Sample records for ophthalmic viscosurgical device

  1. Effect of incisional friction and ophthalmic viscosurgical devices on the heat generation of ultrasound during cataract surgery.

    Science.gov (United States)

    Floyd, Michael; Valentine, Jeremy; Coombs, Jamie; Olson, Randall J

    2006-07-01

    To determine the thermal features of the Legacy (Alcon) and Sovereign (Advanced Medical Optics) phacoemulsification machines in a cadaver eye and with 7 ophthalmic viscosurgical devices (OVDs). In situ and in vitro study. Temperature without occlusion was recorded at the sleeve placed in the wound of a cadaver eye, and temperature over baseline was determined after 60 seconds. The result was then compared with the results in a previous study that used balanced salt solution (BSS) in artificial chambers. In the second portion of the experiment, with irrigation and aspiration lines occluded, temperature was recorded at the sleeve placed in an artificial chamber filled with sodium hyaluronate 2.3% (Healon5), sodium hyaluronate 1.4% (Healon GV), sodium hyaluronate 1.0% (Healon), sodium hyaluronate 1.6% (Amvisc Plus), sodium hyaluronate 1.0% (Provisc), sodium hyaluronate 3.0%-chondroitin sulfate 4.0% (Viscoat), or hyaluronate 3.0% (Vitrax). Temperature over baseline was also determined after 60 seconds. These results were compared with each set of OVD data and with the results in the prior BSS study. In the eye-bank model, the Legacy machine had a 62% temperature increase from incisional friction and the Sovereign machine had a decrease of 8.6% over results in an artificial anterior chamber. The OVD temperature increases were greater for the Sovereign (Pgeneration in the Legacy, a stroke-length driven instrument, more than in the Sovereign, a power-driven instrument. Ophthalmic viscosurgical devices are not only a concern due to outflow occlusion but can also add up to 6 times the heat in comparison with BSS. The need to aspirate the OVD before using ultrasound is thus verified.

  2. Safety, efficacy, and intraoperative characteristics of DisCoVisc and Healon ophthalmic viscosurgical devices for cataract surgery

    Directory of Open Access Journals (Sweden)

    Modi SS

    2011-09-01

    Full Text Available Satish S Modi1, James A Davison2, Tom Walters3 1Seeta Eye Centers, Poughkeepsie, NY, USA; 2Wolfe Clinic, Marshalltown, IA, USA; 3Texas Eye Care, Austin, TX, USA Purpose: To evaluate the safety and efficacy of DisCoVisc ophthalmic viscosurgical device (OVD, Alcon Laboratories, Inc with respect to a comparator, Healon OVD (Advanced Medical Optics, Inc. Patients and methods: In this prospective study, patients with cataracts were randomized to an OVD, and then received phacoemulsification and injection of an intraocular lens. After each surgery, unmasked investigators completed subjective questionnaires about OVD characteristics during each stage of the procedure. Masked technicians evaluated objective safety parameters of intraocular pressure (IOP and endothelial cell density, with 90 days of follow-up. Results: The DisCoVisc OVD group (128 eyes and the Healon OVD group (121 eyes had statistically similar outcomes for IOP and for endothelial cell loss. Subjectively assessed viscosity was statistically different (P < 0.0001, with Healon OVD most often rated “cohesive” and DisCoVisc OVD most often rated “both dispersive and cohesive”. Workspace maintenance differed between groups (P < 0.0001, with workspace most frequently rated “full chamber maintained” when using DisCoVisc OVD and most frequently rated “workspace maintained” when using Healon OVD. “Flat” or “shallow” workspace ratings occurred only in the Healon OVD group. Conclusion: DisCoVisc OVD had both cohesive and dispersive properties, and was safe and effective for every stage of cataract surgery. Keywords: cataract, endothelial cell density, viscoelastic, phacoemulsification

  3. Fluid temperature at the corneal endothelium during phacoemulsification: comparison of an ophthalmic viscosurgical device and balanced salt solution using the finite element method.

    Science.gov (United States)

    Reepolmaha, Somporn; Limtrakarn, Wiroj; Uthaisang-Tanechpongtamb, Wanlaya; Dechaumphai, Pramote

    2010-01-01

    The purpose of this study was to estimate and compare the temperatures of two different anterior chamber solutions at the corneal endothelial level during phacoemulsification. An ophthalmic viscosurgical device (OVD) and balanced salt solution (BSS) were compared using the finite element method (FEM). The thermal properties of an OVD (IAL-F) and BSS were studied in an experimental setting. A computer-aided design model of ocular anatomy was created in two dimensions. The phaco needle was considered to be the only source of heat generation. Then, the FEM was used to demonstrate the transient temperature distribution in the two ocular models at 10, 20, 30, 40, 50 and 60 s. In these models, the anterior chamber was filled with IAL-F (IAL-F model) or BSS (BSS model). The heat generation rate of the phaco needle was 0.0004 cal/s/mm(2). The maximum corneal endothelial temperatures for the two models at 60 s were 52.67 and 41.57 degrees C, respectively. The experimental IAL-F model showed fewer changes in temperature for any given time and location. At larger distances from the heat source, less temperature variation was detected. Phacoemulsification is a potential heat-generating procedure performed between the delicate anterior chamber structures. During this procedure, IAL-F protects the endothelium against heat better than BSS. Copyright 2009 S. Karger AG, Basel.

  4. Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model insertion in the immediate postoperative period

    Directory of Open Access Journals (Sweden)

    Ganesh S

    2016-01-01

    Full Text Available Sri Ganesh, Sheetal BrarDepartment of Phaco and Refractive Surgeries, Nethradhama Superspeciality Eye Hospital, Bangalore, IndiaPurpose: To compare the effect of two ocular viscosurgical devices (OVDs on intraocular pressure (IOP and surgical time in immediate postoperative period after bilateral implantable collamer lens (using the V4c model implantation.Methods: A total of 20 eligible patients were randomized to receive 2% hydroxypropylmethylcellulose (HPMC in one eye and 1% hyaluronic acid in fellow eye. Time taken for complete removal of OVD and total surgical time were recorded. At the end of surgery, IOP was adjusted between 15 and 20 mmHg in both the eyes.Results: Mean time for complete OVD evacuation and total surgical time were significantly higher in the HPMC group (P=0.00. Four eyes in the HPMC group had IOP spike, requiring treatment. IOP values with noncontact tonometry at 1, 2, 4, 24, and 48 hours were not statistically significant (P>0.05 for both the groups.Conclusion: The study concluded that 1% hyaluronic acid significantly reduces total surgical time, and incidence of acute spikes may be lower compared to 2% HPMC when used for implantable collamer lens (V4c model.Keywords: OVD, hyaluronic acid, ICL, V4c, IOP spikes

  5. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-11-15

    ... amendments), as ``preamendments devices.'' FDA classifies these devices after the Agency takes the following.... FDA-2012-N-1238] Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug AGENCY: Food... scleral plugs in order to provide a reasonable assurance of safety and effectiveness of the device. The...

  6. 21 CFR 886.4790 - Ophthalmic sponge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic sponge. 886.4790 Section 886.4790 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4790 Ophthalmic sponge. (a) Identification. An ophthalmic sponge is a device that is an absorbant sponge, pad, or spear made of folded gauze, cotton...

  7. 21 CFR 886.4390 - Ophthalmic laser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic laser. 886.4390 Section 886.4390 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4390 Ophthalmic laser. (a) Identification. An ophthalmic laser is an AC-powered device intended to coagulate or cut tissue of the eye, orbit, or surrounding skin...

  8. 21 CFR 886.1420 - Ophthalmic lens gauge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic lens gauge. 886.1420 Section 886.1420...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1420 Ophthalmic lens gauge. (a) Identification. An ophthalmic lens gauge is a calibrated device intended to manually measure the curvature of a...

  9. 21 CFR 886.4230 - Ophthalmic knife test drum.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic knife test drum. 886.4230 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4230 Ophthalmic knife test drum. (a) Identification. An ophthalmic knife test drum is a device intended to test the keenness of ophthalmic surgical...

  10. 21 CFR 886.5800 - Ophthalmic bar reader.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar reader. 886.5800 Section 886.5800...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5800 Ophthalmic bar reader. (a) Identification. An ophthalmic bar reader is a device that consists of a magnifying lens intended for use by a...

  11. 21 CFR 886.1650 - Ophthalmic bar prism.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar prism. 886.1650 Section 886.1650...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1650 Ophthalmic bar prism. (a) Identification. An ophthalmic bar prism is a device that is a bar composed of fused prisms of gradually increasing...

  12. 21 CFR 886.4750 - Ophthalmic eye shield.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4750 Ophthalmic eye shield. (a) Identification. An ophthalmic eye shield is a device that consists of a plastic or aluminum eye covering intended to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic eye shield. 886.4750 Section 886.4750...

  13. 21 CFR 886.3100 - Ophthalmic tantalum clip.

    Science.gov (United States)

    2010-04-01

    ... blood vessels in the eye. (b) Classification. Class II (special controls). The device is exempt from the...) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3100 Ophthalmic tantalum clip. (a) Identification. An ophthalmic tantalum clip is a malleable metallic device intended to be implanted permanently...

  14. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  15. 21 CFR 886.1405 - Ophthalmic trial lens set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens set. 886.1405 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1405 Ophthalmic trial lens set. (a) Identification. An ophthalmic trial lens set is a device that is a set of lenses of various dioptric powers...

  16. 21 CFR 886.1415 - Ophthalmic trial lens frame.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens frame. 886.1415 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1415 Ophthalmic trial lens frame. (a) Identification. An opthalmic trial lens frame is a mechanical device intended to hold trial lenses for vision...

  17. Simple approach to prevent capsule tear-out during capsulorhexis creation in hypermature cataracts.

    Science.gov (United States)

    Robinson, Mark S; Olson, Randall J

    2015-07-01

    Capsule tear-out in hypermature cataracts (Argentinean flag sign) is a common and frustrating complication during the creation of a capsulorhexis. Completing the capsulorhexis through a small side-port incision, filling the anterior chamber with a highly viscous ophthalmic viscosurgical device such as a viscoadaptive agent, and using a 23- or 25-gauge microcapsulorhexis forceps to fill the side-port incision can reliably prevent this complication. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Ophthalmic gels: Past, present and future.

    Science.gov (United States)

    Al-Kinani, Ali A; Zidan, Ghada; Elsaid, Naba; Seyfoddin, Ali; Alani, Adam W G; Alany, Raid G

    2018-02-15

    Aqueous gels formulated using hydrophilic polymers (hydrogels) along with those based on stimuli responsive polymers (in situ gelling or gel forming systems) continue to attract increasing interest for various eye health-related applications. They allow the incorporation of a variety of ophthalmic pharmaceuticals to achieve therapeutic levels of drugs and bioactives at target ocular sites. The integration of sophisticated drug delivery technologies such as nanotechnology-based ones with intelligent and environment responsive systems can extend current treatment duration to provide more clinically relevant time courses (weeks and months instead of hours and days) which will inevitably reduce dose frequency, increase patient compliance and improve clinical outcomes. Novel applications and design of contact lenses and intracanalicular delivery devices along with the move towards integrating gels into various drug delivery devices like intraocular pumps, injections and implants has the potential to reduce comorbidities caused by glaucoma, corneal keratopathy, cataract, diabetic retinopathies and age-related macular degeneration. This review describes ophthalmic gelling systems with emphasis on mechanism of gel formation and application in ophthalmology. It provides a critical appraisal of the techniques and methods used in the characterization of ophthalmic preformed gels and in situ gelling systems along with a thorough insight into the safety and biocompatibility of these systems. Newly developed ophthalmic gels, hydrogels, preformed gels and in situ gelling systems including the latest in the area of stimuli responsive gels, molecularly imprinted gels, nanogels, 3D printed hydrogels; 3D printed devices comprising ophthalmic gels are covered. Finally, new applications of gels in the production of artificial corneas, corneal wound healing and hydrogel contact lenses are described. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The Ultrachopper tip: a wound temperature study.

    Science.gov (United States)

    Barlow, William R; Pettey, Jeff; Olson, Randall J

    2013-12-01

    To determine the thermal characteristics of the Ultrachopper and its thermal properties in varied viscosurgical substances. Experimental study. Not applicable. The Ultrachopper (Alcon, Inc) tip with the Infiniti (Alcon, Inc) handpiece was attached to a thermistor and placed in a test chamber filled with either an ophthalmic viscosurgical device (OVD) or balanced salt solution (BSS). The thermistor allowed for continuous monitoring of temperature from baseline and the change that occurred over 60 seconds of continuous run time. Mean maximum temperature in each OVD exceeded 50°C over the first 25 seconds of continuous run time. The mean maximum temperature was statistically significantly higher with all OVDs (p < 0.0001) when compared with BSS. A small but statistically significant difference in mean maximum temperature was shown between Healon 5 (AMO, Inc) and Viscoat (Alcon, Inc) (p < 0.05). The linear increase in temperature was statistically significantly different with all OVDs compared with BSS (p < 0.0001). The thermal properties of the Ultrachopper tip demonstrate a heat-generating capacity that achieves published thresholds for risk for wound burn. Copyright © 2013 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  20. Are we pharmacovigilant enough in ophthalmic practice?

    Directory of Open Access Journals (Sweden)

    Ashok Dubey

    2013-01-01

    Full Text Available No drug is absolutely safe. Pharmacovigilance is the science related to detection, assessment, understanding and prevention of adverse effects or any other possible drug-related problems. The ocular medications and devices can cause localized and systemic adverse effects. Not all adverse effects are known when a drug or device is launched in market because of limitations of clinical trials. Many adverse effects are recognized due to the spontaneous reporting of the vigilant doctors who observe and report such events encountered in their practice. Despite a large ophthalmic patient population base, India does not have robust adverse drug reaction (ADR database because of lack of reporting culture. Government of India recently launched the Pharmacovigilance Programme of India (PvPI to monitor ADRs and create awareness among the healthcare professionals about the importance of ADRs. Suspecting and reporting a possible drug reaction is very important in developing a safe and rational ophthalmic practice.

  1. Toxic Anterior Segment Syndrome (TASS

    Directory of Open Access Journals (Sweden)

    Özlem Öner

    2011-12-01

    Full Text Available Toxic anterior segment syndrome (TASS is a sterile intraocular inflammation caused by noninfectious substances, resulting in extensive toxic damage to the intraocular tissues. Possible etiologic factors of TASS include surgical trauma, bacterial endotoxin, intraocular solutions with inappropriate pH and osmolality, preservatives, denatured ophthalmic viscosurgical devices (OVD, inadequate sterilization, cleaning and rinsing of surgical devices, intraocular lenses, polishing and sterilizing compounds which are related to intraocular lenses. The characteristic signs and symptoms such as blurred vision, corneal edema, hypopyon and nonreactive pupil usually occur 24 hours after the cataract surgery. The differential diagnosis of TASS from infectious endophthalmitis is important. The main treatment for TASS formation is prevention. TASS is a cataract surgery complication that is more commonly seen nowadays. In this article, the possible underlying causes as well as treatment and prevention methods of TASS are summarized. (Turk J Oph thal mol 2011; 41: 407-13

  2. Diclofenac Ophthalmic

    Science.gov (United States)

    Diclofenac ophthalmic solution is used to treat eye pain, redness, and swelling in patients who are recovering ... treat clouding of the lens in the eye). Diclofenac ophthalmic solution is also used to temporarily relieve ...

  3. Are ultrasound-guided ophthalmic blocks injurious to the eye? A comparative rabbit model study of two ultrasound devices evaluating intraorbital thermal and structural changes.

    Science.gov (United States)

    Palte, Howard D; Gayer, Steven; Arrieta, Esdras; Scot Shaw, Eric; Nose, Izuru; Lee, Elizabete; Arheart, Kristopher L; Dubovy, Sander; Birnbach, David J; Parel, Jean-Marie

    2012-07-01

    Since Atkinson's original description of retrobulbar block in 1936, needle-based anesthetic techniques have become integral to ophthalmic anesthesia. These techniques are unfortunately associated with rare, grave complications such as globe perforation. Ultrasound has gained widespread acceptance for peripheral nerve blockade, but its translation to ocular anesthesia has been hampered because sonic energy, in the guise of thermal or biomechanical insult, is potentially injurious to vulnerable eye tissue. The US Food and Drug Administration (FDA) has defined guidelines for safe use of ultrasound for ophthalmic examination, but most ultrasound devices used by anesthesiologists are not FDA-approved for ocular application because they generate excessive energy. Regulating agencies state that ultrasound examinations can be safely undertaken as long as tissue temperatures do not increase >1.5°C above physiological levels. Using a rabbit model, we investigated the thermal and mechanical ocular effects after prolonged ultrasonic exposure to single orbital- and nonorbital-rated devices. In a dual-phase study, aimed at detecting ocular injury, the eyes of 8 rabbits were exposed to continuous 10-minute ultrasound examinations from 2 devices: (1) the Sonosite Micromaxx (nonorbital rated) and (2) the Sonomed VuMax (orbital rated) machines. In phase I, temperatures were continuously monitored via thermocouples implanted within specific eye structures (n = 4). In phase II the eyes were subjected to ultrasonic exposure without surgical intervention (n = 4). All eyes underwent light microscopy examinations, followed at different intervals by histology evaluations conducted by an ophthalmic pathologist. Temperature changes were monitored in the eyes of 4 rabbits. The nonorbital-rated transducer produced increases in ocular tissue temperature that surpassed the safe limit (increases >1.5°C) in the lens of 3 rabbits (at 5.0, 5.5, and 1.5 minutes) and cornea of 2 rabbits (both at 1

  4. Basics of Sterile Compounding: Ophthalmic Preparations, Part 1: Ophthalmic Solutions.

    Science.gov (United States)

    Allen, Loyd V

    2016-01-01

    Ophthalmic preparations are used to treat allergies, bacterial and viral infections, glaucoma, and numerous other eye conditions. When the eye's natural defensive mechanisms are compromised or overcome, an ophthalmic preparation, in a solution, suspension, or ointment form, may be indicated, with solutions being the most common form used to deliver a drug to the eye. This article provides a general discussion on ophthalmic preparations and specifically discusses the preparation of solutions. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  5. Digital video recording and archiving in ophthalmic surgery

    Directory of Open Access Journals (Sweden)

    Raju Biju

    2006-01-01

    Full Text Available Currently most ophthalmic operating rooms are equipped with an analog video recording system [analog Charge Couple Device camera for video grabbing and a Video Cassette Recorder for recording]. We discuss the various advantages of a digital video capture device, its archiving capabilities and our experience during the transition from analog to digital video recording and archiving. The basic terminology and concepts related to analog and digital video, along with the choice of hardware, software and formats for archiving are discussed.

  6. Noninvasive Dry Eye Assessment Using High-Technology Ophthalmic Examination Devices.

    Science.gov (United States)

    Yamaguchi, Masahiko; Sakane, Yuri; Kamao, Tomoyuki; Zheng, Xiaodong; Goto, Tomoko; Shiraishi, Atsushi; Ohashi, Yuichi

    2016-11-01

    Recently, the number of dry eye cases has dramatically increased. Thus, it is important that easy screening, exact diagnoses, and suitable treatments be available. We developed 3 original and noninvasive assessments for this disorder. First, a DR-1 dry eye monitor was used to determine the tear meniscus height quantitatively by capturing a tear meniscus digital image that was analyzed by Meniscus Processor software. The DR-1 meniscus height value significantly correlated with the fluorescein meniscus height (r = 0.06, Bland-Altman analysis). At a cutoff value of 0.22 mm, sensitivity of the dry eye diagnosis was 84.1% with 90.9% specificity. Second, the Tear Stability Analysis System was used to quantitatively measure tear film stability using a topographic modeling system corneal shape analysis device. Tear film stability was objectively and quantitatively evaluated every second during sustained eye openings. The Tear Stability Analysis System is currently installed in an RT-7000 autorefractometer and topographer to automate the diagnosis of dry eye. Third, the Ocular Surface Thermographer uses ophthalmic thermography for diagnosis. The decrease in ocular surface temperature in dry eyes was significantly greater than that in normal eyes (P eye opening. Decreased corneal temperature correlated significantly with the tear film breakup time (r = 0.572; P dry eye, sensitivity was 0.83 and specificity was 0.80 after 10 seconds. This article describes the details and potential of these 3 noninvasive dry eye assessment systems.

  7. 75 FR 54492 - Ophthalmic and Topical Dosage Form New Animal Drugs; Gentamicin and Betamethasone Ophthalmic...

    Science.gov (United States)

    2010-09-08

    ... Ophthalmic Solution AGENCY: Food and Drug Administration, HHS. ACTION: Final rule; technical amendment... acetate ophthalmic solution. This action is being taken to comply with the Federal Food, Drug, and... GENTOCIN DURAFILM (gentamicin sulfate and betamethasone acetate) Ophthalmic Solution, sponsored by Intervet...

  8. Radioactivity measurements for some ophthalmic glasses

    International Nuclear Information System (INIS)

    Badawy, W.M.; Ali, E.M.; Gomaa, M.A.; Hussein, A

    2007-01-01

    The main aim of the present work is to implant the latest ICRP/IAEA recommendations related to exemption and clearness to the Ophthalmic Glass. As consumer product, glass lenses may contain trace quantities of uranium, thorium and potassium. Glass lenses under investigation were monitored for the detection of gamma rays and beta particles using radiation measuring devices. Using high purity germanium detector radioactivity concentration was estimated in Bq/kg. Activity concentration of 226 Ra, Th-232 and K-40 were determined using the energy gamma lines of 2l4 Pb (352 keV), 212 Pb (238 keV) and 1460 keV gamma line for 40 K respectively .Experimental results showed that radioactivity concentration for radium -226 varies from 0.19 to 4.98 Bq/kg of radium-226, from to 0.18 to 2.83 Bq/kg for thorium -232 and from 0.8 to 1.13 Bq/kg for potassium. Implementing new ICRP recommendation of exemption and clearness indicated that several Ophthalmic Glass should not be in use

  9. Thermal study of bare tips with various system parameters and incision sizes.

    Science.gov (United States)

    Osher, Robert H; Injev, Valentine P

    2006-05-01

    To identify major and minor surgeon-controlled parameters that affect incision temperature when performing microincision lens removal using the Alcon Infiniti Vision System. In vitro research and development laboratory, Alcon Research, Irvine, California, USA. Phacoemulsification was performed in eye-bank cadaver eyes and the following parameters evaluated: incision, duty cycle, ultrasound (US) power, aspiration flow rate (AFR), vacuum, pulse, bottle height and balanced salt solution temperature, and tip design/size. Each parameter was varied while the others remained constant. The resulting temperature of the incision and US tip was measured using a thermal camera. Major contributors to elevated incision temperature included incision size, US power, duty cycle, AFR, vacuum setting, tip design, and presence of an ophthalmic viscosurgical device (OVD). Minor contributors included pulse frequency, bottle height, and temperature of the infusate. Microincision lens removal can be performed at safe temperatures with the knowledgeable selection of surgeon-controlled parameters.

  10. Ophthalmic Disorders in Adults with Down Syndrome

    Directory of Open Access Journals (Sweden)

    Sharon J. Krinsky-McHale

    2012-01-01

    Full Text Available A myriad of ophthalmic disorders is associated with the phenotype of Down syndrome including strabismus, cataracts, and refractive errors potentially resulting in significant visual impairment. Ophthalmic sequelae have been extensively studied in children and adolescents with Down syndrome but less often in older adults. In-depth review of medical records of older adults with Down syndrome indicated that ophthalmic disorders were common. Cataracts were the most frequent ophthalmic disorder reported, followed by refractive errors, strabismus, and presbyopia. Severity of intellectual disability was unrelated to the presence of ophthalmic disorders. Also, ophthalmic disorders were associated with lower vision-dependent functional and cognitive abilities, although not to the extent that was expected. The high prevalence of ophthalmic disorders highlights the need for periodic evaluations and individualized treatment plans for adults with Down syndrome, in general, but especially when concerns are identified.

  11. A clinical comparison of safety and efficacy in phacoemulsification with versus without ophthalmic viscoelastic device.

    Science.gov (United States)

    Kugu, Suleyman; Erdogan, Gurkan; Sahin Sevim, M; Ozerturk, Yusuf

    2015-03-01

    To evaluate in a comparative manner the safety and efficacy of 1.0% sodium-Hyaluronate used during capsulorhexis and intraocular lens (IOL) implantation in phacoemulsification surgery. 1.0% sodium-Hyaluronate, which is commonly used as one of the ophthalmic viscoelastic devices, was compared to intraocular irrigating solution, which can bring up these effects. In addition, the effect of both methods on occurring corneal endothelial cell (CEC) loss was investigated. Each group comprised 19 eyes. The mean preoperative CEC density was 2525.68 ± 181.85 in Group H and 2514.16 ± 174.59 in Group V; no statistically significant difference was found between the groups (p > 0.05). Preoperative and postoperative first and twelfth week CEC densities were 2438.21 ± 198.12 (p  0.05). Although it was found that there was no statistically difference in terms of preventing CEC loss between 1.0% sodium-Hyaluronate and the irrigation method during phacoemulsification, it was observed clinically that 1.0% sodium-hyaluronate can make the procedure easy, safer, very helpful, especially for understanding phacoemulsification.

  12. Topical ophthalmic NSAIDs: a discussion with focus on nepafenac ophthalmic suspension

    OpenAIRE

    Gaynes, Bruce I; Onyekwuluje, Anne

    2008-01-01

    Bruce I Gaynes1,2, Anne Onyekwuluje11Departments of Ophthalmology and 2Pharmacology, Rush College of Medicine, Chicago, Illinois, USAAbstract: The removal of diclofenac sodium ophthalmic solution as a viable pharmaceutical entity in September 1999 from the US market spurred considerable interest in the general safety and effectiveness of topical ophthalmic NSAIDs for treatment of anterior segment inflammation. In late 1999 the use of topical ocular NSAIDs declined in the US as a result of inc...

  13. Viscoless microincision cataract surgery

    Directory of Open Access Journals (Sweden)

    Guy Sallet

    2008-06-01

    Full Text Available Guy SalletDepartment of Opthamology, Aalsters Stedelijk Ziekenhuis, BelgiumAbstract: A cataract surgery technique is described in which incisions, continuous circular capsulorhexis and hydrodissection are made without the use of any viscoelastics. Two small incisions are created through which the different parts of the procedure can take place, maintaining a stable anterior chamber under continuous irrigation. Subsequent bimanual phacoemulsification can be done through these microincisions. At the end of the procedure, an intraocular lens can be inserted through the self-sealing incision under continuous irrigation. 50 consecutive cataract patients were operated on without the use of viscoelastics and then compared with a group of 50 patients who had been helped with viscoelastics. No difference in outcome, endothelial cell count or pachymetry was noted between the two groups. No intraoperative complication was encountered. Viscoless cataract surgery was a safe procedure with potential advantages.Keywords: ophthalmic visco-surgical device, viscoless cataract surgery, microincision

  14. Dosimetry of Sr-90 ophthalmic applicators

    International Nuclear Information System (INIS)

    Reft, C.S.; Kuchnir, F.T.; Rosenberg, I.; Myrianthopoulos, L.C.

    1990-01-01

    Sr-90 ophthalmic applicators are commonly used for the treatment of superficial eye disorders. Although a variety of dosimetric devices such as film, thermoluminescent dosimeters (TLD's), ion chambers, and radiochromic foils have been used to measure the peak dose at the applicator surface, there is no internationally agreed upon calibration procedure. Recently, large discrepancies among calibrations of the same applicator at three institutions have been reported. Here we describe a technique to obtain the peak dose rate at the applicator surface using LiF TLD's. The technique can be used for the calibration of flat as well as curved surface applicators. Results for two flat and three concave applicators are presented. Our measurement of the surface dose rate for one of the flat applicators is compared with those obtained by four other institutions, each using different dosimetric devices

  15. 21 CFR 524.1982 - Proparacaine hydrochloride ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Proparacaine hydrochloride ophthalmic solution... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1982 Proparacaine hydrochloride ophthalmic solution. (a) Specifications. The drug is...

  16. 21 CFR 524.390b - Chloramphenicol ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Chloramphenicol ophthalmic solution. 524.390b... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.390b Chloramphenicol ophthalmic solution. (a) Specifications. Each milliliter contains 5...

  17. 21 CFR 524.1044a - Gentamicin ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Gentamicin ophthalmic solution. 524.1044a Section... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1044a Gentamicin ophthalmic solution. (a) Specifications. Each milliliter of sterile aqueous...

  18. Communication: an ophthalmic practice issue.

    Science.gov (United States)

    Whitton, S J

    1995-12-01

    In the 1990's communication becomes an ophthalmic practice issue. The present ophthalmic climate of cost containment, downsizing, budget cuts, and lack of appreciation of contributions, results in a low staff morale. Recognition of the effects of job satisfaction and productivity led one group to seek solutions. A communication task force was formed to identify problems and the appropriate interventions.

  19. The improvement of dry eye after cataract surgery by intraoperative using ophthalmic viscosurgical devices on the surface of cornea

    Science.gov (United States)

    He, Yuan; Li, Jia; Zhu, Jingfen; Jie, Ying; Wang, Ningli; Wang, Jun

    2017-01-01

    Abstract Backgroud: This study aimed to investigate the protective effect of intraoperative used hydroxypropyl methylcellulose (HPMC 2%) on the ocular surface after cataract surgery. Methods: A total of 149 eyes (149 patients) diagnosed with age-related cataract, age 69.19 ± 9.74 years, were enrolled in this prospective, parallel-design, continuous, randomised controlled study. Patients were randomly assigned to receive HPMC 2% (study group) or balanced salt solution (control group) during the surgery to moisturize the cornea surface. The Ocular Surface Disease Index, Schirmer test without topical anesthetics, tear break-up time, and corneal fluorescein staining were assessed preoperatively, 1 day, 1 week, and 1 month after the surgery, respectively. Results: The Schirmer test value of male patients in the study group at 1 week postoperation was higher than that of male patients in the control group (P = .019). For patients diagnosed with dry eye before the surgery, Schirmer test value in the male patients in the study group at 1 month after surgery was higher than that in the male patients in the control group (P = .037). Furthermore, for the cluster of preoperative dry eye patients whose surgical time was longer than median, corneal fluorescein staining of the patients in the study group was superior to that of the patients in the control group (P = .032). Conclusion: Intraoperative use of HPMC 2% on the cornea surface could improve clinical outcomes of tear film and ocular surface health to some degree, especially in the patients diagnosed with dry eye before the surgery, male patients, and patients whose surgical time was relatively longer. PMID:29390284

  20. Sildenafil dilates ophthalmic artery in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Akeel AMH Zwain

    2013-08-01

    Full Text Available Background: Conflicting reports exist on the effect of sildenafil on ophthalmic artery blood flow; many visual disturbances due to vascular insult were reported with the use of sildenafil in diabetic patients like nonarteritic ischemic optic neuropathy. Objectives: The present work aimed to investigate whether sildenafil modulates ophthalmic artery vasoreactivity in patients with type 2 diabetes mellitus. Literature reports on this aspect are lacking. Methods: A total of 35 male subjects were enrolled in this study, 18 with type 2 diabetes mellitus matched with 17 normal individuals. Ophthalmic artery was insonated through a transorbital window using colored Doppler equipment with transcranial Doppler facility. Ophthalmic artery reactivity was assessed using breath holding/hyperventilation test, before and after giving 50 mg oral sildenafil. Results: It was found that in both normal subjects and diabetic patients, sildenafil increased baseline control of mean flow velocity of ophthalmic artery significantly (p 0.05 after sildenafil, in normal and diabetic groups. There was a significant increase of resistive index of ophthalmic artery flow in diabetic patients compared with that of normal subject (p < 0.05. Sildenafil decreased resistive index of ophthalmic artery flow significantly only in diabetic patients (p < 0.05. Conclusion: Sildenafil increased MFVopa, but had no significant effect on vasoreactivity of ophthalmic artery; sildenafil decreased resistive index only in type 2 diabetic patients.

  1. Dose uniformity of loteprednol etabonate ophthalmic gel (0.5% compared with branded and generic prednisolone acetate ophthalmic suspension (1%

    Directory of Open Access Journals (Sweden)

    Marlowe ZT

    2013-12-01

    Full Text Available Zora T Marlowe, Stephen R DavioPharmaceutical Product Development, Global Pharmaceutical Research and Development, Bausch and Lomb, Inc, Rochester, NY, USAIntroduction: Loteprednol etabonate (LE ophthalmic gel 0.5% (Lotemax® is a new polycarbophil-based, nonsettling topical ophthalmic formulation. The formulation is a semisolid gel at rest and a shear thinning fluid when expressed through a dropper tip. The present study was undertaken to determine how the nonsettling character of LE ophthalmic gel affects dose uniformity. Prednisolone acetate ophthalmic suspension 1% (Pred Forte® and a generic prednisolone acetate suspension 1% were used as comparators.Methods: Drug concentrations of LE ophthalmic gel, Pred Forte, and a generic prednisolone acetate suspension were determined following simulated dosing – consisting of 2 drops, expressed four times daily for 2 weeks, with bottles that were shaken or not shaken immediately prior to expressing the drops. Drug concentrations were determined using a reverse-phase high-performance liquid chromatography (HPLC method and reported as a percentage of the declared (labeled concentration. Comparative kinetics of drug particle sedimentation were also determined for each formulation, using dispersion analysis under gravity.Results: Mean drug concentrations in drops of all three formulations were within a few percentage points of the declared concentration when the bottles were shaken for 5 seconds prior to dispensing. Only LE ophthalmic gel showed consistent and on-target concentrations when the bottles were unshaken prior to dispensing, with a mean (standard deviation [SD] percent declared concentration of 102% (1.92% over the 2-week dosing regimen. Drug concentrations for the branded and generic prednisolone acetate suspensions following expression from unshaken bottles were highly variable (overall relative SDs of 16.8% and 20.3%, respectively, with mean concentrations for both falling significantly

  2. Dose uniformity of loteprednol etabonate ophthalmic gel (0.5%) compared with branded and generic prednisolone acetate ophthalmic suspension (1%).

    Science.gov (United States)

    Marlowe, Zora T; Davio, Stephen R

    2014-01-01

    Loteprednol etabonate (LE) ophthalmic gel 0.5% (Lotemax®) is a new polycarbophil-based, nonsettling topical ophthalmic formulation. The formulation is a semisolid gel at rest and a shear thinning fluid when expressed through a dropper tip. The present study was undertaken to determine how the nonsettling character of LE ophthalmic gel affects dose uniformity. Prednisolone acetate ophthalmic suspension 1% (Pred Forte®) and a generic prednisolone acetate suspension 1% were used as comparators. Drug concentrations of LE ophthalmic gel, Pred Forte, and a generic prednisolone acetate suspension were determined following simulated dosing - consisting of 2 drops, expressed four times daily for 2 weeks, with bottles that were shaken or not shaken immediately prior to expressing the drops. Drug concentrations were determined using a reverse-phase high-performance liquid chromatography (HPLC) method and reported as a percentage of the declared (labeled) concentration. Comparative kinetics of drug particle sedimentation were also determined for each formulation, using dispersion analysis under gravity. Mean drug concentrations in drops of all three formulations were within a few percentage points of the declared concentration when the bottles were shaken for 5 seconds prior to dispensing. Only LE ophthalmic gel showed consistent and on-target concentrations when the bottles were unshaken prior to dispensing, with a mean (standard deviation [SD]) percent declared concentration of 102% (1.92%) over the 2-week dosing regimen. Drug concentrations for the branded and generic prednisolone acetate suspensions following expression from unshaken bottles were highly variable (overall relative SDs of 16.8% and 20.3%, respectively), with mean concentrations for both falling significantly below the declared concentration for drops expressed at the beginning of the 2-week dosing regimen and significantly above the declared concentration for drops expressed near the end of the dosing

  3. 21 CFR 524.1200b - Kanamycin ophthalmic aqueous solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Kanamycin ophthalmic aqueous solution. 524.1200b... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1200b Kanamycin ophthalmic aqueous solution. (a) Specifications. The drug, which is in an aqueous...

  4. Alternative methods of ophthalmic treatment in Russia.

    Science.gov (United States)

    Vader, L

    1994-04-01

    Russian ophthalmic nurses and physicians are using alternative methods of treatment to supplement traditional eye care. As acupuncture and iridology become more popular in the United States, ophthalmic nurses need to be more knowledgeable about these treatments and the implications for patients.

  5. A new kind of monitor for ophthalmic operation

    International Nuclear Information System (INIS)

    Li, G; Wang, L L; Wang, Y; Lin, L; Jiang, W; Lu, Stephen C-Y; Besio, Walter G

    2005-01-01

    The integrity of the vision channel is often checked using VEP in order to avoiding damaging important tissue during an ophthalmic operation. But the measurement of before operations has strong side effects, it may damage the eyeball. We will introduce a new kind for monitoring ophthalmic operations in this paper. It uses visual electrical evoked potential to check the integrity of the vision access and it can monitor ophthalmic operations and avoid damaging any tissue, so it ensures the safety of the operation

  6. A new kind of monitor for ophthalmic operation

    Energy Technology Data Exchange (ETDEWEB)

    Li, G [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Wang, L L [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Wang, Y [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Lin, L [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Jiang, W [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Lu, Stephen C-Y [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Besio, Walter G [Biomedical Engineering Program, and Center for Biomedical Engineering and Rehabilitation Science Louisiana Tech. University, LA (United States)

    2005-01-01

    The integrity of the vision channel is often checked using VEP in order to avoiding damaging important tissue during an ophthalmic operation. But the measurement of before operations has strong side effects, it may damage the eyeball. We will introduce a new kind for monitoring ophthalmic operations in this paper. It uses visual electrical evoked potential to check the integrity of the vision access and it can monitor ophthalmic operations and avoid damaging any tissue, so it ensures the safety of the operation.

  7. determinants of general anaesthesia for ophthalmic surgery

    African Journals Online (AJOL)

    DR. CHARLES IMARENGIAYE

    1999-08-01

    Objectives: To study the pattern of anaesthesia for ophthalmic procedures in order to improve the scheduling of cases in the ophthalmic operating room. Methods: The surgical register of the operating room from. August 01, 1999 to July 31, 2004 was examined, to document the types of procedure, timing of surgery (elective ...

  8. Cataract surgery in patients with pseudoexfoliation syndrome: current updates

    Directory of Open Access Journals (Sweden)

    Fontana L

    2017-07-01

    Full Text Available Luigi Fontana, Marco Coassin, Alfonso Iovieno, Antonio Moramarco, Luca Cimino Ophthalmology Unit, Arcispedale Santa Maria Nuova – IRCCS, Reggio Emilia, Italy Abstract: Pseudoexfoliation is a ubiquitous syndrome of multifactorial origin affecting elderly people by increasing the risk of cataract and secondary glaucoma development. Despite modern techniques and technologies for cataract surgery, pseudoexfoliation syndrome represents a challenge for surgeons because of the increased weakness of the zonular apparatus and limited pupil dilation. Due to the inherent difficulties during surgery, the risk of vitreous loss in these patients is several times higher than in cataract patients without pseudoexfoliation. Using currently available surgical devices (ophthalmic viscosurgical device, iris retractors and ring dilators, capsular tension ring, etc., the risk of intraoperative complications may be much reduced, allowing the surgeon to handle difficult cases with greater confidence and safety. This review analyzes the methodologic approach to the patient with zonular laxity with the aim of providing useful advices to limit the risks of intraoperative and postoperative complications. From the preoperative planning, to the intraoperative management of the small pupil and phacodonesis, and to the postoperative correction of capsule phimosis and intraocular lens dislocation, a step approach to the surgical management of pseudoexfoliation patients is illustrated. Keywords: pseudoexfoliation syndrome, cataract surgery, zonular laxity, intraocular lens implant, complications

  9. Ophthalmic masquerades of the atherosclerotic carotids

    Directory of Open Access Journals (Sweden)

    Anupriya Arthur

    2014-01-01

    Full Text Available Patients with carotid atherosclerosis can present with ophthalmic symptoms. These symptoms and signs can be due to retinal emboli, hypoperfusion of the retina and choroid, opening up of collateral channels, or chronic hypoperfusion of the globe (ocular ischemic syndrome. These pathological mechanisms can produce many interesting signs and a careful history can bring out important past symptoms pointing toward the carotid as the source of the patient′s presenting symptom. Such patients are at high risk for an ischemic stroke, especially in the subsequent few days following their first acute symptom. It is important for clinicians to be familiar with these ophthalmic symptoms and signs caused by carotid atherosclerosis for making an early diagnosis and to take appropriate measures to prevent a stroke. This review elaborates the clinical features, importance, and implications of various ophthalmic symptoms and signs resulting from atherosclerotic carotid artery disease.

  10. 21 CFR 886.4350 - Manual ophthalmic surgical instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual ophthalmic surgical instrument. 886.4350 Section 886.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suturing needle, lachrymal probe, trabeculotomy probe, cornea-sclera punch, ophthalmic retractor...

  11. Treatment of neuro-ophthalmic sarcoidosis.

    Science.gov (United States)

    Frohman, Larry P

    2015-03-01

    Because of the rarity of neuro-ophthalmic sarcoidosis, there are no therapeutic guidelines based on evidence-based medicine for this disorder. Review of literature combined with personal experience. Corticosteroids are the preferred initial therapy for neuro-ophthalmic sarcoidosis. If patients cannot tolerate the requisite dose of corticosteroid needed to control their disease, or if corticosteroids fail to adequately control the disease process, the choices of a second agent are based on the consideration of rapidity of clinical response and the safety profile. Although methotrexate and mycophenolate mofetil are the medications that are often selected after corticosteroid failure, more rapidly acting agents that have been used are infliximab and intravenous cyclophosphamide.

  12. Audit of Referrals to an Ophthalmic Outpatient Clinic of a Tertiary ...

    African Journals Online (AJOL)

    Objectives: To determine the referral pattern and assess the quality and accuracy of referral letters to the ophthalmic outpatient clinic of University of Nigeria Teaching Hospital, Enugu. Methods: This study is a prospective cross-sectional survey of all new ophthalmic referrals to the ophthalmic outpatient clinic at University of ...

  13. Degree and duration of corneal anesthesia after topical application of 0.4% oxybuprocaine hydrochloride ophthalmic solution in ophthalmically normal dogs.

    Science.gov (United States)

    Douet, Jean-Yves; Michel, Julien; Regnier, Alain

    2013-10-01

    To assess the anesthetic efficacy and local tolerance of topically applied 0.4% oxybuprocaine ophthalmic solution to in dogs and compare its effects with those of 1% tetracaine solution. 34 ophthalmically normal Beagles. Dogs were assigned to 2 groups, and baseline corneal touch threshold (CTT) was measured bilaterally with a Cochet-Bonnet aesthesiometer. Dogs of group 1 (n = 22) received a single drop of 0.4% oxybuprocaine ophthalmic solution in one eye and saline (0.9% NaCl) solution (control treatment) in the contralateral eye. Dogs of group 2 (n = 12) received a single drop of 0.4% oxybuprocaine ophthalmic solution in one eye and 1% tetracaine ophthalmic solution in the contralateral eye. The CTT of each eye was measured 1 and 5 minutes after topical application and then at 5-minute intervals until 75 minutes after topical application. CTT changes over time differed significantly between oxybuprocaine-treated and control eyes. After instillation of oxybuprocaine, maximal corneal anesthesia (CTT = 0) was achieved within 1 minute, and CTT was significantly decreased from 1 to 45 minutes, compared with the baseline value. No significant difference in onset, depth, and duration of corneal anesthesia was found between oxybuprocaine-treated and tetracaine-treated eyes. Conjunctival hyperemia and chemosis were detected more frequently in tetracaine-treated eyes than in oxybuprocaine-treated eyes. Topical application of oxybuprocaine and tetracaine similarly reduced corneal sensitivity in dogs, but oxybuprocaine was less irritating to the conjunctiva than was tetracaine.

  14. Diquafosol ophthalmic solution 3 %: a review of its use in dry eye.

    Science.gov (United States)

    Keating, Gillian M

    2015-05-01

    Diquafosol ophthalmic solution 3 % (Diquas(®)) is a P2Y2 receptor agonist that promotes tear fluid and mucin secretion and is currently approved in Japan and South Korea for the treatment of dry eye. In randomized, double-blind, multicentre trials in patients with dry eye, significantly greater improvements in fluorescein and rose bengal staining scores were seen with diquafosol ophthalmic solution 3 % than with placebo, and diquafosol ophthalmic solution 3 % was noninferior to sodium hyaluronate ophthalmic solution 0.1 % in terms of the improvement in the fluorescein staining score and more effective than sodium hyaluronate ophthalmic solution 0.1 % in terms of the improvement in the rose bengal staining score. The efficacy of diquafosol ophthalmic solution 3 % in the treatment of dry eye was maintained in the longer term, with improvements also seen in subjective dry eye symptoms, and was also shown in a real-world setting. Diquafosol ophthalmic solution 3 % also demonstrated efficacy in various specific dry eye disorders, including aqueous-deficient dry eye, short tear film break-up time dry eye, obstructive meibomian gland dysfunction, dry eye following laser in situ keratomileusis surgery and dry eye following cataract surgery, as well as in contact lens wearers and visual display terminal users. Diquafosol ophthalmic solution 3 % was generally well tolerated in patients with dry eye, with eye irritation the most commonly reported adverse event. In conclusion, diquafosol ophthalmic solution 3 % is a useful option for the treatment of dry eye.

  15. Rate of bacterial eradication by ophthalmic solutions of fourth-generation fluoroquinolones.

    Science.gov (United States)

    Callegan, Michelle C; Novosad, Billy D; Ramadan, Raniyah T; Wiskur, Brandt; Moyer, Andrea L

    2009-04-01

    Antibacterial activity of ophthalmic fourth-generation fluoroquinolones has traditionally been evaluated by comparing only their active ingredients, gatifloxacin and moxifloxacin. However, ophthalmic formulations of fourth-generation fluoroquinolones differ in terms of the inclusion of preservatives. While gatifloxacin ophthalmic solution 0.3% (Zymar; Allergan, Inc., Irvine, CA, USA) contains 0.005% benzalkonium chloride (BAK), moxifloxacin ophthalmic solution 0.5% (Vigamox; Alcon Laboratories, Inc., Fort Worth, TX, USA) is preservative-free. Recent studies have demonstrated that the presence of BAK dramatically affects the antibacterial activity of the ophthalmic formulation of gatifloxacin. This study was designed to compare the kill rates of ophthalmic solutions of fourth-generation fluoroquinolones against isolates of common ocular bacterial pathogens. Approximately 5.6 log(10) colony-forming units (CFU)/mL of Haemophilus influenzae (n=1), Streptococcus pneumoniae (n=1), Staphylococcus aureus (n=2), methicillin-resistant Staphylococcus aureus (MRSA) (n=4), methicillinresistant Staphylococcus epidermidis (MRSE) (n=4), and fluoroquinolone-resistant S. epidermidis (n=1) were incubated with ophthalmic solutions of either gatifloxacin or moxifloxacin. Viable bacteria were quantified at specific time points up to 60 minutes. Gatifloxacin 0.3% completely eradicated H. influenzae and Strep. pneumoniae in 5 minutes, one of two S. aureus isolates in 15 minutes, and the other S. aureus isolate in 60 minutes. Gatifloxacin 0.3% completely killed all MRSA, MRSE, and fluoroquinolone-resistant S. epidermidis isolates in 15 minutes. Moxifloxacin 0.5% completely eradicated Strep. pneumoniae and one of four MRSA isolates in 60 minutes. All other isolates incubated with moxifloxacin 0.5% retained viable bacteria ranging from 1.8 to 4.4 log(10) CFU/mL. The ophthalmic solution of gatifloxacin 0.3% eradicated bacteria that frequently cause postoperative ocular infections

  16. 76 FR 30176 - Dermatologic and Ophthalmic Drugs Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-05-24

    ... committee will discuss biologics license application (BLA) 125387, aflibercept ophthalmic solution, proposed...] Dermatologic and Ophthalmic Drugs Advisory Committee; Notice of Meeting AGENCY: Food and Drug Administration...: Dermatologic and Ophthalmic Drugs Advisory Committee. General Function of the Committee: To provide advice and...

  17. Development and Effects of FTY720 Ophthalmic Solution on Corneal Allograft Survival.

    Science.gov (United States)

    Liu, Zhaochuan; Lin, Haotian; Huang, Chulong; Chen, Wan; Xiang, Wu; Geng, Yu; Chen, Weirong

    2015-11-12

    Fingolimod (FTY720), a novel class of sphingosine 1-phosphate receptor modulators, has received special interest among ophthalmologists, particularly given that oral administration of FTY720 has proven to effectively treat corneal graft rejection in animal models. However, no studies have examined the performance of FTY720 as an ophthalmic solution in reducing corneal rejection in high-risk corneal rejection models, and the stability and ocular irritation profile of FTY720 ophthalmic solution are also unknown. Thus, we developed 0.1%, 0.2% and 0.5% FTY720 ophthalmic solutions and evaluated their chemical stabilities under various storage conditions with high- performance liquid chromatography. To investigate the ocular irritancy of the FTY720 ophthalmic solution, New Zealand albino rabbits were subjected to the Draize test. Furthermore, classic, well-established rat allogenic penetrating keratoplasty models were used to investigate the anti-rejection efficacy of the tested FTY720 ophthalmic solutions. We found that the non-irritating 0.5% FTY720 ophthalmic solution could prolong corneal allograft survival in rats with significant efficacy for about one month. Furthermore, no significant concentration changes occurred in any of the types of FTY720 ophthalmic solutions within three months. These results revealed crucial profiles of FTY720 ophthalmic solutions and warrant further investigation and optimization of FTY720 in the anti-rejection therapy after keratoplasty.

  18. Lifitegrast Ophthalmic Solution 5%: A Review in Dry Eye Disease.

    Science.gov (United States)

    Keating, Gillian M

    2017-02-01

    Lifitegrast is a novel small molecule integrin antagonist that blocks the binding of intercellular adhesion molecule 1 (ICAM-1) to lymphocyte function-associated antigen 1 (LFA-1). Lifitegrast ophthalmic solution 5% (Xiidra™) was recently approved in the USA for the treatment of dry eye disease. The efficacy of lifitegrast ophthalmic solution 5% was compared with vehicle in a 12-week phase 2 study and three 12-week phase 3 studies (OPUS-1, OPUS-2 and OPUS-3) in patients with dry eye disease. Taken as a whole, results of these trials support the treatment effect of lifitegrast ophthalmic solution 5% in improving a symptom of dry eye disease (i.e. the change from baseline to day 84 in the eye dryness visual analogue scale score) and a sign of dry eye disease (i.e. the change from baseline to day 84 in the inferior corneal fluorescein staining score). Lifitegrast ophthalmic solution 5% was generally well tolerated. In conclusion, lifitegrast ophthalmic solution 5% provides a new option for the treatment of dry eye disease.

  19. Allergic Contact Dermatitis to Ophthalmic Medications: Relevant Allergens and Alternative Testing Methods.

    Science.gov (United States)

    Grey, Katherine R; Warshaw, Erin M

    Allergic contact dermatitis is an important cause of periorbital dermatitis. Topical ophthalmic agents are relevant sensitizers. Contact dermatitis to ophthalmic medications can be challenging to diagnose and manage given the numerous possible offending agents, including both active and inactive ingredients. Furthermore, a substantial body of literature reports false-negative patch test results to ophthalmic agents. Subsequently, numerous alternative testing methods have been described. This review outlines the periorbital manifestations, causative agents, and alternative testing methods of allergic contact dermatitis to ophthalmic medications.

  20. Readability assessment of online ophthalmic patient information.

    Science.gov (United States)

    Edmunds, Matthew R; Barry, Robert J; Denniston, Alastair K

    2013-12-01

    Patients increasingly use the Internet to access information related to their disease, but poor health literacy is known to impact negatively on medical outcomes. Multiple agencies have recommended that patient-oriented literature be written at a fourth- to sixth-grade (9-12 years of age) reading level to assist understanding. The readability of online patient-oriented materials related to ophthalmic diagnoses is not yet known. To assess the readability of online literature specifically for a range of ophthalmic conditions. Body text of the top 10 patient-oriented websites for 16 different ophthalmic diagnoses, covering the full range of ophthalmic subspecialties, was analyzed for readability, source (United Kingdom vs non-United Kingdom, not for profit vs commercial), and appropriateness for sight-impaired readers. Four validated readability formulas were used: Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Fog Index (GFOG). Data were compared with the Mann-Whitney test (for 2 groups) and Kruskal-Wallis test (for more than 2 groups) and correlation was assessed by the Spearman r. None of the 160 webpages had readability scores within published guidelines, with 83% assessed as being of "difficult" readability. Not-for-profit webpages were of significantly greater length than commercial webpages (P = .02) and UK-based webpages had slightly superior readability scores compared with those of non-UK webpages (P = .004 to P readability formula used). Of all webpages evaluated, only 34% included facility to adjust text size to assist visually impaired readers. To our knowledge, this is the first study to assess readability of patient-focused webpages specifically for a range of ophthalmic diagnoses. In keeping with previous studies in other medical conditions, we determined that readability scores were inferior to those recommended, irrespective of the measure used. Although readability is only one

  1. Bilateral IgG4-related ophthalmic disease: a strong indication for systemic imaging.

    Science.gov (United States)

    Wu, Albert; Andrew, Nicholas H; McNab, Alan A; Selva, Dinesh

    2016-10-01

    To investigate whether bilateral or unilateral IgG4-related ophthalmic disease (IgG4-ROD) is associated with extra-ophthalmic IgG4-related disease (IgG4-RD). Twin-centre retrospective observational case series of biopsy-confirmed IgG4-ROD. Clinical and radiology data were reviewed for laterality of IgG4-ROD and presence of extra-ophthalmic disease. The literature was reviewed for case series of IgG4-ROD. 40 IgG4-ROD cases were identified, with median follow-up of 36 months. At diagnosis of IgG4-ROD, all cases were screened for extra-ophthalmic disease with physical examination and blood testing. Systemic imaging was performed in 20 (50%) cases due to clinical suspicion of extra-ophthalmic disease. Of the 21 unilateral IgG4-ROD cases, 3 (14%) had extra-ophthalmic involvement. Of the 19 bilateral cases, 15 (79%) had extra-ophthalmic involvement. Extra-ophthalmic involvement was strongly associated with bilateral IgG4-ROD (pIgG4-ROD is strongly associated with extra-ophthalmic IgG4-RD. We recommend that imaging of the neck, chest, abdomen and pelvis be performed for all bilateral cases. Systemic imaging should also be considered in unilateral cases as a significant proportion of these patients will also have extra-ophthalmic disease. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Diquafosol ophthalmic solution for dry eye treatment.

    Science.gov (United States)

    Nakamura, Masatsugu; Imanaka, Takahiro; Sakamoto, Asuka

    2012-07-01

    There has been rapid progress in our understanding of dry eye pathogenesis, as well as the development of improved diagnostic clinical tests. Various types of dry eye treatment drugs have been developed. This review summarizes the basic and clinical research carried out in the development of diquafosol for ophthalmic use. Diquafosol is a dinucleotide, purinoreceptor P2Y(2) receptor agonist. Basic pharmacological studies have shown that it acts on P2Y(2) receptors at the ocular surface, to promote tear and mucin secretion via elevated intracellular Ca(2+) concentrations. Diquafosol also improves tear and mucin secretion in experimental dry eye models. Based on the results of laboratory experiments, the authors conducted a series of clinical studies in patients with dry eye disease. Diquafosol was effective in the treatment of dry eye disease at an optimal dose of 3% six times a day. In comparison to commercially available 0.1% sodium hyaluronate ophthalmic solution, 3% diquafosol ophthalmic solution showed non-inferiority in improving corneal fluorescein staining scores and superiority in improving keratoconjunctival Rose Bengal staining scores. Diquafosol ophthalmic solution has a novel mechanism of action that is characterized by its stimulatory effects on tear and mucin secretion. This drug has the potential to be effective in patients with tear film instability and short break-up time type of dry eye, which are essential factors in dry eye pathogenesis.

  3. Comparison of corneal safety and intraocular pressure-lowering effect of tafluprost ophthalmic solution with other prostaglandin ophthalmic solutions.

    Science.gov (United States)

    Kumagami, Takeshi; Wakiyama, Harumi; Kusano, Mao; Kajiyama, Ayano; Miura, Yoko; Uematsu, Masafumi; Yoneda, Ai; Kurihara, Junko; Suzuma, Kiyoshi; Kitaoka, Takashi

    2014-05-01

    The benzalkonium chloride (BAK) content of tafluprost ophthalmic solution (Tapros(®): tafluprost) has been reduced to balance corneal safety and preservative effectiveness (old formulation: 0.01%; new formulation: 0.001%). However, no reports have been published on its clinical effect. Therefore, we conducted a clinical research study to compare the safety of BAK-reduced tafluprost on the ocular surface with other prostaglandin ophthalmic solutions. This clinical study included 28 glaucoma patients (28 eyes) with a treatment history of latanoprost ophthalmic solution (Xalatan(®)) or travoprost ophthalmic solution (Travatan Z(®)), who presented with corneal epithelial disorders. The subjects were switched to BAK-reduced tafluprost, and its effect on the ocular surface was examined after 1 and 2 months of treatment [using fluorescein staining score, hyperemia, tear film breakup time, and intraocular pressure (IOP) lowering]. In all analyzed subjects (N=27), the fluorescein staining score was significantly improved after switching to BAK-reduced tafluprost (P<0.0001). Conversely, the IOP-lowering effect was not notably changed. The subjects switched from latanoprost (n=10) showed significant improvement in fluorescein staining score (P<0.05) as well as in IOP lowering (P<0.01). The subjects switched from travoprost (n=17) also showed significant improvement in fluorescein staining score (P<0.001), but without a significant change in IOP lowering. Tafluprost with reduced BAK has potential as a superior antiglaucoma drug, not only for its IOP-lowering effect, but also for its good corneal safety profile.

  4. Comparison of systemic absorption between ofloxacin ophthalmic in situ gels and ofloxacin conventional ophthalmic solutions administration to rabbit eyes by HPLC-MS/MS.

    Science.gov (United States)

    Li, Jiawei; Zhao, Hainan; Okeke, Chukwunweike Ikechukwu; Li, Lin; Liu, Zhidong; Yin, Zhongpeng; Zhuang, Pengwei; Sun, Jingtong; Wu, Tao; Wang, Meng; Li, Nan; Pi, Jiaxin; Zhang, Qian; Zhang, Rui; Ma, Li; Pang, Xiaochen; Liu, Zhanbiao; Zhang, Li; Fan, Lili

    2013-06-25

    In recent years, many pharmaceutical scientists have focused on developing the in situ gel-forming systems to overcome the poor bioavailability and therapeutic response exhibited by conventional ophthalmic solutions due to rapid pre-corneal elimination of the drug. The present work was to compare the systemic absorptions of ophthalmic ofloxacin in situ gel with the conventional ofloxacin eye drop after topical instillation to rabbit eyes by HPLC-MS/MS method and also determine the relative contribution of the nasal and the conjunctival mucosae to systemic ofloxacin absorption following topical instillation. The systemic AUC, Cmax, Tmax and Ke for ophthalmic in situ gel and ophthalmic solution after ocular instillation were 202.63±118.85 and 202.25±57.74 ng mL(-1) h, 54.22±28.31 and 48.4±25.97 ng mL(-1), 1.08±0.20 and 1.25±0.88 h, 0.0576±0.0207 and 0.0388±0.0248, respectively. And the values for the ratios of the AUC of anterior chamber of rabbit eye to blood plasma, AUCac/AUCpl, for ofloxacin conventional eye drop and in situ gel were 0.25 and 0.52, respectively. Statistic results showed that there was no significant difference in systemic absorption between the test groups and the reference groups (P>0.05) as both formulations have an AUCsa/AUCpl of 0.35. Therefore, the ophthalmic in situ gel may not decrease the drugs systemic absorption when administered in an equivalent dose as ophthalmic solutions into the rabbit eyes. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Medical physics aspects of ophthalmic brachytherapy

    International Nuclear Information System (INIS)

    Sharma, S.D.; Shanta, A.; Palani Selvam, T.; Tripathi, U.B.; Bhatt, B.C.

    2004-11-01

    Intraocular melanoma is the most common primary malignancy of the eye. Radiation therapy using ophthalmic plaque has proved successful in the management of various ocular lesions. Although a few centres were using 90 Sr/ 90 Y plaques for shallow turtlours some years ago, eye plaque therapy was not a common practice in India. A revived interest in the use of eye plaque therapy and very high cost of imported sources has led to the development and production of 125 I seed sources by the Radiopharmaceuticals Division, BARC. This report presents a brief description on the clinical, dosimetry and radiation safety aspects of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta ray and 125 I gamma ray eye plaque applicators. This report has been divided in five Sections. Section I presents general introduction of ophthalmic brachytherapy including the structure of a human eye, types of ophthalmic plaques and characteristics of radioisotopes commonly used in such applications. A brief review of sources, applicators and dosimetry of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta and 125 I gamma ophthalmic plaques are given in Section II and Section III, respectively. Section IV contains the single seed dosimetry data of BARC OcuProsta 125 I seed as well as dosimetry data of typical eye plaques loaded with BARC OcuProsta 125 I seed. Quality assurance and radiation safety aspects of these eye applicators are described in Section V. A proforma of the application required to be filled in by the user institution for obtaining regulatory consent to start eye plaque therapy has also been appended to this report. (author)

  6. Ophthalmic Drug Dosage Forms: Characterisation and Research Methods

    OpenAIRE

    Baranowski, Przemysław; Karolewicz, Bożena; Gajda, Maciej; Pluta, Janusz

    2014-01-01

    This paper describes hitherto developed drug forms for topical ocular administration, that is, eye drops, ointments, in situ gels, inserts, multicompartment drug delivery systems, and ophthalmic drug forms with bioadhesive properties. Heretofore, many studies have demonstrated that new and more complex ophthalmic drug forms exhibit advantage over traditional ones and are able to increase the bioavailability of the active substance by, among others, reducing the susceptibility of drug forms to...

  7. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion.

    Science.gov (United States)

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-12-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed cerebral angiography of 7 patients (4 hyaluronic acid [HA] and 3 autologous fat-injected cases) showing ophthalmic artery and its branches occlusion after cosmetic facial filler injections, and underwent intra-arterial thrombolysis. On selective ophthalmic artery angiograms, all fat-injected patients showed a large filling defect on the proximal ophthalmic artery, whereas the HA-injected patients showed occlusion of the distal branches of the ophthalmic artery. Three HA-injected patients revealed diminished distal runoff of the internal maxillary and facial arteries, which clinically corresponded with skin necrosis. However, all fat-injected patients and one HA-injected patient who were immediately treated with subcutaneous hyaluronidase injection showed preserved distal runoff of the internal maxillary and facial arteries and mild skin problems. The size difference between injected materials seems to be associated with different angiographic findings. Autologous fat is more prone to obstruct proximal part of ophthalmic artery, whereas HA obstructs distal branches. In addition, hydrophilic and volume-expansion property of HA might exacerbate blood flow on injected area, which is also related to skin necrosis. Intra-arterial thrombolysis has a limited role in reconstituting blood flow or regaining vision in cosmetic facial filler-associated ophthalmic artery occlusions.

  8. ANAESTHESIA FOR OPHTHALMIC SURGICAL PROCEDURES

    African Journals Online (AJOL)

    Objective: To review factors influencing the choice of anaesthesia for ophthalmic surgical procedures. ... as risk associated with general anaesthesia (8) they are more .... Wilson ME, Pandey SK, Thakur J. Paediatric cataract blindness in the ...

  9. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    International Nuclear Information System (INIS)

    Ayaz, Tunahan; Akansel, Gur.; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-01-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia

  10. Polymyxin B and Trimethoprim Ophthalmic

    Science.gov (United States)

    Polymyxin B and trimethoprim ophthalmic combination is used to treat bacterial infections of the eye including conjunctivitis (pinkeye; infection ... inside and outer parts of the eyelid). Polymyxin B and trimethoprim are in a class of medications ...

  11. Ophthalmic regional blocks: management, challenges, and solutions

    Directory of Open Access Journals (Sweden)

    Palte HD

    2015-08-01

    Full Text Available Howard D Palte Department of Anesthesiology, Perioperative Medicine and Pain Management, Miller School of Medicine, University of Miami, Miami, FL, USA Abstract: In the past decade ophthalmic anesthesia has witnessed a major transformation. The sun has set on the landscape of ophthalmic procedures performed under general anesthesia at in-hospital settings. In its place a new dawn has ushered in the panorama of eye surgeries conducted under regional and topical anesthesia at specialty eye care centers. The impact of the burgeoning geriatric population is that an increasing number of elderly patients will present for eye surgery. In order to accommodate increased patient volumes and simultaneously satisfy administrative initiatives directed at economic frugality, administrators will seek assistance from anesthesia providers in adopting measures that enhance operating room efficiency. The performance of eye blocks in a holding suite meets many of these objectives. Unfortunately, most practicing anesthesiologists resist performing ophthalmic regional blocks because they lack formal training. In future, anesthesiologists will need to block eyes and manage common medical conditions because economic pressures will eliminate routine preoperative testing. This review addresses a variety of topical issues in ophthalmic anesthesia with special emphasis on cannula and needle-based blocks and the new-generation antithrombotic agents. In a constantly evolving arena, the sub-Tenon’s block has gained popularity while the deep angulated intraconal (retrobulbar block has been largely superseded by the shallower extraconal (peribulbar approach. Improvements in surgical technique have also impacted anesthetic practice. For example, phacoemulsification techniques facilitate the conduct of cataract surgery under topical anesthesia, and suture-free vitrectomy ports may cause venous air embolism during air/fluid exchange. Hyaluronidase is a useful adjuvant because it

  12. 21 CFR 524.1484e - Neomycin sulfate and polymyxin B sulfate ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... ophthalmic solution. 524.1484e Section 524.1484e Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1484e Neomycin sulfate and polymyxin B sulfate ophthalmic solution. (a...

  13. Neuro-ophthalmic and clinical characteristics of brain tumours in a ...

    African Journals Online (AJOL)

    Background: Anecdotally, increasing number of patients are seen at Korle Bu Teaching Hospital (KBTH) with brain tumour. Neuro-ophthalmic symptoms and signs may help in timely diagnosis and intervention. Objective: To evaluate the neuro-ophthalmic and clinical characteristics of brain tumour in patients presenting at a ...

  14. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    Energy Technology Data Exchange (ETDEWEB)

    Ayaz, Tunahan; Akansel, Gur. E-mail: gakansel@superonline.com; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-06-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia.

  15. Ophthalmic patients' utilization of technology and social media: an assessment to improve quality of care.

    Science.gov (United States)

    Aleo, Chelsea L; Hark, Lisa; Leiby, Benjamin; Dai, Yang; Murchison, Ann P; Martinez, Patricia; Haller, Julia A

    2014-10-01

    E-health tools have the potential to improve the quality of care for ophthalmic patients, many of whom have chronic conditions. However, little research has assessed ophthalmic patients' use or acceptance of technological devices and social media platforms for health-related purposes. The present study evaluated utilization of technological devices and social media platforms by eye clinic patients, as well as their willingness to receive health reminders through these technologies. A 31-item paper questionnaire was administered to eye clinic patients (n=843) at an urban, tertiary-care center. Questions focused on technology ownership, comfort levels, frequency of use, and preferences for receiving health reminders. Demographic data were also recorded. Eye clinic patients most commonly owned cellular phones (90%), landline phones (81%), and computers (80%). Overall, eye clinic patients preferred to receive health reminders through phone calls and e-mail and used these technologies frequently and with a high level of comfort. Less than 3% of patients preferred using social networking to receive health reminders. In addition, age was significantly associated with technology ownership, comfort level, and frequency of use (ptechnologies more frequently and with a higher comfort level (ptechnologies for appointment reminders, general eye and vision health information, asking urgent medical questions, and requesting prescription refills. Future controlled trials could further explore the efficacy of e-health tools for these purposes.

  16. The assessment of visually impaired persons working capacities using electrophysiological and ophthalmic ergonomics methods

    Directory of Open Access Journals (Sweden)

    M. I. Razumovsky

    2014-07-01

    Full Text Available Aim was to analyze working capacities of visually impaired persons by means of complex electrophysiological and ophthalmic ergonomics eye examination.Materials and methods. Standard clinical ophthalmologic examination (visual acuity measurement, refractometry, biomicroscopy, ophthalmoscopy as well as electrophysiological (electrooculography, electrical sensitivity of the eye, critical flicker fusion frequency and ophthalmic ergonomics tests (accommodation measurement, professional testing using automated system «Proftest-1» were performed.Results. Complex electrophysiological and ophthalmic ergonomics tests were performed in 20 visually impaired persons. Their results revealed direct correlation between electrophysiological and ophthalmic ergonomics indices.Conclusion. Working capacities of visually impaired persons can be assessed reliably using complex electrophysiological and ophthalmic ergonomics eye examination only.

  17. The assessment of visually impaired persons working capacities using electrophysiological and ophthalmic ergonomics methods

    Directory of Open Access Journals (Sweden)

    M. I. Razumovsky

    2014-01-01

    Full Text Available Aim was to analyze working capacities of visually impaired persons by means of complex electrophysiological and ophthalmic ergonomics eye examination.Materials and methods. Standard clinical ophthalmologic examination (visual acuity measurement, refractometry, biomicroscopy, ophthalmoscopy as well as electrophysiological (electrooculography, electrical sensitivity of the eye, critical flicker fusion frequency and ophthalmic ergonomics tests (accommodation measurement, professional testing using automated system «Proftest-1» were performed.Results. Complex electrophysiological and ophthalmic ergonomics tests were performed in 20 visually impaired persons. Their results revealed direct correlation between electrophysiological and ophthalmic ergonomics indices.Conclusion. Working capacities of visually impaired persons can be assessed reliably using complex electrophysiological and ophthalmic ergonomics eye examination only.

  18. Ophthalmic Drug Dosage Forms: Characterisation and Research Methods

    Directory of Open Access Journals (Sweden)

    Przemysław Baranowski

    2014-01-01

    Full Text Available This paper describes hitherto developed drug forms for topical ocular administration, that is, eye drops, ointments, in situ gels, inserts, multicompartment drug delivery systems, and ophthalmic drug forms with bioadhesive properties. Heretofore, many studies have demonstrated that new and more complex ophthalmic drug forms exhibit advantage over traditional ones and are able to increase the bioavailability of the active substance by, among others, reducing the susceptibility of drug forms to defense mechanisms of the human eye, extending contact time of drug with the cornea, increasing the penetration through the complex anatomical structure of the eye, and providing controlled release of drugs into the eye tissues, which allows reducing the drug application frequency. The rest of the paper describes recommended in vitro and in vivo studies to be performed for various ophthalmic drugs forms in order to assess whether the form is acceptable from the perspective of desired properties and patient’s compliance.

  19. Challenges Encountered Using Ophthalmic Anesthetics in Space Medicine

    Science.gov (United States)

    Bayuse, T.; Law, J.; Alexander, D.; Moynihan, S.; LeBlanc, C.; Langford, K.; Magalhaes, L.

    2015-01-01

    On orbit, ophthalmic anesthetics are used for tonometry and off-nominal corneal examinations. Proparacaine has been flown traditionally. However, the manufacturers recently changed its storage requirements from room temperature storage to refrigerated storage to preserve stability and prolong the shelf-life. Since refrigeration on orbit is not readily available and there were stability concerns about flying proparacaine unrefrigerated, tetracaine was selected as an alternative ophthalmic anesthetic in 2013. We will discuss the challenges encountered flying and using these anesthetics on the International Space Station.

  20. Safety comparison of additives in antiglaucoma prostaglandin (PG analog ophthalmic formulations

    Directory of Open Access Journals (Sweden)

    Fukuda M

    2013-03-01

    , HCO-40, and P-80 were thought to be involved in corneal injuries caused by each ophthalmic solution. Corneal injuries due to surface action were observed when using HCO-40 and P-80. When HCO-40 was combined with BAK, it induced micellar BAK and reduced corneal injuries by BAK.Keywords: corneal resistance measuring device, additives, prostaglandin analogs, surface-active agents, corneal epithelial injury

  1. The international council of ophthalmology: vision for ophthalmic education in an interdependent world.

    Science.gov (United States)

    Lee, Andrew G; Golnik, Karl C; Tso, Mark O M; Spivey, Bruce; Miller, Kathleen; Gauthier, Tina-Marie

    2012-10-01

    To describe the emerging strategic global perspective of the International Council of Ophthalmology (ICO) efforts in ophthalmic education. A global perspective describing how the development of sophisticated educational tools in tandem with information technology can revolutionize ophthalmic education worldwide. Review of ICO educational tools, resources, and programs that are available to ophthalmic educators across the globe. With the explosive growth of the Internet, the ability to access medical information in the most isolated of locations is now possible. Through specific ICO initiatives, including the ICO curricula, the "Teaching the Teachers" program, and the launching of the new ICO Center for Ophthalmic Educators, the ICO is providing ophthalmic educators across the globe with access to standardized but customizable educational programs and tools to better train ophthalmologists and allied eye care professionals throughout the world. Access to educational tools and strengthening of global learning will help providers meet the goals of VISION 2020 and beyond in eliminating avoidable blindness. It is the intent of the ICO that its programs for ophthalmic educators, including conferences, courses, curricula, and online resources, result in better-trained ophthalmologists and eye care professionals worldwide. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion

    OpenAIRE

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-01-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed...

