  1. Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    International Nuclear Information System (INIS)

    Berther, Ralph; Eckhardt, Boris; Zollikofer, Christoph L.; Patak, Michael A.; Erturk, Sukru M.

    2008-01-01

    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P<0.001), homogeneity of the luminal content (P<0.001), delineation of the bowel-wall to the lumen (P<0.001) and to the mesentery (P<0.001) and artifacts (P<0.001), leading to a significant better overall image quality (P<0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P<0.001) and wall to lumen delineation (P<0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population. (orig.)

  2. A prospective randomized comparison between two MRI studies of the small bowel in Crohn's disease, the oral contrast method and MR enteroclysis

    International Nuclear Information System (INIS)

    Negaard, Anne; Paulsen, Vemund; Lygren, Idar; Sandvik, Leiv; Berstad, Audun E.; Borthne, Arne; Try, Kirsti; Storaas, Tryggve; Klow, Nils-Einar

    2007-01-01

    The aim was to compare bowel distension and diagnostic properties of magnetic resonance imaging of the small bowel with oral contrast (MRI per OS) with magnetic resonance enteroclysis (MRE). Forty patients with suspected Crohn's disease (CD) were examined with both MRI methods. MRI per OS was performed with a 6% mannitol solution and MRE with nasojejunal intubation and a polyethylenglycol solution. MRI protocol consisted of balanced fast field echo (B-FFE), T2 and T1 sequences with and without gadolinium. Two experienced radiologists individually evaluated bowel distension and pathological findings including wall thickness (BWT), contrast enhancement (BWE), ulcer (BWU), stenosis (BWS) and edema (EDM). The diameter of the small bowel was smaller with MRI per OS than with MRE (difference jejunum: 0.55 cm, p < 0.001; ileum: 0.35 cm, p < 0.001, terminal ileum: 0.09 cm, p = 0.08). However, CD was diagnosed with high diagnostic accuracy (sensitivity, specificity, positive and negative predictive values: MRI per OS 88%, 89%, 89%, 89%; MRE 88%, 84%, 82%, 89%) and inter-observer agreement (MRI per OS k = 0.95; MRE k = 1). In conclusion, bowel distension was inferior in MRI per OS compared to MRE. However, both methods diagnosed CD with a high diagnostic accuracy and reproducibility. (orig.)

  3. Evaluation of oral abdominal contrast agent containing ferric ammonium citrate

    International Nuclear Information System (INIS)

    Shiga, Toshiko; Kawamura, Yasutaka; Iwasaki, Toshiko

    1991-01-01

    We evaluated the effectiveness of oral MRI contrast agent containing ferric ammonium citrate. Twenty patients were arbitrarily divided into 2 groups according to the given dose of 100 and 200 mg Fe of oral MRI contrast agent. MRI was performed before and immediately after ingesting 300 ml solution of oral MRI contrast agent using a 1.5 T superconducting system (GE: Signa). Each dose of 100 and 200 mg Fe of oral MRI contrast agent produced sufficient enhancement of gastrointestinal tract, enough to make clear the pancreatic contour and porta hepatis. There was no significant change in blood and urine analysis observed after taking oral MRI contrast agent. The use of ferric ammonium citrate as an oral MRI contrast agent seems to add valuable information in performing upper abdominal MRI imaging. (author)

  4. Comparison of Water, Mannitol and Positive Oral Contrast for Evaluation of Bowel By Computed Tomography

    Directory of Open Access Journals (Sweden)

    Padhmanaban Elamparidhi

    2017-10-01

    Full Text Available Introduction: Small bowel remains a challenging anatomical site. Imaging approaches like CT-enterography helps in diagnosing non specific clinical presentations and imaging aids in appropriate management. Hence, bowel evaluation by CT requires a oral contrast agent for diagnosing the bowel pathology. Thus, quantitative and qualitative analysis of three oral contrast agents i.e., water, mannitol and positive contrast was done for identification of ideal intraluminal contrast agent. Aim: To assess the performance of mannitol as an endoluminal contrast agent as compared to water and positive contrast in the evaluation of bowel, to compare the distention of bowel with different oral contrasts and also to assess the usefulness of bowel distension in assessment of mural enhancement pattern of bowel. Materials and Methods: A comparative observational study was performed which consisted of 75 patients who were divided into three groups of 25 patients each. Patients in each group were given 1500 ml of oral contrast. Group I was given mannitol, Group II was given water and Group III was given positive contrast. Assessments of bowel distention at various levels and mural enhancement of bowel were studied. Chisquare test was used as test of significance for qualitative data. ANOVA (Analysis of Variance was the test of significance for quantitative data. Results: Bowel distention was excellent in mannitol compared to water and positive contrast. Wall enhancement and mural pattern was better appreciated with mannitol compared to other two contrast agents. Conclusion: Adequate bowel evaluation by CT requires an oral contrast agent which can cause maximal bowel distention, uniform intraluminal attenuation, increased contrast between intraluminal content and bowel wall with no artifacts and adverse effects. Mannitol has all the above characteristic and can be used as ideal neutral oral contrast agent.

  5. A comparison of the palatability of flavored oral contrasts.

    Science.gov (United States)

    Arya, Rajiv; Hansen, Allison; Taira, Breena R; Packy, Theodore; Singer, Adam J

    2009-09-01

    The aim of this study was to compare the taste of computed tomography (CT) oral contrast diluted with various flavored drinks. We performed a prospective, blinded, controlled trial in healthy adult volunteers. Subjects were assigned to ingest four 250-mL aliquots of oral contrast media diluted in water, Crystal Light Lemonade (Kraft Food, Northfield, Ill), Tropical Punch Kool-Aid (Kraft Food), and Tropicana orange juice (Pepsi Bottling Company, Sommers, NY) in random order; and the taste of the solution was measured with a 100-mm visual analogue scale and 5-point Likert scale from very worst to best. Between-group comparison of the taste scores was performed with repeated-measures analysis of variance and pairwise t tests. The study had 80% power to detect an effect size 0.75 SDs. There were 23 subjects; mean (SD) age was 33 (7.7) and 30% were female. The mean (SD) taste scores were water 12 (5), lemonade 37 (21), Kool-Aid 44 (20), and orange juice 40 (20) (P < .05). The proportion of subjects completely ingesting the contrast in water (65%) was significantly less than that with other 3 study solutions (100% each, P < .001). Dilution of oral contrast media with lemonade, fruit punch, or orange juice is tastier than with water. The choice of the specific juice used to dilute the oral contrast should be individualized based on patient preferences and availability.

  6. Usefulness of low dose oral contrast media in 18F-FDG PET/CT

    International Nuclear Information System (INIS)

    An, Young Sil; Yoon, Joon Kee; Hong, Seon Pyo; Joh, Chul Woo; Yoon, Seok Nam

    2006-01-01

    The standard protocol using large volume of oral contrast media may cause gastrointestinal discomfort and contrast-related artifacts in PET/CT. The aim of this study was to evaluate the usefulness of low dose oral contrast in 18 F-FDG PET/CT. We retrospectively reviewed the whole-body PET/CT images in a total of 435 patients. About 200 ml of oral contrast agent (barium sulfate) was administered immediately before injection of 18 F-FDG. The FDG uptake of intestines was analyzed by visual and semi-quantitative method on transaxial, coronal and saggital planes. Seventy (16%, 113 sites) of 435 images showed high FDG uptake (peak SUV > 4); 50 (74%, 84 sites) with diffuse and 20 (26%, 29 sites) with focal uptake. The most commonly delivered site of oral contrast media was small bowel (n = 27, 39%). On PET/CT images, FDG uptake coexisted with oral contrast media in 26 patients (54%, 38 sites) with diffuse pattern and 9 (45%, 9 sites) with focal pattern, and by sites, those were 38 (45%) and 9 (31%), respectively. In small bowel regions, the proportion of coexistence reached as high as 61% (29/47 sites). A visual analysis of available non-attenuation corrected PET images of 27 matched regions revealed no contrast-related artifact. We concluded that the application of low dose contrast media could be helpful in the evaluation of abdominal uptake in the FDG PET/CT image

  7. The primary applications of Gd-DTPA as an oral negative gastrointestinal contrast agent for MRCP

    International Nuclear Information System (INIS)

    Chen Yanping; Zhang Xuelin; Cheng Guanxun; Chang Renmin; Zhang Yuzhong; Cang Peng; Xia Qiong

    2003-01-01

    Objective: Using oral Gd-DTPA as a negative contrast agent to null the bowel signal during MR cholangiopancreatography (MRCP) to improve the quality of MRCP. Methods: A phantom study was performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in MRCP. 15 patients suspected of biliary tract and pancreatic disease were performed with MRCP before and after using 250 ml oral contrast agents (1:5 diluted Gd-DTPA, 1.488 g/L). All MR images were acquired using a 1.5 T whole body MR scanner (Vision Plus, Siemens). MRCP was acquired using two-dimensional single slice fast spin-echo sequence and HASTE (half-fourier acquisition single-shot fast spin echo) sequence. Results: The phantom study showed that the dilution ratio 1:5 of Gd-DTPA oral contrast agent was best in decreasing the signal intensity both in T 2 WI (59.3%) and in HASTE sequence (82.45%). All the dilution ratio of Gd-DTPA oral contrast agent decreased the signal intensity up to 90% on single slice MRCP. In all the patients the high signal intensity from the stomach and intestinal fluid was completely suppressed. The depictions of common bile duct and pancreatic duct were markedly improved by the oral contrast agent (P<0.05). Conclusion: 1:5 diluted (1.488 g/L) oral MR contrast agent Gd-DTPA can be an effective and safe negative contrast agent in eliminating signal intensity of the gastrointestinal tract, thus improving the depiction of the biliary system in MRCP

  8. Usefulness of low dose oral contrast media in FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    An, Y. S.; Yun, J. G.; Lee, M. H.; Cho, C. W.; Yun, S. N [Ajou University Medical Center, Suwon (Korea, Republic of)

    2004-07-01

    Oral contrast media might help in interpreting PET/CT images, allowing better discrimination between physiologic and pathologic abdominal uptake. The aim of this study was to evaluate the usefulness of low dose oral contrast on FDG PET/CT. A total of 435 cancer patients received 200mL of oral Barium with water(200mL) immediately before FDG injection. PET images were reconstructed using attenuation correction and iterative reconstruction. The FDG uptake in gastrointestinal(GI) tract were analyzed by visual and semiquantitative method in transaxial, coronal and sagittal planes. Seventy patients(16%, 113 sites) of 435 images showed high FDG uptake(pSUV>4.0) : 50(74%, 84 sites) with diffuse uptake and 20(26%, 29sites) with focal uptake. The most common distribution site of oral contrast media was small bowel (n=27, 39%) and others were small bowel with transverse colon(n=6, 8%), small bowel with ascending and sigmoid colon(n=6, 8%) and etc. In PET/CT images, FDG uptake coexisted with oral contrast was showed in 26 patients(54%) with diffuse pattern and 9(45%) with focal pattern, and by sites, those were 38(45%) and 9(31%), respectively. In small bowel regions, the most common distribution site, the proportion of coexistence reached as high as 61% (29 in the total 47 sites). Application of low dose contrast agent can be helpful in the evaluation of intestinal uptake in FDG PET/CT image.

  9. Usefulness of low dose oral contrast media in FDG PET/CT

    International Nuclear Information System (INIS)

    An, Y. S.; Yun, J. G.; Lee, M. H.; Cho, C. W.; Yun, S. N

    2004-01-01

    Oral contrast media might help in interpreting PET/CT images, allowing better discrimination between physiologic and pathologic abdominal uptake. The aim of this study was to evaluate the usefulness of low dose oral contrast on FDG PET/CT. A total of 435 cancer patients received 200mL of oral Barium with water(200mL) immediately before FDG injection. PET images were reconstructed using attenuation correction and iterative reconstruction. The FDG uptake in gastrointestinal(GI) tract were analyzed by visual and semiquantitative method in transaxial, coronal and sagittal planes. Seventy patients(16%, 113 sites) of 435 images showed high FDG uptake(pSUV>4.0) : 50(74%, 84 sites) with diffuse uptake and 20(26%, 29sites) with focal uptake. The most common distribution site of oral contrast media was small bowel (n=27, 39%) and others were small bowel with transverse colon(n=6, 8%), small bowel with ascending and sigmoid colon(n=6, 8%) and etc. In PET/CT images, FDG uptake coexisted with oral contrast was showed in 26 patients(54%) with diffuse pattern and 9(45%) with focal pattern, and by sites, those were 38(45%) and 9(31%), respectively. In small bowel regions, the most common distribution site, the proportion of coexistence reached as high as 61% (29 in the total 47 sites). Application of low dose contrast agent can be helpful in the evaluation of intestinal uptake in FDG PET/CT image

  10. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, K.; Reinprecht, P. [Roentgendiagnostisches Zentralinstitut, LKH Klagenfurt (Austria); Kau, T. [Roentgendiagnostisches Zentral Inst., Klagenfurt (Austria); Igerc, I.; Lind, P. [Abt. fuer Nuklearmedizin und Spezielle Endokrinologie, LKH Klagenfurt (Austria)

    2005-06-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk {sup registered}, which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk {sup registered} can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  11. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    International Nuclear Information System (INIS)

    Hausegger, K.; Reinprecht, P.; Kau, T.; Igerc, I.; Lind, P.

    2005-01-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk registered , which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk registered can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  12. Bioadhesive agents in addition to oral contrast media - evaluation in an animal model

    International Nuclear Information System (INIS)

    Conrad, R.; Schneider, G.; Textor, J.; Schild, H.H.; Fimmers, R.

    1998-01-01

    Purpose: To evaluate the additional effect of bioadhesives in combination with iotrolan and barium as oral contrast media in an animal model. Method: The bioadhesives Noveon, CMC, Tylose and Carbopol 934 were added to iotrolan and barium. The solutions were administered to rabbits by a feeding tube. The animals were investigated by computed tomography (CT) and radiography after 0,5, 4, 12, 24 and in part after 48 hours. Mucosal coating and contrast filling of the bowel were evaluated. Results: Addition of bioadhesives to oral contrast media effected long-term contrast in the small intestine and colon, but no improvement in continuous filling and coating of the gastrointestinal tract was detected. Mucosal coating was seen only in short regions of the caecum and small intestine. In CT the best results for coating were observed with tylose and CMC, in radiography additionally with carbopol and noveon. All contrast medium solutions were well tolerated. Conclusion: The evaluated contrast medium solutions with bioadhesives have shown long-term contrast but no improvement in coating in comparison to conventional oral contrast media. (orig.) [de

  13. The effect of palatability of oral contrast media on compliance with drinking protocols, and on bowel opacification, in abdominal CT

    International Nuclear Information System (INIS)

    Morgan, Bruno; Basu, Avi; Kithoray, Surjinder; Tyagi, Raman; Campbell, Shona; Liddicoat, Amanda

    2009-01-01

    Purpose: To assess whether palatability of oral contrast in CT has an impact on adherence to oral contrast media drinking protocols; and whether such variation has an impact on bowel opacification. Three different types of contrast media were compared; ionic and non-ionic iodinated oral contrast (Gastrografin, Diatrizoate, Schering AG), Gastromiro (Iopamidol, Bracco SpA) and the barium based contrast E-Z-Cat (E-Z-EM). Materials and methods: In the first stage of the study 101 prospective patients were randomly given 1 L of a ∼2% solution of Gastrografin or Gastromiro prior to a body CT scan. Data was recorded concerning the palatability of the oral contrast, drinking protocol compliance and bowel opacification. The second stage involved 66 prospective patients given Gastromiro or E-Z-Cat (again 1 L of ∼2% solution). Results: Gastromiro had better palatability than Gastrografin (p = 0.001) and improved protocol compliance. E-Z-Cat had similar palatability to Gastromiro . Patients who found the oral contrast more palatable had improved drinking protocol compliance (p = 0.007) and improved small bowel opacification (p = 0.03). E-Z-Cat had similar palatability and protocol compliance to Gastromiro but better overall small bowel opacification (p = 0.001). Conclusion: In conclusion we suggest that the palatability of oral contrast is not only important to the patients overall experience of body CT, but that it is also linked to adherence with oral contrast drinking protocols leading to better bowel opacification.

  14. Neutral vs positive oral contrast in diagnosing acute appendicitis with contrast-enhanced CT: sensitivity, specificity, reader confidence and interpretation time

    Science.gov (United States)

    Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F

    2011-01-01

    Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365

  15. Cine Magnetic Resonance Imaging of the Small Bowel: Comparison of Different Oral Contrast Media

    International Nuclear Information System (INIS)

    Asbach, P.; Breitwieser, C.; Diederichs, G.; Eisele, S.; Kivelitz, D.; Taupitz, M.; Zeitz, M.; Hamm, B.; Klessen, C.

    2006-01-01

    Purpose: To evaluate several substances regarding small bowel distension and contrast on balanced steady-state free precession (bSSFP) cine magnetic resonance (MR) images. Material and Methods: Luminal contrast was evaluated in 24 volunteers after oral application of two different contrast agent groups leading to either bright lumen (pineapple, blueberry juice) or dark lumen (tap water, orange juice) on T1-weighted images. Bowel distension was evaluated in 30 patients ingesting either methylcellulose or mannitol solution for limiting intestinal absorption. Fifteen patients with duodeno-jejunal intubation served as the control. Quantitative evaluation included measurement of luminal signal intensities and diameters of four bowel segments, qualitative evaluation assessed luminal contrast and distension on a five-point scale. Results: Quantitative and qualitative evaluation of the four contrast agents revealed no significant differences regarding luminal contrast on bSSFP images. Quantitative evaluation revealed significantly lower (P<0.05) small bowel distension for three out of four segments (qualitative evaluation: two out of four segments) for methylcellulose in comparison to the control. Mannitol was found to be equal to the control. Conclusion: Oral ingestion of tap water or orange juice in combination with mannitol is recommended for cine MR imaging of the small bowel regarding luminal contrast and small bowel distension on bSSFP sequences

  16. Cine Magnetic Resonance Imaging of the Small Bowel: Comparison of Different Oral Contrast Media

    Energy Technology Data Exchange (ETDEWEB)

    Asbach, P.; Breitwieser, C.; Diederichs, G.; Eisele, S.; Kivelitz, D.; Taupitz, M.; Zeitz, M.; Hamm, B.; Klessen, C. [Charite - Universitatsmedizin Berlin, Charite Campus Mitte, Berlin (Germany). Dept. of Radiology

    2006-11-15

    Purpose: To evaluate several substances regarding small bowel distension and contrast on balanced steady-state free precession (bSSFP) cine magnetic resonance (MR) images. Material and Methods: Luminal contrast was evaluated in 24 volunteers after oral application of two different contrast agent groups leading to either bright lumen (pineapple, blueberry juice) or dark lumen (tap water, orange juice) on T1-weighted images. Bowel distension was evaluated in 30 patients ingesting either methylcellulose or mannitol solution for limiting intestinal absorption. Fifteen patients with duodeno-jejunal intubation served as the control. Quantitative evaluation included measurement of luminal signal intensities and diameters of four bowel segments, qualitative evaluation assessed luminal contrast and distension on a five-point scale. Results: Quantitative and qualitative evaluation of the four contrast agents revealed no significant differences regarding luminal contrast on bSSFP images. Quantitative evaluation revealed significantly lower (P<0.05) small bowel distension for three out of four segments (qualitative evaluation: two out of four segments) for methylcellulose in comparison to the control. Mannitol was found to be equal to the control. Conclusion: Oral ingestion of tap water or orange juice in combination with mannitol is recommended for cine MR imaging of the small bowel regarding luminal contrast and small bowel distension on bSSFP sequences.

  17. An Improved Image Contrast Assessment Method

    Directory of Open Access Journals (Sweden)

    Yuanyuan Fan

    2013-07-01

    Full Text Available Contrast is an important factor affecting the image quality. In order to overcome the problems of local band-limited contrast, a novel image contrast assessment method based on the property of HVS is proposed. Firstly, the image by low-pass filter is performed fast wavelet decomposition. Secondly, all levels of band-pass filtered image and its corresponding low-pass filtered image are obtained by processing wavelet coefficients. Thirdly, local band-limited contrast is calculated, and the local band-limited contrast entropy is calculated according to the definition of entropy, Finally, the contrast entropy of image is obtained by averaging the local band-limited contrast entropy weighed using CSF coefficient. The experiment results show that the best contrast image can be accurately identified in the sequence images obtained by adjusting the exposure time and stretching gray respectively, the assessment results accord with human visual characteristics and make up the lack of local band-limited contrast.

  18. A method for the investigation of cholegraphic contrast media

    International Nuclear Information System (INIS)

    Otto, H.

    1982-01-01

    Isolated perfused rat livers were used for investigating possible interactions between two simultaneously injected contrast media, and which technique, using parenteral application of cholegraphic media, is optimal. The results show that excretion of a parenteral contrast medium is reduced by giving an oral contrast medium at the same time. Simultaneous administration of two different contrast media therefore does not result in improved diagnostic information. The effect depends on the dose, and a sufficiently long interval should be observed between giving an oral and a parenteral contrast medium. A comparison of excretion values following injection of a bolus and prolonged infusion shows higher biliary contrast concentration and increased excretion after a single injection. Comparing only the period after the infusion, no difference was found between these two methods of administration. The single injection offers pharmacokinetic advantages, but an infusion is better tolerated and has fewer side effects. A rapid infusion of 10 to 15 minutes is therefore recommended as the optimal means of administration. (orig.) [de

  19. Positive intraluminal bowel contrast on computed tomography following oral ingestion of Kayexelate

    International Nuclear Information System (INIS)

    Zissin, R.; Stackievicz, R.; Osadchy, A.; Gayer, G.

    2008-01-01

    Our study presents the computed tomography (CT) manifestations of orally ingested kayexelate (a powdered form of sodium polystyrene sulphonate) used to treat hyperkalemia. Five patients with whom kayexelate appeared as high-attenuating intraluminal enteric content, similar to oral contrast material or leakage of intravascular contrast, are reported. Radiologists should be familiar with its appearance as it may mimic oral or vascular contrast within the gastrointestinal tract, a finding that may lead to a diagnostic error or misinterpretation. (author)

  20. Computed tomography enterography: a comparison of different neutral oral contrast agents

    International Nuclear Information System (INIS)

    D'Ippolito, Giuseppe; Braga, Fernanda Angeli; Resende, Marcelo Cardoso; Bretas, Elisa Almeida Sathler; Nunes, Thiago Franchi; Rosas, George de Queiroz; Tiferes, Dario Arie

    2012-01-01

    Objective: The purpose of this study was to assess the performance of neutral oral contrast agents, comparing intestinal distension, distinction of intestinal wall, acceptance and side effects. Materials and Methods: Prospective, randomized, and double-blinded study involving 30 patients who underwent computed tomography of abdomen and pelvis with administration of neutral oral contrast agents, divided into three groups according the contrast agent type: milk, water, and polyethylene glycol. The images were consensually analyzed by two observers, considering the degree of bowel distension and intestinal wall distinction. The patients responded to a questionnaire regarding the taste of the ingested solution and on their side effects. Kruskal-Wallis and chi-square tests were employed for statistical analysis. Results: Among 40 studied intestinal segments, appropriate bowel distension (intestinal loop diameter > 2 cm) was observed in 14 segments (35%) in the milk group, 10 segments (25%) in the water group and 23 segments (57%) in the polyethylene glycol group (p = 0.01). Preparation with polyethylene glycol resulted in the best bowel distension, but it presented the worst taste and highest incidence of diarrhea as reported by patients. Conclusion: Bowel preparation with oral polyethylene glycol results in higher degree of bowel distension than with water or milk, but presents worst acceptance related to its taste and frequency of diarrhea as a side effect. (author)

  1. Computed tomography enterography: a comparison of different neutral oral contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Department of Imaging Diagnosis, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Braga, Fernanda Angeli; Resende, Marcelo Cardoso; Bretas, Elisa Almeida Sathler; Nunes, Thiago Franchi; Rosas, George de Queiroz; Tiferes, Dario Arie [Abdominal Imaging Section, Department of Imaging Diagnosis - Universidade Federal de Sao Paulo (Unifesp), Sao Paulo, SP (Brazil)

    2012-05-15

    Objective: The purpose of this study was to assess the performance of neutral oral contrast agents, comparing intestinal distension, distinction of intestinal wall, acceptance and side effects. Materials and Methods: Prospective, randomized, and double-blinded study involving 30 patients who underwent computed tomography of abdomen and pelvis with administration of neutral oral contrast agents, divided into three groups according the contrast agent type: milk, water, and polyethylene glycol. The images were consensually analyzed by two observers, considering the degree of bowel distension and intestinal wall distinction. The patients responded to a questionnaire regarding the taste of the ingested solution and on their side effects. Kruskal-Wallis and chi-square tests were employed for statistical analysis. Results: Among 40 studied intestinal segments, appropriate bowel distension (intestinal loop diameter > 2 cm) was observed in 14 segments (35%) in the milk group, 10 segments (25%) in the water group and 23 segments (57%) in the polyethylene glycol group (p = 0.01). Preparation with polyethylene glycol resulted in the best bowel distension, but it presented the worst taste and highest incidence of diarrhea as reported by patients. Conclusion: Bowel preparation with oral polyethylene glycol results in higher degree of bowel distension than with water or milk, but presents worst acceptance related to its taste and frequency of diarrhea as a side effect. (author)

  2. 10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography

    International Nuclear Information System (INIS)

    Choi, Sun Kyou; Chon, Dong Kwon; Han, Young Min; Kim, Chong Soo; Sohn, Myung Hee; Song, Ho Young; Choi, Ki Chul

    1990-01-01

    CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast agent. 3. The discrimination between pancreatic head from duodenal C-loop is better in patients receiving 10% COE than in patients receiving conventional oral contrast agent. 4. In patients receiving 10% COE, differentiation of cystic masses from intestinal loops is sometimes difficult. The results of this study indicate that 10% COE may be useful oral contrast agent for optimal visualization of gastric mucosa and pancreatico-duodenal discrimination on abdominal CT

  3. Oral water soluble contrast for malignant bowel obstruction.

    Science.gov (United States)

    Syrmis, William; Richard, Russell; Jenkins-Marsh, Sue; Chia, Siew C; Good, Phillip

    2018-03-07

    Malignant bowel obstruction (MBO) is a common problem in patients with intra-abdominal cancer. Oral water soluble contrast (OWSC) has been shown to be useful in the management of adhesive small bowel obstruction in identifying patients who will recover with conservative management alone and also in reducing the length of hospital stay. It is not clear whether the benefits of OWSC in adhesive small bowel obstruction are also seen in patients with MBO. To determine the reliability of OWSC media and follow-up abdominal radiographs in predicting the success of conservative treatment in resolving inoperable MBO with conservative management.To determine the efficacy and safety of OWSC media in reducing the duration of obstruction and reducing hospital stay in people with MBO. We identified studies from searching Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and MEDLINE in Process, Embase, CINAHL, Science Citation Index (Web of Science) and Conference Proceedings Citation Index - Science (Web of Science). We also searched registries of clinical trials and the CareSearch Grey Literature database. The date of the search was the 6 June 2017. Randomised controlled trials (RCTs), or prospective controlled studies, that evaluated the diagnostic potential of OWSC in predicting which malignant bowel obstructions will resolve with conservative treatment.RCTs, or prospective controlled studies, that assessed the therapeutic potential of OWSC in managing MBO at any level compared with placebo, no intervention or usual treatment or supportive care. We used standard methodological procedures expected by Cochrane. We assessed risk of bias and assessed the evidence using GRADE and created a 'Summary of findings' table. We found only one RCT meeting the selection criteria for the second objective (therapeutic potential) of this review. This study recruited nine participants. It compared the use of gastrografin versus placebo in adult patients with MBO with no

  4. The use of dilute calogen[reg] as a fat density oral contrast medium in upper abdominal computed tomography, compared with the use of water and positive oral contrast media

    International Nuclear Information System (INIS)

    Ramsay, Duncan W.; Markham, Derrian H.; Morgan, Bruno; Rodgers, Peter M.; Liddicoat, Amanda J.

    2001-01-01

    AIM: Oral contrast media are commonly given prior to computed tomography (CT) examination of the upper abdomen. Although positive oral contrast media are normally used, there is increasing interest in using negative agents such as water and less commonly fat density products. The aim of this study was to compare a positive oral contrast medium, water, and a diluted emulsion of arachis oil (Calogen[reg], a fat density food supplement) for assessment of the upper abdomen. MATERIALS AND METHODS: Seventy-one patients referred for upper abdominal CT were randomized to receive either 500 ml water, 2% sodium diatrizoate or a dilute suspension of Calogen[reg]. The CT images were scored independently by three radiologists. Distension and anatomical identification was assessed for the stomach, duodenum and jejunum; with anatomical identification recorded for the pancreas, retroperitoneum, liver, gallbladder and spleen. RESULTS: Dilute Calogen[reg] produced a significant improvement (P < 0.01) in distension and anatomical visualization of the stomach and proximal duodenum. Only minimal differences were demonstrated between the three contrast media for visualization of more distal small bowel or identification of the other upper abdominal viscera. Significantly more artifacts were caused by positive contrast media than with the Calogen[reg] mixture. CONCLUSION: A dilute suspension of Calogen[reg] as an oral contrast medium is recommended when disease is suspected within the stomach or proximal duodenum. Ramsay, D.W. et al. (2001)

  5. The comparative study of various oral contrast media in 3D display of gastric lesions in spiral CT

    International Nuclear Information System (INIS)

    Wu Dong; Zhou Kangrong; Peng Weijun

    2001-01-01

    Objective: To optimize the oral contrast media in three-dimensional display of gastric lesions. Methods: 41 cases were randomly divided into 3 groups according to different oral contrast media administered: No. 1 air contrast group (n = 17), No. 2 fat emulsion group (n = 7) and No. 3 positive contrast group (n = 25). The 3D CT images were reconstructed using MPR, SSD, RaySum display and virtual endoscopic techniques, and compared with gastric endoscopy and/or conventional barium study. Results: The detectability of gastric lesions using fat emulsion and air contrast was 42.8%(3/7) and 80.0%(20/25), respectively, both were significantly lower than that using positive contrast (100%, 30/30) (x 2 = 19.22, P 2 = 6.60, P 2 = 17.04, P < 0.01). Conclusion: It is very important to choose the appropriate oral contrast media for 3D display of gastric lesions in spiral CT, the positive contrast agent is the optimal choice

  6. Oral gadopentetate dimeglumine administration as a negative gastrointestinal contrast agent to improve image quality of MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Chen Yi; Xu Yikai; Zhao Yuhui; Wang Guisheng

    2008-01-01

    Objective: To choose optimal concentration and volume of Gd-DTPA solution as a oral gastrointestinal negative contrast agent for MRCP. To evaluate the role of Gd-DTPA solution in improving image quality of MRCP. Methods: In vitro experiment: Gd-DTPA solution was made with different concentrations. T 1 WI, T 2 WI, two-dimensional single slice fast spin echo sequence and three-dimensional half-fourier acquisition single-shot fast spin echo sequence were performed to measure the signal intensity of these contrast agents respectively, so Gd-DTPA solution with the optimal concentration can be decided as oral negative gastrointestinal contrast agent on MRCP. Clinical study: The Gd-DTPA solution with optimal concentration and volume was regarded as an oral negative gastrointestinal contrast agent of MRCP. Twenty- four' patients were performed with MRCP before and after (5-10 minutes and 10-15 minutes) administration of oral negative gastrointestinal contrast agent and image quality was analyzed. Statistical analysis was performed using analysis of variance with SPSS 10.0. Results: When the concentration of Gd-DTPA solution was ≤0.01 mol/L, the contrast agent was hyperintense on T 1 WI. On T 2 WI, when the concentration was ≥0.015 mol/L, it was as hypointense as basic ground; On 2D FSE MRCP images, controls were hyperintense and the contrast agent with concentration ranging from 0.0025 mol/L to 0.03 mol/L was hypointense. On 3D HEAST MRCP image, controls were hyperintense and when the concentration of Gd-DTPA was ≥0.01 mol, the contrast agent was hypointense. The Gd-DTPA solution with the concentration of 0.01 mol/L and the volume of 100 ml was chosen as MRCP oral negative gastrointestinal contrast agent. On MRCP images after oral administration of the contrast agent, in 10-15 minutes, the average grade scores within 24 patients of the intrahepatic bile duct, the common hepatic bile duct, the gall bladder, the common bile duct and pancreatic duct (the average grade

  7. In vitro evaluation of alternative oral contrast agents for MRI of the gastrointestinal tract

    Energy Technology Data Exchange (ETDEWEB)

    Babos, Magor [University of Szeged, Faculty of Science (Hungary); Euromedic Diagnostics Szeged, 6720 Szeged, Semmelweiss u. 6 (Hungary)], E-mail: babosmagor@yahoo.com; Schwarcz, Attila [University of Pecs, Department of Neurosurgery, Pecs Diagnostic Institute, 7624 Pecs, Retu. 2 (Hungary)], E-mail: attila.schwarcz@aok.pte.hu; Randhawa, Manjit Singh [University of Szeged, Faculty of Medicine, Department of Radiology, 6720 Szeged, Semmelweiss u. 6 (Hungary)], E-mail: majyaal@hotmail.com; Marton, Balazs [University of Szeged, Faculty of Medicine, Department of Radiology, 6720 Szeged, Semmelweiss u. 6 (Hungary)], E-mail: balazsmarton@freemail.hu; Kardos, Lilla [Euromedic Diagnostics Szeged, 6720 Szeged, Semmelweiss u. 6 (Hungary)], E-mail: medlis@tiszanet.hu; Palko, Andras [Euromedic Diagnostics Szeged, 6720 Szeged, Semmelweiss u. 6 (Hungary); University of Szeged, Faculty of Medicine, Department of Radiology, 6720 Szeged, Semmelweiss u. 6 (Hungary)], E-mail: palko@radio.szote.u-szeged.hu

    2008-01-15

    Purpose: In vitro evaluation of different materials as potential alternative oral contrast agents for small bowel MRI. Materials and methods: The T1 and T2 relaxation times of rose hip syrup, black currant extract, cocoa, iron-deferoxamine solution and a commonly used oral contrast material (1 mM Gd-DTPA) were determined in vitro at different concentrations on a 1.0 T clinical MR scanner. T1 values were obtained with an inversion prepared spoiled gradient echo sequence. T2 values were obtained using multiple echo sequences. Finally the materials were visualized on T1-, T2- and T2*-weighted MR images. Results: The relaxation times of the undiluted rose hip syrup (T1 = 110 {+-} 5 ms, T2 = 86 {+-} 3 ms), black currant extract (T1 = 55 {+-} 3 ms, T2 = 39 {+-} 2 ms) and 5 mM iron-deferoxamine solution (T1 = 104 {+-} 4 ms, T2 = 87 {+-} 2 ms) were much shorter than for a 1 mM Gd-DTPA solution (T1 = 180 {+-} 8 ms, T2 = 168 {+-} 5 ms). Dilution of black currant extract to 30% or a 3 mM iron-deferoxamine solution conducted to T1 relaxation times which are quite comparable to a 1 mM Gd-DTPA solution. Despite its much lower metal content an aqueous cocoa suspension (100 g/L) produced T2 relaxation times (T1 = 360 {+-} 21 ms, T2 = 81 {+-} 3 ms) more or less in the same range like the 5 mM iron-deferoxamine solution. Imaging of our in vitro model using clinical sequences allowed to anticipate the T1-, T2- and T2*-depiction of all used substances. Cocoa differed from all other materials with its low to moderate signal intensity on T1- and T2-weighted sequences. While all substances presented a linear 1/T1 and 1/T2 relationship towards concentration, rose hip syrup broke ranks with a disproportionately high increase of relaxation at higher concentrations. Conclusions: Rose hip syrup, black currant extract and iron-deferoxamine solution due to their positive T1 enhancement characteristics and drinkability appear to be valuable oral contrast agents for T1-weighted small bowel MRI

  8. In vitro evaluation of alternative oral contrast agents for MRI of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Babos, Magor; Schwarcz, Attila; Randhawa, Manjit Singh; Marton, Balazs; Kardos, Lilla; Palko, Andras

    2008-01-01

    Purpose: In vitro evaluation of different materials as potential alternative oral contrast agents for small bowel MRI. Materials and methods: The T1 and T2 relaxation times of rose hip syrup, black currant extract, cocoa, iron-deferoxamine solution and a commonly used oral contrast material (1 mM Gd-DTPA) were determined in vitro at different concentrations on a 1.0 T clinical MR scanner. T1 values were obtained with an inversion prepared spoiled gradient echo sequence. T2 values were obtained using multiple echo sequences. Finally the materials were visualized on T1-, T2- and T2*-weighted MR images. Results: The relaxation times of the undiluted rose hip syrup (T1 = 110 ± 5 ms, T2 = 86 ± 3 ms), black currant extract (T1 = 55 ± 3 ms, T2 = 39 ± 2 ms) and 5 mM iron-deferoxamine solution (T1 = 104 ± 4 ms, T2 = 87 ± 2 ms) were much shorter than for a 1 mM Gd-DTPA solution (T1 = 180 ± 8 ms, T2 = 168 ± 5 ms). Dilution of black currant extract to 30% or a 3 mM iron-deferoxamine solution conducted to T1 relaxation times which are quite comparable to a 1 mM Gd-DTPA solution. Despite its much lower metal content an aqueous cocoa suspension (100 g/L) produced T2 relaxation times (T1 = 360 ± 21 ms, T2 = 81 ± 3 ms) more or less in the same range like the 5 mM iron-deferoxamine solution. Imaging of our in vitro model using clinical sequences allowed to anticipate the T1-, T2- and T2*-depiction of all used substances. Cocoa differed from all other materials with its low to moderate signal intensity on T1- and T2-weighted sequences. While all substances presented a linear 1/T1 and 1/T2 relationship towards concentration, rose hip syrup broke ranks with a disproportionately high increase of relaxation at higher concentrations. Conclusions: Rose hip syrup, black currant extract and iron-deferoxamine solution due to their positive T1 enhancement characteristics and drinkability appear to be valuable oral contrast agents for T1-weighted small bowel MRI. Cocoa with its

  9. Comparison of Oral Contrast-Enhanced Transabdominal Ultrasound Imaging With Transverse Contrast-Enhanced Computed Tomography in Preoperative Tumor Staging of Advanced Gastric Carcinoma.

    Science.gov (United States)

    He, Xuemei; Sun, Jing; Huang, Xiaoling; Zeng, Chun; Ge, Yinggang; Zhang, Jun; Wu, Jingxian

    2017-12-01

    This study assessed the diagnostic performance of transabdominal oral contrast-enhanced ultrasound (US) imaging for preoperative tumor staging of advanced gastric carcinoma by comparing it with transverse contrast-enhanced computed tomography (CT). This retrospective study included 42 patients with advanced gastric cancer who underwent laparoscopy, radical surgery, or palliative surgery because of serious complications and had a body mass index of less than 25 kg/m 2 . A cereal-based oral contrast agent was used for transabdominal oral contrast-enhanced US. Retrospective analyses were conducted using preoperative tumor staging data acquired by either transabdominal oral contrast-enhanced US or transverse contrast-enhanced CT. Both contrast-enhanced US and contrast-enhanced CT examinations were reviewed by 2 experienced radiologists independently for preoperative tumor staging according to the seventh edition of the TNM classification. The accuracy, sensitivity, and specificity were calculated by comparing the results of contrast-enhanced US and contrast-enhanced CT with pathologic findings. The overall accuracies of the imaging modalities were compared by the McNemar test. No significant difference was noted in the overall accuracy of transabdominal oral contrast-enhanced US (86% [36 of 42]) and transverse contrast-enhanced CT (83% [35 of 42] P > .999). For stage T2 to T4 gastric cancer, the accuracies of transabdominal oral contrast-enhanced US were 88%, 86%, and 98%, respectively, and those of transverse contrast-enhanced CT were 93%, 83%, and 90%. The overall accuracy of transabdominal oral contrast-enhanced US was comparable with that of transverse contrast-enhanced CT for preoperative tumor staging of advanced gastric cancer. © 2017 by the American Institute of Ultrasound in Medicine.

  10. Acceptability of oral iodinated contrast media: a head-to-head comparison of four media

    Science.gov (United States)

    Ngan-Soo, E; McCoubrie, P

    2013-01-01

    Objective: To assess the palatability of iodinated oral contrast media commonly used in abdominopelvic CT and CT colonography (CTC). Methods: 80 volunteers assessed the palatability of a 20-ml sample of a standard 30 mg ml−1 dilution of Omnipaque® (iohexol; GE Healthcare, Cork, Ireland), Telebrix® (meglumine ioxithalamate; Guerbet, Aulnay-sous-Bois, France), Gastromiro® (iopamidol; Bracco, High Wycombe, UK) and Gastrografin® (sodium diatrizoate and meglumine diatrizoate; Bayer, Newbury, UK) in a computer-generated random order. Results: Gastrografin is rated significantly less palatable than the remaining media (pcontrast media than both Gastromiro and Gastrografin, which has potential implications in compliance with both abdominopelvic CT and CTC. PMID:23564884

  11. Gadolinium-DTPA as an oral contrast medium for MR tomography of the abdomen

    International Nuclear Information System (INIS)

    Krahe, T.; Doelken, W.; Lackner, K.; Houselog, M.

    1990-01-01

    150 MR examinations of the upper abdomen were carried out after the oral administration of 5 ml/kg body weight of a gadolinium DTPA formulation (1.0 mmol/l, 15 g/l manitol), with reference to the delineation of the pancreas, the liver and intra-abdominal fat. For comparison, 100 MR examinations without oral opacification of the G.I. tract were evaluated. Contrast administration resulted in a signal-intensive demonstration of the G.I tract for all measurement sequences. The intraluminal contrast improved the distinction between normal and abnormal structures, T 1 and T 2 sequences and the demonstration of fat on T 2 -weighted series. T 1 -weighted series showed the best diagnostic results. In 25% there was meteorism and diarrhoea within 24 hours of the administration of the oral contrast. (orig.) [de

  12. Abdominal 64-MDCT for suspected appendicitis: the use of oral and IV contrast material versus IV contrast material only.

    Science.gov (United States)

    Anderson, Stephan W; Soto, Jorge A; Lucey, Brian C; Ozonoff, Al; Jordan, Jacqueline D; Ratevosian, Jirair; Ulrich, Andrew S; Rathlev, Niels K; Mitchell, Patricia M; Rebholz, Casey; Feldman, James A; Rhea, James T

    2009-11-01

    The objective of our study was to compare the diagnostic accuracy of IV contrast-enhanced 64-MDCT with and without the use of oral contrast material in diagnosing appendicitis in patients with abdominal pain. We conducted a randomized trial of a convenience sample of adult patients presenting to an urban academic emergency department with acute nontraumatic abdominal pain and clinical suspicion of appendicitis, diverticulitis, or small-bowel obstruction. Patients were enrolled between 8 am and 11 pm when research assistants were present. Consenting subjects were randomized into one of two groups: Group 1 subjects underwent 64-MDCT performed with oral and IV contrast media and group 2 subjects underwent 64-MDCT performed solely with IV contrast material. Three expert radiologists independently reviewed the CT examinations, evaluating for the presence of appendicitis. Each radiologist interpreted 202 examinations, ensuring that each examination was interpreted by two radiologists. Individual reader performance and a combined interpretation performance of the two readers assigned to each case were calculated. In cases of disagreement, the third reader was asked to deliver a tiebreaker interpretation to be used to calculate the combined reader performance. Final outcome was based on operative, clinical, and follow-up data. We compared radiologic diagnoses with clinical outcomes to calculate the diagnostic accuracy of CT in both groups. Of the 303 patients enrolled, 151 patients (50%) were randomized to group 1 and the remaining 152 (50%) were randomized to group 2. The combined reader performance for the diagnosis of appendicitis in group 1 was a sensitivity of 100% (95% CI, 76.8-100%) and specificity of 97.1% (95% CI, 92.7-99.2%). The performance in group 2 was a sensitivity of 100% (73.5-100%) and specificity of 97.1% (92.9-99.2%). Patients presenting with nontraumatic abdominal pain imaged using 64-MDCT with isotropic reformations had similar characteristics for the

  13. Oral contrast medium in PET/CT: should you or shouldn't you?

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Dickson, John C.; Townsend, Caroline; Croasdale, Ian; Syed, Rizwan; Nagabushan, Nagesh; Hain, Sharon F.; Ell, Peter J.; Bomanji, Jamshed B.

    2005-01-01

    It has been suggested that the use of computed tomography (CT) positive contrast agents has led to attenuation-induced artefacts on 18 F-fluorodeoxyglucose positron emission tomography ( 18 F-FDG PET/CT) systems. Consequently, centres may withhold the use of such agents. Whilst there is theoretical evidence to support the aforementioned claim, the clinical relevance of the induced artefacts has not been widely established. Moreover, the potential benefits of bowel enhancement on PET/CT have yet to be formally evaluated. We therefore prospectively examined PET/CT studies to assess whether the use of oral contrast medium induces clinically relevant artefacts and whether the use of these agents is diagnostically helpful. Over a 2-month period, 18 F-FDG PET/CT images were prospectively reviewed from 200 patients following Gastrografin administration 2 h prior to examination. Both a radiologist and a nuclear medicine physician reviewed the images for contrast medium-mediated clinically relevant artefacts. Artefacts were sought on the CT attenuation-corrected images and were compared with the appearance on non-attenuated-corrected images. The number of examinations in which the oral contrast aided image interpretation was also noted. There were no oral contrast medium-induced clinically significant artefacts. In 38 of the 200 patients, oral contrast aided image interpretation (owing to differentiation of mass/node from bowel, discrimination of intestinal wall from lumen or definition of the anatomy of a relevant site). In 33 of these 38 patients, the anatomical site of interest was the abdomen/pelvis. The use of oral contrast medium in 18 F-FDG PET studies should not be withheld as it improves image interpretation and does not produce clinically significant artefacts. (orig.)

  14. Reconstruction methods for phase-contrast tomography

    Energy Technology Data Exchange (ETDEWEB)

    Raven, C.

    1997-02-01

    Phase contrast imaging with coherent x-rays can be distinguished in outline imaging and holography, depending on the wavelength {lambda}, the object size d and the object-to-detector distance r. When r << d{sup 2}{lambda}, phase contrast occurs only in regions where the refractive index fastly changes, i.e. at interfaces and edges in the sample. With increasing object-to-detector distance we come in the area of holographic imaging. The image contrast outside the shadow region of the object is due to interference of the direct, undiffracted beam and a beam diffracted by the object, or, in terms of holography, the interference of a reference wave with the object wave. Both, outline imaging and holography, offer the possibility to obtain three dimensional information of the sample in conjunction with a tomographic technique. But the data treatment and the kind of information one can obtain from the reconstruction is different.

  15. Breakthrough reactions of iodinated and gadolinium contrast media after oral steroid premedication protocol.

    Science.gov (United States)

    Jingu, Akiko; Fukuda, Junya; Taketomi-Takahashi, Ayako; Tsushima, Yoshito

    2014-10-06

    Adverse reactions to iodinated and gadolinium contrast media are an important clinical issue. Although some guidelines have proposed oral steroid premedication protocols to prevent adverse reactions, some patients may have reactions to contrast media in spite of premedication (breakthrough reaction; BTR).The purpose of this study was to assess the frequency, type and severity of BTR when following an oral steroid premedication protocol. All iodinated and gadolinium contrast-enhanced radiologic examinations between August 2011 and February 2013 for which the premedication protocol was applied in our institution were assessed for BTRs. The protocol was applied to a total of 252 examinations (153 patients, ages 15-87 years; 63 males, 90 females). Of these, 152 were for prior acute adverse reactions to contrast media, 85 were for a history of bronchial asthma, and 15 were for other reasons. There were 198 contrast enhanced CTs and 54 contrast enhanced MRIs. There were nine BTR (4.5%) for iodinated contrast media, and only one BTR (1.9%) for gadolinium contrast media: eight were mild and one was moderate. No patient who had a mild index reaction (IR) had a severe BTR. Incidence of BTRs when following the premedication protocol was low. This study by no means proves the efficacy of premedication, but provides some support for following a premedication protocol to improve safety of contrast-enhanced examinations when prior adverse reactions are mild, or when there is a history of asthma.

  16. Breakthrough reactions of iodinated and gadolinium contrast media after oral steroid premedication protocol

    International Nuclear Information System (INIS)

    Jingu, Akiko; Fukuda, Junya; Taketomi-Takahashi, Ayako; Tsushima, Yoshito

    2014-01-01

    Adverse reactions to iodinated and gadolinium contrast media are an important clinical issue. Although some guidelines have proposed oral steroid premedication protocols to prevent adverse reactions, some patients may have reactions to contrast media in spite of premedication (breakthrough reaction; BTR). The purpose of this study was to assess the frequency, type and severity of BTR when following an oral steroid premedication protocol. All iodinated and gadolinium contrast-enhanced radiologic examinations between August 2011 and February 2013 for which the premedication protocol was applied in our institution were assessed for BTRs. The protocol was applied to a total of 252 examinations (153 patients, ages 15–87 years; 63 males, 90 females). Of these, 152 were for prior acute adverse reactions to contrast media, 85 were for a history of bronchial asthma, and 15 were for other reasons. There were 198 contrast enhanced CTs and 54 contrast enhanced MRIs. There were nine BTR (4.5%) for iodinated contrast media, and only one BTR (1.9%) for gadolinium contrast media: eight were mild and one was moderate. No patient who had a mild index reaction (IR) had a severe BTR. Incidence of BTRs when following the premedication protocol was low. This study by no means proves the efficacy of premedication, but provides some support for following a premedication protocol to improve safety of contrast-enhanced examinations when prior adverse reactions are mild, or when there is a history of asthma

  17. Comparison between two positive and one negative oral contrast medium for abdominal CT diagnosis

    International Nuclear Information System (INIS)

    Zwaan, M.; Gmelin, E.

    1989-01-01

    In a prospective randomised study three groups of 30 patients each were subjected to CT of the entire abdomen. The oral intestinal contrast media used were iodine solution (2%), barium suspension (1.5%) and paraffin emulsion (25%). The results were evaluated according to imaging, artifacts, assessability of the intestinal wall, taste and side effects. All three contrast media are suitable for marking the gastrointestinal tract; paraffin shows advantages in the upper part of the tract and is the only medium that enables assessment of the wall, while causing the lowest rate of artifacts. Barium has a high acceptance and the best tolerance of all contrast agents. (orig.) [de

  18. Barium sulfate suspension as a negative oral contrast agent for MR imaging

    International Nuclear Information System (INIS)

    Li, K.C.P.; Tart, R.P.; Fitzsimmons, J.R.; Storm, B.; Mao, J.

    1989-01-01

    Proton spectroscopy with linewidth measurements and MR imaging were performed on various commercially available barium sulfate suspensions as well as inorganic sulfates and barium salts. Approximately 500 mL of 20%, 40%, 60%, and 70% wt/wt single-contrast oral barium sulfate suspensions were administered to four normal volunteers, and MR imaging was performed with both a 1.5-T and a 0.15-T MR imager. As much as 80% of the small bowel and the entire colon were well visualized with the 60% or 70% wt/wt single-contrast barium sulfate suspensions. The authors conclude that barium sulfate suspensions are useful as oral MR contrast agents

  19. Minor salivary gland tumors in the oral cavity: Diagnostic value of dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Matsuzaki, Hidenobu; Yanagi, Yoshinobu; Hara, Marina; Katase, Naoki; Asaumi, Jun-ichi; Hisatomi, Miki; Unetsubo, Teruhisa; Konouchi, Hironobu; Takenobu, Toshihiko; Nagatsuka, Hitoshi

    2012-01-01

    Objective: To evaluate the diagnostic value of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for minor salivary gland tumors in the oral cavity. Materials and methods: Thirty-two patients with minor salivary gland tumors were examined preoperatively using DCE-MRI. Their maximum contrast index (CImax), time of CImax (Tmax), Tpeak; i.e., the time that corresponded to the CImax × 0.90, and washout ratios (WR300 and WR600) were determined from contrast index (CI) curves. We compared these parameters between benign and malignant tumors and among the different histopathological types of minor salivary gland tumors. Then, we categorized the patients’ CI curves into four patterns (gradual increase, rapid increase with high washout ratio, rapid increase with low washout, and flat). Results: Statistically significant differences in Tmax (P = 0.004) and Tpeak (P = 0.002) were observed between the benign and malignant tumors. Regarding each histopathological tumor type, significant differences in Tmax (P < 0.001), Tpeak (P < 0.001), and WR600 (P = 0.026) were observed between the pleomorphic adenomas and mucoepidermoid carcinomas. It was difficult to distinguish between benign and malignant tumors using our CI curve classification because that two-thirds of the cases were classified into the same type (gradual increase). Conclusion: The DCE-MRI parameters of minor salivary gland tumors contributed little to their differential diagnosis compared with those for major salivary gland tumors. During the diagnosis of minor salivary gland tumors, Tmax is useful for distinguishing between benign and malignant tumors

  20. Speechline - a method for teaching oral presentation

    DEFF Research Database (Denmark)

    Juel, Henrik

    2015-01-01

    The Speech-line method aims at improving the active rhetorical skills of students, i.e. their ability to present academic subjects in a clear and convincing manner. This is relevant not only for everyday classroom work, but also for oral exams, for presenting research projects, and for addressing...

  1. Interactive neonatal gastrointestinal magnetic resonance imaging using fruit juice as an oral contrast media

    International Nuclear Information System (INIS)

    Arthurs, Owen J; Graves, Martin J; Edwards, Andrea D; Joubert, Ilse; Set, Pat AK; Lomas, David J

    2014-01-01

    The objective was to evaluate the use of fruit juice with an interactive inversion recovery (IR) MR pulse sequence to visualise the gastrointestinal tract. We investigated the relaxation properties of 12 different natural fruit juices in vitro, to identify which could be used as oral contrast. We then describe our initial experience using an interactive MR pulse sequence to allow optimal visualisation after administering pineapple juice orally, and suppressing pre-existing bowel fluid contents, with variable TI in three adult and one child volunteer. Pineapple juice (PJ) had both the shortest T 1 (243 ms) and shortest T 2 (48 ms) of the fruit juices tested. Optimal signal differentiation between pre-existing bowel contents and oral PJ administration was obtained with TIs of between 900 and 1100 ms. The use of an inversion recovery preparation allowed long T 1 pre-existing bowel contents to be suppressed whilst the short T 1 of fruit juice acts as a positive contrast medium. Pineapple juice could be used as oral contrast agent for neonatal gastrointestinal magnetic resonance imaging

  2. Clinical application of multislice CT enterography with hypertonic mannitol saline as oral contrast

    International Nuclear Information System (INIS)

    Yan Guixin; Wang Haitao; Chen Wenjing; Liu Wenya

    2011-01-01

    Objective: To assess the feasibility and value of multislice CT enterography (MSCTE) with large dose economy and convenience orally administered hypertonic mannitol salt water (2.5% mannitol and 1.5% NaCl salt water) as negative contrast in demonstrating normal and abnormal small bowel. Methods: 81 patients suffered from digestive disease and suspected of various kinds of small intestinal diseases were examined (male/female=47/34, 26-81 years old, average 57.8 years). About 1500 ml∼3000 ml hypertonic mannitol saline was oral administered within 90 minutes and 20 mg of raceanisodamine hydrochloride injection was injected intramuscularly. CT scanning was performed 20 minutes later. Imaging data were post processed with coronal, sagittal and oblique reconstruction, multiplanar reformation (MPR), maximum intensity projection (MIP), and volumer rendering technique (VRT). The filling degree of stomach, intestine and colon was classified as satisfactory, better and unsatisfactory. The length and superposition of small intestine was classified as dense-type, uniformity-type and straggling-type. The maximum outer diameters of duodenum, jejunum, and ileum were measured respectively in different segments. The degree of bowel wall enhancement in arterial phase and venous phase was classified as obvious enhancement (>90 HU), medium enhancement (60-90 HU) and mild enhancement (<60 HU). CT features of various kinds of small bowel diseases were analyzed. Results: The hypertonic mannitol saline was acceptable by patients, except 5 patients with diarrhea. The filling degree of stomach, intestine and and colon was classified as satisfactory in 46 cases, better in 23 cases and unsatisfactory in 12 cases. The maximum outer diameters of small bowel in different segments were 24 mm ± 4.5 mm at duodenum, 24 mm ±3.9 mm at jejunum and 23 mm ±3.3 mm at ileum respectively. The length and superposition of small intestine were classified as dense-type in 7 cases, uniformity-type in 58

  3. Colon cancer mimicking physiologic FDG uptake: with using of negative oral contrast

    International Nuclear Information System (INIS)

    Jeong, Young Jin; Kang, Do Young

    2006-01-01

    A 64-year-old female with glioblastoma multiforme (GBM) was assigned to our department for whole body PET/CT scan. She ingested 1 liter of pure water as negative oral contrast just before PET/CT examination. FDG-PET/CT images showed a very intense hypermetabolic, focal lesion in the abdominal cavity around descending colon. The SUVmax of the lesion was 17.2. But there was no abnormal lesion corresponded to the area of PET scan in the combined contrast enhanced CT scan. We suggested considering a malignant lesion due to very intense glycolytic activity. Conventional abdominal CT scan and colonoscopy were accomplished within one week after PET/CT evaluation. There was no abnormality in both examinations. We executed follow-up PET/CT evaluation after 1 month and couldn't find any abnormality around the corresponding area. So we concluded the hypermetabolism was colonic physiologic uptake. A colonic physiologic uptake is a well known cause of false positive finding. Nuclear physicians should be considered the possibility of malignancy when interpret focal colonic uptake, especially incidental finding. 1-3) There are a few reports that using of negative oral contrast is able to reduce gastrointestinal physiologic uptakes. 4,5) But as we can see in this case, although we used negative oral contrast, intense physiologic uptake is detected and maxSUV is able to up to 17.2. So, it is important to keep a fact in mind. Even though there is a colonic physiologic uptake in PET/CT image, it may be able to show very intense hypermetabolism regardless of using negative oral contrast

  4. Pineapple juice labeled with gadolinium: a convenient oral contrast for magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Coppens, Emmanuel; Metens, Thierry; Winant, Catherine; Matos, Celso

    2005-01-01

    The aim of our study was to prepare in vitro a pineapple juice (PJ) solution labeled with a minimal gadolinium concentration working as a negative contrast agent in heavily T2-weighted imaging and to assess that solution in vivo as a negative oral contrast agent for magnetic resonance cholangiopancreatography (MRCP). Three PJs were compared in vitro according to their T2. Increasing concentrations of gadolinium (Gd)-DOTA in PJ were assessed in vitro for T2 reduction. Single-shot turbo spin echo T2-weighted MR cholangiopancreatograms were obtained for 35 patients with suspected biliopancreatic duct disease, before and after ingestion of the PJ/Gd-DOTA solution. Signal intensity (SI) measurements of gastroduodenal lumens, pancreatobiliary ducts, and image quality scores were obtained systematically before and after contrast ingestion. The in vitro selected Gd-DOTA concentration in the PJ was 2.76 mmol/l. Ingestion of 180 ml of PJ labeled with 1 ml of Gd-DOTA eliminated efficiently the gastroduodenal SI in MRCP, improving significantly the rates of complete visualization of the pancreatobiliary ducts (P<0.01) and the MRCP image quality scores (P<0.05). All patients easily ingested the contrast solution and found the solution palatable. PJ labeled with gadolinium constituted an efficient and convenient negative oral contrast agent for MRCP. (orig.)

  5. Pineapple juice labeled with gadolinium: a convenient oral contrast for magnetic resonance cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Coppens, Emmanuel; Metens, Thierry; Winant, Catherine; Matos, Celso [Hopital Erasme, Universite Libre de Bruxelles, Department of Radiology, Division of Magnetic Resonance, Brussels (Belgium)

    2005-10-01

    The aim of our study was to prepare in vitro a pineapple juice (PJ) solution labeled with a minimal gadolinium concentration working as a negative contrast agent in heavily T2-weighted imaging and to assess that solution in vivo as a negative oral contrast agent for magnetic resonance cholangiopancreatography (MRCP). Three PJs were compared in vitro according to their T2. Increasing concentrations of gadolinium (Gd)-DOTA in PJ were assessed in vitro for T2 reduction. Single-shot turbo spin echo T2-weighted MR cholangiopancreatograms were obtained for 35 patients with suspected biliopancreatic duct disease, before and after ingestion of the PJ/Gd-DOTA solution. Signal intensity (SI) measurements of gastroduodenal lumens, pancreatobiliary ducts, and image quality scores were obtained systematically before and after contrast ingestion. The in vitro selected Gd-DOTA concentration in the PJ was 2.76 mmol/l. Ingestion of 180 ml of PJ labeled with 1 ml of Gd-DOTA eliminated efficiently the gastroduodenal SI in MRCP, improving significantly the rates of complete visualization of the pancreatobiliary ducts (P<0.01) and the MRCP image quality scores (P<0.05). All patients easily ingested the contrast solution and found the solution palatable. PJ labeled with gadolinium constituted an efficient and convenient negative oral contrast agent for MRCP. (orig.)

  6. Physical and chemical stability of proflavine contrast agent solutions for early detection of oral cancer.

    Science.gov (United States)

    Kawedia, Jitesh D; Zhang, Yan-Ping; Myers, Alan L; Richards-Kortum, Rebecca R; Kramer, Mark A; Gillenwater, Ann M; Culotta, Kirk S

    2016-02-01

    Proflavine hemisulfate solution is a fluorescence contrast agent to visualize cell nuclei using high-resolution optical imaging devices such as the high-resolution microendoscope. These devices provide real-time imaging to distinguish between normal versus neoplastic tissue. These images could be helpful for early screening of oral cancer and its precursors and to determine accurate margins of malignant tissue for ablative surgery. Extemporaneous preparation of proflavine solution for these diagnostic procedures requires preparation in batches and long-term storage to improve compounding efficiency in the pharmacy. However, there is a paucity of long-term stability data for proflavine contrast solutions. The physical and chemical stability of 0.01% (10 mg/100 ml) proflavine hemisulfate solutions prepared in sterile water was determined following storage at refrigeration (4-8℃) and room temperature (23℃). Concentrations of proflavine were measured at predetermined time points up to 12 months using a validated stability-indicating high-performance liquid chromatography method. Proflavine solutions stored under refrigeration were physically and chemically stable for at least 12 months with concentrations ranging from 95% to 105% compared to initial concentration. However, in solutions stored at room temperature increased turbidity and particulates were observed in some of the tested vials at 9 months and 12 months with peak particle count reaching 17-fold increase compared to baseline. Solutions stored at room temperature were chemically stable up to six months (94-105%). Proflavine solutions at concentration of 0.01% were chemically and physically stable for at least 12 months under refrigeration. The solution was chemically stable for six months when stored at room temperature. We recommend long-term storage of proflavine solutions under refrigeration prior to diagnostic procedure. © The Author(s) 2014.

  7. Depiction of normal gastrointestinal anatomy with MDCT: Comparison of low- and high-attenuation oral contrast media

    International Nuclear Information System (INIS)

    Erturk, Sukru Mehmet; Mortele, Koenraad J.; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G.; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R.

    2008-01-01

    Purpose: To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). Materials and methods: A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Results: Duodenal, jejunal and ileal distention (p < 0.05, <0.001, <0.001, respectively) and wall visualization (p < 0.05, <0.01, <0.05, respectively) scores with low-attenuation contrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (p < 0.05, <0.01, respectively) were significantly higher than those with high-attenuation contrast medium, for reader 2. Interobserver agreement was fair to good for both distention (κ-range: 0.41-0.74) and wall visualization (κ-range: 0.48-0.71). Conclusion: MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium

  8. Method and apparatus to characterize ultrasonically reflective contrast agents

    Science.gov (United States)

    Pretlow, Robert A., III (Inventor)

    1993-01-01

    A method and apparatus for characterizing the time and frequency response of an ultrasonically reflective contrast agent is disclosed. An ultrasonically reflective contrast agent is injected, under constant pressure, into a fluid flowing through a pump flow circuit. The fluid and the ultrasonically reflective contrast agent are uniformly mixed in a mixing chamber, and the uniform mixture is passed through a contrast agent chamber. The contrast agent chamber is acoustically and axially interposed between an ultrasonic transducer chamber and an acoustic isolation chamber. A pulse of ultrasonic energy is transmitted into the contrast agent chamber from the ultrasonic transducer chamber. An echo waveform is received from the ultrasonically reflective contrast agent, and it is analyzed to determine the time and frequency response of the ultrasonically reflective contrast agent.

  9. Comparison between computed tomography with oral oil-based contrast and laparotomy for gastric cancer staging

    International Nuclear Information System (INIS)

    Marco, S. F.; Garcia-Vila, J. H.; Cervera, J.; Gomez, R.; Piqueras, R. M.; Perona, I.; Escrig, J.; Salvador, J. L.

    2000-01-01

    To compare the utility of conventional computed tomography (CT) with oral oil-based contrast with that of laparotomy in the preoperative staging of gastric cancer. We prospectively studied 41 patients diagnosed as having gastric adenocarcinoma according to the results of endoscopy and biopsy. Applying the TNM classification for gastric cancer staging, we compared the findings in CT associated with oral oil-based contrast and intraoperative staging with definitive postoperative pathological staging. Definitive pathological studies demonstrated that there were 7 stage T1-T2 lesions, 26 stage T3 and 8 stage T4. The assessment of lymph node involvement showed that 10 patients presented stage N0 and 31 stage N1-N3. Ten patients had metastases. The diagnostic reliability for tumor staging according to CT was 56% versus 80% for laparotomy. In the determination of nodal involvement CT had a diagnostic yield of 71% versus 6% for laparotomy. Metastatic disease was correctly diagnosed by CT in 83% of cases versus 88% by laparotomy. There were no statistically significant differences between CT with oral oil-based contrast and laparotomy for the staging of nodal involvement and metastases. However, the CT diagnosis was significantly more reliable than laparotomy for the determination of tumor infiltration. (Author) 21 refs

  10. Searching for an alternative oral contrast agent for GI tract MR imaging; in vitro phase, initial report

    International Nuclear Information System (INIS)

    Okla, W.; Szeszkowski, W.; Cieszanowski, A.; Golebiowski, M.

    2002-01-01

    MR has been recently considered to be suitable method for detection GI tract pathologies. A few substances (some of a natural origin) seem to act as an efficient oral MR contrast agents. The aim of this study is to find an alternative substance, which can be administrated orally to patients in order to enhance signal intensity (SI). The ideal agent should have a biphase pattern (high SI in T1 and low in T2), and should be nontoxic and cost effective. Phantom experiments were conducted with 1.5 T MR scanner. T1W and T2W sequences were used for initial estimation. Number of different agents such as: water, Gd-DTPA, barium sulfate, green tea, blueberry juice, cranberry juice, blackcurrant juice, and some more were evaluated. Signal intensity was measured by using elliptical region of interest (ROI). MR imaging in one patient with stomach cancer was also performed. In T1W-FFE sequence cranberry juice reached satisfactorily high signal (SI=1760.14). In T2W-TSE sequence this substance reduced signal intensity (SI=23.10) almost to background level. Blueberry juice appear to be the next substance capable to generate high signal (SI=1558.31) in T1W sequence (T1-TSE). MR examination of a patient with stomach adenocarcinoma (using blueberry juice as an oral contrast agent) satisfactorily depicted and delineated tumor mass on both: T1W and T2W images. Cranberry juice and blueberry juice seemed to act effectively as oral contrast agents for gastrointestinal MR imaging. Thus they need further exploration and trials. (author)

  11. Evaluation of date syrup as an oral negative contrast agent for MRCP.

    Science.gov (United States)

    Govindarajan, Arunkumar; Lakshmanan, Prakash Manikka; Sarawagi, Radha; Prabhakaran, Velu

    2014-11-01

    The purpose of this study was to compare the in vitro effects of date syrup with those of other contrast agents by qualitative and quantitative analysis and in vivo evaluation of the use of date syrup to improve the quality of MRCP images. Phantoms containing date syrup, ferumoxsil, pineapple juice, and water were imaged by 1.5-T MRI with T2-weighted and MRCP sequences, and signal-to-noise ratios were calculated. Biochemical analysis of date syrup was performed to find the nature of iron in it, and the iron content was quantified by energy-dispersive x-ray spectroscopy. Sixty patients underwent MRCP before and 30 minutes after ingestion of 100 mL of date syrup. Unenhanced and contrast-enhanced images were scored for gastrointestinal tract signal suppression and visualization of various pancreaticobiliary structures. In vitro evaluation showed that images obtained with date syrup had a signal-to-noise ratio comparable to that of images obtained with ferumoxsil in T2-weighted and MRCP sequences. The iron concentration in date syrup was 2.6 mg/dL, and it was in ferric form. Images obtained after oral contrast administration had statistically significant improvement in gastrointestinal tract signal suppression (p Date syrup can be used as a negative oral contrast agent for gastrointestinal tract signal suppression during MRCP and for improving visualization of various pancreaticobiliary structures.

  12. Evaluation of potential practical oral contrast agents for pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bisset, G.S. III; Cincinnati Univ., OH; Children's Hospital Medical Center, Cincinnati, OH

    1989-01-01

    Development of a practical oral contrast agent for magnetic resonance imaging is necessary to improve differentiation of bowel from adjacent structures. In order to find a readily available, inexpensive, non-toxic, palatable solution for use in the pediatric population, several formulas, milk products and a common oral sedative were evaluated in vitro. T1, T2 and signal intensity measurements were performed on a 1.5 T system. Similac with standard iron proved to be a useful high signal intensity agent on multiple pulse sequences. Early in vivo experience in four normal volunteers indicates that this agent provides excellent delineation of the stomach and duodenum from contiguous viscera. Distal small bowel visualization is less predictabel. Further clinical trials should confirm the utility of this solution, which contains a combination of iron salts and paramagnetic metallic ions. (orig.)

  13. Gadolinium DTPA as oral contrast medium for MRT of the pancreas

    International Nuclear Information System (INIS)

    Neumann, K.; Kaminsky, S.; Gogoll, M.; Langer, M.; Felix, R.

