, CSF seeding and prognoiss was discussed. From our study, (1) TRR at 20Gy was important and might predict approximate prognosis of each cae case. A) TRR = 100 → very good B) TRR < 20 → poor C) 20 <= TRR < 100 → high possibility (2) Majority of TRR < 100 cases have turned out to be histologically in teratoma category. (3) Good correlation between the level of tumor markers and prognosis was observed. Cases with elevated level of AFP and/or HCG were radio- resistant and had poor prognosis. (4) Distant metastasis must also be kept in mind in the treatment of pineal region tumor. (author)

  8. Guidance and Navigation for Rendezvous and Proximity Operations with a Non-Cooperative Spacecraft at Geosynchronous Orbit

    Science.gov (United States)

    Barbee, Brent William; Carpenter, J. Russell; Heatwole, Scott; Markley, F. Landis; Moreau, Michael; Naasz, Bo J.; VanEepoel, John

    2010-01-01

    The feasibility and benefits of various spacecraft servicing concepts are currently being assessed, and all require that the servicer spacecraft perform rendezvous, proximity, and capture operations with the target spacecraft to be serviced. Many high-value spacecraft, which would be logical targets for servicing from an economic point of view, are located in geosynchronous orbit, a regime in which autonomous rendezvous and capture operations are not commonplace. Furthermore, existing GEO spacecraft were not designed to be serviced. Most do not have cooperative relative navigation sensors or docking features, and some servicing applications, such as de-orbiting of a non-functional spacecraft, entail rendezvous and capture with a spacecraft that may be non-functional or un-controlled. Several of these challenges have been explored via the design of a notional mission in which a nonfunctional satellite in geosynchronous orbit is captured by a servicer spacecraft and boosted into super-synchronous orbit for safe disposal. A strategy for autonomous rendezvous, proximity operations, and capture is developed, and the Orbit Determination Toolbox (ODTBX) is used to perform a relative navigation simulation to assess the feasibility of performing the rendezvous using a combination of angles-only and range measurements. Additionally, a method for designing efficient orbital rendezvous sequences for multiple target spacecraft is utilized to examine the capabilities of a servicer spacecraft to service multiple targets during the course of a single mission.

  9. The Coupled Orbit-Attitude Dynamics and Control of Electric Sail in Displaced Solar Orbits

    Directory of Open Access Journals (Sweden)

    Mingying Huo

    2017-01-01

    Full Text Available Displaced solar orbits for spacecraft propelled by electric sails are investigated. Since the propulsive thrust is induced by the sail attitude, the orbital and attitude dynamics of electric-sail-based spacecraft are coupled and required to be investigated together. However, the coupled dynamics and control of electric sails have not been discussed in most published literatures. In this paper, the equilibrium point of the coupled dynamical system in displaced orbit is obtained, and its stability is analyzed through a linearization. The results of stability analysis show that only some of the orbits are marginally stable. For unstable displaced orbits, linear quadratic regulator is employed to control the coupled attitude-orbit system. Numerical simulations show that the proposed strategy can control the coupled system and a small torque can stabilize both the attitude and orbit. In order to generate the control force and torque, the voltage distribution problem is studied in an optimal framework. The numerical results show that the control force and torque of electric sail can be realized by adjusting the voltage distribution of charged tethers.

  10. Application of orbital strong magnet in the extraction of deep orbital magnetic foreign bodies

    Directory of Open Access Journals (Sweden)

    Jin-Chen Jia

    2017-12-01

    Full Text Available AIM: To investigate the surgical method and efficacy of extraction of deep orbital magnetic foreign bodies by mean of an orbital strong magnet. METHODS: A retrospective analysis of clinical data of patients with deep orbital magnetic foreign bodies(OMFBin Hebei Eye Hospital from June 2014 to May 2017 was processed. A total of 23 eyes were enrolled, among them, 14 eyes of extraorbital OMFB, 9 eyes of intraorbital OMFB. The rate of extraction of foreign bodies and the postoperative complications were observed. RESULTS: All eyes of intraorbital foreign bodies were successfully extracted with 100% success rate. Twelve of 14 eyes of extraorbital foreign bodies were extracted with 86% success rate. Mild orbital hemorrhage were found in 2 eyes. There was no other obvious complication such as visual loss, orbital massive hemorrhage or limited ocular movement. CONCLUSION: It's an ideal surgical method to extract the deep orbital magnetic foreign bodies by mean of an orbital strong magnet, with mini-injury, high success rate, short duration and few complications.

  11. How many molecular subtypes? Implications of the unique tumor principle in personalized medicine.

    Science.gov (United States)

    Ogino, Shuji; Fuchs, Charles S; Giovannucci, Edward

    2012-07-01

    Cancers are complex multifactorial diseases. For centuries, conventional organ-based classification system (i.e., breast cancer, lung cancer, colon cancer, colorectal cancer, prostate cancer, lymphoma, leukemia, and so on) has been utilized. Recently, molecular diagnostics has become an essential component in clinical decision-making. However, tumor evolution and behavior cannot accurately be predicted, despite numerous research studies reporting promising tumor biomarkers. To advance molecular diagnostics, a better understanding of intratumor and intertumor heterogeneity is essential. Tumor cells interact with the extracellular matrix and host non-neoplastic cells in the tumor microenvironment, which is influenced by genomic variation, hormones, and dietary, lifestyle and environmental exposures, implicated by molecular pathological epidemiology. Essentially, each tumor possesses its own unique characteristics in terms of molecular make-up, tumor microenvironment and interactomes within and between neoplastic and host cells. Starting from the unique tumor concept and paradigm, we can better classify tumors by molecular methods, and move closer toward personalized cancer medicine and prevention.

  12. Congenital orbital teratoma.

    Science.gov (United States)

    Aiyub, Shereen; Chan, Wengonn; Szetu, John; Sullivan, Laurence J; Pater, John; Cooper, Peter; Selva, Dinesh

    2013-12-01

    We present a case of mature congenital orbital teratoma managed with lid-sparing exenteration and dermis fat graft. This is a case report on the management of congenital orbital teratoma. A full-term baby was born in Fiji with prolapsed right globe which was surrounded by a nonpulsatile, cystic mass. Clinical and imaging features were consistent with congenital orbital teratoma. Due to limited surgical expertise, the patient was transferred to Adelaide, Australia for further management. The patient underwent a lid-sparing exenteration with frozen section control of the apical margin. A dermis fat graft from the groin was placed beneath the lid skin to provide volume. Histopathology revealed mature tissues from each of the three germ cell layers which confirmed the diagnosis of mature teratoma. We describe the successful use of demis fat graft in socket reconstruction following lid-sparing exenteration for congenital orbital teratoma.

  13. Congenital orbital teratoma

    Directory of Open Access Journals (Sweden)

    Shereen Aiyub

    2013-01-01

    Full Text Available We present a case of mature congenital orbital teratoma managed with lid-sparing exenteration and dermis fat graft. This is a case report on the management of congenital orbital teratoma. A full-term baby was born in Fiji with prolapsed right globe which was surrounded by a nonpulsatile, cystic mass. Clinical and imaging features were consistent with congenital orbital teratoma. Due to limited surgical expertise, the patient was transferred to Adelaide, Australia for further management. The patient underwent a lid-sparing exenteration with frozen section control of the apical margin. A dermis fat graft from the groin was placed beneath the lid skin to provide volume. Histopathology revealed mature tissues from each of the three germ cell layers which confirmed the diagnosis of mature teratoma. We describe the successful use of demis fat graft in socket reconstruction following lid-sparing exenteration for congenital orbital teratoma.

  14. Limited utility of tissue micro-arrays in detecting intra-tumoral heterogeneity in stem cell characteristics and tumor progression markers in breast cancer.

    Science.gov (United States)

    Kündig, Pascale; Giesen, Charlotte; Jackson, Hartland; Bodenmiller, Bernd; Papassotirolopus, Bärbel; Freiberger, Sandra Nicole; Aquino, Catharine; Opitz, Lennart; Varga, Zsuzsanna

    2018-05-08

    Intra-tumoral heterogeneity has been recently addressed in different types of cancer, including breast cancer. A concept describing the origin of intra-tumoral heterogeneity is the cancer stem-cell hypothesis, proposing the existence of cancer stem cells that can self-renew limitlessly and therefore lead to tumor progression. Clonal evolution in accumulated single cell genomic alterations is a further possible explanation in carcinogenesis. In this study, we addressed the question whether intra-tumoral heterogeneity can be reliably detected in tissue-micro-arrays in breast cancer by comparing expression levels of conventional predictive/prognostic tumor markers, tumor progression markers and stem cell markers between central and peripheral tumor areas. We analyzed immunohistochemical expression and/or gene amplification status of conventional prognostic tumor markers (ER, PR, HER2, CK5/6), tumor progression markers (PTEN, PIK3CA, p53, Ki-67) and stem cell markers (mTOR, SOX2, SOX9, SOX10, SLUG, CD44, CD24, TWIST) in 372 tissue-micro-array samples from 72 breast cancer patients. Expression levels were compared between central and peripheral tumor tissue areas and were correlated to histopathological grading. 15 selected cases additionally underwent RNA sequencing for transcriptome analysis. No significant difference in any of the analyzed between central and peripheral tumor areas was seen with any of the analyzed methods/or results that showed difference. Except mTOR, PIK3CA and SOX9 (nuclear) protein expression, all markers correlated significantly (p < 0.05) with histopathological grading both in central and peripheral areas. Our results suggest that intra-tumoral heterogeneity of stem-cell and tumor-progression markers cannot be reliably addressed in tissue-micro-array samples in breast cancer. However, most markers correlated strongly with histopathological grading confirming prognostic information as expression profiles were independent on the site of the

  15. Orbit Determination of Spacecraft in Earth-Moon L1 and L2 Libration Point Orbits

    Science.gov (United States)

    Woodard, Mark; Cosgrove, Daniel; Morinelli, Patrick; Marchese, Jeff; Owens, Brandon; Folta, David

    2011-01-01

    The ARTEMIS mission, part of the THEMIS extended mission, is the first to fly spacecraft in the Earth-Moon Lissajous regions. In 2009, two of the five THEMIS spacecraft were redeployed from Earth-centered orbits to arrive in Earth-Moon Lissajous orbits in late 2010. Starting in August 2010, the ARTEMIS P1 spacecraft executed numerous stationkeeping maneuvers, initially maintaining a lunar L2 Lissajous orbit before transitioning into a lunar L1 orbit. The ARTEMIS P2 spacecraft entered a L1 Lissajous orbit in October 2010. In April 2011, both ARTEMIS spacecraft will suspend Lissajous stationkeeping and will be maneuvered into lunar orbits. The success of the ARTEMIS mission has allowed the science team to gather unprecedented magnetospheric measurements in the lunar Lissajous regions. In order to effectively perform lunar Lissajous stationkeeping maneuvers, the ARTEMIS operations team has provided orbit determination solutions with typical accuracies on the order of 0.1 km in position and 0.1 cm/s in velocity. The ARTEMIS team utilizes the Goddard Trajectory Determination System (GTDS), using a batch least squares method, to process range and Doppler tracking measurements from the NASA Deep Space Network (DSN), Berkeley Ground Station (BGS), Merritt Island (MILA) station, and United Space Network (USN). The team has also investigated processing of the same tracking data measurements using the Orbit Determination Tool Kit (ODTK) software, which uses an extended Kalman filter and recursive smoother to estimate the orbit. The orbit determination results from each of these methods will be presented and we will discuss the advantages and disadvantages associated with using each method in the lunar Lissajous regions. Orbit determination accuracy is dependent on both the quality and quantity of tracking measurements, fidelity of the orbit force models, and the estimation techniques used. Prior to Lissajous operations, the team determined the appropriate quantity of tracking

  16. Expression of Vascular Endothelial Growth Factor Receptors in Benign Vascular Lesions of the Orbit: A Case Series.

    Science.gov (United States)

    Atchison, Elizabeth A; Garrity, James A; Castillo, Francisco; Engman, Steven J; Couch, Steven M; Salomão, Diva R

    2016-01-01

    Vascular lesions of the orbit, although not malignant, can cause morbidity because of their location near critical structures in the orbit. For the same reason, they can be challenging to remove surgically. Anti-vascular endothelial growth factor (VEGF) drugs are increasingly being used to treat diseases with prominent angiogenesis. Our study aimed to determine to what extent VEGF receptors and their subtypes are expressed on selected vascular lesions of the orbit. Retrospective case series of all orbital vascular lesions removed by one of the authors (JAG) at the Mayo Clinic. A total of 52 patients who underwent removal of vascular orbital lesions. The pathology specimens from the patients were retrieved, their pathologic diagnosis was confirmed, demographic and clinical information were gathered, and sections from vascular tumors were stained with vascular endothelial growth factor receptor (VEGFR), vascular endothelial growth factor receptor type 1 (VEGFR1), vascular endothelial growth factor receptor type 2 (VEGFR2), and vascular endothelial growth factor receptor type 3 (VEGFR3). The existence and pattern of staining with VEGF and its subtypes on these lesions. There were 28 specimens of venous malformations, 4 capillary hemangiomas, 7 lymphatic malformations, and 6 lymphaticovenous malformations. All samples stained with VEGF, 55% stained with VEGFR1, 98% stained with VEGFR2, and 96% stained with VEGFR3. Most (94%) of the VEGFR2 staining was diffuse. Most orbital vascular lesions express VEGF receptors, which may suggest a future target for nonsurgical treatment. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. Macromolecular contrast media. A new approach for characterising breast tumors with MR-mammography

    International Nuclear Information System (INIS)

    Daldrup, H.E.; Gossmann, A.; Koeln Univ.; Wendland, M.; Brasch, R.C.; Rosenau, W.

