WorldWideScience

Sample records for optical spectroscopic techniques

  1. Study of receptor-chaperone interactions using the optical technique of spectroscopic ellipsometry.

    Science.gov (United States)

    Kriechbaumer, Verena; Tsargorodskaya, Anna; Mustafa, Mohd K; Vinogradova, Tatiana; Lacey, Joanne; Smith, David P; Abell, Benjamin M; Nabok, Alexei

    2011-07-20

    This work describes a detailed quantitative interaction study between the novel plastidial chaperone receptor OEP61 and isoforms of the chaperone types Hsp70 and Hsp90 using the optical method of total internal reflection ellipsometry (TIRE). The receptor OEP61 was electrostatically immobilized on a gold surface via an intermediate layer of polycations. The TIRE measurements allowed the evaluation of thickness changes in the adsorbed molecular layers as a result of chaperone binding to receptor proteins. Hsp70 chaperone isoforms but not Hsp90 were shown to be capable of binding OEP61. Dynamic TIRE measurements were carried out to evaluate the affinity constants of the above reactions and resulted in clear discrimination between specific and nonspecific binding of chaperones as well as differences in binding properties between the highly similar Hsp70 isoforms. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  2. Optical spectroscopic determination of human meniscus composition.

    Science.gov (United States)

    Ala-Myllymäki, Juho; Honkanen, Juuso T J; Töyräs, Juha; Afara, Isaac O

    2016-02-01

    This study investigates the correlation between the composition of human meniscus and its absorption spectrum in the visible (VIS) and near infrared (NIR) spectral range. Meniscus samples (n = 24) were obtained from nonarthritic knees of human cadavers with no history of joint diseases. Specimens (n = 72) were obtained from three distinct sections of the meniscus, namely; anterior, center, posterior. Absorption spectra were acquired from each specimen in the VIS and NIR spectral range (400-1,100 nm). Following spectroscopic probing, the specimens were subjected to biochemical analyses to determine the matrix composition, that is water, hydroxyproline, and uronic acid contents. Multivariate analytical techniques, including principal component analysis (PCA) and partial least squares (PLS) regression, were then used to investigate the correlation between the matrix composition and it spectral response. Our results indicate that the optical absorption of meniscus matrix is related to its composition, and this relationship is optimal in the NIR spectral range (750-1,100 nm). High correlations (R(2) (uronic)  = 86.9%, R(2) (water)  = 83.8%, R(2) (hydroxyproline)  = 81.7%, p meniscus composition, thus suggesting that spectral data in the NIR range can be utilized for estimating the matrix composition of human meniscus. In conclusion, optical spectroscopy, particularly in the NIR spectral range, is a potential method for evaluating the composition of human meniscus. This presents a promising technique for rapid and nondestructive evaluation of meniscus integrity in real-time during arthroscopic surgery. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  3. Optical properties of metals by spectroscopic ellipsometry

    International Nuclear Information System (INIS)

    Arakawa, E.T.; Inagaki, T.; Williams, M.W.

    1979-01-01

    The use of spectroscopic ellipsometry for the accurate determination of the optical properties of liquid and solid metals is discussed and illustrated with previously published data for Li and Na. New data on liquid Sn and Hg from 0.6 to 3.7 eV are presented. Liquid Sn is Drude-like. The optical properties of Hg deviate from the Drude expressions, but simultaneous measurements of reflectance and ellipsometric parameters yield consistent results with no evidence for vectorial surface effects

  4. Emerging optical nanoscopy techniques

    Directory of Open Access Journals (Sweden)

    Montgomery PC

    2015-09-01

    Full Text Available Paul C Montgomery, Audrey Leong-Hoi Laboratoire des Sciences de l'Ingénieur, de l'Informatique et de l'Imagerie (ICube, Unistra-CNRS, Strasbourg, France Abstract: To face the challenges of modern health care, new imaging techniques with subcellular resolution or detection over wide fields are required. Far field optical nanoscopy presents many new solutions, providing high resolution or detection at high speed. We present a new classification scheme to help appreciate the growing number of optical nanoscopy techniques. We underline an important distinction between superresolution techniques that provide improved resolving power and nanodetection techniques for characterizing unresolved nanostructures. Some of the emerging techniques within these two categories are highlighted with applications in biophysics and medicine. Recent techniques employing wider angle imaging by digital holography and scattering lens microscopy allow superresolution to be achieved for subcellular and even in vivo, imaging without labeling. Nanodetection techniques are divided into four subcategories using contrast, phase, deconvolution, and nanomarkers. Contrast enhancement is illustrated by means of a polarized light-based technique and with strobed phase-contrast microscopy to reveal nanostructures. Very high sensitivity phase measurement using interference microscopy is shown to provide nanometric surface roughness measurement or to reveal internal nanometric structures. Finally, the use of nanomarkers is illustrated with stochastic fluorescence microscopy for mapping intracellular structures. We also present some of the future perspectives of optical nanoscopy. Keywords: microscopy, imaging, superresolution, nanodetection, biophysics, medical imaging

  5. Optical constants of graphene measured by spectroscopic ellipsometry

    NARCIS (Netherlands)

    Weber, J.W.; Calado, V.E.; Van de Sanden, M.C.M.

    2010-01-01

    A mechanically exfoliated graphene flake ( ? 150×380??m2) on a silicon wafer with 98 nm silicon dioxide on top was scanned with a spectroscopic ellipsometer with a focused spot ( ? 100×55??m2) at an angle of 55°. The spectroscopic ellipsometric data were analyzed with an optical model in which the

  6. Optical constants of graphene measured by spectroscopic ellipsometry

    NARCIS (Netherlands)

    Weber, J.W.; Calado, V.E.; Sanden, van de M.C.M.

    2010-01-01

    A mechanically exfoliated graphene flake ( ~ 150×380 µm2) on a silicon wafer with 98 nm silicon dioxide on top was scanned with a spectroscopic ellipsometer with a focused spot ( ~ 100×55 µm2) at an angle of 55°. The spectroscopic ellipsometric data were analyzed with an optical model in which the

  7. Spectroscopic analysis technique for arc-welding process control

    Science.gov (United States)

    Mirapeix, Jesús; Cobo, Adolfo; Conde, Olga; Quintela, María Ángeles; López-Higuera, José-Miguel

    2005-09-01

    The spectroscopic analysis of the light emitted by thermal plasmas has found many applications, from chemical analysis to monitoring and control of industrial processes. Particularly, it has been demonstrated that the analysis of the thermal plasma generated during arc or laser welding can supply information about the process and, thus, about the quality of the weld. In some critical applications (e.g. the aerospace sector), an early, real-time detection of defects in the weld seam (oxidation, porosity, lack of penetration, ...) is highly desirable as it can reduce expensive non-destructive testing (NDT). Among others techniques, full spectroscopic analysis of the plasma emission is known to offer rich information about the process itself, but it is also very demanding in terms of real-time implementations. In this paper, we proposed a technique for the analysis of the plasma emission spectrum that is able to detect, in real-time, changes in the process parameters that could lead to the formation of defects in the weld seam. It is based on the estimation of the electronic temperature of the plasma through the analysis of the emission peaks from multiple atomic species. Unlike traditional techniques, which usually involve peak fitting to Voigt functions using the Levenberg-Marquardt recursive method, we employ the LPO (Linear Phase Operator) sub-pixel algorithm to accurately estimate the central wavelength of the peaks (allowing an automatic identification of each atomic species) and cubic-spline interpolation of the noisy data to obtain the intensity and width of the peaks. Experimental tests on TIG-welding using fiber-optic capture of light and a low-cost CCD-based spectrometer, show that some typical defects can be easily detected and identified with this technique, whose typical processing time for multiple peak analysis is less than 20msec. running in a conventional PC.

  8. Band gap tuning in As40Se53Sb07 thin films by 532 nm laser irradiation: An optical investigation by spectroscopic techniques

    Science.gov (United States)

    Pradhan, Prabhudutta; Naik, R.; Das, N.; Panda, A. K.

    2018-01-01

    The chalcogenide thin films belongs to a special category of important materials due to the unique IR transparency and light induced linear and non linear optical properties change. The optical band gap tuning in thermally evaporated As40Se53Sb07 chalcogenide thin film is being probed under the influence of 532 nm laser illumination. The gradual decrease in transmission and red shift of optical absorption edge with illumination at different time scale is recorded by Fourier transmission infrared spectroscopy. The simultaneous increase in refractive index and absorption coefficient of the illuminated film makes the material as useful candidate for optical switching. The dispersion of refractive index is being analyzed by using Wemple-DiDomenico (WDD) single oscillator model and static refractive index (n0) has also been reported. The exponential decrease of optical band gap with time is attributed to the increase in density of localized states and vacancies. The entire mechanism is explained by the microscopic model in which heteropolar bonds are converted to homopolar ones by the absorption of high energy photons investigated by X-ray photoelectron spectra. The amorphous nature of the studied films was revealed from X-ray diffraction and composition of the film was determined from energy dispersive X-ray analysis. The surface morphology was determined from the scanning electron microscopy. The optical change in absorption coefficient, refractive index, band gap by influence in laser irradiation in such materials may be suitable for optical disc(memory) application for optical time division switch.

  9. Characterization of WO3-doped borophosphate glasses by optical, IR and ESR spectroscopic techniques before and after subjecting to gamma irradiation

    International Nuclear Information System (INIS)

    Ouis, M.A.; EI-Batal, H.A.; Azooz, M.A.; Abdelghany, A.M.

    2013-01-01

    Borophosphate glasses containing increasing WO 3 within the doping level (0.16-1.33%) have been prepared and investigated by UV-visible, infrared spectral measurements. These glasses have been exposed to gamma rays with a dose of 8 Mrad for studying the effect of gamma radiation on the combined studied spectra of such glasses. The optical spectrum of undoped borophosphate glass reveals strong UV absorption but with no visible bands. This strong UV absorption is related to the presence of unavoidable trace iron impurities within the chemicals used for the preparation of this borophosphate glass. The WO 3 -doped samples show two additional UV and visible bands at about 380 and 740 nm due to the presence of both W 6+ and W 5+ ions in noticeable content. The calculated induced spectra reveal the appearance of an ultraviolet band at 320 nm and two visible bands centered at 390 and 540 nm which are related to the combined presence of W 6+ and W 5+ ions. The FTIR spectra show vibrational bands due to characteristic constitutional phosphate and borate groups but the phosphate groups are predominant due to the high P 2 O 5 content (50%). The effect of the addition of WO 3 with the dopant level reveals limited changes in the IR spectra. Electron spin resonance (ESR) spectra show specified signals in the high WO 3 content glass but on gamma irradiation the signals are disappeared. This result confirms the decrease of the W 5+ ions by photochemical oxidation to paired W 6+ ions. This result is also observed in optical absorption of WO 3 doped glasses after gamma irradiation through the disappearance of the visible band at 740 nm. (author)

  10. Mechanical contrast in spectroscopic magnetomotive optical coherence elastography

    International Nuclear Information System (INIS)

    Ahmad, Adeel; Huang, Pin-Chieh; Sobh, Nahil A; Pande, Paritosh; Kim, Jongsik; Boppart, Stephen A

    2015-01-01

    The viscoelastic properties of tissues are altered during pathogenesis of numerous diseases and can therefore be a useful indicator of disease status and progression. Several elastography studies have utilized the mechanical frequency response and the resonance frequencies of tissue samples to characterize their mechanical properties. However, using the resonance frequency as a source of mechanical contrast in heterogeneous samples is complicated because it not only depends on the viscoelastic properties but also on the geometry and boundary conditions. In an elastography technique called magnetomotive optical coherence elastography (MM-OCE), the controlled movement of magnetic nanoparticles (MNPs) within the sample is used to obtain the mechanical properties. Previous demonstrations of MM-OCE have typically used point measurements in elastically homogeneous samples assuming a uniform concentration of MNPs. In this study, we evaluate the feasibility of generating MM-OCE elastograms in heterogeneous samples based on a spectroscopic approach which involves measuring the magnetomotive response at different excitation frequencies. Biological tissues and tissue-mimicking phantoms with two elastically distinct regions placed in side-by-side and bilayer configurations were used for the experiments, and finite element method simulations were used to validate the experimental results. (paper)

  11. Spectroscopic technique for measuring atmospheric CO2

    International Nuclear Information System (INIS)

    Stokes, G.M.; Stokes, R.A.

    1979-01-01

    As part of a continuing effort to identify areas in which astronomical techniques and data may be profitably applied to atmospheric problems, both new and archival solar spectra have been collected to prepare for an analysis of their use for studying the changes of the atmospheric CO 2 burden. This analysis has resulted in the initiation of an observing program using the Fourier Transform Spectrometer (FTS) of the McMath Solar Telescope at Kitt Peak National Observatory (KPNO). This program is generating spectra, the quality of which should not only aid the archival CO 2 study but also lead to analyses of other trace gases

  12. Standards development for fiber optic spectroscopic components for adverse environments

    Science.gov (United States)

    Saggese, Steven J.; Greenwell, Roger A.

    1994-09-01

    Optical fiber sensors are finding wider use in all types of applications involving adverse environments, including exposure to radiation. In order to effectively characterize and evaluate the performance of a fiber sensor system for a radiation environment, such as within a nuclear power plant or in a radioactive waste storage/disposal facility, it is beneficial to develop standard test procedures. Science & Engineering Associates (SEA) has developed two such procedures for the American Society for Testing and Materials (ASTM) which address the testing of optical fibers for remote Raman spectroscopic and broadband sensor applications in a steady state radiation environment.

  13. Spectroscopic properties of rare earths in optical materials

    CERN Document Server

    Parisi, Jürgen; Osgood, R; Warlimont, Hans; Liu, Guokui; Jacquier, Bernard

    2005-01-01

    Aimed at researchers and graduate students, this book provides up-to-date information for understanding electronic interactions that impact the optical properties of rare earth ions in solids. Its goal is to establish a connection between fundamental principles and the materials properties of rare-earth activated luminescent and laser optical materials. The theoretical survey and introduction to spectroscopic properties include electronic energy level structure, intensities of optical transitions, ion-phonon interactions, line broadening, and energy transfer and up-conversion. An important aspect of the book lies in its deep and detailed discussions on materials properties and the potential of new applications such as optical storage, information processing, nanophotonics, and molecular probes that have been identified in recent experimental studies. This volume will be a valuable reference book on advanced topics of rare earth spectroscopy and materials science.

  14. Novel spectroscopic techniques with using soft x-ray

    International Nuclear Information System (INIS)

    Gejo, Tatsuo

    2010-01-01

    Recent progress of experimental techniques related to synchrotron radiation makes possible of detail investigation of molecular dynamics after irradiation of soft X-ray. We introduce several novel spectroscopic techniques with using soft X-ray: Symmetry-resolved zero kinetic energy electron spectroscopy, symmetry-resolved metastable photofragment spectroscopy, soft X-ray emission spectroscopy, time-resolved fluorescence spectroscopy, and time-resolved-fluorescence mass-selected-ion coincidence spectroscopy. We also show new techniques performed by other groups at BL27SU in SPring-8. (author)

  15. A COMPARISON OF SPECTROSCOPIC VERSUS IMAGING TECHNIQUES FOR DETECTING CLOSE COMPANIONS TO KEPLER OBJECTS OF INTEREST

    International Nuclear Information System (INIS)

    Teske, Johanna K.; Everett, Mark E.; Hirsch, Lea; Furlan, Elise; Ciardi, David R.; Horch, Elliott P.; Howell, Steve B.; Gonzales, Erica; Crepp, Justin R.

    2015-01-01

    Kepler planet candidates require both spectroscopic and imaging follow-up observations to rule out false positives and detect blended stars. Traditionally, spectroscopy and high-resolution imaging have probed different host star companion parameter spaces, the former detecting tight binaries and the latter detecting wider bound companions as well as chance background stars. In this paper, we examine a sample of 11 Kepler host stars with companions detected by two techniques—near-infrared adaptive optics and/or optical speckle interferometry imaging, and a new spectroscopic deblending method. We compare the companion effective temperatures (T eff ) and flux ratios (F B /F A , where A is the primary and B is the companion) derived from each technique and find no cases where both companion parameters agree within 1σ errors. In 3/11 cases the companion T eff values agree within 1σ errors, and in 2/11 cases the companion F B /F A values agree within 1σ errors. Examining each Kepler system individually considering multiple avenues (isochrone mapping, contrast curves, probability of being bound), we suggest two cases for which the techniques most likely agree in their companion detections (detect the same companion star). Overall, our results support the advantage that the spectroscopic deblending technique has for finding very close-in companions (θ ≲ 0.″02–0.″05) that are not easily detectable with imaging. However, we also specifically show how high-contrast AO and speckle imaging observations detect companions at larger separations (θ ≥ 0.″02–0.″05) that are missed by the spectroscopic technique, provide additional information for characterizing the companion and its potential contamination (e.g., position angle, separation, magnitude differences), and cover a wider range of primary star effective temperatures. The investigation presented here illustrates the utility of combining the two techniques to reveal higher-order multiples in known

  16. IRAS colors of carbon stars - An optical spectroscopic test

    International Nuclear Information System (INIS)

    Cohen, M.; Wainscoat, R.J.; Walker, H.J.; Volk, K.; Schwartz, D.E.

    1989-01-01

    Optical spectra are obtained of 57 photographic counterparts to IRAS sources not previously studied spectroscopically, and expected on the basis of their IRAS colors to be M or C type stars. Confirmed carbon stars are found only in a restricted range of 12-25 index, and constitute a striking vertical sequence in the 12-25-60 micron color-color diagram. This sequence is in accord with evolutionary models for AGB stars that convert M into C stars by dredge-up, and follow loops in the color-color plane. Optically visible and optically invisible carbon stars occupy different color-color locations consistent with their representations of different evolutionary states in the life of relatively low-mass stars. 16 refs

  17. Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits

    Directory of Open Access Journals (Sweden)

    Peeyush Sahay

    2009-10-01

    Full Text Available Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to new heights, moving from laboratory research to commercial reality. Laser spectroscopic detection techniques not only have high-sensitivity and high-selectivity, as equivalently offered by the MS-based techniques, but also have the advantageous features of near real-time response, low instrument costs, and POC function. Of the approximately 35 established breath biomarkers, such as acetone, ammonia, carbon dioxide, ethane, methane, and nitric oxide, 14 species in exhaled human breath have been analyzed by high-sensitivity laser spectroscopic techniques, namely, tunable diode laser absorption spectroscopy (TDLAS, cavity ringdown spectroscopy (CRDS, integrated cavity output spectroscopy (ICOS, cavity enhanced absorption spectroscopy (CEAS, cavity leak-out spectroscopy (CALOS, photoacoustic spectroscopy (PAS, quartz-enhanced photoacoustic spectroscopy (QEPAS, and optical frequency comb cavity-enhanced absorption spectroscopy (OFC-CEAS. Spectral fingerprints of the measured biomarkers span from the UV to the mid-IR spectral regions and the detection limits achieved by the laser techniques range from parts per million to parts per billion levels. Sensors using the laser spectroscopic techniques for a few breath biomarkers, e.g., carbon dioxide, nitric oxide, etc. are commercially available. This review presents an update on the latest developments in laser-based breath analysis.

  18. Optical spectroscopic characteristics of lactate and mitochondrion as new biomarkers in cancer diagnosis: understanding Warburg effect

    Science.gov (United States)

    Liu, C.-H.; Ni, X. H.; Pu, Yang; Yang, Y. L.; Zhou, F.; Zuzolo, R.; Wang, W. B.; Masilamani, V.; Rizwan, A.; Alfano, R. R.

    2012-01-01

    Cancer cells display high rates of glycolysis even under normoxia and mostly under hypoxia. Warburg proposed this effect of altered metabolism in cells more than 80 years ago. It is considered as a hallmark of cancer. Optical spectroscopy can be used to explore this effect. Pathophysiological studies indicate that mitochondria of cancer cells are enlarged and increased in number. Warburg observed that cancer cells tend to convert most glucose to lactate regardless of the presence of oxygen. Previous observations show increased lactate in breast cancer lines. The focus of this study is to investigate the relative content changes of lactate and mitochondria in human cancerous and normal breast tissue samples using optical spectroscopic techniques. The optical spectra were obtained from 30 cancerous and 25 normal breast tissue samples and five model components (Tryptophan, fat, collagen, lactate and mitochondrion) using fluorescence, Stokes shift and Raman spectroscopy. The basic biochemical component analysis model (BBCA) and a set of algorithm were used to analyze the spectra. Our analyses of fluorescence spectra showed a 14 percent increase in lactate content and 2.5 times increase in mitochondria number in cancerous breast tissue as compared with normal tissue. Our findings indicate that optical spectroscopic techniques may be used to understand Warburg effect. Lactate and mitochondrion content changes in tumors examined using optical spectroscopy may be used as a prognostic molecular marker in clinic applications.

  19. Towards optical spectroscopic anatomical mapping (OSAM) for lesion validation in cardiac tissue (Conference Presentation)

    Science.gov (United States)

    Singh-Moon, Rajinder P.; Zaryab, Mohammad; Hendon, Christine P.

    2017-02-01

    Electroanatomical mapping (EAM) is an invaluable tool for guiding cardiac radiofrequency ablation (RFA) therapy. The principle roles of EAM is the identification of candidate ablation sites by detecting regions of abnormal electrogram activity and lesion validation subsequent to RF energy delivery. However, incomplete lesions may present interim electrical inactivity similar to effective treatment in the acute setting, despite efforts to reveal them with pacing or drugs, such as adenosine. Studies report that the misidentification and recovery of such lesions is a leading cause of arrhythmia recurrence and repeat procedures. In previous work, we demonstrated spectroscopic characterization of cardiac tissues using a fiber optic-integrated RF ablation catheter. In this work, we introduce OSAM (optical spectroscopic anatomical mapping), the application of this spectroscopic technique to obtain 2-dimensional biodistribution maps. We demonstrate its diagnostic potential as an auxiliary method for lesion validation in treated swine preparations. Endocardial lesion sets were created on fresh swine cardiac samples using a commercial RFA system. An optically-integrated catheter console fabricated in-house was used for measurement of tissue optical spectra between 600-1000nm. Three dimensional, Spatio-spectral datasets were generated by raster scanning of the optical catheter across the treated sample surface in the presence of whole blood. Tissue optical parameters were recovered at each spatial position using an inverse Monte Carlo method. OSAM biodistribution maps showed stark correspondence with gross examination of tetrazolium chloride stained tissue specimens. Specifically, we demonstrate the ability of OSAM to readily distinguish between shallow and deeper lesions, a limitation faced by current EAM techniques. These results showcase the OSAMs potential for lesion validation strategies for the treatment of cardiac arrhythmias.

  20. Spectroscopic Doppler analysis for visible-light optical coherence tomography

    Science.gov (United States)

    Shu, Xiao; Liu, Wenzhong; Duan, Lian; Zhang, Hao F.

    2017-12-01

    Retinal oxygen metabolic rate can be effectively measured by visible-light optical coherence tomography (vis-OCT), which simultaneously quantifies oxygen saturation and blood flow rate in retinal vessels through spectroscopic analysis and Doppler measurement, respectively. Doppler OCT relates phase variation between sequential A-lines to the axial flow velocity of the scattering medium. The detectable phase shift is between -π and π due to its periodicity, which limits the maximum measurable unambiguous velocity without phase unwrapping. Using shorter wavelengths, vis-OCT is more vulnerable to phase ambiguity since flow induced phase variation is linearly related to the center wavenumber of the probing light. We eliminated the need for phase unwrapping using spectroscopic Doppler analysis. We split the whole vis-OCT spectrum into a series of narrow subbands and reconstructed vis-OCT images to extract corresponding Doppler phase shifts in all the subbands. Then, we quantified flow velocity by analyzing subband-dependent phase shift using linear regression. In the phantom experiment, we showed that spectroscopic Doppler analysis extended the measurable absolute phase shift range without conducting phase unwrapping. We also tested this method to quantify retinal blood flow in rodents in vivo.

  1. Non-invasive spectroscopic techniques in the diagnosis of non-melanoma skin cancer

    Science.gov (United States)

    Drakaki, E.; Sianoudis, IA; Zois, EN; Makropoulou, M.; Serafetinides, AA; Dessinioti, C.; Stefanaki, E.; Stratigos, AJ; Antoniou, C.; Katsambas, A.; Christofidou, E.

    2017-11-01

    The number of non-melanoma skin cancers is increasing worldwide and has become an important health and economic issue. Early detection and treatment of skin cancer can significantly improve patient outcome. Therefore there is an increase in the demand for proper management and effective non-invasive diagnostic modalities in order to avoid relapses or unnecessary treatments. Although the gold standard of diagnosis for non-melanoma skin cancers is biopsy followed by histopathology evaluation, optical non-invasive diagnostic tools have obtained increased attention. Emerging non-invasive or minimal invasive techniques with possible application in the diagnosis of non-melanoma skin cancers include high-definition optical coherence tomography, fluorescence spectroscopy, oblique incidence diffuse reflectance spectrometry among others spectroscopic techniques. Our findings establish how those spectrometric techniques can be used to more rapidly and easily diagnose skin cancer in an accurate and automated manner in the clinic.

  2. Spectroscopic and electrochemical characterization of nanostructured optically transparent carbon electrodes.

    Science.gov (United States)

    Benavidez, Tomás E; Garcia, Carlos D

    2013-07-01

    The present paper describes the results related to the optical and electrochemical characterization of thin carbon films fabricated by spin coating and pyrolysis of AZ P4330-RS photoresist. The goal of this paper is to provide comprehensive information allowing for the rational selection of the conditions to fabricate optically transparent carbon electrodes (OTCE) with specific electrooptical properties. According to our results, these electrodes could be appropriate choices as electrochemical transducers to monitor electrophoretic separations. At the core of this manuscript is the development and critical evaluation of a new optical model to calculate the thickness of the OTCE by variable angle spectroscopic ellipsometry. Such data were complemented with topography and roughness (obtained by atomic force microscopy), electrochemical properties (obtained by cyclic voltammetry), electrical properties (obtained by electrochemical impedance spectroscopy), and structural composition (obtained by Raman spectroscopy). Although the described OTCE were used as substrates to investigate the effect of electrode potential on the real-time adsorption of proteins by ellipsometry, these results could enable the development of other biosensors that can be then integrated into various CE platforms. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Optical and spectroscopic study of erbium doped calcium borotellurite glasses

    Science.gov (United States)

    Gomes, J. F.; Lima, A. M. O.; Sandrini, M.; Medina, A. N.; Steimacher, A.; Pedrochi, F.; Barboza, M. J.

    2017-04-01

    In this study, 10CaF2 - (29.9-0.4x)CaO - (60-0.6x)B2O3 - xTeO2 - 0,1Er2O3 (x = 10, 16, 22, 30 and 50 mol %) glasses were synthesized, and their optical and spectroscopic properties were investigated. X-ray diffraction, density, glass transition temperature (Tg), crystallization temperature (Tx), refraction index, luminescence, radiative lifetime and optical absorption measurements were carried out. Molar volume (Vm), thermal stability (Tx-Tg), electronic polarizability (αm), optical bang gap energy (Eg) and Judd-Ofelt (JO) parameters Ωt (2,4,6) were also calculated. The results are discussed in terms of tellurium oxide content. The increase of TeO2 in the glasses composition increases density, refractive index and electronic polarizability. The optical band gap energy decreases varying from 3.37 to 2.71 eV for the glasses with 10 and 50 mol% of TeO2, respectively. The optical absorption coefficient spectra show characteristic bands of Er3+ ions. Furthermore, these spectra in NIR region show a decrease of hydroxyl groups as a function of TeO2 addition. Luminescence intensity and radiative lifetimes at 1530 nm show an increasing with the TeO2 content. The JO parameters of Er:CaBTeX glasses follow the trend Ω2 > Ω4 > Ω6 and the quality factor values (Ω4/Ω6) were between 1.37 and 3.07. By comparing the measured lifetime with the calculated radiative decay time, quantum efficiency was calculated. The luminescence emission intensity at 1530 nm decreases with the increase of temperature. The lifetime values show a slight trend to decrease with the temperature increase, from 300 to 420 K, for all the samples.

  4. Temperature analysis of laser ignited metalized material using spectroscopic technique

    Science.gov (United States)

    Bassi, Ishaan; Sharma, Pallavi; Daipuriya, Ritu; Singh, Manpreet

    2018-05-01

    The temperature measurement of the laser ignited aluminized Nano energetic mixture using spectroscopy has a great scope in in analysing the material characteristic and combustion analysis. The spectroscopic analysis helps to do in depth study of combustion of materials which is difficult to do using standard pyrometric methods. Laser ignition was used because it consumes less energy as compared to electric ignition but ignited material dissipate the same energy as dissipated by electric ignition and also with the same impact. Here, the presented research is primarily focused on the temperature analysis of energetic material which comprises of explosive material mixed with nano-material and is ignited with the help of laser. Spectroscopy technique is used here to estimate the temperature during the ignition process. The Nano energetic mixture used in the research does not comprise of any material that is sensitive to high impact.

  5. Quantification of UV-Visible and Laser Spectroscopic Techniques for Materials Accountability and Process Control

    International Nuclear Information System (INIS)

    Czerwinski, Kenneth; Weck, Phil

    2013-01-01

    Ultraviolet-visible spectroscopy (UV-Visible) and time-resolved laser fluorescence spectroscopy (TRLFS) optical techniques can permit on-line analysis of actinide elements in a solvent extraction process in real time. These techniques have been used for measuring actinide speciation and concentration under laboratory conditions and are easily adaptable to multiple sampling geometries, such as dip probes, fiber-optic sample cells, and flow-through cell geometries. To fully exploit these techniques, researchers must determine the fundamental speciation of target actinides and the resulting influence on spectroscopic properties. Detection limits, process conditions, and speciation of key actinide components can be established and utilized in a range of areas, particularly those related to materials accountability and process control. Through this project, researchers will develop tools and spectroscopic techniques to evaluate solution extraction conditions and concentrations of U, Pu, and Cm in extraction processes, addressing areas of process control and materials accountability. The team will evaluate UV- Visible and TRLFS for use in solvent extraction-based separations. Ongoing research is examining efficacy of UV-Visible spectroscopy to evaluate uranium and plutonium speciation under conditions found in the UREX process and using TRLFS to evaluate Cm speciation and concentration in the TALSPEAK process. A uranyl and plutonium nitrate UV-Visible spectroscopy study met with success, which supports the utility and continued exploration of spectroscopic methods for evaluation of actinide concentrations and solution conditions for other aspects of the UREX+ solvent extraction scheme. This project will examine U and Pu absorbance in TRUEX and TALSPEAK, perform detailed examination of Cm in TRUEX and TALSPEAK, study U laser fluorescence, and apply project data to contactors. The team will also determine peak ratios as a function of solution concentrations for the UV

  6. A COMPARISON OF SPECTROSCOPIC VERSUS IMAGING TECHNIQUES FOR DETECTING CLOSE COMPANIONS TO KEPLER OBJECTS OF INTEREST

    Energy Technology Data Exchange (ETDEWEB)

    Teske, Johanna K. [Carnegie DTM, 5241 Broad Branch Road, NW, Washington, DC 20015 (United States); Everett, Mark E. [National Optical Astronomy Observatory, 950 N. Cherry Ave., Tucson, AZ 85719 (United States); Hirsch, Lea [Astronomy Department, University of California at Berkeley, Berkeley, CA 94720 (United States); Furlan, Elise; Ciardi, David R. [NASA Exoplanet Science Institute, California Institute of Technology, 770 South Wilson Ave., Pasadena, CA 91125 (United States); Horch, Elliott P. [Department of Physics, Southern Connecticut State University, 501 Crescent Street, New Haven, CT 06515 (United States); Howell, Steve B. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Gonzales, Erica; Crepp, Justin R., E-mail: jteske@carnegiescience.edu [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556 (United States)

    2015-11-15

    Kepler planet candidates require both spectroscopic and imaging follow-up observations to rule out false positives and detect blended stars. Traditionally, spectroscopy and high-resolution imaging have probed different host star companion parameter spaces, the former detecting tight binaries and the latter detecting wider bound companions as well as chance background stars. In this paper, we examine a sample of 11 Kepler host stars with companions detected by two techniques—near-infrared adaptive optics and/or optical speckle interferometry imaging, and a new spectroscopic deblending method. We compare the companion effective temperatures (T{sub eff}) and flux ratios (F{sub B}/F{sub A}, where A is the primary and B is the companion) derived from each technique and find no cases where both companion parameters agree within 1σ errors. In 3/11 cases the companion T{sub eff} values agree within 1σ errors, and in 2/11 cases the companion F{sub B}/F{sub A} values agree within 1σ errors. Examining each Kepler system individually considering multiple avenues (isochrone mapping, contrast curves, probability of being bound), we suggest two cases for which the techniques most likely agree in their companion detections (detect the same companion star). Overall, our results support the advantage that the spectroscopic deblending technique has for finding very close-in companions (θ ≲ 0.″02–0.″05) that are not easily detectable with imaging. However, we also specifically show how high-contrast AO and speckle imaging observations detect companions at larger separations (θ ≥ 0.″02–0.″05) that are missed by the spectroscopic technique, provide additional information for characterizing the companion and its potential contamination (e.g., position angle, separation, magnitude differences), and cover a wider range of primary star effective temperatures. The investigation presented here illustrates the utility of combining the two techniques to reveal higher

  7. Glucose Oxidase Adsorption on Sequential Adsorbed Polyelectrolyte Films Studied by Spectroscopic Techniques

    Science.gov (United States)

    Tristán, Ferdinando; Solís, Araceli; Palestino, Gabriela; Gergely, Csilla; Cuisinier, Frédéric; Pérez, Elías

    2005-04-01

    The adsorption of Glucose Oxidase (GOX) on layers of poly(allylamine hydrochloride) (PAH) and poly(acrylic acid) (PAA) deposited on Sequentially Adsorbed Polyelectrolyte Films (SAPFs) were studied by three different spectroscopic techniques. These techniques are: Optical Wave Light Spectroscopy (OWLS) to measure surface density; Fluorescence Resonance Energy Transfer (FRET) to verify the adsorption of GOX on the surface; and Fourier Transform Infrared Spectroscopy in Attenuated Total Reflection mode (FTIR-HATR) to inspect local structure of polyelectrolytes and GOX. Two positive and two negative polyelectrolytes are used: Cationic poly(ethyleneimine) (PEI) and poly(allylamine hydrochloride) (PAH) and anionic poly(sodium 4-styrene sulfonate) (PSS) and poly(acrylic acid) (PAA). These spectroscopic techniques do not require any labeling for GOX or SAPFs, specifically GOX and PSS are naturally fluorescent and are used as a couple donor-acceptor for the FRET technique. The SAPFs are formed by a (PEI)-(PSS/PAH)2 film followed by (PAA/PAH)n bilayers. GOX is finally deposited on top of SAPFs at different values of n (n=1..5). Our results show that GOX is adsorbed on positive ended SAPFs forming a monolayer. Contrary, GOX adsorption is not observed on negative ended film polyelectrolyte. GOX stability was tested adding a positive and a negative polyelectrolyte after GOX adsorption. Protein is partially removed by PAH and PAA, with lesser force by PAA.

  8. The optical characterization of organometallic complex thin films by spectroscopic ellipsometry and photovoltaic diode application

    Energy Technology Data Exchange (ETDEWEB)

    Özaydın, C. [Batman University, Engineering Faculty, Department of Computer Eng., Batman (Turkey); Güllü, Ö., E-mail: omergullu@gmail.com [Batman University, Science and Art Faculty, Department of Physics, Batman (Turkey); Pakma, O. [Batman University, Science and Art Faculty, Department of Physics, Batman (Turkey); Ilhan, S. [Siirt University, Science and Art Faculty, Department of Chemistry, Siirt (Turkey); Akkılıç, K. [Dicle University, Education Faculty, Department of Physics Education, Diyarbakır (Turkey)

    2016-05-15

    Highlights: • Optical properties and thickness of the A novel organometallic complex (OMC) film were investigated by spectroscopic ellipsometry (SE). • Au/OMC/n-Si metal/interlayer/semiconductor (MIS) diode has been fabricated • This paper presents the I–V analysis of Au/OMC/n-Si MIS diode. • Current–voltage and photovoltaic properties of the diode were investigated. - Abstract: In this work, organometallic complex (OMC) films have been deposited onto glass or silicon substrates by spin coating technique and their photovoltaic application potential has been investigated. Optical properties and thickness of the film have been investigated by spectroscopic ellipsometry (SE). Also, transmittance spectrum has been taken by UV/vis spectrophotometer. The optical method has been used to determine the band gap value of the films. Also, Au/OMC/n-Si metal/interlayer/semiconductor (MIS) diode has been fabricated. Current–voltage and photovoltaic properties of the structure were investigated. The ideality factor (n) and barrier height (Φ{sub b}) values of the diode were found to be 2.89 and 0.79 eV, respectively. The device shows photovoltaic behavior with a maximum open-circuit voltage of 396 mV and a short circuit current of 33.8 μA under 300 W light.

  9. The optical characterization of organometallic complex thin films by spectroscopic ellipsometry and photovoltaic diode application

    International Nuclear Information System (INIS)

    Özaydın, C.; Güllü, Ö.; Pakma, O.; Ilhan, S.; Akkılıç, K.

    2016-01-01

    Highlights: • Optical properties and thickness of the A novel organometallic complex (OMC) film were investigated by spectroscopic ellipsometry (SE). • Au/OMC/n-Si metal/interlayer/semiconductor (MIS) diode has been fabricated • This paper presents the I–V analysis of Au/OMC/n-Si MIS diode. • Current–voltage and photovoltaic properties of the diode were investigated. - Abstract: In this work, organometallic complex (OMC) films have been deposited onto glass or silicon substrates by spin coating technique and their photovoltaic application potential has been investigated. Optical properties and thickness of the film have been investigated by spectroscopic ellipsometry (SE). Also, transmittance spectrum has been taken by UV/vis spectrophotometer. The optical method has been used to determine the band gap value of the films. Also, Au/OMC/n-Si metal/interlayer/semiconductor (MIS) diode has been fabricated. Current–voltage and photovoltaic properties of the structure were investigated. The ideality factor (n) and barrier height (Φ_b) values of the diode were found to be 2.89 and 0.79 eV, respectively. The device shows photovoltaic behavior with a maximum open-circuit voltage of 396 mV and a short circuit current of 33.8 μA under 300 W light.

  10. Optical and spectroscopic investigation on Calcium Borotellurite glass system

    Science.gov (United States)

    Paz, E. C.; Lodi, T. A.; Gomes, B. R. A.; Melo, G. H. A.; Pedrochi, F.; Steimacher, A.

    2016-05-01

    In this work, the glass formation in Calcium Borotellurite (CBTx) system and their optical properties were studied. Six glass samples were prepared by melt-quenching technique and the samples obtained are transparent, lightly yellowish, without any visible crystallites. The results showed that TeO2 addition increases the density, the electronic polarizability and, consequently, the refractive index. The increase of electronic polarizability and optical basicity suggest that TeO2 addition increases the non-bridging oxygen (NBO) concentration. The increase of TeO2 shifts the band edge to longer wavelength owing to increase in non-bridging oxygen ions, resulting in a linear decrease of optical energy gap. The addition of TeO2 increases the temperature coefficient of the optical path length (dS/dT) in room temperature, which are comparable to phosphate and lower than Low Silica Calcium Alumino Silicate (LSCAS) glasses. The values of dS/dT present an increase as a function of temperature for all the samples measured. The results suggest that CBTx is a good candidate for rare-earth doping and several optical applications.

  11. Spectroscopic Classifications of Optical Transients with the Lick Shane 3-m telescope

    Science.gov (United States)

    Dimitriadis, G.; Foley, R. J.

    2018-05-01

    We report the following classifications of optical transients from spectroscopic observations with the Kast spectrograph on the Shane 3-m telescope. Targets were supplied by ATLAS, ASAS-SN, and the KEGS K2 SN search.

  12. In vivo, noninvasive functional measurements of bone sarcoma using diffuse optical spectroscopic imaging

    Science.gov (United States)

    Peterson, Hannah M.; Hoang, Bang H.; Geller, David; Yang, Rui; Gorlick, Richard; Berger, Jeremy; Tingling, Janet; Roth, Michael; Gill, Jonathon; Roblyer, Darren

    2017-12-01

    Diffuse optical spectroscopic imaging (DOSI) is an emerging near-infrared imaging technique that noninvasively measures quantitative functional information in thick tissue. This study aimed to assess the feasibility of using DOSI to measure optical contrast from bone sarcomas. These tumors are rare and pose technical and practical challenges for DOSI measurements due to the varied anatomic locations and tissue depths of presentation. Six subjects were enrolled in the study. One subject was unable to be measured due to tissue contact sensitivity. For the five remaining subjects, the signal-to-noise ratio, imaging depth, optical properties, and quantitative tissue concentrations of oxyhemoglobin, deoxyhemoglobin, water, and lipids from tumor and contralateral normal tissues were assessed. Statistical differences between tumor and contralateral normal tissue were found in chromophore concentrations and optical properties for four subjects. Low signal-to-noise was encountered during several subject's measurements, suggesting increased detector sensitivity will help to optimize DOSI for this patient population going forward. This study demonstrates that DOSI is capable of measuring optical properties and obtaining functional information in bone sarcomas. In the future, DOSI may provide a means to stratify treatment groups and monitor chemotherapy response for this disease.

  13. Raman spectroscopic studies of optically trapped red blood cells

    International Nuclear Information System (INIS)

    Dasgupta, R.; Gupta, P.K.

    2010-01-01

    Raman spectroscopic studies were performed on optically trapped red blood cells (RBCs) collected from healthy volunteers and patients suffering from malaria (Plasmodium vivax infection) using near infrared (785 nm) laser source. The results show significant alteration in the spectra averaged over ∼ 50 non-parasitized RBCs per sample. As compared to RBCs from healthy donors, in cells collected from malaria patients, a significant decrease in the intensity of the low spin (oxygenated-haemoglobin) marker Raman band at 1223 cm -1 (υ 13 or υ 42 ) along with a concomitant increase in the high spin (deoxygenated-haemoglobin) marker bands at 1210 cm -1 (υ 5 + υ 18 ) and 1546 cm -1 (υ 11 ) was observed. The changes primarily suggest a reduced haemoglobin-oxygen affinity for the non-parasitized red cells in malaria patients. The possible causes include up regulation of intra-erythrocytic 2,3-diphosphoglycerate and/or ineffective erythropoiesis resulted from the disease. During the above study we also observed that significant photo-damage may results to the intracellular haemoglobin (Hb) if higher laser power is used. For a laser power above ∼ 5 mW the observed increase in intensity of the Raman bands at 975 cm -1 (υ 46 ), 1244 cm -1 (υ 42 ) and 1366 cm -1 (υ 4 ) with increasing exposure time suggests photo-denaturation of Hb and the concomitant decrease in intensity of the Raman band at 1544 cm -1 (υ 11 ) suggests photo induced methaemoglobin formation. The photo damage of intracellular haemoglobin by the above processes was also observed to result in intracellular heme aggregation. (author)

  14. Optical spectroscopic analysis for the discrimination of extra-virgin olive-oil (Conference Presentation)

    Science.gov (United States)

    McReynolds, Naomi; Auñón Garcia, Juan M.; Guengerich, Zoe; Smith, Terry K.; Dholakia, Kishan

    2017-02-01

    We present an optical spectroscopic technique, making use of both Raman signals and fluorescence spectroscopy, for the identification of five brands of commercially available extra-virgin olive-oil (EVOO). We demonstrate our technique on both a `bulk-optics' free-space system and a compact device. Using the compact device, which is capable of recording both Raman and fluorescence signals, we achieved an average sensitivity and specificity of 98.4% and 99.6% for discrimination, respectively. Our approach demonstrates that both Raman and fluorescence spectroscopy can be used for portable discrimination of EVOOs which obviates the need to use centralised laboratories and opens up the prospect of in-field testing. This technique may enable detection of EVOO that has undergone counterfeiting or adulteration. One of the main challenges facing Raman spectroscopy for use in quality control of EVOOs is that the oxidation of EVOO, which naturally occurs due to aging, causes shifts in Raman spectra with time, which implies regular retraining would be necessary. We present a potential method of analysis to minimize the effect that aging has on discrimination efficiency; we show that by discarding the first principal component, which contains information on the variations due to oxidation, we can improve discrimination efficiency thus improving the robustness of our technique.

  15. Studies on selected polymeric materials using the photoacoustic spectroscopic technique

    International Nuclear Information System (INIS)

    Singh, Hukum

    2011-01-01

    Polymethylmethacrylate—graft—polybisphenol—A-carbonate (PMMA-G-PC) with 50% grafting is synthesized. The graft co-polymerization of methylmethacrylate (0.036 mol · lit −1 ) onto polybisphenol—A-carbonate (0.5 g) in the presence of a redox couple formed from potassium persulphate (40 mol · lit −1 ) and thio-urea (30 mmol · lit −1 ) in aqueous nitric acid (0.18 M, 100 ml) in air at (45±2) °C for 3.0 h. Condensation of (PMMA-G-PC) with N- [p-(carboxyl phenyl amino acetic acid)] hydrazide (PCPH) affords polybisphenol-A-carbonate-graft-polymethylmethacrylate hydrazide (PCGH). The photoacoustic (PA) spectra of (PCGH) are recorded in a wavelength range from 200 nm to 800 nm at a modulation frequency of 22 Hz, and compared with those of pure polybisphenol-A-carbonate (PC), (PMMA-G-PC) and (PCPH). In the present work, a non-destructive and non-contact analytical method, namely the photoacoustic technique, is successfully implemented for optical and thermal characterization of selected polymeric materials. The indigenous PA spectrometer used in the present study consists of a 300-W xenon arc lamp, a lock-in amplifier, a chopper, a (1/8)-m monochromator controlled by computer and a home-made PA cell. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  16. Speciation, in the nuclear fuel cycle by spectroscopic techniques

    International Nuclear Information System (INIS)

    Colette, S.; Plancque, G.; Allain, F.; Lamouroux, C.; Steiner, V.; Amekraz, B.; Moulin, C.

    2000-01-01

    New analytical techniques allowing to perform speciation in the framework of the nuclear fuel cycle are more and more needed. They have to be selective (since matrix encountered are very complex), sensitive (in order to work at representative concentration and below solubility limit), as well as non intrusive (in order to keep the image of the real solution). Among them, laser-based analytical techniques present these advantages together with the possibility to perform remote measurements via fiber optics. Hence, Time-Resolved Laser-Induced Fluorescence (TRLIF) has been used for actinides/lanthanides interaction and speciation studies in inorganic and organic matrices from the reprocessing to waste storage. Moreover, new ion detection methods such as Electro-Spray - Mass Spectrometry (ES-MS) seems promising for speciation studies. Hence, it is the first time that it is possible to directly couple a liquid at atmospheric pressure to a mass detection working at reduced pressure with a soft mode of ionisation that should allow to give informations on chemical species present. Principle, advantages and limitations as well as results obtained with the use of TRLIF and ES-MS on different systems of interest including actinides, lanthanides, fission products in interaction with simple organic molecules to very complex structure will be presented and discussed. (authors)

  17. Speciation, in the nuclear fuel cycle by spectroscopic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Colette, S.; Plancque, G.; Allain, F.; Lamouroux, C.; Steiner, V.; Amekraz, B.; Moulin, C. [CEA/Saclay, Dept, des Procedes d' Enrichissement (DPE), 91 - Gif-sur-Yvette (France)

    2000-07-01

    New analytical techniques allowing to perform speciation in the framework of the nuclear fuel cycle are more and more needed. They have to be selective (since matrix encountered are very complex), sensitive (in order to work at representative concentration and below solubility limit), as well as non intrusive (in order to keep the image of the real solution). Among them, laser-based analytical techniques present these advantages together with the possibility to perform remote measurements via fiber optics. Hence, Time-Resolved Laser-Induced Fluorescence (TRLIF) has been used for actinides/lanthanides interaction and speciation studies in inorganic and organic matrices from the reprocessing to waste storage. Moreover, new ion detection methods such as Electro-Spray - Mass Spectrometry (ES-MS) seems promising for speciation studies. Hence, it is the first time that it is possible to directly couple a liquid at atmospheric pressure to a mass detection working at reduced pressure with a soft mode of ionisation that should allow to give informations on chemical species present. Principle, advantages and limitations as well as results obtained with the use of TRLIF and ES-MS on different systems of interest including actinides, lanthanides, fission products in interaction with simple organic molecules to very complex structure will be presented and discussed. (authors)

  18. Development and Quantification of UV-Visible and Laser Spectroscopic Techniques for Materials Accountability and Process Control

    International Nuclear Information System (INIS)

    Czerwinski, Ken; Weck, Phil; Poineau, Frederic

    2010-01-01

    Ultraviolet-Visible Spectroscopy (UV-Visible) and Time Resolved Laser Fluorescence Spectroscopy (TRLFS) optical techniques can permit on-line, real-time analysis of the actinide elements in a solvent extraction process. UV-Visible and TRLFS techniques have been used for measuring the speciation and concentration of the actinides under laboratory conditions. These methods are easily adaptable to multiple sampling geometries, such as dip probes, fiber-optic sample cells, and flow-through cell geometries. To fully exploit these techniques for GNEP applications, the fundamental speciation of the target actinides and the resulting influence on 3 spectroscopic properties must be determined. Through this effort detection limits, process conditions, and speciation of key actinide components can be establish and utilized in a range of areas of interest to GNEP, especially in areas related to materials accountability and process control.

  19. Optical metrology techniques for dimensional stability measurements

    NARCIS (Netherlands)

    Ellis, Jonathan David

    2010-01-01

    This thesis work is optical metrology techniques to determine material stability. In addition to displacement interferometry, topics such as periodic nonlinearity, Fabry-Perot interferometry, refractometry, and laser stabilization are covered.

  20. Optical rangefinding applications using communications modulation technique

    Science.gov (United States)

    Caplan, William D.; Morcom, Christopher John

    2010-10-01

    A novel range detection technique combines optical pulse modulation patterns with signal cross-correlation to produce an accurate range estimate from low power signals. The cross-correlation peak is analyzed by a post-processing algorithm such that the phase delay is proportional to the range to target. This technique produces a stable range estimate from noisy signals. The advantage is higher accuracy obtained with relatively low optical power transmitted. The technique is useful for low cost, low power and low mass sensors suitable for tactical use. The signal coding technique allows applications including IFF and battlefield identification systems.

  1. Optical coherence techniques for plasma doppler spectroscopy

    International Nuclear Information System (INIS)

    Howard, J.; Michael, C.; Glass, F.; Cheetham, A.D.

    2000-01-01

    A new electro-optically Modulated Optical Solid-State (MOSS) interferometer has been constructed for measurement of the low order spectral moments of line emission from optically thin radiant media. The instrument, which is based on the principle of the Fourier transform spectrometer, has high etendue and is rugged, compact and inexpensive. By employing electro-optical path-length modulation techniques, the spectral information is transferred to the temporal frequency domain and can be obtained using a single photodetector. Specifically, the zeroth moment (brightness) is given by the average signal level, the first moment (shift) by the modulation phase and the second moment (line width) by the modulation amplitude. (author)

  2. Fiber optic spectroscopic digital imaging sensor and method for flame properties monitoring

    Science.gov (United States)

    Zelepouga, Serguei A [Hoffman Estates, IL; Rue, David M [Chicago, IL; Saveliev, Alexei V [Chicago, IL

    2011-03-15

    A system for real-time monitoring of flame properties in combustors and gasifiers which includes an imaging fiber optic bundle having a light receiving end and a light output end and a spectroscopic imaging system operably connected with the light output end of the imaging fiber optic bundle. Focusing of the light received by the light receiving end of the imaging fiber optic bundle by a wall disposed between the light receiving end of the fiber optic bundle and a light source, which wall forms a pinhole opening aligned with the light receiving end.

  3. Quantitative comparison of analysis methods for spectroscopic optical coherence tomography: reply to comment

    NARCIS (Netherlands)

    Bosschaart, Nienke; van Leeuwen, Ton; Aalders, Maurice C.G.; Faber, Dirk

    2014-01-01

    We reply to the comment by Kraszewski et al on “Quantitative comparison of analysis methods for spectroscopic optical coherence tomography.” We present additional simulations evaluating the proposed window function. We conclude that our simulations show good qualitative agreement with the results of

  4. Performance Monitoring Techniques Supporting Cognitive Optical Networking

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Borkowski, Robert; Zibar, Darko

    2013-01-01

    High degree of heterogeneity of future optical networks, such as services with different quality-of-transmission requirements, modulation formats and switching techniques, will pose a challenge for the control and optimization of different parameters. Incorporation of cognitive techniques can help...... to solve this issue by realizing a network that can observe, act, learn and optimize its performance, taking into account end-to-end goals. In this letter we present the approach of cognition applied to heterogeneous optical networks developed in the framework of the EU project CHRON: Cognitive...... Heterogeneous Reconfigurable Optical Network. We focus on the approaches developed in the project for optical performance monitoring, which enable the feedback from the physical layer to the cognitive decision system by providing accurate description of the performance of the established lightpaths....

  5. A STUDY ON OPTICAL CHARACTER RECOGNITION TECHNIQUES

    OpenAIRE

    Narendra Sahu; Manoj Sonkusare

    2018-01-01

    Optical Character Recognition (OCR) is the process which enables a system to without human intervention identifies the scripts or alphabets written into the users’ verbal communication. Optical Character identification has grown to be individual of the mainly flourishing applications of knowledge in the field of pattern detection and artificial intelligence. In our survey we study on the various OCR techniques. In this paper we resolve and examine the hypothetical and numerical models of Opti...

  6. Compact Optical Technique for Streak Camera Calibration

    International Nuclear Information System (INIS)

    Curt Allen; Terence Davies; Frans Janson; Ronald Justin; Bruce Marshall; Oliver Sweningsen; Perry Bell; Roger Griffith; Karla Hagans; Richard Lerche

    2004-01-01

    The National Ignition Facility is under construction at the Lawrence Livermore National Laboratory for the U.S. Department of Energy Stockpile Stewardship Program. Optical streak cameras are an integral part of the experimental diagnostics instrumentation. To accurately reduce data from the streak cameras a temporal calibration is required. This article describes a technique for generating trains of precisely timed short-duration optical pulses that are suitable for temporal calibrations

  7. Investigation of the optical properties of MoS{sub 2} thin films using spectroscopic ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Chanyoung; O' Brien, Maria; Winters, Sinéad [School of Chemistry, Trinity College Dublin, Dublin 2 (Ireland); Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN), Trinity College Dublin, Dublin 2 (Ireland); McEvoy, Niall [Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN), Trinity College Dublin, Dublin 2 (Ireland); Mirza, Inam; Lunney, James G. [Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN), Trinity College Dublin, Dublin 2 (Ireland); School of Physics, Trinity College Dublin, Dublin 2 (Ireland); Duesberg, Georg S., E-mail: duesberg@tcd.ie [School of Chemistry, Trinity College Dublin, Dublin 2 (Ireland); Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN), Trinity College Dublin, Dublin 2 (Ireland); Advanced Materials and BioEngineering Research (AMBER) Centre, Trinity College Dublin, Dublin 2 (Ireland)

    2014-03-10

    Spectroscopic ellipsometry (SE) characterization of layered transition metal dichalcogenide (TMD) thin films grown by vapor phase sulfurization is reported. By developing an optical dispersion model, the extinction coefficient and refractive index, as well as the thickness of molybdenum disulfide (MoS{sub 2}) films, were extracted. In addition, the optical band gap was obtained from SE and showed a clear dependence on the MoS{sub 2} film thickness, with thinner films having a larger band gap energy. These results are consistent with theory and observations made on MoS{sub 2} flakes prepared by exfoliation, showing the viability of vapor phase derived TMDs for optical applications.

  8. Investigation of the optical properties of MoS2 thin films using spectroscopic ellipsometry

    International Nuclear Information System (INIS)

    Yim, Chanyoung; O'Brien, Maria; Winters, Sinéad; McEvoy, Niall; Mirza, Inam; Lunney, James G.; Duesberg, Georg S.

    2014-01-01

    Spectroscopic ellipsometry (SE) characterization of layered transition metal dichalcogenide (TMD) thin films grown by vapor phase sulfurization is reported. By developing an optical dispersion model, the extinction coefficient and refractive index, as well as the thickness of molybdenum disulfide (MoS 2 ) films, were extracted. In addition, the optical band gap was obtained from SE and showed a clear dependence on the MoS 2 film thickness, with thinner films having a larger band gap energy. These results are consistent with theory and observations made on MoS 2 flakes prepared by exfoliation, showing the viability of vapor phase derived TMDs for optical applications

  9. Spectroscopic ellipsometry investigations of optical anisotropy in obliquely deposited hafnia thin films

    Energy Technology Data Exchange (ETDEWEB)

    Tokas, R. B., E-mail: tokasstar@gmail.com; Jena, Shuvendu; Thakur, S.; Sahoo, N. K. [Atomic & Molecular Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai-85 (India); Haque, S. Maidul; Rao, K. Divakar [Photonics & Nanotechnology Section, Atomic & Molecular Physics Division, Bhabha Atomic Research Centre facility, Visakhapatnam-530012 (India)

    2016-05-23

    In present work, HfO{sub 2} thin films have been deposited at various oblique incidences on Si substrates by electron beam evaporation. These refractory oxide films exhibited anisotropy in refractive index predictably due to special columnar microstructure. Spectroscopic ellipsometry being a powerful tool for optical characterization has been employed to investigate optical anisotropy. It was observed that the film deposited at glancing angle (80°) exhibits the highest optical anisotropy. Further, anisotropy was noticed to decrease with lower values of deposition angles while effective refractive index depicts opposite trend. Variation in refractive index and anisotropy has been explained in light of atomic shadowing during growth of thin films at oblique angles.

  10. Optical spectroscopic studies of L-alanyl-L-alanine

    Czech Academy of Sciences Publication Activity Database

    Šebek, Jiří; Gyurcsik, B.; Kapitán, Josef; Šebestík, Jaroslav; Bouř, Petr

    2007-01-01

    Roč. 14, č. 1 (2007), s. 45-45 ISSN 1211-5894. [Discussions in Structural Molecular Biology /6./. 29.03.2007-31.03.2007, Nové Hrady] Institutional research plan: CEZ:AV0Z40550506 Keywords : Ala-Ala * vibrational circular dichroism * Raman optical activity * peptides Subject RIV: CF - Physical ; Theoretical Chemistry

  11. SU-E-J-197: A Novel Optical Interstitial Fiber Spectroscopic System for Real-Time Tissue Micro-Vascular Hemodynamics Monitoring.

    Science.gov (United States)

    Zhao, D; Campos, D; Yan, Y; Kimple, R; Jacques, S; van der Kogel, A; Kissick, M

    2012-06-01

    To demonstrate a novel interstitial optical fiber spectroscopic system, based on diffuse optical spectroscopies with spectral fitting, for the simultaneous monitoring of tumor blood volume and oxygen tension. The technique provides real-time, minimally-invasive and quantification of tissue micro-vascular hemodynamics. An optical fiber prototype probe characterizesthe optical transport in tissue between two large Numerical Aperture (NA) fibers of 200μm core diameter (BFH37-200, ThorLabs) spaced 3-mm apart. Two 21-Ga medical needles are used to protect fiber ends and to facilitate tissue penetration with minimum local blunt trauma in nude mice with xenografts. A 20W white light source (HL-2000-HP, Ocean Optics) is coupled to one fiber with SMA adapter. The other fiber is used to collect light, which is coupled into the spectrometer (QE65000 with Spectrasuite Operating software and OmniDriver, Ocean Optics). The wavelength response of the probe depends on the wavelength dependence of the light source, and of the light signal collection that includes considerable scatter, modeled with Monte-Carlo techniques (S. Jacques 2010 J. of Innov. Opt. Health Sci. 2 123-9). Measured spectra of tissue are normalized by a measured spectrum of a white standard, yielding the transmission spectrum. A head-and-neck xenograft on the flank of a live mouse is used for development. The optical fiber probe delivers and collects light at an arbitrary depth in the tumor. By spectral fitting of the measured transmission spectrum, an analysis of blood volume and oxygen tension is obtained from the fitting parameters in real time. A newly developed optical fiber spectroscopic system with an optical fiber probe takes spectroscopic techniques to a much deeper level in a tumor, which has potential applications for real-time monitoring hypoxic cell population dynamics for an eventual adaptive therapy metric of particular use in hypofractionated radiotherapy. © 2012 American Association of

  12. Optical spectroscopic characterization of amorphous germanium carbide materials obtained by X-Ray Chemical Vapor Deposition

    Directory of Open Access Journals (Sweden)

    Paola Antoniotti

    2015-05-01

    Full Text Available Amorphous germanium carbides have been prepared by X-ray activated Chemical Vapor Deposition from germane/allene systems. The allene percentage and irradiation time (total dose were correlated to the composition, the structural features, and the optical coefficients of the films, as studied by IR and UV-VIS spectroscopic techniques. The materials composition is found to change depending on both the allene percentage in the mixture and the irradiation time. IR spectroscopy results indicate that the solids consist of randomly bound networks of carbon and germanium atoms with hydrogen atoms terminating all the dangling bonds. Moreover, the elemental analysis results, the absence of both unsaturated bonds and CH3 groups into the solids and the absence of allene autocondensation reactions products, indicate that polymerization reactions leading to mixed species, containing Ge-C bonds, are favored. Eopt values around 3.5 eV have been found in most of the cases, and are correlated with C sp3-bonding configuration. The B1/2 value, related to the order degree, has been found to be dependent on solid composition, atoms distribution in the material and hydrogenation degree of carbon atoms.

  13. Nonlinear optical techniques for surface studies

    International Nuclear Information System (INIS)

    Shen, Y.R.

    1981-09-01

    Recent effort in developing nonlinear optical techniques for surface studies is reviewed. Emphasis is on monolayer detection of adsorbed molecules on surfaces. It is shown that surface coherent antiStokes Raman scattering (CARS) with picosecond pulses has the sensitivity of detecting submonolayer of molecules. On the other hand, second harmonic or sum-frequency generation is also sensitive enough to detect molecular monolayers. Surface-enhanced nonlinear optical effects on some rough metal surfaces have been observed. This facilitates the detection of molecular monolayers on such surfaces, and makes the study of molecular adsorption at a liquid-metal interface feasible. Advantages and disadvantages of the nonlinear optical techniques for surface studies are discussed

  14. Dental diagnostics using optical coherence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Nathel, H. [Lawrence Livermore National Lab., CA (United States); Colston, B. [Univ. of California, San Francisco, CA (United States); Armitage, G. [Univ. of California, Davis, CA (United States)] [and others

    1994-11-15

    Optical radiation can be used for diagnostic purposes in oral medicine. However, due to the turbid, amorphous, and inhomogeneous nature of dental tissue conventional techniques used to transilluminate materials are not well suited to dental tissues. Optical coherence techniques either in the time- of frequency-domain offer the capabilities of discriminating scattered from unscattered light, thus allowing for imaging through turbid tissue. Currently, using optical time-domain reflectometry we are able to discriminate specular from diffuse reflections occurring at tissue boundaries. We have determined the specular reflectivity of enamel and dentin to be approximately 6.6 x 10{sup -5} and 1.3 x 10{sup -6}, respectively. Implications to periodontal imaging will be discussed.

  15. Optical properties of gold island films-a spectroscopic ellipsometry study

    Energy Technology Data Exchange (ETDEWEB)

    Loncaric, Martin, E-mail: mloncaric@irb.hr; Sancho-Parramon, Jordi; Zorc, Hrvoje

    2011-02-28

    Metal island films of noble metals are obtained by deposition on glass substrates during the first stage of evaporation process when supported metal nanoparticles are formed. These films show unique optical properties, owing to the localized surface plasmon resonance of free electrons in metal nanoparticles. In the present work we study the optical properties of gold metal island films deposited on glass substrates with different mass thicknesses at different substrate temperatures. The optical characterization is performed by spectroscopic ellipsometry at different angles of incidence and transmittance measurements at normal incidence in the same point of the sample. Fitting of the ellipsometric data allows determining the effective optical constants and thickness of the island film. A multiple oscillator approach was used to successfully represent the dispersion of the effective optical constants of the films.

  16. Laser and optical techniques employed in enviromental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Sunesson, A

    1988-03-01

    Monitoring of trace gases in the atmosphere has been performed with differential absorption lidar and differential optical absorption spectroscopy. A new mobile differential absorption lidar system has been constructed it is described in detail and examples of SO/sub 2/ and NO/sub 2/ measurements are given. Studies of the NO/sub 2/ concentration distribution in an urban area during a temperature inversion were performed. Detection of CI/sub 2/ with DIAL was investigated. Using a narrow-bandwidth laser system range-resolved measurements of NO and Hg were investigated. Mapping of NO and Hg plumes was performed. The use of mercury as a tracer gas for geothermal energy exploration was investigated during a field test in Iceland. Contrary to expectations very low mercury concentrations were detected. A high-resolution differential optical absorption system has been constructed and applied in longh-path monitoring of SO/sub 2/ and NO/sub 2/. Detection of atmospheric atomic mercury was investigated. A multipass absorption cell (White cell) has been constructed and used for spectroscopic measurements. Weak oxygen absorption lines in the vicinity of the Hg line were studied both with laser and optical techniques. (With 176 refs.)

  17. Optical spectroscopic characterization of human meniscus biomechanical properties

    Science.gov (United States)

    Ala-Myllymäki, Juho; Danso, Elvis K.; Honkanen, Juuso T. J.; Korhonen, Rami K.; Töyräs, Juha; Afara, Isaac O.

    2017-12-01

    This study investigates the capacity of optical spectroscopy in the visible (VIS) and near-infrared (NIR) spectral ranges for estimating the biomechanical properties of human meniscus. Seventy-two samples obtained from the anterior, central, and posterior locations of the medial and lateral menisci of 12 human cadaver joints were used. The samples were subjected to mechanical indentation, then traditional biomechanical parameters (equilibrium and dynamic moduli) were calculated. In addition, strain-dependent fibril network modulus and permeability strain-dependency coefficient were determined via finite-element modeling. Subsequently, absorption spectra were acquired from each location in the VIS (400 to 750 nm) and NIR (750 to 1100 nm) spectral ranges. Partial least squares regression, combined with spectral preprocessing and transformation, was then used to investigate the relationship between the biomechanical properties and spectral response. The NIR spectral region was observed to be optimal for model development (83.0%≤R2≤90.8%). The percentage error of the models are: Eeq (7.1%), Edyn (9.6%), Eɛ (8.4%), and Mk (8.9%). Thus, we conclude that optical spectroscopy in the NIR range is a potential method for rapid and nondestructive evaluation of human meniscus functional integrity and health in real time during arthroscopic surgery.

  18. Spectroscopic Classification of Nine Optical Transients with the 2.5-m du Pont Telescope

    Science.gov (United States)

    Bose, Subhash; Holoien, Tom; Prieto, Jose L.; Dong, Subo; Chen, P.; Stanek, K. Z.

    2018-04-01

    We report spectroscopic observations and classifications of optical transients using the du Pont 2.5-m telescope (+ WFCCD) at Las Campanas Observatory. Targets were discovered by the All-Sky Automated Survey for Supernovae (ASAS-SN, Shappee et al. 2014) (ATel #11391, ATel #11343, ATel #11459), Gaia Alerts (http://gsaweb.ast.cam.ac.uk/alerts/alertsindex) and A. Rest et al. (for 2018agk).

  19. Structural analysis of irradiated crotoxin by spectroscopic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Karina C. de; Fucase, Tamara M.; Silva, Ed Carlos S. e; Chagas, Bruno B.; Buchi, Alisson T.; Viala, Vincent L.; Spencer, Patrick J.; Nascimento, Nanci do, E-mail: kcorleto@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Biotecnologia

    2013-07-01

    Snake bites are a serious public health problem, especially in subtropical countries. In Brazil, the serum, the only effective treatment in case of snake bites, is produced in horses which, despite of their large size, have a reduced lifespan due to the high toxicity of the antigen. Ionizing radiation has been successfully employed to attenuate the biological activity of animal toxins. Crotoxin, the main toxic compound from Crotalus durissus terrificus (Cdt), is a heterodimeric protein composed of two subunits: crotapotin and phospholipase A{sub 2}. Previous data indicated that this protein, following irradiation process, undergoes unfolding and/or aggregation, resulting in a much lower toxic antigen. The exact mechanisms and structural modifications involved in aggregation process are not clear yet. This work investigates the effects of ionizing radiation on crotoxin employing Infrared Spectroscopy, Circular Dichroism and Dynamic Light Scattering techniques. The infrared spectrum of lyophilized crotoxin showed peaks corresponding to the vibrational spectra of the secondary structure of crotoxin, including β-sheet, random coil, α-helix and β-turns. We calculated the area of these spectral regions after adjusting for baseline and normalization using the amide I band (1590-1700 cm{sup -1}), obtaining the variation of secondary structures of the toxin following irradiation. The Circular Dichroism spectra of native and irradiated crotoxin suggests a conformational change within the molecule after the irradiation process. This data indicates structural changes between the samples, apparently from ordered conformation towards a random coil. The analyses by light scattering indicated that the irradiated crotoxin formed multimers with an average molecular radius 100 folds higher than the native toxin. (author)

  20. Structural analysis of irradiated crotoxin by spectroscopic techniques

    International Nuclear Information System (INIS)

    Oliveira, Karina C. de; Fucase, Tamara M.; Silva, Ed Carlos S. e; Chagas, Bruno B.; Buchi, Alisson T.; Viala, Vincent L.; Spencer, Patrick J.; Nascimento, Nanci do

    2013-01-01

    Snake bites are a serious public health problem, especially in subtropical countries. In Brazil, the serum, the only effective treatment in case of snake bites, is produced in horses which, despite of their large size, have a reduced lifespan due to the high toxicity of the antigen. Ionizing radiation has been successfully employed to attenuate the biological activity of animal toxins. Crotoxin, the main toxic compound from Crotalus durissus terrificus (Cdt), is a heterodimeric protein composed of two subunits: crotapotin and phospholipase A 2 . Previous data indicated that this protein, following irradiation process, undergoes unfolding and/or aggregation, resulting in a much lower toxic antigen. The exact mechanisms and structural modifications involved in aggregation process are not clear yet. This work investigates the effects of ionizing radiation on crotoxin employing Infrared Spectroscopy, Circular Dichroism and Dynamic Light Scattering techniques. The infrared spectrum of lyophilized crotoxin showed peaks corresponding to the vibrational spectra of the secondary structure of crotoxin, including β-sheet, random coil, α-helix and β-turns. We calculated the area of these spectral regions after adjusting for baseline and normalization using the amide I band (1590-1700 cm -1 ), obtaining the variation of secondary structures of the toxin following irradiation. The Circular Dichroism spectra of native and irradiated crotoxin suggests a conformational change within the molecule after the irradiation process. This data indicates structural changes between the samples, apparently from ordered conformation towards a random coil. The analyses by light scattering indicated that the irradiated crotoxin formed multimers with an average molecular radius 100 folds higher than the native toxin. (author)

  1. Optical and digital techniques for information security

    CERN Document Server

    2005-01-01

    Optical and Digital Techniques for Information Security is the first book in a series focusing on Advanced Sciences and Technologies for Security Applications. This book encompases the results of research investigation and technologies used to secure, verify, recognize, track, and authenticate objects and information from theft, counterfeiting, and manipulation by unauthorized persons and agencies. This Information Security book will draw on the diverse expertise in optical sciences and engineering, digital image processing, imaging systems, information processing, computer based information systems, sensors, detectors, and biometrics to report innovative technologies that can be applied to information security issues. The Advanced Sciences and Technologies for Security Applications series focuses on research monographs in the areas of: -Recognition and identification (including optical imaging, biometrics, authentication, verification, and smart surveillance systems) -Biological and chemical threat detection...

  2. Fundamentals and techniques of nonimaging optics research

    Science.gov (United States)

    Winston, R.; Ogallagher, J.

    1987-07-01

    Nonimaging Optics differs from conventional approaches in its relaxation of unnecessary constraints on energy transport imposed by the traditional methods for optimizing image formation and its use of more broadly based analytical techniques such as phase space representations of energy flow, radiative transfer analysis, thermodynamic arguments, etc. Based on these means, techniques for designing optical elements which approach and in some cases attain the maximum concentration permitted by the Second Law of Thermodynamics were developed. The most widely known of these devices are the family of Compound Parabolic Concentrators (CPC's) and their variants and the so called Flow-Line or trumpet concentrator derived from the geometric vector flux formalism developed under this program. Applications of these and other such ideal or near-ideal devices permits increases of typically a factor of four (though in some cases as much as an order of magnitude) in the concentration above that possible with conventional means. Present efforts can be classed into two main areas: (1) classical geometrical nonimaging optics, and (2) logical extensions of nonimaging concepts to the physical optics domain.

  3. Optical and spectroscopic properties of Eu-doped tellurite glasses and glass ceramics

    International Nuclear Information System (INIS)

    Stambouli, W.; Elhouichet, H.; Gelloz, B.; Férid, M.

    2013-01-01

    Tellurite glasses doped with trivalent europium were prepared by the conventional melt quenching technique, in the chemical composition of (85−x) TeO 2 +5La 2 O 3 +10TiO 2 +xEu 2 O 3 by varying the concentration of the rare-earth ion in the order 0.5, 1 and 1.5 mol%. Using Judd–Ofelt analysis, we calculated intensity parameters (Ω 2 and Ω 4 ), spontaneous emission probabilities, the radiative lifetime, luminescence branching factors, the quantum yield of luminescence, and the stimulated emission cross-sections for 5 D 0 → 7 F 2 transition. The change in optical properties with the variation of Eu 3+ ion concentration have been discussed and compared with other glasses. The luminescence intensity ratio, quantum efficiency and emission cross-section values support that the TeEu1.5 tellurite glass is a suitable candidate for red laser source applications. Optical properties for Eu 3+ doped tellurite glass, heated for different temperature, were investigated. Crystalline phases for α-TeO 2 , γ-TeO 2 and TiTe 3 O 8 system were determined by the XRD method. The effect of heat treatment on luminescence properties in the tellurite glass was discussed. By using Eu 3+ as a probe, the local structure of rare-earth ion in tellurite glass, vitro-ceramic and ceramic glass has been investigated. The evaluated J–O intensity parameters have been used to calculate different radiative and laser characteristic parameters of the 5 D 0 excited level. The large magnitudes of stimulated emission cross-section (σ e ), branching ratio (β) and Gain bandwidth (σ e ×Δλ eff ) obtained for 5 D 0 → 7 F 2 (613 nm) transition for ceramic glass indicate that the present glass ceramic is promising host material for Eu 3+ doped fiber amplifiers. The measured lifetime of 5 D 0 excited state increases with increase of the heat treatment which further indicate that some Eu 3+ ions were successfully embedded in the crystal phase and prove the low phonon energy environment of Eu 3+ ions

  4. Spectroscopic investigations of lanthanides and actinides using simultaneous LIF and photoionization techniques

    International Nuclear Information System (INIS)

    Shah, M.L.

