WorldWideScience

Sample records for optical spectrophotometric observations

  1. Spectrophotometric observations of very low ionization HII regions in the LMC

    International Nuclear Information System (INIS)

    Pena, M.; Ruiz, M.T.; Rubio, M.

    1987-01-01

    Optical spectrophotometric observations of 17 very low ionization HII regions of the LMC are reported. Physical conditions and chemical composition of these objects are derived from the emission line intensities. The average chemical abundances obtained are: log O/H=8.49+-0.08, log N/H=6.91+-0.07 and log S/H=6.89+-0.10. We do not find evidence of any composition gradient in the LMC. The HII regions in the vicinity of the detected molecular cloud complexes show higher nebular reddening. (Author)

  2. Spectrophotometric observations of symbiotic stars

    International Nuclear Information System (INIS)

    Ipatov, A.P.; Yudin, B.F.

    1985-01-01

    The data of spectrophotometric observations of symbiotic stars Z And, AX Per, CI Cyg, BF Cyg, YY Her, V 443 Her, AG Dra, AG Peg, AS 296, EG And, V 1016 Cyg, and HM Sge are presented. The spectral range of observations is 3300-7500 A, resolution is 50 A. The data obtained allowed to reveal specific characteristics inherent to the radiation of symbiotic stars and to estimate the parameters of their individual components. Analysis of the spectra of symbiotic stars in the range of 1300-7500 A wavelengths suggests a hypothesis, according to which a hot source in the Rayleigh - Jeans spectral range has a less steep inclination in the energy distribution, than a black-body one. A disk, formed during cold star substance accretion through an internal Lagrangian point onto a denser component of the system, can play the role of the source. In this case one manages to obtain the energy distribution in the symbiotic star spectrum consistent with the observed distribution

  3. A new optical sensor for spectrophotometric determination of uranium (VI) and thorium (IV) in acidic medium

    Energy Technology Data Exchange (ETDEWEB)

    Elhefnawy, O.A. [Nuclear and Radiological Regulatory Authority (NRRA), Cairo (Egypt). Nuclear Safeguards and Physical Protection Dept.

    2017-07-01

    A spectrophotometric method was developed for U(VI) and Th(IV) determination in acidic medium by using proposed optical sensor. This sensor is base on the complexation reaction of the ionophore midodrine hydrochloride (L) with U(VI)/Th(IV) in plasticized (o-NPOE) high molecular weight (PVC). Several parameters such as effect of acidic medium, response time and sensor compositions were studied. The determination of the complexes stoichiometry was also studied using Job's method. The complexes stoichiometry were measured at the absorbance spectra 302 nm and the results were found to be 1:1 for both complexes U(VI)-L and Th(IV)-L. The complexation reaction was extremely rapid at room temperature; it takes 5, 10 min to complete the complexation reaction in U(VI) and Th(IV), respectively. Under the optimum conditions the calibration curves of U(VI)/Th(IV) determination, have good linearity at different acidic medium nitric, sulfuric, and phosphoric acids with low detection and quantification limits. The accuracy and precision studies proved that the proposed optical sensor is valid and qualified for U(VI)/Th(IV) spectrophotometric determination in different acidic medium. The selectivity of the proposed optical sensor was studied. The proposed optical sensor was applied successfully for U(VI)/Th(IV) determination in research and development (R and D) nuclear waste samples with satisfactory results. A comparative study of the proposed optical sensor with other previous spectrophotometric sensors for U(VI)/Th(IV) determination, proved the high efficiency of the proposed optical sensor, that it presents wide linear range and low detection limit. The proposed optical sensor could be applied for a quantitative determination of U(VI)/Th(IV) in acidic waste samples.

  4. A new optical sensor for spectrophotometric determination of uranium (VI) and thorium (IV) in acidic medium

    International Nuclear Information System (INIS)

    Elhefnawy, O.A.

    2017-01-01

    A spectrophotometric method was developed for U(VI) and Th(IV) determination in acidic medium by using proposed optical sensor. This sensor is base on the complexation reaction of the ionophore midodrine hydrochloride (L) with U(VI)/Th(IV) in plasticized (o-NPOE) high molecular weight (PVC). Several parameters such as effect of acidic medium, response time and sensor compositions were studied. The determination of the complexes stoichiometry was also studied using Job's method. The complexes stoichiometry were measured at the absorbance spectra 302 nm and the results were found to be 1:1 for both complexes U(VI)-L and Th(IV)-L. The complexation reaction was extremely rapid at room temperature; it takes 5, 10 min to complete the complexation reaction in U(VI) and Th(IV), respectively. Under the optimum conditions the calibration curves of U(VI)/Th(IV) determination, have good linearity at different acidic medium nitric, sulfuric, and phosphoric acids with low detection and quantification limits. The accuracy and precision studies proved that the proposed optical sensor is valid and qualified for U(VI)/Th(IV) spectrophotometric determination in different acidic medium. The selectivity of the proposed optical sensor was studied. The proposed optical sensor was applied successfully for U(VI)/Th(IV) determination in research and development (R and D) nuclear waste samples with satisfactory results. A comparative study of the proposed optical sensor with other previous spectrophotometric sensors for U(VI)/Th(IV) determination, proved the high efficiency of the proposed optical sensor, that it presents wide linear range and low detection limit. The proposed optical sensor could be applied for a quantitative determination of U(VI)/Th(IV) in acidic waste samples.

  5. Optical spectrophotometric atlas of Supernova 1987A in the LMC. I. The first 130 days

    International Nuclear Information System (INIS)

    Phillips, M.M.; Heathcote, S.R.; Hamuy, M.; Navarrete, M.

    1988-01-01

    Optical spectrophotometry of SN 1987A in the Large Magellanic Cloud (LMC) covering the first 5 months since outburst is presented. More than 80 spectra were obtained at Cerro Tololo over this period, mostly with the 2D-Frutti two-dimensional photon-counting detector on the 1-m telescope. The spectrophotometric calibration of the 2D-Frutti data is considered in detail. Through a comparison with broadband photometry, it is shown that the accuracy of the 2D-Frutti spectrophotometry is + or - 5 percent in absolute terms, and that the relative calibration for any single spectrum is accurate to + or - 3 percent. CCD spectrophotometry obtained on the first night of observation (Feb. 25, 1987) is also briefly discussed. Radial velocities for several prominent absorption and emission features are measured from these combined data. 13 references

  6. REVIEW ARTICLE: Spectrophotometric applications of digital signal processing

    Science.gov (United States)

    Morawski, Roman Z.

    2006-09-01

    Spectrophotometry is more and more often the method of choice not only in analysis of (bio)chemical substances, but also in the identification of physical properties of various objects and their classification. The applications of spectrophotometry include such diversified tasks as monitoring of optical telecommunications links, assessment of eating quality of food, forensic classification of papers, biometric identification of individuals, detection of insect infestation of seeds and classification of textiles. In all those applications, large numbers of data, generated by spectrophotometers, are processed by various digital means in order to extract measurement information. The main objective of this paper is to review the state-of-the-art methodology for digital signal processing (DSP) when applied to data provided by spectrophotometric transducers and spectrophotometers. First, a general methodology of DSP applications in spectrophotometry, based on DSP-oriented models of spectrophotometric data, is outlined. Then, the most important classes of DSP methods for processing spectrophotometric data—the methods for DSP-aided calibration of spectrophotometric instrumentation, the methods for the estimation of spectra on the basis of spectrophotometric data, the methods for the estimation of spectrum-related measurands on the basis of spectrophotometric data—are presented. Finally, the methods for preprocessing and postprocessing of spectrophotometric data are overviewed. Throughout the review, the applications of DSP are illustrated with numerous examples related to broadly understood spectrophotometry.

  7. SHARDS: An Optical Spectro-photometric Survey of Distant Galaxies

    Science.gov (United States)

    Pérez-González, Pablo G.; Cava, Antonio; Barro, Guillermo; Villar, Víctor; Cardiel, Nicolás; Ferreras, Ignacio; Rodríguez-Espinosa, José Miguel; Alonso-Herrero, Almudena; Balcells, Marc; Cenarro, Javier; Cepa, Jordi; Charlot, Stéphane; Cimatti, Andrea; Conselice, Christopher J.; Daddi, Emmanuele; Donley, Jennifer; Elbaz, David; Espino, Néstor; Gallego, Jesús; Gobat, R.; González-Martín, Omaira; Guzmán, Rafael; Hernán-Caballero, Antonio; Muñoz-Tuñón, Casiana; Renzini, Alvio; Rodríguez-Zaurín, Javier; Tresse, Laurence; Trujillo, Ignacio; Zamorano, Jaime

    2013-01-01

    We present the Survey for High-z Absorption Red and Dead Sources (SHARDS), an ESO/GTC Large Program carried out using the OSIRIS instrument on the 10.4 m Gran Telescopio Canarias (GTC). SHARDS is an ultra-deep optical spectro-photometric survey of the GOODS-N field covering 130 arcmin2 at wavelengths between 500 and 950 nm with 24 contiguous medium-band filters (providing a spectral resolution R ~ 50). The data reach an AB magnitude of 26.5 (at least at a 3σ level) with sub-arcsec seeing in all bands. SHARDS' main goal is to obtain accurate physical properties of intermediate- and high-z galaxies using well-sampled optical spectral energy distributions (SEDs) with sufficient spectral resolution to measure absorption and emission features, whose analysis will provide reliable stellar population and active galactic nucleus (AGN) parameters. Among the different populations of high-z galaxies, SHARDS' principal targets are massive quiescent galaxies at z > 1, whose existence is one of the major challenges facing current hierarchical models of galaxy formation. In this paper, we outline the observational strategy and include a detailed discussion of the special reduction and calibration procedures which should be applied to the GTC/OSIRIS data. An assessment of the SHARDS data quality is also performed. We present science demonstration results on the detection and study of emission-line galaxies (star-forming objects and AGNs) at z = 0-5. We also analyze the SEDs for a sample of 27 quiescent massive galaxies with spectroscopic redshifts in the range 1.0 UV-to-MIR SEDs of the massive quiescent galaxies at z = 1.0-1.4 are well described by an exponentially decaying star formation history with scale τ = 100-200 Myr, age around 1.5-2.0 Gyr, solar or slightly sub-solar metallicity, and moderate extinction, A(V) ~ 0.5 mag. We also find that galaxies with masses above M* are typically older than lighter galaxies, as expected in a downsizing scenario of galaxy formation. This

  8. SHARDS: AN OPTICAL SPECTRO-PHOTOMETRIC SURVEY OF DISTANT GALAXIES

    International Nuclear Information System (INIS)

    Pérez-González, Pablo G.; Cava, Antonio; Barro, Guillermo; Villar, Víctor; Cardiel, Nicolás; Espino, Néstor; Gallego, Jesús; Ferreras, Ignacio; Rodríguez-Espinosa, José Miguel; Balcells, Marc; Cepa, Jordi; Alonso-Herrero, Almudena; Cenarro, Javier; Charlot, Stéphane; Cimatti, Andrea; Conselice, Christopher J.; Daddi, Emmanuele; Elbaz, David; Donley, Jennifer; Gobat, R.

    2013-01-01

    We present the Survey for High-z Absorption Red and Dead Sources (SHARDS), an ESO/GTC Large Program carried out using the OSIRIS instrument on the 10.4 m Gran Telescopio Canarias (GTC). SHARDS is an ultra-deep optical spectro-photometric survey of the GOODS-N field covering 130 arcmin 2 at wavelengths between 500 and 950 nm with 24 contiguous medium-band filters (providing a spectral resolution R ∼ 50). The data reach an AB magnitude of 26.5 (at least at a 3σ level) with sub-arcsec seeing in all bands. SHARDS' main goal is to obtain accurate physical properties of intermediate- and high-z galaxies using well-sampled optical spectral energy distributions (SEDs) with sufficient spectral resolution to measure absorption and emission features, whose analysis will provide reliable stellar population and active galactic nucleus (AGN) parameters. Among the different populations of high-z galaxies, SHARDS' principal targets are massive quiescent galaxies at z > 1, whose existence is one of the major challenges facing current hierarchical models of galaxy formation. In this paper, we outline the observational strategy and include a detailed discussion of the special reduction and calibration procedures which should be applied to the GTC/OSIRIS data. An assessment of the SHARDS data quality is also performed. We present science demonstration results on the detection and study of emission-line galaxies (star-forming objects and AGNs) at z = 0-5. We also analyze the SEDs for a sample of 27 quiescent massive galaxies with spectroscopic redshifts in the range 1.0 < z ∼< 1.4. We discuss the improvements introduced by the SHARDS data set in the analysis of their star formation history and stellar properties. We discuss the systematics arising from the use of different stellar population libraries, typical in this kind of study. Averaging the results from the different libraries, we find that the UV-to-MIR SEDs of the massive quiescent galaxies at z = 1.0-1.4 are well

  9. SHARDS: AN OPTICAL SPECTRO-PHOTOMETRIC SURVEY OF DISTANT GALAXIES

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Gonzalez, Pablo G.; Cava, Antonio; Barro, Guillermo; Villar, Victor; Cardiel, Nicolas; Espino, Nestor; Gallego, Jesus [Departamento de Astrofisica, Facultad de CC. Fisicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Ferreras, Ignacio [Mullard Space Science Laboratory, University College London, Holmbury St Mary, Dorking, Surrey RH5 6NT (United Kingdom); Rodriguez-Espinosa, Jose Miguel; Balcells, Marc; Cepa, Jordi [Instituto de Astrofisica de Canarias, E-38200 La Laguna, Tenerife (Spain); Alonso-Herrero, Almudena [Instituto de Fisica de Cantabria, CSIC-Universidad de Cantabria, E-39005 Santander (Spain); Cenarro, Javier [Centro de Estudios de Fisica del Cosmos de Aragon, Plaza San Juan 1, Planta 2, E-44001 Teruel (Spain); Charlot, Stephane [Institut d' Astrophysique de Paris, CNRS, Universite Pierre and Marie Curie, UMR 7095, 98bis bd Arago, F-75014 Paris (France); Cimatti, Andrea [Dipartimento di Astronomia, Universita degli Studi di Bologna, I-40127 Bologna (Italy); Conselice, Christopher J. [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom); Daddi, Emmanuele; Elbaz, David [CEA, Laboratoire AIM, Irfu/SAp, F-91191 Gif-sur-Yvette (France); Donley, Jennifer [Los Alamos National Laboratory, Los Alamos, NM (United States); Gobat, R. [Laboratoire AIM-Paris-Saclay, CEA/DSM-CNRS-Universite Paris Diderot, Irfu/Service d' Astrophysique, CEA Saclay, Orme des Merisiers, F-91191 Gif-sur-Yvette (France); and others

    2013-01-01

    We present the Survey for High-z Absorption Red and Dead Sources (SHARDS), an ESO/GTC Large Program carried out using the OSIRIS instrument on the 10.4 m Gran Telescopio Canarias (GTC). SHARDS is an ultra-deep optical spectro-photometric survey of the GOODS-N field covering 130 arcmin{sup 2} at wavelengths between 500 and 950 nm with 24 contiguous medium-band filters (providing a spectral resolution R {approx} 50). The data reach an AB magnitude of 26.5 (at least at a 3{sigma} level) with sub-arcsec seeing in all bands. SHARDS' main goal is to obtain accurate physical properties of intermediate- and high-z galaxies using well-sampled optical spectral energy distributions (SEDs) with sufficient spectral resolution to measure absorption and emission features, whose analysis will provide reliable stellar population and active galactic nucleus (AGN) parameters. Among the different populations of high-z galaxies, SHARDS' principal targets are massive quiescent galaxies at z > 1, whose existence is one of the major challenges facing current hierarchical models of galaxy formation. In this paper, we outline the observational strategy and include a detailed discussion of the special reduction and calibration procedures which should be applied to the GTC/OSIRIS data. An assessment of the SHARDS data quality is also performed. We present science demonstration results on the detection and study of emission-line galaxies (star-forming objects and AGNs) at z = 0-5. We also analyze the SEDs for a sample of 27 quiescent massive galaxies with spectroscopic redshifts in the range 1.0 < z {approx}< 1.4. We discuss the improvements introduced by the SHARDS data set in the analysis of their star formation history and stellar properties. We discuss the systematics arising from the use of different stellar population libraries, typical in this kind of study. Averaging the results from the different libraries, we find that the UV-to-MIR SEDs of the massive quiescent galaxies at

  10. Determination of free acidity in nuclear fuel reprocessing streams by fiber optic aided spectrophotometric technique

    International Nuclear Information System (INIS)

    Ganesh, S.; Velavendan, P.; Pandey, N.K.; Kamachi Mudali, U.; Natarajan, R.

    2014-01-01

    A fiber optic aided spectrophotometric technique has been developed for the determination of free acidity in nuclear fuel reprocessing streams. The developed method is simple, accurate and applicable to all ranges of nitric acid and heavy metal concentrations relevant to the purex process. The method is based on the formation of yellow colour with an acid-sensitive indicator such as chrome azurol s, the intensity of yellow colour is proportional to the acid concentration. The system obeys Lambert-Beer's law at 455 nm in the range of acidity 1-10 M of nitric acid. The results obtained are reproducible with standard deviation 2% and relative error is less than 3%. The results obtained by the developed technique are in good agreement with those obtained by the standard procedure. This method is adaptable for remote operation and on-line monitoring. (author)

  11. CATALYTIC KINETIC SPECTROPHOTOMETRIC DETERMINATION ...

    African Journals Online (AJOL)

    Preferred Customer

    acetylchlorophosphonazo(CPApA) by hydrogen peroxide in 0.10 M phosphoric acid. A novel catalytic kinetic-spectrophotometric method is proposed for the determination of copper based on this principle. Copper(II) can be determined spectrophotometrically ...

  12. Spectrophotometric characterization of hemozoin as a malaria biomarker

    Science.gov (United States)

    Silva, Ivo; Lima, Rui; Minas, Graça.; Catarino, Susana O.

    2017-08-01

    Malaria is a parasitic disease with more than a billion people worldwide at risk of contraction. The disease is predominantly widespread in regions with precarious healthcare conditions and resources. Despite the several available malaria diagnostic methods, only two are predominantly used in the field in malaria-endemic countries: microscopy and rapid diagnostic tests. In this work, an alternative diagnostic system is proposed, based on optical absorption spectrophotometry. The main objective of this paper is the spectrophotometric study of hemozoin as a malaria biomarker, since it is a sub-product of the malaria infection. The optical absorbance of hemoglobin and hemozoin solutions in purified water was measured in the visible spectrum range using a spectrophotometric setup. The results showed main absorbance peaks at 540 nm and 574 nm for hemoglobin, and at 672 nm for hemozoin. The tests performed in aqueous solutions have shown that both hemoglobin and synthetic hemozoin, when alone in solution, were detected by absorbance, with sensitivity of 0.05 g/L, and with a high linearity (R2> 0.92 for all wavelength peaks). Furthermore, it was found that the whole blood and the hemoglobin spectra have similar absorption peaks. By combining whole blood and synthetic hemozoin solutions, it was proved that both the hemozoin and the hemoglobin absorbance peaks could still be detected by spectrophotometry. For instance, in polydimethylsiloxane wells, the proposed method was able to detect hemozoin in whole blood samples for optical paths as low as 3 mm in cylindrical wells, thus proving the capability for this method's miniaturization. With this work, it is possible to conclude that hemozoin is a viable candidate as a biomarker for malaria detection by optical absorption spectrophotometry and also, that an autonomous, fully integrated and low cost miniaturized system, based on such a principle, could provide an efficient diagnosis of malaria.

  13. Spectro-photometric calibration of the SuperNova Integral Field Spectrograph in the Nearby Supernova Factory collaboration framework

    International Nuclear Information System (INIS)

    Buton, Clement

    2009-01-01

    Ten years ago, type Ia supernovae used as distances indicators led to the discovery of the accelerating expansion of the universe. Today, a second generation of surveys has significantly increased the high-redshift type Ia supernovae sample. The low-redshift sample was however still limiting the cosmological analysis using SNe. In this framework, the Nearby Supernova Factory has followed 200 nearby type Ia supernovae using the dedicated Supernovae Integral Field Spectrograph with spectro-photometric capacities. My PhD thesis has been carried out at the Institut de Physique Nucleaire de Lyon and at the Lawrence Berkeley National Laboratory in the framework of the international cosmological project SNfactory. In order to reach the design spectrophotometric accuracy, attention has been focused on several key aspects of the calibration procedure, including: determination of a dedicated point spread function for 3D point source extraction, estimating the nightly photometric quality, derivation of the nightly sky extinction over the extended optical domain, its modeling in terms of physical components and its variability within a given night. A full multi-standards calibration pipeline has been implemented using approximately 4000 observations of spectrophotometric standard stars taken throughout the night over nearly 500 individual nights. Preliminary scientific results of the whole SNfactory collaboration will be presented at the end of this thesis. (author)

  14. Evaluation of the Esthetic Properties of Developmental Defects of Enamel: A Spectrophotometric Clinical Study

    Directory of Open Access Journals (Sweden)

    Fabrizio Guerra

    2015-01-01

    Full Text Available Objectives. Detailed clinical quantification of optical properties of developmental defect of enamel is possible with spectrophotometric evaluation. Developmental defects of enamel (DDE are daily encountered in clinical practice. DDE are an alteration in quality and quantity of the enamel, caused by disruption and/or damage to the enamel organ during amelogenesis. Methods. Several clinical indices have been developed to categorize enamel defects based on their nature, appearance, microscopic features, or cause. A sample of 39 permanent teeth presenting DDE on labial surface was examined using the DDE Modified Index and SpectroShade evaluation. The spectrophotometric approach quantifies L* (luminosity, a* (quantity of green-red, and b* (quantity of blue-yellow of different DDE. Conclusions. SpectroShade evaluation of the optical properties of the enamel defect enhances clinical understanding of severity and extent of the defect and characterizes the enamel alteration in terms of color discrepancy and surface characterization.

  15. Spectrophotometric Analysis of Caffeine

    Directory of Open Access Journals (Sweden)

    Showkat Ahmad Bhawani

    2015-01-01

    Full Text Available The nature of caffeine reveals that it is a bitter white crystalline alkaloid. It is a common ingredient in a variety of drinks (soft and energy drinks and is also used in combination with various medicines. In order to maintain the optimum level of caffeine, various spectrophotometric methods have been developed. The monitoring of caffeine is very important aspect because of its consumption in higher doses that can lead to various physiological disorders. This paper incorporates various spectrophotometric methods used in the analysis of caffeine in various environmental samples such as pharmaceuticals, soft and energy drinks, tea, and coffee. A range of spectrophotometric methodologies including chemometric techniques and derivatization of spectra have been used to analyse the caffeine.

  16. Spectrophotometric calibration system for DECam

    Science.gov (United States)

    Rheault, J.-P.; DePoy, D. L.; Marshall, J. L.; Prochaska, T.; Allen, R.; Wise, J.; Martin, E.; Williams, P.

    2012-09-01

    We describe a spectrophotometric calibration system that is being implemented as part of the DES DECam project at the Blanco 4 meter at CTIO. Our calibration system uses a 1nm wide tunable source to measure the instrumental response function of the telescope optics and detector from 300nm up to 1100nm. This calibration will be performed regularly to monitor any change in the transmission function of the telescope during the 5 year survey. The system consists of a monochromator based tunable light source that provides illumination on a dome flat that is monitored by calibrated photodiodes that allow us to measure the telescope throughput as a function of wavelength. Our system has a peak output power of 2 mW, equivalent to a flux of approximately 800 photons/s/pixel on DECam.

  17. Simultaneous Spectrophotometric Determination of Valsartan and ...

    African Journals Online (AJOL)

    Purpose: To develop a direct, simple and extraction-free spectrophotometric method for the simultaneous estimation of valsartan and ezetimibe in pharmaceuticals. Methods: A spectrophotometric method for the determination of valsartan and ezetimibe was developed using acidic dyes, namely, bromophenol blue (BPB) ...

  18. A Sensitive Validated Spectrophotometric Method for the Determination of Flucloxacillin Sodium

    Directory of Open Access Journals (Sweden)

    R. Singh Gujral

    2009-01-01

    Full Text Available A simple and sensitive spectrophotometric method has been proposed for the determination of flucloxacillin sodium. The determination method is based on charge transfer complexation reaction of the drug with iodine in methanol-dichloromethane medium. The absorbance was measured at 362 nm against the reagent blank. Under optimized experimental conditions, Beer's law is obeyed in the concentration ranges 1-9 μg/mL for flucloxacillin. The method was validated for specificity, linearity, precision, accuracy. The degree of linearity of the calibration curves, the percent recoveries, limit of detection and quantitation for the spectrophotometric method were determined. No interferences could be observed from the additives commonly present in the pharmaceutical formulations. The method was successfully applied for in vitro determination of human urine samples with low RSD value. This is simple, specific, accurate and sensitive spectrophotometric method.

  19. The Gaia spectrophotometric standard stars survey: II. Instrumental effects of six ground-based observing campaigns

    Science.gov (United States)

    Altavilla, G.; Marinoni, S.; Pancino, E.; Galleti, S.; Ragaini, S.; Bellazzini, M.; Cocozza, G.; Bragaglia, A.; Carrasco, J. M.; Castro, A.; Di Fabrizio, L.; Federici, L.; Figueras, F.; Gebran, M.; Jordi, C.; Masana, E.; Schuster, W.; Valentini, G.; Voss, H.

    2015-08-01

    The Gaia SpectroPhotometric Standard Stars (SPSS) survey started in 2006, was awarded almost 450 observing nights and accumulated almost 100 000 raw data frames with both photometric and spectroscopic observations. Such large observational effort requires careful, homogeneous, and automatic data reduction and quality control procedures. In this paper, we quantitatively evaluate instrumental effects that might have a significant (i.e., ≥ 1 %) impact on the Gaia SPSS flux calibration. The measurements involve six different instruments, monitored over the eight years of observations dedicated to the Gaia flux standards campaigns: DOLORES@TNG in La Palma, EFOSC2@NTT and ROSS@REM in La Silla, CAFOS@2.2 m in Calar Alto, BFOSC@Cassini in Loiano, and LaRuca@1.5 m in San Pedro Mártir. We examine and quantitatively evaluate the following effects: CCD linearity and shutter times, calibration frames stability, lamp flexures, second order contamination, light polarization, and fringing. We present methods to correct for the relevant effects which can be applied to a wide range of observational projects at similar instruments. Based on data obtained with BFOSC@Cassini in Loiano, Italy; EFOSC2@NTT in La Silla, Chile; DOLORES@TNG in La Palma, Spain; CAFOS@2.2 m in Calar Alto, Spain; LaRuca@1.5 m in San Pedro Mártir, Mexico (see acknowledgements for more details).

  20. Spectrophotometric retinal oximetry in pigs

    DEFF Research Database (Denmark)

    Traustason, Sindri; Kiilgaard, Jens Folke; Karlsson, Robert

    2013-01-01

    PURPOSE: To assess the validity of spectrophotometric retinal oximetry, by comparison to blood gas analysis and intra-vitreal measurements of partial pressure of oxygen (pO2). METHODS: Female domestic pigs were used for all experiments (n=8). Oxygen fraction in inspired air was changed using...... a mixture of room air, pure oxygen and pure nitrogen, ranging from 5% to 100% oxygen. Femoral arterial blood gas analysis and retinal oximetry was performed at each level of inspiratory oxygen fraction. Retinal oximetry was performed using a commercial instrument, the Oxymap Retinal Oximeter T1 (Oxymap ehf...... arterial oxygen saturation and the optical density ratio over retinal arteries revealed an approximately linear relationship (R(2) = 0.74, p = 3.4 x 10(-9)). In order to test the validity of applying the arterial calibration to veins, we compared non-invasive oximetry measurements to invasive pO2...

  1. Spectrophotometric Determination of Ezetimibe

    Directory of Open Access Journals (Sweden)

    P. Baby Sudha Lakshmi

    2010-01-01

    Full Text Available Two simple, sensitive, selective and accurate spectro-photometric methods (Method A and Method B for the determination of eztimibe in bulk drug and pharmaceutical formulations (tablets have been described. Method A and B are based on the redox/complex formation reaction of drug with 1,10-phenanthroline and hexacyano-ferrate(III in presence of ferric chloride to form coloured chromogens exhibiting λmax at 510 and 740 nm respectively. The results of analysis for the two methods have been validated statistically and by recovery studies. The results are compared with those obtained using UV spectrophotometric method in alcohol at 231.7 nm.

  2. Building up a database of spectro-photometric standard stars from the UV to the near-IR: A status report

    NARCIS (Netherlands)

    Vernet, J.; Kerber, F.; Saitta, F.; Mainieri, V.; D'Odorico, S.; Lidman, C.; Mason, E.; Bohlin, R.C.; Rauch, T.; Ivanov, V.D.; Smette, A.; Walsh, J.R.; Fosbury, R.A.E.; Goldoni, P.; Groot, P.; Hammer, F.; Horrobin, M.; Kaper, L.; Kjaergaard-Rasmussen, P.; Pallavicini, R.; Royer, F.

    2008-01-01

    We present a project aimed at establishing a set of 12 spectro-photometric standards over a wide wavelength range from 320 to 2500 nm. Currently no such set of standard stars covering the near-IR is available. Our strategy is to extend the useful range of existing well-established optical flux

  3. Electro-Optics/Low Observables Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electro-Optics/Low Observables Laboratory supports graduate instruction for students enrolled in the Low Observables program. Its purpose is to introduce these...

  4. Spectrophotometric analysis of irradiated spices

    Energy Technology Data Exchange (ETDEWEB)

    Josimovic, L; Cudina, I

    1987-01-01

    Seven different spices (thyme, cinnamon, coriander, caraway, pimento, paprika, black pepper) were treated by gamma radiation at an absorbed dose of 10 kGy, and the effect on chemical quality was determined. The effects of this dose were assessed by spectrophotometric analysis of some water-soluble constituents of spices (carbohydrates; carbonyl compounds) and on the content of water-insoluble steam-volatile oils. The colour of paprika and the content of piperine in pepper held in different packaging materials were measured in unirradiated and irradiated samples as a function of storage time. In all cases irradiation does not bring about any distinct qualitative or quantitative chemical changes based on spectrophotometric analysis of spice extracts.

  5. Binary stars observed with adaptive optics at the starfire optical range

    Energy Technology Data Exchange (ETDEWEB)

    Drummond, Jack D. [Air Force Research Laboratory, Directed Energy Directorate, RDSAM, 3550 Aberdeen Avenue SE, Kirtland AFB, NM 87117-5776 (United States)

    2014-03-01

    In reviewing observations taken of binary stars used as calibration objects for non-astronomical purposes with adaptive optics on the 3.5 m Starfire Optical Range telescope over the past 2 years, one-fifth of them were found to be off-orbit. In order to understand such a high number of discrepant position angles and separations, all previous observations in the Washington Double Star Catalog for these rogue binaries were obtained from the Naval Observatory. Adding our observations to these yields new orbits for all, resolving the discrepancies. We have detected both components of γ Gem for the first time, and we have shown that 7 Cam is an optical pair, not physically bound.

  6. UV Spectrophotometric Method for Determination of Cinitapride in Pure and its Solid Dosage Form

    Directory of Open Access Journals (Sweden)

    B. Thangabalan

    2009-01-01

    Full Text Available A new, rapid, precise, accurate and sensitive analytical method was developed for the UV spectrophotometric assay of cinitapride (CTP. The drug obeyed the Beer's law and showed good correlation. It showed absorption maxima at 260 nm in methanol. The linearity was observed between 5-40 µg mL-1. The results of analysis were validated by recovery studies. The recovery was more than 99%. The proposed method is the only method available for spectrophotometric determination of the drug. It is simple, precise, sensitive and reproducible and can be used for the routine quality control testing of the marketed formulations.

  7. Incipient fault diagnosis of power transformers using optical spectro-photometric technique

    Science.gov (United States)

    Hussain, K.; Karmakar, Subrata

    2015-06-01

    Power transformers are the vital equipment in the network of power generation, transmission and distribution. Mineral oil in oil-filled transformers plays very important role as far as electrical insulation for the winding and cooling of the transformer is concerned. As transformers are always under the influence of electrical and thermal stresses, incipient faults like partial discharge, sparking and arcing take place. As a result, mineral oil deteriorates there by premature failure of the transformer occurs causing huge losses in terms of revenue and assets. Therefore, the transformer health condition has to be monitored continuously. The Dissolved Gas Analysis (DGA) is being extensively used for this purpose, but it has some drawbacks like it needs carrier gas, regular instrument calibration, etc. To overcome these drawbacks, Ultraviolet (UV) -Visible and Fourier Transform Infrared (FTIR) Spectro-photometric techniques are used as diagnostic tools for investigating the degraded transformer oil affected by electrical, mechanical and thermal stresses. The technique has several advantages over the conventional DGA technique.

  8. In situ spectrophotometric measurement of dissolved inorganic carbon in seawater

    Science.gov (United States)

    Liua, Xuewu; Byrne, Robert H.; Adornato, Lori; Yates, Kimberly K.; Kaltenbacher, Eric; Ding, Xiaoling; Yang, Bo

    2013-01-01

    Autonomous in situ sensors are needed to document the effects of today’s rapid ocean uptake of atmospheric carbon dioxide (e.g., ocean acidification). General environmental conditions (e.g., biofouling, turbidity) and carbon-specific conditions (e.g., wide diel variations) present significant challenges to acquiring long-term measurements of dissolved inorganic carbon (DIC) with satisfactory accuracy and resolution. SEAS-DIC is a new in situ instrument designed to provide calibrated, high-frequency, long-term measurements of DIC in marine and fresh waters. Sample water is first acidified to convert all DIC to carbon dioxide (CO2). The sample and a known reagent solution are then equilibrated across a gas-permeable membrane. Spectrophotometric measurement of reagent pH can thereby determine the sample DIC over a wide dynamic range, with inherent calibration provided by the pH indicator’s molecular characteristics. Field trials indicate that SEAS-DIC performs well in biofouling and turbid waters, with a DIC accuracy and precision of ∼2 μmol kg–1 and a measurement rate of approximately once per minute. The acidic reagent protects the sensor cell from biofouling, and the gas-permeable membrane excludes particulates from the optical path. This instrument, the first spectrophotometric system capable of automated in situ DIC measurements, positions DIC to become a key parameter for in situ CO2-system characterizations.

  9. Spectrophotometric Investigations of Macrolide Antibiotics: A Brief Review

    Directory of Open Access Journals (Sweden)

    Mrudul R. Keskar

    2015-01-01

    Full Text Available Macrolides, one of the most commonly used class of antibiotics, are a group of drugs produced by Streptomyces species. They belong to the polyketide class of natural products. Their activity is due to the presence of a large macrolide lactone ring with deoxy sugar moieties. They are protein synthesis inhibitors and broad-spectrum antibiotics, active against both gram-positive and gram-negative bacteria. Different analytical techniques have been reported for the determination of macrolides such as chromatographic methods, flow injection methods, spectrofluorometric methods, spectrophotometric methods, and capillary electrophoresis methods. Among these methods, spectrophotometric methods are sensitive and cost effective for the analysis of various antibiotics in pharmaceutical formulations as well as biological samples. This article reviews different spectrophotometric methods for the determination of macrolide antibiotics.

  10. Optical observations of Gamma-Ray Bursts

    International Nuclear Information System (INIS)

    Hjorth, J.; Pian, E.; Fynbo, J.P.U.

    2004-01-01

    We briefly review the status and recent progress in the field of optical observations of gamma-ray burst afterglows. We will focus on the fundamental observational evidence for the relationship between gamma-ray bursts and the final evolutionary phases of massive stars. In particular, we will address (i) gamma-ray burst host galaxies, (ii) optically dark gamma-ray burst afterglows, (iii) the gamma-ray burst-supernova connection, and (iv) the relation between X-ray flashes, gamma-ray bursts, and supernovae

  11. Optical observations of binary X-ray sources

    International Nuclear Information System (INIS)

    Boynton, P.E.

    1975-01-01

    The contribution to the recent progress in astronomy made by optical observations is pointed out. The optical properties of X-ray sources help to establish the physical nature of these objects. The current observational evidence on the binary X-ray sources HZ Her/Her X-1 and HDE 226868/Cyg X-1 is reported. (P.J.S.)

  12. Multicolor Photometric Observation of Lightning from Space: Comparison with Radio Measurements

    Science.gov (United States)

    Adachi, Toru; Cohen, Morris; Said, Ryan; Blakeslee, Richard J.; Cummer, Steven A.; Li, Jingbo; Lu, Geopeng; Hsu, Rue-Ron; Su, Han-Tzong; Chen, Alfred Bing-Chih; hide

    2011-01-01

    This study evaluates the effectiveness of spectrophotometric measurements from space in revealing properties of lightning flash. The multicolor optical waveform data obtained by FORMOSAT-2/Imager of Sprites and Upper Atmospheric Lightning (ISUAL) were analyzed in relation to National Lightning Detection Network (NLDN), North Alabama Lightning Mapping Array (LMA). As of July 2011, we found six lightning events which were observed by ISUAL and North Alabama LMA. In two of these events, NLDN showed clear positive cloud-to-ground (CG) discharges with peak current of +139.9 kA and +41.6 kA and, around that time, LMA showed continuous intra-cloud (IC) leader activities at 4-6 km altitudes. ISUAL also observed consistent optical waveforms of the IC and CG components and, interestingly, it was found that the blue/red spectral ratio clearly decreased by a factor of 1.5-2.5 at the time of CG discharges. Other four lightning events in which NLDN did not detect any CG discharges were also investigated, but such a feature was not found in any of these cases. These results suggest that the optical color of CG component is more reddish than that of IC component and we explain this as a result of more effective Rayleigh scattering in blue light emissions coming from lower-altitude light source. This finding suggests that spectral measurements could be a new useful technique to characterize ICs and CGs from space. In this talk, we will also present a result from lightning statistical analysis of ISUAL spectrophotometric data and ULF magnetic data.

  13. Differential spectrophotometric determination of plutonium

    International Nuclear Information System (INIS)

    Lecat, J.

    1980-01-01

    Differential spectrophotometric method is used for determination of plutonium reduced to oxydation state III+ by ascorbic acid, at 560 nm. Concentration of solutions is 4 g/l and accuracy of the method is better than 0,3% [fr

  14. Discovery of the optical counterpart and early optical observations of GRB 990712

    DEFF Research Database (Denmark)

    Sahu, K.C.; Vreesvijk, P.; Bakos, G.

    2000-01-01

    We present the discovery observations of the optical counterpart of the gamma-ray burst GRB 990712 taken 4.16 hr after the outburst and discuss its light curve observed in the V, R, and I bands during the first similar to 35 days after the outburst. The observed light curves were fitted with a po......We present the discovery observations of the optical counterpart of the gamma-ray burst GRB 990712 taken 4.16 hr after the outburst and discuss its light curve observed in the V, R, and I bands during the first similar to 35 days after the outburst. The observed light curves were fitted...

  15. Spectrophotometric method for quantitative measuring essential oil in aromatic water and distillate with rose smell

    International Nuclear Information System (INIS)

    Semenova, E; Moiseeva, I; Presnyakova, V; Goncharov, D; Goncharov, M; Presnyakova, E; Presnyakov, S; Kolesnikova, S

    2017-01-01

    In this connection, we improved the express methods of determining the mixture of volatile aromatic substances by the spectrophotometry of aromatic water and steam distillate of essential oil raw materials (traditional or biotechnological with rose smell). Direct spectrophotometry of distillation water is impossible because it is a colloid of liquid oil and law is not observed. Therefore, it is necessary to dissolve 1 ml of distillate in ethanol in the ratio 1:4, in this case we take real solution with no lipophilic fall-out on the walls of cuvette, also the light absorption law is observed. There are stable maximums in spectrums of studied oils. Optical density of these maximums is a result of summary absorption of terpenoid components (aromatic and monoterpene alcohols, its ethers). Optical density of tested and standard solutions is measured in appropriate wavelengths. Spectrophotometric method of determination of essential oil quantity in aromatic water with rose smell differs with high sensitivity (10 -5 -10 -6 gmol/l) and allows to determine oil concentration from 0,900 to 0,008 mg with an error less than 1%. At that, 1 ml is enough for analysis. It’s expedient to apply this method while operating with small quantity of water distillate in biochemical and biotechnological researches and also as express control for extraction and hydrodistillation of essential oil raw material (rose petals and flowers from different origin, eremothecium cultural liquid etc.). (paper)

  16. GRBs optical follow-up observation at Lunin observatory, Taiwan

    Energy Technology Data Exchange (ETDEWEB)

    Huang, K.Y.; Ip, W.H. [Chung-Li Univ., Taiwan (China). Institute of astronomy; Urata, Y. [RIKEN, Saitama (Japan); Tokyo Institute of Technology, Tokyo (Japan). Department of Physics; Tamagawa, T.; Onda, K. [RIKEN, Saitama (Japan); Makishima, K. [RIKEN, Saitama (Japan); Tokyo Univ., Tokyo (Japan). Department of Physics

    2005-07-15

    The Lulin GRB program, using the Lulin One-meter Telescope (LOT) in Taiwan started in July 2003. Its scientific aims are to discover optical counterparts of XRFs and short and long GRBs, then to quickly observe them in multiple bands. Thirteen follow-up observations were provided by LOT between July 2003 and Feb. 2005. One host galaxy was found at GRB 031203. Two optical afterglows were detected for GRB 040924 and GRB 041006. In addition, the optical observations of GRB 031203 and a discussion of the non-detection of the optical afterglow of GRB 031203 are also reported in this article.

  17. GRBs optical follow-up observation at Lunin observatory, Taiwan

    International Nuclear Information System (INIS)

    Huang, K.Y.; Ip, W.H.; Makishima, K.; Tokyo Univ., Tokyo

    2005-01-01

    The Lulin GRB program, using the Lulin One-meter Telescope (LOT) in Taiwan started in July 2003. Its scientific aims are to discover optical counterparts of XRFs and short and long GRBs, then to quickly observe them in multiple bands. Thirteen follow-up observations were provided by LOT between July 2003 and Feb. 2005. One host galaxy was found at GRB 031203. Two optical afterglows were detected for GRB 040924 and GRB 041006. In addition, the optical observations of GRB 031203 and a discussion of the non-detection of the optical afterglow of GRB 031203 are also reported in this article

  18. Observations of Early Optical Afterglows

    OpenAIRE

    Roming, Peter W. A.; Mason, Keith O.

    2006-01-01

    The Swift Ultra-Violet/Optical Telescope (UVOT) has performed extensive follow-up on 71 Swift Burst Alert Telescope triggered gamma-ray bursts (GRBs) in its first ten months of operations. In this paper, we discuss some of the UV and optical properties of UVOT detected afterglows such as XRF 050406, the bright GRB 050525A, the high redshift GRB 050730, the early flaring GRB 050801, and others. We also discuss some of the implications of why 75% of GRB afterglows observed by UVOT in less than ...

  19. Comparison of spectrophotometric and radioisotopic methods for the assay of Rubisco in ozone-treated plants

    International Nuclear Information System (INIS)

    Reid, C.D.; Tissue, D.T.; Fiscus, E.L.; Strain, B.R.

    1997-01-01

    Radioisotopic and spectrophotometric assays for ribulose-1,5-bisphosphate carboxylase/oxygenase (Rubisco) initial and final activities and Rubisco content were compared in plants chronically exposed to ozone (O 3 ) in a greenhouse and the field. In a greenhouse experiment, Glycine max was treated in exposure chambers with either charcoal-filtered air (CF air) or 100 nl O 3 l -1 for 6 h daily during vegetative growth. Samples were collected after 7 days of exposure. In a field experiment, G. max was treated in open-top chambers with either CF air or non-filtered air with O 3 added at 1.5 times ambient O 3 for 12 h daily. Average daily O 3 concentrations were 21 and 92 nl l -1 in the CF and O 3 treatments, respectively. Samples were collected during vegetative and reproductive growth. Both assays generally yielded comparable Rubisco initial and final activities for greenhouse-grown plants regardless of the O 3 treatment. However for field-grown plants, Rubisco initial and final activities average 15 and 23% lower when assayed by the spectrophotometric rather than the radioisotopic method. For Rubisco content estimated by the spectrophotometric method, lower values for the regression of Rubisco activity vs concentration of carboxyarabinitol-1.5-bisphosphate were observed in O 3- than in CF-treated plants. Both assays yielded comparable Rubisco contents in the greenhouse and in the field although the variation was larger with the spectrophotometric method in field-grown plants. Growth conditions, field vs greenhouse, were more critical to the spectrophotometric assay performance than the O 3 treatments for measurement of Rubisco activity and content. (au) 40 refs

  20. Optimization, Validation and Application of Spectrophotometric ...

    African Journals Online (AJOL)

    ... 3Research Center of Food and Drug Evaluation, Wuhan University, Wuhan 430071, ... Methods: Spectrophotometric HMG-CoA reductase detection in male Wistar ... protein expression in various regulatory ... reagents were analytical grade.

  1. Spectrophotometric determination of association constant

    DEFF Research Database (Denmark)

    2016-01-01

    Least-squares 'Systematic Trial-and-Error Procedure' (STEP) for spectrophotometric evaluation of association constant (equilibrium constant) K and molar absorption coefficient E for a 1:1 molecular complex, A + B = C, with error analysis according to Conrow et al. (1964). An analysis of the Charge...

  2. Spectrophotometric Methods for the Assay of Fluvoxamine Using Chromogenic Reagents

    Directory of Open Access Journals (Sweden)

    V. Annapurna

    2010-01-01

    Full Text Available Simple, accurate and reproducible UV-Visible spectrophotometric methods were established for the assay of FXA based on the oxidative coupling and condensation reactions. Condensation and coupling of the FXA with Ninhydrin-Ascorbic acid is proposed in method A. Method B includes complexation of FXA with cobalt thiocyanate. The ligating property of FXA with sodium nitro prusside is incorporated in method C. The optical characteristics such as Beers law limits, molar absorptivity and Sandell’s sensitivity for the methods (A-C are given. Regression analysis using the method of least squares was made to evaluate the slope(b, intercept(a and correlation coefficient (r and standard error of estimation (Se for each system. Determination of FXA in bulk form and in pharmaceutical formulations were also incorporated.

  3. Second derivative spectrophotometric determination of ...

    African Journals Online (AJOL)

    Hemn

    2013-11-13

    Nov 13, 2013 ... olanzapine in pharmaceutical formulation.Int.J.ChemTech. Res.2(1):756-761. Stanisz B, Paszun S, Lesniak M (2009). Validation of UV derivative spectrophotometric method for determination of benazepril hydrochloride in tablets and evaluation of its stability.ActaPoloniaePharmaceutica-Drug Research.

  4. Development of Vanadometric System for Spectrophotometric ...

    African Journals Online (AJOL)

    rugged, and compares well with some complex methods for assay of timolol maleate in ... 3-[[4-(4-morpholinyl)-1, 2, 5-thiadiazol-3-yl] oxy]- ... preparation methods, costly reagents, expertise ..... chemical characterization, UV spectrophotometric.

  5. EXCESS OPTICAL ENHANCEMENT OBSERVED WITH ARCONS FOR EARLY CRAB GIANT PULSES

    Energy Technology Data Exchange (ETDEWEB)

    Strader, M. J.; Mazin, B. A.; Spiro Jaeger, G. V.; Gwinn, C. R.; Meeker, S. R.; Szypryt, P.; Van Eyken, J. C.; Marsden, D.; Walter, A. B.; Ulbricht, G. [Department of Physics, University of California, Santa Barbara, CA 93106 (United States); Johnson, M. D. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); O' Brien, K. [Department of Physics, University of Oxford, Denys Wilkinson Building, Keble Road, Oxford OX1 3RH (United Kingdom); Stoughton, C. [Fermilab Center for Particle Astrophysics, Batavia, IL 60510 (United States); Bumble, B. [NASA Jet Propulsion Laboratory, 4800 Oak Grove Drive, Pasadena, CA 91125 (United States)

    2013-12-10

    We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARray Camera for Optical to Near-IR Spectrophotometry, a unique superconducting energy-resolving photon-counting array at the Palomar 200 inch telescope. At radio wavelengths, we observe with the Robert C. Byrd Green Bank Telescope and the Green Bank Ultimate Pulsar Processing Instrument backend. We see an 11.3% ± 2.5% increase in peak optical flux for pulses that have an accompanying giant radio pulse arriving near the peak of the optical main pulse, in contrast to a 3.2% ± 0.5% increase when an accompanying giant radio pulse arrives soon after the optical peak. We also observe that the peak of the optical main pulse is 2.8% ± 0.8% enhanced when there is a giant radio pulse accompanying the optical interpulse. We observe no statistically significant spectral differences between optical pulses accompanied by and not accompanied by giant radio pulses. Our results extend previous observations of optical-radio correlation to the time and spectral domains. Our refined temporal correlation suggests that optical and radio emission are indeed causally linked, and the lack of spectral differences suggests that the same mechanism is responsible for all optical emission.

  6. EXCESS OPTICAL ENHANCEMENT OBSERVED WITH ARCONS FOR EARLY CRAB GIANT PULSES

    International Nuclear Information System (INIS)

    Strader, M. J.; Mazin, B. A.; Spiro Jaeger, G. V.; Gwinn, C. R.; Meeker, S. R.; Szypryt, P.; Van Eyken, J. C.; Marsden, D.; Walter, A. B.; Ulbricht, G.; Johnson, M. D.; O'Brien, K.; Stoughton, C.; Bumble, B.

    2013-01-01

    We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARray Camera for Optical to Near-IR Spectrophotometry, a unique superconducting energy-resolving photon-counting array at the Palomar 200 inch telescope. At radio wavelengths, we observe with the Robert C. Byrd Green Bank Telescope and the Green Bank Ultimate Pulsar Processing Instrument backend. We see an 11.3% ± 2.5% increase in peak optical flux for pulses that have an accompanying giant radio pulse arriving near the peak of the optical main pulse, in contrast to a 3.2% ± 0.5% increase when an accompanying giant radio pulse arrives soon after the optical peak. We also observe that the peak of the optical main pulse is 2.8% ± 0.8% enhanced when there is a giant radio pulse accompanying the optical interpulse. We observe no statistically significant spectral differences between optical pulses accompanied by and not accompanied by giant radio pulses. Our results extend previous observations of optical-radio correlation to the time and spectral domains. Our refined temporal correlation suggests that optical and radio emission are indeed causally linked, and the lack of spectral differences suggests that the same mechanism is responsible for all optical emission

  7. K4 Fe(CN)6 as a spectrophotometric agent for uranium analysis

    International Nuclear Information System (INIS)

    Soedyartomo; Tarwita.

    1976-01-01

    The properties of K 4 Fe(CN) 6 as a spectrophotometric agent for Uranium analysis was observed by putting some experiment into practice. The experiment covers the observation of expanding colour stability, the optimization of operating condition (p,H. and wavelength), the effect of K 4 Fe(CN) 6 concentration and the preparation of its standard curves (transmitansion vs uranium concentration) and the observation of the interfering metal spectra s (Cu ++ , Fe ++ ) either of its mixtures or themselves alone, has been carried out. The result and discussion on it are given. (author)

  8. Separation and spectrophotometric determination of elements

    International Nuclear Information System (INIS)

    Marczenko, Z.

    1986-01-01

    This book is a useful text intended as a reference for the laboratory that is either involved in spectrophotometric analysis or requires separations prior to analysis by any method. It attempts to cover a diverse series of topics in fewer than 700 pages. Part I of the book covers general topics such as separation schemes (solvent extraction, precipitation, volatility, ion exchange), principles and instrumentation used for spectrophotometry, and color reagents in only 119 pages. Entire books have been written on each of those subjects. The author must therefore resort to extensive referencing to cover each subject adequately. Part II, Methods for Separation and Determination of Individual Elements, discusses all elements - both nonmetals and metals and major procedures for the separation and spectrophotometric determination of each element are adequately covered

  9. OPTIMIZING CONDITIONS FOR SPECTROPHOTOMETRIC DETERMINATION OF TOTAL POLYPHENOLS IN WINES USING FOLIN-CIOCALTEU REAGENT

    Directory of Open Access Journals (Sweden)

    Daniel Bajčan

    2013-02-01

    Full Text Available Wine is a complex beverage that obtains its properties mainly due to synergistic effect of alcohol, organic acids, arbohydrates, as well as the phenolic and aromatic substances. At present days, we can observe an increased interest in the study of polyphenols in wines that have antioxidant, antimicrobial, anti-inflammatory, anti-cancer and many other beneficial effects. Moderate and regular consumption of the red wine especially, with a high content of phenolic compounds, has a beneficial effect on human health. The aim of this work was to optimize conditions for spectrophotometric determination of total polyphenols in winwas to optimize conditions for spectrophotometric determination of total polyphenols in winwas to optimize conditions for spectrophotometric determination of total polyphenols in winwas to optimize conditions for pectrophotometric determination of total polyphenols in wine using Folin-Ciocaulteu reagent. Based on several studies, in order to minimize chemical use and optimize analysis time, we have proposed a method for the determination of total polyphenols using 0.25 ml Folin-Ciocaulteu reagent, 3 ml of 20% Na2CO3 solution and time of coloring complex 1.5 hour. We f

  10. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    International Nuclear Information System (INIS)

    Janot, N.; Benedetti, M. F.; Janot, N.; Reiller, P. E.; Korshin, G. V.

    2010-01-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM (≥1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  11. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Janot, N.; Benedetti, M. F. [Univ Paris Diderot, Lab Geochim Eaux, UMR CNRS 7154, IPGP, F-75025 Paris 13 (France); Janot, N.; Reiller, P. E. [CE Saclay, CEA DEN DANS DPC SECR, Lab Speciat Radionucleides and Mol, F-91191 Gif Sur Yvette (France); Korshin, G. V. [Univ Washington, Dept Civil and Environm Engn, Seattle, WA 98195 (United States)

    2010-07-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM ({>=}1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  12. Extractive Spectrophotometric Determination of Omeprazole in ...

    African Journals Online (AJOL)

    Erah

    Abstract. Purpose: To develop a simple, rapid and selective method for the extractive spectrophotometric determination of .... The colour intensity of the organic layer had shown a very .... considerable attention for quantitative analyses of many ...

  13. Spectrophotometric determination of eflornithine hydrochloride ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a spectrophotometric method for the quantitative determination of eflornithine hydrochloride as a pure compound and in pharmaceutical formulations. Methods: The method involved the reaction of the target compound with vanillin reagent at specific pH 5.6 to produce a green reddish color ...

  14. Spectrophotometric Determination of Eflornithine Hydrochloride ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a spectrophotometric method for the quantitative determination of eflornithine hydrochloride as a pure compound and in pharmaceutical formulations. Methods: The method involved the reaction of the target compound with vanillin reagent at specific pH. 5.6 to produce a green reddish color ...

  15. Extractive spectrophotometric determination of molybdenum using p-chloroisonitroso acetophenone hydrazone

    International Nuclear Information System (INIS)

    Lokhande, R.S.; Agashe, A.P.; Hundiwale, D.G.

    2001-01-01

    Separation technique like solvent extraction can be advantageously employed for the determination of metals at low concentration in micrograms using spectrophotometric methods. Hydrazoxine has been used for the extraction and spectrophotometric determination of metals at trace level as well as for the studies of transition metals in complex form. In the present paper, solvent extraction technique has been used to develop methods for the separation and spectrophotometric determination of Mo(VI) with p-chloroisonitroso acetophenone hydrazone was extracted into chloroform from aqueous solution in the pH range 8 to 8.5. The absorption maxima was also tried for the extracted species and Beer's law was also studied for its applicability. In this, interference from the foreign ion has also been examined. (author)

  16. SHARDS: a spectro-photometric analysis of distant red and dead massive galaxies

    Science.gov (United States)

    Pérez-González, P. G.; Cava, A.; The Shards Team

    2013-05-01

    SHARDS, an ESO/GTC Large Program, is an ultra-deep (26.5 mag) spectro-photometric survey carried out with GTC/OSIRIS and designed to select and study massive passively evolving galaxies at z= 1.0--2.5 in the GOODS-N field. The survey uses a set of 24 medium band filters (FWHM ˜15 nm) covering the 500--950 nm spectral range. Our observing strategy has been planned to detect, for z>1 sources, the prominent Mg absorption feature (at rest-frame ˜280 nm), a distinctive, necessary, and sufficient feature of evolved stellar populations (older than 0.5 Gyr). These observations are being used to: (1) construct for the first time an unbiased sample of high-z quiescent galaxies, which extends to fainter magnitudes the samples selected with color techniques and spectroscopic surveys; (2) derive accurate ages and stellar masses based on robust measurements of spectral features such as the Mg(UV) or D(4000) indices; (3) measure their redshift with an accuracy Δ z/(1+z)<0.02; and (4) study emission-line galaxies (starbursts and AGN) up to very high redshifts. The well-sampled optical SEDs provided by SHARDS for all sources in the GOODS-N field are a valuable complement for current and future surveys carried out with other telescopes (e.g., Spitzer, HST, and Herschel).

  17. Use of optical fibers in spectrophotometry

    Science.gov (United States)

    Ramsey, Lawrence W.

    1988-01-01

    The use of single or small numbers of fiber optic fibers in astronomical spectroscopy with the goal of greater spectrophotometric and radial velocity accuracy is discussed. The properties of multimode step index fibers which are most important for this application are outlined, as are laboratory tests of currently available fibers.

  18. Spectrophotometric measurement of calcium carbonate saturation states in seawater.

    Science.gov (United States)

    Easley, Regina A; Patsavas, Mark C; Byrne, Robert H; Liu, Xuewu; Feely, Richard A; Mathis, Jeremy T

    2013-02-05

    Measurements of ocean pH and carbonate ion concentrations in the North Pacific and Arctic Oceans were used to determine calcium carbonate saturation states (Ω(CaCO(3))) from spectrophotometric methods alone. Total carbonate ion concentrations, [CO(3)(2-)](T), were for the first time at sea directly measured using Pb(II) UV absorbance spectra. The basis of the method is given by the following: [formula see text] where (CO(3))β(1) is the PbCO(3)(0) formation constant, e(i) are molar absorptivity ratios, and R = (250)A/(234)A (ratio of absorbances measured at 250 and 234 nm). On the basis of shipboard and laboratory Pb(II) data and complementary carbon-system measurements, the experimental parameters were determined to be (25 °C) the following: [formula see text]. The resulting mean difference between the shipboard spectrophotometric and conventional determinations of [CO(3)(2-)](T) was ±2.03 μmol kg(-1). The shipboard analytical precision of the Pb(II) method was ∼1.71 μmol kg(-1) (2.28%). Spectrophotometric [CO(3)(2-)](T) and pH(T) were then combined to calculate Ω(CaCO(3)). For the case of aragonite, 95% of the spectrophotometric aragonite saturation states (Ω(Aspec)) were within ±0.06 of the conventionally calculated values (Ω(Acalc)) when 0.5 ≤ Ω(A) ≤ 2.0. When Ω(A) > 2.0, 95% of the Ω(Aspec) values were within ±0.18 of Ω(Acalc). Our shipboard experience indicates that spectrophotometric determinations of [CO(3)(2-)](T) and Ω(CaCO(3)) are straightforward, fast, and precise. The method yields high-quality measurements of two important, rapidly changing aspects of ocean chemistry and offers capabilities suitable for long-term automated in situ monitoring.

  19. The central pixel of the MAGIC telescope for optical observations

    Science.gov (United States)

    Lucarelli, F.; Barrio, J. A.; Antoranz, P.; Asensio, M.; Camara, M.; Contreras, J. L.; Fonseca, M. V.; Lopez, M.; Miranda, J. M.; Oya, I.; Reyes, R. De Los; Firpo, R.; Sidro, N.; Goebel, F.; Lorenz, E.; Otte, N.

    2008-05-01

    The MAGIC telescope has been designed for the observation of Cherenkov light generated in Extensive Air Showers initiated by cosmic particles. However, its 17 m diameter mirror and optical design makes the telescope suitable for direct optical observations as well. In this paper, we report about the development of a system based on the use of a dedicated photo-multiplier (PMT) for optical observations. This PMT is installed in the centre of the MAGIC camera (the so-called central pixel). An electro-to-optical system has been developed in order to transmit the PMT output signal by an optical fibre to the counting room, where it is digitized and stored for off-line analysis. The performance of the system using the optical pulsation of the Crab nebula as calibration source is presented. The time required for a 5σ detection of the Crab pulsar in the optical band is less than 20 s. The central pixel will be mainly used to perform simultaneous observations of the Crab pulsar both in the optical and γ-ray regimes. It will also allow for periodic testing of the precision of the MAGIC timing system using the Crab rotational optical pulses as a very precise timing reference.

  20. Second derivative spectrophotometric determination of ...

    African Journals Online (AJOL)

    A new, simple, rapid, wide applicable range and reliable second derivative spectrophotometric method has been developed for determination of cyclophosphamide (CP) in bulk and pharmaceutical dosage forms. Calibration graph is linear in the concentration range of 25 - 200 μg/ml of CP with 10 μg/ml of detection limit and ...

  1. Extraction spectrophotometric analyzer

    International Nuclear Information System (INIS)

    Batik, J.; Vitha, F.

    1985-01-01

    Automation is discussed of extraction spectrophotometric determination of uranium in a solution. Uranium is extracted from accompanying elements in an HCl medium with a solution of tributyl phosphate in benzene. The determination is performed by measuring absorbance at 655 nm in a single-phase ethanol-water-benzene-tributyl phosphate medium. The design is described of an analyzer consisting of an analytical unit and a control unit. The analyzer performance promises increased productivity of labour, improved operating and hygiene conditions, and mainly more accurate results of analyses. (J.C.)

  2. OBSERVATION OF CORRELATED OPTICAL AND GAMMA EMISSIONS FROM GRB 081126

    International Nuclear Information System (INIS)

    Klotz, A.; Boer, M.; Gendre, B.; Atteia, J. L.; Coward, D. M.; Imerito, A. C.

    2009-01-01

    We present an analysis of time-resolved optical emissions observed from the gamma-ray burst GRB 081126 during the prompt phase. The analysis employed time-resolved photometry using optical data obtained by the TAROT telescope, using BAT data from the Swift spacecraft, and time-resolved spectroscopy at high energies from the GBM instrument onboard the Fermi spacecraft. The optical emission of GRB 081126 is found to be compatible with the second gamma emission pulse shifted by a positive time lag of 8.4 ± 3.9 s. This is the first well-resolved observation of a time lag between optical and gamma emissions during a gamma-ray burst. Our observations could potentially provide new constraints on the fireball model for gamma-ray burst early emissions. Furthermore, observations of time lags between optical and gamma ray photons provides an exciting opportunity to constrain quantum gravity theories.

  3. Determination of loratadine in pharmaceuticals by a spectrophotometric method

    Directory of Open Access Journals (Sweden)

    Pavalache Georgeta

    2015-06-01

    Full Text Available The spectrophotometric method for determination of loratadine using tetraiodomercurate has been applied in various pharmaceutical formulations. The results confirmed that recovery value is optimum and the method is valid, thus it can be used in quality control and evaluation of loratadine tablets, oral formulations of mixed composition, oral solutions, etc. The method is easy and simple to apply, does not require complicated equipment and spectrophotometric reading time is reduced, which allows a large number of analyzes in a relatively short time.

  4. Kinetic spectrophotometric determination of some fluoroquinolone ...

    African Journals Online (AJOL)

    A simple and sensitive kinetic spectrophotometric method was developed for the determination of some fluoroquinolonea antibiotics; gemifloxacin mesylate, moxifloxacin hydrochloride and gatifloxacin in bulk and in pharmaceutical preparations. The method is based upon a kinetic investigation of the oxidation reaction of ...

  5. Spectrophotometric determination of the ASTM color of diesel oil

    Energy Technology Data Exchange (ETDEWEB)

    Douglas Willian Emanuel Alves Santana; Marcelle Prates Sepulveda; Paulo Jorge Sanches Barbeira

    2007-03-15

    One of the parameters analyzed to determine the quality of diesel oil is its ASTM color. Changes in color may be indicative of problems in the production process, contamination, degradation or the oxidation of diesel. The methodology recommended for determining the color of automotive diesel oil samples is the colorimetry according to standard ASTM D1500, in which a sample is introduced into a glass cell and the color of the sample is compared with an optical filter color scale. Although it is very simple, the manual method requires good visual acuity from the operator. This procedure becomes somewhat subjective in some cases since different operators can make distinct evaluations of the same sample. In this way, this work proposes the development of a spectrophotometric analysis methodology to eliminate the subjectiveness in the determination of ASTM color of diesel oil samples by using operator-independent parameters and making quality assay more accurate and precise. Short communication. 7 refs., 2 figs., 2 tabs.

  6. Spectrophotometric determination of nitrite in simulated Purex Process solutions

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, I.daC. de; Matsuda, H T; Araujo, B.F. de; Araujo, J.A. de

    1984-01-01

    A spectrophotometric method for nitrite determination in simulated Purex Process solutions is presented, utilizing the Griess reagent for the formation of the coloured azocompound with an absorption maximum at 525 nm. Molar absortivity was 36,262 and the sensitivity of the method 10/sup -6/M for nitrite. The calibration curve is linear in the range of 2 to 30..mu..g NO/sup -//sub 2//25 ml in cells of 1 cm optical path. The method can be used in the presence of uranium up to limits of an U/NO/sup -//sub 2/ ratio of 150. Test solutions were prepared to simulate composition and concentrations as obtained by irradiating standard fuel with a neutro flux of 3.2 x 10/sup 13/ n.s/sup -1/.cm/sup -2/, with a burn-up value of 33,000 Mwd/T and cooling time of two years. Nitrite determinations in these solutions were accurate within limits of 5%.

  7. Optical MEMS for Earth observation

    Science.gov (United States)

    Liotard, Arnaud; Viard, Thierry; Noell, Wilfried; Zamkotsian, Frédéric; Freire, Marco; Guldimann, Benedikt; Kraft, Stefan

    2017-11-01

    Due to the relatively large number of optical Earth Observation missions at ESA, this area is interesting for new space technology developments. In addition to their compactness, scalability and specific task customization, optical MEMS could generate new functions not available with current technologies and are thus candidates for the design of future space instruments. Most mature components for space applications are the digital mirror arrays, the micro-deformable mirrors, the programmable micro diffraction gratings and tiltable micromirrors. A first selection of market-pull and techno-push concepts is done. In addition, some concepts are coming from outside Earth Observation. Finally two concepts are more deeply analyzed. The first concept is a programmable slit for straylight control for space spectro-imagers. This instrument is a push-broom spectroimager for which some images cannot be exploited because of bright sources in the field-of-view. The proposed concept consists in replacing the current entrance spectrometer slit by an active row of micro-mirrors. The MEMS will permit to dynamically remove the bright sources and then to obtain a field-of-view with an optically enhanced signal-to-noise ratio. The second concept is a push-broom imager for which the acquired spectrum can be tuned by optical MEMS. This system is composed of two diffractive elements and a digital mirror array. The first diffractive element spreads the spectrum. A micromirror array is set at the location of the spectral focal plane. By putting the micro-mirrors ON or OFF, we can select parts of field-of-view or spectrum. The second diffractive element then recombines the light on a push-broom detector. Dichroics filters, strip filter, band-pass filter could be replaced by a unique instrument.

  8. New development of spectrophotometric analysis of thorium

    International Nuclear Information System (INIS)

    Yang Xiangzhen

    1992-01-01

    This review covers new development of spectrophotometric determination of thorium since 1980's. The methods include general spectrophotometry, double wavelength spectrophotometry, catalytic spectrophotometry, total differential spectrophotometry, derivative spectrophotometry and fluorescent spectrophotometry, etc

  9. Spectrophotometric determination of uranium using quercetin

    International Nuclear Information System (INIS)

    Barros, A.R.