    1997-01-01

    The value of macromolecular contrast agents (MMCM) for the characterization of benign and malignant breast tumors will be demonstrated in this review. Animal studies suggest a high potential of MMCM to increase the specificity of MR-mammography. The concept of tumor differentiation is based on the pathological hyperpermeability of microvessels in malignant tumors. MMCM show a leak into the interstitium of carcinomas, whereas they are confined to the intravascular space in benign tumors. Capabilities and limitations of the MMCM-prototype. Albumin-Gd-DTPA, for breast tumor characterization will be summarized and compared to the standard low molecular weight contrast agent Gd-DTPA. Initial experience with new MMCM, such as Dendrimers, Gd-DTPA-Polylysine and MS-325 will be outlined. The potential of 'blood-pool'-iron oxides, such as AMI-227 for the evaluation of tumor microvascular permeabilities will be discussed. (orig.) [de

  18. Recent developments and current concepts in medulloblastoma.

    Science.gov (United States)

    Gerber, N U; Mynarek, M; von Hoff, K; Friedrich, C; Resch, A; Rutkowski, S

    2014-04-01

    Medulloblastoma is the most common malignant brain tumor of childhood. While prognosis has significantly improved in the last decades with multimodal therapy including surgery, radiotherapy, and chemotherapy, one third of patients still succumb to their disease. Further research is needed to find more efficient treatment strategies for prognostically unfavorable patient groups and to minimize long-term sequelae of tumor treatment. This review gives a summary of the current state of treatment concepts including an outlook on the near future. We describe recent advances in the understanding of molecular mechanisms, their potential impact on risk stratification in upcoming clinical trials, and perspectives for the clinical implementation of targeted therapies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Advances in Cancer Immunotherapy in Solid Tumors

    Directory of Open Access Journals (Sweden)

    Smitha Menon

    2016-11-01

    Full Text Available Immunotherapy is heralded as one of the most important advances in oncology. Until recently, only limited immunotherapeutic options were available in selected immunogenic cancers like melanoma and renal cell carcinomas. Nowadays, there is an improved understanding that anti-tumor immunity is controlled by a delicate balance in the tumor microenvironment between immune stimulatory and immune inhibitory pathways. Either by blocking the inhibitory pathways or stimulating the activating pathways that regulate cytotoxic lymphocytes, anti-tumor immunity can be enhanced leading to durable anti-tumor responses. Drugs which block the immune regulatory checkpoints namely the PD-1/PDL1 and CTLA 4 pathway have shown tremendous promise in a wide spectrum of solid and hematological malignancies, significantly improving overall survival in newly diagnosed and heavily pretreated patients alike. Hence there is renewed enthusiasm in the field of immune oncology with current research focused on augmenting responses to checkpoint inhibitors by combination therapy as well as studies looking at other immune modulators and adoptive T cell therapy. In this article, we highlight the key clinical advances and concepts in immunotherapy with particular emphasis on checkpoint inhibition as well as the future direction in this field.

  20. Radiology of orbital trauma

    International Nuclear Information System (INIS)

    Kelly, J.K.; Lazo, A.; Metes, J.J.

    1988-01-01

    Computed tomography has become the gold standard against which to measure orbital imaging modalities. The simultaneous display of bone, soft tissues, paranasal sinuses, and intracranial structures is a unique advantage. Radiation dose and cost have been cited as disadvantages. These would suggest that CT be reserved for the patient with significant orbital injury or difficult diagnostic problems. Magnetic resonance is limited in the investigation of orbital trauma

  1. Overview of Small and Large-Scale Space Solar Power Concepts

    Science.gov (United States)

    Potter, Seth; Henley, Mark; Howell, Joe; Carrington, Connie; Fikes, John

    2006-01-01

    An overview of space solar power studies performed at the Boeing Company under contract with NASA will be presented. The major concepts to be presented are: 1. Power Plug in Orbit: this is a spacecraft that collects solar energy and distributes it to users in space using directed radio frequency or optical energy. Our concept uses solar arrays having the same dimensions as ISS arrays, but are assumed to be more efficient. If radiofrequency wavelengths are used, it will necessitate that the receiving satellite be equipped with a rectifying antenna (rectenna). For optical wavelengths, the solar arrays on the receiving satellite will collect the power. 2. Mars Clipper I Power Explorer: this is a solar electric Mars transfer vehicle to support human missions. A near-term precursor could be a high-power radar mapping spacecraft with self-transport capability. Advanced solar electric power systems and electric propulsion technology constitute viable elements for conducting human Mars missions that are roughly comparable in performance to similar missions utilizing alternative high thrust systems, with the one exception being their inability to achieve short Earth-Mars trip times. 3. Alternative Architectures: this task involves investigating alternatives to the traditional solar power satellite (SPS) to supply commercial power from space for use on Earth. Four concepts were studied: two using photovoltaic power generation, and two using solar dynamic power generation, with microwave and laser power transmission alternatives considered for each. All four architectures use geostationary orbit. 4. Cryogenic Propellant Depot in Earth Orbit: this concept uses large solar arrays (producing perhaps 600 kW) to electrolyze water launched from Earth, liquefy the resulting hydrogen and oxygen gases, and store them until needed by spacecraft. 5. Beam-Powered Lunar Polar Rover: a lunar rover powered by a microwave or laser beam can explore permanently shadowed craters near the lunar

  2. POwer WithOut Wire (POWOW): A SEP Concept for Space Exploration

    Science.gov (United States)

    Brandhorst, Henry W., Jr.; ONeill, Mark

    2000-01-01

    Electric propulsion has emerged as a cost-effective solution to a wide range of satellite applications. Deep Space 1 demonstrated electric propulsion as a primary propulsion source for a spacecraft. The POwer WithOut Wires (POWOW) concept has been developed as a solar electric propelled spacecraft that would travel to Mars, for example, enter selenosynchronous orbit and then use lasers to beam power to surface installations. This concept has been developed with industrial expertise in high efficiency solar cells, advanced concentrator modules, innovative arrays, and high power electric propulsion systems. The paper will present the latest version of the spacecraft, the technologies involved, possible missions and trip times to Mars and laser beaming options. The POWOW spacecraft is a general purpose solar electric propulsion system that includes technologies that are directly applicable to commercial and government spacecraft with power levels ranging from 4 kW in Low Earth Orbits (LEO) to about 1 MW. The system is modular and expandable. Learning curve costing methodologies are used to demonstrate cost effectiveness of a modular system.

  3. Chemotherapy synergizes with radioimmunotherapy targeting La autoantigen in tumors.

    Directory of Open Access Journals (Sweden)

    Fares Al-Ejeh

    Full Text Available To date, inefficient delivery of therapeutic doses of radionuclides to solid tumors limits the clinical utility of radioimmunotherapy. We aim to test the therapeutic utility of Yttrium-90 ((90Y-radio-conjugates of a monoclonal antibody, which we showed previously to bind specifically to the abundant intracellular La ribonucleoprotein revealed in dead tumor cells after DNA-damaging treatment.Immunoconjugates of the DAB4 clone of the La-specific monoclonal antibody, APOMAB, were prepared using the metal chelator, 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA, and then radiolabeled with (90Y. Mice bearing established subcutaneous tumors were treated with (90Y-DOTA-DAB4 alone or after chemotherapy. Non-radiosensitizing cyclophosphamide/etoposide chemotherapy was used for the syngeneic EL4 lymphoma model. Radiosensitizing cisplatin/gemcitabine chemotherapy was used for the syngeneic Lewis Lung carcinoma (LL2 model, and for the xenograft models of LNCaP prostatic carcinoma and Panc-1 pancreatic carcinoma. We demonstrate the safety, specificity, and efficacy of (90Y-DOTA-DAB4-radioimmunotherapy alone or combined with chemotherapy. EL4 lymphoma-bearing mice either were cured at higher doses of radioimmunotherapy alone or lower doses of radioimmunotherapy in synergy with chemotherapy. Radioimmunotherapy alone was less effective in chemo- and radio-resistant carcinoma models. However, radioimmunotherapy synergized with radiosensitizing chemotherapy to retard significantly tumor regrowth and so prolong the survival of mice bearing LL2, LNCaP, or Panc-1 subcutaneous tumor implants.We report proof-of-concept data supporting a unique form of radioimmunotherapy, which delivers bystander killing to viable cancer cells after targeting the universal cancer antigen, La, created by DNA-damaging treatment in neighboring dead cancer cells. Subsequently we propose that DAB4-targeted ionizing radiation induces additional cycles of tumor cell death

  4. Molecular orbital study of the chemisorption of carbon monoxide on a tungsten (100) surface

    International Nuclear Information System (INIS)

    Lee, T.H.; Rabalais, J.W.

    1978-01-01

    The adsorption energies of carbon monoxide chemisorbed at various sites on a tungsten (100) surface have been calculated by extended Hueckel molecular orbital theory (EHMO). The concept of a 'surface molecule' in which CO is bonded to an array of tungsten atoms Wsub(n) has been employed. Dissociative adsorption in which C occupies a four-fold, five-coordination site and O occupies either a four- or two-fold site has been found to be the most stable form for CO on a W surface. Stable one-fold and two-fold sites of molecularly adsorbed CO have also been found in which the CO group is normal to the surface plane and the C atom is nearest the surface. Adsorption energies and molecular orbitals for the stable molecularly and dissociatively adsorbed CO sites are compared with the experimental data on various types of adsorbed CO, i.e. virgin-, α-, and β-CO. Models are suggested for each of these adsorption types. The strongest bonding interactions occur between the CO 5sigma orbital and the totally symmetric 5d and 6s orbitals of the Wsub(n) cluster. Possible mechanisms for conversion of molecularly adsorbed CO to dissociatively adsorbed CO are proposed and the corresponding activation energies are estimated. (Auth.)

  5. Manipulation and application of orbital ordering

    International Nuclear Information System (INIS)

    Sheng Zhigao; Sun Yuping

    2014-01-01

    Under certain conditions, the orbits of the outmost shell electrons in strong correlated materials can be localized in order, which gives birth to so-called orbital ordering. During the construction or destruction of the orbital ordering, strongly correlated materials show fruitful quantum critical phenomena with great potential for future applications. We first present the mechanism for the construction of orbital ordering. Then, some physical properties associated with orbits are discussed. Finally, we emphasize the key points and progress in the research of orbital ordering controlling. (authors)

  6. Failure analysis of satellite subsystems to define suitable de-orbit devices

    Science.gov (United States)

    Palla, Chiara; Peroni, Moreno; Kingston, Jennifer

    2016-11-01

    activation procedure for a de-orbit strategy and the level of integration it should have with the host satellite in order to be activated before a total failure. At Cranfield Space Research Centre two different solutions have already been developed as de-orbit sail payloads for microsatellites (Icarus-1 on TechDemoSat-1 and Icarus-3 on Carbonite-1 currently on-orbit, DOM for future ESA ESEO mission). This study will provide a useful input to improve and refine the current de-orbit concepts for future satellite missions.

  7. Pictorial essay: Orbital tuberculosis

    International Nuclear Information System (INIS)

    Narula, Mahender K; Chaudhary, Vikas; Baruah, Dhiraj; Kathuria, Manoj; Anand, Rama

    2010-01-01

    Tuberculosis of the orbit is rare, even in places where tuberculosis is endemic. The disease may involve soft tissue, the lacrimal gland, or the periosteum or bones of the orbital wall. Intracranial extension, in the form of extradural abscess, and infratemporal fossa extension has been described. This pictorial essay illustrates the imaging findings of nine histopathologically confirmed cases of orbital tuberculosis. All these patients responded to antituberculous treatment

  8. Orbit and optics distortion in fixed field alternating gradient muon accelerators

    Directory of Open Access Journals (Sweden)

    Shinji Machida

    2007-11-01

    Full Text Available In a linear nonscaling fixed field alternating gradient (FFAG accelerator, betatron tunes vary over a wide range and a beam has to cross integer and half-integer tunes several times. Although it is plausible to say that integer and half-integer resonances are not harmful if the crossing speed is fast, no quantitative argument exists. With tracking simulation, we studied orbit and optics distortion due to alignment and magnet errors. It was found that the concept of integer and half-integer resonance crossing is irrelevant to explain beam behavior in a nonscaling FFAG when acceleration is fast and betatron tunes change quickly. In a muon FFAG accelerator, it takes 17 turns for acceleration and the betatron tunes change more than 10, for example. Instead, the orbit and optics distortion is excited by random dipole and quadrupole kicks. The latter causes beam size growth because the beam starts tumbling in phase space, but not necessarily with emittance growth.

  9. Current concepts for chronochemotherapy of cancer.

    Science.gov (United States)

    Laerum, O D; Smaaland, R; Abrahamsen, J F

    1995-01-01

    In this article, a survey on the concepts and scientific basis for applying chemotherapy against malignant tumors on a circadian schedule is given. The idea is to give the cytostatic drugs at times of the day when optimal effect on the tumor is achieved, but at the same time causing minimal toxic side effects. Following a brief description of the complexity of cancer tissue, some aspects of the present status of cancer chemotherapy in general are reviewed. Applications of chronobiology in cancer treatment are then surveyed together with possibilities to increase cytostatic doses and reduce side effects. When optimal tumor cell kill is achieved, the next step is to address the circadian aspects of normal organs, including the proliferative behavior of tissues with rapid cell renewal. Finally, the question of how regulatory mechanisms responsible for normal circadian rhythms can be interfered with is addressed. Cancer chronochemotherapy today combined with modern infusional technology is a promising field for improving cancer treatment in general and reducing side effects and is expected to make important progress in the near future.

  10. Traumatic orbital encephalocele: Presentation and imaging.

    Science.gov (United States)

    Wei, Leslie A; Kennedy, Tabassum A; Paul, Sean; Wells, Timothy S; Griepentrog, Greg J; Lucarelli, Mark J

    2016-01-01

    Traumatic orbital encephalocele is a rare but severe complication of orbital roof fractures. We describe 3 cases of orbital encephalocele due to trauma in children. Retrospective case series from the University of Wisconsin - Madison and Medical College of Wisconsin. Three cases of traumatic orbital encephalocele in pediatric patients were found. The mechanism of injury was motor vehicle accident in 2 patients and accidental self-inflicted gunshot wound in 1 patient. All 3 patients sustained orbital roof fractures (4 mm to 19 mm in width) and frontal lobe contusions with high intracranial pressure. A key finding in all 3 cases was progression of proptosis and globe displacement 4 to 11 days after initial injury. On initial CT, all were diagnosed with extraconal hemorrhage adjacent to the roof fractures, with subsequent enlargement of the mass and eventual diagnosis of encephalocele. Orbital encephalocele is a severe and sight-threatening complication of orbital roof fractures. Post-traumatic orbital encephalocele can be challenging to diagnose on CT as patients with this condition often have associated orbital and intracranial hematoma, which can be difficult to distinguish from herniated brain tissue. When there is a high index of suspicion for encephalocele, an MRI of the orbits and brain with contrast should be obtained for additional characterization. Imaging signs that should raise suspicion for traumatic orbital encephalocele include an enlarging heterogeneous orbital mass in conjunction with a roof fracture and/or widening fracture segments.

