WorldWideScience

Sample records for optical emission spectrometry

  1. New developments in glow discharge optical emission and mass spectrometry

    International Nuclear Information System (INIS)

    Hoffmann, Volker; Dorka, Roland; Wilken, Ludger; Wetzig, Klaus

    2000-01-01

    This paper describes new developments in flow discharge optical emission (GD-OES) and mass spectrometry (GD-MS) at IFW and presents corresponding new applications (analysis of microelectronic multi-layer system by radio frequency glow discharge optical emission spectrometry (RF-GD-OES) and analysis of pure iron by a new Grimm-type GD-MS source)

  2. Chemical analysis of steel by optical emission spectrometry

    International Nuclear Information System (INIS)

    Hayakawa, M.O.; Kajita, T.; Jeszensky, G.

    1981-01-01

    The development of the chemical analysis for special steels by optical emission spectrometry direct reading method with computer, at the Siderurgica N.S. Aparecida S.A. is presented. Results are presented for the low alloy steels and high speed steel. Also, the contribution of this method to the special steel preparation is commented. (Author) [pt

  3. Comparison of 15N analysis by optical emission spectrometry and mass spectrometry for clinical studies during total parenteral nutrition

    International Nuclear Information System (INIS)

    Ragon, A.; Reynier, J.P.; Guiraud, G.

    1985-01-01

    During total and stable parenteral nutrition, a branched chain amino acid enriched solution containing [ 15 N]leucine was infused into a patient to determine the fate of the nitrogen administered through this formulation. Measurements of 15 N isotopic enrichments were performed on the same biological samples (urinary urea, total plasma proteins and albumin) by optical emission spectrometry (OES) and mass spectrometry (MS) to determine if OES with its specific advantages (cost, handling maintenance) constituted even with low enrichments a useful alternative technique to MS considered as the reference method. The results show that OES constituted a very useful analytical technique to obtain reliable information in clinical metabolic studies when low 15 N enrichments must be determined. (Auth.)

  4. Multi-elemental analysis of aqueous geological samples by inductively coupled plasma-optical emission spectrometry

    Science.gov (United States)

    Todorov, Todor I.; Wolf, Ruth E.; Adams, Monique

    2014-01-01

    Typically, 27 major, minor, and trace elements are determined in natural waters, acid mine drainage, extraction fluids, and leachates of geological and environmental samples by inductively coupled plasma-optical emission spectrometry (ICP-OES). At the discretion of the analyst, additional elements may be determined after suitable method modifications and performance data are established. Samples are preserved in 1–2 percent nitric acid (HNO3) at sample collection or as soon as possible after collection. The aqueous samples are aspirated into the ICP-OES discharge, where the elemental emission signals are measured simultaneously for 27 elements. Calibration is performed with a series of matrix-matched, multi-element solution standards.

  5. Determination of Cr, Mn, Si, and Ni in carbon steels by optical emission spectrometry with spark source

    International Nuclear Information System (INIS)

    Garcia Gonzalez, M.A.; Pomares Alfonso, M.; Mora Lopez, L.

    1995-01-01

    Elemental composition of steels determines some important of his characteristic moreover it is necessary to obtain their quality certification. Analytical procedure has performed for determination of Cr, Mn, Si and Ni in carbon steels by optical emission spectrometry with spark source. reproducibility of results is 5-11 %. Exactitude has tested with results that have obtained by internationally recognised methods-

  6. Partial microwave-assisted wet digestion of animal tissue using a baby-bottle sterilizer for analyte determination by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Matos, Wladiana O.; Menezes, Eveline A.; Gonzalez, Mario H.; Costa, Leticia M.; Trevizan, Lilian C.; Nogueira, Ana Rita A.

    2009-01-01

    A procedure for partial digestion of bovine tissue is proposed using polytetrafluoroethylene (PTFE) micro-vessels inside a baby-bottle sterilizer under microwave radiation for multi-element determination by inductively coupled plasma optical emission spectrometry (ICP OES). Samples were directly weighed in laboratory-made polytetrafluoroethylene vessels. Nitric acid and hydrogen peroxide were added to the uncovered vessels, which were positioned inside the baby-bottle sterilizer, containing 500 mL of water. The hydrogen peroxide volume was fixed at 100 μL. The system was placed in a domestic microwave oven and partial digestion was carried out for the determination of Ca, Cu, Fe, Mg, Mn and Zn by inductively coupled plasma optical emission spectrometry. The single-vessel approach was used in the entire procedure, to minimize contamination in trace analysis. Better recoveries and lower residual carbon content (RCC) levels were obtained under the conditions established through a 2 4-1 fractional factorial design: 650 W microwave power, 7 min digestion time, 50 μL nitric acid and 50 mg sample mass. The digestion efficiency was ascertained according to the residual carbon content determined by inductively coupled plasma optical emission spectrometry. The accuracy of the proposed procedure was checked against two certified reference materials.

  7. X-ray fluorescence analysis and optical emission spectrometry of an roman mirror from Tomis, Romania

    International Nuclear Information System (INIS)

    Belc, M.; Bogoi, M.; Ionescu, D.; Guita, D.; Caiteanu, S.; Caiteanu, D.

    2000-01-01

    The miscellaneous population of Roman Empire, their diverse cultural tradition, their ability to assimilate the roman civilization spirits, had determined a permanent reassessment superimposed upon the roman contribution. Analysis was undertaken using optical emission spectrometry and non-destructive X-ray fluorescence. X-ray fluorescence analysis is a well-established method and is often used in archaeometry and other work dealing with valuable objects pertaining to the history of art and civilization. Roman mirror analysed has been found not to be made of speculum (a high tin bronze). (authors)

  8. The Diagnosis of Plasma Parameters in Surface Alloying Technique by Optical Emission Spectrometry

    International Nuclear Information System (INIS)

    Fu Yabo; Zhang Yuefei; Chen Qiang; Zhang Guangqiu; Gao Yuan; Wang Jianzhong; Kui Xiaoyun

    2006-01-01

    Electron density (Ne) in a glow discharge plasma for the surface alloying technique is diagnosed by optical emission spectrometry (OES). With CH 4 as the feeding gas, Ne is obtained by comparing the Hβ spectrum according to the Stark broadening effect. It is noticed that Ne varies with the working pressures (30 Pa to 70 Pa) and cathode voltages (500 V to 1000 V), respectively. Due to an abnormal glow discharge, Ne is between 1.71x10 15 /cm 3 to 6.64x10 15 /cm 3 and increases rapidly with working gas pressures and cathode voltages. The results show that OES is a useful method to measure the plasma parameters in a surface alloying glow discharge plasma

  9. Classification of Antarctic algae by applying Kohonen neural network with 14 elements determined by inductively coupled plasma optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Balbinot, L. [Departamento de Quimica Analitica-Instituto de Quimica-Unicamp, PO Box 6154, CEP: 13083-971, Campinas, SP (Brazil); Smichowski, P. [Comision Nacional de Energia Atomica, Unidad de Actividad Quimica, Centro Atomico Constituyentes, Av. Gral Paz 1499, B1650KNA, San Martin, Provincia de Buenos Aires (Argentina); Farias, S. [Comision Nacional de Energia Atomica, Unidad de Actividad Quimica, Centro Atomico Constituyentes, Av. Gral Paz 1499, B1650KNA, San Martin, Provincia de Buenos Aires (Argentina); Arruda, M.A.Z. [Departamento de Quimica Analitica-Instituto de Quimica-Unicamp, PO Box 6154, CEP: 13083-971, Campinas, SP (Brazil); Vodopivez, C. [Instituto Antartico Argentino, Cerrito 1010, C1248AAZ, Buenos Aires (Argentina); Poppi, R.J. [Departamento de Quimica Analitica-Instituto de Quimica-Unicamp, PO Box 6154, CEP: 13083-971, Campinas, SP (Brazil)]. E-mail: ronei@iqm.unicamp.br

    2005-06-30

    Optical emission spectrometers can generate results, which sometimes are not easy to interpret, mainly when the analyses involve classifications. To make simultaneous data interpretation possible, the Kohonen neural network is used to classify different Antarctic algae according to their taxonomic groups from the determination of 14 analytes. The Kohonen neural network architecture used was 5x5 neurons, thus reducing 14-dimension input data to two-dimensional space. The input data were 14 analytes (As, Co, Cu, Fe, Mn, Sr, Zn, Cd, Cr, Mo, Ni, Pb, Se, V) with their concentrations, determined by inductively coupled plasma optical emission spectrometry in 11 different species of algae. Three taxonomic groups (Rhodophyta, Phaeophyta and Cholorophyta) can be differentiated and classified through only their Cu content.

  10. Classification of Antarctic algae by applying Kohonen neural network with 14 elements determined by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Balbinot, L.; Smichowski, P.; Farias, S.; Arruda, M.A.Z.; Vodopivez, C.; Poppi, R.J.

    2005-01-01

    Optical emission spectrometers can generate results, which sometimes are not easy to interpret, mainly when the analyses involve classifications. To make simultaneous data interpretation possible, the Kohonen neural network is used to classify different Antarctic algae according to their taxonomic groups from the determination of 14 analytes. The Kohonen neural network architecture used was 5x5 neurons, thus reducing 14-dimension input data to two-dimensional space. The input data were 14 analytes (As, Co, Cu, Fe, Mn, Sr, Zn, Cd, Cr, Mo, Ni, Pb, Se, V) with their concentrations, determined by inductively coupled plasma optical emission spectrometry in 11 different species of algae. Three taxonomic groups (Rhodophyta, Phaeophyta and Cholorophyta) can be differentiated and classified through only their Cu content

  11. An improved microstrip plasma for optical emission spectrometry of gaseous species

    Energy Technology Data Exchange (ETDEWEB)

    Schermer, Susanne; Bings, Nicolas H.; Bilgic, Attila M.; Stonies, Robert; Voges, Edgar; Broekaert, Jose A.C. E-mail: jose.broekaert@chemie.uni-hamburg.de

    2003-09-26

    A modified compact 2.45 GHz microstrip plasma (MSP) operated with Ar as working gas at atmospheric pressure has been characterized and examined for its suitability for the determination of Hg as gaseous species by optical emission spectrometry. As a formerly described MSP the new device is provided on a sapphire substrate. The areas of plasma stability in terms of gas flow rates and microwave power for both MSPs with respect to plasma form and reflected power were investigated. Power levels of 5-40 W and Ar flow rates of 15-60 l/h were used. The modified MSP, which extends out of the channel in the sapphire substrate, was used for the recording of emission spectra for Hg vapor at different working conditions. Using optimized parameters a detection limit for Hg of less than 10 ng Hg/l Ar is obtained. The attainable excitation temperatures in the modified MSP at different microwave power were determined under the use of Fe as thermometric species and introducing ferrocene into the plasma. They were found to be at the order of 6000-7000 K for a power of 10-40 W and a gas flow of 15 l/h. It was shown that the modified MSP source can be combined with both a conventional monochromator with photomultiplier detection and a miniaturized spectrometer with CCD detection, whereby space-angle limitations are not stringent.

  12. Quantitative determination of total cesium in highly active liquid waste by using liquid electrode plasma optical emission spectrometry.

    Science.gov (United States)

    Do, Van-Khoai; Yamamoto, Masahiko; Taguchi, Shigeo; Takamura, Yuzuru; Surugaya, Naoki; Kuno, Takehiko

    2018-06-01

    A sensitive analytical method for determination of total cesium (Cs) in highly active liquid waste (HALW) by using modified liquid electrode plasma optical emission spectrometry (LEP-OES) is developed in this study. The instrument is modified to measure radioactive samples in a glove box. The effects of important factors, including pulsed voltage sequence and nitric acid concentration, on the emission of Cs are investigated. The limit of detection (LOD) and limit of quantification (LOQ) are 0.005 mg/L and 0.02 mg/L, respectively. The achieved LOD is one order lower than that of recently developed spectroscopic methods using liquid discharge plasma. The developed method is validated by subjecting a simulated HALW sample to inductively coupled plasma mass spectrometry (ICP-MS). The recoveries obtained from a spike-and-recovery test are 96-102%, implying good accuracy. The method is successfully applied to the quantification of Cs in a real HALW sample at the Tokai reprocessing plant in Japan. Apart from dilution and filtration of the HALW sample, no other pre-treatment process is required. The results agree well with the values obtained using gamma spectrometry. The developed method offers a reliable technique for rapid analysis of total Cs in HALW samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Direct rare earth determination by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Marin, Sergio; Cornejo, Silvia; Rojas, Jacqueline

    2003-01-01

    In the present work, the use of the inductively coupled plasma optical emission spectrometry (ICP-OES), for the sequential determination of Rare Earth elements in the metallurgical process samples is described. In the first place, the optimum parameters for the determination of the elements in study are established, like instrumental calibration, wavelengths spectral selection and interference of matrix. Next, the methodology for the digestion of solid samples (system of digestion with pressure) and the recovery of the interest elements are presented. Two material rocks as of reference Syenite SY3 are used. In order to assure the validity of the obtained data, the reference materials SY2 and SY3 were analyzed by means of two different techniques, ICP-OES and ICP-Mass, this last one was made by an international laboratory and a fusion with lithium metaborate was used with digestion method. Finally, the obtained results demonstrate that the reproducibility in the recovery of rare earth analyzed by both techniques is comparable, and that the methodology of digestion used for these elements is statistically valid (author)

  14. Characterization of direct current He-N{sub 2} mixture plasma using optical emission spectroscopy and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Flores, O.; Castillo, F.; Martinez, H. [Laboratorio de Espectroscopia, Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Apartado Postal 48-3, 62251, Cuernavaca, Morelos (Mexico); Villa, M.; Reyes, P. G. [Facultad de Ciencias, Universidad Autónoma del Estado de México, Estado de México (Mexico); Villalobos, S. [Laboratorio de Espectroscopia, Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Apartado Postal 48-3, 62251, Cuernavaca, Morelos (Mexico); Facultad de Ingeniería, Universidad Nacional Autónoma de México, México D.F. (Mexico)

    2014-05-15

    This study analyses the glow discharge of He and N{sub 2} mixture at the pressure of 2.0 Torr, power of 10 W, and flow rate of 16.5 l/min, by using optical emission spectroscopy and mass spectrometry. The emission bands were measured in the wavelength range of 200–1100 nm. The principal species observed were N{sub 2}{sup +} (B{sup 2}Σ{sup +}{sub u}→X{sup 2}Σ{sup +}{sub g}), N{sub 2} (C{sup 3}Π{sub u}→B{sup 3}Π{sub g}), and He, which are in good agreement with the results of mass spectrometry. Besides, the electron temperature and ion density were determined by using a double Langmuir probe. Results indicate that the electron temperature is in the range of 1.55–2.93 eV, and the electron concentration is of the order of 10{sup 10} cm{sup −3}. The experimental results of electron temperature and ion density for pure N{sub 2} and pure He are in good agreement with the values reported in the literature.

  15. Flame emission, atomic absorption and fluorescence spectrometry

    International Nuclear Information System (INIS)

    Horlick, G.

    1980-01-01

    Six hundred and thirty references are cited in this review. The information in the review is divided into 12 major areas: books, reviews, and bibliographies; fundamental studies in flames; developments in instrumentation; measurement techniques and procedure; flame emission spectrometry; flame atomic absorption spectrometry; flame molecular absorption spectrometry; electrothermal atomization atomic absorption spectroscopy; hydride generation techniques; graphite furnace atomic emission spectrometry; atomic fluorescence spectrometry; and analytical comparisons

  16. Time domain optical spectrometry with fiber optic waveguides

    International Nuclear Information System (INIS)

    Whitten, W.B.

    1983-01-01

    Spectrometers which use optical fibers to obtain time domain spectral dispersion are reviewed. Pulse transmission through fiber optic waveguides is discussed and the basic requirements for sources and detectors are given. Multiplex spectrometry and time-of-flight spectrometry are then discussed. Resolution, fiber requirements, instrumentation and specific spectrometers are presented

  17. Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead.

    Science.gov (United States)

    Barua, Suman; Rahman, Ismail M M; Alam, Iftakharul; Miyaguchi, Maho; Sawai, Hikaru; Maki, Teruya; Hasegawa, Hiroshi

    2017-08-15

    A relatively rapid and precise method is presented for the determination of lead in aqueous matrix. The method consists of analyte quantitation using the liquid electrode plasma-optical emission spectrometry (LEP-OES) coupled with selective separation/preconcentration by solid-phase extraction (SPE). The impact of operating variables on the retention of lead in SPEs such as pH, flow rate of the sample solution; type, volume, flow rate of the eluent; and matrix effects were investigated. Selective SPE-separation/preconcentration minimized the interfering effect due to manganese in solution and limitations in lead-detection in low-concentration samples by LEP-OES. The LEP-OES operating parameters such as the electrical conductivity of sample solution; applied voltage; on-time, off-time, pulse count for applied voltage; number of measurements; and matrix effects have also been optimized to obtain a distinct peak for the lead at λ max =405.8nm. The limit of detection (3σ) and the limit of quantification (10σ) for lead determination using the technique were found as 1.9 and 6.5ng mL -1 , respectively. The precision, as relative standard deviation, was lower than 5% at 0.1μg mL -1 Pb, and the preconcentration factor was found to be 187. The proposed method was applied to the analysis of lead contents in the natural aqueous matrix (recovery rate:>95%). The method accuracy was verified using certified reference material of wastewaters: SPS-WW1 and ERM-CA713. The results from LEP-OES were in good agreement with inductively coupled plasma optical emission spectrometry measurements of the same samples. The application of the method is rapid (≤5min, without preconcentration) with a reliable detection limit at trace levels. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Inductively coupled plasma optical emission spectrometry analysis of lanthanum, samarium and gadolinium oxides for rare earths impurities

    International Nuclear Information System (INIS)

    Reino, L.C.P.; Lordello, A.R.

    1990-09-01

    An inductively coupled plasma optical emission spectrometry method is described for the determination of Sm, Eu, La, Gd, Dy, Pr, Ho, Nd, Tb and Y in purified oxides of lanthanum, samarium and gadolinium. The method enables a simple, precise and readily available determination. Dissolution of the samples is achieved with diluted hydrochloric acid (1:1). The solutions are diluted to volume for a concentration of 1mg/ml. The lowest determination limit is 0,01% for most elements and 0,05 or 0,1% for a few rare earths in samarium and gadolinium matrices. Lanthanum, Samarium and Gadolinium concentrates with purity grade of 99,9%, 99,6% and 99,8%, respectively, can be analysed by this procedure. (author)

  19. In-situ optical emission spectrometry during galvanostatic aluminum anodising

    International Nuclear Information System (INIS)

    Mercier, D.; Van Overmeere, Q.; Santoro, R.; Proost, J.

    2011-01-01

    In this study, we report on the use of optical emission spectrometry (OES) for the online detection of changes in the Al concentration ejected in a 1.0 mol dm -3 sulphuric acid electrolyte during galvanostatic anodising of Al thin film substrates. The technique relies on the coupling of an Inductively Coupled Plasma (ICP) spectrometer to a specially designed electrochemical flow cell. This has allowed to correlate, for the first time, the kinetics of Al dissolution to well-established morphological changes related to porous anodic oxide formation and growth. A deconvolution algorithm was first developed in order to decompose the experimental ICP/OES signal into elementary distributions, each one characteristic for a specific kinetic regime. The highest dissolution rate systematically occurred during the first step, associated with barrier oxide formation. This is followed by a systematic decrease in the rate of Al dissolution during pore formation. During steady-state porous oxide growth, the Al dissolution rate increases again, but still remains below the level established during barrier oxide growth. In each of these three kinetic regimes, a linear variation of the Al dissolution rate with current density was observed in the range 0.5-5.0 mA cm -2 , with slope values of, respectively, 35 ± 2, 24 ± 2 and 28 ± 1 μg C -1 . Regarding the temporal transitions between the different regimes, a desynchronisation was observed between the kinetic (dissolution) and morphological transitions, the time offset going in opposite directions for barrier and steady-state porous oxide growth. Finally, using the measured Al dissolution rates, the current density dependence of the film formation efficiency for both porous and barrier oxide growth has been established.

  20. Determination of Micro minerals in Milk from Farm and Pasture-reared Cow, Goat and Camel; using Inductively Coupled Plasma-Optical Emission Spectrometry

    OpenAIRE

    SirelkhatimBalla Elhardallou; Ashraf Yehia El-naggar

    2016-01-01

    This study covers raw fresh milk of cow, goat and camel (farm and pasture-reared),in addition to two brands of commercial milk samples, liquid milk of powder origin and drinking yoghurt samples. Camel milk showed a relatively lower pH range (6.15 - 6.46) compared cow, goat and commercial milk. The pH of drinking yoghurt was found (4.35 - 4.47).Microwave digestion, was selected followed by mineral analysis using Inductively Coupled Plasma-Optical Emission Spectrometry. Micro minerals; Cd, Cr...

  1. Online Determination of Sm, Eu and Yb in Environmental Samples by Inductively Coupled Plasma – Optical Emission Spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dilip Kumar

    2007-01-01

    Full Text Available A procedure was developed for the determination of Sm, Eu and Yb in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES after preconcentration on synthesized 5-(4-pyridyl azo-8-quinolinol supported by Borassus flabellifer inflorescence (BFI. The sorbed element was subsequently eluted with 0.4 M HNO3 and the acid eluates were analyzed by ICP-OES. Under the optimal conditions, Sm, Eu and Yb in aqueous samples were concentrated 100-fold. Recoveries were obtained by the proposed method in the range of 98.6 -99.8%. This method was also applied for the analysis of spiked and natural water samples. The results provide strong evidence to support the hypothesis of an adsorption mechanism.

  2. Metal carbonyl vapor generation coupled with dielectric barrier discharge to avoid plasma quench for optical emission spectrometry.

    Science.gov (United States)

    Cai, Yi; Li, Shao-Hua; Dou, Shuai; Yu, Yong-Liang; Wang, Jian-Hua

    2015-01-20

    The scope of dielectric barrier discharge (DBD) microplasma as a radiation source for optical emission spectrometry (OES) is extended by nickel carbonyl vapor generation. We proved that metal carbonyl completely avoids the extinguishing of plasma, and it is much more suitable for matching the DBD excitation and OES detection with respect to significant DBD quenching by concomitant hydrogen when hydride generation is used. A concentric quartz UV reactor allows sample solution to flow through the central channel wherein to efficiently receive the uniformly distributed UV irradiation in the confined cylindrical space between the concentric tubes, which facilitates effective carbonyl generation in a nickel solution. The carbonyl is transferred into the DBD excitation chamber by an argon stream for nickel excitation, and the characteristic emission of nickel at 232.0 nm is detected by a charge-coupled device (CCD) spectrometer. A 1.0 mL sample solution results in a linear range of 5-100 μg L(-1) along with a detection limit of 1.3 μg L(-1) and a precision of 2.4% RSD at 50 μg L(-1). The present DBD-OES system is validated by nickel in certified reference materials.

  3. Reliability of graphite furnace atomic absorption spectrometry as ...

    African Journals Online (AJOL)

    spectrometry as alternative method for trace analysis of ... Purpose: To evaluate the comparative efficiency of graphite furnace atomic absorption spectrometry .... Methods comparison and validation .... plasma-optical emission spectrometry.

  4. Simultaneous determination of macronutrients, micronutrients and trace elements in mineral fertilizers by inductively coupled plasma optical emission spectrometry

    Science.gov (United States)

    de Oliveira Souza, Sidnei; da Costa, Silvânio Silvério Lopes; Santos, Dayane Melo; dos Santos Pinto, Jéssica; Garcia, Carlos Alexandre Borges; Alves, José do Patrocínio Hora; Araujo, Rennan Geovanny Oliveira

    2014-06-01

    An analytical method for simultaneous determination of macronutrients (Ca, Mg, Na and P), micronutrients (Cu, Fe, Mn and Zn) and trace elements (Al, As, Cd, Pb and V) in mineral fertilizers was optimized. Two-level full factorial design was applied to evaluate the optimal proportions of reagents used in the sample digestion on hot plate. A Doehlert design for two variables was used to evaluate the operating conditions of the inductively coupled plasma optical emission spectrometer in order to accomplish the simultaneous determination of the analyte concentrations. The limits of quantification (LOQs) ranged from 2.0 mg kg- 1 for Mn to 77.3 mg kg- 1 for P. The accuracy and precision of the proposed method were evaluated by analysis of standard reference materials (SRMs) of Western phosphate rock (NIST 694), Florida phosphate rock (NIST 120C) and Trace elements in multi-nutrient fertilizer (NIST 695), considered to be adequate for simultaneous determination. Twenty-one samples of mineral fertilizers collected in Sergipe State, Brazil, were analyzed. For all samples, the As, Ca, Cd and Pb concentrations were below the LOQ values of the analytical method. For As, Cd and Pb the obtained LOQ values were below the maximum limit allowed by the Brazilian Ministry of Agriculture, Livestock and Food Supply (Ministério da Agricultura, Pecuária e Abastecimento - MAPA). The optimized method presented good accuracy and was effectively applied to quantitative simultaneous determination of the analytes in mineral fertilizers by inductively coupled plasma optical emission spectrometry (ICP OES).

  5. Glow discharge optical emission spectroscopy for accurate and well resolved analysis of coatings and thin films

    KAUST Repository

    Wilke, Marcus; Teichert, Gerd; Gemma, Ryota; Pundt, Astrid; Kirchheim, Reiner; Romanus, Henry; Schaaf, Peter

    2011-01-01

    overview on new developments in instrument design for accurate and well resolved thin film analyses is presented. The article focuses on the analytical capabilities of glow discharge optical emission spectrometry in the analysis of metallic coatings

  6. The microwave induced plasma with optical emission spectrometry (MIP-OES) in 23 elements determination in geological samples.

    Science.gov (United States)

    Niedzielski, P; Kozak, L; Wachelka, M; Jakubowski, K; Wybieralska, J

    2015-01-01

    The article presents the optimisation, validation and application of the microwave induced plasma optical emission spectrometry (MIP-OES) dedicated for a routine determination of Ag, Al, B, Ba, Bi, Ca, Cd, Cr, Cu, Fe, Ga, In, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sr, Tl, Zn, in the geological samples. The three procedures of sample preparation has been proposed: sample digestion with the use of hydrofluoric acid for determination of total concentration of elements, extraction by aqua regia for determination of the quasi-total element concentration and extraction by hydrochloric acid solution to determine contents of the elements in acid leachable fraction. The detection limits were on the level 0.001-0.121 mg L(-1) (from 0.010-0.10 to 1.2-12 mg kg(-1) depend on the samples preparation procedure); the precision: 0.20-1.37%; accuracy 85-115% (for recovery for certified standards materials analysis and parallel analysis by independent analytical techniques: X-ray fluorescence (XRF) and flame absorption spectrometry (FAAS)). The conformity of the results obtained by MIP-OES analytical procedures with the results obtained by XRF and FAAS analysis allows to propose the procedures for studies of elemental composition of the fraction of the geological samples. Additionally, the MIP-OES technique is much less expensive than ICP techniques and much less time-consuming than AAS techniques. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Selective Iron(III ion uptake using CuO-TiO2 nanostructure by inductively coupled plasma-optical emission spectrometry

    Directory of Open Access Journals (Sweden)

    Rahman Mohammed M

    2012-12-01

    Full Text Available Abstract Background CuO-TiO2 nanosheets (NSs, a kind of nanomaterials is one of the most attracting class of transition doped semiconductor materials due to its interesting and important optical, electrical, and structural properties and has many technical applications, such as in metal ions detection, photocatalysis, Chemi-sensors, bio-sensors, solar cells and so on. In this paper the synthesis of CuO-TiO2 nanosheets by the wet-chemically technique is reported. Methods CuO-TiO2 NSs were prepared by a wet-chemical process using reducing agents in alkaline medium and characterized by UV/vis., FT-IR spectroscopy, X-ray photoelectron spectroscopy (XPS, powder X-ray diffraction (XRD, and field-emission scanning electron microscopy (FE-SEM etc. Results The structural and optical evaluation of synthesized NSs were measured by XRD pattern, Fourier transform infrared (FT-IR and UV–vis spectroscopy, respectively which confirmed that the obtained NSs are well-crystalline CuO-TiO2 and possessing good optical properties. The morphological analysis of CuO-TiO2 NSs was executed by FE-SEM, which confirmed that the doped products were sheet-shaped and growth in large quantity. Here, the analytical efficiency of the NSs was applied for a selective adsorption of iron(III ion prior to detection by inductively coupled plasma-optical emission spectrometry (ICP-OES. The selectivity of NSs towards various metal ions, including Au(III, Cd(II, Co(II, Cr(III, Fe(III, Pd(II, and Zn(II was analyzed. Conclusions Based on the selectivity study, it was confirmed that the selectivity of doped NSs phase was the most towards Fe(III ion. The static adsorption capacity for Fe(III was calculated to be 110.06 mgg−1. Results from adsorption isotherm also verified that the adsorption process was mainly monolayer-adsorption onto a surface containing a finite number of CuO-TiO2 NSs adsorption sites.

  8. Introduction of organic/hydro-organic matrices in inductively coupled plasma optical emission spectrometry and mass spectrometry: a tutorial review. Part II. Practical considerations.

    Science.gov (United States)

    Leclercq, Amélie; Nonell, Anthony; Todolí Torró, José Luis; Bresson, Carole; Vio, Laurent; Vercouter, Thomas; Chartier, Frédéric

    2015-07-23

    Inductively coupled plasma optical emission spectrometry (ICP-OES) and mass spectrometry (ICP-MS) are increasingly used to carry out analyses in organic/hydro-organic matrices. The introduction of such matrices into ICP sources is particularly challenging and can be the cause of numerous drawbacks. This tutorial review, divided in two parts, explores the rich literature related to the introduction of organic/hydro-organic matrices in ICP sources. Part I provided theoretical considerations associated with the physico-chemical properties of such matrices, in an attempt to understand the induced phenomena. Part II of this tutorial review is dedicated to more practical considerations on instrumentation, instrumental and operating parameters, as well as analytical strategies for elemental quantification in such matrices. Two important issues are addressed in this part: the first concerns the instrumentation and optimization of instrumental and operating parameters, pointing out (i) the description, benefits and drawbacks of different kinds of nebulization and desolvation devices and the impact of more specific instrumental parameters such as the injector characteristics and the material used for the cone; and, (ii) the optimization of operating parameters, for both ICP-OES and ICP-MS. Even if it is at the margin of this tutorial review, Electrothermal Vaporization and Laser Ablation will also be shortly described. The second issue is devoted to the analytical strategies for elemental quantification in such matrices, with particular insight into the isotope dilution technique, particularly used in speciation analysis by ICP-coupled separation techniques. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Direct isotope ratio measurement of uranium metal by emission spectrometry on a laser-produced plasma

    International Nuclear Information System (INIS)

    Pietsch, W.; Petit, A.; Briand, A.

    1995-01-01

    The method of Optical Emission Spectrometry on a Laser-Produced Plasma (OES/LPP) at reduced pressure has been studied for the determination of the uranium isotope ratio ( 235 U/ 238 U). Spectral profiles of the investigated transition U-II 424.437 nm show the possibility to obtain an isotopic spectral resolution in a laser-produced plasma under exactly defined experimental conditions. Spectroscopic data and results are presented. (author)

  10. On-line system for preconcentration and determination of metals in vegetables by Inductively Coupled Plasma Optical Emission Spectrometry

    International Nuclear Information System (INIS)

    Bezerra, Marcos A.; Santos, Walter N.L. dos; Lemos, Valfredo A.; Korn, Maria das Gracas A.; Ferreira, Sergio L.C.

    2007-01-01

    A procedure has been developed for the simultaneous determination of trace amounts of cadmium, copper, chromium, nickel and lead in digested vegetable samples. The method involves solid-phase extraction of the metals using a minicolumn of Amberlite XAD-4 modified with dihydroxybenzoic acid (DHB) and detection by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The elution of the metals from minicolumn was performed with 1.0 mol L -1 hydrochloric acid. Variables associated with flow preconcentration system performance, such as pH, buffer concentration, eluent concentration and sampling flow rate, were optimized. The developed procedure provides enrichment factors of 100, 72, 16, 91 and 53, for cadmium, copper, chromium, nickel and lead, respectively. Detection limits (3σ B ) were 0.02 (Cd), 0.23 (Cu), 0.58 (Cr), 0.060 (Ni) and 0.54 (Pb) μg L -1 . The procedure was applied for determination of metals in samples of guarana and cabbage. The accuracy of the method was checked by the analysis of a certified reference material (NIST 1571, Orchard leaves). Results found were in agreement with certified values

  11. On-line preconcentration and determination of chromium in parenteral solutions by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Gil, R.A.; Cerutti, S.; Gasquez, J.A.; Olsina, R.A.; Martinez, L.D.

    2005-01-01

    A method for the preconcentration and speciation of chromium was developed. On-line preconcentration and determination were obtained using inductively coupled plasma optical emission spectrometry (ICP-OES) coupled with flow injection. To determinate the chromium (III) present in parenteral solutions, chromium was retained on activated carbon at pH 5.0. On the other hand, a step of reduction was necessary in order to determine total chromium content. The Cr(VI) concentration was then determined by difference between the total chromium concentration and that of Cr(III). A sensitivity enrichment factor of 70-fold was obtained with respect to the chromium determination by ICP-OES without preconcentration. The detection limit for the preconcentration of 25 ml of sample was 29 ng l -1 . The precision for the 10 replicate determinations at the 5 μg l -1 Cr level was 2.3% relative standard deviation, calculated with the peak heights. The calibration graph using the preconcentration method for chromium species was linear with a correlation coefficient of 0.9995 at levels near the detection limits up to at least 60 μg l -1 . The method can be applied to the determination and speciation of chromium in parenteral solutions

  12. Simple, sensitive nitrogen analyzer based on pulsed miniplasma source emission spectrometry

    International Nuclear Information System (INIS)

    Jin Zhe; Duan Yixiang

    2003-01-01

    The development of pulsed miniplasma source emission spectrometry for trace nitrogen determination in inert gases is described in this article. The instrument consists of a pulsed miniplasma source generated by an in-house fabricated portable high-voltage supply, an optical beam collection system, an integrated small spectrometer with a charge-coupled-device detector, an interface card, and a notebook computer for controlling spectrometer parameters and signal processing. Trace nitrogen in the inert gases, such as helium and argon, was determined by monitoring the emission intensities from nitrogen molecules at 357 and 337 nm. The analytical performance was examined under various experimental conditions. The system has a detection limit of about 15 ppb (v/v) for nitrogen in helium with a relative standard deviation of 1.5%. The newly developed instrument offers a simple, low-cost, and sensitive method for continuously monitoring trace nitrogen in high-purity inert gases

  13. Novel Fiber-Optic Ring Acoustic Emission Sensor.

    Science.gov (United States)

    Wei, Peng; Han, Xiaole; Xia, Dong; Liu, Taolin; Lang, Hao

    2018-01-13

    Acoustic emission technology has been applied to many fields for many years. However, the conventional piezoelectric acoustic emission sensors cannot be used in extreme environments, such as those with heavy electromagnetic interference, high pressure, or strong corrosion. In this paper, a novel fiber-optic ring acoustic emission sensor is proposed. The sensor exhibits high sensitivity, anti-electromagnetic interference, and corrosion resistance. First, the principle of a novel fiber-optic ring sensor is introduced. Different from piezoelectric and other fiber acoustic emission sensors, this novel sensor includes both a sensing skeleton and a sensing fiber. Second, a heterodyne interferometric demodulating method is presented. In addition, a fiber-optic ring sensor acoustic emission system is built based on this method. Finally, fiber-optic ring acoustic emission experiments are performed. The novel fiber-optic ring sensor is glued onto the surface of an aluminum plate. The 150 kHz standard continuous sinusoidal signals and broken lead signals are successfully detected by the novel fiber-optic ring acoustic emission sensor. In addition, comparison to the piezoelectric acoustic emission sensor is performed, which shows the availability and reliability of the novel fiber-optic ring acoustic emission sensor. In the future, this novel fiber-optic ring acoustic emission sensor will provide a new route to acoustic emission detection in harsh environments.

  14. Dielectric barrier discharge micro-plasma emission spectrometry for the detection of acetone in exhaled breath.

    Science.gov (United States)

    Yang, Ting; Gao, Dong-Xue; Yu, Yong-Liang; Chen, Ming-Li; Wang, Jian-Hua

    2016-01-01

    Acetone is a predominant volatile organic compound (VOC) in the exhaled breath and a promising biomarker for diabetes and ketoacidosis. A non-thermal micro-plasma generated in a planar dielectric barrier discharge (DBD) is used as a radiation source for the excitation of gaseous acetone followed by its quantification with optical emission spectrometry (OES). Gaseous acetone can be directly sampled, while liquid acetone is evaporated by heated tungsten coil and then introduced into the DBD micro-plasma by a helium carrier flow for performing optical emission and detection at a 519 nm emission line. In the present study, the exhaled breath is collected and transferred into aqueous medium for sampling. With a sampling volume of 7 μL in a micro-drop, a linear range of 40-1600 mg L(-1) is obtained along with a detection limit of 44 ng and a precision of 5.7% RSD. The present system is successfully applied to the determination of breath acetone for both diabetic patients and healthy volunteers. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Novel Fiber-Optic Ring Acoustic Emission Sensor

    Directory of Open Access Journals (Sweden)

    Peng Wei

    2018-01-01

    Full Text Available Acoustic emission technology has been applied to many fields for many years. However, the conventional piezoelectric acoustic emission sensors cannot be used in extreme environments, such as those with heavy electromagnetic interference, high pressure, or strong corrosion. In this paper, a novel fiber-optic ring acoustic emission sensor is proposed. The sensor exhibits high sensitivity, anti-electromagnetic interference, and corrosion resistance. First, the principle of a novel fiber-optic ring sensor is introduced. Different from piezoelectric and other fiber acoustic emission sensors, this novel sensor includes both a sensing skeleton and a sensing fiber. Second, a heterodyne interferometric demodulating method is presented. In addition, a fiber-optic ring sensor acoustic emission system is built based on this method. Finally, fiber-optic ring acoustic emission experiments are performed. The novel fiber-optic ring sensor is glued onto the surface of an aluminum plate. The 150 kHz standard continuous sinusoidal signals and broken lead signals are successfully detected by the novel fiber-optic ring acoustic emission sensor. In addition, comparison to the piezoelectric acoustic emission sensor is performed, which shows the availability and reliability of the novel fiber-optic ring acoustic emission sensor. In the future, this novel fiber-optic ring acoustic emission sensor will provide a new route to acoustic emission detection in harsh environments.

  16. Tin Content Determination in Canned Fruits and Vegetables by Hydride Generation Inductively Coupled Plasma Optical Emission Spectrometry

    Directory of Open Access Journals (Sweden)

    Sanda Rončević

    2012-01-01

    Full Text Available Tin content in samples of canned fruits and vegetables was determined by hydride generation inductively coupled plasma atomic emission spectrometry (HG-ICP-OES, and it was compared with results obtained by standard method of flame atomic absorption spectrometry (AAS. Selected tin emission lines intensity was measured in prepared samples after addition of tartaric acid and followed by hydride generation with sodium borohydride solution. The most favorable line at 189.991 nm showed the best detection limit (1.9 μg L−1 and limit of quantification (6.4 μg kg−1. Good linearity and sensitivity were established from time resolved analysis and calibration tests. Analytical accuracy of 98–102% was obtained by recovery study of spiked samples. Method of standard addition was applied for tin determination in samples from fully protected tinplate. Tin presence at low-concentration range was successfully determined. It was shown that tenth times less concentrations of Sn were present in protected cans than in nonprotected or partially protected tinplate.

  17. Possibilities of High Resolution Inductively Coupled Plasma Optical Emission Spectrometry in the Determination of Trace Elements in Environmental Materials

    Directory of Open Access Journals (Sweden)

    Nikolaya Velitchkova

    2013-01-01

    Full Text Available This paper presents new quantitative data for the spectral interferences obtained by high resolution 40.68 MHz radial viewing inductively coupled plasma optical emission spectrometry (HR-ICP-OES in the determination of Zn, Cd, Sb, Cu, Mn, Pb, Sn, Cr, U, and Ba in environmental materials in the presence of a complex matrix, containing Al, Ca, Fe, Mg, and Ti. The -concept for quantification of spectral interferences was used. The optimum line selection for trace analysis of a variety of multicomponent matrices requires the choice of prominent lines, which are free or negligibly influenced by line interference problems. The versatility of -concept as basic methodology was experimentally demonstrated in the determination of trace of elements in soil and drinking water. The detection limits are lower in comparison with corresponding threshold concentration levels for soil and drinking water in accordance with environmental regulations. This paper shows the possibilities of present day ICP-OES equipment in the direct determination of trace elements (without preconcentration of impurities in environmental samples.

  18. Simultaneous determination of macronutrients, micronutrients and trace elements in mineral fertilizers by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Oliveira Souza, Sidnei de; Silvério Lopes da Costa, Silvânio; Santos, Dayane Melo; Santos Pinto, Jéssica dos; Garcia, Carlos Alexandre Borges

    2014-01-01

    An analytical method for simultaneous determination of macronutrients (Ca, Mg, Na and P), micronutrients (Cu, Fe, Mn and Zn) and trace elements (Al, As, Cd, Pb and V) in mineral fertilizers was optimized. Two-level full factorial design was applied to evaluate the optimal proportions of reagents used in the sample digestion on hot plate. A Doehlert design for two variables was used to evaluate the operating conditions of the inductively coupled plasma optical emission spectrometer in order to accomplish the simultaneous determination of the analyte concentrations. The limits of quantification (LOQs) ranged from 2.0 mg kg −1 for Mn to 77.3 mg kg −1 for P. The accuracy and precision of the proposed method were evaluated by analysis of standard reference materials (SRMs) of Western phosphate rock (NIST 694), Florida phosphate rock (NIST 120C) and Trace elements in multi-nutrient fertilizer (NIST 695), considered to be adequate for simultaneous determination. Twenty-one samples of mineral fertilizers collected in Sergipe State, Brazil, were analyzed. For all samples, the As, Ca, Cd and Pb concentrations were below the LOQ values of the analytical method. For As, Cd and Pb the obtained LOQ values were below the maximum limit allowed by the Brazilian Ministry of Agriculture, Livestock and Food Supply (Ministério da Agricultura, Pecuária e Abastecimento — MAPA). The optimized method presented good accuracy and was effectively applied to quantitative simultaneous determination of the analytes in mineral fertilizers by inductively coupled plasma optical emission spectrometry (ICP OES). - Highlights: • Determination of inorganic constituents in mineral fertilizers was proposed. • Experimental design methodology was used to optimize analytical method. • The sample preparation procedure using diluted reagents (HNO 3 and H 2 O 2 ) was employed. • The analytical method was satisfactorily to the determination of thirteen elements. • The ICP OES technique can be

  19. Simultaneous determination of macronutrients, micronutrients and trace elements in mineral fertilizers by inductively coupled plasma optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Souza, Sidnei de [Laboratório de Química Analítica Ambiental (LQA), Departamento de Química, Centro de Ciências Exatas e Tecnologia, Universidade Federal de Sergipe (UFS), 49100-000, São Cristovão, SE (Brazil); Silvério Lopes da Costa, Silvânio [Laboratório de Química Analítica Ambiental (LQA), Departamento de Química, Centro de Ciências Exatas e Tecnologia, Universidade Federal de Sergipe (UFS), 49100-000, São Cristovão, SE (Brazil); Coordenação de Química, Universidade Federal de Alagoas (UFAL), Campus Arapiraca, 57309-005, Arapiraca, AL (Brazil); Santos, Dayane Melo; Santos Pinto, Jéssica dos; Garcia, Carlos Alexandre Borges [Laboratório de Química Analítica Ambiental (LQA), Departamento de Química, Centro de Ciências Exatas e Tecnologia, Universidade Federal de Sergipe (UFS), 49100-000, São Cristovão, SE (Brazil); and others

    2014-06-01

    An analytical method for simultaneous determination of macronutrients (Ca, Mg, Na and P), micronutrients (Cu, Fe, Mn and Zn) and trace elements (Al, As, Cd, Pb and V) in mineral fertilizers was optimized. Two-level full factorial design was applied to evaluate the optimal proportions of reagents used in the sample digestion on hot plate. A Doehlert design for two variables was used to evaluate the operating conditions of the inductively coupled plasma optical emission spectrometer in order to accomplish the simultaneous determination of the analyte concentrations. The limits of quantification (LOQs) ranged from 2.0 mg kg{sup −1} for Mn to 77.3 mg kg{sup −1} for P. The accuracy and precision of the proposed method were evaluated by analysis of standard reference materials (SRMs) of Western phosphate rock (NIST 694), Florida phosphate rock (NIST 120C) and Trace elements in multi-nutrient fertilizer (NIST 695), considered to be adequate for simultaneous determination. Twenty-one samples of mineral fertilizers collected in Sergipe State, Brazil, were analyzed. For all samples, the As, Ca, Cd and Pb concentrations were below the LOQ values of the analytical method. For As, Cd and Pb the obtained LOQ values were below the maximum limit allowed by the Brazilian Ministry of Agriculture, Livestock and Food Supply (Ministério da Agricultura, Pecuária e Abastecimento — MAPA). The optimized method presented good accuracy and was effectively applied to quantitative simultaneous determination of the analytes in mineral fertilizers by inductively coupled plasma optical emission spectrometry (ICP OES). - Highlights: • Determination of inorganic constituents in mineral fertilizers was proposed. • Experimental design methodology was used to optimize analytical method. • The sample preparation procedure using diluted reagents (HNO{sub 3} and H{sub 2}O{sub 2}) was employed. • The analytical method was satisfactorily to the determination of thirteen elements. • The

  20. ICP Mass and Optical Emission Spectrometry of Ore Samples Containing Rare Earth Elements

    International Nuclear Information System (INIS)

    Mohammed, A.E.W.M.

    2013-01-01

    Inductively Coupled Plasma Optical Emission and Mass Spectrometry (ICP-OES and ICPMS) are widely accepted as a rapid and sensitive techniques for Rare Earth Elements (REEs) analysis of geological samples. However, the achievable accuracy of these techniques are seriously limited by the problem of matrix interferences. In this study, matrix effects in ICP-AES were addressed using two approaches. In the first approach, the mechanisms of matrix interferences and analyte excitation were elucidated fundamentally. First, matrix effects from a comprehensive list of thirty-nine elements were investigated. It was confirmed that matrix elements with low second (instead of the widely reported first) ionization potentials (IP) produce a stronger matrix effect in all cases. Another critical parameter defining the severity of the matrix effect was found to be the availability of low-lying energy levels in the doubly charged matrix ion. Penning ionization followed by ion electron recombination through successive cycles is proposed as the mechanism for the more severe matrix effects caused by low second-IP matrices. In the second approach ICP-OES and ICP-MS are applied in this study for the analysis of Rare Earth Elements of two selected standard reference samples namely AGV-2 and BCR-2 beside a fluorspar geological sample (G-9 sample). Effective procedures are developed to avoid the spectral interference from matrix elements by using ion exchange resin Amberlite IR-120 before determination of REEs using ICP-OES and ICPMS. The potential of the method is evaluated by analysis of Certified Reference Materials (AGV-2 and BCR-2). Results obtained by ICP-MS show that experimental data are in agreement with the certified values and their values could be used as a quantitative data. The results obtained using ICP-OES were compared and discussed.

  1. The Determination of Composite Elements in Zircaloy-2 by X-Ray Fluorescence and Emission Spectrometry Method

    International Nuclear Information System (INIS)

    Dian Anggraini; Rosika Kriswarini; Yusuf N

    2007-01-01

    Analysis of composing elements in zircaloy-2 has been done by Emission Spectrometry method and X-Ray Fluorescence (XRF). The aim of the analysis is to verify conformity between composing elements in zircaloy-2 and the material certificate. Spectrometry Emission method has higher sensitivity in element determination of a material than that of XRF method, so can be estimated that emission spectrometry method has higher accuracy than that of XRF method. The result of qualitative analysis by Emission Spectrometry indicate that the composing elements in zircaloy-2 were Sn, Cr and Ni. However, the qualitative analysis result by XRF method indicated that the composing elements in zircaloy 2 were Sn, Cr, Ni and Fe. Fe element can not be analysed by Emission Spectrometry method because Emission Spectrometer did not equipped with Fe detector. The quantitative analysis result of the composing elements in the material with both methods showed that Sn, Cr and Ni concentration of zircaloy 2 existed in concentration ranges of the material certificate. Result of statistical test (F and t-test) of analysis result of both methods can be used for analyzing composing elements in zircaloy 2. Emission Spectrometry method was more sensitive and accurate for determining Cr and Ni element in zircaloy 2 than that of emission Spectrometry method but both methods had same accuracy. The precision of measurement of Sn, Cr and Ni element using XRF method was better than that of Emission spectrometry method. (author)

  2. Imaging of elements in leaves of tobacco by solid sampling–electrothermal vaporization–inductively coupled plasma-optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Masson, Pierre, E-mail: masson@bordeaux.inra.fr

    2014-12-01

    Plants take up and store elements according to the environment in which they are growing. Because plants are at the base of the food chain, the determination of essential elements or toxic elements in plant materials is of importance. However, it is assumed that the element content determined on selected tissues may provide more specific information than that derived from the whole plant analysis. In this work, we assessed the feasibility of solid sampling–electrothermal vaporization–inductively coupled plasma-optical emission spectrometry analyses for quantitative imaging of Cd and Mg in plant leaves. Leaves of tobacco (Nicotiana tabacum) were selected to be used as samples. To produce a two dimensional image, sections cut from leaf samples were analyzed. Cellulose doped with multi-element solution standards was used as calibration samples. Two certified reference materials (NIST SRM 1547 Peach Leaves and NIST SRM 1573a Tomato leaves) were used to verify the accuracy of measurements with good agreement between the measured concentrations and the certified values. Quantitative imaging revealed the inhomogeneous distribution of the selected elements. Excess of Cd and Mg tended to be focused on peripheral regions and the tip of the leaf.

  3. Determination of trace elements in soy milk using ICP atomic emission spectrometry

    International Nuclear Information System (INIS)

    Tanaka, Satoko; Chayama, Kenji

    2009-01-01

    The present study investigated the optimal method for the multi-element quantification of 9 elements in soy milk: calcium, copper, iron, potassium, magnesium, manganese, sodium, phosphorus, and zinc. Results obtained using ICP atomic emission spectrometry were compared with those obtained by atomic absorption spectrometry, which is the standard method. The same sample was measured using both ICP atomic emission spectrometry and atomic absorption spectrometry. The percentage of minerals recovered by ICP atomic emission spectrometry ranged from 99.3% to 102%, which was equivalent to that by atomic absorption spectrometry. Therefore, a good result with standard deviation was obtained. The mineral contents of 16 samples of commercially-available soy milk products were measured. The Cu content was significantly proportional to the amount of soybean solids (P < 0.001). Moreover, although relation-ships did not attain statistical significance, the consents of Fe, Zn, K, Mg and P were proportional to the amount of soybean solids, and were highest in soy milk, followed by prepared soy milk and so milk beverage. The Ca content of modified soy milk was significantly higher than that of soy milk and soy milk-based beverages (P < 0.001). Furthermore, the Na content in soy milk was significantly lower. (author)

  4. Nanometric resolution in glow discharge optical emission spectroscopy and Rutherford backscattering spectrometry depth profiling of metal (Cr, Al) nitride multilayers

    International Nuclear Information System (INIS)

    Escobar Galindo, R.; Gago, R.; Fornies, E.; Munoz-Martin, A.; Climent Font, A.; Albella, J.M.

    2006-01-01

    In this work, we address the capability of glow discharge optical emission spectroscopy (GDOES) for fast and accurate depth profiling of multilayer nitride coatings down to the nanometer range. This is shown by resolving the particular case of CrN/AlN structures with individual thickness ranging from hundreds to few nanometers. In order to discriminate and identify artefacts in the GDOES depth profile due to the sputtering process, the layered structures were verified by Rutherford backscattering spectrometry (RBS) and scanning electron microscopy (SEM). The interfaces in the GDOES profiles for CrN/AlN structures are sharper than the ones measured for similar metal multilayers due to the lower sputtering rate of the nitrides. However, as a consequence of the crater shape, there is a linear degradation of the depth resolution with depth (approximately 40 nm/μm), saturating at a value of approximately half the thickness of the thinner layer. This limit is imposed by the simultaneous sputtering of consecutive layers. The ultimate GDOES depth resolution at the near surface region was estimated to be of 4-6 nm

  5. Macro- and micro-element analysis in milk samples by inductively coupled plasma-optical emission spectrometry

    Directory of Open Access Journals (Sweden)

    Petrović Sanja M.

    2016-01-01

    Full Text Available The paper describes the determination of Ag, Al, B, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Ga, In, K, Li, Mg, Mn, Na, Ni, Pb, Sr, Tl and Zn, as well as total fat content of milk samples, originated from different sources. The analyzed milk samples were: human milk, fresh cow milk, pasteurized cow milk from a local market, and reconstituted powder milk. The milk samples were obtained from Jablanica District (Serbia territory. Preparation of samples for macro- and micro-analyses was done by wet digestion. Concentrations of the elements after digestion were determined by inductively coupled plasma optical emission spectrometry (ICP-OES. Total fat content of milk samples was determinate by the Weibull and Stoldt method. The results showed that potassium and calcium concentrations were the highest in all samples: 1840.64 - 2993.26 mg/L and 456.05 - 1318.08 mg/L, respectively. Of all heavy metals from the examined milk samples (copper, zinc, manganese, nickel, cadmium, and lead, the most common were zinc and copper, with approximately similar content in the range of 5 - 12 mg/l, while cadmium nickel and manganese were not detected at all. Samples of fresh cow milk and human milk showed the highest fat content of 3.6 and 4.2 %, respectively. Results for total fat and macro- and micro-analyses showed that fresh cow milk has the highest contents of fat and calcium, making it the most nutritious. [Projekat Ministarstva nauke Republike Srbije, br. TR 34012

  6. Fiber optics spectrochemical emission sensors

    Science.gov (United States)

    Griffin, Jeffrey W.; Olsen, Khris B.

    1992-01-01

    A method of in situ monitoring of a body of a fluid stored in a tank or groundwater or vadose zone gases in a well for the presence of selected chemical species uses a probe insertable into the well or tank via a cable and having electrical apparatus for exciting selected chemical species in the body of fluid. The probe can have a pair of electrodes for initiating a spark or a plasma cell for maintaining a plasma to excite the selected chemical species. The probe also has optical apparatus for receiving optical emissions emitted by the excited species and optically transmitting the emissions via the cable to an analysis location outside the well. The analysis includes detecting a selected wavelength in the emissions indicative of the presence of the selected chemical species. A plurality of probes can be suspended at an end of a respective cable, with the transmitting and analyzing steps for each probe being synchronized sequentially for one set of support equipment and instrumentation to monitor at multiple test points. The optical apparatus is arranged about the light guide axis so that the selected chemical species are excited the fluid in alignment with the light guide axis and optical emissions are received from the excited chemical species along such axis.

  7. Introduction of organic/hydro-organic matrices in inductively coupled plasma optical emission spectrometry and mass spectrometry: A tutorial review. Part II. Practical considerations

    Energy Technology Data Exchange (ETDEWEB)

    Leclercq, Amélie, E-mail: amelie.leclercq@cea.fr [CEA Saclay, DEN, DANS, DPC, SEARS, Laboratoire de développement Analytique Nucléaire Isotopique et Elémentaire, 91191 Gif-sur-Yvette (France); Nonell, Anthony, E-mail: anthony.nonell@cea.fr [CEA Saclay, DEN, DANS, DPC, SEARS, Laboratoire de développement Analytique Nucléaire Isotopique et Elémentaire, 91191 Gif-sur-Yvette (France); Todolí Torró, José Luis, E-mail: jose.todoli@ua.es [Universidad de Alicante, Departamento de Quimica Analitica, Nutricion y Bromatología, Ap. de Correos, 99, 03080 Alicante (Spain); Bresson, Carole, E-mail: carole.bresson@cea.fr [CEA Saclay, DEN, DANS, DPC, SEARS, Laboratoire de développement Analytique Nucléaire Isotopique et Elémentaire, 91191 Gif-sur-Yvette (France); Vio, Laurent, E-mail: laurent.vio@cea.fr [CEA Saclay, DEN, DANS, DPC, SEARS, Laboratoire de développement Analytique Nucléaire Isotopique et Elémentaire, 91191 Gif-sur-Yvette (France); Vercouter, Thomas, E-mail: thomas.vercouter@cea.fr [CEA Saclay, DEN, DANS, DPC, SEARS, Laboratoire de développement Analytique Nucléaire Isotopique et Elémentaire, 91191 Gif-sur-Yvette (France); Chartier, Frédéric, E-mail: frederic.chartier@cea.fr [CEA Saclay, DEN, DANS, DPC, 91191 Gif-sur-Yvette (France)

    2015-07-23

    Graphical abstract: This tutorial review is dedicated to the analysis of organic/hydro-organic matrices by ICP techniques. A state-of-the-art focusing on sample introduction, relevant operating parameters optimization and analytical strategies for elemental quantification is provided. - Highlights: • Practical considerations to perform analyses in organic/hydro-organic matrices. • Description, benefits and drawbacks of recent introduction devices. • Optimization to improve plasma tolerance towards organic/hydro-organic matrices. • Analytical strategies for elemental quantification in organic/hydro-organic matrices. - Abstract: Inductively coupled plasma optical emission spectrometry (ICP-OES) and mass spectrometry (ICP-MS) are increasingly used to carry out analyses in organic/hydro-organic matrices. The introduction of such matrices into ICP sources is particularly challenging and can be the cause of numerous drawbacks. This tutorial review, divided in two parts, explores the rich literature related to the introduction of organic/hydro-organic matrices in ICP sources. Part I provided theoretical considerations associated with the physico-chemical properties of such matrices, in an attempt to understand the induced phenomena. Part II of this tutorial review is dedicated to more practical considerations on instrumentation, instrumental and operating parameters, as well as analytical strategies for elemental quantification in such matrices. Two important issues are addressed in this part: the first concerns the instrumentation and optimization of instrumental and operating parameters, pointing out (i) the description, benefits and drawbacks of different kinds of nebulization and desolvation devices and the impact of more specific instrumental parameters such as the injector characteristics and the material used for the cone; and, (ii) the optimization of operating parameters, for both ICP-OES and ICP-MS. Even if it is at the margin of this tutorial review

  8. Introduction of organic/hydro-organic matrices in inductively coupled plasma optical emission spectrometry and mass spectrometry: A tutorial review. Part II. Practical considerations

    International Nuclear Information System (INIS)

    Leclercq, Amélie; Nonell, Anthony; Todolí Torró, José Luis; Bresson, Carole; Vio, Laurent; Vercouter, Thomas; Chartier, Frédéric

    2015-01-01

    Graphical abstract: This tutorial review is dedicated to the analysis of organic/hydro-organic matrices by ICP techniques. A state-of-the-art focusing on sample introduction, relevant operating parameters optimization and analytical strategies for elemental quantification is provided. - Highlights: • Practical considerations to perform analyses in organic/hydro-organic matrices. • Description, benefits and drawbacks of recent introduction devices. • Optimization to improve plasma tolerance towards organic/hydro-organic matrices. • Analytical strategies for elemental quantification in organic/hydro-organic matrices. - Abstract: Inductively coupled plasma optical emission spectrometry (ICP-OES) and mass spectrometry (ICP-MS) are increasingly used to carry out analyses in organic/hydro-organic matrices. The introduction of such matrices into ICP sources is particularly challenging and can be the cause of numerous drawbacks. This tutorial review, divided in two parts, explores the rich literature related to the introduction of organic/hydro-organic matrices in ICP sources. Part I provided theoretical considerations associated with the physico-chemical properties of such matrices, in an attempt to understand the induced phenomena. Part II of this tutorial review is dedicated to more practical considerations on instrumentation, instrumental and operating parameters, as well as analytical strategies for elemental quantification in such matrices. Two important issues are addressed in this part: the first concerns the instrumentation and optimization of instrumental and operating parameters, pointing out (i) the description, benefits and drawbacks of different kinds of nebulization and desolvation devices and the impact of more specific instrumental parameters such as the injector characteristics and the material used for the cone; and, (ii) the optimization of operating parameters, for both ICP-OES and ICP-MS. Even if it is at the margin of this tutorial review

  9. Preconcentration of heavy metals on activated carbon and their determination in fruits by inductively coupled plasma optical emission spectrometry.

    Science.gov (United States)

    Feist, Barbara; Mikula, Barbara

    2014-03-15

    A method of separation and preconcentration of cadmium, cobalt, copper, nickel, lead, and zinc at trace level using activated carbon is proposed. Activated carbon with the adsorbed trace metals was mineralised using a high-pressure microwave mineraliser. The heavy metals were determined after preconcentration by inductively coupled plasma optical emission spectrometry (ICP-OES). The influence of several parameters, such as pH, sorbent mass, shaking time was examined. Moreover, effects of inorganic matrix on recovery of the determined elements were studied. The experiment shows that foreign ions did not influence recovery of the determined elements. The detection limits (DL) of Cd, Co, Cu, Ni, Pb, and Zn were 0.17, 0.19, 1.60, 2.60, 0.92 and 1.50 μg L(-)(1), respectively. The recovery of the method for the determined elements was better than 95% with relative standard deviation from 1.3% to 3.7%. The preconcentration factor was 80. The proposed method was applied for determination of Cd, Co, Cu, Ni, Pb, and Zn in fruits materials. Accuracy of the proposed method was verified using certified reference material (NCS ZC85006 Tomato). Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Determination of Pb in river water samples by inductively coupled plasma optical emission spectrometry after ultrasound-assisted co-precipitation with manganese dioxide

    International Nuclear Information System (INIS)

    Sousa Bispo, Marcia; Santos da Boa Morte, Elane; Korn das Gracas Andrade, Maria; Sena Gomes Teixeira, Leonardo; Korn, Mauro; Costa, Antonio Celso Spinola

    2005-01-01

    A simple and efficient procedure for separation and pre-concentration using ultrasound-assisted co-precipitation with manganese dioxide was developed for Pb determination by inductively coupled plasma optical emission spectrometry (ICP OES). The optimization process was carried out using a two-level factorial design and a Doehlert matrix. Three variables (i.e. concentration of oxidizing solution-KMnO 4 , concentration of MnSO 4 solution and time of ultrasonic irradiation) were used as factors in the optimization. The recoveries, based on the analysis of spiked samples, were between 90% and 105%, and the precision was ≤ 5%. The detection limit and quantification limit for Pb determination were 3.2 and 10.7 μg L -1 , respectively. The proposed method was applied for the determination of Pb in water samples from a river heavily polluted by industrial effluents. The recovery measured by analyte addition technique showed that the proposed pre-concentration method had good accuracy

  11. Major constituent quantitative determination in uranium alloys by coupled plasma atomic emission spectrometry and X ray fluorescence wavelength dispersive spectrometry

    International Nuclear Information System (INIS)

    Oliveira, Luis Claudio de; Silva, Adriana Mascarenhas Martins da; Gomide, Ricardo Goncalves; Silva, Ieda de Souza

    2013-01-01

    A wavelength-dispersive X-ray fluorescence (WD-XRF) spectrometric method for determination of major constituents elements (Zr, Nb, Mo) in Uranium/Zirconium/Niobium and Uranium/Molybdenum alloy samples were developed. The methods use samples taken in the form of chips that were dissolved in hot nitric acid and precipitate particles melted with lithium tetraborate and dissolved in hot nitric acid and finally analyzed as a solution. Studies on the determination by inductively coupled plasma optic emission spectrometry (ICP OES) using matched matrix in calibration curve were developed. The same samples solution were analyzed in both methods. The limits of detection (LOD), linearity of the calibrations curves, recovery study, accuracy and precision of the both techniques were carried out. The results were compared. (author)

  12. Introduction of organic/hydro-organic matrices in inductively coupled plasma optical emission spectrometry and mass spectrometry: a tutorial review. Part I. Theoretical considerations.

    Science.gov (United States)

    Leclercq, Amélie; Nonell, Anthony; Todolí Torró, José Luis; Bresson, Carole; Vio, Laurent; Vercouter, Thomas; Chartier, Frédéric

    2015-07-23

    Due to their outstanding analytical performances, inductively coupled plasma optical emission spectrometry (ICP-OES) and mass spectrometry (ICP-MS) are widely used for multi-elemental measurements and also for isotopic characterization in the case of ICP-MS. While most studies are carried out in aqueous matrices, applications involving organic/hydro-organic matrices become increasingly widespread. This kind of matrices is introduced in ICP based instruments when classical "matrix removal" approaches such as acid digestion or extraction procedures cannot be implemented. Due to the physico-chemical properties of organic/hydro-organic matrices and their associated effects on instrumentation and analytical performances, their introduction into ICP sources is particularly challenging and has become a full topic. In this framework, numerous theoretical and phenomenological studies of these effects have been performed in the past, mainly by ICP-OES, while recent literature is more focused on applications and associated instrumental developments. This tutorial review, divided in two parts, explores the rich literature related to the introduction of organic/hydro-organic matrices in ICP-OES and ICP-MS. The present Part I, provides theoretical considerations in connection with the physico-chemical properties of organic/hydro-organic matrices, in order to better understand the induced phenomena. This focal point is divided in four chapters highlighting: (i) the impact of organic/hydro-organic matrices from aerosol generation to atomization/excitation/ionization processes; (ii) the production of carbon molecular constituents and their spatial distribution in the plasma with respect to analytes repartition; (iii) the subsequent modifications of plasma fundamental properties; and (iv) the resulting spectroscopic and non spectroscopic interferences. This first part of this tutorial review is addressed either to beginners or to more experienced scientists who are interested in the

  13. Trace element determination using static high-sensitivity inductively coupled plasma optical emission spectrometry (SHIP-OES).

    Science.gov (United States)

    Engelhard, Carsten; Scheffer, Andy; Nowak, Sascha; Vielhaber, Torsten; Buscher, Wolfgang

    2007-02-05

    A low-flow air-cooled inductively coupled plasma (ICP) design for optical emission spectrometry (OES) with axial plasma viewing is described and an evaluation of its analytical capabilities in trace element determinations is presented. Main advantage is a total argon consumption of 0.6 L min(-1) in contrast to 15 L min(-1) using conventional ICP sources. The torch was evaluated in trace element determinations and studied in direct comparison with a conventional torch under the same conditions with the same OES system, ultrasonic nebulization (USN) and single-element optimization. A variety of parameters (x-y-position of the torch, rf power, external air cooling, gas flow rates and USN operation parameters) was optimized to achieve limits of detection (LOD) which are competitive to those of a conventional plasma source. Ionic to atomic line intensity ratios for magnesium were studied at different radio frequency (rf) power conditions and different sample carrier gas flows to characterize the robustness of the excitation source. A linear dynamic range of three to five orders of magnitude was determined under compromise conditions in multi-element mode. The accuracy of the system was investigated by the determination of Co, Cr, Mn, Zn in two certified reference materials (CRM): CRM 075c (Copper with added impurities), and CRM 281 (Trace elements in rye grass). With standard addition values of 2.44+/-0.04 and 3.19+/-0.21 microg g(-1) for Co and Mn in the CRM 075c and 2.32+/-0.09, 81.8+/-0.4, 32.2+/-3.9 for Cr, Mn and Zn, respectively, were determined in the samples and found to be in good agreement with the reported values; recovery rates in the 98-108% range were obtained. No influence on the analysis by the matrix load in the sample was observed.

  14. On-line digestion in a focused microwave-assisted oven for elements determination in orange juice by inductively coupled plasma optical emission spectrometry

    Directory of Open Access Journals (Sweden)

    Fili Sabrina P.

    2003-01-01

    Full Text Available A flow injection system coupled to focused microwave-assisted oven was used for on-line orange juice sample digestion for determination of Ca, Cu, Fe, K, Mg, Mn, Na, P, and Zn by inductively coupled plasma optical emission spectrometry. The reactor coil was a PTFE tube (4.0 m long and 1.6 mm i.d. positioned into the commercial glass tube of the focused microwave oven. Aliquots of 500 muL of sample and 1000 muL of reagent (80% v/v HNO3 were mixed in a confluence and carried out to the reactor coil by air carrier. The relative standard deviation for five replicates of sample was lower than 5.0%. Good recoveries varying from 91 to 111% were obtained for added concentrations of the interest elements. The results obtained using the proposed digestion system are in agreement with those obtained for total digestion at the 95% confidence level. With this on-line digestion system was possible to carry out 12 samples h-1, minimizing contamination, saving consumption of samples and reagent and low residue generation.

  15. Anomalous optical emission in hot dense oxygen

    Science.gov (United States)

    Santoro, Mario; Gregoryanz, Eugene; Mao, Ho-kwang; Hemley, Russell J.

    2007-11-01

    We report the observation of unusually strong, broad-band optical emission peaked between 590 and 650 nm when solid and fluid oxygen are heated by a near infrared laser at pressures from 3 to 46 GPa. In situ Raman spectra of oxygen were collected and corresponding temperatures were measured from the Stokes/anti-Stokes intensity ratios of vibrational transitions. The intense optical emission overwhelmed the Raman spectrum at temperatures exceeding 750 K. The spectrum was found to be much narrower than Planck-type thermal emission, and the intensity increase with input power was much steeper than expected for the thermal emission. The result places an important general caveat on calculating temperatures based on optical emission spectra in high-pressure laser-heating experiments. The intense emission in oxygen is photo-induced rather than being purely thermal, through multiphoton or multi-step single photon absorption processes related to the interaction with infrared radiation. The results suggest that short lived ionic species are induced by this laser-matter interaction.

  16. Time-resolved laser-excited Shpol'skii spectrometry with a fiber-optic probe and ICCD camera

    International Nuclear Information System (INIS)

    Bystol, Adam J.; Campiglia, Andres D.; Gillispie, Gregory D.

    2000-01-01

    Improved methodology for chemical analysis via laser-excited Shpol'skii spectrometry is reported. The complications of traditional methodology for measurements at liquid nitrogen temperature are avoided by freezing the distal end of a bifurcated fiber-optic probe directly into the sample matrix. Emission wavelength-time matrices were rapidly collected by automatically incrementing the gate delay of an intensified charge-coupled device (ICCD) camera relative to the laser excitation pulse. The excitation source is a compact frequency-doubled tunable dye laser whose bandwidth (<0.03 nm) is well matched for Shpol'skii spectroscopy. Data reproducibility for quantitative analysis purposes and analytical figures of merit are demonstrated for several polycyclic aromatic hydrocarbons at 77 K. Although not attempted in this study, time-resolved excitation-emission matrices could easily be collected with this instrumental system. (c) 2000 Society for Applied Spectroscopy

  17. Analysis of cobalt, tantalum, titanium, vanadium and chromium in tungsten carbide by inductively coupled plasma-optical emission spectrometry

    CSIR Research Space (South Africa)

    Archer, M

    2003-12-01

    Full Text Available Inductively coupled plasma optical emission spectroscopy (ICP-OES) was used to measure the concentrations of cobalt, tantalum, titanium, vanadium and chromium in solutions of tungsten carbide. The main advantage of the method described here lies...

  18. Analysis of zirconium alloys using inductively-coupled plasma emission spectrometry

    International Nuclear Information System (INIS)

    White, G.F.; Pickford, C.J.

    1982-06-01

    As part of an interlaboratory collaborative exercise, certain trace and minor elements have been determined in a proposed zircaloy reference material using inductively-coupled plasma emission spectrometry. A dissolution procedure involving hydrochloric and hydrofluoric acids was used for determination of Hf, Cr, Fe and Sn. Data have also been obtained for Ni, Cu and Mn. Use of a high resolution monochromator in a scanning mode was found necessary for measurement of the emission intensities in order to resolve the spectral lines of interest from the intense and complex emission from the zirconium matrix. (author)

  19. Introduction of organic/hydro-organic matrices in inductively coupled plasma optical emission spectrometry and mass spectrometry: A tutorial review. Part I. Theoretical considerations

    Energy Technology Data Exchange (ETDEWEB)

    Leclercq, Amélie, E-mail: amelie.leclercq@cea.fr [CEA Saclay, DEN, DANS, DPC, SEARS, Laboratoire de développement Analytique Nucléaire Isotopique et Elémentaire, 91191 Gif-sur-Yvette (France); Nonell, Anthony, E-mail: anthony.nonell@cea.fr [CEA Saclay, DEN, DANS, DPC, SEARS, Laboratoire de développement Analytique Nucléaire Isotopique et Elémentaire, 91191 Gif-sur-Yvette (France); Todolí Torró, José Luis, E-mail: jose.todoli@ua.es [Universidad de Alicante, Departamento de Quimica Analitica, Nutricion y Bromatología, Ap. de Correos, 99, 03080 Alicante (Spain); Bresson, Carole, E-mail: carole.bresson@cea.fr [CEA Saclay, DEN, DANS, DPC, SEARS, Laboratoire de développement Analytique Nucléaire Isotopique et Elémentaire, 91191 Gif-sur-Yvette (France); Vio, Laurent, E-mail: laurent.vio@cea.fr [CEA Saclay, DEN, DANS, DPC, SEARS, Laboratoire de développement Analytique Nucléaire Isotopique et Elémentaire, 91191 Gif-sur-Yvette (France); Vercouter, Thomas, E-mail: thomas.vercouter@cea.fr [CEA Saclay, DEN, DANS, DPC, SEARS, Laboratoire de développement Analytique Nucléaire Isotopique et Elémentaire, 91191 Gif-sur-Yvette (France); Chartier, Frédéric, E-mail: frederic.chartier@cea.fr [CEA Saclay, DEN, DANS, DPC, 91191 Gif-sur-Yvette (France)

    2015-07-23

    Highlights: • Tutorial review addressed to beginners or more experienced analysts. • Theoretical background of effects caused by organic matrices on ICP techniques. • Spatial distribution of carbon species and analytes in plasma. • Carbon spectroscopic and non-spectroscopic interferences in ICP. - Abstract: Due to their outstanding analytical performances, inductively coupled plasma optical emission spectrometry (ICP-OES) and mass spectrometry (ICP-MS) are widely used for multi-elemental measurements and also for isotopic characterization in the case of ICP-MS. While most studies are carried out in aqueous matrices, applications involving organic/hydro-organic matrices become increasingly widespread. This kind of matrices is introduced in ICP based instruments when classical “matrix removal” approaches such as acid digestion or extraction procedures cannot be implemented. Due to the physico-chemical properties of organic/hydro-organic matrices and their associated effects on instrumentation and analytical performances, their introduction into ICP sources is particularly challenging and has become a full topic. In this framework, numerous theoretical and phenomenological studies of these effects have been performed in the past, mainly by ICP-OES, while recent literature is more focused on applications and associated instrumental developments. This tutorial review, divided in two parts, explores the rich literature related to the introduction of organic/hydro-organic matrices in ICP-OES and ICP-MS. The present Part I, provides theoretical considerations in connection with the physico-chemical properties of organic/hydro-organic matrices, in order to better understand the induced phenomena. This focal point is divided in four chapters highlighting: (i) the impact of organic/hydro-organic matrices from aerosol generation to atomization/excitation/ionization processes; (ii) the production of carbon molecular constituents and their spatial distribution in the

  20. Introduction of organic/hydro-organic matrices in inductively coupled plasma optical emission spectrometry and mass spectrometry: A tutorial review. Part I. Theoretical considerations

    International Nuclear Information System (INIS)

    Leclercq, Amélie; Nonell, Anthony; Todolí Torró, José Luis; Bresson, Carole; Vio, Laurent; Vercouter, Thomas; Chartier, Frédéric

    2015-01-01

    Highlights: • Tutorial review addressed to beginners or more experienced analysts. • Theoretical background of effects caused by organic matrices on ICP techniques. • Spatial distribution of carbon species and analytes in plasma. • Carbon spectroscopic and non-spectroscopic interferences in ICP. - Abstract: Due to their outstanding analytical performances, inductively coupled plasma optical emission spectrometry (ICP-OES) and mass spectrometry (ICP-MS) are widely used for multi-elemental measurements and also for isotopic characterization in the case of ICP-MS. While most studies are carried out in aqueous matrices, applications involving organic/hydro-organic matrices become increasingly widespread. This kind of matrices is introduced in ICP based instruments when classical “matrix removal” approaches such as acid digestion or extraction procedures cannot be implemented. Due to the physico-chemical properties of organic/hydro-organic matrices and their associated effects on instrumentation and analytical performances, their introduction into ICP sources is particularly challenging and has become a full topic. In this framework, numerous theoretical and phenomenological studies of these effects have been performed in the past, mainly by ICP-OES, while recent literature is more focused on applications and associated instrumental developments. This tutorial review, divided in two parts, explores the rich literature related to the introduction of organic/hydro-organic matrices in ICP-OES and ICP-MS. The present Part I, provides theoretical considerations in connection with the physico-chemical properties of organic/hydro-organic matrices, in order to better understand the induced phenomena. This focal point is divided in four chapters highlighting: (i) the impact of organic/hydro-organic matrices from aerosol generation to atomization/excitation/ionization processes; (ii) the production of carbon molecular constituents and their spatial distribution in the

  1. Mass and emission spectrometry in the Analytical Chemistry Division of Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D.H. (ed.)

