WorldWideScience

Sample records for operable unit volume

  1. Operable Units

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset consists of operable unit data from multiple Superfund sites in U.S. EPA Region 8. These data were acquired from multiple sources at different times and...

  2. Molten salt coal gasification process development unit. Phase 1. Volume 1. PDU operations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kohl, A.L.

    1980-05-01

    This report summarizes the results of a test program conducted on the Molten Salt Coal Gasification Process, which included the design, construction, and operation of a Process Development Unit. In this process, coal is gasified by contacting it with air in a turbulent pool of molten sodium carbonate. Sulfur and ash are retained in the melt, and a small stream is continuously removed from the gasifier for regeneration of sodium carbonate, removal of sulfur, and disposal of the ash. The process can handle a wide variety of feed materials, including highly caking coals, and produces a gas relatively free from tars and other impurities. The gasification step is carried out at approximately 1800/sup 0/F. The PDU was designed to process 1 ton per hour of coal at pressures up to 20 atm. It is a completely integrated facility including systems for feeding solids to the gasifier, regenerating sodium carbonate for reuse, and removing sulfur and ash in forms suitable for disposal. Five extended test runs were made. The observed product gas composition was quite close to that predicted on the basis of earlier small-scale tests and thermodynamic considerations. All plant systems were operated in an integrated manner during one of the runs. The principal problem encountered during the five test runs was maintaining a continuous flow of melt from the gasifier to the quench tank. Test data and discussions regarding plant equipment and process performance are presented. The program also included a commercial plant study which showed the process to be attractive for use in a combined-cycle, electric power plant. The report is presented in two volumes, Volume 1, PDU Operations, and Volume 2, Commercial Plant Study.

  3. Phase I remedial investigation report for the 300-FF-5 operable unit, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-01-01

    The focus of this remedial investigation (RI) is the 300-FF-5 operable unit, one of five operable units associated with the 300 Area aggregate of the U.S. Department of Energy`s (DOE`s) Hanford Site. The 300-FF-5 operable unit is a groundwater operable unit beneath the 300-FF-1, 300-FF-2, and 300-FF-3 source operable units. This operable unit was designated to include all contamination detected in the groundwater and sediments below the water table that emanates from the 300-FF-1, 300-FF-2, and 300-FF-3 operable units (DOE-RL 1990a). In November 1989, the U.S. Environmental Protection Agency (EPA) placed the 300 Area on the National Priorities List (NPL) contained within Appendix B of the National Oil and Hazardous Substance Pollution Contingency Plan (NCP, 53 FR 51391 et seq.). The EPA took this action pursuant to their authority under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA, 42 USC 9601 et seq.). The DOE Richland Operations Office (DOE-RL), the EPA and Washington Department of Ecology (Ecology) issued the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), in May 1989 (Ecology et al. 1992, Rev. 2). This agreement, among other matters, governs all CERCLA efforts at the Hanford Site. In June 1990, a remedial investigation/feasibility study (RI/FS) workplan for the 300-FF-5 operable unit was issued pursuant to the Tri-Party Agreement.

  4. Phase 1 remedial investigation report for 200-BP-1 operable unit. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The US Department of Energy (DOE) Hanford Site, in Washington State is organized into numerically designated operational areas including the 100, 200, 300, 400, 600, and 1100 Areas. The US Environmental Protection Agency (EPA), in November 1989 included the 200 Areas of the Hanford Site on the National Priority List (NPL) under the Comprehensive Environmental Response, Compensation and Liability Act of 1980 (CERCLA). Inclusion on the NPL initiated the remedial investigation (RD process for the 200-BP-1 operable unit. These efforts are being addressed through the Hanford Federal Facility Agreement and Consent Order (Ecology et al. 1989) which was negotiated and approved by the DOE, the EPA, and the State of Washington Department of Ecology (Ecology) in May 1989. This agreement, known as the Tri-Party Agreement, governs all CERCLA efforts at Hanford. In March of 1990, the Department of Energy, Richland Operations (DOE-RL) issued a Remedial Investigation/Feasibility Study (RI/FS) work plan (DOE-RL 1990a) for the 200-BP-1 operable unit. The work plan initiated the first phase of site characterization activities associated with the 200-BP-1 operable unit. The purpose of the 200-BP-1 operable unit RI is to gather and develop the necessary information to adequately understand the risks to human health and the environment posed by the site and to support the development and analysis of remedial alternatives during the FS. The RI analysis will, in turn, be used by Tri-Party Agreement signatories to make a risk-management-based selection of remedies for the releases of hazardous substances that have occurred from the 200-BP-1 operable unit.

  5. Remedial investigation/feasibility study of the Clinch River/Poplar Creek operable unit. Volume 5

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This volume is in support of the findings of an investigation into contamination of the Clinch River and Poplar Creek near the Oak Ridge Reservation (for more than 50 years, various hazardous and radioactive substances have been released to the environment as a result of operations and waste management activities there). It addresses the quality assurance objectives for measuring the data, presents selected historical data, contains data from several discrete water characterization studies, provides data supporting the sediment characterization, and contains data related to several biota characterization studies.

  6. Evaluation of potential severe accidents during low power and shutdown operations at Surry: Unit 1, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.L.; Pratt, W.T. [eds.; Musicki, Z. [Brookhaven National Lab., Upton, NY (United States)

    1995-10-01

    This document contains a summarization of the results and insights from the Level 1 accident sequence analyses of internally initiated events, internally initiated fire and flood events, seismically initiated events, and the Level 2/3 risk analysis of internally initiated events (excluding fire and flood) for Surry, Unit 1. The analysis was confined to mid-loop operation, which can occur during three plant operational states (identified as POSs R6 and R10 during a refueling outage, and POS D6 during drained maintenance). The report summarizes the Level 1 information contained in Volumes 2--5 and the Level 2/3 information contained in Volume 6 of NUREG/CR-6144.

  7. Accomplishing Shipyard Work for the United States Navy: Institutions, Systems and Operations. Volume 3. Annotated Bibliography

    Science.gov (United States)

    1975-08-01

    operations research, advanced energy sources and propulsion technologies, nuclear physics, marine biology , maritime law, and ship financing. The...ductivity and reducing its production costs. 17 ()Determine whether -the industry c~ i achieve by FY 17 alevel of productivity that will allow reduction

  8. United States Air Force F-35A Operational Basing Environmental Impact Statement. Volume 1

    Science.gov (United States)

    2013-09-01

    15 nm offshore. Hill AFB, Utah – Situated near the Great Salt Lake and the UTTR, Hill AFB supports two operational squadrons of F-16s (48 aircraft...except over the Duck Valley Indian Reservation) and also allow flare use with seasonal and altitude restrictions. Supersonic flight is also authorized...possession, import, export, transport, selling, purchase, barter, or offering for sale purchase or barter, any migratory bird, their eggs , parts, and

  9. Operable Unit Boundaries

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset consists of operable unit data from multiple Superfund sites in U.S. EPA Region 8. These data were acquired from multiple sources at different times and...

  10. KC-46A Formal Training Unit (FTU) and First Main Operating Base (MOB 1) Beddown EIS. Volume 1

    Science.gov (United States)

    2014-03-01

    support a1rcraft operations and pHot and personnel training • ht UMI O~f’t EIS, the USAF ldet~titJ.s AltUS AF8 as the PTI~ fened A#etnAtfv• for liH! FTV...Frequency, commonly perceived as pitch, is the number of times per second the sound causes air molecules to oscillate . Frequency is measured in units of

  11. Operational waste volume projection

    Energy Technology Data Exchange (ETDEWEB)

    Koreski, G.M.

    1996-09-20

    Waste receipts to the double-shell tank system are analyzed and wastes through the year 2015 are projected based on generation trends of the past 12 months. A computer simulation of site operations is performed, which results in projections of tank fill schedules, tank transfers, evaporator operations, tank retrieval, and aging waste tank usage. This projection incorporates current budget planning and the clean-up schedule of the Tri-Party Agreement. Assumptions were current as of June 1996.

  12. Guadalcanal Operation. Volume 5

    Science.gov (United States)

    1943-07-01

    recurrent or relapsed, cases. ._•’• . - ; . MALARIA REPORT .FOR ,THE MONTH OF AUGUST Second Week Third Week " Fourth -Week- Total None 4 18 22...should be included in the original unit. Most of the dental officers would prefer brass orthodontic ligature wire in 18 inch eighteen inch stands to

  13. Remedial investigation/feasibility study of the Clinch River/Poplar Creek operable unit. Volume 1: Main text

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    This report presents the findings of an investigation into contamination of the Clinch River and Poplar Creek near the US Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) in eastern Tennessee. For more than 50 years, various hazardous and radioactive substances have been released to the environment as a result of operations and waste management activities at the ORR. In 1989, the ORR was placed on the National Priorities List (NPL), established and maintained under the federal Comprehensive environmental Response, Compensation, and Liability Act of 1980 (CERCLA). Under CERCLA, NPL sites must be investigated to determine the nature and extent of contamination at the site, assess the risk to human health and the environment posed by the site, and, if necessary, identify feasible remedial alternatives that could be used to clean the site and reduce risk. To facilitate the overall environmental restoration effort at the ORR, CERCLA activities are being implemented individually as distinct operable units (OUs). This document is the combined Remedial Investigation and Feasibility Study Report for the Clinch River/Poplar Creek OU.

  14. Remedial investigation/feasibility study for the Clinch River/Poplar Creek operable unit. Volume 3. Appendix E

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    This document contains Appendix E: Toxicity Information and Uncertainty Analysis, description of methods, from the combined Remedial Investigation/Feasibility Study Report for the Clinch River/Poplar Crack (CR/PC) Operable Unit (OU). The CR/PC OU is located in Anderson and Roane Counties, Tennessee and consists of the Clinch River and several of its embayments in Melton Hill and Watts Bar Reservoirs. These waters have received hazardous substances released over a period of 50 years from the US Department of Energy`s Oak Ridge Reservation (ORR), a National Priority List site established under the Comprehensive Environmental Response, Compensation, and Liability Act. A remedial investigation has been conducted to determine the current nature and extent of any contamination and to assess the resulting risk to human health and the environment. The feasibility study evaluates remedial action alternatives to identify any that are feasible for implementation and that would effectively reduce risk. Historical studies had indicated that current problems would likely include {sup 137}Cs in sediment of the Clinch River, mercury in sediment and fish of Poplar Creek and PCBs and pesticides in fish from throughout the OU. Peak releases of mercury and {sup 137}Cs occurred over 35 years ago, and current releases are low. Past releases of PCBs from the ORR are poorly quantified, and current releases are difficult to quantify because levels are so low. The site characterization focused on contaminants in surface water, sediment, and biota. Contaminants in surface water were all found to be below Ambient Water Quality Criteria. Other findings included the following: elevated metals including cesium 137 and mercury in McCoy Branch sediments; PCBs and chlordane elevated in several fish species, presenting the only major human health risk, significant ecological risks in Poplar Creek but not in the Clinch River.

  15. Remedial investigation/feasibility study of the Clinch River/Poplar Creek operable unit. Volume 1, main text

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This document is the combined Remedial Investigation/Feasibility Study (RI/FS) Report for the Clinch River/Poplar Creek Operable Unit (CR/PC OU), an off-site OU associated with environmental restoration activities at the U.S. Department of Energy (DOE) Oak Ridge Reservation (ORR). As a result of past, present, and potential future releases of hazardous substances into the environment, the ORR was placed on the National Priorities List in December 1989 (54 FR 48184). Sites on this list must be investigated for possible remedial action, as required by the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA, 42 U.S.C. 9601, et seq.). This report documents the findings of the remedial investigation of this OU and the feasibility of potential remedial action alternatives. These studies are authorized by Sect. 117 of CERCLA and were conducted in accordance with the requirements of the National Contingency Plan (40 CFR Part 300). DOE, the U.S. Environmental Protection Agency (EPA), and the Tennessee Department of Environment and Conservation (TDEC) have entered into a Federal Facility Agreement (FFA), as authorized by Sect. 120 of CERCLA and Sects. 3008(h) and 6001 of the Resource Conservation and Recovery Act (RCRA) (42 U.S.C. 6901, et seq.). The purpose of this agreement is to ensure a coordinated and effective response for all environmental restoration activities occurring at the ORR. In addition to other responsibilities, the FFA parties mutually define the OU boundaries, set remediation priorities, establish remedial investigation priorities and strategies, and identify and select remedial actions. A copy of this FFA is available from the DOE Information Resource Center in Oak Ridge, Tennessee.

  16. Remedial investigation/feasibility study for the Clinch River/Poplar Creek operable unit. Volume 1. Main text

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    This is the combined Remedial Investigation/Feasibility Study Report for the Clinch River/Poplar Crack (CR/PC) Operable Unit (OU). The CR/PC OU is located in Anderson and Roane Counties, Tennessee and consists of the Clinch River and several of its embayments in Melton Hill and Watts Bar Reservoirs. These waters have received hazardous substances released over a period of 50 years from the US Department of Energy`s Oak Ridge Reservation (ORR), a National Priority List site established under the Comprehensive Environmental Response, Compensation, and Liability Act. A remedial investigation has been conducted to determine the current nature and extent of any contamination and to assess the resulting risk to human health and the environment. The feasibility study evaluates remedial action alternatives to identify any that are feasible for implementation and that would effectively reduce risk. Historical studies had indicated that current problems would likely include {sup 137}Cs in sediment of the Clinch River, mercury in sediment and fish of Poplar Creek and PCBs and pesticides in fish from throughout the OU. Peak releases of mercury and {sup 137}Cs occurred over 35 years ago, and current releases are low. Past releases of PCBs from the ORR are poorly quantified, and current releases are difficult to quantify because levels are so low. The site characterization focused on contaminants in surface water, sediment, and biota. Contaminants in surface water were all found to be below Ambient Water Quality Criteria. Other findings included the following: elevated metals including cesium 137 and mercury in McCoy Branch sediments; PCBs and chlordane elevated in several fish species, presenting the only major human health risk, significant ecological risks in Poplar Creek but not in the Clinch River.

  17. Remedial investigation/feasibility study for the Clinch River/Poplar Creek operable unit. Volume 4. Appendix F

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    This section contains ecotoxicological profiles for the COPECs for the combined Remedial Investigation/Feasibility Study Report for the Clinch River/Poplar Crack (CR/PC) Operable Unit (OU). The ecotoxicological information is presented for only those endpoints for which the chemicals are COPECs. The CR/PC OU is located in Anderson and Roane Counties, Tennessee and consists of the Clinch River and several of its embayments in Melton Hill and Watts Bar Reservoirs. These waters have received hazardous substances released over a period of 50 years from the US Department of Energy`s Oak Ridge Reservation (ORR), a National Priority List site established under the Comprehensive Environmental Response, Compensation, and Liability Act. A remedial investigation has been conducted to determine the current nature and extent of any contamination and to assess the resulting risk to human health and the environment. The feasibility study evaluates remedial action alternatives to identify any that are feasible for implementation and that would effectively reduce risk. Historical studies had indicated that current problems would likely include {sup 137}Cs in sediment of the Clinch River, mercury in sediment and fish of Poplar Creek and PCBs and pesticides in fish from throughout the OU. Peak releases of mercury and {sup 137}Cs occurred over 35 years ago, and current releases are low. Past releases of PCBs from the ORR are poorly quantified, and current releases are difficult to quantify because levels are so low. The site characterization focused on contaminants in surface water, sediment, and biota. Contaminants in surface water were all found to be below Ambient Water Quality Criteria. Other findings included the following: elevated metals including cesium 137 and mercury in McCoy Branch sediments; PCBs and chlordane elevated in several fish species, presenting the only major human health risk, significant ecological risks in Poplar Creek but not in the Clinch River.

  18. MPCV Exercise Operational Volume Analysis

    Science.gov (United States)

    Godfrey, A.; Humphreys, B.; Funk, J.; Perusek, G.; Lewandowski, B. E.

    2017-01-01

    In order to minimize the loss of bone and muscle mass during spaceflight, the Multi-purpose Crew Vehicle (MPCV) will include an exercise device and enough free space within the cabin for astronauts to use the device effectively. The NASA Digital Astronaut Project (DAP) has been tasked with using computational modeling to aid in determining whether or not the available operational volume is sufficient for in-flight exercise.Motion capture data was acquired using a 12-camera Smart DX system (BTS Bioengineering, Brooklyn, NY), while exercisers performed 9 resistive exercises without volume restrictions in a 1g environment. Data were collected from two male subjects, one being in the 99th percentile of height and the other in the 50th percentile of height, using between 25 and 60 motion capture markers. Motion capture data was also recorded as a third subject, also near the 50th percentile in height, performed aerobic rowing during a parabolic flight. A motion capture system and algorithms developed previously and presented at last years HRP-IWS were utilized to collect and process the data from the parabolic flight [1]. These motions were applied to a scaled version of a biomechanical model within the biomechanical modeling software OpenSim [2], and the volume sweeps of the motions were visually assessed against an imported CAD model of the operational volume. Further numerical analysis was performed using Matlab (Mathworks, Natick, MA) and the OpenSim API. This analysis determined the location of every marker in space over the duration of the exercise motion, and the distance of each marker to the nearest surface of the volume. Containment of the exercise motions within the operational volume was determined on a per-exercise and per-subject basis. The orientation of the exerciser and the angle of the footplate were two important factors upon which containment was dependent. Regions where the exercise motion exceeds the bounds of the operational volume have been

  19. Remedial investigation/feasibility study of the Clinch River/Poplar Creek Operable Unit. Volume 3. Risk assessment information. Appendixes E, F

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This report presents the findings of an investigation into contamination of the Clinch River and Poplar Creek near the U.S. Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) in eastern Tennessee. For more than 50 years, various hazardous and radioactive substances have been released to the environment as a result of operations and waste management activities at the ORR. In 1989, the ORR was placed on the National Priorities List (NPL), established and maintained under the federal Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). Under CERCLA, NPL sites must be investigated to determine the nature and extent of contamination at the site, assess the risk to human health and the environment posed by the site, and, if necessary, identify feasible remedial alternatives that could be used to clean the site and reduce risk. To facilitate the overall environmental restoration effort at the ORR, CERCLA activities are being implemented individually as distinct operable units (OUs). This document is Volume 3 of the combined Remedial Investigation and Feasibility Study Report for the Clinch River/Poplar Creek OU.

  20. Remedial investigation/feasibility study of the Clinch River/Poplar Creek Operable Unit. Volume 5. Appendixes J, K, L, M, and N-other supporting information

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    This report presents the findings of an investigation into contamination of the Clinch River and Poplar Creek near the U.S. Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) in eastern Tennessee. For more than 50 years, various hazardous and radioactive substances have been released to the environment as a result of operations and waste management activities at the ORR. In 1989, the ORR was placed on the National Priorities List (NPL), established and maintained under the federal Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). Under CERCLA, NPL sites must be investigated to determine the nature and extent of contamination at the site, assess the risk to human health and the environment posed by the site, and, if necessary, identify feasible remedial alternatives that could be used to clean the site and reduce risk. To facilitate the overall environmental restoration effort at the ORR, CERCLA activities are being implemented individually as distinct operable units (OUs). This document is Volume 5 of the combined Remedial Investigation and Feasibility Study Report for the Clinch River/Poplar Creek OU.

  1. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Evaluation of severe accident risks for plant operational state 5 during a refueling outage. Main report and appendices, Volume 6, Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Brown, T.D.; Kmetyk, L.N.; Whitehead, D.; Miller, L. [Sandia National Labs., Albuquerque, NM (United States); Forester, J. [Science Applications International Corp., Albuquerque, NM (United States); Johnson, J. [GRAM, Inc., Albuquerque, NM (United States)

    1995-03-01

    Traditionally, probabilistic risk assessments (PRAS) of severe accidents in nuclear power plants have considered initiating events potentially occurring only during full power operation. Recent studies and operational experience have, however, implied that accidents during low power and shutdown could be significant contributors to risk. In response to this concern, in 1989 the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The program consists of two parallel projects being performed by Brookhaven National Laboratory (Surry) and Sandia National Laboratories (Grand Gulf). The program objectives include assessing the risks of severe accidents initiated during plant operational states other than full power operation and comparing the estimated risks with the risk associated with accidents initiated during full power operation as assessed in NUREG-1150. The scope of the program is that of a Level-3 PRA. The subject of this report is the PRA of the Grand Gulf Nuclear Station, Unit 1. The Grand Gulf plant utilizes a 3833 MWt BUR-6 boiling water reactor housed in a Mark III containment. The Grand Gulf plant is located near Port Gibson, Mississippi. The regime of shutdown analyzed in this study was plant operational state (POS) 5 during a refueling outage, which is approximately Cold Shutdown as defined by Grand Gulf Technical Specifications. The entire PRA of POS 5 is documented in a multi-volume NUREG report (NUREG/CR-6143). The internal events accident sequence analysis (Level 1) is documented in Volume 2. The Level 1 internal fire and internal flood analyses are documented in Vols 3 and 4, respectively.

  2. Small Unit Operations

    Science.gov (United States)

    2007-11-02

    best demonstrated value for small (< AA size) lithium - thionyl - chloride batteries (Halpert 1993). Equation (2-3) shows that the solar power...However, this energy den- sity this is only ~ 3 times larger than the demonstrated performance of the best lithium batteries , and the fuel cells are...Units 13 2.2.2 ASIC Capability 15 2.2.3 Power and Size 17 2.2.4 Cost 19 2.3 Power Sources 20 2.3.1 Batteries 21 2.3.2 Solar Augmentation

  3. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Summary of results. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Whitehead, D.W. [ed.; Staple, B.D.; Daniel, S.L. [and others

    1995-07-01

    During 1989 the Nuclear Regulatory Commission (NRC) initiated an extensive program to examine the potential risks during low power and shutdown operations. Two plants, Surry and Grand Gulf, were selected as the plants to be studied by Brookhaven National Laboratory (Surry) and Sandia National Laboratories (Grand Gulf). This report documents the work performed during the analysis of the Grand Gulf plant. A phased approach was used for the overall study. In Phase 1, the objectives were to identify potential vulnerable plant configurations, to characterize (on a high, medium, or low basis) the potential core damage accident scenario frequencies and risks, and to provide a foundation for a detailed Phase 2 analysis. It was in Phase 1 that the concept of plant operational states (POSs) was developed to allow the analysts to better represent the plant as it transitions from power operation to nonpower operation than was possible with the traditional technical specification divisions of modes of operation. This phase consisted of a coarse screening analysis performed for all POSs, including seismic and internal fire and flood for some POSs. In Phase 2, POS 5 (approximately cold shutdown as defined by Grand Gulf Technical Specifications) during a refueling outage was selected as the plant configuration to be analyzed based on the results of the Phase 1 study. The scope of the Level 1 study includes plant damage state analysis and uncertainty analysis and is documented in a multi-volume NUREG/CR report (i.e., NUREG/CR-6143). The internal events analysis is documented in Volume 2. Internal fire and internal flood analyses are documented in Volumes 3 and 4, respectively. A separate study on seismic analysis, documented in Volume 5, was performed for the NRC by Future Resources Associates, Inc. The Level 2/3 study of the traditional internal events is documented in Volume 6, and a summary of the results for all analyses is documented in Volume 1.

  4. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Evaluation of severe accident risks for plant operational state 5 during a refueling outage. Supporting MELCOR calculations, Volume 6, Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Kmetyk, L.N.; Brown, T.D. [Sandia National Labs., Albuquerque, NM (United States)

    1995-03-01

    To gain a better understanding of the risk significance of low power and shutdown modes of operation, the Office of Nuclear Regulatory Research at the NRC established programs to investigate the likelihood and severity of postulated accidents that could occur during low power and shutdown (LP&S) modes of operation at commercial nuclear power plants. To investigate the likelihood of severe core damage accidents during off power conditions, probabilistic risk assessments (PRAs) were performed for two nuclear plants: Unit 1 of the Grand Gulf Nuclear Station, which is a BWR-6 Mark III boiling water reactor (BWR), and Unit 1 of the Surry Power Station, which is a three-loop, subatmospheric, pressurized water reactor (PWR). The analysis of the BWR was conducted at Sandia National Laboratories while the analysis of the PWR was performed at Brookhaven National Laboratory. This multi-volume report presents and discusses the results of the BWR analysis. The subject of this part presents the deterministic code calculations, performed with the MELCOR code, that were used to support the development and quantification of the PRA models. The background for the work documented in this report is summarized, including how deterministic codes are used in PRAS, why the MELCOR code is used, what the capabilities and features of MELCOR are, and how the code has been used by others in the past. Brief descriptions of the Grand Gulf plant and its configuration during LP&S operation and of the MELCOR input model developed for the Grand Gulf plant in its LP&S configuration are given.

  5. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit-1: Analysis of core damage frequency from internal events during mid-loop operations. Appendices F-H, Volume 2, Part 4

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.L.; Musicki, Z.; Kohut, P.; Yang, J.; Bozoki, G.; Hsu, C.J.; Diamond, D.J. [Brookhaven National Lab., Upton, NY (United States); Bley, D.; Johnson, D. [PLG Inc., Newport Beach, CA (United States); Holmes, B. [AEA Technology, Dorset (United Kingdom)] [and others

    1994-06-01

    Traditionally, probabilistic risk assessments (PRA) of severe accidents in nuclear power plants have considered initiating events potentially occurring only during full power operation. Some previous screening analyses that were performed for other modes of operation suggested that risks during those modes were small relative to full power operation. However, more recent studies and operational experience have implied that accidents during low power and shutdown could be significant contributors to risk. Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The scope of the program includes that of a level-3 PRA. In phase 2, mid-loop operation was selected as the plant configuration to be analyzed based on the results of the phase 1 study. The objective of the phase 2 study is to perform a detailed analysis of the potential accident scenarios that may occur during mid-loop operation, and compare the results with those of NUREG-1150. The scope of the level-1 study includes plant damage state analysis, and uncertainty analysis. Volume 1 summarizes the results of the study. Internal events analysis is documented in Volume 2. It also contains an appendix that documents the part of the phase 1 study that has to do with POSs other than mid-loop operation. Internal fire and internal flood analyses are documented in Volumes 3 and 4. A separate study on seismic analysis, documented in Volume 5, was performed for the NRC by Future Resources Associates, Inc. Volume 6 documents the accident progression, source terms, and consequence analysis.

  6. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal events during mid-loop operations. Appendix E (Sections E.9-E.16), Volume 2, Part 3B

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.L.; Musicki, Z.; Kohut, P.; Yang, J.; Bozoki, G.; Hsu, C.J.; Diamond, D.J.; Wong, S.M. [Brookhaven National Lab., Upton, NY (United States); Bley, D.; Johnson, D. [PLG Inc., Newport Beach, CA (United States)] [and others

    1994-06-01

    Traditionally, probabilistic risk assessments (PRA) of severe accidents in nuclear power plants have considered initiating events potentially occurring only during full power operation. Some previous screening analyses that were performed for other modes of operation suggested that risks during those modes were small relative to full power operation. However, more recent studies and operational experience have implied that accidents during low power and shutdown could be significant contributors to risk. Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The scope of the program includes that of a level-3 PRA. In phase 2, mid-loop operation was selected as the plant configuration to be analyzed based on the results of the phase 1 study. The objective of the phase 2 study is to perform a detailed analysis of the potential accident scenarios that may occur during mid-loop operation, and compare the results with those of NUREG-1150. The scope of the level-1 study includes plant damage state analysis, and uncertainty analysis. Volume 1 summarizes the results of the study. Internal events analysis is documented in Volume 2. It also contains an appendix that documents the part of the phase 1 study that has to do with POSs other than mid-loop operation. Internal fire and internal flood analyses are documented in Volumes 3 and 4. A separate study on seismic analysis, documented in Volume 5, was performed for the NRC by Future Resources Associates, Inc. Volume 6 documents the accident progression, source terms, and consequence analysis.

  7. Remedial investigation/feasibility study of the Clinch River/Poplar Creek operable unit. Volume 3: Appendixes E and F -- Risk assessment information

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    This report presents the findings of an investigation into contamination of the Clinch River and Poplar Creek near the US Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) in eastern Tennessee. For more than 50 years, various hazardous and radioactive substances have been released to the environment as a result of operations and waste management activities at the ORR. In 1989, the ORR was placed on the National Priorities List (NPL), established and maintained under the federal Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). Under CERCLA, NPL sites must be investigated to determine the nature and extent of contamination at the site, assess the risk to human health and the environment posed by the site, and, if necessary, identify feasible remedial alternatives that could be used to clean the site and reduce risk. To facilitate the overall environmental restoration effort at the ORR, CERCLA activities are being implemented individually as distinct operable units (OUs). This document is the combined Remedial Investigation and Feasibility Study Report for the Clinch River/Poplar Creek OU.

  8. Remedial investigation/feasibility study of the Clinch River/Poplar Creek Operable Unit. Volume 2. Biota and representative concentrations of contaminants. Appendixes A, B, C, D

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This report presents the findings of an investigation into contamination of the Clinch River and Poplar Creek near the U.S. Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) in eastern Tennessee. For more than 50 years, various hazardous and radioactive substances have been released to the environment as a result of operations and waste management activities at the ORR. In 1989, the ORR was placed on the National Priorities List (NPL), established and maintained under the federal Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). Under CERCLA, NPL sites must be investigated to determine the nature and extent of contamination at the site, assess the risk to human health and the environment posed by the site, and, if necessary, identify feasible remedial alternatives that could be used to clean the site and reduce risk. To facilitate the overall environmental restoration effort at the ORR, CERCLA activities are being implemented individually as distinct operable units (OU`s). This document is the combined Remedial Investigation and Feasibility Study Report for the Clinch River/Poplar Creek OU.

  9. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Analysis of core damage frequency from internal events for Plant Operational State 5 during a refueling outage. Volume 2, Part 3: Internal Events Appendices I and J

    Energy Technology Data Exchange (ETDEWEB)

    Yakle, J. [Science Applications International Corp., Albuquerque, NM (United States); Darby, J. [Science and Engineering Associates, Inc., Albuquerque, NM (United States); Whitehead, D.; Staple, B. [Sandia National Labs., Albuquerque, NM (United States)

    1994-06-01

    This report provides supporting documentation for various tasks associated with the performance of the probablistic risk assessment for Plant Operational State 5 during a refueling outage at Grand Gulf, Unit 1 as documented in Volume 2, Part 1 of NUREG/CR-6143.

  10. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Evaluation of severe accident risk during mid-loop operations. Main report. Volume 6. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Jo, J.; Lin, C.C.; Neymotin, L. [Brookhaven National Lab., Upton, NY (United States)] [and others

    1995-05-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The scope of the program includes that of a level-3 PRA. A phased approach was used in the level-1 program. In phase 1 which was completed in Fall 1991, a coarse screening analysis including internal fire and flood was performed for all plant operational states (POSs). The objective of the phase 1 study was to identify potential vulnerable plant configurations, to characterize (on a high, medium, or low basis) the potential core damage accident scenarios, and to provide a foundation for a detailed phase 2 analysis. In phase 2, mid-loop operation was selected as the plant configuration to be analyzed based on the results of the phase 1 study. The objective of the phase 2 study is to perform a detailed analysis of the potential accident scenarios that may occur during mid-loop operation, and compare the results with those of NUREG-1150. The results of the phase 2 level 2/3 study are the subject of this volume of NUREG/CR-6144, Volume 6.

  11. Addendum to the remedial investigation report on Bear Creek Valley Operable Unit 2 (Rust Spoil Area, Spoil Area 1, and SY-200 Yard) at the Oak Ridge Y-12 Plant Oak Ridge, Tennessee. Volume 1: Main text

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    This addendum to the Remedial Investigation (RI) Report on Bear Creek Valley Operable Unit (OU) 2 at the Oak Ridge Y-12 Plant was prepared in accordance with requirements under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) for reporting the results of a site characterization for public review. This addendum is a supplement to a document that was previously issued in January 1995 and that provided the Environmental Restoration Program with information about the results of the 1993 investigation performed at OU 2. The January 1995 D2 version of the RI Report on Bear Creek Valley OU 2 included information on risk assessments that have evaluated impacts to human health and the environment. Information provided in the document formed the basis for the development of the Feasibility Study Report. This addendum includes revisions to four chapters of information that were a part of the document issued in January 1995. Specifically, it includes revisions to Chaps. 2, 3, 4, and 9. Volume 1 of this document is not being reissued in its entirety as a D3 version because only the four chapters just mentioned have been affected by requested changes. Note also that Volume 2 of this RI Report on Bear Creek Valley OU 2 is not being reissued in conjunction with Volume 1 of this document because there have been no changes requested or made to the previously issued version of Volume 2 of this document.

  12. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal events during mid-loop operations, Appendices A--D. Volume 2, Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.L.; Musicki, Z.; Kohut, P. [Brookhaven National Lab., Upton, NY (United States)] [and others

    1994-06-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the Potential risks during low Power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the Plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this report is to document the approach utilized in the Surry plant and discuss the results obtained. A parallel report for the Grand Gulf plant is prepared by SNL. This study shows that the core-damage frequency during mid-loop operation at the Surry plant is comparable to that of power operation. We recognize that there is very large uncertainty in the human error probabilities in this study. This study identified that only a few procedures are available for mitigating accidents that may occur during shutdown. Procedures written specifically for shutdown accidents would be useful. This document, Volume 2, Pt. 2 provides appendices A through D of this report.

  13. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit-1: Analysis of core damage frequency from internal events during mid-loop operations. Appendix I, Volume 2, Part 5

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.L.; Musicki, Z.; Kohut, P.; Yang, J.; Bozoki, G.; Hsu, C.J.; Diamond, D.J. [Brookhaven National Lab., Upton, NY (United States); Bley, D.; Johnson, D. [PLG Inc., Newport Beach, CA (United States); Holmes, B. [AEA Technology, Dorset (United Kingdom)] [and others

    1994-06-01

    Traditionally, probabilistic risk assessments (PRA) of severe accidents in nuclear power plants have considered initiating events potentially occurring only during full power operation. Some previous screening analyses that were performed for other modes of operation suggested that risks during those modes were small relative to full power operation. However, more recent studies and operational experience have implied that accidents during low power and shutdown could be significant contributors to risk. During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Lab. (BNL) and Sandia National Labs. (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this volume of the report is to document the approach utilized in the level-1 internal events PRA for the Surry plant, and discuss the results obtained. A phased approach was used in the level-1 program. In phase 1, which was completed in Fall 1991, a coarse screening analysis examining accidents initiated by internal events (including internal fire and flood) was performed for all plant operational states (POSs). The objective of the phase 1 study was to identify potential vulnerable plant configurations, to characterize (on a high, medium, or low basis) the potential core damage accident scenarios, and to provide a foundation for a detailed phase 2 analysis.

  14. Remedial investigation/feasibility study for the Clinch River/Poplar Creek operable unit. Volume 2. Appendixes A, B, C, D

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    This document contains appendices A (water characterization), B (sediment characterization), C (biota Characterization), D (applicable or relevant and appropriate requirements) from the combined Remedial Investigation/Feasibility Study Report for the Clinch River/Poplar Crack (CR/PC) Operable Unit (OU). The CR/PC OU is located in Anderson and Roane Counties, Tennessee and consists of the Clinch River and several of its embayments in Melton Hill and Watts Bar Reservoirs. These waters have received hazardous substances released over a period of 50 years from the US Department of Energy`s Oak Ridge Reservation (ORR), a National Priority List site established under the Comprehensive Environmental Response, Compensation, and Liability Act. A remedial investigation has been conducted to determine the current nature and extent of any contamination and to assess the resulting risk to human health and the environment. The feasibility study evaluates remedial action alternatives to identify any that are feasible for implementation and that would effectively reduce risk. Historical studies had indicated that current problems would likely include {sup 137}Cs in sediment of the Clinch River, mercury in sediment and fish of Poplar Creek and PCBs and pesticides in fish from throughout the OU. Peak releases of mercury and {sup 137}Cs occurred over 35 years ago, and current releases are low. Past releases of PCBs from the ORR are poorly quantified, and current releases are difficult to quantify because levels are so low. The site characterization focused on contaminants in surface water, sediment, and biota. Contaminants in surface water were all found to be below Ambient Water Quality Criteria. Other findings included the following: elevated metals including cesium 137 and mercury in McCoy Branch sediments; PCBs and chlordane elevated in several fish species, presenting the only major human health risk, significant ecological risks in Poplar Creek but not in the Clinch River.

  15. Finite volume renormalization scheme for fermionic operators

    Energy Technology Data Exchange (ETDEWEB)

    Monahan, Christopher; Orginos, Kostas [JLAB

    2013-11-01

    We propose a new finite volume renormalization scheme. Our scheme is based on the Gradient Flow applied to both fermion and gauge fields and, much like the Schr\\"odinger functional method, allows for a nonperturbative determination of the scale dependence of operators using a step-scaling approach. We give some preliminary results for the pseudo-scalar density in the quenched approximation.

  16. Installation Restoration Program (IRP) Stage 3. McClellan Air Force Base. Operable Unit B. Preliminary Assessment Summary Report. Volume 3. Appendices C, D & E

    Science.gov (United States)

    1991-10-01

    Types of materials handled: PCBs Acids Bases Radionucleides Specific chemicals handled: ammonium hydroxide hydrochloric acid nitric acid potassium...on the ground at PRL 30, which includes Building 631. Period of operation: 1960 to 1980 Types of materials handled: Radionucleides "Solvents Specific... radionucleides were handled or disposed. The following sites should be considered for radioactivity screening as part of future remedial investigations: o Site

  17. Unit Operations for the Food Industry: Equilibrium Processes & Mechanical Operations

    OpenAIRE

    Guiné, Raquel

    2013-01-01

    Unit operations are an area of engineering that is at the same time very fascinating and most essential for the industry in general and the food industry in particular. This book was prepared in a way to achieve simultaneously the academic and practical perspectives. It is organized into two parts: the unit operations based on equilibrium processes and the mechanical operations. Each topic starts with a presentation of the fundamental concepts and principles, followed by a discussion of ...

  18. Remedial investigation/feasibility study of the Clinch River/Poplar Creek Operable Unit. Volume 2. Appendixes A, B, C, and D-Biota and representative concentrations of contaminants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    This report presents the findings of an investigation into contamination of the Clinch River and Poplar Creek near the U.S. Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) in eastern Tennessee. For more than 50 years, various hazardous and radioactive substances have been released to the environment as a result of operations and waste management activities at the ORR. In 1989, the ORR was placed on the National Priorities List (NPL), established and maintained under the federal Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). Under CERCLA, NPL sites must be investigated to determine the nature and extent of contamination at the site, assess the risk to human health and the environment posed by the site, and, if necessary, identify feasible remedial alternatives that could be used to clean the site and reduce risk. To facilitate the overall environmental restoration effort at the ORR, CERCLA activities are being implemented individually as distinct operable units (OUs). This document is Volume 2 of the combined Remedial Investigation and Feasibility Study Report for the Clinch River/Poplar Creek OU.

  19. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1. Volume 5: Analysis of core damage frequency from seismic events for plant operational state 5 during a refueling outage

    Energy Technology Data Exchange (ETDEWEB)

    Budnitz, R.J. [Future Resources Associates, Inc., Berkeley, CA (United States); Davis, P.R. [PRD Consulting (United States); Ravindra, M.K.; Tong, W.H. [EQE International, Inc., Irvine, CA (United States)

    1994-08-01

    In 1989 the US Nuclear Regulatory Commission (NRC) initiated an extensive program to examine carefully the potential risks during low-power and shutdown operations. The program included two parallel projects, one at Sandia National Laboratories studying a boiling water reactor (Grand Gulf), and the other at Brookhaven National Laboratory studying a pressurized water reactor (Surry Unit 1). Both the Sandia and Brookhaven projects have examined only accidents initiated by internal plant faults---so-called ``internal initiators.`` This project, which has explored the likelihood of seismic-initiated core damage accidents during refueling outage conditions, is complementary to the internal-initiator analyses at Brookhaven and Sandia. This report covers the seismic analysis at Grand Gulf. All of the many systems modeling assumptions, component non-seismic failure rates, and human effort rates that were used in the internal-initiator study at Grand Gulf have been adopted here, so that the results of the study can be as comparable as possible. Both the Sandia study and this study examine only one shutdown plant operating state (POS) at Grand Gulf, namely POS 5 representing cold shutdown during a refueling outage. This analysis has been limited to work analogous to a level-1 seismic PRA, in which estimates have been developed for the core-damage frequency from seismic events during POS 5. The results of the analysis are that the core-damage frequency for earthquake-initiated accidents during refueling outages in POS 5 is found to be quite low in absolute terms, less than 10{sup {minus}7}/year.

  20. Mineral operations outside the United States

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Mineral facilities and operations outside the United States compiled by the National Minerals Information Center of the USGS. This representation combines source...

  1. Centrifugal microfluidic platforms: advanced unit operations and applications.

    Science.gov (United States)

    Strohmeier, O; Keller, M; Schwemmer, F; Zehnle, S; Mark, D; von Stetten, F; Zengerle, R; Paust, N

    2015-10-01

    Centrifugal microfluidics has evolved into a mature technology. Several major diagnostic companies either have products on the market or are currently evaluating centrifugal microfluidics for product development. The fields of application are widespread and include clinical chemistry, immunodiagnostics and protein analysis, cell handling, molecular diagnostics, as well as food, water, and soil analysis. Nevertheless, new fluidic functions and applications that expand the possibilities of centrifugal microfluidics are being introduced at a high pace. In this review, we first present an up-to-date comprehensive overview of centrifugal microfluidic unit operations. Then, we introduce the term "process chain" to review how these unit operations can be combined for the automation of laboratory workflows. Such aggregation of basic functionalities enables efficient fluidic design at a higher level of integration. Furthermore, we analyze how novel, ground-breaking unit operations may foster the integration of more complex applications. Among these are the storage of pneumatic energy to realize complex switching sequences or to pump liquids radially inward, as well as the complete pre-storage and release of reagents. In this context, centrifugal microfluidics provides major advantages over other microfluidic actuation principles: the pulse-free inertial liquid propulsion provided by centrifugal microfluidics allows for closed fluidic systems that are free of any interfaces to external pumps. Processed volumes are easily scalable from nanoliters to milliliters. Volume forces can be adjusted by rotation and thus, even for very small volumes, surface forces may easily be overcome in the centrifugal gravity field which enables the efficient separation of nanoliter volumes from channels, chambers or sensor matrixes as well as the removal of any disturbing bubbles. In summary, centrifugal microfluidics takes advantage of a comprehensive set of fluidic unit operations such as

  2. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal events during mid-loop operations, Appendices E (Sections E.1--E.8). Volume 2, Part 3A

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.L.; Musicki, Z.; Kohut, P. [Brookhaven National Lab., Upton, NY (United States)] [and others

    1994-06-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this report is to document the approach utilized in the Surry plant and discuss the results obtained. A parallel report for the Grand Gulf plant is prepared by SNL. This study shows that the core-damage frequency during mid-loop operation at the Surry plant is comparable to that of power operation. The authors recognize that there is very large uncertainty in the human error probabilities in this study. This study identified that only a few procedures are available for mitigating accidents that may occur during shutdown. Procedures written specifically for shutdown accidents would be useful.

  3. Unpacking Referent Units in Fraction Operations

    Science.gov (United States)

    Philipp, Randolph A.; Hawthorne, Casey

    2015-01-01

    Although fraction operations are procedurally straightforward, they are complex, because they require learners to conceptualize different units and view quantities in multiple ways. Prospective secondary school teachers sometimes provide an algebraic explanation for inverting and multiplying when dividing fractions. That authors of this article…

  4. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal floods during mid-loop operations. Volume 4

    Energy Technology Data Exchange (ETDEWEB)

    Kohut, P. [Brookhaven National Lab., Upton, NY (United States)

    1994-07-01

    The major objective of the Surry internal flood analysis was to provide an improved understanding of the core damage scenarios arising from internal flood-related events. The mean core damage frequency of the Surry plant due to internal flood events during mid-loop operations is 4.8E-06 per year, and the 5th and 95th percentiles are 2.2E-07 and 1.8E-05 per year, respectively. Some limited sensitivity calculations were performed on three plant improvement options. The most significant result involves modifications of intake-level structure on the canal, which reduced core damage frequency contribution from floods in mid-loop by about 75%.

  5. Produced water volumes and management practices in the United States.

    Energy Technology Data Exchange (ETDEWEB)

    Clark, C. E.; Veil, J. A. (Environmental Science Division)

    2009-09-01

    Produced water volume generation and management in the United States are not well characterized at a national level. The U.S. Department of Energy (DOE) asked Argonne National Laboratory to compile data on produced water associated with oil and gas production to better understand the production volumes and management of this water. The purpose of this report is to improve understanding of produced water by providing detailed information on the volume of produced water generated in the United States and the ways in which produced water is disposed or reused. As the demand for fresh water resources increases, with no concomitant increase in surface or ground water supplies, alternate water sources, like produced water, may play an important role. Produced water is water from underground formations that is brought to the surface during oil or gas production. Because the water has been in contact with hydrocarbon-bearing formations, it contains some of the chemical characteristics of the formations and the hydrocarbons. It may include water from the reservoir, water previously injected into the formation, and any chemicals added during the production processes. The physical and chemical properties of produced water vary considerably depending on the geographic location of the field, the geologic formation, and the type of hydrocarbon product being produced. Produced water properties and volume also vary throughout the lifetime of a reservoir. Produced water is the largest volume by-product or waste stream associated with oil and gas exploration and production. Previous national produced water volume estimates are in the range of 15 to 20 billion barrels (bbl; 1 bbl = 42 U.S. gallons) generated each year in the United States (API 1988, 2000; Veil et al. 2004). However, the details on generation and management of produced water are not well understood on a national scale. Argonne National Laboratory developed detailed national-level information on the volume of produced

  6. The United States Military and Humanitarian Operations

    Science.gov (United States)

    1995-01-01

    stated that, "The wave of the future will be putting together task forces that will be able to respond to crisis management or humanitarian...examine three options for the military’s role in humanitaria operations at home and abroad. Option 1: Virtually Eliminate Anv Military Role This is the...humanitarian aid in almost any crisis .36 The military resists the creation of specially designated units because such specialization reduces the

  7. Research on Canal System Operation Based on Controlled Volume Method

    Directory of Open Access Journals (Sweden)

    Zhiliang Ding

    2009-10-01

    Full Text Available An operating simulation mode based on storage volume control method for multireach canal system in series was established. In allusion to the deficiency of existing controlled volume algorithm, the improved algorithm was proposed, that is the controlled volume algorithm of whole canal pools, the simulation results indicate that the storage volume and water level of each canal pool can be accurately controlled after the improved algorithm was adopted. However, for some typical discharge demand change operating conditions of canal, if the controlled volume algorithm of whole canal pool is still adopted, then it certainly will cause some unnecessary regulation, and consequently increases the disturbed canal reaches. Therefor, the idea of controlled volume operation method of continuous canal pools was proposed, and its algorithm was designed. Through simulation to practical project, the results indicate that the new controlled volume algorithm proposed for typical operating condition can comparatively obviously reduce the number of regulated check gates and disturbed canal pools for some typical discharge demand change operating conditions of canal, thus the control efficiency of canal system was improved. The controlled volume method of operation is specially suitable for large-scale water delivery canal system which possesses complex operation requirements.

  8. Generalized functions, volume 1 properties and operations

    CERN Document Server

    Gel′fand, I M

    2016-01-01

    The first systematic theory of generalized functions (also known as distributions) was created in the early 1950s, although some aspects were developed much earlier, most notably in the definition of the Green's function in mathematics and in the work of Paul Dirac on quantum electrodynamics in physics. The six-volume collection, Generalized Functions, written by I. M. Gel′fand and co-authors and published in Russian between 1958 and 1966, gives an introduction to generalized functions and presents various applications to analysis, PDE, stochastic processes, and representation theory. Volume 1

  9. NIC atomic operation unit with caching and bandwidth mitigation

    Science.gov (United States)

    Hemmert, Karl Scott; Underwood, Keith D.; Levenhagen, Michael J.

    2016-03-01

    A network interface controller atomic operation unit and a network interface control method comprising, in an atomic operation unit of a network interface controller, using a write-through cache and employing a rate-limiting functional unit.

  10. An operator calculus for surface and volume modeling

    Science.gov (United States)

    Gordon, W. J.

    1984-01-01

    The mathematical techniques which form the foundation for most of the surface and volume modeling techniques used in practice are briefly described. An outline of what may be termed an operator calculus for the approximation and interpolation of functions of more than one independent variable is presented. By considering the linear operators associated with bivariate and multivariate interpolation/approximation schemes, it is shown how they can be compounded by operator multiplication and Boolean addition to obtain a distributive lattice of approximation operators. It is then demonstrated via specific examples how this operator calculus leads to practical techniques for sculptured surface and volume modeling.

  11. Remedial investigation report on Bear Creek Valley Operable Unit 2 (rust spoil area, spoil area 1, and SY-200 yard) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Volume 2. Appendixes

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    This document contains the appendices to the Remedial Investigation Report on Bear Creek Valley Operable Unit 2 (Rust Spoil Area, Spoil Area 1, and SY-200 Yard) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. The appendices include Current and historical soil boring and groundwater monitoring well information, well construction logs, and field change orders; Analytical data; Human health risk assessment data; and Data quality.

  12. Remedial investigation report on Chestnut Ridge Operable Unit 2 (filled coal ash pond/Upper McCoy Branch) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Volume 2: Appendixes

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    This report comprises appendices A--J which support the Y-12 Plant`s remedial action report involving Chestnut Ridge Operable Unit 2 (filled coal ash pond/Upper McCoy Branch). The appendices cover the following: Sampling fish from McCoy Branch; well and piezometer logs; ecological effects of contaminants in McCoy Branch 1989-1990; heavy metal bioaccumulation data; microbes in polluted sediments; and baseline human health risk assessment data.

  13. 21 CFR 872.6640 - Dental operative unit and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...

  14. Data collection system. Volume 1, Overview and operators manual; Volume 2, Maintenance manual; Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, R.B.; Bauder, M.E.; Boyer, W.B.; French, R.E.; Isidoro, R.J.; Kaestner, P.C.; Perkins, W.G.

    1993-09-01

    Sandia National Laboratories (SNL) Instrumentation Development Department was tasked by the Defense Nuclear Agency (DNA) to record data on Tektronix RTD720 Digitizers on the HUNTERS TROPHY field test conducted at the Nevada Test Site (NTS) on September 18, 1992. This report contains a overview and description of the computer hardware and software that was used to acquire, reduce, and display the data. The document is divided into two volumes: an overview and operators manual (Volume 1) and a maintenance manual (Volume 2).

  15. SET OPERATOR-BASED METHOD OF DENOISING MEDICAL VOLUME DATA

    Institute of Scientific and Technical Information of China (English)

    程兵; 郑南宁; 袁泽剑

    2002-01-01

    Objective To investigate impulsive noise suppression of medical volume data. Methods The volume data is represented as level sets and a special set operator is defined and applied to filtering it. The small connected components, which are likely to be produced by impulsive noise, are eliminated after the filtering process. A fast algorithm that uses a heap data structure is also designed. Results Compared with traditional linear filters such as a Gaussian filter, this method preserves the fine structure features of the medical volume data while removing noise, and the fast algorithm developed by us reduces memory consumption and improves computing efficiency. The experimental results given illustrate the efficiency of the method and the fast algorithm. Conclusion The set operator-based method shows outstanding denoising properties in our experiment, especially for impulsive noise. The method has a wide variety of applications in the areas of volume visualization and high dimensional data processing.

  16. 200-BP-5 operable unit treatability test report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    The 200-BP-5 Operable Unit was established in response to recommendations presented in the 200 East Groundwater Aggregate Area Management Study Report (AAMSR) (DOE-RL 1993a). Recognizing different approaches to remediation, the groundwater AAMSR recommended separating groundwater from source and vadose zone operable units and subdividing 200 East Area groundwater into two operable units. The division between the 200-BP-5 and 200-PO-1 Operable Units was based principally on source operable unit boundaries and distribution of groundwater plumes derived from either B Plant or Plutonium/Uranium Extraction (PUREX) Plant liquid waste disposal sites.

  17. Guide to the selection, training, and licensing or certification of reprocessing plant operators. Volume I

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-06-01

    The Code of Federal Regulations, Title 10, Part 55, establishes procedures and criteria for the licensing of operators, including senior operators, in ''Production and Utilization Facilities'', which includes plants for reprocessing irradiated fuel. A training guide is presented which will facilitate the licensing of operators for nuclear reprocessing plants by offering generalized descriptions of the basic principles (theory) and the unit operations (mechanics) employed in reprocessing spent fuels. In the present volume, details about the portions of a training program that are of major interest to management are presented. (JSR)

  18. Graphical calculus of volume, inverse volume and Hamiltonian operators in loop quantum gravity

    Science.gov (United States)

    Yang, Jinsong; Ma, Yongge

    2017-04-01

    To adopt a practical method to calculate the action of geometrical operators on quantum states is a crucial task in loop quantum gravity. In this paper, the graphical calculus based on the original Brink graphical method is applied to loop quantum gravity along the line of previous work. The graphical method provides a very powerful technique for simplifying complicated calculations. The closed formula of the volume operator and the actions of the Euclidean Hamiltonian constraint operator and the so-called inverse volume operator on spin-network states with trivalent vertices are derived via the graphical method. By employing suitable and non-ambiguous graphs to represent the action of operators as well as the spin-network states, we use the simple rules of transforming graphs to obtain the resulting formula. Comparing with the complicated algebraic derivation in some literature, our procedure is more concise, intuitive and visual. The resulting matrix elements of the volume operator is compact and uniform, fitting for both gauge-invariant and gauge-variant spin-network states. Our results indicate some corrections to the existing results for the Hamiltonian operator and inverse volume operator in the literature.

  19. Graphical calculus of volume, inverse volume and Hamiltonian operators in loop quantum gravity

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jinsong [Guizhou University, Department of Physics, Guiyang (China); Academia Sinica, Institute of Physics, Taipei (China); Ma, Yongge [Beijing Normal University, Department of Physics, Beijing (China)

    2017-04-15

    To adopt a practical method to calculate the action of geometrical operators on quantum states is a crucial task in loop quantum gravity. In this paper, the graphical calculus based on the original Brink graphical method is applied to loop quantum gravity along the line of previous work. The graphical method provides a very powerful technique for simplifying complicated calculations. The closed formula of the volume operator and the actions of the Euclidean Hamiltonian constraint operator and the so-called inverse volume operator on spin-network states with trivalent vertices are derived via the graphical method. By employing suitable and non-ambiguous graphs to represent the action of operators as well as the spin-network states, we use the simple rules of transforming graphs to obtain the resulting formula. Comparing with the complicated algebraic derivation in some literature, our procedure is more concise, intuitive and visual. The resulting matrix elements of the volume operator is compact and uniform, fitting for both gauge-invariant and gauge-variant spin-network states. Our results indicate some corrections to the existing results for the Hamiltonian operator and inverse volume operator in the literature. (orig.)

  20. Accelerating the Fourier split operator method via graphics processing units

    CERN Document Server

    Bauke, Heiko

    2010-01-01

    Current generations of graphics processing units have turned into highly parallel devices with general computing capabilities. Thus, graphics processing units may be utilized, for example, to solve time dependent partial differential equations by the Fourier split operator method. In this contribution, we demonstrate that graphics processing units are capable to calculate fast Fourier transforms much more efficiently than traditional central processing units. Thus, graphics processing units render efficient implementations of the Fourier split operator method possible. Performance gains of more than an order of magnitude as compared to implementations for traditional central processing units are reached in the solution of the time dependent Schr\\"odinger equation and the time dependent Dirac equation.