    1991-01-01

    52 patients with normal pancreas, pancreatitis and pancreatic tumors were examined by magnetic resonance imaging (Magnetom 0,5 T). Using T 1 -, proton density- and T 2 -weighted spin-echo sequences images were obtained before and after oral administration of Gadolinium-DTPA (Gd-DTPA, 1 mM, 15 g/l Mannit, 5-13 ml/kg). Gd-DTPA resulted in hyperintense labeling of small bowel in all sequences and improved visualization of pancreatic head, body and tail in 15, 14 and 7 of 27 patients with normal pancreas and in 17, 8 and 6 of 25 patients with diseased pancreas. Better delineation of pseudocysts and tumorous gut wall invasion were diagnostically profitable. With regard to motion artifact reduced MRI of the intestine using fast sequences Gd-DTPA may be a suitable oral contrast agent to improve the imaging of the pancreas. (orig.) [de

  14. Magnesium sulfate as an oral contrast medium in magnetic resonance imaging of the small intestine.

    Science.gov (United States)

    Shi, Hao; Liu, Cun; Ding, Hong Yu; Li, Chun Wei

    2012-03-01

    To explore the use of magnesium sulfate (MgSO4) as an oral contrast medium (CM) in MRI of the small intestine. By comparing MgSO4 SNRs at different concentrations, we determined that 2.5% MgSO4 is the ideal concentration for small bowel MRI. Twenty volunteers underwent MRI after drinking 2.5% MgSO4. Thirty-one patients with clinical suspicion of small intestinal pathology underwent both MRI and the air-barium contrast examination. The patient's tolerance, side effects and complications were noted. 2.5% MgSO4 can decrease the absorption of water and fully fill the enteric cavity, thereby increasing the contrast between the intestinal wall and lumen and facilitating radiographic examination of the small bowel. The mean diameter of the small intestine was 19.8±1.21 mm in the 20 volunteers consuming 2.5% MgSO4 and 12.7±0.84 mm in the 20 volunteers given water. There was a significant difference (P0.05) in side effects between MgSO4 and water groups. Small intestinal MRI was successfully performed in all 31 patients, who were also examined by the double contrast barium, which gave almost identical diagnoses to MRI in all cases except for 1 patient with small intestinal hemorrhage. MRI with 2.5% MgSO4 can demonstrate intestinal abnormalities. Therefore, 2.5% MgSO4 solution is an ideal oral CM for small bowel MRI. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  15. Interindividual testing of water-soluble oral contrast media in respect of diagnostic ranking, side effects and taste

    International Nuclear Information System (INIS)

    Staebler, A.; Fink, U.; Siuda, S.; Neville, S.

    1989-01-01

    Three groups of patients (n = 55, 52 and 54) were examined with the X-ray contrast media Gastrografin, Peritrast-Oral GI, and Telebrix Gastro to assess the diagnostic ranking, side effects and taste of watersoluble oral contrast media. No significant differences were seen in respect of diagnostic ranking and side effects. Side effects were exclusively abdominal symptoms; there was no difference with regard to laxative action. Telebrix Gastroas accepted significantly better in respect of taste than Gastrografin and Peritrast-Oral GI. (orig.) [de

  16. Gastric stromal tumor: two-phase dynamic CT findings with water as oral contrast agents

    International Nuclear Information System (INIS)

    Lee, Se Hyo; Cho, June Sik; Shin, Kyung Sook; Jeong, Ki Ho; Park, Jin Yong; Yu, Ho Jun; Kim, Young Min; Jeon, Kwang Jin

    2000-01-01

    To evaluate two-phase dynamic CT with water as oral contrast agents in the CT diagnosis of gastric stromal tumors. We retrospectively reviewed the CT findings in 21 patients with pathologically proven gastric stromal tumors. Six were found to be benign, twelve were malignant, and there were three cases of STUMP (stromal tumor uncertain malignant potential). Two-phase dynamic CT scans with water as oral contrast agents were obtained 60-70 secs (portal phase) and 3 mins (equilibrium phase) after the start of IV contrast administration. We determined the size, growth pattern, and enhancement pattern of the tumors and overlying mucosa, the presence or absence of ulceration and necrosis, tumor extent, and lymph nod and distant metastasis. The CT and pathologic findings were correlated. All six benign tumors and three STUMP were less than 5.5 cm in size, and during the portal phase showed round endogastric masses with highly enhanced, intact overlying mucosa. Twelve malignant tumors were 4.5-15.5 cm in size (mean, 11.5 cm); an endogastric mass was seen in three cases, an exogastric mass in one, and a mixed pattern in eight. On portal phase images the tumors were not significantly enhanced, but highly enhanced feeding vessels were noted in five larger tumors (greater than 10 cm). All 12 malignant tumors showed ulceration and necrosis, and interruption of overlying mucosa was clearly seen during the portal phase. We were readily able to evaluate tumor extent during this phase, and in ten malignant tumors there was no invasion of adjacent organs. Seven malignant tumors showed air density within their necrotic portion (p less than 0.05). On equilibrium phase images, all malignant tumors showed heterogeneous enhancement due to necrosis, and poorly enhanced overlying mucosa. Dynamic CT during the portal phase with water as oral contrast agents was useful for depicting the submucosal origin of gastric stromal tumors and for evaluating the extent of malignant stromal tumors. Our

  17. A developed unsharp masking method for images contrast enhancement

    International Nuclear Information System (INIS)

    Zaafouri, A.; Sayadi, M.; Fnaiech, F.

    2011-01-01

    In this paper, we propose a developed unsharp masking process for contrast image enhancement. The main idea here is to enhance the dark and bright area in the same way which matches the response of human visual system well. Then in order to reduce the noise effect, a mean weighted high pass filter is used for edge extraction. The proposed method gives satisfactory results for wide range of low contrast images compared with others known approaches.

  18. Dynamic texture perception, oral processing behaviour and bolus properties of emulsion-filled gels with and without contrasting mechanical properties

    NARCIS (Netherlands)

    Devezeaux de Lavergne, M.S.M.; Tournier, C.; Bertrand, D.; Salles, C.; Velde, van de F.; Stieger, M.A.

    2016-01-01

    Many highly palatable foods are composed of multiple components which can have considerably different mechanical properties leading to contrasting texture sensations. The aim of this study was to better understand the impact of contrasting mechanical properties in semi-solid gels on oral processing

  19. Advanced method of double contrast examination of the stomach

    International Nuclear Information System (INIS)

    Vlasov, P.V.; Yakimenko, V.F.

    1981-01-01

    An advanced method of double contrast examination of the stomach with the use of high concentrated barium suspension is described. It is shown that concentration of barium suspension must be not less than 200 mass/volume per cent to obtain the sharp image of the mucosal microrelief 6 standard position are recommended for the double contrast examination of all stomach walls. 200 patients with different digestive system diseases are examined with the help of developed methods. The sharp image of the mucosal microrelief is obtained in 70% cases [ru

  20. Ct enterography/ct abdomen and pelvis using neutral oral contrast. a new combination of natural products

    International Nuclear Information System (INIS)

    Aslam, M.O.

    2014-01-01

    Our purpose was to assess the performance of a new combination of neutral oral contrast for CT abdomen and CT Enterography in comparison with commercially available neutral oral contrast VoLumen. Seventy three consecutive patients were given sorbitol/CMC (Carboxy Methyl Cellulose) solution or VoLumen as oral contrast agent for abdominal computed tomography (CT) scan. 23 patients were male and 37 females. Age range was between 16 and 67 years. Since the use of CT scan for abdominal pathologies, there was need to separate bowel loops to localize the pathology. Three types of oral contrast can be used in CT-Scan abdomen; Positive, Neutral and negative. The above used contrasts are Neutral contrast these refers to agents that have an attenuation value similar to that of water (0-30 H).Our results show this new combination of Cc and Sorbitol to be equally good as VoLumen, for luminal distension and mural details, in duodenum and jejunum. While better than VoLumen for Ileal distension. (author)

  1. Contrasting Nephropathic Responses to Oral Administration of Extract of Cultured Penicillium polonicum in Rat and Primate

    Directory of Open Access Journals (Sweden)

    John E. Fincham

    2010-08-01

    Full Text Available Liquid- or solid substrate-cultured Penicillium polonicum administered in feed to rats over several days evokes a histopathological response in kidney involving apoptosis and abnormal mitosis in proximal tubules. The amphoteric toxin is yet only partly characterized, but can be isolated from cultured sporulating biomass in a fraction that is soluble in water and ethanol, and exchangeable on either anion- or cation-exchange resins. After several weeks of treatment renal proximal tubule distortion became striking on account of karyocytomegaly, but even treatment for nearly two years remained asymptomatic. Extract from a batch of solid substrate fermentation of P. polonicum on shredded wheat was incorporated into feed for rats during four consecutive days, and also given as an aqueous solution by oral gavage to a vervet monkey daily for 10 days. Treatment was asymptomatic for both types of animal. Rat response was evident as the typical renal apoptosis and karyomegaly. In contrast there was no such response in the primate; and neither creatinine clearance nor any haematological characteristic or serum component concentration deviated from a control or from historical data for this primate. The contrast is discussed concerning other negative findings for P. polonicum in pigs and hamsters. Renal karyomegaly, as a common rat response to persistent exposure to ochratoxin A, is not known in humans suspected as being exposed to more than the usual trace amounts of dietary ochratoxin A. Therefore the present findings question assumptions that human response to ochratoxin A conforms to that in the rat.

  2. Evaluation of a low-dose CT protocol with oral contrast for assessment of acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Platon, Alexandra; Jlassi, Helmi; Becker, Christoph D.; Poletti, Pierre-Alexandre [University Hospital of Geneva, Department of Radiology, Geneva 14 (Switzerland); Rutschmann, Olivier T. [University Hospital of Geneva, Emergency Center, Geneva (Switzerland); Verdun, Francis R. [University Institute for Radiation Physics, Lausanne (Switzerland); Gervaz, Pascal [University Hospital of Geneva, Clinic of Digestive Surgery, Geneva (Switzerland)

    2009-02-15

    The aim of this study was to evaluate a low-dose CT with oral contrast medium (LDCT) for the diagnosis of acute appendicitis and compare its performance with standard-dose i.v. contrast-enhanced CT (standard CT) according to patients' BMIs. Eighty-six consecutive patients admitted with suspicion of acute appendicitis underwent LDCT (30 mAs), followed by standard CT (180 mAs). Both examinations were reviewed by two experienced radiologists for direct and indirect signs of appendicitis. Clinical and surgical follow-up was considered as the reference standard. Appendicitis was confirmed by surgery in 37 (43%) of the 86 patients. Twenty-nine (34%) patients eventually had an alternative discharge diagnosis to explain their abdominal pain. Clinical and biological follow-up was uneventful in 20 (23%) patients. LDCT and standard CT had the same sensitivity (100%, 33/33) and specificity (98%, 45/46) to diagnose appendicitis in patients with a body mass index (BMI) {>=} 18.5. In slim patients (BMI < 18.5), sensitivity to diagnose appendicitis was 50% (2/4) for LDCT and 100% (4/4) for standard CT, while specificity was identical for both techniques (67%, 2/3). LDCT may play a role in the diagnostic workup of patients with a BMI {>=} 18.5. (orig.)

  3. Evaluation of a low-dose CT protocol with oral contrast for assessment of acute appendicitis

    International Nuclear Information System (INIS)

    Platon, Alexandra; Jlassi, Helmi; Becker, Christoph D.; Poletti, Pierre-Alexandre; Rutschmann, Olivier T.; Verdun, Francis R.; Gervaz, Pascal

    2009-01-01

    The aim of this study was to evaluate a low-dose CT with oral contrast medium (LDCT) for the diagnosis of acute appendicitis and compare its performance with standard-dose i.v. contrast-enhanced CT (standard CT) according to patients' BMIs. Eighty-six consecutive patients admitted with suspicion of acute appendicitis underwent LDCT (30 mAs), followed by standard CT (180 mAs). Both examinations were reviewed by two experienced radiologists for direct and indirect signs of appendicitis. Clinical and surgical follow-up was considered as the reference standard. Appendicitis was confirmed by surgery in 37 (43%) of the 86 patients. Twenty-nine (34%) patients eventually had an alternative discharge diagnosis to explain their abdominal pain. Clinical and biological follow-up was uneventful in 20 (23%) patients. LDCT and standard CT had the same sensitivity (100%, 33/33) and specificity (98%, 45/46) to diagnose appendicitis in patients with a body mass index (BMI) ≥ 18.5. In slim patients (BMI < 18.5), sensitivity to diagnose appendicitis was 50% (2/4) for LDCT and 100% (4/4) for standard CT, while specificity was identical for both techniques (67%, 2/3). LDCT may play a role in the diagnostic workup of patients with a BMI ≥ 18.5. (orig.)

  4. Local recurrence of rectal cancer: MR imaging before and after oral superparamagnetic particles vs contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Blomqvist, L.; Ohlsen, H.; Holm, T.

    2000-01-01

    The aim of this study was to compare three imaging strategies for the diagnosis of local recurrence of rectal cancer: (a) MR imaging; (b) MR imaging after administration of enteral superparamagnetic particles (Ferristene); and (c) contrast-enhanced CT. Seventeen patients with previous surgery for rectal cancer were examined, 12 patients with local tumour recurrence in the pelvis and 5 patients with postoperative changes. Pelvic multi-coil MR imaging before and after oral administration of superparamagnetic contrast medium [Abdoscan (Ferristene USAN), Nycomed-Amersham, Lidingoe, Sweden] as well as abdominal and pelvic CT was performed in all patients. The examinations were independently evaluated by three different radiologists. The general effect of the oral MR contrast medium, the delineation of normal and pathological structures as well as confidence in the diagnosis were registered on a visual analog scale (VAS). The diagnosis according to MR before and after oral contrast medium, and CT, was compared, in 16 patients, with the final diagnosis which was verified by biopsy (n = 3), surgery (n = 6), clinical follow-up (n = 4) and by follow-up with MR or CT (n = 3). No significant improvement in MR image quality was found after enteral contrast medium. The post-contrast MR diagnosis was not changed in any of the patients. The diagnosis on MR correlated with the final diagnosis in 12 of 16 patients (sensitivity 91 %, accuracy 62 %) and the diagnosis on CT in 11 of 16 patients (sensitivity 82 %, accuracy 56 %). The radiologists' ''confidence'' in the diagnosis and the degree of accordance with the final diagnosis did not score higher on MR after than before oral contrast administration; however, the accordance with the final diagnosis scored better on MR than on CT. No advantages of orally administered superparamagnetic contrast medium were observed in the examined patient group. Magnetic resonance is preferable to CT in diagnosing local tumour recurrence. (orig.)

  5. METHOD OF RARE TERM CONTRASTIVE EXTRACTION FROM NATURAL LANGUAGE TEXTS

    Directory of Open Access Journals (Sweden)

    I. A. Bessmertny

    2017-01-01

    Full Text Available The paper considers a problem of automatic domain term extraction from documents corpus by means of a contrast collection. Existing contrastive methods successfully extract often used terms but mishandle rare terms. This could yield poorness of the resulting thesaurus. Assessment of point-wise mutual information is one of the known statistical methods of term extraction and it finds rare terms successfully. Although, it extracts many false terms at that. The proposed approach consists of point-wise mutual information application for rare terms extraction and filtering of candidates by criterion of joint occurrence with the other candidates. We build “documents-by-terms” matrix that is subjected to singular value decomposition to eliminate noise and reveal strong interconnections. Then we pass on to the resulting matrix “terms-by-terms” that reproduces strength of interconnections between words. This approach was approved on a documents collection from “Geology” domain with the use of contrast documents from such topics as “Politics”, “Culture”, “Economics” and “Accidents” on some Internet resources. The experimental results demonstrate operability of this method for rare terms extraction.

  6. An evaluation of the use of oral contrast media in abdominopelvic CT

    Energy Technology Data Exchange (ETDEWEB)

    Buttigieg, Erica Lauren; Cortis, Kelvin; Galea Soler, Sandro [Mater Dei Hospital, Medical Imaging Department, Msida (Malta); Borg Grima, Karen; Zarb, Francis [Mater Dei Hospital, Faculty of Health Sciences, Msida (Malta)

    2014-11-15

    To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. (orig.)

  7. An evaluation of the use of oral contrast media in abdominopelvic CT

    International Nuclear Information System (INIS)

    Buttigieg, Erica Lauren; Cortis, Kelvin; Galea Soler, Sandro; Borg Grima, Karen; Zarb, Francis

    2014-01-01

    To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. (orig.)

  8. A finite-difference contrast source inversion method

    International Nuclear Information System (INIS)

    Abubakar, A; Hu, W; Habashy, T M; Van den Berg, P M

    2008-01-01

    We present a contrast source inversion (CSI) algorithm using a finite-difference (FD) approach as its backbone for reconstructing the unknown material properties of inhomogeneous objects embedded in a known inhomogeneous background medium. Unlike the CSI method using the integral equation (IE) approach, the FD-CSI method can readily employ an arbitrary inhomogeneous medium as its background. The ability to use an inhomogeneous background medium has made this algorithm very suitable to be used in through-wall imaging and time-lapse inversion applications. Similar to the IE-CSI algorithm the unknown contrast sources and contrast function are updated alternately to reconstruct the unknown objects without requiring the solution of the full forward problem at each iteration step in the optimization process. The FD solver is formulated in the frequency domain and it is equipped with a perfectly matched layer (PML) absorbing boundary condition. The FD operator used in the FD-CSI method is only dependent on the background medium and the frequency of operation, thus it does not change throughout the inversion process. Therefore, at least for the two-dimensional (2D) configurations, where the size of the stiffness matrix is manageable, the FD stiffness matrix can be inverted using a non-iterative inversion matrix approach such as a Gauss elimination method for the sparse matrix. In this case, an LU decomposition needs to be done only once and can then be reused for multiple source positions and in successive iterations of the inversion. Numerical experiments show that this FD-CSI algorithm has an excellent performance for inverting inhomogeneous objects embedded in an inhomogeneous background medium

  9. MR-imaging of the breast at 0.5 Tesla: menstrual-cycle dependency of parenchymal contrast enhancement in healthy volunteers with oral contraceptive use?

    International Nuclear Information System (INIS)

    Lorenzen, J.; Welger, J.; Krupski, G.; Adam, G.; Lisboa, B.W.

    2003-01-01

    Introduction: To evaluate changes of contrast medium enhancement of the breast parenchyma due to menstrual cycle in healthy volunteers with oral contraceptive use in MR-imaging of the breast. Material and Methods: 15 healthy volunteers (age: 22 - 36, mean 28,2) without breast disease were examined two times during one menstrual cycle (days 7 - 14 and days 21 - 2). Two volunteers were examined only in the second part of the cycle (days 21 - 2). All volunteers used oral contraceptives for more than 6 month continuously. Examinations were performed with a 0,5 T magnet (dynamic 3D-gradient echo protocol with subtraction postprocessing). We evaluated the number of enhancing foci and the parenchymal contrast medium enhancement during the different phases of the cycle by region of interest. Results: Only a total of two enhancing foci were found in 2 of 17 volunteers. Time/signal intensity diagrams in these both cases were not suspicious ( [de

  10. MRI of the small bowel: can sufficient bowel distension be achieved with small volumes of oral contrast?

    International Nuclear Information System (INIS)

    Kinner, Sonja; Kuehle, Christiane A.; Ladd, Susanne C.; Barkhausen, Joerg; Herbig, Sebastian; Haag, Sebastian; Lauenstein, Thomas C.

    2008-01-01

    Sufficient luminal distension is mandatory for small bowel imaging. However, patients often are unable to ingest volumes of currently applied oral contrast compounds. The aim of this study was to evaluate if administration of low doses of an oral contrast agent with high-osmolarity leads to sufficient and diagnostic bowel distension. Six healthy volunteers ingested at different occasions 150, 300 and 450 ml of a commercially available oral contrast agent (Banana Smoothie Readi-Cat, E-Z-EM; 194 mOsmol/l). Two-dimensional TrueFISP data sets were acquired in 5-min intervals up to 45 min after contrast ingestion. Small bowel distension was quantified using a visual five-grade ranking (5 very good distension, 1 = collapsed bowel). Results were statistically compared using a Wilcoxon-Rank test. Ingestion of 450 ml and 300 ml resulted in a significantly better distension than 150 ml. The all-over average distension value for 450 ml amounted to 3.4 (300 ml: 3.0, 150 ml: 2.3) and diagnostic bowel distension could be found throughout the small intestine. Even 45 min after ingestion of 450 ml the jejunum and ileum could be reliably analyzed. Small bowel imaging with low doses of contrast leads to diagnostic distension values in healthy subjects when a high-osmolarity substance is applied. These findings may help to further refine small bowel MRI techniques, but need to be confirmed in patients with small bowel disorders. (orig.)

  11. Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm

    International Nuclear Information System (INIS)

    Ahmadian, Alireza; Ay, Mohammad R.; Sarkar, Saeed; Bidgoli, Javad H.; Zaidi, Habib

    2008-01-01

    Oral contrast is usually administered in most X-ray computed tomography (CT) examinations of the abdomen and the pelvis as it allows more accurate identification of the bowel and facilitates the interpretation of abdominal and pelvic CT studies. However, the misclassification of contrast medium with high-density bone in CT-based attenuation correction (CTAC) is known to generate artifacts in the attenuation map (μmap), thus resulting in overcorrection for attenuation of positron emission tomography (PET) images. In this study, we developed an automated algorithm for segmentation and classification of regions containing oral contrast medium to correct for artifacts in CT-attenuation-corrected PET images using the segmented contrast correction (SCC) algorithm. The proposed algorithm consists of two steps: first, high CT number object segmentation using combined region- and boundary-based segmentation and second, object classification to bone and contrast agent using a knowledge-based nonlinear fuzzy classifier. Thereafter, the CT numbers of pixels belonging to the region classified as contrast medium are substituted with their equivalent effective bone CT numbers using the SCC algorithm. The generated CT images are then down-sampled followed by Gaussian smoothing to match the resolution of PET images. A piecewise calibration curve was then used to convert CT pixel values to linear attenuation coefficients at 511 keV. The visual assessment of segmented regions performed by an experienced radiologist confirmed the accuracy of the segmentation and classification algorithms for delineation of contrast-enhanced regions in clinical CT images. The quantitative analysis of generated μmaps of 21 clinical CT colonoscopy datasets showed an overestimation ranging between 24.4% and 37.3% in the 3D-classified regions depending on their volume and the concentration of contrast medium. Two PET/CT studies known to be problematic demonstrated the applicability of the technique in

  12. Patients' oral hydration levels and incidence of immediate to short-term mild side-effects in contrast agent enhanced MRI diagnostics

    International Nuclear Information System (INIS)

    Jonker, Leon; Fallahi, Farshid

    2015-01-01

    Aim: Gadolinium-based contrast agents for radiodiagnostic purposes can lead to side effects, including nephrotoxicity in patients with renal insufficiency. This study evaluated whether the occurrence of mild side effects from gadolinium-based contrast enhanced magnetic resonance imaging (MRI) correlates to patients' oral hydration levels. Methods: Oral fluid intake levels 24 h pre- and 24 h post-MRI, as well as incidence of mild side-effects experienced 30 min and 24 h post-MRI were recorded by using a patient self-reporting questionnaire. Results: A total of 174 patients, 29 controls, 98 administered Prohance and 47 receiving Dotarem, were enrolled. Overall, the most frequently reported side-effect was headache; nausea only occurred in patients receiving contrast agent. One or more side-effects experienced 24 h following the MRI scan were reported by 10% (controls), 24% (Prohance) and 22% (Dotarem) of patients, respectively. Multivariate ordinal regression analysis showed that only male gender (OR 0.24, 95% CI 0.11–0.53) was statistically significantly associated with a decreased incidence of side-effects 30 min after MRI. At 24-h post MRI, a lack of contrast agent (OR 0.40, 95% CI 0.09–1.74) and male gender (OR 0.46, 95% CI 0.19–1.09) were associated with fewer side-effects. Conclusions: The level oral fluid intake before and after undergoing gadolinium-based contrast-enhanced MRI does not appear to markedly affect the incidence of common undesirable mild symptoms experienced shortly after the procedure. Confounding differences between patients in reporting side-effects may contribute to these findings. - Highlights: • We assess the incidence of patient-reported side-effects after contrast-enhanced MRI. • We examine the potential impact of oral hydration levels on side-effects. • Patient reported side-effects are high compared to those reported by clinicians. • Female gender and contrast agent itself are associated with increased side

  13. Comparison of 3% sorbitol vs psyllium fibre as oral contrast agents in MR enterography.

    Science.gov (United States)

    Saini, Sidharth; Colak, Errol; Anthwal, Shalini; Vlachou, Paraskevi A; Raikhlin, Antony; Kirpalani, Anish

    2014-10-01

    To compare the degree of small bowel distension achieved by 3% sorbitol, a high osmolarity solution, and a psyllium-based bulk fibre as oral contrast agents (OCAs) in MR enterography (MRE). This retrospective study was approved by our institutional review board. A total of 45 consecutive normal MRE examinations (sorbitol, n = 20; psyllium, n = 25) were reviewed. The patients received either 1.5 l of 3% sorbitol or 2 l of 1.6 g kg(-1) psyllium prior to imaging. Quantitative small bowel distension measurements were taken in five segments: proximal jejunum, distal jejunum, proximal ileum, distal ileum and terminal ileum by two independent radiologists. Distension in these five segments was also qualitatively graded from 0 (very poor) to 4 (excellent) by two additional independent radiologists. Statistical analysis comparing the groups and assessing agreement included intraclass coefficients, Student's t-test and Mann-Whitney U-test. Small bowel distension was not significantly different in any of the five small bowel segments between the use of sorbitol and psyllium as OCAs in both the qualitative (p = 0.338-0.908) and quantitative assessments (p = 0.083-0.856). The mean bowel distension achieved was 20.1 ± 2.2 mm for sorbitol and 19.8 ± 2.5 mm for psyllium (p = 0.722). Visualization of the ileum was good or excellent in 65% of the examinations in both groups. Sorbitol and psyllium are not significantly different at distending the small bowel and both may be used as OCAs for MRE studies. This is the first study to directly compare the degree of distension in MRE between these two common, readily available and inexpensive OCAs.

  14. Plaque control and oral hygiene methods

    LENUS (Irish Health Repository)

    Harrison, Peter

    2017-06-01

    The experimental gingivitis study of Löe et al.1 demonstrated a cause and effect relationship between plaque accumulation and gingival inflammation, and helped to establish plaque\\/biofilm as the primary risk factor for gingivitis. When healthy individuals withdrew oral hygiene efforts, gingival inflammation ensued within 21 days in all subjects. Once effective plaque removal was recommenced, clinical gingival health was quickly re-established – indicating that plaque-associated inflammation is modifiable by plaque control. As current consensus confirms that gingivitis and periodontitis may be viewed as a continuum of disease,2 the rationale for achieving effective plaque control is clear.

  15. Development of a new disintegration method for orally disintegrating tablets.

    Science.gov (United States)

    Kakutani, Ryo; Muro, Hiroyuki; Makino, Tadashi

    2010-07-01

    Recently, the focus has been on the importance of assessing the oral disintegrative properties of orally disintegrating tablets (ODTs). In particular, in the development stages and the quality control field of ODT products, a physical assessment method which easily measures oral disintegrative properties is desired. For this reason, we developed a new disintegration test method (Kyoto-model disintegration method or KYO method), which is useful to predict the oral disintegrative properties of an ODT easily, and examined the availability of the method. In the KYO method, ODT samples were classified in terms of their water permeability, and a moderate water volume was decided. Subsequently, the disintegrative properties were assessed with the newly proposed method. For 25 commercial prescription ODTs used as samples, a good correlation was shown between the results of a human sensory test by five healthy male volunteers and the results using the KYO method. Furthermore, the KYO method could evaluate time-dependent changes in ODT samples. On the other hand, no correlation was observed between the Japanese Pharmacopeia disintegration test and the human sensory test. These results suggested that the KYO method reflected the disintegration nature of the ODTs in the oral cavity, and could easily be applied to development stages and the quality control field of ODT products.

  16. Comparison between computed tomography with oral oil-based contrast and laparotomy for gastric cancer staging; Tomografia computerizada con contraste oral graso frente a lapartomia en la estadificacion del cancer gastrico

    Energy Technology Data Exchange (ETDEWEB)

    Marco, S. F.; Garcia-Vila, J. H.; Cervera, J.; Gomez, R.; Piqueras, R. M.; Perona, I.; Escrig, J.; Salvador, J. L. [Hospital General de Castello. Castellon (Spain)

    2000-07-01

    To compare the utility of conventional computed tomography (CT) with oral oil-based contrast with that of laparotomy in the preoperative staging of gastric cancer. We prospectively studied 41 patients diagnosed as having gastric adenocarcinoma according to the results of endoscopy and biopsy. Applying the TNM classification for gastric cancer staging, we compared the findings in CT associated with oral oil-based contrast and intraoperative staging with definitive postoperative pathological staging. Definitive pathological studies demonstrated that there were 7 stage T1-T2 lesions, 26 stage T3 and 8 stage T4. The assessment of lymph node involvement showed that 10 patients presented stage N0 and 31 stage N1-N3. Ten patients had metastases. The diagnostic reliability for tumor staging according to CT was 56% versus 80% for laparotomy. In the determination of nodal involvement CT had a diagnostic yield of 71% versus 6% for laparotomy. Metastatic disease was correctly diagnosed by CT in 83% of cases versus 88% by laparotomy. There were no statistically significant differences between CT with oral oil-based contrast and laparotomy for the staging of nodal involvement and metastases. However, the CT diagnosis was significantly more reliable than laparotomy for the determination of tumor infiltration. (Author) 21 refs.

  17. Depiction of normal gastrointestinal anatomy with MDCT: comparison of low- and high-attenuation oral contrast media.

    Science.gov (United States)

    Erturk, Sukru Mehmet; Mortelé, Koenraad J; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R

    2008-04-01

    To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Duodenal, jejunal and ileal distention (pcontrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (pcontrast medium, for reader 2. Interobserver agreement was fair to good for both distention (kappa-range: 0.41-0.74) and wall visualization (kappa-range: 0.48-0.71). MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium.

  18. Impact of low-energy CT imaging on selection of positive oral contrast media concentration.

    Science.gov (United States)

    Patino, Manuel; Murcia, Diana J; Iamurri, Andrea Prochowski; Kambadakone, Avinash R; Hahn, Peter F; Sahani, Dushyant V

    2017-05-01

    To determine to what extent low-energy CT imaging affects attenuation of gastrointestinal tract (GIT) opacified with positive oral contrast media (OCM). Second, to establish optimal OCM concentrations for low-energy diagnostic CT exams. One hundred patients (38 men and 62 women; age 62 ± 11 years; BMI 26 ± 5) with positive OCM-enhanced 120-kVp single-energy CT (SECT), and follow-up 100-kVp acquisitions (group A; n = 50), or 40-70-keV reconstructions from rapid kV switching-single-source dual-energy CT (ssDECT) (group B; n = 50) were included. Luminal attenuation from different GIT segments was compared between exams. Standard dose of three OCM and diluted solutions (75%, 50%, and 25% concentrations) were introduced serially in a gastrointestinal phantom and scanned using SECT (120, 100, and 80 kVp) and DECT (80/140 kVp) acquisitions on a ssDECT scanner. Luminal attenuation was obtained on SECT and DECT images (40-70 keV), and compared to 120-kVp scans with standard OCM concentrations. Luminal attenuation was higher on 100-kVp (328 HU) and on 40-60-keV images (410-924 HU) in comparison to 120-kVp scans (298 HU) in groups A and B (p < 0.05). Phantom: There was an inverse correlation between luminal attenuation and X-ray energy, increasing up to 527 HU on low-kVp and 999 HU on low-keV images (p < 0.05). 25% and 50% diluted OCM solutions provided similar or higher attenuation than 120 kVp, at low kVp and keV, respectively. Low-energy CT imaging increases the attenuation of GIT opacified with positive OCM, permitting reduction of 25%-75% OCM concentration.

  19. MDCT appearance of the appendix: how does the low-density barium sulfate oral contrast agent affect it?

    Science.gov (United States)

    Yaghmai, Vahid; Aghaei-Lasboo, Anahita; Brandwein, Warren M; Tochetto, Sandra; Mafi, John N; Miller, Frank H; Nikolaidis, Paul

    2011-01-01

    We compared the effect of low-density barium sulfate neutral oral contrast agent on the diameter of normal appendix and its luminal content versus that of water on multidetector-row CT. CT scans of 24 patients who had been imaged on two separate occasions for the evaluation of pancreatic pathology, once with water and subsequently with low-density barium sulfate as the neutral oral contrast agent were evaluated (total of 48 scans). Studies were randomized and reviewed in consensus on a workstation in the stack mode by two radiologists blinded to the type of oral contrast. The appendix was measured at baseline and 10 days later to obtain an average diameter. Results of the water and low-density barium sulfate groups were compared using paired t test. Contents of the appendiceal lumen were also noted (gas, fluid, mixed, and collapsed appendix). The average diameter of the appendix for scans obtained with water and low-density barium sulfate was 4.09 ± 0.87 mm (median, 4.22 mm; range, 2.50-5.65 mm) and 4.13 ± 0.93 mm (median, 4 mm, range, 2.2-5.65 mm), respectively. This difference was not statistically significant (P = 0.69). There was no statistically significant difference in the appendiceal content when water or low-density barium sulfate were used as oral contrast (χ (2) = 4.25, P = 0.89). Low-density barium sulfate does not affect appendiceal content or diameter and, therefore, should not adversely affect evaluation of the appendix on multidetector row CT.

  20. Repeatability of oral fluid collection methods for THC measurement

    NARCIS (Netherlands)

    Houwing, Sjoerd; Smink, Beitske E.; Legrand, Sara-Ann; Mathijssen, Rene P. M.; Verstraete, Alain G.; Brookhuis, Karel A.

    2012-01-01

    Study objectives: To determine the influence of sample collection for two different collection methods on THC concentrations and to compare THC concentrations collected by both methods. Methods: A total of 136 pairs of oral fluid samples from subjects who had recently smoked Cannabis were obtained

  1. A new manganese-based oral contrast agent (CMC-001) for liver MRI. Pharmacological and pharmaceutical aspects

    International Nuclear Information System (INIS)

    Joergensen, Jan Troest; Rief, Matthias; Wagner, Moritz; Brismar, Torkel B.; Albiin, Nils

    2012-01-01

    Manganese is one of the most abundant metals on earth and is found as a component of more than 100 different minerals. Besides being an essential trace element in relation to the metabolic processes in the body, manganese is also a paramagnetic metal that possesses similar characteristics to gadolinium with regards to T1-weighted (T1-w) magnetic resonance imaging (MRI). Manganese, in the form of manganese (II) chloride tetrahydrate, is the active substance in a new targeted oral contrast agent, currently known as CMC-001, indicated for hepatobiliary MRI. Under physiological circumstances manganese is poorly absorbed from the intestine after oral intake, but by the use of specific absorption promoters, L-alanine and vitamin D3, it is possible to obtain a sufficiently high concentration in the liver in order to achieve a significant signal enhancing effect. In the liver manganese is exposed to a very high first-pass effect, up to 98 %, which prevents the metal from reaching the systemic circulation, thereby reducing the number of systemic side-effects. Manganese is one of the least toxic trace elements, and due to its favorable safety profile it may be an attractive alternative to gadolinium-based contrast agents for patients undergoing an MRI evaluation for liver metastases in the future. In this review the basic pharmacological and pharmaceutical aspects of this new targeted oral hepatobiliary specific contrast agent will be discussed

  2. Reducing the oral contrast dose in CT colonography: evaluation of faecal tagging quality and patient acceptance

    International Nuclear Information System (INIS)

    Liedenbaum, M.H.; Denters, M.J.; Zijta, F.M.; Ravesteijn, V.F. van; Bipat, S.; Vos, F.M.; Dekker, E.; Stoker, J.

    2011-01-01

    Aim: To evaluate the minimal iodine contrast medium load necessary for an optimal computed tomography colonography tagging quality. Materials and Methods: Faecal occult blood test positive patients were randomly selected for one of three iodine bowel preparations: (1) 3 x 50 ml meglumine ioxithalamate (45 g iodine), (2) 4 x 25 ml meglumine ioxithalamate (30 g iodine); or (3) 3 x 25 ml (22.5 g iodine) meglumine ioxithalamate. Two experienced readers assessed the tagging quality per colonic segment on a five-point scale and the presence of adherent stool. Also semi-automatic homogeneity measurements were performed. Patient acceptance was assessed with questionnaires. Results: Of 70 eligible patients, 45 patients participated (25 males, mean age 62 years). Each preparation group contained 15 patients. The quality of tagging was insufficient (score 1-2) in 0% of segments in group 1; 4% in group 2 (p < 0.01 versus group 1); and 5% in group 3 (p = 0.06 versus group 1). In group 1 in 11% of the segments adherent stool was present compared with 49% in group 2 and 41% in group 3 (p < 0.01, group 2 and 3 versus group 1). Homogeneity was 85, 102 (p < 0.01), and 91 SD HU (p = 0.26) in groups 1, 2, and 3, respectively. In group 1 two patients experienced no burden after contrast agent ingestion compared to one patient in group 2 and nine patients in group 3 (p = 0.017). Conclusion: A dose of 3 x 50 ml meglumine ioxithalamate is advisable for an optimal tagging quality despite beneficial effects on the patient acceptance in patients receiving a lower dose.

  3. Repeatability of oral fluid collection methods for THC measurement.

    NARCIS (Netherlands)

    Houwing, S. Smink, B.E. Legrand, S.-A. Mathijssen, M.P.M. Verstraete, A.G. & Brookhuis, K.A.

    2013-01-01

    The study objective was to determine the influence of sample collection for two different collection methods on THC concentrations and to compare THC concentrations collected by both methods. A total of 136 pairs of oral fluid samples from subjects who had recently smoked Cannabis were obtained by

  4. High-contrast resolution of film-screen systems in oral and maxillofacial radiology

    International Nuclear Information System (INIS)

    Kaeppler, G.; Reinert, S.

    2007-01-01

    Purpose: The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same X-ray units as those used for patient radiographs. Materials and methods: The MTF was determined using a lead grid and according to DIN 6867 - 2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. Results: With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). (orig.)

  5. CT of the pancreas with a fat-density oral contrast medium

    International Nuclear Information System (INIS)

    Raptopoulos, V.; Davidoff, A.; Davis, M.A.; Coolbaugh, B.L.; Smith, E.H.

    1987-01-01

    Visualization of the head of the pancreas on CT was evaluated in three groups, each consisting of 100 patients without pancreatic pathology who received a fat-density oral preparation. The corn oil emulsion was tolerated well by the patients and allowed consistently superior discrimination of the head of the pancreas from the duodenal C-loop as compared to the other two control groups. A score was developed for the CT discrimination of duodenum from pancreas. The average score for corn oil emulsion was .94, as opposed to .74 for the high-density agents and .76 for patients who did not receive any oral preparation. Until further experience is acquired, the authors do not recommend the use of corn oil in patients thought to have pancreatic pseudocysts or abscesses. In addition, the use of fat-containing oral agents may be contraindicated in patients with acute pancreatitis. For routine CT evaluation of the pancreas and upper abdomen, the authors consider corn oil emulsion superior to the other oral regimens

  6. Research on a new oral contrast agent for abdominal MRI using free manganese ion

    International Nuclear Information System (INIS)

    Hasegawa, Hideo; Fujita, Osamu; Hiraishi, Kumiko; Narabayashi, Isamu; Komba, Toshinori; Hamamura, Yoshinori.

    1996-01-01

    Manganese chloride (Mn: 3 mg/100 g) aqueous solution with hydragenated oligosaccharide and xanthan gum (T 1 : 0.1 sec, T 2 : 0.03 sec at 0.5T) functions in gut as a positive contrast agent on MR T 1 -weighted images and a low signal component on MR T 2 -weighted images. The manganese in the solution functions as a contrast agent under free manganese ion (Mn 2+ ). Further, the solution has special characteristics in terms of MRI signal intensity and relaxation time that are equal to those of blueberry juice, which performs as an effective contrast agent on T 1 -and T 2 -weighted images, and functions as a contrast agent in vitro and in vivo. (author)

  7. DNA Checkerboard Method for Bacterial Pathogen Identification in Oral Diseases

    OpenAIRE

    Nascimento, Cássio do; Issa, João Paulo Mardegan; Watanabe, Evandro; Ito, Izabel Yoko

    2006-01-01

    This work aim to show by literature review the principal characteristics of the DNA checkerboard method for bacterial pathogens identification in oral diseases, showing the most varieties uses and applications of this technique Este trabajo tiene como objetivo, presentar en una revisión de la literatura, las principales características del método de chequeo del DNA para la identificación de bacterias patógenas en la cavidad oral, mostrando las diferentes utilizaciones y aplicaciones de est...

  8. SU-F-P-29: Impact of Oral Contrast Agent for Assisting in Outlining Small Intestine On Pelvic IMAT Dose in Patients with Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, R; Bai, W; Fan, X [The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei (China)

    2016-06-15

    Purpose: As the advanced intensity modulated arc therapy(IMAT) delivery systems becoming a main role of treatment ways, which places even greater demands on delivering accuracy. The impact of oral contrast agent (meglumine diatrizoate) for assisting in outlining the small intestine on pelvic IMAT dose in patients with cervical cancer was investigated. Methods: Ten cervical cancer patients for postoperative radiotherapy underwent CT scans, and the planning target volumes (PTV) and organs at risk (including the small intestine, rectum, bladder, colon and the left and right femoral head) were contoured. The IMAT plans were generated on Oncentra v4.1 planning system for each case, PTV was prescribed to 50.4 Gy in 28 fractions. Then another plan was generated by re-calculating the radiation dose after changing the electron density of the small bowel. The first plan (plan A) was the conventional IMAT plan (with oral contrast agent), and the second one (plan B) specified the electron density of the small bowel (without oral contrast agent). Paired t-test was used to compare the dose distribution between the two plans. Results: The PTV’s D2, D50, D95, V110, conformity index, and homogeneity index of plans A and B were 5610.5 vs. 5611.4 cGy (P=0.175), 5348.5 vs. 5348.0 cGy (P=0.869), 5039 vs. 5042.3 (P=0.518), 6.0% vs. 6.1 %( P=0.886), 0.1269 vs. 0.1271 (P=0.34) and 0.8421 vs. 0.8416 (P=0.598), respectively. The volumes of the small bowel receiving at least 30 Gy (V30) and the minimum dose of 2% volume accepted (D2) for plans A and B were 31.6% vs. 31.9% (P=0.371) and 5067.8 vs. 5085.4 cGy (P=0.377), while rectum V50 of the two plans was 12.4% vs. 12.1% (P=0.489). Conclusion: The oral contrast agent (meglumine diatrizoate) filling the small intestine does not lead to a significant increase in the pelvic IMAT dose in patients with cervical cancer.

  9. Lecithine as an adjuvant in resorption of contrast medium in oral cholecystography

    International Nuclear Information System (INIS)

    Lindgren, I.

    1978-01-01

    No or poor filling of the gallbladder was obtained in 21 patients at cholecystography. They were re-examined after 10 days or later with the addition of lecithine to the contrast medium. The filling of the gallbladder, which was without abnormality, was improved in all cases. The mechanism of this effect is discussed. (Auth.)

  10. Contrasting effects of cord injury on intravenous and oral pharmacokinetics of diclofenac: a drug with intermediate hepatic extraction.

    Science.gov (United States)

    Cruz-Antonio, L; Arauz, J; Franco-Bourland, R E; Guízar-Sahagún, G; Castañeda-Hernández, G

    2012-08-01

    Laboratory investigation in rats submitted to experimental spinal cord injury (SCI). To determine the effect of acute SCI on the pharmacokinetics of diclofenac, a marker drug of intermediate hepatic extraction, administered by the intravenous and the oral routes. Female Wistar rats were submitted to complete section of the spinal cord at the T8 level. SCI and sham-injured rats received 3.2 mg kg(-1) of diclofenac sodium either intravenously or orally, diclofenac concentration was measured in whole blood samples and pharmacokinetic parameters were estimated. Diclofenac was not selected as test drug because of its therapeutic properties, but because to its biopharmaceutical properties, that is, intermediate hepatic extraction. Diclofenac bioavailability after intravenous administration was increased in injured rats compared with controls due to a reduced clearance. In contrast, oral diclofenac bioavailability was diminished in SCI animals due to a reduction in drug absorption, which overrides the effect on clearance. Acute SCI induces significant pharmacokinetic changes for diclofenac, a marker drug with intermediate hepatic extraction. SCI-induced pharmacokinetic changes are not only determined by injury characteristics, but also by the route of administration and the biopharmaceutical properties of the studied drug.

  11. Evaluation of tumor invasion in gastric carcinoma with CT using water as an oral contrast agent in prone position

    International Nuclear Information System (INIS)

    Chung, Jin Il; Lee, Jong Tae; Yoo, Hyung Sik; Lee, Byung Hee; Bae, Jong Yup

    1994-01-01

    To evaluate the accuracy of CT using water as an oral contrast material in a prone position in determining the depth of tumor invasion in gastric cancer patients. Thirty three patients(19 male, 14 female) with surgically confirmed gastric cancer were studied. We performed CT in a prone position after ingestion of 1 liter of pure water. CT findings were classified into 4 groups by the morphologic appearance of infiltrates in the perigastric fat plane: normal perigastric fat(S0), fine mottled densities(S1), irregular aggregated or liner densities(S2) and direct extension and invasion of tumor into contiguous structures(S3). Also we prospectively compared the CT staging with pathologic T staging according to the TNM systems. The overall accuracy of CT staging in determining the pathologic T factor was 69.6%. As we regarded T1 and T2 lesions as one group on CT, the accuracy of CT staging was increased to 80.2% because of a limitation of CT for distinguishing T1 from T2 lesions. Prone position CT using water as an oral contrast agent is quite accurate in determining the T staging of gastric carcinoma

  12. Oral contrast media for the magnetic resonance tomography of the abdomen. Pt. 3

    International Nuclear Information System (INIS)

    Claussen, C.; Kornmesser, W.; Laniado, M.; Kaminsky, S.; Hamm, B.; Felix, R.; Klinikum Steglitz, Berlin

    1988-01-01

    32 patients with abdominal tumours or inflammatory abdominal diseases were examined by MRI (0.5 T) prior to and after oral administration of gadolinium-DTPA (Gd-DTPA). T 1 - and T 2 -weighted sequences were employed. 10 ml/kg body weight of a Gd-DTPA formulation were administered (1.0 mmol/l, 1.5 g mannitol/l). Gd-DTPA provided markedly hyperintensive opacification of the gastro-intestinal tract. In 19 of 32 studies Gd-DTPA-enhanced scans showed improved delineation of abdominal pathologies. In most cases Gd-DTPA-enhanced T 1 -weighted multi-slice gradient echo images provided the most useful diagnostic result. Meteorism and diarrhoe were recorded in 13 patients. (orig.) [de

  13. Comparative study of protoporphyrin IX fluorescence image enhancement methods to improve an optical imaging system for oral cancer detection

    Science.gov (United States)

    Jiang, Ching-Fen; Wang, Chih-Yu; Chiang, Chun-Ping

    2011-07-01

    Optoelectronics techniques to induce protoporphyrin IX fluorescence with topically applied 5-aminolevulinic acid on the oral mucosa have been developed to noninvasively detect oral cancer. Fluorescence imaging enables wide-area screening for oral premalignancy, but the lack of an adequate fluorescence enhancement method restricts the clinical imaging application of these techniques. This study aimed to develop a reliable fluorescence enhancement method to improve PpIX fluorescence imaging systems for oral cancer detection. Three contrast features, red-green-blue reflectance difference, R/B ratio, and R/G ratio, were developed first based on the optical properties of the fluorescence images. A comparative study was then carried out with one negative control and four biopsy confirmed clinical cases to validate the optimal image processing method for the detection of the distribution of malignancy. The results showed the superiority of the R/G ratio in terms of yielding a better contrast between normal and neoplastic tissue, and this method was less prone to errors in detection. Quantitative comparison with the clinical diagnoses in the four neoplastic cases showed that the regions of premalignancy obtained using the proposed method accorded with the expert's determination, suggesting the potential clinical application of this method for the detection of oral cancer.

  14. Computer-Based Oral Hygiene Instruction versus Verbal Method in Fixed Orthodontic Patients

    Science.gov (United States)

    Moshkelgosha, V.; Mehrvarz, Sh.; Saki, M.; Golkari, A.

    2017-01-01

    Statement of Problem: Fixed orthodontic appliances in the oral cavity make tooth cleaning procedures more complicated. Objectives: This study aimed to compare the efficacy of computerized oral hygiene instruction with verbal technique among fixed orthodontic patients referred to the evening clinic of Orthodontics of Shiraz Dental School. Materials and Methods: A single-blind study was performed in Orthodontic Department of Shiraz, Islamic Republic of Iran, from January to May 2015 following the demonstrated exclusion and inclusion criteria. The sample size was considered 60 patients with 30 subjects in each group. Bleeding on probing and plaque indices and dental knowledge were assessed in the subjects to determine pre-intervention status. A questionnaire was designed for dental knowledge evaluation. The patients were randomly assigned into the computerized and verbal groups. Three weeks after the oral hygiene instruction, indices of bleeding on probing and plaque index and the dental knowledge were evaluated to investigate post-intervention outcome. The two groups were compared by chi-square and student t tests. The pre- and post-intervention scores in each group were compared using paired t-test. Results: In the computerized group, the mean score for plaque index and bleeding on probing index was significantly decreased while dental health knowledge was significantly increased after oral hygiene instruction, in contrast to the verbal group. Conclusions: Within the limitations of the current study, computerized oral hygiene instruction is proposed to be more effective in providing optimal oral health status compared to the conventional method in fixed orthodontic patients. PMID:28959765

  15. Comparison of identification methods for oral asaccharolytic Eubacterium species.

    Science.gov (United States)

    Wade, W G; Slayne, M A; Aldred, M J

    1990-12-01

    Thirty one strains of oral, asaccharolytic Eubacterium spp. and the type strains of E. brachy, E. nodatum and E. timidum were subjected to three identification techniques--protein-profile analysis, determination of metabolic end-products, and the API ATB32A identification kit. Five clusters were obtained from numerical analysis of protein profiles and excellent correlations were seen with the other two methods. Protein profiles alone allowed unequivocal identification.

  16. Fundamental studies of oral contrast agents for MR. Comparison of manganese agent and iron agent

    International Nuclear Information System (INIS)

    Fujita, Osamu; Hiraishi, Kumiko; Suginobu, Yoshito; Takeuchi, Masayasu; Narabayashi, Isamu

    1996-01-01

    We investigated and compared signal intensity and the effect of imaging the upper abdomen with blueberry juice (B.J.), a Mn agent utilizing the properties of paramagnetic metals, and FerriSeltz (F.S.), an iron agent. Since the relaxation effect was much stronger with B.J. than with F.S., the signal intensity required of a peroral contrast agent was able to be obtained at a much lower concentration of B.J. In imaging the upper abdomen, B.J. had a positive effect on imaging in T1-weighted images, and a negative effect in T2-weighted images. F.S. had a positive imaging effect in both, and because it showed extremely high signals in T2-weighted images, motion artifact arose. (author)

  17. An oral modified-release nifedipine tablet (Adalat LA) and its appearance on double contrast barium enema

    International Nuclear Information System (INIS)

    Bleehen, Robert E.

    2000-01-01

    Adalat LA 30 mg and 60 mg tablets are widely prescribed oral modified release nifedipine preparations with a porous, non-digestible plastic tablet coating which is required in order to effect the osmotically driven slow release mechanism. These tablets may therefore be seen anywhere along the gastrointestinal tract and are passed apparently whole in the faeces. An example of the appearance within the rectum of Adalat LA 30 (Bayer) on double contrast barium enema is shown and the main features described. A review of the literature is given. Recognition of the appearances during the barium enema examination will prompt those performing the procedure to question the drug history where relevant and will reduce the incidence of false-positive reporting. Bleehen, R.E. (2000)

  18. Comparative effectiveness of instructional methods: oral and pharyngeal cancer examination.

    Science.gov (United States)

    Clark, Nereyda P; Marks, John G; Sandow, Pamela R; Seleski, Christine E; Logan, Henrietta L

    2014-04-01

    This study compared the effectiveness of different methods of instruction for the oral and pharyngeal cancer examination. A group of thirty sophomore students at the University of Florida College of Dentistry were randomly assigned to three training groups: video instruction, a faculty-led hands-on instruction, or both video and hands-on instruction. The training intervention involved attending two sessions spaced two weeks apart. The first session used a pretest to assess students' baseline didactic knowledge and clinical examination technique. The second session utilized two posttests to assess the comparative effectiveness of the training methods on didactic knowledge and clinical technique. The key findings were that students performed the clinical examination significantly better with the combination of video and faculty-led hands-on instruction (p<0.01). All students improved their clinical exam skills, knowledge, and confidence in performing the oral and pharyngeal cancer examination independent of which training group they were assigned. Utilizing both video and interactive practice promoted greater performance of the clinical technique on the oral and pharyngeal cancer examination.

  19. Multi-detector CT urography: effect of oral hydration and contrast medium volume on renal parenchymal enhancement and urinary tract opacification - a quantitative and qualitative analysis

    International Nuclear Information System (INIS)

    Szolar, Dieter H.; Tillich, Manfred; Preidler, Klaus W.

    2010-01-01

    To assess the effect of oral hydration and contrast-medium volume on renal enhancement and urinary tract opacification in multi-detector CT urography. A total of 192 patients were assigned to different protocols with varying doses of contrast agent with and without oral hydration. The attenuation was measured in the renal parenchyma in the unenhanced, nephrographic and excretory phase, and in the urinary tract in excretory phase imaging, respectively. Opacification of the urinary tract was graded on volume rendered images. Oral hydration did not significantly alter renal parenchymal enhancement in both the nephrographic and the excretory phase (p > 0.001), but significantly decreased mean attenuation of the urinary tract in the excretory phase (p ≤ 0.001), and improved continuous opacification of all ureter segments (p < 0.01). Higher volumes of contrast medium improved renal parenchymal enhancement (p ≤ 0.001) and continuous opacification of the urinary tract (p ≤ 0.01). Oral hydration leads to lower attenuation values in the urinary tract but improves the continuous opacification of the tract. Increase in contrast medium volume leads to higher renal parenchymal enhancement as well as to an increased continuous opacification of the urinary tract. Decrease in contrast medium volume cannot be compensated for by oral hydration in terms of parenchymal enhancement. (orig.)

  20. [High-contrast resolution of film-screen systems in oral and maxillofacial radiology].

    Science.gov (United States)

    Kaeppler, G; Reinert, S

    2007-11-01

    The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same x-ray units as those used for patient radiographs. The MTF was determined using a lead grid and according to DIN 6867-2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). The relevance of this study is underlined by the diagnostic reference doses defined in the German X-ray Ordinance (RöV) which are also intended for dentistry. Film-screen systems (speed 250, speed class 200) previously used in dental panoramic and cephalometric radiography can be replaced by newly developed film-screen systems (speed class 400). In dental radiography dose reductions are possible with film-screen systems (speed class 400) without impairing diagnostic accuracy. The introduction of newly developed film-screen systems (speed class 400) requires lower milliampere-seconds and therefore an adjustment of the x-ray units to lower milliampere settings.

  1. Does MRI with oral contrast medium allow single-study depiction of inflammatory bowel disease enteritis and colitis?

    International Nuclear Information System (INIS)

    Cronin, Carmel G.; Lohan, Derek G.; Browne, Ann Michelle; Roche, Clare; Murphy, Joseph M.

    2010-01-01

    To assess the feasibility and utility of magnetic resonance (MR) imaging of the bowel in concurrent small- and large-bowel evaluation for the presence of inflammatory bowel disease (IBD). Over a 5-year period, 62 MR examinations performed on 53 patients demonstrated evidence of IBD. Sixteen of these 53 (30.1%) patients had imaging findings of colonic disease and underwent 19 formal MR small bowel examinations. These were further evaluated for bowel distention and image quality. The sensitivity and specificity of the technique compared with colonoscopy as the 'gold standard' was evaluated. Simultaneous imaging of the colon is feasible at MR small bowel follow-through with moderate-to-excellent colonic visibility and colon distention obtained when the contrast medium is present in the colon at the time of image acquisition. MR imaging had a sensitivity of 80% (0.56-0.93), specificity of 100% (0.77-1.00), positive predictive value (PPV) of 1 and a negative predictive value (NPV) of 0.8 for the identification of colitis (based on available concurrent correlation of 38/62 examinations with colonoscopy). Small and large bowel MR imaging with orally consumed contrast medium represents a promising, feasible, non-invasive, non-radiating single mode of assessment of the entire gastrointestinal tract, performed at a single sitting. (orig.)

  2. Oral contrast agents for small bowel distension in MRI: influence of the osmolarity for small bowel distention

    International Nuclear Information System (INIS)

    Ajaj, Waleed; Kuehle, Christiane; Nuefer, Michael; Goehde, Susanne C.; Lauenstein, Thomas C.; Goyen, Mathias; Schneemann, Hubert; Ruehm, Stefan G.

    2005-01-01

    To assess the effect of the osmolarity for small bowel distension in MRI, ten volunteers ingested at two separate occasions negative oral contrast agents with different quantity and osmolarity: (1) a water solution combined with 2.0% sorbitol and 0.2% locus bean gum (LBG) with a quantity of 1500 ml and an osmolarity of 148 mOsmol/l, (2) a water solution combined with 2.0% sorbitol and 2.0% barium sulphate with a quantity of 1000 ml and an osmolarity of 194 mOsmol/l. Small bowel distension was quantified on coronal 2D-TrueFISP images by measuring the small bowel diameters. There were no statistically significant differences in mean small bowel diameter between both contrast agents. The mean small bowel distension was 19.2 mm after ingestion of 1500 ml of sorbitol-LBG solution and 19.0 mm after ingestion of 1000-ml sorbitol-barium sulphate solution. Furthermore, all volunteers found the ingestion of 1000-ml solution more pleasant than the 1500-ml solution. The ingestion of 1000 ml of sorbitol-barium sulphate solution led to a sufficient small bowel distension compared to 1500 ml of sorbitol-LBG solution. The side effect rate of both solutions was low. Based on these data, we recommend a quantity of 1000 ml of sorbitol-barium sulphate solution as an alternative for 1500-ml sorbitol-LBG solution for optimal bowel distension. (orig.)

  3. Enhancement effects of test injection with a small amount of MR contrast medium in the oral and maxillofacial region

    International Nuclear Information System (INIS)

    Yanagi, Yoshinobu; Asaumi, Jun-ichi; Konouchi, Hironobu; Hisatomi, Miki; Matsuzaki, Hidenobu; Murakami, Jun; Maki, Yuu; Unetsubo, Teruhisa; Kishi, Kanji

    2006-01-01

    Purpose: To examine whether the signal intensity of dynamic contrast-enhanced MRI (DCE-MRI) is altered by test injection of 1 ml of contrast medium, and if so, whether this change affects the DCE-MRI analysis. Materials and methods: Six healthy volunteers were examined by DCE-MRI using a Magnevist syringe and/or an Omniscan syringe for the injection of contrast medium. Each scan was performed 10 times using steady-state free precession (3D-FISP), a sequence for DCE-MRI, before and after intravenous injection of 1 ml of the contrast medium. The internal pterygoid muscle, masseter muscle, tongue, parotid gland, submandibular gland, bone marrow of the mandible, subcutaneous adipose tissue, and common carotid artery were determined to be regions of interest (ROI), and the ROI internal average signal intensity was measured. The 10 data sets obtained before or after contrast medium administration for each ROI were evaluated using the paired t-test. Results: The test injection increased the signal intensities of six of eight ROIs, with all 20 experiments in the submandibular gland showing significant differences. There was no significant difference in the two ROIs corresponding to the carotid artery and subcutaneous adipose tissue of the cheek. Conclusions: The enhanced signal intensity in the tissue might have been caused by the small amount of contrast medium in the test injection. To eliminate this discrepancy caused by the test injection, a pre-contrast scan should be performed when the average signal intensity of an ROI is measured. We therefore believe that the data obtained before a test injection may be important in the analysis of DCE-MRI

  4. Evaluation of Laser Speckle Contrast Imaging for the Assessment of Oral Mucosal Blood Flow following Periodontal Plastic Surgery: An Exploratory Study.

    Science.gov (United States)

    Molnár, Eszter; Molnár, Bálint; Lohinai, Zsolt; Tóth, Zsuzsanna; Benyó, Zoltán; Hricisák, Laszló; Windisch, Péter; Vág, János

    2017-01-01

    The laser speckle contrast imaging (LSCI) is proved to be a reliable tool in flap monitoring in general surgery; however, it has not been evaluated in oral surgery yet. We applied the LSCI to compare the effect of a xenogeneic collagen matrix (Geistlich Mucograft®) to connective tissue grafts (CTG) on the microcirculation of the modified coronally advanced tunnel technique (MCAT) for gingival recession coverage. Gingival microcirculation and wound fluid were measured before and after surgery for six months at twenty-seven treated teeth. In males, the flap microcirculation was restored within 3 days for both grafts followed by a hyperemic response. During the first 8 days the blood flow was higher at xenogeneic graft comparing to the CTG. In females, the ischemic period lasted for 7-12 days depending on the graft and no hyperemic response was observed. Females had more intense and prolonged wound fluid production. The LSCI method is suitable to capture the microcirculatory effect of the surgical intervention in human oral mucosa. The application of xenogeneic collagen matrices as a CTG substitute does not seem to restrain the recovery of graft bed circulation. Gender may have an effect on postoperative circulation and inflammation.

  5. A novel method for delineation of oral mucosa for radiotherapy dose–response studies

    International Nuclear Information System (INIS)

    Dean, Jamie A.; Welsh, Liam C.; Gulliford, Sarah L.; Harrington, Kevin J.; Nutting, Christopher M.

    2015-01-01

    There is currently no standard method for delineating the oral mucosa and most attempts are oversimplified. A new method to obtain anatomically accurate contours of the oral mucosa surfaces was developed and applied to 11 patients. This is expected to represent an opportunity for improved toxicity modelling of oral mucositis

  6. Dual Contrast CT Method Enables Diagnostics of Cartilage Injuries and Degeneration Using a Single CT Image.

    Science.gov (United States)

    Saukko, Annina E A; Honkanen, Juuso T J; Xu, Wujun; Väänänen, Sami P; Jurvelin, Jukka S; Lehto, Vesa-Pekka; Töyräs, Juha

    2017-12-01

    Cartilage injuries may be detected using contrast-enhanced computed tomography (CECT) by observing variations in distribution of anionic contrast agent within cartilage. Currently, clinical CECT enables detection of injuries and related post-traumatic degeneration based on two subsequent CT scans. The first scan allows segmentation of articular surfaces and lesions while the latter scan allows evaluation of tissue properties. Segmentation of articular surfaces from the latter scan is difficult since the contrast agent diffusion diminishes the image contrast at surfaces. We hypothesize that this can be overcome by mixing anionic contrast agent (ioxaglate) with bismuth oxide nanoparticles (BINPs) too large to diffuse into cartilage, inducing a high contrast at the surfaces. Here, a dual contrast method employing this mixture is evaluated by determining the depth-wise X-ray attenuation profiles in intact, enzymatically degraded, and mechanically injured osteochondral samples (n = 3 × 10) using a microCT immediately and at 45 min after immersion in contrast agent. BiNPs were unable to diffuse into cartilage, producing high contrast at articular surfaces. Ioxaglate enabled the detection of enzymatic and mechanical degeneration. In conclusion, the dual contrast method allowed detection of injuries and degeneration simultaneously with accurate cartilage segmentation using a single scan conducted at 45 min after contrast agent administration.

  7. Reducing charging effects in scanning electron microscope images by Rayleigh contrast stretching method (RCS).

    Science.gov (United States)

    Wan Ismail, W Z; Sim, K S; Tso, C P; Ting, H Y

    2011-01-01

    To reduce undesirable charging effects in scanning electron microscope images, Rayleigh contrast stretching is developed and employed. First, re-scaling is performed on the input image histograms with Rayleigh algorithm. Then, contrast stretching or contrast adjustment is implemented to improve the images while reducing the contrast charging artifacts. This technique has been compared to some existing histogram equalization (HE) extension techniques: recursive sub-image HE, contrast stretching dynamic HE, multipeak HE and recursive mean separate HE. Other post processing methods, such as wavelet approach, spatial filtering, and exponential contrast stretching, are compared as well. Overall, the proposed method produces better image compensation in reducing charging artifacts. Copyright © 2011 Wiley Periodicals, Inc.

  8. Surface zwitterionization: Effective method for preventing oral bacterial biofilm formation on hydroxyapatite surfaces

    Science.gov (United States)

    Lee, Myoungjin; Kim, Heejin; Seo, Jiae; Kang, Minji; Kang, Sunah; Jang, Joomyung; Lee, Yan; Seo, Ji-Hun

    2018-01-01

    In this study, we conducted surface zwitterionization of hydroxyapatite (HA) surfaces by immersing them in the zwitterionic polymer solutions to provide anti-bacterial properties to the HA surface. Three different monomers containing various zwitterionic groups, i.e., phosphorylcholine (PC), sulfobetaine (SB), and carboxybetaine (CB), were copolymerized with the methacrylic monomer containing a Ca2+-binding moiety, using the free radical polymerization method. As a control, functionalization of the copolymer containing the Ca2+-binding moiety was synthesized using a hydroxy group. The stable immobilization of the zwitterionic functional groups was confirmed by water contact angle analysis and X-ray photoelectron spectroscopy (XPS) measurement conducted after the sonication process. The zwitterionized HA surface showed significantly decreased protein adsorption, whereas the hydroxyl group-coated HA surface showed limited efficacy. The anti-bacterial adhesion property was confirmed by conducting Streptococcus mutans (S. mutans) adhesion tests for 6 h and 24 h. When furanone C-30, a representative anti-quorum sensing molecule for S. mutans, was used, only a small amount of bacteria adhered after 6 h and the population did not increase after 24 h. In contrast, zwitterionized HA surfaces showed almost no bacterial adhesion after 6 h and the effect was retained for 24 h, resulting in the lowest level of oral bacterial adhesion. These results confirm that surface zwitterionization is a promising method to effectively prevent oral bacterial adhesion on HA-based materials.

  9. Laser Raman detection for oral cancer based on a Gaussian process classification method

    International Nuclear Information System (INIS)

    Du, Zhanwei; Yang, Yongjian; Bai, Yuan; Wang, Lijun; Zhang, Chijun; Chen, He; Luo, Yusheng; Su, Le; Chen, Yong; Li, Xianchang; Zhou, Xiaodong; Shen, Aiguo; Hu, Jiming; Jia, Jun

    2013-01-01

    Oral squamous cell carcinoma is the most common neoplasm of the oral cavity. The incidence rate accounts for 80% of total oral cancer and shows an upward trend in recent years. It has a high degree of malignancy and is difficult to detect in terms of differential diagnosis, as a consequence of which the timing of treatment is always delayed. In this work, Raman spectroscopy was adopted to differentially diagnose oral squamous cell carcinoma and oral gland carcinoma. In total, 852 entries of raw spectral data which consisted of 631 items from 36 oral squamous cell carcinoma patients, 87 items from four oral gland carcinoma patients and 134 items from five normal people were collected by utilizing an optical method on oral tissues. The probability distribution of the datasets corresponding to the spectral peaks of the oral squamous cell carcinoma tissue was analyzed and the experimental result showed that the data obeyed a normal distribution. Moreover, the distribution characteristic of the noise was also in compliance with a Gaussian distribution. A Gaussian process (GP) classification method was utilized to distinguish the normal people and the oral gland carcinoma patients from the oral squamous cell carcinoma patients. The experimental results showed that all the normal people could be recognized. 83.33% of the oral squamous cell carcinoma patients could be correctly diagnosed and the remaining ones would be diagnosed as having oral gland carcinoma. For the classification process of oral gland carcinoma and oral squamous cell carcinoma, the correct ratio was 66.67% and the erroneously diagnosed percentage was 33.33%. The total sensitivity was 80% and the specificity was 100% with the Matthews correlation coefficient (MCC) set to 0.447 213 595. Considering the numerical results above, the application prospects and clinical value of this technique are significantly impressive. (letter)

  10. Laser Raman detection for oral cancer based on a Gaussian process classification method

    Science.gov (United States)

    Du, Zhanwei; Yang, Yongjian; Bai, Yuan; Wang, Lijun; Zhang, Chijun; Chen, He; Luo, Yusheng; Su, Le; Chen, Yong; Li, Xianchang; Zhou, Xiaodong; Jia, Jun; Shen, Aiguo; Hu, Jiming

    2013-06-01

    Oral squamous cell carcinoma is the most common neoplasm of the oral cavity. The incidence rate accounts for 80% of total oral cancer and shows an upward trend in recent years. It has a high degree of malignancy and is difficult to detect in terms of differential diagnosis, as a consequence of which the timing of treatment is always delayed. In this work, Raman spectroscopy was adopted to differentially diagnose oral squamous cell carcinoma and oral gland carcinoma. In total, 852 entries of raw spectral data which consisted of 631 items from 36 oral squamous cell carcinoma patients, 87 items from four oral gland carcinoma patients and 134 items from five normal people were collected by utilizing an optical method on oral tissues. The probability distribution of the datasets corresponding to the spectral peaks of the oral squamous cell carcinoma tissue was analyzed and the experimental result showed that the data obeyed a normal distribution. Moreover, the distribution characteristic of the noise was also in compliance with a Gaussian distribution. A Gaussian process (GP) classification method was utilized to distinguish the normal people and the oral gland carcinoma patients from the oral squamous cell carcinoma patients. The experimental results showed that all the normal people could be recognized. 83.33% of the oral squamous cell carcinoma patients could be correctly diagnosed and the remaining ones would be diagnosed as having oral gland carcinoma. For the classification process of oral gland carcinoma and oral squamous cell carcinoma, the correct ratio was 66.67% and the erroneously diagnosed percentage was 33.33%. The total sensitivity was 80% and the specificity was 100% with the Matthews correlation coefficient (MCC) set to 0.447 213 595. Considering the numerical results above, the application prospects and clinical value of this technique are significantly impressive.

  11. Water-equivalent oral contrast agents in dual-modality PET/computed tomography scanning: does a little barium make the difference?