    1978-11-01

    The capabilities of the Mass and Emission Spectrometry Section of the Analytical Chemistry Division of Oak Ridge National Laboratory are described. Many different areas of mass spectrometric expertise are represented in the section: gas analysis, high abundance sensitivity measurements, high- and low-resolution organic analyses, spark source trace constituent analysis, and ion microprobe analysis of surfaces. These capabilities are complemented by emission spectrometry. The instruments are described along with a few applications, some of which are unique.

  2. Mass and emission spectrometry in the Analytical Chemistry Division of Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Smith, D.H.

    1978-11-01

    The capabilities of the Mass and Emission Spectrometry Section of the Analytical Chemistry Division of Oak Ridge National Laboratory are described. Many different areas of mass spectrometric expertise are represented in the section: gas analysis, high abundance sensitivity measurements, high- and low-resolution organic analyses, spark source trace constituent analysis, and ion microprobe analysis of surfaces. These capabilities are complemented by emission spectrometry. The instruments are described along with a few applications, some of which are unique

  3. Simultaneous determination of macro and trace elements in biological reference materials by microwave induced plasma optical emission spectrometry with slurry sample introduction

    International Nuclear Information System (INIS)

    Matusiewicz, Henryk; Golik, Bartosz

    2004-01-01

    A slurry sampling technique (SST) has been utilized for simultaneous multi-element analysis by microwave-induced plasma optical emission spectrometry (MIP-OES). Slurry samples from a spray chamber are fed directly into the microwave cavity-torch assembly (power 300 W) with no desolvation apparatus. The performance of SST-MIP-OES was demonstrated by the determination of macro (Na, K, Ca, Mg, P) and trace (Cd, Cu, Mn, Sr, Zn) elements in three biological certified reference materials using a V-groove, clog-free Babington-type nebulizer. Slurry concentrations up to 1% m/v (particles 3 (pH 1.2) containing 0.01% of Triton X-100, were used with calibration by the standard additions method. The method offers relatively good precision (R.S.D. ranged from 7 to 11%) with measured concentrations being in satisfactory agreement with certified values for NRCC TORT-1 (Lobster hepatopancreas), NRCC LUTS-1 (Lobster hepatopancreas) and IAEA-153 (Milk powder). The concentrations of Na, K, Ca, Mg, P and Cd, Cu, Mn, Sr, Zn were determined in the range 90-22 000 μg/g and 1-420 μg/g, respectively. The method could be useful as a routine procedure

  4. Direct multielement trace analyses of silicon carbide powders by spark ablation simultaneous inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Kiera, Arne F.; Schmidt-Lehr, Sebastian; Song, Ming; Bings, Nicolas H.; Broekaert, Jose A.C.

    2008-01-01

    A procedure for the direct analysis of silicon carbide powders (SiC) by simultaneous detection inductively coupled plasma optical emission spectrometry using a Spectro-CIROS TM spectrometer (CCD-ICP-OES) and a novel spark ablation system Spectro-SASSy (SA) as sample introduction technique is described. The sample preparation procedure for SA of non-conducting material is based on mixing the sample powders with a conducting matrix, in this case copper and briquetting pellets. Pressing time, pressure and mixing ratio are shown to be important parameters of the pelleting technique with respect to their mechanical stability for the reliability of the analysis results. A mixing ratio of 0.2 g +0.6 g for SiC and Cu, a pressure of 10 t cm -2 and a pressing time of 8 min have been found optimum. It has also been shown that the spark parameters selected are crucial for uniform volatilization. Electron probe micrographs of the burning spots and the analytical signal magnitude showed that a rather hard spark at 100 Hz was optimum. The determination of trace elements in silicon carbide powders is demonstrated using a calibration based on the addition of standard solutions. For Al, Ti, V, Mn and Fe detection limits in the lower μg g -1 range can be achieved. Internal standardization with Y in combination with the addition of standard solutions allows relative standard deviations in the range of 4 to 24% for concentration levels of the order of 3 to 350 μg g -1

  5. Direct multielement trace analyses of silicon carbide powders by spark ablation simultaneous inductively coupled plasma optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kiera, Arne F.; Schmidt-Lehr, Sebastian; Song, Ming [Institute for Inorganic and Applied Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany); Bings, Nicolas H. [Institute for Inorganic and Applied Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany)], E-mail: bings@chemie.uni-hamburg.de; Broekaert, Jose A.C. [Institute for Inorganic and Applied Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany)

    2008-02-15

    A procedure for the direct analysis of silicon carbide powders (SiC) by simultaneous detection inductively coupled plasma optical emission spectrometry using a Spectro-CIROS{sup TM} spectrometer (CCD-ICP-OES) and a novel spark ablation system Spectro-SASSy (SA) as sample introduction technique is described. The sample preparation procedure for SA of non-conducting material is based on mixing the sample powders with a conducting matrix, in this case copper and briquetting pellets. Pressing time, pressure and mixing ratio are shown to be important parameters of the pelleting technique with respect to their mechanical stability for the reliability of the analysis results. A mixing ratio of 0.2 g +0.6 g for SiC and Cu, a pressure of 10 t cm{sup -2} and a pressing time of 8 min have been found optimum. It has also been shown that the spark parameters selected are crucial for uniform volatilization. Electron probe micrographs of the burning spots and the analytical signal magnitude showed that a rather hard spark at 100 Hz was optimum. The determination of trace elements in silicon carbide powders is demonstrated using a calibration based on the addition of standard solutions. For Al, Ti, V, Mn and Fe detection limits in the lower {mu}g g{sup -1} range can be achieved. Internal standardization with Y in combination with the addition of standard solutions allows relative standard deviations in the range of 4 to 24% for concentration levels of the order of 3 to 350 {mu}g g{sup -1}.

  6. Glow discharge optical emission spectroscopy for accurate and well resolved analysis of coatings and thin films

    KAUST Repository

    Wilke, Marcus

    2011-12-01

    In the last years, glow discharge optical emission spectrometry (GDOES) gained more and more acceptance in the analysis of functional coatings. GDOES thereby represents an interesting alternative to common depth profiling techniques like AES and SIMS, based on its unique combination of high erosion rates and erosion depths, sensitivity, analysis of nonconductive layers and easy quantification even for light elements such as C, N, O and H. Starting with the fundamentals of GDOES, a short overview on new developments in instrument design for accurate and well resolved thin film analyses is presented. The article focuses on the analytical capabilities of glow discharge optical emission spectrometry in the analysis of metallic coatings and thin films. Results illustrating the high depth resolution, confirmation of stoichiometry, the detection of light elements in coatings as well as contamination on the surface or interfaces will be demonstrated by measurements of: a multilayer system Cr/Ti on silicon, interface contamination on silicon during deposition of aluminum, Al2O3-nanoparticle containing conversion coatings on zinc for corrosion resistance, Ti3SiC2 MAX-phase coatings by pulsed laser deposition and hydrogen detection in a V/Fe multilayer system. The selected examples illustrate that GDOES can be successfully adopted as an analytical tool in the development of new materials and coatings. A discussion of the results as well as of the limitations of GDOES is presented. © 2011 Elsevier B.V.

  7. An evaluation of inductively coupled plasma optical emission spectrometry using electrothermal atomisation sample introduction and photographic plate detection

    International Nuclear Information System (INIS)

    Khathing, D.T.; Pickford, C.J.

    1984-05-01

    A photographic radiation measurement approach has been used with an inductively coupled plasma source to evaluate and tabulate the more prominent optical emission lines of 66 elements. Compared with the more common sample introduction technique using nebulisation, increased sensitivity for multielement analysis of small samples was achieved by using a simple graphite electrothermal atomisation system. This was constructed to serve as a dual purpose atomiser ie both for Atomic Absorption and for Inductively Coupled Plasma Emission spectroscopy. The system offers the advantage of a wide multi-elemental coverage, but sensitivities achieved with photographic detection are poorer than those obtained photoelectrically. (author)

  8. GRB 090727 AND GAMMA-RAY BURSTS WITH EARLY-TIME OPTICAL EMISSION

    International Nuclear Information System (INIS)

    Kopač, D.; Gomboc, A.; Japelj, J.; Kobayashi, S.; Mundell, C. G.; Bersier, D.; Cano, Z.; Smith, R. J.; Steele, I. A.; Virgili, F. J.; Guidorzi, C.; Melandri, A.

    2013-01-01

    We present a multi-wavelength analysis of Swift gamma-ray burst GRB 090727, for which optical emission was detected during the prompt gamma-ray emission by the 2 m autonomous robotic Liverpool Telescope and subsequently monitored for a further two days with the Liverpool and Faulkes Telescopes. Within the context of the standard fireball model, we rule out a reverse shock origin for the early-time optical emission in GRB 090727 and instead conclude that the early-time optical flash likely corresponds to emission from an internal dissipation process. Putting GRB 090727 into a broader observational and theoretical context, we build a sample of 36 gamma-ray bursts (GRBs) with contemporaneous early-time optical and gamma-ray detections. From these GRBs, we extract a sub-sample of 18 GRBs, which show optical peaks during prompt gamma-ray emission, and perform detailed temporal and spectral analysis in gamma-ray, X-ray, and optical bands. We find that in most cases early-time optical emission shows sharp and steep behavior, and notice a rich diversity of spectral properties. Using a simple internal shock dissipation model, we show that the emission during prompt GRB phase can occur at very different frequencies via synchrotron radiation. Based on the results obtained from observations and simulation, we conclude that the standard external shock interpretation for early-time optical emission is disfavored in most cases due to sharp peaks (Δt/t < 1) and steep rise/decay indices, and that internal dissipation can explain the properties of GRBs with optical peaks during gamma-ray emission

  9. OBSERVATION OF CORRELATED OPTICAL AND GAMMA EMISSIONS FROM GRB 081126

    International Nuclear Information System (INIS)

    Klotz, A.; Boer, M.; Gendre, B.; Atteia, J. L.; Coward, D. M.; Imerito, A. C.

    2009-01-01

    We present an analysis of time-resolved optical emissions observed from the gamma-ray burst GRB 081126 during the prompt phase. The analysis employed time-resolved photometry using optical data obtained by the TAROT telescope, using BAT data from the Swift spacecraft, and time-resolved spectroscopy at high energies from the GBM instrument onboard the Fermi spacecraft. The optical emission of GRB 081126 is found to be compatible with the second gamma emission pulse shifted by a positive time lag of 8.4 ± 3.9 s. This is the first well-resolved observation of a time lag between optical and gamma emissions during a gamma-ray burst. Our observations could potentially provide new constraints on the fireball model for gamma-ray burst early emissions. Furthermore, observations of time lags between optical and gamma ray photons provides an exciting opportunity to constrain quantum gravity theories.

  10. A Correlated Optical and Gamma Emission from GRB 081126A

    International Nuclear Information System (INIS)

    Gendre, B.; Klotz, A.; Atteia, J. L.; Boeer, M.; Coward, D. M.; Imerito, A. C.

    2010-01-01

    We present an analysis of time-resolved optical emissions observed from the gamma-ray burst GRB 081126 during the prompt phase. The analysis employed time-resolved photometry using optical data obtained by the TAROT telescope, BAT data from the Swift spacecraft and time-resolved spectroscopy at high energies from the GBM instrument onboard the Fermi spacecraft. The optical emission of GRB 081126 is found to be compatible with the second gamma emission pulse shifted by a positive time-lag of 8.4±3.9 sec. This is the first well resolved observation of a time lag between optical and gamma emissions during a gamma-ray burst. Our observations could potentially provide new constraints on the fireball model for gamma ray burst early emissions. Furthermore, observations of time-lags between optical and gamma ray photons provides an exciting opportunity to constrain quantum gravity theories.

  11. Dispersive liquid-liquid microextraction for simultaneous determination of cadmium, cobalt, lead and nickel in water samples by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Dos Santos Silva, E.; Correia, L.O.; Dos Santos, L.O.; Dos Santos Vieira, E.V.; Lemos, V.A.

    2012-01-01

    We report on a new method for the dispersive liquid-liquid microextraction of Cd(II), Co(II), Pb(II) and Ni (II) from water samples prior to their simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The procedure is based on the injection of a ternary solvent system composed of appropriate quantities of extraction solvent (trichloroethylene), dispersive solvent (ethanol), and the chelating reagent 2-(2'-benzothiazolylazo)-p-cresol into the sample solution. The solution turns turbid immediately after injection, and the analytes are extracted into the droplets of the organic phase which was dried and dissolved in a mixture of Triton X-114, nitric acid, and ethanol. The metal ions in this mixture were quantified by ICP-OES. The detection limits under optimized conditions are 0.2, 0.3, 0.2 and 0.7 μg L -1 for Cd(II), Co(II), Pb(II) and Ni(II), respectively. The enrichment factors were also calculated for Cd (13), Co (11), Pb (11) and Ni (8). The procedure was applied to the determination of cadmium, cobalt, lead and nickel in certified reference material (waterway sediment) and water samples. (author)

  12. Simultaneous determination of macro and trace elements in biological reference materials by microwave induced plasma optical emission spectrometry with slurry sample introduction

    Energy Technology Data Exchange (ETDEWEB)

    Matusiewicz, Henryk E-mail: Henryk.Matusiewicz@put.poznan.pl; Golik, Bartosz

    2004-05-21

    A slurry sampling technique (SST) has been utilized for simultaneous multi-element analysis by microwave-induced plasma optical emission spectrometry (MIP-OES). Slurry samples from a spray chamber are fed directly into the microwave cavity-torch assembly (power 300 W) with no desolvation apparatus. The performance of SST-MIP-OES was demonstrated by the determination of macro (Na, K, Ca, Mg, P) and trace (Cd, Cu, Mn, Sr, Zn) elements in three biological certified reference materials using a V-groove, clog-free Babington-type nebulizer. Slurry concentrations up to 1% m/v (particles <20 {mu}m), prepared in 10% HNO{sub 3} (pH 1.2) containing 0.01% of Triton X-100, were used with calibration by the standard additions method. The method offers relatively good precision (R.S.D. ranged from 7 to 11%) with measured concentrations being in satisfactory agreement with certified values for NRCC TORT-1 (Lobster hepatopancreas), NRCC LUTS-1 (Lobster hepatopancreas) and IAEA-153 (Milk powder). The concentrations of Na, K, Ca, Mg, P and Cd, Cu, Mn, Sr, Zn were determined in the range 90-22 000 {mu}g/g and 1-420 {mu}g/g, respectively. The method could be useful as a routine procedure.

  13. Improvement of the detection limits in radio-frequency-powered glow discharge optical emission spectrometry associated with bias-current conduction method; Jiko bias denryu donyuho ni yoru koshuha glow hoden hakko bunseki ni okeru kenshutsu genkai no kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Wagatsuma, K. [Tohoku University, Sendai (Japan). Research Institute for Materials

    1999-01-01

    A d.c. bias current driven by the self-bias voltage which is conducted through the r.f.-powered glow discharge plasma varies the emission characteristics drastically, leading to improvement of the detection power in the optical emission spectrometry. By conducting the bias currents of 20-30 mA, the emission intensities of the atomic resonance lines were 10-20 times larger than those obtained with conventional r.t.- powered plasmas. The detection limits for determination of alloyed elements in the re-based binary alloy samples were estimated to be l.6 x 10{sup -3}% Cr for CrI 425.43nm, 7 x 10{sup -4}% Mn for MnI 403.10nm, 1.9>10{sup -3}% Cu for CuI 327.40nm, 1.1 x 10{sup -3}% Al for AlI 396.16nm, and 6.6 x 10{sup -3}% Ni for NiI 352.45 nm. (author)

  14. Matrix digestion of soil and sediment samples for extraction of lead, cadmium and antimony and their direct determination by inductively coupled plasma-mass spectrometry and atomic emission spectrometry

    International Nuclear Information System (INIS)

    Chattopadhyay, P.; Fisher, A.S.; Henon, D.N.; Hill, S.J.

    2004-01-01

    An environmentally friendly and simple method has been developed for complete digestion of lead, cadmium and antimony from soil samples using a magnesium nitrate assisted dry ashing procedure. Statistical data for a series of experiments with standard reference materials are presented, and precision values are found to be comparable for inductively coupled plasma-mass spectrometry and for inductively coupled plasma-atomic emission spectrometry. From a single digest solution all analytes are quantified without involving any preconcentration routes. Inter-method comparison of inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES) shows that the probability of the results being different is less than 99 %. (author)

  15. Optical emission from Al target irradiated by FLASH

    International Nuclear Information System (INIS)

    Stránský, M; Rohlena, K

    2014-01-01

    The following text touches on some peculiarities in optical emission spectroscopy results from experiments on the free-electron laser FLASH [1, 2]. Aluminum targets were irradiated with 13.5 nm ∼ 25 fs pulses at intensities of 10 13 and 10 16 W/cm 2 (20 and 1 μm foci). Surprisingly, only neutral atom lines for the case with wider focus and traces of ion lines in the tighter focus case were observed with the optical emission spectroscopy (200–600 nm range), [2]. The motivating idea behind this work is the suggestion in [1] by Zastrau that the optical spectrometer sees only emissions from a cold expanding lower-density (< 10 22 cm −3 ) plasma plume. In this contribution the notion of UV range screening is analyzed in detail.

  16. Analysis of iron-base alloys by low-wattage glow discharge emission spectrometry

    International Nuclear Information System (INIS)

    Wagatsuma, K.; Hirokawa, K.

    1984-01-01

    Several iron-base alloys were investigated by low-wattage glow discharge emission spectrometry. The emission intensity principally depended on the sputtering parameters of constituent elements in the alloy. However, in the case of chromium, stable and firm oxides formed on the surface influencing the yield of ejected atoms. This paper discusses the relation between the sputtering parameters in Fe-Ni, Fe-Cr, and Fe-Co alloys and their relative emission intensities. Additionally, quantitative analysis was performed for some ternary iron-base alloys and commercial stainless steels with the calibration factors of binary alloy systems

  17. A rapid and practical strategy for the determination of platinum, palladium, ruthenium, rhodium, iridium and gold in large amounts of ultrabasic rock by inductively coupled plasma optical emission spectrometry combined with ultrasound extraction

    Science.gov (United States)

    Zhang, Gai; Tian, Min

    2015-04-01

    This proposed method regulated the determination of platinum, palladium, ruthenium, rhodium, iridium and gold in platinum-group ores by nickel sulfide fire assay—inductively coupled plasma optical emission spectrometry (ICP-OES) combined with ultrasound extraction for the first time. The quantitative limits were 0.013-0.023μg/g. The samples were fused to separate the platinum-group elements from matrix. The nickel sulfide button was then dissolved with hydrochloric acid and the insoluble platinum-group sulfide residue was dissolved with aqua regia by ultrasound bath and finally determined by ICP-OES. The proposed method has been applied into the determination of platinum-group element and gold in large amounts of ultrabasic rocks from the Great Dyke of Zimbabwe.

  18. Smooth Optical Self-similar Emission of Gamma-Ray Bursts

    Energy Technology Data Exchange (ETDEWEB)

    Lipunov, Vladimir; Simakov, Sergey; Gorbovskoy, Evgeny; Vlasenko, Daniil, E-mail: lipunov2007@gmail.com [Lomonosov Moscow State University, Sternberg Astronomical Institute, Universitetsky prospect, 13, 119992, Moscow (Russian Federation)

    2017-08-10

    We offer a new type of calibration for gamma-ray bursts (GRB), in which some class of GRB can be marked and share a common behavior. We name this behavior Smooth Optical Self-similar Emission (SOS-similar Emission) and identify this subclasses of GRBs with optical light curves described by a universal scaling function.

  19. Transformation quantum optics: designing spontaneous emission using coordinate transformations

    DEFF Research Database (Denmark)

    Zhang, Jingjing; Wubs, Martijn; Ginzburg, Pavel

    2016-01-01

    Spontaneous decay is a fundamental quantum property of emitters that can be controlled in a material environment via modification of the local density of optical states (LDOS). Here we use transformation optics methods in order to design required density of states and thus spontaneous emission (S......, affect the LDOS in complex materials. Tailoring SE properties using transformation optics approach provides an innovative way for designing emission properties in a complex material environment needed for the development of active nanophotonic devices....

  20. Gas chromatography/plasma spectrometry - an important analytical tool for elemental speciation studies

    International Nuclear Information System (INIS)

    Wuilloud, Jorgelina C.A.; Wuilloud, Rodolfo G.; Vonderheide, Anne P.; Caruso, Joseph A.

    2004-01-01

    In this review, a full discussion and update of the state-of-the-art of gas chromatography (GC) coupled to all known plasma spectrometers is presented. A brief introductive discussion of the advantages and disadvantages of GC-plasma interfaces, as well as types of plasmas and mass spectrometers, is given. The plasma-based techniques covered include inductively coupled plasma mass spectrometry (ICP-MS) microwave-induced plasma optical emission spectrometry (MIP-OES), and inductively coupled plasma optical emission spectrometry (ICP-OES). Also, different variants of plasma sources, such as low power plasmas and glow discharge (GD) sources, are described and compared with respect to their capabilities in elemental speciation. Recent advances and alternative mass analyzers (collision/reaction cell; time-of-flight; double-focusing sector field) are also mentioned. Different aspects of the GC-plasma coupling are discussed with particular attention to the applications of these hyphenated techniques to the analysis of elemental species. Additionally, classical and modern sample preparation methods, including extraction and/or preconcentration and derivatization reactions, are presented and evaluated

  1. Optical emission from laser-produced chromium and magnesium ...

    Indian Academy of Sciences (India)

    Abstract. Parametric study of optical emission from two successive laser pulses pro- ... The hot laser-produced plasma radiates various types of emissions ..... lasers. The qualitative agreement of this analysis with our observations confirms.

  2. An ultrasound-assisted digestion method for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Ilander, Aki; Vaeisaenen, Ari

    2007-01-01

    A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a nebulizer gas flow of 0.6 L min -1 , auxiliary gas flow of 0.2 L min -1 and plasma power of 1400 W were used for radially viewed plasma. The analysis of SRM 1633b showed that the ultrasound-assisted method developed is highly comparable with the microwave digestion method standardized by the United States Environmental Protection Agency (EPA-3052). The ultrasound-assisted digestion with a digestion solution of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 81%. One exception is arsenic which resulted in recoveries of about 60% only; however, it could be digested with good recovery (>90%) using a digestion solution of 5 mL of water and 5 mL of aqua regia. The major advantage of the ultrasound-assisted digestion over microwave digestion is the high treatment rate (30 samples simultaneously with a sonication time of 18 min)

  3. Trends in preconcentration procedures for metal determination using atomic spectrometry techniques

    International Nuclear Information System (INIS)

    Godoi Pereira, M. de; Arruda, M.A.Z.

    2003-01-01

    Methods for metal preconcentration are often described in the literature. However, purposes are often different, depending on whether the methods are applied in environmental, clinical or technological fields. The respective method needs to be efficient, give high sensitivity, and ideally also is selective which is useful when used in combination with atomic spectroscopy. This review presents the actual tendencies in metal preconcentration using techniques such as flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS), hydride generation atomic absorption spectrometry (HGAAS), inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS). Procedures based on related to electrochemical, coprecipitation/precipitation, liquid-liquid and solid-liquid extraction and atom trapping mechanisms are presented. (author)

  4. The optical emission from the supernova remnant HB 3

    Science.gov (United States)

    Fesen, R. A.; Gull, T. R.

    1983-01-01

    The supernova remnant HB 3 was first detected as a radio source by Brown and Hazard (1953). On the basis of subsequent radio studies, it was concluded that the object was a supernova remnant (SNR). HB 3 is located at the far western edge of the H II region/molecular cloud complex W3-W4-W5 (IC 1795-1805-1848). However, a physical association of HB 3 with this complex is uncertain. In the present investigation, attention is called to the probability that HB 3 exhibits a more extensive optical emission structure than previously realized, and one which agrees well with both the position and morphology of the radio emission. It is found that narrow-passband optical images strongly suggest an almost complete optical emission shell for HB 3. Spectroscopic observations are, however, required to confirm that this emission is characteristic of a SNR.

  5. Determination of aluminium, scandium and rare earth elements by emission flame spectrometry

    International Nuclear Information System (INIS)

    Otruba, V.; Sommer, L.

    1989-01-01

    Emission spectrometry in nitrous oxide-acetylene flames in combination with a highly resolving double monochromator and sensitive detecting system enables simple, sensitive and selective determinations of aluminium, scandium and all rare earth elements with exception of cerium in complicated matrices. Calibration plots are linear for a large concentration interval (≤ 100 μgxml -1 ), detection limits are in ngxml -1 level and RSD does not exceed 3% on the optimal concentration level of the particular element. The determination of Al, Sc, Eu and Yb showed particular advantages as to methods using ICP-spectrometry. (orig.)

  6. Radio-frequency glow discharge spectrometry: A critical review

    International Nuclear Information System (INIS)

    Winchester, Michael R.; Payling, Richard

    2004-01-01

    This paper presents a critical review of analytical radio frequency glow discharge spectrometry (rf-GDS). The historical foundations of rf-GDS are described, and current knowledge of the fundamental physics of analytical rf glow discharges is discussed. Additionally, instrumentation, methodologies, and applications of rf glow discharge optical emission spectrometry (rf-GDOES) and mass spectrometry (rf-GDMS) are reviewed. Although other rf-GDS techniques have appeared [e.g. rf glow discharge atomic absorption spectrophotometry (rf-GDAAS)], the emphasis is placed upon rf-GDOES and rf-GDMS, because they have received by far the most interest from analytical chemical metrologists. This review also provides explanations of some developments that are needed for further progress in the field of analytical rf-GDS

  7. Extraction inductively coupled plasma-optical emission spectrometry (ICP-OES). Determination of traces of phosphorus in tungsten

    International Nuclear Information System (INIS)

    Bauer, G.; Wegscheider, W.; Mueller, K.

    1989-01-01

    A method for the separation and preconcentration of traces of phosphorus from tungsten was developed. Solid phase extraction of the phosphovanadomolybdate complex performed on a micro-column was applied. Phosphorus was determined by optical emission spectroscopy (OES) with inductively coupled plasma (ICP) excitation. A limit of detection of 0,4 μg/g P with respect to the solid phase is obtained. By directly coupling the extraction/elution step to the ICP instrument a detection limit of 0,06 μg/g P in W was achieved. Besides, the complexity of spectral evaluation in ICP-OES determinations of traces in spectralline-rich matrices is discussed. (Authors)

  8. Optical emission behavior and radiation resistance of epoxy resins

    International Nuclear Information System (INIS)

    Kawanishi, Shunichi; Udagawa, Akira; Hagiwara, Miyuki

    1987-11-01

    To make clear a mechanism of radiation resistance of epoxy resin systems, a role of energy trapping site induced in bisphenol A type epoxy resins cured with 4 kinds of aromatic amines (Φ N ) was studied in comparison with the case of aliphatic amine curing system through a measurement of optical emission. In the system of the epoxy resin cured with DETA, the optical emission from an excited state of bisphenol A unit of epoxy resin and a charge transfer complex was observed. On the other hand, the optical emission from Φ N was observed in the aromatic amine curing system. Their excitation spectrum consists of peaks of absorption spectrum of BA and those of Φ N , showing that the excited state of Φ N is formed through the excitation of both BA and Φ N . Therefore, the excited energy of BA transfers to the excited state of Φ N . Emission intensity of Φ N band was 20 ∼ 100 times as large as that of BA. These results indicate that the radiation energy is effectively released as an optical emission from excited state of Φ N in the epoxy resin when cured with aromatic amine. It can be concluded from the above results that aromatic amine hardeners contribute to enhancement of the radiation resistance of epoxy resin by acting as an energy transfer agent. (author)

  9. Optical spectroscopy versus mass spectrometry: The race for fieldable isotopic analysis

    International Nuclear Information System (INIS)

    Barshick, C.M.; Young, J.P.; Shaw, R.W.

    1995-01-01

    Several techniques have been developed to provide on-site isotopic analyses, including decay-counting and mass spectrometry, as well as methods that rely on the accessibility of optical transitions for isotopic selectivity (e.g., laser-induced fluorescence and optogalvanic spectroscopy). The authors have been investigating both mass spectrometry and optogalvanic spectroscopy for several years. Although others have considered these techniques for isotopic analysis, the authors have focussed on the use of a dc glow discharge for atomization and ionization, and a demountable discharge cell for rapid sample exchange. The authors' goal is a fieldable instrument that provides useful uranium isotope ratio information

  10. A link between prompt optical and prompt gamma-ray emission in gamma-ray bursts.

    Science.gov (United States)

    Vestrand, W T; Wozniak, P R; Wren, J A; Fenimore, E E; Sakamoto, T; White, R R; Casperson, D; Davis, H; Evans, S; Galassi, M; McGowan, K E; Schier, J A; Asa, J W; Barthelmy, S D; Cummings, J R; Gehrels, N; Hullinger, D; Krimm, H A; Markwardt, C B; McLean, K; Palmer, D; Parsons, A; Tueller, J

    2005-05-12

    The prompt optical emission that arrives with the gamma-rays from a cosmic gamma-ray burst (GRB) is a signature of the engine powering the burst, the properties of the ultra-relativistic ejecta of the explosion, and the ejecta's interactions with the surroundings. Until now, only GRB 990123 had been detected at optical wavelengths during the burst phase. Its prompt optical emission was variable and uncorrelated with the prompt gamma-ray emission, suggesting that the optical emission was generated by a reverse shock arising from the ejecta's collision with surrounding material. Here we report prompt optical emission from GRB 041219a. It is variable and correlated with the prompt gamma-rays, indicating a common origin for the optical light and the gamma-rays. Within the context of the standard fireball model of GRBs, we attribute this new optical component to internal shocks driven into the burst ejecta by variations of the inner engine. The correlated optical emission is a direct probe of the jet isolated from the medium. The timing of the uncorrelated optical emission is strongly dependent on the nature of the medium.

  11. Pulsed, atmospheric pressure plasma source for emission spectrometry

    Science.gov (United States)

    Duan, Yixiang; Jin, Zhe; Su, Yongxuan

    2004-05-11

    A low-power, plasma source-based, portable molecular light emission generator/detector employing an atmospheric pressure pulsed-plasma for molecular fragmentation and excitation is described. The average power required for the operation of the plasma is between 0.02 W and 5 W. The features of the optical emission spectra obtained with the pulsed plasma source are significantly different from those obtained with direct current (dc) discharge higher power; for example, strong CH emission at 431.2 nm which is only weakly observed with dc plasma sources was observed, and the intense CN emission observed at 383-388 nm using dc plasma sources was weak in most cases. Strong CN emission was only observed using the present apparatus when compounds containing nitrogen, such as aniline were employed as samples. The present apparatus detects dimethylsulfoxide at 200 ppb using helium as the plasma gas by observing the emission band of the CH radical. When coupled with a gas chromatograph for separating components present in a sample to be analyzed, the present invention provides an apparatus for detecting the arrival of a particular component in the sample at the end of the chromatographic column and the identity thereof.

  12. Amplified spontaneous emission and laser emission from a high optical-gain medium of dye-doped dendrimer

    International Nuclear Information System (INIS)

    Yokoyama, Shiyoshi; Nakahama, Tatsuo; Mashiko, Shinro

    2005-01-01

    We measured the amplified spontaneous emission and laser emission from high-gain media of laser-dye encapsulated dendrimers. A highly branched poly(amidoamine) (PAMAM-OH) dendrimer formed a guest-host complex with a conventional laser-dye (DCM), resulting in a high optical-gain. Of particular note was the appearance of a laser threshold, above which a super-narrowed laser spectrum was observed, although laser feedback was caused without any mirror cavity devices. The optical feedback was attributed to spatial confinement of the light due to gain guiding under optical excitation. The laser spectrum clearly indicated a resonant laser-mode with a spectrum linewidth of less than 0.1 nm. This order of spectrum narrowing is comparable to that seen in the laser emission from ordinary laser devices

  13. Spatially and temporally resolved detection of arsenic in a capillary dielectric barrier discharge by hydride generation high-resolved optical emission spectrometry

    Czech Academy of Sciences Publication Activity Database

    Burhenn, S.; Kratzer, Jan; Svoboda, Milan; Klute, F. D.; Michels, A.; Veža, D.; Franzke, J.

    2018-01-01

    Roč. 90, MAR (2018), s. 3424-3429 ISSN 0003-2700 R&D Projects: GA ČR GA17-04329S Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * optical emission spectroscopy * arsenic hydride Subject RIV: CB - Analytical Chemistry , Separation OBOR OECD: Analytical chemistry Impact factor: 6.320, year: 2016

  14. Spatially and temporally resolved detection of arsenic in a capillary dielectric barrier discharge by hydride generation high-resolved optical emission spectrometry

    Czech Academy of Sciences Publication Activity Database

    Burhenn, S.; Kratzer, Jan; Svoboda, Milan; Klute, F. D.; Michels, A.; Veža, D.; Franzke, J.

    2018-01-01

    Roč. 90, MAR (2018), s. 3424-3429 ISSN 0003-2700 R&D Projects: GA ČR GA17-04329S Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * optical emission spectroscopy * arsenic hydride Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 6.320, year: 2016

  15. Validation of an analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals in soil.

    Science.gov (United States)

    Frentiu, Tiberiu; Ponta, Michaela; Hategan, Raluca

    2013-03-01

    The aim of this paper was the validation of a new analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals (Ag, Cd, Co, Cr, Cu, Ni, Pb and Zn) in soil after microwave assisted digestion in aqua regia. Determinations were performed on the ContrAA 300 (Analytik Jena) air-acetylene flame spectrometer equipped with xenon short-arc lamp as a continuum radiation source for all elements, double monochromator consisting of a prism pre-monocromator and an echelle grating monochromator, and charge coupled device as detector. For validation a method-performance study was conducted involving the establishment of the analytical performance of the new method (limits of detection and quantification, precision and accuracy). Moreover, the Bland and Altman statistical method was used in analyzing the agreement between the proposed assay and inductively coupled plasma optical emission spectrometry as standardized method for the multielemental determination in soil. The limits of detection in soil sample (3σ criterion) in the high-resolution continuum source flame atomic absorption spectrometry method were (mg/kg): 0.18 (Ag), 0.14 (Cd), 0.36 (Co), 0.25 (Cr), 0.09 (Cu), 1.0 (Ni), 1.4 (Pb) and 0.18 (Zn), close to those in inductively coupled plasma optical emission spectrometry: 0.12 (Ag), 0.05 (Cd), 0.15 (Co), 1.4 (Cr), 0.15 (Cu), 2.5 (Ni), 2.5 (Pb) and 0.04 (Zn). Accuracy was checked by analyzing 4 certified reference materials and a good agreement for 95% confidence interval was found in both methods, with recoveries in the range of 94-106% in atomic absorption and 97-103% in optical emission. Repeatability found by analyzing real soil samples was in the range 1.6-5.2% in atomic absorption, similar with that of 1.9-6.1% in optical emission spectrometry. The Bland and Altman method showed no statistical significant difference between the two spectrometric

  16. Determination of boron content and isotopic composition in gypsum by inductively coupled plasma optical emission spectroscopy and positive thermal ionization mass spectrometry using phase transformation.

    Science.gov (United States)

    Ma, Yun-Qi; Peng, Zhang-Kuang; Yang, Jian; Xiao, Ying-Kai; Zhang, Yan-Ling

    2017-12-01

    As a stable isotope, boron plays an important role in hydrogeology, environmental geochemistry, ore deposit geochemistry and marine paleoclimatology. However, there is no report of boron isotopic composition in gypsum. This is mainly confined to complete dissolution of Gypsum by water or acid. In this study, gypsum was converted to calcium carbonate (CaCO 3 ) with ammonium bicarbonate(NH 4 HCO 3 ) by two steps at 50°C. In every step, the mass ratio of NH 4 HCO 3 /CaSO 4 ·2H 2 O was twice, and conversion rate reached more than 98%. Converted CaCO 3 was totally dissolved with hydrochloric acid (the dissolution rate was over 99%). In order to overcome the difficulties of the matrix interference and the detection limit of Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES), we use Amberlite IRA 743 resin to purify and enrichment the boron at first, then eluting boron from the resin with 10mL 0.1mol/L hydrochloric acid at 75°C. The boron isotopic composition of natural gypsum samples was determined using positive thermal ionization mass spectrometry (P-TIMS). The boron isotopic composition of gypsum may be an excellent indicator for the formation environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Remote spectrometry with optical fibers, ten years of development and prospects for on-line control

    International Nuclear Information System (INIS)

    Boisde, G.; Perez, J.J.

    1984-09-01

    This paper describes, with examples uranium and plutonium spectra, how optical fibers have raised new concepts in spectrometry, such as the internal spectral reference, instantaneous measurements on the sides of the absorption spectra, and the modelling of spectral variations. With optical fibers, original technical solutions are used for remote chemical analysis

  18. Sequential cloud point extraction for the speciation of mercury in seafood by inductively coupled plasma optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li Yingjie [Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu Bin [Department of Chemistry, Wuhan University, Wuhan 430072 (China)], E-mail: binhu@whu.edu.cn

    2007-10-15

    A novel nonchromatographic speciation technique for the speciation of mercury by sequential cloud point extraction (CPE) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed. The method based on Hg{sup 2+} was complexed with I{sup -} to form HgI{sub 4}{sup 2-}, and the HgI{sub 4}{sup 2-} reacted with the methyl green (MG) cation to form hydrophobic ion-associated complex, and the ion-associated complex was then extracted into the surfactant-rich phase of the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114), which are subsequently separated from methylmercury (MeHg{sup +}) in the initial solution by centrifugation. The surfactant-rich phase containing Hg(II) was diluted with 0.5 mol L{sup -1} HNO{sub 3} for ICP-OES determination. The supernatant is also subjected to the similar CPE procedure for the preconcentration of MeHg{sup +} by the addition of a chelating agent, ammonium pyrrolidine dithiocarbamate (APDC), in order to form water-insolvable complex with MeHg{sup +}. The MeHg{sup +} in the micelles was directly analyzed after disposal as describe above. Under the optimized conditions, the extraction efficiency was 93.5% for Hg(II) and 51.5% for MeHg{sup +} with the enrichment factor of 18.7 for Hg(II) and 10.3 for MeHg{sup +}, respectively. The limits of detection (LODs) were 56.3 ng L{sup -1} for Hg(II) and 94.6 ng L{sup -1} for MeHg{sup +} (as Hg) with the relative standard deviations (RSDs) of 3.6% for Hg(II) and 4.5% for MeHg{sup +} (C = 10 {mu}g L{sup -1}, n = 7), respectively. The developed technique was applied to the speciation of mercury in real seafood samples and the recoveries for spiked samples were found to be in the range of 93.2-108.7%. For validation, a certified reference material of DORM-2 (dogfish muscle) was analyzed and the determined values are in good agreement with the certified values.

  19. Sequential cloud point extraction for the speciation of mercury in seafood by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Li Yingjie; Hu Bin

    2007-01-01

    A novel nonchromatographic speciation technique for the speciation of mercury by sequential cloud point extraction (CPE) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed. The method based on Hg 2+ was complexed with I - to form HgI 4 2- , and the HgI 4 2- reacted with the methyl green (MG) cation to form hydrophobic ion-associated complex, and the ion-associated complex was then extracted into the surfactant-rich phase of the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114), which are subsequently separated from methylmercury (MeHg + ) in the initial solution by centrifugation. The surfactant-rich phase containing Hg(II) was diluted with 0.5 mol L -1 HNO 3 for ICP-OES determination. The supernatant is also subjected to the similar CPE procedure for the preconcentration of MeHg + by the addition of a chelating agent, ammonium pyrrolidine dithiocarbamate (APDC), in order to form water-insolvable complex with MeHg + . The MeHg + in the micelles was directly analyzed after disposal as describe above. Under the optimized conditions, the extraction efficiency was 93.5% for Hg(II) and 51.5% for MeHg + with the enrichment factor of 18.7 for Hg(II) and 10.3 for MeHg + , respectively. The limits of detection (LODs) were 56.3 ng L -1 for Hg(II) and 94.6 ng L -1 for MeHg + (as Hg) with the relative standard deviations (RSDs) of 3.6% for Hg(II) and 4.5% for MeHg + (C = 10 μg L -1 , n = 7), respectively. The developed technique was applied to the speciation of mercury in real seafood samples and the recoveries for spiked samples were found to be in the range of 93.2-108.7%. For validation, a certified reference material of DORM-2 (dogfish muscle) was analyzed and the determined values are in good agreement with the certified values

  20. Improved documentation of spectral lines for inductively coupled plasma emission spectrometry

    Science.gov (United States)

    Doidge, Peter S.

    2018-05-01

    An approach to improving the documentation of weak spectral lines falling near the prominent analytical lines used in inductively coupled plasma optical emission spectrometry (ICP-OES) is described. Measurements of ICP emission spectra in the regions around several hundred prominent lines, using concentrated solutions (up to 1% w/v) of some 70 elements, and comparison of the observed spectra with both recent published work and with the output of a computer program that allows calculation of transitions between the known energy levels, show that major improvements can be made in the coverage of spectral atlases for ICP-OES, with respect to "classical" line tables. It is argued that the atomic spectral data (wavelengths, energy levels) required for the reliable identification and documentation of a large majority of the weak interfering lines of the elements detectable by ICP-OES now exist, except for most of the observed lines of the lanthanide elements. In support of this argument, examples are provided from a detailed analysis of a spectral window centered on the prominent Pb II 220.353 nm line, and from a selected line-rich spectrum (W). Shortcomings in existing analyses are illustrated with reference to selected spectral interferences due to Zr. This approach has been used to expand the spectral-line library used in commercial ICP-ES instruments (Agilent 700-ES/5100-ES). The precision of wavelength measurements is evaluated in terms of the shot-noise limit, while the absolute accuracy of wavelength measurement is characterised through comparison with a small set of precise Ritz wavelengths for Sb I, and illustrated through the identification of Zr III lines; it is further shown that fractional-pixel absolute wavelength accuracies can be achieved. Finally, problems with the wavelengths and classifications of certain Au I lines are discussed.

  1. Thermoluminescence emission spectrometry of glass display in mobile phones and resulting evaluation of the dosimetric properties of a specific type of display glass

    International Nuclear Information System (INIS)

    Discher, Michael; Woda, Clemens

    2014-01-01

    Glass displays of mobile phones are sensitive to ionizing radiation and can be used for retrospective dosimetry for the purpose of triage after a radiological accident or attack. In this study the two main types of glass display that are used in modern mobile phones were investigated using thermoluminescence (TL) emission spectrometry. A different TL spectrum was observed for the glass display of category A (lime-aluminosilicate glass) and category B (boron-silicate glass). Based on the spectral measurements an optimized detection window was chosen to re-evaluate the dosimetric properties (dose response, optical and long-term stability) of glass display category B. - Highlights: • Two display glass types show similar TL emission peaks but with strongly different relative intensities. • The intrinsic background TL signal peaks at similar wavelengths as the radiation induced signal. • Dosimetric properties of one display glass type were re-evaluated using an optimized detection window

  2. A young source of optical emission from distant radio galaxies.

    Science.gov (United States)

    Hammer, F; Fèvre, O Le; Angonin, M C

    1993-03-25

    DISTANT radio galaxies provide valuable insights into the properties of the young Universe-they are the only known extended optical sources at high redshift and might represent an early stage in the formation and evolution of galaxies in general. This extended optical emission often has very complex morphologies, but the origin of the light is still unclear. Here we report spectroscopic observations for several distant radio galaxies (0.75≤ z ≤ 1.1) in which the rest-frame spectra exhibit featureless continua between 2,500 Å and 5,000 Å. We see no evidence for the break in the spectrum at 4,000 Å expected for an old stellar population 1-3 , and suggest that young stars or scattered emissions from the active nuclei are responsible for most of the observed light. In either case, this implies that the source of the optical emission is com-parable in age to the associated radio source, namely 10 7 years or less.

  3. Optical emissions from oxygen atom reactions with adsorbates

    Science.gov (United States)

    Oakes, David B.; Fraser, Mark E.; Gauthier-Beals, Mitzi; Holtzclaw, Karl W.; Malonson, Mark; Gelb, Alan H.

    1992-12-01

    Although most optical materials are inert to the ambient low earth orbit environment, high velocity oxygen atoms will react with adsorbates to produce optical emissions from the ultraviolet into the infrared. The adsorbates arise from chemical releases or outgassing from the spacecraft itself. We have been investigating kinetic and spectral aspects of these phenomenon by direct observation of the 0.2 to 13 micrometers chemiluminescence from the interaction of a fast atomic oxygen beam with a continuously dosed surface. The dosing gases include fuels, combustion products and outgassed species such as unsymmetrical dimethylhydrazine (UDMH), NO, H2O and CO. The surface studied include gold and magnesium fluoride. In order to relate the results to actual spacecraft conditions these phenomena have been explored as a function of O atom velocity, dosant flux and substrate temperature. UDMH dosed surfaces exhibit spectra typical (wavelength and intensity) of carbonaceous surfaces. The primary emitters are CO, CO2, and OH. H2O dosed surfaces are dominated by OH and /or H2O emission while CO dosed surfaces are dominated by CO and CO2 emissions. The nitric oxide dosed surface produces a glow from 0.4 to 5.4 micrometers due to NO2* continuum emission. The emission was observed to increase by a factor of two upon cooling the surface from 20 degree(s)C to -35 degree(s)C.

  4. Comparative study of injection into a pneumatic nebuliser and tungsten coil electrothermal vaporisation for the determination of rare earth elements by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Dittrich, K.

    1988-01-01

    Injection into a pneumatic nebuliser and vaporisation using a tungsten coil electrothermal vaporisation system, with a 3-kW argon-nitrogen inductively coupled plasma (ICP), are compared for the determination of the rare earth elements. The sampling efficiency and thus also the absolute power of detection of the tungsten coil ICP optical emission spectrometric (ICP-OES) technique are better by two orders of magnitude, than the injection technique. The absolute detection limits for the rare earth elements are at the pg level; for the refractory rare earth elements (Er, La, Lu and Y), they are lower than those obtained by graphite furnace atomic absorption spectrometry, whereas for the other rare earth elements (Eu, Sc, Tm and Yb), the detection limits are comparable. With injection of samples into a pneumatic nebuliser and ICP-OES, matrix effects are low and absolute amounts of the order of mg of the rare earth matrix can be tolerated, giving relative detection limits down to 1 μg g -1 . The amount of rare earth matrix that can be tolerated with the tungsten-coil atomiser is two orders of magnitude lower. Thus the relatively detection limits of the two methods are of the same order, although the matrix effects are considerably higher with the tungsten coil. (author)

  5. Optical radiation emissions from compact fluorescent lamps

    International Nuclear Information System (INIS)

    Khazova, M.; O'Hagan, J.B.

    2008-01-01

    There is a drive to energy efficiency to mitigate climate change. To meet this challenge, the UK Government has proposed phasing out incandescent lamps by the end of 2011 and replacing them with energy efficient fluorescent lighting, including compact fluorescent lamps (CFLs) with integrated ballasts. This paper presents a summary of an assessment conducted by the Health Protection Agency in March 2008 to evaluate the optical radiation emissions of CFLs currently available in the UK consumer market. The study concluded that the UV emissions from a significant percentage of the tested CFLs with single envelopes may result in foreseeable overexposure of the skin when these lamps are used in desk or task lighting applications. The optical output of all tested CFLs, in addition to high-frequency modulation, had a 100-Hz envelope with modulation in excess of 15%. This degree of modulation may be linked to a number of adverse effects. (authors)

  6. Phonon-assisted field emission in silicon nanomembranes for time-of-flight mass spectrometry of proteins.

    Science.gov (United States)

    Park, Jonghoo; Aksamija, Zlatan; Shin, Hyun-Cheol; Kim, Hyunseok; Blick, Robert H

    2013-06-12

    Time-of-flight (TOF) mass spectrometry has been considered as the method of choice for mass analysis of large intact biomolecules, which are ionized in low charge states by matrix-assisted-laser-desorption/ionization (MALDI). However, it remains predominantly restricted to the mass analysis of biomolecules with a mass below about 50,000 Da. This limitation mainly stems from the fact that the sensitivity of the standard detectors decreases with increasing ion mass. We describe here a new principle for ion detection in TOF mass spectrometry, which is based upon suspended silicon nanomembranes. Impinging ion packets on one side of the suspended silicon nanomembrane generate nonequilibrium phonons, which propagate quasi-diffusively and deliver thermal energy to electrons within the silicon nanomembrane. This enhances electron emission from the nanomembrane surface with an electric field applied to it. The nonequilibrium phonon-assisted field emission in the suspended nanomembrane connected to an effective cooling of the nanomembrane via field emission allows mass analysis of megadalton ions with high mass resolution at room temperature. The high resolution of the detector will give better insight into high mass proteins and their functions.

  7. Wireless Data Acquisition of Transient Signals for Mobile Spectrometry Applications.

    Science.gov (United States)

    Trzcinski, Peter; Weagant, Scott; Karanassios, Vassili

    2016-05-01

    Wireless data acquisition using smartphones or handhelds offers increased mobility, it provides reduced size and weight, it has low electrical power requirements, and (in some cases) it has an ability to access the internet. Thus, it is well suited for mobile spectrometry applications using miniaturized, field-portable spectrometers, or detectors for chemical analysis in the field (i.e., on-site). There are four main wireless communications standards that can be used for wireless data acquisition, namely ZigBee, Bluetooth, Wi-Fi, and UWB (ultra-wide band). These are briefly reviewed and are evaluated for applicability to data acquisition of transient signals (i.e., time-domain) in the field (i.e., on-site) from a miniaturized, field-portable photomultiplier tube detector and from a photodiode array detector installed in a miniaturized, field-portable fiber optic spectrometer. These are two of the most widely used detectors for optical measurements in the ultraviolet-visible range of the spectrum. A miniaturized, 3D-printed, battery-operated microplasma-on-a-chip was used for generation of transient optical emission signals. Elemental analysis from liquid microsamples, a microplasma, and a handheld or a smartphone will be used as examples. Development and potential applicability of wireless data acquisition of transient optical emission signals for taking part of the lab to the sample types of mobile, field-portable spectrometry applications will be discussed. The examples presented are drawn from past and ongoing work in the authors' laboratory. A handheld or a smartphone were used as the mobile computing devices of choice. © The Author(s) 2016.

  8. Optical crosstalk reduction using Amplified Spontaneous Emission (ASE)

    NARCIS (Netherlands)

    Chen, H.; Fontaine, N.K.; Ryf, R.; Alvarado, J.C.; van Weerdenburg, J.A.A.; Amezcua-Correa, R.; Okonkwo, C.; Koonen, A.M.J.

    2018-01-01

    We employ spectrally filtered amplified spontaneous emission as the signal carrier and matched local oscillator to mitigate optical crosstalk. We demonstrate polarization crosstalk reduction in single-mode fiber transmission and modal crosstalk reduction over multimode fiber.

  9. Non-exponential spontaneous emission dynamics for emitters in a time-dependent optical cavity

    NARCIS (Netherlands)

    Thyrrestrup Nielsen, Henri; Hartsuiker, A.; Gerard, J.M.; Vos, Willem L.

    2013-01-01

    We have theoretically studied the effect of deterministic temporal control of spontaneous emission in a dynamic optical microcavity. We propose a new paradigm in light emission: we envision an ensemble of two-level emitters in an environment where the local density of optical states is modified on a

  10. Optical emission from a small scale model electric arc furnace in 250-600 nm region.

    Science.gov (United States)

    Mäkinen, A; Niskanen, J; Tikkala, H; Aksela, H

    2013-04-01

    Optical emission spectroscopy has been for long proposed for monitoring and studying industrial steel making processes. Whereas the radiative decay of thermal excitations is always taking place in high temperatures needed in steel production, one of the most promising environment for such studies are electric arc furnaces, creating plasma in excited electronic states that relax with intense characteristic emission in the optical regime. Unfortunately, large industrial scale electric arc furnaces also present a challenging environment for optical emission studies and application of the method is not straightforward. To study the usability of optical emission spectroscopy in real electric arc furnaces, we have developed a laboratory scale DC electric arc furnace presented in this paper. With the setup, optical emission spectra of Fe, Cr, Cr2O3, Ni, SiO2, Al2O3, CaO, and MgO were recorded in the wavelength range 250-600 nm and the results were analyzed with the help of reference data. The work demonstrates that using characteristic optical emission, obtaining in situ chemical information from oscillating plasma of electric arc furnaces is indeed possible. In spite of complications, the method could possibly be applied to industrial scale steel making process in order to improve its efficiency.

  11. Digitally tunable dual wavelength emission from semiconductor ring lasers with filtered optical feedback

    International Nuclear Information System (INIS)

    Khoder, Mulham; Verschaffelt, Guy; Nguimdo, Romain Modeste; Danckaert, Jan; Leijtens, Xaveer; Bolk, Jeroen

    2013-01-01

    We report on a novel integrated approach to obtain dual wavelength emission from a semiconductor laser based on on-chip filtered optical feedback. Using this approach, we show experiments and numerical simulations of dual wavelength emission of a semiconductor ring laser. The filtered optical feedback is realized on-chip by employing two arrayed waveguide gratings to split/recombine light into different wavelength channels. Semiconductor optical amplifiers are placed in the feedback loop in order to control the feedback strength of each wavelength channel independently. By tuning the current injected into each of the amplifiers, we can effectively cancel the gain difference between the wavelength channels due to fabrication and material dichroism, thus resulting in stable dual wavelength emission. We also explore the accuracy needed in the operational parameters to maintain this dual wavelength emission. (letter)

  12. End point detection in ion milling processes by sputter-induced optical emission spectroscopy

    International Nuclear Information System (INIS)

    Lu, C.; Dorian, M.; Tabei, M.; Elsea, A.

    1984-01-01

    The characteristic optical emission from the sputtered material during ion milling processes can provide an unambiguous indication of the presence of the specific etched species. By monitoring the intensity of a representative emission line, the etching process can be precisely terminated at an interface. Enhancement of the etching end point is possible by using a dual-channel photodetection system operating in a ratio or difference mode. The installation of the optical detection system to an existing etching chamber has been greatly facilitated by the use of optical fibers. Using a commercial ion milling system, experimental data for a number of etching processes have been obtained. The result demonstrates that sputter-induced optical emission spectroscopy offers many advantages over other techniques in detecting the etching end point of ion milling processes

  13. A comparative study of the enhancement of molecular emission in a spatially confined plume through optical emission spectroscopy and probe beam deflection measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Dayu; Liang, Peipei; Wu, Jiada; Xu, Ning; Ying, Zhifeng; Sun, Jian, E-mail: jsun@fudan.edu.cn

    2013-01-01

    The spatial confinement effects of shock wave on the expansion of a carbon plume induced by pulsed laser ablation of graphite in air and the enhancement of the plume emission were studied by optical emission spectroscopy and probe beam deflection measurements. A metal disk was set in the way of the ablation-generated shock wave to block and reflect the supersonically propagating shock wave. The reflected shock wave propagated backwards and confined the expanding plume. The optical emission of CN molecules was enhanced in contrast to the case without the block disk and the emission enhancement was dependent on the position of the disk. Based on the results of time-integrated and -resolved optical emission spectroscopy, and the time- and space-resolved probe beam deflection measurements, the processes occurring in the plume were discussed and the mechanisms responsible for the enhancement of molecular emission in the spatially confined plume were investigated. - Highlights: ► Spatial confinement and optical emission enhancement of carbon plume were studied. ► Ablation-generated shockwave propagating in air was reflected by a block disk. ► The effects of reflected shockwave on the emission enhancement were confirmed. ► The reflect shockwave confined the carbon plume and enhanced the plume emission.

  14. A comparative study of the enhancement of molecular emission in a spatially confined plume through optical emission spectroscopy and probe beam deflection measurements

    International Nuclear Information System (INIS)

    Ding, Dayu; Liang, Peipei; Wu, Jiada; Xu, Ning; Ying, Zhifeng; Sun, Jian

    2013-01-01

    The spatial confinement effects of shock wave on the expansion of a carbon plume induced by pulsed laser ablation of graphite in air and the enhancement of the plume emission were studied by optical emission spectroscopy and probe beam deflection measurements. A metal disk was set in the way of the ablation-generated shock wave to block and reflect the supersonically propagating shock wave. The reflected shock wave propagated backwards and confined the expanding plume. The optical emission of CN molecules was enhanced in contrast to the case without the block disk and the emission enhancement was dependent on the position of the disk. Based on the results of time-integrated and -resolved optical emission spectroscopy, and the time- and space-resolved probe beam deflection measurements, the processes occurring in the plume were discussed and the mechanisms responsible for the enhancement of molecular emission in the spatially confined plume were investigated. - Highlights: ► Spatial confinement and optical emission enhancement of carbon plume were studied. ► Ablation-generated shockwave propagating in air was reflected by a block disk. ► The effects of reflected shockwave on the emission enhancement were confirmed. ► The reflect shockwave confined the carbon plume and enhanced the plume emission

  15. Ultrafast spontaneous emission of copper-doped silicon enhanced by an optical nanocavity.

    Science.gov (United States)

    Sumikura, Hisashi; Kuramochi, Eiichi; Taniyama, Hideaki; Notomi, Masaya

    2014-05-23

    Dopants in silicon (Si) have attracted attention in the fields of photonics and quantum optics. However, the optical characteristics are limited by the small spontaneous emission rate of dopants in Si. This study demonstrates a large increase in the spontaneous emission rate of copper isoelectronic centres (Cu-IECs) doped into Si photonic crystal nanocavities. In a cavity with a quality factor (Q) of ~16,000, the photoluminescence (PL) lifetime of the Cu-IECs is 1.1 ns, which is 30 times shorter than the lifetime of a sample without a cavity. The PL decay rate is increased in proportion to Q/Vc (Vc is the cavity mode volume), which indicates the Purcell effect. This is the first demonstration of a cavity-enhanced ultrafast spontaneous emission from dopants in Si, and it may lead to the development of fast and efficient Si light emitters and Si quantum optical devices based on dopants with efficient optical access.

  16. Urinary nickel: measurement of exposure by inductively coupled plasma argon emission spectrometry.

    Science.gov (United States)

    Koizumi, Chisato; Usuda, Kan; Hayashi, Satsuki; Dote, Tomotaro; Kono, Koichi

    2004-09-01

    Nickel is a rare earth metal and is widely used in modern industry. Its overexposure in human beings can provoke significant effects including lung, cardiovascular and kidney diseases. As an index of occupational exposure, urine is widely used for the monitoring of nickel concentration because it is a minimally invasive method. Recent studies have used atomic absorption spectrometry to measure nickel concentration. In this study, we introduced novel inductively coupled plasma argon emission spectrometry (ICPAES) which enables us to measure multiple elements simultaneously with smaller volume and with lower detection limits compared to conventional atomic absorption emission spectrometry, and we established the new measuring method by determining the appropriate wavelengths for nickel concentration. Furthermore, using the established new measuring method, we investigated the correlation between a single oral administration of nickel and urine elimination in rats. As a result, different concentrations of nickel standard solutions were measured by ICPAES, and among five specific wavelengths of nickel, 221.647 and 231.604 nm were chosen because they had the highest inclines of both signal to background ratio and emission intensity in simple linear regression analysis. Next, by using healthy human urine samples that had not been exposed to nickel, 231.604 nm was determined to be the most appropriate wavelength because it did not present abnormal intensity due to obstacle wavelength. Male Wistar rats received an oral administration of nickel ranging from 0.025 to 250 mg/kg, which is equivalent to 0.0015 - 15% of LD50, and during the following 24 h, urine samples were collected and the nickel concentration was measured by ICPAES. With a single oral administration of nickel, there was an increase in urine nickel concentration in a dose-dependent manner and the appropriate equation was developed. Acute renal failure was not observed in this dosage of oral nickel

  17. Optical emission from laser-produced chromium and magnesium

    Indian Academy of Sciences (India)

    Optical emission from laser-produced chromium and magnesium plasma under the effect of two sequential laser pulses ... Laser Plasma Division, Centre for Advanced Technology, Indore 452 013, India; Diagnostic Instrumentation and Analysis Laboratory, Mississippi State University, 205 Research Boulevard, Starkville, ...

  18. Energy input and response from prompt and early optical afterglow emission in gamma-ray bursts.

    Science.gov (United States)

    Vestrand, W T; Wren, J A; Wozniak, P R; Aptekar, R; Golentskii, S; Pal'shin, V; Sakamoto, T; White, R R; Evans, S; Casperson, D; Fenimore, E

    2006-07-13

    The taxonomy of optical emission detected during the critical first few minutes after the onset of a gamma-ray burst (GRB) defines two broad classes: prompt optical emission correlated with prompt gamma-ray emission, and early optical afterglow emission uncorrelated with the gamma-ray emission. The standard theoretical interpretation attributes prompt emission to internal shocks in the ultra-relativistic outflow generated by the internal engine; early afterglow emission is attributed to shocks generated by interaction with the surrounding medium. Here we report on observations of a bright GRB that, for the first time, clearly show the temporal relationship and relative strength of the two optical components. The observations indicate that early afterglow emission can be understood as reverberation of the energy input measured by prompt emission. Measurements of the early afterglow reverberations therefore probe the structure of the environment around the burst, whereas the subsequent response to late-time impulsive energy releases reveals how earlier flaring episodes have altered the jet and environment parameters. Many GRBs are generated by the death of massive stars that were born and died before the Universe was ten per cent of its current age, so GRB afterglow reverberations provide clues about the environments around some of the first stars.

  19. Evaluation of slurry preparation procedures for the determination of mercury by axial view inductively coupled plasma optical emission spectrometry using on-line cold vapor generation

    International Nuclear Information System (INIS)

    Santos, Eder Jose dos; Herrmann, Amanda Beatriz; Antunes Vieira, Mariana; Azzolin Frescura, Vera Lucia; Curtius, Adilson Jose

    2005-01-01

    Five different slurry preparation procedures were tested, after grinding the solid samples to a particle size ≤53 μm: (1) using aqua regia plus HF, 30 min of sonication, standing time of 24 h followed by another 30 min of sonication; (2) same as the previous one, except that the standing time and the second ultrasound treatment were omitted; (3) same as the previous one, except that HF was not used; (4) same as the previous one, except that the aqua regia was replaced by nitric acid; (5) same as the previous one, except that the acid nitric was replaced by tetramethylammonium hydroxide (TMAH). The Hg vapor was generated on-line, and the emission signal intensity measured at 253.652 nm by axial view inductively coupled plasma optical emission spectrometry. Initially, four experimental conditions were optimized using a multivariate factorial analysis: the concentrations of HCl and of the reducing agent, NaBH 4 , used in the cold vapor generation, and two instrumental parameters, the plasma radiofrequency power and the carrier gas flow rate. The radiofrequency power was statistically significant, but limited to 1.2 kW for practical reasons. The procedures were applied to 11 biological and environmental materials. Both, the slurries and the filtrates were analyzed, using calibration solutions in the same medium as in the slurries. The first three procedures produced results in agreement with the certified values. The two last procedures, using nitric acid or TMHA could not be used for quantitative analysis. For practical reasons, Procedure 3, with a detection limit (3s, n=10) of 0.06 μg g -1 for a sample mass of 20 mg in a final volume of 15 mL is recommended. The relative standard deviations for mercury in the investigated materials, using the recommended procedure, were lower than 12.5%, indicating a good precision for slurry sampling. The recommended procedure is simple, rapid and robust

  20. An isotopic analysis process with optical emission spectrometry on a laser-produced plasma

    International Nuclear Information System (INIS)

    Mauchien, P.; Pietsch, W.; Petit, A.; Briand, A.

    1994-01-01

    The sample that is to be analyzed is irradiated with a laser beam to produce a plasma at the sample surface; the spectrum of the light emitted by the plasma is analyzed and the isotope composition of the sample is derived from the spectrometry. The process is preferentially applied to uranium and plutonium; it is rapid, simpler and cheaper than previous methods, and may be applied to 'in-situ' isotopic analysis in nuclear industry. 2 figs

  1. Thermal tuning of spectral emission from optically trapped liquid-crystal droplet resonators

    Czech Academy of Sciences Publication Activity Database

    Jonáš, A.; Pilát, Zdeněk; Ježek, Jan; Bernatová, Silvie; Fořt, Tomáš; Zemánek, Pavel; Aas, M.; Kiraz, A.

    2017-01-01

    Roč. 34, č. 9 (2017), s. 1855-1864 ISSN 0740-3224 R&D Projects: GA MŠk(CZ) LD14069; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : emission spectroscopy * drops * optical tweezers Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 1.843, year: 2016

  2. Evaluation of a new optic-enabled portable X-ray fluorescence spectrometry instrument for measuring toxic metals/metalloids in consumer goods and cultural products

    Science.gov (United States)

    Guimarães, Diana; Praamsma, Meredith L.; Parsons, Patrick J.

    2016-08-01

    X-ray fluorescence spectrometry (XRF) is a rapid, non-destructive multi-elemental analytical technique used for determining elemental contents ranging from percent down to the μg/g level. Although detection limits are much higher for XRF compared to other laboratory-based methods, such as inductively coupled plasma mass spectrometry (ICP-MS), ICP-optical emission spectrometry (OES) and atomic absorption spectrometry (AAS), its portability and ease of use make it a valuable tool, especially for field-based studies. A growing necessity to monitor human exposure to toxic metals and metalloids in consumer goods, cultural products, foods and other sample types while performing the analysis in situ has led to several important developments in portable XRF technology. In this study, a new portable XRF analyzer based on the use of doubly curved crystal optics (HD Mobile®) was evaluated for detecting toxic elements in foods, medicines, cosmetics and spices used in many Asian communities. Two models of the HD Mobile® (a pre-production and a final production unit) were investigated. Performance parameters including accuracy, precision and detection limits were characterized in a laboratory setting using certified reference materials (CRMs) and standard solutions. Bias estimates for key elements of public health significance such as As, Cd, Hg and Pb ranged from - 10% to 11% for the pre-production, and - 14% to 16% for the final production model. Five archived public health samples including herbal medicine products, ethnic spices and cosmetic products were analyzed using both XRF instruments. There was good agreement between the pre-production and final production models for the four key elements, such that the data were judged to be fit-for-purpose for the majority of samples analyzed. Detection of the four key elements of interest using the HD Mobile® was confirmed using archived samples for which ICP-OES data were available based on digested sample materials. The HD

  3. Ion induced optical emission for surface and depth profile analysis

    International Nuclear Information System (INIS)

    White, C.W.

    1977-01-01

    Low-energy ion bombardment of solid surfaces results in the emission of infrared, visible, and ultraviolet radiation produced by inelastic ion-solid collision processes. The emitted optical radiation provides important insight into low-energy particle-solid interactions and provides the basis for an analysis technique which can be used for surface and depth profile analysis with high sensitivity. The different kinds of collision induced optical radiation emitted as a result of low-energy particle-solid collisions are reviewed. Line radiation arising from excited states of sputtered atoms or molecules is shown to provide the basis for surface and depth profile analysis. The spectral characteristics of this type of radiation are discussed and applications of the ion induced optical emission technique are presented. These applications include measurements of ion implant profiles, detection sensitivities for submonolayer quantities of impurities on elemental surfaces, and the detection of elemental impurities on complex organic substrates

  4. Optical emission of InAs nanowires

    International Nuclear Information System (INIS)

    Möller, M; De Lima Jr, M M; Cantarero, A; Chiaramonte, T; Cotta, M A; Iikawa, F

    2012-01-01

    Wurtzite InAs nanowire samples grown by chemical beam epitaxy have been analyzed by photoluminescence spectroscopy. The nanowires exhibit two main optical emission bands at low temperatures. They are attributed to the recombination of carriers in quantum well structures, formed by zincblende–wurtzite alternating layers, and to the donor–acceptor pair. The blue-shift observed in the former emission band when the excitation power is increased is in good agreement with the type-II band alignment between the wurtzite and zincblende sections predicted by previous theoretical works. When increasing the temperature and the excitation power successively, an additional band attributed to the band-to-band recombination from wurtzite InAs appears. We estimated a lower bound for the wurtzite band gap energy of approximately 0.46 eV at low temperature. (paper)

  5. Optical emission of InAs nanowires

    Science.gov (United States)

    Möller, M.; de Lima, M. M., Jr.; Cantarero, A.; Chiaramonte, T.; Cotta, M. A.; Iikawa, F.

    2012-09-01

    Wurtzite InAs nanowire samples grown by chemical beam epitaxy have been analyzed by photoluminescence spectroscopy. The nanowires exhibit two main optical emission bands at low temperatures. They are attributed to the recombination of carriers in quantum well structures, formed by zincblende-wurtzite alternating layers, and to the donor-acceptor pair. The blue-shift observed in the former emission band when the excitation power is increased is in good agreement with the type-II band alignment between the wurtzite and zincblende sections predicted by previous theoretical works. When increasing the temperature and the excitation power successively, an additional band attributed to the band-to-band recombination from wurtzite InAs appears. We estimated a lower bound for the wurtzite band gap energy of approximately 0.46 eV at low temperature.

  6. X-mode artificial optical emissions and attendant phenomena at EISCAT/Heating

    Science.gov (United States)

    Blagoveshchenskaya, Nataly; Sergienko, Tima; Rietveld, Michael; Brandstrom, Urban; Senior, Andrew; Haggstrom, Ingemar; Kosch, Michael; Borisova, Tatiana; Yeoman, Tim

    We present the experimental evidence for the formation of the artificial optical emissions induced by the X-mode powerful HF radio waves injected towards the magnetic zenith (MZ) into the high latitude F region of the ionosphere. The experiments were conducted in the course of Russian EISCAT heating campaigns in October 2012 and October 2013 at the Heating facility at Tromsø, Norway. The HF pump wave with the X-mode polarization was radiated at 7.1 or 6.2 MHz. The phased array 1, resulting in an ERP = 430 - 600 MW was used. Optical emissions at red (630 nm) and green (557 nm) lines were imaged from Tromsø site by the digital All-Sky Imager mark 2 (DASI - 2) and from a remote site at Abisco by the Auroral Large Imaging System (ALIS) in Scandinavia. The intensities of X-mode emissions at red and green lines varied between about of 150 - 1000 R and 50 - 300 R above the background respectively in different experiments. The artificial optical emissions were accompanied by very strong HF-enhanced ion lines and HF induced plasma lines from the EISCAT UHF incoherent scatter radar measurements and artificial small-scale field-aligned irregularities from CUTLASS (SuperDARN) HF coherent radar in Finland. The results obtained are discussed.

  7. Early optical emission from the gamma-ray burst of 4 October 2002.

    Science.gov (United States)

    Fox, D W; Yost, S; Kulkarni, S R; Torii, K; Kato, T; Yamaoka, H; Sako, M; Harrison, F A; Sari, R; Price, P A; Berger, E; Soderberg, A M; Djorgovski, S G; Barth, A J; Pravdo, S H; Frail, D A; Gal-Yam, A; Lipkin, Y; Mauch, T; Harrison, C; Buttery, H

    2003-03-20

    Observations of the long-lived emission--or 'afterglow'--of long-duration gamma-ray bursts place them at cosmological distances, but the origin of these energetic explosions remains a mystery. Observations of optical emission contemporaneous with the burst of gamma-rays should provide insight into the details of the explosion, as well as into the structure of the surrounding environment. One bright optical flash was detected during a burst, but other efforts have produced negative results. Here we report the discovery of the optical counterpart of GRB021004 only 193 seconds after the event. The initial decline is unexpectedly slow and requires varying energy content in the gamma-ray burst blastwave over the course of the first hour. Further analysis of the X-ray and optical afterglow suggests additional energy variations over the first few days.

  8. High Spatial Resolution Imaging Mass Spectrometry of Human Optic Nerve Lipids and Proteins

    Science.gov (United States)

    Anderson, David M. G.; Spraggins, Jeffrey M.; Rose, Kristie L.; Schey, Kevin L.

    2015-06-01

    The human optic nerve carries signals from the retina to the visual cortex of the brain. Each optic nerve is comprised of approximately one million nerve fibers that are organized into bundles of 800-1200 fibers surrounded by connective tissue and supportive glial cells. Damage to the optic nerve contributes to a number of blinding diseases including: glaucoma, neuromyelitis optica, optic neuritis, and neurofibromatosis; however, the molecular mechanisms of optic nerve damage and death are incompletely understood. Herein we present high spatial resolution MALDI imaging mass spectrometry (IMS) analysis of lipids and proteins to define the molecular anatomy of the human optic nerve. The localization of a number of lipids was observed in discrete anatomical regions corresponding to myelinated and unmyelinated nerve regions as well as to supporting connective tissue, glial cells, and blood vessels. A protein fragment from vimentin, a known intermediate filament marker for astrocytes, was observed surrounding nerved fiber bundles in the lamina cribrosa region. S100B was also found in supporting glial cell regions in the prelaminar region, and the hemoglobin alpha subunit was observed in blood vessel areas. The molecular anatomy of the optic nerve defined by MALDI IMS provides a firm foundation to study biochemical changes in blinding human diseases.