    2017-01-01

    Laser-induced fluorescence (LIF) and laser-induced photoionization (LIP) are powerful spectroscopic techniques individually. These techniques have been used extensively for studying the atomic spectra. The potential of these two techniques increases enormously when used simultaneously because of their complimentary nature. Among these two, the resonance ionization spectroscopy is most sensitive, but in some cases the spectra obtained using this photoionization technique can provide the incomplete atomic energy levels information. The complete energy level information can be obtained when both the LIF and LIP techniques are used simultaneously. These techniques have been developed in our laboratory. By employing together both the LIF and LIP techniques for simultaneous detection and utilization of LIF and LIP signals not only helped in developing new methodologies but also helped in getting complete spectral information apart from the measurements of atomic parameters. For the first time, laser-induced fluorescence and laser-induced photoionization techniques are used simultaneously for the spectroscopic investigations of atoms of lanthanides and actinides. The density matrix (DM) formalism is used to validate the experimental results. (author)

  5. On the use of the spectroscopic techniques to model the interactions between radionuclides and solid minerals

    Energy Technology Data Exchange (ETDEWEB)

    Simoni, E. [IPN, Paris XI University, 91406 Orsay (France)]. e-mail: simoni@ipno.in2p3.fr

    2004-07-01

    In order to determine the radionuclides sorption constants on solid natural minerals, both thermodynamic and structural investigations, using spectroscopic techniques, are presented. The natural clays, that could be used as engineering barrier in the nuclear waste geological repository, are rather complex minerals. Therefore, in order to understand how these natural materials retain the radionuclides, it is necessary first to perform these studies on simple substrates such as phosphates, oxides and silicates (as powder and single crystal as well) and then extrapolate the obtained results on the natural minerals. As examples, the main results on the sorption processes of the hexavalent uranium onto zircon (ZrSiO{sub 4}) and lanthanum phosphate (LaPO{sub 4}) are presented. The corresponding sorption curves are simulated using the results obtained with the following spectroscopic techniques: laser induced spectro fluorimetry, X-ray photoelectron spectroscopy (XP S), X-ray absorption spectroscopy (Exafs). Finally, the thermodynamic sorption constants are calculated. (Author)

  6. Application of spectroscopic techniques for the study of paper documents: A survey

    International Nuclear Information System (INIS)

    Manso, M.; Carvalho, M.L.

    2009-01-01

    For many centuries paper was the main material for recording cultural achievements all over the world. Paper is mostly made from cellulose with small amounts of organic and inorganic additives, which allow its identification and characterization and may also contribute to its degradation. Prior to 1850, paper was made entirely from rags, using hemp, flax and cotton fibres. After this period, due to the enormous increase in demand, wood pulp began to be commonly used as raw material, resulting in rapid degradation of paper. Spectroscopic techniques represent one of the most powerful tools to investigate the constituents of paper documents in order to establish its identification and its state of degradation. This review describes the application of selected spectroscopic techniques used for paper characterization and conservation. The spectroscopic techniques that have been used and will be reviewed include: Fourier-Transform Infrared spectroscopy, Raman spectroscopy, Nuclear Magnetic Resonance spectroscopy, X-Ray spectroscopy, Laser-based Spectroscopy, Inductively Coupled Mass Spectroscopy, Laser ablation, Atomic Absorption Spectroscopy and X-Ray Photoelectron Spectroscopy.

  7. Optical and spectroscopic properties of neodymium doped cadmium-sodium borate glasses

    Science.gov (United States)

    Mohan, Shaweta; Thind, Kulwant Singh

    2017-10-01

    Neodymium doped cadmium sodium borate glasses having composition xCdO-(40-x) Na2CO3-59.5H3BO3-0.5Nd2O3; x = 10, 20 and 30 mol% were prepared by conventional melt-quenching technique. X-ray diffraction studies confirmed the amorphous nature of the prepared glasses. Conventional methods were used to determine the physical properties such as density, molar volume, refractive index, and rare earth ion concentration. The Judd-Ofelt theory was applied on the optical absorption spectra of the glasses to evaluate the three phenomenological intensity parameters Ω2, Ω4 and Ω6. The calculated intensity parameters were further used to predict the radiative transition probability (A), radiative lifetime (τR) and branching ratio (βR) for the various fluorescent levels of Nd3+ ion in the prepared glass series. The effect of the compositional changes on the spectroscopic characteristics of Nd3+ ions have been studied and reported. The value of Ω2 is found to decrease with the decrease in the sodium content and the corresponding increase in the cadmium content. This can be ascribed to the changes in the asymmetry of the ligand field at the rare earth ion site and the change in rare earth oxygen (RE-O) covalency. Florescence spectra has been used to determine the peak wavelength (λp), effective line widths (Δλeff) and stimulated emission cross-section (σp) for the 4F3/2 → 4I9/2,4I11/2,4I13/2 transitions of the Nd3+ ion. The reasonably higher values of branching ratios and stimulated emission cross-section for the prepared glasses points towards the efficacy of these glasses as laser host materials. However, the glass with more sodium content is found to show better lasing properties.

  8. Optical Axis Identification Technique for Free Space Optics Transmission

    Directory of Open Access Journals (Sweden)

    Yuki Tashiro

    2017-07-01

    Full Text Available This paper describes optical axis adjustment technique for an active free space optics transmission system. This system precisely controls the direction of a collimated thin laser beam using a motor driven laser emitting mechanism and positioning photodiodes. Before beginning laser beam feedback control, it is required to guide the laser beam within the range of the positioning photodiodes for initial laser beam alignment. This paper proposes an arrival position presumption method of laser beam traveling along the long distance from transmitter. A positioning sensor containing several photodiodes measures laser luminescence distribution, and analytically calculates the optical axis of laser beam according to the modified Gaussian beam optics based on four or five distributed local intensity of laser luminescence. Experiments are conducted to evaluate the accuracy of the presumption, and results reveal that the method is effective in leading the laser beam onto a distant receiver.

  9. Electro-optic techniques for VLSI interconnect

    Science.gov (United States)

    Neff, J. A.

    1985-03-01

    A major limitation to achieving significant speed increases in very large scale integration (VLSI) lies in the metallic interconnects. They are costly not only from the charge transport standpoint but also from capacitive loading effects. The Defense Advanced Research Projects Agency, in pursuit of the fifth generation supercomputer, is investigating alternatives to the VLSI metallic interconnects, especially the use of optical techniques to transport the information either inter or intrachip. As the on chip performance of VLSI continues to improve via the scale down of the logic elements, the problems associated with transferring data off and onto the chip become more severe. The use of optical carriers to transfer the information within the computer is very appealing from several viewpoints. Besides the potential for gigabit propagation rates, the conversion from electronics to optics conveniently provides a decoupling of the various circuits from one another. Significant gains will also be realized in reducing cross talk between the metallic routings, and the interconnects need no longer be constrained to the plane of a thin film on the VLSI chip. In addition, optics can offer an increased programming flexibility for restructuring the interconnect network.

  10. Optical techniques for in-core measurements

    International Nuclear Information System (INIS)

    Brichard, B.

    2007-01-01

    The in-situ measurement of dimensional changes is a key issue for advanced irradiation programs in Material Test Reactors. It is for example crucial to monitor the changes of the dimensions of nuclear fuel assemblies as well as those of mechanically stressed structural material samples during in-pile irradiations. Different techniques already exist to carry out such measurements but they all come with a number of drawbacks. SCK-CEN and CEA have therefore decided to share the development of a measurement system that was never applied before in the core of a nuclear reactor. It relies on optical dimensional measurements and brings along unprecedented non-intrusiveness combined with high resolution. A clear advantage in using compact optical sensors results in a more efficient occupation of the irradiation volume available for target testings as well as a significant reduction of the gamma-heating associated with the in-pile instrumentation. The objectives of these shared studies are to design, develop, test and qualify an in-pile dimensional measurement system based on optical techniques, with the goal to implement this system in future MTR irradiation experiments. In 2006, we focussed our activities on sensor analysis, selection of the sensor prototypes, procurement and first irradiation experiment

  11. Optical properties of LiGaS2: an ab initio study and spectroscopic ellipsometry measurement

    International Nuclear Information System (INIS)

    Atuchin, V V; Lin, Z S; Isaenko, L I; Lobanov, S I; Kesler, V G; Kruchinin, V N

    2009-01-01

    Electronic and optical properties of lithium thiogallate crystal, LiGaS 2 , have been investigated by both experimental and theoretical methods. The plane-wave pseudopotential method based on DFT theory has been used for band structure calculations. The electronic parameters of Ga 3d orbitals have been corrected by the DFT+U methods to be consistent with those measured with x-ray photoemission spectroscopy. Evolution of optical constants of LiGaS 2 over a wide spectral range was determined by developed first-principles theory and dispersion curves were compared with optical parameters defined by spectroscopic ellipsometry in the photon energy range 1.2-5.0 eV. Good agreement has been achieved between theoretical and experimental results.

  12. Machine learning techniques for optical communication system optimization

    DEFF Research Database (Denmark)

    Zibar, Darko; Wass, Jesper; Thrane, Jakob

    In this paper, machine learning techniques relevant to optical communication are presented and discussed. The focus is on applying machine learning tools to optical performance monitoring and performance prediction.......In this paper, machine learning techniques relevant to optical communication are presented and discussed. The focus is on applying machine learning tools to optical performance monitoring and performance prediction....

  13. Spectroscopic techniques in the study of human tissues and their components. Part I: IR spectroscopy.

    Science.gov (United States)

    Olsztyńska-Janus, Sylwia; Szymborska-Małek, Katarzyna; Gąsior-Głogowska, Marlena; Walski, Tomasz; Komorowska, Małgorzata; Witkiewicz, Wojciech; Pezowicz, Celina; Kobielarz, Magdalena; Szotek, Sylwia

    2012-01-01

    Among the currently used methods of monitoring human tissues and their components many types of research are distinguished. These include spectroscopic techniques. The advantage of these techniques is the small amount of sample required, the rapid process of recording the spectra, and most importantly in the case of biological samples - preparation of tissues is not required. In this work, vibrational spectroscopy: ATR-FTIR and Raman spectroscopy will be used. Studies are carried out on tissues: tendons, blood vessels, skin, red blood cells and biological components: amino acids, proteins, DNA, plasma, and deposits.

  14. Compact Optical Technique for Streak Camera Calibration

    International Nuclear Information System (INIS)

    Bell, P; Griffith, R; Hagans, K; Lerche, R; Allen, C; Davies, T; Janson, F; Justin, R; Marshall, B; Sweningsen, O

    2004-01-01

    The National Ignition Facility (NIF) is under construction at the Lawrence Livermore National Laboratory (LLNL) for the U.S. Department of Energy Stockpile Stewardship Program. Optical streak cameras are an integral part of the experimental diagnostics instrumentation. To accurately reduce data from the streak cameras a temporal calibration is required. This article describes a technique for generating trains of precisely timed short-duration optical pulses1 (optical comb generators) that are suitable for temporal calibrations. These optical comb generators (Figure 1) are used with the LLNL optical streak cameras. They are small, portable light sources that produce a series of temporally short, uniformly spaced, optical pulses. Comb generators have been produced with 0.1, 0.5, 1, 3, 6, and 10-GHz pulse trains of 780-nm wavelength light with individual pulse durations of ∼25-ps FWHM. Signal output is via a fiber-optic connector. Signal is transported from comb generator to streak camera through multi-mode, graded-index optical fibers. At the NIF, ultra-fast streak-cameras are used by the Laser Fusion Program experimentalists to record fast transient optical signals. Their temporal resolution is unmatched by any other transient recorder. Their ability to spatially discriminate an image along the input slit allows them to function as a one-dimensional image recorder, time-resolved spectrometer, or multichannel transient recorder. Depending on the choice of photocathode, they can be made sensitive to photon energies from 1.1 eV to 30 keV and beyond. Comb generators perform two important functions for LLNL streak-camera users. First, comb generators are used as a precision time-mark generator for calibrating streak camera sweep rates. Accuracy is achieved by averaging many streak camera images of comb generator signals. Time-base calibrations with portable comb generators are easily done in both the calibration laboratory and in situ. Second, comb signals are applied

  15. Application of spectroscopic techniques in the radiation dosimetry of glasses: An update

    International Nuclear Information System (INIS)

    Natarajan, V

    2009-01-01

    The colorimetry and thermoluminescence properties of gamma irradiated glass were reported in as early as 1920. The utility of radio-photoluminescence (RPL) of silver activated metaphosphate glass for monitoring high doses of accidental and routine gamma radiation was reported in the 1960s. Since then considerable amount of research work has been carried out to study the thermoluminescence (TL), optical absorption (OA), electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) of different commercially available glasses for high as well as low dose applications. A brief review of the progress made in the spectroscopic studies of glasses during the past few decades and the application of glasses for radiation dosimetry has been given in this paper.

  16. Application of spectroscopic techniques in the radiation dosimetry of glasses: An update

    Energy Technology Data Exchange (ETDEWEB)

    Natarajan, V, E-mail: vnatra@yahoo.co.in [Radiochemistry Division, Bhabha Atomic Research Centre, Mumbai 40085 (India)

    2009-07-15

    The colorimetry and thermoluminescence properties of gamma irradiated glass were reported in as early as 1920. The utility of radio-photoluminescence (RPL) of silver activated metaphosphate glass for monitoring high doses of accidental and routine gamma radiation was reported in the 1960s. Since then considerable amount of research work has been carried out to study the thermoluminescence (TL), optical absorption (OA), electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) of different commercially available glasses for high as well as low dose applications. A brief review of the progress made in the spectroscopic studies of glasses during the past few decades and the application of glasses for radiation dosimetry has been given in this paper.

  17. Monitoring, controlling and safeguarding radiochemical streams at spent fuel reprocessing facilities with optical and gamma-ray spectroscopic methods

    International Nuclear Information System (INIS)

    Schwantes, J.M.; Bryan, S.A.; Orton, C.R.; Levitskaia, T.G.; Fraga, C.G.

    2013-01-01

    The International Atomic Energy Agency (IAEA) has established international safeguards standards for fissionable material at spent fuel reprocessing plants to ensure that significant quantities of weapons-usable nuclear material are not diverted from these facilities. For large throughput nuclear facilities, it is difficult to satisfy the IAEA safeguards accountancy goal for detection of abrupt diversion. Currently, methods to verify material control and accountancy (MCA) at these facilities require time-consuming and resource intensive destructive assay (DA). Leveraging new on-line non-destructive assay (NDA) process monitoring techniques in conjunction with the traditional and highly precise DA methods may provide an additional measure to nuclear material accountancy which would potentially result in a more timely, cost-effective and resource efficient means for safeguards verification at such facilities. By monitoring process control measurements (e.g. flowrates, temperatures, or concentrations of reagents, products or wastes), abnormal plant operations can be detected. Pacific Northwest National Laboratory (PNNL) is developing on-line NDA process monitoring technologies based upon gamma-ray and optical spectroscopic measurements to potentially reduce the time and resource burden associated with current techniques. The Multi-Isotope Process (MIP) Monitor uses gamma spectroscopy and multivariate analysis to identify off-normal conditions in process streams. The spectroscopic monitor continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major stable flowsheet reagents using UV-Vis, Near IR and Raman spectroscopy. Multi-variate analysis is also applied to the optical measurements in order to quantify concentrations of analytes of interest within a complex array of radiochemical streams. This paper will provide an overview of these methods and reports on-going efforts to develop

  18. Correlated topographic and spectroscopic imaging by combined atomic force microscopy and optical microscopy

    International Nuclear Information System (INIS)

    Hu Dehong; Micic, Miodrag; Klymyshyn, Nicholas; Suh, Y.D.; Lu, H.P.

    2004-01-01

    Near-field scanning microscopy is a powerful approach to obtain topographic and spectroscopic characterization simultaneously for imaging biological and nanoscale systems. To achieve optical imaging at high spatial resolution beyond the diffraction limit, aperture-less metallic scanning tips have been utilized to enhance the laser illumination local electromagnetic field at the apex of the scanning tips. In this paper, we discuss and review our work on combined fluorescence imaging with AFM-metallic tip enhancement, finite element method simulation of the tip enhancement, and their applications on AFM-tip enhanced fluorescence lifetime imaging (AFM-FLIM) and correlated AFM and FLIM imaging of the living cells

  19. Application of spectroscopic techniques to the study of illuminated manuscripts: A survey

    International Nuclear Information System (INIS)

    Pessanha, S.; Manso, M.; Carvalho, M.L.

    2012-01-01

    This work focused on the application of the most relevant spectroscopic techniques used for the characterization of illuminated manuscripts. The historical value of these unique and invaluable artworks, together with the increased awareness concerning the conservation of cultural heritage, prompted the application of analytical techniques to the study of these illuminations. This is essential for the understanding of the artist's working methods, which aids conservation–restoration. The characterization of the pigments may also help assign a probable date to the manuscript. For these purposes, the spectroscopic techniques used so far include those that provide information on the elemental content: X-ray fluorescence, total reflection X-ray fluorescence and scanning electron microscopy coupled with energy-dispersive spectroscopy and laser-induced breakdown spectroscopy. Complementary techniques, such as X-ray diffraction, Fourier transform infrared and Raman spectroscopy, reveal information regarding the compounds present in the samples. The techniques, suitability, technological evolution and development of high-performance detectors, as well as the possibility of microanalysis and the higher sensitivity of the equipment, will also be discussed. Furthermore, issues such as the necessity of sampling, the portability of the equipment and the overall advantages and disadvantages of different techniques will be analyzed. - Highlights: ► The techniques used for studying illuminated manuscripts are described and compared. ► For in situ, non-destructive analysis the most suitable technique is EDXRF. ► For quantitative analysis TXRF is more appropriate. ► Raman spectroscopy is mostly used for pigments identification. ► FTIR was used for the characterization of binders and parchment.

  20. Synthesis, structure, spectroscopic investigations, and computational studies of optically pure β-ketoamide

    International Nuclear Information System (INIS)

    Mtat, D.; Touati, R.; Guerfel, T.; Walha, K.; Ben Hassine, B.

    2016-01-01

    Chemical preparation, X-ray single crystal diffraction, IR and NMR spectroscopic investigations of a novel nonlinear optical organic compound (C 17 H 22 NO 2 Cl) are described. The compound crystallizes in the orthorhombic system with the non-centrosymmetric sp. gr. P2 1 2 1 2 1 . In the crystal structure, molecules are interconnected by N–H…O hydrogen bonds forming infinite chains along a axis. The Hirshfeld surface and associated fingerprint plots of the compound are presented to explore the nature of intermolecular interactions and their relative contributions in building the solid-state architecture. The molecular HOMO–LUMO compositions and their respective energy gaps are also drawn to explain the activity of the compound. The first hyperpolarizability β tot of the title compound is determined using DFT calculations. The optical properties are also investigated by UV–Vis absorption spectrum.

  1. Synthesis, structure, spectroscopic investigations, and computational studies of optically pure β-ketoamide

    Energy Technology Data Exchange (ETDEWEB)

    Mtat, D.; Touati, R. [Université de Monastir, Laboratoire de Synthèse Organique Asymétrique et Catalyse Homogène (UR11ES56), Faculté des Sciences (Tunisia); Guerfel, T., E-mail: taha-guerfel@yahoo.fr [Université de Kairouan, Laboratoire d’Electrochimie, Matériaux et Environnement (Tunisia); Walha, K. [Université de Sfax, M.E.S.Lab. Faculté des Sciences de Sfax (Tunisia); Ben Hassine, B. [Université de Monastir, Laboratoire de Synthèse Organique Asymétrique et Catalyse Homogène (UR11ES56), Faculté des Sciences (Tunisia)

    2016-12-15

    Chemical preparation, X-ray single crystal diffraction, IR and NMR spectroscopic investigations of a novel nonlinear optical organic compound (C{sub 17}H{sub 22}NO{sub 2}Cl) are described. The compound crystallizes in the orthorhombic system with the non-centrosymmetric sp. gr. P2{sub 1}2{sub 1}2{sub 1}. In the crystal structure, molecules are interconnected by N–H…O hydrogen bonds forming infinite chains along a axis. The Hirshfeld surface and associated fingerprint plots of the compound are presented to explore the nature of intermolecular interactions and their relative contributions in building the solid-state architecture. The molecular HOMO–LUMO compositions and their respective energy gaps are also drawn to explain the activity of the compound. The first hyperpolarizability β{sub tot} of the title compound is determined using DFT calculations. The optical properties are also investigated by UV–Vis absorption spectrum.

  2. X-ray computer tomography, ultrasound and vibrational spectroscopic evaluation techniques of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Baldock, Clive

    2004-01-01

    Since Gore et al published their paper on Fricke gel dosimetry, the predominant method of evaluation of both Fricke and polymer gel dosimeters has been magnetic resonance imaging (MRI). More recently optical computer tomography (CT) has also been a favourable evaluation method. Other techniques have been explored and developed as potential evaluation techniques in gel dosimetry. This paper reviews these other developments

  3. Probing the interactions of mitoxantrone with biomimetic membranes with electrochemical and spectroscopic techniques

    International Nuclear Information System (INIS)

    Nieciecka, Dorota; Królikowska, Agata; Krysinski, Paweł

    2015-01-01

    Graphical abstract: Display Omitted - Abstract: Mitoxantrone – an anticancer drug – was used to probe the interactions of this class of cytostatic molecules with biomimetic monolayers. The drug effect was monitored with electrochemical (cyclic voltammetry and electrochemical impedance spectroscopy), as well as spectroscopic techniques (surface enhanced Raman scattering), during its passive partitioning/penetration through the mixed Langmuir and Langmuir–Blodgett monolayers after their transfer on gold electrodes. This approach allowed us to discriminate between the drug interactions with hydrophilic head-group region and hydrophobic alkyl chains moiety of such monolayers

  4. A rapid method of radium-226 analysis in water samples using an alpha spectroscopic technique

    International Nuclear Information System (INIS)

    Lim, T.P.

    1981-01-01

    A fast, reliable and accurate method for radium-226 determination in environmental water samples has been devised, using an alpha spectroscopic technique. The correlation between barium-133 and radium-226 in the barium-radium sulphate precipitation mechanism was studied and in the limited experimental recovery range, the coefficient of correlation was r = 0.986. A self-absorption study for various barium carrier concentrations was also undertaken to obtain the least broadening of alpha energy line widths. An optimum value of 0.3 mg barium carrier was obtained for chemical recovery in the range of 85 percent. (auth)

  5. Optical and spectroscopic studies on tannery wastes as a possible source of organic semiconductors

    Science.gov (United States)

    Nashy, El-Shahat H. A.; Al-Ashkar, Emad; Abdel Moez, A.

    2012-02-01

    Tanning industry produces a large quantity of solid wastes which contain hide proteins in the form of protein shavings containing chromium salts. The chromium wastes are the main concern from an environmental stand point of view, because chrome wastes posses a significant disposal problem. The present work is devoted to investigate the possibility of utilizing these wastes as a source of organic semi-conductors as an alternative method instead of the conventional ones. The chemical characterization of these wastes was determined. In addition, the Horizontal Attenuated Total Reflection (HATR) FT-IR spectroscopic analysis and optical parameters were also carried out for chromated samples. The study showed that the chromated samples had suitable absorbance and transmittance in the wavelength range (500-850 nm). Presence of chromium salt in the collagen samples increases the absorbance which improves the optical properties of the studied samples and leads to decrease the optical energy gap. The obtained optical energy gap gives an impression that the environmentally hazardous chrome shavings wastes can be utilized as a possible source of natural organic semiconductors with direct and indirect energy gap. This work opens the door to use some hazardous wastes in the manufacture of electronic devices such as IR-detectors, solar cells and also as solar cell windows.

  6. Performance assessment of diffuse optical spectroscopic imaging instruments in a 2-year multicenter breast cancer trial

    Science.gov (United States)

    Leproux, Anaïs; O'Sullivan, Thomas D.; Cerussi, Albert; Durkin, Amanda; Hill, Brian; Hylton, Nola; Yodh, Arjun G.; Carp, Stefan A.; Boas, David; Jiang, Shudong; Paulsen, Keith D.; Pogue, Brian; Roblyer, Darren; Yang, Wei; Tromberg, Bruce J.

    2017-12-01

    We present a framework for characterizing the performance of an experimental imaging technology, diffuse optical spectroscopic imaging (DOSI), in a 2-year multicenter American College of Radiology Imaging Network (ACRIN) breast cancer study (ACRIN-6691). DOSI instruments combine broadband frequency-domain photon migration with time-independent near-infrared (650 to 1000 nm) spectroscopy to measure tissue absorption and reduced scattering spectra and tissue hemoglobin, water, and lipid composition. The goal of ACRIN-6691 was to test the effectiveness of optically derived imaging endpoints in predicting the final pathologic response of neoadjuvant chemotherapy (NAC). Sixty patients were enrolled over a 2-year period at participating sites and received multiple DOSI scans prior to and during 3- to 6-month NAC. The impact of three sources of error on accuracy and precision, including different operators, instruments, and calibration standards, was evaluated using a broadband reflectance standard and two different solid tissue-simulating optical phantoms. Instruments showed <0.0010 mm-1 (10.3%) and 0.06 mm-1 (4.7%) deviation in broadband absorption and reduced scattering, respectively, over the 2-year duration of ACRIN-6691. These variations establish a useful performance criterion for assessing instrument stability. The proposed procedures and tests are not limited to DOSI; rather, they are intended to provide methods to characterize performance of any instrument used in translational optical imaging.

  7. Optical and spectroscopic studies on tannery wastes as a possible source of organic semiconductors.

    Science.gov (United States)

    Nashy, El-Shahat H A; Al-Ashkar, Emad; Moez, A Abdel

    2012-02-01

    Tanning industry produces a large quantity of solid wastes which contain hide proteins in the form of protein shavings containing chromium salts. The chromium wastes are the main concern from an environmental stand point of view, because chrome wastes posses a significant disposal problem. The present work is devoted to investigate the possibility of utilizing these wastes as a source of organic semi-conductors as an alternative method instead of the conventional ones. The chemical characterization of these wastes was determined. In addition, the Horizontal Attenuated Total Reflection (HATR) FT-IR spectroscopic analysis and optical parameters were also carried out for chromated samples. The study showed that the chromated samples had suitable absorbance and transmittance in the wavelength range (500-850 nm). Presence of chromium salt in the collagen samples increases the absorbance which improves the optical properties of the studied samples and leads to decrease the optical energy gap. The obtained optical energy gap gives an impression that the environmentally hazardous chrome shavings wastes can be utilized as a possible source of natural organic semiconductors with direct and indirect energy gap. This work opens the door to use some hazardous wastes in the manufacture of electronic devices such as IR-detectors, solar cells and also as solar cell windows. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Optical inspection techniques for security instrumentation

    Science.gov (United States)

    van Renesse, Rudolf L.

    1996-03-01

    This paper reviews four optical inspection systems, in which development TNO Institute of Applied Physics was involved: (1) intaglio scanning and recognition, (2) banknote quality inspection, (3) visualization and reading of a finger pattern, and (4) 3DAS authentication. (1) Intaglio is reserved for high security printing. It renders a tactile relief that can be recognized by a laser scanning technique. This technique is applied by various national banks to detect counterfeit banknotes returning from circulation. A new system is proposed that will detect intaglio on arbitrary wrinkled banknotes. (2) A banknote fitness inspection system (BFIS) that inspects banknotes in specularly reflected light is described. As modern banknotes are provided increasingly with reflective security foils, a new system is proposed that inspects banknotes in specular and diffuse reflection, as well as in transmission. (3) An alternative visualization method for visualization of finger patterns is described, employing a reflective elastomer. A CD scanning system reads the finger patterns. (4) A nonwoven structure has two advantageous properties for card authentication: a random structure which renders each few square millimeters of the pattern uniqueness (identification) and a 3D structure which makes it virtually impossible to be counterfeited (authentication). Both properties are inspected by an extremely simple lenseless reader.

  9. Parametrization of optical properties of indium-tin-oxide thin films by spectroscopic ellipsometry: Substrate interfacial reactivity

    Science.gov (United States)

    Losurdo, M.; Giangregorio, M.; Capezzuto, P.; Bruno, G.; de Rosa, R.; Roca, F.; Summonte, C.; Plá, J.; Rizzoli, R.

    2002-01-01

    Indium-tin-oxide (ITO) films deposited by sputtering and e-gun evaporation on both transparent (Corning glass) and opaque (c-Si, c-Si/SiO2) substrates and in c-Si/a-Si:H/ITO heterostructures have been analyzed by spectroscopic ellipsometry (SE) in the range 1.5-5.0 eV. Taking the SE advantage of being applicable to absorbent substrate, ellipsometry is used to determine the spectra of the refractive index and extinction coefficient of the ITO films. The effect of the substrate surface on the ITO optical properties is focused and discussed. To this aim, a parametrized equation combining the Drude model, which considers the free-carrier response at the infrared end, and a double Lorentzian oscillator, which takes into account the interband transition contribution at the UV end, is used to model the ITO optical properties in the useful UV-visible range, whatever the substrate and deposition technique. Ellipsometric analysis is corroborated by sheet resistance measurements.

  10. New scanning technique for the optical vortex microscope.

    Science.gov (United States)

    Augustyniak, Ireneusz; Popiołek-Masajada, Agnieszka; Masajada, Jan; Drobczyński, Sławomir

    2012-04-01

    In the optical vortex microscopy the focused Gaussian beam with optical vortex scans a sample. An optical vortex can be introduced into a laser beam with the use of a special optical element--a vortex lens. When moving the vortex lens, the optical vortex changes its position inside the spot formed by a focused laser beam. This effect can be used as a new precise scanning technique. In this paper, we study the optical vortex behavior at the sample plane. We also estimate if the new scanning technique results in observable effects that could be used for a phase object detection.

  11. Surface diffusion studies by optical diffraction techniques

    International Nuclear Information System (INIS)

    Xiao, X.D.

    1992-11-01

    The newly developed optical techniques have been combined with either second harmonic (SH) diffraction or linear diffraction off a monolayer adsorbate grating for surface diffusion measurement. Anisotropy of surface diffusion of CO on Ni(l10) was used as a demonstration for the second harmonic dim reaction method. The linear diffraction method, which possesses a much higher sensitivity than the SH diffraction method, was employed to study the effect of adsorbate-adsorbate interaction on CO diffusion on Ni(l10) surface. Results showed that only the short range direct CO-CO orbital overlapping interaction influences CO diffusion but not the long range dipole-dipole and CO-NI-CO interactions. Effects of impurities and defects on surface diffusion were further explored by using linear diffraction method on CO/Ni(110) system. It was found that a few percent S impurity can alter the CO diffusion barrier height to a much higher value through changing the Ni(110) surface. The point defects of Ni(l10) surface seem to speed up CO diffusion significantly. A mechanism with long jumps over multiple lattice distance initiated by CO filled vacancy is proposed to explain the observed defect effect

  12. Optical properties and surface characterization of pulsed laser-deposited Cu2ZnSnS4 by spectroscopic ellipsometry

    International Nuclear Information System (INIS)

    Crovetto, Andrea; Cazzaniga, Andrea; Ettlinger, Rebecca B.; Schou, Jørgen; Hansen, Ole

    2015-01-01

    Cu 2 ZnSnS 4 films prepared by pulsed laser deposition at different temperatures are characterized by spectroscopic ellipsometry. The focus is on confirming results from direct measurement techniques, by finding appropriate models of the surface overlayer for data fitting, and extracting the dielectric function of the films. It is found that the surface overlayer changes with film thickness and deposition temperature. Adopting different ellipsometry measurements and modeling strategies for each film, dielectric functions are extracted and compared. As the deposition temperature is increased, the dielectric functions exhibit additional critical points related to optical transitions in the material other than absorption across the fundamental band gap. In the case of a thin film < 200 nm thick, surface features observed by scanning electron microscopy and atomic force microscopy are accurately reproduced by ellipsometry data fitting. - Highlights: • Inhomogeneous Cu 2 ZnSnS 4 films are prepared by pulsed laser deposition. • The film surface includes secondary phases and topographic structures. • We model a film surface layer that fits ellipsometry data. • Ellipsometry data fits confirm results from direct measurement techniques. • We obtain the dielectric function of inhomogeneous Cu 2 ZnSnS 4 films

  13. Optical Measurement Techniques Innovations for Industry and the Life Sciences

    CERN Document Server

    Peiponen, Kai-Erik; Priezzhev, Alexander V

    2009-01-01

    Devoted to novel optical measurement techniques that are applied both in industry and life sciences, this book contributes a fresh perspective on the development of modern optical sensors. These sensors are often essential in detecting and controlling parameters that are important for both industrial and biomedical applications. The book provides easy access for beginners wishing to gain familiarity with the innovations of modern optics.

  14. Compact optical technique for streak camera calibration

    International Nuclear Information System (INIS)

    Bell, Perry; Griffith, Roger; Hagans, Karla; Lerche, Richard; Allen, Curt; Davies, Terence; Janson, Frans; Justin, Ronald; Marshall, Bruce; Sweningsen, Oliver

    2004-01-01

    To produce accurate data from optical streak cameras requires accurate temporal calibration sources. We have reproduced an older technology for generating optical timing marks that had been lost due to component availability. Many improvements have been made which allow the modern units to service a much larger need. Optical calibrators are now available that produce optical pulse trains of 780 nm wavelength light at frequencies ranging from 0.1 to 10 GHz, with individual pulse widths of approximately 25 ps full width half maximum. Future plans include the development of single units that produce multiple frequencies to cover a wide temporal range, and that are fully controllable via an RS232 interface

  15. Compact optical technique for streak camera calibration

    Science.gov (United States)

    Bell, Perry; Griffith, Roger; Hagans, Karla; Lerche, Richard; Allen, Curt; Davies, Terence; Janson, Frans; Justin, Ronald; Marshall, Bruce; Sweningsen, Oliver

    2004-10-01

    To produce accurate data from optical streak cameras requires accurate temporal calibration sources. We have reproduced an older technology for generating optical timing marks that had been lost due to component availability. Many improvements have been made which allow the modern units to service a much larger need. Optical calibrators are now available that produce optical pulse trains of 780 nm wavelength light at frequencies ranging from 0.1 to 10 GHz, with individual pulse widths of approximately 25 ps full width half maximum. Future plans include the development of single units that produce multiple frequencies to cover a wide temporal range, and that are fully controllable via an RS232 interface.

  16. Important hydrodynamic and spectroscopic techniques in the field of chromatin structure

    Energy Technology Data Exchange (ETDEWEB)

    Olins, D. E.

    1978-01-01

    Combining hydrodynamic and spectroscopic techniques in the study of conformational states of ..nu../sub 1/ induced by a variety of perturbants has led us to a general coneption: the two structural domains of ..nu../sub 1/ (i.e., the DNA-rich outer shell and the ..cap alpha..-helix-rich apolar histone core) exhibit differential responsiveness. In general, the ..cap alpha..-helical regions are more resistant, than DNA conformation or ..nu../sub 1/ size and shape, to the perturbing effects of urea, decreased ionic strength and pH, trypsin treatment, or a variety of water-miscible organic solvents. There are a number of reasonable conceptual models to explain this differential responsiveness of the structural domains of ..nu../sub 1/.

  17. Digital processing optical transmission and coherent receiving techniques

    CERN Document Server

    Binh, Le Nguyen

    2013-01-01

    With coherent mixing in the optical domain and processing in the digital domain, advanced receiving techniques employing ultra-high speed sampling rates have progressed tremendously over the last few years. These advances have brought coherent reception systems for lightwave-carried information to the next stage, resulting in ultra-high capacity global internetworking. Digital Processing: Optical Transmission and Coherent Receiving Techniques describes modern coherent receiving techniques for optical transmission and aspects of modern digital optical communications in the most basic lines. The

  18. Optical Imaging and Microscopy Techniques and Advanced Systems

    CERN Document Server

    Török, Peter

    2007-01-01

    This text on contemporary optical systems is intended for optical researchers and engineers, graduate students and optical microscopists in the biological and biomedical sciences. This second edition contains two completely new chapters. In addition most of the chapters from the first edition have been revised and updated. The book consists of three parts: The first discusses high-aperture optical systems, which form the backbone of optical microscopes. An example is a chapter new in the second edition on the emerging field of high numerical aperture diffractive lenses which seems to have particular promise in improving the correction of lenses. In this part particular attention is paid to optical data storage. The second part is on the use of non-linear optical techniques, including nonlinear optical excitation (total internal reflection fluorescence, second and third harmonic generation and two photon microscopy) and non-linear spectroscopy (CARS). The final part of the book presents miscellaneous technique...

  19. Antifouling leaching technique for optical lenses

    Science.gov (United States)

    Strahle, William J.; Perez, C. L.; Martini, Marinna A.

    1994-01-01

    The effectiveness of optical lenses deployed in water less than 100 m deep is significantly reduced by biofouling caused by the settlement of macrofauna, such as barnacles, hydroids, and tunicates. However, machineable porous plastic rings can be used to dispense antifoulant into the water in front of the lens to retard macrofaunal growth without obstructing the light path. Unlike coatings which can degrade the optical performance, antifouling rings do not interfere with the instrument optics. The authors have designed plastic, reusable cup-like antifouling rings to slip over the optical lenses of a transmissometer. These rings have been used for several deployments on shallow moorings in Massachusetts Bay, MA and have increased the time before fouling degrades optical characteristics

  20. Cognitive Heterogeneous Reconfigurable Optical Networks (CHRON): Enabling Technologies and Techniques

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso; Zibar, Darko; Guerrero Gonzalez, Neil

    2011-01-01

    We present the approach of cognition applied to heterogeneous optical networks developed in the framework of the EU project CHRON: Cognitive Heterogeneous Reconfigurable Optical Network. We introduce and discuss in particular the technologies and techniques that will enable a cognitive optical...... network to observe, act, learn and optimizes its performance, taking into account its high degree of heterogeneity with respect to quality of service, transmission and switching techniques....

  1. Multi-spectroscopic techniques to evaluate the toxicity of alloyed CdSeS quantum dots

    International Nuclear Information System (INIS)

    Zhan Hongju; Zhou Peijiang; Ding Ling; He Zhenyu; Ma Rong

    2012-01-01

    Alloyed CdSeS quantum dots (QDs) were successfully synthesized in aqueous phase using microwave irradiation. UV–vis spectroscopy, fluorescence spectroscopy, transmission electron microscopy (TEM) and X-ray diffraction (XRD) techniques proved that the prepared alloyed QDs are composed of a CdSe-rich core and thick CdS shell with homogeneous size distributions. In order to study its biological toxicity, multi-spectroscopic techniques were adopted to investigate their conjugation with BSA. Fluorescence quenching methods indicated the prepared CdSeS QDs strongly quenched the fluorescence of BSA due to the formation of non-fluorescence ground-state complex. UV–vis absorbance spectra, synchronous fluorescence spectra and CD spectra further confirmed the alloyed CdSeS QDs binded with BSA and destroyed their hydrogen bonding networks, which induced the conformation changes of this macromolecule. - Highlights: ► Synthesis of alloyed CdSeS QDs in aqueous phase via microwave irradiation. ► Characterization of alloyed QDs by PL, UV–vis, XRD and TEM techniques. ► Evidence of static quenching between alloyed QDs and BSA. ► Evidence of the conformation change of BSA molecules induced by alloyed QDs.

  2. New focus on Fourier optics techniques

    NARCIS (Netherlands)

    Calvo, M.L.; Alieva, T.; Bastiaans, M.J.; Rodrigo Martín-Romo, J.A.; Rodríguez Merlo, D.; Vlad, V.I.

    2004-01-01

    We present a short overview on the application of fractional cyclic and linear canonical transformations to optical signal processing and dedicate some of the discussions to the particular features found in the fractional Fourier transform domain.

  3. Optical coherence tomography: Technique and applications

    DEFF Research Database (Denmark)

    Thomsen, Jakob Borup; Sander, Birgit; Mogensen, Mette

    2009-01-01

    Optical coherence tomography (OCT) is a noninvasive optical imaging modality providing real-time video rate images in two and three dimensions of biological tissues with micrometer resolution. OCT fills the gap between ultrasound and confocal microscopy, since it has a higher resolution than...... of retinal diseases. The potential of OCT in many other applications is currently being explored, such as in developmental biology, skin cancer diagnostics, vulnerable plaque detection in cardiology, esophageal diagnostics and a number of other applications within oncology....

  4. Synthesis, spectroscopic, structural and optical studies of Ru2S3 nanoparticles prepared from single-source molecular precursors

    Science.gov (United States)

    Mbese, Johannes Z.; Ajibade, Peter A.

    2017-09-01

    Homonuclear tris-dithiocarbamato ruthenium(III) complexes, [Ru(S2CNR2)3] were prepared and characterized by spectroscopic techniques and thermogravimetric analyses. The thermogravimetric analyses (TGA) of the ruthenium complexes showed that the complexes decompose to ruthenium(III) sulfide nanoparticles. The ruthenium(III) complexes were dispersed in oleic acid and thermolysed in hexadecylamine to prepared oleic acid/hexadecylamine capped Ru2S3 nanoparticles. FTIR revealed that Ru2S3 nanoparticles are capped through the interaction of the -NH2 group of hexadecylamine HDA adsorbed on the surfaces of nanoparticles and it also showed that oleic acid (OA) is acting as both coordinating stabilizing surfactant and capping agent. EDS spectra revealed that the prepared nanoparticles are mainly composed of Ru and S, confirming the formation of Ru2S3 nanoparticles. Powder XRD confirms that the nanoparticles are in cubic phase. The inner morphology of nanoparticles obtained from transmission electron microscopy (TEM) showed nanoparticles with narrow particle size distributions characterized by an average diameter of 8.45 nm with a standard deviation of 1.6 nm. The optical band gap (Eg) determined from Tauc plot are in the range 3.44-4.18 eV.

  5. Growth, structural, spectroscopic and optical characterization of barium doped calcium tartrate

    Science.gov (United States)

    Verma, Seema; Raina, Bindu; Gupta, Vandana; Bamzai, K. K.

    2018-05-01

    Barium doped calcium tartrates synthesized by controlled diffusion using silica gel technique at ambient temperature was characterized by single crystal X-ray diffraction which establishes monoclinic crystal system with volume of the unit cell 923.97(10) Ǻ3 and the space group being P21. UV - Vis characterization gives various linear optical constants like absorption, transmittance, reflectance, band gap, extinction coefficient, urbach energy, complex dielectric constant, optical and electrical conductivity. These constants are considered to be essential in characterizing materials that are used in various applications like fabrication of optoelectronic devices. FTIR spectrum establishes the presence of various bands of functional groups expected from metal tartrate with water of crystallization.

  6. Application of spectroscopic techniques for the analysis of kidney stones: a pilot study

    Science.gov (United States)

    Shameem, K. M., Muhammed; Chawla, Arun; Bankapur, Aseefhali; Unnikrishnan, V. K.; Santhosh, C.

    2016-03-01

    Identification and characterization of kidney stone remains one of the important analytical tasks in the medical field. Kidney stone is a common health complication throughout the world, which may cause severe pain, obstruction and infection of urinary tract, and can lead to complete renal damage. It commonly occurs in both sexes regardless of age. Kidney stones have different composition, although each stones have a major single characteristic component. A complete understanding of a sample properties and their function can only be feasible by utilizing elemental and molecular information simultaneously. Two laser based analytical techniques; Laser Induced Breakdown spectroscopy (LIBS) and Raman spectroscopy have been used to study different types of kidney stones from different patients. LIBS and Raman spectroscopy are highly complementary spectroscopic techniques, which provide elemental and molecular information of a sample. Q-switched Nd:YAG laser at 355 nm laser having energy 17mJ per pulse at 10 Hz repetition rate was used for getting LIBS spectra. Raman measurements were carried out using a home assembled micro-Raman spectrometer. Using the recorded Raman spectra of kidney stones, we were able to differentiate different kinds of kidney stones. LIBS spectra of the same stones are showing the evidence of C, Ca, H, and O and also suggest the presence of certain pigments.

  7. An integrated spectroscopic approach for the non-invasive study of modern art materials and techniques

    Science.gov (United States)

    Rosi, F.; Miliani, C.; Clementi, C.; Kahrim, K.; Presciutti, F.; Vagnini, M.; Manuali, V.; Daveri, A.; Cartechini, L.; Brunetti, B. G.; Sgamellotti, A.

    2010-09-01

    A non-invasive study has been carried out on 18 paintings by Alberto Burri (1915-1995), one of Italy’s most important contemporary painters. The study aims to demonstrate the appropriate and suitable use of portable non-invasive instrumentation for the characterization of materials and techniques found in works dating from 1948 to 1975 belonging to the Albizzini Collection. Sampling of any kind has been forbidden, in order to maintain the integrity of the paintings. Furthermore, the material heterogeneity of each single artwork could potentially result in a poorly representative sampling campaign. Therefore, a non-invasive and in situ analytical approach has been deemed mandatory, notwithstanding the complexity of modern materials and challenging data interpretation. It is the non-invasive nature of the study that has allowed for the acquisition of vast spectral data (a total of about 650 spectra including XRF, mid and near FTIR, micro-Raman and UV-vis absorption and emission spectroscopies). In order to better handle and to extrapolate the most meaningful information from these data, a statistical multivariate analysis, namely principal component analysis (PCA), has been applied to the spectral results. In particular, the possibility of combining elemental and molecular information has been explored by uniting XRF and infrared spectra in one PCA dataset. The combination of complementary spectroscopic techniques has allowed for the characterization of both inorganic and organic pigments, extenders, fillers, and binders employed by Alberto Burri.

  8. Monitoring techniques for the manufacture of tapered optical fibers.

    Science.gov (United States)

    Mullaney, Kevin; Correia, Ricardo; Staines, Stephen E; James, Stephen W; Tatam, Ralph P

    2015-10-01

    The use of a range of optical techniques to monitor the process of fabricating optical fiber tapers is investigated. Thermal imaging was used to optimize the alignment of the optical system; the transmission spectrum of the fiber was monitored to confirm that the tapers had the required optical properties and the strain induced in the fiber during tapering was monitored using in-line optical fiber Bragg gratings. Tapers were fabricated with diameters down to 5 μm and with waist lengths of 20 mm using single-mode SMF-28 fiber.

  9. Spectroscopic analysis of optoelectronic semiconductors

    CERN Document Server

    Jimenez, Juan

    2016-01-01

    This book deals with standard spectroscopic techniques which can be used to analyze semiconductor samples or devices, in both, bulk, micrometer and submicrometer scale. The book aims helping experimental physicists and engineers to choose the right analytical spectroscopic technique in order to get specific information about their specific demands. For this purpose, the techniques including technical details such as apparatus and probed sample region are described. More important, also the expected outcome from experiments is provided. This involves also the link to theory, that is not subject of this book, and the link to current experimental results in the literature which are presented in a review-like style. Many special spectroscopic techniques are introduced and their relationship to the standard techniques is revealed. Thus the book works also as a type of guide or reference book for people researching in optical spectroscopy of semiconductors.

  10. Spectroscopic and molecular docking techniques study of the interaction between oxymetholone and human serum albumin

    Energy Technology Data Exchange (ETDEWEB)

    Madrakian, Tayyebeh, E-mail: madrakian@basu.ac.ir; Bagheri, Habibollah; Afkhami, Abbas; Soleimani, Mohammad

    2014-11-15

    In this study, the binding of oxymetholone (OXM), a doping drug, to human serum albumin (HSA) was explored at pH 7.40 by spectroscopic methods including spectrofluorimetry, three dimensional excitation–emission matrix (3D EEM), UV–vis absorption, resonance rayleigh scattering (RRS) and molecular docking. The fluorescence results showed that there was a considerable quenching of the intrinsic fluorescence of HSA upon binding to OXM by static quenching mechanism. The Stern–Volmer quenching constants (K{sub SV}) between OXM and HSA at three different temperatures 295, 303, 308 K, were obtained as 4.63×10{sup 4}, 3.05×10{sup 4} and 1.49×10{sup 4} L mol{sup −1}, respectively. Furthermore this interaction was confirmed by UV–vis spectrophotometric and RRS techniques. The binding site number, n, apparent binding constant, K{sub b}, and corresponding thermodynamic parameters (ΔS, ΔH and ΔG) were measured at different temperatures. The Van der Waals and hydrogen-bond forces were found to stabilize OXM–HSA complex. The distance (r) between the donor and acceptor was obtained from Förster's theory of fluorescence resonance energy transfer (FRET) and found to be 1.67 nm. The 3D EEM showed that OXM slightly changes the secondary structure of HSA. Furthermore, the molecular docking was employed for identification of drug binding sites and interaction of OXM with amino acid residues. - Highlights: • The binding of OXM as a doping drug with HSA was studied by different techniques. • The binding constant of HSA–OXM was calculated. • The binding site of OXM on HSA was characterized with molecular docking. • The thermodynamic parameters were calculated according to fluorescence technique.

  11. Near-field reflection backscattering apertureless optical microscopy: Application to spectroscopy experiments on opaque samples, comparison between lock-in and digital photon counting detection techniques

    International Nuclear Information System (INIS)

    Diziain, S.; Bijeon, J.-L.; Adam, P.-M.; Lamy de la Chapelle, M.; Thomas, B.; Deturche, R.; Royer, P.

    2007-01-01

    An apertureless scanning near-field optical microscope (ASNOM) in reflection backscattering configuration is designed to conduct spectroscopic experiments on opaque samples constituted of latex beads. The ASNOM proposed takes advantage of the depth-discrimination properties of confocal microscopes to efficiently extract the near-field optical signal. Given their importance in a spectroscopic experiment, we systematically compare the lock-in and synchronous photon counting detection methods. Some results of Rayleigh's scattering in the near field of the test samples are used to illustrate the possibilities of this technique for reflection backscattering spectroscopy

  12. Near-field reflection backscattering apertureless optical microscopy: Application to spectroscopy experiments on opaque samples, comparison between lock-in and digital photon counting detection techniques

    Energy Technology Data Exchange (ETDEWEB)

    Diziain, S. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Bijeon, J.-L. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France)]. E-mail: bijeon@utt.fr; Adam, P.-M. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Lamy de la Chapelle, M. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Thomas, B. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Deturche, R. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Royer, P. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France)

    2007-01-15

    An apertureless scanning near-field optical microscope (ASNOM) in reflection backscattering configuration is designed to conduct spectroscopic experiments on opaque samples constituted of latex beads. The ASNOM proposed takes advantage of the depth-discrimination properties of confocal microscopes to efficiently extract the near-field optical signal. Given their importance in a spectroscopic experiment, we systematically compare the lock-in and synchronous photon counting detection methods. Some results of Rayleigh's scattering in the near field of the test samples are used to illustrate the possibilities of this technique for reflection backscattering spectroscopy.

  13. Optical Techniques for Millimeter-Wave Phased Array Communications Antennas

    National Research Council Canada - National Science Library

    Edge, Colin

    1998-01-01

    The scope of this program was to study the application of optical techniques to signal distribution and beamforming networks in phased array antennas for Army mobile tactical communications systems...

  14. Qualitative and quantitative changes in phospholipids and proteins investigated by spectroscopic techniques in animal depression model

    Science.gov (United States)

    Depciuch, J.; Sowa-Kucma, M.; Nowak, G.; Papp, M.; Gruca, P.; Misztak, P.; Parlinska-Wojtan, M.

    2017-04-01

    Depression becomes nowadays a high mortality civilization disease with one of the major causes being chronic stress. Raman, Fourier Transform Infra Red (FTIR) and Ultraviolet-Visible (UV-vis) spectroscopies were used to determine the changes in the quantity and structure of phospholipids and proteins in the blood serum of rats subjected to chronic mild stress, which is a common animal depression model. Moreover, the efficiency of the imipramine treatment was evaluated. It was found that chronic mild stress not only damages the structure of the phospholipids and proteins, but also decreases their level in the blood serum. A 5 weeks imipramine treatment did increase slightly the quantity of proteins, leaving the damaged phospholipids unchanged. Structural information from phospholipids and proteins was obtained by UV-vis spectroscopy combined with the second derivative of the FTIR spectra. Indeed, the structure of proteins in blood serum of stressed rats was normalized after imipramine therapy, while the impaired structure of phospholipids remained unaffected. These findings strongly suggest that the depression factor, which is chronic mild stress, may induce permanent (irreversible) damages into the phospholipid structure identified as shortened carbon chains. This study shows a possible new application of spectroscopic techniques in the diagnosis and therapy monitoring of depression.

  15. Integrated Analysis of the Wood Oil from Xanthocyparis vietnamensis Farjon & Hiep. by Chromatographic and Spectroscopic Techniques.

    Science.gov (United States)

    Bazzali, Ophélie; Thai, Tran Huy; Hoi, Tran Minh; Khang, Nguyen Sinh; Hien, Nguyen Thi; Casanova, Joseph; Bighelli, Ange; Tomi, Félix

    2016-06-27

    In order to get better knowledge about the volatiles produced by Xanthocyparis vietnamensis, a species recently discovered in Vietnam, its wood oil has been analyzed by a combination of chromatographic (GC, CC) and spectroscopic (GC-MS, (13)C-NMR) techniques. Forty components that accounted for 87.9% of the oil composition have been identified. The composition is dominated by nootkatene (20.7%), 11,12,13-tri-nor-eremophil-1(10)-en-7-one (17.2%), γ-eudesmol (5.1%), nootkatone (4.7%), valencene (3.5%) and 13-nor-eremophil-1(10)-en-11-one (2.6%). The structure of two new compounds-10-epi-nor-γ-eudesmen-11-one and 12-hydroxy-isodihydroagarofuran-has been elucidated, while 11,12,13-tri-nor-eremophil-1(10)-en-7-ol is reported as a natural product for the first time. The composition of X. vietnamensis wood oil varied drastically from those of leaf oils, dominated by hedycaryol (34.4%), phyllocladene (37.8%) or by pimara-6(14)-15-diene (19.4%).

  16. Integrated Analysis of the Wood Oil from Xanthocyparis vietnamensis Farjon & Hiep. by Chromatographic and Spectroscopic Techniques

    Directory of Open Access Journals (Sweden)

    Ophélie Bazzali

    2016-06-01

    Full Text Available In order to get better knowledge about the volatiles produced by Xanthocyparis vietnamensis, a species recently discovered in Vietnam, its wood oil has been analyzed by a combination of chromatographic (GC, CC and spectroscopic (GC-MS, 13C-NMR techniques. Forty components that accounted for 87.9% of the oil composition have been identified. The composition is dominated by nootkatene (20.7%, 11,12,13-tri-nor-eremophil-1(10-en-7-one (17.2%, γ-eudesmol (5.1%, nootkatone (4.7%, valencene (3.5% and 13-nor-eremophil-1(10-en-11-one (2.6%. The structure of two new compounds—10-epi-nor-γ-eudesmen-11-one and 12-hydroxy-isodihydroagarofuran—has been elucidated, while 11,12,13-tri-nor-eremophil-1(10-en-7-ol is reported as a natural product for the first time. The composition of X. vietnamensis wood oil varied drastically from those of leaf oils, dominated by hedycaryol (34.4%, phyllocladene (37.8% or by pimara-6(14-15-diene (19.4%.

  17. Applications of structural and spectroscopic techniques to the experimental and theoretical study of new luminescent materials

    International Nuclear Information System (INIS)

    Navarro Ahumada, Gustavo Adolfo

    2001-01-01

    using the x-ray diffraction, neutron diffraction and diffuse neutron scattering techniques, and Raman and electronic spectroscopic characterization. Results are presented for cubic systems with Cr 3+ (3d 3 ) and Mo 3+ (4d 3 ) ions, since these are privileged from a spectroscopic point of view and except for the hexacyano ion of Cr(III), the crystal Cs 2 NaScCl: MoCl 6 3- is an elpasolite type structure (C.Wood)

  18. Machine learning techniques in optical communication

    DEFF Research Database (Denmark)

    Zibar, Darko; Piels, Molly; Jones, Rasmus Thomas

    2016-01-01

    Machine learning techniques relevant for nonlinearity mitigation, carrier recovery, and nanoscale device characterization are reviewed and employed. Markov Chain Monte Carlo in combination with Bayesian filtering is employed within the nonlinear state-space framework and demonstrated for parameter...

  19. Machine learning techniques in optical communication

    DEFF Research Database (Denmark)

    Zibar, Darko; Piels, Molly; Jones, Rasmus Thomas

    2015-01-01

    Techniques from the machine learning community are reviewed and employed for laser characterization, signal detection in the presence of nonlinear phase noise, and nonlinearity mitigation. Bayesian filtering and expectation maximization are employed within nonlinear state-space framework...

  20. Instrumental analysis of bacterial cells using vibrational and emission Moessbauer spectroscopic techniques

    International Nuclear Information System (INIS)

    Kamnev, Alexander A.; Tugarova, Anna V.; Antonyuk, Lyudmila P.; Tarantilis, Petros A.; Kulikov, Leonid A.; Perfiliev, Yurii D.; Polissiou, Moschos G.; Gardiner, Philip H.E.

    2006-01-01

    In biosciences and biotechnology, the expanding application of physicochemical approaches using modern instrumental techniques is an efficient strategy to obtain valuable and often unique information at the molecular level. In this work, we applied a combination of vibrational (Fourier transform infrared (FTIR), FT-Raman) spectroscopic techniques, useful in overall structural and compositional analysis of bacterial cells of the rhizobacterium Azospirillum brasilense, with 57 Co emission Moessbauer spectroscopy (EMS) used for sensitive monitoring of metal binding and further transformations in live bacterial cells. The information obtained, together with ICP-MS analyses for metals taken up by the bacteria, is useful in analysing the impact of the environmental conditions (heavy metal stress) on the bacterial metabolism and some differences in the heavy metal stress-induced behaviour of non-endophytic (Sp7) and facultatively endophytic (Sp245) strains. The results show that, while both strains Sp7 and Sp245 take up noticeable and comparable amounts of heavy metals from the medium (0.12 and 0.13 mg Co, 0.48 and 0.44 mg Cu or 4.2 and 2.1 mg Zn per gram of dry biomass, respectively, at a metal concentration of 0.2 mM in the medium), their metabolic responses differ essentially. Whereas for strain Sp7 the FTIR measurements showed significant accumulation of polyhydroxyalkanoates as storage materials involved in stress endurance, strain Sp245 did not show any major changes in cellular composition. Nevertheless, EMS measurements showed rapid binding of cobalt(II) by live bacterial cells (chemically similar to metal binding by dead bacteria) and its further transformation in the live cells within an hour

  1. Instrumental analysis of bacterial cells using vibrational and emission Moessbauer spectroscopic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kamnev, Alexander A. [Laboratory of Biochemistry of Plant-Bacterial Symbioses, Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov (Russian Federation)]. E-mail: aakamnev@ibppm.sgu.ru; Tugarova, Anna V. [Laboratory of Biochemistry of Plant-Bacterial Symbioses, Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov (Russian Federation); Antonyuk, Lyudmila P. [Laboratory of Biochemistry of Plant-Bacterial Symbioses, Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov (Russian Federation); Tarantilis, Petros A. [Laboratory of Chemistry, Department of Science, Agricultural University of Athens, 11855 Athens (Greece); Kulikov, Leonid A. [Laboratory of Nuclear Chemistry Techniques, Department of Radiochemistry, Faculty of Chemistry, M.V. Lomonosov Moscow State University, 119992 Moscow (Russian Federation); Perfiliev, Yurii D. [Laboratory of Nuclear Chemistry Techniques, Department of Radiochemistry, Faculty of Chemistry, M.V. Lomonosov Moscow State University, 119992 Moscow (Russian Federation); Polissiou, Moschos G. [Laboratory of Chemistry, Department of Science, Agricultural University of Athens, 11855 Athens (Greece); Gardiner, Philip H.E. [Division of Chemistry, School of Science and Mathematics, Sheffield Hallam University, Sheffield S1 1WB (United Kingdom)

    2006-07-28

    In biosciences and biotechnology, the expanding application of physicochemical approaches using modern instrumental techniques is an efficient strategy to obtain valuable and often unique information at the molecular level. In this work, we applied a combination of vibrational (Fourier transform infrared (FTIR), FT-Raman) spectroscopic techniques, useful in overall structural and compositional analysis of bacterial cells of the rhizobacterium Azospirillum brasilense, with {sup 57}Co emission Moessbauer spectroscopy (EMS) used for sensitive monitoring of metal binding and further transformations in live bacterial cells. The information obtained, together with ICP-MS analyses for metals taken up by the bacteria, is useful in analysing the impact of the environmental conditions (heavy metal stress) on the bacterial metabolism and some differences in the heavy metal stress-induced behaviour of non-endophytic (Sp7) and facultatively endophytic (Sp245) strains. The results show that, while both strains Sp7 and Sp245 take up noticeable and comparable amounts of heavy metals from the medium (0.12 and 0.13 mg Co, 0.48 and 0.44 mg Cu or 4.2 and 2.1 mg Zn per gram of dry biomass, respectively, at a metal concentration of 0.2 mM in the medium), their metabolic responses differ essentially. Whereas for strain Sp7 the FTIR measurements showed significant accumulation of polyhydroxyalkanoates as storage materials involved in stress endurance, strain Sp245 did not show any major changes in cellular composition. Nevertheless, EMS measurements showed rapid binding of cobalt(II) by live bacterial cells (chemically similar to metal binding by dead bacteria) and its further transformation in the live cells within an hour.

  2. Optical constants of CH3NH3PbBr3 perovskite thin films measured by spectroscopic ellipsometry

    KAUST Repository

    Alias, Mohd Sharizal

    2016-07-14

    The lack of optical constants information for hybrid perovskite of CH3NH3PbBr3 in thin films form can delay the progress of efficient LED or laser demonstration. Here, we report on the optical constants (complex refractive index and dielectric function) of CH3NH3PbBr3 perovskite thin films using spectroscopic ellipsometry. Due to the existence of voids, the refractive index of the thin films is around 8% less than the single crystals counterpart. The energy bandgap is around 2.309 eV as obtained from photoluminescence and spectrophotometry spectra, and calculated from the SE analysis. The precise measurement of optical constants will be useful in designing optical devices using CH3NH3PbBr3 thin films.

  3. Quasi-optical techniques for ECRH

    International Nuclear Information System (INIS)

    Andenaerde, K.; Beyer, J.; Vernon, R.

    1985-01-01

    The status of research at Wisconsin on quasi-optical launchers for ECRH is presented. Wengenroth's mode transducing antenna has been investigated theoretically. Agreement with experiment using TE 01 excitation is excellent, and the theory has been expanded to include TE 02 and TE 03 excitation as well. A system incorporating such and similar mode transducing antennas with a Cassegrain system will combine the output of various gyrotrons. A device to test this and similar concepts is being built and has been preliminarily tested for mode purity

  4. A digital transducer and digital microphone using an optical technique

    Science.gov (United States)

    Ghelmansarai, F. A.

    1996-09-01

    A transducer is devised to measure pressure, displacements or angles by optical means. This transducer delivers a digital output without relying on interferometry techniques or analogue-to-digital converters. This device is based on an optical scanner and an optical detector. An inter-digital photoconductive detector (IDPC) is employed that delivers a series of pulses, whose number depends on the scan length. A pre-objective scanning configuration is used that allows for the possibility of a flat image plane. The optical scanner provides scanning of IDPC and the generated scan length is proportional to the measurand.

  5. Growth and spectroscopic, thermodynamic and nonlinear optical studies of L-threonine phthalate crystal

    Science.gov (United States)

    Theras, J. Elberin Mary; Kalaivani, D.; Jayaraman, D.; Joseph, V.

    2015-10-01

    L-threonine phthalate (LTP) single crystal has been grown using a solution growth technique at room temperature. Single crystal X-ray diffraction analysis reveals that LTP crystallizes in monoclinic crystal system with space group C2/c. The optical absorption studies show that the crystal is transparent in the entire visible region with a cut-off wavelength 309 nm. The optical band gap is found to be 4.05 eV. The functional groups of the synthesized compound have been identified by FTIR spectral analysis. The functional groups present in the material were also confirmed by FT-RAMAN spectroscopy. Surface morphology and the presence of various elements were studied by SEM-EDAX analysis. The thermal stability of LTP single crystal has been analyzed by TGA/DTA studies. The thermodynamic parameters such as activation energy, entropy, enthalpy and Gibbs free energy were determined for the grown material using TG data and Coats-Redfern relation. Since the grown crystal is centrosymmetric, Z-Scan studies were carried out for analyzing the third order nonlinear optical property. The nonlinear absorption coefficient, nonlinear refractive index and susceptibility have been measured using Z-Scan technique.

  6. Tear film measurement by optical reflectometry technique

    Science.gov (United States)

    Lu, Hui; Wang, Michael R.; Wang, Jianhua; Shen, Meixiao

    2014-01-01

    Abstract. Evaluation of tear film is performed by an optical reflectometer system with alignment guided by a galvanometer scanner. The reflectometer system utilizes optical fibers to deliver illumination light to the tear film and collect the film reflectance as a function of wavelength. Film thickness is determined by best fitting the reflectance-wavelength curve. The spectral reflectance acquisition time is 15 ms, fast enough for detecting film thickness changes. Fast beam alignment of 1 s is achieved by the galvanometer scanner. The reflectometer was first used to evaluate artificial tear film on a model eye with and without a contact lens. The film thickness and thinning rate have been successfully quantified with the minimum measured thickness of about 0.3 μm. Tear films in human eyes, with and without a contact lens, have also been evaluated. A high-contrast spectral reflectance signal from the precontact lens tear film is clearly observed, and the thinning dynamics have been easily recorded from 3.69 to 1.31 μm with lipid layer thickness variation in the range of 41 to 67 nm. The accuracy of the measurement is better than ±0.58% of the film thickness at an estimated tear film refractive index error of ±0.001. The fiber-based reflectometer system is compact and easy to handle. PMID:24500519

  7. Coupling spectroscopic and chromatographic techniques for evaluation of the depositional history of hydrocarbons in a subtropical estuary

    International Nuclear Information System (INIS)

    Martins, César C.; Doumer, Marta E.; Gallice, Wellington C.; Dauner, Ana Lúcia L.; Cabral, Ana Caroline; Cardoso, Fernanda D.

    2015-01-01

    Spectroscopic and chromatographic techniques can be used together to evaluate hydrocarbon inputs to coastal environments such as the Paranaguá estuarine system (PES), located in the SW Atlantic, Brazil. Historical inputs of aliphatic hydrocarbons (AHs) and polycyclic aromatic hydrocarbons (PAHs) were analyzed using two sediment cores from the PES. The AHs were related to the presence of biogenic organic matter and degraded oil residues. The PAHs were associated with mixed sources. The highest hydrocarbon concentrations were related to oil spills, while relatively low levels could be attributed to the decrease in oil usage during the global oil crisis. The results of electron paramagnetic resonance were in agreement with the absolute AHs and PAHs concentrations measured by chromatographic techniques, while near-infrared spectroscopy results were consistent with unresolved complex mixture (UCM)/total n-alkanes ratios. These findings suggest that the use of a combination of techniques can increase the accuracy of assessment of contamination in sediments. - Highlights: • Historical inputs of hydrocarbons in a subtropical estuary were evaluated. • Spectroscopic and chromatographic methods were used in combination. • High hydrocarbon concentrations were related to anthropogenic activities. • Low hydrocarbon levels could be explained by the 1970s global oil crisis. - Spectroscopic and chromatographic techniques could be used together to evaluate hydrocarbon inputs to coastal environments

  8. NARROW-LINE X-RAY-SELECTED GALAXIES IN THE CHANDRA -COSMOS FIELD. I. OPTICAL SPECTROSCOPIC CATALOG

    Energy Technology Data Exchange (ETDEWEB)

    Pons, E.; Watson, M. G. [University of Leicester, Leicester (United Kingdom); Elvis, M.; Civano, F. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA (United States)

    2016-04-20

    The COSMOS survey is a large and deep survey with multiwavelength observations of sources from X-rays to the UV, allowing an extensive study of their properties. The central 0.9 deg{sup 2} of the COSMOS field have been observed by Chandra with a sensitivity up to 1.9 × 10{sup −16} erg cm{sup −2} s{sup −1} in the full (0.5–10 keV) band. Photometric and spectroscopic identification of the Chandra -COSMOS (C-COSMOS) sources is available from several catalogs and campaigns. Despite the fact that the C-COSMOS galaxies have a reliable spectroscopic redshift in addition to a spectroscopic classification, the emission-line properties of this sample have not yet been measured. We present here the creation of an emission-line catalog of 453 narrow-line sources from the C-COSMOS spectroscopic sample. We have performed spectral fitting for the more common lines in galaxies ([O ii] λ 3727, [Ne iii] λ 3869, H β , [O iii] λλ 4959, 5007, H α , and [N ii] λλ 6548, 6584). These data provide an optical classification for 151 (i.e., 33%) of the C-COSMOS narrow-line galaxies based on emission-line diagnostic diagrams.

  9. Synthesis and spectroscopic characterization of gold nanoparticles via plasma-liquid interaction technique

    Science.gov (United States)

    Khatoon, N.; Yasin, H. M.; Younus, M.; Ahmed, W.; Rehman, N. U.; Zakaullah, M.; Iqbal, M. Zafar

    2018-01-01

    Fabrication of non-functionalized gold nanoparticles is interesting owing to their potential applications in sensing and biomedicine. We report on the synthesis of surfactant-free gold nanoparticles (AuNPs) by Plasma-Liquid Interaction (PLI) technique, using micro-atmospheric pressure D.C. plasma. The effects of discharge parameters, such as discharge current, precursor concentration and gas flow rates on the structure and morphology of AuNPs have been investigated. Optical Emission Spectroscopy (OES) was employed to estimate the UV radiation intensity and OH radical density. Scanning electron microscopy (SEM) and ultraviolet-visible (UV-Vis) optical spectroscopy were employed to study the morphology and structure of AuNPs. The normalized intensities of UV radiation and OH radical density found to increase with increase in discharge current. We observed that the particle size can be tuned by controlling any of the following parameters: intensity of the UV radiation, OH radical density, and concentration of the Au precursor. Interestingly, we found that addition of 1% Ar in the feedstock gas results in formation of relatively uniform size distribution of nanoparticles. The surfactant-free AuNPs, due to their bare-surface, exhibit excellent surface-enhanced Raman scattering (SERS) properties. The SERS study of Rhodamine 6G using AuNPs as substrates, shows significant Raman enhancement and fluorescence quenching, which makes our technique a potentially powerful route to detection of trace amounts of dangerous explosives and other materials.

  10. Nano-particle doped hydroxyapatite material evaluation using spectroscopic polarization sensitive optical coherence tomography

    Science.gov (United States)

    Strąkowska, Paulina; Trojanowski, Michał; Gardas, Mateusz; Głowacki, Maciej J.; Kraszewski, Maciej; Strąkowski, Marcin R.

    2015-03-01

    Bio-ceramics such as hydroxyapatite (HAp) are widely used materials in medical applications, especially as an interface between implants and living tissues. There are many ways of creating structures from HAp like electrochemical assisted deposition, biomimetic, electrophoresis, pulsed laser deposition or sol-gel processing. Our research is based on analyzing the parameters of the sol-gel method for creating thin layers of HAp. In order to achieve this, we propose to use Optical Coherence Tomography (OCT) for non-destructive and non-invasive evaluation. Our system works in the IR spectrum range, which is helpful due to the wide range of nanocomposites being opaque in the VIS range. In order to use our method we need to measure two samples, one which is a reference HAp solution and second: a similar HAp solution with nanoparticles introduced inside. We use silver nanoparticles below 300 nm. The aim of this research is to analyze the concentration and dispersion of nanodopants in the bio-ceramic matrix. Furthermore, the quality of the HAp coating and deposition process repetition have been monitored. For this purpose the polarization sensitive OCT with additional spectroscopic analysis is being investigated. Despite the other methods, which are suitable for nanocomposite materials evaluation, the OCT with additional features seems to be one of the few which belong to the NDE/NDT group. Here we are presenting the OCT system for evaluation of the HAp with nano-particles, as well as HAp manufacturing process. A brief discussion on the usefulness of OCT for bio-ceramics materials examination is also being presented.

  11. Field results of antifouling techniques for optical instruments

    Science.gov (United States)

    Strahle, W.J.; Hotchkiss, F.S.; Martini, Marinna A.

    1998-01-01

    An anti-fouling technique is developed for the protection of optical instruments from biofouling which leaches a bromide compound into a sample chamber and pumps new water into the chamber prior to measurement. The primary advantage of using bromide is that it is less toxic than the metal-based antifoulants. The drawback of the bromide technique is also discussed.

  12. Dual-window dual-bandwidth spectroscopic optical coherence tomography metric for qualitative scatterer size differentiation in tissues.

    Science.gov (United States)

    Tay, Benjamin Chia-Meng; Chow, Tzu-Hao; Ng, Beng-Koon; Loh, Thomas Kwok-Seng

    2012-09-01

    This study investigates the autocorrelation bandwidths of dual-window (DW) optical coherence tomography (OCT) k-space scattering profile of different-sized microspheres and their correlation to scatterer size. A dual-bandwidth spectroscopic metric defined as the ratio of the 10% to 90% autocorrelation bandwidths is found to change monotonically with microsphere size and gives the best contrast enhancement for scatterer size differentiation in the resulting spectroscopic image. A simulation model supports the experimental results and revealed a tradeoff between the smallest detectable scatterer size and the maximum scatterer size in the linear range of the dual-window dual-bandwidth (DWDB) metric, which depends on the choice of the light source optical bandwidth. Spectroscopic OCT (SOCT) images of microspheres and tonsil tissue samples based on the proposed DWDB metric showed clear differentiation between different-sized scatterers as compared to those derived from conventional short-time Fourier transform metrics. The DWDB metric significantly improves the contrast in SOCT imaging and can aid the visualization and identification of dissimilar scatterer size in a sample. Potential applications include the early detection of cell nuclear changes in tissue carcinogenesis, the monitoring of healing tendons, and cell proliferation in tissue scaffolds.