    Science.gov (United States)

    Kinner, Sonja; Veit-Haibach, Patrick; Lauenstein, Thomas C; Bockisch, Andreas; Antoch, Gerald

    2009-03-01

    To retrospectively evaluate the performance of two water-equivalent oral contrast agents [locust bean gum (LBG)-mannitol and VoLumen] concerning their potential to distend the bowel while avoiding contrast-associated artifacts in PET/computed tomography. PET/computed tomography examinations of 30 patients with two different oral contrast agents were reviewed. Bowel distension, intraluminal density, and potential contrast-associated artifacts were assessed for stomach, jejunum, and ileum. Statistical significance was tested by Student's t-test. Distension was slightly better in the stomach with VoLumen as compared with LBG-mannitol whereas LBG-mannitol was found to slightly better distend the small bowel. This difference proved to be statistically significant for the jejunum. A statistically significant difference was detected for intraluminal density with higher densities for VoLumen. This difference, however, did not result in a higher incidence of PET artifacts with VoLumen. LBG-mannitol provides excellent bowel distension, thereby avoiding contrast-associated PET artifacts. If this solution is not available, VoLumen provides a satisfactory alternative for bowel distension without relevant PET artifacts.

  12. Magnetic resonance cholangiopancreatography (MRCP) using new negative per-oral contrast agent based on superparamagnetic iron oxide nanoparticles for extrahepatic biliary duct visualization in liver cirrhosis.

    Science.gov (United States)

    Polakova, Katerina; Mocikova, Ingrid; Purova, Dana; Tucek, Pavel; Novak, Pavel; Novotna, Katerina; Izak, Niko; Bielik, Radoslav; Zboril, Radek; Miroslav, Herman

    2016-12-01

    Magnetic resonance cholangiopancreatography (MRCP) is often used for imaging of the biliary tree and is required by surgeons before liver transplantation. Advanced liver cirrhosis and ascites in patients however present diagnostic problems for MRCP. The aim of this study was to find out if the use of our negative per-oral contrast agent containing superparamagnetic iron oxide nanoparticles (SPIO) in MRCP is helpful for imaging of hepatobiliary tree in patients with liver cirrhosis. Forty patients with liver cirrhosis were examined on a 1.5 T MR unit using standard MRCP protocol. Twenty patients (group A) underwent MRCP after administration of per-oral SPIO contrast agent 30 min before examination. In group B, twenty patients were examined without per-oral bowel preparation. Ascites was present in eleven patients from group A and in thirteen patients in group B. Four radiologists analyzed MR images for visibility and delineation of the biliary tree. χ 2 tests were used for comparison of the visibility of intrahepatic and extrahepatic biliary ducts in patients with and without ascites. Better extrahepatic biliary duct visualization and visibility of extraluminal pathologies in patients with ascites was proved after administration of SPIO contrast agent. No statistically significant difference between group A and B was found for visualization of extrahepatic biliary ducts in patients without ascites. Delineation of intrahepatic biliary ducts was independent on bowel preparation. Application of our negative per-oral SPIO contrast agent before MRCP improves the visualization of extrahepatic biliary ducts in patients with ascites which is helpful during the liver surgery, mainly in liver transplantation.

  13. Explaining the Effectiveness of the Contrast Culture Method for Managing Interpersonal Interactions across Cultures

    Science.gov (United States)

    Hiratsuka, Hiroyoshi; Suzuki, Hanako; Pusina, Alexis

    2016-01-01

    One of the current challenges in the field of intercultural education comes from the limited availability of training efficacy studies. The present study focused on explaining the effectiveness of the Contrast Culture Method (CCM) as an intercultural education method for managing interpersonal interactions across cultures between graduate…

  14. Detection of oral HPV infection - Comparison of two different specimen collection methods and two HPV detection methods.

    Science.gov (United States)

    de Souza, Marjorie M A; Hartel, Gunter; Whiteman, David C; Antonsson, Annika

    2018-04-01

    Very little is known about the natural history of oral HPV infection. Several different methods exist to collect oral specimens and detect HPV, but their respective performance characteristics are unknown. We compared two different methods for oral specimen collection (oral saline rinse and commercial saliva kit) from 96 individuals and then analyzed the samples for HPV by two different PCR detection methods (single GP5+/6+ PCR and nested MY09/11 and GP5+/6+ PCR). For the oral rinse samples, the oral HPV prevalence was 10.4% (GP+ PCR; 10% repeatability) vs 11.5% (nested PCR method; 100% repeatability). For the commercial saliva kit samples, the prevalences were 3.1% vs 16.7% with the GP+ PCR vs the nested PCR method (repeatability 100% for both detection methods). Overall the agreement was fair or poor between samples and methods (kappa 0.06-0.36). Standardizing methods of oral sample collection and HPV detection would ensure comparability between future oral HPV studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. A method of pre-surgical oral orthopaedics.

    Science.gov (United States)

    DiBiase, D D; Hunter, S B

    1983-01-01

    A preliminary report of a technique of pre-surgical treatment in cleft lip and palate patients is outlined utilizing an adjustable intra-oral appliance with extra-oral strapping. The appliance is constructed with an adjustable spring for expansion and two shelves overlapping in the midline to allow palatal continuity during treatment. Frequently, only one appliance for each patient is required. The techniques of appliance construction, pre-surgical management and surgical repair of the lip are outlined.

  16. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Zhang, Kai [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhu, Peiping; Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China and Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

  17. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili; Zhang, Kai; Zhu, Peiping; Wu, Ziyu

    2015-01-01

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations

  18. Segmentation methods for breast vasculature in dual-energy contrast-enhanced digital breast tomosynthesis

    Science.gov (United States)

    Lau, Kristen C.; Lee, Hyo Min; Singh, Tanushriya; Maidment, Andrew D. A.

    2015-03-01

    Dual-energy contrast-enhanced digital breast tomosynthesis (DE CE-DBT) uses an iodinated contrast agent to image the three-dimensional breast vasculature. The University of Pennsylvania has an ongoing DE CE-DBT clinical study in patients with known breast cancers. The breast is compressed continuously and imaged at four time points (1 pre-contrast; 3 post-contrast). DE images are obtained by a weighted logarithmic subtraction of the high-energy (HE) and low-energy (LE) image pairs. Temporal subtraction of the post-contrast DE images from the pre-contrast DE image is performed to analyze iodine uptake. Our previous work investigated image registration methods to correct for patient motion, enhancing the evaluation of vascular kinetics. In this project we investigate a segmentation algorithm which identifies blood vessels in the breast from our temporal DE subtraction images. Anisotropic diffusion filtering, Gabor filtering, and morphological filtering are used for the enhancement of vessel features. Vessel labeling methods are then used to distinguish vessel and background features successfully. Statistical and clinical evaluations of segmentation accuracy in DE-CBT images are ongoing.

  19. [Influence of Sex and Age on Contrast Sensitivity Subject to the Applied Method].

    Science.gov (United States)

    Darius, Sabine; Bergmann, Lisa; Blaschke, Saskia; Böckelmann, Irina

    2018-02-01

    The aim of the study was to detect gender and age differences in both photopic and mesopic contrast sensitivity with different methods in relation to German driver's license regulations (Fahrerlaubnisverordnung; FeV). We examined 134 healthy volunteers (53 men, 81 women) with an age between 18 and 76 years, that had been divided into two groups (AG I Mars charts under standardized illumination were applied for photopic contrast sensitivity. We could not find any gender differences. When evaluating age, there were no differences between the two groups for the Mars charts nor in the Rodatest. In all other tests, the younger volunteers achieved significantly better results. For contrast vision, there exists age-adapted cut-off-values. Concerning the driving safety of traffic participants, sufficient photopic and mesopic contrast vision should be focused on, independent of age. Therefore, there is a need to reconsider the age-adapted cut-off-values. Georg Thieme Verlag KG Stuttgart · New York.

  20. Application of subinterval area median contrast filtering method in the recognizing of geochemical anomalies

    International Nuclear Information System (INIS)

    Zhao Ningbo; Fu Jin; Zhang Chuan; Liu Huan

    2012-01-01

    Traditional geochemical processing method sometimes maybe loses some weak anomalies related to mineralization, the authors can avoid the influence of geology background and can solve the problem of recognizing weak anomalies in the low-background and high-background area with the subinterval area median contrast filtering method. In an area of Jiangxi Province, several new anomalies are identified by this method and uranium mineralized prospects are found among them. (authors)

  1. An iterative method for near-field Fresnel region polychromatic phase contrast imaging

    Science.gov (United States)

    Carroll, Aidan J.; van Riessen, Grant A.; Balaur, Eugeniu; Dolbnya, Igor P.; Tran, Giang N.; Peele, Andrew G.

    2017-07-01

    We present an iterative method for polychromatic phase contrast imaging that is suitable for broadband illumination and which allows for the quantitative determination of the thickness of an object given the refractive index of the sample material. Experimental and simulation results suggest the iterative method provides comparable image quality and quantitative object thickness determination when compared to the analytical polychromatic transport of intensity and contrast transfer function methods. The ability of the iterative method to work over a wider range of experimental conditions means the iterative method is a suitable candidate for use with polychromatic illumination and may deliver more utility for laboratory-based x-ray sources, which typically have a broad spectrum.

  2. Study of reduction methods for irradiation on oral mucositis. The examination of reduction methods for mucosal failure

    International Nuclear Information System (INIS)

    Tonogi, Morio; Yamane, Genyuki; Aoyagi, Yutaka; Hasegawa, Azusa; Mizoe, Junetsu; Tsujii, Hirohiko

    2004-01-01

    Reduction methods for irradiation on oral mucosa examined concerning in acute phase of the carbon ion radiotherapy for head and neck malignancies. We enforced a mechanical teeth and gingival cleaning as an Oral hearth care and gargled a polaprezinc with sodium alginate, and azulene- lidocaine with glycerin sodium as a oral linces before radiation. The response of the mucosal failure was reduced compare with no care group. In this Result, we considered that oral hearth care for prevention of infection, and mucosa protection by the drug was important factor. (author)

  3. A speeded-up saliency region-based contrast detection method for small targets

    Science.gov (United States)

    Li, Zhengjie; Zhang, Haiying; Bai, Jiaojiao; Zhou, Zhongjun; Zheng, Huihuang

    2018-04-01

    To cope with the rapid development of the real applications for infrared small targets, the researchers have tried their best to pursue more robust detection methods. At present, the contrast measure-based method has become a promising research branch. Following the framework, in this paper, a speeded-up contrast measure scheme is proposed based on the saliency detection and density clustering. First, the saliency region is segmented by saliency detection method, and then, the Multi-scale contrast calculation is carried out on it instead of traversing the whole image. Second, the target with a certain "integrity" property in spatial is exploited to distinguish the target from the isolated noises by density clustering. Finally, the targets are detected by a self-adaptation threshold. Compared with time-consuming MPCM (Multiscale Patch Contrast Map), the time cost of the speeded-up version is within a few seconds. Additional, due to the use of "clustering segmentation", the false alarm caused by heavy noises can be restrained to a lower level. The experiments show that our method has a satisfied FASR (False alarm suppression ratio) and real-time performance compared with the state-of-art algorithms no matter in cloudy sky or sea-sky background.

  4. A method to evaluate the dose increase in CT with iodinated contrast medium

    International Nuclear Information System (INIS)

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio

    2010-01-01

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical protocols

  5. A method to evaluate the dose increase in CT with iodinated contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio [Department of Radiological Sciences, University of Messina, Messina 98125 (Italy); Department of Physics, University of Messina, Messina 98166 (Italy); University Hospital ' ' G. Martino' ' , Messina 98125 (Italy); Department of Radiological Sciences, University of Messina, Messina 98125 (Italy) and University Hospital ' ' G. Martino' ' , Messina 98125 (Italy)

    2010-08-15

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical

  6. A review on brightness preserving contrast enhancement methods for digital image

    Science.gov (United States)

    Rahman, Md Arifur; Liu, Shilong; Li, Ruowei; Wu, Hongkun; Liu, San Chi; Jahan, Mahmuda Rawnak; Kwok, Ngaiming

    2018-04-01

    Image enhancement is an imperative step for many vision based applications. For image contrast enhancement, popular methods adopt the principle of spreading the captured intensities throughout the allowed dynamic range according to predefined distributions. However, these algorithms take little or no consideration into account of maintaining the mean brightness of the original scene, which is of paramount importance to carry the true scene illumination characteristics to the viewer. Though there have been significant amount of reviews on contrast enhancement methods published, updated review on overall brightness preserving image enhancement methods is still scarce. In this paper, a detailed survey is performed on those particular methods that specifically aims to maintain the overall scene illumination characteristics while enhancing the digital image.

  7. Oral contrast for CT in patients with acute non-traumatic abdominal and pelvic pain: what should be its current role?

    Science.gov (United States)

    Kielar, Ania Z; Patlas, Michael N; Katz, Douglas S

    2016-10-01

    Positive oral contrast agents, including barium suspensions and water-soluble iodinated solutions, have traditionally been used in conjunction with the CT evaluation of patients with abdominal and pelvic pain. Due to continued advancements in CT technology, and due to increasing obesity and correspondingly a general increase in the intra-abdominal and intra-pelvic fat separating bowel loops in North American patients and in patients in other parts of the world over the past few decades, the ability of radiologists to accurately evaluate the cause of acute symptoms has substantially improved. Recent research and evolving imaging society guidelines/systematic reviews increasingly support performing CT scans of the abdomen and pelvis without the need for positive oral contrast in these types of adult patient populations, in most clinical situations. Increased patient throughput, patient preference, patient safety, and most importantly, retention of high diagnostic accuracy, are reasons for this recent change in practice to routinely omit the use of enteric contrast agents for the majority of patients presenting with acute abdominal and pelvic pain whom are undergoing emergency CT.

  8. Prediction and monitoring of the response to chemoradiotherapy in oral squamous cell carcinomas using a pharmacokinetic analysis based on the dynamic contrast-enhanced MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Chikui, Toru; Kawazu, Toshiyuki; Yoshiura, Kazunori [Kyushu University, Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Fukuoka (Japan); Kawano, Shintaro [Kyushu University, Section of Oral and Maxillofacial Oncology, Division of Maxillofacial Diagnostic and Surgical Sciences, Faculty of Dental Science, Fukuoka (Japan); Hatakenaka, Masamitsu [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Kyushu University, Radiology Center, Kyushu University Hospital, Fukuoka (Japan); Koga, Syouzou; Ohga, Masahiro [Kyushu University, Radiology Center, Kyushu University Hospital, Fukuoka (Japan); Matsuo, Yoshio; Sunami, Syunya [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Sugiura, Tsuyoshi [Kyushu University, Department of Maxillofacial Surgery, Kyushu University Hospital, Fukuoka (Japan); Shioyama, Yoshiyuki [Kyushu University, Department of Heavy Particle Therapy and Radiation Oncology, Graduate School of Medical Sciences, Fukuoka (Japan); Obara, Makoto [Philips Electronics Japan, Ltd 2-13-37, Konan Minato-ku, Tokyo (Japan)

    2011-08-15

    To evaluate whether a pharmacokinetic analysis is useful for both predicting and monitoring the response to chemoradiotherapy (CRT) in oral cancer. Patients with oral squamous cell carcinoma treated with preoperative CRT and surgery were enrolled. They underwent dynamic contrast-enhanced MRI before (n = 23), and after CRT (n = 20). We estimated four parameters: arrival time of contrast medium (TA), exchange rate constant from the extracellular extravascular space (EES) to plasma (k{sub ep}), elimination of contrast medium from the central compartment (k{sub el}) and an amplitude scaling constant (AH) using the Brix model. The histological evaluation of the effects of CRT was performed according to Ohboshi and Shimosato's classification. We analysed the correlation between the parameters and the histological evaluation. The pre-CRT AH between the responders and non-responders was significantly different (P = 0.046), however, the three parameters (TA, K{sub ep}, K{sub el}) were not significantly different among the groups (P = 0.76, P = 0.60, P = 0.09). As AH decreased, the tumour response improved. The change in the AH between the pre- and post-CRT of responders was significantly higher than that of non-responders (P = 0.043). The AH, which is affected by the ratio of the EES, was an important parameter for predicting and monitoring the tumour response to CRT. (orig.)

  9. A contrast enhancement method for improving the segmentation of breast lesions on ultrasonography.

    Science.gov (United States)

    Flores, Wilfrido Gómez; Pereira, Wagner Coelho de Albuquerque

    2017-01-01

    This paper presents an adaptive contrast enhancement method based on sigmoidal mapping function (SACE) used for improving the computerized segmentation of breast lesions on ultrasound. First, from the original ultrasound image an intensity variation map is obtained, which is used to generate local sigmoidal mapping functions related to distinct contextual regions. Then, a bilinear interpolation scheme is used to transform every original pixel to a new gray level value. Also, four contrast enhancement techniques widely used in breast ultrasound enhancement are implemented: histogram equalization (HEQ), contrast limited adaptive histogram equalization (CLAHE), fuzzy enhancement (FEN), and sigmoid based enhancement (SEN). In addition, these contrast enhancement techniques are considered in a computerized lesion segmentation scheme based on watershed transformation. The performance comparison among techniques is assessed in terms of both the quality of contrast enhancement and the segmentation accuracy. The former is quantified by the measure, where the greater the value, the better the contrast enhancement, whereas the latter is calculated by the Jaccard index, which should tend towards unity to indicate adequate segmentation. The experiments consider a data set with 500 breast ultrasound images. The results show that SACE outperforms its counterparts, where the median values for the measure are: SACE: 139.4, SEN: 68.2, HEQ: 64.1, CLAHE: 62.8, and FEN: 7.9. Considering the segmentation performance results, the SACE method presents the largest accuracy, where the median values for the Jaccard index are: SACE: 0.81, FEN: 0.80, CLAHE: 0.79, HEQ: 77, and SEN: 0.63. The SACE method performs well due to the combination of three elements: (1) the intensity variation map reduces intensity variations that could distort the real response of the mapping function, (2) the sigmoidal mapping function enhances the gray level range where the transition between lesion and background

  10. Use and misuse of mixed methods in population oral health research: A scoping review.

    Science.gov (United States)

    Gupta, A; Keuskamp, D

    2018-05-30

    Despite the known benefits of a mixed methods approach in health research, little is known of its use in the field of population oral health. To map the extent of literature using a mixed methods approach to examine population oral health outcomes. For a comprehensive search of all the available literature published in the English language, databases including PubMed, Dentistry and Oral Sciences Source (DOSS), CINAHL, Web of Science and EMBASE (including Medline) were searched using a range of keywords from inception to October 2017. Only peer-reviewed, population-based studies of oral health outcomes conducted among non-institutionalised participants and using mixed methods were considered eligible for inclusion. Only nine studies met the inclusion criteria and were included in the review. The most frequent oral health outcome investigated was caries experience. However, most studies lacked a theoretical rationale or framework for using mixed methods, or supporting the use of qualitative data. Concurrent triangulation with a convergent design was the most commonly used mixed methods typology for integrating quantitative and qualitative data. The tools used to collect quantitative and qualitative data were mostly limited to surveys and interviews. With growing complexity recognised in the determinants of oral disease, future studies addressing population oral health outcomes are likely to benefit from the use of mixed methods. Explicit consideration of theoretical framework and methodology will strengthen those investigations. Copyright© 2018 Dennis Barber Ltd.

  11. Evaluation of bowel distension and bowel wall visualization according to patient positions during administration of oral contrast media for CT enterography.

    Science.gov (United States)

    Lee, Seul Bi; Kim, Seung Ho; Son, Jung Hee; Baik, Ji Yeon

    2017-12-01

    To compare small bowel distension and bowel wall visualization among three different patients' positions (supine, sitting and right decubitus) during administration of oral contrast media in preparation for CT enterography (CTE). A total of 150 consecutive patients (104 males and 46 females; mean age 34.6 years, range 15-78 years) who were scheduled to undergo CTE were recruited. Patients were randomly allocated into the three position groups during oral contrast media administration, and there were 50 patients in each group. Two blinded radiologists independently scored the luminal distension and visualization of the bowel wall using a continuous 5-point scale (1: worst and 5: best) at the jejunum and ileum. The Mann-Whitney U test was used to evaluate differences between any two groups among the three positions for bowel distension and wall visualization. For ileal distension, the supine and sitting positions performed better than the right decubitus position [for reader 1, mean: 3.4/3.2/2.9 (hereafter, supine/sitting/right decubitus in order), p = 0.002/0.033; for reader 2, 3.3/3.0/2.6, p 0.05, respectively). For bowel wall visualization, the supine and sitting positions were superior to the right decubitus position for the ileum when scored by one reader (4.0/3.8/3.4, p = 0.001/0.015). Supine and sitting positions during the administration of oral contrast media provided better ileal distension than the right decubitus position in obtaining CTE. Advances in knowledge: The performance of CTE largely depends on adequate luminal distension and wall visualization. As the terminal ileum is the predominant site of small bowel pathology for inflammatory bowel disease, the supine or sitting position would be preferable for patients who are suspected of having small bowel pathology.

  12. Robustness of phase retrieval methods in x-ray phase contrast imaging: A comparison

    International Nuclear Information System (INIS)

    Yan, Aimin; Wu, Xizeng; Liu, Hong

    2011-01-01

    Purpose: The robustness of the phase retrieval methods is of critical importance for limiting and reducing radiation doses involved in x-ray phase contrast imaging. This work is to compare the robustness of two phase retrieval methods by analyzing the phase maps retrieved from the experimental images of a phantom. Methods: Two phase retrieval methods were compared. One method is based on the transport of intensity equation (TIE) for phase contrast projections, and the TIE-based method is the most commonly used method for phase retrieval in the literature. The other is the recently developed attenuation-partition based (AP-based) phase retrieval method. The authors applied these two methods to experimental projection images of an air-bubble wrap phantom for retrieving the phase map of the bubble wrap. The retrieved phase maps obtained by using the two methods are compared. Results: In the wrap's phase map retrieved by using the TIE-based method, no bubble is recognizable, hence, this method failed completely for phase retrieval from these bubble wrap images. Even with the help of the Tikhonov regularization, the bubbles are still hardly visible and buried in the cluttered background in the retrieved phase map. The retrieved phase values with this method are grossly erroneous. In contrast, in the wrap's phase map retrieved by using the AP-based method, the bubbles are clearly recovered. The retrieved phase values with the AP-based method are reasonably close to the estimate based on the thickness-based measurement. The authors traced these stark performance differences of the two methods to their different techniques employed to deal with the singularity problem involved in the phase retrievals. Conclusions: This comparison shows that the conventional TIE-based phase retrieval method, regardless if Tikhonov regularization is used or not, is unstable against the noise in the wrap's projection images, while the AP-based phase retrieval method is shown in these

  13. Restoration of the contrast of cerebral blood flows by the spatial deconvolution method

    International Nuclear Information System (INIS)

    Compingt, D.L.; Philippon, B.L.

    1982-01-01

    The measurement of regional cerebral blood flows (rCBF) with a gamma camera during xenon-133 inhalation necessitates collimators with high efficiency. Their spatial resolutions are weak: on the images given by a F.W.H.M. collimator (25 mm to 5 cm depth of water), the contrast restoration method by the ponctual dispersion function (P.D.F.) is used. The convolution product (Image)=(Object)*(P.D.F.) is resolved by a bidimensional Fast Fourier Transform treatment. The high frequencies are eliminated by a progressive filtration. The rCBF is calculated with Obrist's method. The Initial Slope Index is only used. A rCBF image with the calculator is also realized. The numerical values are compared with the normal treatment (N) without contrast restoration and after restoration. 22 patients are so treated after severe cerebral strokes. The hemispheric average of the flows according to the 2 treatments is unchanged (difference: 1.1%). The contrast between higher and lower flow areas is increasing by 73% after contrast restoration (significant difference: p [fr

  14. Sparse contrast-source inversion using linear-shrinkage-enhanced inexact Newton method

    KAUST Repository

    Desmal, Abdulla

    2014-07-01

    A contrast-source inversion scheme is proposed for microwave imaging of domains with sparse content. The scheme uses inexact Newton and linear shrinkage methods to account for the nonlinearity and ill-posedness of the electromagnetic inverse scattering problem, respectively. Thresholded shrinkage iterations are accelerated using a preconditioning technique. Additionally, during Newton iterations, the weight of the penalty term is reduced consistently with the quadratic convergence of the Newton method to increase accuracy and efficiency. Numerical results demonstrate the applicability of the proposed method.

  15. Sparse contrast-source inversion using linear-shrinkage-enhanced inexact Newton method

    KAUST Repository

    Desmal, Abdulla; Bagci, Hakan

    2014-01-01

    A contrast-source inversion scheme is proposed for microwave imaging of domains with sparse content. The scheme uses inexact Newton and linear shrinkage methods to account for the nonlinearity and ill-posedness of the electromagnetic inverse scattering problem, respectively. Thresholded shrinkage iterations are accelerated using a preconditioning technique. Additionally, during Newton iterations, the weight of the penalty term is reduced consistently with the quadratic convergence of the Newton method to increase accuracy and efficiency. Numerical results demonstrate the applicability of the proposed method.

  16. In vivo X-Ray Computed Tomographic Imaging of Soft Tissue with Native, Intravenous, or Oral Contrast

    Science.gov (United States)

    Wathen, Connor A.; Foje, Nathan; van Avermaete, Tony; Miramontes, Bernadette; Chapaman, Sarah E.; Sasser, Todd A.; Kannan, Raghuraman; Gerstler, Steven; Leevy, W. Matthew

    2013-01-01

    X-ray Computed Tomography (CT) is one of the most commonly utilized anatomical imaging modalities for both research and clinical purposes. CT combines high-resolution, three-dimensional data with relatively fast acquisition to provide a solid platform for non-invasive human or specimen imaging. The primary limitation of CT is its inability to distinguish many soft tissues based on native contrast. While bone has high contrast within a CT image due to its material density from calcium phosphate, soft tissue is less dense and many are homogenous in density. This presents a challenge in distinguishing one type of soft tissue from another. A couple exceptions include the lungs as well as fat, both of which have unique densities owing to the presence of air or bulk hydrocarbons, respectively. In order to facilitate X-ray CT imaging of other structures, a range of contrast agents have been developed to selectively identify and visualize the anatomical properties of individual tissues. Most agents incorporate atoms like iodine, gold, or barium because of their ability to absorb X-rays, and thus impart contrast to a given organ system. Here we review the strategies available to visualize lung, fat, brain, kidney, liver, spleen, vasculature, gastrointestinal tract, and liver tissues of living mice using either innate contrast, or commercial injectable or ingestible agents with selective perfusion. Further, we demonstrate how each of these approaches will facilitate the non-invasive, longitudinal, in vivo imaging of pre-clinical disease models at each anatomical site. PMID:23711461

  17. MR enterography with oral contrast agent composed of methylcellulose, low-dose barium sulfate, sorbitol, and lactulose: assessment of diagnostic performance, reliability, image quality, and patient tolerance.

    Science.gov (United States)

    Evrimler, Sehnaz; Algin, Oktay

    2016-01-01

    The objective was to show efficiency of magnetic resonance enterography (MRE) with our previously assessed new oral contrast agent. Each bowel segments was evaluated for luminal distension, wall conspicuity, wall thickening, and hyperintensity on fat-saturated (FS) T2-weighted and contrast enhancement on postcontrast FS T1-weighted images. Also, consensus scoring results of MRE exams were compared with the gold standard tests in terms of active inflammatory bowel disease detection. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of MRE for active inflammatory bowel disease detection were 62%, 98%, 80%, 96%, and 71.4%, respectively. MRE obtained with the new mixture has a high reliability and shows good correlation with endoscopic examination±biopsy. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Small angle neutron scattering in polyelectrolyte solutions: investigation of polymethacrylic acid solutions by contrast variation method

    International Nuclear Information System (INIS)

    Glavata, D.; Pleshtil, I.; Kunchenko, A.B.; Ostanevich, Yu.M.

    1982-01-01

    Neutron experiments performed by the contrast (background) variation method allows to understand better the role that hydration plays in the study of macromolecules and to draw the connection between the excess scattering amplitude of hydrated molecule with its partial volume. The observed dependence of the compensation point on the degree of neutralization apparently plays an important role in the investigation of polyelectrolytes of biological origin

  19. MR-imaging of the breast at 0.5 Tesla: menstrual-cycle dependency of parenchymal contrast enhancement in healthy volunteers with oral contraceptive use?; MR-Mammographie bei 0,5 Tesla: Menstruationszyklusabhaengigkeit der Kontrastmittelanreicherung unter hormoneller Kontrazeption?

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzen, J.; Welger, J.; Krupski, G.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Lisboa, B.W. [Klinik und Poliklinik fuer Frauenheilkunde und Geburtshilfe, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2003-04-01

    Introduction: To evaluate changes of contrast medium enhancement of the breast parenchyma due to menstrual cycle in healthy volunteers with oral contraceptive use in MR-imaging of the breast. Material and Methods: 15 healthy volunteers (age: 22 - 36, mean 28,2) without breast disease were examined two times during one menstrual cycle (days 7 - 14 and days 21 - 2). Two volunteers were examined only in the second part of the cycle (days 21 - 2). All volunteers used oral contraceptives for more than 6 month continuously. Examinations were performed with a 0,5 T magnet (dynamic 3D-gradient echo protocol with subtraction postprocessing). We evaluated the number of enhancing foci and the parenchymal contrast medium enhancement during the different phases of the cycle by region of interest. Results: Only a total of two enhancing foci were found in 2 of 17 volunteers. Time/signal intensity diagrams in these both cases were not suspicious (< 80% initial signal increase after of contrast medium injection, no wash-out phenomenon) and sonography of the breast in these two cases was inconspicuous. Contrast medium enhancement of breast parenchyma in cycle days 7 - 14 (mean enhancement: 0.12 - 0.26, minutes 1 - 9 p.i.) was not significantly different (p = 0.2209; Wilcoxon signed rank test) from cycle days 21 - 2 (mean: 0.13 - 0.32). Conclusion: Menstrual cycle dependency of parenchymal contrast medium enhancement seems to be of minor relevance for premenopausal women with use of oral contraceptives. (orig.) [German] Fragestellung: Untersuchung der Kontrastmittelaufnahme des Brustparenchyms in Abhaengigkeit vom Menstruationszyklus bei gesunden Probandinnen unter oraler Kontrazeption. Material und Methode: Bei 15 gesunden Probandinnen ohne Brusterkrankung in der Anamnese wurde eine MR-Mammographie zweimal waehrend eines Menstruationszyklus durchgefuehrt (Zyklustag: 7 - 14 und 21 - 2). Bei zwei weiteren Probandinnen erfolgte die MR-Mammographie nur in der zweiten Zyklushaelfte

  20. In vivo X-Ray Computed Tomographic Imaging of Soft Tissue with Native, Intravenous, or Oral Contrast

    Directory of Open Access Journals (Sweden)

    W. Matthew Leevy

    2013-05-01

    Full Text Available X-ray Computed Tomography (CT is one of the most commonly utilized anatomical imaging modalities for both research and clinical purposes. CT combines high-resolution, three-dimensional data with relatively fast acquisition to provide a solid platform for non-invasive human or specimen imaging. The primary limitation of CT is its inability to distinguish many soft tissues based on native contrast. While bone has high contrast within a CT image due to its material density from calcium phosphate, soft tissue is less dense and many are homogenous in density. This presents a challenge in distinguishing one type of soft tissue from another. A couple exceptions include the lungs as well as fat, both of which have unique densities owing to the presence of air or bulk hydrocarbons, respectively. In order to facilitate X-ray CT imaging of other structures, a range of contrast agents have been developed to selectively identify and visualize the anatomical properties of individual tissues. Most agents incorporate atoms like iodine, gold, or barium because of their ability to absorb X-rays, and thus impart contrast to a given organ system. Here we review the strategies available to visualize lung, fat, brain, kidney, liver, spleen, vasculature, gastrointestinal tract, and liver tissues of living mice using either innate contrast, or commercial injectable or ingestible agents with selective perfusion. Further, we demonstrate how each of these approaches will facilitate the non-invasive, longitudinal, in vivo imaging of pre-clinical disease models at each anatomical site.

  1. [Accuracy of three methods for the rapid diagnosis of oral candidiasis].

    Science.gov (United States)

    Lyu, X; Zhao, C; Yan, Z M; Hua, H

    2016-10-09

    Objective: To explore a simple, rapid and efficient method for the diagnosis of oral candidiasis in clinical practice. Methods: Totally 124 consecutive patients with suspected oral candidiasis were enrolled from Department of Oral Medicine, Peking University School and Hospital of Stomatology, Beijing, China. Exfoliated cells of oral mucosa and saliva or concentrated oral rinse) obtained from all participants were tested by three rapid smear methods(10% KOH smear, gram-stained smear, Congo red stained smear). The diagnostic efficacy(sensitivity, specificity, Youden's index, likelihood ratio, consistency, predictive value and area under curve(AUC) of each of the above mentioned three methods was assessed by comparing the results with the gold standard(combination of clinical diagnosis, laboratory diagnosis and expert opinion). Results: Gram-stained smear of saliva(or concentrated oral rinse) demonstrated highest sensitivity(82.3%). Test of 10%KOH smear of exfoliated cells showed highest specificity(93.5%). Congo red stained smear of saliva(or concentrated oral rinse) displayed highest diagnostic efficacy(79.0% sensitivity, 80.6% specificity, 0.60 Youden's index, 4.08 positive likelihood ratio, 0.26 negative likelihood ratio, 80% consistency, 80.3% positive predictive value, 79.4% negative predictive value and 0.80 AUC). Conclusions: Test of Congo red stained smear of saliva(or concentrated oral rinse) could be used as a point-of-care tool for the rapid diagnosis of oral candidiasis in clinical practice. Trial registration: Chinese Clinical Trial Registry, ChiCTR-DDD-16008118.

  2. Mode decomposition methods for flows in high-contrast porous media. Global-local approach

    KAUST Repository

    Ghommem, Mehdi; Presho, Michael; Calo, Victor M.; Efendiev, Yalchin R.

    2013-01-01

    In this paper, we combine concepts of the generalized multiscale finite element method (GMsFEM) and mode decomposition methods to construct a robust global-local approach for model reduction of flows in high-contrast porous media. This is achieved by implementing Proper Orthogonal Decomposition (POD) and Dynamic Mode Decomposition (DMD) techniques on a coarse grid computed using GMsFEM. The resulting reduced-order approach enables a significant reduction in the flow problem size while accurately capturing the behavior of fully-resolved solutions. We consider a variety of high-contrast coefficients and present the corresponding numerical results to illustrate the effectiveness of the proposed technique. This paper is a continuation of our work presented in Ghommem et al. (2013) [1] where we examine the applicability of POD and DMD to derive simplified and reliable representations of flows in high-contrast porous media on fully resolved models. In the current paper, we discuss how these global model reduction approaches can be combined with local techniques to speed-up the simulations. The speed-up is due to inexpensive, while sufficiently accurate, computations of global snapshots. © 2013 Elsevier Inc.

  3. A reconstruction method for cone-beam differential x-ray phase-contrast computed tomography.

    Science.gov (United States)

    Fu, Jian; Velroyen, Astrid; Tan, Renbo; Zhang, Junwei; Chen, Liyuan; Tapfer, Arne; Bech, Martin; Pfeiffer, Franz

    2012-09-10

    Most existing differential phase-contrast computed tomography (DPC-CT) approaches are based on three kinds of scanning geometries, described by parallel-beam, fan-beam and cone-beam. Due to the potential of compact imaging systems with magnified spatial resolution, cone-beam DPC-CT has attracted significant interest. In this paper, we report a reconstruction method based on a back-projection filtration (BPF) algorithm for cone-beam DPC-CT. Due to the differential nature of phase contrast projections, the algorithm restrains from differentiation of the projection data prior to back-projection, unlike BPF algorithms commonly used for absorption-based CT data. This work comprises a numerical study of the algorithm and its experimental verification using a dataset measured with a three-grating interferometer and a micro-focus x-ray tube source. Moreover, the numerical simulation and experimental results demonstrate that the proposed method can deal with several classes of truncated cone-beam datasets. We believe that this feature is of particular interest for future medical cone-beam phase-contrast CT imaging applications.

  4. Mode decomposition methods for flows in high-contrast porous media. Global-local approach

    KAUST Repository

    Ghommem, Mehdi

    2013-11-01

    In this paper, we combine concepts of the generalized multiscale finite element method (GMsFEM) and mode decomposition methods to construct a robust global-local approach for model reduction of flows in high-contrast porous media. This is achieved by implementing Proper Orthogonal Decomposition (POD) and Dynamic Mode Decomposition (DMD) techniques on a coarse grid computed using GMsFEM. The resulting reduced-order approach enables a significant reduction in the flow problem size while accurately capturing the behavior of fully-resolved solutions. We consider a variety of high-contrast coefficients and present the corresponding numerical results to illustrate the effectiveness of the proposed technique. This paper is a continuation of our work presented in Ghommem et al. (2013) [1] where we examine the applicability of POD and DMD to derive simplified and reliable representations of flows in high-contrast porous media on fully resolved models. In the current paper, we discuss how these global model reduction approaches can be combined with local techniques to speed-up the simulations. The speed-up is due to inexpensive, while sufficiently accurate, computations of global snapshots. © 2013 Elsevier Inc.

  5. The comparison of two methods to obtain human oral keratinocytes in primary culture

    International Nuclear Information System (INIS)

    Klingbeil, Maria Fatima Guarizo

    2006-01-01

    The therapeutic procedures frequently used in oral treatments for the pathological diseases are surgical, resulting in failures of the mucosal continuity.The possibility to obtain transplantable oral epithelia from an in vitro cell culture opens new utilization perspectives not only to where it comes from, but also as a reconstructive material for other parts of the human body, such as: urethra, epithelia corneo-limbal, cornea, ocular surface. Many researchers still use controversial methods for obtaining cells. It was therefore evaluated and compared the efficiency in both methods: enzymatic and direct explant to obtain oral keratinocytes from human oral mucosa. Fragments of intra oral epithelial tissues from healthy human subjects, undergoing dental surgeries, were donated to the research project. The keratinocytes were cultivated over a feeder-layer from a previously irradiated 3T3 Swiss albino fibroblasts. In this study it was compared the time needed in the cell obtention, the best cell amount between both methods, the life-span, the cell capacity to form an in vitro epithelia and its morphologic structure. The results in the assessment of both methods have shown the possibility to obtain keratinocytes from a small oral fragment, but at the same time we may verify the advantages and peculiar restrictions for each one of both analyzed methods. (author)

  6. MR of the small bowel with a biphasic oral contrast agent (polyethylene glycol): technical aspects and findings in patients affected by Crohn's disease.

    Science.gov (United States)

    Laghi, Andrea; Paolantonio, Pasquale; Iafrate, Franco; Borrelli, Osvaldo; Dito, Lucia; Tomei, Ernesto; Cucchiara, Salvatore; Passariello, Roberto

    2003-01-01

    To report our experience using MR of the small bowel with polyethylene glycol (PEG) solution as an oral contrast agent in a population of adults and children with known Crohn's disease. 40 patients (29 males; 11 females), 15 adults (age range 24-52 years) and 25 children (age range 5-17 years), with known Crohn's disease, underwent MR of the small bowel using a supeconductive 1.5 T magnet, and polyethylene glycol solution as an oral contrast agent. The fixed amount of contrast agent was 750-1000 ml for adults and 10 ml/kg of body weight for children. The Crohn's Disease Activity Index (CDAI) was available in all patients. Our study protocol included the acquisition of T2-weighted half-Fourier single-shot turbo spin-echo (HASTE) sequences and true fast imaging in the steady-state precession (true-FISP) sequences, followed by the acquisition of "spoiled" 2D gradient echo T1-weighted sequences with fat suppression (FLASH, fast low-angle shot) or alternatively "spoiled" 3D (VIBE, volume interpolated breath-hold examination), acquired 70 seconds after intravenous administration of gadopentetate dimeglumine (Gd-DTPA) (0,1 mmol/kg). A specific MR score was created and calculated for each patient and was compared by means of the Spearman rank with CDAI. In all patients no significant side effects were observed and the MR examination was well tolerated even by paediatric patients. In all cases MR showed a small bowel wall thickening (> 4 mm) in the terminal ileum, with lumen stenosis in 26 patients. In 3 cases pathological segments proximal to the terminal ileum were observed and in another 3 cases caecal involvement was visible. The MR examination was able to show abnormalities of perivisceral fat tissue in 15 patients, mesenteric lymphadenopathy in 1 patient and abdominal abscess in 1 case. The Spearman rank showed a statistically significant correlation between CDAI and the MR score (r = 0.91, P = 0,0001). MR using PEG as an oral contrast agent could be considered a test

  7. Acute Adverse Reactions to Nonionic Iodinated Contrast Media for CT: Prospective Randomized Evaluation of the Effects of Dehydration, Oral Rehydration, and Patient Risk Factors.

    Science.gov (United States)

    Motosugi, Utaroh; Ichikawa, Tomoaki; Sano, Katsuhiro; Onishi, Hiroshi

    2016-11-01

    The objective of our study was to determine the effects of dehydration and oral rehydration on the incidence of acute adverse reactions to iodinated contrast media administered during abdominal and pelvic CT in outpatients. For our prospective randomized study performed at a single institution, adult outpatients undergoing contrast-enhanced abdominal CT were randomly divided into a rehydration group (n = 2244 patients [1379 men and 865 women]; mean age, 65.2 years; age range, 18-90 years) and a control group (n = 3715 [2112 male patients and 1603 female patients]; mean age, 65.8 years; age range, 17-96 years), which included an age- and sex-matched subgroup (adjusted control group, n = 2244). The rehydration group received an oral rehydration solution (500 mL of liquid in which osmotic pressure is adjusted to enhance gastrointestinal absorption) before abdominal and pelvic CT. Patients were also divided into subclinically dehydrated (n = 997) and hydrated (n = 4962) groups according to their answers to a questionnaire that they completed before the CT examination. The patients were interviewed about contrast-induced adverse reactions before they left the CT room, and the reactions were categorized as allergiclike or physiologic. The incidence of reactions was compared between the rehydration and control groups and between the subclinical dehydration and hydrated groups. The rehydration and control groups were compared with an unpaired t test or a chi-square or Fisher test. The overall incidence of an acute adverse reaction was 4.3% (254/5959); the acute adverse reactions included 136 allergiclike and 118 physiologic reactions. Fourteen allergiclike and nine physiologic reactions were moderate grade, and none was severe. There was no significant difference between the rehydration group and adjusted control group in the overall incidence of adverse reactions (99/2244 [4.4%] vs 100/2244 [4.5%], respectively; p = 0.9422) or between the subclinically dehydrated group

  8. Automatic neuron segmentation and neural network analysis method for phase contrast microscopy images.

    Science.gov (United States)

    Pang, Jincheng; Özkucur, Nurdan; Ren, Michael; Kaplan, David L; Levin, Michael; Miller, Eric L

    2015-11-01

    Phase Contrast Microscopy (PCM) is an important tool for the long term study of living cells. Unlike fluorescence methods which suffer from photobleaching of fluorophore or dye molecules, PCM image contrast is generated by the natural variations in optical index of refraction. Unfortunately, the same physical principles which allow for these studies give rise to complex artifacts in the raw PCM imagery. Of particular interest in this paper are neuron images where these image imperfections manifest in very different ways for the two structures of specific interest: cell bodies (somas) and dendrites. To address these challenges, we introduce a novel parametric image model using the level set framework and an associated variational approach which simultaneously restores and segments this class of images. Using this technique as the basis for an automated image analysis pipeline, results for both the synthetic and real images validate and demonstrate the advantages of our approach.

  9. Mode decomposition methods for flows in high-contrast porous media. A global approach

    KAUST Repository

    Ghommem, Mehdi; Calo, Victor M.; Efendiev, Yalchin R.

    2014-01-01

    We apply dynamic mode decomposition (DMD) and proper orthogonal decomposition (POD) methods to flows in highly-heterogeneous porous media to extract the dominant coherent structures and derive reduced-order models via Galerkin projection. Permeability fields with high contrast are considered to investigate the capability of these techniques to capture the main flow features and forecast the flow evolution within a certain accuracy. A DMD-based approach shows a better predictive capability due to its ability to accurately extract the information relevant to long-time dynamics, in particular, the slowly-decaying eigenmodes corresponding to largest eigenvalues. Our study enables a better understanding of the strengths and weaknesses of the applicability of these techniques for flows in high-contrast porous media. Furthermore, we discuss the robustness of DMD- and POD-based reduced-order models with respect to variations in initial conditions, permeability fields, and forcing terms. © 2013 Elsevier Inc.

  10. Value and depreciation of mineral resources over the very long run: An empirical contrast of different methods

    OpenAIRE

    Rubio Varas, M. del Mar

    2005-01-01

    The paper contrasts empirically the results of alternative methods for estimating the value and the depreciation of mineral resources. The historical data of Mexico and Venezuela, covering the period 1920s-1980s, is used to contrast the results of several methods. These are the present value, the net price method, the user cost method and the imputed income method. The paper establishes that the net price and the user cost are not competing methods as such, but alternative adjustments to diff...

  11. An eigenfunction method for reconstruction of large-scale and high-contrast objects.

    Science.gov (United States)

    Waag, Robert C; Lin, Feng; Varslot, Trond K; Astheimer, Jeffrey P

    2007-07-01

    A multiple-frequency inverse scattering method that uses eigenfunctions of a scattering operator is extended to image large-scale and high-contrast objects. The extension uses an estimate of the scattering object to form the difference between the scattering by the object and the scattering by the estimate of the object. The scattering potential defined by this difference is expanded in a basis of products of acoustic fields. These fields are defined by eigenfunctions of the scattering operator associated with the estimate. In the case of scattering objects for which the estimate is radial, symmetries in the expressions used to reconstruct the scattering potential greatly reduce the amount of computation. The range of parameters over which the reconstruction method works well is illustrated using calculated scattering by different objects. The method is applied to experimental data from a 48-mm diameter scattering object with tissue-like properties. The image reconstructed from measurements has, relative to a conventional B-scan formed using a low f-number at the same center frequency, significantly higher resolution and less speckle, implying that small, high-contrast structures can be demonstrated clearly using the extended method.

  12. Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity.

    Science.gov (United States)

    Koefoed, Vilhelm F; Baste, Valborg; Roumes, Corinne; Høvding, Gunnar

    2015-03-01

    This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods. A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03). The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.

  13. Recent mouse and rat methods for the study of experimental oral candidiasis.

    Science.gov (United States)

    Costa, Anna C B P; Pereira, Cristiane A; Junqueira, Juliana C; Jorge, Antonio O C

    2013-07-01

    The Candida genus expresses virulence factors that, when combined with immunosuppression and other risk factors, can cause different manifestations of oral candidiasis. The treatment of mucosal infections caused by Candida and the elucidation of the disease process have proven challenging. Therefore, the study of experimentally induced oral candidiasis in rats and mice is useful to clarify the etiopathology of this condition, improve diagnosis, and search for new therapeutic options because the disease process in these animals is similar to that of human candidiasis lesions. Here, we describe and discuss new studies involving rat and mouse models of oral candidiasis with respect to methods for inducing experimental infection, methods for evaluating the development of experimental candidiasis, and new treatment strategies for oral candidiasis.

  14. Recent mouse and rat methods for the study of experimental oral candidiasis

    Science.gov (United States)

    Costa, Anna CBP; Pereira, Cristiane A; Junqueira, Juliana C; Jorge, Antonio OC

    2013-01-01

    The Candida genus expresses virulence factors that, when combined with immunosuppression and other risk factors, can cause different manifestations of oral candidiasis. The treatment of mucosal infections caused by Candida and the elucidation of the disease process have proven challenging. Therefore, the study of experimentally induced oral candidiasis in rats and mice is useful to clarify the etiopathology of this condition, improve diagnosis, and search for new therapeutic options because the disease process in these animals is similar to that of human candidiasis lesions. Here, we describe and discuss new studies involving rat and mouse models of oral candidiasis with respect to methods for inducing experimental infection, methods for evaluating the development of experimental candidiasis, and new treatment strategies for oral candidiasis. PMID:23715031

  15. Elastic frequency-domain finite-difference contrast source inversion method

    International Nuclear Information System (INIS)

    He, Qinglong; Chen, Yong; Han, Bo; Li, Yang

    2016-01-01

    In this work, we extend the finite-difference contrast source inversion (FD-CSI) method to the frequency-domain elastic wave equations, where the parameters describing the subsurface structure are simultaneously reconstructed. The FD-CSI method is an iterative nonlinear inversion method, which exhibits several strengths. First, the finite-difference operator only relies on the background media and the given angular frequency, both of which are unchanged during inversion. Therefore, the matrix decomposition is performed only once at the beginning of the iteration if a direct solver is employed. This makes the inversion process relatively efficient in terms of the computational cost. In addition, the FD-CSI method automatically normalizes different parameters, which could avoid the numerical problems arising from the difference of the parameter magnitude. We exploit a parallel implementation of the FD-CSI method based on the domain decomposition method, ensuring a satisfactory scalability for large-scale problems. A simple numerical example with a homogeneous background medium is used to investigate the convergence of the elastic FD-CSI method. Moreover, the Marmousi II model proposed as a benchmark for testing seismic imaging methods is presented to demonstrate the performance of the elastic FD-CSI method in an inhomogeneous background medium. (paper)

  16. Portfolio: A Comprehensive Method of Assessment for Postgraduates in Oral and Maxillofacial Surgery

    OpenAIRE

    Kadagad, Poornima; Kotrashetti, S. M.

    2012-01-01

    Post graduate learning and assessment is an important responsibility of an academic oral and maxillofacial surgeon. The current method of assessment for post graduate training include formative evaluation in the form of seminars, case presentations, log books and infrequently conducted end of year theory exams. End of the course theory and practical examination is a summative evaluation which awards the degree to the student based on grades obtained. Oral and maxillofacial surgery is mainly a...

  17. Silicon nanoparticles as contrast agents in the methods of optical biomedical diagnostics

    Science.gov (United States)

    Zabotnov, S. V.; Kashaev, F. V.; Shuleiko, D. V.; Gongalsky, M. B.; Golovan, L. A.; Kashkarov, P. K.; Loginova, D. A.; Agrba, P. D.; Sergeeva, E. A.; Kirillin, M. Yu

    2017-07-01

    The efficiency of light scattering by nanoparticles formed using the method of picosecond laser ablation of silicon in water and by nanoparticles of mechanically grinded mesoporous silicon is compared. The ensembles of particles of both types possess the scattering coefficients sufficient to use them as contrast agents in optical coherence tomography (OCT), particularly in the range of wavelengths 700-1000 nm, where the absorption of both silicon and most biological and mimicking tissues is small. According to the Mie theory the main contribution to the scattering in this case is made by the particles having a relatively large size (150-300 nm). In the experiments on visualising the agar phantom surface by means of OCT, the contrast of the medium boundary, provided by nanoparticles amounted to 14 dB and 30 dB for the ablated particles and the porous silicon powder, respectively. The numerical simulation of OCT images of skin in the presence of nanoparticles, confirmed the efficiency of using them as a contrast agent.

  18. Contrast computation methods for interferometric measurement of sensor modulation transfer function

    Science.gov (United States)

    Battula, Tharun; Georgiev, Todor; Gille, Jennifer; Goma, Sergio

    2018-01-01

    Accurate measurement of image-sensor frequency response over a wide range of spatial frequencies is very important for analyzing pixel array characteristics, such as modulation transfer function (MTF), crosstalk, and active pixel shape. Such analysis is especially significant in computational photography for the purposes of deconvolution, multi-image superresolution, and improved light-field capture. We use a lensless interferometric setup that produces high-quality fringes for measuring MTF over a wide range of frequencies (here, 37 to 434 line pairs per mm). We discuss the theoretical framework, involving Michelson and Fourier contrast measurement of the MTF, addressing phase alignment problems using a moiré pattern. We solidify the definition of Fourier contrast mathematically and compare it to Michelson contrast. Our interferometric measurement method shows high detail in the MTF, especially at high frequencies (above Nyquist frequency). We are able to estimate active pixel size and pixel pitch from measurements. We compare both simulation and experimental MTF results to a lens-free slanted-edge implementation using commercial software.

  19. Improvement of chirped pulse contrast using electro-optic birefringence scanning filter method

    International Nuclear Information System (INIS)

    Zeng Shuguang; Wang Xianglin; Wang Qishan; Zhang Bin; Sun Nianchun; Wang Fei

    2013-01-01

    A method using scanning filter to improve the contrast of chirped pulse is proposed, and the principle of this method is analyzed. The scanning filter is compared with the existing pulse-picking technique and nonlinear filtering technique. The scanning filter is a temporal gate that is independent on the intensity of the pulses, but on the instantaneous wavelengths of light. Taking the electro-optic birefringence scanning filter as an example, the application of scanning filter methods is illustrated. Based on numerical simulation and experimental research, it is found that the electro-optic birefringence scanning filter can eliminate a prepulse which is several hundred picoseconds before the main pulse, and the main pulse can maintain a high transmissivity. (authors)

  20. A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

    Science.gov (United States)

    Mulligan, Jeffrey B.

    2016-01-01

    Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

  1. Combination of retrograde superselective intra-arterial chemotherapy and Seldinger method in locally advanced oral cancer

    Directory of Open Access Journals (Sweden)

    Masataka Uehara

    2015-01-01

    Full Text Available The nonsurgical strategies for locally advanced oral cancer are desirable. Superselective intra-arterial infusion with radiotherapy was utilized for this purpose, and there are two types of superselective intra-arterial infusion methods: The Seldinger method and the retrograde superselective intra-arterial chemotherapy (HFT method. In one case, the HFT method was applied to locally advanced tongue cancer, and the Seldinger method was used for additional administration of cisplatin (CDDP to compensate for a lack of drug flow in the HFT method. In another case, the HFT method was applied to locally advanced lower gingival cancer. The Seldinger method was applied to metastatic lymph nodes. In both cases, additional administration of CDDP using the Seldinger method resulted in a complete response. The combination of the HFT and Seldinger methods was useful to eradicate locally advanced oral cancer because each method compensated for the defects of the other.

  2. Numerical Investigation of Vertical Cavity Lasers With High-Contrast Gratings Using the Fourier Modal Method

    DEFF Research Database (Denmark)

    Taghizadeh, Alireza; Mørk, Jesper; Chung, Il-Sug

    2016-01-01

    We explore the use of a modal expansion technique, Fourier modal method (FMM), for investigating the optical properties of vertical cavities employing high-contrast gratings (HCGs). Three techniques for determining the resonance frequency and quality factor (Q-factor) of a cavity mode are compared......, the scattering losses of several HCG-based vertical cavities with inplane heterostructures which have promising prospects for fundamental physics studies and on-chip laser applications, are investigated. This type of parametric study of 3D structures would be numerically very demanding using spatial...

  3. Simple method for quantification of gadolinium magnetic resonance imaging contrast agents using ESR spectroscopy.

    Science.gov (United States)

    Takeshita, Keizo; Kinoshita, Shota; Okazaki, Shoko

    2012-01-01

    To develop an estimation method of gadolinium magnetic resonance imaging (MRI) contrast agents, the effect of concentration of Gd compounds on the ESR spectrum of nitroxyl radical was examined. A solution of either 4-oxo-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPONE) or 4-hydroxy-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPOL) was mixed with a solution of Gd compound and the ESR spectrum was recorded. Increased concentration of gadolinium-diethylenetriamine pentaacetic acid chelate (Gd-DTPA), an MRI contrast agent, increased the peak-to-peak line widths of ESR spectra of the nitroxyl radicals, in accordance with a decrease of their signal heights. A linear relationship was observed between concentration of Gd-DTPA and line width of ESR signal, up to approximately 50 mmol/L Gd-DTPA, with a high correlation coefficient. Response of TEMPONE was 1.4-times higher than that of TEMPOL as evaluated from the slopes of the lines. The response was slightly different among Gd compounds; the slopes of calibration curves for acua[N,N-bis[2-[(carboxymethyl)[(methylcarbamoyl)methyl]amino]ethyl]glycinato(3-)]gadolinium hydrate (Gd-DTPA-BMA) (6.22 μT·L/mmol) and gadolinium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid chelate (Gd-DOTA) (6.62 μT·L/mmol) were steeper than the slope for Gd-DTPA (5.45 μT·L/mmol), whereas the slope for gadolinium chloride (4.94 μT·L/mmol) was less steep than that for Gd-DTPA. This method is simple to apply. The results indicate that this method is useful for rough estimation of the concentration of Gd contrast agents if calibration is carried out with each standard compound. It was also found that the plot of the reciprocal square root of signal height against concentrations of contrast agents could be useful for the estimation if a constant volume of sample solution is taken and measured at the same position in the ESR cavity every time.

  4. Association between traditional oral hygiene methods with tooth wear, gingival bleeding, and recession: A descriptive cross-sectional study.

    Science.gov (United States)

    Shah, Naseem; Mathur, Vijay Prakash; Jain, Veena; Logani, Ajay

    2018-01-01

    Oral hygiene maintenance is crucial for prevention of various oral diseases. Oral hygiene practices across the country vary largely and people in peri-urban and rural areas use traditional methods of oral hygiene like powders, bark, oil and salt etc. Their effect on oral soft and hard tissues need to be studied to understand their beneficial and/ or harmful effects on maintenance of oral hygiene and prevention or causation of oral diseases. This study aimed to assess the plaque-cleaning efficacy, gingival bleeding, recession and tooth wear with different traditional oral hygiene methods as compared to use of toothpaste-toothbrush, the most accepted method of oral hygiene practice. Hospital based cross sectional analytical study. Results: Total 1062 traditional oral hygiene method users were compared with same number of toothpaste-brush users. The maximum number in the former group used tooth powder (76%) as compared to other indigenous methods, such as use of bark of trees etc and out of tooth powder users; almost 75% reported using red toothpowder. The plaque scores and gingival bleeding & recession were found to be more in traditional oral hygiene method users. The toothwear was also more severe among the toothpowder users. Traditional methods were found to be inferior in plaque control as was documented by increased bleeding and gingival recession. Its effect on hard tissues of teeth was very damaging with higher tooth wear scores on all surfaces.

  5. Human Papillomavirus and Epidermal Growth Factor Receptor in Oral Cavity and Oropharyngeal Squamous Cell Carcinoma: Correlation With Dynamic Contrast-Enhanced MRI Parameters.

    Science.gov (United States)

    Choi, Yoon Seong; Park, Mina; Kwon, Hyeong Ju; Koh, Yoon Woo; Lee, Seung-Koo; Kim, Jinna

    2016-02-01

    The objective of this study was to investigate differences in dynamic contrast-enhanced MRI (DCE-MRI) parameters on the basis of the status of human papillomavirus (HPV) and epidermal growth factor receptor (EGFR) biomarkers in patients with squamous cell carcinoma (SCC) of the oral cavity and oropharynx by use of histogram analysis. A total of 22 consecutive patients with oral cavity and oropharyngeal SCC underwent DCE-MRI before receiving treatment. DCE parameter maps of the volume transfer constant (K(trans)), the flux rate constant (kep), and the extravascular extracellular volume fraction (ve) were obtained. The histogram parameters were calculated using the entire enhancing tumor volume and were compared between the patient subgroups on the basis of HPV and EGFR biomarker statuses. The cumulative histogram parameters of K(trans) and kep showed lower values in the HPV-negative and EFGR-overexpression group than in the HPV-positive EGFR-negative group. These differences were statistically significant for the mean (p = 0.009), 25th, 50th, and 75th percentile values of K(trans) and for the 25th percentile value of kep when correlated with HPV status in addition to the mean K(trans) value (p = 0.047) and kep value (p = 0.004) when correlated with EGFR status. No statistically significant difference in ve was found on the basis of HPV and EGFR status. DCE-MRI is useful for the assessment of the tumor microenvironment associated with HPV and EGFR biomarkers before treatment of patients with oral cavity and oropharyngeal SCC.

  6. Contrast-based fully automatic segmentation of white matter hyperintensities: method and validation.

    Directory of Open Access Journals (Sweden)

    Thomas Samaille

    Full Text Available White matter hyperintensities (WMH on T2 or FLAIR sequences have been commonly observed on MR images of elderly people. They have been associated with various disorders and have been shown to be a strong risk factor for stroke and dementia. WMH studies usually required visual evaluation of WMH load or time-consuming manual delineation. This paper introduced WHASA (White matter Hyperintensities Automated Segmentation Algorithm, a new method for automatically segmenting WMH from FLAIR and T1 images in multicentre studies. Contrary to previous approaches that were based on intensities, this method relied on contrast: non linear diffusion filtering alternated with watershed segmentation to obtain piecewise constant images with increased contrast between WMH and surroundings tissues. WMH were then selected based on subject dependant automatically computed threshold and anatomical information. WHASA was evaluated on 67 patients from two studies, acquired on six different MRI scanners and displaying a wide range of lesion load. Accuracy of the segmentation was assessed through volume and spatial agreement measures with respect to manual segmentation; an intraclass correlation coefficient (ICC of 0.96 and a mean similarity index (SI of 0.72 were obtained. WHASA was compared to four other approaches: Freesurfer and a thresholding approach as unsupervised methods; k-nearest neighbours (kNN and support vector machines (SVM as supervised ones. For these latter, influence of the training set was also investigated. WHASA clearly outperformed both unsupervised methods, while performing at least as good as supervised approaches (ICC range: 0.87-0.91 for kNN; 0.89-0.94 for SVM. Mean SI: 0.63-0.71 for kNN, 0.67-0.72 for SVM, and did not need any training set.

  7. A resolution-enhancing image reconstruction method for few-view differential phase-contrast tomography

    Science.gov (United States)

    Guan, Huifeng; Anastasio, Mark A.

    2017-03-01

    It is well-known that properly designed image reconstruction methods can facilitate reductions in imaging doses and data-acquisition times in tomographic imaging. The ability to do so is particularly important for emerging modalities such as differential X-ray phase-contrast tomography (D-XPCT), which are currently limited by these factors. An important application of D-XPCT is high-resolution imaging of biomedical samples. However, reconstructing high-resolution images from few-view tomographic measurements remains a challenging task. In this work, a two-step sub-space reconstruction strategy is proposed and investigated for use in few-view D-XPCT image reconstruction. It is demonstrated that the resulting iterative algorithm can mitigate the high-frequency information loss caused by data incompleteness and produce images that have better preserved high spatial frequency content than those produced by use of a conventional penalized least squares (PLS) estimator.

  8. A novel method for contrast-to-noise ratio (CNR) evaluation of digital mammography detectors

    International Nuclear Information System (INIS)

    Baldelli, P.; Phelan, N.; Egan, G.

    2009-01-01

    The purpose of this study was to test a new, simple method of evaluating the contrast-to-noise ratio (CNR) over the entire image field of a digital detector and to compare different mammography systems. Images were taken under clinical exposure conditions for a range of simulated breast thicknesses using poly(methyl methacrylate) (PMMA). At each PMMA thickness, a second image which included an additional 0.2-mm Al sheet was also acquired. Image processing software was used to calculate the CNR in multiple regions of interest (ROI) covering the entire area of the detector in order to obtain a 'CNR image'. Five detector types were evaluated, two CsI-αSi (GE Healthcare) flat panel systems, one αSe (Hologic) flat panel system and a two generations of scanning photon counting digital detectors (Sectra). Flat panel detectors exhibit better CNR uniformity compared with the first-generation scanning photon counting detector in terms of mean pixel value variation. However, significant improvement in CNR uniformity was observed for the next-generation scanning detector. The method proposed produces a map of the CNR and a measurement of uniformity throughout the entire image field of the detector. The application of this method enables quality control measurement of individual detectors and a comparison of detectors using different technologies. (orig.)

  9. Mathematical imaging methods for mitosis analysis in live-cell phase contrast microscopy.

    Science.gov (United States)

    Grah, Joana Sarah; Harrington, Jennifer Alison; Koh, Siang Boon; Pike, Jeremy Andrew; Schreiner, Alexander; Burger, Martin; Schönlieb, Carola-Bibiane; Reichelt, Stefanie

    2017-02-15

    In this paper we propose a workflow to detect and track mitotic cells in time-lapse microscopy image sequences. In order to avoid the requirement for cell lines expressing fluorescent markers and the associated phototoxicity, phase contrast microscopy is often preferred over fluorescence microscopy in live-cell imaging. However, common specific image characteristics complicate image processing and impede use of standard methods. Nevertheless, automated analysis is desirable due to manual analysis being subjective, biased and extremely time-consuming for large data sets. Here, we present the following workflow based on mathematical imaging methods. In the first step, mitosis detection is performed by means of the circular Hough transform. The obtained circular contour subsequently serves as an initialisation for the tracking algorithm based on variational methods. It is sub-divided into two parts: in order to determine the beginning of the whole mitosis cycle, a backwards tracking procedure is performed. After that, the cell is tracked forwards in time until the end of mitosis. As a result, the average of mitosis duration and ratios of different cell fates (cell death, no division, division into two or more daughter cells) can be measured and statistics on cell morphologies can be obtained. All of the tools are featured in the user-friendly MATLAB®Graphical User Interface MitosisAnalyser. Copyright © 2017. Published by Elsevier Inc.

  10. ZEUS: a cophasing sensor based on the Zernike phase contrast method

    Science.gov (United States)

    Dohlen, Kjetil; Langlois, Maud; Lanzoni, Patrick; Mazzanti, Silvio; Vigan, Arthur; Montoya, Luzma; Hernandez, Elvio; Reyes, Marcos; Surdej, Isabel; Yaitskova, Natalya

    2006-06-01

    We describe the ZEUS phasing camera for future extremely large telescopes (ELTs) based on the Zernike phase contrast method. A prototype instrument is under construction for implementation in the Active Phasing Experiment (APE), a VLT test bed scheduled for operation in 2007. The paper describes theoretical aspects of the method and its experimental validation, as well as the instrumental implementation for APE. Aspects of its implementation in an ELT are also discussed. While the classical Zernike method uses a phase mask with diameter approximately equal to the Airy disk, we employ a mask the size of the seeing disk. This allows us to overcome the problems related to atmospheric turbulence, whose low spatial frequency phase errors are much larger than the co-phasing errors to be measured. The thickness (OPD) of the mask can be set to lambda/4 - as in the classical case - for maximum signal strength, but for initial phasing where phase errors are much larger than the sensor's linear range (+/-lambda/4), a thinner mask produces a cleaner signal more easily exploitable, leaving the signal analysis more robust. A multi wavelength approach is implemented in order to extend the capture range of the sensor, and the ultimate precision is reached using an iterative approach. End-to-end simulations indicating an achievable precision within the required precision will be shown.

  11. 18F-FDG-PET/CT parameters as imaging biomarkers in oral cavity squamous cell carcinoma, is visual analysis of PET and contrast enhanced CT better than the numbers?

    Energy Technology Data Exchange (ETDEWEB)

    Kendi, A.Tuba, E-mail: ayse.kendi@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Corey, Amanda [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Magliocca, Kelly R. [Department of Pathology, Emory University, Atlanta, GA (United States); Nickleach, Dana C. [Biostatistics & Bioinformatics Shared Resource at Winship Cancer Institute of Emory University, Atlanta, GA (United States); Galt, James [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Switchenko, Jeffrey M. [Biostatistics & Bioinformatics Shared Resource at Winship Cancer Institute of Emory University, Atlanta, GA (United States); El-Deiry, Mark W.; Wadsworth, J. Trad [Otolaryngology Head and Neck Surgery, Emory University, Atlanta, GA (United States); Hudgins, Patricia A. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Saba, Nabil F. [Hematology Oncology, Winship Cancer Institute of Emory University, Atlanta, GA (United States); Schuster, David M. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States)

    2015-06-15

    Highlights: • Highlights of our study were the significant association of higher T stage of oral cavity squamous cell carcinoma with PET/CT parameters. • This could be an important finding in cases where it is difficult to decide on T stage by CT only. • We found a significant association between ring/heterogeneous enhancement pattern of (either primary or nodal or both) oral cavity squamous cell carcinoma at contrast enhanced CT and poor prognosis. • This could be related to hypoxia, which is a known reason for therapy resistance. Hence therapies can be tailored in the feature depending on enhancement pattern on contrast enhanced CT. - Abstract: Purpose: This study was designed to seek associations between positron emission tomography/computed tomography (PET/CT) parameters, contrast enhanced neck computed tomography (CECT) and pathological findings, and to determine the potential prognostic value of PET/CT and CECT parameters in oral cavity squamous cell carcinoma (OCSCC). Materials and method: 36 OCSCC patients underwent staging PET/CT and 30/36 of patients had CECT. PET/CT parameters were measured for the primary tumor and the hottest involved node, including maximum, mean, and peak standardized uptake values (SUV max, SUV mean, and SUV peak), metabolic tumor volume (MTV), total lesion glycolysis (TLG), standardized added metabolic activity (SAM), and normalized standardized added metabolic activity (N SAM). Qualitative assessment of PET/CT and CECT were also performed. Pathological outcomes included: perineural invasion, lymphovascular invasion, nodal extracapsular spread, grade, pathologic T and N stages. Multivariable logistic regression models were fit for each parameter and outcome adjusting for potentially confounding variables. Multivariable Cox proportional hazards models were used for progression free survival (PFS), locoregional recurrence free survival (LRFS), overall survival (OS) and distant metastasis free survival (DMFS). Results: In

  12. 18F-FDG-PET/CT parameters as imaging biomarkers in oral cavity squamous cell carcinoma, is visual analysis of PET and contrast enhanced CT better than the numbers?

    International Nuclear Information System (INIS)

    Kendi, A.Tuba; Corey, Amanda; Magliocca, Kelly R.; Nickleach, Dana C.; Galt, James; Switchenko, Jeffrey M.; El-Deiry, Mark W.; Wadsworth, J. Trad; Hudgins, Patricia A.; Saba, Nabil F.; Schuster, David M.