  9. Correlated optical and isotopic nanoscopy

    Science.gov (United States)

    Saka, Sinem K.; Vogts, Angela; Kröhnert, Katharina; Hillion, François; Rizzoli, Silvio O.; Wessels, Johannes T.

    2014-04-01

    The isotopic composition of different materials can be imaged by secondary ion mass spectrometry. In biology, this method is mainly used to study cellular metabolism and turnover, by pulsing the cells with marker molecules such as amino acids labelled with stable isotopes (15N, 13C). The incorporation of the markers is then imaged with a lateral resolution that can surpass 100 nm. However, secondary ion mass spectrometry cannot identify specific subcellular structures like organelles, and needs to be correlated with a second technique, such as fluorescence imaging. Here, we present a method based on stimulated emission depletion microscopy that provides correlated optical and isotopic nanoscopy (COIN) images. We use this approach to study the protein turnover in different organelles from cultured hippocampal neurons. Correlated optical and isotopic nanoscopy can be applied to a variety of biological samples, and should therefore enable the investigation of the isotopic composition of many organelles and subcellular structures.

  10. Cadmium, copper, lead, and zinc determination in precipitation: A comparison of inductively coupled plasma atomic emission spectrometry and graphite furnace atomization atomic absorption spectrometry

    Science.gov (United States)

    Reddy, M.M.; Benefiel, M.A.; Claassen, H.C.

    1987-01-01

    Selected trace element analysis for cadmium, copper, lead, and zinc in precipitation samples by inductively coupled plasma atomic emission Spectrometry (ICP) and by atomic absorption spectrometry with graphite furnace atomization (AAGF) have been evaluated. This task was conducted in conjunction with a longterm study of precipitation chemistry at high altitude sites located in remote areas of the southwestern United States. Coefficients of variation and recovery values were determined for a standard reference water sample for all metals examined for both techniques. At concentration levels less than 10 micrograms per liter AAGF analyses exhibited better precision and accuracy than ICP. Both methods appear to offer the potential for cost-effective analysis of trace metal ions in precipitation. ?? 1987 Springer-Verlag.

  11. New high temperature plasmas and sample introduction systems for analytical atomic emission and mass spectrometry

    International Nuclear Information System (INIS)

    Montaser, A.

    1993-01-01

    In this research, new high-temperature plasmas and new sample introduction systems are explored for rapid elemental and isotopic analysis of gases, solutions, and solids using mass spectrometry and atomic emission spectrometry. During the period January 1993--December 1993, emphasis was placed on (a) analytical investigations of atmospheric-pressure helium inductively coupled plasma (He ICP) that are suitable for atomization, excitation, and ionization of elements possessing high excitation and ionization energies; (b) simulation and computer modeling of plasma sources to predict their structure and fundamental and analytical properties without incurring the enormous cost of experimental studies; (c) spectrosopic imaging and diagnostic studies of high-temperature plasmas; (d) fundamental studies of He ICP discharges and argon-nitrogen plasma by high-resolution Fourier transform spectrometry; and (e) fundamental and analytical investigation of new, low-cost devices as sample introduction systems for atomic spectrometry and examination of new diagnostic techniques for probing aerosols. Only the most important achievements are included in this report to illustrate progress and obstacles. Detailed descriptions of the authors' investigations are outlined in the reprints and preprints that accompany this report. The technical progress expected next year is briefly described at the end of this report

  12. Generalized dispersive wave emission in nonlinear fiber optics.

    Science.gov (United States)

    Webb, K E; Xu, Y Q; Erkintalo, M; Murdoch, S G

    2013-01-15

    We show that the emission of dispersive waves in nonlinear fiber optics is not limited to soliton-like pulses propagating in the anomalous dispersion regime. We demonstrate, both numerically and experimentally, that pulses propagating in the normal dispersion regime can excite resonant dispersive radiation across the zero-dispersion wavelength into the anomalous regime.

  13. Determination of Pt, Pd and Rh in Brassica Napus using solid sampling electrothermal vaporization inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Nischkauer, Winfried; Herincs, Esther; Puschenreiter, Markus; Wenzel, Walter; Limbeck, Andreas

    2013-01-01

    Conventional approaches for the analysis of platinum group elements (PGEs) in plant material suffer from sample digestion which results in sample dilution and therefore requires high sample intakes to maintain the sensitivity. The presented solid-sampling method avoids sample digestion while improving sensitivity when compared to digestion-based inductively coupled plasma optical emission spectrometry (ICP-OES) methods and allows the analysis of sample masses of 5 mg or less. Detection limits of 0.38 μg g −1 , 0.14 μg g −1 and 0.13 μg g −1 were obtained for Pt, Pd and Rh, respectively using a sample intake of 5 mg. The reproducibility of the procedure ranged between 4.7% (Pd) relative standard deviation (RSD, n = 7) and 7.1% (Rh) RSD for 25 ng analytes. For quantification, aqueous standards were applied on paper filter strips and dried. Only the dried filters were introduced into the electrothermal vaporization unit. This approach successfully removed memory-effects observed during analysis of platinum which occurred only if liquid standards came into contact with the graphite material of the furnace. The presented method for overcoming the Pt-memory-effects may be of further interest for the analysis of other carbide-forming analytes as it does not require any technical modification of the graphite furnace (e.g., metal inlays, pyrolytic coating). Owing to lack of suitable certified reference materials, the proposed method was compared with conventional ICP-OES analysis of digested samples and a good agreement was obtained. As a result of the low sample consumption, it was possible to determine the spatial distribution of PGEs within a single plant. Significant differences in PGE concentrations were observed between the shoots (stem, leaves) and the roots. Pd was mainly found in the roots, whereas Pt and Rh were also found in higher concentrations in the shoots. - Highlights: • The uptake of Pt, Pd and Rh by hydroponically grown plants was investigated

  14. Determination of Pt, Pd and Rh in Brassica Napus using solid sampling electrothermal vaporization inductively coupled plasma optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Nischkauer, Winfried [Vienna University of Technology, Institute of Chemical Technologies and Analytics, Division of Instrumental Analytical Chemistry, Getreidemarkt 9/164-IAC, A-1060 Vienna (Austria); Herincs, Esther [Vienna University of Technology, Institute of Chemical Technologies and Analytics, Division of Instrumental Analytical Chemistry, Getreidemarkt 9/164-IAC, A-1060 Vienna (Austria); University of Natural Resources and Life Sciences, Department of Forest and Soil Sciences, Institute of Soil Research, Konrad Lorenz Straße 24, A-3430 Tulln (Austria); Puschenreiter, Markus; Wenzel, Walter [University of Natural Resources and Life Sciences, Department of Forest and Soil Sciences, Institute of Soil Research, Konrad Lorenz Straße 24, A-3430 Tulln (Austria); Limbeck, Andreas, E-mail: A.Limbeck@tuwien.ac.at [Vienna University of Technology, Institute of Chemical Technologies and Analytics, Division of Instrumental Analytical Chemistry, Getreidemarkt 9/164-IAC, A-1060 Vienna (Austria)

    2013-11-01

    Conventional approaches for the analysis of platinum group elements (PGEs) in plant material suffer from sample digestion which results in sample dilution and therefore requires high sample intakes to maintain the sensitivity. The presented solid-sampling method avoids sample digestion while improving sensitivity when compared to digestion-based inductively coupled plasma optical emission spectrometry (ICP-OES) methods and allows the analysis of sample masses of 5 mg or less. Detection limits of 0.38 μg g{sup −1}, 0.14 μg g{sup −1} and 0.13 μg g{sup −1} were obtained for Pt, Pd and Rh, respectively using a sample intake of 5 mg. The reproducibility of the procedure ranged between 4.7% (Pd) relative standard deviation (RSD, n = 7) and 7.1% (Rh) RSD for 25 ng analytes. For quantification, aqueous standards were applied on paper filter strips and dried. Only the dried filters were introduced into the electrothermal vaporization unit. This approach successfully removed memory-effects observed during analysis of platinum which occurred only if liquid standards came into contact with the graphite material of the furnace. The presented method for overcoming the Pt-memory-effects may be of further interest for the analysis of other carbide-forming analytes as it does not require any technical modification of the graphite furnace (e.g., metal inlays, pyrolytic coating). Owing to lack of suitable certified reference materials, the proposed method was compared with conventional ICP-OES analysis of digested samples and a good agreement was obtained. As a result of the low sample consumption, it was possible to determine the spatial distribution of PGEs within a single plant. Significant differences in PGE concentrations were observed between the shoots (stem, leaves) and the roots. Pd was mainly found in the roots, whereas Pt and Rh were also found in higher concentrations in the shoots. - Highlights: • The uptake of Pt, Pd and Rh by hydroponically grown plants was

  15. Process control with optical emission spectroscopy in triode ion plating

    International Nuclear Information System (INIS)

    Salmenoja, K.; Korhonen, A.S.; Sulonen, M.S.

    1985-01-01

    Physical vapor deposition (PVD) techniques used to prepare, e.g., hard TiN, HfN, or ZrN coatings include a great variety of processes ranging from reactive evaporation to sputtering and ion plating. In ion plating one effective way to enhance ionization is to use a negatively biased hot filament. The use of an electron emitting filament brings an extra variable to be taken into account in developing the process control. In addition, proper control of the evaporation source is critical in ensuring reproducible results. With optical emission spectroscopy (OES) it should be possible to control the coating process more accurately. The stoichiometry and the composition of the growing coating may then be ensured effectively in subsequent runs. In this work the application of optical emission spectroscopy for process control in triode ion plating is discussed. The composition of the growing coating is determined experimentally using the relative intensities of specific emission lines. Changes in the evaporation rate and the gas flow can be seen directly from emission line intensities. Even the so-called poisoning of the evaporation source with reactive gas can be detected. Several experimental runs were carried out and afterwards the concentration profiles of the deposited coatings were checked with the nuclear resonance broadening (NRB) method. The results show the usefulness of emission spectroscopy in discharge control

  16. Detection of negative ions in glow discharge mass spectrometry for analysis of solid specimens

    DEFF Research Database (Denmark)

    Canulescu, Stela; Molchan, Igor S.; Tauziede, C.

    2010-01-01

    A new method is presented for elemental and molecular analysis of halogen-containing samples by glow discharge time-of-flight mass spectrometry, consisting of detection of negative ions from a pulsed RF glow discharge in argon. Analyte signals are mainly extracted from the afterglow regime...... be used to study the distribution of a tantalum fluoride layer within the anodized tantala layer. Further, comparison is made with data obtained using glow-discharge optical emission spectroscopy, where elemental fluorine can only be detected using a neon plasma. The ionization mechanisms responsible...... for the formation of negative ions in glow discharge time-of-flight mass spectrometry are briefly discussed....

  17. Study of the hydrolysis reaction of the copper-chloride hybrid thermochemical cycle using optical spectrometries

    International Nuclear Information System (INIS)

    Doizi, D.; Borgard, J.M.; Dauvois, V.; Roujou, J.L.; Zanella, Y.; Croize, L.; Cartes, Ph.; Hartmann, J.M.

    2010-01-01

    The copper-chloride hybrid thermochemical cycle is one of the best potential low temperature thermochemical cycles for the massive production of hydrogen. It could be used with nuclear reactors such as the sodium fast reactor or the supercritical water reactor. Nevertheless, this thermochemical cycle is composed of an electrochemical reaction and two thermal reactions. Its efficiency has to be compared with other hydrogen production processes like alkaline electrolysis for example. The purpose of this article is to study the viability of the copper chloride thermochemical cycle by studying the hydrolysis reaction of CuCl 2 which is not favoured thermodynamically. To better understand the occurrence of possible side reactions, together with a good control of the kinetics of the hydrolysis reaction, the use of optical absorption spectrometries, UV visible spectrometry to detect molecular chlorine which may be formed in side reactions, FTIR spectrometry to follow the concentrations of H 2 O and HCl is proposed. (authors)

  18. On the relationship between optical and radio emission from active galaxy nuclei

    International Nuclear Information System (INIS)

    Zentsova, A.S.; Fedorenko, V.N.

    1991-01-01

    Model in which the radio emission of nuclei of Seyfert galaxies emerges in the regions of formation of their narrow emission lines, R∼100 pc is developed. Gaseous clouds, producing this emission, are moving in the surrounding hot gas and induce shock waves. The shock waves accelerate electrons, which produce radio emission via synchrotron mechanism. The model explains an observational correlation between the radio and optical properties of Seyfert galaxies and makes some predictions on the parameters of the region R∼100 pc

  19. Optical bistability via quantum interference from incoherent pumping and spontaneous emission

    International Nuclear Information System (INIS)

    Sahrai, M.; Asadpour, S.H.; Sadighi-Bonabi, R.

    2011-01-01

    We theoretically investigate the optical bistability (OB) in a V-type three-level atomic system confined in a unidirectional ring cavity via incoherent pumping field. It is shown that the threshold of optical bistability can be controlled by the rate of an incoherent pumping field and by interference mechanism arising from the spontaneous emission and incoherent pumping field. We demonstrate that the optical bistability converts to optical multi-stability (OM) by the quantum interference mechanism. - Highlights: → We modulate the optical bistability (OB) in a four-level N-type atomic system. → The threshold of optical bistability can be controlled by the quantum interferences. → OB converts to optical multi-stability (OM) by the quantum interferences. → We discuss the effect of an incoherent pumping field on reduction of OB threshold.

  20. N-15 analysis by emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-12-31

    The stable isotope of nitrogen, N-15, has become widely used as tracer in agriculture, medicine and biology research. The film gives an overview of the sample preparation and analytical procedures followed in the analysis of the nitrogen isotopic composition (14N/15N ratio) by optical emission spectrometry at the Seibersdorf Laboratory. The subsampling of plant material and the several steps of chemical pretreatment such as Kjeldahl digestion, distillation, titration and adjustment of the proper N concentration in the extract are demonstrated. The preparation of the discharge tubes is shown in detail. Final measurement of the 14N/15N ratio is carried out with the NOI-5 and JASCO emission spectrometers

  1. Alpha-particle emission probabilities of ²³⁶U obtained by alpha spectrometry.

    Science.gov (United States)

    Marouli, M; Pommé, S; Jobbágy, V; Van Ammel, R; Paepen, J; Stroh, H; Benedik, L

    2014-05-01

    High-resolution alpha-particle spectrometry was performed with an ion-implanted silicon detector in vacuum on a homogeneously electrodeposited (236)U source. The source was measured at different solid angles subtended by the detector, varying between 0.8% and 2.4% of 4π sr, to assess the influence of coincidental detection of alpha-particles and conversion electrons on the measured alpha-particle emission probabilities. Additional measurements were performed using a bending magnet to eliminate conversion electrons, the results of which coincide with normal measurements extrapolated to an infinitely small solid angle. The measured alpha emission probabilities for the three main peaks - 74.20 (5)%, 25.68 (5)% and 0.123 (5)%, respectively - are consistent with literature data, but their precision has been improved by at least one order of magnitude in this work. © 2013 Published by Elsevier Ltd.

  2. Scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDX) and aerosol time-of-flight mass spectrometry (ATOFMS) single particle analysis of metallurgy plant emissions.

    Science.gov (United States)

    Arndt, J; Deboudt, K; Anderson, A; Blondel, A; Eliet, S; Flament, P; Fourmentin, M; Healy, R M; Savary, V; Setyan, A; Wenger, J C

    2016-03-01

    The chemical composition of single particles deposited on industrial filters located in three different chimneys of an iron-manganese (Fe-Mn) alloy manufacturing plant have been compared using aerosol time-of-flight mass spectrometry (ATOFMS) and scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDX). Very similar types of particles were observed using both analytical techniques. Calcium-containing particles dominated in the firing area of the sintering unit, Mn and/or Al-bearing particles were observed at the cooling area of the sintering unit, while Mn-containing particles were dominant at the smelting unit. SEM-EDX analysis of particles collected downstream of the industrial filters showed that the composition of the particles emitted from the chimneys is very similar to those collected on the filters. ATOFMS analysis of ore samples was also performed to identify particulate emissions that could be generated by wind erosion and manual activities. Specific particle types have been identified for each emission source (chimneys and ore piles) and can be used as tracers for source apportionment of ambient PM measured in the vicinity of the industrial site. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Lithium determination in whole blood by flame atomic emission spectrometry

    International Nuclear Information System (INIS)

    Rahman, S.; Khalid, N.; Nasimullah; Iqbal, M.Z.

    2003-01-01

    A simple and rapid method for the determination of lithium in whole blood using Flame atomic emission spectrometry is described. No sample preparation was required apart from dilution with 0.02 N HNO/sub 3/. The reliability of the method was determined by analyzing Standard Reference Material (SRM) under identical experimental conditions and comparing the determined lithium concentration with the reported value. These were in good agreement with each other. The determined range of lithium in the whole blood of fifty-six healthy adult volunteers (28 males and 28 females) were 13.1 - 47.8 mg L-1. The determined average concentration of lithium in whole blood was compared with the reported values of other countries. The data was statistically analyzed with respect to sex and different age groups. (author)

  4. Determination of trace elements in maifanite by outer cover electrode atomic emission spectrometry

    Institute of Scientific and Technical Information of China (English)

    LI Jianqiang; LU Yiqiang; JIANG Wei

    2005-01-01

    Maifanite is a nature medicinal stone used in many fields for long time. The research on it showed that there are many trace elements in maifanite. In this paper, 36 trace elements in maifanite were determined by outer cover electrode atomic emission spectrometry, and the determination conditions were studied systematically. The results show that the concentrafions of elements, which are beneficial to human health, are higher, and the elements harmful to people health such as As, Cd, Hg, Cr, and Pb are tiny in maifanite. The precision and the accuracy were also discussed.

  5. Optical emissions associated with energetic electrons produced by stepping leaders in cloud-to-ground lightning discharges

    OpenAIRE

    Xu , Wei; Celestin , Sebastien; Pasko , Victor

    2015-01-01

    All data used in this paper are directly available after a request is made to authors W.X. (), S.C. (), or V.P.P. ().; International audience; Both natural cloud-to-ground and rocket-triggered lightning flashes have been found to be associated with intense and brief bursts of X-ray emissions. Using a full energy Monte Carlo model combined with an optical emission model, we quantify the optical emissions induced by the strong accel...

  6. Optical fibers for remote spectrometry of alkali elements in the dc arc

    International Nuclear Information System (INIS)

    Faires, L.M.; Bieniewski, T.M.; Apel, C.T.; Niemczyk, T.M.

    1985-01-01

    An optical fiber cable is designed, characterized, and applied to the remote spectrometric analysis of alkali elements as impurities in plutonium by dc arc emission. The analytical performance of the dc arc/optical fiber/polychromator system is tested by the establishment of analytical working curves for sodium, potassium, and rubidium from a set of standards. Accuracy, determined by the use of control samples of known concentration, is found to be 10% or better. The new analytical system provides improvement in both accuracy and efficiency compared to the previously used spectrographic technique

  7. Phenomenology of reverse-shock emission in the optical afterglows of gamma-ray bursts

    International Nuclear Information System (INIS)

    Japelj, J.; Kopač, D.; Gomboc, A.; Kobayashi, S.; Harrison, R.; Virgili, F. J.; Mundell, C. G.; Guidorzi, C.; Melandri, A.

    2014-01-01

    We use a parent sample of 118 gamma-ray burst (GRB) afterglows, with known redshift and host galaxy extinction, to separate afterglows with and without signatures of dominant reverse-shock (RS) emission and to determine which physical conditions lead to a prominent reverse-shock emission. We identify 10 GRBs with reverse-shock signatures: 990123, 021004, 021211, 060908, 061126, 080319B, 081007, 090102, 090424, and 130427A. By modeling their optical afterglows with reverse- and forward-shock analytic light curves and using Monte Carlo simulations, we estimate the parameter space of the physical quantities describing the ejecta and circumburst medium. We find that physical properties cover a wide parameter space and do not seem to cluster around any preferential values. Comparing the rest-frame optical, X-ray, and high-energy properties of the larger sample of non-RS-dominated GRBs, we show that the early-time (<1 ks) optical spectral luminosity, X-ray afterglow luminosity, and γ-ray energy output of our reverse-shock dominated sample do not differ significantly from the general population at early times. However, the GRBs with dominant reverse-shock emission have fainter than average optical forward-shock emission at late times (>10 ks). We find that GRBs with an identifiable reverse-shock component show a high magnetization parameter R B = ε B,r /ε B,f ∼ 2-10 4 . Our results are in agreement with the mildly magnetized baryonic jet model of GRBs.

  8. Simultaneous preconcentration of copper, zinc, cadmium, and nickel in water samples by cloud point extraction using 4-(2-pyridylazo)-resorcinol and their determination by inductively coupled plasma optic emission spectrometry

    International Nuclear Information System (INIS)

    Silva, Edson Luiz; Santos Roldan, Paulo dos; Gine, Maria Fernanda

    2009-01-01

    A procedure for simultaneous separation/preconcentration of copper, zinc, cadmium, and nickel in water samples, based on cloud point extraction (CPE) as a prior step to their determination by inductively coupled plasma optic emission spectrometry (ICP-OES), has been developed. The analytes reacted with 4-(2-pyridylazo)-resorcinol (PAR) at pH 5 to form hydrophobic chelates, which were separated and preconcentrated in a surfactant-rich phase of octylphenoxypolyethoxyethanol (Triton X-114). The parameters affecting the extraction efficiency of the proposed method, such as sample pH, complexing agent concentration, buffer amount, surfactant concentration, temperature, kinetics of complexation reaction, and incubation time were optimized and their respective values were 5, 0.6 mmol L -1 , 0.3 mL, 0.15% (w/v), 50 deg. C, 40 min, and 10 min for 15 mL of preconcentrated solution. The method presented precision (R.S.D.) between 1.3% and 2.6% (n = 9). The concentration factors with and without dilution of the surfactant-rich phase for the analytes ranged from 9.4 to 10.1 and from 94.0 to 100.1, respectively. The limits of detection (L.O.D.) obtained for copper, zinc, cadmium, and nickel were 1.2, 1.1, 1.0, and 6.3 μg L -1 , respectively. The accuracy of the procedure was evaluated through recovery experiments on aqueous samples.

  9. Comparison in the analytical performance between krypton and argon glow discharge plasmas as the excitation source for atomic emission spectrometry.

    Science.gov (United States)

    Wagatsuma, Kazuaki

    2009-04-01

    The emission characteristics of ionic lines of nickel, cobalt, and vanadium were investigated when argon or krypton was employed as the plasma gas in glow discharge optical emission spectrometry. A dc Grimm-style lamp was employed as the excitation source. Detection limits of the ionic lines in each iron-matrix alloy sample were compared between the krypton and the argon plasmas. Particular intense ionic lines were observed in the emission spectra as a function of the discharge gas (krypton or argon), such as the Co II 258.033 nm for krypton and the Co II 231.707 nm for argon. The explanation for this is that collisions with the plasma gases dominantly populate particular excited levels of cobalt ion, which can receive the internal energy from each gas ion selectively, for example, the 3d(7)4p (3)G(5) (6.0201 eV) for krypton and the 3d(7)4p (3)G(4) (8.0779 eV) for argon. In the determination of nickel as well as cobalt in iron-matrix samples, more sensitive ionic lines could be found in the krypton plasma rather than the argon plasma. Detection limits in the krypton plasma were 0.0039 mass% Ni for the Ni II 230.299-nm line and 0.002 mass% Co for the Co II 258.033-nm line. However, in the determination of vanadium, the argon plasma had better analytical performance, giving a detection limit of 0.0023 mass% V for the V II 309.310-nm line.

  10. Application of cotton as a solid phase extraction sorbent for on-line preconcentration of copper in water samples prior to inductively coupled plasma optical emission spectrometry determination.

    Science.gov (United States)

    Faraji, Mohammad; Yamini, Yadollah; Shariati, Shahab

    2009-07-30

    Copper, as a heavy metal, is toxic for many biological systems. Thus, the determination of trace amounts of copper in environmental samples is of great importance. In the present work, a new method was developed for the determination of trace amounts of copper in water samples. The method is based on the formation of ternary Cu(II)-CAS-CTAB ion-pair and adsorption of it into a mini-column packed with cotton prior applying inductively coupled plasma optical emission spectrometry (ICP-OES). The experimental parameters that affected the extraction efficiency of the method such as pH, flow rate and volume of the sample solution, concentration of chromazurol S (CAS) and cethyltrimethylammonium bromide (CTAB) as well as type and concentration of eluent were investigated and optimized. The ion-pair (Cu(II)-CAS-CTAB) was quantitatively retained on the cotton under the optimum conditions, then eluted completely using a solution of 25% (v/v) 1-propanol in 0.5 mol L(-1) HNO(3) and directly introduced into the nebulizer of the ICP-OES. The detection limit (DL) of the method for copper was 40 ng L(-1) (V(sample)=100mL) and the relative standard deviation (R.S.D.) for the determination of copper at 10 microg L(-1) level was found to be 1.3%. The method was successfully applied to determine the trace amounts of copper in tap water, deep well water, seawater and two different mineral waters, and suitable recoveries were obtained (92-106%).

  11. Optical Emissions of Sprite Streamers in Weak Electric Fields

    Science.gov (United States)

    Liu, N.; Pasko, V. P.

    2004-12-01

    Sprites commonly consist of large numbers of needle-shaped filaments of ionization [e.g., Gerken and Inan, JASTP, 65, 567, 2003] and typically initiate at altitudes 70-75 km in a form of upward and downward propagating streamers [Stanley et al., GRL, 26, 3201, 1999; Stenbaek-Nielsen et al., GRL, 27, 3829, 2000; McHarg et al., JGR, 107, 1364, 2002; Moudry et al., JASTP, 65, 509, 2003]. The strong electric fields E exceeding the conventional breakdown threshold field Ek are needed for initiation of sprite streamers from single electron avalanches and recent modeling studies indicate that streamers propagating in fields E>Ek experience strong acceleration and expansion in good agreement with the above cited observations [Liu and Pasko, JGR, 109, A04301, 2004]. The initiated streamers are capable of propagating in fields substantially lower than Ek [Allen and Ghaffar, J. Phys. D: Appl. Phys., 28, 331, 1995] and it is expected that a significant part of sprite optical output comes from regions with EEk). Additionally, the values of electric fields inside of the streamer channel are always well below Ek and since the excitation coefficients for optical emissions are very sensitive to the driving electric field magnitude most of the optical luminosity of streamers in this case arises from streamer tips, indicating that observed streamer filaments in many cases may be produced by time averaging of optical luminosity coming from localized regions around streamer tips as streamers move through an instrument's field of view. We will discuss pressure dependent differences of optical emissions at different sprite altitudes, and important similarities between observed sprite streamers and recent time resolved (van Veldhuizen et al., IEEE Trans. Plasma Sci., 30, 162, 2002; Yi and Williams, J. Phys. D. Appl. Phys., 35, 205, 2002].

  12. Optical synchrotron emission in the southern lobe of 3C33

    Energy Technology Data Exchange (ETDEWEB)

    Meisenheimer, K; Roeser, H -J

    1986-02-06

    Charge coupled device polarimetry at a wavelength of 660 nm has detected a highly-polarized optical source, which is coincident with the radio hotspot at the leading edge of the southern lobe of 3C33. The optical polarization data perfectly match the high-frequency Very Large Array observations, thus providing the first direct evidence for optical synchrotron radiation from a classic double radio source. The extended structure of the emission region requires a huge particle accelerator boosting electrons to highly relativistic energies (up to 100 GeV) over a region several kiloparsecs in extent.

  13. Trends in tungsten coil atomic spectrometry

    Science.gov (United States)

    Donati, George L.

    Renewed interest in electrothermal atomic spectrometric methods based on tungsten coil atomizers is a consequence of a world wide increasing demand for fast, inexpensive, sensitive, and portable analytical methods for trace analysis. In this work, tungsten coil atomic absorption spectrometry (WCAAS) and tungsten coil atomic emission spectrometry (WCAES) are used to determine several different metals and even a non-metal at low levels in different samples. Improvements in instrumentation and new strategies to reduce matrix effects and background signals are presented. Investigation of the main factors affecting both WCAAS and WCAES analytical signals points to the importance of a reducing, high temperature gas phase in the processes leading to atomic cloud generation. Some more refractory elements such as V and Ti were determined for the first time by double tungsten coil atomic emission spectrometry (DWCAES). The higher temperatures provided by two atomizers in DWCAES also allowed the detection of Ag, Cu and Sn emission signals for the first time. Simultaneous determination of several elements by WCAES in relatively complex sample matrices was possible after a simple acid extraction. The results show the potential of this method as an alternative to more traditional, expensive methods for fast, more effective analyses and applications in the field. The development of a new metallic atomization cell is also presented. Lower limits of detection in both WCAAS and WCAES determinations were obtained due to factors such as better control of background signal, smaller, more isothermal system, with atomic cloud concentration at the optical path for a longer period of time. Tungsten coil-based methods are especially well suited to applications requiring low sample volume, low cost, sensitivity and portability. Both WCAAS and WCAES have great commercial potential in fields as diverse as archeology and industrial quality control. They are simple, inexpensive, effective

  14. Cold excitation and determination of hydrogen sulfide by dielectric barrier discharge molecular emission spectrometry.

    Science.gov (United States)

    Wu, Zhongchen; Jiang, Jie; Li, Na

    2015-11-01

    A low-temperature microplasma generated in a dielectric barrier discharge (DBD) was used as a radiation source for the excitation of hydrogen sulfide and its determination by molecular emission spectrometry (MES). The excitation/emission chamber was enclosed to eliminate spectral interference from ambient air. The spectral emission lines of hydrogen sulfide were clearly discriminated from the background spectrum, and the emission line at 365.06 nm was selected for parameter optimization and quantitative analysis. The S(2-) ions in aqueous samples were reacted with acid to generate hydrogen sulfide and then determined. The experimental parameters affecting the determination of hydrogen sulfide and S(2-) were optimized. The limits of detection were 1.4 mg m(-3) for H2S and 11.2 mg L(-1) for S(2-). The repeatability of the method was satisfactory, as the RSD values were 2.3% for H2S and 1.8% for S(2-). The enclosed DBD-MES system was demonstrated to be a useful tool for the determination of hydrogen sulfide in gas samples and S(2-) in aqueous samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. An evaluation of microwave-assisted fusion and microwave-assisted acid digestion methods for determining elemental impurities in carbon nanostructures using inductively coupled plasma optical emission spectrometry

    KAUST Repository

    Patole, Shashikant P.

    2015-10-21

    It is common for as-prepared carbon nanotube (CNT) and graphene samples to contain remnants of the transition metals used to catalyze their growth; contamination may also leave other trace elemental impurities in the samples. Although a full quantification of impurities in as-prepared samples of carbon nanostructures is difficult, particularly when trace elements are intercalated or encapsulated within a protective layer of graphitic carbon, reliable information is essential for reasons such as quantifying the adulteration of physico-chemical properties of the materials and for evaluating environmental issues. Here, we introduce a microwave-based fusion method to degrade single- and double-walled CNTs and graphene nanoplatelets into a fusion flux thereby thoroughly leaching all metallic impurities. Subsequent dissolution of the fusion product in diluted hydrochloric and nitric acid allowed us to identify their trace elemental impurities using inductively coupled plasma optical emission spectrometry. Comparisons of the results from the proposed microwave-assisted fusion method against those of a more classical microwave-assisted acid digestion approach suggest complementarity between the two that ultimately could lead to a more reliable and less costly determination of trace elemental impurities in carbon nanostructured materials. Graphical abstract A method for the complete digestion of carbon nanostructures has been demonstrated. Photographs (on the left side) show zirconium crucibles containing SWCNTs with flux of Na2CO3 and K2CO3, before and after microwave fusion; (on the right side) the appearance of the final solutions containing dissolved samples, from microwave-assisted fusion and microwave-assisted acid digestion. These solutions were used for determining the trace elemental impurities by ICP‒OES.

  16. Comparison of the samples injection systems with ultrasonic nebulizer and with pneumatic nebulizer for the metal determination in water by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Marin, Sergio R; Pismante, Paola A

    2005-01-01

    The natural waters, depending on their use, must fulfill the exigencies and requirements that fix national and international norms. These establish conditions with respect to the concentration levels that must be some metals. In this work the development of inductively coupled plasma emission optical spectrometry with ultrasonic injection system is presented. The determination of aluminum, arsenic, barium, cadmium, zinc, cobalt, chromium, copper, iron, manganese, molybdenum, nickel, lead, strontium and vanadium, at levels of ultra-trace in water samples is studied by this technique. The wavelengths that represented better sensitivity and minors spectral interferences, were selected from the Literature specialized in the analysis of this type of material. Also the conditions of work for the ultrasonic nebulization: temperature, pressure, flow speed of argon, and flow speed of sample was determined. The greater sensitivity of the injection system by ultrasonic nebulization forehead to the injection system by pneumatic nebulization, is verified when comparing the spectral intensity of the selected wavelengths. Also the limits of detection and quantification was obtained by both systems. The validity of the results obtained in this method is verified applying the test of Fisher, who determines the degree of homogeneity of the variances, and the test of Student, to determine the trazability obtained with these values. For these studies, the certified material of reference TM-24.2 of National Water Research Institute Environment Canada (NWRI), was used. The positive answer to the criteria of evaluation E and Z-Score, obtained by this technique, allows to verify that it fulfills the exigencies to be used in the determination of metals at the required levels (au)

  17. Aggregation induced enhancement of linear and nonlinear optical emission from a hexaphenylene derivative

    NARCIS (Netherlands)

    Duan, Y.; Ju, C.G.; Yang, G.; Fron, E.; Coutino-Gonzalez, E.; Semin, S.V.; Fan, C.C.; Balok, R.S.; Cremers, J.; Tinnemans, P.T.; Feng, Y.Q.; Li, Y.L.; Hofkens, J.; Rowan, A.E.; Rasing, T.H.M.; Xu, J.L.

    2016-01-01

    The discovery of the phenomenon known as aggregation-induced emission (AIE) has opened the door to a variety of brilliant organic solid-state light-emitting materials. While AIE is well established in linear optics, the development of AIE luminogens (AIEgens) with highly efficient nonlinear optical

  18. DETECTION OF REST-FRAME OPTICAL LINES FROM X-SHOOTER SPECTROSCOPY OF WEAK EMISSION-LINE QUASARS

    International Nuclear Information System (INIS)

    Plotkin, Richard M.; Gallo, Elena; Shemmer, Ohad; Trakhtenbrot, Benny; Anderson, Scott F.; Brandt, W. N.; Luo, Bin; Schneider, Donald P.; Fan, Xiaohui; Lira, Paulina; Richards, Gordon T.; Strauss, Michael A.; Wu, Jianfeng

    2015-01-01

    Over the past 15 yr, examples of exotic radio-quiet quasars with intrinsically weak or absent broad emission line regions (BELRs) have emerged from large-scale spectroscopic sky surveys. Here, we present spectroscopy of seven such weak emission line quasars (WLQs) at moderate redshifts (z = 1.4–1.7) using the X-shooter spectrograph, which provides simultaneous optical and near-infrared spectroscopy covering the rest-frame ultraviolet (UV) through optical. These new observations effectively double the number of WLQs with spectroscopy in the optical rest-frame, and they allow us to compare the strengths of (weak) high-ionization emission lines (e.g., C iv) to low-ionization lines (e.g., Mg ii, Hβ, Hα) in individual objects. We detect broad Hβ and Hα emission in all objects, and these lines are generally toward the weaker end of the distribution expected for typical quasars (e.g., Hβ has rest-frame equivalent widths ranging from 15–40 Å). However, these low-ionization lines are not exceptionally weak, as is the case for high-ionization lines in WLQs. The X-shooter spectra also display relatively strong optical Fe ii emission, Hβ FWHM ≲ 4000 km s −1 , and significant C iv blueshifts (≈1000–5500 km s −1 ) relative to the systemic redshift; two spectra also show elevated UV Fe ii emission, and an outflowing component to their (weak) Mg ii emission lines. These properties suggest that WLQs are exotic versions of “wind-dominated” quasars. Their BELRs either have unusual high-ionization components, or their BELRs are in an atypical photoionization state because of an unusually soft continuum

  19. Discovery of a cosmological, relativistic outburst via its rapidly fading optical emission

    International Nuclear Information System (INIS)

    Cenko, S. Bradley; Nugent, Peter E.; Miller, Adam A.; Bloom, Joshua S.; Filippenko, Alexei V.; Kulkarni, S. R.; Horesh, Assaf; Carpenter, John; Perley, Daniel A.; Groot, Paul J.; Hallinan, G.; Corsi, Alessandra; Fox, Derek B.; Frail, Dale A.; Gruber, D.; Rau, Arne; Gal-Yam, Avishay; Ofek, Eran O.; MacLeod, Chelsea L.; Kasliwal, Mansi M.

    2013-01-01

    We report the discovery by the Palomar Transient Factory (PTF) of the transient source PTF11agg, which is distinguished by three primary characteristics: (1) bright (R peak = 18.3 mag), rapidly fading (ΔR = 4 mag in Δt = 2 days) optical transient emission; (2) a faint (R = 26.2 ± 0.2 mag), blue (g' – R = 0.17 ± 0.29 mag) quiescent optical counterpart; and (3) an associated year-long, scintillating radio transient. We argue that these observed properties are inconsistent with any known class of Galactic transients (flare stars, X-ray binaries, dwarf novae), and instead suggest a cosmological origin. The detection of incoherent radio emission at such distances implies a large emitting region, from which we infer the presence of relativistic ejecta. The observed properties are all consistent with the population of long-duration gamma-ray bursts (GRBs), marking the first time such an outburst has been discovered in the distant universe independent of a high-energy trigger. We searched for possible high-energy counterparts to PTF11agg, but found no evidence for associated prompt emission. We therefore consider three possible scenarios to account for a GRB-like afterglow without a high-energy counterpart: an 'untriggered' GRB (lack of satellite coverage), an 'orphan' afterglow (viewing-angle effects), and a 'dirty fireball' (suppressed high-energy emission). The observed optical and radio light curves appear inconsistent with even the most basic predictions for off-axis afterglow models. The simplest explanation, then, is that PTF11agg is a normal, on-axis long-duration GRB for which the associated high-energy emission was simply missed. However, we have calculated the likelihood of such a serendipitous discovery by PTF and find that it is quite small (≈2.6%). While not definitive, we nonetheless speculate that PTF11agg may represent a new, more common (>4 times the on-axis GRB rate at 90% confidence) class of relativistic

  20. Discovery of a cosmological, relativistic outburst via its rapidly fading optical emission

    Energy Technology Data Exchange (ETDEWEB)

    Cenko, S. Bradley; Nugent, Peter E.; Miller, Adam A.; Bloom, Joshua S.; Filippenko, Alexei V. [Department of Astronomy, University of California, Berkeley, CA 94720-3411 (United States); Kulkarni, S. R.; Horesh, Assaf; Carpenter, John; Perley, Daniel A.; Groot, Paul J.; Hallinan, G. [Cahill Center for Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Corsi, Alessandra [LIGO Laboratory, California Institute of Technology, MS 100-36, Pasadena, CA 91125 (United States); Fox, Derek B. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Frail, Dale A. [National Radio Astronomy Observatory, P.O. Box O, Socorro, NM 87801 (United States); Gruber, D.; Rau, Arne [Max Planck Institute for Extraterrestrial Physics, Giessenbachstrasse, Postfach 1312, D-85748 Garching (Germany); Gal-Yam, Avishay; Ofek, Eran O. [Benoziyo Center for Astrophysics, Weizmann Institute of Science, 76100 Rehovot (Israel); MacLeod, Chelsea L. [Physics Department, United States Naval Academy, 572c Holloway Road, Annapolis, MD 21402 (United States); Kasliwal, Mansi M., E-mail: cenko@astro.berkeley.edu [Observatories of the Carnegie Institution for Science, 813 Santa Barbara St., Pasadena, CA 91101 (United States); and others

    2013-06-01

    We report the discovery by the Palomar Transient Factory (PTF) of the transient source PTF11agg, which is distinguished by three primary characteristics: (1) bright (R {sub peak} = 18.3 mag), rapidly fading (ΔR = 4 mag in Δt = 2 days) optical transient emission; (2) a faint (R = 26.2 ± 0.2 mag), blue (g' – R = 0.17 ± 0.29 mag) quiescent optical counterpart; and (3) an associated year-long, scintillating radio transient. We argue that these observed properties are inconsistent with any known class of Galactic transients (flare stars, X-ray binaries, dwarf novae), and instead suggest a cosmological origin. The detection of incoherent radio emission at such distances implies a large emitting region, from which we infer the presence of relativistic ejecta. The observed properties are all consistent with the population of long-duration gamma-ray bursts (GRBs), marking the first time such an outburst has been discovered in the distant universe independent of a high-energy trigger. We searched for possible high-energy counterparts to PTF11agg, but found no evidence for associated prompt emission. We therefore consider three possible scenarios to account for a GRB-like afterglow without a high-energy counterpart: an 'untriggered' GRB (lack of satellite coverage), an 'orphan' afterglow (viewing-angle effects), and a 'dirty fireball' (suppressed high-energy emission). The observed optical and radio light curves appear inconsistent with even the most basic predictions for off-axis afterglow models. The simplest explanation, then, is that PTF11agg is a normal, on-axis long-duration GRB for which the associated high-energy emission was simply missed. However, we have calculated the likelihood of such a serendipitous discovery by PTF and find that it is quite small (≈2.6%). While not definitive, we nonetheless speculate that PTF11agg may represent a new, more common (>4 times the on-axis GRB rate at 90% confidence) class of relativistic

  1. Total sulfur determination in gasoline, kerosene and diesel fuel using inductively coupled plasma optical emission spectrometry after direct sample introduction as detergent emulsions

    International Nuclear Information System (INIS)

    Santelli, Ricardo Erthal; Padua Oliveira, Eliane; Batista de Carvalho, Maria de Fatima; Almeida Bezerra, Marcos; Soares Freire, Aline

    2008-01-01

    Herein, we present the development of a procedure for the determination of total sulfur in petroleum-derived products (gasoline, kerosene and diesel fuel) employing inductively coupled plasma optical emission spectrometry (ICP OES). For this procedure, samples were prepared as emulsions that were made using concentrated nitric acid, Triton X-100, sample, and ultra pure water in proportions of 5/10/7/78% (v/v), respectively. Sample volumes were weighed because of the density differences, and oxygen was added to the sheat gas entrance of the ICP OES in order to decrease carbon deposition in the torch and to minimize background effects. A Doehlert design was applied as an experimental matrix to investigate the flow ratios of argon (sheat and plasma gas) and oxygen in relation to the signal-to-background ratio. A comparative study among the slopes of the analytical curves built in aqueous media, surfactant/HNO 3 , and by spike addition for several sample emulsions indicates that a unique solution of surfactant in acidic media can be employed to perform the external calibration for analysis of the emulsions. The developed procedure allows for the determination of the total sulfur content in petroleum derivatives with a limit of detection (LOD) and limit of quantification (LOQ) of 0.72 and 2.4 μg g -1 , respectively. Precision values, expressed as the relative standard deviations (% RSD, n = 10) for 12 and 400 μg g -1 , were 2.2% and 1.3%, respectively. The proposed procedure was applied toward the determination of total sulfur in samples of gasoline, kerosene, and diesel fuel commercialized in the city of Niteroi/RJ, Brazil. The accuracy of the proposed method was evaluated by the determination of the total sulfur in three different standard reference materials (SRM): NIST 2723a (sulfur in diesel fuel oil), NIST 1616b (sulfur in kerosene), and NIST 2298 (sulfur in gasoline). The data indicate that the methodology can be successfully applied to these types of samples

  2. Optical emission from a high-refractive-index waveguide excited by a traveling electron beam

    International Nuclear Information System (INIS)

    Kuwamura, Yuji; Yamada, Minoru; Okamoto, Ryuichi; Kanai, Takeshi; Fares, Hesham

    2008-01-01

    An optical emission scheme was demonstrated, in which a high-refractive-index waveguide is excited by a traveling electron beam in a vacuum environment. The waveguide was made of Si-SiO 2 layers. The velocity of light propagating in the waveguide was slowed down to 1/3 of that in free space due to the high refractive index of Si. The light penetrated partly into the vacuum in the form of a surface wave. The electron beam was emitted from an electron gun and propagated along the surface of the waveguide. When the velocity of the electron coincided with that of the light, optical emission was observed. This emission is a type of Cherenkov radiation and is not conventional cathode luminescence from the waveguide materials because Si and SiO 2 are transparent to light at the emitted wavelength. This type of emission was observed in an optical wavelength range from 1.2 to 1.6 μm with an electron acceleration voltage of 32-42 kV. The characteristics of the emitted light, such as the polarization direction and the relation between the acceleration voltage of the electron beam and the optical wavelength, coincided well with the theoretical results. The coherent length of an electron wave in the vacuum was confirmed to be equal to the electron spacing, as found by measuring the spectral profile of the emitted light

  3. Thermoluminescence emission spectra and optical bleaching of oligoclase

    International Nuclear Information System (INIS)

    Bos, A.J.J.; Piters, T.M.; Ypma, P.J.

    1994-01-01

    Thermoluminescence (TL) spectra of oligoclase samples have been recorded in the temperature range from 300 to 700 K and the wavelength range from 300 to 850 nm. Like other feldspars, oligoclase produces blue (peaking at 460 nm) and red (peaking at 765 nm) emission bands. The maximum of the red emission occurs 20 K lower than that of the blue band. Optical bleaching was performed at wavelengths varying from 360 to 800 nm. Bleaching of artificially irradiated oligoclase causes a decrease of the TL signal. The bleaching efficiency increases with decreasing wavelength. Bleaching does not only influence the height of the glow curve but also the shape. An interesting observation is that the ratio of the blue and red band intensities is not affected by a bleaching procedure. No evidence has been found that bleaching influences the shape of the emission spectra. The correlation between the blue and red bands is discussed. (Author)

  4. Spectroscopy of optically selected BL Lac objects and their γ-ray emission

    Energy Technology Data Exchange (ETDEWEB)

    Sandrinelli, A.; Treves, A.; Farina, E. P.; Landoni, M. [Università degli Studi dell' Insubria, Via Valleggio 11, I-22100 Como (Italy); Falomo, R. [INAF-Osservatorio Astronomico di Padova, Vicolo dell Osservatorio 5, I-35122 Padova (Italy); Foschini, L.; Sbarufatti, B., E-mail: angela.sandrinelli@brera.inaf.it [INAF-Osservatorio Astronomico di Brera, Via Emilio Bianchi 46, I-23807 Merate (Italy)

    2013-12-01

    We present Very Large Telescope optical spectroscopy of nine BL Lac objects of unknown redshift belonging to the list of optically selected radio-loud BL Lac candidates. We explore their spectroscopic properties and possible link with gamma-ray emission. From the new observations we determine the redshifts of four objects from faint emission lines or from absorption features of their host galaxies. In three cases we find narrow intervening absorptions from which a lower limit to the redshift is inferred. For the remaining two featureless sources, lower limits to the redshift are deduced from the absence of spectral lines. A search for γ counterpart emission shows that six out of the nine candidates are Fermi γ-ray emitters and we find two new detections. Our analysis suggests that most of the BL Lac objects still lacking redshift information are most likely located at high redshifts.

  5. Optical and x-ray imaging of electron beams using synchrotron emission

    International Nuclear Information System (INIS)

    Wilke, M.

    1995-01-01

    In the case of very low emittance electron and positron storage ring beams, it is impossible to make intrusive measurements of beam properties without increasing the emittance and possibly disrupting the beam. In cases where electron or positron beams have high average power densities (such as free electron laser linacs), intrusive probes such as wires and optical transition radiation screens or Cherenkov emitting screens can be easily damaged or destroyed. The optical and x-ray emissions from the bends in the storage rings and often from linac bending magnets can be used to image the beam profile to obtain emittance information about the beam. The techniques, advantages and limitations of using both optical and x-ray synchrotron emission to measure beam properties are discussed and the possibility of single bunch imaging is considered. The properties of suitable imagers and converters such as phosphors are described. Examples of previous, existing and planned applications are given where available, including a pinhole imaging system currently being designed for the Advanced Photon Source at Argonne National Laboratory

  6. Optical and x-ray imaging of electron beams using synchrotron emission

    International Nuclear Information System (INIS)

    Wilke, M.D.

    1994-01-01

    In the case of very low eniittance electron and positron storage ring beams, it is impossible to make intrusive measurements of beam properties without increasing the emittance and possibly disrupting the beam. In cases where electron or positron beams have high average power densities (such as free electron laser linacs), intrusive probes such as wires and optical transition radiation screens or Cherenkov emitting screens can be easily damaged or destroyed. The optical and x-ray emissions from the bends in the storage rings and often from linac bending magnets can be used to image the beam profile to obtain emittance information about the beam. The techniques, advantages and limitations of using both optical and x-ray synchrotron emission to measure beam properties are discussed and the possibility of single bunch imaging is considered. The properties of suitable imagers and converters such as phosphors are described. Examples of previous, existing and planned applications are given where available, including a pinhole imaging system currently being designed for the Advanced Photon Source at Argonne National Laboratory

  7. Modeling of N2 and O optical emissions for ionosphere HF powerful heating experiments

    Science.gov (United States)

    Sergienko, T.; Gustavsson, B.

    Analyses of experiments of F region ionosphere modification by HF powerful radio waves show that optical observations are very useful tools for diagnosing of the interaction of the probing radio wave with the ionospheric plasma Hitherto the emissions usually measured in the heating experiment have been the 630 0 nm and the 557 7 nm lines of atomic oxygen Other emissions for instance O 844 8 nm and N2 427 8 nm have been measured episodically in only a few experiments although the very rich optical spectrum of molecular nitrogen potentially involves important information about ionospheric plasma in the heated region This study addresses the modeling of optical emissions from the O and the N2 triplet states first positive second positive Vegard-Kaplan infrared afterglow and Wu-Benesch band systems excited under a condition of the ionosphere heating experiment The auroral triplet state population distribution model was modified for the ionosphere heating conditions by using the different electron distribution functions suggested by Mishin et al 2000 2003 and Gustavsson at al 2004 2005 Modeling results are discussed from the point of view of efficiency of measurements of the N2 emissions in future experiments

  8. Optical emission line spectra of Seyfert galaxies and radio galaxies

    International Nuclear Information System (INIS)

    Osterbrock, D.E.

    1978-01-01

    Many radio galaxies have strong emission lines in their optical spectra, similar to the emission lines in the spectra of Seyfert galaxies. The range of ionization extends from [O I] and [N I] through [Ne V] and [Fe VII] to [Fe X]. The emission-line spectra of radio galaxies divide into two types, narrow-line radio galaxies whose spectra are indistinguishable from Seyfert 2 galaxies, and broad-line radio galaxies whose spectra are similar to Seyfert 1 galaxies. However on the average the broad-line radio galaxies have steeper Balmer decrements, stronger [O III] and weaker Fe II emission than the Seyfert 1 galaxies, though at least one Seyfert 1 galaxy not known to be a radio source has a spectrum very similar to typical broad-line radio galaxies. Intermediate-type Seyfert galaxies exist that show various mixtures of the Seyfert 1 and Seyfert 2 properties, and the narrow-line or Seyfert 2 property seems to be strongly correlated with radio emission. (Auth.)

  9. Multimode laser emission from dye-doped hollow polymer optical fibre

    Indian Academy of Sciences (India)

    2014-02-09

    Feb 9, 2014 ... Fibre lasers; optical microcavities; whispering gallery modes. ... A blueshift in the mode structure was observed with decrease in fibre diameter leading to wide range tunability of the laser emission. ... International School of Photonics, Cochin University of Science & Technology, Cochin 682 022, India ...

  10. Atomic Absorption, Atomic Fluorescence, and Flame Emission Spectrometry.

    Science.gov (United States)

    Horlick, Gary

    1984-01-01

    This review is presented in six sections. Sections focus on literature related to: (1) developments in instrumentation, measurement techniques, and procedures; (2) performance studies of flames and electrothermal atomizers; (3) applications of atomic absorption spectrometry; (4) analytical comparisons; (5) atomic fluorescence spectrometry; and (6)…

  11. Experimental evidence of state-selective charge transfer in inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Chan, George C.-Y.; Hieftje, Gary M.

    2004-01-01

    State-selective charge-transfer behavior was observed for Fe, Cr, Mn and Cu in inductively coupled plasma (ICP)-atomic emission spectrometry. Charge transfer from Ar + to Fe, Cr and Mn is state-selective because of inefficient collisional mixing of the quasiresonant charge-transfer energy levels with nearby levels. This low efficiency is the consequence of differences in electronic configuration of the core electrons. The reason for state-selective charge-transfer behavior to Cu is not clear, although a tentative explanation based on efficiency of intramultiplet and intermultiplet mixing for this special case is offered

  12. Functional imaging in bulk tissue specimens using optical emission tomography: fluorescence preservation during optical clearing

    International Nuclear Information System (INIS)

    Sakhalkar, H S; Dewhirst, M; Oliver, T; Cao, Y; Oldham, M

    2007-01-01

    Optical emission computed tomography (optical-ECT) is a technique for imaging the three-dimensional (3D) distribution of fluorescent probes in biological tissue specimens with high contrast and spatial resolution. In optical-ECT, functional information can be imaged by (i) systemic application of functional labels (e.g. fluorophore labelled proteins) and/or (ii) endogenous expression of fluorescent reporter proteins (e.g. red fluorescent protein (RFP), green fluorescent protein (GFP)) in vivo. An essential prerequisite for optical-ECT is optical clearing, a procedure where tissue specimens are made transparent to light by sequential perfusion with fixing, dehydrating and clearing agents. In this study, we investigate clearing protocols involving a selection of common fixing (4% buffered paraformaldehyde (PFA), methanol and ethanol), dehydrating (methanol and ethanol) and clearing agents (methyl salicylate and benzyl-alcohol-benzyl-benzoate (BABB)) in order to determine a 'fluorescence friendly' clearing procedure. Cell culture experiments were employed to optimize the sequence of chemical treatments that best preserve fluorescence. Texas red (TxRed), fluorescein isothiocyanate (FITC), RFP and GFP were tested as fluorophores and fluorescent reporter proteins of interest. Fluorescent and control cells were imaged on a microscope using a DSred2 and FITC filter set. The most promising clearing protocols of cell culture experiments were applied to whole xenograft tumour specimens, to test their effectiveness in large unsectioned samples. Fluorescence of TxRed/FITC fluorophores was not found to be significantly affected by any of the test clearing protocols. RFP and GFP fluorescence, however, was found to be significantly greater when cell fixation was in ethanol. Fixation in either PFA or methanol resulted in diminished fluorescence. After ethanol fixation, the RFP and GFP fluorescence proved remarkably robust to subsequent exposure to either methyl salicylate or BABB

  13. Functional imaging in bulk tissue specimens using optical emission tomography: fluorescence preservation during optical clearing

    Energy Technology Data Exchange (ETDEWEB)

    Sakhalkar, H S [Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710 (United States); Dewhirst, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710 (United States); Oliver, T [Department of Cell Biology, Duke University Medical Center, Durham, NC 27710 (United States); Cao, Y [Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710 (United States); Oldham, M [Department of Radiation Oncology Physics, and Biomedical Engineering, Duke University Medical Center, Durham, NC 27710 (United States)

    2007-04-21

    Optical emission computed tomography (optical-ECT) is a technique for imaging the three-dimensional (3D) distribution of fluorescent probes in biological tissue specimens with high contrast and spatial resolution. In optical-ECT, functional information can be imaged by (i) systemic application of functional labels (e.g. fluorophore labelled proteins) and/or (ii) endogenous expression of fluorescent reporter proteins (e.g. red fluorescent protein (RFP), green fluorescent protein (GFP)) in vivo. An essential prerequisite for optical-ECT is optical clearing, a procedure where tissue specimens are made transparent to light by sequential perfusion with fixing, dehydrating and clearing agents. In this study, we investigate clearing protocols involving a selection of common fixing (4% buffered paraformaldehyde (PFA), methanol and ethanol), dehydrating (methanol and ethanol) and clearing agents (methyl salicylate and benzyl-alcohol-benzyl-benzoate (BABB)) in order to determine a 'fluorescence friendly' clearing procedure. Cell culture experiments were employed to optimize the sequence of chemical treatments that best preserve fluorescence. Texas red (TxRed), fluorescein isothiocyanate (FITC), RFP and GFP were tested as fluorophores and fluorescent reporter proteins of interest. Fluorescent and control cells were imaged on a microscope using a DSred2 and FITC filter set. The most promising clearing protocols of cell culture experiments were applied to whole xenograft tumour specimens, to test their effectiveness in large unsectioned samples. Fluorescence of TxRed/FITC fluorophores was not found to be significantly affected by any of the test clearing protocols. RFP and GFP fluorescence, however, was found to be significantly greater when cell fixation was in ethanol. Fixation in either PFA or methanol resulted in diminished fluorescence. After ethanol fixation, the RFP and GFP fluorescence proved remarkably robust to subsequent exposure to either methyl salicylate

  14. The impact of molecular emission in compositional depth profiling using Glow Discharge-Optical Emission Spectroscopy

    International Nuclear Information System (INIS)

    Bengtson, Arne

    2008-01-01

    The scope of this paper is to investigate and discuss how molecular emission can affect elemental analysis in glow discharge optical emission (GD-OES), particularly in compositional depth profiling (CDP) applications. Older work on molecular emission in glow discharges is briefly reviewed, and the nature of molecular emission spectra described. Work on the influence of hydrogen in the plasma, in particular elevated background due to a continuum spectrum, is discussed. More recent work from sputtering of polymers and other materials with a large content of light elements in a Grimm type source is reviewed, where substantial emission has been observed from several light diatomic molecules (CO, CH, OH, NH, C 2 ). It is discussed how the elevated backgrounds from such molecular emission can lead to significant analytical errors in the form of 'false' depth profile signals of several atomic analytical lines. Results from a recent investigation of molecular emission spectra from mixed gases in a Grimm type glow discharge are presented. An important observation is that dissociation and subsequent recombination processes occur, leading to formation of molecular species not present in the original plasma gas. Experimental work on depth profiling of a polymer coating and a thin silicate film, using a spectrometer equipped with channels for molecular emission lines, is presented. The results confirm that molecular emission gives rise to apparent depth profiles of elements not present in the sample. The possibilities to make adequate corrections for such molecular emission in CDP of organic coatings and very thin films are discussed

  15. The impact of molecular emission in compositional depth profiling using Glow Discharge-Optical Emission Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bengtson, Arne [Corrosion and Metals Research Institute, Dr. Kristinas vaeg 48, Stockholm (Sweden)], E-mail: arne.bengtson@kimab.com

    2008-09-15

    The scope of this paper is to investigate and discuss how molecular emission can affect elemental analysis in glow discharge optical emission (GD-OES), particularly in compositional depth profiling (CDP) applications. Older work on molecular emission in glow discharges is briefly reviewed, and the nature of molecular emission spectra described. Work on the influence of hydrogen in the plasma, in particular elevated background due to a continuum spectrum, is discussed. More recent work from sputtering of polymers and other materials with a large content of light elements in a Grimm type source is reviewed, where substantial emission has been observed from several light diatomic molecules (CO, CH, OH, NH, C{sub 2}). It is discussed how the elevated backgrounds from such molecular emission can lead to significant analytical errors in the form of 'false' depth profile signals of several atomic analytical lines. Results from a recent investigation of molecular emission spectra from mixed gases in a Grimm type glow discharge are presented. An important observation is that dissociation and subsequent recombination processes occur, leading to formation of molecular species not present in the original plasma gas. Experimental work on depth profiling of a polymer coating and a thin silicate film, using a spectrometer equipped with channels for molecular emission lines, is presented. The results confirm that molecular emission gives rise to apparent depth profiles of elements not present in the sample. The possibilities to make adequate corrections for such molecular emission in CDP of organic coatings and very thin films are discussed.

  16. Correlation of optical emission and turbulent length scale in a coaxial jet diffusion flame

    OpenAIRE

    松山, 新吾; Matsuyama, Shingo

    2014-01-01

    This article investigates the correlation between optical emission and turbulent length scale in a coaxial jet diffusion flame. To simulate the H2O emission from an H2/O2 diffusion flame, radiative transfer is calculated on flame data obtained by numerical simulation. H2O emission characteristics are examined for a one-dimensional opposed-flow diffusion flame. The results indicate that H2O emission intensity is linearly dependent on flame thickness. The simulation of H2O emission is then exte...

  17. Prediction of TARANIS Observations of TGF's and Optical Emissions from Red Sprites

    Science.gov (United States)

    Nelson, M. A.

    2006-12-01

    TARANIS (Tool for the Analysis of Radiation from Lightning and Sprites) is a French (CNES, Centre National D'Etudes Spatiales) micro-satellite that is scheduled for launch in 2009. This will be the first satellite that will measure coincident gamma-rays and optical emissions from atmospheric discharges. These measurements will provide important clues concerning the physics of discharges that produce gamma-rays and will provide more definitive evidence of the role of conventional breakdown versus runaway breakdown than is currently available. While a variety of discharges may be associated with Transient Gamma Ray Flashes (TGF's), this study will focus on emissions expected from red sprites. Future studies will focus on other types of discharges (for example, gigantic jets or blue jets) to see whether they should produce detectable signal levels at both gamma-ray and optical frequencies. The source of terrestrial TGF's is a matter of debate at this time. Many experts in the field have interpreted the data associated with the RHESSI (Reuven Ramaty High Energy Solar Spectroscopic Imager) satellite to be indicative that the discharges associated with terrestrial gamma-rays are not associated with sprites. However, RHESSI was not designed for the purpose of collecting gamma-ray measurements from terrestrial discharges; does not possess a coincident optical measurement capability; and must average data over many events to predict a spectrum. We will present a statistical analysis of the relative efficiencies of the RHESSI and TARANIS satellite designs for the detection of TGF's associated with sprites. We will show results from a fully 2-D electromagnetic model (UNIMAX, the Unified Maxwell code) and an optical model (POEM, the Physics Based Optical Emission Model) to demonstrate the level of agreement between the simulations and the gamma-ray spectrum measurements and optical measurements (camera, photometer, and spectral measurements) for several different classes of

  18. Large hoisting machinery local damage acoustic emission monitoring of optical information acquisition research

    Directory of Open Access Journals (Sweden)

    Wan Shuai

    2016-01-01

    Full Text Available AE technology, an advanced fault diagnosis technique,is impacted by environmental noise during monitoring equipment. The occurrence of interfere noise,the fashion of interfere and the effect to the system in the AE automatic online monitoring system is analyzed. At present, most of the acoustic emission signal transmission by cable, this way of transmission has a limited transmission distance, shortcomings and so on signal easily disturbed. Is proposed in this paper based on the optical fiber transmission technology, designed and developed a information collection system based on optical fiber acoustic emission monitoring.This way has the advantages of long distance transmission, strong anti-jamming capability.

  19. Preliminary studies of laser-induced breakdown spectrometry for the determination of Ba, Cd, Cr and Pb in toys

    International Nuclear Information System (INIS)

    Godoi, Quienly; Santos, Dario; Nunes, Lidiane C.; Leme, Flavio O.; Rufini, Iolanda A.; Agnelli, Jose A.M.; Trevizan, Lilian C.; Krug, Francisco J.

    2009-01-01

    The performance of laser-induced breakdown spectrometry (LIBS) for the determination of Ba, Cd, Cr and Pb in toys has been evaluated by using a Nd:YAG laser operating at 1064 nm and an Echelle spectrometer with intensified charge-coupled device detector. Samples were purchased in different cities of Sao Paulo State market and analyzed directly without sample preparation. Laser-induced breakdown spectrometry experimental conditions (number of pulses, delay time, integration time gate and pulse energy) were optimized by using a Doehlert design. Laser-induced breakdown spectrometry signals correlated reasonably well with inductively coupled plasma optical emission spectrometry (ICP OES) concentrations after microwave-assisted acid digestion of selected samples. Thermal analysis was used for polymer identification and scanning electron microscopy to visualize differences in crater geometry of different polymers employed for toy fabrication. Results indicate that laser-induced breakdown spectrometry can be proposed as a rapid screening method for investigation of potentially toxic elements in toys. The unique application of laser-induced breakdown spectrometry for identification of contaminants in successive layers of ink and polymer is also demonstrated.

  20. Artificial optical emissions at HAARP for pump frequencies near the third and second electron gyro-harmonic

    Directory of Open Access Journals (Sweden)

    M. J. Kosch

    2005-07-01

    Full Text Available High-power high-frequency radio waves beamed into the ionosphere cause plasma turbulence, which can accelerate electrons. These electrons collide with the F-layer neutral oxygen causing artificial optical emissions identical to natural aurora. Pumping at electron gyro-harmonic frequencies has special significance as many phenomena change their character. In particular, artificial optical emissions become strongly reduced for the third and higher gyro-harmonics. The High frequency Active Auroral Research Program (HAARP facility is unique in that it can select a frequency near the second gyro-harmonic. On 25 February 2004, HAARP was operated near the third and passed through the second gyro-harmonic for the first time in a weakening ionosphere. Two novel observations are: firstly, a strong enhancement of the artificial optical emission intensity near the second gyro-harmonic, which is opposite to higher gyro-harmonics; secondly, the optical enhancement maximum occurs for frequencies just above the second gyro-harmonic. We provide the first experimental evidence for these effects, which have been predicted theoretically. In addition, irregular optical structures were created when the pump frequency was above the ionospheric critical frequency.

    Keywords. Active experiments – Auroral ionosphere – Wave-particle interactions

  1. Artificial optical emissions at HAARP for pump frequencies near the third and second electron gyro-harmonic

    Directory of Open Access Journals (Sweden)

    M. J. Kosch

    2005-07-01

    Full Text Available High-power high-frequency radio waves beamed into the ionosphere cause plasma turbulence, which can accelerate electrons. These electrons collide with the F-layer neutral oxygen causing artificial optical emissions identical to natural aurora. Pumping at electron gyro-harmonic frequencies has special significance as many phenomena change their character. In particular, artificial optical emissions become strongly reduced for the third and higher gyro-harmonics. The High frequency Active Auroral Research Program (HAARP facility is unique in that it can select a frequency near the second gyro-harmonic. On 25 February 2004, HAARP was operated near the third and passed through the second gyro-harmonic for the first time in a weakening ionosphere. Two novel observations are: firstly, a strong enhancement of the artificial optical emission intensity near the second gyro-harmonic, which is opposite to higher gyro-harmonics; secondly, the optical enhancement maximum occurs for frequencies just above the second gyro-harmonic. We provide the first experimental evidence for these effects, which have been predicted theoretically. In addition, irregular optical structures were created when the pump frequency was above the ionospheric critical frequency.Keywords. Active experiments – Auroral ionosphere – Wave-particle interactions

  2. Optical Emission Spectroscopy of Plasma in Hybrid Pulsed Laser Deposition System

    Czech Academy of Sciences Publication Activity Database

    Novotný, Michal; Jelínek, Miroslav; Bulíř, Jiří; Lančok, Ján; Jastrabík, Lubomír; Zelinger, Zdeněk

    2002-01-01

    Roč. 52, Suppl. D (2002), s. 292-298 ISSN 0011-4626 R&D Projects: GA AV ČR IAA1010110 Keywords : optical emission spectroscopy * pulsed laser deposition * RF discharge Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.311, year: 2002

  3. Investigations on the use of pneumatic cross-flow nebulizers with dual solution loading including the correction of matrix effects in elemental determinations by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Bauer, Mathieu; Broekaert, Jose A.C.

    2007-01-01

    The use of a so-called trihedral and a T-shaped cross-flow pneumatic nebulizer with dual solution loading for inductively coupled plasma optical emission spectrometry has been studied. By these devices analyte clouds from two solutions can be mixed during the aerosol generation step. For both nebulizers the correction of matrix effects using internal standardization and standard addition calibration in an on-line way was investigated and compared to elemental determinations using a conventional cross-flow nebulizer and calibration with synthetic standard solutions without matrix matching. A significant improvement of accuracy, both for calibration with internal standardization and standard addition, was obtained in the case of four synthetic solutions containing each 40 mmol L -1 Na, K, Rb and Ba as matrix elements and 300 μg L -1 Cd, Co, Cr, Cu, Fe, Mn, Ni and Pb as analytes. Calibration by standard addition in the case of dual solution loading has been shown to be very useful in the determination of elements at minor and trace levels in steel and alumina reference materials. The results of analysis for minor concentrations of Cr, Cu and Ni in steel as well as for Ca, Fe, Ga, Li, Mg, Mn, Na, Si and Zn in alumina powder certified reference materials subsequent to sample dissolution were found to be in good agreement with the certificates. Limits of detection were found to be only slightly above those for a conventional cross-flow nebulizer and a precision better than 3% was realized with both novel nebulizers

  4. Sample Preprocessing For Atomic Spectrometry

    International Nuclear Information System (INIS)

    Kim, Sun Tae

    2004-08-01

    This book gives descriptions of atomic spectrometry, which deals with atomic absorption spectrometry such as Maxwell-Boltzmann equation and Beer-Lambert law, atomic absorption spectrometry for solvent extraction, HGAAS, ETASS, and CVAAS and inductively coupled plasma emission spectrometer, such as basic principle, generative principle of plasma and device and equipment, and interferences, and inductively coupled plasma mass spectrometry like device, pros and cons of ICP/MS, sample analysis, reagent, water, acid, flux, materials of experiments, sample and sampling and disassembling of sample and pollution and loss in open system and closed system.

  5. Comparison of a portable micro-X-ray fluorescence spectrometry with inductively coupled plasma atomic emission spectrometry for the ancient ceramics analysis

    International Nuclear Information System (INIS)

    Papadopoulou, D.N.; Zachariadis, G.A.; Anthemidis, A.N.; Tsirliganis, N.C.; Stratis, J.A.

    2004-01-01

    Two multielement instrumental methods of analysis, micro X-ray fluorescence spectrometry (micro-XRF) and inductively coupled plasma atomic emission spectrometry (ICP-AES) were applied for the analysis of 7th and 5th century B.C. ancient ceramic sherds in order to evaluate the above two methods and to assess the potential to use the current compact and portable micro-XRF instrument for the in situ analysis of ancient ceramics. The distinguishing factor of interest is that micro-XRF spectrometry offers the possibility of a nondestructive analysis, an aspect of primary importance in the compositional analysis of cultural objects. Micro-XRF measurements were performed firstly directly on the ceramic sherds with no special pretreatment apart from surface cleaning (micro-XRF on sherds) and secondly on pressed pellet disks which were prepared for each ceramic sherd (micro-XRF on pellet). For the ICP-AES determination of elements, test solutions were prepared by the application of a microwave-assisted decomposition procedure in closed high-pressure PFA vessels. Also, the standard reference material SARM 69 was used for the efficiency calibration of the micro-XRF instrument and was analysed by both methods. In order to verify the calibration, the standard reference materials NCS DC 73332 and SRM620 as well as the reference materials AWI-1 and PRI-1 were analysed by micro-XRF. Elemental concentrations determined by the three analytical procedures (ICP-AES, micro-XRF on sherds and micro-XRF on pellets) were statistically treated by correlation analysis and Student's t-test (at the 95% confidence level)

  6. Comparison of a portable micro-X-ray fluorescence spectrometry with inductively coupled plasma atomic emission spectrometry for the ancient ceramics analysis

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulou, D.N. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece); Zachariadis, G.A. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece); Anthemidis, A.N. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece); Tsirliganis, N.C. [Archaeometry Laboratory, Cultural and Educational Technology Institute, Tsimiski 58, GR-67100, Xanthi (Greece); Stratis, J.A. [Laboratory of Analytical Chemistry, Faculty of Chemistry, Aristotle University, GR-54124, Thessaloniki (Greece)]. E-mail: jstratis@chem.auth.gr

    2004-12-01

    Two multielement instrumental methods of analysis, micro X-ray fluorescence spectrometry (micro-XRF) and inductively coupled plasma atomic emission spectrometry (ICP-AES) were applied for the analysis of 7th and 5th century B.C. ancient ceramic sherds in order to evaluate the above two methods and to assess the potential to use the current compact and portable micro-XRF instrument for the in situ analysis of ancient ceramics. The distinguishing factor of interest is that micro-XRF spectrometry offers the possibility of a nondestructive analysis, an aspect of primary importance in the compositional analysis of cultural objects. Micro-XRF measurements were performed firstly directly on the ceramic sherds with no special pretreatment apart from surface cleaning (micro-XRF on sherds) and secondly on pressed pellet disks which were prepared for each ceramic sherd (micro-XRF on pellet). For the ICP-AES determination of elements, test solutions were prepared by the application of a microwave-assisted decomposition procedure in closed high-pressure PFA vessels. Also, the standard reference material SARM 69 was used for the efficiency calibration of the micro-XRF instrument and was analysed by both methods. In order to verify the calibration, the standard reference materials NCS DC 73332 and SRM620 as well as the reference materials AWI-1 and PRI-1 were analysed by micro-XRF. Elemental concentrations determined by the three analytical procedures (ICP-AES, micro-XRF on sherds and micro-XRF on pellets) were statistically treated by correlation analysis and Student's t-test (at the 95% confidence level)

  7. Analysis of enantiomeric and non-enantiomeric monoterpenes in plant emissions using portable dynamic air sampling/solid-phase microextraction (PDAS-SPME) and chiral gas chromatography/mass spectrometry

    Science.gov (United States)

    Yassaa, Noureddine; Williams, Jonathan

    A portable dynamic air sampler (PDAS) using a porous polymer solid-phase microextraction (SPME) fibre has been validated for the determination of biogenic enantiomeric and non-enantiomeric monoterpenes in air. These compounds were adsorbed in the field, and then thermally desorbed at 250 °C in a gas chromatograph injector port connected via a β-cyclodextrin capillary separating column to a mass spectrometer. The optimized method has been applied for investigating the emissions of enantiomeric monoterpenes from Pseudotsuga menziesii (Douglas-fir), Rosmarinus officinalis (Rosemary) and Lavandula lanata (Lavender) which were selected as representative of coniferous trees and aromatic plants, respectively. The enantiomers of α-pinene, sabinene, camphene, δ-3-carene, β-pinene, limonene, β-phellandrene, 4-carene and camphor were successfully determined in the emissions from the three plants. While Douglas-fir showed a strong predominance toward (-)-enantiomers, Rosemary and Lavender demonstrated a large variation in enantiomeric distribution of monoterpenes. The simplicity, rapidity and sensitivity of dynamic sampling with porous polymer coated SPME fibres coupled to chiral capillary gas chromatography/mass spectrometry (GC/MS) makes this method potentially useful for in-field investigations of atmosphere-biosphere interactions and studies of optically explicit atmospheric chemistry.