    1972-10-01

    A spectrophotometric method for quantitative determination of uranium, using a flavone (quercetin) as complexing agent, is described. The method is based on the reaction between uranyl ion and alcoholic solution of quercetin with a complex formation of intense yellow color. (M.C.L.) [pt

  10. Spectrophotometric Determination Of Heavy Metals In Cosmetics

    African Journals Online (AJOL)

    ISSN 1597-6343. Spectrophotometric Determination Of Heavy Metals In Cosmetics ... analysed using atomic absorption spectrophotometer – coupled with a hydride ... presence of arsenic (As), mercury (Hg), cadmium (Cd) and lead. (Pb) in ...

  11. Optical Photometric Observations of GEO Debris

    Science.gov (United States)

    Seitzer, Patrick; Rodriquez-Cowardin, Heather M.; Barker, Edwin S.; Abercromby, Kira J.; Kelecy, Thomas M.; Horstman, Matt

    2010-01-01

    We report on a continuing program of optical photometric measurements of faint orbital debris at geosynchronous Earth orbit (GEO). These observations can be compared with laboratory studies of actual spacecraft materials in an effort to determine what the faint debris at GEO may be. We have optical observations from Cerro Tololo Inter-American Observatory (CTIO) in Chile of two samples of debris: 1. GEO objects discovered in a survey with the University of Michigan's 0.6-m aperture Curtis-Schmidt telescope MODEST (for Michigan Orbital DEbris Survey Telescope), and then followed up in real-time with the CTIO/SMARTS 0.9-m for orbits and photometry. Our goal is to determine 6 parameter orbits and measure colors for all objects fainter than R = 15 t11 magnitude that are discovered in the MODEST survey. 2. A smaller sample of high area to mass ratio (AMR) objects discovered independently, and acquired using predictions from orbits derived from independent tracking data collected days prior to the observations. Our optical observations in standard astronomical BVRI filters are done with either telescope, and with the telescope tracking the debris object at the object's angular rate. Observations in different filters are obtained sequentially. We have obtained 71 calibrated sequences of R-B-V-I-R magnitudes. A total of 66 of these sequences have 3 or more good measurements in all filters (not contaminated by star streaks or in Earth's shadow). Most of these sequences show brightness variations, but a small subset has observed brightness variations consistent with that expected from observational errors alone. The majority of these stable objects are redder than a solar color in both B-R and R-I. There is no dependence on color with brightness. For a smaller sample of objects we have observed with synchronized CCD cameras on the two telescopes. The CTIO 0.9-m observes in B, and MODEST in R. The CCD cameras are electronically linked together so that the start time and

  12. Computation of geometric representation of novel spectrophotometric methods used for the analysis of minor components in pharmaceutical preparations.

    Science.gov (United States)

    Lotfy, Hayam M; Saleh, Sarah S; Hassan, Nagiba Y; Salem, Hesham

    2015-01-01

    Novel spectrophotometric methods were applied for the determination of the minor component tetryzoline HCl (TZH) in its ternary mixture with ofloxacin (OFX) and prednisolone acetate (PA) in the ratio of (1:5:7.5), and in its binary mixture with sodium cromoglicate (SCG) in the ratio of (1:80). The novel spectrophotometric methods determined the minor component (TZH) successfully in the two selected mixtures by computing the geometrical relationship of either standard addition or subtraction. The novel spectrophotometric methods are: geometrical amplitude modulation (GAM), geometrical induced amplitude modulation (GIAM), ratio H-point standard addition method (RHPSAM) and compensated area under the curve (CAUC). The proposed methods were successfully applied for the determination of the minor component TZH below its concentration range. The methods were validated as per ICH guidelines where accuracy, repeatability, inter-day precision and robustness were found to be within the acceptable limits. The results obtained from the proposed methods were statistically compared with official ones where no significant difference was observed. No difference was observed between the obtained results when compared to the reported HPLC method, which proved that the developed methods could be alternative to HPLC techniques in quality control laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Development of Ultraviolet Spectrophotometric Method for Analysis ...

    African Journals Online (AJOL)

    HP

    Method for Analysis of Lornoxicam in Solid Dosage. Forms. Sunit Kumar Sahoo ... testing. Mean recovery was 100.82 % for tablets. Low values of % RSD indicate .... Saharty E, Refaat YS, Khateeb ME. Stability-. Indicating. Spectrophotometric.

  14. Challenges and solutions for the analysis of in situ, in crystallo micro-spectrophotometric data

    International Nuclear Information System (INIS)

    Dworkowski, Florian S. N.; Hough, Michael A.; Pompidor, Guillaume; Fuchs, Martin R.

    2015-01-01

    The particular challenge of the analysis of optical absorption and Raman spectroscopic data measured from protein crystals and how the SLS-APE software toolbox supports scientists in dealing with such data is described. Combining macromolecular crystallography with in crystallo micro-spectrophotometry yields valuable complementary information on the sample, including the redox states of metal cofactors, the identification of bound ligands and the onset and strength of undesired photochemistry, also known as radiation damage. However, the analysis and processing of the resulting data differs significantly from the approaches used for solution spectrophotometric data. The varying size and shape of the sample, together with the suboptimal sample environment, the lack of proper reference signals and the general influence of the X-ray beam on the sample have to be considered and carefully corrected for. In the present article, how to characterize and treat these sample-dependent artefacts in a reproducible manner is discussed and the SLS-APEin situ, in crystallo optical spectroscopy data-analysis toolbox is demonstrated

  15. Spectrophotometric determination of fluoride with alizarin complexone

    Energy Technology Data Exchange (ETDEWEB)

    Marczenko, Z; Lenarczyk, L [Politechnika Warszawska (Poland)

    1976-01-01

    The modification of direct spectrophotometric method of fluoride determination by alizarin complexone has been developed. It was shown that the lanthanum alizarin complexone chelate is more convenient than that of cerium (3). The influence of acetone, dioxane and dimethyl sulphoxide in water solution on the increase of sensitivity of the method and the rate of colour reaction has been determined. The optimal pH ranges for the reaction with lanthanum and cerium (3) have been estimated. Some amines having a large molecule are useful for extraction of blue fluoride complex with isobutanol. Dioctylamine was applied in a new extraction spectrophotometric procedure of fluoride determination. Conditions in reagent have been established. Both variants of the method have been applied to the fluoride determination in several chemicals. The obtained results show a good precision and accuracy.

  16. Optical observations of binary X-ray sources

    International Nuclear Information System (INIS)

    Charles, P.

    1982-01-01

    Here I shall consider only those systems where the compact object is a neutron star (or in a few cases perhaps a black hole). Since van Paradijs (1982) has recently produced an excellent and comprehensive review of optical observations of compact galactic X-ray sources I shall summarise the basic properties of the optical counterparts and discuss a few representative systems in some detail. (orig./WL)

  17. Optical observations geomagnetically conjugate to sprite-producing lightning discharges

    Directory of Open Access Journals (Sweden)

    R. A. Marshall

    2005-09-01

    Full Text Available Theoretical studies have predicted that large positive cloud-to-ground discharges can trigger a runaway avalanche process of relativistic electrons, forming a geomagnetically trapped electron beam. The beam may undergo pitch angle and energy scattering during its traverse of the Earth's magnetosphere, with a small percentage of electrons remaining in the loss cone and precipitating in the magnetically conjugate atmosphere. In particular, N2 1P and N2+1N optical emissions are expected to be observable. In July and August 2003, an attempt was made to detect these optical emissions, called "conjugate sprites", in correlation with sprite observations in Europe near . Sprite observations were made from the Observatoire du Pic du Midi (OMP in the French Pyrenées, and VLF receivers were installed in Europe to detect causative sferics and ionospheric disturbances associated with sprites. In the Southern Hemisphere conjugate region, the Wide-angle Array for Sprite Photometry (WASP was deployed at the South African Astronomical Observatory (SAAO, near Sutherland, South Africa, to observe optical emissions with a field-of-view magnetically conjugate to the Northern Hemisphere observing region. Observations at OMP revealed over 130 documented sprites, with WASP observations covering the conjugate region successfully for 30 of these events. However, no incidences of optical emissions in the conjugate hemisphere were found. Analysis of the conjugate optical data from SAAO, along with ELF energy measurements from Palmer Station, Antarctica, and charge-moment analysis, show that the lightning events during the course of this experiment likely had insufficient intensity to create a relativistic beam. Keywords. Ionosphere (Ionsophere-magnetosphere interactions; Ionospheric disturbances; Instruments and techniques

  18. IMPROVED SPECTROPHOTOMETRIC CALIBRATION OF THE SDSS-III BOSS QUASAR SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Margala, Daniel; Kirkby, David [Frederick Reines Hall, Department of Physics and Astronomy, University of California, Irvine, CA (United States); Dawson, Kyle [Department of Physics and Astronomy, University of Utah, Salt Lake City, UT 84112 (United States); Bailey, Stephen [Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, CA 94720 (United States); Blanton, Michael [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Schneider, Donald P., E-mail: dmargala@uci.edu [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States)

    2016-11-10

    We present a model for spectrophotometric calibration errors in observations of quasars from the third generation of the Sloan Digital Sky Survey Baryon Oscillation Spectroscopic Survey (BOSS) and describe the correction procedure we have developed and applied to this sample. Calibration errors are primarily due to atmospheric differential refraction and guiding offsets during each exposure. The corrections potentially reduce the systematics for any studies of BOSS quasars, including the measurement of baryon acoustic oscillations using the Ly α forest. Our model suggests that, on average, the observed quasar flux in BOSS is overestimated by ∼19% at 3600 Å and underestimated by ∼24% at 10,000 Å. Our corrections for the entire BOSS quasar sample are publicly available.

  19. Uranium fluorides analysis. Titanium spectrophotometric determination

    International Nuclear Information System (INIS)

    Anon.

    Titanium determination in uranium hexafluoride in the range 0.7 to 100 microgrammes after transformation of uranium fluoride in sulfate. Titanium is separated by extraction with N-benzoylphenylhydroxylamine, reextracted by hydrochloric-hydrofluoric acid. The complex titanium-N-benzoylphenylhydroxylamine is extracted by chloroform. Spectrophotometric determination at 400 nm [fr

  20. Optical and Near-infrared Study of Nova V2676 Oph 2012

    Energy Technology Data Exchange (ETDEWEB)

    Raj, A. [Korea Astronomy and Space Science Institute, Daejeon, 34055 (Korea, Republic of); Das, R. K. [Department of Astrophysics and Cosmology, S N Bose National Centre for Basic Sciences, Salt Lake, Kolkata 700106 (India); Walter, F. M., E-mail: ashish.raj@iiap.res.in [Department of Physics and Astronomy, Stony Brook University, Stony Brook, NY 11794-3800 (United States)

    2017-02-01

    We present optical spectrophotometric and near-infrared (NIR) photometric observations of the nova V2676 Oph covering the period from 2012 March 29 through 2015 May 8. The optical spectra and photometry of the nova have been taken from SMARTS and Asiago; the NIR photometry was obtained from SMARTS and Mt. Abu. The spectra were dominated by strong H i lines from the Balmer series, Fe ii, N i, and [O i] lines in the initial days, typical of an Fe ii type nova. The measured FWHM for the H β and H α lines was 800–1200 km s{sup −1}. There was pronounced dust formation starting 90 days after the outburst. The J − K color was the largest among recent dust-forming novae.

  1. Optical observations geomagnetically conjugate to sprite-producing lightning discharges

    Directory of Open Access Journals (Sweden)

    R. A. Marshall

    2005-09-01

    Full Text Available Theoretical studies have predicted that large positive cloud-to-ground discharges can trigger a runaway avalanche process of relativistic electrons, forming a geomagnetically trapped electron beam. The beam may undergo pitch angle and energy scattering during its traverse of the Earth's magnetosphere, with a small percentage of electrons remaining in the loss cone and precipitating in the magnetically conjugate atmosphere. In particular, N2 1P and N2+1N optical emissions are expected to be observable. In July and August 2003, an attempt was made to detect these optical emissions, called "conjugate sprites", in correlation with sprite observations in Europe near . Sprite observations were made from the Observatoire du Pic du Midi (OMP in the French Pyrenées, and VLF receivers were installed in Europe to detect causative sferics and ionospheric disturbances associated with sprites. In the Southern Hemisphere conjugate region, the Wide-angle Array for Sprite Photometry (WASP was deployed at the South African Astronomical Observatory (SAAO, near Sutherland, South Africa, to observe optical emissions with a field-of-view magnetically conjugate to the Northern Hemisphere observing region. Observations at OMP revealed over 130 documented sprites, with WASP observations covering the conjugate region successfully for 30 of these events. However, no incidences of optical emissions in the conjugate hemisphere were found. Analysis of the conjugate optical data from SAAO, along with ELF energy measurements from Palmer Station, Antarctica, and charge-moment analysis, show that the lightning events during the course of this experiment likely had insufficient intensity to create a relativistic beam.

    Keywords. Ionosphere (Ionsophere-magnetosphere interactions; Ionospheric disturbances; Instruments and techniques

  2. SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF MONTELUKAST SODIUM AND BAMBUTEROL HYDROCHLORIDE IN TABLETS

    OpenAIRE

    Patel Satish A; Patel Dhara J; Patel Natavarlal J.

    2011-01-01

    The present manuscript describe simple, sensitive, rapid, accurate, precise and economical first derivative spectrophotometric method for the simultaneous determination of montelukast sodium and bambuterol hydrochloride in combined tablet dosage form. The derivative spectrophotometric method was based on the determination of both the drugs at their respective zero crossing point (ZCP). The first order derivative spectra was obtained in chloroform and the determinations were made at 241 nm (ZC...

  3. Spectrophotometric determination of proteins associated with ...

    African Journals Online (AJOL)

    Twenty six Aeromonas isolates from fishes, poultry and humans in Zaria were quantified for total soluble proteins (enzymes) profiles in January, 2007 by spectrophotometric (Biuret) method. Isolates were grown on Brain Heart Infusion (BHI) broth, they were incubated at 370C and centrifuged at 1,000 g/dl using harous ...

  4. Optical MEMS for earth observation payloads

    Science.gov (United States)

    Rodrigues, B.; Lobb, D. R.; Freire, M.

    2017-11-01

    An ESA study has been taken by Lusospace Ltd and Surrey Satellite Techonoly Ltd (SSTL) into the use of optical Micro Eletro-Mechanical Systems (MEMS) for earth Observation. A review and analysis was undertaken of the Micro-Optical Electro-Mechanical Systems (MOEMS) available in the market with potential application in systems for Earth Observation. A summary of this review will be presented. Following the review two space-instrument design concepts were selected for more detailed analysis. The first was the use of a MEMS device to remove cloud from Earth images. The concept is potentially of interest for any mission using imaging spectrometers. A spectrometer concept was selected and detailed design aspects and benefits evaluated. The second concept developed uses MEMS devices to control the width of entrance slits of spectrometers, to provide variable spectral resolution. This paper will present a summary of the results of the study.

  5. Bi-static Optical Observations of GEO Objects

    Science.gov (United States)

    Seitzer, Patrick; Barker, Edwin S.; Cowardin, Heather; Lederer, Susan M.; Buckalew, Brent

    2014-01-01

    A bi-static study of objects at Geosynchronous Earth Orbit (GEO) was conducted using two ground-based wide-field optical telescopes. The University of Michigan's 0.6-m MODEST (Michigan Orbital Debris Survey Telescope) located at the Cerro Tololo Inter- American Observatory in Chile was employed in a series of coordinated observations with the U.S. Naval Observatory's (USNO) 1.3-m telescope at the USNO Flagstaff Station near Flagstaff, Arizona, USA. The goals of this project are twofold: (1) Obtain optical distances to known and unknown objects at GEO from the difference in the observed topocentric position of objects measured with respect to a reference star frame. The distance can be derived directly from these measurements, and is independent of any orbital solution. The wide geographical separation of these two telescopes means that the parallax difference is larger than ten degrees, and (2) Compare optical photometry in similar filters of GEO objects taken during the same time period from the two sites. The object's illuminated surfaces presented different angles of reflected sunlight to the two telescopes.During a four hour period on the night.of 22 February 2014 (UT), coordinated observations were obtained for eight different GEO positions. Each coordinated observation sequence was started on the hour or half-hour, and was selected to ensure the same cataloged GEO object was available in the field of view of both telescopes during the thirty minute observing sequence. GEO objects were chosen to be both controlled and uncontrolled at a range of orbital inclinations, and the objects were not tracked. Instead both telescopes were operated with all drives off in GEO survey mode to discover un-cataloged objects at GEO. The initial results from this proof-of-concept observing run will be presented, with the intent of laying the foundation for future large-scale bi-static observing campaigns of the GEO regime.

  6. SPECTROPHOTOMETRIC DETERMINATION OF NITRITE BY ITS ...

    African Journals Online (AJOL)

    Preferred Customer

    sources of nitrite include intensive use of chemical nitrogenous fertilizers, ... The current paper describes another kinetic spectrophotometric method for determination of ... s at λmax = 570 nm (allowing a lag time of 5 s) against water as reference. ... samples and the total amount of the analyte was estimated by applying the ...

  7. Spectrophotometric Determination of Cilostazol in Tablet Dosage Form

    African Journals Online (AJOL)

    Erah

    Purpose: To develop simple, rapid and selective spectrophotometric methods for ... Conclusion: These validated methods may be useful for routine analysis of cilostazol ... Keywords: Cilostazol tablets, UV spectrophotometry, Linear regression ...

  8. Validation of different spectrophotometric methods for determination of vildagliptin and metformin in binary mixture

    Science.gov (United States)

    Abdel-Ghany, Maha F.; Abdel-Aziz, Omar; Ayad, Miriam F.; Tadros, Mariam M.

    New, simple, specific, accurate, precise and reproducible spectrophotometric methods have been developed and subsequently validated for determination of vildagliptin (VLG) and metformin (MET) in binary mixture. Zero order spectrophotometric method was the first method used for determination of MET in the range of 2-12 μg mL-1 by measuring the absorbance at 237.6 nm. The second method was derivative spectrophotometric technique; utilized for determination of MET at 247.4 nm, in the range of 1-12 μg mL-1. Derivative ratio spectrophotometric method was the third technique; used for determination of VLG in the range of 4-24 μg mL-1 at 265.8 nm. Fourth and fifth methods adopted for determination of VLG in the range of 4-24 μg mL-1; were ratio subtraction and mean centering spectrophotometric methods, respectively. All the results were statistically compared with the reported methods, using one-way analysis of variance (ANOVA). The developed methods were satisfactorily applied to analysis of the investigated drugs and proved to be specific and accurate for quality control of them in pharmaceutical dosage forms.

  9. Spectrophotometric reading of EUCAST antifungal susceptibility testing of Aspergillus fumigatus

    DEFF Research Database (Denmark)

    Meletiadis, J.; Leth Mortensen, K.; Verweij, P. E.

    2017-01-01

    with spectrophotometrically determined MICs and essential (±1 twofold dilution) and categorical (susceptible/intermediate/resistant or wild-type/non-wild-type) agreement was calculated. Spectrophotometric data were analysed with regression analysis using the Emax model, and the effective concentration corresponding to 5% (EC......5) was estimated. Results Using the 5% cut-off, high essential (92%–97%) and categorical (93%–99%) agreement (

  10. Study on the Solid Phase Extraction and Spectrophotometric ...

    African Journals Online (AJOL)

    NJD

    Spectrophotometric Determination of Mercury in Water and. Biological ... 1Department of Chemistry, Yunnan University, Kunming, 650091, P.R. China. 2Department of ... (such as higher enrichment factor, reduced contamination of the.

  11. PCA-based algorithm for calibration of spectrophotometric analysers of food

    International Nuclear Information System (INIS)

    Morawski, Roman Z; Miekina, Andrzej

    2013-01-01

    Spectrophotometric analysers of food, being instruments for determination of the composition of food products and ingredients, are today of growing importance for food industry, as well as for food distributors and consumers. Their metrological performance significantly depends of the numerical performance of available means for spectrophotometric data processing; in particular – the means for calibration of analysers. In this paper, a new algorithm for this purpose is proposed, viz. the algorithm using principal components analysis (PCA). It is almost as efficient as PLS-based algorithms of calibration, but much simpler

  12. Development of an indirect spectrophotometric method for ...

    African Journals Online (AJOL)

    A simple and rapid indirect spectrophotometric method for determination of ... of the colored product was measured at 405 nm and pH 3 against a reagent blank. ... The limit of detection and quantification were found to be 0.20±0.03 and ...

  13. Fiber optic spectrophotometer with photodiode linear array

    International Nuclear Information System (INIS)

    Blanc, F.; Vernet, P.

    1988-01-01

    Spectrophotometric measurements are used in a great number of industrial processes, in nuclear environment and with optical precision components. Especially the evolution of a chemical process or of an optical coating could be followed by these measurements. Spectrophotometers, using optical fibers to transport the signal out of the instrument make possible the measurement ''in-situ'' and in real time. The advantage of using a diode array to detect the signal is an instantaneous measurement all over the spectral range without moving parts. It allows an excellent reproductibility. The instrument is controlled by a micro computer. The spectrophotometer is described and technical performance presented. An extension using optical fibers on a ''classical'' spectrophotometer (a H.P. one) is also described and technical performance presented

  14. Spectrophotometric Determination of Nitrate in Vegetables Using ...

    African Journals Online (AJOL)

    DR. MIKE HORSFALL

    ABSTRACT: A rapid and sensitive spectrophotometric method for the determination of nitrate in vegetables is described. The method is based on the measurement of the absorbance of yellow sodium nitrophenoxide formed via the reaction of phenol with the vegetable-based nitrate in presence of sulphuric acid.

  15. Spectrophotometric Methods for the Determination of Ketoconazole ...

    African Journals Online (AJOL)

    Spectrophotometric Methods for the Determination of Ketoconazole in Pharmaceutical Dosage Forms. ... Tropical Journal of Pharmaceutical Research ... Methods: The first method (A) was based on the oxidation of the studied drug by a known excess of cerium (IV) as an oxidizing agent and subsequent determination of ...

  16. Spectrophotometric Determination of Trimipramine in Tablet Dosage ...

    African Journals Online (AJOL)

    Purpose: To develop and validate simple, rapid and sensitive spectrophotometric procedures for determination of trimipramine in tablet dosage form. Methods: The methods were based on the interaction of trimipramine as n-electron donor with the ο-acceptor, iodine and various π-acceptors, namely: chloranil (CH), ...

  17. Optical fiber couplers for spectrophotometry. Perspectives for in-situ on-line and remote measurements

    International Nuclear Information System (INIS)

    Boisde, G.; Linger, C.; Chevalier, G.; Perez, J.J.

    1983-01-01

    Optical fiber couplers have been developed specially for nuclear chemical spectrophotometric applications. Coupling devices are described for TELEPHOT industrial photometers and some commercial spectrophotometer, together with the probes and measurement cells employed. The value of optical multiplexing is mentioned. Non nuclear applications in medical analysis are also mentioned, together with the possibilities offered by these devices for uses other than spectrophotometry [fr

  18. Spectrophotometric and Voltammetric Studies on the Interaction of ...

    African Journals Online (AJOL)

    0.84V(vs. SCE) also changed correspondingly without change of the peak potential, which also indicated that the binding reaction had taken place. Under the selected conditions a new spectrophotometric analytical method was established for ...

  19. Development and Application of Kinetic Spectrophotometric Method ...

    African Journals Online (AJOL)

    Purpose: To develop an improved kinetic-spectrophotometric procedure for the determination of metronidazole (MNZ) in pharmaceutical formulations. Methods: The method is based on oxidation reaction of MNZ by hydrogen peroxide in the presence of Fe(II) ions at pH 4.5 (acetate buffer). The reaction was monitored ...

  20. Titrimetric and Spectrophotometric Determination of Metaprolol tartrate in Pharmaceuticals Using N-Bromosuccinimide

    OpenAIRE

    K. Basavaiah; B. C. Somashekar

    2007-01-01

    One titrimetric and two spectrophotometric methods are presented for the assay of metaprolol tartrate (MPT) in bulk drug and in tablets. The methods employ N-bromosuccinimide (NBS) as the oxidimetric reagent and two dyes, methyl orange and indigo carmine as spectrophotometric reagents. In titrimetry, an acidified solution of MPT is treated with a known excess amount of NBS and after a definite time, the unreacted oxidant is determined by iodometric back titration. Spectrophotometry involve...

  1. Development and Validation of Spectrophotometric Methods for the Determination of Rasagiline in Pharmaceutical Preparations

    Directory of Open Access Journals (Sweden)

    Serife Evrim Kepekci Tekkeli

    2013-01-01

    Full Text Available This study presents three simple, rapid, and accurate spectrophotometric methods for the determination of Rasagiline (RSG in pharmaceutical preparations. The determination procedures depend on the reaction of RSG with chloranilic acid for method A, tetrachloro-1,4-benzoquinone for method B, and 7,7,8,8-tetracyanoquinodimethane for method C. The colored products were quantitated spectrophotometrically at 524, 535, and 843 nm for methods A, B, and C, respectively. Different variables affecting the reaction were optimized. Linearity ranges of the methods with good correlation coefficients (0.9988–0.9996 were observed as 25–300 µg mL−1, 25–350 µg mL−1, and 50–500 µg mL−1 for methods A, B, and C, respectively. The formation of products takes place through different mechanisms. The sites of interaction were confirmed by elemental analysis using IR and 1H-NMR spectroscopy. The validation of the methods was carried out in terms of specificity, linearity, accuracy, precision, robustness, limit of detection, and limit of quantitation. No interference was observed from concomitants usually present in dosage forms. The methods were applied successfully to the determination of RSG in pharmaceutical preparations.

  2. Observation of three dimensional optical rogue waves through obstacles

    International Nuclear Information System (INIS)

    Leonetti, Marco; Conti, Claudio

    2015-01-01

    We observe three-dimensional rogue waves in the speckle distribution of a spatially modulated optical beam. Light is transmitted beyond a partially reflecting obstacle generating optical rogue waves at a controlled position in the shadow of the barrier. When the barrier transmits only 0.07% of the input laser power, we observe the mostly localized event. These results demonstrate that an optimum amount of spatial non-homogeneity maximizes the probability of a gigantic event while the technique we exploit enables to control light behind a fully reflective wall

  3. Spectrophotometric study of Saturn's main rings by means of Monte Carlo ray-tracing and Hapke's theory

    Science.gov (United States)

    Ciarniello, Mauro; Filacchione, Gianrico; D'Aversa, Emiliano; Cuzzi, Jeffrey N.; Capaccioni, Fabrizio; Hedman, Matthew M.; Dalle Ore, Cristina M.; Nicholson, Philip D.; Clark, Roger Nelson; Brown, Robert H.; Cerroni, Priscilla; Spilker, Linda

    2017-10-01

    This work is devoted to the investigation of the spectrophotometric properties of Saturn's rings from Cassini-VIMS (Visible and Infrared Mapping Spectrometer) observations. The dataset used for this analysis is represented by ten radial spectrograms of the rings which have been derived in Filacchione et al. (2014) by radial mosaics produced by VIMS. Spectrograms report the measured radiance factor of the main Saturn's rings as a function of both radial distance (from 73.500 to 141.375 km) and wavelength (0.35-5.1 µm) for different observation geometries (phase angle ranging in the 1.9°-132.2° interval). We take advantage of a Monte Carlo ray-tracing routine to characterize the photometric behavior of the rings at each wavelength and derive the spectral Bond albedo of rings particles. This quantity is used to infer the composition of the regolith covering rings particles by applying Hapke's theory. Four different regions, characterized by different optical depths, and respectively located in the C ring, inner B ring, mid B ring and A ring, have been investigated. Results from spectral modeling indicate that rings spectrum can be described by water ice with minimal inclusion of organic materials (tholin, exogenous material, which is more effective in the less dense regions of the rings because of their lower content of pure water ice.

  4. Spectrophotometric Determination of Cilostazol in Tablet Dosage Form

    African Journals Online (AJOL)

    Purpose: To develop simple, rapid and selective spectrophotometric methods for the determination of cilostazol in tablet dosage form. Methods: Cilostazol was dissolved in 50 % methanol and its absorbance was scanned by ultraviolet (UV) spectrophotometry. Both linear regression equation and standard absorptivity were ...

  5. Spectrophotometric determination of copper with ascorbic acid

    International Nuclear Information System (INIS)

    Majeed, A.; Mustafa, M.M.; Asma, R.N.; Sareecha, N.

    1996-01-01

    Copper has been determined spectrophotometrically by using ascorbic acid as a chromagenic reagent. The complex formed in basic medium is measured for its absorbance at 340 n.m. Interference for 23 cations and 9 anions has also been checked. Effect of pH, time, temperature, ammonia, reagent concentration and interferents has been report. (author)

  6. Spectrophotometric determination of copper with ascorbic acid

    Energy Technology Data Exchange (ETDEWEB)

    Majeed, A; Mustafa, M M; Asma, R N; Sareecha, N [Islamia Univ., Bahawalpur (Pakistan). Chemistry Dept.

    1996-06-01

    Copper has been determined spectrophotometrically by using ascorbic acid as a chromagenic reagent. The complex formed in basic medium is measured for its absorbance at 340 n.m. Interference for 23 cations and 9 anions has also been checked. Effect of pH, time, temperature, ammonia, reagent concentration and interferents has been report. (author).

  7. Spectrophotometric titrations: Application to the determination of some elements in uranium solutions

    International Nuclear Information System (INIS)

    L'Her, M.

    1967-01-01

    The aim of this work is the application of spectrophotometric titrations to the analysis of uranium-containing solutions. We have been led to examine the general principles involved in these titrations, and we give a brief outline of these principles. In the first part we deal therefore with spectrophotometric titrations from a general point of view, examining their fundamental principle, their practical execution as well as the various possibilities of the method. The advantage of the titration are examined, in particular that of lending itself simultaneous determination of two species. The possibility of applying these spectrophotometric titrations to the analysis of uranium-containing solutions is the subject of the second part of this report: the dosage of a few species in uranium (VI) solutions is described. To this second part is added an experimental appendix consisting of a description of the apparatus, as well as of the operational techniques used for certain titrations, in particular those involving solutions containing uranium. (author) [fr

  8. Spectrophotometric titration of sulfates in the presence of zirconium

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Kotova, S.S.; Molokanova, L.G.; Chekmarev, A.M.; Yagodin, G.A.

    1978-01-01

    The procedure has been proposed for express determination of sulphate ions in the presence of zirconium by spectrophotometric titration with the use of barium chloride and nitrochromazo as an indicator. The procedure is based on bonding zirconium into a more stable complex with EDTA (ethylenediaminotetraacetic acid). The presence of excess of EDTA and zirconium (4) complexonate in the solution being titrated does not affect the titration curve shape and the character of break on the curve in the equivalence point. A complete demasking of SO 4 2- is observed in the case of 1O-fold excess of EDTA with respect to zirconium (4). Statistic evaluation of the method has shown that the results of titration can be distorted by chance errors only

  9. The cloud radiation impact from optics simulation and airborne observation

    Science.gov (United States)

    Melnikova, Irina; Kuznetsov, Anatoly; Gatebe, Charles

    2017-02-01

    The analytical approach of inverse asymptotic formulas of the radiative transfer theory is used for solving inverse problems of cloud optics. The method has advantages because it does not impose strict constraints, but it is tied to the desired solution. Observations are accomplished in extended stratus cloudiness, above a homogeneous ocean surface. Data from NASA`s Cloud Absorption Radiometer (CAR) during two airborne experiments (SAFARI-2000 and ARCTAS-2008) were analyzed. The analytical method of inverse asymptotic formulas was used to retrieve cloud optical parameters (optical thickness, single scattering albedo and asymmetry parameter of the phase function) and ground albedo in all 8 spectral channels independently. The method is free from a priori restrictions and there is no links to parameters, and it has been applied to data set of different origin and geometry of observations. Results obtained from different airborne, satellite and ground radiative experiments appeared consistence and showed common features of values of cloud parameters and its spectral dependence (Vasiluev, Melnikova, 2004; Gatebe et al., 2014). Optical parameters, retrieved here, are used for calculation of radiative divergence, reflected and transmitted irradiance and heating rates in cloudy atmosphere, that agree with previous observational data.

  10. Determination of U and Impurities Elements in The Uranium Tetra Fluoride by Potentiometric and Atomic Absorption Spectrophotometric Methods

    International Nuclear Information System (INIS)

    Putro Kasino, P

    1998-01-01

    The determination of u and impurities contents in the Uranium tetra fluoride (UF 4 )has been carried out by potentiometric titration using modified 'Davies-Gray' and atomic absorption spectrophotometric methods. Dissolution process of the powder sample using saturated Al 2 (SO 4 ) 3 solution introduced to determine UF 4 compound content in the UF 4 sample. The uranium Content in the obtained filtrate is analyzed by potentiometric. The impurities content is determined by ato-Mic absorption spectrophotometric using ammonium oxalate powder in introducing of the sample preparation. The experiment covered the observation on influence of stirring time of UF 4 sample dissolution in respect to separate UF 4 from its impurities in determination of uranium content. Also the effects of Ammonium Oxalate added and agitating time were observed deal with the sample preparation for the determination of Impurities content.The analysis result found that UF 4 content was 96.15 ± 0.04% the relative station 0.7%. However the best impurities determination was achieved by addition of ammonium oxalate powder and 15 Minutes of agitation time at temperature of 800 0 C

  11. Spectro-photometric determinations of Mn, Fe and Cu in aluminum master alloys

    Science.gov (United States)

    Rehan; Naveed, A.; Shan, A.; Afzal, M.; Saleem, J.; Noshad, M. A.

    2016-08-01

    Highly reliable, fast and cost effective Spectro-photometric methods have been developed for the determination of Mn, Fe & Cu in aluminum master alloys, based on the development of calibration curves being prepared via laboratory standards. The calibration curves are designed so as to induce maximum sensitivity and minimum instrumental error (Mn 1mg/100ml-2mg/100ml, Fe 0.01mg/100ml-0.2mg/100ml and Cu 2mg/100ml-10mg/ 100ml). The developed Spectro-photometric methods produce accurate results while analyzing Mn, Fe and Cu in certified reference materials. Particularly, these methods are suitable for all types of Al-Mn, Al-Fe and Al-Cu master alloys (5%, 10%, 50% etc. master alloys).Moreover, the sampling practices suggested herein include a reasonable amount of analytical sample, which truly represent the whole lot of a particular master alloy. Successive dilution technique was utilized to meet the calibration curve range. Furthermore, the workout methods were also found suitable for the analysis of said elements in ordinary aluminum alloys. However, it was observed that Cush owed a considerable interference with Fe, the later one may not be accurately measured in the presence of Cu greater than 0.01 %.

  12. [Morphological observation on hypopus of Lepidoglyphus destructor by optical microscope].

    Science.gov (United States)

    Yong, H; Ning, T; Qiang, C; Chao-Pin, L I

    2017-07-03

    Objective To observe the external morphology of Lepidoglyphus destructor hypopus under an optical microscope. Methods The samples were collected in a store of Chinese medicinal herbs in Huainan City in September, 2016, the L. destructor and the hypopus were isolated, and then made of slide specimens. The slide samples were prepared and observed under an optical microscope. Results The L. destructor hypopus and protonymph were found. The inactive hypopus was oval in shape, the feet were not welldeveloped, there was a distinct transverse seam on its back, and there were 2 pairs of genital sensory organs. Conclusion The optical microscopy shows the morphological characteristics of L. destructor hypopus, which can provide the basis for the biological classification and the prevention.

  13. Irradiation behavior of developed radiation resistance optical-fibers and observed optical radiation from their SiO2 cores under reactor irradiation

    International Nuclear Information System (INIS)

    Shikama, Tatsuo; Narui, Minoru; Kayano, Hideo; Kakuta, Tsunemi; Sagawa, Tsutomu; Sanada, Kazuo; Shamoto, Naoki; Uramoto, Toshimasa.

    1994-01-01

    Two kinds of optical fibers were irradiated in a fission reactor, JMTR(Japan Materials Testing Reactor), up to a 1.55x10 19 n/cm 2 fast neutron fluence and a 3.3x10 9 Gy ionizing dose at 370K. Optical transmission spectra were measured in the wavelength range of 450-1750nm, in-situ. Growth of strong optical absorption bands were observed in the range of wavelength shorter than 750nm. In the meantime, the fibers showed good radiation-resistance in the range of wavelength longer than 750nm. Optical radiations were observed from SiO 2 optical fibers under irradiation. A major part of the observed optical radiations is thought to be composed of broad optical radiation in the whole wavelength range studied in the present experiment. This broad optical radiation will be generated by the process of so-called Cerenkov radiation. Also, a sharp optical radiation peak was found at 1270nm on a F-doped fiber. This peak is thought to relate with doped Fluorine ions and ionizing gamma-ray irradiation. (author)

  14. Spectrophotometric determination of pizotefin maleate in pure form ...

    African Journals Online (AJOL)

    Two simple, quick and sensitive methods were described for the spectrophotometric determination of pizotefin maleate (PZT) either in pure form or pharmaceutical form (tablets). The methods were based on the reaction of pizotefin maleate as 'n' electron donor with chloranilic acid (p-CLA) and 7,7,8 ...

  15. Extraction-spectrophotometric method for silicon determination in high-purity substances. 1. Silicon determination in tellurium

    Energy Technology Data Exchange (ETDEWEB)

    Shaburova, V P; Yudelevich, I G [AN SSSR, Novosibirsk (USSR). Inst. Neorganicheskoj Khimii

    1989-01-01

    The extraction-spectrophotometric method for silicon determination in tellurium based on extraction isolation of the base by tributyl phosphate from hydrochloride solutions and with addition of HNO/sub 3/ and spectrophotometric silicon determination using malachite green is developed. The method permits to determine 2x10/sup -1/-3x10/sup -4/ % Si.

  16. Deep optical observations of the γ-ray pulsar J0357+3205

    Science.gov (United States)

    Kirichenko, A.; Danilenko, A.; Shibanov, Yu.; Shternin, P.; Zharikov, S.; Zyuzin, D.

    2014-04-01

    Context. A middle-aged radio-quiet pulsar J0357+3205 was discovered in gamma rays with Fermi and later in X-rays with Chandra and XMM-Newton observatories. It produces an unusual thermally emitting pulsar wind nebula that is observed in X-rays. Aims: Deep optical observations were obtained to search for the pulsar optical counterpart and its nebula using the Gran Telescopio Canarias (GTC). Methods: The direct imaging mode in the Sloan g' band was used. Archival X-ray data were reanalysed and compared with the optical data. Results: No pulsar optical counterpart was detected down to g'≥slant 28.1m. No pulsar nebula was identified in the optical either. We confirm early results that the X-ray spectrum of the pulsar consists of a nonthermal power-law component of the pulsar magnetospheric origin dominating at high energies and a soft thermal component from the neutron star surface. Using magnetised, partially ionised hydrogen atmosphere models in X-ray spectral fits, we found that the thermal component can come from the entire surface of the cooling neutron star with a temperature of 36+8-6 eV, making it one of the coldest among cooling neutron stars known. The surface temperature agrees with the standard neutron star cooling scenario. The optical upper limit does not put any additional constraints on the thermal component, however it does imply a strong spectral break for the nonthermal component between the optical and X-rays as is observed in other middle-aged pulsars. Conclusions: The thermal emission from the entire surface of the neutron star very likely dominates the nonthermal emission in the UV range. Observations of PSR J0357+3205 in this range are promising to put more stringent constraints on its thermal properties. Based on observations made with the Gran Telescopio Canarias (GTC), instaled in the Spanish Observatorio del Roque de los Muchachos of the Instituto de Astrofísica de Canarias, in the island of La Palma under Programme GTC3-12BMEX

  17. Building-up a database of spectro-photometric standards from the UV to the NIR

    Science.gov (United States)

    Vernet, J.; Kerber, F.; Mainieri, V.; Rauch, T.; Saitta, F.; D'Odorico, S.; Bohlin, R.; Ivanov, V.; Lidman, C.; Mason, E.; Smette, A.; Walsh, J.; Fosbury, R.; Goldoni, P.; Groot, P.; Hammer, F.; Kaper, L.; Horrobin, M.; Kjaergaard-Rasmussen, P.; Royer, F.

    2010-11-01

    We present results of a project aimed at establishing a set of 12 spectro-photometric standards over a wide wavelength range from 320 to 2500 nm. Currently no such set of standard stars covering the near-IR is available. Our strategy is to extend the useful range of existing well-established optical flux standards (Oke 1990, Hamuy et al. 1992, 1994) into the near-IR by means of integral field spectroscopy with SINFONI at the VLT combined with state-of-the-art white dwarf stellar atmospheric models (TMAP, Holberg et al. 2008). As a solid reference, we use two primary HST standard white dwarfs GD71 and GD153 and one HST secondary standard BD+17 4708. The data were collected through an ESO “Observatory Programme” over ~40 nights between February 2007 and September 2008.

  18. Yonsei Evolutionary Population Synthesis (YEPS). II. Spectro-photometric Evolution of Helium-enhanced Stellar Populations

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chul; Yoon, Suk-Jin; Lee, Young-Wook, E-mail: chulchung@yonsei.ac.kr, E-mail: sjyoon0691@yonsei.ac.kr [Center for Galaxy Evolution Research, Yonsei University, Seoul 03722 (Korea, Republic of)

    2017-06-20

    The discovery of multiple stellar populations in Milky Way globular clusters (GCs) has stimulated various follow-up studies on helium-enhanced stellar populations. Here we present the evolutionary population synthesis models for the spectro-photometric evolution of simple stellar populations (SSPs) with varying initial helium abundance ( Y {sub ini}). We show that Y {sub ini} brings about dramatic changes in spectro-photometric properties of SSPs. Like the normal-helium SSPs, the integrated spectro-photometric evolution of helium-enhanced SSPs is also dependent on metallicity and age for a given Y {sub ini}. We discuss the implications and prospects for the helium-enhanced populations in relation to the second-generation populations found in the Milky Way GCs. All of the models are available at http://web.yonsei.ac.kr/cosmic/data/YEPS.htm.

  19. Yonsei Evolutionary Population Synthesis (YEPS). II. Spectro-photometric Evolution of Helium-enhanced Stellar Populations

    International Nuclear Information System (INIS)

    Chung, Chul; Yoon, Suk-Jin; Lee, Young-Wook

    2017-01-01

    The discovery of multiple stellar populations in Milky Way globular clusters (GCs) has stimulated various follow-up studies on helium-enhanced stellar populations. Here we present the evolutionary population synthesis models for the spectro-photometric evolution of simple stellar populations (SSPs) with varying initial helium abundance ( Y ini ). We show that Y ini brings about dramatic changes in spectro-photometric properties of SSPs. Like the normal-helium SSPs, the integrated spectro-photometric evolution of helium-enhanced SSPs is also dependent on metallicity and age for a given Y ini . We discuss the implications and prospects for the helium-enhanced populations in relation to the second-generation populations found in the Milky Way GCs. All of the models are available at http://web.yonsei.ac.kr/cosmic/data/YEPS.htm.

  20. Method development for arsenic analysis by modification in spectrophotometric technique

    Directory of Open Access Journals (Sweden)

    M. A. Tahir

    2012-01-01

    Full Text Available Arsenic is a non-metallic constituent, present naturally in groundwater due to some minerals and rocks. Arsenic is not geologically uncommon and occurs in natural water as arsenate and arsenite. Additionally, arsenic may occur from industrial discharges or insecticide application. World Health Organization (WHO and Pakistan Standard Quality Control Authority have recommended a permissible limit of 10 ppb for arsenic in drinking water. Arsenic at lower concentrations can be determined in water by using high tech instruments like the Atomic Absorption Spectrometer (hydride generation. Because arsenic concentration at low limits of 1 ppb can not be determined easily with simple spectrophotometric technique, the spectrophotometric technique using silver diethyldithiocarbamate was modified to achieve better results, up to the extent of 1 ppb arsenic concentration.

  1. Spectrophotometric and Refractometric Determination of Total Protein in Avian Plasma

    Directory of Open Access Journals (Sweden)

    Rodica Căpriță

    2013-10-01

    Full Text Available The aim of this study was to compare the total protein values obtained in heparin plasma of chickens by a spectrophotometric technique (biuret method, and the values obtained on the same day in the same samples by refractometry. The results obtained by refractometry (average value 2.638±0.153g% were higher than those obtained by the spectrophotometric method (average value 2.441±0.181g%. There was a low correlation (r = 0.6709 between the total protein values, determined with both methods. Protein is the major determinant of plasma refractive index, but glucose contributes too. The refractometric method is not recommended in chickens for the determination of total protein, because avian blood glucose concentration averages about twice than in mammalian blood.

  2. Spectrophotometric and theoretical studies on the determination of ...

    African Journals Online (AJOL)

    Purpose: To develop a simple and cost effective spectrophotometric method for the ... species exhibited absorption maxima at 410 and 479 nm for the two systems in ... etilefrine in plasma and urine in pharmacokinetic ... In this work, the interactions of ET with BCG and ... prepared where the total volume of investigated.

  3. Observation and analysis of water inherent optical properties

    Science.gov (United States)

    Sun, Deyong; Li, Yunmei; Le, Chengfeng; Huang, Changchun

    2008-03-01

    Inherent optical property is an important part of water optical properties, and is the foundation of water color analytical model establishment. Through quantity filter technology (QFT) and backscattering meter BB9 (WETlabs Inc), absorption coefficients of CDOM, total suspended minerals and backscattering coefficients of total suspended minerals had been observed in Meiliang Bay of Taihu lake at summer and winter respectively. After analyzing the spectral characteristics of absorption and backscattering coefficients, the differences between two seasons had been illustrated adequately, and the reasons for the phenomena, which are related to the changes of water quality coefficient, had also been explained. So water environment states can be reflected by inherent optical properties. In addition, the relationship models between backscattering coefficients and suspended particle concentrations had been established, which can support coefficients for analytical models.

  4. Coincident Observation of Lightning using Spaceborne Spectrophotometer and Ground-Level Electromagnetic Sensors

    Science.gov (United States)

    Adachi, Toru; Cohen, Morris; Li, Jingbo; Cummer, Steve; Blakeslee, Richard; Marshall, THomas; Stolzenberg, Maribeth; Karunarathne, Sumedhe; Hsu, Rue-Ron; Su, Han-Tzong; hide

    2012-01-01

    The present study aims at assessing a possible new way to reveal the properties of lightning flash, using spectrophotometric data obtained by FORMOSAT-2/ISUAL which is the first spaceborne multicolor lightning detector. The ISUAL data was analyzed in conjunction with ground ]based electromagnetic data obtained by Duke magnetic field sensors, NLDN, North Alabama Lightning Mapping Array (LMA), and Kennedy Space Center (KSC) electric field antennas. We first classified the observed events into cloud ]to ]ground (CG) and intra ]cloud (IC) lightning based on the Duke and NLDN measurements and analyzed ISUAL data to clarify their optical characteristics. It was found that the ISUAL optical waveform of CG lightning was strongly correlated with the current moment waveform, suggesting that it is possible to evaluate the electrical properties of lightning from satellite optical measurement to some extent. The ISUAL data also indicated that the color of CG lightning turned to red at the time of return stroke while the color of IC pulses remained unchanged. Furthermore, in one CG event which was simultaneously detected by ISUAL and LMA, the observed optical emissions slowly turned red as the altitude of optical source gradually decreased. All of these results indicate that the color of lightning flash depends on the source altitude and suggest that spaceborne optical measurement could be a new tool to discriminate CG and IC lightning. In the presentation, we will also show results on the comparison between the ISUAL and KSC electric field data to clarify characteristics of each lightning process such as preliminary breakdown, return stroke, and subsequent upward illumination.

  5. Design of Rose Bengal/FTO optical thin film system as a novel nonlinear media for infrared blocking windows

    Directory of Open Access Journals (Sweden)

    S.M. El-Bashir

    Full Text Available Rose Bengal (RB is a new organic semiconductor with the highly stable layer, was deposited on highly cleaned conductive glass substrate known as (FTO glass with different thickness in the range from 80 to 292 nm. XRD showed an entirely amorphous structure of the studied film thicknesses. The observed peaks are the indexed peaks for FTO layer. Spectrophotometric data as transmittance, reflectance, and absorbance were used for the analysis the optical constant of RB/FTO optical thin film system. Refractive index was calculated using Fresnel’s equation with the aid of reflectance and absorption index. The dielectric constant, dielectric loss and dissipation factor were discussed and analyzed according to the applied optical theories. Nonlinear parameters such as third order nonlinear optical susceptibility and the nonlinear refractive index were calculated based on the linear refractive index of the applications of this material in nonlinear media. The results showed that Rose Bengal is a proving material for wide scale optoelectronic applications such as infrared blocking windows. Keywords: Rose Bengal, Dielectric parameters, Linear/nonlinear optics, Dye/FTO, IR blocking windows

  6. [Spectrophotometric and HPLC evaluation of ceftazidime stability].

    Science.gov (United States)

    Palade, B; Cioroiu, B; Lazăr, Doina; Corciovă, Andreia; Lazăr, M I

    2010-01-01

    In this paper we followed up the stability of ceftazidime, raw material used in drug industry. Matherials and methods: We used three spectrophotometric methods based on ceftazidime property to form complexes with p-chloranilic acid (ac. p-CA), 3-methylbenzothiazolin-2-on hydrazone (MBTH) and N-(1-naphtil) etilendiamine (NEDA) and a chromatographic method (HPLC). Our results revealed that the substances analyzed maintained minimum content allowable.

  7. Apparatus for observing a sample with a particle beam and an optical microscope

    NARCIS (Netherlands)

    2010-01-01

    An apparatus for observing a sample (1) with a TEM column and an optical high resolution scanning microscope (10). The sample position when observing the sample with the TEM column differs from the sample position when observing the sample with the optical microscope in that in the latter case the

  8. Salicylate-spectrophotometric determination of inorganic monochloramine

    International Nuclear Information System (INIS)

    Tao Hui; Chen Zhonglin; Li Xing; Yang Yanling; Li Guibai

    2008-01-01

    On the basis of classical Berthelot reaction, a simple salicylate-spectrophotometric method was developed for quantitative determination of inorganic monochloramine in water samples. With the catalysis of disodium pentacyanonitrosylferrate(III), inorganic monochloramine reacts with salicylate in equimolar to produce indophenol compound which has an intense absorption at 703 nm. Parameters that influence method performance, such as pH, dosage of salicylate and nitroprussiate and reaction time, were modified to enhance the method performance. By using this method, inorganic monochloramine can be distinguished from organic chloramines and other inorganic chlorine species, such as free chlorine, dichloramine, and trichloramine. The molar absorptivities of the final products formed by these compounds are below ±3% of inorganic monochloramine, because of the α-N in them have only one exchangeable hydrogen atom, and cannot react with salicylate to produce the indophenol compound. The upper concentrations of typical ions that do not interfere with the inorganic monochloramine determination are also tested to be much higher than that mostly encountered in actual water treatment. Case study demonstrates that the results obtained from this method are lower than DPD-titrimetric method because the organic chloramines formed by chlorination of organic nitrogenous compounds give no response in the newly established method. And the result measured by salicylate-spectrophotometric method is coincident with theoretical calculation

  9. Effect of bilirubin on the spectrophotometric and radionuclide assay for serum angiotensin-converting enzyme

    International Nuclear Information System (INIS)

    Saxe, A.W.; Hollinger, M.A.; Essam, T.

    1986-01-01

    The effect of bilirubin on serum angiotensin-converting enzyme (ACE) activity was studied with spectrophotometric and radionuclide assays. In the spectrophotometric assay addition of bilirubin to normal serum from dog, mouse, and human produced a dose-related inhibition of ACE activity. A 50% decrease in human ACE activity was produced by the addition of approximately 250 mg/L in vitro. Serum from icteric patients with elevated bilirubin was also associated with a reduction in ACE activity in the spectrophotometric assay. A 50% decrease in ACE activity in these samples was associated with a serum bilirubin of approximately 220 mg/L. In the radionuclide assay, however, addition of bilirubin to normal human serum failed to reduce measured ACE activity. The use of a radionuclide assay for serum ACE in clinical samples offers the advantage of less interference from serum bilirubin

  10. Optical Observations of X-ray Bright, Optically Normal Galaxies

    Science.gov (United States)

    Sadun, Alberto C.; Aryan, N. S.; Ghosh, K. K.

    2007-05-01

    X-ray bright, optically normal galaxies (XBONGs) are galaxies that seem to have normal spectra and morphology, but are relatively bright x-ray sources. The large ratio of the x-ray to optical emission suggests that some activity, similar to that of active galactic nuclei (AGN), is occurring. Since the galaxies do not show any obvious sign of nuclear activity in their optical spectra, one possible explanation is that these galaxies do not have an optically thick accretion disk at small radii, as previously assumed. Previous data for NGC 7626 classifies it as an XBONG, and so we are studying optical features of this galaxy in order to determine better its features. After confirming an x-ray jet, we are now comparing this to optical features that we have found, including warped dust lanes and a possible optical jet.

  11. New simple spectrophotometric assay of total carotenes in margarines

    NARCIS (Netherlands)

    Luterotti, S.; Bicanic, D.D.; Pozgaj, R.

    2006-01-01

    Direct and reliable spectrophotometric method for assaying total carotenes (TC) in margarines with the minimum of sample manipulation is proposed. For the first time saponification step used in determination of carotenes in margarines was omitted leading to a substantial cost saving and reduction of

  12. Spectrophotometric study on beryllium complex with Chromazurol S in the presence of zephiramine

    International Nuclear Information System (INIS)

    Nishida, Hiroshi

    1982-01-01

    Beryllium(II) reacted with Chromazurol S (CAS, H 4 L) to produce two types of 1:2 complexes in the presence of zephiramine, one of which was in a form of mononuclear Be(HL) 2 4 - showing an absorption maximum at 612 nm and other was in binuclear Be 2 (OH)(HL) 4 9 - showing an absorption maximum at 525 nm. The formation equilibrium of these complexes in the range of pH 5 to 10 was examined by the spectrophotometric method. The binuclear complex was found to be produced from the hydrolysis of the mononuclear complex through the following equation; Be(HL) 2 4 - + 1/2H 2 O reversible 1/2Be 2 (OH)(HL) 4 9 - + 1/2H + where zephiramine ion was not shown. The effect of anions such as chloride and sulfate ions on this equilibrium was observed. The apparent equilibrium constant decreased with the increase of the anion concentrations. The equilibrium constant was larger in the presence of sulfate ion than in chloride ion at the same concentration. In the practical spectrophotometric determination, however, these effects by such diverse ions could be successfully elimination by raising the pH to 10 so high as the above equilibrium was shifted rightward thoroughly. (author)

  13. Spectrophotometric titration of zirconium in siliceous materials

    International Nuclear Information System (INIS)

    Sugawara, K.F.; Su, Y.-S.; Strzegowski, W.R.

    1978-01-01

    An accurate and selective complexometric titration procedure based upon a spectrophotometrically detected end-point has been developed for the determination of zirconium in glasses, glass-ceramics and refractories. A p-bromomandelic acid separation step for zirconium imparts excellent selectivity to the procedure. The method is particularly important for the 1 to 5% concentration range where a simple, accurate and selective method for the determination of zirconium has been lacking. (author)

  14. NEW SPECTROPHOTOMETRIC METHOD WITH KMnO 4 FOR ...

    African Journals Online (AJOL)

    The new method, an instrument-based and simple experimental procedure involves the reaction of the hypochlorite with arsenious oxide (As2O3) (pH 6.5) followed by the coupled reaction of residual As2O3 with permanganate at acidic pH. A titration procedure is described and spectrophotometric method is designed using ...

  15. Ultra-violet Spectrophotometric Determination of Caffeine in Soft and Energy Drinks Available in Yenagoa, Nigeria

    OpenAIRE

    Amos-Tautua; W. Bamidele Martin; E.R.E. Diepreye

    2014-01-01

    This study was carried out to determine the pH and levels of caffeine in eight brands of carbonated and energy drinks available in local market in Yenagoa, Nigeria. Quantitative analysis of caffeine was performed by a simple and fast standard UV spectrophotometric method, using carbon tetrachloride as the extracting solvent. Results showed that the pH of the beverages were slightly acidic ranging from 5.92-6.44. The minimum caffeine level was observed in the carbonated soft drink Coca Cola (4...

  16. Spectrophotometric high-precision seawater pH determination for use in underway measuring systems

    Directory of Open Access Journals (Sweden)

    S. Aßmann

    2011-10-01

    Full Text Available Autonomous sensors are required for a comprehensive documentation of the changes in the marine carbon system and thus to differentiate between its natural variability and anthropogenic impacts. Spectrophotometric determination of pH – a key variable of the seawater carbon system – is particularly suited to achieve precise and drift-free measurements. However, available spectrophotometric instruments are not suitable for integration into automated measurement systems (e.g. FerryBox since they do not meet the major requirements of reliability, stability, robustness and moderate cost. Here we report on the development and testing of a~new indicator-based pH sensor that meets all of these requirements. This sensor can withstand the rough conditions during long-term deployments on ships of opportunity and is applicable to the open ocean as well as to coastal waters with a complex matrix and highly variable conditions. The sensor uses a high resolution CCD spectrometer as detector connected via optical fibers to a custom-made cuvette designed to reduce the impact of air bubbles. The sample temperature can be precisely adjusted (25 °C ± 0.006 °C using computer-controlled power supplies and Peltier elements thus avoiding the widely used water bath. The overall setup achieves a measurement frequency of 1 min−1 with a precision of ±0.0007 pH units, an average offset of +0.0005 pH units to a reference system, and an offset of +0.0081 pH units to a certified standard buffer. Application of this sensor allows monitoring of seawater pH in autonomous underway systems, providing a key variable for characterization and understanding of the marine carbon system.

  17. Spectrophotometric Evaluation of the Pulpal Peroxide Levels in Intact and Restored Teeth - An Invitro Study.

    Science.gov (United States)

    Patri, Gaurav; Acharya, Gourismita; Agrawal, Pratik; Panda, Vijeta

    2016-08-01

    Hydrogen peroxide (30%) is a commonly used "in office" bleaching agent. Deleterious effects of hydrogen peroxide on the pulp have been observed. The present study was conducted with the aim to evaluate the penetration of 30% hydrogen peroxide into the pulp chamber through intact teeth and through the surface of teeth, restored with either hybrid composite or Resin Modified Glass Ionomer Cement (RMGIC). Sixty extracted human maxillary central incisors were selected and divided into six groups. Two groups were restored with hybrid composite resin and two with RMGIC, while two groups were left intact. The teeth with acetate buffer solution in their pulp cavity were then immersed in either 30% hydrogen peroxide or distilled water depending upon the group, for 60 minutes at 37°C. Then horseradish peroxidase and leucocrystal violet were added to the acetate buffer solution present in the pulp chamber after it was transferred to a test tube and the optical density of the resultant blue solution obtained was measured spectrophotometrically. The data obtained were analyzed using one way ANOVA and Student's t-test. The data obtained established that hydrogen peroxide penetrated into the pulp from the bleaching agent used. Hydrogen peroxide (30%) showed the highest pulpal peroxide level in teeth restored with RMGIC followed by teeth restored with hybrid composite resin and the least amount of penetration was observed in intact teeth. The amount of peroxide penetration into the tooth is more through restored tooth than intact tooth and is also dependant on the type of restorative materials used.

  18. Eliminating amino acid interference during spectrophotometric NH4+ analysis

    NARCIS (Netherlands)

    Ros, G.H.; Leeuwen, van A.G.; Temminghoff, E.J.M.

    2011-01-01

    Amino acids can interfere with NH4+ in spectrophotometric NH4+ determination hampering accurate quantification of the fate of NH4+ and dissolved organic N in soils. Serious interference has been reported for soils rich in organic matter, and for soils that have been fumigated, oven-dried or

  19. Optical design constrains in triangular Sagnac imaging interferometers for earth observation

    Science.gov (United States)

    Barducci, A.; Guzzi, D.; Lastri, C.; Nardino, V.; Pippi, I.

    2017-11-01

    The Italian Space Agency selected the imaging interferometer ALISEO (Aerospace Leap-frog Imaging Stationary interferometer for Earth Observation) as the main payload for a technological optical mission based on the small satellite MIOsat. The simple design of such an instrument, based on Sagnac configuration, makes it a promising for Earth observation missions. The ALISEO instrument acquires an image of 10 Km by 10 Km with a spatial resolution better than 10 m and a spectral resolution of 200 cm-1 (7 nm @ 0.6 μm) in the 0.4 - 1 μm spectral range. ALISEO does not employ any moving part to generate the phase delays between the two interfering beams. The sensor acquires target images modulated by a pattern of autocorrelation functions of the energy coming from each scene pixel, and the resulting fringe pattern remains fixed with respect to the instrument's field-of-view. The complete interferogram of each target location is retrieved by introducing a relative source-observer motion, which allows any image pixels to be observed under different viewing-angles corresponding to different Optical Path Differences (OPDs). In this paper various optical configurations are analyzed in order to meet the mission requirements. Optical configurations are discussed taking into account: detector size, spatial resolution, and entrance pupil aperture. The proposed configurations should avoid vignetting, reduce geometric and chromatic aberrations, and comply with the size and weight constrains requested by space mission. Optical configurations, based on both refractive and reflective focusing elements, are presented and discussed. Finally, some properties pertaining to the selected Sagnac configuration are discussed in conjunction with spectral estimations and data processing.

  20. EARLY OPTICAL OBSERVATIONS OF GAMMA-RAY BURSTS BY THE TAROT TELESCOPES: PERIOD 2001-2008

    International Nuclear Information System (INIS)

    Klotz, A.; Boer, M.; Atteia, J. L.; Gendre, B.

    2009-01-01

    The Telescopes a Action Rapide pour les Objets Transitoires telescopes are two robotic observatories designed to observe the prompt optical emission counterpart and the early afterglow of gamma-ray bursts (GRBs). We present data acquired between 2001 and 2008 and discuss the properties of the optical emission of GRBs, noting various interesting results. The optical emission observed during the prompt GRB phase is rarely very bright: we estimate that 5%-20% of GRBs exhibit a bright optical flash (R < 14) during the prompt gamma-ray emission, and that more than 50% of the GRBs have an optical emission fainter than R = 15.5 when the gamma-ray emission is active. We study the apparent optical brightness distribution of GRBs at 1000 s showing that our observations confirm the distribution derived by other groups. The combination of these results with those obtained by other rapid slewing telescopes allows us to better characterize the early optical emission of GRBs and to emphasize the importance of very early multiwavelength GRB studies for the understanding of the physics of the ejecta.

  1. OPTICAL SETI OBSERVATIONS OF THE ANOMALOUS STAR KIC 8462852

    International Nuclear Information System (INIS)

    Schuetz, Marlin; Vakoch, Douglas A.; Shostak, Seth; Richards, Jon

    2016-01-01

    To explore the hypothesis that KIC 8462852's aperiodic dimming is caused by artificial megastructures in orbit, rather than a natural cause such as cometary fragments in a highly elliptical orbit, we searched for electromagnetic signals from KIC 8462852 indicative of extraterrestrial intelligence. The primary observations were in the visible optical regime using the Boquete Optical SETI Observatory in Panama. In addition, as a recommended preparatory exercise for the possible future detection of a candidate signal, three of six observing runs simultaneously searched radio frequencies at the Allen Telescope Array in California. No periodic optical signals greater than 67 photons m −2 within a time frame of 25 ns were seen. If, for example, any inhabitants of KIC 8462852 were targeting our solar system with 5 MJ laser pulses, locally illuminating an approximately 3 au diameter disk, the signal could have been detected at the Boquete Observatory. The limits on narrowband radio signals were 180–300 Jy Hz at 1 and 8 GHz, respectively. While the power requirement for a detectable, isotropic narrowband radio transmission from KIC 8462852 is quite high, even modest targeting on the part of the putative extraterrestrials can lower this power substantially.

  2. Optical SETI Observations of the Anomalous Star KIC 8462852

    Science.gov (United States)

    Schuetz, Marlin; Vakoch, Douglas A.; Shostak, Seth; Richards, Jon

    2016-07-01

    To explore the hypothesis that KIC 8462852's aperiodic dimming is caused by artificial megastructures in orbit, rather than a natural cause such as cometary fragments in a highly elliptical orbit, we searched for electromagnetic signals from KIC 8462852 indicative of extraterrestrial intelligence. The primary observations were in the visible optical regime using the Boquete Optical SETI Observatory in Panama. In addition, as a recommended preparatory exercise for the possible future detection of a candidate signal, three of six observing runs simultaneously searched radio frequencies at the Allen Telescope Array in California. No periodic optical signals greater than 67 photons m-2 within a time frame of 25 ns were seen. If, for example, any inhabitants of KIC 8462852 were targeting our solar system with 5 MJ laser pulses, locally illuminating an approximately 3 au diameter disk, the signal could have been detected at the Boquete Observatory. The limits on narrowband radio signals were 180-300 Jy Hz at 1 and 8 GHz, respectively. While the power requirement for a detectable, isotropic narrowband radio transmission from KIC 8462852 is quite high, even modest targeting on the part of the putative extraterrestrials can lower this power substantially.

  3. Observations of regional and local variability in the optical properties of maritime clouds

    Energy Technology Data Exchange (ETDEWEB)

    White, A.B. [Univ. of Colorado at Boulder/National Oceanic and Atmospheric Administration, Boulder, CO (United States); Fairall, C.W. [Environmental Technology Lab., Boulder, CO (United States)

    1996-04-01

    White and Fairall (1995) calculated the optical properties of the marine boundary layer (MBL) clouds observed during the Atlantic Stratocumulus Transition Experiment (ASTEX) and compared their results with the results obtained by Fairall et al. for the MBL clouds observed during the First International Satellite Climatology Program (ISSCP) Regional Experiment (FIRE). They found a factor of two difference in the optical depth versus liquid water relationship that applies to the clouds observed in each case. In the present study, we present evidence to support this difference. We also investigate the local variability exhibited in the ASTEX optical properties using measurements of the boundary layer aerosol concentration.

  4. A Spectrophotometric Method for the Determination of Ramipril in ...

    African Journals Online (AJOL)

    A Spectrophotometric Method for the Determination of Ramipril in Solid Dosage Forms. ... Tropical Journal of Pharmaceutical Research ... Methods: UV spectrophotometry was used to develop and validate a simple method for the assay of ramipril in solid dosage form at λmax of 210 nm, as per International Conference on ...

  5. Spectrophotometric determination of aluminium in steel with xylenol orange

    International Nuclear Information System (INIS)

    Majeed, A.; Javed, N.; Khan, M.S.

    1996-01-01

    Spectrophotometric determination of Aluminium in steel based on colour reaction between Aluminium and xylenol orange has been carried out. Red coloured complex formed in weak acidic solution is measured for its absorbance at 550 nm. The various optimum experimental conditions for Aluminium xylenol orange (Al-Xo) complex have been studied. (author)

  6. Extractive Spectrophotometric Methods for the Determination of Etoricoxib in Tablets

    Directory of Open Access Journals (Sweden)

    Kamal Shah

    2009-01-01

    Full Text Available Two simple, rapid, sensitive, precise and economic spectrophotometric methods have been developed for the estimation of etoricoxib in tablet formulation. During the course of study, it was observed that acidic solution of the drug formed colored ion-association complexes with Bromocresol Green (BCG and Bromocresol Purple (BCP which were soluble in chloroform. This property of the drug was followed for the development of colorimetric methods for analysis of drug. The complex of etoricoxib with BCG and BCP showed λmax at 416 nm and 408 nm respectively. These methods were validated statistically. Recovery studies gave satisfactory results indicating that none of common additives and excipients interfere the assay method. The proposed methods are found to be simple, accurate and reproducible that was successfully applied for the analysis of tablet formulation.