    2015-01-01

    Highlights: • Highlights of our study were the significant association of higher T stage of oral cavity squamous cell carcinoma with PET/CT parameters. • This could be an important finding in cases where it is difficult to decide on T stage by CT only. • We found a significant association between ring/heterogeneous enhancement pattern of (either primary or nodal or both) oral cavity squamous cell carcinoma at contrast enhanced CT and poor prognosis. • This could be related to hypoxia, which is a known reason for therapy resistance. Hence therapies can be tailored in the feature depending on enhancement pattern on contrast enhanced CT. - Abstract: Purpose: This study was designed to seek associations between positron emission tomography/computed tomography (PET/CT) parameters, contrast enhanced neck computed tomography (CECT) and pathological findings, and to determine the potential prognostic value of PET/CT and CECT parameters in oral cavity squamous cell carcinoma (OCSCC). Materials and method: 36 OCSCC patients underwent staging PET/CT and 30/36 of patients had CECT. PET/CT parameters were measured for the primary tumor and the hottest involved node, including maximum, mean, and peak standardized uptake values (SUV max, SUV mean, and SUV peak), metabolic tumor volume (MTV), total lesion glycolysis (TLG), standardized added metabolic activity (SAM), and normalized standardized added metabolic activity (N SAM). Qualitative assessment of PET/CT and CECT were also performed. Pathological outcomes included: perineural invasion, lymphovascular invasion, nodal extracapsular spread, grade, pathologic T and N stages. Multivariable logistic regression models were fit for each parameter and outcome adjusting for potentially confounding variables. Multivariable Cox proportional hazards models were used for progression free survival (PFS), locoregional recurrence free survival (LRFS), overall survival (OS) and distant metastasis free survival (DMFS). Results: In

  13. Systems and methods for separating particles utilizing engineered acoustic contrast capture particles

    Science.gov (United States)

    Kaduchak, Gregory; Ward, Michael D.

    2018-03-06

    An apparatus for separating particles from a medium includes a capillary defining a flow path therein that is in fluid communication with a medium source. The medium source includes engineered acoustic contrast capture particle having a predetermined acoustic contrast. The apparatus includes a vibration generator that is operable to produce at least one acoustic field within the flow path. The acoustic field produces a force potential minima for positive acoustic contrast particles and a force potential minima for negative acoustic contrast particles in the flow path and drives the engineered acoustic contrast capture particles to either the force potential minima for positive acoustic contrast particles or the force potential minima for negative acoustic contrast particles.

  14. Transferability of hydrological models and ensemble averaging methods between contrasting climatic periods

    Science.gov (United States)

    Broderick, Ciaran; Matthews, Tom; Wilby, Robert L.; Bastola, Satish; Murphy, Conor

    2016-10-01

    Understanding hydrological model predictive capabilities under contrasting climate conditions enables more robust decision making. Using Differential Split Sample Testing (DSST), we analyze the performance of six hydrological models for 37 Irish catchments under climate conditions unlike those used for model training. Additionally, we consider four ensemble averaging techniques when examining interperiod transferability. DSST is conducted using 2/3 year noncontinuous blocks of (i) the wettest/driest years on record based on precipitation totals and (ii) years with a more/less pronounced seasonal precipitation regime. Model transferability between contrasting regimes was found to vary depending on the testing scenario, catchment, and evaluation criteria considered. As expected, the ensemble average outperformed most individual ensemble members. However, averaging techniques differed considerably in the number of times they surpassed the best individual model member. Bayesian Model Averaging (BMA) and the Granger-Ramanathan Averaging (GRA) method were found to outperform the simple arithmetic mean (SAM) and Akaike Information Criteria Averaging (AICA). Here GRA performed better than the best individual model in 51%-86% of cases (according to the Nash-Sutcliffe criterion). When assessing model predictive skill under climate change conditions we recommend (i) setting up DSST to select the best available analogues of expected annual mean and seasonal climate conditions; (ii) applying multiple performance criteria; (iii) testing transferability using a diverse set of catchments; and (iv) using a multimodel ensemble in conjunction with an appropriate averaging technique. Given the computational efficiency and performance of GRA relative to BMA, the former is recommended as the preferred ensemble averaging technique for climate assessment.

  15. Viva Voce (Oral Examination) as an Assessment Method: Insights from Marketing Students

    Science.gov (United States)

    Pearce, Glenn; Lee, Geoffrey

    2009-01-01

    Viva voce (viva) or oral examinations are widely used in medical education, clinical examinations, and doctoral defenses, yet the assessment method is seldom adopted by university marketing departments. Correspondingly, the marketing education literature makes no reference to vivas as an alternative academic assessment technique. This research…

  16. Characterization of Breast Masses Using a New Method of Ultrasound Contrast Agent Imaging in 3D Mapping of Vascular Anomalies

    National Research Council Canada - National Science Library

    LeCarpentier, Gerald

    2002-01-01

    .... The purpose of this work is to develop an innovative dual-transducer method to control the destruction and imaging of ultrasound contrast during 3D ultrasound scanning of suspicious breast masses...

  17. Comparative evaluation of the fecal-tagging quality in CT colonography: barium vs. iodinated oral contrast agent.

    Science.gov (United States)

    Nagata, Koichi; Singh, Anand Kumar; Sangwaiya, Minal Jagtiani; Näppi, Janne; Zalis, Michael E; Cai, Wenli; Yoshida, Hiroyuki

    2009-11-01

    The purpose of this evaluation was to compare the tagging quality of a barium-based regimen with that of iodine-based regimens for computed tomographic (CT) colonography. Tagging quality was assessed retrospectively in three different types of fecal-tagging CT colonographic cases: 24 barium-based cases, 22 nonionic iodine-based cases, and 24 ionic iodine-based cases. For the purpose of evaluation, the large intestine was divided into six segments, and the tagging homogeneity of a total of 420 segments (70 patients) was graded by three blinded readers from 0 (heterogeneous) to 4 (homogeneous). For barium-based cases, the average score for the three readers was 2.4, whereas it was 3.4 for nonionic iodine and 3.6 for ionic iodine. The percentages of segments that were assigned scores of 4 (excellent tagging [100%]) were 11.6%, 61.9%, and 72.9% for the barium-based, nonionic iodine-based, and ionic iodine-based regimens, respectively. The homogeneity scores of iodine-based fecal-tagging regimens were significantly higher than those of the barium-based fecal-tagging regimen (P barium-based regimen (P barium-based fecal-tagging regimen. Iodine-based fecal-tagging regimens can provide an appropriate method for use in nonlaxative or minimum-laxative CT colonography.

  18. Multilevel markov chain monte carlo method for high-contrast single-phase flow problems

    KAUST Repository

    Efendiev, Yalchin R.

    2014-12-19

    In this paper we propose a general framework for the uncertainty quantification of quantities of interest for high-contrast single-phase flow problems. It is based on the generalized multiscale finite element method (GMsFEM) and multilevel Monte Carlo (MLMC) methods. The former provides a hierarchy of approximations of different resolution, whereas the latter gives an efficient way to estimate quantities of interest using samples on different levels. The number of basis functions in the online GMsFEM stage can be varied to determine the solution resolution and the computational cost, and to efficiently generate samples at different levels. In particular, it is cheap to generate samples on coarse grids but with low resolution, and it is expensive to generate samples on fine grids with high accuracy. By suitably choosing the number of samples at different levels, one can leverage the expensive computation in larger fine-grid spaces toward smaller coarse-grid spaces, while retaining the accuracy of the final Monte Carlo estimate. Further, we describe a multilevel Markov chain Monte Carlo method, which sequentially screens the proposal with different levels of approximations and reduces the number of evaluations required on fine grids, while combining the samples at different levels to arrive at an accurate estimate. The framework seamlessly integrates the multiscale features of the GMsFEM with the multilevel feature of the MLMC methods following the work in [26], and our numerical experiments illustrate its efficiency and accuracy in comparison with standard Monte Carlo estimates. © Global Science Press Limited 2015.

  19. Artifact reduction method in ultrasound-guided diffuse optical tomography using exogenous contrast agents

    Science.gov (United States)

    Ardeshirpour, Yasaman; Biswal, Nrusingh; Aguirre, Andres; Zhu, Quing

    2011-04-01

    In diffuse optical tomography (DOT), a typical perturbation approach requires two sets of measurements obtained at the lesion breast (lesion or target site) and a contra-lateral location of the normal breast (reference site) for image reconstruction. For patients who have a small amount of breast tissue, the chest-wall underneath the breast tissue at both sites affects the imaging results. In this group of patients, the perturbation, which is the difference between measurements obtained at the lesion and reference sites, may include the information of background mismatch which can generate artifacts or affect the reconstructed quantitative absorption coefficient of the lesion. Also, for patients who have a single breast due to prior surgery, the contra-lateral reference is not available. To improve the DOT performance or overcome its limitation, we introduced a new method based on an exogenous contrast agent and demonstrate its performance using animal models. Co-registered ultrasound was used to guide the lesion localization. The results have shown that artifacts caused by background mismatch can be reduced significantly by using this new method.

  20. Comparative evaluation of audio and audio - tactile methods to improve oral hygiene status of visually impaired school children

    OpenAIRE

    R Krishnakumar; Swarna Swathi Silla; Sugumaran K Durai; Mohan Govindarajan; Syed Shaheed Ahamed; Logeshwari Mathivanan

    2016-01-01

    Background: Visually impaired children are unable to maintain good oral hygiene, as their tactile abilities are often underdeveloped owing to their visual disturbances. Conventional brushing techniques are often poorly comprehended by these children and hence, it was decided to evaluate the effectiveness of audio and audio-tactile methods in improving the oral hygiene of these children. Objective: To evaluate and compare the effectiveness of audio and audio-tactile methods in improving oral h...

  1. Oral rinse as a potential method to culture Candida isolate from AIDS patients

    Directory of Open Access Journals (Sweden)

    Desiana Radithia

    2011-12-01

    Full Text Available Background: Candida isolate is easily sampled from oral cavity by swabbing directly on the candidiasis lesion, to be smeared onto slides for direct examination or cultured in a growth medium. This method is by far the gold standard for defining candidiasis diagnosis. However it is difficult to apply on sensitive patients and almost impossible on patients showing no clinical appearance of oral candidiasis. AIDS patients are very prone to candida infection and have a tendency of repetitive infection involving mixed species. As many candida species show different susceptibility to anti-fungal agents, it is necessary to identify the species causing the infection in the management of oral candidiasis. Oral rinse is a suggested method to obtain candida isolate to be cultured for further analysis such as species identification. This method is simple and less risky on infection transmission as less tools are required in the procedure. Purpose: This study aimed to assess the application of oral rinse as an alternative method to culture Candida isolate from AIDS patients. Methods: A cross-sectional observative study was conducted in HIV/AIDS in-Patient Facility of Intermediate Care Unit for Infection Disease, Dr. Soetomo Hospital Surabaya. Fourteen stadium 4 AIDS patients matching criteria were swabbed on 1/3-posterior of the tongue, and then given 10 ml phosphate buffer saline to rinse vigorously for 15 seconds. Both specimens were cultured on Sabouraud’s dextrose agar and colony growth was observed. Results: Candida colonies were able to grow from all 14 isolates (100% by both methods. Qualitatively, cultures from oral rinse specimens were more populated than cultures from swab specimens. Conclusion: Oral rinse is an applicable technique to obtain Candida species isolate. This technique is safe, easy, non-invasive, and needs less tools therefore less risky for HIV transmission.Latar belakang: Isolat Candida mudah diambil dengan cara mengusap lesi

  2. Evaluation of an acute oral gavage method for assessment of pesticide toxicity in terrestrial amphibians.

    Science.gov (United States)

    Fort, Douglas J; Mathis, Michael B; Kee, Faith; Whatling, Paul; Clerkin, David; Staveley, Jane; Habig, Clifford

    2018-02-01

    Development of an acute oral toxicity test with a terrestrial-phase amphibian was considered necessary to remove the uncertainty within the field of agrochemical risk assessments. The bullfrog (Lithobates catesbeianus) was selected for use as it is a representative of the family Ranidae and historically this species has been used as an amphibian test model species. Prior to definitive study, oral gavage methods were developed with fenthion and tetraethyl pyrophosphate. Dimethoate and malathion were subsequently tested with both male and female juvenile bullfrogs in comprehensive acute oral median lethal dose (LD50) studies. Juvenile bullfrogs were administered a single dose of the test article via oral gavage of a single gelatin capsule of dimethoate technical (dimethoate) or neat liquid Fyfanon ® Technical (synonym malathion), returned to their respective aquaria, and monitored for survival for 14 d. The primary endpoint was mortality, whereas behavioral responses, food consumption, body weight, and snout-vent length (SVL) were used to evaluate indications of sublethal toxicity (secondary endpoints). Acute oral LD50 values (95% fiducial interval) for dimethoate were 1459 (1176-1810, males) and 1528 (1275-1831, females), and for malathion they were 1829 (1480-2259, males) and 1672 (1280-2183, females) mg active substance/kg body weight, respectively. Based on the results of these studies, the methodology for the acute oral gavage administration of test items to terrestrial-phase amphibians was demonstrated as being a practical method of providing data for risk assessments. Environ Toxicol Chem 2018;37:436-450. © 2017 SETAC. © 2017 SETAC.

  3. Development and validation of a dissolution method using HPLC for diclofenac potassium in oral suspension

    Directory of Open Access Journals (Sweden)

    Alexandre Machado Rubim

    2014-04-01

    Full Text Available The present study describes the development and validation of an in vitro dissolution method for evaluation to release diclofenac potassium in oral suspension. The dissolution test was developed and validated according to international guidelines. Parameters like linearity, specificity, precision and accuracy were evaluated, as well as the influence of rotation speed and surfactant concentration on the medium. After selecting the best conditions, the method was validated using apparatus 2 (paddle, 50-rpm rotation speed, 900 mL of water with 0.3% sodium lauryl sulfate (SLS as dissolution medium at 37.0 ± 0.5°C. Samples were analyzed using the HPLC-UV (PDA method. The results obtained were satisfactory for the parameters evaluated. The method developed may be useful in routine quality control for pharmaceutical industries that produce oral suspensions containing diclofenac potassium.

  4. Iopamidol as an oral contrast media for computed tomography: a taste comparison to iohexol, diatrizoate sodium, and barium sulfate.

    Science.gov (United States)

    Rogers, Douglas; Sheth, Chandni; Eisenmenger, Laura; Mignogna, Eugene; Winter, Thomas

    2017-12-01

    The objective of this study is to compare the palatability of iopamidol and iohexol. This was a blinded and randomized trial in which fifty healthy subjects taste tested iopamidol (Isovue, Bracco Diagnostics), iohexol (Omnipaque, GE Healthcare), diatrizoate meglumine and diatrizoate sodium solution (Gastrografin, Bracco Diagnostics), and barium sulfate suspension 2.1% w/v, 2.0% w/w (READI-CAT2, E-Z-EM). Participants scored palatability on a continuous scale from 0 to 40 (0 = intolerable, 10 = unpleasant but tolerable, 20 = neutral, 30 = kind of like, 40 = strongly like). Mean scores (SD/SEM) for the contrast agents (n = 50) were iopamidol = 21.0 (8.4/1.2); iohexol = 21.8 (7.1/1.0); Gastrografin = 16.8 (9.6/1.4); and barium = 23.7 (9.1/1.3). One-way ANOVA equality of means test shows rejection of the hypothesis that the means are equal (F* = 6.550, p = .000). Post hoc testing demonstrates Gastrografin to be significantly less preferred to barium (p = .000) and iohexol (p = .012). No difference was found between iopamidol and iohexol (p = .959). One-way ANOVA equality of means test of just iopamidol, iohexol, and barium does not reject the hypothesis that means are equal (F* = 1.778 and p = .174). There is no significant difference in palatability between iopamidol and iohexol, supporting the use of iopamidol as a viable alternative to iohexol as an oral contrast agent.

  5. Adaptive optics in spinning disk microscopy: improved contrast and brightness by a simple and fast method.

    Science.gov (United States)

    Fraisier, V; Clouvel, G; Jasaitis, A; Dimitrov, A; Piolot, T; Salamero, J

    2015-09-01

    Multiconfocal microscopy gives a good compromise between fast imaging and reasonable resolution. However, the low intensity of live fluorescent emitters is a major limitation to this technique. Aberrations induced by the optical setup, especially the mismatch of the refractive index and the biological sample itself, distort the point spread function and further reduce the amount of detected photons. Altogether, this leads to impaired image quality, preventing accurate analysis of molecular processes in biological samples and imaging deep in the sample. The amount of detected fluorescence can be improved with adaptive optics. Here, we used a compact adaptive optics module (adaptive optics box for sectioning optical microscopy), which was specifically designed for spinning disk confocal microscopy. The module overcomes undesired anomalies by correcting for most of the aberrations in confocal imaging. Existing aberration detection methods require prior illumination, which bleaches the sample. To avoid multiple exposures of the sample, we established an experimental model describing the depth dependence of major aberrations. This model allows us to correct for those aberrations when performing a z-stack, gradually increasing the amplitude of the correction with depth. It does not require illumination of the sample for aberration detection, thus minimizing photobleaching and phototoxicity. With this model, we improved both signal-to-background ratio and image contrast. Here, we present comparative studies on a variety of biological samples. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  6. Multiscale finite element methods for high-contrast problems using local spectral basis functions

    KAUST Repository

    Efendiev, Yalchin

    2011-02-01

    In this paper we study multiscale finite element methods (MsFEMs) using spectral multiscale basis functions that are designed for high-contrast problems. Multiscale basis functions are constructed using eigenvectors of a carefully selected local spectral problem. This local spectral problem strongly depends on the choice of initial partition of unity functions. The resulting space enriches the initial multiscale space using eigenvectors of local spectral problem. The eigenvectors corresponding to small, asymptotically vanishing, eigenvalues detect important features of the solutions that are not captured by initial multiscale basis functions. Multiscale basis functions are constructed such that they span these eigenfunctions that correspond to small, asymptotically vanishing, eigenvalues. We present a convergence study that shows that the convergence rate (in energy norm) is proportional to (H/Λ*)1/2, where Λ* is proportional to the minimum of the eigenvalues that the corresponding eigenvectors are not included in the coarse space. Thus, we would like to reach to a larger eigenvalue with a smaller coarse space. This is accomplished with a careful choice of initial multiscale basis functions and the setup of the eigenvalue problems. Numerical results are presented to back-up our theoretical results and to show higher accuracy of MsFEMs with spectral multiscale basis functions. We also present a hierarchical construction of the eigenvectors that provides CPU savings. © 2010.

  7. Computed tomography of kidney with diuretics. A method for avoiding artifact due to nonionic contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hiromura, Tadao; Terae, Satoshi; Takamura, Akio; Mizoe, Junetsu (Obihiro Kosei Hospital, Hokkaido (Japan)); Morita, Yutaka; Irie, Goro

    1989-07-01

    We devised a method for avoiding beam-hardening artifacts, which interfere with enhanced CT images of kidney due to nonionic contrast medium. The radiographic effect and the frequency of beam-hardening artifacts on enhanced CT of kidney were studied by prospective comparison among three groups: a group of 20 patients examined with furosemide (f-d.CT), a group of 20 patients examined without diuretics (non-d.CT) and a group of 20 patients examined after water intake (w-d.CT). In all patients of f-d.CT group, the renal parenchyma from the cortex to the papilla was almost evently enhanced, free from artifacts. The density of the renal papilla and pelvis in non-d.CT and w-d.CT groups was significantly higher than that in f-d.CT group, and artifacts were also observed in 14 (70%) of non-d.CT group and 12 (60%) of w.d.CT group, respectively. Satisfactory CT of kidney free from artifacts was obtained by f-d.CT, providing easy evaluation of renal pelvic or peripelvic lesions. In conclusion, this technique can be used in those pathologic cases of renal pelvis or peripelvic region, that are not clear on routine CT because of artifacts. (author).

  8. Contrast enhancement kinetics of normal breast parenchyma in dynamic MR mammography: effects of menopausal status, oral contraceptives, and postmenopausal hormone therapy

    International Nuclear Information System (INIS)

    Hegenscheid, Katrin; Seipel, Rebecca; Laqua, Rene; Hosten, Norbert; Puls, Ralf; Schmidt, Carsten O.; Ohlinger, Ralf

    2012-01-01

    To investigate effects of menopausal status, oral contraceptives (OC), and postmenopausal hormone therapy (HT) on normal breast parenchymal contrast enhancement (CE) and non-mass-like enhancing areas in magnetic resonance mammography (MRM). A total of 459 female volunteers (mean age 49.1 ± 12.5 years) underwent T1-weighted 3D MRM 1-5 min after bolus injection of gadobutrol. Quantitative analysis was performed in normal breast parenchyma by manually tracing regions of interest and calculating percentage CE. Semiquantitative analysis was performed in non-mass-like enhancing areas, and signal intensity changes were characterised by five predefined kinetic curve types. The influence of OC (n = 69) and HT (n = 24) on CE was studied using random effects models. Breast parenchymal enhancement was significantly higher in premenopausal than in postmenopausal women (P < 0.001). CE decreased significantly with the use of OC (P = 0.01), while HT had negligible effects (P = 0.52). Prevalence of kinetic curve types of non-mass-like enhancement differed strongly between pre- and postmenopausal women (P < 0.0001), but was similar in OC users and non-OC users (P = 0.61) as well as HT users and non-HT users (P = 0.77). Normal breast parenchymal enhancement and non-mass-like enhancing areas were strongly affected by menopausal status, while they were not affected by HT use and only moderately by OC use. (orig.)

  9. Contrast enhancement kinetics of normal breast parenchyma in dynamic MR mammography: effects of menopausal status, oral contraceptives, and postmenopausal hormone therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hegenscheid, Katrin; Seipel, Rebecca; Laqua, Rene; Hosten, Norbert; Puls, Ralf [Ernst-Moritz-Arndt University Medical Center Greifswald, Department of Diagnostic Radiology and Neuroradiology, Greifswald (Germany); Schmidt, Carsten O. [Ernst-Moritz-Arndt University Medical Center Greifswald, Institute for Community Medicine, Greifswald (Germany); Ohlinger, Ralf [Ernst-Moritz-Arndt University Medical Center Greifswald, Department of Gynecology and Obstetrics, Greifswald (Germany)

    2012-12-15

    To investigate effects of menopausal status, oral contraceptives (OC), and postmenopausal hormone therapy (HT) on normal breast parenchymal contrast enhancement (CE) and non-mass-like enhancing areas in magnetic resonance mammography (MRM). A total of 459 female volunteers (mean age 49.1 {+-} 12.5 years) underwent T1-weighted 3D MRM 1-5 min after bolus injection of gadobutrol. Quantitative analysis was performed in normal breast parenchyma by manually tracing regions of interest and calculating percentage CE. Semiquantitative analysis was performed in non-mass-like enhancing areas, and signal intensity changes were characterised by five predefined kinetic curve types. The influence of OC (n = 69) and HT (n = 24) on CE was studied using random effects models. Breast parenchymal enhancement was significantly higher in premenopausal than in postmenopausal women (P < 0.001). CE decreased significantly with the use of OC (P = 0.01), while HT had negligible effects (P = 0.52). Prevalence of kinetic curve types of non-mass-like enhancement differed strongly between pre- and postmenopausal women (P < 0.0001), but was similar in OC users and non-OC users (P = 0.61) as well as HT users and non-HT users (P = 0.77). Normal breast parenchymal enhancement and non-mass-like enhancing areas were strongly affected by menopausal status, while they were not affected by HT use and only moderately by OC use. (orig.)

  10. Accuracy of CT chest without oral contrast for ruling out esophageal perforation using fluoroscopic esophagography as reference standard: a retrospective study.

    Science.gov (United States)

    Awais, Muhammad; Qamar, Saqib; Rehman, Abdul; Baloch, Noor Ul-Ain; Shafqat, Gulnaz

    2018-02-26

    Esophageal perforation has a high mortality rate. Fluoroscopic esophagography (FE) is the procedure of choice for diagnosing esophageal perforation. However, FE can be difficult to perform in seriously ill patients. We retrospectively reviewed charts and scans of all patients who had undergone thoracic CT (TCT) without oral contrast and FE for suspicion of esophageal perforation at our hospital between October, 2010 and December, 2015. Scans were interpreted by a single consultant radiologist having > 5 years of relevant experience. Statistical analysis was performed using SPSS version 20. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TCT were computed using FE as reference standard. Of 122 subjects, 106 (83%) were male and their median age was 42 [inter-quartile range (IQR) 29-53] years. Esophageal perforation was evident on FE in 15 (8%) cases. Sensitivity, specificity, PPV and NPV of TCT for detecting esophageal perforation were 100, 54.6, 23.4 and 100%, respectively. When TCT was negative (n = 107), an alternative diagnosis was evident in 65 cases. Thoracic computed tomography (TCT) had 100% sensitivity and negative predictive value for excluding esophageal perforation. FE may be omitted in patients who have no evidence of mediastinal collection, pneumomediastinum or esophageal wall defect on TCT. However, in the presence of any of these features, FE is still necessary to confirm or exclude the presence of an esophageal perforation.

  11. Myocardial blood flow estimates from dynamic contrast-enhanced magnetic resonance imaging: three quantitative methods

    Science.gov (United States)

    Borrazzo, Cristian; Galea, Nicola; Pacilio, Massimiliano; Altabella, Luisa; Preziosi, Enrico; Carnì, Marco; Ciolina, Federica; Vullo, Francesco; Francone, Marco; Catalano, Carlo; Carbone, Iacopo

    2018-02-01

    Dynamic contrast-enhanced cardiovascular magnetic resonance imaging can be used to quantitatively assess the myocardial blood flow (MBF), recovering the tissue impulse response function for the transit of a gadolinium bolus through the myocardium. Several deconvolution techniques are available, using various models for the impulse response. The method of choice may influence the results, producing differences that have not been deeply investigated yet. Three methods for quantifying myocardial perfusion have been compared: Fermi function modelling (FFM), the Tofts model (TM) and the gamma function model (GF), with the latter traditionally used in brain perfusion MRI. Thirty human subjects were studied at rest as well as under cold pressor test stress (submerging hands in ice-cold water), and a single bolus of gadolinium weighing 0.1  ±  0.05 mmol kg-1 was injected. Perfusion estimate differences between the methods were analysed by paired comparisons with Student’s t-test, linear regression analysis, and Bland-Altman plots, as well as also using the two-way ANOVA, considering the MBF values of all patients grouped according to two categories: calculation method and rest/stress conditions. Perfusion estimates obtained by various methods in both rest and stress conditions were not significantly different, and were in good agreement with the literature. The results obtained during the first-pass transit time (20 s) yielded p-values in the range 0.20-0.28 for Student’s t-test, linear regression analysis slopes between 0.98-1.03, and R values between 0.92-1.01. From the Bland-Altman plots, the paired comparisons yielded a bias (and a 95% CI)—expressed as ml/min/g—for FFM versus TM, -0.01 (-0.20, 0.17) or 0.02 (-0.49, 0.52) at rest or under stress respectively, for FFM versus GF, -0.05 (-0.29, 0.20) or  -0.07 (-0.55, 0.41) at rest or under stress, and for TM versus GF, -0.03 (-0.30, 0.24) or  -0.09 (-0.43, 0.26) at rest or under stress. With the

  12. A new formulation for orally disintegrating tablets using a suspension spray-coating method.

    Science.gov (United States)

    Okuda, Y; Irisawa, Y; Okimoto, K; Osawa, T; Yamashita, S

    2009-12-01

    The aim of this study was to design a new orally disintegrating tablet (ODT) that has high tablet hardness and a fast oral disintegration rate using a new preparation method. To obtain rapid disintegration granules (RDGs), a saccharide, such as trehalose, mannitol, or lactose, was spray-coated with a suspension of corn starch using a fluidized-bed granulator (suspension method). As an additional disintegrant, crospovidone, light anhydrous silicic acid, or hydroxypropyl starch was also included in the suspension. The RDGs obtained possessed extremely large surface areas, narrow particle size distribution, and numerous micro-pores. When tabletting these RDGs, it was found that the RDGs increased tablet hardness by decreasing plastic deformation and increasing the contact frequency between granules. In all tablets, a linear relationship was observed between tablet hardness and oral disintegration time. From each linear correlation line, a slope (D/H value) and an intercept (D/H(0) value) were calculated. Tablets with small D/H and D/H(0) values could disintegrate immediately in the oral cavity regardless of the tablet hardness and were considered to be appropriate for ODTs. Therefore, these values were used as key parameters to select better ODTs. Of all the RDGs prepared in this study, mannitol spray-coated with a suspension of corn starch and crospovidone (2.5:1 w/w ratio) showed most appropriate properties for ODTs; fast in vivo oral disintegration time, and high tablet hardness. In conclusion, this simple method to prepare superior formulations for new ODTs was established by spray-coating mannitol with a suspension of appropriate disintegrants.

  13. X-ray imaging with monochromatic synchrotron radiation. Fluorescent and phase-contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-05-01

    To obtain the high sensitive x-ray images of biomedical object, new x-ray imaging techniques using fluorescent x-ray and phase-contrast x-ray are being developed in Japan. Fluorescent x-ray CT can detect very small amounts of specific elements in the order of ppm at one pixel, whereas phase-contrast x-ray imaging with interferometer can detect minute differences of biological object. Here, our recent experimental results are presented. (author)

  14. The Use of Buccal Fat Pad in the Treatment of Oral Submucous Fibrosis: A Newer Method

    Directory of Open Access Journals (Sweden)

    K. Saravanan

    2012-01-01

    Full Text Available Purpose of the study. This study was to evaluate the use of buccal fat pad as an interpositioning material in surgical management of oral sub mucous fibrosis. Materials and methods. A series of 8 cases with proven oral sub mucous fibrosis, with mouth opening less than 20 mm, involving the buccal mucosa were treated surgically in the Department of Oral and Maxillofacial Surgery, College of Dental Surgery, Saveetha University, Chennai. Pedicled buccal fat pad was used as an interpositioning material to cover the raw areas in the oral cavity after incision and release of fibrous bands. Results. In 8 patients, the range of pre operative mouth opening was 3–18 mm (mean 14 mm. As the result of the successful surgical procedure, the size of the intra operative mouth opening was ranged from 25–38 mm (mean 33.25 mm. The patients were discharged 5–7 days after the operation. The range of the mouth opening at this time was 25–36 mm (mean 30.63 mm. The results were evaluated using student’s t test and found to be statistically significant. The pedicled grafts took up uneventfull.

  15. Adhesive small bowel obstruction: predictive value of oral contrast administration on the need for surgery Obstrucción intestinal adherencial: valor predictivo de la administración precoz de contraste radiológico sobre la necesidad de cirugía

    Directory of Open Access Journals (Sweden)

    J Perea García

    2004-03-01

    Full Text Available Introduction: adhesive small bowel obstruction (SBO is a common cause of hospital admission. Nonoperative management is initially recommended unless there is suspicion of strangulation, but its optimal duration is controversial. The aims of our study was to evaluate the usefulness of radiographic small bowel examination with contrast medium to predict the need for surgery in SBO. Material and methods: this prospective study carried out from January 1999 to December 2001, included 100 patients with clinical and radiological criteria of adhesive SBO. We described the past medical history, as well as clinical picture, blood tests and radiological findings in these patients. Fifty cubic centimeters of 5% barium suspension were given orally, and plain abdominal radiographs were taken at 4, 8, 16, and 24 hours afterwards. A liquid diet was given as soon as the contrast medium appeared in the right colon. Otherwise, surgical intervention was considered based on the outcome of the patient and the criteria of the emergency surgical team. Results: in 70 patients, barium contrast appeared in the right colon, and a liquid diet was tolerated by 69 of them (98.6%. Mean hospitalization time for this group was 43 ± 17 hours. In the remaining 30 patients, no evidence of barium contrast in the right colon was seen, and 25 of them underwent surgery (75%, while the other 5 tolerated a liquid diet. Mean hospitalization time for this second group of patients was 13.8 ± 11 days. Sensitivity, specificity, positive predictive value, and negative predictive value for the absence of contrast medium in the right colon within 24 hours as a predictor of surgery were 93, 96, 98 and 83%, respectively. There was a statistical significant relationship (p Introducción: la obstrucción intestinal adherencial (OIA es una importante causa de ingreso hospitalario. Salvo que exista sospecha de estrangulación, está indicado inicialmente el manejo conservador. No obstante, el

  16. Comparison of mounting methods for the evaluation of fibers by phase contrast microscopy.

    Science.gov (United States)

    Lee, Eun Gyung; Pang, Thomas W S; Nelson, John; Andrew, Mike; Harper, Martin

    2011-07-01

    The objectives of this study were to evaluate mounting methods for fiber examination of air sample filters by phase contrast microscopy (PCM) and to evaluate differences in fiber counts that might be due to fiber movement. Acetone/triacetin (AT) with various amounts of triacetin and acetone/Euparal (AE) where the mounting medium was placed between the cleared filter wedge and the coverslip were tested as a function of time. Field sample slides collected from a taconite iron-ore processing mill, a tremolitic talc-ore processing mill, and from around a crusher in a meta-basalt stone quarry were prepared with relocatable coverslips to revisit the same field areas on the slides. For each slide, three or four field areas were randomly selected and pictures were taken every 2 weeks to determine any sign of fiber movement over time. For 11 AT slides (named as AT-3.5) prepared with 3.5 μl of the mounting medium according to the NIOSH 7400 method, no fiber movements were detected over 59 weeks. On the other hand, AT slides prepared with larger quantities (10, 15, and 20 μl) of the mounting medium (named as AT-10) and AE slides prepared with ∼10 μl mounting medium showed fiber movement from the eighth day at the earliest. Fiber movement began earlier for the slides mounted with excess triacetin than for those mounted with Euparal. The sample slide storage method, either vertically or horizontally, did not seem to accelerate fiber movement. Additionally, two other modified methods, dimethylformamide solution/Euparal (mDE) and dimethylformamide solution/triacetin (mDT), were also prepared where the mounting medium was placed between the cleared filter wedge and the glass slide. The findings of fiber movements were similar; when 3.5 μl of triacetin was used for the mDT slides, fiber movements were not detected, while fibers on slides prepared with 10 μl triacetin (mDT-10) moved around. No fiber movements were observed for the mDE slides at any time during 59 weeks. Once

  17. Recurrent balanoposthitis of mixed etiology: relation to oral sex and selection of an efficient treatment method

    Directory of Open Access Journals (Sweden)

    O. B. Demianova

    2014-01-01

    Full Text Available Goal. To study the dependence between the recurrent balanoposthitis of mixed etiology and oral sex. To assess the efficacy, tolerance and cosmetic acceptability of a combination topical drug on the basis of a cream for the treatment of balanoposthitis of Candida and bacterial etiology. Materials and methods. An open-label single-arm non-randomized study involved 48 men aged 22-43 suffering from recurrent balanoposthitis of mixed etiology and their long-term sex partners. All of the subjects underwent the following tests: complete blood count, clinical urine test, blood biochemistry (AST, ALT, total bilirubin, thymol test and blood glucose, MRSA, blood tests for anti-hepatitis B and C virus antibodies, HIV-1/-2 antibody screening test, microscopy of urethral, vaginal and cervical canal materials, PCR for Chlamydia trachomatis, Trichomonas vaginalis, N. gonorrhoeae, Mycoplasma genitalium, Ureaplasma spp, bacterial swab tests based on urethral materials (in men, vaginal materials (in women and throat (in subjects of both sexes, and microscopy of tongue scrapings. 46 male patients used the Candiderm cream (Glenmark Pharmaceuticals Ltd. for 10-14 days. Physicians assessed the efficacy based on the symptom intensity and patient’s opinion. Results. In people who practiced unprotected oral sex, a high contamination of mucous coats in the oral cavity, throat and genitals with yeast fungi and opportunistic bacteria was revealed. C. Аlbicans was often found in diagnostically significant amounts in couples. The authors substantiate the possibility of a contact-type transmission of opportunistic bacteria during oral sex resulting in balanoposthitis of mixed Candida and bacterial etiology or exacerbation of their condition after sexual contacts in men practicing unprotected oral sex. Evident clinical efficacy and safety of the combination as well as good tolerance and convenience of application of the combination topical drug comprising beclomethasone

  18. Usefulness of 3D-VIBE method in breast dynamic MRI. Imaging parameters and contrasting effects

    International Nuclear Information System (INIS)

    Uchikoshi, Masato; Ueda, Takashi; Nishiki, Shigeo; Satou, Kouichi; Wada, Akihiko; Imaoka, Izumi; Matsuo, Michimasa

    2003-01-01

    MR imaging (MRI) has been reported to be a useful modality to characterize breast tumors and to evaluate disease extent. Contrast-enhanced dynamic MRI, in particular, allows breast lesions to be characterized with high sensitivity and specificity. Our study was designed to develop three-dimensional volumetric interpolated breath-hold examination (3D-VIBE) techniques for the evaluation of breast tumors. First, agarose/Gd-DTPA phantoms with various concentrations of Gd-DTPA were imaged using 3D-VIBE and turbo spin echo (TSE). Second, one of the phantoms was imaged with 3D-VIBE using different flip angles. Finally, water excitation (WE) and a chemical shift-selective (CHESS) pulse were applied to the images. Each image was analyzed for signal intensity, signal-to-noise ratio (1.25*Ms/Mb) (SNR), and contrast ratio [(Ms1-Ms2)/{(Ms1+Ms2)/2}]. The results showed that 3D-VIBE provided better contrast ratios with a linear fit than TSE, although 3D-VIBE showed a lower SNR. To reach the best contrast ratio, the optimized flip angle was found to be 30 deg for contrast-enhanced dynamic study. Both WE and CHESS pulses were reliable for obtaining fat- suppressed images. In conclusion, the 3D-VIBE technique can image the entire breast area with high resolution and provide better contrast than TSE. Our phantom study suggests that optimized 3D-VIBE may be useful for the assessment of breast tumors. (author)

  19. Analysis of x-ray reflectivity data from low-contrast polymer bilayer systems using a Fourier method

    International Nuclear Information System (INIS)

    Seeck, O. H.; Kaendler, I. D.; Tolan, M.; Shin, K.; Rafailovich, M. H.; Sokolov, J.; Kolb, R.

    2000-01-01

    X-ray reflectivity data of polymer bilayer systems have been analyzed using a Fourier method which takes into account different limits of integration in q-space. It is demonstrated that the interfacial parameters can be determined with high accuracy although the difference in the electron density (the contrast) of the two polymers is extremely small. This method is not restricted to soft-matter thin films. It can be applied to any reflectivity data from low-contrast layer systems. (c) 2000 American Institute of Physics

  20. A Comparison of Case Study and Traditional Teaching Methods for Improvement of Oral Communication and Critical-Thinking Skills

    Science.gov (United States)

    Noblitt, Lynnette; Vance, Diane E.; Smith, Michelle L. DePoy

    2010-01-01

    This study compares a traditional paper presentation approach and a case study method for the development and improvement of oral communication skills and critical-thinking skills in a class of junior forensic science majors. A rubric for rating performance in these skills was designed on the basis of the oral communication competencies developed…

  1. A dielectrophoretic method of discrimination between normal oral epithelium, and oral and oropharyngeal cancer in a clinical setting.

    Science.gov (United States)

    Graham, K A; Mulhall, H J; Labeed, F H; Lewis, M P; Hoettges, K F; Kalavrezos, N; McCaul, J; Liew, C; Porter, S; Fedele, S; Hughes, M P

    2015-08-07

    Despite the accessibility of the oral cavity to clinical examination, delays in diagnosis of oral and oropharyngeal carcinoma (OOPC) are observed in a large majority of patients, with negative impact on prognosis. Diagnostic aids might help detection and improve early diagnosis, but there remains little robust evidence supporting the use of any particular diagnostic technology at the moment. The aim of the present feasibility first-in-human study was to evaluate the preliminary diagnostic validity of a novel technology platform based on dielectrophoresis (DEP). DEP does not require labeling with antibodies or stains and it is an ideal tool for rapid analysis of cell properties. Cells from OOPC/dysplasia tissue and healthy oral mucosa were collected from 57 study participants via minimally-invasive brush biopsies and tested with a prototype DEP platform using median membrane midpoint frequency as main analysis parameter. Results indicate that the current DEP platform can discriminate between brush biopsy samples from cancerous and healthy oral tissue with a diagnostic sensitivity of 81.6% and a specificity of 81.0%. The present ex vivo results support the potential application of DEP testing for identification of OOPC. This result indicates that DEP has the potential to be developed into a low-cost, rapid platform as an assistive tool for the early identification of oral cancer in primary care; given the rapid, minimally-invasive and non-expensive nature of the test, dielectric characterization represents a promising platform for cost-effective early cancer detection.

  2. The pointillism method for creating stimuli suitable for use in computer-based visual contrast sensitivity testing.

    Science.gov (United States)

    Turner, Travis H

    2005-03-30

    An increasingly large corpus of clinical and experimental neuropsychological research has demonstrated the utility of measuring visual contrast sensitivity. Unfortunately, existing means of measuring contrast sensitivity can be prohibitively expensive, difficult to standardize, or lack reliability. Additionally, most existing tests do not allow full control over important characteristics, such as off-angle rotations, waveform, contrast, and spatial frequency. Ideally, researchers could manipulate characteristics and display stimuli in a computerized task designed to meet experimental needs. Thus far, 256-bit color limitation in standard cathode ray tube (CRT) monitors has been preclusive. To this end, the pointillism method (PM) was developed. Using MATLAB software, stimuli are created based on both mathematical and stochastic components, such that differences in regional luminance values of the gradient field closely approximate the desired contrast. This paper describes the method and examines its performance in sine and square-wave image sets from a range of contrast values. Results suggest the utility of the method for most experimental applications. Weaknesses in the current version, the need for validation and reliability studies, and considerations regarding applications are discussed. Syntax for the program is provided in an appendix, and a version of the program independent of MATLAB is available from the author.

  3. Method for the preparation of new X-ray contrast media

    International Nuclear Information System (INIS)

    1977-01-01

    The chemical preparation is described of contrast media possessing an optimal combination of the following parameters: non-toxicity, non-ionogenicity, osmolality, viscosity, stability, ease and cheapness of preparation. Triiodinated and substituted isophtalamides are used with hydroxyethyl or hydroxypropyl groups as substituents. The result is an aqueous solution of isomers, from which the meso-isomer was removed by crystallization

  4. Comparison of RNA Extraction Methods for Molecular Analysis of Oral Cytology

    Directory of Open Access Journals (Sweden)

    Mônica Ghislaine Oliveira Alves

    2016-01-01

    Full Text Available Objective of work: The aim of this study was to compare three methods of RNA extraction for molecular analysis of oral cytology to establish the best technique, considering its concentration and purity for molecular tests of oral lesions such as real-time reverse transcriptase reaction. Material and methods: The sample included exfoliative cytology from the oral cavity mucosa of patients with no visible clinical changes, using Orcellex Rovers Brush®. The extraction of total RNA was performed using the following three techniques: 30 samples were extracted by Trizol® technique, 30 by the DirectzolTM RNA Miniprep system and 30 by the RNeasy mini Kit. The absorbance was measured by spectrophotometer to estimate the purity. The estimated RNA concentration was obtained by multiplying the value of A260 (ng/mL by 40. Statistical analysis of the obtained data was performed using GraphPad Prism 5.03 software with Student t, analysis of variance and Bonferroni tests, considering p ≤0.05. Results: Trizol® group revealed higher average concentration, followed by Direct-zolTM and Rneasy group. It was observed that the RNA Direct-zolTM group had the highest purity, followed by RNeasy and Trizol® groups, allowing for the two ratios. Conclusion: Considering all aspects, concentration, purity and time spent in the procedures, the Direct-zolTM group showed the best results.

  5. Perceptions of Teaching Methods for Preclinical Oral Surgery: A Comparison with Learning Styles

    Science.gov (United States)

    Omar, Esam

    2017-01-01

    Purpose: Dental extraction is a routine part of clinical dental practice. For this reason, understanding the way how students’ extraction knowledge and skills development are important. Problem Statement and Objectives: To date, there is no accredited statement about the most effective method for the teaching of exodontia to dental students. Students have different abilities and preferences regarding how they learn and process information. This is defined as learning style. In this study, the effectiveness of active learning in the teaching of preclinical oral surgery was examined. The personality type of the groups involved in this study was determined, and the possible effect of personality type on learning style was investigated. Method: This study was undertaken over five years from 2011 to 2015. The sample consisted of 115 students and eight staff members. Questionnaires were submitted by 68 students and all eight staff members involved. Three measures were used in the study: The Index of Learning Styles (Felder and Soloman, 1991), the Myers-Briggs Type Indicator (MBTI), and the styles of learning typology (Grasha and Hruska-Riechmann). Results and Discussion: Findings indicated that demonstration and minimal clinical exposure give students personal validation. Frequent feedback on their work is strongly indicated to build the cognitive, psychomotor, and interpersonal skills needed from preclinical oral surgery courses. Conclusion: Small group cooperative active learning in the form of demonstration and minimal clinical exposure that gives frequent feedback and students’ personal validation on their work is strongly indicated to build the skills needed for preclinical oral surgery courses. PMID:28357004

  6. Comparison of oral fluid collection methods for the molecular detection of hepatitis B virus.

    Science.gov (United States)

    Portilho, M M; Mendonça, Acf; Marques, V A; Nabuco, L C; Villela-Nogueira, C A; Ivantes, Cap; Lewis-Ximenez, L L; Lampe, E; Villar, L M

    2017-11-01

    This study aims to compare the efficiency of four oral fluid collection methods (Salivette, FTA Card, spitting and DNA-Sal) to detect HBV DNA by qualitative PCR. Seventy-four individuals (32 HBV reactive and 42 with no HBV markers) donated serum and oral fluid. In-house qualitative PCR to detect HBV was used for both samples and commercial quantitative PCR for serum. HBV DNA was detected in all serum samples from HBV-infected individuals, and it was not detected in control group. HBV DNA from HBV group was detected in 17 samples collected with Salivette device, 16 samples collected by FTA Card device, 16 samples collected from spitting and 13 samples collected by DNA-Sal device. Samples that corresponded to a higher viral load in their paired serum sample could be detected using all oral fluid collection methods, but Salivette collection device yielded the largest numbers of positive samples and had a wide range of viral load that was detected. It was possible to detect HBV DNA using all devices tested, but higher number of positive samples was observed when samples were collected using Salivette device, which shows high concordance to viral load observed in the paired serum samples. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.

  7. A method for fast determination of psoralens in oral solutions of phytomedicines using liquid chromatography.

    Science.gov (United States)

    Pires, Adriana Elias; Honda, Neli Kiko; Cardoso, Cláudia Andréa Lima

    2004-10-29

    A method for sample preparation and analysis by high performance liquid chromatography with UV detection (HPLC-UV) has been developed for routine analysis of psoralen and bergapten, photosensitizing compounds, in oral solutions of phytomedicines employed in Brazil for some illnesses. The linearity, accuracy, the inter- and intra-day precision of the procedure were evaluated. Calibration curves for psoralen and bergapten were linear in the range of 1.0-600.0 microg ml(-1) and 1.0-400.0 microg ml(-1) respectively. The recoveries of the psoralens in the oral solutions analysed were 94.43-99.97%. The percentage coefficient of variation (CV) of the quantitative analysis of the psoralens in the products analysis was within 5%. In inter-equipment study was employed gas chromatography-flame ionization (CG-FID) detection.

  8. Portfolio: a comprehensive method of assessment for postgraduates in oral and maxillofacial surgery.

    Science.gov (United States)

    Kadagad, Poornima; Kotrashetti, S M

    2013-03-01

    Post graduate learning and assessment is an important responsibility of an academic oral and maxillofacial surgeon. The current method of assessment for post graduate training include formative evaluation in the form of seminars, case presentations, log books and infrequently conducted end of year theory exams. End of the course theory and practical examination is a summative evaluation which awards the degree to the student based on grades obtained. Oral and maxillofacial surgery is mainly a skill based specialty and deliberate practice enhances skill. But the traditional system of assessment of post graduates emphasizes their performance on the summative exam which fails to evaluate the integral picture of the student throughout the course. Emphasis on competency and holistic growth of the post graduate student during training in recent years has lead to research and evaluation of assessment methods to quantify students' progress during training. Portfolio method of assessment has been proposed as a potentially functional method for post graduate evaluation. It is defined as a collection of papers and other forms of evidence that learning has taken place. It allows the collation and integration of evidence on competence and performance from different sources to gain a comprehensive picture of everyday practice. The benefits of portfolio assessment in health professions education are twofold: it's potential to assess performance and its potential to assess outcomes, such as attitudes and professionalism that are difficult to assess using traditional instruments. This paper is an endeavor for the development of portfolio method of assessment for post graduate student in oral and maxillofacial surgery.

  9. A method to implement the reservoir-wave hypothesis using phase-contrast magnetic resonance imaging

    OpenAIRE

    Gray, Robert D.M.; Parker, Kim H.; Quail, Michael A.; Taylor, Andrew M.; Biglino, Giovanni

    2016-01-01

    The reservoir-wave hypothesis states that the blood pressure waveform can be usefully divided into a “reservoir pressure” related to the global compliance and resistance of the arterial system, and an “excess pressure” that depends on local conditions. The formulation of the reservoir-wave hypothesis applied to the area waveform is shown, and the analysis is applied to area and velocity data from high-resolution phase-contrast cardiovascular magnetic resonance (CMR) imaging. A validation stud...

  10. An Efficient Method for Detection of Outliers in Tracer Curves Derived from Dynamic Contrast-Enhanced Imaging

    Directory of Open Access Journals (Sweden)

    Linning Ye

    2018-01-01

    Full Text Available Presence of outliers in tracer concentration-time curves derived from dynamic contrast-enhanced imaging can adversely affect the analysis of the tracer curves by model-fitting. A computationally efficient method for detecting outliers in tracer concentration-time curves is presented in this study. The proposed method is based on a piecewise linear model and implemented using a robust clustering algorithm. The method is noniterative and all the parameters are automatically estimated. To compare the proposed method with existing Gaussian model based and robust regression-based methods, simulation studies were performed by simulating tracer concentration-time curves using the generalized Tofts model and kinetic parameters derived from different tissue types. Results show that the proposed method and the robust regression-based method achieve better detection performance than the Gaussian model based method. Compared with the robust regression-based method, the proposed method can achieve similar detection performance with much faster computation speed.

  11. A new method for information retrieval in two-dimensional grating-based X-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wang Zhi-Li; Gao Kun; Chen Jian; Ge Xin; Tian Yang-Chao; Wu Zi-Yu; Zhu Pei-Ping

    2012-01-01

    Grating-based X-ray phase contrast imaging has been demonstrated to be an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refraction directions. Recently, we have developed a novel reverse-projection (RP) method, which is capable of retrieving the object information efficiently with one-dimensional (1D) grating-based phase contrast imaging. In this contribution, we present its extension to the 2D grating-based X-ray phase contrast imaging, named the two-dimensional reverse-projection (2D-RP) method, for information retrieval. The method takes into account the nonlinear contributions of two refraction directions and allows the retrieval of the absorption, the horizontal and the vertical refraction images. The obtained information can be used for the reconstruction of the three-dimensional phase gradient field, and for an improved phase map retrieval and reconstruction. Numerical experiments are carried out, and the results confirm the validity of the 2D-RP method

  12. Real-time contrast imaging: a new method to monitor capillary recruitment in human forearm skeletal muscle.

    NARCIS (Netherlands)

    Mulder, A.H.; Dijk, A.P.J. van; Smits, P.; Tack, C.J.J.

    2008-01-01

    OBJECTIVE: Muscle capillary perfusion can be measured by contrast-enhanced ultrasound. We examined whether a less time-consuming ultrasound technique, called "real-time imaging," could be used to measure capillary recruitment in human forearm skeletal muscle. METHODS: We measured microvascular blood

  13. Imaging transplanted stem cells in real time using an MRI dual-contrast method

    Science.gov (United States)

    Ngen, Ethel J.; Wang, Lee; Kato, Yoshinori; Krishnamachary, Balaji; Zhu, Wenlian; Gandhi, Nishant; Smith, Barbara; Armour, Michael; Wong, John; Gabrielson, Kathleen; Artemov, Dmitri

    2015-01-01

    Stem cell therapies are currently being investigated for the repair of brain injuries. Although exogenous stem cell labelling with superparamagnetic iron oxide nanoparticles (SPIONs) prior to transplantation provides a means to noninvasively monitor stem cell transplantation by magnetic resonance imaging (MRI), monitoring cell death is still a challenge. Here, we investigate the feasibility of using an MRI dual-contrast technique to detect cell delivery, cell migration and cell death after stem cell transplantation. Human mesenchymal stem cells were dual labelled with SPIONs and gadolinium-based chelates (GdDTPA). The viability, proliferation rate, and differentiation potential of the labelled cells were then evaluated. The feasibility of this MRI technique to distinguish between live and dead cells was next evaluated using MRI phantoms, and in vivo using both immune-competent and immune-deficient mice, following the induction of brain injury in the mice. All results were validated with bioluminescence imaging. In live cells, a negative (T2/T2*) MRI contrast predominates, and is used to track cell delivery and cell migration. Upon cell death, a diffused positive (T1) MRI contrast is generated in the vicinity of the dead cells, and serves as an imaging marker for cell death. Ultimately, this technique could be used to manage stem cell therapies. PMID:26330231

  14. Knowledge of users of low-dose oral combined contraceptives about the method

    Directory of Open Access Journals (Sweden)

    Camila Félix Américo

    2013-07-01

    Full Text Available OBJECTIVES: to identify the knowledge of users of combined oral contraceptive about correct use, side effects and complications; to verify the correlation between knowledge about the method with age, education, family income and time of use. METHOD: cross-sectional study performed in Fortaleza, Ceará, Brazil, from March to July 2010, with 294 women. Data were collected through interviews. RESULTS: 75% had substantial knowledge about the proper use and side effects and no knowledge about complications. The higher the educational level and family income, the higher the women's knowledge about the correct use of the method. Positive correlation suggests that women who used the method for longer knew more about its side effects. CONCLUSION: there are knowledge gaps about the method, which are influenced by socioeconomic variables and use time.

  15. Dental plaque as a biofilm - a risk in oral cavity and methods to prevent

    Directory of Open Access Journals (Sweden)

    Renata Chałas

    2015-10-01

    Full Text Available Bacteria living constantly in the oral cavity are in the form of a biofilm. The biofilm formed on a solid base such as the enamel of the teeth, fillings, restorations, orthodontic appliances or obturators is dental plaque. Disturbance of homeostasis of biofilm, excessive growth or increase in the number of acid-forming bacteria leads to the development of the most common diseases of the oral cavity, i.e. dental caries and periodontal disease. The presence of bacterial biofilm on the walls of the root canal or at the top of the root on an outer wall leads to complications and failure in endodontic treatment. The aim of the study was to present the latest information on the occurrence, development and the role of biofilm in the etiopathogenesis of oral diseases and its control. Based on the literature analyzed, it can be concluded that the biofilm, due to its complex structure and numerous mechanisms of bacteria adaptation, is an effective barrier against the traditional agents with antibacterial properties. There are now great hopes for nanotechnology as an innovative method for obtaining new structures of nanometric size and different properties than source materials. The use of antibacterial properties of nano-silver used in dentistry significantly reduces the metabolic activity and the number of colony forming bacteria and lactic acid production in the biofilm.

  16. [Dental plaque as a biofilm - a risk in oral cavity and methods to prevent].

    Science.gov (United States)

    Chałas, Renata; Wójcik-Chęcińska, Ilona; Woźniak, Michał J; Grzonka, Justyna; Święszkowski, Wojciech; Kurzydłowski, Krzysztof J

    2015-10-13

    Bacteria living constantly in the oral cavity are in the form of a biofilm. The biofilm formed on a solid base such as the enamel of the teeth, fillings, restorations, orthodontic appliances or obturators is dental plaque. Disturbance of homeostasis of biofilm, excessive growth or increase in the number of acid-forming bacteria leads to the development of the most common diseases of the oral cavity, i.e. dental caries and periodontal disease. The presence of bacterial biofilm on the walls of the root canal or at the top of the root on an outer wall leads to complications and failure in endodontic treatment. The aim of the study was to present the latest information on the occurrence, development and the role of biofilm in the etiopathogenesis of oral diseases and its control. Based on the literature analyzed, it can be concluded that the biofilm, due to its complex structure and numerous mechanisms of bacteria adaptation, is an effective barrier against the traditional agents with antibacterial properties. There are now great hopes for nanotechnology as an innovative method for obtaining new structures of nanometric size and different properties than source materials. The use of antibacterial properties of nano-silver used in dentistry significantly reduces the metabolic activity and the number of colony forming bacteria and lactic acid production in the biofilm.

  17. Perceptions of Teaching Methods for Preclinical Oral Surgery: A Comparison with Learning Styles.

    Science.gov (United States)

    Omar, Esam

    2017-01-01

    Dental extraction is a routine part of clinical dental practice. For this reason, understanding the way how students' extraction knowledge and skills development are important. To date, there is no accredited statement about the most effective method for the teaching of exodontia to dental students. Students have different abilities and preferences regarding how they learn and process information. This is defined as learning style. In this study, the effectiveness of active learning in the teaching of preclinical oral surgery was examined. The personality type of the groups involved in this study was determined, and the possible effect of personality type on learning style was investigated. This study was undertaken over five years from 2011 to 2015. The sample consisted of 115 students and eight staff members. Questionnaires were submitted by 68 students and all eight staff members involved. Three measures were used in the study: The Index of Learning Styles (Felder and Soloman, 1991), the Myers-Briggs Type Indicator (MBTI), and the styles of learning typology (Grasha and Hruska-Riechmann). Findings indicated that demonstration and minimal clinical exposure give students personal validation. Frequent feedback on their work is strongly indicated to build the cognitive, psychomotor, and interpersonal skills needed from preclinical oral surgery courses. Small group cooperative active learning in the form of demonstration and minimal clinical exposure that gives frequent feedback and students' personal validation on their work is strongly indicated to build the skills needed for preclinical oral surgery courses.

  18. Abdominal ultrasound-scanning versus non-contrast computed tomography as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Liisberg, Mads; Diederichsen, Axel C.; Lindholt, Jes S.

    2017-01-01

    Background: Validating non-contrast-enhanced computed tomography (nCT) compared to ultrasound sonography (US) as screening method for abdominal aortic aneurysm (AAA) screening. Methods: Consecutively attending men (n = 566) from the pilot study of the randomized Danish CardioVascular Screening......CT seems superior to US concerning sensitivity, and is able to detect aneurysmal lesions not detectable with US. Finally, the prevalence of AAA in Denmark seems to remain relatively high, in this small pilot study group....

  19. Modified Right Heart Contrast Echocardiography Versus Traditional Method in Diagnosis of Right-to-Left Shunt: A Comparative Study

    OpenAIRE

    Wang, Yi; Zeng, Jie; Yin, Lixue; Zhang, Mei; Hou, Dailun

    2016-01-01

    BACKGROUND: The purpose of this study was to evaluate the reliability, effectiveness, and safety of modified right heart contrast transthoracic echocardiography (cTTE) in comparison with the traditional method. MATERIAL AND METHODS: We performed a modified right heart cTTE using saline mixed with a small sample of patient's own blood. Samples were agitated with varying intensity. This study protocol involved microscopic analysis and patient evaluation. 1. Microscopic analysis: After two contr...

  20. Evaluation of Different Methods for Removing Oral Biofilm in Patients Admitted to the Intensive Care Unit

    Science.gov (United States)

    Oliveira, Maria Sonia; Borges, Alvaro Henrique; Mattos, Fernanda Zanol; Semenoff, Tereza Aparecida Della Vedove; Segundo, Alex Semenoff; Tonetto, Mateus Rodrigues; Bandeca, Matheus Coêlho; Porto, Alessandra Nogueira

    2014-01-01

    Background: The present study aimed to evaluate the different methods for removing oral biofilm in combination with 0.12% chlorhexidine, in patients admitted to the intensive care unit (ICU) of the General University Hospital. Materials and Methods: Initially, the patients were included in the study and underwent periodontal evaluation by means of the visible plaque index (VPI) and gingival bleeding index (GBI). The removal of visible biofilm, by a professional, was carried out using a toothbrush and dental floss, followed by the application of a 0.12% chlorhexidine solution. The patients were included in this randomized and controlled study into four groups (total n = 48), as follows: Chlorhexidine and gauze 12/12 h; chlorhexidine and gauze 24/24 h; chlorhexidine and brushing 12/12 h; chlorhexidine and brushing 24/24 h. The patients underwent the biofilm removal protocol for 7 days and then were subjected to a new clinical evaluation as to VPI and GBI. Data analysis was performed through stratification and arrangement of the records, in order to carry out the associations with health indicators used in the study, and the statistical tests used were Kappa and t-test for independent and paired samples. Results: A decrease in the VPI and GBI values when comparing baseline to the final evaluation for all groups was observed. Conclusion: Based on the methodology, it was possible to concluded that chlorhexidine associated with the mechanical action of the toothbrush or gauze in the times 12 h and 24 h in the ICU environment presented the same results as regards amount of visible biofilm. How to cite the article: Oliveira MS, Borges AH, Mattos FZ, Semenoff TA, Segundo AS, Tonetto MR, Bandeca MC, Porto AN. Evaluation of different methods for removing oral biofilm in patients admitted to the intensive care unit. J Int Oral Health 2014;6(3):61-4. PMID:25083034

  1. Technical Note: Measuring contrast- and noise-dependent spatial resolution of an iterative reconstruction method in CT using ensemble averaging

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Lifeng, E-mail: yu.lifeng@mayo.edu; Vrieze, Thomas J.; Leng, Shuai; Fletcher, Joel G.; McCollough, Cynthia H. [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2015-05-15

    Purpose: The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of this study was to measure the spatial resolution of a commercially available IR method using ensemble-averaged images acquired from repeated scans. Methods: A low-contrast phantom containing three rods (7, 14, and 21 HU below background) was scanned on a 128-slice CT scanner at three dose levels (CTDI{sub vol} = 16, 8, and 4 mGy). Images were reconstructed using two filtered-backprojection (FBP) kernels (B40 and B20) and a commercial IR method (sinogram affirmed iterative reconstruction, SAFIRE, Siemens Healthcare) with two strength settings (I40-3 and I40-5). The same scan was repeated 100 times at each dose level. The modulation transfer function (MTF) was calculated based on the edge profile measured on the ensemble-averaged images. Results: The spatial resolution of the two FBP kernels, B40 and B20, remained relatively constant across contrast and dose levels. However, the spatial resolution of the two IR kernels degraded relative to FBP as contrast or dose level decreased. For a given dose level at 16 mGy, the MTF{sub 50%} value normalized to the B40 kernel decreased from 98.4% at 21 HU to 88.5% at 7 HU for I40-3 and from 97.6% to 82.1% for I40-5. At 21 HU, the relative MTF{sub 50%} value decreased from 98.4% at 16 mGy to 90.7% at 4 mGy for I40-3 and from 97.6% to 85.6% for I40-5. Conclusions: A simple technique using ensemble averaging from repeated CT scans can be used to measure the spatial resolution of IR techniques in CT at very low contrast levels. The evaluated IR method degraded the spatial resolution at low contrast and high noise levels.

  2. A laboratory measurement method for pressure sensitive adhesives in agglomeration deinking of mixed office waste paper: The high-low scanning contrast method

    OpenAIRE

    Guolin Tong; Shuang Sun; Cuixia Wang; Kecheng Fu; Yungchang F. Chin

    2012-01-01

    A simple measurement method for pressure sensitive adhesives (PSA) in an agglomeration deinking system of mixed office waste paper was studied. This method was based on the different scanning performance of ink and PSA specks in hot-pressed and oven-dried handsheets with the change of contrast values that had been selected and set in the image analysis software. The numbers of ink specks per square meter (NPM) were well recognized at both low and high contrast values and exhibited a very good...

  3. A method to extract quantitative information in analyzer-based x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Pagot, E.; Cloetens, P.; Fiedler, S.; Bravin, A.; Coan, P.; Baruchel, J.; Haertwig, J.; Thomlinson, W.

    2003-01-01

    Analyzer-based imaging is a powerful phase-sensitive technique that generates improved contrast compared to standard absorption radiography. Combining numerically two images taken on either side at ±1/2 of the full width at half-maximum (FWHM) of the rocking curve provides images of 'pure refraction' and of 'apparent absorption'. In this study, a similar approach is made by combining symmetrical images with respect to the peak of the analyzer rocking curve but at general positions, ±α·FWHM. These two approaches do not consider the ultrasmall angle scattering produced by the object independently, which can lead to inconsistent results. An accurate way to separately retrieve the quantitative information intrinsic to the object is proposed. It is based on a statistical analysis of the local rocking curve, and allows one to overcome the problems encountered using the previous approaches

  4. Dual-energy approach to contrast-enhanced mammography using the balanced filter method: spectral optimization and preliminary phantom measurement.

    Science.gov (United States)

    Saito, Masatoshi

    2007-11-01

    Dual-energy contrast agent-enhanced mammography is a technique of demonstrating breast cancers obscured by a cluttered background resulting from the contrast between soft tissues in the breast. The technique has usually been implemented by exploiting two exposures to different x-ray tube voltages. In this article, another dual-energy approach using the balanced filter method without switching the tube voltages is described. For the spectral optimization of dual-energy mammography using the balanced filters, we applied a theoretical framework reported by Lemacks et al. [Med. Phys. 29, 1739-1751 (2002)] to calculate the signal-to-noise ratio (SNR) in an iodinated contrast agent subtraction image. This permits the selection of beam parameters such as tube voltage and balanced filter material, and the optimization of the latter's thickness with respect to some critical quantity-in this case, mean glandular dose. For an imaging system with a 0.1 mm thick CsI:T1 scintillator, we predict that the optimal tube voltage would be 45 kVp for a tungsten anode using zirconium, iodine, and neodymium balanced filters. A mean glandular dose of 1.0 mGy is required to obtain an SNR of 5 in order to detect 1.0 mg/cm2 iodine in the resulting clutter-free image of a 5 cm thick breast composed of 50% adipose and 50% glandular tissue. In addition to spectral optimization, we carried out phantom measurements to demonstrate the present dual-energy approach for obtaining a clutter-free image, which preferentially shows iodine, of a breast phantom comprising three major components-acrylic spheres, olive oil, and an iodinated contrast agent. The detection of iodine details on the cluttered background originating from the contrast between acrylic spheres and olive oil is analogous to the task of distinguishing contrast agents in a mixture of glandular and adipose tissues.

  5. Dual-energy approach to contrast-enhanced mammography using the balanced filter method: Spectral optimization and preliminary phantom measurement

    International Nuclear Information System (INIS)

    Saito, Masatoshi

    2007-01-01

    Dual-energy contrast agent-enhanced mammography is a technique of demonstrating breast cancers obscured by a cluttered background resulting from the contrast between soft tissues in the breast. The technique has usually been implemented by exploiting two exposures to different x-ray tube voltages. In this article, another dual-energy approach using the balanced filter method without switching the tube voltages is described. For the spectral optimization of dual-energy mammography using the balanced filters, we applied a theoretical framework reported by Lemacks et al. [Med. Phys. 29, 1739-1751 (2002)] to calculate the signal-to-noise ratio (SNR) in an iodinated contrast agent subtraction image. This permits the selection of beam parameters such as tube voltage and balanced filter material, and the optimization of the latter's thickness with respect to some critical quantity--in this case, mean glandular dose. For an imaging system with a 0.1 mm thick CsI:Tl scintillator, we predict that the optimal tube voltage would be 45 kVp for a tungsten anode using zirconium, iodine, and neodymium balanced filters. A mean glandular dose of 1.0 mGy is required to obtain an SNR of 5 in order to detect 1.0 mg/cm 2 iodine in the resulting clutter-free image of a 5 cm thick breast composed of 50% adipose and 50% glandular tissue. In addition to spectral optimization, we carried out phantom measurements to demonstrate the present dual-energy approach for obtaining a clutter-free image, which preferentially shows iodine, of a breast phantom comprising three major components - acrylic spheres, olive oil, and an iodinated contrast agent. The detection of iodine details on the cluttered background originating from the contrast between acrylic spheres and olive oil is analogous to the task of distinguishing contrast agents in a mixture of glandular and adipose tissues

  6. Characterization of adaptive statistical iterative reconstruction (ASIR) in low contrast helical abdominal imaging via a transfer function based method

    Science.gov (United States)

    Zhang, Da; Li, Xinhua; Liu, Bob

    2012-03-01

    Since the introduction of ASiR, its potential in noise reduction has been reported in various clinical applications. However, the influence of different scan and reconstruction parameters on the trade off between ASiR's blurring effect and noise reduction in low contrast imaging has not been fully studied. Simple measurements on low contrast images, such as CNR or phantom scores could not explore the nuance nature of this problem. We tackled this topic using a method which compares the performance of ASiR in low contrast helical imaging based on an assumed filter layer on top of the FBP reconstruction. Transfer functions of this filter layer were obtained from the noise power spectra (NPS) of corresponding FBP and ASiR images that share the same scan and reconstruction parameters. 2D transfer functions were calculated as sqrt[NPSASiR(u, v)/NPSFBP(u, v)]. Synthesized ACR phantom images were generated by filtering the FBP images with the transfer functions of specific (FBP, ASiR) pairs, and were compared with the ASiR images. It is shown that the transfer functions could predict the deterministic blurring effect of ASiR on low contrast objects, as well as the degree of noise reductions. Using this method, the influence of dose, scan field of view (SFOV), display field of view (DFOV), ASiR level, and Recon Mode on the behavior of ASiR in low contrast imaging was studied. It was found that ASiR level, dose level, and DFOV play more important roles in determining the behavior of ASiR than the other two parameters.

  7. A simple method to estimate the optimum iodine concentration of contrast material through microcatheters: hydrodynamic calculation with spreadsheet software

    International Nuclear Information System (INIS)

    Yamauchi, Teiyu; Hayashi, Toshihiko; Yamada, Takeshi; Futami, Choichiro; Tsukiyama, Yumiko; Harada, Motoko; Furui, Shigeru; Suzuki, Shigeru; Mimura, Kohshiro

    2008-01-01

    It is important to increase the iodine delivery rate (I), that is the iodine concentration of the contrast material (C) x the flow rate of the contrast material (Q), through microcatheters to obtain arteriograms of the highest contrast. It is known that C is an important factor that influences I. The purpose of this study is to establish a method of hydrodynamic calculation of the optimum iodine concentration (i.e., the iodine concentration at which I becomes maximum) of the contrast material and its flow rate through commercially available microcatheters. Iopamidol, ioversol and iohexol of ten iodine concentrations were used. Iodine delivery rates (I meas) of each contrast material through ten microcatheters were measured. The calculated iodine delivery rate (I cal) and calculated optimum iodine concentration (calculated C opt) were obtained with spreadsheet software. The agreement between I cal and I meas was studied by correlation and logarithmic Bland-Altman analyses. The value of the calculated C opt was within the optimum range of iodine concentrations (i.e. the range of iodine concentrations at which I meas becomes 90% or more of the maximum) in all cases. A good correlation between I cal and I meas (I cal = 1.08 I meas, r = 0.99) was observed. Logarithmic Bland-Altman analysis showed that the 95% confidence interval of I cal/I meas was between 0.82 and 1.29. In conclusion, hydrodynamic calculation with spreadsheet software is an accurate, generally applicable and cost-saving method to estimate the value of the optimum iodine concentration and its flow rate through microcatheters

  8. Short-term effect of two education methods on oral health among hearing impairment children

    Directory of Open Access Journals (Sweden)

    Shiva Pouradeli

    2016-12-01

    CONCLUSION: Both video and dental model effectively improve the oral health of children with HI in short term. Continuous school-based oral health education programs, particularly for HI children, need to be considered.