  8. FeO "Orange Arc" Emission Detected in Optical Spectrum of Leonid Persistent Trains

    Science.gov (United States)

    Jenniskens, Peter; Lacey, Matt; Allan, Beverly J.; Self, Daniel E.; Plane, John M. C.; DeVincenzi, Donald L. (Technical Monitor)

    2000-01-01

    We report the detection of a broad continuum emission dominating the visual spectrum of a Leonid persistent train. A comparison with laboratory spectra of FeO 1 "orange arc" emission at I mbar shows a general agreement of the band position and shape. The detection of FeO confirms the classical mechanism of metal atom catalyzed recombination of ozone and oxygen atoms as the driving force behind optical emission from persistent trains. Sodium and iron atoms are now confirmed catalysts.

  9. Design of a portable optical emission tomography system for microwave induced compact plasma for visible to near-infrared emission lines

    Energy Technology Data Exchange (ETDEWEB)

    Rathore, Kavita, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in; Munshi, Prabhat, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in [Nuclear Engineering and Technology Programme, Indian Institute of Technology Kanpur, Kanpur (India); Bhattacharjee, Sudeep, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in [Department of Physics, Indian Institute of Technology Kanpur, Kanpur 208016 (India)

    2016-03-15

    A new non-invasive diagnostic system is developed for Microwave Induced Plasma (MIP) to reconstruct tomographic images of a 2D emission profile. A compact MIP system has wide application in industry as well as research application such as thrusters for space propulsion, high current ion beams, and creation of negative ions for heating of fusion plasma. Emission profile depends on two crucial parameters, namely, the electron temperature and density (over the entire spatial extent) of the plasma system. Emission tomography provides basic understanding of plasmas and it is very useful to monitor internal structure of plasma phenomena without disturbing its actual processes. This paper presents development of a compact, modular, and versatile Optical Emission Tomography (OET) tool for a cylindrical, magnetically confined MIP system. It has eight slit-hole cameras and each consisting of a complementary metal–oxide–semiconductor linear image sensor for light detection. The optical noise is reduced by using aspheric lens and interference band-pass filters in each camera. The entire cylindrical plasma can be scanned with automated sliding ring mechanism arranged in fan-beam data collection geometry. The design of the camera includes a unique possibility to incorporate different filters to get the particular wavelength light from the plasma. This OET system includes selected band-pass filters for particular argon emission 750 nm, 772 nm, and 811 nm lines and hydrogen emission H{sub α} (656 nm) and H{sub β} (486 nm) lines. Convolution back projection algorithm is used to obtain the tomographic images of plasma emission line. The paper mainly focuses on (a) design of OET system in detail and (b) study of emission profile for 750 nm argon emission lines to validate the system design.

  10. Elemental analysis using instrumental neutron activation analysis and inductively coupled plasma atomic emission spectrometry: a comparative study

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Choi, Kwang Soon; Moon, Jong Hwa; Kim, Sun Ha; Lim, Jong Myoung; Kim, Young Jin; Quraishi, Shamshad Begum

    2003-05-01

    Elemental analyses for certified reference materials were carried out using instrumental neutron activation analysis and inductively coupled plasma-atomic emission spectrometry. Five Certified Reference Materials (CRM) were selected for the study on comparative analysis of environmental samples. The CRM are Soil (NIST SRM 2709), Coal fly ash (NIST SRM 1633a), urban dust (NIST SRM 1649a) and air particulate on filter media (NIST SRM 2783 and human hair (GBW 09101)

  11. Quenching of the OH and nitrogen molecular emission by methane addition in an Ar capacitively coupled plasma to remove spectral interference in lead determination by atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Frentiu, T., E-mail: ftibi@chem.ubbcluj.r [Faculty of Chemistry and Chemical Engineering, Babes-Bolyai University, Arany Janos 11, 400028 Cluj-Napoca (Romania); Ponta, M., E-mail: mponta@chem.ubbcluj.r [Faculty of Chemistry and Chemical Engineering, Babes-Bolyai University, Arany Janos 11, 400028 Cluj-Napoca (Romania); Mihaltan, A.I., E-mail: alinblaj2005@yahoo.co [National Institute for Research and Development of Optoelectronics Bucharest - Research Institute for Analytical Instrumentation, Donath 67, 400293 Cluj-Napoca (Romania); Darvasi, E., E-mail: edarvasi@chem.ubbcluj.r [Faculty of Chemistry and Chemical Engineering, Babes-Bolyai University, Arany Janos 11, 400028 Cluj-Napoca (Romania); Frentiu, M., E-mail: frentiu.maria@yahoo.co [National Institute for Research and Development of Optoelectronics Bucharest - Research Institute for Analytical Instrumentation, Donath 67, 400293 Cluj-Napoca (Romania); Cordos, E., E-mail: emilcordos@gmail.co [National Institute for Research and Development of Optoelectronics Bucharest - Research Institute for Analytical Instrumentation, Donath 67, 400293 Cluj-Napoca (Romania)

    2010-07-15

    A new method is proposed to remove the spectral interference on elements in atomic fluorescence spectrometry by quenching of the molecular emission of the OH radical (A{sup 2{Sigma}+} {yields} X{sup 2{Pi}}) and N{sub 2} second positive system (C{sup 3{Pi}}{sub u} {yields} B{sup 3{Sigma}}{sub g}) in the background spectrum of medium power Ar plasmas. The experiments were carried out in a radiofrequency capacitively coupled plasma (275 W, 27.12 MHz) by CH{sub 4} addition. The quenching is the result of the high affinity of OH radical for a hydrogen atom from the CH{sub 4} molecule and the collisions of the second kind between nitrogen excited molecules and CH{sub 4}, respectively. The decrease of the emission of N{sub 2} second positive system in the presence of CH{sub 4} is also the result of the deactivation of the metastable argon atoms that could excite the nitrogen molecules. For flow rates of 0.7 l min{sup -1} Ar with addition of 7.5 ml min{sup -1} CH{sub 4}, the molecular emission of OH and N{sub 2} was completely removed from the plasma jet spectrum at viewing heights above 60 mm. The molecular emission associated to CH and CH{sub 2} species was not observed in the emission spectrum of Ar/CH{sub 4} plasma in the ultraviolet range. The method was experimented for the determination of Pb at 283.31 nm by atomic fluorescence spectrometry with electrodeless discharge lamp and a multichannel microspectrometer. The detection limit was 35 ng ml{sup -1}, 2-3 times better than in atomic emission spectrometry using the same plasma source, and similar to that in hollow cathode lamp microwave plasma torch atomic fluorescence spectrometry.

  12. Obsidian hydration profiles measured by sputter-induced optical emission.

    Science.gov (United States)

    Tsong, I S; Houser, C A; Yusef, N A; Messier, R F; White, W B; Michels, J W

    1978-07-28

    The variation of concentrations of hydrogen, sodium, potassium, lithium, calcium, magnesium, silicon, and aluminum as a function of depth in the hydration layer of obsidian artifacts has been determined by sputter-induced optical emission. The surface hydration is accompanied by dealkalization, and there is a buildup of alkaline earths, calcium and magnesium in the outermost layers. These results have clarified the phenomena underlying the obsidian hydration dating technique.

  13. Optical parametric amplification and oscillation assisted by low-frequency stimulated emission.

    Science.gov (United States)

    Longhi, Stefano

    2016-04-15

    Optical parametric amplification and oscillation provide powerful tools for coherent light generation in spectral regions inaccessible to lasers. Parametric gain is based on a frequency down-conversion process and, thus, it cannot be realized for signal waves at a frequency ω3 higher than the frequency of the pump wave ω1. In this Letter, we suggest a route toward the realization of upconversion optical parametric amplification and oscillation, i.e., amplification of the signal wave by a coherent pump wave of lower frequency, assisted by stimulated emission of the auxiliary idler wave. When the signal field is resonated in an optical cavity, parametric oscillation is obtained. Design parameters for the observation of upconversion optical parametric oscillation at λ3=465 nm are given for a periodically poled lithium-niobate (PPLN) crystal doped with Nd(3+) ions.

  14. Analysis of metals and phosphorus in biodiesel B100 from different feedstock using a Flow Blurring® multinebulizer in inductively coupled plasma-optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Avila Orozco, Francisco D. [Lab. FIA, Sección Química Analítica, INQUISUR (UNS-CONICET), Universidad Nacional del Sur, Avenida Alem 1253, B8000CPB, Bahía Blanca (Argentina); Kovachev, Nikolay; Aguirre Pastor, Miguel Ángel [Dpto. Química Analítica, Nutrición y Bromatología e Instituto Universitario de Materiales, Facultad de Ciencias, Universidad de Alicante, Apdo. 99, Alicante (Spain); Domini, Claudia E.; Fernández Band, Beatriz S. [Lab. FIA, Sección Química Analítica, INQUISUR (UNS-CONICET), Universidad Nacional del Sur, Avenida Alem 1253, B8000CPB, Bahía Blanca (Argentina); Canals Hernández, Antonio, E-mail: a.canals@ua.es [Dpto. Química Analítica, Nutrición y Bromatología e Instituto Universitario de Materiales, Facultad de Ciencias, Universidad de Alicante, Apdo. 99, Alicante (Spain)

    2014-05-01

    Highlights: • The elemental analysis of biodiesel by the proposed method is simple and fast. • Two-nozzles Flow Blurring® nebulizer allow to reduce the spectral interferences. • Two-nozzles Flow Blurring® nebulizer avoid the formation of carbon deposits. • The analysis may be carried out without any sample pretreatment. Abstract: A simple and fast method for determining the content of Na, K, Ca, Mg, P, and 20 heavy metals in biodiesel samples with inductively coupled plasma optical emission spectrometry (ICP OES) using a two-nozzle Flow Blurring® multinebulizer prototype and on-line internal standard calibration, are proposed. The biodiesel samples were produced from different feedstock such as sunflower, corn, soybean and grape seed oils, via a base catalyst transesterification. The analysis was carried out without any sample pretreatment. The standards and samples were introduced through one of the multinebulizer nozzles, while the aqueous solution containing yttrium as an internal standard was introduced through the second nozzle. Thus, the spectral interferences were compensated and the formation of carbon deposits on the ICP torch was prevented. The determination coefficients (R²) were greater than 0.99 for the studied analytes, in the range 0.21–14.75 mg kg⁻¹. Short-term and long-term precisions were estimated as relative standard deviation. These were acceptable, their values being lower than 10%. The LOQ for major components such as Ca, K, Mg, Na, and P, were within a range between 4.9 ng g⁻¹ for Mg (279.553 nm) and 531.1 ng g⁻¹ for Na (588.995 nm), and for the other 20 minor components they were within a range between 1.1 ng g⁻¹ for Ba (455.403 nm) and 2913.9 ng g⁻¹ for Pb (220.353 nm). Recovery values ranged between 95% and 106%.

  15. Investigation of an alternating current plasma as an element selective atomic emission detector for high-resolution capillary gas chromatography and as a source for atomic absorption and atomic emission spectrometry

    Science.gov (United States)

    Ombaba, Jackson M.

    This thesis deals with the construction and evaluation of an alternating current plasma (ACP) as an element-selective detector for high resolution capillary gas chromatography (GC) and as an excitation source for atomic absorption spectrometry (AAS) and atomic emission spectrometry (AES). The plasma, constrained in a quartz discharge tube at atmospheric pressure, is generated between two copper electrodes and utilizes helium as the plasma supporting gas. The alternating current plasma power source consists of a step-up transformer with a secondary output voltage of 14,000 V at a current of 23 mA. The device exhibits a stable signal because the plasma is self-seeding and reignites itself every half cycle. A tesla coil is not required to commence generation of the plasma if the ac voltage applied is greater than the breakdown voltage of the plasma-supporting gas. The chromatographic applications studied included the following: (1) the separation and selective detection of the organotin species, tributyltin chloride (TBT) and tetrabutyltin (TEBT), in environmental matrices including mussels (Mvutilus edullus) and sediment from Boston Harbor, industrial waste water and industrial sludge, and (2) the detection of methylcyclopentadienyl manganesetricarbonyl (MMT) and similar compounds used as gasoline additives. An ultrasonic nebulizer (common room humidifier) was utilized as a sample introduction device for aqueous solutions when the ACP was employed as an atomization source for atomic absorption spectrometry and as an excitation source for atomic emission spectrometry. Plasma diagnostic parameters studied include spatial electron number density across the discharge tube, electronic, excitation and ionization temperatures. Interference studies both in absorption and emission modes were also considered. Figures of merits of selected elements both in absorption and emission modes are reported. The evaluation of a computer-aided optimization program, Drylab GC, using

  16. Electron cyclotron emission from optically thin plasma in compact helical system

    International Nuclear Information System (INIS)

    Idei, Hiroshi; Kubo, Shin; Hosokawa, Minoru; Iguchi, Harukazu; Ohkubo, Kunizo; Sato, Teruyuki.

    1994-01-01

    A frequency spectrum of second harmonic electron cyclotron emission was observed for an optically thin plasma produced by fundamental electron cyclotron heating in a compact helical system. A radial electron temperature profile deduced from this spectrum neglecting the multiple reflections effect shows a clear difference from that measured by Thomson scattering. We relate the spectrum with the electron temperature profile by the modified emission model including the scrambling effect. The scrambling effect results from both mode conversion and change in the trajectory due to multiple reflections of the emitting ray at the vessel wall. The difference between the two temperature profiles is explained well by using the modified emission model. Reconstruction of the electron temperature profile from the spectrum using this model is also discussed. (author)

  17. Spectral analysis of optical emission of microplasma in sea water

    Science.gov (United States)

    Gamaleev, Vladislav; Morita, Hayato; Oh, Jun-Seok; Furuta, Hiroshi; Hatta, Akimitsu

    2016-09-01

    This work presents an analysis of optical emission spectra from microplasma in three types of liquid, namely artificial sea water composed of 10 typical agents (10ASW), reference solutions each containing a single agent (NaCl, MgCl2 + H2O, Na2SO4, CaCl2, KCl, NaHCO3, KBr, NaHCO3, H3BO3, SrCl2 + H2O, NaF) and naturally sampled deep sea water (DSW). Microplasma was operated using a needle(Pd)-to-plate(Pt) electrode system sunk into each liquid in a quartz cuvette. The radius of the tip of the needle was 50 μm and the gap between the electrodes was set at 20 μm. An inpulse generator circuit, consisting of a MOSFET switch, a capacitor, an inductor and the resistance of the liquid between the electrodes, was used as a pulse current source for operation of discharges. In the spectra, the emission peaks for the main components of sea water and contaminants from the electrodes were detected. Spectra for reference solutions were examined to enable the identification of unassigned peaks in the spectra for sea water. Analysis of the Stark broadening of H α peak was carried out to estimate the electron density of the plasma under various conditions. The characteristics of microplasma discharge in sea water and the analysis of the optical emission spectra will be presented. This work was supported by JSPS KAKENHI Grant Number 26600129.

  18. Assessment of high precision, high accuracy Inductively Coupled Plasma-Optical Emission Spectroscopy to obtain concentration uncertainties less than 0.2% with variable matrix concentrations

    International Nuclear Information System (INIS)

    Rabb, Savelas A.; Olesik, John W.

    2008-01-01

    The ability to obtain high precision, high accuracy measurements in samples with complex matrices using High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy (HP-ICP-OES) was investigated. The Common Analyte Internal Standard (CAIS) procedure was incorporated into the High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy method to correct for matrix-induced changes in emission intensity ratios. Matrix matching and standard addition approaches to minimize matrix-induced errors when using High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy were also assessed. The High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy method was tested with synthetic solutions in a variety of matrices, alloy standard reference materials and geological reference materials

  19. Rapid Multiwaveband Polarization Variability in the Quasar PKS 0420-014: Optical Emission from the Compact Radio Jet

    Science.gov (United States)

    D'Arcangelo, Francesca D.; Marscher, Alan P.; Jorstad, Svetlana G.; Smith, Paul S.; Larionov, Valeri M.; Hagen-Thorn, Vladimir A.; Kopatskaya, Eugenia N.; Williams, G. Grant; Gear, Walter K.

    2007-04-01

    An 11 day monitoring campaign in late 2005 reveals clear correlation in polarization between the optical emission and the region of the intensity peak (the ``pseudocore'') at the upstream end of the jet in 43 GHz VLBA (Very Long Baseline Array) images in the highly variable quasar PKS 0420-014. The electric-vector position angle (EVPA) of the pseudocore rotated by about 80° in four VLBA observations over a period of 9 days, matching the trend of the optical EVPA. In addition, the 43 GHz EVPAs agree well with the optical values when we correct the former for Faraday rotation. Fluctuations in the polarization at both wave bands are consistent with the variable emission arising from a standing conical shock wave that compresses magnetically turbulent plasma in the ambient jet. The volume of the variable component is the same at both wave bands, although only ~20% of the total 43 GHz emission arises from this site. The remainder of the 43 GHz flux density must originate in a separate region with very low polarization. If 0420-014 is a typical case, the nonthermal optical emission from blazars originates primarily in and near the pseudocore rather than closer to the central engine where the flow collimates and accelerates.

  20. Flagging and correcting non-spectral matrix interferences with spatial emission profiles and gradient dilution in inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Cheung, Yan; Schwartz, Andrew J.; Chan, George C.-Y.; Hieftje, Gary M.

    2015-01-01

    Matrix interference remains one of the most daunting challenges commonly encountered in inductively coupled plasma-atomic emission spectrometry (ICP-AES). In the present study, a method is described that enables identification and correction of matrix interferences in axial-viewed ICP-AES through a combination of spatial mapping and on-line gradient dilution. Cross-sectional emission maps of the plasma are used to indicate the presence of non-spectral (plasma-related and sample-introduction-related) matrix interferences. In particular, apparent concentrations of an analyte species determined at various radial locations in the plasma differ in the presence of a matrix interference, which allows the interference to be flagged. To correct for the interference, progressive, on-line dilution of the sample, performed by a gradient high-performance liquid-chromatograph pump, is utilized. The spatially dependent intensities of analyte emission are monitored at different levels of sample dilution. As the dilution proceeds, the matrix-induced signal variation is reduced. At a dilution where the determined concentrations become independent of location in the plasma, the matrix interference is minimized. - Highlights: • Non-spectral matrix interference in ICP-AES is flagged and minimized. • Emission from different locations of the plasma are collected simultaneously. • Spatially dependent determined concentrations indicate the presence of interference. • Gradient dilution is performed on both calibration standards and sample. • Optimal dilution factor to minimize interference is found as dilution increases

  1. Flagging and correcting non-spectral matrix interferences with spatial emission profiles and gradient dilution in inductively coupled plasma-atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Yan; Schwartz, Andrew J.; Chan, George C.-Y.; Hieftje, Gary M., E-mail: hieftje@indiana.edu

    2015-08-01

    Matrix interference remains one of the most daunting challenges commonly encountered in inductively coupled plasma-atomic emission spectrometry (ICP-AES). In the present study, a method is described that enables identification and correction of matrix interferences in axial-viewed ICP-AES through a combination of spatial mapping and on-line gradient dilution. Cross-sectional emission maps of the plasma are used to indicate the presence of non-spectral (plasma-related and sample-introduction-related) matrix interferences. In particular, apparent concentrations of an analyte species determined at various radial locations in the plasma differ in the presence of a matrix interference, which allows the interference to be flagged. To correct for the interference, progressive, on-line dilution of the sample, performed by a gradient high-performance liquid-chromatograph pump, is utilized. The spatially dependent intensities of analyte emission are monitored at different levels of sample dilution. As the dilution proceeds, the matrix-induced signal variation is reduced. At a dilution where the determined concentrations become independent of location in the plasma, the matrix interference is minimized. - Highlights: • Non-spectral matrix interference in ICP-AES is flagged and minimized. • Emission from different locations of the plasma are collected simultaneously. • Spatially dependent determined concentrations indicate the presence of interference. • Gradient dilution is performed on both calibration standards and sample. • Optimal dilution factor to minimize interference is found as dilution increases.

  2. Efficient trigger signal generation from wasted backward amplified stimulated emission at optical amplifiers for optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Kim Seung Taek

    2015-01-01

    Full Text Available This paper propose an optical structure to generate trigger signals for optical coherence tomography (OCT using backward light which is usually disposed. The backward light is called backward amplified stimulated emission generated from semiconductor optical amplifier (SOA when using swept wavelength tunable laser (SWTL. A circulator is applied to block undesirable lights in the SWTL instead of an isolator in common SWTL. The circulator also diverts backward amplified spontaneous lights, which finally bring out trigger signals for a high speed digitizer. The spectra of the forward lights at SOA and the waveform of the backward lights were measured to check the procedure of the trigger formation in the experiment. The results showed that the trigger signals from the proposed SWTL with the circulator was quite usable in OCT.

  3. Development of multilayer optics for X-ray broadband spectrometry of plasma emission

    International Nuclear Information System (INIS)

    Emprin, Benoit

    2014-01-01

    Within the framework of the research on inertial confinement fusion, the 'Commissariat a l'energie atomique et aux energies alternatives' has studied and implemented an absolute calibrated time-Resolved broadband soft x-Ray spectrometer, called 'Diagnostic de Mesure du rayonnement X'. This diagnostic, composed of 20 measurement channels, measures the emitted radiant power from a laser created plasma in the range from 50 eV to 20 keV. We have developed additional measurement channels to obtain redundancy and an improvement in measurement accuracy. The principle of these new channels is based on an original concept to obtain spectral bounded flat-Responses. Two channels have been developed for the 2 - 4 keV and 4 - 6 keV spectral ranges, using aperiodic multilayer mirrors made at the 'Laboratoire Charles Fabry' with Cr/Sc and Ni/W/SiC/W layers respectively. These mirrors were characterized at synchrotron radiation facilities and integrated into the spectrometer. The two new channels were used during laser-Plasma experimental campaigns at the OMEGA laser facility in Rochester (USA). This allowed us to determine directly the radiant power with only one measurement within a certain spectral band, and with a better precision when compared with using standard channels. The results, in good agreement with the standard measurement channels, allowed us to validate the use of aperiodic multilayer mirrors for X-Ray broadband spectrometry. (author) [fr

  4. Mechanism of current modulation by optic phonon emission in heterojunction tunneling experiments

    International Nuclear Information System (INIS)

    Hanna, C.B.; Hellman, E.S.; Laughlin, R.B.

    1985-01-01

    We explain recent observations by Hickmott et al. of sequential longitudinal optic phonon emission in tunneling currents of GaAs-Al/sub x/Ga/sub 1-x/As heterojunctions in terms of inhomogeneous tunneling and a magnetopolaronic mass correction. 16 refs., 13 figs

  5. Refinery evaluation of optical imaging to locate fugitive emissions.

    Science.gov (United States)

    Robinson, Donald R; Luke-Boone, Ronke; Aggarwal, Vineet; Harris, Buzz; Anderson, Eric; Ranum, David; Kulp, Thomas J; Armstrong, Karla; Sommers, Ricky; McRae, Thomas G; Ritter, Karin; Siegell, Jeffrey H; Van Pelt, Doug; Smylie, Mike

    2007-07-01

    Fugitive emissions account for approximately 50% of total hydrocarbon emissions from process plants. Federal and state regulations aiming at controlling these emissions require refineries and petrochemical plants in the United States to implement a Leak Detection and Repair Program (LDAR). The current regulatory work practice, U.S. Environment Protection Agency Method 21, requires designated components to be monitored individually at regular intervals. The annual costs of these LDAR programs in a typical refinery can exceed US$1,000,000. Previous studies have shown that a majority of controllable fugitive emissions come from a very small fraction of components. The Smart LDAR program aims to find cost-effective methods to monitor and reduce emissions from these large leakers. Optical gas imaging has been identified as one such technology that can help achieve this objective. This paper discusses a refinery evaluation of an instrument based on backscatter absorption gas imaging technology. This portable camera allows an operator to scan components more quickly and image gas leaks in real time. During the evaluation, the instrument was able to identify leaking components that were the source of 97% of the total mass emissions from leaks detected. More than 27,000 components were monitored. This was achieved in far less time than it would have taken using Method 21. In addition, the instrument was able to find leaks from components that are not required to be monitored by the current LDAR regulations. The technology principles and the parameters that affect instrument performance are also discussed in the paper.

  6. Analytical chemistry of actinides

    International Nuclear Information System (INIS)

    Chollet, H.; Marty, P.

    2001-01-01

    Different characterization methods specifically applied to the actinides are presented in this review such as ICP/OES (inductively coupled plasma-optical emission spectrometry), ICP/MS (inductively coupled plasma spectroscopy-mass spectrometry), TIMS (thermal ionization-mass spectrometry) and GD/OES (flow discharge optical emission). Molecular absorption spectrometry and capillary electrophoresis are also available to complete the excellent range of analytical tools at our disposal. (authors)

  7. Mathematical Modeling of Optical Radiation Emission as a Function of Welding Power during Gas Shielded Metal Arc Welding.

    Science.gov (United States)

    Bauer, Stefan; Janßen, Marco; Schmitz, Martin; Ott, Günter

    2017-11-01

    Arc welding is accompanied by intense optical radiation emission that can be detrimental not only for the welder himself but also for people working nearby or for passersby. Technological progress advances continuously in the field of joining, so an up-to-date radiation database is necessary. Additionally, many literature irradiance data have been measured for a few welding currents or for parts of the optical spectral region only. Within this paper, a comprehensive study of contemporary metal active gas, metal inert gas, and cold metal transfer welding is presented covering optical radiation emission from 200 up to 2,700 nm by means of (spectro-) radiometric measurements. The investigated welding currents range from 70 to 350 A, reflecting values usually applied in industry. Based upon these new irradiance data, three mathematical models were derived in order to describe optical radiation emission as a function of welding power. The linear, exponential, and sigmoidal emission models depend on the process variant (standard or pulsed) as well as on the welding material (mild and stainless steel, aluminum). In conjunction with the corresponding exposure limit values for incoherent optical radiation maximum permissible exposure durations were calculated as a function of welding power. Typical times are shorter than 1 s for the ultraviolet spectral region and range from 1 to 10 s for visible radiation. For the infrared regime, exposure durations are of the order of minutes to hours. Finally, a validation of the metal active gas emission models was carried out with manual arc welding.

  8. Optically active polyurethane@indium tin oxide nanocomposite: Preparation, characterization and study of infrared emissivity

    International Nuclear Information System (INIS)

    Yang, Yong; Zhou, Yuming; Ge, Jianhua; Yang, Xiaoming

    2012-01-01

    Highlights: ► Silane coupling agent of KH550 was used to connect the ITO and polyurethanes. ► Infrared emissivity values of the hybrids were compared and analyzed. ► Interfacial synergistic action and orderly secondary structure were the key factors. -- Abstract: Optically active polyurethane@indium tin oxide and racemic polyurethane@indium tin oxide nanocomposites (LPU@ITO and RPU@ITO) were prepared by grafting the organics onto the surfaces of modified ITO nanoparticles. LPU@ITO and RPU@ITO composites based on the chiral and racemic tyrosine were characterized by FT-IR, UV–vis spectroscopy, X-ray diffraction (XRD), SEM, TEM, and thermogravimetric analysis (TGA), and the infrared emissivity values (8–14 μm) were investigated in addition. The results indicated that the polyurethanes had been successfully grafted onto the surfaces of ITO without destroying the crystalline structure. Both composites possessed the lower infrared emissivity values than the bare ITO nanoparticles, which indicated that the interfacial interaction had great effect on the infrared emissivity. Furthermore, LPU@ITO based on the optically active polyurethane had the virtue of regular secondary structure and more interfacial synergistic actions between organics and inorganics, thus it exhibited lower infrared emissivity value than RPU@ITO based on the racemic polyurethane.

  9. RELATIVISTIC PLASMA AS THE DOMINANT SOURCE OF THE OPTICAL CONTINUUM EMISSION IN THE BROAD-LINE RADIO GALAXY 3C 120

    International Nuclear Information System (INIS)

    Leon-Tavares, J.; Lobanov, A. P.; Arshakian, T. G.; Chavushyan, V. H.; Doroshenko, V. T.; Sergeev, S. G.; Efimov, Y. S.; Nazarov, S. V.

    2010-01-01

    We report a relation between radio emission in the inner jet of the Seyfert galaxy 3C 120 and optical continuum emission in this galaxy. Combining the optical variability data with multi-epoch high-resolution very long baseline interferometry observations reveals that an optical flare rises when a superluminal component emerges into the jet, and its maxima is related to the passage of such component through the location of a stationary feature at a distance of ∼1.3 pc from the jet origin. This indicates that a significant fraction of the optical continuum produced in 3C 120 is non-thermal, and it can ionize material in a sub-relativistic wind or outflow. We discuss implications of this finding for the ionization and structure of the broad emission line region, as well as for the use of broad emission lines for determining black hole masses in radio-loud active galactic nucleus.

  10. Determination of trace amounts of cerium in paint by inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Wong, K.L.

    1981-01-01

    The determination of Ce in paint by inductively coupled plasma atomic emission spectrometry (ICP-OES) is described, and the detection limit of ICP-OES of 0.0004 ppM is compared with that of other methods. The effects of the major elemental components of paint, Si, Pb, Cr, and Na on the ICP-OES determination of Ce were studied. The interference of 400 ppM of the other ions on the determination of 10 ppM Ce was small (0 to 3% error). The method is applicable to the range of 0.2 to 700 ppM Ce

  11. Understanding the effects of potassium ferricyanide on lead hydride formation in tetrahydroborate system and its application for determination of lead in milk using hydride generation inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Deng, Biyang; Xu, Xiangshu; Xiao, Yan; Zhu, Pingchuan; Wang, Yingzi

    2015-01-01

    Highlights: • Proposed a novel explanation for plumbane generation. • Expounded the role of K 3 Fe(CN) 6 in plumbane generation. • Clarified the controversial aspects in the mechanism of K 3 Fe(CN) 6 enhancement. • Used X-ray diffractometry to analyze the intermediates. • Developed a method to analyze lead in milk using K 3 Fe(CN) 6 and K 4 Fe(CN) 6 as new additives. - Absract: To understand the formation of plumbane in the Pb II -NaBH 4 -K 3 Fe(CN) 6 system, the intermediate products produced in the reaction of lead(II) and NaBH 4 in the presence of K 3 Fe(CN) 6 were studied. The produced plumbane and elemental lead were measured through continuous flow hydride generation (HG)-inductively coupled plasma optical emission spectrometry (ICP OES) and X-ray diffraction spectrometry techniques, respectively. Based on the experimental results, the explanations can be depicted in the following steps: (1) plumbane and black lead sediment (black Pb) are formed in the reaction of lead(II) and NaBH 4 ; (2) the black Pb is oxidized by K 3 Fe(CN) 6 to form Pb 2 [Fe(CN) 6 ], which further reacts with NaBH 4 to form more plumbane and black Pb; and (3) another round starts in which the produced black Pb from the step 2 is then oxidized continuously by K 3 Fe(CN) 6 to form more Pb 2 [Fe(CN) 6 ] complex, which would produce more plumbane. In short, the black Pb and Pb 2 [Fe(CN) 6 ] complex are the key intermediate products for the formation of plumbane in the Pb II -NaBH 4 -K 3 Fe(CN) 6 system. Based on the enhancement effect of potassium ferricyanide and potassium ferrocyanide, a method was developed to analyze lead in milk with HG-ICP OES technique. The detection limit of the method was observed as 0.081 μg L −1 . The linearity range of lead was found between 0.3 and 50,000 μg L −1 with correlation coefficient of 0.9993. The recovery of lead was determined as 97.6% (n = 5) for adding 10 μg L −1 lead into the milk sample

  12. Measurement of fluorescence emission spectrum of few strongly driven atoms using an optical nanofiber.

    Science.gov (United States)

    Das, Manoj; Shirasaki, A; Nayak, K P; Morinaga, M; Le Kien, Fam; Hakuta, K

    2010-08-02

    We show that the fluorescence emission spectrum of few atoms can be measured by using an optical nanofiber combined with the optical heterodyne and photon correlation spectroscopy. The observed fluorescence spectrum of the atoms near the nanofiber shows negligible effects of the atom-surface interaction and agrees well with the Mollow triplet spectrum of free-space atoms at high excitation intensity.

  13. Rapid analysis of mixed waste samples via the optical emission from laser initiated microplasmas

    International Nuclear Information System (INIS)

    Barefield, J.E. II; Ferran, M.D.; Cremers, D.A.

    1993-01-01

    Wavelength resolved optical emission from laser initiated microplasmas in samples containing Pu, Am, Pb, Cr, and Be was used to determine elemental compositions. Traditionally, samples of this type are analyzed by neutron activation, X-ray fluorescence, atomic absorption (AA), inductively coupled plasma - atomic emission spectroscopy (ICP-AES), and inductively coupled plasma mass spectroscopy (ICP-MS). Analysis via the traditional analytical spectroscopic techniques involves extensive sample separation and preparation which results in the generation of significant quantities of additional waste. In the laser based method, little to no sample preparation is required. The method is essentially waste free since only a few micrograms of material is removed from the sample in the generation of the microplasma. Detection limits of the laser based method typically range between subppm to tens of ppM. In this report, the optical emission from samples containing Pu, Am, Pb, Cr, and Be will be discussed. we will also discuss the essential elements of the analysis method

  14. Optical field emission from resonant gold nanorods driven by femtosecond mid-infrared pulses

    Energy Technology Data Exchange (ETDEWEB)

    Kusa, F. [Department of Applied Physics, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei Tokyo 184-8588 (Japan); Institute of Industrial Science, the University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505 (Japan); Echternkamp, K. E.; Herink, G.; Ropers, C. [4th Physical Institute – Solids and Nanostructures, University of Göttingen, 37077 Göttingen (Germany); Ashihara, S., E-mail: ashihara@iis.u-tokyo.ac.jp [Institute of Industrial Science, the University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505 (Japan)

    2015-07-15

    We demonstrate strong-field photoelectron emission from gold nanorods driven by femtosecond mid-infrared optical pulses. The maximum photoelectron yield is reached at the localized surface plasmon resonance, indicating that the photoemission is governed by the resonantly-enhanced optical near-field. The wavelength- and field-dependent photoemission yield allows for a noninvasive determination of local field enhancements, and we obtain intensity enhancement factors close to 1300, in good agreement with finite-difference time domain computations.

  15. Relationships between Molecular Composition and Optical Properties of Dissolved Organic Matter

    Science.gov (United States)

    Cooper, W. T.; Tfaily, M.; Osborne, D.; Paul, A.; Podgorski, D. C.; Corbett, J.; Chanton, J.

    2009-12-01

    Our focus is on the relationships between the optical properties of dissolved organic matter (DOM) and its molecular composition. For example, we demonstrated that changes in the absorption and fluorescence characteristics of DOM in outwelling from Brazilian mangrove forests correlated with decreases in highly unsaturated organic compounds as DOM was transported from mangrove porewaters to the continental shelf. In that work we combined ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) that provided detailed compositional information with absorption and Excitation/Emission Matrix (EEM) spectroscopy This presentation will highlight new results utilizing the combination of optical spectroscopy and FT-ICR mass spectrometry to illuminate the processes which control DOM cycling. Our focus will be on the contributions of the heteroatom components of DOM (i.e. organic sulfur and organic nitrogen) to its optical properties and how changes in optical properties correlate with important environmental processes like humification and bioavailability. Figure 1 below includes a narrow 0.20 Dalton window from a mass spectrum which demonstrates the ability of ultrahigh resolution mass spectrometry to resolve and identify nitrogen heteroatom compounds in DOM. Our study sites include the Glacial Lake Agassiz Peatlands (GLAP) in northern Minnesota and wetlands in the Caloosahatchee River basin in South Florida. Figure 1. Isolated 0.20 Da window of an ESI-FT-ICR mass spectrum of DOM from a GLAP bog. Labels identify N1 (d,e,f) and N3 classes of nitrogen heteroatoms. The 0.0031 Da mass spacing is used to confirm the N3 class.

  16. Development of Exact Matrix-Matching Inductively Coupled Plasma-Optical Emission Spectroscopy for the Analysis of Cu and K in Infant Formula

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ye-Ji; Yim, Yong-Hyeon [University of Science and Technology, Daejeon (Korea, Republic of); Heo, Sung Woo; Han, Myung-Sub; Lim, Youngran [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2016-08-15

    In the present study, we have developed an exact matrix-matching inductively coupled plasma-optical emission spectroscopy (ICP-OES) as a low-cost alternative to the isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) method for accurate and precise measurements of nutrient elements K and Cu in infant formula. In spite of its high precision and accuracy, ICP-OES analysis of complex samples was not reliable due to biases originating from various matrix effects. The elaborated exact matrix-matching approach tested here demonstrated its potential to minimize biases due to matrix mismatch. The exact matrix-matching ICP-OES method was successfully validated by comparing the results with those from an isotope dilution ICP-M S method. Because the model provides reliable results without significant loss of precision, it will be an excellent choice for major element analysis in a complex sample, especially when isotope dilution is not applicable due to the l ck of alternative isotopes or the high cost of enriched isotopes.

  17. Scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDX) and aerosol time-of-flight mass spectrometry (ATOFMS) single particle analysis of metallurgy plant emissions

    International Nuclear Information System (INIS)

    Arndt, J.; Deboudt, K.; Anderson, A.; Blondel, A.; Eliet, S.; Flament, P.; Fourmentin, M.; Healy, R.M.; Savary, V.; Setyan, A.; Wenger, J.C.

    2016-01-01

    The chemical composition of single particles deposited on industrial filters located in three different chimneys of an iron-manganese (Fe–Mn) alloy manufacturing plant have been compared using aerosol time-of-flight mass spectrometry (ATOFMS) and scanning electron microscopy–energy dispersive X-ray spectrometry (SEM-EDX). Very similar types of particles were observed using both analytical techniques. Calcium-containing particles dominated in the firing area of the sintering unit, Mn and/or Al-bearing particles were observed at the cooling area of the sintering unit, while Mn-containing particles were dominant at the smelting unit. SEM-EDX analysis of particles collected downstream of the industrial filters showed that the composition of the particles emitted from the chimneys is very similar to those collected on the filters. ATOFMS analysis of ore samples was also performed to identify particulate emissions that could be generated by wind erosion and manual activities. Specific particle types have been identified for each emission source (chimneys and ore piles) and can be used as tracers for source apportionment of ambient PM measured in the vicinity of the industrial site. - Highlights: • Similar composition for emitted particles as those collected on the chimney filters. • Emitted particles dominated by Ca-, Mn and/or Al-containing particles. • Identification of specific particle types emitted by the different process units. - The particles emitted by metallurgy activities are fully described by ATOFMS and SEM-EDX, enabling the identification of specific particle types from the different units of the process.

  18. Application of Cathodoluminescence to The Study of Feldspars: Imaging and Spectrometry

    Science.gov (United States)

    Fonseca, Rute; Couto, Helena

    2017-12-01

    Cathodoluminescence (CL) studies were carried out on polished thin sections of different feldspar samples (from migmatites, granites, aplite-pegmatites and granitic aggregates) using a hot cathode CL equipment HC3-LM coupled to an optical microscope and to a spectrometer (SpectraPro 2300i and a CCD Pixis 400B detector and the software Winspec32) from the Faculty of Sciences of University of Porto. The system was operated at 14kV and a filament current of 0.18 mA. The samples were coated with a thin gold film using a Cressington 108 Auto device. Luminescence images were acquired during the CL analysis with an adapted digital video-camera (KAPPA PS 40C-285 (DX) with dual stage Peltier cooling) and an acquisition time between 351ms and 3,52s. The CL study, including imaging and spectrometry, proved to be an important tool to complement the feldspar petrography as it contributes to the identification of features not observed under optical microscope. The application of the Cathodoluminescence to feldspar allows distinguishing between potassic feldspar and plagioclase, differentiating generations of feldspar and displaying internal zoning and growth areas, among other. The spectrometry complements the CL imaging. It allows obtaining a qualitative level of emission intensity, which permits the interpretation of the nature of this luminescence in each feldspar. Bands shown in the spectra are related to the existing activator elements. In the present study, it was found an association of each feldspar to different spectra and respective colour. The plagioclases exhibit yellow or green luminescence. The activator element is Mn2+, showing a broad emission band between 550 - 570 nm specially detected on this type of feldspars, due to the replacement of K+ for Mn2+. The potassium feldspars have more or less intense blue colour associated with various activators elements: the activator element is Cu2+ showing a broad emission band between 420±5 nm. This emission band can be

  19. Time-of-flight positron emission tomography using optical fiber circuit

    International Nuclear Information System (INIS)

    Yamawaki, Masato; Katsumura, Yousuke; Suzuki, Takenori

    2008-01-01

    The measurement method and system architecture of a new time-of-flight positron emission tomography (TOF-PET) system are proposed. This system collects scintillation light using optical fibers connected directly to scintillators and measures the position of positron annihilation. Many scintillators are placed cylindrically whereby a pair of scintillators detects a pair of γ-rays generated at the positron annihilation point. Optical fiber circuits, most of which are bundles of optical fibers bound clockwise or counterclockwise around the cylinder of scintillators, collect light signals generated by γ-rays. These light signals are amplified by several photomultiplier tubes and processed using a single digital oscilloscope to determine the TOF of the positron annihilation γ-rays. One of the most important factors in the performance of the TOF-PET system is the TOF resolution. When fiber circuits are used for transmitting light signals, the dispersion of light signals and the decrease in light intensity are the major factors in the deterioration of the TOF resolution. The result of the preliminary experiment leads to the conclusion that the use of optical fibers degrades the intensity of light but does not severely degrade the TOF resolution. (author)

  20. Cu,Cr and As determination in preserved woods (Eucalyptus ssp.) by X-ray fluorescence spectrometries

    International Nuclear Information System (INIS)

    Pereira Junior, Sergio Matias

    2014-01-01

    Brazil produces around 2.2 millions of cubic meters of treated wood to meet the annual demand of railway, electric, rural and construction sectors. The most used wood species are eucalyptus (Eucalyptus ssp.) and pine (Pinus ssp.).The treated woods used for poles, sleepers, fence posts and plywoods should be according to Brazilian norms requirements. The most usual wood preservative products used in Brazil are CCA (chromated copper arsenate) and CCB (copper chromium and boron salt). The analytical methods, such as flame atomic absorption spectrometry (FAAS), plasma inductively coupled optical emission spectrometry (ICPOES) and X-ray fluorescence spectrometry (XRFS) have been used for the analytical control of those treatment processes. In this work, the eucalyptus trees (Eucalyptus ssp) samples was obtained from Minas Gerais State, Brazil, cut plantation areas. Under pressure, eucalyptus wood samples were submitted to different concentration of CCA solution reaching 3.9, 6.7, 9.1, 12.4 and 14.0 kg of CCA by m-³ sapwood retentions. Samples in cylinders and sawdust forms were obtained from treated wood samples. Copper, chromium and arsenic determination was performed using the energy dispersive X-ray fluorescence spectrometry (EDXRFS), portable X-ray fluorescence spectrometry (PXRFS), flame atomic absorption spectrometry (FAAS) and instrumental neutron activation analysis. In this work, the method of analysis, sensitivity, precision and accuracy performances of the related techniques were outlined. (author)

  1. Ten per cent polarized optical emission from GRB 090102.

    Science.gov (United States)

    Steele, I A; Mundell, C G; Smith, R J; Kobayashi, S; Guidorzi, C

    2009-12-10

    The nature of the jets and the role of magnetic fields in gamma-ray bursts (GRBs) remains unclear. In a baryon-dominated jet only weak, tangled fields generated in situ through shocks would be present. In an alternative model, jets are threaded with large-scale magnetic fields that originate at the central engine and that accelerate and collimate the material. To distinguish between the models the degree of polarization in early-time emission must be measured; however, previous claims of gamma-ray polarization have been controversial. Here we report that the early optical emission from GRB 090102 was polarized at 10 +/- 1 per cent, indicating the presence of large-scale fields originating in the expanding fireball. If the degree of polarization and its position angle were variable on timescales shorter than our 60-second exposure, then the peak polarization may have been larger than ten per cent.

  2. Noise-Immune Cavity-Enhanced Optical Heterodyne Molecular Spectrometry Modelling Under Saturated Absorption

    Science.gov (United States)

    Dupré, Patrick

    2015-06-01

    The Noise-Immune Cavity-Enhanced Optical Heterodyne Molecular Spectrometry (NICE-OHMS) is a modern technique renowned for its ultimate sensitivity, because it combines long equivalent absorption length provided by a high finesse cavity, and a detection theoretically limited by the sole photon-shot-noise. One fallout of the high finesse is the possibility to accumulating strong intracavity electromagnetic fields (EMF). Under this condition, molecular transitions can be easy saturated giving rise to the usual Lamb dips (or hole burning). However, the unusual shape of the basically trichromatic EMF (due to the RF lateral sidebands) induces nonlinear couplings, i.e., new crossover transitions. An analytical methodology will be presented to calculate spectra provided by NICE-OHMS experiments. It is based on the solutions of the equations of motion of an open two-blocked-level system performed in the frequency-domain (optically thin medium). Knowing the transition dipole moment, the NICE-OHMS signals (``absorption-like'' and ``dispersion-like'') can be simulated by integration over the Doppler shifts and by paying attention to the molecular Zeeman sublevels and to the EMF polarization The approach has been validated by discussion experimental data obtained on two transitions of {C2H2} in the near-infrared under moderated saturation. One of the applications of the saturated absorption is to be able to simultaneously determine the transition intensity and the density number while only one these 2 quantities can only be assessed in nonlinear absorption. J. Opt. Soc. Am. B 32, 838 (2015) Optics Express 16, 14689 (2008)

  3. Deuterium measurement by emission spectrometry

    International Nuclear Information System (INIS)

    Niemann, E.G.; Heilig, K.; Dumke, I.

    1978-01-01

    The method makes it possible to determine the relative deuterium content of enriched water samples. For this, the relative intensities of the Hα and Dα lines are measured which are emitted by a high-frequency discharge in water vapour. Although the method is not as exact as mass spectrometry, it has the following advantages: - Easy sample preparation (no reduction necessary); - samples of highly different enrichment can be measured one after the other without the danger of memory effects; - much lower apparatus and cost expenditure. The necessary sample size is about the same in both methods. (orig.) [de

  4. Optical emission spectroscopy of carbon laser plasma ion source

    Science.gov (United States)

    Balki, Oguzhan; Rahman, Md. Mahmudur; Elsayed-Ali, Hani E.

    2018-04-01

    Carbon laser plasma generated by an Nd:YAG laser (wavelength 1064 nm, pulse width 7 ns, fluence 4-52 J cm-2) is studied by optical emission spectroscopy and ion time-of-flight. Up to C4+ ions are detected with the ion flux strongly dependent on the laser fluence. The increase in ion charge with the laser fluence is accompanied by observation of multicharged ion lines in the optical spectra. The time-integrated electron temperature Te is calculated from the Boltzmann plot using the C II lines at 392.0, 426.7, and 588.9 nm. Te is found to increase from ∼0.83 eV for a laser fluence of 22 J cm-2 to ∼0.90 eV for 40 J cm-2. The electron density ne is obtained from the Stark broadened profiles of the C II line at 392 nm and is found to increase from ∼ 2 . 1 × 1017cm-3 for 4 J cm-2 to ∼ 3 . 5 × 1017cm-3 for 40 J cm-2. Applying an external electric field parallel to the expanding plume shows no effect on the line emission intensities. Deconvolution of ion time-of-flight signal with a shifted Maxwell-Boltzmann distribution for each charge state results in an ion temperature Ti ∼4.7 and ∼6.0 eV for 20 and 36 J cm-2, respectively.

  5. Laser ablation inductively coupled plasma optical emission spectrometry for analysis of pellets of plant materials

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Marcos S. [Departamento de Química, Universidade Federal de São Carlos, Rod. Washington Luís, km 235, 13565-905 São Carlos, SP (Brazil); Centro de Energia Nuclear na Agricultura, Universidade de São Paulo, Av. Centenário 303, 13416-000 Piracicaba, SP (Brazil); Schenk, Emily R. [Department of Chemistry and Biochemistry, Florida International University, Miami, FL (United States); International Forensic Research Institute, Florida International University, Miami, FL (United States); Santos, Dário [Departamento de Ciências Exatas e da Terra, Universidade Federal de São Paulo, Rua Professor Arthur Riedel 275, Diadema, SP (Brazil); Krug, Francisco José [Centro de Energia Nuclear na Agricultura, Universidade de São Paulo, Av. Centenário 303, 13416-000 Piracicaba, SP (Brazil); Almirall, José R., E-mail: almirall@fiu.edu [Department of Chemistry and Biochemistry, Florida International University, Miami, FL (United States); International Forensic Research Institute, Florida International University, Miami, FL (United States)

    2014-04-01

    An evaluation of laser ablation inductively coupled plasma optical emission spectroscopy (LAICP OES) for the direct analysis of pelleted plant material is reported. Ground leaves of orange citrus, soy and sugarcane were comminuted using a high-speed ball mill, pressed into pellets and sampled directly with laser ablation and analyzed by ICP OES. The limits of detection (LODs) for the method ranged from as low as 0.1 mg kg{sup −1} for Zn to as high as 94 mg kg{sup −1} for K but were generally below 6 mg kg{sup −1} for most of the elements of interest. A certified reference material consisting of a similar matrix (NIST SRM 1547 peach leaves) was used to check the accuracy of the calibration and the reported method resulted in an average bias of ∼ 5% for all the elements of interest. The precision for the reported method ranged from as low as 4% relative standard deviation (RSD) for Mn to as high as 17% RSD for Zn but averaged ∼ 6.5% RSD for all the elements (n = 10). The proposed method was tested for the determination of Ca, Mg, P, K, Fe, Mn, Zn and B, and the results were in good agreement with those obtained for the corresponding acid digests by ICP-OES, no differences being observed by applying a paired t-test at the 95% confidence level. The reported direct solid sampling method provides a fast alternative to acid digestion that results in similar and appropriate analytical figures of merit with regard to sensitivity, accuracy and precision for plant material analysis. - Highlights: • An evaluation of LA-ICP-OES for the direct analysis of pelleted plant material is reported. • Orange citrus, soy and sugarcane plants were pressed into pellets and sampled directly. • The element menu consisted of Ca, Mg, P, K, Fe, Mn, Zn and B. • LODs for the method ranged from 0.1 mg kg{sup −1} for Zn to 94 mg kg{sup −1} for K. • The precision ranged from 4% RSD for Mn to 17% RSD for Zn (∼ 6.5% RSD average)

  6. Comparison of 4 analytical techniques based on atomic spectrometry for the determination of total tin in canned foodstuffs

    OpenAIRE

    2011-01-01

    Abstract Different techniques for the determination of total tin in beverage and canned food by atomic spectrometry were compared. The performance characteristics of Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Hydride Generation Inductively Coupled Plasma Atomic Emission Spectrometry (HG-ICP-AES), Electrothermal Atomization Atomic Absorption Spectrometry (ETA-AAS) and Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) were determined in term of linearity, ...

  7. Spectrometry techniques for radioactivity measurements

    International Nuclear Information System (INIS)

    Anilkumar, S.

    2016-01-01

    The energy of the radiation emission following the nuclear decay is unique and the characteristic of the radio nuclide which undergoes decay. Thus measurement of the energy of the radiation offers a method of identifying the radio nuclides. The prime requirement of the energy measurement is a suitable detector which shows response proportional to the energy of the radiation rather than the presence of the radiation. The response from such detectors are suitably processed and distributed with respect to the signal strength which is proportional to incident energy. This distribution is normally referred as energy spectrum and is recorded in the multichannel analyser. The measurement of energy and intensity of radiation from the spectrum is called radiation spectrometry. Thus the radiation spectrometry allows the identification and quantification of radioactive isotopes in variety of matrices. The radiation spectrometry has now become a popular radioanalytical technique in wide area of nuclear fuel cycle programs. The popular spectrometry techniques commonly used for the radioactivity measurement and analysis are Alpha spectrometry, Gamma ray spectrometry and Beta spectrometry

  8. Assembly of positioner of automated two-dimensional scan coupled to X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Silva, Leonardo Santiago Melgaço

    2011-01-01

    This work describes the design and assembling of a prototype automated positioner two-dimensional scanning coupled to X-ray fluorescence spectrometry. The work aims to achieve a portable and easy to use, device of broad utility in the analysis of samples by X-ray fluorescence area of expertise and research. The two-dimensional scanning of the positioner is by means of two stepper motors controlled by a microcontroller PIC 16F877A, encoder and optical sensors. The user interacts with the XY table through an interface program for the Windows operating system, which communicates with the microcontroller through the serial port. The system of Fluorescence Spectroscopy incorporated into the positioner consists of a system commercially available system from the company AMPTEK, where the primary source of excitation of the sample was a source of 241 Am of 59.5 KeV emissions. Resolution and accuracy of tests were performed in the XY scanning process and reproducibility of the same kit with the fluorescence spectrometry X-ray. Qualitative tests by X-ray fluorescence spectrometry in samples were performed to demonstrate the applicability and versatility of the project. It follows that the prototype illustrates a possible adequately to portable device for X-ray spectrometry of two-dimensional. (author)

  9. Continuous-wave infrared optical gain and amplified spontaneous emission at ultralow threshold by colloidal HgTe quantum dots.

    Science.gov (United States)

    Geiregat, Pieter; Houtepen, Arjan J; Sagar, Laxmi Kishore; Infante, Ivan; Zapata, Felipe; Grigel, Valeriia; Allan, Guy; Delerue, Christophe; Van Thourhout, Dries; Hens, Zeger

    2018-01-01

    Colloidal quantum dots (QDs) raise more and more interest as solution-processable and tunable optical gain materials. However, especially for infrared active QDs, optical gain remains inefficient. Since stimulated emission involves multifold degenerate band-edge states, population inversion can be attained only at high pump power and must compete with efficient multi-exciton recombination. Here, we show that mercury telluride (HgTe) QDs exhibit size-tunable stimulated emission throughout the near-infrared telecom window at thresholds unmatched by any QD studied before. We attribute this unique behaviour to surface-localized states in the bandgap that turn HgTe QDs into 4-level systems. The resulting long-lived population inversion induces amplified spontaneous emission under continuous-wave optical pumping at power levels compatible with solar irradiation and direct current electrical pumping. These results introduce an alternative approach for low-threshold QD-based gain media based on intentional trap states that paves the way for solution-processed infrared QD lasers and amplifiers.

  10. Continuous-wave infrared optical gain and amplified spontaneous emission at ultralow threshold by colloidal HgTe quantum dots

    Science.gov (United States)

    Geiregat, Pieter; Houtepen, Arjan J.; Sagar, Laxmi Kishore; Infante, Ivan; Zapata, Felipe; Grigel, Valeriia; Allan, Guy; Delerue, Christophe; van Thourhout, Dries; Hens, Zeger

    2018-01-01

    Colloidal quantum dots (QDs) raise more and more interest as solution-processable and tunable optical gain materials. However, especially for infrared active QDs, optical gain remains inefficient. Since stimulated emission involves multifold degenerate band-edge states, population inversion can be attained only at high pump power and must compete with efficient multi-exciton recombination. Here, we show that mercury telluride (HgTe) QDs exhibit size-tunable stimulated emission throughout the near-infrared telecom window at thresholds unmatched by any QD studied before. We attribute this unique behaviour to surface-localized states in the bandgap that turn HgTe QDs into 4-level systems. The resulting long-lived population inversion induces amplified spontaneous emission under continuous-wave optical pumping at power levels compatible with solar irradiation and direct current electrical pumping. These results introduce an alternative approach for low-threshold QD-based gain media based on intentional trap states that paves the way for solution-processed infrared QD lasers and amplifiers.

  11. Optical properties of Nd3+ doped barium lithium fluoroborate glasses for near-infrared (NIR) emission

    Science.gov (United States)

    Mariselvam, K.; Arun Kumar, R.; Suresh, K.

    2018-04-01

    The neodymium doped barium lithium fluoroborate (Nd3+: BLFB) glasses with the chemical composition (70-x) H3BO3 - 10 Li2CO3 - 10 BaCO3- 5 CaF2-5 ZnO - x Nd2O3 (where x = 0.05, 0.1, 0.25, 0.5, 1, 2 in wt %) have been prepared by the conventional melt quenching technique and characterised through optical absorption, near infrared emission and decay-time measurements. The x-ray diffraction studies confirm the amorphous nature of the prepared glasses. The optical absorption spectra and emission spectra were recorded in the wavelength ranges of 190-1100 nm. The optical band gap (Eg) and Urbach energy (ΔE) values were calculated from the absorption spectra. The Judd-Ofelt intensity parameters were determined from the systematic analysis of the absorption spectrum of neodymium ions in the prepared glasses. The emission spectra exhibited three prominent peaks at 874, 1057, 1331 nm corresponding to the 4F3/2 → 4I9/2, 11/2, 13/2 transitions levels respectively in the near infrared region. The emission intensity of the 4F3/2 → 4I11/2 transition increases with the increase in neodymium concentration up to 0.5 wt% and the concentration quenching mechanism was observed for 1 wt% and 2 wt% concentrations. The lifetime of the 4F3/2 level was found to decrease with increasing Nd3+ ion concentration. The nature of energy transfer process was a single exponential curve which was studied for all the glasses and analysed.

  12. Surface emission of InxGa1-xN epilayers under strong optical excitation

    International Nuclear Information System (INIS)

    Jiang, H.X.; Lin, J.Y.; Khan, M.A.; Chen, Q.; Yang, J.W.

    1997-01-01

    Effects of strong optical excitation on the properties of surface emission from an InGaN/GaN heterostructure grown by metal-organic chemical-vapor deposition have been investigated. An intriguing feature observed was that as the excitation intensity increased the surface emission spectrum evolved abruptly from a single dominating band to two dominating bands at a critical intensity. This phenomenon has a sharp phase transition or a switching character and can be accounted for by (i) the formation of an electron endash hole plasma state in the InGaN vertical cavity under strong optical excitation, (ii) the photoreflectance effect (variation of index of refraction with excitation intensity), and (c) the Fabry endash Pacute erot interference effect in the InGaN vertical cavity. These findings are expected to have impact on the design of the laser structures, in particular on the design of the vertical-cavity surface-emitting laser diodes based on III-nitride wide-band-gap semiconductors. copyright 1997 American Institute of Physics

  13. Continuous-wave infrared optical gain and amplified spontaneous emission at ultralow threshold by colloidal HgTe quantum dots

    NARCIS (Netherlands)

    Geiregat, Pieter; Houtepen, Arjan J.; Sagar, Laxmi Kishore; Infante, Ivan; Zapata, Felipe; Grigel, Valeriia; Allan, Guy; Delerue, Christophe; Van Thourhout, Dries; Hens, Zeger

    2017-01-01

    Colloidal quantum dots (QDs) raise more and more interest as solution-processable and tunable optical gain materials. However, especially for infrared active QDs, optical gain remains inefficient. Since stimulated emission involves multifold degenerate band-edge states, population inversion can be

  14. Continuous-wave infrared optical gain and amplified spontaneous emission at ultralow threshold by colloidal HgTe quantum dots

    NARCIS (Netherlands)

    Geiregat, P.A.; Houtepen, A.J.; Sagar, Laxmi Kishore; Infante, Ivan; Zapata, Felipe; Grigel, Valeriia; Allan, Guy; Delerue, Christophe; Van Thourhout, Dries; Hens, Zeger

    2018-01-01

    Colloidal quantum dots (QDs) raise more and more interest as solution-processable and tunable optical gain materials. However, especially for infrared active QDs, optical gain remains inefficient. Since stimulated emission involves multifold degenerate band-edge states, population inversion can

  15. Chromatic-free spatially resolved optical emission spectroscopy diagnostics for microplasma

    International Nuclear Information System (INIS)

    Zhu Liguo; Chen Wencong; Zhu Ximing; Pu Yikang; Li Zeren

    2009-01-01

    A chromatic-free spatially resolved diagnostic system for microplasma measurement is proposed and demonstrated, which consists of an optical chromatic-free microscope mirror system, an electron multiplying charge coupled device (EMCCD), and bandpass filters. The diagnostic system free of chromatic aberrations with a spatial resolution of about 6 μm is achieved. The factors that limit the resolution of this diagnostic system have been analyzed, which are optical diffraction, the pixel size of the EMCCD, and the thickness of the microplasma. In this paper, the optimal condition for achieving a maximum resolution power has been analyzed. With this diagnostic system, we revealed the spatial nonuniformity of a microwave atmospheric-pressure argon microplasma. Furthermore, the spatial distribution of the time-averaged effective electron temperature has been estimated from the intensity distributions of 750.4 and 415.8 nm emissions.

  16. Fiber optical assembly for fluorescence spectrometry

    Science.gov (United States)

    Carpenter, II, Robert W.; Rubenstein, Richard; Piltch, Martin; Gray, Perry

    2010-12-07

    A system for analyzing a sample for the presence of an analyte in a sample. The system includes a sample holder for containing the sample; an excitation source, such as a laser, and at least one linear array radially disposed about the sample holder. Radiation from the excitation source is directed to the sample, and the radiation induces fluorescent light in the sample. Each linear array includes a plurality of fused silica optical fibers that receive the fluorescent light and transmits a fluorescent light signal from the first end to an optical end port of the linear array. An end port assembly having a photo-detector is optically coupled to the optical end port. The photo-detector detects the fluorescent light signal and converts the fluorescent light signal into an electrical signal.

  17. Glow Discharge Emission Spectrometry (GDOES): Theoretical Introduction, General Aspects, and its Applications within the Framework of the Technofusion Programs; Glow Discharge Emission Spectrometry (GDOES): Introduccion Teorica, Aspectos Generales y Aplicabilidad en el Marco del Programa Technofusion

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Rojo, A. B.; Gonzalez, M.; Tabares, F. L.

    2013-02-01

    The demand by material research groups for the direct composition analysis of solids is increasing as a solution to the time-consuming problems and errors inherent to classical chemical analysis, where the attack and solubilisation of the starting material is mandatory, often producing the introduction of impurities and component loss of the initial matrix. From the existing solid analysis techniques the present work is focused on the Glow Discharge Emission Spectrometry (GDOES), a fast, simply-executed technique, for which quantitative, high resolution depth profile determination of any element in the periodic table can be performed with a high sensibility and detection limit. The theoretical concepts, the required instrumentation and the basic analytic applications are revised, giving especial attention to the issues related to the analysis of materials for fusion applications. Finally, a comparative study with a more advanced spectroscopic technique (Secondary Ion Mass Spectrometry (SIMS)) is performed and the concomitance of both techniques to correct limitations such as the spatial resolution and the quantification of the analysis, important factors that are required in the chemical analysis of the complex materials used in Fusion, is addressed. (Author) 41 refs.

  18. Influence of sample temperature on the expansion dynamics and the optical emission of laser-induced plasma

    Energy Technology Data Exchange (ETDEWEB)

    Eschlböck-Fuchs, S.; Haslinger, M.J.; Hinterreiter, A.; Kolmhofer, P.; Huber, N. [Christian Doppler Laboratory for Laser-Assisted Diagnostics, Institute of Applied Physics, Johannes Kepler University Linz, A-4040 Linz (Austria); Rössler, R. [voestalpine Stahl GmbH, A-4031 Linz (Austria); Heitz, J. [Christian Doppler Laboratory for Laser-Assisted Diagnostics, Institute of Applied Physics, Johannes Kepler University Linz, A-4040 Linz (Austria); Pedarnig, J.D., E-mail: johannes.pedarnig@jku.at [Christian Doppler Laboratory for Laser-Assisted Diagnostics, Institute of Applied Physics, Johannes Kepler University Linz, A-4040 Linz (Austria)

    2013-09-01

    We investigate the influence of sample temperature on the dynamics and optical emission of laser induced plasma for various solid materials. Bulk aluminum alloy, silicon wafer, and metallurgical slag samples are heated to temperature T{sub S} ≤ 500 °C and ablated in air by Nd:YAG laser pulses (wavelength 1064 nm, pulse duration approx. 7 ns). The plasma dynamics is investigated by fast time-resolved photography. For laser-induced breakdown spectroscopy (LIBS) the optical emission of plasma is measured by Echelle spectrometers in combination with intensified CCD cameras. For all sample materials the temporal evolution of plume size and broadband plasma emission vary systematically with T{sub S}. The size and brightness of expanding plumes increase at higher T{sub S} while the mean intensity remains independent of temperature. The intensity of emission lines increases with temperature for all samples. Plasma temperature and electron number density do not vary with T{sub S}. We apply the calibration-free LIBS method to determine the concentration of major oxides in slag and find good agreement to reference data up to T{sub S} = 450 °C. The LIBS analysis of multi-component materials at high temperature is of interest for technical applications, e.g. in industrial production processes. - Highlights: • Size and emission of laser-induced plasma increase with sample temperature Ts. • Mean optical intensity of plasma is independent of Ts. • Plasma temperature and electron number density do not vary with Ts. • Major oxides in steel slag are quantified up to Ts = 450 °C. • Industrial steel slags are analyzed by calibration-free LIBS method.

  19. A photoionization model for the optical line emission from cooling flows

    Science.gov (United States)

    Donahue, Megan; Voit, G. M.

    1991-01-01

    The detailed predictions of a photoionization model previously outlined in Voit and Donahue (1990) to explain the optical line emission associated with cooling flows in X-ray emitting clusters of galaxies are presented. In this model, EUV/soft X-ray radiation from condensing gas photoionizes clouds that have already cooled. The energetics and specific consequences of such a model, as compared to other models put forth in the literature is discussed. Also discussed are the consequences of magnetic fields and cloud-cloud shielding. The results illustrate how varying the individual column densities of the ionized clouds can reproduce the range of line ratios observed and strongly suggest that the emission-line nebulae are self-irradiated condensing regions at the centers of cooling flows.

  20. Thermal effects on light emission in Yb3+ -sensitized rare-earth doped optical glasses

    International Nuclear Information System (INIS)

    Gouveia, E.A.; Araujo, M.T. de; Gouveia-Neto, A.S.

    2001-01-01

    The temperature effect upon infrared-to-visible frequency upconversion fluorescence emission in off-resonance infrared excited Yb 3+ -sensitized rare-earth doped optical glasses is theoretically and experimentally investigated. We have examined samples of Er3+/Yb 3+ -codoped Ga 2 S 3 :La 2 O 3 chalcogenide glasses and germanosilicate optical fibers, and Ga2O3:La 2 O 3 chalcogenide and fluoroindate glasses codoped with Pr 3+ /Yb 3+ , excited off-resonance at 1.064μm. The experimental results revealed thermal induced enhancement in the visible upconversion emission intensity as the samples temperatures were increased within the range of 20 deg C to 260 deg C. The fluorescence emission enhancement is attributed to the temperature dependent multiphonon-assisted anti-Stokes excitation process of the ytterbium-sensitizer. A theoretical approach that takes into account a sensitizer temperature dependent effective absorption cross section, which depends upon the phonon occupation number in the host matrices, has proven to agree very well with the experimental data. As beneficial applications of the thermal enhancement, a temperature tunable amplifier and a fiber laser with improved power performance are presented. (author)

  1. Metastable argon atom density in complex argon/acetylene plasmas determined by means of optical absorption and emission spectroscopy

    International Nuclear Information System (INIS)

    Sushkov, Vladimir; Herrendorf, Ann-Pierra; Hippler, Rainer

    2016-01-01

    Optical emission and absorption spectroscopy has been utilized to investigate the instability of acetylene-containing dusty plasmas induced by growing nano-particles. The density of Ar(1s 5 ) metastable atoms was derived by two methods: tunable diode laser absorption spectroscopy and with the help of the branching ratio method of emitted spectral lines. Results of the two techniques agree well with each other. The density of Ar(1s 3 ) metastable atoms was also measured by means of optical emission spectroscopy. The observed growth instability leads to pronounced temporal variations of the metastable and other excited state densities. An analysis of optical line ratios provides evidence for a depletion of free electrons during the growth cycle but no indication for electron temperature variations. (paper)

  2. A multiwavelength study of Swift GRB 060111B constraining the origin of its prompt optical emission

    Science.gov (United States)

    Stratta, G.; Pozanenko, A.; Atteia, J.-L.; Klotz, A.; Basa, S.; Gendre, B.; Verrecchia, F.; Boër, M.; Cutini, S.; Henze, M.; Holland, S.; Ibrahimov, M.; Ienna, F.; Khamitov, I.; Klose, S.; Rumyantsev, V.; Biryukov, V.; Sharapov, D.; Vachier, F.; Arnouts, S.; Perley, D. A.

    2009-09-01

    Context: The detection of bright optical emission measured with good temporal resolution during the prompt phase of GRB 060111Bmakes this GRB a rare event that is especially useful for constraining theories of the prompt emission. Aims: For this reason an extended multi-wavelength campaign was performed to further constrain the physical interpretation of the observations. Methods: In this work, we present the results obtained from our multi-wavelength campaign, as well as from the public Swift/BAT, XRT, and UVOT data. Results: We identified the host galaxy at R˜25 mag from deep R-band exposures taken 5 months after the trigger. Its featureless spectrum and brightness, as well as the non-detection of any associated supernova 16 days after the trigger, enabled us to constrain the distance scale of GRB 060111B11 within 0.4≤ z ≤3 in the most conservative case. The host galaxy spectral continuum is best fit with a redshift of z˜2, and other independent estimates converge to z˜1-2. From the analysis of the early afterglow SED, we find that non-negligible host galaxy dust extinction, in addition to the Galactic one, affects the observed flux in the optical regime. The extinction-corrected optical-to-gamma-ray SED during the prompt emission shows a flux density ratio Fγ/F_opt=10-2-10-4 with spectral index βγ,opt > βγ, strongly suggesting a separate origin of the optical and gamma-ray components. This result is supported by the lack of correlated behavior in the prompt emission light curves observed in the two energy domains. The temporal properties of the prompt optical emission observed during GRB 060111B11 and their similarities to other rapidly-observed events favor interpretation of this optical light as radiation from the reverse shock. Observations are in good agreement with theoretical expectations for a thick shell limit in slow cooling regime. The expected peak flux is consistent with the observed one corrected for the host extinction, likely

  3. A rapid excitation-emission matrix fluorometer utilizing supercontinuum white light and acousto-optic tunable filters

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wenbo [Imaging Unit, Integrative Oncology Department, BC Cancer Agency Research Center, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3 (Canada); Department of Dermatology and Skin Science, University of British Columbia, 835 West 10th Avenue, Vancouver, British Columbia V5Z 4E8 (Canada); Department of Biomedical Engineering, University of British Columbia, KAIS 5500, 2332 Main Mall, Vancouver, British Columbia V6T 1Z4 (Canada); Wu, Zhenguo; Zhao, Jianhua; Lui, Harvey; Zeng, Haishan, E-mail: hzeng@bccrc.ca [Imaging Unit, Integrative Oncology Department, BC Cancer Agency Research Center, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3 (Canada); Department of Dermatology and Skin Science, University of British Columbia, 835 West 10th Avenue, Vancouver, British Columbia V5Z 4E8 (Canada)

    2016-06-15

    Scanning speed and coupling efficiency of excitation light to optic fibres are two major technical challenges that limit the potential of fluorescence excitation-emission matrix (EEM) spectrometer for on-line applications and in vivo studies. In this paper, a novel EEM system, utilizing a supercontinuum white light source and acousto-optic tunable filters (AOTFs), was introduced and evaluated. The supercontinuum white light, generated by pumping a nonlinear photonic crystal fiber with an 800 nm femtosecond laser, was efficiently coupled into a bifurcated optic fiber bundle. High speed EEM spectral scanning was achieved using AOTFs both for selecting excitation wavelength and scanning emission spectra. Using calibration lamps (neon and mercury argon), wavelength deviations were determined to vary from 0.18 nm to −0.70 nm within the spectral range of 500–850 nm. Spectral bandwidth for filtered excitation light broadened by twofold compared to that measured with monochromatic light between 650 nm and 750 nm. The EEM spectra for methanol solutions of laser dyes were successfully acquired with this rapid fluorometer using an integration time of 5 s.

  4. A rapid excitation-emission matrix fluorometer utilizing supercontinuum white light and acousto-optic tunable filters

    International Nuclear Information System (INIS)

    Wang, Wenbo; Wu, Zhenguo; Zhao, Jianhua; Lui, Harvey; Zeng, Haishan

    2016-01-01

    Scanning speed and coupling efficiency of excitation light to optic fibres are two major technical challenges that limit the potential of fluorescence excitation-emission matrix (EEM) spectrometer for on-line applications and in vivo studies. In this paper, a novel EEM system, utilizing a supercontinuum white light source and acousto-optic tunable filters (AOTFs), was introduced and evaluated. The supercontinuum white light, generated by pumping a nonlinear photonic crystal fiber with an 800 nm femtosecond laser, was efficiently coupled into a bifurcated optic fiber bundle. High speed EEM spectral scanning was achieved using AOTFs both for selecting excitation wavelength and scanning emission spectra. Using calibration lamps (neon and mercury argon), wavelength deviations were determined to vary from 0.18 nm to −0.70 nm within the spectral range of 500–850 nm. Spectral bandwidth for filtered excitation light broadened by twofold compared to that measured with monochromatic light between 650 nm and 750 nm. The EEM spectra for methanol solutions of laser dyes were successfully acquired with this rapid fluorometer using an integration time of 5 s.

  5. Larger red-shift in optical emissions obtained from the thin films of globular proteins (BSA, lysozyme) – polyelectrolyte (PAA) complexes

    Energy Technology Data Exchange (ETDEWEB)

    Talukdar, Hrishikesh [Physical Sciences Division, Institute of Advanced Study in Science and Technology, Vigyan Path, Paschim Boragaon, Garchuk, Guwahati 781035, Assam (India); Kundu, Sarathi, E-mail: sarathi.kundu@gmail.com [Physical Sciences Division, Institute of Advanced Study in Science and Technology, Vigyan Path, Paschim Boragaon, Garchuk, Guwahati 781035, Assam (India); Basu, Saibal [Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2016-09-30

    Graphical abstract: Thin films of protein-polyelectrolyte complexes show larger red-shift in optical emission. - Highlights: • Globular proteins (lysozyme and BSA) and polyelectrolyte (sodium polyacrylic acid) are used to form protein-polyelectrolyte complexes (PPC). • Larger red-shift in optical emission is obtained from the thin films of PPC. • Red-shift is not obtained from the solution of PPC and pure protein thin films. • Larger red-shift from PPC films is due to the energy dissipation as non-radiative form through interactions with nearby atoms. • Red-shift in optical emission is independent on the thickness of the PPC film. - Abstract: Globular proteins (lysozyme and BSA) and polyelectrolyte (sodium polyacrylic acid) are used to form protein-polyelectrolyte complexes (PPC). Out-of-plane structures of ≈30–60 nm thick PPC films and their surface morphologies have been studied by using X-ray reflectivity and atomic force microscopy, whereas optical behaviors of PPC and protein conformations have been studied by using UV–vis, photoluminescence and FTIR spectroscopy respectively. Our study reveals that thin films of PPC show a larger red-shift of 23 and 16 nm in the optical emissions in comparison to that of pure protein whereas bulk PPC show a small blue-shift of ≈3 nm. A small amount of peak-shift is found to occur due to the heat treatment or concentration variation of the polyelectrolyte/protein in bulk solution but cannot produce such film thickness independent larger red-shift. Position of the emission peak remains nearly unchanged with the film thickness. Mechanism for such larger red-shift has been proposed.