  11. PS Booster Orbit Correction

    CERN Document Server

    Chanel, M; Rumolo, G; Tomás, R; CERN. Geneva. AB Department

    2008-01-01

    At the end of the 2007 run, orbit measurements were carried out in the 4 rings of the PS Booster (PSB) for different working points and beam energies. The aim of these measurements was to provide the necessary input data for a PSB realignment campaign during the 2007/2008 shutdown. Currently, only very few corrector magnets can be operated reliably in the PSB; therefore the orbit correction has to be achieved by displacing (horizontally and vertically) and/or tilting some of the defocusing quadrupoles (QDs). In this report we first describe the orbit measurements, followed by a detailed explanation of the orbit correction strategy. Results and conclusions are presented in the last section.

  12. On-Orbit 3-Dimensional Electrostatic Detumble for Generic Spacecraft Geometries

    Science.gov (United States)

    Bennett, Trevor J.

    with implementation of electrostatic detumble control on-orbit. Leveraging an extended Kalman filter scheme, the relative position information is readily obtained. In order to touchlessly acquire the target electrostatic potential, a nested two-time scale Kalman filter is employed to provide real-time estimates of both relative position and electrostatic potential while on-orbit. The culmination of the presented control formulations for generic spacecraft geometries, the proximity and formation flying control capability, and the availability of necessary state information provide significant contributions towards the viability of electrostatic detumble mission concepts.

  13. Crew appliance concepts. Volume 2, appendix B: Shuttle orbiter appliances supporting engineering data. [food management and personal hygiene

    Science.gov (United States)

    Proctor, B. W.; Reysa, R. P.; Russell, D. J.

    1975-01-01

    Technical data collected for the food management and personal hygiene appliances considered for the shuttle orbiter are presented as well as plotted and tabulated trade study results for each appliance. Food storage, food operation, galley cleanup, waste collection/transfer, body cleansing, and personal grooming were analyzed.

  14. Gene expression data from 4T1 irradiated tumors treated with TGFbeta blockade

    Data.gov (United States)

    National Aeronautics and Space Administration — Accumulating data support the concept that ionizing radiation therapy (RT) has the potential to convert the tumor into an in situ individualized vaccine; however...

  15. Use of Orbital Conformer to Improve Speech in Patients with Confluent Maxillectomy and Orbital Defects

    Science.gov (United States)

    Colebeck, Amanda C.; Kase, Michael T.; Nichols, Cindy B.; Golden, Marjorie; Huryn, Joseph M.

    2016-01-01

    The basic objective in prosthetic restoration of confluent maxillary and orbital defects is to achieve a comfortable, cosmetically acceptable prosthesis that restores speech, deglutition, and mastication. It is a challenging task complicated by the size and shape of the defects. The maxillary obturator prosthesis often satisfies the objective of adequate deglutition; however, orbital defects that are not obturated in the medial septal or posterior walls allow air to escape, negatively impacting phonation. This article describes a technique to achieve favorable prosthetic rehabilitation in a patient with a maxillectomy and ipsilateral orbital exenteration. The prosthetic components include maxillary obturator, orbital conformer, and orbital prosthesis connected using rigid magnetic attachments. PMID:25953143

  16. Robustness analysis method for orbit control

    Science.gov (United States)

    Zhang, Jingrui; Yang, Keying; Qi, Rui; Zhao, Shuge; Li, Yanyan

    2017-08-01

    Satellite orbits require periodical maintenance due to the presence of perturbations. However, random errors caused by inaccurate orbit determination and thrust implementation may lead to failure of the orbit control strategy. Therefore, it is necessary to analyze the robustness of the orbit control methods. Feasible strategies which are tolerant to errors of a certain magnitude can be developed to perform reliable orbit control for the satellite. In this paper, first, the orbital dynamic model is formulated by Gauss' form of the planetary equation using the mean orbit elements; the atmospheric drag and the Earth's non-spherical perturbations are taken into consideration in this model. Second, an impulsive control strategy employing the differential correction algorithm is developed to maintain the satellite trajectory parameters in given ranges. Finally, the robustness of the impulsive control method is analyzed through Monte Carlo simulations while taking orbit determination error and thrust error into account.

  17. United States Control Module Guidance, Navigation, and Control Subsystem Design Concept

    Science.gov (United States)

    Polites, M. E.; Bartlow, B. E.

    1997-01-01

    Should the Russian Space Agency (RSA) not participate in the International Space Station (ISS) program, then the United States (U.S.) National Aeronautics and Space Administration (NASA) may choose to execute the ISS mission. However, in order to do this, NASA must build two new space vehicles, which must perform the functions that the Russian vehicles and hardware were to perform. These functions include periodic ISS orbit reboost, initial ISS attitude control, and U.S. On-Orbit Segment (USOS) control Moment gyroscope (CMG) momentum desaturation. The two new NASA vehicles that must perform these functions are called the U.S. control module (USCM) and the U.S. resupply module. This paper presents a design concept for the USCM GN&C subsystem, which must play a major role in ISS orbit reboost and initial attitude control, plus USOS CMG momentum desaturation. The proposed concept is structured similar to the USOS GN&C subsystem, by design. It is very robust, in that it allows the USCM to assume a variety of vehicle attitudes and stay power-positive. It has a storage/safe mode that places the USCM in a gravity-gradient orientation and keeps it there for extended periods of time without consuming a great deal of propellant. Simulation results are presented and discussed that show the soundness of the design approach. An equipment list is included that gives detailed information on the baselined GN&C components.

  18. Orbiter OMS and RCS technology

    Science.gov (United States)

    Boudreaux, R. A.

    1982-01-01

    Orbiter Orbital Maneuver Subsystem (OMS) and Reaction Control Subsystem (RCS) tankage has proved to be highly successful in shuttle flights on-orbit propellant transfer tests were done. Tank qualification tests along with flight demonstrations were carried out future uses of storable propellants are cited.

  19. Proton and carbon ion radiotherapy for primary brain tumors and tumors of the skull base

    Energy Technology Data Exchange (ETDEWEB)

    Combs, Stephanie E.; Kessel, Kerstin; Habermehl, Daniel; Debus, Jurgen [Univ. Hospital of Heidelberg, Dept. of Radiation Oncology, Heidelberg (Germany)], e-mail: Stephanie.Combs@med.uni-heidelberg.de; Haberer, Thomas [Heidelberger Ionenstrahl Therapiezentrum (HIT), Heidelberg (Germany); Jaekel, Oliver [Univ. Hospital of Heidelberg, Dept. of Radiation Oncology, Heidelberg (Germany); Heidelberger Ionenstrahl Therapiezentrum (HIT), Heidelberg (Germany)

    2013-10-15

    To analyze clinical concepts, toxicity and treatment outcome in patients with brain and skull base tumors treated with photons and particle therapy. Material and methods: In total 260 patients with brain tumors and tumors of the skull base were treated at the Heidelberg Ion Therapy Center (HIT). Patients enrolled in and randomized within prospective clinical trials as well as bony or soft tissue tumors are not included in this analysis. Treatment was delivered as protons, carbon ions, or combinations of photons and a carbon ion boost. All patients are included in a tight follow-up program. The median follow-up time is 12 months (range 2-39 months). Results: Main histologies included meningioma (n = 107) for skull base lesions, pituitary adenomas (n = 14), low-grade gliomas (n = 51) as well as high-grade gliomas (n = 55) for brain tumors. In all patients treatment could be completed without any unexpected severe toxicities. No side effects > CTC Grade III were observed. To date, no severe late toxicities were observed, however, for endpoints such as secondary malignancies or neuro cognitive side effects follow-up time still remains too short. Local recurrences were mainly seen in the group of high-grade gliomas or atypical meningiomas; for benign skull base meningiomas, to date, no recurrences were observed during follow-up. Conclusion: The specific benefit of particle therapy will potentially reduce the risk of secondary malignancies as well as improve neuro cognitive outcome and quality of life (QOL); thus, longer follow-up will be necessary to confirm these endpoints. Indication-specific trials on meningiomas and gliomas are underway to elucidate the role of protons and carbon ions in these indications.

  20. Proton and carbon ion radiotherapy for primary brain tumors and tumors of the skull base

    International Nuclear Information System (INIS)

    Combs, Stephanie E.; Kessel, Kerstin; Habermehl, Daniel; Debus, Jurgen; Haberer, Thomas; Jaekel, Oliver

    2013-01-01

    To analyze clinical concepts, toxicity and treatment outcome in patients with brain and skull base tumors treated with photons and particle therapy. Material and methods: In total 260 patients with brain tumors and tumors of the skull base were treated at the Heidelberg Ion Therapy Center (HIT). Patients enrolled in and randomized within prospective clinical trials as well as bony or soft tissue tumors are not included in this analysis. Treatment was delivered as protons, carbon ions, or combinations of photons and a carbon ion boost. All patients are included in a tight follow-up program. The median follow-up time is 12 months (range 2-39 months). Results: Main histologies included meningioma (n = 107) for skull base lesions, pituitary adenomas (n = 14), low-grade gliomas (n = 51) as well as high-grade gliomas (n = 55) for brain tumors. In all patients treatment could be completed without any unexpected severe toxicities. No side effects > CTC Grade III were observed. To date, no severe late toxicities were observed, however, for endpoints such as secondary malignancies or neuro cognitive side effects follow-up time still remains too short. Local recurrences were mainly seen in the group of high-grade gliomas or atypical meningiomas; for benign skull base meningiomas, to date, no recurrences were observed during follow-up. Conclusion: The specific benefit of particle therapy will potentially reduce the risk of secondary malignancies as well as improve neuro cognitive outcome and quality of life (QOL); thus, longer follow-up will be necessary to confirm these endpoints. Indication-specific trials on meningiomas and gliomas are underway to elucidate the role of protons and carbon ions in these indications

  1. Glial heterotopia of the orbit: a rare cause of proptosis.

    Science.gov (United States)

    Bakhti, Souad; Terkmani, Fella; Tighilt, Nabila; Benmouma, Youcef; Boumehdi, Nazim; Djennas, Mohamed

    2016-11-01

    Glial heterotopia is defined as presence of normal glial tissue in an unusual location without connection with the brain. It is a very rare clinical entity occuring mostly in the head and neck region which is generally present at birth. Orbital location is very rare. We report a case of a 4-month-old girl presenting congenital proptosis with progressive increase. CT scan revealed an intraorbital mass without bony defect. The patient was operated, and resection was subtotal. Histologically, the tumor was composed of glial tissue with plexus choroid and pathologist concluded glial heterotopia. The child is under constant medical supervision because recurrences can be observed after incomplete resection; she had no new clinical signs at 18 months follow-up.

  2. [Secondary orbital lymphoma].

    Science.gov (United States)

    Basanta, I; Sevillano, C; Álvarez, M D

    2015-09-01

    A case is presented of an 85 year-old Caucasian female with lymphoma that recurred in the orbit (secondary ocular adnexal lymphoma). The orbital tumour was a diffuse large B-cell lymphoma according to the REAL classification (Revised European-American Lymphoma Classification). Orbital lymphomas are predominantly B-cell proliferations of a variety of histological types, and most are low-grade tumours. Patients are usually middle-aged or elderly, and it is slightly more common in women. A palpable mass, proptosis and blepharoptosis are the most common signs of presentation. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  3. Endoscopic-modified medial maxillectomy and its limitation for a solitary fibrous tumor of the lacrimal sac and nasolacrimal duct.

    Science.gov (United States)

    Moriyama, Munehito; Kodama, Satoru; Hirano, Takashi; Suzuki, Masashi

    2017-06-01

    Solitary fibrous tumor (SFT) is an uncommon neoplasm that usually arises from the pleura. Recently, SFTs have been reported in the head and neck region located in subsites such as the orbit. SFTs of the lacrimal sac are extremely rare, with only six cases reported in the English literature. We describe a SFT arising from the right lacrimal sac and extending along the nasolacrimal duct into the nasal cavity. Although, the tumor could not be removed by endoscopic-modified medial maxillectomy (EMMM) alone, combined approach with EMMM and a small external incision achieved the complete removal of the tumor. The patient has remained disease-free 24 months after surgery. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. JSC Orbital Debris Website Description

    Science.gov (United States)

    Johnson, Nicholas L.

    2006-01-01

    Purpose: The website provides information about the NASA Orbital Debris Program Office at JSC, which is the lead NASA center for orbital debris research. It is recognized world-wide for its leadership in addressing orbital debris issues. The NASA Orbital Debris Program Office has taken the international lead in conducting measurements of the environment and in developing the technical consensus for adopting mitigation measures to protect users of the orbital environment. Work at the center continues with developing an improved understanding of the orbital debris environment and measures that can be taken to control its growth. Major Contents: Orbital Debris research is divided into the following five broad efforts. Each area of research contains specific information as follows: 1) Modeling - NASA scientists continue to develop and upgrade orbital debris models to describe and characterize the current and future debris environment. Evolutionary and engineering models are described in detail. Downloadable items include a document in PDF format and executable software. 2) Measurements - Measurements of near-Earth orbital debris are accomplished by conducting ground-based and space-based observations of the orbital debris environment. The data from these sources provide validation of the environment models and identify the presence of new sources. Radar, optical and surface examinations are described. External links to related topics are provided. 3) Protection - Orbital debris protection involves conducting hypervelocity impact measurements to assess the risk presented by orbital debris to operating spacecraft and developing new materials and new designs to provide better protection from the environment with less weight penalty. The data from this work provides the link between the environment defined by the models and the risk presented by that environment to operating spacecraft and provides recommendations on design and operations procedures to reduce the risk as

  5. Direct therapeutic applications of calcium electroporation to effectively induce tumor necrosis

    DEFF Research Database (Denmark)

    Frandsen, Stine Krog; Gissel, Hanne; Hojman, Pernille

    2012-01-01

    in vivo. Calcium electroporation elicited dramatic antitumor responses in which 89% of treated tumors were eliminated. Histologic analyses indicated complete tumor necrosis. Mechanistically, calcium electroporation caused acute ATP depletion likely due to a combination of increased cellular use of ATP......, decreased production of ATP due to effects on the mitochondria, as well as loss of ATP through the permeabilized cell membrane. Taken together, our findings offer a preclinical proof of concept for the use of electroporation to load cancer cells with calcium as an efficient anticancer treatment...