  13. Thermodynamics and binding mechanism of polyphenon-60 with human lysozyme elucidated by calorimetric and spectroscopic techniques

    International Nuclear Information System (INIS)

    Yasmeen, Shama; Riyazuddeen

    2017-01-01

    Highlights: • Thermodynamics of the binding of Lys with polypenone-60 were studied. • The binding was found to be exothermic. • Polyphenon-60 quenches the fluorescence of Lys through static quenching. • Polyphenon-60 binds to Lys through hydrogen binding. • Conformational changes of Lys were studied using circular dichorism. - Abstract: Protein-drug interaction offer information of the structural features that determine the therapeutic effectiveness of drug and have become an attractive research field in life science, chemistry, and clinical medicine. Interaction of pharmacologically important antioxidant drug polyphenon-60 with human lysozyme (Lys) at physiological pH 7.4 has been studied by using calorimetric and various spectroscopic techniques. UV–visible spectroscopy results indicate the complex formation between Lys and polyphenon-60. The binding constant, quenching mechanism and the number of binding sites were determined by the fluorescence quenching spectra of Lys in presence of polyphenon-60. Fluorescence data indicate that the polyphenon-60 interact with Lys through static quenching mechanism with binding affinity of 2.9 × 10 4 M −1 . The average binding distance between drug and Lys was found to be 2.89 nm on the basis of the theory of Förster's energy transfer. Isothermal titration calorimetry (ITC) data reveals the thermodynamic investigations which suggest that the interaction of Lys and polyphenon-60 through exothermic process and enthalpy driven and also explore that the polyphenon-60 binds in both sites of Lys with high and low affinity. Hydrogen bonding (high affinity) and hydrophobic interactions (low affinity) are the major forces in stabilizing the drug protein complex. Far-UV CD and FTIR results deciphere the conformational alterations in the secondary structure of Lys.

  14. Optical spectroscopic methods for probing the conformational stability of immobilised enzymes.

    Science.gov (United States)

    Ganesan, Ashok; Moore, Barry D; Kelly, Sharon M; Price, Nicholas C; Rolinski, Olaf J; Birch, David J S; Dunkin, Ian R; Halling, Peter J

    2009-07-13

    We report the development of biophysical techniques based on circular dichroism (CD), diffuse reflectance infrared Fourier transform (DRIFT) and tryptophan (Trp) fluorescence to investigate in situ the structure of enzymes immobilised on solid particles. Their applicability is demonstrated using subtilisin Carlsberg (SC) immobilised on silica gel and Candida antartica lipase B immobilised on Lewatit VP.OC 1600 (Novozyme 435). SC shows nearly identical secondary structure in solution and in the immobilised state as evident from far UV CD spectra and amide I vibration bands. Increased near UV CD intensity and reduced Trp fluorescence suggest a more rigid tertiary structure on the silica surface. After immobilised SC is inactivated, these techniques reveal: a) almost complete loss of near UV CD signal, suggesting loss of tertiary structure; b) a shift in the amide I vibrational band from 1658 cm(-1) to 1632 cm(-1), indicating a shift from alpha-helical structure to beta-sheet; c) a substantial blue shift and reduced dichroism in the far UV CD, supporting a shift to beta-sheet structure; d) strong increase in Trp fluorescence intensity, which reflects reduced intramolecular quenching with loss of tertiary structure; and e) major change in fluorescence lifetime distribution, confirming a substantial change in Trp environment. DRIFT measurements suggest that pressing KBr discs may perturb protein structure. With the enzyme on organic polymer it was possible to obtain near UV CD spectra free of interference by the carrier material. However, far UV CD, DRIFT and fluorescence measurements showed strong signals from the organic support. In conclusion, the spectroscopic methods described here provide structural information hitherto inaccessible, with their applicability limited by interference from, rather than the particulate nature of, the support material.

  15. MSE spectrograph optical design: a novel pupil slicing technique

    Science.gov (United States)

    Spanò, P.

    2014-07-01

    The Maunakea Spectroscopic Explorer shall be mainly devoted to perform deep, wide-field, spectroscopic surveys at spectral resolutions from ~2000 to ~20000, at visible and near-infrared wavelengths. Simultaneous spectral coverage at low resolution is required, while at high resolution only selected windows can be covered. Moreover, very high multiplexing (3200 objects) must be obtained at low resolution. At higher resolutions a decreased number of objects (~800) can be observed. To meet such high demanding requirements, a fiber-fed multi-object spectrograph concept has been designed by pupil-slicing the collimated beam, followed by multiple dispersive and camera optics. Different resolution modes are obtained by introducing anamorphic lenslets in front of the fiber arrays. The spectrograph is able to switch between three resolution modes (2000, 6500, 20000) by removing the anamorphic lenses and exchanging gratings. Camera lenses are fixed in place to increase stability. To enhance throughput, VPH first-order gratings has been preferred over echelle gratings. Moreover, throughput is kept high over all wavelength ranges by splitting light into more arms by dichroic beamsplitters and optimizing efficiency for each channel by proper selection of glass materials, coatings, and grating parameters.

  16. Liquidus temperature and optical properties measurement by containerless techniques

    Science.gov (United States)

    Anderson, Collin D.

    1993-01-01

    Reactive alloy liquidus temperatures measured by conventional, contained techniques are often in error due to reactions with containers and gaseous impurities. This paper describes a new liquidus temperature measurement technique that avoids these problems by employing containerless processing. This technique relies on precise and accurate noncontact temperature measurements (NCTM), which are made possible by spectral emissivity values. The spectral emissivities, epsilon(sub lambda), are measured along with the optical properties (real, n, and imaginary, k, components of the index of refraction) using polarimetric techniques on electromagnetically levitated specimens. Results from work done at Vanderbilt University and Intersonics on the Ti-Al system are presented to demonstrate the above techniques.

  17. Optical properties of LiGaS{sub 2}: an ab initio study and spectroscopic ellipsometry measurement

    Energy Technology Data Exchange (ETDEWEB)

    Atuchin, V V [Laboratory of Optical Materials and Structures, Institute of Semiconductor Physics, SB RAS, Novosibirsk 90, 630090 (Russian Federation); Lin, Z S [Beijing Center for Crystal R and D, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, PO Box 2711, Beijing 100190 (China); Isaenko, L I; Lobanov, S I [Laboratory of Crystal Growth, Institute of Geology and Mineralogy, SB RAS, Novosibirsk 90, 630090 (Russian Federation); Kesler, V G [Laboratory of Physical Bases of Integrated Microelectronics, Institute of Semiconductor Physics, SB RAS, Novosibirsk 90, 630090 (Russian Federation); Kruchinin, V N, E-mail: zslin@mail.ipc.ac.c [Laboratory for Ellipsometry of Semiconductor Materials and Structures, Institute of Semiconductor Physics, SB RAS, Novosibirsk 90, 630090 (Russian Federation)

    2009-11-11

    Electronic and optical properties of lithium thiogallate crystal, LiGaS{sub 2}, have been investigated by both experimental and theoretical methods. The plane-wave pseudopotential method based on DFT theory has been used for band structure calculations. The electronic parameters of Ga 3d orbitals have been corrected by the DFT+U methods to be consistent with those measured with x-ray photoemission spectroscopy. Evolution of optical constants of LiGaS{sub 2} over a wide spectral range was determined by developed first-principles theory and dispersion curves were compared with optical parameters defined by spectroscopic ellipsometry in the photon energy range 1.2-5.0 eV. Good agreement has been achieved between theoretical and experimental results.

  18. Investigating Functional Extension of Optical Coherence Tomography for Spectroscopic Analysis of Blood Oxygen Saturation

    Science.gov (United States)

    Chen, Siyu

    Over the past two decades, optical coherence tomography (OCT) has been successfully applied to various fields of biomedical researching and clinical studies, including cardiology, urology, dermatology, dentistry, oncology, and most successfully, ophthalmology. This dissertation seeks to extend the current OCT practice, which is still largely morphology-based, into a new dimension, functional analysis of metabolic activities in vivo. More specifically, the investigation is focused on retrieving blood oxygen saturation (sO2) using intrinsic hemoglobin optical absorption contrast. Most mammalian cells rely on aerobic respiration to support cellular function, which means they consume oxygen to create adenosine triphosphate (ATP). Metabolic rate of oxygen (MRO2), a key hemodynamic parameter, characterizes how much oxygen is consumed during a given period of time, reflecting the metabolic activity of the target tissue. For example, retinal neurons are highly active and almost entirely rely on the moment-to-moment oxygen supply from retinal circulations. Thus, variation in MRO2 reveals the instantaneous activity of these neurons, shedding light on the physiological and pathophysiological change of cellular functions. Eventually, measuring MRO2 can potentially provide a biomarker for early-stage disease diagnosis, and serve as one benchmark for evaluating effectiveness of medical intervention during disease management. Essential in calculating MRO2, blood sO2 measurements using spectroscopic OCT analysis has been attempted as early as 2003. OCT is intrinsically sensitive to the blood optical absorption spectrum due to its wide-band illumination and detection scheme relying on back-scattered photon. However, accurate retrieval of blood sO2 using conventional near infrared (NIR) OCT systems in vivo has remained challenging. It was not until the development of OCT systems using visible light illumination (vis-OCT) when accurate measurement of blood sO2 was reported in live

  19. Techniques for removing contaminants from optical surfaces

    International Nuclear Information System (INIS)

    Stowers, I.F.; Patton, H.G.

    1978-01-01

    Particle removal procedures such as plasma cleaning, ultrasonic agitation of solvents, detergents, solvent wiping, mild abrasives, vapor degreasing, high pressure solvent spraying and others have been evaluated and the results are reported here. Wiping with a lens tissue wetted with an organic solvent and high pressure fluid spraying are the only methods by which particles as small as 5 μm can be effectively removed. All of the other methods tested were found to be at least two orders of magnitude less effective at removing small insoluble particles. An additional and as yet unresolved problem is the development of a reliable method for evaluating particulate surface cleanliness. Without such a reproducible monitoring technique, the large diversity of cleaning methods currently available cannot be quantitatively evaluated

  20. Glycation and secondary conformational changes of human serum albumin: study of the FTIR spectroscopic curve-fitting technique

    Directory of Open Access Journals (Sweden)

    Yu-Ting Huang

    2016-05-01

    Full Text Available The aim of this study was attempted to investigate both the glycation kinetics and protein secondary conformational changes of human serum albumin (HSA after the reaction with ribose. The browning and fluorescence determinations as well as Fourier transform infrared (FTIR microspectroscopy with a curve-fitting technique were applied. Various concentrations of ribose were incubated over a 12-week period at 37 ± 0.5 oC under dark conditions. The results clearly shows that the glycation occurred in HSA-ribose reaction mixtures was markedly increased with the amount of ribose used and incubation time, leading to marked alterations of protein conformation of HSA after FTIR determination. In addition, the browning intensity of reaction solutions were colored from light to deep brown, as determined by optical observation. The increase in fluorescence intensity from HSA–ribose mixtures seemed to occur more quickly than browning, suggesting that the fluorescence products were produced earlier on in the process than compounds causing browning. Moreover, the predominant α-helical composition of HSA decreased with an increase in ribose concentration and incubation time, whereas total β-structure and random coil composition increased, as determined by curve-fitted FTIR microspectroscopy analysis. We also found that the peak intensity ratios at 1044 cm−1/1542 cm−1 markedly decreased prior to 4 weeks of incubation, then almost plateaued, implying that the consumption of ribose in the glycation reaction might have been accelerated over the first 4 weeks of incubation, and gradually decreased. This study first evidences that two unique IR peaks at 1710 cm−1 [carbonyl groups of irreversible products produced by the reaction and deposition of advanced glycation end products (AGEs] and 1621 cm−1 (aggregated HSA molecules were clearly observed from the curve-fitted FTIR spectra of HSA-ribose mixtures over the course of incubation time. This study

  1. A comparative analysis of five chrome green pigments based on different spectroscopic techniques

    International Nuclear Information System (INIS)

    Desnica, V.; Furic, K.; Hochleitner, B.; Mantler, M.

    2003-01-01

    A detailed study of five chrome-based green pigments belonging to a large pigment collection at the Academy of Fine Arts in Vienna, Austria has been performed. The samples were analyzed and compared using the two X-ray methods--X-ray fluorescence and X-ray diffraction, and the two optical methods--Raman spectroscopy and infrared spectroscopy. The composition differences between the similarly denoted samples of the collection were determined and the significant sensitivity differences of the investigated methods to specific compounds have been established. This relative discrepancy of the obtained results depending on the technique used proved once again the need of a combined use of the investigated methods

  2. M-line spectroscopic, spectroscopic ellipsometric and microscopic measurements of optical waveguides fabricated by MeV-energy N{sup +} ion irradiation for telecom applications

    Energy Technology Data Exchange (ETDEWEB)

    Bányász, I., E-mail: banyasz@sunserv.kfki.hu [Wigner Research Centre for Physics, Hungarian Academy of Sciences, P.O.B. 49, H-1525, Budapest (Hungary); Berneschi, S. [“Enrico Fermi” Center for Study and Research, Piazza del Viminale 2, 00184 Roma (Italy); MDF-Lab, “Nello Carrara” Institute of Applied Physics, IFAC-CNR, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Fried, M.; Lohner, T. [Institute of Technical Physics and Materials Science, Research Centre for Natural Sciences, Hungarian Academy of Sciences, P.O.B. 49, H-1525, Budapest (Hungary); Conti, G. Nunzi; Righini, G.C.; Pelli, S. [MDF-Lab, “Nello Carrara” Institute of Applied Physics, IFAC-CNR, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Zolnai, Z. [Institute of Technical Physics and Materials Science, Research Centre for Natural Sciences, Hungarian Academy of Sciences, P.O.B. 49, H-1525, Budapest (Hungary)

    2013-08-31

    Irradiation with N{sup +} ions of the 1.5–3.5 MeV energy range was applied to optical waveguide formation. Planar and channel waveguides have been fabricated in an Er-doped tungsten–tellurite glass, and in both types of bismuth germanate (BGO) crystals: Bi{sub 4}Ge{sub 3}O{sub 12} (eulytine) and Bi{sub 12}GeO{sub 20} (sillenite). Multi-wavelength m-line spectroscopy and spectroscopic ellipsometry were used for the characterisation of the ion beam irradiated waveguides. Planar waveguides fabricated in the Er-doped tungsten–tellurite glass using irradiation with N{sup +} ions at 3.5 MeV worked even at the 1550 nm telecommunication wavelength. 3.5 MeV N{sup +} ion irradiated planar waveguides in eulytine-type BGO worked up to 1550 nm and those in sillenite-type BGO worked up to 1330 nm. - Highlights: ► Waveguides were fabricated in glass and crystals using MeV energy N{sup +} ions. ► SRIM simulation and spectroscopic ellipsometry yielded similar waveguide structures. ► Multi-wavelength m-line spectroscopy was used to study the waveguides. ► Waveguides fabricated in an Er-doped tungsten–tellurite glass worked up to 1.5 μm. ► Waveguides in Bi{sub 12}GeO{sub 20} remained operative up to 1.5 μm.

  3. ADVANCED OPTICAL TECHNIQUES TO EXPLORE BRAIN STRUCTURE AND FUNCTION

    OpenAIRE

    Silvestri, L.; Mascaro, A. L. Allegra; Lotti, J.; Sacconi, L.; Pavone, F. S.

    2013-01-01

    Understanding brain structure and function, and the complex relationships between them, is one of the grand challenges of contemporary sciences. Thanks to their flexibility, optical techniques could be the key to explore this complex network. In this manuscript, we briefly review recent advancements in optical methods applied to three main issues: anatomy, plasticity and functionality. We describe novel implementations of light-sheet microscopy to resolve neuronal anatomy in whole fixed brain...

  4. Probing of O2 vacancy defects and correlated magnetic, electrical and photoresponse properties in indium-tin oxide nanostructures by spectroscopic techniques

    Science.gov (United States)

    Ghosh, Shyamsundar; Dev, Bhupendra Nath

    2018-05-01

    Indium-tin oxide (ITO) 1D nanostructures with tunable morphologies i.e. nanorods, nanocombs and nanowires are grown on c-axis (0 0 0 1) sapphire (Al2O3) substrate in oxygen deficient atmosphere through pulsed laser deposition (PLD) technique and the effect of oxygen vacancies on optical, electrical, magnetic and photoresponse properties is investigated using spectroscopic methods. ITO nanostructures are found to be enriched with significant oxygen vacancy defects as evident from X-ray photoelectron and Raman spectroscopic analysis. Photoluminescence spectra exhibited intense mid-band blue emission at wavelength of region of 400-450 nm due to the electronic transition from conduction band maxima (CBM) to the singly ionized oxygen-vacancy (VO+) defect level within the band-gap. Interestingly, ITO nanostructures exhibited significant room-temperature ferromagnetism (RTFM) and the magnetic moment found proportional to concentration of VO+ defects which indicates VO+ defects are mainly responsible for the observed RTFM in nanostructures. ITO nanowires being enriched with more VO+ defects exhibited strongest RTFM as compared to other morphologies. Current voltage (I-V) characteristics of ITO nanostructures showed an enhancement of current under UV light as compared to dark which indicates such 1D nanostructure can be used as photovoltaic material. Hence, the study shows that there is ample opportunity to tailor the properties of ITOs through proper defect engineering's and such photosensitive ferromagnetic semiconductors might be promising for spintronic and photovoltaic applications.

  5. Imaging, scattering, and spectroscopic systems for biomedical optics: Tools for bench top and clinical applications

    Science.gov (United States)

    Cottrell, William J.

    Optical advances have had a profound impact on biology and medicine. The capabilities range from sensing biological analytes to whole animal and subcellular imaging and clinical therapies. The work presented in this thesis describes three independent and multifunctional optical systems, which explore clinical therapy at the tissue level, biological structure at the cell/organelle level, and the function of underlying fundamental cellular processes. First, we present a portable clinical instrument for delivering delta-aminolevulinic acid photodynamic therapy (ALA-PDT) while performing noninvasive spectroscopic monitoring in vivo. Using an off-surface probe, the instrument delivered the treatment beam to a user-defined field on the skin and performed reflectance and fluorescence spectroscopies at two regions within this field. The instrument was used to monitor photosensitizer fluorescence photobleaching, fluorescent photoproduct kinetics, and blood oxygen saturation during a clinical ALA-PDT trial on superficial basal cell carcinoma (sBCC). Protoporphyrin IX and photoproduct fluorescence excited by the 632.8 nm PDT treatment laser was collected between 665 and 775 nm. During a series of brief treatment interruptions at programmable time points, white-light reflectance spectra between 475 and 775 nm were acquired. Fluorescence spectra were corrected for the effects of absorption and scattering, informed by the reflectance measurements, and then decomposed into known fluorophore contributions in real time using a robust singular-value decomposition fitting routine. Reflectance spectra additionally provided information on hemoglobin oxygen saturation. We next describe the incorporation of this instrument into clinical trials at Roswell Park Cancer Institute (Buffalo, NY). In this trial we examined the effects of light irradiance on photodynamic efficiency and pain. The rate of singlet-oxygen production depends on the product of irradiance and photosensitizer and oxygen

  6. Congestion estimation technique in the optical network unit registration process.

    Science.gov (United States)

    Kim, Geunyong; Yoo, Hark; Lee, Dongsoo; Kim, Youngsun; Lim, Hyuk

    2016-07-01

    We present a congestion estimation technique (CET) to estimate the optical network unit (ONU) registration success ratio for the ONU registration process in passive optical networks. An optical line terminal (OLT) estimates the number of collided ONUs via the proposed scheme during the serial number state. The OLT can obtain congestion level among ONUs to be registered such that this information may be exploited to change the size of a quiet window to decrease the collision probability. We verified the efficiency of the proposed method through simulation and experimental results.

  7. Optical frequency upconversion technique for transmission of wireless MIMO-type signals over optical fiber.

    Science.gov (United States)

    Shaddad, R Q; Mohammad, A B; Al-Gailani, S A; Al-Hetar, A M

    2014-01-01

    The optical fiber is well adapted to pass multiple wireless signals having different carrier frequencies by using radio-over-fiber (ROF) technique. However, multiple wireless signals which have the same carrier frequency cannot propagate over a single optical fiber, such as wireless multi-input multi-output (MIMO) signals feeding multiple antennas in the fiber wireless (FiWi) system. A novel optical frequency upconversion (OFU) technique is proposed to solve this problem. In this paper, the novel OFU approach is used to transmit three wireless MIMO signals over a 20 km standard single mode fiber (SMF). The OFU technique exploits one optical source to produce multiple wavelengths by delivering it to a LiNbO3 external optical modulator. The wireless MIMO signals are then modulated by LiNbO3 optical intensity modulators separately using the generated optical carriers from the OFU process. These modulators use the optical single-sideband with carrier (OSSB+C) modulation scheme to optimize the system performance against the fiber dispersion effect. Each wireless MIMO signal is with a 2.4 GHz or 5 GHz carrier frequency, 1 Gb/s data rate, and 16-quadrature amplitude modulation (QAM). The crosstalk between the wireless MIMO signals is highly suppressed, since each wireless MIMO signal is carried on a specific optical wavelength.

  8. OPTICAL SPECTROSCOPIC OBSERVATIONS OF GAMMA-RAY BLAZAR CANDIDATES. VI. FURTHER OBSERVATIONS FROM TNG, WHT, OAN, SOAR, AND MAGELLAN TELESCOPES

    Energy Technology Data Exchange (ETDEWEB)

    Álvarez Crespo, N.; Massaro, F. [Dipartimento di Fisica, Università degli Studi di Torino, via Pietro Giuria 1, I-10125 Torino (Italy); Milisavljevic, D.; Paggi, A.; Smith, Howard A. [Harvard—Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Landoni, M. [INAF-Osservatorio Astronomico di Brera, Via Emilio Bianchi 46, I-23807 Merate (Italy); Chavushyan, V.; Patiño-Álvarez, V. [Instituto Nacional de Astrofísica, Óptica y Electrónica, Apartado Postal 51-216, 72000 Puebla, México (Mexico); Masetti, N. [INAF—Istituto di Astrofisica Spaziale e Fisica Cosmica di Bologna, via Gobetti 101, I-40129, Bologna (Italy); Jiménez-Bailón, E. [Instituto de Astronomía, Universidad Nacional Autónoma de México, Apdo. Postal 877, Ensenada, 22800 Baja California, México (Mexico); Strader, J.; Chomiuk, L. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Katagiri, H.; Kagaya, M. [College of Science, Ibaraki University, 2-1-1, Bunkyo, Mito 310-8512 (Japan); Cheung, C. C. [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States); D’Abrusco, R. [Department of Physical Sciences, University of Napoli Federico II, via Cinthia 9, I-80126 Napoli (Italy); Ricci, F.; La Franca, F. [Dipartimento di Matematica e Fisica, Università Roma Tre, via della Vasca Navale 84, I-00146, Roma (Italy); and others

    2016-04-15

    Blazars, one of the most extreme classes of active galaxies, constitute so far the largest known population of γ-ray sources, and their number is continuously growing in the Fermi catalogs. However, in the latest release of the Fermi catalog there is still a large fraction of sources that are classified as blazar candidates of uncertain type (BCUs) for which optical spectroscopic observations are necessary to confirm their nature and their associations. In addition, about one-third of the γ-ray point sources listed in the Third Fermi-LAT Source Catalog (3FGL) are still unassociated and lacking an assigned lower-energy counterpart. Since 2012 we have been carrying out an optical spectroscopic campaign to observe blazar candidates to confirm their nature. In this paper, the sixth of the series, we present optical spectroscopic observations for 30 γ-ray blazar candidates from different observing programs we carried out with the Telescopio Nazionale Galileo, William Herschel Telescope, Observatorio Astronómico Nacional, Southern Astrophysical Research Telescope, and Magellan Telescopes. We found that 21 out of 30 sources investigated are BL Lac objects, while the remaining targets are classified as flat-spectrum radio quasars showing the typical broad emission lines of normal quasi-stellar objects. We conclude that our selection of γ-ray blazar candidates based on their multifrequency properties continues to be a successful way to discover potential low-energy counterparts of the Fermi unidentified gamma-ray sources and to confirm the nature of BCUs.

  9. Characterization of nanocrystalline zirconia powders by electron optical techniques

    International Nuclear Information System (INIS)

    Bursill, L.A.

    1989-01-01

    Electron optical techniques are described for the characterization of the size distribution of agglomerates, aggregates and primary micro- and nanocrystallites of as-processed zirconia powders. These techniques allow for direct identification of individual crystallites as tetragonal or monoclinic, by optical transform of high-resolution electron micrographs. The latter also permit surface morphology to be examined with atomic resolution. Applications to a range of pure and doped zirconia powders, of recent commercial interest, are presented, which enable the results of concurrent studies by sedimentation, surface specific area measurements, porosity and sinterability to be correctly interpreted. 18 figs

  10. Electrochemical and spectroscopic in situ techniques for the investigation of the phosphating of zinc coated steel

    International Nuclear Information System (INIS)

    Tomandl, A.

    2003-05-01

    In this work spectroscopic and electrochemical techniques were developed for the investigation of surface treatments used in steel industry. ICP-atomic emission spectroscopy (ICP-AES), Raman spectroscopy and the Quartz crystal microbalance (QCM) were applied to the investigation of the kinetics of phosphating as well as the properties of phosphate layers. Phosphating of zinc coated steel leads to the formation of a crystalline layer consisting of zinc phosphate and is employed to enhance paint adhesion and corrosion protection. For the high reaction rates necessary in industrial production lines, oxidation agents are added to the phosphating bathes to accelerate the reaction. The oxidation agents provide an additional reduction reaction beside the hydrogen formation and therefore decrease the number of gas bubbles, which would block the zinc surface and reduce the rate of phosphating. With addition of H2O2 or nitrates the rate of layer formation is distinctly increased. In a combined experiment of ICP-AES with QCM and potential transients, it was shown that the presence of these accelerators in the phosphating bath increases the rate of zinc dissolution and hence leads to a faster formation of the phosphate layer. In under paint corrosion of painted, zinc coated steel phosphate layers are exposed to a highly alkaline environment. The stability of a phosphate layer against alkaline attack is therefore essential for its performance in corrosion protection. To enhance the alkaline stability Mn and Ni are added to modern phosphating bathes. The incorporation of these elements reduces the dissolution rate in 0.1 M NaOH proportional to their concentration in the phosphate layer. The dissolution of Zn, P, Mn and Ni was determined quantitatively with ICP-AES. Raman spectroscopy showed the formation of a Mn-hydroxide layer during alkaline attack, which protects the phosphate layer and reduces further dissolution. On basis of these results the reaction of phosphate layers

  11. Speciation of water soluble iron in size segregated airborne particulate matter using LED based liquid waveguide with a novel dispersive absorption spectroscopic measurement technique

    International Nuclear Information System (INIS)

    Chan, K.L.; Jiang, S.Y.N.; Ning, Z.

    2016-01-01

    In this study, we present the development and evaluation of a dispersive absorption spectroscopic technique for trace level soluble ferrous detection. The technique makes use of the broadband absorption spectra of the ferrous-ferrozine complex with a novel spectral fitting algorithm to determine soluble ferrous concentrations in samples and achieves much improved measurement precision compared to conventional methods. The developed method was evaluated by both model simulations and experimental investigations. The results demonstrated the robustness of the method against the spectral fluctuation, wavelength drift and electronic noise, while achieving excellent linearity (R 2  > 0.999) and low detection limit (0.06 μg L −1 ) for soluble ferrous detection. The developed method was also used for the speciation of soluble iron in size segregated atmospheric aerosols. The measurement was carried out during Spring and Summer in typical urban environment in Hong Kong. The measured total iron concentrations are in good agreement compared to conventional Inductively Coupled Plasma – Optical Emission Spectroscopy (ICP-OES) measurements. Investigation on ambient particulate matter samples shows the size dependent characteristic of iron speciation in the atmosphere with a more active role of fine particles in transforming between ferrous and ferric. The method demonstrated in this study provides a cost and time effective approach for the speciation of iron in ambient aerosols. - Highlights: • Dispersive absorption spectroscopic technique for trace level ferrous detection. • The spectral fitting retrieval improved the measurement precision and stability. • Extremely low detection limit was achieved for aqueous ferrous measurement. • Iron in size segregated particulate matters shows seasonal characteristic. • More active role of iron was found in fine particles compared to coarse particles.

  12. Speciation of water soluble iron in size segregated airborne particulate matter using LED based liquid waveguide with a novel dispersive absorption spectroscopic measurement technique

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K.L. [Meteorological Institute, Ludwig Maximilian University of Munich, Munich (Germany); School of Energy and Environment, City University of Hong Kong (Hong Kong); Jiang, S.Y.N. [School of Energy and Environment, City University of Hong Kong (Hong Kong); Ning, Z., E-mail: zhining@cityu.edu.hk [School of Energy and Environment, City University of Hong Kong (Hong Kong); Guy Carpenter Climate Change Centre, City University of Hong Kong (Hong Kong)

    2016-03-31

    In this study, we present the development and evaluation of a dispersive absorption spectroscopic technique for trace level soluble ferrous detection. The technique makes use of the broadband absorption spectra of the ferrous-ferrozine complex with a novel spectral fitting algorithm to determine soluble ferrous concentrations in samples and achieves much improved measurement precision compared to conventional methods. The developed method was evaluated by both model simulations and experimental investigations. The results demonstrated the robustness of the method against the spectral fluctuation, wavelength drift and electronic noise, while achieving excellent linearity (R{sup 2} > 0.999) and low detection limit (0.06 μg L{sup −1}) for soluble ferrous detection. The developed method was also used for the speciation of soluble iron in size segregated atmospheric aerosols. The measurement was carried out during Spring and Summer in typical urban environment in Hong Kong. The measured total iron concentrations are in good agreement compared to conventional Inductively Coupled Plasma – Optical Emission Spectroscopy (ICP-OES) measurements. Investigation on ambient particulate matter samples shows the size dependent characteristic of iron speciation in the atmosphere with a more active role of fine particles in transforming between ferrous and ferric. The method demonstrated in this study provides a cost and time effective approach for the speciation of iron in ambient aerosols. - Highlights: • Dispersive absorption spectroscopic technique for trace level ferrous detection. • The spectral fitting retrieval improved the measurement precision and stability. • Extremely low detection limit was achieved for aqueous ferrous measurement. • Iron in size segregated particulate matters shows seasonal characteristic. • More active role of iron was found in fine particles compared to coarse particles.

  13. Optical supervised filtering technique based on Hopfield neural network

    Science.gov (United States)

    Bal, Abdullah

    2004-11-01

    Hopfield neural network is commonly preferred for optimization problems. In image segmentation, conventional Hopfield neural networks (HNN) are formulated as a cost-function-minimization problem to perform gray level thresholding on the image histogram or the pixels' gray levels arranged in a one-dimensional array [R. Sammouda, N. Niki, H. Nishitani, Pattern Rec. 30 (1997) 921-927; K.S. Cheng, J.S. Lin, C.W. Mao, IEEE Trans. Med. Imag. 15 (1996) 560-567; C. Chang, P. Chung, Image and Vision comp. 19 (2001) 669-678]. In this paper, a new high speed supervised filtering technique is proposed for image feature extraction and enhancement problems by modifying the conventional HNN. The essential improvement in this technique is to use 2D convolution operation instead of weight-matrix multiplication. Thereby, neural network based a new filtering technique has been obtained that is required just 3 × 3 sized filter mask matrix instead of large size weight coefficient matrix. Optical implementation of the proposed filtering technique is executed easily using the joint transform correlator. The requirement of non-negative data for optical implementation is provided by bias technique to convert the bipolar data to non-negative data. Simulation results of the proposed optical supervised filtering technique are reported for various feature extraction problems such as edge detection, corner detection, horizontal and vertical line extraction, and fingerprint enhancement.

  14. OPTICAL SPECTROSCOPIC OBSERVATIONS OF GAMMA-RAY BLAZAR CANDIDATES. IV. RESULTS OF THE 2014 FOLLOW-UP CAMPAIGN

    International Nuclear Information System (INIS)

    Ricci, F.; Massaro, F.; Landoni, M.; D’Abrusco, R.; Milisavljevic, D.; Paggi, A.; Smith, Howard A.; Stern, D.; Masetti, N.; Tosti, G.

    2015-01-01

    The extragalactic γ-ray sky is dominated by the emission arising from blazars, one of the most peculiar classes of radio-loud active galaxies. Since the launch of Fermi several methods were developed to search for blazars as potential counterparts of unidentified γ-ray sources (UGSs). To confirm the nature of the selected candidates, optical spectroscopic observations are necessary. In 2013 we started a spectroscopic campaign to investigate γ-ray blazar candidates selected according to different procedures. The main goals of our campaign are: (1) to confirm the nature of these candidates, and (2) whenever possible, determine their redshifts. Optical spectroscopic observations will also permit us to verify the robustness of the proposed associations and check for the presence of possible source class contaminants to our counterpart selection. This paper reports the results of observations carried out in 2014 in the northern hemisphere with Kitt Peak National Observatory and in the southern hemisphere with the Southern Astrophysical Research telescopes. We also report three sources observed with the Magellan and Palomar telescopes. Our selection of blazar-like sources that could be potential counterparts of UGSs is based on their peculiar infrared colors and on their combination with radio observations both at high and low frequencies (i.e., above and below ∼1 GHz) in publicly available large radio surveys. We present the optical spectra of 27 objects. We confirm the blazar-like nature of nine sources that appear to be potential low-energy counterparts of UGSs. Then we present new spectroscopic observations of 10 active galaxies of uncertain type associated with Fermi sources, classifying all of them as blazars. In addition, we present the spectra for five known γ-ray blazars with uncertain redshift estimates and three BL Lac candidates that were observed during our campaign. We also report the case for WISE J173052.85−035247.2, candidate counterpart of the

  15. OPTICAL SPECTROSCOPIC OBSERVATIONS OF GAMMA-RAY BLAZAR CANDIDATES. IV. RESULTS OF THE 2014 FOLLOW-UP CAMPAIGN

    Energy Technology Data Exchange (ETDEWEB)

    Ricci, F. [Dipartimento di Matematica e Fisica, Università Roma Tre, via della Vasca Navale 84, I-00146, Roma (Italy); Massaro, F. [Dipartimento di Fisica, Università degli Studi di Torino, via Pietro Giuria 1, I-10125 Torino (Italy); Landoni, M. [INAF-Osservatorio Astronomico di Brera, Via Emilio Bianchi 46, I-23807 Merate (Italy); D’Abrusco, R.; Milisavljevic, D.; Paggi, A.; Smith, Howard A. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Stern, D. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Mail Stop 169-221, Pasadena, CA 91109 (United States); Masetti, N. [INAF-Istituto di Astrofisica Spaziale e Fisica Cosmica di Bologna, via Gobetti 101, I-40129, Bologna (Italy); Tosti, G., E-mail: riccif@fis.uniroma3.it [Dipartimento di Fisica, Università degli Studi di Perugia, I-06123 Perugia (Italy)

    2015-05-15

    The extragalactic γ-ray sky is dominated by the emission arising from blazars, one of the most peculiar classes of radio-loud active galaxies. Since the launch of Fermi several methods were developed to search for blazars as potential counterparts of unidentified γ-ray sources (UGSs). To confirm the nature of the selected candidates, optical spectroscopic observations are necessary. In 2013 we started a spectroscopic campaign to investigate γ-ray blazar candidates selected according to different procedures. The main goals of our campaign are: (1) to confirm the nature of these candidates, and (2) whenever possible, determine their redshifts. Optical spectroscopic observations will also permit us to verify the robustness of the proposed associations and check for the presence of possible source class contaminants to our counterpart selection. This paper reports the results of observations carried out in 2014 in the northern hemisphere with Kitt Peak National Observatory and in the southern hemisphere with the Southern Astrophysical Research telescopes. We also report three sources observed with the Magellan and Palomar telescopes. Our selection of blazar-like sources that could be potential counterparts of UGSs is based on their peculiar infrared colors and on their combination with radio observations both at high and low frequencies (i.e., above and below ∼1 GHz) in publicly available large radio surveys. We present the optical spectra of 27 objects. We confirm the blazar-like nature of nine sources that appear to be potential low-energy counterparts of UGSs. Then we present new spectroscopic observations of 10 active galaxies of uncertain type associated with Fermi sources, classifying all of them as blazars. In addition, we present the spectra for five known γ-ray blazars with uncertain redshift estimates and three BL Lac candidates that were observed during our campaign. We also report the case for WISE J173052.85−035247.2, candidate counterpart of the

  16. Portable optical fiber probe-based spectroscopic scanner for rapid cancer diagnosis: a new tool for intraoperative margin assessment.

    Directory of Open Access Journals (Sweden)

    Niyom Lue

    Full Text Available There continues to be a significant clinical need for rapid and reliable intraoperative margin assessment during cancer surgery. Here we describe a portable, quantitative, optical fiber probe-based, spectroscopic tissue scanner designed for intraoperative diagnostic imaging of surgical margins, which we tested in a proof of concept study in human tissue for breast cancer diagnosis. The tissue scanner combines both diffuse reflectance spectroscopy (DRS and intrinsic fluorescence spectroscopy (IFS, and has hyperspectral imaging capability, acquiring full DRS and IFS spectra for each scanned image pixel. Modeling of the DRS and IFS spectra yields quantitative parameters that reflect the metabolic, biochemical and morphological state of tissue, which are translated into disease diagnosis. The tissue scanner has high spatial resolution (0.25 mm over a wide field of view (10 cm × 10 cm, and both high spectral resolution (2 nm and high spectral contrast, readily distinguishing tissues with widely varying optical properties (bone, skeletal muscle, fat and connective tissue. Tissue-simulating phantom experiments confirm that the tissue scanner can quantitatively measure spectral parameters, such as hemoglobin concentration, in a physiologically relevant range with a high degree of accuracy (<5% error. Finally, studies using human breast tissues showed that the tissue scanner can detect small foci of breast cancer in a background of normal breast tissue. This tissue scanner is simpler in design, images a larger field of view at higher resolution and provides a more physically meaningful tissue diagnosis than other spectroscopic imaging systems currently reported in literatures. We believe this spectroscopic tissue scanner can provide real-time, comprehensive diagnostic imaging of surgical margins in excised tissues, overcoming the sampling limitation in current histopathology margin assessment. As such it is a significant step in the development of a

  17. A spectroscopic survey of the youngest field stars in the solar neighborhood . II. The optically faint sample

    Science.gov (United States)

    Frasca, A.; Guillout, P.; Klutsch, A.; Ferrero, R. Freire; Marilli, E.; Biazzo, K.; Gandolfi, D.; Montes, D.

    2018-05-01

    Context. Star formation in the solar neighborhood is mainly traced by young stars in open clusters, associations, and in the field, which can be identified, for example, by their X-ray emission. The determination of stellar parameters for the optical counterparts of X-ray sources is crucial for a full characterization of these stars. Aims: This work extends the spectroscopic study of the RasTyc sample, obtained by the cross-correlation of the Tycho and ROSAT All-Sky Survey catalogs, to stars fainter than V = 9.5 mag and aims to identify sparse populations of young stars in the solar neighborhood. Methods: We acquired 625 high-resolution spectra for 443 presumably young stars with four different instruments in the northern hemisphere. The radial and rotational velocity (vsini) of our targets were measured by means of the cross-correlation technique, which is also helpful to discover single-lined (SB1), double-lined spectroscopic binaries (SB2), and multiple systems. We used the code ROTFIT to perform an MK spectral classification and to determine the atmospheric parameters (Teff, logg, [Fe/H]) and vsini of the single stars and SB1 systems. For these objects, we used the spectral subtraction of slowly rotating templates to measure the equivalent widths of the Hα and Li I 6708 Å lines, which enabled us to derive their chromospheric activity level and lithium abundance. We made use of Gaia DR1 parallaxes and proper motions to locate the targets in the Hertzsprung-Russell (HR) diagram and to compute the space velocity components of the youngest objects. Results: We find a remarkable percentage (at least 35%) of binaries and multiple systems. On the basis of the lithium abundance, the sample of single stars and SB1 systems appears to be mostly ( 60%) composed of stars younger than the members of the UMa cluster. The remaining sources are in the age range between the UMa and Hyades clusters ( 20%) or older ( 20%). In total, we identify 42 very young (PMS-like) stars

  18. Spectroscopic techniques (Moessbauer spectrometry, NMR, ESR...) as tools to resolve doubtful NMR images: Study of the craniopharyngioma tumor

    International Nuclear Information System (INIS)

    Rimbert, J.N.; Dumas, F.; Lafargue, C.; Kellershohn, C.; Brunelle, F.; Lallemand, D.

    1990-01-01

    Craniopharyngioma, an intracranial tumor, exhibits hyperintensity in the Spin-Echo-T 2 -NMR image and a hyposignal in the SE-T 1 -image. However, in some cases (15-20% cases), hypersignals are seen in both SE-T 1 and T 2 -MRI. Using spectroscopic techniques, Moessbauer spectrometry in particular, we have demonstrated that the T 1 hypersignal is due to ferritin, dissolved in the cystic liquid, after tumor cell lysis, in the course of time. Other possible reasons inducing a shortening of the T 1 relaxation time (presence of lipids, intratumoral hemorrhage) have been rejected. (orig.)

  19. Nanosecond and femtosecond mass spectroscopic analysis of a molecular beam produced by the spray-jet technique

    International Nuclear Information System (INIS)

    Yamada, Toshiki; Shinohara, Hidenori; Kamikado, Toshiya; Okuno, Yoshishige; Suzuki, Hitoshi; Mashiko, Shinro; Yokoyama, Shiyoshi

    2008-01-01

    The spray-jet molecular beam apparatus enabled us to produce a molecular beam of non-volatile molecules under high vacuum from a sprayed mist of sample solutions. The apparatus has been used in spectroscopic studies and as a means of molecular beam deposition. We analyzed the molecular beam, consisting of non-volatile, solvent, and carrier-gas molecules, by using femtosecond- and nanosecond- laser mass spectroscopy. The information thus obtained provided insight into the molecular beam produced by the spray-jet technique

  20. Spectroscopic classification of transients

    DEFF Research Database (Denmark)

    Stritzinger, M. D.; Fraser, M.; Hummelmose, N. N.

    2017-01-01

    We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017.......We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017....

  1. Early detection of chemotherapy-refractory patients by monitoring textural alterations in diffuse optical spectroscopic images

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi-Naini, Ali; Falou, Omar; Czarnota, Gregory J., E-mail: Gregory.Czarnota@sunnybrook.ca [Physical Sciences, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Vorauer, Eric [Department of Medical Physics, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Physics, Ryerson University, Toronto, Ontario M5B 2K3 (Canada); Chin, Lee [Department of Radiation Oncology, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Physics, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Physics, Ryerson University, Toronto, Ontario M5B 2K3 (Canada); Tran, William T. [Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Wright, Frances C. [Division of General Surgery, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Surgery, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Gandhi, Sonal [Division of Medical Oncology, Sunnybrook Health Sciences Centre, and Faculty of Medicine, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Yaffe, Martin J. [Physical Sciences, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario M4N 3M5 (Canada)

    2015-11-15

    Purpose: Changes in textural characteristics of diffuse optical spectroscopic (DOS) functional images, accompanied by alterations in their mean values, are demonstrated here for the first time as early surrogates of ultimate treatment response in locally advanced breast cancer (LABC) patients receiving neoadjuvant chemotherapy (NAC). NAC, as a standard component of treatment for LABC patient, induces measurable heterogeneous changes in tumor metabolism which were evaluated using DOS-based metabolic maps. This study characterizes such inhomogeneous nature of response development, by determining alterations in textural properties of DOS images apparent at early stages of therapy, followed later by gross changes in mean values of these functional metabolic maps. Methods: Twelve LABC patients undergoing NAC were scanned before and at four times after treatment initiation, and tomographic DOS images were reconstructed at each time. Ultimate responses of patients were determined clinically and pathologically, based on a reduction in tumor size and assessment of residual tumor cellularity. The mean-value parameters and textural features were extracted from volumetric DOS images for several functional and metabolic parameters prior to the treatment initiation. Changes in these DOS-based biomarkers were also monitored over the course of treatment. The measured biomarkers were applied to differentiate patient responses noninvasively and compared to clinical and pathologic responses. Results: Responding and nonresponding patients demonstrated different changes in DOS-based textural and mean-value parameters during chemotherapy. Whereas none of the biomarkers measured prior the start of therapy demonstrated a significant difference between the two patient populations, statistically significant differences were observed at week one after treatment initiation using the relative change in contrast/homogeneity of seven functional maps (0.001 < p < 0.049), and mean value of water

  2. Diagnostics of gas behind shock waves by refractive optical techniques

    International Nuclear Information System (INIS)

    Blaha, J.

    In a brief outline of optical methods for measuring neutral gas and plasma parameters, techniques are specifically dealt with based on the interferometric measurement of the refractive index. The investigation is shown of gas density changes in a shock tube using the optical Mach-Zehnder interferometer. While in a neutral gas the refractive index is determined by gas density, in a plasma the effects of all components, ie., electrons, ions and atoms are additive. The contributions to refraction from the various components may, in view of the different character and frequencies of the components, be resolved by measurement on more than one wavelength. (J.U.)

  3. Fundamentals and techniques of nonimaging optics, volume 2

    Science.gov (United States)

    Winston, R.; Ogallagher, J. J.

    1983-06-01

    The formalism describing the operation is being defined, nonimaging concentrators and are being designed, and experiments and analytical studies are being conducted to evaluate the performance of new designs. In addition, components and materials particularly suited for use with these techniques were studied, and applications with an emphasis on solar energy concentration were explored. The motivation for the basic principles of nonimaging optics as they developed before 1978 are surveyed. The present status of the subdiscipline of nonimaging optics is summarized and an overview of the potential for future developments which is just beginning to emerge is presented.

  4. Optical gradients in a-Si:H thin films detected using real-time spectroscopic ellipsometry with virtual interface analysis

    Science.gov (United States)

    Junda, Maxwell M.; Karki Gautam, Laxmi; Collins, Robert W.; Podraza, Nikolas J.

    2018-04-01

    Virtual interface analysis (VIA) is applied to real time spectroscopic ellipsometry measurements taken during the growth of hydrogenated amorphous silicon (a-Si:H) thin films using various hydrogen dilutions of precursor gases and on different substrates during plasma enhanced chemical vapor deposition. A procedure is developed for optimizing VIA model configurations by adjusting sampling depth into the film and the analyzed spectral range such that model fits with the lowest possible error function are achieved. The optimal VIA configurations are found to be different depending on hydrogen dilution, substrate composition, and instantaneous film thickness. A depth profile in the optical properties of the films is then extracted that results from a variation in an optical absorption broadening parameter in a parametric a-Si:H model as a function of film thickness during deposition. Previously identified relationships are used linking this broadening parameter to the overall shape of the optical properties. This parameter is observed to converge after about 2000-3000 Å of accumulated thickness in all layers, implying that similar order in the a-Si:H network can be reached after sufficient thicknesses. In the early stages of growth, however, significant variations in broadening resulting from substrate- and processing-induced order are detected and tracked as a function of bulk layer thickness yielding an optical property depth profile in the final film. The best results are achieved with the simplest film-on-substrate structures while limitations are identified in cases where films have been deposited on more complex substrate structures.

  5. Studies on the binding behavior of prodigiosin with bovine hemoglobin by multi-spectroscopic techniques

    Science.gov (United States)

    Tang, Jing; Yang, Chao; Zhou, Lin; Ma, Fei; Liu, Shuchao; Wei, Shaohua; Zhou, Jiahong; Zhou, Yanhuai

    2012-10-01

    In this article, the interaction mechanism of prodigiosin (PG) with bovine hemoglobin (BHb) is studied in detail using various spectroscopic technologies. UV-vis absorption and fluorescence spectra demonstrate the interaction process. The Stern-Volmer plot and the time-resolved fluorescence study suggest the quenching mechanism of fluorescence of BHb by PG is a static quenching procedure, and the hydrophobic interactions play a major role in binding of PG to BHb. Furthermore, synchronous fluorescence studies, Fourier transform infrared (FTIR) and circular dichroism (CD) spectra reveal that the conformation of BHb is changed after conjugation with PG.

  6. Optical Spectroscopic Observations of γ-Ray Blazar Candidates. III. The 2013/2014 Campaign in the Southern Hemisphere

    Science.gov (United States)

    Landoni, M.; Massaro, F.; Paggi, A.; D'Abrusco, R.; Milisavljevic, D.; Masetti, N.; Smith, H. A.; Tosti, G.; Chomiuk, L.; Strader, J.; Cheung, C. C.

    2015-05-01

    We report the results of our exploratory program carried out with the southern Astrophysical Research telescope aimed at associating counterparts and establishing the nature of the Fermi Unidentified γ-ray Sources (UGSs). We selected the optical counterparts of six UGSs from the Fermi catalog on the basis of our recently discovered tight connection between infrared and γ-ray emission found for the γ-ray blazars detected by the Wide-Field Infrared Survey Explorer in its all-sky survey. We perform for the first time a spectroscopic study of the low-energy counterparts of the Fermi UGSs, in the optical band, confirming the blazar-like nature of the whole sample. We also present new spectroscopic observations of six active galaxies of uncertain type associated with Fermi sources which appear to be BL Lac objects. Finally, we report the spectra collected for six known γ-ray blazars belonging to the Roma BZCAT that were obtained to establish their nature or better estimate their redshifts. Two interesting cases of high redshift and extremely luminous BL Lac objects (z ≥ 1.18 and z ≥ 1.02, based on the detection of Mg ii intervening systems) are also discussed. Based on observations obtained at the southern Astrophysical Research (SOAR) telescope, which is a joint project of the Ministério da Ciência, Tecnologia, e Inovação (MCTI) da República Federativa do Brasil, the U.S. National Optical Astronomy Observatory (NOAO), the University of North Carolina at Chapel Hill (UNC), and Michigan State University (MSU).

  7. Optical and infrared spectroscopic studies of chemical sensing by copper phthalocyanine thin films

    International Nuclear Information System (INIS)

    Singh, Sukhwinder; Tripathi, S.K.; Saini, G.S.S.

    2008-01-01

    Thin films of copper phthalocyanine have been deposited on KBr and glass substrates by thermal evaporation method and characterized by the X-ray diffraction and optical absorption techniques. The observed X-ray pattern suggests the presence of α crystalline phase of copper phthalocyanine in the as-deposited thin films. Infrared spectra of thin films on the KBr pallet before and after exposure to the vapours of ammonia and methanol have been recorded in the wavenumber region of 400-1650 cm -1 . The observed infrared bands also confirm the α crystalline phase. On exposure, change in the intensity of some bands is observed. A new band at 1385 cm -1 , forbidden under ideal D 4h point group symmetry, is also observed in the spectra of exposed thin films. These changes in the spectra are interpreted in terms of the lowering of molecular symmetry from D 4h to C 4v . Axial ligation of the vapour molecules on fifth coordination site of the metal ion is responsible for lowering of the molecular symmetry

  8. Optical spectroscopic elucidation of beta-turns in disulfide bridged cyclic tetrapeptides.

    Science.gov (United States)

    Borics, Attila; Murphy, Richard F; Lovas, Sándor

    2007-01-01

    Vibrational circular dichroism (VCD) spectroscopic features of type II beta-turns were characterized previously, but, criteria for differentiation between beta-turn types had not been established yet. Model tetrapeptides, cyclized through a disulfide bridge, were designed on the basis of previous experimental results and the observed incidence of amino acid residues in the i + 1 and i + 2 positions in beta-turns, to determine the features of VCD spectra of type I and II beta-turns. The results were correlated with electronic circular dichroism (ECD) spectra and VCD spectra calculated from conformational data obtained by molecular dynamics (MD) simulations. All cyclic tetrapeptides yielded VCD signals with a higher frequency negative and a lower frequency positive couplet with negative lobes overlapping. MD simulations confirmed the conformational homogeneity of these peptides in solution. Comparison with ECD spectroscopy, MD, and quantum chemical calculation results suggested that the low frequency component of VCD spectra originating from the tertiary amide vibrations could be used to distinguish between types of beta-turn structures. On the basis of this observation, VCD spectroscopic features of type II and VIII beta-turns and ECD spectroscopic properties of a type VIII beta-turn were suggested. The need for independent experimental as well as theoretical investigations to obtain decisive conformational information was recognized. Copyright 2006 Wiley Periodicals, Inc.

  9. All-optical delay technique for supporting multiple antennas in a hybrid optical - wireless transmission system

    DEFF Research Database (Denmark)

    Prince, Kamau; Chiuchiarelli, A; Presi, M

    2008-01-01

    We introduce a novel continuously-variable optical delay technique to support beam-forming wireless communications systems using antenna arrays. We demonstrate delay with 64-QAM modulated signals at a rate of 15 Msymbol/sec with 2.5 GHz carrier frequency.......We introduce a novel continuously-variable optical delay technique to support beam-forming wireless communications systems using antenna arrays. We demonstrate delay with 64-QAM modulated signals at a rate of 15 Msymbol/sec with 2.5 GHz carrier frequency....

  10. Optical fiber sensors fabricated by the focused ion beam technique

    DEFF Research Database (Denmark)

    Yuan, Scott Wu; Wang, Fei; Bang, Ole

    2012-01-01

    crystal fiber (PCF). Using this technique we fabricate a highly compact fiber-optic Fabry-Pérot (FP) refractive index sensor near the tip of fiber taper, and a highly sensitive in-line temperature sensor in PCF. We also demonstrate the potential of using FIB to selectively fill functional fluid......Focused ion beam (FIB) is a highly versatile technique which helps to enable next generation of lab-on-fiber sensor technologies. In this paper, we demonstrate the use application of FIB to precisely mill the fiber taper and end facet of both conventional single mode fiber (SMF) and photonic...

  11. Optical, infrared and radio astronomy from techniques to observation

    CERN Document Server

    Poggiani, Rosa

    2017-01-01

    This textbook presents the established sciences of optical, infrared, and radio astronomy as distinct research areas, focusing on the science targets and the constraints that they place on instrumentation in the different domains. It aims to bridge the gap between specialized books and practical texts, presenting the state of the art in different techniques. For each type of astronomy, the discussion proceeds from the orders of magnitude for observable quantities that drive the building of instrumentation and the development of advanced techniques. The specific telescopes and detectors are then presented, together with the techniques used to measure fluxes and spectra. Finally, the instruments and their limits are discussed to assist readers in choice of setup, planning and execution of observations, and data reduction. The volume also includes worked examples and problem sets to improve student understanding; tables and figures in chapters summarize the state of the art of instrumentation and techniques.

  12. Optical signal processing techniques and applications of optical phase modulation in high-speed communication systems

    Science.gov (United States)

    Deng, Ning

    the speed limitation of electronics. Thus, all-optical signal processing techniques are highly desirable to support the necessary optical switching functionalities in future ultrahigh-speed optical packet-switching networks. To cope with the wide use of optical phase-modulated signals, in the thesis, an all-optical logic for DPSK or PSK input signals is developed, for the first time. Based on four-wave mixing in semiconductor optical amplifier, the structure of the logic gate is simple, compact, and capable of supporting ultrafast operation. In addition to the general logic processing, a simple label recognition scheme, as a specific signal processing function, is proposed for phase-modulated label signals. The proposed scheme can recognize any incoming label pattern according to the local pattern, and is potentially capable of handling variable-length label patterns. Optical access network with multicast overlay and centralized light sources. In the arena of optical access networks, wavelength division multiplexing passive optical network (WDM-PON) is a promising technology to deliver high-speed data traffic. However, most of proposed WDM-PONs only support conventional point-to-point service, and cannot meet the requirement of increasing demand on broadcast and multicast service. In this thesis, a simple network upgrade is proposed based on the traditional PON architecture to support both point-to-point and multicast service. In addition, the two service signals are modulated on the same lightwave carrier. The upstream signal is also remodulated on the same carrier at the optical network unit, which can significantly relax the requirement on wavelength management at the network unit.

  13. Optical spectroscopic observations of blazars and γ-ray blazar candidates in the sloan digital sky survey data release nine

    Energy Technology Data Exchange (ETDEWEB)

    Massaro, F.; Masetti, N.; D' Abrusco, R.; Paggi, A.; Funk, S.

    2014-09-09

    We present an analysis of the optical spectra available in the Sloan Digital Sky Survey data release nine (SDSS DR9) for the blazars listed in the ROMA-BZCAT and for the γ-ray blazar candidates selected according to their IR colors. First, we adopt a statistical approach based on Monte Carlo simulations to find the optical counterparts of the blazars listed in the ROMA-BZCAT catalog. Then, we crossmatched the SDSS spectroscopic catalog with our selected samples of blazars and γ-ray blazar candidates, searching for those with optical spectra available to classify our blazar-like sources and, whenever possible, to confirm their redshifts. Our main objectives are to determine the classification of uncertain blazars listed in the ROMA-BZCAT and to discover new gamma-ray blazars. For the ROMA-BZCAT sources, we investigated a sample of 84 blazars, confirming the classification for 20 of them and obtaining 18 new redshift estimates. For the γ-ray blazars, indicated as potential counterparts of unassociated Fermi sources or with uncertain nature, we established the blazar-like nature of 8 out of the 27 sources analyzed and confirmed 14 classifications.

  14. Optical properties of monolayer transition metal dichalcogenides probed by spectroscopic ellipsometry

    KAUST Repository

    Liu, Hsiang-Lin

    2014-11-17

    Spectroscopic ellipsometry was used to characterize the complex refractive index of chemical-vapor-deposited monolayer transition metal dichalcogenides (TMDs). The extraordinary large value of the refractive index in the visible frequency range is obtained. The absorption response shows a strong correlation between the magnitude of the exciton binding energy and band gap energy. Together with the observed giant spin-orbit splitting, these findings advance the fundamental understanding of their novel electronic structures and the development of monolayer TMDs-based optoelectronic and spintronic devices.

  15. Optical properties of monolayer transition metal dichalcogenides probed by spectroscopic ellipsometry

    KAUST Repository

    Liu, Hsiang-Lin; Shen, Chih-Chiang; Su, Sheng-Han; Hsu, Chang-Lung; Li, Ming-Yang; Li, Lain-Jong

    2014-01-01

    Spectroscopic ellipsometry was used to characterize the complex refractive index of chemical-vapor-deposited monolayer transition metal dichalcogenides (TMDs). The extraordinary large value of the refractive index in the visible frequency range is obtained. The absorption response shows a strong correlation between the magnitude of the exciton binding energy and band gap energy. Together with the observed giant spin-orbit splitting, these findings advance the fundamental understanding of their novel electronic structures and the development of monolayer TMDs-based optoelectronic and spintronic devices.

  16. Effects of thermal annealing on the optical, spectroscopic, and structural properties of tris (8-hydroxyquinolinate) gallium films grown on quartz substrates

    Energy Technology Data Exchange (ETDEWEB)

    Muhammad, Fahmi Fariq, E-mail: fahmi982@gmail.com [Low Dimensional Materials Research Center, Department of Physics, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia); Department of Physics, Faculty of Science and Engineering, University of Koya, Koya, Kurdistan Region (Iraq); Sulaiman, Khaulah [Low Dimensional Materials Research Center, Department of Physics, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2011-10-03

    Highlights: {yields} Achieving a broad absorption band for Gaq3 covering the whole UV and some parts of visible spectra. {yields} Increasing photoluminescence emission to five times stronger than that of pristine film. {yields} Conformational changes towards the formation of crystalline {alpha}-Gaq3 polymorph. {yields} Determination of glass transition temperature for Gaq3 (T{sub g} 182 deg. C) and Alq3 (T{sub g} = 173 deg. C). {yields} Improving and understanding the physical properties of Gaq3 film by means of thermal treatment. - Abstract: In this study we report the optical, spectroscopic, and structural properties of vacuum deposited tris (8-hydroxyquinolinate) gallium film upon thermal annealing in the temperature range from 85 deg. C to 255 deg. C under a flowing nitrogen gas for 10 min. The optical UV-vis-NIR and luminescence spectroscopy measurements were performed to estimate the absorption bands, optical energy gap (E{sub g}), and photoluminescence (PL) of the films. Fourier transform infrared (FTIR) spectroscopy and X-ray diffraction (XRD) techniques were used to probe the spectroscopic and structural nature of the films. We show that, by annealing the films from 85 deg. C to 235 deg. C, it is possible to achieve an enhanced absorption and increased photoluminescence to five times stronger than that of the pristine film. The PL quenching at 255 deg. C was attributed to the presence of plainer chains allow easy going for excitons to a long distance due to the crystalline region formation of {alpha}-Gaq3 polymorph. The reduction in E{sub g} and infrared absorption bands upon annealing were referred to the enhancement in {pi}-{pi} interchain interaction and conformational changes by re-arrangement of the Gaq3 quinolinate ligands, respectively. Stokes shift for the films were observed and calculated. From the differential scanning calorimetry, DSC measurements, higher glass transition temperature was observed for Gaq3 (T{sub g} = 182 deg. C) compared to

  17. Artificial neural network techniques to improve the ability of optical coherence tomography to detect optic neuritis.

    Science.gov (United States)

    Garcia-Martin, Elena; Herrero, Raquel; Bambo, Maria P; Ara, Jose R; Martin, Jesus; Polo, Vicente; Larrosa, Jose M; Garcia-Feijoo, Julian; Pablo, Luis E

    2015-01-01

    To analyze the ability of Spectralis optical coherence tomography (OCT) to detect multiple sclerosis (MS) and to distinguish MS eyes with antecedent optic neuritis (ON). To analyze the capability of artificial neural network (ANN) techniques to improve the diagnostic precision. MS patients and controls were enrolled (n = 217). OCT was used to determine the 768 retinal nerve fiber layer thicknesses. Sensitivity and specificity were evaluated to test the ability of OCT to discriminate between MS and healthy eyes, and between MS with and without antecedent ON using ANN. Using ANN technique multilayer perceptrons, OCT could detect MS with a sensitivity of 89.3%, a specificity of 87.6%, and a diagnostic precision of 88.5%. Compared with the OCT-provided parameters, the ANN had a better sensitivity-specificity balance. ANN technique improves the capability of Spectralis OCT to detect MS disease and to distinguish MS eyes with or without antecedent ON.

  18. Optical modulation techniques for analog signal processing and CMOS compatible electro-optic modulation

    Science.gov (United States)

    Gill, Douglas M.; Rasras, Mahmoud; Tu, Kun-Yii; Chen, Young-Kai; White, Alice E.; Patel, Sanjay S.; Carothers, Daniel; Pomerene, Andrew; Kamocsai, Robert; Beattie, James; Kopa, Anthony; Apsel, Alyssa; Beals, Mark; Mitchel, Jurgen; Liu, Jifeng; Kimerling, Lionel C.

    2008-02-01

    Integrating electronic and photonic functions onto a single silicon-based chip using techniques compatible with mass-production CMOS electronics will enable new design paradigms for existing system architectures and open new opportunities for electro-optic applications with the potential to dramatically change the management, cost, footprint, weight, and power consumption of today's communication systems. While broadband analog system applications represent a smaller volume market than that for digital data transmission, there are significant deployments of analog electro-optic systems for commercial and military applications. Broadband linear modulation is a critical building block in optical analog signal processing and also could have significant applications in digital communication systems. Recently, broadband electro-optic modulators on a silicon platform have been demonstrated based on the plasma dispersion effect. The use of the plasma dispersion effect within a CMOS compatible waveguide creates new challenges and opportunities for analog signal processing since the index and propagation loss change within the waveguide during modulation. We will review the current status of silicon-based electrooptic modulators and also linearization techniques for optical modulation.

  19. Improvement of the inlet system for the spray-jet technique for use in spectroscopic studies and molecular deposition

    International Nuclear Information System (INIS)

    Yamada, Toshiki; Shinohara, Hidenori; Mashiko, Shinro

    2006-01-01

    We previously developed a molecular beam apparatus with a spray-jet technique in order to produce a molecular beam of non-volatile molecules in vacuum from the sprayed mist of a sample solution. The apparatus is for use in spectroscopic studies or a means of molecular deposition. The spray-jet inlet system consisted of an ultrasonic nebulizer, an inlet chamber and a pulsed nozzle. In the present paper, further improvements to the spray-jet inlet system are reported. The main improvement is the introduction of a pneumatic nebulizer to replace the previous ultrasonic nebulizer. The efficiency of molecular beam generation was evaluated on the basis of the signal intensity of the resonantly enhanced multiphoton ionization time-of-flight mass (REMPI-TOFMS) spectra for a Rhodamine B/methanol solution and the amount of sample consumed. The introduction of the pneumatic nebulizer increased the efficiency by a factor of 20

  20. In vitro DNA binding studies of lenalidomide using spectroscopic in combination with molecular docking techniques

    Science.gov (United States)

    Xu, Liang; Hu, Yan-Xi; Li, Yan-Cheng; Zhang, Li; Ai, Hai-Xin; Liu, Yu-Feng; Liu, Hong-Sheng

    2018-02-01

    In the present work, the binding interaction between lenalidomide (LEN) and calf thymus DNA (ct-DNA) was systematically studied by using fluorescence, ultraviolet-visible (UV-vis) absorption, circular dichroism (CD) spectroscopies under imitated physiological conditions (pH = 7.4) coupled with molecular docking. It was found that LEN was bound to ct-DNA with high binding affinity (Ka = 2.308 × 105 M-1 at 283 K) through groove binding as evidenced by a slight decrease in the absorption intensity in combination with CD spectra. Thermodynamic parameters (ΔG 0 and ΔS interaction. Furthermore, competitive binding experiments with ethidium bromide and 4‧, 6-dia-midino-2-phenylindoleas probes showed that LEN could preferentially bind in the minor groove of double-stranded DNA. The average lifetime of LEN was calculated to be 7.645 ns. The φ of LEN was measured as 0.09 and non-radiation energy transfer between LEN and DNA had occurred. The results of the molecular docking were consistent with the experimental results. This study explored the potential applicability of the spectroscopic properties of LEN and also investigated its interactions with relevant biological targets. In addition, it will provide some theoretical references for the deep research of simultaneous administration of LEN with other drugs.

  1. Molecular structure and spectroscopic characterization of Carbamazepine with experimental techniques and DFT quantum chemical calculations

    Science.gov (United States)

    Suhasini, M.; Sailatha, E.; Gunasekaran, S.; Ramkumaar, G. R.

    2015-04-01

    A systematic vibrational spectroscopic assignment and analysis of Carbamazepine has been carried out by using FT-IR, FT-Raman and UV spectral data. The vibrational analysis were aided by electronic structure calculations - ab initio (RHF) and hybrid density functional methods (B3LYP) performed with standard basis set 6-31G(d,p). Molecular equilibrium geometries, electronic energies, natural bond order analysis, harmonic vibrational frequencies and IR intensities have been computed. A detailed interpretation of the vibrational spectra of the molecule has been made on the basis of the calculated Potential Energy Distribution (PED) by VEDA program. UV-visible spectrum of the compound was also recorded and the electronic properties, such as HOMO and LUMO energies and λmax were determined by HF/6-311++G(d,p) Time-Dependent method. The thermodynamic functions of the title molecule were also performed using the RHF and DFT methods. The restricted Hartree-Fock and density functional theory-based nuclear magnetic resonance (NMR) calculation procedure was also performed, and it was used for assigning the 13C and 1H NMR chemical shifts of Carbamazepine.

  2. Development of a THz spectroscopic imaging system

    International Nuclear Information System (INIS)

    Usami, M; Iwamoto, T; Fukasawa, R; Tani, M; Watanabe, M; Sakai, K

    2002-01-01

    We have developed a real-time THz imaging system based on the two-dimensional (2D) electro-optic (EO) sampling technique. Employing the 2D EO-sampling technique, we can obtain THz images using a CCD camera at a video rate of up to 30 frames per second. A spatial resolution of 1.4 mm was achieved. This resolution was reasonably close to the theoretical limit determined by diffraction. We observed not only static objects but also moving ones. To acquire spectroscopic information, time-domain images were collected. By processing these images on a computer, we can obtain spectroscopic images. Spectroscopy for silicon wafers was demonstrated

  3. REAL-TIME ASSESSMENT OF MICROWAVE ABLATION EFFICACY BY NIR SPECTROSCOPIC TECHNIQUE

    Directory of Open Access Journals (Sweden)

    JINZHE ZHAO

    2014-01-01

    Full Text Available Microwave ablation (MWA status monitoring in real time plays a key role in assessment of therapeutic effectiveness. As a novel real-time assessment method, near infrared spectroscopy (NIRs was used to evaluate the ablation efficacy. MWA experiments were carried out on in vitro porcine livers. An optical measurement system for biological tissue is developed by our lab to monitor reduced scattering coefficient $(\\mu_{s}^{'}$ at 690 nm of the coagulation zones. It is noted that $\\mu_{s}^{'}$ of liver tissue, which increases as the liver tissue being ablated, is clearly related with the coagulation status. $\\mu_{s}^{'}$ of normal tissue and coagulated tissue is 3–5 and 17–19 cm-1, respectively. Continuous changes of $\\mu_{s}^{'}$ demonstrate that optical parameter can be used as an efficacy evaluation factor because it essentially indicates the degree of thermal damage. Compared with temperature, optical parameter is more sensitive and accurate, which is promising for real-time therapeutic efficacy assessment in MWA.

  4. A small-volume PVTX system for broadband spectroscopic calibration of downhole optical sensors

    Science.gov (United States)

    Jones, Christopher Michael; Pelletier, Michael T.; Atkinson, Robert; Shen, Jing; Moore, Jeff; Anders, Jimmy; Perkins, David L.; Myrick, Michael L.

    2017-07-01

    An instrument is presented that is capable of measuring the optical spectrum (long-wave ultraviolet through short-wave mid-infrared) of fluids under a range of temperature and pressure conditions from ambient pressure up to 138 MPa (20 000 psi) and 422 K (300 °F) using ˜5 ml of fluid. Temperature, pressure, and density are measured in situ in real-time, and composition is varied by adding volatile and nonvolatile components. The stability and accuracy of the conditions are reported for pure ethane, and the effects of temperature and pressure on characteristic regions of the optical spectrum of ethane are illustrated after correction for temperature and pressure effects on the optical cell path length, as well as normalization to the measured density. Molar absorption coefficients and integrated molar absorption coefficients for several vibrational combination bands are presented.

  5. Mechanical characterization of composite materials by optical techniques: A review

    Science.gov (United States)

    Bruno, Luigi

    2018-05-01

    The present review provides an overview of work published in recent years dealing with the mechanical characterization of composite materials performed by optical techniques. The paper emphasizes the strengths derived from the employment of full-field methods when the strain field of an anisotropic material must be evaluated. This is framed in contrast to the use of conventional measurement techniques, which provide single values of the measured quantities unable to offer thorough descriptions of deformation distribution. The review outlines the intensity and articulation of work in this research field to date and its ongoing importance not only in the academy, but also in industrial sectors where composite materials represent a strategic resource for development.

  6. Optical Kerr effect in graphene: Theoretical analysis of the optical heterodyne detection technique

    Science.gov (United States)

    Savostianova, N. A.; Mikhailov, S. A.

    2018-04-01

    Graphene is an atomically thin two-dimensional material demonstrating strong optical nonlinearities, including harmonics generation, four-wave mixing, Kerr, and other nonlinear effects. In this paper we theoretically analyze the optical heterodyne detection (OHD) technique of measuring the optical Kerr effect (OKE) in two-dimensional crystals and show how to relate the quantities measured in such experiments with components of the third-order conductivity tensor σαβ γ δ (3 )(ω1,ω2,ω3) of the two-dimensional crystal. Using results of a recently developed quantum theory of the third-order nonlinear electrodynamic response of graphene, we analyze the frequency, charge carrier density, temperature, and other dependencies of the OHD-OKE response of this material. We compare our results with a recent OHD-OKE experiment in graphene and find good agreement between the theory and experiment.

  7. Experimental comparison of particle interaction measurement techniques using optical traps

    International Nuclear Information System (INIS)

    Koehler, Timothy P.; Grillet, Anne Mary; Brotherton, Christopher M.; Molecke, Ryan A.

    2008-01-01

    Optical tweezers has become a powerful and common tool for sensitive determination of electrostatic interactions between colloidal particles. Recently, two techniques, 'blinking' tweezers and direct force measurements, have become increasingly prevalent in investigations of inter-particle potentials. The 'blinking' tweezers method acquires physical statistics of particle trajectories to determine drift velocities, diffusion coefficients, and ultimately colloidal forces as a function of the center-center separation of two particles. Direct force measurements monitor the position of a particle relative to the center of an optical trap as the separation distance between two continuously trapped particles is gradually decreased. As the particles near each other, the displacement from the trap center for each particle increases proportional to the inter-particle force. Although commonly employed in the investigation of interactions of colloidal particles, there exists no direct comparison of these experimental methods in the literature. In this study, an experimental apparatus was developed capable of performing both methods and is used to quantify electrostatic potentials between particles in several particle/solvent systems. Comparisons are drawn between the experiments conducted using the two measurement techniques, theory, and existing literature. Forces are quantified on the femto-Newton scale and results agree well with literature values

  8. Spectroscopic properties of a self-assembled zinc porphyrin tetramer I. Steady state optical spectroscopy

    NARCIS (Netherlands)

    Yatskou, M.M.; Koehorst, R.B.M.; Donker, H.; Schaafsma, T.J.