  6. Emission Spectroscopy of the Interior of Optically Dense Post-Detonation Fireballs

    Science.gov (United States)

    2013-03-01

    sample. Light from the fiber optics was sent to spectrograph located in a shielded observation room several meters away from the explosive charge. The...spectrograph was constructed from a 1/8 m spectrometer (Oriel) interfaced to a 4096 pixel line-scan camera (Basler Sprint ) with a data collection rate... 400 ) 45 4000 (200) … FIG. 3. Time-resolved emission spectra obtained from detonation of 20 g charges of RDX containing 20 wt. % aluminum nanoparticles

  7. Detailed EXOSAT and optical observations of the intermediate polar 3A0729+103: discovery of two medium energy X-ray emission regions

    International Nuclear Information System (INIS)

    McHardy, I.M.; Pye, J.P.; Fairall, A.P.; Menzies, J.W.

    1987-01-01

    EXOSAT observations of the intermediate polar cataclysmic variable 3A0729+103 reveal a strong orbital modulation, with the 2-4KeV X-rays being significantly more modulated than the 4-6keV X-rays, indicative of photoelectric absorption. The 913 second modulation which is very prominent in the optical light curve, is weakly detected in the medium-energy X-ray light curve, confirming that it represents the white dwarf spin period. These observations are well explained by a combination of two sources of medium-energy X-ray emission. The presence of two emission regions is also clearly seen in the optical spectroscopy, particularly in the intensity of the He II4686 line which has two peaks during the orbit. The authors identify the two optical emission regions with the two X-ray emission regions. (author)

  8. Some metals determination in beers by atomic emission spectrometry of induced argon plasma

    International Nuclear Information System (INIS)

    Matsushige, I.

    1990-01-01

    It was made the identification and determination of metals in brazilian bottled and canned beer, using atomic emission spectrometry with d.c. are and argon coupled plasma excitation sources. The elements Co, Cr, Cu, Fe, Pb and Zn were determined in beer samples, after treatment with HNO sub(3) conc. /H sub(2) O sub(2) (30%). In the determination of Co, Cr, Cu, Pb and Zn and alternative method using HNO sub(3) conc. /O sub(3) was proved be useful. The results obtained for Co, Cr, Cu, Fe, Pb and Zn were below the limits established by brazilian legislation, showing the good quality of the beer concerning the metals. The results of this work were requested by the previous Ministerio do Meio Ambiente e Urbanismo in order to contribute to review the brazilian legislation in foods and beverages about metals contents. (author)

  9. Direct determination of sodium, potassium, chromium and vanadium in biodiesel fuel by tungsten coil atomic emission spectrometry

    International Nuclear Information System (INIS)

    Dancsak, Stacia E.; Silva, Sidnei G.; Nóbrega, Joaquim A.; Jones, Bradley T.; Donati, George L.

    2014-01-01

    Graphical abstract: -- Highlights: •Direct analysis of biodiesel on a tungsten coil atomizer. •Determination of Na, K, Cr and V by tungsten coil atomic emission spectrometry. •Sample dilution with methanol or ethanol. •Ten-microliter sample aliquots and limits of detection between 20 and 90 μg kg −1 . •Low consumption of reagents, samples and gases in a 140 s per run procedure. -- Abstract: High levels of sodium and potassium can be present in biodiesel fuel and contribute to corrosion, reduced performance and shorter engine lifetime. On the other hand, trace amounts of chromium and vanadium can increase the emission of pollutants during biodiesel combustion. Sample viscosity, immiscibility with aqueous solutions and high carbon content can compromise biodiesel analyzes. In this work, tungsten filaments extracted from microscope light bulbs are used to successively decompose biodiesel's organic matrix, and atomize and excite the analytes to determine sodium, potassium, chromium and vanadium by tungsten coil atomic emission spectrometry (WCAES). No sample preparation other than simple dilution in methanol or ethanol is required. Direct analysis of 10-μL sample aliquots using heating cycles with less than 150 s results in limits of detection (LOD) as low as 20, 70, 70 and 90 μg kg −1 for Na, K, Cr and V, respectively. The procedure's accuracy is checked by determining Na and K in a biodiesel reference sample and carrying out spike experiments for Cr and V. No statistically significant differences were observed between reference and determined values for all analytes at a 95% confidence level. The procedure was applied to three different biodiesel samples and concentrations between 6.08 and 95.6 mg kg −1 for Na and K, and between 0.22 and 0.43 mg kg −1 for V were obtained. The procedure is simple, fast and environmentally friendly. Small volumes of reagents, samples and gases are used and no residues are generated. Powers of detection are

  10. Direct determination of sodium, potassium, chromium and vanadium in biodiesel fuel by tungsten coil atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dancsak, Stacia E. [Department of Chemistry, Wake Forest University, Winston-Salem, NC 27109 (United States); Silva, Sidnei G.; Nóbrega, Joaquim A. [Group of Applied Instrumental Analysis, Department of Chemistry, Federal University of São Carlos, São Carlos, SP (Brazil); Jones, Bradley T. [Department of Chemistry, Wake Forest University, Winston-Salem, NC 27109 (United States); Donati, George L., E-mail: georgedonati@yahoo.com.br [Department of Chemistry, Wake Forest University, Winston-Salem, NC 27109 (United States)

    2014-01-02

    Graphical abstract: -- Highlights: •Direct analysis of biodiesel on a tungsten coil atomizer. •Determination of Na, K, Cr and V by tungsten coil atomic emission spectrometry. •Sample dilution with methanol or ethanol. •Ten-microliter sample aliquots and limits of detection between 20 and 90 μg kg{sup −1}. •Low consumption of reagents, samples and gases in a 140 s per run procedure. -- Abstract: High levels of sodium and potassium can be present in biodiesel fuel and contribute to corrosion, reduced performance and shorter engine lifetime. On the other hand, trace amounts of chromium and vanadium can increase the emission of pollutants during biodiesel combustion. Sample viscosity, immiscibility with aqueous solutions and high carbon content can compromise biodiesel analyzes. In this work, tungsten filaments extracted from microscope light bulbs are used to successively decompose biodiesel's organic matrix, and atomize and excite the analytes to determine sodium, potassium, chromium and vanadium by tungsten coil atomic emission spectrometry (WCAES). No sample preparation other than simple dilution in methanol or ethanol is required. Direct analysis of 10-μL sample aliquots using heating cycles with less than 150 s results in limits of detection (LOD) as low as 20, 70, 70 and 90 μg kg{sup −1} for Na, K, Cr and V, respectively. The procedure's accuracy is checked by determining Na and K in a biodiesel reference sample and carrying out spike experiments for Cr and V. No statistically significant differences were observed between reference and determined values for all analytes at a 95% confidence level. The procedure was applied to three different biodiesel samples and concentrations between 6.08 and 95.6 mg kg{sup −1} for Na and K, and between 0.22 and 0.43 mg kg{sup −1} for V were obtained. The procedure is simple, fast and environmentally friendly. Small volumes of reagents, samples and gases are used and no residues are generated

  11. Non linear optical investigations of silver nanoparticles synthesised by curcumin reduction

    Science.gov (United States)

    Dhanya, N. P.

    2017-11-01

    Metal nanoparticles have considerable applications in assorted fields like medicine, biology, photonics, metallurgy etc. Optical applications of Silver nanoparticles are of significant interest among researchers nowadays. In this paper, we report a single step chemical reduction of silver nanoparticles with Curcumin both as a reducing and stabilising agent at room temperature. Structural, plasmonic and non linear optical properties of the prepared nanoparticles are explored using Scanning Electron Microscope, Transmission Electron Microscope, UV absorption spectrometry, Spectroflurometry and Z scan. UV-Vis absorption studies affirm the Surface Plasmon Resonance (SPR) absorption and spectroflurometric studies announce the emission spectrum of the prepared silvernanoparticles at 520 nm. SEM and TEM images uphold the existence of uniform sized, spherical silvernanoparticles. Nonlinear optical studies are accomplished with the open aperture z scan technique in the nanosecond regime. The nonlinearity is in virtue of saturable absorption, two-photon absorption and excited state absorption. The marked nonlinearity and optical limiting of the Curcumin reduced silvernanoparticles enhances its photonic applications.

  12. Monitoring of Emissions From a Refinery Tank Farm Using a Combination of Optical Remote Sensing Techniques

    Science.gov (United States)

    Polidori, A.; Tisopulos, L.; Pikelnaya, O.; Mellqvist, J.; Samuelsson, J.; Marianne, E.; Robinson, R. A.; Innocenti, F.; Finlayson, A.; Hashmonay, R.

    2016-12-01

    Despite great advances in reducing air pollution, the South Coast Air Basin (SCAB) still faces challenges to attain federal health standards for air quality. Refineries are large sources of ozone precursors and, hence contribute to the air quality problems of the region. Additionally, petrochemical facilities are also sources of other hazardous air pollutants (HAP) that adversely affect human health, for example aromatic hydrocarbons. In order to assure safe operation, decrease air pollution and minimize population exposure to HAP the South Coast Air Quality Management District (SCAQMD) has a number of regulations for petrochemical facilities. However, significant uncertainties still exist in emission estimates and traditional monitoring techniques often do not allow for real-time emission monitoring. In the fall of 2015 the SCAQMD, Fluxsense Inc., the National Physical Laboratory (NPL), and Atmosfir Optics Ltd. conducted a measurement study to characterize and quantify gaseous emissions from the tank farm of one of the largest oil refineries in the SCAB. Fluxsense used a vehicle equipped with Solar Occultation Flux (SOF), Differential Optical Absorption Spectroscopy (DOAS), and Extractive Fourier Transform Infrared (FTIR) spectroscopy instruments. Concurrently, NPL operated their Differential Absorption Lidar (DIAL) system. Both research groups quantified emissions from the entire tank farm and identified fugitive emission sources within the farm. At the same time, Atmosfir operated an Open Path FTIR (OP-FTIR) spectrometer along the fenceline of the tank farm. During this presentation we will discuss the results of the emission measurements from the tank farm of the petrochemical facility. Emission rates resulting from measurements by different ORS methods will be compared and discussed in detail.

  13. Time-resolved measurement of emission profiles in pulsed radiofrequency glow discharge optical emission spectroscopy: Investigation of the pre-peak

    International Nuclear Information System (INIS)

    Alberts, D.; Horvath, P.; Nelis, Th.; Pereiro, R.; Bordel, N.; Michler, J.; Sanz-Medel, A.

    2010-01-01

    Radiofrequency glow discharge coupled to optical emission spectroscopy has been used in pulsed mode in order to perform a detailed study of the measured temporal emission profiles for a wide range of copper transitions. Special attention has been paid to the early emission peak (or so-called pre-peak), observed at the beginning of the emission pulse profile. The effects of the important pulse parameters such as frequency, duty cycle, pulse width and power-off time, have been studied upon the Cu pulse emission profiles. The influence of discharge parameters, such as pressure and power, was studied as well. Results have shown that the intensity observed in the pre-peak can be 10 times as large as the plateau value for resonant lines and up to 5 times in case of transitions to the metastable levels. Increasing pressure or power increased the pre-peak intensity while its appearance in time changed. The pre-peak decreased when the discharge off-time was shorter than 100 μs. According to such results, the presence of the pre-peak could be probably due to the lack of self-absorption during the first 50 μs, and not to the ignition of the plasma. Under the selected operation conditions, the use of the pre-peak emission as analytical signals increases the linearity of calibration curves for resonant lines subjected to self-absorption at high concentrations.

  14. Time-resolved measurement of emission profiles in pulsed radiofrequency glow discharge optical emission spectroscopy: Investigation of the pre-peak

    Energy Technology Data Exchange (ETDEWEB)

    Alberts, D. [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain); Horvath, P. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Feuerwerkerstrasse 39, 3602 Thun (Switzerland); Nelis, Th. [LAPLACE, Universite Paul Sabatier, 118 rte de Narbonne, Bat3R2, 31062 Toulouse Cedex (France); CU Jean Francois Champollion, Place de Verdun 81012 Albi Cedex 9 (France); Pereiro, R. [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain); Bordel, N. [Department of Physics, Faculty of Science, University of Oviedo, Calvo Sotelo, 33007 Oviedo (Spain); Michler, J. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Feuerwerkerstrasse 39, 3602 Thun (Switzerland); Sanz-Medel, A., E-mail: asm@uniovi.e [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain)

    2010-07-15

    Radiofrequency glow discharge coupled to optical emission spectroscopy has been used in pulsed mode in order to perform a detailed study of the measured temporal emission profiles for a wide range of copper transitions. Special attention has been paid to the early emission peak (or so-called pre-peak), observed at the beginning of the emission pulse profile. The effects of the important pulse parameters such as frequency, duty cycle, pulse width and power-off time, have been studied upon the Cu pulse emission profiles. The influence of discharge parameters, such as pressure and power, was studied as well. Results have shown that the intensity observed in the pre-peak can be 10 times as large as the plateau value for resonant lines and up to 5 times in case of transitions to the metastable levels. Increasing pressure or power increased the pre-peak intensity while its appearance in time changed. The pre-peak decreased when the discharge off-time was shorter than 100 {mu}s. According to such results, the presence of the pre-peak could be probably due to the lack of self-absorption during the first 50 {mu}s, and not to the ignition of the plasma. Under the selected operation conditions, the use of the pre-peak emission as analytical signals increases the linearity of calibration curves for resonant lines subjected to self-absorption at high concentrations.

  15. Elastic strain engineering of quantum dot excitonic emission in nanomembranes and optical resonators

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Plumhof, Johannes; Rastelli, Armando; Schmidt, Oliver [Institute for Integrative Nanosciences, IFW Dresden (Germany); Singh, Ranber; Zander, Tim; Bester, Gabriel [Max-Planck-Institut fuer Festkoerperforschung, Stuttgart (Germany)

    2010-07-01

    We study the effect of an external biaxial stress on the light emission of single InGaAs/GaAs(001) quantum dots (QD) embedded in a 200 nm-thick-membrane. Reversible and bi-directional spectral tuning of QD excitonic emission is demonstrated via a simple electro-mechanical device. The most intriguing finding is that biaxial strain is a reliable tool to engineer the QD electronic structure and reach color coincidence between exciton and biexciton emission, providing a vital prerequisite for the generation of polarization entangled photon pairs through a time reordering strategy. The physical origin of this new phenomenon is discussed based on the empirical pseudopotential calculations. With similar technique we study the effect of biaxial stress on single QDs embedded in microring resonators. The microrings can be reversibly stretched or squeezed, resulting in a controllable engineering of both QD emissions and optical modes. Our results open up a new tuning strategy to study cQED with semiconductor quantum dots.

  16. Application of factorial designs and Doehlert matrix in optimization of experimental variables associated with the preconcentration and determination of vanadium and copper in seawater by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Ferreira, Sergio L.C.; Queiroz, Adriana S.; Fernandes, Marcelo S.; Santos, Hilda C. dos

    2002-01-01

    In the present paper a procedure for preconcentration and determination of vanadium and copper in seawater using inductively coupled plasma optical emission spectrometry (ICP OES) is proposed, which is based on solid-phase extraction of vanadium (IV), vanadium (V) and copper (II) ions as 1-(2-pyridylazo)-2-naphthol (PAN) complexes by active carbon. The optimization process was carried out using two-level full factorials and Doehlert matrix designs. Four variables (PAN mass, pH, active carbon mass and shaking time) were regarded as factors in the optimization. Results of the two-level full factorial design 2 4 with 16 runs for vanadium extraction, based on the variance analysis (ANOVA), demonstrated that the factors pH and active carbon mass, besides the interaction (pHxactive carbon mass), are statistically significant. For copper, the ANOVA revealed that the factors PAN mass, pH and active carbon mass and the interactions (PAN massxpH) and (pHxactive carbon mass) are statistically significant. Doehlert designs were applied in order to determine the optimum conditions for extraction. The procedure proposed allowed the determination of vanadium and copper with detection limits (3σ/S) of 73 and 94 ng l -1 , respectively. The precision, calculated as relative standard deviation (R.S.D.), was 1.22 and 1.37% for 12.50 μg l -1 of vanadium and copper, respectively. The preconcentration factor was 80. The recovery achieved for determination of vanadium and copper in the presence of several cations demonstrated that this procedure improved the selectivity required for seawater analysis. The procedure was applied to the determination of vanadium and copper in seawater samples collected in Salvador City, Brazil. Results showed good agreement with other data reported in the literature

  17. A Simple But Comprehensive Methodology To Determine Gas-Phase Emissions Of Motor Vehicles With Extractive FTIR Spectrometry

    Science.gov (United States)

    Reyes, F. M.; Jaczilevich, A.; Grutter, M. A.; Huerta, M. A.; Rincón, P.; Rincón, R.; González, R.

    2004-12-01

    In this contribution, a methodology to acquire valuable information on the chemical composition and evolution of vehicular emissions is presented. With this innovative experimental set-up, it is possible to obtain real-time emissions of the combustion products without the need of dilution or sample collection. Key pollutants such as CO, CO2, H2CO, CH4, NO, N2O, NH3, SO2, CH3OH, acetylene, ethylene, ethane and total hydrocarbons, most of which are not regulated nor measured by current emissions control programs, can be accurately monitored with a single instrument. An FTIR spectrometer is used for the analysis of a constant flow of sample gas from the tail-pipe into a stainless-steel cylindrical cell of constant volume.(1) The cell is heated to 185 °C to avoid condensation, the pressure is kept constant and a multi-pass optical arrangement(2)is used to transmit the modulated infrared beam several times to improve the sensitivity. The total flow from the exhaust used for calculating the emission can be continuously determined from the differential pressure measurements from a "Pitot" tube calibrated against a hot-wire devise. This simple methodology is proposed for performing state-of-the-art evaluations on the emission behavior of new technologies, reformulated fuels and emission control devices. The results presented here were performed on a dynamometer running FTP-75 and driving cycles typical for Mexico City.(3,4) References 1. Grutter M. "Multi-Gas Analysis using FTIR Spectroscopy over Mexico City." Atmosfera 16, 1-16 (2003). 2. White J.U. "Long optical paths of large aperture. J. Opt. Soc. Am., 32, 285-288 (1942). 3. Santiago Cruz L. and P.I. Rincón. "Instrumentation of the Emission Control Laboratory at the Engineering School of the National Autonomous University of Mexico." Instrumentation and Development 4, 19-24, (2000). 4. González Oropeza R. and A. Galván Zacarías. "Desarrollo de ciclos de manejo característicos de la Ciudad de México." Memorias

  18. Measurement of the Shape of the Optical-IR Spectrum of Prompt Emission from Gamma-Ray Bursts

    Science.gov (United States)

    Grossan, Bruce; Kistaubayev, M.; Smoot, G.; Scherr, L.

    2017-06-01

    While the afterglow phase of gamma-ray bursts (GRBs) has been extensively measured, detections of prompt emission (i.e. during bright X-gamma emission) are more limited. Some prompt optical measurements are regularly made, but these are typically in a single wide band, with limited time resolution, and no measurement of spectral shape. Some models predict a synchrotron self-absorption spectral break somewhere in the IR-optical region. Measurement of the absorption frequency would give extensive information on each burst, including the electron Lorentz factor, the radius of emission, and more (Shen & Zhang 2008). Thus far the best prompt observations have been explained invoking a variety of models, but often with a non-unique interpretation. To understand this apparently heterogeneous behavior, and to reduce the number of possible models, it is critical to add data on the optical - IR spectral shape.Long GRB prompt X-gamma emission typically lasts ~40-80 s. The Swift BAT instrument rapidly measures GRB positions to within a few arc minutes and communicates them via the internet within a few seconds. We have measured the time for a fast-moving D=700 mm telescope to point and settle to be less than 9 s anywhere on the observable sky. Therefore, the majority of prompt optical-IR emission can be measured responding to BAT positions with this telescope. In this presentation, we describe our observing and science programs, and give our design for the Burst Simultaneous Three-channel Instrument (BSTI), which uses dichroics to send eparate bands to 3 cameras. Two EMCCD cameras, give high-time resolution in B and V; a third camera with a HgCdTe sensor covers H band, allowing us to study extinguished bursts. For a total exposure time of 10 s, we find a 5 sigma sensitivity of 21.3 and 20.3 mag in B and R for 1" seeing and Kitt Peak sky brightness, much fainter than typical previous prompt detections. We estimate 5 sigma H-band sensitivity for an IR optimized telescope to be

  19. X-ray fluorescence imaging with polycapillary X-ray optics

    International Nuclear Information System (INIS)

    Yonehara, Tasuku; Yamaguchi, Makoto; Tsuji, Kouichi

    2010-01-01

    X-ray fluorescence spectrometry imaging is a powerful tool to provide information about the chemical composition and elemental distribution of a specimen. X-ray fluorescence spectrometry images were conventionally obtained by using a μ-X-ray fluorescence spectrometry spectrometer, which requires scanning a sample. Faster X-ray fluorescence spectrometry imaging would be achieved by eliminating the process of sample scanning. Thus, we developed an X-ray fluorescence spectrometry imaging instrument without sample scanning by using polycapillary X-ray optics, which had energy filter characteristics caused by the energy dependence of the total reflection phenomenon. In the present paper, we show that two independent straight polycapillary X-ray optics could be used as an energy filter of X-rays for X-ray fluorescence. Only low energy X-rays were detected when the angle between the two optical axes was increased slightly. Energy-selective X-ray fluorescence spectrometry images with projection mode were taken by using an X-ray CCD camera equipped with two polycapillary optics. It was shown that Fe Kα (6.40 keV) and Cu Kα (8.04 keV) could be discriminated for Fe and Cu foils.

  20. Detection of elusive radio and optical emission from cosmic-ray showers in the 1960s

    International Nuclear Information System (INIS)

    Fegan, David J.

    2012-01-01

    During the 1960s, a small but vibrant community of cosmic ray physicists, pioneered novel optical methods of detecting extensive air showers (EAS) in the Earth's atmosphere with the prime objective of searching for point sources of energetic cosmic γ-rays. Throughout that decade, progress was extremely slow. Attempts to use the emission of optical Cherenkov radiation from showers as a basis for TeV gamma-ray astronomy proved difficult and problematical, given the rather primitive light-collecting systems in use at the time, coupled with a practical inability to reject the overwhelming background arising from hadronic showers. Simultaneously, a number of groups experimented with passive detection of radio emission from EAS as a possible cheap, simple, stand-alone method to detect and characterise showers of energy greater than 10 16 eV. By the end of the decade, it was shown that the radio emission was quite highly beamed and hence the effective collection area for detection of high energy showers was quite limited, diminishing the effectiveness of the radio signature as a stand-alone shower detection channel. By the early 1970s much of the early optimism for both the optical and radio techniques was beginning to dissipate, greatly reducing research activity. However, following a long hiatus both avenues were in time revived, the optical in the early 1980s and the radio in the early 2000s. With the advent of digital logic hardware, powerful low-cost computing, the ability to perform Monte Carlo simulations and above all, greatly improved funding, rapid progress became possible. In time this work proved to be fundamental to both High Energy γ-ray Astronomy and Neutrino Astrophysics. Here, that first decade of experimental investigation in both fields is reviewed.

  1. Detection of elusive radio and optical emission from cosmic-ray showers in the 1960s

    Energy Technology Data Exchange (ETDEWEB)

    Fegan, David J., E-mail: david.fegan@ucd.ie [School of Physics, University College Dublin, Dublin 4 (Ireland)

    2012-01-11

    During the 1960s, a small but vibrant community of cosmic ray physicists, pioneered novel optical methods of detecting extensive air showers (EAS) in the Earth's atmosphere with the prime objective of searching for point sources of energetic cosmic {gamma}-rays. Throughout that decade, progress was extremely slow. Attempts to use the emission of optical Cherenkov radiation from showers as a basis for TeV gamma-ray astronomy proved difficult and problematical, given the rather primitive light-collecting systems in use at the time, coupled with a practical inability to reject the overwhelming background arising from hadronic showers. Simultaneously, a number of groups experimented with passive detection of radio emission from EAS as a possible cheap, simple, stand-alone method to detect and characterise showers of energy greater than 10{sup 16} eV. By the end of the decade, it was shown that the radio emission was quite highly beamed and hence the effective collection area for detection of high energy showers was quite limited, diminishing the effectiveness of the radio signature as a stand-alone shower detection channel. By the early 1970s much of the early optimism for both the optical and radio techniques was beginning to dissipate, greatly reducing research activity. However, following a long hiatus both avenues were in time revived, the optical in the early 1980s and the radio in the early 2000s. With the advent of digital logic hardware, powerful low-cost computing, the ability to perform Monte Carlo simulations and above all, greatly improved funding, rapid progress became possible. In time this work proved to be fundamental to both High Energy {gamma}-ray Astronomy and Neutrino Astrophysics. Here, that first decade of experimental investigation in both fields is reviewed.

  2. Efficient high-resolution X-ray emission spectrometry using synchrotron radiation

    International Nuclear Information System (INIS)

    Unterumsberger, Rainer

    2015-01-01

    The aim of the present work is to get access to high-resolution X-Ray Emission Spectrometry (XES) at nanoscaled materials, consisting of light elements and transition metals, by the increase of the sensitivity of a Wavelength-Dispersive Spectrometer (WDS) in the soft X-Ray range. The increase of the sensitivity was achieved by a refocusing of the incident radiation. With the increased sensitivity of the WDS, it was possible to determine the chemical species of different, nominal 100 nm thin titanium oxides. The combination of the refocusing optic and calibrated spectrometer enabled the detection and deconvolution of the L-fluorescence radiation of these nanoscaled titanium oxides. Due to the calibration of the spectrometer, a reliable determination of the transition probabilities of the titanium La- and Ll-fluorescence lines as a function of the chemical state is possible. To the best of my knowledge, the determination of the transition probabilities as a function of the chemical state in the soft X-Ray range has not been investigated yet. The quality of the refocusing was characterized using different diagnostic tools. Vertical full width at half maximum (FWHM) values of the focused beam between 10 μm to 20 μm and horizontal FWHM values between 12 μm and 25 μm could be achieved over an energy range of 180 eV to 1310 eV. Using calibrated photodiodes, it was possible to determine the absolute transmission of the used single bounce monocapillary as well as to monitor the absolute photon flux. By means of the refocusing, it was possible to increase the photon flux by a factor of 4.9 experimentally. The increase of the photon flux enables the analysis of nanoscaled materials with the used spectrometer. This could be shown based on the determination of the lower limit of detection of boron Ka and titanium La. In both cases, the lower limit of detection of 0.4 nm equivalent layer thickness was achieved (about 1.10 -7 g/cm 2 to 2.10 -7 g/cm 2 or 3.10 15 atoms/cm 2 to

  3. A promising new mechanism of ionizing radiation detection for positron emission tomography: Modulation of optical properties

    OpenAIRE

    Tao, Li; Daghighian, Henry M.; Levin, Craig S.

    2016-01-01

    Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the other hand, modulation mechanisms of the optical properties of a material exploited in the optical telecommunications industry can be orders of magnitude faster. In this paper we...

  4. Liquid sample introduction in inductively coupled plasma atomic emission and mass spectrometry — Critical review

    International Nuclear Information System (INIS)

    Bings, N.H.; Orlandini von Niessen, J.O.; Schaper, J.N.

    2014-01-01

    Inductively coupled plasma optical emission spectroscopy (ICP-OES) and mass spectrometry (ICP-MS) can be considered as the most important tools in inorganic analytical chemistry. Huge progress has been made since the first analytical applications of the ICP. More stable RF generators, improved spectrometers and detection systems were designed along with the achievements gained from advanced microelectronics, leading to overall greatly improved analytical performance of such instruments. In contrast, for the vast majority of cases liquid sample introduction is still based on the pneumatic principle as described in the late 19th century. High flow pneumatic nebulizers typically demand the use of spray chambers as “aerosol filters” in order to match the prerequisites of an ICP. By this, only a small fraction of the nebulized sample actually contributes to the measured signal. Hence, the development of micronebulizers was brought forward. Those systems produce fine aerosols at low sample uptake rates, but they are even more prone for blocking or clogging than conventional systems in the case of solutions containing a significant amount of total dissolved solids (TDS). Despite the high number of publications devoted to liquid sample introduction, it is still considered the Achilles' heel of atomic spectrometry and it is well accepted, that the technology used for liquid sample introduction is still far from ideal, even when applying state-of-the-art systems. Therefore, this review is devoted to offer an update on developments in the field liquid sample introduction that had been reported until the year 2013. The most recent and noteworthy contributions to this field are discussed, trends are highlighted and future directions are outlined. The first part of this review provides a brief overview on theoretical considerations regarding conventional pneumatic nebulization, the fundamentals on aerosol generation and discusses characteristics of aerosols ideally

  5. Liquid sample introduction in inductively coupled plasma atomic emission and mass spectrometry — Critical review

    Energy Technology Data Exchange (ETDEWEB)

    Bings, N.H., E-mail: bings@uni-mainz.de; Orlandini von Niessen, J.O.; Schaper, J.N.

    2014-10-01

    Inductively coupled plasma optical emission spectroscopy (ICP-OES) and mass spectrometry (ICP-MS) can be considered as the most important tools in inorganic analytical chemistry. Huge progress has been made since the first analytical applications of the ICP. More stable RF generators, improved spectrometers and detection systems were designed along with the achievements gained from advanced microelectronics, leading to overall greatly improved analytical performance of such instruments. In contrast, for the vast majority of cases liquid sample introduction is still based on the pneumatic principle as described in the late 19th century. High flow pneumatic nebulizers typically demand the use of spray chambers as “aerosol filters” in order to match the prerequisites of an ICP. By this, only a small fraction of the nebulized sample actually contributes to the measured signal. Hence, the development of micronebulizers was brought forward. Those systems produce fine aerosols at low sample uptake rates, but they are even more prone for blocking or clogging than conventional systems in the case of solutions containing a significant amount of total dissolved solids (TDS). Despite the high number of publications devoted to liquid sample introduction, it is still considered the Achilles' heel of atomic spectrometry and it is well accepted, that the technology used for liquid sample introduction is still far from ideal, even when applying state-of-the-art systems. Therefore, this review is devoted to offer an update on developments in the field liquid sample introduction that had been reported until the year 2013. The most recent and noteworthy contributions to this field are discussed, trends are highlighted and future directions are outlined. The first part of this review provides a brief overview on theoretical considerations regarding conventional pneumatic nebulization, the fundamentals on aerosol generation and discusses characteristics of aerosols ideally

  6. Application of Laser Mass Spectrometry to Art and Archaeology

    Science.gov (United States)

    Gulian, Lase Lisa E.; Callahan, Michael P.; Muliadi, Sarah; Owens, Shawn; McGovern, Patrick E.; Schmidt, Catherine M.; Trentelman, Karen A.; deVries, Mattanjah S.

    2011-01-01

    REMPI laser mass spectrometry is a combination of resonance enhanced multiphoton ionization spectroscopy and time of flight mass spectrometry, This technique enables the collection of mass specific optical spectra as well as of optically selected mass spectra. Analytes are jet-cooled by entrainment in a molecular beam, and this low temperature gas phase analysis has the benefit of excellent vibronic resolution. Utilizing this method, mass spectrometric analysis of historically relevant samples can be simplified and improved; Optical selection of targets eliminates the need for chromatography while knowledge of a target's gas phase spectroscopy allows for facile differentiation of molecules that are in the aqueous phase considered spectroscopically indistinguishable. These two factors allow smaller sample sizes than commercial MS instruments, which in turn will require less damage to objects of antiquity. We have explored methods to optimize REMPI laser mass spectrometry as an analytical tool to archaeology using theobromine and caffeine as molecular markers in Mesoamerican pottery, and are expanding this approach to the field of art to examine laccaic acid in shellacs.

  7. Comparison endpoint study of process plasma and secondary electron beam exciter optical emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stephan Thamban, P. L.; Yun, Stuart; Padron-Wells, Gabriel; Hosch, Jimmy W.; Goeckner, Matthew J. [Department of Mechanical Engineering, University of Texas at Dallas, 800W Campbell Road, Richardson, Texas 75080 (United States); Department of Electrical Engineering, University of Texas at Dallas, 800W Campbell Road, Richardson, Texas 75080 (United States); Verity Instruments, Inc., 2901 Eisenhower Street, Carrollton, Texas 75007 (United States); Department of Mathematical Sciences, University of Texas at Dallas, 800 W Campbell Road, Richardson, Texas 75080 (United States)

    2012-11-15

    Traditionally process plasmas are often studied and monitored by optical emission spectroscopy. Here, the authors compare experimental measurements from a secondary electron beam excitation and direct process plasma excitation to discuss and illustrate its distinctiveness in the study of process plasmas. They present results that show excitations of etch process effluents in a SF{sub 6} discharge and endpoint detection capabilities in dark plasma process conditions. In SF{sub 6} discharges, a band around 300 nm, not visible in process emission, is observed and it can serve as a good indicator of etch product emission during polysilicon etches. Based on prior work reported in literature the authors believe this band is due to SiF{sub 4} gas phase species.

  8. Interplay of coupling and superradiant emission in the optical response of a double quantum dot

    Science.gov (United States)

    Sitek, Anna; Machnikowski, Paweł

    2009-09-01

    We study theoretically the optical response of a double quantum dot structure to an ultrafast optical excitation. We show that the interplay of a specific type of coupling between the dots and their collective interaction with the radiative environment leads to very characteristic features in the time-resolved luminescence as well as in the absorption spectrum of the system. For a sufficiently strong coupling, these effects survive even if the transition energy mismatch between the two dots exceeds by far the emission linewidth.

  9. [Measurement of plasma parameters in slot microplasma by optical emission spectrum].

    Science.gov (United States)

    Dong, Li-Fang; Lü, Ying-Hui; Liu, Wei-Yuan; Yue, Han; Lu, Ning; Li, Xin-Chun

    2010-12-01

    Slot microplasma was generated in argon and air mixture by using dielectric barrier discharge device with two parallel water electrodes. The molecular vibrational temperature, molecular rotational temperature and average electron energy of the slot plasma were studied by optical emission spectrum. The molecular vibrational temperature was calculated using the second positive system of nitrogen molecules ( C3 pi(u) --> B3 pi(g)). The molecular rotational temperature was calculated using the first negative system of nitrogen molecular ions ( B 2sigma(u)+ --> X sigma(g)+). The relative intensities of the first negative system of nitrogen molecular ions (391.4 nm) and nitrogen molecules in the excitation level (337.1 nm) emission spectrum line were measured for studying the variations of electron energy. It was found that the molecular vibrational temperature, molecular rotational temperature and average electron energy decrease with gas pressure increasing.

  10. Phototype design and testing of two fiber-optic spectrochemical emission sensors

    International Nuclear Information System (INIS)

    Olsen, K.B.; Nelson, D.A.; Griffin, J.W.; Matson, B.S.; Eschbach, P.A.

    1988-09-01

    A unique radio frequency-induced helium plasma (RFIHP) sensor and a spark discharge (SD) sensor were designed, and prototype units were developed and tested. Both sensors use an atomic excitation source coupled to a fiber-optic cable and optical spectrometer to monitor in situ the emission intensity of selected elements of interest in the ambient air. Potential applications include vadose zone monitoring of volatile species. The RFIHP sensor was designed to measure the total chlorine concentration from carbon tetrachloride (and other volatile chlorinated hydrocarbons), and the SD sensor was designed to measure in situ concentrations of chlorine-containing compounds. The results of this research demonstrate proof of concept of the theory, but suggest further refinements are necessary to achieve detection sensitivities sufficiently low to be useful for monitoring concentrations of selected elements in vadose zone air. 9 refs., 10 figs

  11. Effect of aromatic compounds on radiation resistance of polymers studied by optical emission

    International Nuclear Information System (INIS)

    Kawanishi, Shunichi; Hagiwara, Miyuki

    1987-10-01

    To clarify the effects of condensed bromoacenaphthylene (con-BACN) as a newly developed flame retardant on the radiation resistance of ethylene-propylene-diene-terpolymer (EPDM), optical emission behavior of aromatic compounds, acenaphthylene and acenaphthene as model compound of con-BACN was studied. The energy absorbed in polymer matrix is transferred to the aromatic molecules very fast within 1 ns, and introduces excited states of aromatic compound. The fluorescence from naphthalene units of the additives with peak at 337 and 350 nm (named AT emission band) was observed in EPDM containing acenaphthene or acenaphthylene. When aromatic peroxide was used as a crosslinking agent, another emission band (Xn band) was observed at 400 nm. It was found that these emission bands play a role in trapping sites in which a part of radiation energy release in the form of fluorescence. The energy level of the excited state was correlated to the radiation stability measured with coloration and oxidation reaction of the polymer. Furthermore, acenaphthylene having a reactive vinyl bond forms excimer emission band Ex whose level is lower than those of AT and Xn bands, and therefore, enhances radiation stability of matrix polymer by giving effective routes for energy release. (author)

  12. Novel Electro-Optical Coupling Technique for Magnetic Resonance-Compatible Positron Emission Tomography Detectors

    Directory of Open Access Journals (Sweden)

    Peter D. Olcott

    2009-03-01

    Full Text Available A new magnetic resonance imaging (MRI-compatible positron emission tomography (PET detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.

  13. Novel electro-optical coupling technique for magnetic resonance-compatible positron emission tomography detectors.

    Science.gov (United States)

    Olcott, Peter D; Peng, Hao; Levin, Craig S

    2009-01-01

    A new magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL) diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.

  14. Comparison of inductively coupled plasma mass spectrometry with inductively coupled plasma atomic emission spectrometry and instrumental neutron activation analysis for the determination of rare earth elements in Greek bauxites

    International Nuclear Information System (INIS)

    Ochsenkuehn-Petropoulou, Maria; Luck, Joachim

    1991-01-01

    Fore the determination of rare earth elements (REE) in bauxitic materials the techniques of inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma atomic emission spectrometry (ICP-AES) and instrumental neutron activation analysis (INAA) were compared. In the NIST (National Institute of Standards and Technology) bauxites SRM 697 Dominican, and SRM 69 b Arkansas, the concentration of some REEs were determined. With the reference bauxite BX-N of the ARNT (Association Nationale de la Recherche Technique) the precision and accuracy of ICP-AES for the determination of REEs in bauxites was tested. Furthermore, Greek bauxites of the Parnassos-Giona area were investigated. In a comparison of the three methods it was possible to calculate from the data series the precision of each method, which showed that the tendency found in the deviations for the different REEs is in accordance with published values. Also the limits of detection for REEs in bauxites were calculated and found to be in the same range as those in the literature. (author)

  15. X-ray spectrometry with synchrotron radiation; Roentgenspektrometrie mit Synchrotronstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Matthias [Physikalisch-Technische Bundesanstalt (PTB), Berlin (Germany). Arbeitsgruppe ' Roentgen- und IR-Spektrometrie' ; Gerlach, Martin; Holfelder, Ina; Hoenicke, Philipp; Lubeck, Janin; Nutsch, Andreas; Pollakowski, Beatrix; Streeck, Cornelia; Unterumsberger, Rainer; Weser, Jan; Beckhoff, Burkhard

    2014-12-15

    The X-ray spectrometry of the PTB at the BESSY II storage ring with radiation in the range from 78 eV to 10.5 keV is described. After a description of the instrumentation development reference-sample free X-ray fluorescence analysis, the determination of fundamental atomic parameters, X-ray fluorescence analysis under glance-angle incidence, highly-resolving absorption spectrometry, and emission spectrometry are considered. Finally liquid cells and in-situ measurement techniques are described. (HSI)

  16. Understanding the effects of potassium ferricyanide on lead hydride formation in tetrahydroborate system and its application for determination of lead in milk using hydride generation inductively coupled plasma optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Biyang, E-mail: dengby16@163.com; Xu, Xiangshu; Xiao, Yan; Zhu, Pingchuan; Wang, Yingzi

    2015-01-01

    Highlights: • Proposed a novel explanation for plumbane generation. • Expounded the role of K{sub 3}Fe(CN){sub 6} in plumbane generation. • Clarified the controversial aspects in the mechanism of K{sub 3}Fe(CN){sub 6} enhancement. • Used X-ray diffractometry to analyze the intermediates. • Developed a method to analyze lead in milk using K{sub 3}Fe(CN){sub 6} and K{sub 4}Fe(CN){sub 6} as new additives. - Absract: To understand the formation of plumbane in the Pb{sup II}-NaBH{sub 4}-K{sub 3}Fe(CN){sub 6} system, the intermediate products produced in the reaction of lead(II) and NaBH{sub 4} in the presence of K{sub 3}Fe(CN){sub 6} were studied. The produced plumbane and elemental lead were measured through continuous flow hydride generation (HG)-inductively coupled plasma optical emission spectrometry (ICP OES) and X-ray diffraction spectrometry techniques, respectively. Based on the experimental results, the explanations can be depicted in the following steps: (1) plumbane and black lead sediment (black Pb) are formed in the reaction of lead(II) and NaBH{sub 4}; (2) the black Pb is oxidized by K{sub 3}Fe(CN){sub 6} to form Pb{sub 2}[Fe(CN){sub 6}], which further reacts with NaBH{sub 4} to form more plumbane and black Pb; and (3) another round starts in which the produced black Pb from the step 2 is then oxidized continuously by K{sub 3}Fe(CN){sub 6} to form more Pb{sub 2}[Fe(CN){sub 6}] complex, which would produce more plumbane. In short, the black Pb and Pb{sub 2}[Fe(CN){sub 6}] complex are the key intermediate products for the formation of plumbane in the Pb{sup II}-NaBH{sub 4}-K{sub 3}Fe(CN){sub 6} system. Based on the enhancement effect of potassium ferricyanide and potassium ferrocyanide, a method was developed to analyze lead in milk with HG-ICP OES technique. The detection limit of the method was observed as 0.081 μg L{sup −1}. The linearity range of lead was found between 0.3 and 50,000 μg L{sup −1} with correlation coefficient of 0

  17. Time resolved optical emission spectroscopy of cross-beam pulsed laser ablation on graphite targets

    International Nuclear Information System (INIS)

    Sangines, R.; Sanchez Ake, C.; Sobral, H.; Villagran-Muniz, M.

    2007-01-01

    Cross-beam pulsed laser ablation with two delayed lasers is performed on two perpendicular graphite targets. The time delay between lasers is varied by up to 5 μs, and physical changes on the second plasma, due to the interaction with the first generated one, are determined by time resolved optical emission spectroscopy

  18. Optical emission and mass spectroscopy of plasma processes in reactive DC pulsed magnetron sputtering of aluminium oxide

    Czech Academy of Sciences Publication Activity Database

    Novotný, Michal; Bulíř, Jiří; Pokorný, Petr; Bočan, Jiří; Fitl, Přemysl; Lančok, Ján; Musil, Jindřich

    2010-01-01

    Roč. 12, č. 3 (2010), 697-700 ISSN 1454-4164 R&D Projects: GA AV ČR IAA100100718; GA AV ČR KAN400100653; GA ČR GP202/09/P324 Institutional research plan: CEZ:AV0Z10100522 Keywords : reactive magnetron sputtering * alumina * plasma spectroscopy * mass spectroscopy * optical emission spectroscopy Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.412, year: 2010

  19. Optical Characterization of Doped Thermoplastic and Thermosetting Polymer-Optical-Fibers

    Directory of Open Access Journals (Sweden)

    Igor Ayesta

    2017-03-01

    Full Text Available The emission properties of a graded-index thermoplastic polymer optical fiber and a step-index thermosetting one, both doped with rhodamine 6G, have been studied. The work includes a detailed analysis of the amplified spontaneous emission together with a study of the optical gains and losses of the fibers. The photostability of the emission of both types of fibers has also been investigated. Comparisons between the results of both doped polymer optical fibers are presented and discussed.

  20. Effects of airflow on odorants' emissions in a model pig house — A laboratory study using Proton-Transfer-Reaction Mass Spectrometry (PTR-MS)

    International Nuclear Information System (INIS)

    Saha, Chayan Kumer; Feilberg, Anders; Zhang, Guoqiang; Adamsen, Anders Peter S.

    2011-01-01

    Identification of different factors that affect emissions of gasses, including volatile organic compounds (VOCs) is necessary to develop emission abatement technology. The objectives of this research were to quantify and study temporal variation of gas emissions from a model pig house under varying ventilation rates. The used model was a 1:12.5 scale of a section of a commercial finishing pig house. The VOC concentrations at inlet, outlet, and slurry pit of the model space were measured using Proton-Transfer-Reaction Mass Spectrometry (PTR-MS). PTR-MS can measure the temporal variations of odor compounds' emission from the slurry pit in real time. The emissions of H 2 S and 14 VOCs were lower compared to real pig buildings except for ammonia, which indicated possible other sources of those compounds than the slurry in the slurry pit. The ventilation rate affected significantly on ammonia and trimethylamine emission (p 2 S) emission was independent of the ventilation rate. VFAs' emission dependency on ventilation rate increased with the increase of carbon chain. Phenols, indoles and ketones showed the positive correlation with ventilation rate to some extent. Generally, compounds with high solubility (low Henry's constant) showed stronger correlation with ventilation rates than the compounds with high Henry's constant.

  1. Determination of rare earth elements by liquid chromatography/inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Yoshida, K.; Haraguchi, H.

    1984-01-01

    Inductively coupled plasma atomic emission spectrometry (ICP-AES) interfaced with high-performance liquid chromatography (HPLC) has been applied to the determination of rare earth elements. ICP-AES was used as an element-selective detector for HPLC. The separation of rare earth elements with HPLC helped to avoid erroneous analytical results due to spectral interferences. Fifteen rare earth elements (Y and 14 lanthanides) were determined selectively with the HPLC/ICP-AES system using a concentration gradient method. The detection limits with the present HPLC/ICP-AES system were about 0.001-0.3 μg/mL with a 100-μL sample injection. The calibration curves obtained by the peak height measurements showed linear relationships in the concentration range below 500 μg/mL for all rare earth elements. A USGS rock standard sample, rare earth ores, and high-purity lanthanide reagents (>99.9%) were successfully analyzed without spectral interferences

  2. The interaction with the lower ionosphere of electromagnetic pulses from lightning: Excitation of optical emissions

    Science.gov (United States)

    Taranenko, Y. N.; Inan, U. S.; Bell, T. F.

    1993-01-01

    A self consistent and fully kinetic simulation of the interaction of lightning radiated electromagnetic (EM) pulses with the nighttime lower ionosphere indicates that optical emissions observable with conventional instruments would be excited. For example, emissions of the 1st and 2nd positive bands of N2 occur at rates reaching 7 x 10(exp 7) and 10(exp 7) cu cm/s respectively at 92 km altitude for a lightning discharge with an electric field E(sub 100) = 20 V/m (normalized to a 100 km distance). The maximum height integrated intensities of these emissions are 4 x 10(exp 7) and 6 x 10(exp 6) R respectively, lasting for approx. 50 micrometers.

  3. Optical emission spectroscopy during fabrication of indium-tin-oxynitride films by RF-sputtering

    International Nuclear Information System (INIS)

    Koufaki, M.; Sifakis, M.; Iliopoulos, E.; Pelekanos, N.; Modreanu, M.; Cimalla, V.; Ecke, G.; Aperathitis, E.

    2006-01-01

    Indium-tin-oxide (ITO) and indium-tin-oxynitride (ITON) films have been deposited on glass by rf-sputtering from an ITO target, using Ar plasma and N 2 plasma, respectively, and different rf-power. Optical emission spectroscopy (OES) was employed to identify the species present in the plasma and to correlate them with the properties of the ITO and ITON thin films. Emission lines of ionic In could only be detected in N 2 plasma, whereas in the Ar plasma additional lines corresponding to atomic In and InO, were detected. The deposition rate of thin films was correlated with the In species, rather than the nitrogen species, emission intensity in the plasma. The higher resistivity and lower carrier concentration of the ITON films, as compared to the respective properties of the ITO films, were attributed to the incorporation of nitrogen, instead of oxygen, in the ITON structure

  4. Improving the quantitative accuracy of optical-emission computed tomography by incorporating an attenuation correction: application to HIF1 imaging

    Science.gov (United States)

    Kim, E.; Bowsher, J.; Thomas, A. S.; Sakhalkar, H.; Dewhirst, M.; Oldham, M.

    2008-10-01

    Optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT) are new techniques for imaging the 3D structure and function (including gene expression) of whole unsectioned tissue samples. This work presents a method of improving the quantitative accuracy of optical-ECT by correcting for the 'self'-attenuation of photons emitted within the sample. The correction is analogous to a method commonly applied in single-photon-emission computed tomography reconstruction. The performance of the correction method was investigated by application to a transparent cylindrical gelatin phantom, containing a known distribution of attenuation (a central ink-doped gelatine core) and a known distribution of fluorescing fibres. Attenuation corrected and uncorrected optical-ECT images were reconstructed on the phantom to enable an evaluation of the effectiveness of the correction. Significant attenuation artefacts were observed in the uncorrected images where the central fibre appeared ~24% less intense due to greater attenuation from the surrounding ink-doped gelatin. This artefact was almost completely removed in the attenuation-corrected image, where the central fibre was within ~4% of the others. The successful phantom test enabled application of attenuation correction to optical-ECT images of an unsectioned human breast xenograft tumour grown subcutaneously on the hind leg of a nude mouse. This tumour cell line had been genetically labelled (pre-implantation) with fluorescent reporter genes such that all viable tumour cells expressed constitutive red fluorescent protein and hypoxia-inducible factor 1 transcription-produced green fluorescent protein. In addition to the fluorescent reporter labelling of gene expression, the tumour microvasculature was labelled by a light-absorbing vasculature contrast agent delivered in vivo by tail-vein injection. Optical-CT transmission images yielded high-resolution 3D images of the absorbing contrast agent, and

  5. Improving the quantitative accuracy of optical-emission computed tomography by incorporating an attenuation correction: application to HIF1 imaging

    International Nuclear Information System (INIS)

    Kim, E; Bowsher, J; Thomas, A S; Sakhalkar, H; Dewhirst, M; Oldham, M

    2008-01-01

    Optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT) are new techniques for imaging the 3D structure and function (including gene expression) of whole unsectioned tissue samples. This work presents a method of improving the quantitative accuracy of optical-ECT by correcting for the 'self'-attenuation of photons emitted within the sample. The correction is analogous to a method commonly applied in single-photon-emission computed tomography reconstruction. The performance of the correction method was investigated by application to a transparent cylindrical gelatin phantom, containing a known distribution of attenuation (a central ink-doped gelatine core) and a known distribution of fluorescing fibres. Attenuation corrected and uncorrected optical-ECT images were reconstructed on the phantom to enable an evaluation of the effectiveness of the correction. Significant attenuation artefacts were observed in the uncorrected images where the central fibre appeared ∼24% less intense due to greater attenuation from the surrounding ink-doped gelatin. This artefact was almost completely removed in the attenuation-corrected image, where the central fibre was within ∼4% of the others. The successful phantom test enabled application of attenuation correction to optical-ECT images of an unsectioned human breast xenograft tumour grown subcutaneously on the hind leg of a nude mouse. This tumour cell line had been genetically labelled (pre-implantation) with fluorescent reporter genes such that all viable tumour cells expressed constitutive red fluorescent protein and hypoxia-inducible factor 1 transcription-produced green fluorescent protein. In addition to the fluorescent reporter labelling of gene expression, the tumour microvasculature was labelled by a light-absorbing vasculature contrast agent delivered in vivo by tail-vein injection. Optical-CT transmission images yielded high-resolution 3D images of the absorbing contrast agent

  6. Enhanced broadband upconversion emission and 23 dB optical gain at 780 nm in Tm3+/Nd3+ codoped optical fiber

    International Nuclear Information System (INIS)

    Fan, Weiwei; Chen, Shuyue; Htein, Lin; Han, Won-Taek

    2015-01-01

    Maximum gain of 23 dB at 780 nm and a broadband optical gain with full width at half maximum (FWHM) of 88 nm (761–849 nm) were obtained from the Tm 3+ /Nd 3+ codoped fiber upon pumping at 1550 nm. The enhancement of the upconversion emission stretching from 730 to 970 nm was observed in the Tm 3+ /Nd 3+ codoped fiber due to the energy transfer from Tm 3+ to Nd 3+ ions. - Highlights: • We fabricated the Tm 3+ /Nd 3+ codoped silica based fiber. • The broadband upconversion emission was observed with 1550 nm pumping. • Maximum gain of 23 dB was observed at 780 nm from the Tm 3+ /Nd 3+ codoped fiber. • The gain bandwidth of the upconversion emission was largely increased due to energy transfer process

  7. A new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties

    Science.gov (United States)

    Tao, Li; Daghighian, Henry M.; Levin, Craig S.

    2016-10-01

    Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) annihilation photon pair coincidence time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit of around 100 ps. On the other hand, modulation mechanisms of a material's optical properties as exploited in the optical telecommunications industry can be orders of magnitude faster. In this paper we borrow from the concept of optics pump-probe measurement to study whether ionizing radiation can also produce fast modulations of optical properties, which can be utilized as a novel method for radiation detection. We show that a refractive index modulation of approximately 5x10-6 is induced by interactions in a cadmium telluride (CdTe) crystal from a 511 keV photon source. Furthermore, using additional radionuclide sources, we show that the amplitude of the optical modulation signal varies linearly with both the radiation source flux rate and average photon energy.

  8. Speciation analysis of organomercurial compounds in Fish Tissue by capillary gas chromatography coupled to microwave-induced plasma atomic emission detection

    Directory of Open Access Journals (Sweden)

    Dorfe Díaz

    Full Text Available This paper describes a novel approach for analysis of mercury speciation in fish using gas chromatography coupled with microwave-induced plasma optical emission spectrometry (GC-MIP-OES in surfatron resonant cavity. Sample treatment was based on quantitative leaching of mercury species from fish tissue with ultrasound-assisted acid-toluene extraction. The extracted mercury species analyzed with GC-MIP-OES attained detection limits of 5 and 9 pg for methylmercury (MeHg and ethylmercury (EtHg, respectively. A complete chromatogram could be completed in 1.5 min. MeHg values obtained with GC-MIP-OES were matched with organic mercury values obtained with selective reduction cold vapour- atomic absorption spectrometry (CV-AAS.

  9. THE RELATION OF OPTICAL/ULTRAVIOLET AND X-RAY EMISSION IN LOW-LUMINOSITY ACTIVE GALACTIC NUCLEI

    International Nuclear Information System (INIS)

    Xu Yadi

    2011-01-01

    We study the relation of optical/UV and X-ray emission in the low luminosity active galactic nuclei (LLAGNs), using a sample of 49 sources including 28 local Seyfert galaxies and 21 low-ionization nuclear emission-line regions with optical/UV spectral luminosity at wavelength λ = 2500 A, 23.0 ≤ log L ν(2500A) (erg s -1 Hz -1 ) ≤ 27.7, and X-ray spectral luminosity at 2 keV, 20.5 ≤ log L ν(2keV) ≤ 25.3. Strong correlations are found between the X-ray luminosity and the optical/UV-to-X-ray index, α ox , with the optical/UV luminosity, with slopes very similar to the findings for the luminous AGNs in previous works. The correlation between α ox and L ν(2keV) is very weak, as is that found for the luminous AGNs in the majority of previous similar works. We also study the relation between α ox and the Eddington ratio L bol /L Edd for our sample and find a significant anti-correlation for the sources with L bol /L Edd ∼ -3 , which is opposite to the correlation between the two variables for the luminous AGNs. Using the advection-dominated accretion flow (ADAF) model, we roughly reproduce this anti-correlationship for the two variables for the LLAGNs. This result strongly supports the ADAF as a candidate for the accretion mode in LLAGNs.

  10. Multielemental Determination of As, Bi, Ge, Sb, and Sn in Agricultural Samples Using Hydride Generation Coupled to Microwave-Induced Plasma Optical Emission Spectrometry.

    Science.gov (United States)

    Machado, Raquel C; Amaral, Clarice D B; Nóbrega, Joaquim A; Araujo Nogueira, Ana Rita

    2017-06-14

    A microwave-induced plasma optical emission spectrometer with N 2 -based plasma was combined with a multimode sample introduction system (MSIS) for hydride generation (HG) and multielemental determination of As, Bi, Ge, Sb, and Sn in samples of forage, bovine liver, powdered milk, agricultural gypsum, rice, and mineral fertilizer, using a single condition of prereduction and reduction. The accuracy of the developed analytical method was evaluated using certified reference materials of water and mineral fertilizer, and recoveries ranged from 95 to 106%. Addition and recovery experiments were carried out, and the recoveries varied from 85 to 117% for all samples evaluated. The limits of detection for As, Bi, Ge, Sb, and Sn were 0.46, 0.09, 0.19, 0.46, and 5.2 μg/L, respectively, for liquid samples, and 0.18, 0.04, 0.08, 0.19, and 2.1 mg/kg, respectively, for solid samples. The method proposed offers a simple, fast, multielemental, and robust alternative for successful determination of all five analytes in agricultural samples with low operational cost without compromising analytical performance.

  11. Optically stimulated exoelectron emission processes in quartz: comparison of experiment and theory

    DEFF Research Database (Denmark)

    Pagonis, V.; Ankjærgaard, Christina; Murray, A.S.

    2009-01-01

    Recent experiments have demonstrated that it is possible to measure optically stimulated exoelectron emission (OSE) signals simultaneously with optically stimulated luminescence (OSL) from quartz samples. These experiments provide valuable information on the charge movement in quartz grains. Two...... data yield a value of χ1.2 eV for the work function of quartz. The experimental temperature dependence of the OSE signals is interpreted on the basis of a photo-thermostimulated (PTSEE) process involving the main OSL trap at 320 °C; this process takes place with a thermal assistance energy estimated...... at W(0.29±0.02) eV. Good quantitative agreement is obtained between theory and experiment by assuming a thermal broadening of the thermal depletion factor for the OSL traps, described by a Gaussian distribution of energies....

  12. Thallium and manganese complexes involved in the luminescence emission of potassium-bearing aluminosilicates

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Gonzalez, Miguel A., E-mail: miguel.gomez@mncn.csic.es [Museo Nacional de Ciencias Naturales, CSIC, Jose Gutierrez Abascal 2, Madrid E-28006 (Spain); Garcia-Guinea, Javier, E-mail: guinea@mncn.csic.es [Museo Nacional de Ciencias Naturales, CSIC, Jose Gutierrez Abascal 2, Madrid E-28006 (Spain); Garrido, Fernando, E-mail: fernando.garrido@mncn.csic.es [Museo Nacional de Ciencias Naturales, CSIC, Jose Gutierrez Abascal 2, Madrid E-28006 (Spain); Townsend, Peter D., E-mail: pdtownsend@gmail.com [School of Science and Technology, University of Sussex, Brighton BN1 9QH (United Kingdom); Marco, Jose-Francisco, E-mail: jfmarco@iqfr.csic.es [Instituto de Química-Física Rocasolano, CSIC, Calle Serrano 119, Madrid E-28006 (Spain)

    2015-03-15

    The luminescence emission at 285 nm in natural K-feldspar has been studied by Russian groups and associated with thallium ions in structural positions of K{sup +} sites as artificially thallium-doped feldspars display the same emission band. Here attention is focussed on spectra of CL emission bands centered near 285 and 560 nm from paragenetic adularia, moscovite and quartz micro-inclusions. With accesorial thallium they show clear resemblances to each other. Associated sedimentary and hydrothermal aluminosilicate samples collected from Guadalix (Madrid, Spain) were analyzed with a wide range of experimental techniques including Environmental Scanning Electron Microscopy (ESEM) with an attached X-Ray Energy-Dispersive Spectrometer (EDS) and a cathodoluminescence probe (CL) and Electron Probe Microanalysis (EPMA), X-Ray Fluorescence Spectrometry (XRF), Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES), Differential and Thermogravimetric Analyses (DTA-TG), radioluminescence (RL), Mössbauer spectroscopy and X-Ray Photoelectron Spectrometry (XPS). The luminescence emission bands at 285 and 560 nm seem to be associated with hydrous thallium–manganese complexes bonded to potassium-bearing aluminosilicates since various minerals such as K-feldspar, moscovite and quartz micro-inclusions display similar CL spectra, accesorial thallium and hydroxyl groups. The presence of iron introduces a brown color which is attributed to submicroscopic iron oxides detectable in the optical and chemical microanalysis, but this does not contribute to the luminescence emission. The XPS Mn 2p spectrum of the adularia sample at room temperature is composed of a spin–orbit doublet plus clear shake-up satellite structure ∼4 eV above the main photoemision lines and is consistent with Mn{sup 2+} in good agreement with the observed luminescence emission at 560 nm for aluminosilicates produced by a {sup 4}T1({sup 4}G)→{sup 6}A1({sup 6}S) transition in tetrahedrally

  13. Extractive sampling and optical remote sensing of F100 aircraft engine emissions.

    Science.gov (United States)

    Cowen, Kenneth; Goodwin, Bradley; Joseph, Darrell; Tefend, Matthew; Satola, Jan; Kagann, Robert; Hashmonay, Ram; Spicer, Chester; Holdren, Michael; Mayfield, Howard

    2009-05-01

    The Strategic Environmental Research and Development Program (SERDP) has initiated several programs to develop and evaluate techniques to characterize emissions from military aircraft to meet increasingly stringent regulatory requirements. This paper describes the results of a recent field study using extractive and optical remote sensing (ORS) techniques to measure emissions from six F-15 fighter aircraft. Testing was performed between November 14 and 16, 2006 on the trim-pad facility at Tyndall Air Force Base in Panama City, FL. Measurements were made on eight different F100 engines, and the engines were tested on-wing of in-use aircraft. A total of 39 test runs were performed at engine power levels that ranged from idle to military power. The approach adopted for these tests involved extractive sampling with collocated ORS measurements at a distance of approximately 20-25 nozzle diameters downstream of the engine exit plane. The emission indices calculated for carbon dioxide, carbon monoxide, nitric oxide, and several volatile organic compounds showed very good agreement when comparing the extractive and ORS sampling methods.

  14. Optical emission spectrographic analysis of thulium oxide for rare earth impurities

    International Nuclear Information System (INIS)

    Chandola, L.C.; Khanna, P.P.; Dixit, V.C.

    1988-01-01

    An optical emission spectrographic method has been developed for the analysis of high purity thulium oxide to determine rare earth elements Er, Yb, Lu and Y. A 1200 groove/mm grating blazed at 3300 A is used to record the spectrum on Kodak SA-1 photographic plates after the excitation of the graphite-sample (1:1) mixture in DC arc. The determination range is 0.008 per cent to 0.1 per cent and the relative standard deviation is 17.6 per cent. (author). 15 refs., 5 tables, 5 figs

  15. Multielement determination of rare earth elements by liquid chromatography/inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Sawatari, Hideyuki; Asano, Takaaki; Hu, Xincheng; Saizuka, Tomoo; Itoh, Akihide; Hirose, Akio; Haraguchi, Hiroki

    1995-01-01

    The rapid determination of rare earth elements (REEs) has been investigated by an on-line system of high performance liquid chromatography/multichannel inductively coupled plasma atomic emission spectrometry. In the present system, all REEs could be detected simultaneously in a single chromatographic measurement without spectral interferences. Utilizing a cation exchange column and 2-hydroxy-2-methylpropanoic acid aqueous solution as the mobile phase, the detection limits of 0.4-30 ng ml -1 for all REEs were obtained. The system was applied to the determination of REEs in geological standard rock samples and rare earth impurities in high purity rare earth oxides. The REEs in standard rocks could be determined by the present HPLC/ICP-AES system without pretreatment after acid digestion, although the detection limits were not sufficient for the analysis of rare earth oxides. (author)

  16. Development of a direct hydride generation nebulizer for the determination of selenium by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Carrion, Nereida; Murillo, Miguel; Montiel, Edie; Diaz, Dorfe

    2003-01-01

    A study was conducted to evaluate the performance of a new direct hydride generation nebulizer system for determination of hydride forming elements by inductively coupled plasma optical emission spectroscopy. This system was designed and optimized to obtain the highest sensitivity. Several experimental designs were used for these purposes. To optimize the individual parameters of the system, and to study the interaction between these parameters for both direct hydride generation nebulizers, a central composite orthogonal design with eight factors was set up. Significant behavioral differences were observed in the two direct hydride generation nebulizers studied. Finally, a 70 μm gas orifice nebulizer exhibits a better detection limit than the 120 μm nebulizer. Generally, for determination of selenium, this new direct hydride generation nebulizer system exhibits a linear dynamic range and detection limit (3σb) of 3 orders of magnitude and 0.2 μg l -1 for selenium, respectively. This new hydride generator is much simpler system that conventional hydride generation systems, which does not need to be changed to work in normal mode with the inductively coupled plasma, since this system may be used for hydride forming elements and those that do not form them. It produces a rapid response with low memory effect. It reduces the interference level of Ni, Co and Cu to 600, 500 and 5 mg l -1 , respectively. The accuracy of the system was verified by the determination of selenium in several standard reference materials of ambient, food and clinical sample matrices. No statistically significant differences (95 confidence level) were obtained between our method and the reference values

  17. Determination of inorganic beryllium species in the particulate matter of emissions and working areas

    Energy Technology Data Exchange (ETDEWEB)

    Profumo, A.; Spini, G.; Cucca, L.; Pesavento, M. [Dipartimento di Chimica Gen., Pavia (Italy)

    2002-07-01

    A sequential extraction procedure for separating and determining Be(0), soluble Be(II) inorganic compounds, BeO and beryllium silicates in samples, such as particulate matter of emissions and working areas, has been developed. The proposed procedure has been tested on synthetic samples prepared with the inorganic beryllium compounds, in the presence of atmospherical particulate matter sampled in a laboratory, previously checked for the absence of beryllium. The speciation was then repeated on a sample of fly ash deriving from a solid waste incinerator and on a reference material (Coal Fly ash SRM 1633a, by NIST), followed by an evaluation of matrix spiking and recovery analyses. Performing multiple analyses of the spiked samples assessed the repeatability of the procedure. Quantitative determinations have been made by inductively coupled plasma optical emission spectrometry (ICP-OES) and electrothermal atomic absorption spectrometry (ETAAS). The possible interferences of the most common ions have been investigated. The selective sequential extractions allow one to separate and to determine different inorganic beryllium species, to which a different toxicity and therefore, a different risk are related: it is the case for example of metallic beryllium and beryllium oxide.

  18. Study of optical emission spectroscopy with inductively coupled plasma torch

    International Nuclear Information System (INIS)

    Bauer, M.

    1982-01-01

    Inductively coupled plasma optical emission spectroscopy is an excellent tool for quantitative multielement trace analysis. This paper describes the performance of a computer-controlled sequential measurement system. Chemical and ionization interferences are shown to be negligible due to the characteristics of the inductively coupled plasma, spectral interferences are eliminated by using a high-resolution monochromator and computer data handling. Good accuracy is achieved for most of the interesting elements, as is shown from both an interlaboratory test and from comparison of the results of water samples from the rivers Elbe and Weser with those achieved with neutron activation and X-ray fluorescence analysis. (orig.) [de

  19. Methods for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry

    Science.gov (United States)

    Chan, George C. Y. [Bloomington, IN; Hieftje, Gary M [Bloomington, IN

    2010-08-03

    A method for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry (ICP-AES). ICP-AES analysis is performed across a plurality of selected locations in the plasma on an unknown sample, collecting the light intensity at one or more selected wavelengths of one or more sought-for analytes, creating a first dataset. The first dataset is then calibrated with a calibration dataset creating a calibrated first dataset curve. If the calibrated first dataset curve has a variability along the location within the plasma for a selected wavelength, errors are present. Plasma-related errors are then corrected by diluting the unknown sample and performing the same ICP-AES analysis on the diluted unknown sample creating a calibrated second dataset curve (accounting for the dilution) for the one or more sought-for analytes. The cross-over point of the calibrated dataset curves yields the corrected value (free from plasma related errors) for each sought-for analyte.

  20. Utilization of atomic emission spectroscopy methods for determination of rare earth elements

    International Nuclear Information System (INIS)

    Kubova, J.; Polakovicova, J.; Medved, J.; Stresko, V.

    1997-01-01

    The authors elaborated and applied procedures for rare earth elements (REE) determination using optical emission spectrograph with D.C arc excitation and ICP atomic emission spectrometry.Some of these analytical method are described. The proposed procedure was applied for the analysis of different types of geological materials from several Slovak localities. The results the REE determination were used for e.g. investigation of REE distribution in volcanic rocks, rhyolite tuffs with uranium-molybdenum mineralization, sandstones with heavy minerals accumulations, phosphatic sandstones, granites, quartz-carbonate veins and in the meteorite found in the locality Rumanova. The REE contents were determined in 19 mineral water sources and the results obtained by the both mentioned methods compared. The total REE contents in the analysed mineral water samples were between 2 · 10 -7 and 3 · 10 -5 g dm -3

  1. Diagnosis of the local thermal equilibrium by optical emission spectroscopy in the evolution of electric discharge

    International Nuclear Information System (INIS)

    Valdivia B, R.; Pacheco S, J.; Pacheco P, M.; Ramos F, F.; Cruz A, A.; Velazquez P, S.

    2008-01-01

    In this work applies the technique of optical emission spectroscopy to diagnose the temperature of the species generated in plasma in the transition to glow discharge arc. Whit this diagnosis is possible to determine the local thermal equilibrium conditions of the discharge. (Author)

  2. Energy and Emission Characteristics of a Short-Arc Xenon Flash Lamp Under "Saturated" Optical Brightness Conditions

    Science.gov (United States)

    Kamrukov, A. S.; Kireev, S. G.; Kozlov, N. P.; Shashkovskii, S. G.

    2017-09-01

    We present the results of a study of the electrical, energy, and spectral brightness characteristics of an experimental three-electrode high-pressure xenon flash lamp under conditions ensuring close to maximum possible spectral brightness for the xenon emission. We show that under saturated optical brightness conditions (brightness temperature in the visible region of the spectrum 30,000 K), emission of a pulsed discharge in xenon is quite different from the emission from an ideal blackbody: the maximum brightness temperatures are 24,000 K in the short-wavelength UV region and 19,000 K in the near IR range. The relative fraction of UV radiation in the emission spectrum of the lamp is >50%, which lets us consider such lamps as promising broadband sources of radiation with high spectral brightness for many important practical applications.

  3. Tuning direct bandgap GeSn/Ge quantum dots' interband and intraband useful emission wavelength: Towards CMOS compatible infrared optical devices

    Science.gov (United States)

    Baira, Mourad; Salem, Bassem; Madhar, Niyaz Ahamad; Ilahi, Bouraoui

    2018-05-01

    In this work, interband and intraband optical transitions from direct bandgap strained GeSn/Ge quantum dots are numerically tuned by evaluating the confined energies for heavy holes and electrons in D- and L-valley. The practically exploitable emission wavelength ranges for efficient use in light emission and sensing should fulfill specific criteria imposing the electrons confined states in D-valley to be sufficiently below those in L-valley. This study shows that GeSn quantum dots offer promising opportunity towards high efficient group IV based infrared optical devices operating in the mid-IR and far-IR wavelength regions.

  4. Inductively coupled plasma emission spectrometric detection of simulated high performance liquid chromatographic peaks

    International Nuclear Information System (INIS)

    Fraley, D.M.; Yates, D.; Manahan, S.E.

    1979-01-01

    Because of its multielement capability, element-specificity, and low detection limits, inductively coupled plasma optical emission spectrometry (ICP) is a very promising technique for the detection of specific elemental species separated by high performance liquid chromatography (HPLC). This paper evaluated ICP as a detector for HPLC peaks containing specific elements. Detection limits for a number of elements have been evaluated in terms of the minimum detectable concentration of the element at the chromatographic peak maximum. The elements studies were Al, As, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Sr, Ti, V, and Zn. In addition, ICP was compared with atomic absorption spectrometry for the detection of HPLC peaks composed of EDTA and NTA chelates of copper. Furthermore, ICP was compared to uv solution absorption for the detection of copper chelates. 6 figures, 4 tables

  5. Flame emission spectroscopy measurement of a steam blast and air blast burner

    Directory of Open Access Journals (Sweden)

    Jozsa Viktor

    2017-01-01

    Full Text Available Control and online monitoring of combustion have become critical to meet the increasingly strict pollutant emission standards. For such a purpose, optical sensing methods, like flame emission spectrometry, seem to be the most feasible technique. Spectrometry is capable to provide information about the local equivalence ratio inside the flame through the chemiluminescence intensity ratio measurement of various radicals. In the present study, a 15 kW atmospheric burner was analyzed utilizing standard diesel fuel. Its plain jet type atomizer was operated with both air and steam atomizing mediums. Up to now, injection of steam into the reaction zone has attracted less scientific attention contrary to its practical importance. Spatial plots of OH*, CH*, and C2* excited radicals were analyzed at 0.35, 0.7, and 1 bar atomization gauge pressures, utilizing both atomizing mediums. The C2* was found to decrease strongly with increasing steam addition. The OH*/CH* and OH*/C2* chemiluminescence intensity ratios along the axis showed a divergent behavior in all the analyzed cases. Nevertheless, CH*/C2* chemiluminescence intensity ratio decreased only slightly, showing low sensitivity to the position of the spectrometer. The findings may be directly applied in steady operating combustion systems, i. e., gas turbines, boilers, and furnaces.

  6. Search for GRB related prompt optical emission and other fast varying objects with ``Pi of the Sky'' detector

    Science.gov (United States)

    Ćwiok, M.; Dominik, W.; Małek, K.; Mankiewicz, L.; Mrowca-Ciułacz, J.; Nawrocki, K.; Piotrowski, L. W.; Sitek, P.; Sokołowski, M.; Wrochna, G.; Żarnecki, A. F.

    2007-06-01

    Experiment “Pi of the Sky” is designed to search for prompt optical emission from GRB sources. 32 CCD cameras covering 2 steradians will monitor the sky continuously. The data will be analysed on-line in search for optical flashes. The prototype with 2 cameras operated at Las Campanas (Chile) since 2004 has recognised several outbursts of flaring stars and has given limits for a few GRB.