  7. Analysis of nearly simultaneous x-ray and optical observations of active galactic nuclei

    International Nuclear Information System (INIS)

    Webb, J.R.

    1988-01-01

    Rosemary Hill optical and EINSTEIN X-ray observations of a sample of 36 galactic nuclei (AGN) were reduced and analyzed. Seventy-two x-ray observations of these sources were reduced, nineteen of which yielded spectral information. Of these spectra observations, significant hydrogen column densities above the galactic value were required for nine of the active galactic nuclei. X-ray variability was detected in eight of the eleven sources which were observed more than once by EINSTEIN. Correlations between the x-ray and optical luminosities were investigated using the Jefferys method of least squares. This method allows for errors in both variables. The results indicate a strong correlation between the x-ray and optical luminosities for the entire sample. Division of the sample into groups with similar optical variability characteristics show that the less violently violent variable AGN are more highly correlated than the violently variable blazars. Infrared and radio observations were combined with the x-ray and optical observations of six AGN. These sources were modelled in terms of the synchrotron-self-Compton model. The turnover frequency falls between the infrared and radio data and reliable estimates of this parameter are difficult to estimate. Therefore the results were found as a function of the turnover frequency. Four sources required relativistic bulk motion or beaming. Multifrequency spectra made at different times for one individual source, 0235+164, required different amounts of beaming to satisfy the x-ray observations. Sizes of the emitting regions for the sources modelled ranged from 0.5 parsec to 1.0 parsec

  8. Study of the optical and x-ray properties of quasars

    International Nuclear Information System (INIS)

    Bradley, S.E.

    1985-01-01

    It is now widely believed that photoionization by the central nucleus is primarily responsible for the emission lines observed in quasars. If this view is correct, x-ray wavelength photons from the nucleus could play a role in determining the emission line strengths of the various chemical species present in quasars. Indeed, recent photoionization models predict the enhancement of some emission lines arising from an extended ionized zone heated by soft x-rays. In an attempt to investigate this possibility, a sample of 17 quasars exhibiting a wide range of x-ray to optical luminosities has been observed spectrophotometrically in an effort to correlate their optical spectroscopic features with published x-ray and radio luminosities. Such correlations are known to exist for Seyfert galaxies, but at present it is unclear whether quasars also exhibit these correlations. All of the quasars in this sample have been previously observed with the Einstein Observatory. Strengths of the broad permitted emission lines as well as the narrow forbidden lines are analyzed for correlations with the x-ray strength and the optical strength; also, ratios of lines such as Hβ to [O III] and Fe II to Hβ are considered, as well as high excitation lines such as [Ne V]. Because of the difficulty in obtaining high signal-to-noise data for objects as faint as quasars, resolving this issue may well require many such studies as this one, each contributing a fraction of knowledge to the whole, before the question can adequately be answered

  9. Observation of a new magneto-optical trap

    International Nuclear Information System (INIS)

    Emile, O.; Bardou, F.; Salomon, C.; Laurent, P.; Nadir, A.; Clairon, A.

    1992-01-01

    We report on the observation of a new laser trap for neutral atoms. It uses three orthogonal pairs of counterpropagating laser beams having linear polarizations at 45deg and a quadrupole magnetic field. 10 8 cesium atoms were thus confined in a 0.15 mm 3 volume at a temperature of 60 μK, a factor of 2 below the Doppler cooling limit. We interpret this trapping as being due to the new magneto-optical force recently observed by Grimm et al. and which is essentially a dipole force rectified by the magnetic field. This trap opens new possibilities for increasing the phase-space density of laser-cooled atoms. (orig.)

  10. Validation of a spectrophotometric method for quantification of carboxyhemoglobin.

    Science.gov (United States)

    Luchini, Paulo D; Leyton, Jaime F; Strombech, Maria de Lourdes C; Ponce, Julio C; Jesus, Maria das Graças S; Leyton, Vilma

    2009-10-01

    The measurement of carboxyhemoglobin (COHb) levels in blood is a valuable procedure to confirm exposure to carbon monoxide (CO) either for forensic or occupational matters. A previously described method using spectrophotometric readings at 420 and 432 nm after reduction of oxyhemoglobin (O(2)Hb) and methemoglobin with sodium hydrosulfite solution leads to an exponential curve. This curve, used with pre-established factors, serves well for lower concentrations (1-7%) or for high concentrations (> 20%) but very rarely for both. The authors have observed that small variations on the previously described factors F1, F2, and F3, obtained from readings for 100% COHb and 100% O(2)Hb, turn into significant changes in COHb% results and propose that these factors should be determined every time COHb is measured by reading CO and O(2) saturated samples. This practice leads to an increase in accuracy and precision.

  11. Spectrophotometric Determination of Phenolic Antioxidants in the Presence of Thiols and Proteins

    Directory of Open Access Journals (Sweden)

    Aslı Neslihan Avan

    2016-08-01

    Full Text Available Development of easy, practical, and low-cost spectrophotometric methods is required for the selective determination of phenolic antioxidants in the presence of other similar substances. As electron transfer (ET-based total antioxidant capacity (TAC assays generally measure the reducing ability of antioxidant compounds, thiols and phenols cannot be differentiated since they are both responsive to the probe reagent. In this study, three of the most common TAC determination methods, namely cupric ion reducing antioxidant capacity (CUPRAC, 2,2′-azinobis(3-ethylbenzothiazoline-6-sulfonic acid diammonium salt/trolox equivalent antioxidant capacity (ABTS/TEAC, and ferric reducing antioxidant power (FRAP, were tested for the assay of phenolics in the presence of selected thiol and protein compounds. Although the FRAP method is almost non-responsive to thiol compounds individually, surprising overoxidations with large positive deviations from additivity were observed when using this method for (phenols + thiols mixtures. Among the tested TAC methods, CUPRAC gave the most additive results for all studied (phenol + thiol and (phenol + protein mixtures with minimal relative error. As ABTS/TEAC and FRAP methods gave small and large deviations, respectively, from additivity of absorbances arising from these components in mixtures, mercury(II compounds were added to stabilize the thiol components in the form of Hg(II-thiol complexes so as to enable selective spectrophotometric determination of phenolic components. This error compensation was most efficient for the FRAP method in testing (thiols + phenols mixtures.

  12. Kinetic Spectrophotometric Determination of Certain Cephalosporins in Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Mahmoud A. Omar

    2009-01-01

    Full Text Available A simple, reliable, and sensitive kinetic spectrophotometric method was developed for determination of eight cephalosporin antibiotics, namely, Cefotaxime sodium, Cephapirin sodium, Cephradine dihydrate, Cephalexin monohydrate, Ceftazidime pentahydrate, Cefazoline sodium, Ceftriaxone sodium, and Cefuroxime sodium. The method depends on oxidation of each of studied drugs with alkaline potassium permanganate. The reaction is followed spectrophotometrically by measuring the rate of change of absorbance at 610 nm. The initial rate and fixed time (at 3 minutes methods are utilized for construction of calibration graphs to determine the concentration of the studied drugs. The calibration graphs are linear in the concentration ranges 5–15 g mL−1 and 5–25 g mL−1 using the initial rate and fixed time methods, respectively. The results are validated statistically and checked through recovery studies. The method has been successfully applied for the determination of the studied cephalosporins in commercial dosage forms. Statistical comparisons of the results with the reference methods show the excellent agreement and indicate no significant difference in accuracy and precision.

  13. Liquid chromatographic and spectrophotometric methods for the determination of erythromycin stearate and trimethoprim in tablets

    Directory of Open Access Journals (Sweden)

    Sonia T. Hassib

    2011-12-01

    Full Text Available Simple, accurate and precise reversed-phase liquid chromatographic (LC and spectrophotometric methods have been developed and validated for the determination of erythromycin stearate (ERS and trimethoprim (TMP in mixture. In LC method, chromatographic separation was achieved on a Symmetry® Waters C18 column (150 × 4.6 mm, 5 μm based on isocratic elution using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (9:acetonitrile:water (25:100:50, v/v/v at a flow rate of 1.6 ml min−1 with UV detection at 210 nm for ERS and 280 nm for TMP. Besides, two spectrophotometric methods were applied after reaction with perchloric acid (12 M which gives a colored product with ERS. Then, the spectral interference between the colored product of ERS and TMP was resolved by either ratio spectra derivative spectrophotometry in the first spectrophotometric method or chemometric techniques, namely classical least-squares (CLS, principal component regression (PCR and partial least-squares regression (PLS in the second spectrophotometric method. The results were statistically compared using one-way analysis of variance (ANOVA. The methods developed were satisfactorily applied to the analysis of the pharmaceutical preparation containing the two drugs and proved to be specific and accurate for the quality control of the cited drugs in pharmaceutical dosage forms.

  14. OPTICAL SETI OBSERVATIONS OF THE ANOMALOUS STAR KIC 8462852

    Energy Technology Data Exchange (ETDEWEB)

    Schuetz, Marlin; Vakoch, Douglas A. [METI International, 100 Pine Street, Suite 1250, San Francisco, CA 94111-5235 (United States); Shostak, Seth; Richards, Jon, E-mail: dvakoch@meti.org [Center for SETI Research, SETI Institute, 189 Bernardo Avenue, Mountain View, CA 94043 (United States)

    2016-07-01

    To explore the hypothesis that KIC 8462852's aperiodic dimming is caused by artificial megastructures in orbit, rather than a natural cause such as cometary fragments in a highly elliptical orbit, we searched for electromagnetic signals from KIC 8462852 indicative of extraterrestrial intelligence. The primary observations were in the visible optical regime using the Boquete Optical SETI Observatory in Panama. In addition, as a recommended preparatory exercise for the possible future detection of a candidate signal, three of six observing runs simultaneously searched radio frequencies at the Allen Telescope Array in California. No periodic optical signals greater than 67 photons m{sup −2} within a time frame of 25 ns were seen. If, for example, any inhabitants of KIC 8462852 were targeting our solar system with 5 MJ laser pulses, locally illuminating an approximately 3 au diameter disk, the signal could have been detected at the Boquete Observatory. The limits on narrowband radio signals were 180–300 Jy Hz at 1 and 8 GHz, respectively. While the power requirement for a detectable, isotropic narrowband radio transmission from KIC 8462852 is quite high, even modest targeting on the part of the putative extraterrestrials can lower this power substantially.

  15. Spectrophotometric method for the determination of thorium in UO2 pellets

    International Nuclear Information System (INIS)

    Acosta L, E.

    1995-04-01

    This report presents a procedure with the description of the spectrophotometric method for the determination of the thorium element in uranium products including powders and pellets of uranium dioxide. Quantities can be determined starting from 1 ppm. (Author)

  16. Early GRB optical and infrared afterglow observations with the 2-m robotic Liverpool Telescope

    International Nuclear Information System (INIS)

    Gomboc, A.; Ljubljana Univ., Ljubljana; Mundell, C.G.; Guidorzi, C.

    2005-01-01

    We present the first optical observations of a Gamma Ray Burst IGRB) afterglow using the 2-m robotic Liverpool Telescope (LT), which is owned and operated by Liverpool John Moores University and situated on La Palma. We briefly discuss the capabilities of LT and its suitability for rapid follow-up observations of early optical and infrared GRB light curves. In particular, the combination of aperture, site, instrumentation and rapid response (robotic over-ride mode aided by telescope's rapid slew and fully-opening enclosure) makes the LT ideal for investigating the nature of short bursts, optically-dark bursts, and GRB blast-wave physics in general. We briefly describe the LT's key position in the RoboNet-1.0 network of robotic telescopes. We present the LT observations of GRB041006 and use its gamma-ray properties to predict the time of the break in optical light curve, a prediction consistent with the observations

  17. Spectrophotometric determination of metals in Pakistani and foreign brand cigarette tobacco

    International Nuclear Information System (INIS)

    Ikram, M.; Rauf, M.A.; Ali, S.; Iqbal, M.

    2001-01-01

    Tobacco smoking and related uses are major cause of various diseases in human beings. In the present study forty one various brands of cigarettes from Pakistan, United States, United Kingdom and Japan have been selected for determination of iron, nickel and copper spectrophotometrically. The concentration of Fe, Ni and Cu in tobacco of each forty-one brands of national and foreign brands cigarette is given in this article. The spectrophotometric determination of Fe, Ni and Cu in forty one brands of national and foreign cigarettes reveals that the concentrations of these metals depends on different conditions, such as soil condition, fertilizer and sprays during the tobacco growth. However, Cigarette manufacturing companies could have a significant role in their concentration levels. The results obtained by this technique are in good agreement with the reported literature values. (A.B.)

  18. Liquid-liquid microextraction in a multicommuted flow system for direct spectrophotometric determination of iodine value in biodiesel.

    Science.gov (United States)

    Pereira, Andréia C; Rocha, Fábio R P

    2014-06-04

    A flow-based procedure was developed for the direct spectrophotometric determination of the iodine value (IV) in biodiesel. The procedure was based on the microextraction/reaction of unsaturated compounds with triiodide ions in an aqueous medium by inserting the reagent solution between the aliquots of biodiesel without any pretreatment. The interaction occurred through the biodiesel film formed on the inner walls of the hydrophobic tube used as the reactor and at the aqueous/biodiesel interfaces. The spectrophotometric detection was based on the discoloration of the I3(-) reagent in the aqueous phase by using a glass tube coupled to a fiber-optic spectrophotometer as the detection cell. Reference solutions were prepared by dilution of biodiesel samples with previously determined IV in hexane. The analytical response was linear for IV from 13 to 135 g I2/100 g with a detection limit of 5 g I2/100 g. A coefficient of variation of 1.7% (n=10) and a sampling rate of 108 determinations per hour were achieved by consuming 224 μL of the sample and 200 μg of I2 per determination. The slopes of analytical curves obtained with three different biodiesel samples were in agreement (variations in slopes lower than 3.1%), thus indicating an absence of any matrix effects. Results for biodiesel samples from different sources agreed with the volumetric official procedure at the 95% confidence level. The proposed procedure is therefore a simple, fast, and reliable alternative for estimating the iodine value of biodiesel. Copyright © 2014. Published by Elsevier B.V.

  19. A Fiber Optic System For The Detection Of Entero-Gastric Reflux

    Science.gov (United States)

    Falciai, R.; Baldini, F.; Conforti, G.; Cosi, F.; Scheggi, A. M...; Bechi, P.

    1989-01-01

    The study and the development of an optical fiber sensor for entero-gastric and non-acid gastro-esophageal reflux is described. The working principle, based on the spectrophotometric properties of the bile, which constitutes the main part of the reflux, differs from the traditional measurement method, based on pH monitoring. The measuring apparatus is described as well as experimental "in vitro" and preliminary "in vivo" tests are reported.

  20. Stellar observations with the Voyager EUV objective grating spectrograph

    International Nuclear Information System (INIS)

    Holberg, J.B.; Polidan, R.S.; Barry, D.C.

    1986-01-01

    During the periods of interplanetary cruise the Voyager ultraviolet spectrometers are used to provide unique and otherwise unobtainable observations in the extreme ultraviolet (EUV, 500 to 1200) and the far ultraviolet (FUV, 912 to 1220 A). These observations include the spectra of hot stellar sources as well as emission from the interplanetary medium. Recent results of note include: (1) extensive spectrophotometric coverage of a superoutburst of the dwarf nova VW Hydri, which showed a clear 1/2 day delay in the outburst at 1000 A relative to that observed in the optical and a curious dip in the FUV light curve near maximum light. The Voyager observations were part of a comprehensive and highly successful campaign involving EXOSAT, IUE and ground based observations of this dwarf nova; (2) a comprehensive study of Be star spectra and variability. These results show the critical importance of FUV observations in the study of the effects of stellar rotation in hot stars; (3) the detection of a strong O VI absorption feature in the spectrum of the PG 1159-like object H1504+65. This detection along with the optical identification of weak O IV lines was a key to the interpretation of this object; which is of extremely high (>150,000K) temperature and appears to be a unique example of a stellar atmosphere devoid of H and He; (4) an analysis of an extremely long duration spectrum of the EUV and FUV sky background, which establishes important new upper limits on both continuum and line emission. This result also provide the first detection of interplanetary Lyman gamma

  1. Validated UV-Spectrophotometric Methods for Determination of Gemifloxacin Mesylate in Pharmaceutical Tablet Dosage Forms

    Directory of Open Access Journals (Sweden)

    R. Rote Ambadas

    2010-01-01

    Full Text Available Two simple, economic and accurate UV spectrophotometric methods have been developed for determination of gemifloxacin mesylate in pharmaceutical tablet formulation. The first UV-spectrophotometric method depends upon the measurement of absorption at the wavelength 263.8 nm. In second area under curve method the wavelength range for detection was selected from 268.5-258.5 nm. Beer’s law was obeyed in the range of 2 to 12 μgmL-1 for both the methods. The proposed methods was validated statistically and applied successfully to determination of gemifloxacin mesylate in pharmaceutical formulation.

  2. Spectrophotometric studies of transcurium element halides and oxyhalides in the solid state

    International Nuclear Information System (INIS)

    Young, J.P.; Haire, R.G.; Fellows, R. L.; Peterson, J.R.

    1978-01-01

    The present state of a microscale spectrophotometric technique is described. The application of spectrophotometry to transcurium elements (Bk, Cf, Es) requires some rather specialized microtechniques for the following reasons: only small amounts of these elements are available; their radioactivity makes the use of μg-sized samples desirable; and spectral study of solids requires thin samples. A schematic diagram of the microscope-spectrophotometer used for spectrophotometric study of the transcurium element compounds is shown. The spectrophotometer, of local design, consists of two microscopes equipped with Cassegrainian reflecting microscope objective lenses, a quartz field lens, and a Jarrell Ash 1/2 meter scanning monochromator equipped with a 1180 line/mm grating blazed at 4000 A. The photomultiplier used in this system is an S-1 type RCA 7102 operated at approximately -50 deg C. This grating-photomultiplier combination provides a continuous response free of discontinuities over the useful wavelength range of the system from 3000 to 11 000 A. The microscope-spectrophotometer is a single beam instrument. Each spectral trace is registered as photomultiplier current on a strip chart recorder. In order to obtain true absorption spectra, however, the output from the photometer is also simultaneously digitized for on-line processing. The unique advantages of applying both spectrophotometric and X-ray powder diffraction methods on the sample, in order to identify and characterize newly synthesized compounds, are also discussed. (T.G.)

  3. Dibenzazepin hydrochloride as a new spectrophotometric reagent for determination of hydrogen peroxide in plant extracts.

    Science.gov (United States)

    Nagaraja, P; Prakash, J S; Asha, S C; Bhaskara, B L; Kumar, S Anil

    2012-10-01

    A rapid, simple, accurate, and sensitive visible spectrophotometric method for the determination of trace amounts of hydrogen peroxide in acidic buffer medium is reported. The proposed method is based on the oxidative coupling of Ampyrone with dibenzazepin hydrochloride by hydrogen peroxide in the buffer medium of pH 4.0 which is catalyzed by ferrous iron. The blue-colored product formed with maximum absorption at 620 nm was found to be stable for 2 h. Beer's law is obeyed for hydrogen peroxide concentration in the range of 0.03-0.42 μg ml(-1). The optimum reaction conditions and other important optical parameters are reported. The molar absorptive and Sandell's sensitivity are found to be 5.89 × 10(4) mol(-1) cm(-1) and 0.57 g/cm(2), respectively. The interference due to diverse ions and complexing agents was studied. The method is successfully applied to the determination of hydrogen peroxide in green plants satisfactorily.

  4. Study on the Spectrophotometric Detection of Free Fatty Acids in Palm Oil Utilizing Enzymatic Reactions

    Directory of Open Access Journals (Sweden)

    Nur Hidayah Azeman

    2015-07-01

    Full Text Available In this paper, a comprehensive study has been made on the detection of free fatty acids (FFAs in palm oil via an optical technique based on enzymatic aminolysis reactions. FFAs in crude palm oil (CPO were converted into fatty hydroxamic acids (FHAs in a biphasic lipid/aqueous medium in the presence of immobilized lipase. The colored compound formed after complexation between FHA and vanadium (V ion solution was proportional to the FFA content in the CPO samples and was analyzed using a spectrophotometric method. In order to develop a rapid detection system, the parameters involved in the aminolysis process were studied. The utilization of immobilized lipase as catalyst during the aminolysis process offers simplicity in the product isolation and the possibility of conducting the process under extreme reaction conditions. A good agreement was found between the developed method using immobilized Thermomyces lanuginose lipase as catalyst for the aminolysis process and the Malaysian Palm Oil Board (MPOB standard titration method (R2 = 0.9453.

  5. A modified spectrophotometric assay to estimate deglycosylation of steroidal saponin to sapogenin by mixed ruminal microbes.

    Science.gov (United States)

    Wang, Yuxi; McAllister, Tim A

    2010-08-30

    The lack of a method for measuring deglycosylation of saponins in ruminal fluid has limited the ability to investigate the impact of these compounds on rumen microorganisms. A simple spectrophotometric assay was adapted and a protocol developed to enable measurement of steroidal saponin and sapogenin in ruminal fluid. The procedure was used for in vitro determination of deglycosylation activity of rumen bacteria obtained from cattle fed or not fed Yucca schidigera saponin, and to determine the relative deglycosylase activities of extracellular and cell-associated enzymes from ruminal content. Modifications to the spectrophotometric assay (i.e. heating time shortened to 10 min and 0.5 mL dH(2)O added to the reaction mixture) improved the stability of the optical density (425 nm) of the chromophore for up to 24 h post-reaction. Centrifugation (12 000 x g, 20 min) enabled differential estimations of steroidal saponin and sapogenin in ruminal fluid. Steroidal saponin added to defaunated ruminal fluid (dRF) or clarified ruminal fluid (cRF) was recovered completely from the mixture as saponin + sapogenin (99.1% and 100.6%, respectively), whereas saponin recovery from the supernatant of dRF was greatly reduced (P ruminal extracellular enzyme preparation was recoverable in supernatant after 24 h, compared with only 26-32% remaining in supernatant from incubation with a cell-associated enzymes fraction. Mixed rumen bacteria deglycosylate steroidal saponin to sapogenin, at activity levels unaffected by prior exposure to saponin, but they were unable to degrade the sapogenin core structure. Deglycosylation activity occurred primarily in the cell-associated enzyme fraction of ruminal content. Copyright (c) 2008 Crown in the right of Canada. Published by John Wiley & Sons, Ltd.

  6. Parametric spectro-temporal analyzer (PASTA) for real-time optical spectrum observation

    Science.gov (United States)

    Zhang, Chi; Xu, Jianbing; Chui, P. C.; Wong, Kenneth K. Y.

    2013-06-01

    Real-time optical spectrum analysis is an essential tool in observing ultrafast phenomena, such as the dynamic monitoring of spectrum evolution. However, conventional method such as optical spectrum analyzers disperse the spectrum in space and allocate it in time sequence by mechanical rotation of a grating, so are incapable of operating at high speed. A more recent method all-optically stretches the spectrum in time domain, but is limited by the allowable input condition. In view of these constraints, here we present a real-time spectrum analyzer called parametric spectro-temporal analyzer (PASTA), which is based on the time-lens focusing mechanism. It achieves a frame rate as high as 100 MHz and accommodates various input conditions. As a proof of concept and also for the first time, we verify its applications in observing the dynamic spectrum of a Fourier domain mode-locked laser, and the spectrum evolution of a laser cavity during its stabilizing process.

  7. A novel method for spectrophotometric determination of pregabalin in pure form and in capsules

    Directory of Open Access Journals (Sweden)

    Gaur Prateek

    2011-10-01

    Full Text Available Abstract Background Pregabalin, a γ-amino-n-butyric acid derivative, is an antiepileptic drug not yet official in any pharmacopeia and development of analytical procedures for this drug in bulk/formulation forms is a necessity. We herein, report a new, simple, extraction free, cost effective, sensitive and reproducible spectrophotometric method for the determination of the pregabalin. Results Pregabalin, as a primary amine was reacted with ninhydrin in phosphate buffer pH 7.4 to form blue violet colored chromogen which could be measured spectrophotometrically at λmax 402.6 nm. The method was validated with respect to linearity, accuracy, precision and robustness. The method showed linearity in a wide concentration range of 50-1000 μg mL-1 with good correlation coefficient (0.992. The limits of assays detection was found to be 6.0 μg mL-1 and quantitation limit was 20.0 μg mL-1. The suggested method was applied to the determination of the drug in capsules. No interference could be observed from the additives in the capsules. The percentage recovery was found to be 100.43 ± 1.24. Conclusion The developed method was successfully validated and applied to the determination of pregabalin in bulk and pharmaceutical formulations without any interference from common excipients. Hence, this method can be potentially useful for routine laboratory analysis of pregabalin.

  8. Compatible validated spectrofluorimetric and spectrophotometric methods for determination of vildagliptin and saxagliptin by factorial design experiments

    Science.gov (United States)

    Abdel-Aziz, Omar; Ayad, Miriam F.; Tadros, Mariam M.

    2015-04-01

    Simple, selective and reproducible spectrofluorimetric and spectrophotometric methods have been developed for the determination of vildagliptin and saxagliptin in bulk and their pharmaceutical dosage forms. The first proposed spectrofluorimetric method is based on the dansylation reaction of the amino group of vildagliptin with dansyl chloride to form a highly fluorescent product. The formed product was measured spectrofluorimetrically at 455 nm after excitation at 345 nm. Beer's law was obeyed in a concentration range of 100-600 μg ml-1. The second proposed spectrophotometric method is based on the charge transfer complex of saxagliptin with tetrachloro-1,4-benzoquinone (p-chloranil). The formed charge transfer complex was measured spectrophotometrically at 530 nm. Beer's law was obeyed in a concentration range of 100-850 μg ml-1. The third proposed spectrophotometric method is based on the condensation reaction of the primary amino group of saxagliptin with formaldehyde and acetyl acetone to form a yellow colored product known as Hantzsch reaction, measured at 342.5 nm. Beer's law was obeyed in a concentration range of 50-300 μg ml-1. All the variables were studied to optimize the reactions' conditions using factorial design. The developed methods were validated and proved to be specific and accurate for quality control of vildagliptin and saxagliptin in their pharmaceutical dosage forms.

  9. The effect of non-aqueous solvents on spectrophotometric analysis of lead (II)

    International Nuclear Information System (INIS)

    Ramadan, A.A.; Bahbouh, M.; Kamuah, M.

    1992-01-01

    The effect of the following non-aqueous solvents: Methanol, Ethanol, Propanol, iso-propanol, dimethylsulfoxide, dimethylformamide and acetonitrile on spectrophotometric analysis of lead (II) was studied. One absorption peak at range 220-340 nm was observed. The values of maximum wave length (λ max ) and maximum molar absorptivity coefficient (ε max ) vary in accordance with the above solvents and the concentration of HC1. the analytical curves, A=f(C Pb 2+ ), for the determination of lead (II) in presence 5 M HC1 (in methanol) and 7 M HC1 (in other solvents) showed linear proportionality over the concentration range 2.5x10 -5 - 2.0x10 -4 M Pb 2+ . (author). 16 Refs., 4 figs., 2 Tabs

  10. Optical Tracking Data Validation and Orbit Estimation for Sparse Observations of Satellites by the OWL-Net.

    Science.gov (United States)

    Choi, Jin; Jo, Jung Hyun; Yim, Hong-Suh; Choi, Eun-Jung; Cho, Sungki; Park, Jang-Hyun

    2018-06-07

    An Optical Wide-field patroL-Network (OWL-Net) has been developed for maintaining Korean low Earth orbit (LEO) satellites' orbital ephemeris. The OWL-Net consists of five optical tracking stations. Brightness signals of reflected sunlight of the targets were detected by a charged coupled device (CCD). A chopper system was adopted for fast astrometric data sampling, maximum 50 Hz, within a short observation time. The astrometric accuracy of the optical observation data was validated with precise orbital ephemeris such as Consolidated Prediction File (CPF) data and precise orbit determination result with onboard Global Positioning System (GPS) data from the target satellite. In the optical observation simulation of the OWL-Net for 2017, an average observation span for a single arc of 11 LEO observation targets was about 5 min, while an average optical observation separation time was 5 h. We estimated the position and velocity with an atmospheric drag coefficient of LEO observation targets using a sequential-batch orbit estimation technique after multi-arc batch orbit estimation. Post-fit residuals for the multi-arc batch orbit estimation and sequential-batch orbit estimation were analyzed for the optical measurements and reference orbit (CPF and GPS data). The post-fit residuals with reference show few tens-of-meters errors for in-track direction for multi-arc batch and sequential-batch orbit estimation results.

  11. Optical Tracking Data Validation and Orbit Estimation for Sparse Observations of Satellites by the OWL-Net

    Directory of Open Access Journals (Sweden)

    Jin Choi

    2018-06-01

    Full Text Available An Optical Wide-field patroL-Network (OWL-Net has been developed for maintaining Korean low Earth orbit (LEO satellites’ orbital ephemeris. The OWL-Net consists of five optical tracking stations. Brightness signals of reflected sunlight of the targets were detected by a charged coupled device (CCD. A chopper system was adopted for fast astrometric data sampling, maximum 50 Hz, within a short observation time. The astrometric accuracy of the optical observation data was validated with precise orbital ephemeris such as Consolidated Prediction File (CPF data and precise orbit determination result with onboard Global Positioning System (GPS data from the target satellite. In the optical observation simulation of the OWL-Net for 2017, an average observation span for a single arc of 11 LEO observation targets was about 5 min, while an average optical observation separation time was 5 h. We estimated the position and velocity with an atmospheric drag coefficient of LEO observation targets using a sequential-batch orbit estimation technique after multi-arc batch orbit estimation. Post-fit residuals for the multi-arc batch orbit estimation and sequential-batch orbit estimation were analyzed for the optical measurements and reference orbit (CPF and GPS data. The post-fit residuals with reference show few tens-of-meters errors for in-track direction for multi-arc batch and sequential-batch orbit estimation results.

  12. Determination of Modafinil in Tablet Formulation Using Three New Validated Spectrophotometric Methods

    International Nuclear Information System (INIS)

    Basniwal, P.K.; Jain, D.; Basniwal, P.K.

    2014-01-01

    In this study, three new UV spectrophotometric methods viz. linear regression equation (LRE), standard absorptivity (SA) and first order derivative (FOD) method were developed and validated for determination of modafinil in tablet form. The Beer-Lamberts law was obeyed as linear in the range of 10-50 μg/ mL and all the methods were validated for linearity, accuracy, precision and robustness. These methods were successfully applied for assay of modafinil drug content in tablets in the range of 100.20 - 100.42 %, 100.11 - 100.58 % and 100.25 - 100.34 %, respectively with acceptable standard deviation (less than two) for all the methods. The validated spectrophotometric methods may be successfully applied for assay, dissolution studies, bio-equivalence studies as well as routine analysis in pharmaceutical industries. (author)

  13. Optics. Observation of optical polarization Möbius strips.

    Science.gov (United States)

    Bauer, Thomas; Banzer, Peter; Karimi, Ebrahim; Orlov, Sergej; Rubano, Andrea; Marrucci, Lorenzo; Santamato, Enrico; Boyd, Robert W; Leuchs, Gerd

    2015-02-27

    Möbius strips are three-dimensional geometrical structures, fascinating for their peculiar property of being surfaces with only one "side"—or, more technically, being "nonorientable" surfaces. Despite being easily realized artificially, the spontaneous emergence of these structures in nature is exceedingly rare. Here, we generate Möbius strips of optical polarization by tightly focusing the light beam emerging from a q-plate, a liquid crystal device that modifies the polarization of light in a space-variant manner. Using a recently developed method for the three-dimensional nanotomography of optical vector fields, we fully reconstruct the light polarization structure in the focal region, confirming the appearance of Möbius polarization structures. The preparation of such structured light modes may be important for complex light beam engineering and optical micro- and nanofabrication. Copyright © 2015, American Association for the Advancement of Science.

  14. Spectrophotometric and Spectrofluorimetric Studies on Azilsartan Medoxomil and Chlorthalidone to be Utilized in Their Determination in Pharmaceuticals

    Directory of Open Access Journals (Sweden)

    Walid M. Ebeid

    2014-01-01

    Full Text Available The recently approved angiotensin II receptor blocker, azilsartan medoxomil (AZL, was determined spectrophotometrically and spectrofluorimetrically in its combination with chlorthalidone (CLT in their combined dosage form. The UV-spectrophotometric technique depends on simultaneous measurement of the first derivative spectra for AZL and CLT at 286 and 257 nm, respectively, in methanol. The spectrofluorimetric technique depends on measurement of the fourth derivative of the synchronous spectra intensities of AZL in presence of CLT at 298 nm in methanol. The effects of different solvents on spectrophotometric and spectrofluorimetric responses were studied. For, the spectrofluorimetric study, the effect of pH and micelle-assisted fluorescence enhancement were also studied. Linearity, accuracy, and precision were found to be satisfactory over the concentration ranges of 8-50 μg mL −1 and 2-20 μg mL −1 for AZL and CLT, respectively, in the spectrophotometric method as well as 0.01-0.08 μg mL −1 for AZL in the spectrofluorimetric method. The methods were successfully applied for the determination of the studied drugs in their co-formulated tablets. The developed methods are inexpensive and simple for the quality control and routine analysis of the cited drugs in bulk and in pharmaceuticals.

  15. Spectrophotometric determination of silica in water. Low range

    International Nuclear Information System (INIS)

    Acosta L, E.

    1992-07-01

    The spectrophotometric method for the determination of the silica element in water, demineralized water, raw waters, laundry waters, waters treated with ion exchange resins and sea waters is described. This method covers the determination of the silica element in the interval from 20 to 1000 μg/l on 50 ml. of base sample. These limits its can be variable if the size of the used aliquot one is changed for the final determination of the silica element. (Author)

  16. REM optical/NIR observations of MAXI J1659-152

    NARCIS (Netherlands)

    D'Avanzo, P.; Goldoni, P.; Patruno, A.; Casella, P.; Campana, S.; Russell, D.M.; Belloni, T.M.

    2010-01-01

    We observed the optical and NIR counterpart of the recently discovered X-ray transient MAXI J1659-152 (Negoro et al. 2010, ATel #2873; Mangano et al. 2010, GCN #11296) with the REM telescope located in La Silla (Chile) in imaging mode using the V, R, I, J, H and K filters.

  17. Alanine dosimetry using a spectrophotometric ferric-xylenol orange complex readout

    International Nuclear Information System (INIS)

    Laere, K. van; Buysse, J.; Berkvens, P.

    1989-01-01

    The spectrophotometric dosimetric method using the indirect oxidation of ferrous ions after dissolution of irradiated DL-and L-alanine has been thoroughly investigated with respect to its composition, read-out procedure and dose-response. Optimal concentration of 0.10 N H 2 SO 4 , 0.2 mM xylenol orange and 0.2 mM Fe 2+ were found, giving an absorption maximum at 547 nm. Standardization of chemical processing procedures allows a reproducibility better than 0.5%. The useful dose range has been extended to 0.03-12 kGy by means of slightly different read-out procedure. The quantitative concept of ''indirect yield'', G id , was introduced for this procedure as a measure of the indirect oxidation capacity of the radicals. It was found to be G id,0 (Fe 3+ ) 7.1 ions/100 eV transferred into the alanine. The spectrophotometric readout combines the highly advantageous use of alanine as a dosemeter with the straightforwardness, accuracy and low costs of the chemical procedure. (author)

  18. Espectrofotometria de longo caminho óptico em espectrofotômetro de duplo-feixe convencional: uma alternativa simples para investigações de amostras com densidade óptica muito baixa Long optical path length spectrophotometry in conventional double-beam spectrophotometers: a simple alternative for investigating samples of very low optical density

    Directory of Open Access Journals (Sweden)

    André Luiz Galo

    2009-01-01

    Full Text Available We describe the design and tests of a set-up mounted in a conventional double beam spectrophotometer, which allows the determination of optical density of samples confined in a long liquid core waveguide (LCW capillary. Very long optical path length can be achieved with capillary cell, allowing measurements of samples with very low optical densities. The device uses a custom optical concentrator optically coupled to LCW (TEFLON® AF. Optical density measurements, carried out using a LCW of ~ 45 cm, were in accordance with the Beer-Lambert Law. Thus, it was possible to analyze quantitatively samples at concentrations 45 fold lower than that regularly used in spectrophotometric measurements.

  19. Fast neutrons and the optical model: some observations

    International Nuclear Information System (INIS)

    Smith, A.B.; Lawson, R.D.; Guenther, P.T.

    1985-01-01

    The optical model of fast-neutron-induced phenomena is considered from the observational viewpoint. Experimental characteristics governing the reliability of the modeling are outlined with attention to implications on model parameters and their uncertainties. The physical characteristics of experimentally-deduced ''regional'' and ''specific'' model parameters are examined including: parameter trends with mass and energy, implications of collective effects, and fundamental relations between real and imaginary potentials. These physical properties are illustrated by studies in the A=60 and 90 regions. General trends are identified and outstanding issues cited. Throughout, the approach is that of observational interpretation for basic and applied purposes. 20 refs., 11 figs., 2 tabs

  20. Extractive spectrophotometric determination of thorium

    International Nuclear Information System (INIS)

    Venkatesan, M.; Gopalakrishnan, V.; Ramanujam, A.; Nadkarni, M.N.

    1981-01-01

    An extractive spectrophotometric method has been standardized for the analysis of 0.2 to 1.6 milligrams of thorium present in nitric acid solutions. The method involves the extraction of thorium from nitric acid solutions into 0.5 M thenoyl trifluoro acetone (HTTA) in benzene and its direct estimation from the organic extract by spectrophotometry as Thoron colour complex. In this method, interference due to iron upto 5 milligrams can be suppressed by adding ascorbic acid in the ratio of 1:2 prior to HTTA extraction. Uranium(VI) does not interefere even when present in 2000 times the amount of thorium. Plutonium and cerium do not interfere at one milligram level whereas zirconium interferes in this method. The overall error variation and precision of this method has been determined to be +- 3.5%. (author)

  1. The Selection and Protection of Optical Astronomical Observing Sites in China

    Science.gov (United States)

    Wenjing, Jin; Bai, Jinming; Yao, Yongqiang

    2015-03-01

    Before 1950 there are two observatories, Shanghai and Purple Mountain Astronomical Observatories (SHAO and PMO), and two observing stations, Qingdao and Kunming stations in China. With the requirements of astronomical research, two observatories, Beijing and Shaanxi Astronomical Observatories (BAO and SXAO) and two artificial satellite stations, Urumqi and Changchun, were established about 1960. Based on the current management, now there are 4 observatories, SHAO, PMO, NAOC(National Astronomical Observatories), which was grouped from BAO, YNAO and 2 others, as well as XAO (Xinjiang Astronomical Observatory). The optical 1-2 m class telescopes are being operated at former four observatories. SXAO is changed as National Time Service Center. Because of city expansion as well as the traveling and economic developments, these observatories are suffered severe light pollution. For example, Zo Ce is located at the suburb of Shanghai city. A 40 cm double astrograph was installed in 1900 and a 1.56 m optical reflector have been operated since November 1987. In 1994 the seeing is better than 1 and the night sky brightness in V is about 19 mag/arcsec 2, stars fainter than 20 mag with CCD are visibles. In 2007 a large playground was built in Zô Cè area. The light pollution is severe gradually. The night sky brightness has been increased to 15.8 mag/arcsec 2. The other observatories have similar situation. New site surveys and found new stations to solve the problem. Except the solar and radio stations of each Astronomical Observatory, now there are 3 optical observing sites at PMO (Hong-He, Xu-Yi and Yaoan), 2 at SHAO (Zô Cè and Tian Huang Ping) and 2 at YNAO (Kunming and Gao-Mei-Gu) as well as 1 optical observing site at BAO (Xing-Long). The best observing site is Gao-Mei-Gu, which is selected as the optical observing site of YNAO and where atmospheric turbulence distribution is 0.11 near ground with heights from 6.5m to 2.7m during night. Sky brightness in B and V band

  2. Development and Validation of Eco-Friendly Liquid Chromatographic and Spectrophotometric Methods for Simultaneous Determination of Coformulated Drugs: Phenylephrine Hydrochloride and Prednisolone Acetate.

    Science.gov (United States)

    Mostafa, Nadia M; Elsayed, Ghada M; Hassan, Nagiba Y; El Mously, Dina A

    2017-11-01

    Five simple, sensitive, and eco-friendly LC and UV spectrophotometric methods have been developed for the simultaneous determination of phenylephrine hydrochloride (PHE) and prednisolone acetate (PRD) in their combined dosage form. The first method was reversed-phase (RP) LC using methanol-water-heptane-1-sulfonic acid sodium salt (75 + 25 + 0.1, v/v/w) as a mobile phase. Separation was achieved using an XSelect HSS reversed-phase C18 analytical column (250 × 4.6 mm, 5µm). The flow rate was 1.0 mL/min and UV detection was done at 230 nm. Quantification was achieved over the concentration ranges of 5-50 µg/mL for PHE and 2-90 µg/mL for PRD. Four spectrophotometric methods were proposed, namely dual wavelength, first derivative of ratio spectra, ratio difference, and mean-centering of ratio spectra. Linearity was observed in the concentration ranges of 10-120 and 5-35 µg/mL for PHE and PRD, respectively, for the spectrophotometric methods. Green solvents were used in the proposed methods because they play a vital role in the analytical methods' influence on the environment. The suggested methods were validated regarding linearity, accuracy, and precision according to the International Conference on Harmonization guidelines, with satisfactory results. These methods could be used as harmless substitutes for routine analysis of the mentioned drugs, with no interference from excipients.

  3. Linking optical and infrared observations with gravitational wave sources through transient variability

    International Nuclear Information System (INIS)

    Stubbs, C W

    2008-01-01

    Optical and infrared observations have thus far detected more celestial cataclysms than have been seen in gravity waves (GW). This argues that we should search for gravity wave signatures that correspond to transient variables seen at optical wavelengths, at precisely known positions. There is an unknown time delay between the optical and gravitational transient, but knowing the source location precisely specifies the corresponding time delays across the gravitational antenna network as a function of the GW-to-optical arrival time difference. Optical searches should detect virtually all supernovae that are plausible gravitational radiation sources. The transient optical signature expected from merging compact objects is not as well understood, but there are good reasons to expect detectable transient optical/IR emission from most of these sources as well. The next generation of deep wide-field surveys (for example PanSTARRS and LSST) will be sensitive to subtle optical variability, but we need to fill the 'blind spots' that exist in the galactic plane, and for optically bright transient sources. In particular, a galactic plane variability survey at λ∼ 2 μm seems worthwhile. Science would benefit from closer coordination between the various optical survey projects and the gravity wave community

  4. Determination of cyanide by a highly sensitive indirect spectrophotometric method.

    Science.gov (United States)

    Blanco, M; Maspoch, S

    1984-01-01

    Complexation of Pd(2+) with cyanide inhibits the extraction of the palladium complex of 5-phenylazo-8-aminoquinoline. This effect is used for the indirect spectrophotometric determination of cyanide at the mug level. Cyanide in industrial waste water and in sea-water is determined after distillation as HCN from the sample and collection in sodium hydroxide solution.

  5. Spectrophotometric investigation into iodine-electron donor systems at low temperature

    International Nuclear Information System (INIS)

    Gorodyskij, V.A.; Morachevskij, A.A.

    1978-01-01

    Iodine-sec. butanol (n-donor) and iodine - hexene - 1 (π-donor) have been investigated for the first time by the spectrophotometric method in the wide temeprature range (77-293 K). The existence of complexes with a charge transfer of the type, which is characterized by the long-wave absorption band in electron spectra, is determined in the systems

  6. Data Fusion Based on Optical Technology for Observation of Human Manipulation

    Science.gov (United States)

    Falco, Pietro; De Maria, Giuseppe; Natale, Ciro; Pirozzi, Salvatore

    2012-01-01

    The adoption of human observation is becoming more and more frequent within imitation learning and programming by demonstration approaches (PbD) to robot programming. For robotic systems equipped with anthropomorphic hands, the observation phase is very challenging and no ultimate solution exists. This work proposes a novel mechatronic approach to the observation of human hand motion during manipulation tasks. The strategy is based on the combined use of an optical motion capture system and a low-cost data glove equipped with novel joint angle sensors, based on optoelectronic technology. The combination of the two information sources is obtained through a sensor fusion algorithm based on the extended Kalman filter (EKF) suitably modified to tackle the problem of marker occlusions, typical of optical motion capture systems. This approach requires a kinematic model of the human hand. Another key contribution of this work is a new method to calibrate this model.

  7. Sensitization of glycine (spectrophotometric read-out) dosimetric system using sorbitol

    International Nuclear Information System (INIS)

    Shinde, S.H.; Mukherjee, T.

    2009-01-01

    Glycine spectrophotometric read-out systems have a useful dose range of 15-4000 Gy. An attempt was made to sensitize it using sorbitol as a sensitizer. Optimum compositions of aqueous acidic solutions of ferrous ammonium sulphate-xylenol orange (XO), i.e. FX and sorbitol-ferrous ammonium sulphate-xylenol orange, i.e. SFX, for 400 mg of glycine, which gives maximum dosimetric response for any given dose, were established. Molar absorption coefficient values of ferric-XO-glycine complex, i.e. ε-values, were determined for glycine system in FX and SFX. These values were found to be 8410 and 15,000 m 2 mol -1 respectively, indicating that an enhancement or sensitivity factor of about 1.78 can be achieved by sorbitol for glycine in SFX. This factor was further confirmed by measuring the gamma dose response of glycine in FX and in SFX for four different doses, viz. 37.8, 75.5, 151 and 302 Gy. It was observed that dose response of glycine in SFX is about 77% more than that of glycine in FX. The maximum variation observed in response of glycine in FX or SFX was found to be within ±1.5%.

  8. Astronomical observations with the optical multichannel analyser of the Sao Paulo University

    Energy Technology Data Exchange (ETDEWEB)

    Codina-Landaberry, S J; de Freitas Pacheco, J A [Universidade Mackenzie, Sao Paulo (Brazil). Centro de Radio-Astronomia e Astrofisica

    1979-03-01

    The first astronomical observations made with the optical multichannel analyser (OMA) of the Sao Paulo University is reported. A detailed description of the instrumentation is given as well as the results derived from the observation of some emission nebulae.

  9. Spectrophotometric determination of procainamide hydrochloride using sodium periodate

    OpenAIRE

    Al-Tamrah, S.; Al-Abbad, S.

    2015-01-01

    A simple spectrophotometric method has been described for the determination of procainamide hydrochloride. The method is based on the oxidation of procainamide hydrochloride by sodium periodate in the presence of sulfuric acid and measurement of the absorbance of the violet color formed at 531 nm. Parameters affecting the reaction were studied and conditions were optimized. Linear calibration graph was obtained from 50 to 700 μg ml−1 of procainamide hydrochloride and the limit of detection wa...

  10. Measurements of Saharan dust aerosols over the Eastern Mediterranean using elastic backscatter-Raman lidar, spectrophotometric and satellite observations in the frame of the EARLINET project

    Directory of Open Access Journals (Sweden)

    A. Papayannis

    2005-01-01

    Full Text Available We report on the vertical distributions of Saharan dust aerosols over the N.E. Mediterranean region, which were obtained during a typical dust outbreak on August 2000, by two lidar systems located in Athens and Thessaloniki, Greece, in the frame of the European EARLINET project. MODIS and ground sun spectrophotometric data, as well as air-mass backward trajectories confirmed the existence of Saharan dust in the case examined, which was also successfully forecasted by the DREAM dust model. The lidar data analysis for the period 2000-2002 made possible, for the first time, an estimation of the vertical extent of free tropospheric dust layers [mean values of the aerosol backscatter and extinction coefficients and the extinction-to-backscatter ratio (lidar ratio, LR at 355 nm], as well as a seasonal distribution of Saharan dust outbreaks over Greece, under cloud-free conditions. A mean value of the lidar ratio at 355 nm was obtained over Athens (53±1 sr and over Thessaloniki (44±2 sr during the Saharan dust outbreaks. The corresponding aerosol optical thickness (AOT at 355 nm, in the altitude range 0-5 km, was 0.69±0.12 and 0.65±0.10 for Athens and Thessaloniki, respectively (within the dust layer the AOT was 0.23 and 0.21, respectively. Air-mass back-trajectory analysis performed in the period 2000-2002 for all Saharan dust outbreaks over the N.E. Mediterranean indicated the main pathways followed by the dust aerosols.

  11. Astronomical observations with the optical multichannel analyser of the Sao Paulo University

    International Nuclear Information System (INIS)

    Codina-Landaberry, S.J.; Freitas Pacheco, J.A. de

    1979-01-01

    The first astronomical observations made with the optical multichannel analyser (OMA) of the Sao Paulo University is reported. A detailed description of the instrumentation is given as well as the results derived from the observation of some emission nebulae [pt

  12. Optical telescope BIRT in ORIGIN for gamma ray burst observing

    DEFF Research Database (Denmark)

    Content, Robert; Content, Robert; Sharples, Ray

    2012-01-01

    The ORIGIN concept is a space mission with a gamma ray, an X-ray and an optical telescope to observe the gamma ray bursts at large Z to determine the composition and density of the intergalactic matter in the line of sight. It was an answer to the ESA M3 call for proposal. The optical telescope i...... length. All 3 instruments use the same 2k x 2k detector simultaneously so that telescope pointing and tip-tilt control of a fold mirror permit to place the gamma ray burst on the desired instrument without any other mechanism. © 2012 SPIE....

  13. Optical properties of Sulfur doped InP single crystals

    Science.gov (United States)

    El-Nahass, M. M.; Youssef, S. B.; Ali, H. A. M.

    2014-05-01

    Optical properties of InP:S single crystals were investigated using spectrophotometric measurements in the spectral range of 200-2500 nm. The absorption coefficient and refractive index were calculated. It was found that InP:S crystals exhibit allowed and forbidden direct transitions with energy gaps of 1.578 and 1.528 eV, respectively. Analysis of the refractive index in the normal dispersion region was discussed in terms of the single oscillator model. Some optical dispersion parameters namely: the dispersion energy (Ed), single oscillator energy (Eo), high frequency dielectric constant (ɛ∞), and lattice dielectric constant (ɛL) were determined. The volume and the surface energy loss functions (VELF & SELF) were estimated. Also, the real and imaginary parts of the complex conductivity were calculated.

  14. Thorium spectrophotometric analysis with high precision

    International Nuclear Information System (INIS)

    Palmieri, H.E.L.

    1983-06-01

    An accurate and precise determination of thorium is proposed. Precision of about 0,1% is required for the determination of macroquantities of thorium processed. After an extensive literature search concerning this subject, spectrophotometric titration has been chosen, using disodium ethylenediaminetetraacetate (EDTA) solution and alizarin S as indicator. In order to obtain such a precision, an amount of 0,025 M EDTA solution precisely measured has been added and the titration was completed with less than 5 ml of 0,0025 M EDTA solution. It is usual to locate the end-point graphically, by plotting added titrant versus absorbance. The non-linear minimum square fit, using the Fletcher e Powell's minimization process and a computer program. (author)

  15. Construção de uma cela de fluxo de longo caminho óptico para medidas espectrofotométricas Construction of a long-pathlength flow cell for spectrophotometric measurements

    Directory of Open Access Journals (Sweden)

    Wanessa Roberto Melchert

    2008-01-01

    Full Text Available A simple and low-cost flow cell with 30 cm optical path for spectrophotometric measurements is described. It presents desirable characteristics such as low attenuation of the radiation beam and internal volume (75 µL comparable to that of a 1-cm conventional cell (80 µL. Despite the increase in optical path, the effect on sample dispersion was also similar to that attained in the commercial cell. The performance of the cell was assessed by the determination of phosphate based on the molybdenum blue method, yielding a linear response range between 0.05 and 0.8 mg L-1 phosphorus (r=0.999. The increase in sensitivity (30.4-fold in comparison with that obtained with a conventional 1-cm flow cell agreed with that estimated by the Lambert-Beer law.

  16. Verification of spectrophotometric method for nitrate analysis in water samples

    Science.gov (United States)

    Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu

    2017-12-01

    The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.

  17. SPECTROPHOTOMETRIC, ATOMIC ABSORPTION AND CONDUCTOMETRIC ANALYSIS OF TRAMADOL HYDROCHLORIDE

    Directory of Open Access Journals (Sweden)

    Sara M. Anis

    2011-09-01

    Full Text Available Six simple and sensitive spectroscopic and conductometric procedures (A-F were developed for the determination of tramadol hydrochloride. Methods A, B and C are based on the reaction of cobalt (II thiocyanate with tramadol to form a stable ternary complex, which could be measured by spectrophotometric (method A, atomic absorption (method B or conductometric (method C procedures. Methods D and E depend on the reaction of molybdenum thiocyanate with tramadol to form a stable ternary complex, measured by spectrophotometric means (method D or by atomic absorption procedures (method E, while method F depends on the formation of an ion pair complex between the studied drug and bromothymol blue which is extractable into methylene chloride. Tramadol hydrochloride could be assayed in the range of 80-560 and 40-–220 μg ml-1, 1-15 mg ml-1 and 2.5-22.5, 1.25-11.25 and 5-22 μg ml-1 using methods A,B,C,D,E and F, respectively. Various experimental conditions were studied. The results obtained showed good recoveries. The proposed procedures were applied successfully to the analysis of tramadol in its pharmaceutical preparations and the results were favorably comparable with the official method.

  18. Spectrophotometric determination of trace uranium in phosphate ore samples from kurum and uro areas, Nuba mountains, Sudan

    International Nuclear Information System (INIS)

    Mohamed, A. A.; Ali, A. H.; Altayeb, M. A. H.

    2004-01-01

    A method was proposed for the spectrophotometric determination of uranium content in phosphate ores. the method is based on the use of nitrogen (v) acid for leaching the rock, and treatment with ammonium carbonate solution, whereby uranium (Vi) is kept in solution as its carbonate complex. The ion-exchange technique was used for the recovery of uranium. Uranium was determined spectrophotometrically by measurement of the absorbance of the yellow uranium (Vi)-8-hydroxyquinolate complex at λ 425 nm. The procedure was used for the determination of trace uranium content in 30 phosphate ore samples collected from Kurun and Uro areas in Nuba mountains in Sudan. X-ray fluorescence technique was employed for the assessment of the method used. The spectrophotometric method results show a high similarity with those obtained by XRF technique. This agreement indicates that the procedure proposed here has been successfully applied for the determination of uranium in phosphate ores. (Author)

  19. The high resolution optical instruments for the Pleiades HR Earth observation satellites

    Science.gov (United States)

    Gaudin-Delrieu, Catherine; Lamard, Jean-Luc; Cheroutre, Philippe; Bailly, Bruno; Dhuicq, Pierre; Puig, Olivier

    2017-11-01

    Coming after the SPOT satellites series, PLEIADESHR is a CNES optical high resolution satellite dedicated to Earth observation, part of a larger optical and radar multi-sensors system, ORFEO, which is developed in cooperation between France and Italy for dual Civilian and Defense use. The development of the two PLEIADES-HR cameras was entrusted by CNES to Thales Alenia Space. This new generation of instrument represents a breakthrough in comparison with the previous SPOT instruments owing to a significant step in on-ground resolution, which approaches the capabilities of aerial photography. The PLEIADES-HR instrument program benefits from Thales Alenia Space long and successful heritage in Earth observation from space. The proposed solution benefits from an extensive use of existing products, Cannes Space Optics Centre facilities, unique in Europe, dedicated to High Resolution instruments. The optical camera provides wide field panchromatic images supplemented by 4 multispectral channels with narrow spectral bands. The optical concept is based on a four mirrors Korsch telescope. Crucial improvements in detector technology, optical fabrication and electronics make it possible for the PLEIADES-HR instrument to achieve the image quality requirements while respecting the drastic limitations of mass and volume imposed by the satellite agility needs and small launchers compatibility. The two flight telescopes were integrated, aligned and tested. After the integration phase, the alignment, mainly based on interferometric measurements in vacuum chamber, was successfully achieved within high accuracy requirements. The wave front measurements show outstanding performances, confirmed, after the integration of the PFM Detection Unit, by MTF measurements on the Proto-Flight Model Instrument. Delivery of the proto flight model occurred mi-2008. The FM2 Instrument delivery is planned Q2-2009. The first optical satellite launch of the PLEIADES-HR constellation is foreseen

  20. Spectrophotometric determination of thorium using arsenazo III in water

    International Nuclear Information System (INIS)

    Rio, M.A.P. do; Godoy, J.M. de.

    1985-01-01

    A spectrophotometric determination of thorium with arsenazo III (1,8 dihidroxynaphtaline - 3,6 sulfanic acid - 2,7 bis (azo-2) - phenil argonic acid) was carried out aiming to analyse this element in water. In order to eliminate possible interferences, a coprecipitation with lantanium fluoride was used followed by an extration with 0,2 M TTA (tenoil-trifluor - aceton) / Benzen. The results showed a good agreement with the ones obtained by alfa-spectrometry. (Author) [pt

  1. Spectrophotometric determination of dopaminergic drugs used for Parkinson's disease, cabergoline and ropinirole, in pharmaceutical preparations.

    Science.gov (United States)

    Onal, Armağan; Cağlar, Sena

    2007-04-01

    Simple and reproducible spectrophotometric methods have been developed for determination of dopaminergic drugs used for Parkinson's disease, cabergoline (CAB) and ropinirole hydrochloride (ROP), in pharmaceutical preparations. The methods are based on the reactions between the studied drug substances and ion-pair agents [methyl orange (MO), bromocresol green (BCG) and bromophenol blue (BPB)] producing yellow colored ion-pair complexes in acidic buffers, after extracting in dichloromethane, which are spectrophotometrically determined at the appropriate wavelength of ion-pair complexes. Beer's law was obeyed within the concentration range from 1.0 to 35 microg ml(-1). The developed methods were applied successfully for the determination of these drugs in tablets.

  2. Multi-conjugate adaptive optics observations of the Orion Trapezium Cluster

    International Nuclear Information System (INIS)

    Petr-Gotzens, M G; Kolb, J; Marchetti, E; Sterzik, M F; Ivanov, V D; Nuernberger, D; Koehler, R; Bouy, H; MartIn, E L; Huelamo, N; Navascues, D Barrado y

    2008-01-01

    We obtained very deep and high spatial resolution near-infrared images of the Orion Trapezium Cluster using the Multi-Conjugate Adaptive Optics Demonstrator (MAD) instrument at the VLT. The goal of these observations has been to search for objects at the very low-mass end of the IMF down to the planetary-mass regime. Three fields in the innermost dense part of the Trapezium Cluster, with a total area of 3.5 sq.arcmin have been surveyed at 1.65μm and 2.2μm. Several new candidate planetary mass objects with potential masses Jup have been detected based on their photometry and on their location in the colour-magnitude diagram. The performance of the multi-conjugate adaptive optics correction is excellent over a large field-of-view of ∼ 1'. The final data has a spatial resolution of Jup ), however, must await future confirmation by spectroscopic and/or photometric observations.

  3. Spectrophotometric flow-injection analysis assay of tetracycline antibiotics using a dual light-emitting diode based detector

    Directory of Open Access Journals (Sweden)

    Prinya Masawat

    2008-02-01

    Full Text Available In this paper, a small dual light-emitting diode (LED-based detector for FIA process analyser has been designed. The detector’s optical parts comprise a flow-through cell, a dual-blue LED and a photodiode. Neither mirrors nor lenses are used. The optical path for the first LED detects the blank, while the other LED detects the sample. The detector’s electronic components including a signal amplifier and an A/D converter are integrated on one small board connected to a PC for measuring the results. The designed spectrophotometric detector was used for the determination of tetracycline antibiotics. Uranyl acetate was used as a reagent forming orange-red complexes with the drugs in N,N– dimethylformamide. The complexes show absorption maxima at 410, 416 and 408 nm for tetracycline hydrochloride (TCH, chlortetracycline hydrochloride (CTCH, and doxycycline hydrochloride (DCH, respectively. The detection limit was found to be 0.38, 0.75, 1.44 µg mL-1 and the linear range was obtained at 1.0-3.0, 3.0-5.0, and 3.0-10.0 µg mL-1 for TCH, CTCH and DCH, respectively. The proposed method has been successfully applied to the determination of tetracycline antibiotic residues in milk samples. Moreover, this method is an environmentally friendly approach and suitable for routine analysis.

  4. AAS and spectrophotometric determination of propranolol HCl and metoprolol tartrate.

    Science.gov (United States)

    El-Ries, M A; Abou Attia, F M; Ibrahim, S A

    2000-12-15

    Two simple and accurate spectrophotometric methods are described for the determination of propranolol hydrochloride (I) and metoprolol tartrate (II). The methods are based on the reaction of each drug as a secondary amine: (a) with carbon disulphide, the formed complex extracted into iso-butyl methyl ketone (IBMK) after chelation with Cu(II) ions at pH 7.5, followed by measuring the absorbance at 435.4 nm or indirectly for the drug by flame atomic absorption spectrophotometry (AAS). The calibration graph is linear up to 40 and 60 microg ml(-1) with apparent molar absorptivities of 6.89 x 10(3) and 1.08 x 104 l mol(-1) cm(-1) and correlation coefficients of 0.9994 and 0.9995 for propranolol and metoprolol, respectively; (b) with pi-acceptors, tetracyanoethylene (TCNE), or chloranilic acid (CLA) to give highly coloured complex species. The coloured products are quantitated spectrophotometrically at 415 or 510 nm for the two drugs with TCNE and CLA, respectively, and obey Beer's Law with RSD less than 2.0. The methods were applied to the determination of these drugs in pharmaceutical preparation without interferences.

  5. High Resolution Active Optics Observations from the Kepler Follow-up Observation Program

    Science.gov (United States)

    Gautier, Thomas N.; Ciardi, D. R.; Marcy, G. W.; Hirsch, L.

    2014-01-01

    The ground based follow-up observation program for candidate exoplanets discovered with the Kepler observatory has supported a major effort for high resolution imaging of candidate host stars using adaptive optics wave-front correction (AO), speckle imaging and lucky imaging. These images allow examination of the sky as close as a few tenths of an arcsecond from the host stars to detect background objects that might be the source of the Kepler transit signal instead of the host star. This poster reports on the imaging done with AO cameras on the Keck, Palomar 5m and Shane 3m (Lick Observatory) which have been used to obtain high resolution images of over 500 Kepler Object of Interest (KOI) exoplanet candidate host stars. All observations were made at near infrared wavelengths in the J, H and K bands, mostly using the host target star as the AO guide star. Details of the sensitivity to background objects actually attained by these observations and the number of background objects discovered are presented. Implications to the false positive rate of the Kepler candidates are discussed.

  6. Determination of the acidity constants of neutral red and bromocresol green by solution scanometric method and comparison with spectrophotometric results

    Directory of Open Access Journals (Sweden)

    Ardeshir Shokrollahi

    2016-03-01

    The method is based on scanning cells containing the indicator solution with a scanner, and analyzing the color of each cell with a software written in visual basic (VB 6 media to red, green and blue values. The cells were made by making holes in the Plexiglas® sheet. Also, the acidity constants of the neutral red and bromocresol green indicators were studied with spectrophotometrically. HypSpec program has been applied for the estimation of pKa values based on spectrophotometric data. The agreement between obtained pKa values by solution scanometric, spectrophotometric method and values reported in the literature demonstrates the utility of the method here used. Also the HySS 2009 program was applied for drawing of the corresponding distribution diagrams.

  7. Electrical and optical properties of gold nanoparticles: applications in gold nanoparticles-cholesterol oxidase integrated systems for cholesterol sensing

    Energy Technology Data Exchange (ETDEWEB)

    Saxena, Urmila; Goswami, Pranab, E-mail: pgoswami@iitg.ernet.in [Indian Institute of Technology Guwahati, Department of Biotechnology (India)

    2012-03-15

    We describe here the application of electrical and optical properties of gold nanoparticles (AuNPs) in conjunction with cholesterol oxidase (ChOx) for cholesterol estimation. The electrocatalytic property of AuNPs was studied with spectrophotometric technique using a redox dye 2,6-dichloroindophenol (DCPIP), where AuNPs found to increase the electron transfer rate between ChOx and DCPIP by {approx}1.68-fold. This study demonstrated AuNPs as efficient electron transfer mediator for ChOx based electrochemical cholesterol biosensors. Optocatalytic property of AuNPs was used in the AuNPs seed mediated enlargement system to develop an optical detection path for cholesterol. This optical method exhibited a linear detection range of 0.01-0.1 mM and a detection limit of 10 {mu}M cholesterol. The effect of AuNPs size (13-21 nm) on the catalytic properties of AuNPs was also studied. Spectrophotometric analysis of the electron transfer process between ChOx and DCPIP with different sized AuNPs showed highest electron transfer efficiency with smaller (13 nm) AuNPs. The electrochemical bioelectrode fabricated with AuNPs and ChOx gave consensus results. Contrastingly, AuNPs size did not affect its optocatalytic activity and eventually the performance of the optical method based on the growth of AuNPs. The findings of the present study offer useful insight and perspectives for fabricating highly sensitive analytical systems based on AuNPs-ChOx complexes.

  8. Different Spectrophotometric and Chromatographic Methods for Determination of Mepivacaine and Its Toxic Impurity.

    Science.gov (United States)

    Abdelwahab, Nada S; Fared, Nehal F; Elagawany, Mohamed; Abdelmomen, Esraa H

    2017-09-01

    Stability-indicating spectrophotometric, TLC-densitometric, and ultra-performance LC (UPLC) methods were developed for the determination of mepivacaine HCl (MEP) in the presence of its toxic impurity, 2,6-dimethylanaline (DMA). Different spectrophotometric methods were developed for the determination of MEP and DMA. In a dual-wavelength method combined with direct spectrophotometric measurement, the absorbance difference between 221.4 and 240 nm was used for MEP measurements, whereas the absorbance at 283 nm was used for measuring DMA in the binary mixture. In the second-derivative method, amplitudes at 272.2 and 232.6 nm were recorded and used for the determination of MEP and DMA, respectively. The developed TLC-densitometric method depended on chromatographic separation using silica gel 60 F254 TLC plates as a stationary phase and methanol-water-acetic acid (9 + 1 + 0.1, v/v/v) as a developing system, with UV scanning at 230 nm. The developed UPLC method depended on separation using a C18 column (250 × 4.6 mm id, 5 μm particle size) as a stationary phase and acetonitrile-water (40 + 60, v/v; pH 4 with phosphoric acid) as a mobile phase at a flow rate of 0.4 mL/min, with UV detection at 215 nm. The chromatographic run time was approximately 1 min. The proposed methods were validated with respect to International Conference on Harmonization guidelines regarding precision, accuracy, ruggedness, robustness, and specificity.

  9. Estimating Soil and Vegetation Parameters using Synergies between Optical and Microwave Observations

    Science.gov (United States)

    Timmermans, J.; Gomez-Dans, J. L.; Lewis, P.; Loew, A.; Schlenz, F.; Mathieu, P. P.; Pounder, N. L.; Styles, J.