  1. UNITED STATES SPECIAL OPERATIONS FORCES IN AFRICA

    Science.gov (United States)

    2016-02-16

    and Nathan Rickard ,”Operation Serval: French Intervention in Mali,” Air Operations Division, Defence Science & Technology Organisation, http...www.cfr.org/nigeria/boko-haram/p25739. 56 James J. F. Forest, Confronting the Terrorism of Boko Haram in Nigeria, Joint Special Operations University...Best Practices.” Joint Forces Quarterly, Issue 50, 3d Quarter 2008. 30 Forest, James J. F. Confronting the Terrorism of Boko Haram in

  2. Remedial Investigation Report on Chestnut Ridge Operable Unit 2 (Filled Coal Ash Pond/Upper McCoy Branch) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Volume 1. Main Text

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    This document is a report on the remedial investigation (RI) of Chestnut Ridge Operable Unit (OU) 2 at the Oak Ridge Y-12 Plant. Chestnut Ridge OU 2 consists of Upper McCoy Branch (UMB), the Filled Coal Ash Pond (FCAP), and the area surrounding the Sluice Channel formerly associated with coal ash disposal in the FCAP. Chestnut Ridge OU 2 is located within the U.S. Department of Energy`s (DOE`s) Oak Ridge Reservation in Anderson County, Tennessee, approximately 24 miles west of Knoxville. The pond is an 8.5-acre area on the southern slope of Chestnut Ridge, 0.5 mile south of the main Y-12 Plant and geographically separated from the Y-12 Plant by Chestnut Ridge. The elevation of the FCAP is {approximately} 950 ft above mean sea level (msl), and it is relatively flat and largely vegetated. Two small ponds are usually present at the northeast and northwest comers of the FCAP. The Sluice Channel Area extends {approximately}1000 ft from the northern margin of the FCAP to the crest of Chestnut Ridge, which has an elevation of {approximately}1100 ft above msl. The Sluice Channel Area is largely vegetated also. McCoy Branch runs from the top of Chestnut Ridge across the FCAP into Rogers Quarry and out of the quarry where it runs a short distance into Milton Hill Lake at McCoy Embayment, termed UMB. The portion south of Rogers Quarry, within Chestnut Ridge OU 4, is termed Lower McCoy Branch. The DOE Oak Ridge Y-12 Plant disposed of coal ash from its steam plant operations as a slurry that was discharged into an ash retention impoundment; this impoundment is the FCAP. The FCAP was built in 1955 to serve as a settling basin after coal ash slurried over Chestnut Ridge from the Y-12 Plant. The FCAP was constructed by building an earthen dam across the northern tributary of McCoy Branch. The dam was designed to hold 20 years of Y-12 steam plant ash. By July 1967, ash had filled up the impoundment storage behind the dam to within 4 ft of the top.

  3. Hanford tank waste operation simulator operational waste volume projection verification and validation procedure

    Energy Technology Data Exchange (ETDEWEB)

    HARMSEN, R.W.

    1999-10-28

    The Hanford Tank Waste Operation Simulator is tested to determine if it can replace the FORTRAN-based Operational Waste Volume Projection computer simulation that has traditionally served to project double-shell tank utilization. Three Test Cases are used to compare the results of the two simulators; one incorporates the cleanup schedule of the Tri Party Agreement.

  4. Analysis on Operation Reliability of Generating Units in 2009

    Institute of Scientific and Technical Information of China (English)

    Zhou

    2010-01-01

    This paper presents the data on operation reliability indices and relevant analyses toward China's conventional power generating units in 2009. The units brought into the statistical analysis include 100-MW or above thermal generating units, 40-MW or above hydro generating units, and all nuclear generating units. The reliability indices embodied include utilization hours, times and hours of scheduled outages, times and hours of unscheduled outages, equivalent forced outage rate and equivalent availability factor.

  5. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1. Volume 2, Part 1C: Analysis of core damage frequency from internal events for plant operational State 5 during a refueling outage, Main report (Sections 11--14)

    Energy Technology Data Exchange (ETDEWEB)

    Whitehead, D. [Sandia National Labs., Albuquerque, NM (United States); Darby, J. [Science and Engineering Associates, Inc., Albuquerque, NM (United States); Yakle, J. [Science Applications International Corp., Albuquerque, NM (United States)] [and others

    1994-06-01

    This document contains the accident sequence analysis of internally initiated events for Grand Gulf, Unit 1 as it operates in the Low Power and Shutdown Plant Operational State 5 during a refueling outage. The report documents the methodology used during the analysis, describes the results from the application of the methodology, and compares the results with the results from two full power analyses performed on Grand Gulf.

  6. Determination of volumes in pipeline drain operation; Determinacao de volumes em operacao de drenagem de oleodutos

    Energy Technology Data Exchange (ETDEWEB)

    Pires, Luis Fernando G.; Barreto, Claudio V.; Silva, Bruno G. de [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica. Nucleo de Simulacao Termohidraulica de Dutos - SIMDUT

    2005-07-01

    Usually, pipeline and equipment maintenance requires the partial or fully drainage of the line. To develop this operation, it is necessary to preview the volumes at the drainage points to allocate the available resources to remove the liquid. With this main objective it was developed a numerical tool that is able to calculate the drainage volumes using only the data source from the GIS profile. This is possible if we consider a pipeline at no-flow state where only the gravitational forces can act in the fluid. The present paper uses a spreadsheet to determine the product volumes based in the drain points sequence and considering no flow boundaries along the pipeline. To validate the methodology a comparison is done with the results acquired in two real state drainage operations. (author)

  7. User's operating procedures. Volume 2: Scout project financial analysis program

    Science.gov (United States)

    Harris, C. G.; Haris, D. K.

    1985-01-01

    A review is presented of the user's operating procedures for the Scout Project Automatic Data system, called SPADS. SPADS is the result of the past seven years of software development on a Prime mini-computer located at the Scout Project Office, NASA Langley Research Center, Hampton, Virginia. SPADS was developed as a single entry, multiple cross-reference data management and information retrieval system for the automation of Project office tasks, including engineering, financial, managerial, and clerical support. This volume, two (2) of three (3), provides the instructions to operate the Scout Project Financial Analysis program in data retrieval and file maintenance via the user friendly menu drivers.

  8. Integrated Ground Operations Demonstration Units Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall goal of the project is to demonstrate cost efficient cryogenic operations on a relevant scale that can be projected onto future Spaceport architectures...

  9. No Correlation Between Work-Hours and Operative Volumes

    DEFF Research Database (Denmark)

    Kjærgaard, Jane; Sillesen, Martin; Beier-Holgersen, Randi

    2016-01-01

    OBJECTIVE: Since 2003, United States residents have been limited to an 80-hour workweek. This has prompted concerns of reduced educational quality, especially inadequate operating exposure. In contrast, the Danish surgical specialty-training program mandates a cap on working hours of 37 per week....

  10. Analysis of Serbian Military Riverine Units Capability for Participation in the United Nations Peacekeeping Operations

    Directory of Open Access Journals (Sweden)

    Slobodan Radojevic

    2017-06-01

    Full Text Available This paper analyses required personnel, training capacities and equipment for participation in the United Nations peacekeeping operations with the riverine elements. In order to meet necessary capabilities for engagement in United Nations peacekeeping operations, Serbian military riverine units have to be compatible with the issued UN requirements. Serbian Armed Forces have the potential to reach such requirements with the River Flotilla as a pivot for the participation in UN missions. Serbian Military Academy adopted and developed educational and training program in accordance with the provisions and recommendations of the IMO conventions and IMO model courses. Serbian Military Academy has opportunities for education and training military riverine units for participation in the United Nations peacekeeping operations. Moreover, Serbia has Multinational Operations Training Center and Peacekeeping Operations Center certified to provide selection, training, equipping and preparations of individuals and units to the United Nations multinational operations.

  11. Ground Operations Aerospace Language (GOAL). Volume 3: Data bank

    Science.gov (United States)

    1973-01-01

    The GOAL (Ground Operations Aerospace Language) test programming language was developed for use in ground checkout operations in a space vehicle launch environment. To insure compatibility with a maximum number of applications, a systematic and error-free method of referencing command/response (analog and digital) hardware measurements is a principle feature of the language. Central to the concept of requiring the test language to be independent of launch complex equipment and terminology is that of addressing measurements via symbolic names that have meaning directly in the hardware units being tested. To form the link from test program through test system interfaces to the units being tested the concept of a data bank has been introduced. The data bank is actually a large cross-reference table that provides pertinent hardware data such as interface unit addresses, data bus routings, or any other system values required to locate and access measurements.

  12. Military Implications of United Nations Peacekeeping Operations

    Science.gov (United States)

    1993-06-01

    maintenance of law and order, protecting the delivery of humanitarian assistance, the denial of an air space and the guarantee of rights of passage . In...involve the coordinated presence of warships and combat aircraft in the disputed region. Operations to guarantee rights of passage may be mounted to ensure

  13. Laboratory Evaluation of In Situ Chemical Oxidation for Groundwater Remediation, Test Area North, Operable Unit 1-07B, Idaho National Engineering and Environmental Laboratory, Volume Three - Appendix F

    Energy Technology Data Exchange (ETDEWEB)

    Cline, S.R.; Denton, D.L.; Giaquinto, J.M.; McCracken, M.K.; Starr, R.C.

    1999-04-01

    This appendix supports the results and discussion of the laboratory work performed to evaluate the feasibility of in situ chemical oxidation for Idaho National Environmental and Engineering Laboratory's (INEEL) Test Area North (TAN) which is contained in ORNL/TM-13711/V1. This volume contains Appendix F. Appendix F is essentially a photocopy of the ORNL researchers' laboratory notebooks from the Environmental Sciences Division (ESD) and the Radioactive Materials Analytical Laboratory (RMAL).

  14. Study on safety operation for large hydroelectric generator unit

    Science.gov (United States)

    Yan, Z. G.; Cui, T.; Zhou, L. J.; Zhi, F. L.; Wang, Z. W.

    2012-11-01

    Hydroelectric generator unit is a complex mechanical system which is composed of hydraulic turbine and electric generator. Rotary system is supported by the bearing bracket and the reinforced concrete structures, and vibration problem can't be avoided in the process of operating. Many large-scale hydroelectric units have been damaged because of the vibration problem in recent years. As the increase of the hydraulic turbine unit capacity and water head, the safe operation of hydraulic turbine has become a focus research in many countries. The operating characteristics of the hydraulic turbine have obvious differences at different working conditions. Based on the combination of field measurement and theoretical calculation, this paper shows a deep research on the safe operation of a large-scale Francis turbine unit. Firstly, the measurements of vibration, swing, pressure fluctuation and noise were carried out at 4 different heads. And also the relationships between vibrations and pressure fluctuations at different heads and working conditions were analysed deeply. Then the scientific prediction of safe operation for the unit at high head were done based on the CFD numerical calculation. Finally, this paper shows the division of the operating zone for the hydroelectric unit. According to the experimental results (vibrations, swings, pressure fluctuations and noise) as well as the theoretical results, the operating zone of the unit has been divided into three sections: prohibited operating zone, transition operating zone and safe operating zone. After this research was applied in the hydropower station, the security and economic efficiency of unit increased greatly, and enormous economic benefits and social benefits have been obtained.

  15. Utility FGD survey, January--December 1989. Volume 2, Design performance data for operating FGD systems: Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Hance, S.L.; McKibben, R.S.; Jones, F.M. [IT Corp., Cincinnati, OH (United States)

    1992-03-01

    This is Volume 2 part 2, of the Utility flue gas desulfurization (FGD) Survey report, which is generated by a computerized data base management system, represents a survey of operational and planned domestic utility flue gas desulfurization (FGD) systems. It summarizes information contributed by the utility industry, system and equipment suppliers, system designers, research organizations, and regulatory agencies. The data cover system design, fuel characteristics, operating history, and actual system performance. Also included is a unit-by-unit discussion of problems and solutions associated with the boilers, scrubbers, and FGD systems. This volume particularly contains basic design and performance data.

  16. Security-constrained unit commitment with flexible operating modes

    Science.gov (United States)

    Lu, Bo

    The electricity industry throughout the world, which has long been dominated by vertically integrated utilities, is facing enormous challenges. To enhance the competition in electricity industry, vertically integrated utilities are evolving into a distributed and competitive industry in which market forces drive the price of electricity and possibly reduce the net cost of supplying electrical loads through increased competition. To excel in the competition, generation companies (GENCOs) will acquire additional generating units with flexible operating capability which allows a timely response to the continuous changes in power system conditions. This dissertation considers the short-term scheduling of generating units with flexible modes of operation in security-constrained unit commitment (SCUC). Among the units considered in this study are combined cycle units, fuel switching/blending units, photovoltaic/battery system, pumped-storage units, and cascaded hydro units. The proposed security-constrained unit commitment solution will include a detailed model of transmission system which could impact the short-term scheduling of units with flexible operation modes.

  17. Sand and Gravel Operations in the United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer includes sand and gravel operations in the United States. These data were obtained from information reported voluntarily to the USGS by the aggregate...

  18. Crushed Stone Operations in the United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer includes crushed stone operations in the United States. These data were obtained from information reported voluntarily to the USGS by the aggregate...

  19. Laboratory Evaluation of In Situ Chemical Oxidation for Groundwater Remediation, Test Area North, Operable Unit 1-07B, Idaho National Engineering and Environmental Laboratory, Volume Two, Appendices C, D, and E

    Energy Technology Data Exchange (ETDEWEB)

    Cline, S.R.; Denton, D.L.; Giaquinto, J.M.; McCracken, M.K.; Starr, R.C.

    1999-04-01

    These appendices support the results and discussion of the laboratory work performed to evaluate the feasibility of in situ chemical oxidation for Idaho National Environmental and Engineering Laboratory's (INEEL) Test Area North (TAN) which is contained in ORNL/TM-1371 l/Vol. This volume contains Appendices C-E. Appendix C is a compilation of all recorded data and mathematical calculations made to interpret the data. For the Task 3 and Task 4 work, the spreadsheet column definitions are included immediately before the actual spreadsheet pages and are listed as ''Sample Calculations/Column Definitions'' in the table of contents. Appendix D includes the chronological order in which the experiments were conducted and the final project costs through October 1998. Appendix E is a compilation of the monthly progress reports submitted to INEEL during the course of the project.

  20. Eielson Air Force Base Operable Unit 2 baseline risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, R.E.; Jarvis, T.T.; Jarvis, M.R.; Whelan, G.

    1994-10-01

    Operable Unit 2 at Eielson Air Force Base (AFB) near Fairbanks, is one of several operable units characterized by petroleum, oil, and lubricant contamination, and by the presence of organic products floating at the water table, as a result of Air Force operations since the 1940s. The base is approximately 19,270 acres in size, and comprises the areas for military operations and a residential neighborhood for military dependents. Within Operable Unit 2, there are seven source areas. These source areas were grouped together primarily because of the contaminants released and hence are not necessarily in geographical proximity. Source area ST10 includes a surface water body (Hardfill Lake) next to a fuel spill area. The primary constituents of concern for human health include benzene, toluene, ethylbenzene, and xylenes (BTEX). Monitored data showed these volatile constituents to be present in groundwater wells. The data also showed an elevated level of trace metals in groundwater.

  1. Impact of varied center volume categories on volume-outcome relationship in children receiving ECMO for heart operations.

    Science.gov (United States)

    Rettiganti, Mallikarjuna; Seib, Paul M; Robertson, Michael J; Wilcox, Andrew; Gupta, Punkaj

    2016-09-01

    To study the volume-outcome relationship among children receiving extracorporeal membrane oxygenation (ECMO), different studies from different databases use different volume categories. The objective of this study was to evaluate if different center volume categories impact the volume-outcome relationship among children receiving ECMO for heart operations. We performed a post hoc analysis of data from an existing national database, the Pediatric Health Information System. Centers were classified into five different volume categories using different cut-offs and different variables. Mortality rates were compared between the varied volume categories using a mixed effects logistic regression model after adjusting for patient- and center-level risk factors. Data collection included demographic information, baseline characteristics, pre-ECMO risk factors, operation details, patient diagnoses, and center data. In unadjusted analysis, there was a significant relationship between center volume and mortality, with low-and medium-volume centers associated with higher mortality rates compared to high-volume centers in all volume categories, except the hierarchical clustering volume category. In contrast, there was no significant association between center-volume and mortality among all volume categories in adjusted analysis. We concluded that high-volume centers were not associated with improved outcomes for the majority of the categorization schemes despite using different cut-offs and different variables for volume categorization.

  2. Feasibility study report for the 200-BP-1 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    1993-06-01

    This feasibility study examines a range of alternatives and provides recommendations for selecting a preferred alternative for remediating contamination at the 200-BP-1 operable unit. The 200-BP-1 operable unit is located in the center of the Hanford Site along the northern boundary of the 200 East Area. The 241-BY Tank Farm is located immediately to the south of the operable unit. 200-BP-1 is a source operable unit with contaminated soils associated primarily with nine inactive cribs (known as the 216-B cribs). These cribs were used for disposal of low-level radioactive liquid waste from U Plant uranium recovery operations, and waste storage tank condensate from the adjacent 241-BY Tank Farm. The cribs used for disposal of U Plant waste were in operation from 1955--1965, and the cribs used for disposal of tank condensate were in operation from 1965--1975. In addition to the cribs, four unplanned releases of radioactive materials have occurred within the operable unit. Contaminated surface soils associated with the unplanned releases have been consolidated over the cribs and covered with clean soil to reduce contaminant migration and exposure. Discharge of wastes to the cribs has resulted in soil and groundwater contamination. The groundwater is being addressed as part of the 200 East Aggregate Area, groundwater operable unit. Contaminated soils at the site can be categorized by the types of contaminants, their distribution in the soil column, and the risk posed by the various potential exposure pathways. Below the clean soil cover, the near surface soils contain low-levels of contamination with cesium-137, radium-226, strontium-90, thorium-228, and uranium. The lifetime incremental cancer risk associated with these soils if they were exposed at the surface is 9{times}10{sup {minus}5}.

  3. Influence of sulfur physical properties in Claus unit operation

    Energy Technology Data Exchange (ETDEWEB)

    Larraz Mora, R.; Arvelo Alvarez, R. [Chemical Engineering Dept., Univ. of la Laguna, Tenerife (Spain)

    2002-09-01

    The Claus process is an efficient way of removing H{sub 2}S from acid gas streams and it has been widely practiced in industries such as natural gas processing, oil refining and metal smelting. Increasingly strict pollution control regulations require maximum sulfur recovery and high stream factor from the Claus units in order to minimize sulfur-containing effluents. As has been widely reported Claus unit's damages mainly occur during start up and shutdown. These operations involve scheduled warm-up and cool-down of the unit, usually burning refinery fuel-gas, which if not properly made can produce severe pipe and equipment plugging as well as catalyst deactivation. Sulfur products remaining in the unit during a shutdown period can produce dramatic unit corrosion episodes diminishing sulfur recovery unit stream factor. In the present paper some guidelines are given based on sulfur physical properties singularities which help to improve start-up/shut-down procedures. (orig.)

  4. Basewide Groundwater Operable Unit. Groundwater Operable Unit Remedial Investigation/Feasibility Study Report. Volume 2

    Science.gov (United States)

    1994-06-01

    V) V, ULZU CL. - -C -c- MnP .-j . - U. w bL. M4-4C, vi ..4Lu i4--l 9 c MEc L2 L 24- - -_.j< 4Z V)C 2 cc UU ’.w I- 4c0 0 -j Cc ~ U. cc u4- -lO 04 C4...contaminated well water exhibited hepatomegaly RDD10012C04.WP5 (OW RI•JF) B-58 3124M and abnormally high levels of hepatic enzyme levels. These

  5. Basewide Groundwater Operable Unit. Groundwater Operable Unit Remedial Investigation/Feasibility Study Report. Volume 3

    Science.gov (United States)

    1994-06-01

    of chemi- cal amendments will require regulatory approval. "* Water quality problems, such as reduced iron and manganese , methane, fer- mentation...irradiation dose, and water quality. Nickelsen et al. (1992) report that experimental data collected during the irradiation of potable water and wastewater...200- on old map new BW-20 170 392 170 222 170 392 212 Eau ne Building 93 on OMaley Avenue 154 378 154 192 154 346 12 E of the Bas, nea Wa Avene mid

  6. Basewide Groundwater Operable Unit. Groundwater Operable Unit Remedial Investigation/Feasibility Study Report. Volume 1

    Science.gov (United States)

    1994-06-01

    Force has replaced individual water wells with potable supply, thereby removing the threat to the public. In addi- tion, the concentrations are low and...94 LEGEND Ouatmar aluvi dposts agua Frmaion(cosoldatd aluval epoits W iead rdetilnsMhte omtin(neitccnlmeae ansoe9ndkeca F 70 Quvatei-lernayalvu e pk...have reconnected their private wells because of water restrictions during the drought, though none reported using their private wells for potable pur

  7. Analysis on Isolation Condenser Operation by Fukushima Daiichi Unit 1 Operators

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Man Cheol [Chungang University, Seoul (Korea, Republic of)

    2014-08-15

    Fukushima Daiichi nuclear accident resulted in the core damage in three reactors and the release of considerable amount of radioactive material to the environment, not to mention significant social impact and anti-nuclear atmosphere all around the world. This paper provides a review of the findings related to shift operators' operation of the isolation condenser in Unit 1 to examine shift operators' response to the situation. Based on the review of the findings, a situation assessment model was developed to analyze shift operators' understanding on whether core cooling was successfully performed in Unit 1 through the operation of isolation condenser. It was found that lack of information could be one of the main causes for the failure in core cooling by the IC in Unit 1. It is also recommended that the differences in the mathematical model for the situation assessment and that of the real operator need to be further investigated.

  8. Analysis on Operation Reliability of Generating Units in 2005

    Institute of Scientific and Technical Information of China (English)

    Zuo Xiaowen; Chu Xue

    2007-01-01

    @@ The weighted average equivalent availability factor of thermal power units in 2005 was 92.34%, an increase of 0.64 percentage points as compared to that in 2004. The average equivalent availability factor in 2005 was 92.22%, a decrease of 0.95 percentage points as compared to that in 2004. The nationwide operation reliability of generating units in 2005 was analyzed completely in this paper.

  9. LIQUID PHASE FISCHER-TROPSCH (III & IV) DEMONSTRATION IN THE LAPORTE ALTERNATIVE FUELS DEVELOPMENT UNIT. Final Topical Report. Volume I/II: Main Report. Task 1: Engineering Modifications (Fischer-Tropsch III & IV Demonstration) and Task 2: AFDU Shakedown, Operations, Deactivation (Shut-Down) and Disposal (Fischer-Tropsch III & IV Demonstration).

    Energy Technology Data Exchange (ETDEWEB)

    Bharat L. Bhatt

    1999-06-01

    Slurry phase Fischer-Tropsch technology was successfully demonstrated in DOE's Alternative Fuels Development Unit (AFDU) at LaPorte, Texas. Earlier work at LaPorte, with iron catalysts in 1992 and 1994, had established proof-of-concept status for the slurry phase process. The third campaign (Fischer-Tropsch III), in 1996, aimed at aggressively extending the operability of the slurry reactor using a proprietary cobalt catalyst. Due to an irreversible plugging of catalyst-wax separation filters as a result of unexpected catalyst fines generation, the operations had to be terminated after seven days on-stream. Following an extensive post-run investigation by the participants, the campaign was successfully completed in March-April 1998, with an improved proprietary cobalt catalyst. These runs were sponsored by the U. S. Department of Energy (DOE), Air Products & Chemicals, Inc., and Shell Synthetic Fuels, Inc. (SSFI). A productivity of approximately 140 grams (gm) of hydrocarbons (HC)/ hour (hr)-liter (lit) of expanded slurry volume was achieved at reasonable system stability during the second trial (Fischer-Tropsch IV). The productivity ranged from 110-140 at various conditions during the 18 days of operations. The catalyst/wax filters performed well throughout the demonstration, producing a clean wax product. For the most part, only one of the four filter housings was needed for catalyst/wax filtration. The filter flux appeared to exceed the design flux. A combination of use of a stronger catalyst and some innovative filtration techniques were responsible for this success. There was no sign of catalyst particle attrition and very little erosion of the slurry pump was observed, in contrast to the Fischer-Tropsch III operations. The reactor operated hydrodynamically stable with uniform temperature profile and gas hold-ups. Nuclear density and differential pressure measurements indicated somewhat higher than expected gas hold-up (45 - 50 vol%) during Fischer

  10. Eurodish-Continuous Operation, System Improvement and Reference Units

    Energy Technology Data Exchange (ETDEWEB)

    Keck, T.; Schiel, W.; Heller, P.; Reinalter, W.; Gineste, J. M.; Ferriere, A.; Flamant, G.

    2006-07-01

    The 10 kWel Dish/Stirling system EuroDish was enhanced. Newly developed and improved components like the ceramic cavity insulation and the control system are described as well as a novel assembly method for the concentrator and a number of improvements and new features of the control software. Country Reference Units were built in Spain, France and Germany and are continuously operated. Operation experiences and performance data are presented. (Author)

  11. 77 FR 62247 - Dynamic Positioning Operations Guidance for Vessels Other Than Mobile Offshore Drilling Units...

    Science.gov (United States)

    2012-10-12

    ...] Dynamic Positioning Operations Guidance for Vessels Other Than Mobile Offshore Drilling Units Operating on... voluntary guidance titled ``Mobile Offshore Drilling Unit Dynamic Positioning Guidance''. The notice recommended owners and operators of Mobile Offshore Drilling Units (MODUs) follow Marine Technology...

  12. Refining United States Policy on Offensive Cyber Operations

    Science.gov (United States)

    2014-11-01

    address state- sponsored cyber threats with a very different set of tools ranging from diplomacy to kinetic strikes. Categorizing attacks by actor will...AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY REFINING UNITED STATES POLICY ON OFFENSIVE CYBER OPERATIONS by Max...to offensive cyber warfare, specifically cyber exploitation and cyber attack. Current domestic and international policies lack mechanisms to

  13. Semiconductor Chemical Reactor Engineering and Photovoltaic Unit Operations.

    Science.gov (United States)

    Russell, T. W. F.

    1985-01-01

    Discusses the nature of semiconductor chemical reactor engineering, illustrating the application of this engineering with research in physical vapor deposition of cadmium sulfide at both the laboratory and unit operations scale and chemical vapor deposition of amorphous silicon at the laboratory scale. (JN)

  14. Unit Operation Experiment Linking Classroom with Industrial Processing

    Science.gov (United States)

    Benson, Tracy J.; Richmond, Peyton C.; LeBlanc, Weldon

    2013-01-01

    An industrial-type distillation column, including appropriate pumps, heat exchangers, and automation, was used as a unit operations experiment to provide a link between classroom teaching and real-world applications. Students were presented with an open-ended experiment where they defined the testing parameters to solve a generalized problem. The…

  15. Biomass publications of the forest operations research unit: A synthesis

    Science.gov (United States)

    Dana Mitchell; Renee Ayala; [Compilers

    2005-01-01

    The Forest Operations Unit of the Southern Research Station has been studying biomass-related topics since 1977. This CD aids the reader by organizing these publications in one easy-to-use CD. This CD is comprised of an executive summary, two bibliographies, individual publications (in PDF format), and a keyword listing. The types of publications included on this CD...

  16. Adaptation of Professional Skills in the Unit Operations Laboratory

    Science.gov (United States)

    Rende, Deniz; Rende, Sevinc; Baysal, Nihat

    2012-01-01

    We introduce the design of three consecutive unit operations laboratory (UOL) courses that retain the academic rigor of the course while incorporating skills essential for professional careers, such as ability to propose ideas, develop practical solutions, participate in teamwork, meet deadlines, establish communication between technical support…

  17. Impact of implementation of a pediatric surgery fellowship on general surgery resident operative volume.

    Science.gov (United States)

    Snyder, Rebecca A; Phillips, Sharon E; Terhune, Kyla P

    2012-01-01

    The purpose of this study was to determine the impact of the initiation of a pediatric surgery fellowship on general surgery resident operative volume at 1 major academic institution. Retrospective review of operative records obtained from the Accreditation Council for Graduate Medical Education (ACGME) general surgery resident and pediatric surgery fellow case logs. Data collected included number and type of pediatric index cases per year, number of total pediatric surgery cases per year, and number of total cases logged as primary surgeon to date. Vanderbilt University School of Medicine Department of Surgery, which has an accredited general surgery program, finishes 7 chief residents per year during the study period, and instituted a new pediatric surgery fellowship in 2007. Case logs submitted by third and fourth year general surgery residents and first and second year pediatric surgery fellows were studied. The number of pediatric attending surgeons, relative value units (RVUs), and hospital admissions increased from 2003 to 2011. The median number of pediatric index cases performed by a resident decreased after the onset of fellowship from 34 cases to 23.5 cases per year (p pediatric surgery rotation also decreased from 74 to 53 cases per year after onset of the fellowship (p surgery resident index and overall case volume in pediatric surgery. Although operative volume is only 1 measure of surgical educational value, these findings suggest that the addition of surgical fellowships affects the educational experience of general surgery residents. We recommend that residency programs establish goals and calculate any potential impact on general surgery resident case volume before initiating a new surgical fellowship. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  18. Measures of coherence-generating power for quantum unital operations

    Science.gov (United States)

    Zanardi, Paolo; Styliaris, Georgios; Campos Venuti, Lorenzo

    2017-05-01

    Given an orthonormal basis B in a d -dimensional Hilbert space and a unital quantum operation E acting on it, one can define a nonlinear mapping that associates with E a d ×d real-valued matrix that we call the coherence matrix of E with respect to B . This is the Gram matrix of the coherent part of the basis projections of B under E . We show that one can use this coherence matrix to define vast families of measures of the coherence-generating power (CGP) of the operation. These measures have a natural geometrical interpretation as separation of E from the set of incoherent unital operations. The probabilistic approach to CGP discussed in P. Zanardi et al. [Phys. Rev. A 95, 052306 (2017)., 10.1103/PhysRevA.95.052306] can be reformulated and generalized, introducing, alongside the coherence matrix, another d ×d real-valued matrix, the simplex correlation matrix. This matrix describes the relevant statistical correlations in the input ensemble of incoherent states. Contracting these two matrices, one finds CGP measures associated with the process of preparing the given incoherent ensemble and processing it with the chosen unital operation. Finally, in the unitary case, we discuss how these concepts can be made compatible with an underlying tensor product structure by defining families of CGP measures that are additive.

  19. Advanced Transport Operating System (ATOPS) control display unit software description

    Science.gov (United States)

    Slominski, Christopher J.; Parks, Mark A.; Debure, Kelly R.; Heaphy, William J.

    1992-01-01

    The software created for the Control Display Units (CDUs), used for the Advanced Transport Operating Systems (ATOPS) project, on the Transport Systems Research Vehicle (TSRV) is described. Module descriptions are presented in a standardized format which contains module purpose, calling sequence, a detailed description, and global references. The global reference section includes subroutines, functions, and common variables referenced by a particular module. The CDUs, one for the pilot and one for the copilot, are used for flight management purposes. Operations performed with the CDU affects the aircraft's guidance, navigation, and display software.

  20. Stability Analysis for Operation of DG Units in Smart Grids

    DEFF Research Database (Denmark)

    Pouresmaeil, Edris; Shaker, Hamid Reza; Mehrasa, Majid

    2015-01-01

    This paper presents a multifunction control strategy for the stable operation of Distributed Generation (DG) units during grid integration. The proposed control model is based on Direct Lyapunov Control (DLC) theory and provides a stable region for the appropriate operation of DG units during grid...... integration. Using DLC technique in DG technology can provide the continuous injection of maximum active power in fundamental frequency from the DG source to the grid, compensating all reactive power and harmonic current components of grid-connected loads through the integration of DG link into the grid....... Application of this concept can guarantee to reduce the stress on the grid during the energy demand peak. Simulation results are presented to demonstrate the proficiency and performance of the proposed DLC technique in DG technology....

  1. Development and operation of 1 MW wind power unit

    Energy Technology Data Exchange (ETDEWEB)

    Seleznev, I.; Lavrov, V. [Machine-building Design Bureau, (Russian Federation)

    1996-12-31

    Development of wind power units (WPUs), which operate on renewable wind power, as well as combined power sources including WPUs, have an important national economic significance in the Russian Federation, particularly in the areas of construction and operation of nuclear power plants, hydro-electric stations and other traditional power plants. Development of WPUs of high power level is a complicated task, and the solution requires investigations in the areas of experimental design, technology, and the organization of industrial production. Initially, the problem of the development of large diameter propellers, power electric equipment, reducers and drive mechanisms, automatic control devices, and control and diagnostic system need to be solved. This report covers the basic results and directions of the work of the Machine-building Design Bureau `Raduga` in the field of wind power engineering as well as the basic performance of the units. (author). 7 figs.

  2. Thermodynamics of Condensed Phases: Formula Unit Volume, "V[subscript m]", and the Determination of the Number of Formula Units, "Z", in a Crystallographic Unit Cell

    Science.gov (United States)

    Glasser, Leslie

    2011-01-01

    Formula unit (or molecular) volume, "V[subscript m]", is related to many thermodynamic and physical properties of materials, so that knowledge of "V[subscript m]" is useful in prediction of such properties for known and even hypothetical materials. The symbol "Z" represents the number of formula units in a crystallographic unit cell; "Z" thus…

  3. [Operational units for health risk management (patient safety)].

    Science.gov (United States)

    Pardo Hernández, A; Claveria Fontán, A; García Urbaneja, M; López Barba, J

    2008-12-01

    In 1995 INSALUD began to develop performance measures in the field of risk management, and following transfer of powers to the regions, these led to the development of operational units in individual healthcare centres. These units, which consist of a group of health professionals, including managers, aim to identify, evaluate, analyse and deal with health risks, to enhance patient safety. Their organisational structure can vary in accordance with the needs, resources and philosophy of each individual organisation. This paper presents the experience of the risk management units developed in four Spanish regions: Madrid, the Basque Country, Galicia and INGESA (Ceuta and Melilla). It also includes reflections on assessment of their impact and on their future role in improving safety in healthcare services.

  4. Analysis of viral clearance unit operations for monoclonal antibodies.

    Science.gov (United States)

    Miesegaes, George; Lute, Scott; Brorson, Kurt

    2010-06-01

    Demonstration of viral clearance is a critical step in assuring the safety of biotechnology products. We generated a viral clearance database that contains product information, unit operation process parameters, and viral clearance data from monoclonal antibody and antibody-related regulatory submissions to FDA. Here we present a broad overview of the database and resulting analyses. We report that the diversity of model viruses tested expands as products transition to late-phase. We also present averages and ranges of viral clearance results by Protein A and ion exchange chromatography steps, low pH chemical inactivation, and virus filtration, focusing on retro- and parvoviruses. For most unit operations, an average log reduction value (LRV, a measure of clearance power) for retrovirus of >4 log(10) were measured. Cases where clearance data fell outside of the anticipated range (i.e., outliers) were rationally explained. Lastly, a historical analysis did not find evidence of any improvement trend in viral clearance over time. The data collectively suggest that many unit operations in general can reliably clear viruses.

  5. Electric power annual 1994. Volume 2, Operational and financial data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-28

    This year, the annual is published in two volumes. Volume I focused on US electric utilities and contained final 1994 data on net generation, fossil fuel consumption, stocks, receipts, and cost. This Volume II presents annual 1994 summary statistics for the electric power industry, including information on both electric utilities and nonutility power producers. Included are preliminary data for electric utility retail sales of electricity, associated revenue, and average revenue per kilowatthour of electricity sold (based on form EIA-861) and for electric utility financial statistics, environmental statistics, power transactions, and demand- side management. Final 1994 data for US nonutility power producers on installed capacity and gross generation, as well as supply and disposition information, are also provided in Volume II. Technical notes and a glossary are included.

  6. Units of Instruction. Health Occupations Education. Volume I. [Teacher's Guide].

    Science.gov (United States)

    East Texas State Univ., Commerce. Occupational Curriculum Lab.

    Ten units on health occupations are presented in this teacher's guide. The units are the following: recording vital signs; job application and interview; grooming and personal hygiene; health careers; medical careers; medical ethics; medical terminology and abbreviations; medical asepsis; basic patient care (e.g., measuring and recording fluid…

  7. An ancient relation between units of length and volume based on a sphere.

    Directory of Open Access Journals (Sweden)

    Elena Zapassky

    Full Text Available The modern metric system defines units of volume based on the cube. We propose that the ancient Egyptian system of measuring capacity employed a similar concept, but used the sphere instead. When considered in ancient Egyptian units, the volume of a sphere, whose circumference is one royal cubit, equals half a hekat. Using the measurements of large sets of ancient containers as a database, the article demonstrates that this formula was characteristic of Egyptian and Egyptian-related pottery vessels but not of the ceramics of Mesopotamia, which had a different system of measuring length and volume units.

  8. Turnaround operations analysis for OTV. Volume 2: Detailed technical report

    Science.gov (United States)

    1988-01-01

    The objectives and accomplishments were to adapt and apply the newly created database of Shuttle/Centaur ground operations. Previously defined turnaround operations analyses were to be updated for ground-based OTVs (GBOTVs) and space-based OTVs (SBOTVs), design requirements identified for both OTV and Space Station accommodations hardware, turnaround operations costs estimated, and a technology development plan generated to develop the required capabilities. Technical and programmatic data were provided for NASA pertinent to OTV round and space operations requirements, turnaround operations, task descriptions, timelines and manpower requirements, OTV modular design and booster and Space Station interface requirements. SBOTV accommodations development schedule, cost and turnaround operations requirements, and a technology development plan for ground and space operations and space-based accommodations facilities and support equipment. Significant conclusion are discussed.

  9. WTP Waste Feed Qualification: Glass Fabrication Unit Operation Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Stone, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Hanford Missions Programs; Newell, J. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Process Technology Programs; Johnson, F. C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Engineering Process Development; Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Engineering Process Development

    2016-07-14

    The waste feed qualification program is being developed to protect the Hanford Tank Waste Treatment and Immobilization Plant (WTP) design, safety basis, and technical basis by assuring waste acceptance requirements are met for each staged waste feed campaign prior to transfer from the Tank Operations Contractor to the feed receipt vessels inside the Pretreatment Facility. The Waste Feed Qualification Program Plan describes the three components of waste feed qualification: 1. Demonstrate compliance with the waste acceptance criteria 2. Determine waste processability 3. Test unit operations at laboratory scale. The glass fabrication unit operation is the final step in the process demonstration portion of the waste feed qualification process. This unit operation generally consists of combining each of the waste feed streams (high-level waste (HLW) and low-activity waste (LAW)) with Glass Forming Chemicals (GFCs), fabricating glass coupons, performing chemical composition analysis before and after glass fabrication, measuring hydrogen generation rate either before or after glass former addition, measuring rheological properties before and after glass former addition, and visual observation of the resulting glass coupons. Critical aspects of this unit operation are mixing and sampling of the waste and melter feeds to ensure representative samples are obtained as well as ensuring the fabrication process for the glass coupon is adequate. Testing was performed using a range of simulants (LAW and HLW simulants), and these simulants were mixed with high and low bounding amounts of GFCs to evaluate the mixing, sampling, and glass preparation steps in shielded cells using laboratory techniques. The tests were performed with off-the-shelf equipment at the Savannah River National Laboratory (SRNL) that is similar to equipment used in the SRNL work during qualification of waste feed for the Defense Waste Processing Facility (DWPF) and other waste treatment facilities at the

  10. Method and apparatus for operating an improved thermocline storage unit

    Science.gov (United States)

    Copeland, Robert J.

    1985-01-01

    A method and apparatus for operating a thermocline storage unit in which an insulated barrier member is provided substantially at the interface region between the hot and cold liquids in the storage tank. The barrier member physically and thermally separates the hot and cold liquids substantially preventing any diffusing or mixing between them and substantially preventing any heat transfer therebetween. The barrier member follows the rise and fall of the interface region between the liquids as the tank is charged and discharged. Two methods of maintaining it in the interface region are disclosed. With the structure and operation of the present invention and in particular the significant reduction in diffusing or mixing between the hot and cold liquids as well as the significant reduction in the thermal heat transfer between them, the performance of the storage tank is improved. More specifically, the stability of the interface region or thermocline is enhanced and the thickness of the thermocline is reduced producing a corresponding increase in the steepness of the temperature gradient across the thermocline and a more efficiently operating thermocline storage unit.

  11. The United States national volcanic ash operations plan for aviation

    Science.gov (United States)

    Albersheim, Steven; Guffanti, Marianne

    2009-01-01

    Volcanic-ash clouds are a known hazard to aviation, requiring that aircraft be warned away from ash-contaminated airspace. The exposure of aviation to potential hazards from volcanoes in the United States is significant. In support of existing interagency operations to detect and track volcanic-ash clouds, the United States has prepared a National Volcanic Ash Operations Plan for Aviation to strengthen the warning process in its airspace. The US National Plan documents the responsibilities, communication protocols, and prescribed hazard messages of the Federal Aviation Administration, National Oceanic and Atmospheric Administration, US Geological Survey, and Air Force Weather Agency. The plan introduces a new message format, a Volcano Observatory Notice for Aviation, to provide clear, concise information about volcanic activity, including precursory unrest, to air-traffic controllers (for use in Notices to Airmen) and other aviation users. The plan is online at http://www.ofcm.gov/p35-nvaopa/pdf/FCM-P35-2007-NVAOPA.pdf. While the plan provides general operational practices, it remains the responsibility of the federal agencies involved to implement the described procedures through orders, directives, etc. Since the plan mirrors global guidelines of the International Civil Aviation Organization, it also provides an example that could be adapted by other countries.

  12. United States Coast Pilot (volume 1 through 9)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The United States Coast Pilot is a series of 9 nautical books that cover a wide variety of information important to navigators of U.S. coastal and intercoastal...

  13. Severe and fatal obstetric injury claims in relation to labor unit volume

    DEFF Research Database (Denmark)

    Milland, Maria; Mikkelsen, Kim L; Christoffersen, Jens K

    2015-01-01

    with decreasing annual delivery volume. Face value incidence rate ratios of approved severe injuries increased with decreasing labor unit volume, but the association did not reach statistical significance. CONCLUSION: High volume labor units appear associated with fewer approved and fewer fatal injury claims...... quintiles as annual volume per labor unit: (10-1377), (1378-2016), (2017-2801), (2802-3861), (3862-6659). MAIN OUTCOME MEASURES: Five primary measures of outcome were used. Incidence rate ratios of (A) Submitted claims, (B) Approved claims, (C) Approved severe injury claims (120% degree of disability), (D......) Approved fatal injury claims, and (C+D) Combined. RESULTS: 1 151 734 deliveries in 51 labor units and 1872 submitted claims were included. The incidence rate ratios of approved claims overall, of approved fatal injury claims, and of approved severe and fatal injuries combined increased significantly...

  14. Topics in Cognitive Development: Language and Operational Thought. Volume 2.

    Science.gov (United States)

    Presseisen, Barbara Z.; And Others

    This is the second volume in a series that records the official Symposium Proceedings of the Jean Piaget Society and examines the theoretical, empirical, and applied aspects of Jean Piaget's seminal epistemology. The 12 papers are divided into four areas: language development, formal reasoning, social cognition, and applied research. The topics of…

  15. Topics in Cognitive Development: Language and Operational Thought. Volume 2.

    Science.gov (United States)

    Presseisen, Barbara Z.; And Others

    This is the second volume in a series that records the official Symposium Proceedings of the Jean Piaget Society and examines the theoretical, empirical, and applied aspects of Jean Piaget's seminal epistemology. The 12 papers are divided into four areas: language development, formal reasoning, social cognition, and applied research. The topics of…

  16. Article separation apparatus and method for unit operations

    Science.gov (United States)

    Pardini, Allan F.; Gervais, Kevin L.; Mathews, Royce A.; Hockey, Ronald L.

    2010-06-22

    An apparatus and method are disclosed for separating articles from a group of articles. The apparatus includes a container for containing one or more articles coupled to a suitable fluidizer for suspending articles within the container and transporting articles to an induction tube. A portal in the induction tube introduces articles singly into the induction tube. A vacuum pulls articles through the induction tube separating the articles from the group of articles in the container. The apparatus and method can be combined with one or more unit operations or modules, e.g., for inspecting articles, assessing quality of articles, or ascertaining material properties and/or parameters of articles, including layers thereof.

  17. Feasibility Study for Operable Unit 7-13/14

    Energy Technology Data Exchange (ETDEWEB)

    K. Jean Holdren

    2007-05-29

    The Subsurface Disposal Area is a radioactive waste landfill located within the Radioactive Waste Management Complex at the Idaho National Laboratory Site in southeastern Idaho. This Feasibility Study for Operable Unit 7-13/14 analyzes options for mitigating risks to human health and the environment associated with the landfill. Analysis is conducted in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act, using nine evaluation criteria to develop detailed and comparative analysis of five assembled alternatives. Assembled alternatives are composed of discrete modules. Ultimately, decision-makers will select, recombine, and sum various modules into an optimized preferred alternative and final remedial decision.

  18. CTS (Hermes): United States experiments and operations summary

    Science.gov (United States)

    Donoughe, P. L.; Hunczak, H. R.

    1977-01-01

    The Communications Technology Satellite, launched in January 1976 and embodying the highest power transmitter in a communications satellite, was considered. As a joint program between the U.S. and Canada, close coordination of the two countries was necessitated since the management and control of experiments were done in real time. Criteria used by NASA for acceptance of the United States experiments are noted and acceptance procedures are discussed. The category for each accepted experiment is given. The modus operandi employed for the U.S. experiments in the areas of management, coordination, liaison, and real time operation are described. Some of the highlights associated with satellite utilization are given.

  19. The Small Aircraft Transportation System (SATS), Higher Volume Operations (HVO) Concept and Research

    Science.gov (United States)

    Baxley, B.; Williams, D.; Consiglio, M.; Adams, C.; Abbott, T.

    2005-01-01

    The ability to conduct concurrent, multiple aircraft operations in poor weather at virtually any airport offers an important opportunity for a significant increase in the rate of flight operations, a major improvement in passenger convenience, and the potential to foster growth of operations at small airports. The Small Aircraft Transportation System, (SATS) Higher Volume Operations (HVO) concept is designed to increase capacity at the 3400 non-radar, non-towered airports in the United States where operations are currently restricted to one-in/one-out procedural separation during low visibility or ceilings. The concept s key feature is that pilots maintain their own separation from other aircraft using air-to-air datalink and on-board software within the Self-Controlled Area (SCA), an area of flight operations established during poor visibility and low ceilings around an airport without Air Traffic Control (ATC) services. While pilots self-separate within the SCA, an Airport Management Module (AMM) located at the airport assigns arriving pilots their sequence based on aircraft performance, position, winds, missed approach requirements, and ATC intent. The HVO design uses distributed decision-making, safe procedures, attempts to minimize pilot and controller workload, and integrates with today's ATC environment. The HVO procedures have pilots make their own flight path decisions when flying in Instrument Metrological Conditions (IMC) while meeting these requirements. This paper summarizes the HVO concept and procedures, presents a summary of the research conducted and results, and outlines areas where future HVO research is required. More information about SATS HVO can be found at http://ntrs.nasa.gov.

  20. Research on Controlled Volume Operation Method of Large-scale Water Transfer Canal

    Institute of Scientific and Technical Information of China (English)

    DING Zhiliang; WANG Changde; XU Duo; XIAO Hua

    2011-01-01

    The controlled volume method of operation is especially suitable for large-scale water delivery canal system with complex operation requirements. An operating simulation model based on the storage volume control method for multi-reach canal system in series was established. In allusion to the deficiency of existing controlled volume algorithm, the improved controlled volume algorithm of the whole canal pools was proposed, and the simulation results indicated that the storage volume and water level of each canal pool could be accurately controlled after the improved algorithm had been adopted. However, for some typical discharge demand operating conditions, if the previously mentioned algorithm was adopted, then it certainly would cause some unnecessary gate adjustments, and consequently the disturbed canal pools would be increased. Therefore, the idea of controlled volume operation method of continuous canal pools was proposed, and corresponding algorithm was designed. Through simulating practical project, the results indicated that the new controlled volume algorithm proposed for typical operating conditions could comparatively and obviously reduce the number of regulated check gates and disturb canal pools for some typical discharge demand operating conditions, thus the control efficiency of canal system could be improved.

  1. Summary of Notifiable Diseases, United States. Volume 45, Number 53.

    Science.gov (United States)

    1997-10-31

    Encephalitis, eastern equine Encephalitis, St. Louis Encephalitis, western equine Escherichia co//0157:H7 Gonorrhea Haemophilus influenzae , invasive...viral zoonosis caused by Sin Nombre virus and other New World hantaviruses which, in the United States, include Bayou virus, Black Creek Canal virus

  2. What the Planner Needs to Know. Volume I. About the Debris Environment. Volume 2. About Debris Clearing Operations

    Science.gov (United States)

    1975-06-01

    a priority basis. Re- visions of inventories and the supply and maintenance of actual clearing operations will then proceed. c VOLUME I WHAT THE...Making Debris Predicition Survey I Potential Emergency | -j Operations - | ’ Clearing Routes, etc.j ± Completed DPS File...three types of primary equipment would be preferred. Mechanics (Grade 2) for maintenance and repair are slightly less critical than experienced

  3. Operations analysis (study 2.1). Volume 1: Executive summary

    Science.gov (United States)

    Wolfe, R. R.

    1975-01-01

    Subjects related to future STS operations concepts were investigated. The majority of effort was directed at assessing the benefits of automated space servicing concepts as related to improvements in payload procurement and shuttle utilization. Another subject was directed at understanding shuttle upper stage software development and recurring costs relative to total program projections. Space serving of automated payloads is addressed by examining the broad spectrum of payload applications with the belief that shared logistic operations will be a major contributor to reduction of future program costs. However, there are certain requirements for support of payload operations, such as availability of the payload, that may place demands upon the shuttle fleet. Because future projections of the NASA Mission Model are only representative of the payload traffic, it is important to recognize that it is the general character of operations that is significant rather than service to any single payload program.

  4. Automated processing of whole blood units: operational value and in vitro quality of final blood components

    Science.gov (United States)

    Jurado, Marisa; Algora, Manuel; Garcia-Sanchez, Félix; Vico, Santiago; Rodriguez, Eva; Perez, Sonia; Barbolla, Luz

    2012-01-01

    Background The Community Transfusion Centre in Madrid currently processes whole blood using a conventional procedure (Compomat, Fresenius) followed by automated processing of buffy coats with the OrbiSac system (CaridianBCT). The Atreus 3C system (CaridianBCT) automates the production of red blood cells, plasma and an interim platelet unit from a whole blood unit. Interim platelet unit are pooled to produce a transfusable platelet unit. In this study the Atreus 3C system was evaluated and compared to the routine method with regards to product quality and operational value. Materials and methods Over a 5-week period 810 whole blood units were processed using the Atreus 3C system. The attributes of the automated process were compared to those of the routine method by assessing productivity, space, equipment and staffing requirements. The data obtained were evaluated in order to estimate the impact of implementing the Atreus 3C system in the routine setting of the blood centre. Yield and in vitro quality of the final blood components processed with the two systems were evaluated and compared. Results The Atreus 3C system enabled higher throughput while requiring less space and employee time by decreasing the amount of equipment and processing time per unit of whole blood processed. Whole blood units processed on the Atreus 3C system gave a higher platelet yield, a similar amount of red blood cells and a smaller volume of plasma. Discussion These results support the conclusion that the Atreus 3C system produces blood components meeting quality requirements while providing a high operational efficiency. Implementation of the Atreus 3C system could result in a large organisational improvement. PMID:22044958

  5. Toward a warfighter's associate: eliminating the operator control unit

    Science.gov (United States)

    Everett, Hobart R.; Pacis, Estrellina B.; Kogut, Greg; Farrington, Nathan M.; Khurana, S.

    2004-12-01

    In addition to the challenges of equipping a mobile robot with the appropriate sensors, actuators, and processing electronics necessary to perform some useful function, there coexists the equally important challenge of effectively controlling the system"s desired actions. This need is particularly critical if the intent is to operate in conjunction with human forces in a military application, as any low-level distractions can seriously reduce a warfighter"s chances of survival in hostile environments. Historically there can be seen a definitive trend towards making the robot smarter in order to reduce the control burden on the operator, and while much progress has been made in laboratory prototypes, all equipment deployed in theatre to date has been strictly teleoperated. There exists a definite tradeoff between the value added by the robot, in terms of how it contributes to the performance of the mission, and the loss of effectiveness associated with the operator control unit. From a command-and-control perspective, the ultimate goal would be to eliminate the need for a separate robot controller altogether, since it represents an unwanted burden and potential liability from the operator"s perspective. This paper introduces the long-term concept of a supervised autonomous Warfighter"s Associate, which employs a natural-language interface for communication with (and oversight by) its human counterpart. More realistic near-term solutions to achieve intermediate success are then presented, along with actual results to date. The primary application discussed is military, but the concept also applies to law enforcement, space exploration, and search-and-rescue scenarios.

  6. Operating manual for the High Flux Isotope Reactor. Volume I. Description of the facility

    Energy Technology Data Exchange (ETDEWEB)

    1982-09-01

    This volume contains a comprehensive description of the High Flux Isotope Reactor Facility. Its primary purpose is to supplement the detailed operating procedures, providing the reactor operators with background information on the various HFIR systems. The detailed operating procdures are presented in another report.

  7. Health Occupations Curriculum. Skills and Theory for Health Assistant. Volume I, Units 1-4.

    Science.gov (United States)

    Arizona State Dept. of Education, Phoenix.

    This volume consists of the first four units of a basic core curriculum that is intended for all health workers. The units deal with the following topics: (1) the health care facility, the long-term care facility, the health team, and the nursing team; (2) verbal and nonverbal communication, written communication, human behavior, ethical behavior,…

  8. Health Occupations Curriculum. Skills and Theory for Health Assistant. Volume 2, Units 5-7.

    Science.gov (United States)

    Arizona State Dept. of Education, Phoenix.

    This volume consists of three units of a basic core curriculum that is intended for all health workers. Covered in the units are the following topics: (1) the body's need for food, the effect of food on the body, the five food groups, the six nutrients, and therapeutic diets; (2) general principles of asepsis, specific methods of maintaining…

  9. Volume of activity and occupancy rate in intensive care units. Association with mortality

    NARCIS (Netherlands)

    Iapichino, G; Gattinoni, L; Radrizzani, D; Simini, B; Bertolini, G; Ferla, L; Mistraletti, G; Porta, F; Miranda, DR

    Objective. Mortality after many procedures is lower in centers where more procedures are done. It is controversial whether this is true for intensive care units, too. We examined the relationship between the volume of activity of intensive care units (ICUs) and mortality by a measure of

  10. Journal of Special Operations Medicine, Volume 3, Edition 3

    Science.gov (United States)

    2003-01-01

    These medications, known by their trade names Tagamet® (cimetidine), Pepcid® (famotidine), Axid® (nizatidine), and Zantac® ( ranitidine ) selectively...Claritin Reditabs®) as the first non-sedat- ing antihistamine available in the United States with- out a prescription. Its formulation and dosing are the...the Special Forces Medic. The Chief Medical Aidman’s Course, formulated by 1st Lt Elliott, was specifically designed for Special Forces Medics. Once

  11. Better Assessment of Operational Suitability. Volume 2. Case Studies

    Science.gov (United States)

    1992-01-01

    improved bolts Salt-water fording No changes required, waterproof system Cold starting Additional grounding straps, rerouting of preheate exhaust Front...window, but the impact is primarily cosmetic . Video degradation requires prolonged operation in the sand environment and is gradual. In SWA, 24 windows

  12. Transuranic (Tru) waste volume reduction operations at a plutonium facility

    Energy Technology Data Exchange (ETDEWEB)

    Cournoyer, Michael E [Los Alamos National Laboratory; Nixon, Archie E [Los Alamos National Laboratory; Dodge, Robert L [Los Alamos National Laboratory; Fife, Keith W [Los Alamos National Laboratory; Sandoval, Arnold M [Los Alamos National Laboratory; Garcia, Vincent E [Los Alamos National Laboratory

    2010-01-01

    Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA 55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). Size-reduction operations on glovebox equipment are a common activity when a process has been discontinued and the room is being modified to support a new customer. The Actin ide Processing Group at TA-55 uses one-meter-long glass columns to process plutonium. Disposal of used columns is a challenge, since they must be size-reduced to get them out of the glovebox. The task is a high-risk operation because the glass shards that are generated can puncture the bag-out bags, leather protectors, glovebox gloves, and the worker's skin when completing the task. One of the Lessons Learned from these operations is that Laboratory management should critically evaluate each hazard and provide more effective measures to prevent personnel injury. A bag made of puncture-resistant material was one of these enhanced controls. We have investigated the effectiveness of these bags and have found that they safely and effectively permit glass objects to be reduced to small pieces with a plastic or rubber mallet; the waste can then be easily poured into a container for removal from the glove box as non-compactable transuranic (TRU) waste. This size-reduction operation reduces solid TRU waste generation by almost 2% times. Replacing one-time-use bag-out bags with multiple-use glass crushing bags also contributes to reducing generated waste. In addition, significant costs from contamination, cleanup, and preparation of incident documentation are avoided. This effort contributes to the Los Alamos

  13. Analytical Chemistry Laboratory (ACL) procedure compendium. Volume 7, Safety operation procedure for hot cell

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    This volume contains the interim change notice for the safety operation procedure for hot cell. It covers the master-slave manipulators, dry waste removal, cell transfers, hoists, cask handling, liquid waste system, and physical characterization of fluids.