  7. Accuracy and Precision in Elemental Analysis of Environmental Samples using Inductively Coupled Plasma-Atomic Emission Spectrometry

    International Nuclear Information System (INIS)

    Quraishi, Shamsad Begum; Chung, Yong-Sam; Choi, Kwang Soon

    2005-01-01

    Inductively Coupled Plasma-Atomic Emission Spectrometry followed by micro-wave digestion have been performed on different environmental Certified Reference Materials (CRMs). Analytical results show that accuracy and precision in ICP-AES analysis were acceptable and satisfactory in case of soil and hair CRM samples. The relative error of most of the elements in these two CRMs is within 10% with few exceptions and coefficient of variation is also less than 10%. Z-score as an analytical performance was also within the acceptable range (±2). ICP-AES was found as an inadequate method for Air Filter CRM due to incomplete dissolution, low concentration of elements and very low mass of the sample. However, real air filter sample could have been analyzed with high accuracy and precision by increasing sample mass during collection. (author)

  8. Analysis of the emission characteristics of ion sources for high-value optical counting processes

    International Nuclear Information System (INIS)

    Beermann, Nils

    2009-01-01

    The production of complex high-quality thin film systems requires a detailed understanding of all partial processes. One of the most relevant partial processes is the condensation of the coating material on the substrate surface. The optical and mechanical material properties can be adjusted by the well-defined impingement of energetic ions during deposition. Thus, in the past, a variety of different ion sources were developed. With respect to the present and future challenges in the production of precisely fabricated high performance optical coatings, the ion emission of the sources has commonly not been characterized sufficiently so far. This question is addressed in the frame of this work which itself is thematically integrated in the field of process-development and -control of ion assisted deposition processes. In a first step, a Faraday cup measurement system was developed which allows the spatially resolved determination of the ion energy distribution as well as the ion current distribution. Subsequently, the ion emission profiles of six ion sources were determined depending on the relevant operating parameters. Consequently, a data pool for process planning and supplementary process analysis is made available. On the basis of the acquired results, the basic correlations between the operating parameters and the ion emission are demonstrated. The specific properties of the individual sources as well as the respective control strategies are pointed out with regard to the thin film properties and production yield. Finally, a synthesis of the results and perspectives for future activities are given. (orig.)

  9. A microfabricated, low dark current a-Se detector for measurement of microplasma optical emission in the UV for possible use on-site

    Science.gov (United States)

    Abbaszadeh, Shiva; Karim, Karim S.; Karanassios, Vassili

    2013-05-01

    Traditionally, samples are collected on-site (i.e., in the field) and are shipped to a lab for chemical analysis. An alternative is offered by using portable chemical analysis instruments that can be used on-site (i.e., in the field). Many analytical measurements by optical emission spectrometry require use of light-sources and of spectral lines that are in the Ultra-Violet (UV, ~200 nm - 400 nm wavelength) region of the spectrum. For such measurements, a portable, battery-operated, fiber-optic spectrometer equipped with an un-cooled, linear, solid-state detector may be used. To take full advantage of the advanced measurement capabilities offered by state-of-the-art solid-state detectors, cooling of the detector is required. But cooling and other thermal management hamper portability and use on-site because they add size and weight and they increase electrical power requirements. To address these considerations, an alternative was implemented, as described here. Specifically, a microfabricated solid-state detector for measurement of UV photons will be described. Unlike solid-state detectors developed on crystalline Silicon, this miniaturized and low-cost detector utilizes amorphous Selenium (a-Se) as its photosensitive material. Due to its low dark current, this detector does not require cooling, thus it is better suited for portable use and for chemical measurements on-site. In this paper, a microplasma will be used as a light-source of UV photons for the a-Se detector. For example, spectra acquired using a microplasma as a light-source will be compared with those obtained with a portable, fiber-optic spectrometer equipped with a Si-based 2080-element detector. And, analytical performance obtained by introducing ng-amounts of analytes into the microplasma will be described.

  10. Optical characterization, 1.5 μm emission and IR-to-visible energy upconversion in Er3+-doped fluorotellurite glasses

    International Nuclear Information System (INIS)

    Rodriguez-Mendoza, U.R.; Lalla, E.A.; Caceres, J.M.; Rivera-Lopez, F.; Leon-Luis, S.F.; Lavin, V.

    2011-01-01

    The optical properties of Er 3+ ions in a novel glass based on TeO 2 -PbF 2 -AlF 3 oxyfluoride tellurites have been investigated using steady-state and time-resolved spectroscopies as a function of the rare-earth doping concentration. Basic optical characterizations have been performed measuring and calculating the absorption and emission spectra and the cross-sections, the Judd-Ofelt intensity parameters, the radiative probabilities and the fluorescence decays and lifetimes. Special attention has been devoted to the broad 4 I 13/2 → 4 I 15/2 emission transition at around 1.53 μm since, with a wide broadening of around 70 nm and a relative long lifetime of around 3 ms compared to others glass hosts, it shows potential applications in the design of erbium-doped fiber amplifiers. The absorption, the stimulated emission and the gain cross-sections of this transition have been obtained and compared with that obtained in different hosts. Finally, infrared-to-visible upconversion processes exciting at around 800 nm have been analyzed and different mechanisms involved in the energy conversion have been proposed. - Research highlights: → Broadened emission bands and high absorption and emission cross-sections for the transition 4 I 15/2 → 4 I 13/2 suitable for EDFAs. → Efficient green upconverted emission. → High value of C DA (6) energy transfer parameter.

  11. Morphology and Optical Properties of Black-Carbon Particles Relevant to Engine Emissions

    Science.gov (United States)

    Michelsen, H. A.; Bambha, R.; Dansson, M. A.; Schrader, P. E.

    2013-12-01

    Black-carbon particles are believed to have a large influence on climate through direct radiative forcing, reduction of surface albedo of snow and ice in the cryosphere, and interaction with clouds. The optical properties and morphology of atmospheric particles containing black carbon are uncertain, and characterization of black carbon resulting from engines emissions is needed. Refractory black-carbon particles found in the atmosphere are often coated with unburned fuel, sulfuric acid, water, ash, and other combustion by-products and atmospheric constituents. Coatings can alter the optical and physical properties of the particles and therefore change their optical properties and cloud interactions. Details of particle morphology and coating state can also have important effects on the interpretation of optical diagnostics. A more complete understanding of how coatings affect extinction, absorption, and incandescence measurements is needed before these techniques can be applied reliably to a wide range of particles. We have investigated the effects of coatings on the optical and physical properties of combustion-generated black-carbon particles using a range of standard particle diagnostics, extinction, and time-resolved laser-induced incandescence (LII) measurements. Particles were generated in a co-flow diffusion flame, extracted, cooled, and coated with oleic acid. The diffusion flame produces highly dendritic soot aggregates with similar properties to those produced in diesel engines, diffusion flames, and most natural combustion processes. A thermodenuder was used to remove the coating. A scanning mobility particle sizer (SMPS) was used to monitor aggregate sizes; a centrifugal particle mass analyzer (CPMA) was used to measure coating mass fractions, and transmission electron microscopy (TEM) was used to characterize particle morphologies. The results demonstrate important differences in optical measurements between coated and uncoated particles.

  12. Determination of ultratrace elements in natural waters by solid-phase extraction and atomic spectrometry methods.

    Science.gov (United States)

    Grotti, Marco; Abelmoschi, Maria Luisa; Soggia, Francesco; Frache, Roberto

    2003-01-01

    A study was carried out on the preconcentration of ultratrace amounts of cadmium, lead, manganese, copper and iron from high-salinity aqueous samples and determination by atomic spectrometry methods. Sample volume, amount of resin, loading flow rate, and elution volume were optimized in order to obtain the simultaneous preconcentration of all the analytes. Quantitative recoveries were obtained by using 200 mg of iminodiacetic resin with a loading flow rate of 2 mL min(-1), elution volume of 3 mL and sample volume of 50-450 mL. Only copper in seawater samples was not completely retained by the resin (60-70% recovery), due to unfavorable competition of iminodiacetic-active groups with organically bound metal.To quantify the metals in the eluates, two atomic spectrometry techniques were compared: electrothermal atomization atomic absorption spectrometry (ETAAS) and inductively coupled plasma-optical emission spectrometry (ICP-OES) with simultaneous CCD detection system. Both techniques are suitable for sample analysis with detection limits of 1.0, 4.7, 3.3, 6.8, and 53 ng L(-1) using ETAAS and 12, 122, 3.4, 17, and 21 ng L(-1) using ICP-OES for Cd, Pb, Mn, Cu, and Fe, respectively. Relative standard deviations of the procedures ranged from 1.7 to 14% at the sub-microg L(-1) concentration level. The accuracy of both methods was verified by analyzing various certified reference materials (river water, estuarine water, coastal and off-shore seawater).

  13. Determination of ultratrace elements in natural waters by solid-phase extraction and atomic spectrometry methods

    Energy Technology Data Exchange (ETDEWEB)

    Grotti, Marco; Abelmoschi, Maria Luisa; Soggia, Francesco; Frache, Roberto [Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso, 31-16146, Genoa (Italy)

    2003-01-01

    A study was carried out on the preconcentration of ultratrace amounts of cadmium, lead, manganese, copper and iron from high-salinity aqueous samples and determination by atomic spectrometry methods. Sample volume, amount of resin, loading flow rate, and elution volume were optimized in order to obtain the simultaneous preconcentration of all the analytes. Quantitative recoveries were obtained by using 200 mg of iminodiacetic resin with a loading flow rate of 2 mL min{sup -1}, elution volume of 3 mL and sample volume of 50-450 mL. Only copper in seawater samples was not completely retained by the resin (60-70% recovery), due to unfavorable competition of iminodiacetic-active groups with organically bound metal.To quantify the metals in the eluates, two atomic spectrometry techniques were compared: electrothermal atomization atomic absorption spectrometry (ETAAS) and inductively coupled plasma-optical emission spectrometry (ICP-OES) with simultaneous CCD detection system. Both techniques are suitable for sample analysis with detection limits of 1.0, 4.7, 3.3, 6.8, and 53 ng L{sup -1} using ETAAS and 12, 122, 3.4, 17, and 21 ng L{sup -1} using ICP-OES for Cd, Pb, Mn, Cu, and Fe, respectively. Relative standard deviations of the procedures ranged from 1.7 to 14% at the sub-{mu}g L{sup -1} concentration level. The accuracy of both methods was verified by analyzing various certified reference materials (river water, estuarine water, coastal and off-shore seawater). (orig.)

  14. Optical emission studies of atomic and ionic species in the ionized sputter-deposition process of magnesium oxide thin films

    International Nuclear Information System (INIS)

    Matsuda, Y.; Koyama, Y.; Iwaya, M.; Shinohara, M.; Fujiyama, H.

    2005-01-01

    Planar magnetron (PM) power and ICP-RF power dependences of the optical emission intensities of excited atomic and ionic species in the reactive ionized sputter-deposition of magnesium oxide (MgO) thin films were investigated. With the increase in PM power at constant ICP-RF power, Mg I emission intensity increased and Ar I emission intensity gradually decreased. With the increase in ICP-RF power at constant PM power, the Mg I emission intensity increased at lower ICP-RF power and then gradually decreased at higher ICP-RF power; on the contrary, Ar I emission intensity monotonically increased. Emission intensity of atomic oxygen was negligibly small compared with those of Mg I and Ar I under the metallic sputtering mode condition

  15. Study of material properties important for an optical property modulation-based radiation detection method for positron emission tomography

    OpenAIRE

    Tao, Li; Daghighian, Henry M.; Levin, Craig S.

    2017-01-01

    We compare the performance of two detector materials, cadmium telluride (CdTe) and bismuth silicon oxide (BSO), for optical property modulation-based radiation detection method for positron emission tomography (PET), which is a potential new direction to dramatically improve the annihilation photon pair coincidence time resolution. We have shown that the induced current flow in the detector crystal resulting from ionizing radiation determines the strength of optical modulation signal. A large...

  16. Evaluation of analytical procedures for the determination of cadmium, boron and lithium in UALx samples by inductively coupled plasma optical emission spectrometry (ICP OES)

    International Nuclear Information System (INIS)

    Guilhen, Sabine Neusatz; Kakazu, Mauricio H.; Cotrim, Marycel Elena Barboza; Pires, Maria Aparecida Faustino; Souza, Alexandre Luiz de

    2013-01-01

    Used in over 80% of the worldwide diagnostic procedures, Technetium-99m ( 99m Tc), which is obtained from the decay of molybdenum-99 ( 99 Mo), is the most important radioisotope in nuclear medicine. IPEN/CNEN-SP has been developing technologies in order to produce Mo-99 by the irradiation of low-enriched uranium (LEU < 20% of 235U) targets in its research reactor IEA-R1 (IPEN, Sao Paulo/Brazil). These targets consist of low enriched uranium dispersed in a matrix of aluminum (UAlx-Al). Several impurities may be incorporated during the target's production process, such as boron, cadmium and lithium, which have a high capture cross section that may reduce the irradiation's efficiency. This study describes a simple and rapid inductively coupled plasma optical emission spectrometric method for the determination of cadmium, boron and lithium in uranium aluminum (UAlx) dispersion targets. The method involves a previous separation step, in which uranium gets removed from the matrix by chromatographic extraction with the use of a divinylbenzene resin Amberlite XAD - 4 doped with tri-n-butyl phosphate (TBP). TBP selectively separates the uranium, leaving behind the impurities in an aqueous medium for a further quantification by ICP OES. Possible spectroscopic interferences are also discussed in this article, because of the high amount of aluminum in the remaining solution. Experimental and instrumental conditions, such as initial mass, acid solution ratio and amount, resin mass, emission lines and interfering concentrations are carefully established. This method is to be applied for the determination of several others impurities in UAlx in the future, providing means to verify the UAlx targets' compliance to the current established specifications through routine laboratory analysis. (author)

  17. Development of quantitative analysis for cadmium, lead and chromium in aluminum alloys by using x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Yamashita, Satoshi; Kurusu, Kazuhiko; Kudou, Aiko

    2009-01-01

    A highly reliable quantitative analysis for cadmium, lead and chromium in aluminum alloys was developed. Standard samples were made by doping cadmium, lead and chromium into several aluminum alloys, and the composition of standard samples were determined by inductively coupled plasma optical emission spectrometry and gravimetric method. The calibration curves for these standard samples by using WD-XRF and ED-XRF exhibited linear correlation. Slope of calibration curves for Al-Cu alloy and Al-Zn-Mg alloy were smaller than other alloy's one, because of the effect by coexistent elements. Then, all calibration curves agreed with each other by performing correction with α-coefficient method. (author)

  18. Optical characterization of extremely small volumes of liquid in sub-micro-holes by simultaneous reflectivity, ellipsometry and spectrometry.

    Science.gov (United States)

    Holgado, M; Casquel, R; Sánchez, B; Molpeceres, C; Morales, M; Ocaña, J L

    2007-10-01

    We have fabricated and characterized a lattice of submicron cone-shaped holes on a SiO(2)/Si wafer. Reflectivity profiles as a function of angle of incidence and polarization, phase shift and spectrometry are obtained for several fluids with different refractive indexes filling the holes. The optical setup allows measuring in the center of a single hole and collecting all data simultaneously, which can be applied for measuring extremely low volumes of fluid (in the order of 0.1 femtolitres) and label-free immunoassays, as it works as a refractive index sensor. A three layer film stack model is defined to perform theoretical calculations.

  19. Optical emission from low-energy ion-surface collisions

    International Nuclear Information System (INIS)

    White, C.W.; Thomas, E.W.; Van der Weg, W.F.; Tolk, N.H.

    1977-01-01

    Impact of energetic heavy particles on surfaces gives rise to emission of optical radiation from reflected particles, sputtered particles and also from excited states of the solid. The present status of research in this area is reviewed with emphasis on understanding the basic mechanisms which give rise to formation of excited states. The spectral line shape from ejected atoms may be analyzed to provide information on the distribution of speeds and directions of the excited species; the line intensity provides a measure of the probability for creating the state. Formation of excited species is related both to the collision processes within the solid and also to the interaction of the recoiling ejected species with the target surface. Most ejected species are atomic but important examples of ejected molecules are also discussed. Luminescence induced in the solid itself is related to recombination of electron hole pairs and is related significantly to the presence of defects

  20. Flow injection analysis in inductively coupled plasma spectrometry

    International Nuclear Information System (INIS)

    Rosias, Maria F.G.G.

    1995-10-01

    The main features of flow injection analysis (FIA) as contribution to the inductively coupled plasma (Icp) spectrometry are described. A systematic review of researches using the combined FIA-Icp and the benefits of this association are presented. Flow systems were proposed to perform on-line Icp solution management for multielemental determination by atomic emission spectrometry (Icp-AES) or mass spectrometry. The inclusion of on-line ion exchangers in flow systems for matrix separation and/or analyte preconcentration are presented. Together with those applications the new advent of instruments with facilities for multielement detection on flow injection signals are described. (author). 75 refs., 19 figs

  1. Semi-automatic determination of tin in marine materials by continuous flow hydride generation inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Feng Yonglai; Narasaki, Hisataki; Chen Hongyuan; Tian Liching

    1997-01-01

    A semi-automated continuous flow hydride generation system with inductively coupled plasma atomic emission spectrometry (ICP-AES) was used for the determination of tin in marine materials. The effects of acids (H 2 SO 4 and HCl) were studied. The analytical parameters were thoroughly investigated. Under optimized conditions, the detection limit is 0.4 ng/ml. Interferences from transition elements were investigated and seven masking reagents were tested. L-cysteine hydrochloride monohydrate (1%) was used to mask the interferences from foreign ions. Finally, the accuracy, checked with a marine standard reference material obtained from the National Research Council (NRC), was within the certified value. (orig.). With 6 figs., 4 tabs

  2. Determination of trace elements in paints by direct sampling graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Bentlin, Fabrina R.S.; Pozebon, Dirce; Mello, Paola A.; Flores, Erico M.M.

    2007-01-01

    A direct sampling graphite furnace atomic absorption spectrometric (DS-GFAAS) method for the determination of Cd, Pb, Cr, Ni, Co and Cu in paints has been developed. Serigraphy, acrylic and tattoo paints were analysed. Approaches like pyrolysis and atomization temperatures, modifiers and sample mass introduced in the atomizer were studied. Quantification was performed using calibration curves measured with aqueous standard solutions pipetted onto the platform. The sample mass introduced in the graphite tube ranged from 0.02 to 8.0 mg. Palladium was used as modifier for Cd, Pb and Cu, while Mg(NO 3 ) 2 was used for Co. For Ni determination, the graphite platform was covered with carbon powder. The characteristic masses of Cd, Pb, Cr, Ni, Co and Cu were 1.4, 22.5, 7.9, 11.0, 9.6 and 12.5 pg, while the limits of detection were 0.0004, 0.001, 0.03, 0.22, 0.11 and 0.05 μg g -1 of Cd, Pb, Cr, Ni, Co and Cu, respectively. The accuracy was determined by comparison of the results with those obtained by inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GFAAS), using liquid sampling of digests. For matrix characterization, major and minor elements (Al, Mg, Ba, Ca, Cr, Cu, Pb, Sr, Ti and Mg) were determined by inductively coupled plasma optical emission spectrometry (ICP OES)

  3. Optical properties of highly Er{sup 3+}-doped sodium-aluminium-phosphate glasses for broadband 1.5 {mu}m emission

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, A. Amarnath [Nanophotonics Laboratory, Department of Physics, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016 (India); Babu, S. Surendra [Laser Instrumentation Design Centre, Instrument Research and Development Establishment, Dehradun 248008 (India); Pradeesh, K. [Nanophotonics Laboratory, Department of Physics, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016 (India); Otton, C.J. [Valencia Nanophotonics Technology Center, Universidad Politecnica de Valencia, 46022 Valencia (Spain); Vijaya Prakash, G., E-mail: prakash@physics.iitd.ac.in [Nanophotonics Laboratory, Department of Physics, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016 (India)

    2011-03-03

    Research highlights: > Highly Er{sup 3+} doped phosphate glasses for the 1.54 {mu}m laser emission were explored. > Emission from these doped glasses shows larger lifetimes and quantum efficiencies. > Optical amplifier parameters are greater than other reported phosphate glasses. > The durability and obtained results are most favourable for short-length amplifiers. - Abstract: Erbium-doped Na{sub 3}Al{sub 2}P{sub 3}O{sub 12} (NAP) glasses with compositions 92NAP-(8-x)Al{sub 2}O{sub 3}-(x)Er{sub 2}O{sub 3} (where x = 2-8) were prepared and characterized for absorption, visible and NIR emission and decay time properties. Judd-Ofelt analysis has been carried out to predict radiative properties of luminescent levels of Er{sup 3+} ions. Comparatively larger photoluminescence lifetimes (7.86 ms) and larger quantum efficiencies (74%) for the laser transition, {sup 4}I{sub 13/2} {yields} {sup 4}I{sub 15/2} (at 1.54 {mu}m) are observed. The moisture insensitivity, large Er{sup 3+} ion doping capability and relatively high-gain and broad emission at 1.5 {mu}m are the most notable features of these glasses to realize efficient short-length optical amplifiers.

  4. Correlated X-ray/UV/optical emission and short-term variability in a Seyfert 1 galaxy NGC 4593

    Science.gov (United States)

    Pal, Main; Naik, Sachindra

    2018-03-01

    We present a detailed multifrequency analysis of an intense monitoring programme of Seyfert 1 galaxy NGC 4593 over a duration of nearly for a month with Swift observatory. We used 185 pointings to study the variability in six ultraviolet/optical and two soft (0.3-1.5 keV) and hard X-ray (1.5-10 keV) bands. The amplitude of the observed variability is found to decrease from high energy to low energy (X-ray to optical) bands. Count-count plots of ultraviolet/optical bands with hard X-rays clearly suggest the presence of a mixture of two major components: (i) highly variable component such as hard X-ray emission, and (ii) slowly varying disc-like component. The variations observed in the ultraviolet/optical emission are strongly correlated with the hard X-ray band. Cross-correlation analysis provides the lags for the longer wavelengths compared to the hard X-rays. Such lags clearly suggest that the changes in the ultraviolet/optical bands follow the variations in the hard X-ray band. This implies that the observed variation in longer wavelengths is due to X-ray reprocessing. Though, the measured lag spectrum (lag versus wavelength) is well described by λ4/3 as expected from the standard disc model, the observed lags are found to be longer than the predicted values from standard disc model. This implies that the actual size of the disc of NGC 4593 is larger than the estimated size of standard thin disc as reported in active galactic nuclei such as NGC 5548 and Fairall 9.

  5. Critical Temperature for the Conversion from Wurtzite to Zincblende of the Optical Emission of InAs Nanowires

    KAUST Repository

    Rota, Michele B.; Ameruddin, Amira S.; Wong-Leung, Jennifer; Belabbes, Abderrezak; Gao, Qiang; Miriametro, Antonio; Mura, Francesco; Tan, Hark Hoe; Polimeni, Antonio; Bechstedt, Friedhelm; Jagadish, Chennupati; Capizzi, Mario

    2017-01-01

    One hour annealing at 300 degrees C changes the optical emission characteristics of InAs nanowires (NWs) from the wurtzite (WZ) phase into that of zincblende (ZB). These results are accounted for by the conversion of a small fraction of the NW WZ

  6. Spatial discrimination against background with different optical systems for collection of fluorescence in laser-excited atomic fluorescence spectrometry with a graphite tube electrothermal atomizer.

    Science.gov (United States)

    Yuzefovsky, A I; Lonardo, R F; Michel, R G

    1995-07-01

    A single 90 degrees off-axis ellipsoidal mirror fragment was used in a dispersive detection system for electrothermal atomization laser-excited atomic fluorescence spectrometry. The performance of the new optical arrangement was compared with those of optical arrangements that employed a plane mirror in combination with biconvex or plano-convex lenses. All the optical arrangements collected fluorescence in a scheme called front surface illustration. BEAM-4, an optical ray tracing program, was used for calculations of spatial ray distributions and optical collection efficiency for the various optical configurations. Experimentally, the best collection efficiency was obtained by use of the ellipsoidal mirror, in qualitative agreement with simulations done by use of the BEAM-4 software. The best detection limit for cobalt with the new optical arrangement was 20 fg, which was a factor of 5 better than that obtained with conventional optical arrangements with otherwise the same instrumentation. The signal-to-background ratio and the fluorescence collection efficiency were also studied as a function of position of the optical components for the various optical arrangements. For both cobalt and phosphorus, the signal-to-background ratio with the new optical arrangement remained stable within 10-20% during +/- 8 mm shifts in the position of the detection system from the focal plane of the optics. Overall, the new optical arrangement offered high collection efficiency, excellent sensitivity, and facile optical alignment due to efficient spatial separation between the fluorescence signal and the background radiation. The advantages of the new optical arrangement were particularly important during measurements in the presence of high levels of blackbody radiation.

  7. Inductively coupled plasma as atomization, excitation and ionization sources in analytical atomic spectrometry

    International Nuclear Information System (INIS)

    Kawaguchi, Hiroshi

    1996-01-01

    Studies on inductively coupled plasma (ICP) for atomic emission and mass spectrometry accomplished in our laboratory since 1978 are reviewed. In emission spectrometry, the characteristics of the plasma are studied concerning the spatial profiles of spectral line intensity, axial profiles of gas and excitation temperatures, spectral line widths and matrix effect. The studies are particularly emphasized on the instrumentation such as developments of plasma generator, emission spectrometers, water-cooled torches and sample introduction methods. A slew-scan type spectrometer developed in these works represents a predecessor of the current commercial spectrometers. An ICP mass spectrometer was first developed in Japan in this laboratory in 1984. Non-spectroscopic interference of this method was found to have the correlation with the atomic weight of the matrix element. Plasma gases other than argon such as nitrogen and oxygen were used for the ICP to evaluate their performance in mass spectrometry as for the sensitivity and interferences. (author). 63 refs

  8. Glow Discharge Emission Spectrometry (GDOES): Theoretical Introduction, General Aspects, and its Applications within the Framework of the Technofusion Programs

    International Nuclear Information System (INIS)

    Martin-Rojo, A. B.; Gonzalez, M.; Tabares, F. L.

    2013-01-01

    The demand by material research groups for the direct composition analysis of solids is increasing as a solution to the time-consuming problems and errors inherent to classical chemical analysis, where the attack and solubilisation of the starting material is mandatory, often producing the introduction of impurities and component loss of the initial matrix. From the existing solid analysis techniques the present work is focused on the Glow Discharge Emission Spectrometry (GDOES), a fast, simply-executed technique, for which quantitative, high resolution depth profile determination of any element in the periodic table can be performed with a high sensibility and detection limit. The theoretical concepts, the required instrumentation and the basic analytic applications are revised, giving especial attention to the issues related to the analysis of materials for fusion applications. Finally, a comparative study with a more advanced spectroscopic technique (Secondary Ion Mass Spectrometry (SIMS)) is performed and the concomitance of both techniques to correct limitations such as the spatial resolution and the quantification of the analysis, important factors that are required in the chemical analysis of the complex materials used in Fusion, is addressed. (Author) 41 refs.

  9. Optical technologies applied alongside on-site and remote approaches for climate gas emission quantification at a wastewater treatment plant

    DEFF Research Database (Denmark)

    Samuelsson, Jerker; Delre, Antonio; Tumlin, Susanne

    2018-01-01

    Plant-integrated and on-site gas emissions were quantified from a Swedish wastewater treatment plant by applying several optical analytical techniques and measurement methods. Plant-integrated CH4 emission rates, measured using mobile ground-based remote sensing methods, varied between 28.5 and 33.......5 kg CH4 h−1, corresponding to an average emission factor of 5.9% as kg CH4 (kg CH4production) −1, whereas N2O emissions varied between 4.0 and 6.4 kg h−1, corresponding to an average emission factor of 1.5% as kg N2O-N (kg TN influent) −1. Plant-integrated NH3 emissions were around 0.4 kg h−1...... quantifications were approximately two-thirds of the plant-integrated emission quantifications, which may be explained by the different timeframes of the approaches and that not all emission sources were identified during on-site investigation. Off-site gas emission quantifications, using ground-based remote...

  10. Multicolor tuning towards single red-emission band of upconversion nanoparticles for tunable optical component and optical/x-ray imaging agents via Ce"3"+ doping

    International Nuclear Information System (INIS)

    Yi, Zhigao; Zeng, Tianmei; Xu, Yaru; Qian, Chao; Liu, Hongrong; Zeng, Songjun; Lu, Wei; Hao, Jianhua

    2015-01-01

    A simple strategy of Ce"3"+ doping is proposed to realize multicolor tuning and predominant red emission in BaLnF_5:Yb"3"+/Ho"3"+ (Ln"3"+ = Gd"3"+, Y"3"+, Yb"3"+) systems. A tunable upconversion (UC) multicolor output from green/yellow to red can be readily achieved in a fixed Yb"3"+/Ho"3"+ composition by doping Ce"3"+, providing an effective route for multicolor tuning widely used for various optical components. Moreover, compared with Ce"3"+-free UC nanoparticles (UCNPs), a remarkable enhancement of the red-to-green (R/G) ratio is observed by doping 30% Ce"3"+, arising from the two largely promoted cross-relaxation (CR) processes between Ce"3"+ and Ho"3"+. UCNPs with pure red emission are selected as in vivo UC bioimaging agents, demonstrating the merits of deep penetration depth, the absence of autofluorescence and high contrast in small animal bioimaging. Moreover, such fluorescence imaging nanoprobes can also be used as contrast agents for three-dimensional (3D) x-ray bioimaging by taking advantage of the high K-edge values and x-ray absorption coefficients of Ba"2"+, Gd"3"+, and Ce"3"+ in our designed nanoprobes. Thus, the simultaneous realization of multicolor output, highly enhanced R/G ratio, and predominant red emission makes the Ce"3"+-doped UCNPs very useful for widespread applications in optical components and bioimaging. (paper)

  11. Multicolor tuning towards single red-emission band of upconversion nanoparticles for tunable optical component and optical/x-ray imaging agents via Ce(3+) doping.

    Science.gov (United States)

    Yi, Zhigao; Zeng, Tianmei; Xu, Yaru; Lu, Wei; Qian, Chao; Liu, Hongrong; Zeng, Songjun; Hao, Jianhua

    2015-09-25

    A simple strategy of Ce(3+) doping is proposed to realize multicolor tuning and predominant red emission in BaLnF5:Yb(3+)/Ho(3+) (Ln(3+) = Gd(3+), Y(3+), Yb(3+)) systems. A tunable upconversion (UC) multicolor output from green/yellow to red can be readily achieved in a fixed Yb(3+)/Ho(3+) composition by doping Ce(3+), providing an effective route for multicolor tuning widely used for various optical components. Moreover, compared with Ce(3+)-free UC nanoparticles (UCNPs), a remarkable enhancement of the red-to-green (R/G) ratio is observed by doping 30% Ce(3+), arising from the two largely promoted cross-relaxation (CR) processes between Ce(3+) and Ho(3+). UCNPs with pure red emission are selected as in vivo UC bioimaging agents, demonstrating the merits of deep penetration depth, the absence of autofluorescence and high contrast in small animal bioimaging. Moreover, such fluorescence imaging nanoprobes can also be used as contrast agents for three-dimensional (3D) x-ray bioimaging by taking advantage of the high K-edge values and x-ray absorption coefficients of Ba(2+), Gd(3+), and Ce(3+) in our designed nanoprobes. Thus, the simultaneous realization of multicolor output, highly enhanced R/G ratio, and predominant red emission makes the Ce(3+)-doped UCNPs very useful for widespread applications in optical components and bioimaging.

  12. Use of magnesium as a test element for inductively coupled plasma atomic emission spectrometry diagnosis

    International Nuclear Information System (INIS)

    Mermet, J.M.

    1991-01-01

    To optimize atomization and ionization processes in an inductively coupled plasma used as a source in atomic emission spectrometry, the Mg II 280.270-nm/Mg I 285-213-nm line intensity ratio is used. A theoretic ratio is calculated assuming a local thermodynamic equilibrium.A review of previously published experimental values of the ratio is given as a function of the parameters influencing the energy transfer between the plasma and injected species. In particular, the effects of the power, the carrier gas flow-rate, the i.d. of the torch injector, the use of a sheathing gas and the presence of hydrogen are described. Values of the ratio close to the theoretical values are obtained with a high power (>1.4 kW), a lower carrier gas flow-rate ( -1 ) and a large i.d. of the injector (>2 mm). This optimization can also be applied to the minimization of interference effects due to the presence of sodium. (author). 64 refs.; 9 figs.; 1 tab

  13. Fiscal 1997 report on the results on the international standardization R and D. Development of chemical methods to analyze/evaluate metallic coatings of surface treated steel coating sheets; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Hyomen shori koban mekkiso no kagaku bunseki hyoka hoho no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The paper studied the international standardization of the chemical analysis method and glow discharge optical emission spectrometry. Chemical composition and coating thickness (g/m{sup 2}) of 14 kinds of specimens including alloy coatings and organic coating with zinc and aluminum as base were analyzed by the above-mentioned methods to examine the relation between the both. As the chemical analysis method, used was inductively coupled plasma atomic emission spectrometry. To study the relation between the methods, it was found to be necessary to recognize morphology at the boundary between the coating and base steel using, for example, scanning electron microscope (SEM) and electro-probe micro-analysis (EPMA). To measure traceability of the analysis method, with the chemical analysis method as a judgement method, it is necessary to make reference materials by coating materials, to use the calibration graph confirmed by the materials and to adopt the glow discharge optical emission spectrometry. On the basis of such way of thinking, drafts were worked out for the international standardization of the chemical analysis method and glow discharge optical emission spectrometry. 7 refs., 117 figs., 33 tabs.

  14. Training and assessment of experimental competencies from a distance: Optical spectrometry via the Internet

    Science.gov (United States)

    Thoms, L.-J.; Girwidz, R.

    2016-05-01

    Assessment of experimental competencies is not yet well established. We just began an empirical pilot study, too. This study aims to examine if secondary school students may successfully use a predefined remote lab activity to introduce themselves to atomic physics. The analysis of spectra is a fundamental component for the understanding of wave optics and color perception. Hence, every student should have the opportunity to conduct own optical emission experiments. Since spectrometers are expensive and an accurate calibration is necessary to achieve energy distribution spectra of high quality, we developed a remotely controlled laboratory. We evaluated the experimental set-up and the accompanying worksheet with groups of two to four students in a laboratory condition. Additionally, the emerged learning material was brought to school and tested as a homework activity with 9th-graders replacing the regular introduction to atomic physics. The results show that the experiment presented here can be used by ninth grade students and is useful in connection with the created material for the self-regulated introduction to atomic physics in the context of homework.

  15. Training and assessment of experimental competencies from a distance: Optical spectrometry via the Internet

    International Nuclear Information System (INIS)

    Thoms, L-J.; Girwidz, R.

    2015-01-01

    Assessment of experimental competencies is not yet well established. We just began an empirical pilot study, too. This study aims to examine if secondary school students may successfully use a predefined remote lab activity to introduce themselves to atomic physics. The analysis of spectra is a fundamental component for the understanding of wave optics and color perception. Hence, every student should have the opportunity to conduct own optical emission experiments. Since spectrometers are expensive and an accurate calibration is necessary to achieve energy distribution spectra of high quality, we developed a remotely controlled laboratory. We evaluated the experimental set-up and the accompanying worksheet with groups of two to four students in a laboratory condition. Additionally, the emerged learning material was brought to school and tested as a homework activity with 9.-graders replacing the regular introduction to atomic physics. The results show that the experiment presented here can be used by ninth grade students and is useful in connection with the created material for the self-regulated introduction to atomic physics in the context of homework.

  16. Synthetic nebular emission from massive galaxies - I: origin of the cosmic evolution of optical emission-line ratios

    Science.gov (United States)

    Hirschmann, Michaela; Charlot, Stephane; Feltre, Anna; Naab, Thorsten; Choi, Ena; Ostriker, Jeremiah P.; Somerville, Rachel S.

    2017-12-01

    Galaxies occupy different regions of the [O III]λ5007/H β-versus-[N II]λ6584/H α emission-line ratio diagram in the distant and local Universe. We investigate the origin of this intriguing result by modelling self-consistently, for the first time, nebular emission from young stars, accreting black holes (BHs) and older, post-asymptotic giant branch (post-AGB) stellar populations in galaxy formation simulations in a full cosmological context. In post-processing, we couple new-generation nebular-emission models with high-resolution, cosmological zoom-in simulations of massive galaxies to explore which galaxy physical properties drive the redshift evolution of the optical-line ratios [O III]λ5007/H β, [N II]λ6584/H α, [S II]λλ6717, 6731/H α and [O I]λ6300/H α. The line ratios of simulated galaxies agree well with observations of both star-forming and active local Sloan Digital Sky Survey galaxies. Towards higher redshifts, at fixed galaxy stellar mass, the average [O III]/H β is predicted to increase and [N II]/H α, [S II]/H α and [O I]/H α to decrease - widely consistent with observations. At fixed stellar mass, we identify star formation history, which controls nebular emission from young stars via the ionization parameter, as the primary driver of the cosmic evolution of [O III]/H β and [N II]/H α. For [S II]/H α and [O I]/H α, this applies only to redshifts greater than z = 1.5, the evolution at lower redshift being driven in roughly equal parts by nebular emission from active galactic nuclei and post-AGB stellar populations. Instead, changes in the hardness of ionizing radiation, ionized-gas density, the prevalence of BH accretion relative to star formation and the dust-to-metal mass ratio (whose impact on the gas-phase N/O ratio we model at fixed O/H) play at most a minor role in the cosmic evolution of simulated galaxy line ratios.

  17. Fiber optical asssembly for fluorescence spectrometry

    Science.gov (United States)

    Piltch, Martin S.; Gray, Perry Clayton; Rubenstein, Richard

    2015-08-18

    System is provided for detecting the presence of an analyte of interest in a sample, said system comprising an elongated, transparent container for a sample; an excitation source in optical communication with the sample, wherein radiation from the excitation source is directed along the length of the sample, and wherein the radiation induces a signal which is emitted from the sample; and, at least two linear arrays disposed about the sample holder, each linear array comprising a plurality of optical fibers having a first end and a second end, wherein the first ends of the fibers are disposed along the length of the container and in proximity thereto; the second ends of the fibers of each array are bundled together to form a single end port.

  18. Proton Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrometry (AAS) applied in the environmental sample analysis

    International Nuclear Information System (INIS)

    Popescu, Ion V.; Iordan, M.; Stihi, C.; Bancuta, A.; Dima, G.; Busuioc, G.; Ciupina, V.; Belc, M.; Badica, T.

    2003-01-01

    The aim of this work is to determine the elemental composition of tree leaves using Proton-Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrophotometry (AAS) methods. By PIXE Spectrometry we identified and determined the concentration of S, Cl, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu Zn, As, Br, Sr and by AAS method the concentration of elements: Cr, Mn, Fe, Co, Cu, Zn, Se, Cd. Pb was identified in only 2 samples from 29. For tree leave samples collected at a large distance to the polluting source the Sr concentration decreased and the Mg, Ca, Se, Zn and Fe concentrations increased. Also, we can observe a small affinity of these leaves for the environmental Pb which was detected for two samples at a small distance to polluting source. (authors)

  19. Laser induced aluminiun plasma analysis by optical emission spectroscopy in a nitrogen background gas

    International Nuclear Information System (INIS)

    Chamorro, J C; Uzuriaga, J; Riascos, H

    2012-01-01

    We studied an Al plasma generated by a Nd:YAG laser with a laser fluence of 4 J/cm 2 , a wavelength of 1064 nm, energy pulse of 500 mJ and 10 Hz repetition rate. We studied their spectral characteristics at various ambient nitrogen pressures by optical emission spectroscopy (OES). The N 2 gas pressure was varied from 20 mTorr to 150 mTorr. In Al plume, both atomic and ionic spectra were observed. The electron temperature and electron number density of the plume as of the function ambient gas pressure were determined. The electron temperature was calculated by using the Boltzmann-plot method and the number density was calculated considering the stark effect as dominating on the emission lines.

  20. Application of optical emission spectroscopy to high current proton sources

    International Nuclear Information System (INIS)

    Castro, G; Mazzaglia, M; Nicolosi, D; Mascali, D; Reitano, R; Celona, L; Leonardi, O; Leone, F; Naselli, E; Neri, L; Torrisi, G; Gammino, S; Zaniol, B

    2017-01-01

    Optical Emission Spectroscopy (OES) represents a very reliable technique to carry out non-invasive measurements of plasma density and plasma temperature in the range of tens of eV. With respect to other diagnostics, it also can characterize the different populations of neutrals and ionized particles constituting the plasma. At INFN-LNS, OES techniques have been developed and applied to characterize the plasma generated by the Flexible Plasma Trap, an ion source used as 'testbench' of the proton source built for European Spallation Source. This work presents the characterization of the parameters of a hydrogen plasma in different conditions of neutral pressure, microwave power and magnetic field profile, along with perspectives for further upgrades of the OES diagnostics system. (paper)

  1. Determination of hafnium at the 10−4% level (relative to zirconium content) using neutron activation analysis, inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Smolik, Marek; Polkowska-Motrenko, Halina; Hubicki, Zbigniew; Jakóbik-Kolon, Agata; Danko, Bożena

    2014-01-01

    Graphical abstract: -- Highlights: •We worked out ICP-MS method of Hf determination in Zr and Zr compounds. •We used NAA method as reference one. •We obtained pure zirconium matrix by ion exchange (Diphonix ® resin). •These permit to determine ≥1 × 10 −4 % Hf in Zr sample by ICP MS with good precision and accuracy. -- Abstract: Hafnium at the very low level of 1–8 ppm (in relation to zirconium) was determined in zirconium sulfate solutions (originating from investigations of the separation of ca. 44 ppm Hf from zirconium by means of the ion exchange method) by using three independent methods: inductively coupled plasma mass spectrometry (ICP MS), neutron activation analysis (NAA) and inductively coupled plasma atomic emission spectrometry (ICP-AES). The results of NAA and ICP MS determinations were consistent with each other across the entire investigated range (the RSD of both methods did not exceed 38%). The results of ICP-AES determination were more diverse, particularly at less than 5 ppm Hf (RSD was significantly higher: 29–253%). The ion exchange method exploiting Diphonix ® resin proved sufficient efficiency in Zr–Hf separation when the initial concentration ratio of the elements ([Zr] 0 /[Hf] 0 ) ranged from 1200 to ca. 143,000

  2. Bidimensional characterization of the emission spectra in a direct current atmospheric pressure glow discharge

    International Nuclear Information System (INIS)

    Orejas, Jaime; Pisonero, Jorge; Bordel, Nerea; Nelis, Thomas; Guillot, Philippe; Sanz-Medel, Alfredo

    2012-01-01

    An in-house atmospheric pressure glow discharge source, designed to be used as ionization/desorption source for ambient mass spectrometry, has been electrically characterized, and its optical emission spectra evaluated in detail. Electrical characterization showed that the plasma regime can vary from glow discharge to arc discharge depending on operating conditions (i.e. He flow rate and inter electrode distance). Furthermore, bidimensional images of the optical emission of some plasma species using filters as wavelength selectors, were registered from inside and outside the discharge chamber (inner region and afterglow region respectively), showing the spatial distribution of excited species (i.e. He*, N 2 + and O*). These distribution patterns are useful to study the chemistry of the discharge plasma, since different production pathways and different excitation energies affect the presence of these species in the plasma regions. - Highlights: ► An in-house APGD is characterized through electrical and OES measurements. ► Interelectrode distance had more effect on electric regime than He flow rate. ► Internal plume images showed differences on the production pathways for each species. ► Higher interelectrode distances and He flow rates showed better afterglow conditions.

  3. A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties

    Science.gov (United States)

    Tao, Li; Daghighian, Henry M.; Levin, Craig S.

    2016-11-01

    Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the other hand, modulation mechanisms of the optical properties of a material exploited in the optical telecommunications industry can be orders of magnitude faster. In this paper we borrow from the concept of optics pump-probe measurement to for the first time study whether ionizing radiation can produce modulations of optical properties, which can be utilized as a novel method for radiation detection. We show that a refractive index modulation of approximately 5× {{10}-6} is induced by interactions in a cadmium telluride (CdTe) crystal from a 511 keV photon source. Furthermore, using additional radionuclide sources, we show that the amplitude of the optical modulation signal varies linearly with both the detected event rate and average photon energy of the radiation source.

  4. Fermi energy dependence of the optical emission in core/shell InAs nanowire homostructures

    Science.gov (United States)

    Möller, M.; Oliveira, D. S.; Sahoo, P. K.; Cotta, M. A.; Iikawa, F.; Motisuke, P.; Molina-Sánchez, A.; de Lima, M. M., Jr.; García-Cristóbal, A.; Cantarero, A.

    2017-07-01

    InAs nanowires grown by vapor-liquid-solid (VLS) method are investigated by photoluminescence. We observe that the Fermi energy of all samples is reduced by ˜20 meV when the size of the Au nanoparticle used for catalysis is increased from 5 to 20 nm. Additional capping with a thin InP shell enhances the optical emission and does not affect the Fermi energy. The unexpected behavior of the Fermi energy is attributed to the differences in the residual donor (likely carbon) incorporation in the axial (low) and lateral (high incorporation) growth in the VLS and vapor-solid (VS) methods, respectively. The different impurity incorporation rate in these two regions leads to a core/shell InAs homostructure. In this case, the minority carriers (holes) diffuse to the core due to the built-in electric field created by the radial impurity distribution. As a result, the optical emission is dominated by the core region rather than by the more heavily doped InAs shell. Thus, the photoluminescence spectra and the Fermi energy become sensitive to the core diameter. These results are corroborated by a theoretical model using a self-consistent method to calculate the radial carrier distribution and Fermi energy for distinct diameters of Au nanoparticles.

  5. Inductively coupled plasma--atomic emission spectrometry: trace elements in oil matrices

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Charlie Albert [Iowa State Univ., Ames, IA (United States)

    1977-12-01

    The simultaneous determination of up to 20 trace elements in various oil matrices by inductively coupled plasma-atomic emission spectrometry is reported. The oil matrices investigated were lubricating oils (for wear metals), fuel oil, centrifuged coal liquefaction product, crude soybean oil, and commercial edible oils. The samples were diluted with appropriate organic solvents and injected into the plasma as an aerosol generated by a pneumatic nebulization technique. Detection limits of the 28 elements studied ranged from 0.0006 to 9 μg/g with the majority falling in the 0.01 to 0.1 μg/g range. Analytical calibration curves were linear over at least two orders of magnitude and for some elements this linearity extended over 4.5 orders of magnitude. Relevant data on precision and accuracy are included. Because metals often occur as particles in lubricating oil and coal liquefaction products, the effect of particles on the analytical results was examined. Wear metal particles in used oil did not appear to affect the analytical results. However, incomplete recovery relative to organometallic reference solutions was obtained for iron particles with a nominal mean diameter of 3.0 μm suspended in oil. It was shown that the following factors contributed to incomplete recovery for the particles: settling of the suspended particles in the flask, a difference in nebulization efficiency between particle suspensions and organometallic solutions, and indications of incomplete vaporization of the larger particles in the plasma.

  6. Velocity-space sensitivity of neutron spectrometry measurements

    DEFF Research Database (Denmark)

    Jacobsen, Asger Schou; Salewski, Mirko; Eriksson, J.

    2015-01-01

    Neutron emission spectrometry (NES) measures the energies of neutrons produced in fusion reactions. Here we present velocity-space weight functions for NES and neutron yield measurements. Weight functions show the sensitivity as well as the accessible regions in velocity space for a given range...

  7. Chemical speciation of PM2.5 emissions from residential wood combustion and meat cooking

    International Nuclear Information System (INIS)

    McDonald, J.; Zielinska, B.; Fujita, E.; Chow, J.; Watson, J.; Sagebiel, J.; Sheetz, L.; Batie, S.

    1998-01-01

    Residential wood combustion and meat cooking emissions were each analyzed to develop a chemical emissions profile. Samples were collected using a DRI-constructed dilution stack sampler equipped with a 2.5 mm particle selective cyclone. Emissions were diluted 30-100 times, cooled to ambient temperature, and were allowed 80 seconds for condensation prior to collection. Fireplace and wood-stove emissions testing was conducted at the DRI facilities. Wood type, wood moisture, burn rate, and fuel load were varied for different experiments. Meat emissions testing was conducted at the CE-CERT stationary emissions lab in Riverside, California. Meat type, fat content, and the cooking appliance used were changed in different tests. Fine particle and semi-volatile organic compounds were collected on filter/PUF/XAD/PUF cartridges. Inorganic samples were collected on Teflon and quartz filters, which were analyzed for mass by gravimetry, elements by x-ray fluorescence, ammonium by automated colorimetry, organic and elemental carbon by thermal/optical reflectance, as well as chloride, nitrate, and sulfate by ion chromatography. Analysis of organic species was conducted by gas chromatography/mass spectrometry (GC/MS). These data have been utilized for constructing specific profiles for use in the Chemical Mass Balance model for apportionment of fine particle sources in the Denver, Colorado, region

  8. Gamma-emissions of some meteorites and terrestrial rocks. Evaluation of lunar soil radioactivity; Emissions gamma de quelques meteorites et roches terrestres. Evaluation de la radioactivite du sol lunaire

    Energy Technology Data Exchange (ETDEWEB)

    Nordemann, D. [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    The gamma-emissions of some terrestrial rocks and of the following meteorites: Bogou, Eagle-Station, Granes, and Dosso were studied by quantitative low background gamma spectrometry. These measurements and their interpretation lead to the evaluation of the possible gamma-emissions of several models of lunar soils. (author) [French] Les emissions gamma des meteorites Bogou, Eagle-Station, Granes et Dosso et de quelques roches terrestres ont ete etudiees par spectrometrie gamma quantitative a faible mouvement propre. Ces mesures et leur interpretation permettent d'evaluer les principales contributions des emissions gamma du sol lunaire pour des modeles de compositions possibles variees. (auteur)

  9. Gamma-emissions of some meteorites and terrestrial rocks. Evaluation of lunar soil radioactivity; Emissions gamma de quelques meteorites et roches terrestres. Evaluation de la radioactivite du sol lunaire

    Energy Technology Data Exchange (ETDEWEB)

    Nordemann, D [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    The gamma-emissions of some terrestrial rocks and of the following meteorites: Bogou, Eagle-Station, Granes, and Dosso were studied by quantitative low background gamma spectrometry. These measurements and their interpretation lead to the evaluation of the possible gamma-emissions of several models of lunar soils. (author) [French] Les emissions gamma des meteorites Bogou, Eagle-Station, Granes et Dosso et de quelques roches terrestres ont ete etudiees par spectrometrie gamma quantitative a faible mouvement propre. Ces mesures et leur interpretation permettent d'evaluer les principales contributions des emissions gamma du sol lunaire pour des modeles de compositions possibles variees. (auteur)

  10. Spatial organization of lipids in the human retina and optic nerve by MALDI imaging mass spectrometry.

    Science.gov (United States)

    Zemski Berry, Karin A; Gordon, William C; Murphy, Robert C; Bazan, Nicolas G

    2014-03-01

    MALDI imaging mass spectrometry (IMS) was used to characterize lipid species within sections of human eyes. Common phospholipids that are abundant in most tissues were not highly localized and observed throughout the accessory tissue, optic nerve, and retina. Triacylglycerols were highly localized in accessory tissue, whereas sulfatide and plasmalogen glycerophosphoethanolamine (PE) lipids with a monounsaturated fatty acid were found enriched in the optic nerve. Additionally, several lipids were associated solely with the inner retina, photoreceptors, or retinal pigment epithelium (RPE); a plasmalogen PE lipid containing DHA (22:6), PE(P-18:0/22:6), was present exclusively in the inner retina, and DHA-containing glycerophosphatidylcholine (PC) and PE lipids were found solely in photoreceptors. PC lipids containing very long chain (VLC)-PUFAs were detected in photoreceptors despite their low abundance in the retina. Ceramide lipids and the bis-retinoid, N-retinylidene-N-retinylethanolamine, was tentatively identified and found only in the RPE. This MALDI IMS study readily revealed the location of many lipids that have been associated with degenerative retinal diseases. Complex lipid localization within retinal tissue provides a global view of lipid organization and initial evidence for specific functions in localized regions, offering opportunities to assess their significance in retinal diseases, such as macular degeneration, where lipids have been implicated in the disease process.

  11. Interpretation of the electron cyclotron emission of hot ASDEX upgrade plasmas at optically thin frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Denk, Severin Sebastian; Stroth, Ulrich [Max-Planck-Institut fuer Plasmaphysik, D-85748 Garching (Germany); Physik-Department E28, Technische Universitaet Muenchen, 85748 Garching (Germany); Fischer, Rainer; Poli, Emanuele; Willensdorfer, Matthias; Maj, Omar; Stober, Joerg; Suttrop, Wolfgang [Max-Planck-Institut fuer Plasmaphysik, D-85748 Garching (Germany); Collaboration: The ASDEX Upgrade Team

    2016-07-01

    The electron cyclotron emission diagnostic (ECE) provides routinely electron temperature (T{sub e}) measurements. ''Kinetic effects'' (relativistic mass shift and Doppler shift) can cause the measured radiation temperatures (T{sub rad}) to differ from T{sub e} at cold resonance position complicating the determination of T{sub e} from the measured radiation temperature profile (T{sub rad}). For the interpretation of such ECE measurements an electron cyclotron forward model solving the radiation transport equation for given T{sub e} and electron density profiles is in use in the framework of Integrated Data Analysis at ASDEX Upgrade. While the original model lead to improved T{sub e} profiles near the plasma edge in moderately hot H-mode discharges, vacuum approximations in the model lead to inaccuracies given large T{sub e}. In hot plasmas ''wave-plasma interaction'', i.e. the dielectric effect of the background plasma onto the electron cyclotron emission, becomes important at optical thin measured frequencies. Additionally, given moderate electron densities and large T{sub e}, the refraction of the line of sight has to be considered for the interpretation of ECE measurements with low optical depth.

  12. Process control of high rate microcrystalline silicon based solar cell deposition by optical emission spectroscopy

    International Nuclear Information System (INIS)

    Kilper, T.; Donker, M.N. van den; Carius, R.; Rech, B.; Braeuer, G.; Repmann, T.

    2008-01-01

    Silicon thin-film solar cells based on microcrystalline silicon (μc-Si:H) were prepared in a 30 x 30 cm 2 plasma-enhanced chemical vapor deposition reactor using 13.56 or 40.68 MHz plasma excitation frequency. Plasma emission was recorded by optical emission spectroscopy during μc-Si:H absorber layer deposition at deposition rates between 0.5 and 2.5 nm/s. The time course of SiH * and H β emission indicated strong drifts in the process conditions particularly at low total gas flows. By actively controlling the SiH 4 gas flow, the observed process drifts were successfully suppressed resulting in a more homogeneous i-layer crystallinity along the growth direction. In a deposition regime with efficient usage of the process gas, the μc-Si:H solar cell efficiency was enhanced from 7.9 % up to 8.8 % by applying process control

  13. In-situ virtual metrology for the silicon-dioxide etch rate by using optical emission spectroscopy data

    International Nuclear Information System (INIS)

    Kim, Boomsoo; Hong, Sangjeen

    2014-01-01

    As a useful tool for process control in a high volume semiconductor manufacturing environment, virtual metrology for the etch rate in a plasma etch process is investigated using optical emission spectroscopy (OES) data. Virtual metrology is a surrogate measurement taken from the process instead of from direct measurement, and it can provide in-situ metrology of a wafer's geometry from a predictive model. A statistical regression model that correlates the selected wavelengths of the optical emission spectra to the etch rate is established using the OES data collected over 20 experimental runs. In addition, an argon actinometry study is employed to quantify the OES data, and it provides valuable insight into the analysis of the OES data. The established virtual metrology model is further verified with an additional 20 runs of data. As a result, the virtual metrology model with both process recipe tool data and in-situ data shows higher prediction accuracy by as much as 56% compared with either the process recipe tool data or the in-situ data alone.

  14. Profiling an electrospray plume by laser-induced fluorescence and Fraunhofer diffraction combined to mass spectrometry: influence of size and composition of droplets on charge-state distributions of electrosprayed proteins.

    Science.gov (United States)

    Girod, Marion; Dagany, Xavier; Boutou, Véronique; Broyer, Michel; Antoine, Rodolphe; Dugourd, Philippe; Mordehai, Alex; Love, Craig; Werlich, Mark; Fjeldsted, John; Stafford, George

    2012-07-14

    We investigated how physico-chemical properties of charged droplets are affected by the electrospray process, using simultaneous in situ measurements by laser-induced fluorescence (LIF), Fraunhofer diffraction and mass spectrometry. For this purpose, we implemented a laser-induced-fluorescence profiling setup in conjunction with a fast, high-resolution particle sizing scheme on a modified Agilent Jet Stream electrospray source coupled to a single quadrupole mass analyser. The optical setup permits us to profile the solvent fractionation and the size of the droplets as they evaporate in an electrospray plume by measuring both the angular scattering pattern and emission spectra of a solvatochromic fluorescent dye. Mass spectra are recorded simultaneously. These mass spectrometry and optical spectroscopy investigations allow us to study the relation between the observed charge-state distributions of protein anions and physico-chemical properties of evaporating droplets in the spray plume. By mixing water with methanol, a refolding of cytochrome C is observed as the water percentage increases in the plume due to the preponderant evaporation of volatile methanol.

  15. Spectral evolution of soft x-ray emission from optically thin, high electron temperature platinum plasmas

    Directory of Open Access Journals (Sweden)

    Hiroyuki Hara

    2017-08-01

    Full Text Available The soft x-ray spectra of heavy element plasmas are frequently dominated by unresolved transition array (UTA emission. We describe the spectral evolution of an intense UTA under optically thin conditions in platinum plasmas. The UTA was observed to have a peak wavelength around 4.6 nm at line-of-sight averaged electron temperatures less than 1.4 keV at electron densities of (2.5–7.5 × 1013 cm−3. The UTA spectral structure was due to emission from 4d–4f transitions in highly charged ions with average charge states of q = 20–40. A numerical simulation successfully reproduced the observed spectral behavior.

  16. Plant trait detection with multi-scale spectrometry

    Science.gov (United States)

    Gamon, J. A.; Wang, R.

    2017-12-01

    Proximal and remote sensing using imaging spectrometry offers new opportunities for detecting plant traits, with benefits for phenotyping, productivity estimation, stress detection, and biodiversity studies. Using proximal and airborne spectrometry, we evaluated variation in plant optical properties at various spatial and spectral scales with the goal of identifying optimal scales for distinguishing plant traits related to photosynthetic function. Using directed approaches based on physiological vegetation indices, and statistical approaches based on spectral information content, we explored alternate ways of distinguishing plant traits with imaging spectrometry. With both leaf traits and canopy structure contributing to the signals, results exhibit a strong scale dependence. Our results demonstrate the benefits of multi-scale experimental approaches within a clear conceptual framework when applying remote sensing methods to plant trait detection for phenotyping, productivity, and biodiversity studies.

  17. Synthesis, field emission properties and optical properties of ZnSe nanoflowers

    Energy Technology Data Exchange (ETDEWEB)

    Xue, S.L., E-mail: slxue@dhu.edu.cn [Department of Applied Physics, College of Science, Donghua University, Shanghai 201620 (China); Wu, S.X.; Zeng, Q.Z.; Xie, P.; Gan, K.X.; Wei, J.; Bu, S.Y.; Ye, X.N.; Xie, L. [Department of Applied Physics, College of Science, Donghua University, Shanghai 201620 (China); Zou, R.J. [State Key Laboratory for Modification and Chemical Fibers and Polymer Materials, Donghua University, Shanghai 201620 (China); Zhang, C.M.; Zhu, P.F. [Department of Physics, School of Fundamental Studies, Shanghai University of Engineering Science, Shanghai 201620 (China)

    2016-03-01

    Graphical abstract: Unique ZnSe nanoflowers have been successfully synthesized by reaction of Se powder with Zn substrates. They are characterized by XRD, SEM, TEM, XPS, EDS and Raman spectroscopy and were single crystals with cubic zinc blende (ZB) structure. They also have excellent field emission properties and optical properties. - Highlights: • Novel ZnSe nanoflowers are grown on Zn foils. • ZnSe nanoflowers are characterized by XRD, SEM, TEM, XPS and Raman spectra. • ZnSe nanoflowers on Zn foils as cathodes possess good FE properties. - Abstract: ZnSe nanoflowers have been synthesized by reaction of Se powder with Zn substrates at low temperature. The as-prepared ZnSe nanoflowers were characterized by X-ray diffraction (XRD), scanning electron microscope (SEM), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), X-ray photoelectron spectroscopy (XPS), X-ray energy dispersive spectroscope (EDS) and Raman spectroscopy measurements. It was found that the morphologies of the as-prepared samples highly depended on reaction time. ZnSe nanoclusters and nanoflowers formed at 573 K when the reaction time was 20 and 60 min, respectively. The as-prepared ZnSe nanoflowers were composed of radically aligned ZnSe nanorods with smooth surfaces. The results of XRD, XPS, EDS, TEM and Raman showed that the as-prepared ZnSe nanocrystals were single crystals with cubic zinc blende (ZB) structure. The formation mechanism of the as-prepared ZnSe nanoflowers was also discussed. In addition, the as-prepared ZnSe nanoflowers had excellent electron emission properties. The turn-on field of the as-prepared ZnSe nanoflowers was 3.5 V/μm and the enhancement factor was 3499. The optical properties of the as-prepared ZnSe nanoflowers were also investigated. The results demonstrated that the as-prepared ZnSe nanoflowers were potential candidates for optoelectronic devices.

  18. Use of gradient dilution to flag and overcome matrix interferences in axial-viewing inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Cheung, Yan; Schwartz, Andrew J.; Hieftje, Gary M.

    2014-01-01

    Despite the undisputed power of inductively coupled plasma-atomic emission spectrometry (ICP-AES), its users still face serious challenges in obtaining accurate analytical results. Matrix interference is perhaps the most important challenge. Dilution of a matrix-containing sample is a common practice to reduce matrix interference. However, determining the optimal dilution factor requires tedious and time-consuming offline sample preparation, since emission lines and the effect of matrix interferences are affected differently by the dilution. The current study exploits this difference by employing a high-performance liquid chromatography gradient pump prior to the nebulizer to perform on-line mixing of a sample solution and diluent. Linear gradient dilution is performed on both the calibration standard and the matrix-containing sample. By ratioing the signals from two emission lines (from the same or different elements) as a function of dilution factor, the analyst can not only identify the presence of a matrix interference, but also determine the optimal dilution factor needed to overcome the interference. A ratio that does not change with dilution signals the absence of a matrix interference, whereas a changing ratio indicates the presence of an interference. The point on the dilution profile where the ratio stabilizes indicates the optimal dilution factor to correct the interference. The current study was performed on axial-viewing ICP-AES with o-xylene as the solvent

  19. Simultaneous determination of Cr, Ga, In and V in soil and water samples by tungsten coil atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Donati, George L.; Kron, Benjamin E. [Department of Chemistry, Wake Forest University, Winston-Salem, NC 27109 (United States); Jones, Bradley T. [Department of Chemistry, Wake Forest University, Winston-Salem, NC 27109 (United States)], E-mail: jonesbt@wfu.edu

    2009-06-15

    Tungsten coil atomic emission spectrometry is employed for the simultaneous determination of Cr, Ga, In, and V. Both V and In are detected by this technique for the first time. The atomizer is a simple, inexpensive tungsten filament extracted from a mass-produced, commercially-available 150 W, 15 V microscope bulb. A 25 {mu}l sample aliquot is placed directly on the coil and a small constant-current power source is used to carefully dry, ash and atomize the sample. Analytical signals are detected with a Czerny-Turner spectrograph and a charge coupled device detector. Multiple emission lines from all 4 elements are monitored simultaneously in a 54 nm spectral window. Concentration limits of detection are in the {mu}g l{sup - 1} range for all elements, and the absolute limits of detection are 0.2, 2, 0.5, and 10 ng for Cr, Ga, In, and V, respectively. Even lower values may be obtained by combining the signals for the multiple emission lines of a single element. The method precision is typically better than 5.0% relative standard deviation, and sometimes as good as 0.95% (Ga). Standard reference materials of soil and water are used to check the method accuracy. After a simple acid extraction, the values determined by the method presented no significant difference from the reported values at the 95% confidence level.

  20. Multipoint dynamically reconfigure adaptive distributed fiber optic acoustic emission sensor (FAESense) system for condition based maintenance

    Science.gov (United States)

    Mendoza, Edgar; Prohaska, John; Kempen, Connie; Esterkin, Yan; Sun, Sunjian; Krishnaswamy, Sridhar

    2010-09-01

    This paper describes preliminary results obtained under a Navy SBIR contract by Redondo Optics Inc. (ROI), in collaboration with Northwestern University towards the development and demonstration of a next generation, stand-alone and fully integrated, dynamically reconfigurable, adaptive fiber optic acoustic emission sensor (FAESense™) system for the in-situ unattended detection and localization of shock events, impact damage, cracks, voids, and delaminations in new and aging critical infrastructures found in ships, submarines, aircraft, and in next generation weapon systems. ROI's FAESense™ system is based on the integration of proven state-of-the-art technologies: 1) distributed array of in-line fiber Bragg gratings (FBGs) sensors sensitive to strain, vibration, and acoustic emissions, 2) adaptive spectral demodulation of FBG sensor dynamic signals using two-wave mixing interferometry on photorefractive semiconductors, and 3) integration of all the sensor system passive and active optoelectronic components within a 0.5-cm x 1-cm photonic integrated circuit microchip. The adaptive TWM demodulation methodology allows the measurement of dynamic high frequnency acoustic emission events, while compensating for passive quasi-static strain and temperature drifts. It features a compact, low power, environmentally robust 1-inch x 1-inch x 4-inch small form factor (SFF) package with no moving parts. The FAESense™ interrogation system is microprocessor-controlled using high data rate signal processing electronics for the FBG sensors calibration, temperature compensation and the detection and analysis of acoustic emission signals. Its miniaturized package, low power operation, state-of-the-art data communications, and low cost makes it a very attractive solution for a large number of applications in naval and maritime industries, aerospace, civil structures, the oil and chemical industry, and for homeland security applications.

  1. Optical emission spectrographic analysis of lutetium oxide for rare earth impurities

    International Nuclear Information System (INIS)

    Chandola, L.C.; Dixit, V.S.

    1986-01-01

    An optical emission spectrographic (OES) method has been developed for the analysis of high purity lutetium oxide to determine rare earths Er, Tm, Yb and Y. The spectra are excited by a d.c. arc run at 10 A current after mixing the sample with graphite buffer in the weight ratio 1:1. A 1200 grooves/mm grating blazed at 3300 A is used for dispersion and a Kodak SA-1 plate for recording the spectrum. The detection limit is 0.001 per cent for Tm, Yb and Y while it is 0.005 per cent for Er. The relative standard deviation of the method is ± 13.4 per cent. (author)

  2. Relating Line Width and Optical Depth for CO Emission in the Large Mgellanic Cloud

    Science.gov (United States)

    Wojciechowski, Evan; Wong, Tony; Bandurski, Jeffrey; MC3 (Mapping CO in Molecular Clouds in the Magellanic Clouds) Team

    2018-01-01

    We investigate data produced from ALMA observations of giant molecular clouds (GMCs) located in the Large Magellanic Cloud (LMC), using 12CO(2–1) and 13CO(2–1) emission. The spectral line width is generally interpreted as tracing turbulent rather than thermal motions in the cloud, but could also be affected by optical depth, especially for the 12CO line (Hacar et al. 2016). We compare the spectral line widths of both lines with their optical depths, estimated from an LTE analysis, to evaluate the importance of optical depth effects. Our cloud sample includes two regions recently published by Wong et al. (2017, submitted): the Tarantula Nebula or 30 Dor, an HII region rife with turbulence, and the Planck cold cloud (PCC), located in a much calmer environment near the fringes of the LMC. We also include four additional LMC clouds, which span intermediate levels of star formation relative to these two clouds, and for which we have recently obtained ALMA data in Cycle 4.

  3. Amplified spontaneous emission spectrum and gain characteristic of a two-electrode semiconductor optical amplifier

    International Nuclear Information System (INIS)

    Wang Hanchao; Huang Lirong; Shi Zhongwei

    2011-01-01

    A two-electrode multi-quantum-well semiconductor optical amplifier is designed and fabricated. The amplified spontaneous emission (ASE) spectrum and gain were measured and analyzed. It is shown that the ASE spectrum and gain characteristic are greatly influencedby the distribution of the injection current density. By changing the injection current density of two electrodes, the full width at half maximum, peak wavelength, peak power of the ASE spectrum and the gain characteristic can be easily controlled. (semiconductor devices)

  4. Red sprites and blue jets: Thunderstorm-excited optical emissions in the stratosphere, mesosphere, and ionosphere

    International Nuclear Information System (INIS)

    Sentman, D.D.; Wescott, E.M.

    1995-01-01

    Recent low light level monochrome television observations obtained from the ground and from the space shuttle, and low light level color and monochrome television images obtained from aboard jet aircraft, have shown that intense lightning in mesoscale thunderstorm systems may excite at least two distinct types of optical emissions that together span the space between the tops of some thunderstorms and the ionosphere. The first of these emissions, dubbed ''sprites,'' are luminous red structures that typically span the altitude range 60--90 km, often with faint bluish tendrils dangling below. A second, rarer, type of luminous emission are ''blue jets'' that appear to spurt upward out of the anvil top in narrow cones to altitudes of 40--50 km at speeds of ∼100 km/s. In this paper the principal observational characteristics of sprites and jets are presented, and several proposed production mechanisms are reviewed. copyright 1995 American Institute of Physics

  5. Effect of the three-dimensional structure of laser emission on the dynamics of low-threshold optical breakdown plasmas

    Science.gov (United States)

    Anisimov, V. N.; Arutiunian, R. V.; Bol'Shov, L. A.; Derkach, O. N.; Kanevskii, M. F.

    1989-03-01

    The effect of the transverse structure of pulsed CO2 laser emission on the dynamics of laser-induced detonation waves propagating from a metal surface and on plasma transparency recovery is investigated theoretically and experimentally. Particular attention is given to breakdown initiation near the surface. It is suggested that the inclusion of refraction in the plasma into a self-consistent numerical mode is essential for the adequate quantitative description of experimental data on the interaction of laser emission with low-threshold optical breakdown plasmas.

  6. In situ optical emission study on the role of C2 in the synthesis of singlewalled carbon nanotubes

    CSIR Research Space (South Africa)

    Motaung, DE

    2010-01-01

    Full Text Available applications. In this study, the authors have applied in situ optical emission spectroscopy (OES) to study the plasma in the laser-furnace method to synthesize SWCNTs. In particular, the authors have investigated the temporal and spatial behavior of C2 as well...

  7. Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Yim, Yong Hyeon; Park, Ji Youn; Han, Myung Sub; Park, Mi Kyung; Kim, Byung Joo; Lim, Young Ran; Hwang, Eui Jin; So, Hun Young

    2005-01-01

    A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties

  8. Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Yong Hyeon; Park, Ji Youn; Han, Myung Sub; Park, Mi Kyung; Kim, Byung Joo; Lim, Young Ran; Hwang, Eui Jin; So, Hun Young [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2005-03-15

    A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties.

  9. Determination of trace elements in paints by direct sampling graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bentlin, Fabrina R.S. [Instituto de Quimica, Universidade Federal do Rio Grande do Sul, UFRGS, 91501-970 Porto Alegre, RS (Brazil); Pozebon, Dirce [Instituto de Quimica, Universidade Federal do Rio Grande do Sul, UFRGS, 91501-970 Porto Alegre, RS (Brazil)], E-mail: dircepoz@iq.ufrgs.br; Mello, Paola A.; Flores, Erico M.M. [Departamento de Quimica, Universidade Federal de Santa Maria, UFSM, 97105-900 Santa Maria, RS (Brazil)

    2007-10-17

    A direct sampling graphite furnace atomic absorption spectrometric (DS-GFAAS) method for the determination of Cd, Pb, Cr, Ni, Co and Cu in paints has been developed. Serigraphy, acrylic and tattoo paints were analysed. Approaches like pyrolysis and atomization temperatures, modifiers and sample mass introduced in the atomizer were studied. Quantification was performed using calibration curves measured with aqueous standard solutions pipetted onto the platform. The sample mass introduced in the graphite tube ranged from 0.02 to 8.0 mg. Palladium was used as modifier for Cd, Pb and Cu, while Mg(NO{sub 3}){sub 2} was used for Co. For Ni determination, the graphite platform was covered with carbon powder. The characteristic masses of Cd, Pb, Cr, Ni, Co and Cu were 1.4, 22.5, 7.9, 11.0, 9.6 and 12.5 pg, while the limits of detection were 0.0004, 0.001, 0.03, 0.22, 0.11 and 0.05 {mu}g g{sup -1} of Cd, Pb, Cr, Ni, Co and Cu, respectively. The accuracy was determined by comparison of the results with those obtained by inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GFAAS), using liquid sampling of digests. For matrix characterization, major and minor elements (Al, Mg, Ba, Ca, Cr, Cu, Pb, Sr, Ti and Mg) were determined by inductively coupled plasma optical emission spectrometry (ICP OES)

  10. Determination of uranium in seawater by fluorescence spectrometry

    International Nuclear Information System (INIS)

    Kawashima, Toshi; Kawakubo, Senkichi; Minegishi, Hisako.

    1984-01-01

    A Fluorescence spectrometry for the determination of uranium in seawater has been developed. Anion exchange separation of uranium from seawater followed by preparation of NaF-carbonate cake and by spectrometry for ultraviolet ray excited fluorescence of uranium on the fluoride host provide the trace determinaton of uranium at the subnano gram level. Anion exchange behavior, excitation-emission behavior of the uranium on the host and effects of foreign ions to the fluorescence have been presented. Appling the method to 1 ml of seawater 3 ppb of uranium has been determined. (author)

  11. Stunningly bright optical emission

    Science.gov (United States)

    Heinke, Craig O.

    2017-12-01

    The detection of bright, rapid optical pulsations from pulsar PSR J1023+0038 have provided a surprise for researchers working on neutron stars. This discovery poses more questions than it answers and will spur on future work and instrumentation.

  12. Optical emission spectroscopic study of Ar/H2/CH4 plasma during the production of graphene nano-flakes by induction plasma synthesis

    International Nuclear Information System (INIS)

    Mohanta, Antaryami; Lanfant, Briac; Asfaha, Mehari; Leparoux, Marc

    2017-01-01

    Graphene nano-flakes using CH 4 precursor were synthesized in a radio frequency inductively coupled plasma reactor with in-situ investigation of Ar/H 2 /CH 4 plasma by optical emission spectroscopy at fixed H 2 and Ar flow rates of 4 and 75 slpm, respectively, and at different plate powers (12 to 18 kW), pressures (400 to 700 mbar) and CH 4 flow rates (0.3 to 2 slpm). Emissions from C 2 Swan band, C 3 , CH and H 2 are observed in the optical emission spectra of Ar/H 2 /CH 4 plasma. Plasma temperature estimated analyzing the C 2 Swan band emission intensities is found to be decreased with increasing pressure and decreasing plate power. The decreasing plasma temperature gives rise to increase in production rate due to increase in condensation process. The production rate is observed to be increased from 0 to 0.3 g/h at 18 kW and from 0 to 1 g/h at 15 kW with increase in pressure from 400 to 700 mbar at fixed CH 4 flow rate of 0.7 slpm. Broad band continuum emission appears in the emission spectra at specific growth conditions in which the formation of vapor phase nanoparticles due to condensation of supersaturated vapor is facilitated. The production rate at 12 kW, 700 mbar, and 0.7 slpm of CH 4 flow rate is found to be 1.7 g/h which is more than that at 15 and 18 kW. Thus, the broadband continuum emission dominates the optical emission spectra at 12 kW due to lower temperature and higher production rate, and is attributed to the emission from suspended nanoparticles formed in vapor phase. The synthesized nanoparticles exhibit flake like structures having average length and width about 200 and 100 nm, respectively, irrespective of the growth conditions. Nano-flakes have thickness between 3.7 to 7.5 nm and are composed of 11 to 22 graphene layers depending on the growth conditions. The intensity ratio (I D /I G ) of D and G band observed in the Raman spectra is less than 0.33 which indicates good quality of the synthesized graphene nano-flakes. (paper)

  13. Analysis of non-regulated vehicular emissions by extractive FTIR spectrometry: tests on a hybrid car in Mexico City

    Science.gov (United States)

    Reyes, F.; Grutter, M.; Jazcilevich, A.; González-Oropeza, R.