  6. Orbits in weak and strong bars

    CERN Document Server

    Contopoulos, George

    1980-01-01

    The authors study the plane orbits in simple bar models embedded in an axisymmetric background when the bar density is about 1% (weak), 10% (intermediate) or 100% (strong bar) of the axisymmetric density. Most orbits follow the stable periodic orbits. The basic families of periodic orbits are described. In weak bars with two Inner Lindblad Resonances there is a family of stable orbits extending from the center up to the Outer Lindblad Resonance. This family contains the long period orbits near corotation. Other stable families appear between the Inner Lindblad Resonances, outside the Outer Lindblad Resonance, around corotation (short period orbits) and around the center (retrograde). Some families become unstable or disappear in strong bars. A comparison is made with cases having one or no Inner Lindblad Resonance. (12 refs).

  7. Radiation as an inducer of in-situ autologous vaccine in the treatment of solid tumors

    International Nuclear Information System (INIS)

    Ahmed, Mansoor M.

    2013-01-01

    Radiation therapy (RT) is conventionally used for local tumor control. Although local control of the primary tumor can prevent the development of subsequent systemic metastases, tumor irradiation is not effective in controlling pre-existing systemic disease. The concept of radiation-enhanced antigen presentation and immunomodulation allows the harnessing of tumor cell death induced by radiation as a potential source of tumor antigens for immunotherapy. Immunomodulation using RT is a novel strategy of in situ tumor vaccination where primary tumor irradiation can contribute to the control of pre-existing systemic metastatic disease. The absence of systemic immunosuppression (often associated with chemotherapy) and the generally lower toxicity makes radiation a desirable adjuvant regimen for immunotherapy and tumor vaccination strategies. Increased understanding of tumor immunology and the biology of radiation-mediated immune modulation should enhance the efficacy of combining these therapeutic modalities. Here we aim to provide an overview of the biology of radiation-induced immune modulation. (author)

  8. The Eccentric Behavior of Nearly Frozen Orbits

    Science.gov (United States)

    Sweetser, Theodore H.; Vincent, Mark A.

    2013-01-01

    Frozen orbits are orbits which have only short-period changes in their mean eccentricity and argument of periapse, so that they basically keep a fixed orientation within their plane of motion. Nearly frozen orbits are those whose eccentricity and argument of periapse have values close to those of a frozen orbit. We call them "nearly" frozen because their eccentricity vector (a vector whose polar coordinates are eccentricity and argument of periapse) will stay within a bounded distance from the frozen orbit eccentricity vector, circulating around it over time. For highly inclined orbits around the Earth, this distance is effectively constant over time. Furthermore, frozen orbit eccentricity values are low enough that these orbits are essentially eccentric (i.e., off center) circles, so that nearly frozen orbits around Earth are bounded above and below by frozen orbits.

  9. GLONASS orbit/clock combination in VNIIFTRI

    Science.gov (United States)

    Bezmenov, I.; Pasynok, S.

    2015-08-01

    An algorithm and a program for GLONASS satellites orbit/clock combination based on daily precise orbits submitted by several Analytic Centers were developed. Some theoretical estimates for combine orbit positions RMS were derived. It was shown that under condition that RMS of satellite orbits provided by the Analytic Centers during a long time interval are commensurable the RMS of combine orbit positions is no greater than RMS of other satellite positions estimated by any of the Analytic Centers.

  10. Nucleon molecular orbitals and the transition mechanism between molecular orbitals in nucleus-nucleus collisions

    International Nuclear Information System (INIS)

    Imanishi, B.; Misono, S.; von Oertzen, W.; Voit, H.

    1988-08-01

    The molecular orbitals of the nucleon(s) in nucleus-nucleus collisions are dynamically defined as a linear combination of nucleon single-particle orbits (LCNO) in a rotating frame by using the coupled-reaction-channel (CRC) theory. Nucleon molecular orbitals and the promotions of nucleon, - especially due to the Landau-Zener radial coupling are discussed with the method above mentioned. (author)

  11. European sail tower SPS [Solar Power Satellite] concept

    Energy Technology Data Exchange (ETDEWEB)

    Seboldt, W.; Leipold, M.; Hanowski, N. [Institute of Space Sensor Technology and Planetary Exploration, Cologne (Germany). German Aerospace Center; Klimke, M. [HOPE Worldwide Deutschland, Berlin (Germany)

    2001-06-01

    Based on a DLR-study in 1998/99 on behalf of ESA/ESTEC called ''System Concepts, Architectures and Technologies for Space Exploration and Utilization (SE and U)'' a new design for an Earth-orbiting Solar Power Satellite (SPS) has been developed. The design is called ''European Sail Tower SPS'' and consists mainly of deplorable sail-like structures derived from the ongoing DLR/ESA solar sail technology development activity. Such an SPS satellite features an extremely light-weight and large tower-like orbital system and could supply Europe with significant amounts of electrical power generated by photovoltaic cells and subsequently transmitted to earth via microwaves. In order to build up the sail tower, 60 units - each consisting of a pair of square-shaped sails - are moved from LEO to GEO with electric propulsion and successively assembled in GEO robotically on a central strut. Each single sail has dimensions of 150 m x 150 m and is automatically deployed, using four diagonal lightweight carbon fiber (CFRP) booms which are initially rolled up on a central hub. The electric thrusters for the transport to GEO could also be used for orbit and attitude control of the assembled tower which has a total length of about 15 km and would be mainly gravity gradient stabilized. Employing thin film solar cell technology, each sail is used as a solar array and produces an electric power in orbit of about 3.7 MW{sub e}. A microwave antenna with a diameter of 1 km transmits the power to a 10 km rectenna on the ground. The total mass of this 450 MW SPS is about 2100 tons. First estimates indicate that the costs for one kWh delivered in this way could compete with present day energy costs, if launch costs would decrease by two orders of magnitude. Furthermore, mass production and large numbers of installed SPS systems must be assumed in order to lower significantly the production costs and to reduce the influence of the expensive technology

  12. Tumor attributes predicting cutaneous metastatic destiny: a report of two interesting cases.

    Science.gov (United States)

    Gurumurthi, Ravichandran; Thirumalai, Raja; Easow, Jose M; Mohan, Subhashini

    2014-07-01

    Cutaneous metastases are the result of complex interaction between the tumor cells ("seed") and the host environment ("soil"). Metastases to the skin can be an early sign of internal malignancy or represent recurrence of the primary tumor and portends a poorer prognosis. Invasion and metastasis are the hallmarks of on cogenesis. Skin is the largest organ in the body, but the incidence of metastases is low. With advances in molecular biology, factors responsible for the initiation and perpetuation of metastatic tumor cells at distant sites are being elucidated. The concept of "pre-metastatic niche" and interaction between various chemokines has given a new outlook in understanding the organ specificity of metastatic tumor cells. We present two cases of cutaneous metastases with interesting clinical findings correlating with its biologic subtypes.

  13. Virtual Reality Tumor Resection: The Force Pyramid Approach.

    Science.gov (United States)

    Sawaya, Robin; Bugdadi, Abdulgadir; Azarnoush, Hamed; Winkler-Schwartz, Alexander; Alotaibi, Fahad E; Bajunaid, Khalid; AlZhrani, Gmaan A; Alsideiri, Ghusn; Sabbagh, Abdulrahman J; Del Maestro, Rolando F

    2017-09-05

    The force pyramid is a novel visual representation allowing spatial delineation of instrument force application during surgical procedures. In this study, the force pyramid concept is employed to create and quantify dominant hand, nondominant hand, and bimanual force pyramids during resection of virtual reality brain tumors. To address 4 questions: Do ergonomics and handedness influence force pyramid structure? What are the differences between dominant and nondominant force pyramids? What is the spatial distribution of forces applied in specific tumor quadrants? What differentiates "expert" and "novice" groups regarding their force pyramids? Using a simulated aspirator in the dominant hand and a simulated sucker in the nondominant hand, 6 neurosurgeons and 14 residents resected 8 different tumors using the CAE NeuroVR virtual reality neurosurgical simulation platform (CAE Healthcare, Montréal, Québec and the National Research Council Canada, Boucherville, Québec). Position and force data were used to create force pyramids and quantify tumor quadrant force distribution. Force distribution quantification demonstrates the critical role that handedness and ergonomics play on psychomotor performance during simulated brain tumor resections. Neurosurgeons concentrate their dominant hand forces in a defined crescent in the lower right tumor quadrant. Nondominant force pyramids showed a central peak force application in all groups. Bimanual force pyramids outlined the combined impact of each hand. Distinct force pyramid patterns were seen when tumor stiffness, border complexity, and color were altered. Force pyramids allow delineation of specific tumor regions requiring greater psychomotor ability to resect. This information can focus and improve resident technical skills training. Copyright © 2017 by the Congress of Neurological Surgeons

  14. A case report of orbital Langerhans cell histiocytosis presenting as a orbital cellulitis.

    Science.gov (United States)

    Albert-Fort, M; González-Candial, M

    2018-04-08

    A 10-year-old girl was seen with a 3-week history of right upper lid swelling and with no other symptoms or fever. There was no recent history of sinusitis, trauma, or previous infection involving the periorbital area, or response to oral antibiotic treatment. Orbital computed tomography showed a lesion involving the upper margin of the orbit, and bone destruction at the orbital roof. Biopsy performed revealed the presence of Langerhans cell Histiocytosis. The lesion was surgically debulked and corticosteroids were used intra-operatively. The lesion responded to treatment. The orbital involvement of Langerhans cell histiocytosis, despite its low incidence, should be considered in the examination of acute peri-orbital swelling. It usually presents as an osteolytic lesion, and it is confirmed with a histological examination and immunohistochemical techniques for CD1a and S100. An interdisciplinary approach is recommended to rule out multifocal or multisystemic diseases, as well as to develop an appropriate treatment strategy. Copyright © 2018 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Quantitative evaluation of orbital hybridization in carbon nanotubes under radial deformation using π-orbital axis vector

    Directory of Open Access Journals (Sweden)

    Masato Ohnishi

    2015-04-01

    Full Text Available When a radial strain is applied to a carbon nanotube (CNT, the increase in local curvature induces orbital hybridization. The effect of the curvature-induced orbital hybridization on the electronic properties of CNTs, however, has not been evaluated quantitatively. In this study, the strength of orbital hybridization in CNTs under homogeneous radial strain was evaluated quantitatively. Our analyses revealed the detailed procedure of the change in electronic structure of CNTs. In addition, the dihedral angle, the angle between π-orbital axis vectors of adjacent atoms, was found to effectively predict the strength of local orbital hybridization in deformed CNTs.

  16. The conservation of orbital symmetry

    CERN Document Server

    Woodward, R B

    2013-01-01

    The Conservation of Orbital Symmetry examines the principle of conservation of orbital symmetry and its use. The central content of the principle was that reactions occur readily when there is congruence between orbital symmetry characteristics of reactants and products, and only with difficulty when that congruence does not obtain-or to put it more succinctly, orbital symmetry is conserved in concerted reaction. This principle is expected to endure, whatever the language in which it may be couched, or whatever greater precision may be developed in its application and extension. The book ope

  17. Similarity in Bilateral Isolated Internal Orbital Fractures.

    Science.gov (United States)

    Chen, Hung-Chang; Cox, Jacob T; Sanyal, Abanti; Mahoney, Nicholas R

    2018-04-13

    In evaluating patients sustaining bilateral isolated internal orbital fractures, the authors have observed both similar fracture locations and also similar expansion of orbital volumes. In this study, we aim to investigate if there is a propensity for the 2 orbits to fracture in symmetrically similar patterns when sustaining similar trauma. A retrospective chart review was performed studying all cases at our institution of bilateral isolated internal orbital fractures involving the medial wall and/or the floor at the time of presentation. The similarity of the bilateral fracture locations was evaluated using the Fisher's exact test. The bilateral expanded orbital volumes were analyzed using the Wilcoxon signed-rank test to assess for orbital volume similarity. Twenty-four patients with bilateral internal orbital fractures were analyzed for fracture location similarity. Seventeen patients (70.8%) had 100% concordance in the orbital subregion fractured, and the association between the right and the left orbital fracture subregion locations was statistically significant (P < 0.0001). Fifteen patients were analyzed for orbital volume similarity. The average orbital cavity volume was 31.2 ± 3.8 cm on the right and 32.0 ± 3.7 cm on the left. There was a statistically significant difference between right and left orbital cavity volumes (P = 0.0026). The data from this study suggest that an individual who suffers isolated bilateral internal orbital fractures has a statistically significant similarity in the location of their orbital fractures. However, there does not appear to be statistically significant similarity in the expansion of the orbital volumes in these patients.

  18. Orbital Debris and NASA's Measurement Program

    Science.gov (United States)

    Africano, J. L.; Stansbery, E. G.

    2002-05-01

    Since the launch of Sputnik in 1957, the number of manmade objects in orbit around the Earth has dramatically increased. The United States Space Surveillance Network (SSN) tracks and maintains orbits on over nine thousand objects down to a limiting diameter of about ten centimeters. Unfortunately, active spacecraft are only a small percentage ( ~ 7%) of this population. The rest of the population is orbital debris or ``space junk" consisting of expended rocket bodies, dead payloads, bits and pieces from satellite launches, and fragments from satellite breakups. The number of these smaller orbital debris objects increases rapidly with decreasing size. It is estimated that there are at least 130,000 orbital debris objects between one and ten centimeters in diameter. Most objects smaller than 10 centimeters go untracked! As the orbital debris population grows, the risk to other orbiting objects, most importantly manned space vehicles, of a collision with a piece of debris also grows. The kinetic energy of a solid 1 cm aluminum sphere traveling at an orbital velocity of 10 km/sec is equivalent to a 400 lb. safe traveling at 60 mph. Fortunately, the volume of space in which the orbiting population resides is large, collisions are infrequent, but they do occur. The Space Shuttle often returns to earth with its windshield pocked with small pits or craters caused by collisions with very small, sub-millimeter-size pieces of debris (paint flakes, particles from solid rocket exhaust, etc.), and micrometeoroids. To get a more complete picture of the orbital-debris environment, NASA has been using both radar and optical techniques to monitor the orbital debris environment. This paper gives an overview of the orbital debris environment and NASA's measurement program.

  19. Orbital structure in oscillating galactic potentials

    Science.gov (United States)

    Terzić, Balša; Kandrup, Henry E.