  3. Risk factors of ophthalmic disorders in children with developmental delay

    DEFF Research Database (Denmark)

    Sandfeld, L.N.; Jensen, H.; Skov, L.

    2008-01-01

    PURPOSE: To identify diagnoses that increase the risk of ophthalmic disorders in developmentally delayed children. METHODS: A cross-sectional study of 1126 Danish children with developmental delay (IQ Udgivelsesdato: 2008/12......PURPOSE: To identify diagnoses that increase the risk of ophthalmic disorders in developmentally delayed children. METHODS: A cross-sectional study of 1126 Danish children with developmental delay (IQ Udgivelsesdato: 2008/12...

  4. 21 CFR 524.1662 - Oxytetracycline hydrochloride ophthalmic and topical dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride ophthalmic and topical dosage forms. 524.1662 Section 524.1662 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... DOSAGE FORM NEW ANIMAL DRUGS § 524.1662 Oxytetracycline hydrochloride ophthalmic and topical dosage forms. ...

  5. International Council of Ophthalmology: Refocusing Ophthalmic Education in the Asia-Pacific Region and Beyond.

    Science.gov (United States)

    Golnik, Karl; Mayorga, Eduardo; Spivey, Bruce; Ritch, Robert; Gauthier, Tina-Marie

    2012-01-01

    The International Council of Ophthalmology (ICO) is a global organization with a regional focus. Working in partnership with supranational and ICO member societies, the ICO is building a "World Alliance for Sight" to improve access to the highest-quality eye care worldwide. Designed to preserve and restore vision on an international scale, the ICO initiative, "Refocusing Ophthalmic Education," enhances ophthalmic education of residents, subspecialists, medical students, and allied eye care personnel by redefining the most effective ways to teach and in creating beneficial educational opportunities. The "Teaching the Teachers" program helps ophthalmic educators incorporate more effective methods of training and continuing professional development to meet societal needs, achieved in part through regional courses for residency program directors; symposia, and keynote talks presented by ICO's World Ophthalmology Educational Colloquium, Conferences for Ophthalmic Educators, and ophthalmic surgical competency rubrics. Recognizing that standardized curricula are essential for consistent ophthalmic education, the ICO has developed a curricular framework whereby goals, expectations, knowledge base, competencies, and technical training are delineated. The ICO is defining worldwide models of team training and compiling best practice, which will include training-program accreditation to ensure improvement in the education of ophthalmologists. International Council of Ophthalmology Web-based teaching courses, a Webinar Network, and a technology blog further support information and communication technologies for teaching and learning. At the ICO's Center for Ophthalmic Educators (educators.icoph.org), trainers will find valuable teaching resources in multiple languages as well as ways to share ideas and collaborate with peers and other ophthalmic educators.

  6. Determination of permeability coefficients of ophthalmic drugs through different layers of porcine, rabbit and bovine eyes

    OpenAIRE

    Nagel, Stefan; Guthoff, Rudolf F.; Weitschies, Werner; Seidlitz, Anne; Kristl, Albin; Žakelj, Simon; Loch, Christian

    2015-01-01

    To treat ophthalmic diseases like glaucoma or inflammatory disorders topically applied ophthalmic formulations such as eye drops are usually used. In addition, novel ophthalmic implants releasing drug substances locally into different parts of the eye are available today. In the work presented here, the permeability coefficients of selected drugs (ciprofloxacin hydrochloride, lidocaine hydrochloride, timolol maleate) for ophthalmic tissues were determined using side-by-side diffusion chambers...

  7. Comparison of Drug Concentrations in Human Aqueous Humor after the Administration of 0.3% Gatifloxacin Ophthalmic Gel, 0.3% Gatifloxacin and 0.5% Levofloxacin Ophthalmic Solutions.

    Science.gov (United States)

    Ding, Wenting; Ni, Weiling; Chen, Huilian; Yuan, Jingqun; Huang, Xiaodan; Zhang, Zheng; Wang, Yao; Yu, Yibo; Yao, Ke

    2015-01-01

    To investigate the penetration of 0.3% gatifloxacin ophthalmic gel, 0.3% gatifloxacin ophthalmic solution and 0.5% levofloxacin ophthalmic solution into aqueous humor after topical application. Age-related cataract patients (150 eyes in 150 cases) receiving phacoemulsification were randomly divided into three groups: a 0.3% gatifloxacin gel group (n=50), a 0.3% gatifloxacin solution group (n=50), and a 0.5% levofloxacin solution group (n=50). Each group was administered one drop of gel or solution every 15 minutes for four doses. Aqueous samples were collected at different time points after the last drop. High pressure liquid chromatography (HPLC) was applied to determine the concentrations. The one-way ANOVA analysis was performed. Our data indicated that the concentration of the gatifloxacin gel group was higher than that of the gatifloxacin solution group at all time points (P solution group at 120.0 min and 180.0 min (Psolutions reached their peak values at 60.0 min. 0.3% gatifloxacin ophthalmic gel application produced highest aqueous humor drug concentration, maintained the longest time, had the best penetration and bioavailability.

  8. 78 FR 27971 - Determination That REV-EYES (Dapiprazole Hydrochloride Ophthalmic Solution), 0.5%, Was Not...

    Science.gov (United States)

    2013-05-13

    ...] Determination That REV-EYES (Dapiprazole Hydrochloride Ophthalmic Solution), 0.5%, Was Not Withdrawn From Sale... ophthalmic solution), 0.5%, was not withdrawn from sale for reasons of safety or effectiveness. This... ophthalmic solution, 0.5%, if all other legal and regulatory requirements are met. FOR FURTHER INFORMATION...

  9. A New Acute Attack of Angle Closure Glaucoma Animal Model with Healon 5

    Directory of Open Access Journals (Sweden)

    Silvania Y. F. Lau

    2011-05-01

    Full Text Available Acute angle closure glaucoma (AACG is an ocular emergency and sight -threatening disease in which the intraocular ocular pressure (IOP rises suddenly due to blockage of aqueous humor outflow. It can cause permanent loss in visual acuity and visual field. In animal study, the well-established model to study AACG is by fluid infusion and by adjusting the bottle level, a high IOP can be induced in a few seconds. However, there is no blockage of aqueous outflow and the pressure rise is unrealistically fast. To mimic human AACG, we suggest to use Healon 5, an ophthalmic viscosurgical device, which is injected intracamerally to block the aqueous outflow. The IOP is allowed to build up naturally. We found that, with this technique, the IOP elevated at a rate of 0.57 mmHg/min before it hit 40 mmHg, which is considered as AACG in human. The maximum IOP registered was above 70 mmHg. Thinning of retinal nerve fiber layer (RNFL and neural cells lost were seen. Visual function evaluated by ERG showed reduction in a-wave, b-wave, photopic negative response (PhNR and oscillatory potentials (OPs activities. In conclusion, Healon 5 is effective in inducing acute transient rise in IOP which mimics human AACG.

  10. In vitro testing of thiolated poly(aspartic acid) from ophthalmic formulation aspects.

    Science.gov (United States)

    Budai-Szű Cs, Mária; Horvát, Gabriella; Gyarmati, Benjámin; Szilágyi, Barnabás Áron; Szilágyi, András; Csihi, Tímea; Berkó, Szilvia; Szabó-Révész, Piroska; Mori, Michela; Sandri, Giuseppina; Bonferoni, Maria Cristina; Caramella, Carla; Csányi, Erzsébet

    2016-08-01

    Ocular drug delivery formulations must meet anatomical, biopharmaceutical, patient-driven and regulatory requirements. Mucoadhesive polymers can serve as a better alternative to currently available ophthalmic formulations by providing improved bioavailability. If all requirements are addressed, a polymeric formulation resembling the tear film of the eye might be the best solution. The optimum formulation must not have high osmotic activity, should provide appropriate surface tension, pH and refractive index, must be non-toxic and should be transparent and mucoadhesive. We would like to highlight the importance of in vitro polymer testing from a pharmaceutical aspect. We, therefore, carried out physical-chemical investigations to verify the suitability of certain systems for ophthalmic formulations. In this work, in situ gelling, mucoadhesive thiolated poly(aspartic acid)s were tested from ophthalmic formulation aspects. The results of preformulation measurements indicate that these polymers can be used as potential carriers in ophthalmic drug delivery.

  11. Impact of digital imaging and communications in medicine workflow on the integration of patient demographics and ophthalmic test data.

    Science.gov (United States)

    Pandit, Ravi R; Boland, Michael V

    2015-02-01

    To determine the impact of a Digital Imaging and Communications in Medicine (DICOM) workflow on the linkage of demographic information to ophthalmic testing data. Evaluation of technology. Six hundred ninety-nine visual field testing encounters performed by 6 ophthalmic technicians and the transfer error queue of 37 442 ophthalmic test results. At 3 months before and 6 and 18 months after implementation of a DICOM workflow, technicians recorded the work required to enter, confirm, or edit patient demographics in each visual field device. We also determined the proportion of imaging tests sent to an error queue for manual reconciliation because of incorrect demographic information before and 3, 6, and 18 months after the DICOM workflow was established. The proportion of testing encounters for which staff had to enter, edit, or merge patient demographics and the proportion of misfiled images. Staff entered, edited, or merged data for 48% of patients before implementation (n = 237). This decreased to 24% within 6 months and 20% within 18 months of implementing the DICOM archive (n = 230 and n = 232, respectively). Staff could locate a patient in a DICOM work list for 97% of encounters at 3 months and 99% at 18 months. Before implementation, 9.2% of the images required additional intervention to be associated with the correct patient (n = 3581). This decreased by 85% over 6 months to 1.4% (n = 9979; P workflow in an ophthalmology clinic reduced the need to enter or edit patient demographic information into imaging or testing devices by more than 50% and reduced the need to manage misfiled images by 76%. In a clinical environment that demands both efficiency and patient safety, the DICOM workflow is an important update to current practice. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  12. Comparison of the effectiveness of contemporary ophthalmic lenses against β radiation

    International Nuclear Information System (INIS)

    Dunlap, J.H.; Harvey, P.W.; Schwing, R.L.

    1977-01-01

    As part of a study intended to identify the lens material and type that provides maximum eye protection against beta radiation, the effectiveness of contemporary ophthalmic lenses has been evaluated. From the calculations and measurements presented it is evident that safety glasses with crown glass ophthalmic lenses afford the eye the greatest protection against beta radiation, whereas street glasses with plastic ophthalmic lenses afford the eye very little protection. It is to be noted that glass street lenses (approximately 2.2 mm thick) provide greater protection than plastic safety lenses (approximately 3.5 mm thick). A warning is given against the use of safety lenses containing a large percentage of thorium. (U.K.)

  13. 76 FR 71044 - Determination That TRAVATAN (Travoprost Ophthalmic Solution), 0.004%, Was Not Withdrawn From Sale...

    Science.gov (United States)

    2011-11-16

    ...] Determination That TRAVATAN (Travoprost Ophthalmic Solution), 0.004%, Was Not Withdrawn From Sale for Reasons of... Drug Administration (FDA) has determined that TRAVATAN (travoprost ophthalmic solution), 0.004%, was... approve abbreviated new drug applications (ANDAs) for travoprost ophthalmic solution, 0.004%, if all other...

  14. Ophthalmic variables in rehabilitated juvenile Kemp's ridley sea turtles (Lepidochelys kempii).

    Science.gov (United States)

    Gornik, Kara R; Pirie, Christopher G; Marrion, Ruth M; Wocial, Julika N; Innis, Charles J

    2016-03-15

    To determine central corneal thickness (total corneal thickness [TCT], epithelial thickness [ET], and stromal thickness [ST]), anterior chamber depth (ACD), and intraocular pressure (IOP) in Kemp's ridley sea turtles (Lepidochelys kempii). Prospective cross-sectional study. 25 healthy rehabilitated juvenile Kemp's ridley sea turtles. PROCEDURES; Body weight and straight-line standard carapace length (SCL) were recorded. All turtles underwent a complete anterior segment ophthalmic examination. Central TCT, ET, ST, and ACD were determined by use of a spectral-domain optical coherence tomography device. Intraocular pressure was determined with a rebound tonometer; the horse setting was used to measure IOP in all 25 turtles, and the undefined setting was also used to measure IOP in 20 turtles. For each variable, 3 measurements were obtained bilaterally. The mean was calculated for each eye and used for analysis purposes. The mean ± SD body weight and SCL were 3.85 ± 1.05 kg (8.47 ± 2.31 lb) and 29 ± 3 cm, respectively. The mean ± SD TCT, ET, ST, and ACD were 288 ± 23 μm, 100 ± 6 μm, 190 ± 19 μm, and 581 ± 128 μm, respectively. Mean ± SD IOP was 6.5 ± 1.0 mm Hg when measured with the horse setting and 3.8 ± 1.1 mm Hg when measured with the undefined setting. Results provided preliminary reference ranges for objective assessment of ophthalmic variables in healthy juvenile Kemp's ridley sea turtles.

  15. Subhyaloid Hemorrhage in a Case of Devic's Disease | Chakraborti ...

    African Journals Online (AJOL)

    We diagnosed the case as neuromyelitis optica (NMO) based on the examination and investigation findings. NMO or Devic's syndrome is an uncommon clinical syndrome associating unilateral or bilateral optic neuritis and transverse myelitis. Subhyaloid hemorrhage, as an ophthalmic feature of NMO, has not been reported ...

  16. Development and Evaluation of Diclofenac Sodium Loaded-N-Trimethyl Chitosan Nanoparticles for Ophthalmic Use.

    Science.gov (United States)

    Asasutjarit, Rathapon; Theerachayanan, Thitaree; Kewsuwan, Prartana; Veeranodha, Sukitaya; Fuongfuchat, Asira; Ritthidej, Garnpimol C

    2015-10-01

    The ophthalmic preparation of diclofenac sodium (DC) for relieving ocular inflammation is presently available in the market only as an eye drop solution. Due to its low occular bioavailability, it requires frequent application leading to low patients' compliance and quality of life. This study was conducted to develop formulations of DC loaded-N-trimethyl chitosan nanoparticles (DC-TMCNs) for ophthalmic use to improve ocular biavailabiltiy of DC. DC-TMCNs varied in formulation compositions were prepared using ionic gelation technique and evaluated for their physicochemical properties, drug release, eye irritation potential, and ophthalmic absorption of diclofenac sodium. N-Trimethyl chitosan (TMC) with a 49.8% degree of quaternization was synthesized and used for DC-TMCNs production. The obtained DC-TMCNs had particle size in a range of 130-190 nm with zeta potential values of +4 to +9 mV and drug entrapment efficiencies of more than 70% depending on the content of TMC and sodium tripolyphosphate (TPP). The optimized DC-TMCNs formulation contained TMC, DC, and TPP at a weight ratio of TMC/DC/TPP = 3:1:1. Their lyophilized product reconstituted with phosphate buffer solution pH 5.5 possessed a drug release pattern that fitted within the zero-order model. The eye irritation tests showed that DC-TMCNs were safe for ophthalmic use. The in vivo ophthalmic drug absorption study performed on rabbits indicated that DC-TMCNs could improve ophthalmic bioavailability of DC. Results of this study suggested that DC-TMCNs had potential for use as an alternative to conventional DC eye drops for ophthalmic inflammation treatment.

  17. A Profile of Neuro-Ophthalmic Practice Around the World.

    Science.gov (United States)

    Frohman, Larry P

    2018-03-01

    To compare contrast neuro-ophthalmic practice in various countries, an 18-question survey was sent to the international North American Neuro-Ophthalmology Society (NANOS) members in the spring of 2016. At least 1 NANOS member was contacted for each non-US nation in the NANOS membership roster. If there were multiple NANOS members from 1 country, multiple were contacted. If responses were received from more than 1 person from a single country, the first response received was used as the source data. The survey (in English) was emailed to 47 NANOS members from 31 countries. Twenty responses were received representing members from 15 nations. In all 15 nations, at least half of the neuro-ophthalmologists were trained as ophthalmologists. In 60% of nations, at least half of the neuro-ophthalmologists were trained internally, whereas in 33% of countries, at least half were trained in the United States. The number of physicians who practiced a significant amount of neuro-ophthalmology ranged from low (0.08/million, India) to high (3.10/million, Israel). Countries having the highest percentage of neuro-ophthalmologists exclusively practicing neuro-ophthalmology also were those with better patient access to neuro-ophthalmic care. Requirement of approval to see a neuro-ophthalmologist or for imaging studies requested by neuro-ophthalmologists was not typical. In most nations, academic neuro-ophthalmologists were paid a straight salary. In no nation were neuro-ophthalmologists paid more than another ophthalmic subspecialty. Individual national health care system designs and compensation models have had a profound influence on the rewards and challenges that face neuro-ophthalmologists. There seems to have been a connection between recognition of the discipline, financial rewards of neuro-ophthalmic practice, conditions that permit full-time neuro-ophthalmic practice, and patient access to care. A higher percentage of gross national product for health care did not seem to

  18. IN-SITU OPHTHALMIC GELS FOR THE TREATMENT OF EYE DISEASES

    OpenAIRE

    M. Jothi, S.L. Harikumar* and Geeta Aggarwal

    2012-01-01

    Topical administration of a drug in the conjunctival cul-de-sac is the treatment of choice for diseases of the anterior segment of eye. Development of ophthalmic drug delivery systems has always been challenging because of the drawbacks with this route, like non-productive absorption, drainage, induced lacrimation, tear turn over, impermeability of drugs to cornea. New approaches have been investigated for delivery of drugs to the eye by means of polymeric delivery of ophthalmic drugs to the ...

  19. Location of the internal carotid artery and ophthalmic artery segments for non-invasive intracranial pressure measurement by multi-depth TCD.

    Science.gov (United States)

    Hamarat, Yasin; Deimantavicius, Mantas; Kalvaitis, Evaldas; Siaudvytyte, Lina; Januleviciene, Ingrida; Zakelis, Rolandas; Bartusis, Laimonas

    2017-12-01

    The aim of the present study was to locate the ophthalmic artery by using the edge of the internal carotid artery (ICA) as the reference depth to perform a reliable non-invasive intracranial pressure measurement via a multi-depth transcranial Doppler device and to then determine the positions and angles of an ultrasonic transducer (UT) on the closed eyelid in the case of located segments. High tension glaucoma (HTG) patients and healthy volunteers (HVs) undergoing non-invasive intracranial pressure measurement were selected for this prospective study. The depth of the edge of the ICA was identified, followed by a selection of the depths of the IOA and EOA segments. The positions and angles of the UT on the closed eyelid were measured. The mean depth of the identified ICA edge for HTG patients was 64.3 mm and was 63.0 mm for HVs (p = 0.21). The mean depth of the selected IOA segment for HTG patients was 59.2 mm and 59.3 mm for HVs (p = 0.91). The mean depth of the selected EOA segment for HTG patients was 48.5 mm and 49.8 mm for HVs (p = 0.14). The difference in the located depths of the segments between groups was not statistically significant. The results showed a significant difference in the measured UT angles in the case of the identified edge of the ICA and selected ophthalmic artery segments (p = 0.0002). We demonstrated that locating the IOA and EOA segments can be achieved using the edge of the ICA as a reference point. OA: ophthalmic artery; IOA: intracranial segments of the ophthalmic artery; EOA: extracranial segments of the ophthalmic artery; ICA: internal carotid artery; UT: ultrasonic transducer; HTG: high tension glaucoma; SD: standard deviation; ICP: intracranial pressure; TCD: transcranial Doppler.

  20. Electronic compliance monitoring of topical treatment after ophthalmic surgery.

    Science.gov (United States)

    Hermann, Manuel Marcel; Ustündag, Can; Diestelhorst, Michael

    2010-08-01

    The success of many medical treatments is built on compliance. Electronic monitoring is the most accurate tool to quantify compliance by measuring adherence. In order to assess the efficiency of a recently introduced miniature monitoring device for eye drop application, we evaluated adherence in ophthalmic patients undergoing post-operative short-term topical treatment. This pilot study enrolled 30 outpatients (mean age 61.8 +/- 18.5 years) after cataract (n = 24) and glaucoma filtration surgery (n = 6) applying fixed-combination eye drops containing prednisolone and gentamicin five times daily for 2 weeks. Patients received eye drops in conventional bottles each equipped with a miniature monitoring device recording events of application. Two patients failed to bring back the monitoring device; therefore data collected from only 28 patients could be examined. Data showed highly variable results with a mean dose compliance of 50.2%. Dose compliance was below 25% in approximately one out of five patients. Four cataract patients, but no glaucoma patient, discontinued therapy prematurely. The observed mean dosage interval was calculated for each patient and ranged 4.6-19.7 h. Thirty percent of analysed dosage intervals exceeded 12.0 h. Different patterns of compliance behaviour-like early non-persistence, drug holiday and low treatment frequency could be identified and illustrated using electronic data. Age or gender did not significantly influence compliance rates. Our pilot study demonstrates successful electronic compliance monitoring using a technology capable of continuous data recording over weeks of treatment. The low compliance rate for a relevant part of the patients demonstrates the necessity to study and improve compliance in ophthalmology. In future, new application methods and electronic application devices may improve treatment response in eye care.

  1. Modified Descemet’s Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries

    Directory of Open Access Journals (Sweden)

    Itaru Oyakawa

    2018-01-01

    Full Text Available Purpose. Descemet’s stripping automated endothelial keratoplasty (DSAEK is more difficult in hypotonic eyes with filtering bleb, due to the difficulties in elevating the intraocular pressure (IOP. We report a new method that uses ophthalmic viscoelastic devices (OVDs to achieve good graft adhesion. Case Presentation. We performed modified DSAEK surgery on 2 eyes of 2 patients, who had previously undergone a trabeculectomy. Both eyes had functioning filtering blebs; the IOP was lower than 10 mmHg without medication. After the graft was inserted into the anterior chamber, the conjunctiva was penetrated, apart from the bleb, using a 30 G needle, and Healon V® was injected into the bleb until the encapsulated space was filled completely. Air was subsequently injected into the anterior chamber to promote the graft attachment to the back surface of the cornea. The IOP was elevated above 40 mmHg in both eyes 1 h after surgery and then decreased to less than 30 mmHg over the subsequent 3 h period. The implanted graft showed good adhesion and no dislocation. Conclusions. Our novel DSAEK procedure that adds one step of OVD injection into the filtering bleb may be useful for hypotonic eyes that had undergone filtering surgeries.

  2. Efficacy of bromfenac sodium ophthalmic solution for treatment of dry eye disease.

    Science.gov (United States)

    Fujishima, Hiroshi; Fuseya, Miki; Ogata, Masarou; Murat, Dogru

    2015-01-01

    To evaluate the efficacy of bromfenac sodium ophthalmic solution (BF) in patients with dry eye disease (DED) inadequately controlled by monotherapy with artificial tears (ATs). An investigator-oriented trial with a single-arm, nonrandomized, open-label design. Twenty-six patients, who showed no symptomatic improvement of DED after 1 month of AT treatment, were enrolled. Bromfenac sodium ophthalmic solution was administered adjunctively with AT for 1 month. The BF treatment was then discontinued, and AT treatment alone was continued for 3 months. The signs and symptoms were evaluated at the beginning of BF treatment (Pre), at the end of the combined BF and AT treatment (BF1M), and at 1 and 3 months after discontinuation of BF treatment (Po1M and Po3M, respectively). The dryness scores at BF1M were significantly improved compared with Pre (P ophthalmic solution has improved the dryness of the eye and signs of DED through its anti-inflammatory effects. Nonsteroidal anti-inflammatory drugs were suitable as anti-inflammatory ophthalmic solutions for patients with DED.

  3. Ophthalmic Drug Delivery Systems for Antibiotherapy—A Review

    Science.gov (United States)

    Dubald, Marion; Bourgeois, Sandrine; Andrieu, Véronique; Fessi, Hatem

    2018-01-01

    The last fifty years, ophthalmic drug delivery research has made much progress, challenging scientists about the advantages and limitations of this drug delivery approach. Topical eye drops are the most commonly used formulation in ocular drug delivery. Despite the good tolerance for patients, this topical administration is only focus on the anterior ocular diseases and had a high precorneal loss of drugs due to the tears production and ocular barriers. Antibiotics are popularly used in solution or in ointment for the ophthalmic route. However, their local bioavailability needs to be improved in order to decrease the frequency of administrations and the side effects and to increase their therapeutic efficiency. For this purpose, sustained release forms for ophthalmic delivery of antibiotics were developed. This review briefly describes the ocular administration with the ocular barriers and the currently topical forms. It focuses on experimental results to bypass the limitations of ocular antibiotic delivery with new ocular technology as colloidal and in situ gelling systems or with the improvement of existing forms as implants and contact lenses. Nanotechnology is presently a promising drug delivery way to provide protection of antibiotics and improve pathway through ocular barriers and deliver drugs to specific target sites. PMID:29342879

  4. Ophthalmic Drug Delivery Systems for Antibiotherapy—A Review

    Directory of Open Access Journals (Sweden)

    Marion Dubald

    2018-01-01

    Full Text Available The last fifty years, ophthalmic drug delivery research has made much progress, challenging scientists about the advantages and limitations of this drug delivery approach. Topical eye drops are the most commonly used formulation in ocular drug delivery. Despite the good tolerance for patients, this topical administration is only focus on the anterior ocular diseases and had a high precorneal loss of drugs due to the tears production and ocular barriers. Antibiotics are popularly used in solution or in ointment for the ophthalmic route. However, their local bioavailability needs to be improved in order to decrease the frequency of administrations and the side effects and to increase their therapeutic efficiency. For this purpose, sustained release forms for ophthalmic delivery of antibiotics were developed. This review briefly describes the ocular administration with the ocular barriers and the currently topical forms. It focuses on experimental results to bypass the limitations of ocular antibiotic delivery with new ocular technology as colloidal and in situ gelling systems or with the improvement of existing forms as implants and contact lenses. Nanotechnology is presently a promising drug delivery way to provide protection of antibiotics and improve pathway through ocular barriers and deliver drugs to specific target sites.

  5. Subspecialization of the ophthalmic literature: a review of the publishing trends of the top general, clinical ophthalmic journals.

    Science.gov (United States)

    Kumar, Anupma; Cheeseman, Robert; Durnian, Jonathan M

    2011-06-01

    To investigate the publishing trends of the top general clinical ophthalmic journals and to report: (1) the proportions of articles published in terms of ophthalmic subspecialty, (2) the study design used, (3) any changes in publishing trends, and (4) any differences in the quality of study design between the subspecialties. Retrospective, database review. All original articles published in the top general, clinical ophthalmology journals from 2005 through 2009. All general, clinical ophthalmic journals were selected from the top 20 journals based on 2008 impact factor. All abstracts from original articles were reviewed, and the subject matter was recorded as belonging to 1 of the 11 ophthalmic subspecialties. After the content of the article was assigned, then the study design was recorded as one of the following: nonanalytic study, case-control or cohort study, randomized control trial, meta-analysis, laboratory science article, or systemic review. Subspecialty of the article and the study design used. Seven journals were included, and 12 426 abstracts were reviewed. Articles relating to medical retina were the most prevalent (29.1%), and those relating to strabismus were the least prevalent (2.3%). Case-control or cohort studies comprised most study designs (40.1%), with meta-analyses comprising the least (0.3%). The mean number of articles per year was 2485 (standard deviation, 125.1), remaining stable over the study period. Medical retina articles were significantly more common in 2009 than in 2005 (chi-square, 11.2; P = 0.0008), whereas the proportion of oculoplastic articles was significantly reduced (chi-square, 16.9; P<0.0001). Cataract and refractive surgery had the highest proportions of articles using the higher forms of study design (7.8%), and oculoplastics had the highest proportion of nonanalytic studies (64.5%). There are great differences across the specialty of ophthalmology in the subject matter of published literature, probably driven by recent

  6. Ophthalmic Start-Up Chief Executive Officers' Perceptions of Development Hurdles.

    Science.gov (United States)

    Stewart, William C; Nelson, Lindsay A; Kruft, Bonnie; Stewart, Jeanette A

    2018-01-01

    To identify current challenges facing ophthalmic pharmaceutical start-ups in developing new products. Surveys were distributed to the chief executive officer (CEO) or president of ophthalmic start-ups. The survey attracted 24 responses from 78 surveys distributed (31%). The CEOs stated that a lack of financial capital (n = 18, 75%), FDA regulations (n = 6, 25%), and failure to meet clinical endpoints (n = 6, 25%) were their greatest development hurdles. Risk aversion to medicines in early development (n = 18, 75%), mergers and acquisitions reducing corporate choice for licensing agreements (n = 7, 29%), the emergence of large pharmaceutical-based venture capital funding groups (n = 12, 50%), and the failure of many large pharmaceutical companies to develop their own medicines (n = 10, 42%) were noted as recent prominent trends affecting fundraising. The study suggests that development funding, regulatory burden, and meeting clinical endpoints are the greatest development challenges faced by ophthalmic start-up CEOs. © 2017 S. Karger AG, Basel.

  7. Formulation and stability of an extemporaneous 0.02% chlorhexidine digluconate ophthalmic solution

    Directory of Open Access Journals (Sweden)

    Shu-Chiao Lin

    2015-12-01

    Conclusion: The acetate-buffered 0.02% chlorhexidine digluconate ophthalmic solution stored in light-resistant high-density polyethylene eyedroppers demonstrated excellent stability at 2–25°C for 6 months after being sealed and for 1 month after opening. This finding will enable us to prepare 0.02% chlorhexidine digluconate ophthalmic solutions based on a doctor's prescription.

  8. An international strategic plan to preserve and restore vision: four curricula of ophthalmic education.

    Science.gov (United States)

    Tso, Mark O M; Goldberg, Morton F; Lee, Andrew G; Selvarajah, Sivaguru; Parrish, Richard K; Zagorski, Zbigniew

    2007-05-01

    To highlight the four International Curricula of Ophthalmic Education developed by the Task Forces of the International Council of Ophthalmology, published in Klinische Monatsblätter für Augenheilkunde in November 2006. A global perspective of developing educational curricula as tools to improve eye care. Review of the experience and conclusions of the four international panels. The Task Force on Resident and Specialist Education developed a curriculum consisting of 15 topics in basic, standard, and advanced levels to provide flexibility of educational programs of the ophthalmic specialist in different locations across the world. The curricula were designed to be an educational tool to stimulate multiple levels of training of the ophthalmic specialist. The Task Force on Ophthalmic Education of Medical Students designed a curriculum covering 11 topics and provides illustrative materials for teachers and students. The Task Force strongly advocates the ophthalmology curriculum to be part of the core program of general medical schools education. The Task Force on Para-ophthalmic Vision Specialist Education developed a curriculum to highlight the importance of a team approach to eye care, consisting of ophthalmic specialists and paraophthalmic personnel to produce maximum efficiency. The Task Force on Continuing Medical Education (CME) designed a curriculum exploring the principles, elements, categories, and administration of CME activities in a variety of topics. These curricula shifted the traditional apprentice system of education to a curriculum-based training program in which goals, expectations, competencies, and technical training are defined to improve eye care worldwide.

  9. 21 CFR 349.14 - Ophthalmic emollients.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Ophthalmic emollients. 349.14 Section 349.14 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR.... (4) Petrolatum, up to 100 percent. (5) White ointment, up to 100 percent. (6) White petrolatum, up to...

  10. Absorbed doses to the main parts of eyeball due to use 90Sr + 90Y ophthalmic applicator

    International Nuclear Information System (INIS)

    Chen Lishu

    1993-05-01

    The ophthalmic radiotherapy dosimetry and some affecting factors are introduced. The distributions of absorbed doses to the main parts of a fresh eyeball such as the cornea, sclera, lens and anterior chamber, during the radiotherapy by using a 90 Sr + 90 Y ophthalmic applicator are presented. An tissue-equivalent extrapolation ionization chamber was used in the dose measurement. The reasonable doses during ophthalmic radiotherapy for different depths have been obtained. Therefore, the absorbed dose to the lens, the most sensitive organ, can be given. These data are useful for radiation protection in ophthalmic radiotherapy

  11. Effect of textured eye drop bottles on the photostability of pranoprofen 0.1% ophthalmic solution.

    Science.gov (United States)

    Iwatsuka, Kinya; Inada, Katsuhiro; Ueoka, Hiroki; Otsuka, Tadashi; Maeda, Masaki; Yamaguchi, Masazumi; Yasueda, Shin-ichi

    2015-01-01

    Ophthalmic solutions are usually filled in a plastic bottle due to its durability and disposability. In Japan, photostability is one of the concerns for the quality control because an eye drop bottle must be a transparent container. The present work studied the effect of textured eye drop bottles on its light blocking to improve the photostability of ophthalmic solutions. We investigated the photostability of Pranoprofen ophthalmic solution filled in a variety of textured eye drop bottles. Pranoprofen content was analyzed by high-performance liquid chromatography and surface structure of textured eye drop bottles was evaluated by transmittance, calculated average roughness (Ra) and haze intensity. We observed that eye drop bottle which had greater than Ra value of 1.0 µm and haze intensity 62% clearly showed photostability improvement. This report is the first one which shows that photostability of ophthalmic solution is improved by using textured eye drop bottle. Moreover, this approach is a simple and effective method to improve the photostability. This method is available for not only various ophthalmic applications but also other liquid pharmaceuticals or food products.

  12. Dural AVM supplied by the ophthalmic artery.

    LENUS (Irish Health Repository)

    Flynn, T H

    2012-02-03

    Dural arteriovenous malformations in the anterior cranial fossa are rare and are especially prone to haemorrhage. These lesions are usually treated by surgical excision. We report the embolization of an anterior cranial fossa DAVM using an endovascular approach via the ophthalmic artery.

  13. Superior ophthalmic vein enlargement and increased muscle index in dysthyroid optic neuropathy.

    Science.gov (United States)

    Lima, Breno da Rocha; Perry, Julian D

    2013-01-01

    To compare superior ophthalmic vein diameter and extraocular muscle index in patients with thyroid eye disease with or without optic neuropathy. High-resolution CT scan images of 40 orbits of 20 patients with history of thyroid eye disease (with or without optic neuropathy), who underwent orbital decompression surgery from January 2007 to November 2009, were retrospectively reviewed. Superior ophthalmic vein diameter was measured in coronal and axial planes. Extraocular muscle index was calculated according to the method proposed by Barrett et al. The clinical diagnosis of optic neuropathy was based on characteristic signs that included afferent pupillary defect, decreased visual acuity, visual field defects, and dyschromatopsia. Orbits were divided in 2 groups based on presence or absence of optic neuropathy. Superior ophthalmic vein diameter was significantly higher in orbits with concomitant optic neuropathy (mean 2.4 ± 0.4mm, p optic neuropathy (mean 57.9% ± 5.7%, p = 0.0002). Muscle index greater than 50% was present in all patients with dysthyroid optic neuropathy. This study suggests that patients with thyroid eye disease with enlarged superior ophthalmic vein and increased extraocular muscle index are more likely to have concomitant optic neuropathy.

  14. Effects of viscoelastic ophthalmic solutions on cell cultures

    Directory of Open Access Journals (Sweden)

    Madhavan Hajib

    1998-01-01

    Full Text Available The development of mild but significant inflammation probably attributable to viscoelastic ophthalmic solutions in cataract surgery was recently brought to the notice of the authors, and hence a study of the effects of these solutions available in India, on cell cultures was undertaken. We studied the effects of 6 viscoelastic ophthalmic solutions (2 sodium hyaluronate designated as A and B, and 4 hydroxypropylmethylcellulose designated as C, D, E and F on HeLa, Vero and BHK-21 cell lines in tissue culture microtitre plates using undiluted, 1:10 and 1:100 dilutions of the solutions, and in cover slip cultures using undiluted solutions. Phase contrast microscopic examination of the solutions was also done to determine the presence of floating particles. The products D and F produced cytotoxic changes in HeLa cell line and these products also showed the presence of floating particles under phase contrast microscopy. Other products did not have any adverse effects on the cell lines nor did they show floating particles. The viscoelastic ophthalmic pharmaceutical products designated D and F have cytotoxic effects on HeLa cell line which appears to be a useful cell line for testing these products for their toxicity. The presence of particulate materials in products D and F indicates that the methods used for purification of the solution are not effective.

  15. 21 CFR 349.12 - Ophthalmic demulcents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Ophthalmic demulcents. 349.12 Section 349.12 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR....2 to 1 percent. (5) Propylene glycol, 0.2 to 1 percent. (e) Polyvinyl alcohol, 0.1 to 4 percent. (f...

  16. Ophthalmic implications of seasonal affective disorder

    International Nuclear Information System (INIS)

    Paramore, J.E.; King, V.M.

    1989-01-01

    A review of seasonal affective disorder (SAD) is presented with a discussion of its standard treatment of phototherapy. A number of ophthalmic implications related to SAD are proposed. These implications relate to both the condition and the phototherapy used in its treatment, especially the use of full spectrum light which contains ultraviolet and near ultraviolet radiation. 12 references

  17. [Tibolone's effect on retinal and ophthalmic arteries flowmetry].

    Science.gov (United States)

    Souza, Marco Aurélio Martins de; Geber, Selmo

    2008-11-01

    to evaluate the effect of tibolone use on doppler-velocimetric parameters of ophthalmic and retinal arteries. clinical, prospective, longitudinal, randomized, placebo-controlled, triple-blind study, in which among 100 menopausal women, 50 have used 2.5 mg of the active principle tibolone (Tib Group) and 50, placebo as a means to form the control-group (Plac Group). In the Tib Group, 44 of the 50 women returned after 84 days to finish the exams, and in the Plac Group, 47. The ophthalmic and retinal arteries were studied to determine the resistance index (RI), the pulsatility index (PI) and the systole/diastole ratio (S/D). Assessments have been done before and 84 days after medication. The t-Student test has been used for the comparison of means between the groups in independent samples, as well as for within-group comparisons in dependent samples. in both groups, the women's characteristics were similar in age, menopause duration, body mass index, arterial blood pressure, deliveries and cardiac rate. The Tib Group presented the following values in the ophthalmic artery: RI(pre)=0.71+/-0.05, RI(post)0.72+/-0.08 (p=0.43); PI(pre)=1.29+/-0.22, PI(post)=1.30+/-0.25 (p=0.4) and S/D(pre)=3.49+/-0.77, SD(post)=3.65+/-0.94 (p=0.32). In the retinal artery, the following values have been found: RI(pre)=0.67+/-0.09, RI(post)=0.69+/-0.10 (p=0.7); PI(pre)=1.20+/-0.29, PI(post)=1.22+/-0.3 (p=0.2) and SD(pre)=3.29+/-0.95, SD(post)=3.30+/-1.07 (p=0.3). Also, the tibolone and control groups did not show any significant difference in regard to the above indexes in the end of the study. the 2.5 mg dose of tibolone had no effect on the Doppler velocimetry indexes of the ophthalmic and retinal arteries.

  18. [Biological availability of ophthalmic drugs. 1. Increasing drug permeability in the cornea].

    Science.gov (United States)

    Masteiková, R; Chalupová, Z; Savickiene, N

    2004-03-01

    Most eye diseases are treated by topical administration of ophthalmic preparations. Low ophthalmic bioavailability is due to a number of physiological and physicochemical factors. The main obstacle to the penetration of active ingredients to the eye is the layered character of the cornea. Formulation of ophthalmic preparations enabling easier penetration of this biological barrier thus ranks among the most effective ways of improving bioavailability. Penetrability of the cornea can be increased by the following methods: a) adjustment of the actual acidity in such a way that pH of the preparation makes it possible to produce the optimal portion of non-ionized particles; b) incorporation of absorption enhancers (non-ionic tensides, salts of bile acids, some antimicrobial substances, EDTA, cyclodextrins, etc.) into the composition of the preparation, and c) production of prodrugs or ionic pairs.

  19. Access to the ophthalmic artery by retrograde approach through the posterior communicating artery for intra-arterial chemotherapy of retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Chi-Tuan; Blanc, Raphael; Pistocchi, Silvia; Bartolini, Bruno; Piotin, Michel [Fondation Rothschild Hospital, Department of Interventional Neuroradiology, Paris (France); Lumbroso-Le Rouic, Livia [Institut Curie, Department of Ocular Oncology, Paris (France)

    2012-08-15

    Intra-arterial infusion of chemotherapy into the ophthalmic artery for treatment of retinoblastoma has been realized after catheterization of the internal carotid and temporary balloon occlusion beyond the orifice of the ophthalmic artery, or more recently after superselective canulation of the ophthalmic artery by a microcatheter. The superselective catheterization of the ophthalmic artery could be cumbersome because of the implantation of the ostium on the carotid siphon or because of the tortuosity of the carotid siphon. We report our experience of using a retrograde approach through the posterior communicating artery that allows a more direct angle of access to the origin of the ophthalmic artery. (orig.)

  20. Long-term results of treatment with diquafosol ophthalmic solution for aqueous-deficient dry eye.

    Science.gov (United States)

    Koh, Shizuka; Ikeda, Chikako; Takai, Yoshihiro; Watanabe, Hitoshi; Maeda, Naoyuki; Nishida, Kohji

    2013-09-01

    To evaluate the preliminary long-term efficacy of diquafosol ophthalmic solution for aqueous-deficient dry eye. Fifteen patients with mild-to-moderate aqueous-deficient dry eye were enrolled. After a washout period, the patients were treated with 3 % diquafosol ophthalmic solution for 6 months. We assessed 12 subjective dry eye symptoms, corneal and conjunctival staining with fluorescein, tear film break-up time (BUT), lower tear meniscus height measured with anterior-segment optical coherence tomography, Schirmer's testing, and adverse reactions at baseline and 1, 3, and 6 months after the start of treatment. Treatment with diquafosol ophthalmic solution significantly improved dry eye symptoms, corneal staining, BUT, and tear meniscus height at 1 month and maintained the effectiveness for 6 months. Conjunctival staining significantly improved 3 and 6 months after treatment. No significant adverse reactions developed. Prolonged use of diquafosol ophthalmic solution for 6 months produced significant improvement both subjectively (dry eye symptom score) and objectively (ocular staining score and tear function tests) for aqueous-deficient dry eye.

  1. Ophthalmic plastic and orbital surgery in Taiwan.

    Science.gov (United States)

    Hsu, Chi-Hsin; Lin, I-Chan; Shen, Yun-Dun; Hsu, Wen-Ming

    2014-06-01

    We describe in this paper the current status of ophthalmic plastic and orbital surgery in Taiwan. Data were collected from the Bureau of National Health Insurance of Taiwan, the Bulletin of the Taiwan Ophthalmic Plastic and Reconstructive Society, and the Statistics Yearbook of Practicing Physicians and Health Care Organizations in Taiwan by the Taiwan Medical Association. We ascertained that 94 ophthalmologists were oculoplastic surgeons and accounted for 5.8% of 1621 ophthalmologists in Taiwan. They had their fellowship training abroad (most ophthalmologists trained in the United States of America) or in Taiwan. All ophthalmologists were well trained and capable of performing major oculoplastic surgeries. The payment rates by our National Health Insurance for oculoplastic and orbital surgeries are relatively low, compared to Medicare payments in the United States. Ophthalmologists should promote the concept that oculoplastic surgeons specialize in periorbital plastic and aesthetic surgeries. However, general ophthalmologists should receive more educational courses on oculoplastic and cosmetic surgery. Copyright © 2014. Published by Elsevier B.V.

  2. Development and Effects of FTY720 Ophthalmic Solution on Corneal Allograft Survival

    OpenAIRE

    Zhaochuan Liu; Haotian Lin; Chulong Huang; Wan Chen; Wu Xiang; Yu Geng; Weirong Chen

    2015-01-01

    Fingolimod (FTY720), a novel class of sphingosine 1-phosphate receptor modulators, has received special interest among ophthalmologists, particularly given that oral administration of FTY720 has proven to effectively treat corneal graft rejection in animal models. However, no studies have examined the performance of FTY720 as an ophthalmic solution in reducing corneal rejection in high-risk corneal rejection models, and the stability and ocular irritation profile of FTY720 ophthalmic solution...

  3. Ophthalmic examination in early diagnosis of Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Xin Li

    2018-02-01

    Full Text Available Alzheimer's disease is a progressive neurodegenerative disorder causing irreversible deterioration in memory and loss of self-care ability, which is seriously affecting the quality of life. There is no cure for Alzheimer's disease. Medication only can control the progression of the disease. Early diagnosis and control of disease progress is of great significance in improving the quality of life of the patients and reducing the burden of family and society. Ophthalmic examination is seen as a window which can “see” brain directly, and some changes in the eye can reflect the changes of the brain most directly. This paper reviews the ophthalmic examination of Alzheimer's disease, including optical coherence tomography(OCT, visual field, contrast sensitivity and eye movements, et al. We hope to provide a new idea for the early diagnosis of Alzheimer's disease.

  4. Postoperative pain in complex ophthalmic surgical procedures: comparing practice with guidelines.

    Science.gov (United States)

    Lesin, Mladen; Sundov, Zeljka Duplancic; Jukic, Marko; Puljak, Livia

    2014-06-01

    To analyze the management of postoperative pain after complex ophthalmic surgery and to compare it to the guidelines. A retrospective study. University Hospital Split, Croatia. Patients (N = 447) who underwent complex ophthalmic surgical procedures from 2008 to 2012. The following data were extracted from patient medical records: age, gender, type and dosage of premedication, preoperative patient's physical status, type of procedure, duration of procedure-surgical and anesthesia time, type and dosage of anesthesia, the type and dosage of postoperative analgesia for each postoperative day. None of the patients had information about pain intensity in their records. There were 90% patients who did not receive any medication the night before surgery, 54% did not receive any premedication immediately before surgery, 19% did not receive any pain medication after the surgery in the operating room and 46% of patients did not receive any analgesics after being released to the ophthalmology department. Among those who received analgesia after surgery, 98% received only one dose of an analgesic, and 93% of patients received analgesia only on the day of the surgery. Furthermore, patients were returned to the department immediately after surgery, without intensive monitoring. During the analyzed five years there were no educational session organized by anesthesiologist to the ophthalmic surgeons. Postoperative pain management and perioperative care of patients undergoing major ophthalmic surgery indicates lack of attention towards pain intensity and postoperative analgesia. Appropriate interventions should be employed to improve postoperative pain management, to facilitate patient recovery. Wiley Periodicals, Inc.

  5. Comparison of the effects of ophthalmic solutions on human corneal epithelial cells using fluorescent dyes.

    Science.gov (United States)

    Xu, Manlong; Sivak, Jacob G; McCanna, David J

    2013-11-01

    To investigate the effect of differently preserved ophthalmic solutions on the viability and barrier function of human corneal epithelial cells (HCEC) using fluorescent dyes. HCEC monolayers were exposed to the ophthalmic solutions containing benzalkonium chloride (BAK), edetate disodium, polyquad, stabilized oxychloro complex (Purite), sodium perborate, or sorbic acid for 5 min, 15 min, and 1 h. At 24 h after exposure, the cultures were assessed for metabolic activity using alamarBlue. The enzyme activity, membrane integrity, and apoptosis were evaluated using confocal microscopy. Barrier function was assessed using sodium fluorescein. The metabolic assay showed that the BAK-preserved ophthalmic solutions significantly reduced cell viability after a 5-min exposure compared to the phosphate buffered saline treated control (POphthalmic solutions with new preservatives had varying time-dependent adverse effects on cell viability, and the preservative-free solution had the least effect on HCEC. Sodium fluorescein permeability showed that HCEC monolayers treated with BAK-preserved solutions were more permeable to sodium fluorescein than those treated by the other ophthalmic solutions (Psolutions had greater adverse effects on metabolic activity, enzyme activity, membrane integrity, cell viability, and barrier function than the solutions that were not preserved with BAK. Our study suggests that BAK-free especially, preservative-free ophthalmic solutions are safer alternatives to BAK-preserved ones.

  6. Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: the DISCOVER Study RESCAN Results.

    Science.gov (United States)

    Ehlers, Justis P; Goshe, Jeff; Dupps, William J; Kaiser, Peter K; Singh, Rishi P; Gans, Richard; Eisengart, Jonathan; Srivastava, Sunil K

    2015-10-01

    Optical coherence tomography (OCT) has transformed the clinical management of a myriad of ophthalmic conditions. Applying OCT to ophthalmic surgery may have implications for surgical decision making and patient outcomes. To assess the feasibility and effect on surgical decision making of a microscope-integrated intraoperative OCT (iOCT) system. Report highlighting the 1-year results (March 2014-February 2015) of the RESCAN 700 portion of the DISCOVER (Determination of Feasibility of Intraoperative Spectral Domain Microscope Combined/Integrated OCT Visualization During En Face Retinal and Ophthalmic Surgery) study, a single-site, multisurgeon, prospective consecutive case series regarding this investigational device. Participants included patients undergoing ophthalmic surgery. Data on clinical characteristics were collected, and iOCT was performed during surgical milestones, as directed by the operating surgeon. A surgeon questionnaire was issued to each surgeon and was completed after each case to evaluate the role of iOCT during surgery and its particular role in select surgical procedures. Percentage of cases with successful acquisition of iOCT (ie, feasibility). Percentage of cases in which iOCT altered surgical decision making (ie, utility). During year 1 of the DISCOVER study, a total of 227 eyes (91 anterior segment cases and 136 posterior segment cases) underwent imaging with the RESCAN 700 system. Successful imaging (eg, the ability to acquire an OCT image of the tissue of interest) was obtained for 224 of 227 eyes (99% [95% CI, 98%-100%]). During lamellar keratoplasty, the iOCT data provided information that altered the surgeon's decision making in 38% of the cases (eg, complete graft apposition when the surgeon believed there was interface fluid). In membrane peeling procedures, iOCT information was discordant with the surgeon's impression of membrane peel completeness in 19% of cases (eg, lack of residual membrane or presence of occult membrane), thus

  7. Shortcomings of the industrial quality assurance of 106Ru ophthalmic plaques

    International Nuclear Information System (INIS)

    Kaulich, T.W.; Nuesslin, F.; Fluehs, D.; Haug, T.; Bamberg, M.

    2001-01-01

    Background: Beta emitting 106 Ru applicators manufactured by Bebig GmbH (Berlin, Germany) are widely used to treat intraocular tumors. The applicators are fixed to the bulbus and removed after several days. The following therapy relevant defects have been detected by an internal clinical acceptance test: risk of leakage and inconsistent dose-rate specifications by the manufacturer. In the meantime, components of the internal clinical acceptance test have been adopted successfully by the manufacturer of the 106 Ru ophthalmic plaques. Material and Method: 106 Ru ophthalmic plaques were tested with the following internal clinical acceptance tests: visual inspection, surface contamination, leakage, and dose-rate verification. The surface contamination test consists of a wet wipe test at moderate pressure. For the leakage test of the 106 Ru ophthalmic plaques a clinically relevant scenario was developed in which the contact of the applicator with human tissue is simulated. In the course of it the applicator is inserted into Ringer's solution for several days. The certified energy dose-rate statements of the manufacturer are examined with a 1 mm 3 plastic scintillator for consistency. (orig.) [de

  8. Audit of patients' awareness of ophthalmic diagnoses.

    Science.gov (United States)

    Sudesh, S; Downes, S M; McDonnell, P J

    1993-09-01

    Providing information to patients about their medical condition and treatment options is important in medical management. To assess patients' knowledge of their ocular disease, prognosis, and treatment a questionnaire based survey was performed. 219 patients selected by random systematic sampling during six months from patients attending general ophthalmic clinics in Selly Oak Hospital, Birmingham, were questioned and 217 questionnaires were analysed. The findings showed that patients' knowledge of their diagnosis depended on their condition: patients with common conditions such as glaucoma and cataract had a better understanding of their condition, its treatment, and prognosis compared with patients with rarer conditions such as retinal detachment or patients with multiple diagnoses. In all, 152 patients (70%) wanted more information about their condition; 49 (23%) did not (although 12 (25%) had attempted to obtain information); and 16 (7%) were undecided. In view of the few patients with a precise understanding of their ophthalmic diagnosis and prognosis and the majority's wish for access to further information, that access needs improvement and different modes of disseminating the information should be implemented.

  9. Pulsed UV laser technologies for ophthalmic surgery

    International Nuclear Information System (INIS)

    Razhev, A M; Bagayev, S N; Churkin, D S; Kargapol’tsev, E S; Chernykh, V V; Iskakov, I A; Ermakova, O V

    2017-01-01

    The paper provides an overview of the results of multiyear joint researches of team of collaborators of Institute of Laser Physics SB RAS together with NF IRTC “Eye Microsurgery” for the period from 1988 to the present, in which were first proposed and experimentally realized laser medical technologies for correction of refractive errors of known today as LASIK, the treatment of ophthalmic herpes and open-angle glaucoma. It is proposed to carry out operations for the correction of refractive errors the use of UV excimer KrCl laser with a wavelength of 222 nm. The same laser emission is the most suitable for the treatment of ophthalmic herpes, because it has a high clinical effect, combined with many years of absence of recrudescence. A minimally invasive technique of glaucoma operations using excimer XeCl laser (λ=308 nm) is developed. Its wavelength allows perform all stages of glaucoma operations, while the laser head itself has high stability and lifetime, will significantly reduce operating costs, compared with other types of lasers. (paper)

  10. Determination of Mycophenolic acid in the vitreous humor using the HPLC-ESI-MS/MS method: application of intraocular pharmacokinetics study in rabbit eyes with ophthalmic implantable device.

    Science.gov (United States)

    Martins Duarte Byrro, Ricardo; de Oliveira Fulgêncio, Gustavo; Rocha Chellini, Paula; da Silva Cunha, Armando; Pianetti, Gerson Antônio

    2013-10-01

    Mycophenolic acid (MPA) is an immunosuppressive agent widely used in the treatment of solid organ transplant rejection. The success of MPA in the treatment of inflammatory intraocular diseases has been reported in recent literature. The treatment of inflammatory eye diseases in the posterior chamber is a challenge due to the anatomy of the eye, which presents certain barriers to drug access. Thus, the bioavailability of drugs in the eye is quite low, and successful drug delivery may well represent a key limiting factor to attaining a successful therapeutic strategy. Ophthalmic controlled drug delivery offers the potential to enhance the efficacy of treatment for pathological conditions. Thus, a novel delivery system based on a biodegradable polymeric device, which can be implanted inside the eye and deliver MPA directly to the target, is being developed. Specific analytical methods to determine the use of effective drugs within the eye are needed to characterize this device. A liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method for the quantitation of MPA in the vitreous humor of rabbits was developed and validated. The vitreous was collected from rabbits, extracted by a protein precipitation extraction procedure and then separated on a C18 column with a mobile phase comprised of 0.15% aqueous acetic acid and methanol (60:40, v/v). The calibration curve was constructed within the range of 3-10,000 ng/mL for MPA. The mean R.S.D. values for the intra-run and inter-run precision were 5.15% and 4.35%. The mean accuracy value was 100.16%. The validated method was successfully applied to determine the MPA concentration in the vitreous humor of rabbits treated with an ocular implantable device. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Pediatric ophthalmic indications for examination under anesthesia in ...

    African Journals Online (AJOL)

    Objective: To determine the ophthalmic indications and challenges for pediatric ocular examination under anesthesia (EUA). Methods: The surgical register and patients' records of children who underwent EUA between 1990 and 2007 were examined to document patients' bio data, diagnoses and details of procedures and ...

  12. A new human eye model for ophthalmic brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Yoriyaz, H.; Sanchez, A.; Dos Santos, A.

    2005-01-01

    The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new model includes detailed description of internal structures that were not treated in previous works, allowing dose determination in different regions of the eye for a more adequate clinical analysis. Dose calculations were determined with the MCNP-4C Monte Carlo particle transport code running n parallel environment using PVM. The Amersham CKA4 ophthalmic applicator has been chosen and the depth dose distribution has been determined and compared to those provide by the manufacturer. The results have shown excellent agreement. Besides, absorbed dose values due to both 125 I seeds and 60 Co plaques were obtained for each one of the different structures which compose the eye model and can give relevant information in eventual clinical analyses. (authors)

  13. Cytotoxicity of ophthalmic solutions with and without preservatives to human corneal endothelial cells, epithelial cells and conjunctival epithelial cells.

    Science.gov (United States)

    Ayaki, Masahiko; Yaguchi, Shigeo; Iwasawa, Atsuo; Koide, Ryohei

    2008-08-01

    The cytotoxicity of a range of commercial ophthalmic solutions in the presence and absence of preservatives was assessed in human corneal endothelial cells (HCECs), corneal epithelia and conjunctival epithelia using in vitro techniques. Cell survival was measured using the WST-1 assay for endothelial cells and the MTT assay for epithelial cells. Commercially available timolol, carteolol, cromoglicate, diclofenac, bromfenac and hyaluronic acid ophthalmic solutions were assessed for cytotoxicity in the presence and absence of preservatives. The preservatives benzalkonium, chlorobutanol and polysorbate were also tested. The survival of cells exposed to test ophthalmic solutions was expressed as a percentage of cell survival in the control solution (distilled water added to media) after 48 h exposure. HCEC survival was 20-30% in ophthalmic solutions diluted 10-fold. The survival of HCEC was significantly greater in all solutions in the absence of preservative than in the presence of preservative. The survival of corneal and conjunctival epithelia was consistent with that of HCECs for all test ophthalmic solutions. The preservatives polysorbate and benzalkonium were highly cytotoxic with cell survival decreasing to 20% at the concentration estimated in commercial ophthalmic solutions. By comparison, the survival of cells exposed to chlorobutanol was 80% or greater. The cytotoxicity of ophthalmic solutions to HCEC, corneal epithelia and conjunctival epithelia decreased in the absence of preservative.

  14. Financial return-on-investment of ophthalmic interventions: a new paradigm.

    Science.gov (United States)

    Brown, Melissa M; Brown, Gary C; Lieske, Heidi B; Lieske, P Alexander

    2014-05-01

    Although the patient value gain (improvement in quality-of-life and/or length-of-life) has been highlighted in Value-based Medicine cost-utility analyses, the financial value gain associated with healthcare interventions has received less emphasis. It is important for professional healthcare providers to realize their interventions often confer a large financial return-on-investment (ROI) to society. The societal costs associated with vitreoretinal and other ophthalmic interventions include: direct ophthalmic medical costs expended (hospital, physician, drug, diagnostic testing and so forth), direct medical costs saved (decreased costs for depression, injury, skilled nursing facility, nursing home and others), direct nonmedical costs saved (decreased costs for caregivers, transportation, residence costs, moving costs, and others), and indirect medical costs saved (improving employment incidence and wages). The financial ROI for direct ophthalmic medical costs expended for ranibizumab therapy for neovascular age-related macular degeneration is 450%, whereas that for cataract surgery is 4500% and for medical open-angle glaucoma therapy is 4000%. Many costs gained add to the Gross Domestic Product and increase the wealth of the nation. Many vitreoretinal and other ophthalmologic interventions confer considerable patient value, but also result in a large financial ROI to society. This financial ROI increases the wealth of the nation.

  15. Evaluation of the cytotoxic effects of ophthalmic solutions containing benzalkonium chloride on corneal epithelium using an organotypic 3-D model.

    Science.gov (United States)

    Khoh-Reiter, Su; Jessen, Bart A

    2009-07-28

    Benzalkonium chloride (BAC) is a common preservative used in ophthalmic solutions. The aim of this study was to compare the cytotoxic effects of BAC-containing ophthalmic solutions with a BAC-free ophthalmic solution using an organotypic 3-dimensional (3-D) corneal epithelial model and to determine the effects of latanoprost ophthalmic solution and its BAC-containing vehicle on corneal thickness in a monkey model. The cytotoxicity of commercially available BAC-containing ophthalmic formulations of latanoprost (0.02% BAC) and olopatadine (0.01% BAC) was compared to that of BAC-free travoprost and saline in a corneal organotypic 3-D model using incubation times of 10 and 25 minutes. To compare the extent of differentiation of 3-D corneal cultures to monolayer transformed human corneal epithelial (HCE-T) cell cultures, expression levels (mRNA and protein) of the corneal markers epidermal growth factor receptor, transglutaminase 1 and involucrin were quantified. Finally, latanoprost ophthalmic solution or its vehicle was administered at suprapharmacologic doses (two 30 microL drops twice daily in 1 eye for 1 year) in monkey eyes, and corneal pachymetry was performed at baseline and at weeks 4, 13, 26 and 52. In the 3-D corneal epithelial culture assays, there were no significant differences in cytotoxicity between the BAC-containing latanoprost and olopatadine ophthalmic solutions and BAC-free travoprost ophthalmic solution at either the 10- or 25-minute time points. The 3-D cultures expressed higher levels of corneal epithelial markers than the HCE-T monolayers, indicating a greater degree of differentiation. There were no significant differences between the corneal thickness of monkey eyes treated with latanoprost ophthalmic solution or its vehicle (both containing 0.02% BAC) and untreated eyes. The lack of cytotoxicity demonstrated in 3-D corneal cultures and in monkey studies suggests that the levels of BAC contained in ophthalmic solutions are not likely to cause

  16. Evaluation of the cytotoxic effects of ophthalmic solutions containing benzalkonium chloride on corneal epithelium using an organotypic 3-D model

    Directory of Open Access Journals (Sweden)

    Jessen Bart A

    2009-07-01

    Full Text Available Abstract Background Benzalkonium chloride (BAC is a common preservative used in ophthalmic solutions. The aim of this study was to compare the cytotoxic effects of BAC-containing ophthalmic solutions with a BAC-free ophthalmic solution using an organotypic 3-dimensional (3-D corneal epithelial model and to determine the effects of latanoprost ophthalmic solution and its BAC-containing vehicle on corneal thickness in a monkey model. Methods The cytotoxicity of commercially available BAC-containing ophthalmic formulations of latanoprost (0.02% BAC and olopatadine (0.01% BAC was compared to that of BAC-free travoprost and saline in a corneal organotypic 3-D model using incubation times of 10 and 25 minutes. To compare the extent of differentiation of 3-D corneal cultures to monolayer transformed human corneal epithelial (HCE-T cell cultures, expression levels (mRNA and protein of the corneal markers epidermal growth factor receptor, transglutaminase 1 and involucrin were quantified. Finally, latanoprost ophthalmic solution or its vehicle was administered at suprapharmacologic doses (two 30 μL drops twice daily in 1 eye for 1 year in monkey eyes, and corneal pachymetry was performed at baseline and at weeks 4, 13, 26 and 52. Results In the 3-D corneal epithelial culture assays, there were no significant differences in cytotoxicity between the BAC-containing latanoprost and olopatadine ophthalmic solutions and BAC-free travoprost ophthalmic solution at either the 10- or 25-minute time points. The 3-D cultures expressed higher levels of corneal epithelial markers than the HCE-T monolayers, indicating a greater degree of differentiation. There were no significant differences between the corneal thickness of monkey eyes treated with latanoprost ophthalmic solution or its vehicle (both containing 0.02% BAC and untreated eyes. Conclusion The lack of cytotoxicity demonstrated in 3-D corneal cultures and in monkey studies suggests that the levels of BAC

  17. 21 CFR 524.390a - Chloramphenicol ophthalmic ointment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS... treatment for 48 hours (2 days) after eye appears normal. Therapy for cats should not exceed 7 days... therapy should be considered. When infection may be cause of disease, especially in purulent or catarrhal...

  18. Doppler sonographic evaluation of ophthalmic arterial flow pattern in hypertensive patients

    International Nuclear Information System (INIS)

    Ryu, Dae Sik; Kim, Young Goo

    1994-01-01

    To compare the Doppler velocity waveform pattern of ophthalmic artery of hypertensive patients with that of normotensive subjects. Doppler velocity waveform was obtained from ophthalmic artery in 45 hypertensive patients and 60 normotensive subjects. Both hypertensives and normotensive subjects were classified according to age into those younger than and those older than 45 years. Doppler indices(pulsatility index(PI), resistance index(RI), the first systolic peak/the second systolic peak(S1/S2), the first systolic peak/diastolic peak(S1/D)) measured in hypertensive patients were compared with normotensive subjects. Among the various doppler indices, only S1/S2 showed significant difference(P < 0.05) between the hypertensive patients and normotensive subjects younger than 45 years. Doppler velocity waveform of hypertensive patients older than 45 years showed no significant difference from that of normotensive subjects with corresponding age. Doppler velocity waveform of ophthalmic artery in hypertensive patients younger than 45 years shows pattern with S2 higher than that of normotensive subjects. High S2 component(reflective-wave) may represent increased vascular impedance due to vasococonstriction of retinal arterioles in hypertensive patients

  19. New Zealand health reforms: effect on ophthalmic practice.

    Science.gov (United States)

    Raynel, S; Reynolds, H

    1999-01-01

    Are specialized ophthalmic units with inpatient facilities going to disappear in the New Zealand public health system? We have entered the era of cost containment, business methodologies, bench marking, day case surgery, and technologic advances. The dilemma for nursing is maintenance of a skill base with dwindling clinical practice areas.

  20. Gatifloxacin Ophthalmic Solution for Treatment of Bacterial Conjunctivitis: Safety, Efficacy and Patient Perspective

    OpenAIRE

    Clyde Schultz

    2012-01-01

    Gatifloxacin is a fourth generation fluroquinolone antibiotic that has been prescribed for systemic use. However, the drug which was developed by Kyorin (Japan) was linked to toxic reactions and death and was banned in the United States and Canada for use as an oral dosage form. It continues to be used as a topical application for ophthalmic conditions as the systemic toxicity seen when taking the drug orally has not been observed with ophthalmic use. The available data indicate that ocular u...

  1. Ophthalmic Morbidity in School Children in Hilly Areas of Uttarakhand

    Directory of Open Access Journals (Sweden)

    Surekha Kishore

    2014-03-01

    Full Text Available Introduction: School children constitute about one fourth of population of India. Early detection and treatment of various eye diseases helps in avoiding many complications. The magnitude of blindness is 3-4 times greater in developing countries. Very few studies have been conducted in Uttarakhand revealing the ophthalmic morbidity in school children or general population. Hilly areas especially the remote ones face various problems like, poor transportation facilities, distant health facilities, use of traditional methods for treatment, faith healing, customs and belief system, lack of information.  Moreover   water supply, poor personal hygiene and other factors also add up to these problems. Aim: To study the ophthalmic morbidities in school children in 3 schools of Thatyur block. Methodology: It was a cross sectional study. Result: A total of 705 students were enrolled. Permission from school authorities was seeked before the start of study. Schools were visited twice in a week current and preliminary information was taken from the students & teacher regarding education, occupation, income etc. General examination and ophthalmic examination was done with day & torch light along with refraction, with the help of standard Snellen’s chart. Each eye was examined separately. A vision of 6/6 was considered as normal. Near vision was tested with new vision Snellen’s chart at 12-14 inches away from eye.

  2. Ophthalmic Morbidity in School Children in Hilly Areas of Uttarakhand

    Directory of Open Access Journals (Sweden)

    Surekha Kishore

    2014-03-01

    Full Text Available Introduction: School children constitute about one fourth of population of India. Early detection and treatment of various eye diseases helps in avoiding many complications. The magnitude of blindness is 3-4 times greater in developing countries. Very few studies have been conducted in Uttarakhand revealing the ophthalmic morbidity in school children or general population. Hilly areas especially the remote ones face various problems like, poor transportation facilities, distant health facilities, use of traditional methods for treatment, faith healing, customs and belief system, lack of information.  Moreover   water supply, poor personal hygiene and other factors also add up to these problems. Aim: To study the ophthalmic morbidities in school children in 3 schools of Thatyur block. Methodology: It was a cross sectional study. Result: A total of 705 students were enrolled. Permission from school authorities was seeked before the start of study. Schools were visited twice in a week current and preliminary information was taken from the students & teacher regarding education, occupation, income etc. General examination and ophthalmic examination was done with day & torch light along with refraction, with the help of standard Snellen’s chart. Each eye was examined separately. A vision of 6/6 was considered as normal. Near vision was tested with new vision Snellen’s chart at 12-14 inches away from eye.

  3. Re-evaluation of Magnetic Resonance and Computerised Tomographic Imaging in Neuro-Ophthalmic Patients in an Academic Centre

    NARCIS (Netherlands)

    Koekoek, Clarence G. J.; Meiners, Linda C.; Pott, Jan Willem R.

    The aim of the study is to report the frequency of missed diagnoses on magnetic resonance and computerised tomographic imaging in neuro-ophthalmic patients who were referred to an academic ophthalmology department, with apparent normal imaging. The authors included all neuro-ophthalmic patients,

  4. Oxidative-stress detoxification and signalling in cyanobacteria: the crucial glutathione synthesis pathway supports the production of ergothioneine and ophthalmate.

    Science.gov (United States)

    Narainsamy, Kinsley; Farci, Sandrine; Braun, Emilie; Junot, Christophe; Cassier-Chauvat, Corinne; Chauvat, Franck

    2016-04-01

    Using genetics and metabolomics we investigated the synthesis (gshA and gshB genes) and catabolism (ggt) of the conserved antioxidant glutathione in the model cyanobacterium Synechocystis PCC6803. These three genes are crucial to Synechocystis, in agreement with the proposed invention of glutathione by ancient cyanobacteria to protect themselves against the toxicity of oxygen they produced through photosynthesis. Consistent with their indispensability, gshA and gshB also operate in the production of another antioxidant, ergothioneine, as well as of the glutathione analogues ophthalmate and norophthalmate. Furthermore, we show that glutathione, ophthalmate and norophthalmate are accumulated in cells stressed by glucose, and that the two glutathione-dependent glyoxalase enzymes operate in the protection against glucose and its catabolite methylglyoxal. These findings are interesting because ophthalmate and norophthalmate were observed only in mammals so far, where ophthalmate is regarded as a biomarker of glutathione depletion. Instead, our data suggest that ophthalmate and norophthalmate are stress-induced markers of cysteine depletion triggered by its accelerated incorporation into glutathione, to face its increased demand for detoxification purposes. Hence, Synechocystis is an attractive model for the analysis of the role of glutathione, ergothioneine, ophthalmate and norophthalmate, in signalling and detoxification of oxidants and metabolic by-products. © 2015 John Wiley & Sons Ltd.

  5. Ophthalmic manifestations of head injury.

    Science.gov (United States)

    Kowal, L

    1992-02-01

    Head injuries are frequently associated with ophthalmic problems. The commonest problems seen in this series of 161 patients with head injury were problems with poor accommodation (16% of patients; 58% of these persisted), convergence (14% of patients; 35% of these persisted), pseudomyopia (19%; 55% persisted) and optic atrophy (26% of the patients; 78% of these were mild and easily missed on routine testing, and 22% were severe). Motility disorders were common, especially cranial nerve palsies. Other less frequent motility disturbances included apparent inferior oblique palsy, comitant esotropia, and exotropia which was often of the convergence insufficiency type.

  6. Outpatients flow management and ophthalmic electronic medical records system in university hospital using Yahgee Document View.

    Science.gov (United States)

    Matsuo, Toshihiko; Gochi, Akira; Hirakawa, Tsuyoshi; Ito, Tadashi; Kohno, Yoshihisa

    2010-10-01

    General electronic medical records systems remain insufficient for ophthalmology outpatient clinics from the viewpoint of dealing with many ophthalmic examinations and images in a large number of patients. Filing systems for documents and images by Yahgee Document View (Yahgee, Inc.) were introduced on the platform of general electronic medical records system (Fujitsu, Inc.). Outpatients flow management system and electronic medical records system for ophthalmology were constructed. All images from ophthalmic appliances were transported to Yahgee Image by the MaxFile gateway system (P4 Medic, Inc.). The flow of outpatients going through examinations such as visual acuity testing were monitored by the list "Ophthalmology Outpatients List" by Yahgee Workflow in addition to the list "Patients Reception List" by Fujitsu. Patients' identification number was scanned with bar code readers attached to ophthalmic appliances. Dual monitors were placed in doctors' rooms to show Fujitsu Medical Records on the left-hand monitor and ophthalmic charts of Yahgee Document on the right-hand monitor. The data of manually-inputted visual acuity, automatically-exported autorefractometry and non-contact tonometry on a new template, MaxFile ED, were again automatically transported to designated boxes on ophthalmic charts of Yahgee Document. Images such as fundus photographs, fluorescein angiograms, optical coherence tomographic and ultrasound scans were viewed by Yahgee Image, and were copy-and-pasted to assigned boxes on the ophthalmic charts. Ordering such as appointments, drug prescription, fees and diagnoses input, central laboratory tests, surgical theater and ward room reservations were placed by functions of the Fujitsu electronic medical records system. The combination of the Fujitsu electronic medical records and Yahgee Document View systems enabled the University Hospital to examine the same number of outpatients as prior to the implementation of the computerized filing system.