    2006-07-01

    A methodology to acquire valuable information on the chemical composition and evolution of vehicular emissions is presented. The analysis of the gases is performed by passing a constant flow of a sample gas from the tail-pipe into a 10 L multi-pass cell. The absorption spectra within the cell are obtained using an FTIR spectrometer at 0.5 cm-1 resolution along a 13.1 m optical path. Additionally, the total flow from the exhaust is continuously measured from a differential pressure sensor on a Pitot tube installed at the exit of the exhaust. This configuration aims to obtain a good speciation capability by coadding spectra during 30 s and reporting the emission (in g/km) of key and non-regulated pollutants, such as CO2, CO, NO, SO2, NH3, HCHO, NMHC, during predetermined driving routines. The advantages and disadvantages of increasing the acquisition frequency, as well as the effect of other parameters such as spectral resolution, cell volume and flow rate, are discussed. With the aim of testing and evaluating the proposed technique, experiments were performed on a dynamometer running FTP-75 and typical driving cycles of the Mexico City Metropolitan Area (MCMA) on a Toyota Prius hybrid vehicle. This car is an example of recent automotive technology to reach the market dedicated to reduce emissions and therefore pressing the need of low detection techniques. This study shows the potential of the proposed technique to measure and report in real time the emissions of a large variety of pollutants, even from a super ultra-low emission vehicle (SULEV). The emissions of HC's, NOx, CO and CO2 obtained here are similar to experiments performed in other locations with the same vehicle model. Some differences suggest that an inefficient combustion process and type of gasoline used in the MCMA may be partly responsible for lower CO2 and higher CO and NO emission factors. Also, a fast reduction of NO emission to very low values is observed after cold ignition, giving rise to

  14. Effect and control on temperature measurement accuracy of the fiber- optic colorimeter by emissivity of different temperatures

    Science.gov (United States)

    Liu, Yu-fang; Han, Xin; Shi, De-heng

    2008-03-01

    Based on the Kirchhoff's Law, a practical dual-wavelength fiber-optic colorimeter, with the optimal work wavelength centered at 2.1 μm and 2.3 μm is presented. The effect of the emissivity on the precision of the measured temperature has been explored under various circumstances (i.e. temperature, wavelength) and for different materials. In addition, by fitting several typical material emissivity-temperature dependencies curves, the influence of the irradiation (radiant flux originating from the surroundings) and the surface reflected radiation on the temperature accuracy is studied. The results show that the calibration of the measured temperature for reflected radiant energy is necessary especially in low target temperature or low target emissivity, and the temperature accuracy is suitable for requirements in the range of 400-1200K.

  15. Emission characteristics of the Yb3+-sensitized Tm3+-doped optical fiber upon pumping with infrared LED

    International Nuclear Information System (INIS)

    Htein, Lin; Fan, Weiwei; Han, Won-Taek

    2014-01-01

    Near infrared emissions at 975, 1040 and 1450 nm of the Yb 3+ -sensitized Tm 3+ -doped optical fiber were obtained upon simultaneous excitation of Yb 3+ and Tm 3+ ions using the infrared LED. -- Highlights: • A novel pumping scheme for 1450 nm emission from 3 H 4 → 3 F 4 transition of Tm was demonstrated. • The absorption bands of Yb and Tm located within 690–970 nm were simultaneously excited with the IR LED. • Near infrared emissions at 975, 1040 and 1450 nm were obtained. • The Yb 3+ /Tm 3+ -codoped fiber showed the good spectroscopic quality and the increase of radiative lifetime of 3 H 4 level. • This LED pumping scheme can be useful for low-cost S-band fiber laser/amplifier applications

  16. Optical Emission Spectroscopy of an Atmospheric Pressure Plasma Jet During Tooth Bleaching Gel Treatment.

    Science.gov (United States)

    Šantak, Vedran; Zaplotnik, Rok; Tarle, Zrinka; Milošević, Slobodan

    2015-11-01

    Optical emission spectroscopy was performed during atmospheric pressure plasma needle helium jet treatment of various tooth-bleaching gels. When the gel sample was inserted under the plasma plume, the intensity of all the spectral features increased approximately two times near the plasma needle tip and up to two orders of magnitude near the sample surface. The color change of the hydroxylapatite pastille treated with bleaching gels in conjunction with the atmospheric pressure plasma jet was found to be in correlation with the intensity of OH emission band (309 nm). Using argon as an additive to helium flow (2 L/min), a linear increase (up to four times) of OH intensity and, consequently, whitening (up to 10%) of the pastilles was achieved. An atmospheric pressure plasma jet activates bleaching gel, accelerates OH production, and accelerates tooth bleaching (up to six times faster).

  17. Dynamics, OH distributions and UV emission of a gliding arc at various flow-rates investigated by optical measurements

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Sun, Zhiwei; Li, Zhongshan

    2014-01-01

    -state OH were investigated using planar laser-induced fluorescence. The results show that the shape, height, intensity and thickness of ground-state OH distribution vary significantly with air flow rates. Finally, UV emission of the gliding arc is measured using optical emission spectroscopy......We demonstrate a plasma discharge which is generated between two diverging electrodes and extended into a gliding arc in non-equilibrium condition by an air flow at atmospheric pressure. Effects of the air flow rates on the dynamics, ground-state OH distributions and spectral characterization of UV...

  18. Tunable electronic, electrical and optical properties of graphene oxide sheets by ion irradiation

    Science.gov (United States)

    Jayalakshmi, G.; Saravanan, K.; Panigrahi, B. K.; Sundaravel, B.; Gupta, Mukul

    2018-05-01

    The tunable electronic, electrical and optical properties of graphene oxide (GO) sheets were investigated using a controlled reduction by 500 keV Ar+-ion irradiation. The carbon to oxygen ratio of the GO sheets upon the ion beam reduction has been estimated using resonant Rutherford backscattering spectrometry analyses and its effect on the electrical and optical properties of GO sheets has been studied using sheet resistance measurements and photoluminescence (PL) measurements. The restoration of sp 2-hybridized carbon atoms within the sp 3 matrix is found to be increases with increasing the Ar+-ion fluences as evident from Fourier transform infrared, and x-ray absorption near-edge structure measurements. The decrease in the number of disorder-induced local density of states (LDOSs) within the π-π* gap upon the reduction causes the shifting of PL emission from near infra-red to blue region and decreases the sheet resistance. The improved electrical and optical properties of GO sheets were correlated to the decrease in the number of LDOSs within the π-π* gap. Our experimental investigations suggest ion beam irradiation is one of an effective approaches to reduce GO to RGO and to tailor its electronic, electrical and optical properties.

  19. Plasma diagnostics during magnetron sputtering of aluminum doped zinc oxide

    DEFF Research Database (Denmark)

    Stamate, Eugen; Crovetto, Andrea; Sanna, Simone

    2016-01-01

    Plasma parameters during magnetron sputtering of aluminum-doped zinc oxide are investigated with optical emission spectroscopy, electrostatic probes and mass spectrometry with the aim of understanding the role of negative ions of oxygen during the film growth and improving the uniformity of the f......Plasma parameters during magnetron sputtering of aluminum-doped zinc oxide are investigated with optical emission spectroscopy, electrostatic probes and mass spectrometry with the aim of understanding the role of negative ions of oxygen during the film growth and improving the uniformity...

  20. Acoustic emission detection with fiber optical sensors for dry cask storage health monitoring

    Science.gov (United States)

    Lin, Bin; Bao, Jingjing; Yu, Lingyu; Giurgiutiu, Victor

    2016-04-01

    The increasing number, size, and complexity of nuclear facilities deployed worldwide are increasing the need to maintain readiness and develop innovative sensing materials to monitor important to safety structures (ITS). In the past two decades, an extensive sensor technology development has been used for structural health monitoring (SHM). Technologies for the diagnosis and prognosis of a nuclear system, such as dry cask storage system (DCSS), can improve verification of the health of the structure that can eventually reduce the likelihood of inadvertently failure of a component. Fiber optical sensors have emerged as one of the major SHM technologies developed particularly for temperature and strain measurements. This paper presents the development of optical equipment that is suitable for ultrasonic guided wave detection for active SHM in the MHz range. An experimental study of using fiber Bragg grating (FBG) as acoustic emission (AE) sensors was performed on steel blocks. FBG have the advantage of being durable, lightweight, and easily embeddable into composite structures as well as being immune to electromagnetic interference and optically multiplexed. The temperature effect on the FBG sensors was also studied. A multi-channel FBG system was developed and compared with piezoelectric based AE system. The paper ends with conclusions and suggestions for further work.

  1. Characterizing Methane Emissions at Local Scales with a 20 Year Total Hydrocarbon Time Series, Imaging Spectrometry, and Web Facilitated Analysis

    Science.gov (United States)

    Bradley, Eliza Swan

    Methane is an important greenhouse gas for which uncertainty in local emission strengths necessitates improved source characterizations. Although CH4 plume mapping did not motivate the NASA Airborne Visible InfraRed Imaging Spectrometer (AVIRIS) design and municipal air quality monitoring stations were not intended for studying marine geological seepage, these assets have capabilities that can make them viable for studying concentrated (high flux, highly heterogeneous) CH4 sources, such as the Coal Oil Point (COP) seep field (˜0.015 Tg CH4 yr-1) offshore Santa Barbara, California. Hourly total hydrocarbon (THC) data, spanning 1990 to 2008 from an air pollution station located near COP, were analyzed and showed geologic CH4 emissions as the dominant local source. A band ratio approach was developed and applied to high glint AVIRIS data over COP, resulting in local-scale mapping of natural atmospheric CH4 plumes. A Cluster-Tuned Matched Filter (CTMF) technique was applied to Gulf of Mexico AVIRIS data to detect CH4 venting from offshore platforms. Review of 744 platform-centered CTMF subsets was facilitated through a flexible PHP-based web portal. This dissertation demonstrates the value of investigating municipal air quality data and imaging spectrometry for gathering insight into concentrated methane source emissions and highlights how flexible web-based solutions can help facilitate remote sensing research.

  2. Quantitative determination of impurities in nuclear grade aluminum by Flame-Atomic Absorption Spectrometry

    International Nuclear Information System (INIS)

    Jat, J.R.; Nayak, A.K.; Balaji Rao, Y.; Ravindra, H.R.

    2013-01-01

    The paper deals with quantitative determination of impurity elements in nuclear grade aluminum, used as fin tubes in research reactors, by Flame-Atomic Absorption Spectrometry (F-AAS). The results have been compared with those obtained by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) method. Experimental conditions used in both the methods are given in the paper. (author)

  3. Directional and dynamic modulation of the optical emission of an individual GaAs nanowire using surface acoustic waves.

    Science.gov (United States)

    Kinzel, Jörg B; Rudolph, Daniel; Bichler, Max; Abstreiter, Gerhard; Finley, Jonathan J; Koblmüller, Gregor; Wixforth, Achim; Krenner, Hubert J

    2011-04-13

    We report on optical experiments performed on individual GaAs nanowires and the manipulation of their temporal emission characteristics using a surface acoustic wave. We find a pronounced, characteristic suppression of the emission intensity for the surface acoustic wave propagation aligned with the axis of the nanowire. Furthermore, we demonstrate that this quenching is dynamical as it shows a pronounced modulation as the local phase of the surface acoustic wave is tuned. These effects are strongly reduced for a surface acoustic wave applied in the direction perpendicular to the axis of the nanowire due to their inherent one-dimensional geometry. We resolve a fully dynamic modulation of the nanowire emission up to 678 MHz not limited by the physical properties of the nanowires.

  4. Plasmon mediated enhancement and tuning of optical emission properties of two dimensional graphitic carbon nitride nanosheets.

    Science.gov (United States)

    Bayan, Sayan; Gogurla, Narendar; Midya, Anupam; Singha, Achintya; Ray, Samit K

    2017-12-01

    We demonstrate surface plasmon induced enhancement and tunablilty in optical emission properties of two dimensional graphitic carbon nitride (g-C 3 N 4 ) nanosheets through the attachment of gold (Au) nanoparticles. Raman spectroscopy has revealed surface enhanced Raman scattering that arises due to the combined effect of the charge transfer process and localized surface plasmon induced enhancement in electromagnetic field, both occurring at the nanoparticle-nanosheet interface. Photoluminescence studies suggest that at an optimal concentration of nanoparticles, the emission intensity can be enhanced, which is maximum within the 500-525 nm region. Further, the fabricated electroluminescent devices reveal that the emission feature can be tuned from bluish-green to red (∼160 nm shift) upon attaching Au nanoparticles. We propose that the π*→π transition in g-C 3 N 4 can trigger surface plasmon oscillation in Au, which subsequently increases the excitation process in the nanosheets and results in enhanced emission in the green region of the photoluminescence spectrum. On the other hand, electroluminescence of g-C 3 N 4 can induce plasmon oscillation more efficiently and thus can lead to red emission from Au nanoparticles through the radiative damping of particle plasmons. The influence of nanoparticle size and coverage on the emission properties of two dimensional g-C 3 N 4 , nanosheets has also been studied in detail.

  5. Dye linked conjugated homopolymers: using conjugated polymer electroluminescence to optically pump porphyrin-dye emission

    DEFF Research Database (Denmark)

    Nielsen, K.T.; Spanggaard, H.; Krebs, Frederik C

    2004-01-01

    . Electroluminescent devices of the homopolymer itself and of the zinc-porphyrin containing polymer were prepared and the nature of the electroluminescence was characterized. The homopolymer segments were found to optically pump the emission of the zinc-porphyrin dye moities. The homopolymer exhibits blue......Zinc-porphyrin dye molecules were incorporated into the backbone of a conjugated polymer material by a method, which allowed for the incorporation of only one zinc-porphyrin dye molecule into the backbone of each conjugated polymer molecule. The electronic properties of the homopolymer were...

  6. Bidimensional characterization of the emission spectra in a direct current atmospheric pressure glow discharge

    Energy Technology Data Exchange (ETDEWEB)

    Orejas, Jaime [University of Oviedo, Department of Physics, C/ Gonzazlez Quiros S/N, Mieres (Spain); Pisonero, Jorge, E-mail: pisonerojorge@uniovi.es [University of Oviedo, Department of Physics, C/ Gonzazlez Quiros S/N, Mieres (Spain); Bordel, Nerea [University of Oviedo, Department of Physics, C/ Gonzazlez Quiros S/N, Mieres (Spain); Nelis, Thomas [Bern University of Applied Sciences, Quellgasse 21, 2501 Bienne (Switzerland); Guillot, Philippe [DPHE, CUFR J. F. Champollion, Universite de Toulouse, Place de Verdun, Albi (France); Sanz-Medel, Alfredo, E-mail: asm@uniovi.es [University of Oviedo, Department of Physical and Analytical Chemistry, C/ Julian Claveria 8, Oviedo (Spain)

    2012-10-15

    An in-house atmospheric pressure glow discharge source, designed to be used as ionization/desorption source for ambient mass spectrometry, has been electrically characterized, and its optical emission spectra evaluated in detail. Electrical characterization showed that the plasma regime can vary from glow discharge to arc discharge depending on operating conditions (i.e. He flow rate and inter electrode distance). Furthermore, bidimensional images of the optical emission of some plasma species using filters as wavelength selectors, were registered from inside and outside the discharge chamber (inner region and afterglow region respectively), showing the spatial distribution of excited species (i.e. He*, N{sub 2}{sup +} and O*). These distribution patterns are useful to study the chemistry of the discharge plasma, since different production pathways and different excitation energies affect the presence of these species in the plasma regions. - Highlights: Black-Right-Pointing-Pointer An in-house APGD is characterized through electrical and OES measurements. Black-Right-Pointing-Pointer Interelectrode distance had more effect on electric regime than He flow rate. Black-Right-Pointing-Pointer Internal plume images showed differences on the production pathways for each species. Black-Right-Pointing-Pointer Higher interelectrode distances and He flow rates showed better afterglow conditions.

  7. An optical technique to measure the frequency and mode emission of tunable lasers

    International Nuclear Information System (INIS)

    Marchetti, S.; Simili, R.

    1988-01-01

    To use mode tunable lasers it is necessary to measure the laser frequency and the mode emission. This problem is very important when waveguide lasers are used. Normally this information is obtained by a heterodyne technique, but there are some difficulties to perform this method in a large electrical noise environment, when pulsed of radiofrequency lasers are used. This laser information was obtained by using an alternative low-cost optical system. With this apparatus the cavity pulling was measured and an upper limit for the linewidth of a radiofrequency, high pressure, line and mode-tunable, CO 2 laser was roughly estimated

  8. Restoring in-phase emissions from non-planar radiating elements using a transformation optics based lens

    International Nuclear Information System (INIS)

    Yi, Jianjia; Burokur, Shah Nawaz; Lustrac, André de; Piau, Gérard-Pascal

    2015-01-01

    The broadband directive in-phase emission from an array of sources conformed cylindrically is numerically and experimentally reported. Such manipulation is achieved through the use of a lens designed by transformation optics concept. The all-dielectric lens prototype is realized through three-dimensional (3D) polyjet printing and presents a graded refractive index. A microstrip antenna array fabricated using standard lithography techniques and conformed on a cylindrical surface is used as TE-polarized wave launcher for the lens. To experimentally demonstrate the broadband focusing properties and in-phase directive emissions, both the far-field radiation patterns and the near-field distributions have been measured. Experimental measurements agreeing qualitatively with numerical simulations validate the proposed lens and open the way to inexpensive all-dielectric microwave lenses for beam forming and collimation

  9. Restoring in-phase emissions from non-planar radiating elements using a transformation optics based lens

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Jianjia [IEF, CNRS, UMR 8622, Université Paris-Sud, 91405 Orsay Cedex (France); Burokur, Shah Nawaz, E-mail: shah-nawaz.burokur@u-psud.fr; Lustrac, André de [IEF, CNRS, UMR 8622, Université Paris-Sud, 91405 Orsay Cedex (France); Université Paris-Ouest, 92410 Ville d' Avray (France); Piau, Gérard-Pascal [AIRBUS Group Innovations, 92150 Suresnes (France)

    2015-07-13

    The broadband directive in-phase emission from an array of sources conformed cylindrically is numerically and experimentally reported. Such manipulation is achieved through the use of a lens designed by transformation optics concept. The all-dielectric lens prototype is realized through three-dimensional (3D) polyjet printing and presents a graded refractive index. A microstrip antenna array fabricated using standard lithography techniques and conformed on a cylindrical surface is used as TE-polarized wave launcher for the lens. To experimentally demonstrate the broadband focusing properties and in-phase directive emissions, both the far-field radiation patterns and the near-field distributions have been measured. Experimental measurements agreeing qualitatively with numerical simulations validate the proposed lens and open the way to inexpensive all-dielectric microwave lenses for beam forming and collimation.

  10. Physics design of the in-vessel collection optics for the ITER electron cyclotron emission diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Rowan, W. L., E-mail: w.l.rowan@austin.utexas.edu; Houshmandyar, S.; Phillips, P. E.; Austin, M. E. [Institute for Fusion Studies, The University of Texas at Austin, Austin, Texas 78712 (United States); Beno, J. H.; Ouroua, A. [Center for Electromechanics, The University of Texas at Austin, Austin, Texas 78712 (United States); Hubbard, A. E. [Plasma Science and Fusion Center, MIT, Cambridge, Massachusetts 02139 (United States); Khodak, A.; Taylor, G. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2016-11-15

    Measurement of the electron cyclotron emission (ECE) is one of the primary diagnostics for electron temperature in ITER. In-vessel, in-vacuum, and quasi-optical antennas capture sufficient ECE to achieve large signal to noise with microsecond temporal resolution and high spatial resolution while maintaining polarization fidelity. Two similar systems are required. One views the plasma radially. The other is an oblique view. Both views can be used to measure the electron temperature, while the oblique is also sensitive to non-thermal distortion in the bulk electron distribution. The in-vacuum optics for both systems are subject to degradation as they have a direct view of the ITER plasma and will not be accessible for cleaning or replacement for extended periods. Blackbody radiation sources are provided for in situ calibration.

  11. Determination of daily intake of elements from Philippine total diet samples using inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Leon, G.C. de; Shiraishi, K.; Kawamura, H.; Igaraishi, Y.; Palattao, M.V.; Azanon, E.M.

    1990-10-01

    Total diet samples were analyzed for major elements (Na, K, Ca, Mg, P) and some minor trace elements (Fe, Zn, Mn, Al, Sr, Cu, Ba, Yt) using inductively coupled plasma-atomic emission spectrometry (ICP-AES). Samples analyzed were classified into sex and age groups. Results for some elements (Na, K, Mg, Zn, Cu, Mn) were compared with values from Bataan dietary survey calculated using the Philippine composition table. Exceot for Na, analytical results were similar to calculated values. Analytical results for Ca and Fe were also compared with the values from Food and Nutrition Research Institute. In general, values obtained in the study were lower than the FNRI values. Comparison of the analytical and calculated results with the Japanese and ICRP data showed that Philippine values were lower than foreign values. (Auth.). 22 refs., 9 tabs

  12. Tunable laser optics

    CERN Document Server

    Duarte, FJ

    2015-01-01

    This Second Edition of a bestselling book describes the optics and optical principles needed to build lasers. It also highlights the optics instrumentation necessary to characterize laser emissions and focuses on laser-based optical instrumentation. The book emphasizes practical and utilitarian aspects of relevant optics including the essential theory. This revised, expanded, and improved edition contains new material on tunable lasers and discusses relevant topics in quantum optics.

  13. Critical Temperature for the Conversion from Wurtzite to Zincblende of the Optical Emission of InAs Nanowires

    KAUST Repository

    Rota, Michele B.

    2017-07-12

    One hour annealing at 300 degrees C changes the optical emission characteristics of InAs nanowires (NWs) from the wurtzite (WZ) phase into that of zincblende (ZB). These results are accounted for by the conversion of a small fraction of the NW WZ metastable structure into the stable ZB structure. Several paths toward the polytype transformation in the configuration space are also demonstrated using first-principles calculations. For lower annealing temperatures, emission which is likely related to WZ polytypes is observed at energies that agree with theoretical predictions. These results demonstrate severe constraints on thermal processes to which devices made from InAs WZ NWs can be exposed.

  14. Reverberation Mapping of Optical Emission Lines in Five Active Galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Fausnaugh, M. M.; Denney, K. D.; Peterson, B. M.; Kochanek, C. S.; Pogge, R. W.; Brown, Jonathan S.; Coker, C. T. [Department of Astronomy, The Ohio State University, 140 W. 18th Avenue, Columbus, OH 43210 (United States); Grier, C. J.; Beatty, Thomas G. [Department of Astronomy and Astrophysics, The Pennsylvania State University, 525 Davey Laboratory, University Park, PA 16802 (United States); Bentz, M. C. [Department of Physics and Astronomy, Georgia State University, Atlanta, GA 30303 (United States); Rosa, G. De [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Adams, S. M. [Cahill Center for Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Barth, A. J. [Department of Physics and Astronomy, 4129 Frederick Reines Hall, University of California, Irvine, CA 92697 (United States); Bhattacharjee, A.; Brotherton, M. S. [Department of Physics and Astronomy, University of Wyoming, 1000 E. University Avenue, Laramie, WY (United States); Borman, G. A. [Crimean Astrophysical Observatory, P/O Nauchny, Crimea 298409 (Russian Federation); Boroson, T. A. [Las Cumbres Global Telescope Network, 6740 Cortona Drive, Suite 102, Santa Barbara, CA 93117 (United States); Bottorff, M. C. [Fountainwood Observatory, Department of Physics FJS 149, Southwestern University, 1011 E. University Avenue, Georgetown, TX 78626 (United States); Brown, Jacob E. [Department of Physics and Astronomy, University of Missouri, Columbia (United States); Crawford, S. M. [South African Astronomical Observatory, P.O. Box 9, Observatory 7935, Cape Town (South Africa); and others

    2017-05-10

    We present the first results from an optical reverberation mapping campaign executed in 2014 targeting the active galactic nuclei (AGNs) MCG+08-11-011, NGC 2617, NGC 4051, 3C 382, and Mrk 374. Our targets have diverse and interesting observational properties, including a “changing look” AGN and a broad-line radio galaxy. Based on continuum-H β lags, we measure black hole masses for all five targets. We also obtain H γ and He ii λ 4686 lags for all objects except 3C 382. The He ii λ 4686 lags indicate radial stratification of the BLR, and the masses derived from different emission lines are in general agreement. The relative responsivities of these lines are also in qualitative agreement with photoionization models. These spectra have extremely high signal-to-noise ratios (100–300 per pixel) and there are excellent prospects for obtaining velocity-resolved reverberation signatures.

  15. Reverberation Mapping of Optical Emission Lines in Five Active Galaxies

    International Nuclear Information System (INIS)

    Fausnaugh, M. M.; Denney, K. D.; Peterson, B. M.; Kochanek, C. S.; Pogge, R. W.; Brown, Jonathan S.; Coker, C. T.; Grier, C. J.; Beatty, Thomas G.; Bentz, M. C.; Rosa, G. De; Adams, S. M.; Barth, A. J.; Bhattacharjee, A.; Brotherton, M. S.; Borman, G. A.; Boroson, T. A.; Bottorff, M. C.; Brown, Jacob E.; Crawford, S. M.

    2017-01-01

    We present the first results from an optical reverberation mapping campaign executed in 2014 targeting the active galactic nuclei (AGNs) MCG+08-11-011, NGC 2617, NGC 4051, 3C 382, and Mrk 374. Our targets have diverse and interesting observational properties, including a “changing look” AGN and a broad-line radio galaxy. Based on continuum-H β lags, we measure black hole masses for all five targets. We also obtain H γ and He ii λ 4686 lags for all objects except 3C 382. The He ii λ 4686 lags indicate radial stratification of the BLR, and the masses derived from different emission lines are in general agreement. The relative responsivities of these lines are also in qualitative agreement with photoionization models. These spectra have extremely high signal-to-noise ratios (100–300 per pixel) and there are excellent prospects for obtaining velocity-resolved reverberation signatures.

  16. In-situ determination of cross-over point for overcoming plasma-related matrix effects in inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Chan, George C.-Y.; Hieftje, Gary M.

    2008-01-01

    A novel method is described for overcoming plasma-related matrix effects in inductively coupled plasma-atomic emission spectrometry (ICP-AES). The method is based on measurement of the vertically resolved atomic emission of analyte within the plasma and therefore requires the addition of no reagents to the sample solution or to the plasma. Plasma-related matrix effects enhance analyte emission intensity low in the plasma but depress the same emission signal at higher positions. Such bipolar behavior is true for all emission lines and matrices that induce plasma-related interferences. The transition where the enhancement is balanced by the depression (the so-called cross-over point) results in a spatial region with no apparent matrix effects. Although it would be desirable always to perform determinations at this cross-over point, its location varies between analytes and from matrix to matrix, so it would have to be found separately for every analyte and for every sample. Here, a novel approach is developed for the in-situ determination of the location of this cross-over point. It was found that the location of the cross-over point is practically invariant for a particular analyte emission line when the concentration of the matrix was varied. As a result, it is possible to determine in-situ the location of the cross-over point for all analyte emission lines in a sample by means of a simple one-step sample dilution. When the original sample is diluted by a factor of 2 and the diluted sample is analyzed again, the extent of the matrix effect is identical (zero) between the original sample and the diluted sample at one and only one location - the cross-over point. This novel method was verified with several single-element matrices (0.05 M Na, Ca, Ba and La) and some mixed-element matrices (mixtures of Na-Ca, Ca-Ba, and a plant-sample digest). The inaccuracy in emission intensity due to the matrix effect could be as large as - 30% for conventional measurements in the

  17. 134Cs emission probabilities determination by gamma spectrometry

    Science.gov (United States)

    de Almeida, M. C. M.; Poledna, R.; Delgado, J. U.; Silva, R. L.; Araujo, M. T. F.; da Silva, C. J.

    2018-03-01

    The National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) of Rio de Janeiro performed primary and secondary standardization of different radionuclides reaching satisfactory uncertainties. A solution of 134Cs radionuclide was purchased from commercial supplier to emission probabilities determination of some of its energies. 134Cs is a beta gamma emitter with 754 days of half-life. This radionuclide is used as standard in environmental, water and food control. It is also important to germanium detector calibration. The gamma emission probabilities (Pγ) were determined mainly for some energies of the 134Cs by efficiency curve method and the Pγ absolute uncertainties obtained were below 1% (k=1).

  18. A tool to separate optical/infrared disc and jet emission in X-ray transient outbursts: the colour-magnitude diagrams of XTE J1550-564

    NARCIS (Netherlands)

    Russell, D.M.; Maitra, D.; Dunn, R.J.H.; Fender, R.P.

    2011-01-01

    It is now established that thermal disc emission and non-thermal jet emission can both play a role at optical/infrared (OIR) wavelengths in X-ray transients. The spectra of the jet and disc components differ, as do their dependence on mass accretion properties. Here we demonstrate that the OIR

  19. Application of femtosecond laser ablation inductively coupled plasma mass spectrometry for quantitative analysis of thin Cu(In,Ga)Se{sub 2} solar cell films

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seokhee [School of Mechatronics, Gwangju Institute of Science and Technology, 1 Oryong-dong, Buk-gu, Gwangju 500-712 (Korea, Republic of); Gonzalez, Jhanis J. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Applied Spectra Inc., 46665 Fremont Boulevard, Fremont, CA 94538 (United States); Yoo, Jong H. [Applied Spectra Inc., 46665 Fremont Boulevard, Fremont, CA 94538 (United States); Chirinos, Jose R. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Facultad de Ciencias, Universidad Central de Venezuela, Caracas 1041A (Venezuela, Bolivarian Republic of); Russo, Richard E. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Applied Spectra Inc., 46665 Fremont Boulevard, Fremont, CA 94538 (United States); Jeong, Sungho, E-mail: shjeong@gist.ac.kr [School of Mechatronics, Gwangju Institute of Science and Technology, 1 Oryong-dong, Buk-gu, Gwangju 500-712 (Korea, Republic of)

    2015-02-27

    This work reports that the composition of Cu(In,Ga)Se{sub 2} (CIGS) thin solar cell films can be quantitatively predicted with high accuracy and precision by femtosecond laser ablation-inductively coupled plasma-mass spectrometry (fs-LA-ICP-MS). It is demonstrated that the results are strongly influenced by sampling conditions during fs-laser beam (λ = 1030 nm, τ = 450 fs) scanning on the CIGS surface. The fs-LA-ICP-MS signals measured at optimal sampling conditions generally provide a straight line calibration with respect to the reference concentrations measured by inductively coupled plasma optical emission spectroscopy (ICP-OES). The concentration ratios predicted by fs-LA-ICP-MS showed high accuracy, to 95–97% of the values measured with ICP-OES, for Cu, In, Ga, and Se elements. - Highlights: • Laser ablation inductively coupled plasma mass spectrometry of thin film is reported. • Concentration ratio prediction with a confidence level of 95–97% is achieved. • Quantitative determination of composition is demonstrated.

  20. Laser based analysis using a passively Q-switched laser employing analysis electronics and a means for detecting atomic optical emission of the laser media

    Science.gov (United States)

    Woodruff, Steven D.; Mcintyre, Dustin L.

    2016-03-29

    A device for Laser based Analysis using a Passively Q-Switched Laser comprising an optical pumping source optically connected to a laser media. The laser media and a Q-switch are positioned between and optically connected to a high reflectivity mirror (HR) and an output coupler (OC) along an optical axis. The output coupler (OC) is optically connected to the output lens along the optical axis. A means for detecting atomic optical emission comprises a filter and a light detector. The optical filter is optically connected to the laser media and the optical detector. A control system is connected to the optical detector and the analysis electronics. The analysis electronics are optically connected to the output lens. The detection of the large scale laser output production triggers the control system to initiate the precise timing and data collection from the detector and analysis.

  1. Effects of air exchange, temperature and slurry management on odorant emissions from pig production units and slurry tanks studied by proton-transfer-reaction mass spectrometry (PTR-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Feilberg, A.; Adamsen, A.P.S.; Liu, D.; Hansen, M.J.; Bildsoe, P. [Aarhus Univ., Tjele (Denmark). Dept. of Biosystems Engineering

    2010-07-01

    The factors affecting the variability of odorant emissions from intensive pig production facilities were examined using proton-transfer-reaction mass spectrometry (PTR-MS) to monitor emissions of odorants. Quantitative and time-resolved results for protonated ions representing hydrogen sulphide (H{sub 2}S), volatile organic sulphur compounds, organic amines, volatile carboxylic acids, carbonyls, phenols and indoles can be obtained. This study presented the results from PTRMS measurements of odorant emissions from finisher pig houses and finisher manure storage tanks. The measurements were performed at an experimental full-scale pig section with mechanical ventilation and at an experimental manure storage facility with controlled air exchange. Field measurements were taken during variable air exchange rates and temperatures, during finisher growth, and during emptying of the slurry pit. The results revealed a pronounced diurnal variation in emissions of odorants from the pig section with peaks in daytime coinciding with the highest ventilation rates and highest room temperatures. The highest emission rates were observed for H{sub 2}S and carboxylic acids. Based on odour threshold values, methanethiol and 4-methylphenol were estimated to contribute considerably to the odour nuisance. Discharging of the slurry pit led to reduced H{sub 2}S emissions, but peaks of H{sub 2}S were observed during manure handling.

  2. Laser-induced carbon plasma emission spectroscopic measurements on solid targets and in gas-phase optical breakdown

    International Nuclear Information System (INIS)

    Nemes, Laszlo; Keszler, Anna M.; Hornkohl, James O.; Parigger, Christian

    2005-01-01

    We report measurements of time- and spatially averaged spontaneous-emission spectra following laser-induced breakdown on a solid graphite/ambient gas interface and on solid graphite in vacuum, and also emission spectra from gas-phase optical breakdown in allene C3H4 and helium, and in CO2 and helium mixtures. These emission spectra were dominated by CII (singly ionized carbon), CIII (doubly ionized carbon), hydrogen Balmer beta (H b eta), and Swan C2 band features. Using the local thermodynamic equilibrium and thin plasma assumptions, we derived electron number density and electron temperature estimates. The former was in the 1016 cm -3 range, while the latter was found to be near 20000 K. In addition, the vibration-rotation temperature of the Swan bands of the C2 radical was determined to be between 4500 and 7000 K, using an exact theoretical model for simulating diatomic emission spectra. This temperature range is probably caused by the spatial inhomogeneity of the laser-induced plasma plume. Differences are pointed out in the role of ambient CO2 in a solid graphite target and in gas-phase breakdown plasma

  3. Diagnostics of helium plasma by collisional-radiative modeling and optical emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Wonwook; Kwon, Duck-Hee [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    Optical diagnostics for the electron temperature (T{sub e}) and the electron density (n{sub e}) of fusion plasma is important for understanding and controlling the edge and the divertor plasmas in tokamak. Since the line intensity ratio method using the collisional-radiative modeling and OES (optical emission spectroscopy) is simple and does not disturb the plasma, many fusion devices with TEXTOR, JET, JT-60U, LHD, and so on, have employed the line intensity ratio method as a basic diagnostic tool for neutral helium (He I). The accuracy of the line intensity ratio method depends on the reliability of the cross sections and rate coefficients. We performed state-of-the-art R-matrix calculations including couplings up to n=7 states and the distorted wave (DW) calculations for the electron-impact excitation (EIE) cross sections of He I using the flexible atomic code (FAC). The collisional-radiative model for He I was constructed using the calculated the cross sections. The helium collisional-radiative model for He I was constructed to diagnose the electron temperature and the electron density of the plasma. The electron temperature and density were determined by using the line intensity ratio method.

  4. Semi-automated technique for the separation and determination of barium and strontium in surface waters by ion exchange chromatography and atomic emission spectrometry

    International Nuclear Information System (INIS)

    Pierce, F.D.; Brown, H.R.

    1977-01-01

    A semi-automated method for the separation and the analysis of barium and strontium in surface waters by atomic emission spectrometry is described. The method employs a semi-automated separation technique using ion exchange and an automated aspiration-analysis procedure. Forty specimens can be prepared in approximately 90 min and can be analyzed for barium and strontium content in 20 min. The detection limits and sensitivities provided by the described technique are 0.003 mg/l and 0.01 mg/l respectively for barium and 0.00045 mg/l and 0.003 mg/l respectively for strontium

  5. Apparatus and method for transient thermal infrared emission spectrometry

    Science.gov (United States)

    McClelland, John F.; Jones, Roger W.

    1991-12-24

    A method and apparatus for enabling analysis of a solid material (16, 42) by applying energy from an energy source (20, 70) top a surface region of the solid material sufficient to cause transient heating in a thin surface layer portion of the solid material (16, 42) so as to enable transient thermal emission of infrared radiation from the thin surface layer portion, and by detecting with a spectrometer/detector (28, 58) substantially only the transient thermal emission of infrared radiation from the thin surface layer portion of the solid material. The detected transient thermal emission of infrared radiation is sufficiently free of self-absorption by the solid material of emitted infrared radiation, so as to be indicative of characteristics relating to molecular composition of the solid material.

  6. OPTICAL LINE EMISSION IN BRIGHTEST CLUSTER GALAXIES AT 0 < z < 0.6: EVIDENCE FOR A LACK OF STRONG COOL CORES 3.5 Gyr AGO?

    International Nuclear Information System (INIS)

    McDonald, Michael

    2011-01-01

    In recent years the number of known galaxy clusters beyond z ∼> 0.2 has increased drastically with the release of multiple catalogs containing >30,000 optically detected galaxy clusters over the range 0 0.3, hinting at an earlier epoch of strong cooling. We compare the evolution of emission-line nebulae to the X-ray-derived cool core (CC) fraction from the literature over the same redshift range and find overall agreement, with the exception that an upturn in the strong CC fraction is not observed at z > 0.3. The overall agreement between the evolution of CCs and optical line emission at low redshift suggests that emission-line surveys of galaxy clusters may provide an efficient method of indirectly probing the evolution of CCs and thus provide insights into the balance of heating and cooling processes at early cosmic times.

  7. Plasma control using neural network and optical emission spectroscopy

    International Nuclear Information System (INIS)

    Kim, Byungwhan; Bae, Jung Ki; Hong, Wan-Shick

    2005-01-01

    Due to high sensitivity to process parameters, plasma processes should be tightly controlled. For plasma control, a predictive model was constructed using a neural network and optical emission spectroscopy (OES). Principal component analysis (PCA) was used to reduce OES dimensionality. This approach was applied to an oxide plasma etching conducted in a CHF 3 /CF 4 magnetically enhanced reactive ion plasma. The etch process was systematically characterized by means of a statistical experimental design. Three etch outputs (etch rate, profile angle, and etch rate nonuniformity) were modeled using three different approaches, including conventional, OES, and PCA-OES models. For all etch outputs, OES models demonstrated improved predictions over the conventional or PCA-OES models. Compared to conventional models, OES models yielded an improvement of more than 25% in modeling profile angle and etch rate nonuniformtiy. More than 40% improvement over PCA-OES model was achieved in modeling etch rate and profile angle. These results demonstrate that nonreduced in situ data are more beneficial than reduced one in constructing plasma control model

  8. Modification of Optical Properties of Seawater Exposed to Oil Contaminants Based on Excitation-Emission Spectra

    Science.gov (United States)

    Baszanowska, E.; Otremba, Z.

    2015-10-01

    The optical behaviour of seawater exposed to a residual amount of oil pollution is presented and a comparison of the fluorescence spectra of oil dissolved in both n-hexane and seawater is discussed based on excitation-emission spectra. Crude oil extracted from the southern part of the Baltic Sea was used to characterise petroleum properties after contact with seawater. The wavelength-independent fluorescence maximum for natural seawater and seawater artificially polluted with oil were determined. Moreover, the specific excitation-emission peaks for natural seawater and polluted water were analysed to identify the natural organic matter composition. It was found that fluorescence spectra identification is a promising method to detect even an extremely low concentration of petroleum residues directly in the seawater. In addition, alien substances disturbing the fluorescence signatures of natural organic substances in a marine environment is also discussed.

  9. Determination of low cadmium concentrations in wine by on-line preconcentration in a knotted reactor coupled to an inductively coupled plasma optical emission spectrometer with ultrasonic nebulization

    Energy Technology Data Exchange (ETDEWEB)

    Lara, R.F. [Inst. de Investigaciones Mineras, Universidad Nacional de San Juan (Argentina); Wuilloud, R.G.; Salonia, J.A. [Dept. of Analytical Chemistry, National University of San Luis (Argentina); Olsina, R.A.; Martinez, L.D. [Dept. of Analytical Chemistry, National University of San Luis (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina)

    2001-12-01

    An on-line cadmium preconcentration and determination system implemented with inductively coupled plasma optical emission spectrometry (ICP-OES) associated to flow injection (FI) with ultrasonic nebulization system (USN) was studied. The cadmium was retained as the cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol, Cd-(5-Br-PADAP), complex, at pH 9.5. The cadmium complex was removed from the knotted reactor (KR) with 3.0 mol/L nitric acid. A total enhancement factor of 216 was obtained with respect to ICP-OES using pneumatic nebulization (12 for USN and 18 for KR) with a preconcentration time of 60 s. The value of the detection limit for the preconcentration of 5 mL of sample solution was 5 ng/L. The precision for 10 replicate determinations at the 5 {mu}g/L Cd level was 2.9% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for cadmium was linear with a correlation coefficient of 0.9998 at levels near the detection limits up to at least 1000 {mu}g/L. The method was successfully applied to the determination of cadmium in wine samples. (orig.)

  10. Experimental characterization of true spontaneous emission rate of optically-pumped InGaAs/GaAs quantum-well laser structure

    Directory of Open Access Journals (Sweden)

    Q.-N. Yu

    2017-08-01

    Full Text Available In this paper, an experimental approach to acquiring true spontaneous emission rate of optically-pumped InGaAs/GaAs quantum-well laser structure is described. This method is based on a single edge-emitting laser chip with simple sample processing. The photoluminescence spectra are measured at both facets of the edge-emitting device and transformed to the spontaneous emission rate following the theory described here. The unusual double peaks appearing in the spontaneous emission rate spectra are observed for the InGaAs/GaAs quantum-well structure. The result is analyzed in terms of Indium-rich island and Model-Solid theories. The proposed method is suitable for electrically-pumped quantum-well laser structures, as well.

  11. Noise in Optical Amplifiers

    DEFF Research Database (Denmark)

    Jeppesen, Palle

    1997-01-01

    Noise in optical amplifiers is discussed on the basis of photons and electromagntic fields. Formulas for quantum noise from spontaneous emission, signal-spontaneous beat noise and spontaneous-spontaneous beat noise are derived.......Noise in optical amplifiers is discussed on the basis of photons and electromagntic fields. Formulas for quantum noise from spontaneous emission, signal-spontaneous beat noise and spontaneous-spontaneous beat noise are derived....

  12. Spatially resolvable optical emission spectrometer for analyzing density uniformity of semiconductor process plasma

    International Nuclear Information System (INIS)

    Oh, Changhoon; Ryoo, Hoonchul; Lee, Hyungwoo; Hahn, Jae W.; Kim, Se-Yeon; Yi, Hun-Jung

    2010-01-01

    We proposed a spatially resolved optical emission spectrometer (SROES) for analyzing the uniformity of plasma density for semiconductor processes. To enhance the spatial resolution of the SROES, we constructed a SROES system using a series of lenses, apertures, and pinholes. We calculated the spatial resolution of the SROES for the variation of pinhole size, and our calculated results were in good agreement with the measured spatial variation of the constructed SROES. The performance of the SROES was also verified by detecting the correlation between the distribution of a fluorine radical in inductively coupled plasma etch process and the etch rate of a SiO 2 film on a silicon wafer.

  13. Tecnical Note: Analysis of non-regulated vehicular emissions by extractive FTIR spectrometry: tests on a hybrid car in Mexico City

    Science.gov (United States)

    Reyes, F.; Grutter, M.; Jazcilevich, A.; González-Oropeza, R.

    2006-11-01

    A methodology to acquire valuable information on the chemical composition and evolution of vehicular emissions is presented. The analysis of the gases is performed by passing a constant flow of a sample gas from the tail-pipe into a 10 L multi-pass cell. The absorption spectra within the cell are obtained using an FTIR spectrometer at 0.5 cm-1 resolution along a 13.1 m optical path. Additionally, the total flow from the exhaust is continuously measured from a differential pressure sensor on a textit{Pitot} tube installed at the exit of the exhaust. This configuration aims to obtain a good speciation capability by coadding spectra during 30 s and reporting the emission (in g/km) of both criteria and non-regulated pollutants, such as CO2, CO, NO, SO2, NH3, HCHO and some NMHC, during predetermined driving cycles. The advantages and disadvantages of increasing the measurement frequency, as well as the effect of other parameters such as spectral resolution, cell volume and flow rate, are discussed. To test and evaluate the proposed technique, experiments were performed on a dynamometer running FTP-75 and typical driving cycles for the Mexico City Metropolitan Area (MCMA) on a Toyota Prius hybrid vehicle. This car is an example of recent marketed automotive technology dedicated to reduced emissions, increasing the need for sensitive detection techniques. This study shows the potential of the proposed technique to measure and report in real time the emissions of a large variety of pollutants, even from a super ultra-low emission vehicle (SULEV). The emissions of HC's, NOx, CO and CO2 obtained here were compared to experiments performed in other locations with the same model vehicle. The proposed technique provides a tool for future studies comparing in detail the emissions of vehicles using alternative fuels and emission control systems.

  14. Tecnical Note: Analysis of non-regulated vehicular emissions by extractive FTIR spectrometry: tests on a hybrid car in Mexico City

    Directory of Open Access Journals (Sweden)

    F. Reyes

    2006-01-01

    Full Text Available A methodology to acquire valuable information on the chemical composition and evolution of vehicular emissions is presented. The analysis of the gases is performed by passing a constant flow of a sample gas from the tail-pipe into a 10 L multi-pass cell. The absorption spectra within the cell are obtained using an FTIR spectrometer at 0.5 cm−1 resolution along a 13.1 m optical path. Additionally, the total flow from the exhaust is continuously measured from a differential pressure sensor on a extit{Pitot} tube installed at the exit of the exhaust. This configuration aims to obtain a good speciation capability by coadding spectra during 30 s and reporting the emission (in g/km of both criteria and non-regulated pollutants, such as CO2, CO, NO, SO2, NH3, HCHO and some NMHC, during predetermined driving cycles. The advantages and disadvantages of increasing the measurement frequency, as well as the effect of other parameters such as spectral resolution, cell volume and flow rate, are discussed. To test and evaluate the proposed technique, experiments were performed on a dynamometer running FTP-75 and typical driving cycles for the Mexico City Metropolitan Area (MCMA on a Toyota Prius hybrid vehicle. This car is an example of recent marketed automotive technology dedicated to reduced emissions, increasing the need for sensitive detection techniques. This study shows the potential of the proposed technique to measure and report in real time the emissions of a large variety of pollutants, even from a super ultra-low emission vehicle (SULEV. The emissions of HC's, NOx, CO and CO2 obtained here were compared to experiments performed in other locations with the same model vehicle. The proposed technique provides a tool for future studies comparing in detail the emissions of vehicles using alternative fuels and emission control systems.

  15. High-resolution continuum-source atomic absorption spectrometry: what can we expect?

    Directory of Open Access Journals (Sweden)

    Welz Bernhard

    2003-01-01

    Full Text Available A new instrumental concept has been developed for atomic absorption spectrometry (AAS, using a high-intensity xenon short-arc lamp as continuum radiation source, a high-resolution double-echelle monochromator and a CCD array detector, providing a resolution of ~2 pm per pixel. Among the major advantages of the system are: i an improved signal-to-noise ratio because of the high intensity of the radiation source, resulting in improved photometric precision and detection limits; ii for the same reason, there are no more 'weak' lines, i.e. secondary lines can be used without compromises; iii new elements might be determined, for which no radiation source has been available; iv the entire spectral environment around the analytical line becomes 'visible', giving a lot more information than current AAS instruments; v the CCD array detector allows a truly simultaneous background correction close to the analytical line; vi the software is capable of storing reference spectra, e.g. of a molecular absorption with rotational fine structure, and of subtracting such spectra from the spectra recorded for a sample, using a least squares algorithm; vii although not yet realized, the system makes possible a truly simultaneous multi-element AAS measurement when an appropriate two-dimensional detector is used, as is already common practice in optical emission spectrometry; vii preliminary experiments have indicated that the instrumental concept could result in a more rugged analytical performance in the determination of trace elements in complex matrices.

  16. Effect of equatorial electrodynamics on low-latitude thermosphere as inferred from neutral optical dayglow emission observations

    Science.gov (United States)

    Karan, D. K.; Duggirala, P. R.

    2017-12-01

    The diurnal variations in daytime airglow emission intensity measurements at three wavelengths OI 777.4 nm, OI 630.0 nm, and OI 557.7 nm made from a low-latitude location, Hyderabad (Geographic 17.50 N, 78.40 E; 8.90 N Mag. Lat) in India have been investigated. The intensity patterns showed both symmetric and asymmetric behavior in their respective diurnal emission variability with respect to local noon. The asymmetric diurnal behavior is not expected considering the photochemical nature of the production mechanisms. The reason for this observed asymmetric diurnal behavior has been found to be predominantly the temporal variation in the equatorial electrodynamics. The plasma that is transported across latitudes due to the action of varying electric field strength over the magnetic equator in the daytime contributes to the asymmetric diurnal behavior in the neutral daytime airglow emissions. Independent magnetic and radio measurements support this finding. It is also noted that this asymmetric diurnal behavior in the neutral emission intensities has a solar cycle dependence with more number of days during high solar activity period showing asymmetric diurnal behavior compared to those during low-solar activity epoch. These intensity variations over long time scale demonstrate that the daytime neutral optical emissions are extremely sensitive to the changes in the eastward electric field over low- and equatorial-latitudes.

  17. Thermally emissive sensing materials for chemical spectroscopy analysis

    Science.gov (United States)

    Poole, Zsolt; Ohodnicki, Paul R.

    2018-05-08

    A sensor using thermally emissive materials for chemical spectroscopy analysis includes an emissive material, wherein the emissive material includes the thermally emissive materials which emit electromagnetic radiation, wherein the electromagnetic radiation is modified due to chemical composition in an environment; and a detector adapted to detect the electromagnetic radiation, wherein the electromagnetic radiation is indicative of the chemical interaction changes and hence chemical composition and/or chemical composition changes of the environment. The emissive material can be utilized with an optical fiber sensor, with the optical fiber sensor operating without the emissive material probed with a light source external to the material.

  18. [Study on plasma temperature of a large area surface discharge by optical emission spectrum].

    Science.gov (United States)

    Dong, Li-Fang; Tong, Guo-Liang; Zhang, Yu; Zhou, Bin

    2014-04-01

    A large area surface discharge was realized in air/argon gas mixture by designing a discharge device with water electrodes. By using optical emission spectrum, the variations of the molecular vibrational temperature, the mean energy of electron, and the electronic excitation temperature as a function of the gas pressure were studied. The nitrogen molecular vibrational temperature was calculated according to the emission line of the second positive band system of the nitrogen molecule (C3 pi(u) --> B 3 pi(g)). The electronic excitation temperature was obtained by using the intensity ratio of Ar I 763.51 nm (2P(6) --> 1S(5)) to Ar I 772.42 nm (2P(2) --> 1S(3)). The changes in the mean energy of electron were studied by the relative intensity ratio of the nitrogen molecular ion 391.4 nm to nitrogen 337.1 nm. It was found that the intensity of emission spectral line increases with the increase in the gas pressure, meanwhile, the outline and the ratios of different spectral lines intensity also change. The molecular vibrational temperature, the mean energy of electron, and the electronic excitation temperature decrease as the gas pressure increases from 0.75 x 10(5) Pa to 1 x 10(5) Pa.

  19. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  20. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  1. THE NATURE OF OPTICALLY DULL ACTIVE GALACTIC NUCLEI IN COSMOS

    International Nuclear Information System (INIS)

    Trump, Jonathan R.; Impey, Chris D.; Gabor, Jared M.; Taniguchi, Yoshi; Nagao, Tohru; Shioya, Yasuhiro; Brusa, Marcella; Civano, Francesca; Elvis, Martin; Kelly, Brandon C.; Huchra, John P.; Jahnke, Knud; Koekemoer, Anton M.; Salvato, Mara; Capak, Peter; Scoville, Nick Z.; Kartaltepe, Jeyhan S.; Lanzuisi, Giorgio; McCarthy, Patrick J.; Maineri, Vincenzo

    2009-01-01

    We present infrared, optical, and X-ray data of 48 X-ray bright, optically dull active galactic nuclei (AGNs) in the COSMOS field. These objects exhibit the X-ray luminosity of an AGN but lack broad and narrow emission lines in their optical spectrum. We show that despite the lack of optical emission lines, most of these optically dull AGNs are not well described by a typical passive red galaxy spectrum: instead they exhibit weak but significant blue emission like an unobscured AGN. Photometric observations over several years additionally show significant variability in the blue emission of four optically dull AGNs. The nature of the blue and infrared emission suggest that the optically inactive appearance of these AGNs cannot be caused by obscuration intrinsic to the AGNs. Instead, up to ∼70% of optically dull AGNs are diluted by their hosts, with bright or simply edge-on hosts lying preferentially within the spectroscopic aperture. The remaining ∼30% of optically dull AGNs have anomalously high f X /f O ratios and are intrinsically weak, not obscured, in the optical. These optically dull AGNs are best described as a weakly accreting AGN with a truncated accretion disk from a radiatively inefficient accretion flow.

  2. Cu,Cr and As determination in preserved woods (Eucalyptus ssp.) by X-ray fluorescence spectrometries; Determinacao de cobre, cromo e arsenio em madeira preservada (Eucalyptus sp.) pelas espectrometrias de fluorescencia de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Pereira Junior, Sergio Matias

    2014-07-01

    Brazil produces around 2.2 millions of cubic meters of treated wood to meet the annual demand of railway, electric, rural and construction sectors. The most used wood species are eucalyptus (Eucalyptus ssp.) and pine (Pinus ssp.).The treated woods used for poles, sleepers, fence posts and plywoods should be according to Brazilian norms requirements. The most usual wood preservative products used in Brazil are CCA (chromated copper arsenate) and CCB (copper chromium and boron salt). The analytical methods, such as flame atomic absorption spectrometry (FAAS), plasma inductively coupled optical emission spectrometry (ICPOES) and X-ray fluorescence spectrometry (XRFS) have been used for the analytical control of those treatment processes. In this work, the eucalyptus trees (Eucalyptus ssp) samples was obtained from Minas Gerais State, Brazil, cut plantation areas. Under pressure, eucalyptus wood samples were submitted to different concentration of CCA solution reaching 3.9, 6.7, 9.1, 12.4 and 14.0 kg of CCA by m-³ sapwood retentions. Samples in cylinders and sawdust forms were obtained from treated wood samples. Copper, chromium and arsenic determination was performed using the energy dispersive X-ray fluorescence spectrometry (EDXRFS), portable X-ray fluorescence spectrometry (PXRFS), flame atomic absorption spectrometry (FAAS) and instrumental neutron activation analysis. In this work, the method of analysis, sensitivity, precision and accuracy performances of the related techniques were outlined. (author)

  3. [Optical emission analyses of N2/TMG ECR plasma for deposition of GaN film].

    Science.gov (United States)

    Fu, Si-Lie; Wang, Chun-An; Chen, Jun-Fang

    2013-04-01

    The optical emission spectroscopy of hybrid N2/trimethylgallium (TMG) plasma in an ECR-PECVD system was investigated. The results indicate that the TMG gas is strongly dissociated into Ga*, CH and H even under self-heating condition. Ga species and nitrogen molecule in metastable state are dominant in hybrid ECR plasma. The concentration of metastable nitrogen molecule increases with the microwave power. On the other hand, the concentration of excited nitrogen molecules and of nitrogen ion decreases when the microwave power is higher than 400 W.

  4. Optical Spectroscopy of SDSS J004054.65-0915268: Three Possible Scenarios for the Classification. A z ˜ 5 BL Lacertae, a Blue FSRQ, or a Weak Emission Line Quasar

    Science.gov (United States)

    Landoni, M.; Zanutta, A.; Bianco, A.; Tavecchio, F.; Bonnoli, G.; Ghisellini, G.

    2016-02-01

    The haunt of high-redshift BL Lacerate objects is day by day more compelling to firmly understand their intrinsic nature and evolution. SDSS J004054.65-0915268 is, at the moment, one of the most distant BL Lac candidates, at z ˜ 5. We present a new optical-near-IR spectrum obtained with ALFOSC-NOT with a new, custom designed dispersive grating aimed to detect broad emission lines that could disprove this classification. In the obtained spectra, we do not detect any emission features and we provide an upper limit to the luminosity of the C IV broad emission line. Therefore, the nature of the object is then discussed, building the overall spectral energy distribution (SED) and fitting it with three different models. Our fits, based on SED modeling with different possible scenarios, cannot rule out the possibility that this source is indeed a BL Lac object, though the absence of optical variability and the lack of strong radio flux seem to suggest that the observed optical emission originates from a thermalized accretion disk.

  5. Fiber optic based optical tomography sensor for monitoring plasma uniformity

    International Nuclear Information System (INIS)

    Benck, Eric C.; Etemadi, Kasra

    2001-01-01

    A new type of fiber optic based optical tomography sensor has been developed for in situ monitoring of plasma uniformity. Optical tomography inverts optical emission measurements into the actual plasma distribution without assuming radial symmetry. The new sensor is designed to operate with only two small windows and acquire the necessary data in less than a second. Optical tomography is being tested on an ICP-GEC RF plasma source. Variations in plasma uniformity are measured as a function of different plasma conditions

  6. Chemical analysis by X-ray fluorescence, of niobium in high-strength plate steels

    International Nuclear Information System (INIS)

    Iozzi, F.B.; Dias, M.J.P.

    1981-01-01

    The use of X-ray fluorescence spectrometry in quantitative analysis of niobium in steels, as an alternative solution for optical emission spectrometry, in the rapid chemical control of steel fabrication by LD type converters, is presented. (M.C.K.) [pt

  7. Transient Infrared Emission Spectroscopy

    Science.gov (United States)

    Jones, Roger W.; McClelland, John F.

    1989-12-01

    Transient Infrared Emission Spectroscopy (TIRES) is a new technique that reduces the occurrence of self-absorption in optically thick solid samples so that analytically useful emission spectra may be observed. Conventional emission spectroscopy, in which the sample is held at an elevated, uniform temperature, is practical only for optically thin samples. In thick samples the emission from deep layers of the material is partially absorbed by overlying layers.1 This self-absorption results in emission spectra from most optically thick samples that closely resemble black-body spectra. The characteristic discrete emission bands are severely truncated and altered in shape. TIRES bypasses this difficulty by using a laser to heat only an optically thin surface layer. The increased temperature of the layer is transient since the layer will rapidly cool and thicken by thermal diffusion; hence the emission collection must be correlated with the laser heating. TIRES may be done with both pulsed and cw lasers.2,3 When a pulsed laser is used, the spectrometer sampling must be synchronized with the laser pulsing so that only emission during and immediately after each laser pulse is observed.3 If a cw laser is used, the sample must move rapidly through the beam. The hot, transient layer is then in the beam track on the sample at and immediately behind the beam position, so the spectrometer field of view must be limited to this region near the beam position.2 How much self-absorption the observed emission suffers depends on how thick the heated layer has grown by thermal diffusion when the spectrometer samples the emission. Use of a pulsed laser synchronized with the spectrometer sampling readily permits reduction of the time available for heat diffusion to about 100 acs .3 When a cw laser is used, the heat-diffusion time is controlled by how small the spectrometer field of view is and by how rapidly the sample moves past within this field. Both a very small field of view and a

  8. Sensoring fusion data from the optic and acoustic emissions of electric arcs in the GMAW-S process for welding quality assessment.

    Science.gov (United States)

    Alfaro, Sadek Crisóstomo Absi; Cayo, Eber Huanca

    2012-01-01

    The present study shows the relationship between welding quality and optical-acoustic emissions from electric arcs, during welding runs, in the GMAW-S process. Bead on plate welding tests was carried out with pre-set parameters chosen from manufacturing standards. During the welding runs interferences were induced on the welding path using paint, grease or gas faults. In each welding run arc voltage, welding current, infrared and acoustic emission values were acquired and parameters such as arc power, acoustic peaks rate and infrared radiation rate computed. Data fusion algorithms were developed by assessing known welding quality parameters from arc emissions. These algorithms have showed better responses when they are based on more than just one sensor. Finally, it was concluded that there is a close relation between arc emissions and quality in welding and it can be measured from arc emissions sensing and data fusion algorithms.

  9. Sensoring Fusion Data from the Optic and Acoustic Emissions of Electric Arcs in the GMAW-S Process for Welding Quality Assessment

    Directory of Open Access Journals (Sweden)

    Eber Huanca Cayo

    2012-05-01

    Full Text Available The present study shows the relationship between welding quality and optical-acoustic emissions from electric arcs, during welding runs, in the GMAW-S process. Bead on plate welding tests was carried out with pre-set parameters chosen from manufacturing standards. During the welding runs interferences were induced on the welding path using paint, grease or gas faults. In each welding run arc voltage, welding current, infrared and acoustic emission values were acquired and parameters such as arc power, acoustic peaks rate and infrared radiation rate computed. Data fusion algorithms were developed by assessing known welding quality parameters from arc emissions. These algorithms have showed better responses when they are based on more than just one sensor. Finally, it was concluded that there is a close relation between arc emissions and quality in welding and it can be measured from arc emissions sensing and data fusion algorithms.

  10. Evaluation of Optical Depths and Self-Absorption of Strontium and Aluminum Emission Lines in Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Alfarraj, Bader A; Bhatt, Chet R; Yueh, Fang Yu; Singh, Jagdish P

    2017-04-01

    Laser-induced breakdown spectroscopy (LIBS) is a widely used laser spectroscopic technique in various fields, such as material science, forensic science, biological science, and the chemical and pharmaceutical industries. In most LIBS work, the analysis is performed using radiative transitions from atomic emissions. In this study, the plasma temperature and the product [Formula: see text] (the number density N and the absorption path length [Formula: see text]) were determined to evaluate the optical depths and the self-absorption of Sr and Al lines. A binary mixture of strontium nitrate and aluminum oxide was used as a sample, consisting of variety of different concentrations in powder form. Laser-induced breakdown spectroscopy spectra were collected by varying various parameters, such as laser energy, gate delay time, and gate width time to optimize the LIBS signals. Atomic emission from Sr and Al lines, as observed in the LIBS spectra of different sample compositions, was used to characterize the laser induced plasma and evaluate the optical depths and self-absorption of LIBS.

  11. Determination of lithium and potassium in uranium oxide powders and pellets by Flame Atomic Emission Spectrometric method

    International Nuclear Information System (INIS)

    Jat, J.R.; Balaji Rao, Y.; Prasada Rao, G.; Prahlad, B.

    2012-01-01

    The present paper describes a method developed at Control Laboratory, NFC which includes prior separation of lithium and potassium from uranium matrix before their measurements. Solvent extraction, using Tri-n-Butyl Phosphate (TBP) in CCI 4 followed by Tri-n-Octyl Phosphine Oxide (TOPO) in CCI 4 , is employed for prior separation of Li and K. The resultant aqueous solution was analyzed by Flame-Atomic Emission Spectrometric (AES) method. Solvent extraction conditions are optimized for measurement of Li and K in the same aliquot. Experimental conditions such as instrument calibration, flame condition, fuel flow, sample flow rate through nebulizer, burner height etc. are also optimized. Under the optimal condition the detection limits achieved for lithium is 0.02 ppm and 0.2 ppm for potassium. A RSD of ± 3 % for Li at 0.05 ppm and ± 4% for K at 1 ppm level has been achieved in this method. The results of lithium in the sample are compared with the values obtained by Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES). Similarly, values of potassium are compared with Flame-Atomic Absorption Spectrometry (Flame-AAS) technique. The comparisons are in good agreement. The above method is simple, sensitive, reproducible and can be used for measurement of lithium and potassium in UO 2 powder and pellets on regular basis

  12. Teaching Diffraction with Hands-On Optical Spectrometry

    Science.gov (United States)

    Fischer, Robert

    2012-01-01

    Although the observation of optical spectra is common practice in physics classes, students are usually limited to a passive, qualitative observation of nice colours. This paper discusses a diffraction-based spectrometer that allows students to take quantitative measurements of spectral bands. Students can build it within minutes from generic…

  13. Dynamics, OH distributions and UV emission of a gliding arc at various flow-rates investigated by optical measurements

    International Nuclear Information System (INIS)

    Zhu, Jiajian; Sun, Zhiwei; Li, Zhongshan; Ehn, Andreas; Aldén, Marcus; Salewski, Mirko; Leipold, Frank; Kusano, Yukihiro

    2014-01-01

    We demonstrate a plasma discharge which is generated between two diverging electrodes and extended into a gliding arc in non-equilibrium condition by an air flow at atmospheric pressure. Effects of the air flow rates on the dynamics, ground-state OH distributions and spectral characterization of UV emission of the gliding arc were investigated by optical methods. High-speed photography was utilized to reveal flow-rate dependent dynamics such as ignitions, propagation, short-cutting events, extinctions and conversions of the discharge from glowtype to spark-type. Short-cutting events and ignitions occur more frequently at higher flow rates. The anchor points of the gliding arc are mostly steady at the top of the electrodes at lower flow rates whereas at higher flow rates they glide up along the electrodes most of the time. The afterglow of fully developed gliding arcs is observed to decay over hundreds of microseconds after being electronically short-cut by a newly ignited arc. The extinction time decreases with the increase of the flow rate. The frequency of the conversion of a discharge from glow-type to spark-type increases with the flow rate. Additionally, spatial distributions of ground-state OH were investigated using planar laser-induced fluorescence. The results show that the shape, height, intensity and thickness of ground-state OH distribution vary significantly with air flow rates. Finally, UV emission of the gliding arc is measured using optical emission spectroscopy and it is found that the emission intensity of NO γ (A-X), OH (A-X) and N 2 (C-B) increase with the flow rates showing more characteristics of spark-type arcs. The observed phenomena indicate the significance of the interaction between local turbulence and the gliding arc. (paper)

  14. Dynamics, OH distributions and UV emission of a gliding arc at various flow-rates investigated by optical measurements

    Science.gov (United States)

    Zhu, Jiajian; Sun, Zhiwei; Li, Zhongshan; Ehn, Andreas; Aldén, Marcus; Salewski, Mirko; Leipold, Frank; Kusano, Yukihiro

    2014-07-01

    We demonstrate a plasma discharge which is generated between two diverging electrodes and extended into a gliding arc in non-equilibrium condition by an air flow at atmospheric pressure. Effects of the air flow rates on the dynamics, ground-state OH distributions and spectral characterization of UV emission of the gliding arc were investigated by optical methods. High-speed photography was utilized to reveal flow-rate dependent dynamics such as ignitions, propagation, short-cutting events, extinctions and conversions of the discharge from glowtype to spark-type. Short-cutting events and ignitions occur more frequently at higher flow rates. The anchor points of the gliding arc are mostly steady at the top of the electrodes at lower flow rates whereas at higher flow rates they glide up along the electrodes most of the time. The afterglow of fully developed gliding arcs is observed to decay over hundreds of microseconds after being electronically short-cut by a newly ignited arc. The extinction time decreases with the increase of the flow rate. The frequency of the conversion of a discharge from glow-type to spark-type increases with the flow rate. Additionally, spatial distributions of ground-state OH were investigated using planar laser-induced fluorescence. The results show that the shape, height, intensity and thickness of ground-state OH distribution vary significantly with air flow rates. Finally, UV emission of the gliding arc is measured using optical emission spectroscopy and it is found that the emission intensity of NO γ (A-X), OH (A-X) and N2 (C-B) increase with the flow rates showing more characteristics of spark-type arcs. The observed phenomena indicate the significance of the interaction between local turbulence and the gliding arc.

  15. Space-resolved characterization of high frequency atmospheric-pressure plasma in nitrogen, applying optical emission spectroscopy and numerical simulation

    International Nuclear Information System (INIS)

    Rajasekaran, Priyadarshini; Ruhrmann, Cornelia; Bibinov, Nikita; Awakowicz, Peter

    2011-01-01

    Averaged plasma parameters such as electron distribution function and electron density are determined by characterization of high frequency (2.4 GHz) nitrogen plasma using both experimental methods, namely optical emission spectroscopy (OES) and microphotography, and numerical simulation. Both direct and step-wise electron-impact excitation of nitrogen emissions are considered. The determination of space-resolved electron distribution function, electron density, rate constant for electron-impact dissociation of nitrogen molecule and the production of nitrogen atoms, applying the same methods, is discussed. Spatial distribution of intensities of neutral nitrogen molecule and nitrogen molecular ion from the microplasma is imaged by a CCD camera. The CCD images are calibrated using the corresponding emissions measured by absolutely calibrated OES, and are then subjected to inverse Abel transformation to determine space-resolved intensities and other parameters. The space-resolved parameters are compared, respectively, with the averaged parameters, and an agreement between them is established. (paper)

  16. Assembly of positioner of automated two-dimensional scan coupled to X-ray fluorescence spectrometry; Montagem de posicionador de varredura bidimensional automatizada acoplado a espectrometria de fluorescência de raios-X

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Leonardo Santiago Melgaço

    2011-07-01

    This work describes the design and assembling of a prototype automated positioner two-dimensional scanning coupled to X-ray fluorescence spectrometry. The work aims to achieve a portable and easy to use, device of broad utility in the analysis of samples by X-ray fluorescence area of expertise and research. The two-dimensional scanning of the positioner is by means of two stepper motors controlled by a microcontroller PIC 16F877A, encoder and optical sensors. The user interacts with the XY table through an interface program for the Windows operating system, which communicates with the microcontroller through the serial port. The system of Fluorescence Spectroscopy incorporated into the positioner consists of a system commercially available system from the company AMPTEK, where the primary source of excitation of the sample was a source of {sup 241}Am of 59.5 KeV emissions. Resolution and accuracy of tests were performed in the XY scanning process and reproducibility of the same kit with the fluorescence spectrometry X-ray. Qualitative tests by X-ray fluorescence spectrometry in samples were performed to demonstrate the applicability and versatility of the project. It follows that the prototype illustrates a possible adequately to portable device for X-ray spectrometry of two-dimensional. (author)

  17. Composition of Renaissance paint layers: simultaneous particle induced X-ray emission and backscattering spectrometry.

    Science.gov (United States)

    de Viguerie, L; Beck, L; Salomon, J; Pichon, L; Walter, Ph

    2009-10-01

    Particle induced X-ray emission spectroscopy (PIXE) is now routinely used in the field of cultural heritage. Various setups have been developed to investigate the elemental composition of wood/canvas paintings or of cross-section samples. However, it is not possible to obtain information concerning the quantity of organic binder. Backscattering spectrometry (BS) can be a useful complementary method to overcome this limitation. In the case of paint layers, PIXE brings the elemental composition (major elements to traces) and the BS spectrum can give access to the proportion of pigment and binder. With the use of 3 MeV protons for PIXE and BS simultaneously, it was possible to perform quantitative analysis including C and O for which the non-Rutherford cross sections are intense. Furthermore, with the use of the same conditions for PIXE and BS, the experiment time and the potential damage by the ion beam were reduced. The results obtained with the external beam of the Accélérateur Grand Louvre pour l'Analyse Elementaire (AGLAE) facility on various test painting samples and on cross sections from Italian Renaissance masterpieces are shown. Simultaneous combination of PIXE and BS leads to a complete characterization of the paint layers: elemental composition and proportion of the organic binder have been determined and thus provide useful information about ancient oil painting recipes.

  18. Spectrochemical determination of tantalum in plutonium metal using direct current plasma emission spectrometry

    International Nuclear Information System (INIS)

    Fadeff, S.K.; Morris, W.F.

    1983-01-01

    Tantalum is determined by direct current plasma spectrometry after separation of plutonium from solution as PuF 3 . After centrifugation of the PuF 3 precipitate, a low level of plutonium remains in solution in sufficient quantity to cause spectral interferences. It is necessary to determine the plutonium by dc plasma spectrometry and apply a correction to determine low tantalum concentrations with good accuracy and precision. Tantalum can be determined down to 0.4 ppM in solution with a relative standard deviation of 10 percent. Better precision can be achieved at higher concentrations. The procedure is simple and convenient for glovebox work. 5 references, 1 figure, 1 table

  19. On the expression 'external calibration' in atomic spectrometry

    International Nuclear Information System (INIS)

    Kantor, Tibor

    2008-01-01

    The expressions 'calibration' and 'external calibration' appear together in the present literature of atomic spectrometry resulting in a dilemma of understanding and correct use. It is examined how the IUPAC can provide a guidance to the solution of this problem by recalling the definitions of related terms of optical, mass and X-ray atomic spectrometry techniques. The introduction and definition of these expressions in widely used text books are investigated and statistically evaluated for the articles published during the last 30 years in the periodical Spectrochimica Acta Part B. For the elimination of the literary difficulties with the use of the term 'calibration', attributes are proposed to express the degree of matrix matching of standards and samples

  20. NuSTAR OBSERVATIONS OF GRB 130427A ESTABLISH A SINGLE COMPONENT SYNCHROTRON AFTERGLOW ORIGIN FOR THE LATE OPTICAL TO MULTI-GEV EMISSION

    International Nuclear Information System (INIS)

    Kouveliotou, C.; Granot, J.; Racusin, J. L.; Gehrels, N.; McEnery, J. E.; Zhang, W. W.; Bellm, E.; Harrison, F. A.; Vianello, G.; Oates, S.; Fryer, C. L.; Boggs, S. E.; Craig, W. W.; Christensen, F. E.; Dermer, C. D.; Hailey, C. J.; Melandri, A.; Tagliaferri, G.; Mundell, C. G.; Stern, D. K.