    2001-01-01

    Aggregation of zinc mono-(4-pyridyl)-triphenylporphyrin (ZnPyP) in toluene and polystyrene/toluene mixtures has been investigated by steady-state optical spectroscopy. The Q-band absorption spectra, as well as the fluorescence spectra, show a temperature-dependent red shift as a result of ligation

  9. Optical band gap and spectroscopic study of lithium alumino silicate glass containing Y3+ ions.

    Science.gov (United States)

    Shakeri, M S; Rezvani, M

    2011-09-01

    The effect of different amounts of Y2O3 dopant on lithium alumino silicate (LAS) glass has been studied in this work. Glasses having 14.8Li2O-20Al2O3-65.2SiO2 (wt%) composition accompanied with Y2O3 dopant were prepared by normal melting process. In order to calculate the absorption coefficient of samples, transmittance and reflectance spectra of polished samples were measured in the room temperature. Optical properties i.e. Fermi energy level, direct and indirect optical band gaps and Urbach energy were calculated using functionality of extinction coefficient from Fermi-Dirac distribution function, Tauc's plot and the exponential part of absorption coefficient diagram, respectively. It has been clarified that variation in mentioned optical parameters is associated with the changes in physical properties of samples i.e. density or molar mass. On the other hand, increasing of Y3+ ions in the glassy microstructure of samples provides a semiconducting character to LAS glass by reducing the direct and indirect optical band gaps of glass samples from 1.97 to 1.67 and 3.46 to 2.1 (eV), respectively. These changes could be attributed to the role of Y3+ ions as the network former in the track of SiO4 tetrahedrals. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Fringe biasing: A variance reduction technique for optically thick meshes

    Energy Technology Data Exchange (ETDEWEB)

    Smedley-Stevenson, R. P. [AWE PLC, Aldermaston Reading, Berkshire, RG7 4PR (United Kingdom)

    2013-07-01

    Fringe biasing is a stratified sampling scheme applicable to Monte Carlo thermal radiation transport codes. The thermal emission source in optically thick cells is partitioned into separate contributions from the cell interiors (where the likelihood of the particles escaping the cells is virtually zero) and the 'fringe' regions close to the cell boundaries. Thermal emission in the cell interiors can now be modelled with fewer particles, the remaining particles being concentrated in the fringes so that they are more likely to contribute to the energy exchange between cells. Unlike other techniques for improving the efficiency in optically thick regions (such as random walk and discrete diffusion treatments), fringe biasing has the benefit of simplicity, as the associated changes are restricted to the sourcing routines with the particle tracking routines being unaffected. This paper presents an analysis of the potential for variance reduction achieved from employing the fringe biasing technique. The aim of this analysis is to guide the implementation of this technique in Monte Carlo thermal radiation codes, specifically in order to aid the choice of the fringe width and the proportion of particles allocated to the fringe (which are interrelated) in multi-dimensional simulations, and to confirm that the significant levels of variance reduction achieved in simulations can be understood by studying the behaviour for simple test cases. The variance reduction properties are studied for a single cell in a slab geometry purely absorbing medium, investigating the accuracy of the scalar flux and current tallies on one of the interfaces with the surrounding medium. (authors)

  11. Fringe biasing: A variance reduction technique for optically thick meshes

    International Nuclear Information System (INIS)

    Smedley-Stevenson, R. P.

    2013-01-01

    Fringe biasing is a stratified sampling scheme applicable to Monte Carlo thermal radiation transport codes. The thermal emission source in optically thick cells is partitioned into separate contributions from the cell interiors (where the likelihood of the particles escaping the cells is virtually zero) and the 'fringe' regions close to the cell boundaries. Thermal emission in the cell interiors can now be modelled with fewer particles, the remaining particles being concentrated in the fringes so that they are more likely to contribute to the energy exchange between cells. Unlike other techniques for improving the efficiency in optically thick regions (such as random walk and discrete diffusion treatments), fringe biasing has the benefit of simplicity, as the associated changes are restricted to the sourcing routines with the particle tracking routines being unaffected. This paper presents an analysis of the potential for variance reduction achieved from employing the fringe biasing technique. The aim of this analysis is to guide the implementation of this technique in Monte Carlo thermal radiation codes, specifically in order to aid the choice of the fringe width and the proportion of particles allocated to the fringe (which are interrelated) in multi-dimensional simulations, and to confirm that the significant levels of variance reduction achieved in simulations can be understood by studying the behaviour for simple test cases. The variance reduction properties are studied for a single cell in a slab geometry purely absorbing medium, investigating the accuracy of the scalar flux and current tallies on one of the interfaces with the surrounding medium. (authors)

  12. Advanced techniques for high resolution spectroscopic observations of cosmic gamma-ray sources

    International Nuclear Information System (INIS)

    Matteson, J.L.; Pelling, M.R.; Peterson, L.E.

    1985-08-01

    We describe an advanced gamma-ray spectrometer that is currently in development. It will obtain a sensitivity of -4 ph/cm -2 -sec in a 6 hour balloon observation and uses innovative techniques for background reduction and source imaging

  13. Vibrational spectroscopic and non-linear optical activity studies on nicotinanilide : A DFT approach

    Science.gov (United States)

    Premkumar, S.; Jawahar, A.; Mathavan, T.; Dhas, M. Kumara; Benial, A. Milton Franklin

    2015-06-01

    The molecular structure of nicotinanilide was optimized by the DFT/B3LYP method with cc-pVTZ basis set using Gaussian 09 program. The first order hyperpolarizability of the molecule was calculated, which exhibits the higher nonlinear optical activity. The natural bond orbital analysis confirms the presence of intramolecular charge transfer and the hydrogen bonding interaction, which leads to the higher nonlinear optical activity of the molecule. The Frontier molecular orbitals analysis of the molecule shows that the delocalization of electron density occurs within the molecule. The lower energy gap indicates that the hydrogen bond formation between the charged species. The vibrational frequencies were calculated and assigned on the basis of potential energy distribution calculation using the VEDA 4.0 program and the corresponding vibrational spectra were simulated. Hence, the nicotinanilide molecule can be a good candidate for second-order NLO material.

  14. HAIFA: A modular, fiber-optic coupled, spectroscopic diagnostic for plasmas

    International Nuclear Information System (INIS)

    Ramsey, A.T.; Turner, S.L.

    1987-01-01

    HAIFA is a modular, multichannel, fiber optically coupled spectroscopy diagnostic for tokamak plasmas. It operates in the visible, measuring H/sub α/ radiation, the visible continuum from thermal bremsstrahlung, and selected impurity lines. HAIFA is characterized by high modularity and flexibility, good radiation resistance, high noise immunity, and low cost. Details of design, construction, and calibration are given. The analysis of visible bremsstrahlung radiation measurements to deduce the effective ionic charge in a plasma is discussed

  15. An optical spectroscopic study of T Tauri stars. I. Photospheric properties

    Energy Technology Data Exchange (ETDEWEB)

    Herczeg, Gregory J. [Kavli Institute for Astronomy and Astrophysics, Peking University, Yi He Yuan Lu 5, Haidian Qu, Beijing 100871 (China); Hillenbrand, Lynne A. [Caltech, MC105-24, 1200 East California Boulevard, Pasadena, CA 91125 (United States)

    2014-05-10

    Estimates of the mass and age of young stars from their location in the H-R diagram are limited by not only the typical observational uncertainties that apply to field stars, but also by large systematic uncertainties related to circumstellar phenomena. In this paper, we analyze flux-calibrated optical spectra to measure accurate spectral types and extinctions of 281 nearby T Tauri stars (TTSs). The primary advances in this paper are (1) the incorporation of a simplistic accretion continuum in optical spectral type and extinction measurements calculated over the full optical wavelength range and (2) the uniform analysis of a large sample of stars, many of which are well known and can serve as benchmarks. Comparisons between the non-accreting TTS photospheric templates and stellar photosphere models are used to derive conversions from spectral type to temperature. Differences between spectral types can be subtle and difficult to discern, especially when accounting for accretion and extinction. The spectral types measured here are mostly consistent with spectral types measured over the past decade. However, our new spectral types are one to two subclasses later than literature spectral types for the original members of the TW Hya Association (TWA) and are discrepant with literature values for some well-known members of the Taurus Molecular Cloud. Our extinction measurements are consistent with other optical extinction measurements but are typically 1 mag lower than near-IR measurements, likely the result of methodological differences and the presence of near-IR excesses in most CTTSs. As an illustration of the impact of accretion, spectral type, and extinction uncertainties on the H-R diagrams of young clusters, we find that the resulting luminosity spread of stars in the TWA is 15%-30%. The luminosity spread in the TWA and previously measured for binary stars in Taurus suggests that for a majority of stars, protostellar accretion rates are not large enough to

  16. EPR and optical spectroscopic studies of neutral free radicals in an adamantane matrix

    International Nuclear Information System (INIS)

    Jordan, J.E.

    1975-03-01

    Recent work in our laboratory has demonstrated that neutral free radicals produced by x-irradiation and trapped in adamantane exhibit exceedingly long lifetimes because of the lack of rapid diffusion in the solid matrix. This observation and the fact that samples can be pressed into pellets with high optical transparency in the visible and near uv regions of the spectrum suggested to us that this unique matrix might be used for studying the optical properties of free radicals. The results of a wide variety of experiments of this type are described in this thesis. These include experiments in which secondary free radicals are produced by photoinduced decomposition of primary free radicals by selective irradiation with visible light, the observation of strong optical absorption spectra of free radicals at room temperature using a Cary 14 spectrophotometer, the finding that certain free radicals exhibit strong, visible fluorescence when irradiated with uv light, and the discovery that the absorption intensity of multiplicity-forbidden transition in singlet and doublet state species is enhanced relative to spin-allowed transitions by at least three orders of magnitude. An analysis of these results in terms of molecular orbital theory is given, and experiments designed to obtain the epr spectra of electronically-excited states of free radicals are described

  17. The Pleiades Using Astronomical Spectroscopic Technique within the Range of H-α Region

    International Nuclear Information System (INIS)

    Zambri Zainuddin, Mohd; Muhyidin, Meer Ashwinkumar; Ahmad, Nazhatulshima; Mohd Saadon, Mohd Hafiz

    2011-01-01

    The Pleiades is an open star cluster located in the constellation of Taurus, which mainly consists of hot and luminous B-type stars. Observations were conducted over five-day period in December 2009 at Langkawi National Observatory, Malaysia by using 20-inch telescope diameter of Ritchey-Chretien reflector telescope, together with SBIG Self Guided Spectrograph and SBIG ST-7 CCD camera. The spectra of seven main members of the cluster, namely Alcyone; Atlas; Celaeno; Electra; Maia; Merope and Taygeta; and of Alcyone B; a smaller component of Alcyone quadruple system, were obtained in the optical range of approximately 6300 A to 7100 A. This range was picked due to the vicinity of Balmer H-α spectral line at 6562.852 A. Alcyone, Electra and Merope were found to have H-α emissions possibly caused by the presence of equatorial circumstellar disks or envelopes made up of ejected matter. Electra and Merope in particular exhibited peculiar asymmetric double emission peaks, which could be evidence of one-armed density wave in each of their circumstellar disks. Atlas, Celaeno, Merope, Taygeta and Alcyone B showed strong H-α absorptions with broadening characteristic of high rotational velocities. As deduced from the spectra, the stars were found to have atmospheres with similar chemical content, with spectral lines characteristics of singly ionized silicon, singly ionized iron and singly ionized oxygen. The measured radial velocities of all eight stars also suggest that the cluster could someday disperse.

  18. Development and applications of laser spectroscopic techniques related to combustion diagnostics

    International Nuclear Information System (INIS)

    Alden, Marcus

    2006-01-01

    Thanks to features as non-intrusiveness combined with high spatial and temporal resolution, various laser diagnostic techniques have during the last decades become of utmost importance for characterization of combustion related phenomena. In the following presentation some further development of the techniques will be highlighted aiming at a) surface temperatures using Thermographic Phosphors, TP, b) species specific, spatially and temporally resolved detection of species absorbing in the IR spectral region using polarization spectroscopy and Laser-induced fluorescence, and finally c) high speed visualization using a special designed laser system in combination with a framing camera. In terms of surface thermometry, Thermographic Phosphors have been used for many years for temperature measurements on solid surfaces. We have during the last years further developed and applied this technique for temperature measurements on burning surfaces and on materials going through phase shifts, e.g. pyrolysis and droplets. The basic principle behind this technique is to apply micron size particles to the surface of interest. By exciting the TP with a short pulse UV laser (ns), the phosphorescence will exhibit a behaviour where the spectral emission as well as the temporal decay are dependent on the temperature. It is thus possible to measure the temperature both in one and two dimensions. The presentation will include basic description of the technique as well as various applications, e.g in fire science, IC engines and gasturbines. Several of the species of interest for combustion/flow diagnostics exhibit a molecular structure which inhibits the use of conventional laser-induced fluorescence for spatially and spectrally resolved measurements. We have during the last years investigated the use of excitation and detection in the infrared region of the spectrum. Here, it is possible to detect both carbonmono/dioxide, water as well as species specific hydrocarbons. The techniques

  19. Algebraic reconstruction techniques for spectral reconstruction in diffuse optical tomography

    International Nuclear Information System (INIS)

    Brendel, Bernhard; Ziegler, Ronny; Nielsen, Tim

    2008-01-01

    Reconstruction in diffuse optical tomography (DOT) necessitates solving the diffusion equation, which is nonlinear with respect to the parameters that have to be reconstructed. Currently applied solving methods are based on the linearization of the equation. For spectral three-dimensional reconstruction, the emerging equation system is too large for direct inversion, but the application of iterative methods is feasible. Computational effort and speed of convergence of these iterative methods are crucial since they determine the computation time of the reconstruction. In this paper, the iterative methods algebraic reconstruction technique (ART) and conjugated gradients (CGs) as well as a new modified ART method are investigated for spectral DOT reconstruction. The aim of the modified ART scheme is to speed up the convergence by considering the specific conditions of spectral reconstruction. As a result, it converges much faster to favorable results than conventional ART and CG methods

  20. Atomic and nuclear analytical methods. XRF, Moessbauer, XPS, NAA and ion-beam spectroscopic techniques

    International Nuclear Information System (INIS)

    Verma, H.R.

    2007-01-01

    This book is a blend of analytical methods based on the phenomenon of atomic and nuclear physics. It comprises comprehensive presentations about X-ray Fluorescence (XRF), Moessbauer Spectroscopy (MS), X-ray Photoelectron Spectroscopy (XPS), Neutron- Activation Analysis (NAA), Particle Induced X-ray Emission Analysis (PIXE), Rutherford Backscattering Analysis (RBS), Elastic Recoil Detection (ERD), Nuclear Reaction Analysis (NRA), Particle Induced Gamma-ray Emission Analysis (PIGE), and Accelerator Mass Spectrometry (AMS). These techniques are commonly applied in the fields of medicine, biology, environmental studies, archaeology or geology et al. and pursued in major international research laboratories. (orig.)

  1. Study of poli (ethylene tereftalate) thin films submitted to radiations by using permeation and spectroscopic techniques

    International Nuclear Information System (INIS)

    Andrade, L.A.

    1986-06-01

    Properties of poly (ethylene terephthalate P.E.T. thin films submitted to electric discharges, electron, He + ion and proton beams were investigated using permeation technique, electronic paramagnetic resonance resonance (E.P.R.) and visible and infrared spectroscopies. Experimental apparatuses and procedures are described and the results of the analyses are presented and discussed. The existence of structural modifications in irradiated P.E.T. thin films is confirmed. It is shown that the kind of effects occuring in irradiated P.E.T. depends on the nature of the incident radiation. (author) [pt

  2. Use of spectroscopic techniques for the chemical analysis of biomorphic silicon carbide ceramics

    International Nuclear Information System (INIS)

    Pavon, J.M. Cano; Alonso, E. Vereda; Cordero, M.T. Siles; Torres, A. Garcia de; Lopez-Cepero, J.M.

    2005-01-01

    Biomorphic silicon carbide ceramics are a new class of materials prepared by several complex processing steps including pre-processing (shaping, drying, high-temperature pyrolysis in an inert atmosphere) and reaction with liquid silicon to obtain silicon-carbide. The results of industrial process of synthesis (measured by the SiC content) must be evaluated by means of fast analytical methods. In the present work, diverse samples of biomorphic ceramics derived from wood are studied for to evaluate the capability of the different analytical techniques (XPS, LIBS, FT-IR and also atomic spectroscopy applied to previously dissolved samples) for the analysis of these materials. XPS and LIBS gives information about the major components, whereas XPS and FT-IR can be used to evaluate the content of SiC. On the other hand, .the use of atomic techniques (as ICP-MS and ETA-AAS) is more adequate for the analysis of metal ions, specially at trace level. The properties of ceramics depend decisively of the content of chemical elements. Major components found were C, Si, Al, S, B and Na in all cases. Previous dissolution of the samples was optimised by acid attack in an oven under microwave irradiation

  3. Analysis of the binding interaction in uric acid - Human hemoglobin system by spectroscopic techniques

    Science.gov (United States)

    Makarska-Bialokoz, Magdalena

    2017-05-01

    The binding interaction between human hemoglobin and uric acid has been studied for the first time, by UV-vis absorption and steady-state, synchronous and three-dimensional fluorescence techniques. Characteristic effects observed for human hemoglobin intrinsic fluorescence during interaction with uric acid at neutral pH point at the formation of stacking non-covalent and non-fluorescent complexes. All the calculated parameters, the binding, fluorescence quenching and bimolecular quenching rate constants, as well as Förster resonance energy transfer parameters confirm the existence of static quenching. The results of synchronous fluorescence measurements indicate that the fluorescence quenching of human hemoglobin originates both from Trp and Tyr residues and that the addition of uric acid could significantly hinder the physiological functions of human hemoglobin.

  4. Phase-dependent Photometric and Spectroscopic Characterization of the MASTER-Net Optical Transient J212444.87+321738.3: An Oxygen-rich Mira

    Science.gov (United States)

    Ghosh, Supriyo; Mondal, Soumen; Das, Ramkrishna; Banerjee, D. P. K.; Ashok, N. M.; Hambsch, Franz-Josef; Dutta, Somnath

    2018-05-01

    We describe the time-dependent properties of a new spectroscopically confirmed Mira variable, which was discovered in 2013 as MASTER-Net Optical Transient J212444.87+321738.3 toward the Cygnus constellation. We have performed long-term optical/near-infrared (NIR) photometric and spectroscopic observations to characterize the object. From the optical/NIR light curves, we estimate a variability period of 465 ± 30 days. The wavelength-dependent amplitudes of the observed light curves range from ΔI ∼ 4 mag to ΔK ∼ 1.5 mag. The (J ‑ K) color index varies from 1.78 to 2.62 mag over phases. Interestingly, a phase lag of ∼60 days between optical and NIR light curves is also seen, as in other Miras. Our optical/NIR spectra show molecular features of TiO, VO, CO, and strong water bands that are a typical signature of oxygen-rich Mira. We rule out S- or C-type as ZrO bands at 1.03 and 1.06 μm and C2 band at 1.77 μm are absent. We estimate the effective temperature of the object from the Spectral Energy Distribution, and distance and luminosity from standard Period–Luminosity relations. The optical/NIR spectra display time-dependent atomic and molecular features (e.g., TiO, Na I, Ca I, H2O, CO), as commonly observed in Miras. Such spectroscopic observations are useful for studying pulsation variability in Miras.

  5. Investigation of HIV-1 infected and uninfected cells using the optical trapping technique

    CSIR Research Space (South Africa)

    Ombinda-Lemboumba, Saturnin

    2017-02-01

    Full Text Available Optical trapping has emerged as an essential tool for manipulating single biological material and performing sophisticated spectroscopy analysis on individual cell. The optical trapping technique has been used to grab and immobilize cells from a...

  6. Gas-phase spectroscopic studies of heavy elements compounds (group V) using FTIR technique

    International Nuclear Information System (INIS)

    Allaf, A. W.; Ajji, Z.

    1998-12-01

    Antimony oxide trihalide, OSbX3 where X=F, CI and Br, and antimony (III) oxychloride, OSbC1 molecules were produced by an on-line process for the first time using antimony chloride SbC13 passed over heated silver oxide then followed by passing the obtained products over heated NaF and heated KBr for SbOF3 and OSbBr3, respectively. The obtained OSbC13 reacts with heated silver to produce OSbC1. The products have been characterized by the infrared spectra of their vapors. The low resolution gas-phase Fourier transform infrared spectrum, reported for the first time, shows the most characteristic band of OSbX3 at 1272, 1217 and 1200 cm -1 and the bands are assigned to the O=Sb stretching fundamental of OSbX3 were X=F, Cl and Br, respectively. The band at 1200 cm -1 needs more experimental investigation. The band at 924 cm -1 is assigned to the O=Sb stretching fundamental of OSbCl molecule. This result is in consistent with expectation and shifted to lower frequency in comparison with arsenic analogous molecule which is investigated by matrix-isolation technique. The work will be continued in order to cover the bismuth and arsenic compounds of similar structures. (author)

  7. Study of DNA interactions with bifenthrin by spectroscopic techniques and molecular modeling

    Science.gov (United States)

    Zhu, Pan; Zhang, Guowen; Ma, Yadi; Zhang, Yepeng; Miao, Hong; Wu, Yongning

    2013-08-01

    The interaction between bifenthrin (BF) and calf thymus DNA (ctDNA) in physiological buffer (pH 7.4) was investigated by UV-vis absorption, fluorescence, circular dichroism (CD), and Fourier transform infrared (FT-IR) spectroscopy, coupled with viscosity measurements and molecular docking techniques. It was found that BF molecular could intercalate into the base pairs of ctDNA as evidenced by significant increases in absorption intensity, fluorescence polarization and relative viscosity of ctDNA, decrease in iodide quenching effect, and induced CD spectral changes. The association constant of BF with ctDNA was evaluated to be in the order of 104 L mol-1. Thermodynamic analysis of the binding data obtained at different temperatures suggested that the binding process was primarily driven by hydrogen bonds and van der Waals forces, as the values of the enthalpy change (ΔH) and the entropy change (ΔS) were calculated to be -31.13 ± 1.89 kJ mol-1 and -22.79 ± 1.21 J mol-1 K-1, respectively. The results of FT-IR spectra and molecular docking showed that a specific binding mainly existed between BF and adenine and guanine bases.

  8. Exploration of disulfiram dealings with calf thymus DNA using spectroscopic, electrochemical and molecular docking techniques

    International Nuclear Information System (INIS)

    Subastri, A.; Durga, A.; Harikrishna, K.; Sureshkumar, M.; Jeevaratnam, K.; Girish, K.S.; Thirunavukkarasu, C.

    2016-01-01

    Disulfiram (C 10 H 20 N 2 S 4 ) is an acetaldehyde dehydrogenase inhibitor used in the treatment of chronic alcoholism and it has also been subjected to the clinical trial for cancer in recent times. However, there is no report on the binding effect of this emerging drug with DNA. Hence, the present investigation was taken up to study the binding effect of disulfiram on DNA under physiological conditions. UV–vis absorption spectroscopy, fluorescence emission spectroscopy, circular dichroism spectroscopy, cyclic voltammetry and molecular docking techniques were employed to determine the interaction mode of disulfiram with DNA. Further, DNA cleavage property of disulfiram was carried out by using agarose gel electrophoresis. The UV–vis absorption, emission and cyclic voltammetry measurements revealed that disulfiram showed the intercalative mode of interaction with DNA. The circular dichroism study exhibited structural changes of partial transition from B-conformation to A-conformation in DNA upon addition of disulfiram. Molecular docking study of disulfiram with DNA depicted intercalative mode of binding by formation of hydrogen and hydrophobic interaction along with docking score of −3.07 kcal/mol. The DNA cleavage study revealed that low concentration of disulfiram (50 µM) protected the DNA from oxidative damage sequentially, while high concentration of disulfiram (100 µM) showed less protective activity. Conversely, it caused DNA damage in the presence of hydroxyl radical oxidative system. Hence, the results obtained from the present investigations provide detailed discernment into DNA interaction effects of disulfiram.

  9. Interaction of an antiepileptic drug, lamotrigine with human serum albumin (HSA): Application of spectroscopic techniques and molecular modeling methods.

    Science.gov (United States)

    Poureshghi, Fatemeh; Ghandforoushan, Parisa; Safarnejad, Azam; Soltani, Somaieh

    2017-01-01

    Lamotrigine (an epileptic drug) interaction with human serum albumin (HSA) was investigated by fluorescence, UV-Vis, FTIR, CD spectroscopic techniques, and molecular modeling methods. Binding constant (K b ) of 5.74×10 3 and number of binding site of 0.97 showed that there is a slight interaction between lamotrigine and HSA. Thermodynamic studies was constructed using the flourimetric titrations in three different temperatures and the resulted data used to calculate the parameters using Vant Hoff equation. Decreased Stern Volmer quenching constant by enhanced temperature revealed the static quenching mechanism. Negative standard enthalpy (ΔH) and standard entropy (ΔS) changes indicated that van der Waals interactions and hydrogen bonds were dominant forces which facilitate the binding of Lamotrigine to HSA, the results were confirmed by molecular docking studies which showed no hydrogen binding. The FRET studies showed that there is a possibility of energy transfer between Trp214 and lamotrigine. Also the binding of lamotrigine to HSA in the studied concentrations was not as much as many other drugs, but the secondary structure of the HSA was significantly changed following the interaction in a way that α-helix percentage was reduced from 67% to 57% after the addition of lamotrigine in the molar ratio of 4:1 to HSA. According to the docking studies, lamotrigine binds to IB site preferably. Copyright © 2016. Published by Elsevier B.V.

  10. Qualitative and quantitative changes in phospholipids and proteins investigated by spectroscopic techniques in olfactory bulbectomy animal depression model.

    Science.gov (United States)

    Depciuch, J; Parlinska-Wojtan, M

    2018-01-30

    Depression becomes nowadays a high mortality civilization disease with one of the potential causes being impaired smell. In this study Raman, Fourier Transform Infra Red (FTIR) and Ultraviolet-Visible (UV-vis) spectroscopies were used to determine the changes in the quantity and structure of phospholipids and proteins in the blood serum of bulbectomized rats (OB_NaCl), which is a common animal depression model. The efficiency of amitriptyline (AMI) treatment was also evaluated. The obtained results show a significant decrease in the phospholipid and protein fractions (as well as changes in their secondary structures) in blood serum of bulbectomized rats. AMI treatment in bulbectomized rats increased protein level and did not affect the level of phospholipids. Structural information from phospholipids and proteins was obtained from UV-vis spectroscopy combined with the second derivative of the FTIR spectra. Indeed, the structure of proteins in blood serum of bulbectomized rats was normalized after amitriptyline therapy, while the damaged structure of phospholipids remained unaffected. These findings strongly suggest that impaired smell could be one of the causes of depression and may induce permanent (irreversible) damages into the phospholipid structure identified as shortened carbon chains. This study shows a possible new application of spectroscopic techniques in the diagnosis and therapy monitoring of depression. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Nuclear spectroscopic study of the 117In and 77Se using angular correlation technique

    International Nuclear Information System (INIS)

    Zamboni, C.B.

    1981-01-01

    The integral pertubed angular correlation technique has been used to measure the g-factor of the 587 KeV(3/2 - ) state in 117 In. The measurements were made in an external magnetic field of 26 Kg. The 1303-273 KeV gamma cascade in 117 In populated from the beta decay of 117 Cd was utilized for the measurement. The result is g(587 KeV) = -0.233+-0.057. The present result shows the 587 KeV state may not be a simple P 3/2 proton hole state but rather a complex admixture of different configurations. The g-factor of the 249 KeV state in 77 Se has also been measured by the time differential pertubed angular correlation (TDPAC) method in an external magnetic field of 25 Kg. The 755-249 KeV gamma cascade in 77 Se populated from the electron capture decay of 57h 77 Br utilized for the measurement. The g-factor is determined to be g(249 KeV) = 0.486 +- 0.009. In addition the half life of the 249 KeV state in 77 Se has also been measured by the delayed gamma-gamma coincidence method utilizing the gamma cascades 572-249 KeV and 750-249 KeV in 77 Se. The resulting value of the half life is T 1/2 (249 KeV) = (9.56 +- 0.10)ns. The experimental results are discussed in terms of nuclear models applicable for nuclei in this mass region. (author) [pt

  12. Exploration of disulfiram dealings with calf thymus DNA using spectroscopic, electrochemical and molecular docking techniques

    Energy Technology Data Exchange (ETDEWEB)

    Subastri, A.; Durga, A. [Department of Biochemistry and Molecular Biology, Pondicherry University, Puducherry 605014 (India); Harikrishna, K.; Sureshkumar, M. [Centre for Bioinformatics, Pondicherry University, Puducherry 605014 (India); Jeevaratnam, K. [Department of Biochemistry and Molecular Biology, Pondicherry University, Puducherry 605014 (India); Girish, K.S. [Department of Studies & Research in Biochemistry, Tumkur University, Tumkur, Karnataka (India); Thirunavukkarasu, C., E-mail: tchinnasamy@hotmail.com [Department of Biochemistry and Molecular Biology, Pondicherry University, Puducherry 605014 (India)

    2016-02-15

    Disulfiram (C{sub 10}H{sub 20}N{sub 2}S{sub 4}) is an acetaldehyde dehydrogenase inhibitor used in the treatment of chronic alcoholism and it has also been subjected to the clinical trial for cancer in recent times. However, there is no report on the binding effect of this emerging drug with DNA. Hence, the present investigation was taken up to study the binding effect of disulfiram on DNA under physiological conditions. UV–vis absorption spectroscopy, fluorescence emission spectroscopy, circular dichroism spectroscopy, cyclic voltammetry and molecular docking techniques were employed to determine the interaction mode of disulfiram with DNA. Further, DNA cleavage property of disulfiram was carried out by using agarose gel electrophoresis. The UV–vis absorption, emission and cyclic voltammetry measurements revealed that disulfiram showed the intercalative mode of interaction with DNA. The circular dichroism study exhibited structural changes of partial transition from B-conformation to A-conformation in DNA upon addition of disulfiram. Molecular docking study of disulfiram with DNA depicted intercalative mode of binding by formation of hydrogen and hydrophobic interaction along with docking score of −3.07 kcal/mol. The DNA cleavage study revealed that low concentration of disulfiram (50 µM) protected the DNA from oxidative damage sequentially, while high concentration of disulfiram (100 µM) showed less protective activity. Conversely, it caused DNA damage in the presence of hydroxyl radical oxidative system. Hence, the results obtained from the present investigations provide detailed discernment into DNA interaction effects of disulfiram.

  13. Vibrational spectroscopic, structural and nonlinear optical activity studies on 6-aminonicotinamide: A DFT approach

    Energy Technology Data Exchange (ETDEWEB)

    Asath, R. Mohamed; Premkumar, S.; Mathavan, T.; Benial, A. Milton Franklin, E-mail: miltonfranklin@yahoo.com [Department of Physics, N.M.S.S.V.N College, Madurai-625019, Tamilnadu (India); Rekha, T. N. [PG & Research Department of Physics, Lady Doak College, Madurai 625002, Tamilnadu (India); Jawahar, A. [Department of Chemistry, N.M.S.S.V.N College, Madurai-625019, Tamilnadu (India)

    2016-05-23

    The conformational analysis was carried out for 6-aminonicotinamide (ANA) using potential energy surface scan method and the most stable optimized conformer was predicted. The theoretical vibrational frequencies were calculated for the optimized geometry using DFT/B3LYP cc-pVQZ basis set by Gaussian 09 Program. The vibrational frequencies were assigned on the basis of potential energy distribution calculation using VEDA 4.0 program. The Mulliken atomic charge values were calculated. In the Frontier molecular orbitals analysis, the molecular reactivity, kinetic stability, intermolecular charge transfer studies and the related molecular properties were calculated. The ultraviolet-visible spectrum was simulated for both in the gas phase and liquid phase (ethanol) and the π to π* electronic transition was predicted. The nonlinear optical (NLO) activity was studied by means of the first order hyperpolarizability value, which was 8.61 times greater than the urea and the natural bond orbital analysis was also performed to confirm the NLO activity of the molecule. Hence, the ANA molecule is a promising candidate for the NLO materials.

  14. Vibrational spectroscopic, structural and nonlinear optical activity studies on 6-aminonicotinamide: A DFT approach

    Science.gov (United States)

    Asath, R. Mohamed; Premkumar, S.; Rekha, T. N.; Jawahar, A.; Mathavan, T.; Benial, A. Milton Franklin

    2016-05-01

    The conformational analysis was carried out for 6-aminonicotinamide (ANA) using potential energy surface scan method and the most stable optimized conformer was predicted. The theoretical vibrational frequencies were calculated for the optimized geometry using DFT/B3LYP cc-pVQZ basis set by Gaussian 09 Program. The vibrational frequencies were assigned on the basis of potential energy distribution calculation using VEDA 4.0 program. The Mulliken atomic charge values were calculated. In the Frontier molecular orbitals analysis, the molecular reactivity, kinetic stability, intermolecular charge transfer studies and the related molecular properties were calculated. The ultraviolet-visible spectrum was simulated for both in the gas phase and liquid phase (ethanol) and the л to л* electronic transition was predicted. The nonlinear optical (NLO) activity was studied by means of the first order hyperpolarizability value, which was 8.61 times greater than the urea and the natural bond orbital analysis was also performed to confirm the NLO activity of the molecule. Hence, the ANA molecule is a promising candidate for the NLO materials.

  15. Analysis of corrosion layers in ancient Roman silver coins with high resolution surface spectroscopic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Keturakis, Christopher J. [Operando Molecular Spectroscopy and Catalysis Research Laboratory, Department of Chemical Engineering, Lehigh University, Bethlehem, PA 18015 (United States); Notis, Ben [Brandeis University, Waltham, MA 02453 (United States); Blenheim, Alex [Department of Mechanical Engineering, Pennsylvania State University, College Park, PA 16802 (United States); Miller, Alfred C.; Pafchek, Rob [Zettlemoyer Center for Surface Studies, Lehigh University, Bethlehem, PA 18015 (United States); Notis, Michael R., E-mail: mrn1@lehigh.edu [Department of Materials Science and Engineering, Lehigh University, Bethlehem, PA 18015 (United States); Wachs, Israel E., E-mail: iew0@lehigh.edu [Operando Molecular Spectroscopy and Catalysis Research Laboratory, Department of Chemical Engineering, Lehigh University, Bethlehem, PA 18015 (United States)

    2016-07-15

    Highlights: • Five ancient silver alloy coins (225 BCE–244 CE) were analyzed using surface characterization techniques. • Both destructive and non-destructive surface characterization methods were developed. • Alloying with copper, even in small amounts, leads to the formation of an outer Cu{sub 2}O corrosion layer. - Abstract: Determination of the microchemistry of surface corrosion layers on ancient silver alloy coins is important both in terms of understanding the nature of archaeological environmental conditions to which these ancient coins were exposed and also to help in their conservation. In this present study, five ancient silver alloy coins (225 BCE–244 CE) were used as test vehicles to measure their immediate surface microchemistry and evaluate the appropriateness and limitations of High Sensitivity-Low Energy Ion Scattering Spectroscopy (HS-LEIS, 0.3 nm depth analysis), High Resolution-X-ray Photoelectron Spectroscopy (HR-XPS, 1–3 nm depth analysis) and High Resolution-Raman Spectroscopy (HR-Raman, ∼1000 nm depth analysis). Additional information about the deeper corrosion layers, up to ∼300–1000 nm, was provided by dynamic HS-LEIS and HR-Raman spectroscopy. While not archeologically significant, the use of these coins of small commercial value provides data that is more representative of the weaker signals typically obtained from ancient corroded objects, which can be in stark contrast to pristine data often obtained from carefully prepared alloys of known composition. The oldest coins, from 225 to 214 BCE, possessed an outermost surface layer containing Cu{sub 2}O, Na, Al, Pb, and adsorbed hydrocarbons, while the more recent coins, from 98 to 244 CE, contained Cu{sub 2}O, Ag, N, F, Na, Al, S, Cl, and adsorbed hydrocarbons in similar corresponding surface layers. It thus appears that alloying with copper, even in small amounts, leads to the formation of an outer Cu{sub 2}O layer. Depth profiling revealed the presence of K, Na, Cl, and

  16. Analysis of corrosion layers in ancient Roman silver coins with high resolution surface spectroscopic techniques

    International Nuclear Information System (INIS)

    Keturakis, Christopher J.; Notis, Ben; Blenheim, Alex; Miller, Alfred C.; Pafchek, Rob; Notis, Michael R.; Wachs, Israel E.

    2016-01-01

    Highlights: • Five ancient silver alloy coins (225 BCE–244 CE) were analyzed using surface characterization techniques. • Both destructive and non-destructive surface characterization methods were developed. • Alloying with copper, even in small amounts, leads to the formation of an outer Cu 2 O corrosion layer. - Abstract: Determination of the microchemistry of surface corrosion layers on ancient silver alloy coins is important both in terms of understanding the nature of archaeological environmental conditions to which these ancient coins were exposed and also to help in their conservation. In this present study, five ancient silver alloy coins (225 BCE–244 CE) were used as test vehicles to measure their immediate surface microchemistry and evaluate the appropriateness and limitations of High Sensitivity-Low Energy Ion Scattering Spectroscopy (HS-LEIS, 0.3 nm depth analysis), High Resolution-X-ray Photoelectron Spectroscopy (HR-XPS, 1–3 nm depth analysis) and High Resolution-Raman Spectroscopy (HR-Raman, ∼1000 nm depth analysis). Additional information about the deeper corrosion layers, up to ∼300–1000 nm, was provided by dynamic HS-LEIS and HR-Raman spectroscopy. While not archeologically significant, the use of these coins of small commercial value provides data that is more representative of the weaker signals typically obtained from ancient corroded objects, which can be in stark contrast to pristine data often obtained from carefully prepared alloys of known composition. The oldest coins, from 225 to 214 BCE, possessed an outermost surface layer containing Cu 2 O, Na, Al, Pb, and adsorbed hydrocarbons, while the more recent coins, from 98 to 244 CE, contained Cu 2 O, Ag, N, F, Na, Al, S, Cl, and adsorbed hydrocarbons in similar corresponding surface layers. It thus appears that alloying with copper, even in small amounts, leads to the formation of an outer Cu 2 O layer. Depth profiling revealed the presence of K, Na, Cl, and S as key

  17. Investigation of the interaction of high intensity laser light with solids and hot plasma using X-ray spectroscopic technique

    International Nuclear Information System (INIS)

    Zigler, A.

    1978-06-01

    This work investigates the properties of high power laser-produced plasmas by developing and applying x-ray spectroscopic methods which utilize spatial resolution. The shadow techniques which were developed in this work yield a high spatial resolution of 5-15μm together with an adequate X-ray spectral resolution for single shots of laser power flux of 2.10 13 W/cm -2 . The intensity distribution in the source is calculated from the partial shadow by numerical differentiation. The main advantage of the present method is the ability to obtain spatial information simultaneously for strong and weak spectral lines for a single shot of medium power laser. Plasma parameters were derived from H-like and He-like lines and their inner-shell satellites, which were obtained from Mg, Al and Si targets. Using shadow techniques, the sizes of the emitting regions of the various spectral lines were measured; the spatial variation of the ionization stage, the electron temperature and density were investigated. A constant electron temperature of (250+-50)eV and electron density scale-length of about 50μm were derived for an expanding plasma. An experimental investigation of the possible origin and the mechanisms responsible for the Ksub(α) radiation in laser-produced plasma was carried out. It is shown that the Ksub(α) radiation was generated by fast suprathermal electrons and originated inside the target behind the interaction zone of the shock and heat waves. Energy penetration depth and hot plasma expansion were tested by using multilayer targets, thin foils and achieving a two-dimensional spatially resolved X-ray Al spectrum. (B.G.)

  18. Synthesis, crystal structure, spectroscopic characterization and nonlinear optical properties of Co(II)- picolinate complex

    Energy Technology Data Exchange (ETDEWEB)

    Tamer, Ömer, E-mail: omertamer@sakarya.edu.tr; Avcı, Davut; Atalay, Yusuf

    2015-11-15

    A cobalt(II) complex of picolinate was synthesized, and its structure was fully characterized by the applying of X-ray diffraction method as well as FT-IR, FT-Raman and UV–vis spectroscopies. In order to both support the experimental results and convert study to more advanced level, density functional theory calculations were performed by using B3LYP level. Single crystal X-ray structural analysis shows that cobalt(II) ion was located to the center of distorted octahedral geometry. The C=O, C=C and C=N stretching vibrations were found as highly active and strong peaks, inducing the molecular charge transfer within Co(II) complex. The small energy gap between frontier molecular orbital energies was another indicator of molecular charge transfer interactions within Co(II) complex. The nonlinear optical properties of Co(II) complex were investigated at DFT/B3LYP level, and the hypepolarizability parameter was found to be decreased due to the presence of inversion symmetry. The natural bond orbital (NBO) analysis was performed to investigate molecular stability, hyperconjugative interactions, intramolecular charge transfer (ICT) and bond strength for Co(II) complex. Finally, molecular electrostatic potential (MEP) and spin density distributions for Co(II) complex were evaluated. - Highlights: • Co(II) complex of picolinate was prepared. • Its FT-IR, FT-Raman and UV–vis spectra were measured. • DFT calculations were performed to support experimental results. • Small HOMO-LUMO energy gap is an indicator of molecular charge transfer. • Spin density localized on Co(II) as well as O and N atoms.

  19. Spectroscopic Determination of the Physical Conditions in Hot Optically Thin Sources

    Science.gov (United States)

    Oliversen, Ronald J. (Technical Monitor); Brickhouse, Nancy

    2004-01-01

    Astrophysical Plasma Emission Database - APED consists of atomic data, primarily theoretical, needed to calculate X-ray through optical emission spectra of hot thermal plasmas. These data are supplemented by experimental values, such as laboratory plasma wave- lengths, and are validated by experiment only rarely. Thus the comparison of predicted spectra to astrophysical spectra serves as invaluable feedback on the quality of the models. Following up on unfavorable comparisons, we have communicated atomic data needs to atomic theorists and experimental plasma physicists so that improvements can be made to the database. The database is now reasonably complete from approx. 1 to 30 A, and from - 90 to 180 A, with significant gaps remaining in the range 30 to 90 A. Astrophysical Plasma Emission Code - APEC uses the APED data as inputs and computes level populations and line emissivities using a rate matrix solver. Tabulated models for a fine grid of temperatures and densities can be applied to observational data. The current public version of APEC output uses an input ionization balance model, assuming CIE; however, we have a working version to calculate the ionization state of the gas. We will begin testing non-equilibrium ionization (NEI) models over the next year - we are now finalizing the atomic database needed to perform the ionization state calculations. At that time, the code will be made public. We have developed optimized error codes, additional testing protocols and substantial documentation, in preparation for this public release. Secondarily, we have begun to investigate the use of APED and APEC for X-ray photoionized plasma, beginning with opacity modeling (e.g. warm absorbers). Application to bright AGN Chandra grating spectra suggests that the accurate wavelengths in APED are of great importance to fitting the data. We are exploring additional subroutines to APEC to extend its usefulness for X-ray photoionized plasma, e.g. to include collisional or photo

  20. Murillo's paintings revealed by spectroscopic techniques and dedicated laboratory-made micro X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Duran, A., E-mail: adrian@icmse.csic.es [Materials Science Institute of Seville, Avda Americo Vespucio 49, 41092 Seville (Spain); Centre de Recherche et de Restauration des Musees de France (C2RMF-CNRS), Palais du Louvre, 14 quai Francois Mitterrand, 75001 Paris (France); Siguenza, M.B.; Franquelo, M.L.; Haro, M.C. Jimenez de; Justo, A.; Perez-Rodriguez, J.L. [Materials Science Institute of Seville, Avda Americo Vespucio 49, 41092 Seville (Spain)

    2010-06-25

    This paper describes one of the first case studies using micro-diffraction laboratory-made systems to analyse painting cross-sections. Pigments, such as lead white, vermilion, red ochre, red lac, lapis lazuli, smalt, lead tin yellow type I, massicot, ivory black, lamp black and malachite, were detected in cross-sections prepared from six Bartolome Esteban Murillo paintings by micro-Raman and micro-XRD combined with complementary techniques (optical microscopy, SEM-EDS, and FT-IR). The use of micro-XRD was necessary due to the poor results obtained with conventional XRD. In some cases, pigment identification was only possible by combining results from the different analytical techniques utilised in this study.

  1. Optical techniques for sensing and measurement in hostile environments

    International Nuclear Information System (INIS)

    Gillespie, C.H.; Greenwell, R.A.

    1987-01-01

    These proceedings collect papers on optical sensing and measurement in hostile environments. Topic include: nuclear waste storage facility monitoring, monitoring of nuclear and chemical explosions, exhaust gas monitoring, fiber-optic monitoring, temperature and radiation effects on optical fibers, and interferometers

  2. Advanced Modulation Techniques for High-Performance Computing Optical Interconnects

    DEFF Research Database (Denmark)

    Karinou, Fotini; Borkowski, Robert; Zibar, Darko

    2013-01-01

    We experimentally assess the performance of a 64 × 64 optical switch fabric used for ns-speed optical cell switching in supercomputer optical interconnects. More specifically, we study four alternative modulation formats and detection schemes, namely, 10-Gb/s nonreturn-to-zero differential phase-...

  3. Multi-pass spectroscopic ellipsometry

    International Nuclear Information System (INIS)

    Stehle, Jean-Louis; Samartzis, Peter C.; Stamataki, Katerina; Piel, Jean-Philippe; Katsoprinakis, George E.; Papadakis, Vassilis; Schimowski, Xavier; Rakitzis, T. Peter; Loppinet, Benoit

    2014-01-01

    Spectroscopic ellipsometry is an established technique, particularly useful for thickness measurements of thin films. It measures polarization rotation after a single reflection of a beam of light on the measured substrate at a given incidence angle. In this paper, we report the development of multi-pass spectroscopic ellipsometry where the light beam reflects multiple times on the sample. We have investigated both theoretically and experimentally the effect of sample reflectivity, number of reflections (passes), angles of incidence and detector dynamic range on ellipsometric observables tanΨ and cosΔ. The multiple pass approach provides increased sensitivity to small changes in Ψ and Δ, opening the way for single measurement determination of optical thickness T, refractive index n and absorption coefficient k of thin films, a significant improvement over the existing techniques. Based on our results, we discuss the strengths, the weaknesses and possible applications of this technique. - Highlights: • We present multi-pass spectroscopic ellipsometry (MPSE), a multi-pass approach to ellipsometry. • Different detectors, samples, angles of incidence and number of passes were tested. • N passes improve polarization ratio sensitivity to the power of N. • N reflections improve phase shift sensitivity by a factor of N. • MPSE can significantly improve thickness measurements in thin films

  4. NITROGEN ISOTOPIC RATIO OF COMETARY AMMONIA FROM HIGH-RESOLUTION OPTICAL SPECTROSCOPIC OBSERVATIONS OF C/2014 Q2 (LOVEJOY)

    Energy Technology Data Exchange (ETDEWEB)

    Shinnaka, Yoshiharu [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Kawakita, Hideyo, E-mail: yoshiharu.shinnaka@nao.ac.jp [Koyama Astronomical Observatory, Kyoto Sangyo University, Motoyama, Kamigamo, Kita-Ku, Kyoto 603-8555 (Japan)

    2016-11-01

    The icy materials present in comets provide clues to the origin and evolution of our solar system and planetary systems. High-resolution optical spectroscopic observations of comet C/2014 Q2 (Lovejoy) were performed on 2015 January 11 (at 1.321 au pre-perihelion) with the High Dispersion Spectrograph mounted on the Subaru Telescope on Maunakea, Hawaii. We derive the {sup 14}N/{sup 15}N ratio of NH{sub 2} (126 ± 25), as well as the ortho-to-para abundance ratios (OPRs) of the H{sub 2}O{sup +} ion (2.77 ± 0.24) and NH{sub 2} (3.38 ± 0.07), which correspond to nuclear spin temperatures of >24 K (3 σ lower limit) and 27 ± 2 K, respectively. We also derive the intensity ratio of the green-to-red doublet of forbidden oxygen lines (0.107 ± 0.007). The ammonia in the comet must have formed under low-temperature conditions at ∼10 K or less to reproduce the observed {sup 14}N/{sup 15}N ratio in this molecule if it is assumed that the {sup 15}N-fractionation of ammonia occurred via ion–molecule chemical reactions. However, this temperature is inconsistent with the nuclear spin temperatures of water and ammonia estimated from the OPRs. The interpretation of the nuclear spin temperature as the temperature at molecular formation may therefore be incorrect. An isotope-selective photodissociation of molecular nitrogen by protosolar ultraviolet radiation might play an important role in the {sup 15}N-fractionation observed in cometary volatiles.

  5. THE TIME-DOMAIN SPECTROSCOPIC SURVEY: UNDERSTANDING THE OPTICALLY VARIABLE SKY WITH SEQUELS IN SDSS-III

    Energy Technology Data Exchange (ETDEWEB)

    Ruan, John J.; Anderson, Scott F.; Davenport, James R. A. [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States); Green, Paul J.; Morganson, Eric [Harvard Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Eracleous, Michael; Brandt, William N. [Department of Astronomy and Astrophysics, 525 Davey Lab, The Pennsylvania State University, University Park, PA 16802 (United States); Myers, Adam D. [Department of Physics and Astronomy 3905, University of Wyoming, 1000 E. University, Laramie, WY 82071 (United States); Badenes, Carles [Department of Physics and Astronomy and Pittsburgh Particle Physics, Astrophysics, and Cosmology Center (PITT-PACC), University of Pittsburgh (United States); Bershady, Matthew A. [Department of Astronomy, University of Wisconsin-Madison, 475 N. Charter Street, Madison, WI 53706 (United States); Chambers, Kenneth C.; Flewelling, Heather; Kaiser, Nick [Institute for Astronomy, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); Dawson, Kyle S. [Department of Physics and Astronomy, University of Utah, Salt Lake City, UT 84112 (United States); Heckman, Timothy M. [Center for Astrophysical Sciences, Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD 21218 (United States); Isler, Jedidah C. [Department of Physics and Astronomy, Vanderbilt University, Nashville, TN 37235 (United States); Kneib, Jean-Paul [Laboratoire d’astrophysique, Ecole Polytechnique Fédérale de Lausanne Observatoire de Sauverny, 1290 Versoix (Switzerland); MacLeod, Chelsea L.; Ross, Nicholas P. [Institute for Astronomy, University of Edinburgh, Royal Observatory, Edinburgh, EH9 3HJ (United Kingdom); Paris, Isabelle, E-mail: jruan@astro.washington.edu [INAF—Osservatorio Astronomico di Trieste, Via G. B. Tiepolo 11, I-34131 Trieste (Italy); and others

    2016-07-10

    The Time-Domain Spectroscopic Survey (TDSS) is an SDSS-IV eBOSS subproject primarily aimed at obtaining identification spectra of ∼220,000 optically variable objects systematically selected from SDSS/Pan-STARRS1 multi-epoch imaging. We present a preview of the science enabled by TDSS, based on TDSS spectra taken over ∼320 deg{sup 2} of sky as part of the SEQUELS survey in SDSS-III, which is in part a pilot survey for eBOSS in SDSS-IV. Using the 15,746 TDSS-selected single-epoch spectra of photometrically variable objects in SEQUELS, we determine the demographics of our variability-selected sample and investigate the unique spectral characteristics inherent in samples selected by variability. We show that variability-based selection of quasars complements color-based selection by selecting additional redder quasars and mitigates redshift biases to produce a smooth quasar redshift distribution over a wide range of redshifts. The resulting quasar sample contains systematically higher fractions of blazars and broad absorption line quasars than from color-selected samples. Similarly, we show that M dwarfs in the TDSS-selected stellar sample have systematically higher chromospheric active fractions than the underlying M-dwarf population based on their H α emission. TDSS also contains a large number of RR Lyrae and eclipsing binary stars with main-sequence colors, including a few composite-spectrum binaries. Finally, our visual inspection of TDSS spectra uncovers a significant number of peculiar spectra, and we highlight a few cases of these interesting objects. With a factor of ∼15 more spectra, the main TDSS survey in SDSS-IV will leverage the lessons learned from these early results for a variety of time-domain science applications.

  6. THE TIME-DOMAIN SPECTROSCOPIC SURVEY: UNDERSTANDING THE OPTICALLY VARIABLE SKY WITH SEQUELS IN SDSS-III

    International Nuclear Information System (INIS)

    Ruan, John J.; Anderson, Scott F.; Davenport, James R. A.; Green, Paul J.; Morganson, Eric; Eracleous, Michael; Brandt, William N.; Myers, Adam D.; Badenes, Carles; Bershady, Matthew A.; Chambers, Kenneth C.; Flewelling, Heather; Kaiser, Nick; Dawson, Kyle S.; Heckman, Timothy M.; Isler, Jedidah C.; Kneib, Jean-Paul; MacLeod, Chelsea L.; Ross, Nicholas P.; Paris, Isabelle

    2016-01-01

    The Time-Domain Spectroscopic Survey (TDSS) is an SDSS-IV eBOSS subproject primarily aimed at obtaining identification spectra of ∼220,000 optically variable objects systematically selected from SDSS/Pan-STARRS1 multi-epoch imaging. We present a preview of the science enabled by TDSS, based on TDSS spectra taken over ∼320 deg 2 of sky as part of the SEQUELS survey in SDSS-III, which is in part a pilot survey for eBOSS in SDSS-IV. Using the 15,746 TDSS-selected single-epoch spectra of photometrically variable objects in SEQUELS, we determine the demographics of our variability-selected sample and investigate the unique spectral characteristics inherent in samples selected by variability. We show that variability-based selection of quasars complements color-based selection by selecting additional redder quasars and mitigates redshift biases to produce a smooth quasar redshift distribution over a wide range of redshifts. The resulting quasar sample contains systematically higher fractions of blazars and broad absorption line quasars than from color-selected samples. Similarly, we show that M dwarfs in the TDSS-selected stellar sample have systematically higher chromospheric active fractions than the underlying M-dwarf population based on their H α emission. TDSS also contains a large number of RR Lyrae and eclipsing binary stars with main-sequence colors, including a few composite-spectrum binaries. Finally, our visual inspection of TDSS spectra uncovers a significant number of peculiar spectra, and we highlight a few cases of these interesting objects. With a factor of ∼15 more spectra, the main TDSS survey in SDSS-IV will leverage the lessons learned from these early results for a variety of time-domain science applications.

  7. Online technique for detecting state of onboard fiber optic gyroscope

    International Nuclear Information System (INIS)

    Miao, Zhiyong; He, Kunpeng; Pang, Shuwan; Xu, Dingjie; Tian, Chunmiao

    2015-01-01

    Although angle random walk (ARW) of fiber optic gyroscope (FOG) has been well modeled and identified before being integrated into the high-accuracy attitude control system of satellite, aging and unexpected failures can affect the performance of FOG after launch, resulting in the variation of ARW coefficient. Therefore, the ARW coefficient can be regarded as an indicator of “state of health” for FOG diagnosis in some sense. The Allan variance method can be used to estimate ARW coefficient of FOG, however, it requires a large amount of data to be stored. Moreover, the procedure of drawing slope lines for estimation is painful. To overcome the barriers, a weighted state-space model that directly models the ARW to obtain a nonlinear state-space model was established for FOG. Then, a neural extended-Kalman filter algorithm was implemented to estimate and track the variation of ARW in real time. The results of experiment show that the proposed approach is valid to detect the state of FOG. Moreover, the proposed technique effectively avoids the storage of data

  8. Novel technique for solar power illumination using plastic optical fibres

    Science.gov (United States)

    Munisami, J.; Kalymnios, D.

    2008-09-01

    Plastic Optical Fibres (POF) were developed almost 3 decades ago. They are mainly used for short haul data communications (up to 1 km with data rates up to 1 Gbps). Over the years, POF has found applications in many other areas including solar energy transport for illumination. In such an application, light is collected from the sun and is directed into a space which needs to be illuminated. The use of fibres and more specifically POF, in daylighting systems, started only a few years ago. Several approaches have been investigated and we have seen the development of a few commercial products. The market however, has not really taken off for these technologies simply because of their enormous price tags. It is important to note that the use of POF in these designs has been limited to the function of POF as the transmission medium only. We propose a novel solar illumination technique using POF as both the light collecting/concentrating mechanism and the transmission medium. By modifying the structure of the fibre, solar light can be directed into the fibre by using an analogous process to fibre side emission but, in the reverse. We shall report on the solar light capturing efficiency of POF as modified by several types of external imperfections introduced onto the fibre. One major advantage of our proposed approach lies in the fact that we aim to eliminate at least one of the two axes of sun tracking that is currently used in existing solar illumination systems.

  9. Online technique for detecting state of onboard fiber optic gyroscope

    Energy Technology Data Exchange (ETDEWEB)

    Miao, Zhiyong; He, Kunpeng, E-mail: pengkhe@126.com; Pang, Shuwan [Department of Automation, Harbin Engineering University, Harbin, Heilongjiang 150000 (China); Xu, Dingjie [School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, Heilongjiang 150000 (China); Tian, Chunmiao [Department of Information and Communication Engineering, Harbin Engineering University, Harbin, Heilongjiang 150000 (China)

    2015-02-15

    Although angle random walk (ARW) of fiber optic gyroscope (FOG) has been well modeled and identified before being integrated into the high-accuracy attitude control system of satellite, aging and unexpected failures can affect the performance of FOG after launch, resulting in the variation of ARW coefficient. Therefore, the ARW coefficient can be regarded as an indicator of “state of health” for FOG diagnosis in some sense. The Allan variance method can be used to estimate ARW coefficient of FOG, however, it requires a large amount of data to be stored. Moreover, the procedure of drawing slope lines for estimation is painful. To overcome the barriers, a weighted state-space model that directly models the ARW to obtain a nonlinear state-space model was established for FOG. Then, a neural extended-Kalman filter algorithm was implemented to estimate and track the variation of ARW in real time. The results of experiment show that the proposed approach is valid to detect the state of FOG. Moreover, the proposed technique effectively avoids the storage of data.

  10. New perspectives in hydrodynamic radial polishing techniques for optical surfaces

    Science.gov (United States)

    Ruiz, Elfego; Sohn, Erika; Luna, Esteban; Salas, Luis; Cordero, Alberto; González, Jorge; Núñez, Manuel; Salinas, Javier; Cruz-González, Irene; Valdés, Jorge; Cabrera, Victor; Martínez, Benjamín

    2004-09-01

    In order to overcome classic polishing techniques, a novel hydrodynamic radial polishing tool (HyDRa) is presented; it is useful for the corrective lapping and fine polishing of diverse materials by means of a low-cost abrasive flux and a hydrostatic suspension system that avoids contact of the tool with the working surface. This tool enables the work on flat or curved surfaces of currently up to two and a half meters in diameter. It has the advantage of avoiding fallen edges during the polishing process as well as reducing tool wear out and deformation. The functioning principle is based on the generation of a high-velocity, high-pressure, abrasive emulsion flux with radial geometry. The polishing process is repeatable by means of the control of the tool operational parameters, achieving high degrees of precision and accuracy on optical and semiconductor surfaces, with removal rates of up to 9 mm3/hour and promising excellent surface polishing qualities. An additional advantage of this new tool is the possibility to perform interferometric measurements during the polishing process without the need of dismounting the working surface. A series of advantages of this method, numerical simulations and experimental results are described.

  11. Optical properties of Au–TiO{sub 2} and Au–SiO{sub 2} granular metal thin films studied by Spectroscopic Ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Bakkali, H., E-mail: hicham.bakkali@mail.uca.es [Departamento de Física de la Materia Condensada and Instituto de Microscopía Electrónica y Materiales (IMEYMAT), Universidad de Cadiz, 11510 Puerto Real, Cádiz (Spain); Centro de Ciencias Aplicadas y Desarrollo Tecnológico (CCADET), Universidad Nacional Autónoma de México (UNAM), México, D.F. 04510 (Mexico); Blanco, E.; Dominguez, M. [Departamento de Física de la Materia Condensada and Instituto de Microscopía Electrónica y Materiales (IMEYMAT), Universidad de Cadiz, 11510 Puerto Real, Cádiz (Spain); Mora, M.B. de la [CONACyT Research Fellow-CCADET, Universidad Nacional Autónoma de México (UNAM), México, D.F. 04510 (Mexico); Sánchez-Aké, C.; Villagrán-Muniz, M. [Centro de Ciencias Aplicadas y Desarrollo Tecnológico (CCADET), Universidad Nacional Autónoma de México (UNAM), México, D.F. 04510 (Mexico)

    2017-05-31

    Highlights: • Gold NPs embedded in TiO{sub 2} or SiO{sub 2} are fabricated by single RF magnetron sputtering. • Films thickness and optical constants are determined by Spectroscopic Ellipsometry. - Abstract: We report on the optical properties in the dielectric regime of gold nanostructured granular thin films fabricated through sputter deposition with a composite target at room temperature and over a wide photon energy range (0.62–4.13 eV) by means of Spectroscopic Ellipsometry. The thickness and the films effective optical constants are successfully determined using an approach based on multiple Gaussian oscillators. In the quasi-static regime, i.e., 2R ≪ λ, and in the dipole approximation, examining the real and imaginary parts, ε{sub 1}, ε{sub 2}, of the dielectric function, it is shown that the dc optical conductivity is almost negligible (σ = ωε{sub 0}ε{sub 2} ≪ 10{sup −5} Ω cm{sup −1}) and only the capacitive contribution holds for the electron-phonon relaxation in localized surface plasmon of the gold particles. Furthermore, we find that the resonant frequencies ω{sub p} becomes red-shifted when the particles are electromagnetically coupled to each other or when the surrounding medium dielectric constant, ε{sub m}, increases, thus exhibiting a wide spectral tuning range of 1.95–2.24 eV.

  12. Spectroscopic data

    CERN Document Server

    Melzer, J

    1976-01-01

    During the preparation of this compilation, many people contributed; the compilers wish to thank all of them. In particular they appreciate the efforts of V. Gilbertson, the manuscript typist, and those of K. C. Bregand, J. A. Kiley, and W. H. McPherson, who gave editorial assistance. They would like to thank Dr. J. R. Schwartz for his cooperation and encouragement. In addition, they extend their grati­ tude to Dr. L. Wilson of the Air Force Weapons Laboratory, who gave the initial impetus to this project. v Contents I. I ntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . 11. Organization ofthe Spectroscopic Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Methods of Production and Experimental Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Band Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2...

  13. Optimization of coronary optical coherence tomography imaging using the attenuation-compensated technique: a validation study.

    NARCIS (Netherlands)

    Teo, Jing Chun; Foin, Nicolas; Otsuka, Fumiyuki; Bulluck, Heerajnarain; Fam, Jiang Ming; Wong, Philip; Low, Fatt Hoe; Leo, Hwa Liang; Mari, Jean-Martial; Joner, Michael; Girard, Michael J A; Virmani, Renu; Bezerra, HG.; Costa, MA.; Guagliumi, G.; Rollins, AM.; Simon, D.; Gutiérrez-Chico, JL.; Alegría-Barrero, E.; Teijeiro-Mestre, R.; Chan, PH.; Tsujioka, H.; de Silva, R.; Otsuka, F.; Joner, M.; Prati, F.; Virmani, R.; Narula, J.; Members, WC.; Levine, GN.; Bates, ER.; Blankenship, JC.; Bailey, SR.; Bittl, JA.; Prati, F.; Guagliumi, G.; Mintz, G.S.; Costa, Marco; Regar, E.; Akasaka, T.; Roleder, T.; Jąkała, J.; Kałuża, GL.; Partyka, Ł.; Proniewska, K.; Pociask, E.; Girard, MJA.; Strouthidis, NG.; Ethier, CR.; Mari, JM.; Mari, JM.; Strouthidis, NG.; Park, SC.; Girard, MJA.; van der Lee, R.; Foin, N.; Otsuka, F.; Wong, P.K.; Mari, J-M.; Joner, M.; Nakano, M.; Vorpahl, M.; Otsuka, F.; Taniwaki, M.; Yazdani, SK.; Finn, AV.; Nakano, M.; Yahagi, K.; Yamamoto, H.; Taniwaki, M.; Otsuka, F.; Ladich, ER.; Girard, MJ.; Ang, M.; Chung, CW.; Farook, M.; Strouthidis, N.; Mehta, JS.; Foin, N.; Mari, JM.; Nijjer, S.; Sen, S.; Petraco, R.; Ghione, M.; Liu, X.; Kang, JU.; Virmani, R.; Kolodgie, F.D.; Burke, AP.; Farb, A.; Schwartz, S.M.; Yahagi, K.; Kolodgie, F.D.; Otsuka, F.; Finn, AV.; Davis, HR.; Joner, M.; Kume, T.; Akasaka, T.; Kawamoto, T.; Watanabe, N.; Toyota, E.; Neishi, Y.; Rieber, J.; Meissner, O.; Babaryka, G.; Reim, S.; Oswald, M.E.; Koenig, A.S.; Tearney, G. J.; Regar, E.; Akasaka, T.; Adriaenssens, T.; Barlis, P.; Bezerra, HG.; Yabushita, H.; Bouma, BE.; Houser, S. L.; Aretz, HT.; Jang, I-K.; Schlendorf, KH.; Guo, J.; Sun, L.; Chen, Y.D.; Tian, F.; Liu, HB.; Chen, L.; Kawasaki, M.; Bouma, BE.; Bressner, J. E.; Houser, S. L.; Nadkarni, S. K.; MacNeill, BD.; Jansen, CHP.; Onthank, DC.; Cuello, F.; Botnar, RM.; Wiethoff, AJ.; Warley, A.; von Birgelen, C.; Hartmann, A. M.; Kubo, T.; Akasaka, T.; Shite, J.; Suzuki, T.; Uemura, S.; Yu, B.; Habara, M.; Nasu, K.; Terashima, M.; Kaneda, H.; Yokota, D.; Ko, E.; Virmani, R.; Burke, AP.; Kolodgie, F.D.; Farb, A.; Takarada, S.; Imanishi, T.; Kubo, T.; Tanimoto, T.; Kitabata, H.; Nakamura, N.; Hattori, K.; Ozaki, Y.; Ismail, TF.; Okumura, M.; Naruse, H.; Kan, S.; Nishio, R.; Shinke, T.; Otake, H.; Nakagawa, M.; Nagoshi, R.; Inoue, T.; Sinclair, H.D.; Bourantas, C.; Bagnall, A.; Mintz, G.S.; Kunadian, V.; Tearney, G. J.; Yabushita, H.; Houser, S. L.; Aretz, HT.; Jang, I-K.; Schlendorf, KH.; van Soest, G.; Goderie, T.; Regar, E.; Koljenović, S.; Leenders, GL. van; Gonzalo, N.; Xu, C.; Schmitt, JM.; Carlier, SG.; Virmani, R.; van der Meer, FJ; Faber, D.J.; Sassoon, DMB.; Aalders, M.C.; Pasterkamp, G.; Leeuwen, TG. van; Schmitt, JM.; Knuttel, A.; Yadlowsky, M.; Eckhaus, MA.; Karamata, B.; Laubscher, M.; Leutenegger, M.; Bourquin, S.; Lasser, T.; Lambelet, P.; Vermeer, K.A.; Mo, J.; Weda, J.J.A.; Lemij, H.G.; Boer, JF. de

    2016-01-01

    PURPOSE To optimize conventional coronary optical coherence tomography (OCT) images using the attenuation-compensated technique to improve identification of plaques and the external elastic lamina (EEL) contour. METHOD The attenuation-compensated technique was optimized via manipulating contrast

  14. Spectroscopic investigations using density functional theory on 2-methoxy- 4(phenyliminomethyl)phenol: A non linear optical material

    Science.gov (United States)

    Hijas, K. M.; Madan Kumar, S.; Byrappa, K.; Geethakrishnan, T.; Jeyaram, S.; Nagalakshmi, R.

    2018-03-01

    Single crystals of 2-methoxy-4(phenyliminomethyl)phenol were grown from ethanol by slow evaporation solution growth technique. Single crystal X-ray diffraction experiment reveals the crystallization in orthorhombic system having non-centrosymmetric space group C2221. Geometrical optimization by density functional theory method was carried out using Gaussian program and compared with experimental results. Detailed experimental and theoretical vibrational analyses were carried out and the results were correlated to find close agreement. Thermal analyses show the material is thermally stable with a melting point of 159 °C. Natural bond orbital analysis was carried out to explain charge transfer interactions through hydrogen bonding. Relatively smaller HOMO-LUMO band gap favors the non linear optical activity of the molecule. Natural population analysis and molecular electrostatic potential calculations visualize the charge distribution in an isolated molecule. Calculated first-order molecular hyperpolarizability and preliminary second harmonic generation test carried out using Kurtz-Perry technique establish 2-methoxy-4(phenyliminomethyl)phenol crystal as a good non linear optical material. Z-scan proposes the material for reverse saturable absorption.

  15. Non-linear optical techniques and optical properties of condensed molecular systems

    Science.gov (United States)

    Citroni, Margherita

    2013-06-01

    Structure, dynamics, and optical properties of molecular systems can be largely modified by the applied pressure, with remarkable consequences on their chemical stability. Several examples of selective reactions yielding technologically attractive products can be cited, which are particularly efficient when photochemical effects are exploited in conjunction with the structural conditions attained at high density. Non-linear optical techniques are a basic tool to unveil key aspects of the chemical reactivity and dynamic properties of molecules. Their application to high-pressure samples is experimentally challenging, mainly because of the small sample dimensions and of the non-linear effects generated in the anvil materials. In this talk I will present results on the electronic spectra of several aromatic crystals obtained through two-photon induced fluorescence and two-photon excitation profiles measured as a function of pressure (typically up to about 25 GPa), and discuss the relationship between the pressure-induced modifications of the electronic structure and the chemical reactivity at high pressure. I will also present the first successful pump-probe infrared measurement performed as a function of pressure on a condensed molecular system. The system under examination is liquid water, in a sapphire anvil cell, up to 1 GPa along isotherms at 298 and 363 K. These measurements give a new enlightening insight into the dynamical properties of low- and high-density water allowing a definition of the two structures.

  16. Measurements of the aerosol chemical composition and mixing state in the Po Valley using multiple spectroscopic techniques

    Science.gov (United States)

    Decesari, S.; Allan, J.; Plass-Duelmer, C.; Williams, B. J.; Paglione, M.; Facchini, M. C.; O'Dowd, C.; Harrison, R. M.; Gietl, J. K.; Coe, H.; Giulianelli, L.; Gobbi, G. P.; Lanconelli, C.; Carbone, C.; Worsnop, D.; Lambe, A. T.; Ahern, A. T.; Moretti, F.; Tagliavini, E.; Elste, T.; Gilge, S.; Zhang, Y.; Dall'Osto, M.

    2014-11-01

    The use of co-located multiple spectroscopic techniques can provide detailed information on the atmospheric processes regulating aerosol chemical composition and mixing state. So far, field campaigns heavily equipped with aerosol mass spectrometers have been carried out mainly in large conurbations and in areas directly affected by their outflow, whereas lesser efforts have been dedicated to continental areas characterised by a less dense urbanisation. We present here the results obtained at a background site in the Po Valley, Italy, in summer 2009. For the first time in Europe, six state-of-the-art spectrometric techniques were used in parallel: aerosol time-of-flight mass spectrometer (ATOFMS), two aerosol mass spectrometers (high-resolution time-of-flight aerosol mass spectrometer - HR-ToF-AMS and soot particle aerosol mass spectrometer - SP-AMS), thermal desorption aerosol gas chromatography (TAG), chemical ionisation mass spectrometry (CIMS) and (offline) proton nuclear magnetic resonance (1H-NMR) spectroscopy. The results indicate that, under high-pressure conditions, atmospheric stratification at night and early morning hours led to the accumulation of aerosols produced by anthropogenic sources distributed over the Po Valley plain. Such aerosols include primary components such as black carbon (BC), secondary semivolatile compounds such as ammonium nitrate and amines and a class of monocarboxylic acids which correspond to the AMS cooking organic aerosol (COA) already identified in urban areas. In daytime, the entrainment of aged air masses in the mixing layer is responsible for the accumulation of low-volatility oxygenated organic aerosol (LV-OOA) and also for the recycling of non-volatile primary species such as black carbon. According to organic aerosol source apportionment, anthropogenic aerosols accumulating in the lower layers overnight accounted for 38% of organic aerosol mass on average, another 21% was accounted for by aerosols recirculated in

  17. Analysis technique for controlling system wavefront error with active/adaptive optics

    Science.gov (United States)

    Genberg, Victor L.; Michels, Gregory J.

    2017-08-01

    The ultimate goal of an active mirror system is to control system level wavefront error (WFE). In the past, the use of this technique was limited by the difficulty of obtaining a linear optics model. In this paper, an automated method for controlling system level WFE using a linear optics model is presented. An error estimate is included in the analysis output for both surface error disturbance fitting and actuator influence function fitting. To control adaptive optics, the technique has been extended to write system WFE in state space matrix form. The technique is demonstrated by example with SigFit, a commercially available tool integrating mechanical analysis with optical analysis.

  18. Turbo Equalization Techniques Toward Robust PDM 16-QAM Optical Fiber Transmission

    DEFF Research Database (Denmark)

    Arlunno, Valeria; Caballero Jambrina, Antonio; Borkowski, Robert

    2014-01-01

    In this paper, we show numerically and experimentally that turbo equalization (TE) is an efficient technique to mitigate performance degradations stemming from optical fiber propagation effects in both optical fiber dispersion managed and unmanaged coherent detection links. The effectiveness....... As TE can be included in the current coherent detection transceiver technologies and complement other equalization techniques, it has prospects for application in next-generation high-capacity and long-reach optical transmission links....

  19. Possibilities for Advanced Encoding Techniques at Signal Transmission in the Optical Transmission Medium

    Directory of Open Access Journals (Sweden)

    Filip Čertík

    2016-01-01

    Full Text Available This paper presents a possible simulation of negative effects in the optical transmission medium and an analysis for the utilization of different signal processing techniques at the optical signal transmission. An attention is focused on the high data rate signal transmission in the optical fiber influenced by linear and nonlinear environmental effects presented by the prepared simulation model. The analysis includes possible utilization of OOK, BPSK, DBPSK, BFSK, QPSK, DQPSK, 8PSK, and 16QAM modulation techniques together with RS, BCH, and LDPC encoding techniques for the signal transmission in the optical fiber. Moreover, the prepared simulation model is compared with real optical transmission systems. In the final part, a comparison of the selected modulation techniques with different encoding techniques and their implementation in real transmission systems is shown.

  20. Spectroscopic study

    International Nuclear Information System (INIS)

    Flores, M.; Rodriguez, R.; Arroyo, R.