  7. 21 CFR 524.1484a - Neomycin sulfate ophthalmic ointment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS...) Severe infections should be supplemented by systemic therapy. (5) Prolonged administration of the drug... bacteria or fungi appear during therapy, appropriate measures should be taken. (6) Federal law restricts...

  8. Management of ocular inflammation and pain following cataract surgery: focus on bromfenac ophthalmic solution

    OpenAIRE

    Cho, Hyung; Wolf, Kenneth J; Wolf, Eric J

    2009-01-01

    Hyung Cho1, Kenneth J Wolf1, Eric J Wolf21Department of Ophthalmology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, USA; 2Department of Ophthalmology, Edward S. Harkness Eye Institute of Columbia University College of Physicians and Surgeons, New York, NY, USAAbstract: Recently, several new ophthalmic NSAID products have been introduced for commercial use in the United States. The purpose of this review is to briefly overview the ophthalmic NSAIDs currently...

  9. Longitudinal ophthalmic findings in a child with Helsmoortel-Van der Aa Syndrome

    Directory of Open Access Journals (Sweden)

    Michael J. Gale

    2018-06-01

    Full Text Available Purpose: We present the first detailed ophthalmic description of a child with Helsmoortel-Van der Aa Syndrome (HVDAS, including longitudinal follow-up and analysis. Observations: After extensive workup, a young child with poor visual behavior, hypotonic cerebral palsy, intellectual disability, and global developmental delay was found to have a heterozygous de novo mutation in the ADNP gene and diagnosed with HVDAS. Ophthalmic findings were remarkable for progressive nystagmus, macular pigment mottling, mild foveal hypoplasia with abnormal macular laminations, persistent rod dysfunction with electronegative waveform, and progressive cone degeneration. Conclusions and importance: Patients with HVDAS are known to have abnormal visual behavior due to refractive or cortical impairment. However, we present the first description, to our knowledge, of an association with retinal mal-development and degeneration. Thus, patients with HVDAS should be referred for ophthalmic genetics evaluation, and HVDAS should be on the differential diagnosis for young children with global developmental delay who present with nystagmus, rod and cone dysfunction with electronegative waveform, and relative lack of severe structural degeneration on optical coherence tomography. Keywords: Helsmoortel-Van der Aa Syndrome, HVDAS, Activity-dependent neuroprotective protein, ADNP, Nystagmus, Retinal degeneration, Electronegative waveform, Optical coherence tomography

  10. Diagnosis, treatment, and outcome of and risk factors for ophthalmic disease in leopard geckos (Eublepharis macularius) at a veterinary teaching hospital: 52 cases (1985-2013).

    Science.gov (United States)

    Wiggans, K Tomo; Sanchez-Migallon Guzman, David; Reilly, Christopher M; Vergneau-Grosset, Claire; Kass, Philip H; Hollingsworth, Steven R

    2018-02-01

    OBJECTIVE To describe diagnosis, treatment, and outcome of and risk factors for ophthalmic disease in leopard geckos (Eublepharis macularius) evaluated at a veterinary teaching hospital. DESIGN Retrospective case series. ANIMALS 112 of 144 (78%) leopard geckos that were evaluated at a veterinary teaching hospital in January 1985 through October 2013 and for which sufficient medical record information was available. PROCEDURES Information from medical records was used to identify leopard geckos with ophthalmic disease, characterize cases, and determine risk factors for the presence of ophthalmic disease. RESULTS Of the 112 leopard geckos, 52 (46%) had ophthalmic disease (mainly corneal or conjunctival disease). Female geckos were less likely to have ophthalmic disease, and there was a positive association between increasing age and ophthalmic disease. Use of a paper towel substrate, absence of any heat source, and lack of vitamin A supplementation were positively associated with a diagnosis of ophthalmic disease. Head dysecdysis was the only concurrent disorder significantly associated with ophthalmic disease. At necropsy, 5 affected leopard geckos had squamous metaplasia of the conjunctivae. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that ophthalmic disease is a common finding in leopard geckos. The cause of ocular surface disease in leopard geckos may be multifactorial, and hypovitaminosis A may be an important risk factor. Although animals receiving supplemental vitamin A were less likely to have ophthalmic disease, further understanding is required regarding the metabolism of and nutritional requirements for vitamin A in leopard geckos.

  11. The international forum of ophthalmic simulation: developing a virtual reality training curriculum for ophthalmology.

    Science.gov (United States)

    Saleh, George M; Lamparter, Julia; Sullivan, Paul M; O'Sullivan, Fiona; Hussain, Badrul; Athanasiadis, Ioannis; Litwin, Andre S; Gillan, Stewart N

    2013-06-01

    To investigate the effect of a structured, supervised, cataract simulation programme on ophthalmic surgeons in their first year of training, and to evaluate the level of skill transfer. Trainees with minimal intraocular and simulator experience in their first year of ophthalmology undertook a structured, sequential, customised, virtual reality (VR) cataract training programme developed through the International Forum of Ophthalmic Simulation. A set of one-handed, bimanual, static and dynamic tasks were evaluated before and after the course and scores obtained. Statistical significance was evaluated with the Wilcoxon sign-rank test. The median precourse score of 101.50/400 (IQR 58.75-145.75) was significantly improved after completing the training programme ((postcourse score: 302/400, range: 266.25-343), p<0.001). While improvement was evident and found to be statistically significant in all parameters, greatest improvements were found for capsulorhexis and antitremor training ((Capsulorhexis: precourse score=0/100, range 0-4.5; postcourse score=81/100, range 13-87.75; p=0.002), (antitremor training: precourse score=0/100, range 0-0; postcourse score=80/100, range 60.25-91.50; p=0.001)). Structured and supervised VR training can offer a significant level of skills transfer to novice ophthalmic surgeons. VR training at the earliest stage of ophthalmic surgical training may, therefore, be of benefit.

  12. Microsurgical treatment of carotid-ophthalmic aneurysm associated with multiple anterior and posterior circulation aneurysms

    Science.gov (United States)

    Wang, Jiantao; Kan, Zhisheng; Wang, Shuo

    2017-01-01

    Abstract Background: The clipping of multiple intracranial aneurysms in 1 stage is uncommon. In this case, we report clipping of an ophthalmic aneurysm associated with multiple anterior and posterior circulation aneurysms via the Dolenc approach. Methods: The main symptoms of the patient are headache, along with nausea and vomiting. The patient's arteriogram revealed a wide-necked aneurysm of the right ophthalmic artery, an irregular aneurysm of the anterior communicating artery, and a basilar artery aneurysm. The surgical intervention for these aneurysms is a challenge because of the complex anatomical relationship with the surrounding structures. The 3 aneurysms, which were not amenable to a single intervention, were successfully clipped in 1 incision. Results: After surgery, the patient reported feeling well. One year after surgery, the patient had no SAH recurrence. Conclusions: Occasionally, surgical treatment was used even for aneurysms of the carotid-ophthalmic artery with aneurysms of anterior communicating artery and basilar artery, which are contraindicated for interventional therapy. PMID:28422878

  13. [Optimization of benzalkonium chloride concentration in 0.0015% tafluprost ophthalmic solution from the points of ocular surface safety and preservative efficacy].

    Science.gov (United States)

    Asada, Hiroyuki; Takaoka-Shichijo, Yuko; Nakamura, Masatsugu; Kimura, Akio

    2010-06-01

    Optimization of benzalkonium chloride (alkyl dimethylbenzylammonium chloride: BAK) concentration as preservative in 0.0015% tafluprost ophthalmic solution (Tapros 0.0015% ophthalmic solution), an anti-glaucoma medicine, was examined from the points of ocular surface safety and preservative efficacy. BAKC(12), which is dodecyl dimethylbenzylammonium chloride, and BAKmix, which is the mixture of dodecyl, tetradecyl and hexadecyl dimethylbenzylammonium chloride were used in this study. The effects of BAKC(12) concentrations and the BAK types, BAKC(12) and BAKmix, in tafluprost ophthalmic solution on ocular surface safety were evaluated using the in vitro SV 40-immobilized human corneal epithelium cell line (HCE-T). Following treatments of Tafluprost ophthalmic solutions with BAKC(12), its concentration dependency was observed on cell viability of HCE-T. The cell viability of HCE-T after treatment of these solutions with 0.001% to 0.003% BAKC(12) for 5 minutes were the same level as that after treatment of the solution without BAK. Tafluprost ophthalmic solution with 0.01% BAKC(12) was safer for the ocular surface than the same solution with 0.01% BAKmix. Preservatives-effectiveness tests of tafluprost ophthalmic solutions with various concentrations of BAKC(12) were performed according to the Japanese Pharmacopoeia (JP), and solutions with more than 0.0005% BAKC(12) conformed to JP criteria. It was concluded that 0.0005% to 0.003% of BAKC(12) in tafluprost ophthalmic solution was optimal, namely, well-balanced from the points of ocular surface safety and preservative efficacy.

  14. 21 CFR 524.390d - Chloramphenicol-prednisolone ophthalmic ointment.

    Science.gov (United States)

    2010-04-01

    .... 017030 in § 510.600(c) of this chapter. (c) Conditions of use. Dogs and cats—(1) Amount. Apply 4 to 6...) Limitations. Therapy for cats should not exceed 7 days, prolonged use in cats may produce blood dyscrasia. As... institute appropriate therapy. All topical ophthalmic preparations containing corticosteroids, with or...

  15. The Use of Flow Diverting Stents to Treat Para-Ophthalmic Aneurysms

    Directory of Open Access Journals (Sweden)

    Pervinder Bhogal

    2017-08-01

    Full Text Available Background and purposeFew publications have dealt exclusively with the use of flow diverter stents for the treatment of para-ophthalmic aneurysms. We sought to determine the efficacy of flow diverting stents (FDSs to treat aneurysms in this specific location.MethodsWe retrospectively reviewed our database of prospectively collected information for all patients treated with flow diversion for an unruptured saccular para-ophthalmic aneurysm between September 2009 and January 2016. The aneurysm fundus size, neck size, number and type of FDS, complications, and follow-up data were recorded.ResultsWe identified 74 patients that matched our inclusion criteria. Of these patients, 18 patients were male (24.3%. The average fundus size was 4.8 mm, 11 aneurysms had previous coil occlusions and 63 were treated solely with flow diversion. At an initial angiographic follow-up (mean avg. 3.2 months, 71.8% of the aneurysms were occluded, and at the last follow-up (mean avg. 31.8 months, 88.9% of aneurysms were occluded. One patient suffered permanent morbidity (1.36% secondary to interruption of the antiplatelet medication and another died (1.36% secondary to in-stent thrombosis that was also due to an interruption in the antiplatelet medication.ConclusionTreatment of saccular para-ophthalmic aneurysms with FDS is feasible and carries a high degree of technical success with low complication rates and excellent rates of aneurysm exclusion.

  16. Gatifloxacin Ophthalmic Solution for Treatment of Bacterial Conjunctivitis: Safety, Efficacy and Patient Perspective

    Directory of Open Access Journals (Sweden)

    Clyde Schultz

    2012-01-01

    Full Text Available Gatifloxacin is a fourth generation fluroquinolone antibiotic that has been prescribed for systemic use. However, the drug which was developed by Kyorin (Japan was linked to toxic reactions and death and was banned in the United States and Canada for use as an oral dosage form. It continues to be used as a topical application for ophthalmic conditions as the systemic toxicity seen when taking the drug orally has not been observed with ophthalmic use. The available data indicate that ocular use of gatifloxacin is safe, and effective against a broad spectrum of bacteria, including intracellular bacteria and anaerobes.

  17. Ophthalmic epidemiology in Europe

    DEFF Research Database (Denmark)

    Delcourt, Cécile; Korobelnik, Jean-François; Buitendijk, Gabriëlle H S

    2016-01-01

    The European Eye Epidemiology (E3) consortium is a recently formed consortium of 29 groups from 12 European countries. It already comprises 21 population-based studies and 20 other studies (case-control, cases only, randomized trials), providing ophthalmological data on approximately 170,000 Euro......The European Eye Epidemiology (E3) consortium is a recently formed consortium of 29 groups from 12 European countries. It already comprises 21 population-based studies and 20 other studies (case-control, cases only, randomized trials), providing ophthalmological data on approximately 170......,000 European participants. The aim of the consortium is to promote and sustain collaboration and sharing of data and knowledge in the field of ophthalmic epidemiology in Europe, with particular focus on the harmonization of methods for future research, estimation and projection of frequency and impact...

  18. Long-term ophthalmic health care in Usher syndrome type I from an ICF perspective.

    Science.gov (United States)

    Möller, Kerstin; Eriksson, Kristina; Sadeghi, André M; Möller, Claes; Danermark, Berth

    2009-01-01

    The aim was to explore ophthalmic health care in female patients with Usher Syndrome type I (USH I) over 20 years and to evaluate the relationship between the ophthalmic health care and the health state of the patients from a health perspective. A retrospective study of records from ophthalmology departments (OD) and low vision clinics (LVC) from 1985 to 2004. Assessment of the reports was performed based on the International Classification of Functioning, Disability and Health (ICF). Findings were analysed by manifest content analysis with ICF as a framework and using four themes: health care system, procedure examinations, patient's functioning and disability and procedure actions. The records of nine female patients (aged 25-39 years, 1985) with USH I were selected from the national database of USH. A great number of notes were collected (OD 344 and LVC 566). Procedure examinations were exclusively oriented towards body structure and function. All patients showed aggravated visual impairment over and above the hearing and vestibular impairment. Procedure actions were oriented towards environmental factors. No correlation was found between procedures performed and patient's experience of disability. The high degree of resource allocation was not correlated to the patients' impairment. The study indicates that the ophthalmic health care was characterised by inefficiency. This conclusion is very serious because patients very likely face severe disability and emotional difficulties. ICF is ought to be incorporated in ophthalmic health care strategy to improve the health care.

  19. Ocular and systemic pharmacokinetics of lidocaine hydrochloride ophthalmic gel in rabbits after topical ocular administration.

    Science.gov (United States)

    Liu, Bing; Ding, Li; Xu, Xiaowen; Lin, Hongda; Sun, Chenglong; You, Linjun

    2015-12-01

    Lidocaine hydrochloride ophthalmic gel is a novel ophthalmic preparation for topical ocular anesthesia. The study is aimed at evaluating the ocular and systemic pharmacokinetics of lidocaine hydrochloride 3.5 % ophthalmic gel in rabbits after ocular topical administration. Thirty-six rabbits were randomly placed in 12 groups (3 rabbits per group). The rabbits were quickly killed according to their groups at 0 (predose), 0.0833, 0.167, 0.333, 0.667, 1, 1.5, 2, 3, 4, 6, and 8 h postdose and then the ocular tissue and plasma samples were collected. All the samples were analyzed by a validated LC-MS/MS method. The test result showed that the maximum concentration (C max) of lidocaine in different ocular tissues and plasma were all achieved within 20 min after drug administration, and the data of C max were (2,987 ± 1814) μg/g, (44.67 ± 12.91) μg/g, (26.26 ± 7.19) μg/g, (11,046 ± 2,734) ng/mL, and (160.3 ± 61.0) ng/mL for tear fluid, cornea, conjunctiva, aqueous humor, and plasma, respectively. The data of the elimination half-life in these tissues were 1.5, 3.2, 3.5, 1.9, and 1.7 h for tear fluid, cornea, conjunctiva, aqueous humor, and plasma, respectively. The intraocular lidocaine levels were significantly higher than that in plasma, and the elimination half-life of lidocaine in cornea, conjunctiva, and aqueous humor was relatively longer than that in tear fluid and plasma. The high intraocular penetration, low systemic exposure, and long duration in the ocular tissues suggested lidocaine hydrochloride 3.5 % ophthalmic gel as an effective local anesthetic for ocular anesthesia during ophthalmic procedures.

  20. Paradigm Shifts in Ophthalmic Diagnostics.

    Science.gov (United States)

    Sebag, J; Sadun, Alfredo A; Pierce, Eric A

    2016-08-01

    Future advances in ophthalmology will see a paradigm shift in diagnostics from a focus on dysfunction and disease to better measures of psychophysical function and health. Practical methods to define genotypes will be increasingly important and non-invasive nanotechnologies are needed to detect molecular changes that predate histopathology. This is not a review nor meant to be comprehensive. Specific topics have been selected to illustrate the principles of important paradigm shifts that will influence the future of ophthalmic diagnostics. It is our impression that future evaluation of vision will go beyond visual acuity to assess ocular health in terms of psychophysical function. The definition of disease will incorporate genotype into what has historically been a phenotype-centric discipline. Non-invasive nanotechnologies will enable a paradigm shift from disease detection on a cellular level to a sub-cellular molecular level. Vision can be evaluated beyond visual acuity by measuring contrast sensitivity, color vision, and macular function, as these provide better insights into the impact of aging and disease. Distortions can be quantified and the psychophysical basis of vision can be better evaluated than in the past by designing tests that assess particular macular cell function(s). Advances in our understanding of the genetic basis of eye diseases will enable better characterization of ocular health and disease. Non-invasive nanotechnologies can assess molecular changes in the lens, vitreous, and macula that predate visible pathology. Oxygen metabolism and circulatory physiology are measurable indices of ocular health that can detect variations of physiology and early disease. This overview of paradigm shifts in ophthalmology suggests that the future will see significant improvements in ophthalmic diagnostics. The selected topics illustrate the principles of these paradigm shifts and should serve as a guide to further research and development. Indeed

  1. Application and study of conjunctival sac disinfectants in ophthalmic surgeries

    Directory of Open Access Journals (Sweden)

    Yan-Fei Luo

    2016-01-01

    Full Text Available Postoperative endophthalmitis is the most serious complications of ophthalmic surgeries. Conjunctival sac disinfection is currently recognized as an effectively important way to reduce the risk of endophthalmitis. At present, there are some disinfectants has been used in clinic or in the researches:mercury agent, gentamicin, povidone iodine and acid electrolytic water. All kinds of disinfectants play the role of disinfection by different ways. Povidone iodine is the most widely used conjunctival sac disinfectant. Mercurial and gentamicin have been rarely used because they pollute the environment, are easy to cause drug resistant bacteria, localized side reactions and so on. The acid electrolyte water is not used in clinic at present. With the popularization and development of the ophthalmic surgeries, the ophthalmologists have become more and more concerned about the postoperative eye comfort, the research and application of conjunctival sac disinfectant in the future will continue to be updated and developed.

  2. Optimization and evaluation of thermoresponsive diclofenac sodium ophthalmic in situ gels.

    Science.gov (United States)

    Asasutjarit, Rathapon; Thanasanchokpibull, Suthira; Fuongfuchat, Asira; Veeranondha, Sukitaya

    2011-06-15

    This work was conducted to optimize and evaluate Pluronic F127-based thermoresponsive diclofenac sodium ophthalmic in situ gels (DS in situ gel). They were prepared by cold method and investigated their physicochemical properties i.e., pH, flow ability, sol-gel transition temperature, gelling capacity and rheological properties. An optimized formulation was selected and investigated its physicochemical properties before and after autoclaving, eye irritation potency in SIRC cells and rabbits. In vivo ophthalmic absorption was performed in rabbits. It was found that physicochemical properties of DS in situ gels were affected by formulation compositions. Increment of Pluronic F127 content decreased sol-gel transition temperature of the products while increase in Pluronic F68 concentration tended to increase sol-gel transition temperature. In this study, Carbopol 940 did not affect sol-gel transition temperature but it affected transparency, pH, and gelling capacity of the products. The optimized formulation exhibited sol-gel transition at 32.6 ± 1.1 °C with pseudoplastic flow behavior. It was lost diclofenac sodium content during autoclaving. However, it was accepted as safe for ophthalmic use and could increase diclofenac sodium bioavailability in aqueous humor significantly. In conclusion, the optimized DS in situ gel had potential for using as an alternative to the conventional diclofenac sodium eye drop. However, autoclaving was not a suitable sterilization method for this product. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Local toxicity of benzalkonium chloride in ophthalmic solutions following repeated applications.

    Science.gov (United States)

    Okahara, Akihiko; Kawazu, Kouichi

    2013-01-01

    We performed repeated toxicity studies of benzalkonium chloride (BAK)-containing vehicles of ophthalmic solutions in monkeys and rabbits to assess the local toxicity of BAK after repeated applications on the ocular surface. Local toxicity of BAK was evaluated by toxicity studies in which a 0.01% BAK-containing vehicle was applied twice/day for 52 weeks, 4 times/day for 39 weeks, or 6 times/day for 13 weeks, or in which a 0.005% BAK-containing vehicle was applied 6 times/day for 52 weeks or twice/day for 4 weeks in monkeys. Local toxicity of BAK was also evaluated where a 0.01% BAK-containing vehicle was applied 6 times/day for 6 weeks, or a 0.005% BAK-containing vehicle was applied twice/day for 39 weeks or 8 times/day for 4 weeks in rabbits. These doses were chosen because BAK is generally used at concentrations up to 0.01% in ophthalmic solutions. The BAK-containing vehicle did not cause ophthalmological changes suggestive of irritation, allergy, or corneal damage. We also did not observe any histopathological changes in the eyeball, eyelid, lacrimal gland, and nasal cavity, with repeated applications of BAK for up to 52 weeks, up to 8 times/day, or at concentrations up to 0.01%, in monkeys and rabbits. Our results suggest that BAK in concentrations up to 0.01% in ophthalmic solution is non-toxic to the eyeball, its accessory organs, and the nasal cavity after long repeated applications.

  4. [Sinus pericranii associated to spontaneous thrombosis of the ophthalmic vein: neuroimaging studies].

    Science.gov (United States)

    Murias, E; Villota, E; Saiz, A; Gil, A; Calleja, S

    2009-01-01

    Sinus pericranii is an abnormal venous communication between the intracranial dural sinuses and epicranial venous dilatations. The periorbital location is uncommon; spontaneous partial thromboses of the subcutaneous varices have been reported in association with local signs and symptoms; however, to our knowledge there are no reports of sinus pericranii associated to thrombosis in the ophthalmic vein. Sinus pericranii is related to arteriovenous and lymphatic-venous malformations. We present the case of a patient with a generalized and diffuse disorder of venous drainage that affected the right cerebral hemisphere who presented at the emergency department with ophthalmologic signs and symptoms after thrombosis of the superior ophthalmic vein and who had three sinus pericranii located in the frontal, parietal, and occipital areas.

  5. Antimicrobial activity of a new preservative for multiuse ophthalmic solutions.

    Science.gov (United States)

    Ghelardi, Emilia; Celandroni, Francesco; Gueye, Sokhna A; Salvetti, Sara; Campa, Mario; Senesi, Sonia

    2013-01-01

    The aim of this study was to examine the antimicrobial activity and the preservative efficacy of a novel preservative solution containing sodium hydroxymethyl glycinate (SHMG) and edetate disodium (EDTA), which is used for preservation of some commercial ophthalmic formulations. In vitro susceptibility assays were performed against several gram-positive (Staphylococcus aureus, Staphylococcus epidermidis, and Bacillus cereus) and gram-negative (Escherichia coli and Pseudomonas aeruginosa) bacteria representative of the microbial flora of epithelial surfaces or colonizing the conjunctiva, as well as against Candida albicans and Aspergillus niger. Using different concentrations of SHMG alone or in combination with EDTA, the minimal inhibitory and microbicidal concentrations against these organisms were assessed. In addition, 8 brands of multidose eye drops containing 0.002% SHMG and 0.1% EDTA as preservative were tested for antimicrobial activity using the antimicrobial effectiveness test recommended by the international pharmacopoeias. The minimal inhibitory and bactericidal/fungicidal concentration values of SHMG ranged from 0.0025% to 0.0125% for bacteria and from 0.125% to 0.50% for mold and yeast. Susceptibility testing demonstrated that the addition of EDTA substantially increased the SHMG activity against all bacterial and fungal strains. The preservative effectiveness test was applied to commercial eye drops. All the drop solutions met the criteria reported by the U.S. Pharmacopeia for parenteral and ophthalmic preparations. All products also satisfied the major acceptance criteria of the European Pharmacopeia with respect to the antifungal activity. With regard to the antibacterial activity, the less-stringent criteria of the European Pharmacopeia were fulfilled. The present study demonstrates the efficacy of a novel preservative for ophthalmic solutions (SHMG/EDTA) and its activity in protecting selected commercial artificial tears against microbial

  6. Ophthalmic manifestations of methylmalonic aciduria accompanied with homocystinuria

    Directory of Open Access Journals (Sweden)

    Qiu-Jing Huang

    2015-12-01

    Full Text Available Methylmalonicaciduia(MMAaccompanied with homocystinuria is a rare autosomal-recessive with congenital metabolic disorder of Vitamin B12. There are three subtypes, cblC, cblD, cblF, in which cblC is the most common one. The diagnostic tests are tandem mass spectrometry and gas chromatography-mass spectrometry. Tests for activity of enzyme in fibroblasts from skin, complementary assay and genetic analysis can be used to make the subtype clear. Early-onset patients, defined by onset of symptoms before the age of 1 year, may have severe ocular involvement, including visual loss, nystagmus, strabismus, retinopathy, maculopathy, optic atrophy, abnormal electroretinography. Late-onset patients, defined by onset of symptoms after the age of 4 year, rarely have ocular manifestations. The pathogenesis of the ophthalmic symptoms may be related to the high level of homocystine, oxidative stress and the abnormal development of nervous systems. The treatment for MMA accompanied with homocystinuria is mostly symptomatic based. Ophthalmic treatment is limited. Early supplement of methionine,GSH or other antioxidants may be helpful for retinopathy. There is no standard ophthalmological examination for those patients in China. It is critical to set up inter-departmental cooperation and early stage examination for the treatments and outcomes of the patients.

  7. Ophthalmic Skills Assessment of Primary Health Care Workers at ...

    African Journals Online (AJOL)

    Proficiency in the basic ophthalmic skills is a cri cal factor in the effec ve delivery of eye care services at the primary level of care. The aim of the study was to assess the ability of ... out visual acuity test and correctly iden fy cataract and conjunc vi s using pictures of eye condi ons and ..... Medical Laboratory Technician.

  8. Does Uniformity of Topical Corticosteroid Ophthalmic Medications: Flourometholone Acetate 0.1 Suspension and Loteprednol Etabonate 0.5 gel

    Science.gov (United States)

    2017-01-03

    following ocular surgery.1 They are available in different forms including emulsions , ointments, solutions, gels, and suspensions. The choice of...study done by Stringer and Bryant compared dose uniformity of difluprednate ophthalmic emulsion (Durezol®) with prednisolone acetate (brand name...topical ophthalmic corticosteroid suspensions. Am J Ophthalmol. 1979;87(2): 210- 214. 5 Flarex® [ package insert]. Fort Worth, TX: Alcon Laboratories Inc

  9. Clinical utility of 3% diquafosol ophthalmic solution in the treatment of dry eyes

    Science.gov (United States)

    Koh, Shizuka

    2015-01-01

    Diquafosol is a drug used for dry eye treatment with a novel mechanism of action. It stimulates the secretion of tear fluid and mucin on the ocular surface, thus enabling us to selectively treat the tear film layer, playing an important role in the establishment of the concept of “Tear Film Oriented Therapy (TFOT)”, an effective therapeutic approach to dry eye in Japan. The 3% diquafosol ophthalmic solution has been widely used for the treatment of dry eye in clinical practice, and it is currently available in Japan and South Korea. This review provides an overview of the clinical utility of 3% diquafosol ophthalmic solution, focusing on the results of clinical studies on various types of dry eye, including aqueous-deficient dry eye, short tear film breakup time-type dry eye, and post dry eye after laser in situ keratomileusis. It also introduces the additive effect of diquafosol on sodium hyaluronate monotherapy for dry eye, and the effect of 3% diquafosol ophthalmic solution for dry eye-related conditions. Additionally, it summarizes the ocular effects of diquafosol in healthy human eyes. Lastly, the importance of improving tear film stability in dry eye treatment, as well as general advances in dry eye treatments, are described. PMID:26028958

  10. Clinical utility of 3% diquafosol ophthalmic solution in the treatment of dry eyes.

    Science.gov (United States)

    Koh, Shizuka

    2015-01-01

    Diquafosol is a drug used for dry eye treatment with a novel mechanism of action. It stimulates the secretion of tear fluid and mucin on the ocular surface, thus enabling us to selectively treat the tear film layer, playing an important role in the establishment of the concept of "Tear Film Oriented Therapy (TFOT)", an effective therapeutic approach to dry eye in Japan. The 3% diquafosol ophthalmic solution has been widely used for the treatment of dry eye in clinical practice, and it is currently available in Japan and South Korea. This review provides an overview of the clinical utility of 3% diquafosol ophthalmic solution, focusing on the results of clinical studies on various types of dry eye, including aqueous-deficient dry eye, short tear film breakup time-type dry eye, and post dry eye after laser in situ keratomileusis. It also introduces the additive effect of diquafosol on sodium hyaluronate monotherapy for dry eye, and the effect of 3% diquafosol ophthalmic solution for dry eye-related conditions. Additionally, it summarizes the ocular effects of diquafosol in healthy human eyes. Lastly, the importance of improving tear film stability in dry eye treatment, as well as general advances in dry eye treatments, are described.

  11. Common causes of red eye presenting at an ophthalmic clinic ...

    African Journals Online (AJOL)

    Background: Redness of the eye is a common ophthalmic symptom. The problem causing redness could arise from within or outside the globe. These range from cases of simple inflammation following itching and minor trauma for example, to severe cases like orbital cellulitis and tumours. Patients may not even be aware of ...

  12. Efficacy of detergent and water versus bleach for disinfection of direct contact ophthalmic lenses.

    Science.gov (United States)

    Abbey, Ashkan M; Gregori, Ninel Z; Surapaneni, Krishna; Miller, Darlene

    2014-06-01

    Although manufacturers recommend cleaning ophthalmic lenses with detergent and water and then with a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus that of bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus and 2 viral strains (adenovirus and herpes simplex virus [HSV] type-1) were individually inoculated onto 20 gonioscopy and laser lenses. The lenses were washed with detergent and water and then disinfected with 10% bleach. All the lenses were cultured after inoculation, after washing with detergent and water, and after disinfecting with the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks, and viral cultures were observed for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). All 20 lenses inoculated with S. epidermidis, C. straitum, adenovirus, and HSV-1 showed growth after inoculation but no growth after washing with detergent/water and after disinfecting with the bleach. All lenses showed positive HSV and adenovirus PCR results after inoculation and negative PCR results after washing with detergent/water and after disinfecting with bleach. All methicillin-resistant S. aureus-contaminated lenses showed growth after inoculation and no growth after washing with detergent and water. However, 1 lens showed positive growth after disinfecting with bleach. Cleaning with detergent and water seemed to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage.

  13. Facilitation of tear fluid secretion by 3% diquafosol ophthalmic solution in normal human eyes.

    Science.gov (United States)

    Yokoi, Norihiko; Kato, Hiroaki; Kinoshita, Shigeru

    2014-01-01

    To evaluate the increase in tear fluid volume induced by 3% diquafosol ophthalmic solution in normal human eyes. Prospective, randomized, double-masked, comparative study. Twenty healthy adults (17 males and 3 females; mean age, 38.8 years) underwent topical instillation of 2 ophthalmic solutions, artificial tears in 1 eye and 3% diquafosol ophthalmic solution in the fellow eye, in a masked manner. The radius of curvature of the central lower tear meniscus was measured at 5, 10, 15, 30, and 60 minutes after instillation by use of reflective meniscometry, and subjects' self-evaluated symptoms of wetness and stinging using a visual analog scale. Changes after instillation in the radius of curvature from baseline (artificial tear group vs diquafosol group; mean ± standard error of the mean) were as follows: at 5 minutes, -0.008 ± 0.012 vs 0.045 ± 0.013; at 10 minutes, 0.001 ± 0.014 vs 0.057 ± 0.016; at 15 minutes, -0.012 ± 0.014 vs 0.037 ± 0.019; at 30 minutes, -0.010 ± 0.016 vs 0.030 ± 0.025; and at 60 minutes, -0.029 ± 0.012 vs -0.020 ± 0.012. The diquafosol group showed significantly greater values from 5 to 30 minutes after instillation. Of the 40 eyes, 13 showed abnormal tear film breakup time (≤5 seconds). The diquafosol group had significantly more wetness at 15 minutes after instillation than did the artificial tear group. Topical instillation of 3% diquafosol ophthalmic solution increases tear fluid on the ocular surface for up to 30 minutes in normal human eyes. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. 21 CFR 886.1120 - Opthalmic camera.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1120 Opthalmic camera. (a) Identification. An ophthalmic camera is an AC-powered device intended to take photographs of the eye and the surrounding area...

  15. Relationship between the Direction of Ophthalmic Artery Blood Flow and Ocular Microcirculation before and after Carotid Artery Stenting.

    Science.gov (United States)

    Ishii, Masashi; Hayashi, Morito; Yagi, Fumihiko; Sato, Kenichiro; Tomita, Goji; Iwabuchi, Satoshi

    2016-01-01

    When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS) of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigate the relationship between ocular microcirculation and the direction of ophthalmic artery blood flow obtained by angiography. We found that there was a significant increase in blood flow after CAS ( P = 0.003). Peak systolic velocity as an indicator of the rate of stenosis was also significantly higher in the group with retrograde/undetected flow of the ophthalmic artery than in the group with antegrade flow ( P = 0.002). In all cases where retrograde flow of the ophthalmic artery was observed before stenting, the flow changed to antegrade after stenting. Through the use of laser speckle flowgraphy, this study found that CAS can improve ocular microcirculation. Furthermore, while patients displaying retrograde flow of the ophthalmic artery before stenting have a poor prognosis, CAS corrected the flow to antegrade, suggesting that visual loss can be prevented by improving the ocular microcirculation.

  16. Intraoperative floppy iris and prevalence of intraoperative complications: results from ophthalmic surgery outcomes database.

    Science.gov (United States)

    Vollman, David E; Gonzalez-Gonzalez, Luis A; Chomsky, Amy; Daly, Mary K; Baze, Elizabeth; Lawrence, Mary

    2014-06-01

    To estimate the prevalence of untoward events during cataract surgery with the use of pupillary expansion devices and intraoperative floppy iris (IFIS). Retrospective analysis of 4923 cataract surgery cases from the Veterans Affairs Ophthalmic Surgical Outcomes Data Project. Outcomes from 5 Veterans Affairs medical centers were analyzed, including use of alpha-blockers (both selective and nonselective), IFIS, intraoperative iris trauma, intraoperative iris prolapse, posterior capsular tear, anterior capsule tear, intraoperative vitreous prolapse, and use of pupillary expansion devices. P values were calculated using the χ(2) test. A total of 1254 patients (25.5%) took alpha-blockers preoperatively (selective, 587; nonselective, 627; both, 40). Of these 1254 patients, 428 patients (34.1%) had documented IFIS. However, 75.2% of patients with IFIS (428/569) had taken alpha-blockers preoperatively (P < .00001). A total of 430 patients (8.7%) had a pupillary expansion device used during their cataract surgery, of which 186 patients (43.4%) had IFIS (P < .0001). Eighty-six patients with IFIS had at least 1 intraoperative complication and 39 patients with IFIS had more than 1 intraoperative complication (P < .001). The use of either selective or nonselective alpha-antagonists preoperatively demonstrated a significant risk of IFIS. Nonselective alpha-antagonists caused IFIS at a higher prevalence than previously reported. This study did demonstrate statistically significant increased odds of surgical complications in patients with IFIS vs those without IFIS in all groups (those taking selective and nonselective alpha-antagonists and also those not taking medications). Published by Elsevier Inc.

  17. The impact of the European Working Time Regulations on Ophthalmic Specialist Training--a national trainee survey.

    Science.gov (United States)

    O'Gallagher, M K; Lewis, G; Mercieca, K; Moutray, T

    2013-01-01

    To assess ophthalmic trainees' perspective of the impact of the European Working Time Regulations (EWTR) on their training. All trainees in ophthalmology in the UK were emailed a link to an electronic survey asking about their experiences of the EWTR. 324 trainees (46% of those invited) responded to the survey. 44.4% of trainees reported that their posts were compliant with the EWTR. 40.7% felt that training had been adversely affected. 49.1% thought that ophthalmic trainees should opt out of the EWTR to work more than 48 h per week, with 57 the mean number of hours suggested appropriate. Many ophthalmic trainees in the United Kingdom are working in rotas which are not compliant with the European Working Time Directive. Many trainees feel that implementation of the EWTD has had a negative effect on training and feel it would be acceptable to work a higher number of hours per week. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Bromfenac ophthalmic solution for the treatment of postoperative ocular pain and inflammation: safety, efficacy, and patient adherence

    OpenAIRE

    Rajpal, Rajesh K; Ross, Bryan; Rajpal, Sachin D; Hoang, Khoa

    2014-01-01

    Rajesh K Rajpal, Bryan Ross, Sachin D Rajpal, Khoa HoangSee Clearly Vision Group, McLean, VA, USAAbstract: Ophthalmic nonsteroidal anti-inflammatory drugs (NSAIDs) are commonly used by clinicians to manage ocular inflammation and pain following cataract surgery. Over the past decade, the US Food and Drug Administration has approved multiple topical NSAIDs for these purposes, including several reformulated products. One of these medications, bromfenac ophthalmic solution, has a long and extens...

  19. OPHTHALMIC FINDINGS IN LATE STAGE SJOGREN-LARSSON SYNDROME.

    Science.gov (United States)

    Nanda, Tavish; Kovach, Jaclyn L

    2017-03-15

    To report spectral domain optical coherence tomography and fundus autofluorescence documentation of late stage macular findings associated with Sjogren-Larsson Syndrome in three adult siblings. Three adult siblings with Sjogren-Larsson Syndrome underwent ophthalmic examination and imaging. Crystalline maculopathy and subretinal deposits, presumably lipofuscin accumulation, with macular atrophy were present in varying degrees in all three adult siblings. In adults with Sjogren-Larsson Syndrome, crystalline retinopathy can progress to macular atrophy and the appearance of lipofuscin accumulation.

  20. Efficacy of Detergent and Water Versus Bleach for the Disinfection of Direct Contact Ophthalmic Lenses

    Science.gov (United States)

    Abbey, Ashkan M.; Gregori, Ninel Z.; Surapaneni, Krishna; Miller, Darlene

    2014-01-01

    Purpose While manufacturers recommend cleaning ophthalmic lenses with detergent and water and then a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Methods Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus (MRSA) and two viral strains (adenovirus and herpes simplex virus (HSV) type-1) were individually inoculated to 20 gonioscopy and laser lenses. Lenses were washed with detergent and water and then disinfected with 10% bleach. All lenses were cultured after inoculation, after detergent and water, and after the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks and viral cultures for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). Results All 20 lenses inoculated with Staphylococcus epidermidis, Corynebacterium straitum, adenovirus, and HSV-1 showed growth after inoculation, but no growth after detergent/water and after the bleach. All lenses showed positive HSV and adenovirus PCR after inoculation and negative PCR after detergent/water and after bleach. All MRSA contaminated lenses showed growth after inoculation and no growth after detergent and water. However, one lens showed positive growth after bleach. Conclusions Cleaning with detergent and water appeared to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage. PMID:24747806

  1. Design of Novel Ophthalmic Formulation Containing Drug Nanoparticles and Its Usefulness as Anti-glaucoma Drugs.

    Science.gov (United States)

    Nagai, Noriaki

    2016-01-01

    The ophthalmic application of drugs is the primary route of administration for the therapy of glaucoma; however, in traditional formulations, only small amounts of the administered drug penetrate the cornea to reach the desired intraocular tissue due to corneal barriers. Recently, nanoparticulate drug delivery is expected as a technology to overcome the difficulties in delivering drugs across biological barriers (improvement of bioavailability). In this study, we attempted to establish a new method for preparing solid drug nanoparticles by using a bead mill and various additives, and succeeded in preparing a high quality dispersion containing drug nanoparticles. For a more concrete example, a mean particle size of disulfiram (DSF) treated with bead mill is 183 nm. The corneal penetration and corneal residence time of DSF from the ophthalmic dispersion containing DSF nanoparticles were significantly higher than those from a 2-hydroxypropyl-β-cyclodextrin solution containing DSF (DSF solution). It is known that the administration of DSF has intraocular pressure (IOP)-reducing effects. The IOP-reducing effects of the ophthalmic dispersion containing DSF nanoparticles were significantly greater than those of the DSF solution in rabbits (the IOP was enhanced by placing the rabbits in a dark room for 5 h). In addition, the ophthalmic dispersion containing DSF nanoparticles is better tolerated by corneal epithelial cells than DSF solution. It is possible that dispersions containing DSF nanoparticles provide new possibilities for effectively treating glaucoma, and that ocular drug delivery systems using drug nanoparticles may expand their usage for therapy in the ophthalmologic field.

  2. Deep lateral wall orbital decompression following strabismus surgery in patients with Type II ophthalmic Graves' disease.

    Science.gov (United States)

    Ellis, Michael P; Broxterman, Emily C; Hromas, Alan R; Whittaker, Thomas J; Sokol, Jason A

    2018-01-10

    Surgical management of ophthalmic Graves' disease traditionally involves, in order, orbital decompression, followed by strabismus surgery and eyelid surgery. Nunery et al. previously described two distinct sub-types of patients with ophthalmic Graves' disease; Type I patients exhibit no restrictive myopathy (no diplopia) as opposed to Type II patients who do exhibit restrictive myopathy (diplopia) and are far more likely to develop new-onset worsening diplopia following medial wall and floor decompression. Strabismus surgery involving extra-ocular muscle recession has, in turn, been shown to potentially worsen proptosis. Our experience with Type II patients who have already undergone medial wall and floor decompression and strabismus surgery found, when additional decompression is necessary, deep lateral wall decompression (DLWD) appears to have a low rate of post-operative primary-gaze diplopia. A case series of four Type II ophthalmic Graves' disease patients, all of whom had already undergone decompression and strabismus surgery, and went on to develop worsening proptosis or optic nerve compression necessitating further decompression thereafter. In all cases, patients were treated with DLWD. Institutional Review Board approval was granted by the University of Kansas. None of the four patients treated with this approach developed recurrent primary-gaze diplopia or required strabismus surgery following DLWD. While we still prefer to perform medial wall and floor decompression as the initial treatment for ophthalmic Graves' disease, for proptosis following consecutive strabismus surgery, DLWD appears to be effective with a low rate of recurrent primary-gaze diplopia.

  3. Comparison of Descemet stripping under continuous air flow, manual air injection and balanced salt solution for DMEK: a pilot study.

    Science.gov (United States)

    Gabbay, I E; Bahar, I; Nahum, Y; Livny, E

    2017-08-01

    Descemet's membrane endothelial keratoplasty (DMEK) involves removal of the recipient's Descemet membrane (DM) prior to transplanting the donor's DM. When using balanced salt solution (BSS) or ophthalmic viscosurgical devices (OVDs), visualization of the host's DM during its stripping may be inadequate and may result in Descemet remnants and could lead to sub-optimal surgical results. Previous articles described excellent visualization when utilizing air injection but this requires repeated air injection into the anterior chamber (AC). We present a pilot study that compares different techniques under which DM stripping can be performed: with continuous automated air infusion, with manual air infusion, and with BSS. We retrospectively compared video footage of DM stripping with BSS, with continuous air and with manual injection of air into the AC to determine DM stripping duration and the number of times the surgeon had to insert and retrieve a surgical instrument from the AC. Thirty videos of 10 consecutive cases of the three DM stripping techniques were evaluated. DM stripping duration was 3.26 (±1.32), 3.92 (±1.2) and 12.9 (±3.98) minutes for BSS, continuous air flow, and manual air injection, respectively. Frequency of instrument retrieval (FIR) was 3.6 (±1.71), 1.5 (±0.71) and 15.1 (±3.28) for BSS, continuous air flow, and manual air injection, respectively. Continuous air flow and BSS were both statistically different than manual air injection into the AC (p air in the AC contributes to better visualization and an efficient surgery.

  4. 10 CFR 35.491 - Training for ophthalmic use of strontium-90.

    Science.gov (United States)

    2010-01-01

    ... the requirements in paragraph (b) of this section and has achieved a level of competency sufficient to... require the authorized user of strontium-90 for ophthalmic radiotherapy to be a physician who— (a) Is an...; (iii) Mathematics pertaining to the use and measurement of radioactivity; and (iv) Radiation biology...

  5. Influence of Ophthalmic Solutions on Tear Components.

    Science.gov (United States)

    Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko

    2016-11-01

    Tear fluids are a mixture of secretions derived from lacrimal glands, accessory lacrimal glands, conjunctiva, and meibomian glands. Compositional changes to tears occur in the normal state and during ocular surface disease, such as dry eye conditions. We have investigated compositional changes to tears after topical application of ophthalmic solutions, with regard to tear-specific proteins (secretory immunoglobulin A, lactoferrin, lipocalin-1, and lysozyme) and ocular surface mucin in normal and dry eye conditions using high-performance liquid chromatography. After application of saline solution (0.9% sodium chloride) in normal subjects, transient but significant decreases in all tear components were observed. The recovery of protein concentrations took up to 30 minutes and lasted longer when the saline solution was applied more frequently. When applying ophthalmic solutions, a balance between washout and dilutional effects should be considered in addition to the therapeutic effect. Investigation of the effect of diquafosol solution (3%) in normal subjects revealed a significant increase in sialic acid concentration, a marker of ocular mucin, at 5 minutes after application, whereas a significant decrease was observed with saline. This result indicates the accelerated secretion of mucin from ocular tissues induced by diquafosol. A clinical study to determine the efficacy of diquafosol in patients with dry eye revealed improvements in tear breakup time, keratoconjunctival staining scores, and Schirmer test score, accompanied by an increase in sialic acid concentration in tears. Investigating normal and dry eye conditions through tear analysis may clarify the pathophysiology of dry eye conditions and support the efficacy of treatments.

  6. Ophthalmic Artery Embolization as Pretreatment of Orbital Exenteration for Conjunctival Squamous Cell Carcinoma

    International Nuclear Information System (INIS)

    Matsuo, Toshihiko; Ohara, Nobuya; Namba, Yuzaburo; Koshima, Isao; Ida, Kentaro; Kanazawa, Susumu

    2009-01-01

    The aim of this study is to describe the effect of transarterial embolization from the ophthalmic artery as a pretreatment for orbital exenteration. A 75-year-old Chinese man with a 7-year history of gradual increase of the left eye swelling showed a massive conjunctival tumor growing outwardly from the interpalpebral fissure and had no light perception in the left eye. Magnetic resonance imaging showed orbital invasion of the tumor around the left eyeglobe. The initial surgery for the planned orbital exenteration was discontinued after skin incision around the orbital margin due to massive hemorrhage. The patient underwent transarterial embolization with gelatin sponge (Spongel) of the feeding arteries from the left ophthalmic artery and, the next day, had orbital exenteration with well-controllable bleeding and reconstruction with free vascularized anterolateral thigh cutaneous flap transfer. Pathologically, well-differentiated squamous cell carcinoma proliferated in exophytic, papillary, and nested fashions, arising from the bulbar conjunctiva. Tumor cells were also found in the conjunctival stroma around the vessels. The sclera at the equator had a perforated site with tumor cell invasion, but no intraocular invasion was found. Hematoxylin-positive gelatin sponges were found inside the orbital vessels and large choroidal vessels. In conclusion, transarterial embolization of feeding arteries arising from the ophthalmic artery is a useful pretreatment to control bleeding at orbital exenteration for malignancy.

  7. Flow analysis of the ophthalmic artery

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Kuniaki; Hashimoto, Masato; Bandoh, Michio; Odawara, Yoshihiro; Kamagata, Masaki; Shirase, Ryuji [Sapporo Medical Univ. (Japan). Hospital

    2003-02-01

    The purpose of this study was to analyze the hemodynamics of ophthalmic artery flow using phase contrast MR angiography (PC-MRA). A total of 14 eyes from 10 normal volunteers and a patient with normal tension glaucoma (NTG) were analyzed. The optimal conditions were time repetition (TR)/echo time (TE)/flip angle (FA)/nex=40 ms/minimum/90 deg/2, field of view (FOV)=6 cm, matrix size=256 x 256. The resistive index (RI) and pulsatillity index (PI) values were significantly raised in the patient with NTG when compared to the control group. We therefore believe that PC-MRA may be a useful clinical tool for the assessment of the mechanism of NTG. (author)

  8. Bioavailability and biochemical effects of diclofenac sodium 0.1% ophthalmic solution in the domestic chicken (Gallus gallus domesticus).

    Science.gov (United States)

    Griggs, Angela N; Yaw, Taylor J; Haynes, Joseph S; Ben-Shlomo, Gil; Tofflemire, Kyle L; Allbaugh, Rachel A

    2017-03-01

    To determine if topical ophthalmic diclofenac sodium 0.1% solution alters renal parameters in the domestic chicken, and to determine if the drug is detectable in plasma after topical ophthalmic administration. Thirty healthy domestic chickens. Over 7 days, six birds were treated unilaterally with one drop of artificial tear solution (group 1), 12 birds were treated unilaterally (group 2) and 12 bilaterally (group 3) with diclofenac sodium 0.1% ophthalmic solution. Treatments were provided every 12 h in all groups. Pre- and post-treatment plasma samples from all birds were evaluated for changes in albumin, total protein, and uric acid. Post-treatment samples of all birds, collected 15 min post-administration, were analyzed by high-performance liquid chromatography with mass spectrometry for diclofenac sodium detection. A randomly selected renal sample from each group was submitted for histopathologic review. Changes in pre- and post-treatment plasma albumin were significant (P Ophthalmic diclofenac sodium 0.1% administered topically every 12 h in one or both eyes for 7 days is detectable in systemic circulation in the domestic chicken, but does not cause overt significant changes in plasma uric acid or total protein. © 2016 American College of Veterinary Ophthalmologists.

  9. Rapid and selective removal of preservative from ophthalmic formulations during eyedrops instillation.

    Science.gov (United States)

    Hsu, Kuan-Hui; Chauhan, Anuj

    2015-11-01

    About 70% of eyedrops contain benzalkonium chloride (BAK) as a preservative to prevent the growth of microorganisms. While preservatives are mandated to maintain sterility, many patients exhibit irritation and toxicity to such compounds. We propose to mitigate the ocular toxicity in the ocular formulations without compromising sterility by designing a device that can be incorporated into an eyedrops bottle to selectively remove the preservatives during the process of drop instillation. Here, we specifically focus on macroporous poly(2-hydroxyethyl methacrylate) (pHEMA) gel due to its excellent biocompatibility and high partition coefficient for BAK. In addition to specific selectivity for BAK, the device also requires high hydraulic permeability to allow drop dispensing without excessive pressure drop. The pHEMA monolith can remove nearly 100% of contained BAK from a 25 ml, 0.012% BAK solution with negligible uptake of the hydrophilic drugs such as timolol and dorzolamide. The filter, however, had to be pre-equilibrated with hydrophobic drugs to reach a high separation of BAK without reducing the concentration of the active drug. The average hydraulic permeability of the filter was 0.025 Darcy, which is about 5-fold lower than the ideal value. Incorporation of a pHEMA macroporous gel into an eyedrops bottle can virtually eliminate the exposure of the eyes to the preservatives without compromising the sterility. Our novel design can eliminate the preservative induced toxicity from eyedrops thereby impacting hundreds of millions of patients with chronic ophthalmic diseases such as glaucoma and dry eyes. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. [A case of ophthalmic artery occlusion following injection of hyaluronic acid into the glabellar area].

    Science.gov (United States)

    Nonomura, Sakiko; Oshitari, Toshiyuki; Miura, Gen; Chiba, Akihiro; Yamamoto, Shuichi

    2014-09-01

    We report a case of unilateral blindness due to ophthalmic artery occlusion following injection of hyaluronic acid into the glabellar area for facial soft-tissue augmentation. A 20-year old woman underwent injection of hyaluronic acid into the glabellar area at an aesthetic plastic clinic. Immediately after injection, she suffered nausea, pain, paralysis of limbs and visual loss in her right eye. Hyaluronidase was instanly injected into the same place, but these symptoms did not improve. She was transferred to our hospital's emergency department. At the first examination, she had no light perception in the right eye and her right pupil was dilated. The fundus examination revealed right central artery occlusion. No significant findings were detected in her head. Eye ball massage, hyperbaric oxygen therapy, and drip infusion of urokinase were conducted, but no improvement resulted. Fluorescein and indocyanine green angiography showed no filling of the right retinal and choroidal arteries. Electroretinogram was completely disappeared. Magnetic resonance angiography could not reveal the obstruction point of the ophthalmic artery. Ophthalmic artery occlusion was believed to have occured after injection of hyaluronic acid into the glabellar area.

  11. [Randomized parallel group study of 0.0015% tafluprost ophthalmic solution in patients with primary open-angle glaucoma or ocular hypertension (comparison with 0.005% latanoprost ophthalmic solution)].

    Science.gov (United States)

    Ge, Jian; Li, Xiaoxin; Sun, Xinghuai; He, Xiangge; Zhang, Hong

    2015-02-01

    To confirm the non-inferiority of the IOP-lowering effect of the 0.0015% Tafluprost ophthalmic solution to the 0.005% Latanoprost ophthalmic solution in patients with primary open-angle glaucoma or ocular hypertension.Safety was also compared between two groups. This study was conducted from August 2008 to December 2009, at five clinical trial sites in China. Patients of this study population was diagnosed with primary open-angle glaucoma or ocular hypertension in both eyes.Subjects were randomized into 0.0015% Tafluprost group or 0.005% Latanoprost group.Intraocular pressure (IOP) measurement by Goldmann applanation tonometer, slit-lamp microscopy, Gonioscopy, Fundascopy, Visual acuity test, Perimetry, Blood pressure and pulse rate, Subjective symptoms were compered between two groups at Week 0, Week 2 and Week 4.For main effectiveness evaluation index adopt the bad effect evaluation, safety evaluation index by Fisher's exact test probability method. The 246 subjects/246 eyes were randomized (Tafluprost group:122 subjects/122 eyes, Latanoprost group:124 subjects/ 124 eyes). Change in the IOP at 17:00 of Week 2 is (8.8 ± 3.8) mmHg and (8.9 ± 4.4) mmHg (1 mmHg = 0.133 kPa) in Tafluprost group and Latanoprost group. Percent change in the IOP at 17:00 of Week 2 is (33.2 ± 12.8)% and (34.4 ± 14.1)% in Tafluprost group and Latanoprost group. Change in the IOP at 17:00 at the end of treatment is (9.8 ± 4.0) mmHg and (9.2 ± 4.1) mmHg in Tafluprost group and Latanoprost group. Percent change in the IOP at 17:00 at the end of treatment is 37.2% ± 13.4% group and 35.7% ± 13.0% in Tafluprost and Latanoprost group.In addition, distribution of subjects with percentage decrease of IOP > 30% was 72.5% in Tafluprost group higher than 63.8% in Latanoprost group. The major adverse reactions were conjunctival hyperemia, eye irritation, eye pain and foreign body sensation. The incidence of adverse reactions is 31.7% in Tafluprost group and 20.8% in Latanoprost group. The inter

  12. Progesterone increases resistance of ophthalmic and central retinal arteries in climacteric women.

    Science.gov (United States)

    Souza, M A M De; Souza, B M De; Geber, S

    2013-04-01

    To evaluate the effect of a synthetic progestin on the vascular resistance of the ophthalmic and central retinal arteries in climacteric women, compared to placebo, using transorbital ultrasound with Doppler velocimetry. We performed a prospective, randomized, double-blinded, placebo-controlled study with 216 climacteric women. Subjects were randomly allocated to one of two groups: either the group receiving placebo (one pill/day for 30 days) (n = 108) or the group receiving progestin (5 mg medroxyprogesterone acetate/day for 30 days) (n = 108). Transorbital Doppler velocimetric ultrasound was performed, before and after treatment; we measured the pulsatility index, resistance index and systole/diastole ratio. The mean ages of the participants in the study group and the control group were 54 ± 6.2 years (range 48-59 years) and 55 ± 6.8 years (range 46-60 years), respectively. When we compared the effect of the progestin on the central retinal artery before and after treatment, we observed a significant increase after the treatment in all Doppler indices. The same was observed when we compared the effect of the progestin on the ophthalmic artery. In the group of women receiving placebo, the Doppler indices were similar before and after treatment. Our results demonstrate the existence of a progestogenic vasoconstrictive effect in the ophthalmic and central retinal arteries. As this study provides new data, the observed effect needs further investigations to better elucidate its extent. Moreover, our findings may be particularly useful to others interested in understanding the vascular dynamics of the cerebral vessels and to researchers running clinical trials related to hormone replacement therapy.

  13. 21 CFR 524.1662b - Oxytetracycline hydrochloride, polymyxin B sulfate ophthalmic ointment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride, polymyxin B sulfate... DOSAGE FORM NEW ANIMAL DRUGS § 524.1662b Oxytetracycline hydrochloride, polymyxin B sulfate ophthalmic ointment. (a) Specifications. Each gram of the ointment contains oxytetracycline hydrochloride equivalent...

  14. Association between Ophthalmic Timolol and Hospitalisation for Bradycardia

    Directory of Open Access Journals (Sweden)

    Nicole L. Pratt

    2015-01-01

    Full Text Available Introduction. Ophthalmic timolol, a topical nonselective beta-blocker, has the potential to be absorbed systemically which may cause adverse cardiovascular effects. This study was conducted to determine whether initiation of ophthalmic timolol was associated with an increased risk of hospitalisation for bradycardia. Materials and Methods. A self-controlled case-series study was undertaken in patients who were hospitalised for bradycardia and were exposed to timolol. Person-time after timolol initiation was partitioned into risk periods: 1–30 days, 31–180 days, and >180 days. A 30-day risk period prior to initiating timolol was also included. All remaining time was considered unexposed. Results. There were 6,373 patients with at least one hospitalisation for bradycardia during the study period; 267 were exposed to timolol. Risk of bradycardia was significantly increased in the 31–180 days after timolol initiation (incidence rate ratio (IRR = 1.93; 95% confidence interval (CI 1.00–1.87. No increased risk was observed in the first 30 days or beyond 180 days of continuous exposure (IRR = 1.40; 95% CI 0.87–2.26 and IRR = 1.21; 95% CI 0.64–2.31, resp.. Conclusion. Bradycardia is a potential adverse event following timolol initiation. Practitioners should consider patient history before choosing a glaucoma regime and closely monitor patients after treatment initiation with topical nonselective beta-blocker eye drops.

  15. Mydriatics release from solid and semi-solid ophthalmic formulations using different in vitro methods.

    Science.gov (United States)

    Pescina, Silvia; Macaluso, Claudio; Gioia, Gloria Antonia; Padula, Cristina; Santi, Patrizia; Nicoli, Sara

    2017-09-01

    The aim of the present paper was the development of semi-solid (hydrogels) and solid (film) ophthalmic formulations for the controlled release of two mydriatics: phenylephrine and tropicamide. The formulations - based on polyvinylalcohol and hyaluronic acid - were characterized, and release studies were performed with three different in vitro set-ups, i.e. Franz-type diffusion cell, vial method and inclined plane; for comparison, a solution and a commercial insert, both clinically used to induce mydriasis, were evaluated. Both gels and film allowed for a controlled release of drugs, appearing a useful alternative for mydriatics administration. However, the release kinetic was significantly influenced by the method used, highlighting the need for optimization and standardization of in vitro models for the evaluation of drug release from ophthalmic dosage forms.

  16. Clinical utility of 3% diquafosol ophthalmic solution in the treatment of dry eyes

    Directory of Open Access Journals (Sweden)

    Koh S

    2015-05-01

    Full Text Available Shizuka Koh Department of Ophthalmology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan Abstract: Diquafosol is a drug used for dry eye treatment with a novel mechanism of action. It stimulates the secretion of tear fluid and mucin on the ocular surface, thus enabling us to selectively treat the tear film layer, playing an important role in the establishment of the concept of “Tear Film Oriented Therapy (TFOT”, an effective therapeutic approach to dry eye in Japan. The 3% diquafosol ophthalmic solution has been widely used for the treatment of dry eye in clinical practice, and it is currently available in Japan and South Korea. This review provides an overview of the clinical utility of 3% diquafosol ophthalmic solution, focusing on the results of clinical studies on various types of dry eye, including aqueous-deficient dry eye, short tear film breakup time-type dry eye, and post dry eye after laser in situ keratomileusis. It also introduces the additive effect of diquafosol on sodium hyaluronate monotherapy for dry eye, and the effect of 3% diquafosol ophthalmic solution for dry eye-related conditions. Additionally, it summarizes the ocular effects of diquafosol in healthy human eyes. Lastly, the importance of improving tear film stability in dry eye treatment, as well as general advances in dry eye treatments, are described. Keywords: diquafosol, dry eye, mucin secretion, fluid secretion, ocular surface, vision

  17. Laser tissue welding in ophthalmic surgery.

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Ratto, Fulvio; Menabuoni, Luca; Lenzetti, Ivo; Pini, Roberto

    2008-09-01

    Laser welding of ocular tissues is an alternative technique or adjunct to conventional suturing in ophthalmic surgery. It is based on the photothermal interaction of laser light with the main components of the extracellular matrix of connective tissues. The advantages of the welding procedure with respect to standard suturing and stapling are reduced operation times, lesser inflammation, faster healing and increased ability to induce tissue regeneration. The procedure we set up is based on the use of an infrared diode laser in association with the topical application of the chromophore Indocyanine Green. Laser light may be delivered either continuously or in pulses, thus identifying two different techniques that have been applied clinically in various types of transplants of the cornea.

  18. Ophthalmic compensation of visual ametropia based on a programmable diffractive lens

    Science.gov (United States)

    Millán, Maria S.; Pérez-Cabré, Elisabet; Romero, Lenny A.; Ramírez, Natalia

    2013-11-01

    Pixelated liquid crystal displays have been widely used as spatial light modulators to implement programmable diffractive optical elements (DOEs), particularly diffractive lenses. Many different applications of such components have been developed in information optics and optical processors that take advantage of their properties of great flexibility, easy and fast refreshment, and multiplexing capability in comparison with equivalent conventional refractive lenses. In this paper, we explore the application of programmable diffractive lenses displayed on the pixelated screen of a liquid crystal on silicon spatial light modulator (LCoS-SLM) to ophthalmic optics. In particular, we consider the use of programmable diffractive lenses for the visual compensation of some refractive errors (myopia, hyperopia). The theoretical principles of compensation are described and sketched using geometrical optics and paraxial ray tracing. A series of experiments with artificial eye in optical bench are conducted to analyze the compensation accuracy in terms of optical power and to compare the results with those obtained by means of conventional ophthalmic lenses. Practical considerations oriented to feasible applications are provided.

  19. Endovascular Treatment of Persistent Epistaxis due to Pseudoaneurysm Formation of the Ophthalmic Artery Secondary to Nasogastric Tube

    Energy Technology Data Exchange (ETDEWEB)

    Selcuk, Hakan, E-mail: hakanselcuk73@yahoo.com; Soylu, Nur; Albayram, Sait; Selcuk, Dogan; Ozer, Harun; Kocer, Naci; Islak, Civan [Cerrahpasa Medical School, Istanbul University, Department of Radiology, Division of Neuroradiology (Turkey)

    2005-04-15

    We present the case of a 60-year-old man with persistent epistaxis for 20 days that had started 2 weeks after removal of a nasogastric tube placed for an abdominal operation. There was no pathologic finding at selective facial and internal maxillary artery injections. An injury to the ethmoidal branches of the ophthalmic arteries or other arterial origins of bleeding was suspected. The internal carotid artery angiography revealed a pseudoaneurysm of an anterior ethmoidal branch of the left ophthalmic artery. The pseudoaneurysm was occluded with NBCA-histoacryl (25%) injection.

  20. Endovascular Treatment of Persistent Epistaxis due to Pseudoaneurysm Formation of the Ophthalmic Artery Secondary to Nasogastric Tube

    International Nuclear Information System (INIS)

    Selcuk, Hakan; Soylu, Nur; Albayram, Sait; Selcuk, Dogan; Ozer, Harun; Kocer, Naci; Islak, Civan

    2005-01-01

    We present the case of a 60-year-old man with persistent epistaxis for 20 days that had started 2 weeks after removal of a nasogastric tube placed for an abdominal operation. There was no pathologic finding at selective facial and internal maxillary artery injections. An injury to the ethmoidal branches of the ophthalmic arteries or other arterial origins of bleeding was suspected. The internal carotid artery angiography revealed a pseudoaneurysm of an anterior ethmoidal branch of the left ophthalmic artery. The pseudoaneurysm was occluded with NBCA-histoacryl (25%) injection

  1. Efficacy and safety of diquafosol ophthalmic solution in patients with dry eye syndrome: a Japanese phase 2 clinical trial.

    Science.gov (United States)

    Matsumoto, Yukihiro; Ohashi, Yuichi; Watanabe, Hitoshi; Tsubota, Kazuo

    2012-10-01

    To investigate the dose-dependent efficacy and safety of diquafosol ophthalmic solution for the treatment of dry eye syndrome. Randomized, double-masked, multicenter, parallel-group, placebo-controlled trial. A total of 286 Japanese patients with dry eye who were prescribed topical diquafosol (1%, n = 96; 3%, n = 96) or placebo ophthalmic solution (n = 94). After a washout period of 2 weeks, qualified subjects were randomized to receive a single drop of 1% or 3% diquafosol or placebo ophthalmic solutions 6 times per day for 6 weeks. The primary outcome measure was fluorescein corneal staining score assessment. The secondary outcome measures were Rose Bengal corneal and conjunctival staining scores, tear break-up time (BUT), and subjective symptom assessment. Safety measures were clinical blood and urine examination and recording of adverse events. Fluorescein corneal staining scores significantly improved with both 1% and 3% topical diquafosol compared with placebo at 4 weeks, respectively (P = 0.037, P = 0.002). There was a dose-dependent effect among the groups. Rose Bengal corneal and conjunctival staining scores also improved significantly with both 1% and 3% diquafosol compared with placebo (P = 0.007 and P = 0.004, respectively). Subjective dry eye symptom scores significantly improved with both diquafosol ophthalmic solutions (P ≤ 0.033), although there were no significant differences in BUT compared with placebo. No significant differences between the treatment groups were observed in relation to the occurrence of adverse events. Both 1% and 3% diquafosol ophthalmic solutions are considered effective and safe for the treatment of dry eye syndrome. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  2. Scientific publications in ophthalmic journals from China and other top-ranking countries: a 12-year review of the literature.

    Science.gov (United States)

    Huang, Wenbin; Wang, Wei; Zhan, Jiao; Zhou, Minwen; Chen, Shida; Zhang, Xiulan

    2013-06-26

    Eye diseases with increasing mortality are common health problems that affect people of all ages and demographic backgrounds. In this study, we study the publication characteristics in international ophthalmic journals of the US, the UK, Germany, Australia, Japan, and China. Articles published in 53 ophthalmic journals from 2000 to 2011 were retrieved from the PubMed database. We recorded the number of articles published each year, analyzed the publication type, and evaluated the accumulated and average impact factors (IFs), and the distribution of articles in ophthalmic journals in relation to IFs. The characteristics of publication outputs from China and other top-ranking countries were compared. The total number of articles increased significantly during the past 12 years, with an increase of 51.0%. The growth in the annual number of articles from the US, the UK, Australia, and China showed a significantly positive trend. Publications from the US exceeded those from any other country and had the highest IFs, largest number of total citations of articles, and the most articles published in leading ophthalmic journals. During the past 12 years, China contributed 3.5% of the total publications, and the number of Chinese articles showed a more than 6-fold increase (from 99 to 605, R2 =0.947, P<0.001). The numbers of IFs and citations of articles originating in China were mostly lower than for other top-ranking counties. Research on ophthalmic journals has maintained an upward growing trend from 2000 to 2011. Chinese ophthalmology research has developed rapidly, but the gap still exists between China and other top-ranking countries for the advanced level of research.

  3. Immediate Effects of 3% Diquafosol and 0.1% Hyaluronic Acid Ophthalmic Solution on Tear Break-Up Time in Normal Human Eyes.

    Science.gov (United States)

    Nam, Ki Tae; Ahn, So Min; Eom, Youngsub; Kim, Hyo Myung; Song, Jong Suk

    2015-12-01

    The purpose of this study was to evaluate the immediate effect of 3% diquafosol ophthalmic solution on tear break-up time (TBUT) in normal human eyes, and to compare it with that of saline and 0.1% hyaluronate ophthalmic solution. Cross sectional comparative study in the first study, 10 healthy volunteers underwent topical application of 2 different ophthalmic solutions in each eye. Saline was randomly applied to one eye and 3% diquafosol ophthalmic solution was added to the fellow eye. TBUT was measured and video recorded before application and at 5, 10, 15, and 20 min after. The TBUT in each eye was compared at each time point with regard to the 2 different ophthalmic solutions. In the second study, another 10 healthy volunteers were included. The same methods were used to compare the immediate effects of 0.1% hyaluronate and 3% diquafosol ophthalmic solution application on TBUT. In the first study, topical instillation of saline did not increase TBUT. However, 3% diquafosol significantly increased TBUT for up to 15 min after application. At every time point, the TBUT increased more significantly from baseline in the diquafosol group than it did in the saline group. In the second study, 0.1% hyaluronate increased TBUT for up to 5 min after application, while 3% diquafosol increased TBUT for up to 15 min. Although the TBUT changes after 5 min were not significantly different between the 2 groups, the TBUT changes at 10, 15, and 20 min were significantly greater in the 3% diquafosol group than they were in the 0.1% hyaluronic acid group (+1.58 ± 0.82 vs. +0.53 ± 1.36 at 10 min, +0.67 ± 0.91 vs. -0.04 ± 1.29 at 15 min, and -0.06 ± 0.96 vs. -0.59 ± 0.90, diquafosol group vs. hyaluronic acid group). One drop of 3% diquafosol increased TBUT for up to 15 min after application. The immediate effect of 3% diquafosol on TBUT was greater than that of saline and even that of 1% hyaluronate ophthalmic solution.

  4. Formulation and process factors influencing product quality and in vitro performance of ophthalmic ointments.

    Science.gov (United States)

    Xu, Xiaoming; Al-Ghabeish, Manar; Rahman, Ziyaur; Krishnaiah, Yellela S R; Yerlikaya, Firat; Yang, Yang; Manda, Prashanth; Hunt, Robert L; Khan, Mansoor A

    2015-09-30

    Owing to its unique anatomical and physiological functions, ocular surface presents special challenges for both design and performance evaluation of the ophthalmic ointment drug products formulated with a variety of bases. The current investigation was carried out to understand and identify the appropriate in vitro methods suitable for quality and performance evaluation of ophthalmic ointment, and to study the effect of formulation and process variables on its critical quality attributes (CQA). The evaluated critical formulation variables include API initial size, drug percentage, and mineral oil percentage while the critical process parameters include mixing rate, temperature, time and cooling rate. The investigated quality and performance attributes include drug assay, content uniformity, API particle size in ointment, rheological characteristics, in vitro drug release and in vitro transcorneal drug permeation. Using design of experiments (DoE) as well as a novel principle component analysis approach, five of the quality and performance attributes (API particle size, storage modulus of ointment, high shear viscosity of ointment, in vitro drug release constant and in vitro transcorneal drug permeation rate constant) were found to be highly influenced by the formulation, in particular the strength of API, and to a lesser degree by processing variables. Correlating the ocular physiology with the physicochemical characteristics of acyclovir ophthalmic ointment suggested that in vitro quality metrics could be a valuable predictor of its in vivo performance. Published by Elsevier B.V.