    2013-01-01

    GRB 130427A occurred in a relatively nearby galaxy; its prompt emission had the largest GRB fluence ever recorded. The afterglow of GRB 130427A was bright enough for the Nuclear Spectroscopic Telescope ARray (NuSTAR) to observe it in the 3-79 keV energy range long after its prompt emission (∼1.5 and 5 days). This range, where afterglow observations were previously not possible, bridges an important spectral gap. Combined with Swift, Fermi, and ground-based optical data, NuSTAR observations unambiguously establish a single afterglow spectral component from optical to multi-GeV energies a day after the event, which is almost certainly synchrotron radiation. Such an origin of the late-time Fermi/Large Area Telescope >10 GeV photons requires revisions in our understanding of collisionless relativistic shock physics

  1. Optical luminescence from alkyl-passivated Si nanocrystals under vacuum ultraviolet excitation: Origin and temperature dependence of the blue and orange emissions

    OpenAIRE

    Chao, Y; Houlton, A; Horrocks, BR; Hunt, MRC; Poolton, NRJ; Yang, J; Šiller, L

    2006-01-01

    The origin and stability of luminescence are critical issues for Si nanocrystals which are intended for use as biological probes. The optical luminescence of alkyl-monolayer-passivated silicon nanocrystals was studied under excitation with vacuum ultraviolet photons (5.1–23 eV). Blue and orange emission bands were observed simultaneously, but the blue band only appeared at low temperatures (8.7 eV). At 8 K, the peak wavelengths of the emission bands were 430±2 nm (blue) and 600±2 nm (orange)....

  2. All-optical signatures of strong-field QED in the vacuum emission picture

    Science.gov (United States)

    Gies, Holger; Karbstein, Felix; Kohlfürst, Christian

    2018-02-01

    We study all-optical signatures of the effective nonlinear couplings among electromagnetic fields in the quantum vacuum, using the collision of two focused high-intensity laser pulses as an example. The experimental signatures of quantum vacuum nonlinearities are encoded in signal photons, whose kinematic and polarization properties differ from the photons constituting the macroscopic laser fields. We implement an efficient numerical algorithm allowing for the theoretical investigation of such signatures in realistic field configurations accessible in experiment. This algorithm is based on a vacuum emission scheme and can readily be adapted to the collision of more laser beams or further involved field configurations. We solve the case of two colliding pulses in full 3 +1 -dimensional spacetime and identify experimental geometries and parameter regimes with improved signal-to-noise ratios.

  3. Mercury determination in non- and biodegradable materials by cold vapor capacitively coupled plasma microtorch atomic emission spectrometry.

    Science.gov (United States)

    Frentiu, Tiberiu; Mihaltan, Alin I; Ponta, Michaela; Darvasi, Eugen; Frentiu, Maria; Cordos, Emil

    2011-10-15

    A new analytical system consisting of a low power capacitively coupled plasma microtorch (20 W, 13.56 MHz, 150 ml min(-1) Ar) and a microspectrometer was investigated for the Hg determination in non- and biodegradable materials by cold-vapor generation, using SnCl(2) reductant, and atomic emission spectrometry. The investigated miniaturized system was used for Hg determination in recyclable plastics from electronic equipments and biodegradable materials (shopping bags of 98% biodegradable polyethylene and corn starch) with the advantages of easy operation and low analysis costs. Samples were mineralized in HNO(3)-H(2)SO(4) mixture in a high-pressure microwave system. The detection limits of 0.05 ng ml(-1) or 0.08 μg g(-1) in solid sample were compared with those reported for other analytical systems. The method precision was 1.5-9.4% for Hg levels of 1.37-13.9 mg kg(-1), while recovery in two polyethylene certified reference materials in the range 98.7 ± 4.5% (95% confidence level). Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Combined optical emission and resonant absorption diagnostics of an Ar-O{sub 2}-Ce-reactive magnetron sputtering discharge

    Energy Technology Data Exchange (ETDEWEB)

    El Mel, A.A. [Chimie des Interactions Plasma-Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, Place du Parc 23, Mons B-7000 (Belgium); Institut des Matériaux Jean Rouxel, Université de Nantes, CNRS, 2 rue de la Houssinière B.P. 32229, Nantes Cedex 3 44322 (France); Ershov, S. [Chimie des Interactions Plasma-Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, Place du Parc 23, Mons B-7000 (Belgium); Britun, N., E-mail: nikolay.britun@umons.ac.be [Chimie des Interactions Plasma-Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, Place du Parc 23, Mons B-7000 (Belgium); Ricard, A. [Université de Toulouse, UPS, INPT, LAPLACE (Laboratoire Plasma et Conversion d' Energie), 118 route de Narbonne, Toulouse Cedex 9 F-31062 (France); Konstantinidis, S. [Chimie des Interactions Plasma-Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, Place du Parc 23, Mons B-7000 (Belgium); Snyders, R. [Chimie des Interactions Plasma-Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, Place du Parc 23, Mons B-7000 (Belgium); Materia Nova Research Center, Parc Initialis, Avenue Copernic 1, Mons B-7000 (Belgium)

    2015-01-01

    We report the results on combined optical characterization of Ar-O{sub 2}-Ce magnetron sputtering discharges by optical emission and resonant absorption spectroscopy. In this study, a DC magnetron sputtering system equipped with a movable planar magnetron source with a Ce target is used. The intensities of Ar, O, and Ce emission lines, as well as the absolute densities of Ar metastable and Ce ground state atoms are analyzed as a function of the distance from the magnetron target, applied DC power, O{sub 2} content, etc. The absolute number density of the Ar{sup m} is found to decrease exponentially as a function of the target-to-substrate distance. The rate of this decrease is dependent on the sputtering regime, which should be due to the different collisional quenching rates of Ar{sup m} by O{sub 2} molecules at different oxygen contents. Quantitatively, the absolute number density of Ar{sup m} is found to be equal to ≈ 3 × 10{sup 8} cm{sup −3} in the metallic, and ≈ 5 × 10{sup 7} cm{sup −3} in the oxidized regime of sputtering, whereas Ce ground state densities at the similar conditions are found to be few times lower. The absolute densities of species are consistent with the corresponding deposition rates, which decrease sharply during the transition from metallic to poisoned sputtering regime. - Highlights: • Optical emission and resonant absorption spectroscopy are employed to study Ar-O{sub 2}-Ce magnetron sputtering discharges. • The density of argon metastables is found to decrease exponentially when increasing the target-to-substrate distance. • The collision-quenching rates of Ar{sup m} by O{sub 2} molecules at different oxygen contents is demonstrated. • The deposition rates of cerium and cerium oxide thin films decrease sharply during the transition from the metallic to the poisoned sputtering regime.

  5. Characterization of rapidly-prototyped, battery-operated, argon-hydrogen microplasma on a hybrid chip for elemental analysis of microsamples by portable optical emission spectrometry

    International Nuclear Information System (INIS)

    Weagant, Scott; Dulai, Gurjit; Li, Lu; Karanassios, Vassili

    2015-01-01

    A rapidly-prototyped, battery-operated, atmospheric-pressure, self-igniting Ar-H 2 microplasma was interfaced to a portable fiber-optic spectrometer. The microplasma-spectrometer combination was used to document the spectral lines emitted when μL of dilute solutions of single element standards of Ag, Ba, Ca, Eu, Pd, Rb and Sr were first dried and then vaporized into the microplasma. A small-size, electrothermal vaporization system was used for microsample introduction. Identification of the prominent spectral lines for these elements is reported. It was found that the most prominent spectral line for Ba, Ca and Sr was different than that emitted from an inductively coupled plasma (ICP). In general, prominent spectral lines with low excitation energy were dominating, thus resulting in spectra simpler than those emitted from an ICP. Detection limits were between 45 and 180 pg (expressed in absolute amounts). When expressed in relative concentration units, they ranged between 15 and 60 μg/L (obtained using 3 μL diluted standards). Calibration curves were linear (on the average) for 1.5 orders-of-magnitude. Average precision was 15%. Analytical capability and utility was demonstrated using the determination of Ca and Mg in (medicinal) thermal spring water. - Highlights: • Microplasma emission spectra for Ag, Ba, Ca, Eu, Pd, Rb and Sr are reported. • Absolute amount detection limits ranged between 45 pg and 180 pg. • Relative unit detection limits ranged between 15 and 60 μg/L (using 3 μL). • The effect of vaporization temperature on analyte signals is reported. • Ca and Mg concentrations in (medicinal) thermal spring water were determined

  6. Characterization of rapidly-prototyped, battery-operated, argon-hydrogen microplasma on a hybrid chip for elemental analysis of microsamples by portable optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Weagant, Scott; Dulai, Gurjit; Li, Lu; Karanassios, Vassili, E-mail: vkaranassios@uwaterloo.ca

    2015-04-01

    A rapidly-prototyped, battery-operated, atmospheric-pressure, self-igniting Ar-H{sub 2} microplasma was interfaced to a portable fiber-optic spectrometer. The microplasma-spectrometer combination was used to document the spectral lines emitted when μL of dilute solutions of single element standards of Ag, Ba, Ca, Eu, Pd, Rb and Sr were first dried and then vaporized into the microplasma. A small-size, electrothermal vaporization system was used for microsample introduction. Identification of the prominent spectral lines for these elements is reported. It was found that the most prominent spectral line for Ba, Ca and Sr was different than that emitted from an inductively coupled plasma (ICP). In general, prominent spectral lines with low excitation energy were dominating, thus resulting in spectra simpler than those emitted from an ICP. Detection limits were between 45 and 180 pg (expressed in absolute amounts). When expressed in relative concentration units, they ranged between 15 and 60 μg/L (obtained using 3 μL diluted standards). Calibration curves were linear (on the average) for 1.5 orders-of-magnitude. Average precision was 15%. Analytical capability and utility was demonstrated using the determination of Ca and Mg in (medicinal) thermal spring water. - Highlights: • Microplasma emission spectra for Ag, Ba, Ca, Eu, Pd, Rb and Sr are reported. • Absolute amount detection limits ranged between 45 pg and 180 pg. • Relative unit detection limits ranged between 15 and 60 μg/L (using 3 μL). • The effect of vaporization temperature on analyte signals is reported. • Ca and Mg concentrations in (medicinal) thermal spring water were determined.

  7. Pyrolysis gas chromatographic atomic emission detection for sediments, coals and other petrochemical precursors

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, J.A.; Zeng, Y.D.; Uden, P.C.; Eglinton, T.I.; Ericson, I. (Massachusetts University, Amherst, MA (USA). Dept. of Chemistry)

    1992-09-01

    On-line flash pyrolysis coupled to a capillary gas chromatograph for the characterization of marine sediments, coals and other heterogeneous solid samples is described. A helium microwave-induced plasma is used for chromatographic detection by atomic emission spectrometry. Simultaneous multi-element detection is achieved with a photodiode array detector. The optical path of the gas chromatographic atomic emission detector is purged with helium, allowing simultaneous, sensitive detection of atomic emission from sulfur 181 nm, phosphorous 186 nm, arsenic 189 nm, selenium 196 nm and carbon 193 nm. Several sediment and coal samples have been analysed for their carbon, nitrogen, sulfur, oxygen, phosphorous, arsenic and selenium content. Qualitative information indicating the occurrence and distribution of these elements in the samples can be used to gauge the relative stage of diagenetic evolution of the samples and provide information on their depositional environment. In some instances the chromatographic behaviour of the compounds produced upon pyrolysis is improved through on-line alkylation. This on-line derivatization is achieved by adding liquid reagents to the pyrolysis probe or by adding liquid reagents to the pyrolysis probe or by adding solid reagents either to the solid sample or by packing the reagent in the injection port of the chromatograph.

  8. Laser terahertz emission microscopy with near-field probes

    DEFF Research Database (Denmark)

    Pedersen, Pernille Klarskov; Mittleman, Daniel M.

    2016-01-01

    Using an AFM, an optical near-field image at 800 nm of a dipole antenna for THz emission is measured, and by simultaneously collecting the emitted THz radiation, the laser light confined under the AFM probe gives a THz emission resolution of less than 50 nm.......Using an AFM, an optical near-field image at 800 nm of a dipole antenna for THz emission is measured, and by simultaneously collecting the emitted THz radiation, the laser light confined under the AFM probe gives a THz emission resolution of less than 50 nm....

  9. Analysis of sample γ-spectrometry with mathematic simulating

    International Nuclear Information System (INIS)

    Guo Hongsheng; He Xijun; Peng Taiping; Yang Gaozhao; Wang Wenchuan; Feng Chun

    2005-01-01

    When a sample contains various energy γ-rays, its peak area records not only the events of optical-electronic effect but also the Compton scattering events of higher energy γ-rays. So the γ-ray intensity conducted by the peak area can not be gained. Using the anti-matrix method, the better results of analysis on the γ-spectrometry can be obtained. (authors)

  10. A new atomization cell for trace metal determinations by tungsten coil atomic spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Donati, G.L., E-mail: georgedonati@yahoo.com.br [Department of Chemistry, Wake Forest University, Winston-Salem, NC 27109 (United States); Wildman, R.B.; Jones, B.T. [Department of Chemistry, Wake Forest University, Winston-Salem, NC 27109 (United States)

    2011-02-28

    A new metallic atomization cell is used for trace metal determinations by tungsten coil atomic absorption spectrometry and tungsten coil atomic emission spectrometry. Different protecting gas mixtures are evaluated to improve atomic emission signals. Ar, N{sub 2}, CO{sub 2} and He are used as solvents, and H{sub 2} and C{sub 2}H{sub 2} as solutes. A H{sub 2}/Ar mixture provided the best results. Parameters such as protecting gas flow rate and atomization current are also optimized. The optimal conditions are used to determine the figures of merit for both methods and the results are compared with values found in the literature. The new cell provides a better control of the radiation reaching the detector and a small, more isothermal environment around the atomizer. A more concentrated atomic cloud and a smaller background signal result in lower limits of detection using both methods. Cu (324.7 nm), Cd (228.8 nm) and Sn (286.3 nm) determined by tungsten coil atomic absorption spectrometry presented limits of detection as low as 0.6, 0.1, and 2.2 {mu}g L{sup -1}, respectively. For Cr (425.4 nm), Eu (459.4 nm) and Sr (460.7 nm) determined by tungsten coil atomic emission spectrometry, limits of detection of 4.5, 2.5, and 0.1 {mu}g L{sup -1} were calculated. The method is used to determine Cu, Cd, Cr and Sr in a water standard reference material. Results for Cu, Cd and Cr presented no significant difference from reported values in a 95% confidence level. For Sr, a 113% recovery was obtained.

  11. Environmental atmospheric impact assessment by the emission of particles in an industrial area

    International Nuclear Information System (INIS)

    Gomez, Dario R.; Ledesma, Ariel G.; Vazquez, Cristina; Smichowski, Patricia N.; Romero, Carlos A.; Dawidowski, Laura E.; Ortiz, Maria; Marrero, Julieta G.

    1999-01-01

    The content of metals present in suspended particulate matter was evaluated using analytical related nuclear techniques, in order to discriminate the contribution of different emission sources to the atmospheric concentration in the area of Campana, located in the Province of Buenos Aires. The levels of Ti, V, Cr, Mn, Ni, Cu, Zn, Sr, Ag, Cd y Pb were quantified by Wave Dispersion X-Ray Florescence spectrometry (WDXRF), Total Reflection X-Ray Fluorescence spectrometry (TRXRF) and Inducted Coupled Plasma Absorption Emission spectroscopy (ICP-AES). (author)

  12. Depth-profile analysis of thermoelectric layers on Si wafers by pulsed r.f. glow discharge time-of-flight mass spectrometry

    International Nuclear Information System (INIS)

    Reinsberg, K.-G.; Schumacher, C.; Tempez, A.; Nielsch, K.; Broekaert, J.A.C.

    2012-01-01

    In this work the depth-profile analysis of thermoelectric layers deposited on Au and Cr covered Si wafers with the aid of pulsed radiofrequency glow discharge time-of-flight mass spectrometry (pulsed RF-GD-TOFMS also called plasma profiling TOFMS (PP-TOFMS™)) is described. For thermoelectric materials the depth resolutions obtained with both PP-TOFMS and secondary ion mass spectrometry (SIMS) are shown to be well comparable and in the order of the roughness of the corresponding layers (between 20 and 3700 nm). With both methods a direct solid analysis without any preparation steps is possible. In addition, the analysis of the samples with PP-TOFMS proved to be faster by a factor of 26 compared to SIMS, as sputtering rates were found to be 80 nm s −1 and 3 nm s −1 , respectively. For the analyzed samples the results of PP-TOFMS and SIMS show that a homogeneous deposition was obtained. Quantitative results for all samples could also be obtained directly by PP-TOFMS when the stoichiometry of one sample was determined beforehand for instance by inductively coupled plasma optical emission spectrometry (ICP-OES) and scanning electron microscopy energy dispersive X-ray fluorescence spectrometry (SEM-EDX). For Bi 2 Te 3 the standard deviation for the main component concentrations within one sample then is found to be between 1.1% and 1.9% and it is 3.6% from sample to sample. For Sb 2 Te 3 the values within one sample are from 1.7% to 4.2% and from sample to sample 5.3%, respectively. - Highlights: ► Depth resolution in sub micrometer size by glow discharge mass spectrometry. ► Bi and Sb telluride layers composition with GD-TOF-MS, ICP-OES and SEM-EDX agree. ► Homogeneities of layers measured with GD-TOF-MS and SIMS agree.

  13. Solid phase microextraction capillary gas chromatography combined with furnace atomization plasma emission spectrometry for speciation of mercury in fish tissues

    International Nuclear Information System (INIS)

    Grinberg, Patricia; Campos, Reinaldo C.; Mester, Zoltan; Sturgeon, Ralph E.

    2003-01-01

    The use of solid phase microextraction in conjunction with tandem gas chromatography-furnace atomization plasma emission spectrometry (SPME-GC-FAPES) was evaluated for the determination of methylmercury and inorganic mercury in fish tissue. Samples were digested with methanolic potassium hydroxide, derivatized with sodium tetraethylborate and extracted by SPME. After the SPME extraction, species were separated by GC and detected by FAPES. All experimental parameters were optimized for best separation and analytical response. A repeatability precision of typically 2% can be achieved with long-term (3 months) reproducibility precision of 4.3%. Certified Reference Materials DORM-2, DOLT-2 and TORT-2 from the National Research Council of Canada were analyzed to verify the accuracy of this technique. Detection limits of 1.5 ng g -1 for methylmercury and 0.7 ng g -1 for inorganic mercury in biological tissues were obtained

  14. Tomography feasibility study on the optical emission spectroscopy diagnostic for the negative ion source of the ELISE test facility

    International Nuclear Information System (INIS)

    Bonomo, F; Agostini, M; Brombin, M; Pasqualotto, R; Fantz, U; Franzen, P; Wünderlich, D

    2014-01-01

    A feasibility study of a spectroscopic tomographic diagnostic for the emissivity reconstruction of the plasma parameters in the large negative ion source of the test facility ELISE is described. Tomographic tools are developed to be applied to the measurements of the ELISE optical emission spectroscopy (OES) diagnostic, in order to reconstruct the emissivity distribution from hydrogen (or deuterium) plasma close to the plasma grid, where negative ions are produced and extracted to be accelerated. Various emissivity phantoms, both symmetric and asymmetric, reproducing different plasma experimental conditions have been simulated to test the tomographic algorithm. The simultaneous algebraic reconstruction technique has been applied, accounting for the OES geometrical layout together with a suitable pixel representation. Even with a limited number of 14 lines of sight (LoSs), the plasma emissivity distribution expected on the ELISE source can be successfully reconstructed. In particular, asymmetries in the emissivity pattern can be detected and reproduced with low errors. A systematic investigation of different geometrical layouts of the LoSs as well as of the pixel arrangements has been carried out, and a final configuration has been identified. Noise on the simulated experimental spectroscopic measurements has been tested, confirming the reliability of the adopted tomographic tools for the plasma emissivity reconstructions of the source plasma in ELISE with the actual OES diagnostic system. (paper)

  15. Ion detection in mass spectrometry

    International Nuclear Information System (INIS)

    Bolbach, Gerard

    2016-03-01

    This course aims at providing some elements for a better understanding of ion detectors used in mass spectrometers, of their operations, and of their limitations. A first part addresses the functions and properties of an ideal detector, how to detect ions in gas phase, and particle detectors and ion detectors used in mass spectrometry. The second part proposes an overview of currently used detectors with respect to their operation principle: detection from the ion charge (Faraday cylinder), detection by inductive effects (FTICR, Fourier Transform Ion Cyclotron Resonance), and detection by secondary electron emission. The third part discusses the specificities of secondary electron emission. The fourth one addresses operating modes and parameters related to detectors. The sixth part proposes a prospective view on future detectors by addressing the following issues: cryo-detector, inductive effect and charge detectors, ion detection and nano materials

  16. Ion-induced secondary electron emission, optical and hydration resistant behavior of MgO, Mg–Mo–O and Mg–Ce–O thin films

    International Nuclear Information System (INIS)

    Kumar, Ashok; Thota, Subhash; Deva, Dinesh; Kumar, Jitendra

    2014-01-01

    Optical transmittance, hydration resistance and secondary electron emission characteristics of e-beam evaporated pure and Mo- or Ce-containing MgO thin films have been investigated. While the increased grain size and pyramidal columnar morphology following incorporation of molybdenum and cerium in MgO are responsible for the excellent discharge characteristics, emergence of neutral {100} and {110} MgO surfaces preferentially give rise to high optical transmittance (∼ 92–100%) and stability against hydration. Further, addition of Mo (or Ce) in MgO causes significant increase in defect density which, in turn, enhances the photoluminescence (PL) emission from 5-, 4- and 3-coordination sites. The changes lead to lowering of the breakdown voltage and hence improvement in the secondary electron emission (SEE) efficiency. These facts have been supported by ion-induced SEE yield (γ) deduced from the a.c. breakdown voltage observed, taking neon as a discharge gas, and determined semi-empirically as well with Hagstrum's theory based on Auger neutralization process using (i) band offset parameters and surface band gap data derived from X-ray photoelectron spectroscopy signal and (ii) information of defect energy levels obtained from photoluminescence (PL) measurements. The experimental values of neon ion-induced SEE yield (γ) are found to be 0.35, 0.42 and 0.39 for MgO, Mg–Mo–O (x = 0.035) and Mg–Ce–O (x = 0.01) thin films, respectively. - Highlights: • Higher hydration resistance • Increased photoluminescence emission • Higher secondary electron emission

  17. Use of oxidative and reducing vapor generation for reducing the detection limits of iodine in biological samples by inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Vtorushina, Eh.A.; Saprykin, A.I.; Knapp, G.

    2009-01-01

    Procedures of microwave combustion in an oxygen flow and microwave acid decomposition of biological samples were optimized for the subsequent determination of iodine. A new method was proposed for the generation of molecular iodine from periodate iona using hydrogen peroxide as a reductant. Procedures were developed for determining iodine in biological samples by inductively coupled plasma atomic emission spectrometry (ICP-AES) using oxidative and reducing vapor generation; these allowed the detection limit for iodine to be lowered by 3-4 orders of magnitude. The developed procedures were used to analyze certified reference materials of milk (Skim Milk Powder BCR 150) and seaweed (Sea Lettuce BCR 279) and a Supradyn vitamin complex

  18. OPTICAL SPECTROSCOPY OF SDSS J004054.65-0915268: THREE POSSIBLE SCENARIOS FOR THE CLASSIFICATION. A z ∼ 5 BL LACERTAE, A BLUE FSRQ, OR A WEAK EMISSION LINE QUASAR

    International Nuclear Information System (INIS)

    Landoni, M.; Zanutta, A.; Bianco, A.; Tavecchio, F.; Bonnoli, G.; Ghisellini, G.

    2016-01-01

    The haunt of high-redshift BL Lacerate objects is day by day more compelling to firmly understand their intrinsic nature and evolution. SDSS J004054.65-0915268 is, at the moment, one of the most distant BL Lac candidates, at z ∼ 5. We present a new optical-near-IR spectrum obtained with ALFOSC-NOT with a new, custom designed dispersive grating aimed to detect broad emission lines that could disprove this classification. In the obtained spectra, we do not detect any emission features and we provide an upper limit to the luminosity of the C iv broad emission line. Therefore, the nature of the object is then discussed, building the overall spectral energy distribution (SED) and fitting it with three different models. Our fits, based on SED modeling with different possible scenarios, cannot rule out the possibility that this source is indeed a BL Lac object, though the absence of optical variability and the lack of strong radio flux seem to suggest that the observed optical emission originates from a thermalized accretion disk

  19. Spontaneous emission control in a tunable hybrid photonic system

    NARCIS (Netherlands)

    Frimmer, M.; Koenderink, A.F.

    2013-01-01

    We experimentally demonstrate control of the rate of spontaneous emission in a tunable hybrid photonic system that consists of two canonical building blocks for spontaneous emission control, an optical antenna and a mirror, each providing a modification of the local density of optical states (LDOS).

  20. LIMITS ON OPTICAL POLARIZATION DURING THE PROMPT PHASE OF GRB 140430A

    Energy Technology Data Exchange (ETDEWEB)

    Kopac, D.; Mundell, C. G.; Arnold, D. M.; Steele, I. A.; Kobayashi, S.; Lamb, G. P.; Smith, R. J.; Virgili, F. J. [Astrophysics Research Institute, Liverpool John Moores University, 146 Brownlow Hill, Liverpool, L3 5RF (United Kingdom); Japelj, J.; Gomboc, A. [Department of Physics, Faculty of Mathematics and Physics, University of Ljubljana, Jadranska 19, 1000 Ljubljana (Slovenia); Guidorzi, C.; Dichiara, S. [Department of Physics and Earth Sciences, University of Ferrara, via Saragat 1, I-44122, Ferrara (Italy); Harrison, R. M. [Department of Astrophysics, School of Physics and Astronomy, Tel Aviv University, 69978 Tel Aviv (Israel); Melandri, A. [INAF—Osservatorio Astronomico di Brera, via E. Bianchi 46, I-23807 Merate (Italy); Castro-Tirado, A. J.; Gorosabel, J.; Sánchez-Ramírez, R.; Oates, S. R. [Instituto de Astrofísica de Andalucía (IAA-CSIC), Glorieta de la Astronomia s/n, E-18008 Granada (Spain); Järvinen, A. [AIP—Leibniz-Institut für Astrophysik Potsdam, An der Sternwarte 16, D-14482 Potsdam (Germany); Jelínek, M., E-mail: drejc.kopac@fmf.uni-lj.si [ASU-CAS—Astronomical Institute of the Czech Academy of Sciences, Fričova 298, 251 65 Ondřejov (Czech Republic)

    2015-11-01

    Gamma-ray burst GRB 140430A was detected by the Swift satellite and observed promptly with the imaging polarimeter RINGO3 mounted on the Liverpool Telescope, with observations beginning while the prompt γ-ray emission was still ongoing. In this paper, we present densely sampled (10-s temporal resolution) early optical light curves (LCs) in 3 optical bands and limits to the degree of optical polarization. We compare optical, X-ray, and gamma-ray properties and present an analysis of the optical emission during a period of high-energy flaring. The complex optical LC cannot be explained merely with a combination of forward and reverse shock emission from a standard external shock, implying additional contribution of emission from internal shock dissipation. We estimate an upper limit for time averaged optical polarization during the prompt phase to be as low as P < 12% (1σ). This suggests that the optical flares and early afterglow emission in this GRB are not highly polarized. Alternatively, time averaging could mask the presence of otherwise polarized components of distinct origin at different polarization position angles.

  1. LIMITS ON OPTICAL POLARIZATION DURING THE PROMPT PHASE OF GRB 140430A

    International Nuclear Information System (INIS)

    Kopac, D.; Mundell, C. G.; Arnold, D. M.; Steele, I. A.; Kobayashi, S.; Lamb, G. P.; Smith, R. J.; Virgili, F. J.; Japelj, J.; Gomboc, A.; Guidorzi, C.; Dichiara, S.; Harrison, R. M.; Melandri, A.; Castro-Tirado, A. J.; Gorosabel, J.; Sánchez-Ramírez, R.; Oates, S. R.; Järvinen, A.; Jelínek, M.

    2015-01-01

    Gamma-ray burst GRB 140430A was detected by the Swift satellite and observed promptly with the imaging polarimeter RINGO3 mounted on the Liverpool Telescope, with observations beginning while the prompt γ-ray emission was still ongoing. In this paper, we present densely sampled (10-s temporal resolution) early optical light curves (LCs) in 3 optical bands and limits to the degree of optical polarization. We compare optical, X-ray, and gamma-ray properties and present an analysis of the optical emission during a period of high-energy flaring. The complex optical LC cannot be explained merely with a combination of forward and reverse shock emission from a standard external shock, implying additional contribution of emission from internal shock dissipation. We estimate an upper limit for time averaged optical polarization during the prompt phase to be as low as P < 12% (1σ). This suggests that the optical flares and early afterglow emission in this GRB are not highly polarized. Alternatively, time averaging could mask the presence of otherwise polarized components of distinct origin at different polarization position angles

  2. Experimental measurements of competition between fundamental and second harmonic emission in a quasi-optical gyrotron

    International Nuclear Information System (INIS)

    Alberti, S.; Pedrozzi, M.; Tran, M.Q.; Hogge, J.P.; Tran, T.M.; Muggli, P.; Joedicke, B.; Mathews, H.G.

    1990-04-01

    A quasi-optical gyrotron (QOG) designed for operation at the fundamental (Ω ce ≅100 GHz) exhibits simultaneous emission at Ω ce and 2Ω ce (second harmonic). For a beam current of 4 A, 20% of the total RF power is emitted at the second harmonic. The experimental measurements show that the excitation of the second harmonic is only possible when the fundamental is present. The frequency of the second harmonic is locked by the frequency of the fundamental. Experimental evidence shows that when the second harmonic is not excited, total efficiency is enhanced. (author) 6 refs., 5 figs., 1 tab

  3. SO2 EMISSION MEASUREMENT BY DOAS (DIFFERENTIAL OPTICAL ABSORPTION SPECTROSCOPY AND COSPEC (CORRELATION SPECTROSCOPY AT MERAPI VOLCANO (INDONESIA

    Directory of Open Access Journals (Sweden)

    Hanik Humaida

    2010-06-01

    Full Text Available The SO2 is one of the volcanic gases that can use as indicator of volcano activity. Commonly, SO2 emission is measured by COSPEC (Correlation Spectroscopy. This equipment has several disadvantages; such as heavy, big in size, difficulty in finding spare part, and expensive. DOAS (Differential Optical Absorption Spectroscopy is a new method for SO2 emission measurement that has advantages compares to the COSPEC. Recently, this method has been developed. The SO2 gas emission measurement of Gunung Merapi by DOAS has been carried out at Kaliadem, and also by COSPEC method as comparation. The differences of the measurement result of both methods are not significant. However, the differences of minimum and maximum result of DOAS method are smaller than that of the COSPEC. It has range between 51 ton/day and 87 ton/day for DOAS and 87 ton/day and 201 ton/day for COSPEC. The measurement of SO2 gas emission evaluated with the seismicity data especially the rockfall showed the presence of the positive correlation. It may cause the gas pressure in the subsurface influencing instability of 2006 eruption lava.   Keywords: SO2 gas, Merapi, DOAS, COSPEC

  4. Optical emission spectroscopy at the large RF driven negative ion test facility ELISE: Instrumental setup and first results

    International Nuclear Information System (INIS)

    Wünderlich, D.; Fantz, U.; Franzen, P.; Riedl, R.; Bonomo, F.

    2013-01-01

    One of the main topics to be investigated at the recently launched large (A source = 1.0 × 0.9 m 2 ) ITER relevant RF driven negative ion test facility ELISE (Extraction from a Large Ion Source Experiment) is the connection between the homogeneity of the plasma parameters close to the extraction system and the homogeneity of the extracted negative hydrogen ion beam. While several diagnostics techniques are available for measuring the beam homogeneity, the plasma parameters are determined by optical emission spectroscopy (OES) solely. First OES measurements close to the extraction system show that without magnetic filter field the vertical profile of the plasma emission is more or less symmetric, with maxima of the emission representing the projection of the plasma generation volumes, and a distinct minimum in between. The profile changes with the strength of the magnetic filter field but under all circumstances the plasma emission in ELISE is much more homogeneous compared to the smaller IPP prototype sources. Planned after this successful demonstration of the ELISE OES system is to combine OES with tomography in order to determine locally resolved values for the plasma parameters

  5. Plasma-related matrix effects in inductively coupled plasma--atomic emission spectrometry by group I and group II matrix-elements

    International Nuclear Information System (INIS)

    Chan, George C.-Y.; Chan, W.-T.

    2003-01-01

    The effects of Na, K, Ca and Ba matrices on the plasma excitation conditions in inductively coupled plasma-atomic emission spectrometry (ICP-AES) were studied. Normalized relative intensity was used to indicate the extent of the plasma-related matrix effects. The group I matrices have no effects on the plasma excitation conditions. In contrast, the group II matrices depress the normalized relative intensities of some spectral lines. Specifically, the Group II matrices have no effects on the normalized relative intensity of atomic lines of low upper energy level (soft lines), but reduce the normalized relative intensity of some ionic lines and atomic lines of high energy level (hard lines). The Group II matrices seem to shift the Saha balance of the analytes only; no shift in the Boltzmann balance was observed experimentally. Moreover, for some ionic lines with sum of ionization and excitation potentials close to the ionization potential of argon (15.75 eV), the matrix effect is smaller than other ionic lines of the same element. The reduced matrix effects may be attributed qualitatively to charge transfer excitation mechanism of these ionic lines. Charge transfer reaction renders ionic emission lines from the quasi-resonant levels similar in characteristics of atomic lines. The contribution of charge transfer relative to excitation by other non-specific excitation mechanisms (via Saha balance and Boltzmann balance) determines the degree of atomic behavior of a quasi-resonant level. A significant conclusion of this study is that plasma-related matrix effect depends strongly on the excitation mechanism of a spectral line. Since, in general, more than one excitation mechanism may contribute to the overall excitation of an emission line, the observed matrix effects reflect the sum of the effects due to individual excitation mechanisms. Excitation mechanisms, in addition to the often-used total excitation energy, should be considered in matrix effect studies

  6. Optical emission spectroscopy of metal vapor dominated laser-arc hybrid welding plasma

    International Nuclear Information System (INIS)

    Ribic, B.; DebRoy, T.; Burgardt, P.

    2011-01-01

    During laser-arc hybrid welding, plasma properties affect the welding process and the weld quality. However, hybrid welding plasmas have not been systematically studied. Here we examine electron temperatures, species densities, and electrical conductivity for laser, arc, and laser-arc hybrid welding using optical emission spectroscopy. The effects of arc currents and heat source separation distances were examined because these parameters significantly affect weld quality. Time-average plasma electron temperatures, electron and ion densities, electrical conductivity, and arc stability decrease with increasing heat source separation distance during hybrid welding. Heat source separation distance affects these properties more significantly than the arc current within the range of currents considered. Improved arc stability and higher electrical conductivity of the hybrid welding plasma result from increased heat flux, electron temperatures, electron density, and metal vapor concentrations relative to arc or laser welding.

  7. Monitoring of Optical Emission from High Temperature Plasma Based on Chromatic Modulation

    International Nuclear Information System (INIS)

    Dimitrios, Tomtsis

    2009-01-01

    An integrated experimental approach is presented for processing the optical emission produced from electric arc plasma. The method is based on chromatic modulation techniques to provide a holistic measurement of the persistence of particle decays within the environment of high power circuit breakers. Chromaticity changes in a number of chromatic parameters are related to changes in physical electric arc plasma environment (e.g. particle concentration). The results are in the form of chromatic maps which show how the overall electric arc plasma and its environment behave and respond. Such maps show the totality of information which can be accessed about the arcing event and the level of monitoring discrimination which is achievable with the chromatic methodology in a simple and easy to understand manner. The suggested method provides easier data analysis and high levels of data compression.

  8. {sup 134}Cs emission probabilities determination by gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, M.C.M. de, E-mail: candida@cnen.gov.br [Comissão Nacional de Energia Nuclear (DINOR/CNEN), Riode Janeiro, RJ (Brazil); Poledna, R.; Delgado, J.U.; Silva, R.L.; Araujo, M.T.; Silva, C.J. da [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) of Rio de Janeiro performed primary and secondary standardization of different radionuclides reaching satisfactory uncertainties. A solution of {sup 134}Cs radionuclide was purchased from commercial supplier to emission probabilities determination of some of its energies. {sup 134}Cs is a beta gamma emitter with 754 days of half-life. This radionuclide is used as standard in environmental, water and food control. It is also important to germanium detector calibration.The gamma emission probabilities (Pγ) were determined mainly for some energies of the {sup 134}Cs by efficiency curve method and the Pγ absolute uncertainties obtained were below 1% (k=1). (author)

  9. Determination of the mineral compositions of in six beans by microwave digestion with inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Yan, Q.; Yang, L.; Chen, S.; Liu, X.; Ma, X.

    2012-01-01

    In the study, microwave digestion procedure optimized was applied for digesting beans. Nineteen mineral element concentrations were determined by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The result indicated detection limits for the 19 elements were less than 0.0998, and relative standard deviations were 1.01% - 5.02% for all the elements, and recoveries were 90.89% - 104.55% by adding standard recovery experiment. The study showed the beans selected were abundant in mineral element contents in human nutrition, determination mineral element contents by ICP-AES with microwave digestion technology were a lot of merits of small environmental pollution, fast and accurate determination result, which could satisfy the examination request of bean samples. The results provided evidence that the six beans were a good source of K, P, Mg and Ca. This study is to give important reference value to people due to individual differences by adjusting the dietary to complement the different mineral elements. (author)

  10. EARLY OPTICAL OBSERVATIONS OF GAMMA-RAY BURSTS BY THE TAROT TELESCOPES: PERIOD 2001-2008

    International Nuclear Information System (INIS)

    Klotz, A.; Boer, M.; Atteia, J. L.; Gendre, B.

    2009-01-01

    The Telescopes a Action Rapide pour les Objets Transitoires telescopes are two robotic observatories designed to observe the prompt optical emission counterpart and the early afterglow of gamma-ray bursts (GRBs). We present data acquired between 2001 and 2008 and discuss the properties of the optical emission of GRBs, noting various interesting results. The optical emission observed during the prompt GRB phase is rarely very bright: we estimate that 5%-20% of GRBs exhibit a bright optical flash (R < 14) during the prompt gamma-ray emission, and that more than 50% of the GRBs have an optical emission fainter than R = 15.5 when the gamma-ray emission is active. We study the apparent optical brightness distribution of GRBs at 1000 s showing that our observations confirm the distribution derived by other groups. The combination of these results with those obtained by other rapid slewing telescopes allows us to better characterize the early optical emission of GRBs and to emphasize the importance of very early multiwavelength GRB studies for the understanding of the physics of the ejecta.

  11. A history of mass spectrometry in Australia

    Energy Technology Data Exchange (ETDEWEB)

    Downard, K.M.; de Laeter, J.R. [University of Sydney, Sydney, NSW (Australia)

    2005-09-01

    An interest in mass spectrometry in Australia can be traced back to the 1920s with an early correspondence with Francis Aston who first visited these shores a decade earlier. The region has a rich tradition in both the development of the field and its application, from early measurements of ionization and appearance potentials by Jim Morrison at the Council for Scientific and Industrial Research (CSIR) around 1950 to the design and construction of instrumentation including the first use of a triple quadrupole mass spectrometer for tandem mass spectrometry, the first suite of programs to simulate ion optics (SIMION), the development of early TOF/TOF instruments and orthogonal acceleration and the local design and construction of several generations of a sensitive high-resolution ion microprobe (SHRIMP) instrument. Mass spectrometry has been exploited in the study and characterization of the constituents of this nation's unique flora and fauna from Australian apples, honey, tea plant and eucalyptus oil, snake, spider, fish and frog venoms, coal, oil, sediments and shale, environmental studies of groundwater to geochronological dating of limestone and granite, other terrestrial and meteoritic rocks and coral from the Great Barrier Reef. This article traces the history of mass spectrometry in its many guises and applications in the island continent of Australia. It focuses on contributions of scientists who played a major role in the early establishment of mass spectrometry in Australia. In general, those who are presently active in the field, and whose histories are incomplete, have been mentioned at best only briefly despite their important contributions to the field.

  12. Regulation of Floral Terpenoid Emission and Biosynthesis in Sweet Basil (Ocimum basilicum).

    Science.gov (United States)

    Jiang, Yifan; Ye, Jiayan; Li, Shuai; Niinemets, Ülo

    2016-12-01

    Past studies have focused on the composition of essential oil of Ocimum basilicum leaves, but data on composition and regulation of its aerial emissions, especially floral volatile emissions are scarce. We studied the chemical profile, within-flower spatial distribution (sepals, petals, pistils with stamina and pedicels), diurnal emission kinetics and effects of exogenous methyl jasmonate (MeJA) application on the emission of floral volatiles by dynamic headspace collection and identification using gas chromatography-mass spectrometry (GC-MS) and proton transfer reaction mass spectrometry (PTR-MS). We observed more abundant floral emissions from flowers compared with leaves. Sepals were the main emitters of floral volatiles among the flower parts studied. The emissions of lipoxygenase compounds (LOX) and monoterpenoids, but not sesquiterpene emissions, displayed a diurnal variation driven by light. Response to exogenous MeJA treatment of flowers consisted of a rapid stress response and a longer-term acclimation response. The initial response was associated with enhanced emissions of fatty acid derivatives, monoterpenoids, and sesquiterpenoids without variation of the composition of individual compounds. The longer-term response was associated with enhanced monoterpenoid and sesquiterpenoid emissions with profound changes in the emission spectrum. According to correlated patterns of terpenoid emission changes upon stress, highlighted by a hierarchical cluster analysis, candidate terpenoid synthases responsible for observed diversity and complexity of released terpenoid blends were postulated. We conclude that flower volatile emissions differ quantitatively and qualitatively from leaf emissions, and overall contribute importantly to O. basilicum flavor, especially under stress conditions.

  13. single photon emission tomography and positron emission tomography - Part 1 (October 2012), Part 2 (October 2010)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2010-10-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) and the positron emission tomography (PET) imaging techniques. Part 1 Content: 1 - Introduction: anatomic, functional and molecular imaging; 2 - Radiotracers: chemical and physical constraints, gamma photon emitters, positon emitters, radioisotopes production, emitters type and imaging techniques; 3 - Gamma cameras; 4 - Quantification in emission tomography: attenuation, scattering, un-stationary spatial resolution; 5 - Synthesis and conclusion. Part 2 content: 1 - Positon emitters; 2 - Positons detection: Coincidence detection (electronic collimation, PET detectors with gamma cameras, dedicated PET detectors, spectrometry); PET detectors type; time-of-flight PET; 2D PET; 3D PET; 3 - Quantification in emission tomography: detected events, attenuation, scattering, fortuitous coincidences, standardisation; 4 - Common SPECT and PET problems: partial volume effect, movement, tomographic reconstruction, calibration, dead time; 5 - Synthesis and conclusion

  14. Methodology for determination of activity of radionuclides by gamma spectrometry

    International Nuclear Information System (INIS)

    Fragoso, Maria da Conceicao de Farias; Oliveira, Victor Rogerio S. de; Oliveira, Mercia L.; Lima, Fernando Roberto de Andrade

    2014-01-01

    Due to the growth in the number of procedures that make use of the positron emission tomography (PET), there is a need for standard solutions for the calibration of the systems used for the measurement of the PET radiopharmaceutical (activimeter) in radiopharmacies and in nuclear medicine services. Among the existing alternatives for the standardization of radioactive sources, the method known as gamma spectrometry is widely used for short-lived radionuclides. The purpose of this study was to implement the methodology for standardization of the 18 F solutions by gamma spectrometry at the Regional Center for Nuclear Sciences of the Northeast (CRCN-NE/CNEN-NE), Brazil. (author)

  15. A facile synthesis of graphene oxide–ZnS/ZnO nanocomposites and observations of thermal quenching of visible photoluminescence emission and nonlinear optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Kole, A.K.; Biswas, S. [Nanoscience Laboratory, Dept. of Physics, National Institute of Technology, Durgapur 713209, West Bengal (India); Tiwary, C.S. [Department of Materials Engineering, Indian Institute of Science, Bangalore (India); Kumbhakar, P., E-mail: pathik.kumbhakar@phy.nitdgp.ac.in [Nanoscience Laboratory, Dept. of Physics, National Institute of Technology, Durgapur 713209, West Bengal (India)

    2016-11-15

    Here we have reported a facile synthesis of graphene oxide–ZnS/ZnO nanocomposite and the temperature dependent photoluminescence (PL) emissions in the synthesized materials, which are scarcely been available in the literature. In the present work PL emission in GO and its composites with ZnS and ZnO semiconductor quantum dots (QDs) have been measured at variable temperatures in 283–353 K temperature region. From the measured results it has been found that quenching of PL emission has been taken place in the composite sample and it has been proposed that as the temperature is increased, the excited electrons in the localized states formed by the sp{sup 2} clusters in GO can migrate to the nearby sp{sup 3} defects states, thereby the intensity of PL emission is reduced. Nonlinear Optical (NLO) properties as well as the optical limiting (OL) properties has also been studied by using an indigenously developed Z-scan technique with a 10 ns laser pulse at 1064 nm laser radiation. Two photon absorptions (2PA) behavior have been found to be the dominant mechanism in the synthesized samples. A suitable energy level scheme has been proposed to explain the observed PL emission behavior as well as the 2PA mechanism. The present report will open up a lot of prospects for synthesizing GO-semiconductor nanocomposites with semiconductor materials as well as for potential applications in future luminescent devices.

  16. Polarization and emission geometry of the Crab pulsar

    International Nuclear Information System (INIS)

    Kaiyou Chen; Cheng Ho

    1993-01-01

    Optical emission of the Crab pulsar can best be understood as synchrotron radiation of relativistic particles from the outer magnetosphere of the neutron star. The outer gap model was developed specifically to address energy balance and double-pulsed emission (from optical to high-energy gamma-ray) of young pulsars like the Crab. In this paper, we present the polarization properties of the optical pulses calculated from the outer gap model. We found that the theoretical light curves exhibit the same qualitative behavior as observations

  17. Ion optics of a new time-of-flight mass spectrometer for quantitative surface analysis

    International Nuclear Information System (INIS)

    Veryovkin, Igor V.; Calaway, Wallis F.; Pellin, Michael J.

    2004-01-01

    A new time-of-flight instrument for quantitative surface analysis was developed and constructed at Argonne National Laboratory. It implements ion sputtering and laser desorption for probing analyzed samples and can operate in regimes of secondary neutral mass spectrometry with laser post-ionization and secondary ion mass spectrometry. The instrument incorporates two new ion optics developments: (1) 'push-pull' front end ion optics and (2) focusing and deflecting lens. Implementing these novel elements significantly enhance analytical capabilities of the instrument. Extensive three-dimensional computer simulations of the instrument were conducted in SIMION 3D (c) to perfect its ion optics. The operating principles of the new ion optical systems are described, and a scheme of the new instrument is outlined together with its operating modes

  18. Construction and use of an optical semi-automatic titrator employing the technique of reflectance photometry

    International Nuclear Information System (INIS)

    Hwang, Hoon

    2001-01-01

    An optical semi-automatic titrator was constructed employing the technique of the reflectance spectrometry and was tested for the determination of the end points of the acid-base, precipitation, and EDTA titrations. And since the current optical semi-automatic titrator built on the principle of the reflectance spectrometry could be successfully used even for the determination of the end of the end point in the precipitation titration where the solid particles are formed during the titration process, it was found to be feasible that a completely automated optical titrator would be designed and built based on the current findings

  19. Quantum optics with semiconductor nanostructures

    CERN Document Server

    Jahnke, Frank

    2012-01-01

    A guide to the theory, application and potential of semiconductor nanostructures in the exploration of quantum optics. It offers an overview of resonance fluorescence emission.$bAn understanding of the interaction between light and matter on a quantum level is of fundamental interest and has many applications in optical technologies. The quantum nature of the interaction has recently attracted great attention for applications of semiconductor nanostructures in quantum information processing. Quantum optics with semiconductor nanostructures is a key guide to the theory, experimental realisation, and future potential of semiconductor nanostructures in the exploration of quantum optics. Part one provides a comprehensive overview of single quantum dot systems, beginning with a look at resonance fluorescence emission. Quantum optics with single quantum dots in photonic crystal and micro cavities are explored in detail, before part two goes on to review nanolasers with quantum dot emitters. Light-matter interaction...

  20. Multi-mode optical fibers for connecting space-based spectrometers

    Science.gov (United States)

    Roberts, W. T.; Lindenmisth, C. A.; Bender, S.; Miller, E. A.; Motts, E.; Ott, M.; LaRocca, F.; Thomes, J.

    2017-11-01

    Laser spectral analysis systems are increasingly being considered for in situ analysis of the atomic and molecular composition of selected rock and soil samples on other planets [1][2][3]. Both Laser Induced Breakdown Spectroscopy (LIBS) and Raman spectroscopy are used to identify the constituents of soil and rock samples in situ. LIBS instruments use a high peak-power laser to ablate a minute area of the surface of a sample. The resulting plasma is observed with an optical head, which collects the emitted light for analysis by one or more spectrometers. By identifying the ion emission lines observed in the plasma, the constituent elements and their abundance can be deduced. In Raman spectroscopy, laser photons incident on the sample surface are scattered and experience a Raman shift, exchanging small amounts of energy with the molecules scattering the light. By observing the spectrum of the scattered light, it is possible to determine the molecular composition of the sample. For both types of instruments, there are advantages to physically separating the light collecting optics from the spectroscopy optics. The light collection system will often have articulating or rotating elements to facilitate the interrogation of multiple samples with minimum expenditure of energy and motion. As such, the optical head is often placed on a boom or an appendage allowing it to be pointed in different directions or easily positioned in different locations. By contrast, the spectrometry portion of the instrument is often well-served by placing it in a more static location. The detectors often operate more consistently in a thermally-controlled environment. Placing them deep within the spacecraft structure also provides some shielding from ionizing radiation, extending the instrument's useful life. Finally, the spectrometry portion of the instrument often contains significant mass, such that keeping it off of the moving portion of the platform, allowing that portion to be

  1. Initial Gamma Spectrometry Examination of the AGR-3/4 Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Harp, Jason M.; Demkowicz, Paul A.; Stempien, John D.

    2016-11-01

    The initial results from gamma spectrometry examination of the different components from the combined third and fourth US Advanced Gas Reactor Fuel Development TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail particles surrounded by two graphitic diffusion rings (inner and outer) and a graphite sink were irradiated in the Idaho National Laboratory’s Advanced Test Reactor. Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. Additionally, inner and outer rings were also examined by gamma spectrometry both to evaluate the fission product inventory and the distribution of gamma-emitting fission products within the rings using gamma emission computed tomography. The cesium inventory of the scanned rings compares acceptably well with the expected inventory from fission product transport modeling. The inventory of the graphite fission product sinks is also being evaluated by gamma spectrometry.

  2. Critical comparison of performances of inductively coupled plasma atomic emission spectrometry and neutron activation analysis for the determination of elements in human lungs

    International Nuclear Information System (INIS)

    Alimonti, A.; Coni, E.; Caroli, S.; Sabbioni, E.; Nicolaou, G.E.; Pietra, R.

    1989-01-01

    A study was carried out to assess the performance of inductively coupled plasma atomic emission spectrometry (ICP-AES) and neutron activation analysis (NAA) techniques for determining reference values for Al, Cd, Cr, Cu, Mg, Mn, V and Zn in human lungs of urban non-smoking subjects. Experimental data were subjected to the usual basic statistical tests to evaluate the respective merits of the two basically different analytical techniques. Both approaches, if used under carefully optimised experimental conditions, can yield reliable results affected only minimally by systematic and random errors. On the other hand, on a more routine basis, particular attention should be paid to elements such as Al, Cd and V which may pose some problems with both techniques. (author)

  3. Inductively coupled plasma-mass spectrometry: an initial assessment of the VG isotopes Plasmaquad

    International Nuclear Information System (INIS)

    Brown, R.M.; Pickford, C.J.

    1985-04-01

    The Chemical Analysis Group has been approached by a British Scientific instrument maker regarding the possibility of the group participating in a Department of Trade and Industry sponsored scheme whereby we would have a 12 month period to assess the advantages and disadvantages of a new analytical technique, Inductively Coupled Plasma-Mass Spectrometry. This report details our initial assessment of the instrument, carried out in order to decide whether to participate in the scheme. We have attempted to discover whether the instrument meets the claims made of it in advertising literature, and have attempted to compare the technique with another, proven technique, Inductively Coupled Plasma - Optical Emission Spectroscopy. The Plasmaquad offers excellent sensitivity for almost all of the elements of the periodic table, giving a distinct improvement over the Chemical Analysis Group's present capabilities for many elements. The isotope ratio measuring ability is important, as the Group has no such capability at the moment and a demand for this type of measurement is foreseen. Our conclusions, while inevitably somewhat subjective, form the basis for recommending Harwell to participate in the scheme. (author)

  4. Reduction of interferences in graphite furnace atomic absorption spectrometry by multiple linear regression modelling

    Science.gov (United States)

    Grotti, Marco; Abelmoschi, Maria Luisa; Soggia, Francesco; Tiberiade, Christian; Frache, Roberto

    2000-12-01

    The multivariate effects of Na, K, Mg and Ca as nitrates on the electrothermal atomisation of manganese, cadmium and iron were studied by multiple linear regression modelling. Since the models proved to efficiently predict the effects of the considered matrix elements in a wide range of concentrations, they were applied to correct the interferences occurring in the determination of trace elements in seawater after pre-concentration of the analytes. In order to obtain a statistically significant number of samples, a large volume of the certified seawater reference materials CASS-3 and NASS-3 was treated with Chelex-100 resin; then, the chelating resin was separated from the solution, divided into several sub-samples, each of them was eluted with nitric acid and analysed by electrothermal atomic absorption spectrometry (for trace element determinations) and inductively coupled plasma optical emission spectrometry (for matrix element determinations). To minimise any other systematic error besides that due to matrix effects, accuracy of the pre-concentration step and contamination levels of the procedure were checked by inductively coupled plasma mass spectrometric measurements. Analytical results obtained by applying the multiple linear regression models were compared with those obtained with other calibration methods, such as external calibration using acid-based standards, external calibration using matrix-matched standards and the analyte addition technique. Empirical models proved to efficiently reduce interferences occurring in the analysis of real samples, allowing an improvement of accuracy better than for other calibration methods.

  5. Optical Observations of X-ray Bright, Optically Normal Galaxies

    Science.gov (United States)

    Sadun, Alberto C.; Aryan, N. S.; Ghosh, K. K.

    2007-05-01

    X-ray bright, optically normal galaxies (XBONGs) are galaxies that seem to have normal spectra and morphology, but are relatively bright x-ray sources. The large ratio of the x-ray to optical emission suggests that some activity, similar to that of active galactic nuclei (AGN), is occurring. Since the galaxies do not show any obvious sign of nuclear activity in their optical spectra, one possible explanation is that these galaxies do not have an optically thick accretion disk at small radii, as previously assumed. Previous data for NGC 7626 classifies it as an XBONG, and so we are studying optical features of this galaxy in order to determine better its features. After confirming an x-ray jet, we are now comparing this to optical features that we have found, including warped dust lanes and a possible optical jet.

  6. A COMPREHENSIVE STUDY OF GAMMA-RAY BURST OPTICAL EMISSION. II. AFTERGLOW ONSET AND LATE RE-BRIGHTENING COMPONENTS

    Energy Technology Data Exchange (ETDEWEB)

    Liang Enwei; Li Liang; Liang Yunfeng; Tang Qingwen; Chen Jiemin; Lu Ruijing; Lue Lianzhong [Department of Physics and GXU-NAOC Center for Astrophysics and Space Sciences, Guangxi University, Nanning 530004 (China); Gao He; Zhang, Bing; Lue Houjun [Department of Physics and Astronomy, University of Nevada, Las Vegas, NV 89154 (United States); Wu Xuefeng [Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008 (China); Yi Shuangxi; Dai Zigao [School of Astronomy and Space Science, Nanjing University, Nanjing, Jiangsu 210093 (China); Zhang Jin; Wei Jianyan, E-mail: lew@gxu.edu.cn, E-mail: zhang@physics.unlv.edu [National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China)

    2013-09-01

    We continue our systematic statistical study of various components of gamma-ray burst (GRB) optical light curves. We decompose the early onset bump and the late re-brightening bump with empirical fits and analyze their statistical properties. Among the 146 GRBs that have well-sampled optical light curves, the onset and re-brightening bumps are observed in 38 and 26 GRBs, respectively. It is found that the typical rising and decaying slopes for both the onset and re-brightening bumps are {approx}1.5 and {approx} - 1.15, respectively. No early onset bumps in the X-ray band are detected to be associated with the optical onset bumps, while an X-ray re-brightening bump is detected for half of the re-brightening optical bumps. The peak luminosity is anti-correlated with the peak time L{sub p}{proportional_to}t{sub p}{sup -1.81{+-}0.32} for the onset bumps and L{sub p}{proportional_to}t{sub p}{sup -0.83{+-}0.17} for the re-brightening bumps. Both L{sub p} and the isotropic energy release of the onset bumps are correlated with E{sub {gamma},iso}, whereas no similar correlation is found for the re-brightening bumps. These results suggest that the afterglow onset bumps are likely due to the deceleration of the GRB fireballs. Taking the onset bumps as probes for the properties of the fireballs and their ambient medium, we find that the typical power-law index of the relativistic electrons is 2.5 and the medium density profile behaves as n{proportional_to}r {sup -1} within the framework of the synchrotron external shock models. With the medium density profile obtained from our analysis, we also confirm the correlation between the initial Lorentz factor ({Gamma}{sub 0}) and E{sub iso,{gamma}} in our previous work. The jet component that produces the re-brightening bump seems to be on-axis and independent of the prompt emission jet component. Its typical kinetic energy budget would be about one order of magnitude larger than the prompt emission component, but with a lower {Gamma

  7. Emission lines of [K V] in the optical spectra of gaseous nebulae.

    Science.gov (United States)

    Keenan, Francis P; Aller, Lawrence H; Espey, Brian R; Exter, Katrina M; Hyung, Siek; Keenan, Michael T C; Pollacco, Don L; Ryans, Robert S I

    2002-04-02

    Recent R-matrix calculations of electron impact excitation rates in K v are used to derive the nebular emission line ratio R = I(4122.6 A)/I(4163.3 A) as a function of electron density (N(e)). This ratio is found to be very sensitive to changes in N(e) over the density range 10(3) to 10(6) cm(-3), but does not vary significantly with electron temperature, and hence in principle should provide an excellent optical N(e) diagnostic for the high-excitation zones of nebulae. The observed value of R for the planetary nebula NGC 7027, measured from a spectrum obtained with the Hamilton Echelle spectrograph on the 3-m Shane Telescope, implies a density in excellent agreement with that derived from [Ne iv], formed in the same region of the nebula as [K v]. This observation provides observational support for the accuracy of the theoretical [K v] line ratios, and hence the atomic data on which they are based. However, the analysis of a high-resolution spectrum of the symbiotic star RR Telescopii, obtained with the University College London Echelle Spectrograph on the 3.9-m Anglo-Australian Telescope, reveals that the [K v] 4122.6 A line in this object is badly blended with Fe ii 4122.6 A. Hence, the [K v] diagnostic may not be used for astrophysical sources that show a strong Fe ii emission line spectrum.

  8. Optical Absorption and Emission Mechanisms of Single Defects in Hexagonal Boron Nitride

    Science.gov (United States)

    Jungwirth, Nicholas R.; Fuchs, Gregory D.

    2017-08-01

    We investigate the polarization selection rules of sharp zero-phonon lines (ZPLs) from isolated defects in hexagonal boron nitride (HBN) and compare our findings with the predictions of a Huang-Rhys model involving two electronic states. Our survey, which spans the spectral range ˜550 - 740 nm , reveals that, in disagreement with a two-level model, the absorption and emission dipoles are often misaligned. We relate the dipole misalignment angle (Δ θ ) of a ZPL to its energy shift from the excitation energy (Δ E ) and find that Δ θ ≈0 ° when Δ E corresponds to an allowed HBN phonon frequency and that 0 ° ≤Δ θ ≤90 ° when Δ E exceeds the maximum allowed HBN phonon frequency. Consequently, a two-level Huang-Rhys model succeeds at describing excitations mediated by the creation of one optical phonon but fails at describing excitations that require the creation of multiple phonons. We propose that direct excitations requiring the creation of multiple phonons are inefficient due to the low Huang-Rhys factors in HBN and that these ZPLs are instead excited indirectly via an intermediate electronic state. This hypothesis is corroborated by polarization measurements of an individual ZPL excited with two distinct wavelengths that indicate a single ZPL may be excited by multiple mechanisms. These findings provide new insight on the nature of the optical cycle of novel defect-based single-photon sources in HBN.

  9. Determination of cadmium(II), cobalt(II), nickel(II), lead(II), zinc(II), and copper(II) in water samples using dual-cloud point extraction and inductively coupled plasma emission spectrometry.

    Science.gov (United States)

    Zhao, Lingling; Zhong, Shuxian; Fang, Keming; Qian, Zhaosheng; Chen, Jianrong

    2012-11-15

    A dual-cloud point extraction (d-CPE) procedure has been developed for simultaneous pre-concentration and separation of heavy metal ions (Cd2+, Co2+, Ni2+, Pb2+, Zn2+, and Cu2+ ion) in water samples by inductively coupled plasma optical emission spectrometry (ICP-OES). The procedure is based on forming complexes of metal ion with 8-hydroxyquinoline (8-HQ) into the as-formed Triton X-114 surfactant rich phase. Instead of direct injection or analysis, the surfactant rich phase containing the complexes was treated by nitric acid, and the detected ions were back extracted again into aqueous phase at the second cloud point extraction stage, and finally determined by ICP-OES. Under the optimum conditions (pH=7.0, Triton X-114=0.05% (w/v), 8-HQ=2.0×10(-4) mol L(-1), HNO3=0.8 mol L(-1)), the detection limits for Cd2+, Co2+, Ni2+, Pb2+, Zn2+, and Cu2+ ions were 0.01, 0.04, 0.01, 0.34, 0.05, and 0.04 μg L(-1), respectively. Relative standard deviation (RSD) values for 10 replicates at 100 μg L(-1) were lower than 6.0%. The proposed method could be successfully applied to the determination of Cd2+, Co2+, Ni2+, Pb2+, Zn2+, and Cu2+ ion in water samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Measurement of non-enteric emission fluxes of volatile fatty acids from a California dairy by solid phase micro-extraction with gas chromatography/mass spectrometry

    Science.gov (United States)

    Alanis, Phillip; Sorenson, Mark; Beene, Matt; Krauter, Charles; Shamp, Brian; Hasson, Alam S.

    Dairies are a major source of volatile organic compounds (VOCs) in California's San Joaquin Valley; a region that experiences high ozone levels during summer. Short-chain carboxylic acids, or volatile fatty acids (VFAs), are believed to make up a large fraction of VOC emissions from these facilities, although there are few studies to substantiate this. In this work, a method using a flux chamber coupled to solid phase micro-extraction (SPME) fibers followed by analysis using gas chromatography/mass spectrometry was developed to quantify emissions of six VFAs (acetic acid, propanoic acid, butanoic acid, pentanoic acid, hexanoic acid and 3-methyl butanoic acid) from non-enteric sources. The technique was then used to quantify VFA fluxes from a small dairy located on the campus of California State University Fresno. Both animal feed and animal waste are found to be major sources of VFAs, with acetic acid contributing 70-90% of emissions from the sources tested. Measured total acid fluxes during spring (with an average temperature of 20 °C) were 1.84 ± 0.01, 1.06 ± 0.08, (1.3 ± 0.5) × 10 -2, (1.7 ± 0.2) × 10 -2 and (1.2 ± 0.5) × 10 -2 g m -2 h -1 from silage, total mixed rations, flushing lane, open lot and lagoon sources, respectively. VFA emissions from the sources tested total 390 ± 80 g h -1. The data indicate high fluxes of VFAs from dairy facilities, but differences in the design and operation of dairies in the San Joaquin Valley as well as seasonal variations mean that additional measurements must be made to accurately determine emissions inventories for the region.

  11. Development of ICP-MS and ICP-OES methods for determination of gadolinium in samples related to hospital waste water treatment

    Czech Academy of Sciences Publication Activity Database

    Bendakovská, L.; Krejčovská, A.; Černohorský, T.; Zelenková, Jana

    2016-01-01

    Roč. 70, č. 9 (2016), s. 1155-1165 ISSN 0366-6352 Institutional support: RVO:67985874 Keywords : gadolinium * rare-earth elements * bioaccumulation * gadolinium anomaly * inductively coupled plasma mass spectrometry (ICP-MS) * inductively coupled plasma optical emission spectrometry (ICP-OES) Subject RIV: BK - Fluid Dynamics Impact factor: 1.258, year: 2016

  12. Preconcentration of uranium in water samples using dispersive ...

    African Journals Online (AJOL)

    Preconcentration of uranium in water samples using dispersive liquid-liquid micro- extraction coupled with solid-phase extraction and determination with inductively coupled plasma-optical emission spectrometry.

  13. Regulation of Floral Terpenoid Emission and Biosynthesis in Sweet Basil (Ocimum basilicum)

    Science.gov (United States)

    Jiang, Yifan; Ye, Jiayan; Li, Shuai; Niinemets, Ülo

    2018-01-01

    Past studies have focused on the composition of essential oil of Ocimum basilicum leaves, but data on composition and regulation of its aerial emissions, especially floral volatile emissions are scarce. We studied the chemical profile, within-flower spatial distribution (sepals, petals, pistils with stamina and pedicels), diurnal emission kinetics and effects of exogenous methyl jasmonate (MeJA) application on the emission of floral volatiles by dynamic headspace collection and identification using gas chromatography-mass spectrometry (GC-MS) and proton transfer reaction mass spectrometry (PTR-MS). We observed more abundant floral emissions from flowers compared with leaves. Sepals were the main emitters of floral volatiles among the flower parts studied. The emissions of lipoxygenase compounds (LOX) and monoterpenoids, but not sesquiterpene emissions, displayed a diurnal variation driven by light. Response to exogenous MeJA treatment of flowers consisted of a rapid stress response and a longer-term acclimation response. The initial response was associated with enhanced emissions of fatty acid derivatives, monoterpenoids, and sesquiterpenoids without variation of the composition of individual compounds. The longer-term response was associated with enhanced monoterpenoid and sesquiterpenoid emissions with profound changes in the emission spectrum. According to correlated patterns of terpenoid emission changes upon stress, highlighted by a hierarchical cluster analysis, candidate terpenoid synthases responsible for observed diversity and complexity of released terpenoid blends were postulated. We conclude that flower volatile emissions differ quantitatively and qualitatively from leaf emissions, and overall contribute importantly to O. basilicum flavor, especially under stress conditions. PMID:29367803

  14. SHOK—The First Russian Wide-Field Optical Camera in Space

    Science.gov (United States)

    Lipunov, V. M.; Gorbovskoy, E. S.; Kornilov, V. G.; Panasyuk, M. I.; Amelushkin, A. M.; Petrov, V. L.; Yashin, I. V.; Svertilov, S. I.; Vedenkin, N. N.

    2018-02-01

    Onboard the spacecraft Lomonosov is established two fast, fixed, very wide-field cameras SHOK. The main goal of this experiment is the observation of GRB optical emission before, synchronously, and after the gamma-ray emission. The field of view of each of the cameras is placed in the gamma-ray burst detection area of other devices located onboard the "Lomonosov" spacecraft. SHOK provides measurements of optical emissions with a magnitude limit of ˜ 9-10m on a single frame with an exposure of 0.2 seconds. The device is designed for continuous sky monitoring at optical wavelengths in the very wide field of view (1000 square degrees each camera), detection and localization of fast time-varying (transient) optical sources on the celestial sphere, including provisional and synchronous time recording of optical emissions from the gamma-ray burst error boxes, detected by the BDRG device and implemented by a control signal (alert trigger) from the BDRG. The Lomonosov spacecraft has two identical devices, SHOK1 and SHOK2. The core of each SHOK device is a fast-speed 11-Megapixel CCD. Each of the SHOK devices represents a monoblock, consisting of a node observations of optical emission, the electronics node, elements of the mechanical construction, and the body.

  15. Investigation of local thermodynamic equilibrium of laser induced Al2O3–TiC plasma in argon by spatially resolved optical emission spectroscopy

    Directory of Open Access Journals (Sweden)

    K. Alnama

    2016-06-01

    Full Text Available Plasma plume of Al2O3–TiC is generated by third harmonic Q-switched Nd:YAG nanosecond laser. It is characterized using Optical Emission Spectroscopy (OES at different argon background gas pressures 10, 102, 103, 104 and 105 Pa. Spatial evolution of excitation and ionic temperatures is deduced from spectral data analysis. Temporal evolution of Ti I emission originated from different energy states is probed. The correlation between the temporal behavior and the spatial temperature evolution are investigated under LTE condition for the possibility to use the temporal profile of Ti I emission as an indicator for LTE validity in the plasma.

  16. Isotopic Tracing of Fuel Components in Particulate Emissions from Diesel Engines using Accelerator Mass Spectrometry (AMS)

    International Nuclear Information System (INIS)

    Buchholz, B A; Mueller, C J; Garbak, J.

    2001-01-01

    Accelerator mass spectrometry (AMS) is an isotope-ratio measurement technique developed in the late 1970s for tracing long-lived radioisotopes (e.g., 14 C half life = 5760 y). The technique counts individual nuclei rather than waiting for their radioactive decay, allowing measurement of more than 100 low-level 14 C samples per day (Vogel et al, 1995). The LLNL AMS system is shown in Fig.1. The contemporary quantity of 14 C in living things ( 14 C/C = 1.2 x 10 -12 or 110 fmol 14 C/ g C) is highly elevated compared to the quantity of 14 C in petroleum-derived products. This isotopic elevation is sufficient to trace the fate of bio-derived fuel components in the emissions of an engine without the use of radioactive materials. If synthesis of a fuel component from biologically-derived source material is not feasible, another approach is to purchase 14 C-labeled material (e.g., dibutyl maleate (DBM)) and dilute it with petroleum-derived material to yield a contemporary level of 14 C. In each case, the virtual absence of 14 C in petroleum based fuels gives a very low 14 C background that makes this approach to tracing fuel components practical. Regulatory pressure to significantly reduce the particulate emissions from diesel engines is driving research into understanding mechanisms of soot formation. If mechanisms are understood, then combustion modeling can be used to evaluate possible changes in fuel formulation and suggest possible fuel components that can improve combustion and reduce PM emissions. The combustion paradigm assumes that large molecules break down into small components and then build up again during soot formation. AMS allows us to label specific fuel components, including oxygenates, trace the carbon atoms, and test this combustion modeling paradigm. Volatile and non-volatile organic fractions (VOF, NVOF) in the PM can be further separated. The VOF of the PM can be oxidized with catalysts in the exhaust stream to further decrease PM. The effectiveness

  17. Two Fiber Optical Fiber Thermometry

    Science.gov (United States)

    Jones, Mathew R.; Farmer, Jeffery T.; Breeding, Shawn P.

    2000-01-01

    An optical fiber thermometer consists of an optical fiber whose sensing tip is given a metallic coating. The sensing tip of the fiber is essentially an isothermal cavity, so the emission from this cavity will be approximately equal to the emission from a blackbody. Temperature readings are obtained by measuring the spectral radiative heat flux at the end of the fiber at two wavelengths. The ratio of these measurements and Planck's Law are used to infer the temperature at the sensing tip. Optical fiber thermometers have high accuracy, excellent long-term stability and are immune to electromagnetic interference. In addition, they can be operated for extended periods without requiring re-calibration. For these reasons. it is desirable to use optical fiber thermometers in environments such as the International Space Station. However, it has recently been shown that temperature readings are corrupted by emission from the fiber when extended portions of the probe are exposed to elevated temperatures. This paper will describe several ways in which the reading from a second fiber can be used to correct the corrupted temperature measurements. The accuracy and sensitivity to measurement uncertainty will be presented for each method.

  18. Spectrometry and dosimetric evaluation of the gamma-ray emissions of 241Am

    International Nuclear Information System (INIS)

    Bradley, D.A.; Chong, C.S.

    1991-01-01

    New, detailed measurements have been made of the photon spectrum of the radionuclide 241 Am. Observations, recorded for a 95% confidence level over local background, provide affirmation of a number of lines previously considered to be of equivocal existence. A number of hitherto unreported emissions are similarly observed. Peak areas, expressed as a percentage of that for the 59.54 keV emission, have been ascribed to all lines of the detailed spectrum. This leads to an estimated increase in the value of exposure calculated from the measured fluence spectrum, relative to that from the 59.54 keV line, of (3.1 ± 0.8)%, taking into account all emissions beyond the predominating 59.54 keV gamma-ray emission. (author)

  19. Intraband dynamics and terahertz emission in biased semiconductor superlattices coupled to double far-infrared pulses

    International Nuclear Information System (INIS)

    Min, Li; Xian-Wu, Mi

    2009-01-01

    This paper studies both the intraband polarization and terahertz emission of a semiconductor superlattice in combined dc and ac electric fields by using the superposition of two identical time delayed and phase shifted optical pulses. By adjusting the delay between these two optical pulses, our results show that the intraband polarization is sensitive to the time delay. The peak values appear again for the terahertz emission intensity due to the superposition of two optical pulses. The emission lines of terahertz blueshift and redshift in different ac electric fields and dynamic localization appears. The emission lines of THz only appear to blueshift when the biased superlattice is driven by a single optical pulse. Due to excitonic dynamic localization, the terahertz emission intensity decays with time in different dc and ac electric fields. These are features of this superlattice which distinguish it from a superlattice generated by a single optical pulse to drive it. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  20. Tuning Ag29 nanocluster light emission from red to blue with one and two-photon excitation.

    Science.gov (United States)

    Russier-Antoine, Isabelle; Bertorelle, Franck; Hamouda, Ramzi; Rayane, Driss; Dugourd, Philippe; Sanader, Željka; Bonačić-Koutecký, Vlasta; Brevet, Pierre-François; Antoine, Rodolphe

    2016-02-07

    We demonstrate that the tuning of the light emission from red to blue in dihydrolipoic acid (DHLA) capped Ag29 nanoclusters can be trigged with one and two photon excitations. The cluster stoichiometry was determined with mass spectrometry and found to be Ag29(DHLA)12. In a detailed optical investigation, we show that these silver nanoclusters exhibit a strong red photoluminescence visible to the naked eye and characterized by a quantum yield of nearly ∼2% upon one-photon excitation. In the nonlinear optical (NLO) study of the properties of the clusters, the two-photon excited fluorescence spectra were recorded and their first hyperpolarizability obtained. The two-photon absorption cross-section at ∼800 nm for Ag29(DHLA)12 is higher than 10(4) GM and the hyperpolarizability is 106 × 10(-30) esu at the same excitation wavelength. The two-photon excited fluorescence spectrum appears strongly blue-shifted as compared to the one-photon excited spectrum, displaying a broad band between 400 and 700 nm. The density functional theory (DFT) provides insight into the structural and electronic properties of Ag29(DHLA)12 as well as into interplay between metallic subunit or core and ligands which is responsible for unique optical properties.