    1999-01-01

    This work is focused about the spectroscopic properties of a polymer material which consists of Polyacrylic acid (Paa) doped at different concentrations of Europium ions (Eu 3+ ). They show that to stay chemically joined with the polymer by a study of Nuclear Magnetic Resonance (NMR) of 1 H, 13 C and Fourier Transform Infrared Spectroscopy (Ft-IR) they present changes in the intensity of signals, just as too when this material is irradiated at λ = 394 nm. In according with the results obtained experimentally in this type of materials it can say that is possible to unify chemically the polymer with this type of cations, as well as, varying the concentration of them, since that these are distributed homogeneously inside the matrix maintaining its optical properties. These materials can be obtained more quickly and easy in solid or liquid phase and they have the best conditions for to make a quantitative analysis. (Author)

  1. Astrophysical techniques

    CERN Document Server

    Kitchin, CR

    2013-01-01

    DetectorsOptical DetectionRadio and Microwave DetectionX-Ray and Gamma-Ray DetectionCosmic Ray DetectorsNeutrino DetectorsGravitational Radiation Dark Matter and Dark Energy Detection ImagingThe Inverse ProblemPhotographyElectronic ImagingScanningInterferometrySpeckle InterferometryOccultationsRadarElectronic ImagesPhotometryPhotometryPhotometersSpectroscopySpectroscopy SpectroscopesOther TechniquesAstrometryPolarimetrySolar StudiesMagnetometryComputers and The Internet.

  2. Advanced materials and techniques for fibre-optic sensing

    International Nuclear Information System (INIS)

    Henderson, Philip J

    2014-01-01

    Fibre-optic monitoring systems came of age in about 1999 upon the emergence of the world's first significant commercialising company – a spin-out from the UK's collaborative MAST project. By using embedded fibre-optic technology, the MAST project successfully measured transient strain within high-performance composite yacht masts. Since then, applications have extended from smart composites into civil engineering, energy, military, aerospace, medicine and other sectors. Fibre-optic sensors come in various forms, and may be subject to embedment, retrofitting, and remote interrogation. The unique challenges presented by each implementation require careful scrutiny before widespread adoption can take place. Accordingly, various aspects of design and reliability are discussed spanning a range of representative technologies that include resonant microsilicon structures, MEMS, Bragg gratings, advanced forms of spectroscopy, and modern trends in nanotechnology. Keywords: Fibre-optic sensors, fibre Bragg gratings, MEMS, MOEMS, nanotechnology, plasmon

  3. Advanced materials and techniques for fibre-optic sensing

    Science.gov (United States)

    Henderson, Philip J.

    2014-06-01

    Fibre-optic monitoring systems came of age in about 1999 upon the emergence of the world's first significant commercialising company - a spin-out from the UK's collaborative MAST project. By using embedded fibre-optic technology, the MAST project successfully measured transient strain within high-performance composite yacht masts. Since then, applications have extended from smart composites into civil engineering, energy, military, aerospace, medicine and other sectors. Fibre-optic sensors come in various forms, and may be subject to embedment, retrofitting, and remote interrogation. The unique challenges presented by each implementation require careful scrutiny before widespread adoption can take place. Accordingly, various aspects of design and reliability are discussed spanning a range of representative technologies that include resonant microsilicon structures, MEMS, Bragg gratings, advanced forms of spectroscopy, and modern trends in nanotechnology. Keywords: Fibre-optic sensors, fibre Bragg gratings, MEMS, MOEMS, nanotechnology, plasmon.

  4. Development of optical surface contouring technique using laser

    Energy Technology Data Exchange (ETDEWEB)

    Baik, Sung Hoon; Kim, Min Suk; Park, Seung Kyu

    1998-12-01

    Laser contouring system capable of measuring relief profiles using a line-shaped laser beam with anisotropic magnification optics composed with two cylindrical lenses was developed. The anisotropic magnification optical system allows it to obtain higher resolution in the relief profile measurements. The image processing and 3-D display software are developed to reconstruct 3-D shape. The power supply of laser diode with adaptive current control circuit is designed. (author). 4 refs., 5 tabs., 33 figs.

  5. A study on Optical Labelling Techniques for All-Optical Networks

    DEFF Research Database (Denmark)

    Holm-Nielsen, Pablo Villanueva

    2005-01-01

    Optical switching has been proposed as an effective solution to overcoming the potential electronic bottleneck in all-optical network nodes carrying IP over WDM. The solution builds on the use of optical labelling as a mean to route packets or bursts of packets through the network. In addition...... of an intermediate wavelength between label erasure and label insertion. The above mentioned functionalities are assembled in whole network systems experiments that validates the different labelling schemes with respect to transmission, wavelength conversion, label swapping and retransmission. Optical labelling...... and specially the orthogonal schemes for optical labelling, are thus shown to be an effective solution to all-optical networks....

  6. Optical spectroscopic study of multiferroic BiFeO3 and LuFe2O4

    Science.gov (United States)

    Xu, Xiaoshan

    2010-03-01

    Iron-based multiferroics such as BiFeO3 and LuFe2O4 exhibit the highest magnetic and ferroelectric ordering temperatures among known multiferroics. LuFe2O4 is a frustrated system with several phase transitions that result in electronically driven multiferroicity. To understand how this peculiar multiferroic mechanism correlates with magnetism, we studied electronic excitations by optical spectroscopy and other complementary techniques. We show that the charge order, which determines the dielectric properties, is due to the ``order by fluctuation'' mechanism, evidenced by the onset of charge fluctuation well below the charge ordering transition. We also find a low temperature monoclinic distortion driven by both temperature and magnetic field, indicating strong coupling between structure, magnetism and charge order. BiFeO3 is the only known single phase multiferroics with room temperature magnetism and ferroelectricity. To investigate the spin-charge coupling, we measured the optical properties of BiFeO3. We find that the absorption onset occurs due to on-site Fe^3+ excitations at 1.41 and 1.90 eV. Temperature and magnetic-field-induced spectral changes reveal complex interactions between on-site crystal-field and magnetic excitations in the form of magnon sidebands. The sensitivity of the magnon sidebands allows us to map out the magnetic-field temperature phase diagram which demonstrates optical evidence for spin spiral quenching above 20 T and suggests a spin domain reorientation near 10 T. Work done in collaboration with T.V. Brinzari, R.C. Rai, M. Angst, R.P. Hermann, A.D. Christianson, J.-W. Kim, Z. Islam, B.C. Sales, D. Mandrus, S. Lee, Y.H. Chu, L. W. Martin, A. Kumar, R. Ramesh, S.W. Cheong, S. McGill, and J.L. Musfeldt.

  7. Validation and qualification of surface-applied fibre optic strain sensors using application-independent optical techniques

    International Nuclear Information System (INIS)

    Schukar, Vivien G; Kadoke, Daniel; Kusche, Nadine; Münzenberger, Sven; Gründer, Klaus-Peter; Habel, Wolfgang R

    2012-01-01

    Surface-applied fibre optic strain sensors were investigated using a unique validation facility equipped with application-independent optical reference systems. First, different adhesives for the sensor's application were analysed regarding their material properties. Measurements resulting from conventional measurement techniques, such as thermo-mechanical analysis and dynamic mechanical analysis, were compared with measurements resulting from digital image correlation, which has the advantage of being a non-contact technique. Second, fibre optic strain sensors were applied to test specimens with the selected adhesives. Their strain-transfer mechanism was analysed in comparison with conventional strain gauges. Relative movements between the applied sensor and the test specimen were visualized easily using optical reference methods, digital image correlation and electronic speckle pattern interferometry. Conventional strain gauges showed limited opportunities for an objective strain-transfer analysis because they are also affected by application conditions. (paper)

  8. Advanced materials and techniques for fiber-optic sensing

    International Nuclear Information System (INIS)

    Henderson, P. J.

    2013-01-01

    Fibre-optic monitoring systems came of age in about 1999 upon the emergence of the world's first significant commercialising company - a spin-out from the UK's collaborative MAST project. By using embedded fibre-optic technology, the MAST project successfully measured transient strain within high-performance composite yacht masts. Since then, applications have extended from smart composites into civil engineering, energy, military, aerospace, medicine and other sectors. Fibre-optic sensors come in various forms, and may be subject to embedment, retrofitting, and remote interrogation. The unique challenges presented by each implementation require careful scrutiny before widespread adoption can take place. Accordingly, various aspects of design and reliability are discussed spanning a range of representative technologies that include resonant microsilicon structures, MEMS, Bragg gratings, advanced forms of spectroscopy, and modern trends in nanotechnology. (author)

  9. A preferential coating technique for fabricating large, high quality optics

    International Nuclear Information System (INIS)

    Alcock, S.G.; Cockerton, S.

    2010-01-01

    A major challenge facing optic manufacturers is the fabrication of large mirrors (>1 m) with minimal residual slope errors (<0.5 μrad rms). We present a differential coating method with the potential to satisfy such exacting technical demands. Iterative cycles of measurement using the Diamond-NOM, followed by preferential deposition, were performed on a 1200 mm long, silicon mirror. The applied coatings were observed to reduce the optical slope and figure errors from 1.62 to 0.44 μrad rms, and from 208 to 13 nm rms, respectively. It is hoped that this research will lead to commercially available products, of direct benefit to the Synchrotron, Free Electron Laser, Astronomy, Space, and Laser communities, who all require state-of-the-art optics.

  10. Light scattering techniques for the characterization of optical components

    Science.gov (United States)

    Hauptvogel, M.; Schröder, S.; Herffurth, T.; Trost, M.; von Finck, A.; Duparré, A.; Weigel, T.

    2017-11-01

    The rapid developments in optical technologies generate increasingly higher and sometimes completely new demands on the quality of materials, surfaces, components, and systems. Examples for such driving applications are the steadily shrinking feature sizes in semiconductor lithography, nanostructured functional surfaces for consumer optics, and advanced optical systems for astronomy and space applications. The reduction of surface defects as well as the minimization of roughness and other scatter-relevant irregularities are essential factors in all these areas of application. Quality-monitoring for analysing and improving those properties must ensure that even minimal defects and roughness values can be detected reliably. Light scattering methods have a high potential for a non-contact, rapid, efficient, and sensitive determination of roughness, surface structures, and defects.

  11. Fiber break location technique utilizing stimulated Brillouin scattering effects in optical fiber

    International Nuclear Information System (INIS)

    Bakar, A A A; Al-Mansoori, M H; Mahdi, M A; Mohd Azau, M A; Zainal Abidin, M S

    2009-01-01

    A new technique of fiber break detection system in optical communication networks is proposed and experimentally demonstrated in this paper. This technique is based-on continuous wave light source rather than pulsed source that is commonly deployed in existing techniques. The nonlinear effect of stimulated Brillouin scattering is manipulated to locate the fiber-break position in optical communication networks. This technique enables the utilization of a less-sensitive photodetector to detect the Brillouin Stokes line since its intensity increases with the fiber length in the detectable region. The fiber break location can be determined with accuracy of more than 98% for fiber length less than 50 km using this technique

  12. Optical constants of CH3NH3PbBr3 perovskite thin films measured by spectroscopic ellipsometry

    KAUST Repository

    Alias, Mohd Sharizal; Dursun, Ibrahim; Saidaminov, Makhsud I.; Diallo, Elhadj Marwane; Mishra, Pawan; Ng, Tien Khee; Bakr, Osman; Ooi, Boon S.

    2016-01-01

    function) of CH3NH3PbBr3 perovskite thin films using spectroscopic ellipsometry. Due to the existence of voids, the refractive index of the thin films is around 8% less than the single crystals counterpart. The energy bandgap is around 2.309 eV as obtained

  13. Optical techniques for broadband in-building networks

    NARCIS (Netherlands)

    Yang, H.

    2011-01-01

    Optical fibres, which can easily handle any bandwidth demand, have been rolled out to more than 32 million consumer’s homes and professional buildings worldwide up to 2010. The basic technological and economical challenges of fibre-to-the-home (FTTH) has been solved. The current FTTH technology can

  14. Optical microphone with fiber Bragg grating and signal processing techniques

    Science.gov (United States)

    Tosi, Daniele; Olivero, Massimo; Perrone, Guido

    2008-06-01

    In this paper, we discuss the realization of an optical microphone array using fiber Bragg gratings as sensing elements. The wavelength shift induced by acoustic waves perturbing the sensing Bragg grating is transduced into an intensity modulation. The interrogation unit is based on a fixed-wavelength laser source and - as receiver - a photodetector with proper amplification; the system has been implemented using devices for standard optical communications, achieving a low-cost interrogator. One of the advantages of the proposed approach is that no voltage-to-strain calibration is required for tracking dynamic shifts. The optical sensor is complemented by signal processing tools, including a data-dependent frequency estimator and adaptive filters, in order to improve the frequency-domain analysis and mitigate the effects of disturbances. Feasibility and performances of the optical system have been tested measuring the output of a loudspeaker. With this configuration, the sensor is capable of correctly detecting sounds up to 3 kHz, with a frequency response that exhibits a top sensitivity within the range 200-500 Hz; single-frequency input sounds inducing an axial strain higher than ~10nɛ are correctly detected. The repeatability range is ~0.1%. The sensor has also been applied for the detection of pulsed stimuli generated from a metronome.

  15. Optical techniques for the study of living tissue

    NARCIS (Netherlands)

    Margallo Balbás, E.

    2010-01-01

    The potential of light in diagnosis and therapy has been long recognised. With the advent of scientific progress in our understanding of light propagation and interaction with tissue and parallel major technological advances in how optical energy can be generated, detected and processed, this

  16. Optical techniques for solid-state materials characterization

    CERN Document Server

    Prasankumar, Rohit P

    2016-01-01

    This book has comprehensively covered the essential optical approaches needed for solid-state materials characterization. Written by experts in the field, this will be a great reference for students, engineers, and scientists.-Professor Yoke Khin Yap, Michigan Technical University.

  17. A simple optical spectral calibration technique for pulsed THz sources

    NARCIS (Netherlands)

    Wijnen, F.J.P.; G. Berden,; Jongma, R.T.

    2010-01-01

    We have quantified the sensitivity of a simple method to measurethe frequency spectrum of pulsed terahertz (THz) radiation. The THzpulses are upconverted to the optical regime by sideband generation in a zinctelluride (ZnTe) crystal using a continuous wave (cw) narrow-bandwidthnear-infrared laser. A

  18. Using non-invasive molecular spectroscopic techniques to detect unique aspects of protein Amide functional groups and chemical properties of modeled forage from different sourced-origins.

    Science.gov (United States)

    Ji, Cuiying; Zhang, Xuewei; Yu, Peiqiang

    2016-03-05

    The non-invasive molecular spectroscopic technique-FT/IR is capable to detect the molecular structure spectral features that are associated with biological, nutritional and biodegradation functions. However, to date, few researches have been conducted to use these non-invasive molecular spectroscopic techniques to study forage internal protein structures associated with biodegradation and biological functions. The objectives of this study were to detect unique aspects and association of protein Amide functional groups in terms of protein Amide I and II spectral profiles and chemical properties in the alfalfa forage (Medicago sativa L.) from different sourced-origins. In this study, alfalfa hay with two different origins was used as modeled forage for molecular structure and chemical property study. In each forage origin, five to seven sources were analyzed. The molecular spectral profiles were determined using FT/IR non-invasive molecular spectroscopy. The parameters of protein spectral profiles included functional groups of Amide I, Amide II and Amide I to II ratio. The results show that the modeled forage Amide I and Amide II were centered at 1653 cm(-1) and 1545 cm(-1), respectively. The Amide I spectral height and area intensities were from 0.02 to 0.03 and 2.67 to 3.36 AI, respectively. The Amide II spectral height and area intensities were from 0.01 to 0.02 and 0.71 to 0.93 AI, respectively. The Amide I to II spectral peak height and area ratios were from 1.86 to 1.88 and 3.68 to 3.79, respectively. Our results show that the non-invasive molecular spectroscopic techniques are capable to detect forage internal protein structure features which are associated with forage chemical properties. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Spectroscopic techniques (Mössbauer spectrometry, NMR, ESR,…) as tools to resolve doubtful NMR images: Study of the craniopharyngioma tumor

    Science.gov (United States)

    Rimbert, J. N.; Dumas, F.; Lafargue, C.; Kellershohn, C.; Brunelle, F.; Lallemand, D.

    1990-07-01

    Craniopharyngioma, an intracranial tumor, exhibits hyperintensity in the Spin-Echo-T2-NMR image and a hyposignal in the SE-T1-image. However, in some cases (15-20% cases), hypersignals are seen in both SE-T1 and T2-MRI. Using spectroscopic techniques, Mössbauer spectrometry in particular, we have demonstrated that the T1 hypersignal is due to ferritin, dissolved in the cystic liquid, after tumor cell lysis, in the course of time. Other possible reasons inducing a shortening of the T1 relaxation time (presence of lipids, intratumoral hemorrhage) have been rejected.

  20. A technique for aligning sextupole systems using beam optics

    International Nuclear Information System (INIS)

    Chao, Yu-Chiu.

    1992-03-01

    A technique for beam based alignment of sextupole system is developed exploiting the enhancement effect of orbit differences by the sextupoles. This technique can in principle be applied to sextupole or sextupole strings with controlled orbit pattern and BPM configurations. This paper will discuss the theoretical basis, special optimization considerations and expected accuracy. Application to the SLC final focus is also discussed

  1. Gold and silver thin film analysis by optical and neutron activation techniques

    International Nuclear Information System (INIS)

    Moharram, B.M.; El-Khatib, A.M.; Ammar, E.A.

    1989-01-01

    Thicknesses of gold and silver thin films have been determined by NAA technique. Reasonable agreement with conventional optical methods has been obtained, but the lower detection limit in the case of NAA is far better than in the optical method. (author)

  2. Optically stimulated luminescence from quartz measured using the linear modulation technique

    DEFF Research Database (Denmark)

    Bulur, E.; Bøtter-Jensen, L.; Murray, A.S.

    2000-01-01

    The optically stimulated luminescence (OSL) from heated natural quartz has been investigated using the linear modulation technique (LMT), in which the excitation light intensity is increased linearly during stimulation. In contrast to conventional stimulation, which usually produces a monotonical...

  3. The Development of a Differential Deposition Technique for Figure Correction in Grazing Incidence Optics

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the development of a physical-vapor-deposition coating technique to correct residual figure errors in grazing-incidence optics. The process involves...

  4. Principles of optical fibre communication techniques: Noncoherent and coherent

    International Nuclear Information System (INIS)

    Jain, V.K.

    1990-01-01

    In this paper a brief historical description of optical fibre communication system (OFCS) has been presented and the main characteristics of the basic components used in it are summarized. Introduction of noncoherent and coherent (homodyne and heterodyne) system is given. In coherent OFCS, source linewidth requirement, phase and polarization - diversity and combined phase and polarization - diversity receivers are described. (author). 16 refs, 8 figs, 1 tab

  5. Development of in-core measuring method using optical techniques

    International Nuclear Information System (INIS)

    Kakuta, Tsunemi; Shikama, Tatsuo; Narui, Minoru; Sagawa, Tsutomu.

    1994-01-01

    Since applying to more severe radiation environments in nuclear plants, e.g., in-core measuring systems, diagnostics for fusion reactors, radiation related subjects should be considered by more severe radiation and environmental conditions. Owing to this, preliminary studies of heavy neutron irradiation effects on optical fibers are conducted in the core region of fission reactor. Two kinds of SiO 2 core optical fibers, highly pure SiO 2 with OH content core and SiO 2 with fluorine doped core, were irradiated in the core region of Japan Material Testing Reactor (JMTR). Both fibers were irradiated with fast neutron (E>1.0 MeV) fluence of about 1.6x10 19 n/cm 2 and gamma-ray doses of 3.3x10 9 Gy. The optical absorption and the light-emission spectrum were measured in-situ along the irradiation. This paper mainly outlines the fundamental effects of neutron irradiation and discuss the possibility of neutron detection in the core region of reactor. (J.P.N.)

  6. [The Autocad system for planimetric study of the optic disc in glaucoma: technique and reproducibility study].

    Science.gov (United States)

    Sánchez Pérez, A; Honrubia López, F M; Larrosa Poves, J M; Polo Llorens, V; Melcon Sánchez-Frieras, B

    2001-09-01

    To develop a lens planimetry technique for the optic disc using AutoCAD. To determine variability magnitude of the optic disc morphological measurements. We employed AutoCAD R.14.0 Autodesk: image acquisition, contour delimitation by multiple lines fitting or ellipse adjustment, image sectorialization and measurements quantification (optic disc and excavation, vertical diameters, optic disc area, excavation area, neuroretinal sector area and Beta atrophy area). Intraimage or operator and interimage o total reproducibility was studied by coefficient of variability (CV) (n=10) in normal and myopic optic discs. This technique allows to obtain optic disc measurement in 5 to 10 minutes time. Total or interimage variability of measurements introduced by one observer presents CV range from 1.18-4.42. Operator or intraimage measurement presents CV range from 0.30-4.21. Optic disc contour delimitation by ellipse adjustment achieved better reproducibility results than multiple lines adjustment in all measurements. Computer assisted AutoCAD planimetry is an interactive method to analyse the optic disc, feasible to incorporate to clinical practice. Reproducibility results are comparable to other analyzers in quantification optic disc morphology. Ellipse adjustment improves results in optic disc contours delimitation.

  7. Pulse shaping using the optical Fourier transform technique - for ultra-high-speed signal processing

    DEFF Research Database (Denmark)

    Palushani, Evarist; Oxenløwe, Leif Katsuo; Galili, Michael

    2009-01-01

    This paper reports on the generation of a 1.6 ps FWHM flat-top pulse using the optical Fourier transform technique. The pulse is validated in a 320 Gbit/s demultiplexing experiment.......This paper reports on the generation of a 1.6 ps FWHM flat-top pulse using the optical Fourier transform technique. The pulse is validated in a 320 Gbit/s demultiplexing experiment....

  8. Refractive index sensor based on optical fiber end face using pulse reference-based compensation technique

    Science.gov (United States)

    Bian, Qiang; Song, Zhangqi; Zhang, Xueliang; Yu, Yang; Chen, Yuzhong

    2018-03-01

    We proposed a refractive index sensor based on optical fiber end face using pulse reference-based compensation technique. With good compensation effect of this compensation technique, the power fluctuation of light source, the change of optic components transmission loss and coupler splitting ratio can be compensated, which largely reduces the background noise. The refractive index resolutions can achieve 3.8 × 10-6 RIU and1.6 × 10-6 RIU in different refractive index regions.

  9. Heterodyne technique for measuring the amplitude and phase transfer functions of an optical modulator

    DEFF Research Database (Denmark)

    Romstad, Francis Pascal; Birkedal, Dan; Mørk, Jesper

    2002-01-01

    In this letter, we propose a technique based on heterodyne detection for accurately and simultaneously measuring the amplitude and phase transfer functions of an optical modulator. The technique is used to characterize an InGaAsp multiple quantum-well electroabsorption modulator. From the measure...... the measurements we derive the small-signal alpha-parameter and the time-dependent chirp for different operation conditions.......In this letter, we propose a technique based on heterodyne detection for accurately and simultaneously measuring the amplitude and phase transfer functions of an optical modulator. The technique is used to characterize an InGaAsp multiple quantum-well electroabsorption modulator. From...

  10. Ion beam induced defects in solids studied by optical techniques

    International Nuclear Information System (INIS)

    Comins, J.D.; Amolo, G.O.; Derry, T.E.; Connell, S.H.; Erasmus, R.M.; Witcomb, M.J.

    2009-01-01

    Optical methods can provide important insights into the mechanisms and consequences of ion beam interactions with solids. This is illustrated by four distinctly different systems. X- and Y-cut LiNbO 3 crystals implanted with 8 MeV Au 3+ ions with a fluence of 1 x 10 17 ions/cm 2 result in gold nanoparticle formation during high temperature annealing. Optical extinction curves simulated by the Mie theory provide the average nanoparticle sizes. TEM studies are in reasonable agreement and confirm a near-spherical nanoparticle shape but with surface facets. Large temperature differences in the nanoparticle creation in the X- and Y-cut crystals are explained by recrystallisation of the initially amorphised regions so as to recreate the prior crystal structure and to result in anisotropic diffusion of the implanted gold. Defect formation in alkali halides using ion beam irradiation has provided new information. Radiation-hard CsI crystals bombarded with 1 MeV protons at 300 K successfully produce F-type centres and V-centres having the I 3 - structure as identified by optical absorption and Raman studies. The results are discussed in relation to the formation of interstitial iodine aggregates of various types in alkali iodides. Depth profiling of I 3 - and I 5 - aggregates created in RbI bombarded with 13.6 MeV/A argon ions at 300 K is discussed. The recrystallisation of an amorphous silicon layer created in crystalline silicon bombarded with 100 keV carbon ions with a fluence of 5 x 10 17 ions/cm 2 during subsequent high temperature annealing is studied by Raman and Brillouin light scattering. Irradiation of tin-doped indium oxide (ITO) films with 1 MeV protons with fluences from 1 x 10 15 to 250 x 10 15 ions/cm -2 induces visible darkening over a broad spectral region that shows three stages of development. This is attributed to the formation of defect clusters by a model of defect growth and also high fluence optical absorption studies. X-ray diffraction studies show

  11. Ion beam induced defects in solids studied by optical techniques

    Science.gov (United States)

    Comins, J. D.; Amolo, G. O.; Derry, T. E.; Connell, S. H.; Erasmus, R. M.; Witcomb, M. J.

    2009-08-01

    Optical methods can provide important insights into the mechanisms and consequences of ion beam interactions with solids. This is illustrated by four distinctly different systems. X- and Y-cut LiNbO 3 crystals implanted with 8 MeV Au 3+ ions with a fluence of 1 × 10 17 ions/cm 2 result in gold nanoparticle formation during high temperature annealing. Optical extinction curves simulated by the Mie theory provide the average nanoparticle sizes. TEM studies are in reasonable agreement and confirm a near-spherical nanoparticle shape but with surface facets. Large temperature differences in the nanoparticle creation in the X- and Y-cut crystals are explained by recrystallisation of the initially amorphised regions so as to recreate the prior crystal structure and to result in anisotropic diffusion of the implanted gold. Defect formation in alkali halides using ion beam irradiation has provided new information. Radiation-hard CsI crystals bombarded with 1 MeV protons at 300 K successfully produce F-type centres and V-centres having the I3- structure as identified by optical absorption and Raman studies. The results are discussed in relation to the formation of interstitial iodine aggregates of various types in alkali iodides. Depth profiling of I3- and I5- aggregates created in RbI bombarded with 13.6 MeV/A argon ions at 300 K is discussed. The recrystallisation of an amorphous silicon layer created in crystalline silicon bombarded with 100 keV carbon ions with a fluence of 5 × 10 17 ions/cm 2 during subsequent high temperature annealing is studied by Raman and Brillouin light scattering. Irradiation of tin-doped indium oxide (ITO) films with 1 MeV protons with fluences from 1 × 10 15 to 250 × 10 15 ions/cm -2 induces visible darkening over a broad spectral region that shows three stages of development. This is attributed to the formation of defect clusters by a model of defect growth and also high fluence optical absorption studies. X-ray diffraction studies show

  12. Spectroscopic ellipsometric modeling of a Bi–Te–Se write layer of an optical data storage device as guided by atomic force microscopy, scanning electron microscopy, and X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hao; Madaan, Nitesh; Bagley, Jacob; Diwan, Anubhav [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States); Liu, Yiqun [Department of Chemistry, Lehigh University, Bethlehem, PA 18015 (United States); Davis, Robert C. [Department of Physics and Astronomy, Brigham Young University, Provo, UT 84602 (United States); Lunt, Barry M. [Department of Information Technology, Brigham Young University, Provo, UT 84602 (United States); Smith, Stacey J., E-mail: ssmith@chem.byu.edu [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States); Linford, Matthew R., E-mail: mrlinford@chem.byu.edu [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States)

    2014-10-31

    Conventional magnetic tape is the most widely used medium for archival data storage. However, data stored on it need to be migrated every ca. 5 years. Recently, optical discs that store information for hundreds, or even more than 1000 years, have been introduced to the market. We recently proposed that technology in these optical discs be used to make an optical tape that would show greater permanence than its magnetic counterpart. Here we provide a detailed optical characterization of a sputtered thin film of bismuth, tellurium, and selenium (BTS) that is a proposed data storage layer for these devices. The methodology described herein should be useful in the future development of related materials. Spectroscopic ellipsometry (SE) data are obtained using interference enhancement, and the modeling of this data is guided by results from atomic force microscopy (AFM), scanning electron microscopy (SEM), X-ray diffraction (XRD), and X-ray reflectivity (XRR). By AFM, ca. 40 nm BTS films show ca. 10 nm roughness. SEM images also suggest considerable roughness in the films and indicate that they are composed of 13.1 ± 5.9 nm grains. XRD confirms that the films are crystalline and predicts a grain size of 17 ± 2 nm. XRD results are consistent with the composition of the films — a mildly oxidized BTS material. Three models of increasing complexity are investigated to explain the SE data. The first model consists of a smooth, homogeneous BTS film. The second model adds a roughness layer to the previous model. The third model also has two layers. The bottom layer is modeled as a mixture of BTS and void using a Bruggeman effective medium approximation. The upper layer is similarly modeled, but with a gradient. The first model was unable to adequately model the SE data. The second model was an improvement — lower MSE (4.4) and good agreement with step height measurements. The third model was even better — very low MSE (2.6) and good agreement with AFM results. The

  13. Frequency-Shifted Interferometry — A Versatile Fiber-Optic Sensing Technique

    Directory of Open Access Journals (Sweden)

    Fei Ye

    2014-06-01

    Full Text Available Fiber-optic sensing is a field that is developing at a fast pace. Novel fiber-optic sensor designs and sensing principles constantly open doors for new opportunities. In this paper, we review a fiber-optic sensing technique developed in our research group called frequency-shifted interferometry (FSI. This technique uses a continuous-wave light source, an optical frequency shifter, and a slow detector. We discuss the operation principles of several FSI implementations and show their applications in fiber length and dispersion measurement, locating weak reflections along a fiber link, fiber-optic sensor multiplexing, and high-sensitivity cavity ring-down measurement. Detailed analysis of FSI system parameters is also presented.

  14. Actively stabilized optical fiber interferometry technique for online/in-process surface measurement

    International Nuclear Information System (INIS)

    Wang Kaiwei; Martin, Haydn; Jiang Xiangqian

    2008-01-01

    In this paper, we report the recent progress in optical-beam scanning fiber interferometry for potential online nanoscale surface measurement based on the previous research. It attempts to generate a robust and miniature measurement device for future development into a multiprobe array measurement system. In this research, both fiber-optic-interferometry and the wavelength-division-multiplexing techniques have been used, so that the optical probe and the optical interferometer are well spaced and fast surface scanning can be carried out, allowing flexibility for online measurement. In addition, this system provides a self-reference signal to stabilize the optical detection with high common-mode noise suppression by adopting an active phase tracking and stabilization technique. Low-frequency noise was significantly reduced compared with unstabilized result. The measurement of a sample surface shows an attained repeatability of 3.3 nm

  15. Interaction of Flavonoids from Woodwardia unigemmata with Bovine Serum Albumin (BSA): Application of Spectroscopic Techniques and Molecular Modeling Methods.

    Science.gov (United States)

    Ma, Rui; Pan, Hong; Shen, Tao; Li, Peng; Chen, Yanan; Li, Zhenyu; Di, Xiaxia; Wang, Shuqi

    2017-08-09

    Phytochemical investigation on the methanol extract of Woodwardia unigemmata resulted in the isolation of seven flavonoids, including one new flavonol acylglycoside ( 1 ). The structures of these compounds were elucidated on the basis of extensive spectroscopic analysis and comparison of literature data. The multidrug resistance (MDR) reversing activity was evaluated for the isolated compounds using doxorubicin-resistant K562/A02 cells model. Compound 6 showed comparable MDR reversing effect to verapamil. Furthermore, the interaction between compounds and bovine serum albumin (BSA) was investigated by spectroscopic methods, including steady-state fluorescence, synchronous fluorescence, circular dichroism (CD) spectroscopies, and molecular docking approach. The experimental results indicated that the seven flavonoids bind to BSA by static quenching mechanisms. The negative ΔH and ΔS values indicated that van der Waals interactions and hydrogen bonds contributed in the binding of compounds 2 - 6 to BSA. In the case of compounds 1 and 7 systems, the hydrophobic interactions play a major role. The binding of compounds to BSA causes slight changes in the secondary structure of BSA. There are two binding sites of compound 6 on BSA and site I is the main site according to the molecular docking studies and the site marker competitive binding assay.

  16. Z-scan: A simple technique for determination of third-order optical nonlinearity

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Vijender, E-mail: chahal-gju@rediffmail.com [Department of Applied Science, N.C. College of Engineering, Israna, Panipat-132107, Haryana (India); Aghamkar, Praveen, E-mail: p-aghamkar@yahoo.co.in [Department of Physics, Chaudhary Devi Lal University, Sirsa-125055, Haryana (India)

    2015-08-28

    Z-scan is a simple experimental technique to measure intensity dependent nonlinear susceptibilities of third-order nonlinear optical materials. This technique is used to measure the sign and magnitude of both real and imaginary part of the third order nonlinear susceptibility (χ{sup (3)}) of nonlinear optical materials. In this paper, we investigate third-order nonlinear optical properties of Ag-polymer composite film by using single beam z-scan technique with Q-switched, frequency doubled Nd: YAG laser (λ=532 nm) at 5 ns pulse. The values of nonlinear absorption coefficient (β), nonlinear refractive index (n{sub 2}) and third-order nonlinear optical susceptibility (χ{sup (3)}) of permethylazine were found to be 9.64 × 10{sup −7} cm/W, 8.55 × 10{sup −12} cm{sup 2}/W and 5.48 × 10{sup −10} esu, respectively.

  17. Data transmission techniques for short-range optical fiber and wireless communication links

    DEFF Research Database (Denmark)

    Pham, Tien Thang

    The research work described in this thesis is devoted to experimental investigation of techniques for cost-effective high-speed optical communications supporting both wired and wireless services. The main contributions of this thesis have expanded the state-of-the-art in two main areas: high......-speed optical/wireless integration and advanced modulation formats for intensity modulation with direct detection (IM/DD) optical systems. Regarding optical/wireless integration, this thesis focuses on integration of broadband ultra-wide band (UWB) and 60-GHz band wireless systems into optical fiber access...... networks to distribute wireless services in personal area networks (PANs). Photonic technologies to generate and distribute gigabit UWB and 60-GHz-band signals are proposed and demonstrated. Two novel methods are proposed and demonstrated to optically generate Federal Communications Commission (FCC...

  18. Code division multiple-access techniques in optical fiber networks. II - Systems performance analysis

    Science.gov (United States)

    Salehi, Jawad A.; Brackett, Charles A.

    1989-08-01

    A technique based on optical orthogonal codes was presented by Salehi (1989) to establish a fiber-optic code-division multiple-access (FO-CDMA) communications system. The results are used to derive the bit error rate of the proposed FO-CDMA system as a function of data rate, code length, code weight, number of users, and receiver threshold. The performance characteristics for a variety of system parameters are discussed. A means of reducing the effective multiple-access interference signal by placing an optical hard-limiter at the front end of the desired optical correlator is presented. Performance calculations are shown for the FO-CDMA with an ideal optical hard-limiter, and it is shown that using a optical hard-limiter would, in general, improve system performance.

  19. Micro reflectance difference techniques: Optical probes for surface exploration

    Energy Technology Data Exchange (ETDEWEB)

    Lastras-Martinez, L.F.; Del Pozo-Zamudio, O.; Herrera-Jasso, R.; Ulloa-Castillo, N.A.; Balderas-Navarro, R.E.; Ortega-Gallegos, J.; Lastras-Martinez, A. [Instituto de Investigacion en Comunicacion Optica, Universidad Autonoma de San Luis Potosi, Alvaro Obregon 64, 78000 San Luis Potosi, S.L.P. (Mexico)

    2012-06-15

    Micro reflectance difference spectroscopy ({mu}-RDS) is a promising tool for the in-situ and ex-situ characterization of semiconductors surfaces and interfaces. We discuss and compare two different approaches used to measure {mu}-RD spectra. One is based on a charge-coupled device (CCD) camera, while the other uses a laser and a XY translation stage. To show the performance of these systems, we have measured surface optical anisotropies of GaSb(001) sample on which anisotropic strains have been generated by preferential mechanical polishing along [110] and [1 anti 10] directions. The spectrometers are complementary and the selection of one of them depends on the sample to be investigated and on experimental conditions. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Fundamentals and techniques of nonimaging optics for solar energy concentration

    Science.gov (United States)

    Winston, R.; Ogallaher, J. J.

    1980-09-01

    Recent progress in basic research into the theoretical understanding of nonimaging optical systems and their application to the design of practical solar concentration was reviewed. Work was done to extend the previously developed geometrical vector flux formalism with the goal of applying it to the analysis of nonideal concentrators. Both phase space and vector flux representation for traditional concentrators were generated. Understanding of the thermodynamically derived relationship between concentration and cavity effects led to the design of new lossless and low loss concentrators for absorbers with gaps. Quantitative measurements of the response of real collector systems and the distribution of diffuse insolation shows that in most cases performance exceeds predictions in solar applications. These developments led to improved nonimaging solar concentrator designs and applications.

  1. Advanced Equalization Techniques for Digital Coherent Optical Receivers

    DEFF Research Database (Denmark)

    Arlunno, Valeria

    approach based on joint encoding and equalization technique, known as Turbo Equalization (TE). This scheme is demonstrated to be powerful in transmission impairments mitigation for high order modulations formats, such as 16 Quadrature Amplitude Modulation (QAM), considered a key technology for high speed...... a lower complexity convolutional code compared to state of the art reports. Furthermore, in order to fulfill the strict constrains of spectral efficiency, this thesis shows the application of digital adaptive equalizer for reconfigurable and Ultra Dense Wavelength Division Multiplexing (U......-over-Fiber (RoF) transmission system for a stand alone case and mixed modulation mixed bit rates transmission scheme. In conclusion, this PhD thesis demonstrates the flexibility, upgrade-ability and robustness offered by rising advanced digital signal processing techniques, for future high-speed, high...

  2. Ultrabroadband Phased-Array Receivers Based on Optical Techniques

    Science.gov (United States)

    2016-02-26

    bandwidths, and with it receiver noise floors , are unavoidable. Figure 1. SNR of a thermally limited receiver based on Friis equation showing the...techniques for RF and photonic integration based on liquid crystal polymer substrates were pursued that would aid in the realization of potential imaging...These models assumed that sufficient LNA gain was used on the antenna to set the noise floor of the imaging receiver, which necessitated physical

  3. Applications Of Measurement Techniques To Develop Small-Diameter, Undersea Fiber Optic Cables

    Science.gov (United States)

    Kamikawa, Neil T.; Nakagawa, Arthur T.

    1984-12-01

    Attenuation, strain, and optical time domain reflectometer (OTDR) measurement techniques were applied successfully in the development of a minimum-diameter, electro-optic sea floor cable. Temperature and pressure models for excess attenuation in polymer coated, graded-index fibers were investigated analytically and experimentally using these techniques in the laboratory. The results were used to select a suitable fiber for the cable. Measurements also were performed on these cables during predeployment and sea-trial testing to verify laboratory results. Application of the measurement techniques and results are summarized in this paper.

  4. Tunable optical properties of plasmonic Au/Al2O3 nanocomposite thin films analyzed by spectroscopic ellipsometry accounting surface characteristics.

    Science.gov (United States)

    Jaiswal, Jyoti; Mourya, Satyendra; Malik, Gaurav; Chandra, Ramesh

    2018-05-01

    In the present work, we have fabricated plasmonic gold/alumina nanocomposite (Au/Al 2 O 3 NC) thin films on a glass substrate at room temperature by RF magnetron co-sputtering. The influence of the film thickness (∼10-40  nm) on the optical and other physical properties of the samples was investigated and correlated with the structural and compositional properties. The X-ray diffractometer measurement revealed the formation of Au nanoparticles with average crystallite size (5-9.2 nm) embedded in an amorphous Al 2 O 3 matrix. The energy-dispersive X ray and X-ray photoelectron spectroscopy results confirmed the formation of Au/Al 2 O 3 NC quantitatively and qualitatively and it was observed that atomic% of Au increased by increasing thickness. The optical constants of the plasmonic Au/Al 2 O 3 NC thin films were examined by variable angle spectroscopic ellipsometry in the wide spectral range of 246-1688 nm, accounting the surface characteristics in the optical stack model, and the obtained results are expected to be unique. Additionally, a thickness-dependent blueshift (631-590 nm) of surface plasmon resonance peak was observed in the absorption spectra. These findings of the plasmonic Au/Al 2 O 3 NC films may allow the design and fabrication of small, compact, and efficient devices for optoelectronic and photonic applications.

  5. Development of optical techniques for chemical engineering applications

    Energy Technology Data Exchange (ETDEWEB)

    Lamadie, F.; Charton, S.; Langlard, M. de; Ouattara, M.; Sentis, M. [CEA, Centre de Marcoule, DEN,DTEC,SGCS, F-30207 Marcoule (France)

    2016-07-01

    The design of separation processes for nuclear spend fuel treatment, dedicated to either research studies or industrial applications, is currently based on a phenomenological approach, relying on Computational Fluid Dynamics, and complemented by validation tests performed at small-scale. Indeed, most of the steps of the Purex process involve multiphasic flows (dissolution, leaching, liquid-liquid extraction, precipitation, filtration, etc.). Therefore an accurate knowledge of the dispersed phase properties is required in order to assess their coupling with the flow features, to predict the process performance and efficiency and to achieve size reduction or extrapolation. Hence, the measurements of particulate flows properties, and especially the particles (or drops or bubbles) size distribution, concentration (i.e. hold-up) and velocity has become a growing issue. Relevant techniques for measuring these flow properties are multiple, from the high-speed video acquisition coupled to image processing to the laser-induced fluorescence, including the particle imaging velocimetry or interferometric techniques (digital in-line holography, rainbow refractometry, etc.). In this communication, different techniques developed at CEA Marcoule for the characterization of multiphase flows, will be introduced. The strong interaction with computational fluid dynamics, in the scope of a multi-scale approach, will be discussed through typical results of gas-liquid, liquid-liquid and solid-liquid flows possibly encountered in nuclear fuel reprocessing process. (authors)

  6. Spectroscopic and non-linear optical studies of two novel optical limiters from dichloroaniline family crystals: 3,4-Dichloroaniline and 3,5-dichloroaniline

    Science.gov (United States)

    Sasikala, V.; Sajan, D.; Joseph, Lynnette; Narayana, Badiadka; Sarojini, Balladka K.

    2017-11-01

    Two organic crystals of the isomeric forms of dichloroanilines such as 3, 4-dichloroaniline (3,4-DCA) and 3, 5-dichloroaniline (3,5-DCA) were grown by slow evaporation method and characterized by various analytical techniques. The vibrational normal modes of the samples were theoretically predicted using the scaled quantum mechanical force field procedures with the DFT level calculation and the potential energy distributions of the individual modes were estimated using the normal coordinate analysis. Fermi doublets and Evans holes were identified in the vibrational spectra of samples. The nuclear relaxation contribution to the vibrational polarizabilities and hyperpolarizabilities for the normal modes of the molecules were quantitatively estimated using the DFT method. The results of the calculated NLO responses showed that the vibrational mean contributions to the static polarizabilities and hyperpolarizabilities were smaller than the corresponding electronic contributions for the molecules. The Kurtz and Perry powder SHG efficiencies were measured and both samples have generated the second-harmonics of the fundamentals. The open-aperture Z-scan study results proposed the superior optical limiting property of 3,5-DCA with respect to 3,4-DCA.

  7. Identification of vegetable oil botanical speciation in refined vegetable oil blends using an innovative combination of chromatographic and spectroscopic techniques.

    Science.gov (United States)

    Osorio, Maria Teresa; Haughey, Simon A; Elliott, Christopher T; Koidis, Anastasios

    2015-12-15

    European Regulation 1169/2011 requires producers of foods that contain refined vegetable oils to label the oil types. A novel rapid and staged methodology has been developed for the first time to identify common oil species in oil blends. The qualitative method consists of a combination of a Fourier Transform Infrared (FTIR) spectroscopy to profile the oils and fatty acid chromatographic analysis to confirm the composition of the oils when required. Calibration models and specific classification criteria were developed and all data were fused into a simple decision-making system. The single lab validation of the method demonstrated the very good performance (96% correct classification, 100% specificity, 4% false positive rate). Only a small fraction of the samples needed to be confirmed with the majority of oils identified rapidly using only the spectroscopic procedure. The results demonstrate the huge potential of the methodology for a wide range of oil authenticity work. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Probing the interaction of flower-like CdSe nanostructure particles targeted to bovine serum albumin using spectroscopic techniques

    International Nuclear Information System (INIS)

    Ju Peng; Fan Hai; Liu Tao; Cui Lin; Ai Shiyun

    2011-01-01

    The interaction between flower-like CdSe nanostructure particles (CdSe NP) and bovine serum albumin (BSA) was investigated from a spectroscopic angle under simulative physiological conditions. Under pH 7.4, CdSe NP could effectively quench the intrinsic fluorescence of BSA via static quenching. The binding constant (K A ) was 6.38, 3.27, and 1.90x10 4 M -1 at 298, 304, and 310 K, respectively and the number of binding sites was 1.20. According to the Van't Hoff equation, the thermodynamic parameters (ΔH o =-77.48 kJ mol -1 , ΔS o =-168.17 J mol -1 K -1 ) indicated that hydrogen bonds and van der Waals forces played a major role in stabilizing the BSA-CdSe complex. Besides, UV-vis and circular dichroism (CD) results showed that the addition of CdSe NP changed the secondary structure of BSA and led to a decrease in α-helix. These results suggested that BSA underwent substantial conformational changes induced by flower-like CdSe nanostructure particles. - Highlights: → Estimate the binding of flower-like CdSe NP to BSA by spectroscopic methods. → Hydrogen bonds and van der Waals forces were the major forces. →Addition of CdSe changed the micro-environmentl of BSA. → Decrease in α-helix of BSA secondary structure induced by CdSe.

  9. Interferometric and nonlinear-optical spectral-imaging techniques for outer space and live cells

    Science.gov (United States)

    Itoh, Kazuyoshi

    2015-12-01

    Multidimensional signals such as the spectral images allow us to have deeper insights into the natures of objects. In this paper the spectral imaging techniques that are based on optical interferometry and nonlinear optics are presented. The interferometric imaging technique is based on the unified theory of Van Cittert-Zernike and Wiener-Khintchine theorems and allows us to retrieve a spectral image of an object in the far zone from the 3D spatial coherence function. The retrieval principle is explained using a very simple object. The promising applications to space interferometers for astronomy that are currently in progress will also be briefly touched on. An interesting extension of interferometric spectral imaging is a 3D and spectral imaging technique that records 4D information of objects where the 3D and spectral information is retrieved from the cross-spectral density function of optical field. The 3D imaging is realized via the numerical inverse propagation of the cross-spectral density. A few techniques suggested recently are introduced. The nonlinear optical technique that utilizes stimulated Raman scattering (SRS) for spectral imaging of biomedical targets is presented lastly. The strong signals of SRS permit us to get vibrational information of molecules in the live cell or tissue in real time. The vibrational information of unstained or unlabeled molecules is crucial especially for medical applications. The 3D information due to the optical nonlinearity is also the attractive feature of SRS spectral microscopy.

  10. New techniques for optical absorption measurement of implanted nanoparticles in float glass

    International Nuclear Information System (INIS)

    Okur, I.; Townsend, P.D.; Chandler, P.J.

    1999-01-01

    New techniques are reported for optical absorption and waveguide loss measurement of copper, gold and silver implanted float glass. Implantations were carried out on the tin face of the float glass since this face is an optical waveguide. Specially made triangle shape masks were used during implantation to study the optical loss-implant length relation. Absorption coefficients were extracted as 2.4 and 1 cm -1 for the gold and silver implants at 633 nm, respectively. These values were found to be implant condition dependent. To analyse the shape of nanoparticles a sandwiched structure was used in an optical absorption measurement set-up in which two guiding faces were put in contact. The sandwiched structure places the colloids at the centre of the optical field distribution rather than on the boundary zone. These experiments have revealed that the copper and the gold particles may have non-spherical shapes, whereas for silver, the formation of spherical nanoparticles is more likely

  11. OPTICAL SPECTROSCOPIC OBSERVATIONS OF GAMMA-RAY BLAZAR CANDIDATES. V. TNG, KPNO, AND OAN OBSERVATIONS OF BLAZAR CANDIDATES OF UNCERTAIN TYPE IN THE NORTHERN HEMISPHERE

    Energy Technology Data Exchange (ETDEWEB)

    Álvarez Crespo, N.; Massaro, F. [Dipartimento di Fisica, Università degli Studi di Torino, via Pietro Giuria 1, I-10125 Torino (Italy); Masetti, N. [INAF—Istituto di Astrofisica Spaziale e Fisica Cosmica di Bologna, via Gobetti 101, I-40129, Bologna (Italy); Ricci, F.; La Franca, F. [Dipartimento di Matematica e Fisica, Università Roma Tre, via della Vasca Navale 84, I-00146, Roma (Italy); Landoni, M. [INAF-Osservatorio Astronomico di Brera, Via Emilio Bianchi 46, I-23807 Merate (Italy); Patiño-Álvarez, V.; Chavushyan, V.; Torrealba, J. [Instituto Nacional de Astrofisica, Óptica y Electrónica, Apartado Postal 51-216, 72000 Puebla, México (Mexico); D’Abrusco, R.; Paggi, A.; Smith, Howard A. [Harvard—Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, MA 02138 (United States); Jiménez-Bailón, E. [Instituto de Astronomía, Universidad Nacional Autónoma de México, Apdo. Postal 877, Ensenada, 22800 Baja California, México (Mexico); Latronico, L. [Istituto Nazionale di Fisica Nucleare, Sezione di Torino, I-10125 Torino (Italy); Tosti, G. [Dipartimento di Fisica, Università degli Studi di Perugia, I-06123 Perugia (Italy)

    2016-02-15

    The extragalactic γ-ray sky is dominated by emission from blazars, a peculiar class of active galactic nuclei. Many of the γ-ray sources included in the Fermi-Large Area Telescope Third Source catalog (3FGL) are classified as blazar candidates of uncertain type (BCUs) because there are no optical spectra available in the literature to confirm their nature. In 2013, we started a spectroscopic campaign to look for the optical counterparts of the BCUs and of the unidentified γ-ray sources to confirm their blazar nature. Whenever possible we also determine their redshifts. Here, we present the results of the observations carried out in the northern hemisphere in 2013 and 2014 at the Telescopio Nazionale Galileo, Kitt Peak National Observatory, and Observatorio Astronómico Nacional in San Pedro Mártir. In this paper, we describe the optical spectra of 25 sources. We confirmed that all of the 15 BCUs observed in our campaign and included in our sample are blazars and we estimated the redshifts for three of them. In addition, we present the spectra for three sources classified as BL Lacs in the literature but with no optical spectra available to date. We found that one of them is a quasar (QSO) at a redshift of z = 0.208 and the other two are BL Lacs. Moreover, we also present seven new spectra for known blazars listed in the Roma-BZCAT that have an uncertain redshift or are classified as BL Lac candidates. We found that one of them, 5BZB J0724+2621, is a “changing look” blazar. According to the spectrum available in the literature, it was classified as a BL Lac, but in our observation we clearly detected a broad emission line that led us to classify this source as a QSO at z = 1.17.

  12. Construction and use of an optical semi-automatic titrator employing the technique of reflectance photometry

    International Nuclear Information System (INIS)

    Hwang, Hoon

    2001-01-01

    An optical semi-automatic titrator was constructed employing the technique of the reflectance spectrometry and was tested for the determination of the end points of the acid-base, precipitation, and EDTA titrations. And since the current optical semi-automatic titrator built on the principle of the reflectance spectrometry could be successfully used even for the determination of the end of the end point in the precipitation titration where the solid particles are formed during the titration process, it was found to be feasible that a completely automated optical titrator would be designed and built based on the current findings

  13. Investigations on the photoreactions of phenothiazine and phenoxazine in presence of 9-cyanoanthracene by using steady state and time resolved spectroscopic techniques.

    Science.gov (United States)

    Bardhan, Munmun; Mandal, Paulami; Tzeng, Wen-Bih; Ganguly, Tapan

    2010-09-01

    By using electrochemical, steady state and time resolved (fluorescence lifetime and transient absorption) spectroscopic techniques, detailed investigations were made to reveal the mechanisms of charge separation or forward electron transfer reactions within the electron donor phenothiazine (PTZH) or phenoxazine (PXZH) and well known electron acceptor 9-cyanoanthracene (CNA). The transient absorption spectra suggest that the charge separated species formed in the excited singlet state resulted from intermolecular photoinduced electron transfer reactions within the donor PTZH (or PXZH) and CNA acceptor relaxes to the corresponding triplet state. Though alternative mechanisms of via formations of contact neutral radical by H-transfer reaction have been proposed but the observed results obtained from the time resolved measurements indicate that the regeneration of ground state reactants is primarily responsible due to direct recombination of triplet contact ion-pair (CIP) or solvent-separated ion-pair (SSIP).

  14. Determination of Pu Oxidation states in the HCl Media Using with UV-Visible Absorption Spectroscopic Techniques

    International Nuclear Information System (INIS)

    Lee, Myung Ho; Suh, Mu Yeol; Park, Kyoung Kyun; Park, Yeong Jae; Kim, Won Ho

    2006-01-01

    The spectroscopic characteristics of Pu (III, IV, V, VI) in the HCl media were investigated by measuring Pu oxidation states using a UV-Vis-NIR spectrophotometer (400-1200 nm) after adjusting Pu oxidation states with oxidation/reduction reagents. Pu in stock solution was reduced to Pu(III) with NH 2 OH · HCl, and oxidized to Pu(IV) and Pu(VI) with NaNO 2 and HCIO 4 , respectively. Also, Pu(V) was adjusted in the Pu(VI) solution with NH 2 OH · HCl. The major absorption peaks of Pu (IV) and Pu(III) were measured in the 470 nm and 600 nm, respectively. The major absorption peaks of Pu (VI) and Pu(V) were measured in the 830 nm and 1135 nm, respectively. There was not found to be significant changes of UV-V is absorption spectra for Pu(III), Pu(IV) and Pu(VI) with aging time, except that an unstable Pu(V) immediately reduced to Pu(III).

  15. Determination of photocarrier density under continuous photoirradiation using spectroscopic techniques as applied to polymer: Fullerene blend films

    Energy Technology Data Exchange (ETDEWEB)

    Kanemoto, Katsuichi, E-mail: kkane@sci.osaka-cu.ac.jp; Nakatani, Hitomi; Domoto, Shinya [Department of Physics, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585 (Japan)

    2014-10-28

    We propose a method to determine the density of photocarrier under continuous photoirradiation in conjugated polymers using spectroscopic signals obtained by photoinduced absorption (PIA) measurements. The bleaching signals in the PIA measurements of polymer films and the steady-state absorption signals of oxidized polymer solution are employed to determine the photocarrier density. The method is applied to photocarriers of poly (3-hexylthiophene) (P3HT) in a blended film consisting of P3HT and [6,6]-phenyl C61 butyric acid methyl ester (PCBM). The photocarrier density under continuous photoirradiation of 580 mW/cm{sup 2} is determined to be 3.5 × 10{sup 16 }cm{sup −3}. Using a trend of the carrier density increasing in proportion to the square root of photo-excitation intensity, we provide a general formula to estimate the photocarrier density under simulated 1 sun solar irradiation for the P3HT: PCBM film of an arbitrary thickness. We emphasize that the method proposed in this study enables an estimate of carrier density without measuring a current and can be applied to films with no electrodes as well as to devices.

  16. Development of quality control and instrumentation performance metrics for diffuse optical spectroscopic imaging instruments in the multi-center clinical environment

    Science.gov (United States)

    Keene, Samuel T.; Cerussi, Albert E.; Warren, Robert V.; Hill, Brian; Roblyer, Darren; Leproux, AnaÑ--s.; Durkin, Amanda F.; O'Sullivan, Thomas D.; Haghany, Hosain; Mantulin, William W.; Tromberg, Bruce J.

    2013-03-01

    Instrument equivalence and quality control are critical elements of multi-center clinical trials. We currently have five identical Diffuse Optical Spectroscopic Imaging (DOSI) instruments enrolled in the American College of Radiology Imaging Network (ACRIN, #6691) trial located at five academic clinical research sites in the US. The goal of the study is to predict the response of breast tumors to neoadjuvant chemotherapy in 60 patients. In order to reliably compare DOSI measurements across different instruments, operators and sites, we must be confident that the data quality is comparable. We require objective and reliable methods for identifying, correcting, and rejecting low quality data. To achieve this goal, we developed and tested an automated quality control algorithm that rejects data points below the instrument noise floor, improves tissue optical property recovery, and outputs a detailed data quality report. Using a new protocol for obtaining dark-noise data, we applied the algorithm to ACRIN patient data and successfully improved the quality of recovered physiological data in some cases.

  17. THE REST-FRAME OPTICAL SPECTROSCOPIC PROPERTIES OF LY α -EMITTERS AT z  ∼ 2.5: THE PHYSICAL ORIGINS OF STRONG LY α EMISSION

    Energy Technology Data Exchange (ETDEWEB)

    Trainor, Ryan F. [Department of Astronomy, University of California, Berkeley, 501 Campbell Hall, Berkeley, CA 94720 (United States); Strom, Allison L.; Steidel, Charles C. [Cahill Center for Astrophysics, MC 249-17, 1200 E California Boulevard, Pasadena, CA 91125 (United States); Rudie, Gwen C., E-mail: trainor@berkeley.edu [Carnegie Observatories, 813 Santa Barbara Street, Pasadena, CA 91101 (United States)

    2016-12-01

    We present the rest-frame optical spectroscopic properties of 60 faint ( R {sub AB} ∼ 27; L ∼ 0.1 L {sub *}) Ly α -selected galaxies (LAEs) at z  ≈ 2.56. These LAEs also have rest-UV spectra of their Ly α emission line morphologies, which trace the effects of interstellar and circumgalactic gas on the escape of Ly α photons. We find that the LAEs have diverse rest-optical spectra, but their average spectroscopic properties are broadly consistent with the extreme low-metallicity end of the populations of continuum-selected galaxies selected at z  ≈ 2–3. In particular, the LAEs have extremely high [O iii] λ 5008/H β ratios (log([O iii]/H β ) ∼ 0.8) and low [N ii] λ 6585/H α ratios (log([N ii]/H α ) < 1.15). Coupled with a detection of the [O iii] λ 4364 auroral line, these measurements indicate that the star-forming regions in faint LAEs are characterized by high electron temperatures (T{sub e} ≈ 1.8 × 10{sup 4} K), low oxygen abundances (12 + log(O/H) ≈ 8.04, Z{sub neb} ≈ 0.22 Z {sub ⊙}), and high excitations with respect to their more luminous continuum-selected analogs. Several of our faintest LAEs have line ratios consistent with even lower metallicities, including six with 12 + log(O/H) ≈ 6.9–7.4 (Z {sub neb} ≈ 0.02–0.05 Z{sub ⊙}). We interpret these observations in light of new models of stellar evolution (including binary interactions) that have been shown to produce long-lived populations of hot, massive stars at low metallicities. We find that strong, hard ionizing continua are required to reproduce our observed line ratios, suggesting that faint galaxies are efficient producers of ionizing photons and important analogs of reionization-era galaxies. Furthermore, we investigate the physical trends accompanying Ly α emission across the largest current sample of combined Ly α and rest-optical galaxy spectroscopy, including both the 60 KBSS-Ly α LAEs and 368 more luminous galaxies at similar redshifts. We

  18. Proposal to develop techniques using magneto-optic and electro-optic effects in optical fiber for CTR diagnostics

    International Nuclear Information System (INIS)

    Chandler, G.I.; Jahoda, F.C.

    1982-02-01

    We discuss the developing technology of measuring electric and magnetic fields with optical fibers using the Faraday and Kerr effects, magnetostriction, and Sagnac interferometry. We review the measurement of induced birefringence in the presence of natural birefringence. We propose the use of these effects in making measurements in the fusion research program, with ZT-40 as an example

  19. Spectroscopic studies of resonant coupling of silver optical antenna arrays to a near-surface quantum well

    International Nuclear Information System (INIS)

    Gehl, Michael; Zandbergen, Sander; Gibson, Ricky; Nader, Nima; Sears, Jasmine; Keiffer, Patrick; Khitrova, Galina; Béchu, Muriel; Wegener, Martin; Hendrickson, Joshua

    2014-01-01

    The coupling of radiation emitted on semiconductor inter-band transitions to resonant optical-antenna arrays allows for enhanced light–matter interaction via the Purcell effect. Semiconductor optical gain also potentially allows for loss reduction in metamaterials. Here we extend our previous work on optically pumped individual near-surface InGaAs quantum wells coupled to silver split-ring-resonator arrays to wire and square-antenna arrays. By comparing the transient pump-probe experimental results with the predictions of a simple model, we find that the effective coupling is strongest for the split rings, even though the split rings have the weakest dipole moment. The effect of the latter must thus be overcompensated by a smaller effective mode volume of the split rings. Furthermore, we also present a systematic variation of the pump-pulse energy, which was fixed in our previous experiments. (paper)

  20. Raman and IR spectroscopic structural characterization of LiAlO2 powders prepared using a liquid mix technique

    International Nuclear Information System (INIS)

    Cornilsen, B.C.; Loyselle, P.L.; Saporta, J.D.

    1990-01-01

    γ-LiAlO 2 and β-LiAlO 2 have been characterized using Raman and infrared spectroscopy. Powders have been prepared using two different preparation techniques: a solution method known as the liquid mix technique (LMT) and the traditional ceramic method. The authors find that the LMT allows direct production of single phase γ-LiAlO 2 at 600 degrees C, below that found using other preparation methods. Furthermore, this solution technique appears to avoid formation of the β-LiAlO 2 intermediate phase. At lower temperatures, the LMT product is a disordered precursor of γ- LiAlO 2

  1. Multistage bioassociation of uranium onto an extremely halophilic archaeon revealed by a unique combination of spectroscopic and microscopic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Bader, Miriam; Müller, Katharina; Foerstendorf, Harald; Drobot, Björn [Helmholtz-Zentrum Dresden – Rossendorf, Institute of Resource Ecology, Bautzner Landstraße 400, 01328 Dresden (Germany); Schmidt, Matthias; Musat, Niculina [Helmholtz Centre for Environmental Research–UFZ, Department of Isotope Biogeochemistry, Permoserstraße 15, 04318 Leipzig (Germany); Swanson, Juliet S.; Reed, Donald T. [Los Alamos National Laboratory, Repository Science and Operations, 1400 University Drive, Carlsbad, NM, 88220 (United States); Stumpf, Thorsten [Helmholtz-Zentrum Dresden – Rossendorf, Institute of Resource Ecology, Bautzner Landstraße 400, 01328 Dresden (Germany); Cherkouk, Andrea, E-mail: a.cherkouk@hzdr.de [Helmholtz-Zentrum Dresden – Rossendorf, Institute of Resource Ecology, Bautzner Landstraße 400, 01328 Dresden (Germany)

    2017-04-05

    Highlights: • First prolonged kinetics study of uranium to halophilic archaea was performed. • An atypical time-dependent bioassociation behavior of uranium was observed. • Unique combination of spectroscopic and microscopic methods was used. • In situ ATR FT-IR showed association of U(VI) to phosphoryl and carboxylate groups. • Time-dependent changes of U(VI) localization could be monitored by SEM/EDX. - Abstract: The interactions of two extremely halophilic archaea with uranium were investigated at high ionic strength as a function of time, pH and uranium concentration. Halobacterium noricense DSM-15987 and Halobacterium sp. putatively noricense, isolated from the Waste Isolation Pilot Plant repository, were used for these investigations. The kinetics of U(VI) bioassociation with both strains showed an atypical multistage behavior, meaning that after an initial phase of U(VI) sorption, an unexpected interim period of U(VI) release was observed, followed by a slow reassociation of uranium with the cells. By applying in situ attenuated total reflection Fourier-transform infrared spectroscopy, the involvement of phosphoryl and carboxylate groups in U(VI) complexation during the first biosorption phase was shown. Differences in cell morphology and uranium localization become visible at different stages of the bioassociation process, as shown with scanning electron microscopy in combination with energy dispersive X-ray spectroscopy. Our results demonstrate for the first time that association of uranium with the extremely halophilic archaeon is a multistage process, beginning with sorption and followed by another process, probably biomineralization.

  2. Multistage bioassociation of uranium onto an extremely halophilic archaeon revealed by a unique combination of spectroscopic and microscopic techniques

    International Nuclear Information System (INIS)

    Bader, Miriam; Müller, Katharina; Foerstendorf, Harald; Drobot, Björn; Schmidt, Matthias; Musat, Niculina; Swanson, Juliet S.; Reed, Donald T.; Stumpf, Thorsten; Cherkouk, Andrea

    2017-01-01

    Highlights: • First prolonged kinetics study of uranium to halophilic archaea was performed. • An atypical time-dependent bioassociation behavior of uranium was observed. • Unique combination of spectroscopic and microscopic methods was used. • In situ ATR FT-IR showed association of U(VI) to phosphoryl and carboxylate groups. • Time-dependent changes of U(VI) localization could be monitored by SEM/EDX. - Abstract: The interactions of two extremely halophilic archaea with uranium were investigated at high ionic strength as a function of time, pH and uranium concentration. Halobacterium noricense DSM-15987 and Halobacterium sp. putatively noricense, isolated from the Waste Isolation Pilot Plant repository, were used for these investigations. The kinetics of U(VI) bioassociation with both strains showed an atypical multistage behavior, meaning that after an initial phase of U(VI) sorption, an unexpected interim period of U(VI) release was observed, followed by a slow reassociation of uranium with the cells. By applying in situ attenuated total reflection Fourier-transform infrared spectroscopy, the involvement of phosphoryl and carboxylate groups in U(VI) complexation during the first biosorption phase was shown. Differences in cell morphology and uranium localization become visible at different stages of the bioassociation process, as shown with scanning electron microscopy in combination with energy dispersive X-ray spectroscopy. Our results demonstrate for the first time that association of uranium with the extremely halophilic archaeon is a multistage process, beginning with sorption and followed by another process, probably biomineralization.

  3. 3-D optical profilometry at micron scale with multi-frequency fringe projection using modified fibre optic Lloyd's mirror technique

    Science.gov (United States)

    Inanç, Arda; Kösoğlu, Gülşen; Yüksel, Heba; Naci Inci, Mehmet

    2018-06-01

    A new fibre optic Lloyd's mirror method is developed for extracting 3-D height distribution of various objects at the micron scale with a resolution of 4 μm. The fibre optic assembly is elegantly integrated to an optical microscope and a CCD camera. It is demonstrated that the proposed technique is quite suitable and practical to produce an interference pattern with an adjustable frequency. By increasing the distance between the fibre and the mirror with a micrometre stage in the Lloyd's mirror assembly, the separation between the two bright fringes is lowered down to the micron scale without using any additional elements as part of the optical projection unit. A fibre optic cable, whose polymer jacket is partially stripped, and a microfluidic channel are used as test objects to extract their surface topographies. Point by point sensitivity of the method is found to be around 8 μm, changing a couple of microns depending on the fringe frequency and the measured height. A straightforward calibration procedure for the phase to height conversion is also introduced by making use of the vertical moving stage of the optical microscope. The phase analysis of the acquired image is carried out by One Dimensional Continuous Wavelet Transform for which the chosen wavelet is the Morlet wavelet and the carrier removal of the projected fringe patterns is achieved by reference subtraction. Furthermore, flexible multi-frequency property of the proposed method allows measuring discontinuous heights where there are phase ambiguities like 2π by lowering the fringe frequency and eliminating the phase ambiguity.

  4. Simultaneous PIV and pulsed shadow technique in slug flow: a solution for optical problems

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, S. [Karman Institute for Fluid Dynamics, Chaussee de Waterloo 72, B-1640, Rhode Saint Genese (Belgium); Centro de Estudos de Fenomenos de Transporte, Departamento de Eng. Quimica, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, 4200-465, Porto (Portugal); Sousa, R.G.; Pinto, A.M.F.R.; Campos, J.B.L.M. [Centro de Estudos de Fenomenos de Transporte, Departamento de Eng. Quimica, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, 4200-465, Porto (Portugal); Riethmuller, M.L. [Karman Institute for Fluid Dynamics, Chaussee de Waterloo 72, B-1640, Rhode Saint Genese (Belgium)

    2003-12-01

    A recent technique of simultaneous particle image velocimetry (PIV) and pulsed shadow technique (PST) measurements, using only one black and white CCD camera, is successfully applied to the study of slug flow. The experimental facility and the operating principle are described. The technique is applied to study the liquid flow pattern around individual Taylor bubbles rising in an aqueous solution of glycerol with a dynamic viscosity of 113 x 10{sup -3} Pa s. With this technique the optical perturbations found in PIV measurements at the bubble interface are completely solved in the nose and in annular liquid film regions as well as in the rear of the bubble for cases in which the bottom is flat. However, for Taylor bubbles with concave oblate bottoms, some optical distortions appear and are discussed. The measurements achieved a spatial resolution of 0.0022 tube diameters. The results reported show high precision and are in agreement with theoretical and experimental published data. (orig.)

  5. Beam shaping optics to enhance performance of interferometry techniques in grating manufacture

    Science.gov (United States)

    Laskin, Alexander; Laskin, Vadim; Ostrun, Aleksei

    2018-02-01

    Improving of industrial holographic and interferometry techniques is of great importance in interference lithography, computer-generated holography, holographic data storage, interferometry recording of Bragg gratings as well as gratings of various types in semiconductor industry. Performance of mentioned techniques is essentially enhanced by providing a light beam with flat phase front and flat-top irradiance distribution. Therefore, transformation of Gaussian distribution of a TEM00 laser to flat-top (top hat, uniform) distribution is an important optical task. There are different refractive and diffractive beam shaping approaches used in laser industrial and scientific applications, but only few of them are capable to fulfil the optimum conditions for beam quality demanding holography and interferometry. As a solution it is suggested to apply refractive field mapping beam shaping optics πShaper, which operational principle presumes almost lossless transformation of Gaussian to flat-top beam with flatness of output wavefront, conserving of beam consistency, providing collimated low divergent output beam, high transmittance, extended depth of field, negligible wave aberration, and achromatic design provides capability to work with several lasers with different wavelengths simultaneously. High optical quality of resulting flat-top beam allows applying additional optical components to build various imaging optical systems for variation of beam size and shape to fulfil requirements of a particular application. This paper will describe design basics of refractive beam shapers and optical layouts of their applying in holography and laser interference lithography. Examples of real implementations and experimental results will be presented as well.

  6. Coherent optical adaptive technique improves the spatial resolution of STED microscopy in thick samples

    Science.gov (United States)

    Yan, Wei; Yang, Yanlong; Tan, Yu; Chen, Xun; Li, Yang; Qu, Junle; Ye, Tong

    2018-01-01

    Stimulated emission depletion microscopy (STED) is one of far-field optical microscopy techniques that can provide sub-diffraction spatial resolution. The spatial resolution of the STED microscopy is determined by the specially engineered beam profile of the depletion beam and its power. However, the beam profile of the depletion beam may be distorted due to aberrations of optical systems and inhomogeneity of specimens’ optical properties, resulting in a compromised spatial resolution. The situation gets deteriorated when thick samples are imaged. In the worst case, the sever distortion of the depletion beam profile may cause complete loss of the super resolution effect no matter how much depletion power is applied to specimens. Previously several adaptive optics approaches have been explored to compensate aberrations of systems and specimens. However, it is hard to correct the complicated high-order optical aberrations of specimens. In this report, we demonstrate that the complicated distorted wavefront from a thick phantom sample can be measured by using the coherent optical adaptive technique (COAT). The full correction can effectively maintain and improve the spatial resolution in imaging thick samples. PMID:29400356

  7. Application of a distributed optical fiber sensing technique in monitoring the stress of precast piles

    International Nuclear Information System (INIS)

    Lu, Y; Shi, B; Wei, G Q; Zhang, D; Chen, S E

    2012-01-01

    Due to its ability in providing long distance, distributed sensing, the optical fiber sensing technique based on a Brillouin optical time domain reflectometer (BOTDR) has a unique advantage in monitoring the stability and safety of linear structures. This paper describes the application of a BOTDR-based technique to measure the stress within precast piles. The principle behind the BOTDR and the embedding technique for the sensing optical fiber in precast piles is first introduced, and then the analysis method and deformation and stress calculation based on distributed strain data are given. Finally, a methodology for using a BOTDR-based monitoring workflow for in situ monitoring of precast piles, combined with a practical example, is introduced. The methodology requires implantation of optical fibers prior to pile placement. Field experimental results show that the optical fiber implantation method with slotting, embedding, pasting and jointing is feasible, and have accurately measured the axial force, side friction, end-bearing resistance and bearing feature of the precast pile according to the strain measuring data. (paper)

  8. Using a novel spectroscopic reflectometer to optimize a radiation-hardened submicron silicon-on-sapphire CMOS process

    International Nuclear Information System (INIS)

    Do, N.T.; Zawaideh, E.; Vu, T.Q.; Warren, G.; Mead, D.; Do, N.T.; Li, G.P.; Tsai, C.S.