  5. Application of ophthalmic ultrasonographyin DR

    Directory of Open Access Journals (Sweden)

    Ya-Ke Li

    2018-02-01

    Full Text Available AIM: To investigate the value of ultrasonography in diabetic retinopathy(DR. METHODS: Totally 103 cases(103 eyesof type 2 diabetes mellitus were selected from May 2015 to May 2017 in our hospital, there were 32 patients 32 eyes with non diabetic retinopathy(NDR, 40 patients 40 eyes with non proliferative diabetic retinopathy(NPDR, and 31 patients 31 eyes with proliferative diabetic retinopathy(PDR, 40 healthy volunteers(40 eyeswere selected as control group, the maximum systolic blood flow velocity(PSV, end diastolic velocity(EDVand resistance index(RIof the central retinal artery(CRA, posterior ciliary artery(PCAand ophthalmic artery(OAwere detected by color Doppler ultrasound. RESULTS: The difference of PSV, EDV and RI of CRA, PCA and OA in each group was statistically significant(PPPPCONCLUSION: Color Doppler ultrasound monitoring the hemodynamic changes of ocular blood vessels in diabetes can provide evidence for early detection of diabetic retinopathy.

  6. Integrated analysis of three bacterial conjunctivitis trials of besifloxacin ophthalmic suspension, 0.6%: microbiological eradication outcomes

    Directory of Open Access Journals (Sweden)

    Morris TW

    2011-09-01

    Full Text Available Timothy W Morris1, Lynne S Gearinger1, Dale W Usner2, Michael R Paterno2, Heleen H DeCory3, Timothy L Comstock3, Wolfgang Haas11Microbiology and Sterilization Sciences, 2Clinical Affairs, 3Global Pharmaceutical Medical Affairs, Bausch & Lomb, Rochester, NY, USAPurpose: To assess clinical antimicrobial efficacy results obtained with besifloxacin ophthalmic suspension, 0.6%, administered three times a day (TID for 5 days, integrated across three clinical trials of bacterial conjunctivitis and to investigate any microbiological eradication failures.Methods: Clinical microbiological eradication data from three randomized, double-masked, parallel group studies of patients with bacterial conjunctivitis (two vehicle controlled; one active controlled with moxifloxacin ophthalmic solution, 0.5% were integrated. All bacterial samples isolated at baseline above the species-specific threshold value were subjected to antimicrobial susceptibility testing. Samples isolated at subsequent visits were subjected to susceptibility testing and pulsed-field gel electrophoresis (PFGE to investigate the cause of eradication failures and the potential for drug resistance development.Results: Visit 2 (day 4 or 5 and visit 3 (day 8 overall microbiological eradication rates were 92.2% and 88.4% for besifloxacin ophthalmic suspension compared with 61.4% and 72.5% for vehicle and 91.6% and 85.7% for moxifloxacin ophthalmic solution. Visit 2 and visit 3 microbiological eradication rates for Gram-positive and Gram-negative isolates and for individual species were consistent with the overall eradication rates. The majority of observed eradication failures in any treatment group were due to the persistence of the pathogen isolated at baseline. Eradication failures in the besifloxacin treatment group were not associated with lower antimicrobial susceptibility at baseline. PFGE data showed that the majority of bacterial strains in eyes with eradication failures were identical to

  7. Neuro-ophthalmic and clinical characteristics of brain tumours in a tertiary hospital in Ghana

    International Nuclear Information System (INIS)

    Tagoe, N. N.; Essuman, V. A.; Fordjuor, G.; Akpalu, J.; Bankah, P.; Ndanu, T.

    2015-01-01

    Anecdotally, increasing number of patients are seen at Korle Bu Teaching Hospital (KBTH) with brain tumour. Neuro-ophthalmic symptoms and signs may help in timely diagnosis and intervention. The objective of this study is to evaluate the neuro-ophthalmic and clinical characteristics of brain tumour in patients presenting at a tertiary hospital in Ghana. The study design involved a prospective case series involving 36 consecutive patients newly diagnosed with brain tumour from November 2010 to October 2011, at the Ophthalmology, Neurosurgery and Endocrine units of KBTH, Ghana. All patients had clinical diagnosis of brain tumour with confirmation by computerized tomography (CT) or magnetic resonance imaging (MRI). Thirteen patients had histological confirmation of diagnosis. The outcome measures of the study include presenting visual acuity, colour vision, visual fields and cranial nerve deficits. Data of 36 patients were analysed. The results of the study showed that ages ranged from 3 to 69 years, mean (SD) 42.56(±16.6 years). Twenty-six (72%) were females. Tumours included pituitary adenoma (20, 55.5%), meningioma (10, 27.8%), choroid plexus tumour (1, 2.8%), medulloblastom (1, 2.8%), craniopharyngioma (1, 2.8%), haemangioblastoma (1, 2.8%), thalamic tumour (1, 2.8%) and haemangioma (1, 2.8%). Histologically confirmed tumours included pituitary adenoma (9, 69.2%), meningioma (3, 23.1%), craniopharyngioma (1, 7.7%). One patient had both a pituitary adenoma and meningioma. Blurred vision (30, 83.3%), headache (28, 77.8%) and photophobia (13, 36.1%) were predominant symptoms. Commonest neuro-ophthalmic signs were impaired colour vision (62 eyes, 88.6%), optic atrophy (26, 74.3%), unilateral or bitemporal hemianopia (15, 41.5%) and relative afferent pupillary defect (12, 34.3%). Seven (19.4%) patients were visually impaired and nine (25%) blind. Thirty-three of 72(45.8%) eyes had monocular blindness. Common neuro-ophthalmic characteristics were blurred vision

  8. Determination of permeability coefficients of ophthalmic drugs through different layers of porcine, rabbit and bovine eyes.

    Science.gov (United States)

    Loch, Christian; Zakelj, Simon; Kristl, Albin; Nagel, Stefan; Guthoff, Rudolf; Weitschies, Werner; Seidlitz, Anne

    2012-08-30

    To treat ophthalmic diseases like glaucoma or inflammatory disorders topically applied ophthalmic formulations such as eye drops are usually used. In addition, novel ophthalmic implants releasing drug substances locally into different parts of the eye are available today. In the work presented here, the permeability coefficients of selected drugs (ciprofloxacin hydrochloride, lidocaine hydrochloride, timolol maleate) for ophthalmic tissues were determined using side-by-side diffusion chambers (so-called Ussing chambers). Sclera, conjunctiva, cornea, choroidea-retina-complex and a complex of conjunctiva-sclera-choroidea-retina were excised from fresh porcine, rabbit and bovine eyes. In the porcine eye tissues the highest P(app) values were obtained for conjunctiva with the exception of lidocaine. Therefore, it can be estimated that a certain amount of drug diffuses or is transported through conjunctiva after application. The P(app) values for sclera were also higher than those for cornea and even more, the surface area of sclera which is available for drug absorption is much larger than that of cornea when applying an implant. The obtained permeability coefficients for sclera and conjunctiva indicate that the administration of periocular implants can be an alternative to topically applied formulations. The complexes of the tissues were a significantly (p<0.01) stronger barrier to the investigated substances than the separated tissues. Distinct differences in permeability coefficients between the investigated animal tissues were observed. Overall the highest P(app) values for all mounted tissues were obtained with the rabbit, followed by porcine and bovine eyes. Because of these distinct interspecies differences one must be very careful when selecting the proper animal model for the permeability experiments. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Correlation of ophthalmic examination with carrier status in females potentially harboring a severe Norrie disease gene mutation.

    Science.gov (United States)

    Khan, Arif O; Aldahmesh, Mohammed A; Meyer, Brian

    2008-04-01

    To correlate ophthalmic findings with carrier status for a severe Norrie disease (ND) gene mutation (C95F). Prospective interventional case series. Six potential carriers and 1 obligate carrier from a family harboring the mutation. An ophthalmologist blind to the pedigree performed a full ophthalmic examination for the 7 asymptomatic family members. A peripheral blood sample was collected from each for ND gene sequencing. Ophthalmic examination findings (with attention to the presence or absence of retinal findings) and results of ND gene sequencing. Three carriers were identified by molecular genetics, and all 3 of them had peripheral retinal abnormality. However, 3 of the 4 genetically identified noncarriers also exhibited peripheral retinal abnormality. Two of these noncarriers with retinal findings were the offspring of a confirmed noncarrier. The genetically identified noncarrier with a normal peripheral retinal examination was the daughter of an obligate carrier. The presence of peripheral retinal changes was not useful for carrier prediction in a family harboring ND. There are likely additional loci responsible for phenotypic expression.

  10. Efficacy and safety of fixed-combination bimatoprost/timolol ophthalmic solution

    OpenAIRE

    Moon, Suk Bae; Han, Sang Beom

    2017-01-01

    Suk Bae Moon,1 Sang Beom Han21Department of Surgery, Kangwon National University Hospital, Kangwon National University Graduate School of Medicine, Chuncheon, Korea, 2Department of Ophthalmology, Kangwon National University Hospital, Kangwon National University Graduate School of Medicine, Chuncheon, KoreaWe read, with interest, the article by Sun et al1 entitled “Patient satisfaction with fixed-combination bimatoprost/timolol ophthalmic solution: a survey study in patients with gla...

  11. Ophthalmic acid accumulation in an Escherichia coli mutant lacking the conserved pyridoxal 5'-phosphate-binding protein YggS.

    Science.gov (United States)

    Ito, Tomokazu; Yamauchi, Ayako; Hemmi, Hisashi; Yoshimura, Tohru

    2016-12-01

    Escherichia coli YggS is a highly conserved pyridoxal 5'-phosphate (PLP)-binding protein whose biochemical function is currently unknown. A previous study with a yggS-deficient E. coli strain (ΔyggS) demonstrated that YggS controls l-Ile- and l-Val-metabolism by modulating 2-ketobutyrate (2-KB), l-2-aminobutyrate (l-2-AB), and/or coenzyme A (CoA) availability in a PLP-dependent fashion. In this study, we found that ΔyggS accumulates an unknown metabolite as judged by amino acid analyses. LC/MS and MS/MS analyses of the compound with propyl chloroformate derivatization, and co-chromatography analysis identified this compound as γ-l-glutamyl-l-2-aminobutyryl-glycine (ophthalmic acid), a glutathione (GSH) analogue in which the l-Cys moiety is replaced by l-2-AB. We also determine the metabolic consequence of the yggS mutation. Absence of YggS initially increases l-2-AB availability, and then causes ophthalmic acid accumulation and CoA limitation in the cell. The expression of a γ-glutamylcysteine synthetase and a glutathione synthetase in a ΔyggS background causes high-level accumulation of ophthalmic acid in the cells (∼1.2 nmol/mg cells) in a minimal synthetic medium. This opens the possibility of a first fermentative production of ophthalmic acid. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  12. 76 FR 81806 - Ophthalmic and Topical Dosage Form New Animal Drugs; Ivermectin Topical Solution

    Science.gov (United States)

    2011-12-29

    .... FDA-2011-N-0003] Ophthalmic and Topical Dosage Form New Animal Drugs; Ivermectin Topical Solution... solution of ivermectin. DATES: This rule is effective December 29, 2011. FOR FURTHER INFORMATION CONTACT... ANADA 200-318 for [[Page 81807

  13. The ocular distribution of 14C-labeled bromfenac ophthalmic solution 0.07% in a rabbit model

    Directory of Open Access Journals (Sweden)

    Baklayan GA

    2014-09-01

    Full Text Available George A Baklayan, Mauricio Muñoz Bausch + Lomb, Irvine, CA, USA Purpose: To evaluate the ocular distribution of an advanced formulation of bromfenac ophthalmic solution. Two studies were conducted in rabbits: 1 a 12-hour parallel-group study comparing the ocular distribution of 14C-bromfenac ophthalmic solution 0.07%, pH 7.8 with that of 14C-bromfenac ophthalmic solution 0.09%, pH 8.3, and 2 a 24-hour study evaluating the ocular distribution of 14C-bromfenac ophthalmic solution 0.07%, pH 7.8.Methods: In the 12-hour study, rabbits were randomized to receive 50 µL of 14C-bromfenac 0.07%, pH 7.8 or 50 µL 14C-bromfenac 0.09%, pH 8.3 in one eye, whereas, in the 24-hour, study both eyes received 50 µL of 14C-bromfenac 0.07%, pH 7.8. Ocular tissues were collected at 1, 2, 4, 8, 12 (both studies and 24 hours (second study only following drug instillation, and tissue radioactivity was determined using liquid scintillation chromatography. Results: Measureable levels of bromfenac were observed in all ocular tissues, with the exception of vitreous humor, regardless of formulation. In the 12-hour study, high concentrations of 14C-bromfenac were found in the sclera, followed by the iris/ciliary body, aqueous humor, choroid, retina, and lens. There was no significant difference between the bromfenac 0.07%, pH 7.8 and bromfenac 0.09%, pH 8.3 formulations in any 14C-bromfenac tissue levels at any time point, with the exception of in sclera at 2 hours post-instillation (0.451 µg eq/g versus 0.302 µg eq/g, respectively, P<0.001. There was also no significant difference in the total amount of 14C-bromfenac in the tissues evaluated following instillation of the two formulations. In the 24-hour study evaluating bromfenac 0.07%, pH 7.8 only, high concentrations of 14C-bromfenac were found 1 hour post-instillation in the cornea (2.402 µg eq/g and conjunctiva (1.049 µg eq/g, two tissues not evaluated in the 12-hour study. The rank order of 14C

  14. An ophthalmic solution of a peroxisome proliferator-activated receptor gamma agonist prevents corneal inflammation in a rat alkali burn model.

    Science.gov (United States)

    Uchiyama, Masaaki; Shimizu, Akira; Masuda, Yukinari; Nagasaka, Shinya; Fukuda, Yuh; Takahashi, Hiroshi

    2013-01-01

    We clarified the effects of an ophthalmic solution of a peroxisome proliferator-activated receptor gamma (PPARγ) agonist on corneal inflammation and wound healing after alkali burn injury in rats. After alkali exposure, either an ophthalmic solution with 0.1% pioglitazone hydrochloride (the PPARγ group) or vehicle (the vehicle group) was topically applied to the cornea until day 14. Histological, immunohistochemical, and real-time reverse transcription polymerase chain reaction analysis were performed. After alkali injury, PPARγ expression increased, with the infiltration of many inflammatory cells. The infiltration of neutrophils and macrophages started from the corneal limbus within 6 h, and developed in the corneal center by day 7, with associated neovascularization. The accumulation of α-smooth muscle actin-positive myofibroblasts and the deposition of type III collagen were noted on day 14. The histological changes were suppressed significantly by treatment with the ophthalmic solution of the PPARγ agonist. In addition, the number of infiltrating M2 macrophages in the cornea was increased by PPARγ agonist treatment. In real-time reverse transcription polymerase chain reaction analysis, the messenger ribonucleic acid expression levels of interleukin-1β (IL-1β), IL-6, IL-8, monocyte chemoattractant protein-1, tumor necrosis factor-α, transforming growth factor beta 1, and vascular endothelial growth factor-A were decreased in the PPARγ group compared to the vehicle group in the early periods of corneal inflammation. The ophthalmic solution of the PPARγ agonist inhibited inflammation, decreased the fibrotic reaction, and prevented neovascularization in the cornea from the early phase after alkali burn injury. The ophthalmic solution of the PPARγ agonist may provide a new treatment strategy with useful clinical applications for corneal inflammation and wound healing.

  15. Protective Effect of Tea Polyphenol Ophthalmic Gel on Lens Epithelial Cells in Rabbits with Silicone Oil Tamponade after Vitrectomy

    Directory of Open Access Journals (Sweden)

    Xianzhen Ma

    2014-01-01

    Full Text Available Purpose. The aim of this study was to investigate the effect of tea polyphenols (TP ophthalmic gel on lens epithelial cells (LECs in rabbits with silicone oil tamponade after vitrectomy. Methods. In this study, unilateral vitrectomy with silicone oil tamponade was performed using 2-month-old New Zealand white rabbits (n = 72; meanwhile, age-matched nonoperated rabbits (n = 18 were used as controls. The TP ophthalmic gel was administered topically in the surgical eyes till they were sacrificed. On days 45 and 90 after operation, the levels of reactive oxygen species (ROS, mitochondrial membrane potential (ΔΨm, and apoptosis of LECs were analyzed, respectively. Meanwhile, caspase-3 mRNA and protein levels were also determined. Results. The results indicate that the levels of ROS and apoptosis were elevated for LECs in rabbits after operation, whereas ΔΨm was decreased. Caspase-3 was apparently increased at both mRNA and protein levels. Treatment of TP ophthalmic gel could reduce the generation of ROS, maintain ΔΨm, inhibit the overexpression of caspase-3, and thus decrease the apoptosis of LECs of rabbits after operation. Conclusions. TP ophthalmic gel can efficiently inhibit caspase-3 overexpression, reduce the apoptosis of LECs, and prevent LECs from damage. Our result provides a new approach to prevent the development of complicated cataract after vitrectomy.

  16. Numerical Modeling of Ophthalmic Response to Space

    Science.gov (United States)

    Nelson, E. S.; Myers, J. G.; Mulugeta, L.; Vera, J.; Raykin, J.; Feola, A.; Gleason, R.; Samuels, B.; Ethier, C. R.

    2015-01-01

    To investigate ophthalmic changes in spaceflight, we would like to predict the impact of blood dysregulation and elevated intracranial pressure (ICP) on Intraocular Pressure (IOP). Unlike other physiological systems, there are very few lumped parameter models of the eye. The eye model described here is novel in its inclusion of the human choroid and retrobulbar subarachnoid space (rSAS), which are key elements in investigating the impact of increased ICP and ocular blood volume. Some ingenuity was required in modeling the blood and rSAS compartments due to the lack of quantitative data on essential hydrodynamic quantities, such as net choroidal volume and blood flowrate, inlet and exit pressures, and material properties, such as compliances between compartments.

  17. Moorfields technique of donor cornea mounting for femtosecond-assisted keratoplasty: use of viscoelastic in the artificial anterior chamber.

    Science.gov (United States)

    Iovieno, Alfonso; Chowdhury, Vivek; Stevens, Julian D; Maurino, Vincenzo

    2012-07-01

    Appropriate mounting and cutting of the donor sclero-corneal cap is often cumbersome during femtosecond laser-assisted keratoplasty. The authors describe a technique for donor cornea femtosecond laser cutting using ophthalmic viscoelastic devices. The donor sclero-corneal cap is mounted on the artificial anterior chamber using a dispersive ophthalmic viscoelastic device instead of saline solution. The chances of artificial anterior chamber pressure loss, inadequate applanation, and fluid leaks are consistently reduced with the use of dispersive ophthalmic viscoelastic devices. The speed of donor femtosecond laser cutting is increased. The viscosity and elasticity of dispersive ophthalmic viscoelastic devices greatly assist the procedure with regard to ease of applanation, corneal endothelium protection, and decreased distortion of the applanated cornea. Copyright 2012, SLACK Incorporated.

  18. Regulation of vascular tone in rabbit ophthalmic artery: cross talk of endogenous and exogenous gas mediators.

    Science.gov (United States)

    Salomone, Salvatore; Foresti, Roberta; Villari, Ambra; Giurdanella, Giovanni; Drago, Filippo; Bucolo, Claudio

    2014-12-15

    Nitric oxide (NO), carbon monoxide (CO) and hydrogen sulphide (H2S) modulate vascular tone. In view of their therapeutic potential for ocular diseases, we examined the effect of exogenous CO and H2S on tone of isolated rabbit ophthalmic artery and their interaction with endogenous and exogenous NO. Ophthalmic artery segments mounted on a wire myograph were challenged with cumulative concentrations of phenylephrine (PE) in the presence or absence of NG-nitro-L-arginine (LNNA) to inhibit production of NO, the CO-releasing molecules CORMs or the H2S-donor GYY4137. The maximal vasoconstriction elicited by PE reached 20-30% of that induced by KCl but was dramatically increased by incubation with LNNA. GYY4137 significantly raised PE-mediated vasoconstriction, but it did not change the response to PE in the presence of LNNA or the relaxation to sodium nitroprusside (SNP). CORMs concentration-dependently inhibited PE-induced constriction, an effect that was synergistic with endogenous NO (reduced by LNNA), but insensitive to blockade of guanylyl cyclase by 1H-[1,2,4]oxadiazolo[4,3,-α]quinoxalin-1-one (ODQ). In vascular tissues cyclic GMP (cGMP) levels seemed reduced by GYY4137 (not significantly), but were not changed by CORM. These data indicate that CO is able per se to relax isolated ophthalmic artery and to synergize with NO, while H2S counteracts the effect of endogenous NO. CO does not stimulate cGMP production in our system, while H2S may reduce cGMP production stimulated by endogenous NO. These findings provide new insights into the complexities of gas interactions in the control of ophthalmic vascular tone, highlighting potential pharmacological targets for ocular diseases. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Multimodal ophthalmic imaging using handheld spectrally encoded coherence tomography and reflectometry (SECTR)

    Science.gov (United States)

    Leeburg, Kelsey C.; El-Haddad, Mohamed T.; Malone, Joseph D.; Terrones, Benjamin D.; Tao, Yuankai K.

    2018-02-01

    Scanning laser ophthalmoscopy (SLO) provides high-speed, noninvasive en face imaging of the retinal fundus. Optical coherence tomography (OCT) is the current "gold-standard" for ophthalmic diagnostic imaging and enables depth-resolved visualization of ophthalmic structures and image-based surrogate biomarkers of disease. We present a compact optical and mechanical design for handheld spectrally encoded coherence tomography and reflectometry (SECTR) for multimodality en face spectrally encoded reflectometry (SER) and cross-sectional OCT imaging. We custom-designed a double-pass telecentric scan lens, which halves the size of 4-f optical relays and allowed us to reduce the footprint of our SECTR scan-head by a factor of >2.7x (volume) over our previous design. The double-pass scan lens was optimized for diffraction-limited performance over a +/-10° scan field. SECTR optics and optomechanics were combined in a compact rapid-prototyped enclosure with dimensions 87 x 141.8 x 137 mm (w x h x d). SECTR was implemented using a custom-built 400 kHz 1050 nm swept-source. OCT and SER were simultaneously digitized on dual input channels of a 4 GS/s digitizer at 1.4 GS/s per channel. In vivo human en face SER and cross-sectional OCT images were acquired at 350 fps. OCT volumes of 1000 B-scans were acquired in 2.86 s. We believe clinical translation of our compact handheld design will benefit point-of-care ophthalmic diagnostics in patients who are unable to be imaged on conventional slit-lamp based systems, such as infants and the bedridden. When combined with multi-volumetric registration methods, handheld SECTR will have advantages in motion-artifact free imaging over existing handheld technologies.

  20. 21 CFR 886.1750 - Skiascopic rack.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skiascopic rack. 886.1750 Section 886.1750 Food... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1750 Skiascopic rack. (a) Identification. A skiascopic rack is a device that is a rack and a set of attached ophthalmic lenses of various dioptric strengths...

  1. An ophthalmic solution of a peroxisome proliferator-activated receptor gamma agonist prevents corneal inflammation in a rat alkali burn model

    Science.gov (United States)

    Uchiyama, Masaaki; Masuda, Yukinari; Nagasaka, Shinya; Fukuda, Yuh; Takahashi, Hiroshi

    2013-01-01

    Purpose We clarified the effects of an ophthalmic solution of a peroxisome proliferator-activated receptor gamma (PPARγ) agonist on corneal inflammation and wound healing after alkali burn injury in rats. Methods After alkali exposure, either an ophthalmic solution with 0.1% pioglitazone hydrochloride (the PPARγ group) or vehicle (the vehicle group) was topically applied to the cornea until day 14. Histological, immunohistochemical, and real-time reverse transcription polymerase chain reaction analysis were performed. Results After alkali injury, PPARγ expression increased, with the infiltration of many inflammatory cells. The infiltration of neutrophils and macrophages started from the corneal limbus within 6 h, and developed in the corneal center by day 7, with associated neovascularization. The accumulation of α-smooth muscle actin-positive myofibroblasts and the deposition of type III collagen were noted on day 14. The histological changes were suppressed significantly by treatment with the ophthalmic solution of the PPARγ agonist. In addition, the number of infiltrating M2 macrophages in the cornea was increased by PPARγ agonist treatment. In real-time reverse transcription polymerase chain reaction analysis, the messenger ribonucleic acid expression levels of interleukin-1β (IL-1β), IL-6, IL-8, monocyte chemoattractant protein-1, tumor necrosis factor-α, transforming growth factor beta 1, and vascular endothelial growth factor-A were decreased in the PPARγ group compared to the vehicle group in the early periods of corneal inflammation. Conclusions The ophthalmic solution of the PPARγ agonist inhibited inflammation, decreased the fibrotic reaction, and prevented neovascularization in the cornea from the early phase after alkali burn injury. The ophthalmic solution of the PPARγ agonist may provide a new treatment strategy with useful clinical applications for corneal inflammation and wound healing. PMID:24194635

  2. Time Course of Prostaglandin Analog-related Conjunctival Hyperemia and the Effect of a Nonsteroidal Anti-inflammatory Ophthalmic Solution.

    Science.gov (United States)

    Sakata, Rei; Sakisaka, Toshihiro; Matsuo, Hiroshi; Miyata, Kazunori; Aihara, Makoto

    2016-03-01

    It is reported that nonsteroidal anti-inflammatory drug (NSAID) ophthalmic solution affected the therapeutic efficacy of prostaglandin (PG) analog by inhibiting endogenous PG production. However, whether NSAID ophthalmic solution interferes with its conjunctival hyperemia is unknown. We investigated the effect of NSAID ophthalmic solution on its hyperemia. This was a prospective, randomized, double-blind, placebo-controlled 1-month trial. Benzalkonium chloride-free travoprost 0.004% was used as a PG analog and administered once daily (08:00) in both eyes. Bromfenac sodium hydrate was assigned randomly to 1 eye twice daily (08:00 and 20:00) (the NSAID side), whereas flavin adenine dinucleotide sodium was applied to the fellow eye of each patient twice daily (08:00 and 20:00) (the control side). Conjunctival photographs of both eyes were taken 3 times (08:00, 14:00, 20:00) on days 1, 2, 7, and 28, and hyperemia was scored from 0 to 5 (H-score). We compared H-scores on the NSAID and control sides. Twenty-eight Japanese normal subjects completed the study. The H-score on the NSAID side was significantly lower than that on the control side on day 1 at 14:00 (P=0.016, paired t test) and day 2 at 14:00 (P=0.016). But there were no differences at 20:00 on each day and after that time. The use of NSAID ophthalmic solution had almost no impact on PG analog-related conjunctival hyperemia. This partly suggests that the action mechanism of endogenous PG after administrating PG analog might be no correlation with conjunctival hyperemia.

  3. An historical ophthalmic study of Jane Austen.

    Science.gov (United States)

    Wilson, Graham A

    2012-11-01

    Today, no other classic novelist has the popularity or power of Jane Austen, and in 2013 the world will celebrate 200 years of her comic masterpiece Pride and Prejudice. Her millions of fans have an abiding fascination with all aspects of her life, including her health and the cause of her death. This historical ophthalmic study of Jane Austen, based on very incomplete medical bibliographic data, finds that she had a mild ocular surface disorder from age 23. This disorder did not significantly impact on her visual performance for writing. There are many references to eyes in her novels, but Jane's eyes and those of her characters cannot contribute further to the debate around the cause of her death at age 41.

  4. The effect of ketamine on the separation anxiety and emergence agitation in children undergoing brief ophthalmic surgery under desflurane general anesthesia

    OpenAIRE

    Jeong, Won Ju; Kim, Woon Young; Moon, Man Gook; Min, Doo Jae; Lee, Yoon Sook; Kim, Jae Hwan; Park, Young Cheol

    2012-01-01

    Background Emergence agitation (EA) frequently occurs after desflurane anesthesia in children. Ketamine, because of its sedative and analgesic properties, might be useful for the management of separation anxiety and EA. We investigated the preventive effect of ketamine on separation anxiety and EA after desflurane anesthesia in children for brief ophthalmic surgery. Methods Sixty children, ranging in age from 2-8 years old, undergoing brief ophthalmic surgery were randomly allocated to one of...

  5. CHECKPOINT INHIBITOR IMMUNE THERAPY: Systemic Indications and Ophthalmic Side Effects.

    Science.gov (United States)

    Dalvin, Lauren A; Shields, Carol L; Orloff, Marlana; Sato, Takami; Shields, Jerry A

    2018-06-01

    To review immune checkpoint inhibitor indications and ophthalmic side effects. A literature review was performed using a PubMed search for publications between 1990 and 2017. Immune checkpoint inhibitors are designed to treat system malignancies by targeting one of three ligands, leading to T-cell activation for attack against malignant cells. These ligands (and targeted drug) include cytotoxic T-lymphocyte antigen-4 (CTLA-4, ipilimumab), programmed death protein 1 (PD-1, pembrolizumab, nivolumab), and programmed death ligand-1 (PD-L1, atezolizumab, avelumab, durvalumab). These medications upregulate the immune system and cause autoimmune-like side effects. Ophthalmic side effects most frequently manifest as uveitis (1%) and dry eye (1-24%). Other side effects include myasthenia gravis (n = 19 reports), inflammatory orbitopathy (n = 11), keratitis (n = 3), cranial nerve palsy (n = 3), optic neuropathy (n = 2), serous retinal detachment (n = 2), extraocular muscle myopathy (n = 1), atypical chorioretinal lesions (n = 1), immune retinopathy (n = 1), and neuroretinitis (n = 1). Most inflammatory side effects are managed with topical or periocular corticosteroids, but advanced cases require systemic corticosteroids and cessation of checkpoint inhibitor therapy. Checkpoint inhibitors enhance the immune system by releasing inhibition on T cells, with risk of autoimmune-like side effects. Ophthalmologists should include immune-related adverse events in their differential when examining cancer patients with new ocular symptoms.

  6. RESULTS OF THE SURVEY CONDUCTED AMONG OPHTHALMOLOGISTS ON THE ISSUE OF EQUIPMENT OF MEDICAL INSTITUTIONS WITH OPHTHALMOLOGY DEVICES

    Directory of Open Access Journals (Sweden)

    S. V. Seraphimov

    2017-01-01

    Full Text Available Introduction. The problem of limited accessibility and quality of ophthalmic medical care remains one of the leading ones in the national healthcare. This article presents results of the survey conducted among ophthalmologists about the effect of large-scale equipment of all medical institutions in the Leningrad Region with modern ophthalmologic devices over the recent years.Objective is to determine the contribution of the health care modernization program to equipping the medical institutions of the Leningrad Region with modern ophthalmologic medical devices, and to identify the main areas for improving the ophthalmologic care for residents of the Leningrad region with cataracts.Materials and methods. According to a specially developed questionnaire, 105 ophthalmologists from the Leningrad Region were interviewed. The survey was conducted among physicians working both in out-patient medical facilities and in medical facilities with in-patient modalities.Results. The results of the study confirmed positive changes that occurred in recent years as a result of equipping medical institutions with modern medical devices. Almost two-thirds (59.9% of respondents noted that equipping with modern medical devices had a significant impact on the quality of the medical and diagnostic measures carried out in healthcare facilities of the region.Conclusions. The equipment had a significant impact on the diagnosis and treatment of all kinds of diseases of the eye and its appendages, especially such eye disease which is so common among the population of the Leningrad Region as cataracts (75.0 per 100 ophthalmologists surveyed. At the same time, in spite of these efforts, the standard for equipping ophthalmologic departments in individual medical institutions has not been fully provided. Only every fifth (20.9% ophthalmologist noted during the survey that the list of available ophthalmic devices was sufficient, and that they all worked properly.

  7. Efficacy and safety of retinol palmitate ophthalmic solution in the treatment of dry eye: a Japanese Phase II clinical trial.

    Science.gov (United States)

    Toshida, Hiroshi; Funaki, Toshinari; Ono, Koichi; Tabuchi, Nobuhito; Watanabe, Sota; Seki, Tamotsu; Otake, Hiroshi; Kato, Takuji; Ebihara, Nobuyuki; Murakami, Akira

    2017-01-01

    The purpose of this study was to investigate the efficacy and safety of the administration of retinol palmitate (VApal) ophthalmic solution (500 IU/mL) for the treatment of patients with dry eye. This study included 66 patients with dry eye. After a 2-week washout period, patients were randomized (1:1) into either a VApal ophthalmic solution or a placebo group, and a single drop of either solution was administered six times daily for 4 weeks. Efficacy measures were 12 subjective symptoms, rose bengal (RB) and fluorescein staining scores, tear film breakup time, and tear secretion. Safety measures included clinical blood and urine analyses and adverse event recordings. In comparisons of the two groups, the mean change in RB staining score from baseline was significantly lower in the VApal group at 2 and 4 weeks ( P ophthalmic solution (500 IU/mL) is safe and effective for the treatment of patients with dry eye.

  8. Effectiveness of ophthalmic solution preservatives: a comparison of latanoprost with 0.02% benzalkonium chloride and travoprost with the sofZia preservative system

    OpenAIRE

    Ryan, Gerard; Fain, Joel M; Lovelace, Cherie; Gelotte, Karl M

    2011-01-01

    Abstract Background Although in vitro and in vivo laboratory studies have suggested that benzalkonium chloride (BAK) in topical ophthalmic solutions may be detrimental to corneal epithelial cells, multiple short- and long-term clinical studies have provided evidence supporting the safety of BAK. Despite the conflicting evidence, BAK is the most commonly used preservative in ophthalmic products largely due to its proven antimicrobial efficacy. This study was designed to characterize the antimi...

  9. Gasserian Ganglion and Retrobulbar Nerve Block in the Treatment of Ophthalmic Postherpetic Neuralgia: A Case Report.

    Science.gov (United States)

    Huang, Jie; Ni, Zhongge; Finch, Philip

    2017-09-01

    Varicella zoster virus reactivation can cause permanent histological changes in the central and peripheral nervous system. Neural inflammatory changes or damage to the dorsal root ganglia sensory nerve fibers during reactivation can lead to postherpetic neuralgia (PHN). For PHN of the first division of the fifth cranial nerve (ophthalmic division of the trigeminal ganglion), there is evidence of inflammatory change in the ganglion and adjacent ocular neural structures. First division trigeminal nerve PHN can prove to be difficult and sometimes even impossible to manage despite the use of a wide range of conservative measures, including anticonvulsant and antidepressant medication. Steroids have been shown to play an important role by suppressing neural inflammatory processes. We therefore chose the trigeminal ganglion as an interventional target for an 88-year-old woman with severe ophthalmic division PHN after she failed to respond to conservative treatment. Under fluoroscopic guidance, a trigeminal ganglion nerve block was performed with lidocaine combined with dexamethasone. A retrobulbar block with lidocaine and triamcinolone settled residual oculodynia. At 1-year follow-up, the patient remained pain free and did not require analgesic medication. To our knowledge, this is the first reported case of ophthalmic division PHN successfully treated with a combination of trigeminal ganglion and retrobulbar nerve block using a local anesthetic agent and steroid for central and peripheral neural inflammatory processes. © 2016 World Institute of Pain.

  10. 75 FR 26647 - Ophthalmic and Topical Dosage Form New Animal Drugs; Ivermectin Topical Solution

    Science.gov (United States)

    2010-05-12

    .... FDA-2010-N-0002] Ophthalmic and Topical Dosage Form New Animal Drugs; Ivermectin Topical Solution... are treated with a topical solution of ivermectin. DATES: This rule is effective May 12, 2010. FOR... ANADA 200-340 for PRIVERMECTIN (ivermectin), a topical solution used on cattle to control infestations...

  11. Systemic absorption and adverse ocular and systemic effects after topical ophthalmic administration of 0.1% diclofenac to healthy cats.

    Science.gov (United States)

    Hsu, Kimberly K; Pinard, Chantale L; Johnson, Ron J; Allen, Dana G; KuKanich, Butch K; Nykamp, Stephanie G

    2015-03-01

    To quantify plasma concentrations and determine adverse ocular, renal, or hepatic effects associated with repeated topical ophthalmic application of 0.1% diclofenac to healthy cats. 8 healthy sexually intact male cats. A randomized, placebo-controlled crossover study was conducted. A topical formulation of 0.1% diclofenac was administered 4 times/d for 7 days to 4 cats, and artificial tear (control) solution was administered to the other 4 cats. After a 12-day washout period, cats received the other treatment. Ophthalmic examinations were performed daily. Plasma samples were obtained on days 1 and 7 for pharmacokinetic analysis. A CBC, serum biochemical analysis, urinalysis, determination of urine protein-to-creatinine ratio, and determination of glomerular filtration rate were performed before the start of the study and after each 7-day treatment period. Mild conjunctival hyperemia was the only adverse ocular effect detected. Maximal drug concentration and area under the curve were significantly higher on day 7 than on day 1. Diclofenac-treated cats had a significantly lower glomerular filtration rate than did control-treated cats after the second but not after the first treatment period, presumably associated with iatrogenic hypovolemia. Topical ophthalmic administration of 0.1% diclofenac was well tolerated in healthy cats, with only mild signs of ocular irritation. Detectable systemic concentrations of diclofenac were achieved with accumulation over 7 days. Systemic absorption of diclofenac may be associated with reduced glomerular filtration rate, particularly in volume-contracted animals. Topical ophthalmic 0.1% diclofenac should be used with caution in volume-contracted or systemically ill cats.

  12. Effectiveness and relevant factors of 2% rebamipide ophthalmic suspension treatment in dry eye.

    Science.gov (United States)

    Ueda, Kaori; Matsumiya, Wataru; Otsuka, Keiko; Maeda, Yoshifumi; Nagai, Takayuki; Nakamura, Makoto

    2015-06-06

    Rebamipide with mucin secretagogue activity was recently approved for the treatment of dry eye. The efficacy and safety in the treatment of rebamipide were shown in two pivotal clinical trials. It was the aim of this study to evaluate the effect of 2% rebamipide ophthalmic suspension in patients with dry eye and analyze relevant factors for favorable effects of rebamipide in clinical practice. This was a retrospective cohort study of 48 eyes from 24 patients with dry eye treated with 2% rebamipide ophthalmic suspension. Dry eye-related symptom score, tear film break-up time (TBUT), fluorescein ocular surface staining score (FOS) and the Schirmer test were used to collect the data from patients at baseline, and at 2, 4, 8, and 12 week visits. To determine the relevant factors, multiple regression analyses were then performed. Mean dry eye-related symptom score showed a significant improvement from the baseline (14.5 points) at 2, 4, 8 and 12 weeks (9.80, 7.04, 7.04 and 7.83 points, corrected P value treatment. For ocular symptoms, three parameters (foreign body sensation, dry eye sensation and ocular discomfort) showed significant improvements at all visits. The multiple regression analyses showed that the fluorescein conjunctiva staining score was significantly correlated with the changes of dry eye-related symptom score at 12 weeks (P value = 0.017) and dry eye-related symptom score was significantly correlated with independent variables for the changes of FOS at 12 weeks (P value = 0.0097). Two percent rebamipide ophthalmic suspension was an effective therapy for dry eye patients. Moreover the fluorescein conjunctiva staining score and dry eye-related symptom score might be good relevant factors for favorable effects of rebamipide.

  13. Mucoadhesive Cyclodextrin-Modified Thiolated Poly(aspartic acid as a Potential Ophthalmic Drug Delivery System

    Directory of Open Access Journals (Sweden)

    Mária Budai-Szűcs

    2018-02-01

    Full Text Available Thiolated poly(aspartic acid is known as a good mucoadhesive polymer in aqueous ophthalmic formulations. In this paper, cyclodextrin-modified thiolated poly(aspartic acid was synthesized for the incorporation of prednisolone, a lipophilic ophthalmic drug, in an aqueous in situ gellable mucoadhesive solution. This polymer combines the advantages of cyclodextrins and thiolated polymers. The formation of the cyclodextrin-drug complex in the gels was analyzed by X-ray powder diffraction. The ocular applicability of the polymer was characterized by means of physicochemical, rheological and drug diffusion tests. It was established that the chemical bonding of the cyclodextrin molecule did not affect the complexation of prednisolone, while the polymer solution preserved its in situ gellable and good mucoadhesive characteristics. The chemical immobilization of cyclodextrin modified the diffusion profile of prednisolone and prolonged drug release was observed. The combination of free and immobilized cyclodextrins provided the best release profile because the free complex can diffuse rapidly, while the bonded complex ensures a prolonged action.

  14. Human eye analytical and mesh-geometry models for ophthalmic dosimetry using MCNP6

    International Nuclear Information System (INIS)

    Angelocci, Lucas V.; Fonseca, Gabriel P.; Yoriyaz, Helio

    2015-01-01

    Eye tumors can be treated with brachytherapy using Co-60 plaques, I-125 seeds, among others materials. The human eye has regions particularly vulnerable to ionizing radiation (e.g. crystalline) and dosimetry for this region must be taken carefully. A mathematical model was proposed in the past [1] for the eye anatomy to be used in Monte Carlo simulations to account for dose distribution in ophthalmic brachytherapy. The model includes the description for internal structures of the eye that were not treated in previous works. The aim of this present work was to develop a new eye model based on the Mesh geometries of the MCNP6 code. The methodology utilized the ABAQUS/CAE (Simulia 3DS) software to build the Mesh geometry. For this work, an ophthalmic applicator containing up to 24 model Amersham 6711 I-125 seeds (Oncoseed) was used, positioned in contact with a generic tumor defined analytically inside the eye. The absorbed dose in eye structures like cornea, sclera, choroid, retina, vitreous body, lens, optical nerve and optical nerve wall were calculated using both models: analytical and MESH. (author)

  15. Human eye analytical and mesh-geometry models for ophthalmic dosimetry using MCNP6

    Energy Technology Data Exchange (ETDEWEB)

    Angelocci, Lucas V.; Fonseca, Gabriel P.; Yoriyaz, Helio, E-mail: hyoriyaz@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Eye tumors can be treated with brachytherapy using Co-60 plaques, I-125 seeds, among others materials. The human eye has regions particularly vulnerable to ionizing radiation (e.g. crystalline) and dosimetry for this region must be taken carefully. A mathematical model was proposed in the past [1] for the eye anatomy to be used in Monte Carlo simulations to account for dose distribution in ophthalmic brachytherapy. The model includes the description for internal structures of the eye that were not treated in previous works. The aim of this present work was to develop a new eye model based on the Mesh geometries of the MCNP6 code. The methodology utilized the ABAQUS/CAE (Simulia 3DS) software to build the Mesh geometry. For this work, an ophthalmic applicator containing up to 24 model Amersham 6711 I-125 seeds (Oncoseed) was used, positioned in contact with a generic tumor defined analytically inside the eye. The absorbed dose in eye structures like cornea, sclera, choroid, retina, vitreous body, lens, optical nerve and optical nerve wall were calculated using both models: analytical and MESH. (author)

  16. Ophthalmic public health; the way ahead.

    Science.gov (United States)

    Heidary, F; Rahimi, A; Gharebaghi, R

    2012-01-01

    Visual sciences have been progressing quickly in recent decades through globalization phenomenon. An enormous change has taken place in ocular health issues, however, there are various problems facing ophthalmic public health worldwide. In the previous years, the World Health Organization and the International Agency for the Prevention of Blindness in partnership launched the global initiative to eradicate avoidable blindness by the year 2020, VISION 2020 the Right to Sight. It has concentrated on the prevention of blindness disability and recognized a health issue-sight as a human right. In view of challenges ahead of visual sciences, close collaboration between international agencies at the global level to implement new strategies and monitor the progress will be mandatory. In these circumstances non-governmental organizations should not be neglected. World Sight Day 2012 would be a great opportunity to be a focus on importance of visual impairment as an important public health issue and discovering new challenges ahead.

  17. Congenital glaucoma as an ophthalmic manifestation of Frank-Ter Haar syndrome.

    Science.gov (United States)

    Aktas, Zeynep; Karaca, Emine Esra; Dogan, Nurcan; Çakmak, Tugba; Unlu, Metin; Tok, Levent; Hasanreisoglu, Murat

    2014-04-01

    We report on a patient with Frank-Ter Haar syndrome that is associated with high intraocular pressures. A 21-day-old male patient was referred to our clinic for surgical treatment of congenital glaucoma. On ophthalmic examination, he had buphthalmos, mild corneal edema and high IOP readings in both eyes. The patient underwent uneventful trabeculotomy surgery, bilaterally. Marked bilateral anterior iris insertion was noted during the surgery. Childhood glaucoma may be associated with Frank-Ter Haar syndrome.

  18. To study the existing system of surgical safety for cataract surgery at tertiary care ophthalmic centre to implement WHO surgical safety checklist

    OpenAIRE

    Ruchi Garg; Neeraj Garg; Shakti Kumar Gupta; J. S. Titiyal; R. Mahesh

    2016-01-01

    Background: Dr. Rajendra Prasad Centre for Ophthalmic Sciences, named after the first President of India, was established on the 10th of March, 1967 as a National centre for ophthalmic science, to provide state of the art patient care, expand human resources for medical education and undertake research to find solutions to eye health problems of national importance. Average numbers of cataract surgeries performed per month are 700 to 1000. Methods: Anticipating implementation in 50% cases...

  19. Safety and efficacy of topical azithromycin ophthalmic solution 1.0% in the treatment of contact lens-related dry eye.

    Science.gov (United States)

    Nichols, Jason J; Bickle, Katherine M; Zink, Richard C; Schiewe, Michael D; Haque, Reza M; Nichols, Kelly K

    2012-03-01

    The purpose of this pilot study was to evaluate the safety and efficacy of azithromycin ophthalmic solution 1% in patients with contact lens-related dry eye (CLDE). This was a 4-week, single-center, open-label clinical trial in patients diagnosed with CLDE using the Contact Lens Dry Eye Questionnaire (CLDEQ). Fifty patients were enrolled in this study. The patients were randomized to 1 of 2 treatment groups: azithromycin ophthalmic solution administered bid on days 1 and 2 and on days 3 to 29±1 or Visine for Contacts rewetting drops administered qid on days 1 to 29±1. The patient diaries were used daily to collect data on comfortable and total contact lens wear time and ocular dryness throughout the treatment period. Tear osmolarity, fluorescein corneal staining, and visual acuity were also assessed during clinic visits. Fifty patients were enrolled, and 44 completed the study. One patient discontinued in the azithromycin group, and five patients discontinued in the rewetting drops group because of adverse events. A statistically significant increase in mean comfortable contact lens wear time from baseline was observed for the subjects treated with azithromycin ophthalmic solution as compared with the subjects treated with rewetting drops at week 4 (P=0.004; primary endpoint), in addition to weeks 2 and 3. The improvement in the mean comfortable wear time for the patients in the azithromycin treatment group exceeded 2 hrs throughout the treatment period (weeks 1-4). No significant differences were observed between the groups for total wear time, low contrast visual acuity, or tear osmolarity. Subject-rated ocular dryness (PM time assessments) was significantly improved from baseline in the subjects treated with azithromycin ophthalmic solution as compared with those treated with rewetting drops at weeks 2 and 3 endpoints (P=0.015 for each week). Additionally, a statistical difference was observed in favor of the azithromycin treatment group at week 2 for the

  20. Three percent diquafosol ophthalmic solution as an additional therapy to existing artificial tears with steroids for dry-eye patients with Sjögren's syndrome.

    Science.gov (United States)

    Yokoi, N; Sonomura, Y; Kato, H; Komuro, A; Kinoshita, S

    2015-09-01

    To investigate the long-term results of 3% diquafosol ophthalmic solution as an alternative therapy to existing ophthalmic solutions, including topical immunosuppression, for the treatment of dry eye in patients with Sjögren's syndrome. This study involved 14 female dry-eye patients (mean age: 62.4 years) with Sjögren's syndrome who insufficiently responded to their current therapy. In all patients, 3% diquafosol ophthalmic solution was administered six times daily for 12 months in substitution for artificial tears and sodium hyaluronate ophthalmic solution. Their use of corticosteroid eye drops remained unchanged from that prior to the treatment with diquafosol sodium. The subjective symptoms assessed, and ocular signs including tear meniscus radius and the tear film breakup time, and ocular-surface epithelial damage score were examined at 1, 2, 3, 4, 5, 6, 9, and 12 months after initiating treatment. Among the subjective symptoms, significant improvement was obtained in dryness at 2 months post treatment, in eye fatigue at 1, 2, 3, 4, and 12 months post treatment, and in pain at 1, 2, 6, and 12 months post treatment. Difficulty in opening the eye, foreign body sensation, and redness were also significantly ameliorated at various time-points. The tear meniscus radius and the tear film breakup time were significantly improved throughout the observation period, and the corneal epithelial staining scores were significantly decreased at 3 months post treatment. In dry-eye patients with Sjögren's syndrome, treatment with 3% diquafosol ophthalmic solution improved both symptoms and signs, and that effectiveness was maintained for 12 months.

  1. Extractables characterization for five materials of construction representative of packaging systems used for parenteral and ophthalmic drug products.

    Science.gov (United States)

    Jenke, Dennis; Castner, James; Egert, Thomas; Feinberg, Tom; Hendricker, Alan; Houston, Christopher; Hunt, Desmond G; Lynch, Michael; Shaw, Arthur; Nicholas, Kumudini; Norwood, Daniel L; Paskiet, Diane; Ruberto, Michael; Smith, Edward J; Holcomb, Frank

    2013-01-01

    Polymeric and elastomeric materials are commonly encountered in medical devices and packaging systems used to manufacture, store, deliver, and/or administer drug products. Characterizing extractables from such materials is a necessary step in establishing their suitability for use in these applications. In this study, five individual materials representative of polymers and elastomers commonly used in packaging systems and devices were extracted under conditions and with solvents that are relevant to parenteral and ophthalmic drug products (PODPs). Extraction methods included elevated temperature sealed vessel extraction, sonication, refluxing, and Soxhlet extraction. Extraction solvents included a low-pH (pH = 2.5) salt mixture, a high-pH (pH = 9.5) phosphate buffer, a 1/1 isopropanol/water mixture, isopropanol, and hexane. The resulting extracts were chemically characterized via spectroscopic and chromatographic means to establish the metal/trace element and organic extractables profiles. Additionally, the test articles themselves were tested for volatile organic substances. The results of this testing established the extractables profiles of the test articles, which are reported herein. Trends in the extractables, and their estimated concentrations, as a function of the extraction and testing methodologies are considered in the context of the use of the test article in medical applications and with respect to establishing best demonstrated practices for extractables profiling of materials used in PODP-related packaging systems and devices. Plastic and rubber materials are commonly encountered in medical devices and packaging/delivery systems for drug products. Characterizing the extractables from these materials is an important part of determining that they are suitable for use. In this study, five materials representative of plastics and rubbers used in packaging and medical devices were extracted by several means, and the extracts were analytically

  2. Comparative studies of various hyaluronic acids produced by microbial fermentation for potential topical ophthalmic applications

    DEFF Research Database (Denmark)

    Guillaumie, Fanny; Furrer, Pascal; Felt-Baeyens, Olivia

    2010-01-01

    This work presents a comparative study of various hyaluronic acids (HA) produced by fermentation of either Bacillus subtilis or Streptococcus towards the selection of an optimal molecular weight (MW) HA for the preparation of topical ophthalmic formulations. The influence of HA MW on water binding...

  3. Vascular resistance of central retinal and ophthalmic arteries in postmenopausal women after use of tibolone.

    Science.gov (United States)

    de Souza, Marco Aurélio Martins; de Souza, Bruno Martins; Geber, Selmo

    2012-03-01

    The aim of this study was to evaluate the effect of tibolone on vascular resistance of the central retinal and ophthalmic artery in postmenopausal women and to compare this effect with that of placebo using transorbital ultrasound with Doppler velocimetry. We performed a prospective randomized, double-blinded, placebo-controlled study. A total of 100 healthy postmenopausal women (follicle-stimulating hormone, >40 IU/L) younger than 65 years were studied. The participants were randomly allocated to two groups: placebo (n = 50) and tibolone (2.5 mg; n = 50). Transorbital Doppler velocimetric ultrasound was performed before treatment and 80 days after. The mean age was similar in both groups. Participants who received tibolone did not show any difference in pulsatility index, resistance index, and systole/diastole ratio of the central retinal and ophthalmic arteries after treatment. The same was observed in participants who received placebo. Our study demonstrates that tibolone administration to healthy postmenopausal women does not affect the resistance of small-caliber cerebral arteries.

  4. Safety in the use of compressed air versus oxygen for the ophthalmic patient.

    Science.gov (United States)

    Rodgers, Laura A; Kulwicki, Anahid

    2002-02-01

    Oxygen, routinely administered during surgery to avoid hypoxia, poses risks including increased likelihood of surgical room fires and predisposition to retinal phototoxicity in patients. Compressed air to supplement ventilation may be safer than oxygen. The purpose of this study was to determine whether hypoxia occurs more frequently when compressed air replaces supplemental oxygen during ophthalmic surgery. A convenience sample of 111 patients was randomly assigned to receive supplemental oxygen (group 1) or compressed air (group 2). Patients with serious cardiac or pulmonary disease were excluded. Blood oxygen levels were monitored during surgery by pulse oximetry. Oxygen was administered to all group 2 patients whose oxygen saturation fell to less than 90% or by more than 5% below baseline. No differences were observed between groups in age, ASA classification, type of surgery, or anesthetic drugs or doses. Minor, but statistically higher oxygen values were observed in group 1. The frequency with which oxygen saturation decreased below 90% or below 5% of baseline was similar in both groups. Supplemental oxygen is not required routinely in selected patients undergoing ophthalmic surgery. By using compressed air, the risk of operating room fires and retinal phototoxicity may be reduced.

  5. Polyethylene Naphthalate Scintillator: A Novel Detector for the Dosimetry of Radioactive Ophthalmic Applicators.

    Science.gov (United States)

    Flühs, Dirk; Flühs, Andrea; Ebenau, Melanie; Eichmann, Marion

    2015-09-01

    Dosimetric measurements in small radiation fields with large gradients, such as eye plaque dosimetry with β or low-energy photon emitters, require dosimetrically almost water-equivalent detectors with volumes of <1 mm(3) and linear responses over several orders of magnitude. Polyvinyltoluene-based scintillators fulfil these conditions. Hence, they are a standard for such applications. However, they show disadvantages with regard to certain material properties and their dosimetric behaviour towards low-energy photons. Polyethylene naphthalate, recently recognized as a scintillator, offers chemical, physical and basic dosimetric properties superior to polyvinyltoluene. Its general applicability as a clinical dosimeter, however, has not been shown yet. To prove this applicability, extensive measurements at several clinical photon and electron radiation sources, ranging from ophthalmic plaques to a linear accelerator, were performed. For all radiation qualities under investigation, covering a wide range of dose rates, a linearity of the detector response to the dose was shown. Polyethylene naphthalate proved to be a suitable detector material for the dosimetry of ophthalmic plaques, including low-energy photon emitters and other small radiation fields. Due to superior properties, it has the potential to replace polyvinyltoluene as the standard scintillator for such applications.

  6. Bimatoprost 0.03% preservative-free ophthalmic solution versus bimatoprost 0.03% ophthalmic solution (Lumigan) for glaucoma or ocular hypertension: a 12-week, randomised, double-masked trial

    Science.gov (United States)

    Day, Douglas G; Walters, Thomas R; Schwartz, Gail F; Mundorf, Thomas K; Liu, Charlie; Schiffman, Rhett M; Bejanian, Marina

    2013-01-01

    Background/Aim To evaluate efficacy and safety of bimatoprost 0.03% preservative-free (PF) ophthalmic solution versus bimatoprost 0.03% (Lumigan) ophthalmic solution for glaucoma or ocular hypertension. Methods In this double-masked, parallel-group study, patients were randomised to bimatoprost PF or bimatoprost for 12 weeks. The primary analysis for non-inferiority was change from baseline in worse eye intraocular pressure (IOP) in the per-protocol population at week 12. For equivalence, it was average eye IOP in the intent-to-treat population at each time point at weeks 2, 6 and 12. Results 597 patients were randomised (bimatoprost PF, n=302 and bimatoprost, n=295). The 95% CI upper limit for worse eye IOP change from baseline was <1.5 mm Hg at each week 12 time point, meeting prespecified non-inferiority criteria. The 95% CI upper limit for the treatment difference for average IOP was 0.69 mm Hg and the lower limit was −0.50 mm Hg at all follow-up time points (hours 0, 2 and 8 at weeks 2, 6 and 12), meeting equivalence criteria. Both treatments showed decreases in mean average eye IOP at all follow-up time points (p<0.001), were safe and well tolerated. Conclusions Bimatoprost PF is non-inferior and equivalent to bimatoprost in its ability to reduce IOP-lowering with a safety profile similar to bimatoprost. PMID:23743437

  7. A Case of Hydranencephaly in Which Ophthalmic Examinations Were Performed

    Directory of Open Access Journals (Sweden)

    Shohei Eda

    2016-09-01

    Full Text Available Purpose: We performed ophthalmic examinations, including optical coherence tomography (OCT, on a case diagnosed with hydranencephaly. Case Report: This case involved a female infant born at the gestational age of 35 weeks and 4 days, with the birth weight of 2,152 g, who was one of monochorionic diamniotic twins, and the identical twin died in utero at the gestational age of 24 weeks. After that, examination by fetal echo indicated that she had microcephaly and ventriculomegaly. Postnatal magnetic resonance imaging (MRI of her head indicated microcephaly and significant enlargement of the lateral ventricle on both sides, with no obvious signs of elevated intracranial pressure. The brain parenchyma of both sides of the frontal lobe, parietal lobe, and occipital lobe had marked thinning, yet that of the temporal lobe, basal ganglia, thalamus, brain stem, and cerebellum had been maintained. Moreover, no obvious hematoma or neoplastic lesions were observed. Ophthalmic examinations indicated that both of her eyes had slight light reflex, attributed to optic nerve atrophy. Examination by use of a hand-held OCT system indicated a layered structure of the retina and thinning of the ganglion cell layer. Flicker electroretinogram (ERG examination by use of a hand-held ERG system indicated an almost normal wave. However, no clear visual reaction was observed when she was 10 months old. Conclusion: Our findings in this case of hydranencephaly revealed that even though the outer layer functions of the patient’s retina were maintained, extensive damage to her cerebral cortex resulted in poor visual function.

  8. Ophthalmic evaluation of long-term survivors of childhood acute lymphoblastic leukemia

    International Nuclear Information System (INIS)

    Weaver, R.G. Jr.; Chauvenet, A.R.; Smith, T.J.; Schwartz, A.C.

    1986-01-01

    Thirty-four long-term survivors of childhood acute lymphoblastic leukemia (ALL) underwent comprehensive ophthalmic examinations to detect retinopathy or other ocular sequelae. Sixteen of the 34 patients received whole brain radiation (greater than or equal to 2400 rad). All 18 patients in the non-radiated group had normal eye examinations, while 4 of 16 in the radiated group had ocular abnormalities. None of the ocular abnormalities could be definitely attributed to radiation and all patients had normal visual acuity. No radiation retinopathy was found in either group

  9. Ophthalmic comlications of functional endoscopic sinus surgery

    Directory of Open Access Journals (Sweden)

    Sergey A. Karpishchenko

    2017-03-01

    Full Text Available Functional endoscopic sinus surgery (FESS is an effective and safe surgical technique, which revolutionized the surgical management of nasal cavity and paranasal sinus diseases. The intimate connection between paranasal sinuses and the orbit places the orbital content at a risk of injury during sinus surgery, especially that of ethmoid sinuses. The orbit, the optic nerve, extraocular muscles and the lacrimal drainage system could be damaged during FESS. The risk of injury correlates to anatomical variations, degree and severity of disease, previous procedure results, and surgical experience. Ophthalmic complications can vary in severity from minor ones, such as localized hematomas, to extremely dangerous, such as optic nerve injury, that could lead to complete blindness. In order to minimize the risk of such complications, it is necessary to consider probable anatomic variations of paranasal sinuses and orbit, which are to be detected by CT scan before surgery.

  10. Retinal protective effects of topically administered agmatine on ischemic ocular injury caused by transient occlusion of the ophthalmic artery

    Science.gov (United States)

    Hong, S.; Hara, H.; Shimazawa, M.; Hyakkoku, K.; Kim, C.Y.; Seong, G.J.

    2012-01-01

    Agmatine, an endogenous polyamine and putative neuromodulator, is known to have neuroprotective effects on various neurons in the central nervous system. We determined whether or not topically administered agmatine could reduce ischemic retinal injury. Transient ocular ischemia was achieved by intraluminal occlusion of the middle cerebral artery of ddY mice (30-35 g) for 2 h, which is known to also induce occlusion of the ophthalmic artery. In the agmatine group (N = 6), a 1.0 mM agmatine-containing ophthalmic solution was administered four times daily for 2 weeks before occlusion. In the control group (N = 6), a 0.1% hyaluronic acid ophthalmic solution was instilled at the same times. At 22 h after reperfusion, the eyeballs were enucleated and the retinal sections were stained by terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL). Transient ocular ischemia induced apoptosis of retinal cells in the entire retinal layer, and topically administered agmatine can significantly reduce this ischemic retinal injury. The proportion of apoptotic cells was definitely decreased (P agmatine application effectively decreases retinal damage in an in vivo ocular ischemic injury model. This implies that agmatine is a good candidate as a direct neuroprotective agent for eyes with ocular ischemic diseases. PMID:22331138

  11. Medical device development: managing conflicts of interest encountered by physicians.

    Science.gov (United States)

    Baim, Donald S; Donovan, Aine; Smith, John J; Briefs, Nancy; Geoffrion, Richard; Feigal, David; Kaplan, Aaron V

    2007-04-01

    New technologies introduced over the past three decades have transformed medical diagnosis and treatment, and significantly improved patient outcomes. These changes have been mediated by the introduction of new medical devices, particularly for the treatment of cardiovascular, orthopedic, and ophthalmic disorders. These devices, in turn, have created large markets and spawned a burgeoning medical device industry, including six Fortune 500 companies whose combined market capitalization now exceeds 400 billion dollars. This success story, which has unquestionably benefited patients and society alike, has been dependent upon an intense collaboration among industry, clinicians, and regulatory authorities. However, when physicians actively involved in patient care participate in such collaborations, they are increasingly vulnerable to creating potential conflicts between these two (clinical and device development) roles. Such conflicts, which may ultimately erode public trust, have important consequences not only for the individual physicians, but also for their parent institutions, their patients, sponsoring companies, and the entire clinical research enterprise that makes the development and introduction of new devices possible. The third Dartmouth Device Development Symposium held in October 2005 brought together thought leaders within the medical device community, including academicians, clinical investigators, regulators from the Food and Drug Administration and Centers for Medicare and Medicaid Services (CMS), large and small device manufacturers and the financial (venture capital and investment banks) community. The Symposium examined the conflicts of interest encountered during the early development and commercialization of a medical device. The goal of these discussions was to (1) identify and characterize the conflicts that arise and (2) provide strategies to address these conflicts. This manuscript was prepared by a writing committee to provide a summary

  12. Neuro-ophthalmic manifestation of neuromyelitis optica spectrum disorders

    Directory of Open Access Journals (Sweden)

    Xiao-jun ZHANG

    2014-10-01

    Full Text Available Neuromyelitis optica spectrum disorders (NMOSDs include classic neuromyelitis optica (NMO, opticospinal multiple sclerosis (OSMS, limited form of NMO and isolated optic neuritis or myelitis accompanied by either systemic autoimmune diseases or typical MRI findings of NMO. The common neuro-ophthalmic features of NMOSDs include simultaneous or consecutive bilateral optic neuritis, more commonly seen optic disk edema and surrounding exudate, poor visual recovery, steroid responsiveness and dependency. Combined with serum aquaporin 4 (AQP4 antibody and brain MRI examination, these clinical features can be helpful to the early differential diagnosis between NMOSDs and MS. Some types of eye movement abnormalities have been reported in patients with NMOSDs, but further investigation needs to be done before the specificity of these features are confirmed. doi: 10.3969/j.issn.1672-6731.2014.10.003

  13. Staff dose of hospitalization in the treatment of patients in ophthalmic brachytherapy with 125 I

    International Nuclear Information System (INIS)

    Terron Leon, J. A.; Gomez Palacios, M.; Moreno Reyes, J. C.; Perales Molina, A.

    2013-01-01

    The objective of this work, therefore, has been the evaluation of the dose levels which nursing staff can receive in care for ophthalmic brachytherapy patients treated with 125 I from measurements made on the same, evaluating, in an experimental way, job security following the PR rules laid down for these treatments. (Author)

  14. Formulation and stability of an extemporaneous 0.02% chlorhexidine digluconate ophthalmic solution.

    Science.gov (United States)

    Lin, Shu-Chiao; Huang, Chih-Fen; Shen, Li-Jiuan; Wang, Hsueh-Ju; Lin, Chia-Yu; Wu, Fe-Lin Lin

    2015-12-01

    Acanthamoeba keratitis is difficult to treat because Acanthamoeba cysts are resistant to the majority of antimicrobial agents. Despite the efficacy of 0.02% chlorhexidine in treating Acanthamoeba keratitis, a lack of data in the literature regarding the formulation's stability limits its clinical use. The objective of this study was to develop an optimal extemporaneous 0.02% chlorhexidine digluconate ophthalmic formulation for patients in need. With available active pharmaceutical ingredients, 0.02% chlorhexidine digluconate sample solutions were prepared by diluting with BSS Plus Solution or acetate buffer. Influences of the buffer, type of container, and temperature under daily-open condition were assessed based on the changes of pH values and chlorhexidine concentrations of the test samples weekly. To determine the beyond-use date, the optimal samples were stored at 2-8°C or room temperature, and analyzed at time 0 and at Week 1, Week 2, Week 3, Week 4, Week 5, Week 8, Week 12, and Week 24. Despite chlorhexidine exhibiting better stability in acetate buffer than in BSS solution, its shelf-life was stability at 2-25°C for 6 months after being sealed and for 1 month after opening. This finding will enable us to prepare 0.02% chlorhexidine digluconate ophthalmic solutions based on a doctor's prescription. Copyright © 2014. Published by Elsevier B.V.

  15. Hydroxychloroquine screening practice patterns within a large multispecialty ophthalmic practice.

    Science.gov (United States)

    Au, Adrian; Parikh, Vishal; Modi, Yasha S; Ehlers, Justis P; Schachat, Andrew P; Singh, Rishi P

    2015-09-01

    To determine provider compliance with hydroxychloroquine screening following the revised recommendations published in 2011 by the American Academy of Ophthalmology. Evaluation of adherence to a screening protocol. Subjects were identified with hydroxychloroquine as a medication by electronic query at a large multispecialty ophthalmic practice. Patients were excluded if patients: (1) were screened by an outside physician; (2) lacked recorded height, weight, start date, or dosing; or (3) took hydroxychloroquine for malaria prophylaxis. Screening tests were stratified by ophthalmic subspecialty. Guidelines define proper screening as 1 subjective test-Humphrey visual field (HVF), and 1 objective test-spectral-domain optical coherence tomography (SD OCT), fundus autofluorescence (FAF), or multifocal electroretinography (mfERG). Adherence to guidelines was determined by categorizing practices as: (1) "appropriate"-consistent with guidelines; (2) "underscreened"-insufficient testing; or (3) "inappropriate"-no testing. The study comprised 756 patients with a mean age of 56 years undergoing 1294 screening visits. Twenty-one patients received initial screenings outside the institution. Most common screening tests employed included SD OCT (56.6%), 10-2 HVF (55.0%), and Amsler grid (40.0%). Of the 735 initial screenings, 341 (46.4%) were appropriately screened, 204 (27.8%) underscreened, and 190 (25.9%) inappropriately screened. Of those who presented solely for screening (560), 307 (54.8%) were appropriately screened, 144 (25.7%) underscreened, and 109 (19.5%) inappropriately screened. Of patients presenting for hydroxychloroquine screening, 54.8% of patients received appropriate evaluation, indicating lack of adherence to guidelines. Overall, SD OCT and 10-2 HVF were the preferred screening modalities, with FAF and mfERG less frequently ordered. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. [Pediatric case series in an ophthalmic camp in Turkana (Kenya)].

    Science.gov (United States)

    Noval, S; Cabrejas, L; Jarrín, E; Ruiz-Guerrero, M; Ciancas, E

    2013-12-01

    Turkana is the largest district in Kenya, situated in the Northwest of the country. It features a semi-nomadic population of 850,000. Around 60% of population lives below the poverty threshold. The ratio of doctors is 1:75,000 inhabitants. Five ophthalmologists took part in the last deployment in November. Local staff had previously selected the patients from the rural areas, as well as in Lodwar, the capital of the district. Of the 371 patients who attended the clinic, 128 required surgery. To describe the pediatric population attended to in the last «Turkana Eye Project» Camp. Description of the ophthalmic pathologies of the children seen in the clinic in this surgical camp, and the diagnostic and therapeutic options according to the limitations of the environment. Of the 371 patients, 54 were younger than 15 years old (14.5%). Four children had surgery (3.25% of the 128 patients). In 2 more cases surgery was the indicated but not performed. Therefore, of the total of 54 cases, 6 could be considered as surgical (11.1%), and 17 suffered ophthalmic problems other than refraction defects, or mild ocular surface pathologies: traumatic cataracts, neuropathies, impetigo, exophthalmos, retinal dystrophies, dermoid cysts, or nyctalopia. The etiology was traumatic in four of the 17 children (23.5%). Surgical camps are increasing in the developing countries. They are usually focused on particular pathologies, such as cataracts or trachoma. Our case series shows the importance of pediatric teams and the need to be prepared to face complex pediatric pathologies. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  17. Optimization of 125I ophthalmic plaque brachytherapy

    International Nuclear Information System (INIS)

    Astrahan, M.A.; Luxton, G.; Jozsef, G.; Liggett, P.E.; Petrovich, Z.

    1990-01-01

    Episcleral plaques containing 125 I sources are often used in the treatment of ocular melanoma. Within four years post-treatment, however, the majority of patients experience some visual loss due to radiation retinopathy. The high incidence of late complications suggests that careful treatment optimization may lead to improved outcome. The goal of optimization would be to reduce the magnitude of vision-limiting complications without compromising tumor control. We have developed a three-dimensional computer model for ophthalmic plaque therapy which permits us to explore the potential of various optimization strategies. One simple strategy which shows promise is to maximize the ratio of dose to the tumor apex (T) compared to dose to the macula (M). By modifying the parameters of source location, activity distribution, source orientation, and shielding we find that the calculated T:M ratio can be varied by a factor of 2 for a common plaque design and posterior tumor location. Margins and dose to the tumor volume remain essentially unchanged

  18. A History of the Sonocare CST-100: The First FDA-approved HIFU Device

    Science.gov (United States)

    Muratore, Robert

    2006-05-01

    The Sonocare CST-100 Therapeutic Ultrasound System, designed for the treatment of glaucoma, was developed in the 1980s and became the first high intensity focused ultrasound (HIFU) device to receive Food and Drug Administration approval. The system arose from studies done by F.L. Lizzi, Eng.Sc.D., of Riverside Research Institute and D.J. Coleman, M.D., of Cornell Medical Center/New York Hospital on the safety of ultrasound diagnosis of the eye. As safety limits were probed, therapeutic regimes were discovered. Optimization of operational parameters, clinical experience, and engineering design came together through a spin-off company, Sonocare, Inc., formed to produce and market the ophthalmic device. Various precedents were set during the approval process, including the acceptance by the FDA of radiation momentum imparted to an absorber as a measure of acoustic power. Many devices were sold, but the laser industry, grandfathered into the therapeutic field, eventually out-marketed Sonocare. The CST-100 remains as a model of elegant industrial design, and existing units are used daily in HIFU laboratory experiments.

  19. Safety of Lifitegrast Ophthalmic Solution 5.0% in Patients With Dry Eye Disease: A 1-Year, Multicenter, Randomized, Placebo-Controlled Study.

    Science.gov (United States)

    Donnenfeld, Eric D; Karpecki, Paul M; Majmudar, Parag A; Nichols, Kelly K; Raychaudhuri, Aparna; Roy, Monica; Semba, Charles P

    2016-06-01

    To evaluate the 1-year safety of lifitegrast ophthalmic solution 5.0% in patients with dry eye disease compared with placebo. SONATA (Safety Of a 5.0% coNcentrATion of lifitegrAst ophthalmic solution) was a multicenter, randomized, prospective, double-masked, placebo-controlled phase 3 study (NCT01636206). Adults (≥18 years) with dry eye disease (Schirmer test score ≥1 and ≤10 mm; corneal staining score ≥2.0) were randomized 2:1 to lifitegrast ophthalmic solution 5.0% or placebo twice daily for 360 days. The primary objective was percentage and severity of treatment-emergent adverse events (TEAEs). Secondary objectives were ocular safety measures: corneal fluorescein staining, drop comfort, best-corrected visual acuity, slit-lamp biomicroscopy, and intraocular pressure over 7 visits. Exploratory objectives included concentration of lifitegrast in plasma. The safety population comprised 331 participants (220 lifitegrast; 111 placebo). There were no serious ocular TEAEs. Overall, 53.6% of participants receiving lifitegrast experienced ≥1 ocular TEAE versus 34.2% in the placebo group; most TEAEs were mild to moderate in severity. Rates of discontinuation because of TEAEs were 12.3% (lifitegrast) versus 9.0% (placebo). The most common (>5%) TEAEs occurring in either treatment group were instillation site irritation (burning), instillation site reaction, visual acuity reduced, dry eye, and dysgeusia (change in taste). Ocular safety parameters for lifitegrast were similar to placebo. The mean plasma lifitegrast concentration at 360 days (n = 43) was below the limit of detection. There was no indication of systemic toxicity or localized infectious complications secondary to chronic immunosuppression. Lifitegrast ophthalmic solution 5.0% seemed safe and well tolerated in this study, with no unexpected adverse events.