  9. Multilevel markov chain monte carlo method for high-contrast single-phase flow problems

    KAUST Repository

    Efendiev, Yalchin R.; Jin, Bangti; Michael, Presho; Tan, Xiaosi

    2014-01-01

    Carlo (MLMC) methods. The former provides a hierarchy of approximations of different resolution, whereas the latter gives an efficient way to estimate quantities of interest using samples on different levels. The number of basis functions in the online

  10. Effect of methods of myopia correction on visual acuity, contrast sensitivity, and depth of focus

    NARCIS (Netherlands)

    Nio, YK; Jansonius, NM; Wijdh, RHJ; Beekhuis, WH; Worst, JGF; Noorby, S; Kooijman, AC

    Purpose. To psychophysically measure spherical and irregular aberrations in patients with various types of myopia correction. Setting: Laboratory of Experimental Ophthalmology, University of Groningen, Groningen, The Netherlands. Methods: Three groups of patients with low myopia correction

  11. Establishment and Characterization of Primary Cultures from Iranian Oral Squamous Cell Carcinoma Patients by Enzymatic Method and Explant Culture

    Directory of Open Access Journals (Sweden)

    Meysam Ganjibakhsh

    2017-10-01

    Full Text Available Objectives: Oral Squamous Cell Carcinoma (OSCC is the most frequent oral cancer worldwide. It is known as the eighth most common cancer in men and as the fifth most common cancer in women. Cytogenetic and biochemical studies in recent decades have emphasized the necessity of providing an appropriate tool for such researches. Cancer cell culture is a useful tool for investigations on biochemical, genetic, molecular and immunological characteristics of different cancers, including oral cancer. Here, we explain the establishment process of five primary oral cancer cells derived from an Iranian population.Materials and Methods: The specimens were obtained from five oral cancer patients. Enzymatic, explant culture and magnetic-activated cell sorting (MACS methods were used for cell isolation. After quality control tests, characterization and authentication of primary oral cancer cells were performed by short tandem repeats (STR profiling, chromosome analysis, species identification, and monitoring the growth, morphology and the expression of CD326 and CD133 markers.Results: Five primary oral cancer cells were established from an Iranian population. The flow cytometry results showed that the isolated cells were positive for CD326 and CD133 markers. Furthermore, the cells were free from mycoplasma, bacterial and fungal contamination. No misidentified or cross-contaminated cells were detected by STR analysis.Conclusions: Human primary oral cancer cells provide an extremely useful platform for studying carcinogenesis pathways of oral cancer in Iranian population. They may be helpful in explaining the ethnic differences in cancer biology and the individuality in anticancer drug response in future studies.

  12. Linear information retrieval method in X-ray grating-based phase contrast imaging and its interchangeability with tomographic reconstruction

    Science.gov (United States)

    Wu, Z.; Gao, K.; Wang, Z. L.; Shao, Q. G.; Hu, R. F.; Wei, C. X.; Zan, G. B.; Wali, F.; Luo, R. H.; Zhu, P. P.; Tian, Y. C.

    2017-06-01

    In X-ray grating-based phase contrast imaging, information retrieval is necessary for quantitative research, especially for phase tomography. However, numerous and repetitive processes have to be performed for tomographic reconstruction. In this paper, we report a novel information retrieval method, which enables retrieving phase and absorption information by means of a linear combination of two mutually conjugate images. Thanks to the distributive law of the multiplication as well as the commutative law and associative law of the addition, the information retrieval can be performed after tomographic reconstruction, thus simplifying the information retrieval procedure dramatically. The theoretical model of this method is established in both parallel beam geometry for Talbot interferometer and fan beam geometry for Talbot-Lau interferometer. Numerical experiments are also performed to confirm the feasibility and validity of the proposed method. In addition, we discuss its possibility in cone beam geometry and its advantages compared with other methods. Moreover, this method can also be employed in other differential phase contrast imaging methods, such as diffraction enhanced imaging, non-interferometric imaging, and edge illumination.

  13. Identification of Yeast Species In the Oral Cavity of Iranian Soldiers By Disk Diffusion Method

    Directory of Open Access Journals (Sweden)

    M. Imami

    2008-02-01

    Full Text Available Background:The disk diffusion method for identification of yeasts species was performed based on different but distinct susceptibilities of yeasts spp.to chemicals:janus green, ethidium bromide,2,3,5-triphenyltetrazolium chloride, brilliant green, cycloheximide and rhodamine 6G. Methods: Atotal of 568 Iranian soldiers went under study for isolation and identification of Yeast species from their oral cavity. Asterile swab was used for each individual and specimens were collected from the nasopharynx region, then inoculated to petri dishes containing Sabouraud Dextrose Agar and incubated for 48 hrs at 37 °C. All colonies were counted and stocked in distilled water and stored in a refrigerator for further analysis. The yeasts were identified by the “disk diffusion test” [6,8]. This is a simple, rapid, accurate, and inexpensive technique presented by Sobczak [8]. By this method we identified yeast species within 24-48 hrs. Results: 51.4% of petri dishes were positive for yeast species and 318 strains were identified. Candida albicans, Candida kefyr, Candida tropicalis and Candida guilliermondii were the most common yeast species isolated from the oral cavity of soldiers. Conclusion: We used this method because of its simplicity and other beneficial characteristics for rapid identification of large and numerous isolates and the results were compared with other morphological characters such as chlamydospore and germ tube production. In addition,we used some type strains (Candida parapsilosis: PTCC 5089,Candida tropicalis: PTCC 5028,Saccharomyces cerevisiae:PTCC 5052,Candida lipolytica: PTCC 5063,Candida lipolytica:PTCC 5064,and the results were acceptable.

  14. Determination of blood circulation in oral formations using Rb86 distribution method and labelled micropearl method

    International Nuclear Information System (INIS)

    Fazekas, A.; Posch, E.; Harsing, L.

    1979-01-01

    The blood circulation of incisors, dental pulp and tongue was detemined using the measurement of 86 Rb distribution in rats. The results were compared with those obtained by a simultaneous micropearl method. It was found that 37 per cent of 86 Rb in dental tissues is localized in the hard propiodentium, with a high proportion diffusing from the periodontium. The 86 Rb fraction localized in the tongue represents its blood circulation. (author)

  15. The viability of alternative assessment methods in the Greek upper secondary school: the oral portfolio

    Directory of Open Access Journals (Sweden)

    Angeliki Daphni

    2012-02-01

    Full Text Available Τhe final examination of the English language subject, in the context of the Greek state upper secondary education, is a traditional paper-and-pencil test which does not include any assessment of oracy skills. This article explores the viability of the oral portfolio as an alternative assessment and pedagogic method that can facilitate the assessment of speaking and listening skills and create a more motivating learning environment. To this effect, three methodological tools were designed, namely, a questionnaire addressing upper secondary English teachers in Greek state schools, a case study involving an oral portfolio implementation and finally, a questionnaire for students to record their experience. The study demonstrates that implementation of the portfolio contributed to a successful assessment of oracy skills and that it was a stimulating experience for students. The results of the study also showed that the pedagogical value of the portfolio counterbalanced its practical constraints. The paper concludes by putting forward recommendations for the future application of this assessment technique in state school education.

  16. Method for nuclear magnetic resonance imaging using deuterum as a contrast agent

    Science.gov (United States)

    Kehayias, Joseph J.; Joel, Darrel D.; Adams, William H.; Stein, Harry L.

    1990-01-01

    A method for in vivo NMR imaging of the blood vessels and organs of a patient characterized by using a dark dye-like imaging substance consisting essentially of a stable, high-purity concentration of D.sub.2 O in a solution with water.

  17. A Simplified Method for Upscaling Composite Materials with High Contrast of the Conductivity

    KAUST Repository

    Ewing, R.; Iliev, O.; Lazarov, R.; Rybak, I.; Willems, J.

    2009-01-01

    A large class of industrial composite materials, such as metal foams, fibrous glass materials, mineral wools, and the like, are widely used in insulation and advanced heat exchangers. These materials are characterized by a substantial difference between the thermal properties of the highly conductive materials (glass or metal) and the insulator (air) as well as low volume fractions and complex network-like structures of the highly conductive components. In this paper we address the important issue for the engineering practice of developing fast, reliable, and accurate methods for computing the macroscopic (upscaled) thermal conductivities of such materials. We assume that the materials have constant macroscopic thermal conductivity tensors, which can be obtained by upscaling techniques based on the postprocessing of a number of linearly independent solutions of the steady-state heat equation on representative elementary volumes (REVs). We propose, theoretically justify, and computationally study a numerical method for computing the effective conductivities of materials for which the ratio δ of low and high conductivities satisfies δ ≪ 1. We show that in this case one needs to solve the heat equation in the region occupied by the highly conductive media only. Further, we prove that under certain conditions on the microscale geometry the proposed method gives an approximation that is O(δ)-close to the upscaled conductivity. Finally, we illustrate the accuracy and the limitations of the method on a number of numerical examples. © 2009 Society for Industrial and Applied Mathematics.

  18. Comparing the effects of low-dose contraceptive pills to control dysfunctional uterine bleeding by oral and vaginal methods.

    Science.gov (United States)

    Mehrabian, Ferdous; Abbassi, Fariba

    2013-09-01

    Background and Objective : Contraceptive pills are generally taken orally and can cause side effects such as nausea, vomiting and hypertension. The vaginal use of these pills can reduce such complications. Our objective was to compare the efficacy and side effects of low dose contraceptive pills by oral and vaginal route in the management of dysfunctional uterine bleeding-(DUB) Methods: This comparative observational study was conducted at Beheshti and Alzahra (SA) teaching hospitals, affiliated to Isfahan University of Medical Sciences in 2010-2011. One hundred women who presented with DUB were randomly assigned into two groups of equal number, receiving the low dose oral contraceptive pills by oral or vaginal route for three month. The amount and duration of bleeding were compared at the beginning and at the end of the study and side effects by these two methods compared. The results of this study showed that both oral and vaginal routes effectively reduced the duration and amount of bleeding due to DUB after three courses of treatment. This effect was better in the vaginal method compared with oral administration (P = 0.03). Regarding the side effects, nausea and vomiting were significantly higher in the oral group than in the vaginal group (P = 0.03). Vulvovaginitis infection was more frequent in the vaginal group than in the oral group (P = 0.03). Low dose contraceptive pills are effective in reducing the amount, time, and duration of bleeding in patients with DUB. In addition, reduction of gastrointestinal side effects by vaginal route helps to use these pills by the patient with proper training of physicians, midwives and patients.

  19. Evaluation of high frequency ultrasound methods and contrast agents for characterising tumor response to anti-angiogenic treatment

    Energy Technology Data Exchange (ETDEWEB)

    Rix, Anne, E-mail: arix@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Lederle, Wiltrud, E-mail: wlederle@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Siepmann, Monica, E-mail: monica.siepmann@rub.de [Department of Medical Engineering, Universitätstraße 150, 44780 Bochum, Ruhr-University Bochum, Bochum (Germany); Fokong, Stanley, E-mail: sfokong@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Behrendt, Florian F., E-mail: fbehrendt@ukaachen.de [Department of Nuclear Medicine, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Bzyl, Jessica, E-mail: jbzyl@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Grouls, Christoph, E-mail: cgrouls@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Kiessling, Fabian, E-mail: fkiessling@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Palmowski, Moritz, E-mail: mpalmowski@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Department of Nuclear Medicine, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany)

    2012-10-15

    Purpose: To compare non-enhanced and contrast-enhanced high-frequency 3D Doppler ultrasound with contrast-enhanced 2D and 3D B-mode imaging for assessing tumor vascularity during antiangiogenic treatment using soft-shell and hard-shell microbubbles. Materials and methods: Antiangiogenic therapy effects (SU11248) on vascularity of subcutaneous epidermoid-carcinoma xenografts (A431) in female CD1 nude mice were investigated longitudinally using non-enhanced and contrast-enhanced 3D Doppler at 25 MHz. Additionally, contrast-enhanced 2D and 3D B-mode scans were performed by injecting hard-shell (poly-butyl-cyanoacrylate-based) and soft-shell (phospholipid-based) microbubbles. Suitability of both contrast agents for high frequency imaging and the sensitivity of the different ultrasound methods to assess early antiangiogenic therapy effects were investigated. Ultrasound data were validated by immunohistology. Results: Hard-shell microbubbles induced higher signal intensity changes in tumors than soft-shell microbubbles in 2D B-mode measurements (424 ± 7 vs. 169 ± 8 A.U.; p < 0.01). In 3D measurements, signals of soft-shell microbubbles were hardly above the background (5.48 ± 4.57 vs. 3.86 ± 2.92 A.U.), while signals from hard-shell microbubbles were sufficiently high (30.5 ± 8.06 A.U). Using hard-shell microbubbles 2D and 3D B-mode imaging depicted a significant decrease in tumor vascularity during antiangiogenic therapy from day 1 on. Using soft-shell microbubbles significant therapy effects were observed at day 4 after therapy in 2D B-mode imaging but could not be detected in the 3D mode. With non-enhanced and contrast-enhanced Doppler imaging significant differences between treated and untreated tumors were found from day 2 on. Conclusion: Hard-shell microbubble-enhanced 2D and 3D B-mode ultrasound achieved highest sensitivity for assessing therapy effects on tumor vascularisation and were superior to B-mode ultrasound with soft-shell microbubbles and to Doppler

  20. Application of histogram analysis for the evaluation of vascular permeability in glioma by the K2 parameter obtained with the dynamic susceptibility contrast method: Comparisons with Ktrans obtained with the dynamic contrast enhance method and cerebral blood volume.

    Science.gov (United States)

    Taoka, Toshiaki; Kawai, Hisashi; Nakane, Toshiki; Hori, Saeka; Ochi, Tomoko; Miyasaka, Toshiteru; Sakamoto, Masahiko; Kichikawa, Kimihiko; Naganawa, Shinji

    2016-09-01

    The "K2" value is a factor that represents the vascular permeability of tumors and can be calculated from datasets obtained with the dynamic susceptibility contrast (DSC) method. The purpose of the current study was to correlate K2 with Ktrans, which is a well-established permeability parameter obtained with the dynamic contrast enhance (DCE) method, and determine the usefulness of K2 for glioma grading with histogram analysis. The subjects were 22 glioma patients (Grade II: 5, III: 6, IV: 11) who underwent DSC studies, including eight patients in which both DSC and DCE studies were performed on separate days within 10days. We performed histogram analysis of regions of interest of the tumors and acquired 20th percentile values for leakage-corrected cerebral blood volume (rCBV20%ile), K2 (K220%ile), and for patients who underwent a DCE study, Ktrans (Ktrans20%ile). We evaluated the correlation between K220%ile and Ktrans20%ile and the statistical difference between rCBV20%ile and K220%ile. We found a statistically significant correlation between K220%ile and Ktrans20%ile (r=0.717, pK220%ile showed a statistically significant (pK2 value calculated from the DSC dataset, which can be obtained with a short acquisition time, showed a correlation with Ktrans obtained with the DCE method and may be useful for glioma grading when analyzed with histogram analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. [Application of diversified teaching methods to improve the teaching effects in the course of oral histology and pathology].

    Science.gov (United States)

    Tian, Zhen; Li, Lei; Wang, Li-zhen; Hu, Yu-hua; Zhang, Chun-ye; Li, Jiang

    2016-02-01

    Oral histology and pathology is one of the most important courses in stomatological education which works as a bridge between basic medical courses and clinical courses of oral science. The knowledge of oral histopathology may help the students to correctly understand the histogenesis and development of oral diseases and provide the information for correct treatment and prevention. In order to make the students grasp the necessary basic theories, increase the interest in learning, and improve the teaching effect, we explored a diversified teaching system which included diverse teaching modes, online courses and courseware construction. The application of this system offered the interaction between students and teachers and combination of classes with the internet, and made the boring pathological knowledge be associated with clinical practice. These diversified teaching methods had been used in practice and obtained good teaching results.

  2. Choice of double contrast barium enema (DCBE) method based on patient exposure dose

    Energy Technology Data Exchange (ETDEWEB)

    Bartal, G; Ben Hasid, I [Hillel Yaffe Medical Center, Hadera (Israel)

    1997-11-16

    Morbidity of colon cancer continues to increase, taking second and third places in malignant tumors. The incidence of colorectal cancer (CRC) increases exponentially with age; those over 50 years of age represent 37% of general population, yet account for 95% of the cases, and more than 96% of the deaths from colon malignancies For a long time radiologic examinations were considered as a main pre-operative diagnostic method for cancer of the colon. The sensitivity of the barium enema with regard to diagnosis of the carcinoma and polyps ranges from 92-98.5%. Sigmoidoscopy for detection and removal of polyps has been shown to decrease the incidence of subsequent CRC`s by 70-80% in distal colon. However, the sigmoid colon is often difficult to examine because of associated diverticular disease, and about 15% of tumors in the sigmoid colon are overlooked. (Authors)

  3. Choice of double contrast barium enema (DCBE) method based on patient exposure dose

    International Nuclear Information System (INIS)

    Bartal, G.; Ben Hasid, I.

    1997-01-01

    Morbidity of colon cancer continues to increase, taking second and third places in malignant tumors. The incidence of colorectal cancer (CRC) increases exponentially with age; those over 50 years of age represent 37% of general population, yet account for 95% of the cases, and more than 96% of the deaths from colon malignancies For a long time radiologic examinations were considered as a main pre-operative diagnostic method for cancer of the colon. The sensitivity of the barium enema with regard to diagnosis of the carcinoma and polyps ranges from 92-98.5%. Sigmoidoscopy for detection and removal of polyps has been shown to decrease the incidence of subsequent CRC's by 70-80% in distal colon. However, the sigmoid colon is often difficult to examine because of associated diverticular disease, and about 15% of tumors in the sigmoid colon are overlooked. Authors)

  4. Content analysis of Islamic Republic of Iran television food advertising related to oral health: appeals and performance methods.

    Science.gov (United States)

    Movahhed, Taraneh; Seifi, Safoura; Rashed Mohassel, Anousheh; Dorri, Mojtaba; Khorakian, Fateme; Mohammadzadeh, Zahra

    2014-01-01

    Today, electronic mass media such as television (TV), influence behavioral patterns of their audiences. This study aimed to evaluate what messages on food advertisements related to oral health were transmitted (appeals) and how they were transferred (performance methods & artistic techniques) in Islamic Republic of Iran Broadcasting (IRIB). In this cross sectional study, broadcasted advertisements on 4 important channels of Iran TV were recorded for a week from 8 am to 12 pm in 2012. The content and volume of food advertisements were investigated using a researcher-made check list. Advertisement group (food, non-food), food group (non-cariogenic, cariogenic), advertisement appeals (rational, emotional, and humor content), advertisement performance methods (hard-sell, soft-sell, presenting confirmation of Ministry of Health and Medical Education), and artistic technique were assessed. For variable comparison in groups a chi squared test and t-tests were used via SPSS software. Frequency of food advertisements (14.9%) were less than non-food advertising. Non-cariogenic food advertisements had higher frequency (12.09% (compared to cariogenic food (2.8%(. Rational appeal in advertising of non-cariogenic food had the most frequency (64.9%). In contrast emotional appeal for cariogenic food was used more frequently (85.5%). For cariogenic foods, a soft-sell approach was used more frequently (95.5%). The most common artistic technique used in food advertising was music. Chemical and mechanical dental plaque control materials had a very low frequency (0.2%). Advertising of cariogenic foods in Iran TV has low frequency.

  5. Liquid chromatography method development and optimization for valsartan: pharmacokinetics of oral hydrogels in rabbits

    International Nuclear Information System (INIS)

    Sohail, M.; Minhas, M.U.

    2017-01-01

    A simple, rapid, precise, accurate high performance liquid chromatography method has been developed and subsequently validated for determination of valsartan in rabbit plasma. The method was developed employing mixture of mobile phase consisting of 0.02 M potassium dihydrogen phosphate buffer and acetonitrile (45:55), pH was adjusted to 2.7 using 50% orthophosphoric acid and pumped thorough chromatographic system at a flow rate of 1 ml/min. An isocratic elution mode was carried out at HPLC system (Agilent Technologies, 1200 series, USA) fitted with variable wavelength detector and data processing software ChemStation. For sample analysis, 20 mul sample was injected and eluate was monitored at 225nm wavelength. Pharmacokinetic evaluation was performed in rabbits after the oral administration of valsartan loaded PVA-co-poly(AA) hydrogels. The mean Cmax of valsartan was 408.439ng/ml, Tmax was 12h and half life (t1/2) was 8.812h. The extraction procedure was simple with good response even at very low drug concentration, thereby making this method suitable for pharmacokinetic application. It is concluded that developed method is simple, fast, cost effective, and reproducible for the analysis of pharmacokinetic parameters in the rabbit plasma. (author)

  6. Meta-analysis of two computer-assisted screening methods for diagnosing oral precancer and cancer.

    Science.gov (United States)

    Ye, Xiaojing; Zhang, Jing; Tan, Yaqin; Chen, Guanying; Zhou, Gang

    2015-11-01

    The early diagnosis of oral precancer and cancer is crucial and could have the highest impact on improving survival rates. A meta-analysis was conducted to compare the accuracy between the OralCDx brush biopsy and DNA-image cytometry in diagnosing both conditions. Bibliographic databases were systematically searched for original relevant studies on the early diagnosis of oral precancer and oral cancer. Study characteristics were evaluated to determine the accuracy of the two screening strategies. Thirteen studies (eight of OralCDx brush biopsy and five of DNA-image cytometry) were identified as having reported on 1981 oral mucosa lesions. The meta-analysis found that the area under the summary receiver operating characteristic curves of the OralCDx brush biopsy and DNA-image cytometry were 0.8879 and 0.9885, respectively. The pooled sensitivity, specificity, and diagnostic odds ratio of the OralCDx brush biopsy were 86% (95% CI 81-90), 81% (95% CI 78-85), and 20.36 (95% CI 2.72-152.67), respectively, while these modalities of DNA-image cytometry were 89% (95% CI 83-94), 99% (95% CI 97-100), and 446.08 (95% CI 73.36-2712.43), respectively. Results of a pairwise comparison between each modality demonstrated that specificity, area under the curve (AUC), and Q(∗) index of DNA-image cytometry was significantly higher than that of the OralCDx brush biopsy (Z=2.821, p0.05). In conclusion, the meta-analysis of the published studies indicated that DNA-image cytometry is more accurate than the OralCDx brush biopsy in diagnosing oral precancer and oral cancer. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Repeated topical treatment, in contrast to single oral doses, with Vitamin A-containing preparations does not affect plasma concentrations of retinol, retinyl esters or retinoic acids in female subjects of child-bearing age

    NARCIS (Netherlands)

    Nohynek, G.J.; Meuling, W.J.A.; Vaes, W.H.J.; Lawrence, R.S.; Shapiro, S.; Schulte, S.; Steiling, W.; Bausch, J.; Gerber, E.; Sasa, H.; Nau, H.

    2006-01-01

    Background: Vitamin A is widely used in cosmetic preparations. Given that oral Vitamin A and its metabolites present a potential reproductive risk, the present study investigated the effect of topical Vitamin A on human endogenous plasma levels of Vitamin A and its metabolites. Methods: Two groups

  8. A note on variational multiscale methods for high-contrast heterogeneous porous media flows with rough source terms

    KAUST Repository

    Calo, Victor M.

    2011-09-01

    In this short note, we discuss variational multiscale methods for solving porous media flows in high-contrast heterogeneous media with rough source terms. Our objective is to separate, as much as possible, subgrid effects induced by the media properties from those due to heterogeneous source terms. For this reason, enriched coarse spaces designed for high-contrast multiscale problems are used to represent the effects of heterogeneities of the media. Furthermore, rough source terms are captured via auxiliary correction equations that appear in the formulation of variational multiscale methods [23]. These auxiliary equations are localized and one can use additive or multiplicative constructions for the subgrid corrections as discussed in the current paper. Our preliminary numerical results show that one can capture the effects due to both spatial heterogeneities in the coefficients (such as permeability field) and source terms (e.g., due to singular well terms) in one iteration. We test the cases for both smooth source terms and rough source terms and show that with the multiplicative correction, the numerical approximations are more accurate compared to the additive correction. © 2010 Elsevier Ltd.

  9. Effectiveness of a Motivation and Practical Skills Development Methods on the Oral Hygiene of Orphans Children in Kaunas, Lithuania

    Directory of Open Access Journals (Sweden)

    Greta Markeviciute

    2015-09-01

    Full Text Available Objectives: The aim of this study was to evaluate the effect of a motivation and practical skills development methods on the oral hygiene of orphans. Material and Methods: Sixty eight orphans aged between 7 and 17 years from two orphanages in Kaunas were divided into two groups: practical application group and motivation group. Children were clinically examined by determining their oral hygiene status using Silness-Löe plaque index. Questionnaire was used to estimate the oral hygiene knowledge and practices at baseline and after 3 months. Statistical analysis included: Chi-square test (χ2, Fisher‘s exact test, Student‘s t-test, nonparametric Mann-Whitney test, Spearman’s rho correlation coefficient and Kappa coefficient. Results: All children had a plaque on at least one tooth in both groups: motivation 1.14 (SD 0.51, practical application 1.08 (SD 0.4 (P = 0.58. Girls in both groups showed significantly better oral hygiene than boys (P < 0.001. After 3 months educational program oral hygiene status improved in both groups significantly 0.4 (SD 0.35 (P < 0.001. Significantly better oral hygiene was determined in practical application group 0.19 (SD 0.27 in comparison with motivation group 0.55 (SD 0.32 (P < 0.001. By comparing results of first and second questionnaire surveys on use of soft drinks, the statistically significant decline of their use was in both groups (P = 0.004. Conclusions: Educational programs are effective in improving oral hygiene, especially when they’re based on practical skills training.

  10. Multi-frequency accelerating strategy for the contrast source inversion method of ultrasound waveform tomography using pulse data

    Science.gov (United States)

    Lin, Hongxiang; Azuma, Takashi; Qu, Xiaolei; Takagi, Shu

    2017-03-01

    In this work, we construct a multi-frequency accelerating strategy for the contrast source inversion (CSI) method using pulse data in the time domain. CSI is a frequency-domain inversion method for ultrasound waveform tomography that does not require the forward solver through the process of reconstruction. Several prior researches show that the CSI method has a good performance of convergence and accuracy in the low-center-frequency situation. In contrast, utilizing the high-center-frequency data leads to a high-resolution reconstruction but slow convergence on large numbers of grid. Our objective is to take full advantage of all low frequency components from pulse data with the high-center-frequency data measured by the diagnostic device. First we process the raw data in the frequency domain. Then multi-frequency accelerating strategy helps restart CSI in the current frequency using the last iteration result obtained from the lower frequency component. The merit of multi- frequency accelerating strategy is that computational burden decreases at the first few iterations. Because the low frequency component of dataset computes on the coarse grid with assuming a fixed number of points per wavelength. In the numerical test, the pulse data were generated by the K-wave simulator and have been processed to meet the computation of the CSI method. We investigate the performance of the multi-frequency and single-frequency reconstructions and conclude that the multi-frequency accelerating strategy significantly enhances the quality of the reconstructed image and simultaneously reduces the average computational time for any iteration step.

  11. Exploring the Oral Communication Strategies Used by Turkish EFL Learners: A Mixed Methods Study

    Science.gov (United States)

    Demir, Yusuf; Mutlu, Gülçin; Sisman, Yavuz Selim

    2018-01-01

    This study set out with a threefold purpose: to examine (1) the oral communication strategies (CSs) employed by tertiary-level Turkish EFL learners, (2) the use of CSs based on exposure to English through audio-visual tools, university subject domain and gender differences, (3) the correlation between use of CSs and oral proficiency scores. To…

  12. SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

    Energy Technology Data Exchange (ETDEWEB)

    Chacko, M; Aldoohan, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT

  13. An Investigation into Native and Non-Native Teachers' Judgments of Oral English Performance: A Mixed Methods Approach

    Science.gov (United States)

    Kim, Youn-Hee

    2009-01-01

    This study used a mixed methods research approach to examine how native English-speaking (NS) and non-native English-speaking (NNS) teachers assess students' oral English performance. The evaluation behaviors of two groups of teachers (12 Canadian NS teachers and 12 Korean NNS teachers) were compared with regard to internal consistency, severity,…

  14. Space-time relationship in continuously moving table method for large FOV peripheral contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Sabati, M; Lauzon, M L; Frayne, R

    2003-01-01

    Data acquisition using a continuously moving table approach is a method capable of generating large field-of-view (FOV) 3D MR angiograms. However, in order to obtain venous contamination-free contrast-enhanced (CE) MR angiograms in the lower limbs, one of the major challenges is to acquire all necessary k-space data during the restricted arterial phase of the contrast agent. Preliminary investigation on the space-time relationship of continuously acquired peripheral angiography is performed in this work. Deterministic and stochastic undersampled hybrid-space (x, k y , k z ) acquisitions are simulated for large FOV peripheral runoff studies. Initial results show the possibility of acquiring isotropic large FOV images of the entire peripheral vascular system. An optimal trade-off between the spatial and temporal sampling properties was found that produced a high-spatial resolution peripheral CE-MR angiogram. The deterministic sampling pattern was capable of reconstructing the global structure of the peripheral arterial tree and showed slightly better global quantitative results than stochastic patterns. Optimal stochastic sampling patterns, on the other hand, enhanced small vessels and had more favourable local quantitative results. These simulations demonstrate the complex spatial-temporal relationship when sampling large FOV peripheral runoff studies. They also suggest that more investigation is required to maximize image quality as a function of hybrid-space coverage, acquisition repetition time and sampling pattern parameters

  15. Automated Method for the Rapid and Precise Estimation of Adherent Cell Culture Characteristics from Phase Contrast Microscopy Images

    Science.gov (United States)

    Jaccard, Nicolas; Griffin, Lewis D; Keser, Ana; Macown, Rhys J; Super, Alexandre; Veraitch, Farlan S; Szita, Nicolas

    2014-01-01

    The quantitative determination of key adherent cell culture characteristics such as confluency, morphology, and cell density is necessary for the evaluation of experimental outcomes and to provide a suitable basis for the establishment of robust cell culture protocols. Automated processing of images acquired using phase contrast microscopy (PCM), an imaging modality widely used for the visual inspection of adherent cell cultures, could enable the non-invasive determination of these characteristics. We present an image-processing approach that accurately detects cellular objects in PCM images through a combination of local contrast thresholding and post hoc correction of halo artifacts. The method was thoroughly validated using a variety of cell lines, microscope models and imaging conditions, demonstrating consistently high segmentation performance in all cases and very short processing times (image). Based on the high segmentation performance, it was possible to precisely determine culture confluency, cell density, and the morphology of cellular objects, demonstrating the wide applicability of our algorithm for typical microscopy image processing pipelines. Furthermore, PCM image segmentation was used to facilitate the interpretation and analysis of fluorescence microscopy data, enabling the determination of temporal and spatial expression patterns of a fluorescent reporter. We created a software toolbox (PHANTAST) that bundles all the algorithms and provides an easy to use graphical user interface. Source-code for MATLAB and ImageJ is freely available under a permissive open-source license. Biotechnol. Bioeng. 2014;111: 504–517. © 2013 Wiley Periodicals, Inc. PMID:24037521

  16. The structure of carbon black-elastomer composites by small-angle neutron scattering and the method of contrast variation

    International Nuclear Information System (INIS)

    Hjelm, R.P.; Wampler, W.; Gerspacher, M.

    1996-01-01

    We have been exploring the use of small-angle neutron scattering and the method of contrast variation to give a new look at a very old problem: reinforcement of elastomers by carbon black in durable rubber products. Carbon black has a hierarchy of structures consisting of particles covalently bound into aggregates, which in turn associate by weak interactions into agglomerates. We found that in one carbon black, HSA, the aggregates are rodlike, containing an average of 4-6 particles. The aggregates have an outer graphitic shell and an inner core of lower density carbon. The core is continuous throughout the carbon black aggregate. Contrast variation of swollen HSA-polyisoprene gels shows that the HSA is completely embedded in polyisoprene and that the agglomerates are formed predominantly by end on associations of the rodlike aggregates. The surface structure of the carbon black appears smooth over length scales above about 10 angstrom. Further studies using production carbon blacks suggest that these structural characteristics are generally present in commercial rubber composites

  17. Prognostic potential of n-cadherin in oral squamous cell carcinoma via immunohistochemical methods

    International Nuclear Information System (INIS)

    Chandolia, B.; Arora, M.; Rajliwal, P.

    2017-01-01

    To assess the prognostic potential for N-cadherin in oral squamous cell carcinoma and oral epithelial dysplasia. Study Design: A cross-sectional study, analytical study. Place and Duration of Study: Maharishi Markandeshwar College of Dental Science Research (MMCDSR), Ambala, India, from 2011 to 2014. Methodology: Immunohistochemistry was used to observe the N-cadherin expression in 100 cases having epithelium with normal oral mucosa, oral epithelial dysplastic lesions and oral squamous cell carcinoma (OSCC). For statistical significance, SPSS 13.0 was used to calculate the data by Mann-Whitney and Kruskal-Wallis tests. Results: In OSCC, N-cadherin expression was more evident than in oral epithelial dysplasia followed by the normal oral epithelium that did not show any dysplastic changes (p=0.001). Conversely, N-cadherin expression was not significant among the histological grade of OSCC. Conclusion: N-cadherin can be used as a potential biomarker for early diagnosis of OSCC. However, the N-cadherin expression did not show any correlation with the histological grade of OSCC. (author)

  18. Prognostic Potential of N-Cadherin in Oral Squamous Cell Carcinoma via Immunohistochemical Methods.

    Science.gov (United States)

    Chandolia, Betina; Rajliwal, Jai Parkash; Bajpai, Manas; Arora, Manika

    2017-08-01

    To assess the prognostic potential for N-cadherin in oral squamous cell carcinoma and oral epithelial dysplasia. Across-sectional study, analytical study. Maharishi Markandeshwar College of Dental Science Research (MMCDSR), Ambala, India, from 2011 to 2014. Immunohistochemistry was used to observe the N-cadherin expression in 100 cases having epithelium with normal oral mucosa, oral epithelial dysplastic lesions and oral squamous cell carcinoma (OSCC). For statistical significance, SPSS 13.0 was used to calculate the data by Mann-Whitney and Kruskal-Wallis tests. In OSCC, N-cadherin expression was more evident than in oral epithelial dysplasia followed by the normal oral epithelium that did not show any dysplastic changes (p=0.001). Conversely, N-cadherin expression was not significant among the histological grade of OSCC. N-cadherin can be used as a potential biomarker for early diagnosis of OSCC. However, the N-cadherin expression did not show any correlation with the histological grade of OSCC.

  19. Spatiotemporal analysis and mapping of oral cancer risk in changhua county (taiwan): an application of generalized bayesian maximum entropy method.

    Science.gov (United States)

    Yu, Hwa-Lung; Chiang, Chi-Ting; Lin, Shu-De; Chang, Tsun-Kuo

    2010-02-01

    Incidence rate of oral cancer in Changhua County is the highest among the 23 counties of Taiwan during 2001. However, in health data analysis, crude or adjusted incidence rates of a rare event (e.g., cancer) for small populations often exhibit high variances and are, thus, less reliable. We proposed a generalized Bayesian Maximum Entropy (GBME) analysis of spatiotemporal disease mapping under conditions of considerable data uncertainty. GBME was used to study the oral cancer population incidence in Changhua County (Taiwan). Methodologically, GBME is based on an epistematics principles framework and generates spatiotemporal estimates of oral cancer incidence rates. In a way, it accounts for the multi-sourced uncertainty of rates, including small population effects, and the composite space-time dependence of rare events in terms of an extended Poisson-based semivariogram. The results showed that GBME analysis alleviates the noises of oral cancer data from population size effect. Comparing to the raw incidence data, the maps of GBME-estimated results can identify high risk oral cancer regions in Changhua County, where the prevalence of betel quid chewing and cigarette smoking is relatively higher than the rest of the areas. GBME method is a valuable tool for spatiotemporal disease mapping under conditions of uncertainty. 2010 Elsevier Inc. All rights reserved.

  20. Effectiveness of a Motivation and Practical Skills Development Methods on the Oral Hygiene of Orphans Children in Kaunas, Lithuania.

    Science.gov (United States)

    Markeviciute, Greta; Narbutaite, Julija

    2015-01-01

    The aim of this study was to evaluate the effect of a motivation and practical skills development methods on the oral hygiene of orphans. Sixty eight orphans aged between 7 and 17 years from two orphanages in Kaunas were divided into two groups: practical application group and motivation group. Children were clinically examined by determining their oral hygiene status using Silness-Löe plaque index. Questionnaire was used to estimate the oral hygiene knowledge and practices at baseline and after 3 months. Statistical analysis included: Chi-square test (χ(2)), Fisher's exact test, Student's t-test, nonparametric Mann-Whitney test, Spearman's rho correlation coefficient and Kappa coefficient. All children had a plaque on at least one tooth in both groups: motivation 1.14 (SD 0.51), practical application 1.08 (SD 0.4) (P = 0.58). Girls in both groups showed significantly better oral hygiene than boys (P soft drinks, the statistically significant decline of their use was in both groups (P = 0.004). Educational programs are effective in improving oral hygiene, especially when they're based on practical skills training.

  1. Surgiplanner: a new method for one step oral rehabilitation of severe atrophic maxilla.

    Science.gov (United States)

    Busato, A; Vismara, V; Grecchi, F; Grecchi, E; Lauritano, D

    2017-01-01

    The implant-prosthetic rehabilitation of edentulous upper jaws has always been complex for surgeons and dentists. The lack of bone in both vertical and horizontal dimension does not allow the correct insertion of dental implants. In addition, patients with edentulous upper and lower arch have a loss of vertical dimension of the face and an aged expression. Many surgical techniques have been proposed to increase the bone volume, height and thickness, such as the Le Fort I osteotomy, the bone grafts and the placement of dental implants. Planning these surgical procedures is difficult, because it is not possible to reproduce the movements of osteotomized bone segments in three planes of space. This article describes the treatment of severe atrophy maxilla with a new approach using a new instrument named "Surgiplanner". Surgiplanner is a method that, only using a computerized axial tomography (CAT), allows to obtain a totally predetermined therapeutic result from both an aesthetic and functional point of view, with surgery of severe resorbed jaws. Surgiplanner allows repositioning of segment of the skeleton of the patient's face in a predetermined and controlled way for the best implant-supported oral rehabilitation.

  2. Laboratory assessment of novel oral anticoagulants: method suitability and variability between coagulation laboratories.

    Science.gov (United States)

    Helin, Tuukka A; Pakkanen, Anja; Lassila, Riitta; Joutsi-Korhonen, Lotta

    2013-05-01

    Laboratory tests to assess novel oral anticoagulants (NOACs) are under evaluation. Routine monitoring is unnecessary, but under special circumstances bioactivity assessment becomes crucial. We analyzed the effects of NOACs on coagulation tests and the availability of specific assays at different laboratories. Plasma samples spiked with dabigatran (Dabi; 120 and 300 μg/L) or rivaroxaban (Riva; 60, 146, and 305 μg/L) were sent to 115 and 38 European laboratories, respectively. International normalized ratio (INR) and activated partial thromboplastin time (APTT) were analyzed for all samples; thrombin time (TT) was analyzed specifically for Dabi and calibrated anti-activated factor X (anti-Xa) activity for Riva. We compared the results with patient samples. Results of Dabi samples were reported by 73 laboratories (13 INR and 9 APTT reagents) and Riva samples by 22 laboratories (5 INR and 4 APTT reagents). Both NOACs increased INR values; the increase was modest, albeit larger, for Dabi, with higher CV, especially with Quick (vs Owren) methods. Both NOACs dose-dependently prolonged the APTT. Again, the prolongation and CVs were larger for Dabi. The INR and APTT results varied reagent-dependently (P laboratories, respectively. The screening tests INR and APTT are suboptimal in assessing NOACs, having high reagent dependence and low sensitivity and specificity. They may provide information, if laboratories recognize their limitations. The variation will likely increase and the sensitivity differ in clinical samples. Specific assays measure NOACs accurately; however, few laboratories applied them. © 2013 American Association for Clinical Chemistry.

  3. Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods

    International Nuclear Information System (INIS)

    Beichel, Reinhard; Bornik, Alexander; Bauer, Christian; Sorantin, Erich

    2012-01-01

    Purpose: Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. Methods: A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and/or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Results: Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of

  4. Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods

    Energy Technology Data Exchange (ETDEWEB)

    Beichel, Reinhard; Bornik, Alexander; Bauer, Christian; Sorantin, Erich [Departments of Electrical and Computer Engineering and Internal Medicine, Iowa Institute for Biomedical Imaging, University of Iowa, Iowa City, Iowa 52242 (United States); Institute for Computer Graphics and Vision, Graz University of Technology, Inffeldgasse 16, A-8010 Graz (Austria); Department of Electrical and Computer Engineering, Iowa Institute for Biomedical Imaging, University of Iowa, Iowa City, Iowa 52242 (United States); Department of Radiology, Medical University Graz, Auenbruggerplatz 34, A-8010 Graz (Austria)

    2012-03-15

    Purpose: Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. Methods: A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and/or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Results: Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of

  5. Laser Raman detection for oral cancer based on an adaptive Gaussian process classification method with posterior probabilities

    International Nuclear Information System (INIS)

    Du, Zhanwei; Yang, Yongjian; Bai, Yuan; Wang, Lijun; Su, Le; Chen, Yong; Li, Xianchang; Zhou, Xiaodong; Shen, Aiguo; Hu, Jiming; Jia, Jun

    2013-01-01

    The existing methods for early and differential diagnosis of oral cancer are limited due to the unapparent early symptoms and the imperfect imaging examination methods. In this paper, the classification models of oral adenocarcinoma, carcinoma tissues and a control group with just four features are established by utilizing the hybrid Gaussian process (HGP) classification algorithm, with the introduction of the mechanisms of noise reduction and posterior probability. HGP shows much better performance in the experimental results. During the experimental process, oral tissues were divided into three groups, adenocarcinoma (n = 87), carcinoma (n = 100) and the control group (n = 134). The spectral data for these groups were collected. The prospective application of the proposed HGP classification method improved the diagnostic sensitivity to 56.35% and the specificity to about 70.00%, and resulted in a Matthews correlation coefficient (MCC) of 0.36. It is proved that the utilization of HGP in LRS detection analysis for the diagnosis of oral cancer gives accurate results. The prospect of application is also satisfactory. (paper)

  6. Laser Raman detection for oral cancer based on an adaptive Gaussian process classification method with posterior probabilities

    Science.gov (United States)

    Du, Zhanwei; Yang, Yongjian; Bai, Yuan; Wang, Lijun; Su, Le; Chen, Yong; Li, Xianchang; Zhou, Xiaodong; Jia, Jun; Shen, Aiguo; Hu, Jiming

    2013-03-01

    The existing methods for early and differential diagnosis of oral cancer are limited due to the unapparent early symptoms and the imperfect imaging examination methods. In this paper, the classification models of oral adenocarcinoma, carcinoma tissues and a control group with just four features are established by utilizing the hybrid Gaussian process (HGP) classification algorithm, with the introduction of the mechanisms of noise reduction and posterior probability. HGP shows much better performance in the experimental results. During the experimental process, oral tissues were divided into three groups, adenocarcinoma (n = 87), carcinoma (n = 100) and the control group (n = 134). The spectral data for these groups were collected. The prospective application of the proposed HGP classification method improved the diagnostic sensitivity to 56.35% and the specificity to about 70.00%, and resulted in a Matthews correlation coefficient (MCC) of 0.36. It is proved that the utilization of HGP in LRS detection analysis for the diagnosis of oral cancer gives accurate results. The prospect of application is also satisfactory.

  7. Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (I): Theory, method, and phantom experiments

    NARCIS (Netherlands)

    van Schie, Jeroen J. N.; Lavini, Cristina; van Vliet, Lucas J.; Vos, Frans M.

    2017-01-01

    The arterial input function (AIF) represents the time-dependent arterial contrast agent (CA) concentration that is used in pharmacokinetic modeling. To develop a novel method for estimating the AIF from dynamic contrast-enhanced (DCE-) MRI data, while compensating for flow enhancement. Signal

  8. Analysis of an automated background correction method for cardiovascular MR phase contrast imaging in children and young adults

    Energy Technology Data Exchange (ETDEWEB)

    Rigsby, Cynthia K.; Hilpipre, Nicholas; Boylan, Emma E.; Popescu, Andrada R.; Deng, Jie [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); McNeal, Gary R. [Siemens Medical Solutions USA Inc., Customer Solutions Group, Cardiovascular MR R and D, Chicago, IL (United States); Zhang, Gang [Ann and Robert H. Lurie Children' s Hospital of Chicago Research Center, Biostatistics Research Core, Chicago, IL (United States); Choi, Grace [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Greiser, Andreas [Siemens AG Healthcare Sector, Erlangen (Germany)

    2014-03-15

    Phase contrast magnetic resonance imaging (MRI) is a powerful tool for evaluating vessel blood flow. Inherent errors in acquisition, such as phase offset, eddy currents and gradient field effects, can cause significant inaccuracies in flow parameters. These errors can be rectified with the use of background correction software. To evaluate the performance of an automated phase contrast MRI background phase correction method in children and young adults undergoing cardiac MR imaging. We conducted a retrospective review of patients undergoing routine clinical cardiac MRI including phase contrast MRI for flow quantification in the aorta (Ao) and main pulmonary artery (MPA). When phase contrast MRI of the right and left pulmonary arteries was also performed, these data were included. We excluded patients with known shunts and metallic implants causing visible MRI artifact and those with more than mild to moderate aortic or pulmonary stenosis. Phase contrast MRI of the Ao, mid MPA, proximal right pulmonary artery (RPA) and left pulmonary artery (LPA) using 2-D gradient echo Fast Low Angle SHot (FLASH) imaging was acquired during normal respiration with retrospective cardiac gating. Standard phase image reconstruction and the automatic spatially dependent background-phase-corrected reconstruction were performed on each phase contrast MRI dataset. Non-background-corrected and background-phase-corrected net flow, forward flow, regurgitant volume, regurgitant fraction, and vessel cardiac output were recorded for each vessel. We compared standard non-background-corrected and background-phase-corrected mean flow values for the Ao and MPA. The ratio of pulmonary to systemic blood flow (Qp:Qs) was calculated for the standard non-background and background-phase-corrected data and these values were compared to each other and for proximity to 1. In a subset of patients who also underwent phase contrast MRI of the MPA, RPA, and LPA a comparison was made between standard non

  9. A Real-Time Near-Infrared Fluorescence Imaging Method for the Detection of Oral Cancers in Mice Using an Indocyanine Green-Labeled Podoplanin Antibody.

    Science.gov (United States)

    Ito, Akihiro; Ohta, Mitsuhiko; Kato, Yukinari; Inada, Shunko; Kato, Toshio; Nakata, Susumu; Yatabe, Yasushi; Goto, Mitsuo; Kaneda, Norio; Kurita, Kenichi; Nakanishi, Hayao; Yoshida, Kenji

    2018-01-01

    Podoplanin is distinctively overexpressed in oral squamous cell carcinoma than oral benign neoplasms and plays a crucial role in the pathogenesis and metastasis of oral squamous cell carcinoma but its diagnostic application is quite limited. Here, we report a new near-infrared fluorescence imaging method using an indocyanine green (ICG)-labeled anti-podoplanin antibody and a desktop/a handheld ICG detection device for the visualization of oral squamous cell carcinoma-xenografted tumors in nude mice. Both near-infrared imaging methods using a desktop (in vivo imaging system: IVIS) and a handheld device (photodynamic eye: PDE) successfully detected oral squamous cell carcinoma tumors in nude mice in a podoplanin expression-dependent manner with comparable sensitivity. Of these 2 devices, only near-infrared imaging methods using a handheld device visualized oral squamous cell carcinoma xenografts in mice in real time. Furthermore, near-infrared imaging methods using the handheld device (PDE) could detect smaller podoplanin-positive oral squamous cell carcinoma tumors than a non-near-infrared, autofluorescence-based imaging method. Based on these results, a near-infrared imaging method using an ICG-labeled anti-podoplanin antibody and a handheld detection device (PDE) allows the sensitive, semiquantitative, and real-time imaging of oral squamous cell carcinoma tumors and therefore represents a useful tool for the detection and subsequent monitoring of malignant oral neoplasms in both preclinical and some clinical settings.

  10. A novel anisotropic fast marching method and its application to blood flow computation in phase-contrast MRI.

    Science.gov (United States)

    Schwenke, M; Hennemuth, A; Fischer, B; Friman, O

    2012-01-01

    Phase-contrast MRI (PC MRI) can be used to assess blood flow dynamics noninvasively inside the human body. The acquired images can be reconstructed into flow vector fields. Traditionally, streamlines can be computed based on the vector fields to visualize flow patterns and particle trajectories. The traditional methods may give a false impression of precision, as they do not consider the measurement uncertainty in the PC MRI images. In our prior work, we incorporated the uncertainty of the measurement into the computation of particle trajectories. As a major part of the contribution, a novel numerical scheme for solving the anisotropic Fast Marching problem is presented. A computing time comparison to state-of-the-art methods is conducted on artificial tensor fields. A visual comparison of healthy to pathological blood flow patterns is given. The comparison shows that the novel anisotropic Fast Marching solver outperforms previous schemes in terms of computing time. The visual comparison of flow patterns directly visualizes large deviations of pathological flow from healthy flow. The novel anisotropic Fast Marching solver efficiently resolves even strongly anisotropic path costs. The visualization method enables the user to assess the uncertainty of particle trajectories derived from PC MRI images.

  11. Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods.

    Science.gov (United States)

    Beichel, Reinhard; Bornik, Alexander; Bauer, Christian; Sorantin, Erich

    2012-03-01

    Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and∕or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of user interaction

  12. Evaluation of Etest and macrodilution broth method for antifungal susceptibility testing of Candida sp strains isolated from oral cavities of AIDS patients

    Directory of Open Access Journals (Sweden)

    SILVA Maria do Rosário R.

    2002-01-01

    Full Text Available A comparison of the Etest and the reference broth macrodilution susceptibility test for fluconazole, ketoconazole, itraconazole and amphotericin B was performed with 59 of Candida species isolated from the oral cavities of AIDS patients. The Etest method was performed according to the manufacturer's instructions, and the reference method was performed according to National Committee for Clinical Laboratory Standards document M27-A guidelines. Our data showed that there was a good correlation between the MICs obtained by the Etest and broth dilution methods. When only the MIC results at ± 2 dilutions for both methods were considered, the agreement rates were 90.4% for itraconazole, ketoconazole and amphotericin B and 84.6% for fluconazole of the C. albicans tested. In contrast, to the reference method, the Etest method classified as susceptible three fluconazole-resistant isolates and one itraconazole-resistant isolate, representing four very major errors. These results indicate that Etest could be considered useful for antifungal sensitivity evaluation of yeasts in clinical laboratories.

  13. A randomized prospective triaI comparing oral sodium phosphate with magnesium citrate in preparing of patients for double contrast barium enema

    International Nuclear Information System (INIS)

    Lee, Eun Joo; Lee, Sung Woo; Lee, Hyeon Kyeong; Yang, Chang Hun; Kim, Soon; Oh, Yoen Hee; Kim, Seung Hyeon

    2004-01-01

    The purpose of this study was to compare two bowel preparation agents, sodium phosphate solution with magnesium citrate solution. A total of 94 subjects that underwent a double-contrast barium enema were included in this study. Bowel preparation before performing the barium study was done by using a sodium phosphate solution in 47 subjects and by using a magnesium citrate solution in the other 47 subjects. We evaluated the presence or absence of side effects when using these bowel preparation agents. Two radiologist who were blinded to the type of bowel preparation evaluated the quality of bowel preparation at the colonic segments (ascending, descending, and sigmoid colon) on the radiographs obtained by double-contrast barium enema, with regard to stool cleansing, water retention, barium coating and bubble formation. The side effects, such as abdominal clamping pain, nausea, hunger pain and chill occurred more frequently in the sodium phosphate group than in the magnesium citrate group (p< 0.001). Stool retention was more frequently found in the magnesium citrate group (p< 0.001). However, no statistical difference was noted on the status of water retention and barium coating between two groups. Gas bubble formation was more commonly seen in the sodium phosphate group (p< 0.001). The sodium phosphate solution appeared to be more effective in cleansing the right colon (p=0.001). Sodium phosphate solution appears to be more effective for colonic cleansing, with a lower incidence of side effects, than when using magnesium citrate solution

  14. Contrast Materials

    Science.gov (United States)

    ... is mixed with water before administration liquid paste tablet When iodine-based and barium-sulfate contrast materials ... for patients with kidney failure or allergies to MRI and/or computed tomography (CT) contrast material. Microbubble ...

  15. Dental plaque as a biofilm - a risk in oral cavity and methods to prevent

    OpenAIRE

    Renata Chałas; Ilona Wójcik-Chęcińska; Michał J. Woźniak; Justyna Grzonka; Wojciech Święszkowski; Krzysztof J. Kurzydłowski

    2015-01-01

    Bacteria living constantly in the oral cavity are in the form of a biofilm. The biofilm formed on a solid base such as the enamel of the teeth, fillings, restorations, orthodontic appliances or obturators is dental plaque. Disturbance of homeostasis of biofilm, excessive growth or increase in the number of acid-forming bacteria leads to the development of the most common diseases of the oral cavity, i.e. dental caries and periodontal disease. The presence of bacterial biofilm on the walls of ...

  16. Validation of an analytical method applicable to study of 1 mg/mL oral Risperidone solution stability

    International Nuclear Information System (INIS)

    Abreu Alvarez, Maikel; Garcia Penna, Caridad Margarita; Martinez Miranda, Lissette

    2010-01-01

    A validated analytical method by high-performance liquid chromatography (HPLC) was applicable to study of 1 mg/mL Risperidone oral solution stability. The above method was linear, accurate, specific and exact. A stability study of the 1 mg/mL Risperidone oral solution was developed determining its expiry date. The shelf life study was conducted for 24 months at room temperature; whereas the accelerated stability study was conducted with product under influence of humidity and temperature; analysis was made during 3 months. Formula fulfilled the quality specifications described in Pharmacopeia. The results of stability according to shelf life after 24 months showed that the product maintains the parameters determining its quality during this time and in accelerated studies there was not significant degradation (p> 0.05) in the product. Under mentioned conditions expiry date was of 2 years

  17. Comparison of Boiling and Robotics Automation Method in DNA Extraction for Metagenomic Sequencing of Human Oral Microbes.

    Science.gov (United States)

    Yamagishi, Junya; Sato, Yukuto; Shinozaki, Natsuko; Ye, Bin; Tsuboi, Akito; Nagasaki, Masao; Yamashita, Riu

    2016-01-01

    The rapid improvement of next-generation sequencing performance now enables us to analyze huge sample sets with more than ten thousand specimens. However, DNA extraction can still be a limiting step in such metagenomic approaches. In this study, we analyzed human oral microbes to compare the performance of three DNA extraction methods: PowerSoil (a method widely used in this field), QIAsymphony (a robotics method), and a simple boiling method. Dental plaque was initially collected from three volunteers in the pilot study and then expanded to 12 volunteers in the follow-up study. Bacterial flora was estimated by sequencing the V4 region of 16S rRNA following species-level profiling. Our results indicate that the efficiency of PowerSoil and QIAsymphony was comparable to the boiling method. Therefore, the boiling method may be a promising alternative because of its simplicity, cost effectiveness, and short handling time. Moreover, this method was reliable for estimating bacterial species and could be used in the future to examine the correlation between oral flora and health status. Despite this, differences in the efficiency of DNA extraction for various bacterial species were observed among the three methods. Based on these findings, there is no "gold standard" for DNA extraction. In future, we suggest that the DNA extraction method should be selected on a case-by-case basis considering the aims and specimens of the study.

  18. Comparison of Boiling and Robotics Automation Method in DNA Extraction for Metagenomic Sequencing of Human Oral Microbes.

    Directory of Open Access Journals (Sweden)

    Junya Yamagishi

    Full Text Available The rapid improvement of next-generation sequencing performance now enables us to analyze huge sample sets with more than ten thousand specimens. However, DNA extraction can still be a limiting step in such metagenomic approaches. In this study, we analyzed human oral microbes to compare the performance of three DNA extraction methods: PowerSoil (a method widely used in this field, QIAsymphony (a robotics method, and a simple boiling method. Dental plaque was initially collected from three volunteers in the pilot study and then expanded to 12 volunteers in the follow-up study. Bacterial flora was estimated by sequencing the V4 region of 16S rRNA following species-level profiling. Our results indicate that the efficiency of PowerSoil and QIAsymphony was comparable to the boiling method. Therefore, the boiling method may be a promising alternative because of its simplicity, cost effectiveness, and short handling time. Moreover, this method was reliable for estimating bacterial species and could be used in the future to examine the correlation between oral flora and health status. Despite this, differences in the efficiency of DNA extraction for various bacterial species were observed among the three methods. Based on these findings, there is no "gold standard" for DNA extraction. In future, we suggest that the DNA extraction method should be selected on a case-by-case basis considering the aims and specimens of the study.

  19. Evaluation of contrast reproduction method based on the anatomical guidance of the cerebral images reconstruction in positron emission tomography

    International Nuclear Information System (INIS)

    Bataille, F.

    2007-04-01

    Positron emission tomography is a medical imaging modality providing in-vivo volumetric images of functional processes of the human body, which is used for the diagnosis and the following of neuro degenerative diseases. PET efficiency is however limited by its poor spatial resolution, which generates a decrease of the image local contrast and leads to an under-estimation of small cerebral structures involved in the degenerative mechanism of those diseases. This so-called partial volume effect degradation is usually corrected in a post-reconstruction processing framework through the use of anatomical information, whose spatial resolution allows a better discrimination between functional tissues. However, this kind of method has the major drawback of being very sensitive to the residual mismatches on the anatomical information processing. We developed in this thesis an alternative methodology to compensate for the degradation, by incorporating in the reconstruction process both a model of the system impulse response and an anatomically-based image prior constraint. This methodology was validated by comparison with a post-reconstruction correction strategy, using data from an anthropomorphic phantom acquisition and then we evaluated its robustness to the residual mismatches through a realistic Monte Carlo simulation corresponding to a cerebral exam. The proposed algorithm was finally applied to clinical data reconstruction. (author)

  20. A novel Multiple-Marker Method for the Early Diagnosis of Oral Squamous Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Jutta Ries

    2009-01-01

    Full Text Available Objective: Melanoma associated antigens-A (MAGE-A expression is highly specific to cancer cells. Thus, they can be the most suitable targets for the diagnosis of malignancy. The aim of this study was to evaluate the sensitivity of multiple MAGE-A expression analysis for the diagnosis of oral squamous cell carcinoma (OSCC.

  1. Phase contrast image synthesis

    DEFF Research Database (Denmark)

    Glückstad, J.

    1996-01-01

    A new method is presented for synthesizing arbitrary intensity patterns based on phase contrast imaging. The concept is grounded on an extension of the Zernike phase contrast method into the domain of full range [0; 2 pi] phase modulation. By controlling the average value of the input phase funct...... function and by choosing appropriate phase retardation at the phase contrast filter, a pure phase to intensity imaging is accomplished. The method presented is also directly applicable in dark field image synthesis....

  2. Buccal swab, a minimally invasive method for the screening of oral cancer in active smokers

    Science.gov (United States)

    Suyatmi; Subiyantoro, P.; Indrakila, S.

    2018-05-01

    Smoking is the main risk factor for developing oral cancer. The previous study showed that there was a strong correlation between the length of smoking with the risk to develop oral cancer. Early detection of epithelial changes of oral mucosa will be a good prevention of the incidence of oral cancer among active smokers. This study evaluated the potential use of buccal swab for the screening of early signs of malignancy in active smokers. This study involved 80 participants including those who were smokers and non smokers. The buccal swab was conducted using sterile cytobrush. An epithelial smear was made from the buccal swab and stained with Papanicolaou’s technique. An cytomorphometric analysis was conducted by comparing the ratio of nuclear cell to cytoplasmic diameter (ND/CD) between the two groups. The mean of ND observed in this study were 8.963µ for active smokers and 7.991µ for non smokers groups. While the mean of CD were 58.249µ and 63.473µ for active smoker and non-smoker respectively. The mean of ND/CD ratio were 0.156 for active smokers and 0.129 for non smokers groups. This study detected a significant difference on the ND/CD ratio among active smokers vs non smokers (p<0.0001 95% CI = -0.040 – -0.014). In conclusion buccal swab could be a routine procedure to obtain sample for identification of changes in cells morphology to screen an early development of oral cancer.

  3. Oral cancer prognosis based on clinicopathologic and genomic markers using a hybrid of feature selection and machine learning methods

    Science.gov (United States)

    2013-01-01

    Background Machine learning techniques are becoming useful as an alternative approach to conventional medical diagnosis or prognosis as they are good for handling noisy and incomplete data, and significant results can be attained despite a small sample size. Traditionally, clinicians make prognostic decisions based on clinicopathologic markers. However, it is not easy for the most skilful clinician to come out with an accurate prognosis by using these markers alone. Thus, there is a need to use genomic markers to improve the accuracy of prognosis. The main aim of this research is to apply a hybrid of feature selection and machine learning methods in oral cancer prognosis based on the parameters of the correlation of clinicopathologic and genomic markers. Results In the first stage of this research, five feature selection methods have been proposed and experimented on the oral cancer prognosis dataset. In the second stage, the model with the features selected from each feature selection methods are tested on the proposed classifiers. Four types of classifiers are chosen; these are namely, ANFIS, artificial neural network, support vector machine and logistic regression. A k-fold cross-validation is implemented on all types of classifiers due to the small sample size. The hybrid model of ReliefF-GA-ANFIS with 3-input features of drink, invasion and p63 achieved the best accuracy (accuracy = 93.81%; AUC = 0.90) for the oral cancer prognosis. Conclusions The results revealed that the prognosis is superior with the presence of both clinicopathologic and genomic markers. The selected features can be investigated further to validate the potential of becoming as significant prognostic signature in the oral cancer studies. PMID:23725313

  4. H-classic: a new method to identify classic articles in Implant Dentistry, Periodontics, and Oral Surgery.

    Science.gov (United States)

    De la Flor-Martínez, Maria; Galindo-Moreno, Pablo; Sánchez-Fernández, Elena; Piattelli, Adriano; Cobo, Manuel Jesus; Herrera-Viedma, Enrique

    2016-10-01

    The study of classic papers permits analysis of the past, present, and future of a specific area of knowledge. This type of analysis is becoming more frequent and more sophisticated. Our objective was to use the H-classics method, based on the h-index, to analyze classic papers in Implant Dentistry, Periodontics, and Oral Surgery (ID, P, and OS). First, an electronic search of documents related to ID, P, and OS was conducted in journals indexed in Journal Citation Reports (JCR) 2014 within the category 'Dentistry, Oral Surgery & Medicine'. Second, Web of Knowledge databases were searched using Mesh terms related to ID, P, and OS. Finally, the H-classics method was applied to select the classic articles in these disciplines, collecting data on associated research areas, document type, country, institutions, and authors. Of 267,611 documents related to ID, P, and OS retrieved from JCR journals (2014), 248 were selected as H-classics. They were published in 35 journals between 1953 and 2009, most frequently in the Journal of Clinical Periodontology (18.95%), the Journal of Periodontology (18.54%), International Journal of Oral and Maxillofacial Implants (9.27%), and Clinical Oral Implant Research (6.04%). These classic articles derived from the USA in 49.59% of cases and from Europe in 47.58%, while the most frequent host institution was the University of Gothenburg (17.74%) and the most frequent authors were J. Lindhe (10.48%) and S. Socransky (8.06%). The H-classics approach offers an objective method to identify core knowledge in clinical disciplines such as ID, P, and OS. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Pretest Score for Predicting Microbubble Contrast Agent Use in Stress Echocardiography: A Method to Increase Efficiency in the Echo Laboratory

    Directory of Open Access Journals (Sweden)

    Mathieu Bernier

    2009-01-01

    contrast. Logistic regression models were used to evaluate the association between individual characteristics and contrast use. An 11-point score was derived from the significant characteristics. Results. Variables associated with microbubble use were age, sex, smoking, presence of multiple risk factors, bodymass index (BMI, referral for dobutamine stress echocardiography, history of coronary artery disease, and abnormal baseline electrocardiogram. All variables except BMI were given a score of 1 if present and 0 if absent; BMI was given a score of 0 to 4 according to its value. An increased score was directly proportional to increased likelihood of contrast use. The score cutoff value to optimize sensitivity and specificity was 5. Conclusions. A pretest score can be computed from information available before imaging. It may facilitate contrast agent use through early identification of patients who are likely to benefit from improved endocardial border definition.

  6. Impact of temperature and time storage on the microbial detection of oral samples by Checkerboard DNA-DNA hybridization method.

    Science.gov (United States)

    do Nascimento, Cássio; dos Santos, Janine Navarro; Pedrazzi, Vinícius; Pita, Murillo Sucena; Monesi, Nadia; Ribeiro, Ricardo Faria; de Albuquerque, Rubens Ferreira

    2014-01-01

    Molecular diagnosis methods have been largely used in epidemiological or clinical studies to detect and quantify microbial species that may colonize the oral cavity in healthy or disease. The preservation of genetic material from samples remains the major challenge to ensure the feasibility of these methodologies. Long-term storage may compromise the final result. The aim of this study was to evaluate the effect of temperature and time storage on the microbial detection of oral samples by Checkerboard DNA-DNA hybridization. Saliva and supragingival biofilm were taken from 10 healthy subjects, aliquoted (n=364) and processed according to proposed protocols: immediate processing and processed after 2 or 4 weeks, and 6 or 12 months of storage at 4°C, -20°C and -80°C. Either total or individual microbial counts were recorded in lower values for samples processed after 12 months of storage, irrespective of temperatures tested. Samples stored up to 6 months at cold temperatures showed similar counts to those immediately processed. The microbial incidence was also significantly reduced in samples stored during 12 months in all temperatures. Temperature and time of oral samples storage have relevant impact in the detection and quantification of bacterial and fungal species by Checkerboard DNA-DNA hybridization method. Samples should be processed immediately after collection or up to 6 months if conserved at cold temperatures to avoid false-negative results. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Enhancing resolution and contrast in second-harmonic generation microscopy using an advanced maximum likelihood estimation restoration method

    Science.gov (United States)

    Sivaguru, Mayandi; Kabir, Mohammad M.; Gartia, Manas Ranjan; Biggs, David S. C.; Sivaguru, Barghav S.; Sivaguru, Vignesh A.; Berent, Zachary T.; Wagoner Johnson, Amy J.; Fried, Glenn A.; Liu, Gang Logan; Sadayappan, Sakthivel; Toussaint, Kimani C.

    2017-02-01

    Second-harmonic generation (SHG) microscopy is a label-free imaging technique to study collagenous materials in extracellular matrix environment with high resolution and contrast. However, like many other microscopy techniques, the actual spatial resolution achievable by SHG microscopy is reduced by out-of-focus blur and optical aberrations that degrade particularly the amplitude of the detectable higher spatial frequencies. Being a two-photon scattering process, it is challenging to define a point spread function (PSF) for the SHG imaging modality. As a result, in comparison with other two-photon imaging systems like two-photon fluorescence, it is difficult to apply any PSF-engineering techniques to enhance the experimental spatial resolution closer to the diffraction limit. Here, we present a method to improve the spatial resolution in SHG microscopy using an advanced maximum likelihood estimation (AdvMLE) algorithm to recover the otherwise degraded higher spatial frequencies in an SHG image. Through adaptation and iteration, the AdvMLE algorithm calculates an improved PSF for an SHG image and enhances the spatial resolution by decreasing the full-width-at-halfmaximum (FWHM) by 20%. Similar results are consistently observed for biological tissues with varying SHG sources, such as gold nanoparticles and collagen in porcine feet tendons. By obtaining an experimental transverse spatial resolution of 400 nm, we show that the AdvMLE algorithm brings the practical spatial resolution closer to the theoretical diffraction limit. Our approach is suitable for adaptation in micro-nano CT and MRI imaging, which has the potential to impact diagnosis and treatment of human diseases.

  8. Spleen dynamic contrast-enhanced magnetic resonance imaging as a new method for staging liver fibrosis in a piglet model.

    Directory of Open Access Journals (Sweden)

    Li Zhou

    Full Text Available OBJECTIVE: To explore spleen hemodynamic alteration in liver fibrosis with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI, and to determine how to stage liver fibrosis with spleen DCE-MRI parameters. MATERIALS AND METHODS: Sixteen piglets were prospectively used to model liver fibrosis staged by liver biopsy, and underwent spleen DCE-MRI on 0, 5th, 9th, 16th and 21st weekend after modeling this disease. DCE-MRI parameters including time to peak (TTP, positive enhancement integral (PEI, maximum slope of increase (MSI and maximum slope of decrease (MSD of spleen were measured, and statistically analyzed to stage this disease. RESULTS: Spearman's rank correlation tests showed that TTP tended to increase with increasing stages of liver fibrosis (r = 0.647, P0.05, and decreased from stage 2 to 4 (P0.05. Mann-Whitney tests demonstrated that TTP and PEI could classify fibrosis between stage 0 and 1-4, between 0-1 and 2-4, between 0-2 and 3-4, or between 0-3 and 4 (all P<0.01. MSD could discriminate between 0-2 and 3-4 (P = 0.006, or between 0-3 and 4 (P = 0.012. MSI could not differentiate between any two stages. Receiver operating characteristic analysis illustrated that area under receiver operating characteristic curve (AUC of TTP was larger than of PEI for classifying stage ≥1 and ≥2 (AUC = 0.851 and 0.783, respectively. PEI could best classify stage ≥3 and 4 (AUC = 0.903 and 0.96, respectively. CONCLUSION: Spleen DCE-MRI has potential to monitor spleen hemodynamic alteration and classify liver fibrosis stages.