    2017-12-01

    The large amount of remote sensing data available provides a huge potential for various applications, such as crop monitoring. This potential has not been realized yet because inversion-algorithms mostly use a single sensor approach. Consequently, products that combine different low-level observations from different sensors are hard to find. The difficulty in a multi-sensor approach is that 1) different sensor types (microwave/ optical) require different radiative transfer (RT) models and 2) it require consistency between the models. The goal of this research was to investigate the synergistic potential of integrating optical (Opt) and passive microwave (PM) RT models within the Earth Observation Land Data Assimilation System (EOLDAS). EOLDAS uses a Bayesian data assimilation approach together with observation operators such as PROSAIL to estimate state variables. In order to use PM observations, the Community Microwave Emission Model was integrated into the system. Results show a high potential when both Opt and PM observations are used independently. Using only RapidEye only with SAIL RT model, LAI was estimated with R=0.68, with leaf water content and dry matter having lower correlations |R|<0.4. Results for retrieving soil temperature and leaf area index retrievals using only Elbarra observations were good with respectively R=[0.85, 0.79], and for soil moisture also very good with R=0.73 (focusing on dry-spells of at least 9 days only), and with R=0.89 and R=0.77 for respectively the trend and anomalies. Synergistically using Opt and MW observations also shows good potential. Results show that absolute errors decreased (with RMSE=1.22 and S=0.89), but with lower R=0.59; sparse optical observations only improved part of the temporal domain. This shows that PM observations provide good information for the overall trend of the retrieved LAI due to the regular acquisitions, while Opt observations provides better information of the absolute values of the LAI.

  10. Complexation equilibria and spectrophotometric determination of iron(III) with 1-amino-4-hydroxyanthraquinone.

    Science.gov (United States)

    Abu-Bakr, M S; Sedaira, H; Hashem, E Y

    1994-10-01

    The complex equilibria of iron(III) with 1-amino-4-hydroxyanthraquinone (AMHA) were studied spectrophotometrically in 40% (v/v) ethanol and an ionic strength of 0.1M (NaClO(4)). The complexation reactions were demonstrated and characterized using graphical logarithmic analysis of the absorbance-pH graphs. A simple, rapid, selective and sensitive method for the spectrophotometric determination of trace amounts of Fe(III) is developed based on the formation of Fe(AMHA) complex at pH 2.5 (lambda(max) = 640 nm, epsilon approximately = 2.1 x 10(4) L. mol(-1) . cm(-1)) in the presence of a large number of foreign ions. Interferences caused by palladium(II) was masked by the addition of cyanide ions. The method has been applied to the determination of iron in some synthetic samples and polymetallic iron ores.

  11. Spectrophotometric Determination of Zinc Using 7-(4-Nitrophenylazo-8-Hydroxyquinoline-5-Sulfonic Acid

    Directory of Open Access Journals (Sweden)

    Korn Maria das Graças Andrade

    1999-01-01

    Full Text Available A sensitive and selective spectrophotometric method is proposed for the rapid determination of zinc(II using an 8-hydroxyquinoline derivative, 7-(4-nitrophenylazo-8-hydroxyquinoline-5-sulfonic acid (p-NIAZOXS, as a new spectrophotometric reagent. The reaction between the p-NIAZOXS and zinc(II is instantaneous at pH 9.2 (borax buffer and the absorbance remains stable for over 24 h. The method allows the determination of zinc over the range of 0.05-1.0 mug mL-1 with a molar absorptivity of 3.75x10(4 L mol-1 cm-1 and features a detection limit of 15 ng mL-1. The proposed method has been successfully applied to the determination of zinc in several pharmaceutical preparations and copper alloys. The precision (R.S.D. < 2% and the accuracy obtained were satisfactory.

  12. Multi-wavelength spectrophotometric analysis for detection of xanthochromia in cerebrospinal fluid and accuracy for the diagnosis of subarachnoid hemorrhage.

    Science.gov (United States)

    Smith, Andrew; Wu, Alan H B; Lynch, Kara L; Ko, Nerissa; Grenache, David G

    2013-09-23

    Cerebrospinal fluid (CSF) was examined for bilirubin, an important indicator for diagnosis of subarachnoid hemorrhage (SAH). A multi-wavelength (340, 415, and 460 nm) spectrophotometric assay was developed for the quantitative measurement of bilirubin in CSF, enabling the mathematical correction for absorbance of hemoglobin and proteins. Bilirubin and hemoglobin results were correlated to HPLC and a standard colorimetric assay, respectively. A subset of samples was sent for an absorbance reading at 450 nm following baseline correction. The multi-wavelength bilirubin assay was validated on 70 patients with confirmed SAH and 70 patients with neurologic symptoms who ruled out for SAH. The multi-wavelength spectrophometric assay demonstrated no interferences due to proteins (albumin) up to 30 g/l or oxyhemoglobin up to 260 mg/l. The assay limit of detection was 0.2 mg/l, linear to 20 mg/l, and CVs ranged from 1 to 6% at bilirubin concentrations of 0.84 and 2.1mg/l. The spectrophotometric assay correlated to HPLC and the colorimetric assay for bilirubin and hemoglobin, respectively. Results also correlated to the absorbance method (with removal of samples with high hemoglobin and proteins). The area under the ROC curve for diagnosis of SAH was 0.971 and 0.954 for the HPLC and spectrophotometric assay, respectively. At a cutoff of 0.2mg/l, the clinical specificity was 100% for both assays, and the clinical sensitivity was 94.3% and 88.6% for SAH for the HPLC and spectrophotometric asays, respectively. The multi-wavelength spectrophotometric assay is an objective alternative to visual inspection, HPLC, and absorbance for CSF bilirubin. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Zeolite - a possible substitute of silica gel in spectrophotometric determination of uranium?

    International Nuclear Information System (INIS)

    Foeldesova, M; Dillinger, P.

    2006-01-01

    Zeolites sorption abilities differ from the ones of the silica gel, which is normally used for uranium determination by spectrophotometric method. The difference is obvious mainly in the case of zeolites chemically modified with 1 or 2 mol/L NaOH solution. Absorbances measured using these zeolites on an radioactive water samples were 4 to 4.2 times bigger than the ones with silica gel. This avoids a use of one universal calibration curve for experimental data evaluation. Within delivered experimental data only a calibration curve for silica gel was provided. Its application to zeolites caused substantial misinterpretation of the results. Calculational construction of individual calibration curves made at this work shaw, that zeolites have a potential to replace the silica gel. This possibility is necessary to confirm by more experiments. Better sorption abilities of the modified zeolites would be utilized to reduce the lower limit for uranium determination by spectrophotometric method. (authors)

  14. Liquid chromatographic and ultraviolet spectrophotometric determination of bevantolol and hydrochlorothiazide in feeds.

    Science.gov (United States)

    Spurlock, C H; Schneider, H G

    1984-01-01

    Separate assay methods have been developed for the 2 components of an 80 + 20 drug blend of bevantolol and hydrochlorothiazide (HCT) in admixtures with animal feed. Drug/diet admixtures are extracted with methanol for reverse phase ion-pair liquid chromatographic (LC) assay of bevantolol, and with acetonitrile for ultraviolet spectrophotometric assay of HCT. Bevantolol, a cardioselective beta blocker, is separated from soluble feed components with an RP-18 column, using methanol-water-acetic acid (60 + 40 + 1) containing 0. 005M octane-sulfonic acid, sodium salt, as ion-pairing reagent. HCT is determined spectrophotometrically in acetonitrile extracts, using a suitable blank extract as reference. Average recovery of HCT from an admixture of 0.5 mg blend/g diet is 94.5% +/- 4.3 RSD and at 2.0 mg/g, 101.5% +/- 3.5 RSD. Bevantolol recovery from the same admixtures is 101.8% +/- 2.7 RSD and 99.0% +/- 3.5 RSD, respectively, using the method as described.

  15. Comparative study on the selectivity of various spectrophotometric techniques for the determination of binary mixture of fenbendazole and rafoxanide.

    Science.gov (United States)

    Saad, Ahmed S; Attia, Ali K; Alaraki, Manal S; Elzanfaly, Eman S

    2015-11-05

    Five different spectrophotometric methods were applied for simultaneous determination of fenbendazole and rafoxanide in their binary mixture; namely first derivative, derivative ratio, ratio difference, dual wavelength and H-point standard addition spectrophotometric methods. Different factors affecting each of the applied spectrophotometric methods were studied and the selectivity of the applied methods was compared. The applied methods were validated as per the ICH guidelines and good accuracy; specificity and precision were proven within the concentration range of 5-50 μg/mL for both drugs. Statistical analysis using one-way ANOVA proved no significant differences among the proposed methods for the determination of the two drugs. The proposed methods successfully determined both drugs in laboratory prepared and commercially available binary mixtures, and were found applicable for the routine analysis in quality control laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Remote online process measurements by a fiber optic diode array spectrometer

    International Nuclear Information System (INIS)

    Van Hare, D.R.; Prather, W.S.; O'Rourke, P.E.

    1986-01-01

    The development of remote online monitors for radioactive process streams is an active research area at the Savannah River Laboratory (SRL). A remote offline spectrophotometric measurement system has been developed and used at the Savannah River Plant (SRP) for the past year to determine the plutonium concentration of process solution samples. The system consists of a commercial diode array spectrophotometer modified with fiber optic cables that allow the instrument to be located remotely from the measurement cell. Recently, a fiber optic multiplexer has been developed for this instrument, which allows online monitoring of five locations sequentially. The multiplexer uses a motorized micrometer to drive one of five sets of optical fibers into the optical path of the instrument. A sixth optical fiber is used as an external reference and eliminates the need to flush out process lines to re-reference the spectrophotometer. The fiber optic multiplexer has been installed in a process prototype facility to monitor uranium loading and breakthrough of ion exchange columns. The design of the fiber optic multiplexer is discussed and data from the prototype facility are presented to demonstrate the capabilities of the measurement system

  17. Liquid–liquid microextraction in a multicommuted flow system for direct spectrophotometric determination of iodine value in biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Andréia C.; Rocha, Fábio R.P., E-mail: frprocha@cena.usp.br

    2014-06-01

    Highlights: • First flow-based procedure for iodine value determination in biodiesel. • Simple, fast and reliable procedure. • Detection without sample pretreatment or phase separation. • Liquid–liquid microextraction with low sample and reagent volumes. • Avoid toxic reagents and organic solvent used in the reference procedure. Abstract: A flow-based procedure was developed for the direct spectrophotometric determination of the iodine value (IV) in biodiesel. The procedure was based on the microextraction/reaction of unsaturated compounds with triiodide ions in an aqueous medium by inserting the reagent solution between the aliquots of biodiesel without any pretreatment. The interaction occurred through the biodiesel film formed on the inner walls of the hydrophobic tube used as the reactor and at the aqueous/biodiesel interfaces. The spectrophotometric detection was based on the discoloration of the I₃⁻ reagent in the aqueous phase by using a glass tube coupled to a fiber-optic spectrophotometer as the detection cell. Reference solutions were prepared by dilution of biodiesel samples with previously determined IV in hexane. The analytical response was linear for IV from 13 to 135 g I₂/100 g with a detection limit of 5 g I₂/100 g. A coefficient of variation of 1.7% (n = 10) and a sampling rate of 108 determinations per hour were achieved by consuming 224 μL of the sample and 200 μg of I₂ per determination. The slopes of analytical curves obtained with three different biodiesel samples were in agreement (variations in slopes lower than 3.1%), thus indicating an absence of any matrix effects. Results for biodiesel samples from different sources agreed with the volumetric official procedure at the 95% confidence level. The proposed procedure is therefore a simple, fast, and reliable alternative for estimating the iodine value of biodiesel.

  18. Liquid–liquid microextraction in a multicommuted flow system for direct spectrophotometric determination of iodine value in biodiesel

    International Nuclear Information System (INIS)

    Pereira, Andréia C.; Rocha, Fábio R.P.

    2014-01-01

    Highlights: • First flow-based procedure for iodine value determination in biodiesel. • Simple, fast and reliable procedure. • Detection without sample pretreatment or phase separation. • Liquid–liquid microextraction with low sample and reagent volumes. • Avoid toxic reagents and organic solvent used in the reference procedure. - Abstract: A flow-based procedure was developed for the direct spectrophotometric determination of the iodine value (IV) in biodiesel. The procedure was based on the microextraction/reaction of unsaturated compounds with triiodide ions in an aqueous medium by inserting the reagent solution between the aliquots of biodiesel without any pretreatment. The interaction occurred through the biodiesel film formed on the inner walls of the hydrophobic tube used as the reactor and at the aqueous/biodiesel interfaces. The spectrophotometric detection was based on the discoloration of the I 3 − reagent in the aqueous phase by using a glass tube coupled to a fiber-optic spectrophotometer as the detection cell. Reference solutions were prepared by dilution of biodiesel samples with previously determined IV in hexane. The analytical response was linear for IV from 13 to 135 g I 2 /100 g with a detection limit of 5 g I 2 /100 g. A coefficient of variation of 1.7% (n = 10) and a sampling rate of 108 determinations per hour were achieved by consuming 224 μL of the sample and 200 μg of I 2 per determination. The slopes of analytical curves obtained with three different biodiesel samples were in agreement (variations in slopes lower than 3.1%), thus indicating an absence of any matrix effects. Results for biodiesel samples from different sources agreed with the volumetric official procedure at the 95% confidence level. The proposed procedure is therefore a simple, fast, and reliable alternative for estimating the iodine value of biodiesel

  19. Spectrophotometric determination of Sn+2 in lyophilized kit for labeling with 99mTc

    International Nuclear Information System (INIS)

    Araujo, Elaine Bortoleti; Sampel, Carolina Judith; Melo, Ivani Bortoleti; Okamoto, Miriam R.Y; Silva, Constancia P.G

    2004-01-01

    The preparation of 99 mTc labeled radiopharmaceuticals depends on the reduction of the technetium pertechnetate, commonly by stannous chloride (SnCl 2 ). The determination of the Sn +2 contents in the lyophilized preparations represents an important quality control procedure that may be applied to the process and to the final product. The objective os this work is the optimization of an spectrophotometric assay to the determination os Sn +2 contents in a citrate-stannous lyophilized kit for 99 mTc labeling. The spectrophotometric methodology employed is based in the colour development when Sn +2 reacts with sodium molybdate in the presence of potasium thiocyanate in chloridric medium. The colourfull reaction studied showed high stability after 60 minutes of the mixtures preparation. The sequence of reagents introduction in the reaction mixture was determinant to the assay. The molibdenium-stannous-tiocianate sequence produces calibration curves with good correlations (R2 ≥ 0.99). The concentrations of the molibdenium solution was also studied, in order to determine a ideal concentration for the Sn +2 range. The spectrophotometric method studied was usefull to the determination of Sn +2 content in different batches of citrate-stannous preparations. The method was fast and easy and can be applied to different stages of the production process, in order to guarantee the content of Sn +2 in the preparations (Au)

  20. OPTICAL SPECTROSCOPIC OBSERVATIONS OF GAMMA-RAY BLAZAR CANDIDATES. VI. FURTHER OBSERVATIONS FROM TNG, WHT, OAN, SOAR, AND MAGELLAN TELESCOPES

    Energy Technology Data Exchange (ETDEWEB)

    Álvarez Crespo, N.; Massaro, F. [Dipartimento di Fisica, Università degli Studi di Torino, via Pietro Giuria 1, I-10125 Torino (Italy); Milisavljevic, D.; Paggi, A.; Smith, Howard A. [Harvard—Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Landoni, M. [INAF-Osservatorio Astronomico di Brera, Via Emilio Bianchi 46, I-23807 Merate (Italy); Chavushyan, V.; Patiño-Álvarez, V. [Instituto Nacional de Astrofísica, Óptica y Electrónica, Apartado Postal 51-216, 72000 Puebla, México (Mexico); Masetti, N. [INAF—Istituto di Astrofisica Spaziale e Fisica Cosmica di Bologna, via Gobetti 101, I-40129, Bologna (Italy); Jiménez-Bailón, E. [Instituto de Astronomía, Universidad Nacional Autónoma de México, Apdo. Postal 877, Ensenada, 22800 Baja California, México (Mexico); Strader, J.; Chomiuk, L. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Katagiri, H.; Kagaya, M. [College of Science, Ibaraki University, 2-1-1, Bunkyo, Mito 310-8512 (Japan); Cheung, C. C. [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States); D’Abrusco, R. [Department of Physical Sciences, University of Napoli Federico II, via Cinthia 9, I-80126 Napoli (Italy); Ricci, F.; La Franca, F. [Dipartimento di Matematica e Fisica, Università Roma Tre, via della Vasca Navale 84, I-00146, Roma (Italy); and others

    2016-04-15

    Blazars, one of the most extreme classes of active galaxies, constitute so far the largest known population of γ-ray sources, and their number is continuously growing in the Fermi catalogs. However, in the latest release of the Fermi catalog there is still a large fraction of sources that are classified as blazar candidates of uncertain type (BCUs) for which optical spectroscopic observations are necessary to confirm their nature and their associations. In addition, about one-third of the γ-ray point sources listed in the Third Fermi-LAT Source Catalog (3FGL) are still unassociated and lacking an assigned lower-energy counterpart. Since 2012 we have been carrying out an optical spectroscopic campaign to observe blazar candidates to confirm their nature. In this paper, the sixth of the series, we present optical spectroscopic observations for 30 γ-ray blazar candidates from different observing programs we carried out with the Telescopio Nazionale Galileo, William Herschel Telescope, Observatorio Astronómico Nacional, Southern Astrophysical Research Telescope, and Magellan Telescopes. We found that 21 out of 30 sources investigated are BL Lac objects, while the remaining targets are classified as flat-spectrum radio quasars showing the typical broad emission lines of normal quasi-stellar objects. We conclude that our selection of γ-ray blazar candidates based on their multifrequency properties continues to be a successful way to discover potential low-energy counterparts of the Fermi unidentified gamma-ray sources and to confirm the nature of BCUs.

  1. New Spectrophotometric and Conductometric Methods for Macrolide Antibiotics Determination in Pure and Pharmaceutical Dosage Forms Using Rose Bengal

    Directory of Open Access Journals (Sweden)

    Rania A. Sayed

    2013-01-01

    Full Text Available Two Simple, accurate, precise, and rapid spectrophotometric and conductometric methods were developed for the estimation of erythromycin thiocyanate (I, clarithromycin (II, and azithromycin dihydrate (III in both pure and pharmaceutical dosage forms. The spectrophotometric procedure depends on the reaction of rose bengal and copper with the cited drugs to form stable ternary complexes which are extractable with methylene chloride, and the absorbances were measured at 558, 557, and 560 nm for (I, (II, and (III, respectively. The conductometric method depends on the formation of an ion-pair complex between the studied drug and rose bengal. For the spectrophotometric method, Beer's law was obeyed. The correlation coefficient ( for the studied drugs was found to be 0.9999. The molar absorptivity (, Sandell’s sensitivity, limit of detection (LOD, and limit of quantification (LOQ were also calculated. The proposed methods were successfully applied for the determination of certain pharmaceutical dosage forms containing the studied drugs

  2. Reaction of uranium (IV) with xenon difluoride by chemiluminescence, spectrophotometric, and spectrofluorimetric methods

    Energy Technology Data Exchange (ETDEWEB)

    Mamykin, A.V.; Kazakov, V.P.

    1988-07-01

    A study is made of the kinetics of the chemiluminescent reaction of oxidation of uranium (IV) by xenon difluoride in 1M HClO/sub 4/ U/sup 4 +/ + XeF/sub 2/ ..-->.. UO/sub 2//sup 2 +/ = h/eta/. The optical density D and the intensity of the photoluminescence of the solution I/sub PL/ were measured in parallel with recording of the luminescence intensity I/sub CL/. I/sub CL/ attains a maximum value some time after the beginning of the reaction, after which it decays exponentially. On the kinetic curves of the time dependence of D and I/sub PL/ an induction period is observed, the extent of which depends on concentrations of reagents and temperature of the solution. The maximum of I/sub CL/ coincides with the end of the induction period if the measurements are carried out under identical conditions. The rate of the reaction after the induction period is described by a first order equation in U/sup (IV)/. The rate constants of the reaction, obtained by chemiluminescence, spectrophotometric, and spectrofluorimetric methods, have close values 2.0 +- 0.4, 1.8 +- 0.3, and 2.1 +- 0.3 sec/sup /minus/1/ x 10/sup 2/, respectively. On the basis of the results obtained, we conclude that the stages of formation of UO/sub 2//sup 2 +/ and of chemiluminescence coincide, i.e., formation of the excited state (UD/sub 2//sup 2 +/) and of chemiluminescence coincide, i.e., formation of the excited state (UD/sub 2//sup 2 +/)* takes place during the reaction. It is proposed and experimentally verified that the reaction passes through an intermediate stage of formation of uranyl ion UO/sub 2//sup +/.

  3. Observation and measurement of interaction-induced dispersive optical nonlinearities in an ensemble of cold rydberg atoms

    DEFF Research Database (Denmark)

    Parigi, V.; Bimbard, E.; Stanojevic, J.

    2012-01-01

    We observe and measure dispersive optical nonlinearities in an ensemble of cold Rydberg atoms placed inside an optical cavity. The experimental results are in agreement with a simple model where the optical nonlinearities are due to the progressive appearance of a Rydberg blockaded volume within...

  4. High resolution observations using adaptive optics: Achievements and future needs

    Science.gov (United States)

    Sankarasubramanian, K.; Rimmele, T.

    2008-06-01

    Over the last few years, several interesting observations were obtained with the help of solar Adaptive Optics (AO). In this paper, few observations made using the solar AO are enlightened and briefly discussed. A list of disadvantages with the current AO system are presented. With telescopes larger than 1.5 m expected during the next decade, there is a need to develop the existing AO technologies for large aperture telescopes. Some aspects of this development are highlighted. Finally, the recent AO developments in India are also presented.

  5. Spectrophotometric-isotope dilution determination of arsenic in soils and rock

    Science.gov (United States)

    Brown, F.W.; Simon, F.O.; Greenland, L.P.

    1975-01-01

    Arsenic in soil and rock samples may be determined in part-per-million concentrations using a radiochemical-isotope dilution method. Arsenic in the sample plus added As76 tracer is separated as arsine and determined spectrophotometrically as a molybdenum blue complex. The As76 activity in the absorbing solution allows corrections for chemical losses. A lower limit of 1 ppm is determinate in a 0.5-g sample.

  6. Spectrophotometric determination of plutonium with chlorophosphonazo III in n-pentanol

    International Nuclear Information System (INIS)

    Saponara, N.M.; Marsh, S.F.

    1982-03-01

    Microgram amounts of plutonium are measured spectrophotometrically as the plutonium-chlorophosphonazo III complex after extraction into n-pentanol from 1.5 M HCl. The relative standard deviation is 1.5% for the range of 2.5 to 17.5 μg. The tolerance is excellent for many metals and nonmetals present in nuclear fuel-cycle materials. A preceding anion-exchange-column separation increases tolerance for certain metals and nonmetals

  7. Synergistic estimation of surface parameters from jointly using optical and microwave observations in EOLDAS

    Science.gov (United States)

    Timmermans, Joris; Gomez-Dans, Jose; Lewis, Philip; Loew, Alexander; Schlenz, Florian

    2017-04-01

    The large amount of remote sensing data nowadays available provides a huge potential for monitoring crop development, drought conditions and water efficiency. This potential however not been realized yet because algorithms for land surface parameter retrieval mostly use data from only a single sensor. Consequently products that combine different low-level observations from different sensors are hard to find. The lack of synergistic retrieval is caused because it is easier to focus on single sensor types/footprints and temporal observation times, than to find a way to compensate for differences. Different sensor types (microwave/optical) require different radiative transfer (RT) models and also require consistency between the models to have any impact on the retrieval of soil moisture by a microwave instrument. Varying spatial footprints require first proper collocation of the data before one can scale between different resolutions. Considering these problems, merging optical and microwave observations have not been performed yet. The goal of this research was to investigate the potential of integrating optical and microwave RT models within the Earth Observation Land Data Assimilation System (EOLDAS) synergistically to derive biophysical parameters. This system uses a Bayesian data assimilation approach together with observation operators such as the PROSAIL model to estimate land surface parameters. For the purpose of enabling the system to integrate passive microwave radiation (from an ELBARRA II passive microwave radiometer), the Community Microwave Emission Model (CMEM) RT-model, was integrated within the EOLDAS system. In order to quantify the potential, a variety of land surface parameters was chosen to be retrieved from the system, in particular variables that a) impact only optical RT (such as leaf water content and leaf dry matter), b) only impact the microwave RT (such as soil moisture and soil temperature), and c) Leaf Area Index (LAI) that impacts both

  8. Indications of Segmental Flow in Straight Pipes by Flow Injection with Spectrophotometric Detection

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    2000-01-01

    A procedure of spectrophotometric analysis of fluid flow in pipes is described and its performance is tested on three different dye compounds. The procedure follows measurement and mathematical de-convolution of the signal with an exponential function that is associated with molecular diffusion. ...

  9. Spectrophotometric methods for determining noble metals

    International Nuclear Information System (INIS)

    Gur'eva, R.F.; Savvin, S.B.

    2002-01-01

    The main trends of the development of spectrophotometric methods for determining noble metals (NMs) including ruthenium are considered. One of these trends is the synthesis and study of new, highly sensitive and selective organic reagents for determining NMs in solutions and solid phase. Another trend is the search for and developing of new methodological approaches (techniques) and color reactions, including those that involve modified and immobilized reagents. The third trend includes the improvement of equipment and automation. It is shown that the present-day spectrophotometry can provide the determination of NMs in samples with concentrations from several to 10 -4 % (photometry and differential photometry) and down to 10 -7 % (test and sorption-spectroscopic methods based on photometry and diffuse-reflectance spectroscopy, including the use of chromaticity functions) [ru

  10. Analysis of structural and optical properties of annealed fullerene thin films

    Science.gov (United States)

    El-Nahass, M. M.; Ali, H. A. M.; Gadallah, A.-S.; Atta Khedr, M.; Afify, H. A.

    2015-08-01

    Fullerene thin films were thermally deposited onto different substrates. The films annealed at 523 K for 10 h. X-ray diffraction technique was used to examine the structure of the films. The morphology of films was examined by field emission scanning electron microscopy. Fourier transform infrared spectra were recorded in wavenumber range 400-2000 cm-1. The optical characteristics were analyzed using UV- Vis-NIR spectrophotometric measurements in the spectral range 200-2500 nm. The refractive index and extinction coefficient were determined. Some dispersion parameters were calculated such as single oscillator energy, dispersion energy, dielectric constant at high frequency and lattice dielectric constant. As well as, the nonlinear optical susceptibility χ(3) and nonlinear refractive index n2 were determined.

  11. Flame Spectrophotometric Determination of Strontium in Water and Biological Material

    Energy Technology Data Exchange (ETDEWEB)

    Joensson, G

    1964-10-15

    A flame spectrophotometric method has been developed for the determination of strontium in biological material and water samples. Strontium is determined in the presence of calcium at a wavelength of 4607 A. The intensity of the strontium emission from the sample is increased if n-butanol is added to a solution of the sample in water. With a 6 vol% solution of n-butanol in water, an optimum intensity of 3.5 times that obtained with pure water solution is obtained. Anions and alkali metals which might interfere with the flame spectrophotometric determination are separated from the sample by a simple ion exchange operation. The method allows determination of strontium in solutions down to 0.1{mu}g/ml. In this case the standard deviation is 3.1 % and with a strontium concentration of 1 {mu}g/ml the deviation is 0.9 %. This method has been used for the determination of strontium in samples of varying composition such as bone, meat and skin from fishes, samples of human bones, shell-fish, milk, and water, in which case Sr quantities of 5{mu}g were determined with an analytical error of less than 5 % and Sr{sub q}uantities greater than 10 {mu}g with an error of less than 3 %.

  12. Estimation of citicoline sodium in tablets by difference spectrophotometric method

    Directory of Open Access Journals (Sweden)

    Sagar Suman Panda

    2013-01-01

    Full Text Available Aim: The present work deals with development and validation of a novel, precise, and accurate spectrophotometric method for the estimation of citicoline sodium (CTS in tablets. This spectrophotometric method is based on the principle that CTS shows two different forms that differs in the absorption spectra in basic and acidic medium. Materials and Methods: The present work was being carried out on Shimadzu 1800 Double Beam UV-visible spectrophotometer. Difference spectra were generated using 10 mm quartz cells over the range of 200-400 nm. Solvents used were 0.1 M NaOH and 0.1 M HCl. Results: The maxima and minima in the difference spectra of CTS were found to be 239 nm and 283 nm, respectively. Amplitude was calculated from the maxima and minima of spectrum. The drug follows linearity in the range of 1-50 μ/ml (R 2 = 0.999. The average % recovery from the tablet formulation was found to be 98.47%. The method was validated as per International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use: ICH Q2(R1 Validation of Analytical Procedures: Text and Methodology guidelines. Conclusion: This method is simple and inexpensive. Hence it can be applied for determination of the drug in pharmaceutical dosage forms.

  13. Flame Spectrophotometric Determination of Strontium in Water and Biological Material

    International Nuclear Information System (INIS)

    Joensson, G.

    1964-10-01

    A flame spectrophotometric method has been developed for the determination of strontium in biological material and water samples. Strontium is determined in the presence of calcium at a wavelength of 4607 A. The intensity of the strontium emission from the sample is increased if n-butanol is added to a solution of the sample in water. With a 6 vol% solution of n-butanol in water, an optimum intensity of 3.5 times that obtained with pure water solution is obtained. Anions and alkali metals which might interfere with the flame spectrophotometric determination are separated from the sample by a simple ion exchange operation. The method allows determination of strontium in solutions down to 0.1μg/ml. In this case the standard deviation is 3.1 % and with a strontium concentration of 1 μg/ml the deviation is 0.9 %. This method has been used for the determination of strontium in samples of varying composition such as bone, meat and skin from fishes, samples of human bones, shell-fish, milk, and water, in which case Sr quantities of 5μg were determined with an analytical error of less than 5 % and Sr q uantities greater than 10 μg with an error of less than 3 %

  14. Polarographic, spectrophotometric and coulometric studies of MoO=4 in H2SO4

    International Nuclear Information System (INIS)

    Tokoro, R.; Bertotti, M.

    1990-01-01

    This study characterizes the polarographic process of Mo O sup(=) sub(4) in H sub(2)SO sub(4) medium, determining which species is responsible by catalytic cycle. Spectrophotometric and coulometric studies are also described. (author)

  15. Observations and modeling of fog by cloud radar and optical sensors

    NARCIS (Netherlands)

    Li, Y.; Hoogeboom, P.; Russchenberg, H.

    2014-01-01

    Fog is a significant factor affecting the public traffic because visibility is reduced to a large extent. Therefore the determination of optical visibility in fog from radar instruments has received much interest. To observe fog with radar, high frequency bands (millimeter waves) have the best

  16. Rapid visual and spectrophotometric nitrite detection by cyclometalated ruthenium complex.

    Science.gov (United States)

    Lo, Hoi-Shing; Lo, Ka-Wai; Yeung, Chi-Fung; Wong, Chun-Yuen

    2017-10-16

    Quantitative determination of nitrite ion (NO 2 - ) is of great importance in environmental and clinical investigations. A rapid visual and spectrophotometric assay for NO 2 - detection was developed based on a newly designed ruthenium complex, [Ru(npy)([9]aneS3)(CO)](ClO 4 ) (denoted as RuNPY; npy = 2-(1-naphthyl)pyridine, [9]aneS3 = 1,4,7-trithiacyclononane). This complex traps NO + produced in acidified NO 2 - solution, and yields observable color change within 1 min at room temperature. The assay features excellent dynamic range (1-840 μmol L -1 ) and high selectivity, and its limit of detection (0.39 μmol L -1 ) is also well below the guideline values for drinking water recommended by WHO and U.S. EPA. Practical use of this assay in tap water and human urine was successfully demonstrated. Overall, the rapidity and selectivity of this assay overcome the problems suffered by the commonly used modified Griess assays for nitrite determination. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Observation of an optical vortex beam from a helical undulator in the XUV region.

    Science.gov (United States)

    Kaneyasu, Tatsuo; Hikosaka, Yasumasa; Fujimoto, Masaki; Iwayama, Hiroshi; Hosaka, Masahito; Shigemasa, Eiji; Katoh, Masahiro

    2017-09-01

    The observation of an optical vortex beam at 60 nm wavelength, produced as the second-harmonic radiation from a helical undulator, is reported. The helical wavefront of the optical vortex beam was verified by measuring the interference pattern between the vortex beam from a helical undulator and a normal beam from another undulator. Although the interference patterns were slightly blurred owing to the relatively large electron beam emittance, it was possible to observe the interference features thanks to the helical wavefront of the vortex beam. The experimental results were well reproduced by simulation.

  18. Observation of an optical event horizon in a silicon-on-insulator photonic wire waveguide.

    Science.gov (United States)

    Ciret, Charles; Leo, François; Kuyken, Bart; Roelkens, Gunther; Gorza, Simon-Pierre

    2016-01-11

    We report on the first experimental observation of an optical analogue of an event horizon in integrated nanophotonic waveguides, through the reflection of a continuous wave on an intense pulse. The experiment is performed in a dispersion-engineered silicon-on-insulator waveguide. In this medium, solitons do not suffer from Raman induced self-frequency shift as in silica fibers, a feature that is interesting for potential applications of optical event horizons. As shown by simulations, this also allows the observation of multiple reflections at the same time on fundamental solitons ejected by soliton fission.

  19. SPECTROPHOTOMETRIC ASSESSMENT OF FERRIC REDUCING POWER OF THE INSTANT COFFEE

    OpenAIRE

    Tsiupko, T. G.; Tishchenko, E. A.; Voronova, O. B.

    2016-01-01

    The methods of antioxidant activity determination of foodstuffs using different indicator systems were discussed. The investigation of ferric reducing power (FRP) of coffee and its individual phenolic components such as chlorogenic (CGA), caffeic (СА), ferulic (FA), gallic (GA), vanillic (VA), protocatechuic (PCA) and uric (UA) acids as well as quercetin (Qu) and catechol (C) using the spectrophotometric method with Fe(III) - o-Phen indicator system was carried out. It was shown that the sens...

  20. A loss-based, magnetic field sensor implemented in a ferrofluid infiltrated microstructured polymer optical fiber

    International Nuclear Information System (INIS)

    Candiani, A.; Argyros, A.; Leon-Saval, S. G.; Lwin, R.; Selleri, S.; Pissadakis, S.

    2014-01-01

    We report an in-fiber magnetic field sensor based on magneto-driven optical loss effects, while being implemented in a ferrofluid infiltrated microstructured polymer optical fiber. We demonstrate that magnetic field flux changes up to 2000 gauss can be detected when the magnetic field is applied perpendicular to the fiber axis. In addition, the sensor exhibits high polarization sensitivity for the interrogated wavelengths, providing the possibility of both field flux and direction measurements. The underlying physical and guidance mechanisms of this sensing transduction are further investigated using spectrophotometric, light scattering measurements, and numerical simulations, suggesting photonic Hall effect as the dominant physical, transducing mechanism

  1. Spectrophotometric Rapid-Response Classification of Near-Earth Objects

    Science.gov (United States)

    Mommert, Michael; Trilling, David; Butler, Nat; Axelrod, Tim; Moskovitz, Nick; Jedicke, Robert; Pichardo, Barbara; Reyes-Ruiz, Mauricio

    2015-08-01

    Small NEOs are, as a whole, poorly characterized, and we know nothing about the physical properties of the majority of all NEOs. The rate of NEO discoveries is increasing each year, and projects to determine the physical properties of NEOs are lagging behind. NEOs are faint, and generally even fainter by the time that follow-up characterizations can be made days or weeks after their discovery. There is a need for a high-throughput, high-efficiency physical characterization strategy in which hundreds of faint NEOs can be characterized each year. Broadband photometry in the near-infrared is sufficiently diagnostic to assign taxonomic types, and hence constrain both the individual and ensemble properties of NEOs.We present results from our rapid response near-infrared spectrophotometric characterization program of NEOs. We are using UKIRT (on Mauna Kea) and the RATIR instrument on the 1.5m telescope at the San Pedro Martir Observatory (Mexico) to allow us to make observations most nights of the year in robotic/queue mode. We derive taxonomic classifications for our targets using machine-learning techniques that are trained on a large sample of measured asteroid spectra. For each target we assign a probability for it to belong to a number of different taxa. Target selection, observation, data reduction, and analysis are highly automated, requiring only a minimum of user interaction, making this technique powerful and fast. Our targets are NEOs that are generally too faint for other characterization techniques, or would require many hours of large telescope time.

  2. Analysis of Protein by Spectrophotometric and Computer Colour Based Intensity Method from Stem of Pea (Pisum sativum at Different Stages

    Directory of Open Access Journals (Sweden)

    Afsheen Mushtaque Shah

    2010-12-01

    Full Text Available In this study proteins were analyzed from pea plants at three different growth stages of stem by spectrophotometric i.e Lowry and Bradford quantitative methods and computer colour intensity based method. Though Spectrophotometric methods are regarded as classical methods, we report an alternate computer based method which gave comparable results. Computer software was developed the for protein analysis which is easier, time and money saving method as compared to the classical methods.

  3. Spectrophotometric study of holmium complexation in KOH solutions at 25 Deg C

    International Nuclear Information System (INIS)

    Stepanchikova, S.A.; Bitejkina, R.P.

    2006-01-01

    Complexation of Ho 3+ in solutions of HoCl 3 and KOH at 25 Deg C is studied by indicator spectrophotometric method. Within the range of pH 9.25-10.10 and μ≤4 x 10 -4 stability constants of Ho 3+ hydroxocomplexes are measured and are extrapolated on zero ion strength [ru

  4. Determination of cyanide by an indirect spectrophotometric method using 5-Br-PADAP.

    Science.gov (United States)

    Fu-Sheng, W; Yu-Qin, L; Fang, Y; Nai-Kui, S

    1981-09-01

    Complexation of Ni(2+) with cyanide inhibits its colour reaction with 5-Br-PADAP and this reaction is used in the spectrophotometric determination of cyanide at the ug level. Cyanide in industrial waste waters is determined after an initial transfer as hydrogen cyanide from the sample into sodium hydroxide solution with a stream of air.

  5. Coronal structures and particle acceleration studies from radioelectric and optical observations

    International Nuclear Information System (INIS)

    Axisa, Francois.

    1974-01-01

    The problem of acceleration outside of and during eruptions is studied from the association of type III radioelectric jumps with the chromosphere activity observed in absorption and emission of the Hα line. In addition the mean corona structure is investigated from observation of the slowly variable metric wave component in connection with coronal filaments and jets, and by type III emission in relation to the eruptive sites of complex active regions. Most of the experimental material comes from observations made with the Nancay East-West radioheliograph, which works on 169 MHz and optical observations carried out at the Meudon Observatory on the chromosphere and on photosphere magnetic fields [fr

  6. Quasi-simultaneous ultraviolet, optical, and infrared observations of the BL Lacertae object PKS 0048-09

    International Nuclear Information System (INIS)

    Falomo, R.; Bouchet, P.; Maraschi, L.; Treves, A.; Tanzi, E.G.

    1988-01-01

    This paper reports on quasi-simultaneous UV, optical, and IR observations of the BL Lac object PKS 0048-09, carried out on January 7-9, 1987, when the object was in a moderately high optical state. The data were used to derive a detailed energy distribution from about 10 to the 14th to about 2.5 x 10 to the 15th Hz. A comparison of observations obtained on January 7-9, 1987, with observations on September 12, 1986, pertaining to a lower state of the source, indicates spectral hardening with increasing intensity on time scales of months. 26 references

  7. Quasi-simultaneous ultraviolet, optical, and infrared observations of the BL Lacertae object PKS 0048-09

    Energy Technology Data Exchange (ETDEWEB)

    Falomo, R.; Bouchet, P.; Maraschi, L.; Treves, A.; Tanzi, E.G.

    1988-12-01

    This paper reports on quasi-simultaneous UV, optical, and IR observations of the BL Lac object PKS 0048-09, carried out on January 7-9, 1987, when the object was in a moderately high optical state. The data were used to derive a detailed energy distribution from about 10 to the 14th to about 2.5 x 10 to the 15th Hz. A comparison of observations obtained on January 7-9, 1987, with observations on September 12, 1986, pertaining to a lower state of the source, indicates spectral hardening with increasing intensity on time scales of months. 26 references.

  8. Highly Selective and Sensitized Spectrophotometric Determination of Iron (3) Following Potentiometric Study

    International Nuclear Information System (INIS)

    Shokrollahi, A.; Ghaedi, M.; Rajabi, H.R.

    2007-01-01

    A simple, selective and sensitized spectrophotometric method for determination of trace amounts of Fe 3+ ion in tap and waste water solutions has been described. The spectrophotometric determination of Fe 3+ ion using Ferron in the presence of N,N-Dodecy trimethylammonium bromide (DTAB) has been carried out. The Beer's law is obeyed over the concentration range of 0.05-2.6 μg mL -1 of Fe 3+ ion with the relative standard deviation (RSD %) 3 L mol -1 cm -1 . Potentiometric pH titration has been used for prediction of protonation constants of ferron, and evaluating its stoichiometry and respective stability constant with Fe 3+ ion. As it is obvious the most likely species of ferron alone and its complexes are LH (log=7.64), LH 2 (logK=10.52), LH 3 (logK=11.74) and ML 2 (logβ= 23.68), ML 3 (logβ23.68), ML 3 H (logβ= 23.68), ML 3 H 2 (logβ= 23.68) and ML(OH) 2 (logβ=23.68) respectively

  9. Spectrophotometric determination of chlorthalidone in pharmaceutical formulations using different order derivative methods

    Directory of Open Access Journals (Sweden)

    Narmeen S. Abdullah

    2017-05-01

    Full Text Available Simple, repaid and accurate zero-, first- and second-order derivative spectrophotometric methods have been developed for determination of chlorthalidone (CLT in commercially available tablets. Normal spectrophotometric scan (zero order shows maximum absorbance at 276 nm in methanol solution and a good linearity in the range of 10.0–75.0 μg/mL. Linear relations using first (D1 and second (D2 order derivative methods were obtained at 278 and 288 nm for D1 and 286 and 292 nm for D2.The calibration curves were constructed in the range of 1.0–25.0 μg/mL for D1 (R = 0.998 and D2 (R = 0.999. Different analytical validations were determined (accuracy, precision, specificity, recovery, stability and robustness to demonstrate its suitability for routine quality control labs. All the developed methods were successfully applied to a tablet formulation and the results were compared statistically with each other and with those obtained by the HPLC reference method.

  10. Structural and optical properties of furfurylidenemalononitrile thin films

    Science.gov (United States)

    Ali, H. A. M.

    2013-03-01

    Thin films of furfurylidenemalononitrile (FMN) were deposited on different substrates at room temperature by thermal evaporation technique under a high vacuum. The structure of the powder was confirmed by Fourier transformation infrared (FTIR) technique. The unit cell dimensions were determined from X-ray diffraction (XRD) studies. The optical properties were investigated using spectrophotometric measurements of the transmittance and reflectance at normal incidence of light in the wavelength range from 200 to 2500 nm. The refractive index (n), the absorption index (k) and the absorption coefficient (α) were calculated. The analysis of the spectral behavior of the absorption coefficient in the absorption region revealed an indirect allowed transition. The refractive index dispersion was analyzed using the single oscillator model. Some dispersion parameters were estimated. Complex dielectric function and optical conductivity were determined. The influence of the irradiation with high-energy X-rays (6 MeV) on the studied properties was also investigated.

  11. Structural and Optical Properties of Nanocrystalline 3,4,9,10-Perylene-Tetracarboxylic-Diimide Thin Film

    Directory of Open Access Journals (Sweden)

    M. M. El-Nahhas

    2012-01-01

    Full Text Available Thin films of nanocrystalline 3,4,9,10-perylene-tetracarboxylic-diimide (PTCDI were prepared on quartz substrates by thermal evaporation technique. The structural properties were identified by transmission electron microscopy (TEM and the X-ray diffraction (XRD. The optical properties for the films were investigated using spectrophotometric measurements of the transmittance and reflectance at normal incidence of light in the wavelength range from 200 to 2500 nm. The optical constants (refractive index n and absorption index k were calculated and found to be independent on the film thickness in the measured film thickness range 117–163 nm. The dispersion energy (Ed, the oscillator energy (Eo, and the high-frequency dielectric constant ε∞ were obtained. The energy band model was applied, and the types of the optical transitions responsible for optical absorption were found to be indirect allowed transition. The onset and optical energy gaps were calculated, and the obtained results were also discussed.

  12. OPTICAL SPECTROSCOPY AND NEBULAR OXYGEN ABUNDANCES OF THE SPITZER/SINGS GALAXIES

    International Nuclear Information System (INIS)

    Moustakas, John; Kennicutt, Robert C. Jr.; Tremonti, Christy A.; Dale, Daniel A.; Smith, John-David T.; Calzetti, Daniela

    2010-01-01

    We present intermediate-resolution optical spectrophotometry of 65 galaxies obtained in support of the Spitzer Infrared Nearby Galaxies Survey (SINGS). For each galaxy we obtain a nuclear, circumnuclear, and semi-integrated optical spectrum designed to coincide spatially with mid- and far-infrared spectroscopy from the Spitzer Space Telescope. We make the reduced, spectrophotometrically calibrated one-dimensional spectra, as well as measurements of the fluxes and equivalent widths of the strong nebular emission lines, publicly available. We use optical emission-line ratios measured on all three spatial scales to classify the sample into star-forming, active galactic nuclei (AGNs), and galaxies with a mixture of star formation and nuclear activity. We find that the relative fraction of the sample classified as star forming versus AGN is a strong function of the integrated light enclosed by the spectroscopic aperture. We supplement our observations with a large database of nebular emission-line measurements of individual H II regions in the SINGS galaxies culled from the literature. We use these ancillary data to conduct a detailed analysis of the radial abundance gradients and average H II-region abundances of a large fraction of the sample. We combine these results with our new integrated spectra to estimate the central and characteristic (globally averaged) gas-phase oxygen abundances of all 75 SINGS galaxies. We conclude with an in-depth discussion of the absolute uncertainty in the nebular oxygen abundance scale.

  13. Spectrophotometric and computerized evaluation of tooth bleaching employing 10 different home-bleaching procedures: In-vitro study

    Science.gov (United States)

    Peskersoy, Cem; Tetik, Ayhan; Ozturk, Veli Ozgen; Gokay, Necmi

    2014-01-01

    Objective: The aim of this in-vitro study was to evaluate the efficacy of bleaching products, determine the applicability and validation of the measurement methods. Materials and Methods: Freshly extracted 110 human incisor teeth were stained with whole blood and hemolysate solution prior to the application of 10 different home-bleaching products. Spectrophotometric measurements of the tooth shades were performed for each specimen before and after bleaching at the 1st, 3rd, 7th, and 14 days. Differences in lightness (Δl), chroma (Δc), hue (Δh) values and shade changes were measured to evaluate process. Computerized digital imaging analyses to determine the color changes were performed with Photoshop CS4 software (Adobe, San Jose, CA, USA). Statistical analyses were performed with analysis of variance, Scheffe and Tukey tests. Results: In all of the test groups regardless of the material used, a significant increase in lightness and hue, and decrease of chroma were observed, as compared to the control group. After recommended bleaching applications, Δl and Δh values respectively increased in group Zaris White and Brite (ZWB) and group Pola Night and Δc values showed significant decrease in groups ZWB and Rembrandt REM3 (P bleaching systems showed slower but almost permanent bleaching effect likewise office-based methods. Both software and spectrophotometric analyses have advantages such as evaluating the results objectively and numerically, also treatment outcomes could be preserved. PMID:25512738

  14. Spectrophotometric determination of fluorides in water with Hach equipment

    International Nuclear Information System (INIS)

    Acosta L, E.

    1994-11-01

    The spectrophotometric method for the determination of the fluoride ion in water, demineralized water, raw waters, laundry waters and waters treated with ion exchange resins , using the technique and the SPADNS coloring indicated in the operation manual of the Hach equipment is described. This method covers the determination of the fluoride ion in the range from 0 to 2 mg/l on 25 ml. of radioactive base sample. These limits can be variable if the size of the used aliquot one is changed for the final determination of the fluoride ion. (Author)

  15. Development and application of spectrophotometric method for the determination of cefaclor in pharmaceutical formulations

    Directory of Open Access Journals (Sweden)

    Asad Raza

    2009-01-01

    Full Text Available A simple, fast and sensitive spectrophotometric method for the determination of cefaclor in pharmaceutical raw and dosage forms based on reaction with ninhydrin is developed, optimized and validated. The purple color (Ruhemenn's purple that resulted from the reaction was stabilized and measured at 560 nm. Beer's law is obeyed in the concentration range of 4-80 µg mL-1 with molar absorptivity of 1.42 × 10(5 L mole-1 cm-1. All variables including the reagent concentration, heating time, reaction temperature, color stability period, and cefaclor/ninhydrin ratio were studied in order to optimize the reaction conditions. No interference was observed from common pharmaceutical adjuvant. The developed method is easy to use, accurate and highly cost-effective for routine studies relative to HPLC and other techniques.

  16. High resolution earth observation from geostationary orbit by optical aperture synthesys

    Science.gov (United States)

    Mesrine, M.; Thomas, E.; Garin, S.; Blanc, P.; Alis, C.; Cassaing, F.; Laubier, D.

    2017-11-01

    In this paper, we describe Optical Aperture Synthesis (OAS) imaging instrument concepts studied by Alcatel Alenia Space under a CNES R&T contract in term of technical feasibility. First, the methodology to select the aperture configuration is proposed, based on the definition and quantification of image quality criteria adapted to an OAS instrument for direct imaging of extended objects. The following section presents, for each interferometer type (Michelson and Fizeau), the corresponding optical configurations compatible with a large field of view from GEO orbit. These optical concepts take into account the constraints imposed by the foreseen resolution and the implementation of the co-phasing functions. The fourth section is dedicated to the analysis of the co-phasing methodologies, from the configuration deployment to the fine stabilization during observation. Finally, we present a trade-off analysis allowing to select the concept wrt mission specification and constraints related to instrument accommodation under launcher shroud and in-orbit deployment.

  17. Simultaneous determination of the brand new two-drug combination for the treatment of hepatitis C: Sofosbuvir/ledipasvir using smart spectrophotometric methods manipulating ratio spectra

    Science.gov (United States)

    Eissa, Maya S.

    2017-08-01

    In this work, various sensitive and selective spectrophotometric methods were first introduced for the simultaneous determination of sofosbuvir and ledipasvir in their binary mixture without preliminary separation. Ledipasvir was determined simply by zero-order spectrophotometric method at its λmax = 333.0 nm in a linear range of 2.5-30.0 μg/ml without any interference of sofosbuvir even in low or high concentrations and with mean percentage recovery of 100.05 ± 0.632. Sofosbuvir can be quantitatively estimated by one of the following smart spectrophotometric methods based on ratio spectra developed for the resolution of the overlapped spectra of their binary mixture; ratio difference spectrophotometric method (RD) by computing the difference between the amplitudes of sofosbuvir ratio spectra at 228 nm and 270 nm, first derivative (DD1) of ratio spectra by measuring the sum of amplitude of trough and peak at 265 nm and 277 nm, respectively, ratio subtraction (RS) spectrophotometric method in which sofosbuvir can be successfully determined at its λmax = 261.0 nm and mean centering (MC) of ratio spectra by measuring the mean centering values at 270 nm. All of the above mentioned spectrophotometric methods can estimate sofosbuvir in a linear range of 7.5-90.0 μg/ml with mean percentage recoveries of 100.57 ± 0.810, 99.92 ± 0.759, 99.51 ± 0.475 and 100.75 ± 0.672, respectively. These methods were successfully applied to the analysis of their combined dosage form and bulk powder. The adopted methods were also validated as per ICH guidelines and statistically compared to an in-house HPLC method.

  18. The spectrophotometric determination of boron in tourmalines

    Directory of Open Access Journals (Sweden)

    LJILJANA JAKSIC

    2005-02-01

    Full Text Available A procedure for the spectrophotometric determination of macro amounts of boron in tourmaline with azomethine H is described. The used tourmaline concentrate was obtained by magnetic separation and heavy-liquids purification of the schorl zone of pegmatite or granite aplite. The samples of tourmaline were decomposed by fusion with anhydrous sodium carbonate and taken up in dilute hydrochloric acid. The interfering effects of iron and aluminium were eliminated by masking with an EDTA – NTA solution. After pH adjustment, the boron was reacted with azomethine H and the absorbance of the obtained coloured complex was measured at 415 nm. The results are compared with those obtained by other procedures. The relative error of the determination was less than 3 %.

  19. Spectrophotometric determination of procainamide hydrochloride using sodium periodate

    Directory of Open Access Journals (Sweden)

    S. Al-Tamrah

    2015-09-01

    Full Text Available A simple spectrophotometric method has been described for the determination of procainamide hydrochloride. The method is based on the oxidation of procainamide hydrochloride by sodium periodate in the presence of sulfuric acid and measurement of the absorbance of the violet color formed at 531 nm. Parameters affecting the reaction were studied and conditions were optimized. Linear calibration graph was obtained from 50 to 700 μg ml−1 of procainamide hydrochloride and the limit of detection was 25 μg ml−1. The method was successfully applied for the determination of procainamide hydrochloride in pharmaceutical preparation.

  20. Correlation between the structural and optical properties of ion-assisted hafnia thin films

    Science.gov (United States)

    Scaglione, Salvatore; Sarto, Francesca; Alvisi, Marco; Rizzo, Antonella; Perrone, Maria R.; Protopapa, Maria L.

    2000-03-01

    The ion beam assistance during the film growth is one of the most useful method to obtain dense film along with improved optical and structural properties. Afnia material is widely used in optical coating operating in the UV region of the spectrum and its optical properties depend on the production method and the physical parameters of the species involved in the deposition process. In this work afnia thin films were evaporated by an e-gun and assisted during the growth process. The deposition parameters, ion beam energy, density of ions impinging on the growing film and the number of arrival atoms from the crucible, have been related to the optical and structural properties of the film itself. The absorption coefficient and the refractive index were measured by spectrophotometric technique while the microstructure has been studied by means of x-ray diffraction. A strictly correlation between the grain size, the optical properties and the laser damage threshold measurements at 248 nm was found for the samples deposited at different deposition parameters.

  1. Bio-optical water quality dynamics observed from MERIS in Pensacola Bay, Florida

    Science.gov (United States)

    Observed bio-optical water quality data collected from 2009 to 2011 in Pensacola Bay, Florida were used to develop empirical remote sensing retrieval algorithms for chlorophyll a (Chla), colored dissolved organic matter (CDOM), and suspended particulate matter (SPM). Time-series ...

  2. Spectrophotometric determination of phosphorus in iron alloys employing a flow injection system

    Directory of Open Access Journals (Sweden)

    Gervasio Ana P. G.

    2001-01-01

    Full Text Available A flow-injection procedure for spectrophotometric determination of phosphorus in electrolytic iron and iron alloys is proposed. The method is based on the ammonium molybdate reaction followed by stannous chloride reduction in acidic medium. In order to circumvent the severe interference caused by the major constituents such as Fe(III and Cr(III, a mini-column packed with AG50W-X8 resin was coupled to the manifold. A sample throughput of 40 determinations per hour, a dynamical range from P 0.25 to 6.00 mg L-1, a reagent consumption of 25 mg ammonium molybdate and 2 mg stannous chloride per determination, and a relative standard deviation < 1% (n = 10 for a typical sample with 2.20 mg L-1 P were achieved. Three different types of samples were used to evaluate system performance. Accuracy was assessed by comparing the results with certified values and no significant difference at 95 % confidence level was observed.

  3. Deep Optical Observations of Unusual Neutron Star Calvera with the GTC

    Science.gov (United States)

    Shibanov, Yury; Danilenko, Andrey; Zharikov, Sergey; Shternin, Peter; Zyuzin, Dima

    2016-11-01

    Calvera is an unusual, isolated neutron star with a pure thermal X-ray spectrum typical of central compact objects in supernova remnants. On the other hand, its rotation period and spin-down rate are typical of ordinary rotation-powered pulsars. It was discovered and studied through X-rays, and has not yet been detected in other spectral domains. We present deep optical imaging of the Calvera field, obtained with the Gran Telescopio Canarias, in the g\\prime and I\\prime bands. Within the vicinity of ≈ 1\\prime\\prime of Calvera, we detected two point-like objects that were invisible at previous shallow observations. However, accurate astrometry showed that neither of them can be identified with the pulsar. We put new upper limits of g\\prime \\gt 27.87 and I\\prime \\gt 26.84 on its optical brightness. We also reanalyzed all available archival X-ray data on Calvera. Comparison of the Calvera thermal emission parameters and upper limits on optical and non-thermal X-ray emission with respective data on rotation-powered pulsars shows that Calvera might belong to the class of ordinary middle-aged pulsars, if we assume that its distance is in the range of 1.5-5 kpc. Based on observations made with the Gran Telescopio Canarias (GTC), installed in the Spanish Observatorio del Roque de los Muchachos of the Instituto de Astrofisica de Canarias, on the island of La Palma, program GTC1-14AMEX.

  4. Optical and infrared observations of SN 1987A from Cerro Tololo Inter-American Observatory

    International Nuclear Information System (INIS)

    Phillips, M.M.

    1988-01-01

    Results from optical and infrared observations of SN 1987A obtained at Cerro Tololo Inter-American Observatory over the first seven months since core collapse are reviewed. Around 130 days after outburst, the bolometric light curve began to smoothly decline at a rate of ∼ 0.01 mag day-1, providing dramatic confirmation of the prediction that radioactivity had powered the optical display after the first month./ the peculiar color changes are kinks observed beginning on the 25th day probably signaled the initial release of trapped energy from mass 56 material. The bolometric luminosity of SN 1987A was unusually low at first, but reached a value more typical of other type II supernovae by the time that the final exponential decline had begun. Over much of the period covered by these observations, the optical and infrared spectra were characterized by strong absorption lines of Ba II and Sr II. Comparison with the spectra of other type II supernovae at similar stages of evolution supports the suggestion that s-processed elements were enriched in the hydrogen envelope of the progenitor, Sanduleak - 69 degrees 202

  5. High precision spectrophotometric analysis of thorium

    International Nuclear Information System (INIS)

    Palmieri, H.E.L.

    1984-01-01

    An accurate and precise determination of thorium is proposed. Precision of about 0,1% is required for the determination of macroquantities of thorium when processed. After an extensive literature search concerning this subject, spectrophotometric titration has been chosen, using dissodium ethylenediaminetetraacetate (EDTA) solution and alizarin-S as indicator. In order to obtain such a precision, an amount of 0,025 M EDTA solution precisely measured has been added and the titration was completed with less than 5 ml of 0,0025 M EDTA solution. It is usual to locate the end-point graphically, by plotting added titrant versus absorbance. The non-linear minimum square fit, using the Fletcher e Powell's minimization process and a computer programme. Besides the equivalence point, other parameters of titration were determined: the indicator concentration, the absorbance of the metal-indicator complex, and the stability constants of the metal-indicator and the metal-EDTA complexes. (Author) [pt

  6. Stopped-flow injection spectrophotometric method for determination of chlorate in soil

    Directory of Open Access Journals (Sweden)

    Jaroon Jakmunee

    2008-06-01

    Full Text Available A stopped-flow injection (FI spectrophotometric procedure based on iodometric reaction for the determination of chlorate has been developed. Standard/sample was injected into a stream of potassium iodide solution and then merged with a stream of hydrochloric acid solution to produce triiodide. By stopping the flow while the sample zone is being in a mixing coil, a slow reaction of chlorate with iodide in acidic medium was promoted to proceed with minimal dispersion of the triiodide product zone. When the flow started again, a concentrated product zone was pushed into a flow cell and a signal profile due to light absorption of the product was recorded. Employing a lab-built semi-automatic stopped-FI analyser, the analysis can be performed with higher degree of automation and low chemical consumption. Linear calibration graph in the range of 5-50 mg ClO3- L-1 was obtained, with detection limit of 1.4 mg ClO3- L-1. Relative standard deviation of 2.2% (30 mg ClO3- L-1, n=10 and sample throughput of about 20 h-1 were achieved. The system was applied to soil samples and validated by batch spectrophotometric and standard titrimetric methods.

  7. Spectrophotometric and spectrofluorimetric determination of some drugs containing secondary amino group in bulk drug and dosage forms via derivatization with 7-Chloro-4-Nitrobenzofurazon

    Directory of Open Access Journals (Sweden)

    Armaan Önal

    2011-01-01

    Full Text Available Sensitive and selective spectrophotometric and spectrofluorimetric methods have been developed for determination of some drugs such as Pramipexole, Nebivolol, Carvedilol, and Eletriptan, which commonly contain secondary amino group. The subject methods were developed via derivatization of the secondary amino groups with 7-Chloro-4-Nitrobenzofurazon in borate buffer where a yellow colored reaction product was obtained and measured spectrophotometrically or spectrofluorimetrically. Concentration ranges were found as 2.0 to 250 μg mL-1 and 0.1 to 3.0 μg mL-1, for spectrophotometric and spectrofluorimetric study, respectively. The described methods can be easily applied by the quality control laboratories in routine analyses of these drugs in pharmaceutical preparations.

  8. TOWARD A NETWORK OF FAINT DA WHITE DWARFS AS HIGH-PRECISION SPECTROPHOTOMETRIC STANDARDS

    Energy Technology Data Exchange (ETDEWEB)

    Narayan, G.; Matheson, T.; Saha, A.; Claver, J. [National Optical Astronomy Observatory, 950 North Cherry Avenue, Tucson, AZ 85719 (United States); Axelrod, T.; Olszewski, E. [University of Arizona, Steward Observatory, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Holberg, J. B. [University of Arizona, Lunar and Planetary Laboratory, 1629 East University Boulevard, Tucson, AZ 85721 (United States); Stubbs, C. W. [Department of Physics, Harvard University, 17 Oxford Street, Cambridge, MA 02138 (United States); Bohlin, R. C.; Deustua, S.; Rest, A., E-mail: gnarayan@noao.edu [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States)

    2016-05-10

    We present the initial results from a program aimed at establishing a network of hot DA white dwarfs to serve as spectrophotometric standards for present and future wide-field surveys. These stars span the equatorial zone and are faint enough to be conveniently observed throughout the year with large-aperture telescopes. The spectra of these white dwarfs are analyzed in order to generate a non-local-thermodynamic-equilibrium model atmosphere normalized to Hubble Space Telescope colors, including adjustments for wavelength-dependent interstellar extinction. Once established, this standard star network will serve ground-based observatories in both hemispheres as well as space-based instrumentation from the UV to the near IR. We demonstrate the effectiveness of this concept and show how two different approaches to the problem using somewhat different assumptions produce equivalent results. We discuss the lessons learned and the resulting corrective actions applied to our program.

  9. The analysis of impurities in the diuranate-determination of phosphate by phosphomolybdate blue spectrophotometric method

    International Nuclear Information System (INIS)

    Sun Haobo

    2014-01-01

    Phosphomolybdenum blue spectrophotometric method was used for determination of phosphate in the diuranate. Diuranate was dissolved in nitric acid solution, in which formed a soluble heteropolyacid complex (namely phosphomolybdenum yellow) due to interaction of phosphate and ammonium molybdate. Then phosphomolybdenum yellow was reduced to phosphomolybdenum blue with Bismuth nitrate as catalyst. Colour intensity at 700 nm is in proportion to the content of phosphate determined by spectrophotometric method. This experiment presents good linearity at the range of 30 μg to 245 μg phosphate, and the relative standard deviation of the experimental result is 2.4%, and the recovery rate is from 95% to 105%. The determination result of phosphate content will not be effected under conditions of 4 mg of SiO 2 , 6 mg of Fe, 400 mg of Cl - and 4.5 mg of Ge in the solution. (author)

  10. XBAER-derived aerosol optical thickness from OLCI/Sentinel-3 observation

    Science.gov (United States)

    Mei, Linlu; Rozanov, Vladimir; Vountas, Marco; Burrows, John P.; Richter, Andreas

    2018-02-01

    A cloud identification algorithm used for cloud masking, which is based on the spatial variability of reflectances at the top of the atmosphere in visible wavelengths, has been developed for the retrieval of aerosol properties by MODIS. It is shown that the spatial pattern of cloud reflectance, as observed from space, is very different from that of aerosols. Clouds show a high spatial variability in the scale of a hundred metres to a few kilometres, whereas aerosols in general are homogeneous. The concept of spatial variability of reflectances at the top of the atmosphere is mainly applicable over the ocean, where the surface background is sufficiently homogeneous for the separation between aerosols and clouds. Aerosol retrievals require a sufficiently accurate cloud identification to be able to mask these ground scenes. However, a conservative mask will exclude strong aerosol episodes and a less conservative mask could introduce cloud contamination that biases the retrieved aerosol optical properties (e.g. aerosol optical depth and effective radii). A detailed study on the effect of cloud contamination on aerosol retrievals has been performed and parameters are established determining the threshold value for the MODIS aerosol cloud mask (3×3-STD) over the ocean. The 3×3-STD algorithm discussed in this paper is the operational cloud mask used for MODIS aerosol retrievals over the ocean.A prolonged pollution haze event occurred in the northeast part of China during the period 16-21 December 2016. To assess the impact of such events, the amounts and distribution of aerosol particles, formed in such events, need to be quantified. The newly launched Ocean Land Colour Instrument (OLCI) onboard Sentinel-3 is the successor of the MEdium Resolution Imaging Spectrometer (MERIS). It provides measurements of the radiance and reflectance at the top of the atmosphere, which can be used to retrieve the aerosol optical thickness (AOT) from synoptic to global scales. In this

  11. How Much Cranberry Juice Is in Cranberry-Apple Juice? A General Chemistry Spectrophotometric Experiment

    Science.gov (United States)

    Edionwe, Etinosa; Villarreal, John R.; Smith, K. Christopher

    2011-01-01

    A laboratory experiment that spectrophotometrically determines the percent of cranberry juice in cranberry-apple juice is described. The experiment involves recording an absorption spectrum of cranberry juice to determine the wavelength of maximum absorption, generating a calibration curve, and measuring the absorbance of cranberry-apple juice.…

  12. Spectrophotometric determination of the sulfhydryl containing drug mesna

    Directory of Open Access Journals (Sweden)

    Rim S. Haggag

    2016-06-01

    Full Text Available Four simple and sensitive spectrophotometric methods were developed for the determination of the sulfhydryl containing drug mesna (MSN. Methods I and II rely on nucleophilic aromatic substitution reactions using two UV tagging reagents namely: 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl for method I and 2,4-dinitrofluorobenzene (DNFB for method II. Both reactions took place in alkaline buffered medium and the obtained yellowish products were measured at 414 and 332 nm for methods I and II, respectively. Methods III and IV are indirect spectrophotometric methods based on the suppressive effect of MSN on the absorption of two ternary complex systems which are composed of 1,10-phenanthroline, silver and eosin for method III and 1,10-phenanthroline, silver and bromopyrogallol red for method IV. The decrease in absorbance of the ternary complexes was measured at 547 and 635 nm for methods III and IV, respectively. All the experimental parameters affecting these reactions were carefully studied and optimized. The methods were validated as per the ICH guidelines. The methods were applicable in the linearity ranges 4–18 μg/mL for method I, 4–16 μg/mL for method II, 0.25–2.25 μg/mL for method III and 0.25–1.75 μg/mL for method IV. The proposed methods were successfully applied for the analysis of MSN in its commercial ampoules and no interference was encountered from the present excipients as indicated by the satisfactory percentage recoveries. The results obtained were in a good agreement with those obtained from a previously published method of the investigated drug.