  14. Hospital volume and post-operative mortality after resection for gastric cancer

    NARCIS (Netherlands)

    Damhuis, RAM; Meurs, CJC; Dijkhuis, CM; Stassen, LPS; Wiggers, T

    2002-01-01

    Aims: In low-volume hospitals, expertise in gastric surgery is difficult to maintain because of the decreasing incidence of gastric cancer and the fall of surgery for ulcer disease. We evaluated the prognostic impact of hospital volume on post-operative mortality (POM) in a consecutive series of 197

  15. Hospital volume and post-operative mortality after resection for gastric cancer

    NARCIS (Netherlands)

    Damhuis, RAM; Meurs, CJC; Dijkhuis, CM; Stassen, LPS; Wiggers, T

    Aims: In low-volume hospitals, expertise in gastric surgery is difficult to maintain because of the decreasing incidence of gastric cancer and the fall of surgery for ulcer disease. We evaluated the prognostic impact of hospital volume on post-operative mortality (POM) in a consecutive series of

  16. General Urban Warfare Amphibious Logistics Applications. Volume 2. Operations Plan.

    Science.gov (United States)

    1983-06-23

    Appendix 7 (Engineer Support Plan). Estimated Priority Bridae Task Size Unit Assigned 1 1, 3, 5 Co.(-) 7th Engr Spt Bn 2 6, 7, 8, 10 Pit.(+) 7th Engr Spt... BrIda OtnarAl U. S149Ay Cr ogS~y~po~m B~n. I ~litrhotlnl OC-400n0la 14 i l IA cvV (DAREEP IV03R2 I F IUIVTGNEA W UNCLASIFIE IgdirGo ,1 VA .CM Marf tf

  17. Ground Operations Aerospace Language (GOAL). Volume 2: Compiler

    Science.gov (United States)

    1973-01-01

    The principal elements and functions of the Ground Operations Aerospace Language (GOAL) compiler are presented. The technique used to transcribe the syntax diagrams into machine processable format for use by the parsing routines is described. An explanation of the parsing technique used to process GOAL source statements is included. The compiler diagnostics and the output reports generated during a GOAL compilation are explained. A description of the GOAL program package is provided.

  18. The Generalized Trajectory Simulation System. Volume 4. Numerical Operators

    Science.gov (United States)

    1976-04-15

    Aerospace Corporation by D.A. Schermerhorn and A. R. Sims, Engineering Science Operations. The Air Force Project Engineer was Lt. Joe Hildreth, AFRPL...foreign nations. Gerhard E. Aichinger T echnica! &.4-d;a. " Contracts Management Office FOR THE COMMANDLR T iaK J.’ B an - Chief, Contrat Management ...L I VA LflUI CODES JUN 14 1978 , I WMAL iv PR(CEDIM PA34aBL•l•Ipr F- CONTENTS Page 1. INTRODUCTION ............. ......................... . - 2

  19. Ensuring Operational Readiness: Private Military Contractor Support for the United States Air Force

    Science.gov (United States)

    2017-03-15

    Ensuring Operational Readiness: Private Military Contractor Support for the United States Air Force A Monograph by Maj Stephen P. Joca United...States Air Force School of Advanced Military Studies United States Army Command and General Staff College Fort Leavenworth, Kansas 2017 Approved...Operational Readiness: Private Military Contractor Support for the United States Air Force Approved by: __________________________________, Monograph

  20. Particle Emissions from District Heating Units Operating on Solid Biofuels

    Energy Technology Data Exchange (ETDEWEB)

    Wierzbicka, Aneta [Lund Inst. of Technology (Sweden). Div. of Ergonomics and Aerosol Technology

    2005-06-01

    With the increasing interest in the use of biofuels for heat and energy generation there is a growing concern about emissions from their combustion. It has been shown that biofuel furnaces emit relatively high quantities of particulate matter in comparison to natural gas and light fuel oil furnaces. Majority of the emitted particulates are smaller than 10 {mu}m with high contribution of fine (<2.5 {mu}m) and submicron (<1 {mu}m) particles. These fine particles tend to be the most troublesome: in ambient air they have been associated with adverse health effects. Submicron particles are difficult to capture in the available particle removal technologies. The aim of this study was to characterise particle emissions from district heating units operating on three commonly used biofuels, namely sawdust. pellets and forest residues. Boilers were of moving grate type. with the maximum thermal output between 1 and 1.5 MW. The measurements were done after multi cyclones, the only particle removal devices installed, therefore the direct emissions to ambient air were characterised. Influence of type of the fuel and operation load on particle emissions was investigated. Furthermore, collection efficiencies of electrostatic precipitator (ESP) and flue gas condenser, used particle separation devices in 6 MW unit, were investigated. It has been shown that in all cases large amounts of fuel particles containing heavy metals are being emitted to the atmosphere, even though the studied district heating units meet the current mass concentration emission limit requirements. Total number concentration of emitted particles with aerodynamic diameter smaller than 5 {mu}m ranged from 3 to 8x10{sup 7} particles/cm{sub n}{sup 3} with the slightly higher values from combustion of forest residues. Both mass and total number concentrations were dominated by submicron particles contribution. Elements determined by Particle Induced X-rays Emission (PIXE) analysis (Z>12) contributed to 21-34 % of

  1. Multiobjective Optimization of a Counterrotating Type Pump-Turbine Unit Operated at Turbine Mode

    Directory of Open Access Journals (Sweden)

    Jin-Hyuk Kim

    2014-05-01

    Full Text Available A multiobjective optimization for improving the turbine output and efficiency of a counterrotating type pump-turbine unit operated at turbine mode was carried out in this work. The blade geometry of both the runners was optimized using a hybrid multiobjective evolutionary algorithm coupled with a surrogate model. Three-dimensional Reynolds-averaged Navier-Stokes equations with the shear stress transport turbulence model were discretized by finite volume approximations and solved on hexahedral grids to analyze the flow in the pump-turbine unit. As major hydrodynamic performance parameters, the turbine output and efficiency were selected as objective functions with two design variables related to the hub profiles of both the runner blades. These objectives were numerically assessed at twelve design points selected by Latin hypercube sampling in the design space. Response surface approximation models for the objectives were constructed based on the objective function values at the design points. A fast nondominated sorting genetic algorithm for the local search coupled with the response surface approximation models was applied to determine the global Pareto-optimal solutions. The trade-off between the two objectives was determined and described with respect to the Pareto-optimal solutions. The results of this work showed that the turbine outputs and efficiencies of optimized pump-turbine units were simultaneously improved in comparison to the reference unit.

  2. Field Operations and Enforcement Manual for Air Pollution Control. Volume III: Inspection Procedures for Specific Industries.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume III, explains in detail the following: inspection procedures for specific sources, kraft pulp mills, animal rendering, steel mill furnaces, coking operations, petroleum refineries, chemical plants, non-ferrous smelting and refining, foundries, cement plants, aluminum…

  3. Operation of Wastewater Treatment Plants: A Field Study Training Program. Volume II. Second Edition.

    Science.gov (United States)

    California State Univ., Sacramento. Dept. of Civil Engineering.

    This manual was prepared by experienced wastewater collection system workers to provide a home study course to develop new qualified workers and expand the abilities of existing workers. This volume emphasizes material needed by intermediate-level operators and stresses the operation and maintenance of conventional treatment plants. This volume…

  4. Operation of Wastewater Treatment Plants: A Field Study Training Program. Volume I. Second Edition.

    Science.gov (United States)

    California State Univ., Sacramento. Dept. of Civil Engineering.

    This manual was prepared by experienced wastewater collection system workers to provide a home study course to develop new qualified workers and expand the abilities of existing workers. This volume is directed primarily towards entry-level operators and the operators of ponds, package plants, or small treatment plants. Ten chapters examine the…

  5. Recent trends in operator theory and partial differential equations the Roland Duduchava anniversary volume

    CERN Document Server

    Natroshvili, David; Shargorodsky, Eugene; Wendland, Wolfgang

    2017-01-01

    This volume is dedicated to the eminent Georgian mathematician Roland Duduchava on the occasion of his 70th birthday. It presents recent results on Toeplitz, Wiener-Hopf, and pseudodifferential operators, boundary value problems, operator theory, approximation theory, and reflects the broad spectrum of Roland Duduchava's research. The book is addressed to a wide audience of pure and applied mathematicians.

  6. Field Operations and Enforcement Manual for Air Pollution Control. Volume III: Inspection Procedures for Specific Industries.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume III, explains in detail the following: inspection procedures for specific sources, kraft pulp mills, animal rendering, steel mill furnaces, coking operations, petroleum refineries, chemical plants, non-ferrous smelting and refining, foundries, cement plants, aluminum…

  7. Operation and Maintenance of Wastewater Collection Systems. Volume I. Third Edition. A Field Study Training Program.

    Science.gov (United States)

    California State Univ., Sacramento. Dept. of Civil Engineering.

    Proper installations, inspections, operations, maintenance and repairs of wastewater collection, conveyance and treatment facilities have a significant impact on the operation and maintenance costs, and the effectiveness of these facilities. This manual is the first volume of a two-part program designed to provide wastewater collection system…

  8. An overview of distribution of births in United States hospitals in 2008 with implications for small volume perinatal units in rural hospitals.

    Science.gov (United States)

    Simpson, Kathleen Rice

    2011-01-01

    To evaluate the distribution of births among United States (U.S.) hospitals in 2008 as part of the background for the Association of Women's Health, Obstetric and Neonatal Nurses' Guidelines for Professional Registered Nurse Staffing for Perinatal Units. Descriptive analysis of birth volumes in U.S. hospitals using American Hospital Association Annual Survey: 2008. U.S. hospitals providing obstetric (OB) services were identified based on information in any of three fields: OB services, OB beds, or number of births. Data were verified via telephone and/or website for the top 100 hospitals based on volume, hospitals with "Healthcare System" as part of their names, hospitals reporting births but no OB service, and hospitals reporting births. Hospitals with births were queried regarding nurse staffing. Descriptive statistics were used to analyze data. Approximately 3,265 U.S. hospitals offered OB services in 2008. The top 500 hospitals based on volume (15.3%) accounted for almost one half (47.4%) of births, the top 1,000 for 69.2%, and the remaining 2,265 for 30.8%. Fourteen percent of hospitals with births in 2008 reported discontinuing OB services in 2010, in part due to lack of physician coverage and costs. Most hospitals (n=159, 72.3%) with births routinely maintained two OB-skilled nurses in-house in 2010. U.S. births are unevenly distributed among hospitals; 15% have a disproportionate share of nearly one half of all births. Most hospitals (69.4%) are operating medium- to small-volume OB units. Most hospitals (72.3%) with births annually reported currently meeting minimum staffing guidelines. © 2011 AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses.

  9. Derivation of Plastic Work Rate Done per Unit Volume for Mean Yield Criterion and Its Application

    Institute of Scientific and Technical Information of China (English)

    Dewen ZHAO; Yingjie XIE; Xiaowen WANG; Xianghua LIU

    2005-01-01

    In Haigh Westergaard stress space linear combination of twin shear stress and Tresca yield functions is called the mean yield (MY) criterion. The mathematical relationship of the criterion and its plastic work rate done per unit volume were derived. A generalized worked example of slab forging was analyzed by the criterion and its corresponding plastic work rate done per unit volume. Then, the precision of the solution was compared with those by Mises and Twin shear stress yield criterions, respectively. It turned out that the calculated results by MY criterion were in good agreement with those by Mises criterion.

  10. Fatality trends in United Nations Peacekeeping Operations, 1948-1998.

    Science.gov (United States)

    Seet, B; Burnham, G M

    2000-08-02

    The rising number of deaths among United Nations (UN) peacekeeping forces after the Cold War has made some troop-contributing countries hesitant to participate in peacekeeping operations. While the number and scale of missions have increased, no data have demonstrated a parallel increase in risks to peacekeepers. To determine the association of characteristics of UN peacekeeping operations with risks and mortality rates among UN peacekeeping forces in both the Cold War and post-Cold War periods. Descriptive analysis of 1559 personnel deaths during 49 UN peacekeeping missions from 1948-1998 based on the casualty database maintained by Department of Peacekeeping Operations, UN Headquarters. Number and percentage of deaths by circumstance, total crude death rate, and crude death rate and relative risk of death by circumstance (hostile acts, unintentional violence, and illness or other causes) and time period (Cold War vs post-Cold War), geographic region, and nature of peacekeeping response; and regression analysis of mission variables (strength, duration, and humanitarian mandate) associated with total number of deaths. More deaths have occurred among UN peacekeeping forces in the past decade alone than in the previous 40 years of UN peacekeeping (807 vs 752), but crude death rates did not differ significantly by time period (Cold War vs post-Cold War, 21.8 vs 21. 2 deaths per 10,000 person-years; P =.58), level of peacekeeping response, or for geographic regions other than East Europe and Central America, where rates were lower (PCold War (relative risk [RR] 1. 51; 95% confidence interval [CI], 1.22-1.88), while rates for deaths caused by unintentional violence decreased (RR, 0.79; 95% CI, 0.67-0. 94) but remain high, particularly in the Middle East and Asia (RR, 1. 39; 95% CI, 1.15-1.69). Regression analysis showed a significant association between number of deaths and the strength (PCold War rather than increased RR of death. Post-Cold War peacekeeping personnel

  11. Operations research in intensive care unit management: a literature review.

    Science.gov (United States)

    Bai, Jie; Fügener, Andreas; Schoenfelder, Jan; Brunner, Jens O

    2016-08-12

    The intensive care unit (ICU) is a crucial and expensive resource largely affected by uncertainty and variability. Insufficient ICU capacity causes many negative effects not only in the ICU itself, but also in other connected departments along the patient care path. Operations research/management science (OR/MS) plays an important role in identifying ways to manage ICU capacities efficiently and in ensuring desired levels of service quality. As a consequence, numerous papers on the topic exist. The goal of this paper is to provide the first structured literature review on how OR/MS may support ICU management. We start our review by illustrating the important role the ICU plays in the hospital patient flow. Then we focus on the ICU management problem (single department management problem) and classify the literature from multiple angles, including decision horizons, problem settings, and modeling and solution techniques. Based on the classification logic, research gaps and opportunities are highlighted, e.g., combining bed capacity planning and personnel scheduling, modeling uncertainty with non-homogenous distribution functions, and exploring more efficient solution approaches.

  12. Development and Evaluation of the Habitat Demonstration Unit Medical Operations Workstation and Opportunities for Future Research

    Science.gov (United States)

    Howard, Robert L., Jr.

    2012-01-01

    As NASA develops missions to leave Earth orbit and explore distant destinations (Mars, Moon, Asteroids) it is necessary to rethink human spaceflight paradigms in the life sciences. Standards developed for low earth orbit human spaceflight may not be fully applicable and in-space research may be required to develop new standards. Preventative and emergency medical care may require new capabilities never before used in space. Due to spacecraft volume limitations, this work area may also be shared with various animal and plant life science research. This paper explores the prototype Medical Operations Workstation within the NASA Habitat Demonstration Unit and discusses some of the lessons learned from field analogue missions involving the workstation. Keywords: Exploration, medical, health, crew, injury emergency, biology, animal, plant, science, preventative, emergency.

  13. Experience of operation of the gas turbine units in Russky Island

    Directory of Open Access Journals (Sweden)

    Bibikov Dmitry

    2017-01-01

    Full Text Available In the present article, the heat and power supply system based on the distributed cogeneration and created as part of the APEC Summit and development of the southern Far East is considered. A brief review of the experience of operating the gas turbine units of the Co-generation plant in the Russky Island is given. The output of the heat energy over 2015 reached 142.228 thousands Gcal which is larger than that in 2014 by 18.8 %. The specific reference fuel consumption for electric supply was 272.4 g/(kW*h while for heat supply – 195.8 kg/Gcal. In spite of partial load of the stations with regard to electric and heat energy (volumes of consumptions by the connected consumers is less than designed loads, the indices of reference fuel consumption suggest the efficiency of the generation equipment of co-generation plant.

  14. German Studies in the United States: Assessment and Outlook. Monatshefte Occasional Volume Number 1.

    Science.gov (United States)

    Lohnes, Walter F. W., Ed.; Nollendorfs, Valters, Ed.

    This volume focuses on two principal aspects of German studies in the United States: (1) an assessment of the German-teaching profession from primary to graduate school, with attention to its "raison d'etre" in the present academic, social, and cultural situation, as well as its structures, aims, and personnel; and (2) strategies for survival and…

  15. Atlas of United States Trees, Volume 2: Alaska Trees and Common Shrubs.

    Science.gov (United States)

    Viereck, Leslie A.; Little, Elbert L., Jr.

    This volume is the second in a series of atlases describing the natural distribution or range of native tree species in the United States. The 82 species maps include 32 of trees in Alaska, 6 of shrubs rarely reaching tree size, and 44 more of common shrubs. More than 20 additional maps summarize environmental factors and furnish general…

  16. FOCU:S--future operator control unit: soldier

    Science.gov (United States)

    O'Brien, Barry J.; Karan, Cem; Young, Stuart H.

    2009-05-01

    The U.S. Army Research Laboratory's (ARL) Computational and Information Sciences Directorate (CISD) has long been involved in autonomous asset control, specifically as it relates to small robots. Over the past year, CISD has been making strides in the implementation of three areas of small robot autonomy, namely platform autonomy, Soldier-robot interface, and tactical behaviors. It is CISD's belief that these three areas must be considered as a whole in order to provide Soldiers with useful capabilities. In addressing the Soldier-robot interface aspect, CISD has begun development on a unique dismounted controller called the Future Operator Control Unit: Soldier (FOCU:S) that is based on an Apple iPod Touch. The iPod Touch's small form factor, unique touch-screen input device, and the presence of general purpose computing applications such as a web browser combine to give this device the potential to be a disruptive technology. Setting CISD's implementation apart from other similar iPod or iPhone-based devices is the ARL software that allows multiple robotic platforms to be controlled from a single OCU. The FOCU:S uses the same Agile Computing Infrastructure (ACI) that all other assets in the ARL robotic control system use, enabling automated asset discovery on any type of network. Further, a custom ad hoc routing implementation allows the FOCU:S to communicate with the ARL ad hoc communications system and enables it to extend the range of the network. This paper will briefly describe the current robotic control architecture employed by ARL and provide short descriptions of existing capabilities. Further, the paper will discuss FOCU:S specific software developed for the iPod Touch, including unique capabilities enabled by the device's unique hardware.

  17. Is fumigation enough for air conditioning units in operation theatres and Intensive care units?

    Directory of Open Access Journals (Sweden)

    Anasua Deb

    2016-05-01

    Full Text Available Background: Strict asepsis is necessary in operating theatres (OT and intensive care units (ICU as the patients undergo invasive procedures. The filters of contaminated air conditioning (AC units provide a niche for proliferation of fungi and production of fungal spores. Methods: The routine procedure for maintenance of sterile atmosphere in our hospital, i.e. fumigation and mopping walls with disinfectants often fail to address these fungal spores of the AC filters. We therefore carried out a surveillance of the ACs in ICUs and OTs to find the level of contamination with fungal spores and also to improvise on intervention strategies to tackle the problem. Over 3 months period, 34 ACs from 7 OTs and 2 ICUs were screened by taking 2 swabs from each AC which were then tested for the presence of fungal spores as per standard methods. Results: The contamination rate was 88.2% before fumigation and 76.9% after fumigation. The fungal spore contamination rate was reduced to 20% (1 out of 5 ACs after servicing of the ACs was done. Aspergillus spp. was the most common fungal isolate. Conclusion: Based on the observations, we recommend regular servicing of the ACs as well as wet mopping of the ducts with sporicidal solution at regular intervals. [Int J Res Med Sci 2016; 4(5.000: 1583-1589

  18. Symmetric angular momentum coupling, the quantum volume operator and the 7-spin network: a computational perspective

    CERN Document Server

    Marinelli, Dimitri; Aquilanti, Vincenzo; Anderson, Roger W; Bitencourt, Ana Carla P; Ragni, Mirco

    2014-01-01

    A unified vision of the symmetric coupling of angular momenta and of the quantum mechanical volume operator is illustrated. The focus is on the quantum mechanical angular momentum theory of Wigner's 6j symbols and on the volume operator of the symmetric coupling in spin network approaches: here, crucial to our presentation are an appreciation of the role of the Racah sum rule and the simplification arising from the use of Regge symmetry. The projective geometry approach permits the introduction of a symmetric representation of a network of seven spins or angular momenta. Results of extensive computational investigations are summarized, presented and briefly discussed.

  19. The Future of Information Operations in the United States Army

    Science.gov (United States)

    2007-01-01

    as Marketing Marketing tools and concepts could generate support for coalition military operations just as an advertiser promoting a commercial...military, the advanced application of marketing tools to leverage humanitarian assistance and public affairs within an Information Operations plan

  20. Operation Enduring Freedom. Joint Center for Operational Analysis Journal, Volume 11, Issue 3, Fall 2009

    Science.gov (United States)

    2009-01-01

    leaders at the small-unit level had enough leeway, specialized assets, and fi repower to engage the popu- lation and develop their own intelligence... repower . A TET will not be able to do this. I will not get into the specifi cs here, but believe me when I say the planning prior to the mission being

  1. Influencing Tomorrow: A Study of Emerging Influence Techniques and Their Relevance to United States Information Operations

    Science.gov (United States)

    2015-06-12

    groups and governmental institutions; the possibility of economic loss directed at entrepreneurs; or the prospect of United States undue influence or... INFLUENCING TOMORROW: A STUDY OF EMERGING INFLUENCE TECHNIQUES AND THEIR RELEVANCE TO UNITED STATES INFORMATION OPERATIONS A...

  2. Planning, Designing, Building, and Moving a Large Volume Maternity Service to a New Labor and Birth Unit.

    Science.gov (United States)

    Thompson, Heather; Legorreta, Kimberly; Maher, Mary Ann; Lavin, Melanie M

    day, and optimal operational utility, as anticipated, of a new labor and birth unit in a large volume perinatal service are detailed.

  3. United States Military in Central Asia: Beyond Operation Enduring Freedom

    Science.gov (United States)

    2009-10-23

    Malinowski , advocacy director for Human Rights Watch, stated, “the United States is most effective in promoting liberty around the world when people...26 U.S. President, The National Security Strategy of the United States of America, page? 27 Thomas Malinowski , “Testimony

  4. Operational air quality forecast guidance for the United States

    Science.gov (United States)

    Stajner, Ivanka; Lee, Pius; Tong, Daniel; Pan, Li; McQueen, Jeff; Huang, Jinaping; Djalalova, Irina; Wilczak, James; Huang, Ho-Chun; Wang, Jun; Stein, Ariel; Upadhayay, Sikchya

    2016-04-01

    NOAA provides operational air quality predictions for ozone and wildfire smoke over the United States (U.S.) and predictions of airborne dust over the contiguous 48 states at http://airquality.weather.gov. These predictions are produced using U.S. Environmental Protection Agency (EPA) Community Model for Air Quality (CMAQ) and NOAA's HYSPLIT model (Stein et al., 2015) with meteorological inputs from the North American Mesoscale Forecast System (NAM). The current efforts focus on improving test predictions of fine particulate matter (PM2.5) from CMAQ. Emission inputs for ozone and PM2.5 predictions include inventory information from the U.S. EPA and recently added contributions of particulate matter from intermittent wildfires and windblown dust that rely on near real-time information. Current testing includes refinement of the vertical grid structure in CMAQ and inclusion of contributions of dust transport from global sources into the U.S. domain using the NEMS Global Aerosol Capability (NGAC). The addition of wildfire smoke and dust contributions in CMAQ reduced model underestimation of PM2.5 in summertime. Wintertime overestimation of PM2.5 was reduced by suppressing emissions of soil particles when the terrain is covered by snow or ice. Nevertheless, seasonal biases and biases in the diurnal cycle of PM2.5 are still substantial. Therefore, a new bias correction procedure based on an analog ensemble approach was introduced (Djalalova et al., 2015). It virtually eliminates biases in monthly means or in the diurnal cycle, but it also reduces day-to-day variability in PM2.5 predictions. Refinements to the bias correction procedure are being developed. Upgrades for the representation of wildfire smoke emissions within the domain and from global sources are in testing. Another area of active development includes approaches to scale emission inventories for nitrogen oxides in order to reproduce recent changes observed by the AirNow surface monitoring network and by

  5. Toeplitz Operators on Dirichlet-Type Space of Unit Ball

    Directory of Open Access Journals (Sweden)

    Jin Xia

    2014-01-01

    Full Text Available We construct a function u in L2Bn, dV which is unbounded on any neighborhood of each boundary point of Bn such that Toeplitz operator Tu is a Schatten p-class 0operator on Dirichlet-type space DBn, dV. Then, we discuss some algebraic properties of Toeplitz operators with radial symbols on the Dirichlet-type space DBn, dV. We determine when the product of two Toeplitz operators with radial symbols is a Toeplitz operator. We investigate the zero-product problem for several Toeplitz operators with radial symbols. Furthermore, the corresponding commuting problem of Toeplitz operators whose symbols are of the form ξku is studied, where k ∈ Zn, ξ ∈ ∂Bn, and u is a radial function.

  6. Licensed operating reactors: Status summary report, data as of December 31, 1995. Volume 20

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    The US Nuclear Regulatory Commission`s monthly summary of licensed nuclear power reactor data is based primarily on the operating data report submitted by licensees for each unit. This report is divided into two sections: the first contains summary highlights and the second contains data on each individual unit in commercial operation. Section 1 availability factors, capacity factors, and forced outage rates are simple arithmetic averages. Section 2 items in the cumulative column are generally as reported by the licensees and notes to the use of weighted averages and starting dates other than commercial operation are provided.

  7. Toeplitz Operators with Quasihomogeneous Symbols on the Bergman Space of the Unit Ball

    Directory of Open Access Journals (Sweden)

    Bo Zhang

    2012-01-01

    symbols on the Bergman space of the unit ball equals a Toeplitz operator with quasihomogeneous symbols. We also characterize finite-rank semicommutators or commutators of two Toeplitz operators with quasihomogeneous symbols.

  8. Volume of activity and occupancy rate in intensive care units. Association with mortality.

    Science.gov (United States)

    Iapichino, Gaetano; Gattinoni, Luciano; Radrizzani, Danilo; Simini, Bruno; Bertolini, Guido; Ferla, Luca; Mistraletti, Giovanni; Porta, Francesca; Miranda, Dinis R

    2004-02-01

    Mortality after many procedures is lower in centers where more procedures are done. It is controversial whether this is true for intensive care units, too. We examined the relationship between the volume of activity of intensive care units (ICUs) and mortality by a measure of risk-adjusted volume of activity specific for ICUs. Prospective, multicenter, observational study. Eighty-nine ICUs in 12 European countries. During a 4-month study period, 12,615 patients were enrolled. Demographic and clinical statistics, severity at admission and a score of nursing complexity and workload were collected. Total volume of activity was defined as the number of patients admitted per bed per year, high-risk volume as the number of high-risk patients admitted per bed per year (selected combining of length of stay and severity of illness). A multi-step risk-adjustment process was planned. ICU volume corresponding both to overall [odds ratio (OR) 0.966] and 3,838 high-risk (OR 0.830) patients was negatively correlated with mortality. Relative mortality decreased by 3.4 and 17.0% for every five extra patients treated per bed per year in overall volume and high-risk volume, respectively. A direct relationship was found between mortality and the ICU occupancy rate (OR 1.324 and 1.351, respectively). Intensive care patients, whatever their level of risk, are best treated where more high-risk patients are treated. Moreover, the higher the ICU occupancy rate, the higher is the mortality.

  9. Large-Scale Multi-Resolution Representations for Accurate Interactive Image and Volume Operations

    KAUST Repository

    Sicat, Ronell B.

    2015-11-25

    The resolutions of acquired image and volume data are ever increasing. However, the resolutions of commodity display devices remain limited. This leads to an increasing gap between data and display resolutions. To bridge this gap, the standard approach is to employ output-sensitive operations on multi-resolution data representations. Output-sensitive operations facilitate interactive applications since their required computations are proportional only to the size of the data that is visible, i.e., the output, and not the full size of the input. Multi-resolution representations, such as image mipmaps, and volume octrees, are crucial in providing these operations direct access to any subset of the data at any resolution corresponding to the output. Despite its widespread use, this standard approach has some shortcomings in three important application areas, namely non-linear image operations, multi-resolution volume rendering, and large-scale image exploration. This dissertation presents new multi-resolution representations for large-scale images and volumes that address these shortcomings. Standard multi-resolution representations require low-pass pre-filtering for anti- aliasing. However, linear pre-filters do not commute with non-linear operations. This becomes problematic when applying non-linear operations directly to any coarse resolution levels in standard representations. Particularly, this leads to inaccurate output when applying non-linear image operations, e.g., color mapping and detail-aware filters, to multi-resolution images. Similarly, in multi-resolution volume rendering, this leads to inconsistency artifacts which manifest as erroneous differences in rendering outputs across resolution levels. To address these issues, we introduce the sparse pdf maps and sparse pdf volumes representations for large-scale images and volumes, respectively. These representations sparsely encode continuous probability density functions (pdfs) of multi-resolution pixel

  10. Lung protection: an intervention for tidal volume reduction in a teaching intensive care unit

    Science.gov (United States)

    Briva, Arturo; Gaiero, Cristina

    2016-01-01

    Objective To determine the effect of feedback and education regarding the use of predicted body weight to adjust tidal volume in a lung-protective mechanical ventilation strategy. Methods The study was performed from October 2014 to November 2015 (12 months) in a single university polyvalent intensive care unit. We developed a combined intervention (education and feedback), placing particular attention on the importance of adjusting tidal volumes to predicted body weight bedside. In parallel, predicted body weight was estimated from knee height and included in clinical charts. Results One hundred fifty-nine patients were included. Predicted body weight assessed by knee height instead of visual evaluation revealed that the delivered tidal volume was significantly higher than predicted. After the inclusion of predicted body weight, we observed a sustained reduction in delivered tidal volume from a mean (standard error) of 8.97 ± 0.32 to 7.49 ± 0.19mL/kg (p < 0.002). Furthermore, the protocol adherence was subsequently sustained for 12 months (delivered tidal volume 7.49 ± 0.54 versus 7.62 ± 0.20mL/kg; p = 0.103). Conclusion The lack of a reliable method to estimate the predicted body weight is a significant impairment for the application of a worldwide standard of care during mechanical ventilation. A combined intervention based on education and repeated feedbacks promoted sustained tidal volume education during the study period (12 months). PMID:27925055

  11. Hanford Environmental Information System (HEIS) Operator`s Manual. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Schreck, R.I.

    1991-10-01

    The Hanford Environmental Information System (HEIS) is a consolidated set of automated resources that effectively manage the data gathered during environmental monitoring and restoration of the Hanford Site. The HEIS includes an integrated database that provides consistent and current data to all users and promotes sharing of data by the entire user community. This manual describes the facilities available to the operational user who is responsible for data entry, processing, scheduling, reporting, and quality assurance. A companion manual, the HEIS User`s Manual, describes the facilities available-to the scientist, engineer, or manager who uses the system for environmental monitoring, assessment, and restoration planning; and to the regulator who is responsible for reviewing Hanford Site operations against regulatory requirements and guidelines.

  12. 300-FF-1 Operable Unit physical separation of soils pilot plant study

    Energy Technology Data Exchange (ETDEWEB)

    Freeman-Pollard, J.R.

    1994-01-15

    Alternative Remedial Technologies, Inc. (ART) was selected in a competitive selection process to conduct a pilot study for the physical separation of soils in the North Process Pond of the 300 Area at the Hanford Site. In January 1994, ART mobilized its 15 tons-per-hour pilot plant to the site. The plant was initially staged in a commercial area to allow for pretest inspections and minor modifications. The plant was specifically designed for use as a physical separations unit and consisted of a feed hopper, wet screens, hydrocyclones, as well as settling and dewatering equipment. The plant was supported in the field with prescreening equipment, mobile generators, air compressors, and water storage tanks. The plant was moved into the surface contamination area on March 24, 1994. The testing was conducted during the period March 23, 1994 through April 13, 1994. Two soil types were treated during the testing: a natural soil contaminated with low levels of uranium, cesium, cobalt, and heavy metals, and a natural soil contaminated with a uranium carbonate material that was visually recognizable by the presence of a green sludge material in the soil matrix. The ``green`` material contained significantly higher levels of the same contaminants. Both source materials were treated by the plant in a manner that fed the material, produced clean gravel and sand fractions, and concentrated the contaminants in a sludge cake. Process water was recycled during the operations. The testing was extremely successful in that for both source waste streams, it was demonstrated that volume reductions of greater than 90% could be achieved while also meeting the test performance criteria. The volume reduction for the natural soils averaged a 93.8%, while the ``green`` soils showed a 91.4% volume reduction.

  13. 77 FR 29701 - Impact of Construction (Under a Combined License) of New Nuclear Power Plant Units on Operating...

    Science.gov (United States)

    2012-05-18

    ... a Combined License) of New Nuclear Power Plant Units on Operating Units at Multi-Unit Sites AGENCY... a COL intending to construct and operate new nuclear power plants (NPPs) on multi-unit sites to... Impacts of Construction (under a Combined License) of New Nuclear Power Plants on Operating Units at...

  14. Deduction of plastic work rate per unit volume for unified yield criterion and its application

    Institute of Scientific and Technical Information of China (English)

    ZHAO De-wen; LI Jing; LIU Xiang-hua; WANG Guo-dong

    2009-01-01

    A unified linear expression of plastic work rate per unit volume is deduced from the unified linear yield criterion and the associated flow rule. The expression is suitable for various linear yield loci in the error triangle between Tresca's and twin shear stress yield loci on the π-plane. It exhibits generalization in which the different value of criterion parameter b corresponds to a specific linear formula of plastic work rate per unit volume. Finally, with the unified linear expression of plastic work rate and upper-bound parallel velocity field the strip forging without bulge is successfully analyzed and an analytical result is also obtained. The comparison with traditional solutions shows that when b=1/(1+(√3)) the result is the same as the upper bound result by Mises' yield criterion, and it also is identical to that by slab method with m=1, σ0=0.

  15. 78 FR 16302 - Crystal River Unit 3 Nuclear Generating Plant, Application for Amendment to Facility Operating...

    Science.gov (United States)

    2013-03-14

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Crystal River Unit 3 Nuclear Generating Plant, Application for Amendment to Facility Operating... Operating License No. DPR-72 for the Crystal River Unit 3 Nuclear Generating Plant (CR-3), located in...

  16. Analysis Methods and Models for Small Unit Operations

    Science.gov (United States)

    2006-07-01

    methods are called for. TNO report I TNO-DV 2006 A228 9 /22 Efect Figure I Effect Based Operations framework. In practice, Figure 1 is useful when trying to...11, 111, IV, V Re-establishing communications Transport support (drivers, vehicles) Support to crowd and Riot Control (CRC) operations Support to... communicate opponent opponent intel gewonnen Verkennings- Reconnaissance Waarnemen terrein Observe terrain Inlichtingen over Gathered intel on patrouille

  17. Impact of an electronic health record operating room management system in ophthalmology on documentation time, surgical volume, and staffing.

    Science.gov (United States)

    Sanders, David S; Read-Brown, Sarah; Tu, Daniel C; Lambert, William E; Choi, Dongseok; Almario, Bella M; Yackel, Thomas R; Brown, Anna S; Chiang, Michael F

    2014-05-01

    Although electronic health record (EHR) systems have potential benefits, such as improved safety and quality of care, most ophthalmology practices in the United States have not adopted these systems. Concerns persist regarding potential negative impacts on clinical workflow. In particular, the impact of EHR operating room (OR) management systems on clinical efficiency in the ophthalmic surgery setting is unknown. To determine the impact of an EHR OR management system on intraoperative nursing documentation time, surgical volume, and staffing requirements. For documentation time and circulating nurses per procedure, a prospective cohort design was used between January 10, 2012, and January 10, 2013. For surgical volume and overall staffing requirements, a case series design was used between January 29, 2011, and January 28, 2013. This study involved ophthalmic OR nurses (n = 13) and surgeons (n = 25) at an academic medical center. Electronic health record OR management system implementation. (1) Documentation time (percentage of operating time documenting [POTD], absolute documentation time in minutes), (2) surgical volume (procedures/time), and (3) staffing requirements (full-time equivalents, circulating nurses/procedure). Outcomes were measured during a baseline period when paper documentation was used and during the early (first 3 months) and late (4-12 months) periods after EHR implementation. There was a worsening in total POTD in the early EHR period (83%) vs paper baseline (41%) (P system implementation was associated with worsening of intraoperative nursing documentation time especially in shorter procedures. However, it is possible to implement an EHR OR management system without serious negative impacts on surgical volume and staffing requirements.

  18. Recensione a "Collodi. Edizione Nazionale delle Opere di Carlo Lorenzini. Volume III"

    Directory of Open Access Journals (Sweden)

    Pina Paone

    2013-06-01

    Full Text Available Si presenta il terzo volume della collana Collodi, Edizione Nazionale delle Opere di Carlo Lorenzini, Giunti, Firenze, 2012, con Prefazione di Mario Vargas Llosa e Introduzione di Daniela Marcheschi. Il volume contiene il famosissimo Le Avventure di Pinocchio, sintesi del percorso artistico dello scrittore toscano ed espressione più compiuta della sua abilità e consapevolezza narrativa. La recensione ripercorrerà i tratti dell’opera, inserendola nel generale e più ampio contesto dell’attività letteraria di Collodi.

  19. An Innovative Method for Dynamic Characterization of Fan FilterUnit Operation.

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Tengfang

    2006-12-21

    Fan filter units (FFU) are widely used to deliver re-circulated air while providing filtration control of particle concentration in controlled environments such as cleanrooms, minienvironments, and operating rooms in hospitals. The objective of this paper is to document an innovative method for characterizing operation and control of an individual fan filter unit within its operable conditions. Built upon the draft laboratory method previously published [1] , this paper presents an updated method including a testing procedure to characterize dynamic operation of fan filter units, i.e., steady-state operation conditions determined by varied control schemes, airflow rates, and pressure differential across the units. The parameters for dynamic characterization include total electric power demand, total pressure efficiency, airflow rate, pressure differential across fan filter units, and airflow uniformity.

  20. Microchannel apparatus comprising plural microchannels and methods of conducting unit operations

    Science.gov (United States)

    Wegeng, Robert S [Richland, WA; TeGrotenhuis, Ward E [Kennewick, WA; Whyatt, Greg A [West Richland, WA

    2009-03-10

    Microchannel apparatus comprising a header and plural flow microchannels is described in which orifices connect the header and the flow microchannels. The orifices constrict flow. The ratio of the cross-sectional area of each of the orifices to the cross-sectional area of the flow microchannels connected to the orifices is between 0.0005 and 0.1. Also described is microchannel apparatus for conducting unit operations in which a device comprises two arrays of microchannels, and a unit operation is conducted on a fluid as it passes through the first set of microchannels and into a header where a second unit operation is performed, and then the fluid stream passes into the second array of microchannels where the first unit operation is again performed. Methods of conducting unit operations in the apparatuses are also described.

  1. Survey of fish impingement at power plants in the United States. Volume I. The Great Lakes

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Rajendra K.; Freeman, III, Richard F.

    1977-03-01

    Impingement of fish at cooling-water intakes of 20 power plants located on the Great Lakes has been surveyed and data are presented. Descriptions of site, plant, and intake design and operation are provided. Reports in this volume summarize impingement data for individual plants in tabular and histogram formats. Information was available from differing sources such as the utilities themselves, public documents, regulatory agencies, and others. Thus, the extent of detail in the reports varies greatly from plant to plant. Histogram preparation involved an extrapolation procedure that has inadequacies. The reader is cautioned in the use of information presented in this volume to determine intake-design acceptability or intensity of impacts on ecosystems. No conclusions are presented herein; data comparisons are made in Volume IV.

  2. Survey of fish impingement at power plants in the United States. Volume II. Inland waters

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, III, Richard F.; Sharma, Rajendra K.

    1977-03-01

    Impingement of fish at cooling-water intakes of 33 power plants located on inland waters other than the Great Lakes has been surveyed and data are presented. Descriptions of site, plant, and intake design and operation are provided. Reports in this volume summarize impingement data for individual plants in tabular and histogram formats. Information was available from differing sources such as the utilities themselves, public documents, regulatory agencies, and others. Thus, the extent of detail in the reports varies greatly from plant to plant. Histogram preparation involved an extrapolation procedure that has inadequacies. The reader is cautioned in the use of information presented in this volume to determine intake-design acceptability or intensity of impacts on ecosystems. No conclusions are presented herein; data comparisons are made in Volume IV.

  3. Licensed operating reactors: Status summary report data as of December 31, 1991. Volume 16

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-03-01

    The Nuclear Regulatory Commission`s annual summary of licensed nuclear power reactor data is based primarily on the report of operating data submitted by licensees for each unit for the month of December because that report contains data for the month of December, the year to date (in this case calendar year 1991) and cumulative data, usually from the date of commercial operation. The data is not independently verified, but various computer checks are made. The report is divided into two sections. The first contains summary highlights and the second contains data on each individual unit in commercial operation. Section 1 capacity and availability factors are simple arithmetic averages. Section 2 items in the cumulative column are generally as reported by the licensee and notes as to the use of weighted averages and starting dates other than commercial operation are provided.

  4. Licensed operating reactors. Status summary report data as of 12-31-94: Volume 19

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    The Nuclear Regulatory Commission`s annual summary of licensed nuclear power reactor data is based primarily on the report of operating data submitted by licensees for each unit for the month of December because that report contains data for the month of December, the year to date (in this case calendar year 1994) and cumulative data, usually from the date of commercial operation. The data is not independently verified, but various computer checks are made. The report is divided into two sections. The first contains summary highlights and the second contains data on each individual unit in commercial operation. Section 1 capacity and availability factors are simple arithmetic averages. Section 2 items in the cumulative column are generally as reported by the licensee and notes as to the use of weighted averages and starting dates other than commercial operation are provided.

  5. Proposed Continental Operations Range. United States Air Force.

    Science.gov (United States)

    1974-06-01

    Fallon, Battle Motutain, Francis Peak, and Cedar City. Other COR non-participating ertities to be linked to COR Central to promote cooperation in...qualities worth retain’ng: friendliness, and toleration of privacy. "So it is a valid fear that some of thebe valued traditions will be lost with the...by sheep during the winter months from November 1 to April 30. (;razing units In the Battle Mountain Grazing district of the BL, in the northern part

  6. United States Air Force Role in Mass Atrocity Response Operations

    Science.gov (United States)

    2012-05-17

    through the lens of their own perspective. They cannot view the world objectively because of their own preconceptions : history, prejudices, ideology...initial stages of the genocide. Similarly, the RC-135’s ability to detect and locate those stations would provide the perfect target for strikes having...all levels. Air Force unit exercises would integrate air power, focusing on those specific tasks required in a MARO. These training exercises , in

  7. On Point: The United States Army in Operation Iraqi Freedom

    Science.gov (United States)

    2004-01-01

    Captain Matthew Paul and Sergeant Jose Adorno , Task Force 2-7 IN mortar platoon, walked down the road the unit had used earlier to enter the airport...than 10 seconds later, the ground rumbled with the sound of approaching armor once again, and Captain Paul and Sergeant Adorno turned to move out of...road; Sergeant Adorno sprinted off to the right. Winding through the trees and bushes screening Four Corners, he was back with the mortar platoon in

  8. Parallel Operation Characteristics Analysis of Sewage Source Heat Pump Units in Winter

    Institute of Scientific and Technical Information of China (English)

    庄兆意; 张承虎; 王海燕; 孙德兴

    2010-01-01

    Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi...

  9. Simulation model for wind energy storage systems. Volume II. Operation manual. [SIMWEST code

    Energy Technology Data Exchange (ETDEWEB)

    Warren, A.W.; Edsinger, R.W.; Burroughs, J.D.

    1977-08-01

    The effort developed a comprehensive computer program for the modeling of wind energy/storage systems utilizing any combination of five types of storage (pumped hydro, battery, thermal, flywheel and pneumatic). An acronym for the program is SIMWEST (Simulation Model for Wind Energy Storage). The level of detail of SIMWEST is consistent with a role of evaluating the economic feasibility as well as the general performance of wind energy systems. The software package consists of two basic programs and a library of system, environmental, and load components. Volume II, the SIMWEST operation manual, describes the usage of the SIMWEST program, the design of the library components, and a number of simple example simulations intended to familiarize the user with the program's operation. Volume II also contains a listing of each SIMWEST library subroutine.

  10. Remedial investigation work plan for Bear Creek Valley Operable Unit 1 (S-3 Ponds, Boneyard/Burnyard, Oil Landfarm, Sanitary Landfill 1, and the Burial Grounds, including Oil Retention Ponds 1 and 2) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Volume 1, Main text

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The intent and scope of the work plan are to assemble all data necessary to facilitate selection of remediation alternatives for the sites in Bear Creek Valley Operable Unit 1 (BCV OU 1) such that the risk to human health and the environment is reduced to acceptable levels based on agreements with regulators. The ultimate goal is to develop a final Record Of Decision (ROD) for all of the OUs in BCV, including the integrator OU. However, the initial aim of the source OUs is to develop a ROD for interim measures. For source OUs such as BCV OU 1, data acquisition will not be carried out in a single event, but will be carried out in three stages that accommodate the schedule for developing a ROD for interim measures and the final site-wide ROD. The three stages are as follows: Stage 1, Assemble sufficient data to support decisions such as the need for removal actions, whether to continue with the remedial investigation (RI) process, or whether no further action is required. If the decision is made to continue the RI/FS process, then: Stage 2, Assemble sufficient data to allow for a ROD for interim measures that reduce risks to the human health and the environment. Stage 3, Provide input from the source OU that allows a final ROD to be issued for all OUs in the BCV hydrologic regime. One goal of the RI work plan will be to ensure that sampling operations required for the initial stage are not repeated at later stages. The overall goals of this RI are to define the nature and extent of contamination so that the impact of leachate, surface water runoff, and sediment from the OU I sites on the integrator OU can be evaluated, the risk to human health and the environment can be defined, and the general physical characteristics of the subsurface can be determined such that remedial alternatives can be screened.

  11. Analysis and discretization of the volume penalized Laplace operator with Neumann boundary conditions

    CERN Document Server

    Kolomenskiy, Dmitry; Schneider, Kai

    2014-01-01

    We study the properties of an approximation of the Laplace operator with Neumann boundary conditions using volume penalization. For the one-dimensional Poisson equation we compute explicitly the exact solution of the penalized equation and quantify the penalization error. Numerical simulations using finite differences allow then to assess the discretisation and penalization errors. The eigenvalue problem of the penalized Laplace operator with Neumann boundary conditions is also studied. As examples in two space dimensions, we consider a Poisson equation with Neumann boundary conditions in rectangular and circular domains.

  12. United Nations Operations: Who Should be in Charge?

    Science.gov (United States)

    1994-04-01

    Cold War; Panama, Iraq, and the New World Order, in RIGHT V. MIGHT, supra note 16, at 109, 128; and HANS KELSON, THE LAW OF THE UNITED NATIONS 928...interpretation would also appear to resolve Kelsen’s dilemma (see KELSEN , supra note 35, at 935) with respect to the Korean conflict. Kelsen argues the Security...and Scheffer, supra note 35, at 131. 45. See D. J. HARRIS, CASES AND MATERIAL ON INTERNATIONAL LAW 681 (4th ed. 1991); KELSEN , supra note 35, at 756

  13. Selecting Foreign Languages for United States Army Special Operations Forces

    Science.gov (United States)

    2006-06-16

    Portugal 170,000,000 7 RUSSIAN [RUS] Russia 170,000,000 8 JAPANESE [JPN] Japan 125,000,000 9 GERMAN, STANDARD [GER] Germany 98,000,000 10 CHINESE, WU...took place (Birtle 2004, Ch 2). Operations in Mexico, Cuba, Russia , and the Philippines are examples of US expeditionary forces deployed to areas...Department of the Army civilians, and retirees. The programs available are free of charge and are for either beginners or people seeking to increase or

  14. Operational Encirclements: Can the United States Military Decisively Follow Through?

    Science.gov (United States)

    2009-05-21

    friction that trickles down onto the battlefield. The European theatre during World War II was no different. The failure of American, and British...American and their Allied partners would continue to experience the ill-effects of it right up until the end of the war in the European theatre ...on Friday 27 March 2009 about Operation Anaconda. I used some information from our conversation. The following is verbatim from my monograph, "A

  15. The United States Army Operating Concept, 2016-2028

    Science.gov (United States)

    2010-08-19

    retrograde operations. f. Theater armies may also include a medical command for deployment support that provides health services to Army and other...tenets of jus in bello ,120 discrimination (between combatants and noncombatants), and proportionality in the use of force,121 measured against the...Barracks, PA, 19. (Used with permission.) 119 Biddle, 9. 120 Jus in bello , translated as justice in war, are agreements defining limits on acceptable

  16. Tactical Unit Data and Decision Requirements for Urban Operations

    Science.gov (United States)

    2008-10-01

    decision requirements useful in urban operations. DISCLAIMER: The contents of this report are not to be used for advertising , publication, or...Building Function Verify mosque and identify possi- ble schools or meeting places Identify types of cinema (stage/theatre) or other similar nearby...Determine mosque and residen- tial floor plans Interior layout of cinema and high-rises Layout of power control facilities Improved Dismounted & Mounted

  17. Biota of the 300-FF-1 operable unit. [Westinghouse Hanford Company

    Energy Technology Data Exchange (ETDEWEB)

    Rickard, W.H. Jr.; Fitzner, R.E.; Brandt, C.A.

    1990-10-01

    This report summarizes Task 5a-2 of the Phase I Remedial Investigation -- Operable Unit Characterization of the 300-FF-1 Operable Unit on the Hanford Site, near Richland, Washington. The ultimate goal of Phase I is to determine the nature and extent of the threat to public health and the environment from releases of hazardous substances from the operable unit. The purpose of Task 5a-2 was to determine what species inhabit the 300-FF-1 Operable Unit and how they use the unit. The focus is on those species listed as endangered or threatened, those that are economically important, or those that constitute significant components of the human food chain. 39 refs., 5 figs., 5 tabs.

  18. Ethnomathematics study: uncovering units of length, area, and volume in Kampung Naga Society

    Science.gov (United States)

    Septianawati, T.; Turmudi; Puspita, E.

    2017-02-01

    During this time, mathematics is considered as something neutral and not associated with culture. It can be seen from mathematics learning in the school which adopt many of foreign mathematics learning are considered more advanced (western). In fact, Indonesia is a rich country in cultural diversity. In the cultural activities, there are mathematical ideas that were considered a important thing in the mathematics learning. A study that examines the idea or mathematical practices in a variety of cultural activities are known as ethnomathematics. In Indonesia, there are some ethnic maintain their ancestral traditions, one of them is Kampung Naga. Therefore, this study was conducted in Kampung Naga. This study aims to uncover units of length, area, and volume used by Kampung Naga society. This study used a qualitative approach and ethnography methods. In this research, data collection is done through the principles of ethnography such as observation, interviews, documentation, and field notes. The results of this study are units of length, area, and volume used by Kampung Naga society and its conversion into standard units. This research is expected to give information to the public that mathematics has a relationship with culture and become recommendation to mathematics curriculum in Indonesia.

  19. Operational Optimization of Large-Scale Parallel-Unit SWRO Desalination Plant Using Differential Evolution Algorithm

    Directory of Open Access Journals (Sweden)

    Jian Wang

    2014-01-01

    Full Text Available A large-scale parallel-unit seawater reverse osmosis desalination plant contains many reverse osmosis (RO units. If the operating conditions change, these RO units will not work at the optimal design points which are computed before the plant is built. The operational optimization problem (OOP of the plant is to find out a scheduling of operation to minimize the total running cost when the change happens. In this paper, the OOP is modelled as a mixed-integer nonlinear programming problem. A two-stage differential evolution algorithm is proposed to solve this OOP. Experimental results show that the proposed method is satisfactory in solution quality.

  20. Short-Term, Low-Volume Training Improves Heat Acclimatization in an Operational Context

    Directory of Open Access Journals (Sweden)

    Keyne Charlot

    2017-06-01

    Full Text Available Personnel who travel to areas with a hot climate (WBGT > 27°C may suffer from the heat (physiological strain, thermal discomfort, increased probability of heat illness, making them partially or fully inoperative. Performing physical activities during heat acclimatization is known to improve this process (i.e., improve measures of acclimatization for the same duration of acclimation. However, it is unknown whether such training would be efficient in an operative context, characterized by a high volume of work-related physical activity. Thirty French soldiers (Training group, T performed a short (5 days, progressive, moderate (from three to five 8-min running sets at 50% of the speed at VO2max for 32–56 min aerobic training program upon arriving at their base in United Arab Emirates (~40°C and 12% RH. A control group (30 soldiers; No Training, NT continued to perform their usual outdoor military activities (~6 h.d−1. A field heat stress test (HST; three 8-min running sets at 50% of the speed at VO2max was performed, before and after the heat acclimatization period, to assess physiological and subjective changes. Rectal temperature, heart rate (HR, thermal discomfort at rest and at the end of exercise, rates of perceived exertion (RPE, and sweat loss and osmolality decreased following heat acclimatization in both groups. However, the decreases in the T group were larger than those in the NT group for HR at the end of exercise (−20 ± 13 vs. −13 ± 6 bpm, respectively, p = 0.044, thermal discomfort at rest (−2.6 ± 2.7 vs. −1.4 ± 2.1 cm, respectively, p = 0.013 and at the end of exercise (−2.6 ± 1.9 vs. −1.6 ± 1.7 cm, respectively, p = 0.037 and RPE (−2.3 ± 1.8 vs. −1.3 ± 1.7, respectively, p = 0.035. Thus, we showed that adding short (<60 min, daily, moderate-intensity training sessions during a professional mission in a hot and dry environment accelerated several heat-acclimatization-induced changes at rest and during

  1. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 3: Specifications

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. Volume 3 is a compilation of the construction specifications that will constitute the Title II materials and performance specifications. This volume contains CSI specifications for non-equipment related construction material type items, performance type items, and facility mechanical equipment items. Data sheets are provided, as necessary, which specify the equipment overall design parameters.

  2. Hospital markup and operation outcomes in the United States.

    Science.gov (United States)

    Gani, Faiz; Ejaz, Aslam; Makary, Martin A; Pawlik, Timothy M

    2016-07-01

    Although the price hospitals charge for operations has broad financial implications, hospital pricing is not subject to regulation. We sought to characterize national variation in hospital price markup for major cardiothoracic and gastrointestinal operations and to evaluate perioperative outcomes of hospitals relative to hospital price markup. All hospitals in which a patient underwent a cardiothoracic or gastrointestinal procedure were identified using the Nationwide Inpatient Sample for 2012. Markup ratios (ratio of charges to costs) for the total cost of hospitalization were compared across hospitals. Risk-adjusted morbidity, failure-to-rescue, and mortality were calculated using multivariable, hierarchical logistic regression. Among the 3,498 hospitals identified, markup ratios ranged from 0.5-12.2, with a median markup ratio of 2.8 (interquartile range 2.7-3.9). For the 888 hospitals with extreme markup (greatest markup ratio quartile: markup ratio >3.9), the median markup ratio was 4.9 (interquartile range 4.3-6.0), with 10% of these hospitals billing more than 7 times the Medicare-allowable costs (markup ratio ≥7.25). Extreme markup hospitals were more often large (46.3% vs 33.8%, P markup ratio compared with 19.3% (n = 452) and 6.8% (n = 35) of nonprofit and government hospitals, respectively. Perioperative morbidity (32.7% vs 26.4%, P markup hospitals. There is wide variation in hospital markup for cardiothoracic and gastrointestinal procedures, with approximately a quarter of hospital charges being 4 times greater than the actual cost of hospitalization. Hospitals with an extreme markup had greater perioperative morbidity. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Flight Technical Error Analysis of the SATS Higher Volume Operations Simulation and Flight Experiments

    Science.gov (United States)

    Williams, Daniel M.; Consiglio, Maria C.; Murdoch, Jennifer L.; Adams, Catherine H.

    2005-01-01

    This paper provides an analysis of Flight Technical Error (FTE) from recent SATS experiments, called the Higher Volume Operations (HVO) Simulation and Flight experiments, which NASA conducted to determine pilot acceptability of the HVO concept for normal operating conditions. Reported are FTE results from simulation and flight experiment data indicating the SATS HVO concept is viable and acceptable to low-time instrument rated pilots when compared with today s system (baseline). Described is the comparative FTE analysis of lateral, vertical, and airspeed deviations from the baseline and SATS HVO experimental flight procedures. Based on FTE analysis, all evaluation subjects, low-time instrument-rated pilots, flew the HVO procedures safely and proficiently in comparison to today s system. In all cases, the results of the flight experiment validated the results of the simulation experiment and confirm the utility of the simulation platform for comparative Human in the Loop (HITL) studies of SATS HVO and Baseline operations.