  9. Methods and background characteristics of the TOHNN study: a population-based study of oral health conditions in northern Norway

    Science.gov (United States)

    Holde, Gro Eirin; Oscarson, Nils; Tillberg, Anders; Marstrander, Peter; Jönsson, Birgitta

    2016-01-01

    Objectives The aim of the Tromstannen – Oral Health in Northern Norway (TOHNN) study was to investigate oral health and dental-related diseases in an adult population. This article provides an overview of the background of the study and a description of the sample characteristics and methods employed in data collection. Study design Cross-sectional population-based study including a questionnaire and clinical dental examination. Methods A randomly selected sample of 2,909 individuals (20–79 years old) drawn from the population register was invited to participate in the study. The data were collected between October 2013 and November 2014 in Troms County in northern Norway. The questionnaire focused on oral health-related behaviours and attitudes, oral health-related quality of life, sense of coherence, dental anxiety and symptoms from the temporomandibular joint. The dental examinations, including radiographs, were conducted by 11 dental teams in 5 dental offices. The examination comprised of registration of dental caries, full mouth periodontal status, temporomandibular disorders, mucosal lesions and height and weight. The participants were grouped by age (20–34, 35–49, 50–64 and 65–79) and ethnicity (Norwegian, Sámi, other European and other world). Results From the original sample of 2,909 individuals, 1,986 (68.3%) people participated, of whom 1,019 (51.3%) were women. The highest attendance rate was among women 20–34 years old (80.3%) and the lowest in the oldest age group of women (55.4%). There was no difference in response rate between rural and urban areas. There was a positive correlation between population size and household gross income (p population in Troms County. Due to the high participation rate, generalization both nationally and to the circumpolar area ought to be possible. PMID:26900910

  10. Patient-generated aspects in oral rehabilitation decision making I. Comparison of traditional history taking and an individual systematic interview method

    DEFF Research Database (Denmark)

    Øzhayat, Esben Boeskov; Gotfredsen, Klaus; Elverdam, Beth

    2009-01-01

    it with a traditional history taking, in generating information to be used in decision making in oral rehabilitation. Fifty-seven participants in need of oral rehabilitation were enrolled in the study. The participants underwent a traditional history taking and were interviewed using the SEIQoL-DW method. The SEIQo......Decision making in oral rehabilitation is often based on diagnoses related to impairment of different oral functions. In making the decision when to treat, the dentist must work in cooperation with the patient. By incorporating patient-generated aspects into the decision making process, the dentist...... percentage of the participants were positive towards the use of the SEIQoL-DW method in their treatment planning. The SEIQoL-DW was considered to be a viable tool for decision making in oral rehabilitation....

  11. Multianalytical Method Validation for Qualitative and Quantitative Analysis of Solvents of Abuse in Oral Fluid by HS-GC/MS

    Directory of Open Access Journals (Sweden)

    Bruna Claudia Coppe

    2016-01-01

    Full Text Available The use of oral fluid as a biological matrix to monitor the use of drugs of abuse is a global trend because it presents several advantages and good correlation to the blood level. Thus, the present work aimed to develop and validate an analytical method for quantification and detection of solvents used as inhalants of abuse in oral fluid (OF, using Quantisal™ as collector device by headspace and gas chromatography coupled with a mass detector (HS-GC/MS. Chromatographic separation was performed with a ZB-BAC1 column and the total time of analysis was 11.8 min. The method showed good linearity (correlation coefficient higher than 0.99 for all solvents. The limits of detection ranged from 0.05 to 5 mg/L, while the lower limits of quantification ranged from 2.5 to 12.5 mg/L. Accuracy, precision, matrix effect, and residual effect presented satisfactory results, meeting the criteria accepted for the validation of bioanalytical methods. The method showed good selectivity considering that, for solvents coeluting at the same retention time, resolution was performed by the mass detector. The method developed proved to be adequate when applied in OF samples from users of drugs and may be used to monitor the abuse of inhalants in routine forensic analyses.

  12. Routine Use of Contrast Swallow After Total Gastrectomy and Esophagectomy: Is it Justified?

    Science.gov (United States)

    El-Sourani, Nader; Bruns, Helge; Troja, Achim; Raab, Hans-Rudolf; Antolovic, Dalibor

    2017-01-01

    After gastrectomy or esophagectomy, esophagogastrostomy and esophagojejunostomy are commonly used for reconstruction. Water-soluble contrast swallow is often used as a routine screening to exclude anastomotic leakage during the first postoperative week. In this retrospective study, the sensitivity and specificity of oral water-soluble contrast swallow for the detection of anastomotic leakage and its clinical symptoms were analysed. Records of 104 consecutive total gastrectomies and distal esophagectomies were analysed. In all cases, upper gastrointestinal contrast swallow with the use of a water-soluble contrast agent was performed on the 5 th postoperative day. Extravasation of the contrast agent was defined as anastomotic leakage. When anastomotic insufficiency was suspected but no extravasation was present, a computed tomography (CT) scan and upper endoscopy were performed. Oral contrast swallow detected 7 anastomotic leaks. Based on CT-scans and upper endoscopy, the true number of anastomotic leakage was 15. The findings of the oral contrast swallow were falsely positive in 4 and falsely negative in 12 patients, respectively. The sensitivity and specificity of the oral contrast swallow was 20% and 96%, respectively. Routine radiological contrast swallow following total gastrectomy or distal esophagectomy cannot be recommended. When symptoms of anastomotic leakage are present, a CT-scan and endoscopy are currently the methods of choice.

  13. Novel X-ray phase-contrast tomography method for quantitative studies of heat induced structural changes in meat

    DEFF Research Database (Denmark)

    Miklos, Rikke; Nielsen, Mikkel Schou; Einarsdottir, Hildur

    2014-01-01

    The objective of this study was to evaluate the use of X-ray phase-contrast tomography combined with 3D image segmentation to investigate the heat induced structural changes in meat. The measurements were performed at the Swiss synchrotron radiation light source using a grating interferometric...... and separated into a water phase and a gel phase formed by the sarcoplasmic proteins in the exudate. The results show that X-ray phase contrast tomography offers unique possibilities in studies both the meat structure and the different meat component such as water, fat, connective tissue and myofibrils...

  14. Chiral Analysis of Methamphetamine in Oral Fluid Samples: A Method to Distinguish Licit from Illicit Drug Use.

    Science.gov (United States)

    Borg, Damon; Kolb, Elizabeth; Lantigua, Cindy; Stripp, Richard

    2018-01-01

    Methamphetamine (MAMP) is a popular illicit drug abused for its central nervous system stimulating effects. MAMP is also used therapeutically in the treatment of overeating disorders, narcolepsy, attention deficit disorder, in over-the-counter (OTC) products to ease nasal congestion. MAMP exists in two enantiomeric forms, dextrorotary (d-MAMP) or levorotary (l-MAMP). The compounds are similar in chemical structure, simply differing in the orientation of functional groups around the asymmetric carbon. In part because of the availability of l-MAMP in OTC nasal inhalers, forensic guidelines require a sample to contain greater than 20% d-MAMP to consider illicit drug use when interpreting results. Standard analytical methods readily detect MAMP in biological specimens but cannot resolve the enantiomeric composition of the sample. Specialized analytical techniques based on chiral separation of the enantiomers are required to differentiate d-MAMP from l-MAMP. Our laboratory sought to develop and validate a method for the analysis of oral fluid specimens for d/l-MAMP using a chiral derivatizing agent and traditional reverse phase liquid chromatography tandem mass spectrometry (LC-MS-MS). MAMP was extracted from dilute oral fluid samples using Strata-XC solid phase extraction (SPE) cartridges and derivatized with Marfey's reagent. Chromatographic separation was achieved using Zorbax Eclipse Plus C18 columns. Linearity, accuracy and precision, recovery, matrix effects and specificity of the method were all within acceptable criteria. Intraday accuracy ranged from 93.3 to 103.4% and precision 0.1 to 1.6%. Interday accuracy ranged from 90.0 to 103.4% and precision 3.8 to 11.6%. Finally, having previously tested positive for MAMP using non-chiral analysis, 256 de-identified authentic oral fluid samples were analyzed using this validated method. 98% of all samples tested positive for d-MAMP at greater than 20%.

  15. Comparative analysis of Gram’s method and PAS for the identification of Candida spp. samples from the oral mucosa

    Directory of Open Access Journals (Sweden)

    Cátia Martins Leite Padilha

    2014-10-01

    Full Text Available Introduction: Candida species are part of the normal microbiota of healthy subjects, living as commensals. However, they can become pathogenic when changes in the mechanisms of host defense or disruption of anatomic barriers occur. Candidiasis is the most common fungal infection in the oral cavity, mainly caused by Candida albicans. The diagnosis is based on symptoms and clinical aspects, in association with laboratory methods. Objective: To evaluate the sensitivity and specificity of Gram’s method for Candida spp. identification in scrapes from the buccal mucosa and evaluate the degree of concordance between clinical and cytological methods in the diagnosis of oral candidiasis. Material and methods: A blind study was performed in 170 smears from patients of Hospital Universitário Antônio Pedro of Universidade Federal Fluminense (HUAP/UFF, stained by Gram (n = 57, periodic acid-Schiff (PAS (n = 57 and Papanicolaou (Pap (n = 57 methods. Results: The comparative analysis of the methods demonstrated a higher prevalence of Candida spp. (12% in PAS than in Gram staining, without statistic significance. The cytology method was positive in 93% of the clinical diagnosis of candidiasis. Conclusion: Gram was an adequate method; however more intensive professional training would be necessary to identify the fungus morphological structures. Although Pap test is the most common method of routine cytopathologic examination, for candidiasis diagnosis PAS staining is also recommended. Thus, it is suggested that candidiasis diagnosis should be accomplished by clinical evaluation in association with cytopathological analysis based on the identification of hyphae and/or pseudohyphae.

  16. Screening of extraction methods for glycoproteins from jellyfish ( Rhopilema esculentum) oral-arms by high performance liquid chromatography

    Science.gov (United States)

    Ren, Guoyan; Li, Bafang; Zhao, Xue; Zhuang, Yongliang; Yan, Mingyan; Hou, Hu; Zhang, Xiukun; Chen, Li

    2009-03-01

    In order to select an optimum extraction method for the target glycoprotein (TGP) from jellyfish ( Rhopilema esculentum) oral-arms, a high performance liquid chromatography (HPLC)-assay for the determination of the TGP was developed. Purified target glycoprotein was taken as a standard glycoprotein. The results showed that the calibration curves for peak area plotted against concentration for TGP were linear ( r = 0.9984, y = 4.5895 x+47.601) over concentrations ranging from 50 to 400 mgL-1. The mean extraction recovery was 97.84% (CV2.60%). The fractions containing TGP were isolated from jellyfish ( R. esculentum) oral-arms by four extraction methods: 1) water extraction (WE), 2) phosphate buffer solution (PBS) extraction (PE), 3) ultrasound-assisted water extraction (UA-WE), 4) ultrasound-assisted PBS extraction (UA-PE). The lyophilized extract was dissolved in Milli-Q water and analyzed directly on a short TSK-GEL G4000PWXL (7.8 mm×300 mm) column. Our results indicated that the UA-PE method was the optimum extraction method selected by HPLC.

  17. Marathon maternity oral history project: Exploring rural birthing through narrative methods.

    Science.gov (United States)

    Orkin, Aaron; Newbery, Sarah

    2014-01-01

    To explore how birthing and maternity care are understood and valued in a rural community. Oral history research. The rural community of Marathon, Ont, with a population of approximately 3500. A purposive selection of mothers, grandmothers, nurses, physicians, and community leaders in the Marathon medical catchment area. Interviews were conducted with a purposive sample, employing an oral history research methodology. Interviews were conducted non-anonymously in order to preserve the identity and personhood of participants. Interview transcripts were edited into short narratives. Oral histories offer perspectives and information not revealed in other quantitative or qualitative research methodologies. Narratives re-personalize and humanize medical research by offering researchers and practitioners the opportunity to bear witness to the personal stories affected through medical decision making. Eleven stand-alone narratives, published in this issue of Canadian Family Physician, form the project's findings. Similar to a literary text or short story, they are intended for personal reflection and interpretation by the reader. Presenting the results of these interviews as narratives requires the reader to participate in the research exercise and take part in listening to these women's voices. The project's narratives will be accessible to readers from academic and non-academic backgrounds and will interest readers in medicine and allied health professions, medical humanities, community development, gender studies, social anthropology and history, and literature. Sharing personal birthing experiences might inspire others to reevaluate and reconsider birthing practices and services in other communities. Where local maternity services are under threat, Marathon's stories might contribute to understanding the meaning and challenges of local birthing, and the implications of losing maternity services in rural Canada.

  18. Oral sex, oral health and orogenital infections

    Directory of Open Access Journals (Sweden)

    Rajiv Saini

    2010-01-01

    Full Text Available Oral sex is commonly practiced by sexually active male-female and same-gender couples of various ages, including adolescents. The various type of oral sex practices are fellatio, cunnilingus and analingus. Oral sex is infrequently examined in research on adolescents; oral sex can transmit oral, respiratory, and genital pathogens. Oral health has a direct impact on the transmission of infection; a cut in your mouth, bleeding gums, lip sores or broken skin increases chances of infection. Although oral sex is considered a low risk activity, it is important to use protection and safer sex precautions. There are various methods of preventing infection during oral sex such as physical barriers, health and medical issues, ethical issues and oral hygiene and dental issues. The lesions or unhealthy periodontal status of oral cavity accelerates the phenomenon of transmission of infections into the circulation. Thus consequences of unhealthy or painful oral cavity are significant and oral health should be given paramount importance for the practice of oral sex.

  19. Interobserver Variation of the Bolus-and-Burst Method for Pancreatic Perfusion with Dynamic – Contrast-Enhanced Ultrasound

    Czech Academy of Sciences Publication Activity Database

    Stangeland, M.; Engjom, T.; Mézl, M.; Jiřík, Radovan; Gilja, O.H.; Dimcevski, G.; Nylund, K.

    2017-01-01

    Roč. 3, č. 3 (2017), E99-E106 E-ISSN 2199-7152 Institutional support: RVO:68081731 Keywords : interobserver * dynamic contrast-enhanced ultrasound * perfusion * pancreas Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Medical engineering https://www.thieme-connect.com/products/ejournals/abstract/10.1055/s-0043-110475

  20. Digital subtraction in gadolinium-enhanced MR imaging of the brain: a method to reduce contrast dosage

    International Nuclear Information System (INIS)

    Chan, J.H.M.; Tsui, E.Y.K.; Chan, C.Y.; Lai, K.F.; Cheung, Y.K.; Wong, K.P.C.; Yuen, M.K.; Chau, L.F.; Fong, D.; Mok, C.K.

    2002-01-01

    The aim of the study was to investigate the feasibility of using digital subtraction in contrast-enhanced MR imaging of the brain to reduce the MR contrast dosage without jeopardizing patient care. Fifty-two patients with intracranial lesions, either intra-axial or extra-axial, detected by computerized tomography were selected for contrast-enhanced MR imaging with half-dose and full-dose of gadopentetate dimeglumine. The half-dose unsubtracted, full-dose unsubtracted, and half-dose subtracted MR images were visually assessed by counting the number of enhancing brain lesions in the images and quantitatively analyzed by computing their lesion contrast-to-background ratios (CBR). The visual conspicuity of the half-dose subtracted MR images was comparable to that of the full-dose unsubtracted MR images (p>0.05), whereas the CBR of the half-dose subtracted images was approximately two to three times higher than that of the full-dose unsubtracted images. The half-dose subtracted T1-weighted spin-echo images might be able to replace the conventional standard-dose T1-weighted spin-echo images in MR imaging of the brain. (orig.)

  1. The practical approach to the evaluation of methods used to determine the disintegration time of orally disintegrating tablets (ODTs).

    Science.gov (United States)

    Brniak, Witold; Jachowicz, Renata; Pelka, Przemyslaw

    2015-09-01

    Even that orodispersible tablets (ODTs) have been successfully used in therapy for more than 20 years, there is still no compendial method of their disintegration time evaluation other than the pharmacopoeial disintegration test conducted in 800-900 mL of distilled water. Therefore, several alternative tests more relevant to in vivo conditions were described by different researchers. The aim of this study was to compare these methods and correlate them with in vivo results. Six series of ODTs were prepared by direct compression. Their mechanical properties and disintegration times were measured with pharmacopoeial and alternative methods and compared with the in vivo results. The highest correlation with oral disintegration time was found in the case of own-construction apparatus with additional weight and the employment of the method proposed by Narazaki et al. The correlation coefficients were 0.9994 (p disintegration time determination is eligible and scientifically justified.

  2. Intestinal absorption of radiocalcium. Measurement by the oral and intraveinous activity ratio and by the inverse convolution method

    International Nuclear Information System (INIS)

    Monnier, L.; Collet, H.; Suquet, P.; Mirouze, J.

    1975-01-01

    The intestinal absorption of calcium was measured by a double isotopic labelling method, the results being obtained by a mathematical deconvolution technique. This analytical method was compared with the simple measurement of the plasma radioactivity ratio for the two isotopes administered orally and intraveinously respectively. The study covered 29 determinations. It was possible to estimate the total fractional absorption of calcium (TFACa) by calculating the average of the 47 Ca/ 45 Ca quotients measured on the 3rd and 8th hour after simultaneous administration of 45 Ca intraveinously and 47 Ca by mouth. The advantages of this method are obvious: need for only two blood samplings, simplicity of calculations which nevertheless give TFACa values comparable to those obtained by deconvolution analysis. However the only information supplied by the quotients method is the total fractional absorption, whereas inverse convolution analysis provides several interesting parameters such as the maximum absorption and the mean transit time of radiocalcium through the intestinal wall [fr

  3. Oral contraceptives induced hepatotoxicity

    OpenAIRE

    B. Akshaya Srikanth; V. Manisree

    2013-01-01

    Oral Contraceptives are the pharmacological agents used to prevent pregnancy. These are divided as the combined and progestogen methods and are administered orally, transdermally, systemically and via vaginal route. All these methods contain both oestrogen and progestogen. Vigorous usage of oral contraceptives and anabolic steroids as associated with cholestasis, vascular lesions and hepatic neoplasm. Benign hepatic neoplasms are clearly associated with oral contraceptives. In this article we...

  4. Determination of ABO blood grouping from human oral squamous epithelium by the highly sensitive immunohistochemical staining method EnVision+.

    Science.gov (United States)

    Noda, Hiroshi; Yokota, Makoto; Tatsumi, Shinji; Sugiyama, Shizuyuki

    2002-03-01

    Using the highly sensitive immunohistochemical staining method EnVision+, which employs a dextran polymer reagent for the secondary antibody, the detection of the ABH antigens was attempted in the oral squamous epithelium. This new technique uses monoclonal antibody as a primary antibody and it takes about three hours for staining. The time is much shorter than conventional absorption-elution testing or absorption-inhibition testing for the determination of ABO blood grouping. Secretor saliva samples were stained at strong intensity by the antibody, which corresponded to its blood group and anti-H. On the one hand, nonsecretor saliva samples were stained at strong intensity only by the antibody that corresponded to its blood group, and at weak intensity only by anti-H. Since human oral squamous epithelium antigens were stained specifically by this method, we can examine the ABO blood group of saliva samples and perform cytodiagnosis at the same time. Our research suggested that the EnVision+ Method is a useful technique for ABO blood grouping of saliva in forensic cases.

  5. Correction of Non-Linear Propagation Artifact in Contrast-Enhanced Ultrasound Imaging of Carotid Arteries: Methods and in Vitro Evaluation.

    Science.gov (United States)

    Yildiz, Yesna O; Eckersley, Robert J; Senior, Roxy; Lim, Adrian K P; Cosgrove, David; Tang, Meng-Xing

    2015-07-01

    Non-linear propagation of ultrasound creates artifacts in contrast-enhanced ultrasound images that significantly affect both qualitative and quantitative assessments of tissue perfusion. This article describes the development and evaluation of a new algorithm to correct for this artifact. The correction is a post-processing method that estimates and removes non-linear artifact in the contrast-specific image using the simultaneously acquired B-mode image data. The method is evaluated on carotid artery flow phantoms with large and small vessels containing microbubbles of various concentrations at different acoustic pressures. The algorithm significantly reduces non-linear artifacts while maintaining the contrast signal from bubbles to increase the contrast-to-tissue ratio by up to 11 dB. Contrast signal from a small vessel 600 μm in diameter buried in tissue artifacts before correction was recovered after the correction. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. Rehabilitating a Fossilized Pronunciation Error: the /v/ and /w/, Contrast by Using the Audio-Articulation Method in Teacher Training in Turkey

    Directory of Open Access Journals (Sweden)

    Prof. Dr. Mehmet Demirezen

    2005-10-01

    Full Text Available The aim of this article is to demonstrate the applicability of a pronunciation teachingand correction case entitled the audio-articulation method, developed by Demirezen (2003,2004, in the field of teacher training in which there is a scarcity of such methods. The audio-articulation method is a fossilized pronunciation mistake breaker, moving raising awareness of a fossilized mistake to perception via listening to oral practice. This method integratespronunciation practicing into oral communication in the context of speaking by means ofchain drills, substitution drills, repetition drills, inflection drills, replacement drills,restatement drills, completion drills, transposition drills, expansion drills, contraction drills,transformation drills, integration drills, rejoinder drills, restoration drills, question-answer drills, and language games are of great help in this respect. In addition, listen and imitatetechnique with mirroring, tracking, and echoing (shadowing, developmental approximationdrills, and explanation techniques are all practiced, repeated in form of exhortations withoutboring the students. The applications of this method and related exercises, practically appliedto experimental groups during a term of 14 weeks by Murat Hişmanoğlu (2004 in a doctoraldissertation, and it has been demonstrated that its has significant rehabilitating potentiality incorrecting the pronunciation errors of non-native speaking English language teachers andstudent teachers in Turkey.

  7. The comparison of two methods to obtain human oral keratinocytes in primary culture; Comparacao de dois metodos de obtencao celular para cultura primaria de queratinocitos bucais humanos

    Energy Technology Data Exchange (ETDEWEB)

    Klingbeil, Maria Fatima Guarizo

    2006-07-01

    The therapeutic procedures frequently used in oral treatments for the pathological diseases are surgical, resulting in failures of the mucosal continuity.The possibility to obtain transplantable oral epithelia from an in vitro cell culture opens new utilization perspectives not only to where it comes from, but also as a reconstructive material for other parts of the human body, such as: urethra, epithelia corneo-limbal, cornea, ocular surface. Many researchers still use controversial methods for obtaining cells. It was therefore evaluated and compared the efficiency in both methods: enzymatic and direct explant to obtain oral keratinocytes from human oral mucosa. Fragments of intra oral epithelial tissues from healthy human subjects, undergoing dental surgeries, were donated to the research project. The keratinocytes were cultivated over a feeder-layer from a previously irradiated 3T3 Swiss albino fibroblasts. In this study it was compared the time needed in the cell obtention, the best cell amount between both methods, the life-span, the cell capacity to form an in vitro epithelia and its morphologic structure. The results in the assessment of both methods have shown the possibility to obtain keratinocytes from a small oral fragment, but at the same time we may verify the advantages and peculiar restrictions for each one of both analyzed methods. (author)

  8. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain

    International Nuclear Information System (INIS)

    Eide, Per Kristian; Ringstad, Geir

    2015-01-01

    Recently, the “glymphatic system” of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain

  9. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain.

    Science.gov (United States)

    Eide, Per Kristian; Ringstad, Geir

    2015-11-01

    Recently, the "glymphatic system" of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain.

  10. Contrast media

    International Nuclear Information System (INIS)

    Decazes, Ph.

    2004-01-01

    The Guerbet firm, which holds 69% of the capital on the contrast media for medical imagery, could sale about 20% of this capital in order to accelerate its development in the United States, one of its next market with the Japan. (O.M.)

  11. Contrast analysis : A tutorial

    NARCIS (Netherlands)

    Haans, A.

    2018-01-01

    Contrast analysis is a relatively simple but effective statistical method for testing theoretical predictions about differences between group means against the empirical data. Despite its advantages, contrast analysis is hardly used to date, perhaps because it is not implemented in a convenient

  12. Comparison of Postprandial Lipemia between Women who are on Oral Contraceptive Methods and Those who are not

    Directory of Open Access Journals (Sweden)

    Jefferson Petto

    2014-09-01

    Full Text Available Background: Postprandial Lipemia (PPL is a physiological process that reflects the ability of the body to metabolize lipids. Even though the influence of oral contraceptives (OC on PPL is not known, it is a known fact that their use increases fasting lipid values. Objective: To compare the PPL between women who are on OC and those who are not. Methods: A prospective analytical study which assessed eutrophic women, aged between 18 and 28 years old, who were irregularly active and with fasting triglycerides ≤150 mg/dL. They were divided into two groups: oral contraceptive group (COG and non-oral contraceptive group (NCOG. Volunteers were submitted to the PPL test, in which blood samples were collected in time 0 (12-hour fasting and after the intake of lipids in times 180 and 240 minutes. In order to compare the triglyceride deltas, which reflect PPL, the two-tailed Mann-Whitney test was used for independent samples between fasting collections and 180 minutes (Δ1 and between fasting and 240 minutes (Δ2. Results: Forty women were assessed and equally divided between groups. In the fasting lipid profile, it was observed that HDL did not present significant differences and that triglycerides in COG were twice as high in comparison to NCOG. Medians of Δ1 and Δ2 presented significant differences in both comparisons (p ≤0.05. Conclusion: The results point out that women who are irregularly active and use OC present more PPL in relation to those who do not use OC, which suggests that in this population, its chronic use increases the risk of heart conditions.

  13. Solid dispersion of dutasteride using the solvent evaporation method: Approaches to improve dissolution rate and oral bioavailability in rats.

    Science.gov (United States)

    Choi, Jin-Seok; Lee, Sang-Eun; Jang, Woo Suk; Byeon, Jong Chan; Park, Jeong-Sook

    2018-09-01

    The aim of this study was to develop a dutasteride (DUT) solid dispersion (SD) using hydrophilic substances to enhance its dissolution (%) and oral bioavailability in rats. DUT-SD formulations were prepared with various co-polymers using a solvent evaporation method. The physical properties of DUT-SD formulations were confirmed using field emission scanning electron microscopy (FE-SEM), differential scanning calorimetry (DSC), powder X-ray diffraction (PXRD), and attenuated total reflectance Fourier transform infrared (ATR-FT-IR) spectroscopy. The toxicity and oral bioavailability of DUT-SD formulations were evaluated. Tocopheryl polyethylene glycol-1000-succinate (TPGS) was chosen as the solubilizer; and methylene chloride, and Aerosil® 200 or microcrystalline cellulose (MCC) were chosen as the solvent and carrier, respectively, based on a solubility test and pre-dissolution study. The dissolution levels of DUT-SD formulations were 86.3 ± 2.3% (F15) and 95.1 ± 1.9% (F16) after 1 h, which were higher than those of the commercial product, i.e., Avodart® (75.8 ± 1.5%) in 0.1 N HCl containing 1% (w/v) sodium lauryl sulfate (SLS). The F16 formulation was found to be stable, after assessing its dissolution (%) and drug content (%) for 6 months. The DUT-SD formulations resulted in relative bioavailability (BA) values of 126.4% (F15) and 132.1% (F16), which were enhanced compared to that of Avodart®. Dissolution (%) and relative BA values were both increased by hydrogen interaction between TPGS and DUT. This study might contribute to a new formulation (powder) whose oral bioavailability is greater than that of Avodart® (soft capsule), which could facilitate to the use of the SD system during the production process. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Probing problems and priorities in oral health (care) among community dwelling elderly in the Netherlands: a mixed method study

    NARCIS (Netherlands)

    Everaars, B.; Jerković-Ćosić, K.; van der Putten, G.J.; van der Heijden, G.J.M.G.

    2015-01-01

    Background: Complex dentitions and decline in adequate oral hygiene in elderly may lead to poor oral health. This may have impact on their general health, wellbeing and quality of life. With increased longevity, the problems and needs in oral health of community dwelling elderly lead to changes in

  15. Monte Carlo method for dose calculation due to oral X-rays

    International Nuclear Information System (INIS)

    Loureiro, Eduardo Cesar de Miranda

    1998-06-01

    The increasing utilization of oral X-rays, especially in youngsters and children, calls for the assessment of equivalent doses in their organs and tissues. With this purpose, a Monte Carlo code was adapted to simulate an X-ray source irradiating phantoms of the MIRD-5 type with different ages (10, 15 and 40 years old) to calculate the conversion coefficients which transform the exposure at skin to equivalent doses at several organs and tissues of interest. In order to check the computer program, simulations were performed for adult patients using the original code (ADAM.FOR developed at the GSF-Germany) and the adapted program (MCDRO.PAS). Good agreement between results obtained with both codes was observed. Irradiations of the incisive, canine and molar teeth were simulated. The conversion factors were calculated for the following organs and tissues: thyroid, active bone narrow (head and whole body), bone (facial skeleton, cranium and whole body), skin (head and whole body) and crystalline. Based on the obtained results, it follows that the younger the patient and the larger the field area, the higher the dose in assessed organs and tissues. The variation of the source-skin distance does not change the conversion coefficients. On the other hand, the increase in the voltage applied to the X-ray tube causes an increase in the calculated conversion coefficients. (author)

  16. Computer versus lecture: a comparison of two methods of teaching oral medication administration in a nursing skills laboratory.

    Science.gov (United States)

    Jeffries, P R

    2001-10-01

    The purpose of this study was to compare the effectiveness of both an interactive, multimedia CD-ROM and a traditional lecture for teaching oral medication administration to nursing students. A randomized pretest/posttest experimental design was used. Forty-two junior baccalaureate nursing students beginning their fundamentals nursing course were recruited for this study at a large university in the midwestern United States. The students ranged in age from 19 to 45. Seventy-three percent reported having average computer skills and experience, while 15% reported poor to below average skills. Two methods were compared for teaching oral medication administration--a scripted lecture with black and white overhead transparencies, in addition to an 18-minute videotape on medication administration, and an interactive, multimedia CD-ROM program, covering the same content. There were no significant (p lecture groups by education or computer skills. Results showed significant differences between the two groups in cognitive gains and student satisfaction (p = .01), with the computer group demonstrating higher student satisfaction and more cognitive gains than the lecture group. The groups were similar in their ability to demonstrate the skill correctly. Importantly, time on task using the CD-ROM was less, with 96% of the learners completing the program in 2 hours or less, compared to 3 hours of class time for the lecture group.

  17. A sensitive multi-residue method for the determination of 35 micropollutants including pharmaceuticals, iodinated contrast media and pesticides in water.

    Science.gov (United States)

    Valls-Cantenys, Carme; Scheurer, Marco; Iglesias, Mònica; Sacher, Frank; Brauch, Heinz-Jürgen; Salvadó, Victoria

    2016-09-01

    A sensitive, multi-residue method using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed to determine a representative group of 35 analytes, including corrosion inhibitors, pesticides and pharmaceuticals such as analgesic and anti-inflammatory drugs, five iodinated contrast media, β-blockers and some of their metabolites and transformation products in water samples. Few other methods are capable of determining such a broad range of contrast media together with other analytes. We studied the parameters affecting the extraction of the target analytes, including sorbent selection and extraction conditions, their chromatographic separation (mobile phase composition and column) and detection conditions using two ionisation sources: electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI). In order to correct matrix effects, a total of 20 surrogate/internal standards were used. ESI was found to have better sensitivity than APCI. Recoveries ranging from 79 to 134 % for tap water and 66 to 144 % for surface water were obtained. Intra-day precision, calculated as relative standard deviation, was below 34 % for tap water and below 21 % for surface water, groundwater and effluent wastewater. Method quantification limits (MQL) were in the low ng L(-1) range, except for the contrast agents iomeprol, amidotrizoic acid and iohexol (22, 25.5 and 17.9 ng L(-1), respectively). Finally, the method was applied to the analysis of 56 real water samples as part of the validation procedure. All of the compounds were detected in at least some of the water samples analysed. Graphical Abstract Multi-residue method for the determination of micropollutants including pharmaceuticals, iodinated contrast media and pesticides in waters by LC-MS/MS.

  18. Non-vitamin K antagonist oral anticoagulants versus warfarin for the prevention of spontaneous echo-contrast and thrombus in patients with atrial fibrillation or flutter undergoing cardioversion: A trans-esophageal echocardiography study.

    Science.gov (United States)

    Kim, Yun Gi; Choi, Jong-Il; Kim, Mi-Na; Cho, Dong-Hyuk; Oh, Suk-Kyu; Kook, Hyungdon; Park, Hee-Soon; Lee, Kwang No; Baek, Yong-Soo; Roh, Seung-Young; Shim, Jaemin; Park, Seong-Mi; Shim, Wan Joo; Kim, Young-Hoon

    2018-01-01

    Spontaneous echo-contrast (SEC) and thrombus observed in trans-esophageal echocardiography (TEE) is known as a strong surrogate marker for future risk of ischemic stroke in patients with atrial fibrillation (AF) or atrial flutter (AFL). The efficacy of non-vitamin K antagonist oral anticoagulants (NOAC) compared to warfarin to prevent SEC or thrombus in patients with AF or AFL is currently unknown. AF or AFL patients who underwent direct current cardioversion (DCCV) and pre-DCCV TEE evaluation from January 2014 to October 2016 in a single center were analyzed. The prevalence of SEC and thrombus were compared between patients who received NOAC and those who took warfarin. NOAC included direct thrombin inhibitor and factor Xa inhibitors. Among 1,050 patients who were considered for DCCV, 424 patients anticoagulated with warfarin or NOAC underwent TEE prior to DCCV. Eighty patients who were anticoagulated for less than 21 days were excluded. Finally, 344 patients were included for the analysis (180 warfarin users vs. 164 NOAC users). No significant difference in the prevalence of SEC (44.4% vs. 43.9%; p = 0.919), dense SEC (13.9% vs. 15.2%; p = 0.722), or thrombus (2.2% vs. 4.3%; p = 0.281) was observed between the warfarin group and the NOAC group. In multivariate analysis, there was no association between NOAC and risk of SEC (odds ratio [OR]: 1.4, 95% CI: 0.796-2.297, p = 0.265) or thrombus (OR: 3.4, 95% CI: 0.726-16.039, p = 0.120). In conclusion, effectiveness of NOAC is comparable to warfarin in preventing SEC and thrombus in patients with AF or AFL undergoing DCCV. However, numerical increase in the prevalence of thrombus in NOAC group warrants further evaluation.

  19. Is hepatotropic contrast enhanced MR a more effective method in differential diagnosis of hemangioma than multi-phase CT and unenhanced MR?

    Directory of Open Access Journals (Sweden)

    Markiet Karolina

    2011-04-01

    Full Text Available Abstract Background Cavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other benign focal lesions. The purpose of this study is to evaluate whether diagnostic accuracy of magnetic resonance imaging (MRI of hepatic hemangiomas, showing atypical pattern on US, improves with the use of Gd-BOPTA in comparison with contrast-enhanced multi-phase computed tomography (CT. Methods 178 consecutive patients with ambiguous hepatic masses showing atypical hyperechoic pattern on grey-scale US, underwent unenhanced and contrast-enhanced multi-phase multi-detector CT and MR (1.5T with the use of liver-specific contrast medium gadobenate dimeglumine (Gd-BOPTA. After intravenous contrast administration arterial (HAP, venous-portal (PVP, equilibrium phases (EP both in CT and MR and additionally hepatobiliary phase (HBP in MR were obtained. 398 lesions have been detected including 99 hemangiomas and 299 other lesions. Results In non-enhanced MDCT examination detection of hemangiomas was characterized by sensitivity of 76%, specificity of 90%, PPV of 71%, NPV of 92% and accuracy of 86%. Non-enhanced MR examination showed sensitivity of 98%, specificity of 99%, PPV of 99%, NPV of 99% and accuracy of 99%. After intravenous administration of contrast medium in MR the mentioned above parameters did not increase significantly. Conclusion Gd-BOPTA-enhanced MR in comparison with unenhanced MRI does not improve diagnostic accuracy in discriminating hemangiomas that show non-specific appearance in ultrasound examination. Unenhanced MR as a method of choice should directly follow US in course of diagnostic algorithm in differentiation of hemangiomas from other liver tumors.

  20. Aortic Volumetry at Contrast-Enhanced Magnetic Resonance Angiography: Feasibility as a Sensitive Method for Monitoring Bicuspid Aortic Valve Aortopathy.

    Science.gov (United States)

    Trinh, Brian; Dubin, Iram; Rahman, Ozair; Ferreira Botelho, Marcos P; Naro, Nicholas; Carr, James C; Collins, Jeremy D; Barker, Alex J

    2017-04-01

    Bicuspid aortic valve patients can develop thoracic aortic aneurysms and therefore require serial imaging to monitor aortic growth. This study investigates the reliability of contrast-enhanced magnetic resonance angiography (CEMRA) volumetry compared with 2-dimensional diameter measurements to identify thoracic aortic aneurysm growth. A retrospective, institutional review board-approved, and Health Insurance Portability and Accountability Act-compliant study was conducted on 20 bicuspid aortic valve patients (45 ± 8.9 years, 20% women) who underwent serial CEMRA with a minimum imaging follow-up of 11 months. Magnetic resonance imaging was performed at 1.5 T with electrocardiogram-gated, time-resolved CEMRA. Independent observers measured the diameter at the sinuses of Valsalva (SOVs) and mid ascending aorta (MAA) as well as ascending aorta volume between the aortic valve annulus and innominate branch. Intraobserver/interobserver coefficient of variation (COV) and intraclass correlation coefficient (ICC) were computed to assess reliability. Growth rates were calculated and assessed by Student t test (P volumetry. Three-dimensional CEMRA volumetry exhibited a larger effect when examining percentage growth, a better ICC, and a marginally lower COV. Volumetry may be more sensitive to growth and possibly less affected by error than diameter measurements.

  1. Evaluation of higher brain function by MRI. Flow measurement in the superior sagittal sinus using phase contrast method

    International Nuclear Information System (INIS)

    Ono, Mototsugu

    1997-01-01

    To assess the higher brain function, flow measurement in the superior sagittal sinus (SSS) was performed noninvasively using a phase contrast MRI in 76 patients with suspicious of impaired higher brain function including dementias (senile dementia of Alzheimer type; SDAT and multi-infarct dementia; MID), strokes, and others. Thirty-one normal controls were consisted of 18 healthy volunteers and 13 patients with tension headache whose higher brain function was proved be normal. Mean flow velocity was measured in the distal portion of the SSS adjoining to the occipital lobes and was multiplied by cross-sectional area of the SSS at the measuring point to obtain mean flow volume. For intellectual index, cross-cultural cognitive examination (CCCE) was applied to all cases excluding volunteers. Normal value of SSS flow volume measured by MRI was 6.92±0.66 ml/s. Significant differences in both SSS flow and CCCE score from normal controls were found in SDAT group, MID group, and non-dementia group. No substantial differences between SDAT group and MID group were noted in both CCCE score and SSS flow. In normal controls, there was no correlation between SSS flow and age, whereas, significant inverse correlation of SSS flow with age was found in all cases. Between CCCE score and SSS flow, there were nearly linear relationships in all cases, SDAT group, MID group, and non-dementia group. Significant but relatively poor correlation was found in normals. (K.H.)

  2. Detection method of proximal caries using line profile in digital intra-oral radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Min Ja; Choi, Sam Jin; Park, Hun Kuk [Department of Oral and Maxillofacial Radiology, School of Dentistry and Institute of Oral Biology, Kyung Hee University, Seoul (Korea, Republic of); Park, Jeong Hoon [Department of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2009-12-15

    The purpose of this study was to investigate how to detect proximal caries using line profile and validate linear measurements of proximal caries lesions by basic digital manipulation of radiographic images. The X-ray images of control group (15) and caries teeth (15) from patients were used. For each image, the line profile at the proximal caries-susceptible zone was calculated. To evaluate the contrast as a function of line profile to detect proximal caries, a difference coefficient (D) that indicates the relative difference between caries and sound dentin or intact enamel was measured. Mean values of D were 0.0354 {+-} 0.0155 in non-caries and 0.2632 {+-} 0.0982 in caries (p<0.001). The mean values of caries group were higher than non-caries group and there was correlation between proximal dental caries and D. It is demonstrated that the mean value of D from caries group was higher than that of control group. From the result, values of D possess great potentiality as a new detection parameter for proximal dental caries.

  3. Detection method of proximal caries using line profile in digital intra-oral radiography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Min Ja; Choi, Sam Jin; Park, Hun Kuk; Park, Jeong Hoon

    2009-01-01

    The purpose of this study was to investigate how to detect proximal caries using line profile and validate linear measurements of proximal caries lesions by basic digital manipulation of radiographic images. The X-ray images of control group (15) and caries teeth (15) from patients were used. For each image, the line profile at the proximal caries-susceptible zone was calculated. To evaluate the contrast as a function of line profile to detect proximal caries, a difference coefficient (D) that indicates the relative difference between caries and sound dentin or intact enamel was measured. Mean values of D were 0.0354 ± 0.0155 in non-caries and 0.2632 ± 0.0982 in caries (p<0.001). The mean values of caries group were higher than non-caries group and there was correlation between proximal dental caries and D. It is demonstrated that the mean value of D from caries group was higher than that of control group. From the result, values of D possess great potentiality as a new detection parameter for proximal dental caries.

  4. Comparison of caries detection methods using varying numbers of intra-oral digital photographs with visual examination for epidemiology in children

    Science.gov (United States)

    2013-01-01

    Background This was a method comparison study. The aim of study was to compare caries information obtained from a full mouth visual examination using the method developed by the British Association for the Study of Community Dentistry (BASCD) for epidemiological surveys with caries data obtained from eight, six and four intra-oral digital photographs of index teeth in two groups of children aged 5 years and 10/11 years. Methods Five trained and calibrated examiners visually examined the whole mouth of 240 5-year-olds and 250 10-/11-year-olds using the BASCD method. The children also had intra-oral digital photographs taken of index teeth. The same 5 examiners assessed the intra-oral digital photographs (in groups of 8, 6 and 4 intra-oral photographs) for caries using the BASCD criteria; dmft/DMFT were used to compute Weighted Kappa Statistic as a measure of intra-examiner reliability and intra-class correlation coefficients as a measure of inter-examiner reliability for each method. A method comparison analysis was performed to determine the 95% limits of agreement for all five examiners, comparing the visual examination method with the photographic assessment method using 8, 6 and 4 intra-oral photographs. Results The intra-rater reliability for the visual examinations ranged from 0.81 to 0.94 in the 5-year-olds and 0.90 to 0.97 in the 10-/11-year-olds. Those for the photographic assessments in the 5-year-olds were for 8 intra-oral photographs, 0.86 to 0.94, for 6 intra-oral photographs, 0.85 to 0.98 and for 4 intra-oral photographs, 0.80 to 0.96; for the 10-/11-year-olds were for 8 intra-oral photographs 0.84 to 1.00, for 6 intra-oral photographs 0.82 to 1.00 and for 4 intra-oral photographs 0.72 to 0.98. The 95% limits of agreement were −1.997 to 1.967, -2.375 to 2.735 and −2.250 to 2.921 respectively for the 5-year-olds and −2.614 to 2.027, -2.179 to 3.887 and −2.594 to 2.163 respectively for the 10-/11-year-olds. Conclusions The photographic

  5. The Fifth German Oral Health Study (Fünfte Deutsche Mundgesundheitsstudie, DMS V) - rationale, design, and methods.

    Science.gov (United States)

    Jordan, Rainer A; Bodechtel, Constanze; Hertrampf, Katrin; Hoffmann, Thomas; Kocher, Thomas; Nitschke, Ina; Schiffner, Ulrich; Stark, Helmut; Zimmer, Stefan; Micheelis, Wolfgang

    2014-12-29

    Oral diseases rank among the most prevalent non-communicable diseases in modern societies. In Germany, oral epidemiological data show that both dental caries and periodontal diseases are highly prevalent, though significant improvements in oral health has been taking in the population within the last decades, particularly in children. It is, therefore, the aim of the Fifth German Oral Health Study (DMS V) to actualize the data on current oral health status and to gather information on oral health behavior and risk factors. In addition to current oral health monitoring, the study will also permit conclusions about trends in the development of oral health in Germany between 1989 and 2014. DMS V is a cross-sectional, multi-center, nationwide representative, socio-epidemiological study to investigate the oral health status und behavior of the German resident population in four age cohorts. Study participants are children (12-year-olds), adults (35- to 44-year-olds), young olds (65- to 74-year-olds), and old olds (75- to 100-year-olds) who are drawn from local residents' registration offices. Social-science investigation parameters concern subjective perceptions and attitudes regarding oral health and nutrition, sense of coherence, and socio-demographic data. Clinical oral parameters are tooth loss, caries and periodontitis, prosthodontic status, further developmental and acquired dental hard tissue and mucosal lesions. To ensure reproducibility, the dental investigators are trained and calibrated by experts and multiple reliability checks are performed throughout the field phase. Statistical analyses are calculated according to a detailed statistical analysis plan. The DMS studies first performed in 1989, 1992 and repeated in 1997 and 2005 are the only cross-sectional oral health studies conducted in Germany on a population-based national representative level. Updated prevalence and trend analyses of key oral diseases are, therefore, of major epidemiological and health

  6. Dynamic contrast-enhanced 3-T magnetic resonance imaging: a method for quantifying disease activity in early polyarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Navalho, Marcio [Faculdade de Medicina da Universidade de Lisboa, Rheumatology Research Unit, Instituto de Medicina Molecular, Lisbon (Portugal); Hospital da Luz, Radiology Department, Lisbon (Portugal); Hospital da Luz, Centro de Imagiologia, Lisbon (Portugal); Resende, Catarina [Hospital da Luz, Rheumatology Department, Lisbon (Portugal); Hospital de Santa Maria, Rheumatology Department, Centro Hospitalar de Lisboa Norte, EPE, Lisbon (Portugal); Rodrigues, Ana Maria; Fonseca, Joao Eurico; Canhao, Helena [Faculdade de Medicina da Universidade de Lisboa, Rheumatology Research Unit, Instituto de Medicina Molecular, Lisbon (Portugal); Hospital de Santa Maria, Rheumatology Department, Centro Hospitalar de Lisboa Norte, EPE, Lisbon (Portugal); Gaspar, Augusto [Hospital da Luz, Radiology Department, Lisbon (Portugal); Campos, Jorge [Hospital de Santa Maria, Radiology Department, Centro Hospitalar de Lisboa Norte, EPE, Lisbon (Portugal)

    2012-01-15

    To determine whether measurement of synovial enhancement and thickness quantification parameters with 3.0-Tesla magnetic resonance imaging (3-T MRI) can reliably quantify disease activity in patients with early polyarthritis. Eighteen patients (16 women, 2 men; mean age 46 years) with early polyarthritis with less than 12 months of symptoms were included. MRI examination using 3-T device was performed by a new approach including both wrists and hands simultaneously in the examination field-of-view. MRI scoring of disease activity included quantification of synovial enhancement with simple measurements such as rate of early enhancement (REE; REE{sub 57} = S{sub 57}/S{sub 200}, where S{sub 57} and S{sub 200} are the signal intensities 57 s and 200 s after gadolinium injection) and rate of relative enhancement (RE; RE = S{sub 200} - S{sub 0}). Both wrists and hands were scored according to the Rheumatoid Arthritis MRI Scoring System (RAMRIS) for synovitis. Disease activity was clinically assessed by the 28-joint Disease Activity Score (DAS28). DAS28 score was strongly correlated with RE (r = 0.8331, p < 0.0001), REE (r = 0.8112, p < 0.0001), and RAMRIS score for synovitis (r = 0.7659, p < 0.0002). An REE score above 0.778 accurately identified patients with clinically active disease (sensitivity 92%; specificity 67%; p < 0.05). A statistically significant difference was observed in the RE, REE, and RAMRIS scores for synovitis between patients with active and inactive disease (p < 0.05). Our findings support the use of 3-T dynamic contrast-enhanced MRI for precise quantification of disease activity and for discriminating active disease from inactive disease in early polyarthritis. (orig.)

  7. [Formulation optimization of panax notoginsenoside orally fast disintegration tablets].

    Science.gov (United States)

    Wang, Zhi; Wei, Li; Chen, Ting

    2008-07-01

    To optimize the formulation of panax notoginsenoside orally fast disintegrating tablets. Mannitol, microcrystalline cellulose (PH 102) and lactose 80 were used as diluent. A polynomial regression algorithm was used to evaluate the relationship between the controlling factor, compacting pressure and diluent ratio, and disintegration time, tensile strength of tablets. Optimum formulation and process parameters could be determined by contrast the contour plot of tensile strength to that of disintegration time. The disintegration time and tensile strength of panax notoginsenoside oral disintegrating tablets were good, and the taste was satisfactory. Panax notoginsenoside oral disintegrating tablets achieve the goal of design and this method can be fairly used in formulation screening.

  8. Comparison of two methods for estimating the abundance, diversity and habitat preference of fluvial macroinvertebrates in contrasting habitats

    NARCIS (Netherlands)

    Alonso, A.; Camargo, J.A.

    2010-01-01

    In this research we evaluate the effects of the method used for estimating the potential surface available for benthic macroinvertebrates in macrophyte and unvegetated habitats on several metrics and habitat preference of aquatic macroinvertebrates in the upper catchment of the Henares River

  9. Data on consistency among different methods to assess atherosclerotic plaque echogenicity on standard ultrasound and intraplaque neovascularization on contrast-enhanced ultrasound imaging in human carotid artery

    Directory of Open Access Journals (Sweden)

    Mattia Cattaneo

    2016-12-01

    Full Text Available Here we provide the correlation among different carotid ultrasound (US variables to assess echogenicity n standard carotid US and to assess intraplaque neovascularization on contrast enhanced US. We recruited 45 consecutive subjects with an asymptomatic≥50% carotid artery stenosis. Carotid plaque echogenicity at standard US was visually graded according to Gray–Weale classification (GW and measured by the greyscale median (GSM, a semi-automated computerized measurement performed by Adobe Photoshop®. On CEUS imaging IPNV was graded according to the visual appearance of contrast within the plaque according to three different methods: CEUS_A (1=absent; 2=present; CEUS_B a three-point scale (increasing IPNV from 1 to 3; CEUS_C a four-point scale (increasing IPNV from 0 to 3. We have also implemented a new simple quantification method derived from region of interest (ROI signal intensity ratio as assessed by QLAB software. Further information is available in “Contrast-enhanced ultrasound imaging of intraplaque neovascularization and its correlation to plaque echogenicity in human carotid arteries atherosclerosis (M. Cattaneo, D. Staub, A.P. Porretta, J.M. Gallino, P. Santini, C. Limoni et al., 2016 [1].

  10. Method validation for determination of gadolinium (III) and diethyl tetraamine pentaacetic acid (DTPA) ligand amount determination in Gd-DTPA contrast agent

    International Nuclear Information System (INIS)

    Rien Ritawidya; Martalena Ramli; Cecep Taufik Rustendi

    2014-01-01

    Gd-DTPA is one of the contrast agent which is important in Magnetic Resonance Imaging (MRI) application. The presence of free Gd (III) ion and free DTPA ligand is extremely toxic in human body. Therefore, it needs a method in order to determine free ion Gd (III) and free DTPA ligand concentration which then MRI would be applicable for clinical purpose. The analytical method that selected for the research was complexometric titration. The research was carried out in order to make validation method of free ion Gd (III) and free DTPA ligand determination, then validation criteria such as % recovery, % coefisien of variance and linearity could be obtained. Some experiments that had been done on determination of free Gd (III) with DTPA resulted in % recovery between 30,33% - 183,59%, the precision from %CV between 2,34% - 35,25% and linearity showed with value of R = 0,9525. Meanwhile on determination of DTPA with Gd (III) resulted in % recovery between 105.15% - 139,12%, %CV between 6,78% - 10,96% and R = 0,9525. Validation result indicates that determination method can not be used as a method to determine free ion Gd(III) and free DTPA ligand in contrast agent. (author)

  11. A contrast enhancement and scanning techniques for CT angiography of head and neck. One phase injection method for simultaneous imaging of vessels and tumor

    International Nuclear Information System (INIS)

    Morita, Yasuhiko; Indo, Hiroko; Noikura, Takenori

    1999-01-01

    We report on a method of CT-Angiography useful for examining lesion of the head and neck using three-dimensional images and measured CT value. This study focused on some of the important blood vessels in the head and neck. The aim of this method was to obtain high-contrast enhancement for both vessels and tumors at same time. A total amount of 100 ml nonionic contrast media (Omnipaque 240, 240 mg iodine per milliliter, Daiichi seiyaku, Tokyo, Japan) was injected intravenously with a flow of 1.5 ml/sec. Spiral scans, 24 rotations with 24 seconds, were started at a time when remaining amount of contrast media had become 30 to 20 ml. All CT scans were performed using double speed spiral scan technique with a slice thickness of 2 to 3 mm and table speeds from 3 to 5 mm/rotation. The patients populations consisted of 9 men and 6 women who ranged in age from 37 to 85 years. Sixteen CT-angiography were performed according to this method. Mean CT values of major blood vessels were measured in order to find out threshold at the level of submandibular gland in 13 examinations for 12 subjects. Important vessels like the common, internal, and the external artery, internal and external jugular vein were clearly visible in all subjects. Three dimensional images of these vessels could also be reconstructed for 15 of the subjects. Mean CT values were 211 Hounsfield units (HU) and 209 HU for the right and left internal carotid artery, respectively, and 204 HU and 206 HU for the right and left external carotid artery, respectively. Mean CT values for right and left internal jugular vein were 195 HU and 194 HU respectively. Measured CT values at each important blood vessels showed this method could yields acceptable enhancements. Good enhancement effect of tumor and blood vessels in the same scan seems to be mutually incompatible. One very important trade-off is the early enhancement effect at blood vessels versus the late enhancement effect at tumors. The other important trade

  12. An automatic respiratory gating method for the improvement of microcirculation evaluation: application to contrast-enhanced ultrasound studies of focal liver lesions

    Energy Technology Data Exchange (ETDEWEB)

    Mule, S; Kachenoura, N; Lucidarme, O; De Oliveira, A; Pellot-Barakat, C; Herment, A; Frouin, F, E-mail: Sebastien.Mule@gmail.com [INSERM UMR-S 678, 75634 Paris Cedex 13 (France)

    2011-08-21

    Contrast-enhanced ultrasound (CEUS), with the recent development of both contrast-specific imaging modalities and microbubble-based contrast agents, allows noninvasive quantification of microcirculation in vivo. Nevertheless, functional parameters obtained by modeling contrast uptake kinetics could be impaired by respiratory motion. Accordingly, we developed an automatic respiratory gating method and tested it on 35 CEUS hepatic datasets with focal lesions. Each dataset included fundamental mode and cadence contrast pulse sequencing (CPS) mode sequences acquired simultaneously. The developed method consisted in (1) the estimation of the respiratory kinetics as a linear combination of the first components provided by a principal components analysis constrained by a prior knowledge on the respiratory rate in the frequency domain, (2) the automated generation of two respiratory-gated subsequences from the CPS mode sequence by detecting end-of-inspiration and end-of-expiration phases from the respiratory kinetics. The fundamental mode enabled a more reliable estimation of the respiratory kinetics than the CPS mode. The k-means algorithm was applied on both the original CPS mode sequences and the respiratory-gated subsequences resulting in clustering maps and associated mean kinetics. Our respiratory gating process allowed better superimposition of manually drawn lesion contours on k-means clustering maps as well as substantial improvement of the quality of contrast uptake kinetics. While the quality of maps and kinetics was satisfactory in only 11/35 datasets before gating, it was satisfactory in 34/35 datasets after gating. Moreover, noise amplitude estimated within the delineated lesions was reduced from 62 {+-} 21 to 40 {+-} 10 (p < 0.01) after gating. These findings were supported by the low residual horizontal (0.44 {+-} 0.29 mm) and vertical (0.15 {+-} 0.16 mm) shifts found during manual motion correction of each respiratory-gated subsequence. The developed

  13. Essentials of oral cancer.

    Science.gov (United States)

    Rivera, César

    2015-01-01

    Oral cancer is one of the 10 most common cancers in the world, with a delayed clinical detection, poor prognosis, without specific biomarkers for the disease and expensive therapeutic alternatives. This review aims to present the fundamental aspects of this cancer, focused on squamous cell carcinoma of the oral cavity (OSCC), moving from its definition and epidemiological aspects, addressing the oral carcinogenesis, oral potentially malignant disorders, epithelial precursor lesions and experimental methods for its study, therapies and future challenges. Oral cancer is a preventable disease, risk factors and natural history is already being known, where biomedical sciences and dentistry in particular are likely to improve their poor clinical indicators.

  14. Perceptions of Teaching Methods for Preclinical Oral Surgery: A Comparison with Learning Styles

    OpenAIRE

    Omar, Esam

    2017-01-01

    Purpose: Dental extraction is a routine part of clinical dental practice. For this reason, understanding the way how students? extraction knowledge and skills development are important. Problem Statement and Objectives: To date, there is no accredited statement about the most effective method for the teaching of exodontia to dental students. Students have different abilities and preferences regarding how they learn and process information. This is defined as learning style. In this study, the...

  15. Oral calcitonin

    Directory of Open Access Journals (Sweden)

    Hamdy RC

    2012-09-01

    Full Text Available Ronald C Hamdy,1,2 Dane N Daley11Osteoporosis Center, College of Medicine, East Tennessee State University, 2Veterans Affairs Medical Center, Johnson City, TN, USAAbstract: Calcitonin is a hormone secreted by the C-cells of the thyroid gland in response to elevations of the plasma calcium level. It reduces bone resorption by inhibiting mature active osteoclasts and increases renal calcium excretion. It is used in the management of postmenopausal osteoporosis, Paget's disease of bone, and malignancy-associated hypercalcemia. Synthetic and recombinant calcitonin preparations are available; both have similar pharmacokinetic and pharmacodynamic profiles. As calcitonin is a peptide, the traditional method of administration has been parenteral or intranasal. This hinders its clinical use: adherence with therapy is notoriously low, and withdrawal from clinical trials has been problematic. An oral formulation would be more attractive, practical, and convenient to patients. In addition to its effect on active osteoclasts and renal tubules, calcitonin has an analgesic action, possibly mediated through β-endorphins and the central modulation of pain perception. It also exerts a protective action on cartilage and may be useful in the management of osteoarthritis and possibly rheumatoid arthritis. Oral formulations of calcitonin have been developed using different techniques. The most studied involves drug-delivery carriers such as Eligen® 8-(N-2hydroxy-5-chloro-benzoyl-amino-caprylic acid (5-CNAC (Emisphere Technologies, Cedar Knolls, NJ. Several factors affect the bioavailability and efficacy of orally administered calcitonin, including amount of water used to take the tablet, time of day the tablet is taken, and proximity to intake of a meal. Preliminary results looked promising. Unfortunately, in two Phase III studies, oral calcitonin (0.8 mg with 200 mg 5-CNAC, once a day for postmenopausal osteoporosis and twice a day for osteoarthritis failed to

  16. Oral histories: a simple method of assigning chronological age to isotopic values from human dentine collagen.

    Science.gov (United States)

    Beaumont, Julia; Montgomery, Janet

    2015-01-01

    Stable isotope ratios of carbon (δ(13)C) and nitrogen (δ(15)N) in bone and dentine collagen have been used for over 30 years to estimate palaeodiet, subsistence strategy, breastfeeding duration and migration within burial populations. Recent developments in dentine microsampling allow improved temporal resolution for dietary patterns. A simple method is proposed which could be applied to human teeth to estimate chronological age represented by dentine microsamples in the direction of tooth growth, allowing comparison of dietary patterns between individuals and populations. The method is tested using profiles from permanent and deciduous teeth of two individuals. Using a diagrammatic representation of dentine development by approximate age for each human tooth (based on the Queen Mary University of London Atlas), this study estimated the age represented by each dentine section. Two case studies are shown: comparison of M1 and M2 from a 19th century individual from London, England, and identification of an unknown tooth from an Iron Age female adult from Scotland. The isotopic profiles demonstrate that variations in consecutively-forming teeth can be aligned using this method to extend the dietary history of an individual or identify an unknown tooth by matching the profiles.

  17. Generalized Phase Contrast

    CERN Document Server

    Glückstad, Jesper

    2009-01-01

    Generalized Phase Contrast elevates the phase contrast technique not only to improve phase imaging but also to cross over and interface with diverse and seemingly disparate fields of contemporary optics and photonics. This book presents a comprehensive introduction to the Generalized Phase Contrast (GPC) method including an overview of the range of current and potential applications of GPC in wavefront sensing and phase imaging, structured laser illumination and image projection, optical trapping and manipulation, and optical encryption and decryption. The GPC method goes further than the restrictive assumptions of conventional Zernike phase contrast analysis and achieves an expanded range of validity beyond weak phase perturbations. The generalized analysis yields design criteria for tuning experimental parameters to achieve optimal performance in terms of accuracy, fidelity and light efficiency. Optimization can address practical issues, such as finding an optimal spatial filter for the chosen application, ...

  18. Non-contrast-enhanced hepatic MR angiography: Do two-dimensional parallel imaging and short tau inversion recovery methods shorten acquisition time without image quality deterioration?

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, Kotaro, E-mail: kotaro@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Isoda, Hiroyoshi, E-mail: sayuki@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Okada, Tomohisa, E-mail: tomokada@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Kamae, Toshikazu, E-mail: toshi13@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Arizono, Shigeki, E-mail: arizono@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Hirokawa, Yuusuke, E-mail: yuusuke@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Shibata, Toshiya, E-mail: ksj@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Togashi, Kaori, E-mail: ktogashi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan)

    2011-01-15

    Objective: To study whether shortening the acquisition time for selective hepatic artery visualization is feasible without image quality deterioration by adopting two-dimensional (2D) parallel imaging (PI) and short tau inversion recovery (STIR) methods. Materials and methods: Twenty-four healthy volunteers were enrolled. 3D true steady-state free-precession imaging with a time spatial labeling inversion pulse was conducted using 1D or 2D-PI and fat suppression by chemical shift selective (CHESS) or STIR methods. Three groups of different scan conditions were assigned and compared: group A (1D-PI factor 2 and CHESS), group B (2D-PI factor 2 x 2 and CHESS), and group C (2D-PI factor 2 x 2 and STIR). The artery-to-liver contrast was quantified, and the quality of artery visualization and overall image quality were scored. Results: The mean scan time was 9.5 {+-} 1.0 min (mean {+-} standard deviation), 5.9 {+-} 0.8 min, and 5.8 {+-} 0.5 min in groups A, B, and C, respectively, and was significantly shorter in groups B and C than in group A (P < 0.01). The artery-to-liver contrast was significantly better in group C than in groups A and B (P < 0.01). The scores for artery visualization and overall image quality were worse in group B than in groups A and C. The differences were statistically significant (P < 0.05) regarding the arterial branches of segments 4 and 8. Between group A and group C, which had similar scores, there were no statistically significant differences. Conclusion: Shortening the acquisition time for selective hepatic artery visualization was feasible without deterioration of the image quality by the combination of 2D-PI and STIR methods. It will facilitate using non-contrast-enhanced MRA in clinical practice.

  19. Non-contrast-enhanced hepatic MR angiography: Do two-dimensional parallel imaging and short tau inversion recovery methods shorten acquisition time without image quality deterioration?

    International Nuclear Information System (INIS)

    Shimada, Kotaro; Isoda, Hiroyoshi; Okada, Tomohisa; Kamae, Toshikazu; Arizono, Shigeki; Hirokawa, Yuusuke; Shibata, Toshiya; Togashi, Kaori

    2011-01-01

    Objective: To study whether shortening the acquisition time for selective hepatic artery visualization is feasible without image quality deterioration by adopting two-dimensional (2D) parallel imaging (PI) and short tau inversion recovery (STIR) methods. Materials and methods: Twenty-four healthy volunteers were enrolled. 3D true steady-state free-precession imaging with a time spatial labeling inversion pulse was conducted using 1D or 2D-PI and fat suppression by chemical shift selective (CHESS) or STIR methods. Three groups of different scan conditions were assigned and compared: group A (1D-PI factor 2 and CHESS), group B (2D-PI factor 2 x 2 and CHESS), and group C (2D-PI factor 2 x 2 and STIR). The artery-to-liver contrast was quantified, and the quality of artery visualization and overall image quality were scored. Results: The mean scan time was 9.5 ± 1.0 min (mean ± standard deviation), 5.9 ± 0.8 min, and 5.8 ± 0.5 min in groups A, B, and C, respectively, and was significantly shorter in groups B and C than in group A (P < 0.01). The artery-to-liver contrast was significantly better in group C than in groups A and B (P < 0.01). The scores for artery visualization and overall image quality were worse in group B than in groups A and C. The differences were statistically significant (P < 0.05) regarding the arterial branches of segments 4 and 8. Between group A and group C, which had similar scores, there were no statistically significant differences. Conclusion: Shortening the acquisition time for selective hepatic artery visualization was feasible without deterioration of the image quality by the combination of 2D-PI and STIR methods. It will facilitate using non-contrast-enhanced MRA in clinical practice.

  20. A contrast between DEMATEL-ANP and ANP methods for six sigma project selection: a case study in healthcare industry.

    Science.gov (United States)

    Ortíz, Miguel A; Felizzola, Heriberto A; Nieto Isaza, Santiago

    2015-01-01

    The project selection process is a crucial step for healthcare organizations at the moment of implementing six sigma programs in both administrative and caring processes. However, six-sigma project selection is often defined as a decision making process with interaction and feedback between criteria; so that it is necessary to explore different methods to help healthcare companies to determine the Six-sigma projects that provide the maximum benefits. This paper describes the application of both ANP (Analytic Network process) and DEMATEL (Decision Making trial and evaluation laboratory)-ANP in a public medical centre to establish the most suitable six sigma project and finally, these methods were compared to evaluate their performance in the decision making process. ANP and DEMATEL-ANP were used to evaluate 6 six sigma project alternatives under an evaluation model composed by 3 strategies, 4 criteria and 15 sub-criteria. Judgement matrixes were completed by the six sigma team whose participants worked in different departments of the medical centre. The improving of care opportunity in obstetric outpatients was elected as the most suitable six sigma project with a score of 0,117 as contribution to the organization goals. DEMATEL-ANP performed better at decision making process since it reduced the error probability due to interactions and feedback. ANP and DEMATEL-ANP effectively supported six sigma project selection processes, helping to create a complete framework that guarantees the prioritization of projects that provide maximum benefits to healthcare organizations. As DEMATEL- ANP performed better, it should be used by practitioners involved in decisions related to the implementation of six sigma programs in healthcare sector accompanied by the adequate identification of the evaluation criteria that support the decision making model. Thus, this comparative study contributes to choosing more effective approaches in this field. Suggestions of further work are also

  1. Acute influence of the application of strength treatment based on the combinated contrast training method on precision and velocity in overarm handball throwing

    Directory of Open Access Journals (Sweden)

    Juan S. Gómez Navarrete

    2011-01-01

    Full Text Available Abstract Combination of strengh training methods has been shown as an effective way for strengh development. This is specially indicated for improving explosive strengh and power. Our study shows the influence of combined contrast improvement method on overarm throwing in handball. Treatment consisted on one session of combined contras method. 10 handball palyers and 13 non-players participated in this estudy. The instrumental was a gun radar to know velocity throws, a camera to digitalize the accuracy, and an isometric dynamometer for strenght data collection. Results show a significant decrease in peak of force values in players group. Another significant decrease was obsesrved on integral to peak force for both groups. There are significant positive relations between throwing velocity parameters related to weight and size with isometric peak of force. We concluded that isometric time/strengh curve is an usefull instrument to observe changes produced in the subjet's capacity of producing strengh during training. Keywords: Precision, velocity, overarm handball throwing, isometric test, combined contrast method

  2. Methods of contrast variation by nuclear polarisation in small-angle neutron scattering: Observation of domains of nuclear polarisation by neutron scattering

    International Nuclear Information System (INIS)

    Leymarie, E.

    2002-11-01

    In this thesis we study the theoretical and experimental aspects of Contrast Variation by Nuclear Polarization (CVNP) applied to small-angle neutron scattering. The basics of neutron scattering theory is developed by highlighting the origin of the CVNP method: the strong spin dependence of thermal neutron scattering, especially on protons. We also present the principles of NMR with a special attention on the method of dynamic nuclear polarization by the solid effect which makes it possible to control the proton polarization and therefore the contrast for neutron scattering. We present a theoretical study of the CVNP method called static which supposes that the nuclear polarization is homogeneous in the sample and constant during the experiment. We show that it allows one to obtain partial structure functions of systems with multiple components, by carrying out several acquisitions with different polarizations on a single sample. For this purpose, we tested a simple device to stabilize the nuclear polarization. We describe finally a new application of the CVNP method called dynamic. In a solution of deuterated glycerol-water containing a small concentration of paramagnetic centres, we showed the existence of domains of polarized protons at the onset of dynamic polarization. This reinforces considerably the coherent scattering of paramagnetic centres. We describe the theoretical reasons explaining the appearance of these domains of polarization, as well as the various techniques used to observe them by neutron scattering. (author)

  3. Oral Cancer

    Science.gov (United States)

    Oral cancer can form in any part of the mouth. Most oral cancers begin in the flat cells that cover the ... your mouth, tongue, and lips. Anyone can get oral cancer, but the risk is higher if you are ...