  20. The Efficacy of 1% Chloramphenicol Eye Ointment Versus 2.5% Povidone-Iodine Ophthalmic Solution in Reducing Bacterial Colony in Newborn Conjunctivae.

    Science.gov (United States)

    Bramantyo, Triwijayanti; Roeslani, Rosalina Dewi; Andriansjah, Andriansjah; Sitorus, Rita S

    2015-01-01

    This study aimed to evaluate bacterial pattern and reduction of bacterial colonies in neonatal conjunctivae after prophylaxis 1% chloramphenicol eye ointment and 2.5% povidone-iodine ophthalmic solution. A double-blind randomized controlled trial was conducted. Swabs were taken from the inferior fornix conjunctiva of the right eyes of 60 newborns 1 hour after birth. Either the 2.5% povidone-iodine ophthalmic solution or the 1% chloramphenicol eye ointment was randomly applied to the conjunctivae. Conjunctival swabs were taken 2 hours after prophylaxis treatment. Specimens were delivered to the Microbiology Laboratory to determine the number of bacterial colonies and to evaluate bacterial pattern. Sixty eye specimens were included in the study. Bacterial growth was shown in 44 eye specimens, whereas it was not found in the remaining 16 eye specimens. The bacteria found in neonatal conjunctivae was gram-positive coccus (61%), followed by gram-positive bacillus (36%) and gram-negative bacillus (2%). Both agents significantly reduced the bacterial colony-forming unit (P = 0.00); however, the effect was not significantly different as shown by statistics between both groups (P = 0.748), indicating that the 2.5% povidone-iodine ophthalmic solution had a similar effect to the 1% chloramphenicol eye ointment. No adverse effect such as toxic conjunctivitis or corneal haziness was found in both groups. The 2.5% povidone-iodine ophthalmic solution has been proven as effective as the 1% chloramphenicol eye ointment and induces no toxic reaction. Because it is less expensive than the other, it could be recommended as a good alternative for ophthalmia neonatorum prophylaxis. Further studies with a larger sample size should be conducted to confirm its cost-effectiveness.

  1. Risk of Hemorrhage during Needle-Based Ophthalmic Regional Anesthesia in Patients Taking Antithrombotics: A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Augusto Takaschima

    Full Text Available Patients undergoing ophthalmic surgery are usually elderly and, due to systemic disease, may be on long-term therapy, such as antithrombotic agents. Rates of hemorrhagic complications associated with invasive procedures may be increased by the use of anticoagulants and antiplatelet agents.To compare the incidence of hemorrhagic complications in patients undergoing needle-based ophthalmic regional anesthesia between patients on antithrombotic therapy and those not on such therapy.A systematic review was conducted by two independent reviewers based on searches of Cochrane, LILACS, PubMed, Scopus, Web of Science, and the "gray" literature (Google Scholar. The end search date was May 8, 2015, across all databases.Five studies met the eligibility criteria. In three studies, individual risk of bias was low, and in two of them, moderate. In all studies, no differences regarding mild to moderate incidence of hemorrhagic complications were found between patients using antithrombotics (aspirin, clopidogrel, and warfarin and those not using them. Rates of severe hemorrhagic complication were very low (0.04% in both groups, supporting the safety of needle blocks, even in patients using antithrombotics. High heterogeneity across studies prevented meta-analysis. Limitations to these results include low statistical power in three experimental studies and a large 95% confidence interval in the two retrospective cohorts.In this review, none of the selected studies showed significant bleeding related to needle-based ophthalmic regional anesthesia in association with the use of aspirin, clopidogrel, or vitamin K inhibitors. Since the available data is not powerful enough to provide a reliable evaluation of the true effect of antithrombotics in this setting, new studies to address these limitations are necessary.

  2. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    Science.gov (United States)

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and

  3. Ophthalmic nepafenac use in the Netherlands and Denmark

    DEFF Research Database (Denmark)

    Margulis, Andrea V.; Houben, Eline; Hallas, Jesper

    2017-01-01

    Purpose: To describe nepafenac use in the Netherlands and Denmark with reference to its approved indications. For context, we also describe the use of ketorolac and diclofenac. Methods: We identified users in the PHARMO Database Network (the Netherlands, 2008–2013) and the Danish national health...... registers (Denmark, 1994–2014). We described prevalence of cataract surgery and duration of use in patients with cataract surgery with and without diabetes. Results: In the Netherlands, 9530 nepafenac users (mean age, 71 years; 60% women) contributed 12 691 therapy episodes, of which 21% had a recently...... dispensed. Use patterns of nepafenac, ketorolac and diclofenac were roughly similar in the Netherlands, but not in Denmark. Conclusion: Less than half of therapy episodes were related to cataract surgery; around 90% of episodes with surgery were within the approved duration. Underrecording of ophthalmic...

  4. Study and development of an Iridium-192 seed for use in ophthalmic cancer

    International Nuclear Information System (INIS)

    Mattos, Fabio Rodrigues de

    2013-01-01

    Even ocular tumors are not among the cases with a higher incidence, they affect the population, especially children. The Institute of Energy and Nuclear Research (IPEN-CNEN/SP) in partnership with Escola Paulista de Medicina (UNIFESP), created a project to develop and implement a alternative treatment for ophthalmic cancer that use brachytherapy iridium-192 seeds. The project arose by reason of the Escola Paulista treat many cancer cases within the Unified Health System (SUS) and the research experience of sealed radioactive sources group at IPEN. The methodology was developed from the available infrastructure and the experience of researchers. The prototype seed presents with a core (192-iridium alloy of iridium-platinum) of 3.0 mm long sealed by a capsule of titanium of 0.8 mm outside diameter, 0.05 mm wall thickness and 4,5mm long. This work aims to study and develop a seed of iridium-192 from a platinum-iridium alloy. No study on the fabrication of these seeds was found in available literature. It was created a methodology that involved: characterization of the material used in the core, creation of device for neutron activation irradiation and and seed sealing tests. As a result, proved the feasibility of the method. As a suggestion for future work, studies regarding metrology and dosimetry of these sources and improvement of the methodology should be carried out, for future implementation in national scope. (author)

  5. Effect of diquafosol ophthalmic solution on the optical quality of the eyes in patients with aqueous-deficient dry eye.

    Science.gov (United States)

    Koh, Shizuka; Maeda, Naoyuki; Ikeda, Chikako; Oie, Yoshinori; Soma, Takeshi; Tsujikawa, Motokazu; Watanabe, Hitoshi; Nishida, Kohji

    2014-12-01

    To investigate the short- and long-term effects of diquafosol ophthalmic solution on the optical quality of the eyes in patients with aqueous-deficient dry eye. Sixteen eyes in 16 patients with mild or moderate aqueous-deficient dry eye were treated with 3% diquafosol ophthalmic solution. Ocular higher-order aberrations (HOAs) were measured with a wavefront sensor before and at 15 min after diquafosol instillation at the baseline visit and at 4 weeks after treatment initiation. Dry eye symptoms, tear break-up time (BUT), corneal/conjunctival fluorescein staining and Schirmer's test were also evaluated before and after treatment with diquafosol. Treatment with diquafosol ophthalmic solution significantly improved dry eye symptoms, corneal staining and BUT. Compared with mean total HOAs at baseline (0.180 ± 0.06 μm), those at 4 weeks after treatment significantly decreased (0.148 ± 0.039 μm; p = 0.035), whereas those 15 min after diquafosol instillation at the baseline visit did not change significantly (0.170 ± 0.049 μm; p = 0.279). Although no significant change in HOAs was observed as a short-term effect of a single-drop instillation of diquafosol, long-term use of diquafosol to treat aqueous-deficient dry eye reduced HOAs as well as improved corneal epithelial damage and tear film stability. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. Retinal protective effects of topically administered agmatine on ischemic ocular injury caused by transient occlusion of the ophthalmic artery

    Directory of Open Access Journals (Sweden)

    S. Hong

    2012-03-01

    Full Text Available Agmatine, an endogenous polyamine and putative neuromodulator, is known to have neuroprotective effects on various neurons in the central nervous system. We determined whether or not topically administered agmatine could reduce ischemic retinal injury. Transient ocular ischemia was achieved by intraluminal occlusion of the middle cerebral artery of ddY mice (30-35 g for 2 h, which is known to also induce occlusion of the ophthalmic artery. In the agmatine group (N = 6, a 1.0 mM agmatine-containing ophthalmic solution was administered four times daily for 2 weeks before occlusion. In the control group (N = 6, a 0.1% hyaluronic acid ophthalmic solution was instilled at the same times. At 22 h after reperfusion, the eyeballs were enucleated and the retinal sections were stained by terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL. Transient ocular ischemia induced apoptosis of retinal cells in the entire retinal layer, and topically administered agmatine can significantly reduce this ischemic retinal injury. The proportion of apoptotic cells was definitely decreased (P < 0.001; Kruskal-Wallis test. Overall, we determined that topical agmatine application effectively decreases retinal damage in an in vivo ocular ischemic injury model. This implies that agmatine is a good candidate as a direct neuroprotective agent for eyes with ocular ischemic diseases.

  7. Comparison of ophthalmic sponges and extraction buffers for quantifying cytokine profiles in tears using Luminex technology.

    Science.gov (United States)

    Inic-Kanada, Aleksandra; Nussbaumer, Andrea; Montanaro, Jacqueline; Belij, Sandra; Schlacher, Simone; Stein, Elisabeth; Bintner, Nora; Merio, Margarethe; Zlabinger, Gerhard J; Barisani-Asenbauer, Talin

    2012-01-01

    Evaluating cytokine profiles in tears could shed light on the pathogenesis of various ocular surface diseases. When collecting tears with the methods currently available, it is often not possible to avoid the tear reflex, which may give a different cytokine profile compared to basal tears. More importantly, tear collection with glass capillaries, the most widely used method for taking samples and the best method for avoiding tear reflex, is impractical for remote area field studies because it is tedious and time-consuming for health workers, who cannot collect tears from a large number of patients with this method in one day. Furthermore, this method is uncomfortable for anxious patients and children. Thus, tears are frequently collected using ophthalmic sponges. These sponges have the advantage that they are well tolerated by the patient, especially children, and enable standardization of the tear collection volume. The aim of this study was to compare various ophthalmic sponges and extraction buffers to optimize the tear collection method for field studies for subsequent quantification of cytokines in tears using the Luminex technology. Three ophthalmic sponges, Merocel, Pro-ophta, and Weck-Cel, were tested. Sponges were presoaked with 25 cytokines/chemokines of known concentrations and eluted with seven different extraction buffers (EX1-EX7). To assess possible interference in the assay from the sponges, two standard curves were prepared in parallel: 1) cytokines of known concentrations with the extraction buffers and 2) cytokines of known concentrations loaded onto the sponges with the extraction buffers. Subsequently, a clinical assessment of the chosen sponge-buffer combination was performed with tears collected from four healthy subjects using 1) aspiration and 2) sponges. To quantify cytokine/chemokine recovery and the concentration in the tears, a 25-plex Cytokine Panel and the Luminex xMap were used. This platform enables simultaneous measurement of

  8. Comparison of ophthalmic sponges and extraction buffers for quantifying cytokine profiles in tears using Luminex technology

    Science.gov (United States)

    Inic-Kanada, Aleksandra; Nussbaumer, Andrea; Montanaro, Jacqueline; Belij, Sandra; Schlacher, Simone; Stein, Elisabeth; Bintner, Nora; Merio, Margarethe; Zlabinger, Gerhard J.

    2012-01-01

    Purpose Evaluating cytokine profiles in tears could shed light on the pathogenesis of various ocular surface diseases. When collecting tears with the methods currently available, it is often not possible to avoid the tear reflex, which may give a different cytokine profile compared to basal tears. More importantly, tear collection with glass capillaries, the most widely used method for taking samples and the best method for avoiding tear reflex, is impractical for remote area field studies because it is tedious and time-consuming for health workers, who cannot collect tears from a large number of patients with this method in one day. Furthermore, this method is uncomfortable for anxious patients and children. Thus, tears are frequently collected using ophthalmic sponges. These sponges have the advantage that they are well tolerated by the patient, especially children, and enable standardization of the tear collection volume. The aim of this study was to compare various ophthalmic sponges and extraction buffers to optimize the tear collection method for field studies for subsequent quantification of cytokines in tears using the Luminex technology. Methods Three ophthalmic sponges, Merocel, Pro-ophta, and Weck-Cel, were tested. Sponges were presoaked with 25 cytokines/chemokines of known concentrations and eluted with seven different extraction buffers (EX1–EX7). To assess possible interference in the assay from the sponges, two standard curves were prepared in parallel: 1) cytokines of known concentrations with the extraction buffers and 2) cytokines of known concentrations loaded onto the sponges with the extraction buffers. Subsequently, a clinical assessment of the chosen sponge-buffer combination was performed with tears collected from four healthy subjects using 1) aspiration and 2) sponges. To quantify cytokine/chemokine recovery and the concentration in the tears, a 25-plex Cytokine Panel and the Luminex xMap were used. This platform enables simultaneous

  9. A randomised, parallel-group comparison study of diquafosol ophthalmic solution in patients with dry eye in China and Singapore.

    Science.gov (United States)

    Gong, Lan; Sun, Xinghuai; Ma, Zhizhong; Wang, Qinmei; Xu, Xun; Chen, Xiaoming; Shao, Yan; Yao, Ke; Tang, Luosheng; Gu, Yangshun; Yuan, Huiping; Chua, Wei Han; Chuan, Jacob Cheng Yen; Tong, Louis

    2015-07-01

    To compare the efficacy and safety of 3% diquafosol ophthalmic solution with those of 0.1% sodium hyaluronate ophthalmic solution in patients with dry eye in China and Singapore. A total of 497 patients with dry eye (Schirmer's test, 5 mm; fluorescein and RB score, 3 points) from China and Singapore were randomised to receive either diquafosol ophthalmic solution (diquafosol) or sodium hyaluronate ophthalmic solution (HA) at 1:1 ratio. The fluorescein staining scores and rose bengal (RB) subjective symptom scores and tear film breakup time were evaluated before treatment and 2 and 4 weeks after start of treatment. In the diquafosol group, changes in fluorescein and RB scores compared with baseline at week 4 or at the time of discontinuation were -2.1±1.5 and -2.5±2.0, respectively. Compared with the HA group, changes in fluorescein score were non-inferior and changes in RB score were superior (p=0.019). In addition, diquafosol and HA improved tear film breakup time by 1.046±1.797 and 0.832±1.775 s, respectively (no significant intergroup difference). Adverse event onset rates were 16.3% (40 of 246 subjects) and 10.0% (25 of 251 subjects) in the diquafosol group and HA group, respectively, with borderline significant intergroup differences (p=0.046), while adverse drug reaction incidence rates were 12.2% (30 of 246 subjects) and 6.0% (15 of 251 subjects), respectively (p=0.019). Only mild adverse drug reactions (>2%) in the form of eye discharge, itching or irritation were observed. Diquafosol improved fluorescein staining score in a manner similar to HA, and significantly improved RB score compared with HA. NCT01101984. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Ophthalmic artery chemosurgery: A nursing perspective

    Directory of Open Access Journals (Sweden)

    Mary Elizabeth Davis

    2017-01-01

    Full Text Available Retinoblastoma (RB is the most common primary cancer to affect the eyes in children with approximately 350 cases/year in the United States and 8000 worldwide. Today, sadly, 50% of children with RB worldwide die from their disease. In our experience, utilization of ophthalmic artery chemosurgery (OAC has transformed the treatment plan for patients; with over 1500 procedures performed, our survival rate exceeds 98%. It is now our standard first-line therapy for RB. OAC is a surgical outpatient procedure which delivers concentrated doses of chemotherapy directly to the tumor without the toxicities of systemic chemotherapy. Our team approach and nursing management of these patients are the focus of this article. Nursing navigation and collaboration after OAC is vital and requires a combined effort by the nurses along with physicians, interventional radiologists, and the patient's families to ensure appropriate follow-up is established. Proper patient education throughout the process is crucial as is open and available communication for parents of patients with the nursing staff. The success in our treatment of this disease can be much accredited to the multidisciplinary team approach, with nursing playing an integral part in the support and management of these patients.

  11. 76 FR 28045 - Determination That XIBROM (Bromfenac Ophthalmic Solution) 0.09% Was Not Withdrawn From Sale for...

    Science.gov (United States)

    2011-05-13

    ... marketing for reasons other than safety or effectiveness. ANDAs that refer to XIBROM (bromfenac ophthalmic... Safety or Effectiveness AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and... withdrawn from sale for reasons of safety or effectiveness. This determination will allow FDA to approve...

  12. Ocular pharmacokinetics comparison between 0.2% olopatadine and 0.77% olopatadine hydrochloride ophthalmic solutions administered to male New Zealand white rabbits.

    Science.gov (United States)

    Iyer, Ganesh R; Cason, Marita M; Womble, Scott W; Li, Guangming; Chastain, James E

    2015-05-01

    The primary objective of this study was to compare uptake and distribution of the commercially available formulation of 0.2% olopatadine and the newly developed 0.77% olopatadine hydrochloride ophthalmic solution formulation with improved solubility following a single (30 μL), bilateral topical ocular dose in male New Zealand white rabbits. Each animal received a single 30-μL topical ocular dose (0.2% olopatadine or 0.77% olopatadine hydrochloride ophthalmic solution) to the right (OD) eye followed by the left (OS) eye for a total dose of 60 μL. Olopatadine concentrations were measured in ocular tissues (cornea, bulbar, conjunctiva, choroid, iris-ciliary body, whole lens, retina), aqueous humor, and plasma at prespecified time points over 24 h using a qualified liquid chromatography coupled with mass spectrometry (LC-MS/MS) analytical method. Olopatadine was absorbed into the eye and reached maximal levels (Cmax) within 30 min (0.5 h) to 2 h (Tmax) in ocular tissues and plasma for both treatment groups, except for the lens in which the Tmax was 4 h in the 0.2% olopatadine group and 8 h in the 0.77% olopatadine hydrochloride group, respectively. Tissues associated with the site of dosing, that is, the conjunctiva and cornea, had the highest concentrations of olopatadine in both the 0.2% olopatadine (609 and 720 ng/g) and 0.77% olopatadine hydrochloride (3,000 and 2,230 ng/g) dose groups. The greatest differences between 0.2% olopatadine and 0.77% olopatadine hydrochloride were associated with the overall duration and level of ocular exposures. The newly developed 0.77% olopatadine hydrochloride ophthalmic solution formulation resulted in a higher and more prolonged olopatadine concentration in the target tissue, that is, conjunctiva compared to the commercial formulation of 0.2% olopatadine ophthalmic solution.

  13. Ophthalmic Vascular Events after Primary Unilateral Intra-arterial Chemotherapy for Retinoblastoma in Early and Recent Eras.

    Science.gov (United States)

    Dalvin, Lauren A; Ancona-Lezama, David; Lucio-Alvarez, J Antonio; Masoomian, Babak; Jabbour, Pascal; Shields, Carol L

    2018-06-16

    To assess risk factors for ophthalmic vascular events after intra-arterial chemotherapy (IAC) for retinoblastoma. Retrospective cohort study. Patients who received unilateral IAC as primary treatment for retinoblastoma from January 1, 2009, to November 30, 2017, at a single center. Records were reviewed for patient demographics, tumor features, IAC parameters, and treatment-related vascular events in the early IAC era (2009-2011) compared with the recent era (2012-2017) using the t test and Fisher exact test. Change in event rates over time was assessed using Poisson regression analysis, with Spearman's rho used to test correlation. Rate of IAC-induced ophthalmic vascular events. There were 243 chemotherapy infusions in 76 eyes of 76 patients, divided into early (22 eyes, 57 infusions) and recent (54 eyes, 186 infusions) eras. Intra-arterial chemotherapy consisted of melphalan (243 infusions), topotecan (124 infusions), and carboplatin (9 infusions). A comparison (early vs. recent era) revealed fewer mean number of infusions (2.6 vs. 3.4, P = 0.02) with similar mean patient age and presenting tumor features. Event rates decreased over time (P early era vs. recent era) in the recent era (59% vs. 9% per eye, 23% vs. 3% per infusion, P age (P = 0.75), tumor diameter (P = 0.32), tumor thickness (P = 0.59), or cumulative dosage of melphalan (P = 0.13) or topotecan (P = 0.59). There were no IAC-induced vascular events in 72 infusions of 21 consecutively treated eyes in 2016 to 2017. Ophthalmic vascular events after IAC have decreased from the early era (2009-2011) through the current era (2012-2017) at this center. Experience performing this highly specialized procedure could be an important factor predicting IAC-related vascular events. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Besifloxacin ophthalmic suspension 0.6% in patients with bacterial conjunctivitis: A multicenter, prospective, randomized, double-masked, vehicle-controlled, 5-day efficacy and safety study.

    Science.gov (United States)

    Karpecki, Paul; Depaolis, Michael; Hunter, Judy A; White, Eric M; Rigel, Lee; Brunner, Lynne S; Usner, Dale W; Paterno, Michael R; Comstock, Timothy L

    2009-03-01

    Besifloxacin ophthalmic suspension 0.6% is a new topical fluoroquinolone for the treatment of bacterial conjunctivitis. Besifloxacin has potent in vitro activity against a broad spectrum of ocular pathogens, including drug-resistant strains. The primary objective of this study was to compare the clinical and microbiologic efficacy of besifloxacin ophthalmic suspension 0.6% with that of vehicle (the formulation without besifloxacin) in the treatment of bacterial conjunctivitis. This was a multicenter, prospective, randomized, double-masked, vehicle-controlled, parallel-group study in patients with acute bacterial conjunctivitis. Patients received either topical besifloxacin ophthalmic suspension or vehicle administered 3 times daily for 5 days. At study entry and on days 4 and 8 (visits 2 and 3), a clinical assessment of ocular signs and symptoms was performed in both eyes, as well as pinhole visual acuity testing, biomicroscopy, and culture of the infected eye(s). An ophthalmoscopic examination was performed at study entry and on day 8. The primary efficacy outcome measures were clinical resolution and eradication of the baseline bacterial infection on day 8 in culture-confirmed patients. The safety evaluation included adverse events, changes in visual acuity, and biomicroscopy and ophthalmoscopy findings in all patients who received at least 1 dose of active treatment or vehicle. The safety population consisted of 269 patients (mean [SD] age, 34.2 [22.3] years; 60.2% female; 82.5% white) with acute bacterial conjunctivitis. The culture-confirmed intent-to-treat population consisted of 118 patients (60 besifloxacin ophthalmic suspension, 58 vehicle). Significantly more patients receiving besifloxacin ophthalmic suspension than vehicle had clinical resolution of the baseline infection at visit 3 (44/60 [73.3%] vs 25/58 [43.1%], respectively; P suspension compared with vehicle at visit 3 (53/60 [88.3%] vs35/58 [60.3%]; P suspension 0.6% given 3 times daily for 5 days

  15. Diquafosol Ophthalmic Solution Increases Pre- and Postlens Tear Film During Contact Lens Wear in Rabbit Eyes.

    Science.gov (United States)

    Nagahara, Yukiko; Koh, Shizuka; Oshita, Yoshihiro; Nagano, Takashi; Mano, Hidetoshi; Nishida, Kohji; Watanabe, Hitoshi

    2017-11-01

    To investigate the behavior of prelens tear film (PLTF) and postlens tear film (PoLTF) after the instillation of diquafosol using an experimental rabbit model of eyes with contact lens. Cross-sectional, anterior segment optical coherence tomographic images of the inferior midperipheral cornea were obtained at baseline and at 5, 15, 30, 60, 90, and 120 min after the instillation of 3% diquafosol ophthalmic solution in 10 Japanese white rabbits wearing contact lenses. From the obtained images, the areas of the PLTF and PoLTF were calculated. Both artificial tear solution and 0.1% sodium hyaluronate ophthalmic solution were used for comparison. Significant fluid accumulation in both the PLTF and PoLTF was observed after diquafosol instillation, whereas no fluid accumulation was visible after the instillation of artificial tear or sodium hyaluronate. The increase in PLTF area after diquafosol instillation was significantly higher (Pophthalmic solution increases PLTF and PoLTF in rabbit eyes with contact lenses. Diquafosol has potential as a treatment option for contact lens-related dry eye.

  16. A European perspective on costs and cost effectiveness of ophthalmic combinations in the treatment of open-angle glaucoma

    DEFF Research Database (Denmark)

    Hommer, A.; Thygesen, J.; Ferreras, A.

    2008-01-01

    PURPOSE: Efficacy, safety, and cost implications are important considerations when choosing an ophthalmic treatment. Fixed-combination glaucoma medications containing brimonidine 0.2% and timolol 0.5%, or dorzolamide 2% and timolol 0.5%, were compared with brimonidine 0.2% and dorzolamide 2...

  17. Bimatoprost 0.03%/timolol 0.5% preservative-free ophthalmic solution versus bimatoprost 0.03%/timolol 0.5% ophthalmic solution (Ganfort) for glaucoma or ocular hypertension: a 12-week randomised controlled trial

    Science.gov (United States)

    Goldberg, Ivan; Gil Pina, Rafael; Lanzagorta-Aresti, Aitor; Schiffman, Rhett M; Liu, Charlie; Bejanian, Marina

    2014-01-01

    Aim To compare the efficacy and safety of single-dose bimatoprost 0.03%/timolol 0.5% preservative-free (PF) ophthalmic solution with bimatoprost 0.03%/timolol 0.5% ophthalmic solution in patients with open-angle glaucoma or ocular hypertension. Methods In this multicentre, randomised, parallel-group study, patients were randomised to bimatoprost/timolol PF or bimatoprost/timolol once daily in the morning for 12 weeks. Primary efficacy endpoints, reflecting differing regional regulatory requirements, included change from baseline in worse eye intraocular pressure (IOP) in the per-protocol population at week 12, and the average eye IOP at weeks 2, 6 and 12 in the intent-to-treat population. Results 561 patients were randomised (278 to bimatoprost/timolol PF; 283 to bimatoprost/timolol); 96.3% completed the study. Both treatment groups showed statistically and clinically significant mean decreases from baseline in worse eye IOP and in average eye IOP at all follow-up time points (p<0.001). Bimatoprost/timolol PF met all pre-established criteria for non-inferiority and equivalence to bimatoprost/timolol. Ocular adverse events were similar between treatment groups, with conjunctival hyperaemia being the most frequent. Most were mild or moderate in severity. Conclusions Bimatoprost/timolol PF demonstrated non-inferiority and equivalence in IOP lowering compared with bimatoprost/timolol, with no significant differences in safety and tolerability. Trial registration number NCT01177098. PMID:24667994

  18. Imaging of Dual Ophthalmic Arteries: Identification of the Central Retinal Artery

    Directory of Open Access Journals (Sweden)

    Louise Louw

    2014-01-01

    Full Text Available Identification of the origin of the central retinal artery (CRA is imperative in tailoring angiographic studies to resolve a given clinical problem. A case with dual ophthalmic arteries (OAs, characterized by different origins and distinct branching patterns, is documented for training purposes. Pre-clinical diagnosis of a 9-year-old child who presented with a sharp wire in the left-side eyeball was primarily corneal laceration. For imaging, a selected six-vessel angiographic study with the transfemoral approach was performed. Embolization was not required and the wire could be successfully removed. Right-side OA anatomy was normal, while left-side dual OAs with external carotid artery (ECA and internal carotid artery (ICA origins were seen. The case presented with a left-side meningo-ophthalmic artery (M-OA anomaly via the ECA, marked by a middle meningeal artery (MMA (origin: Maxillary artery; course: Through foramen spinosum with normal branches (i.e. anterior and posterior branches, and an OA variant (course: Through superior orbital fissure with a distinct orbital branching pattern. A smaller OA (origin: ICA; course: Through optic foramen with a distinct ocular branching pattern presented with the central retinal artery (CRA. The presence of the dual OAs and the M-OA anomaly can be explained by disturbed evolutionary changes of the primitive OA and stapedial artery during development. The surgical interventionist must be aware of dual OAs and M-OA anomalies with branching pattern variations on retinal supply, because of dangerous extracranial-intracranial anastomotic connections. It is of clinical significance that the origin of the CRA from the ICA or ECA must be determined to avoid complications to the vision.

  19. Optimization of sup 125 I ophthalmic plaque brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Astrahan, M.A.; Luxton, G.; Jozsef, G.; Liggett, P.E.; Petrovich, Z. (Univ. of Southern California School of Medicine, Los Angeles (USA))

    1990-11-01

    Episcleral plaques containing {sup 125}I sources are often used in the treatment of ocular melanoma. Within four years post-treatment, however, the majority of patients experience some visual loss due to radiation retinopathy. The high incidence of late complications suggests that careful treatment optimization may lead to improved outcome. The goal of optimization would be to reduce the magnitude of vision-limiting complications without compromising tumor control. We have developed a three-dimensional computer model for ophthalmic plaque therapy which permits us to explore the potential of various optimization strategies. One simple strategy which shows promise is to maximize the ratio of dose to the tumor apex (T) compared to dose to the macula (M). By modifying the parameters of source location, activity distribution, source orientation, and shielding we find that the calculated T:M ratio can be varied by a factor of 2 for a common plaque design and posterior tumor location. Margins and dose to the tumor volume remain essentially unchanged.

  20. Triple-A syndrome with prominent ophthalmic features and a novel mutation in the AAAS gene: a case report

    Directory of Open Access Journals (Sweden)

    Stuart Caroline

    2004-06-01

    Full Text Available Abstract Background Triple-A syndrome (Allgrove syndrome is an autosomal recessive disorder characterized by adrenal insufficiency, alacrima, achalasia, and – occasionally – autonomic instability. Mutations have been found in the AAAS gene on 12q13. Case presentation We present the case of a 12 year-old boy with classic systemic features of triple-A syndrome and several prominent ophthalmic features, including: accommodative spasm, dry eye, superficial punctate keratopathy, and pupillary hypersensitivity to dilute pilocarpine. MRI showed small lacrimal glands bilaterally. DNA sequencing of PCR-amplified fragments from the 16 exons of the AAAS gene revealed compound heterozygosity for a new, out-of-frame 5-bp deletion in exon 15, c1368-1372delGCTCA, and a previously-described nonsense mutation in exon 9, c938C>T, R286X. Conclusions In addition to known ophthalmic manifestations, triple-A syndrome can present with accommodative dysregulation and ocular signs of autonomic dysfunction.

  1. Health claims database study of cyclosporine ophthalmic emulsion treatment patterns in dry eye patients

    OpenAIRE

    Stonecipher, Karl G; Chia, Jenny; Onyenwenyi, Ahunna; Villanueva, Linda; Hollander, David A

    2013-01-01

    Karl G Stonecipher,1 Jenny Chia,2 Ahunna Onyenwenyi,2 Linda Villanueva,2 David A Hollander2 1TLC Laser Eye Centers, Greensboro, NC, 2Allergan, Inc., Irvine, CA, USA Background: Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis®) use in dry eye patients and determine if there were any differences in use based o...

  2. Effect of vitamin A palmitate ophthalmic gel adjunctive therapy on tear film stability and inflammatory cytokines in patients with dry eye

    Directory of Open Access Journals (Sweden)

    Ya-Yuan Lu

    2018-06-01

    Full Text Available AIM:To investigate the effect of sodium hyaluronate eye drops combined with vitamin A palmitate ophthalmic gel on levels of tear film stability and inflammatory cytokines in patients with dry eye. METHODS: A total of 100 patients with dry eye treated in our hospital from January 2015 to February 2017 were randomly divided into control group and observation group, 50 cases in each group. Patients in the control group were treated with sodium hyaluronate eye drops. Patients in the observation group were given vitamin A palmitate ophthalmic gel on the basis of the control group, and then the clinical efficacy, tear film stability and the level of inflammatory cytokines were detected in the two groups. RESULTS: After treatment, the levels of BUT and SⅠt in both groups increased significantly compared with that before treatment, and FL was significantly lower than that before treatment. The levels of BUT and SⅠt in the observation group after treatment were 11.24±0.22s and 11.4±0.17mm/5min respectively, which was high than that of control groups(PPPPCONCLUSION: Sodium hyaluronate eye drops combined with vitamin A palmitate ophthalmic gel can relieve the symptoms of patients with dry eye effectively, increase the stability of tear film, and reduce the levels of inflammatory factors in tears, which is reliable in clinical application.

  3. Reduced in vivo ocular surface toxicity with polyquad-preserved travoprost versus benzalkonium-preserved travoprost or latanoprost ophthalmic solutions.

    Science.gov (United States)

    Liang, Hong; Brignole-Baudouin, Françoise; Riancho, Luisa; Baudouin, Christophe

    2012-01-01

    The study used a validated acute in vivo model to compare a new formulation of travoprost 0.004% ophthalmic solution(travoprost PQ), preserved with polyquaternium-1 (PQ), with commercially available formulations of benzalkonium-chloride(BAK)-preserved travoprost 0.004% ophthalmic solution(travoprost BAK) and BAK-preserved latanoprost 0.005%ophthalmic solution (latanoprost BAK). Adult male New Zealand albino rabbits (n = 36) were randomly divided into 6 groups. Phosphate-buffered saline (PBS), 0.001% PQ, 0.015% BAK, travoprost PQ, travoprost BAK or latanoprost BAK were applied onto rabbit eyes as 1 drop, for 15 times at 5-min intervals.The ocular surface reactions were investigated at hour 4 and day 1 using slitlamp examination; in vivo confocal microscopy (IVCM) for cornea, limbus and conjunctiva/conjunctiva-associated lymphoid tissue, conjunctival impression cytology and standard immunohistology in cryosections for detecting CD45+ infiltrating cells and MUC-5AC-labeled cells. PBS, PQ and travoprost PQ did not induce obvious irritation by clinical observation, changes in microstructures of the whole ocular surface as measured by IVCM analysis,inflammatory infiltration or cell damage as measured by impression cytology, altered levels of goblet cell counts or numerous CD45+ cells in the cornea. In contrast, all BAK-containing products induced diffuse conjunctival hyperemia and chemosis, abnormal changes in the ocular surface microstructure,significant total ocular surface toxicity scores,damaged epithelial cells, inflammatory cell infiltration and decreased goblet cell density. Travoprost PQ did not elicitocular surface toxicity when administered to rabbit eyes.These results suggest a greater safety advantage for the ocular surface of patients receiving chronic glaucoma treatment with PQ-preserved drugs.

  4. Bimatoprost 0.03%/timolol 0.5% preservative-free ophthalmic solution versus bimatoprost 0.03%/timolol 0.5% ophthalmic solution (Ganfort) for glaucoma or ocular hypertension: a 12-week randomised controlled trial.

    Science.gov (United States)

    Goldberg, Ivan; Gil Pina, Rafael; Lanzagorta-Aresti, Aitor; Schiffman, Rhett M; Liu, Charlie; Bejanian, Marina

    2014-07-01

    To compare the efficacy and safety of single-dose bimatoprost 0.03%/timolol 0.5% preservative-free (PF) ophthalmic solution with bimatoprost 0.03%/timolol 0.5% ophthalmic solution in patients with open-angle glaucoma or ocular hypertension. In this multicentre, randomised, parallel-group study, patients were randomised to bimatoprost/timolol PF or bimatoprost/timolol once daily in the morning for 12 weeks. Primary efficacy endpoints, reflecting differing regional regulatory requirements, included change from baseline in worse eye intraocular pressure (IOP) in the per-protocol population at week 12, and the average eye IOP at weeks 2, 6 and 12 in the intent-to-treat population. 561 patients were randomised (278 to bimatoprost/timolol PF; 283 to bimatoprost/timolol); 96.3% completed the study. Both treatment groups showed statistically and clinically significant mean decreases from baseline in worse eye IOP and in average eye IOP at all follow-up time points (p<0.001). Bimatoprost/timolol PF met all pre-established criteria for non-inferiority and equivalence to bimatoprost/timolol. Ocular adverse events were similar between treatment groups, with conjunctival hyperaemia being the most frequent. Most were mild or moderate in severity. Bimatoprost/timolol PF demonstrated non-inferiority and equivalence in IOP lowering compared with bimatoprost/timolol, with no significant differences in safety and tolerability. NCT01177098. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Evaluation of dacryocystorhinostomy using optical coherence tomography and rebamipide ophthalmic suspension

    Directory of Open Access Journals (Sweden)

    Fujimoto M

    2014-08-01

    Full Text Available Masahiro Fujimoto,1 Ken Ogino,1 Chika Miyazaki,1,2 Miou Hirose,1,3 Hiroko Matsuyama,1,4 Takeshi Moritera,1,5 Nagahisa Yoshimura1 1Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan; 2Department of Ophthalmology, Hyogo Prefectural Tsukaguchi Hospital, Hyogo, Japan; 3Department of Ophthalmology, Hyogo Prefectural Amagasaki Hospital, Hyogo, Japan; 4Department of Ophthalmology, National Hospital Organization Himeji Medical Center, Hyogo, Japan; 5Moritera Eye Clinic, Shiga, Japan Purpose: To evaluate the surgical outcome of dacryocystorhinostomy (DCR by measuring the tear meniscus, using optical coherence tomography and rebamipide ophthalmic suspension. Methods: Patients with nasolacrimal obstruction and chronic dacryocystitis who were scheduled for an endonasal DCR underwent tear meniscus examinations before and 2 months after surgery. Vertical scans of the inferior menisci were performed before and at 1, 3, 5, 7, and 10 minutes after the instillation of rebamipide ophthalmic suspension. The tear menisci areas were measured with imaging software. Ten young adults without epiphora formed the control group.Results: Anatomical success was achieved on 22 sides of 21 patients. The patients’ postoperative tear menisci were significantly smaller than the preoperative menisci at all points during the test, and the response to volume loading in the postoperative patients was corrected to nearly that of the young, healthy adults. Nevertheless, the postoperative meniscus area tended to be larger than that of the young adults at all points.Conclusion: The reduced tear meniscus area after DCR reflected the success of the surgical procedure. However, incomplete recovery of the meniscus after the test might suggest a residual disorder of the lacrimal drainage system after DCR. Keywords: dacryocystorhinostomy, tear meniscus, rebamipide, optical coherence tomography

  6. Herpes simplex virus ophthalmic disease induced using two different methods of mice inoculation

    Directory of Open Access Journals (Sweden)

    Sílvia Regina Ferreira Gonçalves Pereira

    Full Text Available Two different procedures for inoculation of HSV on corneas of BALB/c mice were evaluated. The first was by the use of HSV suspensions directly on the corneas and the other was after corneal scarification. Animals by this later method presented greater morbidity and mortality than those of first group, suggesting that inoculation of HSV without scarification of the cornea should be the method of choice for the study of HSV ophthalmic infection. This model showed also be an efficient experimental system to testing antiviral drugs.

  7. Preparation and In Vitro/Ex Vivo Evaluation of Moxifloxacin-Loaded PLGA Nanosuspensions for Ophthalmic Application.

    Science.gov (United States)

    Mudgil, Meetali; Pawar, Pravin K

    2013-01-01

    The aim of the present investigation was to prepare a colloidal ophthalmic formulation to improve the residence time of moxifloxacin. Moxifloxacin-loaded poly(dl-lactide-co-glycolide) (PLGA) nanosuspensions were prepared by using the solvent evaporation technique. The nanosuspensions were characterised physically by using different techniques like particle size, zeta potential, FTIR, DSC, and XRD analysis. In vitro and ex vivo studies of nanosuspensions were carried out using a modified USP dissolution apparatus and all-glass Franz diffusion cells, respectively. The antibacterial activities of the nanosuspension and marketed formulations were performed against S. aureus and P. aeroginosa. The moxifloxacin-loaded PLGA nanosuspensions showed uniform particle size, ranging between 164-490 nm with negative zeta potential for all batches. The percentage entrapment efficiency of the drug-loaded nano-suspension was found to be between 84.09 to 92.05%. In vitro drug release studies suggest that all of the formulations showed extended drug release profiles and follow Korsemeyer-Peppas release kinetics. In vitro corneal permeability was found to be comparable with that of the marketed formulation across isolated goat cornea, indicating the suitability of the nanosuspension formulation in the ophthalmic delivery of moxifloxacin. The optimised nano-suspension was found to be more active against S. aureus and P. aeruginosa compared to the marketed eye drops.

  8. Preparation and In Vitro/Ex Vivo Evaluation of Moxifloxacin-Loaded PLGA Nanosuspensions for Ophthalmic Application

    OpenAIRE

    MUDGIL, Meetali; PAWAR, Pravin

    2013-01-01

    The aim of the present investigation was to prepare a colloidal ophthalmic formulation to improve the residence time of moxifloxacin. Moxifloxacin-loaded poly(dl-lactide-co-glycolide) (PLGA) nanosuspensions were prepared by using the solvent evaporation technique. The nanosuspensions were characterised physically by using different techniques like particle size, zeta potential, FTIR, DSC, and XRD analysis. In vitro and ex vivo studies of nanosuspensions were carried out using a modified USP d...

  9. JPEG and wavelet compression of ophthalmic images

    Science.gov (United States)

    Eikelboom, Robert H.; Yogesan, Kanagasingam; Constable, Ian J.; Barry, Christopher J.

    1999-05-01

    This study was designed to determine the degree and methods of digital image compression to produce ophthalmic imags of sufficient quality for transmission and diagnosis. The photographs of 15 subjects, which inclined eyes with normal, subtle and distinct pathologies, were digitized to produce 1.54MB images and compressed to five different methods: (i) objectively by calculating the RMS error between the uncompressed and compressed images, (ii) semi-subjectively by assessing the visibility of blood vessels, and (iii) subjectively by asking a number of experienced observers to assess the images for quality and clinical interpretation. Results showed that as a function of compressed image size, wavelet compressed images produced less RMS error than JPEG compressed images. Blood vessel branching could be observed to a greater extent after Wavelet compression compared to JPEG compression produced better images then a JPEG compression for a given image size. Overall, it was shown that images had to be compressed to below 2.5 percent for JPEG and 1.7 percent for Wavelet compression before fine detail was lost, or when image quality was too poor to make a reliable diagnosis.

  10. ANALYSIS OF BETAMETHASONE DISODIUM PHOSPHATE INJECTION AND OPHTHALMIC SOLUTION BY HPLC, KINETIC INTERPRETATION AND DETERMINATION OF SHELF LIFE

    Directory of Open Access Journals (Sweden)

    A. Ghanbarpour

    1994-07-01

    Full Text Available Corticosteroids are widely used in therapeutics in different formulations. Betamethasone disodium phosphate is one of the most soluble of the adrenocorticosteroidal agents. It is therefore very suitable for intravenous use and particularly for ophthalmic formulations."nAcceleration method is used to determine expiration date of aqueous formulations manufactured in Iran.

  11. Dendritiform Keratopathy Associated with Exposure to Polyquarternium-1, a Common Ophthalmic Preservative.

    Science.gov (United States)

    Matoba, Alice Y; Peterson, Jeff R; Wilhelmus, Kirk R

    2016-03-01

    To describe dendritiform keratopathy associated with exposure to polyquaternium-1, a common preservative found in contact lens solutions and tear replacement products. Case series. Sixteen patients who demonstrated dendritiform keratopathy during topical ophthalmic exposure to polyquaternium-1. Records were reviewed of all patients diagnosed with dendritiform keratopathy between 1999 and 2014 who had documented exposure to contact lens care disinfecting solutions or artificial tear solutions containing polyquaternium-1. Patients were excluded who had coexisting potential causes for dendritiform keratopathy, such as prior herpes simplex keratitis, varicella-zoster viral keratitis, the linear form of Thygeson's superficial keratitis, epithelial regeneration line, Acanthamoeba keratitis, mucus plaque keratopathy, medication-related keratopathy, or limbal stem cell deficiency characterized by conjunctivalization of the corneal epithelium. Effect of discontinuation of exposure to polyquaternium-1 on the dendritiform keratopathy. Sixteen patients demonstrated dendritiform keratopathy after exposure to the preservative polyquaternium-1. Thirteen patients had a history of recent exposure to contact lens disinfecting solutions (Opti-Free, Equate) containing polyquaternium-1. Three patients used a tear replacement product (Systane) containing a polyquaternium-1 preservative. Four patients were treated with antiviral medications for presumed herpes simplex keratitis; 4 patients underwent diagnostic testing for Acanthamoeba keratitis. Two additional patients were diagnosed sequentially with herpes simplex keratitis, then Acanthamoeba keratitis before referral. All dendritiform lesions resolved within 2 to 6 weeks after elimination of exposure to polyquaternium-1. Ophthalmic products containing polyquaternium-1 may cause dendritiform keratopathy that may be confused with infections of the superficial cornea, such as herpes simplex virus keratitis or Acanthamoeba keratitis

  12. Comparative Evaluation of Ultraviolet and Visible Light Transmittance through Prescriptive Ophthalmic Minus Lenses

    Directory of Open Access Journals (Sweden)

    Mohammadreza Nazari

    2014-06-01

    Full Text Available Background: Wearing spectacles is the most common approach in correcting the refractive errors worldwide. Due to harmful effects of overexposure to solar ultraviolet radiations, the usage of multi-layer coatings in ophthalmic lenses has recently been increased. These lenses can reduce the reflections and hence increase the transmission of visible light; they can also decrease the transmission of ultraviolet rays. This study aims to compare the transmission of ultraviolet (A and B and visible rays through coated and uncoated prescriptive ophthalmic plastic lenses.Materials and Methods: In this study, 39 minus non-photochromic multi-coated white plastic single-vision lenses; 9 similar lenses but without any coatings were assessed by spectral transmittancemeter for evaluation of the transmission of visible and ultraviolet rays.Results: The transmission of visible light was 97.9%±1.07% for coated lenses and 93.5%±0.54% for lenses without coating. Ultraviolet-A transmission was 12.15%±8.02% for coated lenses compared to 66.27%±23.92% in lenses without coating. The transmission of ultraviolet-B rays was 1.21%±0.4% and 23.0%±15.97% for lenses with and without coatings, respectively.Conclusion: The transmission of visible light was significantly higher in multi-coated lenses compared to uncoated samples; whereas the transmissions of ultraviolet rays in multi-coated lenses were significantly lower than uncoated ones. Therefore, it is recommended that, except for particular cases, prescribed lenses be equipped with this multi-layer coating.

  13. Comfort level of post graduate residents working in different clinical domains in managing common ophthalmic conditions

    International Nuclear Information System (INIS)

    Jaffar, S.; Tayyab, A.; Shah, S.S.; Naseem, S.; Ghazanfar, H.

    2016-01-01

    Background: Ophthalmological conditions are frequently encountered in almost all clinical specialties. Assessing the adequacy of ophthalmology teaching in undergraduate medical education is important in order to diagnose and manage different ophthalmological conditions. The objective of this study was to determine the comfort level of post graduate residents working in different clinical domains in managing common ophthalmic conditions. Methods: A cross sectional survey involving 277 post graduate residents was carried out over a period of six months in both private and public tertiary care hospital. A questionnaire containing two sections and 17 variables in total were distributed among Medical Residents of different specialties except ophthalmology residents. Participants of the study were selected through consecutive non probability sampling. Results: Mean hours of classroom based ophthalmology instruction during during undergraduate program was 59.38 hours (55.9) and mean hours of clinical based ophthalmology instruction during undergraduate program was 62.73 hours (60.8) 54 percentage were either not comfortable or somewhat comfortable in managing common ophthalmic condition. Conclusion: Teaching hours in under graduate program meet or exceed requisite criteria. However graduating doctors generally feel that the time spent does not provide them with the comfort and skill level required to care for patients with ocular presentations. (author)

  14. Cysteamine ophthalmic hydrogel for the treatment of ocular cystinosis

    Directory of Open Access Journals (Sweden)

    Anxo Fernández-Ferreiro

    2017-11-01

    Full Text Available Ocular cystinosis is a rare disease characterised by the deposit of cystine crystals on the corneal surface, which hinder patients’ eyesight. Oral cysteamine is given as cysteamine; however, it does not reach the cornea due to the lack of corneal vascularization making necessary its administration by the topical ocular route. The aim of the present study is to determine the stability of an ophthalmic hydrogel of cysteamine, which can be potentially prepared at hospital pharmacy departments, under different preservation conditions during a follow-up of 30 days. Different physical and chemical parameters were evaluated: osmolality, pH and cysteamine concentration, which has been measured by a method of ultra performance liquid chromatography-tandem mass spectrometer (UPLC-MS/MS. Descriptive assays were also performed, such as transparency measurement and microbiological assays in order to verify its sterility. The obtained results allow us to conclude that the cysteamine hydrogel is stable during 30 days, being recommendable its preservation in refrigerated conditions.

  15. Persistent dorsal ophthalmic artery arising from the internal carotid artery: Report of three cases

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jae Hwan; Lee, Ghi Jai; Shim, Jae Chan; Lee, Kyoung Eun; Kim, Ho Kyun; Suh, Jung Ho [Dept. of Radiology, Seoul Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    Normally, the ophthalmic artery (OA) arises from the supraclinoid segment of the internal carotid artery (ICA) and enters the orbit via the optic canal. A persistent dorsal OA is a rare variation that originates from the cavernous segment of the ICA and enters the orbit via the superior orbital fissure. To the best of our knowledge, persistent dorsal OA has not been described in the Korean literature. In this paper, we report three cases of persistent dorsal OA with review of the literature on embryogenesis and other origins of the OA.

  16. Effect of diquafosol three per cent ophthalmic solution on tear film and corneal aberrations after cataract surgery.

    Science.gov (United States)

    Lee, Hun; Kim, Sang Myung; Choi, Seonghee; Seo, Kyoung Yul; Kim, Eung Kweon; Kim, Tae-Im

    2017-11-01

    The aim was to evaluate the effect of diquafosol on tear film parameters and corneal aberrations after cataract surgery. This retrospective, comparative, observational case series included patients who underwent cataract surgery with or without peri-operative use of diquafosol three per cent ophthalmic solution. Patients in group I (31 eyes) were treated with diquafosol three per cent ophthalmic solution six times a day from one week before surgery to three months after surgery. Patients in group II (33 eyes) underwent cataract surgery without being administered diquafosol. Tear film break-up time (BUT), the ocular surface disease index (OSDI), the Oxford Scheme score, Schirmer's test I and corneal aberrations were determined before and at one and three months post-surgery. In group I, the BUT, OSDI and Oxford Scheme score showed significant improvement at one and three months post-surgery (p = 0.002 for BUT at one month and three months, p = 0.023 and p = 0.049 for OSDI at one month and three months and p = 0.001 and p = 0.026 for Oxford Scheme at one month and three months), compared to baseline. In group II, the BUT, OSDI and Oxford Scheme score did not show any significant improvement during the follow-up period. In both groups, Schirmer's test I significantly decreased at three months post-surgery (p = 0.011 for group I and p = 0.034 for group II), compared to baseline. There were significant differences in the BUT and OSDI between the groups at three months post-surgery (p = 0.037 for BUT and p = 0.011 for OSDI). Regarding the corneal aberration, there were no significant differences between the groups at three months post-surgery. Peri-operative application of diquafosol three per cent ophthalmic solution may prevent dry eye-related ocular surface changes accompanied by improvement of ocular symptom. No definite changes in corneal aberrations were noted. © 2017 Optometry Australia.

  17. The superior ophthalmic vein approach for the treatment of carotid-cavernous fistulas: our first experience

    Directory of Open Access Journals (Sweden)

    Chiriac A.

    2016-06-01

    Full Text Available Complex cavernous sinus fistulae (CCF are still a technical challenge to neurovascular team. The most commonly performed treatment consists in endovascular embolization of the lesion through an arterial or venous approach. Not always these conventional routes are feasible, requiring alternative routes. We report a case of a 44-year-old woman with a complex indirect (Barrow D carotid cavernous sinus fistula treated by two interventional sessions that imposing a retrograde direct transvenous approach via the superior ophthalmic vein.

  18. Formulation and development of ophthalmic in situ gel for the treatment ocular inflammation and infection using application of quality by design concept.

    Science.gov (United States)

    Patel, Nirav; Thakkar, Vaishali; Metalia, Viral; Baldaniya, Lalji; Gandhi, Tejal; Gohel, Mukesh

    2016-09-01

    The conventional liquid ophthalmic delivery systems exhibit short pre-corneal residence time and the relative impermeability to the cornea which leads to poor ocular bioavailability. The aim of this study was to apply quality by design (QbD) for development of dexamethasone sodium phosphate (DSP) and tobramycin sulfate (TS)-loaded thermoresponsive ophthalmic in situ gel containing Poloxamer 407 and hydroxyl propyl methyl cellulose (HPMC) K4M for prolonging the pre-corneal residence time, ocular bioavability and decreases the frequency of administration of dosage form. The material attributes and the critical quality attributes (CQA) of the in situ gel were identified. Central composite design (CCD) was adopted to optimize the formulation. The ophthalmic in situ forming gels were prepared by cold method. Materials attributes were the amount of Poloxamer 407 and HPMC and CQA identified were Gel strength, mucoadhesive index, gelation temperature and % of drug release of both drug. Optimized batch (F*) containing 16.75% poloxamer 407 and 0.54% HPMC K4M were exhibited all results in acceptable limits. Compared with the marketed formulation, optimized in situ gel showed delayed Tmax, improved Cmax and AUC in rabbit aqueous humor, suggesting the sustained drug release and better corneal penetration and absorption. According to the study, it could be concluded that DSP and TS would be successfully formulated as in situ gelling mucoadhesive system for the treatment of steroid responsive eye infections with the properties of sustained drug release, prolonged ocular retention and improved corneal penetration.

  19. Stability study of azithromycin in ophthalmic preparations

    Directory of Open Access Journals (Sweden)

    Andréia de Haro Moreno

    2009-06-01

    Full Text Available A stability study of azithromycin in ophthalmic preparations was developed by submission to different types of light, temperature and pH, using the biodiffusion assay (cylinder 3 x 3 for the quantifications. Bacillus subtilis, ATCC 9372, was used as test organism. The used concentration range was of 50 to 200 µg/mL. The study demonstrated that the drug suffered degradation when submitted to the ultraviolet light, germicide light, solar luminosity, acid solution, basic solution and hydrogen peroxide solution. The results were analyzed by the analysis of variance (ANOVA.O estudo de estabilidade de azitromicina em preparações oftálmicas foi realizado após exposição a diferentes tipos de luz, temperatura e pH, utilizando o método de difusão em ágar (cilindros 3 x 3 para as quantificações. A faixa de concentração foi de 50 a 200 µg/mL. O estudo demonstrou que o fármaco sofreu degradação quando submetido às luzes ultravioleta, germicida e solar, e a soluções ácida, alcalina e de peróxido de hidrogênio. Os resultados foram analisados através da análise da variância (ANOVA.

  20. 21 CFR 886.4610 - Ocular pressure applicator.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4610 Ocular pressure applicator. (a... bulb, a dial indicator, a band, and bellows, intended to apply pressure on the eye in preparation for...

  1. 76 FR 80949 - Request for Nominations for Voting Members on Public Advisory Panels or Committees

    Science.gov (United States)

    2011-12-27

    .... Orthopedic and Rehabilitation Devices Panel. Jamie Waterhouse, Center for Devices Circulatory System Devices... Advisory Committee--Neurosurgeons (cerebrovascular and pediatric), neurologists (stroke, pediatric, pain... ophthalmic clinical trials. Orthopaedic and 2 September 1, 2012. Rehabilitation Devices Panel of the Medical...

  2. New developments in ophthalmic coatings on plastic lenses

    Science.gov (United States)

    Eigenmann, H. P.; Lobsiger, W.; Suter, R.

    1998-02-01

    The origin of vision aids such as eyeglasses, magnifying glasses, telescopes and so forth lies in the distant past and cannot be dated with precision. However, such aids certainly came into use at different times in different cultures. Early portraits and other pictures prove to a certainty, however, that remarkable well-made spectacles were in use by the end of the Middle Ages. Glass was employed for optical lenses from the very beginning, and quality improved continuously with advances in glassmaking and polishing techniques. Starting around 1970, this continuing development received new impetus from the introduction of plastics as a new material for ophthalmic lenses. Rapid progress in plastics chemistry had epoch-making effects on lens technology, and today a wide variety of materials such as CR39, PMMA and polycarbonates, with refractive indices ranging from 1.52 to 1.65, are used for this purpose. Eyeglasses have long been important on other grounds than vision correction; people wear them as adornment, because they are fashionable, to express their personality, and for other reasons. This dramatic history shows no signs of coming to an end, and more innovations are definitely ahead.

  3. A randomised, double-masked comparison study of diquafosol versus sodium hyaluronate ophthalmic solutions in dry eye patients.

    Science.gov (United States)

    Takamura, Etsuko; Tsubota, Kazuo; Watanabe, Hitoshi; Ohashi, Yuichi

    2012-10-01

    To compare the efficacy and safety of 3% diquafosol ophthalmic solution with those of 0.1% sodium hyaluronate ophthalmic solution in dry eye patients, using mean changes in fluorescein and rose bengal staining scores as endpoints. TRIAL DESIGN AND METHODS: In this multicenter, randomised, double-masked, parallel study of 286 dry eye patients with fluorescein and rose bengal staining scores of ≥3 were randomised to the treatment groups in a 1 : 1 ratio. Efficacy and safety were evaluated after drop-wise instillation of the study drug, six times daily for 4 weeks. After 4 weeks, the intergroup difference in the mean change from baseline in fluorescein staining score was -0.03; this verified the non-inferiority of diquafosol. The mean change from baseline in rose bengal staining score was significantly lower in the diquafosol group (p=0.010), thus verifying its superiority. The incidence of adverse events was 26.4% and 18.9% in the diquafosol and sodium hyaluronate groups, respectively, with no significant difference. Diquafosol (3%) and sodium hyaluronate (0.1%) exhibit similar efficacy in improving fluorescein staining scores of dry eye patients, whereas, diquafosol exhibits superior efficacy in improving rose bengal staining scores. Diquafosol has high clinical efficacy and is well tolerated with a good safety profile.

  4. Choosing wisely and the use of antibiotics in ophthalmic surgery: There is more than meets the eye.

    Science.gov (United States)

    Grosso, Andrea; Ceruti, Piero; Scarpa, Giuseppe; Giardini, Franco; Marchini, Giorgio; Aragona, Emanuela; Bert, Fabrizio; Bandello, Francesco; Siliquini, Roberta

    2018-02-01

    One of the directions of modern ophthalmology is toward an odontoiatric model, and new settings of eye care are becoming the standard of care: one day surgery and also office-based therapies. Retrospective analysis of three tertiary-care centers in Italy and analysis of the literature. We provide readers with state-of-the-art measures of prophylaxis in ophthalmic surgery. Role of antibiotics is criticized in the light of stewardship antimicrobial paradigm.

  5. Spring-action Apparatus for Fixation of Eyeball (SAFE): a novel, cost-effective yet simple device for ophthalmic wet-lab training.

    Science.gov (United States)

    Ramakrishnan, Seema; Baskaran, Prabu; Fazal, Romana; Sulaiman, Syed Mohammad; Krishnan, Tiruvengada; Venkatesh, Rengaraj

    2016-10-01

    Achieving a formed and firm eyeball which is stably fixed in a holding device is a major challenge of surgical wet-lab training. Our innovation, the 'Spring-action Apparatus for Fixation of Eyeball (SAFE)' is a robust, simple and economical device to solve this problem. It consists of a hollow iron cylinder to which a spring-action syringe is attached. The spring-action syringe generates vacuum and enables reliable fixation of a human or animal cadaveric eye on the iron cylinder. The rise in intraocular pressure due to vacuum fixation can be varied as per need or nature of surgery being practised. A mask-fixed version of this device is also designed to train surgeons for appropriate hand positioning. An experienced surgeon performed various surgeries including manual small incision cataract surgery (MSICS), phacoemulsification, laser in situ keratomileusis (LASIK), femtosecond LASIK docking, Descemet's stripping endothelial keratoplasty, deep anterior lamellar keratoplasty, penetrating keratoplasty and trabeculectomy on this device, while a trainee surgeon practised MSICS and wound suturing. Skill-appropriate comfort level was much higher with SAFE than with conventional globe holders for both surgeons. Due to its stability, pressure adjustability, portability, cost-efficiency and simplicity, we recommend SAFE as the basic equipment for every wet lab. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. 21 CFR 886.4400 - Electronic metal locator.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic foreign bodies in the eye or eye socket. (b) Classification. Class II. ...

  7. 21 CFR 886.1700 - Pupillometer.

    Science.gov (United States)

    2010-04-01

    ... eye. (b) Classification. Class I (general controls). The AC-powered device and the manual device are... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1700 Pupillometer. (a) Identification. A pupillometer is an AC...

  8. 21 CFR 886.1250 - Euthyscope.

    Science.gov (United States)

    2010-04-01

    ... disease of the eye). (b) Classification. Class I for the battery powered device. The battery powered... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1250 Euthyscope. (a) Identification. A euthyscope is a device...

  9. Ocular Tolerance of Contemporary Electronic Display Devices.

    Science.gov (United States)

    Clark, Andrew J; Yang, Paul; Khaderi, Khizer R; Moshfeghi, Andrew A

    2018-05-01

    Electronic displays have become an integral part of life in the developed world since the revolution of mobile computing a decade ago. With the release of multiple consumer-grade virtual reality (VR) and augmented reality (AR) products in the past 2 years utilizing head-mounted displays (HMDs), as well as the development of low-cost, smartphone-based HMDs, the ability to intimately interact with electronic screens is greater than ever. VR/AR HMDs also place the display at much closer ocular proximity than traditional electronic devices while also isolating the user from the ambient environment to create a "closed" system between the user's eyes and the display. Whether the increased interaction with these devices places the user's retina at higher risk of damage is currently unclear. Herein, the authors review the discovery of photochemical damage of the retina from visible light as well as summarize relevant clinical and preclinical data regarding the influence of modern display devices on retinal health. Multiple preclinical studies have been performed with modern light-emitting diode technology demonstrating damage to the retina at modest exposure levels, particularly from blue-light wavelengths. Unfortunately, high-quality in-human studies are lacking, and the small clinical investigations performed to date have failed to keep pace with the rapid evolutions in display technology. Clinical investigations assessing the effect of HMDs on human retinal function are also yet to be performed. From the available data, modern consumer electronic displays do not appear to pose any acute risk to vision with average use; however, future studies with well-defined clinical outcomes and illuminance metrics are needed to better understand the long-term risks of cumulative exposure to electronic displays in general and with "closed" VR/AR HMDs in particular. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:346-354.]. Copyright 2018, SLACK Incorporated.

  10. Development of an Iridium-192 seed for use in ophthalmic brachytherapy

    International Nuclear Information System (INIS)

    Mattos, Fabio R.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos; Moura, Joao A.; Costa, Osvaldo L.; Feher, Anselmo; Moura, Eduardo S.; Souza, Carla D.; Peleias Junior, Fernando S.

    2011-01-01

    The Institute for Energy and Nuclear Research (IPEN), in partnership with the School or Medicine (UNIFESP), created a project that aims to develop and implement an ophthalmic therapeutic treatment for cancer with Iridium-192 seeds. The School of Medicine treats many cancer cases in the SUS (Brazilian Public Health System), and brachytherapy group of IPEN has extensive experience in prototype sources. The seed to be manufactured will perform as follows: a core of Iridium-192 is packaged inside small cylindrical seeds consist of a titanium capsule of 0.8 mm outer diameter, 0.05 mm wall thickness and 4 5 mm in length. The core is an alloy of platinum-iridium (20/80) of 3.0 mm in length and 0.3 mm in diameter. Material analysis, neutron activation and activity measurements were carried out. (author)

  11. Post-marketing surveillance of levofloxacin 0.5% ophthalmic solution for external ocular infections.

    Science.gov (United States)

    Kanda, Yoshiko; Kayama, Tomoko; Okamoto, Shinji; Hashimoto, Masako; Ishida, Chiemi; Yanai, Tomoko; Fukumoto, Mitsuru; Kunihiro, Eiichi

    2012-12-01

    Levofloxacin 0.5% ophthalmic solution is an antibacterial formulation, which was approved and marketed for the treatment of ocular infections in Japan in 2000. This study was designed to investigate the safety and efficacy of levofloxacin 0.5% ophthalmic solution in patients who received treatment for external ocular bacterial infections in regular clinical practice. Patients were recruited from more than 800 medical facilities in Japan, in accordance with Japanese Ministry of Health, Labour and Welfare ordinance guidelines. They were followed during three distinct time periods: April 2000 to December 2001, January 2002 to June 2003, and July 2003 to December 2004. Information from 6760 patients receiving levofloxacin for the treatment of a variety of ocular infections was collected. Levofloxacin was well tolerated: adverse drug reactions (ADRs) were reported in 42 of 6686 patients (0.63%), with no serious ADRs reported. The most commonly reported ADRs were ocular disorders such as blepharitis, eye irritation, and punctate keratitis. The incidence of ADRs did not differ significantly with age, but it was significantly higher in females (0.82%) than in males (0.36%; p = 0.028). A clinical response was observed in 95.5% of patients receiving levofloxacin, with no difference in response between the three time periods. The rate of response to levofloxacin by bacterial disease ranged from 97.4% in keratitis to 88.3% in dacryocystitis. The rate was lower in patients with dacryocystitis, elderly patients, patients with a long duration of illness, and relapsing cases (all p marketing surveillance of levofloxacin, conducted over 4 years, confirms the safety and efficacy of levofloxacin in regular clinical use and highlights that levofloxacin is a promising treatment for a variety of external ocular bacterial infections.

  12. Multimodal ophthalmic imaging using spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography

    Science.gov (United States)

    El-Haddad, Mohamed T.; Malone, Joseph D.; Li, Jianwei D.; Bozic, Ivan; Arquitola, Amber M.; Joos, Karen M.; Patel, Shriji N.; Tao, Yuankai K.

    2017-08-01

    Ophthalmic surgery involves manipulation of delicate, layered tissue structures on milli- to micrometer scales. Traditional surgical microscopes provide an inherently two-dimensional view of the surgical field with limited depth perception which precludes accurate depth-resolved visualization of these tissue layers, and limits the development of novel surgical techniques. We demonstrate multimodal swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography (SS-SESLO-OCT) to address current limitations of image-guided ophthalmic microsurgery. SS-SESLO-OCT provides inherently co-registered en face and cross-sectional field-of-views (FOVs) at a line rate of 400 kHz and >2 GPix/s throughput. We show in vivo imaging of the anterior segment and retinal fundus of a healthy volunteer, and preliminary results of multi-volumetric mosaicking for ultrawide-field retinal imaging with 90° FOV. Additionally, a scan-head was rapid-prototyped with a modular architecture which enabled integration of SS-SESLO-OCT with traditional surgical microscope and slit-lamp imaging optics. Ex vivo surgical maneuvers were simulated in cadaveric porcine eyes. The system throughput enabled volumetric acquisition at 10 volumes-per-second (vps) and allowed visualization of surgical dynamics in corneal sweeps, compressions, and dissections, and retinal sweeps, compressions, and elevations. SESLO en face images enabled simple real-time co-registration with the surgical microscope FOV, and OCT cross-sections provided depth-resolved visualization of instrument-tissue interactions. Finally, we demonstrate novel augmented-reality integration with the surgical view using segmentation overlays to aid surgical guidance. SS-SESLO-OCT may benefit clinical diagnostics by enabling aiming, registration, and mosaicking; and intraoperative imaging by allowing for real-time surgical feedback, instrument tracking, and overlays of computationally extracted biomarkers of disease.

  13. A new method for characterizing beta-ray ophthalmic applicator sources

    International Nuclear Information System (INIS)

    Sayeg, J.A.; Gregory, R.C.

    1991-01-01

    A technique is described which enables one to obtain detailed dose characteristics of 90Sr beta-ray ophthalmic applicators. A radiochromic radiation detector which is a solid-state solution of hexahydroxyethyl pararosaniline cyanide in a nylon polymer (i.e., thin foil), has been used to determine the surface dose rate and dose distribution of these sources. The detectors are rugged, easily handled, have an equivalent response (optical density per unit absorbed dose) to photons and electrons, and produce high-resolution images. They have been found useful for this application due to the high surface dose rates [0.10-1.0 Gy (H2O)/s] and their low sensitivity (approximately 10(4) Gy for an optical density of 1.0). The foils have been evaluated on a He-Ne scanning laser densitometer with a resolution of 0.3 mum. Comparison with NIST (formerly NBS) extrapolation ionization chamber measurements indicates surface dose-rate agreement within 6%. Spectral dosimetric characteristics are presented and discussed

  14. 21 CFR 886.1660 - Gonioscopic prism.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber. The device may have angled mirrors to facilitate visualization of anatomical features. (b...

  15. Imaging of Unilateral Meningo-ophthalmic Artery Anomaly in a Patient with Bilateral Nasopharyngeal Angiofibroma

    Directory of Open Access Journals (Sweden)

    Louise Louw

    2014-01-01

    Full Text Available A 12-year-old boy with epistaxis presented with a rare midline nasopharyngeal angiofibroma that extended lateral into the pterygoid and infratemporal fossae. Pre-operative angiography revealed bilateral prominent feeder arteries and two major anastomotic connections, and a rare left meningo-ophthalmic artery (M-OA anomaly that was the sole path of supply to the eye. A literature search using Pubmed and Medline was conducted. For imaging, a six-vessel study (i.e. external and internal carotid and vertebral arteries on both sides was selected. Embolization of prominent tumor feeder arteries was unsafe for tumor extirpation, but super-selective embolization of both sphenopalatine arteries was performed to control epistaxis. The M-OA anomaly that originated from the maxillary artery (MA was marked by an ophthalmic artery (OA variant with orbital and ocular divisions that coursed through the superior orbital fissure and optic foramen, respectively, each with distinct branching patterns, a middle meningeal artery (MMA with normal branches (i.e. anterior and posterior branches, and two branch variations (i.e. lacrimal and meningeal branches that originated from the anterior branch of the MMA. The lacrimal branch coursed through a cranio-orbital foramen, but the meningeal branch remained outside the orbit. The anatomy of the right OA was normal. The left M-OA anomaly was considered incidental and not tumor-related since the tumor was more prominent on the right side, and no intra-orbital infiltrations occurred. Of clinical significance is that proximal embolization of MA or MMA carries a high risk of visual impairment in cases where M-OA anomalies are the sole mode of supply to the eye.

  16. Effect of topical ophthalmic dorzolamide(2%)-timolol(0.5%) solution and ointment on intraocular pressure in normal horses.

    Science.gov (United States)

    Tofflemire, Kyle L; Whitley, Elizabeth M; Flinn, Allison M; Dufour, Valerie L; Ben-Shlomo, Gil; Allbaugh, Rachel A; Griggs, Angela N; Peterson, Chimene S; Whitley, David R

    2015-11-01

    To compare the effect of commercially available solution and compounded ointment formulations of dorzolamide(2%)-timolol(0.5%) on intraocular pressure (IOP) of normal horses. Eighteen clinically normal horses. A randomized, masked prospective design was used with horses divided into two equal groups. One eye of each horse was selected for topical ophthalmic treatment with either 0.2 mL of dorzolamide(2%)-timolol(0.5%) solution or 0.2 g of dorzolamide(2%)-timolol(0.5%) ointment every 12 h for 5 days. The contralateral eye of horses in both groups was untreated. Rebound tonometry was performed every 6 h starting 2 days prior to and ending 2 days after the treatment period. The mean IOP reduction in eyes treated with the solution or ointment formulations was 13%. Untreated eyes in both groups experienced a lesser but still statistically significant reduction in IOP. The IOP values did not return to baseline within 48 h of the last treatment. The commercially available solution and compounded ointment formulations of ophthalmic dorzolamide(2%)-timolol(0.5%) had similar effects on IOP in normal horses. Persistent IOP reduction following cessation of treatment may indicate prolonged drug effect or acclimation of horses to tonometry. © 2014 American College of Veterinary Ophthalmologists.

  17. Comparative in vitro toxicology study of travoprost polyquad-preserved, travoprost BAK-preserved, and latanoprost BAK-preserved ophthalmic solutions on human conjunctival epithelial cells.