    1999-01-01

    A radiation-hardened sub-micron silicon-on-sapphire CMOS process is monitored and optimized using a novel optical technique based on spectroscopic reflectometry. Quantitative measurements of the crystal quality, surface roughness, and device radiation hardness show excellent correlation between this technique and the Atomic Force Microscopy. (authors)

  9. Photopyroelectric Techniques for thermo-optical characterization of gold nano-particles

    International Nuclear Information System (INIS)

    Chávez-Sandoval, B E; Balderas-López, J A; Padilla-Bernal, G; Moreno-Rivera, M A; Franco-Hernández, M O; Martínez-Jiménez, A; García-Franco, F

    2015-01-01

    Since the first methodology, proposed by Turkevich, to produce gold nanoparticles (AuNPs), improvements have been made as to allow better controllability in their size and shape. These two parameters play important role for application of gold nanoparticles since they determine their optical and thermal properties. Two photopyroelectric techniques for the measurement of the thermal diffusivity and the optical absorption coefficient for nano-particles are introduced. These thermo-physical properties were measured for the colloidal systems at different nano-particle's sizes and, for optical properties, at three different wavelengths (405 nm, 488 nm and 532 nm). No significant difference, on thermal properties, was found in the range of nano-particles' sizes studied in this work; in opposition optical properties shown more sensitive to this parameter

  10. Reconstruction of elongated bubbles fusing the information from multiple optical probes through a Bayesian inference technique

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Shubhankar; Das, Prasanta Kr., E-mail: pkd@mech.iitkgp.ernet.in [Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302 (India); Roy Chaudhuri, Partha [Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302 (India)

    2016-07-15

    In this communication, a novel optical technique has been proposed for the reconstruction of the shape of a Taylor bubble using measurements from multiple arrays of optical sensors. The deviation of an optical beam passing through the bubble depends on the contour of bubble surface. A theoretical model of the deviation of a beam during the traverse of a Taylor bubble through it has been developed. Using this model and the time history of the deviation captured by the sensor array, the bubble shape has been reconstructed. The reconstruction has been performed using an inverse algorithm based on Bayesian inference technique and Markov chain Monte Carlo sampling algorithm. The reconstructed nose shape has been compared with the true shape, extracted through image processing of high speed images. Finally, an error analysis has been performed to pinpoint the sources of the errors.

  11. Measurement of morphing wing deflection by a cross-coherence fiber optic interferometric technique

    Science.gov (United States)

    Tomić, Miloš C.; Djinović, Zoran V.; Scheerer, Michael; Petricevic, Slobodan J.

    2018-01-01

    A fiber-optic interferometric technique aimed at measuring the deflection of aircrafts’ morphing wings is presented. The wing deflection induces a strain in the sensing fiber optic coils that are firmly fixed onto the wing. A change of the phase angle of the light propagating through the fiber is measured by an ‘all-in-fiber’ Michelson interferometer based on a 3 × 3 fiber-optic coupler. Two light sources of different coherence lengths and wavelengths are simultaneously used to ensure a wide measurement range and high accuracy. A new technique for determination of the zero deflection point using the cross-correlation of the two interferograms is proposed. The experiments performed on a specimen made of a carbon-fiber-reinforced plastic honeycomb structure demonstrated a relative uncertainty morphing wing deflection.

  12. Multiple-output all-optical header processing technique based on two-pulse correlation principle

    NARCIS (Netherlands)

    Calabretta, N.; Liu, Y.; Waardt, de H.; Hill, M.T.; Khoe, G.D.; Dorren, H.J.S.

    2001-01-01

    A serial all-optical header processing technique based on a two-pulse correlation principle in a semiconductor laser amplifier in a loop mirror (SLALOM) configuration that can have a large number of output ports is presented. The operation is demonstrated experimentally at a 10Gbit/s Manchester

  13. Application condition of optical communication technique in the nuclear power plants

    International Nuclear Information System (INIS)

    Sakurai, Jun

    1999-01-01

    As the optical communication technique can process rapidly a lot of information and exclude perfectly error action due to noise, it is adopted gradually to commercial and company communications (containing operational managements in large scale facilities) in worldwide scale in stead of conventional communication technique (containing operational controls and measurements). In application to the nuclear power plants, as forming not only change in properties but also deterioration due to radiation damage in many cases of exposure to various types of radiations such as neutron, gamma-ray, and so forth in difference with conventional using environment, its using range is limited at present. In future, development of optical fibers or elements with excellent high temperature and radiation resistances usable stably at reactor core for a long time is essential. The regular application of the optical communication technique at the nuclear power plants begins just now, which is an expected field for future large development. And, for the old nuclear power plant in present operation, substitution to the optical communication technique in accompany with replace of appliances at periodical inspections will also be conducted. Its response is already required rapidly in the Tokyo Electric Power Co., Ltd.. (G.K.)

  14. Low power excitation of gyrotron-type modes in cylindrical waveguide using quasi-optical techniques

    International Nuclear Information System (INIS)

    Alexandrov, N.L.; Whaley, D.R.; Tran, M.Q.; Denisov, D.R.

    1995-03-01

    Experimental results of low power excitation of a 118 GHz TE 22,6 rotating mode are presented. A rectangular mode is converted to a TE 22,6 circular waveguide using quasi-optical techniques. A good conversion efficiency is measured and the experimentally observed field intensity profiles show the percentage of unwanted modes to be small. (author) 10 figs., 10 refs

  15. Optical spectroscopy techniques can accurately distinguish benign and malignant renal tumours.

    Science.gov (United States)

    Couapel, Jean-Philippe; Senhadji, Lotfi; Rioux-Leclercq, Nathalie; Verhoest, Grégory; Lavastre, Olivier; de Crevoisier, Renaud; Bensalah, Karim

    2013-05-01

    WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: There is little known about optical spectroscopy techniques ability to evaluate renal tumours. This study shows for the first time the ability of Raman and optical reflectance spectroscopy to distinguish benign and malignant renal tumours in an ex vivo environment. We plan to develop this optical assistance in the operating room in the near future. To evaluate the ability of Raman spectroscopy (RS) and optical reflectance spectroscopy (ORS) to distinguish benign and malignant renal tumours at surgery. Between March and October 2011, RS and ORS spectra were prospectively acquired on surgical renal specimens removed for suspicion of renal cell carcinoma (RCC). Optical measurements were done immediately after surgery. Optical signals were normalised to ensure comparison between spectra. Initial and final portions of each spectrum were removed to avoid artefacts. A support vector machine (SVM) was built and tested using a leave-one-out cross-validation. Classification scores, including accuracy, sensitivity and specificity were calculated on the entire population and in patients with tumours of 700 optical spectra were obtained and submitted to SVM classification. The SVM could recognise benign and malignant renal tumours with an accuracy of 96% (RS) and 88% (ORS) in the whole population and with an accuracy of 93% (RS) and 95% (ORS) in the present subset of small renal tumours (Benign and malignant renal tumours can be accurately discriminated by a combination of RS and ORS. In vivo experiments are needed to further assess the value of optical spectroscopy techniques. © 2012 BJU International.

  16. Astrophysical techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kitchin, C R

    1984-01-01

    The subject is covered in chapters, entitled: detectors (optical and infrared detection; radio and microwave detection; X-ray and gamma-ray detection; cosmic ray detectors; neutrino detectors; gravitational radiation); imaging (photography; electronic imaging; scanning; interferometry; speckle interferometry; occultations; radar); photometry and photometers; spectroscopy and spectroscopes; other techniques (astrometry; polarimetry; solar studies; magnetometry). Appendices: magnitudes and spectral types of bright stars; north polar sequence; standard stars for the UBV photometric system; standard stars for the UVBY photometric system; standard stars for MK spectral types; standard stars for polarimetry; Julian date; catalogues; answers to the exercises.

  17. Synthesis and electrical, spectroscopic and nonlinear optical properties of cobalt molecular materials obtained from PcCo(CN)L (L = ethylenediamine, 1,4-diaminebutane, 1,12-diaminododecane and 2,6-diamineanthraquinone)

    Energy Technology Data Exchange (ETDEWEB)

    Morales-Saavedra, O.G., E-mail: omar.morales@ccadet.unam.mx [Lab. of Nonlinear Optics, Centro de Ciencias Aplicadas y Desarrollo Tecnologico, Universidad Nacional Autonoma de Mexico, CCADET-UNAM, Apdo, Postal 70-186, C.P. 04510 Coyoacan, Cd. Universitaria, Mexico D. F. (Mexico); Sanchez-Vergara, M.E. [Coordinacion de Ingenieria Mecatronica, Facultad de Ingenieria, Universidad Anahuac del Norte, Avenida Universidad Anahuac 46, Col. Lomas Anahuac, 52786 Huixquilucan, Estado de Mexico (Mexico); Rodriguez-Rosales, A.A.; Ortega-Martinez, R. [Lab. of Nonlinear Optics, Centro de Ciencias Aplicadas y Desarrollo Tecnologico, Universidad Nacional Autonoma de Mexico, CCADET-UNAM, Apdo, Postal 70-186, C.P. 04510 Coyoacan, Cd. Universitaria, Mexico D. F. (Mexico); Ortiz-Rebollo, A. [Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, IIM-UNAM, A.P. 70-360 Coyoacan, 04510 Mexico D. F. (Mexico); Frontana-Uribe, B.A. [Centro Conjunto de Investigacion en Quimica Sustentable UAEM-UNAM Km. 14.5, Carretera Toluca-Atlacomulco, C.P. 50200 Toluca, Estado de Mexico (Mexico); Garcia-Montalvo, V. [Instituto de Quimica, Universidad Nacional Autonoma de Mexico, Circuito Exterior, Ciudad Universitaria, Mexico D. F. 04510 (Mexico)

    2010-10-01

    Novel PcCo(CN)L monomeric complexes were synthesized from [PcCoCN]{sub n} compounds and bidentate axial ligands (L) such as ethylenediamine, 1,4-diaminebutane, 1,12-diaminedodecane and 2,6-diamineanthraquinone. These complexes were implemented to fabricate pellets and thin films by the vacuum thermal evaporation technique. The obtained compounds and deposited thin films were characterized by different spectroscopic techniques. Measurements of the electrical conductivity and the electrical current as a function of temperature were also carried out. IR-spectroscopy studies showed that the ligand attaches to the [PcCoCN]{sub n} unit. The C=N vibrational band is found in the PcCo(et)CN and PcCo(bu)CN molecular solids, although it is displaced with respect to other reported values. Compounds PcCo(do){sub 2} and PcCo(an){sub 2} do not show C=N vibrational bands. This fact suggests a double bond between the ligand and the macrocycle and a coordination at the fifth and sixth position on the Co(III) atom. UV-vis spectra of the thin films exhibited higher conjugation degree for the CN-based samples. Electrical conductivity for the PcCo(an){sub 2} complex was consistently low for all temperature ranges under measurement, whereas the other synthesized compounds showed a semiconductor-like dependence of electric current with temperature. Additionally, cubic nonlinear optical (NLO) characterizations of the film samples were performed with the Z-Scan and third harmonic generation (THG) techniques, all samples exhibit outstandingly high nonlinear activity.

  18. Synthesis and electrical, spectroscopic and nonlinear optical properties of cobalt molecular materials obtained from PcCo(CN)L (L = ethylenediamine, 1,4-diaminebutane, 1,12-diaminododecane and 2,6-diamineanthraquinone)

    International Nuclear Information System (INIS)

    Morales-Saavedra, O.G.; Sanchez-Vergara, M.E.; Rodriguez-Rosales, A.A.; Ortega-Martinez, R.; Ortiz-Rebollo, A.; Frontana-Uribe, B.A.; Garcia-Montalvo, V.

    2010-01-01

    Novel PcCo(CN)L monomeric complexes were synthesized from [PcCoCN] n compounds and bidentate axial ligands (L) such as ethylenediamine, 1,4-diaminebutane, 1,12-diaminedodecane and 2,6-diamineanthraquinone. These complexes were implemented to fabricate pellets and thin films by the vacuum thermal evaporation technique. The obtained compounds and deposited thin films were characterized by different spectroscopic techniques. Measurements of the electrical conductivity and the electrical current as a function of temperature were also carried out. IR-spectroscopy studies showed that the ligand attaches to the [PcCoCN] n unit. The C=N vibrational band is found in the PcCo(et)CN and PcCo(bu)CN molecular solids, although it is displaced with respect to other reported values. Compounds PcCo(do) 2 and PcCo(an) 2 do not show C=N vibrational bands. This fact suggests a double bond between the ligand and the macrocycle and a coordination at the fifth and sixth position on the Co(III) atom. UV-vis spectra of the thin films exhibited higher conjugation degree for the CN-based samples. Electrical conductivity for the PcCo(an) 2 complex was consistently low for all temperature ranges under measurement, whereas the other synthesized compounds showed a semiconductor-like dependence of electric current with temperature. Additionally, cubic nonlinear optical (NLO) characterizations of the film samples were performed with the Z-Scan and third harmonic generation (THG) techniques, all samples exhibit outstandingly high nonlinear activity.

  19. Structural, vibrational spectroscopic and nonlinear optical activity studies on 2-hydroxy- 3, 5-dinitropyridine: A DFT approach

    Science.gov (United States)

    Asath, R. Mohamed; Premkumar, S.; Jawahar, A.; Mathavan, T.; Dhas, M. Kumara; Benial, A. Milton Franklin

    2015-06-01

    The conformational analysis was carried out for 2-Hydroxy- 3, 5-dinitropyridine molecule using potential energy surface scan and the most stable optimized conformer was predicted. The vibrational frequencies and Mulliken atomic charge distribution were calculated for the optimized geometry of the molecule using DFT/B3LYP cc-pVQZ basis set by Gaussian 09 Program. The vibrational frequencies were assigned on the basis of potential energy distribution calculation using VEDA 4.0 program. In the Frontier molecular orbitals analysis, the molecular reactivity, kinetic stability, intramolecular charge transfer studies and the calculation of ionization energy, electron affinity, global hardness, chemical potential, electrophilicity index and softness values of the title molecule were carried out. The nonlinear optical activity of the molecule was studied by means of first order hyperpolarizability, which was computed as 7.64 times greater than urea. The natural bond orbital analysis was performed to confirm the nonlinear optical activity of the molecule.

  20. Thermal, spectroscopic and laser properties of Nd3+ in gadolinium scandium gallium garnet crystal produced by optical floating zone method

    Science.gov (United States)

    Tian, Li; Wang, Shuxian; Wu, Kui; Wang, Baolin; Yu, Haohai; Zhang, Huaijin; Cai, Huaqiang; Huang, Hui

    2013-12-01

    A neodymium-doped gadolinium scandium gallium garnet (Nd:GSGG) single crystal with dimensions of Φ 5 × 20 mm2 has been grown by means of optical floating zone (OFZ). X-ray powder diffraction (XRPD) result shows that the as-grown Nd:GSGG crystal possesses a cubic structure with space group Ia3d and a cell parameter of a = 1.2561 nm. Effective elemental segregation coefficients of the Nd:GSGG as-grown crystal were calculated by using X-ray fluorescence (XRF). The thermal properties of the Nd:GSGG crystal were systematically studied by measuring the specific heat, thermal expansion and thermal diffusion coefficient, and the thermal conductivity of this crystal was calculated. The absorption and luminescence spectra of Nd:GSGG were measured at room temperature (RT). By using the Judd-Ofelt (J-O) theory, the theoretical radiative lifetime was calculated and compared with the experimental result. Continuous wave (CW) laser performance was achieved with the Nd:GSGG at the wavelength of 1062 nm when it was pumped by a laser diode (LD). A maximum output power of 0.792 W at 1062 nm was obtained with a slope efficiency of 11.89% under a pump power of 7.36 W, and an optical-optical conversion efficiency of 11.72%.

  1. Design refinement of multilayer optical thin film devices with two optimization techniques

    International Nuclear Information System (INIS)

    Apparao, K.V.S.R.

    1992-01-01

    The design efficiency of two different optimization techniques of designing multilayer optical thin film devices is compared. Ten different devices of varying complexities are chosen as design examples for the comparison. The design refinement efficiency and the design parameter characteristics of all the sample designs obtained with the two techniques are compared. The results of the comparison demonstrate that the new method of design developed using damped least squares technique with indirect derivatives give superior and efficient designs compared to the method developed with direct derivatives. (author). 23 refs., 4 tabs., 14 figs

  2. Exploring machine-learning-based control plane intrusion detection techniques in software defined optical networks

    Science.gov (United States)

    Zhang, Huibin; Wang, Yuqiao; Chen, Haoran; Zhao, Yongli; Zhang, Jie

    2017-12-01

    In software defined optical networks (SDON), the centralized control plane may encounter numerous intrusion threatens which compromise the security level of provisioned services. In this paper, the issue of control plane security is studied and two machine-learning-based control plane intrusion detection techniques are proposed for SDON with properly selected features such as bandwidth, route length, etc. We validate the feasibility and efficiency of the proposed techniques by simulations. Results show an accuracy of 83% for intrusion detection can be achieved with the proposed machine-learning-based control plane intrusion detection techniques.

  3. A combined experimental and computational study of 3-bromo-5-(2,5-difluorophenyl) pyridine and 3,5-bis(naphthalen-1-yl)pyridine: Insight into the synthesis, spectroscopic, single crystal XRD, electronic, nonlinear optical and biological properties

    Science.gov (United States)

    Ghiasuddin; Akram, Muhammad; Adeel, Muhammad; Khalid, Muhammad; Tahir, Muhammad Nawaz; Khan, Muhammad Usman; Asghar, Muhammad Adnan; Ullah, Malik Aman; Iqbal, Muhammad

    2018-05-01

    Carbon-carbon coupling play a vital role in the synthetic field of organic chemistry. Two novel pyridine derivatives: 3-bromo-5-(2,5-difluorophenyl)pyridine (1) and 3,5-bis(naphthalen-1-yl)pyridine (2) were synthesized via carbon-carbon coupling, characterized by XRD, spectroscopic techniques and also investigated by using density functional theory (DFT). XRD data and optimized DFT studies are found to be in good correspondence with each other. The UV-Vis analysis of compounds under study i.e. (1) and (2) was obtained by using "TD-DFT/B3LYP/6-311 + G(d,p)" level of theory to explain the vertical transitions. Calculated FT-IR and UV-Vis results are found to be in good agreement with experimental FT-IR and UV-Vis findings. Natural bond orbital (NBO) study was performed using B3LYP/6-311 + G(d,p) level to find the most stable molecular structure of the compounds. Frontier molecular orbital (FMO) analysis were performed at B3LYP/6-311 + G(d,p) level of theory, which indicates that the molecules might be bioactive. Moreover, the bioactivity of compounds (1) and (2) have been confirmed by the experimental activity in terms of zones of inhibition against bacteria and fungus. Chemical reactivity of compounds (1) and (2) was indicated by mapping molecular electrostatic potential (MEP) over the entire stabilized geometries of the compounds under study. The nonlinear optical properties were computed with B3LYP/6-311 + G(d,p) level of theory which are found greater than the value of urea due to conjugation effect. Two state model has been further employed to explain the nonlinear optical properties of compounds under investigation.

  4. Comprehensive analysis of TEM methods for LiFePO4/FePO4 phase mapping: spectroscopic techniques (EFTEM, STEM-EELS) and STEM diffraction techniques (ACOM-TEM).

    Science.gov (United States)

    Mu, X; Kobler, A; Wang, D; Chakravadhanula, V S K; Schlabach, S; Szabó, D V; Norby, P; Kübel, C

    2016-11-01

    Transmission electron microscopy (TEM) has been used intensively in investigating battery materials, e.g. to obtain phase maps of partially (dis)charged (lithium) iron phosphate (LFP/FP), which is one of the most promising cathode material for next generation lithium ion (Li-ion) batteries. Due to the weak interaction between Li atoms and fast electrons, mapping of the Li distribution is not straightforward. In this work, we revisited the issue of TEM measurements of Li distribution maps for LFP/FP. Different TEM techniques, including spectroscopic techniques (energy filtered (EF)TEM in the energy range from low-loss to core-loss) and a STEM diffraction technique (automated crystal orientation mapping (ACOM)), were applied to map the lithiation of the same location in the same sample. This enabled a direct comparison of the results. The maps obtained by all methods showed excellent agreement with each other. Because of the strong difference in the imaging mechanisms, it proves the reliability of both the spectroscopic and STEM diffraction phase mapping. A comprehensive comparison of all methods is given in terms of information content, dose level, acquisition time and signal quality. The latter three are crucial for the design of in-situ experiments with beam sensitive Li-ion battery materials. Furthermore, we demonstrated the power of STEM diffraction (ACOM-STEM) providing additional crystallographic information, which can be analyzed to gain a deeper understanding of the LFP/FP interface properties such as statistical information on phase boundary orientation and misorientation between domains. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Gamma spectroscopic studies of the neutron-deficient g-g nucleus 74Kr by means of a neutron multiplicity measurement technique

    International Nuclear Information System (INIS)

    Roth, J.

    1981-01-01

    The g-g nucleus 74 Kr was studied by means of the reaction 58 Ni ( 19 F, p2n#betta#) 74 Kr. In order to make gamma spectroscopic studies at neutron deficient nuclei like 74 Kr a neutron multiplicity measurement technique was developed. Beside #betta# single spectra, #betta# excitation functions, #betta#-#betta# coincidences, #betta# angular distributions, and lifetime measurements by means of this technique all measurements in coincidence with up to two neutrons were taken up. From these measurement data an extended term scheme with 17 newly found excited states could be extracted. To all levels spins and parities could be assigned. From the four energetically lowest levels of the yrast cascade the mean lifetimes could be determined. A double backbending in the sequence of the yrast cascade was interpreted as crossing of the g 9/2 bands. The irregularities in the lower part of the yrast band correspond to the shape consistence picture. The results were considered in connection with the systematics of the even krypton isotopes and compared with a two-quasiparticle-plas-rotor model calculation. (HSI)

  6. 1H Spectroscopic Imaging of Human Brain at 3T: Comparison of Fast 3D-MRSI Techniques

    Science.gov (United States)

    Zierhut, Matthew L.; Ozturk-Isik, Esin; Chen, Albert P.; Park, Ilwoo; Vigneron, Daniel B.; Nelson, Sarah J.

    2011-01-01

    Purpose To investigate the signal-to-noise-ratio (SNR) and data quality of time-reduced 1H 3D-MRSI techniques in the human brain at 3T. Materials and Methods Techniques that were investigated included ellipsoidal k-space sampling, parallel imaging, and EPSI. The SNR values for NAA, Cho, Cre, and lactate or lipid peaks were compared after correcting for effective spatial resolution and acquisition time in a phantom and in the brains of human volunteers. Other factors considered were linewidths, metabolite ratios, partial volume effects, and subcutaneous lipid contamination. Results In volunteers, the median normalized SNR for parallel imaging data decreased by 34–42%, but could be significantly improved using regularization. The normalized signal to noise loss in flyback EPSI data was 11–18%. The effective spatial resolutions of the traditional, ellipsoidal, SENSE, and EPSI data were 1.02, 2.43, 1.03, and 1.01cm3, respectively. As expected, lipid contamination was variable between subjects but was highest for the SENSE data. Patient data obtained using the flyback EPSI method were of excellent quality. Conclusions Data from all 1H 3D-MRSI techniques were qualitatively acceptable, based upon SNR, linewidths, and metabolite ratios. The larger FOV obtained with the EPSI methods showed negligible lipid aliasing with acceptable SNR values in less than 9.5 minutes without compromising the PSF. PMID:19711396

  7. A scheme to expand the delay-bandwidth product in the resonator-based delay lines by optical OFDM technique

    DEFF Research Database (Denmark)

    Zhu, Jiangbo; Tao, Li; Zhang, Ziran

    2013-01-01

    We propose a novel scheme to expand the inherent limit in the product of the optical delay and the transmission bandwidth in resonator-based delay lines, with the optical orthogonal frequency division multiplexing (OOFDM) technique. The optical group delay properties of a single ring resonator we...

  8. Fast in vivo bioluminescence tomography using a novel pure optical imaging technique

    Directory of Open Access Journals (Sweden)

    Shuang Zhang

    2017-05-01

    Full Text Available Bioluminescence tomography (BLT is a novel optical molecular imaging technique that advanced the conventional planar bioluminescence imaging (BLI into a quantifiable three-dimensional (3D approach in preclinical living animal studies in oncology. In order to solve the inverse problem and reconstruct tumor lesions inside animal body accurately, the prior structural information is commonly obtained from X-ray computed tomography (CT. This strategy requires a complicated hybrid imaging system, extensive post imaging analysis and involvement of ionizing radiation. Moreover, the overall robustness highly depends on the fusion accuracy between the optical and structural information. Here, we present a pure optical bioluminescence tomographic (POBT system and a novel BLT workflow based on multi-view projection acquisition and 3D surface reconstruction. This method can reconstruct the 3D surface of an imaging subject based on a sparse set of planar white-light and bioluminescent images, so that the prior structural information can be offered for 3D tumor lesion reconstruction without the involvement of CT. The performance of this novel technique was evaluated through the comparison with a conventional dual-modality tomographic (DMT system and a commercialized optical imaging system (IVIS Spectrum using three breast cancer xenografts. The results revealed that the new technique offered comparable in vivo tomographic accuracy with the DMT system (P>0.05 in much shorter data analysis time. It also offered significantly better accuracy comparing with the IVIS system (P<0.04 without sacrificing too much time.

  9. Generation and spectroscopic signatures of a fractional quantum Hall liquid of photons in an incoherently pumped optical cavity

    Science.gov (United States)

    Umucalılar, R. O.; Carusotto, I.

    2017-11-01

    We investigate theoretically a driven dissipative model of strongly interacting photons in a nonlinear optical cavity in the presence of a synthetic magnetic field. We show the possibility of using a frequency-dependent incoherent pump to create a strongly correlated ν =1 /2 bosonic Laughlin state of light: Due to the incompressibility of the Laughlin state, fluctuations in the total particle number and excitation of edge modes can be tamed by imposing a suitable external potential profile for photons. We further propose angular-momentum-selective spectroscopy of the emitted light as a tool to obtain unambiguous signatures of the microscopic physics of the quantum Hall liquid of light.

  10. Identification of cataract and post-cataract surgery optical images using artificial intelligence techniques.

    Science.gov (United States)

    Acharya, Rajendra Udyavara; Yu, Wenwei; Zhu, Kuanyi; Nayak, Jagadish; Lim, Teik-Cheng; Chan, Joey Yiptong

    2010-08-01

    Human eyes are most sophisticated organ, with perfect and interrelated subsystems such as retina, pupil, iris, cornea, lens and optic nerve. The eye disorder such as cataract is a major health problem in the old age. Cataract is formed by clouding of lens, which is painless and developed slowly over a long period. Cataract will slowly diminish the vision leading to the blindness. At an average age of 65, it is most common and one third of the people of this age in world have cataract in one or both the eyes. A system for detection of the cataract and to test for the efficacy of the post-cataract surgery using optical images is proposed using artificial intelligence techniques. Images processing and Fuzzy K-means clustering algorithm is applied on the raw optical images to detect the features specific to three classes to be classified. Then the backpropagation algorithm (BPA) was used for the classification. In this work, we have used 140 optical image belonging to the three classes. The ANN classifier showed an average rate of 93.3% in detecting normal, cataract and post cataract optical images. The system proposed exhibited 98% sensitivity and 100% specificity, which indicates that the results are clinically significant. This system can also be used to test the efficacy of the cataract operation by testing the post-cataract surgery optical images.

  11. Wavelength dependent pH optical sensor using the layer-by-layer technique

    OpenAIRE

    Raoufi, N.; Surre, F.; Sun, T.; Rajarajan, M.; Grattan, K. T. V.

    2012-01-01

    In this work, the design and characteristics of a wavelength-dependent pH optical sensor have been studied. To create the sensor itself, brilliant yellow (BY) as a pH indicator and poly (allylamine hydrochloride) [PAH] as a cross-linker have been deposited on the end of a bare silica core of an optical fibre by use of a ‘layer-by-layer’ technique. In the experiments carried out to characterize the sensor, it was observed that the value of pKa (the dissociation constant) of the thin film is de...

  12. Studying the structural and optical properties of Zn O:Cu prepared by APCVD technique

    International Nuclear Information System (INIS)

    Manssor, M.

    2012-01-01

    Undoped and Cu-doped Zn O ant (3-9 wt.%) thin films have been prepared by APCVD technique on glass substrates at 500 degree.The structural and optical properties of these films were studied. The results of the structural tests showed that these films are of a polycrystalline hexagonal structure with a preferred orientation in the (002) direction, the optical properties included transmittance, energy gap, ob sorption coefficient, reflectance, refractive index and extinction coefficient, the energy gap values were found to decrease from (3.25 to 3.15 eV) and the average transmittance was found about (90%) in the visible region. (author).

  13. State-of-the-Art Fluorescence Fluctuation-Based Spectroscopic Techniques for the Study of Protein Aggregation.

    Science.gov (United States)

    Kitamura, Akira; Kinjo, Masataka

    2018-03-23

    Neurodegenerative diseases, including amyotrophic lateral sclerosis (ALS), Alzheimer's disease, Parkinson's disease, and Huntington's disease, are devastating proteinopathies with misfolded protein aggregates accumulating in neuronal cells. Inclusion bodies of protein aggregates are frequently observed in the neuronal cells of patients. Investigation of the underlying causes of neurodegeneration requires the establishment and selection of appropriate methodologies for detailed investigation of the state and conformation of protein aggregates. In the current review, we present an overview of the principles and application of several methodologies used for the elucidation of protein aggregation, specifically ones based on determination of fluctuations of fluorescence. The discussed methods include fluorescence correlation spectroscopy (FCS), imaging FCS, image correlation spectroscopy (ICS), photobleaching ICS (pbICS), number and brightness (N&B) analysis, super-resolution optical fluctuation imaging (SOFI), and transient state (TRAST) monitoring spectroscopy. Some of these methodologies are classical protein aggregation analyses, while others are not yet widely used. Collectively, the methods presented here should help the future development of research not only into protein aggregation but also neurodegenerative diseases.

  14. Spectroscopic studies of the origin of radiation-induced degradation in phosphorus-doped optical fibers and preforms

    International Nuclear Information System (INIS)

    Origlio, G.; Messina, F.; Cannas, M.; Girard, S.; Boukenter, A.; Ouerdane, Y.

    2010-01-01

    In this paper, we study the radiation-induced point defects related to the phosphorus element that is commonly used to improve the optical properties of silica-based glasses but is responsible of a dramatic increase in their radiation sensitivity. To this aim, the influence of x-ray irradiation on prototype phosphorus-doped canonical fibers and their related preforms was investigated by in situ radiation induced attenuation (RIA), optical absorption, and electron spin resonance (ESR) spectroscopy. The RIA spectra in the (1.5-5 eV) range, can be explained by the presence of at least three absorption bands induced by radiation exposure. Additionally the X-dose dependence of such bands was studied. The main responsible defect for these absorption peaks was the phosphorus oxygen hole center (POHC) center, whose presence was also detected by ESR measurements both in irradiated fibers and preforms, together with the lineshape of the so called P2 defect. Correlations between the RIA bands and the ESR results allow us to assign the 2.3 and 3.0 eV bands to POHCs and to propose a scheme for the simultaneous creation of POHC and P2 defects after x-ray exposure.

  15. Atomic and Nuclear Analytical Methods XRF, Mössbauer, XPS, NAA and Ion-Beam Spectroscopic Techniques

    CERN Document Server

    Verma, H R

    2007-01-01

    This book is a blend of analytical methods based on the phenomenon of atomic and nuclear physics. It comprises comprehensive presentations about X-ray Fluorescence (XRF), Mössbauer Spectroscopy (MS), X-ray Photoelectron Spectroscopy (XPS), Neutron- Activation Analysis (NAA), Particle Induced X-ray Emission Analysis (PIXE), Rutherford Backscattering Analysis (RBS), Elastic Recoil Detection (ERD), Nuclear Reaction Analysis (NRA), Particle Induced Gamma-ray Emission Analysis (PIGE), and Accelerator Mass Spectrometry (AMS). These techniques are commonly applied in the fields of medicine, biology, environmental studies, archaeology or geology et al. and pursued in major international research laboratories.

  16. Spectroscopic On-Line Monitoring of Cu/W Contacts Erosion in HVCBs Using Optical-Fibre Based Sensor and Chromatic Methodology.

    Science.gov (United States)

    Wang, Zhixiang; Jones, Gordon R; Spencer, Joseph W; Wang, Xiaohua; Rong, Mingzhe

    2017-03-06

    Contact erosion is one of the most crucial factors affecting the electrical service lifetime of high-voltage circuit breakers (HVCBs). On-line monitoring the contacts' erosion degree is increasingly in demand for the sake of condition based maintenance to guarantee the functional operation of HVCBs. A spectroscopic monitoring system has been designed based upon a commercial 245 kV/40 kA S F 6 live tank circuit breaker with copper-tungsten (28 wt % and 72 wt %) arcing contacts at atmospheric S F 6 pressure. Three optical-fibre based sensors are used to capture the time-resolved spectra of arcs. A novel approach using chromatic methods to process the time-resolved spectral signal has been proposed. The processed chromatic parameters have been interpreted to show that the time variation of spectral emission from the contact material and quenching gas are closely correlated to the mass loss and surface degradation of the plug arcing contact. The feasibility of applying this method to online monitoring of contact erosion is indicated.

  17. Spectroscopic On-Line Monitoring of Cu/W Contacts Erosion in HVCBs Using Optical-Fibre Based Sensor and Chromatic Methodology

    Directory of Open Access Journals (Sweden)

    Zhixiang Wang

    2017-03-01

    Full Text Available Contact erosion is one of the most crucial factors affecting the electrical service lifetime of high-voltage circuit breakers (HVCBs. On-line monitoring the contacts’ erosion degree is increasingly in demand for the sake of condition based maintenance to guarantee the functional operation of HVCBs. A spectroscopic monitoring system has been designed based upon a commercial 245 kV/40 kA S F 6 live tank circuit breaker with copper–tungsten (28 wt % and 72 wt % arcing contacts at atmospheric S F 6 pressure. Three optical-fibre based sensors are used to capture the time-resolved spectra of arcs. A novel approach using chromatic methods to process the time-resolved spectral signal has been proposed. The processed chromatic parameters have been interpreted to show that the time variation of spectral emission from the contact material and quenching gas are closely correlated to the mass loss and surface degradation of the plug arcing contact. The feasibility of applying this method to online monitoring of contact erosion is indicated.

  18. Radio frequency phototube and optical clock: High resolution, high rate and highly stable single photon timing technique

    Energy Technology Data Exchange (ETDEWEB)

    Margaryan, Amur

    2011-10-01

    A new timing technique for single photons based on the radio frequency phototube and optical clock or femtosecond optical frequency comb generator is proposed. The technique has a 20 ps resolution for single photons, is capable of operating with MHz frequencies and achieving 10 fs instability level.

  19. The Optical Flow Technique on the Research of Solar Non-potentiality

    Science.gov (United States)

    Liu, Ji-hong; Zhang, Hong-qi

    2010-06-01

    Several optical flow techniques, which have being applied to the researches of solar magnetic non-potentiality recently, have been summarized here. And a few new non-potential parameters which can be derived from them have been discussed, too. The main components of the work are presented as follows: (1) The optical flow techniques refers to a series of new image analyzing techniques arisen recently on the researches of solar magnetic non-potentiality. They mainly include LCT (local correlation tracking), ILCT (inductive equation combining with LCT), MEF (minimum energy effect), DAVE (differential affine velocity estimator) and NAVE (nonlinear affine velocity estimator). Their calculating and applying conditions, merits and deficiencies, all have been discussed detailedly in this work. (2) Benefit from the optical flow techniques, the transverse velocity fields of the magnetic features on the solar surface may be determined by a time sequence of high-quality images currently produced by high-resolution observations either from the ground or in space. Consequently, several new non-potential parameters may be acquired, such as the magnetic helicity flux, the induced electric field in the photosphere, the non-potential magnetic stress (whose area integration is the Lorentz force), etc. Then we can determine the energy flux across the photosphere, and subsequently evaluate the energy budget. Former works on them by small or special samples have shown that they are probably related closely to the erupting events, such as flare, filament eruptions and coronal mass ejections.

  20. Techniques of surface optical breakdown prevention for low-depths femtosecond waveguides writing

    International Nuclear Information System (INIS)

    Bukharin, M A; Skryabin, N N; Ganin, D V; Khudyakov, D V; Vartapetov, S.K.

    2016-01-01

    We demonstrated technique of direct femtosecond waveguide writing at record low depth (2-15 μm) under surface of lithium niobate, that play a key role in design of electrooptical modulators with low operating voltage. To prevent optical breakdown of crystal surface we used high numerical aperture objectives for focusing of light and non-thermal regime of inscription in contrast to widespread femtosecond writing technique at depths of tens micrometers or higher. Surface optical breakdown threshold was measured for both x- and z- cut crystals. Inscribed waveguides were examined for intrinsic microstructure. It also reported sharp narrowing of operating pulses energy range with writing depth under the surface of crystal, that should be taken in account when near-surface waveguides design. Novelty of the results consists in reduction of inscription depth under the surface of crystals that broadens applications of direct femtosecond writing technique to full formation of near-surface waveguides and postproduction precise geometry correction of near-surfaces optical integrated circuits produced with proton-exchanged technique. (paper)

  1. Non-Linear Optical Studies On Sol-Gel Derived Lead Chloride Crystals Using Z-Scan Technique

    OpenAIRE

    Rejeena, I; Lillibai, B; Toms, Roseleena; Nampoori, VP N; Radhakrishnan, P

    2014-01-01

    In this paper we report the preparation, optical characterization and non linear optical behavior of pure lead chloride crystals. Lead chloride samples subjected to UV and IR irradiation and electric and magnetic fields have also been investigated Optical nonlinearity in these lead chloride samples were determined using single beam and high sensitive Z-scan technique. Non linear optical studies of these materials in single distilled water show reverse saturable absorption which makes th...

  2. Spectroscopic and imaging diagnostics of pulsed laser deposition laser plasmas

    International Nuclear Information System (INIS)

    Thareja, Raj K.

    2002-01-01

    An overview of laser spectroscopic techniques used in the diagnostics of laser ablated plumes used for thin film deposition is given. An emerging laser spectroscopic imaging technique for the laser ablation material processing is discussed. (author)

  3. Development of synchrotron x-ray micro-spectroscopic techniques and application to problems in low temperature geochemistry. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-01

    The focus of the technical development effort has been the development of apparatus and techniques for the utilization of X-ray Fluorescence (XRF), Extended X-ray Absorption Fine Structure (EXAFS) and X-ray Absorption Near Edge Structure (XANES) spectroscopies in a microprobe mode. The present XRM uses white synchrotron radiation (3 to 30 keV) from a bending magnet for trace element analyses using the x-ray fluorescence technique Two significant improvements to this device have been recently implemented. Focusing Mirror: An 8:1 ellipsoidal mirror was installed in the X26A beamline to focus the incident synchrotron radiation and thereby increase the flux on the sample by about a factor of 30. Incident Beam Monochromator: The monochromator has been successfully installed and commissioned in the X26A beamline upstream of the mirror to permit analyses with focused monochromatic radiation. The monochromator consists of a channel-cut silicon (111) crystal driven by a Klinger stepping motor translator. We have demonstrated the operating range of this instrument is 4 and 20 keV with 0.01 eV steps and produces a beam with a {approximately}10{sup {minus}4} energy bandwidth. The primary purpose of the monochromator is for x-ray absorption spectroscopy (XAS) measurements but it is also used for selective excitation in trace element microanalysis. To date, we have conducted XANES studies on Ti, Cr, Fe, Ce and U, spanning the entire accessible energy range and including both K and L edge spectra. Practical detection limits for microXANES are 10--100 ppM for 100 {mu}m spots.

  4. Precise oxygen and hydrogen isotope determination in nanoliter quantities of speleothem inclusion water by cavity ring-down spectroscopic techniques

    Science.gov (United States)

    Uemura, Ryu; Nakamoto, Masashi; Asami, Ryuji; Mishima, Satoru; Gibo, Masakazu; Masaka, Kosuke; Jin-Ping, Chen; Wu, Chung-Che; Chang, Yu-Wei; Shen, Chuan-Chou

    2016-01-01

    Speleothem inclusion-water isotope compositions are a promising new climatic proxy, but their applicability is limited by their low content in water and by analytical challenges. We have developed a precise and accurate isotopic technique that is based on cavity ring-down spectroscopy (CRDS). This method features a newly developed crushing apparatus, a refined sample extraction line, careful evaluation of the water/carbonate adsorption effect. After crushing chipped speleothem in a newly-developed crushing device, released inclusion water is purified and mixed with a limited amount of nitrogen gas in the extraction line for CRDS measurement. We have measured 50-260 nL of inclusion water from 77 to 286 mg of stalagmite deposits sampled from Gyokusen Cave, Okinawa Island, Japan. The small sample size requirement demonstrates that our analytical technique can offer high-resolution inclusion water-based paleoclimate reconstructions. The 1σ reproducibility for different stalagmites ranges from ±0.05 to 0.61‰ for δ18O and ±0.0 to 2.9‰ for δD. The δD vs. δ18O plot for inclusion water from modern stalagmites is consistent with the local meteoric water line. The 1000 ln α values based on calcite and fluid inclusion measurements from decades-old stalagmites are in agreement with the data from present-day farmed calcite experiment. Combination of coeval carbonate and fluid inclusion data suggests that past temperatures at 9-10 thousand years ago (ka) and 26 ka were 3.4 ± 0.7 °C and 8.2 ± 2.4 °C colder than at present, respectively.

  5. Role of Cu in engineering the optical properties of SnO2 nanostructures: Structural, morphological and spectroscopic studies

    Science.gov (United States)

    Kumar, Virender; Singh, Kulwinder; Jain, Megha; Manju; Kumar, Akshay; Sharma, Jeewan; Vij, Ankush; Thakur, Anup

    2018-06-01

    We have carried out a systematic study to investigate the effect of Cu doping on the optical properties of SnO2 nanostructures synthesized by chemical route. Synthesized nanostructures were characterized using X-ray diffraction (XRD), Field emission scanning electron microscopy (FE-SEM), High resolution transmission electron microscopy (HR-TEM), Energy dispersive X-ray spectroscopy, Raman spectroscopy, Fourier transform infrared (FTIR) spectroscopy, UV-visible and Photoluminescence (PL) spectroscopy. The Rietveld refinement analysis of XRD patterns of Cu-doped SnO2 samples confirmed the formation of single phase tetragonal rutile structure, however some localized distortion was observed for 5 mol% Cu-doped SnO2. Crystallite size was found to decrease with increase in dopant concentration. FE-SEM images indicated change in morphology of samples with doping. HR-TEM images revealed that synthesized nanostructures were nearly spherical and average crystallite size was in the range 12-21 nm. Structural defects, crystallinity and size effects on doping were investigated by Raman spectroscopy and results were complemented by FTIR spectroscopy. Optical band gap of samples was estimated from reflectance spectra. We have shown that band gap of SnO2 can be engineered from 3.62 to 3.82 eV by Cu doping. PL emission intensity increased as the doping concentration increased, which can be attributed to the development of defect states in the forbidden transition region of band gap of SnO2 with doping. We have also proposed a band model owing to defect states in SnO2 to explain the observed PL in Cu doped SnO2 nanostructures.

  6. Beam profile measurements on the advanced test accelerator using optical techniques

    International Nuclear Information System (INIS)

    Chong, Y.P.; Kalibjian, R.; Cornish, J.P.; Kallman, J.S.; Donnelly, D.

    1986-01-01

    Beam current density profiles of ATA have been measured both spatially and temporally using a number of diagnostics. An extremely important technique involves measuring optical emissions from either a target foil inserted into the beam path or gas atoms and molecules excited by beam electrons. This paper describes the detection of the optical emission. A 2-D gated television camera with a single or dual micro-channel-plate (MCP) detector for high gain provides excellent spatial and temporal resolution. Measurements are routinely made with resolutions of 1 mm and 5 ns respectively. The optical line of sight allows splitting part of the signal to a streak camera or photometer for even higher time resolution

  7. Application of Distributed Optical Fiber Sensing Technique in Monitoring the Ground Deformation

    Directory of Open Access Journals (Sweden)

    Jin Liu

    2017-01-01

    Full Text Available The monitoring of ground deformation is important for the prevention and control of geological disaster including land subsidence, ground fissure, surface collapse, and landslides. In this study, a distributed optical fiber sensing technique based on Brillouin Optical Time-Domain Analysis (BOTDA was used to monitor the ground deformation. The principle behind the BOTDA is first introduced, and then laboratory calibration test and physical model test were carried out. Finally, BOTDA-based monitoring of ground fissure was carried out in a test site. Experimental results show that the distributed optical fiber can measure the soil strain during ground deformation process, and the strain curve responded to the soil compression and tension region clearly. During field test in Wuxi City, China, the ground fissures deformation area was monitored accurately and the trend of deformation can also be achieved to forecast and warn against the ground fissure hazards.

  8. Fundamentals and techniques of nonimaging optics research at the University of Chicago

    Science.gov (United States)

    Winston, R.; Ogallagher, J.

    1986-11-01

    Nonimaging Optics differs from conventional approaches in its relaxation of unnecessary constraints on energy transport imposed by the traditional methods for optimizing image formation and its use of more broadly based analytical techniques such as phase space representations of energy flow, radiative transfer analysis, thermodynamic arguments, etc. Based on these means, techniques for designing optical elements which approach and in some cases attain the maximum concentration permitted by the Second Law of Thermodynamics were developed. The most widely known of these devices are the family of Compound Parabolic Concentrators (CPC's) and their variants and the so called Flow-Line concentrator derived from the geometric vector flux formalism developed under this program. Applications of these and other such ideal or near-ideal devices permits increases of typically a factor of four (though in some cases as much as an order of magnitude) in the concentration above that possible with conventional means. In the most recent phase, our efforts can be classed into two main areas; (a) ''classical'' geometrical nonimaging optics; and (b) logical extensions of nonimaging concepts to the physical optics domain.

  9. Flat-top pulse generation by the optical Fourier transform technique for ultrahigh speed signal processing

    DEFF Research Database (Denmark)

    Palushani, Evarist; Oxenløwe, Leif Katsuo; Galili, Michael

    2009-01-01

    This paper reports on the generation of 1.6-ps fullwidth at half-maximum flat-top pulses by the optical Fourier transform technique, and the utilization of these pulses in a 320-Gb/s demultiplexing experiment. It is demonstrated how a narrow pulse having a 15-nm wide third-order super-Gaussian sp......This paper reports on the generation of 1.6-ps fullwidth at half-maximum flat-top pulses by the optical Fourier transform technique, and the utilization of these pulses in a 320-Gb/s demultiplexing experiment. It is demonstrated how a narrow pulse having a 15-nm wide third-order super...

  10. A novel noninvasive all optical technique to monitor physiology of an exercising muscle

    Energy Technology Data Exchange (ETDEWEB)

    Saxena, Vishal [Department of Radiology, University of Southern California, 4650 Sunset Blvd., Los Angeles, CA 90027 (United States); Marcu, Laura [Department of Bioengineering, University of California at Davis, Davis, CA 95616 (United States); Karunasiri, Gamani [Department of Physics, Naval Postgraduate School, Monterey, California 93943 (United States)], E-mail: Vsaxena@usc.edu

    2008-11-07

    An all optical technique based on near-infrared spectroscopy and mid-infrared imaging (MIRI) is applied as a noninvasive, in vivo tool to monitor the vascular status of skeletal muscle and the physiological changes that occur during exercise. A near-infrared spectroscopy (NIRS) technique, namely, steady state diffuse optical spectroscopy (SSDOS) along with MIRI is applied for monitoring the changes in the values of tissue oxygenation and thermometry of an exercising muscle. The NIRS measurements are performed at five discrete wavelengths in a spectral window of 650-850 nm and MIRI is performed in a spectral window of 8-12 {mu}m. The understanding of tissue oxygenation status and the behavior of the physiological parameters derived from thermometry may provide a useful insight into muscle physiology, therapeutic response and treatment.

  11. Multimodal imaging of vascular network and blood microcirculation by optical diagnostic techniques

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Meglinski, I V

    2011-01-01

    We present a multimodal optical diagnostic approach for simultaneous non-invasive in vivo imaging of blood and lymphatic microvessels, utilising a combined use of fluorescence intravital microscopy and a method of dynamic light scattering. This approach makes it possible to renounce the use of fluorescent markers for visualisation of blood vessels and, therefore, significantly (tenfold) reduce the toxicity of the technique and minimise side effects caused by the use of contrast fluorescent markers. We demonstrate that along with the ability to obtain images of lymph and blood microvessels with a high spatial resolution, current multimodal approach allows one to observe in real time permeability of blood vessels. This technique appears to be promising in physiology studies of blood vessels, and especially in the study of peripheral cardiovascular system in vivo. (optical technologies in biophysics and medicine)

  12. A novel noninvasive all optical technique to monitor physiology of an exercising muscle

    International Nuclear Information System (INIS)

    Saxena, Vishal; Marcu, Laura; Karunasiri, Gamani

    2008-01-01

    An all optical technique based on near-infrared spectroscopy and mid-infrared imaging (MIRI) is applied as a noninvasive, in vivo tool to monitor the vascular status of skeletal muscle and the physiological changes that occur during exercise. A near-infrared spectroscopy (NIRS) technique, namely, steady state diffuse optical spectroscopy (SSDOS) along with MIRI is applied for monitoring the changes in the values of tissue oxygenation and thermometry of an exercising muscle. The NIRS measurements are performed at five discrete wavelengths in a spectral window of 650-850 nm and MIRI is performed in a spectral window of 8-12 μm. The understanding of tissue oxygenation status and the behavior of the physiological parameters derived from thermometry may provide a useful insight into muscle physiology, therapeutic response and treatment.

  13. Application of Spectroscopic Techniques for the Determination of Trace Element Concentrations in some Sudanese vegetables and fruits

    International Nuclear Information System (INIS)

    Ahmed, A. N.; Ali, A. H.; Eltayeb, M. A. H.; Othman, M. M.; Taha, K. K.

    2004-01-01

    The objectives of this study were to determine the levels of the mineral nutrients, especially of trace elements, in some food items commonly consumed in Sudan and to compare the results of this work with local and international data. Food samples of fruits and vegetables were collected from different localities in Sudan. The samples were then prepared and their Br, Ca, Co, Cu, Fe, Mg, Mn, P, Pb, Na, Rb, Sr, and Zn content were determined using Atomic absorption spectroscopy (AAS), X-ray fluorescence spectroscopy (XRF), flame photometry and colorimetry. Verified standards TDD-1D and Hay-9 (supplied by the IAEA) were measured using the techniques mentioned above for accuracy. The Sudanese food items analyzed were found to contain considerable ranges of nutrients as follows: - Concentration levels for some of these elements Ca, Cu and Fe show higher values in fruits (4709, 21, and 633 ppm, respectively), and lower in vegetables (4094, 13, and 255 ppm , respectively). Pb and Mn were higher in vegetables (2 and 32 ppm, respectively) and lower in fruits (1 and 18 ppm) respectively). Na and Zn were higher in vegetables (3149 and 26 ppm, respectively) and lower in fruits (269 and 13 ppm, respectively). The values obtained agree, in general, with data available from other countries. Variations were observed among certain varieties of food. (Authors)

  14. Evaluation of the effect of polymorphism on G-quadruplex-ligand interaction by means of spectroscopic and chromatographic techniques

    Science.gov (United States)

    Benito, S.; Ferrer, A.; Benabou, S.; Aviñó, A.; Eritja, R.; Gargallo, R.

    2018-05-01

    Guanine-rich sequences may fold into highly ordered structures known as G-quadruplexes. Apart from the monomeric G-quadruplex, these sequences may form multimeric structures that are not usually considered when studying interaction with ligands. This work studies the interaction of a ligand, crystal violet, with three guanine-rich DNA sequences with the capacity to form multimeric structures. These sequences correspond to short stretches found near the promoter regions of c-kit and SMARCA4 genes. Instrumental techniques (circular dichroism, molecular fluorescence, size-exclusion chromatography and electrospray ionization mass spectrometry) and multivariate data analysis were used for this purpose. The polymorphism of G-quadruplexes was characterized prior to the interaction studies. The ligand was shown to interact preferentially with the monomeric G-quadruplex; the binding stoichiometry was 1:1 and the binding constant was in the order of 105 M-1 for all three sequences. The results highlight the importance of DNA treatment prior to interaction studies.

  15. Study on the interaction of tussilagone with human serum albumin (HSA) by spectroscopic and molecular docking techniques

    Science.gov (United States)

    Xu, Liang; Hu, Yan-Xi; Li, Yan-Cheng; Zhang, Li; Ai, Hai-Xin; Liu, Hong-Sheng; Liu, Yu-Feng; Sang, Yu-Li

    2017-12-01

    Tussilagone is a sesquiterpenoid which exhibits a variety of pharmacological activities. The interaction of tussilagone with human serum albumin (HSA) was investigated using fluorescence spectroscopy, UV-vis absorption, fluorescence probe experiments, synchronous fluorescence, circular dichroism (CD) spectra, three-dimensional spectra and molecular docking techniques under simulative physiological conditions. The results clarified that the fluorescence quenching of HSA by tussilagone was a static quenching process as a result of HSA-tussilagone (1:1) complex. Tussilagone spontaneously bound to HSA in site I (subdomain IIA), which was primarily driven by hydrophobic forces and hydrogen bonds (ΔH° = -13.89 kJ mol-1, ΔS° = 16.39 J mol-1 K-1). The binding constant was calculated to be 2.182 × 103 L mol-1 and the binding distance was estimated to be 2.07 nm at 291 K, showing the occurrence of fluorescence energy transfer. The results of CD, synchronous and three-dimensional fluorescence spectra all revealed that tussilagone induced the conformational changes of HSA. Meanwhile, the study of molecular docking also indicated that tussilagone could bind to the site I of HSA mainly by hydrophobic and hydrogen bond interactions.

  16. Using terahertz time-domain spectroscopical technique to monitor cocrystal formation between piracetam and 2,5-dihydroxybenzoic acid

    Science.gov (United States)

    Du, Yong; Xia, Yi; Zhang, Huili; Hong, Zhi

    2013-07-01

    Far-infrared vibrational absorption of cocrystal formation between 2,5-dihydroxybenzoic acid (2,5-DHBA) and piracetam compounds under solvent evaporation and grinding methods have been investigated using terahertz time-domain spectroscopy (THz-TDS) at room temperature. The experimental results show large difference among absorption spectra of the formed cocrystals and the involved individual parent molecules in 0.20-1.50 THz region, which probably originated from the intra-molecular and inter-molecular hydrogen bonds due to the presence of two hydroxyl groups in 2,5-DHBA and amide moieties in piracetam compound. The THz absorption spectra of two formed cocrystals with different methods are almost identical. With grinding method, the reaction process can be monitored directly from both time-domain and frequency-domain spectra using THz-TDS technique. The results indicate that THz-TDS technology can absolutely offer us a high potential method to identify and characterize the formed cocrystals, and also provide the rich information about their reaction dynamic process involving two or more molecular crystals in situ to better know the corresponding reaction mechanism in pharmaceutical fields.

  17. Combined spectroscopic and molecular docking techniques to study interaction of Zn (II) DiAmsar with serum albumins

    Energy Technology Data Exchange (ETDEWEB)

    Bardajee, Ghasem Rezanejade, E-mail: rezanejad@pnu.ac.ir; Hooshyar, Zari; Shafagh, Pegah; Ghiasvand, Samira; Kakavand, Nahaleh

    2014-12-15

    Zinc (II) diamine-sarcophagine (Zn (II) DiAmsar) as a water soluble hexadentate ligand was synthesized and characterized by nuclear magnetic resonance (NMR), Fourier transform infrared (FT-IR) and UV–visible (UV–vis) spectroscopy. The bindings of Zn (II) DiAmsar with human serum albumin (HSA) and bovine serum albumin (BSA) were investigated under the simulative physiological conditions. To study this binding, the fluorescence spectra in combination with FT-IR, UV–vis, cyclic voltammetry (CV), and molecular docking techniques were used in the present work. The results indicate that Zn (II) DiAmsar quenched effectively the intrinsic fluorescence of HSA and BSA via a static quenching process. The fluorescence quenching data was also used to determine binding sites and binding constants at different temperatures. The calculated thermodynamic parameters (∆G°, ∆H°, and ∆S°) suggest that the binding process occurs spontaneously by involving hydrogen bond and van der Waals interactions. The distance between HSA (or BSA) as a donor and Zn (II) DiAmsar as an acceptor was obtained according to fluorescence resonance energy transfer (FRET). In addition, the docking results revealed the possible binding sites and assess the microenvironment around the bounded Zn (II) DiAmsar.

  18. X-ray spectroscopic technique for energetic electron transport studies in short-pulse laser/plasma interactions

    Energy Technology Data Exchange (ETDEWEB)

    Tutt, T.E.

    1994-12-01

    When a solid target is irradiated by a laser beam, the material is locally heated to a high temperature and a plasma forms. The interaction of the laser with plasma can produce energetic electrons. By observing the behavior of these {open_quotes}hot{close_quotes} electrons, we hope to obtain a better understanding of Laser/Plasma Interactions. In this work we employ a layered-fluorescer technique to study the transport, and therefore the energetics, of the electrons. The plasma forms on a thin foil of metallic Pd which is bonded to thin layer of metallic Sn. Electrons formed from the plasma penetrate first the Pd and then the Sn. In both layers the energetic electrons promote inner (K) shell ionization of the metallic atoms which leads to the emission of characteristic K{sub {alpha}} x-rays of the fluorescers. By recording the x-ray spectrum emitted by the two foils, we can estimate the energy-dependent range of the electrons and their numbers.

  19. A study on the interaction of horse heart cytochrome c with some conventional and ionic liquid surfactants probed by ultraviolet-visible and fluorescence spectroscopic techniques.

    Science.gov (United States)

    Mondal, Satyajit; Das, Bijan

    2018-06-05

    The interactions of a protein cytochrome c with some selected conventional and ionic liquid surfactants have been investigated at pH7.4 using ultraviolet-visible and fluorescence spectroscopic techniques. We used four conventional surfactants - cetyltrimethylammonium bromide (CTAB), dodecyltrimethylammonium bromide (DTAB), sodium N-dodecanoylsarcosinate (SDDS), and N-decanoyl-N-methylglucamine (Mega 10), and a surface active ionic liquid 1-hexadecyl-3-methylimidazolium chloride (C 16 MeImCl). All the investigated surfactants were found to induce an unfolding of the protein cytochrome c. In presence of CTAB, SDDS and C 16 MeImCl, the heme iron atom was found to loose methionine from its axial position. Differential binding of the surfactant monomers and their micelles to the protein molecules was inferred. The ionic surfactants were found to be more effective than the nonionic one in unfolding the investigated protein. However, the extent of binding of CTAB/C 16 MeImCl to cytochrome c reaches a plateau past the critical micellization concentration (cmc) of the surfactant. For each of the cytochrome c-DTAB, cytochrome c-SDDS and cytochrome c-Mega 10 system, although there exists an inflection in the surfactant-binding, saturation point could not be detected. It has been demonstrated from the ultraviolet-visible spectral studies that the oxidation state of iron in cytochrome c does not change when the protein binds with the investigated surfactants. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Use of spectroscopic and imaging techniques to evaluate pretreated sugarcane bagasse as a substrate for cellulase production under solid-state fermentation.

    Science.gov (United States)

    Rodríguez-Zúñiga, Ursula Fabiola; Bertucci Neto, Victor; Couri, Sonia; Crestana, Silvio; Farinas, Cristiane Sanchez

    2014-03-01

    The enzymatic cocktail of cellulases is one of the most costly inputs affecting the economic viability of the biochemical route for biomass conversion into biofuels and other chemicals. Here, the influence of liquid hot water, dilute acid, alkali, and combined acid/alkali pretreatments on sugarcane bagasse (SCB) used for cellulase production was investigated by means of spectroscopic and imaging techniques. Chemical composition and structural characteristics, such as crystallinity (determined by X-ray diffraction), functional groups (Fourier transform infrared spectroscopy), and microstructure (scanning electron microscopy), were used to correlate SCB pretreatments with enzymatic biosynthesis by a strain of the filamentous fungus Aspergillus niger under solid-state fermentation. The combined acid/alkali pretreatment resulted in a SCB with higher cellulose content (86.7%). However, the high crystallinity (74%) of the resulting biomass was detrimental to microbial uptake and enzyme production. SCB pretreated with liquid hot water yielded the highest filter paper cellulase (FPase), carboxymethyl cellulase (CMCase), and xylanase activities (0.4, 14.9, and 26.1 U g(-1), respectively). The results showed that a suitable pretreatment for SCB to be used as a substrate for cellulase production should avoid severe conditions in order to preserve amorphous cellulose and to enhance the physical properties that assist microbial access.

  1. A study on the interaction of horse heart cytochrome c with some conventional and ionic liquid surfactants probed by ultraviolet-visible and fluorescence spectroscopic techniques

    Science.gov (United States)

    Mondal, Satyajit; Das, Bijan

    2018-06-01

    The interactions of a protein cytochrome c with some selected conventional and ionic liquid surfactants have been investigated at pH 7.4 using ultraviolet-visible and fluorescence spectroscopic techniques. We used four conventional surfactants - cetyltrimethylammonium bromide (CTAB), dodecyltrimethylammonium bromide (DTAB), sodium N-dodecanoylsarcosinate (SDDS), and N-decanoyl-N-methylglucamine (Mega 10), and a surface active ionic liquid 1-hexadecyl-3-methylimidazolium chloride (C16MeImCl). All the investigated surfactants were found to induce an unfolding of the protein cytochrome c. In presence of CTAB, SDDS and C16MeImCl, the heme iron atom was found to loose methionine from its axial position. Differential binding of the surfactant monomers and their micelles to the protein molecules was inferred. The ionic surfactants were found to be more effective than the nonionic one in unfolding the investigated protein. However, the extent of binding of CTAB/C16MeImCl to cytochrome c reaches a plateau past the critical micellization concentration (cmc) of the surfactant. For each of the cytochrome c-DTAB, cytochrome c-SDDS and cytochrome c-Mega 10 system, although there exists an inflection in the surfactant-binding, saturation point could not be detected. It has been demonstrated from the ultraviolet-visible spectral studies that the oxidation state of iron in cytochrome c does not change when the protein binds with the investigated surfactants.

  2. High capacity fiber optic sensor networks using hybrid multiplexing techniques and their applications

    Science.gov (United States)

    Sun, Qizhen; Li, Xiaolei; Zhang, Manliang; Liu, Qi; Liu, Hai; Liu, Deming

    2013-12-01

    Fiber optic sensor network is the development trend of fiber senor technologies and industries. In this paper, I will discuss recent research progress on high capacity fiber sensor networks with hybrid multiplexing techniques and their applications in the fields of security monitoring, environment monitoring, Smart eHome, etc. Firstly, I will present the architecture of hybrid multiplexing sensor passive optical network (HSPON), and the key technologies for integrated access and intelligent management of massive fiber sensor units. Two typical hybrid WDM/TDM fiber sensor networks for perimeter intrusion monitor and cultural relics security are introduced. Secondly, we propose the concept of "Microstructure-Optical X Domin Refecltor (M-OXDR)" for fiber sensor network expansion. By fabricating smart micro-structures with the ability of multidimensional encoded and low insertion loss along the fiber, the fiber sensor network of simple structure and huge capacity more than one thousand could be achieved. Assisted by the WDM/TDM and WDM/FDM decoding methods respectively, we built the verification systems for long-haul and real-time temperature sensing. Finally, I will show the high capacity and flexible fiber sensor network with IPv6 protocol based hybrid fiber/wireless access. By developing the fiber optic sensor with embedded IPv6 protocol conversion module and IPv6 router, huge amounts of fiber optic sensor nodes can be uniquely addressed. Meanwhile, various sensing information could be integrated and accessed to the Next Generation Internet.

  3. Generalized 1D photopyroelectric technique for optical and thermal characterization of liquids

    International Nuclear Information System (INIS)

    Balderas-López, J A

    2012-01-01

    The analytical solution for the one-dimensional heat diffusion problem for a three-layer system, in the Beer–Lambert model for light absorption, is used for the implementation of a photopyroelectric (PPE) methodology for thermal and optical characterization of pigments in liquid solution, even for those ones potentially harmful to the pyroelectric sensor, taking the liquid sample's thickness as the only variable. Exponential decay of the PPE amplitude followed by a constant PPE phase for solutions at low pigment concentration, and exponential decay of the PPE amplitude but a linear decrease of the PPE phase for the concentrated ones are theoretically shown, allowing measurements of the optical absorption coefficient (at the wavelength used for the analysis) and the thermal diffusivity for the liquid sample, respectively. This PPE methodology was tested by measuring the thermal diffusivity of a concentrated solution of methylene blue in distilled water and the optical absorption coefficient, at two wavelengths (658 and 785 nm), of water solutions of copper sulfate at various concentrations. These optical parameters were used for measuring the molar absorption coefficient of this last pigment in water solution at these two wavelengths. This last optical property was also measured using a commercial spectrometer, finding very good agreement with the corresponding ones using this PPE technique. (paper)

  4. Fiber Strain Measurement for Wide Region Quasidistributed Sensing by Optical Correlation Sensor with Region Separation Techniques

    Directory of Open Access Journals (Sweden)

    Xunjian Xu

    2010-01-01

    Full Text Available The useful application of optical pulse correlation sensor for wide region quasidistributed fiber strain measurement is investigated. Using region separation techniques of wavelength multiplexing with FBGs and time multiplexing with intensity partial reflectors, the sensor measures the correlations between reference pulses and monitoring pulses from several cascadable selected sensing regions. This novel sensing system can select the regions and obtain the distributed strain information in any desired sensing region.

  5. Effective Design for Optical CDMA Based on Radio over Fiber (RoF Technique

    Directory of Open Access Journals (Sweden)

    Rashidi C. B. M.

    2017-01-01

    Full Text Available In this paper, the performance of OCDMA coding systems utilizing the radio over fiber (RoF technique is presented. It has been done by means of conventional OptiSystem simulation tools, where the propagation of radio signals up to 50 km using standard single mode fiber (SMF was investigated. The analysis was made based on the performance of eye diagram, bit rate, bit error rate and optical received power.

  6. Synthesis of MgO Nanoparticles by Solvent Mixed Spray Pyrolysis Technique for Optical Investigation

    OpenAIRE

    Nemade, K. R.; Waghuley, S. A.

    2014-01-01

    Solvent mixed spray pyrolysis technique has attracted a global interest in the synthesis of nanomaterials since reactions can be run in liquid state without further heating. Magnesium oxide (MgO) is a category of the practical semiconductor metal oxides, which is extensively used as catalyst and optical material. In the present study, MgO nanoparticles were successfully synthesized using a solvent mixed spray pyrolysis. The X-ray diffraction pattern confirmed the formation of MgO phase with a...

  7. All-optical optoacoustic microscopy based on probe beam deflection technique

    OpenAIRE

    Maswadi, Saher M.; Ibey, Bennett L.; Roth, Caleb C.; Tsyboulski, Dmitri A.; Beier, Hope T.; Glickman, Randolph D.; Oraevsky, Alexander A.

    2016-01-01

    Optoacoustic (OA) microscopy using an all-optical system based on the probe beam deflection technique (PBDT) for detection of laser-induced acoustic signals was investigated as an alternative to conventional piezoelectric transducers. PBDT provides a number of advantages for OA microscopy including (i) efficient coupling of laser excitation energy to the samples being imaged through the probing laser beam, (ii) undistorted coupling of acoustic waves to the detector without the need for separa...

  8. New autocorrelation technique for the IR FEL optical pulse width measurements

    Energy Technology Data Exchange (ETDEWEB)

    Amirmadhi, F.; Brau, K.A.; Becker, C. [Vanderbilt Univ., Nashville, TN (United States)] [and others

    1995-12-31

    We have developed a new technique for the autocorrelation measurement of optical pulse width at the Vanderbilt University FEL center. This method is based on nonlinear absorption and transmission characteristics of semiconductors such as Ge, Te and InAs suitable for the wavelength range from 2 to over 6 microns. This approach, aside being simple and low cost, removes the phase matching condition that is generally required for the standard frequency doubling technique and covers a greater wavelength range per nonlinear material. In this paper we will describe the apparatus, explain the principal mechanism involved and compare data which have been acquired with both frequency doubling and two-photon absorption.

  9. Comparison between optical techniques and confocal microscopy for defect detection on thin wires

    International Nuclear Information System (INIS)

    Siegmann, Philip; Sanchez-Brea, Luis Miguel; Martinez-Anton, Juan Carlos; Bernabeu, Eusebio

    2004-01-01

    Conventional microscopy techniques, such as atomic force microscopy (AFM), scanning electron microscopy (SEM), and confocal microscopy (CM) are not suitable for on-line surface inspection of fine metallic wires. In the recent years, some optical techniques have been developed to be used for those tasks. However, they need a rigorous validation. In this work, we have used confocal microscopy to obtain the topography z(x,y) of wires with longitudinal defects, such as dielines. The topography has been used to predict the light scattered by the wire. These simulations have been compared with experimental results, showing a good agreement

  10. Muscle tissue saturation in humans studied with two non-invasive optical techniques: a comparative study

    Science.gov (United States)

    Shaharin, Alfi; Krite Svanberg, Emilie; Ellerström, Ida; Subash, Arman Ahamed; Khoptyar, Dmitry; Andersson-Engels, Stefan; Åkeson, Jonas

    2013-11-01

    Muscle tissue saturation (StO2) has been measured with two non-invasive optical techniques and the results were compared. One of the techniques is widely used in the hospitals - the CW-NIRS technique. The other is the photon timeof- flight spectrometer (pTOFS) developed in the Group of Biophotonics, Lund University, Sweden. The wavelengths used in both the techniques are 730 nm and 810 nm. A campaign was arranged to perform measurements on 21 (17 were taken for comparison) healthy adult volunteers (8 women and 13 men). Oxygen saturations were measured at the right lower arm of each volunteer. To observe the effects of different provocations on the oxygen saturation a blood pressure cuff was attached in the upper right arm. For CW-NIRS, the tissue saturation values were in the range from 70-90%, while for pTOFS the values were in the range from 55-60%.

  11. An assessment of contemporary atomic spectroscopic techniques for the determination of lead in blood and urine matrices

    Science.gov (United States)

    Parsons, Patrick J.; Geraghty, Ciaran; Verostek, Mary Frances

    2001-09-01

    The preparation and validation of a number of clinical reference materials for the determination of lead in blood and urine is described. Four candidate blood lead reference materials (Lots, 047-050), and four candidate urine lead reference materials (Lots, 034, 035, 037 and 038), containing physiologically-bound lead at clinically relevant concentrations, were circulated to up to 21 selected laboratories specializing in this analysis. Results from two interlaboratory studies were used to establish certified values and uncertainty estimates for these reference materials. These data also provided an assessment of current laboratory techniques for the measurement of lead in blood and urine. For the blood lead measurements, four laboratories used electrothermal atomization AAS, three used anodic stripping voltammetry and one used both ETAAS and ICP-MS. For the urine lead measurements, 11 laboratories used ETAAS (most with Zeeman background correction) and 10 used ICP-MS. Certified blood lead concentrations, ±S.D., ranged from 5.9±0.4 μg/dl (0.28±0.02 μmol/l) to 76.0±2.2 μg/dl (3.67±0.11 μmol/l) and urine lead concentrations ranged from 98±5 μg/l (0.47±0.02 μmol/l) to 641±36 μg/l (3.09±0.17 μmol/l). The highest concentration blood lead material was subjected to multiple analyses using ETAAS over an extended time period. The data indicate that more stringent internal quality control practices are necessary to improve long-term precision. While the certification of blood lead materials was accomplished in a manner consistent with established practices, the urine lead materials proved more troublesome, particularly at concentrations above 600 μg/l (2.90 μmol/l).

  12. In-depth investigation on physicochemical and thermal properties of magnesium (II gluconate using spectroscopic and thermoanalytical techniques

    Directory of Open Access Journals (Sweden)

    Mahendra Kumar Trivedi

    2017-10-01

    Full Text Available Magnesium gluconate is a classical organometallic pharmaceutical compound used for the prevention and treatment of hypomagnesemia as a source of magnesium ion. The present research described the in-depth study on solid state properties viz. physicochemical and thermal properties of magnesium gluconate using sophisticated analytical techniques like PXRD, PSA, FT-IR, UV–Vis spectroscopy, TGA/DTG, and DSC. Magnesium gluconate was found to be crystalline in nature along with the crystallite size ranging from 14.10 to 47.35 nm. The particle size distribution was at d(0.1=6.552 µm, d(0.5=38.299 µm, d(0.9=173.712 µm and D(4,3=67.122 µm along with the specific surface area of 0.372 m2/g. The wavelength for the maximum absorbance was at 198.0 nm. Magnesium gluconate exhibited 88.51% weight loss with three stages of thermal degradation process up to 895.18 °C from room temperature. The TGA/DTG thermograms of the analyte indicated that magnesium gluconate was thermally stable up to around 165 °C. Consequently, the melting temperature of magnesium gluconate was found to be 169.90 °C along with the enthalpy of fusion of 308.7 J/g. Thus, the authors conclude that the achieved results from this study are very useful in pharmaceutical and nutraceutical industries for the identification, characterization and qualitative analysis of magnesium gluconate for preformulation studies and also for developing magnesium gluconate based novel formulation.

  13. Optimization of sunflower oil methanolysis for the production of biodiesel and its characterization with spectroscopic techniques (abstract)

    International Nuclear Information System (INIS)

    Tariq, M.; Ali, S.; Khalid, N.; Naureen, R.; Rafique, U.