    2004-01-01

    Subjecting a galactic potential to (possibly damped) nearly periodic, time-dependent variations can lead to large numbers of chaotic orbits experiencing systematic changes in energy, and the resulting chaotic phase mixing could play an important role in explaining such phenomena as violent relaxation. This paper focuses on the simplest case of spherically symmetric potentials subjected to strictly periodic driving with the aim of understanding precisely why orbits become chaotic and under what circumstances they will exhibit systematic changes in energy. Four unperturbed potentials V0(r) were considered, each subjected to a time dependence of the form V(r, t) =V0(r)(1 +m0 sinωt). In each case, the orbits divide clearly into regular and chaotic, distinctions which appear absolute. In particular, transitions from regularity to chaos are seemingly impossible. Over finite time intervals, chaotic orbits subdivide into what can be termed `sticky' chaotic orbits, which exhibit no large-scale secular changes in energy and remain trapped in the phase-space region where they started; and `wildly' chaotic orbits, which do exhibit systematic drifts in energy as the orbits diffuse to different phase-space regions. This latter distinction is not absolute, transitions corresponding apparently to orbits penetrating a `leaky' phase-space barrier. The three different orbit types can be identified simply in terms of the frequencies for which their Fourier spectra have the most power. An examination of the statistical properties of orbit ensembles as a function of driving frequency ω allows us to identify the specific resonances that determine orbital structure. Attention focuses also on how, for fixed amplitude m0, such quantities as the mean energy shift, the relative measure of chaotic orbits and the mean value of the largest Lyapunov exponent vary with driving frequency ω and how, for fixed ω, the same quantities depend on m0.

  20. Orbital roof encephalocele mimicking a destructive neoplasm.

    Science.gov (United States)

    Alsuhaibani, Adel H; Hitchon, Patrick W; Smoker, Wendy R K; Lee, Andrew G; Nerad, Jeffrey A

    2011-01-01

    The purpose of this case report is to report an orbital roof encephalocele mimicking a destructive orbital neoplasm. Orbital roof encephalocele is uncommon but can mimic neoplasm. One potential mechanism for the orbital roof destruction is a post-traumatic "growing orbital roof fracture." The growing fracture has been reported mostly in children but can occur in adults. Alternative potential etiologies for the encephalocele are discussed, including Gorham syndrome. Orbital roof encephalocele is uncommon in adults, and the findings can superficially resemble an orbital neoplasm. Radiographic and clinical features that might suggest the correct diagnosis include a prior history of trauma, overlying frontal lobe encephalomalacia without significant mass effect or edema, and an orbital roof defect. The "growing fracture" mechanism may be a potential explanation for the orbital roof destruction in some cases.

  1. The globe and orbit in Laron syndrome.

    Science.gov (United States)

    Kornreich, L; Konen, O; Lilos, P; Laron, Z

    2011-09-01

    Patients with LS have an inborn growth hormone resistance, resulting in failure to generate IGF-1. The purpose of this study was to evaluate the size of the eye and orbit in LS. We retrospectively reviewed the MR imaging of the brain in 9 patients with LS for the following parameters: axial diameter of the globe, interzygomatic distance, perpendicular distance from the interzygomatic line to margins of the globe, medial-to-lateral diameter of the orbit at the anterior orbital rim, distance from the anterior orbital rim to the anterior globe, maximal distance between the medial walls of the orbits, lateral orbital wall angle, lateral orbital wall length, and mediolateral thickness of the intraorbital fat in the most cranial image of the orbit. All measurements were made bilaterally. Twenty patients referred for MR imaging for unrelated reasons served as control subjects. Compared with the control group, the patients with LS had a significantly smaller maximal globe diameter and shallower but wider orbits due to a shorter lateral wall, a smaller medial distance between the orbits, and a larger angle of the orbit. The ratio between the most anterior orbital diameter and the globe was greater than that in controls. The position of the globe was more anterior in relation to the interzygomatic line. Shallow and wide orbits and small globes relative to orbital size are seen in LS and may be secondary to IGF-1 deficiency.

  2. Orbiting compressor for residential air-conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Kim, Woo Young; Ahn, Jong Min [Department of Mechanical Engineering, University of Incheon, 12-1 Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea)

    2010-01-15

    A new type of compressor, called an orbiting compressor, is introduced in this paper. The orbiting compressor is characterized by an orbiting piston, and the piston or orbiter consists of a circular base plate and a ring type vane protruding vertically from the base plate. The orbiter is made to orbit in an annular space formed between two concentric circular walls via an Oldham-ring mechanism, producing two sealed gas pockets on both sides of the vane wrap with a 180 phase difference. This operating mechanism leads to alternating compression and discharge processes, which results in low torque variation. The orbiting compressor has been designed for an R410A residential air conditioner with a cooling capacity of 10.0 kW. The performance of the orbiting compressor model has been analytically investigated, where the volumetric, adiabatic and mechanical efficiencies were calculated to be 94.8%, 90.4% and 93.4%, respectively for the ARI condition. The EER was estimated to be about 10.86 with a motor efficiency of 89%. (author)

  3. Artist concept illustrating key events on day by day basis during Apollo 9

    Science.gov (United States)

    1969-01-01

    Artist concept illustrating key events on day by day basis during Apollo 9 mission. First photograph illustrates activities on the first day of the mission, including flight crew preparation, orbital insertion, 103 north mile orbit, separations, docking and docked Service Propulsion System Burn (19792); Second day events include landmark tracking, pitch maneuver, yaw-roll maneuver, and high apogee orbits (19793); Third day events include crew transfer and Lunar Module system evaluation (19794); Fourth day events include use of camera, day-night extravehicular activity, use of golden slippers, and television over Texas and Louisiana (19795); Fifth day events include vehicles undocked, Lunar Module burns for rendezvous, maximum separation, ascent propulsion system burn, formation flying and docking, and Lunar Module jettison ascent burn (19796); Sixth thru ninth day events include service propulsion system burns and landmark sightings, photograph special tests (19797); Tenth day events i

  4. Water Recovery System Architecture and Operational Concepts to Accommodate Dormancy

    Science.gov (United States)

    Carter, Layne; Tabb, David; Anderson, Molly

    2017-01-01

    Future manned missions beyond low Earth orbit will include intermittent periods of extended dormancy. The mission requirement includes the capability for life support systems to support crew activity, followed by a dormant period of up to one year, and subsequently for the life support systems to come back online for additional crewed missions. NASA personnel are evaluating the architecture and operational concepts that will allow the Water Recovery System (WRS) to support such a mission. Dormancy could be a critical issue due to concerns with microbial growth or chemical degradation that might prevent water systems from operating properly when the crewed mission began. As such, it is critical that the water systems be designed to accommodate this dormant period. This paper identifies dormancy issues, concepts for updating the WRS architecture and operational concepts that will enable the WRS to support the dormancy requirement.

  5. Intracavitary mould brachytherapy in malignant tumors of the maxilla

    International Nuclear Information System (INIS)

    Rosenblatt, Edward; Blumenfeld, Israel; Cederbaum, Martin; Kuten, Abraham

    1996-01-01

    Purpose: To integrate brachytherapy in the combined modality management of malignant tumors of the maxilla, as a means of increasing the radiotherapy dose to the tumor bed while avoiding high doses to the orbital contents. Materials and methods: Following a partial or total maxillectomy, a duplication of the interim surgical obturator was created using a wash of vinyl polysiloxane. This mould was used as a carrier for afterloading nylon catheters through which 192-Iridium seed-ribbons were inserted. Following brachytherapy, selected patients also received external beam irradiation. Results and discussion: After a median follow-up of 36 months, 9 out of 11 patients are alive and disease-free; 1 developed a local recurrence and another relapsed at another site in the oral cavity. Transient grade 1 - 2 mucositis at the implant site was observed in all patients. The review of computer isodose distributions showed that the average dose received by the homolateral eyeball was 10% (range 9,2 - 10.0) of the prescribed surface dose to the surgical cavity. Conclusions: Brachytherapy can be integrated in the management of patients with malignant tumors of the maxilla in the form of a custom-made intracavitary mould carrying 192-Iridium sources. We found this technique particularly useful in cases with close or positive surgical margins

  6. Titan Orbiter Aerorover Mission with Enceladus Science (TOAMES)

    Science.gov (United States)

    Sittler, E.; Cooper, J.; Mahaffy, P.; Fairbrother, D.; de Pater, I.; Schulze-Makuch, D.; Pitman, J.

    2007-08-01

    organic chemistry on the surface. The Aerorover will probably use a "hot air" Montgolfier balloon concept using the waste heat from the MMRTG ~1-2 kwatts. New technologies will need to be developed and miniaturization will be required to maintain functionality while controlling mass, power and cost. Duty cycling will be used. The Aerorover will have all the instruments needed to sample Titan's atmosphere and surface with possible methane lakes-rivers. It will e.g., use multi-spectral imagers and for last 6 months of mission, balloon payload will land on surface at predetermined site to take core samples of the surface and use seismometers to help probe the interior. All remote (and active) sensors on the orbiter will share a ~1 meter telescope, called MIDAS (Multiple Instrument Distributed Aperture Sensor). MIDAS observations in stable orbit at Titan can provide full global maps of Titan's surface and could additionally provide long term observations of the Saturn system including Enceladus for extended mission phases over many years, potentially for decades. Experience from the Hubble Space Telescope has shown strong public interest and commitment to exciting generational missions.

  7. Exoplanet Yield Estimation for Decadal Study Concepts using EXOSIMS

    Science.gov (United States)

    Morgan, Rhonda; Lowrance, Patrick; Savransky, Dmitry; Garrett, Daniel

    2016-01-01

    The anticipated upcoming large mission study concepts for the direct imaging of exo-earths present an exciting opportunity for exoplanet discovery and characterization. While these telescope concepts would also be capable of conducting a broad range of astrophysical investigations, the most difficult technology challenges are driven by the requirements for imaging exo-earths. The exoplanet science yield for these mission concepts will drive design trades and mission concept comparisons.To assist in these trade studies, the Exoplanet Exploration Program Office (ExEP) is developing a yield estimation tool that emphasizes transparency and consistent comparison of various design concepts. The tool will provide a parametric estimate of science yield of various mission concepts using contrast curves from physics-based model codes and Monte Carlo simulations of design reference missions using realistic constraints, such as solar avoidance angles, the observatory orbit, propulsion limitations of star shades, the accessibility of candidate targets, local and background zodiacal light levels, and background confusion by stars and galaxies. The python tool utilizes Dmitry Savransky's EXOSIMS (Exoplanet Open-Source Imaging Mission Simulator) design reference mission simulator that is being developed for the WFIRST Preliminary Science program. ExEP is extending and validating the tool for future mission concepts under consideration for the upcoming 2020 decadal review. We present a validation plan and preliminary yield results for a point design.

  8. Optimization of the occulter for the Solar Orbiter/METIS coronagraph

    Science.gov (United States)

    Landini, Federico; Vivès, Sébastien; Romoli, Marco; Guillon, Christophe; Pancrazzi, Maurizio; Escolle, Clement; Focardi, Mauro; Antonucci, Ester; Fineschi, Silvano; Naletto, Giampiero; Nicolini, Gianalfredo; Nicolosi, Piergiorgio; Spadaro, Daniele

    2012-09-01

    METIS (Multi Element Telescope for Imaging and Spectroscopy investigation), selected to fly aboard the Solar Orbiter ESA/NASA mission, is conceived to perform imaging (in visible, UV and EUV) and spectroscopy (in EUV) of the solar corona, by means of an integrated instrument suite located on a single optical bench and sharing the same aperture on the satellite heat shield. As every coronagraph, METIS is highly demanding in terms of stray light suppression. Coronagraphs history teaches that a particular attention must be dedicated to the occulter optimization. The METIS occulting system is of particular interest due to its innovative concept. In order to meet the strict thermal requirements of Solar Orbiter, METIS optical design has been optimized by moving the entrance pupil at the level of the external occulter on the S/C thermal shield, thus reducing the size of the external aperture. The scheme is based on an inverted external-occulter (IEO). The IEO consists of a circular aperture on the Solar Orbiter thermal shield. A spherical mirror rejects back the disk-light through the IEO. A breadboard of the occulting assembly (BOA) has been manufactured in order to perform stray light tests in front of two solar simulators (in Marseille, France and in Torino, Italy). A first measurement campaign has been carried on at the Laboratoire d'Astrophysique de Marseille. In this paper we describe the BOA design, the laboratory set-up and the preliminary results.

  9. Multicolor microRNA FISH effectively differentiates tumor types

    Science.gov (United States)

    Renwick, Neil; Cekan, Pavol; Masry, Paul A.; McGeary, Sean E.; Miller, Jason B.; Hafner, Markus; Li, Zhen; Mihailovic, Aleksandra; Morozov, Pavel; Brown, Miguel; Gogakos, Tasos; Mobin, Mehrpouya B.; Snorrason, Einar L.; Feilotter, Harriet E.; Zhang, Xiao; Perlis, Clifford S.; Wu, Hong; Suárez-Fariñas, Mayte; Feng, Huichen; Shuda, Masahiro; Moore, Patrick S.; Tron, Victor A.; Chang, Yuan; Tuschl, Thomas

    2013-01-01

    MicroRNAs (miRNAs) are excellent tumor biomarkers because of their cell-type specificity and abundance. However, many miRNA detection methods, such as real-time PCR, obliterate valuable visuospatial information in tissue samples. To enable miRNA visualization in formalin-fixed paraffin-embedded (FFPE) tissues, we developed multicolor miRNA FISH. As a proof of concept, we used this method to differentiate two skin tumors, basal cell carcinoma (BCC) and Merkel cell carcinoma (MCC), with overlapping histologic features but distinct cellular origins. Using sequencing-based miRNA profiling and discriminant analysis, we identified the tumor-specific miRNAs miR-205 and miR-375 in BCC and MCC, respectively. We addressed three major shortcomings in miRNA FISH, identifying optimal conditions for miRNA fixation and ribosomal RNA (rRNA) retention using model compounds and high-pressure liquid chromatography (HPLC) analyses, enhancing signal amplification and detection by increasing probe-hapten linker lengths, and improving probe specificity using shortened probes with minimal rRNA sequence complementarity. We validated our method on 4 BCC and 12 MCC tumors. Amplified miR-205 and miR-375 signals were normalized against directly detectable reference rRNA signals. Tumors were classified using predefined cutoff values, and all were correctly identified in blinded analysis. Our study establishes a reliable miRNA FISH technique for parallel visualization of differentially expressed miRNAs in FFPE tumor tissues. PMID:23728175

  10. Applicability of meteor radiant determination methods depending on orbit type. I. High-eccentric orbits

    Science.gov (United States)

    Svoren, J.; Neslusan, L.; Porubcan, V.