    Science.gov (United States)

    Brignole-Baudouin, Françoise; Riancho, Luisa; Liang, Hong; Baudouin, Christophe

    2011-11-01

    To compare the toxicological profile of a new formulation of travoprost 0.004% ophthalmic solution (travoprost PQ), containing the preservative polyquaternium-1(PQ, polyquad), with the commercially available formulation of benzalkonium chloride (BAK)-preserved travoprost 0.004% ophthalmic solution (travoprost BAK) and BAK-preserved latanoprost 0.005% ophthalmic solution (latanoprost BAK). Human conjunctival epithelial cells were incubated with phosphate-buffered saline (PBS), BAK 0.015%, BAK 0.020%, PQ 0.001%, travoprost PQ preserved with PQ 0.001%, travoprost preserved with BAK 0.015%, or latanoprost preserved with BAK 0.020%. Six toxicological assays were used to assess: cell viability (neutral red, Alamar blue), apoptosis (YO-PRO-1, Hoechst 33342), and oxidative stress (H(2)DCF-DA, hydroethidine). Apoptosis and oxidative stress were each reported according to cell viability as observed with neutral red and Alamar blue for a total of 10 analyses per treatment depending on the cell viability test used to interpret apoptosis and oxidative stress responses. There were no significant differences in toxicity between cells exposed to PBS and cells exposed to travoprost PQ (10/10 analyses) or PQ 0.001% (9/10 analyses). Ten out of 10 analyses revealed that travoprost PQ produced significantly less cytotoxicity than latanoprost BAK (p solution in 9 of 10 analyses (p < 0.0001). A panel of in vitro toxicity analyses supports the safety of travoprost PQ. Travoprost PQ may be better for ocular surface health than BAK-preserved formulations of latanoprost or travoprost but clinical studies are required to validate these comparisons.

  18. Ophthalmic diagnostic tests, orbital anatomy, and adnexal histology of the broad-snouted caiman (Caiman latirostris).

    Science.gov (United States)

    Oriá, Arianne P; Oliveira, Alberto Vinícius D; Pinna, Melissa H; Martins Filho, Emanoel F; Estrela-Lima, Alessandra; Peixoto, Tiago C; Silva, Renata Maria M da; Santana, Fernanda O; Meneses, Íris Daniela S; Requião, Kátia G; Ofri, Ron

    2015-01-01

    The aim of this study was to establish normal ophthalmic parameters for selected diagnostic tests, and to describe the orbital anatomy and adnexal histology of the broad-snouted caiman. A total of 35 Caiman latirostris that were free of obvious ocular diseases were used to measure the parameters in this investigation. Ages ranged from 5 to 15 years. Ophthalmic diagnostic tests were conducted, including evaluation of tear production with Schirmer Tear test-1 (STT1), culture of the conjunctival bacterial flora, applanation tonometry, conjunctival cytology, nictiating membrane incursion frequency test (NMIFT), endodontic absorbent paper point tear test (EAPPTT), palpebral fissure length measurement (PFL) and B-mode ultrasonography. Adnexal histology and skull samples were studied. Mean (±SD) STT1 was 3.4 ± 3.6 mm/min (95% confidence interval of 2.01-4.78 mm/min), intraocular pressure (IOP) was 12.9 ± 6.2 mmHg, NMIFT was 6.0 ± 3.5, EAPPTT was 17.1 ± 2.5 mm/min, PFL was 28.9 ± 3.0 mm, anterior chamber depth was 3.1 ± 0.3 mm, lens axial length was 8.4 ± 0.6 mm, vitreous chamber depth was 7.9 ± 0.7 mm and axial globe length was 19.9 ± 1.3 mm. For all animals evaluated, Bacillus sp., Diphteroids and Staphylococcus sp. were predominant. © 2013 American College of Veterinary Ophthalmologists.

  19. Observation on the availability and tolerance of 0.1% bromfenac sodium hydrate ophthalmic solution in the partial substitution of glucocorticoid after LASEK

    Directory of Open Access Journals (Sweden)

    Zhi-Hui Deng

    2015-12-01

    Full Text Available AIM:To observe the availability and tolerance of 0.1% bromfenac sodium hydrate ophthalmic solution in the partial substitution of glucocorticoid after laser subepithelial keratomileusis(LASEK. METHODS:Totally 180 patients(180 eyesreceived LASEK were selected and divided into study group and control group according to different medications. The study group adopted 0.1% bromfenac sodium hydrate ophthalmic solution combined with glucocorticoid; the control group adopted glucocorticoid. The changes of visual acuity and intraocular pressure(IOPof two groups were recorded before and after surgery and the occurrence of diffuse larnellar kerafitis(DLKafter surgery were observed. RESULTS:After 1mo of surgery, visual acuity of study group was 1.25±0.22 while that of control group was 0.97±0.23(PP>0.05. After 1 and 3mo of surgery, IOP of study group was 12.29±2.71 and 12.67±2.33mmHg while that of control group was 14.26±2.65 and 14.56±2.61mmHg, the difference was statistically significant(PP>0.05. In terms of tolerance, the control group had 4 cases(4 eyestaking the IOP-lowering medication. The study group had no uncomfortable cases. The DLK level of the study group at 0, 1, 2 was 93.33%, 6.67%, 0%, respectively and those in control group was 75.56%, 17.78% and 6.67%, respectively, and the differences were significant(PCONCLUSION:0.1% bromfenac sodium hydrate ophthalmic solution can efficiently stabilize the patient's IOP after LASEK. The patient has a better visual acuity, visual function and fewer complications. The tolerance is also favorable. It is worthy of promotion.

  20. Brachytherapy, diagnostic radiology, mammographic radiology and ophthalmic applicators. An assessment of current and future needs in the UK and the role of NPL

    International Nuclear Information System (INIS)

    Angliss, R.; Bass, G.; Sander, T.

    2001-01-01

    Several UK hospitals were visited by NPL staff to discuss the current practises and future developments in brachytherapy, diagnostic and mammographic radiology and ophthalmic applicators. The results of the discussions are presented here, including NPL's role in each of these areas is discussed. (author)

  1. 21 CFR 886.1870 - Stereoscope.

    Science.gov (United States)

    2010-04-01

    ... exercises of eye muscles. (b) Classification. Class I (general controls). The AC-powered device and the... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1870 Stereoscope. (a) Identification. A stereoscope is an AC...

  2. 21 CFR 886.1770 - Manual refractor.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1770 Manual refractor. (a) Identification. A manual refractor is a device that is a set of lenses of varous dioptric powers intended to measure the refractive error of the eye. (b) Classification. Class I (general controls). The device is exempt from the...

  3. Preparation and evaluation of a timolol maleate drug-resin ophthalmic suspension as a sustained-release formulation in vitro and in vivo.

    Science.gov (United States)

    Qin, Fuhong; Zeng, Li; Zhu, Yongtao; Cao, Jingjing; Wang, Xiaohui; Liu, Wei

    2016-01-01

    The aim of this work was to assess the performance of resin as an ocular delivery system. Timolol maleate (TM) was chosen as the model drug and an ion exchange resin (IER) as the carrier. The drug-resin complex was prepared using an oscillation method and then characterized regarding particle size, zeta potential, morphology, and drug content. After in vitro drug release study and corneal permeation study were performed, in vivo studies were performed in New Zealand albino rabbits using a suspension with particles sized 4.8 ± 1.2 μm and drug loading at 43.00 ± 0.09%. The results indicate that drug released from the drug-resin ophthalmic suspension permeated the cornea and displayed a sustained-release behavior. Drug levels in the ocular tissues after administration of the drug-resin ophthalmic suspension were significantly higher than after treatment with an eye drop formulation but were lower in body tissues and in the plasma. In conclusion, resins have great potential as effective ocular drug delivery carriers to increase ocular bioavailability of timolol while simultaneously reducing systemic drug absorption.

  4. Epigenetic Treatment of Neurodegenerative Ophthalmic Disorders: An Eye Toward the Future.

    Science.gov (United States)

    Moos, Walter H; Faller, Douglas V; Glavas, Ioannis P; Harpp, David N; Irwin, Michael H; Kanara, Iphigenia; Pinkert, Carl A; Powers, Whitney R; Steliou, Kosta; Vavvas, Demetrios G; Kodukula, Krishna

    2017-01-01

    Eye disease is one of the primary medical conditions that requires attention and therapeutic intervention in ageing populations worldwide. Further, the global burden of diabetes and obesity, along with heart disease, all lead to secondary manifestations of ophthalmic distress. Therefore, there is increased interest in developing innovative new approaches that target various mechanisms and sequelae driving conditions that result in adverse vision. The research challenge is even greater given that the terrain of eye diseases is difficult to landscape into a single therapeutic theme. This report addresses the burden of eye disease due to mitochondrial dysfunction, including antioxidant, autophagic, epigenetic, mitophagic, and other cellular processes that modulate the biomedical end result. In this light, we single out lipoic acid as a potent known natural activator of these pathways, along with alternative and potentially more effective conjugates, which together harness the necessary potency, specificity, and biodistribution parameters required for improved therapeutic outcomes.

  5. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus... SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4100 Radiofrequency electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  6. 21 CFR 886.4300 - Intraocular lens guide.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to direct... lenses, the device is exempt from the premarket notification procedures in subpart E of part 807 of this...

  7. 21 CFR 886.4275 - Intraocular fluid.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4275 Intraocular fluid. (a) Identification. An intraocular fluid is a device consisting of a nongaseous fluid intended to be introduced into the eye to aid... section 515 of the act is required before this device may be commercially distributed. See § 886.3. ...

  8. 21 CFR 886.1500 - Headband mirror.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1500 Headband mirror. (a) Identification. A headband mirror is a device intended to be strapped to the head of the user to reflect light for use in examination of the eye. (b) Classification. Class I (general controls). The device is exempt from the...

  9. 21 CFR 886.1380 - Diagnostic condensing lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic condensing lens. 886.1380 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1380 Diagnostic condensing lens. (a) Identification. A diagnostic condensing lens is a device used in binocular indirect ophthalmoscopy (a procedure...

  10. 21 CFR 886.1350 - Keratoscope.

    Science.gov (United States)

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1350 Keratoscope. (a) Identification. A keratoscope is an AC-powered or battery-powered device intended to measure and evaluate the corneal curvature of the eye. Lines...

  11. [Cysteamine ophthalmic hydrogel for the treatment of ocular cystinosis].

    Science.gov (United States)

    Fernández-Ferreiro, Anxo; Luaces-Rodríguez, Andrea; Díaz-Tomé, Victoria; Gil-Martínez, María; Rodríguez Ares, María Teresa; Touriño Peralba, Rosario; Blanco-Méndez, José; González-Barcia, Miguel; Otero-Espinar, Francisco Javier; Lamas, María Jesús

    2017-11-01

    Ocular cystinosis is a rare disease characterised by the deposit of cystine crystals on the corneal surface, which hinder patients' eyesight. Oral cysteamine is given as cysteamine; however, it does not reach the cornea due to the lack of corneal vascularization making necessary its  administration by the topical ocular route. The aim of the present study is to  determine the stability of an ophthalmic hydrogel of cysteamine, which can be  potentially prepared at hospital pharmacy departments, under different preservation conditions during a follow-up of 30 days. Different physical  and chemical parameters were evaluated: osmolality, pH and  cysteamine concentration, which has been measured by a method of ultra  performance liquid chromatography-tandem mass spectrometer (UPLC-MS/MS).  Descriptive assays were also performed, such as transparency measurement and  microbiological assays in order to verify its sterility. The obtained results  allow us to conclude that the cysteamine hydrogel is stable during 30 days,  being recommendable its preservation in refrigerated conditions. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  12. Patterns of ophthalmic emergencies presenting to a referral hospital in Medina City, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Omar M. Alabbasi

    2017-10-01

    Full Text Available Background: Data are required on ophthalmic cases that present to the emergency eye clinics in Madinah, Saudi Arabia for proper allocation of healthcare resources. Objectives: To determine the frequency and various diagnoses of patients presenting to the A&E at Ohud Hospital, Madinah, Saudi Arabia. Methods: Data was collected prospectively for all patients who presented to the A&E ophthalmology clinic from June 2014 to September 2014. The data was analyzed and presented using frequency of incidence and percentages. Chi-square tests were used to evaluate the diagnoses based on age, sex and nationality. P ≤ 0.05 indicated statistical significance. Results: The study sample included 868 patients. The male-to-female ratio was 1.1:1.0. The main age categories included patients ≥45 years of age (256 patients and 251 patients between the ages of 15–30 years. Various types of Conjunctivitis was the most common diagnosis, reported in 282 patients (32.5%, and followed by dry eye syndrome in 156 (18% patients. Nasolacrimal duct obstruction in 156 patients (18%. Eyelid infections were detected in 102 patients (12%, corneal abrasion in 102 patients (9.3%. Various eye traumas was diagnosed in 30 patients (3.5%, increased intraocular pressure (IOP in 17 patients (2%, ruptured globe in 2 patients (0.2% and various other non-emergency pathologies in the remaining eyes. There were no significant differences in patient’s characteristics and categories of diagnoses. Conclusion: Non-emergent ophthalmic cases were the most common reason for the ophthalmology emergency room visits. It was observed that most cases could be referred to outpatient departments and potentially be managed by primary healthcare providers. This would be more cost effective and will also allow for better management of vision threatening ocular emergencies.

  13. A fluid-structure interaction model of the internal carotid and ophthalmic arteries for the noninvasive intracranial pressure measurement method.

    Science.gov (United States)

    Misiulis, Edgaras; Džiugys, Algis; Navakas, Robertas; Striūgas, Nerijus

    2017-05-01

    Accurate and clinically safe measurements of intracranial pressure (ICP) are crucial for secondary brain damage prevention. There are two methods of ICP measurement: invasive and noninvasive. Invasive methods are clinically unsafe; therefore, safer noninvasive methods are being developed. One of the noninvasive ICP measurement methods implements the balance principle, which assumes that if the velocity of blood flow in both ophthalmic artery segments - the intracranial (IOA) and extracranial (EOA) - is equal, then the acting ICP on the IOA and the external pressure (Pe) on the EOA are also equal. To investigate the assumption of the balance principle, a generalized computational model incorporating a fluid-structure interaction (FSI) module was created and used to simulate noninvasive ICP measurement by accounting for the time-dependent behavior of the elastic internal carotid (ICA) and ophthalmic (OA) arteries and their interaction with pulsatile blood flow. It was found that the extra balance pressure term, which incorporates the hydrodynamic pressure drop between measurement points, must be added into the balance equation, and the corrections on a difference between the velocity of blood flow in the IOA and EOA must be made, due to a difference in the blood flow rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. 21 CFR 886.4270 - Intraocular gas.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4270 Intraocular gas. (a) Identification. An intraocular gas is a device consisting of a gaseous fluid intended to be introduced into the eye to place pressure... required. As of May 28, 1976, an approval under section 515 of the act is required before this device may...

  15. 21 CFR 886.1690 - Pupillograph.

    Science.gov (United States)

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1690 Pupillograph. (a) Identification. A pupillograph is an AC-powered device intended to measure the pupil of the eye by reflected light and record the responses of the...

  16. WE-DE-201-05: Evaluation of a Windowless Extrapolation Chamber Design and Monte Carlo Based Corrections for the Calibration of Ophthalmic Applicators

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, J; Culberson, W; DeWerd, L [University of Wisconsin Medical Radiation Research Center, Madison, WI (United States); Soares, C [NIST (retired), Gaithersburg, MD (United States)

    2016-06-15

    Purpose: To test the validity of a windowless extrapolation chamber used to measure surface dose rate from planar ophthalmic applicators and to compare different Monte Carlo based codes for deriving correction factors. Methods: Dose rate measurements were performed using a windowless, planar extrapolation chamber with a {sup 90}Sr/{sup 90}Y Tracerlab RA-1 ophthalmic applicator previously calibrated at the National Institute of Standards and Technology (NIST). Capacitance measurements were performed to estimate the initial air gap width between the source face and collecting electrode. Current was measured as a function of air gap, and Bragg-Gray cavity theory was used to calculate the absorbed dose rate to water. To determine correction factors for backscatter, divergence, and attenuation from the Mylar entrance window found in the NIST extrapolation chamber, both EGSnrc Monte Carlo user code and Monte Carlo N-Particle Transport Code (MCNP) were utilized. Simulation results were compared with experimental current readings from the windowless extrapolation chamber as a function of air gap. Additionally, measured dose rate values were compared with the expected result from the NIST source calibration to test the validity of the windowless chamber design. Results: Better agreement was seen between EGSnrc simulated dose results and experimental current readings at very small air gaps (<100 µm) for the windowless extrapolation chamber, while MCNP results demonstrated divergence at these small gap widths. Three separate dose rate measurements were performed with the RA-1 applicator. The average observed difference from the expected result based on the NIST calibration was −1.88% with a statistical standard deviation of 0.39% (k=1). Conclusion: EGSnrc user code will be used during future work to derive correction factors for extrapolation chamber measurements. Additionally, experiment results suggest that an entrance window is not needed in order for an extrapolation

  17. Ocular findings and reference values for selected ophthalmic diagnostic tests in the macaroni penguin (Eudyptes chrysolophus) and southern rockhopper penguin (Eudyptes chrysocome).

    Science.gov (United States)

    Bliss, Cassandra D; Aquino, Susette; Woodhouse, Sarah

    2015-01-01

    To describe ophthalmic examination findings and standard diagnostic test results in 2 penguin species. Macaroni & Southern Rockhopper Penguins. Complete ophthalmic examinations including Schirmer tear test (STT), modified phenol red thread test (PTT), tonometry, and echobiometry were performed on penguins housed at the Detroit Zoo. Mean and standard deviation of ophthalmic tests are reported and compared for significance using two sample t-tests with significance set at P Penguins, and 68% of Rockhopper Penguins. There were anterior segment anomalies in all eyes with cataracts consistent with lens-induced uveitis. The mean modified PTT for the Macaronis was 24.7 ± 6.37 mm/15 s and 25.1 ± 7.07 mm/15 s in the Rockhoppers. The mean STT value for the Macaronis was 12.1 ± 5.43 mm/min and 11.0 ± 3.96 mm/min in the Rockhoppers. Mean intraocular pressure (IOP) for the Macaronis was 21.9 ± 7.05 mmHg measured by applanation tonometry and 29.1 ± 7.16 mmHg using rebound tonometry. The Rockhoppers had a mean IOP of 20.0 ± 5.77 mmHg and 24.1 ± 5.09 mmHg for applanation and rebound tonometry, respectively. In both populations, there was a significant difference in IOP measurement between the two instruments. In the Macaroni penguins, the presence of cataracts correlated significantly with increased age and lower IOP readings. Anterior chamber distance and axial globe length were significantly greater in males than in females in both penguin species. © 2013 American College of Veterinary Ophthalmologists.

  18. 21 CFR 886.1880 - Fusion and stereoscopic target.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fusion and stereoscopic target. 886.1880 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1880 Fusion and stereoscopic target. (a) Identification. A fusion and stereoscopic target is a device intended for use as a viewing object...

  19. 21 CFR 886.1390 - Flexible diagnostic Fresnel lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flexible diagnostic Fresnel lens. 886.1390 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1390 Flexible diagnostic Fresnel lens. (a) Identification. A flexible diagnostic Fresnel lens is a device that is a very thin lens which has...

  20. 21 CFR 886.1510 - Eye movement monitor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Eye movement monitor. 886.1510 Section 886.1510...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1510 Eye movement monitor. (a) Identification. An eye movement monitor is an AC-powered device with an electrode intended to measure and record...

  1. 21 CFR 886.4445 - Permanent magnet.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Permanent magnet. 886.4445 Section 886.4445 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4445 Permanent magnet. (a) Identification. A permanent magnet is a nonelectric device that generates a magnetic field intended to find and remove metallic...

  2. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to replace the natural lens of an eye. (b) Classification. Class III. (c) Date PMA or notice of completion of a...

  3. 21 CFR 886.4070 - Powered corneal burr.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4070 Powered corneal burr. (a) Identification. A powered corneal burr is an AC-powered or battery-powered device that is a motor and drilling tool intended to remove rust rings from the cornea of the eye. (b) Classification. Class I (general controls). When...

  4. A method for the calibration of concave 90Sr+90Y ophthalmic applicators

    International Nuclear Information System (INIS)

    Soares, C.G.

    1992-01-01

    At the Amersham Laboratory (Amersham, UK) absorbed-dose rate in tissue at a depth of 7 mg cm -2 from curved ophthalmic applicators is measured with calibrated scintillator probes (Amersham International 1979, Sinclair and Trott 1956). The probes are approximately 3 mm in diameter, 0.5 mm thick and are covered with 7 mg cm -2 of aluminium. They are calibrated using standard sources whose dose rate has been determined using an extrapolation chamber equipped with a 3 mm diameter collecting electrode. Crucial to this technique is the availability of well calibrated sources of nearly the same geometry and dose rate as the source to be calibrated. A technique is presented here which yields accurate measurement of the surface absorbed-dose rate in a very simple and straightforward fashion. (author)

  5. A curious fact: Photic sneeze reflex. Autosomical dominant compelling helio-ophthalmic outburst syndrome.

    Science.gov (United States)

    Sevillano, C; Parafita-Fernández, A; Rodriguez-Lopez, V; Sampil, M; Moraña, N; Viso, E; Cores, F J

    2016-07-01

    To assess ocular involvement in the pathophysiology of autosomal dominant compelling helio-ophthalmic outburst syndrome (ACHOOs). An interview was conducted with a Caucasian family that showed clinical features of ACHOOs. Twelve of them had photic reflex and were recruited. A complete eye evaluation was made. A dominant autosomal inheritance with mild penetrance was demonstrated, with 67% of the studied subjects showing some degree of prominent corneal nerves. No other eye changes were found. Prominent corneal nerves may be associated with ACHOOs. The other eye structures studied do not seem to play a role in ACHOOs. Further studies are needed to understand the physiology of the ACHOOs. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  6. Profiling extractable and leachable inorganic impurities in ophthalmic drug containers by ICP-MS.

    Science.gov (United States)

    Solomon, Paige; Nelson, Jenny

    2018-03-01

    In this study, we investigated the elemental impurities present in the plastic material of ophthalmic eye drop bottles using inductively coupled plasma-mass spectrometry (ICP-MS). Metallic contaminations, especially localized within the small cavity of the eye, can significantly perturb the ocular metallome. The concern is two-fold: first certain elements, for example heavy metals, can be toxic to humans at even trace levels, and second, these contaminations can have adverse reactions with other medicines or enzymatic processes in the eye. The implication of redox-active metals in cataract formation is one such biological consequence. The analysis demonstrated the effect of aggressive storage and transportation conditions on elemental extractable and leachable contamination, and posits that release of these elemental impurities can disrupt metallome equilibrium in the ocular compartment, leading to toxicity and disease.

  7. Effects of Diquafosol Ophthalmic Solution on Quality of Life in Dry Eye Assessed Using the Dry Eye-Related Quality-of-Life Score Questionnaire: Effectiveness in Patients While Reading and Using Visual Display Terminals.

    Science.gov (United States)

    Utsunomiya, Tsugiaki; Kawahara, Atsushi; Hanada, Kazuomi; Yoshida, Akitoshi

    2017-08-01

    Diquafosol ophthalmic solution improves objective findings in the ocular surface and subjective symptoms in patients with dry eye. The Dry Eye-Related Quality-of-Life Score (DEQS) questionnaire was developed to assess dry eye symptoms and their effects on quality of life. However, because little research using the DEQS has been reported, we evaluated the effects of diquafosol ophthalmic solution on ocular surface findings and quality of life using the DEQS in patients with dry eye. Sixty-three patients with dry eye were assigned to the control group (artificial tears) or diquafosol group. Both groups instilled 1 drop of the solution in both eyes 6 times daily and were evaluated after 2 weeks; the diquafosol group also was instructed to be examined at 1 and 3 months. We evaluated the subjective symptoms using the DEQS, fluorescein staining score, tear film breakup time (BUT), Schirmer testing, and lower tear meniscus height with anterior-segment optical coherence tomography. In the diquafosol group, the fluorescein staining score, BUT, tear meniscus height, and DEQS scores improved significantly compared with before treatment in contrast to the control group. Furthermore, in the diquafosol group, the staining score and BUT improved significantly compared with the control group. Analysis of each DEQS item indicated that diquafosol ophthalmic solution relieved foreign body sensation and problems when reading and using visual display terminals compared with the control group. Diquafosol ophthalmic solution was effective in patients with dry eye, especially those with foreign body sensation and problems when reading and using visual display terminals.

  8. The Product Quality Research Institute (PQRI) Leachables and Extractables Working Group Initiatives for Parenteral and Ophthalmic Drug Product (PODP).

    Science.gov (United States)

    Paskiet, Diane; Jenke, Dennis; Ball, Douglas; Houston, Christopher; Norwood, Daniel L; Markovic, Ingrid

    2013-01-01

    The Product Quality Research Institute (PQRI) is a non-profit consortium of organizations working together to generate and share timely, relevant, and impactful information that advances drug product quality and development. The collaborative activities of PQRI participants have, in the case of orally inhaled and nasal drug products (OINDPs), resulted in comprehensive and widely-accepted recommendations for leachables assessments to help ensure patient safety with respect to this class of packaged drug products. These recommendations, which include scientifically justified safety thresholds for leachables, represent a significant milestone towards establishing standardized approaches for safety qualification of leachables in OINDP. To build on the success of the OINDP effort, PQRI's Parenteral and Ophthalmic Drug Products (PODP) Leachables and Extractables Working Group was formed to extrapolate the OINDP threshold concepts and best practice recommendations to other dosage forms with high concern for interaction with packaging/delivery systems. This article considers the general aspects of leachables and their safety assessment, introduces the PODP Work Plan and initial study Protocol, discusses the laboratory studies being conducted by the PODP Chemistry Team, outlines the strategy being developed by the PODP Toxicology Team for the safety qualification of PODP leachables, and considers the issues associated with application of the safety thresholds, particularly with respect to large-volume parenterals. Lastly, the unique leachables issues associated with biologics are described. The Product Quality Research Institute (PQRI) is a non-profit consortium involving industry organizations, academia, and regulatory agencies that together provide recommendations in support of regulatory guidance to advance drug product quality. The collaborative activities of the PQRI Orally Inhaled and Nasal Drug Products Leachables and Extractables Working Group resulted in a

  9. Ophthalmic Manifestations of Xeroderma Pigmentosum: A Perspective from the United Kingdom.

    Science.gov (United States)

    Lim, Rongxuan; Sethi, Mieran; Morley, Ana M S

    2017-11-01

    To document the ocular manifestations of xeroderma pigmentosum (XP), presenting via the United Kingdom (UK) XP service, and to analyze the correlations between XP genotype and ophthalmic phenotype. Prospective observational case series. Eighty-nine patients seen by the UK Nationally Commissioned XP Service, from April 2010 to December 2014, with a genetically confirmed diagnosis of XP. Patients underwent a full ophthalmic examination at each visit. Clinical features from both eyes were recorded on a standard proforma. The most recent assessments were analyzed. A 2-tailed Fisher exact test was used to assess for differences in ocular features between patients in XP subgroups with impaired transcription coupled nucleotide excision repair (TC-NER) (category 1: XP-A, B, D, F, and G) and preserved TC-NER (category 2: XP-C, E, and V). Lid and periocular abnormalities, ocular surface pathologies, neuro-ophthalmologic abnormalities, lens and retinal abnormalities, and visual acuity (VA). Ninety-three percent of XP patients in our cohort had ocular involvement, with 65% describing photophobia. The most common abnormalities were in the periocular skin and ocular surface, including interpalpebral conjunctival melanosis (44%) and conjunctival injection (43%). Eleven percent of patients had required treatment for periocular cancers and 2% for ocular surface cancers. The most common neuro-ophthalmologic finding was minimal pupillary reaction to light (25%). Patients in category 2 had significantly more ocular surface abnormalities than patients in category 1, including a greater proportion of conjunctival injection (P = 0.003), conjunctival corkscrew vessels (P < 0.001), corneal scarring (P = 0.01) and pingueculae under the age of 50 (P = 0.02). Meanwhile, patients in category 1 had a higher proportion of poorly reactive pupils (P < 0.001) and abnormal ocular movements (P = 0.03) compared with those in category 2. Five patients (6%) presented to ophthalmologists with ocular

  10. Effect of topical ophthalmic epinastine and olopatadine on tear volume in mice.

    Science.gov (United States)

    Villareal, Arturo L; Farley, William; Pflugfelder, Stephen C

    2006-12-01

    To investigate the effects of topical epinastine and olopatadine on tear volume by using a mouse model. Eighty-five C57BL6 mice (170 eyes) were treated twice daily with topical ophthalmic epinastine 0.05%, olopatadine 0.1%, or atropine 1% or served as untreated controls. A thread-wetting assay was used to measure tear volume at baseline and 15, 45, 90, 120, and 240 minutes after the last instillation of the drug on days 2 and 4 of treatment. After 2 days of treatment, epinastine-treated mice showed greater mean tear volumes than olopatadine-treated mice did at 15, 45, 90, and 240 minutes, with statistical significance at 15 and 45 minutes (Placrimal functional unit, epinastine may be an especially good choice for the treatment of allergic conjunctivitis in patients with dry eye disease or in those who are at risk for developing dry eye.

  11. N-Butyl Cyanoacrylate Proved Beneficial to Avoid a Nontarget Embolization of the Ophthalmic Artery in Endovascular Management of Epistaxis

    Science.gov (United States)

    Shuster, A.; Gunnarsson, T.; Klurfan, P.; Larrazabal, R.

    2011-01-01

    Summary Epistaxis is a common disorder affecting equally both genders. Posterior origin of epistaxis in some instances requires endovascular treatment. Anastomoses between external carotid artery and internal carotid or ophthalmic arteries heighten the risk of stroke or blindness, if particles of polyvinyl alcohol are used for embolization. We report a case of 90-year-old man for whom successful embolization with N-Butyl Cyanoacrylate glue was performed as an alternative treatment for recurrent epistaxis. PMID:21561554

  12. Degree of corneal anaesthesia after topical application of 0.4% oxybuprocaine hydrochloride and 0.5% proparacaine hydrochloride ophthalmic solution in clinically normal cattle.

    Science.gov (United States)

    Little, W B; Jean, G St; Sithole, F; Little, E; Jean, K Yvorchuk-St

    2016-06-01

    The use of corneal anaesthesia is necessary for a range of clinical purposes. Therefore, we assessed and compared the efficacy of corneal anaesthesia after application of 0.4% oxybuprocaine hydrochloride and 0.5% proparacaine hydrochloride ophthalmic solution in clinically normal cattle. The 24 clinically normal cows were allocated into two groups. Cows in group 1 (n = 12) received 0.2 mL of 0.4% oxybuprocaine hydrochloride with fluorescein ophthalmic solution in one eye and 0.2 mL of sterile saline (0.9% NaCl) with fluorescein in the contralateral eye (control). Group 2 (n = 12) received 0.2 mL of 0.4% oxybuprocaine hydrochloride with fluorescein ophthalmic solution in one eye and 0.2 mL of 0.5% proparacaine hydrochloride with fluorescein in the contralateral eye (control). In each group, corneal touch threshold was determined by Cochet-Bonnet aesthesiometer for both eyes immediately prior to topical administration of solutions, at 1 min and 5 min after administration of topical solutions and every 5 min thereafter for a total of 75 min. Significant corneal anaesthesia was noted immediately following topical application of both oxybuprocaine and proparacaine as compared with controls, with maximal corneal anaesthesia noted 1 min after administration. Both oxybuprocaine and proparacaine produced significant corneal anaesthesia for the duration of the 75-min study. Neither oxybuprocaine hydrochloride nor proparacaine hydrochloride treatment resulted in visible adverse effects. There are limited data available demonstrating the efficacy and duration of corneal anaesthetic agents in cattle. Both oxybuprocaine hydrochloride and proparacaine hydrochloride should be considered practical options for providing corneal anaesthesia in cattle in a clinical setting. © 2016 Australian Veterinary Association.

  13. 21 CFR 886.1400 - Maddox lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Maddox lens. 886.1400 Section 886.1400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1400 Maddox lens. (a) Identification. A Maddox lens is a device...

  14. 21 CFR 886.5844 - Prescription spectacle lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prescription spectacle lens. 886.5844 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5844 Prescription spectacle lens. (a) Identification. A prescription spectacle lens is a glass or plastic device that is a lens intended to be worn by...

  15. 21 CFR 886.4440 - AC-powered magnet.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and remove...

  16. 21 CFR 886.5842 - Spectacle frame.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Spectacle frame. 886.5842 Section 886.5842 Food... DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5842 Spectacle frame. (a) Identification. A spectacle frame is a device made of metal or plastic intended to hold prescription spectacle lenses worn by a...

  17. 21 CFR 886.5915 - Optical vision aid.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Optical vision aid. 886.5915 Section 886.5915 Food... DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5915 Optical vision aid. (a) Identification. An optical vision aid is a device that consists of a magnifying lens with an accompanying AC-powered or...

  18. 21 CFR 886.5540 - Low-vision magnifier.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low-vision magnifier. 886.5540 Section 886.5540...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5540 Low-vision magnifier. (a) Identification. A low-vision magnifier is a device that consists of a magnifying lens intended for use by a patient...

  19. 21 CFR 886.5870 - Low-vision telescope.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low-vision telescope. 886.5870 Section 886.5870...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5870 Low-vision telescope. (a) Identification. A low-vision telescope is a device that consists of an arrangement of lenses or mirrors intended for...

  20. Pituitary Dysfunction from an Unruptured Ophthalmic Internal Carotid Artery Aneurysm with Improved 2-year Follow-up Results: A Case Report.

    Science.gov (United States)

    Qi, Meng; Ye, Ming; Li, Meng; Zhang, Peng

    2018-01-01

    Internal carotid artery (ICA) supraclinoid segment aneurysms extending into the sellar region and leading to pituitary dysfunction are a rare occurrence. To date, long-term follow up of pituitary function 2 years post-treatment has never been reported. Herein, we present a case of pituitary dysfunction due to an unruptured ophthalmic segment internal carotid artery aneurysm and report improved 2-year follow-up results. A 76-year-old male presented with disturbed consciousness due to hyponatremia, which was caused by hypoadrenocorticism resulting from pituitary dysfunction complicated by hypogonadism and hypothyroidism. Computed tomography angiography revealed an intracranial aneurysm of the ophthalmic segment of the right ICA with an intrasellar extension. Thus, digital subtraction angiography and coil embolization were performed, followed by hormone replacement therapy. A 2-year follow-up revealed a partial improvement in the pituitary function, including complete restoration of thyroid-stimulating hormone level and other thyroid hormones levels, and partial restoration of testosterone levels, followed by discontinuation of thyroid hormone replacement therapy. However, the mechanisms of such pituitary dysfunction and the effects of various treatments, including clipping and coiling, on different hormones of pituitary function recovery remain unclear. A long-term follow-up of >2 years may elucidate the pituitary function recovery post-treatment and provide a medication adjustment for hormone replacement therapy.

  1. Validation of a stability-indicating spectrometric method for the determination of sulfacetamide sodium in pure form and ophthalmic preparations

    Directory of Open Access Journals (Sweden)

    Sofia Ahmed

    2017-01-01

    Full Text Available Introduction: Sulfacetamide sodium is a widely used sulfonamide for ophthalmic infections. Objective: A number of analytical methods have been reported for the analysis of sulfacetamide but they lack the ability to determine both the active drug and its major degradation product, sulfanilamide, simultaneously in a sample. Materials and Methods: In the present study a simple, rapid and economical stability-indicating UV spectrometric method has been validated for the simultaneous assay of sulfacetamide sodium and sulfanilamide in pure form and in ophthalmic preparations. Results: The method has been found to be accurate (recovery 100.03 ±0.589% and precise (RSD 0.587% with detectable and quantifiable limits of 1.67×10–6 M (0.04 mg% and 5.07×10–6 M (0.13 mg%, respectively for the assay of pure sulfacetamide sodium. The method is also found to be accurate and precise to small changes in wavelength, pH and buffer concentration as well as to forced degradation. The study further includes the validation of the method for the assay of pure sulfanilamide in solution, which has been found to be accurate, precise and robust. Conclusion: The results indicate that the proposed two-component spectrometric method is stability-indicating and can be used for the simultaneous assay of both sulfacetamide sodium and sulfanilamide in synthetic mixtures and degraded solutions.

  2. A New Generation Fiber Optic Probe: Characterization of Biological Fluids, Protein Crystals and Ophthalmic Diseases

    Science.gov (United States)

    Ansari, Rafat R.; Suh, Kwang I.

    1996-01-01

    A new fiber optic probe developed for determining transport properties of sub-micron particles in fluids experiments in a microgravity environment has been applied to characterize particulate dispersions/suspensions in various challenging environments which have been hitherto impossible. The probe positioned in front of a sample delivers a low power light (few nW - 3mW) from a laser and guides the light which is back scattered by the suspended particles through a receiving optical fiber to a photo detector and to a digital correlator. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions. It has been applied to characterize various biological fluids, protein crystals, and ophthalmic diseases.

  3. Automatic segmentation of closed-contour features in ophthalmic images using graph theory and dynamic programming

    Science.gov (United States)

    Chiu, Stephanie J.; Toth, Cynthia A.; Bowes Rickman, Catherine; Izatt, Joseph A.; Farsiu, Sina

    2012-01-01

    This paper presents a generalized framework for segmenting closed-contour anatomical and pathological features using graph theory and dynamic programming (GTDP). More specifically, the GTDP method previously developed for quantifying retinal and corneal layer thicknesses is extended to segment objects such as cells and cysts. The presented technique relies on a transform that maps closed-contour features in the Cartesian domain into lines in the quasi-polar domain. The features of interest are then segmented as layers via GTDP. Application of this method to segment closed-contour features in several ophthalmic image types is shown. Quantitative validation experiments for retinal pigmented epithelium cell segmentation in confocal fluorescence microscopy images attests to the accuracy of the presented technique. PMID:22567602

  4. 21 CFR 886.1395 - Diagnostic Hruby fundus lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic Hruby fundus lens. 886.1395 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1395 Diagnostic Hruby fundus lens. (a) Identification. A diagnostic Hruby fundus lens is a device that is a 55 diopter lens intended for use in the...

  5. Survey of ophthalmic anterior segment findings and intraocular pressure in 95 North American box turtles (Terrapene spp.).

    Science.gov (United States)

    Espinheira Gomes, Filipe; Brandão, João; Sumner, Julia; Kearney, Michael; Freitas, Inês; Johnson, James; Cutler, Daniel; Nevarez, Javier

    2016-03-01

    To describe the ophthalmic biomicroscopy findings and intraocular pressures (IOP) in a captive population of box turtles and to determine whether a relationship exists between body morphometrics or health status and IOP. Hundred and three box turtles (69 Gulf coast, 24 three-toed, one ornate, one eastern, and eight unidentified) were triaged into three different color-coded groups: green (healthy), yellow (abnormal physical examination with no need for immediate care), and red (immediate care required). Both eyes were evaluated by rebound tonometry and slit-lamp biomicroscopy. Body weight and morphometric data were recorded. Intraocular pressures measurements were available for 190 eyes, slit-lamp biomicroscopy was available for 170 eyes, and morphometric data were available for 81 turtles. IOP in Gulf coast turtles (138 eyes) was 6.7 ± 1.4 mmHg OU. IOP in three-toed turtles (48 eyes) was 8.3 ± 1.5 mmHg OU, which was significantly higher than in Gulf coast turtles (P turtles only. There was a mild negative correlation between morphometrics and IOP in Gulf coast and three-toed turtles. Fifteen of 87 turtles had unilateral corneal or lenticular opacities; 3/87 had bilateral corneal or lenticular disease; and 3/87 had adnexal abnormalities. Different subspecies of box turtles have different normal intraocular pressures as measured by rebound tonometry, which was influenced by the animals' health status in one subspecies. Some morphometric parameters were found to be associated with IOP. Box turtles are often affected with ophthalmic abnormalities of unknown clinical significance. © 2015 American College of Veterinary Ophthalmologists.

  6. 21 CFR 886.1360 - Visual field laser instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Visual field laser instrument. 886.1360 Section 886.1360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument...

  7. 21 CFR 886.1150 - Visual acuity chart.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Visual acuity chart. 886.1150 Section 886.1150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1150 Visual acuity chart. (a) Identification...

  8. Preoperative Hand Decontamination in Ophthalmic Surgery: A Comparison of the Removal of Bacteria from Surgeons' Hands by Routine Antimicrobial Scrub versus an Alcoholic Hand Rub.

    Science.gov (United States)

    Forer, Yaara; Block, Colin; Frenkel, Shahar

    2017-09-01

    The goal of this experiment was to evaluate and compare the antimicrobial efficacy of routine preoperative hand washing using commercial medicated sponge brushes versus an alcoholic hand rub, by comparing bacterial growth on ophthalmic surgeons' hands after application of each of these methods. Twenty ophthalmic surgeons were recruited at the Hadassah-Hebrew University Medical Center in Jerusalem, Israel. Samples were collected twice from the hands of each surgeon after hand decontamination using two different protocols during routine surgical practice. The routine preparation consisted of a 3-minute surgical scrub using commercial brush-sponges incorporating either 4% chlorhexidine gluconate (CHG) or 1% povidone-iodine (PVP-I) formulations with detergent, followed by drying the hands with a sterile towel, while the 70% ethanol solution was applied for 60-seconds and allowed to air dry. Half of the group was randomly assigned to provide samples first after the routine method and the alcoholic solution a week later, and the other half of the group was sampled in the reverse order. Viable counts of bacteria were evaluated using a modified glove juice method. Bacterial colonies were enumerated after incubation for 24 hours and expressed as colony forming units (CFU)/mL for each pair of hands. Geometric mean counts were 1310 and 39 CFU/mL, in the routine and alcohol rub groups, respectively, representing a mean log 10 reduction in 1.53. The difference between the paired bacterial counts for the routine versus the alcohol rub was statistically significant (p surgical hand preparation with PVP-I and CHG in a population of practicing ophthalmic surgeons in the operative clinical setting. Thus, it provides a safe alternative as a preoperative hand disinfection method.

  9. SIMULTANEOUS ESTIMATION OF MOXIFLOXACIN HYDROCHLORIDE AND DEXAMETHASONE SODIUM PHOSPHATE IN BULK AND IN OPHTHALMIC SOLUTION BY RP- HPLC

    OpenAIRE

    DHUMAL, D. M; SHIRKHEDKAR, A. A; NERKAR, P. P; SURANA, S. J

    2012-01-01

    A new simple, precise, accurate and selective RP-HPLC method has been developed and validated for simultaneous estimation of Moxifloxacin Hydrochloride (MOX) and Dexamethasone Sodium Phosphate (DSP) in Ophthalmic Solution. The method was carried out on a Qualisil RP C-8 (250 mm x 4.6 mm, 5 µm) column with a mobile phase consisting of Methanol: Water (75:25 v/v) pH adjusted to 3.0 with ortho-phosphoric acid of aqueous phase and flow rate of 1.0 mL min¹. Detection was carried out at 240 nm. The...

  10. Preserved and unpreserved 12 anti-allergic ophthalmic solutions and ocular surface toxicity: in vitro assessment in four cultured corneal and conjunctival epithelial cell lines.

    Science.gov (United States)

    Ayaki, Masahiko; Iwasawa, Atsuo; Yaguchi, Shigeo; Koide, Ryohei

    2010-12-01

    In the present study, we evaluated the cytotoxicity of anti-allergic ophthalmic solutions in cultured corneal and conjunctival cells, namely SIRC (rabbit corneal epithelium), BCE C/D-1b (bovine corneal epithelial cells), RC-1 (rabbit corneal epithelium), and Chang (human conjunctival cells). The viability of cell cultures was determined following the exposure of cells to 12 commercially available anti-allergic ophthalmic solutions for varying exposure times and at various dilutions using the MTT and neutral red assays. The cell viability score (CVS) was used to compare the toxicity of different drugs. Based on CVS data, the order of cell viability after exposure to the drugs was Zepelin ≥ Tramelas PF ≥ Cumorol PF ≥ Ketotifen PF ≥ Eyevinal = Fumarton ≥ Cumorol > Intal ≥ Rizaben ≥ Tramelas ≥ Patanol Livostin. In conclusion, cell viability was mostly affected by the concentration of benzalkonium chloride rather than the active component and/or the anti-allergic action of the drug. The CVS was useful in comparing the toxicity of different drugs.

  11. Traditional eye medicine use by newly presenting ophthalmic patients to a teaching hospital in south-eastern Nigeria: socio-demographic and clinical correlates

    Directory of Open Access Journals (Sweden)

    Uche Judith

    2009-10-01

    Full Text Available Abstract Background This study set out to determine the incidence, socio-demographic, and clinical correlates of Traditional Eye Medicine (TEM use in a population of newly presenting ophthalmic outpatients attending a tertiary eye care centre in south-eastern Nigeria. Methods In a comparative cross-sectional survey at the eye clinic of the University of Nigeria Teaching Hospital (UNTH, Enugu, between August 2004 - July 2006, all newly presenting ophthalmic outpatients were recruited. Participants' socio-demographic and clinical data and profile of TEM use were obtained from history and examination of each participant and entered into a pretested questionnaire and proforma. Participants were subsequently categorized into TEM- users and non-users; intra-group analysis yielded proportions, frequencies, and percentages while chi-square test was used for inter-group comparisons at P = 0.01, df = 1. Results Of the 2,542 (males, 48.1%; females, 51.9% participants, 149 (5.9% (males, 45%; females, 55% used TEM for their current eye disease. The TEMs used were chemical substances (57.7%, plant products (37.7%, and animal products (4.7%. They were more often prescribed by non-traditional (66.4% than traditional (36.9% medicine practitioners. TEMs were used on account of vision loss (58.5%, ocular itching (25.4% and eye discharge (3.8%. Reported efficacy from previous users (67.1% and belief in potency (28.2% were the main reasons for using TEM. Civil servants (20.1%, farmers (17.7%, and traders (14.1% were the leading users of TEM. TEM use was significantly associated with younger age (p Conclusion The incidence of TEM use among new ophthalmic outpatients at UNTH is low. The reasons for TEM use are amenable to positive change through enhanced delivery of promotive, preventive, and curative public eye care services. This has implications for eye care planners and implementers. To reverse the trend, we suggest strengthening of eye care programmes, even

  12. The eye of the Barbary sheep or aoudad (Ammotragus lervia: Reference values for selected ophthalmic diagnostic tests, morphologic and biometric observations

    Directory of Open Access Journals (Sweden)

    G.A. Fornazari

    2016-06-01

    Full Text Available The purpose of this study was to describe the normal ocular anatomy and establish reference values for ophthalmic tests in the Barbary sheep or aoudad (Ammotragus lervia. Aoudad eyes are large and laterally positioned in the head with several specialized anatomic features attributed to evolutionary adaptations for grazing. Normal values for commonly used ophthalmic tests were established, Schirmer tear test (STT - 27.22 ± 3.6 mm/min; Predominant ocular surface bacterial microbiota - Staphylococcus sp.; Corneal esthesiometry- 1.3 ± 0.4 cm; Intraocular pressure by rebound tonometry- 19.47 ± 3.9 mmHg; Corneal thickness- 630.07 ± 20.67 μm, B-mode ultrasonography of the globe- axial eye globe length 29.94 ± 0.96 mm, anterior chamber depth 5.03 ± 0.17 mm, lens thickness 9.4 ± 0.33 mm, vitreous chamber depth 14.1 ± 0.53 mm; Corneal diameter- horizontal corneal diameter 25.05 ± 2.18 mm, vertical corneal diameter 17.95 ± 1.68 mm; Horizontal palpebral fissure length- 34.8 ± 3.12 mm. Knowledge of these normal anatomic variations, biometric findings and normal parameters for ocular diagnostic tests may assist veterinary ophthalmologists in the diagnosis of ocular diseases in this and other similar species.

  13. 78 FR 5327 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-01-25

    ...). Executive Orders 12866 and 13563 direct Agencies to assess all costs and benefits of available regulatory... (including potential economic, environmental, public health and safety, and other advantages; distributive... with or without gold, silver, or titanium coating, manufacturers could begin marketing after they...

  14. 78 FR 9349 - Medical Devices; Ophthalmic Devices; Classification of the Eyelid Weight

    Science.gov (United States)

    2013-02-08

    ... value of the savings ranges from $28,746, at a 3-percent discount rate, to $20,470 at a 7-percent discount rate. C. Preliminary Regulatory Impact Analysis 1. Benefits Adopting the proposed rule would... value of the savings is $28,746, at a 3-percent discount rate, and $20,470, at a 7-percent discount rate...

  15. Pituitary dysfunction from an unruptured ophthalmic internal carotid artery aneurysm with improved 2-year follow-up results: A case report

    Directory of Open Access Journals (Sweden)

    Qi Meng

    2018-04-01

    Full Text Available Internal carotid artery (ICA supraclinoid segment aneurysms extending into the sellar region and leading to pituitary dysfunction are a rare occurrence. To date, long-term follow up of pituitary function 2 years post-treatment has never been reported. Herein, we present a case of pituitary dysfunction due to an unruptured ophthalmic segment internal carotid artery aneurysm and report improved 2-year follow-up results. A 76-year-old male presented with disturbed consciousness due to hyponatremia, which was caused by hypoadrenocorticism resulting from pituitary dysfunction complicated by hypogonadism and hypothyroidism. Computed tomography angiography revealed an intracranial aneurysm of the ophthalmic segment of the right ICA with an intrasellar extension. Thus, digital subtraction angiography and coil embolization were performed, followed by hormone replacement therapy. A 2-year follow-up revealed a partial improvement in the pituitary function, including complete restoration of thyroid-stimulating hormone level and other thyroid hormones levels, and partial restoration of testosterone levels, followed by discontinuation of thyroid hormone replacement therapy. However, the mechanisms of such pituitary dysfunction and the effects of various treatments, including clipping and coiling, on different hormones of pituitary function recovery remain unclear. A long-term follow-up of >2 years may elucidate the pituitary function recovery post-treatment and provide a medication adjustment for hormone replacement therapy.

  16. Evaluation of MEWDS-like lesions with fluorescein angiography and its frequency at an ophthalmic emergency department in Rio de Janeiro

    Directory of Open Access Journals (Sweden)

    Lillian Abreu Dias

    2015-08-01

    Full Text Available ABSTRACTPurpose:To characterize multiple evanescent white dot syndrome (MEWDS-like lesions as diagnosed by clinical exam and fluorescein angiography (FA to build an epidemiological profile of this disease and highlight the most common angiographical aspects. It is important to emphasize the existence of this syndrome and improve patients’ information about the natural good course of this disease.Methods:A cross-sectional study including all FA performed from July 2006 to October 2012 (6,111 exams analyzed in patients at our ophthalmic emergency department, with analysis of the different angiographic aspects of the MEWDS-diagnosed cases.Results:Among the 6,111 angiographies analyzed, 15 MEWDS cases were detected; the patients ranged in age from 13 to 42 years old, and the male/female ratio was 60% to 40% (nine male and six female. The most common FA aspects included hyperfluorescent dots, dots and spots in the retinal mid-periphery, and foveal granularity in 46% of the cases.Conclusions:MEWDS has a good prognosis, with spontaneous involution, which makes it difficult to diagnose because of the delayed access to ophthalmological assistance, in special FA examination, which highlights the lesions. This study was possible due to the quick access facility at a private ophthalmic emergency department and examination by an experienced ophthalmologist, along with complementary diagnosis by FA and better perception of the patients, thus ensuring good prognosis.

  17. Evaluation of MEWDS-like lesions with fluorescein angiography and its frequency at an ophthalmic emergency department in Rio de Janeiro.

    Science.gov (United States)

    Dias, Lillian Abreu; Morizot, Eduardo H

    2015-01-01

    To characterize multiple evanescent white dot syndrome (MEWDS)-like lesions as diagnosed by clinical exam and fluorescein angiography (FA) to build an epidemiological profile of this disease and highlight the most common angiographical aspects. It is important to emphasize the existence of this syndrome and improve patients' information about the natural good course of this disease. A cross-sectional study including all FA performed from July 2006 to October 2012 (6,111 exams analyzed) in patients at our ophthalmic emergency department, with analysis of the different angiographic aspects of the MEWDS-diagnosed cases. Among the 6,111 angiographies analyzed, 15 MEWDS cases were detected; the patients ranged in age from 13 to 42 years old, and the male/female ratio was 60% to 40% (nine male and six female). The most common FA aspects included hyperfluorescent dots, dots and spots in the retinal mid-periphery, and foveal granularity in 46% of the cases. MEWDS has a good prognosis, with spontaneous involution, which makes it difficult to diagnose because of the delayed access to ophthalmological assistance, in special FA examination, which highlights the lesions. This study was possible due to the quick access facility at a private ophthalmic emergency department and examination by an experienced ophthalmologist, along with complementary diagnosis by FA and better perception of the patients, thus ensuring good prognosis.

  18. Infraorbital nerve involvement on magnetic resonance imaging in European patients with IgG4-related ophthalmic disease: a specific sign.

    Science.gov (United States)

    Soussan, J Ben; Deschamps, R; Sadik, J C; Savatovsky, J; Deschamps, L; Puttermann, M; Zmuda, M; Heran, F; Galatoire, O; Picard, H; Lecler, A

    2017-04-01

    To measure the frequency of infraorbital nerve enlargement (IONE) on magnetic resonance imaging (MRI) in European patients suffering from an IgG4-related ophthalmic disease (IgG4-ROD) as compared to patients suffering from non-IgG4-related ophthalmic disease (non-IgG4-ROD). From January 2006 through April 2015, 132 patients were admitted for non-lymphoma, non-thyroid-related orbital inflammation. Thirty-eight had both pre-therapeutic orbital MRI and histopathological IgG4 immunostaining. Fifteen patients were classified as cases of IgG4-ROD and 23 patients as cases of non-IgG4-ROD. Two readers performed blinded analyses of MRI images. The main criterion was the presence of an IONE, defined as the infraorbital nerve diameter being greater than the optic nerve diameter in the coronal section. IONE was present in 53% (8/15) of IgG4-ROD cases whereas it was never present (0/23) in cases of non-IgG4-ROD (P IgG4-ROD. Recognition of this pattern may facilitate the accurate diagnosis for clinicians and allow for the adequate management and appropriate care of their patients. • IONE on an MRI is a specific sign of IgG4-ROD. • IONE recognition allows for a quicker diagnosis and appropriate management. • IONE appears when inflammation is in direct contact with the ION canal.

  19. Review of moxifloxacin hydrochloride ophthalmic solution in the treatment of bacterial eye infections

    Directory of Open Access Journals (Sweden)

    Darlene Miller

    2008-03-01

    Full Text Available Darlene MillerAbrams Ocular Microbiology Laboratory, Bascom Palmer Eye Institute, Anne Bates Leach Eye Hospital, Miller School of Medicine-University of Miami, FL, USAAbstract: Moxifloxacin hydrochloride ophthalmic solution 0.5% (Vigamox® is the ocular formulation/adaptation of moxifloxacin. Moxifloxacin is a broad spectrum 8-methoxyfluoroquinolone which terminates bacterial growth by binding to DNA gyrase (topoisomerase II and topoisomerase IV, essential bacterial enzymes involved in the replication, translation, repair and recombination of deoxyribonucleic acid. Affinity for both enzymes improves potency and reduces the probability of selecting resistant bacterial subpopulations. Vigamox is a bactericidal, concentration dependent, anti-infective. It is preservative free, and well tolerated with minimal ocular side effects. It provides increased penetration into ocular tissues and fluids with improved activity against Streptococci and Staphylococci species and moderate to excellent activity against clinically relevant, gram- negative ocular pathogens.Keywords: moxifloxacin, vigamox, pharmacodynamic indices, minimal inhibitory concentrations

  20. Colour Doppler analysis of ophthalmic vessels in the diagnosis of carotic artery and retinal vein occlusion, diabetic retinopathy and glaucoma: systematic review of test accuracy studies.

    Science.gov (United States)

    Bittner, Mario; Faes, Livia; Boehni, Sophie C; Bachmann, Lucas M; Schlingemann, Reinier O; Schmid, Martin K

    2016-12-07

    Colour Doppler analysis of ophthalmic vessels has been proposed as a promising tool in the diagnosis of various eye diseases, but the available diagnostic evidence has not yet been assessed systematically. We performed a comprehensive systematic review of the literature on the diagnostic properties of Colour Doppler imaging (CDI) assessing ophthalmic vessels and provide an inventory of the available evidence. Eligible papers were searched electronically in (Pre) Medline, Embase and Scopus, and via cross-checking of reference lists. The minimum requirement to be included was the availability of original data and the possibility to construct a two-by-two table. Study selection, critical appraisal using the QUADAS II instrument and extraction of salient study characteristics was made in duplicate. Sensitivity and specificity was computed for each study. We included 11 studies (15 two-by-two tables) of moderate methodological quality enrolling 820 participants (range 30 to 118). In 44.4% participants were female (range 37-59% in specific subgroups). CDI was assessed for internal carotid stenosis, diabetic retinopathy, glaucoma, and branch or central retinal vein occlusion diagnosis. There was insufficient data to pool the results for specific illnesses. For the assessments of ophthalmic arteries, mean sensitivity was 0.69 (range 0.27-0.96) with a corresponding mean specificity of 0.83 (range 0.70-0.96). Mean sensitivity of the central retinal artery assessments was 0.58 (range 0.31-0.84) and the corresponding mean specificity was 0.82 (range 0.63-0.94). Robust assessments of the diagnostic value of colour Doppler analysis remain uncommon, limiting the possibilities to extrapolate its true potential for clinical practice. PROSPERO 2014:CRD42014014027.

  1. 21 CFR 886.1375 - Bagolini lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bagolini lens. 886.1375 Section 886.1375 Food and... OPHTHALMIC DEVICES Diagnostic Devices § 886.1375 Bagolini lens. (a) Identification. A Bagolini lens is a device that consists of a plane lens containing almost imperceptible striations that do not obscure...

  2. 21 CFR 886.1435 - Maxwell spot.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Maxwell spot. 886.1435 Section 886.1435 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1435 Maxwell spot. (a) Identification. A Maxwell spot is an AC...

  3. Development of a reference system and a methodology for the calibration of ophthalmic applicators utilized in brachytherapy

    International Nuclear Information System (INIS)

    Oliveira, Mercia Liane de

    2005-01-01

    90 Sr+ 90 Y beta radiation sources are widely utilized in brachytherapy, in the treatment of superficial lesions of eyes and skin. According to international recommendations, these applicators should be specified in terms of the absorbed dose rate to water at the reference point (1 mm from the source surface, along its axis of symmetry). Two mini-extrapolation chambers were developed with adequate geometrical characteristics for the dosimetry of plane and concave 90 Sr+ 90 Y sources. These chambers have 3.0 cm of outer diameter and 11.3 cm of length. Aluminized polyester foils are used as entrance windows, and the collecting electrodes were made of graphited polymethylmethacrylate. The mini-chambers were tested in 90 Sr+ 90 Y radiation beams from a beta check source and plane and concave ophthalmic applicators. All results obtained show the usefulness of these chambers as reference primary standards for the calibration of 90 Sr+ 90 Y applicators. The previous calibration of the mini-chambers in relation to a standard ionization chamber or to a standard beta source is unnecessary. The minichamber with plane window showed utility for low energy X-rays too. In order to establish an alternative method for the calibration of beta radiation sources, different thermoluminescent materials were tested: LiF, CaF 2 :Mn, CaF 2 :Dy and CaS0 4 :Dy. For their characterization, the response reproducibility, calibration curves, TL response as a function of the source-detector distance, transmission factors and the linearity of the sample response were determined. The calibration procedures of ophthalmic applicators were established utilizing the ionometric technique and thermoluminescence dosimetry. (author)

  4. Dosimetric Benefit of a New Ophthalmic Radiation Plaque

    Energy Technology Data Exchange (ETDEWEB)

    Marwaha, Gaurav, E-mail: marwahg2@ccf.org [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Wilkinson, Allan [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Bena, James [Department of Quantitative Health Sciences, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Macklis, Roger [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Singh, Arun D. [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Department of Ophthalmic Oncology, Cole Eye Institute, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States)

    2012-12-01

    Purpose: To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. Methods and Materials: One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in this study. These treatment plans were generated with the use of Bebig Plaque Simulator treatment-planning software, both for COMS plaques and for EP917 plaques using I-125. Dose distributions were calculated for a prescription of 85 Gy to the tumor apex. Doses to the optic disc, opposite retina, lens, and macula were obtained, and differences between the 2 groups were analyzed by standard parametric methods. Results: When compared with the COMS plaques, the EP917 plaques used fewer radiation seeds by an average difference of 1.94 (P<.001; 95% confidence interval [CI], -2.8 to -1.06) and required less total strength of radiation sources by an average of 17.74 U (air kerma units) (P<.001; 95% CI, -20.16 to -15.32). The total radiation doses delivered to the optic disc, opposite retina, and macula were significantly less by 4.57 Gy, 0.50 Gy, and 11.18 Gy, respectively, with the EP917 plaques vs the COMS plaques. Conclusion: EP917 plaques deliver less overall radiation exposure to critical vision structures than COMS treatment plaques while still delivering the same total therapeutic dose to the tumor.

  5. Dosimetric Benefit of a New Ophthalmic Radiation Plaque

    International Nuclear Information System (INIS)

    Marwaha, Gaurav; Wilkinson, Allan; Bena, James; Macklis, Roger; Singh, Arun D.

    2012-01-01

    Purpose: To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. Methods and Materials: One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in this study. These treatment plans were generated with the use of Bebig Plaque Simulator treatment-planning software, both for COMS plaques and for EP917 plaques using I-125. Dose distributions were calculated for a prescription of 85 Gy to the tumor apex. Doses to the optic disc, opposite retina, lens, and macula were obtained, and differences between the 2 groups were analyzed by standard parametric methods. Results: When compared with the COMS plaques, the EP917 plaques used fewer radiation seeds by an average difference of 1.94 (P<.001; 95% confidence interval [CI], −2.8 to −1.06) and required less total strength of radiation sources by an average of 17.74 U (air kerma units) (P<.001; 95% CI, −20.16 to −15.32). The total radiation doses delivered to the optic disc, opposite retina, and macula were significantly less by 4.57 Gy, 0.50 Gy, and 11.18 Gy, respectively, with the EP917 plaques vs the COMS plaques. Conclusion: EP917 plaques deliver less overall radiation exposure to critical vision structures than COMS treatment plaques while still delivering the same total therapeutic dose to the tumor.

  6. Development of irradiation support devices for production of brachytherapy seeds

    International Nuclear Information System (INIS)

    Mattos, Fabio R.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos A.; Souza, Carla D.; Moura, Joao A.; Peleias Junior, Fernando S.; Karan Junior, Dib; Feher, Anselmo; Oliveira, Tiago B.; Benega, Marcos A.G.

    2013-01-01

    Ophthalmic tumors treatment with brachytherapy sources has been widely used as a primary or secondary therapy for non-malignant or malignant tumors, for example, choroid melanoma, and retinoblastoma. Ruthenium-106, Iodine-125, Palladium -103, Gold-198 and Iridium-192, are some radionuclides that can be applied for treatment of ocular tumors. These sources are in small sizes (a few millimeters) and different shapes (rods, wires, disks). To ensure high accuracy during treatment, they are positioned in eye applicators, specially designed to fit on the surface of tumor. The Nuclear and Energy Research Institute (IPEN/CNEN) in a partnership with Paulista Medicine School (UNIFESP) created a project that aims to develop a prototype of Iridium-192 seeds for treatment of eye cancer. This seed consists in a core of Ir -Pt alloy (20%-80%) with a length of 3 mm, to be activated in IPEN's IEA-R1 Reactor, and a titanium capsule sealing the core. It was imperative to develop a sustainer device for irradiation. This piece is used to avoid overlapping of one cores and, therefore, avoiding the 'shadow effect' that does not allow full activation of each core due to the high density. (author)

  7. Reversal in the Diameter of the Superior Ophthalmic Vein after an Epidural Blood Patch in a Case of Spontaneous Intracranial Hypotension

    International Nuclear Information System (INIS)

    Hsiao, Chen Yu; Tsai, Yuh Feng

    2011-01-01

    Spontaneous intracranial hypotension (SIH) is caused by single or multiple cerebrospinal fluid (CSF) leaks in the spine with the prototypical symptom of postural headache. One of the characteristic MRI features in SIH is intracranial venous engorgement. This report presents a case of SIH with engorgement of the bilateral superior ophthalmic veins (SOVs) which resume their normal diameters by the third day of successful epidural blood patches (EBPs). We define this phenomenon as the 'reversal of the SOV' sign.

  8. Clinical use of gatifloxacin ophthalmic solution for treatment of bacterial conjunctivitis

    Directory of Open Access Journals (Sweden)

    Cervantes LJ

    2011-04-01

    Full Text Available Lorenzo J Cervantes, Francis S MahDepartment of Ophthalmology, Cornea and External Disease, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USAAbstract: Bacterial conjunctivitis is a common infectious disease of the eye, characterized by conjunctival hyperemia, eyelid edema, and purulent discharge. Although the prevalence and incidence are not well reported, bacterial conjunctivitis represents one of the most frequent causes of patient visits to both primary care physicians and ophthalmologists. Most cases of nongonococcal and nonchlamydial bacterial conjunctivitis are self-limiting and may resolve without intervention. There is a place for treatment, however, which allows for a shorter time to clinical and microbiological resolution which may decrease the mild morbidity, decrease health care costs of visits and potential complications, return patients back to school or the work force, and limit the potential spread of this communicable infection. Gatifloxacin ophthalmic solution is a broad spectrum 8-methoxyfluroroquinolone bactericidal antibiotic, with good activity against Staphylococcus aureus, Streptococcus species, and Gram-negative pathogens. It also has a relatively good resistance profile, making it a more than adequate choice in the treatment of bacterial conjunctivitis when therapy is warranted.Keywords: gatifloxacin, Zymar®, Zymaxid®, bacterial conjunctivitis

  9. Toward the development of a low-cost laser Doppler module for ophthalmic microscopes

    Science.gov (United States)

    Cattini, Stefano; Rovati, Luigi

    2012-03-01

    A laser Doppler module easily integrated into a commercial ophthalmic microscope is proposed. Such setup adds flow measurement capability to standard visual inspection of the fundus. The proposed instrument may provide important clinical information such as the detection of vessel occlusion provided by surgical treatments (i.e. photocoagulation). The measuring system is based on a self-mixing laser diode Doppler flowmeter (SM-DF). Reduced costs, easy implementation and small size represent the main features of SM-DF. Moreover, this technique offers the advantage to have the excitation and measurement beams spatially overlapped, thus both overcoming the alignment difficulty of traditional laser Doppler flowmeter and, well fitting with to limited optical aperture of the pupil. Thanks to an on-board DSP-microcontroller, the optoelectronic module directly estimates the blood flow; USB connection and an ad-hoc developed user-friendly software interface allow displaying the result on a personal computer. Preliminary test demonstrates the applicability of the proposed measuring system.

  10. Optimising concentrations of antimicrobial agents in pharmaceutical preparations: Case of an oral solution of glycerol and an ophthalmic solution containing cysteamine.

    Science.gov (United States)

    Chan Hew Wai, A; Becasse, P; Tworski, S; Pradeau, D; Planas, V

    2014-11-01

    In the context of current distrust of antimicrobial preservatives, the quantities of these substances in two pharmaceutical formulas were studied: an ophthalmic solution of cysteamine preserved benzalkonium chloride at 1mg/5mL and Glycerotone(®) preserved with sorbic acid at 0.1g/100g. The purpose of this work was to verify that a reduction of the quantities of preservative continues to fulfil the requirements for antimicrobial preservation. The Test of efficacy of antimicrobial preservation, section 5.1.3 of the 8th edition of the European Pharmacopoeia, was carried out on each formulation prepared with decreasing quantities of preservative. The results show that formulations whose preservative concentration was reduced by a factor of four remained compliant with standards. It is to be noted that in formulas without preservative, fungal growth was observed in both the solution of Glycerotone(®) and the ophthalmic solution containing cysteamine. Although there is no question that an antimicrobial preservative is necessary, the quantity of preservative can be reduced without deteriorating the quality of the pharmaceutical product but the minimal effective concentration remains to be determined. The formulations of many pharmaceutical products should therefore be examined in order to limit the quantities of preservative while continuing to guarantee patient's safety. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  11. Evaluation the index of ophthalmic arteries in diabetic patients with retinopathy compared to diabetic patients without retinopathy using color Doppler ultrasound

    Directory of Open Access Journals (Sweden)

    Mohammad Ghasem Hanafi

    2016-12-01

    Full Text Available Diabetic retinopathy is the most common eye complication in diabetic patients that early detection of this complication is essential. The aim of this study was to evaluate ophthalmic artery index in diabetic retinopathy by Doppler ultrasound. . In this cross-sectional study, 64 patients were studied in 4 groups (healthy, diabetic without retinopathy, background retinopathy and proliferative retinopathy. Resistance index (RI and Pulsatile Index (PI were assessed by color Doppler ultrasound. The obtained data were analyzed by ANOVA and chi-square test and ROC curve. RI in diabetic patients with proliferative retinopathy has the highest mean (0.83 and the lowest mean was observed in healthy subjects (0.54 (P <0.001 as well as in PI, the highest rate was in diabetic patients with proliferative retinopathy (1.41 and the lowest was in healthy subjects (0.92 (P <0.001. The results of our study showed that the sensitivity, specificity, positive and negative predictive values and overall accuracy of RI and PI in diabetic patients with proliferative retinopathy in the best cut-off points (0.645 and 1.0175 respectively were 100%.Ophthalmic artery index RI and PI was significantly increased in patients with diabetic retinopathy and the sensitivity and specificity for detection retinopathy was 100%. Color Doppler ultrasound method is more efficient for screening diabetic patients with retinopathy.

  12. A method for the calibration of concave sup 90 Sr+ sup 90 Y ophthalmic applicators

    Energy Technology Data Exchange (ETDEWEB)

    Soares, C G [National Inst. of Standards and Technology, Gaithersberg, MD (United States). Ionizing Radiation Div.

    1992-04-01

    At the Amersham Laboratory (Amersham, UK) absorbed-dose rate in tissue at a depth of 7 mg cm{sup -2} from curved ophthalmic applicators is measured with calibrated scintillator probes (Amersham International 1979, Sinclair and Trott 1956). The probes are approximately 3 mm in diameter, 0.5 mm thick and are covered with 7 mg cm{sup -2} of aluminium. They are calibrated using standard sources whose dose rate has been determined using an extrapolation chamber equipped with a 3 mm diameter collecting electrode. Crucial to this technique is the availability of well calibrated sources of nearly the same geometry and dose rate as the source to be calibrated. A technique is presented here which yields accurate measurement of the surface absorbed-dose rate in a very simple and straightforward fashion. (author).

  13. Endovascular treatment of a cavernous sinus dural arteriovenous fistula by transvenous embolisation through the superior ophthalmic vein via cannulation of a frontal vein

    International Nuclear Information System (INIS)

    Venturi, C.; Bracco, S.; Cerase, A.; Gennari, P.; Lore, F.; Polito, E.; Casasco, A.E.

    2003-01-01

    We describe a new approach for transvenous embolisation of cavernous sinus dural arteriovenous fistulae through the superior ophthalmic vein (SOV), i.e., via percutaneous cannulation of a frontal vein. Modern neurointerventional angiographic materials make it possible to reach the SOV in this way without puncturing it in the orbit or a surgical exposure. Orbital phlebography should still be in the repertoire of interventional neuroradiology units in large centres. (orig.)