    2011-01-01

    Esters from vegetable oils have attracted a great deal of interest as substitute for petrodiesel to reduce dependence on imported petroleum and provide an alternate and sustainable source for fuel with more benign environmental properties. In the present study biodiesel was prepared from sunflower seed oil by transesterification by alkali-catalyzed methanolysis. The fuel properties like kinematic viscosity, density, specific gravity, flash point, pour point, cloud point, acid number and colour comparison of sunflower oil biodiesel (SOB) were determined and discussed in the light of ASTM D6751 standards for biodiesel. The SOB was chemically characterized with analytical techniques like FT-IR, NMR (/sup 1/H and /sup 13/C). The chemical composition of SOB was determined by GC-MS. Various fatty acid methyl esters (FAMEs) were identified by retention time data and verified by mass fragmentation patterns. The identified FAMEs were methyl dodecanoate (C/sub 12:0/), methyl tetradecanoate(C/sub 14:0/), methyl hexadecanoate (C/sub 16:0/), methyl 8,11-octadecadienoate (C/sub 18:2/), methyl 9-octadecenoate (C/sub 18:1/), methyl octadecanoate (C/sub 18:0/), methyl 11-eicosenoate (C/sub 20:1/), methyl eicosanoate (C/sub 20:0/), methyl 13-docosenoate(C/sub 22:1/), methyl docosenoate(C/sub 22:0/) and methyl tetracosanoate (C/sub 24:0/). The percentage conversion of triglycerides to corresponding methyl esters determined by /sup 1/H-NMR was 87.33 % which was quite in good agreement with the practically observed yield of 85.1 %. (author)

  14. #%In-depth investigation on physicochemical and thermal properties of magnesium (II) gluconate using spectroscopic and thermoanalytical techniques

    Institute of Scientific and Technical Information of China (English)

    #

    2017-01-01

    Magnesium gluconate is a classical organometallic pharmaceutical compound used for the prevention and treatment of hypomagnesemia as a source of magnesium ion. The present research described the in-depth study on solid state properties viz. physicochemical and thermal properties of magnesium gluconate using sophisticated analytical techniques like Powder X-ray diffraction (PXRD), particle size analysis ( PSA), Fourier transform infrared (FT-IR) spectrometry, ultraviolet–visible (UV–Vis) spectroscopy, thermogravimetric analysis (TGA)/differential thermogravimetric analysis (DTG), and differential scanning calorimetry (DSC). Magnesium gluconate was found to be crystalline in nature along with the crystallite size ranging from 14.10 to 47.35 nm. The particle size distribution was at d(0.1)=6.552 μm, d(0.5)=38.299 μm, d(0.9)=173.712 μm and D(4,3)=67.122 μm along with the specific surface area of 0.372 m2/g. The wavelength for the maximum absorbance was at 198.0 nm. Magnesium gluconate exhibited 88.51% weight loss with three stages of thermal degradation process up to 895.18 ℃ from room temperature. The TGA/DTG thermograms of the analyte indicated that magnesium gluconate was thermally stable up to around 165 ℃. Consequently, the melting temperature of magnesium gluconate was found to be 169.90 ℃ along with the enthalpy of fusion of 308.7 J/g. Thus, the authors conclude that the achieved results from this study are very useful in pharmaceutical and nutraceutical industries for the identification, characterization and qualitative analysis of magnesium gluconate for preformulation studies and also for developing magnesium gluconate based novel formulation.

  15. Vibrational spectroscopic, structural and nonlinear optical activity studies on 2-amino-3-chloro-5-trifluoromethyl pyridine: A DFT approach

    Science.gov (United States)

    Asath, R. Mohamed; Premkumar, S.; Rekha, T. N.; Jawahar, A.; Mathavan, T.; Benial, A. Milton Franklin

    2016-05-01

    The conformational analysis was carried out for 2-amino-3-chloro-5-trifluoromethylpyridine using potential energy surface (PES) scan and the most stable optimized conformer was predicted. The theoretical vibrational frequencies were calculated for the optimized geometry using DFT/B3LYP cc-pVQZ basis set by Gaussian 09 Program. The vibrational frequencies were assigned on the basis of potential energy distribution calculation using VEDA 4.0 program package. The Mulliken atomic charge values were calculated. In the Frontier molecular orbitals analysis, the molecular reactivity, kinetic stability, intermolecular charge transfer studies and the calculation of ionization energy, electron affinity, global hardness, chemical potential, electrophilicity index and softness of the molecule were carried out. The nonlinear optical (NLO) activity was studied and the first order hyperpolarizability value was computed, which was 3.48 times greater than the urea. The natural bond orbital analysis was also performed to confirm the NLO activity of the molecule. Hence, the ACTP molecule is a promising candidate for NLO materials.

  16. Laser-induced carbon plasma emission spectroscopic measurements on solid targets and in gas-phase optical breakdown

    International Nuclear Information System (INIS)

    Nemes, Laszlo; Keszler, Anna M.; Hornkohl, James O.; Parigger, Christian

    2005-01-01

    We report measurements of time- and spatially averaged spontaneous-emission spectra following laser-induced breakdown on a solid graphite/ambient gas interface and on solid graphite in vacuum, and also emission spectra from gas-phase optical breakdown in allene C3H4 and helium, and in CO2 and helium mixtures. These emission spectra were dominated by CII (singly ionized carbon), CIII (doubly ionized carbon), hydrogen Balmer beta (H b eta), and Swan C2 band features. Using the local thermodynamic equilibrium and thin plasma assumptions, we derived electron number density and electron temperature estimates. The former was in the 1016 cm -3 range, while the latter was found to be near 20000 K. In addition, the vibration-rotation temperature of the Swan bands of the C2 radical was determined to be between 4500 and 7000 K, using an exact theoretical model for simulating diatomic emission spectra. This temperature range is probably caused by the spatial inhomogeneity of the laser-induced plasma plume. Differences are pointed out in the role of ambient CO2 in a solid graphite target and in gas-phase breakdown plasma

  17. Evaluation of TeO2 content on the optical and spectroscopic properties of Yb3 +-doped calcium borotellurite glasses

    Science.gov (United States)

    Lima, A. M. O.; Gomes, J. F.; Hegeto, F. L.; Medina, A. N.; Steimacher, A.; Barboza, M. J.

    2018-03-01

    This paper reports the synthesis and the characterization of Yb3 +-doped calcium borotellurite (CaBTeX) glasses with composition 10CaF2-(29.5 - 0.4x)CaO-(60 - 0.6x)B2O3-xTeO2-0.5Yb2O3 (x = 10, 16, 22, 31 and 54 mol%). The results of XRD confirm the amorphous character of all the samples. The density, molar volume, refractive index and electronic polarizability values show an increase with TeO2 content. Otherwise, the optical band gap energy shows a decrease with the increase of TeO2 content. The replacement of CaO and B2O3 by TeO2 changes the glass structure, which decreases the excited Yb3 +/cm3 and, consequently, the luminescence intensity. The temperature dependence of luminescence was studied for all the samples up to 420 K. The fluorescence lifetime does not change significantly due to TeO2 addition. In addition, absorption and emission cross section were calculated and present high values as compared to other tellurite and phosphate glasses.

  18. Raman and optical spectroscopic studies of small-to-large polaron crossover in the perovskite manganese oxides

    International Nuclear Information System (INIS)

    Yoon, S.; Liu, H.L.; Schollerer, G.; Cooper, S.L.; Han, P.D.; Payne, D.A.; Cheong, S.; Fisk, Z.

    1998-01-01

    We present an optical reflectance and Raman-scattering study of the A 1-x A ' x MnO 3 system as a function of temperature and doping (0.2≤x≤0.5). The metal-semiconductor transition in the A 1-x A ' x MnO 3 system is characterized by a change from a diffusive electronic Raman-scattering response in the high-temperature paramagnetic phase, to a flat continuum scattering response in the low-temperature ferromagnetic phase. We interpret this change in the scattering response as a crossover from a small-polaron-dominated regime at high temperatures to a large-polaron-dominated low-temperature regime. Interestingly, we observe evidence for the coexistence of large and small polarons in the low-temperature ferromagnetic phase. We contrast these results with those obtained for EuB 6 , which is a low-T c magnetic semiconductor with similar properties to the manganites, but with a substantially reduced carrier density and polaron energy. copyright 1998 The American Physical Society

  19. Comparative study of quantitative phase imaging techniques for refractometry of optical fibers

    Science.gov (United States)

    de Dorlodot, Bertrand; Bélanger, Erik; Bérubé, Jean-Philippe; Vallée, Réal; Marquet, Pierre

    2018-02-01

    The refractive index difference profile of optical fibers is the key design parameter because it determines, among other properties, the insertion losses and propagating modes. Therefore, an accurate refractive index profiling method is of paramount importance to their development and optimization. Quantitative phase imaging (QPI) is one of the available tools to retrieve structural characteristics of optical fibers, including the refractive index difference profile. Having the advantage of being non-destructive, several different QPI methods have been developed over the last decades. Here, we present a comparative study of three different available QPI techniques, namely the transport-of-intensity equation, quadriwave lateral shearing interferometry and digital holographic microscopy. To assess the accuracy and precision of those QPI techniques, quantitative phase images of the core of a well-characterized optical fiber have been retrieved for each of them and a robust image processing procedure has been applied in order to retrieve their refractive index difference profiles. As a result, even if the raw images for all the three QPI methods were suffering from different shortcomings, our robust automated image-processing pipeline successfully corrected these. After this treatment, all three QPI techniques yielded accurate, reliable and mutually consistent refractive index difference profiles in agreement with the accuracy and precision of the refracted near-field benchmark measurement.

  20. Optical techniques for probing the excited state dynamics of quantum dot solids

    Energy Technology Data Exchange (ETDEWEB)

    Moroz, P.; Kholmicheva, N.; Razgoniaeva, N. [Center for Photochemical Sciences, Bowling Green State University, Bowling Green, OH 43402 (United States); Department of Physics, Bowling Green State University, Bowling Green, OH 43402 (United States); Burchfield, D. [Department of Chemistry, Bowling Green State University, Bowling Green, OH 43402 (United States); Sharma, N.; Acharya, A. [Department of Physics, Bowling Green State University, Bowling Green, OH 43402 (United States); Zamkov, M., E-mail: zamkovm@bgsu.edu [Center for Photochemical Sciences, Bowling Green State University, Bowling Green, OH 43402 (United States); Department of Physics, Bowling Green State University, Bowling Green, OH 43402 (United States)

    2016-06-01

    Highlights: • Optical techniques represent a powerful tool for probing exciton diffusion in QD solids. • Exciton dissociation in QD solids is caused by charge tunneling to traps and other dots. • Exciton and free-carrier lifetimes are given by fast and slow components of PL decay. • Surface PL offers valuable information on the type and density of traps in QD solids. - Abstract: Quantum dot (QD) solids represent an important class of functional materials that holds strong promise for future applications in technology. Their optoelectronic properties are determined by energy diffusion processes, which character can often be inferred from the temporal and spectral analysis of the film’s photoluminescence (PL). Here, optical techniques based on PL lifetime, bulk quenching, and temperature-dependent PL will be discussed. These techniques complement the electrical conductivity measurements by mapping the flow of optically induced excitons through undepleted, contact-free films with an unprecedented temporal and spatial resolution. By correlating the QD solid morphology with the ensuing photoluminescence (PL) dynamics, these methods allow estimating important transport characteristics, including exciton and charge carrier diffusion lengths, the rate of interparticle energy transfer, carrier mobility, and the exciton diffusivity. The review will cover most popular PL-based strategies and summarize the key experimental findings resulting from these works.

  1. Optical coherence tomography as an accurate inspection and quality evaluation technique in paper industry

    Science.gov (United States)

    Prykäri, Tuukka; Czajkowski, Jakub; Alarousu, Erkki; Myllylä, Risto

    2010-05-01

    Optical coherence tomography (OCT), a technique for the noninvasive imaging of turbid media, based on low-coherence interferometry, was originally developed for the imaging of biological tissues. Since the development of the technique, most of its applications have been related to the area of biomedicine. However, from early stages, the vertical resolution of the technique has already been improved to a submicron scale. This enables new possibilities and applications. This article presents the possible applications of OCT in paper industry, where submicron or at least a resolution close to one micron is required. This requirement comes from the layered structure of paper products, where layer thickness may vary from single microns to tens of micrometers. This is especially similar to the case with high-quality paper products, where several different coating layers are used to obtain a smooth surface structure and a high gloss. In this study, we demonstrate that optical coherence tomography can be used to measure and evaluate the quality of the coating layer of a premium glossy photopaper. In addition, we show that for some paper products, it is possible to measure across the entire thickness range of a paper sheet. Furthermore, we suggest that in addition to topography and tomography images of objects, it is possible to obtain information similar to gloss by tracking the magnitude of individual interference signals in optical coherence tomography.

  2. Spectroscopic study of the optical counterpart to the fast X-ray transient IGR J17544-2619 based on observations at the 1.5-m RTT-150 telescope

    Science.gov (United States)

    Bikmaev, I. F.; Nikolaeva, E. A.; Shimansky, V. V.; Galeev, A. I.; Zhuchkov, R. Ya.; Irtuganov, E. N.; Melnikov, S. S.; Sakhibullin, N. A.; Grebenev, S. A.; Sharipova, L. M.

    2017-10-01

    We present the results of our long-term photometric and spectroscopic observations at the Russian-Turkish RTT-150 telescope for the optical counterpart to one of the best-known sources, representatives of the class of fast X-ray transients, IGR J17544-2619. Based on our optical data, we have determined for the first time the orbital and physical parameters of the binary system by the methods of Doppler spectroscopy.We have calculated theoretical spectra of the optical counterpart by applying non- LTE corrections for selected lines and obtained the parameters of the stellar atmosphere ( T eff = 33 000 K, log g = 3.85, R = 9.5 R ⊙, and M = 23 M ⊙). The latter suggest that the optical star is not a supergiant as has been thought previously.

  3. Probing the interactions of bromchlorbuterol-HCl and phenylethanolamine A with HSA by multi-spectroscopic and molecular docking technique

    International Nuclear Information System (INIS)

    Bi, Shuyun; Zhao, Tingting; Zhou, Huifeng; Wang, Yu; Li, Zhihong

    2016-01-01

    Highlights: • Molecular docking showed that BCB/PEA was bound at sub-domain IIA of HSA. • Fluorescence lifetimes indicated that the quenching was a static quenching. • CD spectra showed that BCB/PEA changed the conformation of HSA. • The competitive binding between site markers and BCB/PEA was studied. • The mutual influence on the two drugs binding HSA was studied. - Abstract: Using fluorescence quenching, fluorescence lifetime, (UV + vis) absorption, circular dichroism (CD) and molecular docking technique, the interactions of human serum albumin (HSA) with bromchlorbuterol-HCl (BCB) and phenylethanolamine A (PEA) were investigated. The quenching rate constants and binding constants for BCB/PEA with HSA were determined at T = (292.15, 302.15 and 312.15) K respectively, which were all decreased with the increase of the temperature, showing not a dynamic quenching. The fluorescence lifetime of HSA with BCB/PEA had changed little compared to that of HSA alone (τ_0), further confirming that BCB/PEA quenching of intrinsic fluorescence of HSA is a static quenching. The effects of K"+, Ca"2"+, Cu"2"+, Zn"2"+ and Fe"3"+ on the binding were studied. The analysis of the thermodynamic parameters for BCB/(PEA + HSA) showed that BCB/PEA could bind to HSA via hydrophobic force. The binding distances were determined as 2.90 and 4.11 nm for (BCB + HSA) and (PEA + HSA) based on the Förster’s non-radiative energy transfer theory (FRET). Synchronous fluorescence and CD spectra indicated that the conformation of HSA was changed by BCB/PEA. The competitive studies for the drug with site marker suggested that both BCB and PEA were bound at Sudlow’s sites I (sub-domain IIA, also known as indometacin binding site) in HSA, and the results of the study of molecular docking also leads to the same conclusion. The competitive binding experiments for the two drugs were also performed, which further indicates that PEA and BCB could share the same binding site, and PEA has a much

  4. Tunable CsPbBr3/Cs4PbBr6 phase transformation and their optical spectroscopic properties.

    Science.gov (United States)

    Chen, Xiao; Chen, Daqin; Li, Junni; Fang, Gaoliang; Sheng, Hongchao; Zhong, Jiasong

    2018-04-24

    As a novel type of promising materials, metal halide perovskites are a rising star in the field of optoelectronics. On this basis, a new frontier of zero-dimensional perovskite-related Cs4PbBr6 with bright green emission and high stability has attracted an enormous amount of attention, even though its photoluminescence still requires to clarification. Herein, the controllable phase transformation between three-dimensional CsPbBr3 and zero-dimensional Cs4PbBr6 is easily achieved in a facile ligand-assisted supersaturated recrystallization synthesis procedure via tuning the amount of surfactants, and their unique optical properties are investigated and compared in detail. Both Cs4PbBr6 and CsPbBr3 produce remarkably intense green luminescence with quantum yields up to 45% and 80%, respectively; however, significantly different emitting behaviors are observed. The fluorescence lifetime of Cs4PbBr6 is much longer than that of CsPbBr3, and photo-blinking is easily detected in the Cs4PbBr6 product, proving that the zero-dimensional Cs4PbBr6 is indeed a highly luminescent perovskite-related material. Additionally, for the first time, tunable emissions over the visible-light spectral region are demonstrated to be achievable via halogen composition modulations in the Cs4PbX6 (X = Cl, Br, I) samples. Our study brings a simple method for the phase control of CsPbBr3/Cs4PbBr6 and demonstrates the intrinsic luminescence nature of the zero-dimensional perovskite-related Cs4PbX6 products.

  5. Spectroscopic Parameters of Lumbar Intervertebral Disc Material

    Science.gov (United States)

    Terbetas, G.; Kozlovskaja, A.; Varanius, D.; Graziene, V.; Vaitkus, J.; Vaitkuviene, A.

    2009-06-01

    There are numerous methods of investigating intervertebral disc. Visualization methods are widely used in clinical practice. Histological, imunohistochemical and biochemical methods are more used in scientific research. We propose that a new spectroscopic investigation would be useful in determining intervertebral disc material, especially when no histological specimens are available. Purpose: to determine spectroscopic parameters of intervertebral disc material; to determine emission spectra common for all intervertebral discs; to create a background for further spectroscopic investigation where no histological specimen will be available. Material and Methods: 20 patients, 68 frozen sections of 20 μm thickness from operatively removed intervertebral disc hernia were excited by Nd:YAG microlaser STA-01-TH third harmonic 355 nm light throw 0, 1 mm fiber. Spectrophotometer OceanOptics USB2000 was used for spectra collection. Mathematical analysis of spectra was performed by ORIGIN multiple Gaussian peaks analysis. Results: In each specimen of disc hernia were found distinct maximal spectral peaks of 4 types supporting the histological evaluation of mixture content of the hernia. Fluorescence in the spectral regions 370-700 nm was detected in the disc hernias. The main spectral component was at 494 nm and the contribution of the components with the peak wavelength values at 388 nm, 412 nm and 435±5 nm were varying in the different groups of samples. In comparison to average spectrum of all cases, there are 4 groups of different spectral signatures in the region 400-500 nm in the patient groups, supporting a clinical data on different clinical features of the patients. Discussion and Conclusion: besides the classical open discectomy, new minimally invasive techniques of treating intervertebral disc emerge (PLDD). Intervertebral disc in these techniques is assessed by needle, no histological specimen is taken. Spectroscopic investigation via fiber optics through the

  6. Influence of Nb content on the structural and optical properties of anatase TiO{sub 2} polycrystalline thin film by e-beam technique

    Energy Technology Data Exchange (ETDEWEB)

    Shah, A., E-mail: attaullah77@yahoo.com; Mahmood, Arshad; Aziz, Uzma; Rashid, Rashad; Raza, Qaiser; Ali, Zahid

    2016-09-01

    In this paper, we report the structural and optical properties of Nb-doped TiO{sub 2} thin films deposited by e-beam evaporation technique. After post annealing in air at 500 °C for 1 h, the samples were characterized by various techniques such as X-ray diffraction (XRD), Raman spectroscopy, UV–Vis spectrophotometry and spectroscopic Ellipsometer. Both XRD and Raman analyses indicate that the films were crystallized into the polycrystalline anatase TiO{sub 2} structure. However it was observed that the crystallinity of the films decreases with the addition of Nb atoms and tends to become amorphous at 20% Nb content in TiO{sub 2} film. Moreover, no new phases such as Nb{sub 2}O{sub 5}, NbO{sub 2} or Nb metal were observed. The band gap energy was found to decrease with the increasing of Nb concentration which was verified by ellipsometric study. Ellipsomtric measurements also indicate that refractive index (n) of the films decreases while extinction coefficient (k) increases with the increasing of Nb content. All these analyses elucidate that the incorporation of Nb atom into TiO{sub 2} may tune the structural and optical properties of TiO{sub 2} thin films. - Highlights: • The addition of Nb into TiO{sub 2} film has strongly influenced its physical properties. • Anatase polycrystalline Nb:TiO{sub 2} films were grown up to 15% Nb content. • The film becomes an amorphous at 20% Nb doping. • Band gap energy of TiO{sub 2} film was decreased with increasing of Nb content in the film. • The Optical constants (n, k) of Nb:TiO{sub 2} film were varied as a function of Nb content.

  7. Spectroscopic properties of Er3+/Yb3+ Co-doped zinc boro-tellurite glasses for 1.5 xB5m broadband optical amplifiers

    Science.gov (United States)

    Suthanthirakumar, P.; Karthikeyan, P.; Vijayakumar, R.; Marimuthu, K.

    2015-06-01

    A new series of Er3+/Yb3+ co-doped Zinc boro-tellurite glasses with the chemical composition (40-x-y)B2O3+ 25TeO2+20ZnO+15BaO+xYb2O3+yEr2O3 (where x = 0.1, 0.5, 1 and 3; y =1 in wt %) were prepared by melt quenching technique and their spectroscopic behavior were studied through UV-Vis-NIR absorption and NIR luminescence measurements. The bonding parameters (β ¯ and δ) and Judd-Ofelt (JO) intensity parameters Ωλ (λ=2, 4 and 6) have been calculated from the band positions of the absorption spectra. A broad near-infrared emission band at 1540 nm with a full width at half maximum around 80 nm was observed from the NIR luminescence spectra by monitoring an excitation at 980 nm. The absorption cross-section and emission cross-section for the4I13/2→4I15/2 transition of the Er3+ ions were also determined using McCumber theory and the results were discussed and reported.

  8. New Active Optical Technique Developed for Measuring Low-Earth-Orbit Atomic Oxygen Erosion of Polymers

    Science.gov (United States)

    Banks, Bruce A.; deGroh, Kim K.; Demko, Rikako

    2003-01-01

    Polymers such as polyimide Kapton (DuPont) and Teflon FEP (DuPont, fluorinated ethylene propylene) are commonly used spacecraft materials because of desirable properties such as flexibility, low density, and in the case of FEP, a low solar absorptance and high thermal emittance. Polymers on the exterior of spacecraft in the low-Earth-orbit (LEO) environment are exposed to energetic atomic oxygen. Atomic oxygen reaction with polymers causes erosion, which is a threat to spacecraft performance and durability. It is, therefore, important to understand the atomic oxygen erosion yield E (the volume loss per incident oxygen atom) of polymers being considered in spacecraft design. The most common technique for determining E is a passive technique based on mass-loss measurements of samples exposed to LEO atomic oxygen during a space flight experiment. There are certain disadvantages to this technique. First, because it is passive, data are not obtained until after the flight is completed. Also, obtaining the preflight and postflight mass measurements is complicated by the fact that many polymers absorb water and, therefore, the mass change due to water absorption can affect the E data. This is particularly true for experiments that receive low atomic oxygen exposures or for samples that have a very low E. An active atomic oxygen erosion technique based on optical measurements has been developed that has certain advantages over the mass-loss technique. This in situ technique can simultaneously provide the erosion yield data on orbit and the atomic oxygen exposure fluence, which is needed for erosion yield determination. In the optical technique, either sunlight or artificial light can be used to measure the erosion of semitransparent or opaque polymers as a result of atomic oxygen attack. The technique is simple and adaptable to a rather wide range of polymers, providing that they have a sufficiently high optical absorption coefficient. If one covers a photodiode with a

  9. A technique for measuring oxygen saturation in biological tissues based on diffuse optical spectroscopy

    Science.gov (United States)

    Kleshnin, Mikhail; Orlova, Anna; Kirillin, Mikhail; Golubiatnikov, German; Turchin, Ilya

    2017-07-01

    A new approach to optical measuring blood oxygen saturation was developed and implemented. This technique is based on an original three-stage algorithm for reconstructing the relative concentration of biological chromophores (hemoglobin, water, lipids) from the measured spectra of diffusely scattered light at different distances from the probing radiation source. The numerical experiments and approbation of the proposed technique on a biological phantom have shown the high reconstruction accuracy and the possibility of correct calculation of hemoglobin oxygenation in the presence of additive noise and calibration errors. The obtained results of animal studies have agreed with the previously published results of other research groups and demonstrated the possibility to apply the developed technique to monitor oxygen saturation in tumor tissue.

  10. Intraoperative Optical Coherence Tomography Imaging and Assessment of the Macula During Cataract Surgery: A Novel Technique.

    Science.gov (United States)

    Tripathy, Koushik; Chawla, Rohan; Kumawat, Babulal; Sharma, Yog Raj

    2016-09-01

    The authors describe a technique to qualitatively analyze the posterior segment during cataract surgery using intraoperative optical coherence tomography (iOCT). Macular iOCT can be done before and after intraocular lens implantation after the media is rendered clear following phacoemulsification. A handheld irrigating planoconcave contact lens is placed over the cornea with the operating microscope in retroillumination mode. After focusing the microscope and upon getting a clear view of the posterior segment, iOCT is switched on, centered at the macula, and focused. This technique enables the surgeon to intraoperatively analyze and document the macular morphology and vitreoretinal interface. Potential uses of this technique include intraoperative decision-making regarding concurrent use of anti-vascular endothelial growth factor agents or steroids in cases with dense cataracts where preoperative OCT is difficult. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:846-847.]. Copyright 2016, SLACK Incorporated.

  11. A novel optical investigation technique for railroad track inspection and assessment

    Science.gov (United States)

    Sabato, Alessandro; Beale, Christopher H.; Niezrecki, Christopher

    2017-04-01

    Track failures due to cross tie degradation or loss in ballast support may result in a number of problems ranging from simple service interruptions to derailments. Structural Health Monitoring (SHM) of railway track is important for safety reasons and to reduce downtime and maintenance costs. For this reason, novel and cost-effective track inspection technologies for assessing tracks' health are currently insufficient and needed. Advancements achieved in recent years in cameras technology, optical sensors, and image-processing algorithms have made machine vision, Structure from Motion (SfM), and three-dimensional (3D) Digital Image Correlation (DIC) systems extremely appealing techniques for extracting structural deformations and geometry profiles. Therefore, optically based, non-contact measurement techniques may be used for assessing surface defects, rail and tie deflection profiles, and ballast condition. In this study, the design of two camera-based measurement systems is proposed for crossties-ballast condition assessment and track examination purposes. The first one consists of four pairs of cameras installed on the underside of a rail car to detect the induced deformation and displacement on the whole length of the track's cross tie using 3D DIC measurement techniques. The second consists of another set of cameras using SfM techniques for obtaining a 3D rendering of the infrastructure from a series of two-dimensional (2D) images to evaluate the state of the track qualitatively. The feasibility of the proposed optical systems is evaluated through extensive laboratory tests, demonstrating their ability to measure parameters of interest (e.g. crosstie's full-field displacement, vertical deflection, shape, etc.) for assessment and SHM of railroad track.

  12. All-optical optoacoustic microscopy based on probe beam deflection technique

    Directory of Open Access Journals (Sweden)

    Saher M. Maswadi

    2016-09-01

    Full Text Available Optoacoustic (OA microscopy using an all-optical system based on the probe beam deflection technique (PBDT for detection of laser-induced acoustic signals was investigated as an alternative to conventional piezoelectric transducers. PBDT provides a number of advantages for OA microscopy including (i efficient coupling of laser excitation energy to the samples being imaged through the probing laser beam, (ii undistorted coupling of acoustic waves to the detector without the need for separation of the optical and acoustic paths, (iii high sensitivity and (iv ultrawide bandwidth. Because of the unimpeded optical path in PBDT, diffraction-limited lateral resolution can be readily achieved. The sensitivity of the current PBDT sensor of 22 μV/Pa and its noise equivalent pressure (NEP of 11.4 Pa are comparable with these parameters of the optical micro-ring resonator and commercial piezoelectric ultrasonic transducers. Benefits of the present prototype OA microscope were demonstrated by successfully resolving micron-size details in histological sections of cardiac muscle.

  13. All-optical optoacoustic microscopy based on probe beam deflection technique.

    Science.gov (United States)

    Maswadi, Saher M; Ibey, Bennett L; Roth, Caleb C; Tsyboulski, Dmitri A; Beier, Hope T; Glickman, Randolph D; Oraevsky, Alexander A

    2016-09-01

    Optoacoustic (OA) microscopy using an all-optical system based on the probe beam deflection technique (PBDT) for detection of laser-induced acoustic signals was investigated as an alternative to conventional piezoelectric transducers. PBDT provides a number of advantages for OA microscopy including (i) efficient coupling of laser excitation energy to the samples being imaged through the probing laser beam, (ii) undistorted coupling of acoustic waves to the detector without the need for separation of the optical and acoustic paths, (iii) high sensitivity and (iv) ultrawide bandwidth. Because of the unimpeded optical path in PBDT, diffraction-limited lateral resolution can be readily achieved. The sensitivity of the current PBDT sensor of 22 μV/Pa and its noise equivalent pressure (NEP) of 11.4 Pa are comparable with these parameters of the optical micro-ring resonator and commercial piezoelectric ultrasonic transducers. Benefits of the present prototype OA microscope were demonstrated by successfully resolving micron-size details in histological sections of cardiac muscle.

  14. Slowing techniques for loading a magneto-optical trap of CaF molecules

    Science.gov (United States)

    Truppe, Stefan; Fitch, Noah; Williams, Hannah; Hambach, Moritz; Sauer, Ben; Hinds, Ed; Tarbutt, Mike

    2016-05-01

    Ultracold molecules in a magneto-optical trap (MOT) are useful for testing fundamental physics and studying strongly-interacting quantum systems. With experiments starting with a relatively fast (50-200 m/s) buffer-gas beam, a primary concern is decelerating molecules to below the MOT capture velocity, typically 10 m/s. Direct laser cooling, where the molecules are slowed via momentum transfer from a chirped counter-propagating narrowband laser, is a natural choice. However, chirping the cooling and repump lasers requires precise control of multiple laser frequencies simultaneously. Another approach, called ``white-light slowing'' uses a broadband laser such that all fast molecules in the beam are decelerated. By addressing numerous velocities no chirping is needed. Unfortunately, both techniques have significant losses as molecules are transversely heated during the optical cycling. Ideally, the slowing method would provide simultaneous deceleration and transverse guiding. A newly developed technique, called Zeeman-Sisyphus deceleration, is potentially capable of both. Using permanent magnets and optical pumping, the number of scattered photons is reduced, lessening transverse heating and relaxing the repump requirements. Here we compare all three options for CaF.

  15. Using optical remote sensing techniques to track the development of ozone-induced stress

    Energy Technology Data Exchange (ETDEWEB)

    Meroni, Michele, E-mail: michele.meroni@unimib.i [Remote Sensing of Environmental Dynamics Laboratory, DISAT, University of Milan-Bicocca, Piazza della Scienza, 1, 20126 Milan (Italy); Panigada, Cinzia; Rossini, Micol [Remote Sensing of Environmental Dynamics Laboratory, DISAT, University of Milan-Bicocca, Piazza della Scienza, 1, 20126 Milan (Italy); Picchi, Valentina [CNR, Plant Virology Institute, Milan Unit, Milan (Italy); Department of Tree Science, Entomology and Plant Pathology ' G. Scaramuzzi' , University of Pisa, Pisa (Italy); Cogliati, Sergio; Colombo, Roberto [Remote Sensing of Environmental Dynamics Laboratory, DISAT, University of Milan-Bicocca, Piazza della Scienza, 1, 20126 Milan (Italy)

    2009-05-15

    In this paper, a literature review about optical remote sensing (RS) of O{sub 3} stress is presented. Studies on O{sub 3}-induced effects on vegetation reflectance have been conducted since late '70s based on the analysis of optical RS data. Literature review reveals that traditional RS techniques were able to detect changes in leaf and canopy reflectance related to O{sub 3}-induced stress when visible symptoms already occurred. Only recently, advanced RS techniques using hyperspectral sensors, demonstrated the feasibility of detecting the stress in its early phase by monitoring excess energy dissipation pathways such as chlorophyll fluorescence and non-photochemical quenching (NPQ). Steady-state fluorescence (Fs), measured by exploiting the Fraunhofer line depth principle and NPQ related xanthophyll-cycle, estimated through the photochemical reflectance index (PRI) responded to O{sub 3} fumigation before visible symptoms occurred. This opens up new possibilities for the early detection of vegetation O{sub 3} stress by means of hyperspectral RS. - Possibilities for the early detection of vegetation O{sub 3} stress by means of optical remote sensing are discussed.

  16. High performance optical encryption based on computational ghost imaging with QR code and compressive sensing technique

    Science.gov (United States)

    Zhao, Shengmei; Wang, Le; Liang, Wenqiang; Cheng, Weiwen; Gong, Longyan

    2015-10-01

    In this paper, we propose a high performance optical encryption (OE) scheme based on computational ghost imaging (GI) with QR code and compressive sensing (CS) technique, named QR-CGI-OE scheme. N random phase screens, generated by Alice, is a secret key and be shared with its authorized user, Bob. The information is first encoded by Alice with QR code, and the QR-coded image is then encrypted with the aid of computational ghost imaging optical system. Here, measurement results from the GI optical system's bucket detector are the encrypted information and be transmitted to Bob. With the key, Bob decrypts the encrypted information to obtain the QR-coded image with GI and CS techniques, and further recovers the information by QR decoding. The experimental and numerical simulated results show that the authorized users can recover completely the original image, whereas the eavesdroppers can not acquire any information about the image even the eavesdropping ratio (ER) is up to 60% at the given measurement times. For the proposed scheme, the number of bits sent from Alice to Bob are reduced considerably and the robustness is enhanced significantly. Meantime, the measurement times in GI system is reduced and the quality of the reconstructed QR-coded image is improved.

  17. Using optical remote sensing techniques to track the development of ozone-induced stress

    International Nuclear Information System (INIS)

    Meroni, Michele; Panigada, Cinzia; Rossini, Micol; Picchi, Valentina; Cogliati, Sergio; Colombo, Roberto

    2009-01-01

    In this paper, a literature review about optical remote sensing (RS) of O 3 stress is presented. Studies on O 3 -induced effects on vegetation reflectance have been conducted since late '70s based on the analysis of optical RS data. Literature review reveals that traditional RS techniques were able to detect changes in leaf and canopy reflectance related to O 3 -induced stress when visible symptoms already occurred. Only recently, advanced RS techniques using hyperspectral sensors, demonstrated the feasibility of detecting the stress in its early phase by monitoring excess energy dissipation pathways such as chlorophyll fluorescence and non-photochemical quenching (NPQ). Steady-state fluorescence (Fs), measured by exploiting the Fraunhofer line depth principle and NPQ related xanthophyll-cycle, estimated through the photochemical reflectance index (PRI) responded to O 3 fumigation before visible symptoms occurred. This opens up new possibilities for the early detection of vegetation O 3 stress by means of hyperspectral RS. - Possibilities for the early detection of vegetation O 3 stress by means of optical remote sensing are discussed.

  18. Two Organic Cation Salts Containing Tetra(isothiocyanatecobaltate(II: Synthesis, Crystal Structures, Spectroscopic, Optical and Magnetic Properties

    Directory of Open Access Journals (Sweden)

    Zheng Zhang

    2017-03-01

    Full Text Available Single crystals of two hybrid organic-inorganic molecular solids, benzyl pyridinium tetra(isothiocyanatecobalt ([BzPy]2[Co(NCS4] (1 and benzyl quinolinium tetra(isothiocyanatecobalt ([BzQl]2[Co(NCS4] (2, were grown using a slow evaporation growth technique at room temperature and their IR, UV-Vis, X-ray crystal structures, luminescence, and magnetism were reported. The crystal structural analysis revealed that two molecular solids crystallize in the monoclinic space group P21/c of 1 and P21/n of 2. The cations form a dimer through weak C–H···π/π···π interactions in 1 and 2, and the adjacent cation (containing N(6 atom in 2 forms a columnar structure through π···π weak interactions between the quinoline and benzene rings, while the anions in 1 form a layer structure via short S···Co interactions. The anions (A and cations (C are arranged alternatively into a column in the sequence of ···A–CC–A–CC–A··· for 1, while the two anions and cationic dimer in 2 form an alliance by the C–H···π, C–H···S and C–H···N hydrogen bonds. A weak S···π interaction was found in 1 and 2. The two molecular solids show a broad fluorescence emission around 400 nm in the solid state at room temperature, and weak antiferromagnetic coupling behavior when the temperature is lowered.

  19. The VANDELS ESO spectroscopic survey

    Science.gov (United States)

    McLure, R. J.; Pentericci, L.; Cimatti, A.; Dunlop, J. S.; Elbaz, D.; Fontana, A.; Nandra, K.; Amorin, R.; Bolzonella, M.; Bongiorno, A.; Carnall, A. C.; Castellano, M.; Cirasuolo, M.; Cucciati, O.; Cullen, F.; De Barros, S.; Finkelstein, S. L.; Fontanot, F.; Franzetti, P.; Fumana, M.; Gargiulo, A.; Garilli, B.; Guaita, L.; Hartley, W. G.; Iovino, A.; Jarvis, M. J.; Juneau, S.; Karman, W.; Maccagni, D.; Marchi, F.; Mármol-Queraltó, E.; Pompei, E.; Pozzetti, L.; Scodeggio, M.; Sommariva, V.; Talia, M.; Almaini, O.; Balestra, I.; Bardelli, S.; Bell, E. F.; Bourne, N.; Bowler, R. A. A.; Brusa, M.; Buitrago, F.; Caputi, K. I.; Cassata, P.; Charlot, S.; Citro, A.; Cresci, G.; Cristiani, S.; Curtis-Lake, E.; Dickinson, M.; Fazio, G. G.; Ferguson, H. C.; Fiore, F.; Franco, M.; Fynbo, J. P. U.; Galametz, A.; Georgakakis, A.; Giavalisco, M.; Grazian, A.; Hathi, N. P.; Jung, I.; Kim, S.; Koekemoer, A. M.; Khusanova, Y.; Le Fèvre, O.; Lotz, J. M.; Mannucci, F.; Maltby, D. T.; Matsuoka, K.; McLeod, D. J.; Mendez-Hernandez, H.; Mendez-Abreu, J.; Mignoli, M.; Moresco, M.; Mortlock, A.; Nonino, M.; Pannella, M.; Papovich, C.; Popesso, P.; Rosario, D. P.; Salvato, M.; Santini, P.; Schaerer, D.; Schreiber, C.; Stark, D. P.; Tasca, L. A. M.; Thomas, R.; Treu, T.; Vanzella, E.; Wild, V.; Williams, C. C.; Zamorani, G.; Zucca, E.

    2018-05-01

    VANDELS is a uniquely-deep spectroscopic survey of high-redshift galaxies with the VIMOS spectrograph on ESO's Very Large Telescope (VLT). The survey has obtained ultra-deep optical (0.48 studies. Using integration times calculated to produce an approximately constant signal-to-noise ratio (20 motivation, survey design and target selection.

  20. Temperature measurement of plasma-assisted flames: comparison between optical emission spectroscopy and 2-color laser induced fluorescence techniques

    KAUST Repository

    Lacoste, Deanna A.

    2015-03-30

    Accurate thermometry of highly reactive environments, such as plasma-assisted combustion, is challenging. With the help of conical laminar premixed methane-air flames, this study compares two thermometry techniques for the temperature determination in a combustion front enhanced by nanosecond repetitively pulsed (NRP) plasma discharges. Based on emission spectroscopic analysis, the results show that the rotational temperature of CH(A) gives a reasonable estimate for the adiabatic flame temperature, only for lean and stoichiometric conditions. The rotational temperature of N2(C) is found to significantly underestimate the flame temperature. The 2-color OH-PLIF technique gives correct values of the flame temperature.

  1. Temperature measurement of plasma-assisted flames: comparison between optical emission spectroscopy and 2-color laser induced fluorescence techniques

    KAUST Repository

    Lacoste, Deanna A.; Heitz, Sylvain A.; Moeck, Jonas P.

    2015-01-01

    Accurate thermometry of highly reactive environments, such as plasma-assisted combustion, is challenging. With the help of conical laminar premixed methane-air flames, this study compares two thermometry techniques for the temperature determination in a combustion front enhanced by nanosecond repetitively pulsed (NRP) plasma discharges. Based on emission spectroscopic analysis, the results show that the rotational temperature of CH(A) gives a reasonable estimate for the adiabatic flame temperature, only for lean and stoichiometric conditions. The rotational temperature of N2(C) is found to significantly underestimate the flame temperature. The 2-color OH-PLIF technique gives correct values of the flame temperature.

  2. Order-disorder phase transformations in quaternary pyrochlore oxide system: Investigated by X-ray diffraction, transmission electron microscopy and Raman spectroscopic techniques

    International Nuclear Information System (INIS)

    Radhakrishnan, A.N.; Prabhakar Rao, P.; Sibi, K.S.; Deepa, M.; Koshy, Peter

    2009-01-01

    Order-disorder transformations in a quaternary pyrochlore oxide system, Ca-Y-Zr-Ta-O, were studied by powder X-ray diffraction (XRD) method, transmission electron microscope (TEM) and FT-NIR Raman spectroscopic techniques. The solid solutions in different ratios, 4:1, 2:1, 1:1, 1:2, 1:4, 1:6, of CaTaO 3.5 and YZrO 3.5 were prepared by the conventional high temperature ceramic route. The XRD results and Rietveld analysis revealed that the crystal structure changed from an ordered pyrochlore structure to a disordered defect fluorite structure as the ratios of the solid solutions of CaTaO 3.5 and YZrO 3.5 were changed from 4:1 to 1:4. This structural transformation in the present system is attributed to the lowering of the average cation radius ratio, r A /r B as a result of progressive and simultaneous substitution of larger cation Ca 2+ for Y 3+ at A sites and smaller cation Ta 5+ for Zr 4+ at B sites. Raman spectroscopy and TEM analysis corroborated the XRD results. - Graphical abstract: Selected area electron diffraction (SAED) patterns showed highly ordered diffraction maxima with characteristic superlattice weak diffraction spots of the pyrochlore structure for (a) Ca 0.6 7Y 1.33 Zr 1.33 Ta 0.33 O 7 (C2YZT2) and bright diffraction maxima arranged in a ring pattern of the fluorite structure for (b) Ca 0.29 7Y 1.71 Zr 1.71 Ta 0.29 O 7 (CY6Z6T).

  3. Use of Spectroscopic, Zeta Potential and Molecular Dynamic Techniques to Study the Interaction between Human Holo-Transferrin and Two Antagonist Drugs: Comparison of Binary and Ternary Systems

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Saberi

    2012-03-01

    Full Text Available For the first time, the binding of ropinirole hydrochloride (ROP and aspirin (ASA to human holo-transferrin (hTf has been investigated by spectroscopic approaches (fluorescence quenching, synchronous fluorescence, time-resolved fluorescence, three-dimensional fluorescence, UV-vis absorption, circular dichroism, resonance light scattering, as well as zeta potential and molecular modeling techniques, under simulated physiological conditions. Fluorescence analysis was used to estimate the effect of the ROP and ASA drugs on the fluorescence of hTf as well as to define the binding and quenching properties of binary and ternary complexes. The synchronized fluorescence and three-dimensional fluorescence spectra demonstrated some micro-environmental and conformational changes around the Trp and Tyr residues with a faint red shift. Thermodynamic analysis displayed the van der Waals forces and hydrogen bonds interactions are the major acting forces in stabilizing the complexes. Steady-state and time-resolved fluorescence data revealed that the fluorescence quenching of complexes are static mechanism. The effect of the drugs aggregating on the hTf resulted in an enhancement of the resonance light scattering (RLS intensity. The average binding distance between were computed according to the forster non-radiation energy transfer theory. The circular dichroism (CD spectral examinations indicated that the binding of the drugs induced a conformational change of hTf. Measurements of the zeta potential indicated that the combination of electrostatic and hydrophobic interactions between ROP, ASA and hTf formed micelle-like clusters. The molecular modeling confirmed the experimental results. This study is expected to provide important insight into the interaction of hTf with ROP and ASA to use in various toxicological and therapeutic processes.

  4. Optical characterization of porcine articular cartilage using a polarimetry technique with differential Mueller matrix formulism.

    Science.gov (United States)

    Chang, Ching-Min; Lo, Yu-Lung; Tran, Nghia-Khanh; Chang, Yu-Jen

    2018-03-20

    A method is proposed for characterizing the optical properties of articular cartilage sliced from a pig's thighbone using a Stokes-Mueller polarimetry technique. The principal axis angle, phase retardance, optical rotation angle, circular diattenuation, diattenuation axis angle, linear diattenuation, and depolarization index properties of the cartilage sample are all decoupled in the proposed analytical model. Consequently, the accuracy and robustness of the extracted results are improved. The glucose concentration, collagen distribution, and scattering properties of samples from various depths of the articular cartilage are systematically explored via an inspection of the related parameters. The results show that the glucose concentration and scattering effect are both enhanced in the superficial region of the cartilage. By contrast, the collagen density increases with an increasing sample depth.

  5. A dynamic plasmonic manipulation technique assisted by phase modulation of an incident optical vortex beam

    International Nuclear Information System (INIS)

    Yuan, G H; Wang, Q; Tan, P S; Lin, J; Yuan, X-C

    2012-01-01

    A novel phase modulation method for dynamic manipulation of surface plasmon polaritons (SPPs) with a phase engineered optical vortex (OV) beam illuminating on nanoslits is experimentally demonstrated. Because of the unique helical phase carried by an OV beam, dynamic control of SPP multiple focusing and standing wave generation is realized by changing the OV beam’s topological charge constituent with the help of a liquid-crystal spatial light modulator. Measurement of SPP distributions with near-field scanning optical microscopy showed an excellent agreement with numerical predictions. The proposed phase modulation technique for manipulating SPPs features has seemingly dynamic and reconfigurable advantages, with profound potential for development of SPP coupling, routing, multiplexing and high-resolution imaging devices on plasmonic chips. (paper)

  6. Construction and Optical Testing of Inflatable Membrane Mirror Using Structured Light Technique

    Directory of Open Access Journals (Sweden)

    Felipe Patiño-Jiménez

    2015-01-01

    Full Text Available Construction and characterization of an inflatable mirror prototype made out of flexible polymeric membranes are being presented. Surfaces were curved by imposing a slight excess of air pressure. Lightweighted, lowcost, and commercially available materials were selected in order to produce solar concentration elements at competitive prices. In this sense, large-area, image-forming mirrors with low optical acuity were achieved by concentration purposes. Optical characterization of the mirror’s shape at a given pressure or curvature radius was done by means of a structuredlight technique with a resolution of 0.1 mm finding a conical shape acquired by the inflated mirror as the best approximation. Concentration ratio achieved for a focal length of 5068 mm was of 25.1 suns, making a promising approach for lowering initial investment costs in applications such as hot-water, parabolic dish with Stirling engines, or concentrated photovoltaic electricity generation.

  7. OSM-Classic : An optical imaging technique for accurately determining strain

    Science.gov (United States)

    Aldrich, Daniel R.; Ayranci, Cagri; Nobes, David S.

    OSM-Classic is a program designed in MATLAB® to provide a method of accurately determining strain in a test sample using an optical imaging technique. Measuring strain for the mechanical characterization of materials is most commonly performed with extensometers, LVDT (linear variable differential transistors), and strain gauges; however, these strain measurement methods suffer from their fragile nature and it is not particularly easy to attach these devices to the material for testing. To alleviate these potential problems, an optical approach that does not require contact with the specimen can be implemented to measure the strain. OSM-Classic is a software that interrogates a series of images to determine elongation in a test sample and hence, strain of the specimen. It was designed to provide a graphical user interface that includes image processing with a dynamic region of interest. Additionally, the stain is calculated directly while providing active feedback during the processing.

  8. Optical asymmetric cryptography based on elliptical polarized light linear truncation and a numerical reconstruction technique.

    Science.gov (United States)

    Lin, Chao; Shen, Xueju; Wang, Zhisong; Zhao, Cheng

    2014-06-20

    We demonstrate a novel optical asymmetric cryptosystem based on the principle of elliptical polarized light linear truncation and a numerical reconstruction technique. The device of an array of linear polarizers is introduced to achieve linear truncation on the spatially resolved elliptical polarization distribution during image encryption. This encoding process can be characterized as confusion-based optical cryptography that involves no Fourier lens and diffusion operation. Based on the Jones matrix formalism, the intensity transmittance for this truncation is deduced to perform elliptical polarized light reconstruction based on two intensity measurements. Use of a quick response code makes the proposed cryptosystem practical, with versatile key sensitivity and fault tolerance. Both simulation and preliminary experimental results that support theoretical analysis are presented. An analysis of the resistance of the proposed method on a known public key attack is also provided.

  9. Detection of Biomass in New York City Aerosols: Light Scattering and Optical Fluorescence Techniques

    Science.gov (United States)

    Niebauer, M.; Alimova, A.; Katz, A.; Xu, M.; Rudolph, E.; Steiner, J.; Alfano, R. R.

    2005-12-01

    Optical spectroscopy is an ideal method for detecting bacteria and spores in real time. Optical fluorescence spectroscopy examination of New York City aerosols is used to quantify the mass of bacteria spores present in air masses collected at 14 liters/minute onto silica fiber filters, and on silica fiber ribbons using an Environmental Beta Attenuation Monitor manufactured by MetOne Instruments configured for the PM2.5 fraction. Dipicolinic acid (DPA), a molecule found primarily in bacterial spores, is the most characteristic component of spores in trial experiments on over 200 collected aerosol samples. DPA is extracted from the spores using a heat bath and chelated with Terbium. The DPA:Tb is detected by measuring its characteristic fluorescence with emission bands at 490, 545 and 585 nm for 270 nm excitation. Light scattering also measures the size distribution for a number of a variety of bacteria - Bacillus subtilis (rod shaped), Staphylococcus aureus (spherical) and Pseudomonas aeruginosa (short rods) establishing that optical techniques satisfactorily distinguish populations based on their variable morphology. Size and morphology are obtained by applying a variation of the Gaussian Ray Approximation theory of anomalous diffraction theory to an analysis of the transmission spectra in the range of 0.4 to 1.0 microns. In test experiments, the refractive index of the inner spore core of Bacillus subtilis decreases from 1.51 to 1.39 while the spore radius enlarges from 0.38 to 0.6 micrometers. Optical determinations are verified by oil-immersion techniques and by scanning electron microscope measurements. Characterization of spores, germinating spore materials, and bacteria is considered vital to tracing bacteria in the environment, for the development of life-detection systems for planetary exploration, monitoring pathogens in environmental systems, and for the preparation of anti-terrorism strategies.

  10. Measurements and properties of ice particles and carbon dioxide bubbles in aqueous mixture utilizing optical techniques

    Science.gov (United States)

    Diallo, Amadou O.

    Optical techniques are used to determine the size, shape and many other properties of particles ranging from the micro to a nano-level. These techniques have endless applications. This research is based on a project assigned by a "Vendor" that wants anonymity. The Leica optical microscope and the Dark Field Polarizing Metallurgical Microscope is used to determine the size and count of ice crystals (Vendors products) in multiple time frames. Since the ice temperature influences, its symmetry and the shape is subject to changes at room temperature (300 K) and the atmospheric pressure that is exerted on the ice crystals varies. The ice crystals are in a mixture of water, electrolytes and carbon dioxide with the optical spectroscopy (Qpod2) and Spectra suite, the optical density of the ice crystals is established from the absorbance and transmission measurements. The optical density in this case is also referred to as absorption; it is plotted with respect to a frequency (GHz), wavelength (nm) or Raman shift (1/cm) which shows the light colliding with the ice particles and CO2. Depending on the peaks positions, it is possible to profile the ice crystal sizes using a mean distribution plots. The region of absorbency wavelength expected for the ice is in the visible range; the water molecules in the (UV) Ultra-violet range and the CO2 in the (IR) infrared region. It is also possible to obtain the reflection and transmission output as a percentage change with the wavelengths ranging from 200 to 1100 nm. The refractive index of the ice can be correlated to the density based on the optical acoustic theorem, or Mie Scattering Theory. The viscosity of the ice crystals and the solutions from which the ice crystals are made of as well are recorded with the SV-10 viscometer. The baseline viscosity is used as reference and set lower than that of the ice crystals. The Zeta potential of the particles present in the mixture are approximated by first finding the viscosity of the

  11. XRF, μ-XRD and μ-spectroscopic techniques for revealing the composition and structure of paint layers on polychrome sculptures after multiple restorations.

    Science.gov (United States)

    Franquelo, M L; Duran, A; Castaing, J; Arquillo, D; Perez-Rodriguez, J L

    2012-01-30

    This paper presents the novel application of recently developed analytical techniques to the study of paint layers on sculptures that have been restored/repainted several times across centuries. Analyses were performed using portable XRF, μ-XRD and μ-Raman instruments. Other techniques, such as optical microscopy, SEM-EDX and μ-FTIR, were also used. Pigments and other materials including vermilion, minium, red lac, ivory black, lead white, barium white, zinc white (zincite), titanium white (rutile and anatase), lithopone, gold and brass were detected. Pigments from both ancient and modern times were found due to the different restorations/repaintings carried out. μ-Raman was very useful to characterise some pigments that were difficult to determine by μ-XRD. In some cases, pigments identification was only possible by combining results from the different analytical techniques used in this work. This work is the first article devoted to the study of sculpture cross-section samples using laboratory-made μ-XRD systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Classification of remotely sensed data using OCR-inspired neural network techniques. [Optical Character Recognition

    Science.gov (United States)

    Kiang, Richard K.

    1992-01-01

    Neural networks have been applied to classifications of remotely sensed data with some success. To improve the performance of this approach, an examination was made of how neural networks are applied to the optical character recognition (OCR) of handwritten digits and letters. A three-layer, feedforward network, along with techniques adopted from OCR, was used to classify Landsat-4 Thematic Mapper data. Good results were obtained. To overcome the difficulties that are characteristic of remote sensing applications and to attain significant improvements in classification accuracy, a special network architecture may be required.

  13. Alternative technique for biodiesel quality control using an optical fiber long-period grating sensor

    International Nuclear Information System (INIS)

    Falate, Rosane; Nike, Karen; Costa Neto, Pedro Ramos da; Cacao Junior, Eduardo; Muller, Marcia; Kalinowski, Hypolito Jose; Fabris, Jose Luis

    2007-01-01

    We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method. (author)

  14. A simple technique to facilitate treatment of urethral strictures with optical internal urethrotomy.

    Science.gov (United States)

    Stamatiou, Konstantinos; Papadatou, Aggeliki; Moschouris, Hippocrates; Kornezos, Ioannis; Pavlis, Anargiros; Christopoulos, Georgios

    2014-01-01

    Urethral stricture is a common condition that can lead to serious complications such as urinary infections and renal insufficiency secondary to urinary retention. Treatment options include catheterization, urethroplasty, endoscopic internal urethrotomy, and dilation. Optical internal urethrotomy offers faster recovery, minimal scarring, and less risk of infection, although recurrence is possible. However, technical difficulties associated with poor visualization of the stenosis or of the urethral lumen may increase procedural time and substantially increase the failure rates of internal urethrotomy. In this report we describe a technique for urethral catheterization via a suprapubic, percutaneous approach through the urinary bladder in order to facilitate endoscopic internal urethrotomy.

  15. A Simple Technique to Facilitate Treatment of Urethral Strictures with Optical Internal Urethrotomy

    Directory of Open Access Journals (Sweden)

    Konstantinos Stamatiou

    2014-01-01

    Full Text Available Urethral stricture is a common condition that can lead to serious complications such as urinary infections and renal insufficiency secondary to urinary retention. Treatment options include catheterization, urethroplasty, endoscopic internal urethrotomy, and dilation. Optical internal urethrotomy offers faster recovery, minimal scarring, and less risk of infection, although recurrence is possible. However, technical difficulties associated with poor visualization of the stenosis or of the urethral lumen may increase procedural time and substantially increase the failure rates of internal urethrotomy. In this report we describe a technique for urethral catheterization via a suprapubic, percutaneous approach through the urinary bladder in order to facilitate endoscopic internal urethrotomy.

  16. Development of a Direct Fabrication Technique for Full-Shell X-Ray Optics

    Science.gov (United States)

    Gubarev, M.; Kolodziejczak, J. K.; Griffith, C.; Roche, J.; Smith, W. S.; Kester, T.; Atkins, C.; Arnold, W.; Ramsey, B.

    2016-01-01

    Future astrophysical missions will require fabrication technology capable of producing high angular resolution x-ray optics. A full-shell direct fabrication approach using modern robotic polishing machines has the potential for producing high resolution, light-weight and affordable x-ray mirrors that can be nested to produce large collecting area. This approach to mirror fabrication, based on the use of the metal substrates coated with nickel phosphorous alloy, is being pursued at MSFC. The design of the polishing fixtures for the direct fabrication, the surface figure metrology techniques used and the results of the polishing experiments are presented.

  17. Nanomaterials-Based Optical Techniques for the Detection of Acetylcholinesterase and Pesticides

    Directory of Open Access Journals (Sweden)

    Ning Xia

    2014-12-01

    Full Text Available The large amount of pesticide residues in the environment is a threat to global health by inhibition of acetylcholinesterase (AChE. Biosensors for inhibition of AChE have been thus developed for the detection of pesticides. In line with the rapid development of nanotechnology, nanomaterials have attracted great attention and have been intensively studied in biological analysis due to their unique chemical, physical and size properties. The aim of this review is to provide insight into nanomaterial-based optical techniques for the determination of AChE and pesticides, including colorimetric and fluorescent assays and surface plasmon resonance.

  18. Measurement of micro moulded parts by Computed Tomography and comparison to optical and tactile techniques

    DEFF Research Database (Denmark)

    Yagüe, J.A.; Tosello, Guido; Carmignato, S

    2011-01-01

    This paper focuses on dimensional verification of two micro-injection moulded components, selected from actual industrial productions, using CT metrological tools. In addition to CT scanning, also a tactile Coordinate Measuring Machine (CMM) with sub-micrometer uncertainty and an Optical Coordinate...... Measuring Machine (OCMM) allowing fast measurements suitable for in-line quality control were employed as validation instruments. The experimental work carried out and the analysis of the results provide valuable conclusions about the advantages and drawbacks of using CT metrology in comparison with CMM...... and OCMM when these techniques are employed for quality control of micro moulded parts....

  19. Alternative technique for biodiesel quality control using an optical fiber long-period grating sensor

    Energy Technology Data Exchange (ETDEWEB)

    Falate, Rosane [Universidade Estadual de Ponta Grossa, PR (Brazil). Dept. de Informatica; Nike, Karen; Costa Neto, Pedro Ramos da [Universidade Tecnologica Federal do Parana, Curitiba (Brazil). Dept. de Quimica; Cacao Junior, Eduardo; Muller, Marcia; Kalinowski, Hypolito Jose; Fabris, Jose Luis [Universidade Tecnologica Federal do Parana, Curitiba (Brazil). Dept. de Fisica]. E-mail: fabris@utfpr.edu.br

    2007-07-01

    We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method. (author)

  20. An optical technique to measure the frequency and mode emission of tunable lasers

    International Nuclear Information System (INIS)

    Marchetti, S.; Simili, R.

    1988-01-01

    To use mode tunable lasers it is necessary to measure the laser frequency and the mode emission. This problem is very important when waveguide lasers are used. Normally this information is obtained by a heterodyne technique, but there are some difficulties to perform this method in a large electrical noise environment, when pulsed of radiofrequency lasers are used. This laser information was obtained by using an alternative low-cost optical system. With this apparatus the cavity pulling was measured and an upper limit for the linewidth of a radiofrequency, high pressure, line and mode-tunable, CO 2 laser was roughly estimated

  1. Investigation of the geometrical barrier in Bi-2212 using the magneto-optical technique

    International Nuclear Information System (INIS)

    Lin, Z.W.

    2000-01-01

    It has been found that the penetration of vortices into a weak pinning crystal is governed by a geometrical barrier and they form a dome-shaped flux profile across the crystal. Using the powerful magneto-optical technique, we investigated this geometrical barrier in a high-purity Bi 2 Sr 2 CaCu 2 O 8+x single-crystal platelet. Our results show that over the temperature range 20-70 K the dome-shaped profile is observed. Also, the influences of the edge shape and the roughness on the geometrical barrier are discussed. (author)

  2. Improved Optical Document Security Techniques Based on Volume Holography and Lippmann Photography

    Science.gov (United States)

    Bjelkhagen, Hans I.

    Optical variable devices (OVDs), such as holograms, are now common in the field of document security. Up until now mass-produced embossed holograms or other types of mass-produced OVDs are used not only for banknotes but also for personalized documents, such as passports, ID cards, travel documents, driving licenses, credit cards, etc. This means that identical OVDs are used on documents issued to individuals. Today, there is need for a higher degree of security on such documents and this chapter covers new techniques to make improved mass-produced or personalized OVDs.

  3. A microcontroller-based compensated optical proximity detector employing the switching-mode synchronous detection technique

    International Nuclear Information System (INIS)

    Rakshit, Anjan; Chatterjee, Amitava

    2012-01-01

    This paper describes the development of a microcontroller-based optical proximity detector that can provide a low-cost yet powerful obstacle-sensing mechanism for mobile robots. The system is developed with the switching-mode synchronous detection technique to provide satisfactory performance over a wide range of operating conditions and is developed with the facility of externally setting a threshold, for reliable operation. The system is dynamically compensated against ambient illumination variations. Experimental studies demonstrate how the minimum distance of activation can be varied with different choices of thresholds. (paper)

  4. Phonon and free-charge carrier properties in group-III nitride heterostructures investigated by spectroscopic ellipsometry and optical Hall effect

    Science.gov (United States)

    Schoeche, Stefan

    The material class of group-III nitrides gained tremendous technological importance for optoelectronic and high-power/high-frequency amplification devices. Tunability of the direct band gap from 0.65 eV (InN) to 6.2 eV (AlN) by alloying, high breakthrough voltages and intrinsic mobilities, as well as the formation of highly mobile 2d electron gases (2DEG) at heterointerfaces make these compounds ideal for many applications. GaN and Ga-rich alloys are well studied and current research is mainly device-oriented. For example, choice and quality of the gate dielectric significantly influence device performance in high-electron mobility transistors (HEMT) which utilize highly mobile 2DEGs at heterointerfaces. Experimental access to the 2DEG channel properties without influence from parasitic currents or contact properties are desirable. In- and Al-rich ternary alloys are less explored than Ga-rich compounds. For InN and In-rich alloys, while many material parameters such as stiffness constants or effective mass values are largely unknown, reliable p-type doping is a major challenge, also because p-type conducting channels are buried within highly conductive n-type material formed at the surface and interfaces preventing electrical characterization. For AlN and high-Al content alloys, doping mechanisms are not understood and reliable fabrication of material with high free-charge carrier (FCC) concentrations was achieved just recently. Difficulties to form ohmic contacts impair electrical measurements and optical characterization is impeded by lack of high-energy excitation sources. In this work, spectroscopic ellipsometry over the wide spectral range from the THz to VUV in combination with optical Hall effect (generalized ellipsometry with applied magnetic field) from THz to MIR are applied in order to investigate the phonon modes and FCC properties in group-III nitride heterostructures. Adequate model descriptions and analysis strategies are introduced which allow

  5. Narrow linewidth pulsed optical parametric oscillator

    Indian Academy of Sciences (India)

    Tunable narrow linewidth radiation by optical parametric oscillation has many applications, particularly in spectroscopic investigation. In this paper, different techniques such as injection seeding, use of spectral selecting element like grating, grating and etalon in combination, grazing angle of incidence, entangled cavity ...

  6. Enhanced optical band-gap of ZnO thin films by sol-gel technique

    Energy Technology Data Exchange (ETDEWEB)

    Raghu, P., E-mail: dpr3270@gmail.com; Naveen, C. S.; Shailaja, J.; Mahesh, H. M., E-mail: hm-mahesh@rediffmail.com [Thin Film and Solar Cell Laboratory, Department of Electronic Science, Bangalore University, Jnanabharathi, Bangalore -560056 (India)

    2016-05-06

    Transparent ZnO thin films were prepared using different molar concentration (0.1 M, 0.2 M & 0.8 M) of zinc acetate on soda lime glass substrates by the sol-gel spin coating technique. The optical properties revealed that the transmittance found to decrease with increase in molar concentration. Absorption edge showed that the higher concentration film has increasingly red shifted. An increased band gap energy of the thin films was found to be direct allowed transition of ∼3.9 eV exhibiting their relevance for photovoltaic applications. The extinction coefficient analysis revealed maximum transmittance with negligible absorption coefficient in the respective wavelengths. The results of ZnO thin film prepared by sol-gel technique reveal its suitability for optoelectronics and as a window layer in solar cell applications.

  7. Technique of fiber optics used to localize epidural space in piglets.

    Science.gov (United States)

    Ting, Chien-Kun; Chang, Yin

    2010-05-24

    Technique of loss-of-resistance in epidural block is commonly used for epidural anesthesia in humans with approximately 90% successful rate. However, it may be one of the most difficult procedures to learn for anesthesia residents in hospital. A two-wavelength (650 nm and 532 nm) fiber-optical method has been developed according to the characteristic reflectance spectra of ex-vivo porcine tissues, which are associated with the needle insertion to localize the epidural space (ES). In an in-vivo study in piglets showed that the reflected lights from ES and its surrounding tissue ligamentum flavum (LF) are highly distinguishable. This indicates that this technique has potential to localize the ES on the spot without the help of additional guiding assistance.

  8. Interactions between heavy metals and photosynthetic materials studied by optical techniques.

    Science.gov (United States)

    Ventrella, Andrea; Catucci, Lucia; Piletska, Elena; Piletsky, Sergey; Agostiano, Angela

    2009-11-01

    In this work studies on rapid inhibitory interactions between heavy metals and photosynthetic materials at different organization levels were carried out by optical assay techniques, investigating the possibility of applications in the heavy metal detection field. Spinach chloroplasts, thylakoids and Photosystem II proteins were employed as biotools in combination with colorimetric assays based on dichlorophenol indophenole (DCIP) photoreduction and on fluorescence emission techniques. It was found that copper and mercury demonstrated a strong and rapid photosynthetic activity inhibition, that varied from proteins to membranes, while other metals like nickel, cobalt and manganese produced only slight inhibition effects on all tested photosynthetic materials. By emission measurements, only copper was found to rapidly influence the photosynthetic material signals. These findings give interesting information about the rapid effects of heavy metals on isolated photosynthetic samples, and are in addition to the literature data concerning the effects of growth in heavy metal enriched media.

  9. Determination of free acidity in nuclear fuel reprocessing streams by fiber optic aided spectrophotometric technique

    International Nuclear Information System (INIS)

    Ganesh, S.; Velavendan, P.; Pandey, N.K.; Kamachi Mudali, U.; Natarajan, R.

    2014-01-01

    A fiber optic aided spectrophotometric technique has been developed for the determination of free acidity in nuclear fuel reprocessing streams. The developed method is simple, accurate and applicable to all ranges of nitric acid and heavy metal concentrations relevant to the purex process. The method is based on the formation of yellow colour with an acid-sensitive indicator such as chrome azurol s, the intensity of yellow colour is proportional to the acid concentration. The system obeys Lambert-Beer's law at 455 nm in the range of acidity 1-10 M of nitric acid. The results obtained are reproducible with standard deviation 2% and relative error is less than 3%. The results obtained by the developed technique are in good agreement with those obtained by the standard procedure. This method is adaptable for remote operation and on-line monitoring. (author)

  10. K-means-clustering-based fiber nonlinearity equalization techniques for 64-QAM coherent optical communication system.

    Science.gov (United States)

    Zhang, Junfeng; Chen, Wei; Gao, Mingyi; Shen, Gangxiang

    2017-10-30

    In this work, we proposed two k-means-clustering-based algorithms to mitigate the fiber nonlinearity for 64-quadrature amplitude modulation (64-QAM) signal, the training-sequence assisted k-means algorithm and the blind k-means algorithm. We experimentally demonstrated the proposed k-means-clustering-based fiber nonlinearity mitigation techniques in 75-Gb/s 64-QAM coherent optical communication system. The proposed algorithms have reduced clustering complexity and low data redundancy and they are able to quickly find appropriate initial centroids and select correctly the centroids of the clusters to obtain the global optimal solutions for large k value. We measured the bit-error-ratio (BER) performance of 64-QAM signal with different launched powers into the 50-km single mode fiber and the proposed techniques can greatly mitigate the signal impairments caused by the amplified spontaneous emission noise and the fiber Kerr nonlinearity and improve the BER performance.

  11. Self-centring technique for fibre optic microlens mounting using a concave cone-etched fibre

    International Nuclear Information System (INIS)

    Demagh, Nacer-Eddine; Guessoum, Assia; Zegari, Rabah; Gharbi, Tijani

    2011-01-01

    Several techniques of centring a microlens onto the fibre optic end face are studied. In most of them, microsphere lenses are centred with the aid of high-accuracy micro-positioners. This process is complicated with regard to the difficulty in manipulating microsphere lenses. In this paper, a simple and accurate self-centring method for mounting microsphere lenses using a concave cone etched fibre (Demagh et al 2006 Meas. Sci. Technol. 17 119–22) is described. This technique allows the centring of a wide variety of microlens radii, typically 7 µm to over 24 µm. The proposed process, however, is not affected by any spatial positioning control of microspheres. In over 85% of the attempts, the microsphere lenses were centred on the fibre axis to within 0.12 µm

  12. Circularly polarized light to study linear magneto-optics for ferrofluids: θ-scan technique

    Science.gov (United States)

    Meng, Xiangshen; Huang, Yan; He, Zhenghong; Lin, Yueqiang; Liu, Xiaodong; Li, Decai; Li, Jian; Qiu, Xiaoyan

    2018-06-01

    Circularly polarized light can be divided into two vertically linearly polarized light beams with  ±π/2 phase differences. In the presence of an external magnetic field, when circularly polarized light travels through a ferrofluid film, whose thickness is no more than that of λ/4 plate, magneto-optical, magnetic birefringence and dichroism effects cause the transmitted light to behave as elliptically polarized light. Using angular scan by a continuously rotating polarizer as analyzer, the angular (θ) distribution curve of relative intensity (T) corresponding to elliptically polarized light can be measured. From the T  ‑  θ curve having ellipsometry, the parameters such as the ratio of short to long axis, and angular orientation of the long axis to the vertical field direction can be obtained. Thus, magnetic birefringence and dichroism can be probed simultaneously by measuring magneto-optical, positive or negative birefringence and dichroism features from the transmission mode. The proposed method is called θ-scan technique, and can accurately determine sample stability, magnetic field direction, and cancel intrinsic light source ellipticity. This study may be helpful to further research done to ferrofluids and other similar colloidal samples with anisotropic optics.

  13. Optic neuropathy in thyroid eye disease: results of the balanced decompression technique.

    Science.gov (United States)

    Baril, Catherine; Pouliot, Denis; Molgat, Yvonne

    2014-04-01

    To determine the efficacy of combined endoscopic medial and external lateral orbital decompression for the treatment of compressive optic neuropathy (CON) in thyroid eye disease (TED). A retrospective review of all patients undergoing combined surgical orbital decompression for CON between 2000 and 2010 was conducted. Fifty-nine eyes of 34 patients undergoing combined surgical orbital decompression for CON. Clinical outcome measures included visual acuity, Hardy-Rand-Rittler (HRR) colour plate testing, relative afferent pupillary defect, intraocular pressure measurement, and Hertel exophthalmometry. A CON score was calculated preoperatively and postoperatively based on the visual acuity and the missed HRR plates. A higher CON score correlates with more severe visual dysfunction. All patients had improvement of their optic neuropathy after surgical decompression. CON score was calculated for 54 eyes and decreased significantly from a mean of 13.2 ± 10.35 preoperatively to a mean of 8.51 ± 10.24 postoperatively (p < 0.0001). Optic neuropathy was completely resolved in 93.22% (55/59 eyes). Eighteen of 34 patients (52.94%) experienced development of new-onset postoperative strabismus that required subsequent surgical intervention. Endoscopic medial combined with external lateral orbital decompression is an effective technique for the treatment of TED-associated CON. © 2013 Canadian Ophthalmological Society Published by Canadian Ophthalmological Society All rights reserved.

  14. Optical and Electrical Properties of Copper Oxide Thin Films Synthesized by Spray Pyrolysis Technique

    Directory of Open Access Journals (Sweden)

    S. S. Roy

    2015-08-01

    Full Text Available Copper oxide (CuO thin films have been synthesized on to glass substrates at different temperatures in the range 250-450 °C by spray pyrolysis technique from aqueous solution using cupric acetate Cu(CH3COO2·H2O as a precursor. The structure of the deposited CuO thin films characterized by X-ray diffraction, the surface morphology was observed by a scanning electron microscope, the presence of elements was detected by energy dispersive X-ray analysis, the optical transmission spectra was recorded by ultraviolet-visible spectroscopy and electrical resistivity was studied by Van-der Pauw method. All the CuO thin films, irrespective of growth temperature, showed a monoclinic structure with the main CuO (111 orientation, and the crystallite size was about 8.4784 Å for the thin film synthesized at 350 °C. The optical transmission of the as-deposited film is found to decrease with the increase of substrate temperature, the optical band gap of the thin films varies from 1.90 to 1.60 eV and the room temperature electrical resistivity varies from 30 to18 Ohm·cm for the films grown at different substrate temperatures.

  15. Effect of content silver and heat treatment temperature on morphological, optical, and electrical properties of ITO films by sol-gel technique

    Science.gov (United States)

    Mirzaee, Majid; Dolati, Abolghasem

    2014-09-01

    Silver-doped indium tin oxide thin films were synthesized using sol-gel dip-coating technique. The influence of different silver-dopant contents and annealing temperature on the electrical, optical, structural, and morphological properties of the films were characterized by means of four-point probe, UV-Vis spectroscopy, X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), and X-ray photoelectron spectroscope (XPS). XRD analysis confirmed the formation of cubic bixbyte structure of In2O3 with silver nanoparticles annealed at 350 °C. XPS analysis showed that divalent tin transformed to tetravalent tin through oxidization, and silver nanoparticles embedded into ITO matrix covered with silver oxide shell, resulting in high quality nanocomposite thin films. The embedment of polyvinylpyrrolidone inhibited the growth of silver nanoparticles and ITO annealed at 350 °C. Delafossite structure of tin-doped AgInO2 was found at higher annealing temperatures. XRD analysis and FESEM micrographs showed that the optimum temperature to prevent the formation of AgInO2 is 350 °C. The embedment of silver particles (5-10 nm) from reduction of silver ion in ITO thin films improved the electrical conductivity and optical transmittance of ITO nanolayers. The lowest stable sheet resistance of 1,952 Ω/Sq for a 321 nm thick and an average optical transmittance of 91.8 % in the visible region with a band gap of 3.43 eV were achieved for silver-doping content of 0.04 M.