  4. Experimental Study ofa New Operative Procedure for Non-Ischemic Dilated Cardiomyopathy-Overlapping Cardiac Volume Reduction Operation

    Institute of Scientific and Technical Information of China (English)

    罗滨; 孟春营; 温定国; 松居喜朗; 安田庆秀

    2003-01-01

    Objectives To assess anewly devised procedure of cardiac volume reduction without resection of cardiac muscle and evaluated in experimental settings. Methods Ten beagle dogs underwent a rapid pacing leading to heart failure for 3 weeks and received the left ventricular reduction termed overlapping cardiac volume reduction operation (OLCVR) ,which consisted of a longitudinal incision in left ventricular (LV) free wall, sutures of the left marginal to the septal wall, and the right marginal to LV free wall.A slope of the linear preload recruitable stroke work relationship (Mw) , with a X - intercept (Vo) were calculated as the precise indicators of left ventricular systolic function. The constant of isovolumic pressure decay (Tau) and a peak filling rate (PFR) were also calculated as the indicators of LV diastolic function.Results LV end- diastolic dimensions was significantly reduced by OLCVR (43±2 to 25±1; mm).Fractional shortening was significantly improved by OLCVR (11±2 to 30±4;%). Mw (erg* cm-3* 103)was also significantly improved (21±2 to 33 ±3 (p<0. 001 ) ) , whereas Vo, Tau and PFR did not show significant changes. Conclusions The OLCVR significantly increased in the early LV systolic function without detrimental effects on diastolic function. This procedure may become a therapeutic option for end - stage cardiomyopathy.

  5. Analysis of Fukushima unit 2 accident considering the operating conditions of RCIC system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Il, E-mail: sikim@kaeri.re.kr; Park, Jong Hwa; Ha, Kwang Soon; Cho, Song-Won; Song, JinHo

    2016-03-15

    Highlights: • Fukushima unit 2 accident was analyzed using MELCOR 1.8.6. • RCIC operating conditions were assumed and best case was selected. • Effect of RCIC operating condition on accident scenario was found. - Abstract: A severe accident in Fukushima occurred on March 11, 2011 and units 1, 2 and 3 were damaged severely. A tsunami following an earthquake made the supply of electricity power stop, and the safety systems, which use AC or DC power in plants could not operate properly. It is supposed that the degree of core degradation of unit 2 is less serious than in the other plants, and it was estimated that the operation of reactor core isolation cooling (RCIC) system at the initial stage of the accident minimized the core damage through decay heat removal. Although the operating conditions of the RCIC system are not known clearly, it can be important to analyze the accident scenario of unit 2. In this study, best case of the Fukushima unit 2 accident was presented considering the operating conditions of the RCIC system. The effects of operating condition on core degradation and fission product release rate to environment were also examined. In addition, importance of torus room flooding level in the accident analysis was discussed. MELCOR 1.8.6 was used in this research, and the geometries of plant and operating conditions of safety system were obtained from TEPCO through OECD/NEA BSAF Project.

  6. Multi-unit Operations in Non-Nuclear Systems: Lessons Learned for Small Modular Reactors

    Energy Technology Data Exchange (ETDEWEB)

    OHara J. M.; Higgins, J.; DAgostino, A.

    2012-01-17

    The nuclear-power community has reached the stage of proposing advanced reactor designs to support power generation for decades to come. Small modular reactors (SMRs) are one approach to meet these energy needs. While the power output of individual reactor modules is relatively small, they can be grouped to produce reactor sites with different outputs. Also, they can be designed to generate hydrogen, or to process heat. Many characteristics of SMRs are quite different from those of current plants and may be operated quite differently. One difference is that multiple units may be operated by a single crew (or a single operator) from one control room. The U.S. Nuclear Regulatory Commission (NRC) is examining the human factors engineering (HFE) aspects of SMRs to support licensing reviews. While we reviewed information on SMR designs to obtain information, the designs are not completed and all of the design and operational information is not yet available. Nor is there information on multi-unit operations as envisioned for SMRs available in operating experience. Thus, to gain a better understanding of multi-unit operations we sought the lesson learned from non-nuclear systems that have experience in multi-unit operations, specifically refineries, unmanned aerial vehicles and tele-intensive care units. In this paper we report the lessons learned from these systems and the implications for SMRs.

  7. Routine Operation of the Envirodish Unit at the Engineering School of the University of Seville

    Energy Technology Data Exchange (ETDEWEB)

    Silva Perez, M. A.; Ruiz Hernandez, V.; Garcia Granados, F. J.; Lillo Bravo, I.

    2006-07-01

    A 10 kWe Parabolic Dish Stirling engine system was installed at the Seville Engineering School in early 2004. This system is one of the Country Reference Units of the EnviroDish project, consisting in the installation and operation of several such units, based on the EuroDish system, in different countries aimed to gathering reliable O and M data that help to improve and fine-tune the technology. The Seville Country Reference Unit is connected to the grid under the Special Regime for power generation, which establishes credits to power generation based on renewable energy sources. The Seville Country Reference Unit has been in operation since March 2004, accumulating 1671 operation hours and 7.8 MWh of electricity production until August 2005. This paper summarizes the results of 18 months operation, with emphasis on O and M aspects and lessons learned during this period. (Author)

  8. Expiratory flow limitation and operating lung volumes during exercise in older and younger adults.

    Science.gov (United States)

    Smith, Joshua R; Kurti, Stephanie P; Meskimen, Kayla; Harms, Craig A

    2017-02-20

    We determined the effect of aging on expiratory flow limitation (EFL) and operating lung volumes when matched for lung size. We hypothesized that older adults will exhibit greater EFL and increases in EELV during exercise compared to younger controls. Ten older (5M/5W; >60years old) and nineteen height-matched young adults (10M/9W) were recruited. Young adults were matched for%predicted forced vital capacity (FVC) (Y-matched%Pred FVC; n=10) and absolute FVC (Y-matched FVC; n=10). Tidal flow-volume loops were recorded during the incremental exercise test with maximal flow-volume loops measured pre- and post-exercise. Compared to younger controls, older adults exhibited more EFL at ventilations of 26, 35, 51, and 80L/min. The older group had higher end-inspiratory lung volume compared to Y-matched%Pred FVC group during submaximal ventilations. The older group increased EELV during exercise, while EELV stayed below resting in the Y-matched%Pred FVC group. These data suggest older adults exhibit more EFL and increase EELV earlier during exercise compared to younger adults.

  9. Technology used to operate the 300-MW power unit topped with a GTE-110 gas turbine

    Science.gov (United States)

    Berezinets, P. A.; Doverman, G. I.

    2010-09-01

    Results obtained from mathematical simulation of operations for starting the 300-MW power unit topped with a GTE-110 gas turbine installed at the GRES-24 district power station of OAO OGK-6 wholesale power-generating company are described. It is shown that operations on speeding up the steam turbine from a cold state to its idle running mode can be carried out solely by using the heat of exhaust gases from the gas turbine unit without supplying fuel to the boiler.

  10. Modification of Elementary Operational Linear Chains in Compositional Control Unit with Code Sharing

    OpenAIRE

    Aleksander, A.; Larysa, A.; Aleksander, N.

    2009-01-01

    The new design method for compositional microprogram control units with code sharing and elementarization of operational linear chains is proposed. The method targets on reduction in the number of LUT-elements in the combinational part of control unit. Some additional control microinstructions containing codes of the classes of pseudoequivalent chains are used for operational linear chains modification. Proposed method is illustrated by an example. Most desirable GSA characteristics for using...

  11. The US Air Force Aerial Spray Unit: a history of large area disease vector control operations, WWII through Katrina.

    Science.gov (United States)

    Breidenbaugh, Mark; Haagsma, Karl

    2008-01-01

    The US Air Force has had a long history of aerial applications of pesticides to fulfill a variety of missions, the most important being the protection of troops through the minimization of arthropod vectors capable of disease transmission. Beginning in World War II, aerial application of pesticides by the military has effectively controlled vector and nuisance pest populations in a variety of environments. Currently, the military aerial spray capability resides in the US Air Force Reserve (USAFR), which operates and maintains C-130 airplanes capable of a variety of missions, including ultra low volume applications for vector and nuisance pests, as well as higher volume aerial applications of herbicides and oil-spill dispersants. The USAFR aerial spray assets are the only such fixed-wing aerial spray assets within the Department of Defense. In addition to troop protection, the USAFR Aerial Spray Unit has participated in a number of humanitarian/relief missions, most recently in the response to the 2005 Hurricanes Katrina and Rita, which heavily damaged the Gulf Coasts of Louisiana, Mississippi, and Texas. This article provides historical background on the Air Force Aerial Spray Unit and describes the operations in Louisiana in the aftermath of Hurricane Katrina.

  12. Study of the spatial distribution of the absorbed dose in blood volumes irradiated using a teletherapy unit

    Energy Technology Data Exchange (ETDEWEB)

    Goes, E.G., E-mail: eggoes@terra.com.b [Regional Blood Center of Ribeirao Preto, Ribeirao Preto, SP (Brazil); Nicolucci, P.; Nali, I.C. [Physics and Mathematics Department, University of Sao Paulo, Ribeirao Preto, SP (Brazil); Pela, C.A.; Bruco, J.L. [Physics and Mathematics Department, University of Sao Paulo, Ribeirao Preto, SP (Brazil); Center of Instrumentation, Dosimetry and Radioprotection, University of Sao Paulo, Ribeirao Preto, SP (Brazil); Borges, J.C. [Center of Instrumentation, Dosimetry and Radioprotection, University of Sao Paulo, Ribeirao Preto, SP (Brazil); Covas, D.T. [Regional Blood Center of Ribeirao Preto, Ribeirao Preto, SP (Brazil); Center for Cell-Based Therapy, Ribeirao Preto Medical School, University of Sao Paulo, Ribeirao Preto, SP (Brazil)

    2010-06-15

    Blood irradiation can be performed using a dedicated blood irradiator or a teletherapy unit. A thermal device providing appropriate storage conditions during blood components irradiation with a teletherapy unit has been recently proposed. However, the most appropriated volume of the thermal device was not indicated. The goal of this study was to indicate the most appropriated blood volume for irradiation using a teletherapy unit in order to minimize both the dose heterogeneity in the volume and the blood irradiation time using these equipments. Theoretical and experimental methods were used to study the dose distribution in the blood volume irradiated using a linear accelerator and a cobalt-60 therapy machine. The calculation of absorbed doses in the middle plane of cylindrical acrylic volumes was accomplished by a treatment planning system. Experimentally, we also used cylindrical acrylic phantoms and thermoluminescent dosimeters to confirm the calculated doses. The data obtained were represented by isodose curves. We observed that an irradiation volume should have a height of 28 cm and a diameter of 28 cm and a height of 35 cm and a diameter of 35 cm, when the irradiation is to be performed by a linear accelerator and a cobalt-60 teletherapy unit, respectively. Calculated values of relative doses varied from 93% to 100% in the smaller volume, and from 66% to 100% in the largest one. A difference of 5.0%, approximately, was observed between calculated and experimental data. The size of these volumes permits the irradiation of blood bags in only one bath without compromising the homogeneity of the absorbed dose over the irradiated volume. Thus, these irradiation volumes can be recommend to minimize the irradiation time when a teletherapy unit is used to irradiate blood.

  13. Study of the spatial distribution of the absorbed dose in blood volumes irradiated using a teletherapy unit

    Science.gov (United States)

    Góes, E. G.; Nicolucci, P.; Nali, I. C.; Pelá, C. A.; Bruço, J. L.; Borges, J. C.; Covas, D. T.

    2010-06-01

    Blood irradiation can be performed using a dedicated blood irradiator or a teletherapy unit. A thermal device providing appropriate storage conditions during blood components irradiation with a teletherapy unit has been recently proposed. However, the most appropriated volume of the thermal device was not indicated. The goal of this study was to indicate the most appropriated blood volume for irradiation using a teletherapy unit in order to minimize both the dose heterogeneity in the volume and the blood irradiation time using these equipments. Theoretical and experimental methods were used to study the dose distribution in the blood volume irradiated using a linear accelerator and a cobalt-60 therapy machine. The calculation of absorbed doses in the middle plane of cylindrical acrylic volumes was accomplished by a treatment planning system. Experimentally, we also used cylindrical acrylic phantoms and thermoluminescent dosimeters to confirm the calculated doses. The data obtained were represented by isodose curves. We observed that an irradiation volume should have a height of 28 cm and a diameter of 28 cm and a height of 35 cm and a diameter of 35 cm, when the irradiation is to be performed by a linear accelerator and a cobalt-60 teletherapy unit, respectively. Calculated values of relative doses varied from 93% to 100% in the smaller volume, and from 66% to 100% in the largest one. A difference of 5.0%, approximately, was observed between calculated and experimental data. The size of these volumes permits the irradiation of blood bags in only one bath without compromising the homogeneity of the absorbed dose over the irradiated volume. Thus, these irradiation volumes can be recommend to minimize the irradiation time when a teletherapy unit is used to irradiate blood.

  14. 2005 Annual Operations Report for INTEC Operable Unit 3-13, Group 1, Tank Farm Interim Action

    Energy Technology Data Exchange (ETDEWEB)

    D. Shanklin

    2006-07-19

    This annual operations report describes the requirements followed and activities conducted to inspect, monitor, and maintain the items installed during performance of the Waste Area Group 3, Operable Unit 3-13, Group 1, Tank Farm Interim Action, at the Idaho Nuclear Technology and Engineering Center. This report describes inspection and monitoring activities fro the surface-sealed areas within the tank farm, concrete-lined ditches and culverts in and around the tank farm, the lift station, and the lined evaporation pond. These activities are intended to assure that the interim action is functioning adequately to meet the objectives stated in the Operable Unit 3-13, Record of Decision for the Group 1, Tank Farm Interim Action, (DOE/ID-10660) and as amended by the agreement to resolve dispute, which was effective in February 2003.

  15. 2005 Annual Operations Report for INTEC Operable Unit 3-13, Group 1, Tank Farm Interim Action

    Energy Technology Data Exchange (ETDEWEB)

    D. Shanklin

    2006-07-19

    This annual operations report describes the requirements followed and activities conducted to inspect, monitor, and maintain the items installed during performance of the Waste Area Group 3, Operable Unit 3-13, Group 1, Tank Farm Interim Action, at the Idaho Nuclear Technology and Engineering Center. This report describes inspection and monitoring activities fro the surface-sealed areas within the tank farm, concrete-lined ditches and culverts in and around the tank farm, the lift station, and the lined evaporation pond. These activities are intended to assure that the interim action is functioning adequately to meet the objectives stated in the Operable Unit 3-13, Record of Decision for the Group 1, Tank Farm Interim Action, (DOE/ID-10660) and as amended by the agreement to resolve dispute, which was effective in February 2003.

  16. Information as Power: An Anthology of Selected United States Army War College Student Papers. Volume 2

    Science.gov (United States)

    2007-01-01

    DPKO). The DPKO Best Practices Unit ( BPU ) “…has begun to generate the sort of timely, mission-analytic reporting that UN Headquarters, operations...and mission contributors have long needed.”15 “The BPU not only provides a repository for lessons learned but also facilitates their incorporation...the Department of State’s Office of the Coordinator for Stability and Reconstruction (S/CRS), USAID, USIP, CSIS, NIJ, and the UN’s DPKO- BPU . Also

  17. 76 FR 66051 - Availability of the Fiscal Year 2010 United States Special Operations Command (USSOCOM) Inventory...

    Science.gov (United States)

    2011-10-25

    ... of the Secretary Availability of the Fiscal Year 2010 United States Special Operations Command... 2330a of Title 10 United States Code as amended by the National Defense Authorization Act for Fiscal..., Defense Procurement and Acquisition Policy, Office of Strategic Sourcing (DPAP/SS) will make available to...

  18. 77 FR 38274 - Availability of the Fiscal Year 2011 United States Special Operations Command (USSOCOM) Inventory...

    Science.gov (United States)

    2012-06-27

    ... of the Secretary Availability of the Fiscal Year 2011 United States Special Operations Command... 2330a of Title 10, United States Code as amended by the National Defense Authorization Act for Fiscal... Acquisition Policy, Office of Strategic Sourcing (DPAP/SS) will make available to the public the first...

  19. United States Special Operations Command Strategic Issues for the Long War

    Science.gov (United States)

    2006-03-15

    for USSOCOM’s campaign plan. UNITED STATES SPECIAL OPERATIONS COMMAND STRATEGIC ISSUES FOR THE LONG WAR World order is more fundamental and primordial ... Soup to Nuts: Understanding the Elements of the Strategy The United States is a big, lumbering, pluralistic, affluent, liberal, democratic

  20. Relationship of Terminal Duct Lobular Unit Involution of the Breast with Area and Volume Mammographic Densities

    Science.gov (United States)

    Gierach, Gretchen L.; Patel, Deesha A.; Pfeiffer, Ruth M.; Figueroa, Jonine D.; Linville, Laura; Papathomas, Daphne; Johnson, Jason M.; Chicoine, Rachael E.; Herschorn, Sally D.; Shepherd, John A.; Wang, Jeff; Malkov, Serghei; Vacek, Pamela M.; Weaver, Donald L.; Fan, Bo; Mahmoudzadeh, Amir Pasha; Palakal, Maya; Xiang, Jackie; Oh, Hannah; Horne, Hisani N.; Sprague, Brian L.; Hewitt, Stephen M.; Brinton, Louise A.; Sherman, Mark E.

    2016-01-01

    Elevated mammographic density (MD) is an established breast cancer risk factor. Reduced involution of terminal duct lobular units (TDLUs), the histologic source of most breast cancers, has been associated with higher MD and breast cancer risk. We investigated relationships of TDLU involution with area and volumetric MD, measured throughout the breast and surrounding biopsy targets (peri-lesional). Three measures inversely related to TDLU involution (TDLU count/mm2, median TDLU span, median acini count/TDLU) assessed in benign diagnostic biopsies from 348 women, ages 40–65, were related to MD area (quantified with thresholding software) and volume (assessed with a density phantom) by analysis of covariance, stratified by menopausal status and adjusted for confounders. Among premenopausal women, TDLU count was directly associated with percent peri-lesional MD (P-trend=0.03), but not with absolute dense area/volume. Greater TDLU span was associated with elevated percent dense area/volume (P-trendbreast cancer risk suggest that associations of MD with breast cancer may partly reflect amounts of at-risk epithelium. If confirmed, these results could suggest a prevention paradigm based on enhancing TDLU involution and monitoring efficacy by assessing MD reduction. PMID:26645278

  1. Prediction of Long-term Post-operative Testosterone Replacement Requirement Based on the Pre-operative Tumor Volume and Testosterone Level in Pituitary Macroadenoma.

    Science.gov (United States)

    Lee, Cheng-Chi; Chen, Chung-Ming; Lee, Shih-Tseng; Wei, Kuo-Chen; Pai, Ping-Ching; Toh, Cheng-Hong; Chuang, Chi-Cheng

    2015-11-05

    Non-functioning pituitary macroadenomas (NFPAs) are the most prevalent pituitary macroadenomas. One common symptom of NFPA is hypogonadism, which may require long-term hormone replacement. This study was designed to clarify the association between the pre-operative tumor volume, pre-operative testosterone level, intraoperative resection status and the need of long-term post-operative testosterone replacement. Between 2004 and 2012, 45 male patients with NFPAs were enrolled in this prospective study. All patients underwent transsphenoidal surgery. Hypogonadism was defined as total serum testosterone levels of testosterone to patients with defined hypogonadism or clinical symptoms of hypogonadism. Hormone replacement for longer than 1 year was considered as long-term therapy. The need for long-term post-operative testosterone replacement was significantly associated with larger pre-operative tumor volume (p = 0.0067), and lower pre-operative testosterone level (p = 0.0101). There was no significant difference between the gross total tumor resection and subtotal resection groups (p = 0.1059). The pre-operative tumor volume and testosterone level impact post-operative hypogonadism. By measuring the tumor volume and the testosterone level and by performing adequate tumor resection, surgeons will be able to predict post-operative hypogonadism and the need for long-term hormone replacement.

  2. Effect of RCIC Operating Conditions on the Accident Scenario in Fukushima Unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Il; Park, Jong Hwa; Ha, Kwang Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    This study was conducted by using MELCOR 1.8.6. Fukushima unit 2 accident was analyzed using MELCOR in this study, and best estimate scenario with considering RCIC operating conditions was presented. Researches on the boiling water reactor (BWR) plant with reactor core isolation cooling (RCIC) system have been conducted. Research on the RCIC operation in Fukushima unit 2 was also conducted by Sandia National Laboratory. MELCOR analysis of the Fukushima unit 2 accident was conducted in the report and energy balance in wetwell was described by considering RCIC operation. However, the effect of RCIC operation condition on the accident scenario has not been studied. The operating conditions of RCIC system affect the pressures in wetwell and drywell, and the high pressure can make leakage path of fission product from PCV to reactor building. Thus it can be directly related with the amount of fission product which released to environment. In this study, severe accident on Fukushima unit 2 was analyzed considering the operating condition of RCIC system, and best estimated scenario was presented. In addition, the effect of RCIC turbine efficiency on the accident progression was examined. Energy balance in suppression chamber was also considered with discussion on the effect of torus room flooding level. It was found that the operating condition of RCIC turbine not only affects the variation of drywell pressure but also the amount of released fission products to environment. It was also confirmed that the RCIC turbine efficiency in the accident would be less than normal operating condition.

  3. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 4: Project cost estimate

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. This volume represents the total estimated costs for the W113 facility. Operating Contractor Management costs have been incorporated as received from WHC. The W113 Facility TEC is $19.7 million. This includes an overall project contingency of 14.4% and escalation of 17.4%. A January 2001 construction contract procurement start date is assumed.

  4. Feasibility study report for the 200-BP-1 operable unit. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-01

    This feasibility study (FS) examines a range of alternatives and provides recommendations for selecting a preferred altemative for remediating contamination at the 200-BP-1 operable unit. The 200-BP-1 operable unit is located in the center of the Hanford Site along the northern boundary of the 200 East Area. The 241-BY Tank Farm is located immediately to the south of the operable unit. 200-BP-1 is a source operable unit with contaminated soils associated primarily with nine inactive cribs (known as the 216-B cribs). These cribs were used for disposal of low-level radioactive liquid waste from U Plant uranium recovery operations, and waste storage tank condensate from the adjacent 241-BY Tank Farm. The cribs used for disposal of U Plant waste were in operation from 1955--1965, and the cribs used for disposal of tank condensate were in operation from 1965-1975. In addition to the cribs, four unplanned releases of radioactive materials have occurred within the operable unit. Contaminated surface soils associated with the unplanned releases have been consolidated over the cribs and covered with clean soil to reduce contaminant migration and exposure. Discharge of wastes to the cribs has resulted in soil and groundwater contamination. The groundwater is being addressed as part of the 200 East Aggregate Area groundwater operable unit. Contaminated soils at the site can be categorized by the types of contaminants, their distribution in the soil column, and the risk posed by the various potential exposure pathways. Below the clean soil cover, the near surface soils contain low-:levels of contamination with cesium-137, radium-226, strontium-90, thorium-228 and uranium. The lifetime incremental cancer risk associated with these soils if they were exposed at the surface is 9 {times} 10{sup 5}.

  5. Correlation of transrectal and transabodominal ultrasound measurement of transition zone volume with post-operative enucleated adenoma volume in benign prostatic hypertrophy.

    Science.gov (United States)

    Ajayi, Idowu; Aremu, Ademola; Olajide, Abimbola; Bello, Tope; Olajide, Folake; Adetiloye, Victor

    2013-01-01

    Benign prostatic hyperplasia is a common disease of ageing men worldwide. Though transrectal ultrasonography (TRUS) is the standard in most parts of the world in evaluation of benign prostatic hyperplasia (BPH), it is rarely done in some less developed countries because of non availability of appropriate probes and or specialists. Transabdominal ultrasonography (TAUS) remains the mainstay in these areas. Some controversies still exist in literature about the accuracy of TAUS evaluation of prostatic volume in patients with BPH. This study aimed at comparing the transition zone volume estimation of the prostate on transrectal and transabdominal ultrasound with post-operative enucleated adenoma volume in Nigeria patients with BPH and to suggest better predictor of prostate volume in evaluation of BPH. Forty-six (46) patients with lower urinary tract symptoms due to BPH attending the urologic clinic were evaluated ultrasonographically and eventually managed with open surgery (prostatectomy) after due counselling. The post operative samples were weighted using a sensitive top loading weighing balance and converted to volume. Since the specific gravity of the prostate is equivalent to that of water,the weight is the same as volume. Patients' ages ranged between 59 and 90 years with a peak age incidence at seventh decade. Transition Zone (TZ) volume estimation on both transrectal and transabdominal ultrasound showed positive correlation with the post operative enucleated adenoma(r = 0.594, p < 0.001) but the transrectal method was more accurate. There was no significant relationship between the TZ volume and patients' symptoms(r = 0.491, p = 0.007). Both TRUS and TAUS are comparable at TZ volume estimation and therefore TAUS can be utilized in regions where intracavitary probes and or the expertise is/are not available.

  6. Estimates of emergency operating capacity in US manufacturing and nonmanufacturing industries - Volume 1: Concepts and Methodology

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, D.B. (Pacific Northwest Lab., Richland, WA (USA)); Serot, D.E. (D/E/S Research, Richland, WA (USA)); Kellogg, M.A. (ERCE, Inc., Portland, OR (USA))

    1991-03-01

    Development of integrated mobilization preparedness policies requires planning estimates of available productive capacity during national emergency conditions. Such estimates must be developed in a manner to allow evaluation of current trends in capacity and the consideration of uncertainties in various data inputs and in engineering assumptions. This study developed estimates of emergency operating capacity (EOC) for 446 manufacturing industries at the 4-digit Standard Industrial Classification (SIC) level of aggregation and for 24 key nonmanufacturing sectors. This volume lays out the general concepts and methods used to develop the emergency operating estimates. The historical analysis of capacity extends from 1974 through 1986. Some nonmanufacturing industries are included. In addition to mining and utilities, key industries in transportation, communication, and services were analyzed. Physical capacity and efficiency of production were measured. 3 refs., 2 figs., 12 tabs. (JF)

  7. Development and Use of a Web Site with Multimedia Contents as a Complement to Traditional Unit Operations Courses

    Science.gov (United States)

    Tapia, Cristian; Muller, Mauricio; Sapag-Hagar, Jaime; Valenzuela, Fernando; Basualto, Carlos; Abugoch, Lilian

    2005-01-01

    The Unit Operations Laboratory offers 2 courses in unit operations. One is a 2-semester course for chemistry and food engineering students that is more demanding because it considers more unit operations and places more emphasis on solving exercises. The other is a 1-semester course for chemistry and pharmacy students that considers fewer unit…

  8. Results of toxicity tests and chemical analyses conducted on sediments collected from the TNX Outfall Delta Operable Unit, July 1999

    Energy Technology Data Exchange (ETDEWEB)

    Specht, W.L.

    2000-02-11

    In order to provide unit specific toxicity data that will be used to address critical uncertainty in the ecological risk assessment (ERA) for the TNX Outfall Delta Operable Unit (TNXOD OU), sediments were collected from eight locations in the Inner Swamp portion of the operable unit and two unit specific background locations. These samples were analyzed for total mercury, total uranium, and sediment toxicity.

  9. Operating experience feedback report -- turbine-generator overspeed protection systems: Commercial power reactors. Volume 11

    Energy Technology Data Exchange (ETDEWEB)

    Ornstein, H.L.

    1995-04-01

    This report presents the results of the US Nuclear Regulatory Commission`s Office for Analysis and Evaluation of Operational Data (AEOD) review of operating experience of main turbine-generator overspeed and overspeed protection systems. It includes an indepth examination of the turbine overspeed event which occurred on November 9, 1991, at the Salem Unit 2 Nuclear Power Plant. It also provides information concerning actions taken by other utilities and the turbine manufacturers as a result of the Salem overspeed event. AEOD`s study reviewed operating procedures and plant practices. It noted differences between turbine manufacturer designs and recommendations for operations, maintenance, and testing, and also identified significant variations in the manner that individual plants maintain and test their turbine overspeed protection systems. AEOD`s study provides insight into the shortcomings in the design, operation, maintenance, testing, and human factors associated with turbine overspeed protection systems. Operating experience indicates that the frequency of turbine overspeed events is higher than previously thought and that the bases for demonstrating compliance with NRC`s General Design Criterion (GDC) 4, Environmental and dynamic effects design bases, may be nonconservative with respect to the assumed frequency.

  10. United States Department of Energy, Nevada Operations Office, completion report Operation KLAXON, Fiscal Year 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    The U.S. Department of Energy, Nevada Operations Office (DOE/NV), Completion Report provides a summary of activities conducted at the Nevada Test Site (NTS) between October 1, 1992, and September 30, 1993, associated with Operation KLAXON. (In the past, each annual Completion Report dealt with a series of underground nuclear detonations; however, because no nuclear tests were conducted during FY 1993, this Report summarizes continuing nonnuclear and nuclear test readiness activities at the NTS sponsored by DOE/NV.) The report serves as a reference for those involved with the planning and execution of Operation KLAXON and also serves as a planning guide for future operations. Information in the report covers the logistics and management of activities. Scientific information and data associated with NTS activities are presented in technical documents published by participating agencies. In September 1992, Congress legislated a nine-month moratorium on the testing of nuclear weapons. The bill also provided for a resumption of testing (with no more than five tests per year, or a total of 15 during the next three years) in July 1993, and mandated an end to nuclear testing, entirely, by 1996. President Bush signed the bill into law in October 1992.

  11. Effect of the 16-hour work limit on general surgery intern operative case volume: a multi-institutional study.

    Science.gov (United States)

    Schwartz, Samuel I; Galante, Joseph; Kaji, Amy; Dolich, Matthew; Easter, David; Melcher, Marc L; Patel, Kevin; Reeves, Mark E; Salim, Ali; Senagore, Anthony J; Takanishi, Danny M; de Virgilio, Christian

    2013-09-01

    The 80-hour work-week limit for all residents was instituted in 2003 and studies looking at its effect have been mixed. Since the advent of the 16-hour mandate for postgraduate year 1 residents in July 2011, no data have been published regarding the effect of this additional work-hour restriction. To determine whether the 16-hour intern work limit, implemented in July 2011, has adversely affected operative experience. A retrospective review of categorical postgraduate year 1 Accreditation Council for Graduate Medical Education case logs from the intern class (N = 52) (with 16-hour work limit) compared with the 4 preceding years (2007-2010; N = 197) (without 16-hour work limit). A total of 249 categorical general surgery interns from 10 general surgery residency programs in the western United States were included. Total, major, first-assistant, and defined-category case totals. As compared with the preceding 4 years, the 2011-2012 interns recorded a 25.8% decrease in total operative cases (65.9 vs 88.8, P = .005), a 31.8% decrease in major cases (54.9 vs 80.5, P intern era, whereas there was no decrease in trauma, vascular, alimentary, endoscopy, liver, and pancreas cases. The 16-hour work limit for interns, implemented in July 2011, is associated with a significant decrease in categorical intern operative experience. If the 16-hour shift were to be extended to all postgraduate year levels, one can anticipate that additional years of training will be needed to maintain the same operative volume.

  12. Evaluation on Waste Volume and Weight from Decommissioning of Kori Unit 1 Reactor Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yujeong; Lee, Seong-Cheol; Kim, Chang-Lak [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2015-05-15

    In this paper, the concept of cutting reactor vessel and container for decommissioning Kori unit 1 has been investigated. As a result of the investigation, it is found that cutting the reactor vessel into small pieces, especially for upper and bottom heads of the reactor vessel, is more effective to reduce total disposal volume generated from decommissioning. As a part of continuing efforts to prepare shut down of nuclear power plant, several researches have been conducted to establish plans to dispose decommissioning waste from nuclear power plants. When decommissioning nuclear power plant, most of radioactive waste is generated from primary side including a reactor vessel. Radioactive waste amounts generated from decommissioning is significantly affected by several factors, such as dismantling method, waste classification, reactor lifetime, disposal method and etc.

  13. The Applied Meteorology Unit: Nineteen Years Successfully Transitioning Research Into Operations for America's Space Program

    Science.gov (United States)

    Madura, John T.; Bauman, William H., III; Merceret, Francis J.; Roeder, William P.; Brody, Frank C.; Hagemeyer, Bartlett C.

    2011-01-01

    The Applied Meteorology Unit (AMU) provides technology development and transition services to improve operational weather support to America's space program . The AMU was founded in 1991 and operates under a triagency Memorandum of Understanding (MOU) between the National Aeronautics and Space Administration (NASA), the United States Air Force (USAF) and the National Weather Service (NWS) (Ernst and Merceret, 1995). It is colocated with the 45th Weather Squadron (45WS) at Cape Canaveral Air Force Station (CCAFS) and funded by the Space Shuttle Program . Its primary customers are the 45WS, the Spaceflight Meteorology Group (SMG) operated for NASA by the NWS at the Johnson Space Center (JSC) in Houston, TX, and the NWS forecast office in Melbourne, FL (MLB). The gap between research and operations is well known. All too frequently, the process of transitioning research to operations fails for various reasons. The mission of the AMU is in essence to bridge this gap for America's space program.

  14. Prediction of Long-term Post-operative Testosterone Replacement Requirement Based on the Pre-operative Tumor Volume and Testosterone Level in Pituitary Macroadenoma

    OpenAIRE

    Cheng-Chi Lee; Chung-Ming Chen; Shih-Tseng Lee; Kuo-Chen Wei; Ping-Ching Pai; Cheng-Hong Toh; Chi-Cheng Chuang

    2015-01-01

    Non-functioning pituitary macroadenomas (NFPAs) are the most prevalent pituitary macroadenomas. One common symptom of NFPA is hypogonadism, which may require long-term hormone replacement. This study was designed to clarify the association between the pre-operative tumor volume, pre-operative testosterone level, intraoperative resection status and the need of long-term post-operative testosterone replacement. Between 2004 and 2012, 45 male patients with NFPAs were enrolled in this prospective...

  15. Relationships among Ionic Lattice Energies, Molecular (Formula Unit) Volumes, and Thermochemical Radii.

    Science.gov (United States)

    Jenkins, H. Donald B.; Roobottom, Helen K.; Passmore, Jack; Glasser, Leslie

    1999-08-01

    The linear generalized equation described in this paper provides a further dimension to the prediction of lattice potential energies/enthalpies of ionic solids. First, it offers an alternative (and often more direct) approach to the well-established Kapustinskii equation (whose capabilities have also recently been extended by our recent provision of an extended set of thermochemical radii). Second, it makes possible the acquisition of lattice energy estimates for salts which, up until now, except for simple 1:1 salts, could not be considered because of lack of crystal structure data. We have generalized Bartlett's correlation for MX (1:1) salts, between the lattice enthalpy and the inverse cube root of the molecular (formula unit) volume, such as to render it applicable across an extended range of ionic salts for the estimation of lattice potential energies. When new salts are synthesized, acquisition of full crystal structure data is not always possible and powder data provides only minimal structural information-unit cell parameters and the number of molecules per cell. In such cases, lack of information about cation-anion distances prevents use of the Kapustinskii equation to predict the lattice energy of the salt. However, our new equation can be employed even when the latter information is not available. As is demonstrated, the approach can be utilized to predict and rationalize the thermochemistry in topical areas of synthetic inorganic chemistry as well as in emerging areas. This is illustrated by accounting for the failure to prepare diiodinetetrachloroaluminum(III), [I(2)(+)][AlCl(4)(-)] and the instability of triiodinetetrafluoroarsenic(III), [I(3)(+)][AsF(6)(-)]. A series of effective close-packing volumes for a range of ions, which will be of interest to chemists, as measures of relative ionic size and which are of use in making our estimates of lattice energies, is generated from our approach.

  16. Man-hour Estimation Model based on Standard Operation Unit for Flexible Manufacturing System

    Directory of Open Access Journals (Sweden)

    Ye Zhenggeng

    2017-01-01

    Full Text Available In flexible manufacturing system, the estimation of man-hour is a difficult problem because of its production-diversity. To explore a more effective method, this paper tried to estimate man-hour from the perspective of operation`s character by establishing standard operation unit (SOU in this paper. A method of parameterizing the SOU is proposed, and a new man-hour estimation model is established on the basis of SOU. At last, this paper verified the effectiveness of this method by the operation of large-scale welding parts.

  17. Development of in-situ product removal strategies in biocatalysis applying scaled-down unit operations

    DEFF Research Database (Denmark)

    Heintz, Søren; Börner, Tim; Ringborg, Rolf Hoffmeyer

    2017-01-01

    An experimental platform based on scaled-down unit operations combined in a plug-and-play manner enables easy and highly flexible testing of advanced biocatalytic process options such as in-situ product removal (ISPR) process strategies. In such a platform it is possible to compartmentalize...... different process steps while operating it as a combined system, giving the possibility to test and characterize the performance of novel process concepts and biocatalysts with minimal influence of inhibitory products. Here the capabilities of performing process development by applying scaled-down unit......-automatically characterize ω-transaminases in a scaled-down packed-bed reactor (PBR) module, showing MPPA as a strong inhibitor. To overcome the inhibition, a two-step liquid-liquid extraction (LLE) ISPR concept was tested using scaled-down unit operations combined in a plug-and-play manner. Through the tested ISPR concept...

  18. Trends in Pediatric Surgery Operative Volume among Residents and Fellows: Improving the Experience for All.

    Science.gov (United States)

    Talutis, Stephanie; McAneny, David; Chen, Catherine; Doherty, Gerard; Sachs, Teviah

    2016-06-01

    The ACGME requires general surgery residents (GSR) to perform 20 pediatric surgery cases as part of the total 750 cases before graduation. We queried the ACGME General Surgery (1999 to 2014) and Pediatric Surgery (2003 to 2014) Case Logs for all pediatric operations performed during training. Means (±SD) and medians (10(th):90(th) percentiles) were compared, and R(2) was calculated for all trends. The number of pediatric surgery fellows (PSF) increased 63% (23 to 39; R(2) = 0.82), while GSR numbers increased 12% (989 to 1,105; R(2) = 0.77). Total and average pediatric surgery case volume for GSR decreased from 39,309 to 32,156 (R(2) = 0.90) and 39.7 ± 13 to 29.1 ± 10 (R(2) = 0.91), respectively. Meanwhile, average PSF case volume increased from 980 ± 208 to 1,137 ± 202 (R(2) = 0.83). These trends persisted for inguinal/umbilical hernia (GSR 22.1 ± 13 to 15.6 ± 10; R(2) = 0.93; PSF 90.5 ± 17.6 to 104.4 ± 20.7; R(2) = 0.34), pyloric stenosis (GSR 3.9 ± 3 to 2.8 ± 3; R(2) = 0.60; PSF 29.6 ± 15 to 39.7 ± 16.8; R(2) = 0.69), and intestinal atresia (GSR 1.3 ± 2 to 1.1 ± 2; R(2) = 0.34; PSF 4.3 ± 4 to 11.8 ± 8; R(2) = 0.21). The mean number of GSR pediatric operations diminished for both junior (37.1 ± 20 to 27.3 ± 16; R(2) = 0.88) and chief (2.6 ± 5 to 1.7 ± 5; R(2) = 0.75) years. Teaching cases in pediatric surgery decreased at all levels. Although the percentage of GSR teaching cases performed during chief years fell modestly (6.6% to 4.7%; R(2) = 0.53), median teaching cases dropped from 2 (0:11 [10(th):90(th) percentiles]) to zero (0:0 [10(th):90(th) percentiles]). Mean PSF teaching cases declined (100.7 ± 396 to 44.5 ± 42; R(2) = 0.72), while the percentage of operations that were teaching cases decreased more sharply (10.3% to 3.5%; R(2) = 0.82). Total pediatric surgery cases and PSF operative volume have increased, while GSR operative volume has decreased. Opportunities may exist to increase resident participation while

  19. Office for Analysis and Evaluation of Operational Data. 1992 annual report: Nonreactors: Volume 7, No. 2

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-01

    The annual report of the US Nuclear Regulatory Commission`s Office for Analysis and Evaluation of Operational Data (AEOD) is devoted to the activities performed during 1992. The report is published in two separate parts. NUREG-1272, Vol. 7, No. 1, covers power reactors and presents an overview of the operating experience of the nuclear power industry from the NRC perspective, including comments about the trends of some key performance measures. The report also includes the principal findings and issues identified in AEOD studies over the past year and summarizes information from such sources as licensee event reports, diagnostic evaluations, and reports to the NRC`s Operations Center. NUREG-1272, Vol. 7, No. 2, covers nonreactors and presents a review of the events and concerns during 1992 associated with the use of licensed material in nonreactor applications, such as personnel overexposures and medical misadministrations. Both reports also contain a discussion of the Incident Investigation Team program and summarize both the Incident Investigation Team and Augmented Inspection Team reports. Each volume contains a list of the AEOD reports issued for 1981--1992.

  20. Office for Analysis and Evaluation of Operational Data 1996 annual report. Volume 10, Number 1: Reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    This annual report of the US Nuclear Regulatory Commission`s Office for Analysis and Evaluation of Operational Data (AEOD) describes activities conducted during 1996. The report is published in three parts. NUREG-1272, Vol. 10, No. 1, covers power reactors and presents an overview of the operating experience of the nuclear power industry from the NRC perspective, including comments about trends of some key performance measures. The report also includes the principal findings and issues identified in AEOD studies over the past year and summarizes information from such sources as licensee event reports and reports to the NRC`s Operations Center. NUREG-1272, Vol. 10, No. 2, covers nuclear materials and presents a review of the events and concerns during 1996 associated with the use of licensed material in nonreactor applications, such as personnel overexposures and medical misadministrations. Both reports also contain a discussion of the Incident Investigation Team program and summarize both the Incident Investigation Team and Augmented Inspection Team reports. Each volume contains a list of the AEOD reports issued from CY 1980 through 1996. NUREG-1272, Vol. 10, No. 3, covers technical training and presents the activities of the Technical Training Center in support of the NRC`s mission in 1996.

  1. Volume totalizers analysis of pipelines operated by TRANSPETRO National Operational Control Center; Analise de totalizadores de volume em oleodutos operados pelo Centro Nacional de Controle e Operacao da TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Aramaki, Thiago Lessa; Montalvao, Antonio Filipe Falcao [Petrobras Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil); Marques, Thais Carrijo [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2012-07-01

    This paper aims to present the results and methodology in the analysis of differences in volume totals used in systems such as batch tracking and leak detection of pipelines operated by the National Center for Operational Control (CNCO) at TRANSPETRO. In order to optimize this type of analysis, software was developed to acquisition and processing of historical data using the methodology developed. The methodology developed takes into account the particularities encountered in systems operated by TRANSPETRO, more specifically, by CNCO. (author)

  2. Operable Unit 3-13, Group 3, Other Surface Soils (Phase I) Remedial Action Report

    Energy Technology Data Exchange (ETDEWEB)

    L. Davison

    2007-07-31

    This Remedial Action Report summarizes activities undertaken to remediate the Operable Unit 3-13, Group 3, Other Surface Soils, Phase I sites at the Idaho Nuclear Technology and Engineering Center at the Idaho National Laboratory Site. The 10 sites addressed in this report were defined in the Operable Unit 3-13 Record of Decision and subsequent implementing documents. This report concludes that remediation requirements and cleanup goals established for these 10 sites have been accomplished and are hereafter considered No Action or No Further Action sites.

  3. Qualitative risk assessment for the 100-KR-4 groundwater operable unit

    Energy Technology Data Exchange (ETDEWEB)

    Biggerstaff, R.L.

    1994-06-30

    This report provides the qualitative risk assessment (QRA) for the 100-KR-4 groundwater operable unit at the US Department of Energy`s (DOE) Hanford Site in southeastern Washington State. The extent of the groundwater beneath the 100 K Area is defined in the Remedial Investigation/Feasibility Study Work Plan for the 100-KR-4 Operable Unit (DOE-RL 1992a). The QRA is an evaluation or risk using a limited amount of data and a predefined set of human and environmental exposure scenarios and is not intended to replace or be a substitute for a baseline risk assessment.

  4. Operable Unit 3-13, Group 7, SFE-20 Hot Waste Tank System Remedial Action Request

    Energy Technology Data Exchange (ETDEWEB)

    L. Davison

    2009-06-30

    This Remedial Action Report summarizes activities undertaken to remediate the Operable Unit 3-13, Group 7, SFE-20 Hot Waste Tank System at the Idaho Nuclear Technology and Engineering Center at the Idaho National Laboratory Site. The site addressed in this report was defined in the Operable Unit 3-13 Record of Decision and subsequent implementing documents. This report concludes that remediation requirements and cleanup goals established for the site have been accomplished and is hereafter considered a No Further Action site.

  5. Operable Unit 3-13, Group 7, SFE-20 Hot Waste Tank System Remedial Action Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee Davison

    2009-06-30

    This Remedial Action Report summarizes activities undertaken to remediate the Operable Unit 3-13, Group 7, SFE-20 Hot Waste Tank System at the Idaho Nuclear Technology and Engineering Center at the Idaho National Laboratory Site. The site addressed in this report was defined in the Operable Unit 3-13 Record of Decision and subsequent implementing documents. This report concludes that remediation requirements and cleanup goals established for the site have been accomplished and is hereafter considered a No Further Action site.

  6. Structural characterization and condition for measurement statistics preservation of a unital quantum operation

    Science.gov (United States)

    Lee, Kai-Yan; Fung, Chi-Hang Fred; Chau, H. F.

    2013-05-01

    We investigate the necessary and sufficient condition for a convex cone of positive semidefinite operators to be fixed by a unital quantum operation ϕ acting on finite-dimensional quantum states. By reducing this problem to the problem of simultaneous diagonalization of the Kraus operators associated with ϕ, we can completely characterize the kinds of quantum states that are fixed by ϕ. Our work has several applications. It gives a simple proof of the structural characterization of a unital quantum operation that acts on finite-dimensional quantum states—a result not explicitly mentioned in earlier studies. It also provides a necessary and sufficient condition for determining what kind of measurement statistics is preserved by a unital quantum operation. Finally, our result clarifies and extends the work of Størmer by giving a proof of a reduction theorem on the unassisted and entanglement-assisted classical capacities, coherent information, and minimal output Renyi entropy of a unital channel acting on a finite-dimensional quantum state.

  7. NUMATH: a nuclear-material-holdup estimator for unit operations and chemical processes

    Energy Technology Data Exchange (ETDEWEB)

    Krichinsky, A.M.

    1983-02-01

    A computer program, NUMATH (Nuclear Material Holdup Estimator), has been developed to estimate compositions of materials in vessels involved in unit operations and chemical processes. This program has been implemented in a remotely operated nuclear fuel processing plant. NUMATH provides estimates of the steady-state composition of materials residing in process vessels until representative samples can be obtained and chemical analyses can be performed. Since these compositions are used for inventory estimations, the results are determined for the cataloged in container-oriented files. The estimated compositions represent materials collected in applicable vessels - including consideration for materials previously acknowledged in these vessels. The program utilizes process measurements and simple performance models to estimate material holdup and distribution within unit operations. In simulated run-testing, NUMATH typically produced estimates within 5% of the measured inventories for uranium and within 8% of the measured inventories for thorium during steady-state process operation.

  8. Liquid phase methanol LaPorte process development unit: Modification, operation, and support studies

    Energy Technology Data Exchange (ETDEWEB)

    1991-02-02

    The primary focus of this Process Development Unit operating program was to prepare for a confident move to the next scale of operation with a simplified and optimized process. The main purpose of these runs was the evaluation of the alternate commercial catalyst (F21/0E75-43) that had been identified in the laboratory under a different subtask of the program. If the catalyst proved superior to the previous catalyst, then the evaluation run would be continued into a 120-day life run. Also, minor changes were made to the Process Development Unit system to improve operations and reliability. The damaged reactor demister from a previous run was replaced, and a new demister was installed in the intermediate V/L separator. The internal heat exchanger was equipped with an expansion loop to relieve thermal stresses so operation at higher catalyst loadings and gas velocities would be possible. These aggressive conditions are important for improving process economics. (VC)

  9. Toeplitz Operators on the Weighted Bergman Space over the Two-Dimensional Unit Ball

    Directory of Open Access Journals (Sweden)

    Alma García

    2015-01-01

    Full Text Available We extend the known results on commutative Banach algebras generated by Toeplitz operators with radial quasi-homogeneous symbols on the two-dimensional unit ball. Spherical coordinates previously used hid a possibility to detect an essentially wider class of symbols that can generate commutative Banach Toeplitz operator algebras. We characterize these new algebras describing their properties and, under a certain extra condition, construct the corresponding Gelfand theory.

  10. Analysis of United States Marine Corps Operations in Support of Humanitarian Assistance and Disaster Relief

    Science.gov (United States)

    2013-12-01

    unit (MEU), Bangladesh Cyclone Sidr, Operation Sea Angel II, Haiti earthquake 2010, Operation Unified Response, Great East Japan earthquake and...with respect to the conduct of HA/DR missions. We have collected data for the 2007 cyclone on the southwest coast of Bangladesh, the 2010 Haiti ...responded to the 2007 cyclone in Bangladesh, the 2010 Haiti earthquake, and the 2011 Japanese earthquake and subsequent tsunami, respectively. These

  11. Mortality on grower/finisher-only swine operations in the United States

    Directory of Open Access Journals (Sweden)

    Losinger W.C.

    1999-01-01

    Full Text Available For 53 grower/finisher-only swine operations that participated in the United States National Animal Health Monitoring System 1995 National Swine Study, mortality among finisher pigs ranged from 0 to 12.0% over a 6-month period. Twenty-six (49.1% had 2% mortality. Nine (17.0% operations experienced >4% mortality. Fisher's exact test revealed that operations with all-in all-out management were significantly more likely to have 1 grower/finisher pig came from another source. Larger operations (where >900 pigs entered the grower/finisher phase practiced all-in, all-out management more frequently than smaller operations, and had a lower mean percent mortality than smaller operations. Diagnosis of Salmonella in finisher pigs performed at a laboratory or by a veterinarian in the 12 months prior to interview was associated with both increased percent mortality and increased percent mortality per day.

  12. Design of optimal operating conditions of simulated moving bed adsorptive separation units

    Energy Technology Data Exchange (ETDEWEB)

    Storti, G. (Univ. degli Studi di Padova (Italy)); Baciocchi, R.; Mazzotti, M.; Morbidelli, M. (Politecnico di Milano (Italy). Dipt. di Chimica Fisica Applicata)

    1995-01-01

    The design of the optimal operating conditions for simulated moving bed (SMB) adsorptive separation units is considered. A procedure for the a priori selection of the operating conditions to achieve an assigned separation requirement is developed in the frame of equilibrium theory for the equivalent four section countercurrent unit, using a model where the adsorption equilibria are described through the constant selectivity stoichiometric model, while both mass transfer resistance and axial dispersion are neglected. The space of the operating parameters, i.e. the mass flow rate ratios m[sub j], is divided in regions with different separation regimes. Curves at constant outlets purity and recovery are drawn in the (m[sub 2],m[sub 3]) plane. The introduction of three performance parameters, desorbent requirement, adsorbent requirement, and productivity, allows the development of a procedure for the design of optimal operating conditions. This procedure is completed, accounting for the effect of the switching time on the separation performances, with a detailed model of the SMB unit, considering both axial dispersion and mass transfer resistance. This result constitutes a useful tool for determining the range of operating conditions to achieve an assigned separation requirement and then for selecting the optimal operating condition within this range.

  13. 40 CFR 62.15145 - What are the operating practice requirements for my municipal waste combustion unit?

    Science.gov (United States)

    2010-07-01

    ... requirements for my municipal waste combustion unit? 62.15145 Section 62.15145 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Good Combustion Practices: Operating Requirements § 62.15145 What are the operating practice requirements for my municipal waste combustion unit? (a) You...

  14. Changes in Stroke Volume Induced by Lung Recruitment Maneuver Predict Fluid Responsiveness in Mechanically Ventilated Patients in the Operating Room.

    Science.gov (United States)

    Biais, Matthieu; Lanchon, Romain; Sesay, Musa; Le Gall, Lisa; Pereira, Bruno; Futier, Emmanuel; Nouette-Gaulain, Karine

    2017-02-01

    Lung recruitment maneuver induces a decrease in stroke volume, which is more pronounced in hypovolemic patients. The authors hypothesized that the magnitude of stroke volume reduction through lung recruitment maneuver could predict preload responsiveness. Twenty-eight mechanically ventilated patients with low tidal volume during general anesthesia were included. Heart rate, mean arterial pressure, stroke volume, and pulse pressure variations were recorded before lung recruitment maneuver (application of continuous positive airway pressure of 30 cm H2O for 30 s), during lung recruitment maneuver when stroke volume reached its minimal value, and before and after volume expansion (250 ml saline, 0.9%, infused during 10 min). Patients were considered as responders to fluid administration if stroke volume increased greater than or equal to 10%. Sixteen patients were responders. Lung recruitment maneuver induced a significant decrease in mean arterial pressure and stroke volume in both responders and nonresponders. Changes in stroke volume induced by lung recruitment maneuver were correlated with those induced by volume expansion (r = 0.56; P recruitment maneuver predicted fluid responsiveness with a sensitivity of 88% (95% CI, 62 to 98) and a specificity of 92% (95% CI, 62 to 99). Pulse pressure variations more than 6% before lung recruitment maneuver discriminated responders with a sensitivity of 69% (95% CI, 41 to 89) and a specificity of 75% (95% CI, 42 to 95). The area under receiver operating curves generated for changes in stroke volume induced by lung recruitment maneuver (0.96; 95% CI, 0.81 to 0.99) was significantly higher than that for pulse pressure variations (0.72; 95% CI, 0.52 to 0.88; P recruitment maneuver could predict preload responsiveness in mechanically ventilated patients in the operating room.

  15. Orchard Business Management. Unit II. Management and Analysis of the Orchard Operation.

    Science.gov (United States)

    Mullinix, Shauna K.

    This guide is intended for use in providing in-depth formal classroom and on-site instruction in the principles of business and financial management as they apply to operating and managing orchards. Designed to be used with an accompanying Orchard Business Management Record Book, this unit is devoted to management and analysis of an orchard…

  16. Hydrologic resources management program and underground test area operable unit fy 1997

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D. F., LLNL

    1998-05-01

    This report present the results of FY 1997 technical studies conducted by the Lawrence Livermore National Laboratory (LLNL) as part of the Hydrology and Radionuclide Migration Program (HRMP) and Underground Test Area Operable Unit (UGTA). The HRMP is sponsored by the US Department of Energy to assess the environmental (radiochemical and hydrologic) consequences of underground nuclear weapons testing at the Nevada Test Site.

  17. China's first large-scale MA production unit operational in Shanxi

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ Abrainchild of researchers of the CAS Institute of Coal Chemistry, a production unit capable of turning out 20,000 tons of maleic anhydride (MA) per year, the largest of its kind in China, has come into operation recently at the Shanxi Regent Taiming Chemical Co Ltd in Taiyuan, capital of north China's Shanxi Province.

  18. Predicting performance and situation awareness of robot operators in complex situations by unit task tests

    NARCIS (Netherlands)

    Mioch, T.; Smets, N.J.J.M.; Neerincx, M.A.

    2012-01-01

    Human-in-the-loop field tests of human-robot operations in high-demand situations provide serious constraints with respect to costs and control. A set of relatively simple unit tasks might be used to do part of the testing and to establish a benchmark for human-robot performance and situation awaren

  19. Liquid phase methanol LaPorte process development unit: Modification, operation, and support studies

    Energy Technology Data Exchange (ETDEWEB)

    1991-02-02

    This report consists of Detailed Data Acquisition Sheets for Runs E-6 and E-7 for Task 2.2 of the Modification, Operation, and Support Studies of the Liquid Phase Methanol Laporte Process Development Unit. (Task 2.2: Alternate Catalyst Run E-6 and Catalyst Activity Maintenance Run E-7).

  20. Ambiguity in Units and the Referents: Two Cases in Rational Number Operations

    Science.gov (United States)

    Rathouz, Margaret

    2010-01-01

    I explore the impact of ambiguous referral to the unit on understanding of decimal and fraction operations during episodes in two different mathematics courses for pre-service teachers (PSTs). In one classroom, the instructor introduces a rectangular area diagram to help the PSTs visualize decimal multiplication. A transcript from this classroom…

  1. Orchard Business Management. Unit II. Management and Analysis of the Orchard Operation.

    Science.gov (United States)

    Mullinix, Shauna K.

    This guide is intended for use in providing in-depth formal classroom and on-site instruction in the principles of business and financial management as they apply to operating and managing orchards. Designed to be used with an accompanying Orchard Business Management Record Book, this unit is devoted to management and analysis of an orchard…

  2. Predicting performance and situation awareness of robot operators in complex situations by unit task tests

    NARCIS (Netherlands)

    Mioch, T.; Smets, N.J.J.M.; Neerincx, M.A.