  13. Developing Initial Response Products Using Data from Optical and SAR Earth Observing Platforms for Natural Disaster Response

    Science.gov (United States)

    Bell, J. R.; Molthan, A.; Dabboor, M.

    2016-12-01

    After a disaster occurs, decision makers require timely information to assist decision making and support. Earth observing satellites provide tools including optical remote sensors that sample in various spectral bands within the visible, near-infrared, and thermal infrared. However, views from optical sensors can be blocked when clouds are present, and cloud-free observations can be significantly delayed depending upon on their repeat cycle. Synthetic aperture radar (SAR) offers several advantages over optical sensors in terms of spatial resolution and the ability to map the Earth's surface whether skies are clear or cloudy. In cases where both SAR and cloud-free optical data are available, these instruments can be used together to provide additional confidence in what is being observed at the surface. This presentation demonstrates cases where SAR imagery can enhance the usefulness for mapping natural disasters and their impacts to the land surface, specifically from severe weather and flooding. The Missouri and Mississippi River flooding from early in 2016 and damage from hail swath in northwestern Iowa on 17 June 2016 are just two events that will be explored. Data collected specifically from the EO-1 (optical), Landsat (optical) and Sentinel 1 (SAR) missions are used to explore several applicable methodologies to determine which products and methodologies may provide decision makers with the best information to provide actionable information in a timely manner.

  14. Sensitive spectrophotometric determination of aceclofenac following azo dye formation with 4-carboxyl-2,6-dinitrobenzene diazonium ion.

    Science.gov (United States)

    Aderibigbe, Segun A; Adegoke, Olajire A; Idowu, Olakunle S; Olaleye, Sefiu O

    2012-01-01

    The study is a description of a sensitive spectrophotometric determination of aceclofenac following azo dye formation with 4-carboxyl-2,6-dinitrobenzenediazonium ion (CDNBD). Spot test and thin layer chromatography revealed the formation of a new compound distinct from CDNBD and aceclofenac. Optimization studies established a reaction time of 5 min at 30 degrees C after vortex mixing the drug/CDNBD for 10 s. An absorption maximum of 430 nm was selected as analytical wavelength. A linear response was observed over 1.2-4.8 μg/mL of aceclofenac with a correlation coefficient of 0.9983 and the drug combined with CDNBD at stoichiometric ratio of 2 : 1. The method has a limit of detection of 0.403 μg/mL, limit of quantitation of 1.22 μg/mL and is reproducible over a three day assessment. The method gave Sandell's sensitivity of 3.279 ng/cm2. Intra- and inter-day accuracies (in terms of errors) were less than 6% while precisions were of the order of 0.03-1.89% (RSD). The developed spectrophotometric method is of equivalent accuracy (p > 0.05) with British Pharmacopoeia, 2010 potentiometric method. It has the advantages of speed, simplicity, sensitivity and more affordable instrumentation and could found application as a rapid and sensitive analytical method of aceclofenac. It is the first described method by azo dye derivatization for the analysis of aceclofenac in bulk samples and dosage forms.

  15. Spectrophotometric determination of silicon in silumin matrix

    International Nuclear Information System (INIS)

    Samanta, Papu; Pandey, K.L.; Kumar, Pradeep; Bagchi, A.C.; Abdulla, K.K.

    2015-01-01

    In dispersion fuel, fissile material is dispersed in inert matrix. Aluminum-silicon-nickel (silumin) alloy is employed as inert matrix owing to its high thermal conductivity, high castability, high corrosion resistance. All these properties depend on the chemical composition and the structure of silumin. Silicon is stringent specification in silumin. A spectrophotometric method has been developed for the determination of silicon content in silumin matrix. Silumin matrix was fused with LiOH and subsequent dissolution in water along with few drops of conc. sulphuric acid. The molybodo-silicic formed by the addition of ammonium molybdate is reduced to molybdenum blue by ascorbic acid in the presence of antimony. The absorbance was measured at 810 nm. Aluminum and nickel were found to be non-interfering with the silicon determination. (author)

  16. Optical observations of the millisecond pulsars PSR 1937+214 and PSR 1953+29

    International Nuclear Information System (INIS)

    Loredo, T.J.; Ricker, G.R.; Rappaport, S.A.; Middleditch, J.

    1984-01-01

    The results of photometric and time-resolved optical observations of the fields of the recently discovered ultra-fast radio pulsars, PSR 1937+214 and PSR 1953+29 (Backer et al. 1982; Boriakoff et al. 1983) are reported. Deep images of the fields reveal no conspicuous optical counterpart for PSR 1937+214, though a star with m/sub r/ approx. 20.5 is coincident with the position of PSR 1953+29. Time-resolved images of the fields of both objects, obtained with a new stroboscopic technique, have yielded upper limits on the pulsed near-infrared emission from each object. Constraints on the physical models for these systems derived from the optical studies are briefly discussed. 25 references, 9 figures, 4 tables

  17. Simultaneous determination of rifampicin, isoniazid and pyrazinamide in tablet preparations by multivariate spectrophotometric calibration.

    Science.gov (United States)

    Goicoechea, H C; Olivieri, A C

    1999-08-01

    The use of multivariate spectrophotometric calibration is presented for the simultaneous determination of the active components of tablets used in the treatment of pulmonary tuberculosis. The resolution of ternary mixtures of rifampicin, isoniazid and pyrazinamide has been accomplished by using partial least squares (PLS-1) regression analysis. Although the components show an important degree of spectral overlap, they have been simultaneously determined with high accuracy and precision, rapidly and with no need of nonaqueous solvents for dissolving the samples. No interference has been observed from the tablet excipients. A comparison is presented with the related multivariate method of classical least squares (CLS) analysis, which is shown to yield less reliable results due to the severe spectral overlap among the studied compounds. This is highlighted in the case of isoniazid, due to the small absorbances measured for this component.

  18. Spectrophotometric determination of boron in water with prior distillation and hydrolysis of the methyl borate

    International Nuclear Information System (INIS)

    Monzo, J.; Pomares, F.; Guardia, M. de la

    1988-01-01

    A procedure for the determination of boron in irrigation waters is proposed, involving the prior distillation and hydrolysis of methyl borate and subsequent spectrophotometric determination with azomethine-H. The selectivity is better than that of the direct analysis method. (author)

  19. Role of Ru(IlI) as an inhibitor in oxidation of lactose by (Cu(bipy)2)2+ in alkaline medium: spectrophotometric and kinetic studies

    International Nuclear Information System (INIS)

    Singh, Ashok Kumar; Singh, Manjula; Srivastava, Jaya; Rahmani, Shahla

    2013-01-01

    Kinetics of oxidation of lactose by (Cu(bipy) 2 ) 2+ in alkaline medium using Ru(III) as an inhibitor has been studied spectrophotometrically at 40 °C. The studies show that the rate of the reaction is zero order with respect to (Cu(bipy) 2 ) 2+ and first order with respect to (lactose). The order of reaction is found to be two at low concentrations of OH - (from 1.48×10 5 to 3.47×10 5 M) and less than two at its high concentrations (from 4.27×10 5 to 6.31×10 5 M). There is a substantial decrease in the pseudo-zero order rate constant with increase in the concentration of Ru(III) chloride, indicating the role of Ru(III) chloride as an inhibitor. Decrease in the rate with increase in dielectric constant of the medium is observed, while ionic strength of the medium and bipyridyl concentration has no influence on the rate. Based on kinetic data and spectrophotometric evidences, a suitable mechanism is proposed for the studied reaction. (author)

  20. Extractive spectrophotometric determination of uranium with malachite green

    International Nuclear Information System (INIS)

    Dubey, S.C.; Nadkarni, M.N.

    1977-01-01

    A sensitive spectrophotometric method based on the extraction of a uranium-benzoate-Malachite Green complex by chlorobenzene is described. The absorption maximum is at 635 nm and the molar absorptivity is 8.3 x 10 4 1. mole -1 cm -1 . A preliminary separation of uranium by extraction with methyl isobutyl ketone from acid-deficient aluminium nitrate solution is used to avoid interferences. An aliquot of the extract in then diluted with chlorobenzene and shaken with benzoate buffer containing Malachite Green (MG). The method has been applied for the determination of uranium in a synthetic leach solution. The complex extracted is probably [U0 2 (C 6 H 5 C00 3 - ][MG + ]. (author)

  1. Near-nucleus optical observations of P/Halley

    International Nuclear Information System (INIS)

    Larson, S.M.

    1987-01-01

    The Near-Nucleus Studies Net of the International Halley Watch has obtained an extensive series of high resolution optical images of P/Halley during its most active phases in 1985-86 which may be useful in interpreting radio observations of Comet Halley. They often show coma structure resulting from anisotropic emission of dust and gas from the inhomogeneous nucleus. Images were obtained in broadband spectral regions to study dust coma morphology, and in medium to narrow spectral bands to isolate the principal emissions of CN, C 3 , C 2 , CO + and H 2 O + . The goals and methods of near-nucleus studies are discussed and recent studies of 1910 images are briefly reviewed. The role of dust jets and cometary activity in P/Halley is discussed and several examples of anisotropic emission of dust during the current apparition are shown. 12 references

  2. Estimation of very low concentrations of Ruthenium by spectrophotometric method using barbituric acid as complexing agent

    International Nuclear Information System (INIS)

    Ramakrishna Reddy, S.; Srinivasan, R.; Mallika, C.; Kamachi Mudali, U.; Natarajan, R.

    2012-01-01

    Spectrophotometric method employing numerous chromogenic reagents like thiourea, 1,10-phenanthroline, thiocyanate and tropolone is reported in the literature for the estimation of very low concentrations of Ru. A sensitive spectrophotometric method has been developed for the determination of ruthenium in the concentration range 1.5 to 6.5 ppm in the present work. This method is based on the reaction of ruthenium with barbituric acid to produce ruthenium(ll)tris-violurate, (Ru(H 2 Va) 3 ) -1 complex which gives a stable deep-red coloured solution. The maximum absorption of the complex is at 491 nm due to the inverted t 2g → Π(L-L ligand) electron - transfer transition. The molar absorptivity of the coloured species is 9,851 dm 3 mol -1 cm -1

  3. Modeling systematic errors: polychromatic sources of Beer-Lambert deviations in HPLC/UV and nonchromatographic spectrophotometric assays.

    Science.gov (United States)

    Galli, C

    2001-07-01

    It is well established that the use of polychromatic radiation in spectrophotometric assays leads to excursions from the Beer-Lambert limit. This Note models the resulting systematic error as a function of assay spectral width, slope of molecular extinction coefficient, and analyte concentration. The theoretical calculations are compared with recent experimental results; a parameter is introduced which can be used to estimate the magnitude of the systematic error in both chromatographic and nonchromatographic spectrophotometric assays. It is important to realize that the polychromatic radiation employed in common laboratory equipment can yield assay errors up to approximately 4%, even at absorption levels generally considered 'safe' (i.e. absorption <1). Thus careful consideration of instrumental spectral width, analyte concentration, and slope of molecular extinction coefficient is required to ensure robust analytical methods.

  4. Stopped-flow injection spectrophotometric method for determination of chlorate in soil

    OpenAIRE

    Jaroon Jakmunee

    2008-01-01

    A stopped-flow injection (FI) spectrophotometric procedure based on iodometric reaction for the determination of chlorate has been developed. Standard/sample was injected into a stream of potassium iodide solution and then merged with a stream of hydrochloric acid solution to produce triiodide. By stopping the flow while the sample zone is being in a mixing coil, a slow reaction of chlorate with iodide in acidic medium was promoted to proceed with minimal dispersion of the triiodide product z...

  5. Linear and non-linear optics of nano-scale 2‧,7‧dichloro-fluorescein/FTO optical system: Bandgap and dielectric analysis

    Science.gov (United States)

    Iqbal, Javed; Yahia, I. S.; Zahran, H. Y.; AlFaify, S.; AlBassam, A. M.; El-Naggar, A. M.

    2016-12-01

    2‧,7‧ dichloro-Fluorescein (DCF) is a promising organic semiconductor material in different technological aspects such as solar cell, photodiode, Schottky diode. DCF thin film/conductive glass (FTO glass) was prepared by a low-cost spin coating technique. The spectrophotometric data such as the absorbance, reflectance and transmittance were cogitated in the 350-2500 nm wavelength range, at the normal incidence. The absorption (n) and linear refractive indices (k) were computed using the Fresnel's equations. The optical band gap was evaluated and it was found that there is two band gap described as follows: (1) It is related to the band gap of FTO/glass which is equal 3.4 eV and (2) the second one is related to the absorption edge of DCF equals 2.25 eV. The non-linear parameters such as the refractive index (n2) and optical susceptibility χ(3) were evaluated by the spectroscopic method based on the refractive index. Both (n2) and χ(3) increased rapidly on increasing the wavelength with redshift absorption. Our work represents a new idea about using FTO glass for a new generation of the optical device and technology.

  6. Radio and optical observations of 0218+357 - The smallest Einstein ring?

    Science.gov (United States)

    O'Dea, Christopher P.; Baum, Stefi A.; Stanghellini, Carlo; Dey, Arjun; Van Breugel, Wil; Deustua, Susana; Smith, Eric P.

    1992-01-01

    VLA radio observations and optical imaging and spectroscopy of the Einstein radio ring 0218+357 are presented. The ring is detected at 22.4 GHz and shows a basically similar structure at 5, 15, and 22.4 GHz. The B component has varied and was about 15 percent brighter in the 8.4 GHz data than in the data of Patnaik et al. (1992). The ring is highly polarized. A weak jetlike feature extending out roughly 2 arcsec to the southeast of component A is detected at 6 cm. The source has amorphous radio structure extending out to about 11 arcsec from the core. For an adopted redshift of 0.68, the extended radio emission is very powerful. The optical spectrum is rather red and shows no strong features. A redshift of about 0.68 is obtained. The identification is a faint compact m(r) about 20 galaxy which extends to about 4.5 arcsec (about 27 kpc). As much as 50 percent of the total light may be due to a central AGN. The observed double core and ring may be produced by an off-center radio core with extended radio structure.

  7. The optical properties of equatorial cirrus in the pilot radiation observation experiment

    Energy Technology Data Exchange (ETDEWEB)

    Platt, C.M.R.; Young, S.A.; Manson, P.; Patterson, G.R. [CSIRO, Victoria (Australia)] [and others

    1996-04-01

    The development of a sensitive filter radiometer for the Atmospheric Radiation Measurement (ARM) Program has been reported. The aim was to develop a reliable and fast instrument that could be used alongside a lidar to obtain near realtime optical properties of clouds, particularly high ice clouds, as they drifted over an ARM Cloud and Radiation Testbed (CART) site allowing calculation of the radiation divergence in the atmosphere over the site. Obtaining cloud optical properties by the lidar/radiometer, or LIRAD, method was described by Platt et al.; the latter paper also describes a year`s data on mid-latitude cirrus. The optical properties of equatorial cirrus (i.e., cirrus within a few degrees of the equator) have hardly been studied at all. The same is true of tropical cirrus, although a few observations have been reported by Davis and Platt et al.This paper describes obersvations performed on cirrus clouds, analysis methods used, and results.

  8. Spectrophotometric study of the complexation equilibria of lanthanum(III) with 1,4-bis(4'-methylanilino)anthraquinone and the determination of lanthanum(III)

    International Nuclear Information System (INIS)

    Idriss, K.A.-R; El-Shahawy, A.S.; Sedaira, H.; Harfoush, A.A.

    1985-01-01

    The complexation equilibria of lanthanum(III) with 1,4-bis(4'-methylanilino)anthraquinone (Quinizarin Green) were studied spectrophotometrically in 40% V/V dimethylformamide using graphical analysis of the absorbance curves. The reaction mechanism of lanthanum with the bisarylaminoanthraquinone dye within the pH range 6 to 9.25 was demonstrated. The thermodynamic stabilities and the molar absorptivities of the complexes formed were determined. The optimum conditions for the spectrophotometric determination of La(III) with this reagent were found. (author)

  9. Spectroscopic observations of Nova Cygni 1975: The coronal line region revisited

    International Nuclear Information System (INIS)

    Ferland, G.J.; Lambert, D.L.; Woodman, J.H.

    1986-01-01

    A synopsis of the McDonald Observatory spectrophotometric observations of Nova Cyg 1975 (V1500 Cyg) is presented. We present these data in a form in which they can be readily accessed in the future, and also study the continous spectrum during the early nebular phase. We show that (1) the remnant probably maintained a luminosity at or above the Eddington limit for at least a year after outburst, (2) free-free emission from the coronal line region made a significant contribution to the optical continuum, and (3) the coronal line region was probably a significant source of ionizing radiation. The energetics of this nova appear to be dominated by the lift-off energy from the white dwarf and radiation from the coronal line region. Thus the light curve of Nova Cyg may tell more about the cooling of the coronal line region than about the decline of the central object. In appendices we discuss the argon abundance of Nova Cyg (less than 8 times solar) and describe how to obtain copies of the McDonald nova data

  10. Selective determination of cyanide complexes of copper, zinc and cadmium in electrolytes by spectrophotometric titration

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Korchagina, O.A.; Samorukova, O.L.

    1986-01-01

    Selective, sensitive and rapid method for determining Cd, Zn, Cu and their mixtures in cyanide electrolytes of galvanic bathes has been developed. Analysis is performed by means of indicator spectrophotometric titration with barium and strontium salts of cadmium cyanide complexes in organic-aqueous solvents

  11. Optical Polarimetry and Radio Observations of PKS1510-089 between 2009 and 2013

    Directory of Open Access Journals (Sweden)

    Pedro P. B. Beaklini

    2018-02-01

    Full Text Available The blazar PKS 1510-089 has shown intense activity at γ -rays in the recent years. In this work, we discussed the results of our 7 mm radio continuum and optical polarimetric monitoring between 2009 and 2013. In 2009, we detected a large rotation of the optical polarization angle that we attributed to the ejection of new polarized components. In 2011, after the occurrence of several γ -rays flares, the radio emission started to increase, reaching values never observed before. We interpreted this increase as the consequence of the superposition of several new components ejected during the γ -rays flares. A delay was measured between the maximum in the radio emission and the γ -ray flares, which favors models involving expanding components like the shock-in-jet models. Finally, we tried to understand the polarization angle variability behavior filling the gaps in our observations with published results of other polarimetric campaigns, and using the criterion of minimum variation in the polarization angle between successive observations to solve the 180° multiplicity.

  12. Batch and flow-injection methods for the spectrophotometric determination of olanzapine

    Energy Technology Data Exchange (ETDEWEB)

    Jasinska, A.; Nalewajko, E

    2004-04-22

    An indirect batch spectrophotometric and direct flow-injection (FI) visible spectrophotometric methods have been developed for the determination of the novel anti-psychotic drug olanzapine (OLA). The batch method is based on the oxidation of olanzapine by a known excess of potassium hexacyanoferrate(III) in the presence of the mixture of sulphuric and phosphoric acids (1:1 (v/v)). The absorbance of unreacted oxidant is measured at 425 nm. The absorbance decreases linearly with increasing concentration of the assayed drug. The FI method with detection at 540 nm is based on the direct oxidation of olanzapine one of two oxidants, cerium(IV) sulphate or potassium hexacyanoferrate(III) in acidic medium. The calibration graph were linear over the range of 2.5-40 {mu}g ml{sup -1} in the batch method and 0.05-300 and 0.5-250 {mu}g ml{sup -1} in the FI methods, used cerium (IV) sulphate and potassium hexacyanoferrate (III) respectively. Both FI methods gave similar results in terms of precision and accuracy. The relative standard deviation (R.S.D.), was <1%. The accuracy, obtained from recovery experiments, was 97.9-99.4%. The batch method gave slightly higher R.S.D. values (up to 2.3%) and lower values of accuracy (the recovery was between 96.5 and 96.6%). The methods developed were applied to the determination of olanzapine in a pharmaceutical product.

  13. DECal: A Spectrophotometric Calibration System For DECam.

    Science.gov (United States)

    Rheault, Jean-Philippe; DePoy, D. L.; Marshall, J. L.; Prochaska, T.; Allen, R.; Wise, J.; Martin, E.

    2012-01-01

    We present preliminary results for a spectrophotometric calibration system that is being implemented as part of the DES DECam project at the Blanco 4 meter at CTIO. Our calibration system uses a 2nm wide tunable source to measure the instrumental response function of the telescope from 300nm up to 1100nm. This calibration will be performed regularly to monitor any change in the transmission function. The system consists of a monochromator based tunable light source that provides illumination on a dome flat that is monitored by calibrated photodiodes and allow us to measure the throughput as a function of wavelength. Our system has an output power of 2 mW, equivalent to a flux of approximately 800 photons/s/pixel on DECam. Preliminary results of the measure of the throughput of the telescope will be presented.

  14. Modeling Optical and Radiative Properties of Clouds Constrained with CARDEX Observations

    Science.gov (United States)

    Mishra, S. K.; Praveen, P. S.; Ramanathan, V.

    2013-12-01

    Carbonaceous aerosols (CA) have important effects on climate by directly absorbing solar radiation and indirectly changing cloud properties. These particles tend to be a complex mixture of graphitic carbon and organic compounds. The graphitic component, called as elemental carbon (EC), is characterized by significant absorption of solar radiation. Recent studies showed that organic carbon (OC) aerosols absorb strongly near UV region, and this faction is known as Brown Carbon (BrC). The indirect effect of CA can occur in two ways, first by changing the thermal structure of the atmosphere which further affects dynamical processes governing cloud life cycle; secondly, by acting as cloud condensation nuclei (CCN) that can change cloud radiative properties. In this work, cloud optical properties have been numerically estimated by accounting for CAEDEX (Cloud Aerosol Radiative Forcing Dynamics Experiment) observed cloud parameters and the physico-chemical and optical properties of aerosols. The aerosol inclusions in the cloud drop have been considered as core shell structure with core as EC and shell comprising of ammonium sulfate, ammonium nitrate, sea salt and organic carbon (organic acids, OA and brown carbon, BrC). The EC/OC ratio of the inclusion particles have been constrained based on observations. Moderate and heavy pollution events have been decided based on the aerosol number and BC concentration. Cloud drop's co-albedo at 550nm was found nearly identical for pure EC sphere inclusions and core-shell inclusions with all non-absorbing organics in the shell. However, co-albedo was found to increase for the drop having all BrC in the shell. The co-albedo of a cloud drop was found to be the maximum for all aerosol present as interstitial compare to 50% and 0% inclusions existing as interstitial aerosols. The co-albedo was found to be ~ 9.87e-4 for the drop with 100% inclusions existing as interstitial aerosols externally mixed with micron size mineral dust with 2

  15. Optical response of the FXG solution to different phantom materials

    International Nuclear Information System (INIS)

    Cavinato, C.C.; Sakuraba, R.K.; Cruz, J.C.; Campos, L.L.

    2011-01-01

    The purpose of this work is to evaluate the performance of the Fricke xylenol gel (FXG) solution developed at IPEN, prepared with 270 Bloom gelatine (made in Brazil), for clinical electron beams to the reference depth, using different phantom materials. The colour change, optical absorption spectra, intra and inter-batches reproducibility, dose-response, lower detection limit, energy and dose rate dependent response and response uniformity were studied. The excellent results obtained indicate the viability of employing this solution in 2D spectrophotometric dosimetry (could be extended to 3D MRI dosimetry) to be applied in quality assurance for clinical radiotherapy treatment planning of superficial tumours being treated with clinical electron beams.

  16. Optical aging observation in suspended core tellurite microstructured fibers under atmospheric conditions

    Science.gov (United States)

    Strutynski, C.; Mouawad, O.; Picot-Clémente, J.; Froidevaux, P.; Désévédavy, F.; Gadret, G.; Jules, J.-C.; Kibler, B.; Smektala, F.

    2017-11-01

    Tellurite glasses are good candidates for the development of broadband supercontinuum (SC) laser sources in the 1-5 μm range. At the moment, beside very few exceptions, SC generation in TeO2-based microstructured optical fibers (MOFs) is limited to 3 μm in the mid-infrared (MIR). We present here an observation of an optical aging occurring in six-hole suspended-core tellurite MOFs. When exposed to atmospheric conditions, such fibers show an alteration of their transmission between 3 and 4 μm. This aging phenomenon leads to the growth of strong additional losses in this wavelengths range over time. Impact of the transmission degradation on spectral broadening is studied through numerical simulations of SC generation.

  17. Extractive spectrophotometric determination of uranium with malachite green

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, S C; Nadkarni, M N [Bhabha Atomic Research Centre, Bombay (India). Fuel Reprocessing Div.

    1977-04-01

    A sensitive spectrophotometric method based on the extraction of a uranium-benzoate-Malachite Green complex by chlorobenzene is described. The absorption maximum is at 635 nm and the molar absorptivity is 8.3 x 10/sup 4/1. mole /sup -1/ cm/sup -1/. A preliminary separation of uranium by extraction with methyl isobutyl ketone from acid-deficient aluminium nitrate solution is used to avoid interferences. An aliquot of the extract in then diluted with chlorobenzene and shaken with benzoate buffer containing Malachite Green (MG). The method has been applied for the determination of uranium in a synthetic leach solution. The complex extracted is probably (U0/sub 2/(C/sub 6/H/sub 5/C00/sub 3//sup -/)(MG/sup +/).

  18. Optical, infrared and radio astronomy from techniques to observation

    CERN Document Server

    Poggiani, Rosa

    2017-01-01

    This textbook presents the established sciences of optical, infrared, and radio astronomy as distinct research areas, focusing on the science targets and the constraints that they place on instrumentation in the different domains. It aims to bridge the gap between specialized books and practical texts, presenting the state of the art in different techniques. For each type of astronomy, the discussion proceeds from the orders of magnitude for observable quantities that drive the building of instrumentation and the development of advanced techniques. The specific telescopes and detectors are then presented, together with the techniques used to measure fluxes and spectra. Finally, the instruments and their limits are discussed to assist readers in choice of setup, planning and execution of observations, and data reduction. The volume also includes worked examples and problem sets to improve student understanding; tables and figures in chapters summarize the state of the art of instrumentation and techniques.

  19. Spectrophotometric method of the determination of gold (III) by using imipramine hydrochloride and promethazine hydrochloride

    International Nuclear Information System (INIS)

    Dembinski, B.; Kurzawa, M.; Szydlowska-Czerniak, A.

    2003-01-01

    Imipramine hydrochloride (IPM.HCl) and promethazine hydrochloride (PMT-HCl) were used for the spectrophotometric determination of gold (III) in the aqueous solution. The halides complexes of gold (III) created a coloured coupling with the studied drugs which were extractable in chloroform. These new compounds were characterized by IR,UV-VIS spectra and thermal and elemental analysis. Rapid and sensitive spectrophotometric method for the determination of gold (III) in the aqueous solution is described. The absorbance was found to be linear function of the gold (III) concentration in the range from 0.2 to 20 x10/sup -1/ mg. The ratio of complex (AuX/sub 4/) to the organic cation from drug in the obtained compounds was determined as 1:1. The method was satisfactorily applied to the analysis of gold (III). A great advantage of the proposed method is that the trace amounts of gold (III) can also be examined. (author)

  20. The kinetics of colour change in textiles and fibres treated with detergent solutions Part II - Spectrophotometric measurements.

    Science.gov (United States)

    Was-Gubala, Jolanta; Grzesiak, Edyta

    2010-06-01

    The aim of this study was to assess colour variations that occur in several types of textiles and their constituent fibres, resulting from the long-term influence of various laundry detergents. A 14-day experiment was conducted using blue, red and grey/black cotton, wool, acrylic and polyester textiles. The spectrophotometric measurement of colour changes in fabric samples and test solutions, as well as the microspectrophotometric analysis of colour changes in single fibres were described. An evaluation of the observed colour changes from a forensic fibre analysis expert's point of view, as well as that of an average user/consumer of the textiles and laundry detergents is also provided. Copyright 2009 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Flow injection methods for the determination of a-tocopherol with spectrophotometric detection

    International Nuclear Information System (INIS)

    Rishi, L.; Waseem, A.; Yaqoob, M.; Nabi, A.; Jadoon, S.

    2011-01-01

    The present paper describes flow injection procedures for a-tocopherol determination in pharmaceuticals and infant milk powder based on spectrophotometric detection. These two procedures are based on the reduction of iron(III) to iron(II) and of Mo(Vi) to Mo(V) by a-tocopherol and subsequent formation of iron(II)-o-phenanthroline, and phospho molybdenum complexes which were monitored at 510 and 695 nm respectively. Calibration graphs were linear over the concentration range of 0.21-43 mu g/mL for iron(III) and 0.25-10 mu g/mL for Mo(Vi) reduction methods respectively. The limits of detection (3s) of 0.05 and 0.1 mu g/mL with sample throughput of 30 and 50/h respectively were obtained. The relative standard deviations of 1.2- 3.8% (n = 4) was achieved in the concentration range studied. The developed methods were applied to pharmaceuticals and infant milk powders and the results obtained were compared with official method and no significant difference between these methods was observed at 95% confidence level. (author)

  2. Automated spectrophotometric bicarbonate analysis in duodenal juice compared to the back titration method.

    Science.gov (United States)

    Erchinger, Friedemann; Engjom, Trond; Gudbrandsen, Oddrun Anita; Tjora, Erling; Gilja, Odd H; Dimcevski, Georg

    2016-01-01

    We have recently evaluated a short endoscopic secretin test for exocrine pancreatic function. Bicarbonate concentration in duodenal juice is an important parameter in this test. Measurement of bicarbonate by back titration as the gold standard method is time consuming, expensive and technically difficult, thus a simplified method is warranted. We aimed to evaluate an automated spectrophotometric method in samples spanning the effective range of bicarbonate concentrations in duodenal juice. We also evaluated if freezing of samples before analyses would affect its results. Patients routinely examined with short endoscopic secretin test suspected to have decreased pancreatic function of various reasons were included. Bicarbonate in duodenal juice was quantified by back titration and automatic spectrophotometry. Both fresh and thawed samples were analysed spectrophotometrically. 177 samples from 71 patients were analysed. Correlation coefficient of all measurements was r = 0.98 (p titration gold standard. This is a major simplification of direct pancreas function testing, and allows a wider distribution of bicarbonate testing in duodenal juice. Extreme values for Bicarbonate concentration achieved by the autoanalyser method have to be interpreted with caution. Copyright © 2016 IAP and EPC. Published by Elsevier India Pvt Ltd. All rights reserved.

  3. SPECTROPHOTOMETRIC DETERMINATION OF CHLOROPHYLLS AND CAROTENOIDS. AN EFFECT OF SONICATION AND SAMPLE PROCESSING

    Directory of Open Access Journals (Sweden)

    Jana Braniša

    2014-02-01

    Full Text Available Chlorophylls and carotenoids are abundant pigments in plants, algae and cyanobacteria. In this study we verified the applicability of two previously developed UV-vis spectrophotometric methods for simultaneous quantitative determination of chlorophylls (a, b and carotenoids (lycopene, β-carotene or total carotenoids. The pigments were extracted from the strawberries, apricots and raspberries in both the acetone-water and acetone-hexane mixtures. Based on the statistical evaluation of the results the combination of mechanical disruption and sonication of fruit samples seems to be a suitable way to improve the pigment extraction efficiency from fruits in both types of solvents. In the case of apricot and raspberry fruit extracts the amount of chlorophylls and carotenoids calculated from the proposed equations was comparable to those published by other authors. However, the spectrophotometric determination of β-carotene content in strawberry acetone-hexane extract appeared to be problematic mainly due to the fact that carotenoids exhibited overlapping chlorophyll absorption bands. Overlap of bands leads to the negative values calculated from the proposed equation for the β-carotene content. The results indicate the limitations in use of the proposed set of equations for plant samples with comparable amounts of studied pigments.

  4. Spectrophotometric Quantification of Vilazodone Hydrochloride in Pharmaceutical Dosage Form Using Quality by Design Approach

    International Nuclear Information System (INIS)

    Panda, S.S.; Kumar, B.V.V.R.K.; Beg, S.; Behera, S.

    2015-01-01

    The present work deals with development and validation of a novel, robust, precise and accurate spectrophotometric method, for the estimation of vilazodone hydrochloride in tablets using the principle of Quality by Design (QbD). A fractional factorial design (FFD) was employed for initial parameter screening. Further the screened parameters were subjected to central composite design (CCD) for evaluating method robustness and method optimization. Different statistical parameters were evaluated to decide appropriateness of experimental data. Vilazodone shows absorption maximum at 285 nm using methanol. Factor screening slit width and sampling interval were identified as critical method variables, which were further evaluated by a CCD. Good linearity was obtained for vilazodone in the range of 5-60 μg/ mL with R"2 > 0.999. The method was found to be accurate with good average % recovery (more than 100 %). Developed method was validated as per ICH guidelines. Based on QbD development of spectrophotometric method ensured that quality is built into the method. The method was robust and can be applied for determination of the vilazodone in pharmaceutical dosage form. (author)

  5. Microchemical analysis of materials based on Y-Ba-Cu by spectrophotometric titration

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Samorukova, O.L.; Zakharov, Eh.K.

    1990-01-01

    A complex method for analysis of superconductor and similar materials on Y-Ba-Cu basis has been developed, which comprises yttrium and copper determination by their indicator spectrophotometric titration by EDTA and/or complexone 4 in the presence of arsenazo 3. The use of complexone 4 is more favourable. Titration is carried out at λ=650 nm. The method has a sufficient accuracy, provides for rapid determination and does not reguire preliminary separation of components

  6. Second order nonlinear optical properties of zinc oxide films deposited by low temperature dual ion beam sputtering

    International Nuclear Information System (INIS)

    Larciprete, M.C.; Passeri, D.; Michelotti, F.; Paoloni, S.; Sibilia, C.; Bertolotti, M.; Belardini, A.; Sarto, F.; Somma, F.; Lo Mastro, S.

    2005-01-01

    We investigated second order optical nonlinearity of zinc oxide thin films, grown on glass substrates by the dual ion beam sputtering technique under different deposition conditions. Linear optical characterization of the films was carried out by spectrophotometric optical transmittance and reflectance measurements, giving the complex refractive index dispersion. Resistivity of the films was determined using the four-point probe sheet resistance method. Second harmonic generation measurements were performed by means of the Maker fringes technique where the fundamental beam was originated by nanosecond laser at λ=1064 nm. We found a relatively high nonlinear optical response, and evidence of a dependence of the nonlinear coefficient on the deposition parameters for each sample. Moreover, the crystalline properties of the films were investigated by x-ray diffraction measurements and correlation with second order nonlinearity were analyzed. Finally, we investigated the influence of the oxygen flow rate during the deposition process on both the second order nonlinearity and the structural properties of the samples

  7. Spectrophotometric Determination of Thorium in Low Grade Minerals and Ores

    Energy Technology Data Exchange (ETDEWEB)

    Arnfelt, A L; Edmundsson, I

    1960-08-15

    The following method is intended for the determination of microgram quantities of thorium in samples of minerals and ores. The mineral sample is decomposed by repeated sintering with sodium peroxide. After digestion with water thorium peroxide hydrate is recovered by centrifugation and dissolved in hydrochloric acid. Thorium is determined spectrophotometrically with naphtarson after its separation from metals forming chloro complexes which are adsorbed on a strongly basic anion exchange resin. Interferences from a few different ions have been studied. The time required for the analysis of one sample is about 4 hours, when analysing 12 samples simultaneously

  8. Spectrophotometric Determination of Thorium in Low Grade Minerals and Ores

    International Nuclear Information System (INIS)

    Arnfelt, A.L.; Edmundsson, I.

    1960-08-01

    The following method is intended for the determination of microgram quantities of thorium in samples of minerals and ores. The mineral sample is decomposed by repeated sintering with sodium peroxide. After digestion with water thorium peroxide hydrate is recovered by centrifugation and dissolved in hydrochloric acid. Thorium is determined spectrophotometrically with naphtarson after its separation from metals forming chloro complexes which are adsorbed on a strongly basic anion exchange resin. Interferences from a few different ions have been studied. The time required for the analysis of one sample is about 4 hours, when analysing 12 samples simultaneously

  9. Comparison of gravimetric and spectrophotometric methods for the determination of O/U ratios in uranium oxides

    International Nuclear Information System (INIS)

    Esteban, Adolfo; Eppis, Maria Rosa

    2004-01-01

    One important parameter to specify in nuclear fuels is the oxygen-metal ratio; many tests were described in literature to determine it. Possibly, gravimetric methods are the most used and usually a good precision was obtained analysing sintered materials. However, the humidity sorbed in the samples and impurities affect these methods, especially in powders. On the other hand, the spectrophotometric methods determine oxygen-uranium ratio by measuring the absorbances of different ionic species in phosphoric acid. This technique is simply and is not affected by humidity and impurities. Owing to discrepancy in the results between both methods, it was carried out in our laboratory, a study on various gravimetric and spectrophotometric methods. Several assays and analysis were performed comparing test procedures, trying to obtain better precision and accuracy. This work presents the results obtained and the recommend procedure to use with sintered and unsintered materials

  10. Optical constants and band edge of amorphous zinc oxide thin films

    International Nuclear Information System (INIS)

    Khoshman, Jebreel M.; Kordesch, Martin E.

    2007-01-01

    The optical characteristics of amorphous zinc oxide (a-ZnO) thin films grown by radio frequency reactive magnetron sputtering on various substrates at temperature -8 -0.32, respectively. The band edge of the films on Si (100) and quartz has been determined by spectroscopic ellipsometry (3.39 ± 0.05 eV) and spectrophotometric (3.35 ± 0.05 eV) methods, respectively. From the angle dependence of the p-polarized reflectivity we deduce a Brewster angle of 60.5 deg. Measurement of the polarized optical properties shows a high transmissivity (81%-99%) and low absorptivity (< 5%) in the visible and near infrared regions at different angles of incidence. Also, we found that there was a higher absorptivity for wavelength < 370 nm. This wavelength, ∼ 370 nm, therefore indicated that the band edge for a-ZnO thin films is about 3.35 eV

  11. Bio-Optical Data Assimilation With Observational Error Covariance Derived From an Ensemble of Satellite Images

    Science.gov (United States)

    Shulman, Igor; Gould, Richard W.; Frolov, Sergey; McCarthy, Sean; Penta, Brad; Anderson, Stephanie; Sakalaukus, Peter

    2018-03-01

    An ensemble-based approach to specify observational error covariance in the data assimilation of satellite bio-optical properties is proposed. The observational error covariance is derived from statistical properties of the generated ensemble of satellite MODIS-Aqua chlorophyll (Chl) images. The proposed observational error covariance is used in the Optimal Interpolation scheme for the assimilation of MODIS-Aqua Chl observations. The forecast error covariance is specified in the subspace of the multivariate (bio-optical, physical) empirical orthogonal functions (EOFs) estimated from a month-long model run. The assimilation of surface MODIS-Aqua Chl improved surface and subsurface model Chl predictions. Comparisons with surface and subsurface water samples demonstrate that data assimilation run with the proposed observational error covariance has higher RMSE than the data assimilation run with "optimistic" assumption about observational errors (10% of the ensemble mean), but has smaller or comparable RMSE than data assimilation run with an assumption that observational errors equal to 35% of the ensemble mean (the target error for satellite data product for chlorophyll). Also, with the assimilation of the MODIS-Aqua Chl data, the RMSE between observed and model-predicted fractions of diatoms to the total phytoplankton is reduced by a factor of two in comparison to the nonassimilative run.

  12. Spectrophotometric Methods for Simultaneous Determination of Oxytetracycline HCl and Flunixin Meglumine in Their Veterinary Pharmaceutical Formulation

    Directory of Open Access Journals (Sweden)

    Hanan A. Merey

    2017-01-01

    Full Text Available Four precise, accurate, selective, and sensitive UV-spectrophotometric methods were developed and validated for the simultaneous determination of a binary mixture of Oxytetracycline HCl (OXY and Flunixin Meglumine (FLU. The first method, dual wavelength (DW, depends on measuring the difference in absorbance (ΔA 273.4–327 nm for the determination of OXY where FLU is zero while FLU is determined at ΔA 251.7–275.7 nm. The second method, first-derivative spectrophotometric method (1D, depends on measuring the peak amplitude of the first derivative selectively at 377 and 266.7 nm for the determination of OXY and FLU, respectively. The third method, ratio difference method, depends on the difference in amplitudes of the ratio spectra at ΔP 286.5–324.8 nm and ΔP 249.6–286.3 nm for the determination of OXY and FLU, respectively. The fourth method, first derivative of ratio spectra method (1DD, depends on measuring the amplitude peak to peak of the first derivative of ratio spectra at 296.7 to 369 nm and 259.1 to 304.7 nm for the determination of OXY and FLU, respectively. Different factors affecting the applied spectrophotometric methods were studied. The proposed methods were validated according to ICH guidelines. Satisfactory results were obtained for determination of both drugs in laboratory prepared mixture and pharmaceutical dosage form. The developed methods are compared favourably with the official ones.

  13. Determination of optical properties in nanostructured thin films using the Swanepoel method

    International Nuclear Information System (INIS)

    Sanchez-Gonzalez, J.; Diaz-Parralejo, A.; Ortiz, A.L.; Guiberteau, F.

    2006-01-01

    We present the methodological framework of the Swanepoel method for the spectrophotometric determination of optical properties in thin films using transmittance data. As an illustrative case study, we determined the refractive index, thickness, absorption index, and extinction coefficient of a nanostructured 3 mol% Y 2 O 3 -doped ZrO 2 (yttria stabilized zirconia, 3YSZ) thin film prepared by the sol-gel method and deposited by dipping onto a soda-lime glass substrate. In addition, using the absorption index obtained with the Swanepoel method, we calculated the optical band gap of the film. The refractive index was found to increase, then decrease, and finally stabilize with increasing wavelength of the radiation, while the absorption index and extinction coefficient decreased monotonically to zero. These trends are explained in terms of the location of the absorption bands. We also deduced that this 3YSZ thin film has a direct optical band gap of 4.6 eV. All these results compared well with those given in the literature for similar thin films. This suggests that the Swanepoel method has an important role to play in the optical characterization of ceramic thin films

  14. Determination of optical properties in nanostructured thin films using the Swanepoel method

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Gonzalez, J. [Departamento de Electronica e Ingenieria Electromecanica, Escuela de Ingenierias Industriales, Universidad de Extremadura, Badajoz 06071 (Spain); Diaz-Parralejo, A. [Departamento de Electronica e Ingenieria Electromecanica, Escuela de Ingenierias Industriales, Universidad de Extremadura, Badajoz 06071 (Spain); Ortiz, A.L. [Departamento de Electronica e Ingenieria Electromecanica, Escuela de Ingenierias Industriales, Universidad de Extremadura, Badajoz 06071 (Spain)]. E-mail: alortiz@unex.es; Guiberteau, F. [Departamento de Electronica e Ingenieria Electromecanica, Escuela de Ingenierias Industriales, Universidad de Extremadura, Badajoz 06071 (Spain)

    2006-06-30

    We present the methodological framework of the Swanepoel method for the spectrophotometric determination of optical properties in thin films using transmittance data. As an illustrative case study, we determined the refractive index, thickness, absorption index, and extinction coefficient of a nanostructured 3 mol% Y{sub 2}O{sub 3}-doped ZrO{sub 2} (yttria stabilized zirconia, 3YSZ) thin film prepared by the sol-gel method and deposited by dipping onto a soda-lime glass substrate. In addition, using the absorption index obtained with the Swanepoel method, we calculated the optical band gap of the film. The refractive index was found to increase, then decrease, and finally stabilize with increasing wavelength of the radiation, while the absorption index and extinction coefficient decreased monotonically to zero. These trends are explained in terms of the location of the absorption bands. We also deduced that this 3YSZ thin film has a direct optical band gap of 4.6 eV. All these results compared well with those given in the literature for similar thin films. This suggests that the Swanepoel method has an important role to play in the optical characterization of ceramic thin films.

  15. Spectrophotometric determination of substrate-borne polyacrylamide.

    Science.gov (United States)

    Lu, Jianhang; Wu, Laosheng

    2002-08-28

    Polyacrylamides (PAMs) have wide application in many industries and in agriculture. Scientific research and industrial applications manifested a need for a method that can quantify substrate-borne PAM. The N-bromination method (a PAM analytical technique based on N-bromination of amide groups and spectrophotometric determination of the formed starch-triiodide complex), which was originally developed for determining PAM in aqueous solutions, was modified to quantify substrate-borne PAM. In the modified method, the quantity of substrate-borne PAM was converted to a concentration of starch-triiodide complex in aqueous solution that was then measured by spectrophotometry. The method sensitivity varied with substrates due to sorption of reagents and reaction intermediates on the substrates. Therefore, separate calibration for each substrate was required. Results from PAM samples in sand, cellulose, organic matter burnt soils, and clay minerals showed that this method had good accuracy and reproducibility. The PAM recoveries ranged from 95.8% to 103.7%, and the relative standard deviations (n = 4) were application and facilitating PAM-related research.

  16. ATPase Activity Measurements by an Enzyme-Coupled Spectrophotometric Assay.

    Science.gov (United States)

    Sehgal, Pankaj; Olesen, Claus; Møller, Jesper V

    2016-01-01

    Enzymatic coupled assays are usually based on the spectrophotometric registration of changes in NADH/NAD(+) or NADPH/NADP(+) absorption at 340 nm accompanying the oxidation/reduction of reactants that by dehydrogenases and other helper enzymes are linked to the activity of the enzymatic reaction under study. The present NADH-ATP-coupled assay for ATPase activity is a seemingly somewhat complicated procedure, but in practice adaptation to performance is easily acquired. It is a more safe and elegant method than colorimetric methods, but not suitable for handling large number of samples, and also presupposes that the activity of the helper enzymes is not severely affected by the chemical environment of the sample in which it is tested.

  17. SPECTROPHOTOMETRIC STUDIES OF SANGUINARINE-Β-CYCLODEXTRIN COMPLEX FORMATION

    Directory of Open Access Journals (Sweden)

    Veaceslav Boldescu

    2008-06-01

    Full Text Available The main aim of this study was to investigate the influence of pH and the presence of hydrophilic polymer polyvinylpyrrolidone on the formation of sanguinarine-β-cyclodextrin (SANG-β-CD inclusion complex. Spectrophotometric studies of the SANG-β-CD systems in the presence and without 0.1 % PVP at the pH 5.0 did not show any evidence of the complex formation. However, the same systems showed several obvious evidences at the pH 8.0: the hyperchromic and the hypochromic effects and the presence of the isosbestic point in the region of 200 – 210 nm. The association constants calculated by three linear methods: Benesi-Hildebrand, Scott and Scatchard, were two times higher for the systems with addition of 0.1% PVP than for the systems without it.

  18. Kinetic Spectrophotometric Determination of Trace Amounts of Sulfide

    Energy Technology Data Exchange (ETDEWEB)

    Barzegar, Mohsen [Tarbiat Modarres University, Tehran (Iran, Islamic Republic of); Jabbari, Ali [K. N. Toosi University, Tehran (Iran, Islamic Republic of); Esmaeili, Majid [Razi University, Kermanshah (Iran, Islamic Republic of)

    2003-09-15

    A method for the determination of trace amount of sulfide based on the addition reaction of sulfide with methyl green at pH 7.5 and 25 .deg. C is described. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 637 nm by the initial rate and fixed time method. The calibration graph is linear in the range 30-1200 ppb. The theoretical limit of detection was 0.014 ppm. Seven replicate analysis of a sample solution containing 0.70 ppm sulfide gave a relative standard deviation of 1.5%. The interfering effects of various ions on sulfide determination have been reported and procedures for removal of interference have been described. The proposed method was applied successfully to the determination of sulfide in tap and wastewater samples.

  19. Kinetic Spectrophotometric Determination of Trace Amounts of Sulfide

    International Nuclear Information System (INIS)

    Barzegar, Mohsen; Jabbari, Ali; Esmaeili, Majid

    2003-01-01

    A method for the determination of trace amount of sulfide based on the addition reaction of sulfide with methyl green at pH 7.5 and 25 .deg. C is described. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 637 nm by the initial rate and fixed time method. The calibration graph is linear in the range 30-1200 ppb. The theoretical limit of detection was 0.014 ppm. Seven replicate analysis of a sample solution containing 0.70 ppm sulfide gave a relative standard deviation of 1.5%. The interfering effects of various ions on sulfide determination have been reported and procedures for removal of interference have been described. The proposed method was applied successfully to the determination of sulfide in tap and wastewater samples

  20. Speciation and spectrophotometric determination of uranium in seawater

    Directory of Open Access Journals (Sweden)

    M. KONSTANTINOU

    2004-06-01

    Full Text Available A series of ion-exchange and extraction procedures for the separation of uranium from seawater samples and subsequent spectrophotometric determination of uranium in seawater by means of arsenazo(III is described. According to the measurements performed by means of traced samples at every stage of separation, the yield of the pre-analytical procedures is generally over 90% and the separation of uranium very selective. The mean uranium concentration in seawater samples collected from five different coastal areas in Cyprus was found to be 3.2 ± 0.2 & micro; g L-1. Uranium in seawater is stable in its hexavalent oxidation state and UO2 (CO334- is the predominant species under normal coastal conditions (pH ≥ 8, EH ≥ 0.35 mV, 1 atm and 0.03% CO2.

  1. FDTD simulated observation of a gold nanorod by scanning near-field optical microscopy

    International Nuclear Information System (INIS)

    Sawada, Keiji; Maruoka, Teruto; Nakamura, Hiroaki; Tamura, Yuichi; Imura, Kohei; Saiki, Toshiharu; Okamoto, Hiromi

    2010-01-01

    The optical properties of a gold nanorod were investigated by Imura et. al. using an apertured-type scanning near-field optical microscope (SNOM). The observed transmission image showed an oscillating pattern along the long axis of the nanorod. We obtain the image using the finite-difference time-domain (FDTD) method. Our model includes a nanorod on a glass substrate, a SNOM, and current as a light source. We develop a simple method for including the Drude-Lorentz dispersion relation of Vial et. al. for gold in the FDTD. The oscillating pattern is explained by the total current in the nanorod, tip of the SNOM, and light source. (author)

  2. Spectrophotometric study of the complexation equilibria of uranium(VI) with 1,4-bis(4'-methylanilino)anthraquinone and determination of uranium(VI)

    International Nuclear Information System (INIS)

    Idriss, K.A.; Seleim, M.M.; Abu-Bakr, M.S.; Sedaira, H.

    1985-01-01

    The reaction of U(VI) with 1,4-bis(4'-methylanilino)anthraquinone (quinizarin green) in water-dimethylformamide medium was investigated spectrophotometrically. The complexation equilibria in solution were demonstrated. The study of the reaction in presence of equimolar concentrations or in solutions containing metal or ligand excess gave evidence for the formation of complexes with stoichiometric ratios of UO 2 :L = 1:1 and 1:2 in dependence on the pH of the medium. Their thermodynamic stabilities and the values of their molar absorption coefficients were determined. The optimum conditions for spectrophotometric determination of U(VI) with this reagent were found. (author)

  3. Sentinel-2: next generation satellites for optical land observation from space

    Science.gov (United States)

    Lautenschläger, G.; Gessner, R.; Gockel, W.; Haas, C.; Schweickert, G.; Bursch, S.; Welsch, M.; Sontag, H.

    2013-10-01

    The first Sentinel-2 satellites, which constitute the next generation of operational Earth observation satellites for optical land monitoring from space, are undergoing completion in the facilities at Astrium ready for launch end 2014. Sentinel-2 will feature a major breakthrough in the area of optical land observation since it will for the first time enable continuous and systematic acquisition of all land surfaces world-wide with the Multi-Spectral Instrument (MSI), thus providing the basis for a truly operational service. Flying in the same orbital plane and spaced at 180°, the constellation of two satellites, designed for an in-orbit nominal operational lifetime of 7 years each, will acquire all land surfaces in only 5 days at the equator. In order to support emergency operations, the satellites can further be operated in an extended observation mode allowing to image any point on Earth even on a daily basis. MSI acquires images in 13 spectral channels from Visible-to-Near Infrared (VNIR) to Short Wave Infrared (SWIR) with a swath of almost 300 km on ground and a spatial resolution up to 10 m. The data ensure continuity to the existing data sets produced by the series of Landsat and SPOT satellites, and will further provide detailed spectral information to enable derivation of biophysical or geophysical products. Excellent geometric image quality performances are achieved with geolocation better than 16 m, thanks to an innovative instrument design in conjunction with a high-performance satellite AOCS subsystem centered around a 2-band GPS receiver, high-performance star trackers and a fiberoptic gyro. To cope with the high data volume on-board, data are compressed using a state-of-the-art wavelet compression scheme. Thanks to a powerful mission data handling system built around a newly developed very large solid-state mass memory based on flash technology, on-board compression losses will be kept to a minimum. The Sentinel-2 satellite design features a highly

  4. Spectrophotometric Analysis of Phosphoric Acid Leakage in High-Temperature Phosphoric Acid-Doped Polybenzimidazole Membrane Fuel Cell Application

    Directory of Open Access Journals (Sweden)

    Seungyoon Han

    2016-01-01

    Full Text Available High-temperature proton exchange membrane fuel cells (HT-PEMFCs utilize a phosphoric acid- (PA- doped polybenzimidazole (PBI membrane as a polymer electrolyte. The PA concentration in the membrane can affect fuel cell performance, as a significant amount of PA can leak from the membrane electrode assembly (MEA by dissolution in discharged water, which is a byproduct of cell operation. Spectrophotometric analysis of PA leakage in PA-doped polybenzimidazole membrane fuel cells is described here. This spectrophotometric analysis is based on measurement of absorption of an ion pair formed by phosphomolybdic anions and the cationoid color reagent. Different color reagents were tested based on PA detection sensitivity, stability of the formed color, and accuracy with respect to the amount of PA measured. This method allows for nondestructive analysis and monitoring of PA leakage during HT-PEMFCs operation.

  5. Anion-exchange enrichment and spectrophotometric determination of uranium in sea-water

    International Nuclear Information System (INIS)

    Kuroda, Rokuro; Oguma, Koichi; Mukai, Noriko; Iwamoto, Masatoshi

    1987-01-01

    A method is proposed for the determination of uranium in sea-water. The uranium is strongly sorbed on a strongly basic anion-exchange resin (Cl - form) from acidified sea-water containing sodium azide (0.3M) and is easily eluted with 1M hydrochloric acid. Uranium in the effluent can be determined spectrophotometrically with Arsenazo III. The combined method allows easy and selective determination of uranium in sea-water without using a sophisticated adsorbent. The overall recovery and precision are satisfactory at the 3 μg/1. level. (author)

  6. Design of the high resolution optical instrument for the Pleiades HR Earth observation satellites

    Science.gov (United States)

    Lamard, Jean-Luc; Gaudin-Delrieu, Catherine; Valentini, David; Renard, Christophe; Tournier, Thierry; Laherrere, Jean-Marc

    2017-11-01

    As part of its contribution to Earth observation from space, ALCATEL SPACE designed, built and tested the High Resolution cameras for the European intelligence satellites HELIOS I and II. Through these programmes, ALCATEL SPACE enjoys an international reputation. Its capability and experience in High Resolution instrumentation is recognised by the most customers. Coming after the SPOT program, it was decided to go ahead with the PLEIADES HR program. PLEIADES HR is the optical high resolution component of a larger optical and radar multi-sensors system : ORFEO, which is developed in cooperation between France and Italy for dual Civilian and Defense use. ALCATEL SPACE has been entrusted by CNES with the development of the high resolution camera of the Earth observation satellites PLEIADES HR. The first optical satellite of the PLEIADES HR constellation will be launched in mid-2008, the second will follow in 2009. To minimize the development costs, a mini satellite approach has been selected, leading to a compact concept for the camera design. The paper describes the design and performance budgets of this novel high resolution and large field of view optical instrument with emphasis on the technological features. This new generation of camera represents a breakthrough in comparison with the previous SPOT cameras owing to a significant step in on-ground resolution, which approaches the capabilities of aerial photography. Recent advances in detector technology, optical fabrication and electronics make it possible for the PLEIADES HR camera to achieve their image quality performance goals while staying within weight and size restrictions normally considered suitable only for much lower performance systems. This camera design delivers superior performance using an innovative low power, low mass, scalable architecture, which provides a versatile approach for a variety of imaging requirements and allows for a wide number of possibilities of accommodation with a mini

  7. DETERMINATION OF PROTOPINE IN FUMARIA DENSIFLORA DC. BY TLC- DENSITOMETRIC AND SPECTROPHOTOMETRIC METHOD

    OpenAIRE

    FAFAL, Tuğçe; ÖNÜR, Mustafa Ali

    2007-01-01

    The isoquinoline alkaloid protopine in Fumaria densiflora DC. (Fumariaceae) was quantitatively determined by TLC-densitometry and spectrophotometry. In TLC-densitometry two different solvent systems as toluene : chloroform : methanol : % 25 ammonium hydroxide (5:3:1:1) and cyclohexane : diethylamine (9:1) were used and protopine was detected as 0.351 and 0.352 % respectively. The content of protopine in Fumaria densiflora DC. was estimated as 0.366 % in spectrophotometric method. The quantita...

  8. Search for neutrinos from transient sources with the ANTARES telescope and optical follow-up observations

    International Nuclear Information System (INIS)

    Ageron, Michel; Al Samarai, Imen; Akerlof, Carl; Basa, Stéphane; Bertin, Vincent; Boer, Michel; Brunner, Juergen; Busto, Jose; Dornic, Damien; Klotz, Alain; Schussler, Fabian; Vallage, Bertrand; Vecchi, Manuela; Zheng, Weikang

    2012-01-01

    The ANTARES telescope is well suited to detect neutrinos produced in astrophysical transient sources as it can observe a full hemisphere of the sky at all the times with a duty cycle close to unity and an angular resolution better than 0.5°. Potential sources include gamma-ray bursts (GRBs), core collapse supernovae (SNe), and flaring active galactic nuclei (AGNs). To enhance the sensitivity of ANTARES to such sources, a new detection method based on coincident observations of neutrinos and optical signals has been developed. A fast online muon track reconstruction is used to trigger a network of small automatic optical telescopes. Such alerts are generated one or two times per month for special events such as two or more neutrinos coincident in time and direction or single neutrinos of very high energy. Since February 2009, ANTARES has sent 37 alert triggers to the TAROT and ROTSE telescope networks, 27 of them have been followed. First results on the optical images analysis to search for GRBs are presented.

  9. Search for neutrinos from transient sources with the ANTARES telescope and optical follow-up observations

    Science.gov (United States)

    Ageron, Michel; Al Samarai, Imen; Akerlof, Carl; Basa, Stéphane; Bertin, Vincent; Boer, Michel; Brunner, Juergen; Busto, Jose; Dornic, Damien; Klotz, Alain; Schussler, Fabian; Vallage, Bertrand; Vecchi, Manuela; Zheng, Weikang

    2012-11-01

    The ANTARES telescope is well suited to detect neutrinos produced in astrophysical transient sources as it can observe a full hemisphere of the sky at all the times with a duty cycle close to unity and an angular resolution better than 0.5°. Potential sources include gamma-ray bursts (GRBs), core collapse supernovae (SNe), and flaring active galactic nuclei (AGNs). To enhance the sensitivity of ANTARES to such sources, a new detection method based on coincident observations of neutrinos and optical signals has been developed. A fast online muon track reconstruction is used to trigger a network of small automatic optical telescopes. Such alerts are generated one or two times per month for special events such as two or more neutrinos coincident in time and direction or single neutrinos of very high energy. Since February 2009, ANTARES has sent 37 alert triggers to the TAROT and ROTSE telescope networks, 27 of them have been followed. First results on the optical images analysis to search for GRBs are presented.

  10. Search for neutrinos from transient sources with the ANTARES telescope and optical follow-up observations

    Energy Technology Data Exchange (ETDEWEB)

    Ageron, Michel [CPPM, CNRS/IN2P3 - Universite de Mediterranee, 163 avenue de Luminy, 13288 Marseille Cedex 09 (France); Al Samarai, Imen, E-mail: samarai@cppm.in2p3.fr [CPPM, CNRS/IN2P3 - Universite de Mediterranee, 163 avenue de Luminy, 13288 Marseille Cedex 09 (France); Akerlof, Carl [Randall Laboratory of Physics, University of Michigan, 450 Church Street, Ann Arbor, MI 48109-1040 (United States); Basa, Stephane [LAM, BP8, Traverse du siphon, 13376 Marseille Cedex 12 (France); Bertin, Vincent [CPPM, CNRS/IN2P3 - Universite de Mediterranee, 163 avenue de Luminy, 13288 Marseille Cedex 09 (France); Boer, Michel [OHP, 04870 Saint Michel de l' Observatoire (France); Brunner, Juergen; Busto, Jose; Dornic, Damien [CPPM, CNRS/IN2P3 - Universite de Mediterranee, 163 avenue de Luminy, 13288 Marseille Cedex 09 (France); Klotz, Alain [OHP, 04870 Saint Michel de l' Observatoire (France); IRAP, 9 avenue du colonel Roche, 31028 Toulouse Cedex 4 (France); Schussler, Fabian; Vallage, Bertrand [CEA-IRFU, centre de Saclay, 91191 Gif-sur-Yvette (France); Vecchi, Manuela [CPPM, CNRS/IN2P3 - Universite de Mediterranee, 163 avenue de Luminy, 13288 Marseille Cedex 09 (France); Zheng, Weikang [Randall Laboratory of Physics, University of Michigan, 450 Church Street, Ann Arbor, MI 48109-1040 (United States)

    2012-11-11

    The ANTARES telescope is well suited to detect neutrinos produced in astrophysical transient sources as it can observe a full hemisphere of the sky at all the times with a duty cycle close to unity and an angular resolution better than 0.5 Degree-Sign . Potential sources include gamma-ray bursts (GRBs), core collapse supernovae (SNe), and flaring active galactic nuclei (AGNs). To enhance the sensitivity of ANTARES to such sources, a new detection method based on coincident observations of neutrinos and optical signals has been developed. A fast online muon track reconstruction is used to trigger a network of small automatic optical telescopes. Such alerts are generated one or two times per month for special events such as two or more neutrinos coincident in time and direction or single neutrinos of very high energy. Since February 2009, ANTARES has sent 37 alert triggers to the TAROT and ROTSE telescope networks, 27 of them have been followed. First results on the optical images analysis to search for GRBs are presented.

  11. Synthesis and different optical properties of Gd2O3 doped sodium zinc tellurite glasses

    Science.gov (United States)

    Samanta, Buddhadev; Dutta, Dibakar; Ghosh, Subhankar

    2017-06-01

    A series of Gd2O3 doped sodium zinc tellurite [xGd2O3-(0.8-x) TeO2-0.1Na2O-0.1ZnO] glasses are prepared by the conventional melt quenching method and their optical properties have been studied. UV-vis spectrophotometric studies within the wavelength range from 230 nm-800 nm are carried out in the integrating sphere mode to study the effect of Gd2O3 doping on the optical band gap (Eg), refractive index (n), dielectric constant (εr) and susceptibility (χ). Other physical properties like molar volume, molar refraction, polarizability, metallization criterion, number density of rare-earth ions (N), polaron radius (rp), inter ionic distance (ri), molar cation polarizability (∑αi), number of oxide ions in chemical composition (NO2-), optical band gap based electronic oxide ion polarizability (αO2-) and optical basicity (Λ) of glass samples have been studied on the basis of UV-vis spectra and density profile of the different glasses.

  12. Preparation, characterization and optical properties of Lanthanum-(nanometer MCM-41) composite materials

    International Nuclear Information System (INIS)

    Zhai, Q. Z.; Wang, P.

    2008-01-01

    Nanometer MCM-41 molecular sieve was prepared under a base condition by using cetyltrimethylammonium bromide as template and tetraethyl orthosilicate as silica source by means of hydrothermal method. Lanthanum(III) was incorporated into the nanometer MCM-41 by a liquid phase grafting method. The prepared nano composite materials were characterized by means of powder X-ray diffraction, spectrophotometric analysis, Fourier transform infrared spectroscopy, low temperature nitrogen adsorption-desorption technique, solid diffuse reflectance absorption spectra and luminescence. The powder X-ray diffraction studies show that the nanometer MCM-41 molecular sieve is successfully prepared. The highly ordered meso porous two-dimensional hexagonal channel structure and framework of the support MCM-41 is retained intact in the prepared composite material La-(nanometer MCM-41). The spectrophotometric analysis indicates that lanthanum exists in the prepared nano composite materials. The Fourier transform infrared spectra indicate that the framework of the MCM-41 molecular sieve still remains in the prepared nano composite materials and some framework vibration peaks show blue shifts relative to those of the MCM-41 molecular sieve. The low temperature nitrogen adsorption-desorption indicates that the guest locales in the channel of the molecular sieve. Compared with bulk lanthanum oxide, the guest in the channel of the molecular sieve has smaller particle size and shows a significant blue shift of optical absorption band in solid diffuse reflectance absorption spectra. The observed blue shift in the solid state diffuse reflectance absorption spectra of the lanthanum-(nanometer MCM-41) sample show the obvious stereoscopic confinement effect of the channel of the host on the guest, which further indicates the successful encapsulation of the guest in the host. The La-(nanometer MCM-41) sample shows luminescence

  13. An Enhanced Method for Scheduling Observations of Large Sky Error Regions for Finding Optical Counterparts to Transients

    Energy Technology Data Exchange (ETDEWEB)

    Rana, Javed; Singhal, Akshat; Gadre, Bhooshan; Bhalerao, Varun; Bose, Sukanta, E-mail: javed@iucaa.in [Inter-University Centre for Astronomy and Astrophysics, Post Bag 4, Ganeshkhind, Pune 411 007 (India)

    2017-04-01

    The discovery and subsequent study of optical counterparts to transient sources is crucial for their complete astrophysical understanding. Various gamma-ray burst (GRB) detectors, and more notably the ground-based gravitational wave detectors, typically have large uncertainties in the sky positions of detected sources. Searching these large sky regions spanning hundreds of square degrees is a formidable challenge for most ground-based optical telescopes, which can usually image less than tens of square degrees of the sky in a single night. We present algorithms for better scheduling of such follow-up observations in order to maximize the probability of imaging the optical counterpart, based on the all-sky probability distribution of the source position. We incorporate realistic observing constraints such as the diurnal cycle, telescope pointing limitations, available observing time, and the rising/setting of the target at the observatory’s location. We use simulations to demonstrate that our proposed algorithms outperform the default greedy observing schedule used by many observatories. Our algorithms are applicable for follow-up of other transient sources with large positional uncertainties, such as Fermi -detected GRBs, and can easily be adapted for scheduling radio or space-based X-ray follow-up.

  14. Determination of dissociation constants for coordination compounds of Cr(III) and Co(III) using potentiometric and spectrophotometric methods

    International Nuclear Information System (INIS)

    Chylewska, A.; Jacewicz, D.; Zarzeczanska, D.; Chmurzynski, L.