  4. Sound radiation contrast in MR phase images. Method for the representation of elasticity, sound damping, and sound impedance changes

    International Nuclear Information System (INIS)

    Radicke, Marcus

    2009-01-01

    The method presented in this thesis combines ultrasound techniques with the magnetic-resonance tomography (MRT). An ultrasonic wave generates in absorbing media a static force in sound-propagation direction. The force leads at sound intensities of some W/cm 2 and a sound frequency in the lower MHz range to a tissue shift in the micrometer range. This tissue shift depends on the sound power, the sound frequency, the sound absorption, and the elastic properties of the tissue. A MRT sequence of the Siemens Healthcare AG was modified so that it measures (indirectly) the tissue shift, codes as grey values, and presents as 2D picture. By means of the grey values the sound-beam slope in the tissue can be visualized, and so additionally sound obstacles (changes of the sound impedance) can be detected. By the MRT images token up spatial changes of the tissue parameters sound absorption and elasticity can be detected. In this thesis measurements are presented, which show the feasibility and future chances of this method especially for the mammary-cancer diagnostics. [de

  5. Comparative evaluation of positive contrast and double contrast gastrography in dogs

    International Nuclear Information System (INIS)

    Dileepkumar, K.M.; Rajankutty, K.; Sarada, Amma T.; Devanand, C.B.; Vijayan, N.

    2012-01-01

    A contrast radiography of stomach with oral barium sulphate suspension 25% (5 mL/kg b.wt positive contrast) and double contrast with oral barium sulphate 25% (3 mL/kg b.wt) followed by air (2 to 10 mL/kg b.wt, negative contrast) was done on six dogs to study the affections of stomach. Contrast radiography using barium sulphate alone was found satisfactory to identify most of the lesions of the stomach. Double contrast radiography using barium sulphate and air, required sedation to control the animals for proper administration. For the diagnosis of mucosal lesions, double contrast radiography was better than barium sulphate alone. Key words: Barium, Contrast radiography, Dog, Double contrast, Stomach

  6. Alternative methods for the median lethal dose (LD(50)) test: the up-and-down procedure for acute oral toxicity.

    Science.gov (United States)

    Rispin, Amy; Farrar, David; Margosches, Elizabeth; Gupta, Kailash; Stitzel, Katherine; Carr, Gregory; Greene, Michael; Meyer, William; McCall, Deborah

    2002-01-01

    The authors have developed an improved version of the up-and-down procedure (UDP) as one of the replacements for the traditional acute oral toxicity test formerly used by the Organisation for Economic Co-operation and Development member nations to characterize industrial chemicals, pesticides, and their mixtures. This method improves the performance of acute testing for applications that use the median lethal dose (classic LD50) test while achieving significant reductions in animal use. It uses sequential dosing, together with sophisticated computer-assisted computational methods during the execution and calculation phases of the test. Staircase design, a form of sequential test design, can be applied to acute toxicity testing with its binary experimental endpoints (yes/no outcomes). The improved UDP provides a point estimate of the LD50 and approximate confidence intervals in addition to observed toxic signs for the substance tested. It does not provide information about the dose-response curve. Computer simulation was used to test performance of the UDP without the need for additional laboratory validation.

  7. Determinants of Oral Health: Does Oral Health Literacy Matter?

    OpenAIRE

    Naghibi Sistani, Mohammad Mehdi; Yazdani, Reza; Virtanen, Jorma; Pakdaman, Afsaneh; Murtomaa, Heikki

    2013-01-01

    Objective. To evaluate oral health literacy, independent of other oral health determinants, as a risk indicator for self-reported oral health. Methods. A cross-sectional population-based survey conducted in Tehran, Iran. Multiple logistic regression analysis served to estimate the predictive effect of oral health literacy on self-reported oral health status (good versus poor) controlling for socioeconomic and demographic factors and tooth-brushing behavior. Results. In all, among 1031 partici...

  8. Study of optimal flip angle for inversion-recovery gradient echo method in delayed contrast-enhanced cardiac magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ogawa, Masashi; Matsumura, Yoshio; Tsuchihashi, Toshio

    2013-01-01

    Delayed contrast-enhanced cardiac magnetic resonance imaging (MRI) is a valuable tool for detecting myocardial infarction and assessing myocardial viability. The standard viability MRI technique is the inversion-recovery gradient echo (IR-GRE) method. Several previous studies have demonstrated that this imaging technique provides superior image quality at high magnetic field strengths, e.g., 3.0 T. However, there are numerous possible flip angles. We investigated the optimal flip angle of IR-GRE in delayed contrast-enhanced cardiac MRI. Phantoms were made that modeled infarcted myocardium and normal myocardium after administration of contrast agent. To determine optimal flip angle, we compared the contrast-to-noise ratio (CNR) among these phantoms and evaluated the degree of artifacts induced by increased flip angle. The flip angle that showed the highest CNR for 2D IR-GRE and 3D IR-GRE was 30deg/15deg at 1.5 T and 25deg/15deg at 3.0 T. The flip angle that showed the highest CNR was independent of R-R interval. Streak artifacts induced by increased flip angle tended to occur more readily at 3.0 T than 1.5 T. The optimal flip angle for 2D IR-GRE and 3D IR-GRE at 1.5 T was 30deg and 15deg, respectively. At 3.0 T, taking into account the results for both CNR and streak artifacts, we concluded the optimal flip angle of 2D IR-GRE to be 15-20deg. (author)

  9. Screening for oral cancer.

    Science.gov (United States)

    Jitender, Solanki; Sarika, Gupta; Varada, Hiremath R; Omprakash, Yadav; Mohsin, Khan

    2016-11-01

    Oral cancer is considered as a serious health problem resulting in high morbidity and mortality. Early detection and prevention play a key role in controlling the burden of oral cancer worldwide. The five-year survival rate of oral cancer still remains low and delayed diagnosis is considered as one of the major reasons. This increases the demand for oral screening. Currently, screening of oral cancer is largely based on visual examination. Various evidence strongly suggest the validity of visual inspection in reducing mortality in patients at risk for oral cancer. Simple visual examination is accompanied with adjunctive techniques for subjective interpretation of dysplastic changes. These include toluidine blue staining, brush biopsy, chemiluminescence and tissue autofluorescence. This review highlights the efficacy of various diagnostic methods in screening of oral cancer. © 2016 Old City Publishing, Inc.

  10. Dynamic magnetic resonance imaging of cervical lymph nodes in patients with oral cancer. Utility of the small region of interest method in evaluating the architecture of cervical lymph nodes

    International Nuclear Information System (INIS)

    Oomori, Miwako; Fukunari, Fumiko; Kagawa, Toyohiro; Okamura, Kazuhiko; Yuasa, Kenji

    2008-01-01

    Our purpose was to evaluate the utility of the small region of interest (ROI) method to detect the architecture of cervical lymph nodes and the specificity of time-intensity curves for tissue present in cervical lymph nodes. Specimens were taken from 17 lymph nodes of eight patients (ten sides of the neck) with oral squamous cell carcinoma who underwent dynamic contrast-enhanced magnetic resonance imaging (MRI) and neck dissection between 2005 and 2007 at our hospital. Two methods of constructing time-intensity curves were compared: the conventional method that uses relatively large ROIs, and a new method that uses small ROIs. Curves made with the small ROI method were then compared to histopathological findings for dissected lymph nodes. The small ROI method allowed differences in signal intensity to be discerned at the tissue level, which was not possible with the conventional large ROI method. Curves for normal lymphoid tissue tended to be type I, those for tumor cells tended to be type II, and those for keratinization/necrosis tended to be types III and IV, indicating that time-intensity curves can be specific to tissue type within lymph nodes. The small ROI method was useful for evaluation of the architecture of cervical lymph nodes. (author)

  11. Internal jugular vein patency and treatment methods after neck dissection in patients with oral cancer

    International Nuclear Information System (INIS)

    Makiguchi, Takaya; Yokoo, Satoshi; Miyazaki, Hidetaka; Ogawa, Masaru; Takayama, Yu; Negishi, Akihide

    2014-01-01

    Stenosis and obstruction of the internal jugular vein (IJV) sometimes occur following modified radical neck dissection or selective neck dissection, in which the IJV is preserved. The objective of this study was to assess risk factors for stenosis or obstruction of the IJV following neck dissection. A total of 58 neck dissections performed in 51 patients by the same surgeon at Gunma University Hospital were retrospectively reviewed. The relationships of the patency of the IJV with gender, side of dissection, number of lymph node metastases, invasion out of the lymph node, radiotherapy, and reconstructive method were examined. The patency of the IJV was evaluated postoperatively using enhanced computed tomography. All cases with obstruction of the IJV received postoperative radiotherapy and neck dissection on the left side. Postoperative radiotherapy was a significant risk factor for obstruction of the IJV. Free flap reconstruction was not a risk factor for stenosis and obstruction. The rate of obstruction of the IJV was significantly decreased in cases with pectoral major musculocutaneous flap reconstruction or extended supraomohyoid neck dissection in which the muscle extensively covered the IJV. (author)

  12. Evaluation of myocardial perfusion reserve in patients with CAD using Contrast-Enhanced MRI: A comparison between semiquantitative and quantitative methods

    International Nuclear Information System (INIS)

    Schmitt, M.; Mohrs, O.K.; Petersen, S.E.; Kreitner, K.F.

    2002-01-01

    Objective: Comparison between two semiquantitative methods and a quantitative evaluation of myocardial blood flow (MBF) for assessment of myocardial perfusion reserve (MPR) in patients with CAD. Material and Methods: 9 patients with coronary stenoses>50% were examined with an ECG-gated Saturation Recovery Turbo FLASH sequence by using Gd-DTPA as contrast agent (CA). The entive measurements were performed both during rest and hyperemia induced by adenosine. The up-slopes of the signal-time S(t) curves in the myocardium and left ventricular (LV) cavity were evaluated by a linear fit. MPR was calculated from the original up-slopes of the myocardial S(t) curves and from the up-slopes, which were normalized to the up-slopes of the LV S(t) curves, respectively. For quantification of MBF values, the mathematical model MMID 4 was used and MPR was evaluated from the MBF values. Results: With all tested methods, MPR was reduced in myocardial regions subtended by arteries with stenoses≥70% compared with remote regions. With MMID 4 and the normalized up-slope method, differences between severe ischemic and remote regions were statistically significant. Conclusion: The up-slope method with normalization and quantification with MMID 4 are more sensitive methods to differentiate between remote and ischemic myocardium than the up-slope method without normalization. (orig.) [de

  13. [Observing the density increase curve after intravenous contrast medium administration using a bolus triggering system: a method for detection cardiovascular disorders?].

    Science.gov (United States)

    Stückle, C A; Kickuth, R; Kirchner, E M; Liermann, D; Kirchner, J

    2002-06-01

    Recently bolus tracking systems were developed to improve the timing of intravenous contrast media application in helical computed tomography. We investigated the benefit of this new method as a parameter of the cardiac function. Retrospective analysis of 64 patients which incidentally underwent bolus triggered contrast enhanced helical CT and invasive investigation of the heart within one week. All examinations were performed on the CT scanner Somatom Plus 4 Volume Zoom (Siemens Corp., Forchheim, Germany) using the C.A.R.E. Bolus software. This performs repetitive low-dose test scans (e.g. for the abdomen: 140 kV, 20 mA, Tl 0.5 s) and measures the Hounsfield attenuation (increase over the baseline) in a preselected region of interest. The displayed increase of vascular density over the time after peripheral contrast media injection (75 ml lopromid (300 mg/ml), 2 ml/s) was categorised to three types: (a) rapid increase, (b) deceleration before a 100 HE threshold was reached and (c) one or more peaks. The findings of the invasive investigation of the heart were correlated to the findings of the bolus-tracking measurements. The examinations were categorized as follows: 19 type A, 34 type B, 11 type C. We found a high significant correlation between the type of the Hounsfield attenuation and systolic pressure in the left ventricle. There was no correlation between the type of the Hounsfield attenuation and the diastolic pressure in the left ventricle, the pressures related to the right ventricle or the ejection fraction. The bolus-tacking system showed a sensitivity of 53, a specificity of 82, an accuracy of 70%, a positive predictive value of 70% and a negative predictive value of 70% in detection of left heart failure. The bolus tracking system C.A.R.E.-bolus often shows atypical Hounsfield attenuation in cases of cardiac failure but is not suitable as a screening method of the cardiopulmonary function.

  14. Visualizing the Impacts of Movement Infrastructures on Social Inclusion: Graph-Based Methods for Observing Community Formations in Contrasting Geographic Contexts

    Directory of Open Access Journals (Sweden)

    Jamie O'Brien

    2017-12-01

    Full Text Available In this article we describe some innovative methods for observing the possible impacts of roads, junctions and pathways (movement infrastructures, on community life in terms of their affordances and hindrances for social connectivity. In seeking to observe these impacts, we combined a range of visualization research methods, based on qualitative points-data mapping, graphic representation and urban morphological analysis at local and global geographic scales. Our overall aim in this study was to develop exploratory methods for combining and visualizing various kinds of data that relate to urban community formations in contrasting urban contexts. We focused our enquiry on the perspectives of adolescents in two urban contexts: Liverpool, UK, and Medellín, Colombia. While they contrast in their geo-political and cultural characteristics, these two cities each present polarized socio-economic inequalities across distinctive spatial patterns. We found that adolescents in these cities offer generally localized, pedestrian perspectives of their local areas, and unique insights into the opportunities and challenges for place-making in their local community spaces. We gathered the communities’ local perspectives through map-making workshops, in which participants used given iconographic symbols to select and weight the social and structural assets that they deemed to be significant features of their community spaces. We then sampled and visualized these selective points data to observe ways in which local community assets relate to infrastructural affordances for movement (in terms of network integration. This analysis was based on the theory and method of Space Syntax, which provides a model of affordances for movement across the urban network over various scales of network configuration. In particular, we sought to determine how city-scale movement infrastructures interact with local-scale infrastructures, and to develop methods for observing ways

  15. Dental and dental hygiene students' diagnostic accuracy in oral radiology: effect of diagnostic strategy and instructional method.

    Science.gov (United States)

    Baghdady, Mariam T; Carnahan, Heather; Lam, Ernest W N; Woods, Nicole N

    2014-09-01

    There has been much debate surrounding diagnostic strategies and the most appropriate training models for novices in oral radiology. It has been argued that an analytic approach, using a step-by-step analysis of the radiographic features of an abnormality, is ideal. Alternative research suggests that novices can successfully employ non-analytic reasoning. Many of these studies do not take instructional methodology into account. This study evaluated the effectiveness of non-analytic and analytic strategies in radiographic interpretation and explored the relationship between instructional methodology and diagnostic strategy. Second-year dental and dental hygiene students were taught four radiographic abnormalities using basic science instructions or a step-by-step algorithm. The students were tested on diagnostic accuracy and memory immediately after learning and one week later. A total of seventy-three students completed both immediate and delayed sessions and were included in the analysis. Students were randomly divided into two instructional conditions: one group provided a diagnostic hypothesis for the image and then identified specific features to support it, while the other group first identified features and then provided a diagnosis. Participants in the diagnosis-first condition (non-analytic reasoning) had higher diagnostic accuracy then those in the features-first condition (analytic reasoning), regardless of their learning condition. No main effect of learning condition or interaction with diagnostic strategy was observed. Educators should be mindful of the potential influence of analytic and non-analytic approaches on the effectiveness of the instructional method.

  16. New casemix classification as an alternative method for budget allocation in thai oral healthcare service: a pilot study.

    Science.gov (United States)

    Wisaijohn, Thunthita; Pimkhaokham, Atiphan; Lapying, Phenkhae; Itthichaisri, Chumpot; Pannarunothai, Supasit; Igarashi, Isao; Kawabuchi, Koichi

    2010-01-01

    This study aimed to develop a new casemix classification system as an alternative method for the budget allocation of oral healthcare service (OHCS). Initially, the International Statistical of Diseases and Related Health Problem, 10th revision, Thai Modification (ICD-10-TM) related to OHCS was used for developing the software "Grouper". This model was designed to allow the translation of dental procedures into eight-digit codes. Multiple regression analysis was used to analyze the relationship between the factors used for developing the model and the resource consumption. Furthermore, the coefficient of variance, reduction in variance, and relative weight (RW) were applied to test the validity. The results demonstrated that 1,624 OHCS classifications, according to the diagnoses and the procedures performed, showed high homogeneity within groups and heterogeneity between groups. Moreover, the RW of the OHCS could be used to predict and control the production costs. In conclusion, this new OHCS casemix classification has a potential use in a global decision making.

  17. New Casemix Classification as an Alternative Method for Budget Allocation in Thai Oral Healthcare Service: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Thunthita Wisaijohn

    2010-01-01

    Full Text Available This study aimed to develop a new casemix classification system as an alternative method for the budget allocation of oral healthcare service (OHCS. Initially, the International Statistical of Diseases and Related Health Problem, 10th revision, Thai Modification (ICD-10-TM related to OHCS was used for developing the software “Grouper”. This model was designed to allow the translation of dental procedures into eight-digit codes. Multiple regression analysis was used to analyze the relationship between the factors used for developing the model and the resource consumption. Furthermore, the coefficient of variance, reduction in variance, and relative weight (RW were applied to test the validity. The results demonstrated that 1,624 OHCS classifications, according to the diagnoses and the procedures performed, showed high homogeneity within groups and heterogeneity between groups. Moreover, the RW of the OHCS could be used to predict and control the production costs. In conclusion, this new OHCS casemix classification has a potential use in a global decision making.

  18. A new automated assessment method for contrast-detail images by applying support vector machine and its robustness to nonlinear image processing.

    Science.gov (United States)

    Takei, Takaaki; Ikeda, Mitsuru; Imai, Kuniharu; Yamauchi-Kawaura, Chiyo; Kato, Katsuhiko; Isoda, Haruo

    2013-09-01

    The automated contrast-detail (C-D) analysis methods developed so-far cannot be expected to work well on images processed with nonlinear methods, such as noise reduction methods. Therefore, we have devised a new automated C-D analysis method by applying support vector machine (SVM), and tested for its robustness to nonlinear image processing. We acquired the CDRAD (a commercially available C-D test object) images at a tube voltage of 120 kV and a milliampere-second product (mAs) of 0.5-5.0. A partial diffusion equation based technique was used as noise reduction method. Three radiologists and three university students participated in the observer performance study. The training data for our SVM method was the classification data scored by the one radiologist for the CDRAD images acquired at 1.6 and 3.2 mAs and their noise-reduced images. We also compared the performance of our SVM method with the CDRAD Analyser algorithm. The mean C-D diagrams (that is a plot of the mean of the smallest visible hole diameter vs. hole depth) obtained from our devised SVM method agreed well with the ones averaged across the six human observers for both original and noise-reduced CDRAD images, whereas the mean C-D diagrams from the CDRAD Analyser algorithm disagreed with the ones from the human observers for both original and noise-reduced CDRAD images. In conclusion, our proposed SVM method for C-D analysis will work well for the images processed with the non-linear noise reduction method as well as for the original radiographic images.

  19. The Method of Culture Contrast

    DEFF Research Database (Denmark)

    Hasse, Cathrine; Trentemøller, Stine; Motzkau, Johanna

    2009-01-01

    -cultural research can be argued to rest on what has been called implicit comparisons (Nader 1994) of such categorisations. We assume that research of local activities, such as schooling and higher education, is influenced by the researcher's emic and etic categorisations. To get beyond the risk of reproducing...... and surprising challenges of the researcher's emic categorisations. We illustrate the case with examples of different understandings of three terms, hierarchy, family, and sexual harassment, in the Understanding Puzzles in the Gendered European Map (UPGEM) project....

  20. Toward a new and noninvasive diagnostic method of papillary thyroid cancer by using peptide vectorized contrast agents targeted to galectin-1.

    Science.gov (United States)

    Fanfone, Deborah; Despretz, Nadège; Stanicki, Dimitri; Rubio-Magnieto, Jenifer; Fossépré, Mathieu; Surin, Mathieu; Rorive, Sandrine; Salmon, Isabelle; Vander Elst, Luce; Laurent, Sophie; Muller, Robert N; Saussez, Sven; Burtea, Carmen

    2017-10-06

    The incidence of papillary thyroid cancer has increased these last decades due to a better detection. High prevalence of nodules combined with the low incidence of thyroid cancers constitutes an important diagnostic challenge. We propose to develop an alternative diagnostic method to reduce the number of useless and painful thyroidectomies using a vectorized contrast agent for magnetic resonance imaging. Galectin-1 (gal-1), a protein overexpressed in well-differentiated thyroid cancer, has been targeted with a randomized linear 12-mer peptide library using the phage display technique. Selected peptides have been conjugated to ultrasmall superparamagnetic particles of iron oxide (USPIO). Peptides and their corresponding contrast agents have been tested in vitro for their specific binding and toxicity. Two peptides (P1 and P7) were selected according to their affinity toward gal-1. Their binding has been revealed by immunohistochemistry on human thyroid cancer biopsies, and they were co-localized with gal-1 by immunofluorescence on TPC-1 cell line. Both peptides induce a decrease in TPC-1 cells' adhesion to gal-1 immobilized on culture plates. After coupling to USPIO, the peptides preserved their affinity toward gal-1. Their specific binding has been corroborated by co-localization with gal-1 expressed by TPC-1 cells and by their ability to compete with anti-gal-1 antibody. The peptides and their USPIO derivatives produce no toxicity in HepaRG cells as determined by MTT assay. The vectorized contrast agents are potential imaging probes for thyroid cancer diagnosis. Moreover, the two gal-1-targeted peptides prevent cancer cell adhesion by interacting with the carbohydrate-recognition domain of gal-1.

  1. Quantitative Analysis of First-Pass Contrast-Enhanced Myocardial Perfusion Multidetector CT Using a Patlak Plot Method and Extraction Fraction Correction During Adenosine Stress

    Science.gov (United States)

    Ichihara, Takashi; George, Richard T.; Silva, Caterina; Lima, Joao A. C.; Lardo, Albert C.

    2011-02-01

    The purpose of this study was to develop a quantitative method for myocardial blood flow (MBF) measurement that can be used to derive accurate myocardial perfusion measurements from dynamic multidetector computed tomography (MDCT) images by using a compartment model for calculating the first-order transfer constant (K1) with correction for the capillary transit extraction fraction (E). Six canine models of left anterior descending (LAD) artery stenosis were prepared and underwent first-pass contrast-enhanced MDCT perfusion imaging during adenosine infusion (0.14-0.21 mg/kg/min). K1 , which is the first-order transfer constant from left ventricular (LV) blood to myocardium, was measured using the Patlak plot method applied to time-attenuation curve data of the LV blood pool and myocardium. The results were compared against microsphere MBF measurements, and the extraction fraction of contrast agent was calculated. K1 is related to the regional MBF as K1=EF, E=(1-exp(-PS/F)), where PS is the permeability-surface area product and F is myocardial flow. Based on the above relationship, a look-up table from K1 to MBF can be generated and Patlak plot-derived K1 values can be converted to the calculated MBF. The calculated MBF and microsphere MBF showed a strong linear association. The extraction fraction in dogs as a function of flow (F) was E=(1-exp(-(0.2532F+0.7871)/F)) . Regional MBF can be measured accurately using the Patlak plot method based on a compartment model and look-up table with extraction fraction correction from K1 to MBF.

  2. Online video in clinical skills education of oral medication administration for undergraduate student nurses: a mixed methods, prospective cohort study.

    Science.gov (United States)

    Holland, Agi; Smith, Fiona; McCrossan, Gill; Adamson, Elizabeth; Watt, Susan; Penny, Kay

    2013-06-01

    Improvements in the safety of the prescribing, dispensing and administration of medicines are identified as a priority across international healthcare systems. It is therefore essential that higher education institutions play their part in helping to meet this patient safety objective. New developments in clinical skills education which are aligned to emerging educational theory are available, but evaluations and supportive evidence are limited. To evaluate the use of an online best practice exemplar as an adjunct to the clinical skills teaching of oral medication administration to undergraduate student nurses. Mixed-methods prospective cohort design. Two intakes of undergraduate nursing students (n=168, n=154) undertaking a first year clinical skills based module at a British university. The Control group received standard teaching using lectures and skills classes facilitated by experienced clinical skills lecturers. The Intervention group received the standard teaching and unlimited access to an online video clip of medication administration. Performance and satisfaction were measured using module assessment results and a satisfaction questionnaire. Qualitative data were gathered using focus groups (n=16, n=20). The Intervention group was significantly (p=0.021) more likely to pass the assessment and rate their satisfaction with the teaching significantly higher (pTeaching and Time and when Classroom Learning was positive, the Transfer to Practice of the clinical skill was enhanced. An online video of a best practice exemplar as an adjunct to taught clinical skills sessions improves student assessment results and satisfaction ratings. The video was also reported to positively influence all themes identified in Classroom Learning and was perceived to promote the Transfer to Practice of teaching input. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. A novel prothrombin time method to measure all non-vitamin K-dependent oral anticoagulants (NOACs)

    Science.gov (United States)

    Lindahl, Tomas L.; Arbring, Kerstin; Wallstedt, Maria; Rånby, Mats

    2017-01-01

    Background There is a clinical need for point-of-care (POC) methods for non-vitamin K-dependent oral anticoagulants (NOACs). We modified a routine POC procedure: Zafena’s Simple Simon™ PT-INR, a room-temperature, wet-chemistry prothrombin time method of the Owren-type. Methods To either increase or decrease NOAC interference, two assay variants were devised by replacing the standard 10 µL end-to-end capillary used to add the citrated plasma sample to 200 µL of prothrombin time (PT) reagent by either a 20 µL or a 5 µL capillary. All assay variants were calibrated to show correct PT results in plasma samples from healthy and warfarin-treated persons. Results For plasmas spiked with dabigatran, apixaban, or rivaroxaban, the 20 µL variant showed markedly higher PT results than the 5 µL. The effects were even more pronounced at room temperature than at +37 °C. In plasmas from patients treated with NOACs (n = 30 for each) there was a strong correlation between the PT results and the concentration of NOACs as determined by the central hospital laboratory. For the 20 µL variant the PT response of linear correlation coefficient averaged 0.90. The PT range was INR 1.1–2.1 for dabigatran and apixaban, and INR 1.1–5.0 for rivaroxaban. Using an INR ratio between the 20 µL and 5 µL variants (PTr20/5) made the NOAC assay more robust and independent of the patient sample INR value in the absence of NOAC. Detection limits were 80 µg/L for apixaban, 60 µg/L for dabigatran, and 20 µg/L for rivaroxaban. Conclusions A wet-chemistry POC PT procedure was modified to measure the concentrations of three NOACs using a single reagent. PMID:28891412

  4. Oral myiasis

    Directory of Open Access Journals (Sweden)

    Thalaimalai Saravanan

    2015-01-01

    Full Text Available Myiasis is a pathologic condition in humans occurring because of parasitic infestation. Parasites causing myiasis belong to the order Diptera. Oral myiasis is seen secondary to oral wounds, suppurative lesions, and extraction wounds, especially in individuals with neurological deficit. In such cases, neglected oral hygiene and halitosis attracts the flies to lay eggs in oral wounds resulting in oral myiasis. We present a case of oral myiasis in 40-year-old male patient with mental disability and history of epilepsy.

  5. Contrast-enhanced 3T MR perfusion of musculoskeletal tumours. T1 value heterogeneity assessment and evaluation of the influence of T1 estimation methods on quantitative parameters

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Verbizier, Jacques de; Blum, Alain [Hopital Central, CHRU-Nancy, Service d' Imagerie Guilloz, Nancy (France); Chen, Bailiang; Beaumont, Marine [Universite de Lorraine, Laboratoire IADI, UMR S 947, Nancy (France); Badr, Sammy; Cotten, Anne [CHRU Lille Centre de Consultations et d' Imagerie de l' Appareil Locomoteur, Department of Radiology and Musculoskeletal Imaging, Lille (France)

    2017-12-15

    To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. (orig.)

  6. First international collaborative study to evaluate rabies antibody detection method for use in monitoring the effectiveness of oral vaccination programmes in fox and raccoon dog in Europe

    DEFF Research Database (Denmark)

    Wasniewski, M; Almeida, I; Baur, A

    2016-01-01

    The most effective and sustainable method to control and eliminate rabies in wildlife is the oral rabies vaccination (ORV) of target species, namely foxes and raccoon dogs in Europe. According to WHO and OIE, the effectiveness of oral vaccination campaigns should be regularly assessed via disease...... surveillance and ORV antibody monitoring. Rabies antibodies are generally screened for in field animal cadavers, whose body fluids are often of poor quality. Therefore, the use of alternative methods such as the enzyme-linked immunosorbent assay (ELISA) has been proposed to improve reliability of serological...... results obtained on wildlife samples. We undertook an international collaborative study to determine if the commercial BioPro ELISA Rabies Ab kit is a reliable and reproducible tool for rabies serological testing. Our results reveal that the overall specificity evaluated on naive samples reached 96...

  7. Oral cancer

    Science.gov (United States)

    Cancer - mouth; Mouth cancer; Head and neck cancer; Squamous cell cancer - mouth; Malignant neoplasm - oral ... National Cancer Institute. PDQ lip and oral cavity cancer ... September 25, 2015. www.cancer.gov/types/head-and-neck/hp/lip- ...

  8. Oral Ketamine

    African Journals Online (AJOL)

    Oral Ketamine: A Four-years Experience in ... Key words: Oral Ketamine, Premedication and Oncology. .... form of a letter published in 19835. .... Acta. Anaesthesiol Scandinavica, 1998; 42: 750-758. 4. Murray P. Substitution of another opioid ...

  9. A simple validated multi-analyte method for detecting drugs in oral fluid by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).

    Science.gov (United States)

    Zheng, Yufang; Sparve, Erik; Bergström, Mats

    2018-06-01

    A UPLC-MS/MS method was developed to identify and quantitate 37 commonly abused drugs in oral fluid. Drugs of interest included amphetamines, benzodiazepines, cocaine, opiates, opioids, phencyclidine and tetrahydrocannabinol. Sample preparation and extraction are simple, and analysis times short. Validation showed satisfactory performance at relevant concentrations. The possibility of contaminated samples as well as the interpretation in relation to well-knows matrices, such as urine, will demand further study. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Oral seal using glue: a new method to distinguish between intestinal and dermal uptake of metals in earthworms.

    NARCIS (Netherlands)

    Vijver, M.G.; Vink, J.P.M.; Miermans, C.J.H.; van Gestel, C.A.M.

    2003-01-01

    Earthworms may take up chemicals from soil and pore water, both through their skin (dermal) and by ingestion (oral). It remains unclear, however, what the relative importance of these pathways is. To assess bioavailability of pollutants in soil to earthworms, it is necessary that the contribution of

  11. Dynamic contrast-enhanced magnetic resonance imaging: a non-invasive method to evaluate significant differences between malignant and normal tissue

    International Nuclear Information System (INIS)

    Rudisch, Ansgar; Kremser, Christian; Judmaier, Werner; Zunterer, Hildegard; DeVries, Alexander F.

    2005-01-01

    Purpose: An ever recurring challenge in diagnostic radiology is the differentiation between non-malignant and malignant tissue. Based on evidence that microcirculation of normal, non-malignant tissue differs from that of malignant tissue, the goal of this study was to assess the reliability of dynamic contrast-enhanced Magnetic Resonance Imaging (dcMRI) for differentiating these two entities. Materials and methods: DcMRI data of rectum carcinoma and gluteus maximus muscles were acquired in 41 patients. Using an fast T1-mapping sequence on a 1.5-T whole body scanner, T1-maps were dynamically retrieved before, during and after constant rate i.v. infusion of a contrast medium (CM). On the basis of the acquired data sets, PI-values were calculated on a pixel-by-pixel basis. The relevance of spatial heterogeneities of microcirculation was investigated by relative frequency histograms of the PI-values. Results: A statistically significant difference between malignant and normal tissue was found for the mean PI-value (P < 0.001; 8.95 ml/min/100 g ± 2.45 versus 3.56 ml/min/100 g ± 1.20). Additionally relative frequency distributions of PI-values with equal class intervals of 2.5 ml/min/100 g revealed significant differences between the histograms of muscles and rectum carcinoma. Conclusion: We could show that microcirculation differences between malignant and normal, non-malignant tissue can be reliably assessed by non-invasive dcMRI. Therefore, dcMRI holds great promise in the aid of cancer assessment, especially in patients where biopsy is contraindicated

  12. Contrast media in gall bladder diagnostics

    International Nuclear Information System (INIS)

    Schindler, G.; Frommhold, W.

    1982-01-01

    The justification of conventional X-ray diagnostic of bile ducts is repeatedly questioned by newer examination techniques like sonography and ERC. The indication for oral cholesgraphy is derived from its high-specifity of its statements for gall bladder diagnostic, that is as high as with sonography and does not depend on the experience of the investigator. The importance of the the void exposure is undoubted with correspondence of medicamentary litholysis for calcite identification. Furthermore, Choleocystic kineticals like Ceruletid let recognize better hyper plastic choleocysts like adenomyomatoses. The intravenous choleocyst-cholangiography posesses a clearly limited indication scheme even after introduction of sonography and ERC. The infusion method yields a better compatibility of the contrast medium with a simultaneous increased representation quality of the bile duct, that can be increased by a consequent application of the layer exposure technique. (orig.) [de

  13. Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (I): Theory, method, and phantom experiments.

    Science.gov (United States)

    van Schie, Jeroen J N; Lavini, Cristina; van Vliet, Lucas J; Vos, Frans M

    2018-05-01

    The arterial input function (AIF) represents the time-dependent arterial contrast agent (CA) concentration that is used in pharmacokinetic modeling. To develop a novel method for estimating the AIF from dynamic contrast-enhanced (DCE-) MRI data, while compensating for flow enhancement. Signal simulation and phantom measurements. Time-intensity curves (TICs) were simulated for different numbers of excitation pulses modeling flow effects. A phantom experiment was performed in which a solution (without CA) was passed through a straight tube, at constant flow velocity. Dynamic fast spoiled gradient echo (FSPGRs) at 3T MRI, both in the simulations and in the phantom experiment. TICs were generated for a duration of 373 seconds and sampled at intervals of 1.247 seconds (300 timepoints). The proposed method first estimates the number of pulses that spins have received, and then uses this knowledge to accurately estimate the CA concentration. The difference between the median of the estimated number of pulses and the true value was determined, as well as the interquartile range (IQR) of the estimations. The estimated CA concentrations were evaluated in the same way. The estimated number of pulses was also used to calculate flow velocity. The difference between the median estimated and reference number of pulses varied from -0.005 to -1.371 (corresponding IQRs: 0.853 and 48.377) at true values of 10 and 180 pulses, respectively. The difference between the median estimated CA concentration and the reference value varied from -0.00015 to 0.00306 mmol/L (corresponding IQRs: 0.01989 and 1.51013 mmol/L) at true values of 0.5 and 8.0 mmol/l, respectively, at an intermediate value of 100 pulses. The estimated flow velocities in the phantom were within 10% of the reference value. The proposed method accurately corrects the MRI signal affected by the inflow effect. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1190-1196. © 2017 International Society for Magnetic

  14. Comparing clinical effects of photodynamic therapy as a novel method with topical corticosteroid for treatment of Oral Lichen Planus.

    Science.gov (United States)

    Bakhtiari, Sedigheh; Azari-Marhabi, Saranaz; Mojahedi, Seyyed Masoud; Namdari, Mahshid; Rankohi, Zahra Elmi; Jafari, Soudeh

    2017-12-01

    Oral lichen planus is an autoimmune disorder with several challenges in treatment. Photodynamic therapy has been proposed as a new treatment option for the disease. The present study compared the clinical effects of photodynamic therapy to dexamethasone mouthwash in the treatment of oral lichen planus lesions. In this randomized clinical trial, 30 patients with oral lichen planus were included.15 patients were treated with 5% methylene blue mediated photodynamic therapy using Fotosan device for 30s (630nm wavelength and 7.2-14.4J/cm 2 dose) for 4 sessions in the days 1, 4, 7, 14. In another group, the treatment was done on 15 patients by 0.5mg tab dexamethasone solution in 5cc water, rinsed 4 times in a day within two weeks. The sign score, symptoms scores (pain), clinical severity and treatment efficacy were measured at the days 15, 30, 60, 90 after beginning of the treatment. The results were subjected to Mann-whitney U test in both groups. No significant difference existed between the two modalities regarding the treatment efficacy index, sign score, symptom score and clinical severity on the 15, 30, 60 and 90 post-treatment days. Decreases in patient's symptoms were statistically significant in both groups. Photodynamic therapy was as effective as the dexamethasone mouth wash in the treatment of oral lichen planus. It could be used as a safe modality in the treatment of oral lichen planus lesions without identified side effects. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Comparison of designing simple steel frame & coaxial brace systems by contrast of blast, using two methods of load & resistance coefficients & performance surfaces

    Directory of Open Access Journals (Sweden)

    P. Hassanvand

    2016-12-01

    Full Text Available Nowadays, because of the increasing terrorist attacks around the urban areas, designing buildings by contrast of resulted loads of blast came into consideration particularly in some sensitive buildings & vital arteries. When a blast occurs, the resulted emissions in environment leads to appearance of several penalties and endangers to the human life. Steel structures generally are designed on the basis of standard seismic and gravity loads, it is necessary to investigate the implantation of these structures under the impact of the loads originated from blast. This article presents numerical studies of two-dimensional structural models with 2 and 5 stories which are including simple steel frame system in addition to CBF. The models were analyzed by nonlinear dynamic analysis method using the instruction UFC 3-340-02 in two adverse levels of blast loads by SAP 2000 software. In this study structural models are designed and analyzed using two designing methods: the basic performance design, and Load and Resistance Factor Design (LRFD. Finally, two set of results are compared in detail.

  16. Individual and pen-based oral fluid sampling: A welfare-friendly sampling method for group-housed gestating sows.

    Science.gov (United States)

    Pol, Françoise; Dorenlor, Virginie; Eono, Florent; Eudier, Solveig; Eveno, Eric; Liégard-Vanhecke, Dorine; Rose, Nicolas; Fablet, Christelle

    2017-11-01

    The aims of this study were to assess the feasibility of individual and pen-based oral fluid sampling (OFS) in 35 pig herds with group-housed sows, compare these methods to blood sampling, and assess the factors influencing the success of sampling. Individual samples were collected from at least 30 sows per herd. Pen-based OFS was performed using devices placed in at least three pens for 45min. Information related to the farm, the sows, and their living conditions were collected. Factors significantly associated with the duration of sampling and the chewing behaviour of sows were identified by logistic regression. Individual OFS took 2min 42s on average; the type of floor, swab size, and operator were associated with a sampling time >2min. Pen-based OFS was obtained from 112 devices (62.2%). The type of floor, parity, pen-level activity, and type of feeding were associated with chewing behaviour. Pen activity was associated with the latency to interact with the device. The type of floor, gestation stage, parity, group size, and latency to interact with the device were associated with a chewing time >10min. After 15, 30 and 45min of pen-based OFS, 48%, 60% and 65% of the sows were lying down, respectively. The time spent after the beginning of sampling, genetic type, and time elapsed since the last meal were associated with 50% of the sows lying down at one time point. The mean time to blood sample the sows was 1min 16s and 2min 52s if the number of operators required was considered in the sampling time estimation. The genetic type, parity, and type of floor were significantly associated with a sampling time higher than 1min 30s. This study shows that individual OFS is easy to perform in group-housed sows by a single operator, even though straw-bedded animals take longer to sample than animals housed on slatted floors, and suggests some guidelines to optimise pen-based OFS success. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Contrast source inversion (CSI) method to cross-hole radio-imaging (RIM) data - Part 2: A complex synthetic example and a case study

    Science.gov (United States)

    Li, Yongxing; Smith, Richard S.

    2018-03-01

    We present two examples of using the contrast source inversion (CSI) method to invert synthetic radio-imaging (RIM) data and field data. The synthetic model has two isolated conductors (one perfect conductor and one moderate conductor) embedded in a layered background. After inversion, we can identify the two conductors on the inverted image. The shape of the perfect conductor is better resolved than the shape of the moderate conductor. The inverted conductivity values of the two conductors are approximately the same, which demonstrates that the conductivity values cannot be correctly interpreted from the CSI results. The boundaries and the tilts of the upper and the lower conductive layers on the background can also be inferred from the results, but the centre parts of conductive layers in the inversion results are more conductive than the parts close to the boreholes. We used the straight-ray tomographic imaging method and the CSI method to invert the RIM field data collected using the FARA system between two boreholes in a mining area in Sudbury, Canada. The RIM data include the amplitude and the phase data collected using three frequencies: 312.5 kHz, 625 kHz and 1250 kHz. The data close to the ground surface have high amplitude values and complicated phase fluctuations, which are inferred to be contaminated by the reflected or refracted electromagnetic (EM) fields from the ground surface, and are removed for all frequencies. Higher-frequency EM waves attenuate more quickly in the subsurface environment, and the locations where the measurements are dominated by noise are also removed. When the data are interpreted with the straight-ray method, the images differ substantially for different frequencies. In addition, there are some unexpected features in the images, which are difficult to interpret. Compared with the straight-ray imaging results, the inversion results with the CSI method are more consistent for different frequencies. On the basis of what we learnt

  18. On the Robustness and Prospects of Adaptive BDDC Methods for Finite Element Discretizations of Elliptic PDEs with High-Contrast Coefficients

    KAUST Repository

    Zampini, Stefano

    2016-06-02

    Balancing Domain Decomposition by Constraints (BDDC) methods have proven to be powerful preconditioners for large and sparse linear systems arising from the finite element discretization of elliptic PDEs. Condition number bounds can be theoretically established that are independent of the number of subdomains of the decomposition. The core of the methods resides in the design of a larger and partially discontinuous finite element space that allows for fast application of the preconditioner, where Cholesky factorizations of the subdomain finite element problems are additively combined with a coarse, global solver. Multilevel and highly-scalable algorithms can be obtained by replacing the coarse Cholesky solver with a coarse BDDC preconditioner. BDDC methods have the remarkable ability to control the condition number, since the coarse space of the preconditioner can be adaptively enriched at the cost of solving local eigenproblems. The proper identification of these eigenproblems extends the robustness of the methods to any heterogeneity in the distribution of the coefficients of the PDEs, not only when the coefficients jumps align with the subdomain boundaries or when the high contrast regions are confined to lie in the interior of the subdomains. The specific adaptive technique considered in this paper does not depend upon any interaction of discretization and partition; it relies purely on algebraic operations. Coarse space adaptation in BDDC methods has attractive algorithmic properties, since the technique enhances the concurrency and the arithmetic intensity of the preconditioning step of the sparse implicit solver with the aim of controlling the number of iterations of the Krylov method in a black-box fashion, thus reducing the number of global synchronization steps and matrix vector multiplications needed by the iterative solver; data movement and memory bound kernels in the solve phase can be thus limited at the expense of extra local ops during the setup of

  19. The assessment of the breath hold and the free breath methods about the blood flow evaluation by using phase contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Ho [Dept. of Radiology, Konkuk Medical center, Seoul (Korea, Republic of)

    2016-06-15

    Measurement of cardiac blood flow using the magnetic resonance imaging has been limited due to breathing and involuntary movements of the heart. The present study attempted to improve the accuracy of cardiac blood flow testing through phase contrast magnetic resonance imaging by presenting the adequate breathing method and imaging variables by comparing the measurement values of cardiac blood flow. Each was evaluated by comparing the breath hold retrospective 1NEX and non breath hold retrospective 1-3NEX in the ascending aorta and descending aorta. As a result, the average blood flow amount/ velocity of the breath hold retrosepctive 1NEX method in the ascending aorta were 96.17±19.12 ml/sec, 17.04±4.12 cm/sec respectively, which demonstrates a statistically significant difference(p<0.05) with the non-breath hold retrospective method 1NEX of 72.31±13.27 ml and 12.32±3.85. On the other hand, the average 2NEX blood flow and mean flow velocity is 101.90±24.09, 16.84±4.32, 3NEX 103.06±25.49, 16.88±4.19 did not show statistically significant differences(p>0.05).The average blood flow amount/ velocity of the breath hold retrospective 1NEX method in the descending aorta were 76.68±19.72 ml/s, and 22.23±4.8, which did not demonstrate a significant difference in comparison to non-breath hold retrospective method 1-3 NEX. Therefore, the non breath hold retrospective method does not significantly differ in terms of cardiac blood flow in comparison with the breath hold retrospective method in accordance with the increase of NEX, so pediatric patients or patients who are not able to breathe well must have the diagnostic value of their cardiac blood flow tests improved.

  20. Wound biofilms: lessons learned from oral biofilms

    OpenAIRE

    Mancl, Kimberly A.; Kirsner, Robert S.; Ajdic, Dragana

    2013-01-01

    Biofilms play an important role in the development and pathogenesis of many chronic infections. Oral biofilms, more commonly known as dental plaque,are a primary cause of oral diseases including caries, gingivitis and periodontitis. Oral biofilms are commonly studied as model biofilm systems as they are easily accessible, thus biofilm research in oral diseases is advanced with details of biofilm formation and bacterial interactions being well-elucidated. In contrast, wound research has relati...

  1. Nutrition and Oral Health: Experiences in Iran

    OpenAIRE

    Zohre Sadat Sangsefidi; Amin Salehi-Abargouei

    2017-01-01

    Background: Oral health is a crucial factor for overall well-being and there is a mutual relationship between nutrition and oral health. The aim of this study was to review the publications which have examined the association between nutrition or diet and oral health status or oral disease in Iran. Methods: The electronic databases of PubMed, Scopus, Google scholar, scientific information database (SID), and Magiran were searched using key words of diet, nutrition, oral health, oral disease, ...

  2. Oral symptoms and functional outcome related to oral and oropharyngeal cancer

    NARCIS (Netherlands)

    Kamstra, Jolanda I.; Jager-Wittenaar, Harriet; Dijkstra, Pieter U.; Huisman, Paulien M.; van Oort, Rob P.; van der Laan, Bernard F. A. M.; Roodenburg, Jan L. N.

    Purpose This study aimed to assess: (1) oral symptoms of patients treated for oral or oropharyngeal cancer; (2) how patients rank the burden of oral symptoms; (3) the impact of the tumor, the treatment, and oral symptoms on functional outcome. Methods Eighty-nine patients treated for oral or

  3. Contrast-enhanced 3T MR Perfusion of Musculoskeletal Tumours: T1 Value Heterogeneity Assessment and Evaluation of the Influence of T1 Estimation Methods on Quantitative Parameters.

    Science.gov (United States)

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Chen, Bailiang; De Verbizier, Jacques; Beaumont, Marine; Badr, Sammy; Cotten, Anne; Blum, Alain

    2017-12-01

    To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. • T1 value variation in musculoskeletal tumours is considerable. • T1 values in muscle and tumours are significantly different. • Patient-specific T1 estimation is needed for comparison of inter-patient perfusion parameters. • Technical variation is higher in permeability than semiquantitative perfusion parameters.

  4. Predicting response before initiation of neoadjuvant chemotherapy in breast cancer using new methods for the analysis of dynamic contrast enhanced MRI (DCE MRI) data

    Science.gov (United States)

    DeGrandchamp, Joseph B.; Whisenant, Jennifer G.; Arlinghaus, Lori R.; Abramson, V. G.; Yankeelov, Thomas E.; Cárdenas-Rodríguez, Julio

    2016-03-01

    The pharmacokinetic parameters derived from dynamic contrast enhanced (DCE) MRI have shown promise as biomarkers for tumor response to therapy. However, standard methods of analyzing DCE MRI data (Tofts model) require high temporal resolution, high signal-to-noise ratio (SNR), and the Arterial Input Function (AIF). Such models produce reliable biomarkers of response only when a therapy has a large effect on the parameters. We recently reported a method that solves the limitations, the Linear Reference Region Model (LRRM). Similar to other reference region models, the LRRM needs no AIF. Additionally, the LRRM is more accurate and precise than standard methods at low SNR and slow temporal resolution, suggesting LRRM-derived biomarkers could be better predictors. Here, the LRRM, Non-linear Reference Region Model (NRRM), Linear Tofts model (LTM), and Non-linear Tofts Model (NLTM) were used to estimate the RKtrans between muscle and tumor (or the Ktrans for Tofts) and the tumor kep,TOI for 39 breast cancer patients who received neoadjuvant chemotherapy (NAC). These parameters and the receptor statuses of each patient were used to construct cross-validated predictive models to classify patients as complete pathological responders (pCR) or non-complete pathological responders (non-pCR) to NAC. Model performance was evaluated using area under the ROC curve (AUC). The AUC for receptor status alone was 0.62, while the best performance using predictors from the LRRM, NRRM, LTM, and NLTM were AUCs of 0.79, 0.55, 0.60, and 0.59 respectively. This suggests that the LRRM can be used to predict response to NAC in breast cancer.

  5. Determination of uranium content in dental porcelains by means of the fission track method and estimation of radiation dose to oral mucosa by radioactive elements

    International Nuclear Information System (INIS)

    Sairenji, E.; Moriwaki, K.; Shimizu, M.; Noguchi, K.

    1980-01-01

    Porcelain teeth, some of which contain uranium compounds for aesthetic purpose, have been widely used in dental clinics. Hazardous effects due to uranium radiation have been suggested in recent publications. In the present study uranium concentrations were determined in four major brands of porcelain teeth marketed in Japan using the fission track method, and the absorbed doses to oral tissued were calculated. Average uranium concentrations of the brands studied were determined to be 3.6 ppm (0.33-10 ppm, Japan), 18 ppm (0.69-81 ppm, Japan), 9.4 ppm (2.5-14 ppm, Japan) and 82 ppm (11-205 ppm, U.S.), respectively. The corresponding dose equivalents at the surface of oral mucosal membrane were 2.9 rem yr -1 . 14 rem yr -1 , 7.6 rem yr -1 and 66 rem yr -1 . (author)

  6. Determination of uranium content in dental porcelains by means of the fission track method and estimation of radiation dose to oral mucosa by radioactive elements

    International Nuclear Information System (INIS)

    Sairenji, Eiko; Moriwaki, Kazunari; Shimizu, Masami; Noguchi, Kunikazu; Anzai, Ikuro.

    1979-01-01

    Porcelain teeth, some of which contained uranium compounds for aesthetic purpose, have been widely used in dental clinics. Recently, the hazardous effects by uranium radiation were suggested. In the present study, the authors carried out the determination of uranium concentrations of four major brands of porcelain teeth marketed in Japan using the fission track method, and the absorbed doses of oral tissues were calculated by the authors' introduced formula for calculation of alpha radiation. Average uranium concentrations of the brands studied were determined 3.6 ppm (0.33 - 10 ppm, Japan), 18 ppm (0.69 - 81 ppm, Japan), 9.4 ppm (2.5 - 14 ppm, Japan) and 82 ppm (11 - 205 ppm, U.S.A.), respectively. The corresponding dose equivalents at the surface of oral mucosal membrane were 2.9 rem y -1 , 14 rem y -1 , 7.6 rem y -1 and 66 rem y -1 . (author)

  7. Pharmacokinetic Comparative Study of Gastrodin and Rhynchophylline after Oral Administration of Different Prescriptions of Yizhi Tablets in Rats by an HPLC-ESI/MS Method

    Science.gov (United States)

    Ge, Zhaohui; Liang, Qionglin; Wang, Yiming; Luo, Guoan

    2014-01-01

    Pharmacokinetic characters of rhynchophylline (RIN), gastrodin (GAS), and gastrodigenin (p-hydroxybenzyl alcohol, HBA) were investigated after oral administration of different prescriptions of Yizhi: Yizhi tablets or effective parts of tianma (total saponins from Gastrodiae, EPT) and gouteng (rhynchophylla alkaloids, EPG). At different predetermined time points after administration, the concentrations of GAS, HBA, and RIN in rat plasma were determined by an HPLC-ESI/MS method, and the main pharmacokinetic parameters were investigated. The results showed that the pharmacokinetic parameters C max and AUC0–∞ (P < 0.05) were dramatically different after oral administration of different prescriptions of Yizhi. The data indicated that the pharmacokinetic processes of GAS, HBA, and RIN in rats would interact with each other or be affected by other components in Yizhi. The rationality of the compatibility of Uncaria and Gastrodia elata as a classic “herb pair” has been verified from the pharmacokinetic viewpoint. PMID:25610474

  8. Pharmacokinetic Comparative Study of Gastrodin and Rhynchophylline after Oral Administration of Different Prescriptions of Yizhi Tablets in Rats by an HPLC-ESI/MS Method

    Directory of Open Access Journals (Sweden)

    Zhaohui Ge

    2014-01-01

    Full Text Available Pharmacokinetic characters of rhynchophylline (RIN, gastrodin (GAS, and gastrodigenin (p-hydroxybenzyl alcohol, HBA were investigated after oral administration of different prescriptions of Yizhi: Yizhi tablets or effective parts of tianma (total saponins from Gastrodiae, EPT and gouteng (rhynchophylla alkaloids, EPG. At different predetermined time points after administration, the concentrations of GAS, HBA, and RIN in rat plasma were determined by an HPLC-ESI/MS method, and the main pharmacokinetic parameters were investigated. The results showed that the pharmacokinetic parameters Cmax and Cmax⁡ and AUC0–∞ (P<0.05 were dramatically different after oral administration of different prescriptions of Yizhi. The data indicated that the pharmacokinetic processes of GAS, HBA, and RIN in rats would interact with each other or be affected by other components in Yizhi. The rationality of the compatibility of Uncaria and Gastrodia elata as a classic “herb pair” has been verified from the pharmacokinetic viewpoint.

  9. Biopsy Diagnosis of Oral Carcinoma by the Combination of Morphological and Spectral Methods Based on Embedded Relay Lens Microscopic Hyperspectral Imaging System.

    Science.gov (United States)

    Ou-Yang, Mang; Hsieh, Yao-Fang; Lee, Cheng-Chung

    Cytopathological examination through biopsy is very important for carcinoma detection. The embedded relay lens microscopic hyperspectral imaging system (ERL-MHIS) provides a morphological image of a biopsy sample and the spectrum of each pixel in the image simultaneously. Based on the ERL-MHIS, this work develops morphological and spectral methods to diagnose oral carcinoma biopsy. In morphological discrimination, the fractal dimension method is applied to differentiate between normal and abnormal tissues. In spectral identification, normal and cancerous cells are distinguished using five methods. However, the spectra of normal and cancerous cells vary with patient. The diagnostic performances of the five methods are thus not ideal. Hence, the proposed cocktail approach is used to determine the effectiveness of the spectral methods in correlating with the sampling conditions. And then we use a combination of effective spectral methods according to the sample conditions for diagnosing a sample. A total of 68 biopsies from 34 patients are analyzed using the ERL-MHIS. The results demonstrate a sensitivity of 90 ± 4.53 % and a specificity of 87.8 ± 5.21 %. Furthermore, in our survey, this system is the first time utilized to study oral carcinoma biopsies.

  10. The Value of Contrast Echocardiography

    Directory of Open Access Journals (Sweden)

    Shannon C. Treiber

    2016-01-01

    Full Text Available Purpose: There is much evidence-based research proving the effectiveness of contrast echocardiography, but there are still questions and concerns about its specific uses. This study tested the effectiveness of contrast echocardiography in defining the left ventricular endocardial border. Methods: From 30 patients, a total of 60 echocardiograms –– 30 with and 30 without use of contrast –– were retrospectively reviewed by four blinded cardiologists with advanced training in echocardiography. No single cardiologist reviewed contrast and noncontrast images of the same patient. Each set of 30 echocardiograms was then studied for wall-motion scoring. Visualization of left ventricular wall segments and a global visualization confidence level of interpretation were recorded. Results: Of all wall segments (N = 510, 91% were visualized in echocardiograms with use of contrast, whereas 75% of the walls were visualized in echocardiograms without contrast (P < 0.001. Of 30 examinations, 17 contrast echocardiograms were read with high confidence compared to 6 without contrast use (P = 0.004. The number of walls visualized with contrast was increased in 18 patients (60%, whereas noncontrast echocardiograms yielded more visualized walls in 6 patients (20%, P = 0.002. Conclusions: This study demonstrates that contrast is valuable to echocardiographic imaging. Its use should be supported throughout echocardiography clinics and encouraged in certain patients for whom resting and stress echocardiography results without contrast often prove uninterpretable.

  11. Contrast Enhanced Microscopy Digital Image Correlation: A General Method to Contact-Free Coefficient of Thermal Expansion Measurement of Polymer Films

    Science.gov (United States)

    Jairo A. Diaz; Robert J. Moon; Jeffrey P. Youngblood

    2014-01-01

    Thermal expansion represents a vital indicator of the processing history and dimensional stability of materials. Solvent-sensitive, thin, and compliant samples are particularly challenging to test. Here we describe how textures highlighted by contrast enhanced optical microscopy modes (i.e., polarized light (PL), phase contrast (PC)) and bright field (BF) can be used...

  12. Non-invasive breast biopsy method using GD-DTPA contrast enhanced MRI series and F-18-FDG PET/CT dynamic image series

    Science.gov (United States)

    Magri, Alphonso William

    This study was undertaken to develop a nonsurgical breast biopsy from Gd-DTPA Contrast Enhanced Magnetic Resonance (CE-MR) images and F-18-FDG PET/CT dynamic image series. A five-step process was developed to accomplish this. (1) Dynamic PET series were nonrigidly registered to the initial frame using a finite element method (FEM) based registration that requires fiducial skin markers to sample the displacement field between image frames. A commercial FEM package (ANSYS) was used for meshing and FEM calculations. Dynamic PET image series registrations were evaluated using similarity measurements SAVD and NCC. (2) Dynamic CE-MR series were nonrigidly registered to the initial frame using two registration methods: a multi-resolution free-form deformation (FFD) registration driven by normalized mutual information, and a FEM-based registration method. Dynamic CE-MR image series registrations were evaluated using similarity measurements, localization measurements, and qualitative comparison of motion artifacts. FFD registration was found to be superior to FEM-based registration. (3) Nonlinear curve fitting was performed for each voxel of the PET/CT volume of activity versus time, based on a realistic two-compartmental Patlak model. Three parameters for this model were fitted; two of them describe the activity levels in the blood and in the cellular compartment, while the third characterizes the washout rate of F-18-FDG from the cellular compartment. (4) Nonlinear curve fitting was performed for each voxel of the MR volume of signal intensity versus time, based on a realistic two-compartment Brix model. Three parameters for this model were fitted: rate of Gd exiting the compartment, representing the extracellular space of a lesion; rate of Gd exiting a blood compartment; and a parameter that characterizes the strength of signal intensities. Curve fitting used for PET/CT and MR series was accomplished by application of the Levenburg-Marquardt nonlinear regression

  13. Contrast Enhancement Method Based on Gray and Its Distance Double-Weighting Histogram Equalization for 3D CT Images of PCBs

    Directory of Open Access Journals (Sweden)

    Lei Zeng

    2016-01-01

    Full Text Available Cone beam computed tomography (CBCT is a new detection method for 3D nondestructive testing of printed circuit boards (PCBs. However, the obtained 3D image of PCBs exhibits low contrast because of several factors, such as the occurrence of metal artifacts and beam hardening, during the process of CBCT imaging. Histogram equalization (HE algorithms cannot effectively extend the gray difference between a substrate and a metal in 3D CT images of PCBs, and the reinforcing effects are insignificant. To address this shortcoming, this study proposes an image enhancement algorithm based on gray and its distance double-weighting HE. Considering the characteristics of 3D CT images of PCBs, the proposed algorithm uses gray and its distance double-weighting strategy to change the form of the original image histogram distribution, suppresses the grayscale of a nonmetallic substrate, and expands the grayscale of wires and other metals. The proposed algorithm also enhances the gray difference between a substrate and a metal and highlights metallic materials. The proposed algorithm can enhance the gray value of wires and other metals in 3D CT images of PCBs. It applies enhancement strategies of changing gray and its distance double-weighting mechanism to adapt to this particular purpose. The flexibility and advantages of the proposed algorithm are confirmed by analyses and experimental results.

  14. Electrochemical reductive dehalogenation of iodine-containing contrast agent pharmaceuticals: Examination of reactions of diatrizoate and iopamidol using the method of rotating ring-disc electrode (RRDE).

    Science.gov (United States)

    Yan, Mingquan; Chen, Zhanghao; Li, Na; Zhou, Yuxuan; Zhang, Chenyang; Korshin, Gregory

    2018-06-01

    This study examined the electrochemical (EC) reduction of iodinated contrast media (ICM) exemplified by iopamidol and diatrizoate. The method of rotating ring-disc electrode (RRDE) was used to elucidate rates and mechanisms of the EC reactions of the selected ICMs. Experiments were carried at varying hydrodynamic conditions, concentrations of iopamidol, diatrizoate, natural organic matter (NOM) and model compounds (resorcinol, catechol, guaiacol) which were used to examine interactions between products of the EC reduction of ICMs and halogenation-active species. The data showed that iopamidol and diatrizoate were EC-reduced at potentials < -0.45 V vs. s.c.e. In the range of potentials -0.65 to -0.85 V their reduction was mass transfer-controlled. The presence of NOM and model compounds did not affect the EC reduction of iopamidol and diatrizoate but active iodine species formed as a result of the EC-induced transformations of these ICMs reacted readily with NOM and model compounds. These data provide more insight into the nature of generation of iodine-containing by-products in the case of reductive degradation of ICMs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. The Fungal Biome of the Oral Cavity.

    Science.gov (United States)

    Chandra, Jyotsna; Retuerto, Mauricio; Mukherjee, Pranab K; Ghannoum, Mahmoud

    2016-01-01

    Organisms residing in the oral cavity (oral microbiota) contribute to health and disease, and influence diseases like gingivitis, periodontitis, and oral candidiasis (the most common oral complication of HIV-infection). These organisms are also associated with cancer and other systemic diseases including upper respiratory infections. There is limited knowledge regarding how oral microbes interact together and influence the host immune system. Characterizing the oral microbial community (oral microbiota) in health and disease represents a critical step in gaining insight into various members of this community. While most of the studies characterizing oral microbiota have focused on bacterial community, there are few encouraging studies characterizing the oral mycobiome (the fungal component of the oral microbiota). Our group recently characterized the oral mycobiome in health and disease focusing on HIV. In this chapter we will describe the methods used by our group for characterization of the oral mycobiome.

  16. The "Performance of Rotavirus and Oral Polio Vaccines in Developing Countries" (PROVIDE) study: description of methods of an interventional study designed to explore complex biologic problems.

    Science.gov (United States)

    Kirkpatrick, Beth D; Colgate, E Ross; Mychaleckyj, Josyf C; Haque, Rashidul; Dickson, Dorothy M; Carmolli, Marya P; Nayak, Uma; Taniuchi, Mami; Naylor, Caitlin; Qadri, Firdausi; Ma, Jennie Z; Alam, Masud; Walsh, Mary Claire; Diehl, Sean A; Petri, William A

    2015-04-01

    Oral vaccines appear less effective in children in the developing world. Proposed biologic reasons include concurrent enteric infections, malnutrition, breast milk interference, and environmental enteropathy (EE). Rigorous study design and careful data management are essential to begin to understand this complex problem while assuring research subject safety. Herein, we describe the methodology and lessons learned in the PROVIDE study (Dhaka, Bangladesh). A randomized clinical trial platform evaluated the efficacy of delayed-dose oral rotavirus vaccine as well as the benefit of an injectable polio vaccine replacing one dose of oral polio vaccine. This rigorous infrastructure supported the additional examination of hypotheses of vaccine underperformance. Primary and secondary efficacy and immunogenicity measures for rotavirus and polio vaccines were measured, as well as the impact of EE and additional exploratory variables. Methods for the enrollment and 2-year follow-up of a 700 child birth cohort are described, including core laboratory, safety, regulatory, and data management practices. Intense efforts to standardize clinical, laboratory, and data management procedures in a developing world setting provide clinical trials rigor to all outcomes. Although this study infrastructure requires extensive time and effort, it allows optimized safety and confidence in the validity of data gathered in complex, developing country settings. © The American Society of Tropical Medicine and Hygiene.

  17. Continuous low-dose oral chemotherapy in recurrent and persistent carcinoma of cervix following chemoradiation: A comparative study between prolonged oral cyclophosphamide and oral etoposide

    Directory of Open Access Journals (Sweden)

    Upasana Baruah

    2014-01-01

    Full Text Available Aim: To compare the efficacy and toxicities of low-dose oral cyclophosphamide and oral etoposide in patients with persistent and recurrent cervical cancer with gross pelvic disease following full course of chemoradiation therapy. Materials and Methods: 30 patients with recurrent and persistent cervical cancer with gross pelvic disease were enrolled in this trial. The patients were randomly divided into two groups of 15 patients each with one group receiving low dose oral cyclophosphamide (100 mg/day and the other group receiving low-dose oral etoposide (50 mg/day. Results were statistically analysed by IBM SPSS Statistics 19. Results: Oral etoposide was not well tolerated with grade 2 neutropenia occurring in 33.3% and grade 3 neutropenia in 6.6% and thrombocytopenia occurring in 13.3%. Oral cyclophosphamide group on the other hand was better tolerated with none of the patients having thrombocytopenia and 6.6% patients having grade 2 neutropenia. There were two complete response (15.38% and one partial response at the end of study (7.6% in the cyclophosphamide group whereas there was no complete response and two partial response (16.6% in the oral etoposide group. Conclusion: Long-term, low-dose oral etoposide was found to be less tolerated without any significant effect with patients with persistent and recurrent cervical cancer with gross pelvic disease following full course of chemoradiation therapy in contrast to oral cyclophosphamide which was found to be effective and well-tolerated by the patients.

  18. Development of a stability-indicating high performance liquid chromatography method for assay of erythromycin ethylsuccinate in powder for oral suspension dosage form

    Directory of Open Access Journals (Sweden)

    Fahimeh Kamarei

    2014-12-01

    Full Text Available In this study an effective method was developed to assay erythromycin ethylsuccinate for an oral suspension dosage form. The chromatographic separation was achieved on an X-Terra™ C18 analytical column. A mixture of acetonitrile–ammonium dihydrogen phosphate buffer (0.025 mol L-1 (60:40, V/V (pH 7.0 was used as the mobile phase, effluent flow rate monitored at 1.0 mL min−1, and UV detection at 205 nm. In forced degradation studies, the effects of acid, base, oxidation, UV light and temperature were investigated showing no interference in the peak of drug. The proposed method was validated in terms of specificity, linearity, robustness, precision and accuracy. The method was linear at concentrations ranging from 400 to 600 μg mL−1, precise (intra- and inter-day relative standard deviations <0.65, accurate (mean recovery; 99.5%. The impurities and degradation products of erythromycin ethylsuccinate were selectively determined with good resolution in both the raw material and the final suspension forms. The method could be useful for both routine analytical and quality control assays of erythromycin ethylsuccinate in commercial powder for an oral suspension dosage form and it could be a very powerful tool to investigate the chemical stability of erythromycin ethylsuccinate.

  19. Effect of different oral hygiene measures on oral malodor in children aged 7-15 years.

    Science.gov (United States)

    Patil, Piyusha S; Pujar, Pallavi; Subbareddy, V V

    2015-01-01

    To evaluate the effect of various oral hygiene measures individually and in combination in reducing oral malodor. A total number of 120 children diagnosed as having oral malodor (oral malodor scores 2 and above) were included in the study. Children were then grouped under four oral hygiene categories (tooth brushing, tongue cleaning, mouth rinsing, and a combination group). There were 30 children in each group. The children were asked to perform oral hygiene methods individually and in combination. The children were then reassessed for oral malodor 2 h later. The results were analyzed and compared. Both individual oral hygiene measure or in combination of tooth brushing, tongue cleaning, and mouth rinsing; all were effective in reducing oral malodor. Significant reduction (P oral malodor was seen when all three oral hygiene measures performed together. Oral malodor was significantly reduced after performing oral hygiene measures individually, but reduced more when used in combination.

  20. Metabolomic Studies of Oral Biofilm, Oral Cancer, and Beyond

    Directory of Open Access Journals (Sweden)

    Jumpei Washio

    2016-06-01

    Full Text Available Oral diseases are known to be closely associated with oral biofilm metabolism, while cancer tissue is reported to possess specific metabolism such as the ‘Warburg effect’. Metabolomics might be a useful method for clarifying the whole metabolic systems that operate in oral biofilm and oral cancer, however, technical limitations have hampered such research. Fortunately, metabolomics techniques have developed rapidly in the past decade, which has helped to solve these difficulties. In vivo metabolomic analyses of the oral biofilm have produced various findings. Some of these findings agreed with the in vitro results obtained in conventional metabolic studies using representative oral bacteria, while others differed markedly from them. Metabolomic analyses of oral cancer tissue not only revealed differences between metabolomic profiles of cancer and normal tissue, but have also suggested a specific metabolic system operates in oral cancer tissue. Saliva contains a variety of metabolites, some of which might be associated with oral or systemic disease; therefore, metabolomics analysis of saliva could be useful for identifying disease-specific biomarkers. Metabolomic analyses of the oral biofilm, oral cancer, and saliva could contribute to the development of accurate diagnostic, techniques, safe and effective treatments, and preventive strategies for oral and systemic diseases.

  1. Metabolomic Studies of Oral Biofilm, Oral Cancer, and Beyond.

    Science.gov (United States)

    Washio, Jumpei; Takahashi, Nobuhiro

    2016-06-02

    Oral diseases are known to be closely associated with oral biofilm metabolism, while cancer tissue is reported to possess specific metabolism such as the 'Warburg effect'. Metabolomics might be a useful method for clarifying the whole metabolic systems that operate in oral biofilm and oral cancer, however, technical limitations have hampered such research. Fortunately, metabolomics techniques have developed rapidly in the past decade, which has helped to solve these difficulties. In vivo metabolomic analyses of the oral biofilm have produced various findings. Some of these findings agreed with the in vitro results obtained in conventional metabolic studies using representative oral bacteria, while others differed markedly from them. Metabolomic analyses of oral cancer tissue not only revealed differences between metabolomic profiles of cancer and normal tissue, but have also suggested a specific metabolic system operates in oral cancer tissue. Saliva contains a variety of metabolites, some of which might be associated with oral or systemic disease; therefore, metabolomics analysis of saliva could be useful for identifying disease-specific biomarkers. Metabolomic analyses of the oral biofilm, oral cancer, and saliva could contribute to the development of accurate diagnostic, techniques, safe and effective treatments, and preventive strategies for oral and systemic diseases.