    2012-01-01

    Human-in-the-loop field tests of human-robot operations in high-demand situations provide serious constraints with respect to costs and control. A set of relatively simple unit tasks might be used to do part of the testing and to establish a benchmark for human-robot performance and situation awaren

  3. Use of the LITEE Lorn Manufacturing Case Study in a Senior Chemical Engineering Unit Operations Laboratory

    Science.gov (United States)

    Abraham, Nithin Susan; Abulencia, James Patrick

    2011-01-01

    This study focuses on the effectiveness of incorporating the Laboratory for Innovative Technology and Engineering Education (LITEE) Lorn Manufacturing case into a senior level chemical engineering unit operations course at Manhattan College. The purpose of using the case study is to demonstrate the relevance of ethics to chemical engineering…

  4. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 1, Operations

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The Monitoring division is primarily responsible for the coordination and direction of: Aerial measurements to delineate the footprint of radioactive contaminants that have been released into the environment. Monitoring of radiation levels in the environment; Sampling to determine the extent of contaminant deposition in soil, water, air and on vegetation; Preliminary field analyses to quantify soil concentrations or depositions; and Environmental and personal dosimetry for FRMAC field personnel, during a Consequence Management Response Team (CMRT) and Federal Radiological Monitoring and Assessment Center (FRMAC) response. Monitoring and sampling techniques used during CM/FRMAC operations are specifically selected for use during radiological emergencies where large numbers of measurements and samples must be acquired, analyzed, and interpreted in the shortest amount of time possible. In addition, techniques and procedures are flexible so that they can be used during a variety of different scenarios; e.g., accidents involving releases from nuclear reactors, contamination by nuclear waste, nuclear weapon accidents, space vehicle reentries, or contamination from a radiological dispersal device. The Monitoring division also provides technicians to support specific Health and Safety Division activities including: The operation of the Hotline; FRMAC facility surveys; Assistance with Health and Safety at Check Points; and Assistance at population assembly areas which require support from the FRMAC. This volume covers deployment activities, initial FRMAC activities, development and implementation of the monitoring and assessment plan, the briefing of field teams, and the transfer of FRMAC to the EPA.

  5. Qualitative risk assessment for the 100-HR-3 groundwater operable unit

    Energy Technology Data Exchange (ETDEWEB)

    Vukelich, S.E. [Golder Associates, Inc., Richland, WA (United States)

    1994-09-22

    This report provides the qualitative risk assessment for the 100-HR-3 operable unit on the Hanford Reservation. 100-HR-3 is a ground water unit. The purpose of the QRA at the 100-HR-3 operable unit is to focus on a predefined set of human and environmental exposure scenarios in order to provides sufficient information that will assist the Tri-Party signatories (Washington State Department of Ecology, EPA and US DOE) in making defensible decisions on the necessity of Interim Remedial Measures. Frequent- and occasional-use exposure scenarios are evaluated in the human health risk assessment to provide bounding estimates of risk. The ecological risk assessment consists of an evaluation of the risks to riparian and aquatic receptors which live in or near the Columbia River.

  6. Final Report - Advanced MEA's for Enhanced Operating Conditions, Amenable to High Volume Manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Debe, Mark K.

    2007-09-30

    This report summarizes the work completed under a 3M/DOE contract directed at advancing the key fuel cell (FC) components most critical for overcoming the polymer electrolyte membrane fuel cell (PEMFC) performance, durability & cost barriers. This contract focused on the development of advanced ion exchange membranes & electrocatalysts for PEMFCs that will enable operation under ever more demanding automotive operating conditions & the use high volume compatible processes for their manufacture. Higher performing & more durable electrocatalysts must be developed for PEMFCs to meet the power density & lifetime hours required for FC vehicles. At the same time the amount of expensive Pt catalyst must be reduced to lower the MEA costs. While these two properties are met, the catalyst must be made resistant to multiple degradation mechanisms to reach necessary operating lifetimes. In this report, we present the work focused on the development of a completely new approach to PEMFC electrocatalyts, called nanostructured thin film (NSTF) catalysts. The carbon black supports are eliminated with this new approach which eliminates the carbon corrosion issue. The thin film nature of the catalyst significantly improves its robustness against dissolution & grain growth, preserving the surface area. Also, the activity of the NSTF for oxygen reduction is improved by over 500% compared to dispersed Pt catalyts. Finally, the process for fabricating the NSTF catalysts is consistent with high volume roll-good manufacturing & extremely flexible towards the introduction of new catalyst compositions & structures. This report documents the work done to develop new multi-element NSTF catalysts with properties that exceed pure Pt, that are optimized for use with the membranes discussed below, & advance the state-of-the-art towards meeting the DOE 2010 targets for PEMFC electrocatalysts. The work completed advances the understanding of the NSTF catalyst technology, identifies new NSTF

  7. Annual Summary Report Calendar Year 2000 for the 100-HR-3, 100-KR-4, and 100-NR-2 Operable Units and Pump-and-Treat Operations

    Energy Technology Data Exchange (ETDEWEB)

    G. B. Mitchem

    2001-08-22

    This annual progress and performance evaluation report discusses the groundwater remedial actions in the 100 Area, including the interim actions at the 100-HR-3 and 100-KR-4 Operable Units, and also discusses the expedited response action in the 100-NR-2 operable unit.

  8. Limited field investigation report for the 100-HR-3 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    This limited field investigation (LFI) was conducted to assess the applicability of interim remedial measures (IRM) for reducing human health and environmental risks within the 100-HR-3 Groundwater Operable Unit. The 100-HR-3 Operable Unit is comprised of three subareas; the 100 D Area, the 100 H Area and those portions of the 600 Area between the two reactor areas. The operable unit is one of seven operable units associated with the 100 D and H Areas. Operable units 100-DR-1, 100-DR-2, 100-DR-3, 100-HR-1, 100-HR-2 and 100-IU-4 address contaminant sources while 100-HR-3 addresses contamination present in the underlying groundwater. The primary method of field investigation used during this LFI was the installation and sampling of monitoring wells. Samples were collected from the groundwater and soils, and submitted for laboratory analysis. Boreholes were surveyed for radiological contamination using downhole geophysical techniques to further delineate the locations and levels of contaminants. All samples were screened to ascertain the presence of volatile organic compounds and radionuclides. Analytical data were subjected to validation; all round one, two and three and a minimum of 10% of round four data associated with the LFI were validated. A screening method was used to identify contaminants of potential concern (COPC). This screening method eliminated from further consideration, constituents that were below background. Constituents which are considered non-toxic to humans were eliminated from the human health evaluation. Data consistency and blank contamination were also evaluated in the screening process. These COPC were then evaluated further in the qualitative risk assessment (QRA). A human health QRA was performed using conservative (maximum equilibrated contaminant levels from the LFI) analyses.

  9. Soil washing physical separations test procedure - 300-FF-1 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    Belden, R.D.

    1993-10-08

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The {open_quotes}Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,{close_quotes} Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the {open_quotes}300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,{close_quotes} (DOE-RL 1993).

  10. X-ray powder diffraction characterization of the large-volume unit cell of the M8 murataite polytype

    OpenAIRE

    MAKI, Ryosuke S. S.; Morgan, Peter E. D.; Suzuki, Yoshikazu

    2016-01-01

    We have used conventional X-ray powder diffraction to study one of the largest volume inorganic mixed oxide unit-supercell structures done so far. This necessitated some small-angle X-ray scattering-like observations at low angles from

  11. NUMERICAL RESEARCH ON WATER GUIDE BEARING OF HYDRO-GENERATOR UNIT USING FINITE VOLUME METHOD

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    With the consideration of the geometry of tilting pad journal bearing, a new form of the Reynolds equation was derived in this article. The film thickness, the squeeze motion of the journal and the rotation motion of the pad were explicitly contained in the equation. Based on this equation, together with the equilibrium equation of pad pivot, the water guide bearing used in the Gezhouba 10 F hydro-generator unit was numerically researched. The new Reynolds equation for the lubricating film was solved using Finite Volume (FV) discretization, Successive Over-Relaxation (SOR) iteration method and C++ code are included. According to the numerical solution, and the stability of the film and the influences of the film thickness, the journal squeeze effect and the pad rotation effect on film force were discussed. The results indicate that the squeeze effect can not be neglected, although the rotation effect is negligible for both low-speed and high-speed bearings, so the computing time could be greatly reduced.

  12. Remedial investigation/feasibility study work plan for the 100-KR-4 operable unit, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    1992-09-01

    Four areas of the Hanford Site (the 100, 200, 300, and 1100 Areas) have been included on the US Environmental Protection Agency`s (EPA`s) National Priorities List (NPL) under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). This work plan and the attached supporting project plans establish the operable unit setting and the objectives, procedures, tasks, and schedule for conducting the CERCLA remedial investigation/feasibility study (RI/FS) for the 100-KR-4 operable unit. The 100-K Area consists of the 100-KR-4 groundwater operable unit and three source operable units. The 100-KR-4 operable unit includes all contamination found in the aquifer soils and water beneath the 100-K Area. Source operable units include facilities and unplanned release sites that are potential sources of contamination.

  13. Scale-4 Analysis of Pressurized Water Reactor Critical Configurations: Volume 2-Sequoyah Unit 2 Cycle 3

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, S.M.

    1995-01-01

    The requirements of ANSI/ANS 8.1 specify that calculational methods for away-from-reactor criticality safety analyses be validated against experimental measurements. If credit for the negative reactivity of the depleted (or spent) fuel isotopics is desired, it is necessary to benchmark computational methods against spent fuel critical configurations. This report summarizes a portion of the ongoing effort to benchmark away-from-reactor criticality analysis methods using critical configurations from commercial pressurized-water reactors. The analysis methodology selected for all the calculations reported herein is based on the codes and data provided in the SCALE-4 code system. The isotopic densities for the spent fuel assemblies in the critical configurations were calculated using the SAS2H analytical sequence of the SCALE-4 system. The sources of data and the procedures for deriving SAS2H input parameters are described in detail. The SNIKR code module was used to extract the necessary isotopic densities from the SAS2H results and provide the data in the format required by the SCALE criticality analysis modules. The CSASN analytical sequence in SCALE-4 was used to perform resonance processing of the cross sections. The KENO V.a module of SCALE-4 was used to calculate the effective multiplication factor (k{sub eff}) of each case. The SCALE-4 27-group burnup library containing ENDF/B-IV (actinides) and ENDF/B-V (fission products) data was used for all the calculations. This volume of the report documents the SCALE system analysis of three reactor critical configurations for the Sequoyah Unit 2 Cycle 3. This unit and cycle were chosen because of the relevance in spent fuel benchmark applications: (1) the unit had a significantly long downtime of 2.7 years during the middle of cycle (MOC) 3, and (2) the core consisted entirely of burned fuel at the MOC restart. The first benchmark critical calculation was the MOC restart at hot, full-power (HFP) critical conditions. The

  14. Trends in operative experience of pediatric surgical residents in the United States and Canada.

    Science.gov (United States)

    Fingeret, Abbey L; Stolar, Charles J H; Cowles, Robert A

    2013-01-01

    Expansion of the number of training programs in pediatric surgery occurred from 2003 through 2010. We sought to determine the effect of program expansion on case volume and distribution of operative experience. Public domain data on pediatric surgery resident summary statistics available from the Accreditation Council for Graduate Medical Education (ACGME) from July 2003 through June 2010 were analyzed. Total case volume as primary surgeon or teaching assistant, mean case volume per resident, standard deviation, mode, minimum, and maximum number of cases per resident were evaluated. Mean total cases per resident, minimally invasive laparoscopic and thoracoscopic cases, and requisite cases as defined by the ACGME categories of: tumor, important pediatric surgical, and neonatal cases were analyzed by a Cuzick Wilcoxon-type nonparametric trend statistic using a significance level of 0.05. Skew was assessed by Pearson coefficient with levels of -0.5 to 0.5 defining a parametric distribution. The number of pediatric surgical training residents increased by 42% during the years reported, from 24 to 34. No statistically significant difference was found in the mean number of total cases or requisite cases per resident. The mean volume of minimally invasive procedures increased significantly. Case volume per resident was non-parametrically distributed with increasing positive skew over time. The increase in number of pediatric surgical resident training positions has not adversely affected overall operative experience or exposure to highly specialized requisite cases, on average. The increasing positive skew of total and index cases, however, suggests that variability between programs in case exposure is increasing over time. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Performance study of a heat recovery tower with synthetic (polyurethane) flow channels to operate in a solar desalination unit

    OpenAIRE

    Frederico Pinheiro Rodrigues

    2010-01-01

    Because of the lack of drinkable water in various semi-arid regions and the necessary use of renewable energies, the present work presents a performance study of a heat recovery tower to operate in a solar desalination unit for decentralized water production. The solar desalination unit has two parts: a heating unit and a desalination unit.This work presents the field results with a desalination tower with synthetic (polyurethane) flow channels. The tower operation consists of the heating ...

  16. The relationship between in-hospital mortality, readmission into the intensive care nursing unit and/or operating theatre and nurse staffing levels.

    Science.gov (United States)

    Diya, Luwis; Van den Heede, Koen; Sermeus, Walter; Lesaffre, Emmanuel

    2012-05-01

      The aim of this article was to assess the relationship between (1) in-hospital mortality and/or (2) unplanned readmission to intensive care units or operating theatre and nurse staffing variables.   Adverse events are used as surrogates for patient safety in nurse staffing and patient safety research. A single adverse event cannot adequately capture the multi-dimensional attributes of patient safety; hence, there is a need to consider composite measures. Unplanned readmission into the postoperative Intensive Care nursing unit and/or operating Theatre and in-hospital mortality can be viewed as measures that incorporate the effects of several adverse events.   We conducted a Bayesian multilevel analysis on a subset of the 2003 Belgian Hospital Discharge and Nursing Minimum Data sets. The sample included 9054 patients who underwent coronary artery bypass surgery or heart valve procedures from 28 Belgian acute hospitals. Two proxies of patient safety were considered, namely postoperative in-hospital mortality in the first postoperative intensive care unit and unplanned readmission into the intensive care and/or operating theatre (including mortality beyond the first postoperative intensive care unit) after the first-operative intensive care nursing unit.   There is an association between in-hospital mortality and/or unplanned readmissions and nurse staffing levels, but the relationship is moderated by volume and severity of illness respectively. In addition, the relationship differs between the two endpoints.   Higher nurse staffing levels on postoperative general nursing cardiac surgery units protected patients from unplanned readmission to intensive care units or operating theatre and in-hospital mortality. © 2011 Blackwell Publishing Ltd.

  17. An Automatic Uav Mapping System for Supporting un (united Nations) Field Operations

    Science.gov (United States)

    Choi, K.; Cheon, J. W.; Kim, H. Y.; Lee, I.

    2016-06-01

    The United Nations (UN) has performed field operations worldwide such as peacekeeping or rescue missions. When such an operation is needed, the UN dispatches an operation team usually with a GIS (Geographic Information System) customized to a specific operation. The base maps for the GIS are generated mostly with satellite images which may not retain a high resolution and the current situation. To build an up-to-date high resolution map, we propose a UAV (unmanned aerial vehicle) based automatic mapping system, which can operate in a fully automatic way from the data acquisition of sensory data to the data processing for the generation of the geospatial products such as a mosaicked orthoimage of a target area. In this study, we analyse the requirements for UN field operations, suggest a UAV mapping system with an operation scenario, and investigate the applicability of the system. With the proposed system, we can construct a tailored GIS with up-to-date and high resolution base maps for a specific operation efficiently.

  18. An analysis of post-traumatic stress symptoms in United States Air Force drone operators.

    Science.gov (United States)

    Chappelle, Wayne; Goodman, Tanya; Reardon, Laura; Thompson, William

    2014-06-01

    Remotely piloted aircraft (RPA), commonly referred to as "drones," have emerged over the past decade as an innovative warfighting tool. Given there is a paucity of empirical research assessing drone operators, the purpose of this study was to assess for the prevalence of PTSD symptoms among this cohort. Of the 1084 United States Air Force (USAF) drone operators that participated, a total of 4.3% endorsed a pattern of symptoms of moderate to extreme level of severity meeting criteria outlined in the Diagnostic and Statistical Manual of Mental Disorders-4th edition. The incidence of PTSD among USAF drone operators in this study was lower than rates of PTSD (10-18%) among military personnel returning from deployment but higher than incidence rates (less than 1%) of USAF drone operators reported in electronic medical records. Although low PTSD rates may be promising, limitations to this study are discussed.

  19. Comparative analysis of operational forecasts versus actual weather conditions in airline flight planning, volume 2

    Science.gov (United States)

    Keitz, J. F.

    1982-01-01

    The impact of more timely and accurate weather data on airline flight planning with the emphasis on fuel savings is studied. This volume of the report discusses the results of Task 2 of the four major tasks included in the study. Task 2 compares various catagories of flight plans and flight tracking data produced by a simulation system developed for the Federal Aviation Administrations by SRI International. (Flight tracking data simulate actual flight tracks of all aircraft operating at a given time and provide for rerouting of flights as necessary to resolve traffic conflicts.) The comparisons of flight plans on the forecast to flight plans on the verifying analysis confirm Task 1 findings that wind speeds are generally underestimated. Comparisons involving flight tracking data indicate that actual fuel burn is always higher than planned, in either direction, and even when the same weather data set is used. Since the flight tracking model output results in more diversions than is known to be the case, it was concluded that there is an error in the flight tracking algorithm.

  20. ECR-driven multicusp H^- volume source operated in pulsed or cw mode

    Science.gov (United States)

    Svarnas, Panayiotis

    2005-10-01

    Electron cyclotron resonance (ECR) driven multicusp H^- volume hybrid source [1, 2] operates in continuous (cw) or pulsed microwave (2.45 GHz) mode up to 3 kW. The hydrogen plasma is produced between 1 and 7 mTorr by seven elementary ECR sources housed in the magnetic multipole chamber ``Camembert III'' [3]. This ECR configuration could be applied both to accelerator and fusion ion sources. Negative ion or electron extracted currents and plasma characteristics are studied in both modes with electrical measurements, electrostatic probe and photodetachment. The role of the plasma electrode bias in the values of the extracted currents is major. H^- current is maximized for a bias voltage close to plasma potential. An optimum pressure at 4-5 mTorr yields enhanced H^- density in the center of the chamber, under cw regime. Finally, the post-discharge formation of H^-, in the pulsed mode, is observed. [1] A.A. Ivanov Jr., C. Rouille, M. Bacal, Y. Arnal, S. Bechu, J. Pelletier, Rev. Sci. Instrum. 75(5), 1750 (2004) [2] M. Bacal, A.A. Ivanov Jr., C. Rouille, P. Svarnas, S. Bechu, J. Pelletier, AIP Conf. Proc. No 763 (Kiev, Ukraine) (2004) [3] C. Courteille, A.M. Bruneteau, M. Bacal, Rev. Sci. Instrum. 66(3), 2533 (1995)

  1. Correlators of left charges and weak operators in finite volume chiral perturbation theory

    Science.gov (United States)

    Hernández, Pilar; Laine, Mikko

    2003-01-01

    We compute the two-point correlator between left-handed flavour charges, and the three-point correlator between two left-handed charges and one strangeness violating DeltaI = 3/2 weak operator, at next-to-leading order in finite volume SU(3)L × SU(3)R chiral perturbation theory, in the so-called epsilon-regime. Matching these results with the corresponding lattice measurements would in principle allow to extract the pion decay constant F, and the effective chiral theory parameter g27, which determines the Delta I = 3/2 amplitude of the weak decays K to pipi as well as the kaon mixing parameter BK in the chiral limit. We repeat the calculations in the replica formulation of quenched chiral perturbation theory, finding only mild modifications. In particular, a properly chosen ratio of the three-point and two-point functions is shown to be identical in the full and quenched theories at this order.

  2. Scale-4 Analysis of Pressurized Water Reactor Critical Configurations: Volume 3-Surry Unit 1 Cycle 2

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, S.M.

    1995-01-01

    The requirements of ANSI/ANS 8.1 specify that calculational methods for away-from-reactor criticality safety analyses be validated against experimental measurements. If credit for the negative reactivity of the depleted (or spent) fuel isotopics is desired, it is necessary to benchmark computational methods against spent fuel critical configurations. This report summarizes a portion of the ongoing effort to benchmark away-from-reactor criticality analysis methods using selected critical configurations from commercial pressurized-water reactors. The analysis methodology selected for all the calculations in this report is based on the codes and data provided in the SCALE-4 code system. The isotopic densities for the spent fuel assemblies in the critical configurations were calculated using the SAS2H analytical sequence of the SCALE-4 system. The sources of data and the procedures for deriving SAS2H input parameters are described in detail. The SNIKR code module was used to extract the necessary isotopic densities from the SAS2H results and to provide the data in the format required by the SCALE criticality analysis modules. The CSASN analytical sequence in SCALE-4 was used to perform resonance processing of the cross sections. The KENO V.a module of SCALE-4 was used to calculate the effective multiplication factor (k{sub eff}) of each case. The SCALE-4 27-group burnup library containing ENDF/B-IV (actinides) and ENDF/B-V (fission products) data was used for all the calculations. This volume of the report documents the SCALE system analysis of two reactor critical configurations for Surry Unit 1 Cycle 2. This unit and cycle were chosen for a previous analysis using a different methodology because detailed isotopics from multidimensional reactor calculations were available from the Virginia Power Company. These data permitted a direct comparison of criticality calculations using the utility-calculated isotopics with those using the isotopics generated by the SCALE-4

  3. Utility FGD Survey, January--December 1989. Volume 2, Design performance data for operating FGD systems, Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Hance, S.L.; McKibben, R.S.; Jones, F.M. [IT Corp., Cincinnati, OH (United States)

    1992-03-01

    The Utility flue gas desulfurization (FGD) Survey report, which is generated by a computerized data base management system, represents a survey of operational and planned domestic utility flue gas desulfurization (FGD) systems. It summarizes information contributed by the utility industry, system and equipment suppliers, system designers, research organizations, and regulatory agencies. The data cover system design, fuel characteristics, operating history, and actual system performance. Also included is a unit-by-unit discussion of problems and solutions associated with the boilers, scrubbers, and FGD systems. The development status (operational, under construction, or in the planning stages), system supplier, process, waste disposal practice, and regulatory class are tabulated alphabetically by utility company.

  4. Utility FGD Survey, January--December 1989. Volume 2, Design performance data for operating FGD systems, Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Hance, S.L.; McKibben, R.S.; Jones, F.M. [IT Corp., Cincinnati, OH (United States)

    1992-03-01

    The Utility flue gas desulfurization (FGD) Survey report, which is generated by a computerized data base management system, represents a survey of operational and planned domestic utility flue gas desulfurization (FGD) systems. It summarizes information contributed by the utility industry, system and equipment suppliers, system designers, research organizations, and regulatory agencies. The data cover system design, fuel characteristics, operating history, and actual system performance. Also included is a unit-by-unit discussion of problems and solutions associated with the boilers, scrubbers, and FGD systems. The development status (operational, under construction, or in the planning stages), system supplier, process, waste disposal practice, and regulatory class are tabulated alphabetically by utility company.

  5. Groundwater Monitoring Plan for the Reactor Technology Complex Operable Unit 2-13

    Energy Technology Data Exchange (ETDEWEB)

    Richard P. Wells

    2007-03-23

    This Groundwater Monitoring Plan describes the objectives, activities, and assessments that will be performed to support the on-going groundwater monitoring requirements at the Reactor Technology Complex, formerly the Test Reactor Area (TRA). The requirements for groundwater monitoring were stipulated in the Final Record of Decision for Test Reactor Area, Operable Unit 2-13, signed in December 1997. The monitoring requirements were modified by the First Five-Year Review Report for the Test Reactor Area, Operable Unit 2-13, at the Idaho National Engineering and Environmental Laboratory to focus on those contaminants of concern that warrant continued surveillance, including chromium, tritium, strontium-90, and cobalt-60. Based upon recommendations provided in the Annual Groundwater Monitoring Status Report for 2006, the groundwater monitoring frequency was reduced to annually from twice a year.

  6. Final Report - Advanced MEA's for Enhanced Operating Conditions, Amenable to High Volume Manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Debe, Mark K.

    2007-09-30

    This report summarizes the work completed under a 3M/DOE contract directed at advancing the key fuel cell (FC) components most critical for overcoming the polymer electrolyte membrane fuel cell (PEMFC) performance, durability & cost barriers. This contract focused on the development of advanced ion exchange membranes & electrocatalysts for PEMFCs that will enable operation under ever more demanding automotive operating conditions & the use high volume compatible processes for their manufacture. Higher performing & more durable electrocatalysts must be developed for PEMFCs to meet the power density & lifetime hours required for FC vehicles. At the same time the amount of expensive Pt catalyst must be reduced to lower the MEA costs. While these two properties are met, the catalyst must be made resistant to multiple degradation mechanisms to reach necessary operating lifetimes. In this report, we present the work focused on the development of a completely new approach to PEMFC electrocatalyts, called nanostructured thin film (NSTF) catalysts. The carbon black supports are eliminated with this new approach which eliminates the carbon corrosion issue. The thin film nature of the catalyst significantly improves its robustness against dissolution & grain growth, preserving the surface area. Also, the activity of the NSTF for oxygen reduction is improved by over 500% compared to dispersed Pt catalyts. Finally, the process for fabricating the NSTF catalysts is consistent with high volume roll-good manufacturing & extremely flexible towards the introduction of new catalyst compositions & structures. This report documents the work done to develop new multi-element NSTF catalysts with properties that exceed pure Pt, that are optimized for use with the membranes discussed below, & advance the state-of-the-art towards meeting the DOE 2010 targets for PEMFC electrocatalysts. The work completed advances the understanding of the NSTF catalyst technology, identifies new NSTF

  7. The reliability analysis of a separated, dual fail operational redundant strapdown IMU. [inertial measurement unit

    Science.gov (United States)

    Motyka, P.

    1983-01-01

    A methodology for quantitatively analyzing the reliability of redundant avionics systems, in general, and the dual, separated Redundant Strapdown Inertial Measurement Unit (RSDIMU), in particular, is presented. The RSDIMU is described and a candidate failure detection and isolation system presented. A Markov reliability model is employed. The operational states of the system are defined and the single-step state transition diagrams discussed. Graphical results, showing the impact of major system parameters on the reliability of the RSDIMU system, are presented and discussed.

  8. Aquatic studies at the 100-HR-3 and 100-NR-1 operable units

    Energy Technology Data Exchange (ETDEWEB)

    Cushing, C.E.

    1993-04-01

    Pacific Northwest Laboratory initiated a program to characterize selected aquatic biological populations to determine (1) existing levels of inorganic chemical and radionuclide contamination, and (2) the populations` suitability as indicators of chemical releases during cleanup activities at the US Department of Energy`s Hanford Site. Following work plans for the ground-water operable units, lower trophic levels in the aquatic habitat (periphyton and caddisfly larvae) were evaluated for contaminants at the 100-HR-3 Operable Unit and 100-NR-1 Operable Unit. The results were evaluated to determine the need for further sampling. If the results showed no significant contamination compared to upriver levels, sampling would be discontinued. The periphyton community appears to be suitable for determining contamination levels. Baseline concentrations for stable chromium were established and will be useful for comparing samples collected when contaminant release is expected. Concentrations of {sup 60}Co, {sup 90}Sr, and {sup 137}Cs in periphyton were essentially below detectable limits, which will also make this community useful in detecting potential releases of radionuclides during cleanup activities. Levels for both stable chromium and radionuclides were essentially below detection limits for caddisfly larvae. Thus, these organisms may be used to monitor suspected contaminant releases from cleanup activities; if concentrations exceed detection limits, they may be related to these activities. Two candidate threatened and endangered species of molluscs occur in the Hanford Reach of the Columbia River. These are the shortface lanx (Fisherola nuttalli), which is a Washington State candidate species, and the Columbia pebblesnail (Fluminicola columbiana), which is both a state and federal candidate species. Specimens of the shortface lanx were observed in the vicinity of N Springs (100-NR-1 Operable Unit); they likely occur throughout this area.

  9. Aquatic studies at the 100-HR-3 and 100-NR-1 operable units

    Energy Technology Data Exchange (ETDEWEB)

    Cushing, C.E.

    1993-04-01

    Pacific Northwest Laboratory initiated a program to characterize selected aquatic biological populations to determine (1) existing levels of inorganic chemical and radionuclide contamination, and (2) the populations' suitability as indicators of chemical releases during cleanup activities at the US Department of Energy's Hanford Site. Following work plans for the ground-water operable units, lower trophic levels in the aquatic habitat (periphyton and caddisfly larvae) were evaluated for contaminants at the 100-HR-3 Operable Unit and 100-NR-1 Operable Unit. The results were evaluated to determine the need for further sampling. If the results showed no significant contamination compared to upriver levels, sampling would be discontinued. The periphyton community appears to be suitable for determining contamination levels. Baseline concentrations for stable chromium were established and will be useful for comparing samples collected when contaminant release is expected. Concentrations of [sup 60]Co, [sup 90]Sr, and [sup 137]Cs in periphyton were essentially below detectable limits, which will also make this community useful in detecting potential releases of radionuclides during cleanup activities. Levels for both stable chromium and radionuclides were essentially below detection limits for caddisfly larvae. Thus, these organisms may be used to monitor suspected contaminant releases from cleanup activities; if concentrations exceed detection limits, they may be related to these activities. Two candidate threatened and endangered species of molluscs occur in the Hanford Reach of the Columbia River. These are the shortface lanx (Fisherola nuttalli), which is a Washington State candidate species, and the Columbia pebblesnail (Fluminicola columbiana), which is both a state and federal candidate species. Specimens of the shortface lanx were observed in the vicinity of N Springs (100-NR-1 Operable Unit); they likely occur throughout this area.

  10. EXTENDED CES(A)RO OPERATORS ON THE BLOCH SPACE IN THE UNIT BALL OF Cn

    Institute of Scientific and Technical Information of China (English)

    胡璋剑

    2003-01-01

    The paper defines an extended Cesàro operator Tg with holomorphic symbolg in the unit ball B of Cn asWhere g(z)= ∑j=1∑n zj g/ zj is the radial derivative of g. In this paper, the author characterizes g for which Tg is bounded (or compact) on the Bloch spaceB and the little Blochspace B0.

  11. Contaminant Attenuation and Transport Characterization of 200-DV-1 Operable Unit Sediment Samples

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Szecsody, James E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Qafoku, Nikolla [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Strickland, Christopher E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Moran, James J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lee, Brady D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Snyder, Michelle M.V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lawter, Amanda R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Resch, Charles T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gartman, Brandy N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhong, Lirong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Nims, Megan K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Saunders, Danielle L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Benjamin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Horner, Jacob A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Leavy, Ian I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Baum, Steven R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Christiansen, Beren B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clayton, Ray E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McElroy, Erin M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Appriou, Delphine [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tyrrell, Kimberly J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Striluk, Miranda L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-15

    A laboratory study was conducted to quantify contaminant attenuation processes and associated contaminant transport parameters that are needed to evaluate transport of contaminants through the vadose zone to the groundwater. The laboratory study information, in conjunction with transport analyses, can be used as input to evaluate the feasibility of Monitored Natural Attenuation and other remedies for the 200-DV-1 Operable Unit at the Hanford Site.

  12. Discrete Sampling Test Plan for the 200-BP-5 Operable Unit

    Energy Technology Data Exchange (ETDEWEB)

    Sweeney, Mark D.

    2010-02-04

    The Discrete Groundwater Sampling Project is conducted by the Pacific Northwest National Laboratory (PNNL) on behalf of CH2M HILL Plateau Remediation Company. The project is focused on delivering groundwater samples from proscribed horizons within select groundwater wells residing in the 200-BP-5 Operable Unit (200-BP-5 OU) on the Hanford Site. This document provides the scope, schedule, methodology, and other details of the PNNL discrete sampling effort.

  13. Data validation report for the 100-HR-3 Operable Unit, fifth round groundwater samples

    Energy Technology Data Exchange (ETDEWEB)

    Vukelich, S.E. [Kearney (A.T.), Inc., Chicago, IL (United States)

    1994-01-20

    The data from the chemical analysis of 68 samples from the 100-HR-3 Operable Unit Third Quarter 1993 Groundwater Sampling Investigation and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at the site. Sample analysis included inorganics and general chemical parameters. Fifty three samples were validated for radiochemical parameters.

  14. Baseline groundwater model update for p-area groundwater operable unit, NBN

    Energy Technology Data Exchange (ETDEWEB)

    Ross, J. [Savannah River Site (SRS), Aiken, SC (United States); Amidon, M. [Savannah River Site (SRS), Aiken, SC (United States)

    2015-09-01

    This report documents the development of a numerical groundwater flow and transport model of the hydrogeologic system of the P-Area Reactor Groundwater Operable Unit at the Savannah River Site (SRS) (Figure 1-1). The P-Area model provides a tool to aid in understanding the hydrologic and geochemical processes that control the development and migration of the current tritium, tetrachloroethene (PCE), and trichloroethene (TCE) plumes in this region.

  15. Initial closed operation of the CELSS Test Facility Engineering Development Unit

    Science.gov (United States)

    Kliss, M.; Blackwell, C.; Zografos, A.; Drews, M.; MacElroy, R.; McKenna, R.; Heyenga, A. G.

    2003-01-01

    As part of the NASA Advanced Life Support Flight Program, a Controlled Ecological Life Support System (CELSS) Test Facility Engineering Development Unit has been constructed and is undergoing initial operational testing at NASA Ames Research Center. The Engineering Development Unit (EDU) is a tightly closed, stringently controlled, ground-based testbed which provides a broad range of environmental conditions under which a variety of CELSS higher plant crops can be grown. Although the EDU was developed primarily to provide near-term engineering data and a realistic determination of the subsystem and system requirements necessary for the fabrication of a comparable flight unit, the EDU has also provided a means to evaluate plant crop productivity and physiology under controlled conditions. This paper describes the initial closed operational testing of the EDU, with emphasis on the hardware performance capabilities. Measured performance data during a 28-day closed operation period are compared with the specified functional requirements, and an example of inferring crop growth parameters from the test data is presented. Plans for future science and technology testing are also discussed. Published by Elsevier Science Ltd on behalf of COSPAR.

  16. Enhanced teaching and student learning through a simulator-based course in chemical unit operations design

    Science.gov (United States)

    Ghasem, Nayef

    2016-07-01

    This paper illustrates a teaching technique used in computer applications in chemical engineering employed for designing various unit operation processes, where the students learn about unit operations by designing them. The aim of the course is not to teach design, but rather to teach the fundamentals and the function of unit operation processes through simulators. A case study presenting the teaching method was evaluated using student surveys and faculty assessments, which were designed to measure the quality and effectiveness of the teaching method. The results of the questionnaire conclusively demonstrate that this method is an extremely efficient way of teaching a simulator-based course. In addition to that, this teaching method can easily be generalised and used in other courses. A student's final mark is determined by a combination of in-class assessments conducted based on cooperative and peer learning, progress tests and a final exam. Results revealed that peer learning can improve the overall quality of student learning and enhance student understanding.

  17. [Air conditioning units and warm air blankets in the operating room].

    Science.gov (United States)

    Kerwat, Klaus; Piechowiak, Karolin; Wulf, Hinnerk

    2013-01-01

    Nowadays almost all operating rooms are equipped with air conditioning (AC units). Their main purpose is climatization, like ventilation, moisturizing, cooling and also the warming of the room in large buildings. In operating rooms they have an additional function in the prevention of infections, especially the avoidance of postoperative wound infections. This is achieved by special filtration systems and by the creation of specific air currents. Since hypothermia is known to be an unambiguous factor for the development of postoperative wound infections, patients are often actively warmed intraoperatively using warm air blankets (forced-air warming units). In such cases it is frequently discussed whether such warm air blankets affect the performance of AC units by changing the air currents or whether, in contrast, have exactly the opposite effect. However, it has been demonstrated in numerous studies that warm air blankets do not have any relevant effect on the functioning of AC units. Also there are no indications that their use increases the rate of postoperative wound infections. By preventing the patient from experiencing hypothermia, the rate of postoperative wound infections can even be decreased thereby. © Georg Thieme Verlag Stuttgart · New York.

  18. Operation and results of the prototype KM3NeT detection unit

    Science.gov (United States)

    Biagi, Simone

    2016-07-01

    KM3NeT will be a km3-scale neutrino telescope in the Mediterranean Sea. The detector will consist of blocks of about one hundred detection units. Each detection unit will host 18 digital optical modules, connected along a 700 m-long vertical structure. Electro-optical cables allow for data transmission and power supply to the optical modules. The optical module comprises 31 photomultiplier tubes of 3'', instruments to monitor environmental variables and electronic boards to communicate onshore and operate the photomultipliers. A prototype detection unit has been deployed in May 2014 at the KM3NeT-It installation site 80 km SE offshore of Capo Passero, Sicily. This prototype allowed to test the deployment procedures, the mechanics and the electronic of the apparatus, the data taking and analysis procedures. A general description of the detector and some results of the prototype are presented. The first detection unit of the KM3NeT neutrino telescope will be deployed and become operative by the end of 2015.

  19. Operation and results of the prototype KM3NeT detection unit

    Directory of Open Access Journals (Sweden)

    Biagi Simone

    2016-01-01

    Full Text Available KM3NeT will be a km3-scale neutrino telescope in the Mediterranean Sea. The detector will consist of blocks of about one hundred detection units. Each detection unit will host 18 digital optical modules, connected along a 700 m-long vertical structure. Electro-optical cables allow for data transmission and power supply to the optical modules. The optical module comprises 31 photomultiplier tubes of 3′′, instruments to monitor environmental variables and electronic boards to communicate onshore and operate the photomultipliers. A prototype detection unit has been deployed in May 2014 at the KM3NeT-It installation site 80 km SE offshore of Capo Passero, Sicily. This prototype allowed to test the deployment procedures, the mechanics and the electronic of the apparatus, the data taking and analysis procedures. A general description of the detector and some results of the prototype are presented. The first detection unit of the KM3NeT neutrino telescope will be deployed and become operative by the end of 2015.

  20. 40 CFR 60.1200 - What are the operating practice requirements for my municipal waste combustion unit?

    Science.gov (United States)

    2010-07-01

    ... requirements for my municipal waste combustion unit? 60.1200 Section 60.1200 Protection of Environment... SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which Construction is... Good Combustion Practices: Operating Requirements § 60.1200 What are the operating practice...

  1. Operational Evaluation of VEGGIE Food Production System in the Habitat Demonstration Unit

    Science.gov (United States)

    Stutte, Gary W.; Newsham, Gerard; Morrow, Robert M.; Wheeler, Raymond M.

    2011-01-01

    The 2010 Desert Research and Technology Studies (DRATS) of the VEGGIE Food Production System in the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) was the first operational evaluation of salad crop production technology in a NASA analog test. A systematic evaluation of rooting media and nutrient delivery systems were evaluated for three lettuce cultivars that have shown promise as candidates for a surface based food production system. The VEGGIE nutrient delivery system worked well, was able to be maintained by multiple operators with a minimum of training, and supported excellent lettuce growth for the duration of the test. A Hazard Analysis and Critical Control Point (HACCP) evaluation was performed using ProSan(tm) as sanitation agent prior to consumption was approved, and the crew was allowed to consume the lettuce grown using the VEGGIE light cap and gravity based nutrient delivery system at the completion of the 14-day DRAT field test. The DRAT field test validated the crew operations; Growth of all lettuce cultivars was excellent. The operational DRAT field testing in the HDU identified light quality issues related to morphology and pigment development that will need to be addressed through additional testing. Feedback from the crew, ground support personnel, and human factors leads was uniformly positive on the psychological value of having the crop production system in the excursion module. A number of areas have been identified for future work, to minimize the "footprint" of the Food Production system through creative use of unused wall and floor space in the unit.

  2. Operation Evaluation of the VEGGIE Food Production System in the Habitat Demonstration Unit

    Science.gov (United States)

    Stutte, Gary W.; Newsham, Gerard; Morrow, Robert M.; Wheeler, Raymond M.

    2011-01-01

    The 2010 Desert Research and Technology Studies (DRATS) of the VEGGIE Food Production System in the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) was the first operational evaluation of salad crop production technology in a NASA analog test. A systematic evaluation of rooting media and nutrient delivery systems were evaluated for three lettuce cultivars that have shown promise as candidates for a surface based food production system. The VEGGIE nutrient delivery system worked well, was able to be maintained by multiple operators with a minimum of training, and supported excellent lettuce growth for the duration of the test. A Hazard Analysis and Critical Control Point (HACCP) evaluation was performed using ProSantm as sanitation agent prior to consumption was approved, and the crew was allowed to consume the lettuce grown using the VEGGIE light cap and gravity based nutrient delivery system at the completion of the 14-day DRAT field test. The DRAT field test validated the crew operations; Growth of all lettuce cultivars was excellent. The operational DRAT field testing in the HDU identified light quality issues related to morphology and pigment development that will need to be addressed through additional testing. Feedback from the crew, ground support personnel, and human factors leads was uniformly positive on the psychological value of having the crop production system in the excursion module. A number of areas have been identified for future work, to minimize the "footprint" of the Food Production system through creative use of unused wall and floor space in the unit.

  3. Pilot-scale treatability test plan for the 200-BP-5 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-BP-5 Operable Unit. This treatability test plan has been prepared in response to an agreement between the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA), and the State of Washington Department of Ecology (Ecology), as documented in Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement, Ecology et al. 1989a) Change Control Form M-13-93-03 (Ecology et al. 1994) and a recent 200 NPL Agreement Change Control Form (Appendix A). The agreement also requires that, following completion of the activities described in this test plan, a 200-BP-5 Operable Unit Interim Remedial Measure (IRM) Proposed Plan be developed for use in preparing an Interim Action Record of Decision (ROD). The IRM Proposed Plan will be supported by the results of this treatability test plan, as well as by other 200-BP-5 Operable Unit activities (e.g., development of a qualitative risk assessment). Once issued, the Interim Action ROD will specify the interim action(s) for groundwater contamination at the 200-BP-5 Operable Unit. The treatability test approach is to conduct a pilot-scale pump and treat test for each of the two contaminant plumes associated with the 200-BP-5 Operable Unit. Primary contaminants of concern are {sup 99}Tc and {sup 60}Co for underwater affected by past discharges to the 216-BY Cribs, and {sup 90}Sr, {sup 239/240}Pu, and Cs for groundwater affected by past discharges to the 216-B-5 Reverse Well. The purpose of the pilot-scale treatability testing presented in this testplan is to provide the data basis for preparing an IRM Proposed Plan. To achieve this objective, treatability testing must: Assess the performance of groundwater pumping with respect to the ability to extract a significant amount of the primary contaminant mass present in the two contaminant plumes.

  4. International Space Station United States Orbital Segment Oxygen Generation System On-Orbit Operational Experience

    Science.gov (United States)

    Erickson, Robert J.; Howe, John, Jr.; Kulp, Galen W.; VanKeuren, Steven P.

    2008-01-01

    The International Space Station (ISS) United States Orbital Segment (USOS) Oxygen Generation System (OGS) was originally intended to be installed in ISS Node 3. The OGS rack delivery was accelerated, and it was launched to ISS in July of 2006 and installed in the US Laboratory Module. Various modification kits were installed to provide its interfaces, and the OGS was first activated in July of 2007 for 15 hours, In October of 2007 it was again activated for 76 hours with varied production rates and day/night cycling. Operational time in each instance was limited by the quantity of feedwater in a Payload Water Reservoir (PWR) bag. Feedwater will be provided by PWR bag until the USOS Water Recovery System (WRS) is delivered to SS in fall of 2008. This paper will discuss operating experience and characteristics of the OGS, as well as operational issues and their resolution.

  5. Spacetime Quanta? : Real Discrete Spectrum of a Quantum Spacetime Four-Volume Operator in Unimodular Loop Quantum Cosmology

    CERN Document Server

    Bunao, Joseph

    2016-01-01

    This study considers the operator $\\hat{T}$ corresponding to the classical spacetime four-volume $T$ of a finite patch of spacetime in the context of Unimodular Loop Quantum Cosmology for the homogeneous and isotropic model with flat spatial sections and without matter sources. Since $T$ is canonically conjugate to the cosmological "constant" $\\Lambda$, the operator $\\hat{T}$ is constructed by solving its canonical commutation relation with $\\hat{\\Lambda}$ - the operator corresponding to $\\Lambda$. %This is done by expanding $\\hat{T}$ in terms of Bender-Dunne-like basis operators $\\hat{T}_{m,n}$ and solving for the expansion coefficients. This conjugacy, along with the action of $\\hat{T}$ on definite volume states reducing to $T$, allows us to interpret that $\\hat{T}$ is indeed a quantum spacetime four-volume operator. The eigenstates $\\Phi_{\\tau}$ are calculated and, considering $\\tau\\in\\mathbb{R}$, we find that the $\\Phi_{\\tau}$'s are normalizable suggesting that the real line $\\mathbb{R}$ is in the discret...

  6. Operating a High Volume Plankton Sampler from a Deep Water Autonomous Underwater Vehicle

    Science.gov (United States)

    Kaiser, C. L.; Billings, A.; Young, C.; Hiebert, L.; Van Dover, C. L.

    2016-02-01

    During the summer of 2015, a high volume plankton sampler was placed on the Autonomous Underwater Vehicle (AUV) Sentry as part of a cruise to investigate methane seeps. The sampler was successful in collecting over 800 larvae and 130 morphotypes. Most samples were split 2:1 or 4:1, so the total collection was substantially higher. The Sentry Precision Impeller Driven Sampler (SyPRID Sampler) was designed to mount as a "backpack" for the AUV Sentry. Sentry is able to fly the sampler at precision altitude as close as 150 cm from the seafloor and in precision patterns or locations for durations of 18 hours or more. Acoustic telemetry is used to monitor both Sentry and the samplers and to tune flight profiles or sampler operation in real time. Two independent samples can be collected per dive, allowing for comparative studies. The sampler is designed based on lessons learned from traditional tow-net systems and utilizes standard mesh net - in this case 150 micron. The sampler is impeller driven and Sentry moves at approximately 0.25m/s, resulting in little or no bow wave while maintaining an estimated flow rate of between 600 and 1000 m3/h per side. The sampler funnels plankton to a "cod end", where restriction and expansion is used to substantially reduce fluid pressure and velocity, thereby preserving the larvae in excellent condition. Valves are used to prevent contamination when not actively sampling. Substantial co-registered data is collected during the sampling including, CTD, optical backscatter, dissolved Oxygen, redox potential, and magnetics. When sampling more than 5m above bottom, multibeam sonar data can be collected. Future work will include simultaneous photography of the bottom for low-altitude sampling missions, real-time flow rate measurement, and simultaneous collection of ADCP water column data. Future work will also likely include use in the water column. The sampler is available for use on Sentry through UNOLS.

  7. Renewable Electricity Futures Study. Volume 4: Bulk Electric Power Systems. Operations and Transmission Planning

    Energy Technology Data Exchange (ETDEWEB)

    Milligan, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ela, Erik [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hein, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Schneider, Thomas [National Renewable Energy Lab. (NREL), Golden, CO (United States); Brinkman, Gregory [National Renewable Energy Lab. (NREL), Golden, CO (United States); Denholm, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-06-15

    The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%–90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT). Learn more at the RE Futures website. http://www.nrel.gov/analysis/re_futures/

  8. Renewable Electricity Futures Study. Volume 4: Bulk Electric Power Systems: Operations and Transmission Planning

    Energy Technology Data Exchange (ETDEWEB)

    Milligan, M.; Ela, E.; Hein, J.; Schneider, T.; Brinkman, G.; Denholm, P.

    2012-06-01

    The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%-90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT).

  9. Offpost Operable Unit Endangerment Assessment/Feasibility Study. Volume 1. Introduction

    Science.gov (United States)

    1992-11-24

    merits of remedial alternativos . Although there are inherent uncertainties in the groundwater model, this is a tool being used by the FS and predicted...J-intrc 0306111092 1-26 MIA1 1104 WEL 0CO. BOULDER CO. 25 85 LAOe JEFFERSON CO.7 A~ ROCK I MOUNTI ADAMS CO. DENVER CO. - -- ARAPAHOE CO. 17

  10. Remedial Investigation/Feasibility Study, Operable Unit 5, Elmendorf AFB, Anchorage, Alaska. Volume 1. Text

    Science.gov (United States)

    1994-03-04

    x1IV 1.67 x101 31655 014 0 WAS. IAmmdo 2.6-6.4 4.64 x100 US x 10’ 11.4 014 0 Roo. abib 50.3-96.7 7.19 x1If 7.54 x1IV 214.3 014 0 Root cadmim i 1.5-l...0.51 0.70 No ɘ.0005 ɘ.0005 • Cadmim 1.3 0.68 - 1.1 2.53 No ɘ.0012 ɘ.0012 Calcium 6,S20 5,090 - 5,610 8,490 No 3.7727 7.1394 Chromium 25.5 9.8. 12.0...L.auumpewmae Cadmim 11.3-27.5 4.2-6.5 Caper72-195 13-41 __________ ________ _ Lead 290 8 psmm;Cdim2.3 1.1 Copper 750 41 _________ _________ Liad 420 31

  11. History of Operations Research in the United States Army, Volume 1: 1942-1962

    Science.gov (United States)

    2006-11-08

    of Medical Corps offi cers, went to Fort Knox, Ken - tucky, in early 1942 to conduct studies on the performance of armored crewmen.365 OR in the...nicknamed “Cocky Kens ” after Dr. Kenneth Yudowitch, a member of the ORO team that did the initial analysis (see Visco, “Th e ORO,” p. 32). 142Smith...Johnson to Eisenhower, 1960, pp. 1–2. 421Jaff e, Quantitative Analysis, pp. 10–11. 422Dickson, Th ink Tanks, p. 150. 423Ltr, Wilber M. Brucker (secretary

  12. Accomplishing Shipyard Work for the United States Navy: Institutions, Systems and Operations. Volume I. Basic Report

    Science.gov (United States)

    1975-08-01

    8217Standard Metropolitan Statistical Areas (SI4SAs) are 269 geographical areas making up the fifty states and Puerto Rico. These areas are defined by the U.S...8217 * (2) Development of revised basing policies to provide I~o ovrhals f telv mothsduration or longer, the Navy has a policy of teprrlycagn tesi ’ home

  13. United States Air Force F-35A Operational Basing Environmental Impact Statement. Volume 2, Appendices

    Science.gov (United States)

    2013-09-01

    dishes, plaques, and bric -a-brac. Window panes may also vibrate noticeably when exposed to high levels of airborne noise, causing homeowners to fear...in stucco extended. Bric -a-brac Those carefully balanced or on edges can fall; fine glass, such as large goblets, can fall and break. Other Dust...water leakage. Bric -a-brac Some nominally secure items can fall; e.g., large pictures, especially if fixed to party walls. Source: Haber and Nakaki

  14. Trends in lumber processing in the western United States. Part I: board foot Scribner volume per cubic foot of timber

    Science.gov (United States)

    Charles E. Keegan; Todd A. Morgan; Keith A. Blatner; Jean M. Daniels

    2010-01-01

    This article describes trends in board foot Scribner volume per cubic foot of timber for logs processed by sawmills in the western United States. Board foot to cubic foot (BF/CF) ratios for the period from 2000 through 2006 ranged from 3.70 in Montana to 5.71 in the Four Corners Region (Arizona, Colorado, New Mexico, and Utah). Sawmills in the Four Corners Region,...

  15. Complications as indicators of quality assurance after 401 consecutive colorectal cancer resections: the importance of surgeon volume in developing colorectal cancer units in India

    Directory of Open Access Journals (Sweden)

    Shetty Guruprasad S

    2012-01-01

    Full Text Available Abstract Background The low incidence of colorectal cancer in India, coupled with absence of specialized units, contribute to lack of relevant data arising from the subcontinent. We evaluated the data of the senior author to better define the requirements that would enable development of specialized units in a country where colorectal cancer burden is increasing. Methods We retrospectively analyzed data of 401 consecutive colorectal resections from a prospective database of the senior author. In addition to patient demographics and types of resections, perioperative data like intraoperative blood loss, duration of surgery, complications, re-operation rates and hospital stay were recorded and analyzed. Results The median age was 52 years (10-86 years. 279 were males and 122 were females. The average duration of surgery was 220.32 minutes (range 50 - 480 min. The overall complication rate was 12.2% (49/401 with a 1.2% (5/401 mortality rate. The patients having complications had an increase in their median hospital stay (from 10.5 days to 23.4 days and the re-operation rate in them was 51%. The major complications were anastomotic leaks (2.5% and stoma related complications (2.7%. Conclusions This largest ever series from India compares favorably with global standards. In a nation where colorectal cancer is on the rise, it is imperative that high volume centers develop specialized units to train future specialist colorectal surgeons. This would ensure improved quality assurance and delivery of health care even to outreach, low volume centers.

  16. Discrete phase model representation of particulate matter (PM) for simulating PM separation by hydrodynamic unit operations.

    Science.gov (United States)

    Dickenson, Joshua A; Sansalone, John J

    2009-11-01

    Modeling the separation of dilute particulate matter (PM) has been a topic of interest since the introduction of unit operations for clarification of rainfall-runoff. One consistent yet controversial issue is the representation of PM and PM separation mechanisms for treatment. While Newton's Law and surface overflow rate were utilized, many historical models represented PM as a lumped gravimetric index largely out of economy and lack of particle analysis methods. As a result such models did not provide information about particle fate in or through a unit operation. In this study, PM discrete phase modeling (DPM) and computational fluid dynamics (CFD) are applied to model PM fate as a function of particle size and flow rate in two common types of hydrodynamic separator (HS) units. The study examines the discretization requirements (as a discretization number, DN) and errors for particle size distributions (PSDs) that range from the common heterodisperse to a monodisperse PSD. PSDs are categorized based on granulometric indices. Results focus on ensuring modeling accuracy while examining the role of size dispersivity and overall PM fineness on DN requirements. The fate of common heterodisperse PSDs is accurately predicted for a DN of 16, whereas a single particle size index, commonly the d(50m), is limited to monodisperse PSDs in order to achieve similar accuracy.

  17. Transition report, United States Department of Energy: A report to the President-Elect. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1988-11-01

    This report is a description of the Department of Energy organization and projects. The topics of the report include: (1) DOE organization and overview; (2) Headquarters Offices: Congressional, Intergovernmental and Public Affairs; Conservation and Renewable Energy; Contract Appeals; Defense Programs; Economic Regulatory Administration; Energy Information Administration; Energy Research; Environment, Safety and Health; Fossil Energy; General Counsel; Hearings and Appeals; Inspector General; International Affairs and Energy Emergencies; Management and Administration; Minority Economic Impact; New Production Reactors; Nuclear Energy; Policy, Planning and Analysis; Radioactive Waste Management; (3) Operations Offices: Albuquerque Operations Office; Chicago Operations Office; Idaho Operations Office; Nevada Operations Office; Oak Ridge Operations Office; Richland Operations Office; San Francisco Operations Office; Savannah River Operations Office; Laboratories; and (4) Power Administrations: Bonneville Power Administration; Western Area Power Administration.

  18. Spacetime quanta?: the discrete spectrum of a quantum spacetime four-volume operator in unimodular loop quantum cosmology

    Science.gov (United States)

    Bunao, J.

    2017-02-01

    This study considers the operator \\hat{T} corresponding to the classical spacetime four-volume \\tilde{T} (on-shell) of a finite patch of spacetime in the context of unimodular loop quantum cosmology for the homogeneous and isotropic model with flat spatial sections and without matter sources. Since the spacetime four-volume is canonically conjugate to the cosmological ‘constant’, the operator \\hat{T} is constructed by solving its canonical commutation relation with {\\hat Λ } —the operator corresponding to the classical cosmological constant on-shell {\\tilde Λ } . This conjugacy, along with the action of \\hat{T} on definite volume states reducing to \\tilde{T} , allows us to interpret that \\hat{T} is indeed a quantum spacetime four-volume operator. The discrete spectrum of \\hat{T} is calculated by considering the set of all τ’s where the eigenvalue equation has a solution {{ Φ }τ} in the domain of \\hat{T} . It turns out that, upon assigning the maximal domain D≤ft(\\hat{T}\\right) to \\hat{T} , we have {{ Φ }τ}\\in D≤ft(\\hat{T}\\right) for all τ \\in {C} so that the spectrum of \\hat{T} is purely discrete and is the entire complex plane. A family of operators {{\\hat{T}}≤ft({{b0},{φ0}\\right)}} was also considered as possible self-adjoint versions of \\hat{T} . They represent the restrictions of \\hat{T} on their respective domains D≤ft({{\\hat{T}}≤ft({{b0},{φ0}\\right)}}\\right) which are just the maximal domain with additional quasi-periodic conditions. Their possible self-adjointness is motivated by their discrete spectra only containing real and discrete numbers {τm} for m=0,+/- 1,+/- 2,... .