    1993-07-01

    It is evident that there is no uniform method of calculating meteor radiants which would yield reliable results for all types of cometary orbits. In the present paper an analysis of this problem is presented, together with recommended methods for various types of orbits. Some additional methods resulting from mathematical modelling are presented and discussed together with Porter's, Steel-Baggaley's and Hasegawa's methods. In order to be able to compare how suitable the application of the individual radiant determination methods is, it is necessary to determine the accuracy with which they approximate real meteor orbits. To verify the accuracy with which the orbit of a meteoroid with at least one node at 1 AU fits the original orbit of the parent body, we applied the Southworth-Hawkins D-criterion (Southworth, R.B., Hawkins, G.S.: 1963, Smithson. Contr. Astrophys 7, 261). D0.2 the fit is rather poor and the change of orbit unrealistic. The optimal methods with the smallest values of D for given types of orbits are shown in two series of six plots. The new method of rotation around the line of apsides we propose is very appropriate in the region of small inclinations. There is no doubt that Hasegawa's omega-adjustment method (Hasegawa, I.: 1990, Publ. Astron. Soc. Japan 42, 175) has the widest application. A comparison of the theoretical radiants with the observed radiants of seven known meteor showers is also presented.

  11. Tumor-Associated Macrophages and Neutrophils in Tumor Microenvironment

    Directory of Open Access Journals (Sweden)

    Jaehong Kim

    2016-01-01

    Full Text Available Distinct tumor microenvironment forms in each progression step of cancer and has diverse capacities to induce both adverse and beneficial consequences for tumorigenesis. It is now known that immune cells can be activated to favor tumor growth and progression, most probably influenced by the tumor microenvironment. Tumor-associated macrophages and tumor-associated neutrophils can exert protumoral functions, enhancing tumor cell invasion and metastasis, angiogenesis, and extracellular matrix remodeling, while inhibiting the antitumoral immune surveillance. Considering that neutrophils in inflammatory environments recruit macrophages and that recruited macrophages affect neutrophil functions, there may be various degrees of interaction between tumor-associated macrophages and tumor-associated neutrophils. Platelets also play an important role in the recruitment and regulation of monocytic and granulocytic cells in the tumor tissues, suggesting that platelet function may be essential for generation of tumor-associated macrophages and tumor-associated neutrophils. In this review, we will explore the biology of tumor-associated macrophages and tumor-associated neutrophils and their possible interactions in the tumor microenvironment. Special attention will be given to the recruitment and activation of these tumor-associated cells and to the roles they play in maintenance of the tumor microenvironment and progression of tumors.

  12. A Concept for Providing Warning of Chelyabinsk-like Meteors, including those approaching from the Sun

    Science.gov (United States)

    Dunham, D. W.; Reitsema, H.; Lu, E.; Arentz, R.; Linfield, R.; Chapman, C. R.; Farquhar, R. W.; Furfaro, R.; Eismont, N. A.; Ledkov, A.; Chumachenko, E.

    2013-12-01

    The detonation of a 20m-asteroid above Chelyabinsk, Russia on 2013 February 15 shows that even small asteroids can cause extensive damage. Earth-based telescopes have found smaller harmless objects, such as 2008 TC3, discovered 20h before it exploded over northern Sudan . 2008 TC3 remains the only asteroid discovered before it hit Earth because it approached Earth from the night side, where it was observed by large telescopes searching for near-Earth objects. The larger object that exploded over Chelyabinsk approached Earth from the day side, from too close to the Sun to be detected from Earth. A sizeable telescope in an orbit about the Sun-Earth L1 (SE-L1) libration point 1.5 million km from Earth towards the Sun (about 4 times the distance to the Moon) could find objects like the 'Chelyabinsk' asteroid approaching approximately from the line of sight to the Sun about a day before Earth closest approach; this would find the approximately 35% of asteroids that approach Earth from a direction too close to the Sun to be observed, or likely to be missed, from the ground. Our concept would give at least several hours, and often a day or more, to take protective measures, rather than the approximately two-minute interval between the flash and shock wave arrival that occurred in Chelyabinsk. An important reason for providing warning of these events, even smaller harmless ones that explode high in the atmosphere with the force of an atomic bomb, is to prevent mistaking such an event for a nuclear attack that could trigger a devastating nuclear war. This concept could also discover many small asteroids that would not impact Earth; some of them would likely be suitable for retrieval to move to a lunar orbit for study by astronauts in the next decade. A concept using a space telescope similar to that needed by our concept is already conceived by the B612 Foundation, whose planned Sentinel Space Telescope could find nearly all 140m and larger near-Earth objects (NEO

  13. A study on mammary gland tumors in rats born of parents irradiated before mating

    International Nuclear Information System (INIS)

    Strel'tsova, V.N.; Pavlenko-Mikhajlov, Yu.N.; Oshchepkov, A.B.

    1982-01-01

    The effect of exposure of male or female rats to radiation 5 days before conception on the frequency of development of mammary tumors in their progeny is described. It was shown that mammary tumor incidence and the rate of their development increase in a population of female rats-descendants of one of parents exposed. Irradiation of would-be mothers produced a stronger blastogenic reaction in their progeny than that of fathers

  14. The SPQR experiment: detecting damage to orbiting spacecraft with ground-based telescopes

    Science.gov (United States)

    Paolozzi, Antonio; Porfilio, Manfredi; Currie, Douglas G.; Dantowitz, Ronald F.

    2007-09-01

    The objective of the Specular Point-like Quick Reference (SPQR) experiment was to evaluate the possibility of improving the resolution of ground-based telescopic imaging of manned spacecraft in orbit. The concept was to reduce image distortions due to atmospheric turbulence by evaluating the Point Spread Function (PSF) of a point-like light reference and processing the spacecraft image accordingly. The target spacecraft was the International Space Station (ISS) and the point-like reference was provided by a laser beam emitted by the ground station and reflected back to the telescope by a Cube Corner Reflector (CCR) mounted on an ISS window. The ultimate objective of the experiment was to demonstrate that it is possible to image spacecraft in Low Earth Orbit (LEO) with a resolution of 20 cm, which would have probably been sufficient to detect the damage which caused the Columbia disaster. The experiment was successfully performed from March to May 2005. The paper provides an overview of the SPQR experiment.

  15. Orbital tomography: Molecular band maps, momentum maps and the imaging of real space orbitals of adsorbed molecules

    Energy Technology Data Exchange (ETDEWEB)

    Offenbacher, Hannes; Lüftner, Daniel; Ules, Thomas; Reinisch, Eva Maria; Koller, Georg, E-mail: georg.koller@uni-graz.at; Puschnig, Peter; Ramsey, Michael G., E-mail: michael.ramsey@uni-graz.at

    2015-10-01

    Highlights: • Orbital tomography within the plane wave final state approximation. • One electron orbital predictions versus angle resolved photoemission experiment. • Geometric and electronic structure of organic thin films elucidated by ARUPS. • Influence of molecular conformation and orientation on ARUPS. • Retrieval of sexiphenyl and pentacene orbitals in real space. - Abstract: The frontier orbitals of molecules are the prime determinants of their chemical, optical and electronic properties. Arguably, the most direct method of addressing the (filled) frontier orbitals is ultra-violet photoemission spectroscopy (UPS). Although UPS is a mature technique from the early 1970s on, the angular distribution of the photoemitted electrons was thought to be too complex to be analysed quantitatively. Recently angle resolved UPS (ARUPS) work on conjugated molecules both, in ordered thick films and chemisorbed monolayers, has shown that the angular (momentum) distribution of the photocurrent from orbital emissions can be simply understood. The approach, based on the assumption of a plane wave final state is becoming known as orbital tomography. Here we will demonstrate, with selected examples of pentacene (5A) and sexiphenyl (6P), the potential of orbital tomography. First it will be shown how the full angular distribution of the photocurrent (momentum map) from a specific orbital is related to the real space orbital by a Fourier transform. Examples of the reconstruction of 5A orbitals will be given and the procedure for recovering the lost phase information will be outlined. We then move to examples of sexiphenyl where we interrogate the original band maps of thick sexiphenyl in the light of our understanding of orbital tomography that has developed since then. With comparison to theoretical simulations of the molecular band maps, the molecular conformation and orientation will be concluded. New results for the sexiphenyl monolayer on Al(1 1 0) will then be

  16. A nuclear powered pulsed inductive plasma accelerator as a viable propulsion concept for advanced OTV space applications

    International Nuclear Information System (INIS)

    Tapper, M.L.

    1982-01-01

    An electric propulsion concept suitable for delivering heavy payloads from low earth orbit (LEO) to high energy earth orbit is proposed. The system consists of a number of pulsed inductive plasma thrusters powered by a 100 kWe space nuclear power system. The pulsed plasma thruster is a relatively simple electrodeless device. It also exhibits adequate conversion to thrust power in the desired I sub sp regime of 1500 to 3000 seconds for optimal payload transfer from low earth to high earth orbit. Because of these features and the fact that the nuclear power unit will be capable of delivering sustained high power levels throughout the duration of any given mission, the system presented appears to be a very promising propulsion candidate for advanced orbital transfer vehicle (OTV) applications. An OTV, which makes use of this propulsion system and which has been designed to lift a 9000-lb payload into geosynchronous earth orbit, (GEO) is also examined

  17. Permanent Habitats in Earth-Sol/Mars-Sol Orbit Positions

    Science.gov (United States)

    Greenspon, J.

    Project Outpost is a manned Earth-Sol/Mars-Sol platform that enables permanent occupation in deep space. In order to develop the program elements for this complex mission, Project Outpost will rely primarily on existing/nearterm technology and hardware for the construction of its components. For the purposes of this study, four mission requirements are considered: 1. Outpost - Man's 1st purpose-produced effort of space engineering, in which astructure is developed/constructed in an environment completely alien to currentpractices for EVA guidelines. 2. Newton - a concept study developed at StarGate Research, for the development ofa modified Hohmann personnel orbital transport operating between Earth andMars. Newton would serve as the primary crew delivery apparatus throughrepeatable transfer scheduling for all Earth-Lpoint-Mars activities. Thispermanent "transit system" would establish the foundations for Solar systemcolonization. 3. Cruis - a concept study developed at StarGate Research, for the development of amodified Hohmann cargo orbital transport operating between Earth and Mars.Cruis would serve as the primary equipment delivery apparatus throughrepeatable transfer scheduling for all Earth-Lpoint-Mars activities. Thispermanent "transit system" would establish the foundations for Solar systemcolonization, and 4. Ares/Diana - a more conventional space platform configuration for Lunar andMars orbit is included as a construction baseline. The operations of these assetsare supported, and used for the support, of the outpost. Outpost would be constructed over a 27-year period of launch opportunities into Earth-Sol or Mars-Sol Lagrange orbit (E-S/M-S L1, 4 or 5). The outpost consists of an operations core with a self-contained power generation ability, a docking and maintenance structure, a Scientific Research complex and a Habitation Section. After achieving initial activation, the core will provide the support and energy required to operate the outpost in a 365

  18. Quark Orbital Angular Momentum

    Directory of Open Access Journals (Sweden)

    Burkardt Matthias

    2015-01-01

    Full Text Available Definitions of orbital angular momentum based on Wigner distributions are used as a framework to discuss the connection between the Ji definition of the quark orbital angular momentum and that of Jaffe and Manohar. We find that the difference between these two definitions can be interpreted as the change in the quark orbital angular momentum as it leaves the target in a DIS experiment. The mechanism responsible for that change is similar to the mechanism that causes transverse single-spin asymmetries in semi-inclusive deep-inelastic scattering.

  19. Wilms' tumor: past, present and (possibly) future.

    Science.gov (United States)

    Spreafico, Filippo; Bellani, Franca Fossati

    2006-02-01

    Wilms' tumor is one of the successes of pediatric oncology, with an overall cure rate of over 85%, using relatively simple therapies. This excellent outcome has been the result of collaborative efforts among surgeons, pediatricians, pathologists and radiation oncologists. The results that have been achieved in children with Wilms' tumors support the strong value of the multidisciplinary team approach to cancer. The two largest cooperative groups that have studied the optimum treatment for Wilms' tumor are the National Wilms' Tumor Study group in North America and the International Society of Pediatric Oncology, involving European and other countries. The National Wilms' Tumor Study group recommends primary surgery before any adjuvant treatment, whereas the International Society of Pediatric Oncology trials are based on the use of preoperative chemotherapy. The debate on primary chemotherapy versus primary nephrectomy appears to have been overcome, in the sense that the advantages and disadvantages of these two diverse methods have emerged from large and well-performed clinical trials, and comparably low doses of anthracyclines and radiotherapy are now used. Challenges remain in identifying novel molecular, histological and clinical risk factors for stratification of treatment intensity. This could allow a safe reduction in therapy for patients known to have an excellent chance of cure with the current therapy, while identifying, at diagnosis, the minority of children at risk of relapse, who will necessitate more aggressive treatments. Another positive factor is the substantial progress that has been made in the cure for recurrent patients, with long-term survivals shifting from 30 to almost 60% in more recently treated patients with intensive-dose chemotherapy regimens. The combination of lower relapses and higher salvage rates translated into significantly improved overall survival for Wilms' tumor patients as a whole. This review covers current concepts on

  20. Stellar orbits around Sgr A*

    International Nuclear Information System (INIS)

    Trippe, S; Gillessen, S; Ott, T; Eisenhauer, F; Paumard, T; Martins, F; Genzel, R; Schoedel, R; Eckart, A; Alexander, T

    2006-01-01

    In this article we present and discuss the latest results from the observations of stars (''S-stars'') orbiting Sgr A* . With improving data quality the number of observed S-stars has increased substantially in the last years. The combination of radial velocity and proper motion information allows an ever more precise determination of orbital parameters and of the mass of and the distance to the supermassive black hole in the centre of the Milky Way. Additionally, the orbital solutions allow us to verify an agreement between the NIR source Sgr A* and the dynamical centre of the stellar orbits to within 2 mas

  1. Endocrine tumors other than thyroid tumors

    International Nuclear Information System (INIS)

    Takeichi, Norio; Dohi, Kiyohiko

    1992-01-01

    This paper discusses the tendency for the occurrence of tumors in the endocrine glands, other than the thyroid gland, in A-bomb survivors using both autopsy and clinical data. ABCC-RERF sample data using 4136 autopsy cases (1961-1977) revealed parathyroid tumors in 13 A-bomb survivors, including 3 with the associated hyperparathyroidism, with the suggestion of dose-dependent increase in the occurrence of tumors. Based on clinical data from Hiroshima University, 7 (46.7%) of 15 parathyroid tumors cases were A-bomb survivors. Data (1974-1987) from the Tumor Registry Committee (TRC) in Hiroshima Prefecture revealed that a relative risk of parathyroid tumors was 5.6 times higher in the entire group of A-bomb survivors and 16.2 times higher in the group of heavily exposed A-bomb survivors, suggesting the dose-dependent increase in their occurrence. Adrenal tumors were detected in 47 of 123 cases from the TRC data, and 15 (31.5%) of these 47 were A-bomb survivors. Particularly, 11 cases of adrenal tumors associated with Cushing syndrome included 6 A-bomb survivors (54.5%). The incidence of multiple endocrine gonadial tumors (MEGT) tended to be higher with increasing exposure doses; and the 1-9 rad group, the 10-99 rad group, and the 100 or more rad group had a risk of developing MEGT of 4.1, 5.7, and 7.1, respectively, relative to both the not-in the city group and the 0 rad group. These findings suggested that there is a correlation between A-bomb radiation and the occurrence of parathyroid tumors (including hyperparathyroidism), adrenal tumors associated with Cushing syndrome and MEGT (especially, the combined thyroid and ovarian tumors and the combined thyroid and parathyroid tumors). (N.K.)