  14. Efficacy and safety of retinol palmitate ophthalmic solution in the treatment of dry eye: a Japanese Phase II clinical trial

    Directory of Open Access Journals (Sweden)

    Toshida H

    2017-06-01

    Full Text Available Hiroshi Toshida,1 Toshinari Funaki,2 Koichi Ono,3 Nobuhito Tabuchi,4 Sota Watanabe,4 Tamotsu Seki,5 Hiroshi Otake,6 Takuji Kato,7 Nobuyuki Ebihara,8 Akira Murakami2 1Department of Ophthalmology, Juntendo University Shizuoka Hospital, Shizuoka, 2Department of Ophthalmology, Juntendo University Graduate School of Medicine, 3Department of Ophthalmology, Juntendo Tokyo Koto Geriatric Medical Center, Tokyo, 4Pharmaceutical Research Laboratories, Lion Corporation, Kanagawa, 5Tamagawa Eye Clinic, Tokyo, 6Otake Eye Clinic, Kanagawa, 7Kato Eye Clinic, Tokyo, 8Department of Ophthalmology, Juntendo University Urayasu Hospital, Chiba, Japan Purpose: The purpose of this study was to investigate the efficacy and safety of the administration of retinol palmitate (VApal ophthalmic solution (500 IU/mL for the treatment of patients with dry eye. Patients and methods: This study included 66 patients with dry eye. After a 2-week washout period, patients were randomized (1:1 into either a VApal ophthalmic solution or a placebo group, and a single drop of either solution was administered six times daily for 4 weeks. Efficacy measures were 12 subjective symptoms, rose bengal (RB and fluorescein staining scores, tear film breakup time, and tear secretion. Safety measures included clinical blood and urine analyses and adverse event recordings. Results: In comparisons of the two groups, the mean change in RB staining score from baseline was significantly lower in the VApal group at 2 and 4 weeks (P<0.05 and P<0.01, respectively. Furthermore, the fluorescein clearance rate (fluorescein staining score was significantly higher in the VApal group at 4 weeks (P<0.05. The VApal group showed a significant improvement in blurred vision at 1 and 2 weeks (P<0.01 and P<0.05, respectively, and the mean change in the total score for subjective symptoms from baseline was significantly lower in the VApal group at 1 week (P<0.05. In before- and after-intervention comparisons, the

  15. Infraorbital nerve involvement on magnetic resonance imaging in European patients with IgG4-related ophthalmic disease: a specific sign

    Energy Technology Data Exchange (ETDEWEB)

    Soussan, J. Ben; Sadik, J.C.; Savatovsky, J.; Heran, F.; Lecler, A. [Fondation Ophtalmologique Adolphe de Rothschild, Department of Radiology, Paris (France); Deschamps, R. [Fondation Ophtalmologique Adolphe de Rothschild, Department of Neurology, Paris (France); Deschamps, L. [Bichat Hospital, APHP, Department of Pathology, Paris (France); Puttermann, M. [Necker-Enfants Malades Hospital, APHP, Department of Pathology, Paris (France); Zmuda, M.; Galatoire, O. [Fondation Ophtalmologique Adolphe de Rothschild, Department of Orbitopalpebral Surgery, Paris (France); Picard, H. [Fondation Ophtalmologique Adolphe de Rothschild, Clinical Research Unit, Paris (France)

    2017-04-15

    To measure the frequency of infraorbital nerve enlargement (IONE) on magnetic resonance imaging (MRI) in European patients suffering from an IgG4-related ophthalmic disease (IgG4-ROD) as compared to patients suffering from non-IgG4-related ophthalmic disease (non-IgG4-ROD). From January 2006 through April 2015, 132 patients were admitted for non-lymphoma, non-thyroid-related orbital inflammation. Thirty-eight had both pre-therapeutic orbital MRI and histopathological IgG4 immunostaining. Fifteen patients were classified as cases of IgG4-ROD and 23 patients as cases of non-IgG4-ROD. Two readers performed blinded analyses of MRI images. The main criterion was the presence of an IONE, defined as the infraorbital nerve diameter being greater than the optic nerve diameter in the coronal section. IONE was present in 53% (8/15) of IgG4-ROD cases whereas it was never present (0/23) in cases of non-IgG4-ROD (P < 0.0001). IONE was only present in cases where, on MRI, the inflammation of the inferior quadrant was present and in direct contact with the ION canal. In European patients suffering from orbital inflammation, the presence of IONE on an MRI is a specific sign of IgG4-ROD. Recognition of this pattern may facilitate the accurate diagnosis for clinicians and allow for the adequate management and appropriate care of their patients. (orig.)

  16. Infraorbital nerve involvement on magnetic resonance imaging in European patients with IgG4-related ophthalmic disease: a specific sign

    International Nuclear Information System (INIS)

    Soussan, J. Ben; Sadik, J.C.; Savatovsky, J.; Heran, F.; Lecler, A.; Deschamps, R.; Deschamps, L.; Puttermann, M.; Zmuda, M.; Galatoire, O.; Picard, H.

    2017-01-01

    To measure the frequency of infraorbital nerve enlargement (IONE) on magnetic resonance imaging (MRI) in European patients suffering from an IgG4-related ophthalmic disease (IgG4-ROD) as compared to patients suffering from non-IgG4-related ophthalmic disease (non-IgG4-ROD). From January 2006 through April 2015, 132 patients were admitted for non-lymphoma, non-thyroid-related orbital inflammation. Thirty-eight had both pre-therapeutic orbital MRI and histopathological IgG4 immunostaining. Fifteen patients were classified as cases of IgG4-ROD and 23 patients as cases of non-IgG4-ROD. Two readers performed blinded analyses of MRI images. The main criterion was the presence of an IONE, defined as the infraorbital nerve diameter being greater than the optic nerve diameter in the coronal section. IONE was present in 53% (8/15) of IgG4-ROD cases whereas it was never present (0/23) in cases of non-IgG4-ROD (P < 0.0001). IONE was only present in cases where, on MRI, the inflammation of the inferior quadrant was present and in direct contact with the ION canal. In European patients suffering from orbital inflammation, the presence of IONE on an MRI is a specific sign of IgG4-ROD. Recognition of this pattern may facilitate the accurate diagnosis for clinicians and allow for the adequate management and appropriate care of their patients. (orig.)

  17. Multiscale modelling approach combining a kinetic model of glutathione metabolism with PBPK models of paracetamol and the potential glutathione-depletion biomarkes ophthalmic acid and 5-oxoproline in humans and rats

    NARCIS (Netherlands)

    Geenen, S.; Yates, J.W.T.; Kenna, J.G.; Bois, F.Y.; Wilson, I.D.; Westerhoff, H.V.

    2014-01-01

    A key role of the antioxidant glutathione is detoxification of chemically reactive electrophilic drug metabolites within the liver. Therefore glutathione depletion can have severe toxic consequences. Ophthalmic acid and 5-oxoproline are metabolites involved in glutathione metabolism, which can be

  18. Design and construction of ophthalmic simulators for clinical applications

    International Nuclear Information System (INIS)

    Sanchez, Andrea

    2006-01-01

    This work presents a calculational methodology for dose determination in human eye structures, such as: sclera, choroid, retina, lens, vitreous body, optic nerve and disc, and cornea, as well as tumor due to treatment to the eye plaques. A human eye model was constructed taking into consideration its main structural and dimension characteristics. Beyond that a mathematical model for the Co-60 and 1-125 plaques with all geometric details were built employing the MCNP-4C code. This model is able to calculate the axial and radial doses in any point of the eye and for each of its structures. An acrylic eye simulator was also built with the aim to obtain experimental results for the both model validations. This simulator is made of an acrylic sphere split into foils of 1 mm thickness which allow the introduction of a radiographic film to measure the axial and radial doses. The experimental data were used to validate the MCNP-4C results. The data from the mathematical model will serve as the basis to build a data bank for all the eye structures allowing different position and sizes of tumor as well as the replacement of all ophthalmic plaques used in the treatment. This data bank will be the principal part for the construction of a national software for the dose calculation and can be of great help for a reliable treatment system planning in radiotherapy/brachytherapy. (author)

  19. The Influence of Early Ophthalmic Hospitals on the Journal.

    Science.gov (United States)

    Pathipati, Akhilesh S; Tsai, James C

    2018-05-09

    To consider the American Journal of Ophthalmology's (AJO's) role not only as a forum to describe clinical and scientific advances but also as a record of institutional histories. We used the New York Eye and Ear Infirmary of Mount Sinai, the Massachusetts Eye and Ear Infirmary, and the Wills Eye Hospital as case studies on the Journal's role in documenting the people and organizations that have moved ophthalmology forward. Perspective. Using the ScienceDirect database, we conducted a literature search to gather all mentions of the 3 eye hospitals in the Journal's archives from 1918 to 2018. We evaluated those search results to identify a few of the individuals and articles that highlight how the history of eye institutions are reflected in the AJO. Searches for the aforementioned 3 hospitals yielded over 3400 results in Journal archives. These included articles on their histories, proceedings from clinical case conferences, profiles of prominent surgeons, and information about educational offerings, among others. Many of those articles were written by physicians from those institutions who also served on the AJO's editorial board or had a long history of publishing in the Journal. The AJO has played a crucial role in the last 100 years as a register of ophthalmic history. The New York Eye and Ear Infirmary of Mount Sinai, Massachusetts Eye and Ear Infirmary, and Wills Eye Hospital provide 3 examples of how that role manifests. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Transvenous embolization of indirect carotid-cavernous fistula via upper ophthalmic/facial vein - Case report and literature review

    International Nuclear Information System (INIS)

    Sirakov, S.; Penkov, M.; Sirakov, A.; Kamenov, B.; Todorov, Y.; Ninov, K.; Bachvarov, Ch.

    2015-01-01

    Indirect carotid-cavernous fistula or dural arterio-venous fistula of cavernous sinus is relatively rare pathologic finding. Different classifications of carotid-cavernous fistulae are proposed. Now days more and more they are treated by endovascular approach. A case of authors' practice of transvenous embolization of carotid-cavernous fistula via upper ophthalmic vein in 52 year old female is presented with review of the literature. A week later ocular symptoms of the patient regressed. Control angiography at the third month follow up does not visualize fistula. The transvenous approach in management of carotid cavernous fistulae is safe and effective in cases direct arterial approach is absent or technically impossible. Key words: Indirect Carotid-Cavernous Fistula. Embolization. Transvenous Approach

  1. Ophthalmic nepafenac use in the Netherlands and Denmark.

    Science.gov (United States)

    Margulis, Andrea V; Houben, Eline; Hallas, Jesper; Overbeek, Jetty A; Pottegård, Anton; Torp-Pedersen, Tobias; Perez-Gutthann, Susana; Arana, Alejandro

    2017-08-01

    To describe nepafenac use in the Netherlands and Denmark with reference to its approved indications. For context, we also describe the use of ketorolac and diclofenac. We identified users in the PHARMO Database Network (the Netherlands, 2008-2013) and the Danish national health registers (Denmark, 1994-2014). We described prevalence of cataract surgery and duration of use in patients with cataract surgery with and without diabetes. In the Netherlands, 9530 nepafenac users (mean age, 71 years; 60% women) contributed 12 691 therapy episodes, of which 21% had a recently recorded cataract surgery. Of 2266 episodes in adult non-diabetic patients with cataract surgery, 60% had one bottle dispensed (treatment duration ≤21 days). Of 441 episodes in adult diabetic patients with cataract surgery, 90% had up to two bottles dispensed (≤60 days). Denmark had 60 403 nepafenac users (mean age, 72 years; 58% women) and 73 648 episodes (41% had recorded cataract surgery). Of 26 649 nepafenac episodes in adult non-diabetic patients with cataract surgery, 92% had one bottle dispensed. Of 3801 episodes in adult diabetic patients with cataract surgery, 99.8% had up to two bottles dispensed. Use patterns of nepafenac, ketorolac and diclofenac were roughly similar in the Netherlands, but not in Denmark. Less than half of therapy episodes were related to cataract surgery; around 90% of episodes with surgery were within the approved duration. Underrecording of ophthalmic conditions and procedures was a challenge in this study. © 2017 The Authors Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.

  2. Immunomodulatory effect of the topical ophthalmic Janus kinase inhibitor tofacitinib (CP-690,550) in patients with dry eye disease.

    Science.gov (United States)

    Huang, Jing-Feng; Yafawi, Rolla; Zhang, Min; McDowell, Michael; Rittenhouse, Kay D; Sace, Frederick; Liew, Shiao Hui Melissa; Cooper, Scott R; Pickering, Eve H

    2012-07-01

    To evaluate the immunomodulatory effect of topical ophthalmic tofacitinib (CP-690,550) after an 8-week treatment period in patients with dry eye disease (DED). Biomarker substudy of a phase 1/2 prospective, randomized, vehicle- and comparator-controlled clinical trial (NCT00784719). A total of 82 patients with moderate to severe DED enrolled. Patients received 1 of 5 doses of tofacitinib (0.0003%, 0.001%, 0.003%, or 0.005% twice daily [BID] or 0.005% once daily [QD]), active comparator (cyclosporine ophthalmic emulsion, 0.05% [Restasis, Allergan Inc., Irvine, CA]), or vehicle control BID for 8 weeks. Conjunctival impression cytology and tear fluid samples were collected at baseline and after an 8-week treatment period. Conjunctival cells were analyzed by flow cytometry for human leukocyte antigen DR-1 (HLA-DR). Tear fluids were analyzed by microsphere-based immunoassays for tear levels of cytokines and inflammation markers. Reduction in inflammation assessed by change from baseline in conjunctival cell surface level of HLA-DR and tear level of cytokines and inflammation markers. At week 8, a decrease in conjunctival cell surface expression of HLA-DR was observed in patients treated with tofacitinib 0.005% QD and 0.003% BID: 71% and 67% of baseline, respectively, compared with 133% of baseline in patients treated with vehicle (P=0.023 and P=0.006, compared with vehicle, respectively). Matrix metalloproteinase (MMP)-3 in tears was reduced from baseline at week 8 (40% of baseline, P=0.035) in the tofacitinib 0.005% QD group, whereas the vehicle group showed 77% of baseline (P>0.20). Interleukin (IL)-1β in tears was 36% of baseline (P=0.053) in the tofacitinib 0.005% QD group and 95% of baseline (P > 0.20) in the vehicle group. Several other cytokines and inflammation markers in tears, including MMP-9, IL-15, IL-17A, and IL-12p70, were markedly reduced in the tofacitinib 0.005% QD group but not the vehicle group. There was an association between the changes in HLA

  3. Outcomes after cataract surgery in eyes with pseudoexfoliation: Results from the Veterans Affairs Ophthalmic Surgery Outcomes Data Project.

    Science.gov (United States)

    Turalba, Angela; Cakiner-Egilmez, Tulay; Payal, Abhishek R; Gonzalez-Gonzalez, Luis A; Chomsky, Amy S; Vollman, David E; Baze, Elizabeth F; Lawrence, Mary G; Daly, Mary K

    2017-02-01

    To compare clinical outcomes of cataract surgery in eyes with and without pseudoexfoliation (PXF). Retrospective deidentified data analysis. A total of 123 PXF and 4776 non-PXF eyes of patients who underwent cataract surgery. We compared data on visual acuity, Visual Function Questionnaire (VFQ)-based quality of life, and complications in PXF and non-PXF eyes from the Veterans Affairs (VA) Ophthalmic Surgery Outcomes Data Project across 5 VA medical centres. Pupillary expansion devices were used in 31 (25.2%) PXF cases and 398 (8.4%) non-PXF cases (p < 0.0001). Capsular tension rings were used in 6 (4.9%) PXF cases and 55 (1.2%) non-PXF cases (p < 0.004). The following complications occurred more frequently in PXF cases: zonular dehiscence without vitrectomy (4 [3.3%] PXF cases vs 40 [0.8%] non-PXF cases p = 0.02), persistent inflammation (28 [24.1%] vs 668 [14.5%]; p = 0.007), and persistent intraocular pressure elevation (5 [4.3%] vs 68 [1.5%]; p = 0.03). Best corrected visual acuity (BCVA) improved in both groups after 1 month, but 87 (83.7%) PXF cases achieved postoperative BCVA better than or equal to 20/40 compared to 3991 (93.8%) non-PXF cases (p = 0.0003). There was no significant difference in the postoperative composite VFQ scores between PXF (82.1 ± 16.9) and non-PXF cases (84.2 ± 16.8, p = 0.09). Several complications occurred more frequently in the PXF group compared to the non-PXF group, and fewer PXF cases achieved BCVA better than or equal to 20/40. Despite this, both groups experienced similar improvement in vision-related quality of life after cataract surgery. Published by Elsevier Inc.

  4. [Outbreak of hospital acquired Legionnaires' disease in patients of ophthalmic ward. Nosocomial Legionella infections for the first time observed in Poland].

    Science.gov (United States)

    Stypułkowska-Misiurewicz, Hanna; Pancer, Katarzyna; Krogulska, Bozena; Matuszewska, Renata

    2007-01-01

    The aim of the paper is to describe the criteria used for identification of first and so far the only one outbreak of hospital bacterial infections due to L. pneumophila. The infected persons were patients hospitalized at ophthalmic ward for more than 10 days. Four patients were found ill among 27 hospitalized (15%) at ophthalmic ward and 3 of them died (75%) in spite treatment in intensive care unit. The source of infection was found in the hospital hot water system. It was shown that L. pneumophila sg 1 and sg 2-14 were settled in the tanks and pipelines of hot water installations. The high number of L. pneumophila sg I and sg 2-14 colony forming units (> 10 000 cfu /100 ml) were found in the water specimens taken from the hospital water system, showing the high risk of Legionella infection for patients. Cleaning and disinfection of hot water system was repeated three times using composition every time modified as stronger mechanical, thermal and chemical methods. Complete elimination of Legionella from hot water system was achieved after cutting off deadlegs of water and replacement of both old hot water reservoirs with new ones. Collected experience served for preparation of guidelines for control and prevention of Legionella infections in hospital buildings, published on National Institute of Hygiene web site A month later Polish Ministry of Health published the Directives concerning the quality of drinking water to which the control of Legionella infection has been included.

  5. The effects of variations in the density and composition of eye materials on ophthalmic brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Asadi, Somayeh; Masoudi, Seyed Farhad; Shahriari, Majid

    2012-01-01

    In ophthalmic brachytherapy dosimetry, it is common to consider the water phantom as human eye anatomy. However, for better clinical analysis, there is a need for the dose determination in different parts of the eye. In this work, a full human eye is simulated with MCNP-4C code by considering all parts of the eye, i.e., the lens, cornea, retina, choroid, sclera, anterior chamber, optic nerve, and bulk of the eye comprising vitreous body and tumor. The average dose in different parts of this full model of the human eye is determined and the results are compared with the dose calculated in water phantom. The central axes depth dose and the dose in whole of the tumor for these 2 simulated eye models are calculated as well, and the results are compared.

  6. Chitosan/alginate based multilayers to control drug release from ophthalmic lens.

    Science.gov (United States)

    Silva, Diana; Pinto, Luís F V; Bozukova, Dimitriya; Santos, Luís F; Serro, Ana Paula; Saramago, Benilde

    2016-11-01

    In this study we investigated the possibility of using layer-by-layer deposition, based in natural polymers (chitosan and alginate), to control the release of different ophthalmic drugs from three types of lens materials: a silicone-based hydrogel recently proposed by our group as drug releasing soft contact lens (SCL) material and two commercially available materials: CI26Y for intraocular lens (IOLs) and Definitive 50 for SCLs. The optimised coating, consisting in one double layer of (alginate - CaCl2)/(chitosan+glyoxal) topped with a final alginate-CaCl2 layer to avoid chitosan degradation by tear fluid proteins, proved to have excellent features to control the release of the anti-inflammatory, diclofenac, while keeping or improving the physical properties of the lenses. The coating leads to a controlled release of diclofenac from SCL and IOL materials for, at least, one week. Due to its high hydrophilicity (water contact angle≈0) and biocompatibility, it should avoid the use of further surface treatments to enhance the useŕs comfort. However, the barrier effect of this coating is specific for diclofenac, giving evidence to the need of optimizing the chemical composition of the layers in view of the desired drug. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Ophthalmic parameters in adult lowland paca (Cuniculus paca) raised in captivity.

    Science.gov (United States)

    Balthazar da Silveira, Camila P; Lima, Tiago B; Crivelaro, Roberta M; de Lacerda, Luciana C C; Pádua, Ivan R M; Renzo, Roberta; de Barros Sobrinho, Alexandre A F; Oliveira, Fabrício S; Aldrovani, Marcela; Laus, José L

    2018-01-01

    To investigate the ophthalmic parameters of lowland pacas, including the anatomic features, tear production, intraocular pressure, central corneal thickness, and morphology of the corneal endothelium. Thirteen adult, anesthetized Cuniculus paca. Eyes were evaluated using slit-lamp biomicroscopy, the Schirmer tear test I, digital applanation tonometry, binocular indirect ophthalmoscopy, and noncontact specular microscopy. The biomicroscopy findings showed blue/brown pigmented bulbar conjunctivae, well-developed cilia (only in the upper eyelid margin), superior and inferior lacrimal puncta, brown irides, round pupils, and vestiges of the nictitating membrane. The results of the Schirmer tear test I revealed (mean ± SD) a lacrimation rate of 4.10 ± 0.44 mm/min. The intraocular pressure was 6.34 ± 0.43 mmHg. Central corneal thickness measured by specular microscopy was 0.35 ± 0.01 mm. The mean values of density, hexagonality, and the area of the endothelial cells were 2083.15 ± 42.47 cells/mm 2 , 67.07 ± 3.30%, and 486.30 ± 9.56 μm 2 , respectively. The ocular parameters defined in this study may be used for reference in future studies and might also contribute to therapeutic approaches appropriate to this species. © 2017 American College of Veterinary Ophthalmologists.

  8. Risk Factors for Cataract After Palladium-103 Ophthalmic Plaque Radiation Therapy

    International Nuclear Information System (INIS)

    Finger, Paul T.; Chin, Kimberly J.; Yu Guopei; Patel, Neil S.

    2011-01-01

    Purpose: To examine how tumor characteristics and dose affect cataract development after plaque radiation therapy. Methods and Materials: Three hundred and eighty-four patients were diagnosed with uveal melanoma and treated with palladium-103 ( 103 Pd) plaque radiation therapy. Of these, 282 (74%) inclusion met exclusion criteria for follow-up time, tumor location, and phakic status. Then patient-, ophthalmic-, and radiation-specific factors (patient age, diabetes, hypertension, tumor location, tumor dimensions, and lens dose) were examined (by a Cox proportional regression model) as predictors for the development of radiation-related cataract. Results: Radiation cataract developed in 76 (24%) of patients at a mean follow-up of 39.8 months (range, 1-192). Patients with anteriorly located tumors were noted to have a higher incidence of cataract at 43.0% (43 of 100 patients) vs. 18.1% (33 cataracts per 182 patients) for posteriorly located tumors (p <0.0001). However, multivariate Cox proportional modeling showed that increasing patient age at time of treatment (p for trend = 0.0003) and higher lens dose (p for trend = 0.001) were the best predictors (biomarkers) for radiation cataract. Conclusions: Although anterior tumor location, greater tumor height, and increased patient age (at treatment) were associated with significantly greater risk for radiation cataract, dose to lens was the most significant factor.

  9. Ophthalmic effects of petroleum dispersant exposure on common murres (Uria aalge): An experimental study.

    Science.gov (United States)

    Fiorello, Christine V; Freeman, Kate; Elias, Becky A; Whitmer, Emily; Ziccardi, Michael H

    2016-12-15

    The safety of chemical dispersants used during oil spill responses is largely unknown in birds. We captured common murres in Monterey Bay, CA and exposed them to Corexit EC9500a, crude oil, or a combination in artificial seawater. We performed ophthalmic examinations and measured intraocular pressures and tear production before and after exposure. Loglinear analysis found that exposure to oil or dispersant was related to the development of conjunctivitis and corneal ulcers. Odds ratios for birds exposed to oil or dispersant were positive and significant for the development of conjunctivitis, while odds ratios for the development of corneal ulcers were positive and significant only for birds exposed to a high concentration of oil. Ocular exposure to dispersants and petroleum in seabirds may cause conjunctivitis and may play a role in the development of corneal ulcers. These results have implications for policymakers who develop protocols for the use of dispersants during marine oil spills. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Out of hours ophthalmic surgery: a UK national survey.

    Science.gov (United States)

    O'Colmain, U; Wright, M; Bennett, H; MacEwen, C J

    2013-03-01

    There have been significant changes in the management of out of hours services in ophthalmology recently. The European Working Time Directive (EWTD) and economic measures have anecdotally reduced the availability of staff and facilities outside normal working hours, and there have been various responses to the provision of emergency surgical care. There are disparate attitudes to the optimum management of the emergency surgical case. We sought to establish a nationwide picture of the management of out of hours surgery. A questionnaire was distributed to every consultant ophthalmologist working in the NHS and registered with the Royal College of Ophthalmologists (n=947). Information was requested regarding departmental and personal policies, local facilities, and personal beliefs regarding emergency surgery. A total of 440 (46.5%) questionnaires were returned from 155 units; 18.7% of the units had no out of hours services or no operating facilities. Sixty-three percent of units reported a local policy regarding a time after which patients should not be taken to theatre. For 57%, this time began between 2100 hours and midnight. The most common reasons for not operating after a certain time were 'belief that delay does not significantly affect the outcome' (41.6%), 'delayed access to theatre due to competition with other surgical specialities' (40%), and 'no specialist ophthalmic-theatre nursing input' (32.7%). We report the first nationwide study on out of hours ophthalmological surgical working practices. This demonstrates variation in work patterns. It is significant to patients and ophthalmologists that there should be units in United Kingdom without full local facilities and staff.

  11. Interleukin-6 levels in the conjunctival epithelium of patients with dry eye disease treated with cyclosporine ophthalmic emulsion.

    Science.gov (United States)

    Turner, K; Pflugfelder, S C; Ji, Z; Feuer, W J; Stern, M; Reis, B L

    2000-07-01

    To evaluate interleukin-6 (IL-6) levels in the conjunctival epithelium of patients with moderate to severe dry eye disease before and after treatment with cyclosporin A ophthalmic emulsion (CsA) or its vehicle. Conjunctival cytology specimens were obtained from a subset of patients enrolled in a 6-month randomized, double-masked clinical trial of the efficacy and safety of topical CsA at baseline and after 3 and 6 months of B.I.D. treatment with 0.05% cyclosporine emulsion (n = 13), 0.1% cyclosporine emulsion (n = 8), or vehicle (n = 10). RNA was extracted and a competitive reverse transcriptase polymerase chain reaction (RT-PCR) was used to evaluate the levels of mRNA encoding the inflammatory cytokine IL-6 and a housekeeping gene, G3PDH. Levels of IL-6 and G3PDH were measured and compared. There was no change from baseline in the level of G3PDH after 3 or 6 months in any group. IL-6 normalized for G3PDH (IL-6/G3PDH ratio) was not different from baseline at 3 months but showed a significant decrease from baseline in the group treated with 0.05% CsA (p = 0.048) at 6 months. No significant between-group differences were noted and no correlation was observed between the change in IL-6/G3PDH and corneal fluorescein staining. This preliminary, small-cohort study showed a decrease in IL-6 in the conjunctival epithelium of moderate to severe dry eye patients treated with 0.05% CsA for 6 months. The observed decrease suggests that dry eye disease involves immune-mediated inflammatory processes that may be decreased by treatment with topical ophthalmic cyclosporine.

  12. [Safety and efficacy of a new preservative-free levocabastine ophthalmic solution (Levofree®) using the conjunctival provocation test].

    Science.gov (United States)

    Allaire, C; Siou-Mermet, R; Bassols, A

    2012-09-01

    To evaluate the safety and efficacy of preservative-free levocabastine 0.05 % ophthalmic solution compared to placebo (vehicle) and to preserved levocabastine 0.05 % ophthalmic suspension in the prevention of allergic conjunctivitis induced by a conjunctival provocation test. Ninety-two subjects (18-50 years) with a previous history of allergic conjunctivitis to pollen were randomised to receive either preservative-free levocabastine solution in one eye and preserved levocabastine suspension in the fellow eye (n=69), or preservative-free levocabastine in one eye and placebo in the fellow eye (n=23). One drop of each product was administered 10 minutes (visit 3) and 4 hours (visit 4) prior to the provocation test. The primary efficacy criterion was the sum of the itching and conjunctival hyperemia scores assessed at 3, 5 and 10 minutes after the provocation test. The safety evaluation included adverse events, visual acuity, intra-ocular pressure and study drug drop sensation. The efficacy of the preservative-free solution was significantly higher than that of placebo at all time points (P≤0.01) with one exception at visit 4 (3 minutes after the provocation test). It was significantly higher than that of the preserved suspension at visit 3, and equivalent at visit 4. The incidence of adverse events was lower with the preservative-free solution than with the preserved suspension. 94.2 % and 95.7 % subjects rated preservative-free levocabastine drop sensation as "good" or "very good" at visits 3 and 4 respectively, whereas these rates were 68.1 % and 63.8 % with preserved levocabastine. This difference between the two formulations was highly statistically significant (Ppreservative-free levocabastine was superior to that of the placebo and of the preserved suspension at visit 3, at least as effective as the preserved suspension at visit 4, and better tolerated at each visit. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  13. Allergic contact dermatitis from ophthalmic products: can pre-treatment with sodium lauryl sulfate increase patch test sensitivity?

    Science.gov (United States)

    Corazza, Monica; Virgili, Annarosa

    2005-05-01

    In patients suspected of allergic contact dermatitis because of topical ophthalmic medicaments, patch tests performed with patients' own products are often negative. The irritant anionic surfactant sodium lauryl sulfate (SLS) may alter the stratum corneum and increase antigen penetration. Pre-treatment of the skin with SLS 0.5% for 24 h was performed in the sites of patch tests with patients' own products in 15 selected patients. In patients previously negative to their own products tested with conventional patch tests, SLS pre-treatment showed 6 new relevant positive reactions and induced a stronger positive reaction in 1 patient. SLS pre-treatment could be proposed as an alternative promising method, which may increase sensitivity of patch tests with patients' own products.

  14. Development of irradiation support devices for production of brachytherapy seeds

    Energy Technology Data Exchange (ETDEWEB)

    Mattos, Fabio R.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos A.; Souza, Carla D.; Moura, Joao A.; Peleias Junior, Fernando S.; Karan Junior, Dib; Feher, Anselmo; Oliveira, Tiago B.; Benega, Marcos A.G., E-mail: tiagooliveira298@gmail.com, E-mail: mattos.fr@gmail.com, E-mail: elisaros@ipen.br, E-mail: czeituni@ipen.br, E-mail: carladdsouza@yahoo.com.br, E-mail: jamoura@ipen.br, E-mail: ernandopeleias@gmail.com, E-mail: s, E-mail: dib.karan@usp.br, E-mail: afeher@ipen.br, E-mail: marcosagbenega@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Ophthalmic tumors treatment with brachytherapy sources has been widely used as a primary or secondary therapy for non-malignant or malignant tumors, for example, choroid melanoma, and retinoblastoma. Ruthenium-106, Iodine-125, Palladium -103, Gold-198 and Iridium-192, are some radionuclides that can be applied for treatment of ocular tumors. These sources are in small sizes (a few millimeters) and different shapes (rods, wires, disks). To ensure high accuracy during treatment, they are positioned in eye applicators, specially designed to fit on the surface of tumor. The Nuclear and Energy Research Institute (IPEN/CNEN) in a partnership with Paulista Medicine School (UNIFESP) created a project that aims to develop a prototype of Iridium-192 seeds for treatment of eye cancer. This seed consists in a core of Ir -Pt alloy (20%-80%) with a length of 3 mm, to be activated in IPEN's IEA-R1 Reactor, and a titanium capsule sealing the core. It was imperative to develop a sustainer device for irradiation. This piece is used to avoid overlapping of one cores and, therefore, avoiding the 'shadow effect' that does not allow full activation of each core due to the high density. (author)

  15. A systematic review and meta-analysis to compare the efficacy of acyclovir 3% ophthalmic ointment to idoxuridine in curing herpetic keratitis by Day 7 of treatment.

    Science.gov (United States)

    Balderson, Diane E; Cai, Gengqian; Fries, Michael A; Kleinman, David M; McLaughlin, Megan M; Trivedi, Trupti M; Wurzelmann, John I; Young, Sheila B

    2015-04-17

    This objective of the review and analysis is to demonstrate that acyclovir (ACV) 3% ophthalmic ointment is superior to idoxuridine (IDU) in treating herpetic keratitis (HK) presenting as dendritic and geographic ulcer sub-types. Publications in human subjects were identified by searching the Ovid MEDLINE database through April 2011, combining medical subject headings (MESH) "Keratitis, Herpetic/" AND "Acyclovir/" limiting by the key words "topical" OR "ointment" and also restricted to MESH "Administration, Topical/" OR "Ointments/". The results were cross checked with the references used in the Cochrane Database Syst Rev. 1:1-134, 2009 and GlaxoSmithKline clinical documents related to acyclovir. Randomized, double-masked studies in subjects diagnosed with HK with head to head comparator arms of ACV ophthalmic ointment and topical IDU that had actual or calculable healing rates at Day seven. Data independently extracted from identified articles by two authors of this manuscript. Data from seven randomized, controlled trials (RCT) evaluating 432 subjects that met inclusion criteria (214 were treated with ACV and 218 were treated with IDU) and had Day seven healing rates calculable. All sub-classified lesions were identified as either dendritic ulcers (n = 185) or geographic ulcers (n = 35). The Cochran-Mantel-Haenszel (CMH) method in Biometrics 10:417-51, 1954 and JNCI 22:719-48, 1959, controlling for study, was performed as the primary analysis using SAS v9. Homogeneity was assessed using Breslow-Day-Tarone (BDT) test in IARC 1:1-32, 1980 and Biometrika 72:91-5, 1985. The analysis was performed with outliers removed to assess their impact. ACV showed statistically significant greater odds of healing HK at Day seven in all subjects (Odds Ratio 3.95, 95% CI2.60, 6.00, p p p = 0.0244). ACV 3% ophthalmic ointment is a valuable intervention for dendritic and geographic corneal ulcers. ACV and IDU were generally well tolerated in the studies reviewed.

  16. Pterygium: prevalence and severity in an Amazonian ophthalmic setting, Brazil

    Directory of Open Access Journals (Sweden)

    Sophie Joanna Coutts

    2012-12-01

    Full Text Available OBJECTIVE: This is a cross sectional ophthalmic clinic-based study to estimate the prevalence and severity of pterygium in a selected population in the Amazon Basin, Brazil. METHODS: The study included 225 subjects above 20 years age from three different places of residence of Manaus city (group 1, n=89, river based communities (group 2, n= 116 and indigenous rainforest inhabitants (group 3, n=20. Pterygia was graded 1-4 by torch examination and gender, age and occupation determined. RESULTS: were assessed to have pterygia (grades 2-4 117 people; 52% against 108 control subjects with bilateral disease in 43% of subjects. Prevalence of grades 2-4 increased from 36% in group 1 to 62.5 % in group 2 and 75% in group 3. Of these subjects the percentage with outdoor professions increased across the groups from 31.2% to 67.1 % and 70% respectively. Also subjects of group 2 who worked largely outdoors, showed increasing pterygia severity, from grades 2 at 57% (p=0.0002, grade 3 at 93.3% (p,0.0001 to grade 4 at 100% (p=0.0004 CONCLUSION: Amazonian communities have a high prevalence of pterygia, which correlates to greater outdoor occupation and sun exposure. This study agrees with previous worldwide reports and it is the first study to compare the prevalence of pterygium in rural and urban living in Amazonian in Brazil. This study highlights the public health significance and gross need for intervention studies.

  17. Salvage/Adjuvant Brachytherapy After Ophthalmic Artery Chemosurgery for Intraocular Retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Francis, Jasmine H., E-mail: francij1@mskcc.org [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Barker, Christopher A.; Wolden, Suzanne L.; McCormick, Beryl; Segal, Kira; Cohen, Gil [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Gobin, Y. Pierre; Marr, Brian P. [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Weill-Cornell Medical College, New York-Presbyterian Hospital, New York, New York (United States); Brodie, Scott E. [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Mount Sinai School of Medicine, New York, New York (United States); Dunkel, Ira J.; Abramson, David H. [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Weill-Cornell Medical College, New York-Presbyterian Hospital, New York, New York (United States)

    2013-11-01

    Purpose: To evaluate the efficacy and toxicity of brachytherapy after ophthalmic artery chemosurgery (OAC) for retinoblastoma. Methods and Materials: This was a single-arm, retrospective study of 15 eyes in 15 patients treated with OAC followed by brachytherapy at (blinded institution) between May 1, 2006, and December 31, 2012, with a median 19 months' follow-up from plaque insertion. Outcome measurements included patient and ocular survival, visual function, and retinal toxicity measured by electroretinogram (ERG). Results: Brachytherapy was used as adjuvant treatment in 2 eyes and as salvage therapy in 13 eyes of which 12 had localized vitreous seeding. No patients developed metastasis or died of retinoblastoma. The Kaplan-Meier estimate of ocular survival was 79.4% (95% confidence interval 48.7%-92.8%) at 18 months. Three eyes were enucleated, and an additional 6 eyes developed out-of-target volume recurrences, which were controlled with additional treatments. Patients with an ocular complication had a mean interval between last OAC and plaque of 2.5 months (SD 2.3 months), which was statistically less (P=.045) than patients without ocular complication who had a mean interval between last OAC and plaque of 6.5 months (SD 4.4 months). ERG responses from pre- versus postplaque were unchanged or improved in more than half the eyes. Conclusions: Brachytherapy following OAC is effective, even in the presence of vitreous seeding; the majority of eyes maintained stable or improved retinal function following treatment, as assessed by ERG.

  18. Salvage/Adjuvant Brachytherapy After Ophthalmic Artery Chemosurgery for Intraocular Retinoblastoma

    International Nuclear Information System (INIS)

    Francis, Jasmine H.; Barker, Christopher A.; Wolden, Suzanne L.; McCormick, Beryl; Segal, Kira; Cohen, Gil; Gobin, Y. Pierre; Marr, Brian P.; Brodie, Scott E.; Dunkel, Ira J.; Abramson, David H.

    2013-01-01

    Purpose: To evaluate the efficacy and toxicity of brachytherapy after ophthalmic artery chemosurgery (OAC) for retinoblastoma. Methods and Materials: This was a single-arm, retrospective study of 15 eyes in 15 patients treated with OAC followed by brachytherapy at (blinded institution) between May 1, 2006, and December 31, 2012, with a median 19 months' follow-up from plaque insertion. Outcome measurements included patient and ocular survival, visual function, and retinal toxicity measured by electroretinogram (ERG). Results: Brachytherapy was used as adjuvant treatment in 2 eyes and as salvage therapy in 13 eyes of which 12 had localized vitreous seeding. No patients developed metastasis or died of retinoblastoma. The Kaplan-Meier estimate of ocular survival was 79.4% (95% confidence interval 48.7%-92.8%) at 18 months. Three eyes were enucleated, and an additional 6 eyes developed out-of-target volume recurrences, which were controlled with additional treatments. Patients with an ocular complication had a mean interval between last OAC and plaque of 2.5 months (SD 2.3 months), which was statistically less (P=.045) than patients without ocular complication who had a mean interval between last OAC and plaque of 6.5 months (SD 4.4 months). ERG responses from pre- versus postplaque were unchanged or improved in more than half the eyes. Conclusions: Brachytherapy following OAC is effective, even in the presence of vitreous seeding; the majority of eyes maintained stable or improved retinal function following treatment, as assessed by ERG

  19. Stability of fortified cefazolin ophthalmic solutions prepared in artificial tears containing surfactant-based versus oxidant-based preservatives.

    Science.gov (United States)

    Rojanarata, Theerasak; Tankul, Junlathip; Woranaipinich, Chayanee; Potawanich, Paweena; Plianwong, Samarwadee; Sakulma, Sirinart; Saehuan, Choedchai

    2010-10-01

    The aim of this study was to investigate the stability of fortified cefazolin sodium ophthalmic solutions (50 mg mL⁻¹) extemporaneously prepared in commercial artificial tears containing 2 different types of preservatives, namely the surfactants and oxidants. Fortified cefazolin sodium solutions were prepared by reconstituting cefazolin for injection with sterile water and further diluted with Tears Naturale II or Natear, 2 commercial artificial tears containing polyquaternium-1 and sodium perborate, respectively, as preservatives. The solutions were then kept at room temperature (28°C) or in the refrigerator (4°C). During the 28-day period, the formulations were periodically examined for the physical appearance, pH, and the remaining drug concentrations. The antibacterial potency was evaluated as the minimal inhibitory concentration against Staphylococcus aureus strain ATCC 29923 by broth dilution technique. The activity of the preservatives was demonstrated by antimicrobial effectiveness tests. On day 28, the microbial contamination in the preparations was tested. The stability profiles of cefazolin solutions prepared in Tears Naturale II, Natear, and water were not different, but they were significantly influenced by the storage temperature. The refrigerated formulations showed no loss of drug and antibacterial potency as well as alteration of physical appearance and pH throughout the 28 days. In contrast, those kept at room temperature showed gradual change in color and odor. The degradation of drug exceeded 10% from day 3 and the decrease of antibacterial potency could be observed at week 3. All cefazolin solutions prepared in artificial tears retained the antimicrobial activity of preservatives and were free from bacterial and fungal contamination throughout the 28-day period of study. Cefazolin sodium ophthalmic solutions can be extemporaneously prepared in Tears Naturale II or Natear without the influence from different types of preservatives used in

  20. Ophthalmic, Hearing, Speaking and School Readiness Outcomes in Low Birth Weight and Normal Birth Weight Primary School Children in Mashhad-Iran

    Directory of Open Access Journals (Sweden)

    Ashraf Mohammadzadeh

    2011-01-01

    Full Text Available Low Birth weight infants are at risk of many problems. Therefore their outcome must evaluate in different ages especially in school age. In this study we determined prevalence of ophthalmic, hearing, speaking and school readiness problems in children who were born low birth weight and compared them with normal birth weight children. In a cross-sectional and retrospective study, all Primary School children referred to special educational organization center for screening before entrance to school were elected in Mashhad, Iran. In this study 2400 children enrolled to study and were checked for ophthalmic, hearing, speaking and school readiness problems by valid instrument. Data were analyzed by SPSS 11.5. This study showed that 8.3% of our population had birth weight less than 2500 gram. Visual impairment in LBW (Low Birth Weight and NBW (Normal Birth Weight was 8.29% vs. 5.74% and there was statistically significant difference between them (P=0.015. Hearing problem in LBW and NBW was 2.1% vs. 1.3 and it was not statistically significant. Speaking problem in LBW and NBW was 2.6% vs. 2.2% and it was not statistically significant. School readiness problem in LBW and NBW was 12.4% vs. 5.8% and it was statistically significant (P<0.001. According to the results, neurological problems in our society is more than other society and pay attention to this problem is critical. We believe that in our country, it is necessary to provide a program to routinely evaluate LBW children.

  1. Evaluating the efficacy of epinastine ophthalmic solution using a conjunctivitis allergen challenge model in patients with birch pollen allergic conjunctivitis.

    Science.gov (United States)

    Tagawa, Yoshiaki; Namba, Kenichi; Nakazono, Yumi; Iwata, Daiju; Ishida, Susumu

    2017-04-01

    The efficacy of epinastine 0.05% ophthalmic solution for pollen allergic conjunctivitis has already been shown in a conjunctival allergen challenge (CAC) test using cedar pollen as a challenge. The present study investigated the efficacy of this solution against birch pollen conjunctivitis in a CAC test. Ten adult subjects (eight males and two females) with asymptomatic birch pollen conjunctivitis were enrolled in this study. The average age of the subjects was 41.1 years. This study was conducted during a period without birch pollen dispersion. In each subject, the epinastine 0.05% ophthalmic solution was instilled in one eye, and an artificial tear fluid was instilled in the fellow eye in a double-blind manner. Five minutes or 4 h after the drug instillation, both eyes were challenged with an optimal concentration of birch pollen, and ocular itching and conjunctival hyperemia were then graded. Tears were collected before the drug instillation and 20 min after the pollen challenge, and the histamine level was measured. The ocular itching scores and palpebral conjunctival hyperemia scores of the epinastine-treated eyes were significantly lower than those of the contralateral control eyes when the eyes were pretreated with the drug 4 h before the CAC. There was a significant correlation between the tear histamine level and mean ocular itching score of three time points (3, 5 and 10 min) following the CAC in the control eyes but not the epinastine-treated eyes. Epinastine is effective in suppressing ocular itching and conjunctival hyperemia in birch pollen conjunctivitis. Copyright © 2017 Japanese Society of Allergology. Production and hosting by Elsevier B.V. All rights reserved.

  2. Middle Cerebral Artery, Ophthalmic Artery, and Multibranch Retinal Vessel Occlusion After Cosmetic Autologous Fat Transfer to Forehead.

    Science.gov (United States)

    Roshandel, Danial; Soheilian, Masoud; Pakravan, Mohammad; Aghayan, Sara; Peyman, Gholam A

    2015-05-01

    A 65-year-old woman with left hemiparesis and sudden loss of visual acuity in her right eye presented a few hours after cosmetic injection of autologous fat to her forehead. Right eye visual acuity was no light perception. Funduscopy revealed widespread retinal whitening and multibranch retinal vessel occlusion. Fluorescein angiography showed markedly delayed choroidal and retinal filling together with occlusion of multiple branches of retinal arteries and veins. On magnetic resonance imaging of the brain, multiple lesions compatible with recent infarction were detected. The authors diagnosed multibranch retinal artery and vein occlusion in the right ophthalmic and middle cerebral arteries due to fat emboli. This case emphasizes the need to reevaluate the safety of such aesthetic procedures, particularly in the facial zone to prevent devastating complications. Copyright 2015, SLACK Incorporated.

  3. Lifitegrast ophthalmic solution 5.0% for treatment of dry eye disease: results of the OPUS-1 phase 3 study.

    Science.gov (United States)

    Sheppard, John D; Torkildsen, Gail L; Lonsdale, John D; D'Ambrosio, Francis A; McLaurin, Eugene B; Eiferman, Richard A; Kennedy, Kathryn S; Semba, Charles P

    2014-02-01

    To assess the efficacy and safety of lifitegrast ophthalmic solution 5.0% compared with placebo in subjects with dry eye disease. Prospective, randomized, double-masked, placebo-controlled, parallel arm, multicenter clinical trial. A total of 588 adult subjects with dry eye disease. Eligible subjects were randomized 1:1 to receive topically administered lifitegrast (5.0%) or placebo (vehicle) twice daily for 84 days after a 14-day open-label placebo run-in period. After enrollment (day 0), subjects were evaluated at days 14, 42, and 84. Key objective (fluorescein and lissamine staining scores [Ora scales]) and subjective (Ocular Surface Disease Index [OSDI], 7-item visual analog scale, and ocular discomfort score [Ora scale]) measures were assessed at all visits. The primary objective efficacy measure (sign) was mean change from baseline inferior corneal staining score (ICSS) at day 84. The co-primary subjective efficacy measure (symptom) was the mean change from baseline in the visual-related function subscale score of the Ocular Surface Disease Index (VR-OSDI). Supportive measures included corneal fluorescein scores (superior, central, total region) and conjunctival lissamine scores (nasal, temporal, total region) and symptom scores at day 84. The study met the primary objective efficacy ICSS end point in demonstrating superiority of lifitegrast compared with placebo (P = 0.0007). Lifitegrast significantly reduced corneal fluorescein staining (superior, P = 0.0392; total cornea, P = 0.0148) and conjunctival lissamine staining (nasal, P = 0.0039; total conjunctiva, P = 0.0086) at day 84 versus placebo. Significant (P ophthalmic solution 5.0% significantly reduced corneal fluorescein and conjunctival lissamine staining and improved symptoms of ocular discomfort and eye dryness compared with placebo when administered twice daily over 84 days. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  4. Doplervelocimetria das artérias oftálmica e central da retina em gestantes normais Dopplervelocimetry of ophthalmic and central retinal arteries in normal pregnancies

    Directory of Open Access Journals (Sweden)

    Angélica Lemos Debs Diniz

    2005-04-01

    evaluate ophthalmic and retinal central artery Doppler indices during the second and third trimesters of normal pregnancy and to compare the right with left eye Doppler indices of normotensive women. METHODS: a cross-sectional study which evaluated central retinal and ophthalmic artery Doppler velocimetry values of 51 normal pregnant women, in the 20th to 38th week of gestation. The following values were analyzed: pulsatility and resistance indexes (PI, RI, peak systolic and end-diastolic flow velocity (PSV, EDFV and peak velocity ratio (PVR. The Doppler indices in the right and left eyes were studied by the median. The paired Student's t test was used to confront the right and left eye values and the Pearson linear correlation analysis was performed to study the value changes throughout the gestation, with the level of significance set at 5%. RESULTS: Doppler velocimetry indices of ophthalmic and central retinal arteries (median values were, respectively: PI=1.83; RI=0.78; PSV=34.20; EDFV=6.80; PVR=0.48 and PI=1.34; RI=0.70; PSV=7.40; EDFV=2.10. There was no significant difference between the right and left side Doppler values. Linear correlation analysis showed no association between the arterial values and pregnancy age. CONCLUSION: the unilateral analysis of ophthalmic and central retinal artery Doppler velocimetry values can be used in systemic maternal disease. There is no significant change in ophthalmic and central retinal artery Doppler velocimetry values throughout normal pregnancy.

  5. A comparative study of ibuprofen with paracetamol versus oxyphenbutazone with analgin combination in ophthalmic practice

    Directory of Open Access Journals (Sweden)

    Roy I

    1988-01-01

    Full Text Available A total of 200 patients of either sex with various ophthalmic inflammatory disorders of surgical and non-surgical types were treated with ibuprofen with paracetamol 1 tablet tid. or a combination of oxyphenbutazone and analgin-1 tablet t. i. d. for 7 days/ Patients in the ibuprofen with Paracetamol group recorded a signifi-cantly greater reduction in pain scores; on day 1 and 2 and in swelling scores on day 2, 5 and 7 as compared to patients receiving the combination of ox yphenbutazone and analgin. A significantly lesserr number of patients in the ibuprofen with paraeetamol group required escape analgesics. Seventy six per cent of patients in the Ibuprofen with paracetamol group were judged as showing a Very good - Good, response to treatment as against 55 per cent in the oxvphenbutazone-analgin group. It is concluded that ibuprofen with Paracetamol is superior in efficacy and a safer alternative to a combination of oxyphenbutazone and analgin.

  6. Evaluation of endothelial mucin layer thickness after phacoemulsification with next generation ophthalmic irrigating solution.

    Science.gov (United States)

    Ghate, Deepta A; Holley, Glenn; Dollinger, Harli; Bullock, Joseph P; Markwardt, Kerry; Edelhauser, Henry F

    2008-10-01

    To evaluate human corneal endothelial mucin layer thickness and ultrastructure after phacoemulsification and irrigation-aspiration with either next generation ophthalmic irrigating solution (NGOIS) or BSS PLUS. Paired human corneas were mounted in an artificial anterior chamber, exposed to 3 minutes of continuous ultrasound (US) at 80% power using the Alcon SERIES 20000 LEGACY surgical system (n = 9) or to 2 minutes of pulsed US at 50% power, 50% of the time at 20 pps using the Alcon INFINITI Vision System (n = 5), and irrigated with 250 mL of either NGOIS or BSS PLUS. A control group of paired corneas did not undergo phacoemulsification or irrigation-aspiration (n = 5). Corneas were divided and fixed for mucin staining or transmission electron microscopy. Mucin layer thickness was measured on the transmission electron microscopy prints. The mucin layer thickness in the continuous phaco group was 0.77 +/- 0.02 microm (mean +/- SE) with NGOIS and 0.51 +/- 0.01 microm with BSS PLUS (t test, P INFINITI Vision System (pulsed US) and the LEGACY surgical system (continuous US).

  7. Ophthalmic infections in children presenting to Angkor Hospital for Children, Siem Reap, Cambodia.

    Science.gov (United States)

    Khauv, Phara; Turner, Paul; Soeng, Channy; Soeng, Sona; Moore, Catrin E; Bousfield, Rachel; Stoesser, Nicole; Emary, Kate; Thanh, Duy Pham; Baker, Stephen; Hang, Vu Thi Ty; van Doorn, H Rogier; Day, Nicholas P J; Parry, Christopher M

    2014-11-05

    Ophthalmic infections cause significant morbidity in Cambodian children but aetiologic data are scarce. We investigated the causes of acute eye infections in 54 children presenting to the ophthalmology clinic at Angkor Hospital for Children, Siem Reap between March and October 2012. The median age at presentation was 3.6 years (range 6 days - 16.0 years). Forty two patients (77.8%) were classified as having an external eye infection, ten (18.5%) as ophthalmia neonatorum, and two (3.7%) as intra-ocular infection. Organisms were identified in all ophthalmia neonatorum patients and 85.7% of patients with an external eye infection. Pathogens were not detected in either of the intra-ocular infection patients. Most commonly isolated bacteria were Staphylococcus aureus (23 isolates), coagulase-negative staphylococci (13), coliforms (7), Haemophilus influenzae/parainfluenzae (6), Streptococcus pneumoniae (4), and Neisseria gonorrhoeae (2). Chlamydia trachomatis DNA was detected in 60% of swabs taken from ophthalmia neonatorum cases. This small study demonstrates the wide range of pathogens associated with common eye infections in Cambodian children. The inclusion of molecular assays improved the spectrum of detectable pathogens, most notably in neonates.

  8. The efficacy and safety of a novel posterior scleral reinforcement device in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Yongguang; Zong, Yao; Zheng, Qishan [State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou (China); Qian, Garrett [University of New South Wales (Australia); Qian, Xiaobin; Li, Yujie; Shao, Wanwen [State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou (China); Gao, Qianying, E-mail: gaoqy@mail.sysu.edu.cn [State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou (China)

    2016-05-01

    Purpose: To evaluate the efficacy and safety of posterior scleral reinforcement (PSR) device for myopia suppression in rabbits' eyes. Methods: PSR surgery was performed on the normal 12 8-week-old New Zealand white rabbits' right eyes. To determine efficacy of the device, ophthalmic examination would be taken at pre-operation and post-operation (1 week, 1 month, 3 months, 6 months, and 1 year), such as A-ultrasound, diopter and B-ultrasound. Evaluation of safety were based on the following indicators: intraocular pressure (IOP), slit lamp, fundus photography, fundus fluorescein angiography and pathological examination after surgery. The efficacy and safety of PSR device were evaluated by comparison (treated eyes and contralateral eyes) of pre and post-operation. Results: The novel PSR device could significantly shorten axial length (preoperative axial length: 16.36 ± 0.14 mm, postoperative 1 week, 1 month, 3 months, 6 months and 1 year axial lengths: 15.03 ± 0.28 mm, 15.23 ± 0.32 mm, 15.39 ± 0.31 mm, 15.45 ± 0.22 mm and 15.45 ± 0.22 mm; P = 0.00037 < 0.001) in the treated eyes (right eyes) after surgery. At different postoperative time points, the B-ultrasound images showed that the PSR located in appropriate position and supported the posterior sclera very well. At the same time, IOP of treated eyes kept a relatively stable level (preoperative IOP: 12.56 ± 2.01 mmHg, postoperative IOP: ranging from 11.33 ± 1.23 mmHg to 13.44 ± 2.19 mmHg, P > 0.05) post-operation 1 year. During observation period, there was no significant inflammatory reaction and complications such as anterior chamber flare, empyema, endophthalmitis, vitreous hemorrhage, retina detachment and retinal choroid neovascularization by slit lamp, fundus photography and fundus fluorescein angiography. In addition, there were no pathologic changes be found by comparison treated eyes group and contralateral group eyes based on pathological examinations. Conclusions: In vivo study

  9. Staff dose of hospitalization in the treatment of patients in ophthalmic brachytherapy with 125 I; Dosis al personal de hospitalizacion en el tratamiento de pacientes de braquiterapia oftalmica con I-125

    Energy Technology Data Exchange (ETDEWEB)

    Terron Leon, J. A.; Gomez Palacios, M.; Moreno Reyes, J. C.; Perales Molina, A.

    2013-07-01

    The objective of this work, therefore, has been the evaluation of the dose levels which nursing staff can receive in care for ophthalmic brachytherapy patients treated with 125 I from measurements made on the same, evaluating, in an experimental way, job security following the PR rules laid down for these treatments. (Author)

  10. [Waardenburg syndrome--ophthalmic findings and criteria for diagnosis: case reports].

    Science.gov (United States)

    Nasser, Luciano Sólia; Paranaíba, Lívia Maris Ribeiro; Frota, Ana Cláudia; Gomes, Andreia; Versiani, Gisele; Martelli Júnior, Hercílio

    2012-10-01

    To describe the clinical and imaginological features of two families with Waardenburg syndrome: type I and II, with emphasis on ophthalmic manifestations, as well as the pattern of genetic inheritance. We conducted a clinical study involving two families affected by Waardenburg syndrome, and through the pedigree, determined the present pattern of genetic inheritance. Analyses were performed including the measurement of visual acuity, the presence of dystopia cantorum (telecanthus), evaluation of iris color and retinal mapping, as well as dermatological and otological examinations. The pedigree of the family affected by the Waardenburg syndrome type I showed an autosomal dominant mode of transmission. The syndrome was present at 85.71% of patients. The dystopia cantorum was the most frequent feature, followed by the white streak on the skin of the forehead, hypopigmentation of the iris and retina and deafness. The Waardenburg syndrome family type II had 33.33% of family members affected by the syndrome. No member had dystopia cantorum and hypopigmentation of the iris. Three patients had sensorineural hearing loss (12.5%), associated with white forelock and achromatic spots confluent by the body. This study shows the importance of the ophthalmologist in aiding the diagnosis of this rare genetic condition, since it includes ocular disorders such as telecanthus, hypopigmentation of the iris and retina. The cantorum dystopia is the main diagnostic criterion to differentiate type I and II syndrome and should be done by a trained ophthalmologist. The families are in medical monitoring, receiving genetic guidelines and care related to eye protection.

  11. A STUDY ON OPHTHALMIC MANIFESTATIONS IN PITUITARY GLAND TUMOURS

    Directory of Open Access Journals (Sweden)

    Chitra Munusamy Rajendran

    2017-09-01

    Full Text Available BACKGROUND Pituitary adenoma is a benign tumour that originates from the adenohypophyseal cells of the anterior lobe of pituitary gland. It accounts for 12% to 15% of all intracranial tumours. A spectrum of ocular manifestations are seen with these tumours ranging from the absence of any visual symptoms to severe visual field defects and loss of vision. The aim of the study is to study the various ocular features and its effect on vision, visual fields and ocular motility in cases of pituitary adenoma diagnosed on CT or MRI. MATERIALS AND METHODS This is a prospective study for a period of 1 year and 8 months conducted in Regional Institute of Ophthalmology, Madras Medical College. 25 patients aged between 25 to 65 years diagnosed as pituitary adenomas on radiological imaging who presented to squint clinic were evaluated after detailed history with visual acuity, pupillary reaction, colour vision, extraocular movements, slit lamp and fundus examination. Visual field examination was done with Octopus field analyser. RESULTS In our study, 25 patients of pituitary adenoma diagnosed on radio imaging were enrolled and evaluated. Most patients were above 50 years, 15 patients of the 25 were above 50 yrs. (60%. Females were predominantly affected (76%. Visual acquity of the patient was between 6/12-6/6 (62% on presentation. Headache was the commonest mode of presentation (80%. 76% showed field defects of which bitemporal hemianopia was the commonest in 52.9%. Pituitary macroadenoma 96% was the commonest type. Optic atrophy was seen only in 4 cases. Others had normal fundus. CONCLUSION Neuro-ophthalmic evaluation plays a major role not only in early detection, planning of treatment and further follow up, but also prevents visual loss if intervened early.

  12. 76 FR 51876 - Medical Devices; Ophthalmic Devices; Classification of the Eyelid Thermal Pulsation System

    Science.gov (United States)

    2011-08-19

    ... of exposure to non- ionizing radiation; (2) Design, description, and performance data should validate.../testing should validate electromagnetic compatibility (EMC) and safety of exposure to non-ionizing.... Malfunction Non-clinical and Clinical Performance Testing. User error Labeling. FDA believes that the...

  13. Ophthalmic manifestations of vitamin A and D deficiency in two autistic teenagers: case reports and a review of the literature.

    LENUS (Irish Health Repository)

    Duignan, Emma

    2015-01-01

    We describe the cases of 2 autistic children with ophthalmic and systemic manifestations of vitamin A deficiency due to food faddism. Although vitamin A deficiency is common in the developing world, reports in developed societies are rare. Our patients presented over a 1-year period. The patients were 14 and 13 years old at the time of presentation and were both found to have marked features of vitamin A deficiency related to unusual dietary habits. Anterior segment signs of xerophthalmia were present in both patients. In addition, patient 1 showed evidence of a rod-predominant retinopathy, which resolved with vitamin A supplementation. Due to its rare occurrence, hypovitaminosis A must be highlighted and anticipated in this cohort.

  14. Evaluation of the ophthalmic and dermal irritability of the OLEOMASAJE formulation

    Directory of Open Access Journals (Sweden)

    Maritza F. Díaz

    2015-08-01

    Full Text Available Context: Ozonized vegetable oils present germicidal effects which can be used as active principle in different cosmetological compositions. The thematic about of the corporal massage advantage have been very treatment by aesthetics, dermatologic and consumers. OLEOMASAJE formulation content ozonized sunflower oil OLEOZON as active principle active which present moisturizer and conditioner effects. Aims: To determine the possible dermal and ophthalmic irritability effects of the OLEOMASAJE. Methods: The trial was conducted in rabbits and the techniques described in the standardized procedures of the work established by the Center of Biological Research and Evaluations from Pharmacy and Food Institute of Havana University were used according to Norma ISO 10993-10. The ethical principles of the Good Practices of Laboratory were fulfilled to avoid suffering to the animals during the experimentation. Male rabbits with body weight between 2.05 and 2.48 kg were used. In the skin and the ocular structures the effects were observed immediately after of the application at 1, 24, 48 and 72 hours. Draize´s scale was applied to evaluate skin and ocular structures lesions. Results: The OLEOMASAJE formulation does not irritate de skin of the assayed rabbits. However, the ocular structures irritability index was of 4.5 after of first hour to apply of product. These wounds were missing before of 24 hours to apply of product. Conclusions: The OLEOMASAJE formulation obeys the indispensable requirements for the acceptance as cosmetic product and for it is used in corporal massage.

  15. Comparison of corneal power, astigmatism, and wavefront aberration measurements obtained by a point-source color light-emitting diode-based topographer, a Placido-disk topographer, and a combined Placido and dual Scheimpflug device.

    Science.gov (United States)

    Ventura, Bruna V; Wang, Li; Ali, Shazia F; Koch, Douglas D; Weikert, Mitchell P

    2015-08-01

    To evaluate and compare the performance of a point-source color light-emitting diode (LED)-based topographer (color-LED) in measuring anterior corneal power and aberrations with that of a Placido-disk topographer and a combined Placido and dual Scheimpflug device. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas USA. Retrospective observational case series. Normal eyes and post-refractive-surgery eyes were consecutively measured using color-LED, Placido, and dual-Scheimpflug devices. The main outcome measures were anterior corneal power, astigmatism, and higher-order aberrations (HOAs) (6.0 mm pupil), which were compared using the t test. There were no statistically significant differences in corneal power measurements in normal and post-refractive surgery eyes and in astigmatism magnitude in post-refractive surgery eyes between the color-LED device and Placido or dual Scheimpflug devices (all P > .05). In normal eyes, there were no statistically significant differences in 3rd-order coma and 4th-order spherical aberration between the color-LED and Placido devices and in HOA root mean square, 3rd-order coma, 3rd-order trefoil, 4th-order spherical aberration, and 4th-order secondary astigmatism between the color-LED and dual Scheimpflug devices (all P > .05). In post-refractive surgery eyes, the color-LED device agreed with the Placido and dual-Scheimpflug devices regarding 3rd-order coma and 4th-order spherical aberration (all P > .05). In normal and post-refractive surgery eyes, all 3 devices were comparable with respect to corneal power. The agreement in corneal aberrations varied. Drs. Wang, Koch, and Weikert are consultants to Ziemer Ophthalmic Systems AG. Dr. Koch is a consultant to Abbott Medical Optics, Inc., Alcon Surgical, Inc., and i-Optics Corp. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Cross-linked chitosan-dextran sulphate vehicle system for controlled release of ciprofloxaxin drug: An ophthalmic application

    Directory of Open Access Journals (Sweden)

    Chetan Chavan

    2017-01-01

    Full Text Available The major challenge associated with conventional eye-drop is the rapid drug loss due to precorneal defence barrier. In this context, controlled-release system of ciprofloxacin-conjugated chitosan (CS-Dextran sulphate (DS nanoparticles (NPs have been synthesized, to increase the bioavailability. The formulated drug delivery vehicle was evaluated for its therapeutic value in the simulated tear fluidat pH 7.4. Ophthalmic microbes were tested with this formulation, to confirm the drug efficacy; which showed conducive therapeutic values of both MIC and MBC. Ocular irritancy test was performed using HET-CAM test, which showed that the CS-DS system did not yield any vascular response, offering it to be a non-irritant to the ocular surface. The release studies showed monotonous controlled-release for duration of 21 h. A fine cross-linking between CS and DS has been demonstrated to form CS-DS NPs and their interaction with drug has been evaluated using conventional characterization tools.

  17. A traumatic dural arteriovenous fistula between the inferolateral trunk of the internal carotid artery and the ophthalmic vein: A case of transvenous coil embolization via the facial vein

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Young; Hong, Chang Ki; Suh, Sang Hyun [Dept. of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Dong Ik [Dept. of of Radiology, CHA Bundang Medical Center, CHA University, Seongnam (Korea, Republic of)

    2017-05-15

    A 31-year-old man was admitted with exophthalmos. He suffered from progressive exophthalmos, bruit and conjunctival chemosis 7 days after head trauma caused by falling down. Cerebral angiography showed a dural arteriovenous fistula (DAVF) draining into the ophthalmic vein caused by tear in the inferolateral trunk, which is a rare presentation of traumatic DAVF. Selective transvenous coil embolization was performed via the facial vein without neurologic complications.

  18. Simulated Leaching (Migration) Study for a Model Container-Closure System Applicable to Parenteral and Ophthalmic Drug Products.

    Science.gov (United States)

    Jenke, Dennis; Egert, Thomas; Hendricker, Alan; Castner, James; Feinberg, Tom; Houston, Christopher; Hunt, Desmond G; Lynch, Michael; Nicholas, Kumudini; Norwood, Daniel L; Paskiet, Diane; Ruberto, Michael; Smith, Edward J; Holcomb, Frank; Markovic, Ingrid

    2017-01-01

    A simulating leaching (migration) study was performed on a model container-closure system relevant to parenteral and ophthalmic drug products. This container-closure system consisted of a linear low-density polyethylene bottle (primary container), a polypropylene cap and an elastomeric cap liner (closure), an adhesive label (labeling), and a foil overpouch (secondary container). The bottles were filled with simulating solvents (aqueous salt/acid mixture at pH 2.5, aqueous buffer at pH 9.5, and 1/1 v/v isopropanol/water), a label was affixed to the filled and capped bottles, the filled bottles were placed into the foil overpouch, and the filled and pouched units were stored either upright or inverted for up to 6 months at 40 °C. After storage, the leaching solutions were tested for leached substances using multiple complementary analytical techniques to address volatile, semi-volatile, and non-volatile organic and inorganic extractables as potential leachables.The leaching data generated supported several conclusions, including that (1) the extractables (leachables) profile revealed by a simulating leaching study can qualitatively be correlated with compositional information for materials of construction, (2) the chemical nature of both the extracting medium and the individual extractables (leachables) can markedly affect the resulting profile, and (3) while direct contact between a drug product and a system's material of construction may exacerbate the leaching of substances from that material by the drug product, direct contact is not a prerequisite for migration and leaching to occur. LAY ABSTRACT: The migration of container-related extractables from a model pharmaceutical container-closure system and into simulated drug product solutions was studied, focusing on circumstances relevant to parenteral and ophthalmic drug products. The model system was constructed specifically to address the migration of extractables from labels applied to the outside of the

  19. Study and development of an Iridium-192 seed for use in ophthalmic cancer; Estudo e desenvolvimento de uma semente de iridio-192 para aplicacao em cancer oftalmico

    Energy Technology Data Exchange (ETDEWEB)

    Mattos, Fabio Rodrigues de

    2013-07-01

    Even ocular tumors are not among the cases with a higher incidence, they affect the population, especially children. The Institute of Energy and Nuclear Research (IPEN-CNEN/SP) in partnership with Escola Paulista de Medicina (UNIFESP), created a project to develop and implement a alternative treatment for ophthalmic cancer that use brachytherapy iridium-192 seeds. The project arose by reason of the Escola Paulista treat many cancer cases within the Unified Health System (SUS) and the research experience of sealed radioactive sources group at IPEN. The methodology was developed from the available infrastructure and the experience of researchers. The prototype seed presents with a core (192-iridium alloy of iridium-platinum) of 3.0 mm long sealed by a capsule of titanium of 0.8 mm outside diameter, 0.05 mm wall thickness and 4,5mm long. This work aims to study and develop a seed of iridium-192 from a platinum-iridium alloy. No study on the fabrication of these seeds was found in available literature. It was created a methodology that involved: characterization of the material used in the core, creation of device for neutron activation irradiation and and seed sealing tests. As a result, proved the feasibility of the method. As a suggestion for future work, studies regarding metrology and dosimetry of these sources and improvement of the methodology should be carried out, for future implementation in national scope. (author)

  20. Evaluation of web-based annotation of ophthalmic images for multicentric clinical trials.

    Science.gov (United States)

    Chalam, K V; Jain, P; Shah, V A; Shah, Gaurav Y

    2006-06-01

    An Internet browser-based annotation system can be used to identify and describe features in digitalized retinal images, in multicentric clinical trials, in real time. In this web-based annotation system, the user employs a mouse to draw and create annotations on a transparent layer, that encapsulates the observations and interpretations of a specific image. Multiple annotation layers may be overlaid on a single image. These layers may correspond to annotations by different users on the same image or annotations of a temporal sequence of images of a disease process, over a period of time. In addition, geometrical properties of annotated figures may be computed and measured. The annotations are stored in a central repository database on a server, which can be retrieved by multiple users in real time. This system facilitates objective evaluation of digital images and comparison of double-blind readings of digital photographs, with an identifiable audit trail. Annotation of ophthalmic images allowed clinically feasible and useful interpretation to track properties of an area of fundus pathology. This provided an objective method to monitor properties of pathologies over time, an essential component of multicentric clinical trials. The annotation system also allowed users to view stereoscopic images that are stereo pairs. This web-based annotation system is useful and valuable in monitoring patient care, in multicentric clinical trials, telemedicine, teaching and routine clinical settings.

  1. Azithromycin 1.5% ophthalmic solution: efficacy and treatment modalities in chronic blepharitis

    Directory of Open Access Journals (Sweden)

    Ali Fadlallah

    2012-06-01

    Full Text Available PURPOSE: To assess the efficacy of topical 1.5% azithromycin in the treatment of moderate to severe chronic blepharitis and to compare the efficacy of two different treatment modalities. METHODS: A randomized clinical trial included 67 patients with chronic anterior and/or posterior blepharitis, followed-up for 3 months. Signs and symptoms were graded according to severity. Patients were randomized into two groups: 33 patients in group I and 34 patients in group II. Group I patients were treated with topical 1.5% azithromycin twice a day for three days, and Group II patients were treated with topical 1.5% azithromycin twice a day for three days then at bedtime for the rest of the month. All patients were instructed to apply warm compresses and an eye-friendly soap twice daily. RESULTS: Patients in both groups tolerated the treatment with minimal irritation. A significant improvement in signs and symptoms was noted at the one week follow-up visit. Group II showed a more pronounced and longer-lasting improvement that persisted after three months of follow-up. CONCLUSION: Topical 1.5% azithromycin ophthalmic solution is an effective treatment option for chronic blepharitis. In moderate to severe blepharitis, a one month treatment is safe and shows better improvement than the three-day protocol with no significant relapse until three months of follow-up.

  2. Ophthalmic manifestations of 107 cases with hemolysis, elevated liver enzymes and low platelet count syndrome

    International Nuclear Information System (INIS)

    Erbagci, I.; Okumus, S.; Bekir, Necdet A.; Karaca, M.; Ugur, Mete G.

    2008-01-01

    Objective was to present various ophthalmologic disorders in a clinical series of hemolysis, elevated liver enzymes and low platelet count (HELLP) syndrome cases. This is a prospective clinical study performed between 2002 and 2005. One hundred seven HELLP attended in either Departments of Ophthalmology or Obstetrics and Gynecology, Medical School, Gaziantep University, Gaziantep, Turkey were evaluated. Mean age was 25.5 (22-36 years). Mean levels were 2.5 gravidity, 1.3 parity, 55,200/mm3 platelet counts, 308.7 U/I aspartate transaminase, 255.4 U/I alanine transminase and 1711.6U/I lactate dehydrogenase. Four patients died (3.7%) despite the proper treatments. Cortical blindness was observed in 3 cases (2.7%), serous retinal detachments in 4 (3.7%) and mild hypertension changes in 18 (16%). Ophthalmic complications are possible during and after this syndrome. Almost all ophthalmologic changes recover after delivery by cesarean section, nevertheless, it is essential that ophthalmologists should be aware of retinal disorders when this fatal complication of pregnancy is encountered. (author)

  3. [Use of a novel polymer, the in-situ gelling mucoadhesive thiolated poly(aspartic acid) in ophthalmic drug delivery].