  19. Survey of fish impingement at power plants in the United States. Volume III. Estuaries and coastal waters

    Energy Technology Data Exchange (ETDEWEB)

    Stupka, Richard C.; Sharma, Rajendra K.

    1977-03-01

    Impingement of fish at cooling-water intakes of 32 power plants, located on estuaries and coastal waters has been surveyed and data are presented. Descriptions of site, plant, and intake design and operation are provided. Reports in this volume summarize impingement data for individual plants in tabular and histogram formats. Information was available from differing sources such as the utilities themselves, public documents, regulatory agencies, and others. Thus, the extent of detail in the reports varies greatly from plant to plant. Histogram preparation involved an extrapolation procedure that has inadequacies. The reader is cautioned in the use of information presented in this volume to determine intake-design acceptability or intensity of impacts on ecosystems. No conclusions are presented herein; data comparisons are made in Volume IV.

  20. The Applied Meteorology Unit: Nineteen Years Successfully Transitioning Research into Operations for America's Space Program

    Science.gov (United States)

    Madura, John T.; Bauman, William H.; Merceret, Francis J.; Roeder, William P.; Brody, Frank C.; Hagemeyer, Bartlett C.

    2010-01-01

    The Applied Meteorology Unit (AMU) provides technology transition and technique development to improve operational weather support to the Space Shuttle and the entire American space program. The AMU is funded and managed by NASA and operated by a contractor that provides five meteorologists with a diverse mix of advanced degrees, operational experience, and associated skills including data processing, statistics, and the development of graphical user interfaces. The AMU's primary customers are the U.S. Air Force 45th Weather Squadron at Patrick Air Force Base, the National Weather Service Spaceflight Meteorology Group at NASA Johnson Space Center, and the National Weather Service Melbourne FL Forecast Office. The AMU has transitioned research into operations for nineteen years and worked on a wide range of topics, including new forecasting techniques for lightning probability, synoptic peak winds,.convective winds, and summer severe weather; satellite tools to predict anvil cloud trajectories and evaluate camera line of sight for Space Shuttle launch; optimized radar scan strategies; evaluated and implemented local numerical models; evaluated weather sensors; and many more. The AMU has completed 113 projects with 5 more scheduled to be completed by the end of 2010. During this rich history, the AMU and its customers have learned many lessons on how to effectively transition research into operations. Some of these lessons learned include collocating with the operational customer and periodically visiting geographically separated customers, operator submitted projects, consensus tasking process, use of operator primary advocates for each project, customer AMU liaisons with experience in both operations and research, flexibility in adapting the project plan based on lessons learned during the project, and incorporating training and other transition assistance into the project plans. Operator involvement has been critical to the AMU's remarkable success and many awards

  1. Superfund record of decision (EPA Region 9): McClellan Air Force Base, Basewide Groundwater Operable Unit, Sacramento, CA, May 11, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Interim Record of Decision (ROD) presents the interim remedial action for the Groundwater Operable Unit (Groundwater OU) at the McClellan Air Force Base (McClellan AFB) Superfund site in Sacramento, California. The Groundwater OU addresses all of the VOC-contaminated groundwater at McClellan AFB. The Groundwater OU remedy is designed to prevent the spread of contamination that is already in the groundwater by containing groundwater with concentrations greater than maximum contaminant levels (MCLs). The remedy is also designed to remove to the maximum extent practicable the mass of contamination that lies in that volume of the groundwater.

  2. 78 FR 5167 - BE-9: Quarterly Survey of Foreign Airline Operators' Revenues and Expenses in the United States

    Science.gov (United States)

    2013-01-24

    ... Bureau of Economic Analysis XRIN 0691-XC003 BE-9: Quarterly Survey of Foreign Airline Operators' Revenues... Foreign Airline Operators' Revenues and Expenses in the United States (BE-9). This mandatory survey is..., agents, or other representatives of foreign airline operators that transport passengers or freight and...

  3. Selection of Forklift Unit for Warehouse Operation by Applying Multi-Criteria Analysis

    Directory of Open Access Journals (Sweden)

    Predrag Atanasković

    2013-07-01

    Full Text Available This paper presents research related to the choice of the criteria that can be used to perform an optimal selection of the forklift unit for warehouse operation. The analysis has been done with the aim of exploring the requirements and defining relevant criteria that are important when investment decision is made for forklift procurement, and based on the conducted research by applying multi-criteria analysis, to determine the appropriate parameters and their relative weights that form the input data and database for selection of the optimal handling unit. This paper presents an example of choosing the optimal forklift based on the selected criteria for the purpose of making the relevant investment decision.

  4. Cooling unit for a superconducting power cable. Two years successful operation

    Energy Technology Data Exchange (ETDEWEB)

    Herzog, Friedhelm [Messer Group GmbH, Krefeld (Germany); Kutz, Thomas [Messer Industriegase GmbH, Bad Soden (Germany); Stemmle, Mark [Nexans Deutschland GmbH, Hannover (Germany); Kugel, Torsten [Westnetz GmbH, Essen (Germany)

    2016-07-01

    High temperature super conductors (HTS) can efficiently be cooled with liquid nitrogen down to a temperature of 64 K (-209 C). Lower temperatures are not practical, because nitrogen becomes solid at 63 K (-210 C). To achieve this temperature level the coolant has to be vaporized below atmospheric pressure. Messer has developed a cooling unit with an adequate vacuum subcooler, a liquid nitrogen circulation system, and a storage vessel for cooling an HTS power cable. The cooling unit was delivered in 2013 for the German AmpaCity project of RWE Deutschland AG, Nexans and Karlsruhe Institute of Technology. Within this project RWE and Nexans installed the worldwide longest superconducting power cable in the city of Essen, Germany. The cable is in operation since March 10th, 2014.

  5. Cooling unit for the AmpaCity project - One year successful operation

    Science.gov (United States)

    Herzog, Friedhelm; Kutz, Thomas; Stemmle, Mark; Kugel, Torsten

    2016-12-01

    High temperature super conductors (HTS) can efficiently be cooled with liquid nitrogen down to a temperature of 64 K (-209 °C). Lower temperatures are not practical, because at 63 K (-210 °C) nitrogen becomes solid. To achieve this temperature level the coolant has to be vaporized below atmospheric pressure. Messer has developed a cooling unit with an adequate vacuum subcooler, a liquid nitrogen circulation system, and a storage vessel for cooling an HTS-power cable. Liquid nitrogen is circulated through the superconducting cable to take out the heat, and afterward it is pumped through the subcooler to be recooled. In the circulation system liquid nitrogen is used as a dielectric fluid and as a heat transfer medium. It stays always liquid (subcooled) and does not vaporize. On the secondary side of the subcooler liquid nitrogen from the storage vessel is used as refrigerant. It is vaporized under a pressure of 150 mbar to achieve the desired low temperatures. The cooling unit was delivered in 2013 for the German AmpaCity project of RWE Deutschland AG, Nexans and Karlsruhe Institute of Technology. Within this project RWE and Nexans installed the worldwide longest superconducting power cable in the city of Essen, Germany. The cooling unit cools a 10 kV concentric HTS cable (40 MV A) with a length of 1000 m. The cable is in operation since March 10th, 2014. After more than one year of practical operation many important figures from cable and cooling unit are available. These figures are discussed and a total energy balance is shown to compare liquid nitrogen cooling with alternative mechanical cooling systems.

  6. Operable Unit 3: Proposed Plan/Environmental Assessment for interim remedial action

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-01

    This document presents a Proposed Plan and an Environmental Assessment for an interim remedial action to be undertaken by the US Department of Energy (DOE) within Operable Unit 3 (OU3) at the Fernald Environmental Management Project (FEMP). This proposed plan provides site background information, describes the remedial alternatives being considered, presents a comparative evaluation of the alternatives and a rationnale for the identification of DOE`s preferred alternative, evaluates the potential environmental and public health effects associated with the alternatives, and outlines the public`s role in helping DOE and the EPA to make the final decision on a remedy.

  7. Quality and productivity drive innovation and improvement at United Technologies Aerospace Operations, Inc.

    Science.gov (United States)

    Jamar, L. G.

    1986-01-01

    Quality and innovation are the hallmarks of the national space program. In programs that preceded the Shuttle Program the emphasis was on meeting the risks and technical challenges of space with safety, quality, reliability, and success. At United Technologies Aerospace Operations, Inc. (UTAO), the battle has developed along four primary fronts. These fronts include programs to motivate and reward people, development and construction of optimized processes and facilities, implementation of specifically tailored management systems, and the application of appropriate measurement and control systems. Each of these initiatives is described. However, to put this quality and productivity program in perspective, UTAO and its role in the Shuttle Program are described first.

  8. Best management practices plan for the Lower East Fork Poplar Creek Operable Unit, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    This plan was prepared in support of the Phase II Remedial Design Report (DOE/OR/01-1449&D1) and in accordance with requirements under CERCLA to present the plan for best management practices to be followed during the remediation. This document provides the Environmental Restoration Program with information about spill prevention and control, water quality monitoring, good housekeeping practices, sediment and erosion control measures, and inspections and environmental compliance practices to be used during Phase II of the remediation project for the Lower East Fork Poplar Creek Operable Unit.

  9. Remedial investigation/feasibility study work plan for the 100-BC-2 operable unit, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    This work plan and attached supporting project plans establish the operable unit setting and the objectives, procedures, tasks, and schedule for conducting the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) remedial investigation/feasibility study (RI/FS) for the 100-BC-2 operable unit in the 100 Area of the Hanford Site. The 100 Area is one of four areas at the Hanford Site that are on the US Environmental Protection Agency`s (EPA) National Priorities List under CERCLA. The 100-BC-2 operable unit is one of two source operable units in the 100-B/C Area (Figure ES-1). Source operable units are those that contain facilities and unplanned release sites that are potential sources of hazardous substance contamination. The 100-BC-2 source operable unit contains waste sites that were formerly in the 100-BC-2, 100-BC-3, and 100-BC-4 operable units. Because of their size and geographic location, the waste sites from these two operable units were added to 100-BC-2. This allows for a more efficient and effective investigation of the remaining 100-B/C Reactor area waste sites. The investigative approach to waste sites associated with the 100-BC-2 operable unit are listed in Table ES-1. The waste sites fall into three general categories: high priority liquid waste disposal sites, low priority liquid waste disposal sites, and solid waste burial grounds. Several sites have been identified as candidates for conducting an IRM. Two sites have been identified as warranting additional limited field sampling. The two sites are the 116-C-2A pluto crib, and the 116-C-2C sand filter.

  10. Viability Assessment of a Repository at Yucca Mountain. Volume 5: Costs to Construct and Operate the Repository

    Energy Technology Data Exchange (ETDEWEB)

    None

    1998-12-01

    This volume presents a management summary of the cost estimate to complete the design, and to license, construct, operate, monitor, close, and decommission a Monitored Geologic Repository at Yucca Mountain in Nevada. This volume summarizes the scope, estimating methodologies, and assumptions used in development of the Monitored Geologic Repository-VA cost estimate. It identifies the key features necessary to understand the summary costs presented herein. This cost summary derives from a larger body of documented cost analysis. Volume 5 is organized to reflect this structured approach to cost estimation and contains the following sections: Section 1, Cost Elements. This section briefly defines the components of each major repository cost element. Section 2, Project Phases. This section presents the definition, as used in the estimate, of five project phases (Licensing, Pre-emplacement Construction, Emplacement Operations, Monitoring, and Closure and Decommissioning) and the schedule dates for each phase. It also contains major milestone dates and a bar chart schedule. Section 3, Major Assumptions. This section identifies key high-level assumptions for the cost estimate basis. Additional detailed assumptions are included in the appendices. Section 4, Integrated Cost Summary. This section presents a high-level roll-up of the VA costs resulting from the estimating work. The tables and figures contained in this section were compiled from the more detailed cost estimates in the appendices. Section 5, References. This section identifies the references that support this cost volume. Appendices. For each major repository cost element, Appendices B-F [B, C, D, E, F] presents additional information on the scope of cost elements, identifies methodologies used to develop the cost estimates, lists underlying cost assumptions, and tabulates summary results. Appendix A contains a glossary to assist the reader in understanding the terminology in Volume 5. Appendix G presents costs

  11. Logistics measurement and performance for United States-Mexican operations under NAFTA

    Energy Technology Data Exchange (ETDEWEB)

    Fawcett, S.E. [Michigan State Univ., East Lansing, MI (United States); Smith, S.R. [Brigham Young Univ., Laie, HI (United States)

    1995-12-01

    An empirical study utilizing a survey methodology was undertaken to explore the issues surrounding logistics performance under the recently enacted North American Free Trade Agreement (NAFTA). The study surveyed 524 senior level managers directly responsible for their strategic business units` operations involving Mexican production sharing. The study focused on what role Mexican production facilities take in the production process, relative technology level, planning activities, final destination of products, and what level of logistics performance was required to successfully operate. Some of the findings suggest a need to reevaluate current strategies to incorporate logistics support systems. Many benefits of true integration may have been overlooked since logistics was given a secondary position when strategies were formulated. Excessive tranportation and distribution costs may be lowered if logistics is given a higher emphasis in corporate decision making.

  12. Maintenance and operation of a hydroelectric unit of energy in a power system using virtual reality

    Energy Technology Data Exchange (ETDEWEB)

    de Sousa, Marcos Paulo Alves [Federal University of Para, Faculty of Engineering Computing, Augusto Correa Street, No. 1, Belem, Para (Brazil); Emilio Goeldi Museum, Service Data Processing Department, Perimetral Avenue No. 1901, Belem, Para (Brazil); Filho, Manoel Ribeiro; Nunes, Marcus Vinicius Alves; Lopes, Andrey da Costa [Federal University of Para, Faculty of Engineering Computing, Augusto Correa Street, No. 1, Belem, Para (Brazil)

    2010-07-15

    This paper presents a new approach to training for hydroelectric unit of energy (HUE) by using virtual reality Non-immersive techniques. The software offers two modules of training: maintenance and operation. The first module, maintenance, uses the learning approach based on practice and offers different training levels, divided into three modes: automatic, guided, and exploratory, in which these modes are accessed according to the acquired degree of knowledge by the trainee in relation to maintenance procedures. The second module, allows the trainee to visualize the operation of HUE during a certain event as the electromechanical dynamics of the turbine-generator assemblage in the virtual world by the visualization of several requisite conditions before the startup-shutdown procedure of HUE. (author)

  13. Agricultural Mechanics Unit for Plant Science Core Curriculum. Volume 15, Number 4. Instructor's Guide.

    Science.gov (United States)

    Linhardt, Richard E.; Hunter, Bill

    This instructor's guide is intended for use in teaching the agricultural mechanics unit of a plant science core curriculum. Covered in the individual units of the guide are the following topics: arc welding (following safety procedures, controlling distortion, selecting and caring for electrodes, identifying the material to be welded, and welding…

  14. Hypophosphatemia on the intensive care unit: individualized phosphate replacement based on serum levels and distribution volume.

    NARCIS (Netherlands)

    Bech, A.; Blans, M.; Raaijmakers, M.; Mulkens, C.; Telting, D.; Boer, H. de

    2013-01-01

    BACKGROUND: Hypophosphatemia occurs in about 25% of patients admitted to the intensive care unit. To date, a safe and validated phosphate replacement protocol is not available. OBJECTIVE: To evaluate an individualized phosphate replacement regimen. DESIGN: Fifty consecutive intensive care unit patie

  15. Overview of the Habitat Demonstration Unit Power System Integration and Operation at Desert RATS 2010

    Science.gov (United States)

    Colozza, Anthony J.; George, Pat; Gambrell, Ronnie; Chapman, Chris

    2013-01-01

    A habitat demonstration unit (HDU) was constructed at NASA Johnson Space Center (JSC) and designed by a multicenter NASA team led out of NASA Kennedy Space Center (KSC). The HDU was subsequently utilized at the 2010 Desert Research and Technology Studies (RATS) program held at the Black Point Lava Flow in Arizona. This report describes the power system design, installation and operation for the HDU. The requirements for the power system were to provide 120 VAC, 28 VDC, and 120 VDC power to the various loads within the HDU. It also needed to be capable of providing power control and real-time operational data on the load's power consumption. The power system had to be capable of operating off of a 3 phase 480 VAC generator as well as 2 solar photovoltaic (PV) power systems. The system operated well during the 2 week Desert RATS campaign and met all of the main goals of the system. The power system is being further developed to meet the future needs of the HDU and options for this further development are discussed.

  16. Light weight portable operator control unit using an Android-enabled mobile phone

    Science.gov (United States)

    Fung, Nicholas

    2011-05-01

    There have been large gains in the field of robotics, both in hardware sophistication and technical capabilities. However, as more capable robots have been developed and introduced to battlefield environments, the problem of interfacing with human controllers has proven to be challenging. Particularly in the field of military applications, controller requirements can be stringent and can range from size and power consumption, to durability and cost. Traditional operator control units (OCUs) tend to resemble laptop personal computers (PCs), as these devices are mobile and have ample computing power. However, laptop PCs are bulky and have greater power requirements. To approach this problem, a light weight, inexpensive controller was created based on a mobile phone running the Android operating system. It was designed to control an iRobot Packbot through the Army Research Laboratory (ARL) in-house Agile Computing Infrastructure (ACI). The hardware capabilities of the mobile phone, such as Wi- Fi communications, touch screen interface, and the flexibility of the Android operating system, made it a compelling platform. The Android based OCU offers a more portable package and can be easily carried by a soldier along with normal gear requirements. In addition, the one hand operation of the Android OCU allows for the Soldier to keep an unoccupied hand for greater flexibility. To validate the Android OCU as a capable controller, experimental data was collected evaluating use of the controller and a traditional, tablet PC based OCU. Initial analysis suggests that the Android OCU performed positively in qualitative data collected from participants.

  17. Tracheotomy in Pediatric Patients: In Operating Room or Intensive Care Unit?

    Directory of Open Access Journals (Sweden)

    Umut Kaygusuz

    2014-08-01

    Full Text Available Introduction: The morbidity and mortality rates of tracheotomy are higher in the pediatric population because the incision is small and the trachea is more prone to surgical trauma. Tracheotomy procedure is mostly performed in operating room in most institutions. The aim of the study is to compare the outcomes of tracheotomy procedures between intensive care unit (ICU and operating room (OR in terms of pitfalls, complications and family preferences. Materials and Methods: In between June 2012 and July 2013, at a single institution, 39 patients were prospectively analyzed for age, gender, primary pathology, tracheotomy indications, location of operation, the duration of family consent, perioperative complications and presence of decanulation. Results: Male/female ratio was 20/19. Mean age was 49.9±52.5 (4-204 months. Tracheotomy procedure was performed in OR in 19 patients (45% and in ICU in 20 (54.5% patients. There was no statistically significant difference between groups in terms of complications (OR-48.7%, ICU-51.3%. The time of informed consent was significantly shorter in ICU patients. Conclusions: There is no significant difference in terms of safety for tracheotomy procedure in ICU or OR. Parents give approval to a bedside invasive procedure faster. The words ‘Surgery’ and ‘Operating room’ can easily confuse the parents, extend the duration for endolaryngeal intubation, and increase the cost and labour loss.

  18. Steering quantum-memory-assisted entropic uncertainty under unital and nonunital noises via filtering operations

    Science.gov (United States)

    Huang, Ai-Jun; Shi, Jia-Dong; Wang, Dong; Ye, Liu

    2017-02-01

    In this work, we investigate the dynamic features of the entropic uncertainty for two incompatible measurements under local unital and nonunital channels. Herein, we choose Pauli operators σ _x and σ _z as a pair of observables of interest measuring on particle A, and the uncertainty can be predicted when particle A is entangled with quantum memory B. We explore the dynamics of the uncertainty for the measurement under local unitary (phase-damping) and nonunitary (amplitude-damping) channels, respectively. Remarkably, we derive the entropic uncertainty relation under three different kinds of measurements of Pauli-observable pair under various realistic noisy environments; it has been found that the entropic uncertainty has the same tendency of its evolution during the AD and PD channel when we choose σ _x and σ _y measurement. Besides, we find out that the entropic uncertainty will have an optimal value if one chooses σ _x and σ _z as the measurement incompatibility, comparing with others. Furthermore, in order to reduce the entropic uncertainty in noisy environment, we propose an effective strategy to steer the amount by means of implementing a filtering operation on the particle under the two types of channels, respectively. It turns out that this operation can greatly reduce the entropic uncertainty by modulation of the operation strength. Thus, our investigations might offer an insight into the dynamics and steering of the entropic uncertainty in an open system.

  19. Analysis of airborne radiometric data. Volume 2. Description, listing, and operating instructions for the code DELPHI/MAZAS. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Sperling, M.; Shreve, D.C.

    1978-12-01

    The computer code DELPHI is an interactive English language command system for the analysis of airborne radiometric data. The code includes modules for data reduction, data simulation, time filtering, data adjustment and graphical presentation of the results. DELPHI is implemented in FORTRAN on a DEC-10 computer. This volume gives a brief set of operations instructions, samples of the output obtained from hard copies of the display on a Tektronix terminal and finally a listing of the code.

  20. Water Treatment Plant Operation. Volume I. A Field Study Training Program.

    Science.gov (United States)

    California State Univ., Sacramento. School of Engineering.

    The purpose of this water treatment field study training program is to: (1) develop new qualified water treatment plant operators; (2) expand the abilities of existing operators, permitting better service both to employers and public; and (3) prepare operators for civil service and certification examinations (examinations administered by…

  1. Water Treatment Plant Operation. Volume II. A Field Study Training Program.

    Science.gov (United States)

    California State Univ., Sacramento. School of Engineering.

    The purpose of this water treatment field study training program is to: (1) develop new qualified water treatment plant operators; (2) expand the abilities of existing operators, permitting better service both to employers and public; and (3) prepare operators for civil service and certification examinations (examinations administered by…

  2. Water Treatment Plant Operation Volume 2. A Field Study Training Program. Revised.

    Science.gov (United States)

    California State Univ., Sacramento. School of Engineering.

    The purpose of this water treatment field study training program is to: (1) develop new qualified water treatment plant operators; (2) expand the abilities of existing operators, permitting better service both to employers and public; and (3) prepare operators for civil service and certification examinations (examinations administered by…

  3. Operation of Wastewater Treatment Plants. Volume 1. A Field Study Training Program. Third Edition. Revised.

    Science.gov (United States)

    California State Univ., Sacramento. Dept. of Civil Engineering.

    The purpose of this wastewater treatment field study training program is to: (1) develop new qualified wastewater treatment plant operators; (2) expand the abilities of existing operators, permitting better service both to employers and public; and (3) prepare operators for civil service and certification examinations (examinations administered by…

  4. Evaluation of the Synthoil process. Volume III. Unit block flow diagrams for a 100,000 barrel/stream day facility

    Energy Technology Data Exchange (ETDEWEB)

    Salmon, R.; Edwards, M.S.; Ulrich, W.C.

    1977-06-01

    This volume consists of individual block flowsheets for the various units of the Synthoil facility, showing the overall flows into and out of each unit. Material balances for the following units are incomplete because these are proprietary processes and the information was not provided by the respective vendors: Unit 24-Claus Sulfur Plant; Unit 25-Oxygen Plant; Unit 27-Sulfur Plant (Redox Type); and Unit 28-Sour Water Stripper and Ammonia Recovery Plant. The process information in this form was specifically requested by ERDA/FE for inclusion in the final report.

  5. International and United States documents on oceans law and policy. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Moore, J.N. (ed.)

    1986-01-01

    Volume 2 of the five-volume series continues the major international documents of Volume 1 relating to ocean issues. It groups the documents under three major headings: Cooperative agreements for port regulation and development, Living resources, and Environmental protection. The Living resources section is further divided into Coastal fisheries, Anadromous species, Highly migratory species, and Marine Mammals. Subdivisions under the Environmental protection section are General principles, Regional protection, Vessel-source pollution, Ocean dumping, Land-based pollution, Civil liability and compensation, and Endangered species. The title page for each document includes full citations, although some documents have been edited. A separate abstract was prepared for each of the seven sections under Environmental protection.

  6. Evaluation of economic and technical efficiency of diesel engines operation on the basis of volume combustion rate

    Directory of Open Access Journals (Sweden)

    І. О. Берестовой

    2016-11-01

    Full Text Available The article deals with a new approach to evaluation of complex efficiency of diesel engines. Traditionally, cylinder’s capacity, rotation frequency, average efficient pressure inside cylinder, piston’s stroke, average piston’s velocity, fuel specific consumption and other indices are used as generalizing criteria, characterizing diesel engine’s efficiency, but they do not reflect interrelation between engine’s complex efficiency and a set of economic, mass-dimensional, operational and ecological efficiency. The approach applied in the article makes it possible to reveal the existing and modify the existing methods of solving the problem of improving diesel engine’s efficiency with due regard to interrelation of the parameters, characterizing efficiency of their operation. Statistic analyses were carried out, on the basis of which an assumption regarding the existence of interrelation between specific fuel consumption and the analyzed engine’s parameters was made. Processing of statistical data for various analyzed functions of diesel engines helped offer a function, illustrating the link between volume combustion rate, piston’s area and nominal theoretical specific fuel consumption. Interrelation between volume combustion rate, nominal parameters of diesel operation and efficiency indices, obtained by processing statistical data of more than 500 models of diesels of different series was evaluated, the main feature of it being a mathematical trend. The analysis of the obtained function makes it possible to establish an interrelation between economic efficiency of a diesel, its main index being specific fuel consumption and volume combustion rate and design peculiarities

  7. Quantification of respiratory depression during pre-operative administration of midazolam using a non-invasive respiratory volume monitor

    Science.gov (United States)

    Gonzalez Castro, Luis N.; Mehta, Jaideep H.; Brayanov, Jordan B.; Mullen, Gary J.

    2017-01-01

    Background Pre-operative administration of benzodiazepines can cause hypoventilation—a decrease in minute ventilation (MV)—commonly referred to as “respiratory compromise or respiratory depression.” Respiratory depression can lead to hypercarbia and / or hypoxemia, and may heighten the risk of other respiratory complications. Current anesthesia practice often places patients at risk for respiratory complications even before surgery, as respiratory monitoring is generally postponed until the patient is in the operating room. In the present study we examined and quantified the onset of respiratory depression following the administration of a single dose of midazolam in pre-operative patients, using a non-invasive respiratory volume monitor that reports MV, tidal volume (TV), and respiratory rate (RR). Methods Impedance-based Respiratory Volume Monitor (RVM) data were collected and analyzed from 30 patients prior to undergoing orthopedic or general surgical procedures. All patients received 2.0 mg of midazolam intravenously at least 20 minutes prior to the induction of anesthesia and the effects of midazolam on the patient's respiratory function were analyzed. Results Within 15 minutes of midazolam administration, we noted a significant decrease in both MV (average decrease of 14.3% ± 5.9%, pbenzodiazepines affect primarily TV rather than RR. Such respiratory monitoring data provide the opportunity for individualizing dosing and adjustment of clinical interventions, especially important in elderly patients. With additional respiratory data, clinicians may be able to better identify and quantify respiratory depression, reduce adverse effects, and improve overall patient safety. PMID:28235069

  8. Joint Peru/United States report on Peru/United States cooperative energy assessment. Volume 3. Annexes 2-7

    Energy Technology Data Exchange (ETDEWEB)

    1979-08-01

    This report presents the results of a brief study of industral, mining, and agricultural sector energy demands in Peru. The study establishes current energy demands and sectoral activities, and projects future energy needs through the year 2000. With respect to energy demands, the subsectors covered are: mining and non-ferrous metals, iron and steel, cement, oil refining, petrochemicals, fertilizers, and agriculture (major crops). Total energy demands for these subsectors are developed for 1976, 1985, and 2000, assuming full-capacity operation for the majority of the plants. Potential options developed for reducing energy use in these sectors are: increased coal use, improved energy efficiency in the manufacturing sector, use of agricultural wastes as fuel, possible displacement of oil by hydroelectricity, use of geothermal energy, increased use of water materials for the cement and construction industries, and possible promotion of cogeneration systems (electricity/steam). (MCW)

  9. Do different populations of Aphanius dispar in Southern Iran form Operational Taxonomic Units (OUTs?

    Directory of Open Access Journals (Sweden)

    Azad Teimori

    2015-10-01

    Full Text Available Deciphering the exact fundamental relations of morphological differentiation among isolated populations of animal species is generally difficult. Usually changes in morphology are resulted from adaptation to different environmental conditions (ecoplasticity or represent an expression of genetic differences and/or gene pool pauperization, and in most instances, however, changes in morphology are the result of the interplay between environmental factors and genetic plasticity. In this study, the morphology and molecular phylogenies of common tooth-carp populations (Aphanius dispar were studied in three basins in Southern part of Iran to discuss an important aspect relate to the question whether morphologically differentiated populations of a single species function as Operational Taxonomic Units. All morphological analyses were revealed significant and strong morphological differentiation between the populations that corresponds well with their zoogeography and their molecular phylogeny in geographically isolated basins. Therefore, it can be concluded that when the interaction between gene flow among populations and natural selection is resulted owing to a long evolutionary history, then the observed morphological differences can be functioned as different Operational Taxonomic Units (OTUs in subspecies or even species levels. In addition, biological characteristics of the A. dispar, its high tolerance, geological and ecological conditions in Southern Iran are the main factors that increase chance of reproductive isolation and genetic diversity in this region.

  10. Explicit isospectral flows associated to the AKNS operator on the unit interval. II

    Science.gov (United States)

    Amour, Laurent

    2012-10-01

    Explicit flows associated to any tangent vector fields on any isospectral manifold for the AKNS operator acting in L2 × L2 on the unit interval are written down. The manifolds are of infinite dimension (and infinite codimension). The flows are called isospectral and also are Hamiltonian flows. It is proven that they may be explicitly expressed in terms of regularized determinants of infinite matrix-valued functions with entries depending only on the spectral data at the starting point of the flow. The tangent vector fields are decomposed as ∑ξkTk where ξ ∈ ℓ2 and the Tk ∈ L2 × L2 form a particular basis of the tangent vector spaces of the infinite dimensional manifold. The paper here is a continuation of Amour ["Explicit isospectral flows for the AKNS operator on the unit interval," Inverse Probl. 25, 095008 (2009)], 10.1088/0266-5611/25/9/095008 where, except for a finite number, all the components of the sequence ξ are zero in order to obtain an explicit expression for the isospectral flows. The regularized determinants induce counter-terms allowing for the consideration of finite quantities when the sequences ξ run all over ℓ2.

  11. Current Conditions Risk Assessment for the 300-FF-5 Groundwater Operable Unit

    Energy Technology Data Exchange (ETDEWEB)

    Miley, Terri B.; Bunn, Amoret L.; Napier, Bruce A.; Peterson, Robert E.; Becker, James M.

    2007-11-01

    This report updates a baseline risk assessment for the 300 Area prepared in 1994. The update includes consideration of changes in contaminants of interest and in the environment that have occurred during the period of interim remedial action, i.e., 1996 to the present, as well as the sub-regions, for which no initial risk assessments have been conducted. In 1996, a record of decision (ROD) stipulated interim remedial action for groundwater affected by releases from 300 Area sources, as follows: (a) continued monitoring of groundwater that is contaminated above health-based levels to ensure that concentrations continue to decrease, and (b) institutional controls to ensure that groundwater use is restricted to prevent unacceptable exposure to groundwater contamination. In 2000, the groundwater beneath the two outlying sub-regions was added to the operable unit. In 2001, the first 5-year review of the ROD found that the interim remedy and remedial action objectives were still appropriate, although the review called for additional characterization activities. This report includes a current conditions baseline ecological and human health risk assessment using maximum concentrations in the environmental media of the 300-FF-5 Operable Unit and downstream conditions at the City of Richland, Washington. The scope for this assessment includes only current measured environmental concentrations and current use scenarios. Future environmental concentrations and future land uses are not considered in this assessment.

  12. Phase I and II feasibility study report for the 300-FF-5 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    The purpose of this Phase I/II feasibility study is to assemble and screen a list of alternatives for remediation of the 300-FF-5 operable site on the Hanford Reservation. This screening is based on information gathered in the Phase I Remedial Investigation (RI) and on currently available information on remediation technologies. The alternatives remaining after screening provide a range of response actions for remediation. In addition, key data needs are identified for collection during a Phase II RI (if necessary). This Phase I/II FS represents a primary document as defined by the Tri-Party Agreement, but will be followed by a Phase III FS that will further develop the alternatives and provide a detailed evaluation of them. The following remedial action objectives were identified for the 300-FF-5 operable unit: Limit current human exposure to contaminated groundwater in the unit; Limit discharge of contaminated groundwater to the Columbia River; Reduce contaminant concentrations in groundwater below acceptable levels by the year 2018.

  13. The volumes and value of non-timber forest products harvested in the United States

    Science.gov (United States)

    James L. Chamberlain

    2015-01-01

    Non-timber forest products [NTFPs] originate from plants and fungi that are harvested from natural, manipulated or disturbed forests. NTFPs may include fungi, moss, lichen, herbs, vines, shrubs, or trees. People harvest the products for many reasons, including personal, recreational and spiritual uses, as well as commercial gain. The assessment of volumes and values is...

  14. An evaluation of known remaining oil resources in the United States: Appendix. Volume 10

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-11-01

    Volume ten contains the following appendices: overview of improved oil recovery methods which covers enhanced oil recovery methods and advanced secondary recovery methods; the benefits of improved oil recovery, selected data for the analyzed states; and list of TORIS fields and reservoirs.

  15. Interprofessional rhetoric and operational realities: an ethnographic study of rounds in four intensive care units.

    Science.gov (United States)

    Paradis, Elise; Leslie, Myles; Gropper, Michael A

    2016-10-01

    Morning interprofessional rounds (MIRs) are used in critical care medicine to improve team-based care and patient outcomes. Given existing evidence of conflict between and dissatisfaction among rounds participants, this study sought to better understand how the operational realities of care delivery in the intensive care unit (ICU) impact the success of MIRs. We conducted a year-long comparative ethnographic study of interprofessional collaboration and patient and family involvement in four ICUs in tertiary academic hospitals in two American cities. The study included 576 h of observation of team interactions, 47 shadowing sessions and 40 clinician interviews. In line with best practices in ethnographic research, data collection and analysis were done iteratively using the constant comparative method. Member check was conducted regularly throughout the project. MIRs were implemented on all units with the explicit goals of improving team-based and patient-centered care. Operational conditions on the units, despite interprofessional commitment and engagement, appeared to thwart ICU teams from achieving these goals. Specifically, time constraints, struggles over space, and conflicts between MIRs' educational and care-plan-development functions all prevented teams from achieving collaboration and patient-involvement. Moreover, physicians' de facto control of rounds often meant that they resembled medical rounds (their historical predecessors), and sidelined other providers' contributions. This study suggests that the MIRs model, as presently practiced, might not be well suited to the provision of team-based, patient-centered care. In the interest of interprofessional collaboration, of the optimization of clinicians' time, of high-quality medical education and of patient-centered care, further research on interprofessional rounds models is needed.

  16. Fukushima Daiichi Unit 1 Uncertainty Analysis-Exploration of Core Melt Progression Uncertain Parameters-Volume II.

    Energy Technology Data Exchange (ETDEWEB)

    Denman, Matthew R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brooks, Dusty Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-08-01

    Sandia National Laboratories (SNL) has conducted an uncertainty analysi s (UA) on the Fukushima Daiichi unit (1F1) accident progression wit h the MELCOR code. Volume I of the 1F1 UA discusses the physical modeling details and time history results of the UA. Volume II of the 1F1 UA discusses the statistical viewpoint. The model used was developed for a previous accident reconstruction investigation jointly sponsored by the US Department of Energy (DOE) and Nuclear Regulatory Commission (NRC). The goal of this work was to perform a focused evaluation of uncertainty in core damage progression behavior and its effect on key figures - of - merit (e.g., hydrogen production, fraction of intact fuel, vessel lower head failure) and in doing so assess the applicability of traditional sensitivity analysis techniques .

  17. Morbidity and Mortality Weekly Report. Volume 43, Number 53. Summary of Notifiable Diseases, United States, 1994.

    Science.gov (United States)

    2007-11-02

    VII Drug-resi stant Streptococcus pneumoniae In the United States, the prevalence of drug-resistant Streptococcus pneumoniae (DRSP) has increased...hospitals indicate the proportion of invasive disease (bacteremia and meningitis) caused by penicillin -resistant pneumococci ranges from 3% to 30% and shows...from noncritical care units, suggesting that vancomy- cin-resistant enterococci are spreading from their focus in ICUs. Pneumonia of unknown etiology

  18. Record of Decision for the Rocky Mountain Arsenal On-Post Operable Unit in southern Adams County, Commerce City, Colorado.

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This Record of Decision (ROD) presents the selected remedial action for the Rocky Mountain Arsenal (RMA) On-Post Operable Unit in southern Adams County (east of...

  19. A descriptive survey of management and operations at selected sports medicine centers in the United States.

    Science.gov (United States)

    Olsen, D

    1996-11-01

    No uniform guidelines for operations or accreditation standards for sports medicine center were available and, at the time of this study, little information on the management and operation of sports medicine centers was available in the literature. The purpose of the study was to determine the management structure and function of selected sports medicine centers in the United States. Questionnaires were mailed to 200 randomly selected centers throughout the United State from a directory of sports medicine centers published in Physician and Sportsmedicine (1992) to gather descriptive information on eight areas, including 1) general background, 2) staffing, 3) services, facilities, and equipment, 4) billing, collections, and revenue, 5) clientele, caseloads, and referrals, 6) ownership and financing, 7) school and club outreach contracts, and 8) marketing strategies and future trends. A total of 71 surveys (35.5%) were returned in the allotted time frame. Data were analyzed using ranges, means, medians, modes, and percentages. Results yielded several conclusions about sports medicine centers. Nearly all (93%) of the centers employed physical therapists; physical therapists were clinical directors at 70.2% of centers; orthopaedists were most often medical directors; rehabilitation was the most frequently offered service (93%); physical therapy produced the highest revenue; sports injuries accounted for a mean 34.5% of patients, who were mostly recreational or high school athletes between 13-60 years of age; primary shareholders were most often physical therapists or physicians; most were involved in outreach services for schools; marketing strategies primarily involved communication with referral sources; and managed care was identified most frequently as a trend affecting the future of sports medicine centers. Findings identified common aspects of sports medicine centers and may assist in establishing guidelines for operations or accreditation of sports medicine

  20. New source performance standards for industrial boilers. Volume 2. Review of industry operating practices

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, R.J.; Weisenberg, I.J.; Wilson, K.

    1980-09-01

    The applicability is evaluated of several possible versions of a revised New Source Performance Standards (NSPS) for industrial boilers to boilers that are operated according to typical industry practices. A survey of operating practices is presented, and it is concluded that an NSPS that includes too high a percent removal requirement for SO/sub 2/ (90%) might be excessively costly and cause operating problems for the industrial operator. More field evaluations of low excess air and low Btu gasification are required to validate these techniques for pollution control under industrial boiler operating conditions. The cost of two small boilers with no SO/sub 2/ controls was less than one large boiler of twice the capacity with SO/sub 2/ controls. The annual cost of operating and maintaining the control system accounted for the difference.

  1. Comparing Generic Drug Markets in Europe and the United States: Prices, Volumes, and Spending.

    Science.gov (United States)

    Wouters, Olivier J; Kanavos, Panos G; McKEE, Martin

    2017-09-01

    Policy Points: Our study indicates that there are opportunities for cost savings in generic drug markets in Europe and the United States. Regulators should make it easier for generic drugs to reach the market. Regulators and payers should apply measures to stimulate price competition among generic drugmakers and to increase generic drug use. To meaningfully evaluate policy options, it is important to analyze historical context and understand why similar initiatives failed previously. Rising drug prices are putting pressure on health care budgets. Policymakers are assessing how they can save money through generic drugs. We compared generic drug prices and market shares in 13 European countries, using data from 2013, to assess the amount of variation that exists between countries. To place these results in context, we reviewed evidence from recent studies on the prices and use of generics in Europe and the United States. We also surveyed peer-reviewed studies, gray literature, and books published since 2000 to (1) outline existing generic drug policies in European countries and the United States; (2) identify ways to increase generic drug use and to promote price competition among generic drug companies; and (3) explore barriers to implementing reform of generic drug policies, using a historical example from the United States as a case study. The prices and market shares of generics vary widely across Europe. For example, prices charged by manufacturers in Switzerland are, on average, more than 2.5 times those in Germany and more than 6 times those in the United Kingdom, based on the results of a commonly used price index. The proportion of prescriptions filled with generics ranges from 17% in Switzerland to 83% in the United Kingdom. By comparison, the United States has historically had low generic drug prices and high rates of generic drug use (84% in 2013), but has in recent years experienced sharp price increases for some off-patent products. There are policy

  2. Operational Ensemble River Forecasting in the United States and Australia: Practices and Challenges

    Science.gov (United States)

    Pagano, T. C.

    2012-04-01

    Operational river forecasts have been long produced to support water resources management in the United States and Australia. These forecasts cover a range of timescales from flash flooding (e.g. minutes to hours ahead) to seasonal (e.g. months ahead) and are generated by a range of statistical (e.g. regression-based) and dynamical (e.g. rainfall-runoff) model based techniques. Forecast uncertainty is commonly estimated operationally by using an ensemble of future precipitation scenarios and/or a measure of historical model error. Retrospective ensemble forecasting and the use of reforecasts for bias-adjustment and post-processing have become popular research topics and a few successful demonstration projects exist in both countries. Practical methods of post-processing, such as ensemble dressing, have been used to improve the probabilistic reliability of forecasts. The translation of predictions of probability distributions of streamflow into temporally and spatially consistent ensemble hydrographs remains an area for further development. However, probabilistic forecast communication and use remains a stumbling block for many. Furthermore, ensemble generation and post-processing typically require completely automated systems, making it difficult for humans to contribute their expertise to the forecasting process. This talk draws on ten years of experience as an operational forecaster with the US Department of Agriculture and as a developer of short-term flood forecasting systems to support the Australian Bureau of Meteorology.

  3. Scale-4 analysis of pressurized water reactor critical configurations: Volume 5, North Anna Unit 1 Cycle 5

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, S.M. [Oak Ridge National Lab., TN (United States); Suto, T. [Power Reactor and Nuclear Fuel Development Corp., Tokyo (Japan)]|[Oak Ridge National Lab., TN (United States)

    1996-10-01

    ANSI/ANS 8.1 requires that calculational methods for away-from- reactor (AFR) criticality safety analyses be validated against experiment. This report summarizes part of the ongoing effort to benchmark AFR criticality analysis methods using selected critical configurations from commercial PWRs. Codes and data in the SCALE-4 code system were used. This volume documents the SCALE system analysis of one reactor critical configuration for North Anna Unit 1 Cycle 5. The KENO V.a criticality calculations for the North Anna 1 Cycle 5 beginning-of-cycle model yielded a value for k{sub eff} of 1. 0040{+-}0.0005.

  4. A Formula for the Units to Satisfy an Operation's Desired Rate of Return in CVP Analysis--A Conceptual Approach

    Science.gov (United States)

    Anderson, Johann A.; Leese, Wallace R.

    2016-01-01

    A common formula presented in many managerial- and cost-accounting textbooks makes possible the determination of the quantity of units which must be produced and sold to generate a desired dollar-amount of operating income. This article addresses the question "What formula can be used to determine the quantity of units needed to yield a…

  5. 40 CFR Table 6 to Subpart Ppp of... - Process Vents From Continuous Unit Operations-Monitoring, Recordkeeping, and Reporting Requirements

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Process Vents From Continuous Unit Operations-Monitoring, Recordkeeping, and Reporting Requirements 6 Table 6 to Subpart PPP of Part 63... Subpart PPP of Part 63—Process Vents From Continuous Unit Operations—Monitoring, Recordkeeping, and...

  6. 40 CFR 60.1690 - What are the operating practice requirements for my municipal waste combustion unit?

    Science.gov (United States)

    2010-07-01

    ... requirements for my municipal waste combustion unit? 60.1690 Section 60.1690 Protection of Environment... SOURCES Emission Guidelines and Compliance Times for Small Municipal Waste Combustion Units Constructed on or Before August 30, 1999 Model Rule-Good Combustion Practices: Operating Requirements § 60.1690 What...

  7. Alternative Models of Service, Centralized Machine Operations. Phase II Report. Volume II.

    Science.gov (United States)

    Technology Management Corp., Alexandria, VA.

    A study was conducted to determine if the centralization of playback machine operations for the national free library program would be feasible, economical, and desirable. An alternative model of playback machine services was constructed and compared with existing network operations considering both cost and service. The alternative model was…

  8. Predicting the probability and volume of postwildfire debris flows in the intermountain western United States

    Science.gov (United States)

    Cannon, S.H.; Gartner, J.E.; Rupert, M.G.; Michael, J.A.; Rea, A.H.; Parrett, C.

    2010-01-01

    Empirical models to estimate the probability of occurrence and volume of postwildfire debris flows can be quickly implemented in a geographic information system (GIS) to generate debris-flow hazard maps either before or immediately following wildfires. Models that can be used to calculate the probability of debris-flow production from individual drainage basins in response to a given storm were developed using logistic regression analyses of a database from 388 basins located in 15 burned areas located throughout the U.S. Intermountain West. The models describe debris-flow probability as a function of readily obtained measures of areal burned extent, soil properties, basin morphology, and rainfall from short-duration and low-recurrence-interval convective rainstorms. A model for estimating the volume of material that may issue from a basin mouth in response to a given storm was developed using multiple linear regression analysis of a database from 56 basins burned by eight fires. This model describes debris-flow volume as a function of the basin gradient, aerial burned extent, and storm rainfall. Applications of a probability model and the volume model for hazard assessments are illustrated using information from the 2003 Hot Creek fire in central Idaho. The predictive strength of the approach in this setting is evaluated using information on the response of this fire to a localized thunderstorm in August 2003. The mapping approach presented here identifies those basins that are most prone to the largest debris-flow events and thus provides information necessary to prioritize areas for postfire erosion mitigation, warnings, and prefire management efforts throughout the Intermountain West.

  9. United States Air Force Graduate Student Research Program. 1989 Program Technical Report. Volume 3

    Science.gov (United States)

    1989-12-01

    just enough alignment in the organism passively along the field lines. Many animals, such as insects, fish, birds , reptiles , and mammals , have been...STUDENT RESEARCH PROGRAM 1989 PROGRAM TECHNICAL REPORT UNIVERSAL ENERGY SYSTEMS, INC. VOLUME III of III Program Director, UES Program Manager , AFOSR...Bldg. Assigned: Flight Dynamics Laboratory Wilberforce, OH 45384 (513) 376-6435 Dagmar Fertl Degree: BS Texas A&M Univ. Specialty: Biology Wildlife

  10. The United Nations Standing Force a Qualitative Analysis of Strategic and Operational Options for the United States

    Science.gov (United States)

    1993-06-01

    Council, has done .ch community...But, as much as the United Nations has done, it can do much more." Chaiaiing Times As the Bob Dylan song goes, "The...to our nation’s defense well into the twenty-first century. When Bob Dylan’s song was popular, it was also relevant. At that time, the United States

  11. Information as Power: An Anthology of Selected United States Army War College Student Papers. Volume 6

    Science.gov (United States)

    2012-05-01

    Baldor , “General Suggests ‘Secure Zone’ to Counter Cyber Threats,” Fayetteville Observer, September 24, 2010. According to Clarke and Knake, “of the...infrastructure is privately owned and operated. Baldor states that 85% of national infrastructure is owned and operated by private companies. Private...45. Rebecca Grant, Victory in Cyberspace (Arlington, VA: Air Force Association, 2007), 8. 46. Baldor , “General Suggests ‘Secure Zone.’” 47. Clarke

  12. Shuttle Ground Operations Efficiencies/Technologies Study (SGOE/T). Volume 5: Technical Information Sheets (TIS)

    Science.gov (United States)

    Scholz, A. L.; Hart, M. T.; Lowry, D. J.

    1987-01-01

    The Technology Information Sheet was assembled in database format during Phase I. This document was designed to provide a repository for information pertaining to 144 Operations and Maintenance Instructions (OMI) controlled operations in the Orbiter Processing Facility (OPF), Vehicle Assembly Building (VAB), and PAD. It provides a way to accumulate information about required crew sizes, operations task time duration (serial and/or parallel), special Ground Support Equipment (GSE). required, and identification of a potential application of existing technology or the need for the development of a new technolgoy item.

  13. Evaluation of the operational efficiency of pacifying police units in the state of Rio de Janeiro

    Directory of Open Access Journals (Sweden)

    Igor Rosa Dias de Jesus

    2014-05-01

    Full Text Available The Pacification Police Unit (UPP is a new model for public security and policing, aimed at ensuring local security and, above all, reduce, or even, extinguish violent crime linked to drug trafficking, and approach people and police. The purpose of this article is measuring the operational efficiency of all UPPs installed in the state of Rio de Janeiro by the beginning of 2011 by Data Envelopment Analysis (DEA. For this, it was used the CCR model – input-oriented – developed by Charnes, Cooper and Rhodes, which allows an objective assessment of the overall efficiency, identifying the sources of inefficiencies and the needed targets to achieve the efficiency in each UPP. The results converge to a reduction of the amount of policemen in all communities out of the efficiency frontier.

  14. Technical work plan for Surface Impoundments Operable Unit engineering support studies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    This document provides a comprehensive work plan which, when utilized as a data collection guide for field activities, will provide the necessary information required to complete a report on geotechnical properties of the sediments contained in the Surface Impoundments Operable Unit at Oak Ridge National Laboratory in Oak Ridge, Tennessee. Detailed guidance is provided for the following activities: collection of samples from the impoundments; compressive strength testing of the raw sediments; compressive strength testing of the structurally modified (lime and cement additives) sediments; testing for sediment physical properties and settling rates; testing for sediment dewatering characteristics; testing for radiation activity during the field work; testing for polymer additions that may enhance settling. The work plan additionally provides guidance and examples for the preparation of documents necessary to establish readiness for safe and satisfactory performance of the field activities. An outline for the format requested for a report of these data is also provided.

  15. 100-OL-1 Operable Unit Field Portable X-Ray Fluorescence (XRF) Analyzer Pilot Study Plans

    Energy Technology Data Exchange (ETDEWEB)

    Bunn, Amoret L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fritz, Brad G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wellman, Dawn M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-07-01

    A pilot study is being conducted to support the approval of the Remedial Investigation/Feasibility Study (RI/FS) Work Plan to evaluate the 100-OL-1 Operable Unit (OU) pre-Hanford orchard lands. Based on comments received by the U.S. Environmental Protection Agency (EPA) and Washington State Department of Ecology, the pilot study will evaluate the use of field portable X-ray fluorescence (XRF) spectrometry measurements for evaluating lead and arsenic concentrations on the soil surface as an indicator of past use of lead arsenate pesticide residue in the OU. The work will be performed in the field during the summer of 2014, and assist in the planning for the characterization activities in the RI/FS.

  16. Eielson Air Force Base operable unit 2 and other areas record of decision

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, R.E.; Smith, R.M.

    1994-10-01

    This decision document presents the selected remedial actions and no action decisions for Operable Unit 2 (OU2) at Eielson Air Force Base (AFB), Alaska, chosen in accordance with state and federal regulations. This document also presents the decision that no further action is required for 21 other source areas at Eielson AFB. This decision is based on the administrative record file for this site. OU2 addresses sites contaminated by leaks and spills of fuels. Soils contaminated with petroleum products occur at or near the source of contamination. Contaminated subsurface soil and groundwater occur in plumes on the top of a shallow groundwater table that fluctuates seasonally. These sites pose a risk to human health and the environment because of ingestion, inhalation, and dermal contact with contaminated groundwater. The purpose of this response is to prevent current or future exposure to the contaminated groundwater, to reduce further contaminant migration into the groundwater, and to remediate groundwater.

  17. Designing User Interfaces for Smart-Applications for Operating Rooms and Intensive Care Units

    Science.gov (United States)

    Kindsmüller, Martin Christof; Haar, Maral; Schulz, Hannes; Herczeg, Michael

    Today’s physicians and nurses working in operating rooms and intensive care units have to deal with an ever increasing amount of data. More and more medical devices are delivering information, which has to be perceived and interpreted in regard to patient status and the necessity to adjust therapy. The combination of high information load and insufficient usability creates a severe challenge for the health personnel with respect to proper monitoring of these devices respective to acknowledging alarms and timely reaction to critical incidents. Smart Applications are a new kind of decision support systems that incorporate medical expertise in order to help health personnel in regard to diagnosis and therapy. By means of a User Centered Design process of two Smart Applications (anaesthesia monitor display, diagnosis display), we illustrate which approach should be followed and which processes and methods have been successfully applied in fostering the design of usable medical devices.

  18. Performance of ESPs operating downstream from spray-drying desulphurisation units

    Energy Technology Data Exchange (ETDEWEB)

    Ollero, P.; Canadas, L.; Salvador, L. [Escuela Superior de Ingenieros Industrials, Sevilla (Spain)] [and others

    1995-06-01

    This paper summarizes data from a Spray Dryer/ESP pilot plant located at the Los Barrios Coal Power Plant (Cadiz, Spain). A series of tests has been conducted to evaluate the performance of an existing ESP operating downstream from a spray dryer in a retrofit application. A factorial design of experiments with two SO{sub 2} levels, two flyash load levels, three Ca/S ratios and three sulfur removal efficiencies, was run during a six-month experimental programme. A global and a field-by-field analysis of the performance of the pilot ESP has shown that the desulphurisation unit enhances ESP efficiency and reduces the emission level. No evidence of electrical dust reentrainment has been found.

  19. Analysis of hot spots in boilers of organic Rankine cycle units during transient operation

    DEFF Research Database (Denmark)

    Benato, A.; Kærn, Martin Ryhl; Pierobon, Leonardo

    2015-01-01

    This paper is devoted to the investigation of critical dynamic events causing thermochemical decompositionof the working fluid in organic Rankine cycle power systems. The case study is the plant of an oiland gas platform where one of the three gas turbines is combined with an organic Rankine cycle...... unit toincrease the overall energy conversion efficiency.The dynamic model of the plant is coupled with a one-dimensional model of the once-through boilerfed by the exhaust thermal power of the gas turbine. The heat exchanger model uses a distributedcross-flow physical topology and local correlations...... and fluid decomposition. It is demonstrated thatthe use of a spray attemperator can mitigate the problems of local overheating of the organic compound.As a practical consequence, this paper provides guidelines for safe and reliable operation of organicRankine cycle power modules on offshore installations....

  20. Thermo-physical performance prediction of the KSC Ground Operation Demonstration Unit for liquid hydrogen

    Science.gov (United States)

    Baik, J. H.; Notardonato, W. U.; Karng, S. W.; Oh, I.

    2015-12-01

    NASA Kennedy Space Center (KSC) researchers have been working on enhanced and modernized cryogenic liquid propellant handling techniques to reduce life cycle costs of propellant management system for the unique KSC application. The KSC Ground Operation Demonstration Unit (GODU) for liquid hydrogen (LH2) plans to demonstrate integrated refrigeration, zero-loss flexible term storage of LH2, and densified hydrogen handling techniques. The Florida Solar Energy Center (FSEC) has partnered with the KSC researchers to develop thermal performance prediction model of the GODU for LH2. The model includes integrated refrigeration cooling performance, thermal losses in the tank and distribution lines, transient system characteristics during chilling and loading, and long term steady-state propellant storage. This paper will discuss recent experimental data of the GODU for LH2 system and modeling results.

  1. 77 FR 50541 - STP Nuclear Operating Company, South Texas Project, Units 1 and 2; Application for Amendment to...

    Science.gov (United States)

    2012-08-21

    ... COMMISSION STP Nuclear Operating Company, South Texas Project, Units 1 and 2; Application for Amendment to... of STP Nuclear Operating Company (the licensee) to withdraw its application dated June 2, 2011 (ADAMS... ``Begin Web- based ADAMS Search.'' For problems with ADAMS, please contact the NRC's Public Document...

  2. 78 FR 45987 - Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to...

    Science.gov (United States)

    2013-07-30

    ... COMMISSION Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to... COLs were issued to Southern Nuclear Operating Company, Inc., and Georgia Power Company, Oglethorpe... Search.'' For problems with ADAMS, please contact the NRC's Public Document Room (PDR) reference staff...

  3. 78 FR 45989 - Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to...