  2. Role of T lymphocytes in tumor response to radiotherapy

    Directory of Open Access Journals (Sweden)

    Sandra eDemaria

    2012-08-01

    Full Text Available Over thirty years ago, Helen Stone and colleagues compared the effects of local tumor irradiation in immunocompetent and T-cell deficient mice, providing the first evidence that tumor response to radiotherapy is impaired in the absence of a normal T cell repertoire. In the following three decades there has been an exponential growth in understanding T cells and the complex molecular mechanisms that regulate their activation, migration to tumors and effector functions. We now also know that tumor progression is intrinsically linked to the development of multiple immunosuppressive mechanisms that allow cancer cells to escape immune control. Recent evidence about the role of T cells in determining the prognosis and outcome of patients at any clinical stages of cancer has been instrumental in re-directing the concept of immunosurveillance and immunoediting from the realm of preclinical models to the reality of clinical observations. Importantly, cell death induced by standard anti-cancer therapies like chemotherapy and radiation has demonstrated to involve the immune system and, in certain specific settings, enable a specific immune response. It is, therefore, not surprising that the last few years have seen an increase in investigations exploring how to harness the ability of radiation to induce anti-tumor immune responses. We will review here the experimental evidence that anti-tumor T cells are key players in tumor control achieved by radiotherapy. The effects of radiation on the tumor that have been shown to enhance the priming and effector phases of anti-tumor immunity will be discussed. Finally, we will highlight promising combinations of immune response modifiers that enhance T cell function with radiotherapy that are being tested in the clinic.

  3. Role of T lymphocytes in tumor response to radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Demaria, Sandra [Department of Pathology, New York University School of Medicine and NYU Langone Medical Center, New York, NY (United States); Formenti, Silvia C., E-mail: sandra.demaria@nyumc.org [Department of Radiation Oncology, New York University School of Medicine and NYU Langone Medical Center, New York, NY (United States)

    2012-08-24

    Over thirty years ago, Helen Stone and colleagues compared the effects of local tumor irradiation in immunocompetent and T cell deficient mice, providing the first evidence that tumor response to radiotherapy is impaired in the absence of a normal T cell repertoire. In the following three decades there has been an exponential growth in understanding T cells and the complex molecular mechanisms that regulate their activation, migration to tumors and effector functions. We now also know that tumor progression is intrinsically linked to the development of multiple immunosuppressive mechanisms that allow cancer cells to escape immune control. Recent evidence about the role of T cells in determining the prognosis and outcome of patients at any clinical stages of cancer has been instrumental in re-directing the concept of immunosurveillance and immunoediting from the realm of preclinical models to the reality of clinical observations. Importantly, cell death induced by standard anti-cancer therapies like chemotherapy and radiation has been demonstrated to involve the immune system and, in certain specific settings, enable a specific immune response. It is, therefore, not surprising that the last few years have seen an increase in investigations exploring how to harness the ability of radiation to induce anti-tumor immune responses. We will review here the experimental evidence that anti-tumor T cells are key players in tumor control achieved by radiotherapy. The effects of radiation on the tumor that have been shown to enhance the priming and effector phases of anti-tumor immunity will be discussed. Finally, we will highlight promising combinations of immune response modifiers that enhance T cell function with radiotherapy which are being tested in the clinic.

  4. Role of T lymphocytes in tumor response to radiotherapy

    International Nuclear Information System (INIS)

    Demaria, Sandra; Formenti, Silvia C.

    2012-01-01

    Over thirty years ago, Helen Stone and colleagues compared the effects of local tumor irradiation in immunocompetent and T cell deficient mice, providing the first evidence that tumor response to radiotherapy is impaired in the absence of a normal T cell repertoire. In the following three decades there has been an exponential growth in understanding T cells and the complex molecular mechanisms that regulate their activation, migration to tumors and effector functions. We now also know that tumor progression is intrinsically linked to the development of multiple immunosuppressive mechanisms that allow cancer cells to escape immune control. Recent evidence about the role of T cells in determining the prognosis and outcome of patients at any clinical stages of cancer has been instrumental in re-directing the concept of immunosurveillance and immunoediting from the realm of preclinical models to the reality of clinical observations. Importantly, cell death induced by standard anti-cancer therapies like chemotherapy and radiation has been demonstrated to involve the immune system and, in certain specific settings, enable a specific immune response. It is, therefore, not surprising that the last few years have seen an increase in investigations exploring how to harness the ability of radiation to induce anti-tumor immune responses. We will review here the experimental evidence that anti-tumor T cells are key players in tumor control achieved by radiotherapy. The effects of radiation on the tumor that have been shown to enhance the priming and effector phases of anti-tumor immunity will be discussed. Finally, we will highlight promising combinations of immune response modifiers that enhance T cell function with radiotherapy which are being tested in the clinic.

  5. Orbital and adnexal sarcoidosis

    NARCIS (Netherlands)

    Prabhakaran, Venkatesh C.; Saeed, Perooz; Esmaeli, Bita; Sullivan, Timothy J.; Mcnab, Alan; Davis, Garry; Valenzuela, Alejandra; Leibovitch, Igal; Kesler, Anat; Sivak-Callcott, Jennifer; Hoyama, Erika; Selva, Dinesh

    2007-01-01

    To present the clinical features and management in a series of patients with orbital and adnexal sarcoidosis. This multicenter retrospective study included patients with biopsy-proven noncaseating granuloma involving the orbit or adnexa and evidence of systemic sarcoidosis. Clinical records were

  6. Field-free deterministic ultrafast creation of magnetic skyrmions by spin-orbit torques

    Science.gov (United States)

    Büttner, Felix; Lemesh, Ivan; Schneider, Michael; Pfau, Bastian; Günther, Christian M.; Hessing, Piet; Geilhufe, Jan; Caretta, Lucas; Engel, Dieter; Krüger, Benjamin; Viefhaus, Jens; Eisebitt, Stefan; Beach, Geoffrey S. D.

    2017-11-01

    Magnetic skyrmions are stabilized by a combination of external magnetic fields, stray field energies, higher-order exchange interactions and the Dzyaloshinskii-Moriya interaction (DMI). The last favours homochiral skyrmions, whose motion is driven by spin-orbit torques and is deterministic, which makes systems with a large DMI relevant for applications. Asymmetric multilayers of non-magnetic heavy metals with strong spin-orbit interactions and transition-metal ferromagnetic layers provide a large and tunable DMI. Also, the non-magnetic heavy metal layer can inject a vertical spin current with transverse spin polarization into the ferromagnetic layer via the spin Hall effect. This leads to torques that can be used to switch the magnetization completely in out-of-plane magnetized ferromagnetic elements, but the switching is deterministic only in the presence of a symmetry-breaking in-plane field. Although spin-orbit torques led to domain nucleation in continuous films and to stochastic nucleation of skyrmions in magnetic tracks, no practical means to create individual skyrmions controllably in an integrated device design at a selected position has been reported yet. Here we demonstrate that sub-nanosecond spin-orbit torque pulses can generate single skyrmions at custom-defined positions in a magnetic racetrack deterministically using the same current path as used for the shifting operation. The effect of the DMI implies that no external in-plane magnetic fields are needed for this aim. This implementation exploits a defect, such as a constriction in the magnetic track, that can serve as a skyrmion generator. The concept is applicable to any track geometry, including three-dimensional designs.

  7. Charge and Spin Transport in Spin-orbit Coupled and Topological Systems

    KAUST Repository

    Ndiaye, Papa Birame

    2017-10-31

    In the search for low power operation of microelectronic devices, spin-based solutions have attracted undeniable increasing interest due to their intrinsic magnetic nonvolatility. The ability to electrically manipulate the magnetic order using spin-orbit interaction, associated with the recent emergence of topological spintronics with its promise of highly efficient charge-to-spin conversion in solid state, offer alluring opportunities in terms of system design. Although the related technology is still at its infancy, this thesis intends to contribute to this engaging field by investigating the nature of the charge and spin transport in spin-orbit coupled and topological systems using quantum transport methods. We identified three promising building blocks for next-generation technology, three classes of systems that possibly enhance the spin and charge transport efficiency: (i)- topological insulators, (ii)- spin-orbit coupled magnonic systems, (iii)- topological magnetic textures (skyrmions and 3Q magnetic state). Chapter 2 reviews the basics and essential concepts used throughout the thesis: the spin-orbit coupling, the mathematical notion of topology and its importance in condensed matter physics, then topological magnetism and a zest of magnonics. In Chapter 3, we study the spin-orbit torques at the magnetized interfaces of 3D topological insulators. We demonstrated that their peculiar form, compared to other spin-orbit torques, have important repercussions in terms of magnetization reversal, charge pumping and anisotropic damping. In Chapter 4, we showed that the interplay between magnon current jm and magnetization m in homogeneous ferromagnets with Dzyaloshinskii-Moriya (DM) interaction, produces a field-like torque as well as a damping-like torque. These DM torques mediated by spin wave can tilt the imeaveraged magnetization direction and are similar to Rashba torques for electronic systems. Moreover, the DM torque is more efficient when magnons are

  8. Sizing of "Mother Ship and Catcher" Concepts for LEO Small Debris Capture

    Science.gov (United States)

    Bacon, John B.

    2009-01-01

    Most Low Earth Orbit (LEO) debris lies in a limited number of inclination "bands" associated with launch latitudes, or with specific useful orbit inclinations (such as polar orbits). Such narrow inclination bands generally have a uniform spread over all possible Right Ascensions of Ascending Node (RAANs), creating a different orbit plane for nearly every piece of debris. This complicates concept of rendezvous and capture for debris removal. However, a low-orbiting satellite will always phase in RAAN faster than debris objects in higher orbits at the same inclination, potentially solving the problem. Such a base can serve as a single space-based launch facility (a "mother ship") that can tend and then send tiny individual catcher devices for each debris object, as the facility drifts into the same RAAN as the higher object. This presentation will highlight characteristic system requirements of such an architecture, including structural and navigation requirements, power, mass and dV budgets for both the mother ship and the mass-produced common catcher devices that would clean out selected inclination bands. The altitude and inclination regime over which a band is to be cleared, the size distribution of the debris, and the inclusion of additional mission priorities all affect the sizing of the system. It is demonstrated that major LEO hazardous debris reductions can be realized in each band with a single LEO launch of a single mother ship, with simple attached catchers of total mass less than typical commercial LEO launch capability.

  9. Algorithms for orbit control on SPEAR

    International Nuclear Information System (INIS)

    Corbett, J.; Keeley, D.; Hettel, R.; Linscott, I.; Sebek, J.

    1994-06-01

    A global orbit feedback system has been installed on SPEAR to help stabilize the position of the photon beams. The orbit control algorithms depend on either harmonic reconstruction of the orbit or eigenvector decomposition. The orbit motion is corrected by dipole corrector kicks determined from the inverse corrector-to-bpm response matrix. This paper outlines features of these control algorithms as applied to SPEAR

  10. Regulatory T cells as suppressors of anti-tumor immunity: Role of metabolism.

    Science.gov (United States)

    De Rosa, Veronica; Di Rella, Francesca; Di Giacomo, Antonio; Matarese, Giuseppe

    2017-06-01

    Novel concepts in immunometabolism support the hypothesis that glucose consumption is also used to modulate anti-tumor immune responses, favoring growth and expansion of specific cellular subsets defined in the past as suppressor T cells and currently reborn as regulatory T (Treg) cells. During the 1920s, Otto Warburg and colleagues observed that tumors consumed high amounts of glucose compared to normal tissues, even in the presence of oxygen and completely functioning mitochondria. However, the role of the Warburg Effect is still not completely understood, particularly in the context of an ongoing anti-tumor immune response. Current experimental evidence suggests that tumor-derived metabolic restrictions can drive T cell hyporesponsiveness and immune tolerance. For example, several glycolytic enzymes, deregulated in cancer, contribute to tumor progression independently from their canonical metabolic activity. Indeed, they can control apoptosis, gene expression and activation of specific intracellular pathways, thus suggesting a direct link between metabolic switches and pro-tumorigenic transcriptional programs. Focus of this review is to define the specific metabolic pathways controlling Treg cell immunobiology in the context of anti-tumor immunity and tumor progression. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Orbital Resonances in the Vinti Solution

    Science.gov (United States)

    Zurita, L. D.