    2008-01-01

    The acid-base properties of analogous complex ions of chromium(III) and cobalt(III) in aqueous solution have been studied. The equilibrium constants for all metal complexes were determined by using potentiometric and spectrophotometric titration methods. First, dissociation constants for the studied complexes of Cr(III) and Co(III) were determined by means of the potentiometric titration method and using the STOICHIO computer programme. Then, pH-spectrophotometric titrations were performed and the OriginPro 7.5 computer programme was used to calculate the same constants. The measurements using both methods were carried out under the same conditions of temperature, T = 298.15 K, and over the same pH range 2.00-10.00, respectively. It turned out that the two methods used enabled us to obtain acidity constants in very good agreement

  15. Determination of dissociation constants for coordination compounds of Cr(III) and Co(III) using potentiometric and spectrophotometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Chylewska, A.; Jacewicz, D.; Zarzeczanska, D. [Department of Chemistry, University of Gdansk, Sobieskiego 18/19, 80-952 Gdansk (Poland); Chmurzynski, L. [Department of Chemistry, University of Gdansk, Sobieskiego 18/19, 80-952 Gdansk (Poland)], E-mail: lech@chem.univ.gda.pl

    2008-08-15

    The acid-base properties of analogous complex ions of chromium(III) and cobalt(III) in aqueous solution have been studied. The equilibrium constants for all metal complexes were determined by using potentiometric and spectrophotometric titration methods. First, dissociation constants for the studied complexes of Cr(III) and Co(III) were determined by means of the potentiometric titration method and using the STOICHIO computer programme. Then, pH-spectrophotometric titrations were performed and the OriginPro 7.5 computer programme was used to calculate the same constants. The measurements using both methods were carried out under the same conditions of temperature, T = 298.15 K, and over the same pH range 2.00-10.00, respectively. It turned out that the two methods used enabled us to obtain acidity constants in very good agreement.

  16. Optical Observation of Plasnionic Nonlocal Effects in a 2D Superlattice of Ultrasmall Gold Nanoparticles

    DEFF Research Database (Denmark)

    Shen, Hao; Chen, Li; Ferrari, Lorenzo

    2017-01-01

    in single ultrasmall silver nanopartides have been experimentally observed in single-particle spectroscopy enabled by the unprecedented high spatial resolution of electron energy loss spectroscopy (EELS). However, the unambig-optical observation of such new effects in gold nanopartides has yet not been...... reported, due to the extremely weak scattering and the obscuring fingerprint of strong interband transitions. Here we present a nanosystem, a superlattice monolayer formed by sub-10 nm gold nanopartides. Plasmon resonances are spectrally well-separated from interband transitions, while exhibiting clearly...... distinguishable blue-shifts compared to predictions by the classical local-response model. Our far-field spectroscopy was performed by a standard optical transmission and reflection setup, and the results agreed excellently with the hydrodynamic nonlocal model, opening a simple and Widely accessible way...

  17. Spectrophotometric determination of uranium by previous extraction chromatography separation in polimetalic mineral, phosphorites and technological licours

    International Nuclear Information System (INIS)

    Moreno Bermudez, J.; Cabrera Quevedo, C.; Alfonso Mendez, L.; Rodriguez Aguilera, M.

    1994-01-01

    The development of an analytical procedure for spectrophotometric determination of uranium in polimetalic mineral, phosphorites and technological licours is described. The method is based on the previous separation of interfering elements by extraction chromatography and on spectrophotometric determination of uranium (IV) with arsenazo III in concentrated hydrochloric acid. Tributyl phosphate impregnate on politetrafluoroethylene is used as stationary phase and 5.5 M nitric acid is used as movie phase. The influence of matrix-component elements was studies. The development procedure was applied to real samples, being the results compared with those obtained by other well established analytical methods like gamma-spectrometry, laser fluorimetric, spectrophotometry previous uranium separation by liquid liquid extraction and anion exchange. The reproducibility is evaluated and the detection limited has been established for each studied matrix. A procedure for correcting the thorium interference has been developed for samples with a Th/ 3U8O higher than 0.2

  18. Validation of a spectrophotometric methodology for the quantification of polysaccharides from roots of Operculina macrocarpa (jalapa

    Directory of Open Access Journals (Sweden)

    Marcos A.M. Galvão

    Full Text Available The roots from Operculina macrocarpa (L. Urb., Convolvulaceae, are widely used in Brazilian traditional medicine as a laxative and purgative. The biological properties of this drug material have been attributed to its polysaccharides content. Thus, the aim of this study was to evaluate the polysaccharide content in drug material from O. macrocarpa by spectrophotometric quantitative analysis. The root was used as plant material and the botanical identification was performed by macro and microscopic analysis. The plant material was used to validate the spectrophotometric procedures at 490 nm for the quantification of the reaction product from drug polysaccharides and phenol-sulfuric acid solution. The analytical procedure was evaluated in order to comply with the necessary legal requirements by the determination of the following parameters: specificity, linearity, selectivity, precision, accuracy and robustness. This study provides with a simple and valid analytical procedure (linear, precise, accurate and reproducible, which can be satisfactorily used for quality control and standardization of herbal drug from O. macrocarpa.

  19. Stability indicating spectrophotometric and spectrodensitometric methods for the determination of diatrizoate sodium in presence of its degradation product

    Science.gov (United States)

    Abd El-Rahman, Mohamed K.; Riad, Safaa M.; Abdel Gawad, Sherif A.; Fawaz, Esraa M.; Shehata, Mostafa A.

    2015-02-01

    Three sensitive, selective, and precise stability indicating methods for the determination of the X-ray contrast agent, diatrizoate sodium (DTA), in the presence of its acidic degradation product (highly cytotoxic 3,5 diamino metabolite) and in pharmaceutical formulation were developed and validated. The first method is a first derivative (D1) spectrophotometric one, which allows the determination of DTA in the presence of its degradate at 231.2 nm (corresponding to zero crossing of the degradate) over a concentration range of 2-24 μg/mL with mean percentage recovery 99.95 ± 0.97%. The second method is the first derivative of the ratio spectra (DD1) by measuring the peak amplitude at 227 nm over the same concentration range as D1 spectrophotometric method, with mean percentage recovery 99.99 ± 1.15%. The third method is a TLC-densitometric one, where DTA was separated from its degradate on silica gel plates using chloroform:methanol:ammonium hydroxide (20:10:2 by volume) as a developing system. This method depends on quantitative densitometric evaluation of thin layer chromatogram of DTA at 238 nm over a concentration range of 4-20 μg/spot, with mean percentage recovery 99.88 ± 0.89%. The selectivity of the proposed methods was tested using laboratory-prepared mixtures. The proposed methods have been successfully applied to the analysis of DTA in pharmaceutical dosage forms without interference from other dosage form additives. The results were statistically compared with the official US pharmacopeial method. No significant difference for either accuracy or precision was observed.

  20. The Spectrophotometric Analysis and Modeling of Sunscreens

    Science.gov (United States)

    Walters, Christina; Keeney, Allen; Wigal, Carl T.; Johnston, Cynthia R.; Cornelius, Richard D.

    1997-01-01

    Sunscreens and their SPF (Sun Protection Factor) values are the focus of this experiment that includes spectrophotometric measurements and molecular modeling. Students suspend weighed amounts of sunscreen lotions graded SPF 4, 6, 8, 15, 30, and 45 in water and dissolve aliquots of the aqueous suspensions in propanol. The expected relationship of absorbance proportional to log10(SPF) applies at 312 nm where a maximum in absorbance occurs for the sunscreen solutions. Results at 330 nm give similar results and are more accessible using spectrometers routinely available in the introductory laboratory. Sunscreens constitute a suitable class of compounds to use for modeling electronic spectra, and using the computer for the active ingredients ethylhexyl para-methoxycinnamate, oxybenzone, 2-ethylhexyl salicylate, and octocrylene found in commercially available formulations typically predicts the absorption maxima within 10 nm. This experiment lets students explore which compounds have the potential to function as sunscreen agents and thereby see the importance of a knowledge of chemistry to the formulation of household items.

  1. Validated spectrophotometric methods for determination of Alendronate sodium in tablets through nucleophilic aromatic substitution reactions

    Directory of Open Access Journals (Sweden)

    Walash Mohamed I

    2012-04-01

    Full Text Available Abstract Background Alendronate (ALD is a member of the bisphosphonate family which is used for the treatment of osteoporosis, bone metastasis, Paget's disease, hypocalcaemia associated with malignancy and other conditions that feature bone fragility. ALD is a non-chromophoric compound so its determination by conventional spectrophotometric methods is not possible. So two derivatization reactions were proposed for determination of ALD through the reaction with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl and 2,4-dinitrofluorobenzene (DNFB as chromogenic derivatizing reagents. Results Three simple and sensitive spectrophotometric methods are described for the determination of ALD. Method I is based on the reaction of ALD with NBD-Cl. Method II involved heat-catalyzed derivatization of ALD with DNFB, while, Method III is based on micellar-catalyzed reaction of the studied drug with DNFB at room temperature. The reactions products were measured at 472, 378 and 374 nm, for methods I, II and III, respectively. Beer's law was obeyed over the concentration ranges of 1.0-20.0, 4.0-40.0 and 1.5-30.0 μg/mL with lower limits of detection of 0.09, 1.06 and 0.06 μg/mL for Methods I, II and III, respectively. The proposed methods were applied for quantitation of the studied drug in its pure form with mean percentage recoveries of 100.47 ± 1.12, 100.17 ± 1.21 and 99.23 ± 1.26 for Methods I, II and III, respectively. Moreover the proposed methods were successfully applied for determination of ALD in different tablets. Proposals of the reactions pathways have been postulated. Conclusion The proposed spectrophotometric methods provided sensitive, specific and inexpensive analytical procedures for determination of the non-chromophoric drug alendronate either per se or in its tablet dosage forms without interference from common excipients. Graphical abstract

  2. The structural and optical characterizations of tetraphenylporphyrin thin films

    Energy Technology Data Exchange (ETDEWEB)

    Makhlouf, M.M., E-mail: m_makhlof@hotmail.com [Physics Department, Faculty of Applied Medical Science at Turabah branch, Taif University, Turabah, 21995 (Saudi Arabia); Department of Physics, Faculty of Science at New Damietta, Damietta University, New Damietta 34517 (Egypt); El-Denglawey, A. [Physics Department, Faculty of Applied Medical Science at Turabah branch, Taif University, Turabah, 21995 (Saudi Arabia); Physics Department, Faculty of Science, South Valley University, Qena 83523 (Egypt); Zeyada, H.M. [Department of Physics, Faculty of Science at New Damietta, Damietta University, New Damietta 34517 (Egypt); El-Nahass, M.M. [Physics Department, Faculty of Education, Ain Shams University, Cairo (Egypt)

    2014-03-15

    X-rays diffraction and scanning electron microscope were used to investigate the structural properties of tetraphenylporphyrin, TPP, which is polycrystalline in a synthesized condition. It turns to amorphous structure upon thermal deposition. Annealing temperature ranging from 295 to 473 K does not influence the amorphous structure of films. The optical properties of TPP were investigated using spectrophotometric measurements of the transmittance and reflectance at normal incidence in the wavelength range of 200–2200 nm. The absorption spectra were recorded in UV–visible region of spectra for the as-deposited and annealed samples show different absorption bands, namely four bands labeled as Q-band in visible region of spectra and a more intense band termed as the Soret band in near UV region of spectra. The Soret band shows its splitting (Davydov splitting). Two other bands labeled N and M appear in UV region. The film thickness has no influence on optical properties of films while annealing temperatures have a slight influence on optical properties of TPP films. The type of optical transition in as deposited and annealed conditions of films was found to be indirect allowed band-gap. Both fundamental and onset energy gap decreases upon annealing. -- Highlights: • Tetraphenylporphyrin (TPP) is polycrystalline in powder form, while the as-deposited and annealed TPP thin films have amorphous structure. • The absorption spectra of TPP in UV–visible region consists of Q-bands, Soret band and two other bands labeled N and M. • The optical parameters of TPP thin film were measured. • Thermal annealing influences optical properties of TPP thin films.

  3. The structural and optical characterizations of tetraphenylporphyrin thin films

    International Nuclear Information System (INIS)

    Makhlouf, M.M.; El-Denglawey, A.; Zeyada, H.M.; El-Nahass, M.M.

    2014-01-01

    X-rays diffraction and scanning electron microscope were used to investigate the structural properties of tetraphenylporphyrin, TPP, which is polycrystalline in a synthesized condition. It turns to amorphous structure upon thermal deposition. Annealing temperature ranging from 295 to 473 K does not influence the amorphous structure of films. The optical properties of TPP were investigated using spectrophotometric measurements of the transmittance and reflectance at normal incidence in the wavelength range of 200–2200 nm. The absorption spectra were recorded in UV–visible region of spectra for the as-deposited and annealed samples show different absorption bands, namely four bands labeled as Q-band in visible region of spectra and a more intense band termed as the Soret band in near UV region of spectra. The Soret band shows its splitting (Davydov splitting). Two other bands labeled N and M appear in UV region. The film thickness has no influence on optical properties of films while annealing temperatures have a slight influence on optical properties of TPP films. The type of optical transition in as deposited and annealed conditions of films was found to be indirect allowed band-gap. Both fundamental and onset energy gap decreases upon annealing. -- Highlights: • Tetraphenylporphyrin (TPP) is polycrystalline in powder form, while the as-deposited and annealed TPP thin films have amorphous structure. • The absorption spectra of TPP in UV–visible region consists of Q-bands, Soret band and two other bands labeled N and M. • The optical parameters of TPP thin film were measured. • Thermal annealing influences optical properties of TPP thin films

  4. Observation of vacuum-enhanced electron spin resonance of optically levitated nanodiamonds

    Science.gov (United States)

    Li, Tongcang; Hoang, Thai; Ahn, Jonghoon; Bang, Jaehoon

    Electron spins of diamond nitrogen-vacancy (NV) centers are important quantum resources for nanoscale sensing and quantum information. Combining such NV spin systems with levitated optomechanical resonators will provide a hybrid quantum system for many novel applications. Here we optically levitate a nanodiamond and demonstrate electron spin control of its built-in NV centers in low vacuum. We observe that the strength of electron spin resonance (ESR) is enhanced when the air pressure is reduced. To better understand this novel system, we also investigate the effects of trap power and measure the absolute internal temperature of levitated nanodiamonds with ESR after calibration of the strain effect. Our results show that optical levitation of nanodiamonds in vacuum not only can improve the mechanical quality of its oscillation, but also enhance the ESR contrast, which pave the way towards a novel levitated spin-optomechanical system for studying macroscopic quantum mechanics. The results also indicate potential applications of NV centers in gas sensing.

  5. Ion assisted deposition of refractory oxide thin film coatings for improved optical and structural properties

    International Nuclear Information System (INIS)

    Sahoo, N.K.; Thakur, S.; Bhattacharyya, D.; Das, N.C.

    1999-03-01

    Ion assisted deposition technique (IAD) has emerged as a powerful tool to control the optical and structural properties of thin film coatings. Keeping in view the complexity of the interaction of ions with the films being deposited, sophisticated ion sources have been developed that cater to the need of modern optical coatings with stringent spectral and environmental specifications. In the present work, the results of ion assisted deposition (IAD) of two commonly used refractory oxides, namely TiO 2 and ZrO 2 , using cold cathode ion source (CC-102R) are presented. Through successive feedback and calibration techniques, various ion beams as well as deposition parameters have been optimized to achieve the best optical and structural film properties in the prevalent deposition geometry of the coating system. It has been possible to eliminate the unwanted optical and structural inhomogeneities from these films using and optimized set of process parameters. Interference modulated spectrophotometric and phase modulated ellipsometric techniques have been very successfully utilized to analyze the optical and structural parameters of the films. Several precision multilayer coatings have been developed and are being used for laser and spectroscopic applications. (author)

  6. A QUASAR CATALOG WITH SIMULTANEOUS UV, OPTICAL, AND X-RAY OBSERVATIONS BY SWIFT

    International Nuclear Information System (INIS)

    Wu Jian; Grupe, Dirk; Koch, Scott; Gelbord, Jonathan; Schneider, Donald P.; Gronwall, Caryl; Porterfield, Blair L.; Vanden Berk, Daniel; Wesolowski, Sarah

    2012-01-01

    We have compiled a catalog of optically selected quasars with simultaneous observations in UV/optical and X-ray bands by the Swift Gamma-ray Burst Explorer. Objects in this catalog are identified by matching the Swift pointings with the Sloan Digital Sky Survey Data Release 5 quasar catalog. The final catalog contains 843 objects, among which 637 have both Ultraviolet Optical Telescope (UVOT) and X-Ray Telescope (XRT) observations and 354 of which are detected by both instruments. The overall X-ray detection rate is ∼60% which rises to ∼85% among sources with at least 10 ks of XRT exposure time. We construct the time-averaged spectral energy distribution (SED) for each of the 354 quasars using UVOT photometric measurements and XRT spectra. From model fits to these SEDs, we find that the big blue bump contributes about ∼0.3 dex to the quasar luminosity. We re-visit the α ox -L 2500Å relation by selecting a clean sample with only Type 1 radio-quiet quasars; the dispersion of this relation is reduced by at least 15% compared with studies that use non-simultaneous UV/optical and X-ray data. We only found a weak correlation between L bol /L Edd and α UV . We do not find significant correlations between α x and α ox , α ox and α UV , and α x and log L(0.3-10 keV). The correlations between α UV and α x , α ox and α x , α ox and α UV , L bol /L Edd and α x , and L bol /L Edd and α ox are stronger among low-redshift quasars, indicating that these correlations are likely driven by the changes of SED shape with accretion state.

  7. Spectrophotometric determination of phosphorus in iron alloys employing a flow injection system

    OpenAIRE

    Gervasio,Ana P. G.; Miranda,Carlos E. S.; Luca,Gilmara C.; Tumang,Cristiane A.; Campos,Luis F. P.; Reis,Boaventura F.

    2001-01-01

    A flow-injection procedure for spectrophotometric determination of phosphorus in electrolytic iron and iron alloys is proposed. The method is based on the ammonium molybdate reaction followed by stannous chloride reduction in acidic medium. In order to circumvent the severe interference caused by the major constituents such as Fe(III) and Cr(III), a mini-column packed with AG50W-X8 resin was coupled to the manifold. A sample throughput of 40 determinations per hour, a dynamical range from P 0...

  8. Spectrophotometric determination of trace and ultratrace levels of boron in silicon and chlorosilane samples

    International Nuclear Information System (INIS)

    Chen, J.S.; Lin, H.M.; Yang, M.H.

    1991-01-01

    Spectrophotometric methods for the determination of boron in the low μg/g and ng/g range in high-purity silicon and dichloro- and trichlorosilanes were investigated in detail. The procedures established involve dissolution of silicon samples and the hydrolyzed products of chlorosilane samples in hydrofluoric acid-containing reagents followed by evaporation of the silicon matrix as H 2 SiF 6 . The boron retained in the treated sample solution was then determined by a spectrophotometric method using carminic acid as a chromatic reagent. Special effort has been paid to the control of the analytical blank and reproducible determination of boron. The results indicate that addition of mannitol and proper control of the evaporation process are effective in preventing volatilization of boron during the evaporation of silicon matrix and can thus attain high recovery of boron and reproducible analysis. Through meticulous control of the analytical blank and experimental conditions, the limit of detection for boron determination with the established method can be as low as ng/g levels. Application of the methods to the determination of boron in various stages of purification of silicon and trichlorosilane as well as in borophosphosilicate film was conducted. (orig.)

  9. Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection

    International Nuclear Information System (INIS)

    Yaqoob, M.; Nabi, A.

    2013-01-01

    A simple and sensitive flow injection spectrophotometric method is reported for the room temperature determination of nitrite and nitrate based on the Griess reaction and a copperised cadmium column for reduction of nitrate. Calibration graphs were linear over the range 2 - 1000 micro g N L /sup -1/ (R2 = 0.9997 and 0.9999, n = 9) with a limit of detection (3 s.d.) of 1.0 micro g N L and relative standard deviations (n = 10) of 0.9 and 1.2% for 50 micro g N L nitrite and nitrate respectively. The sample throughput was 50 h. The effect of reagent concentrations, physical parameters (flow rate, sample volume, reaction coil and copperised cadmium column length) and the potential interferences are reported. The effect of salinity on the blank and on the determination of nitrite and nitrate are also presented. The method was applied to natural waters (rainwater, freshwater and estuarine water) and the results for nitrite + nitrate (140 - 7310 micro g N L/sup -1/) were not significantly different (95% confidence interval) from results obtained using a segmented flow analyser reference method with spectrophotometric detection. (author)

  10. Spectrophotometric determination of volautile inorganic hydrides in binary gaseous mixtures

    International Nuclear Information System (INIS)

    Rezchikov, V.G.; Skachkova, I.N.; Kuznetsova, T.S.; Khrushcheva, V.V.

    1985-01-01

    A study was made on possibility of single and continuons analysis of binary mixtures (hydride-gas) for the content of volatile inorganic hydrides (VIH) from absorption spectra in the 185-280 nm band. Dependences of the percentage of VIH transmission on the wavelength are presented. It is shown that the maximum of their absorption depends on the element-hydrogen the bond length and binding energy. Detection limit for boron hydride was established to be n x 10 -3 % vol at 185-190 nm wavelength. Technique for spectrophotometric hydride determination in binary mixtures with hydrogen, argon, helium was developed. The technique provides the continuous control of gaseous mixture composition

  11. Spectrophotometric determination of the first hydrolysis constant of praseodymium (III)

    International Nuclear Information System (INIS)

    Gonzalez M, R.; Lopez G, H.; Rojas H, A.

    2010-01-01

    The behavior of the trivalent ion praseodymium in 2 M of NaCl at 303 K and in CO 2 free conditions, was studied. Spectrophotometric titrations of the soluble species were used, in order to obtain the value of the first hydrolysis constant of Pr(III). The data obtained were treated with both the program Squad and by a graphic method, respectively. The result obtained using Squad was log*β 1 = -8.94 ± 0.03, while it was log*β 1 = -8.77 ± 0.03, when calculated graphically. These results are similar to the value obtained previously with the potentiometric method. (Author)

  12. Spectrophotometric determination of the first hydrolysis constant of praseodymium (III)

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, R.; Lopez G, H. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Rojas H, A., E-mail: hilario.lopez@inin.gob.m [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Departamento de Quimica, Av. San Rafael Atlixco No. 186, Col. Vicentina, 09340 Mexico D. F. (Mexico)

    2010-07-01

    The behavior of the trivalent ion praseodymium in 2 M of NaCl at 303 K and in CO{sub 2} free conditions, was studied. Spectrophotometric titrations of the soluble species were used, in order to obtain the value of the first hydrolysis constant of Pr(III). The data obtained were treated with both the program Squad and by a graphic method, respectively. The result obtained using Squad was log*{beta}{sub 1}= -8.94 {+-} 0.03, while it was log*{beta}{sub 1}= -8.77 {+-} 0.03, when calculated graphically. These results are similar to the value obtained previously with the potentiometric method. (Author)

  13. Spectrophotometric determination of catecholamine using vanadium and eriochrome cyanine r

    International Nuclear Information System (INIS)

    Nagaraja, Padmarajaiah; Shrestha, Ashwinee Kumar; Shivakumar, Anantharaman; Al-Tayar, Naef Ghallab Saeed; Gowda, Avinask K.

    2011-01-01

    highly sensitive spectrophotometric method for the analysis of catecholamine drugs; L-dopa and methyldopa, is described. The analysis is based on the reaction of drug molecules with vanadium (V) which is reduced to vanadium (IV) and form complex with eriochrome cyanine R to give products having maximum absorbance (λ max ) at 565 nm. Beer's law is obeyed in the range 0.028-0.84 and 0.099-0.996 μg mL -1 for L-dopa and methyldopa, respectively. The statistical analysis as well as comparison with reported methods demonstrated high precision and accuracy of the proposed method. The method was successfully applied in the analysis of pharmaceutical preparations. (author)

  14. A prospective, comparative, observational study on optical coherence tomography of the anterior eye segment

    NARCIS (Netherlands)

    Theelen, T.; Hoyng, C.B.

    2013-01-01

    BACKGROUND: We compared two commercially available spectral-domain optical coherence tomography (OCT) devices according to their capacity of imaging the anterior segment of the eye with the same detail and quality. METHODS: A prospective, observational, single-visit study with individuals aged 18

  15. The rapid spectrophotometric determination of vanadium in tool steel with 9(6-methyl-2-pyridyl)azo5

    International Nuclear Information System (INIS)

    Beaupre, P.W.; Holland, W.J.

    1980-01-01

    An extractive-spectrophotometric method for the determination of vanadium in tool steel is described. The only sample pretreatment required is dissolution. An average vanadium of 2.06% was obtained on a standard sample compared to the recommended value of 2.06%. (author)

  16. Apparatus and method of optical marker projection for the three-dimensional shape measurement

    Science.gov (United States)

    Chen, Zhe; Qu, Xinghua; Geng, Xin; Zhang, Fumin

    2015-08-01

    Optical photography measurement and three-dimensional (3-D) scanning measurement have been widely used in the field of the fast dimensional and surface metrology. In the measurement process, however, retro-reflective markers are often pasted on the surface in advance for image registration and positioning the 3-D measuring instruments. For the large-scale workpiece with freeform surface, the process of pasting markers is time consuming, which reduces the measurement efficiency. Meanwhile, the measurement precision is impaired owing to the thickness of the marker. In this paper, we propose a system that projects two-dimensional (2-D) array optical markers with uniform energy on the surface of the workpiece instead of pasting retro-reflective markers, which achieves large-range and automated optical projection of the mark points. In order to conjunction with the 3-D handheld scanner belonging to our team, we develop an apparatus of optical marker projection, which is mainly composed of the high-power laser, the optical beam expander system, adjustable aperture stop and Dammann grating of dibasic spectrophotometric device. The projection apparatus can achieve the function of beams of 15 * 15 uniformly light of the two-dimensional lattice. And it's much cheaper than the existing systems.

  17. Optical observations on critical ionization velocity experiments in space

    International Nuclear Information System (INIS)

    Stenbaek-Nielsen, H.C.

    1993-01-01

    A number of Critical Ionization Velocity (CIV) experiments have been performed in space. CIV has been observed in laboratory experiments, but experiments in space have been inconclusive. Most space experiments have used barium which ionizes easily, and with emission lines from both neutrals and ions in the visible optical observations can be made from the ground. Also other elements, such as xenon, strontium and calcium, have been used. High initial ionization in some barium release experiments has been claimed due to CIV. However, a number of reactions between barium and the ambient plasma have been suggested as more likely processes. Currently the most popular process in this debate is charge exchange with O + . This process has a large cross section, but is it large enough? The cross section for charge exchange with calcium should be even larger, but in a double release of barium and calcium (part of the NASA CRRES release experiments) most ionization was observed from the barium release. Moreover, if charge exchange is the dominant process, the amount of ionization should relate to the oxygen ion density, and that does not appear to be the case. Other processes, such as associative ionization, have also been proposed, but yields are uncertain because the reaction rates are very poorly known

  18. A New Technique for Quantitative Determination of Dexamethasone in Pharmaceutical and Biological Samples Using Kinetic Spectrophotometric Method

    Directory of Open Access Journals (Sweden)

    Ali Mohammad Akhoundi-Khalafi

    2015-01-01

    Full Text Available Dexamethasone is a type of steroidal medications that is prescribed in many cases. In this study, a new reaction system using kinetic spectrophotometric method for quantitative determination of dexamethasone is proposed. The method is based on the catalytic effect of dexamethasone on the oxidation of Orange G by bromate in acidic media. The change in absorbance as a criterion of the oxidation reaction progress was followed spectrophotometrically. To obtain the maximum sensitivity, the effective reaction variables were optimized. Under optimized experimental conditions, calibration graph was linear over the range 0.2–54.0 mg L−1. The calculated detection limit (3sb/m was 0.14 mg L−1 for six replicate determinations of blank signal. The interfering effect of various species was also investigated. The present method was successfully applied for the determination of dexamethasone in pharmaceutical and biological samples satisfactorily.

  19. Spectrophotometric determination of triclosan in personal care products

    Science.gov (United States)

    Lu, Huihui; Ma, Hongbing; Tao, Guanhong

    2009-09-01

    A spectrophotometric method for the determination of triclosan in personal care products was proposed. It was based on the reaction of sodium nitrite with p-sulfanilic acid in an acidic medium to form diazonium ion, with which triclosan further formed an azo compound in an alkaline medium. The resulting yellow colored product has a maximum absorption at 452 nm. A good linear relationship ( r = 0.9999) was obtained in the range of 0-30 mg L -1 triclosan. A detection limit of 0.079 g L -1 was achieved and the relative standard deviation was 0.24% ( n = 11) at 14 mg L -1 triclosan. The proposed method has been applied to the analyses of triclosan in several personal care products and the results were in good agreement with those obtained by high-performance liquid chromatography.

  20. Extraction-spectrophotometric study of ruthenium (4) and osmium (4,8) reaction with 2-mercaptobenzimidazole, 2-mercaptobenzoxazole and 2-mercaptobenzothiazole in acetate buffer solutions

    Energy Technology Data Exchange (ETDEWEB)

    Lomakina, L N; Ignat' eva, T I; Busev, A I [Moskovskij Gosudarstvennyj Univ. (USSR)

    1978-03-01

    The complex formation of Ru(4) and Os(4, 8) with 2-mercaptobenzimidazole (MBI), 2-mercaptobenzoxazole (MBO) and 2-mercaptobenzothiazole (MBT) has been studied spectrophotometrically in acetate buffer solutions. As it has been shown earlier, Os and Ru react with the reagents in the oxidation state of three . Compound polinuclear structures of Ru and Os with MBI and MBO are suggested. A spectrophotometric procedure has been developed of determining Ru and Os (>=10/sup -4/%) with MBO in natural and industrial materials after selective absorption of the tetraoxides during distillation.

  1. Spectrophotometric studies on complex formation of 5-nitro-3-sulpho-salicylic acid with niobium(V)

    International Nuclear Information System (INIS)

    Parmar, D.S.; Shivahare, G.C.

    1975-01-01

    5-nitro-3-sulpho-salicylic acid forms a yellow complex witn niobium(V) at pH 9.9 and the reaction has been successfully studied spectrophotometrically. The results of the Job's continuous variation method and the mole ratio method indicate a composition of 1:2 for the complex. Stability constant of the complex has also been determined. (author)

  2. Spectrophotometric studies on complex formation of 5-nitro-3-sulpho-salicylic acid with niobium(V)

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, D S; Shivahare, G C [Rajasthan Univ., Jaipur (India). Dept. of Chemistry

    1975-11-01

    5-nitro-3-sulpho-salicylic acid forms a yellow complex witn niobium(V) at pH 9.9 and the reaction has been successfully studied spectrophotometrically. The results of the Job's continuous variation method and the mole ratio method indicate a composition of 1:2 for the complex. Stability constant of the complex has also been determined.

  3. Optical sensors for earth observation. Chikyu kansokuyo kogaku sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ono, A [National Research Laboratory of Metrology, Tsukuba (Japan)

    1991-10-10

    Developments are made on an optical imager (ASTER) used to collect mainly images of land areas and an infrared sounder (IMG) to measure vertical air temperature distribution and vertical concentration distribution of specific gases, as satellite mounted sensors for earth observation. All the sensor characteristics of the ASTER comprising a visible near infrared radiometer, short wave infrared radiometer and thermal infrared radiometer are required to be capable of providing measurement, evaluation and assurance at the required accuracies during the entire life time. A problem to be solved is how to combine the on-ground calibration prior to launching, on-satellite calibration, and calibration between the test site and the sensors. The IMG is a Fourier transform spectroscopic infrared sounder, which is demanded of a high wave resolution over extended periods of time as well as a high radiation measuring capability. Also required are the level elevation of analysis algorithms to solve inverse problems from the observed radiation spectra, and the data base with high accuracy. 19 refs., 4 figs., 4 tabs.

  4. Measurement of Capsaicinoids in Chiltepin Hot Pepper: A Comparison Study between Spectrophotometric Method and High Performance Liquid Chromatography Analysis

    Directory of Open Access Journals (Sweden)

    Alberto González-Zamora

    2015-01-01

    Full Text Available Direct spectrophotometric determination of capsaicinoids content in Chiltepin pepper was investigated as a possible alternative to HPLC analysis. Capsaicinoids were extracted from Chiltepin in red ripe and green fruit with acetonitrile and evaluated quantitatively using the HPLC method with capsaicin and dihydrocapsaicin standards. Three samples of different treatment were analyzed for their capsaicinoids content successfully by these methods. HPLC-DAD revealed that capsaicin, dihydrocapsaicin, and nordihydrocapsaicin comprised up to 98% of total capsaicinoids detected. The absorbance of the diluted samples was read on a spectrophotometer at 215–300 nm and monitored at 280 nm. We report herein the comparison between traditional UV assays and HPLC-DAD methods for the determination of the molar absorptivity coefficient of capsaicin (ε280=3,410 and ε280=3,720 M−1 cm−1 and dihydrocapsaicin (ε280=4,175 and ε280=4,350 M−1 cm−1, respectively. Statistical comparisons were performed using the regression analyses (ordinary linear regression and Deming regression and Bland-Altman analysis. Comparative data for pungency was determined spectrophotometrically and by HPLC on samples ranging from 29.55 to 129 mg/g with a correlation of 0.91. These results indicate that the two methods significantly agree. The described spectrophotometric method can be routinely used for total capsaicinoids analysis and quality control in agricultural and pharmaceutical analysis.

  5. Ionospheric Electron Heating Associated With Pulsating Auroras: Joint Optical and PFISR Observations

    Science.gov (United States)

    Liang, Jun; Donovan, E.; Reimer, A.; Hampton, D.; Zou, S.; Varney, R.

    2018-05-01

    In a recent study, Liang et al. (2017, https://doi.org/10.1002/2017JA024127) repeatedly identified strong electron temperature (Te) enhancements when Swarm satellites traversed pulsating auroral patches. In this study, we use joint optical and Poker Flat Incoherent Scatter Radar (PFISR) observations to further investigate the F region plasma signatures related to pulsating auroras. On 19 March 2015 night, which contained multiple intervals of pulsating auroral activities, we identify a statistical trend, albeit not a one-to-one correspondence, of strong Te enhancements ( 500-1000 K) in the upper F region ionosphere during the passages of pulsating auroras over PFISR. On the other hand, there is no discernible and repeatable density enhancement in the upper F region during pulsating auroral intervals. Collocated optical and NOAA satellite observations suggest that the pulsating auroras are composed of energetic electron precipitation with characteristic energy >10 keV, which is inefficient in electron heating in the upper F region. Based upon PFISR observations and simulations from Liang et al. (2017) model, we propose that thermal conduction from the topside ionosphere, which is heated by precipitating low-energy electrons, offers the most likely explanation for the observed electron heating in the upper F region associated with pulsating auroras. Such a heating mechanism is similar to that underlying the "stable auroral red arcs" in the subauroral ionosphere. Our proposal conforms to the notion on the coexistence of an enhanced cold plasma population and the energetic electron precipitation, in magnetospheric flux tubes threading the pulsating auroral patch. In addition, we find a trend of enhanced ion upflows during pulsating auroral intervals.

  6. Simultaneous X-ray, ultraviolet, and optical observations of the BL Lacertae object PKS 2155-304

    International Nuclear Information System (INIS)

    Treves, A.; Morini, M.; Chiappetti, L.; Fabian, A.; Falomo, R.

    1989-01-01

    A series of observations at optical, UV, and X-ray frequencies of PKS 2155-304, one of the brightest BL Lac objects is reported. Spectral fits given for various epochs show that the medium energy data are well fitted by single power laws plus absorption, with energy index between 1.5 and 2. Marginal evidence for an absorption edge at about 7 keV is found, as is evidence for some spectral depression at about 1 keV. This may be modeled with an edge at 660 + or - 26 eV with optical depth tau = 1.8 + or - 0.2. Energy distributions on several occasions are reconstructed, and the optical, UV, and X-ray intensities are found to be correlated in all cases but one. The variability amplitudes decrease and the time scales increase with decreasing frequency. These results indicate a synchrotron origin for the X-rays and distinct but connected emission regions for the X-ray, UV, and optical bands. 46 refs

  7. X-ray and optical observations of the ultrashort period dwarf nova SW Ursae Majoris - A likely new DQ Herculis star

    Science.gov (United States)

    Shafter, A. W.; Szkody, P.; Thorstensen, J. R.

    1986-01-01

    Time-resolved X-ray and optical photometric and optical spectroscopic observations of the ultrashort period cataclysmic variable SW UMa are reported. The spectroscopic observations reveal the presence of an s-wave component which is almost in phase with the extreme line wings and presumably the white dwarf. This very unusual phasing in conjunction with the available optical and X-ray data seems to indicate that a region of enhanced emission exists on the opposite side of the disk from the expected location of the hot spot. The photometric observations reveal the presence of a hump in the light curve occurring at an orbital phase which is consistent with the phase at which the region of enhanced line emission is most favorably seen. Changes in the hump amplitude are seen from night to night, and a 15.9 min periodicity is evident in the light curve. The optical and X-ray periodicities suggest that SW UMa is a member of the DQ Her class of cataclysmic variables.

  8. History of initial fifty years of ARIES: A Major National Indian Facility for Optical Observations

    Science.gov (United States)

    Sanwal, Basant Ballabh; Pandey, Anil Kumar; Uddin, Wahab; Kumar, Brijesh; Joshi, Santosh

    2018-04-01

    The idea of starting an astronomical observatory in the state of Uttar Pradesh in India germinated through the initiative of a scholarly statesman Babu Sampurnanandji. His interest in astrology coupled with his academic bent of mind got him interested in modern astronomy. Being then Education Minister and later Chief Minister of Uttar Pradesh, he established an astronomical observatory at Varanasi on April 20, 1954. Later on it was shifted to Manora Peak, Nainital. Four reflectors were commissioned at Manora Peak. For solar research an H alpha petrol unit and a horizontal solar spectrograph was setup. A detailed project report for installation of a 4-m class optical telescope was prepared indigenously in late 1980, however, the project could not take off. With the generous support of the Department of Science and Technology, the institute established a 3.6-m new technology optical telescope and a 1.3-m wide field optical telescope at a new observing site called Devasthal. Now a 4-m liquid mirror telescope is also being installed at the same observing site. I present here a brief journey of the observatory beginning right from its birth in 1954 till now.

  9. Spectrophotometric determination of hydrogen peroxide with osmium(VIII) and m-carboxyphenylfluorone.

    Science.gov (United States)

    Hoshino, Mitsuru; Kamino, Shinichiro; Doi, Mitsunobu; Takada, Shingo; Mitani, Shota; Yanagihara, Rika; Asano, Mamiko; Yamaguchi, Takako; Fujita, Yoshikazu

    2014-01-03

    Spectrophotometric determination of hydrogen peroxide was accomplished with osmium(VIII) and m-carboxyphenylfluorone (MCPF) in the presence of cetyltrimethylammonium chloride (CTAC). In the determination of hydrogen peroxide based on the fading of the color of osmium(VIII)-MCPF complex, Beer's law was obeyed in the range 20-406 ng mL(-1), with an effective molar absorption coefficient (at 580 nm) of 5.21×10(4) L mol(-1) cm(-1) and a relative standard deviation of 0.33% (n=6). Further, we performed the characterization of MCPF and obtained the crystal structure. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Determination of niobium in rocks by an isotope dilution spectrophotometric method

    Science.gov (United States)

    Greenland, L.P.; Campbell, E.Y.

    1970-01-01

    Rocks and minerals are fused with sodium peroxide in the presence of carrierfree 95Nb. The fusion cake is leached with water and the precipitate dissolved in hydrofluoric-sulfuric acid mixture. Niobium is extracted into methyl isobutyl ketone and further purified by ion exchange. The amount of niobium is determined spectrophotometrically with 4-(2-pyridylazo)-resorcinol, and the chemical yield of the separations determined by counting 95Nb. This procedure is faster and less sensitive to interferences than previously proposed methods for determining niobium in rocks.The high purity of the separated niobium makes the method applicable to nearly all matrices. ?? 1970.

  11. Observation of the Dynamical Inversion of the Topological Charge of an Optical Vortex

    International Nuclear Information System (INIS)

    Molina-Terriza, Gabriel; Recolons, Jaume; Torres, Juan P.; Torner, Lluis; Wright, Ewan M.

    2001-01-01

    We report what is believed to be the first detailed experimental observation of the dynamic inversion of the topological charge of an optical vortex under free-space propagation. The vortex self-transformation occurs through continuous deformation of the noncanonical strength of the corresponding screw wave front dislocation, and is mediated by the occurrence of an extremely sharp turn in a Berry vortex trajectory, which observed at a Freund critical foliation appears as an edge-line dislocation orthogonal to the propagation direction, at a crucial point of the light evolution

  12. Novel Spectrophotometric Method for the Determination of Pindolol in Pharmaceutical Samples

    Science.gov (United States)

    Nagaraja, P.; Kumar, H. R. Arun; Bhaskara, B. L.; Kumar, S. Anil

    2011-10-01

    A new facile and sensitive spectrophotometric determination of Pindolol (PDL), a beta blocker drug has been developed and validated. The method was based on the reaction between pindolol and K3 [Fe(CN)6] in presence of FeCl3 to form Prussian blue. The absorbance values were recorded at 700 nm and a calibrated graph was constructed. A dynamic Beer's law range was observed in the range 0.125-2.5 μg mL-1 with a detection limit of 0.03 μg mL-1 and a quantitation limit of 0.08 μg mL-1. Various experimental parameters such as effect of solvents, stability, interference effects due to excipients etc were studied. The reproducibility of this methods were checked by six replicate determinations at 1.0 μg ml-1 PDL and the standard deviation was found to be between 0.20 and 0.42%. The results were statistically compared with those of the reference/literature method by applying Student's t-test and F-test. The sensitivity, simplicity, temperature independence and stability of the colored product are the advantages of the proposed method and it is also free from extraction steps and use of carcinogenic solvents.

  13. Ultraviolet and optical observations of the dwarf novae VW and WX Hydri during outburst

    International Nuclear Information System (INIS)

    Hassall, B.J.M.; Pringle, J.E.; Schwarzenberge-Czerny, A.; Wade, R.A.; Whelan, J.A.J.; Hill, P.W.

    1983-01-01

    Simultaneous spectrophotometry in the range 1200-7000 A, of the dwarf novae at quiescence and maximum is presented. The continuum spectra are compared with the standard model disc spectrum and, with one exception, the fit is poor. The assumptions that the disc is both steady-state and blackbody are reconsidered and it is pointed out that a νsup(1/3) spectrum is not to be expected from a disc sufficiently small to be accommodated within these short binary period systems. On the rise to outburst the UV flux in VW Hydri is observed to lag at least one day behind the optical, supporting the mass accretion event explanation of dwarf nova outbursts. The behaviour of the UV and optical line features during outbursts is described, in particular, the P Cygni features observed in a super-outburst of WX Hydri, from which a mass loss rate is estimated, small compared with the mass transfer rate from the secondary star. (author)

  14. Effect of some colloid surfactants on spectrophotometric characteristics of metal chelates with chromophore organic reagents

    International Nuclear Information System (INIS)

    Chernova, R.K.

    1977-01-01

    Theoretical regularities and prospects of using surface active substances (SAS) in spectrophotometric determination of metal ions (including ions of rare-earth elements, transition metals, Be(3)) with chromophore chelating reagents were investigated. The chromophore reagents investigated were pyrocatechol violet, phenolcarboxylic acids of the triarylmethane series, fluorones, phthalexones and azo-compounds. As SAS certain long-chain quaternary ammonium and pyridinium salts (LQAS) were employed. From the results reported it follows that the introduction of LQAS in the system of Mesup(n+)-chromophore reagent is a rather effective method of enhancing the contrast rendition and, in some cases, the sensitivity and selectivity of the reagents. Explanations are suggested as to the factors which cause the changes observed in the contrast of the reactions in the presence of SAS; the underlying phenomena are the ligand-ligand interactions between the organic reagents and SAS and solubilization processes of the reaction products by the micelles of SAS

  15. Purohit's spectrophotometric method for determination of stability constants of complexes using Job's curves

    International Nuclear Information System (INIS)

    Purohit, D.N.; Goswami, A.K.; Chauhan, R.S.; Ressalan, S.

    1999-01-01

    A spectrophotometric method for determination of stability constants making use of Job's curves has been developed. Using this method stability constants of Zn(II), Cd(II), Mo(VI) and V(V) complexes of hydroxytriazenes have been determined. For the sake of comparison, values of the stability constants were also determined using Harvey and Manning's method. The values of the stability constants developed by two methods compare well. This new method has been named as Purohit's method. (author)

  16. Acceptability criteria for linear dependence in validating UV-spectrophotometric methods of quantitative determination in forensic and toxicological analysis

    Directory of Open Access Journals (Sweden)

    L. Yu. Klimenko

    2014-08-01

    Full Text Available Introduction. This article is the result of authors’ research in the field of development of the approaches to validation of quantitative determination methods for purposes of forensic and toxicological analysis and devoted to the problem of acceptability criteria formation for validation parameter «linearity/calibration model». The aim of research. The purpose of this paper is to analyse the present approaches to acceptability estimation of the calibration model chosen for method description according to the requirements of the international guidances, to form the own approaches to acceptability estimation of the linear dependence when carrying out the validation of UV-spectrophotometric methods of quantitative determination for forensic and toxicological analysis. Materials and methods. UV-spectrophotometric method of doxylamine quantitative determination in blood. Results. The approaches to acceptability estimation of calibration models when carrying out the validation of bioanalytical methods is stated in international papers, namely «Guidance for Industry: Bioanalytical method validation» (U.S. FDA, 2001, «Standard Practices for Method Validation in Forensic Toxicology» (SWGTOX, 2012, «Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs in Seized Materials and Biological Specimens» (UNODC, 2009 and «Guideline on validation of bioanalytical methods» (ЕМА, 2011 have been analysed. It has been suggested to be guided by domestic developments in the field of validation of analysis methods for medicines and, particularly, by the approaches to validation methods in the variant of the calibration curve method for forming the acceptability criteria of the obtained linear dependences when carrying out the validation of UV-spectrophotometric methods of quantitative determination for forensic and toxicological analysis. The choice of the method of calibration curve is

  17. Indirect spectrophotometric determination of sulfadiazine based on localized surface plasmon resonance peak of silver nanoparticles after cloud point extraction.

    Science.gov (United States)

    Kazemi, Elahe; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Fattahi, Mohammad Reza; Khodaveisi, Javad

    2017-12-05

    A novel, efficient, easy to use, environmentally friendly and cost-effective methodology is developed for the indirect spectrophotometric determination of sulfadiazine in different samples. The method is based on the micelle-mediated extraction of silver sulfadiazine and converting the silver content of the resultant surfactant-rich phase to the silver nanoparticles via generation of [Ag(NH 3 ) 2 ] + followed by its chemical reduction using ascorbic acid. The changes in the amplitude of localized surface plasmon resonance peak of silver nanoparticles as a function of sulfadiazine concentration in the sample solution was monitored using fiber optic linear array spectrophotometry at 457nm. The experimental conditions were thoroughly investigated and optimized. Under the optimized condition, the developed procedure showed dynamic linear calibration within the range of 10.0-800.0μgL -1 with a detection limit of 2.8μgL -1 for sulfadiazine. The relative standard deviation of the method for six replicate measurements at 150.0μgL -1 of sulfadiazine was 4.7%. The developed method was successfully applied to the determination of sulfadiazine in different samples including well water, human urine, milk and pharmaceutical formulation. Copyright © 2017. Published by Elsevier B.V.

  18. Indirect spectrophotometric determination of sulfadiazine based on localized surface plasmon resonance peak of silver nanoparticles after cloud point extraction

    Science.gov (United States)

    Kazemi, Elahe; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Fattahi, Mohammad Reza; Khodaveisi, Javad

    2017-12-01

    A novel, efficient, easy to use, environmentally friendly and cost-effective methodology is developed for the indirect spectrophotometric determination of sulfadiazine in different samples. The method is based on the micelle-mediated extraction of silver sulfadiazine and converting the silver content of the resultant surfactant-rich phase to the silver nanoparticles via generation of [Ag(NH3)2]+ followed by its chemical reduction using ascorbic acid. The changes in the amplitude of localized surface plasmon resonance peak of silver nanoparticles as a function of sulfadiazine concentration in the sample solution was monitored using fiber optic linear array spectrophotometry at 457 nm. The experimental conditions were thoroughly investigated and optimized. Under the optimized condition, the developed procedure showed dynamic linear calibration within the range of 10.0-800.0 μg L- 1 with a detection limit of 2.8 μg L- 1 for sulfadiazine. The relative standard deviation of the method for six replicate measurements at 150.0 μg L- 1 of sulfadiazine was 4.7%. The developed method was successfully applied to the determination of sulfadiazine in different samples including well water, human urine, milk and pharmaceutical formulation.

  19. Ocean Health X-Prize testing of a Simplified Spectrophotometric pH Sensor

    Science.gov (United States)

    Darlington, R. C.; DeGrandpre, M. D.; Spaulding, R. S.; Beck, J. C.

    2016-02-01

    Since the Industrial Revolution, the world's oceans have absorbed increasing amounts of CO2, resulting in a >0.1 reduction in the pH of surface waters. This acidification of the oceans has many far reaching impacts on marine life. There is, therefore, great need of quality instrumentation to assess and follow the changing carbonate system. To address this need, we have developed a simplified spectrophotometric pH sensor with accuracy and precision suitable for sea surface measurements with special emphasis on reduced size and cost. The reduced size will allow deployment of sensors on a much wider variety of platforms than are currently possible, and the reduced cost will make the instruments available to a broader research community. This prototype pH instrument was entered into the Wendy Schmidt Ocean Health X-Prize, an incentivized global competition to spur innovation in sensors to monitor ocean acidification's impact on marine ecosystems. Results from the three phases of competition which explored accuracy, precision, and stability culminating in a one month field trial are detailed. The prototype proved to be highly accurate (+/-0.009), with good precision (+/-0.004) and stability showing drift indistinguishable from that of the validation measurements. The innovations that enabled this sensor to succeed in the competition could allow for deployment of spectrophotometric sensors on new platforms such as NOAAs Global Drifter Program, a network of non-recovered surface drifting buoys, which would greatly extend the spatial and temporal resolution of ocean acidification measurements.

  20. Optical Observations of Psr J2021+3651 in the Dragonfly Nebula With the GTC

    Science.gov (United States)

    Kirichenko, Aida; Danilenko, Andrey; Shternin, Peter; Shibanov, Yuriy; Ryspaeva, Elizaveta; Zyuzin, Dima; Durant, Martin; Kargaltsev, Oleg; Pavlov, George; Cabrera-Lavers, Antonio

    2015-03-01

    PSR J2021+3651 is a 17 kyr old rotation powered pulsar detected in the radio, X-rays, and γ-rays. It powers a torus-like pulsar wind nebula with jets, dubbed the Dragonfly, which is very similar to that of the Vela pulsar. The Dragonfly is likely associated with the extended TeV source VER J2019+368 and extended radio emission. We conducted first deep optical observations with the Gran Telescopio Canarias in the Sloan r‧ band to search for optical counterparts of the pulsar and its nebula. No counterparts were detected down to r‧ ≳ 27.2 and ≳24.8 for the point-like pulsar and the compact X-ray nebula, respectively. We also reanalyzed Chandra archival X-ray data taking into account an interstellar extinction-distance relation, constructed by us for the Dragonfly line of sight using the red-clump stars as standard candles. This allowed us to constrain the distance to the pulsar, D=1.8-1.4+1.7 kpc at 90% confidence. It is much smaller than the dispersion measure distance of ˜12 kpc but compatible with a γ-ray “pseudo-distance” of 1 kpc. Based on that and the optical upper limits, we conclude that PSR J2021+3651, similar to the Vela pulsar, is a very inefficient nonthermal emitter in the optical and X-rays, while its γ-ray efficiency is consistent with an average efficiency for γ-pulsars of similar age. Our optical flux upper limit for the pulsar is consistent with the long-wavelength extrapolation of its X-ray spectrum while the nebula flux upper limit does not constrain the respective extrapolation. Based on observations made with the Gran Telescopio Canarias (GTC), instaled in the Spanish Observatorio del Roque de los Muchachos of the Instituto de Astrofsica de Canarias, in the island of La Palma, programme GTC3-11B.

  1. [Morphological observation on hypopus of Caloglyphus berlesei by optical microscope].

    Science.gov (United States)

    Zhan, Xiao-dong; Li, Chao-pin; Wu, Hua; Guo, Wei; Wang, Shao-shen

    2016-02-01

    To understand the structure characteristics of hypopus of Caloglyphus berlesei. The hypopus of C. berlesei was collected from the feed of Chinese Polyphaga, and was made into the conventional glass specimens. The structure characteristics of hypopus of C. berlesei were observed by an optical microscope. The hypopus of C. berlesei had 4 pairs of legs, and the foot claws and tarsus were well-developed. The structural features were shown, such as the setae of tibia and setae of genu. Genital plates were obviously ossified. The research on hypopus of Caloglyphus berlesei provides the reference for its further scientific classification and research on the life cycle.

  2. SPECTROPHOTOMETRIC METHOD FOR SIMULTANEOUS ESTIMATION OF TOLPERISONE HYDROCHLORIDE AND DICLOFENAC SODIUM IN SYNTHETIC MIXTURE

    OpenAIRE

    Patel Satish A; Hariyani Kaushik P

    2012-01-01

    The present manuscript describes simple, sensitive, rapid, accurate, precise and economical spectrophotometric method for the simultaneous determination of Diclofenac sodium and Tolperisone hydrochloride in bulk and synthetic mixture. The method is based on the simultaneous equations for analysis of both the drugs using methanol as solvent. Diclofenac sodium has absorbance maxima at 281 nm and Tolperisone hydrochloride has absorbance maxima at 255 nm in methanol. The linearity was obtained in...

  3. SPECTROPHOTOMETRIC METHOD FOR SIMULTANEOUS ESTIMATION OF EPERISONE HYDROCHLORIDE AND DICLOFENAC SODIUM IN SYNTHETIC MIXTURE

    OpenAIRE

    Patel Paresh U; Patel Sejal K; Patel Umang J

    2012-01-01

    The present manuscript describes simple, sensitive, rapid, accurate, precise and economical spectrophotometric method for the simultaneous determination of diclofenac sodium and Eperisone hydrochloride in bulk and synthetic mixture. The method is based on the simultaneous equations for analysis of both the drugs using methanol as solvent. Diclofenac sodium has absorbance maxima at 281 nm and Eperisone hydrochloride has absorbance maxima at 255 nm in methanol. The linearity was obtained in the...

  4. DLLME-spectrophotometric determination of glyphosate residue in legumes.

    Science.gov (United States)

    Çetin, Emine; Şahan, Serkan; Ülgen, Ahmet; Şahin, Uğur

    2017-09-01

    A new separation and pre-concentration method for spectrophotometric determination of glyphosate herbicide was developed. Glyphosate was converted into dithiocarbamic acid with CS 2 , followed by copper in the presence of ammonia to promote complex formation. This complex was collected in a CH 2 Cl 2 organic drop and absorbance measured at 435nm. The analytical parameters, such as the amount of NH 3 , Cu(II) and CS 2 , type of extraction solutions, and the ratio of dispersive and organic liquids were optimized. The calibration curve was linear in the range 0.5-10mgl -1 . The limits of detection and quantification were calculated from 3s to 10s criterions as 0.21mgl -1 and 0.70mgl -1 , respectively. The developed method was applied to legume samples with the satisfactory recovery values of 98±4-102±3%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Reconciling Optical and Radio Observations of the Binary Millisecond Pulsar PSR J1640+2224

    Science.gov (United States)

    Vigeland, Sarah J.; Deller, Adam T.; Kaplan, David L.; Istrate, Alina G.; Stappers, Benjamin W.; Tauris, Thomas M.

    2018-03-01

    Previous optical and radio observations of the binary millisecond pulsar PSR J1640+2224 have come to inconsistent conclusions about the identity of its companion, with some observations suggesting that the companion is a low-mass helium-core (He-core) white dwarf (WD), while others indicate that it is most likely a high-mass carbon–oxygen (CO) WD. Binary evolution models predict PSR J1640+2224 most likely formed in a low-mass X-ray binary based on the pulsar’s short spin period and long-period, low-eccentricity orbit, in which case its companion should be a He-core WD with mass about 0.35–0.39 M ⊙, depending on metallicity. If instead it is a CO WD, it would suggest that the system has an unusual formation history. In this paper we present the first astrometric parallax measurement for this system from observations made with the Very Long Baseline Array (VLBA), from which we determine the distance to be {1520}-150+170 {pc}. We use this distance and a reanalysis of archival optical observations originally taken in 1995 with the Wide Field Planetary Camera 2 on the Hubble Space Telescope (HST) to measure the WD’s mass. We also incorporate improvements in calibration, extinction model, and WD cooling models. We find that the existing observations are not sufficient to tightly constrain the companion mass, but we conclude the WD mass is >0.4 M ⊙ with >90% confidence. The limiting factor in our analysis is the low signal-to-noise ratio of the original HST observations.

  6. Quantization of buspirone hydrochloride in pure and pharmaceutical formulation by spectrophotometric method

    International Nuclear Information System (INIS)

    Kazi, A.A.; Mumtaz, A.; Sabri, M.U.

    2008-01-01

    A simple and sensitive method is described for the determination of bus pirone hydrochloride in bulk drug and in formulations employing spectrophotometric technique. The method is based on the interaction orbuspirone hydrochloride with ammonium molybdate in acidic media and the absorbance is measured at 700 nm. Beer's Law is obeyed in the range of 5 macro g to 350 micro g/ml and RSD is 0.96% for buspirone hydrochloride. Analytical data for the determination of pure compound is presented along with the application of the proposed method for the analysis of pharmaceutical formulation. (author)

  7. OPTICAL SPECTROSCOPIC OBSERVATIONS OF GAMMA-RAY BLAZAR CANDIDATES. V. TNG, KPNO, AND OAN OBSERVATIONS OF BLAZAR CANDIDATES OF UNCERTAIN TYPE IN THE NORTHERN HEMISPHERE

    Energy Technology Data Exchange (ETDEWEB)

    Álvarez Crespo, N.; Massaro, F. [Dipartimento di Fisica, Università degli Studi di Torino, via Pietro Giuria 1, I-10125 Torino (Italy); Masetti, N. [INAF—Istituto di Astrofisica Spaziale e Fisica Cosmica di Bologna, via Gobetti 101, I-40129, Bologna (Italy); Ricci, F.; La Franca, F. [Dipartimento di Matematica e Fisica, Università Roma Tre, via della Vasca Navale 84, I-00146, Roma (Italy); Landoni, M. [INAF-Osservatorio Astronomico di Brera, Via Emilio Bianchi 46, I-23807 Merate (Italy); Patiño-Álvarez, V.; Chavushyan, V.; Torrealba, J. [Instituto Nacional de Astrofisica, Óptica y Electrónica, Apartado Postal 51-216, 72000 Puebla, México (Mexico); D’Abrusco, R.; Paggi, A.; Smith, Howard A. [Harvard—Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, MA 02138 (United States); Jiménez-Bailón, E. [Instituto de Astronomía, Universidad Nacional Autónoma de México, Apdo. Postal 877, Ensenada, 22800 Baja California, México (Mexico); Latronico, L. [Istituto Nazionale di Fisica Nucleare, Sezione di Torino, I-10125 Torino (Italy); Tosti, G. [Dipartimento di Fisica, Università degli Studi di Perugia, I-06123 Perugia (Italy)

    2016-02-15

    The extragalactic γ-ray sky is dominated by emission from blazars, a peculiar class of active galactic nuclei. Many of the γ-ray sources included in the Fermi-Large Area Telescope Third Source catalog (3FGL) are classified as blazar candidates of uncertain type (BCUs) because there are no optical spectra available in the literature to confirm their nature. In 2013, we started a spectroscopic campaign to look for the optical counterparts of the BCUs and of the unidentified γ-ray sources to confirm their blazar nature. Whenever possible we also determine their redshifts. Here, we present the results of the observations carried out in the northern hemisphere in 2013 and 2014 at the Telescopio Nazionale Galileo, Kitt Peak National Observatory, and Observatorio Astronómico Nacional in San Pedro Mártir. In this paper, we describe the optical spectra of 25 sources. We confirmed that all of the 15 BCUs observed in our campaign and included in our sample are blazars and we estimated the redshifts for three of them. In addition, we present the spectra for three sources classified as BL Lacs in the literature but with no optical spectra available to date. We found that one of them is a quasar (QSO) at a redshift of z = 0.208 and the other two are BL Lacs. Moreover, we also present seven new spectra for known blazars listed in the Roma-BZCAT that have an uncertain redshift or are classified as BL Lac candidates. We found that one of them, 5BZB J0724+2621, is a “changing look” blazar. According to the spectrum available in the literature, it was classified as a BL Lac, but in our observation we clearly detected a broad emission line that led us to classify this source as a QSO at z = 1.17.

  8. Spectrophotometric determination of nitrite by its catalytic effect on the oxidation of congo red with bromate

    Directory of Open Access Journals (Sweden)

    Zenovia Moldovan

    2012-08-01

    Full Text Available A novel simple, sensitive and rapid kinetic-spectrophotometric method for the determination of trace amounts of nitrite is proposed. The method is based on its catalytic effect on the oxidation of congo red (CR by potassium bromate in acidic solution. The oxidation reaction is monitored spectrophotometrically by measuring the decrease in the absorbance of CR at a suitable λmax = 570 nm for the first 10–40 s from the start of the reaction. Under the optimum experimental conditions (sulfuric acid, 0.3 M; CR, 0.75Χ10-4 M; potassium bromate, 5Χ10-4 M and 25 oC, nitrite can be determined in the range of 0.015–0.75 µg mL−1 with the detection limit of 0.006 µg mL−1. The relative standard deviation of five replicate determination of 0.25 µg mL−1 nitrite was 2.5%. The proposed method was applied satisfactorily to the determination of nitrite in spiked drinking water samples.DOI: http://dx.doi.org/10.4314/bcse.v26i2.1

  9. Validation of HPLC and UV spectrophotometric methods for the determination of meropenem in pharmaceutical dosage form.

    Science.gov (United States)

    Mendez, Andreas S L; Steppe, Martin; Schapoval, Elfrides E S

    2003-12-04

    A high-performance liquid chromatographic method and a UV spectrophotometric method for the quantitative determination of meropenem, a highly active carbapenem antibiotic, in powder for injection were developed in present work. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by reversed-phase technique on an RP-18 column with a mobile phase composed of 30 mM monobasic phosphate buffer and acetonitrile (90:10; v/v), adjusted to pH 3.0 with orthophosphoric acid. The UV spectrophotometric method was performed at 298 nm. The samples were prepared in water and the stability of meropenem in aqueous solution at 4 and 25 degrees C was studied. The results were satisfactory with good stability after 24 h at 4 degrees C. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the two methods. The proposed methods are highly sensitive, precise and accurate and can be used for the reliable quantitation of meropenem in pharmaceutical dosage form.

  10. A COMPARISON OF A SPECTROPHOTOMETRIC (QUERCETIN) METHOD AND AN ATOMIC-ABSORPTION METHOD FOR DETERMINATION OF TIN IN FOOD

    DEFF Research Database (Denmark)

    Engberg, Å

    1973-01-01

    Procedures for the determination of tin in food, which involve a spectrophotometric method (with the quercetin-tin complex) and an atomic-absorption method, are described. The precision of the complete methods and of the individual analytical steps required is evaluated, and the parameters...

  11. Development of high-speed and wide-angle visible observation diagnostics on Experimental Advanced Superconducting Tokamak using catadioptric optics

    International Nuclear Information System (INIS)

    Yang, J. H.; Hu, L. Q.; Zang, Q.; Han, X. F.; Shao, C. Q.; Sun, T. F.; Chen, H.; Wang, T. F.; Li, F. J.; Hu, A. L.; Yang, X. F.

    2013-01-01

    A new wide-angle endoscope for visible light observation on the Experimental Advanced Superconducting Tokamak (EAST) has been recently developed. The head section of the optical system is based on a mirror reflection design that is similar to the International Thermonuclear Experimental Reactor-like wide-angle observation diagnostic on the Joint European Torus. However, the optical system design has been simplified and improved. As a result, the global transmittance of the system is as high as 79.6% in the wavelength range from 380 to 780 nm, and the spatial resolution is <5 mm for the full depth of field (4000 mm). The optical system also has a large relative aperture (1:2.4) and can be applied in high-speed camera diagnostics. As an important diagnostic tool, the optical system has been installed on the HT-7 (Hefei Tokamak-7) for its final experimental campaign, and the experiments confirmed that it can be applied to the investigation of transient processes in plasma, such as ELMy eruptions in H-mode, on EAST

  12. Acidity Constants Determination of Triazine Dye Derivative in the presence of some Surfactants by Multiwavelength Spectrophotometric and Spectrofluorimetric

    Directory of Open Access Journals (Sweden)

    Ali Yeganeh Faal

    2014-03-01

    Full Text Available In this work, acidity constants protonated form of 4.4'-bis astilbene-2,2'-disulfonic-disodium salts (TRIAZ have been determined spectrophotometrically and spectrofluorimetrically at 25◦C and ionic strength of 0.1M KNO3. A program based on MCR-ALS applied for determination of acidity constants. The results show that the peak values of dye are influenced by the presence of anionic, cationic, and nonionic surfactants. The effects of sodium dodecyl sulfate (SDS, Triton X-100 (TX-100 and cetyl trimethyl ammonium bromide (CTAB as a surface-active agent on the acidic and basic forms, and the spectral properties of dye were studied. Also, we determined the critical micelle concentration (CMC for these surfactants by spectrophotometric and spectrofluorimetric triazine dye probes. In addition, by using of evolving factor analysis (EFA and multivariate curve resolution alternative least squares (MCR-ALS methods, acidity constants were acquired.

  13. Validated univariate and multivariate spectrophotometric methods for the determination of pharmaceuticals mixture in complex wastewater

    Science.gov (United States)

    Riad, Safaa M.; Salem, Hesham; Elbalkiny, Heba T.; Khattab, Fatma I.

    2015-04-01

    Five, accurate, precise, and sensitive univariate and multivariate spectrophotometric methods were developed for the simultaneous determination of a ternary mixture containing Trimethoprim (TMP), Sulphamethoxazole (SMZ) and Oxytetracycline (OTC) in waste water samples collected from different cites either production wastewater or livestock wastewater after their solid phase extraction using OASIS HLB cartridges. In univariate methods OTC was determined at its λmax 355.7 nm (0D), while (TMP) and (SMZ) were determined by three different univariate methods. Method (A) is based on successive spectrophotometric resolution technique (SSRT). The technique starts with the ratio subtraction method followed by ratio difference method for determination of TMP and SMZ. Method (B) is successive derivative ratio technique (SDR). Method (C) is mean centering of the ratio spectra (MCR). The developed multivariate methods are principle component regression (PCR) and partial least squares (PLS). The specificity of the developed methods is investigated by analyzing laboratory prepared mixtures containing different ratios of the three drugs. The obtained results are statistically compared with those obtained by the official methods, showing no significant difference with respect to accuracy and precision at p = 0.05.