  2. Evaluation of the Risk of Grade 3 Oral and Pharyngeal Dysphagia Using Atlas-Based Method and Multivariate Analyses of Individual Patient Dose Distributions

    Energy Technology Data Exchange (ETDEWEB)

    Otter, Sophie [Department of Clinical Oncology, Royal Marsden Hospital, Sutton and London (United Kingdom); Schick, Ulrike; Gulliford, Sarah [Department of Clinical Oncology, Royal Marsden Hospital, Sutton and London (United Kingdom); The Institute of Cancer Research, London (United Kingdom); Lal, Punita [Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow India (India); Franceschini, Davide [Department of Radiotherapy and Radiosurgery, Humanitas Research Hospital, Milan (Italy); Newbold, Katie; Nutting, Christopher; Harrington, Kevin [Department of Clinical Oncology, Royal Marsden Hospital, Sutton and London (United Kingdom); The Institute of Cancer Research, London (United Kingdom); Bhide, Shreerang, E-mail: shreerang.bhide@icr.ac.uk [Department of Clinical Oncology, Royal Marsden Hospital, Sutton and London (United Kingdom); The Institute of Cancer Research, London (United Kingdom); Department of Radiotherapy and Radiosurgery, Humanitas Research Hospital, Milan (Italy)

    2015-11-01

    Purpose: The study aimed to apply the atlas of complication incidence (ACI) method to patients receiving radical treatment for head and neck squamous cell carcinomas (HNSCC), to generate constraints based on dose-volume histograms (DVHs), and to identify clinical and dosimetric parameters that predict the risk of grade 3 oral mucositis (g3OM) and pharyngeal dysphagia (g3PD). Methods and Materials: Oral and pharyngeal mucosal DVHs were generated for 253 patients who received radiation (RT) or chemoradiation (CRT). They were used to produce ACI for g3OM and g3PD. Multivariate analysis (MVA) of the effect of dosimetry, clinical, and patient-related variables was performed using logistic regression and bootstrapping. Receiver operating curve (ROC) analysis was also performed, and the Youden index was used to find volume constraints that discriminated between volumes that predicted for toxicity. Results: We derived statistically significant dose-volume constraints for g3OM over the range v28 to v70. Only 3 statistically significant constraints were derived for g3PD v67, v68, and v69. On MVA, mean dose to the oral mucosa predicted for g3OM and concomitant chemotherapy and mean dose to the inferior constrictor (IC) predicted for g3PD. Conclusions: We have used the ACI method to evaluate incidences of g3OM and g3PD and ROC analysis to generate constraints to predict g3OM and g3PD derived from entire individual patient DVHs. On MVA, the strongest predictors were radiation dose (for g3OM) and concomitant chemotherapy (for g3PD).

  3. The comparison the effect of training by means of simulation and oral method on midwives’ skill in management of shoulder dystocia

    Science.gov (United States)

    Kordi, Masoumeh; Erfanian, Fatemeh; Fakari, Farzaneh Rashidi; Dastfan, Fatemeh; Nejad, Keivan Shariati

    2017-01-01

    INTRODUCTION: Shoulder dystocia is one of the obstetric emergencies that are accompanied to serious risks for mother and fetus. It necessitates making the method of training of shoulder dystocia management more efficient, i.e., better management and giving services with higher quality. Thus, this study was carried out to compare the impact of training by simulation and oral technique on the skill of the employed midwives in obstetric clinics at Mashhad city (Iran) in shoulder dystocia management during 2012. METHODS: The current research is a double-group clinical trial that was conducted on 51 members of the employed midwives in the obstetric clinic at Mashhad city in 2012. The questionnaire of personal specification and awareness about shoulder dystocia and practical examination (objective-structured clinical examination) were employed as tools for data collection. The learners were divided into two groups by randomized allocation. Training was done by the presentation of lecture in the oral content group and a short movie was displayed at the end of it. The shoulder dystocia management technique was simulated in another group and through role-playing of instructor application of moulage (station) training was conducted. The period of the training course (4 h) and content of the educational workshop was identical for both groups. The practical examination was held for the learners before and immediately after training course. The given data were analyzed by means of statistical descriptive tests including Mann–Whitney U-test and Wilcoxon test via SPSS software (version 16). The significance level was considered as (P dystocia management skill after intervention in both groups (P dystocia management skill after the intervention was significantly greater in simulation group than in an oral group (P = 0.040). CONCLUSION: Training in simulated delivery room by means of role-playing is an efficient method for training shoulder dystocia management skill, so it is

  4. Development of contrast media

    International Nuclear Information System (INIS)

    Krause, W.

    1993-01-01

    Description of all contrast media (ionic and nonionic monomers, ionic and nonionic dimers) was presented. Chemotoxicity, osmolality and viscosity of some contrast agents were analyzed. The main adverse reactions to ionic and nonionic contrast media were described

  5. Oral Hygiene

    DEFF Research Database (Denmark)

    Sørensen, Marie Toftdahl; Villadsen, Dorte Buxbom

    The aim of the study was to explore how adults with schizo- phrenia describe their lived experiences with oral hygiene. 23 adults with schizophrenia were interviewed within a period of four months in late 2015. Transcriptions of the interviews were analysed using the Reflective Lifeworld Research...... health care professionals and adults with schizophrenia in order to improve oral health, well-being and recovery....

  6. Oral Hygiene

    DEFF Research Database (Denmark)

    Villadsen, Dorte Buxbom; Sørensen, Marie Toftdahl

    2017-01-01

    The aim of the study is to explore how adults with schizophrenia describe their lived experiences with oral hygiene. 23 adults with schizophrenia were interviewed within a period of four months in late 2015. Transcriptions of the interviews were analysed using the Reflective Lifeworld Research ph...... health care professionals and adults with schizophrenia in order to improve oral health, well-being and recovery....

  7. Has the use of molecular methods for the characterization of the human oral microbiome changed our understanding of the role of bacteria in the pathogenesis of periodontal disease?

    Science.gov (United States)

    Wade, William Geoffrey

    2011-03-01

    Only around half of oral bacteria can be grown in the laboratory using conventional culture methods. Molecular methods based on 16S rRNA gene sequence are now available and are being used to characterize the periodontal microbiota in its entirety. This review describes the cultural characterization of the oral and periodontal microbiotas and explores the influence of the additional data now available from culture-independent molecular analyses on current thinking on the role of bacteria in periodontitis. Culture-independent molecular analysis of the periodontal microbiota has shown it to be far more diverse than previously thought. A number of species including some that have yet to be cultured are as strongly associated with disease as those organisms traditionally regarded as periodontal pathogens. Sequencing of bacterial genomes has revealed a high degree of intra-specific genetic diversity. The use of molecular methods for the characterization of the periodontal microbiome has greatly expanded the range of bacterial species known to colonize this habitat. Understanding the interactions between the human host and its commensal bacterial community at the functional level is a priority. © 2011 John Wiley & Sons A/S.

  8. Esvaziamento gástrico após administração oral de contraste em tomografia computadorizada do abdômen: descrição de seis casos

    Directory of Open Access Journals (Sweden)

    Martins Fernando Antonio Nogueira da Cruz

    2004-01-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A lesão pulmonar secundária à aspiração do conteúdo gástrico é complicação associada à perda dos reflexos protetores das vias aéreas. Neste contexto, a realização de exames tomográficos que incluem a contrastação do trato digestivo exige particular atenção em crianças abaixo de cinco anos, que necessitam anestesia geral ou sedação para assegurar imobilidade durante o procedimento. A indução da anestesia ou sedação, após ingestão da solução de contraste pode trazer risco substancial para a broncoaspiração do conteúdo gástrico. Isto faz com que se opte por administrar o contraste por sonda gástrica após a intubação traqueal, uma vez que não se conhece o tempo de esvaziamento gástrico após utilização de solução contrastante. Esta conduta representa aumento do tempo de anestesia, o que resulta em constante questionamento sobre a possibilidade de esvaziamento do conteúdo gástrico em tempo inferior a uma hora. Seis casos de pacientes submetidos à tomografia de abdômen foram avaliados quanto ao esvaziamento gástrico por meio da realização de cortes tomográficos na topografia do estômago, com o objetivo de determinar a presença ou ausência de conteúdo residual líquido nesse órgão, após a administração da solução de contraste. RELATO DOS CASOS: Foram avaliadas seis crianças submetidas à tomografia contrastada do abdômen. Duas, não anestesiadas, apresentaram expressivo resíduo líquido gástrico decorridos 50 e 45 minutos, respectivamente, da ingestão de contraste. Quatro, submetidas à anestesia geral, também apresentaram resíduo líquido gástrico decorridos 40 a 50 minutos da administração de contraste via sonda oro/nasogástrica. Em duas destas persistiu apreciável resíduo líquido no estômago, mesmo após a aspiração do conteúdo pela sonda. CONCLUSÕES: Nos casos observados, o período de 40 a 50 minutos foi insuficiente para o esvaziamento do

  9. Anisotropic contrast optical microscope.

    Science.gov (United States)

    Peev, D; Hofmann, T; Kananizadeh, N; Beeram, S; Rodriguez, E; Wimer, S; Rodenhausen, K B; Herzinger, C M; Kasputis, T; Pfaunmiller, E; Nguyen, A; Korlacki, R; Pannier, A; Li, Y; Schubert, E; Hage, D; Schubert, M

    2016-11-01

    An optical microscope is described that reveals contrast in the Mueller matrix images of a thin, transparent, or semi-transparent specimen located within an anisotropic object plane (anisotropic filter). The specimen changes the anisotropy of the filter and thereby produces contrast within the Mueller matrix images. Here we use an anisotropic filter composed of a semi-transparent, nanostructured thin film with sub-wavelength thickness placed within the object plane. The sample is illuminated as in common optical microscopy but the light is modulated in its polarization using combinations of linear polarizers and phase plate (compensator) to control and analyze the state of polarization. Direct generalized ellipsometry data analysis approaches permit extraction of fundamental Mueller matrix object plane images dispensing with the need of Fourier expansion methods. Generalized ellipsometry model approaches are used for quantitative image analyses. These images are obtained from sets of multiple images obtained under various polarizer, analyzer, and compensator settings. Up to 16 independent Mueller matrix images can be obtained, while our current setup is limited to 11 images normalized by the unpolarized intensity. We demonstrate the anisotropic contrast optical microscope by measuring lithographically defined micro-patterned anisotropic filters, and we quantify the adsorption of an organic self-assembled monolayer film onto the anisotropic filter. Comparison with an isotropic glass slide demonstrates the image enhancement obtained by our method over microscopy without the use of an anisotropic filter. In our current instrument, we estimate the limit of detection for organic volumetric mass within the object plane of ≈49 fg within ≈7 × 7 μm 2 object surface area. Compared to a quartz crystal microbalance with dissipation instrumentation, where contemporary limits require a total load of ≈500 pg for detection, the instrumentation demonstrated here improves

  10. Phase Contrast Imaging

    DEFF Research Database (Denmark)

    1996-01-01

    The invention relates to a method and a system for synthesizing a prescribed intensity pattern based on phase contrast imaging that is not based on the assumption of prior art methods that the pahase shift phi is less than 1 radian. An improved method based on a simple imaging operation...... phasors attain predetermined values for predetermined spatial frequencies, and the phasor value of the specific resolution element of the spatial phase mask corresponds to a distinct intensity level of the image of the resolution element in the intensity pattern, and a spatial phase filter for phase...... shifting of a part of the electromagntic radiation, in combination with an imaging system for generation of the intensity pattern by interference in the image plane of the imaging system between the part of the electromagnetic raidation that has been phase shifted by the phase filter and the remaining part...

  11. A possible method using baseline hormonal levels to prescribe the appropriate oral therapeutic radioiodine dosage for Graves' disease

    International Nuclear Information System (INIS)

    Nakajo, Masayuki; Tsuchimochi, Shinsaku; Jinguji, Megumi; Tanabe, Hiroaki; Umanodan, Tomoichi; Nakabeppu, Yoshiaki

    2007-01-01

    The purpose of this study was to retrospectively examine the correlations of hormonal ratios with radioiodine I-131 therapeutic parameters and the potentiality of prescribing the therapeutic I-131 target dosage for an individual patient with Graves' disease using baseline serum levels of thyroid hormones. Serum T3, T4, and FT4 levels 6 and 12 months after I-131 therapy/baseline levels (hormonal ratios) were calculated for a total of 68 therapeutic courses in 57 patients with Graves' disease. The therapeutic parameters were absorbed dose (Gy), dose concentration (μCi/g) and oral dose (mCi). Linear regression analysis was performed for correlating hormonal ratios (X) and therapeutic parameters (Y). Significant (P<0.05) negative correlations of the hormonal ratios were observed with absorbed dose (R -0.50 for T3, -0.61 for T4, and -0.46 for FT4 at 6 months, and -0.29 for T3, -0.44 for T4 at 12 months) and dose concentration (R -0.57 for T3, -0.58 for T4, and -0.49 for FT4 at 6 months and -0.27 for T3, -0.27 for T4 at 12 months), but not with oral dose at 6 months and 12 months or the absorbed dose and dose concentration for FT4 at 12 months. The correlations were higher at 6 months than at 12 months and in serum T4 than in serum T3 and FT4. The formulae for serum T4 at 6 months were as follows: Y (Gy)=109-53X and Y (μCi/g)=109-52X. These results suggest that the hormonal ratios are significantly correlated with the absorbed dose and dose concentration. The formulae for serum T4 at 6 months may serve to prescribe the individual oral dosage for Graves' disease, although the correlation coefficients are about -0.6. (author)

  12. Contrast Invariant SNR

    DEFF Research Database (Denmark)

    Weiss, Pierre; Escande, Paul; Dong, Yiqiu

    We design an image quality measure independent of local contrast changes, which constitute simple models of illumination changes. Given two images, the algorithm provides the image closest to the first one with the component tree of the second. This problem can be cast as a specific convex progra...... algorithms based on interior point methods. The algorithm has potential applications in change detection, color image processing or image fusion. A Matlab implementation is available at http://www.math.univ-toulouse.fr/_weiss/PageCodes.html....

  13. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  14. Effect of Fixed Metallic Oral Appliances on Oral Health.

    Science.gov (United States)

    Alnazzawi, Ahmad

    2018-01-01

    There is a substantial proportion of the population using fixed metallic oral appliances, such as crowns and bridges, which are composed of various dental alloys. These restorations may be associated with a number of effects on oral health with variable degrees of severity, to review potential effects of using fixed metallic oral appliances, fabricated from various alloys. The MEDLINE/PubMed database was searched using certain combinations of keywords related to the topic. The search revealed that burning mouth syndrome, oral pigmentation, hypersensitivity and lichenoid reactions, and genotoxic and cytotoxic effects are the major potential oral health changes associated with fixed prosthodontic appliances. Certain oral disorders are associated with the use of fixed metallic oral appliances. Patch test is the most reliable method that can be applied for identifying metal allergy, and the simultaneous use of different alloys in the mouth is discouraged.

  15. Collection of Oral Fluids Using Cotton Ropes as a Sampling Method to Detect Foot-and-Mouth Disease Virus Infection in Pigs.

    Science.gov (United States)

    Vosloo, W; Morris, J; Davis, A; Giles, M; Wang, J; Nguyen, H T T; Kim, P V; Quach, N V; Le, P T T; Nguyen, P H N; Dang, H; Tran, H X; Vu, P P; Hung, V V; Le, Q T; Tran, T M; Mai, T M T; Le, Q T V; Singanallur, N B

    2015-10-01

    In high-density farming practices, it is important to constantly monitor for infectious diseases, especially diseases that have the potential to spread rapidly between holdings. Pigs are known to amplify foot-and-mouth disease (FMD) by excreting large amounts of virus, and it is therefore important to detect the virus quickly and accurately to minimize the spread of disease. Ropes were used to collect oral fluid samples from pigs, and each sample was compared to saliva samples collected from individual animals by detecting FMD virus RNA using real-time PCR. Two different experiments are described where groups of pigs were infected with different serotypes of FMD virus, either with or without vaccination, and unvaccinated pigs were kept in aerosol contact. The sensitivity of the rope sampling varied between 0.67 and 0.92, and the statistical agreement between this method and individual sampling ranged from substantial to moderate for the two different serotypes. The ease of collecting oral fluids using ropes together with the high sensitivity of subsequent FMD detection through PCR indicates that this could be a useful method to monitor pig populations for FMD virus infection. With further validation of the sensitivity of detection of FMD virus RNA, this can be a cost-effective, non-invasive diagnostic tool. © 2013 Blackwell Verlag GmbH.

  16. Fractal analysis in oral leukoplakia

    Directory of Open Access Journals (Sweden)

    Prashant Bhai Pandey

    2015-01-01

    Full Text Available Introduction: Fractal analysis (FA quantifies complex geometric structures by generating a fractal dimension (FD, which can measure the complexity of mucosa. FA is a quantitative tool used to measure the complexity of self-similar or semi-self-similar structures. Aim and Objective: The study was done to perform the FA of oral mucosa with keratotic changes, as it is also made up of self-similar tissues, and thus, its FD can be calculated. Results: In oral leukoplakia, keratinization increases the complexity of mucosa, which denotes fractal geometry. We evaluated and compared pretreated and post-treated oral leukoplakia in 50 patients with clinically proven oral leukoplakia and analyzed the normal oral mucosa and lesional or keratinized mucosa in oral leukoplakia patients through FA using box counting method. Conclusion: FA using the fractal geometry is an efficient, noninvasive prediction tool for early detection of oral leukoplakia and other premalignant conditions in patients.

  17. Sensitive, automatic method for the determination of diazepam and its five metabolites in human oral fluid by online solid-phase extraction and liquid chromatography with tandem mass spectrometry

    DEFF Research Database (Denmark)

    Jiang, Fengli; Rao, Yulan; Wang, Rong

    2016-01-01

    A novel and simple online solid-phase extraction liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of diazepam and its five metabolites including nordazepam, oxazepam, temazepam, oxazepam glucuronide, and temazepam glucuronide...... in human oral fluid. Human oral fluid was obtained using the Salivette(®) collection device, and 100 μL of oral fluid samples were loaded onto HySphere Resin GP cartridge for extraction. Analytes were separated on a Waters Xterra C18 column and quantified by liquid chromatography with tandem mass...

  18. Vaccination of commercial broiler chicks against avian metapneumovirus infection: a comparison of drinking-water, spray and oculo-oral delivery methods.

    Science.gov (United States)

    Ganapathy, Kannan; Bufton, Andrew; Pearson, Andrew; Lemiere, Stephane; Jones, Richard C

    2010-05-21

    Avian metapneumovirus (aMPV) has become an important cause of viral respiratory infections in turkey and chickens. Live and inactivated vaccinations are available worldwide for prevention of disease and economic losses caused by this pathogen. The efficacy of these vaccines is vigorously tested under laboratory conditions prior to use in the field. In this study, a live subtype B aMPV vaccine was administered by spray, drinking water or oculo-oral methods to separate groups of broiler chicks under field conditions. Following this, the chicks were immediately transferred to separate rooms in an experimental isolation house, monitored and challenged with virulent subtype B aMPV. No clinical signs were recorded following the vaccination methods. In the oculo-oral vaccinated chicks, 40-60% of the birds were vaccine virus positive by RT-PCR. In addition, in comparison to other groups, statistically higher levels of aMPV ELISA antibodies were detected. After spray vaccination, the number of chicks positive for the vaccine virus increased gradually from 10% at one week to 30% by 3 weeks post vaccination. Following drinking water vaccination, 30% of chicks were aMPV positive at 1 week but negative by 3 weeks post vaccination. In both, spray and drinking water vaccinated groups, no ELISA antibodies were detected, but when challenged all chicks were protected against disease. At 5 days post challenge, 100% of chicks in the unvaccinated and those vaccinated by spray or drinking water routes but only 20% of the oculo-oral-vaccinated chicks were aMPV positive by RT-PCR. At 10 days post challenge, 10% of chicks in each group were aMPV RT-PCR positive. On challenge, all vaccinated chicks were protected against disease. It appears that when aMPV vaccine is accurately applied to chicks by spray or drinking water routes, both are capable of giving protection against clinical disease equal to that induced in those chicks vaccinated individually by the oculo-oral route. Copyright 2010

  19. A novel effective method for the assessment of microvascular function in male patients with coronary artery disease: a pilot study using laser speckle contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Borges, J.P. [Laboratório de Atividade Física e Promoção è Saúde, Departamento de Desporto Coletivo, Instituto de Educação Física e Desportos, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ (Brazil); Lopes, G.O. [Laboratório de Atividade Física e Promoção è Saúde, Departamento de Desporto Coletivo, Instituto de Educação Física e Desportos, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ (Brazil); Instituto Nacional de Cardiologia, Rio de Janeiro, RJ (Brazil); Verri, V.; Coelho, M.P.; Nascimento, P.M.C.; Kopiler, D.A. [Instituto Nacional de Cardiologia, Rio de Janeiro, RJ (Brazil); Tibirica, E. [Instituto Nacional de Cardiologia, Rio de Janeiro, RJ (Brazil); Laboratório de Investigação Cardiovascular, Departamento Osório de Almeida, Instituto Oswaldo Cruz, FIOCRUZ, Rio de Janeiro, RJ (Brazil)

    2016-09-01

    Evaluation of microvascular endothelial function is essential for investigating the pathophysiology and treatment of cardiovascular and metabolic diseases. Although laser speckle contrast imaging technology is well accepted as a noninvasive methodology for assessing microvascular endothelial function, it has never been used to compare male patients with coronary artery disease with male age-matched healthy controls. Thus, the aim of this study was to determine whether laser speckle contrast imaging could be used to detect differences in the systemic microvascular functions of patients with established cardiovascular disease (n=61) and healthy age-matched subjects (n=24). Cutaneous blood flow was assessed in the skin of the forearm using laser speckle contrast imaging coupled with the transdermal iontophoretic delivery of acetylcholine and post-occlusive reactive hyperemia. The maximum increase in skin blood flow induced by acetylcholine was significantly reduced in the cardiovascular disease patients compared with the control subjects (74 vs 116%; P<0.01). With regard to post-occlusive reactive hyperemia-induced vasodilation, the patients also presented reduced responses compared to the controls (0.42±0.15 vs 0.50±0.13 APU/mmHg; P=0.04). In conclusion, laser speckle contrast imaging can identify endothelial and microvascular dysfunctions in male individuals with cardiovascular disease. Thus, this technology appears to be an efficient non-invasive technique for evaluating systemic microvascular and endothelial functions, which could be valuable as a peripheral marker of atherothrombotic diseases in men.

  20. A novel effective method for the assessment of microvascular function in male patients with coronary artery disease: a pilot study using laser speckle contrast imaging

    International Nuclear Information System (INIS)

    Borges, J.P.; Lopes, G.O.; Verri, V.; Coelho, M.P.; Nascimento, P.M.C.; Kopiler, D.A.; Tibirica, E.

    2016-01-01

    Evaluation of microvascular endothelial function is essential for investigating the pathophysiology and treatment of cardiovascular and metabolic diseases. Although laser speckle contrast imaging technology is well accepted as a noninvasive methodology for assessing microvascular endothelial function, it has never been used to compare male patients with coronary artery disease with male age-matched healthy controls. Thus, the aim of this study was to determine whether laser speckle contrast imaging could be used to detect differences in the systemic microvascular functions of patients with established cardiovascular disease (n=61) and healthy age-matched subjects (n=24). Cutaneous blood flow was assessed in the skin of the forearm using laser speckle contrast imaging coupled with the transdermal iontophoretic delivery of acetylcholine and post-occlusive reactive hyperemia. The maximum increase in skin blood flow induced by acetylcholine was significantly reduced in the cardiovascular disease patients compared with the control subjects (74 vs 116%; P<0.01). With regard to post-occlusive reactive hyperemia-induced vasodilation, the patients also presented reduced responses compared to the controls (0.42±0.15 vs 0.50±0.13 APU/mmHg; P=0.04). In conclusion, laser speckle contrast imaging can identify endothelial and microvascular dysfunctions in male individuals with cardiovascular disease. Thus, this technology appears to be an efficient non-invasive technique for evaluating systemic microvascular and endothelial functions, which could be valuable as a peripheral marker of atherothrombotic diseases in men

  1. Oral leukoplakia

    DEFF Research Database (Denmark)

    Holmstrup, Palle; Dabelsteen, Erik

    2016-01-01

    The idea of identifying oral lesions with a precancerous nature, i.e. in the sense of pertaining to a pathologic process with an increased risk for future malignant development, of course is to prevent frank malignancy to occur in the affected area. The most common oral lesion with a precancerous...... nature is oral leukoplakia, and for decades it has been discussed how to treat these lesions. Various treatment modalities, such as systemic therapies and surgical removal, have been suggested. The systemic therapies tested so far include retinoids, extracts of green tea, inhibitors of cyclooxygenase-2...

  2. Metabolic Interactions between Bacteria and Fungi in Commensal Oral Biofilms

    OpenAIRE

    Lof, Marloes; Janus, Marleen M.; Krom, Bastiaan P.

    2017-01-01

    Oral health is more than just the absence of disease. The key to oral health is a diverse microbiome in an ecological balance. The oral microbiota is one of the most complex and diverse microbial communities in the human body. To maintain oral health, balance between the human host and the intrinsic microorganisms is essential. The healthy oral cavity is represented by a great microbial diversity, including both bacteria and fungi. The bacterial microbiome is very well studied. In contrast, f...

  3. Socioeconomic inequality in oral health behavior in Iranian children and adolescents by the Oaxaca-Blinder decomposition method: the CASPIAN- IV study.

    Science.gov (United States)

    Safiri, Saeid; Kelishadi, Roya; Heshmat, Ramin; Rahimi, Ali; Djalalinia, Shirin; Ghasemian, Anoosheh; Sheidaei, Ali; Motlagh, Mohammad Esmaeil; Ardalan, Gelayol; Mansourian, Morteza; Asayesh, Hamid; Sepidarkish, Mahdi; Qorbani, Mostafa

    2016-09-14

    The present study set to describe the socioeconomic inequality associated with oral hygiene behavior among Iranian pediatric population. A representative sample of 13486 school students aged 6-18 years was selected through multistage random cluster sampling method from urban and rural areas of 30 provinces in Iran. Principle Component Analyses (PCA) correlated variables summarized as socioeconomic status (SES). Association of independent variables with tooth brushing was assessed through logistic regression analysis. Decomposition of the gap in tooth brushing between the first and fifth SES quintiles was assessed using the counterfactual decomposition technique. To assess the relation between tooth brushing and each socioeconomic category, Concentration Index (C) and the slope index of inequality (SII) were used, representing the linear regression coefficient. The participation rate was 90.6 % (50.7 % boys and 75.6 % urban inhabitants). The mean age of participants was 12.47 ± 3.36 years. The frequency of tooth brushing increased across SES quintiles, prevalence of tooth brushing between the first and fifth quintile, under 20 % difference, increased from 58.22 (95 % CI: 56.24,60.20) to 78.61 (95 % CI: 77.00,80.24). Only 3 % of the difference is explained by the factors considered in the study, and 17 % remained unknown. Residence area, family size, and smoking status made a significant contribution to the gap between the first and last SE groups. Residence area [ -2.01 (95 % CI: -3.46, -0.55)] was along the maximum levels of gaps between SE categories. The findings revealed a socio-economic inequality in oral health behavior in Iranian children and adolescents. Also, factors influencing oral health are addressed to develop and implement complementary public health actions.

  4. In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT

    Science.gov (United States)

    Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F.; Gao, Dong-Wei

    2012-01-01

    Purpose: To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Materials and Methods: Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Results: Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase–enhanced CT scan simultaneously in a single examination. Conclusion: Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012 PMID:22778447

  5. Video fluoroscopic techniques for the study of Oral Food Processing

    Science.gov (United States)

    Matsuo, Koichiro; Palmer, Jeffrey B.

    2016-01-01

    Food oral processing and pharyngeal food passage cannot be observed directly from the outside of the body without instrumental methods. Videofluoroscopy (x-ray video recording) reveals the movement of oropharyngeal anatomical structures in two dimensions. By adding a radiopaque contrast medium, the motion and shape of the food bolus can be also visualized, providing critical information about the mechanisms of eating, drinking, and swallowing. For quantitative analysis of the kinematics of oral food processing, radiopaque markers are attached to the teeth, tongue or soft palate. This approach permits kinematic analysis with a variety of textures and consistencies, both solid and liquid. Fundamental mechanisms of food oral processing are clearly observed with videofluoroscopy in lateral and anteroposterior projections. PMID:27213138

  6. Oral cancer.

    Science.gov (United States)

    Gerson, S J

    1990-01-01

    In the U.S. oral cancer accounts for 2.1% of all cancers and 1% of cancer deaths. Two to three times as many males as females are affected. Blacks have more intra-oral cancer than whites, and their incidence and mortality rates have increased in recent years. The etiologic process very likely involves several factors. The major etiologic agents are tobacco (all types) and alcoholic beverages. Herpes simplex virus, human papilloma virus, and Candida have been implicated. Host factors include poor state of dentition, nutritional aberrations, cirrhosis of liver, lichen planus, and immunologic impairmant. Cellular changes include amplification of some oncogenes, alterations in antigen expression, production of gamma-glutamyl transpeptidase, and disturbance of keratin and involucrin production. Experimentally, cancer is readily produced on the hamster cheek pouch and rat oral mucosa. Unlike oral cancer in humans, most experimental lesions are exophytic, and they rarely metastasize.

  7. Oral sex.

    Science.gov (United States)

    1996-04-05

    The Gay and Lesbian Medical Association urges HIV prevention specialists to regard male-to-male oral-genital sex as a low-risk activity and concentrate instead on the danger of unprotected anal intercourse. According to the association, the confusion and mixed messages surrounding oral sex are harming efforts to encourage gay men to make rational choices about truly risky behavior. The recommendations appear in the association's position paper issued March 19, 1996.

  8. Oral Cancer Screening

    Science.gov (United States)

    ... decrease the risk of oral cavity and oropharyngeal cancer. Oral cavity, pharyngeal, and laryngeal cancer are diseases in ... and treatment of oral cavity, pharyngeal, and laryngeal cancer: Oral Cavity and Oropharyngeal Cancer Prevention Lip and Oral ...

  9. Evaluation of living liver transplant donors: method for precise anatomic definition by using a dedicated contrast-enhanced MR imaging protocol.

    Science.gov (United States)

    Sahani, Dushyant; D'souza, Roy; Kadavigere, Rajagopal; Hertl, Martin; McGowan, Jennifer; Saini, Sanjay; Mueller, Peter R

    2004-01-01

    Liver transplantation from a living donor involves removal of part of the donor liver in a fashion that does not endanger its vascular supply or metabolic function. The radiologist plays an important role in evaluation of the living donor to define the conditions under which graft donation is contraindicated and to identify anatomic variations that may alter the surgical approach. In the past, diagnostic work-up of the donor involved costly and invasive tests. Currently, dynamic contrast material-enhanced computed tomography and magnetic resonance (MR) imaging are the imaging tests performed, each of which has advantages and limitations. MR imaging performed with liver-specific and extravascular contrast agents may be used as a single imaging test for comprehensive noninvasive evaluation of living liver transplant donors. MR imaging provides valuable information about variations in the vascular and biliary anatomy and allows evaluation of the hepatic parenchyma for diffuse or focal abnormalities. Copyright RSNA, 2004

  10. The association between use of metformin and change in serum CO_2 level after administration of contrast medium

    International Nuclear Information System (INIS)

    Kim, S.K.; Jung, J.; Jung, J.H.; Kim, K.Y.; Baek, J.-H.; Hahm, J.R.

    2016-01-01

    Aim: To evaluate the changes in serum creatinine and total CO_2 levels in patients receiving metformin during administration of contrast medium. Materials and methods: Patient records from January 2012 to December 2012 after the administration of contrast medium were reviewed retrospectively. A total of 924 patients were included for the final analysis. Of them, 105 received metformin during contrast medium administration, 112 were taking other oral hypoglycaemic agents, and 707 patients were not diabetic (controls). Results: No significant change in total CO_2 levels was detected (p=0.678). Metabolic acidosis was present in 33 (31.4%) metformin users, 31 (28.6%) other oral hypoglycaemic agent users, and 153 (21.6%) control patients. In the present logistic regression analysis, age, baseline levels of creatinine, and total CO_2 levels were associated with metabolic acidosis after contrast medium exposure. Conclusion: These data indicate the presence of a coexisting risk factor, other than metformin use, associated with metabolic acidosis after contrast medium exposure. No relationship was found between the use of metformin and metabolic acidosis during contrast medium exposure. - Highlights: • The use of metformin was not associated with metabolic acidosis after contrast exposure. • The coexisting risk factors for metabolic acidosis were present in patient with metabolic acidosis after contrast exposure. • There is a need to consider the maintenance of metformin during a CT scan in patients with a low risk for lactic acidosis.

  11. Effect of Emulsification Method and Particle Size on the Rate of in vivo Oral Bioavailability of Kenaf (Hibiscus cannabinus L.) Seed Oil.

    Science.gov (United States)

    Cheong, Ai Mun; Tan, Chin Ping; Nyam, Kar Lin

    2018-05-26

    Kenaf (Hibiscus cannabinus L.) seed oil-in-water nanoemulsions stabilized by complexation of beta-cyclodextrin with sodium caseinate and Tween 20 have been shown to have higher bioaccessibility of vitamin E and total phenolic content than nonemulsified kenaf seed oil in the previous in vitro gastrointestinal digestion study. However, its oral bioavailability was unknown. Therefore, the aim of this study was to evaluate the rate of in vivo oral bioavailability of kenaf seed oil-in-water nanoemulsions in comparison with nonemulsified kenaf seed oil and kenaf seed oil macroemulsions during the 180 min of gastrointestinal digestion. Kenaf seed oil macroemulsions were produced by using conventional method. Kenaf seed oil-in-water nanoemulsions had shown improvement in the rate of absorption. At 180 min of digestion time, the total α-tocopherol bioavailability of kenaf seed oil nanoemulsions was increased by 1.7- and 1.4-fold, compared to kenaf seed oil and macroemulsion, respectively. Kenaf seed oil-in-water nanoemulsions were stable in considerably wide range of pH (>5 and oil-in-water nanoemulsions had provided a delivery system to encapsulate the kenaf seed oil, as well as enhanced the bioaccessibility and bioavailability of kenaf seed oil. Therefore, kenaf seed oil-in-water nanoemulsions exhibit a great potential application in nutraceutical fields. © 2018 Institute of Food Technologists®.

  12. Quantitative evaluation of a single-distance phase-retrieval method applied on in-line phase-contrast images of a mouse lung

    International Nuclear Information System (INIS)

    Mohammadi, Sara; Larsson, Emanuel; Alves, Frauke; Dal Monego, Simeone; Biffi, Stefania; Garrovo, Chiara; Lorenzon, Andrea; Tromba, Giuliana; Dullin, Christian

    2014-01-01

    Quantitative analysis concerning the application of a single-distance phase-retrieval algorithm on in-line phase-contrast images of a mouse lung at different sample-to-detector distances is presented. Propagation-based X-ray phase-contrast computed tomography (PBI) has already proven its potential in a great variety of soft-tissue-related applications including lung imaging. However, the strong edge enhancement, caused by the phase effects, often hampers image segmentation and therefore the quantitative analysis of data sets. Here, the benefits of applying single-distance phase retrieval prior to the three-dimensional reconstruction (PhR) are discussed and quantified compared with three-dimensional reconstructions of conventional PBI data sets in terms of contrast-to-noise ratio (CNR) and preservation of image features. The PhR data sets show more than a tenfold higher CNR and only minor blurring of the edges when compared with PBI in a predominately absorption-based set-up. Accordingly, phase retrieval increases the sensitivity and provides more functionality in computed tomography imaging

  13. Simultaneous quantification of flavonoids in blood plasma by a high-performance liquid chromatography method after oral administration of Blumea balsamifera leaf extracts in rats.

    Science.gov (United States)

    Nessa, Fazilatun; Ismail, Zhari; Mohamed, Nornisah; Karupiah, Sundram

    2013-03-01

    The leaves of Blumea balsamifera are used as a folk medicine in kidney stone diseases in South-East Asia. Phytochemical investigation revealed leaves contained a number of flavonoids. In view of these, the present work was aimed to quantify and preliminary pharmacokinetic investigation of five flavonoids viz. dihydroquercetin-7,4¢-dimethyl ether (I), dihydroquercetin-4¢-methyl ether (II), 5,7,3¢,5¢-tetrahydroxyflavanone (III), blumeatin (IV) and quercetin (V) in rat plasma following oral administration (0.5g/Kg) of B. balsamifera leaf extract in rats. Quantification was achieved by using a validated, reproducible high-performance liquid chromatographic method. The mean recoveries of I, II, III, IV and V were 90.6, 93.4, 93.5, 91.2 and 90.3% respectively. The limit of quantification was 25 ng/mL for I and IV, 10 ng/mL for II and III and 100 ng/mL for V respectively. The within day and day-to-day precision for all the compounds were HPLC method herein was applied for pharmacokinetic studies and the main pharmacokinetic parameters were: t1/2 (hr) 5.8, 4.3, 2.9, 5.7 and 7.3, Cmax (ng/mL) 594.9, 1542.9 1659.9, 208.9 and 3040.4; Tmax (hr) 4.7, 1.0, 1.0, 3.5 and 2.3; AUC0-oo (ng hr/mL) 5040, 5893, 9260, 1064 and 27233 for I, II, III, IV and V respectively. The developed method was suitable for pharmacokinetic studies and this preliminary study also revealed significant absorption after oral dosing in rats.

  14. Oral Lichen Planus.

    Science.gov (United States)

    Ion, Daniela I; Setterfield, Jane F

    2016-02-01

    Lichen planus (LP) is a relatively common autoimmune T-cell-mediated disease of unknown aetiology affecting the mucous membranes, skin and nails. Its prevalence varies between 0.5 and 2.2% of the population in epidemiological studies with a peak incidence in the 30-60 years range and with a female predominance of 2:1. Mucosal lichen planus tends to follow a chronic course with acute exacerbations. Spontaneous remission of oral lichen planus (OLP) is uncommon, and indeed mucosal LP may become worse with time. In contrast, cutaneous lichen planus may follow a milder clinical course though some variants may be severe such as those affecting the palms and soles and the scalp and the genital tract in females (vulvovaginal gingival LP) where scarring leads to significant complications. It is important to identify those cases that may be drug induced or be associated with a contact allergic or irritant reaction (lichenoid reaction) or the rarer oral presentation of discoid lupus erythematosus. There is a very small risk of malignancy (approximately 1:200 patients/year) associated with oral lichen planus; thus patients should be informed that long term monitoring via their general dental practitioner is appropriate. This review will focus on the clinical presentation and management of oral lichen planus.

  15. Oral vs. salivary diagnostics

    Science.gov (United States)

    Marques, Joana; Corby, Patricia M.; Barber, Cheryl A.; Abrams, William R.; Malamud, Daniel

    2015-05-01

    The field of "salivary diagnostics" includes studies utilizing samples obtained from a variety of sources within the oral cavity. These samples include; whole unstimulated saliva, stimulated whole saliva, duct saliva collected directly from the parotid, submandibular/sublingual glands or minor salivary glands, swabs of the buccal mucosa, tongue or tonsils, and gingival crevicular fluid. Many publications state "we collected saliva from subjects" without fully describing the process or source of the oral fluid. Factors that need to be documented in any study include the time of day of the collection, the method used to stimulate and collect the fluid, and how much fluid is being collected and for how long. The handling of the oral fluid during and post-collection is also critical and may include addition of protease or nuclease inhibitors, centrifugation, and cold or frozen storage prior to assay. In an effort to create a standard protocol for determining a biomarker's origin we carried out a pilot study collecting oral fluid from 5 different sites in the mouth and monitoring the concentrations of pro- and anti-inflammatory cytokines detected using MesoScaleDiscovery (MSD) electrochemiluminesence assays. Our data suggested that 3 of the cytokines are primarily derived from the submandibular gland, while 7 of the cytokines come from a source other than the major salivary glands such as the minor salivary glands or cells in the oral mucosae. Here we review the literature on monitoring biomarkers in oral samples and stress the need for determining the blood/saliva ratio when a quantitative determination is needed and suggest that the term oral diagnostic be used if the source of an analyte in the oral cavity is unknown.

  16. Polymer adhesion predictions for oral dosage forms to enhance drug administration safety. Part 2: In vitro approach using mechanical force methods.

    Science.gov (United States)

    Drumond, Nélio; Stegemann, Sven

    2018-06-01

    Predicting the potential for unintended adhesion of solid oral dosage forms (SODF) to mucosal tissue is an important aspect that should be considered during drug product development. Previous investigations into low strength mucoadhesion based on particle interactions methods provided evidence that rheological measurements could be used to obtain valid predictions for the development of SODF coatings that can be safely swallowed. The aim of this second work was to estimate the low mucoadhesive strength properties of different polymers using in vitro methods based on mechanical forces and to identify which methods are more precise when measuring reduced mucoadhesion. Another aim was to compare the obtained results to the ones achieved with in vitro particle interaction methods in order to evaluate which methodology can provide stronger predictions. The combined results correlate between particle interaction methods and mechanical force measurements. The polyethylene glycol grades (PEG) and carnauba wax showed the lowest adhesive potential and are predicted to support safe swallowing. Hydroxypropyl methylcellulose (HPMC) along with high molecular grades of polyvinylpyrrolidone (PVP) and polyvinyl alcohol (PVA) exhibited strong in vitro mucoadhesive strength. The combination of rheological and force tensiometer measurements should be considered when assessing the reduced mucoadhesion of polymer coatings to support safe swallowing of SODF. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  18. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me...

  19. Generalized phase contrast:

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Palima, Darwin

    Generalized Phase Contrast elevates the phase contrast technique not only to improve phase imaging but also to cross over and interface with diverse and seemingly disparate fields of contemporary optics and photonics. This book presents a comprehensive introduction to the Generalized Phase Contrast...

  20. Users of withdrawal method in the Islamic Republic of Iran: are they intending to use oral contraceptives? Applying the theory of planned behaviour.

    Science.gov (United States)

    Rahnama, P; Hidarnia, A; Shokravi, F A; Kazemnejad, A; Montazeri, A; Najorkolaei, F R; Saburi, A

    2013-09-01

    Many couples in the Islamic Republic of Iran rely on coital withdrawal for contraception. The purpose of this cross-sectional study was to use the theory of planned behaviour to explore factors that influence withdrawal users' intent to switch to oral contraception (OC). Participants were 336 sexually active, married women, who were current users of withdrawal and were recruited from 5 public family planning clinics in Tehran. A questionnair included measures of the theory of planned behaviour: attitude (behavioural beliefs, outcome evaluations), subjective norms (normative beliefs, motivation to comply), perceived behaviour control, past behaviour and behavioural intention. Linear regression analyses showed that past behaviour, perceived behaviour control, attitude and subjective norms accounted for the highest percentage of total variance observed for intention to use OC (36%). Beliefs-based family planning education and counsellingshould to be designed for users of the withdrawal method.

  1. Evaluation of contrast reproduction method based on the anatomical guidance of the cerebral images reconstruction in positron emission tomography; Evaluation d'une methode de restitution de contraste basee sur le guidage anatomique de la reconstruction des images cerebrales en tomographie par emission de positons

    Energy Technology Data Exchange (ETDEWEB)

    Bataille, F

    2007-04-15

    Positron emission tomography is a medical imaging modality providing in-vivo volumetric images of functional processes of the human body, which is used for the diagnosis and the following of neuro degenerative diseases. PET efficiency is however limited by its poor spatial resolution, which generates a decrease of the image local contrast and leads to an under-estimation of small cerebral structures involved in the degenerative mechanism of those diseases. This so-called partial volume effect degradation is usually corrected in a post-reconstruction processing framework through the use of anatomical information, whose spatial resolution allows a better discrimination between functional tissues. However, this kind of method has the major drawback of being very sensitive to the residual mismatches on the anatomical information processing. We developed in this thesis an alternative methodology to compensate for the degradation, by incorporating in the reconstruction process both a model of the system impulse response and an anatomically-based image prior constraint. This methodology was validated by comparison with a post-reconstruction correction strategy, using data from an anthropomorphic phantom acquisition and then we evaluated its robustness to the residual mismatches through a realistic Monte Carlo simulation corresponding to a cerebral exam. The proposed algorithm was finally applied to clinical data reconstruction. (author)

  2. Evaluation of contrast reproduction method based on the anatomical guidance of the cerebral images reconstruction in positron emission tomography; Evaluation d'une methode de restitution de contraste basee sur le guidage anatomique de la reconstruction des images cerebrales en tomographie par emission de positons

    Energy Technology Data Exchange (ETDEWEB)

    Bataille, F

    2007-04-15

    Positron emission tomography is a medical imaging modality providing in-vivo volumetric images of functional processes of the human body, which is used for the diagnosis and the following of neuro degenerative diseases. PET efficiency is however limited by its poor spatial resolution, which generates a decrease of the image local contrast and leads to an under-estimation of small cerebral structures involved in the degenerative mechanism of those diseases. This so-called partial volume effect degradation is usually corrected in a post-reconstruction processing framework through the use of anatomical information, whose spatial resolution allows a better discrimination between functional tissues. However, this kind of method has the major drawback of being very sensitive to the residual mismatches on the anatomical information processing. We developed in this thesis an alternative methodology to compensate for the degradation, by incorporating in the reconstruction process both a model of the system impulse response and an anatomically-based image prior constraint. This methodology was validated by comparison with a post-reconstruction correction strategy, using data from an anthropomorphic phantom acquisition and then we evaluated its robustness to the residual mismatches through a realistic Monte Carlo simulation corresponding to a cerebral exam. The proposed algorithm was finally applied to clinical data reconstruction. (author)

  3. Irradiation mucositis and oral flora

    International Nuclear Information System (INIS)

    Spijkervet, F.K.L.

    1989-01-01

    This study, which is motivated by the substantial morbidity of local signs of mucositis and generalized symptoms that result from mucositis induced by therapeutic irradiation, has the following objectives: To investigate if it is possible to prevent irradiation mucositis via oral flora elimination, and, if it is true that flora plays a role in irradiation mucositis, what fraction of the oral flora may be involved; to evaluate oral Gram-negative bacillary carriage; to investigate the possibility to eradicate Gram-negative bacilli from the oral cavity; to evaluate oral yeast carriage; to investigate the possibility to eradicate yeasts stomatitis and the 'selectivity' of elimination of flora. Two methods are described for monitoring alterations of mucositis of the oral cavity and changes in oral flora. Chlorhexidine has been tested as the commonly used prophylaxis. The effect of chlorhexidine 0.1% rinses on oral flora and mucositis has been studied in a prospective placebo controlled double blind randomized programme. The results of the influence of saliva on the antimicrobial activity of chlorhexidine and the results of selective elimination of oral flora in irradiated patients who have head and neck cancer are reported. Salivary inactivation of the topical antimicrobials used for selective elimination of oral flora has been studied and the results are reported. Finally, the objectives that have been achieved (or not) are delineated. The significance of the results of the study are discussed in terms of published information and further lines of research are suggested. (author). 559 refs.; 29 figs.; 20 tabs

  4. Early diagnosis of adenylosuccinate lyase deficiency using a high-throughput screening method and a trial of oral S-adenosyl-l-methionine as a treatment method.

    Science.gov (United States)

    van Werkhoven, Michiel A; Duley, John A; McGown, Ivan; Munce, Teresa; Freeman, Jeremy L; Pitt, James J

    2013-11-01

    The aim of this study was to develop a high-throughput urine screening technique for adenylosuccinate lyase (ADSL) deficiency and to evaluate S-adenosyl-l-methionine (SAMe) as a potential treatment for this disorder. Testing for succinyladenosine (S-Ado), a marker of ADSL deficiency, was incorporated into a screening panel for urine biomarkers for inborn errors of metabolism using electrospray tandem mass spectrometry. Liquid chromatography-mass spectrometry and high-performance liquid chromatography were used to confirm and monitor the response of metabolites to oral SAMe treatment. Increased levels of S-Ado were detected in a 3-month-old male infant with hypotonia and seizures. ADSL gene sequencing revealed a previously described c.-49T>C mutation and a novel c.889_891dupAAT mutation, which was likely to disrupt enzyme function. After 9 months of SAMe treatment, there was no clear response evidenced in urine metabolite levels or clinical parameters. These results demonstrate proof of the principle for the high-throughput urine screening technique, allowing earlier diagnosis of patients with ADSL deficiency. However, early treatment with SAMe does not appear to be effective in ADSL deficiency. It is suggested that although SAMe treatment may ameliorate purine nucleotide deficiency, it cannot correct metabolic syndromes in which a toxic nucleotide is present, in this case presumed to be succinylaminoimidazole carboxamide ribotide. © 2013 Mac Keith Press.

  5. Print and online newspaper coverage of the link between HPV and oral cancer in the UK: a mixed-methods study

    Science.gov (United States)

    Dodd, Rachael H; Marlow, Laura A V; Forster, Alice S; Waller, Jo

    2016-01-01

    Objectives The role of human papillomavirus (HPV) in some oral cancers has been reported in the news press, though little is known about the content of these articles. This study aimed to examine how frequently the link between HPV and oral cancer has been reported in the news press and to examine the content of these articles. Design UK media articles were searched for articles relating to oral cancer and HPV in the database NexisUK. Of 854 articles identified by the initial search, 112 were eligible for inclusion (2002–2014) and content analysis was used to determine the main themes discussed. Results Themes included actor Michael Douglas’ claim that his throat cancer was caused by HPV, the riskiness of oral sex, health information (including HPV as a cause of oral cancer) and the need to vaccinate boys against HPV. Many articles also referred to the link between HPV and cervical cancer and the increasing incidence of HPV-related oral cancer. The largest peak in articles occurred when Michael Douglas discussed his cancer (June 2013). Facts about HPV and references to research were provided in some articles. Conclusions The link between HPV and oral cancer and the transmission of HPV via oral sex was regularly discussed, yet coverage often lacked detailed health information. This could increase awareness of the link between oral sex and HPV risk, but may also lead to public concern about oral sex as a sexual behaviour. PMID:26920439

  6. Perforations during contrast enema

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.; Grabbe, E.; Allgemeines Krankenhaus Ochsenzoll, Hamburg

    1983-01-01

    During contrast enema, perforation into the retroperitoneal space can be differentiated from perforation into the peritoneum and perforation into the intestinal wall associated with formation of barium granulomas or submucosal spreading of the contrast medium. Other special forms are perforation with contrast medium embolism of diverticula; of the processus vermiformis; penetration of contrast medium into fistulous systems and from the operated areas. Risk factors are: balloon catheter, intestinal tubes with a hard tip, preternatural anus, excessive enema pressure, contrast medium additions, preceding manipulations, intestinal diseases, advanced age and delegation of manipulations to assistants and unskilled staff. Children are particularly at risk. (orig.) [de

  7. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me....../min/1.73 m (2) is CIN risk threshold for intravenous contrast medium. • Hydration with either saline or sodium bicarbonate reduces CIN incidence. • Patients with eGFR = 60 ml/min/1.73 m (2) receiving contrast medium can continue metformin normally....

  8. Oral candidiasis.

    Science.gov (United States)

    Millsop, Jillian W; Fazel, Nasim

    2016-01-01

    Oral candidiasis (OC) is a common fungal disease encountered in dermatology, most commonly caused by an overgrowth of Candida albicans in the mouth. Although thrush is a well-recognized presentation of OC, it behooves clinicians to be aware of the many other presentations of this disease and how to accurately diagnose and manage these cases. The clinical presentations of OC can be broadly classified as white or erythematous candidiasis, with various subtypes in each category. The treatments include appropriate oral hygiene, topical agents, and systemic medications. This review focuses on the various clinical presentations of OC and treatment options. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Oral myiasis

    Directory of Open Access Journals (Sweden)

    Treville Pereira

    2010-01-01

    Full Text Available Myiasis is a relatively rare condition arising from the invasion of body tissues or cavities of living animals or humans by maggots or larvae of certain species of flies. It is an uncommon clinical condition, being more frequent in underdeveloped countries and hot climate regions, and is associated with poor hygiene, suppurative oral lesions; alcoholism and senility. Its diagnosis is made basically by the presence of larvae. The present article reports a case of oral myiasis involving 20 larvae in a patient with neurological deficiency.

  10. A novel validated stability indicating high performance liquid chromatographic method for estimation of degradation behavior of ciprofloxacin and tinidazole in solid oral dosage

    Directory of Open Access Journals (Sweden)

    Bhupendrasinh K Vaghela

    2013-01-01

    Full Text Available Objective: The objective of current investigation was to study the degradation behavior of Ciprofloxacin and Tinidazole. The study was performed as per International Conference on Harmonization recommended stress condition. A novel stability-indicating reverse phase HPLC method was developed for the determination of Ciprofloxacin and Tinidazole purity in the presence of its impurities and forced degradation products. This method is also capable to separate placebo peaks as well in pharmaceutical dosage forms. The solid oral dosage form was subjected to the stress conditions such as oxidative, acid, base hydrolysis, heat and photolytic degradation. Materials and Methods: The method was developed using Waters symmetry shield, Reverse Phase (RP C18, 250mm x 4.6mm, 5΅ as a stationary phase. The mobile phase containing a gradient mixture of solvent A and B. 10mM phosphate buffer, adjusted pH 3.0 with phosphoric acid was used as a buffer. Buffer pH 3.0 was used as solvent A and buffer pH 3.0: Acetonitrile in the ratio of 20: 80 v/v were used as solvent B. The eluted compounds were monitored 278 nm (Ciprofloxacin, 317 nm (Tinidazole. The run time was 50 minute. Results: In the precision study the % RSD for the result of Ciprofloxacin, Tinidazole and its impurities was below 10%. The method was linear with the correlation coefficient greater than 0.997. The percentage recoveries were calculated and observed from 93.0% to 106.7%.The peak purity of Ciprofloxacin, Tinidazole peak had not shown any flag, thus proved the stability-indicating power of the method. Conclusion: The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness.

  11. Deutsch Durch Audio-Visuelle Methode: An Audio-Lingual-Oral Approach to the Teaching of German.

    Science.gov (United States)

    Dickinson Public Schools, ND. Instructional Media Center.

    This teaching guide, designed to accompany Chilton's "Deutsch Durch Audio-Visuelle Methode" for German 1 and 2 in a three-year secondary school program, focuses major attention on the operational plan of the program and a student orientation unit. A section on teaching a unit discusses four phases: (1) presentation, (2) explanation, (3)…

  12. A novel and discriminative method of in vitro disintegration time for preparation and optimization of taste-masked orally disintegrating tablets of carbinoxamine maleate.

    Science.gov (United States)

    Liu, Yali; Li, Peng; Qian, Rong; Sun, Tianyu; Fang, Fangzhi; Wang, Zonghua; Ke, Xue; Xu, Bohui

    2018-08-01

    The primary objective of this study was to mask bitter taste and decrease the disintegration time of carbinoxamine maleate (CAM) orally disintegrating tablets (ODTs). In order to screen the prescription of ODTs, a novel modified in vitro disintegration method (MIVDM) was developed to measure the in vitro disintegration time. In this method, different concentrations of ethanol served as disintegration medium in order to delay the in vitro water absorption and disintegration process of tablets. The MIVDM demonstrated good in vitro and in vivo correlation and proved more precise and discriminative than other reported methods. In this research, ion exchange resins (IERs) were used to mask bitter taste for improving mouthfeel. The drug-resin ratio and reaction temperature were investigated to obtain the optimum carbinoxamine resin complexes (CRCs). The characterization of CRCs revealed an amorphous state. ODTs were prepared by direct compression. Superdisintegrants and diluents of ODTs were screened first. Further optimization was carried out by using Box-Behnken design. The effect of (X 1 ) mannitol/microcrystalline cellulose ratio, (X 2 ) the amount of low-substituted hydroxypropylcellulose and (X 3 ) the hardness was investigated for achieving the lowest (Y) in vitro disintegration time. Technological characterization, wetting time, water absorption ratio, and roughness degree were evaluated. The CRCs and ODTs proved successful taste-masking efficiency. The end product improved patients' compliance. The developed MIVDM was practical for commercial use.

  13. Oral bioaccessibility of semi-volatile organic compounds (SVOCs) in settled dust: A review of measurement methods, data and influencing factors.

    Science.gov (United States)

    Raffy, Gaëlle; Mercier, Fabien; Glorennec, Philippe; Mandin, Corinne; Le Bot, Barbara

    2018-06-15

    Many semi-volatile organic compounds (SVOCs), suspected of reprotoxic, neurotoxic or carcinogenic effects, were measured in indoor settled dust. Dust ingestion is a non-negligible pathway of exposure to some of these SVOCs, and an accurate knowledge of the real exposure is necessary for a better evaluation of health risks. To this end, the bioaccessibility of SVOCs in dust needs to be considered. In the present work, bioaccessibility measurement methods, SVOCs' oral bioaccessibility data and influencing factors were reviewed. SVOC bioaccessibilities (%) ranged from 11 to 94, 8 to 100, 3 to 92, 1 to 81, 6 to 52, and 2 to 17, for brominated flame retardants, organophosphorus flame retardants, polychlorobiphenyls, phthalates, pesticides and polycyclic aromatic hydrocarbons, respectively. Measurements method produced varying results depending on the inclusion of food and/or sink in the model. Characteristics of dust, e.g., organic matter content and particle size, also influenced bioaccessibility data. Last, results were influenced by SVOC properties, such as octanol/water partition coefficient and migration pathway into dust. Factors related to dust and SVOCs could be used in prediction models. To this end, more bioaccessibility studies covering more substances should be performed, using methods that are harmonized and validated by comparison to in-vivo studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Ultra high performance liquid chromatography-electrospray ionization-tandem mass spectrometry screening method for direct analysis of designer drugs, "spice" and stimulants in oral fluid.

    Science.gov (United States)

    Strano-Rossi, Sabina; Anzillotti, Luca; Castrignanò, Erika; Romolo, Francesco Saverio; Chiarotti, Marcello

    2012-10-05

    An ultra high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS) screening method for the direct analysis in oral fluid (OF) of 24 drugs, including new synthetic cannabinoids and so-called "smart" designer drugs, in a single chromatographic run was set up. Benzylpiperazine, methylone, 5,6-methylenedioxy-2-aminoindane (MDAI), fenproporex, 4-fluoroamphetamine (4-FA), 4-methyl-N-ethylcathinone (4-MEC), 4-methylamphetamine (4-MA), methylbenzodioxolylbutanamine (MBDB), mephedrone, methylthioamphetamine (MTA), methylenedioxypyrovalerone (MDPV), mefenorex, nabilone, furfenorex, clobenzorex, JWH-200, AM 694, JWH-250, JWH-073, JWH-018, JWH-019, JWH-122, HU 210 and CP 47497 were determined in a chromatographic run of 9 min only with no sample pre-treatment, after addition of ISs and dilution in mobile phase A. This method is designed to be applied to 250 μL of OF sample, anyway is suitable to be used on smaller volumes (till 100 μL). LODs vary from 1ng/mL to 20 ng/mL. No interfering peaks were observed due to similar analytes, common therapeutic drugs or endogenous compounds. Matrix effect, although present especially for mephedrone, is acceptable, allowing the detection of the compounds at the LODs described. The developed method was applied on 400 real OF samples from on-site tests performed by police officers. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Oral care.

    Science.gov (United States)

    Hitz Lindenmüller, Irène; Lambrecht, J Thomas

    2011-01-01

    Adequate dental and oral hygiene may become a challenge for all users and especially for elderly people and young children because of their limited motor skills. The same holds true for patients undergoing/recovering from chemo-/radiotherapy with accompanying sensitive mucosal conditions. Poor dental hygiene can result in tooth decay, gingivitis, periodontitis, tooth loss, bad breath (halitosis), fungal infection and gum diseases. The use of a toothbrush is the most important measure for oral hygiene. Toothbrushes with soft bristles operated carefully by hand or via an electric device help to remove plaque and to avoid mucosal trauma. A handlebar with a grip cover can be helpful for manually disabled patients or for those with reduced motor skills. In case of oral hygiene at the bedside or of patients during/after chemo-/radiotherapy a gauze pad can be helpful for gently cleaning the teeth, gums and tongue. The use of fluoride toothpaste is imperative for the daily oral hygiene. Detergents such as sodium lauryl sulphate improve the cleaning action but may also dehydrate and irritate the mucous membrane. The use of products containing detergents and flavouring agents (peppermint, menthol, cinnamon) should therefore be avoided by bedridden patients or those with dry mouth and sensitive mucosa. Aids for suitable interdental cleaning, such as dental floss, interdental brushes or dental sticks, are often complicated to operate. Their correct use should be instructed by healthcare professionals. To support dental care, additional fluoridation with a fluoride gel or rinse can be useful. Products further containing antiseptics such as chlorhexidine or triclosan reduce the quantity of bacteria in the mouth. For patients undergoing or having undergone radio-/chemotherapy, a mouthwash that concomitantly moisturizes the oral mucosa is advisable. Copyright © 2011 S. Karger AG, Basel.

  16. Dialysis and contrast media

    International Nuclear Information System (INIS)

    Morcos, Sameh K.; Thomsen, Henrik S.; Webb, Judith A.W.

    2002-01-01

    In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of dialysis membrane, duration of hemodialysis and molecular size, protein binding, hydrophilicity, and electrical charge of the contrast medium. Generally, several hemodialysis sessions are needed to removal all contrast medium, whereas it takes 3 weeks for continuous ambulatory dialysis to remove the agent completely. There is no need to schedule the dialysis in relation to the injection of iodinated or MR contrast media or the injection of contrast agent in relation to the dialysis program. Hemodialysis does not protect poorly functioning kidneys against contrast-medium-induced nephrotoxicity. Simple guidelines are given. (orig.)

  17. Oral Health and Aging

    Science.gov (United States)

    ... please turn JavaScript on. Feature: Oral Health and Aging Oral Health and Aging Past Issues / Summer 2016 Table of Contents Jerrold ... they may need. Read More "Oral Health and Aging" Articles Oral Health and Aging / 4 Myths About ...

  18. Accuracy of imaging methods for detection of bone tissue invasion in patients with oral squamous cell carcinoma

    Science.gov (United States)

    Uribe, S; Rojas, LA; Rosas, CF

    2013-01-01

    The objective of this review is to evaluate the diagnostic accuracy of imaging methods for detection of mandibular bone tissue invasion by squamous cell carcinoma (SCC). A systematic review was carried out of studies in MEDLINE, SciELO and ScienceDirect, published between 1960 and 2012, in English, Spanish or German, which compared detection of mandibular bone tissue invasion via different imaging tests against a histopathology reference standard. Sensitivity and specificity data were extracted from each study. The outcome measure was diagnostic accuracy. We found 338 articles, of which 5 fulfilled the inclusion criteria. Tests included were: CT (four articles), MRI (four articles), panoramic radiography (one article), positron emission tomography (PET)/CT (one article) and cone beam CT (CBCT) (one article). The quality of articles was low to moderate and the evidence showed that all tests have a high diagnostic accuracy for detection of mandibular bone tissue invasion by SCC, with sensitivity values of 94% (MRI), 91% (CBCT), 83% (CT) and 55% (panoramic radiography), and specificity values of 100% (CT, MRI, CBCT), 97% (PET/CT) and 91.7% (panoramic radiography). Available evidence is scarce and of only low to moderate quality. However, it is consistently shown that current imaging methods give a moderate to high diagnostic accuracy for the detection of mandibular bone tissue invasion by SCC. Recommendations are given for improving the quality of future reports, in particular provision of a detailed description of the patients' conditions, the imaging instrument and both imaging and histopathological invasion criteria. PMID:23420854

  19. A LC-MS-MS method for determination of low doxazosin concentrations in plasma after oral administration to dogs.

    Science.gov (United States)

    Erceg, Marijana; Cindric, Mario; Pozaic Frketic, Lidija; Vertzoni, Maria; Cetina-Cizmek, Biserka; Reppas, Christos

    2010-02-01

    A rapid and sensitive reversed phase liquid chromatography- tandem mass spectrometry (LC-MS-MS) method is developed for the determination of doxazosin in canine plasma. The samples are prepared by precipitation of proteins using a mixture of methanol and acetonitrile, followed by freezing and evaporation of the organic solvent. The remaining dry residue is redissolved in mobile phase and analyzed by LC-MS-MS with positive electrospray ionization using the selected reactions monitoring mode. An XTerra MS C(18) column, a mobile phase composed of acetonitrile and 2mM ammonium acetate with gradient elution, and a flow rate of 400 microL/min are employed. The elution times for prazosin (internal standard) and doxazosin are approximately 8 and 10 min, respectively. Calibration curves are linear in the 1-20 ng/mL concentration range. Limits of detection and quantification are 0.4 ng/mL and 1.2 ng/mL, respectively. Recovery is higher than 94%. Intra- and inter-day relative standard deviations are below 7% and 8%, respectively. The method is applied for the determination of doxazosin plasma levels following a single administration of doxazosin base and doxazosin mesylate tablets (2 mg dose) to dogs in the fed state. The results indicate possible superiority of the mesylate salt on the plasma input rates of doxazosin.

  20. Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Menk, Ralf Hendrik

    2008-01-01

    All standard (medical) x-ray imaging technologies, rely primarily on the amplitude properties of the incident radiation, and do not depend on its phase. This is unchanged since the discovery by Roentgen that the intensity of an x-ray beam, as measured by the exposure on a film, was related to the relative transmission properties of an object. However, recently various imaging techniques have emerged which depend on the phase of the x-rays as well as the amplitude. Phase becomes important when the beam is coherent and the imaging system is sensitive to interference phenomena. Significant new advances have been made in coherent optic theory and techniques, which now promise phase information in medical imaging. The development of perfect crystal optics and the increasing availability of synchrotron radiation facilities have contributed to a significant increase in the application of phase based imaging in materials and life sciences. Unique source characteristics such as high intensity, monochromaticity, coherence and high collimating provide an ideal source for advanced imaging. Phase contrast imaging has been applied in both projection and computed tomography modes, and recent applications have been made in the field of medical imaging. Due to the underlying principle of X-ray detection conventional image receptors register only intensities of wave fields and not their phases. During the last decade basically five different methods were developed that translate the phase information into intensity variations. These methods are based on measuring the phase shift φ directly (using interference phenomena), the gradient ∇ φ , or the Laplacian ∇ 2 φ. All three methods can be applied to polychromatic X-ray sources keeping in mind that the native source is synchrotron radiation, featuring monochromatic and reasonable coherent X-ray beams. Due to the vast difference in the coefficients that are driven absorption and phase effects (factor 1,000-10,000 in the energy

  1. On the Robustness and Prospects of Adaptive BDDC Methods for Finite Element Discretizations of Elliptic PDEs with High-Contrast Coefficients

    KAUST Repository

    Zampini, Stefano; Keyes, David E.

    2016-01-01

    Balancing Domain Decomposition by Constraints (BDDC) methods have proven to be powerful preconditioners for large and sparse linear systems arising from the finite element discretization of elliptic PDEs. Condition number bounds can be theoretically

  2. [Establishment of simultaneous measurement method of 8 salivary components using urinary test paper and clinical evaluation of oral environment].

    Science.gov (United States)

    Yuuki, Kenji; Tsukasaki, Hiroaki; Kawawa, Tadaharu; Shiba, Akihiko; Shiba, Kiyoko

    2008-07-01

    Clinical findings were compared with glucose, protein, albumin, bilirubin, creatinine, pH, occult blood, ketone body, nitrite, and white blood cells contained in whole saliva to investigate the components that most markedly reflect the periodontal condition. The subjects were staff of the Prosthodontics Department, Showa University, and patients who visited for dental treatments (57 subjects in total). At the first time, saliva samples were gargled with 1.5 ml of distilled water for 15 seconds and collected by spitting out into a paper cup. At the second time, saliva samples were collected by the same method. At the third time, saliva samples after chewing paraffin gum for 60 seconds were collected by spitting out into a paper cup. Thus whole saliva collecting that was divided on three times. After sampling, 8 mul of the saliva sample was dripped in reagent sticks for the 10 items of urinary test paper and the reflectance was measured using a specific reflectometer. In the periodontal tissue evaluation, the degree of alveolar bone resorption, probing value, and tooth mobility and the presence or absence of lesions in the root furcation were examined and classified into 4 ranks. The mean values in each periodontal disease rank and correlation between the periodontal disease ranks and the components were statistically analyzed. Bilirubin and ketone body were not measurable. The components density of the 8 items was increased as the periodontal disease rank increased. Regarding the correlation between the periodontal disease ranks and the components, high correlations were noted for protein, albumin, creatinine, pH, and white blood cells. The simultaneous measurement method of 8 salivary components using test paper may be very useful for the diagnosis of periodontal disease of abutment teeth.

  3. Contrast-guided image interpolation.

    Science.gov (United States)

    Wei, Zhe; Ma, Kai-Kuang

    2013-11-01

    In this paper a contrast-guided image interpolation method is proposed that incorporates contrast information into the image interpolation process. Given the image under interpolation, four binary contrast-guided decision maps (CDMs) are generated and used to guide the interpolation filtering through two sequential stages: 1) the 45(°) and 135(°) CDMs for interpolating the diagonal pixels and 2) the 0(°) and 90(°) CDMs for interpolating the row and column pixels. After applying edge detection to the input image, the generation of a CDM lies in evaluating those nearby non-edge pixels of each detected edge for re-classifying them possibly as edge pixels. This decision is realized by solving two generalized diffusion equations over the computed directional variation (DV) fields using a derived numerical approach to diffuse or spread the contrast boundaries or edges, respectively. The amount of diffusion or spreading is proportional to the amount of local contrast measured at each detected edge. The diffused DV fields are then thresholded for yielding the binary CDMs, respectively. Therefore, the decision bands with variable widths will be created on each CDM. The two CDMs generated in each stage will be exploited as the guidance maps to conduct the interpolation process: for each declared edge pixel on the CDM, a 1-D directional filtering will be applied to estimate its associated to-be-interpolated pixel along the direction as indicated by the respective CDM; otherwise, a 2-D directionless or isotropic filtering will be used instead to estimate the associated missing pixels for each declared non-edge pixel. Extensive simulation results have clearly shown that the proposed contrast-guided image interpolation is superior to other state-of-the-art edge-guided image interpolation methods. In addition, the computational complexity is relatively low when compared with existing methods; hence, it is fairly attractive for real-time image applications.

  4. Assessment of vegetation establishment on tailings dam at an iron ore mining site of suburban Beijing, China, 7 years after reclamation with contrasting site treatment methods.

    Science.gov (United States)

    Yan, Demin; Zhao, Fangying; Sun, Osbert Jianxin

    2013-09-01

    Strip-mining operations greatly disturb soil, vegetation and landscape elements, causing many ecological and environmental problems. Establishment of vegetation is a critical step in achieving the goal of ecosystem restora