    Science.gov (United States)

    Horvát, Gabriella; Budai-Szűcs, Mária; Berkó, Szilvia; Szabóné-Révész, Piroska; Gyarmati, Benjámin; Szilágyi, Barnabas Áron; Szilágyi, András; Csányi Erzsébet

    2015-01-01

    The bioavailability of drugs used on mucosal surfaces can be increased by the use of mucoadhesive polymers. A new type of mucoadhesive polymers is the group of thiolated polymers with thiol group containing side chains. These polymers are able to form covalent bonds (disulphide linkages) with the mucin glycoproteins. For the formulation of an ocular drug delivery system (DDS) thiolated poly(aspartic acid) polymer (ThioPASP) was used. Our aim was to determine their biocompatibility, mucoadhesion and drug release property. According to the results it can be established that the thiolated poly(aspartic acid) polymers can be a potential vehicle of an ocular drug delivery system due to their biocompatibility, good mucoadhesive property and drug release profile. Thanks to their properties controlled drug delivery can be achieved and bioavailability of the ophthalmic formulation can be increased, while the usage frequency can be decreased.

  4. Patient flow improvement for an ophthalmic specialist outpatient clinic with aid of discrete event simulation and design of experiment.

    Science.gov (United States)

    Pan, Chong; Zhang, Dali; Kon, Audrey Wan Mei; Wai, Charity Sue Lea; Ang, Woo Boon

    2015-06-01

    Continuous improvement in process efficiency for specialist outpatient clinic (SOC) systems is increasingly being demanded due to the growth of the patient population in Singapore. In this paper, we propose a discrete event simulation (DES) model to represent the patient and information flow in an ophthalmic SOC system in the Singapore National Eye Centre (SNEC). Different improvement strategies to reduce the turnaround time for patients in the SOC were proposed and evaluated with the aid of the DES model and the Design of Experiment (DOE). Two strategies for better patient appointment scheduling and one strategy for dilation-free examination are estimated to have a significant impact on turnaround time for patients. One of the improvement strategies has been implemented in the actual SOC system in the SNEC with promising improvement reported.

  5. How to handle and care for bulbs in ophthalmic equipment

    Directory of Open Access Journals (Sweden)

    Ismael Cordero

    2013-08-01

    Full Text Available Many devices used in eye care rely on light bulbs or lamps for their operation. All light bulbs have a limited lifespan and when the bulb fails the device becomes unusable. Therefore, knowing how to handle, how to inspect and how to replace bulbs is important. Just as important is keeping spare bulbs to hand!

  6. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  7. Sympathetic ophthalmitis following vitreoretinal surgery: Does antecedent trauma make a difference?

    Directory of Open Access Journals (Sweden)

    Ekta Rishi

    2015-01-01

    Full Text Available Background: Sympathetic ophthalmitis (SO has been reported following vitrectomy; however, there is a lack of data on the role of antecedent penetrating ocular trauma impacting the disease manifestation in eyes developing SO following vitrectomy. Aim: To report differences in the presentation and outcomes of SO in eyes with or without a history of antecedent penetrating trauma; SO being diagnosed after vitreoretinal (VR surgery. Design: Comparative case series. Methods: Seventeen consecutive patients presenting with SO following VR surgery, diagnosed between 1995 and 2011 were included. Eyes with and without prior penetrating injury were included in Group I (n = 7 and Group II (n = 10, respectively. All Group I patients had received systemic steroids prior to presentation. Demographic and clinical parameters were evaluated. Results: Differences were observed between Group I and Group II mainly with regards to time interval between VR surgery and diagnosis of SO (1.5 months vs. 8 months, P = 0.10, presence of neurosensory detachments (100% vs. 30%, P = 0.01, and the inciting eye vision at presentation (nil light perception in 28.5% vs. 80%, P = 0.049. Other differences observed though not statistically significant were optic disc and retinal vessel involvement (42% vs. 70%, P = 0.28, Dalen-Fuchs nodules (localized vs. diffuse and leaks on fundus fluorescein angiography (pin-head vs. pin-point leak. Conclusion: SO in patients with antecedent penetrating ocular trauma present early with the central serous chorioretinopathy-like picture. Prior use of systemic steroids might have a bearing on the differences in presentation and the visual acuities between the two groups.

  8. Investigation of the imaging diagnosis on the ophthalmic orbital diseases

    International Nuclear Information System (INIS)

    Yoshizawa, Toshikazu

    1991-01-01

    Ultrasonographic examination, X-ray computerized tomography (CT) and magnetic resonance imaging (MRI) were performed on orbital diseases. Ultrasonographic examination was a simple, rapid and harmless noninvasive precedure as a diagnostic tool for evaluation of soft tissues. Echography was not more precise than X-ray CT and MRI scan in orbital diagnosis of the localization, size and well-defined outline of the lesion, relating to the peri- and retroorbital organs, however, was useful for screening study of an orbital lesion. B-mode of orbital tumors was effective for the ultrasonic diagnosis and classification according to four types; solid, cystic, angiomatous and infiltrative patterns. B-scan study of intraorbital inflammatory pseudo tumor could provide a differential diagnosis between inflammatory edema and an inflammatory mass lesion. Echographic pictures of dural arterio-venous fistula disclosed the vascular dilatation of superior ophthalmic vein and those of Basedow's disease with thickening of extraocular muscles. X-ray CT revealed intraorbital and intraocular disease, the globes and its immediate surrounding tissue (optic nerve, extraocular muscle, etc.) and bony orbital walls as the same slice of film. X-ray CT pictures of a coronal section, the contrast enhancement, calcification and destruction of the bone were helpful for diagnosis. However, the displays of disorders near the bone were ill-defined because of an artifact induced by high X-ray absorptive power of the bone. MRI was an equipment for superior contrast resolution, with provided a tomography of any section, without artifacts of the bone, and was the superior technique for displaying a vascular lesion. MRI of orbital disease was effective for reconstructing the spatial correlations between the lesion and its surounding tissues. MRI, however, provided no information of the skeleton, being not available for subjects with a magnetic substance. (author)

  9. Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery

    Directory of Open Access Journals (Sweden)

    Inoue Y

    2016-12-01

    Full Text Available Yasushi Inoue, Shintarou Ochi Inoue Eye Clinic, Tamano, Okayama, Japan Purpose: To evaluate the effects of diquafosol sodium ophthalmic solution 3% (DQS and artificial tears (AT on higher-order aberrations (HOAs in patients with dry eye after cataract surgery. Design: This was a post hoc analysis of a previously conducted randomized clinical study. Methods: Fifty-nine eyes from 42 patients (17 males and 25 females, aged 72.6±8.0 years with verified or suspected dry eye at 4 weeks after cataract surgery were evaluated. The dry eye patients were randomly assigned to receive DQS or AT for 4 weeks. Tear breakup time (BUT, corneal and conjunctival fluorescein staining scores, and HOAs were analyzed before and after instillation. HOAs were measured consecutively for 10 seconds with a wavefront analyzer. Average HOAs, HOA fluctuations (fluctuation index [FI] and changes in HOAs (stability index [SI] were compared within and between the two groups. Results: After 4 weeks of instillation, BUT significantly increased (P=0.001 compared with preinstillation values in the DQS group, but not in the AT group. This increase in BUT in the DQS group was significantly greater than in the AT group (P=0.014. Corneal and conjunctival fluorescein staining scores after instillation significantly improved compared with preinstillation values in the DQS group (P=0.018. In HOAs, the cornea aberration changed from an upward curve (a sawtooth pattern to an almost constant value (a stable pattern in the DQS group, but not in the AT group. In FI and SI, there were no significant changes in either group; however, FI and SI were significantly lower in the DQS group than in the AT group (both, P=0.004. Conclusion: The dry eye patients after cataract surgery had a visual dysfunction in HOAs. DQS is effective to treat dry eye disease after cataract surgery with improvement of visual function. Keywords: cataract surgery, dry eye, tear film breakup time, higher-order aberrations

  10. Bromfenac ophthalmic solution 0.09 %: human aqueous humor concentration detected by high-performance liquid chromatography.

    Science.gov (United States)

    Macrì, Angelo; Vagge, Aldo; Salis, Annalisa; Fucile, Carmen; Marini, Valeria; Martelli, Antonietta; Giuffrida, Sebastiano; Iester, Michele; Damonte, Gianluca; Mattioli, Francesca

    2017-04-01

    The purpose of this study was to evaluate the aqueous humor concentrations of bromfenac ophthalmic solution 0.09 % in patients undergoing phacoemulsification. Patients requiring cataract extraction received one drop (50 µL) of bromfenac 0.09 % solution in the eye to be operated, before bedtime the day before surgery or the morning of the surgery. The last administration was recorded. At the time of paracentesis, an aqueous humor sample was collected with a 30-gauge needle attached to a TB syringe and was later analyzed by high-performance liquid chromatography for drug concentration. 188 treated volunteers and 48 control, untreated, subjects were included in the study. The mean aqueous concentration of bromfenac in the treated group was 37.60 ± 68.86 and 0 nM (nmol/L) in the control group (p < 0.0001). Correlation coefficient in bromfenac group between time elapsed from instillation and drug concentration was -0.16 (p not significant). Bromfenac showed properties of good penetration and stable concentration in aqueous humor up to about 12 h after instillation.

  11. Direct-puncture approach to the extraconal portion of the superior ophthalmic vein for carotid cavernous fistulae

    International Nuclear Information System (INIS)

    Kurata, A.; Suzuki, S.; Iwamoto, K.; Miyazaki, T.; Inukai, M.; Abe, K.; Niki, J.; Yamada, M.; Fujii, K.; Kan, S.

    2009-01-01

    The transvenous approach via the superior ophthalmic vein (SOV) is an available approach for carotid cavernous fistula (CCF), especially in the event that there is no other suitable approach route to the fistula. Surgical exposure of the peripheral roots of the SOV is commonly used; however, often, the SOV is often not accessible because of anatomical problems and/or complications. In this paper, we present and discuss our original direct-puncture approach to the extraconal portion of the SOV. An attempt on three patients with traumatic CCF failed with the transarterial approach and the conventional venous approach via the inferior petrosal sinus; therefore, the patients were treated with the direct-puncture approach to the extraconal portion of the SOV using two-dimensional digital subtraction angiography with local anesthesia. All cases that had tortuous and partially stenotic division of the SOV were treated successfully with this approach and without complications. This approach will become an alternate approach, especially when the peripheral roots of the SOV are focally narrowed and tortuous, making it impossible to insert a catheter. (orig.)

  12. 78 FR 46977 - Ophthalmic Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-08-02

    ... intraoperative management of clear corneal incisions with a wound leak demonstrated by Seidel test, and for... a disability, please contact AnnMarie Williams at Annmarie.Williams@fda.hhs.gov or 301-796-5966, at...

  13. 77 FR 42503 - Ophthalmic Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2012-07-19

    ... committee meeting cannot always be published quickly enough to provide timely notice. Therefore, you should... perception, the retina must be able to respond to electrical stimulation as evidenced by an electrically...

  14. Device-Centric Monitoring for Mobile Device Management

    Directory of Open Access Journals (Sweden)

    Luke Chircop

    2016-03-01

    Full Text Available The ubiquity of computing devices has led to an increased need to ensure not only that the applications deployed on them are correct with respect to their specifications, but also that the devices are used in an appropriate manner, especially in situations where the device is provided by a party other than the actual user. Much work which has been done on runtime verification for mobile devices and operating systems is mostly application-centric, resulting in global, device-centric properties (e.g. the user may not send more than 100 messages per day across all applications being difficult or impossible to verify. In this paper we present a device-centric approach to runtime verify the device behaviour against a device policy with the different applications acting as independent components contributing to the overall behaviour of the device. We also present an implementation for Android devices, and evaluate it on a number of device-centric policies, reporting the empirical results obtained.

  15. Increasing efficacy and reducing systemic absorption of brimonidine tartrate ophthalmic gels in rabbits.

    Science.gov (United States)

    Pang, Xiaochen; Li, Jiawei; Pi, Jiaxin; Qi, Dongli; Guo, Pan; Li, Nan; Wu, Yumei; Liu, Zhidong

    2018-03-01

    Systemic absorption of ocularly administered Brimonidine Tartrate has been reported to give rise to several side-effects. Hence, it has become crucial to develop a delivery system that could increase efficacy and reduce systemic absorption. Therefore, the present work aims to develop Brimonidine Tartrate gels with different concentrations (0.05%, 0.1%, and 0.2% w/v, respectively) using Carbopol 974 P and HPMC E4M, and compare the therapeutic efficacy and systemic absorption with that of eye drop (0.2%, w/v) by UPLC-MS/MS. The result of histological analysis did not show any morphological or structural changes after the administration of formulations. In vitro residence time studies demonstrated that the gels exhibited a better precorneal residence time as compared with the eye drop. The gels with lower concentrations of the drug (0.05% and 0.1%, w/v) could significantly decrease intraocular pressure (IOP) in both normal and water-loaded rabbits as compared to the eye drop. Finally, the values of the ratio of AUC (0→∞) in comparison to eye drop showed the gels with lower concentrations of Brimonidine Tartrate could decrease the systemic absorption. From the result, it can be concluded the 0.1% ophthalmic gel has a potential to improve therapeutic efficacy and reduce the potential toxicity caused by systemic absorption.

  16. Evaluation of alcaftadine 0.25% ophthalmic solution in acute allergic conjunctivitis at 15 minutes and 16 hours after instillation versus placebo and olopatadine 0.1%

    Directory of Open Access Journals (Sweden)

    Jack V Greiner

    2011-01-01

    Full Text Available Jack V Greiner1,2, Kimberly Edwards-Swanson3, Avner Ingerman41Schepens Eye Research Institute, Boston, MA; 2Department of Ophthalmology, Harvard Medical School, Boston, MA; 3Johnson & Johnson Consumer and Personal Products Worldwide, Skillman, NJ; 4Ora Inc, Andover, MA, USAPurpose: To evaluate the effectiveness of alcaftadine 0.05%, 0.1%, and 0.25% ophthalmic solutions in treating the signs and symptoms of allergic conjunctivitis when compared with olopatadine hydrochloride 0.1% and placebo using the conjunctival allergen challenge (CAC model.Methods: One hundred and seventy subjects were randomized and 164 subjects completed all visits. CAC was performed to determine and confirm subjects’ eligibility at visits 1 and 2, respectively. The CAC was repeated at visit 3 (day 0 ± 3, 16 hours after study medication instillation, and at visit 4 (day 14 ± 3, 15 minutes after instillation. Ocular itching and conjunctival redness were evaluated after an allergen challenge, along with several secondary endpoints.Results: Alcaftadine 0.25% and olopatadine 0.1% treatments exhibited significantly lower mean scores compared with placebo for ocular itching and conjunctival redness at visits 3 and 4. Most adverse events were self-limiting and mild in severity. No serious treatment-related adverse events occurred.Conclusion: Treatment with alcaftadine 0.25% ophthalmic solution resulted in mean differences of >1 unit (ocular itching and approximately >1 unit (conjunctival redness, which was significant (P < 0.001 compared with placebo treatment. All doses of alcaftadine were safe and well tolerated in the population studied.Keywords: alcaftadine, allergic conjunctivitis, conjunctival allergen challenge

  17. Stability-Indicating HPTLC Method for Simultaneous Estimation of Flurbiprofen and Chloramphenicol in Ophthalmic Solution.

    Science.gov (United States)

    Sadakwala, Vaishnavi M; Chauhan, Renu S; Shah, Shailesh A; Shah, Dinesh R

    2016-01-01

    A specific, accurate and reproducible stability-indicating high performance thin layer chromatography (HPTLC) method was developed for the estimation of flurbiprofen and chloramphenicol in the presence of their degradation products. Degradation studies of both the drugs were carried out in acidic, alkaline, neutral, oxidative, photolytic and thermal stress conditions. Separation was performed on thin layer chromatography plate precoated with silica gel 60 F254 using ethyl acetate : n-hexane : methanol : tri-ethyl amine (5 : 4 : 2 : 0.5, v/v/v/v). Spots at retention factor 0.29 and 0.62 were recognized as flurbiprofen and chloramphenicol, respectively, and were quantified through densitometric measurements at wavelength 267 nm. Method was found to be linear over the concentration range 12-60 ng/spot with correlation coefficient of 0.9997 for flurbiprofen and 200-1,000 ng/spot with correlation coefficient of 0.9977 for chloramphenicol. The proposed method was applied to the estimation of flurbiprofen and chloramphenicol in commercial ophthalmic formulation. The developed HPTLC method can be applied for routine analysis of flurbiprofen and chloramphenicol in the presence of their degradation products in their individual as well as combined pharmaceutical formulations. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Power source device for thermonuclear device

    International Nuclear Information System (INIS)

    Ozaki, Akira.

    1992-01-01

    The present invention provides a small sized and economical power source device for a thermonuclear device. That is, the device comprises a conversion device having a rated power determined by a power required during a plasma current excitation period and a conversion device having a rated power determined by a power required during a plasma current maintaining period, connected in series to each other. Then, for the former conversion device, power is supplied from an electric power generator and, for the latter, power is supplied from a power system. With such a constitution, during the plasma electric current maintaining period for substantially continuous operation, it is possible to conduct bypassing paired operation for the former conversion device while the electric power generator is put under no load. Further, since a short period rated power may be suffice for the former conversion device and the electric power generator having the great rated power required for the plasma electric current excitation period, they can be reduced in the size and made economical. On the other hand, since the power required for the plasma current maintaining period is relatively small, the capacity of the continuous rated conversion device may be small, and the power can be received from the power system. (I.S.)

  19. Stability-Indicating HPLC Method for Simultaneous Determination of Chloramphenicol, Dexamethasone Sodium Phosphate and Tetrahydrozoline Hydrochloride in Ophthalmic Solution.

    Science.gov (United States)

    AlAani, Hashem; Alnukkary, Yasmin

    2016-03-01

    A simple stability-indicating RP-HPLC assay method was developed and validated for quantitative determination of Chloramphenicol, Dexamethasone Sodium Phosphate and Tetrahydrozoline Hydrochloride in ophthalmic solution in the presence of 2-amino-1-(4-nitrophenyl)propane-1,3-diol, a degradation product of Chloramphenicol, and Dexamethasone, a degradation product of Dexamethasone Sodium Phosphate. Effective chromatographic separation was achieved using C18 column (250 mm, 4.6 mm i.d., 5 μm) with isocratic mobile phase consisting of acetonitrile - phosphate buffer (pH 4.0; 0.05 M) (30:70, v/v) at a flow rate of 1 mL/minute. The column temperature was maintained at 40°C and the detection wavelength was 230 nm. The proposed HPLC procedure was statistically validated according to the ICH guideline, and was proved to be stability-indicating by resolution of the APIs from their forced degradation products. The developed method is suitable for the routine analysis as well as stability studies.

  20. Trigeminofacial reflex: a means of detecting proximity to ophthalmic and maxillary divisions of the trigeminal nerve during surgery.

    Science.gov (United States)

    AlMasri, Omar A; Brown, Emma E; Forster, Alan; Kamel, Mahmoud H

    2014-11-01

    The aim in this paper was to localize and detect incipient damage to the ophthalmic and maxillary branches of the trigeminal nerve during tumor surgery. This was an observational study of patients with skull base, retroorbital, or cavernous sinus tumors warranting dissection toward the cavernous sinus at a university hospital. Stimuli were applied as normal during approach to the cavernous sinus to localize cranial nerves (CNs) III, IV, and VI. Recordings were also obtained from the facial muscles to localize CN VII. The trigeminofacial reflex was sought simply by observing a longer time base routinely. Clear facial electromyography responses were reproduced when stimuli were applied to the region of V1, V2, and V3. Response latency was increased compared with direct CN VII stimuli seen in some cases. Responses gave early warning of approach to these sensory trigeminal branches. The authors submit this as a new technique, which may improve the chances of preserving trigeminal sensory branches during surgery in this region.

  1. Mounting of Biomaterials for Use in Ophthalmic Cell Therapies.

    Science.gov (United States)

    Harkin, Damien G; Dunphy, Siobhan E; Shadforth, Audra M A; Dawson, Rebecca A; Walshe, Jennifer; Zakaria, Nadia

    2017-11-01

    When used as scaffolds for cell therapies, biomaterials often present basic handling and logistical problems for scientists and surgeons alike. The quest for an appropriate mounting device for biomaterials is therefore a significant and common problem. In this review, we provide a detailed overview of the factors to consider when choosing an appropriate mounting device including those experienced during cell culture, quality assurance, and surgery. By way of example, we draw upon our combined experience in developing epithelial cell therapies for the treatment of eye diseases. We discuss commercially available options for achieving required goals and provide a detailed analysis of 4 experimental designs developed within our respective laboratories in Australia, the United Kingdom, and Belgium.

  2. Neurofibromatosis: an update of ophthalmic characteristics and applications of optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Abdolrahimzadeh B

    2016-05-01

    Full Text Available Barmak Abdolrahimzadeh,1 Domenica Carmen Piraino,2 Giorgio Albanese,2 Filippo Cruciani,2 Siavash Rahimi3 1Polimed Beltramelli Medical Center, Rome, Italy; 2Section of Ophthalmology, Department of Sense Organs, University of Rome “Sapienza”, Rome, Italy; 3Pathology Centre, Queen Alexandra Hospital, Portsmouth, UK Abstract: Neurofibromatosis (NF is a multisystem disorder and tumor predisposition syndrome caused by genetic mutation on chromosome 17-17q11.2 in NF type 1 (NF1, and on chromosome 22-22q12.2 in NF type 2. The disorder is characterized by considerable heterogeneity of clinical expression. NF1 is the form with the most characteristic ocular manifestations. Lisch nodules of the iris are among the well-known diagnostic criteria for the disease. Glaucoma and associated globe enlargement have been described in a significant proportion of patients with NF1 and orbital–facial involvement. Optic nerve glioma may cause strabismus and proptosis, and palpebral neurofibroma may reach considerable size and occasionally show malignant transformation. Near infrared reflectance has greatly contributed to enhancing our knowledge on choroidal alterations in NF1. Indeed, some authors have proposed to include these among the diagnostic criteria. Optical coherence tomography has given new insight on retinal alterations and is a noninvasive tool in the management of optic nerve gliomas in children. Ocular manifestations in NF type 2 can range from early-onset cataracts in up to 80% of cases to optic nerve hamartomas and combined pigment epithelial and retinal hamartomas. Keywords: neurofibromatosis, ophthalmic, optical coherence tomography, infrared reflectance, choroideal nodules, Lisch nodules

  3. Prevention of Childhood Blindness through the Integration with ...

    African Journals Online (AJOL)

    Objective: The prevention of childhood blindness through the provision of preventive services at the community level, specialized surgical services in ophthalmic units and the provision of devices to correct low and services to children with established visual loss. Materials and methods: A series of free surgical cataract eye ...

  4. Rebamipide ophthalmic suspension for the treatment of dry eye syndrome: a critical appraisal

    Directory of Open Access Journals (Sweden)

    Kashima T

    2014-05-01

    Full Text Available Tomoyuki Kashima,1 Hirotaka Itakura,1,2 Hideo Akiyama,1 Shoji Kishi11Department of Ophthalmology, Gunma University, School of Medicine, Maebashi, Gunma, Japan; 2Department of Ophthalmology, Maebashi Red Cross Hospital, Maebashi, Gunma, JapanAbstract: Rebamipide was initially developed and approved for use in treating gastric ulcers and lesions associated with gastritis. Discovery of its ability to increase gastric mucin led to investigations of its effect on ocular surface mucin and the subsequent development for use in dry eye patients. Investigations have confirmed that rebamipide increases corneal and conjunctival mucin-like substances along with improving corneal and conjunctival injury. Clinically, rebamipide ophthalmic suspensions can effectively treat tear deficiency and mucin-caused corneal epithelial damage, and can restore the microstructure responsible for tear stability. Topical rebamipide has also been shown to be effective in treating other ocular surface disorders such as lagophthalmos, lid wiper epitheliopathy, and persistent corneal erosion. Rebamipide’s ability to modify epithelial cell function, improve tear stability, and suppress inflammation in the absence of any known major side effects suggest that it may be a beneficial first drug of choice for severe dry eye treatment and other ocular surface disorders. This review summarizes the history and development of this innovative dry eye treatment from its initial use as an effective stomach medication to its current use in the treatment of dry eye in Japan.Keywords: quinolinone derivative, tear deficiency, ocular surface disorder, mucin secretion, Mucosta

  5. Impact of a structured surgical curriculum on ophthalmic resident cataract surgery complication rates.

    Science.gov (United States)

    Rogers, Gina M; Oetting, Thomas A; Lee, Andrew G; Grignon, Connie; Greenlee, Emily; Johnson, A Tim; Beaver, Hilary A; Carter, Keith

    2009-11-01

    To determine whether institution of a structured surgical curriculum for ophthalmology residents decreased the rate of sentinel surgical complications. Veterans Affairs Medical Center, Des Moines, Iowa, USA. A retrospective review was performed of third-year ophthalmic resident quality-assurance surgical outcomes data at a single residency-training site from 1998 to 2008. The primary outcome measure was defined as a sentinel event; that is, a posterior capsule tear (with or without vitreous loss) or vitreous loss (from any cause) occurring during a resident-performed case. The study population was divided into 2 groups. Group 1 comprised surgical cases of residents trained before the surgical curriculum change (academic years 1998 to 2003) and Group 2, surgical cases of residents trained with the enhanced curriculum (academic years 2004 to 2008). Data from 1 year (academic year 2003 to 2004) were excluded because the transition to the enhanced curriculum occurred during that period. The data were analyzed and adjusted for surgical experience. In Group 1 (before institution of surgical curriculum), there were 823 cases with 59 sentinel complications. In Group 2 (after institution of surgical curriculum), there were 1009 cases with 38 sentinel complications. There was a statistically significant reduction in the sentinel complication rate, from 7.17% before the curriculum changes to 3.77% with the enhanced curriculum (P = .001, unpaired 2-tailed t test). Implementation of a structured surgical curriculum resulted in a statistically significant reduction in sentinel event complications, even after adjusting for surgical experience.

  6. Five-decade profile of women in leadership positions at ophthalmic publications.

    Science.gov (United States)

    Mansour, Ahmad M; Shields, Carol L; Maalouf, Fadi C; Massoud, Vicky A; Jurdy, Lama; Mathysen, Danny G P; Jaafar, Dalida; Aclimandos, Wagih

    2012-11-01

    To evaluate the balance between the sexes of published ophthalmic material at the editorial, reviewer, and author levels. Cross-sectional study of 3 journals, American Journal of Ophthalmology, Archives of Ophthalmology, and Ophthalmology, for 1969, 1979, 1989, 1999, and 2009. The data were compared with ophthalmologist-in-training and physician profile in major contributing states from North America and Europe during the same period. Of the 3 major ophthalmology journals, none had a female editor-in-chief. For all journals, the proportion of editorial board members who were women increased from 3.3% in 1969 to 18.8% in 2009. For all journals and all years, women composed a higher proportion of first authors (29.2% in 2009) compared with senior authors (22.9% in 2009), reviewers (18.9% in 2009), or assistant editors (12.5% in 2009). There was an abrupt shift toward women after 1989 in first authorship in Ophthalmology (1969, 4.6%; 1979, 5.4%; 1989, 12.3%; and 1999, 20.2%), Archives of Ophthalmology (1969, 6.6%; 1979, 5.1%; 1989, 15.6%; and 1999, 28.6%), and American Journal of Ophthalmology (1969, 5.6%; 1979, 4.2%; 1989, 9.2%; and 1999, 23.9%). There was also an abrupt increase in female senior authorship for American Journal of Ophthalmology after 1989 (1979, 8.5%; 1989, 8.1%; and 1999, 18.3%). The increase in female first authorship during the 5 decades was parallel with the increase in US female physicians. Women ophthalmologists are authoring publications in increasing numbers that match their prevalence in the academic and overall workforce. However, all editors are men. This discrepancy relates to the relatively younger generation of female ophthalmologists or selection bias, a subject that requires further investigation.

  7. Sustained ophthalmic delivery of highly soluble drug using pH-triggered inner layer-embedded contact lens.

    Science.gov (United States)

    Zhu, Qiang; Cheng, Hongbo; Huo, Yingnan; Mao, Shirui

    2018-06-10

    In the present work the feasibility of using inner layer-embedded contact lenses (CLs) to achieve sustained release of highly water soluble drug, betaxolol hydrochloride (BH) on the ocular surface was investigated. Blend film of cellulose acetate and Eudragit S100 was selected as the inner layer, while silicone hydrogel was used as outer layer to construct inner layer-embedded contact lenses. Influence of polymer ratio in the blend film on in vitro drug release behavior in phosphate buffered solution or simulated tear fluid was studied and drug-polymer interaction, erosion and swelling of the blend film were characterized to better understand drug-release mechanism. Storage stability of the inner layer-embedded contact lenses in phosphate buffer solution was also conducted, with ignorable drug loss and negligible change in drug release pattern within 30 days. In vivo pharmacokinetic study in rabbits showed sustained drug release for over 240 h in tear fluid, indicating prolonged drug precorneal residence time. In conclusion, cellulose acetate/Eudragit S100 inner layer-embedded contact lenses are quite promising as controlled-release carrier of highly water soluble drug for ophthalmic delivery. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Device-Centric Monitoring for Mobile Device Management

    OpenAIRE

    Chircop, Luke; Colombo, Christian; Pace, Gordon J.

    2016-01-01

    The ubiquity of computing devices has led to an increased need to ensure not only that the applications deployed on them are correct with respect to their specifications, but also that the devices are used in an appropriate manner, especially in situations where the device is provided by a party other than the actual user. Much work which has been done on runtime verification for mobile devices and operating systems is mostly application-centric, resulting in global, device-centri...

  9. Microbiological evaluation of various parameters in ophthalmic operating rooms. The need to establish guidelines.

    Directory of Open Access Journals (Sweden)

    Kelkar Uday

    2003-01-01

    Full Text Available Purpose: Postoperative infections can be caused by a contaminated environment, unsterile equipment, contaminated surfaces, and infected personnel as well as contaminated disinfectants. In order to establish guidelines for microbiological monitoring, a detailed microbiological surveillance was carried out in an ophthalmic hospital. Method: Over a period of 21 months, we assessed environmental Bacteria Carrying Particle (BCP load and surface samples weekly (n=276; the autoclaving system once a month and repeated whenever the process failed (n= 24; the air conditioning filters for fungal growth once in four months (n = 15, and the disinfectant solution for contamination once in two months (n = 10. Additionally, the personnel involved directly in surgery were screened for potential pathogens such as Staphylococcus aureus and β haemolytic streptococci. Result: On 14 (5.07% occasions the environment in the operating rooms had a significant risk of airborne infections. Sterilisation of instruments in the autoclaves was unsatisfactory on 4 (16.66 % occasions. Samples from the filters of the air-conditioning units yielded potentially pathogenic fungi on 3 (20% occasions. Personnel sampling revealed that 5 (8.77% individuals harboured β haemolytic Streptococci in the throat and 4 (7.01 % harboured S. aureus in the nasal cavity. The samples of disinfectant in use were not contaminated. Conclusion: There is a need to standardise microbiological evaluation protocols for operating rooms.

  10. Selected ophthalmic diagnostic tests, bony orbit anatomy, and ocular histology in sambar deer (Rusa unicolor).

    Science.gov (United States)

    Oriá, Arianne P; Gomes Junior, Deusdete C; Oliveira, Alberto Vinícius D; Curvelo, Victor P; Estrela-Lima, Alessandra; Pinna, Melissa H; Meneses, Íris D S; Filho, Emanoel F M; Ofri, Ron

    2015-01-01

    The purpose of this study was to establish reference values for diagnostic ophthalmic tests in sambar deer (Rusa unicolor) as well as to describe the most relevant features of the bony orbital anatomy and ocular histology. Twenty healthy animals, free living in a forest reserve, that were captured for clinical evaluation as part of a health survey were evaluated. Schirmer tear test-1 (STT1), conjunctival microbiota, intraocular pressure (IOP), conjunctival cytology, anatomy of the bony orbit, and ocular histology were studied. Mean ± SD STT1 and IOP values were 18.8 ± 4.7 mm and 11.4 ± 2.8 mmHg, respectively. IOP was significantly higher in adult (4-8 years) animals (P = 0.04). Bacterial growth was present in 100% of the samples, with a prevalence for Staphylococcus sp. and Bacillus sp. The conjunctival cytology revealed predominance of columnar epithelial cells with mild pigmentation. The sambar deer orbit is completely encompassed by bone. The ocular histology was very similar to most mammalians. The findings in this study will be useful in the diagnosis of ocular diseases in Rusa unicolor. © 2014 American College of Veterinary Ophthalmologists.

  11. 78 FR 42531 - Prospective Grant of Exclusive License: Ophthalmic Diagnostic Devices

    Science.gov (United States)

    2013-07-16

    ... (HHS Ref. No. E-279-2006/0) to OptoBiometrics Designs, Inc., a company incorporated under the laws of the State of California having its headquarters in Pleasant Hill, California. The United States of...

  12. Complex carotid cavernous sinus fistulas Barrow type D: endovascular treatment via the ophthalmic vein, imaging control with standardized MRI, long-term results; Interdisziplinaere Embolisation spontaner Karotis-Cavernosus-Fisteln Typ D nach Barrow ueber die Vena ophthalmica: klinische Langzeitergebnisse und kernspintomografische Befunde

    Energy Technology Data Exchange (ETDEWEB)

    Struffert, T.; Grunwald, I.Q.; Reith, W. [Abteilung fuer Diagnostische und Interventionelle Neuroradiologie, Universitaetsklinikum des Saarlandes (Germany); Muecke, I. [Klinik fuer Augenheilkunde, Universitaetsklinikum des Saarlandes (Germany)

    2007-04-15

    Purpose: Since feeding arteries from both the internal and external carotid artery are common, cavernous fistulas of Barrow type D are difficult to treat. Embolization using the transarterial approach is considered to be the standard therapy. However, it is often impossible to embolize feeders from the internal carotid artery. The transorbital approach after anterior orbitotomy through the ophthalmic vein is an alternative in this complex situation. The following reports our experience with three female patients who underwent transvenous embolization. Procedural success was documented using standardized MRI and clinical reevaluation. Materials and Methods: Three female patients between 57 and 78 years of age were diagnosed with carotid cavernous fistulas by conventional angiogram. All patients were suffering from exophthalmus and visual impairment. Two patients showed secondary glaucoma and diplopia. In one patient we performed a technically successful transarterial embolization using particles, but no relevant improvement of the patient's condition was seen. Transfemoral transvenous access via the sinus petrosus was not possible in any patient. All patients were then embolized via the ophthalmic vein using GDC detachable coils. All patients were clinically reevaluated by an ophthalmologist. Also a standardized MRI was performed for documentation. Follow-up was performed for the first patient for 32 months, for the second patient for 34 months and for the third patient for 50 months. Results: Transvenous embolization was technically successful in all three cases. Clinical symptoms disappeared rapidly. Postprocedural MRI showed a symmetric diameter of the ophthalmic vein. Venous congestion of the orbit caused by fatty tissue edema regressed completely. Contrast-enhanced magnetic resonance angiography showed normal arterial vessels without evidence of fistula. (orig.)

  13. Shortcomings of the industrial quality assurance of {sup 106}Ru ophthalmic plaques; Therapierelevante Schwachstellen bei der industriellen Qualitaetssicherung von {sup 106}Ru-Augenapplikatoren

    Energy Technology Data Exchange (ETDEWEB)

    Kaulich, T.W.; Nuesslin, F. [Universitaetsklinik fuer Radioonkologie, Tuebingen (Germany). Abt. Medizinische Physik; Zurheide, J. [BrainLAB AG, Heimstetten (Germany); Fluehs, D. [Abt. Strahlentherapie, Bereich klinische Strahlenphysik, Universitaetsklinikum Essen (Germany); Haug, T. [Isotopenlabor der Univ. Tuebingen (Germany); Bamberg, M. [Abt. Radioonkologie, Universitaetsklinik fuer Radioonkologie, Tuebingen (Germany)

    2001-11-01

    Background: Beta emitting {sup 106}Ru applicators manufactured by Bebig GmbH (Berlin, Germany) are widely used to treat intraocular tumors. The applicators are fixed to the bulbus and removed after several days. The following therapy relevant defects have been detected by an internal clinical acceptance test: risk of leakage and inconsistent dose-rate specifications by the manufacturer. In the meantime, components of the internal clinical acceptance test have been adopted successfully by the manufacturer of the {sup 106}Ru ophthalmic plaques. Material and Method: {sup 106}Ru ophthalmic plaques were tested with the following internal clinical acceptance tests: visual inspection, surface contamination, leakage, and dose-rate verification. The surface contamination test consists of a wet wipe test at moderate pressure. For the leakage test of the {sup 106}Ru ophthalmic plaques a clinically relevant scenario was developed in which the contact of the applicator with human tissue is simulated. In the course of it the applicator is inserted into Ringer's solution for several days. The certified energy dose-rate statements of the manufacturer are examined with a 1 mm{sup 3} plastic scintillator for consistency. (orig.) [German] Hintergrund: {sup 106}Ru-Augenapplikatoren der Fa. Bebig (Berlin) werden zur strahlentherapeutischen Behandlung von intraokularen Tumoren eingesetzt. Die Applikatoren werden sklerakontaktierend am Bulbus fixiert und nach mehreren Tagen wieder entfernt. Durch eine klinikinterne Eingangspruefung wurden folgende therapierelevante Maengel bei den Augenapplikatoren entdeckt: mangelhafte Dichtheit und inkonsistente Dosisleistungsangaben des Herstellers. Ein Teil dieser klinikinternen Eingangspruefung wurde inzwischen vom Hersteller der {sup 106}Ru-Augenapplikatoren uebernommen und erfolgreich eingesetzt. Material und Methode: Es wurden {sup 106}Ru-Augenapplikatoren durch folgende klinikinterne Eingangspruefungen getestet: optische Inspektion

  14. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow.

    Science.gov (United States)

    Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T

    2018-01-01

    New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.

  15. Mechanistic modeling of ophthalmic drug delivery to the anterior chamber by eye drops and contact lenses.

    Science.gov (United States)

    Gause, Samuel; Hsu, Kuan-Hui; Shafor, Chancellor; Dixon, Phillip; Powell, Kristin Conrad; Chauhan, Anuj

    2016-07-01

    Ophthalmic drug for the anterior chamber diseases are delivered into tears by either eye drops or by extended release devices placed in the eyes. The instilled drug exits the eye through various routes including tear drainage into the nose through the canaliculi and transport across various ocular membranes. Understanding the mechanisms relevant to each route can be useful in predicting the dependency of ocular bioavailability on various formulation parameters, such as drug concentration, salinity, viscosity, etc. Mathematical modeling has been developed for each of the routes and validated by comparison with experiments. The individual models can be combined into a system model to predict the fraction of the instilled drug that reaches the target. This review summarizes the individual models for the transport of drugs across the cornea and conjunctiva and the canaliculi tear drainage. It also summarizes the combined tear dynamics model that can predict the ocular bioavailability of drugs instilled as eye drops. The predictions from the individual models and the combined model are in good agreement with experimental data. Both experiments and models predict that the corneal bioavailability for drugs delivered through eye drops is less than 5% due to the small area of the cornea in comparison to the conjunctiva, and the rapid clearance of the instilled solution by tear drainage. A contact lens is a natural choice for delivering drugs to the cornea due to the placement of the contact in the immediate vicinity of the cornea. The drug released by the contact towards the cornea surface is trapped in the post lens tear film for extended duration of at least 30min allowing transport of a large portion into the cornea. The model predictions backed by in vivo animal and clinical data show that the bioavailability increases to about 50% with contact lenses. This realization has encouraged considerable research towards delivering ocular drugs by contact lenses. Commercial

  16. Ontology-Based Device Descriptions and Device Repository for Building Automation Devices

    Directory of Open Access Journals (Sweden)

    Dibowski Henrik

    2011-01-01

    Full Text Available Device descriptions play an important role in the design and commissioning of modern building automation systems and help reducing the design time and costs. However, all established device descriptions are specialized for certain purposes and suffer from several weaknesses. This hinders a further design automation, which is strongly needed for the more and more complex building automation systems. To overcome these problems, this paper presents novel Ontology-based Device Descriptions (ODDs along with a layered ontology architecture, a specific ontology view approach with virtual properties, a generic access interface, a triple store-based database backend, and a generic search mask GUI with underlying query generation algorithm. It enables a formal, unified, and extensible specification of building automation devices, ensures their comparability, and facilitates a computer-enabled retrieval, selection, and interoperability evaluation, which is essential for an automated design. The scalability of the approach to several ten thousand devices is demonstrated.

  17. Influence of container structures and content solutions on dispensing time of ophthalmic solutions

    Directory of Open Access Journals (Sweden)

    Keiji Yoshikawa

    2010-05-01

    Full Text Available Keiji Yoshikawa1, Hiroshi Yamada21Yoshikawa Eye Clinic, Tokyo, Japan; 2Santen Pharmaceutical Co., Ltd., Osaka, JapanPurpose: To investigate the influence of container structures and content solutions on the time of dispensing from eye dropper bottles.Methods: Eye dropper bottle models, solution models (filtrate water/surfactant solution and a dispensing time measuring apparatus were prepared to measure the dispensing time.Results: With filtrate water and pressure thrust load of 0.3 MPa, the dispensing time significantly increased from 1.1 ± 0.5 seconds to 4.6 ± 1.1 seconds depending on the decrease of inner aperture diameters from 0.4 mm to 0.2 mm (P < 0.0001. When using the bottle models with inner aperture diameters of 0.4 mm or larger, the dispensing time became constant. The dispensing time using surfactant solution showed the same tendency as above. When pressure thrust load was large (0.07 MPa, the solution flew out continuously with inner aperture diameters of 0.4 mm or larger and the dispensing time could not be measured. The inner aperture diameter most strongly explained the variation of the dispensing time in both the content solutions in the multiple linear regression analysis (filtrate water: 46%, R2 = 0.462, surfactant solution: 56%, R2 = 0.563.Conclusions: Among content solutions and container structures, the dispensing time was mostly influenced by the diameter of the inner aperture of bottles.Keywords: dispensing time, model eye dropper bottle, model ophthalmic solution, nozzle internal space volume, nozzle inner aperture diameter

  18. Multi-Device to Multi-Device (MD2MD Content-Centric Networking Based on Multi-RAT Device

    Directory of Open Access Journals (Sweden)

    Cheolhoon Kim

    2017-11-01

    Full Text Available This paper proposes a method whereby a device can transmit and receive information using a beacon, and also describes application scenarios for the proposed method. In a multi-device to multi-device (MD2MD content-centric networking (CCN environment, the main issue involves searching for and connecting to nearby devices. However, if a device can’t find another device that satisfies its requirements, the connection is delayed due to the repetition of processes. It is possible to rapidly connect to a device without repetition through the selection of the optimal device using the proposed method. Consequently, the proposed method and scenarios are advantageous in that they enable efficient content identification and delivery in a content-centric Internet of Things (IoT environment, in which multiple mobile devices coexist.

  19. Graphene device and method of using graphene device

    Science.gov (United States)

    Bouchiat, Vincent; Girit, Caglar; Kessler, Brian; Zettl, Alexander K.

    2015-08-11

    An embodiment of a graphene device includes a layered structure, first and second electrodes, and a dopant island. The layered structure includes a conductive layer, an insulating layer, and a graphene layer. The electrodes are coupled to the graphene layer. The dopant island is coupled to an exposed surface of the graphene layer between the electrodes. An embodiment of a method of using a graphene device includes providing the graphene device. A voltage is applied to the conductive layer of the graphene device. Another embodiment of a method of using a graphene device includes providing the graphene device without the dopant island. A dopant island is placed on an exposed surface of the graphene layer between the electrodes. A voltage is applied to the conductive layer of the graphene device. A response of the dopant island to the voltage is observed.

  20. Humanitarian Use Devices/Humanitarian Device Exemptions in cardiovascular medicine.

    Science.gov (United States)

    Kaplan, Aaron V; Harvey, Elisa D; Kuntz, Richard E; Shiran, Hadas; Robb, John F; Fitzgerald, Peter

    2005-11-01

    The Second Dartmouth Device Development Symposium held in October 2004 brought together leaders from the medical device community, including clinical investigators, senior representatives from the US Food and Drug Administration, large and small device manufacturers, and representatives from the financial community to examine difficult issues confronting device development. The role of the Humanitarian Use Device/Humanitarian Device Exemption (HUD/HDE) pathway in the development of new cardiovascular devices was discussed in this forum. The HUD/HDE pathway was created by Congress to facilitate the availability of medical devices for "orphan" indications, ie, those affecting HDEs have been granted (23 devices, 6 diagnostic tests). As the costs to gain regulatory approval for commonly used devices increase, companies often seek alternative ways to gain market access, including the HUD/HDE pathway. For a given device, there may be multiple legitimate and distinct indications, including indications that meet the HUD criteria. Companies must choose how and when to pursue each of these indications. The consensus of symposium participants was for the HUD/HDE pathway to be reserved for true orphan indications and not be viewed strategically as part of the clinical development plan to access a large market.

  1. Total retinal detachments due to retinoblastoma: Outcomes following intra-arterial chemotherapy/ophthalmic artery chemosurgery.

    Directory of Open Access Journals (Sweden)

    Megan A Rowlands

    Full Text Available To report on the rate and timing of retinal reattachment and outcomes for retinoblastoma children who have total retinal detachments at presentation to our center and were treated with intra-arterial chemotherapy (ophthalmic artery chemosurgery, OAC.Single-center retrospective review of retinoblastoma patients who presented with total retinal detachments and were subsequently treated with OAC at MSKCC between May 2006 and July 2016. Endpoints were retinal detachment resolution, visual function, ERG amplitude, ocular survival, and patient survival from metastases.87 eyes of 84 retinoblastoma patients were included. Using a survival multistate model, by 36 months of follow-up, there was a 54% cumulative probability of complete retinal reattachment and a 76% probability of partial reattachment. 24% of eyes that completely reattached received only OAC without any prior or adjuvant treatments. Eyes that completely reattached were significantly more likely to have been diagnosed at a younger age (p<0.0001 and to have greater initial ERG values (p = 0.006. At final follow-up, 14% of eyes had gained at least 25 μV of ERG activity, and 8.0% had achieved hand motion vision or better, including one to 20/60. 13% of eyes were enucleated. No patient died from metastatic disease, and only one developed metastases.OAC can successfully treat previously considered "non-salvageable" retinoblastoma eyes with total retinal detachments, promote retinal reattachment in the majority of eyes, and preserve ocular and patient survival.

  2. Automatic diagnosis of imbalanced ophthalmic images using a cost-sensitive deep convolutional neural network.

    Science.gov (United States)

    Jiang, Jiewei; Liu, Xiyang; Zhang, Kai; Long, Erping; Wang, Liming; Li, Wangting; Liu, Lin; Wang, Shuai; Zhu, Mingmin; Cui, Jiangtao; Liu, Zhenzhen; Lin, Zhuoling; Li, Xiaoyan; Chen, Jingjing; Cao, Qianzhong; Li, Jing; Wu, Xiaohang; Wang, Dongni; Wang, Jinghui; Lin, Haotian

    2017-11-21

    Ocular images play an essential role in ophthalmological diagnoses. Having an imbalanced dataset is an inevitable issue in automated ocular diseases diagnosis; the scarcity of positive samples always tends to result in the misdiagnosis of severe patients during the classification task. Exploring an effective computer-aided diagnostic method to deal with imbalanced ophthalmological dataset is crucial. In this paper, we develop an effective cost-sensitive deep residual convolutional neural network (CS-ResCNN) classifier to diagnose ophthalmic diseases using retro-illumination images. First, the regions of interest (crystalline lens) are automatically identified via twice-applied Canny detection and Hough transformation. Then, the localized zones are fed into the CS-ResCNN to extract high-level features for subsequent use in automatic diagnosis. Second, the impacts of cost factors on the CS-ResCNN are further analyzed using a grid-search procedure to verify that our proposed system is robust and efficient. Qualitative analyses and quantitative experimental results demonstrate that our proposed method outperforms other conventional approaches and offers exceptional mean accuracy (92.24%), specificity (93.19%), sensitivity (89.66%) and AUC (97.11%) results. Moreover, the sensitivity of the CS-ResCNN is enhanced by over 13.6% compared to the native CNN method. Our study provides a practical strategy for addressing imbalanced ophthalmological datasets and has the potential to be applied to other medical images. The developed and deployed CS-ResCNN could serve as computer-aided diagnosis software for ophthalmologists in clinical application.

  3. The use of retinal photography in non-ophthalmic settings and its potential for neurology

    Science.gov (United States)

    Pérez, Mario A.; Bruce, Beau B.; Newman, Nancy J.; Biousse, Valérie

    2012-01-01

    Background Ocular fundus examination is an important element of the neurological examination. However, direct ophthalmoscopy is difficult to perform without pupillary dilation and requires extensive practice to accurately recognize optic nerve and retinal abnormalities. Recent studies have suggested that digital retinal photography can replace direct ophthalmoscopy in many settings. Review Summary Ocular fundus imaging is routinely used to document and monitor disease progression in ophthalmology. Advances in optical technology have made it easier to obtain high-quality retinal imaging, even without pupillary dilation. Retinal photography has a high sensitivity, specificity, and inter-/intra-examination agreement compared to in-person ophthalmologist examination, suggesting that photographs can be used in lieu of ophthalmoscopy in many clinical situations. Non-mydriatic retinal photography has recently gained relevance as a helpful tool for diagnosing neuro-ophthalmologic disorders in the emergency department. Additionally, several population-based studies have used retinal imaging to relate ophthalmic abnormalities to the risk of hypertension, renal dysfunction, cardiovascular mortality, subclinical and clinical stroke, and cognitive impairment. The possibility of telemedical consultation offered by digital retinal photography has already increased access to timely and accurate subspecialty care, particularly for underserved areas. Conclusion Retinal photography (even without pupillary dilation) has become increasingly available to medical fields outside of ophthalmology, allowing for faster and more accurate diagnosis of various ocular, neurologic and systemic disorders. The potential for telemedicine may provide the additional benefits of improving access to appropriate urgent consultation in both clinical and research settings. PMID:23114666

  4. Vision impairment and corrective considerations of civil airmen.

    Science.gov (United States)

    Nakagawara, V B; Wood, K J; Montgomery, R W

    1995-08-01

    Civil aviation is a major commercial and technological industry in the United States. The Federal Aviation Administration (FAA) is responsible for the regulation and promotion of aviation safety in the National Airspace System. To guide FAA policy changes and educational programs for aviation personnel about vision impairment and the use of corrective ophthalmic devices, the demographics of the civil airman population were reviewed. Demographic data from 1971-1991 were extracted from FAA publications and databases. Approximately 48 percent of the civil airman population is equal to or older than 40 years of age (average age = 39.8 years). Many of these aviators are becoming presbyopic and will need corrective devices for near and intermediate vision. In fact, there has been approximately a 12 percent increase in the number of aviators with near vision restrictions during the past decade. Ophthalmic considerations for prescribing and dispensing eyewear for civil aviators are discussed. The correction of near and intermediate vision conditions for older pilots will be a major challenge for eye care practitioners in the next decade. Knowledge of the unique vision and environmental requirements of the civilian airman can assist clinicians in suggesting alternative vision corrective devices better suited for a particular aviation activity.

  5. Growth patterns of survivors of retinoblastoma treated with ophthalmic artery chemosurgery.

    Directory of Open Access Journals (Sweden)

    Sruti S Akella

    Full Text Available Although studies from pediatric cancers (largely acute lymphoblastic leukemia have shown that patients undergoing systemic chemotherapy may experience decreased growth velocity during the treatment phase, no such data exist for retinoblastoma patients treated with systemic chemotherapy or ophthalmic artery chemosurgery (OAC. The purpose of this study is to report growth patterns of our retinoblastoma (Rb population who were treated with OAC in a retrospective, single center (Memorial Sloan Kettering Cancer Center review of 341 patients treated between 2006 and 2016. Children who only received OAC were classified as naive; those who were treated initially with systemic chemotherapy and subsequently presented to our center for OAC were termed secondary; and a small group of patients who received single-agent systemic chemotherapy prior to OAC were labeled bridge. For all patients, height and weight were recorded at monthly intervals during OAC (short-term and then annually during a follow-up period (long-term up to 3 years after treatment. Excluded from this study were children who received external radiation therapy and those with genetic syndromes, which are independently associated with growth derangements. During OAC, there was no significant difference in growth velocity between the naïve and secondary groups. In either group, number of treatments also did not affect growth rate. Three years after the end of OAC, naïve patients were in the 68th percentile by height (95% CI 61.30, 74.63 compared to secondary patients in the 61st percentile (95% CI 51.1, 71.47. Both groups were in the same weight percentiles during the first two years of follow-up but at the three-year follow-up period, naïve patients were in the 63rd percentile (95% CI 57.4, 69.4 and secondary patients were in the 60th percentile (95% CI 50.4, 69.7. OAC for retinoblastoma does not appear to impact short-term growth velocity, weight gain during the treatment period or after

  6. DeviceNet-based device-level control in SSRF

    CERN Document Server

    Leng Yong Bin; Lu Cheng Meng; Miao Hai Feng; Liu Song Qiang; Shen Guo Bao

    2002-01-01

    The control system of Shanghai Synchrotron Radiation Facility is an EPICS-based distributed system. One of the key techniques to construct the system is the device-level control. The author describes the design and implementation of the DeviceNet-based device controller. A prototype of the device controller was tested in the experiments of magnet power supply and the result showed a precision of 3 x 10 sup - sup 5

  7. The hen's egg chorioallantoic membrane (HET-CAM) test to predict the ophthalmic irritation potential of a cysteamine-containing gel: Quantification using Photoshop® and ImageJ.

    Science.gov (United States)

    McKenzie, Barbara; Kay, Graeme; Matthews, Kerr H; Knott, Rachel M; Cairns, Donald

    2015-07-25

    A modified hen's egg chorioallantoic membrane (HET-CAM) test has been developed, combining ImageJ analysis with Adobe(®) Photoshop(®). The irritation potential of an ophthalmic medicine can be quantified using this method, by monitoring damage to blood vessels. The evaluation of cysteamine containing hyaluronate gel is reported. The results demonstrated that the novel gel formulation is non-irritant to the ocular tissues, in line with saline solution (negative control). In conclusion, the modification of the established HET-CAM test can quantify the damage to minute blood vessels. These results offer the possibility to formulate cysteamine in an ocular applicable gel formulation. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Influence of GlideScope assisted endotracheal intubation on intraocular pressure in ophthalmic patients

    Directory of Open Access Journals (Sweden)

    Nauman Ahmad

    2015-01-01

    Full Text Available Background: Traditional Macintoch laryngoscopy is known to cause a rise in intraocular pressure (IOP, tachycardia and hypertension. These changes are not desirable in patients with glaucoma and open globe injury. GlideScope is a video laryngoscope that functions independent of the line of sight, reduces upward lifting forces for glottic exposure and requires less cervical neck movement for intubation, making it less stimulating than Macintosh laryngoscopy. Aim: The aim was to assess the variations in IOP and hemodynamic changes after GlideScope assisted intubation. Materials and Methods: After approval of the local Institutional Research and Ethical Board and informed patient consent, 50 adult American Society of Anesthesiologist I and II patients with normal IOP were enrolled in a prospective, randomized study for ophthalmic surgery requiring tracheal intubation. In all patients, trachea was intubated using either GlideScope or Macintoch laryngoscope. IOP of nonoperated eye, heart rate and blood pressure were measured as baseline, 1 min after induction, 1 min and 5 min after tracheal intubation. Results: IOP was not significantly different between groups before and after anesthetic induction and 5 min after tracheal intubation (P = 0.217, 0.726, and 0.110 respectively. The only significant difference in IOP was at 1 min after intubation (P = 0.041. No significant difference noted between groups in mean arterial pressure (P = 0.899, 0.62, 0.47, 0.82 respectively and heart rate (P = 0.21, 0.72, 0.07, 0.29, respectively at all measurements. Conclusion: GlideScope assisted tracheal intubation shown lesser rise in IOP at 1 min after intubation in comparison to Macintoch laryngoscope, suggesting that GlideScope may be preferable to Macintosh laryngoscope.

  9. Effectiveness of ophthalmic solution preservatives: a comparison of latanoprost with 0.02% benzalkonium chloride and travoprost with the sofZia preservative system

    Directory of Open Access Journals (Sweden)

    Lovelace Cherie

    2011-04-01

    Full Text Available Abstract Background Although in vitro and in vivo laboratory studies have suggested that benzalkonium chloride (BAK in topical ophthalmic solutions may be detrimental to corneal epithelial cells, multiple short- and long-term clinical studies have provided evidence supporting the safety of BAK. Despite the conflicting evidence, BAK is the most commonly used preservative in ophthalmic products largely due to its proven antimicrobial efficacy. This study was designed to characterize the antimicrobial performance of two commonly used topical ocular hypotensive agents that employ different preservative systems: latanoprost 0.005% with 0.02% BAK and travoprost 0.004% with sofZia, a proprietary ionic buffer system. Methods Each product was tested for antimicrobial effectiveness by European Pharmacopoeia A (EP-A standards, the most stringent standards of the three major compendia, which specify two early sampling time points (6 and 24 hours not required by the United States Pharmacopeia or Japanese Pharmacopoeia. Aliquots were inoculated with between 105 and 106 colony-forming units of the test organisms: Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans and Aspergillus brasiliensis. Sampling and enumeration were conducted at protocol-defined time points through 28 days. Results BAK-containing latanoprost met EP-A criteria by immediately reducing all bacterial challenge organisms to the test sensitivity and fungal challenges within the first six hours while the preservative activity of travoprost with sofZia did not. Complete bacterial reduction by travoprost with sofZia was not shown until seven days into the test, and fungal reduction never exceeded the requisite 2 logs during the 28-day test. Travoprost with sofZia also did not meet EP-B criteria due to its limited effectiveness against Staphylococcus aureus. Both products satisfied United States and Japanese pharmacopoeial criteria. Conclusions Latanoprost with 0

  10. Effectiveness of ophthalmic solution preservatives: a comparison of latanoprost with 0.02% benzalkonium chloride and travoprost with the sofZia preservative system.

    Science.gov (United States)

    Ryan, Gerard; Fain, Joel M; Lovelace, Cherie; Gelotte, Karl M

    2011-04-21

    Although in vitro and in vivo laboratory studies have suggested that benzalkonium chloride (BAK) in topical ophthalmic solutions may be detrimental to corneal epithelial cells, multiple short- and long-term clinical studies have provided evidence supporting the safety of BAK. Despite the conflicting evidence, BAK is the most commonly used preservative in ophthalmic products largely due to its proven antimicrobial efficacy. This study was designed to characterize the antimicrobial performance of two commonly used topical ocular hypotensive agents that employ different preservative systems: latanoprost 0.005% with 0.02% BAK and travoprost 0.004% with sofZia, a proprietary ionic buffer system. Each product was tested for antimicrobial effectiveness by European Pharmacopoeia A (EP-A) standards, the most stringent standards of the three major compendia, which specify two early sampling time points (6 and 24 hours) not required by the United States Pharmacopeia or Japanese Pharmacopoeia. Aliquots were inoculated with between 10(5) and 10(6) colony-forming units of the test organisms: Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans and Aspergillus brasiliensis. Sampling and enumeration were conducted at protocol-defined time points through 28 days. BAK-containing latanoprost met EP-A criteria by immediately reducing all bacterial challenge organisms to the test sensitivity and fungal challenges within the first six hours while the preservative activity of travoprost with sofZia did not. Complete bacterial reduction by travoprost with sofZia was not shown until seven days into the test, and fungal reduction never exceeded the requisite 2 logs during the 28-day test. Travoprost with sofZia also did not meet EP-B criteria due to its limited effectiveness against Staphylococcus aureus. Both products satisfied United States and Japanese pharmacopoeial criteria. Latanoprost with 0.02% BAK exhibited more effective microbial protection than

  11. QoE-Aware Device-to-Device Multimedia Communications

    Directory of Open Access Journals (Sweden)

    Liang ZHOU

    2015-08-01

    Full Text Available Multimedia services over mobile device-to-device (D2D networks has recently received considerable attention. In this scenario, each device is equipped with a cellular communication interface, as well as a D2D interface over a shared medium. In this work, we study the performance properties of the mobile D2D communications in the framework of user satisfaction, and develop a fully distributed QoE-aware multimedia communication scheme (QAMCS. Specifically, we translate the opportunistic multimedia communications issue into a stochastic optimization problem, which opens up a new degree of performance to exploit. Moreover, QAMCS is designed for a heterogeneous and dynamic environment, in which user demand, device mobility, and transmission fashion may vary across different devices and applications. Importantly, QAMCS is able to maximize the user satisfaction and only needs each device to implement its own scheme individually in the absence of a central controller.

  12. Virtual MIMO Beamforming and Device Pairing Enabled by Device-to-Device Communications for Multidevice Networks

    Directory of Open Access Journals (Sweden)

    Yeonjin Jeong

    2017-01-01

    Full Text Available We consider a multidevice network with asymmetric antenna configurations which supports not only communications between an access point and devices but also device-to-device (D2D communications for the Internet of things. For the network, we propose the transmit and receive beamforming with the channel state information (CSI for virtual multiple-input multiple-output (MIMO enabled by D2D receive cooperation. We analyze the sum rate achieved by a device pair in the proposed method and identify the strategies to improve the sum rate of the device pair. We next present a distributed algorithm and its equivalent algorithm for device pairing to maximize the throughput of the multidevice network. Simulation results confirm the advantages of the transmit CSI and D2D cooperation as well as the validity of the distributive algorithm.

  13. Release strategies for making transferable semiconductor structures, devices and device components

    Science.gov (United States)

    Rogers, John A; Nuzzo, Ralph G; Meitl, Matthew; Ko, Heung Cho; Yoon, Jongseung; Menard, Etienne; Baca, Alfred J

    2014-11-25

    Provided are methods for making a device or device component by providing a multilayer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.

  14. Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture

    Science.gov (United States)

    McCown, Steven H [Rigby, ID; Derr, Kurt W [Idaho Falls, ID; Rohde, Kenneth W [Idaho Falls, ID

    2012-05-08

    Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture are described. According to one embodiment, a wireless device monitoring method includes accessing device configuration information of a wireless device present at a secure area, wherein the device configuration information comprises information regarding a configuration of the wireless device, accessing stored information corresponding to the wireless device, wherein the stored information comprises information regarding the configuration of the wireless device, comparing the device configuration information with the stored information, and indicating the wireless device as one of authorized and unauthorized for presence at the secure area using the comparing.

  15. Class 1 devices case studies in medical devices design

    CERN Document Server

    Ogrodnik, Peter J

    2014-01-01

    The Case Studies in Medical Devices Design series consists of practical, applied case studies relating to medical device design in industry. These titles complement Ogrodnik's Medical Device Design and will assist engineers with applying the theory in practice. The case studies presented directly relate to Class I, Class IIa, Class IIb and Class III medical devices. Designers and companies who wish to extend their knowledge in a specific discipline related to their respective class of operation will find any or all of these titles a great addition to their library. Class 1 Devices is a companion text to Medical Devices Design: Innovation from Concept to Market. The intention of this book, and its sister books in the series, is to support the concepts presented in Medical Devices Design through case studies. In the context of this book the case studies consider Class I (EU) and 510(k) exempt (FDA) . This book covers classifications, the conceptual and embodiment phase, plus design from idea to PDS. These title...

  16. Helical CT finding of carotid-cavernous fistula: a sign of early enhancing superior ophthalmic vein

    International Nuclear Information System (INIS)

    Kim, Jae Hyung; Na, Dong Gyu; Byun, Hong Sik; Ryoo, Jae Wook

    2000-01-01

    The purpose of this study was to determine the diagnostic value of a sign of early enhancing superior ophthalmic vein (SOV), as seen on helical CT images in patients with carotid-cavernous fistula (CCF). This study involved 16 patients with CCF and 28 control patients. Axial CT images with scanning delays of 30 seconds following bolus injection of contrast material (90 mL, 3 mL/sec) were obtained, and this procedure was followed by coronal CT imaging. To determine the presence or absence of early enhancement or, dilatation of the SOV, bulging of the cavernous sinus, and enlargement of extraocular muscle, CT images were analysed by three observers in a blinded, random manner. Early enhancement of SOV was determined to be present where enhancement of the SOV was similar to or stronger than that of the ipsilateral posterior cerebral artery. A sign of early enhancing SOV was seen in 14 of the 16 patients with CCF but in no control patients (88% sensitivity and 100% specificity). The respective sensitivity and specificity of other CT features were 71% and 100% (dilatation of the SOV, as seen on axial images), 60% and 83% (dilatation of the SOV, as seen on coronal images), 71% and 89% (dilatation of the cavernous sinus), and 65% and 98% (enlargement of extraocular muscle). A sign of early enhancing SOV is a characteristic and specific CT finding of CCF, and is useful for the diagnosis of CCF. (author)

  17. Preformulation study of methazolamide for topical ophthalmic delivery: physicochemical properties and degradation kinetics in aqueous solutions.

    Science.gov (United States)

    Jiang, Sunmin; Wang, Fengzhen; Zhu, Shuning; Zhang, Xiumei; Guo, Zhigang; Li, Rui; Xu, Qunwei

    2013-05-20

    Methazolamide (MTZ) is an anti-glaucoma drug. The present paper aims to characterize the physicochemical properties and degradation kinetics of MTZ to provide a basis for topical ophthalmic delivery. With the increase in pH (pH 5.5-8.0) of aqueous solution, the solubility of the compound increased while the partition coefficient (Ko/w) which was estimated in the system n-octanol/aqueous solution decreased. The degradation of MTZ in aqueous solution followed pseudo-first-order kinetic. The degradation rate kpH is the rate in the absence of buffer catalysis. Plotting the natural logarithm of kpH versus the corresponding pH value gave a V-shaped pH-rate profile with a maximum stability at pH 5.0. The degradation rate constants as a function of the temperature obeyed the Arrhenius equation (R(2)=0.9995 at pH 7.0 and R(2)=0.9955 at pH 9.0, respectively). A decrease in ionic strength and buffer concentration displayed a stabilizing effect on MTZ. Buffer species also influenced the MTZ hydrolysis. Phosphate buffer system was more catalytic than tris and borate buffer systems. In brief, it is important to consider the physicochemical properties and the stability of MTZ during formulation. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Ophthalmic manifestations and histopathology of xeroderma pigmentosum: two clinicopathological cases and a review of the literature.

    Science.gov (United States)

    Ramkumar, Hema L; Brooks, Brian P; Cao, Xiaoguang; Tamura, Deborah; Digiovanna, John J; Kraemer, Kenneth H; Chan, Chi-Chao

    2011-01-01

    Xeroderma pigmentosum is a rare, autosomal recessive disease caused by a defect in DNA repair. Patients with xeroderma pigmentosum often have cutaneous and ocular sun sensitivity, freckle-like skin pigmentation, multiple skin and eye cancers, and, in some patients, progressive neurodegeneration. Xeroderma pigmentosum predominantly affects the ultraviolet (UV) exposed ocular surface, resulting in eyelid atrophy and cancers, corneal dryness, exposure keratopathy, and conjunctival tumors. We report the clinical history and ocular pathology of two white women who had xeroderma pigmentosum with neurological degeneration: Case 1 (died at age 44 years) and Case 2 (died at age 45 years). Case 1, with mutations in the XPA gene, had more than 180 basal cell carcinomas of her skin and eyelids and died from complications of neurodegeneration. Case 2, with mutations in the XPD gene, was sun-protected and had three skin cancers. She died from complications of neurodegeneration and pneumonia. Both patients had bilateral pinguecula, corneal pannus, and exposure keratopathy. Case 1 had bilateral optic atrophy, and Case 2 had bilateral peripheral retinal pigmentary degeneration. Both patients developed retinal gliosis. The ophthalmic manifestations and pathology of xeroderma pigmentosum are discussed and reviewed with respect to this report and other cases in the literature. These cases illustrate the role of DNA repair in protection of the eyes from UV damage and neurodegeneration of the retina. Published by Elsevier Inc.

  19. Complicações oftálmicas em pacientes com tumores malignos extra-orbitários Ophthalmic complications in patients with extraorbital malignant tumors

    Directory of Open Access Journals (Sweden)

    Ana Célia Baptista

    2003-10-01

    Full Text Available OBJETIVO: Correlacionar as complicações oftálmicas, presentes em pacientes portadores de tumores malignos extra-orbitários, com o sítio de origem e diagnóstico histopatológico destas neoplasias, por meio de tomografia computadorizada. MÉTODOS: Foram estudados retrospectivamente, por tomografia computadorizada, 29 pacientes com neoplasias malignas extra-orbitárias, sem qualquer tratamento prévio do tumor, e evidência clínico-radiológica de comprometimento orbitário associado. RESULTADOS: Houve predomínio do carcinoma epidermóide (28%, seguido pelo carcinoma basocelular (14%. As complicações oftálmicas mais comumente observadas foram proptose (38%, epífora (24% e dor ocular (24%. Redução da acuidade visual foi referida em 14 % dos casos. Os sítios de origem mais comuns das neoplasias foram o seio maxilar (28%, o seio etmoidal (17% e a pele e subcutâneo da face (17%. Proptose ocular foi causada predominantemente por tumores não carcinomatosos e tumores originados no seio etmoidal, ao passo que epífora ocorreu preferencialmente nos casos de tumores carcinomatosos e de neoplasias do seio maxilar. Redução da motilidade ocular, irritação ocular e secreção no olho foram as complicações oftálmicas mais freqüentes em pacientes com tumores dos anexos oculares, ao passo que dor ocular foi a complicação oftálmica dominante nos pacientes com neoplasias originadas na pele e subcutâneo da face. CONCLUSÕES: Os autores sugerem que, diante de paciente com epífora e massa maxilo-nasal, carcinoma do seio maxilar deve ser considerado primariamente no diagnóstico diferencial da lesão. Da mesma forma, tumores não carcinomatosos, como sarcomas e linfomas, devem ser considerados, sobretudo no diagnóstico de pacientes com proptose e massa naso-etmoidal.OBJECTIVE: To correlate the ophthalmic complications in patients with extra-orbital malignant tumors with the site of origin and histopathologic diagnosis of the tumors by

  20. Immediate Effect of 3% Diquafosol Ophthalmic Solution on Tear MUC5AC Concentration and Corneal Wetting Ability in Normal and Experimental Keratoconjunctivitis Sicca Rat Models.

    Science.gov (United States)

    Choi, Kwang-Eon; Song, Jong-Suk; Kang, Boram; Eom, Youngsub; Kim, Hyo-Myung

    2017-05-01

    To evaluate the immediate effect of 3% diquafosol ophthalmic solution on tear MUC5AC concentration, periodic acid-Schiff (PAS)-positive goblet cells, and tear film stability in normal and keratoconjunctivitis sicca (KCS) rat models. Rats were divided into normal and KCS groups. 3% of diquafosol solution was instilled into the right eye and normal saline into the left eye in both groups. To determine the peak time of tear MUC5AC concentration, tears were collected after 3% diquafosol instillation every 5 min up to 20 min. The tear film stability and the numbers of PAS-positive goblet cells were compared in both models. After diquafosol instillation, tear MUC5AC concentration increased steadily for 15 min, at which point the MUC5AC concentration reached its peak. In both normal and KCS groups, the MUC5AC concentration at 15 min was higher after instillation of 3% diquafosol solution (17.77 ± 2.09 ng/ml in the normal group, 9.65 ± 3.51 ng/ml in the KCS group) than that after saline instillation (13.74 ± 2.87 ng/ml in the normal group, 8.19 ± 3.99 ng/ml in the KCS group) (p = 0.018 for both). The corneal wetting ability was significantly longer after instillation of 3% diquafosol solution compared with that after instillation of normal saline in the normal group (p = 0.018). The percentage of PAS-positive goblet cells after the instillation of 3% diquafosol solution was significantly lower than that after instillation of normal saline in both models (p = 0.018 for both). Diquafosol ophthalmic solution was effective in stimulating mucin secretion in both normal and KCS rat models, and the peak time of tear MUC5AC concentration was 15 min after diquafosol instillation. The increased tear MUC5AC concentration was accompanied by improved tear film stability and a decreased percentage of PAS-positive goblet cells.