  14. A QUASAR CATALOG WITH SIMULTANEOUS UV, OPTICAL, AND X-RAY OBSERVATIONS BY SWIFT

    Energy Technology Data Exchange (ETDEWEB)

    Wu Jian; Grupe, Dirk; Koch, Scott; Gelbord, Jonathan; Schneider, Donald P.; Gronwall, Caryl; Porterfield, Blair L. [Department of Astronomy and Astrophysics, Pennsylvania State University, 525 Davey Lab, University Park, PA 16802 (United States); Vanden Berk, Daniel; Wesolowski, Sarah, E-mail: jwu@astro.psu.edu [Department of Physics, Saint Vincent College, 300 Fraser Purchase Road, Latrobe, PA 15650 (United States)

    2012-08-01

    We have compiled a catalog of optically selected quasars with simultaneous observations in UV/optical and X-ray bands by the Swift Gamma-ray Burst Explorer. Objects in this catalog are identified by matching the Swift pointings with the Sloan Digital Sky Survey Data Release 5 quasar catalog. The final catalog contains 843 objects, among which 637 have both Ultraviolet Optical Telescope (UVOT) and X-Ray Telescope (XRT) observations and 354 of which are detected by both instruments. The overall X-ray detection rate is {approx}60% which rises to {approx}85% among sources with at least 10 ks of XRT exposure time. We construct the time-averaged spectral energy distribution (SED) for each of the 354 quasars using UVOT photometric measurements and XRT spectra. From model fits to these SEDs, we find that the big blue bump contributes about {approx}0.3 dex to the quasar luminosity. We re-visit the {alpha}{sub ox}-L{sub 2500A} relation by selecting a clean sample with only Type 1 radio-quiet quasars; the dispersion of this relation is reduced by at least 15% compared with studies that use non-simultaneous UV/optical and X-ray data. We only found a weak correlation between L{sub bol}/L{sub Edd} and {alpha}{sub UV}. We do not find significant correlations between {alpha}{sub x} and {alpha}{sub ox}, {alpha}{sub ox} and {alpha}{sub UV}, and {alpha}{sub x} and log L(0.3-10 keV). The correlations between {alpha}{sub UV} and {alpha}{sub x}, {alpha}{sub ox} and {alpha}{sub x}, {alpha}{sub ox} and {alpha}{sub UV}, L{sub bol}/L{sub Edd} and {alpha}{sub x}, and L{sub bol}/L{sub Edd} and {alpha}{sub ox} are stronger among low-redshift quasars, indicating that these correlations are likely driven by the changes of SED shape with accretion state.

  15. Sensitive flow-injection spectrophotometric analysis of bromopride

    Science.gov (United States)

    Lima, Liliane Spazzapam; Weinert, Patrícia Los; Pezza, Leonardo; Pezza, Helena Redigolo

    2014-12-01

    A flow injection spectrophotometric procedure employing merging zones is proposed for direct bromopride determination in pharmaceutical formulations and biological fluids. The proposed method is based on the reaction between bromopride and p-dimethylaminocinnamaldehyde (p-DAC) in acid medium, in the presence of sodium dodecyl sulfate (SDS), resulting in formation of a violet product (λmax = 565 nm). Experimental design methodologies were used to optimize the experimental conditions. The Beer-Lambert law was obeyed in a bromopride concentration range of 3.63 × 10-7 to 2.90 × 10-5 mol L-1, with a correlation coefficient (r) of 0.9999. The limits of detection and quantification were 1.07 × 10-7 and 3.57 × 10-7 mol L-1, respectively. The proposed method was successfully applied to the determination of bromopride in pharmaceuticals and human urine, and recoveries of the drug from these media were in the ranges 99.6-101.2% and 98.6-102.1%, respectively. This new flow injection procedure does not require any sample pretreatment steps.

  16. Sensitive inexpensive spectrophotometric and spectrofluorimetric analysis of ezogabine, levetiracetam and topiramate in tablet formulations using Hantzsch condensation reaction

    Science.gov (United States)

    Ibrahim, F. A.; El-Yazbi, A. F.; Wagih, M. M.; Barary, M. A.

    2017-09-01

    Two highly sensitive, simple and selective spectrophotometric and spectrofluorimetric assays have been investigated for the analysis of ezogabine, levetiracetam and topiramate in their pure and in pharmaceutical dosage forms. The suggested methods depend on the condensation of the primary amino-groups in the three drugs with acetylacetone and formaldehyde according to Hantzsch reaction yielding highly fluorescent yellow colored dihydropyridine derivatives. The reaction products of ezogabine, levetiracetam and topiramate were measured spectrophotometrically at 418, 390 and 380 nm or spectrofluorimetrically at λem/ex of 495/425 nm, 490/415 nm and 488/410 nm, respectively. Various experimental conditions have been carefully studied to maximize the reaction yield. At the optimum reaction conditions, the calibration curves were rectilinear over the concentration ranges of 8-25, 60-180 and 80-200 μg/mL spectrophotometrically and 0.02-0.2, 0.2-1.2 and 0.2-1.5 μg/mL spectrofluorimetrically for ezogabine, levetiracetam and topiramate, respectively with good correlation coefficients. The suggested methods were applied successfully for the analysis of ezogabine, levetiracetam and topiramate in their commercial tablets with high percentage recoveries and negligible interference from various excipients in pharmaceutical dosage forms. The results were statistically analyzed and showed the absence of any significant difference between both developed and published methods. The procedures were validated and evaluated by the ICH guidelines revealing good reproducibility and accuracy. Therefore, the two proposed methods may be considered of high interest for practical and reliable analysis of ezogabine, levetiracetam and topiramate in pharmaceutical dosage forms.

  17. Spectrophotometric study of the complexation reaction between niobium(V) and 5-sulpho-3-nitro-salicylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, D S; Shivahare, G C [Rajasthan Univ., Jaipur (India). Dept. of Chemistry

    1975-04-01

    5-sulpho-3 nitro-salicylic acid forms a yellow complex with niobium(V) at pH 8.5 and the reaction has been successfully studied spectrophotometrically. The results of the Job's continuous variation method and the molar ratio method indicate a composition of 1:2 for the complex. Stability constant of the complex has also been determined. (auth)

  18. Adaptive Optics Observations of Exoplanets, Brown Dwarfs, and Binary Stars

    Science.gov (United States)

    Hinkley, Sasha

    2012-04-01

    The current direct observations of brown dwarfs and exoplanets have been obtained using instruments not specifically designed for overcoming the large contrast ratio between the host star and any wide-separation faint companions. However, we are about to witness the birth of several new dedicated observing platforms specifically geared towards high contrast imaging of these objects. The Gemini Planet Imager, VLT-SPHERE, Subaru HiCIAO, and Project 1640 at the Palomar 5m telescope will return images of numerous exoplanets and brown dwarfs over hundreds of observing nights in the next five years. Along with diffraction-limited coronagraphs and high-order adaptive optics, these instruments also will return spectral and polarimetric information on any discovered targets, giving clues to their atmospheric compositions and characteristics. Such spectral characterization will be key to forming a detailed theory of comparative exoplanetary science which will be widely applicable to both exoplanets and brown dwarfs. Further, the prevalence of aperture masking interferometry in the field of high contrast imaging is also allowing observers to sense massive, young planets at solar system scales (~3-30 AU)- separations out of reach to conventional direct imaging techniques. Such observations can provide snapshots at the earliest phases of planet formation-information essential for constraining formation mechanisms as well as evolutionary models of planetary mass companions. As a demonstration of the power of this technique, I briefly review recent aperture masking observations of the HR 8799 system. Moreover, all of the aforementioned techniques are already extremely adept at detecting low-mass stellar companions to their target stars, and I present some recent highlights.

  19. Thin film optical coatings for the ultraviolet spectral region

    Science.gov (United States)

    Torchio, P.; Albrand, G.; Alvisi, M.; Amra, C.; Rauf, H.; Cousin, B.; Otrio, G.

    2017-11-01

    The applications and innovations related to the ultraviolet field are today in strong growth. To satisfy these developments which go from biomedical to the large equipment like the Storage Ring Free Electron Laser, it is crucial to control with an extreme precision the optical performances, in using the substrates and the thin film materials impossible to circumvent in this spectral range. In particular, the reduction of the losses by electromagnetic diffusion, Joule effect absorption, or the behavior under UV luminous flows of power, resistance to surrounding particulate flows... become top priority which concerns a broad European and international community. Our laboratory has the theoretical, experimental and technological tools to design and fabricate numerous multilayer coatings with desirable optical properties in the visible and infrared spectral ranges. We have extended our expertise to the ultraviolet. We present here some results on high reflectivity multidielectric mirrors towards 250 nm in wavelength, produced by Ion Plating Deposition. The latter technique allows us to obtain surface treatments with low absorption and high resistance. We give in this study the UV transparent materials and the manufacturing technology which have been the best suited to meet requirements. Single UV layers were deposited and characterized. HfO2/SiO2 mirrors with a reflectance higher than 99% at 300 nm were obtained. Optical and non-optical characterizations such as UV spectrophotometric measurements, X-Ray Diffraction spectra, Scanning Electron Microscope and Atomic Force Microscope images were performed

  20. Spectrophotometric and spectrofluorometric determination of uranium using a flotation process with benzoate and rivanol

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Herroz, C.; Hernandez, M.; Sanchez-Pedreno, C.

    1988-01-01

    Tribenzouranyl anion forms with rivnol an ion-association compound which is floated with isopropyl ether and dissolved in ethanol. As a consequence, new spectrophotometric and spectrofluorimetric methods for the determination of trace amounts of uranium are developed. At 373 nm Beer's law is obeyed over the range 10-150 /mu/g of uranium. When the spectrofluorimetric technique is used, calibration graph is linear in the 2-25 /mu/g range.

  1. Influence of γ-irradiation on the optical properties of nanocrystalline tin phthalocyanine thin films

    International Nuclear Information System (INIS)

    El-Nahass, M.M.; Atta, A.A.; El-Shazly, E.A.A.; Faidah, A.S.; Hendi, A.A.

    2009-01-01

    SnPc in powder and thin film forms were found to be polycrystalline with monoclinic lattice. The morphological and structural properties of the obtained SnPc films were characterized from electron scanning micrographs and X-ray diffraction patterns. In the γ-irradiated film the formed agglomeration increased the crystallite size. The refractive index, n, and the absorption index, k, were obtained from spectrophotometric measurements of the transmittance and reflectance at normal incidence of light in the wavelength range 200-2500 nm. γ-Irradiation films shifted the transmission edge toward lower wavelength and increase the optical energy gap value. According to the analysis of dispersion curves, the dielectric constants and dispersion parameters were obtained. The absorption analysis performed indicated indirect allowed electronic transitions and the optical energy band gap 2.84 and 2.63 eV for the as-deposited and the γ-irradiated films, respectively.

  2. Spectrophotometric and spectrofluorimetric methods for determination of certain biologically active phenolic drugs in their bulk powders and different pharmaceutical formulations

    Science.gov (United States)

    Omar, Mahmoud A.; Badr El-Din, Kalid M.; Salem, Hesham; Abdelmageed, Osama H.

    2018-03-01

    Two simple and sensitive spectrophotometric and spectrofluorimetric methods for the determination of terbutaline sulfate, fenoterol hydrobromide, etilefrine hydrochloride, isoxsuprine hydrochloride, ethamsylate, doxycycline hyclate have been developed. Both methods were based on the oxidation of the cited drugs with cerium (IV) in acid medium. The spectrophotometric method was based on measurement of the absorbance difference (ΔA), which represents the excess cerium (IV), at 317 nm for each drug. On the other hand, the spectrofluorimetric method was based on measurement of the fluorescent of the produced cerium (III) at emission wavelength 354 nm (λexcitation = 255 nm) for the concentrations studied for each drug. For both methods, the variables affecting the reactions were carefully investigated and the conditions were optimized. Linear relationships were found between either ΔA or the fluorescent of the produced cerium (III) values and the concentration of the studied drugs in a general concentration range of 2.0-24.0 μg mL- 1, 20.0-24.0 ng mL- 1 with good correlation coefficients in the following range 0.9990-0.9999, 0.9990-0.9993 for spectrophotometric and spectrofluorimetric methods respectively. The limits of detection and quantitation of spectrophotometric method were found in general concentration range 0.190-0.787 and 0.634-2.624 μg mL- 1respectively. For spectrofluorimetric method, the limits of detection and quantitation were found in general concentration range 4.77-9.52 and 15.91-31.74 ng mL- 1 respectively. The stoichiometry of the reaction was determined, and the reactions pathways were postulated. The analytical performance of the methods, in terms of accuracy and precision, were statistically validated and the results obtained were satisfactory. The methods have been successfully applied to the determination of the cited drugs in their commercial pharmaceutical formulations. Statistical comparison of the results with the reference methods

  3. Spectro-photometric study of the GRB 030329 host galaxy

    International Nuclear Information System (INIS)

    Gorosabel, J.; Ramirez, D. Perez

    2005-01-01

    In this study we present optical/near-infrared (NIR) broad band photometry and optical spectroscopic observations of the GRB 030329 host galaxy. The Spectral Energy Distribution (SED) of the host is consistent with a starburst galaxy template with a dominant stellar population age of ∼ 150 Myr and an extinction A ν ∼ 0.6. Analysis of the spectral emission lines shows that the host is likely a low metallicity galaxy. Two independent diagnostics, based on the restframe UV continuum and the [OII] line flux, provide a consistent unextincted star formation rate of SFRN ∼ 0.6 Myr -1 . The low absolute magnitude of the host (M B ∼ -16.5) implies a high specific star formation rate value, SSFR ≅ 34 Myr -1 (L/L) -1

  4. Multiwavelength Observations of the 2002 Outburst of GX 339-4: Two Patterns of X-Ray-Optical/Near-Infrared Behavior

    Science.gov (United States)

    Homan, Jeroen; Buxton, Michelle; Markoff, Sera; Bailyn, Charles D.; Nespoli, Elisa; Belloni, Tomaso

    2005-05-01

    We report on quasi-simultaneous Rossi X-Ray Timing Explorer and optical/near-infrared (NIR) observations of the black hole candidate X-ray transient GX 339-4. Our observations were made over a time span of more than 8 months in 2002 and cover the initial rise and transition from a hard to a soft spectral state in X-rays. Two distinct patterns of correlated X-ray-optical/NIR behavior were found. During the hard state, the optical/NIR and X-ray fluxes correlated well, with a NIR versus X-ray flux power-law slope similar to that of the correlation found between X-ray and radio fluxes in previous studies of GX 339-4 and other black hole binaries. As the source went through an intermediate state, the optical/NIR fluxes decreased rapidly, and once it had entered the spectrally soft state, the optical/NIR spectrum of GX 339-4 was much bluer, and the ratio of X-ray to NIR flux was higher by a factor of more than 10 compared to the hard state. In the spectrally soft state, changes in the NIR preceded those in the soft X-rays by more than 2 weeks, indicating a disk origin of the NIR emission and providing a measure of the viscous timescale. A sudden onset of NIR flaring of ~0.5 mag on a timescale of 1 day was also observed during this period. We present spectral energy distributions, including radio data, and discuss possible sources for the optical/NIR emission. We conclude that, in the hard state, this emission probably originates in the optically thin part of a jet and that in none of the X-ray states is X-ray reprocessing the dominant source of optical/NIR emission. Finally, comparing the light curves from the all-sky monitor (ASM) and Proportional Counter Array (PCA) instruments, we find that the X-ray/NIR delay depends critically on the sensitivity of the X-ray detector, with the delay inferred from the PCA (if present at all) being a factor of 3-6 times shorter than the delay inferred from the ASM; this may be important in interpreting previously reported X-ray-optical

  5. Experimental observation of the optical spin-orbit torque

    Czech Academy of Sciences Publication Activity Database

    Tesařová, N.; Němec, P.; Rozkotová, E.; Zemen, Jan; Janda, T.; Butkovičová, D.; Trojánek, F.; Olejník, Kamil; Novák, Vít; Malý, P.; Jungwirth, Tomáš

    2013-01-01

    Roč. 7, Jun (2013), s. 493-499 ISSN 1749-4885 R&D Projects: GA MŠk(CZ) LM2011026; GA ČR GD202/09/H041 EU Projects: European Commission(XE) 268066 - 0MSPIN; European Commission(XE) 215368 - SemiSpinNet Grant - others:AV ČR(CZ) AP0801 Program:Akademická prémie - Praemium Academiae Keywords : ferromagnetic semiconductor * magneto-optical spectroscopy Subject RIV: BH - Optics, Masers, Lasers Impact factor: 29.958, year: 2013

  6. MEOS Microsatellite Earth Observation using Miniature Integrated-Optic IR Spectrometers

    Science.gov (United States)

    Kruzelecky, Roman

    future, the MEOS Miniature Earth Observing Satellite will innovatively combine remote atmospheric/land-cover measurements with ecosystem modelling in near real-time to obtain simultaneous variations in lower tropospheric GHG mixing ratios and the resulting responses of surface ecosystems. MEOS will provide lower tropospheric CO2 , CH4 , CO, N2 O, H2 O and aerosol mixing ratios over natural sources and sinks using two kinds of synergistic observations; a forward limb measurement and a follow-on nadir measurement over the same geographical tangent point. The measurements will be accomplished using separate limb and nadir suites of miniature lineimaging spectrometers and will be spatially coordinated such that the same air mass is observed in both views within a few minutes. The limb data will consist of 16-pixel vertical spectral line imaging to provide 2.5-km vertical resolution, while the corresponding nadir measurements will view sixteen 5 by 10 km2 ground pixels with a 160-km East-West swath width. The separate limb and nadir instrument suites each feature two complementary NIR miniature spectrometers that will operate in parallel, alternating the collected optical signal between the high-resolution Fabry-Perot guided-wave FP-IOSPEC spectrometer with simultaneous multiple microchannels at 0.03 FWHM with SNR>400 and the 1220 to 2450 nm broad-band spectrometer with 1.2 nm FWHM such that one undergoes the illuminated segment of the processing while the other spectrometer undergoes its dark signal processing. This spectral region provides several harmonic optical absorption bands associated with CO2 , CH4 , CO, H2 O and N2 O. The innovative data synergy of the coarse resolution broad-band spectra with the scanned spectral measurements of the trace-gas fine features at 0.03 nm FWHM in multiple microchannels will be used to improve the accuracy of the trace gas retrievals relative to current missions. In addition, the mission will retrieve cloud top pressures to better than

  7. Optical Orbit Determination of a Geosynchronous Earth Orbit Satellite Effected by Baseline Distances between Various Ground-based Tracking Stations Ⅱ: COMS Case with Analysis of Actual Observation Data

    Directory of Open Access Journals (Sweden)

    Ju Young Son

    2015-09-01

    Full Text Available We estimated the orbit of the Communication, Ocean and Meteorological Satellite (COMS, a Geostationary Earth Orbit (GEO satellite, through data from actual optical observations using telescopes at the Sobaeksan Optical Astronomy Observatory (SOAO of the Korea Astronomy and Space Science Institute (KASI, Optical Wide field Patrol (OWL at KASI, and the Chungbuk National University Observatory (CNUO from August 1, 2014, to January 13, 2015. The astrometric data of the satellite were extracted from the World Coordinate System (WCS in the obtained images, and geometrically distorted errors were corrected. To handle the optically observed data, corrections were made for the observation time, light-travel time delay, shutter speed delay, and aberration. For final product, the sequential filter within the Orbit Determination Tool Kit (ODTK was used for orbit estimation based on the results of optical observation. In addition, a comparative analysis was conducted between the precise orbit from the ephemeris of the COMS maintained by the satellite operator and the results of orbit estimation using optical observation. The orbits estimated in simulation agree with those estimated with actual optical observation data. The error in the results using optical observation data decreased with increasing number of observatories. Our results are useful for optimizing observation data for orbit estimation.

  8. Spectrophotometric Determination of Gemifloxacin Mesylate in Pharmaceutical Formulations Through Ion-Pair Complex Formation

    Directory of Open Access Journals (Sweden)

    Marothu Vamsi Krishna

    2008-01-01

    Full Text Available Four simple and sensitive ion-pairing spectrophotometric methods have been described for the assay of gemifloxacin mesylate (GFX either in pure form or in pharmaceutical formulations. The developed methods involve formation of colored chloroform extractable ion-pair complexes of the drug with safranin O (SFN O and methylene blue (MB in basic medium; Napthol blue 12BR (NB 12BR and azocaramine G (AG in acidic medium. The extracted complexes showed absorbance maxima at 525, 650, 620 and 540 nm for SFN O, MB, NB 12BR and AG, respectively.Beer's law is obeyed in the concentration ranges 3-15, 4-20, 2-10 and 2-10 μg/mL with molar absorptivity of 2.81 × 104, 2.20 x 104, 4.02 × 104 and 4.15 × 104 L mole−1 cm−1 and relative standard deviation of 0.077, 0.104, 0.080 and 0.103% for SFN O, MB, NB 12BR and AG, respectively. These methods have been successfully applied for the assay of drug in pharmaceutical formulations. No interference was observed from common pharmaceutical adjuvants. Results of analysis were validated statistically and through recovery studies.

  9. The optical, infrared and radio properties of extragalactic sources observed by SDSS, 2mass and first surveys

    International Nuclear Information System (INIS)

    Z. Ivezic et al.

    2002-01-01

    We positionally match sources observed by the Sloan Digital Sky Survey (SDSS), the Two Micron All Sky Survey (2MASS), and the Faint Images of the Radio Sky at Twenty-cm (FIRST) survey. Practically all 2MASS sources are matched to an SDSS source within 2 arcsec; ∼ 11% of them are optically resolved galaxies and the rest are dominated by stars. About 1/3 of FIRST sources are matched to an SDSS source within 2 arcsec; ∼ 80% of these are galaxies and the rest are dominated by quasars. Based on these results, we project that by the completion of these surveys the matched samples will include about 10 7 and 10 6 galaxies observed by both SDSS and 2MASS, and about 250,000 galaxies and 50,000 quasars observed by both SDSS and FIRST. Here we present a preliminary analysis of the optical, infrared and radio properties for the extragalactic sources from the matched samples. In particular, we find that the fraction of quasars with stellar colors missed by the SDSS spectroscopic survey is probably not larger than ∼ 10%, and that the optical colors of radio-loud quasars are ∼ 0.05 mag. redder (with 4σ significance) than the colors of radio-quiet quasars

  10. Spectrophotometric Examination of Rough Print Surfaces

    Directory of Open Access Journals (Sweden)

    Erzsébet Novotny

    2011-05-01

    Full Text Available The objective was to assess the impact of the surface texture of individual creative paper types (coated or patternedon the quality of printing and to identify to what extent the various creative paper types require specific types ofspectrophotometers. We used stereomicroscopic images to illustrate unprinted and printed surfaces of creative papertypes. Surface roughness was measured to obtain data on the unevenness of surfaces. Spectrophotometric tests wereused to select the most suitable spectrophotometer from meters with different illumination setup for testing anygiven print. For the purpose of testing, we used spectrophotometers which are commonly available generally used totest print products for colour accuracy. With the improvement of measuring geometries, illumination setup, colourmeasurement becomes more and more capable of producing reliable results unaffected by surface textures. Our testshave proved this fact by showing that the GretagMacbeth Spectrolino with annular illumination is less sensitive tosurface texture than the X-Rite Spetrodensitometer and the Techkon SpetroDens with directional illumination. Furthertests have brought us to the conclusion that there is a difference even between the two devices with directionalillumination. While the X-Rite 530 Spectrodensitometer is more suitable for testing coated surfaces, the TechkonSpectroDens can come close to ΔE*ab values produced by the annular illuminated device for textured surfaces.

  11. Rapid and direct spectrophotometric method for kinetics studies and routine assay of peroxidase based on aniline diazo substrates.

    Science.gov (United States)

    Mirazizi, Fatemeh; Bahrami, Azita; Haghbeen, Kamahldin; Shahbani Zahiri, Hossein; Bakavoli, Mehdi; Legge, Raymond L

    2016-12-01

    Peroxidases are ubiquitous enzymes that play an important role in living organisms. Current spectrophotometrically based peroxidase assay methods are based on the production of chromophoric substances at the end of the enzymatic reaction. The ambiguity regarding the formation and identity of the final chromophoric product and its possible reactions with other molecules have raised concerns about the accuracy of these methods. This can be of serious concern in inhibition studies. A novel spectrophotometric assay for peroxidase, based on direct measurement of a soluble aniline diazo substrate, is introduced. In addition to the routine assays, this method can be used in comprehensive kinetics studies. 4-[(4-Sulfophenyl)azo]aniline (λmax = 390 nm, ɛ = 32 880 M(-1) cm(-1) at pH 4.5 to 9) was introduced for routine assay of peroxidase. This compound is commercially available and is indexed as a food dye. Using this method, a detection limit of 0.05 nmol mL(-1) was achieved for peroxidase.

  12. Sensitive spectrophotometric determination of ascorbic acid in drugs and foods using surface plasmon resonance band of silver nanoparticles

    Directory of Open Access Journals (Sweden)

    Kobra Zarei

    2015-12-01

    Full Text Available A simple and sensitive procedure was proposed for spectrophotometric determination of ascorbic acid. It was found that the reduction of Ag+ to silver nanoparticles (Ag-NPs by ascorbic acid in the presence of polyvinylpyrrolidone (PVP as a stabilizing agent produce very intense surface plasmon resonance peak of Ag-NPs. The plasmon absorbance of the Ag-NPs at λ = 440 nm allows the quantitative spectrophotometric detection of the ascorbic acid. The calibration curve was linear with concentration of ascorbic acid in the range of 0.5–60 μM. The detection limit was obtained as 0.08 μM. The influence of potential interfering substances on the determination of ascorbic acid was studied. The proposed method was successfully applied for the determination of ascorbic acid in some powdered drink mixtures, commercial orange juice, natural orange juice, vitamin C injection, effervescent tablet, and multivitamin tablet.

  13. Preparing the optics technology to observe the hot universe

    DEFF Research Database (Denmark)

    Bavdaz, M.; Wille, Eric; Wallace, Kotska

    2014-01-01

    is the Silicon Pore Optics (SPO) [1 to 23], a modular X-ray optics technology, which utilises processes and equipment developed for the semiconductor industry. The paper provides an overview of the programmatic background, the status of SPO technology and gives an outline of the development roadmap...

  14. Spectrophotometric analysis of flavonoid-DNA binding interactions at physiological conditions

    Science.gov (United States)

    Janjua, Naveed Kausar; Siddiqa, Asima; Yaqub, Azra; Sabahat, Sana; Qureshi, Rumana; Haque, Sayed ul

    2009-12-01

    Mode of interactions of three flavonoids [morin (M), quercetin (Q), and rutin (R)] with chicken blood ds.DNA (ck.DNA) has been investigated spectrophotometrically at different temperatures including body temperature (310 K) and at two physiological pH values, i.e. 7.4 (human blood pH) and 4.7 (stomach pH). The binding constants, Kf, evaluated using Benesi-Hildebrand equation showed that the flavonoids bind effectively through intercalation at both pH values and body temperature. Quercetin, somehow, showed greater binding capabilities with DNA. The free energies of flavonoid-DNA complexes indicated the spontaneity of their binding. The order of binding constants of three flavonoids at both pH values were found to be Kf(Q) > Kf(R) > Kf(M) and at 310 K.

  15. Spectrophotometric determination of La (III) with sulphamethoxazole based hydroxy triazene

    International Nuclear Information System (INIS)

    Manwani, Sapana; Chauhan, R.S.; Goswami, A.K.

    2015-01-01

    In the present study, 3-hydroxy-3-p-chlorophenyll-1-(4-amino-N-(5-methyl-1,2-oxazole-3- yl) benzenesulphonamide-methane) triazene has been synthesized by coupling of hydroxylamine obtained by reduction of nitro compound with diazonium salt obtained from sulphamethoxazole taking hydroxylamine in excess at temperature between 0-5°C. Chemical structure of the synthesized compound was confirmed by IR, 1 H NMR, MASS and by elemental analysis. The complex of the reagent with La (III) has been studied. 3-hydroxy-3-p-chlorophenyll-1-(4-amino-N-(5-methyl-1,2-oxazole-3-yl) benzenesulphonamide-methane) triazene has been used for spectrophotometric determination of lanthanum (III) at 392 nm, keeping the pH between 8.5 to 8.9

  16. Infrared and optical observations of Nova Mus 1983

    International Nuclear Information System (INIS)

    Whitelock, P.A.; Carter, B.S.; Feast, M.W.; Glass, I.S.; Laney, D.; Menzies, J.W.

    1984-01-01

    Extensive optical (UBVRI) and infrared (JHKL) photometry of Nova Mus 1983 obtained over a period of 300 days is tabulated. Infrared and optical spectra are described. Although by classical definition this was a fast nova its later development was slower than for typical objects of this class. Surprisingly the development of infrared thermal dust emission did not occur. Throughout the period covered, the infrared emission was characteristic of a bound-free plus free-free plasma continuum with emission lines. (author)

  17. Observation of Lorentzian lineshapes in the room temperature optical spectra of strongly coupled Jaggregate/metal hybrid nanostructures by linear two-dimensional optical spectroscopy

    International Nuclear Information System (INIS)

    Wang, Wei; Sommer, Ephraim; De Sio, Antonietta; Gross, Petra; Vogelgesang, Ralf; Lienau, Christoph; Vasa, Parinda

    2014-01-01

    We analyze the linear optical reflectivity spectra of a prototypical, strongly coupled metal/molecular hybrid nanostructure by means of a new experimental approach, linear two-dimensional optical spectroscopy. White-light, broadband spectral interferometry is used to measure amplitude and spectral phase of the sample reflectivity or transmission with high precision and to reconstruct the time structure of the electric field emitted by the sample upon impulsive excitation. A numerical analysis of this time-domain signal provides a two-dimensional representation of the coherent optical response of the sample as a function of excitation and detection frequency. The approach is used to study a nanostructure formed by depositing a thin J-aggregated dye layer on a gold grating. In this structure, strong coupling between excitons and surface plasmon polaritons results in the formation of hybrid polariton modes. In the strong coupling regime, Lorentzian lineshape profiles of different polariton modes are observed at room temperature. This is taken as an indication that the investigated strongly coupled polariton excitations are predominantly homogeneously broadened at room temperature. This new approach presents a versatile, simple and highly precise addition to nonlinear optical spectroscopic techniques for the analysis of line broadening phenomena. (paper)

  18. Optical spectra and radio properties of quasars

    International Nuclear Information System (INIS)

    Wills, B.J.

    1982-01-01

    Using high quality spectrophotometric scans obtained at the McDonald Observatory, and data from the literature the author shows that, for quasars, the relative strength of optical Fe II emission (the broad blended feature lambda4570) may be roughly inversely proportional to line widths (full width at half maximum, FWHM). A similar relation between the relative intensity of the UV Fe II blend between 2300 and 2600 A (the lambda2500 feature) and the widths of Mg II and Hβ is shown. She distinguishes between compact and extended radio sources and includes radio quiet quasars, Seyfert 1 galaxies and BLRG's. The quasars associated with extended radio sources have the broadest emission lines and the weakest Fe II, falling close to the region occupied by BLRG's which also have extended radio structure. Those quasars with strong Fe II and compact radio structure are most similar to the Seyfert 1 galaxies. (Auth.)

  19. Determination of rhenium (7) trace amounts by spectrophotometric titration in medium of mixed solvents

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Samorukova, O.L.

    1978-01-01

    The method has been proposed of determining rhenium (7) microamounts by spectrophotometric titration in the medium water-dimethyl-sulphoxide with the reagent nitrochromazo. The method is based on the formation of ionic pairs K + ReO 4 - in water-organic solvents. The results of rhenium determination are satisfactory in a wide concentration range up to 0.3 mkg in 15 ml which makes the method proposed close in sensitivity to photometric methods and much better in reproducibility

  20. Spectrophotometric determination of Fe(II) in Geological Materials by Using Ferrozine as Cromogenic Reagent

    International Nuclear Information System (INIS)

    Sanchez, D. M.; Martin, R.; Marin, J.; Morante, R.; Gutierrez, L.; Bayon, A.

    1999-12-01

    A rapid and sensitive spectrophotometric method for the determination of labile ferrous iron in geological materials is described. Samples are treated by boiling with hydrochloric acid for 60 min. in an atmosphere of carbon dioxide. Systematic erroneous results due to high concentrations of ferric iron are resolved. The limit of detection for the method was 0.02% of FeO. International standard granites analysed by the proposed method showed recoveries ranged from 81-102%. (Author) 9 refs

  1. Coherent optical transients observed in rubidium atomic line filtered Doppler velocimetry experiments

    Energy Technology Data Exchange (ETDEWEB)

    Fajardo, Mario E., E-mail: mario.fajardo@eglin.af.mil; Molek, Christopher D.; Vesely, Annamaria L. [Air Force Research Laboratory, Munitions Directorate, Ordnance Division, Energetic Materials Branch, AFRL/RWME, 2306 Perimeter Road, Eglin AFB, Florida 32542-5910 (United States)

    2015-10-14

    We report the first successful results from our novel Rubidium Atomic Line Filtered (RALF) Doppler velocimetry apparatus, along with unanticipated oscillatory signals due to coherent optical transients generated within pure Rb vapor cells. RALF is a high-velocity and high-acceleration extension of the well-known Doppler Global Velocimetry (DGV) technique for constructing multi-dimensional flow velocity vector maps in aerodynamics experiments [H. Komine, U.S. Patent No. 4,919,536 (24 April 1990)]. RALF exploits the frequency dependence of pressure-broadened Rb atom optical absorptions in a heated Rb/N{sub 2} gas cell to encode the Doppler shift of reflected near-resonant (λ{sub 0} ≈ 780.24 nm) laser light onto the intensity transmitted by the cell. The present RALF apparatus combines fiber optic and free-space components and was built to determine suitable operating conditions and performance parameters for the Rb/N{sub 2} gas cells. It yields single-spot velocities of thin laser-driven-flyer test surfaces and incorporates a simultaneous Photonic Doppler Velocimetry (PDV) channel [Strand et al., Rev. Sci. Instrum. 77, 083108 (2006)] for validation of the RALF results, which we demonstrate here over the v = 0 to 1 km/s range. Both RALF and DGV presume the vapor cells to be simple Beer's Law optical absorbers, so we were quite surprised to observe oscillatory signals in experiments employing low pressure pure Rb vapor cells. We interpret these oscillations as interference between the Doppler shifted reflected light and the Free Induction Decay (FID) coherent optical transient produced within the pure Rb cells at the original laser frequency; this is confirmed by direct comparison of the PDV and FID signals. We attribute the different behaviors of the Rb/N{sub 2} vs. Rb gas cells to efficient dephasing of the atomic/optical coherences by Rb-N{sub 2} collisions. The minimum necessary N{sub 2} buffer gas density ≈0.3 amagat translates into a

  2. Oxytetracycline as a new analytical reagent for the spectrophotometric determination of boron

    Energy Technology Data Exchange (ETDEWEB)

    Narayana, G L

    1984-05-01

    Oxytetracycline hydrochloride, Terramycin, is introduced as a new reagent for the spectrophotometric determination of trace quantities of boron in concentrated sulphuric acid medium. The reagent has an absorption maximum at 430 nm, and that of the boron complex at 520 nm. The colored system conformed to Beer's law between 2 and 10 ..mu..g of boron at 520 nm. The molar absorptivity calculated on the basis of boron is 10,800 1 mol/sup -1/ cm/sup -1/. The composition of the complex has been shown to be 1:1 both by the slope ratio and molar ratio methods. 16 references.

  3. Oxytetracycline as a new analytical reagent for the spectrophotometric determination of boron

    International Nuclear Information System (INIS)

    Narayana, G.L.

    1984-01-01

    Oxytetracycline hydrochloride, Terramycin, is introduced as a new reagent for the spectrophotometric determination of trace quantities of boron in concentrated sulphuric acid medium. The reagent has an absorption maximum at 430 nm, and that of the boron complex at 520 nm. The coloured system conformed to Beer's law between 2 and 10 μg of boron at 520 nm. The molar absorptivity calculated on the basis of boron is 10,800 1 mol -1 cm -1 . The composition of the complex has been shown to be 1:1 both by the slope ratio and molar ratio methods. (author)

  4. Optical and infrared observations of SU tau

    Energy Technology Data Exchange (ETDEWEB)

    Doroshenko, V T; Efimov, Yu S; Rozenbush, A E; Terebizh, V Yu; Shenavrin, V I [Krymskaya Stantsiya GAISh (Ukrainian SSR); AN SSSR, Crimea. Krymskaya Astrofizicheskaya Observatoriya; AN Ukrainskoj SSR, Kiev. Glavnaya Astronomicheskaya Observatoriya)

    1978-02-01

    The results of the narrow-band (with the resolution of 50-100A) and UBVJK photometry and optical linear polarimetry of SU Tau in 1974-1977 are given. The polarization observed is mainly an interstellar one. An estimation of A/sub V/ approximately equal to 1.3/sup m/-2,0/sub m/ for the interstellar absorption from polarization data leads to the absolute magnitude M/sub V/ approximately equal to - 3/sup m/ which is typical for the RCrB stars. Nearer to the light maximum the continuous spectrum of the star corresponds to that of a type not later than G1 supergiant. An excess of energy in the spectral region from 1.25 to 2.2 ..mu..m may be associated with 1000 K blackbody radiation of the dust. The decrease of the brightness of the star is apparently due to the shielding effect of a cloud of graphite particles with sizes of about 0.06 ..mu..m. The light reduced by 3/sup m/ needs a surface density of about 1.5x10/sup 10/ cm/sup -2/. The change of light is accompanied by complicated changes in color. The reddening is the most in the rising branch of light, which is also typical for other RCrB type stars.

  5. Diurnal variability in riverine dissolved organic matter composition determined by in situ optical measurement in the San Joaquin River (California, USA)

    Science.gov (United States)

    Spencer, R.G.M.; Pellerin, B.A.; Bergamaschi, B.A.; Downing, B.D.; Kraus, T.E.C.; Smart, D.R.; Dahlgren, R.A.; Hernes, P.J.

    2007-01-01

    Dissolved organic matter (DOM) concentration and composition in riverine and stream systems are known to vary with hydrological and productivity cycles over the annual and interannual time scales. Rivers are commonly perceived as homogeneous with respect to DOM concentration and composition, particularly under steady flow conditions over short time periods. However, few studies have evaluated the impact of short term variability ( DOC) measurement alone. The in situ optical measurements described in this study clearly showed for the first time diurnal variations in DOM measurements, which have previously been related to both composition and concentration, even though diurnal changes were not well reflected in bulk DOC concentrations. An apparent asynchronous trend of DOM absorbance and chlorophyll-a in comparison to chromophoric dissolved organic matter (CDOM) fluorescence and spectral slope S290-350 suggests that no one specific CDOM spectrophotometric measurement explains absolutely DOM diurnal variation in this system; the measurement of multiple optical parameters is therefore recommended. The observed diurnal changes in DOM composition, measured by in situ optical instrumentation likely reflect both photochemical and biologically-mediated processes. The results of this study highlight that short-term variability in DOM composition may complicate trends for studies aiming to distinguish different DOM sources in riverine systems and emphasizes the importance of sampling specific study sites to be compared at the same time of day. The utilization of in situ optical technology allows short-term variability in DOM dynamics to be monitored and serves to increase our understanding of its processing and fundamental role in the aquatic environment. Copyright ?? 2007 John Wiley & Sons, Ltd.

  6. Spectrophotometric study of the complexation equilibria of zirconium(IV) with 1-amino-4-hydroxyanthraquinone and the determination of zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Idriss, K A; Seleim, M M; Saleh, M S; Abu-Bakr, M S; Sedaira, Hassan

    1988-11-01

    The spectral absorption and acid-base characteristics of 1-amino-4-hydroxyanthraquinone (AMHA) were studied in water -ethanol media. The composition, molar absorptivities, equilibrium constants and stability constants of the chelates of this reagent with zirconium(IV) have been determined spectrophotometrically in 40% V/V ethanol at 20/sup 0/C and an ionic strength of 0.1 M (NaClO/sub 4/). Graphical logarithmic analysis of the absorbance graphs was used to demonstrate and characterise the complexation equilibria in solution. A simple, rapid, selective and sensitive method for the spectrophotometric determination of trace amounts of zirconium is proposed based on the formation of the Zr(AMHA)/sub 2/ complex at pH 3.5 (lambda/sub max/ = 600 nm, epsilon 1.621 x 10/sup 4/ l mol/sup -1/ cm/sup -1/). Interference caused by a number of ions was masked by the addition of cyanide ions.

  7. Time-temperature dependent variations in beta-carotene contents in carrot using different spectrophotometric techniques

    Science.gov (United States)

    Ullah, Rahat; Khan, Saranjam; Shah, Attaullah; Ali, Hina; Bilal, Muhammad

    2018-05-01

    The current study presents time dependent variations in the concentration of beta-carotene in carrot under different storage-temperature conditions using UV–VIS and Raman spectrophotometric techniques. The UV–VIS absorption spectra of beta-carotene extracted from carrot shows three distinct absorption peaks at 442, 467, and 500 nm with maximum absorption at 467 nm. These absorption peaks are very much reproducible and are assigned to β-carotene. Similarly, Raman spectra of carrot samples also confirmed the three main Raman peaks of beta-carotene at shift positions 1003, 1150, and 1515 cm‑1. An overall decrease in beta-carotene content has been observed for time-temperature conditions. These results depict a decrease of about 40% in the content of beta-carotene when carrot samples were stored in a refrigerator (4 °C) for the first 20 d, whereas a decrease of about 25% was observed when carrot samples were stored in a freezer (‑16 °C) for the same period. The objective of this study is to investigate the possible use of Raman spectroscopy and UV–VIS spectroscopy for quick and detailed analysis of changes (degradation) in beta-carotene content associated with time and temperature in storage (frozen foods) in order to promote quality foods for consumers. Future study with a greater focus on the concentration/content of beta-carotene in other fruits/vegetables is also desirable.

  8. Observation and simulation of an optically driven micromotor

    International Nuclear Information System (INIS)

    Metzger, N K; Mazilu, M; Dholakia, K; Kelemen, L; Ormos, P

    2011-01-01

    In the realm of low Reynolds number flow there is a need to find methods to pump, move and mix minute amounts of analyte. Interestingly, micro-devices performing such actuation can be initiated by means of the light–matter interaction. Light induced forces and torques are exerted on such micro-objects, which are then driven by the optical gradient or scattering force. Here, different driving geometries can be realized to harness the light induced force. For example, the scattering force enables micro-gears to be operated in a tangential setup where the micromotor rotors are in line with an optical waveguide. The operational geometry we investigate has the advantage that it reduces the complexity of the driving of such a device in a microfluidic environment by delivering the actuating light by means of a waveguide or fiber optic. In this paper we explore the case of a micromotor being driven by a fiber optically delivered light beam. We experimentally investigate how the driving light interacts with and diffracts from the motor, utilizing two-photon imaging. The micromotor rotation rate dependence on the light field parameters is explored. Additionally, a theoretical model based on the paraxial approximation is used to simulate the torque and predict the rotation rate of such a device and compare it with experiment. The results presented show that our model can be used to optimize the micromotor performance and some example motor designs are evaluated

  9. Observation and simulation of an optically driven micromotor

    Science.gov (United States)

    Metzger, N. K.; Mazilu, M.; Kelemen, L.; Ormos, P.; Dholakia, K.

    2011-04-01

    In the realm of low Reynolds number flow there is a need to find methods to pump, move and mix minute amounts of analyte. Interestingly, micro-devices performing such actuation can be initiated by means of the light-matter interaction. Light induced forces and torques are exerted on such micro-objects, which are then driven by the optical gradient or scattering force. Here, different driving geometries can be realized to harness the light induced force. For example, the scattering force enables micro-gears to be operated in a tangential setup where the micromotor rotors are in line with an optical waveguide. The operational geometry we investigate has the advantage that it reduces the complexity of the driving of such a device in a microfluidic environment by delivering the actuating light by means of a waveguide or fiber optic. In this paper we explore the case of a micromotor being driven by a fiber optically delivered light beam. We experimentally investigate how the driving light interacts with and diffracts from the motor, utilizing two-photon imaging. The micromotor rotation rate dependence on the light field parameters is explored. Additionally, a theoretical model based on the paraxial approximation is used to simulate the torque and predict the rotation rate of such a device and compare it with experiment. The results presented show that our model can be used to optimize the micromotor performance and some example motor designs are evaluated.

  10. Pre-seismic anomalies from optical satellite observations: a review

    Science.gov (United States)

    Jiao, Zhong-Hu; Zhao, Jing; Shan, Xinjian

    2018-04-01

    Detecting various anomalies using optical satellite data prior to strong earthquakes is key to understanding and forecasting earthquake activities because of its recognition of thermal-radiation-related phenomena in seismic preparation phases. Data from satellite observations serve as a powerful tool in monitoring earthquake preparation areas at a global scale and in a nearly real-time manner. Over the past several decades, many new different data sources have been utilized in this field, and progressive anomaly detection approaches have been developed. This paper reviews the progress and development of pre-seismic anomaly detection technology in this decade. First, precursor parameters, including parameters from the top of the atmosphere, in the atmosphere, and on the Earth's surface, are stated and discussed. Second, different anomaly detection methods, which are used to extract anomalous signals that probably indicate future seismic events, are presented. Finally, certain critical problems with the current research are highlighted, and new developing trends and perspectives for future work are discussed. The development of Earth observation satellites and anomaly detection algorithms can enrich available information sources, provide advanced tools for multilevel earthquake monitoring, and improve short- and medium-term forecasting, which play a large and growing role in pre-seismic anomaly detection research.

  11. Hydrodynamic cavitation in microsystems. II. Simulations and optical observations

    Science.gov (United States)

    Medrano, M.; Pellone, C.; Zermatten, P. J.; Ayela, F.

    2012-04-01

    Numerical calculations in the single liquid phase and optical observations in the two-phase cavitating flow regime have been performed on microdiaphragms and microventuris fed with deionized water. Simulations have confirmed the influence of the shape of the shrinkage upon the contraction of the jet, and so on the localisation of possible cavitating area downstream. Observations of cavitating flow patterns through hybrid silicon-pyrex microdevices have been performed either via a laser excitation with a pulse duration of 6 ns, or with the help of a high-speed camera. Recorded snapshots and movies are presented. Concerning microdiaphragms, it is confirmed that very high shear rates downstream the diaphragms are the cause of bubbly flows. Concerning microventuris, a gaseous cavity forms on a boundary downstream the throat. As a consequence of a microsystem instability, the cavity displays a high frequency pulsation. Low values Strouhal numbers are associated to such a sheet cavitation. Moreover, when the intensity of the cavitating flow is reduced, there is a mismatch between the frequency of the pulsation of the cavity and the frequency of shedded clouds downstream the channel. That may be the consequence of viscous effects limiting the impingement of a re-entrant liquid jet on the attached cavity.

  12. Experimental observation of the optical spin transfer torque

    Czech Academy of Sciences Publication Activity Database

    Němec, P.; Rozkotová, E.; Tesařová, N.; Trojánek, F.; De Ranieri, E.; Olejník, Kamil; Zemen, Jan; Novák, Vít; Cukr, Miroslav; Malý, P.; Jungwirth, Tomáš

    2012-01-01

    Roč. 8, č. 5 (2012), s. 411-415 ISSN 1745-2473 R&D Projects: GA ČR GD202/09/H041; GA MŠk LC510 EU Projects: European Commission(XE) 268066 - 0MSPIN; European Commission(XE) 215368 - SemiSpinNet Grant - others:AV ČR(CZ) AP0801 Program:Akademická prémie - Praemium Academiae Institutional research plan: CEZ:AV0Z10100521 Keywords : magneto-optics * magnetization dynamics * ferromagnetic semiconductors Subject RIV: BH - Optics, Masers, Lasers Impact factor: 19.352, year: 2012 http://arxiv.org/abs/1201.1436

  13. Indirect spectrophotometric determination of arbutin, whitening agent through oxidation by periodate and complexation with ferric chloride

    Science.gov (United States)

    Barsoom, B. N.; Abdelsamad, A. M. E.; Adib, N. M.

    2006-07-01

    A simple and accurate spectrophotometric method for the determination of arbutin (glycosylated hydroquinone) is described. It is based on the oxidation of arbutin by periodate in presence of iodate. Excess periodate causes liberation of iodine at pH 8.0. The unreacted periodate is determined by measurement of the liberated iodine spectrophotometrically in the wavelength range (300-500 nm). A calibration curve was constructed for more accurate results and the correlation coefficient of linear regression analysis was -0.9778. The precision of this method was better than 6.17% R.S.D. ( n = 3). Regression analysis of Bear-Lambert plot shows good correlation in the concentration range 25-125 ug/ml. The identification limit was determined to be 25 ug/ml a detailed study of the reaction conditions was carried out, including effect of changing pH, time, temperature and volume of periodate. Analyzing pure and authentic samples containing arbutin tested the validity of the proposed method which has an average percent recovery of 100.86%. An alternative method is also proposed which involves a complexation reaction between arbutin and ferric chloride solution. The produced complex which is yellowish-green in color was determined spectophotometrically.

  14. Spectrophotometric study of bio-sorption of uranium on glass grade spodumene shell powder

    International Nuclear Information System (INIS)

    Parakudyil, A.S.; Pillai, A.K.; Reddy, A.V.R.; Singal, R.K.; Sharma, P.K.; Michael, K.M.

    2012-01-01

    Separation of uranium found in iron ore leachates was done by extraction chromatography using glass grade spodumene shellpowder (GSS) in nitric acid medium and analyzed spectrophotometrically. The influences of metal ion concentration, pH and adsorption capacity of biomass were investigated. Biosorption is a potential method of separation of heavy and trace metals from waste water and effluents from various sources. The adsorption capacities of biomass were investigated by batch experiments and column experiments. In the present study, glass grade spodumene shell powder (GSS) in acidic medium is being used as a biosorbent

  15. Potentiometric and spectrophotometric titration study of interaction of tungstovanadophosphoric heteropolyacids with sodium hydroxide

    International Nuclear Information System (INIS)

    Borkoyakov, S.A.; Fisun, L.A.

    1988-01-01

    The methods of potentiometric and spectrophotometric titration are used to study H s+n PW 12-n V n O 40 (n=1,2) (P-W-V HPA) decomposition by sodium hydroxide. It is shown that at the first stage of heteropolyanion interaction with alkali (pH) > 4 P-W-V HPA structural reconstruction takes place. It is accompanied by the formation of complexes with a higher content of vanadium atoms stable at pH 4-7/ P-W-V HPA decomposition to initial salts occurs at pH > 8

  16. Dose intercomparison for 400–500 keV electrons using FWT-60 film and glutamine (spectrophotometric readout) dosimeters

    DEFF Research Database (Denmark)

    Gupta, B. L.; Nilekani, S. R.; Gehringer, P.

    1986-01-01

    This paper describes the dose and the depth dose measurements with FWT-60 film and glutamine (Spectrophotometric readout) dosimeters for 400–500 keV electrons. The glutamine powder was spread uniformly in polyethylene bags and the powder thickness in each bag was 5 mg cm−2. Both techniques show...

  17. Influence of all-ceramic and porcelain-fused-to-metal restorations on peri-implant gingival discoloration:a spectrophotometric comparison

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2013-01-01

    discoloration scores were evaluated by clinician. SPSS17.0 was used to analyze the data. RESULTS: There was no significant difference between the all-ceramic group (3.4+1.8) and PFM group (4.9+3.4) spectrophotometrically. No significant difference was found between the all-ceramic restorations and PFM...

  18. On-line Speciation of Cr(III) and Cr(VI) by Flow Injection Analysis With Spectrophotometric Detection and Chemometrics

    DEFF Research Database (Denmark)

    Diacu, Elena; Andersen, Jens Enevold Thaulov

    2003-01-01

    A flow injection system has been developed, for on-line speciation. of Cr(III) and Cr(VI) by the Diphenylcarbazide (DPC) method with H2O2 oxidation followed by spectrophotometric detection at the 550 nm wavelength. The data thus obtained were subjected to a chemometric analysis (PLS), which showe...

  19. From thermometric to spectrophotometric kinetic-catalytic methods of analysis. A review.

    Science.gov (United States)

    Cerdà, Víctor; González, Alba; Danchana, Kaewta

    2017-05-15

    Kinetic-catalytic analytical methods have proved to be very easy and highly sensitive strategies for chemical analysis, that rely on simple instrumentation [1,2]. Molecular absorption spectrophotometry is commonly used as the detection technique. However, other detection systems, like electrochemical or thermometric ones, offer some interesting possibilities since they are not affected by the color or turbidity of the samples. In this review some initial experience with thermometric kinetic-catalytic methods is described, up to our current experience exploiting spectrophotometric flow techniques to automate this kind of reactions, including the use of integrated chips. Procedures for determination of inorganic and organic species in organic and inorganic matrices are presented. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Study of an integral field spectrograph for the SNAP satellite. Prototype, simulation and performances

    International Nuclear Information System (INIS)

    Aumeunier, Marie-Helene

    2007-01-01

    The SNAP (Supernovae/Acceleration Probe) project plans to measure very precisely the cosmological parameters and to determine the nature of dark energy by observations of type Ia supernovae and weak lensing. The SNAP instrument consists in a 2-meter telescope with a one square-degree imager and a spectrograph in the visible and infrared range. A dedicated optimized integral field spectrograph based on an imager slicer technology has been developed. To test and validate the performances, two approaches have been developed: a complete simulation of the complete instrument at the pixel level and the manufacturing and test of a spectrograph prototype operating at room temperature and in cryogenic environment. In this thesis we will test the optical and functional performances of the SNAP spectrograph: especially diffraction losses, stray-light and spectro-photometric calibration. We present an original approach for the spectro-photometric calibration adapted for the slicer and the optical performances resulting from the first measurement campaign in the visible range. (author) [fr

  1. Macrophysical and optical properties of mid-latitude cirrus clouds over a semi-arid area observed by micro-pulse lidar

    International Nuclear Information System (INIS)

    Wang, Jin; Zhang, Lei; Huang, Jianping; Cao, Xianjie; Liu, Ruijin; Zhou, Bi; Wang, Hongbin; Huang, Zhongwei; Bi, Jianrong; Zhou, Tian; Zhang, Beidou; Wang, Tengjiao

    2013-01-01

    Macrophysical and optical characteristics of cirrus clouds were investigated at the Semi-Arid Climate Observatory and Laboratory (SACOL; 35.95°N, 104.14°E) of Lanzhou University in northwest China during April to December 2007 using micro-pulse lidar data and profiling radiometer measurements. Analysis of the measurements allowed the determination of macrophysical properties such as cirrus cloud height, ambient temperature, and geometrical depth, and optical characteristics were determined in terms of optical depth, extinction coefficient, and lidar ratio. Cirrus clouds were generally observed at heights ranging from 5.8 to 12.7 km, with a mean of 9.0±1.0 km. The mean cloud geometrical depth and optical depth were found to be 2.0±0.6 km and 0.350±0.311, respectively. Optical depth increased linearly with increasing geometrical depth. The results derived from lidar signals showed that cirrus over SACOL consisted of thin cirrus and opaque cirrus which occurred frequently in the height of 8–10 km. The lidar ratio varied from 5 to 70 sr, with a mean value of 26±16 sr, after taking into account multiple scattering effects. The mean lidar ratio of thin cirrus was greater than that of opaque cirrus. The maximum lidar ratio appeared between 0.058 and 0.3 when plotted against optical depth. The lidar ratio increased exponentially as the optical depth increased. The maximum lidar ratio fell between 11 and 12 km when plotted against cloud mid-height. The lidar ratio first increased and then decreased with increasing mid-height. -- Highlights: ► Cirrus clouds over semi-arid area were firstly observed by ground-based lidar. ► Macrophysical and optical characteristics of cirrus clouds were discussed. ► Thin cirrus and opaque cirrus occurred most frequently over SACOL. ► Thin cirrus often occurred above 10 km

  2. Observer Performance in the Use of Digital and Optical Microscopy for the Interpretation of Tissue-Based Biomarkers

    Directory of Open Access Journals (Sweden)

    Marios A. Gavrielides

    2014-01-01

    Full Text Available Background. We conducted a validation study of digital pathology for the quantitative assessment of tissue-based biomarkers with immunohistochemistry. Objective.\tTo examine observer agreement as a function of viewing modality (digital versus optical microscopy, whole slide versus tissue microarray (TMA review, biomarker type (HER2 incorporating membranous staining and Ki-67 with nuclear staining, and data type (continuous and categorical. Methods.\tEight pathologists reviewed 50 breast cancer whole slides (25 stained with HER2 and 25 with Ki-67 and 2 TMAs (1 stained with HER2, 1 with Ki-67, each containing 97 cores, using digital and optical microscopy. Results. Results showed relatively high overall interobserver and intermodality agreement, with different patterns specific to biomarker type. For HER2, there was better interobserver agreement for optical compared to digital microscopy for whole slides as well as better interobserver and intermodality agreement for TMAs. For Ki-67, those patterns were not observed. Conclusions. The differences in agreement patterns when examining different biomarkers and different scoring methods and reviewing whole slides compared to TMA stress the need for validation studies focused on specific pathology tasks to eliminate sources of variability that might dilute findings. The statistical uncertainty observed in our analyses calls for adequate sampling for each individual task rather than pooling cases.

  3. Dwarf novae in outburst: simultaneous ultraviolet and optical observations of VW Hydri

    International Nuclear Information System (INIS)

    Schwarzenberg-Czerny, A.; Jones, D.H.P.; Ward, M.; Pringle, J.E.; Verbunt, F.

    1985-01-01

    Simultaneous spectrophotometry of the dwarf nova VW Hydri in the range 1200-7000 A is presented. The main set of observations cover one complete outburst, including the rise and the decline. Comparing these data with data from other outbursts of VW Hyi it is found that all the data can be interleaved. This underlines the similarity in the behaviour of the continuum flux distribution from outburst to outburst. In particular the discovery by previous authors that the outburst starts at optical wavelengths and spreads later to the ultraviolet is confirmed. (author)

  4. Spectrophotometric investigation of vanadium(4) complexing with monoamine complexones

    International Nuclear Information System (INIS)

    Merkulov, D.A.; Kornev, V.I.

    1998-01-01

    Interaction of vanadium(4) with iminodiacetic (H 2 Ida) and methyliminodiacetic (H 2 Mida) acids by μ = 0.1 (NaClO 4 ) and t = 20±2 deg C is studied through the spectrophotometric method. It is established that the process of complex formation in quasi-binary systems due to competitive effect of hydroxide ions depends to a large degree on the ligands concentration and properties. The VOIda, VO(OH)Ida - , VOMida, VO(OH)Mida - complexes are identified. The stability constants logarithms of these complexes are equal correspondingly to 9.81±0.02, 18.19±0.03, 10.15±0.03, 18.34±0.02. The results of the study on the VO 2+ -HIda and VO 2+ -H 2 Mida systems agree well with the regularities, identified by the study on the vanadium(4) complex formation with other complexones of the iminodiacetate series

  5. An efficient absorbing system for spectrophotometric determination of nitrogen dioxide

    Science.gov (United States)

    Kaveeshwar, Rachana; Amlathe, Sulbha; Gupta, V. K.

    A simple and sensitive spectrophotometric method for determination of atmospheric nitrogen dioxide using o-nitroaniline as an efficient absorbing, as well as diazotizing, reagent is described. o-Nitroaniline present in the absorbing medium is diazotized by the absorbed nitrite ion to form diazonium compound. This is later coupled with 1-amino-2-naphthalene sulphonic acid (ANSA) in acidic medium to give red-violet-coloured dye,having λmax = 545 nm. The isoamyl extract of the red azo dye has λmax = 530 nm. The proposed reagents has ≈ 100% collection efficiency and the stoichiometric ratio of NO 2:NO 2- is 0.74. The other important analytical parameters have been investigated. By employing solvent extraction the sensitivity of the reaction was increased and up to 0.03 mg m -3 nitrogen dioxide could be estimated.

  6. Determination of lisinopril in pharmaceuticals by a kinetic spectrophotometric method

    Directory of Open Access Journals (Sweden)

    Čakar Mira

    2012-01-01

    Full Text Available A kinetic spectrophotometric method for determination of lisinopril in pharmaceuticals has been developed. The method is based on activator action of lisinopril on Cu(II ions catalysing the oxidation of nile blue A with hydrogen peroxide in borate buffer (pH 9.3. A decrease of the absorbance was recorded at 635 nm for 5 min at 25°C. The linearity was established applying the tangent method within the concentration range of lisinopril from 0.8-6.4 μg mL-1, the detection and quantification limits being 0.158 μg mL-1 and 0.480 μg mL-1, respectively. The method has been successfully applied in three brands of tablets containing lisinopril alone or in combination with hydrochlorothiazide.

  7. Spectrophotometric study of lanthanoid complexes with antipyrine and salicylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Tishchenko, M A; Gerasimenko, G I; Poluehktov, N S [AN Ukrainskoj SSR, Odessa. Fiziko-Khimicheskij Inst.

    1981-01-01

    The extraction-spectrophotometric method has been used to study lanthanoid ion complexing (Pr, Nd, Ho and Er) with antipyrine (Ant) and salicylic acid (Sal). The component relationship in different-ligand compounds Ln:Ant:Sal=2:3:6 and solvate number equal to 5 are determined; molar extinction coefficients of binary and different-ligand compounds are calculated. Oscillator strengths of absorption bands corresponding to supersensitive transitions of neodymium, holmium, erbium and some most intensive praseodymium bands are calculated. The study of IR spectra of investigated compounds allows to conclude on formation of coordination bonds of the central atom with the antipyrine molecule through the oxygen of the carbonyl group as well as on carboxyl group hydrogen substitution for metal and formation of coordination bond with OH group in salicylic acid molecules.

  8. Spectrophotometric study of lanthanoid complexes with antipyrine and salicylic acid

    International Nuclear Information System (INIS)

    Tishchenko, M.A.; Gerasimenko, G.I.; Poluehktov, N.S.

    1981-01-01

    The extraction-spectrophotometric method has been used to study lanthanoid ion complexing (Pr, Nd, Ho and Er) with antipyrine (Ant) and salicylic acid (Sal). The component relationship in different-ligand compounds Ln:Aut:Sal=2:3:6 and solvate number equal to 5 are determined; molar extinction coefficients of binary and different-ligand compounds are calculated. Oscillator strengths of absorption bands corresponding to supersensitive transitions of neodymium, holmium, erbium and some most intensive praseodymium bands are calculated. The study of IR spectra of investigated compounds allows to conclude on formation of coordination bonds of the central atom with the antipyrine molecule through the oxygen of the carbonyl group as well as on carboxyl group hydrogen substitution for metal and formation of coordination bond with OH group in salicylic acid molecules [ru

  9. Quantitative HPLC Analysis of Rosmarinic Acid in Extracts of "Melissa officinalis" and Spectrophotometric Measurement of Their Antioxidant Activities

    Science.gov (United States)

    Canelas, Vera; da Costa, Cristina Teixeira

    2007-01-01

    The students prepare tea samples using different quantities of lemon balm leaves ("Melissa officinalis") and measure the rosmarinic acid contents by an HPLC-DAD method. The antioxidant properties of the tea samples are evaluated by a spectrophotometric method using a radical-scavenging assay with DPPH. (2,2-diphenyl-1-picrylhydrazyl). Finally the…

  10. OPTICAL SPECTROSCOPIC OBSERVATIONS OF GAMMA-RAY BLAZAR CANDIDATES. IV. RESULTS OF THE 2014 FOLLOW-UP CAMPAIGN

    International Nuclear Information System (INIS)

    Ricci, F.; Massaro, F.; Landoni, M.; D’Abrusco, R.; Milisavljevic, D.; Paggi, A.; Smith, Howard A.; Stern, D.; Masetti, N.; Tosti, G.