    Science.gov (United States)

    2013-07-30

    ... COMMISSION Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to... COLs were issued to Southern Nuclear Operating Company, Inc., and Georgia Power Company, Oglethorpe..., select ``ADAMS Public Documents'' and then select ``Begin Web-based ADAMS Search.'' For problems...

  4. Operation planning studies for the integration of the 60 Hz Itaipu units in the Brazilian interconnected system

    Energy Technology Data Exchange (ETDEWEB)

    Chipp, H.J.; Oliveira, J.C.C. [ELETROBRAS, Rio de Janeiro, RJ (Brazil); Correa, L.R.A. [FURNAS, Rio de Janeiro, RJ (Brazil); Mendonca, W.C.; Marchi, R.D. [Itaipu Binacional, Foz do Iguacu, PR (Brazil); Botelho, M.J. [ELETROSUL, Curitiba, PR (Brazil)

    1987-12-31

    This paper describes the operation planning studies necessary to interconnect the first two 60 Hz generator units of the Itaipu power plant to the Brazilian interconnected system. The criteria, main problems identified and operative solutions encountered are presented in this paper. 10 refs., 4 figs., 5 tabs.

  5. 78 FR 37584 - U.S. Steel Tubular Products, Inc., Mckeesport Tubular Operations Division, Subsidiary of United...

    Science.gov (United States)

    2013-06-21

    ... Employment and Training Administration U.S. Steel Tubular Products, Inc., Mckeesport Tubular Operations Division, Subsidiary of United States Steel Corporation, Mckeesport, Pennsylvania; Notice of Amended... workers of U.S. Steel Tubular Products, McKeesport Tubular Operations Division, a subsidiary of...

  6. Telecommunications Research in the United States and Selected Foreign Countries: A Preliminary Survey. Volume I, Summary.

    Science.gov (United States)

    National Academy of Engineering, Washington, DC. Committee on Telecommunications.

    At the request of the National Science Foundation, the Panel on Telecommunications Research of the Committee on Telecommunications of the National Academy of Engineering has made a preliminary survey of the status and trends of telecommunications research in the United States and selected foreign countries. The status and trends were identified by…

  7. Fruit and Vegetable Production Unit for Plant Science Core Curriculum. Instructor's Guide. Volume 16, Number 3.

    Science.gov (United States)

    Stewart, Bob R.; Mullinix, Mark K.

    This curriculum guide, part of a plant science core curriculum, consists of materials for use in teaching a unit on fruit and vegetable production. Provided in the first part of the guide are a list of objectives, a bibliography, and a competency profile. The remainder of the guide consists of 11 lessons dealing with the following topics: planning…

  8. Our Environment. Language Arts Theme Units, Volume I. Cross Curricular Activities for Primary Grades.

    Science.gov (United States)

    McAllister, Elizabeth A.; Hildebrand, Joan M.; Ericson, Joann H.

    Suggesting that students in the primary grades can explore the world around them and practice valuable skills in spelling, reading, writing, communication, and language, this book presents cross-curricular units on the environment that reach diverse needs by working through emotional memory, deductive reasoning, and multiple intelligences.…

  9. People Around Us. Language Arts Theme Units, Volume V. Cross Curricular Activities for Primary Grades.

    Science.gov (United States)

    McAllister, Elizabeth A.; Hildebrand, Joan M.; Ericson, Joann H.

    Suggesting that students in the primary grades can explore the world around them and practice valuable skills in spelling, reading, writing, communication, and language, this book presents cross-curricular units on "people around us" that reach diverse needs by working through emotional memory, deductive reasoning, and multiple intelligences.…

  10. Intriguing Animals. Language Arts Theme Units, Volume IV. Cross Curricular Activities for Primary Grades.

    Science.gov (United States)

    McAllister, Elizabeth A.; Hildebrand, Joan M.; Ericson, Joann H.

    Suggesting that students in the primary grades can explore the world around them and practice valuable skills in spelling, reading, writing, communication, and language, this book presents cross-curricular units on intriguing animals that reach diverse needs by working through emotional memory, deductive reasoning, and multiple intelligences.…

  11. Food and Nutrition. Volume II. Units VI-VIII: Fruit, Fats, Vegetables, Legumes, Grains, Meats.

    Science.gov (United States)

    Honse, Elizabeth Linsenbardt

    These instructional materials are intended as a guide for the instructor of a secondary home economics course in food and nutrition. Topics covered in the three units are time, energy, and resource management; selection, care, preparation, and storage of food (seven lessons on dairy foods; fats and oils; cereals and breads; fruits and vegetables;…

  12. Mathematics for Junior High School, Volume 2, Student's Text, Part I. Unit 5.

    Science.gov (United States)

    Anderson, R. D.; And Others

    This fifth unit in the SMSG junior high mathematics series is a student text covering the following topics: rational numbers and coordinates; equations; scientific notation, decimals, and the metric system; constructions, congruent triangles, and the Pythagorean property; relative error; and real numbers. (DT)

  13. PRISM: Special Operations in a Chaotic World. Volume 6, Number 3

    Science.gov (United States)

    2016-12-07

    Many like to identify the special operator with kicking down doors and martial arts with advanced weapons. Those skills have actually been... art is the proper blend- ing of the special warfare and surgical strike CLEVELAND, LINDER, AND DEMPSEY 12 | FEATURES PRISM 6, no. 3 capabilities to...15 These effects and successes demonstrate the effective application of SOF operational art as a fiscally and politically sustainable strategic

  14. Ecological consistency of SSU rRNA-based operational taxonomic units at a global scale.

    Directory of Open Access Journals (Sweden)

    Thomas S B Schmidt

    2014-04-01

    Full Text Available Operational Taxonomic Units (OTUs, usually defined as clusters of similar 16S/18S rRNA sequences, are the most widely used basic diversity units in large-scale characterizations of microbial communities. However, it remains unclear how well the various proposed OTU clustering algorithms approximate 'true' microbial taxa. Here, we explore the ecological consistency of OTUs--based on the assumption that, like true microbial taxa, they should show measurable habitat preferences (niche conservatism. In a global and comprehensive survey of available microbial sequence data, we systematically parse sequence annotations to obtain broad ecological descriptions of sampling sites. Based on these, we observe that sequence-based microbial OTUs generally show high levels of ecological consistency. However, different OTU clustering methods result in marked differences in the strength of this signal. Assuming that ecological consistency can serve as an objective external benchmark for cluster quality, we conclude that hierarchical complete linkage clustering, which provided the most ecologically consistent partitions, should be the default choice for OTU clustering. To our knowledge, this is the first approach to assess cluster quality using an external, biologically meaningful parameter as a benchmark, on a global scale.

  15. Simulation of operational processes in hospital emergency units as lean healthcare tool

    Directory of Open Access Journals (Sweden)

    Andreia Macedo Gomes

    2017-07-01

    Full Text Available Recently, the Lean philosophy is gaining importance due to a competitive environment, which increases the need to reduce costs. Lean practices and tools have been applied to manufacturing, services, supply chain, startups and, the next frontier is healthcare. Most lean techniques can be easily adapted to health organizations. Therefore, this paper intends to summarize Lean practices and tools that are already being applied in health organizations. Among the numerous techniques and lean tools used, this research highlights the Simulation. Therefore, in order to understand the use of Simulation as a Lean Healthcare tool, this research aims to analyze, through the simulation technique, the operational dynamics of the service process of a fictitious hospital emergency unit. Initially a systematic review of the literature on the practices and tools of Lean Healthcare was carried out, in order to identify the main techniques practiced. The research highlighted Simulation as the sixth most cited tool in the literature. Subsequently, a simulation of a service model of an emergency unit was performed through the Arena software. As a main result, it can be highlighted that the attendants of the built model presented a degree of idleness, thus, they are able to atend a greater demand. As a last conclusion, it was verified that the emergency room is the process with longer service time and greater overload.

  16. Emergy Evaluation of Dwelling Operation in Five Housing Units of Montreal Island, Canada

    Directory of Open Access Journals (Sweden)

    Ricardo Enrique Vega-Azamar

    2017-04-01

    Full Text Available Sustainability of cities and the environmental implications of high resource utilization by the domestic sector are growing concerns related to urban regions. Well-informed urban planning decision-making is an essential tool to help in the task and, for that, an important point to consider is the influence of parameters like residential density and housing typology on the intensity of resource utilization. Emergy synthesis, a life-cycle energy analysis methodological approach that considers the interaction of natural and human-made flows, was used to evaluate the environmental support for dwelling operational stage in five typical present-day housing units on the island of Montreal. As expected, resource utilization, measured as total emergy used, was positively correlated to housing unit size both with respect to number of occupants and dwelling size. Results suggest that variables affecting notably the intensity of resource utilization are per household income and per dweller habitable space and, while a higher income increased per capita emergy in all cases, increasing space availability per resident did not result in a decrease of empower density after 50 m2/person. Future work should consider lower and higher densities and analyses at the scale of blocks, neighborhoods and urban planning zones.

  17. Tug fleet and ground operations schedules and controls. Volume 1: Executive summary

    Science.gov (United States)

    1975-01-01

    This study presents Tug Fleet and Ground Operations Schedules and Controls plan. This plan was developed and optimized out of a combination of individual Tug program phased subplans, special emphasis studies, contingency analyses and sensitivity analyses. The subplans cover the Tug program phases: (1) Tug operational, (2) Interim Upper Stage (IUS)/Tug fleet utilization, (3) and IUS/Tug payload integration, (4) Tug site activation, (5) IUS/Tug transition, (6) Tug acquisition. Resource requirements (facility, GSE, TSE, software, manpower, logistics) are provided in each subplan, as are appropriate Tug processing flows, active and total IUS and Tug fleet requirements, fleet management and Tug payload integration concepts, facility selection recommendations, site activation and IUS to Tug transition requirements. The impact of operational concepts on Tug acquisition is assessed and the impact of operating Tugs out of KSC and WTR is analyzed and presented showing WTR as a delta. Finally, cost estimates for fleet management and ground operations of the DDT&E and operational phases of the Tug program are given.

  18. Limited field investigation report for the 100-HR-1 Operable Unit

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    This limited field investigation (LFI) report summarizes the data collection and analysis activities conducted during the 100-HR-1 Source Operable Unit LFI and the associated qualitative risk assessment (QRA) (WHC 1993a), and makes recommendations on the continued candidacy of high-priority sites for interim remedial measures (IRM). The results and recommendations presented in this report are generally independent of future land use scenarios. A LFI Report is required, in accordance with the HPPS, when waste sites are to be considered for IRMs. The LFI is an integral part of the remedial investigation/feasibility study (RI/FS) or Resource Conservation and Recovery Act (RCRA) facility investigation/corrective measures study (RFI/CMS) and process and functions as a focused RI or RFI for selection of IRMs. The purpose of the report is to identify those sites that are recommended to remain as candidates for IRMs, provide a preliminary summary of site characterization studies, refine the conceptual model as needed, identify contaminant- and location-specific applicable or relevant and appropriate requirements (ARA), and provide a qualitative assessment of the risks associated with the sites. This assessment includes consideration of whether contaminant concentrations pose an unacceptable risk that warrants action through IRMs. The 100-HR-1 unit encompasses approximately 100 acres adjacent to the Columbia River shoreline. It contains waste units associated with the original plant facilities constructed to support the H Reactor. The area also contains evaporation basins which received liquid process wastes and nonroutine deposits of chemical wastes from the 300 Area, where fuel elements for the N Reactor were produced.

  19. Can a stepwise steady flow computational fluid dynamics model reproduce unsteady particulate matter separation for common unit operations?

    Science.gov (United States)

    Pathapati, Subbu-Srikanth; Sansalone, John J

    2011-07-01

    Computational fluid dynamics (CFD) is emerging as a model for resolving the fate of particulate matter (PM) by unit operations subject to rainfall-runoff loadings. However, compared to steady flow CFD models, there are greater computational requirements for unsteady hydrodynamics and PM loading models. Therefore this study examines if integrating a stepwise steady flow CFD model can reproduce PM separation by common unit operations loaded by unsteady flow and PM loadings, thereby reducing computational effort. Utilizing monitored unit operation data from unsteady events as a metric, this study compares the two CFD modeling approaches for a hydrodynamic separator (HS), a primary clarifier (PC) tank, and a volumetric clarifying filtration system (VCF). Results indicate that while unsteady CFD models reproduce PM separation of each unit operation, stepwise steady CFD models result in significant deviation for HS and PC models as compared to monitored data; overestimating the physical size requirements of each unit required to reproduce monitored PM separation results. In contrast, the stepwise steady flow approach reproduces PM separation by the VCF, a combined gravitational sedimentation and media filtration unit operation that provides attenuation of turbulent energy and flow velocity.

  20. China's first home-made large ethylene unit put into operation in Daqing%China's first home-made large ethylene unit put into operation in Daqing

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    On October 5, the newly built 600kt/a ethylene unit at Daqing Petrochemical, a key part of the company's 1.2Mt/a ethylene expansion/upgrading project, turned out qualified products, indicating the successful industrialization of the packaged technology for China's first home-made large ethylene unit. This enables China to be independent from importing technologies for ethylene production which lasted for halfa century.

  1. Journal of Special Operations Medicine. Volume 1, Edition 3, Fall 2001

    Science.gov (United States)

    2001-01-01

    City Federal Building1 and United States embas- sies in Kenya and Tanzania provide examples of the types of injuries and casualty evacuation problems...Medicine 67 may cause anxiety and rapid heart rate. Also,m epi- nephrine can be aerosolized and breathed into the lungs for asthma and other reactive

  2. Joint Center for Operational Analysis Journal. Volume 12, Issue 3, Winter 2010-2011

    Science.gov (United States)

    2011-01-01

    rediscovery of the obvious - we need to move on. Assumptions Far more pernicious in their impact are assumptions dressed in "lessons learned clothing...the rates for the United States or Western Europe.24 Maternal and infant mortality from pneumonia were ranked as second worst in the country in

  3. Remedial investigation/feasibility study report for Lower Watts Bar Reservoir Operable Unit

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-03-01

    This document is the combined Remedial Investigation and Feasibility Study Report for the lower Watts Bar Reservoir (LWBR) Operable Unit (OU). The LWBR is located in Roane, Rhea, and Meigs counties, Tennessee, and consists of Watts Bar Reservoir downstream of the Clinch river. This area has received hazardous substances released over a period of 50 years from the US Department of Energy`s Oak Ridge Reservation (ORR), a National Priority List site established under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). As required by this law, the ORR and all off-site areas that have received contaminants, including LWBR, must be investigated to determine the risk to human health and the environment resulting from these releases, the need for any remedial action to reduce these risks, and the remedial actions that are most feasible for implementation in this OU. Contaminants from the ORR are primarily transported to the LWBR via the Clinch River. There is little data regarding the quantities of most contaminants potentially released from the ORR to the Clinch River, particularly for the early years of ORR operations. Estimates of the quantities released during this period are available for most radionuclides and some inorganic contaminants, indicating that releases 30 to 50 years ago were much higher than today. Since the early 1970s, the release of potential contaminants has been monitored for compliance with environmental law and reported in the annual environmental monitoring reports for the ORR.

  4. Some assembly required: constructing the elementary units of store-operated Ca2+ entry.

    Science.gov (United States)

    Wu, Minnie M; Luik, Riina M; Lewis, Richard S

    2007-08-01

    The means by which Ca(2+) store depletion evokes the opening of store-operated Ca(2+) channels (SOCs) in the plasma membrane of excitable and non-excitable cells has been a longstanding mystery. Indirect evidence has supported local interactions between the ER and SOCs as well as long-range interactions mediated through a diffusible activator. The recent molecular identification of the ER Ca(2+) sensor (STIM1) and a subunit of the CRAC channel (Orai1), a prototypic SOC, has now made it possible to visualize directly the sequence of events that links store depletion to CRAC channel opening. Following store depletion, STIM1 moves from locations throughout the ER to accumulate in ER subregions positioned within 10-25nm of the plasma membrane. Simultaneously, Orai1 gathers at discrete sites in the plasma membrane directly opposite STIM1, resulting in local CRAC channel activation. These new studies define the elementary units of store-operated Ca(2+) entry, and reveal an unprecedented mechanism for channel activation in which the stimulus brings a channel and its activator/sensor together for interaction across apposed membrane compartments. We discuss the implications of this choreographic mechanism with regard to Ca(2+) dynamics, specificity of Ca(2+) signaling, and the existence of a specialized ER subset dedicated to the control of the CRAC channel.

  5. Remedial design work plan for Lower East Fork Poplar Creek Operable Unit, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The Remedial Design Work Plan (RDWP) for Lower East Fork Poplar Creek (EFPC) Operable Unit (OU) in Oak Ridge, Tennessee. This remedial action fits into the overall Oak Ridge Reservation (ORR) cleanup strategy by addressing contaminated floodplain soil. The objective of this remedial action is to minimize the risk to human health and the environment from contaminated soil in the Lower EFPC floodplain pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) and the Federal Facility Agreement (FFA) (1992). In accordance with the FFA, a remedial investigation (RI) (DOE 1994a) and a feasibility study (DOE 1994b) were conducted to assess contamination of the Lower EFPC and propose remediation alternatives. The remedial investigation determined that the principal contaminant is mercury, which originated from releases during Y-12 Plant operations, primarily between 1953 and 1963. The recommended alternative by the feasibility study was to excavate and dispose of floodplain soils contaminated with mercury above the remedial goal option. Following the remedial investigation/feasibility study, and also in accordance with the FFA, a proposed plan was prepared to more fully describe the proposed remedy.

  6. Operable Unit 1 remedial investigation report, Eielson Air Force Base, Alaska

    Energy Technology Data Exchange (ETDEWEB)

    Gilmore, T.J.; Fruland, R.M.; Liikala, T.L. [and others

    1994-06-01

    This remedial investigation report for operable Unit 1 (OU-1) at Eielson Air Force Base presents data, calculations, and conclusions as to the nature and extent of surface and subsurface contamination at the eight source areas that make up OU-1. The information is based on the 1993 field investigation result and previous investigations. This report is the first in a set of three for OU-1. The other reports are the baseline risk assessment and feasibility study. The information in these reports will lead to a Record of Decision that will guide and conclude the environmental restoration effort for OU-1 at Eielson Air Force Base. The primary contaminants of concern include fuels and fuel-related contaminants (diesel; benzene, toluene, ethylbenzene, and xylene; total petroleum hydrocarbon; polycyclic aromatic hydrocarbons), maintenance-related solvents and cleaners (volatile chlorinated hydrocarbons such as trichloroothylene), polychlorinated biphenyls, and dichlorodiphenyltrichloroethane (DDT). The origins of contaminants of concern include leaks from storage tanks, drums and piping, and spills. Ongoing operations and past sitewide practices also contribute to contaminants of concern at OU-1 source areas. These include spraying mixed oil and solvent wastes on unpaved roads and aerial spraying of DDT.

  7. Two-Dimensional Simulation of Mass Transfer in Unitized Regenerative Fuel Cells under Operation Mode Switching

    Directory of Open Access Journals (Sweden)

    Lulu Wang

    2016-01-01

    Full Text Available A two-dimensional, single-phase, isothermal, multicomponent, transient model is built to investigate the transport phenomena in unitized regenerative fuel cells (URFCs under the condition of switching from the fuel cell (FC mode to the water electrolysis (WE mode. The model is coupled with an electrochemical reaction. The proton exchange membrane (PEM is selected as the solid electrolyte of the URFC. The work is motivated by the need to elucidate the complex mass transfer and electrochemical process under operation mode switching in order to improve the performance of PEM URFC. A set of governing equations, including conservation of mass, momentum, species, and charge, are considered. These equations are solved by the finite element method. The simulation results indicate the distributions of hydrogen, oxygen, water mass fraction, and electrolyte potential response to the transient phenomena via saltation under operation mode switching. The hydrogen mass fraction gradients are smaller than the oxygen mass fraction gradients. The average mass fractions of the reactants (oxygen and hydrogen and product (water exhibit evident differences between each layer in the steady state of the FC mode. By contrast, the average mass fractions of the reactant (water and products (oxygen and hydrogen exhibit only slight differences between each layer in the steady state of the WE mode. Under either the FC mode or the WE mode, the duration of the transient state is only approximately 0.2 s.

  8. Large-Scale Pumping Test Recommendations for the 200-ZP-1 Operable Unit

    Energy Technology Data Exchange (ETDEWEB)

    Spane, Frank A.

    2010-09-08

    CH2M Hill Plateau Remediation Company (CHPRC) is currently assessing aquifer characterization needs to optimize pump-and-treat remedial strategies (e.g., extraction well pumping rates, pumping schedule/design) in the 200-ZP-1 operable unit (OU), and in particular for the immediate area of the 241 TX-TY Tank Farm. Specifically, CHPRC is focusing on hydrologic characterization opportunities that may be available for newly constructed and planned ZP-1 extraction wells. These new extraction wells will be used to further refine the 3-dimensional subsurface contaminant distribution within this area and will be used in concert with other existing pump-and-treat wells to remediate the existing carbon tetrachloride contaminant plume. Currently, 14 extraction wells are actively used in the Interim Record of Decision ZP-1 pump-and-treat system for the purpose of remediating the existing carbon tetrachloride contamination in groundwater within this general area. As many as 20 new extraction wells and 17 injection wells may be installed to support final pump-and-treat operations within the OU area. It should be noted that although the report specifically refers to the 200-ZP-1 OU, the large-scale test recommendations are also applicable to the adjacent 200-UP-1 OU area. This is because of the similar hydrogeologic conditions exhibited within these two adjoining OU locations.

  9. 100-OL-1 Operable Unit Pilot Study: XRF Evaluation of Select Pre-Hanford Orchards

    Energy Technology Data Exchange (ETDEWEB)

    Bunn, Amoret L.; Fritz, Brad G.; Pulsipher, Brent A.; Gorton, Alicia M.; Bisping, Lynn E.; Brandenberger, Jill M.; Pino, Christian; Martinez, Dominique M.; Rana, Komal; Wellman, Dawn M.

    2014-11-20

    Prior to the acquisition of land by the U.S. Department of War in February 1943 and the creation of the Hanford Site, the land along the Columbia River was home to over 1000 people. Farming and orchard operations by both homesteaders and commercial organizations were prevalent. Orchard activities and the associated application of lead arsenate pesticide ceased in 1943, when residents were moved from the Hanford Site at the beginning of the Manhattan Project. Today, the residues from historical application of lead arsenate pesticide persist in some locations on the Hanford Site. In 2012, the U.S. Department of Energy, U.S. Environmental Protection Agency, and Washington State Department of Ecology established the 100-OL-1 Operable Unit (OU) through the Hanford Federal Facility Agreement and Consent Order, known as the Tri-Party Agreement. The pre-Hanford orchard lands identified as the 100-OL-1 OU are located south of the Columbia River and east of the present-day Vernita Bridge, and extend southeast to the former Hanford townsite. The discontinuous orchard lands within 100-OL-1 OU are approximately 20 km2 (5000 ac). A pilot study was conducted to support the approval of the remedial investigation/feasibility study work plan to evaluate the 100-OL-1 OU. This pilot study evaluated the use of a field portable X-ray fluorescence (XRF) analyzer for evaluating lead and arsenic concentrations on the soil surface as an indicator of lead arsenate pesticide residues in the OU. The objectives of the pilot study included evaluating a field portable XRF analyzer as the analytical method for decision making, estimating the nature and extent of lead and arsenic in surface soils in four decision units, evaluating the results for the purpose of optimizing the sampling approach implemented in the remedial investigation, and collecting information to improve the cost estimate and planning the cultural resources review for sampling activities in the remedial investigation. Based on

  10. Quantification of respiratory depression during pre-operative administration of midazolam using a non-invasive respiratory volume monitor.

    Science.gov (United States)

    Gonzalez Castro, Luis N; Mehta, Jaideep H; Brayanov, Jordan B; Mullen, Gary J

    2017-01-01

    Pre-operative administration of benzodiazepines can cause hypoventilation-a decrease in minute ventilation (MV)-commonly referred to as "respiratory compromise or respiratory depression." Respiratory depression can lead to hypercarbia and / or hypoxemia, and may heighten the risk of other respiratory complications. Current anesthesia practice often places patients at risk for respiratory complications even before surgery, as respiratory monitoring is generally postponed until the patient is in the operating room. In the present study we examined and quantified the onset of respiratory depression following the administration of a single dose of midazolam in pre-operative patients, using a non-invasive respiratory volume monitor that reports MV, tidal volume (TV), and respiratory rate (RR). Impedance-based Respiratory Volume Monitor (RVM) data were collected and analyzed from 30 patients prior to undergoing orthopedic or general surgical procedures. All patients received 2.0 mg of midazolam intravenously at least 20 minutes prior to the induction of anesthesia and the effects of midazolam on the patient's respiratory function were analyzed. Within 15 minutes of midazolam administration, we noted a significant decrease in both MV (average decrease of 14.3% ± 5.9%, pmidazolam administration on clinically significant respiratory parameters (MV, TV and RR) using a non-invasive RVM, uncovering that the respiratory depressive effect of benzodiazepines affect primarily TV rather than RR. Such respiratory monitoring data provide the opportunity for individualizing dosing and adjustment of clinical interventions, especially important in elderly patients. With additional respiratory data, clinicians may be able to better identify and quantify respiratory depression, reduce adverse effects, and improve overall patient safety.

  11. Performance characteristics of advanced volume phase holographic gratings for operation in the near infrared

    Science.gov (United States)

    Arns, James A.

    2016-07-01

    Volume phase holographic (VPH) gratings are proven dispersing elements in astronomical spectrographs over the visible spectrum. VPH gratings have also been successfully deployed for use at cryogenic temperatures. Recent advances in production technology now permit the production of gratings for use in the near infrared up to 2450 nm at cryogenic conditions. This paper describes the requirements of VPH gratings for use in the H (wavelengths from 1500 nm to 1800 nm) and K (wavelengths from 1950 nm to 2450 nm) bands, gives the theoretical performances of diffraction efficiency for the production designs and presents the measured performances on the production gratings

  12. Impact of selection of cord blood units from the United States and swiss registries on the cost of banking operations.

    Science.gov (United States)

    Bart, Thomas; Boo, Michael; Balabanova, Snejana; Fischer, Yvonne; Nicoloso, Grazia; Foeken, Lydia; Oudshoorn, Machteld; Passweg, Jakob; Tichelli, Andre; Kindler, Vincent; Kurtzberg, Joanne; Price, Thomas; Regan, Donna; Shpall, Elizabeth J; Schwabe, Rudolf

    2013-02-01

    Over the last 2 decades, cord blood (CB) has become an important source of blood stem cells. Clinical experience has shown that CB is a viable source for blood stem cells in the field of unrelated hematopoietic blood stem cell transplantation. Studies of CB units (CBUs) stored and ordered from the US (National Marrow Donor Program (NMDP) and Swiss (Swiss Blood Stem Cells (SBSQ)) CB registries were conducted to assess whether these CBUs met the needs of transplantation patients, as evidenced by units being selected for transplantation. These data were compared to international banking and selection data (Bone Marrow Donors Worldwide (BMDW), World Marrow Donor Association (WMDA)). Further analysis was conducted on whether current CB banking practices were economically viable given the units being selected from the registries for transplant. It should be mentioned that our analysis focused on usage, deliberately omitting any information about clinical outcomes of CB transplantation. A disproportionate number of units with high total nucleated cell (TNC) counts are selected, compared to the distribution of units by TNC available. Therefore, the decision to use a low threshold for banking purposes cannot be supported by economic analysis and may limit the economic viability of future public CB banking. We suggest significantly raising the TNC level used to determine a bankable unit. A level of 125 × 10(7) TNCs, maybe even 150 × 10(7) TNCs, might be a viable banking threshold. This would improve the return on inventory investments while meeting transplantation needs based on current selection criteria.

  13. United States Air Force Summer Faculty Research Program (1987). Program Technical Report. Volume 2.

    Science.gov (United States)

    1987-12-01

    level. Secondly, the Gibbs free energy at a given location in the sample is taken to be comprised of two main contributions: the free energy per unit...ise tneab Itre ldt bs ofidth vv)tc, l ,ecto e sCin trw C’narv e hasi Proab. em ofeaccowies toihte r ptheent i stu o yn" o fase zero> mTy e

  14. Summary of Notifiable Diseases, United States, 1995. Volume 44/No. 53

    Science.gov (United States)

    2007-11-02

    Encephalitis, eastern equine Encephalitis, St. Louis Encephalitis, western equine Escherlchia co//0157:H7 Gonorrhea Haemophilus influenzae , invasive...now recognized as a pan-American viral zoonosis caused by Sin Nombre virus and other New World hantaviruses. The identi- fied rodent reservoirs for...H7 Haemophilus influenzae , invasive Area Chlamydia*t Cholera NETSSS PHLIS1 Gonorrhea 1’ United States 477,638 23 2,139 1,531 392,848 1,180 New

  15. United States Air Force Graduate Student Summer Support Program 1986. Program Technical Report. Volume 2

    Science.gov (United States)

    1986-12-01

    PROGRAM PROJECT TASK WORK UNIT Building 410 ELEMENT NO. NO. NO. NO. Bolling AFB, DC 20332 6l1O2F 33(. 5 11. TITLE (Inclusde Security Clasification ) us...H Byfr *(.. *’i ~rvs Vari ance arlu jt s A~ :i Z. 1r _ _:_F ’easureamerts cf EEG Act i vi t Y, �. 4,, Carie . f.R. G3. anrd ;:rost, .£.*"QSil

  16. Monticello Mill Tailings Site, Operable Unit lll, Annual Groundwater Report, May 2015 Through April 2016

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Jason [USDOE Office of Legacy Management (LM), Washington, DC (United States); Smith, Fred [Navarro Research and Engineering, Oak Ridge, TN (United States)

    2016-10-01

    This report provides the annual analysis of water quality restoration progress, cumulative through April 2016, for Operable Unit (OU) III, surface water and groundwater, of the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Monticello Mill Tailings Site (MMTS). The MMTS is a Comprehensive Environmental Response, Compensation, and Liability Act National Priorities List site located in and near the city of Monticello, San Juan County, Utah. MMTS comprises the 110-acre site of a former uranium- and vanadium-ore-processing mill (mill site) and 1700 acres of surrounding private and municipal property. Milling operations generated 2.5 million cubic yards of waste (tailings) from 1942 to 1960. The tailings were impounded at four locations on the mill site. Inorganic constituents in the tailings drained from the impoundments to contaminate local surface water (Montezuma Creek) and groundwater in the underlying alluvial aquifer. Mill tailings dispersed by wind and water also contaminated properties surrounding and downstream of the mill site. Remedial actions to remove and isolate radiologically contaminated soil, sediment, and debris from the former mill site, Operable Unit I (OU I), and surrounding properties (OU II) were completed in 1999 with the encapsulation of the wastes in an engineered repository located on DOE property 1 mile south of the former mill site. This effectively removed the primary source of groundwater contamination; however, contamination of groundwater and surface water remains within OU III at levels that exceed water quality protection standards. Uranium is the primary contaminant of concern (COC). LM implemented monitored natural attenuation with institutional controls as the OU III remedy in 2004. Because groundwater restoration proceeded more slowly than expected and did not meet performance criteria established in the OU III Record of Decision (June 2004), LM implemented a contingency action in 2009 by an Explanation of

  17. Typhoid perforation: Post-operative Intensive Care Unit care and outcome

    Directory of Open Access Journals (Sweden)

    Mukaila Oyegbade Akinwale

    2016-01-01

    Full Text Available Background: Typhoid perforation ileitis is a serious complication of typhoid fever, a common and unfortunate health problem in a resource-poor country like Nigeria. Following bowel perforation, treatment is usually by simple closure or bowel resection and anastomosis after adequate aggressive fluid resuscitation and electrolyte correction. Postoperatively, some of these patients do require management in Intensive Care Unit (ICU on account of sepsis or septic shock and to improve survival. Patients and Methods: This is a prospective observational study in which 67 consecutive patients who had exploratory laparotomy for typhoid perforation between August 2009 and October 2012 in the main operating theatre of the University College Hospital, Ibadan, were studied. The attending anaesthetists had the freedom of choosing the appropriate anaesthetic drugs depending on the patients' clinical condition. The reason for admission into the ICU, the types of organ support required and outcomes were recorded. Results: Twenty-five patients (37.3% out of 67 required critical care. Reasons for admission among others included poor respiratory effort, hypotension, septic shock and delayed recovery from anaesthesia. Twenty-one patients (84% required mechanical ventilation with a mean duration of 2.14 days (range 1–5 days. Fourteen patients required ionotropic support and the length of ICU stay ranged from 1 to 15 days (mean 4.32 days. Nineteen patients (76% were successfully managed and discharged to the ward while 24% (6 patients mortality rate was recorded. Conclusion: This study showed high rate of post-operative ICU admission in patients with typhoid perforation with a high demand for critical care involving mechanical ventilation and ionotropic support. In centres that manage patients presenting with typhoid ileitis and perforation, post-operative critical care should be available.

  18. Typhoid perforation: Post-operative Intensive Care Unit care and outcome.

    Science.gov (United States)

    Akinwale, Mukaila Oyegbade; Sanusi, Arinola A; Adebayo, Oluwaseun K

    2016-01-01

    Typhoid perforation ileitis is a serious complication of typhoid fever, a common and unfortunate health problem in a resource-poor country like Nigeria. Following bowel perforation, treatment is usually by simple closure or bowel resection and anastomosis after adequate aggressive fluid resuscitation and electrolyte correction. Postoperatively, some of these patients do require management in Intensive Care Unit (ICU) on account of sepsis or septic shock and to improve survival. This is a prospective observational study in which 67 consecutive patients who had exploratory laparotomy for typhoid perforation between August 2009 and October 2012 in the main operating theatre of the University College Hospital, Ibadan, were studied. The attending anaesthetists had the freedom of choosing the appropriate anaesthetic drugs depending on the patients' clinical condition. The reason for admission into the ICU, the types of organ support required and outcomes were recorded. Twenty-five patients (37.3%) out of 67 required critical care. Reasons for admission among others included poor respiratory effort, hypotension, septic shock and delayed recovery from anaesthesia. Twenty-one patients (84%) required mechanical ventilation with a mean duration of 2.14 days (range 1-5 days). Fourteen patients required ionotropic support and the length of ICU stay ranged from 1 to 15 days (mean 4.32 days). Nineteen patients (76%) were successfully managed and discharged to the ward while 24% (6 patients) mortality rate was recorded. This study showed high rate of post-operative ICU admission in patients with typhoid perforation with a high demand for critical care involving mechanical ventilation and ionotropic support. In centres that manage patients presenting with typhoid ileitis and perforation, post-operative critical care should be available.

  19. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 1: Title II design report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. Volume 1 provides a comprehensive narrative description of the proposed facility and systems, the basis for each of the systems design, and the engineering assessments that were performed to support the technical basis of the Title II design. The intent of the system description presented is to provide WHC an understanding of the facilities and equipment provided and the A/E`s perspective on how these systems will operate.

  20. MPS Solidification Model. Volume 2: Operating guide and software documentation for the unsteady model

    Science.gov (United States)

    Maples, A. L.

    1981-01-01

    The operation of solidification Model 2 is described and documentation of the software associated with the model is provided. Model 2 calculates the macrosegregation in a rectangular ingot of a binary alloy as a result of unsteady horizontal axisymmetric bidirectional solidification. The solidification program allows interactive modification of calculation parameters as well as selection of graphical and tabular output. In batch mode, parameter values are input in card image form and output consists of printed tables of solidification functions. The operational aspects of Model 2 that differ substantially from Model 1 are described. The global flow diagrams and data structures of Model 2 are included. The primary program documentation is the code itself.

  1. Large truncated Toeplitz matrices, Toeplitz operators, and related topics the Albrecht Böttcher anniversary volume

    CERN Document Server

    Ehrhardt, Torsten; Karlovich, Alexei; Spitkovsky, Ilya

    2017-01-01

    This book presents a collection of expository and research papers on various topics in matrix and operator theory, contributed by several experts on the occasion of Albrecht Böttcher’s 60th birthday. Albrecht Böttcher himself has made substantial contributions to the subject in the past. The book also includes a biographical essay, a complete bibliography of Albrecht Böttcher’s work and brief informal notes on personal encounters with him. The book is of interest to graduate and advanced undergraduate students majoring in mathematics, researchers in matrix and operator theory as well as engineers and applied mathematicians.

  2. Energy study of rail passenger transportation. Volume 2. Description of operating systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, C.; Ellis, H. T.; Wilhelm, J. P.

    1979-08-01

    The rail passenger systems of the US are described in terms of selected physical, operating, and economic characteristics, and relates services rendered to energy usage and costs. Rail passenger transportation exists in 4 distinct forms: intercity railroads, suburban railroads, heavy-rail transit, and light-rail transit. Each form varies in technical equipment, design of facilities, operating practices, size of systems. Specific data for the national rail passenger network and the Boston, Chicago, Cleveland, New York, Philadelphia, Pittsburgh, and San Francisco regions and the Washington Metropolitan area transit authority are presented.

  3. Hazard Assessment Computer System HACS/UIM Users’ Operation Manual. Volume II.

    Science.gov (United States)

    1981-09-01

    code for use with HACS given either a compound or synonyn name. A-i F- ............. CHEMICAL RECOGNITION CODE CHEMICAL. NAME AAC ACETIC ACID AAD...LEAD/GAL.) GCM GLYCIDYL METHACRYLATE GCR GLYCERINE GCS GASOLINE: CASINGHEAD GLA GALLIC ACID GOC GAS OIL: CRACKED GOS GLYOXAL, 40% SOLUTION GPL GASOLINE...of Transportation in the interest of information exchange. The UnitedStates Government assumes no liability for its contents or use thereof. The

  4. Interagency, Intergovernmental Organization, and Nongovernmental Organization Coordination During Joint Operations. Volume 2

    Science.gov (United States)

    2006-03-17

    Refugee Service/USA MAP International Pact Salvation Army World Service Office, The Save the Children Stop Hunger Now, Inc. United Methodist...prostitution and street children . k. To reunite unaccompanied child victims of conflict with their families. l. To raise public awareness of child labor. m...agricultural sectors and the probable effects of different policy decisions. A -A -2 A nnex A to A ppendix A JP 3-08 Figure A-A-1. Department of

  5. Joint Center for Operational Analysis Quarterly Bulletin. Volume 8, Issue 3, September 2006

    Science.gov (United States)

    2006-09-01

    in Iraq,” 16. 25 Urbano , Fighting in the Streets: A Manual of Urban Guerilla Warfare (New Jersey: Barricade Books, Inc. 1991), 10, 12. Robert Tabor...that they have fielded discrete units charged with “nonviolent action” (e.g., strikes in the transportation sector) to supplement “violent action...In Colombia , where the US is similarly involved in support of the counterinsurgency, the insurgents of FARC (Fuerzas Armadas Revolucionarias de

  6. The Bulletin of Military Operations Research. PHALANX. Volume 31, Number 4. December 1998.

    Science.gov (United States)

    1998-12-01

    President NATALIE S. ADDISON TOM FRAZIER VPfor Administration GREG WALLICK JIM LOWE Printed On Recycled Paper The PHALANX (ISSN 0195-1920) is...Executive award, Operations, HQ USAF, delivered an Kimball ," PHALANX, September, and three Department of the Army Excep- address on Analysis Lessons

  7. Journal of Special Operations Medicine, Volume 4, Edition 4, Fall 2004

    Science.gov (United States)

    2004-01-01

    PERSONAE CARE - Cooperative for Assistance and Relief Everywhere CMOC - Civil Military Operations Center CRS - Catholic Relief Services DART...Duty Jack Singlaub (MG Ret) Hazardous Duty David H Hackworth (COL) & Tom Mathews Hell In A Very Small Place Bernard Fall (Siege of Dien Bien Phu) Ho

  8. Screening Analysis : Volume 2, Impact Results (Columbia River System Operation Review).

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    Detailed results from all of the work groups are presented in this chapter. Ninety alternatives were analyzed during the screening process. Three of the alternative represent various base cases and are used for comparison purposes. The other 87 alternatives represent a wide variety of operational possibilities ranging from current operations to emphasizing a single river use to compromise operations that attempt to accommodate the multiple uses. Every possible alternative suggested during the screening phase was considered. Each alternative was given an abbreviated name, a number and assigned by ROSE to either the Corps (C) or BPA (B) for hydroregulation modeling. A list of the alternatives with its number and hydroregulation assignment is given below. The results in this chapter are presented in numerical order. The first 3 letters in the name identify which work group suggested the alternative. The format for the results includes a brief description of each alternative, a tabulation of the screening calculations organized by work group, and observations/comments on the alternative by the work groups. The description summarizes the key operational requirements for the alternative and was taken directly from the instructions given to the hydroregulation modelers.

  9. NATO Guide for Judgement-Based Operational Analysis in Defence Decision Making : Client-Oriented Volume

    NARCIS (Netherlands)

    Wijnmalen, D.J.D.; et al

    2012-01-01

    Judgment plays an important role in all Operational Analysis (OA). NATO practitioners have determined that approaches in OA that are based on human judgement are increasingly critical to defence decision making. The purpose of the NATO Guide for Judgement-Based OA in Defence Decision Making is to cr

  10. Joint Center for Operational Analysis Quarterly Bulletin. Volume 7, Issue 3, June 2005

    Science.gov (United States)

    2005-06-01

    War Conflicts. (San Francisco: Jossey- Bass Publishers, 2001), 211. 2"Coalition Building,” op.cit 4 Joint Center for Operational Analysis and Lessons...Lessons Learned (CALL) 10 Meade Avenue Bldg. 50 Fort Leavenworth, KS 66027 user name phone# COL Larry Saul , Director (Lawrence.saul) x2255 Mr. Larry

  11. FEASIBILITY STUDY REPORT FOR THE 200-ZP-1 GROUNDWATER OPERABLE UNIT

    Energy Technology Data Exchange (ETDEWEB)

    BYRNES ME

    2008-07-18

    The Hanford Site, managed by the U.S. Department of Energy (DOE), encompasses approximately 1,517 km{sup 2} (586 mi{sup 2}) in the Columbia Basin of south-central Washington State. In 1989, the U.S. Environmental Protection Agency (EPA) placed the 100, 200, 300, and 1100 Areas of the Hanford Site on the 40 Code of Federal Regulations (CFR) 300, 'National Oil and Hazardous Substances Pollution Contingency Plan' National Contingency Plan [NCPD], Appendix B, 'National Priorities List' (NPL), pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The 200 Areas NPL sites consist of the 200 West and 200 East Areas (Figure 1-1). The 200 Areas contain waste management facilities, inactive irradiated fuel reprocessing facilities, and the 200 North Area (formerly used for interim storage and staging of irradiated fuel). Several waste sites in the 600 Area, located near the 200 Areas, also are included in the 200 Areas NPL site. The 200 Areas NPL site is in a region referred to as the 'Central Plateau' and consists of approximately 700 waste sites, excluding sites assigned to the tank farm waste management areas (WMAs). The 200-ZP-1 Groundwater Operable Unit (OU) consists of the groundwater located under the northern portion of the 200 West Area. Waste sources that contributed to the 200-ZP-1 OU included cribs and trenches that received liquid and/or solid waste in the past from the Z Plant and T Plant aggregate areas, WMA-T, WMA-TX/TY, and the State-Approved Land Disposal Site (SALDS). This feasibility study (FS) for the 200-ZP-1 Groundwater OU was prepared in accordance with the requirements of CERCLA decision documents. These decision documents are part of the Administrative Record for the selection of remedial actions for each waste site and present the selected remedial actions that are chosen in accordance with CERCLA, as amended by the Superfund Amendments and Reauthorization Act of 1986

  12. FEASIBILITY STUDY REPORT FOR THE 200-ZP-1 GROUNDWATER OPERABLE UNIT

    Energy Technology Data Exchange (ETDEWEB)

    BYRNES ME

    2008-07-18

    The Hanford Site, managed by the U.S. Department of Energy (DOE), encompasses approximately 1,517 km{sup 2} (586 mi{sup 2}) in the Columbia Basin of south-central Washington State. In 1989, the U.S. Environmental Protection Agency (EPA) placed the 100, 200, 300, and 1100 Areas of the Hanford Site on the 40 Code of Federal Regulations (CFR) 300, 'National Oil and Hazardous Substances Pollution Contingency Plan' National Contingency Plan [NCPD], Appendix B, 'National Priorities List' (NPL), pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The 200 Areas NPL sites consist of the 200 West and 200 East Areas (Figure 1-1). The 200 Areas contain waste management facilities, inactive irradiated fuel reprocessing facilities, and the 200 North Area (formerly used for interim storage and staging of irradiated fuel). Several waste sites in the 600 Area, located near the 200 Areas, also are included in the 200 Areas NPL site. The 200 Areas NPL site is in a region referred to as the 'Central Plateau' and consists of approximately 700 waste sites, excluding sites assigned to the tank farm waste management areas (WMAs). The 200-ZP-1 Groundwater Operable Unit (OU) consists of the groundwater located under the northern portion of the 200 West Area. Waste sources that contributed to the 200-ZP-1 OU included cribs and trenches that received liquid and/or solid waste in the past from the Z Plant and T Plant aggregate areas, WMA-T, WMA-TX/TY, and the State-Approved Land Disposal Site (SALDS). This feasibility study (FS) for the 200-ZP-1 Groundwater OU was prepared in accordance with the requirements of CERCLA decision documents. These decision documents are part of the Administrative Record for the selection of remedial actions for each waste site and present the selected remedial actions that are chosen in accordance with CERCLA, as amended by the Superfund Amendments and Reauthorization Act of 1986

  13. Digraph Matrix Analysis for systems interactions at Indian Point Unit 3. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Alesso, H.P.; Altenbach, T.J.; Prassinos, P.G.; Lappa, D.A.; Kimura, C.Y.; Patenaude, C.J.; Sacks, I.J.; Ashmore, B.C.; Fromme, D.C.; Hershberger, M.V.

    1986-01-01

    This report documents the analysis of the Indian Point Plant, Unit 3 (IP-3) for adverse systems interactions using DMA. The primary objective of the study was to compare the effectiveness of DMA in finding systems interactions. To this end a parallel study was funded at Brookhaven National Laboratory (BNL). The results of this study and the BNL study will then be compared by NRC to the results of a similar study performed by the Power Authority of the State of New York. A secondary objective of this study was to determine systems interactions in selected combinations of safety systems at IP-3. 24 refs., 22 figs., 29 tabs.

  14. United States Air Force Summer Faculty Research Program. 1985 Technical Report. Volume 3.

    Science.gov (United States)

    1985-12-01

    Air Force materials with polution potential include jet fuel, deicer, different pesticides and Aqueous Fire Fighting Foam (AFFF). Spills and leakage...L AD-Ai66 178 UNITED STATES AIR FORCE SUMMER FACULTY RESEARCH PROGRAM 1/11 1985 TECHNICAL RE..(U) UNIVERSAL ENERGY SYSTEMS INC DAYTON OH R C DARRAH...EIIIIEEEIIIEEE 36 Ml ROCOPY RESOLUTION TEST CHART NtATIONdAL "URI4 OF SVAOAS - 963 -A j AIR FORCE OFFICE OF SCIENTIFIC RESEAfjCH-- ;’’UNITEP.STATES A11R.-FORG

  15. Day-Ahead Coordination of Vehicle-to-Grid Operation and Wind Power in Security Constraints Unit Commitment (SCUC

    Directory of Open Access Journals (Sweden)

    Mohammad Javad Abdollahi

    2015-08-01

    Full Text Available In this paper security constraints unit commitment (SCUC in the presence of wind power resources and electrical vehicles to grid is presented. SCUC operation prepare an optimal time table for generation unit commitment in order to maximize security, minimize operation cost and satisfy the constraints of networks and units in a period of time, as one of the most important research interest in power systems. Today, the relationship between power network and energy storage systems is interested for many researchers and network operators. Using Electrical Vehicles (PEVs and wind power for energy production is one of the newest proposed methods for replacing fossil fuels.One of the effective strategies for analyzing of the effects of Vehicle 2 Grid (V2G and wind power in optimal operation of generation is running of SCUC for power systems that are equipped with V2G and wind power resources. In this paper, game theory method is employed for deterministic solution of day-ahead unit commitment with considering security constraints in the simultaneous presence of V2G and wind power units. This problem for two scenarios of grid-controlled mode and consumer-controlled mode in three different days with light, medium and heavy load profiles is analyzed. Simulation results show the effectiveness of the presence of V2G and wind power for decreasing of generation cost and improving operation indices of power systems.

  16. Information as Power. An Anthology of Selected United States Army War College Student Papers. Volume 4

    Science.gov (United States)

    2010-01-01

    Tacit Knowledge To From 117Information Effects through Network and Knowleged-based Operations on knowledge previously acquired. Immanuel Kant, Jean Piaget ...and context enables the transfer of knowledge.38 Etienne Wenger and Jean Lave first introduced the term Communities of Practice (CoP) more than 15...unintentional Role of activity, context, and culture Cultural Stage Theory of Cognitive Development Piaget Cognition develops in four stages: sensorimotor

  17. Ideas, Concepts, Doctrine: Basic Thinking in the United States Air Force, 1907-1960. Volume 1

    Science.gov (United States)

    1989-12-01

    nothing to it so far except in an experimental way." 12 Nevertheless, during a period of strained relations with Mexico , Army aviators were ordered to...operations against a hostile force in Mexico . The Air Corps submitted these plans on 13July ; on 11 August a special committee ofthe Army General...determined to haggle , particularly over the length of time that prisoners wouldbe held in custody by a neutral nation’s repatriation commission . On 4June

  18. Weather data for simplified energy calculation methods. Volume I. Eastern United States: TRY data

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, A.R.; Moreno, S.; Deringer, J.; Watson, C.R.

    1984-08-01

    The objective of this report is to provide a source of weather data for direct use with a number of simplified energy calculation methods available today. Complete weather data for a number of cities in the United States are provided for use in the following methods: degree hour, modified degree hour, bin, modified bin, and variable degree day. This report contains sets of weather data for 23 cities in the continental United States using Test Reference Year (TRY) source weather data. The weather data at each city has been summarized in a number of ways to provide differing levels of detail necessary for alternative simplified energy calculation methods. Weather variables summarized include dry bulb and wet bulb temperature, percent relative humidity, humidity ratio, wind speed, percent possible sunshine, percent diffuse solar radiation, total solar radiation on horizontal and vertical surfaces, and solar heat gain through standard DSA glass. Monthly and annual summaries, in some cases by time of day, are available. These summaries are produced in a series of nine computer generated tables.

  19. Weather data for simplified energy calculation methods. Volume II. Middle United States: TRY data

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, A.R.; Moreno, S.; Deringer, J.; Watson, C.R.

    1984-08-01

    The objective of this report is to provide a source of weather data for direct use with a number of simplified energy calculation methods available today. Complete weather data for a number of cities in the United States are provided for use in the following methods: degree hour, modified degree hour, bin, modified bin, and variable degree day. This report contains sets of weather data for 22 cities in the continental United States using Test Reference Year (TRY) source weather data. The weather data at each city has been summarized in a number of ways to provide differing levels of detail necessary for alternative simplified energy calculation methods. Weather variables summarized include dry bulb and wet bulb temperature, percent relative humidity, humidity ratio, wind speed, percent possible sunshine, percent diffuse solar radiation, total solar radiation on horizontal and vertical surfaces, and solar heat gain through standard DSA glass. Monthly and annual summaries, in some cases by time of day, are available. These summaries are produced in a series of nine computer generated tables.

  20. Operation and control of flow manufacturing based on constraints management for high-mix/low-volume production

    Institute of Scientific and Technical Information of China (English)

    Zailin GUAN; Yunfang PENG; Li MA; Chaoyong ZHANG; Peigen LI

    2008-01-01

    The existing technology of flow manufacturing, which is mainly appropriate for high volume and repetitive production, is proven difficult to be applied in high-mix/ low-volume environments. To adapt lean production into the latter, a new type of flow manufacturing is proposed based on flow path management technology. This paper first describes the general operation framework of the pro-posed new mode. The main idea is the dynamic formation of adaptable virtual production lines (called flow paths) corresponding to different product families. The applica-tion of different theories of constraints/drum-buffer-rope (TOC/DBR) control policies depends on the differences in scope of variety and scale of demand for these product families. The overall architecture of the proposed mech-anism of constraint management-based operation and con-trol is introduced. For the implementation, a mathematical programming method is suggested for the dynamic plan-ning of flow paths, and a TOC/DBR 'path-specific' mech-anism with group scheduling is used for the control over each flow path. We also study other critical issues including the identification and management of resource bottlenecks, and the setting of the buffer size in the deployment of the TOC/DBR mechanism.

  1. Commissioning and quality assurances of the Intrabeam Intra-Operative radiotherapy unit

    Directory of Open Access Journals (Sweden)

    KR Muralidhar

    2014-12-01

    Full Text Available Purpose: The authors report comprehensive commissioning and quality assurance (QA procedures for Intrabeam, Intra-Operative radiotherapy (IORT unit. The Intrabeam system miniature X-ray source is a 50 kV and 40 µA unit. Methods: The authors’ tests include measurements of output, beam deflection, isotropy, kVp and mAs measurements, quality index, isodose, reproducibility, linearity, depth dose verification, and 3D dose distribution. IC ionization chamber and the UNIDOSE dosimeter were used for the output commissioning. Probe adjuster/ionization chamber holder (PAICH was used to check the mechanical straightness of the probe. For radiation tests, NACP parallel plate chamber, Standard Imaging electrometer, 30 × 30 × 30 cm3 IAEA water phantom, solid water slabs, EDR-2 Films with RIT software, and ionization based survey meters were used. Unfors Xi platinum edition kVp meter was used to measure the kVp and mAs. Results: In mechanical QA test, X-Beam position (-0.09 mm, Y-Beam position (0.01 mm, and radial position (0.11 mm errors were within the tolerance level. Isotropy test with PDA, survey meter, ion chamber, and film measurements also produced results within the specifications. Output measurements with PAICH and external chamber measurements were matched. Beam quality, linearity, and reproducibility values were ascertained at 50KV and 40 µA and found to be within limits. Isodose, 3D dose distribution, transverse, and horizontal profiles showed the good isotropy of the source. Conclusion: The authors’ methodology provides comprehensive commissioning and calibration procedures for the Intrabeam system.

  2. Journal of Special Operations Medicine. Volume 5, Edition 1, Winter 2005

    Science.gov (United States)

    2005-01-01

    LEP options that will protect our operators while not degrading mission capability. Finally, I believe that our command needs a comprehensive Fatigue...loss from non-occupational cir- cumstances is degrading both real-time combat readi- ness and long-term retention. In the last 18 months an Echelon III...generation fluoroquinolone , gatifloxacin. SOF medics from the 96th CA BN and others students found that the Tactical Combat Casualty Care training emphasizes

  3. SOLLIMS Sampler: Targeting Peace & Stability Operations Lessons & Best Practices. Volume 3, Issue 2

    Science.gov (United States)

    2012-04-01

    Dr. Roshan, a licensed veterinarian who is part of a team directed by the Kunar provincial veterinarian . (U.S. Air Force photo by Captain Peter...the military leadership of a Provincial Reconstruction Team (PRT) located in Panjshir had planned a program to bring American veterinarians to...Table of Contents | Quick Look | Contact PKSOI Page 27 of 42 USNS Comfort, equipped with surgical operating teams and orthopedic

  4. CRONUS, A Distributed Operating System: Volume 1. Revised System/ Subsystem Specification

    Science.gov (United States)

    1988-06-01

    Cronus processes work and how they communicate with each other. In the following discussion, it is usually safe to visualize a Cronus process as being...cronus:printers. under names such as imaqen for an imagen laser printer and fifth floor for a standard impact printer located on the fifth floor...Event reports should be displayed along with either a visual or audible alert to attract the operator’s attention. Event reports should be recorded so

  5. Journal of Special Operations Medicine. Volume 8, Edition 4, Fall 2008

    Science.gov (United States)

    2008-01-01

    Ernesto “Che” Guevara is a name that brings up an image in the mind of millions around the world. From the iconic image on T-shirts of teens who can’t...observations of Gue- vara correspond to current practice in modern Special Operations medicine. Guevara distinguishes three types of medical care in guerilla...The morale boost resulting from having this medic with a guerilla force is also enthusiastically discussed. The second phase Guevara identifies as

  6. Journal of Special Operations Medicine. Volume 10, Edition 2, Spring 2010

    Science.gov (United States)

    2010-01-01

    offensive operations, and mili- tary working dogs . For many years the only POI offered in a schoolhouse environment that teaches aviation medi- cine has...exclusive purview of specific medical specialties such as radiology, cardiology , and obstetrics and gynecology, but today it finds a role across primary care...9 DOWN Web Site: www.k9down.com K-9 Down is a highly specialized program designed for professional working dog handlers and emergency rescue

  7. Joint Center for Operational Analysis Quarterly Bulletin. Volume 8, Issue 2, March 2006

    Science.gov (United States)

    2006-03-01

    released workers and a social safety net that can support the newly unemployed during the transition. In the meantime, restarting industry is a matter of...Commander, introduces us to his command and gives us an overview of their mission of supporting the combatant commands (COCOM) through prototype...contained communications package used to provide direct operational support during a contingency or crisis. Hopefully, these articles and the final JSIC

  8. Microwave power transmission system studies. Volume 3, section 8: Mechanical systems and flight operations

    Science.gov (United States)

    Maynard, O. E.; Brown, W. C.; Edwards, A.; Haley, J. T.; Meltz, G.; Howell, J. M.; Nathan, A.