    As space becomes more congested, contested, and competitive, high-accuracy orbital predictions become critical for space operations. Current orbit propagators use the two-body solution with perturbations added, which have significant error growth when numerically integrated for long time periods. The Vinti Solution is a more accurate model than the two-body problem because it also accounts for the equatorial bulge of the Earth. Unfortunately, the Vinti solution contains small divisors near orbital resonances in the perturbative terms of the Hamiltonian, which lead to inaccurate orbital predictions. One approach to avoid the small divisors is to apply transformation theory, which is presented in this research. The methodology of this research is to identify the perturbative terms of the Vinti Solution, perform a coordinate transformation, and derive the new equations of motion for the Vinti system near orbital resonances. An analysis of these equations of motion offers insight into the dynamics found near orbital resonances. The analysis in this research focuses on the 2:1 resonance, which includes the Global Positioning System. The phase portrait of a nominal Global Positioning System satellite orbit is found to contain a libration region and a chaotic region. Further analysis shows that the dynamics of the 2:1 resonance affects orbits with semi-major axes ranging from -5.0 to +5.4 kilometers from an exactly 2:1 resonant orbit. Truth orbits of seven Global Positioning System satellites are produced for 10 years. Two of the satellites are found to be outside of the resonance region and three are found to be influenced by the libration dynamics of the resonance. The final satellite is found to be influenced by the chaotic dynamics of the resonance. This research provides a method of avoiding the small divisors found in the perturbative terms of the Vinti Solution near orbital resonances.

  12. The Radiological Spectrum of Orbital Pathologies that Involve the Lacrimal Gland and the Lacrimal Fossa

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Won Sang; Ahn, Kook Jin; Park, Mi Ra; Kim, Ji Young; Choi, Jae Jeong; Kim, Bum Soo; Hahn, Seong Tai [Catholic University College of Medicine, Seoul (Korea, Republic of)

    2007-08-15

    CT and MRI are utilized to differentiate between different types of masses and to determine the extent of lesions involving the lacrimal gland and the fossa. In lacrimal gland epithelial tumors, benign pleomorphic adenomas are seen most commonly with a well defined benign appearance, and a malignant adenoid cystic carcinoma is seen with a typical invasive malignant appearance. However, a malignant myoepithelial carcinoma is seen with a benign looking appearance. Lymphomatous lesions of the lacrimal gland include a broad spectrum ranging from reactive hyperplasia to malignant lymphoma. These lesions can be very difficult to differentiate both radiologically and pathologically. Generally, lymphomas tend to occur in older patients. The developmental cystic lesions found in the lacrimal fossa such as dermoid and epidermoid cysts can be diagnosed when the cyst involves the superior temporal quadrant of the orbit and manifests as a nonenhancing cystic mass and, in case of a lipoma, it is diagnosed as a total fatty mass. However, masses of granulocytic sarcoma and xanthogranuloma, as well as vascular masses, such as a hemangiopericytoma, are difficult to diagnose correctly on the basis of preoperative imaging findings alone. Clinically, the lesions of the lacrimal gland and fossa are found as palpable masses in the superior lateral aspect of the orbit, and these lesions constitute about 5-13% of all of the orbital masses confirmed by biopsy. Many different pathological entities arise from the lacrimal gland and fossa, and as each of them requires a different therapeutic approach, the radiological characterization of each lesion is important. Approximately, half of the lacrimal gland masses are tumors of epithelial origin and the rest are lesions that arise from lymphoid or inflammatory diseases. Pseudotumors, metastatic masses and developmental cysts may also occur in the lacrimal fossa. This paper aims to discuss the radiologic findings of the lesions that are found in

  13. The Radiological Spectrum of Orbital Pathologies that Involve the Lacrimal Gland and the Lacrimal Fossa

    International Nuclear Information System (INIS)

    Jung, Won Sang; Ahn, Kook Jin; Park, Mi Ra; Kim, Ji Young; Choi, Jae Jeong; Kim, Bum Soo; Hahn, Seong Tai

    2007-01-01

    CT and MRI are utilized to differentiate between different types of masses and to determine the extent of lesions involving the lacrimal gland and the fossa. In lacrimal gland epithelial tumors, benign pleomorphic adenomas are seen most commonly with a well defined benign appearance, and a malignant adenoid cystic carcinoma is seen with a typical invasive malignant appearance. However, a malignant myoepithelial carcinoma is seen with a benign looking appearance. Lymphomatous lesions of the lacrimal gland include a broad spectrum ranging from reactive hyperplasia to malignant lymphoma. These lesions can be very difficult to differentiate both radiologically and pathologically. Generally, lymphomas tend to occur in older patients. The developmental cystic lesions found in the lacrimal fossa such as dermoid and epidermoid cysts can be diagnosed when the cyst involves the superior temporal quadrant of the orbit and manifests as a nonenhancing cystic mass and, in case of a lipoma, it is diagnosed as a total fatty mass. However, masses of granulocytic sarcoma and xanthogranuloma, as well as vascular masses, such as a hemangiopericytoma, are difficult to diagnose correctly on the basis of preoperative imaging findings alone. Clinically, the lesions of the lacrimal gland and fossa are found as palpable masses in the superior lateral aspect of the orbit, and these lesions constitute about 5-13% of all of the orbital masses confirmed by biopsy. Many different pathological entities arise from the lacrimal gland and fossa, and as each of them requires a different therapeutic approach, the radiological characterization of each lesion is important. Approximately, half of the lacrimal gland masses are tumors of epithelial origin and the rest are lesions that arise from lymphoid or inflammatory diseases. Pseudotumors, metastatic masses and developmental cysts may also occur in the lacrimal fossa. This paper aims to discuss the radiologic findings of the lesions that are found in

  14. EUSO@TurLab: An experimental replica of ISS orbits

    Directory of Open Access Journals (Sweden)

    Bertaina M.

    2015-01-01

    Full Text Available The EUSO@TurLab project is an on-going activity aimed to reproduce atmospheric and luminous conditions that JEM-EUSO will encounter on its orbits around the Earth. The use of the TurLab facility, part of the Department of Physics of the University of Torino, allows the simulation of different surface conditions in a very dark and rotating environment in order to test the response of JEM-EUSO's sensors and sensitivity. The experimental setup currently in operation has been used to check the potential of the TurLab facility for the above purposes, and the acquired data will be used to test the concept of JEM-EUSO's trigger system.

  15. Tumor cell-derived microparticles polarize M2 tumor-associated macrophages for tumor progression.

    Science.gov (United States)

    Ma, Ruihua; Ji, Tiantian; Chen, Degao; Dong, Wenqian; Zhang, Huafeng; Yin, Xiaonan; Ma, Jingwei; Liang, Xiaoyu; Zhang, Yi; Shen, Guanxin; Qin, Xiaofeng; Huang, Bo

    2016-04-01

    Despite identification of macrophages in tumors (tumor-associated macrophages, TAM) as potential targets for cancer therapy, the origin and function of TAM in the context of malignancy remain poorly characterized. Here, we show that microparticles (MPs), as a by-product, released by tumor cells act as a general mechanism to mediate M2 polarization of TAM. Taking up tumor MPs by macrophages is a very efficient process, which in turn results in the polarization of macrophages into M2 type, not only leading to promoting tumor growth and metastasis but also facilitating cancer stem cell development. Moreover, we demonstrate that the underlying mechanism involves the activation of the cGAS/STING/TBK1/STAT6 pathway by tumor MPs. Finally, in addition to murine tumor MPs, we show that human counterparts also possess consistent effect on human M2 polarization. These findings provide new insights into a critical role of tumor MPs in remodeling of tumor microenvironment and better understanding of the communications between tumors and macrophages.

  16. Orbit determination for ISRO satellite missions

    Science.gov (United States)

    Rao, Ch. Sreehari; Sinha, S. K.

    Indian Space Research Organisation (ISRO) has been successful in using the in-house developed orbit determination and prediction software for satellite missions of Bhaskara, Rohini and APPLE. Considering the requirements of satellite missions, software packages are developed, tested and their accuracies are assessed. Orbit determination packages developed are SOIP, for low earth orbits of Bhaskara and Rohini missions, ORIGIN and ODPM, for orbits related to all phases of geo-stationary missions and SEGNIP, for drift and geo-stationary orbits. Software is tested and qualified using tracking data of SIGNE-3, D5-B, OTS, SYMPHONIE satellites with the help of software available with CNES, ESA and DFVLR. The results match well with those available from these agencies. These packages have supported orbit determination successfully throughout the mission life for all ISRO satellite missions. Member-Secretary

  17. Targeting carbonic anhydrase IX by nitroimidazole based sulfamides enhances the therapeutic effect of tumor irradiation: A new concept of dual targeting drugs

    International Nuclear Information System (INIS)

    Dubois, Ludwig; Peeters, Sarah G.J.A.; Kuijk, Simon J.A. van; Yaromina, Ala; Lieuwes, Natasja G.; Saraya, Ruchi; Biemans, Rianne; Rami, Marouan; Parvathaneni, Nanda Kumar; Vullo, Daniela; Vooijs, Marc; Supuran, Claudiu T.; Winum, Jean-Yves

    2013-01-01

    Background and purpose: Carbonic anhydrase IX (CAIX) plays an important role in pH regulation processes critical for tumor cell growth and metastasis. We hypothesize that a dual targeting bioreductive nitroimidazole based anti-CAIX sulfamide drug (DH348) will reduce tumor growth and sensitize tumors to irradiation in a CAIX dependent manner. Material and methods: The effect of the dual targeting anti-CAIX (DH348) and its single targeting control drugs on extracellular acidification and radiosensitivity was examined in HT-29 colorectal carcinoma cells. Tumor growth and time to reach 4× start volume (T4×SV) was monitored for animals receiving DH348 (10 mg/kg) combined with tumor single dose irradiation (10 Gy). Results: In vitro, DH348 reduced hypoxia-induced extracellular acidosis, but did not change hypoxic radiosensitivity. In vivo, DH348 monotherapy decreased tumor growth rate and sensitized tumors to radiation (enhancement ratio 1.50) without systemic toxicity only for CAIX expressing tumors. Conclusions: A newly designed nitroimidazole and sulfamide dual targeting drug reduces hypoxic extracellular acidification, slows down tumor growth at nontoxic doses and sensitizes tumors to irradiation all in a CAIX dependent manner, suggesting no “off-target” effects. Our data therefore indicate the potential utility of a dual drug approach as a new strategy for tumor-specific targeting

  18. Ultra-fast three terminal perpendicular spin-orbit torque MRAM (Presentation Recording)

    Science.gov (United States)

    Boulle, Olivier; Cubukcu, Murat; Hamelin, Claire; Lamard, Nathalie; Buda-Prejbeanu, Liliana; Mikuszeit, Nikolai; Garello, Kevin; Gambardella, Pietro; Langer, Juergen; Ocker, Berthold; Miron, Mihai; Gaudin, Gilles

    2015-09-01

    The discovery that a current flowing in a heavy metal can exert a torque on a neighboring ferromagnet has opened a new way to manipulate the magnetization at the nanoscale. This "spin orbit torque" (SOT) has been demonstrated in ultrathin magnetic multilayers with structural inversion asymmetry (SIA) and high spin orbit coupling, such as Pt/Co/AlOx multilayers. We have shown that this torque can lead to the magnetization switching of a perpendicularly magnetized nanomagnet by an in-plane current injection. The manipulation of magnetization by SOT has led to a novel concept of magnetic RAM memory, the SOT-MRAM, which combines non volatility, high speed, reliability and large endurance. These features make the SOT-MRAM a good candidate to replace SRAM for non-volatile cache memory application. We will present the proof of concept of a perpendicular SOT-MRAM cell composed of a Ta/FeCoB/MgO/FeCoB magnetic tunnel junction and demonstrate ultra-fast (down to 300 ps) deterministic bipolar magnetization switching. Macrospin and micromagnetic simulations including SOT cannot reproduce the experimental results, which suggests that additional physical mechanisms are at stacks. Our results show that SOT-MRAM is fast, reliable and low power, which is promising for non-volatile cache memory application. We will also discuss recent experiments of magnetization reversal in ultrathin multilayers Pt/Co/AlOx by very short (<200 ps) current pulses. We will show that in this material, the Dzyaloshinskii-Moryia interaction plays a key role in the reversal process.

  19. Space Tourism: Orbital Debris Considerations

    Science.gov (United States)

    Mahmoudian, N.; Shajiee, S.; Moghani, T.; Bahrami, M.

    2002-01-01

    Space activities after a phase of research and development, political competition and national prestige have entered an era of real commercialization. Remote sensing, earth observation, and communication are among the areas in which this growing industry is facing competition and declining government money. A project like International Space Station, which draws from public money, has not only opened a window of real multinational cooperation, but also changed space travel from a mere fantasy into a real world activity. Besides research activities for sending man to moon and Mars and other outer planets, space travel has attracted a considerable attention in recent years in the form of space tourism. Four countries from space fairing nations are actively involved in the development of space tourism. Even, nations which are either in early stages of space technology development or just beginning their space activities, have high ambitions in this area. This is worth noting considering their limited resources. At present, trips to space are available, but limited and expensive. To move beyond this point to generally available trips to orbit and week long stays in LEO, in orbital hotels, some of the required basic transportations, living requirements, and technological developments required for long stay in orbit are already underway. For tourism to develop to a real everyday business, not only the price has to come down to meaningful levels, but also safety considerations should be fully developed to attract travelers' trust. A serious hazard to space activities in general and space tourism in particular is space debris in earth orbit. Orbiting debris are man-made objects left over by space operations, hazardous to space missions. Since the higher density of debris population occurs in low earth orbit, which is also the same orbit of interest to space tourism, a careful attention should be paid to the effect of debris on tourism activities. In this study, after a

  20. The German joint research project "concepts for future gravity satellite missions"

    Science.gov (United States)

    Reubelt, Tilo; Sneeuw, Nico; Fichter, Walter; Müller, Jürgen

    2010-05-01

    Within the German joint research project "concepts for future gravity satellite missions", funded by the Geotechnologies programme of the German Federal Ministry of Education and Research, options and concepts for future satellite missions for precise (time-variable) gravity field recovery are investigated. The project team is composed of members from science and industry, bringing together experts in geodesy, satellite systems, metrology, sensor technology and control systems. The majority of team members already contributed to former gravity missions. The composition of the team guarantees that not only geodetic aspects and objectives are investigated, but also technological and financial constraints are considered. Conversely, satellite, sensor and system concepts are developed and improved in a direct exchange with geodetic and scientific claims. The project aims to develop concepts for both near and mid-term future satellite missions, taking into account e.g. advanced satellite formations and constellations, improved orbit design, innovative metrology and sensor systems and advances in satellite systems.