  16. Coherent Pound-Drever-Hall technique for high resolution fiber optic strain sensor at very low light power

    Science.gov (United States)

    Wu, Mengxin; Liu, Qingwen; Chen, Jiageng; He, Zuyuan

    2017-04-01

    Pound-Drever-Hall (PDH) technique has been widely adopted for ultrahigh resolution fiber-optic sensors, but its performance degenerates seriously as the light power drops. To solve this problem, we developed a coherent PDH technique for weak optical signal detection, with which the signal-to-noise ratio (SNR) of demodulated PDH signal is dramatically improved. In the demonstrational experiments, a high resolution fiber-optic sensor using the proposed technique is realized, and n"-order strain resolution at a low light power down to -43 dBm is achieved, which is about 15 dB lower compared with classical PDH technique. The proposed coherent PDH technique has great potentials in longer distance and larger scale sensor networks.

  17. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique

    OpenAIRE

    Md. Rajibur Rahaman Khan; Shin-Won Kang

    2016-01-01

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal?s pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The...

  18. Optical design and analysis of carbon dioxide laser fusion systems using interferometry and fast Fourier transform techniques

    International Nuclear Information System (INIS)

    Viswanathan, V.K.

    1979-01-01

    The optical design and analysis of the LASL carbon dioxide laser fusion systems required the use of techniques that are quite different from the currently used method in conventional optical design problems. The necessity for this is explored and the method that has been successfully used at Los Alamos to understand these systems is discussed with examples. This method involves characterization of the various optical components in their mounts by a Zernike polynomial set and using fast Fourier transform techniques to propagate the beam, taking diffraction and other nonlinear effects that occur in these types of systems into account. The various programs used for analysis are briefly discussed

  19. Multivariate reference technique for quantitative analysis of fiber-optic tissue Raman spectroscopy.

    Science.gov (United States)

    Bergholt, Mads Sylvest; Duraipandian, Shiyamala; Zheng, Wei; Huang, Zhiwei

    2013-12-03

    We report a novel method making use of multivariate reference signals of fused silica and sapphire Raman signals generated from a ball-lens fiber-optic Raman probe for quantitative analysis of in vivo tissue Raman measurements in real time. Partial least-squares (PLS) regression modeling is applied to extract the characteristic internal reference Raman signals (e.g., shoulder of the prominent fused silica boson peak (~130 cm(-1)); distinct sapphire ball-lens peaks (380, 417, 646, and 751 cm(-1))) from the ball-lens fiber-optic Raman probe for quantitative analysis of fiber-optic Raman spectroscopy. To evaluate the analytical value of this novel multivariate reference technique, a rapid Raman spectroscopy system coupled with a ball-lens fiber-optic Raman probe is used for in vivo oral tissue Raman measurements (n = 25 subjects) under 785 nm laser excitation powers ranging from 5 to 65 mW. An accurate linear relationship (R(2) = 0.981) with a root-mean-square error of cross validation (RMSECV) of 2.5 mW can be obtained for predicting the laser excitation power changes based on a leave-one-subject-out cross-validation, which is superior to the normal univariate reference method (RMSE = 6.2 mW). A root-mean-square error of prediction (RMSEP) of 2.4 mW (R(2) = 0.985) can also be achieved for laser power prediction in real time when we applied the multivariate method independently on the five new subjects (n = 166 spectra). We further apply the multivariate reference technique for quantitative analysis of gelatin tissue phantoms that gives rise to an RMSEP of ~2.0% (R(2) = 0.998) independent of laser excitation power variations. This work demonstrates that multivariate reference technique can be advantageously used to monitor and correct the variations of laser excitation power and fiber coupling efficiency in situ for standardizing the tissue Raman intensity to realize quantitative analysis of tissue Raman measurements in vivo, which is particularly appealing in

  20. Satellite Angular Velocity Estimation Based on Star Images and Optical Flow Techniques

    Directory of Open Access Journals (Sweden)

    Giancarmine Fasano

    2013-09-01

    Full Text Available An optical flow-based technique is proposed to estimate spacecraft angular velocity based on sequences of star-field images. It does not require star identification and can be thus used to also deliver angular rate information when attitude determination is not possible, as during platform de tumbling or slewing. Region-based optical flow calculation is carried out on successive star images preprocessed to remove background. Sensor calibration parameters, Poisson equation, and a least-squares method are then used to estimate the angular velocity vector components in the sensor rotating frame. A theoretical error budget is developed to estimate the expected angular rate accuracy as a function of camera parameters and star distribution in the field of view. The effectiveness of the proposed technique is tested by using star field scenes generated by a hardware-in-the-loop testing facility and acquired by a commercial-off-the shelf camera sensor. Simulated cases comprise rotations at different rates. Experimental results are presented which are consistent with theoretical estimates. In particular, very accurate angular velocity estimates are generated at lower slew rates, while in all cases the achievable accuracy in the estimation of the angular velocity component along boresight is about one order of magnitude worse than the other two components.

  1. Advances in estimation methods of vegetation water content based on optical remote sensing techniques

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Quantitative estimation of vegetation water content(VWC) using optical remote sensing techniques is helpful in forest fire as-sessment,agricultural drought monitoring and crop yield estimation.This paper reviews the research advances of VWC retrieval using spectral reflectance,spectral water index and radiative transfer model(RTM) methods.It also evaluates the reli-ability of VWC estimation using spectral water index from the observation data and the RTM.Focusing on two main definitions of VWC-the fuel moisture content(FMC) and the equivalent water thickness(EWT),the retrieval accuracies of FMC and EWT using vegetation water indices are analyzed.Moreover,the measured information and the dataset are used to estimate VWC,the results show there are significant correlations among three kinds of vegetation water indices(i.e.,WSI,NDⅡ,NDWI1640,WI/NDVI) and canopy FMC of winter wheat(n=45).Finally,the future development directions of VWC detection based on optical remote sensing techniques are also summarized.

  2. ELECTRON BUNCH CHARACTERIZATION WITH SUBPICOSECOND RESOLUTION USING ELECTRO-OPTIC TECHNIQUE

    International Nuclear Information System (INIS)

    SEMERTZIDIS, Y.K.; CASTILLO, V.; LARSEN, R.; LAZARUS, D.M.; NIKAS, D.; OZBEN, C.; SRINIVASAN-RAO, T.; STILLMAN, A.; TSANG, T.; KOWALSKI, L.

    2001-01-01

    In the past decade, the bunch lengths of electrons in accelerators have decreased dramatically and are in the range off a few millimeters. Measurement of the length as well as the longitudinal profile of these short bunches have been a topic of research in a number of institutions. One of the techniques uses the electric field induced by the passage of electrons in the vicinity of a birefringent crystal to change its optical characteristics. Well-established electro-optic techniques can then be used to measure the temporal characteristics of the electron bunch. The inherent fast response of the crystal facilitates the measurement to femtosecond time resolution. However, the resolution in experiments so far has been limited to 70 ps, by the bandwidth of the detection equipment. Use of a streak camera can improve this resolution to a few picoseconds. In this paper we present a novel, non-invasive, single-shot approach to improve the resolution to tens of femtoseconds so that sub mm bunch length can be measured

  3. Optical properties of WO3 thin films using surface plasmon resonance technique

    International Nuclear Information System (INIS)

    Paliwal, Ayushi; Sharma, Anjali; Gupta, Vinay; Tomar, Monika

    2014-01-01

    Indigenously assembled surface plasmon resonance (SPR) technique has been exploited to study the thickness dependent dielectric properties of WO 3 thin films. WO 3 thin films (80 nm to 200 nm) have been deposited onto gold (Au) coated glass prism by sputtering technique. The structural, optical properties and surface morphology of the deposited WO 3 thin films were studied using X-ray diffraction, UV-visible spectrophotometer, Raman spectroscopy, and Scanning electron microscopy (SEM). XRD analysis shows that all the deposited WO 3 thin films are exhibiting preferred (020) orientation and Raman data indicates that the films possess single phase monoclinic structure. SEM images reveal the variation in grain size with increase in thickness. The SPR reflectance curves of the WO 3 /Au/prism structure were utilized to estimate the dielectric properties of WO 3 thin films at optical frequency (λ = 633 nm). As the thickness of WO 3 thin film increases from 80 nm to 200 nm, the dielectric constant is seen to be decreasing from 5.76 to 3.42, while the dielectric loss reduces from 0.098 to 0.01. The estimated value of refractive index of WO 3 film is in agreement to that obtained from UV-visible spectroscopy studies. The strong dispersion in refractive index is observed with wavelength of incident laser light

  4. Optical properties of WO{sub 3} thin films using surface plasmon resonance technique

    Energy Technology Data Exchange (ETDEWEB)

    Paliwal, Ayushi; Sharma, Anjali; Gupta, Vinay, E-mail: drguptavinay@gmail.com, E-mail: vgupta@physics.du.ac.in [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Tomar, Monika [Department of Physics, Miranda House, University of Delhi, Delhi 110007 (India)

    2014-01-28

    Indigenously assembled surface plasmon resonance (SPR) technique has been exploited to study the thickness dependent dielectric properties of WO{sub 3} thin films. WO{sub 3} thin films (80 nm to 200 nm) have been deposited onto gold (Au) coated glass prism by sputtering technique. The structural, optical properties and surface morphology of the deposited WO{sub 3} thin films were studied using X-ray diffraction, UV-visible spectrophotometer, Raman spectroscopy, and Scanning electron microscopy (SEM). XRD analysis shows that all the deposited WO{sub 3} thin films are exhibiting preferred (020) orientation and Raman data indicates that the films possess single phase monoclinic structure. SEM images reveal the variation in grain size with increase in thickness. The SPR reflectance curves of the WO{sub 3}/Au/prism structure were utilized to estimate the dielectric properties of WO{sub 3} thin films at optical frequency (λ = 633 nm). As the thickness of WO{sub 3} thin film increases from 80 nm to 200 nm, the dielectric constant is seen to be decreasing from 5.76 to 3.42, while the dielectric loss reduces from 0.098 to 0.01. The estimated value of refractive index of WO{sub 3} film is in agreement to that obtained from UV-visible spectroscopy studies. The strong dispersion in refractive index is observed with wavelength of incident laser light.

  5. 10-channel fiber array fabrication technique for parallel optical coherence tomography system

    Science.gov (United States)

    Arauz, Lina J.; Luo, Yuan; Castillo, Jose E.; Kostuk, Raymond K.; Barton, Jennifer

    2007-02-01

    Optical Coherence Tomography (OCT) shows great promise for low intrusive biomedical imaging applications. A parallel OCT system is a novel technique that replaces mechanical transverse scanning with electronic scanning. This will reduce the time required to acquire image data. In this system an array of small diameter fibers is required to obtain an image in the transverse direction. Each fiber in the array is configured in an interferometer and is used to image one pixel in the transverse direction. In this paper we describe a technique to package 15μm diameter fibers on a siliconsilica substrate to be used in a 2mm endoscopic probe tip. Single mode fibers are etched to reduce the cladding diameter from 125μm to 15μm. Etched fibers are placed into a 4mm by 150μm trench in a silicon-silica substrate and secured with UV glue. Active alignment was used to simplify the lay out of the fibers and minimize unwanted horizontal displacement of the fibers. A 10-channel fiber array was built, tested and later incorporated into a parallel optical coherence system. This paper describes the packaging, testing, and operation of the array in a parallel OCT system.

  6. Digital holographic interferometry: A novel optical calorimetry technique for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cavan, Alicia, E-mail: alicia.cavan@cdhb.health.nz [Department of Physics and Astronomy, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand and Christchurch Hospital, Private Bag 4710, Christchurch 8140 (New Zealand); Meyer, Juergen, E-mail: juergen@uw.edu [Department of Radiation Oncology, University of Washington, 1959 Northeast Pacific Street, Box 356043, Seattle, Washington 98195 (United States)

    2014-02-15

    Purpose: To develop and demonstrate the proof-of-principle of a novel optical calorimetry method to determine radiation absorbed dose in a transparent medium. Methods: The calorimetric property of water is measured during irradiation by means of an interferometer, which detects temperature-induced changes in the refractive index that can be mathematically related to absorbed dose. The proposed method uses a technique called digital holographic interferometry (DHI), which comprises an optical laser interferometer setup and consecutive physical reconstruction of the recorded wave fronts by means of the Fresnel transform. This paper describes the conceptual framework and provides the mathematical basis for DHI dosimetry. Dose distributions from a high dose rate Brachytherapy source were measured by a prototype optical setup to demonstrate the feasibility of the approach. Results: The developed DHI dosimeter successfully determined absorbed dose distributions in water in the region adjacent to a high dose rate Brachytherapy source. A temperature change of 0.0381 K across a distance of 6.8 mm near the source was measured, corresponding to a dose of 159.3 Gy. The standard deviation in a typical measurement set was ±3.45 Gy (corresponding to an uncertainty in the temperature value of ±8.3 × 10{sup −4} K). The relative dose fall off was in agreement with treatment planning system modeled data. Conclusions: First results with a prototype optical setup and a Brachytherapy source demonstrate the proof-of-principle of the approach. The prototype achieves high spatial resolution of approximately 3 × 10{sup −5} m. The general approach is fundamentally independent of the radiation type and energy. The sensitivity range determined indicates that the method is predominantly suitable for high dose rate applications. Further work is required to determine absolute dose in all three dimensions.

  7. Measuring higher order optical aberrations of the human eye: techniques and applications

    Directory of Open Access Journals (Sweden)

    L. Alberto V. Carvalho

    2002-11-01

    Full Text Available In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia and higher order aberrations (coma, spherical aberration, etc.. We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.

  8. Fundamentals and techniques of nonimaging optics for solar energy concentration. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Winston, R.

    1980-05-20

    Nonimaging optics is a new discipline with techniques, formalism and objectives quite distinct from the traditional methods of focusing optics. These new systems achieve or closely approach the maximum concentration permitted by the Second Law of Thermodynamics for a given angular acceptance and are often called ideal. Application of these new principles to solar energy over the past seven years has led to the invention of a new class of solar concentrators, the most well known version of which is the Compound Parabolic Concentrator or CPC. A new formalism for analyzing nonimaging systems in terms of a quantity called the geometrical vector flux has been developed. This has led not only to a better understanding of the properties of ideal concentrators but to the discovery of several new concentrator designs. One of these new designs referred to as the trumpet concentrator has several advantageous features when used as a secondary concentrator for a point focusing dish concentrator. A new concentrator solution for absorbers which must be separated from the reflector by a gap has been invented. The properties of a variety of new and previously known nonimaging optical configurations have been investigated: for example, Compound Elliptical Concentrators (CEC's) as secondary concentrators and asymmetric ideal concentrators. A thermodynamic model which explains quantitatively the enhancement of effective absorptance of gray body receivers through cavity effects has been developed. The classic method of Liu and Jordan, which allows one to predict the diffuse sunlight levels through correlation with the total and direct fraction was revised and updated and applied to predict the performance of nonimaging solar collectors. The conceptual design for an optimized solar collector which integrates the techniques of nonimaging concentration with evacuated tube collector technology was carried out.

  9. [Rapid measurement of trace mercury in aqueous solutions with optical-electrical dual pulse LIBS technique].

    Science.gov (United States)

    Zhang, Qian; Xiong, Wei; Chen, Yu-Qi; Li, Run-Hua

    2011-02-01

    A wood slice was used as absorber to transfer liquid sample to solid sample in order to solve the problems existing in directly analyzing aqueous solutions with laser-induced breakdown spectroscopy (LIBS). An optical-electrical dual pulse LIBS (OEDP-LIBS) technique was first used to enhance atomic emission of mercury in laser-induced plasma. The calibration curves of mercury were obtained by typical single pulse LIBS and OEDP-LIBS techniques. The limit of detection (LOD) of mercury in these two techniques reaches 2.4 and 0.3 mg x L(-1), respectively. Under current experimental conditions, the time-integrated a tomic emission of mercury at 253.65 nm was enhanced 50 times and the LOD of mercury was improved by one order, if comparing OEDP-LIBS to single pulse LIBS. The required time for a whole analysis process is less than 5 minutes. As the atomic emission of mercury decays slowly while increasing the delay time between electrical pulse and laser pulse, increasing the electrical pulse width can further enhance the time integrated intensity of mercury emission and improve the detection sensitivity of mercury by OEDP-LIBS technique.

  10. Two-step technique for posterior optic buttonholing of intraocular lens.

    Science.gov (United States)

    Agarwal, Tushar; Jhanji, Vishal; Singh, Digvijay; Khokhar, Sudarshan

    2014-04-01

    This study aims to describe a two-step surgical technique for placement of a posterior chamber intraocular lens (IOL) in cases with crystalline lens subluxation resulting from non-progressive zonular dialysis. The first stage entails a phacoemulsification with creation of a 4-mm posterior capsular opening using an automated vitrector. The second stage performed 6 weeks later includes an anterior vitrectomy and injection of a foldable three-piece IOL in the sulcus. The haptics of IOL are positioned in the sulcus while the optic is pushed behind the posterior capsular opening therefore "buttonholing" the IOL. Seven eyes of seven patients with posttraumatic zonular dialysis were operated using this technique. Follow-up of all cases revealed a well-centered IOL with good postoperative visual acuity (20/20 to 20/80). Our two-stage surgical technique precludes the insertion of capsular tension ring in cases with non-progressive zonular dialysis. The technique is recommended in the presence of less than or equal to 6 clock hours of zonular dialysis with preexisting posterior capsular tear or herniation of vitreous in the anterior chamber.

  11. Interference-Assisted Techniques for Transmission and Multiple Access in Optical Communications

    Science.gov (United States)

    Guan, Xun

    Optical communications can be in wired or wireless form. Fiber optics communication (FOC) connects transmitters and receivers with optical fiber. Benefiting from its high bandwidth, low cost per volume and stability, it gains a significant market share in long-haul networks, access networks and data centers. Meanwhile, optical wireless communication (OWC) is also emerging as a crucial player in the communication market. In OWC, free-space optical communication (FSO) and visible light communication (VLC) are being studied and commercially deployed extensively. Interference is a common phenomenon in multi-user communication systems. In both FOC and OWC, interference has long been treated as a detrimental effect. However, it could also be beneficial to system applications. The effort of harnessing interference has spurred numerous innovations. Interesting examples are physical-layer network coding (PNC) and non-orthogonal multiple access (NOMA). The first part of this thesis in on the topic of PNC. PNC was firstly proposed in wireless communication to improve the throughput of a two-way relay network (TWRN). As a variation of network coding (NC), PNC turns the common channel interference (CCI) as a natural network coding operation. In this thesis, PNC is introduced into optical communication. Three schemes are proposed in different scenarios. Firstly, PNC is applied to a coherent optical orthogonal frequency division multiplexing (CO-OFDM) system so as to improve the throughput of the multicast network. The optical signal to noise ratio (OSNR) penalty is quite low. Secondly, we investigate the application of PNC in an OFDM passive optical network (OFDM-PON) supporting heterogeneous services. It is found that only minor receiver power penalties are observed to realize PNC-based virtual private networks (VPN), both in the wired service part and the wireless service part in an OFDM-PON with heterogeneous services. Thirdly, we innovate relay-based visible light

  12. Spectroscopic techniques for assessing the possible use of phosphate rock by-products for the removal of trace elements in soils.

    Science.gov (United States)

    Martinez-Sanchez, M. J.; Perez-Sirvent, C.; Garcia-Lorenzo, M. L.; Bech, J.; Hernandez-Cordoba, M.

    2012-04-01

    The production of fertilizers from apatite results in the obtention of considerable amounts of phosphate rock byproducts, representing a serious environmental problem. In addition, soil contamination with heavy metals due to mining or metallurgical activities is a severe environmental problem, increased when soil use is changed to agricultural or urban uses. The aim of this work was to study the possibility of using phosphate rock byproducts for the in situ treatment of soils polluted by heavy metals, allowing to revalorise phosphate rock residues and at the same time, providing a low-cost solution for the contaminated soil. The following methodologies were applied in order to characterise minerals phases present in phosphate rock residues: Wavelength Dispersive X-Ray Spectrometry (WDXRF), Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray Spectrometry (EDS), thermogravimetry (TG) and Fourier Transform Infrared Spectroscopy (FTIR). The results obtained showed that the samples studied had a fine texture, showing average contents of 71%, 24% of sand and 5% for silt, sand and clay, respectivaly. In addition, these materials showed basic-neutral pH values (7.5-9) and a cationic interchange capacity of 20.4 meq/100g. Studied samples showed a 22% of carbonates and a 13% of apatite in their composition and all of them showed 4 bands at 1.100, 1.044, 674 y 576 cm-1, corresponding to P-O vibrations in PO4 groups. OH band vibrations appeared at 3.700-3.550 cm-1, and detected band at 3.400 cm-1 and 633 cm-1 could correspond to occluded water. On the other hand, detected bands at 1.460-1.430, 874 cm-1 suggested the presence of CaCO3 and carbonates in the apatite. After sample characterization, the performance of these residues to adsorb trace element ions (Cd+2 and Pb+2) from acidic aqueous solutions (simulating acidic mine drainage) was studied. The use of spectroscopic techniques after mixing soils and phosphate rock products demonstrate that these residues could be

  13. Bioluminescence : the potential of a non-invasive bio-optical imaging technique and improvement of animal research

    NARCIS (Netherlands)

    Hesselink, J. W.; van Dam, G. M.

    2007-01-01

    Bioluminescence is an optical imaging technique that exploits the emission of photons at specific wavelengths based on energy-dependent reactions catalysed by luciferases. The technique makes it possible to monitor measure, and track biological processes in living animals. A short review is

  14. A Novel Noise Free Transmission Technique for Designing 100Gb/s Future Generation Optical Communication System

    DEFF Research Database (Denmark)

    Das, Bhagwan; Abdullah, M.F.L.; Pandey, Bishwajeet

    2017-01-01

    Differential Phase Shift Keying (DPSK) techniques are widely used in designing the high-speed communication systems. However, these techniques still need improvement for long haul communication system design. In this paper, high-speed optical signal transmission and reception system is achieved f...

  15. Developing new optical imaging techniques for single particle and molecule tracking in live cells

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Wei [Iowa State Univ., Ames, IA (United States)

    2010-01-01

    Differential interference contrast (DIC) microscopy is a far-field as well as wide-field optical imaging technique. Since it is non-invasive and requires no sample staining, DIC microscopy is suitable for tracking the motion of target molecules in live cells without interfering their functions. In addition, high numerical aperture objectives and condensers can be used in DIC microscopy. The depth of focus of DIC is shallow, which gives DIC much better optical sectioning ability than those of phase contrast and dark field microscopies. In this work, DIC was utilized to study dynamic biological processes including endocytosis and intracellular transport in live cells. The suitability of DIC microscopy for single particle tracking in live cells was first demonstrated by using DIC to monitor the entire endocytosis process of one mesoporous silica nanoparticle (MSN) into a live mammalian cell. By taking advantage of the optical sectioning ability of DIC, we recorded the depth profile of the MSN during the endocytosis process. The shape change around the nanoparticle due to the formation of a vesicle was also captured. DIC microscopy was further modified that the sample can be illuminated and imaged at two wavelengths simultaneously. By using the new technique, noble metal nanoparticles with different shapes and sizes were selectively imaged. Among all the examined metal nanoparticles, gold nanoparticles in rod shapes were found to be especially useful. Due to their anisotropic optical properties, gold nanorods showed as diffraction-limited spots with disproportionate bright and dark parts that are strongly dependent on their orientation in the 3D space. Gold nanorods were developed as orientation nanoprobes and were successfully used to report the self-rotation of gliding microtubules on kinesin coated substrates. Gold nanorods were further used to study the rotational motions of cargoes during the endocytosis and intracellular transport processes in live mammalian

  16. The development of optical microscopy techniques for the advancement of single-particle studies

    Science.gov (United States)

    Marchuk, Kyle

    Single particle orientation and rotational tracking (SPORT) has recently become a powerful optical microscopy tool that can expose many molecular motions. Unfortunately, there is not yet a single microscopy technique that can decipher all particle motions in all environmental conditions, thus there are limitations to current technologies. Within, the two powerful microscopy tools of total internal reflection and interferometry are advanced to determine the position, orientation, and optical properties of metallic nanoparticles in a variety of environments. Total internal reflection is an optical phenomenon that has been applied to microscopy to produce either fluorescent or scattered light. The non-invasive far-field imaging technique is coupled with a near-field illumination scheme that allows for better axial resolution than confocal microscopy and epi-fluorescence microscopy. By controlling the incident illumination angle using total internal reflection fluorescence (TIRF) microscopy, a new type of imaging probe called "non-blinking" quantum dots (NBQDs) were super-localized in the axial direction to sub-10-nm precision. These particles were also used to study the rotational motion of microtubules being propelled by the motor protein kinesin across the substrate surface. The same instrument was modified to function under total internal reflection scattering (TIRS) microscopy to study metallic anisotropic nanoparticles and their dynamic interactions with synthetic lipid bilayers. Utilizing two illumination lasers with opposite polarization directions at wavelengths corresponding to the short and long axis surface plasmon resonance (SPR) of the nanoparticles, both the in-plane and out-of-plane movements of many particles could be tracked simultaneously. When combined with Gaussian point spread function (PSF) fitting for particle super-localization, the binding status and rotational movement could be resolved without degeneracy. TIRS microscopy was also used to

  17. The development of optical microscopy techniques for the advancement of single-particle studies

    Energy Technology Data Exchange (ETDEWEB)

    Marchuk, Kyle [Iowa State Univ., Ames, IA (United States)

    2013-05-15

    Single particle orientation and rotational tracking (SPORT) has recently become a powerful optical microscopy tool that can expose many molecular motions. Unfortunately, there is not yet a single microscopy technique that can decipher all particle motions in all environmental conditions, thus there are limitations to current technologies. Within, the two powerful microscopy tools of total internal reflection and interferometry are advanced to determine the position, orientation, and optical properties of metallic nanoparticles in a variety of environments. Total internal reflection is an optical phenomenon that has been applied to microscopy to produce either fluorescent or scattered light. The non-invasive far-field imaging technique is coupled with a near-field illumination scheme that allows for better axial resolution than confocal microscopy and epi-fluorescence microscopy. By controlling the incident illumination angle using total internal reflection fluorescence (TIRF) microscopy, a new type of imaging probe called “non-blinking” quantum dots (NBQDs) were super-localized in the axial direction to sub-10-nm precision. These particles were also used to study the rotational motion of microtubules being propelled by the motor protein kinesin across the substrate surface. The same instrument was modified to function under total internal reflection scattering (TIRS) microscopy to study metallic anisotropic nanoparticles and their dynamic interactions with synthetic lipid bilayers. Utilizing two illumination lasers with opposite polarization directions at wavelengths corresponding to the short and long axis surface plasmon resonance (SPR) of the nanoparticles, both the in-plane and out-of-plane movements of many particles could be tracked simultaneously. When combined with Gaussian point spread function (PSF) fitting for particle super-localization, the binding status and rotational movement could be resolved without degeneracy. TIRS microscopy was also used to

  18. Non-interferometric determination of optical anisotropy in highly-oriented fibres using transport intensity equation technique

    Science.gov (United States)

    Sokkar, T. Z. N.; El-Farahaty, K. A.; El-Bakary, M. A.; Raslan, M. I.; Omar, E. Z.; Hamza, A. A.

    2018-03-01

    The optical setup of the transport intensity equation (TIE) technique is developed to be valid for measuring the optical properties of the highly-oriented anisotropic fibres. This development is based on the microstructure models of the highly-oriented anisotropic fibres and the principle of anisotropy. We provide the setup of TIE technique with polarizer which is controlled via stepper motor. This developed technique is used to investigate the refractive indices in the parallel and perpendicular polarization directions of light for the highly-oriented poly (ethylene terephthalate) (PET) fibres and hence its birefringence. The obtained results through the developed TIE technique for PET fibre are compared with that determined experimentally using the Mach-Zehnder interferometer under the same conditions. The comparison shows a good agreement between the obtained results from the developed technique and that obtained from the Mach-Zehnder interferometer technique.

  19. Normal-incidence spectroscopic ellipsometry for critical dimension monitoring

    International Nuclear Information System (INIS)

    Huang, Hsu-Ting; Kong, Wei; Terry, Fred Lewis

    2001-01-01

    In this letter, we show that normal-incidence spectroscopic ellipsometry can be used for high-accuracy topography measurements on surface relief gratings. We present both experimental and theoretical results which show that spectroscopic ellipsometry or reflectance-difference spectroscopy at near-normal incidence coupled with vector diffraction theory for data analysis is capable of high-accuracy critical dimension (CD), feature height, and sidewall angle measurements in the extreme submicron regime. Quantitative comparisons of optical and cross-sectional scanning electron microscopy (SEM) topography measurements from a number of 350 nm line/space reactive-ion-etched Si gratings demonstrate the strong potential for in situ etching monitoring. This technique can be used for both ex situ and in situ applications and has the potential to replace the use of CD-SEM measurements in some applications. [copyright] 2001 American Institute of Physics

  20. Radiation hardening techniques for rare-earth based optical fibers and amplifiers

    International Nuclear Information System (INIS)

    Girard, Sylvain; Marcandella, Claude; Vivona, Marilena; Prudenzano, Luciano Mescia F.; Laurent, Arnaud; Robin, Thierry; Cadier, Benoit; Pinsard, Emmanuel; Ouerdane, Youcef; Boukenter, Aziz; Cannas, Marco; Boscaino, Roberto

    2012-01-01

    Er/Yb doped fibers and amplifiers have been shown to be very radiation sensitive, limiting their integration in space. We present an approach including successive hardening techniques to enhance their radiation tolerance. The efficiency of our approach is demonstrated by comparing the radiation responses of optical amplifiers made with same lengths of different rare-earth doped fibers and exposed to gamma-rays. Previous studies indicated that such amplifiers suffered significant degradation for doses exceeding 10 krad. Applying our techniques significantly enhances the amplifier radiation resistance, resulting in a very limited degradation up to 50 krad. Our optimization techniques concern the fiber composition, some possible pre-treatments and the interest of simulation tools used to harden by design the amplifiers. We showed that adding cerium inside the fiber phospho-silicate-based core strongly decreases the fiber radiation sensitivity compared to the standard fiber. For both fibers, a pre-treatment with hydrogen permits to enhance again the fiber resistance. Furthermore, simulations tools can also be used to improve the tolerance of the fiber amplifier by helping identifying the best amplifier configuration for operation in the radiative environment. (authors)

  1. Refractive error assessment: influence of different optical elements and current limits of biometric techniques.

    Science.gov (United States)

    Ribeiro, Filomena; Castanheira-Dinis, Antonio; Dias, Joao Mendanha

    2013-03-01

    To identify and quantify sources of error on refractive assessment using exact ray tracing. The Liou-Brennan eye model was used as a starting point and its parameters were varied individually within a physiological range. The contribution of each parameter to refractive error was assessed using linear regression curve fits and Gaussian error propagation analysis. A MonteCarlo analysis quantified the limits of refractive assessment given by current biometric measurements. Vitreous and aqueous refractive indices are the elements that influence refractive error the most, with a 1% change of each parameter contributing to a refractive error variation of +1.60 and -1.30 diopters (D), respectively. In the phakic eye, axial length measurements taken by ultrasound (vitreous chamber depth, lens thickness, and anterior chamber depth [ACD]) were the most sensitive to biometric errors, with a contribution to the refractive error of 62.7%, 14.2%, and 10.7%, respectively. In the pseudophakic eye, vitreous chamber depth showed the highest contribution at 53.7%, followed by postoperative ACD at 35.7%. When optic measurements were considered, postoperative ACD was the most important contributor, followed by anterior corneal surface and its asphericity. A MonteCarlo simulation showed that current limits of refractive assessment are 0.26 and 0.28 D for the phakic and pseudophakic eye, respectively. The most relevant optical elements either do not have available measurement instruments or the existing instruments still need to improve their accuracy. Ray tracing can be used as an optical assessment technique, and may be the correct path for future personalized refractive assessment. Copyright 2013, SLACK Incorporated.

  2. Phase-only optical encryption based on the zeroth-order phase-contrast technique

    Science.gov (United States)

    Pizolato, José Carlos; Neto, Luiz Gonçalves

    2009-09-01

    A phase-only encryption/decryption scheme with the readout based on the zeroth-order phase-contrast technique (ZOPCT), without the use of a phase-changing plate on the Fourier plane of an optical system based on the 4f optical correlator, is proposed. The encryption of a gray-level image is achieved by multiplying the phase distribution obtained directly from the gray-level image by a random phase distribution. The robustness of the encoding is assured by the nonlinearity intrinsic to the proposed phase-contrast method and the random phase distribution used in the encryption process. The experimental system has been implemented with liquid-crystal spatial modulators to generate phase-encrypted masks and a decrypting key. The advantage of this method is the easy scheme to recover the gray-level information from the decrypted phase-only mask applying the ZOPCT. An analysis of this decryption method was performed against brute force attacks.

  3. Frequency Adaptive Control Technique for Periodic Runout and Wobble Cancellation in Optical Disk Drives

    Directory of Open Access Journals (Sweden)

    Yee-Pien Yang

    2006-10-01

    Full Text Available Periodic disturbance occurs in various applications on the control of the rotational mechanical systems. For optical disk drives, the spirally shaped tracks are usually not perfectly circular and the assembly of the disk and spindle motor is unavoidably eccentric. The resulting periodic disturbance is, therefore, synchronous with the disk rotation, and becomes particularly noticeable for the track following and focusing servo system. This paper applies a novel adaptive controller, namely Frequency Adaptive Control Technique (FACT, for rejecting the periodic runout and wobble effects in the optical disk drive with dual actuators. The control objective is to attenuate adaptively the specific frequency contents of periodic disturbances without amplifying its rest harmonics. FACT is implemented in a plug-in manner and provides a suitable framework for periodic disturbance rejection in the cases where the fundamental frequencies of the disturbance are alterable. It is shown that the convergence property of parameters in the proposed adaptive algorithm is exponentially stable. It is applicable to both the spindle modes of constant linear velocity (CLV and constant angular velocity (CAV for various operation speeds. The experiments showed that the proposed FACT has successful improvement on the tracking and focusing performance of the CD-ROM, and is extended to various compact disk drives.

  4. Optical and Electrical Properties of Tin-Doped Cadmium Oxide Films Prepared by Electron Beam Technique

    Science.gov (United States)

    Ali, H. M.; Mohamed, H. A.; Wakkad, M. M.; Hasaneen, M. F.

    2009-04-01

    Tin-doped cadmium oxide films were deposited by electron beam evaporation technique. The structural, optical and electrical properties of the films were characterized. The X-ray diffraction (XRD) study reveals that the films are polycrystalline in nature. As composition and structure change due to the dopant ratio and annealing temperature, the carrier concentration was varied around 1020 cm-3, and the mobility increased from less than 10 to 45 cm2 V-1 s-1. A transmittance value of ˜83% and a resistivity value of 4.4 ×10-4 Ω cm were achieved for (CdO)0.88(SnO2)0.12 film annealed at 350 °C for 15 min., whereas the maximum value of transmittance ˜93% and a resistivity value of 2.4 ×10-3 Ω cm were obtained at 350 °C for 30 min. The films exhibited direct band-to-band transitions, which corresponded to optical band gaps of 3.1-3.3 eV.

  5. Optical Coherence Tomography Angiography: Employing a Novel Technique for Investigation in Vogt-Koyanagi-Harada Disease.

    Science.gov (United States)

    Giannakouras, Panagiotis; Andreanos, Konstantinos; Giavi, Barbara; Diagourtas, Andreas

    2017-01-01

    To report a case of Vogt-Koyanagi-Harada (VKH) disease and describe the imaging findings by means of optical coherence tomography angiography (OCTA). Medical and ophthalmological history, ophthalmological examination, laboratory evaluation, B-scan ultrasonography, fluorescein and indocyanine angiography, and optical coherence tomography (OCT) were performed at baseline, as well as OCTA. A 50-year-old healthy female presented with decreased vision in both eyes. A Topcon DRI OCT Triton Plus swept source OCT system was used to visualize and evaluate the retinal and choroidal vascular plexus. Patchy and confluent dark areas in the superficial and deep retinal capillary plexus and choriocapillaris corresponded to areas of hypoperfusion, analyzed as areas of ischemia. VKH disease is characterized by ocular, neurological, and integumentary findings in its complete form. We present a case of incomplete disease in a 50-year-old female evaluated by means of OCTA which is a novel technique that provides depth-resolved images of the retina and choroidal microvasculature without dye injection that allows better visualization and detailed evaluation of the retinal and choroidal vascular plexus.

  6. Optical Coherence Tomography Angiography: Employing a Novel Technique for Investigation in Vogt-Koyanagi-Harada Disease

    Directory of Open Access Journals (Sweden)

    Panagiotis Giannakouras

    2017-07-01

    Full Text Available Purpose: To report a case of Vogt-Koyanagi-Harada (VKH disease and describe the imaging findings by means of optical coherence tomography angiography (OCTA. Methods: Medical and ophthalmological history, ophthalmological examination, laboratory evaluation, B-scan ultrasonography, fluorescein and indocyanine angiography, and optical coherence tomography (OCT were performed at baseline, as well as OCTA. Results: A 50-year-old healthy female presented with decreased vision in both eyes. A Topcon DRI OCT Triton Plus swept source OCT system was used to visualize and evaluate the retinal and choroidal vascular plexus. Patchy and confluent dark areas in the superficial and deep retinal capillary plexus and choriocapillaris corresponded to areas of hypoperfusion, analyzed as areas of ischemia. Conclusions and Importance: VKH disease is characterized by ocular, neurological, and integumentary findings in its complete form. We present a case of incomplete disease in a 50-year-old female evaluated by means of OCTA which is a novel technique that provides depth-resolved images of the retina and choroidal microvasculature without dye injection that allows better visualization and detailed evaluation of the retinal and choroidal vascular plexus.

  7. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  8. A novel technique for die-level post-processing of released optical MEMS

    International Nuclear Information System (INIS)

    Elsayed, Mohannad Y; Beaulieu, Philippe-Olivier; Briere, Jonathan; Ménard, Michaël; Nabki, Frederic

    2016-01-01

    This work presents a novel die-level post-processing technique for dies including released movable structures. The procedure was applied to microelectromechanical systems (MEMS) chips that were fabricated in a commercial process, SOIMUMPs from MEMSCAP. It allows the performance of a clean DRIE etch of sidewalls on the diced chips enabling the optical testing of the pre-released MEMS mirrors through the chip edges. The etched patterns are defined by photolithography using photoresist spray coating. The photoresist thickness is tuned to create photoresist bridges over the pre-released gaps, protecting the released structures during subsequent wet processing steps. Then, the chips are subject to a sequence of wet and dry etching steps prior to dry photoresist removal in O 2 plasma. Processed micromirrors were tested and found to rotate similarly to devices without processing, demonstrating that the post-processing procedure does not affect the mechanical performance of the devices significantly. (technical note)

  9. Hysteresis compensation technique applied to polymer optical fiber curvature sensor for lower limb exoskeletons

    Science.gov (United States)

    Gomes Leal-Junior, Arnaldo; Frizera-Neto, Anselmo; José Pontes, Maria; Rodrigues Botelho, Thomaz

    2017-12-01

    Polymer optical fiber (POF) curvature sensors present some advantages over conventional techniques for angle measurements, such as their light weight, compactness and immunity to electromagnetic fields. However, high hysteresis can occur in POF curvature sensors due to the polymer viscoelastic response. In order to overcome this limitation, this paper shows how the hysteresis sensor can be compensated by a calibration equation relating the measured output signal to the sensor’s angular velocity. The proposed method is validated using an exoskeleton with an active joint on the knee for flexion and extension rehabilitation exercises. The results show a decrease in sensor hysteresis and a decrease by more than two times in the error between the POF sensor and the potentiometer, which is employed for the angle measurement of the exoskeleton knee joint.

  10. Dipole field measurement technique utilizing the Faraday rotation effect in polarization preserving optical fibers

    International Nuclear Information System (INIS)

    Haddock, C.; Tong, M.Y.M.

    1989-10-01

    TRIUMF is presently in the project definition stage of its proposed KAON factory. The facility will require approximately 300 dipole magnets. The rapid measurement of representative parameters of these magnets, in particular effective length, is one of the challenges to be met. As well as the commissioning of a.c magnetic field measurement systems based on established techniques a project is underway to investigate an alternative method utilizing the Faraday Rotation effect in polarization preserving optical fibers. It is shown that a fiber equivalent to a Faraday cell can be constructed by winding a fiber in a such a way that the induced beat length L p is equal to (2n+1) times the bending circumference, with n integer. Background to the subject and preliminary results of the measurements are reported in this paper

  11. The Diagnosis of Plasma Parameters in Surface Alloying Technique by Optical Emission Spectrometry

    International Nuclear Information System (INIS)

    Fu Yabo; Zhang Yuefei; Chen Qiang; Zhang Guangqiu; Gao Yuan; Wang Jianzhong; Kui Xiaoyun

    2006-01-01

    Electron density (Ne) in a glow discharge plasma for the surface alloying technique is diagnosed by optical emission spectrometry (OES). With CH 4 as the feeding gas, Ne is obtained by comparing the Hβ spectrum according to the Stark broadening effect. It is noticed that Ne varies with the working pressures (30 Pa to 70 Pa) and cathode voltages (500 V to 1000 V), respectively. Due to an abnormal glow discharge, Ne is between 1.71x10 15 /cm 3 to 6.64x10 15 /cm 3 and increases rapidly with working gas pressures and cathode voltages. The results show that OES is a useful method to measure the plasma parameters in a surface alloying glow discharge plasma

  12. Electro-optical techniques for the investigation of photoplethysmographic signals in human abdominal organs

    International Nuclear Information System (INIS)

    Kyriacou, P A; Crerar-Gilber, A; Langford, R M; Jones, D P

    2006-01-01

    There is a need for reliable continuous monitoring of abdominal organ oxygen saturation (SpO 2 ). Splanchnic ischaemia may ultimately lead to cellular hypoxia and necrosis and may well contribute to the development of multiple organ failures and increased mortality. A new reflectance electro-optical photoplethysmographic (PPG) probe and signal processing system were developed. PPG signals from abdominal organs (bowel, liver, and kidney) and the finger were obtained from 12 anaesthetised patients. The amplitudes of the abdominal organ PPGs were, on average, approximately the same as those obtained simultaneously from the finger. These observations suggest that pulse oximetry may be a valid monitoring technique for abdominal organs such as the bowel liver and kidney

  13. Measurements of nonlinear optical properties of PVDF/ZnO using Z-scan technique

    Energy Technology Data Exchange (ETDEWEB)

    Shanshool, Haider Mohammed, E-mail: haidshan62@gmail.com [Ministry of Science and Technology, Baghdad (Iraq); Yahaya, Muhammad [School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Selangor (Malaysia); Yunus, Wan Mahmood Mat [Department of Physics, Faculty of Science, University Putra Malaysia, Serdang (Malaysia); Abdullah, Ibtisam Yahya [Department of Physics, College of Science, University of Mosul, Mosul (Iraq)

    2015-10-15

    The nonlinear optical properties of ZnO nanoparticles dispersed in poly (vinylidene fluoride) (PVDF) polymer are investigated. PVDF/ZnO nanocomposites were prepared by mixing different concentrations of ZnO nanoparticles, as the filler, with PVDF, as the polymer matrix, using casting method. Acetone was used as a solvent for the polymer. FTIR spectra of the samples were analyzed thus confirming the formation of α and β phases. The absorbance spectra of the samples were obtained, thereby showing high absorption in the UV region. The linear absorption coefficient was calculated. The single-beam Z-scan technique was used to measure the nonlinear refractive index and the nonlinear absorption coefficient of the PVDF/ZnO nanocomposite samples. We observed that the nonlinear refractive index is in the order of 10{sup -13} cm{sup 2}/W with the negative sign, whereas the nonlinear absorption coefficient is in the order of 10{sup -8} cm/W. (author)

  14. Structural and optical properties of WTe2 single crystals synthesized by DVT technique

    Science.gov (United States)

    Dixit, Vijay; Vyas, Chirag; Pathak, V. M.; Soalanki, G. K.; Patel, K. D.

    2018-05-01

    Layered transition metal di-chalcogenide (LTMDCs) crystals have attracted much attention due to their potential in optoelectronic device applications recently due to realization of their monolayer based structures. In the present investigation we report growth of WTe2 single crystals by direct vapor transport (DVT) technique. These crystals are then characterized by energy dispersive analysis of x-rays (EDAX) to study stoichiometric composition after growth. The structural properties are studied by x-ray diffraction (XRD) and selected area electron diffraction (SAED) is used to confirm orthorhombic structure of grown WTe2 crystal. Surface morphological properties of the crystals are also studied by scanning electron microscope (SEM). The optical properties of the grown crystals are studied by UV-Visible spectroscopy which gives direct band gap of 1.44 eV for grown WTe2 single crystals.

  15. Monitoring programmed cell death of living plant tissues in microfluidics using electrochemical and optical techniques

    DEFF Research Database (Denmark)

    Mark, Christina; Zor, Kinga; Heiskanen, Arto

    such as redox activity, O2 and H2O2 concentration, pH, cell viability and release of target enzymes such as α-amylase. We have optimised an intracellular, whole-cell redox activity assay[3] that detects changes in redox activity in barley aleurone layer during PCD. The assay uses a double mediator......This project focuses on developing and applying a tissue culture system with electrochemical and optical detection techniques for tissue culture of barley aleurone layer to increase understanding of the underlying mechanisms of programmed cell death (PCD) in plants. The major advantage......-system to electrochemically measure redox activity via changes in the NADP:NADPH ratio. Experiments show that redox activity changes depend on phytohormone activation or inactivation of aleurone layer metabolism and subsequent PCD. We have also successfully detected PCD induced by phytohormones in barley aleurone layer using...

  16. Novel all-optical dispersion monitoring technique for ultra-high-speed WDM networks

    Energy Technology Data Exchange (ETDEWEB)

    Cui Sheng; Li Li; Liu Deming, E-mail: cuisheng@mail.hust.edu.cn [Wuhan National Laboratory for Optoelectronics, No.1037, Luoyu Road, Wuhan, Hubei, 430074 (China)

    2011-02-01

    This paper represents a novel all-optical dispersion monitoring technique based on fiber parametric amplifiers (FOPAs). The monitoring method is truly bit-rate transparent because it is enabled by the exponential power transfer function (PTF) provided by the FOPA gain. The slope of the PTF is increased from 2 to 3 by choosing appropriate phase-matching conditions. Due to the steeper PTF the monitoring sensitivity is greatly improved compared to the other PTF-based methods proposed before. The PTF obtained by numerical simulations agrees very well with the experimental results. Numerical simulations are then used to demonstrate that our method can be used to monitor signals in various modulation formats.

  17. Enhancement of Lithium Niobate nanophotonic structures via spin-coating technique for optical waveguides application

    Directory of Open Access Journals (Sweden)

    Fakhri Makram A.

    2017-01-01

    Full Text Available This work is dedicated to investigation of temperature effects in Lithium Niobate (LiNbO3 nanostructures. The LiNbO3 nanostructures were deposited on glass substrate by spin-coating technique. LiNbO3 was set down at 3000 rpm for 30 sec and annealed from 100 to 600 °C. The structures were characterized and analyzed by scanning electron microscopy (SEM and ultra-violet visible (UV-vis spectrophotometer. The measured results have showed that by increasing annealing temperatures, the structures start to be more crystallized and be more homogenized until the optimum arrangement was achieved. Once this was accomplished, it's applicable for optical waveguides development. Eventually, it starts to be less crystallization and non-homogeneous. Energy gap was recorded to be at average value of 3.9 eV.

  18. Studies on third-order optical nonlinearity and power limiting of conducting polymers using the z-scan technique for nonlinear optical applications

    Science.gov (United States)

    Pramodini, S.; Sudhakar, Y. N.; SelvaKumar, M.; Poornesh, P.

    2014-04-01

    We present the synthesis and characterization of third-order optical nonlinearity and optical limiting of the conducting polymers poly (aniline-co-o-anisidine) and poly (aniline-co-pyrrole). Nonlinear optical studies were carried out by employing the z-scan technique using a He-Ne laser operating in continuous wave mode at 633 nm. The copolymers exhibited a reverse saturable absorption process and self-defocusing properties under the experimental conditions. The estimated values of βeff, n2 and χ(3) were found to be of the order of 10-2 cm W-1, 10-5 esu and 10-7 esu respectively. Self-diffraction rings were observed due to refractive index change when exposed to the laser beam. The copolymers possess a lower limiting threshold and clamping level, which is essential to a great extent for power limiting devices. Therefore, copolymers of aniline emerge as a potential candidate for nonlinear optical device applications.

  19. White matter tract-specific quantitative analysis in multiple sclerosis: Comparison of optic radiation reconstruction techniques.

    Directory of Open Access Journals (Sweden)

    Chenyu Wang

    Full Text Available The posterior visual pathway is commonly affected by multiple sclerosis (MS pathology that results in measurable clinical and electrophysiological impairment. Due to its highly structured retinotopic mapping, the visual pathway represents an ideal substrate for investigating patho-mechanisms in MS. Therefore, a reliable and robust imaging segmentation method for in-vivo delineation of the optic radiations (OR is needed. However, diffusion-based tractography approaches, which are typically used for OR segmentation are confounded by the presence of focal white matter lesions. Current solutions require complex acquisition paradigms and demand expert image analysis, limiting application in both clinical trials and clinical practice. In the current study, using data acquired in a clinical setting on a 3T scanner, we optimised and compared two approaches for optic radiation (OR reconstruction: individual probabilistic tractography-based and template-based methods. OR segmentation results were applied to subjects with MS and volumetric and diffusivity parameters were compared between OR segmentation techniques. Despite differences in reconstructed OR volumes, both OR lesion volume and OR diffusivity measurements in MS subjects were highly comparable using optimised probabilistic tractography-based, and template-based, methods. The choice of OR reconstruction technique should be determined primarily by the research question and the nature of the available dataset. Template-based approaches are particularly suited to the semi-automated analysis of large image datasets and have utility even in the absence of dMRI acquisitions. Individual tractography methods, while more complex than template based OR reconstruction, permit measurement of diffusivity changes along fibre bundles that are affected by specific MS lesions or other focal pathologies.

  20. Comparative study on structural and optical properties of CdS films fabricated by three different low-cost techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ravichandran, K. [P.G. and Research Department of Physics, AVVM. Sri Pushpam College, Poondi, Thanjavur District, Tamil Nadu 613503 (India)], E-mail: kkr1365@yahoo.com; Philominathan, P. [P.G. and Research Department of Physics, AVVM. Sri Pushpam College, Poondi, Thanjavur District, Tamil Nadu 613503 (India)

    2009-03-15

    Highly crystalline and transparent cadmium sulphide films were fabricated at relatively low temperature by employing an inexpensive, simplified spray technique using perfume atomizer (generally used for cosmetics). The structural, surface morphological and optical properties of the films were studied and compared with that prepared by conventional spray pyrolysis using air as carrier gas and chemical bath deposition. The films deposited by the simplified spray have preferred orientation along (1 0 1) plane. The lattice parameters were calculated as a = 4.138 A and c = 6.718 A which are well agreed with that obtained from the other two techniques and also with the standard data. The optical transmittance in the visible range and the optical band gap were found as 85% and 2.43 eV, respectively. The structural and optical properties of the films fabricated by the simplified spray are found to be desirable for opto-electronic applications.

  1. Dynamic View on Nanostructures: A Technique for Time Resolved Optical Luminescence Using Synchrotron Light Pulses at SRC, APS, and CLS

    International Nuclear Information System (INIS)

    Heigl, F.; Jurgensen, A.; Zhou, X.-T.; Lam, S.; Murphy, M.; Ko, J.Y.P.; Sham, T.K.; Rosenberg, R.A.; Gordon, R.; Brewe, D.; Regier, T.; Armelao, L.

    2007-01-01

    We present an experimental technique using the time structure of synchrotron radiation to study time resolved X-ray excited optical luminescence. In particular we are taking advantage of the bunched distribution of electrons in a synchrotron storage ring, giving short x-ray pulses (10-10 2 picoseconds) which are separated by non-radiating gaps on the nano- to tens of nanosecond scale - sufficiently wide to study a broad range of optical decay channels observed in advanced nanostructured materials.

  2. Optical absorption and spectroscopic properties of thulium doped (TeO{sub 2})(Nb{sub 2}O{sub 5})(TiO{sub 2}) glasses

    Energy Technology Data Exchange (ETDEWEB)

    Kabalci, Idris [Department of Physics Education, Education Faculty, Harran University, Sanliurfa (Turkey); Tay, Turgay [Department of Chemistry, Science Faculty, Anadolu University, Eskisehir (Turkey); Oezen, Goenuel [Department of Physics, Science and Arts Faculty, Istanbul Technical University, Istanbul (Turkey)

    2011-09-15

    A type of thulium doped tellurite based optical glasses was prepared through conventional melt quenching technique. In the experiments, the effect of different Tm{sup 3+} ion concentration and glass composition on optical properties of (TeO{sub 2}){sub (1-x-y)}(Nb{sub 2}O{sub 5}){sub (x)}(TiO{sub 2}){sub (y)} (x=0.05, 0.10, 0.15, and 0.20 mol) glasses have been investigated by using UV-VIS-NIR optical spectrophotometry measurements in a wavelength range 400-2000 nm. Considering absorption measurements for the 1.0mol% Tm{sup 3+} doped of (TeO{sub 2}){sub 0.9}(Nb{sub 2}O{sub 5}){sub 0.05}(TiO{sub 2}){sub 0.05} glass, {sup 1}G{sub 4}, {sup 3}F{sub 2}, {sup 3}F{sub 3}, {sup 3}F{sub 4}, {sup 3}H{sub 5}, and {sup 3}H{sub 4} absorption bands were observed from the {sup 3}H{sub 6} ground level, at 463, 660, 687, 793, 1211 and 1700 nm wavelengths, respectively. Furthermore, spontaneous emission probabilities, and the radiative lifetimes for the 4f-4f transitions of the Tm{sup 3+} ions were calculated. The spectral intensities were determined in terms of Judd-Ofelt parameters ({omega}{sub 2}, {omega}{sub 4}, {omega}{sub 6}). Luminescence analysis was realized for the different Tm{sup 3+} ion concentration (0.002, 0.005 and 0.01mol) at room temperature. The luminescence band intensity of the {sup 3}F{sub 4}{yields}{sup 3}H{sub 4} transition was measured as a function of Tm{sup 3+} ion concentration (0.002, 0.005 and 0.01mol). Furthermore, luminescence data of the thulium doped glass samples were used to determine the compositional dependence of the emission cross sections at 1470 nm (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. Reducing BER of spectral-amplitude coding optical code-division multiple-access systems by single photodiode detection technique

    Science.gov (United States)

    Al-Khafaji, H. M. R.; Aljunid, S. A.; Amphawan, A.; Fadhil, H. A.; Safar, A. M.

    2013-03-01

    In this paper, we present a single photodiode detection (SPD) technique for spectral-amplitude coding optical code-division multiple-access (SAC-OCDMA) systems. The proposed technique eliminates both phase-induced intensity noise (PIIN) and multiple-access interference (MAI) in the optical domain. Analytical results show that for 35 simultaneous users transmitting at data rate of 622 Mbps, the bit-error rate (BER) = 1.4x10^-28 for SPD technique is much better compared to 9.3x10^-6 and 9.6x10^-3 for the modified-AND as well as the AND detection techniques, respectively. Moreover, we verified the improved performance afforded by the proposed technique using data transmission simulations.

  4. Using a novel spectroscopic reflectometer to optimize a radiation-hardened submicron silicon-on-sapphire CMOS process; Utilisation d'une nouvelle reflectometrie spectroscopique pour optimiser un procede de fabrication CMOS/SOS durci aux radiations

    Energy Technology Data Exchange (ETDEWEB)

    Do, N.T.; Zawaideh, E.; Vu, T.Q.; Warren, G.; Mead, D. [Raytheon Systems company, Microelectronics Div., Newport Beach, California (United States); Li, G.P.; Tsai, C.S. [California Univ., School of Engineering, Newport Beach, CA (United States)

    1999-07-01

    A radiation-hardened sub-micron silicon-on-sapphire CMOS process is monitored and optimized using a novel optical technique based on spectroscopic reflectometry. Quantitative measurements of the crystal quality, surface roughness, and device radiation hardness show excellent correlation between this technique and the Atomic Force Microscopy. (authors)

  5. Bilateral optic neuritis in a child diagnosed with Gd-enhanced MR imaging using fat-suppression technique

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, K.; Ogawa, R.; Furusawa, T.; Sakai, K. [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Ito, J.; Tokiguchi, S. [Dept. of Radiology, Niigata University School of Dentistry (Japan); Takagi, M. [Dept. of Ophthalmology, Niigata Univ. School of Medicine (Japan)

    1999-05-01

    A 4-year-old boy developed bilateral optic neuritis. Although precise neuro-ophthalmological evaluation was difficult, the diagnosis was made with gadolinium-enhanced MR imaging using fat-suppression technique in the initial stage of the disease. Enhancement and enlargement of the intraorbital and intracanalicular optic nerve were demonstrated bilaterally as well as protrusion of the optic nerve head. The disease responded dramatically to intravenous steroid therapy. The etiologies in children usually differ from those in adolescent and adult patients. (orig.) With 1 fig., 13 refs.

  6. A new optical method improves fluorescence guided diagnosis of bladder tumor in the outpatient department and reveals significant photo bleaching problems in established inpatients PDD techniques

    Science.gov (United States)

    Lindvold, Lars R.; Hermann, Gregers G.

    2013-03-01

    Photo dynamic diagnosis (PDD) is a convenient and well-documented procedure for diagnosis of bladder cancer and tumours using endoscopic techniques. At present, this procedure is available only for routine use in an operating room (OR) and often with substantial photobleaching effects of the photosensitizer. We present a novel optical design of the endoscopic PDD procedure that allows the procedure to be performed in the outpatient department (OPD) and not only in the OR. Thereby, inpatient procedures lasting 1-2 days may be replaced by a few hours lasting procedure in the OPD. Urine blurs the fluorescence during PDD used in the OPD. Urine contains fluorescent metabolites that are excited by blue light giving an opaque green fluorescence confounding the desired red fluorescence (PDD) from the tumour tissue. Measurements from the clinical situation has shown that some systems for PPD based on blue light illumination (PDD mode) and white light illumination used for bladder tumour diagnosis and surgery suffers some inherent disadvantages, i.e., photo bleaching in white light that impairs the possibility for PDD as white light usually is used before the blue light for PDD. Based on spectroscopic observations of urine and the photoactive dye Protoporphyrin IX used in PDD a novel optical system for use with the cystoscope has been devised that solves the problem of green fluorescence from urine. This and the knowledge of photo-bleaching pitfalls in established systems make it possible to perform PDD of bladder tumours in the OPD and to improve PDD in the OR.

  7. [Getting an insight into the brain - new optical clearing techniques and imaging using light-sheet microscope].

    Science.gov (United States)

    Pawłowska, Monika; Legutko, Diana; Stefaniuk, Marzena

    2017-01-01

    One of the biggest challenges in neuroscience is to understand how brain operates. For this, it would be the best to image the whole brain with at least cellular resolution, preserving the three-dimensional structure in order to capture the connections between different areas. Most currently available high-resolution imaging techniques are based on preparing thin brain sections that are next photographed one by one and subsequently bigger structures are reconstructed. These techniques are laborious and create artifacts. Recent optical clearing methods allow to obtain literally transparent brains that can be imaged using light-sheet microscope. The present review summarizes the most popular optical clearing techniques, describing their different mechanisms and comparing advantages and disadvantages of different approaches, and presents the principle of light-sheet microscopy and its use in imaging. Finally, it gives examples of application of optical tissue clearing and light-sheet imaging in neuroscience and beyond it.

  8. Tailoring properties of lossy-mode resonance optical fiber sensors with atomic layer deposition technique

    Science.gov (United States)

    Kosiel, Kamil; Koba, Marcin; Masiewicz, Marcin; Śmietana, Mateusz

    2018-06-01

    The paper shows application of atomic layer deposition (ALD) technique as a tool for tailoring sensorial properties of lossy-mode-resonance (LMR)-based optical fiber sensors. Hafnium dioxide (HfO2), zirconium dioxide (ZrO2), and tantalum oxide (TaxOy), as high-refractive-index dielectrics that are particularly convenient for LMR-sensor fabrication, were deposited by low-temperature (100 °C) ALD ensuring safe conditions for thermally vulnerable fibers. Applicability of HfO2 and ZrO2 overlays, deposited with ALD-related atomic level thickness accuracy for fabrication of LMR-sensors with controlled sensorial properties was presented. Additionally, for the first time according to our best knowledge, the double-layer overlay composed of two different materials - silicon nitride (SixNy) and TaxOy - is presented for the LMR fiber sensors. The thin films of such overlay were deposited by two different techniques - PECVD (the SixNy) and ALD (the TaxOy). Such approach ensures fast overlay fabrication and at the same time facility for resonant wavelength tuning, yielding devices with satisfactory sensorial properties.

  9. Quantitative characterization of steady and time-varying, sooting, laminar diffusion flames using optical techniques

    Science.gov (United States)

    Connelly, Blair C.

    In order to reduce the emission of pollutants such as soot and NO x from combustion systems, a detailed understanding of pollutant formation is required. In addition to environmental concerns, this is important for a fundamental understanding of flame behavior as significant quantities of soot lower local flame temperatures, increase overall flame length and affect the formation of such temperature-dependent species as NOx. This problem is investigated by carrying out coupled computational and experimental studies of steady and time-varying sooting, coflow diffusion flames. Optical diagnostic techniques are a powerful tool for characterizing combustion systems, as they provide a noninvasive method of probing the environment. Laser diagnostic techniques have added advantages, as systems can be probed with high spectral, temporal and spatial resolution, and with species selectivity. Experimental soot volume fractions were determined by using two-dimensional laser-induced incandescence (LII), calibrated with an on-line extinction measurement, and soot pyrometry. Measurements of soot particle size distributions are made using time-resolved LII (TR-LII). Laser-induced fluorescence measurements are made of NO and formaldehyde. These experimental measurements, and others, are compared with computational results in an effort to understand and model soot formation and to examine the coupled relationship of soot and NO x formation.

  10. Study on rapid valid acidity evaluation of apple by fiber optic diffuse reflectance technique

    Science.gov (United States)

    Liu, Yande; Ying, Yibin; Fu, Xiaping; Jiang, Xuesong

    2004-03-01

    Some issues related to nondestructive evaluation of valid acidity in intact apples by means of Fourier transform near infrared (FTNIR) (800-2631nm) method were addressed. A relationship was established between the diffuse reflectance spectra recorded with a bifurcated optic fiber and the valid acidity. The data were analyzed by multivariate calibration analysis such as partial least squares (PLS) analysis and principal component regression (PCR) technique. A total of 120 Fuji apples were tested and 80 of them were used to form a calibration data set. The influence of data preprocessing and different spectra treatments were also investigated. Models based on smoothing spectra were slightly worse than models based on derivative spectra and the best result was obtained when the segment length was 5 and the gap size was 10. Depending on data preprocessing and multivariate calibration technique, the best prediction model had a correlation efficient (0.871), a low RMSEP (0.0677), a low RMSEC (0.056) and a small difference between RMSEP and RMSEC by PLS analysis. The results point out the feasibility of FTNIR spectral analysis to predict the fruit valid acidity non-destructively. The ratio of data standard deviation to the root mean square error of prediction (SDR) is better to be less than 3 in calibration models, however, the results cannot meet the demand of actual application. Therefore, further study is required for better calibration and prediction.

  11. Measurement techniques using ultrashort optical pulses. Final report, February 9-September 30, 1983

    International Nuclear Information System (INIS)

    Siegman, A.E.

    1983-12-01

    The very great potential contactless, very high speed, very flexible, on-chip testing, diagnostics and measurement of very fast semiconductor circuits and devices has led us to initiate a small program to investigate such applications, using our own familiarity with picosecond pulse techniques, in conjunction with the integrated circuits skills present in Stanford's Integrated Circuit Laboratory (ICL), Solid State Laboratory (SSL), and the newly established Center for Integrated Systems. We plan to carry out first a rather straightforward set of picosecond pulse measurements on polysilicon photodetectors or photoswitches, such as can be very conveniently fabricated onto silicon integrated circuits using standard IC techniques, to serve as on-chip, optically addressable test or diagnostic points. (Such test points may in fact be fabricated directly into the active portion of the IC, or as test points in the disposable Kerr region between chips, for access during initial fabrication only). We are therefore assembling the necessary laser system for these measurements, and in addition beginning the fabrication of silicon test devices in collaboration with Professor Robert Dutton of the Integrated Circuit Laboratory and CIS. While making these preparations we have also carried out a literature review of the current state-of-the-art in such electrooptic devices. Some of the results of this study are summarized

  12. Spectroscopic vector analysis for fast pattern quality monitoring

    Science.gov (United States)

    Sohn, Younghoon; Ryu, Sungyoon; Lee, Chihoon; Yang, Yusin

    2018-03-01

    In semiconductor industry, fast and effective measurement of pattern variation has been key challenge for assuring massproduct quality. Pattern measurement techniques such as conventional CD-SEMs or Optical CDs have been extensively used, but these techniques are increasingly limited in terms of measurement throughput and time spent in modeling. In this paper we propose time effective pattern monitoring method through the direct spectrum-based approach. In this technique, a wavelength band sensitive to a specific pattern change is selected from spectroscopic ellipsometry signal scattered by pattern to be measured, and the amplitude and phase variation in the wavelength band are analyzed as a measurement index of the pattern change. This pattern change measurement technique is applied to several process steps and verified its applicability. Due to its fast and simple analysis, the methods can be adapted to the massive process variation monitoring maximizing measurement throughput.

  13. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique.

    Science.gov (United States)

    Khan, Md Rajibur Rahaman; Kang, Shin-Won

    2016-11-09

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal's pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R² is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry-Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.

  14. Wide-band analog frequency modulation of optic signals using indirect techniques

    Science.gov (United States)

    Fitzmartin, D. J.; Balboni, E. J.; Gels, R. G.

    1991-01-01

    The wideband frequency modulation (FM) of an optical carrier by a radio frequency (RF) or microwave signal can be accomplished independent of laser type when indirect modulation is employed. Indirect modulators exploit the integral relation of phase to frequency so that phase modulators can be used to impress frequency modulation on an optical carrier. The use of integrated optics phase modulators, which are highly linear, enables the generation of optical wideband FM signals with very low intermodulation distortion. This modulator can be used as part of an optical wideband FM link for RF and microwave signals. Experimental results from the test of an indirect frequency modulator for an optical carrier are discussed.

  15. Monitoring of Emissions From a Refinery Tank Farm Using a Combination of Optical Remote Sensing Techniques

    Science.gov (United States)

    Polidori, A.; Tisopulos, L.; Pikelnaya, O.; Mellqvist, J.; Samuelsson, J.; Marianne, E.; Robinson, R. A.; Innocenti, F.; Finlayson, A.; Hashmonay, R.

    2016-12-01

    Despite great advances in reducing air pollution, the South Coast Air Basin (SCAB) still faces challenges to attain federal health standards for air quality. Refineries are large sources of ozone precursors and, hence contribute to the air quality problems of the region. Additionally, petrochemical facilities are also sources of other hazardous air pollutants (HAP) that adversely affect human health, for example aromatic hydrocarbons. In order to assure safe operation, decrease air pollution and minimize population exposure to HAP the South Coast Air Quality Management District (SCAQMD) has a number of regulations for petrochemical facilities. However, significant uncertainties still exist in emission estimates and traditional monitoring techniques often do not allow for real-time emission monitoring. In the fall of 2015 the SCAQMD, Fluxsense Inc., the National Physical Laboratory (NPL), and Atmosfir Optics Ltd. conducted a measurement study to characterize and quantify gaseous emissions from the tank farm of one of the largest oil refineries in the SCAB. Fluxsense used a vehicle equipped with Solar Occultation Flux (SOF), Differential Optical Absorption Spectroscopy (DOAS), and Extractive Fourier Transform Infrared (FTIR) spectroscopy instruments. Concurrently, NPL operated their Differential Absorption Lidar (DIAL) system. Both research groups quantified emissions from the entire tank farm and identified fugitive emission sources within the farm. At the same time, Atmosfir operated an Open Path FTIR (OP-FTIR) spectrometer along the fenceline of the tank farm. During this presentation we will discuss the results of the emission measurements from the tank farm of the petrochemical facility. Emission rates resulting from measurements by different ORS methods will be compared and discussed in detail.

  16. Evaluating interfacial adhesion properties of Pt/Ti thin-film by using acousto-optic technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hae Sung [Graduate School of Automotive Engineering, Seoul National University of Science and Technology, Seoul (Korea, Republic of); Didie, David; Yoshida, Sanichiro [Dept. of Chemistry and Physics, Southeastern Louisiana University, Hammond (United States); Park, Ik Keun [Dept. of Mechanical and Automotive Engineering, Seoul National University of Science and Technology, Seoul (Korea, Republic of)

    2016-06-15

    We propose an acousto-optic technique for the nondestructive evaluation of adhesion properties of a Pt/Ti thin-film interface. Since there are some problems encountered when using prevailing techniques to nondestructively evaluate the interfacial properties of micro/nano-scale thin-films, we applied an interferometer that combined the acoustic and optical methods. This technique is based on the Michelson interferometer but the resultant surface of the thin film specimen makes interference instead of the mirror when the interface is excited from the acoustic transducer at the driving frequency. The thin film shows resonance-like behavior at a certain frequency range, resulting in a low-contrast fringe pattern. Therefore, we represented quantitatively the change in fringe pattern as a frequency spectrum and discovered the possibility that the interfacial adhesion properties of a thin film can be evaluated using the newly proposed technique.

  17. Techniques for Effective Optical Noise Rejection in Amplitude-Modulated Laser Optical Radars for Underwater Three-Dimensional Imaging

    Directory of Open Access Journals (Sweden)

    Francucci M

    2010-01-01

    Full Text Available Amplitude-modulated (AM laser imaging is a promising technology for the production of accurate three-dimensional (3D images of submerged scenes. The main challenge is that radiation scattered off water gives rise to a disturbing signal (optical noise that degrades more and more the quality of 3D images for increasing turbidity. In this paper, we summarize a series of theoretical findings, that provide valuable hints for the development of experimental methods enabling a partial rejection of optical noise in underwater imaging systems. In order to assess the effectiveness of these methods, which range from modulation/demodulation to polarimetry, we carried out a series of experiments by using the laboratory prototype of an AM 3D imager ( = 405 nm for marine archaeology surveys, in course of realization at the ENEA Artificial Vision Laboratory (Frascati, Rome. The obtained results confirm the validity of the proposed methods for optical noise rejection.

  18. Techniques for Effective Optical Noise Rejection in Amplitude-Modulated Laser Optical Radars for Underwater Three-Dimensional Imaging

    Directory of Open Access Journals (Sweden)

    R. Ricci

    2010-01-01

    Full Text Available Amplitude-modulated (AM laser imaging is a promising technology for the production of accurate three-dimensional (3D images of submerged scenes. The main challenge is that radiation scattered off water gives rise to a disturbing signal (optical noise that degrades more and more the quality of 3D images for increasing turbidity. In this paper, we summarize a series of theoretical findings, that provide valuable hints for the development of experimental methods enabling a partial rejection of optical noise in underwater imaging systems. In order to assess the effectiveness of these methods, which range from modulation/demodulation to polarimetry, we carried out a series of experiments by using the laboratory prototype of an AM 3D imager (λ = 405 nm for marine archaeology surveys, in course of realization at the ENEA Artificial Vision Laboratory (Frascati, Rome. The obtained results confirm the validity of the proposed methods for optical noise rejection.

  19. The application of neural network techniques to magnetic and optical inverse problems

    International Nuclear Information System (INIS)

    Jones, H.V.

    2000-12-01

    The processing power of the computer has increased at unimaginable rates over the last few decades. However, even today's fastest computer can take several hours to find solutions to some mathematical problems; and there are instances where a high powered supercomputer may be impractical, with the need for near instant solutions just as important (such as in an on-line testing system). This led us to believe that such complex problems could be solved using a novel approach, whereby the system would have prior knowledge about the expected solutions through a process of learning. One method of approaching this kind of problem is through the use of machine learning. Just as a human can be trained and is able to learn from past experiences, a machine is can do just the same. This is the concept of neural networks. The research which was conducted involves the investigation of various neural network techniques, and their applicability to solve some known complex inverse problems in the field of magnetic and optical recording. In some cases a comparison is also made to more conventional methods of solving the problems, from which it was possible to outline some key advantages of using a neural network approach. We initially investigated the application of neural networks to transverse susceptibility data in order to determine anisotropy distributions. This area of research is proving to be very important, as it gives us information about the switching field distribution, which then determines the minimum transition width achievable in a medium, and affects the overwrite characteristics of the media. Secondly, we investigated a similar situation, but applied to an optical problem. This involved the determination of important compact disc parameters from the diffraction pattern of a laser from a disc. This technique was then intended for use in an on-line testing system. Finally we investigated another area of neural networks with the analysis of magnetisation maps and

  20. Automatic Detection of Optic Disc in Retinal Image by Using Keypoint Detection, Texture Analysis, and Visual Dictionary Techniques

    Directory of Open Access Journals (Sweden)

    Kemal Akyol

    2016-01-01

    Full Text Available With the advances in the computer field, methods and techniques in automatic image processing and analysis provide the opportunity to detect automatically the change and degeneration in retinal images. Localization of the optic disc is extremely important for determining the hard exudate lesions or neovascularization, which is the later phase of diabetic retinopathy, in computer aided eye disease diagnosis systems. Whereas optic disc detection is fairly an easy process in normal retinal images, detecting this region in the retinal image which is diabetic retinopathy disease may be difficult. Sometimes information related to optic disc and hard exudate information may be the same in terms of machine learning. We presented a novel approach for efficient and accurate localization of optic disc in retinal images having noise and other lesions. This approach is comprised of five main steps which are image processing, keypoint extraction, texture analysis, visual dictionary, and classifier techniques. We tested our proposed technique on 3 public datasets and obtained quantitative results. Experimental results show that an average optic disc detection accuracy of 94.38%, 95.00%, and 90.00% is achieved, respectively, on the following public datasets: DIARETDB1, DRIVE, and ROC.