    1975-01-01

    The efforts and recommendations associated with preliminary design and concept definition for mechanical systems and flight operations are presented. Technical discussion in the areas of mission analysis, antenna structural concept, configuration analysis, assembly and packaging with associated costs are presented. Technology issues for the control system, structural system, thermal system and assembly including cost and man's role in assembly and maintenance are identified. Background and desired outputs for future efforts are discussed.

  9. United States Air Force Summer Research Program -- 1993. Volume 2. Armstrong Laboratory

    Science.gov (United States)

    1993-12-01

    1985) AppI . Environ. Microbiol., 50: 1058-1063. 5. Dwyer, D. F., M. L. Krumme, S. A. Boyd and J. M. Tiedje, (1986) Appl. Environ. Microbiol. , 52: 345...fan. Shuttling action was performed using a hydraulic test machine operated at a frequency of 1.67x10-3 Hz (10 min/cycle) in a stroke -controlled mode...been reported to result in a significantly higher incidence of preterm delivery, perinatal death and fetal growth retardation (13-15). The above

  10. Critical evaluation of the nonradiological environmental technical specifications. Volume 3. Peach Bottom Atomic Power Station Units 2 and 3

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S.M.; Cunningham, P.A.; Gray, D.D.; Kumar, K.D.; Witten, A.J.

    1976-08-10

    A comprehensive study of the data collected as part of the environmental Technical Specifications program for Units 2 and 3 of the Peach Bottom Nuclear Power Plant was conducted for the Office of Regulatory Research of the U.S. Nuclear Regulatory Commission. The program included an analysis of both the hydrothermal and ecological monitoring data collected from 1967 through 1976. Specific recommendations are made for improving both the present hydrothermal and ecological monitoring programs. Hydrothermal monitoring would be improved by more complete reporting of in-plant operating parameters. In addition, the present boat surveys could be discontinued, and monitoring efforts could be directed toward expanding the present thermograph network. Ecological monitoring programs were judged to be of high quality because standardized collection techniques, consistent reporting formats, and statistical analyses were performed on all of the data and were presented in an annual report. Sampling for all trophic groups was adequate for the purposes of assessing power plant induced perturbations. Considering the extensive period of preoperational data (six years) and operational data (three years) available for analysis, consideration could be given to reducing monitoring effort after data have been collected for a period when both units are operating at full capacity. In this way, an assessment of the potential ecological impact of the Peach Bottom facility can be made under conditions of maximum plant induced perturbations.

  11. Very prolonged stay in the intensive care unit after cardiac operations: early results and late survival.

    Science.gov (United States)

    Silberman, Shuli; Bitran, Daniel; Fink, Daniel; Tauber, Rachel; Merin, Ofer

    2013-07-01

    Prolonged intensive care unit (ICU) stay is a surrogate for advanced morbidity or perioperative complications, and resource utilization may become an issue. It is our policy to continue full life support in the ICU, even for patients with a seemingly grim outlook. We examined the effect of duration of ICU stay on early outcomes and late survival. Between 1993 and 2011, 6,385 patients were admitted to the ICU after cardiac surgery. Patients were grouped according to length of stay in the ICU: group 1, 2 days or less (n = 4,631; 73%); group 2, 3 to 14 days (n = 1,423; 22%); group 3, more than 14 days (n = 331; 5%). Length of stay in ICU for group 3 patients was 38 ± 24 days (range, 15 to 160; median 31). Clinical profile and outcomes were compared between groups. Patients requiring prolonged ICU stay were older, underwent more complex surgery, had greater comorbidity, and a higher predicted operative mortality (p < 0.0001). They had a higher incidence of adverse events and increased mortality (p < 0.0001). Of the 331 group 3 patients, 60% were discharged: survival of these patients at 1, 3, and 5 years was 78%, 65%, and 52%, respectively. Operative mortality as well as late survival of discharged patients was proportional to duration of ICU stay. Current technology enables keeping sick patients alive for extended periods of time. Nearly two thirds of patients requiring prolonged ICU leave hospital, and of these, 50% attain 5-year survival. These data support offering full and continued support even for patients requiring very prolonged ICU stay. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. GROUDWATER REMEDIATION AT THE 100-HR-3 OPERABLE UNIT HANFORD SITE WASHINGTON USA - 11507

    Energy Technology Data Exchange (ETDEWEB)

    SMOOT JL; BIEBESHEIMER FH; ELUSKIE JA; SPILIOTOPOULOS A; TONKIN MJ; SIMPKIN T

    2011-01-12

    The 100-HR-3 Groundwater Operable Unit (OU) at the Hanford Site underlies three former plutonium production reactors and the associated infrastructure at the 100-D and 100-H Areas. The primary contaminant of concern at the site is hexavalent chromium; the secondary contaminants are strontium-90, technetium-99, tritium, uranium, and nitrate. The hexavalent chromium plume is the largest plume of its type in the state of Washington, covering an area of approximately 7 km{sup 2} (2.7 mi{sup 2}) with concentrations greater than 20 {micro}g/L. Concentrations range from 60,000 {micro}g/L near the former dichromate transfer station in the 100-D Area to large areas of 20 to 100 {micro}g/L across much of the plume area. Pump-and-treat operations began in 1997 and continued into 2010 at a limited scale of approximately 200 gal/min. Remediation of groundwater has been fairly successful in reaching remedial action objectives (RAOs) of 20 {micro}g/L over a limited region at the 100-H, but less effective at 100-D. In 2000, an in situ, permeable reactive barrier was installed downgradient of the hotspot in 100-D as a second remedy. The RAOs are still being exceeded over a large portion of the area. The CH2M HILL Plateau Remediation Company was awarded the remediation contract for groundwater in 2008 and initiated a remedial process optimization study consisting of modeling and technical studies intended to enhance the remediation. As a result of the study, 1,400 gal/min of expanded treatment capacity are being implemented. These new systems are designed to meet 2012 and 2020 target milestones for protection of the Columbia River and cleanup of the groundwater plumes.

  13. Operating room fire prevention: creating an electrosurgical unit fire safety device.

    Science.gov (United States)

    Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J

    2014-08-01

    To reduce the incidence of surgical fires. Operating room fires represent a potentially life-threatening hazard and are triggered by the electrosurgical unit (ESU) pencil. Carbon dioxide is a fire suppressant and is a routinely used medical gas. We hypothesize that a shroud of protective carbon dioxide covering the tip of the ESU pencil displaces oxygen, thereby preventing fire ignition. Using 3-dimensional modeling techniques, a polymer sleeve was created and attached to an ESU pencil. This sleeve was connected to a carbon dioxide source and directed the gas through multiple precisely angled ports, generating a cone of fire-suppressive carbon dioxide surrounding the active pencil tip. This device was evaluated in a flammability test chamber containing 21%, 50%, and 100% oxygen with sustained ESU activation. The sleeve was tested with and without carbon dioxide (control) until a fuel was ignited or 30 seconds elapsed. Time to ignition was measured by high-speed videography. Fires were ignited with each control trial (15/15 trials). The control group median ± SD ignition time in 21% oxygen was 3.0 ± 2.4 seconds, in 50% oxygen was 0.1 ± 1.8 seconds, and in 100% oxygen was 0.03 ± 0.1 seconds. No fire was observed when the fire safety device was used in all concentrations of oxygen (0/15 trials; P fire ignition was 76% to 100%. A sleeve creating a cone of protective carbon dioxide gas enshrouding the sparks from an ESU pencil effectively prevents fire in a high-flammability model. Clinical application of this device may reduce the incidence of operating room fires.

  14. 5-year operation experience with the 1.8 K refrigeration units of the LHC cryogenic system

    CERN Document Server

    Ferlin, G; Claudet, S; Pezzetti, M

    2015-01-01

    Since 2009, the Large Hadron Collider (LHC) is in operation at CERN. The LHC superconducting magnets distributed over eight sectors of 3.3-km long are cooled at 1.9 K in pressurized superfluid helium. The nominal operating temperature of 1.9 K is produced by eight 1.8-K refrigeration units based on centrifugal cold compressors (3 or 4 stages depending to the vendor) combined with warm volumetric screw compressors with sub-atmospheric suction. After about 5 years of continuous operation, we will present the results concerning the availability for the final user of these refrigeration units and the impact of the design choice on the recovery time after a system trip. We will also present the individual results for each rotating machinery in terms of failure origin and of Mean Time between Failure (MTBF), as well as the consolidations and upgrades applied to these refrigeration units.

  15. Operation of the counter-rotating type pump-turbine unit installed in the power stabilizing system

    Science.gov (United States)

    Kanemoto, T.; Honda, H.; Kasahara, R.; Miyaji, T.

    2014-03-01

    This serial research intends to put a unique power stabilization system with a pumped storage into practical use. The pumped storage is equipped with a counter-rotating type pump-turbine unit whose operating mode can be shifted instantaneously in response to the fluctuation of power from renewable resources. This paper verifies that the system is reasonably effective to stabilize the fluctuating power. It is necessary to quickly increase the rotational speed when the operation is shifted from the turbine to the pumping modes, because the unit cannot pump-up water from a lower reservoir at a slow rotational speed while keeping gross/geodetic head constant. The maximum hydraulic efficiency at the turbine mode is close to the efficiency of the counter-rotating type hydroelectric unit designed exclusively for the turbine mode. The system is also provided for a pilot plant to be operated in the field.

  16. Proceedings of Military Operations Research Symposia (Index) Volume 3. 31st through 40th inclusive

    Science.gov (United States)

    1980-11-01

    aid- ing in tactical operations, 38-280 Erler Robert J! (with GD talushynsky and llV Wilson), Point defense requirements model: methodology and Frieder...CONUS eir defense. 34-34 pote Address. 33rd MiORS). 3f3-3 lialushynsky George D (with RII Erler and IJY Wilson). loltrv A (with C Andersen and R...301 40-188 i °A Washburn Allen R, Some thoughts on the changing Wilson Harold V (with RH Erler and ui Halushynsky), environment for cost-effectiveness

  17. Compilation of Energy Efficient Concepts in Advanced Aircraft Design and Operations. Volume 2. Abstract Data Base

    Science.gov (United States)

    1980-11-05

    60 B.2 PROPULSION TECNOLOGY B-2.1 GAS TURBINES B.2.1.i NAVY FUNDED I B2-1I NADC-79239-60 B.2.1.1.l SSIE: CQN 975316 3/79 to Cont Colorado State...which are also beter for fuel and operating cost economy) push the desired bypass ratio up further. Effects on fuel consumption of design field...design features include high-aspect-ratio wings, thickness ratio and range. It is conclu&d that wing aspect ratios of future aircraft are I - push of

  18. ADST Operation Manual for the Management Command and Control. Volume 2. SIMNET/MASSCOMP Host MCC

    Science.gov (United States)

    1993-03-31

    Simulator: 9A A Company A Helicopter Type @ Attack 0 Defense 0 Scout 0 Offense Dumper No. Li)I Obseruer Location Azimuth (Mils) Fuel Load 12444 (Lbs...new mission or monitor on-going missions with the use of messages and requests for information. Before a mission can be completed, several steps must...mission and to return to Figure 9-1. Click on the No changes button to cancel the changes. Page 164 SIMNET Operations Manual March 31, 1993 9.4 Monitoring

  19. UWB EMI To Aircraft Radios: Field Evaluation on Operational Commercial Transport Airplanes. Volume 1

    Science.gov (United States)

    Oria, A. J. (Editor); Ely, Jay J.; Martin, Warren L.; Shaver, Timothy W.; Fuller, Gerald L.; Zimmerman, John; Fuschino, Robert L.; Larsen, William E.

    2005-01-01

    Ultrawideband (UWB) transmitters may soon be integrated into a wide variety of portable electronic devices (PEDs) that passengers routinely carry on board commercial airplanes. Airlines and the FAA will have difficulty controlling passenger use of UWB transmitters during flights with current airline policies and existing wireless product standards. The aeronautical community is concerned as to whether evolving FCC UWB rules are adequate to protect legacy and emerging aeronautical radio systems from electromagnetic interference (EMI) from emerging UWB products. To address these concerns, the NASA Office of Space Communications and Chief Spectrum Managers assembled a multidisciplinary team from NASA LaRC, NASA JPL, NASA ARC, FAA, United Airlines, Sky West Airlines, and Eagles Wings Inc. to carry out a comprehensive series of tests aimed at determining the nature and extent of any EMI to aeronautical communication and navigation systems from UWB devices meeting FCCapproved and proposed levels for unlicensed handheld transmitters.

  20. Data validation report for the 100-FR-3 Operable Unit, third round groundwater samples

    Energy Technology Data Exchange (ETDEWEB)

    Ayres, J.M.

    1994-03-31

    Westinghouse-Hanford has requested that a minimum of 20% of the total number of Sample Delivery Groups be validated for the 100-FR-3 operable Unit Third Round Groundwater sampling investigation. Therefore, the data from the chemical analysis of 51 samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site. The report is broken down into sections for each chemical analysis and radiochemical analysis type. Each section addresses the data package completeness, holding time adherence, instrument calibration and tuning acceptability, blank results, accuracy, precision, system performance, as well as the compound identification and quantitation. In addition, each section has an overall assessment and summary for the data packages reviewed for the particular chemical/radiochemical analyses. Detailed backup information is provided to the reader by SDG No. and sample number. For each data package, a matrix of chemical analyses per sample number is presented, as well as data qualification summaries.

  1. jMOTU and Taxonerator: turning DNA Barcode sequences into annotated operational taxonomic units.

    Directory of Open Access Journals (Sweden)

    Martin Jones

    Full Text Available BACKGROUND: DNA barcoding and other DNA sequence-based techniques for investigating and estimating biodiversity require explicit methods for associating individual sequences with taxa, as it is at the taxon level that biodiversity is assessed. For many projects, the bioinformatic analyses required pose problems for laboratories whose prime expertise is not in bioinformatics. User-friendly tools are required for both clustering sequences into molecular operational taxonomic units (MOTU and for associating these MOTU with known organismal taxonomies. RESULTS: Here we present jMOTU, a Java program for the analysis of DNA barcode datasets that uses an explicit, determinate algorithm to define MOTU. We demonstrate its usefulness for both individual specimen-based Sanger sequencing surveys and bulk-environment metagenetic surveys using long-read next-generation sequencing data. jMOTU is driven through a graphical user interface, and can analyse tens of thousands of sequences in a short time on a desktop computer. A companion program, Taxonerator, that adds traditional taxonomic annotation to MOTU, is also presented. Clustering and taxonomic annotation data are stored in a relational database, and are thus amenable to subsequent data mining and web presentation. CONCLUSIONS: jMOTU efficiently and robustly identifies the molecular taxa present in survey datasets, and Taxonerator decorates the MOTU with putative identifications. jMOTU and Taxonerator are freely available from http://www.nematodes.org/.

  2. An operational evaluation of the Community Oral Rehydration Units in Peru.

    Science.gov (United States)

    Benavides, B M; Jacoby, E R

    1994-12-01

    Since 1984, in Latin America donor agencies and national governments have extensively supported the implementation of the Community Oral Rehydration Units (CORUs) in an attempt to increase the access to oral rehydration therapy and improve the case management of diarrhoea at the community level. This study surveyed 40 CORUs in two regions of Peru to assess their operation, the number of patients with diarrhoea attended, and the knowledge of volunteers in charge. The results show that CORUs were mainly implemented close to existing health centres; the median of case load was 2.0 patients in the preceding month; and the volunteers' knowledge of case management was principally deficient in the diagnosis of hydration status, dietary management and in preventive measures. This lack of knowledge was replicated by professionals at the supervising health centres. Despite the fact that CORUs have been functioning for around four years, they exhibit numerous deficiencies which prevent them from fulfilling their objectives. A global review of the whole CORU strategy is called for.

  3. Qualitative research within trials: developing a standard operating procedure for a clinical trials unit

    Science.gov (United States)

    2013-01-01

    Background Qualitative research methods are increasingly used within clinical trials to address broader research questions than can be addressed by quantitative methods alone. These methods enable health professionals, service users, and other stakeholders to contribute their views and experiences to evaluation of healthcare treatments, interventions, or policies, and influence the design of trials. Qualitative data often contribute information that is better able to reform policy or influence design. Methods Health services researchers, including trialists, clinicians, and qualitative researchers, worked collaboratively to develop a comprehensive portfolio of standard operating procedures (SOPs) for the West Wales Organisation for Rigorous Trials in Health (WWORTH), a clinical trials unit (CTU) at Swansea University, which has recently achieved registration with the UK Clinical Research Collaboration (UKCRC). Although the UKCRC requires a total of 25 SOPs from registered CTUs, WWORTH chose to add an additional qualitative-methods SOP (QM-SOP). Results The qualitative methods SOP (QM-SOP) defines good practice in designing and implementing qualitative components of trials, while allowing flexibility of approach and method. Its basic principles are that: qualitative researchers should be contributors from the start of trials with qualitative potential; the qualitative component should have clear aims; and the main study publication should report on the qualitative component. Conclusions We recommend that CTUs consider developing a QM-SOP to enhance the conduct of quantitative trials by adding qualitative data and analysis. We judge that this improves the value of quantitative trials, and contributes to the future development of multi-method trials. PMID:23433341

  4. ALTERNATIVE REMEDIATION TECHNOLOGY STUDY FOR GROUNDWATER TREATMENT AT 200-PO-1 OPERABLE UNIT AT HANFORD SITE

    Energy Technology Data Exchange (ETDEWEB)

    DADO MA

    2008-07-31

    This study focuses on the remediation methods and technologies applicable for use at 200-PO-I Groundwater Operable Unit (OU) at the Hanford Site. The 200-PO-I Groundwater au requires groundwater remediation because of the existence of contaminants of potential concern (COPC). A screening was conducted on alternative technologies and methods of remediation to determine which show the most potential for remediation of groundwater contaminants. The possible technologies were screened to determine which would be suggested for further study and which were not applicable for groundwater remediation. COPCs determined by the Hanford Site groundwater monitoring were grouped into categories based on properties linking them by remediation methods applicable to each COPC group. The screening considered the following criteria. (1) Determine if the suggested method or technology can be used for the specific contaminants found in groundwater and if the technology can be applied at the 200-PO-I Groundwater au, based on physical characteristics such as geology and depth to groundwater. (2) Evaluate screened technologies based on testing and development stages, effectiveness, implementability, cost, and time. This report documents the results of an intern research project conducted by Mathew Dado for Central Plateau Remediation in the Soil and Groundwater Remediation Project. The study was conducted under the technical supervision of Gloria Cummins and management supervision of Theresa Bergman and Becky Austin.

  5. First Operational Experience with the LHC Beam Dump Trigger Synchronisation Unit

    CERN Document Server

    Antoine, A; Magnin, N; Juteau, P; Voumard, N

    2011-01-01

    Two LHC Beam Dumping Systems (LBDS) remove the counter-rotating beams safely from the collider during setting up of the accelerator, at the end of a physics run and in case of emergencies. Dump requests can come from 3 different sources: the machine protection system in emergency cases, the machine timing system for scheduled dumps or the LBDS itself in case of internal failures. These dump requests are synchronized with the 3 μs beam abort gap in a fail-safe redundant Trigger Synchronization Unit (TSU) based on a Digital Phase Locked Loop (DPLL), locked onto the LHC beam revolution frequency with a maximum phase error of 40 ns. The synchronized trigger pulses coming out of the TSU are then distributed to the high voltage generators of the beam dump kickers through a redundant fault-tolerant trigger distribution system. This paper describes the operational experience gained with the TSU since its commissioning with beam in 2009, and highlights the improvements, which have been implemented f...

  6. Weather data for simplified energy calculation methods. Volume IV. United States: WYEC data

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, A.R.; Moreno, S.; Deringer, J.; Watson, C.R.

    1984-08-01

    The objective of this report is to provide a source of weather data for direct use with a number of simplified energy calculation methods available today. Complete weather data for a number of cities in the United States are provided for use in the following methods: degree hour, modified degree hour, bin, modified bin, and variable degree day. This report contains sets of weather data for 23 cities using Weather Year for Energy Calculations (WYEC) source weather data. Considerable overlap is present in cities (21) covered by both the TRY and WYEC data. The weather data at each city has been summarized in a number of ways to provide differing levels of detail necessary for alternative simplified energy calculation methods. Weather variables summarized include dry bulb and wet bulb temperature, percent relative humidity, humidity ratio, wind speed, percent possible sunshine, percent diffuse solar radiation, total solar radiation on horizontal and vertical surfaces, and solar heat gain through standard DSA glass. Monthly and annual summaries, in some cases by time of day, are available. These summaries are produced in a series of nine computer generated tables.

  7. Engineering aspects and hardware verification of a volume producable solid oxide fuel cell stack design for diesel auxiliary power units

    Science.gov (United States)

    Stelter, Michael; Reinert, Andreas; Mai, Björn Erik; Kuznecov, Mihail

    A solid oxide fuel cell (SOFC) stack module is presented that is designed for operation on diesel reformate in an auxiliary power unit (APU). The stack was designed using a top-down approach, based on a specification of an APU system that is installed on board of vehicles. The stack design is planar, modular and scalable with stamped sheet metal interconnectors. It features thin membrane electrode assemblies (MEAs), such as electrolyte supported cells (ESC) and operates at elevated temperatures around 800 °C. The stack has a low pressure drop in both the anode and the cathode to facilitate a simple system layout. An overview of the technical targets met so far is given. A stack power density of 0.2 kW l -1 has been demonstrated in a fully integrated, thermally self-sustaining APU prototype running with diesel and without an external water supply.

  8. Volume Entropy

    CERN Document Server

    Astuti, Valerio; Rovelli, Carlo

    2016-01-01

    Building on a technical result by Brunnemann and Rideout on the spectrum of the Volume operator in Loop Quantum Gravity, we show that the dimension of the space of the quadrivalent states --with finite-volume individual nodes-- describing a region with total volume smaller than $V$, has \\emph{finite} dimension, bounded by $V \\log V$. This allows us to introduce the notion of "volume entropy": the von Neumann entropy associated to the measurement of volume.

  9. Micro-cogeneration units based on Stirling engine for heating and their real operation

    Science.gov (United States)

    Čierny, Jaroslav; Patsch, Marek

    2014-08-01

    This article was deal with micro-cogeneration units based on Stirling engine. We watched problematic of real working Stirling engine. The article also contain hookup of unit constructed at University of Zilina.

  10. US Department of Energy Nevada Operations Office annual site environmental report, 1992. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Black, S.C.; Latham, A.R.; Townsend, Y.E. [eds.

    1993-09-01

    This report contains the environmental monitoring and assessment results for the Nevada Test Site for 1992. Monitoring and surveillance on and around the NTS by DOE contractors and Site user organizations during 1992 indicated that underground nuclear testing operations were conducted in compliance with regulations, i.e., the dose the maximally exposed offsite individual could have received was less than 0.15 percent of the guideline for air exposure. All 1992 nuclear events took place during the first three quarters of the calendar year prior to the Congressional testing moratorium. All discharges of radioactive liquids remained onsite in containment ponds, and there was no indication of potential migration of radioactivity to the offsite area through groundwater. Surveillance around the NTS indicated that airborne radioactivity from test operations was not detectable offsite, and no measurable net exposure to members of the offsite population was detected through the offsite dosimetry program. Using the CAP88-PC model and NTS radionuclide emissions data, the calculated maximum effective dose equivalent offsite would have been 0.012 mrem. Any person receiving this dose was also exposed to 78 mrem from natural background radiation. There were no nonradiological releases to the offsite area. Hazardous wastes were shipped to EPA-approved disposal facilities. Compliance with the various regulations stemming from the National Environmental Policy Act is being achieved and, where mandated, permits for air and water discharges and waste management have been obtained from the appropriate agencies. Non-NTS support facilities complied with the requirements of air quality permits and state or local wastewater discharge and hazardous waste permits.

  11. Capital and operating cost estimates. Volume I. Preliminary design and assessment of a 12,500 BPD coal-to-methanol-to-gasoline plant. [Grace C-M-G Plant, Henderson County, Kentucky

    Energy Technology Data Exchange (ETDEWEB)

    1982-08-01

    This Deliverable No. 18b - Capital and Operating Cost Estimates includes a detailed presentation of the 12,500 BPD coal-to-methanol-to-gasoline plant from the standpoint of capital, preoperations, start-up and operations cost estimation. The base capital cost estimate in June 1982 dollars was prepared by the Ralph M. Parsons Company under the direction of Grace. The escalated capital cost estimate as well as separate estimates for preoperations, startup and operations activities were developed by Grace. The deliverable consists of four volumes. Volume I contains details of methodology used in developing the capital cost estimate, summary information on a base June 1982 capital cost, details of the escalated capital cost estimate and separate sections devoted to preoperations, start-up, and operations cost. The base estimate is supported by detailed information in Volumes II, III and IV. The degree of detail for some units was constrained due to proprietary data. Attempts have been made to exhibit the estimating methodology by including data on individual equipment pricing. Proprietary details are available for inspection upon execution of nondisclosure and/or secrecy agreements with the licensors to whom the data is proprietary. Details of factoring certain pieces of equipment and/or entire modules or units from the 50,000 BPD capital estimate are also included. In the case of the escalated capital estimate, Grace has chosen to include a sensitivity analysis which allows for ready assessment of impacts of escalation rates (inflation), contingency allowances and the construction interest financing rates on the escalated capital cost. Each of the estimates associated with bringing the plant to commercial production rates has as a basis the schedule and engineering documentation found in Deliverable No. 14b - Process Engineering and Mechanical Design Report, No. 28b - Staffing Plans, No. 31b - Construction Plan, and No. 33b - Startup and Operation Plan.

  12. Intermediate photovoltaic system application experiment operational performance report. Volume 5 for Lovington Square Shopping Center, Lovington, NM

    Energy Technology Data Exchange (ETDEWEB)

    1981-12-01

    For the months of September and October, 1981, operational performance data are presented for a photovoltaic power system at a New Mexico shopping center. The electrical energy yield, incident solar energy, and efficiency of the solar cell array are given, including daily and monthly energy yield and insolation and efficiency, and energy yield as a function of power level, voltage, cell temperature, and hour of the day. Data are presented for two power conditioning units, including power conditioner input, output, and efficiency. The total photovoltaic system efficiency and capacity factor are given as well as daily availability data. Meteorological data include monthly insolation data, heating and cooling degree days, average monthly ambient temperature, monthly average wind speed and distribution of wind directions. Also included are plots of cell temperature, ambient temperature, wind speed, and insolation versus the hour of the day. Also included is a brief narrative description of the system operation and data. (LEW)

  13. Office for Analysis and Evaluation of Operational Data 1992 annual report: Power reactors. Volume 7, No. 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    1993-07-01

    The annual report of the US Nuclear Regulatory Commission`s Office for Analysis and Evaluation of Operational Data (AEOD) is devoted to the activities performed during 1992. The report is published in two separate parts. NUREG-1272, Vol. 7, No. 1, covers power reactors and presents an overview of the operating experience of the nuclear power industry from the NRC perspective, including comments about the trends of some key performance, measures. The report also includes the principal findings and issues identified in AEOD studies over the past year, and summarizes information from such sources as licensee event report% diagnostic evaluations, and reports to the NRC`s Operations Center. The reports contain a discussion of the Incident Investigation Team program and summarize the Incident Investigation Team and Augmented Inspection Team reports for that group of licensees. NUREG-1272, Vol. 7, No. 2, covers nonreactors and presents a review of the events and concerns during 1992 associated with the use of licensed material in nonreactor applications, such as personnel overexposures and medical misadministrations. Each volume contains a list of the AEOD reports issued for 1984--1992.

  14. Office for Analysis and Evaluation of Operational Data 1994-FY 95 annual report. Volume 9, Number 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    This annual report of the US Nuclear Regulatory Commission`s Office for Analysis and Evaluation of Operational Data (AEOD) describes activities conducted during CY 1994 and FY 1995. The report is published in three parts. NUREG-1272, Vol. 9, No. 1, covers power reactors and presents an overview of the operating experience of the nuclear power industry from the NRC perspective, including comments about the trends of some key performance measures. The report also includes the principal findings and issues identified in AEOD studies over the past year and summarizes information from such sources as licensee event reports, diagnostic evaluations, and reports to the NRC`s Operations Center. NUREG-1272, Vol. 9, No. 2, covers nuclear materials and presents a review of the events and concerns associated with the use of licensed material in nonreactor applications, such as personnel overexposures and medical misadministrations. Both reports also contain a discussion of the Incident Investigation Team program and summarize both the Incident Investigation Team and Augmented Inspection Team reports. Each volume contains a list of the AEOD reports issued from 1980 through FY 1995. NUREG-1272, Vol. 9, No. 3, covers technical training and presents the activities of the Technical Training Center in support of the NRC`s mission.

  15. Evolution of laparoscopic surgery in a high volume hepatobiliary unit: 150 consecutive pure laparoscopic hepatectomies.

    Science.gov (United States)

    López-Ben, Santiago; Ranea, Alejandro; Albiol, M Teresa; Falgueras, Laia; Castro, Ernesto; Casellas, Margarida; Codina-Barreras, Antoni; Figueras, Joan

    2017-05-01

    Compared to other surgical areas, laparoscopic liver resection (LLR) has not been widely implemented and currently less than 20% of hepatectomies are performed laparoscopically worldwide. The aim of our study was to evaluate the feasibility, and the ratio of implementation of LLR in our department. We analyzed a prospectively maintained database of 749 liver resections performed during the last 10-year period in a single centre. A total of 150 (20%) consecutive pure LLR were performed between 2005 and 2015. In 87% of patients the indication was the presence ofprimary or metastatic liver malignancy. We performed 30 major hepatectomies (20%) and (80%) were minor resections, performed in all liver segments. Twelve patients were operated twice and 2 patients underwent a third LLR. The proportion of LLR increased from 12% in 2011 to 62% in the last year. Conversion rate was 9%. Overall morbidity rate was 36% but only one third were classified as severe. The 90-day mortality rate was 1%. Median hospital stay was 4 days and the rate of readmissions was 6%. The implementation of LLR has been fast with morbidity and mortality comparable to other published series. In the last 2 years more than half of the hepatectomies are performed laparoscopically in our centre. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Continuation of research into software for space operations support, volume 1

    Science.gov (United States)

    Collier, Mark D.; Killough, Ronnie; Martin, Nancy L.

    1990-01-01

    A prototype workstation executive called the Hardware Independent Software Development Environment (HISDE) was developed. Software technologies relevant to workstation executives were researched and evaluated and HISDE was used as a test bed for prototyping efforts. New X Windows software concepts and technology were introduced into workstation executives and related applications. The four research efforts performed included: (1) Research into the usability and efficiency of Motif (an X Windows based graphic user interface) which consisted of converting the existing Athena widget based HISDE user interface to Motif demonstrating the usability of Motif and providing insight into the level of effort required to translate an application from widget to another; (2) Prototype a real time data display widget which consisted of research methods for and prototyping the selected method of displaying textual values in an efficient manner; (3) X Windows performance evaluation which consisted of a series of performance measurements which demonstrated the ability of low level X Windows to display textural information; (4) Convert the Display Manager to X Window/Motif which is the application used by NASA for data display during operational mode.

  17. Approximation of the Laplace and Stokes operators with Dirichlet boundary conditions through volume penalization: a spectral viewpoint

    CERN Document Server

    van yen, Romain Nguyen; Schneider, Kai

    2012-01-01

    We report the results of a detailed study of the spectral properties of Laplace and Stokes operators, modified with a volume penalization term designed to approximate Dirichlet conditions in the limit when a penalization parameter, $\\eta$, tends to zero. The eigenvalues and eigenfunctions are determined either analytically or numerically as functions of $\\eta$, both in the continuous case and after applying Fourier or finite difference discretization schemes. For fixed $\\eta$, we find that only the part of the spectrum corresponding to eigenvalues $\\lambda \\lesssim \\eta^{-1}$ approaches Dirichlet boundary conditions, while the remainder of the spectrum is made of uncontrolled, spurious wall modes. The penalization error for the controlled eigenfunctions is estimated as a function of $\\eta$ and $\\lambda$. Surprisingly, in the Stokes case, we show that the eigenfunctions approximately satisfy, with a precision $O(\\eta)$, Navier slip boundary conditions with slip length equal to $\\sqrt{\\eta}$. Moreover, for a gi...

  18. Field tests of fabric filters on full-scale coal-fired utility boilers. Volume 1. Martin Drake Unit 6, Ray D. Nixon Unit 1, Cherokee Unit 3, Cameo Unit 2, and Arapahoe Unit 3

    Energy Technology Data Exchange (ETDEWEB)

    Felix, L.G.; Cushing, K.M.; Merritt, R.L.; Smith, W.B.

    1985-10-01

    This report discusses the results of a field investigation of full-scale baghouses collecting fly ash at five coal-fired power plants. All five plants burned western, low-sulfur, subbituminous coal and were equipped with baghouses cleaned by reverse gas. Since all of the baghouses operated with clear stacks, particulate collection efficiencies were not measured. Instead, attention was focused on parameters associated with pressure drop, which is important because it is directly related to operating and capital costs. Cleaning-cycle information was taken at the baghouses, and measurements were made of air-to-cloth ratio and tube sheet pressure drop. In addition, seasoned bags and bag samples cut from seasoned bags were weighed to determie dustcake areal loading. Average drag (presure drop/air-to-cloth ratio) and drag measured using these bag samples were recorded. Also, data on the chemical analysis of the coals and their resultant fly ash were gathered, and particle size distribution measurements were made on fly ash samples. Electrical resistivity was measured on fly ash from three locations. 8 refs., 33 figs., 38 tabs.

  19. Methods to model particulate matter clarification of unit operations subject to unsteady loadings.

    Science.gov (United States)

    Spelman, David; Sansalone, John J

    2017-05-15

    Stormwater, and also wastewater unit operations (UOs) to a much lower extent, are subject to unsteady hydrodynamic and particulate matter (PM) fluxes. Simulating fully transient clarification of hetero-disperse PM requires much greater computational expense compared to steady simulations. An alternative to fully unsteady methods are stepwise steady (SS) methods which use stepwise steady flow transport and fate to approximate unsteady PM clarification of a UO during transient hydraulic loadings such as rainfall-runoff. The rationale is reduced computational effort for computational fluid dynamics (CFD) compared to simulating continuous unsteadiness of such events. An implicit solution stepwise steady (IS(3)) method is one approach which builds upon previous SS methods. The IS(3) method computes steady flows that are representative of unsteady PM transport throughout an unsteady loading. This method departs from some previous SS methods that assume PM fate can be simulated with an instantaneous clarifier (basin) influent flowrate coupled with a PM input. In this study, various SS methods were tested for basins of varying size and residence time to examine PM fate. Differences between SS methods were a function of turnover fraction indicating the role of unsteady flowrates on PM transport for larger basins of longer residence times. The breakpoint turnover fraction was between two and three. The IS(3) method best approximated unsteady behavior of larger basins. These methods identified limitations when utilizing standard event-based loading analysis for larger basins. For basins with a turnover fraction less than two, the majority of effluent PM did not originate from the event-based flow; originating from previous event loadings or existing storage. Inter- and multiple event processes and interactions, that are dependent on this inflow turnover fraction, are not accounted for by single event-based inflow models. Results suggest the use of long-term continuous

  20. Phase 1 and 2 feasibility study report for the 300-FF-1 Operable Unit

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    The 300-FF-1 Operable Unit (OU) feasibility study (FS) presented in this document completes the FS process only through the first two study phases: Phase I, Remedial Alternatives Development, and Phase II, Remedial Alternatives Screening in accordance with CERCIA guidance for performing Remedial Investigations and Feasibility Studies (RI/FS) (EPA 1988a). This Phase I/II study provides a generalized view of workable remedial technologies as applied to the site contamination problems as a whole. Phase III, Detailed Analysis of Alternatives, will be performed at a later date to further evaluate screened alternatives based on the nine criteria in the CERCLA RI/FS guidance. The purpose of this Phase I/II FS is to develop and screen a range of alternatives for remediation of contamination present in the vadose zone of the 300-FF-1 OU. The scope of work for this Phase I/II FS includes five primary tasks: 1. Review existing documents and their associated data from relevant investigations and studies; 2. Establish remedial action objectives (RAO) and general response actions (GRA); 3. Identify applicable or relevant and appropriate requirements (ARARS) pertinent to all general response actions (including waste disposal); 4. Develop remedial alternatives (Phase I) applicable to the 300-FF-1 OU including identification and screening of technologies and process options, and assembly of remedial alternatives from representative technology types; 5. Screen alternatives (Phase II) developed in Phase I for implementability, effectiveness, and cost to identify those alternatives which warrant advancement to the detailed analysis phase (Phase III) of the FS.

  1. Fiscal Year 2009 Annual Report for Operable Unit 3-14, Tank Farm Soil and INTEC Groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Forsythe, Howard S.

    2010-04-10

    This annual report summarizes maintenance, monitoring, and inspection activities performed to implement the selected remedy for Waste Area Group 3, Operable Unit 3-14, Tank Farm soil and groundwater at the Idaho Nuclear Technology and Engineering Center located within the Idaho National Laboratory Site. Results from monitoring perched water and groundwater at the Idaho Nuclear Technology and Engineering Center are also presented.

  2. Teaching Mass Transfer and Filtration Using Crossflow Reverse Osmosis and Nanofiltration: An Experiment for the Undergraduate Unit Operations Lab

    Science.gov (United States)

    Anastasio, Daniel; McCutcheon, Jeffrey

    2012-01-01

    A crossflow reverse osmosis (RO) system was built for a senior-level chemical engineering unit operations laboratory course. Intended to teach students mass transfer fundamentals related to membrane separations, students tested several commercial desalination membranes, measuring water flux and salt rejections at various pressures, flow rates, and…

  3. Teaching Mass Transfer and Filtration Using Crossflow Reverse Osmosis and Nanofiltration: An Experiment for the Undergraduate Unit Operations Lab

    Science.gov (United States)

    Anastasio, Daniel; McCutcheon, Jeffrey

    2012-01-01

    A crossflow reverse osmosis (RO) system was built for a senior-level chemical engineering unit operations laboratory course. Intended to teach students mass transfer fundamentals related to membrane separations, students tested several commercial desalination membranes, measuring water flux and salt rejections at various pressures, flow rates, and…

  4. Groundwater geochemical and selected volatile organic compound data, Operable Unit 1, Naval Undersea Warfare Center, Division Keyport, Washington, July 2015

    Science.gov (United States)

    Huffman, Raegan L.

    2016-05-18

    Previous investigations indicate that concentrations of chlorinated volatile organic compounds (CVOCs) are substantial in groundwater beneath the 9-acre former landfill at Operable Unit 1, Naval Undersea Warfare Center, Division Keyport, Washington. The U.S. Geological Survey has continued to monitor groundwater geochemistry to ensure that conditions remain favorable for contaminant biodegradation as specified in the Record of Decision for the site.

  5. Prevalence of Giardia duodenalis assemblages in weaned cattle on cow-calf operations in the United States

    Science.gov (United States)

    To determine the prevalence of Giardia duodenalis in weaned beef calves in cow-calf operations in the United States, fecal specimens were collected from 819 calves (6 to18 months of age) in 20 states from 49 locations. After cleaning and concentration procedures to maximize the potential recovery of...

  6. Pyrosequencing as a tool for the detection of Phytophthora species: error rate and risk of false Molecular Operational Taxonomic Units

    NARCIS (Netherlands)

    Vettraino, A.M.; Bonants, P.J.M.; Tomassini, A.; Bruni, N.; Vannini, A.

    2012-01-01

    Aims: To evaluate the accuracy of pyrosequencing for the description of Phytophthora communities in terms of taxa identification and risk of assignment for false Molecular Operational Taxonomic Units (MOTUs). Methods and Results: Pyrosequencing of Internal Transcribed Spacer 1 (ITS1) amplicons was u

  7. 78 FR 14361 - U.S. Steel Tubular Products, Inc., Mckeesport Tubular Operations Division, Subsidiary of United...

    Science.gov (United States)

    2013-03-05

    ... Employment and Training Administration U.S. Steel Tubular Products, Inc., Mckeesport Tubular Operations Division, Subsidiary of United States Steel Corporation, Mckeesport, PA; Notice of Initiation of...) filed on December 20, 2012 on behalf of workers of U.S. Steel Tubular Products, McKeesport...

  8. Remedial Design/Remedial Action Work Plan for Operable Units 6-05 and 10-04, Phase III

    Energy Technology Data Exchange (ETDEWEB)

    R. P. Wells

    2006-09-19

    The remedial design/remedial action for Operable Unit 6-05 (Waste Area Group 6) and Operable Unit 10-04 (Waste Area Group 10) - collectively called Operable Unit 10-04 has been divided into four phases. Phase I consists of developing and implementing institutional controls at Operable Unit 10-04 sites and developing and implementing Idaho National Laboratory-wide plans for both institutional controls and ecological monitoring. Phase II will remediate sites contaminated with trinitrotoluene and Royal Demolition Explosive. Phase III will remediate lead contamination at a gun range, and Phase IV will remediate hazards from unexploded ordnance. This Phase III remedial Design/Remedial Action Work Plan addresses the remediation of lead-contaminated soils found at the Security Training Facility (STF)-02 Gun Range located at the Idaho National Laboratory. Remediation of the STF-02 Gun Range will include excavating contaminated soils; physically separating copper and lead for recycling; returning separated soils below the remediation goal to the site; stabilizing contaminated soils, as required, and disposing of the separated soils that exceed the remediation goal; encapsulating and disposing of creosote-contaminated railroad ties and power poles; removing and disposing of the wooden building and asphalt pads found at the STF-02 Gun Range; sampling and analyzing soil to determine the excavation requirements; and when the remediation goals have been met, backfilling and contouring excavated areas and revegetating the affected area.

  9. US Department of Energy Nevada Operations Office annual site environmental report: 1993. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Black, S.C.; Glines, W.M.; Townsend, Y.E. [eds.

    1994-09-01

    Monitoring and surveillance on and around the Nevada Test Site (NTS) by DOE contractors and NTS user organizations during 1993 indicated that operations on the NTS were conducted in compliance with applicable federal and DOE guidelines, i.e., the dose the maximally exposed offsite individual could have received was less than 0.04 percent of the 10 mrem per year guide for air exposure. No nuclear tests were conducted due to the moratorium. All discharges of radioactive liquids remained onsite in containment ponds, and there was no indication of potential migration of radioactivity to the offsite area through groundwater. Surveillance around the NTS indicated that airborne radioactivity from diffusion, evaporation of effluents, or resuspension was not detectable offsite, and no measurable net exposure to members of the offsite population was detected through the offsite dosimetry program. Using the CAP88-PC model and NTS radionuclide emissions data, the calculated effective dose equivalent to the maximally exposed individual offsite would have been 0.004 mrem. Any person receiving this dose would also have received 97 mrem from natural background radiation. There were no nonradiological releases to the offsite area. Hazardous wastes were shipped offsite to approved disposal facilities. Compliance with the various regulations stemming from the National Environmental Policy Act is being achieved and, where mandated, permits for air and water discharges and waste management have been obtained from the appropriate agencies. Support facilities at off-NTS locations compiled with the requirements of air quality permits and state or local wastewater discharge and hazardous waste permits.

  10. Prevalence of roll-over protective structure (ROPS)-equipped tractors on Hispanic-operated farms in the United States.

    Science.gov (United States)

    Myers, John R

    2010-04-01

    Roll-over protective structures (ROPS) are known to prevent tractor overturn deaths, but not enough tractors are equipped with them in the United States to reduce the rate of these deaths to levels seen in several European countries. Recent literature has defined the use of ROPS on US farms in general, but little is known about ROPS use on Hispanic farm operations. Data from a national survey for the calendar year 2003 were used to assess the prevalence of ROPS use on Hispanic-operated farms. Farm characteristics previously identified to be associated with low ROPS prevalence rates on other farming operations were examined for these Hispanic farming operations. The overall ROPS prevalence rate on Hispanic farms was 52.2%. Adjusted odds ratios of potential risk factors found that the region where the farm was located and the acreage of the farm appeared to be the most significant indicators of the prevalence of ROPS on Hispanic farms. In addition, the age of the farm operator, the farm status as a full- or part-time operation, and the type of farm operation were also important factors. These findings were similar to those seen for racial minority farms and the general farming population. These results can be used to target ROPS promotion programs for Hispanic farmers across the United States.

  11. Operative and technological management of super-large united power grids: lessons of major world's blackouts

    Science.gov (United States)

    Brinkis, K.; Kreslins, V.; Mutule, A.

    2014-02-01

    Power system (PS) blackouts still persist worldwide, evidencing that the existing protective structures need to be improved. The discussed requirements and criteria to be met for joint synchronous operation of large and super-large united PSs should be based on close co-ordination of operative and technological management of all PSs involved in order to ensure secure and stable electricity supply and minimise or avoid the threat of a total PS blackout. The authors analyse the July 2012 India blackout - the largest power outage in history, which affected over 620 million people, i.e. half of India's population and spread across its 22 states. The analysis is of a general character, being applicable also to similar blackouts that have occurred in Europe and worldwide since 2003. The authors summarise and develop the main principles and methods of operative and technological management aimed at preventing total blackouts in large and super-large PSs. Neskatoties uz sasniegumiem elektroenerģētikas jomā un energosistēmu nepārtrauktu modernizāciju, pasaulē regulāri notiek sabrukumu avārijas. Rakstā apskatīti lielu un superlielu energosistēmu apvienību savstarpējas sinhronas darbības nodrošinājuma prasības un kritēriji, kas pamatojas uz operatīvās un tehnoloģiskās vadības ciešu koordināciju starp energosistēmām. Savstarpējas sinhronas darbības nodrošinājuma prasībām un kritērijiem ir izšķiroša nozīme, lai panāktu elektroapgādes drošumu un stabilitāti katrā energosistēmā, kas darbojas apvienotas energosistēmas sastāvā. Šo prasību un kritēriju ievērošana sekmē totālo avāriju izcelšanās iespēju samazināšanu un to novēršanu. Indijas 2012.gada totālo avāriju un citu analogo avāriju Eiropā un Amerikā analīze un izvērtējums laika posmā no 2003.gada, deva iespēju apkopot un izstrādāt lielu un superlielu energosistēmu operatīvās un tehnoloģiskās vadības principus un metodoloģiju, lai novērstu vai

  12. Global Strategy Implementation at the Business Unit Level: Operational Capabilities and Administrative Mechanisms

    OpenAIRE

    Kendall Roth; David M Schweiger; Allen J Morrison

    1991-01-01

    The study examines the impact of internationally strategy on organizational design and the influence of the organizational design on effectiveness at the business unit level. The empirical findings are based on survey responses from eighty-two business units competing in global industries. The findings are supportive of the contingency notion which suggests that business unit effectiveness is a function of the fit between the international strategy and the organizational design.© 1991 JIBS. J...

  13. Global Strategy Implementation at the Business Unit Level: Operational Capabilities and Administrative Mechanisms

    OpenAIRE

    Kendall Roth; David M Schweiger; Allen J Morrison

    1991-01-01

    The study examines the impact of internationally strategy on organizational design and the influence of the organizational design on effectiveness at the business unit level. The empirical findings are based on survey responses from eighty-two business units competing in global industries. The findings are supportive of the contingency notion which suggests that business unit effectiveness is a function of the fit between the international strategy and the organizational design.© 1991 JIBS. J...

  14. Establishment of minimum operational parameters for a high-volume static chamber steam pasteurization system (SPS 400-SC) for beef carcasses to support HACCP programs.

    Science.gov (United States)

    Retzlaff, Deanna; Phebus, Randall; Kastner, Curtis; Marsden, James

    2005-01-01

    A static chamber steam pasteurization unit (SPS 400-SC()) was installed in a high-volume commercial beef slaughter facility. The SPS 400-SC consists of a three-phase carcass treatment cycle of water removal, steam pasteurization, and water chilling. Seven chamber temperatures (71.1, 73.9, 76.7, 79.4, 82.2, 85.0, and 87.8 degrees C) were evaluated at the midline area of pre-rigor beef carcasses. For each temperature evaluated, 20 carcass sides were randomly selected and aseptically sampled by tissue excision immediately before and after steam pasteurization to determine total aerobic bacteria, Enterobacteriaceae, generic E. coli, and total coliform populations. The 87.8 and 85.0 degrees C treatment temperatures were highly effective at reducing total aerobic bacterial populations, with log(10) reductions of 1.4 and 1.5 CFU/cm(2), respectively, from pretreatment mean population levels of 1.7 and 1.9 log10 CFU/cm(2). These temperatures also reduced Enterobacteriaceae, total coliforms, and generic E. coli to undetectable levels (HACCP)-based system employing steam pasteurization of carcasses as a critical control point, a critical limit of 85.0 degrees C as a minimum chamber temperature should be established, with a targeted operating temperature of 87.8 degrees C providing optimum antimicrobial activity.

  15. Assessment of the feasibility of an improvement programme enabling operation of units 3 and 4 of Kozloduy nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Amri, A.; Aronov, J.; Bonino, F.; Cortes, P.; Gorbatchev, A.; Kanev, K.; Mattei, J.M.; Milhem, J.L.; Rollinger, F.; Sabotinov, L.; Samier, L. [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (FR). Inst. de Protection et de Securete Nucleaire (IPSN)

    2001-07-01

    Since ten years, different western assessments have been made of the safety of VVER 440/230 units, including those of the KOZLODUY Nuclear Power Plant located in Bulgaria. Concerning the latter, reference can be made to the work of an European Consortium (GRS/Germany, IPSN/France, AEA/England, AVN/ Belgium), in 1992 and 1993, during examination of restart conditions for Units 1 and 2. The objective of these assessments was the improvement of the overall level of safety with a view to maintain these units in service with satisfactory safety level for a limited period. The work identified their main deficiencies. At the present time, all the modifications decided upon for Units 1 and 2 of the KOZLODUY Nuclear Power Plant in 1992 and 1993 have been adopted and implemented for Units 3 and 4. In 1999, considering that these units would probably not be definitively shutdown before about ten years, IPSN decided to perform an internal assessment of the feasibility of an improvement programme enabling continued operation of units 3 and 4 of KOZLODUY Nuclear Power Plant during this delay. (orig.)

  16. Record of Decision for Tank Farm Soil and INTEC Groundwater, Operable Unit 3-14

    Energy Technology Data Exchange (ETDEWEB)

    L. S. Cahn

    2007-05-16

    This decision document presents the selected remedy for Operable Unit (OU) 3-14 tank farm soil and groundwater at the Idaho Nuclear Technology and Engineering Center (INTEC), which is located on the Idaho National Laboratory (INL) Site. The tank farm was initially evaluated in the OU 3-13 Record of Decision (ROD), and it was determined that additional information was needed to make a final decision. Additional information has been obtained on the nature and extent of contamination in the tank farm and on the impact to groundwater. The selected remedy was chosen in accordance with the Comprehensive Environmental Response, Liability and Compensation Act of 1980 (CERCLA) (42 USC 9601 et seq.), as amended by the Superfund Amendments and Reauthorization Act of 1986 (Public Law 99-499) and the National Oil and Hazardous Substances Pollution Contingency Plan (40 CFR 300). The selected remedy is intended to be the final action for tank farm soil and groundwater at INTEC. The response action selected in this ROD is necessary to protect the public health, welfare, or the environment from actual or threatened releases of hazardous substances into the environment. Such a release or threat of release may present an imminent and substantial endangerment to public health, welfare, or the environment. The remedial actions selected in this ROD are designed to reduce the potential threats to human health and the environment to acceptable levels. In addition, DOE-ID, EPA, and DEQ (the Agencies) have determined that no action is necessary under CERCLA to protect public health, welfare, or the environment at 16 sites located outside the tank farm boundary. The purposes of the selected remedy are to (1) contain contaminated soil as the radionuclides decay in place, (2) isolate current and future workers and biological receptors from contact with contaminated soil, and (3) restore the portion of Snake River Plain Aquifer contaminated by INTEC releases to Idaho Ground Water Quality

  17. BIOTIC INTEGRITY OF STREAMS IN THE SAVANNAH RIVER SITE INTEGRATOR OPERABLE UNITS, 1996 TO 2003

    Energy Technology Data Exchange (ETDEWEB)

    Paller, M; Susan Dyer, S

    2004-11-08

    The Savannah River Site (SRS) has been divided into six Integrator Operable Units (IOUs) that correspond to the watersheds of the five major streams on the SRS (Upper Three Runs, Fourmile Branch, Pen Branch, Steel Creek, and Lower Three Runs) and the portions of the Savannah River and Savannah River Swamp associated with the SRS. The streams are the primary integrators within each IOU because they potentially receive, through surface or subsurface drainage, soluble contaminants from all waste sites within their watersheds. If these contaminants reach biologically significant levels, they would be expected to effect the numbers, types, and health of stream organisms. In this study, biological sampling was conducted within each IOU as a measure of the cumulative ecological effects of the waste sites within the IOUs. The use of information from biological sampling to assess environmental quality is often termed bioassessment. The IOU bioassessment program included 38 sites in SRS streams and nine sites in the Savannah River. Sampling was conducted in 1996 to 1998, 2000, and 2003. Four bioassessment methods were used to evaluate ecological conditions in the IOU streams: the Index of Biotic Integrity, the Fish Health Assessment Index, measurement of fish tissue contaminant levels, and two benthic macroinvertebrate indices. The Index of Biotic Integrity (IBI) is an EPA supported method based on comparison of ecologically important and sensitive fish assemblage variables between potentially disturbed and reference (i.e., undisturbed) sites. It is designed to assess the ability of a stream to support a self-sustaining biological community and ecological processes typical of undisturbed, natural conditions. Since many types of contaminants can bioaccumulate, fish tissue contaminant data were used to determine the types of chemicals fish were exposed to and their relative magnitudes among IOUs. The Fish Health Assessment Index (HAI) is an EPA supported method for assessing

  18. U.S. Job Creation Due to Nuclear Power Resurgence in The United States — Volumes 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Catherine M. Plowman

    2004-11-01

    The recent revival of interest in nuclear power is causing a reexamination of the role of nuclear power in the United States. This renewed interest has led to questions regarding the capability and capacity of current U.S. industries to support a renewal of nuclear power plant deployment. This study was conducted to provide an initial estimate of jobs to be gained in the U.S. through the repatriation of the nuclear manufacturing industry. In the course of the study, related job categories were also modeled to provide an additional estimate of the potential expansion of existing industries (i.e., plant construction and operations) in conjunction with the repatriation of manufacturing jobs.

  19. Critical evaluation of the nonradiological environmental technical specifications. Volume 4. San Onofre Nuclear Generating Station, Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S.M.; Cunningham, P.A.; Gray, D.D.; Kumar, K.D.

    1976-08-10

    A comprehensive study of the data collected as part of the environmental Technical Specifications program for Unit 1 of the San Onofre Nuclear Generating Station (SONGS 1) was conducted for the Office of Nuclear Regulatory Research of the U.S. Nuclear Regulatory Commission. The program included an analysis of the hydrothermal and ecological monitoring data collected during 1975. The hydrothermal analysis includes a discussion of models used in plume predictions prior to plant operation and an evaluation of the present hydrothermal monitoring program. The ecological evaluation was directed toward reviewing the strengths and weaknesses of the various sampling programs designed to monitor the planktonic, benthic, and nektonic communities inhabiting the inshore coastal area in the vicinity of San Onofre.

  20. The influence of volume and intensive care unit organization on hospital mortality in patients admitted with severe sepsis: a retrospective multicentre cohort study.

    NARCIS (Netherlands)

    Peelen, L.; Keizer, N.F. de; Peek, N.; Scheffer, G.J.; Voort, P.H. van der; Jonge, E. de

    2007-01-01

    INTRODUCTION: The aim of the study was to assess the influence of annual volume and factors related to intensive care unit (ICU) organization on in-hospital mortality among patients admitted to the ICU with severe sepsis. METHODS: A retrospective cohort study was conducted using the database of the