    2015-01-01

    The extragalactic γ-ray sky is dominated by the emission arising from blazars, one of the most peculiar classes of radio-loud active galaxies. Since the launch of Fermi several methods were developed to search for blazars as potential counterparts of unidentified γ-ray sources (UGSs). To confirm the nature of the selected candidates, optical spectroscopic observations are necessary. In 2013 we started a spectroscopic campaign to investigate γ-ray blazar candidates selected according to different procedures. The main goals of our campaign are: (1) to confirm the nature of these candidates, and (2) whenever possible, determine their redshifts. Optical spectroscopic observations will also permit us to verify the robustness of the proposed associations and check for the presence of possible source class contaminants to our counterpart selection. This paper reports the results of observations carried out in 2014 in the northern hemisphere with Kitt Peak National Observatory and in the southern hemisphere with the Southern Astrophysical Research telescopes. We also report three sources observed with the Magellan and Palomar telescopes. Our selection of blazar-like sources that could be potential counterparts of UGSs is based on their peculiar infrared colors and on their combination with radio observations both at high and low frequencies (i.e., above and below ∼1 GHz) in publicly available large radio surveys. We present the optical spectra of 27 objects. We confirm the blazar-like nature of nine sources that appear to be potential low-energy counterparts of UGSs. Then we present new spectroscopic observations of 10 active galaxies of uncertain type associated with Fermi sources, classifying all of them as blazars. In addition, we present the spectra for five known γ-ray blazars with uncertain redshift estimates and three BL Lac candidates that were observed during our campaign. We also report the case for WISE J173052.85−035247.2, candidate counterpart of the

  11. OPTICAL SPECTROSCOPIC OBSERVATIONS OF GAMMA-RAY BLAZAR CANDIDATES. IV. RESULTS OF THE 2014 FOLLOW-UP CAMPAIGN

    Energy Technology Data Exchange (ETDEWEB)

    Ricci, F. [Dipartimento di Matematica e Fisica, Università Roma Tre, via della Vasca Navale 84, I-00146, Roma (Italy); Massaro, F. [Dipartimento di Fisica, Università degli Studi di Torino, via Pietro Giuria 1, I-10125 Torino (Italy); Landoni, M. [INAF-Osservatorio Astronomico di Brera, Via Emilio Bianchi 46, I-23807 Merate (Italy); D’Abrusco, R.; Milisavljevic, D.; Paggi, A.; Smith, Howard A. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Stern, D. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Mail Stop 169-221, Pasadena, CA 91109 (United States); Masetti, N. [INAF-Istituto di Astrofisica Spaziale e Fisica Cosmica di Bologna, via Gobetti 101, I-40129, Bologna (Italy); Tosti, G., E-mail: riccif@fis.uniroma3.it [Dipartimento di Fisica, Università degli Studi di Perugia, I-06123 Perugia (Italy)

    2015-05-15

    The extragalactic γ-ray sky is dominated by the emission arising from blazars, one of the most peculiar classes of radio-loud active galaxies. Since the launch of Fermi several methods were developed to search for blazars as potential counterparts of unidentified γ-ray sources (UGSs). To confirm the nature of the selected candidates, optical spectroscopic observations are necessary. In 2013 we started a spectroscopic campaign to investigate γ-ray blazar candidates selected according to different procedures. The main goals of our campaign are: (1) to confirm the nature of these candidates, and (2) whenever possible, determine their redshifts. Optical spectroscopic observations will also permit us to verify the robustness of the proposed associations and check for the presence of possible source class contaminants to our counterpart selection. This paper reports the results of observations carried out in 2014 in the northern hemisphere with Kitt Peak National Observatory and in the southern hemisphere with the Southern Astrophysical Research telescopes. We also report three sources observed with the Magellan and Palomar telescopes. Our selection of blazar-like sources that could be potential counterparts of UGSs is based on their peculiar infrared colors and on their combination with radio observations both at high and low frequencies (i.e., above and below ∼1 GHz) in publicly available large radio surveys. We present the optical spectra of 27 objects. We confirm the blazar-like nature of nine sources that appear to be potential low-energy counterparts of UGSs. Then we present new spectroscopic observations of 10 active galaxies of uncertain type associated with Fermi sources, classifying all of them as blazars. In addition, we present the spectra for five known γ-ray blazars with uncertain redshift estimates and three BL Lac candidates that were observed during our campaign. We also report the case for WISE J173052.85−035247.2, candidate counterpart of the

  12. Observation of self-assembled fluorescent beads by scanning near-field optical microscopy and atomic force microscopy

    International Nuclear Information System (INIS)

    Oh, Y.J.; Jo, W.; Kim, Min-Gon; Kyu Park, Hyun; Hyun Chung, Bong

    2006-01-01

    Optical response and topography of fluorescent latex beads both on flat self-assembled monolayer and on a micron-patterned surface with poly(dimethylsiloxane) are studied. Scanning near-field optical microscopy and atomic force microscopy were utilized together for detecting fluorescence and imaging topography of the patterned latex beads, respectively. As a result, the micro-patterned latex beads where a specific chemical binding occurred show a strong signal, whereas no signals are observed in the case of nonspecific binding. With fluorescein isothiocyanate (FITC), it is convenient to measure fluorescence signal from the patterned beads allowing us to monitor the small balls of fluorescent latex

  13. Azeotropic mixture used for development and validation of Lornoxicam in bulk and its tablet dosage form by spectrophotometric method

    Directory of Open Access Journals (Sweden)

    Prajesh Prajapati

    2012-08-01

    Full Text Available A novel, safe, economic and sensitive method of spectrophotometric estimation has been developed using Azeoptropic mixture (water:methanol: 60:40, v/v for the quantitative determination of Lornoxicam, a practically water-insoluble drug. Hence, Lornoxicam stock solution was prepared in Azeoptropic mixture. Lornoxicam showed maximum absorbance at 383 nm. Beer's law was obeyed in the concentration range 4–24 μg/mL with regression coefficient of 0.999. The method was validated in terms of linearity (R2=0.999, precision (CV for intra-day and inter-day was 0.28–0.68 and 0.12–0.92, respectively, accuracy (98.03–100.59% w/w and specificity. This method is simple, precise, accurate, sensitive and reproducible and can be used for the routine quality control testing of the marketed formulations. Keywords: Analgesic, Chlortenoxicam, Lornoxicam, Oxicam, Spectrophotometric, Azeotropic mixture

  14. Far-infared spectroscopic observations with a Balloon-Borne infrared telescope

    International Nuclear Information System (INIS)

    Maihara, Toshinori; Takami, Hideki; Mizutani, Kohei

    1986-01-01

    The first observations of far-infrared celestial objects using the 50-cm Balloon-Borne Infrared Telescope were made in Alice Springs, Australia. Far-infrared spectrophotometric data between 45 and 115 μm were taken for the Orion-KL region, Saturn and a southern H II region RCW 38. The data including high excitation transition lines of CO for Orion-KL, O III lines for RCW 38 and a PH 3 absorption feature of Saturn will be presented. (author)

  15. Suzaku And Multi-Wavelength Observations of OJ 287 During the Periodic Optical Outburst in 2007

    Energy Technology Data Exchange (ETDEWEB)

    Seta, Hiromi; /Saitama U.; Isobe, N.; /Kyoto U.; Tashiro, Makoto S.; /Saitama U.; Yaji, Yuichi; /Saitama U.; Arai, Akira; /Hiroshima U.; Fukuhara, Masayuki; /Tokyo U. /Grad. U. for Adv. Stud., Nagano; Kohno, Kotaro; /Tokyo U.; Nakanishi, Koichiro; /Grad. U. for Adv. Stud., Nagano; Sasada, Mahito; /Hiroshima U.; Shimajiri, Yoshito; /Tokyo U. /Grad. U. for Adv. Stud., Nagano; Tosaki, Tomoka; /Grad. U. for Adv. Stud., Nagano; Uemura, Makoto; /Hiroshima U.; Anderhub, Hans; /Zurich, ETH; Antonelli, L.A.; /INFN, Rome; Antoranz, Pedro; /Madrid U.; Backes, Michael; /Dortmund U.; Baixeras, Carmen; /Barcelona, Autonoma U.; Balestra, Silvia; /Madrid U.; Barrio, Juan Abel; /Madrid U.; Bastieri, Denis; /Padua U. /INFN, Padua; Becerra Gonzalez, Josefa; /IAC, La Laguna /Dortmund U. /Lodz U. /Lodz U. /DESY /Zurich, ETH /Munich, Max Planck Inst. /Padua U. /INFN, Padua /Siena U. /INFN, Siena /Barcelona, IEEC /Munich, Max Planck Inst. /Barcelona, IEEC /Madrid U. /Zurich, ETH /Wurzburg U. /Zurich, ETH /Madrid U. /Munich, Max Planck Inst. /Zurich, ETH /Madrid U. /Barcelona, IFAE /IAC, La Laguna /Laguna U., Tenerife /INFN, Rome /Dortmund U. /Udine U. /INFN, Udine /INFN, Padua /Udine U. /INFN, Udine /Barcelona, IEEC /Madrid U. /Udine U. /INFN, Udine /Udine U. /INFN, Udine /Udine U. /INFN, Udine /IAC, La Laguna /Madrid, CIEMAT /Sierra Nevada Observ. /Zurich, ETH /Padua U. /INFN, Padua /Wurzburg U. /Barcelona, IFAE /UC, Davis /Barcelona, IFAE /Barcelona, IFAE /Madrid U. /Barcelona, Autonoma U. /Munich, Max Planck Inst. /IAC, La Laguna /Laguna U., Tenerife /Barcelona, IFAE /IAC, La Laguna /Munich, Max Planck Inst. /Barcelona, Autonoma U. /Munich, Max Planck Inst. /SLAC /IAC, La Laguna /Laguna U., Tenerife /Zurich, ETH /Wurzburg U. /Munich, Max Planck Inst. /Munich, Max Planck Inst. /Munich, Max Planck Inst. /Zurich, ETH /INFN, Rome /UC, Davis /Siena U. /INFN, Siena /Turku U. /Padua U. /INFN, Padua /Udine U. /INFN, Udine /Padua U. /INFN, Padua /Zurich, ETH /Munich, Max Planck Inst. /DESY /Sofiya, Inst. Nucl. Res. /Udine U. /INFN, Udine /Wurzburg U. /INFN, Rome /Padua U. /INFN, Padua /Barcelona, IFAE /Barcelona, IFAE /Siena U. /INFN, Siena /Wurzburg U. /Madrid U. /Munich, Max Planck Inst. /Munich, Max Planck Inst. /Barcelona, IEEC /Sierra Nevada Observ. /Barcelona, IFAE /Madrid U. /Turku U. /Munich, Max Planck Inst. /Munich, Max Planck Inst. /UC, Santa Cruz /Madrid U. /Siena U. /INFN, Siena /Barcelona, IEEC /Turku U. /Padua U. /INFN, Padua /Zurich, ETH /Siena U. /INFN, Siena /Sierra Nevada Observ. /Udine U. /INFN, Udine /INFN, Trieste /Padua U. /INFN, Padua /Sierra Nevada Observ. /Padua U. /INFN, Padua /Barcelona, IFAE /Barcelona, IFAE /Dortmund U. /Barcelona, IEEC /ICREA, Barcelona /Barcelona, IFAE /Zurich, ETH /Barcelona, Autonoma U. /Wurzburg U. /Padua U. /INFN, Padua /Munich, Max Planck Inst. /INFN, Rome /Sierra Nevada Observ. /DESY /Padua U. /INFN, Padua /Udine U. /INFN, Udine /Munich, Max Planck Inst. /Munich, Max Planck Inst. /Pisa U. /INFN, Pisa /Barcelona, IFAE /Barcelona, IEEC /Turku U. /Munich, Max Planck Inst. /Lodz U. /Lodz U. /Wurzburg U. /Siena U. /INFN, Siena /Zurich, ETH /Turku U. /INFN, Rome /Sofiya, Inst. Nucl. Res. /Barcelona, IFAE /Munich, Max Planck Inst. /DESY /ICREA, Barcelona /Barcelona, IEEC /Siena U. /INFN, Siena /Sofiya, Inst. Nucl. Res. /Munich, Max Planck Inst. /Munich, Max Planck Inst. /Barcelona, IEEC /Sierra Nevada Observ. /Barcelona, IFAE /Barcelona, Autonoma U.

    2011-12-01

    Suzaku observations of the blazar OJ 287 were performed in 2007 April 10-13 and November 7-9. They correspond to a quiescent and a flaring state, respectively. The X-ray spectra of the source can be well described with single power-law models in both exposures. The derived X-ray photon index and the flux density at 1 keV were found to be {Lambda} = 1.65 {+-} 0.02 and S{sub 1keV} = 215 {+-} 5 nJy, in the quiescent state. In the flaring state, the source exhibited a harder X-ray spectrum ({Lambda} = 1.50 {+-} 0.01) with a nearly doubled X-ray flux density S{sub 1keV} = 404{sub -5}{sup +6} nJy. Moreover, significant hard X-ray signals were detected up to {approx} 27 keV. In cooperation with the Suzaku, simultaneous radio, optical, and very-high-energy {gamma}-ray observations of OJ 287 were performed with the Nobeyama Millimeter Array, the KANATA telescope, and the MAGIC telescope, respectively. The radio and optical fluxes in the flaring state (3.04 {+-} 0.46 Jy and 8.93 {+-} 0.05 mJy at 86.75 Hz and in the V-band, respectively) were found to be higher by a factor of 2-3 than those in the quiescent state (1.73 {+-} 0.26 Jy and 3.03 {+-} 0.01 mJy at 86.75 Hz and in the V-band, respectively). No notable {gamma}-ray events were detected in either observation. The spectral energy distribution of OJ 287 indicated that the X-ray spectrum was dominated by inverse Compton radiation in both observations, while synchrotron radiation exhibited a spectral cutoff around the optical frequency. Furthermore, no significant difference in the synchrotron cutoff frequency was found between the quiescent and flaring states. According to a simple synchrotron self-Compton model, the change of the spectral energy distribution is due to an increase in the energy density of electrons with small changes of both the magnetic field strength and the maximum Lorentz factor of electrons.

  16. Simultaneous observation of cavitation bubbles generated in biological tissue by high-speed optical and acoustic imaging methods

    Science.gov (United States)

    Suzuki, Kai; Iwasaki, Ryosuke; Takagi, Ryo; Yoshizawa, Shin; Umemura, Shin-ichiro

    2017-07-01

    Acoustic cavitation bubbles are useful for enhancing the heating effect in high-intensity focused ultrasound (HIFU) treatment. Many studies were conducted to investigate the behavior of such bubbles in tissue-mimicking materials, such as a transparent gel phantom; however, the detailed behavior in tissue was still unclear owing to the difficulty in optical observation. In this study, a new biological phantom was developed to observe cavitation bubbles generated in an optically shallow area of tissue. Two imaging methods, high-speed photography using light scattering and high-speed ultrasonic imaging, were used for detecting the behavior of the bubbles simultaneously. The results agreed well with each other for the area of bubble formation and the temporal change in the region of bubbles, suggesting that both methods are useful for visualizing the bubbles.

  17. Spectrophotometric Determination of Doxycycline Hyclate in Pure and Capsule using Diazotization Reaction

    Directory of Open Access Journals (Sweden)

    Ruba Fahmi Abbas

    2017-07-01

    Full Text Available A sensitive spectrophotometric method has been developed for the determination of Doxycycline hyclate (DCH as pure and  capsule forms. This method is based on diazotization of primary amine group of benzocaine with sodium nitrite in hydrochloric acid medium; the formed diazonium salt is then reacted with DCH in sodium hydroxide medium, to form yellow – orange Azo dye. Beer's law is obeyed in the concentration rang 16-34mg. ml-1 at 480 nm with detection limit LOD and molar absorptivity Є were found to be 0.418 mg.ml-1 and 2.214× 10+4 L.mol-1.cm-1, respectively.

  18. Indirect spectrophotometric determination of BIDA, DISIDA, DTPA and MDP in labelled compounds

    International Nuclear Information System (INIS)

    Van der Walt, T.N.; Coetzee, P.P.

    1989-01-01

    N-(4-(n-butyl)acetanilide)iminodiacetic acid (BIDA), N-(2,6-diisopropylacetanilide)iminodiacetic acid (DISDA), diethylenetriaminepentaacetic acid (DTPA) and methylene diphosphonic acid (MDP) are used in labelling kits. The contents of BIDA, DISIDA or MDP of the 99m Tc-labelled compounds can be determined (indirectly) spectrophotometrically with copper, eriochrome cyanine R (ECC) and dodecyl-ethyldimethylammonium bromide (DEDA) in a sodium barbital buffered system at pH 8.5. The calibration curves obey Beer's Law from 0 to 40 μg/25 mL for BIDA and DISIDA, 0 to 60 μg/25 mL for DTPA and 0 to 100 μg/10 mL for MDP. (author)

  19. Interstellar material in front of chi ophiuchi. I. Optical observations

    International Nuclear Information System (INIS)

    Frisch, P.C.

    1979-01-01

    Optical observations of the interstellar material in front of chi Oph are discussed. The main interstellar cloud is made up of several regions with velocities between -6 and -12 km s -1 (heliocentric). Both CH and CH + are found within this feature, but with central velocities which differ by 2 km s -1 . Another cloud, with a velocity of -26 km s -1 , contains relatively strong Ca + lines. It has a ratio between Ca + and Na 0 column densities that is appropriate for ''high-velocity'' clouds. Calcium, iron, and sodium column densities are used to estimate an average electron density for the line of sight as well as for each cloud. The abundances of CH and CH + , and the absence of CN, are analyzed in terms of current theories about their origin

  20. Micellar modified spectrophotometric determination of nitrobenzenes based upon reduction with tin(II), diazotisation and coupling with the Bratton-Marshall reagent.

    Science.gov (United States)

    Escrig-Tena, I; Alvarez Rodríguez, L; Esteve-Romero, J; García-Alvarez-Coque, M C

    1998-09-01

    Nitrobenzenes, such as the antibiotic chloramphenicol, the vasodilator nicardipine, and the herbicides dinitramin, dinobuton, fenitrothion, methylparathion, oxyfluorfen, parathion, pendimethalin, quintozene, and trifluralin, were determined by using a spectrophotometric method in the visible region (540 nm). The method was based on the reduction of the nitrobenzenes to arylamines with tin(II) chloride, diazotisation of the arylamines and coupling of the diazonium ions with the Bratton-Marshall reagent. The two latter reactions were performed in a micellar medium of sodium dodecyl sulphate. The linear calibration range was 2x10(-6) to 7x10(-5) M (r>0.999), with limits of detection in the 10(-7) M level, which is 2-6 fold lower with respect to the corresponding spectrophotometric procedure in non-micellar medium. The procedure was applied to the analysis of the compounds in commercial preparations (pharmaceuticals and herbicide formulations) and in water samples, with good recoveries.

  1. Estimating dissolved organic carbon concentration in turbid coastal waters using optical remote sensing observations

    Science.gov (United States)

    Cherukuru, Nagur; Ford, Phillip W.; Matear, Richard J.; Oubelkheir, Kadija; Clementson, Lesley A.; Suber, Ken; Steven, Andrew D. L.

    2016-10-01

    Dissolved Organic Carbon (DOC) is an important component in the global carbon cycle. It also plays an important role in influencing the coastal ocean biogeochemical (BGC) cycles and light environment. Studies focussing on DOC dynamics in coastal waters are data constrained due to the high costs associated with in situ water sampling campaigns. Satellite optical remote sensing has the potential to provide continuous, cost-effective DOC estimates. In this study we used a bio-optics dataset collected in turbid coastal waters of Moreton Bay (MB), Australia, during 2011 to develop a remote sensing algorithm to estimate DOC. This dataset includes data from flood and non-flood conditions. In MB, DOC concentration varied over a wide range (20-520 μM C) and had a good correlation (R2 = 0.78) with absorption due to coloured dissolved organic matter (CDOM) and remote sensing reflectance. Using this data set we developed an empirical algorithm to derive DOC concentrations from the ratio of Rrs(412)/Rrs(488) and tested it with independent datasets. In this study, we demonstrate the ability to estimate DOC using remotely sensed optical observations in turbid coastal waters.

  2. Optical flare observed in the flaring gamma-ray blazar Ton 599

    Science.gov (United States)

    Pursimo, Tapio; Sagues, Ana; Telting, John; Ojha, Roopesh

    2017-11-01

    We report optical photometry of the flat spectrum radio quasar Ton 599, obtained with the 2.56m Nordic Optical Telescope in La Palma, to look for any enhanced optical activity associated with a recent flare in the daily averaged gamma-ray flux (ATel#10931, ATel#10937).

  3. New potentiometric and spectrophotometric methods for the determination of dextromethorphan in pharmaceutical preparations.

    Science.gov (United States)

    Elmosallamy, Mohamed A F; Amin, Alaa S

    2014-01-01

    New, simple and convenient potentiometric and spectrophotometric methods are described for the determination of dextromethorphan hydrobromide (DXM) in pharmaceutical preparations. The potentiometric technique is based on developing a potentiometric sensor incorporating the dextromethorphan tetrakis(p-chlorophenyl)borate ion-pair complex as an electroactive species in a plasticized PVC matrix membrane with o-nitophenyl octyl ether or dioctyl phthalate. The sensor shows a rapid near Nernstian response of over 1 × 10(-5) - 1 × 10(-2) mol L(-1) dextromethorphan in the pH range of 3.0 - 9.0. The detection limit is 2 × 10(-6) mol L(-1) DXM and the response time is instantaneous (2 s). The proposed spectrophotometric technique involves the reaction of DXM with eriochrom black T (EBT) to form an ion-associate complex. Solvent extraction is used to improve the selectivity of the method. The optimal extraction and reaction conditions have been studied, and the analytical characteristics of the method have been obtained. Linearity is obeyed in the range of 7.37 - 73.7 × 10(-5) mol L(-1) DXM, and the detection limit of the method is 1.29 × 10(-5) mol L(-1). The relative standard deviation (RSD) and relative error for six replicate measurements of 3.685 × 10(-4) mol L(-1) are 0.672 and 0.855%, respectively. The interference effect of some excepients has also been tested. The drug contents in pharmaceutical preparations were successfully determined by the proposed methods by applying the standard-addition technique.

  4. Optical observations on the CRIT-II Critical Ionization Velocity Experiment

    International Nuclear Information System (INIS)

    Stenbaek-Nielsen, H.C.; Wescott, E.M.; Haerendel, G.; Valenzuela, A.

    1990-01-01

    A rocket borne Critical Ionization Velocity (CIV) experiment was carried out from Wallops Island at dusk on May 4, 1989. Two barium shaped charges were released below the solar terminator (to prevent photoionization) at altitudes near 400 km. The ambient ionospheric electron density was 5x10 5 cm -3 . The neutral barium jet was directed upwards and at an angle of nominally 45 degrees to B which gives approximately 3x10 23 neutrals with super critical velocity. Ions created by a CIV process in the region of the neutral jet would travel up along B into sunlight where they can be detected optically. Well defined ion clouds (max. brightness 750 R) were observed in both releases. An ionization rate of 0.8%s -1 (125s ionization time constant) can account for the observed ion cloud near the release field line, but the ionization rate falls off with increasing distance from the release. It is concluded that a CIV process was present in the neutral jet out to about 50 km from the release, which is significantly further than allowed by current theories

  5. Optical Coherence Tomography Observation of Gonio Structures during Microhook Ab Interno Trabeculotomy

    Directory of Open Access Journals (Sweden)

    Masaki Tanito

    2017-01-01

    Full Text Available Introduction. Intraoperative observation of ocular structures using microscope-integrated optical coherence tomography (iOCT has been adopted recently. I report my initial feasibility assessment of iOCT for the incised trabecular meshwork observation during microhook ab interno trabeculotomy. Case Series. Both the nasal and temporal sides or either side of the trabecular meshwork/inner wall of Schlemm’s canal was incised more than 3 clock hours. After then, under observation using a Swan-Jacob gonioprism lens with the real-time 5-line scan mode, OCT images of the area were successfully acquired in 10 (83% of 12 sides in nine eyes. Based on the appearance of the acquired images of the 10 sides, the trabeculotomy cleft could be classified into three incisional patterns, that is, six (60% anterior-opening patterns (posterior-based flap, three (30% middle-opening patterns (posterior- and anterior-based flaps, and one (10% posterior-opening pattern (anterior-based flap, according to the predominant locations of the trabecular meshwork flaps. Conclusion. Intraoperative observation of the gonio structures including the trabeculotomy cleft was feasible using the RESCAN 700 in combination with a gonioprism.

  6. SU-F-T-166: On the Nature of the Background Visible Light Observed in Fiber Optic Dosimetry of Proton Beams

    Energy Technology Data Exchange (ETDEWEB)

    Darafsheh, A; Kassaee, A; Finlay, J [University of Pennsylvania, Philadelphia, PA (United States); Taleei, R [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: The nature of the background visible light observed during fiber optic dosimetry of proton beams, whether it is due to Cherenkov radiation or not, has been debated in the literature recently. In this work, experimentally and by means of Monte Carlo simulations, we shed light on this problem and investigated the nature of the background visible light observed in fiber optics irradiated with proton beams. Methods: A bare silica fiber optics was embedded in tissue-mimicking phantoms and irradiated with clinical proton beams with energies of 100–225 MeV at Roberts Proton Therapy Center. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze in detail the emission spectrum of the fiber tip across the visible range of 400–700 nm. Monte Carlo simulation was performed by using FLUKA Monte Carlo code to simulate Cherenkov light and ionizing radiation dose deposition in the fiber. Results: The experimental spectra of the irradiated silica fiber shows two distinct peaks at 450 and 650 nm, whose spectral shape is different from that of Cherenkov radiation. We believe that the nature of these peaks are connected to the point defects of silica including oxygen-deficiency center (ODC) and non-bridging oxygen hole center (NBOHC). Monte Carlo simulations confirmed the experimental observations that Cherenkov radiation cannot be solely responsible for such a signal. Conclusion: We showed that Cherenkov radiation is not the dominant visible signal observed in bare fiber optics irradiated with proton beams. We observed two distinct peaks at 450 and 650 nm whose nature is connected with the point defects of silica fiber including oxygen-deficiency center and non-bridging oxygen hole center.

  7. SPECTROPHOTOMETRIC DETERMINATION OF ACETYLCYSTEINE IN PHARMACEUTICAL FORMULATIONS USING 2,3-DICHLORO-1,4-NAPTHOQUINONE

    Directory of Open Access Journals (Sweden)

    A. O. Donchenko

    2015-04-01

    Full Text Available The aim of research was the development and validation ofspectrophotometric method foracetylcysteine assay in pharmaceutical formulations.Тhe proposed method is based on the reaction with 2,3-dichloro-1,4-naphthoquinone and the formation of colored products that exhibit absorption maxima at 425 nm. Introduction Many analytical methods have been published for acetylcysteine assay in pharmaceutical formulations as high-performance liquid chromatography (HPLC, fluorimetry and chemiluminescence. Some of these methods are time consuming or require expensive equipment. Other published methods suffer from lack of selectivity and sensitivity. Spectrophotometry is the most widely used technique in pharmaceutical analysis because it is simple, economic, and easily available to most quality control laboratories. In the present work, we propose a simple and accurate spectrophotometric method for acetylcysteine assay in pharmaceutical formulations. Materials and Methods Reagents: Reference standard acetylcysteinesubstance; 2,3-dichloro-1,4-naphthoquinone. All chemicals and solvents were of analytical grade. DMFA was used as a solvent. Pharmaceutical preparations:powder for oral solution «ACC 200» 200 mgseries number50026151 (Salutas Pharma CmbH, Germany; effervescent tablets «Fluimucil» 600 mg (Zambon S.P.A., Italy and «ACC LONG» 600 mg (Salutas Pharma CmbH, Germany series numbers 321284 and DH2740; solution for injections «Fluimucil» 100 mg/ml (Zambon S.P.A., Italyseries number28002492. Solutions: Acetylcysteine stock solution (0,16%; DMFAsolution of 2,3-dichloro-1,4-naphthoquinone (4%. Equipment Analytical balance (ABT-120-5DM; UV-VIS spectrophotometer (Specord 200; water bath (MemmertWNB 7-45;quartz cells. Results Acetylcysteine was determined using a spectrophotometric method based on the reaction with 2,3-dichloro-1,4-naphthoquinone to form yellow colored reaction products with absorption maxima at 425 nm. The effect of reaction time and

  8. Spectrophotometric determination of Tl carrier in 201Tl-TlCl injection

    International Nuclear Information System (INIS)

    Gong Quansheng; Jing Lie

    1997-01-01

    A simple and sensitive method for the spectrophotometric determination of carrier content (Thallium) in 201 Tl-TlCl injection is described. Thallium (I) is oxidised to Thallium (III) by aqueous bromine, then excess bromine is removed by adding sulfosalicylic acid. In buffer solution (NH 4 Cl-NH 4 OH) at pH 11.7 with the presence of emulsifier OP, thallium (III) and cadion form a complex having an absorption maximum at 469 nm with a molar absorptivity of 1.37 x 10 4 m 2 /mol. Beer's law is obeyed in the concentration range of 0-7 μg/5 mL. The effect of impurity elements in 201 Tl-TlCl injection is examined. It is an ideal method for the analysis of radioactive solution

  9. Development of microwave assisted spectrophotometric method for the determination of glucose

    Science.gov (United States)

    Ali, Asif; Hussain, Zahid; Arain, Muhammad Balal; Shah, Nasrullah; Khan, Khalid Mohammad; Gulab, Hussain; Zada, Amir

    2016-01-01

    A spectrophotometric method was developed based on the microwave assisted synthesis of Maillard product. Various conditions of the reaction were optimized by varying the relative concentration of the reagents, operating temperature and volume of solutions used in the reaction in the microwave synthesizer. The absorbance of the microwave synthesized Maillard product was measured in the range of 360-740 nm using UV-Visible spectrophotometer. Based on the maximum absorbance, 370 nm was selected as the optimum wave length for further studies. The LOD and LOQ of glucose was found 3.08 μg mL- 1 and 9.33 μg mL- 1 with standard deviation of ± 0.05. The developed method was also applicable to urine sample.

  10. Optical observations of Magnetosphere-Ionosphere coupling: Inter-hemispheric electron reflections within pulsating aurora

    Science.gov (United States)

    Samara, M.; Michell, R.; Khazanov, G. V.; Grubbs, G. A., II

    2017-12-01

    Magnetosphere-Ionosphere coupling is exhibited in reflected primary and secondary electrons which constitute the second step in the formation of the total precipitating electron distribution. While they have largely been missing from the current theoretical studies of particle precipitation, ground based observations point to the existence of a reflected electron population. We present evidence that pulsating aurora is caused by electrons bouncing back and forth between the two hemispheres. This means that these electrons are responsible for some of the total light in the aurora, a possibility that has largely been ignored in theoretical models. Pulsating auroral events imaged optically at high time resolution present direct observational evidence in agreement with the inter-hemispheric electron bouncing predicted by the SuperThermal Electron Trans-port (STET) model. Immediately following each of the `pulsation-on' times are equally spaced, and subsequently fainter pulsations, which can be explained by the primary precipitating electrons reflecting upwards from the ionosphere, traveling to the opposite hemisphere, and reflecting upwards again. The high time-resolution of these data, combined with the short duration of the `pulsation-on' time ( 1 s) and the relatively long spacing between pulsations ( 6 to 9 s) made it possible to observe the faint optical pulses caused by the reflected electrons coming from the opposite hemisphere. These results are significant and have broad implications because they highlight that the formation of the auroral electron distributions within regions of diffuse and pulsating aurora contain contributions from reflected primary and secondary electrons. These processes can ultimately lead to larger fluxes than expected when considering only the primary injection of magnetospheric electrons.

  11. Optical Observing Conditions at Delingha Station

    Science.gov (United States)

    Tian, J. F.; Deng, L. C.; Zhang, X. B.; Lu, X. M.; Sun, J. J.; Liu, Q. L.; Zhou, Q.; Yan, Z. Z.; Xin, Y.; Wang, K.; Jiang, X. J.; Luo, Z. Q.; Yang, J.

    2016-10-01

    SONG is a global ground-based network of 1m telescopes for stellar time-domain science, an international collaboration involving many countries across the world. In order to enable a favorable duty cycle, the SONG network plans to create a homogeneous distribution of four nodes in each of the northern and southern hemispheres. An expected possibility was building one of the northern nodes in East Asia, preferably on the Qinghai-Tibetan Plateau. During the last decade, a great deal of effort has been invested in searching for a high-quality site for ground-based astronomy in China, since this has been one of the major concerns for the development of Chinese astronomy. A number of sites on the plateau have been in operation for many years, but most of them are used only for radio astronomy, as well as small optical telescopes that are used for applied astronomy. Several potential sites for large optical instruments have been identified by the plateau site survey, but so far none of them have been adequately quantitatively characterized. Here we present results from a detailed multi-year study of the Delingha site, which was eventually selected for the SONG-China node. We also describe the site-monitoring system that will allow an isolated SONG and 50BiN node to operate safely in an automated mode.

  12. Observation of Biological Tissues Using Common Path Optical Coherence Tomography with Gold Coated Conical Tip Lens Fiber

    International Nuclear Information System (INIS)

    Taguchi, K; Sugiyama, J; Totsuka, M; Imanaka, S

    2012-01-01

    In this paper, we proposed a high lateral resolution common-path Fourier domain optical coherence tomography(OCT) system with the use of a chemically etched single mode fiber. In our experiments, single mode optical fiber for 1310nm was used for preparing the tapered tips. Our system used a conical microlens that was chemically etched by selective chemical etching technique using an etching solution of buffered hydrofluoric acid (BHF). From experimental results, we verified that our proposed optical coherence tomography system could operate as a common-path Fourier domain OCT system and conical tip lens fiber was very useful for a high lateral resolution common-path Fourier domain OCT system. Furthermore, we could observe a surface of paramecium bursaria and symbiotic chlorella in the paramecium bursaria using gold coated conical-tip fiber in the water.

  13. Influence of gamma ray irradiation and annealing temperature on the optical constants and spectral dispersion parameters of metal-free and zinc tetraphenylporphyrin thin films: A comparative study.

    Science.gov (United States)

    Zeyada, H M; Makhlouf, M M; El-Nahass, M M

    2015-09-05

    In this work, we report on the effect of γ-ray irradiation and annealing temperature on the optical properties of metal-free tetraphenylporphyrin, H2TPP, and zinc tetraphenylporphyrin, ZnTPP, thin films. Thin films of H2TPP and ZnTPP were successfully prepared by the thermal evaporation technique. The optical properties of H2TPP and ZnTPP films were investigated using spectrophotometric measurements of the transmittance and reflectance at normal incidence of light in the wavelength range from 200 to 2500 nm. The absorption spectra of H2TPP showed four absorption bands, namely the Q, B, N and M bands. The effect of inserting Zn atom into the cavity of porphyrin macrocycle in ZnTPP molecule distorted the Q and B bands, reduced the width of absorption region and influenced the optical constants and dispersion parameters. In all conditions, the type of electron transition is indirect allowed transition. Anomalous dispersion is observed in the absorption region but normal dispersion occurs in the transparent region of spectra. We adopted multi-oscillator model and the single oscillator model to interpret the anomalous and normal dispersion, respectively. We have found that the annealing temperature has mostly the opposite effect of γ-ray irradiation on absorption and dispersion characteristics of these films. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. StreakDet data processing and analysis pipeline for space debris optical observations

    Science.gov (United States)

    Virtanen, Jenni; Flohrer, Tim; Muinonen, Karri; Granvik, Mikael; Torppa, Johanna; Poikonen, Jonne; Lehti, Jussi; Santti, Tero; Komulainen, Tuomo; Naranen, Jyri

    We describe a novel data processing and analysis pipeline for optical observations of space debris. The monitoring of space object populations requires reliable acquisition of observational data, to support the development and validation of space debris environment models, the build-up and maintenance of a catalogue of orbital elements. In addition, data is needed for the assessment of conjunction events and for the support of contingency situations or launches. The currently available, mature image processing algorithms for detection and astrometric reduction of optical data cover objects that cross the sensor field-of-view comparably slowly, and within a rather narrow, predefined range of angular velocities. By applying specific tracking techniques, the objects appear point-like or as short trails in the exposures. However, the general survey scenario is always a “track before detect” problem, resulting in streaks, i.e., object trails of arbitrary lengths, in the images. The scope of the ESA-funded StreakDet (Streak detection and astrometric reduction) project is to investigate solutions for detecting and reducing streaks from optical images, particularly in the low signal-to-noise ratio (SNR) domain, where algorithms are not readily available yet. For long streaks, the challenge is to extract precise position information and related registered epochs with sufficient precision. Although some considerations for low-SNR processing of streak-like features are available in the current image processing and computer vision literature, there is a need to discuss and compare these approaches for space debris analysis, in order to develop and evaluate prototype implementations. In the StreakDet project, we develop algorithms applicable to single images (as compared to consecutive frames of the same field) obtained with any observing scenario, including space-based surveys and both low- and high-altitude populations. The proposed processing pipeline starts from the

  15. Spectrophotometric Determination of Aminoglycoside Antibiotics Based on their Oxidation by Potassium Permanganate

    International Nuclear Information System (INIS)

    El-Didamony, A. M.; Ghoneim, A. K.; Telebany, A. M.; Amin, A. S.

    2006-01-01

    A rapid, simple and sensitive validated spectrophotometric methods have been described for the assay of neomycin and streptomycin either in pure form or in pharmaceutical formulations. The proposed methods were based on the oxidation of the studied drugs by a known excess of potassium permanganate in acidic medium and estimating the unreacted permanganate with amaranth dye (method A), acid orange II (method B), indigocarmine (method C), and methylene blue (method D), in the same acid medium at a suitable λ max =521, 485, 610 and 664 nm, respectively. Beer's law is obeyed in the concentration range of 5-10 and 2-7 mg mL -1 for neomycin and streptomycin, respectively. The apparent molar absorptivity and sandell sensitivity values are in the range 5.47-6.20x10 4 , 2.35-2.91x10 5 L mol -1 cm -1 and 7.57-8.59, 5.01-6.2 ng cm -2 for neomycin and streptomycin, respectively. Different variables affecting the reaction were studied and optimized. The proposed methods were applied successfully to the determination of the examined drugs either in a pure or pharmaceutical dosage forms with good accuracy and precision. No interferences were observed from excipients and the results obtained were in good agreement with those obtained using the official methods

  16. Spectrophotometric intracutaneous analysis for differential diagnosis of pigmented skin lesions

    Directory of Open Access Journals (Sweden)

    Е. V. Filonenko

    2013-01-01

    Full Text Available The non-invasive diagnosis of pigmented skin lesions by spectrophotometric intracutaneous analysis (SIA-scopy using device for dermatoscopy (SIAscope V by Astron Clinica, Ltd was approved in P.A.Herzen Moscow Cancer Research Institute. The method is based on analysis of light interaction with wavelength of 440–960 nm anf human skin, which is recorded by change of image on scan. The comparative analysis of SIA-scopy and histological data in 327 pigmented skin lesions in 147 patients showed, that SIA had high diagnostic efficiency for cutaneous melanoma: the sensitivity was 96%, specifity – 94%, diagnostic accuracy – 94%. For study of malignant potential of pigmented lesions by SIA-scopy the most informative capacity was obtained for assessment of melanin in papillary dermis, status of blood vessels and collagen fibres (SIA-scans 3, 4, 5.

  17. Spectrophotometric, potentiometric, and gravimetric determination of lanthanides with peri-dihydroxynaphthindenone

    International Nuclear Information System (INIS)

    Hassan, S.S.M.; Mahmoud, W.H.

    1982-01-01

    Sensitive and reasonably selective methods are described for the spectrophotometric, potentiometric, and gravimetric determination of lanthanides using peri-dihydroxynaphthindenone as a novel chromogenic and precipitating reagent. The reagent forms a stable 1:2 (metal:reagent) type of complex with light lanthanides at pH 2-7 in 1:1 ethanol-water mixture. Low metal concentrations ( 4 L mol -1 cm -1 ) which obey Beer's law. Quantitative precipitation of the complexes from metal solutions of concentrations > 100 μg/mL permits both gravimetric quantitation by igniting the precipitates to the metal oxides and potentiometric titration of the excess reagent. Results with an average recovery of 98% (standard deviation 0.7%) are obtainable for 0.1 μg to 200 mg of all light lanthanides. Many foreign ions naturally occurring or frequently associated with lanthanides do not interfere or can be tolerated

  18. Spectrophotometric Modeling of MAHLI Goniometer Observations

    Science.gov (United States)

    Liang, W.; Johnson, J. R.; Hayes, A.; Lemmon, M. T.; Bell, J. F., III; Grundy, W. M.; Deen, R. G.

    2017-12-01

    The Mars Hand Lends Imager (MAHLI) on the Curiosity rover's robotic arm was used as a goniometer to acquire a multiple-viewpoint data set on sol 544 [1]. Images were acquired at 20 arm positions, all centered at the same location and from a near-constant distance of 1.0 m from the surface. Although this sequence was acquired at only one time of day ( 13:30 LTST), it provided phase angle coverage from 0-110°. Images were converted to radiance from calibrated PDS files (DRXX) using radiance scaling factors and MAHLI focus position counts in an algorithm that rescaled the data to match the Mastcam M-34 calibration via comparison of sky images acquired during the mission. Converted MAHLI radiance values from an image of the Mastcam calibration target compared favorably in the red, green, and blue Bayer filters to M-34 radiance values from an image of the same target taken minutes afterwards. The 20 MAHLI images allowed construction of a digital terrain model (DTM), although images with shadows cast by the rover arm were more challenging to include. Their current absence restricts the lowest phase angles available to about 17°. The DTM enables calculation of surface normals that can be used with sky models to correct for diffuse reflectance on surface facets prior to Hapke modeling [cf. 2-6]. Regions of interest (ROIs) were extracted using one of the low emission-angle images as a template. ROI unit types included soils, light-toned surfaces (5 cm felsic rock "Nita"), dark-toned rocks with variable textures and dust cover, and larger areas representative of the average surface (see attached figure). These ROIs were translated from the template image to the other images through a matching of DTM three-dimensional coordinates. Preliminary phase curves (prior to atmospheric correction) show that soil-dominated surfaces are most backscattering, whereas rocks are least backscattering, and light-toned surfaces exhibit wavelength-dependent scattering. Future work will include all images in the DTM and incorporate sky models to correct for diffuse skylight. [1] Johnson, J., et al. 8th Int. Conf. Mars, #1073, 2014; [2] Johnson, J., et al., LPSC, #1424, 2015; [3] Johnson, J., et al., AGU, #P43B-2125 2015; [4] Johnson, J., et al., JGR, 111, E02S14, 2006; [5] Johnson, J., JGR, 111, E12S16, 2006; [6] Johnson,J. et al., Icarus, 248, 25-71, 2015.

  19. SS433: the second Wolf-Rayet X-ray binary ?

    OpenAIRE

    Fuchs, Yael; Koch-Miramond, Lydie; Abraham, Peter

    2002-01-01

    We present mid-infrared spectrophotometric observations of SS433 with ISOPHOT. The HeI+HeII lines in both spectra of SS433 and of the Wolf-Rayet star WR147, a wind-colliding WN8+BO5 binary system, closely match. The 2.5-12 micron continuum radiation is due to an expanding wind free-free emission in an intermediate case between optically thick and optically thin regimes. The inferred mass loss rate evaluation gives ~10^{-4} Msun/yr. Our results are consistent with a Wolf-Rayet-like companion t...

  20. Evaluating a novel application of optical fibre evanescent field absorbance: rapid measurement of red colour in winegrape homogenates

    Science.gov (United States)

    Lye, Peter G.; Bradbury, Ronald; Lamb, David W.

    Silica optical fibres were used to measure colour (mg anthocyanin/g fresh berry weight) in samples of red wine grape homogenates via optical Fibre Evanescent Field Absorbance (FEFA). Colour measurements from 126 samples of grape homogenate were compared against the standard industry spectrophotometric reference method that involves chemical extraction and subsequent optical absorption measurements of clarified samples at 520 nm. FEFA absorbance on homogenates at 520 nm (FEFA520h) was correlated with the industry reference method measurements of colour (R2 = 0.46, n = 126). Using a simple regression equation colour could be predicted with a standard error of cross-validation (SECV) of 0.21 mg/g, with a range of 0.6 to 2.2 mg anthocyanin/g and a standard deviation of 0.33 mg/g. With a Ratio of Performance Deviation (RPD) of 1.6, the technique when utilizing only a single detection wavelength, is not robust enough to apply in a diagnostic sense, however the results do demonstrate the potential of the FEFA method as a fast and low-cost assay of colour in homogenized samples.

  1. Semi-empirical spectrophotometric (SESp) method for the indirect determination of the ratio of cationic micellar binding constants of counterions X⁻ and Br⁻(K(X)/K(Br)).

    Science.gov (United States)

    Khan, Mohammad Niyaz; Yusof, Nor Saadah Mohd; Razak, Norazizah Abdul

    2013-01-01

    The semi-empirical spectrophotometric (SESp) method, for the indirect determination of ion exchange constants (K(X)(Br)) of ion exchange processes occurring between counterions (X⁻ and Br⁻) at the cationic micellar surface, is described in this article. The method uses an anionic spectrophotometric probe molecule, N-(2-methoxyphenyl)phthalamate ion (1⁻), which measures the effects of varying concentrations of inert inorganic or organic salt (Na(v)X, v = 1, 2) on absorbance, (A(ob)) at 310 nm, of samples containing constant concentrations of 1⁻, NaOH and cationic micelles. The observed data fit satisfactorily to an empirical equation which gives the values of two empirical constants. These empirical constants lead to the determination of K(X)(Br) (= K(X)/K(Br) with K(X) and K(Br) representing cationic micellar binding constants of counterions X and Br⁻). This method gives values of K(X)(Br) for both moderately hydrophobic and hydrophilic X⁻. The values of K(X)(Br), obtained by using this method, are comparable with the corresponding values of K(X)(Br), obtained by the use of semi-empirical kinetic (SEK) method, for different moderately hydrophobic X. The values of K(X)(Br) for X = Cl⁻ and 2,6-Cl₂C6H₃CO₂⁻, obtained by the use of SESp and SEK methods, are similar to those obtained by the use of other different conventional methods.

  2. Chlorine Dioxide-Iodide-Methyl Acetoacetate Oscillation Reaction Investigated by UV-Vis and Online FTIR Spectrophotometric Method

    Directory of Open Access Journals (Sweden)

    Laishun Shi

    2012-01-01

    Full Text Available In order to study the chemical oscillatory behavior and mechanism of a new chlorine dioxide-iodide ion-methyl acetoacetate reaction system, a series of experiments were done by using UV-Vis and online FTIR spectrophotometric method. The initial concentrations of methyl acetoacetate, chlorine dioxide, potassium iodide, and sulfuric acid and the pH value have great influence on the oscillation observed at wavelength of 289 nm. There is a preoscillatory or induction period, and the amplitude and the number of oscillations are associated with the initial concentration of reactants. The equations for the triiodide ion reaction rate changing with reaction time and the initial concentrations in the oscillation stage were obtained. Oscillation reaction can be accelerated by increasing temperature. The apparent activation energies in terms of the induction period and the oscillation period were 26.02 KJ/mol and 17.65 KJ/mol, respectively. The intermediates were detected by the online FTIR analysis. Based upon the experimental data in this work and in the literature, a plausible reaction mechanism was proposed for the oscillation reaction.

  3. Application of a Lithium-ion Selective Metallacrown to Extraction-Spectrophotometric Determination of Lithium in Saline Water.

    Science.gov (United States)

    Katsuta, Shoichi; Saito, Yuki; Takahashi, Suguru

    2018-01-01

    The solvent-extraction behavior of Li + and Na + with a Li + selective metallacrown, [{Ru(η 6 -3,5-dimethylanisole)(2,3-pyridinediolate)} 3 ], was investigated in the presence of organic dye anions, 3',3″,5',5″-tetrabromophenolphthalein ethyl ester ([TBPE] - ), 2,6-dichloroindophenolate, and picrate ([pic] - ). Each alkali metal ion was extracted as a 1:1:1 ternary complex of the metal ion, metallacrown, and anion. The Li + /Na + extraction selectivity is anion dependent and highest with [pic] - . Therefore, we devised an extraction-spectrophotometric determination method for Li + in saline water based on the extraction of Li + using the metallacrown and [pic] - for high selectivity and subsequent replacement of [pic] - in the extracted species with [TBPE] - for high sensitivity. When applying this to artificial seawater samples containing known concentrations of Li + , a linear relationship was observed between the absorbance at 571 nm of the organic phase and the Li + concentration in the samples. By this method, the determination of Li + at the sub-ppm level in natural seawater is possible.

  4. Determination of total antioxidant capacity by a new spectrophotometric method based on Ce(IV) reducing capacity measurement.

    Science.gov (United States)

    Ozyurt, Dilek; Demirata, Birsen; Apak, Resat

    2007-02-28

    Dietary antioxidants widely found in fruits and vegetables may serve the task of reducing oxidative damage in humans induced by free radicals and reactive oxygen species under 'oxidative stress' conditions. The aim of this work is to develop a simple, low-cost, sensitive, and diversely applicable indirect spectrophotometric method for the determination of total antioxidant capacity of several plants. The method is based on the oxidation of antioxidants with cerium(IV) sulfate in dilute sulfuric acid at room temperature. The Ce(IV) reducing capacity of the sample is measured under carefully adjusted conditions of oxidant concentration and pH such that only antioxidants and not other organic compounds would be oxidized. The spectrophotometric determination of the remaining Ce(IV) was performed after completion of reaction with antioxidants. Quercetin and gallic acid were used as standards for flavonoids and phenolic acids, respectively, and results of antioxidant measurements were reported as trolox equivalents. The developed procedure was successfully applied to the assay of total antioxidant capacity due to simple compounds such as trolox, quercetin, gallic acid, ascorbic acid, catechin, naringin, naringenin, caffeic acid, chlorogenic acid, ferulic acid, and p-coumaric acid, and due to phenolic acids and flavonoids in the arieal parts of nettle (Urtica Dioica L.). Blank correction of significantly absorbing plant extracts at 320nm could be made with the aid of spectrophotometric titration. Plant selection was made in respect to high antioxidant content, and extraction was made with water. The proposed method was reproducible, and the trolox equivalent antioxidant capacities (TEAC coefficients) of the tested antioxidant compounds were correlated to those found by reference methods such as ABTS and CUPRAC. Since the TEAC coefficients found with the proposed method of naringin-naringenin and rutin-catechin pairs were close to each other, this Ce(IV)-based assay

  5. Titrimetric and Spectrophotometric Determination of Metaprolol tartrate in Pharmaceuticals Using N-Bromosuccinimide

    Directory of Open Access Journals (Sweden)

    K. Basavaiah

    2007-01-01

    Full Text Available One titrimetric and two spectrophotometric methods are presented for the assay of metaprolol tartrate (MPT in bulk drug and in tablets. The methods employ N-bromosuccinimide (NBS as the oxidimetric reagent and two dyes, methyl orange and indigo carmine as spectrophotometric reagents. In titrimetry, an acidified solution of MPT is treated with a known excess amount of NBS and after a definite time, the unreacted oxidant is determined by iodometric back titration. Spectrophotometry involves adding a measured excess of NBS to MPT in acid medium followed by determination of residual NBS by reacting with a fixed amount of either methyl orange and measuring the absorbance at 520 nm (Method A or indigo carmine and measuring the absorbance at 610 nm (Method B. In all the methods, the amount of NBS reacted corresponds to the amount of MPT. Reaction conditions have been optimized. Titrimetry allows the determination of 1 - 12 mg of MPT and the calculations are based on a 1: 4 (MPT: NBS reaction stoichiometry. In spectrophotometry, the measured absorbance is found to increase linearly with the concentration of MPT serving as basis for quantitation. The systems obey Beer’s law for 0.5 - 4.0 μg mL-1 and 1.25 - 10.0 μg mL-1 for method A and method B, respectively. The apparent absorptivities are calculated to 1.07 × 105 be and 4.22 × 104 L mol cm-1 for method A and method B, respectively. The methods developed were applied to the assay of MPT in commercial tablet formulations, and the results were compared statistically with those of a reference method. The accuracy and reliability of the methods were further ascertained by performing recovery tests via standard-addition method.

  6. Spectrophotometrical investigation of the NGC 3359 galaxy

    International Nuclear Information System (INIS)

    Burenkov, A.N.; Khchikyan, Eh.E.; AN Armyanskoj SSR, Byurakan. Astrofizicheskaya Observatoriya)

    1986-01-01

    Results of detailed spectrophotometrical investigations of NGC 3353, carried out with 6 m telescope of SAO Academy of Sciences of the USSR are presented (dispersion approximately 65 A/mm). Four separate condensations, the brightest of which is Mark 35, are studied. In the spectrum of Mark 35 the emission lines for Hsub(α) to H 12 , HeI lambda lambda 7065, 6678, 5876, 4922, 4472, 3820 and forbidden lines [01]lambda lambdas 6300/64, [02] lambda 3727, [03] lambda lambda 5007, 4959, 4363, [Ne3] lambda 3869, [N2] lambda lambda 6584/48, [S2] lambda lambda 6717/31, [S3] lambda 6310, [Ar3] lambda 7136 are detected. In the second central condensation, called ''nucleus'', emission lines are weaker and beginning with Hsub(β) the absorption components appear which become stronger in the late members of Balmer lines. The forbidden lines in the nucleus are strong: [Ne3], [O3], [O2], [S2][N2]. The relative intensities and equivalent widths of emission lines as well as the chemical composition of Mark 35 and ''nucleus'' are estimated. Both condensations according to their physical properties look like superassociations. It has been concluded that the source of excitation are young stars. NGC 3353 is probably the net of superassociations

  7. Pulse advancement and delay in an integrated optical two-port ring-resonator circuit: direct experimental observations

    NARCIS (Netherlands)

    Uranus, H.P.; Zhuang, L.; Roeloffzen, C.G.H.; Hoekstra, Hugo

    We report experimental observations of the negative-group-velocity (v_g) phenomenon in an integrated-optical two-port ring-resonator circuit. We demonstrate that when the v_g is negative, the (main) peak of output pulse appears earlier than the peak of a reference pulse, while for a positive v_g,

  8. Structural and Optical Properties of Lead-Boro-Tellurrite Glasses Induced by Gamma-Ray

    Directory of Open Access Journals (Sweden)

    Azhar Abdul Rahman

    2013-02-01

    Full Text Available Spectrophotometric studies of lead borotellurite glasses were carried out before and after gamma irradiation exposure. The increasing peak on the TeO4 bi-pyramidal arrangement and TeO3+1 (or distorted TeO4 is due to augmentation of irradiation dose which is attributed to an increase in degree of disorder of the amorphous phase. The structures of lead tellurate contain Pb3TeO6 consisting of TeO3 trigonal pyramid connected by PbO4 tetragonal forming a three-dimensional network. The decrease of glass rigidity is due to irradiation process which is supported by the XRD diffractograms results. The decreasing values of absorption edge indicate that red shift effect occur after irradiation processes. A shift in the optical absorption edge attributed to an increase of the conjugation length. The values of optical band gap, Eopt were calculated and found to be dependent on the glass composition and radiation exposure. Generally, an increase and decrease in Urbach’s energy can be considered as being due to an increase in defects within glass network.

  9. Structural and optical properties of lead-boro-tellurrite glasses induced by gamma-ray.

    Science.gov (United States)

    Mustafa, Iskandar Shahrim; Kamari, Halimah Mohamed; Yusoff, Wan Mohd Daud Wan; Aziz, Sidek Abdul; Rahman, Azhar Abdul

    2013-02-04

    Spectrophotometric studies of lead borotellurite glasses were carried out before and after gamma irradiation exposure. The increasing peak on the TeO(4) bi-pyramidal arrangement and TeO(3+1) (or distorted TeO(4)) is due to augmentation of irradiation dose which is attributed to an increase in degree of disorder of the amorphous phase. The structures of lead tellurate contain Pb(3)TeO(6) consisting of TeO(3) trigonal pyramid connected by PbO(4) tetragonal forming a three-dimensional network. The decrease of glass rigidity is due to irradiation process which is supported by the XRD diffractograms results. The decreasing values of absorption edge indicate that red shift effect occur after irradiation processes. A shift in the optical absorption edge attributed to an increase of the conjugation length. The values of optical band gap, E(opt) were calculated and found to be dependent on the glass composition and radiation exposure. Generally, an increase and decrease in Urbach's energy can be considered as being due to an increase in defects within glass network.

  10. Indirect spectrophotometric determination of BIDA, DISIDA, DTPA and MDP in labelled compounds

    Energy Technology Data Exchange (ETDEWEB)

    Van der Walt, T.N.; Coetzee, P.P. (Rand Afrikaans Univ., Johannesburg (South Africa). Dept. of Chemistry); Fourie, P.J. (Atomic Energy Corp. of South Africa (Pty) Ltd., Pretoria (South Africa))

    1989-01-01

    N-(4-(n-butyl)acetanilide)iminodiacetic acid (BIDA), N-(2,6-diisopropylacetanilide)iminodiacetic acid (DISDA), diethylenetriaminepentaacetic acid (DTPA) and methylene diphosphonic acid (MDP) are used in labelling kits. The contents of BIDA, DISIDA or MDP of the {sup 99m}Tc-labelled compounds can be determined (indirectly) spectrophotometrically with copper, eriochrome cyanine R (ECC) and dodecyl-ethyldimethylammonium bromide (DEDA) in a sodium barbital buffered system at pH 8.5. The calibration curves obey Beer's Law from 0 to 40 {mu}g/25 mL for BIDA and DISIDA, 0 to 60 {mu}g/25 mL for DTPA and 0 to 100 {mu}g/10 mL for MDP. (author).

  11. Retrieval of Aerosol Optical Depth Above Clouds from OMI Observations: Sensitivity Analysis, Case Studies

    Science.gov (United States)

    Torres, O.; Jethva, H.; Bhartia, P. K.

    2012-01-01

    A large fraction of the atmospheric aerosol load reaching the free troposphere is frequently located above low clouds. Most commonly observed aerosols above clouds are carbonaceous particles generally associated with biomass burning and boreal forest fires, and mineral aerosols originated in arid and semi-arid regions and transported across large distances, often above clouds. Because these aerosols absorb solar radiation, their role in the radiative transfer balance of the earth atmosphere system is especially important. The generally negative (cooling) top of the atmosphere direct effect of absorbing aerosols, may turn into warming when the light-absorbing particles are located above clouds. The actual effect depends on the aerosol load and the single scattering albedo, and on the geometric cloud fraction. In spite of its potential significance, the role of aerosols above clouds is not adequately accounted for in the assessment of aerosol radiative forcing effects due to the lack of measurements. In this paper we discuss the basis of a simple technique that uses near-UV observations to simultaneously derive the optical depth of both the aerosol layer and the underlying cloud for overcast conditions. The two-parameter retrieval method described here makes use of the UV aerosol index and reflectance measurements at 388 nm. A detailed sensitivity analysis indicates that the measured radiances depend mainly on the aerosol absorption exponent and aerosol-cloud separation. The technique was applied to above-cloud aerosol events over the Southern Atlantic Ocean yielding realistic results as indicated by indirect evaluation methods. An error analysis indicates that for typical overcast cloudy conditions and aerosol loads, the aerosol optical depth can be retrieved with an accuracy of approximately 54% whereas the cloud optical depth can be derived within 17% of the true value.

  12. Development and Validation of a UV Spectrophotometric and a RP-HPLC Methods for Moexipril Hydrochloride in Pure Form and Pharmaceutical Dosage Form

    International Nuclear Information System (INIS)

    Mastiholimath, V.S.; Gupte, P.P.; Mannur, V.S.

    2012-01-01

    A simple and reliable UV spectrophotometric and high-performance liquid chromatography (HPLC) methods were developed and validated for Moexipril hydrochloride in pure form and pharmaceutical dosage form. The RP-HPLC method was developed on agilant eclipse C 18 , (150 mm x 4.6 mm, 5 μm) with a mobile phase gradient system of 60 % (methanol:acetonitrile (70:30 % v/v)) : 40 % 20 mM ammonium acetate buffer pH 4.5 (v/v) and UV spectrophotometric method was developed in phosphate buffer pH 6.8. The effluent was monitored by SPD-M20A, prominence PDA detector at 210 nm. Calibration curve was linear over the concentration range of 10-35 μg/ml and 1-9 μg/ml for RP-HPLC and UV with a regression coefficient of 0.999. For RP-HPLC method Inter-day and intra-day precision % RSD values were found to be 1.00078 % and 1.49408 % respectively. For UV method 0.73386 % to 1.44111 % for inter day 0.453864 to 1.15542 intra-day precision. Recovery of Moexipril hydrochloride was found to be in the range of 99.8538 % to 101.5614 % and 100.5297586 % to 100.6431587 % for UV and RP-HPLC respectively. The limits of detection (LOD) and quantification (LOQ) for HPLC were 0.98969 and 2.99907 μg/ml, respectively. The developed RP-HPLC and UV spectrophotometric method was successfully applied for the quantitative determination of Moexipril hydrochloride in pharmaceutical dosage. (author)

  13. Contributions te the study of methods and factors affecting the spectrophotometric determination of boron traces with carmin uranium compounds

    International Nuclear Information System (INIS)

    Fernandez Cellini, R.; Gasco Sanchez, L.

    1956-01-01

    The study of some factors affecting the spectrophotometric determination of boron traces with carmin is made; the influence of carmin from different origin, the stability of complex carmin-boric acid in relation with the sulphuric acid concentration, the interference produced by ion nitrate, and the ion uraline and light influence are discussed. (Author) 36 refs

  14. VizieR Online Data Catalog: 1H 0323+342 rest frame optical spectrum with GHAO (Leon+, 2014)

    Science.gov (United States)

    Leon Tavares, J.; Kotilainen, J.; Chavushyan, V.; Anorve, C.; Puerari, I.; Cruz-Gonzalez, I.; Patino-Alvarez, V.; Anton, S.; Carraminana, A.; Carrasco, L.; Guichard, J.; Karhunen, K.; Olguin-Iglesias, A.; Sanghvi, J.; Valdes, J.

    2017-05-01

    Within the framework of a spectrophotometric monitoring program of bright γ-ray sources (Patino-Alvarez et al. 2013, Proc. Fermi Symposium, arXiv:1303.1893), we undertook spectroscopic observations of 1H 0323+342 using the Boller & Chivens long-slit spectrograph on the 2.1 m Guillermo Haro Astrophysical Observatory (GHAO) in Sonora, Mexico. The spectra were obtained under photometric weather conditions (2012 September 17, 2013 January 9, 2013 February 7 and 11) using a slit width of 2.5 arcsec. The spectral resolution was R=15 Å and R=7 Å (FWHM) for the low-resolution and intermediate-resolution spectra, respectively. The wavelength range for the three low-resolution spectra is 3800-7100 Å, and for one intermediate-resolution spectrum the wavelength range is 4300-5900 Å. The signal-to-noise ratio (S/N) was >40 in the continuum near H{Beta}. To enable a wavelength calibration, HeAr lamp spectra were taken after each object exposure. Spectrophotometric standard stars were observed every night (at least two per night) to enable flux calibration. (1 data file).

  15. Spectrophotometric determination of nitrite based on its catalytic effect on the reaction of nuclear fast red and potassium bromate

    Directory of Open Access Journals (Sweden)

    HASSAN ZAVVAR MOUSAVI

    2009-08-01

    Full Text Available A highly selective and sensitive catalytic spectrophotometric method was developed for the determination of nitrite in water samples. The method is based on its catalytic effect on the nuclear fast red–potassium bromate redox reaction in acidic medium. The reaction was followed spectrophotometrically by measuring the change in the absorbance at 518 nm of nuclear fast red 5 min after initiation of the reaction. In this study, the experimental parameters were optimized and the effects of other cations and anions on the determination of nitrite were examined. The calibration graph was linear in the range 2.0–45 µg mL-1 of nitrite. The relative standard deviations for the determination of 15 and 30 µg mL-1 of nitrite were 3.1 and 1.75 %, respectively (n = 8. The detection limit calculated from three times the standard deviation of the blank 3Sb was 0.7 µg mL-1. The method was successfully applied to the determination of nitrite in spiked tap, natural and wastewater samples.

  16. Comparison of the acetyl bromide spectrophotometric method with other analytical lignin methods for determining lignin concentration in forage samples.

    Science.gov (United States)

    Fukushima, Romualdo S; Hatfield, Ronald D

    2004-06-16

    Present analytical methods to quantify lignin in herbaceous plants are not totally satisfactory. A spectrophotometric method, acetyl bromide soluble lignin (ABSL), has been employed to determine lignin concentration in a range of plant materials. In this work, lignin extracted with acidic dioxane was used to develop standard curves and to calculate the derived linear regression equation (slope equals absorptivity value or extinction coefficient) for determining the lignin concentration of respective cell wall samples. This procedure yielded lignin values that were different from those obtained with Klason lignin, acid detergent acid insoluble lignin, or permanganate lignin procedures. Correlations with in vitro dry matter or cell wall digestibility of samples were highest with data from the spectrophotometric technique. The ABSL method employing as standard lignin extracted with acidic dioxane has the potential to be employed as an analytical method to determine lignin concentration in a range of forage materials. It may be useful in developing a quick and easy method to predict in vitro digestibility on the basis of the total lignin content of a sample.

  17. Optical observations of the type Ic supernova 2007gr in NGC 1058

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Juncheng; Wang, Xiaofeng; Li, Junzheng [Physics Department and Tsinghua Center for Astrophysics (THCA), Tsinghua University, Beijing 100084 (China); Ganeshalingam, Mohan; Silverman, Jeffrey M.; Filippenko, Alexei V.; Li, Weidong; Chornock, Ryan; Steele, Thea, E-mail: cjc09@mails.tsinghua.edu.cn, E-mail: wang_xf@mail.tsinghua.edu.cn [Department of Astronomy, University of California, Berkeley, CA 94720-3411 (United States)

    2014-08-01

    We present extensive optical observations of the normal Type Ic supernova (SN) 2007gr, spanning from about one week before maximum light to more than one year thereafter. The optical light and color curves of SN 2007gr are very similar to those of the broad-lined Type Ic SN 2002ap, but the spectra show remarkable differences. The optical spectra of SN 2007gr are characterized by unusually narrow lines, prominent carbon lines, and slow evolution of the line velocity after maximum light. The earliest spectrum (taken at t = –8 days) shows a possible signature of helium (He I λ5876 at a velocity of ∼19,000 km s{sup –1}). Moreover, the larger intensity ratio of the [O I] λ6300 and λ6364 lines inferred from the early nebular spectra implies a lower opacity of the ejecta shortly after the explosion. These results indicate that SN 2007gr perhaps underwent a less energetic explosion of a smaller-mass Wolf-Rayet star (∼8-9 M{sub ☉}) in a binary system, as favored by an analysis of the progenitor environment through pre-explosion and post-explosion Hubble Space Telescope images. In the nebular spectra, asymmetric double-peaked profiles can be seen in the [O I] λ6300 and Mg I] λ4571 lines. We suggest that the two peaks are contributed by the blueshifted and rest-frame components. The similarity in velocity structure and the different evolution of the strength of the two components favor an aspherical explosion with the ejecta distributed in a torus or disk-like geometry, but inside the ejecta the O and Mg have different distributions.

  18. Optical observations of the type Ic supernova 2007gr in NGC 1058

    International Nuclear Information System (INIS)

    Chen, Juncheng; Wang, Xiaofeng; Li, Junzheng; Ganeshalingam, Mohan; Silverman, Jeffrey M.; Filippenko, Alexei V.; Li, Weidong; Chornock, Ryan; Steele, Thea

    2014-01-01

    We present extensive optical observations of the normal Type Ic supernova (SN) 2007gr, spanning from about one week before maximum light to more than one year thereafter. The optical light and color curves of SN 2007gr are very similar to those of the broad-lined Type Ic SN 2002ap, but the spectra show remarkable differences. The optical spectra of SN 2007gr are characterized by unusually narrow lines, prominent carbon lines, and slow evolution of the line velocity after maximum light. The earliest spectrum (taken at t = –8 days) shows a possible signature of helium (He I λ5876 at a velocity of ∼19,000 km s –1 ). Moreover, the larger intensity ratio of the [O I] λ6300 and λ6364 lines inferred from the early nebular spectra implies a lower opacity of the ejecta shortly after the explosion. These results indicate that SN 2007gr perhaps underwent a less energetic explosion of a smaller-mass Wolf-Rayet star (∼8-9 M ☉ ) in a binary system, as favored by an analysis of the progenitor environment through pre-explosion and post-explosion Hubble Space Telescope images. In the nebular spectra, asymmetric double-peaked profiles can be seen in the [O I] λ6300 and Mg I] λ4571 lines. We suggest that the two peaks are contributed by the blueshifted and rest-frame components. The similarity in velocity structure and the different evolution of the strength of the two components favor an aspherical explosion with the ejecta distributed in a torus or disk-like geometry, but inside the ejecta the O and Mg have different distributions.

  19. Evaluation of sulfate aerosol optical depths over the North Atlantic and comparison with satellite observations

    International Nuclear Information System (INIS)

    Berkowitz, C.M.; Ghan, S.J.; Benkovitz, C.M.; Wagener, R.; Nemesure, S.; Schwartz, S.E.

    1993-11-01

    It has been postulated that scattering of sunlight by aerosols can significantly reduce the amount of solar energy absorbed by the climate system. Aerosol measurement programs alone cannot provide all the information needed to evaluate the radiative forcing due to anthropogenic aerosols. Thus, comprehensive global-scale aerosol models, properly validated against surface-based and satellite measurements, are a fundamental tool for evaluating the impacts of aerosols on the planetary radiation balance. Analyzed meteorological fields from the European Centre for Medium-Range Weather Forecasts are used to drive a modified version of the PNL Global Chemistry Model, applied to the atmospheric sulfur cycle. The resulting sulfate fields are used to calculate aerosol optical depths, which in turn are compared to estimates of aerosol optical depth based on satellite observations

  20. Development of Hybrid pH sensor for long-term seawater pH monitoring.

    Science.gov (United States)

    Nakano, Y.; Egashira, T.; Miwa, T.; Kimoto, H.

    2016-02-01

    We have been developing the in situ pH sensor (Hybrid pH sensor: HpHS) for the long-term seawater pH monitoring. We are planning to provide the HpHS for researchers and environmental consultants for observation of the CCS (Carbon dioxide Capture and Storage) monitoring system, the coastal environment monitoring system (e.g. Blue Carbon) and ocean acidification. The HpHS has two types of pH sensors (i.e. potentiometric pH sensor and spectrophotometric pH sensor). The spectrophotometric pH sensor can measure pH correctly and stably, however it needs large power consumption and a lot of reagents in a long period of observation. The pH sensor used m-cresol purple (mCP) as an indicator of pH (Clayton and Byrne, 1993 and Liu et al., 2011). We can choose both coefficients before deployment. On the other hand, although the potentiometric pH sensor is low power consumption and high-speed response (within 10 seconds), drifts in the pH of the potentiometric measurements may possibly occur for a long-term observation. The HpHS can measure in situ pH correctly and stably combining advantage of both pH sensors. The HpHS consists of an aluminum pressure housing with optical cell (main unit) and an aluminum silicon-oil filled, pressure-compensated vessel containing pumps and valves (diaphragm pump and valve unit) and pressure-compensated reagents bags (pH indicator, pure water and Tris buffer or certified reference material: CRM) with an ability to resist water pressure to 3000m depth. The main unit holds system control boards, pump drivers, data storage (micro SD card), LED right source, photodiode, optical cell and pressure proof windows. The HpHS also has an aluminum pressure housing that holds a rechargeable lithium-ion battery or a lithium battery for the power supply (DC 24 V). The HpHS is correcting the value of the potentiometric pH sensor (measuring frequently) by the value of the spectrophotometric pH sensor (measuring less frequently). It is possible to calibrate in